WorldWideScience

Sample records for anterior lens capsule

  1. Herniation of the anterior lens capsule

    Directory of Open Access Journals (Sweden)

    Pereira Nolette

    2007-01-01

    Full Text Available Herniation of the anterior lens capsule is a rare abnormality in which the capsule bulges forward in the pupillary area. This herniation can be mistaken for an anterior lenticonus where both the capsule and the cortex bulge forward. The exact pathology behind this finding is still unclear. We report the clinical, ultrasound biomicroscopy (UBM and histopathological findings of a case of herniation of the anterior lens capsule. UBM helped to differentiate this entity from anterior lenticonus. Light microscopy revealed capsular splitting suggestive of capsular delamination and collection of fluid (aqueous in the area of herniation giving it a characteristic appearance.

  2. Perforation forces of the intact porcine anterior lens capsule.

    Science.gov (United States)

    Ullrich, Franziska; Lussi, Jonas; Felekis, Dimitrios; Michels, Stephan; Petruska, Andrew J; Nelson, Bradley J

    2016-09-01

    During the first step of cataract surgery, the lens capsule is perforated and a circular hole is created with a sharp instrument, a procedure called capsulorhexis. To develop automated systems that can assist ophthalmologists during capsulorhexis, the forces required must be quantified. This study investigates perforation forces of the central anterior lens capsule in porcine eyes, which are used as a conservative model for the human eye. A micro-mechanical characterisation method is presented that measures capsular bag perforation forces with a high precision positioning and high-resolution force sensing system. The force during perforation of the anterior lens capsule was measured with various sized needles and indentation speeds and is found to be 15-35mN. A bio-mechanical model is identified that describes an exponential correlation between indentation force and depth, indicating strain hardening behaviour of the porcine anterior lens capsule. PMID:27254279

  3. Perforation forces of the intact porcine anterior lens capsule.

    Science.gov (United States)

    Ullrich, Franziska; Lussi, Jonas; Felekis, Dimitrios; Michels, Stephan; Petruska, Andrew J; Nelson, Bradley J

    2016-09-01

    During the first step of cataract surgery, the lens capsule is perforated and a circular hole is created with a sharp instrument, a procedure called capsulorhexis. To develop automated systems that can assist ophthalmologists during capsulorhexis, the forces required must be quantified. This study investigates perforation forces of the central anterior lens capsule in porcine eyes, which are used as a conservative model for the human eye. A micro-mechanical characterisation method is presented that measures capsular bag perforation forces with a high precision positioning and high-resolution force sensing system. The force during perforation of the anterior lens capsule was measured with various sized needles and indentation speeds and is found to be 15-35mN. A bio-mechanical model is identified that describes an exponential correlation between indentation force and depth, indicating strain hardening behaviour of the porcine anterior lens capsule.

  4. Silicone Oil Tamponade Combined with Lensectomy Preserving Anterior Lens Capsule

    Institute of Scientific and Technical Information of China (English)

    LuL; YangJ

    1999-01-01

    Purpose:To investigate the therapeutic effect and indicatio n of silicone oil tamponade combined with lensectomy preserving anterior lens capsule.Methods:Silicone oil tamponade combined with lensectomy preserving anterior lens capsule was performed in 33 cases (33 eyes)of high myopia ,proliferative vitroretinopathy(PVR)D grade and giant retinal tear(GRT).10 cases were onlyeye and 11 cases had harder nucleus of lens.The surgical methods included:1.smashing lens nucleus and lensectomy preserving complete anterior capsule;2,vitrectomy and membrane peeling;3,usage of liquid perfluorocarbin or retinotomy or drainage;4.silicone oil tamponade;5.postoperative Nd;YAG laser for anterior capsulectomy. Results:Follow-up time was 6 months or more in 29 cases.Total retinal reattachment was achieved in 22 cases,macular retinal reattachment in 5 cases.The visual acuity was 20/800 to 20/200 in 13 cases,20/100 to 20/50 in 12 cases.Visual acuity was significantly improved in GRT group(P<0.05).Complications included unexpected anterior capsule break intraoperatively,anterior capsule opacity,silicone oil emulsification and liquid perfluorocarbin remainig postoperatively.Conclusions:Silicone oil tamponade combined with lensectomy preserving anterior capsule was safe and can reduce the operative complications.The indications included:1.GRT complicated with high myopia;2,advanced PVR cases complicated with high myopia in which silicone oil must be used;3.severe lens opacity cases in which silicone oil must be used;4.complex retinal detachment of only ye.

  5. THICKENING AND MULTILAMELLAR APPEARANCE OF THE ANTERIOR LENS CAPSULE AND RELATED FACTORS

    OpenAIRE

    Kazuo Tsutsui; Yosmaki Nawa; Sachiko Uemura; Mitsuo Tsukamoto; Toshio Shimizu; Masaya Kominami; Yoshiaki Hara

    2004-01-01

    The purpose of this study was to investigate which factors (including age, sex, grade of cataract, diabetes mellitus (DM), pseudoexfoliation, glaucoma, and atopy) are correlated with thickening and/or multilamellar appearance of the anterior lens capsule. Seventy-two anterior lens capsules were obtained during cataract surgeries. They were fixed, embedded in paraffin, and stained with Periodic acid-Schiff (PAS) and Masson-Trichrome. We measured thickness of the anterior capsules on microscopi...

  6. A case of phacolytic glaucoma with anterior lens capsule disruption identified by scanning electron microscopy

    OpenAIRE

    Yoo, Woong-Sun; Kim, Byeong-Jae; Chung, In-Young; Seo, Seong-Wook; Yoo, Ji-Myong; Kim, Seong-Jae

    2014-01-01

    Background Phacolytic glaucoma is induced by lens protein or macrophages that have leaked through a macroscopically intact anterior lens capsule. Here, we report a case of phacolytic glaucoma with anterior lens capsule disruptions visualized by scanning electron microscopy (SEM). Case presentation A 71-year-old man was referred to our institute for increased intraocular pressure (IOP) in the right eye. Slit-lamp biomicroscopic examination revealed corneal edema, the presence of inflammatory c...

  7. Treatment Approach to Small Inadvertent Injury of the Crystalline Lens Anterior Capsule During Iridodialysis Repair Surgery

    Directory of Open Access Journals (Sweden)

    Gökçen Gökçe

    2013-01-01

    Full Text Available A 22-year-old man presented to our ophthalmology department with photophobia. On ophthalmic examination, iridodialysis secondary to blunt trauma that occurred 5 years ago was diagnosed. During iridodialysis repair surgery, long curved double-armed needle of 10-0 polypropylene suture (PC-9 inserted into the 19 gauge side port turned down inadvertently by its own weight, resulting in crystalline lens anterior capsule perforation. Postoperative clinical observation revealed no lens opacification affecting visual acuity. This case report showed that lens aspiration surgery should be postponed if the capsule injury is small.(Turk J Ophthalmol 2013; 43: 61-3

  8. Measurements of elastic modulus for human anterior lens capsule with atomic force microscopy: the effect of loading force.

    Science.gov (United States)

    Tsaousis, Konstantinos T; Karagiannidis, Panagiotis G; Kopsachilis, Nikolaos; Symeonidis, Chrysanthos; Tsinopoulos, Ioannis T; Karagkiozaki, Varvara; Lamprogiannis, Lampros P; Logothetidis, Stergios

    2014-06-01

    The purpose of the study was to appraise the effect of loading force magnitude on the determination of the elastic modulus of the anterior lens capsule through atomic force microscopy. Four human anterior lens capsules taken during phacoemulsification cataract surgery were studied, free of epithelial cells, with atomic force microscopy. For the experiment, five different indentation loading forces were applied to near areas of the specimen. Experimental data was exported and analyzed according to the Hertz model to obtain the Young's modulus with regards to the elastic behavior of the material. Force-distance curves were acquired by applying a load of 2, 5, 10, 20 and 30 nN. When examining the results it was evident that determination of Young's modulus of the anterior lens capsule is dependent on the loading force concerning the examined range. Loading forces of 10 and 20 nN led to results without significant difference (p > 0.05) and more reproducible (coefficients of variation 12.4 and 11.7 %, respectively). PMID:24037592

  9. Restoring lens capsule integrity enhances lens regeneration in New Zealand albino rabbits and cats.

    Science.gov (United States)

    Gwon, A; Gruber, L J; Mantras, C

    1993-11-01

    In studies conducted by numerous investigators for 150 years, lenses regenerated following endocapsular lens extraction in New Zealand albino rabbits have been irregular in shape, appearing primarily doughnut-shaped as a result of lack of lens growth at the site of the anterior capsulotomy and its adhesion to the posterior capsule. In the present study, we restored the lens capsule integrity by inserting a collagen patch at the time of surgery to seal the anterior capsulotomy and to improve the shape and structure of the regenerated lenses. We then filled the capsule bag with air to prevent adhesions between the anterior and posterior capsule and maintain capsule tautness and shape. Lens regeneration was first noted as early as one to two weeks. Regenerated lens filled approximately 50% of the capsule bag at two weeks and 100% by five weeks. Subsequent growth was in the anterior-posterior direction and measured by A-scan biometry. Lens thickness increased by 0.3 mm per month. The regenerated lenses were spherical with normal cortical structure and a nuclear opacity. In conclusion, restoration of lens capsular integrity with a collagen patch following endocapsular lens extraction enhanced the shape, structure, and growth rate of the regenerated lenses. In addition, lens regeneration was shown to occur in two cats.

  10. The Analysis of Intracellular and Intercellular Calcium Signaling in Human Anterior Lens Capsule Epithelial Cells with Regard to Different Types and Stages of the Cataract.

    Directory of Open Access Journals (Sweden)

    Marko Gosak

    Full Text Available In this work we investigated how modifications of the Ca2+ homeostasis in anterior lens epithelial cells (LECs are associated with different types of cataract (cortical or nuclear and how the progression of the cataract (mild or moderate affects the Ca2+ signaling. We systematically analyzed different aspects of intra- and inter-cellular Ca2+ signaling in the human LECs, which are attached to surgically isolated lens capsule (LC, obtained during cataract surgery. We monitored the temporal and spatial changes in intracellular Ca2+ concentration after stimulation with acetylcholine by means of Fura-2 fluorescence captured with an inverted microscope. In our analysis we compared the features of Ca2+ signals in individual cells, synchronized activations, spatio-temporal grouping and the nature of intercellular communication between LECs. The latter was assessed by using the methodologies of the complex network theory. Our results point out that at the level of individual cells there are no significant differences when comparing the features of the signals with regard either to the type or the stage of the cataract. On the other hand, noticeable differences are observed at the multicellular level, despite inter-capsule variability. LCs associated with more developed cataracts were found to exhibit a slower collective response to stimulation, a less pronounced spatio-temporal clustering of LECs with similar signaling characteristics. The reconstructed intercellular networks were found to be sparser and more segregated than in LCs associated with mild cataracts. Moreover, we show that spontaneously active LECs often operate in localized groups with quite well aligned Ca2+ activity. The presence of spontaneous activity was also found to affect the stimulated Ca2+ responses of individual cells. Our findings indicate that the cataract progression entails the impairment of intercellular signaling thereby suggesting the functional importance of altered Ca2

  11. Noncontact optical measurement of lens capsule thickness ex vivo

    Science.gov (United States)

    Ziebarth, Noel M.; Manns, Fabrice; Uhlhorn, Stephen; Parel, Jean-Marie

    2004-07-01

    Purpose: To design a non-contact optical system to measure lens capsule thickness in cadaver eyes. Methods: The optical system uses a 670nm laser beam delivered to a single-mode fiber coupler. The output of the fiber coupler is focused onto the tissue using an aspheric lens (NA=0.68) mounted on a motorized translation stage. Light reflected from the sample is collected by the fiber coupler and sent to a silicon photodiode connected to a power meter. Peaks in the power signal are detected when the focal point of the aspheric lens coincides with the capsule boundaries. The capsule thickness is proportional to the distance between successive peaks. Anterior and posterior lens capsule thickness measurements were performed on 13 human, 10 monkey, and 34 New Zealand white rabbit lenses. The cadaver eyes were prepared for optical measurements by bonding a PMMA ring on the sclera. The posterior pole was sectioned, excess vitreous was removed, and the eye was placed on a Teflon slide. The cornea and iris were then sectioned. After the experiments, the lenses were excised, placed in 10% buffered formalin, and prepared for histology. Results: Central anterior lens capsule thickness was 9.4+/-2.9μm (human), 11.2+/-6.6μm (monkey), and 10.3+/-3.6μm (rabbit) optically and 14.9+/-1.6μm (human), 17.7+/-4.9μm (monkey), and 12.6+/-2.3μm (rabbit) histologically. The values for the central posterior capsule were 9.4+/-2.9μm (human), 6.6+/-2.5μm (monkey), and 7.9+/-2.3μm (rabbit) optically and 4.6+/-1.4μm (human), 4.5+/-1.2μm (monkey), and 5.7+/-1.7μm (rabbit) histologically. Conclusions: This study demonstrates that a non-contact optical system can successfully measure lens capsule thickness in cadaver eyes.

  12. Under-air staining of the anterior capsule using Trypan blue with a 30 G needle

    OpenAIRE

    Giammaria D; Giannotti M; Scopelliti A; Pellegrini G; Giannotti B

    2013-01-01

    Daniele Giammaria,1 Michele Giannotti,2 Angelo Scopelliti,1 Giacomo Pellegrini,1 Bruno Giannotti11Azienda Ospedaliera Ospedali Riuniti Marche Nord, Fano, Italy; 2Catholic University of Rome, Rome, ItalyAbstract: The original technique of staining the anterior capsule of the lens with Trypan blue involves the injection of an air bubble in the anterior chamber. A drawback of this technique is the possible instability of the anterior chamber caused by the sudden exit of air when the dye is injec...

  13. Under-air staining of the anterior capsule using Trypan blue with a 30 G needle

    Science.gov (United States)

    Giammaria, Daniele; Giannotti, Michele; Scopelliti, Angelo; Pellegrini, Giacomo; Giannotti, Bruno

    2013-01-01

    The original technique of staining the anterior capsule of the lens with Trypan blue involves the injection of an air bubble in the anterior chamber. A drawback of this technique is the possible instability of the anterior chamber caused by the sudden exit of air when the dye is injected with the cannula through the side-port incision. Other staining techniques that use viscoelastic substances to increase the stability of the anterior chamber and to dose the injected dye have been described. The authors present an under-air staining technique of the anterior capsule using one drop of Trypan blue injected with a 30 G needle through the peripheral cornea. This procedure prevents the air bubble from escaping the anterior chamber and allows fast and selective staining of the capsule. PMID:23386783

  14. Anterior capsule tear after laser iridotomy complicating phacoemulsification

    OpenAIRE

    Vivien Cherng Hui, Yip; Sanjay, Srinivasan; Benjamin Chong-Ming, Chang

    2011-01-01

    A 70-year-old Indian lady had a history of bilateral laser peripheral iridotomy (LPI) for primary angle closure. Subsequently she developed cataract in both the eyes. Right eye cataract surgery was complicated by an anterior capsule rupture, which was discovered intra-operatively at the site of the LPI. Trypan blue was used to stain the anterior capsule to delineate the anterior capsule defect. An attempt at continuous curvilinear capsulorhexis was unsuccessful, and the anterior capsulotomy w...

  15. Under-air staining of the anterior capsule using Trypan blue with a 30 G needle

    Directory of Open Access Journals (Sweden)

    Giammaria D

    2013-01-01

    Full Text Available Daniele Giammaria,1 Michele Giannotti,2 Angelo Scopelliti,1 Giacomo Pellegrini,1 Bruno Giannotti11Azienda Ospedaliera Ospedali Riuniti Marche Nord, Fano, Italy; 2Catholic University of Rome, Rome, ItalyAbstract: The original technique of staining the anterior capsule of the lens with Trypan blue involves the injection of an air bubble in the anterior chamber. A drawback of this technique is the possible instability of the anterior chamber caused by the sudden exit of air when the dye is injected with the cannula through the side-port incision. Other staining techniques that use viscoelastic substances to increase the stability of the anterior chamber and to dose the injected dye have been described. The authors present an under-air staining technique of the anterior capsule using one drop of Trypan blue injected with a 30 G needle through the peripheral cornea. This procedure prevents the air bubble from escaping the anterior chamber and allows fast and selective staining of the capsule.Keywords: Trypan blue, staining technique, dye, cataract surgery, capsulorhexis

  16. Misdiagnosis induced intraocular lens dislocation in anterior megalophthalmos

    Institute of Scientific and Technical Information of China (English)

    WANG Qi-wei; XU Wen; ZHU Ya-nan; LI Jin-yu; ZHANG Li; YAO Ke

    2012-01-01

    Anterior megalophthalmos (AM) is an uncommon developmental anomaly of the anterior segment of the eye with a constellation of findings that includes enlarged cornea,deep anterior chamber,posterior positioning of the iris and lens,iris stroma atrophy,hypoplasia of iris dilator,pupil displacement,large capsular bag,lens subluxation,prematurely cataract and the tendency to retinal detachment.AM,especially when symptoms are mild,is not an easy disease to diagnose.We present 3 AM cases that were misdiagnosed as congenital cataract with weak zonule and megalocornea.Intraocular lenses (IOLs) dislocated after standard cataract surgeries and subsequent surgery (replacing the dislocated IOLs with iris-claw intraocular lenses) achieved satisfactory outcome.Although rare,AM should be included in the differential diagnosis of enlarged cornea and we recommend implanting Artisan lens in AM patients.

  17. LOXL1 expression in lens capsule tissue specimens from individuals with pseudoexfoliation syndrome and glaucoma

    OpenAIRE

    Khan, Tanya T.; Li, Guorong; Navarro, Iris D.; Kastury, Rama D.; Zeil, Carol J.; Semchyshyn, Taras M.; Moya, Frank J.; Epstein, David L.; Gonzalez, Pedro; Challa, Pratap

    2010-01-01

    Purpose To study lysyl oxidase-like 1 (LOXL1) expression in freshly collected lens capsules from pseudoexfoliation syndrome (XFS), pseudoexfoliation glaucoma (XFG), and normal cataract control individuals. We also investigated the effects of four glaucoma drug medications on LOXL1 expression in primary human lens epithelial cell cultures to see if they could affect LOXL1 expression. Methods Lens capsules were collected at the time of cataract surgery. Controls were matched to age, sex, and et...

  18. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens

    Science.gov (United States)

    Spierer, Oriel; O'Brien, Terrence P.

    2016-01-01

    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful.

  19. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Oriel Spierer

    2016-05-01

    Full Text Available A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful.

  20. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens

    Science.gov (United States)

    Spierer, Oriel; O'Brien, Terrence P.

    2016-01-01

    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful. PMID:27462251

  1. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens.

    Science.gov (United States)

    Spierer, Oriel; O'Brien, Terrence P

    2016-01-01

    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful.

  2. Experimental study on cyclosporine A drug delivery system in prevention of posterior capsule opacification after intraocular lens implantation in rabbits

    Institute of Scientific and Technical Information of China (English)

    Pei Cheng; Sun Naixue

    2008-01-01

    Objective To study the effect of cyclosporine A drug delivery system (CsA-DDS) on the prevention of posterior capsule opacification (PCO) after experimental intraocular lens implantation in rabbit eyes. Methods Twenty healthy New Zealand white rabbits, whose left eyes and right eyes were used respectively as experiment eyes and controls, were subjected to extracapsular lens extraction and artificial lens implantation. During the operation, CsA-DDS with poly (lactideco-glycolide) as carriers or empty DDS was implanted in the capsular bag for the experimental eyes and controls respectively. After the operation, anterior chamber reaction, intraocular pressure (IOP) and CsA concentration were monitored and twelve weeks after the operation, the eyes were extracted for histopathological and morphological examinations. Results There were no differences between the two groups in conjunctival congestion,IOP change and anterior chamber reaction. PCO was less severe in the experimental eyes than in the controls. Light microscopy revealed that posterior capsular membrane in the experimental eyes was slick, with no obvious proliferation,whereas in the controls, there were lens epithelial cell proliferation and cortex regeneration of different degrees.Morphological examination with electron microscope showed that in the experimental eyes, lens epithelial cells did not function actively and apoptosis occurred, whereas in the controls, epithelial cells presented active function. No marked ultrastructural changes were found in either group. Conclusion Cs-DDS can inhibit PCO after intraocular lens implantation in rabbit eyes and does not have toxic effects on the surrounding ocular tissues. Therefore, it has a good potential for clinical use in prevention of PCO.

  3. Capsule Contraction Syndrome with a Microincision Foldable Hydrophilic Acrylic Intraocular Lens: Two Case Reports and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Angelo Balestrazzi

    2014-10-01

    Full Text Available Here we present 2 cases of capsule contraction syndrome (CCS. In both cases, a hydrophilic acrylic Akreos MI60 (Bausch and Lomb intraocular lens (IOL was implanted in the capsular bag through microincision cataract surgery, and the literature on the subject is reviewed. Since CCS has been described after the implantation of every IOL type, it is unlikely that the Akreos MI60 chemical and physical properties may cause CCS. When CCS occurs with IOLs composed of increasingly flexible materials that are inserted through incisions of decreasing size, a severe dislocation and deformation of IOL optics and haptics may develop. In both cases illustrated here, Nd:YAG laser anterior capsulotomy was highly effective. Hence, also based on the literature, which reports severe complications as a result of surgical intervention, it is suggested that Nd:YAG laser anterior capsulotomy be the first line of CCS treatment when the luxation of an IOL capsular bag is absent.

  4. Radiographic and anatomic landmarks to approach the anterior capsule in hip arthroscopy.

    Science.gov (United States)

    Salas, Antonio Porthos

    2015-12-01

    Hip arthroscopy (HA) is considered to be a very difficult and demanding surgical procedure, special instruments, an image intensifier and a fracture table or hip distractor are required to access the hip joint, the most common and worldwide used HA technique is entering blindly to the central compartment with the use of fluoroscopy and continuous distraction; with the potential danger if performed in unskillful hands of labral penetrations, labral resections and scuffing of the femoral head cartilage. Our technique describes the arthroscopic management of femoroacetabular impingement (FAI), performing a preoperative planning using radiographic and anatomic landmarks to approach the anterior capsule without the use of fluoroscopy. Access to the hip joint is made extra-articularly from the peritrochanteric compartment palpating the greater trochanter and posteriorly penetrating the iliotibial band sliding the arthroscopic sheath and obturator from the trochanteric border to the anterior femoral neck to visualize the anterior capsule bursa and anterior capsule fibers and posteriorly following our previous landmarks perform an anterior oblique Inverted 'T' or 'H' capsulotomy with a radiofrequency wand to access the cam-type impingement and distraction is made under direct controlled arthroscopic vision. Our technique in HA aiming the anterior capsule using radiographic and anatomic landmarks is safe, reliable and reproducible in FAI with big cams, deep sockets and cases with mild arthritis where the capsule is thick, stiff and calcified. PMID:27011869

  5. Anterior iris-claw lens implantation with single paracentesis

    Directory of Open Access Journals (Sweden)

    Ahmet Özer

    2011-11-01

    Full Text Available In this study, the technique and results of iris-claw intraocular lens (IOL implantation with corneal incision and single paracentesis were presented. Eighteen eyes of 18 patients who underwent iris-claw implantation surgery with a single paracentesis were included in this prospective study. Iris-claw lens was grasped by its forceps and placed into the anterior chamber through superior corneal opening. While IOL was held by forceps, a blunt enclavation spatula was introduced through inferior paracentesis. Then the spatula was directed toward underneath of iris through pupil and toward sides where iris was entrapped into the claw by gentle push of iris through the slotted center of the lens haptics. Mean age of patients was 54.28±25.21 years (7-76 years. Mean anterior chamber depth was 4.07±0.32 mm and mean keratometric power was 43.01±2.73 D. Preoperative BCVA was 20/63 or better in 8 (44.4% patients. At the first postoperative month BCVA was 20/63 or better in 14 (77.8% patients. Preoperative mean spherical refraction was +11.05±2.62 D, preoperative astigmatism was 2.15±0.85. Postoperative mean spherical refraction was - 0.58±0.25 D and mean astigmatism was - 1.92±0.67 D. The most frequent postoperative complication was mild corneal edema seen in three patients that resolved completely during the first week with medical treatment. Irisclaw IOL implantation can be performed easily with corneal incision and single paracentesis. Single paracentesis does not increase surgical time or cause inconvenience during the procedure.

  6. Tethered capsule OCT endomicroscopy for upper gastrointestinal tract imaging by using ball lens probe (Conference Presentation)

    Science.gov (United States)

    Dong, Jing; Gora, Michalina J.; Reddy, Rohith; Trasischker, Wolfgang; Poupart, Oriane; Lu, Weina; Carruth, Robert W.; Grant, Catriona N.; Soomro, Amna R.; Tiernan, Aubrey R.; Rosenberg, Mireille; Nishioka, Norman S.; Tearney, Guillermo J.

    2016-03-01

    While endoscopy is the most commonly used modality for diagnosing upper GI tract disease, this procedure usually requires patient sedation that increases cost and mandates its operation in specialized settings. In addition, endoscopy only visualizes tissue superfically at the macroscopic scale, which is problematic for many diseases that manifest below the surface at a microscopic scale. Our lab has previously developed technology termed tethered capsule OCT endomicroscopy (TCE) to overcome these diagnostic limitations of endoscopy. The TCE device is a swallowable capsule that contains optomechanical components that circumferentially scan the OCT beam inside the body as the pill traverses the organ via peristalsis. While we have successfully imaged ~100 patients with the TCE device, the optics of our current device have many elements and are complex, comprising a glass ferrule, optical fiber, glass spacer, GRIN lens and prism. As we scale up manufacturing of this device for clinical translation, we must decrease the cost and improve the manufacturability of the capsule's optical configuration. In this abstract, we report on the design and development of simplificed TCE optics that replace the GRIN lens-based configuration with an angle-polished ball lens design. The new optics include a single mode optical fiber, a glass spacer and an angle polished ball lens, that are all fusion spliced together. The ball lens capsule has resolutions that are comparable with those of our previous GRIN lens configuration (30µm (lateral) × 7 µm (axial)). Results in human subjects show that OCT-based TCE using the ball lens not only provides rapid, high quality microstructural images of upper GI tract, but also makes it possible to implement this technology inexpensively and on a larger scale.

  7. MORPHOLOGICAL ASPECTS OF HUMAN LENS CAPSULES - A COMPARATIVE LM, SEM AND TEM EXAMINATION

    NARCIS (Netherlands)

    JONGEBLOED, WL; KALICHARAN, D; LOS, LI; VANDERVEEN, G; WORST, JGF

    1991-01-01

    Lens capsules of patients of advanced age, obtained after extracapsular cataract surgery, were carefully prepared for a combined LM, TEM and SEM investigation, after preliminary washing and mounting onto a holder in a buffer solution. After pre-fixation with GA, samples were postfixed for LM/TEM and

  8. Anterior Chamber Iris Claw Lens for the Treatment of Aphakia in a Patient with Megalocornea

    Science.gov (United States)

    Saffra, Norman; Rakhamimov, Aleksandr; Masini, Robert; Rosenthal, Kenneth J.

    2015-01-01

    Megalocornea in isolation is a rare congenital enlargement of the cornea greater than 13 mm in diameter. Patients with megalocornea are prone to cataract formation, crystalline lens subluxation, zonular deficiencies and dislocation of the posterior chamber intraocular lens (PCIOL) within the capsular bag. A 55-year-old male with megalocornea in isolation developed subluxation of the capsular bag and PCIOL. The PCIOL and capsular bag were explanted, and the patient was subsequently implanted with an anterior chamber iris claw lens. An anterior chamber iris claw lens is an effective option for the correction of aphakia in patients with megalocornea. PMID:26120314

  9. Anterior migration of dexamethasone implant in a pseudophakic patient with intact posterior capsule

    OpenAIRE

    Nilufer Kocak; Taylan Ozturk; Eyyup Karahan; Suleyman Kaynak

    2014-01-01

    Intravitreal application of Ozurdex ® (Allergan, Inc., Irvine, CA, USA) which is a biodegradable, sustained-release dexamethasone implant has been reported to be effective in the treatment of macular edema. Migration of such implant into the anterior chamber has been recently described in cases without perfect zonular or the posterior capsular integrity. Herein, we report the first case with anterior migration of Ozurdex ® implant that mislocated just behind the intraocular lens (IOL) in an i...

  10. In-the-bag decentration of a hydrophilic radially asymmetric multifocal intraocular lens secondary to capsule contraction.

    NARCIS (Netherlands)

    Linden, J.W.M. van der; Meulen, I.J. van der; Mourits, M.P.; Lapid-Gortzak, R.

    2013-01-01

    We report a case of in-the-bag decentration and tilt of a hydrophilic rotationally asymmetric multifocal intraocular lens (IOL) of the M Plus type secondary to capsule contraction. After uneventful surgery and follow-up for 3 months, progressive decentering and tilting of the IOL secondary to capsul

  11. Experimental study on cyclosporine A drug delivery system in prevention of posterior capsule opacification after intraocular lens implantation in rabbits

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Objective To study the effect of cyclosporine A drug delivery system (CsA-DDS) on the prevention of posterior capsule opacification (PCO) after experimental intraocular lens implantation in rabbit eyes. Methods Twenty healthy New Zealand white rabbits, whose left eyes and right eyes were used respectively as experiment eyes and controls, were subjected to extracapsular lens extraction and artificial lens implantation. During the operation, CsA-DDS with poly (lactideco-glycolide) as carriers or empty DDS was...

  12. Inner Synovial Membrane Footprint of the Anterior Elbow Capsule: An Arthroscopic Boundary

    Directory of Open Access Journals (Sweden)

    Srinath Kamineni

    2015-01-01

    Full Text Available Introduction. The purpose of this study is to describe the inner synovial membrane (SM of the anterior elbow capsule, both qualitatively and quantitatively. Materials and Methods. Twenty-two cadaveric human elbows were dissected and the distal humerus and SM attachments were digitized using a digitizer. The transepicondylar line (TEL was used as the primary descriptor of various landmarks. The distance between the medial epicondyle and medial SM edge, SM apex overlying the coronoid fossa, the central SM nadir, and the apex of the SM insertion overlying the radial fossa and distance from the lateral epicondyle to lateral SM edge along the TEL were measured and further analyzed. Gender and side-to-side statistical comparisons were calculated. Results. The mean age of the subjects was 80.4 years, with six male and five female cadavers. The SM had a distinctive double arched attachment overlying the radial and coronoid fossae. No gender-based or side-to-side quantitative differences were noted. In 18 out of 22 specimens (81.8%, an infolding extension of the SM was observed overlying the medial aspect of the trochlea. The SM did not coincide with the outer fibrous attachment in any specimen. Conclusion. The humeral footprint of the synovial membrane of the anterior elbow capsule is more complex and not as capacious as commonly understood from the current literature. The synovial membrane nadir between the two anterior fossae may help to explain and hence preempt technical difficulties, a reduction in working arthroscopic volume in inflammatory and posttraumatic pathologies. This knowledge should allow the surgeon to approach this aspect of the anterior elbow compartment space with the confidence that detachment of this synovial attachment, to create working space, does not equate to breaching the capsule. Alternatively, stripping the synovial attachment from the anterior humerus does not constitute an anterior capsular release.

  13. Anterior migration of dexamethasone implant in a pseudophakic patient with intact posterior capsule

    Directory of Open Access Journals (Sweden)

    Nilufer Kocak

    2014-01-01

    Full Text Available Intravitreal application of Ozurdex ® (Allergan, Inc., Irvine, CA, USA which is a biodegradable, sustained-release dexamethasone implant has been reported to be effective in the treatment of macular edema. Migration of such implant into the anterior chamber has been recently described in cases without perfect zonular or the posterior capsular integrity. Herein, we report the first case with anterior migration of Ozurdex ® implant that mislocated just behind the intraocular lens (IOL in an intact capsular bag. It is thought that such implant migrated anteriorly towards into the posterior chamber through weak zonules as the present case had a medical history of uneventful phacoemulsification surgery with the implantation of posterior chamber IOL. However, the migrated implant was well tolerated since there was no sign of the corneal complication, rise in intraocular pressure, and anterior chamber reaction. Close follow-up was scheduled to find out any signs of anterior segment pathology. Meanwhile dexamethasone implant completely degraded at the 4 th month of postoperative follow-up.

  14. Fifty-year follow-up and Strampelli anterior chamber intraocular lens.

    Science.gov (United States)

    Oakley, Carmen L; Nigro, Matthew A; Vote, Brendan J

    2015-01-01

    The Strampelli anterior chamber intraocular lens was created in 1953, and was primarily used to treat myopia and aphakia. Due to the positioning of the lens, it was associated with a number of complications, and was later modified to decrease the rate of significant complications, including endothelial cell loss. This paper describes a 62-year-old man, who has had a Strampelli intraocular lens (IOL) in situ for 52 years, with relatively few complications. The case provides a framework for reflection on the significant advances in the development of IOLs since the Strampelli era. The Strampelli anterior chamber intraocular lens was created in 1953, and was primarily used to treat myopia and aphakia. Due to the positioning of the lens, it was associated with a number of complications, and was later modified to decrease the rate of significant complications, including endothelial cell loss. This paper describes a 62-year-old man, who has had a Strampelli intraocular lens (IOL) in situ for 52 years, with relatively few complications. The case provides a framework for reflection on the significant advances in the development of IOLs since the Strampelli era.

  15. Profile of collagen gene expression in the glenohumeral capsule of patients with traumatic anterior instability of the shoulder,

    Directory of Open Access Journals (Sweden)

    Paulo Santoro Belangero

    2014-12-01

    Full Text Available Objective:To evaluate the expression of the genes COL1A1, COL1A2, COL3A1 and COL5A1 in the glenohumeral capsule of patients with traumatic anterior instability of the shoulder.Methods:Samples from the glenohumeral capsule of 18 patients with traumatic anterior instability of the shoulder were evaluated. Male patients with a positive grip test and a Bankart lesion seen on magnetic resonance imaging were included. All the patients had suffered more than one episode of shoulder dislocation. Samples were collected from the injured glenohumeral capsule (anteroinferior region and from the macroscopically unaffected region (anterosuperior region of each patient. The expression of collagen genes was evaluated using the polymerase chain reaction after reverse transcription with quantitative analysis (qRT-PCR.Results:The expression of COL1A1, COL1A2 and COL3A1 did not differ between the two regions of the shoulder capsule. However, it was observed that the expression of COL5A1 was significantly lower in the anteroinferior region than in the anterosuperior region (median ± interquartile range: 0.057 ±0.052 vs. 0.155 ±0.398; p = 0.028 of the glenohumeral capsule.Conclusion:The affected region of the glenohumeral capsule in patients with shoulder instability presented reduced expression of COL5A1.

  16. Comparative study of the sectional slice of the anterior commissure and the internal capsule with its MRI images

    Institute of Scientific and Technical Information of China (English)

    WANG Dandan; MA Wenyi; Zhang Xiaoyang; YUAN Lixiang; YUAN Wu; LI Yunsheng

    2015-01-01

    Objective:The brain of 100 normal persons were performed MRI scan and image analysis. 12 adult female brain specimens fixed by formalin, were made into the thickness of 0. 5mm by celloidin embedding technique. We analyzed the anatomical position of the relationship about the anterior limb of internal capsule and the anterior commissure in eollodion-embedded plans, and then compared with the brain MRI of normal people. We also further compared the statistical differences of the internal capsule’ s volume. This research aimed to pro-vide a reliable sectional anatomic basis for the study of the central nervous system and deep brain stimulation to treat the mental neurological diseases. Results:1. Continous observation of celloid in brain slices horizontal section:Approximately 130 slices of each specimen, from the parietal lobe,the internal capsule was the typical structure"><" on the level of about 35 mm . On the level of about 41mm, the anterior commissure was"arc" through the bot-tom head of the caudate nucleus connecting the bilateral anterior limb, which located between the caudate nucleus and the lentiform nucleus. The posterior limb of internal capsule situated between the dorsal thalamus and the lenti-form nucleus on the level of about 46 mm. Coronal section:about 150 slices of per specimen, from the former lat-eral ventricle horn back,on the level of about 16 mm the anterior commissure was "arch" connecting the anterior limb. About 28 mm dimension, the interior capsule fore limb located between the caudate nucleus and the puta-men, the posterior limb of internal capsule located between the globus pallidus and the dorsal thalamus, extending down to the cerebral peduncle. Sagittal section:about 180 slices of per specimen, from the outside to the inside at the beginning of the temporal lobe, the corona radia taextends between the putamen and dorsal thalamus, and then formsthe posterior limb of the internal capsule at the level of about 21 mm. About 25 mm level

  17. Ciliary block (malignant) glaucoma after cataract extraction with lens implant treated with YAG laser capsulotomy and anterior hyaloidotomy.

    OpenAIRE

    Halkias, A; Magauran, D M; Joyce, M

    1992-01-01

    An 84-year-old woman developed high intraocular pressure with a shallow anterior chamber 2 months after an extracapsular cataract extraction with posterior chamber lens implant. The condition did not respond to peripheral iridectomy and removal of the implant but was treated successfully with YAG laser capsulotomy and anterior hyaloidotomy.

  18. Tensile mechanical and creep properties of Descemet's membrane and lens capsule.

    Science.gov (United States)

    Danielsen, Carl Christian

    2004-09-01

    Descemet's membrane (DM) and the lens capsule (LC) are two ocular basement membrane structures which in comparison with other basement membranes have exceptional thicknesses which increase with age. Both membranes are supposed to contain networks of type IV collagen and laminin linked together with nidogen/entactin and containing other glycoproteins and proteoglycans. DM is a unique basement membrane which in addition contains fine filaments of type VIII collagen arranged in a hexagonal lattice. The mechanical functions of the LC are in lens suspension and accommodation, and its mechanical properties, previously investigated, are of great interest from a surgical point of view. DM serves as an endothelial basement membrane. Otherwise, its physiological function is unknown but may be one of mechanical support, filtration, or fluid barrier. Data on the mechanical properties of DM or the supramolecular assembly of type VIII collagen are very scarce or absent. The aim of this study was to determine and compare the mechanical properties of the two ocular membranes in order to elucidate the properties of DM in the light of those of LC. The human eyes were from testamentary donors and rat, cow, and sow eyes were obtained from normal animals. The tensile mechanical properties were determined by a volume-strain procedure and creep properties by subjecting the membranes from the latter three species to a constant axial stress. In rat, cow, and sow, DM was less strained to obtain a fixed moderate stress value (0.5 MPa) and showed to be 3.4- to 5.2-fold stiffer and to attain 2.7- to 4.6-fold higher stress at a strain value of 0.10 when compared with LC. The maximal strain, stiffness and stress were found to be less than those of the LC. In humans, DM and LC showed very similar mechanical properties. The instantaneous creep of DM was found to be less than that of LC indicating a higher stiffness of DM in the axial direction. In conclusion, depending on the species, DM showed to

  19. Toxic Anterior Segment Syndrome after Foldable Artiflex Iris-Fixated Phakic Intraocular Lens Implantation

    Directory of Open Access Journals (Sweden)

    Lucien A. M. van Philips

    2011-01-01

    Full Text Available Toxic anterior segment syndrome (TASS developed in four cases after uneventful implantation of a foldable iris-fixated phakic intraocular lens (pIOL. Two cases occurred sequentially in one patient. The TASS subsided without complications in all cases after intensive topical steroid treatment. A multitude of possible causes is considered for the occurrence of these TASS cases. From the sterilization and cleaning of surgical instruments to the possibility of endotoxines in ophthalmic viscosurgical devices (OVD. These rare cases should alert the surgeon to the possibility of TASS after pIOL implantation.

  20. Iris-claw intraocular lens implantation: Anterior chamber versus retropupillary implantation

    Science.gov (United States)

    Helvacı, Sezer; Demirdüzen, Selahaddin; Öksüz, Hüseyin

    2016-01-01

    Purpose: To compare the outcomes of anterior chamber and retropupillary implantation of iris-claw Artisan intraocular lenses (IOL). Design: Prospective, randomized, single-blinded study. Patients and Methods: Forty eyes of forty aphakic patients were enrolled. Patients were randomized into two groups. Each group includes twenty patients. Group 1 received anterior chamber Artisan IOL implantation. Group 2 received retropupillary Artisan IOL implantation. Preoperative and postoperative corrected distance visual acuity (CDVA), intraocular pressure (IOP), and all complications were noted and compared at 6 months follow-up. Results: Each two groups obtained a significant improvement in CDVA (P < 0.05). Four patients in Group 1 and five patients in Group 2 had significant but nonpermanent increase at IOP values. There were one and two pupillary irregularity in Group 1 and Group 2, respectively. In one patient, a shallow and inferior located retinal detachment were encountered in anterior chamber group. Conclusions: The results were not significantly different between the two fixation techniques for iris-claw lens. The surgery procedure is dependent to surgeon experience and eye's conditions. PMID:26953023

  1. Anterior chamber fixation of a posterior chamber intraocular lens: A novel technique

    Directory of Open Access Journals (Sweden)

    A Sahap Kükner

    2014-01-01

    Full Text Available We aimed to evaluate the implantation of a posterior chamber intraocular lens (IOL in the anterior chamber (AC with the haptics passing through two iridectomies to the posterior chamber. A total of 33 eyes of 33 patients with inadequate posterior capsular support due to either previous aphakia or posterior capsular rupture during cataract extraction were included in the study. A double iridectomy was performed on all patients using a vitrectomy probe on the midperiphery of the iris. IOLs were implanted in the AC, and the haptics were passed through the iridectomies to the posterior chamber. The mean follow-up time was 25.3 months. AC hemorrhage occurred in five patients during the iridectomy procedure. Corneal edema was detected in eight of 14 patients with primary IOL insertions. Haptic dislocation was detected in only one patient. This technique may be a good alternative to scleral-fixated IOL implantation in eyes with aphakia.

  2. Anterior segment and retinal OCT imaging with simplified sample arm using focus tunable lens technology (Conference Presentation)

    Science.gov (United States)

    Grulkowski, Ireneusz; Karnowski, Karol; Ruminski, Daniel; Wojtkowski, Maciej

    2016-03-01

    Availability of the long-depth-range OCT systems enables comprehensive structural imaging of the eye and extraction of biometric parameters characterizing the entire eye. Several approaches have been developed to perform OCT imaging with extended depth ranges. In particular, current SS-OCT technology seems to be suited to visualize both anterior and posterior eye in a single measurement. The aim of this study is to demonstrate integrated anterior segment and retinal SS-OCT imaging using a single instrument, in which the sample arm is equipped with the electrically tunable lens (ETL). ETL is composed of the optical liquid confined in the space by an elastic polymer membrane. The shape of the membrane, electrically controlled by a specific ring, defines the radius of curvature of the lens surface, thus it regulates the power of the lens. ETL can be also equipped with additional offset lens to adjust the tuning range of the optical power. We characterize the operation of the tunable lens using wavefront sensing. We develop the optimized optical set-up with two adaptive operational states of the ETL in order to focus the light either on the retina or on the anterior segment of the eye. We test the performance of the set-up by utilizing whole eye phantom as the object. Finally, we perform human eye in vivo imaging using the SS-OCT instrument with versatile imaging functionality that accounts for the optics of the eye and enables dynamic control of the optical beam focus.

  3. Transplantation of allogenic anterior lens capsule to the subretinal space in pigs

    DEFF Research Database (Denmark)

    Kiilgaard, Jens Folke; Wiencke, Anne Katrine; Scherfig, Erik;

    2002-01-01

    To investigate the consequences of transplantation of a new basement membrane to the subretinal space (SRS) as a substitution of Bruch's membrane.......To investigate the consequences of transplantation of a new basement membrane to the subretinal space (SRS) as a substitution of Bruch's membrane....

  4. The anterior lens capsule used as support material in RPE cell-transplantation

    DEFF Research Database (Denmark)

    Nicolini, J; Kiilgaard, Jens Folke; Wiencke, A K;

    2000-01-01

    To investigate the use of an ocular basement membrane as support material for transplanted porcine RPE cells.......To investigate the use of an ocular basement membrane as support material for transplanted porcine RPE cells....

  5. Primary Posterior Chamber Intraocular Lens Implantation in Traumatic Cataract With Posterior Capsule Breaks

    Institute of Scientific and Technical Information of China (English)

    YupingZou; WenhuiYang

    1995-01-01

    Background:In patients with incomplete posterior capsule support,posterior chamber intraocular lenses(PC-IOLs)were implanted with both haptics transs-cleral fixation.This causes more damage to the eye and may result in more com-plications,In patients with small posterior breaks,non-fixation or single haptic fixation may be adequate.Methods:Thiry-two consecutive patients of traumatic cataract with posterior capsule breaks caused by penetrating eye trauma were retospected.Posterior chamber intraocular lenses were implanted in all these patients with three tech-niques,ie,without fixation,with single haptic fixation and with both haptics fixation .The selection of the technique was based on the position and size of the posterior capsule.The follow-up period was 21days to 28months(mean,15.2months).Results:Intra-operative problems included ciliary body bleeding(Two patents,6.25%)and enlargement of posterior capsule breaks(2patients,6.25).Postoperative visual acuity was0.5or better(Corrected)in28case(87.5%)and 0.1-0.4in four patients(12.5%),Postoperative complications included hyphema(6eyes,18.8%),transient intraocular pressure elevation(6eyes,18.8%),transient hypotention(7eyes,21.8%).Postoperative IOL position were good except one case of IOL tilt.No pupillary capture or endophthalmitis was found.Conclusions:Not all PC-IOLs have to be fixed by two haptics.In patients with small posterior capsule breaks,PC-IOLmay not be fixed or fixed by only one haptics.Eye Science1995;11:140-142.

  6. Lens regeneration in juvenile and adult rabbits measured by image analysis.

    Science.gov (United States)

    Gwon, A E; Jones, R L; Gruber, L J; Mantras, C

    1992-06-01

    Secondary cataract growth commonly occurs after extracapsular cataract extraction. The proliferation of this regrowth occurs at rates related to many factors. In this study, the authors analyzed the amount of lens regeneration after endocapsular lens extraction that leaves the anterior and posterior capsules relatively intact. The analysis was performed in New Zealand albino rabbits with the aid of image analysis measurements in young and adult animals. The effect of low vacuum suction of the anterior capsule on the growth was determined. Lens regeneration was used as a measure of the growth potential of the leftover epithelial cells in the capsule bag. The results showed that lens regeneration was significantly faster in younger rabbits. However, low vacuum suction had no effect on the growth rate. Potential therapeutic agents for preventing secondary cataracts may be better analyzed with image analysis processing of lens regeneration, a precise and rapid measurement technique.

  7. Incidence of posterior capsule opacification following the implantation of a foldable hydrophilic acrylic intraocular lens: a 4 year follow-up study

    OpenAIRE

    Priscilla de Almeida Jorge; Delano Jorge; Camila Vieira Ventura; Bruna Vieira Ventura; Wagner lira; Marcelo Carvalho Ventura; Marcony Rodrigues de Santhiago; Newton Kara-Junior

    2014-01-01

    Purpose: To evaluate the incidence of posterior capsule opacification (PCO) four years after the implantation of a hydrophilic acrylic intraocular lens (IOL). Methods: Fifty-eight randomly selected eyes from 58 patients were analyzed four years after phacoemulsification and Ioflex IOL implantation. The patients underwent an ophthalmic examination to detect PCO and a detailed medical history was obtained. The patients' charts were reviewed for their corrected distance visual acuity prior to ...

  8. The Effect of Phacoemulsification with Posterior Chamber Intraocular Lens Implantation on Intraocular Pressure and Anterior Chamber Depth

    Directory of Open Access Journals (Sweden)

    Mohammad Javad Mohamadi

    2013-12-01

    Full Text Available Purpose: To evaluate intraocular pressure (IOP and anterior chamber depth (ACD change after phacoemulsification with posterior chamber intraocular lens implantation Methods: In this quasi-experimental study, 84 patients with senile cataract were included. All patients had normal IOP. Patients with traumatic and complicated cataract, any history of uveitis, glaucoma, or other ocular disease or surgery were excluded. Patients underwent phacoemulsification and intraocular lens implantation by the same surgeon. IOP, ACD, and lens thickness were measured and recorded before surgery. IOP was measured at 4, 8 and 12 postoperative weeks and ACD was measured 12 weeks after surgery. Results: The mean preoperative ACD significantly increased from 2.93 mm to 3.54 mm postoperatively (p<0.0001. Mean preoperative IOP was 16.06 mmHg which decreased to 12.01 IOP mmHg, 12.57 mmHg and 12.90 mmHg at 4 weeks, 8 weeks and 12 weeks postoperatively, respectively (all p-values<0.0001. There was a correlation between lens thickness and changes of and ACD after the surgery. There was also a positive correlation between preoperative IOP and IOP reduction after the surgery. Conclusion: Phacoemulsification decreases IOP specially in eyes with higher preoperative IOP and thicker lenses.

  9. Anterior chamber depth and lens thickness in primary angle-closure glaucoma : A case-control study

    Directory of Open Access Journals (Sweden)

    Saxena Sandeep

    1993-01-01

    Full Text Available Anterior chamber depth and lens thickness have been considered as important biometric determinants in primary angle-closure glaucoma (PACG. In a tertiary care centre-based case-control study, 70 patients and equal number of controls were investigated to analyse the strength of association and predictability of anterior chamber depth (ACD and lens thickness (LT in the disease. Mean (+/- S.D. ACD and LT in the cases and the controls were found to be 2.28 +/- 0.19, 2.87 +/- 0.10; 4.57 +/- 0.34 and 4.13 +/- 0.19 mm respectively. Two sample t test demonstrated statistically significant difference in the ACD and LT between the cases and the controls (Difference being -0.59, 0.44; 95% confidence interval of the difference: -0.64, -0.53 and 0.34, 0.53 respectively, P < 0.01. Logistic regression analysis demonstrated statistically significant protective effect of ACD over PACG (P < 0.01. The odds ratio corresponding to an increase of 0.01 mm in ACD and LT were computed as 0.83 and 1.11 respectively

  10. Doenças do segmento anterior ocular associadas a lentes de contato Contact lens-associated ocular anterior segment diseases

    Directory of Open Access Journals (Sweden)

    Murilo Barreto Souza

    2008-12-01

    Full Text Available A disponibilidade de lentes de contato cada vez mais confortáveis e toleráveis favoreceu não só a ampliação das indicações, mas também o aumento do número de seus usuários. Como conseqüência deste fato as complicações associadas ao uso de lentes de contato são cada vez mais comuns, e representam um problema de grande prevalência na prática clínica. O objetivo deste estudo é revisar as principais doenças e alterações do segmento anterior e superfície ocular associadas ao uso de lentes de contato.Nowadays, contact lenses have shown a larger variety of options in order to meet the needs of different patients. They have become more frequent in the clinical practice and, consequently, the complications related to contact lenses have been more common. This review attempted to describe the main alterations and diseases of the cornea and anterior segment associated with contact lens wearers.

  11. Nd:YAG Laser Lysis of the Fibrinous Membrane and Remnant Substance on the Anterior Surface of Intraocular Lens

    Institute of Scientific and Technical Information of China (English)

    ZhendeLin; ChenjinJin

    1995-01-01

    Purpose:To determine the effects of ND:YAGlaser to disrupt the fibrinous membrane and remnant substance on the anterior surface of intraocular lens.Methods:Nd:YAGlaser was applied on 23cases of fibrinous membrane forma-tion and 8cases of remnant substance on the anterior surface of intaocular lenses(IOL)which had not reponded well to steroid therapy,Eighteen cases were male and 13female.The mean age was49.7years(range,5-78years),The in-terval between IOL implantation and laser therapy was 0.5-30months in the fibrinous membrane cases and 3-10days in the remnant substance cases.The energy applied was0.8-3.0mJ/exp.with2-112exposures.mean follow-up period was3.6months.Results:Complications during therapy included only 2cases of slight iris bleed-ing,Visual acuity after therapy was improved 1line in 16cases,2lines in 11cas-es,3lines in 1case,4lines in 1case and 5lines in 2cases,No post-therapy com-plication was found.Conclusions:Nd:YAG laser lysis is an effective alternative to ramove the fibri-nous membrane and remnant substances on the anterior surface of IOL.Eye Sci-ence1995;11:128-130.

  12. Anterior limb of the internal capsule in schizotypal personality disorder: fiber-tract counting, volume, and anisotropy.

    Science.gov (United States)

    Hazlett, Erin A; Collazo, Tyson; Zelmanova, Yuliya; Entis, Jonathan J; Chu, King-Wai; Goldstein, Kim E; Roussos, Panos; Haznedar, M Mehmet; Koenigsberg, Harold W; New, Antonia S; Buchsbaum, Monte S; Hershowitz, Julian P; Siever, Larry J; Byne, William

    2012-11-01

    Mounting evidence suggests that white matter abnormalities and altered subcortical-cortical connectivity may be central to the pathology of schizophrenia (SZ). The anterior limb of the internal capsule (ALIC) is an important thalamo-frontal white-matter tract shown to have volume reductions in SZ and to a lesser degree in schizotypal personality disorder (SPD). While fractional anisotropy (FA) and connectivity abnormalities in the ALIC have been reported in SZ, they have not been examined in SPD. In the current study, magnetic resonance (MRI) and diffusion tensor imaging (DTI) were obtained in age- and sex-matched individuals with SPD (n=33) and healthy controls (HCs; n=38). The ALIC was traced bilaterally on five equally spaced dorsal-to-ventral axial slices from each participant's MRI scan and co-registered to DTI for the calculation of FA. Tractography was used to examine tracts between the ALIC and two key Brodmann areas (BAs; BA10, BA45) within the dorsolateral prefrontal cortex (DLPFC). Compared with HCs, the SPD participants exhibited (a) smaller relative volume at the mid-ventral ALIC slice level but not the other levels; (b) normal FA within the ALIC; (c) fewer relative number of tracts between the most-dorsal ALIC levels and BA10 but not BA45 and (d) fewer dorsal ALIC-DLPFC tracts were associated with greater symptom severity in SPD. In contrast to prior SZ studies that report lower FA, individuals with SPD show sparing. Our findings are consistent with a pattern of milder thalamo-frontal dysconnectivity in SPD than schizophrenia.

  13. Iris-fixated anterior chamber phakic intraocular lens for myopia moves posteriorly with mydriasis.

    NARCIS (Netherlands)

    Cruysberg, L.P.J.; Doors, M.; Berendschot, T.T.; Brabander, J. De; Webers, C.A.; Nuijts, R.M.

    2009-01-01

    PURPOSE: To elucidate the physiological characteristics of eyes implanted with iris-fixated anterior chamber phakic intraocular lenses (pIOLs), which are increasingly being used for the correction of higher myopic and hyperopic refractive errors. METHODS: In a case series of 20 patients (39 eyes), t

  14. Effect of anterior chamber depth on the choice of intraocular lens calculation formula in patients with normal axial length

    Directory of Open Access Journals (Sweden)

    Mohammad Miraftab

    2014-01-01

    Full Text Available Purpose: To compare the accuracy of  Sanders-Retzlaff-Kraff II (SRK II and 3 rd and 4 th generation intraocular lens (IOL formulas and to compare the effect of different anterior chamber depths among the IOL formulas in cataract patients with normal axial length (AL; 22.0-24.5 millimeters, mm. Materials and Methods: A retrospective chart review was performed of patients with normal AL who underwent cataract surgery. The SRK II and 3 rd generation IOL formulas (Hoffer Q, SRK T, Holladay 1 were compared to the 4 th generation Haigis formula. For analysis, preoperative anterior chamber depth (ACD was divided into three subgroups: ≤3, 3-3.5, and ≥ 3.5 mm. The mean error (ME and mean absolute error (MAE of each formula was compared for each subgroup against the total. The difference between the ME and MAE of the formulas were compared for each ACD subgroup. P 0.05, all comparisons. Conclusion: The SRK II formula can predict refraction in patients with normal AL and ACD less than 3 mm with less error and is preferred over other formulas. The Haigis formula is the preferred choice in patients with a normal AL and ACD longer than 3.5 mm. The prediction accuracy of Hoffer Q, SRK T, and Holladay 1 is comparable in normal AL.

  15. Comparison of posterior capsule opacification at 360-degree square edge hydrophilic and sharp edge hydrophobic acrylic intraocular lens in diabetic patients

    Institute of Scientific and Technical Information of China (English)

    Ling; Bai; Jin; Zhang; Ling; Chen; Ting; Ma; Hou-Cheng; Liang

    2015-01-01

    ·AIM: To compare posterior capsule opacification(PCO)degree and visual functions after phacoemulsification in eyes implanted with 360-degree square edge hydrophilic acrylic intraocular lens(IOL)(570C C-flex, Rayner) and sharp edge hydrophobic acrylic IOL(Sensar AR40 e,AMO) in diabetic patients.· METHODS: Sixty diabetic patients underwent uneventful phacoemulsification and randomly implanted one of the two IOLs. The PCO value was measured by retroillumination photographs and Evaluation of Posterior Capsule Opacification(EPCO) 2000 image-analysis software at 1, 6, 12, and 24 mo after surgery. Visual acuity, and contrast sensitivity in photopic and mesopic conditions were also examined at each follow up time point. The incidence of eye that required Nd:YAG laser posterior capsulotomy were also compared.·RESULTS: There was not any statistically significant difference in PCO scores between Rayner C-flex 570 C group and Sensar AR40 e group at each follow up time point. Visual acuity, Nd:YAG capsulotomy incidence and contrast sensitivity also had no significant difference during the 24 mo follow-up.·CONCLUSION: For diabetic patients, Rayner 570 C Cflex and Sensar AR40 e IOLs are same effective for prevent PCO. The 360-degree square edge design maybe is a good alternative technique to improve PCO prevention.

  16. Cataract Surgery for Tilted Lens in Peters' Anomaly Type 2

    Directory of Open Access Journals (Sweden)

    Tadayuki Nishide

    2013-09-01

    Full Text Available Background: Cases of cataract surgery without penetrating keratoplasty in patients with Peters' anomaly are very rare. We report a case of Peters' anomaly type 2 with tilted lens due to synechia between the lens and iris that was treated with cataract surgery without penetrating keratoplasty. Case Presentation: A 16-year-old girl had Peters' anomaly in both eyes. Corneal opacity was severe in the left eye due to high-grade dysgenesis of the anterior segment. In the right eye, corneal opacity had spread from the center of the cornea to the inferotemporal side, and there was synechia between the iris and corneal endothelium from the inferonasal side to the inferotemporal side. Opacity was observed in the anterior pole of the lens, and there was synechia between the anterior iris and the lens. Ultrasound biomicroscopy (UBM revealed that the lens was tilted because of synechia. The tilted lens induced astigmatism, which reduced visual acuity to 20/250, in conjunction with a cataract. Cataract surgery was performed; the synechia between the lens capsule and the iris was severed, an intraocular lens was inserted, and the tilt was repaired. UBM was used postoperatively to confirm that the lens capsule synechia had been corrected and that the intraocular lens was not tilted. As a result, visual acuity improved to 20/100; glaucoma and expansion of corneal opacity were not observed. Conclusions: Severing of the synechia between the cataract and iris, during cataract surgery, in a patient with Peters' anomaly type 2 resulted in favorable postoperative visual acuity.

  17. Phakic anterior chamber intraocular lens (Verisyse™) implantation in children for treatment of severe ansiometropia myopia and amblyopia: Six-month pilot clincial trial and review of literature

    OpenAIRE

    Pirouzian, Amir; Ip, Kenneth C; O’Halloran, Henry S

    2009-01-01

    Purpose: The current study aims to evaluate both safety and efficacy of Verisyse™ (AMO, Irvine, CA) phakic anterior chamber intraocular lens (IOL) in the reduction of clinically significant (>−8 D) myopic anisometropia in children who are noncompliant to traditional medical treatment including spectacle correction or contact lenses. Design: Retrospective interventional case series. Methods: Six anisometropic myopic pediatric patients in one practice were identified through chart-review. None ...

  18. Phakic anterior chamber intraocular lens (Verisyse™) implantation in children for treatment of severe ansiometropia myopia and amblyopia: Six-month pilot clincial trial and review of literature

    Science.gov (United States)

    Pirouzian, Amir; Ip, Kenneth C; O’Halloran, Henry S

    2009-01-01

    Purpose: The current study aims to evaluate both safety and efficacy of Verisyse™ (AMO, Irvine, CA) phakic anterior chamber intraocular lens (IOL) in the reduction of clinically significant (>−8 D) myopic anisometropia in children who are noncompliant to traditional medical treatment including spectacle correction or contact lenses. Design: Retrospective interventional case series. Methods: Six anisometropic myopic pediatric patients in one practice were identified through chart-review. None of the patients were compliant with specatacle correction or contact lens wear and as a result had dense amblyopia of less than 20/400 by Snellen or Allen visual acuity (mean 6 lines was achieved in four patients (mean visual acuity of 20/70 at six months). Improvement in stereoacuity was noted in all six patients (from total mean zero seconds-arc to six-months post-operative mean of 500 seconds-arc by randot stereoacuity testing). Improvement of >2 lines of visual acuity lines was achieved in the other two patients. No patient lost any lines of visual acuity. Enhanced physical activity, coordination, and improved social interaction were noted in patients and were reported by the parents. No intra/post-operative complications were noted. Discussion: Irreversible or intractable amblyopia secondary to severe anisometropic myopia is a serious medical concern in the pediatric population. Failure of compliance with contact lens therapy consistently leads to visual loss. Anterior chamber phakic IOLs may provide a safe alternative in treatment of noncompliant anisometropic myopic patients who do not accept spectacle wear or contact lens therapy. Conclusion: To reduce or eliminate highly significant anisometropic myopia in children who are noncompliant with traditional medical treatment, phakic anterior chamber IOL implantation may be considered as an alternative modality of treatment. PMID:19668592

  19. 玻璃体切除治疗增生性糖尿病视网膜病变保留晶状体前囊膜的临床观察%Clinical investigation on anterior capsule preservation in surgical management for severe proliferative diabetic retinopathy

    Institute of Scientific and Technical Information of China (English)

    张远霞; 姚毅; 黄厚斌; 王志军

    2010-01-01

    Objective To report the outcomes of patients treated with the anterior capsule preservation technique used in surgical management for severe proliferative diabetic retinopathy.Methods Anterior capsule was preserved following pars plana lensectomy or fragmentation during vitrectomy for cataract patients with proliferative diabetic retinopathy,all eyes presented tractional and tractional/rhegmatogenous retinal detachment and involvement of posterior retina.Postoperatively,the transparency of anterior capsule was classified into A,B,C and D degrees according to the photographic record.The outcomes of visual acuity,retinal reattachment,intraocular pressure and the complications related to the operation as well as their managements were analyzed.Results Vitrectomy,silicone oil tamponade and anterior capsule preservation were performed in 58 eyes.The transparency of the anterior capsule in these eyes was degree A in 26 eyes(44.8%) ;degree B in 20 eyes(34.5%) ;degree C in 7 eyes (12.1%) and degree D in 5 eyes (8.6%).Forty eyes (79.3%) had a postoperative best corrected visual acuity ≥0.05,21 eyes received secondary intraocular lens implantation.Finally,7 eyes were classified to be silicone oildepended eyes because of severe proliferative changes occurred and the presence of macular hole.Complications related to the operation included iris mal-cut in 1 eye,siiicone oil escaped into anterior chamber in 7 eyes,iris neovascularization and new vascular glaucoma in 1 eye respectively,intraocular pressure elevation in 4 eyes,secondary pre-macular membrane formation in 11 eyes and macular hole in 2 eyes.Conclusions The anterior capsule preservation procedure and selective secondary intraocular lens implantation is an acceptable method in surgical management for severe proliferative diabetic retinopathy.The main causes of the opacification of anterior capsule are the proliferation of residual lens epithelial cells and blood deposit on the posterior surface.Silicone oil escaped

  20. Phakic anterior chamber intraocular lens (Verisyse™ implantation in children for treatment of severe ansiometropia myopia and amblyopia: Six-month pilot clincial trial and review of literature

    Directory of Open Access Journals (Sweden)

    Amir Pirouzian

    2009-06-01

    Full Text Available Amir Pirouzian1,3, Kenneth C Ip2, Henry S O’Halloran31The Permanente Medical Group, Santa Clara, CA, USA; 2The Permanente Medical Group, San Francisco, CA, USA; 3Rady’s Children’s Hospital of San Diego, San Diego, CA, USAPurpose: The current study aims to evaluate both safety and efficacy of Verisyse™ (AMO, Irvine, CA phakic anterior chamber intraocular lens (IOL in the reduction of clinically significant (>-8 D myopic anisometropia in children who are noncompliant to traditional medical treatment including spectacle correction or contact lenses.Design: Retrospective interventional case series.Methods: Six anisometropic myopic pediatric patients in one practice were identified through chart-review. None of the patients were compliant with specatacle correction or contact lens wear and as a result had dense amblyopia of less than 20/400 by Snellen or Allen visual acuity (mean <20/400. All patients underwent Verisyse™ phakic IOL implantation in the more myopic eye by one surgeon (AP. Pre- and post-operative visual acuity, anterior/posterior segment examination, stereoacuity, axial biometry measurements, cycloplegic refraction, and endothelial cell counts were performed in all patients whenever feasible.Results: The age of patients ranged from 5–11 years. The mean post-operative follow-up time was six months from the time of IOL insertion. Improvement in visual acuity >6 lines was achieved in four patients (mean visual acuity of 20/70 at six months. Improvement in stereoacuity was noted in all six patients (from total mean zero seconds-arc to six-months post-operative mean of 500 seconds-arc by randot stereoacuity testing. Improvement of >2 lines of visual acuity lines was achieved in the other two patients. No patient lost any lines of visual acuity. Enhanced physical activity, coordination, and improved social interaction were noted in patients and were reported by the parents. No intra/post-operative complications were noted

  1. Pupil-occluding organized hyphema anterior to the intraocular lens treated by neodymium: yttrium-aluminum-garnet laser: a case report

    Science.gov (United States)

    Kim, Moosang; Lee, Seung-Jun; Han, Sang Beom; Yang, Hee Kyung; Hyon, Joon Young

    2016-01-01

    We report, to our best knowledge, the first case of treatment of pupil-occluding postoperative organized hyphema anterior to the intraocular lens (IOL) using neodymium: yttrium-aluminum-garnet (Nd:YAG) laser. A 78-year-old Asian female underwent uneventful cataract operation. She had been taking aspirin, which she discontinued 1 week before surgery. Iris prolapse occurred at the end of the surgery, which led to intracameral bleeding. Two weeks later, her best-corrected visual acuity was hand motion. Although hyphema had decreased, pupil-occluding organized hematoma had formed anterior to the IOL. The blood clot anterior to the IOL was removed using Nd:YAG laser. One week later, although the hematoma anterior to the IOL resolved, endocapsular hematoma was observed, which was dispersed with Nd:YAG laser posterior capsulotomy. Two weeks later, her best-corrected visual acuity improved to 20/60. There was no complication associated with Nd:YAG laser. In conclusion, pupil-occluding organized hyphema anterior to the IOL can occur as a complication of cataract surgery, in which Nd:YAG laser can be a useful treatment option. PMID:27462181

  2. Incidence of posterior capsule opacification following the implantation of a foldable hydrophilic acrylic intraocular lens: a 4 year follow-up study

    Directory of Open Access Journals (Sweden)

    Priscilla de Almeida Jorge

    2014-08-01

    Full Text Available Purpose: To evaluate the incidence of posterior capsule opacification (PCO four years after the implantation of a hydrophilic acrylic intraocular lens (IOL. Methods: Fifty-eight randomly selected eyes from 58 patients were analyzed four years after phacoemulsification and Ioflex IOL implantation. The patients underwent an ophthalmic examination to detect PCO and a detailed medical history was obtained. The patients' charts were reviewed for their corrected distance visual acuity prior to the IOL implantation, as well as for one month postoperatively. The Student's t-test was used for statistical analysis. Results: The mean age of patients without PCO was 74.6 ± 9.5 years, compared to 70.3 ± 15 years in patients with PCO. Four years after surgery, 39 of the 58 eyes (67% had detectable PCO and 24 eyes (41.3% had decreased visual acuity (VA due to PCO. These patients were referred for Nd:YAG laser capsulotomy. Three patients (5.1% had decreased VA due to glaucoma, IOL opacification, or age-related macular degeneration. Twelve eyes (20.7% presented mild PCO with unchanged VA. Systemic arterial hypertension was reported by 45% of the patients, and in 3.5% of these cases this was associated with diabetes mellitus. Conclusion: This study found the incidence of PCO to be 67% four years after phacoemulsification and Ioflex IOL implantation.

  3. Capsule contraction syndrome

    Directory of Open Access Journals (Sweden)

    Mesut COŞKUN

    2009-06-01

    Full Text Available Capsule contraction syndrome occurs after fibrous metaplasia of lens proteins that leads to capsular bag contraction. Excessive front capsular wrinkling is seen in capsule contraction syndrome and there is an imbalance between powers supplying capsular integrity. This situation leads to zonular weakness. Capsule contraction syndrome is associated with pseudoexfoliation, older age, uveitis, pars planitis and myotonic muscular dystrophy. In order to decrease the risk of capsule contraction syndrome, front capsulerhexis area should be open as 5.5-6 mm diameter and a curysoft intraocular lens should be used. In order to prevent lens epithelial proliferation and metaplasia, lens epithelial cells at inferior surface of front capsule should be aspirated carefully. If postoperative capsular contraction detected, front capsulotomy should be performed by Nd-YAG laser at postoperative 2 to 3 weeks. In patients that Nd-YAG laser is unsuccessful, capsular tension should be decreased by surgical microincisions. In present study, we evaluated etiology, prevention and management of capsule contraction syndrome in the light of actual literature knowledge.

  4. Biometric, optical and physical changes in the isolated human crystalline lens with age in relation to presbyopia.

    Science.gov (United States)

    Glasser, A; Campbell, M C

    1999-06-01

    The biometric, optical and physical properties of 19 pairs of isolated human eye-bank lenses ranging in age from 5 to 96 years were compared. Lens focal length and spherical aberration were measured using a scanning laser apparatus, lens thickness and the lens surface curvatures were measured by digitizing the lens profiles and equivalent refractive indices were calculated for each lens using this data. The second lens from each donor was used to measure resistance to physical deformation by providing a compressive force to the lens. The lens capsule was then removed from each lens and each measurement was repeated to ascertain what role the capsule plays in determining these optical and physical characteristics. Age dependent changes in lens focal length, lens surface curvatures and lens resistance to physical deformation are described. Isolated lens focal length was found to be significantly linearly correlated with both the anterior and posterior surface curvatures. No age dependent change in equivalent refractive index of the isolated lens was found. Although decapsulating human lenses causes similar changes in focal length to that which we have shown to occur when human lenses are mechanically stretched into an unaccommodated state, the effects are due to nonsystematic changes in lens curvatures. These studies reinforce the conclusion that lens hardening must be considered as an important factor in the development of presbyopia, that age changes in the human lens are not limited to the loss of accommodation that characterizes presbyopia but that the lens optical and physical properties change substantially with age in a complex manner.

  5. Evaluation of Changes in Anterior Segment Configuration by Ultrasound Biomicroscopy after Phacoemulsification and Foldable Intraocular Lens Implantation

    Directory of Open Access Journals (Sweden)

    ilhami Salcan

    2011-08-01

    Full Text Available Purpose: To quantify the configuration changes in anterior segment structures after cataract extraction using ultrasound biomicroscopy (UBM. Material and Method: 33 eyes of 33 patients (21 male, 12 female; mean age: 69.0±8.3 years with senile or presenile cataracts undergoing cataract surgery were prospectively studied. UBM was performed for each patient before and 1 month after surgery. At each UBM examination, axial images of the anterior chamber and radial sections of the angle in four quadrants were obtained. The measurements were performed by using the calipers included in the equipment software and UBM Pro2000® software. Results: After cataract surgery, we determined statistically significant increases in anterior chamber depth and angle parameters (p=0.001. We found that the postoperative increases in anterior chamber depth, angle recess area, angle opening distance 250 and angle opening distance 500 were 1.3, 1.4, 1.7 and 1.5 times, respectively, when compared with the preoperative levels. Decreases in acceleration and increases in y-intercept were determined in 4 quadrants postoperatively by of linear regression analysis of anterior chamber angle and these were also statistically significant (p=0.001. Discussion: UBM gives both qualitative and quantitative valuable information about anterior segment structures. We think that UBM may be a useful tool for evaluation of patients with cataract and occludable and/or narrow angles undergoing cataract surgery for therapeutic purpose. (Turk J Ophthalmol 2011; 41: 200-6

  6. Clinical application of the three-piece intraocular lens with optical surfaces entrapment by the posterior capsule in secondary intraocular lens implantation of the pediatric cataract for preventing lens dislocation%三片式人工晶状体光学面后囊孔嵌压术在预防儿童白内障二期人工晶状体脱位应用

    Institute of Scientific and Technical Information of China (English)

    王志亮

    2014-01-01

    目的 评价三片式人工晶状体光学面后囊孔嵌压术在预防儿童白内障二期人工晶状体脱位的临床疗效.方法 选择2009年10月至2010年11月期间在邢台市眼科医院就诊的5岁以内儿童无晶状体眼患儿76例152只眼.手术分为两组,A组(单纯人工晶状体睫状沟植入组)80只眼;B组(人工晶状体光学面后囊孔嵌压组)72只眼,随访3~19个月,平均11个月.结果 A组80只眼中有13只眼出现人工晶状体脱位,B组72只眼中只有1只眼出现人工晶状体瞳孔夹持,两组对比有统计学意义(x2=10.01,P<0.05).结论 使用光学部直径大的三片式人工晶状体,将其光学部确实地嵌压在后囊孔后,可以有效地预防儿童白内障二期人工晶状体植入术后人工晶状体脱位.%Objective To assess the clinical effects of the three-piece intraocular lens which optical surfaces were captured by the posterior capsule in secondary intraocular lens implantation of the pediatric cataract.Methods The 152 eyes of children less than 5 years old with aphakia were selected between October 2009 and November 2010.Operation was divided into two groups,Group A (the intraocular lens which were implanted at ciliary sulcus) 80 eyes,Group B (the intraocular lens which optical surfaces were captured by the posterior capsule) 72 eyes,follow-up duration was from 3 to 19 months,an average of 11 months.Results In group A,there were 13 eyes of intraocular lens dislocation.In group B,there was only 1 eye of intraocular lens captured by the pupil.There was significant difference between two groups (P <0.05).Conclusions The three-piece intraocular lens which big optical surfaces are captured by the posterior capsule can prevent the dislocation in secondary intraocular lens implantation of the pediatric cataract.

  7. Foldable Lens Explantation and Exchange:The Reason and Solution

    Institute of Scientific and Technical Information of China (English)

    Danying Zheng; Zhenpin Zhang; Wenhui Yang; Weirong Chen

    2001-01-01

    Objective: To report the explantation and exchange of Hydrophilic Acrylic foldable intraocular lens (IOL) on 14 patients who had visual disturbances caused by the change of transparence on optic. Methods: Sixteen Hydrophilic Acrylic foldable intraocular lenses from 14 patients who presented with decreased visual acuity from 6 months to 1 year after normal phacoemulsification and IOL implantation associated with extensive transparent change on optic of the lens. The lenses were explanted with the bisection technique. All the eyes were reinserted with Acrysof foldable lenses. Results: Sixteen lenses were removed successfully and exchanged with the new lens in the capsule. The posterior capsular rupture and vitreous loss were found in the first two cases. One of them had the zonulysis due to the radial tear of the anterior capsule during the enlargement of the capsular opening. The anterior vitrectomy was performed with IOL fixed on the ciliary sulcus. The visual acuity of all the patients improved obviously without posterior complication. Conclusion: Foldable lens explantation with the bisection technique and exchange had a successful outcome with improvement of ocular condition. Eye science 2001; 17:54 ~56.

  8. Out-of-the-bag intraocular lens dislocation: outcomes of posterior chamber intraocular lens exchange, risk factors, and prevention

    Institute of Scientific and Technical Information of China (English)

    ZHENG Dan-ying; CHEN Li-na; SUN Yi; SHAO Ying-feng; LIANG Jing-li; LIU Yi-zhi

    2010-01-01

    Background Dislocation of posterior chamber intraocular lens is one of the most common complications of intraocular lens implantation. Lens exchange is an effective solution to this unsatisfactory status. This study was conducted to analyze the possible predisposing factors for out-of-the-bag posterior chamber intraocular lens dislocation and to study the outcomes of lens exchange surgery.Methods Thirty-six consecutive patients (36 eyes) with out-of-the-bag intraocular lens dislocation who underwent posterior chamber intraocular lens exchange in Zhongshan Ophthalmic Center of Sun Yat-sen University (Guangdong,China) from January 2003 to October 2009 were included. A 6-month follow-up was completed. The causes for out-of-the-bag intraocular lens dislocation and visual outcomes of posterior chamber intraocular lens exchange were analyzed. The out-of-the-bag intraocular lens dislocation was diagnosed on the basis of the findings from slit-lamp microscope and B-ultrasound. The dislocated intraocular lens was explanted. Reimplantation of a new posterior chamber intraocular lens was performed in each case using standardized surgical procedures.Results In this study, a total of thirty-six consecutive patients (36 eyes) with out-of-the-bag intraocular lens dislocation underwent posterior chamber intraocular lens exchange surgery. Causes for out-of-the-bag intraocular lens dislocation included posterior capsule rupture during the initial cataract extraction procedure (23 eyes, 63.8%), trauma (5 eyes,13.9%), neodymium-doped yttrium aluminium garnet (Nd:YAG) laser-induced dislocation (2 eyes, 5.6%), the status after vitrectomy (2 eyes, 5.6%) and unidentifiable etiology (4 eyes, 11.1%). Symptoms of these patients mainly included decrease in visual acuity (17 cases, 47.2%), blurred vision (16 cases, 44.4%), glare (1 case, 2.8%), diplopia (1 case,2.8%), and halo (1 case, 2.8%). Intraocular lens dislocation into the posterior vitreous cavity (29 eyes, 80.5%), anterior chamber (1

  9. Lens siderosis resulting from a small intralenticular metallic foreign body

    Directory of Open Access Journals (Sweden)

    Shah, Mehul A.

    2015-11-01

    Full Text Available We report a rare case of lens siderosis with an undetectable intraocular foreign body by imaging. An 8-year-old boy presented with diminution of vision in the left eye since 3 months. His parents gave a preceding uncertain history of a foreign body injury to his left eye 3 months ago while playing. Presenting visual acuity in the left eye was perception of hand movements. Slit-lamp examination revealed a total white cataract with brownish-pigmented spots on the anterior capsule of the lens, but no intraocular foreign body was found. There was also no evidence of an intraocular foreign body on ultrasonography. Patient underwent cataract extraction with intraocular lens implantation. During the operation, a small (2×1×1 mm in size intralenticular foreign body of metal material was found and removed carefully with a magnet. The patient regained 20/30 vision after surgery.

  10. Inflammatory Response in the Anterior Chamber after Implantation of an Angle-Supported Lens in Phakic Myopic Eyes

    Directory of Open Access Journals (Sweden)

    Suphi Taneri

    2014-01-01

    Full Text Available Purpose. To evaluate the inflammatory reaction after implantation of an angle-supported foldable acrylic anterior chamber IOL for myopia correction over time. Methods. Adult individuals seeking vision correction with stable myopia >7.0 D were included. Exclusion criteria are anterior chamber depth <2.8 mm, insufficient endothelial cell density, other preexisting ocular conditions, and prior eye surgery. Laser flare photometry and slitlamp examination were performed before and up to 1 year after implantation of an AcrySof Cachet IOL (Alcon Laboratories, Forth Worth, TX, USA. Postoperative treatment comprised antibiotic eye-drops for 5 days and nonsteroidal anti-inflammatory eye-drops (NSAIDs for 4 weeks. Results. Average laser flare values of 15 consecutive eyes of 15 patients were 8.3±9.7 preoperatively and 19.0±24.2 (1 day, 24.0±27.5 (1 week, 17.6±13.4 (1 month, 14.9±15.4 (3 months, and 10.0±7.0 (1 year photon counts/ms after implantation, respectively. Slitlamp examination yielded 0 or 1+ cells (SUN classification in every one eye throughout the follow-up period. Conclusion. Results indicate a low maximum inflammatory response and a quick recovery to a long-term safe level. The use of NSAIDs seems sufficient in routine cases, thus avoiding potential drawbacks of using corticoids.

  11. Iatrogenic Lens Injuries

    Directory of Open Access Journals (Sweden)

    Ümit Kamış

    2012-12-01

    Full Text Available During intraocular surgery, undesired damages of various etiology may occur in adjacent tissues. One of these tissues is the crystalline lens, which may be traumatized both in anterior segment and posterior segment surgeries, and when damaged, it usually causes marked decrease in visual acuity. The leading causes of iatrogenic lens injuries are intravitreal injection, laser iridotomy, phakic intraocular lens implantation, anterior chamber paracentesis, and vitreoretinal surgery. When crystalline lens damage occurs, its negative effect on visual function may be eliminated by performing cataract surgery intraoperatively or in elective conditions. (Turk J Ophthalmol 2012; 42: Supplement 27-30

  12. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-01-01

    Abstract The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement. This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China. Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I—capsule with mild opacification but no invasion into the capsule opening; Type II—capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III—capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed. The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I—120 eyes (38.1%); Type II—157 eyes (49.8%); Type III—38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = −0.572, P < 0.001), but no significant correlation with intraoperative posterior capsulorhexis size (R = −0.16, P = 0.122) was observed. The ACOA significantly decreased from Type I to Type II to Type III, the PCOA increased in size from Type I to Type

  13. Results of cataract surgery and plasma ablation posterior capsulotomy in anterior persistent hyperplastic primary vitreous

    Directory of Open Access Journals (Sweden)

    Rajesh Sinha

    2013-01-01

    Full Text Available Purpose: To report the feasibility and outcome of lens aspiration, and Fugo blade-assisted capsulotomy and anterior vitrectomy in eyes with anterior persistent hyperplastic primary vitreous (PHPV. Materials and Methods: In this case series, 10 eyes of 10 patients with anterior PHPV underwent lens aspiration. The vascularized posterior capsule was cut with a Fugo blade (plasma knife and removed with a vitrector. A foldable posterior chamber intraocular lens (IOL was implanted in eight eyes and the outcomes were evaluated. Results: The mean age of patients was 16.8 ± 6.37 months (range: 5 to 28 months. The surgery was completed successfully in all eyes. There were no cases of intraocular hemorrhage intraoperatively. Foldable acrylic IOL was implanted in the bag in 3 eyes and in the sulcus in 5 eyes. Two eyes were microphthalmic and did no undergo IOL implantation (aphakic. None of the eyes had a significant reaction or elevated intraocular pressure postoperatively. The follow-up ranged from 4 to 21 months. All the pseudophakic eyes achieved a best corrected visual acuity of ≥20/200 with 50% (4/8 of these eyes with ≥20/60 vision. Conclusion: Lens aspiration followed by posterior capsulotomy with Fugo blade-assisted plasma ablation is a feasible technique for performing successful lens surgery in cases with florid anterior PHPV.

  14. Immunohistochemical observation of anterior subcapsular cataract in eye with spontaneously regressed retinoblastoma.

    Science.gov (United States)

    Shirai, Kumi; Okada, Yuka; Saika, Shizuya

    2010-03-01

    We report the histological findings of secondary cataract in an eye with a spontaneously regressed retinoblastoma to obtain keys to clarify the mechanism of this phenomenon. During phacoemulsification, opacified anterior capsule was obtained, fixed in formalin, and embedded in paraffin. Paraffin sections of the specimen were histologically observed. Hematoxylin-eosin staining showed extracellular matrix accumulation in the extracted fibrous anterior subcapsular opacification. Immunohistochemistry revealed the presence of fibrous collagen types and cellular fibronectin. Presumed lens cells amid matrix were positively labeled for vimentin, alpha-smooth muscle actin, and phospho-Smad2. Histology of the fibrous anterior subcapsular opacification tissue showed the possibility of epithelial-mesenchymal transition of the lens epithelial cells in the secondary cataract following a spontaneously regressed retinoblastoma.

  15. The Experimental Study on Implantation of Intraocular Lens in Different Animals

    Institute of Scientific and Technical Information of China (English)

    WANGGui-qin; PENGXiu-jun; GUHan-qing

    2004-01-01

    To prevent the complications in cataract surgeries, the eyes of rabbits and monkeys were implanted with intraocular lens for 360 days. Methods: The eyes of the rabbits were performed with phacoemulsification and soft intraocular lens implantation. The eyes of the monkeys were performed with extracapsular cataract extraction and hard intraocular lens implantation. Results: The postoperative reactions included corneal edema, anterior chamber exudation, posterior capsule opacification and so on. The complications in the eyes of the rabbits were more than that in the eyes of the monkeys. Conclusion: The different postoperative reactions happened in different animals. In clinical the choice of the operative method and intraocular lens depended on the case in order to acquire the best sight.

  16. Phakic anterior chamber intraocular lens (Verisyse™) implantation in children for treatment of severe ansiometropia myopia and amblyopia: Six-month pilot clincial trial and review of literature

    OpenAIRE

    Pirouzian, Amir

    2009-01-01

    Amir Pirouzian1,3, Kenneth C Ip2, Henry S O’Halloran31The Permanente Medical Group, Santa Clara, CA, USA; 2The Permanente Medical Group, San Francisco, CA, USA; 3Rady’s Children’s Hospital of San Diego, San Diego, CA, USAPurpose: The current study aims to evaluate both safety and efficacy of Verisyse™ (AMO, Irvine, CA) phakic anterior chamber intraocular lens (IOL) in the reduction of clinically significant (>-8 D) myopic anisometropia in childre...

  17. Repositioning a decentered intraocular lens with 4 haptics.

    Science.gov (United States)

    Liu, Jiewei; Liu, Wenjie; Jia, Yading; Al-Mohtaseb, Zaina N; Wang, Li

    2016-03-01

    We describe a technique to reposition a decentered 4-haptic intraocular lens (IOL). Using an ophthalmic viscosurgical device, the haptic with the worst distortion is dissected from the capsular bag and pulled outside the bag. The opposite haptic (180 degrees away) is also dissected and placed in front of the anterior capsule. The remaining 2 haptics are left in the capsular bag. With this repositioning, the 2 haptics in the bag limit the IOL movement, the 2 haptics outside the bag are no longer distorted, and the IOL is centered. We present 2 cases in which this technique was used to reposition decentered 4-haptic IOLs.

  18. Capsule endoscopy

    DEFF Research Database (Denmark)

    Skovsen, Anders Peter; Burcharth, Jakob; Burgdorf, Stefan Kobbelgaard

    2013-01-01

    of capsule retention, especially in patients with known or suspected Crohn's disease, due to the propensity of Crohn's disease to form stenosis of the bowel. In cases where a stenosis is suspected, it is warranted to perform a patency capsule swallow before subjecting the patient to a capsule endoscopy....

  19. Lens Epithelial Cell Proliferation and Cell Density in Human Age-related Cataract

    Institute of Scientific and Technical Information of China (English)

    Xialin Liu; Yizhi Liu; Jianliang Zheng; Qiang Huang; Huling Zheng

    2000-01-01

    Purpose: To discuss the potential effect of the lens epithelial cell proliferation in age-related cataract.Methods: In vitro cell proliferation was assayed by MTT method to evaluate the lens epithelial cell density, index, and proliferation capacity in normal lens and all kinds of age-related cataract. Capsulotomy specimens from all kinds of patients who underwent cataract phacoemulsification extraction surgery were compared with the lens epithelial specimens from non-cataract lenses of Eye Bank eyes.Results: Lens epithelial cell density of central anterior capsule (LECD) in female normal lens was higher than that in male, LECD in nuclear cataract( > NⅢ ) was higher than that in normal lens, but in the mature cortical cataract, LF CD was lower. Mitotic index of three kinds of age-related cataracts in vivo had no statistical difference, neither did cell proliferation capacity of cultivated cells in vitro.Conclusion: The individual difference of lens epithelial cell density and proliferation capacity in vivo may be an important underlying cause for senile cataract in the cellular level, especially for nuclear cataract.

  20. 超声生物显微镜观察弹性开放襻前房型人工晶状体对眼前段结构的影响%The influence of flexible open-loop anterior chamber intraocular lens on the structure of ocular anterior segment

    Institute of Scientific and Technical Information of China (English)

    陈伟蓉; 刘奕志; 陈秀琦; 程冰; 刘玉华

    2001-01-01

    Objective To evaluate the therapeutic effects and safety offlexible open-loop anterior chamber intraocular lens (FOAC-IOL). Methods By ultrasound biomicroscopy, the positions of the haptics of FOAC-IOL in 20 patients (20 eyes) and the relationships of the haptics with iris and anterior chamber angle structures were observed postoperatively to evaluate the impact of these lenses on the structures of ocular anterior segment. Follow-up duration was from 6 to 20 months. Results Among 40 IOL′s haptics, twenty-six haptics were fixed at the recess of the chamber angle ;and other fourteen haptics penetrated the iris and invaded into the ciliary stroma, which caused recurrent uveitis. There was 1 eye with eccentric lens. There were 8 eyes with anterior synechiae of iris, which were related to the haptics of intraocular lens. Conclusions Ultrasound biomicroscopy works well in dynamic observation of the influence of intraocular lens on ocular anterior segment. The haptics of flexible open-loop anterior chamber intraocular lens should be modified.%目的 评价弹性开放襻一体型前房型人工晶状体(anterchamberintraocularlens,AC-IOL)植入术的疗效及其安全性。方法 应用超声生物显微镜观察20例(20只眼)弹性开放襻一体型AC-IOL植入术后患者IOL襻的位置,以及其与虹膜及房角结构的关系,从而评价IOL对眼前段结构的影响。随访时间6~20个月。结果 40个IOL襻中,26个襻固定于房角隐窝;14个襻(8只眼)穿过虹膜侵入至睫状体实质内,并伴有反复发作的葡萄膜炎。术后8只眼虹膜前粘连与IOL襻有关。结论超声生物显微镜检查是动态了解IOL对眼前段结构影响的有效方法。AC-IOL襻的设计有待进一步改进。

  1. 角膜塑形镜对角膜前后表面曲率半径和前房深度的影响%The affect of orthokeratology lens to the anterior and posterior corneal surface and anterior chamber depth

    Institute of Scientific and Technical Information of China (English)

    陈蛟; 肖满意; 王华; 郭颖卓; 何书喜

    2013-01-01

      目的:探讨角膜塑形镜对角膜前后表面曲率半径和前房深度的影响。方法:用Orbscan-Ⅱ角膜地形图,检查17例31眼配戴角膜塑形镜3个月后角膜前后表面曲率半径和前房深度的变化。结果:配戴角膜塑形镜3个月后所有患者屈光度下降,裸眼视力上升(P0.05)。结论:角膜塑形镜主要通过改变角膜前表面的曲率,压平角膜前表面达到矫正近视的目的,对角膜后表面与前房深度无明显影响。%Objective To find out the affect of orthokeratology lens to the anterior and posterior corneal sur-face and anterior chamber depth.Methods 17 patients ,31eyes, after 3 months orthokeratology wearing, corneal topography examination with Orbscan-Ⅱ,record the changes of the anterior and posterior corneal surface radius and anterior chamber depth.Results After 3 months orthokeratology wearing, the refraction diopter decline, uncor-rected visual acuity increased (P0.05).Conclusion Orthokeratology lens mainly affects the shape of the anterior corneal surface , flatten the anteri-or corneal surface, rather than change of the posterior corneal surface radius and anterior chamber depth to achieve the effect of reducing refraction.

  2. Contaminação bacteriana da câmara anterior pós-facoemulsificação com implante de lente intra-ocular de polimetilmetacrilato ou silicone Bacterial anterior chamber contamination after phacoemulsification and polymethylmethacrylate or silicone intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Ricardo Antonio Pereira

    2004-12-01

    Full Text Available OBJETIVO: Avaliar a contaminação bacteriana da câmara anterior, após facoemulsificação não complicada, com tamanhos diferentes de incisões e lentes intra-oculares. MÉTODOS: Foi realizado estudo prospectivo randomizado, de 80 olhos de 80 pacientes, submetidos à facoemulsificação sob anestesia tópica, distribuídos aleatoriamente em dois grupos iguais. No grupo A foram alocados os pacientes submetidos à cirurgia com incisão de 3,0 mm, lente intra-ocular dobrável de silicone implantadas com injetor. No grupo B os pacientes foram submetidos à cirurgia com incisão de 5,8 mm e implante de lente intra-ocular de polimetilmetacrilato de peça única, com pinça. Ao final de cada cirurgia, uma amostra do líquido da câmara anterior foi colhida e semeada em meios de cultura para bactérias. RESULTADOS: A cultura do líquido da câmara anterior foi positiva em 2,5% dos casos do grupo A e em 5,0% do grupo B. Não houve diferença estatisticamente significante entre os dois grupos (chi2 = 0, 380, p> 0,05. CONCLUSÃO: O implante de lente intra-ocular através de incisão menor, não resultou em menor contaminação da câmara anterior na cirurgia de facoemulsificação.PURPOSE: To evaluate bacterial anterior chamber contamination following uncomplicated phacoemulsification with differents sizes of incisions. METHODS: Prospective randomized study, 80 eyes, 80 patients divided into two groups, were submitted to phacoemulsification with topical anaesthesia. In group A, with 40 patients, surgery was perfomed with 3.0 mm incision and silicone intraocular lens implant with injector. In group B the surgery was done with 5.8 mm incision and polymethylmethacrylate intraocular lens implant with forceps. Anterior chamber aspirate was taken for culture upon completion of surgery in each case. RESULTS: Anterior chamber cultures were positive in 2.5% of the cases in group A, and 5.0% in group B (chi-square test = 0.380, p>0.05, frequencies of

  3. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... it to have any real negative or deleterious effect by removing the anterior capsule. Now I would ... is what happens with one of the competitive designs. Like I told you, I just take a ...

  4. Avaliação da contaminação da câmara anterior na cirurgia de facoemulsificação com implante de lente intra-ocular Anterior chamber contamination in phacoemulsification surgery with intraocular lens implant

    Directory of Open Access Journals (Sweden)

    Cesar Nobuo Shiratori

    2002-06-01

    Full Text Available Objetivo: Avaliar a existência de contaminação da câmara anterior durante a facectomia por facoemulsificação com implante de lente intra-ocular. Método: Foi realizado estudo prospectivo, avaliando-se 30 pacientes submetidos a facectomia por facoemulsificação com implante de lente intra-ocular, colhendo-se duas amostras de humor aquoso, uma obtida no início e outra no final da cirurgia. As amostras foram semeadas em meio de cultura para germes aeróbios, anaeróbios e fungos. Resultado: Todas as amostras avaliadas resultaram negativas. Conclusão: A contaminação da câmara anterior na cirurgia de facoemulsificação com implante de lente intra-ocular, usando os cuidados necessários, é infreqüente.Purpose: To evaluate the frequency of anterior chamber contamination during phacoemulsification surgery with intraocular lens implant. Method: A prospective study was done with 30 patients submitted to phacoemulsification surgery with intraocular lens implant. Two samples of the aqueous humor were removed from the anterior chamber, one at the beginning and another one at the end of the surgery and were inoculated in culture plates for anaerobic and aerobic bacteria and fungi. Results: Intraocular aspirates yielded negative cultures. Conclusion: The absence of microorganisms in the samples evaluated allowed us to conclude that contamination during the phacoemulsification surgery with lens implant is unusual.

  5. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation: Qualitative Classification and Quantitative Measurement.

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-03-01

    The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement.This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China.Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I-capsule with mild opacification but no invasion into the capsule opening; Type II-capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III-capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed.The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I-120 eyes (38.1%); Type II-157 eyes (49.8%); Type III-38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = -0.572, P < 0.001), but no significant correlation with intraoperative posterior capsulorhexis size (R = -0.16, P = 0.122) was observed. The ACOA significantly decreased from Type I to Type II to Type III, the PCOA increased in size from Type I to Type II, and the PCOO increased

  6. Evaluation of immersion 20 MHz B-scan ultrasonography in observing lens in the alkali burn eyes

    Institute of Scientific and Technical Information of China (English)

    Qing-Hua; Yang; Bing; Chen; Li-Qiang; Wang; Guang-Hua; Peng; Zhao-Hui; Li; Yi-Fei; Huang

    2014-01-01

    ·AIM: To evaluate the accuracy of 20 MHz immersion Bscan ultrasonography in observing lens and to investigate the value of this noninvasive preoperative diagnosis method in alkali burn eyes.·METHODS: It was a comparative study. Fifty-six cases(56 eyes) of alkali burn eyes were examined by ultrasound biomicroscopy(UBM) and immersion 20 MHz B-scan ultrasonography from June 2011 to April 2013,the images were analyzed, and the ultrasonographic diagnosis compared with the operation results.·RESULTS: In 56 alkali burn eyes examined by UBM, the lens were not detected in 16 eyes; the IOL could be detected in 2 eyes; the anterior lens capsule surface or/and the front lens could be detected in 18 eyes, and lens opacification in 3 eyes of them; suspected abnormal lens were detected in the other 20 eyes. In all the same eyes examined by immersion 20 MHz B-scan ultrasonography,the lens were not detected in 16 eyes; the IOL could be detected in 2 eyes; 24 abnormal lens(opacity, lens expansion, shrinkage) and 14 normal lens were found.Compared with the intraoperative findings, the diagnostic accordance rate of the immersion 20 MHz B-scan appearance of lens was 100%(56/56), which was significantly higher than examined by UBM 57.14%(32/56)(χ2=30.55, P =0.0000).·CONCLUSION: Immersion 20 MHz B-scan ultrasonography can observe the lens accurately in alkali burn eyes. It has important clinical value to combine with UBM in eyes of alkali burn.

  7. 类风湿关节炎患者人工晶状体植入后前房反应%Anterior chamber inflammation after intraocular lens implantation in patients with rheumatoid arthritis

    Institute of Scientific and Technical Information of China (English)

    马伟华; 赵俊丽

    2013-01-01

    目的 观察类风湿关节炎患者白内障囊外摘出人工晶状体植入术(ECCE+ IOL)与超声乳化吸出人工晶状体植入术(Phaco+ IOL),比较其术后前房反应程度;探讨类风湿因子滴度与术后前房反应的关系.方法 类风湿关节炎患者11例(11眼)行ECCE+ IOL术;10例(12眼)行Phaco+ IOL术.术后复诊随访.结果 除1例(1眼)视神经萎缩,1例(1眼)老年黄斑变性外,其它均获得了0.6或以上的矫正视力,3个月后前房炎症消失,无手术并发症;行Phaco+ IOL术后前房反应较ECCE +IOL术后前房反应轻,术后3d两组间的差异具有统计学意义(mann-whitney u test分析P=0.0258).术后3d、1个月不同前房反应组的类风湿因子之间差异无统计学意义(mann-whitney utest分析,P>0.05).结论 类风湿性关节炎患者Phaco+ IOL术后前房反应较ECCE +IOL术后前房反应轻;术后前房反应的程度与术前类风湿因子滴度无关.%Objective To compare the postoperative anterior chamber inflammation between extracapsular cataract extraction with intraocular lens implantation (ECCE + IOL) and phacoemulsification with intraocular lens implantation (Phaco + IOL) on patients with rheumatoid arthritis,and to investigate the relation of rheumatoid factor and inflammation in anterior chamber.Methods The medical records of 23 eyes of 21patients with rheumatoid arthritis were reviewed,who underwent cataract extraction with intraocular lens implantation.ECCE + IOL was performed in 11 cases (11 eyes),and Phaco + IOL was performed in 10 cases (12 eyes).Patients had been followed up for 3 months.Results All the eyes,except for one case of optic atrophy and one case of age-related macular degeneration,acquired visual acuity of 0.6 or better.Inflammation in anterior chamber disappeared 3 months after surgery,and left no operative complication in any of the eyes.The inflammation in anterior chamber on patients who performed Phaco + IOL was lighter than patients who performed

  8. 前房麻醉下囊膜上倾斜碎核法在高度近视硬核白内障术中应用%The method of nucleus breakage on anterior capsule to treat high myopia cataract under atrium anesthesia

    Institute of Scientific and Technical Information of China (English)

    王志; 李马号; 许建涛

    2015-01-01

    目的 探讨前房麻醉下囊膜上倾斜碎核法在高度近视硬核白内障手术的安全性和有效性.方法 对2010年2月至2014年3月在万州阳光眼科医院采用0.4%奥布卡因表麻后,再用1%的利多卡因前房麻醉下“囊膜上倾斜碎核法”,对82例(86只眼)眼轴≥28.5 mm,核为Ⅳ级以上的高度近视硬核白内障患者,行白内障超声乳化吸除联合人工晶状体植入术.用钛针对核中周部刻一浅槽,用高负压吸住一端的核的赤道部脱离至前囊上呈倾斜状,然后劈核钩插入核中周边的底部对撞分裂将核倾斜劈开一个小范围的核块,如此反复,将其乳化吸除.结果 术中无一例发生悬韧带断离,超声乳化过程中有3例后囊膜破裂(3.65%),经过前部玻璃体切割后植入后房型人工晶状体.术后52只眼(64.46%)裸眼视力≥0.3,72只眼(83.72%)矫正视力≥0.5,有3只眼因高度近视黄斑变性,术后视力未提高.术后角膜水肿,多在术后3~5 d消失.无一例发生大泡性角膜病和视网膜脱离.结论 前房麻醉下囊膜上倾斜碎核法对高度近视Ⅳ级以上硬核白内障行超声乳化联合人T晶状体植入术,能防止术中瞳孔缩小,且有散大瞳孔的作用.囊膜上倾斜碎核技术减轻了劈核时对囊袋及悬韧带的压力,避免了悬韧带断离、后囊破裂和晶状体脱位的发生,对眼内组织损伤小,操作简单易掌握,是白内障硬核处理技术的一种实用方法.%Objective To investigate the safety and efficiency of nucleus breakage on anterior capsule for high myopia cataract treatment.Methods From February 2010 to March 2014,82 high myopia patients (86 eyes,optic axis ≥28.5 mm) with at least IV degree hard nucleus cataract were operated with above mentioned method to erase nucleus,after 0.4% Oxybuprocaine topical anesthesia,then 1% Lidocaine used to perform intracameral anesthesia combined with transplant of artificial lens.At high negative pressure

  9. The lens equator: a platform for molecular machinery that regulates the switch from cell proliferation to differentiation in the vertebrate lens.

    Science.gov (United States)

    Mochizuki, Toshiaki; Masai, Ichiro

    2014-06-01

    The vertebrate lens is a transparent, spheroidal tissue, located in the anterior region of the eye that focuses visual images on the retina. During development, surface ectoderm associated with the neural retina invaginates to form the lens vesicle. Cells in the posterior half of the lens vesicle differentiate into primary lens fiber cells, which form the lens fiber core, while cells in the anterior half maintain a proliferative state as a monolayer lens epithelium. After formation of the primary fiber core, lens epithelial cells start to differentiate into lens fiber cells at the interface between the lens epithelium and the primary lens fiber core, which is called the equator. Differentiating lens fiber cells elongate and cover the old lens fiber core, resulting in growth of the lens during development. Thus, lens fiber differentiation is spatially regulated and the equator functions as a platform that regulates the switch from cell proliferation to cell differentiation. Since the 1970s, the mechanism underlying lens fiber cell differentiation has been intensively studied, and several regulatory factors that regulate lens fiber cell differentiation have been identified. In this review, we focus on the lens equator, where these regulatory factors crosstalk and cooperate to regulate lens fiber differentiation. Normally, lens epithelial cells must pass through the equator to start lens fiber differentiation. However, there are reports that when the lens epithelium structure is collapsed, lens fiber cell differentiation occurs without passing the equator. We also discuss a possible mechanism that represses lens fiber cell differentiation in lens epithelium.

  10. Capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    Miguel Mu(n)oz-Navas

    2009-01-01

    Capsule endoscopy (CE) is a simple, safe, non-invasive, reliable technique, well accepted and tolerated by the patients, which allows complete exploration of the small intestine. The advent of CE in 2000 has dramatically changed the diagnosis and management of many diseases of the small intestine, such as obscure gastrointestinal bleeding, Crohn's disease, small bowel tumors, polyposis syndromes, etc. CE has become the gold standard for the diagnosis of most diseases of the small bowel. Lately this technique has also been used for esophageal and colonic diseases.

  11. 可植入胶原聚合透镜植入术后早期眼前段观察%Observation of anterior segment after implantation of implantable collamer lens in early stage

    Institute of Scientific and Technical Information of China (English)

    栗静; 刘磊; 李新宇; 王虎杰

    2014-01-01

    Objective To observe the anterior segment after implantation of implantable collamer lens (ICL) in early stage.Methods 65 eyes of 37 patients with high myopia who accepted ICL implantation were enrolled in this study.Anterior chamber volume (ACV),anterior chamber depth (ACD),iridocorneal angle,intraocular pressure (IOP) and endothelial cell density were measured at pre-operation,1 month and 6 months after surgery,and measurements were analyzed by statistical analysis.Results After surgeries,the ACD,iridocorneal angles and ACV decreased statistically significantly,and there were no statistical differences between measurements of 1 month and 6 months after surgery; the IOP measured at postoperative 1 month was lower than before and achieved stable state during postoperative 6 months; The endothelial cell density decreased about 4.75% and 6.87% respectively at postoperative 1 month and 6 months (P < 0.05) ; The mean central vault were (412.61 ± 192.94) μm and (365.69 ± 179.75) μm respectively at postoperative 1 month and 6 months,the ICLs had no contact with lens.Conclusion In the early period after implantation of ICL,the anterior segment morphology changed significantly,but these indexes were stable and no closure of iridocorneal angle or increasing of IOP were observed in the follow-up 6 months,therefore,long time follow-up is still required.%目的 观察有晶状体眼可植入胶原聚合透镜(ICL)植入术后早期的眼前段形态.方法 随机选取接受ICL植入术的高度近视37例(65只眼),测量患者术前、术后1个月和6个月的前房深度、前房角、前房容积、眼压和角膜内皮细胞密度,并对测量结果进行统计学分析.结果 术后前房深度、前房角和前房容积均较术前显著减小,术后1个月和术后6个月相比差异无统计学意义.术后1个月时眼压较术前稍有降低,术后6个月时恢复至术前水平;术后1个月和6个月患眼角膜内皮细胞密度较术前分别降低4

  12. Intraocular lens fixation with dacron.

    Science.gov (United States)

    Peyman, G A; Koziol, J E

    1978-10-01

    To overcome the problem of postoperative lens dislocation, we evaluated a new means of lens fixation. Our experimental studies in rabbits and primates demonstrated that Dacron polyethylene terephtalate induced a cellular reaction from either the anterior or posterior iris surface when placed in contact with the iris, thereby establishing a bond between the Dacron fibers and the iris. Dacron mesh can be attached to the distal portion of either the anterior or posterior loops of a Binkhorst iris clip (4-loop) lens. In the rabbit eye, lens fixation occurred within five days; in the primate eye, 30 days. When combined with silk, Dacron produced tissue ingrowth in the primate eye within 14 days. No unwanted reaction occurred in any animal with the Dacron and silk combination. Being biodegradable, the silk induced faster cellular ingrowth than the Dacron. However, Dacron, which is not biodegradable, provided a permanent means of fixation. PMID:155053

  13. Posterior capsule opacification and neovascularization treated with intravitreal bevacizumab and Nd:YAG capsulotomy

    Directory of Open Access Journals (Sweden)

    Grimelda Yuriana Sánchez-Castro

    2008-10-01

    Full Text Available Grimelda Yuriana Sánchez-Castro1, Alejandra Hitos-Fájer1, Erick Mendoza-Schuster1, Raul Velez-Montoya2, Cecilio Francisco Velasco-Barona11Asociación para Evitar la Ceguera en México. Hospital “Dr. Luis Sánchez Bulnes”, México, D.F. Ophthalmology Department – Anterior Segment; 2Asociación para Evitar la Ceguera en México. Hospital “Dr. Luis Sánchez Bulnes”, México, D.F. Ophthalmology Department – Retina departmentAbstract: We reported a 75-year-old diabetic man, who developed opacification and neovascularization of the posterior capsule after extracapsular cataract extraction and posterior chamber intraocular lens implantation. The patient was treated with two injections of 2.5 mg of intravitreal bevacizumab. The treatment produced an important regression of the posterior capsular new vessels, allowing us to perform a successful Nd:YAG capsulotomy, clearing the visual axis and improving the visualization of the posterior pole. Even though, best corrected visual acuity was 20/200 due to diabetic macular edema.Keywords: posterior capsule opacification, posterior capsule neovascularization, cataract surgery, postoperative complications, intravitreal bevacizumab

  14. Catarata polar anterior piramidal deslocada para a câmara anterior causando edema de córnea: relato de caso Corneal edema caused by a pyramidal anterior polar cataract dislocated to the anterior chamber: case report

    Directory of Open Access Journals (Sweden)

    Ramon Coral Ghanem

    2004-08-01

    Full Text Available Cataratas polares anteriores piramidais são opacidades cônicas que se projetam para a câmara anterior a partir da cápsula anterior do cristalino. Na grande maioria dos pacientes a opacidade permanece aderida e estável durante toda a vida. O objetivo deste trabalho é documentar uma manifestação incomum desse tipo de catarata: a deiscência espontânea das pirâmides para a câmara anterior causando descompensação endotelial e edema corneal bilateral. Relatamos o caso de uma paciente feminina, de 66 anos, branca, que apresentava edema corneal localizado inferiormente no olho direito associado à lesão nodular branco-esclerótica compatível com a pirâmide anterior da catarata polar. O olho esquerdo apresentava edema corneal difuso intenso e presença de uma catarata polar anterior com a região piramidal deslocada para a câmara anterior. Sabe-se que a pirâmide anterior pode permanecer inabsorvida na câmara anterior por longo período, pois é composta de tecido colágeno denso. Isto causa perda endotelial progressiva e edema corneal e deve ser considerada indicação de remoção cirúrgica da catarata polar anterior e de seu fragmento. Ressalta-se, também, a importância do bom senso no julgamento das cataratas polares anteriores, considerando-se tamanho da opacidade, simetria das opacidades e componente cortical associado, na tentativa de se evitar ambliopia.Pyramidal anterior polar cataracts are conical opacities that project into the anterior chamber from the anterior capsule of the lens. In the vast majority of patients the opacity remains bound and stable throughout life. We report an unusual complication of this type of cataract: spontaneous dehiscence of the pyramids to the anterior chamber causing bilateral endothelial damage and corneal edema. 66-year-old white woman presented with inferior corneal edema in the right eye and diffuse corneal edema in the left eye. A white nodular lesion was observed in the inferior angle

  15. In Vivo Positional Analysis of Implantable Collamer Lens Using Ultrasound Biomicroscopy

    Directory of Open Access Journals (Sweden)

    Ahmed Mohamed Kamal Elshafei

    2016-01-01

    Full Text Available Purpose. To evaluate the anterior segment, the anatomical position of the implantable collamer lenses (ICL, and its relationship to adjacent ocular structures using Ultrasound Biomicroscopy (UBM. Methods. In a prospective study, 142 myopic eyes of 93 patients implanted with Visian ICL were subjected to UBM examination between March 2010 and January 2015. The relative position of ICL to the adjacent structure and the overall iris configuration were evaluated. The machine calibers were used to measure the minimum central distance between the ICL and anterior lens capsule (vault and the vertical central distance between the corneal endothelium and the ICL (E-ICL. Results. The mean ICL vault was 376±105 μm. The mean E-ICL was 2826±331 μm. Contact between ICL and the posterior epithelium of the iris was present in all eyes. The overall iris configuration was flat in 89 eyes. Central anterior convexity was present in 41 eyes and mild peripheral iris bombe in 12 eyes. The haptics could be imaged in the ciliary sulcus in 112 eyes and at least one haptic resting on the lens periphery and zonules in 30 eyes. Conclusion. UBM can provide valuable anatomical information that allows detailed postoperative in vivo assessment of ICL.

  16. In Vivo Positional Analysis of Implantable Collamer Lens Using Ultrasound Biomicroscopy

    Science.gov (United States)

    Genaidy, Mahmoud Mohamed; Moharram, Hossam Mohamed

    2016-01-01

    Purpose. To evaluate the anterior segment, the anatomical position of the implantable collamer lenses (ICL), and its relationship to adjacent ocular structures using Ultrasound Biomicroscopy (UBM). Methods. In a prospective study, 142 myopic eyes of 93 patients implanted with Visian ICL were subjected to UBM examination between March 2010 and January 2015. The relative position of ICL to the adjacent structure and the overall iris configuration were evaluated. The machine calibers were used to measure the minimum central distance between the ICL and anterior lens capsule (vault) and the vertical central distance between the corneal endothelium and the ICL (E-ICL). Results. The mean ICL vault was 376 ± 105 μm. The mean E-ICL was 2826 ± 331 μm. Contact between ICL and the posterior epithelium of the iris was present in all eyes. The overall iris configuration was flat in 89 eyes. Central anterior convexity was present in 41 eyes and mild peripheral iris bombe in 12 eyes. The haptics could be imaged in the ciliary sulcus in 112 eyes and at least one haptic resting on the lens periphery and zonules in 30 eyes. Conclusion. UBM can provide valuable anatomical information that allows detailed postoperative in vivo assessment of ICL. PMID:27672446

  17. The Role of Type IV Collagen in Developing Lens in Mouse Fetuses

    Directory of Open Access Journals (Sweden)

    Mehdi Jalali

    2009-09-01

    Full Text Available Objective(sExtracellular matrix (ECM and basement membrane (BM play important roles in many developmental processes during development and after birth. Among the components of the BM, collagen fibers specially type IV are the most important parts. The aim of this study was to determine the time when collagen type IV appears in the BM of lens structure during mouse embryonic development.Materials and MethodsIn this experimental study, 22 female Balb/C mice were randomly selected and were kept under normal condition, finding vaginal plug was assumed as day zero of pregnancy. From embryonic day 10 to 20, all specimens were sacrificed by cervical dislocation and their heads were fixed, serially sectioned and immunohistochemistry study for tracing collagen type IV in lens were carried out.ResultsOur data revealed that collagen type IV appeared at the early stage of gestation day 12 in BM of anterior epithelial lens cells and the amount of this protein gradually increased until days 15-17 in ECM and posterior capsule epithelium. After this period, severe reaction was not observed in any part of the lens.ConclusionThese findings establish the important role of collagen IV in developing optic cup and any changes during critical period of pregnancy may be result in severe visual system defect

  18. Generation of Human Lens Epithelial-Like Cells From Patient-Specific Induced Pluripotent Stem Cells.

    Science.gov (United States)

    Li, Dan; Qiu, Xiaodi; Yang, Jin; Liu, Tianjin; Luo, Yi; Lu, Yi

    2016-12-01

    Cataractogenesis begins from the dynamic lens epithelial cells (LECs) and adjacent fiber cells. LECs derived from cell lines cannot maintain the crystalline expression as the primary LECs. The current study aimed to efficiently generate large numbers of human LECs from patient-specific induced pluripotent stem cells (iPSCs). Anterior lens capsules were collected from cataract surgery and were used to culture primary hLECs. iPSCs were induced from these primary hLECs by lentiviral transduction of Oct4, Sox2, Klf4, and c-Myc. Then, the generated iPSCs were re-differentiated into hLECs by the 3-step addition of defined factor combinations (Noggin, BMP4/7, bFGF, and EGF) modified from an established method. During the re-differentiation process, colonies of interest were isolated using a glass picking tool and cloning cylinders based on the colony morphology. After two steps of isolation, populations of LEC-like cells (LLCs) were generated and identified by the expression of lens marker genes by qPCR, western blot and immunofluorescence staining. The study introduced a modified protocol to isolate LLCs from iPSCs by defined factors in a short time frame. This technique could be useful for mechanistic studies of lens-related diseases. J. Cell. Physiol. 231: 2555-2562, 2016. © 2016 Wiley Periodicals, Inc. PMID:26991066

  19. Pupillary block glaucoma following implantation of a posterior chamber pseudophakos in the anterior chamber.

    Directory of Open Access Journals (Sweden)

    Mandal Anil

    2002-01-01

    Full Text Available Pupillary block glaucoma is a common complication of cataract surgery, especially following anterior chamber intraocular lens implantation. We report a case of pupillary block glaucoma with a posterior chamber IOL that was implanted in the anterior chamber following a complicated extracapsular cataract extraction. The case was successfully managed by explantation of the posterior chamber lens, anterior vitrectomy, peripheral iridectomy and secondary anterior chamber intraocular lens implantation. The intraocular pressure was controlled with a single topical antiglaucoma medication.

  20. Quantitative changes of anterior segment before and after implantable collamer lens implantation for high myopia with Pentacam anterior segment system%Pentacam评估高度近视有晶状体眼人工晶状体植入术前后眼前节形态的改变

    Institute of Scientific and Technical Information of China (English)

    周远香

    2015-01-01

    目的:通过眼前节全景分析仪( Pentacam)量化分析高度近视患者行ICL植入术手术前后眼前节形态的改变,评估手术的安全性、有效性。  方法:收集我院2011-09/2013-02高度近视眼行ICL植入手术的患者21例39眼,术后随访6~12mo。通过Pentacam分别测量术前;术后1wk;1,6mo的中央前房深度( ACD)、前房角度(ACA)、前房容积(ACV);记录术后1wk;1,6mo的ICL拱高(ICL-vault);记录术前裸眼视力(pre-UCVA)、最佳矫正视力( BCVA)、术后裸眼视力( post-UCVA)以及眼压值。使用SPSS18.0统计软件分析各项指标,术前、术后的资料均采用配对t检验进行统计学分析。  结果:术前;术后1wk;1,6mo 的ACD分别是3.27±0.22,3.02±0.33,2.98±0.31,2.98±0.32mm, ACA分别是(40.39±5.40)°,(26.70±4.47)°,(26.96±4.48)°,(26.95±4.45)°, ACV分别是207.74±25.43,122.87±17.58,128.05±17.84, ;128.64±17.50mm 3。术后1wk;1,6mo的拱高分别是0.49±0.13,0.46±0.13,0.46±0.14mm。术前与术后3个不同时段的ACD,ACA,ACV的值相比,其均存在统计学差异( P  结论:通过眼前节全景分析仪( Pentacam)分析发现ICL术后前房变浅,房角变窄,前房容积变小,但人工晶状体与透明晶状体之间仍拥有安全的间隙,ICL植入术治疗高度近视眼安全、有效,但远期疗效有待进一步观察。%•AlM: To analyze the quantitative changes of anterior segment by Pentacam anterior segment system and to evaluate the safety and effectiveness after implantable collamer lens ( lCL) implantation for high myopia. •METHODS:Twenty- one patients with 39 eyes were implanted lCL in our hospital from September 2011 to February 2013. The follow-up was 6 ~ 12mo. Central anterior chamber depth ( ACD ) , anterior chamber angle ( ACA) , anterior chamber volume ( ACV) were measured by Pentacam preoperatively, 1wk, 1 and 6mo postoperatively. The distance between crystal lens and lOL ( lCL- vault ) were measured at

  1. Incidência de opacificação de cápsula posterior em pacientes submetidos à facoemulsificação e implante de lentes intra-oculares acrílicas hidrofílicas expansíveis Incidence of posterior capsule opacification in patients submitted to phacoemulsification and expandable acrylic intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Hilton Arcoverde Gonçalves de Medeiros

    2006-06-01

    Full Text Available OBJETIVO: Avaliar prospectivamente os resultados das lentes intra-oculares de polímeros expansíveis implantadas em pacientes submetidos à facoemulsificação, quanto à incidência de opacificação de cápsula posterior, levando em consideração a biocompatibilidade das lentes expansíveis. MÉTODOS: O grupo de estudo foi composto por 830 pacientes, 1.200 olhos, que foram submetidos a facoemulsificação, utilizando a mesma técnica, variando-se apenas o diâmetro da capsulorrexe, pelo mesmo cirurgião, no período de 1998 a 2002, com implante de lente intra-ocular hidrofílica expansível. O acompanhamento médio foi de 2,4 anos, variando de seis meses a quatro anos. RESULTADOS: O número total de opacificação de cápsula posterior foi de 54 casos. CONCLUSÃO: A incidência de opacificação de cápsula posterior encontrada no grupo foi de 4,6%.PURPOSE: To evaluate prospectively the results of expandable acrylic intraocular lenses in patients submitted to phacoemulsification as regard posterior capsule opacification. METHODS: The study group consisted of 830 patients, 1,200 eyes that underwent phacoemulsification from 1998 to 2002, by the same surgeon, using the same technique but with different diameters of capsulorrhexis, with expandable hydrophilic acrylic intraocular lens implantation. The mean follow-up was 2.4 years, ranging from 6 months to 4 years. RESULTS: The total number of posterior capsule opacification was 54 cases. CONCLUSIONS: The incidence of posterior capsule opacification was 4.6% in these patients.

  2. Cervicoplastia anterior Anterior cervicoplasty

    Directory of Open Access Journals (Sweden)

    Lucas Gomes Patrocínio

    2004-10-01

    Full Text Available Muitos pacientes buscam correção estética da frouxidão da pele do pescoço, depósito de gordura na região submentoneana ou bandas de platisma. Em grande parte dos casos a ação medial, via cervicoplastia anterior é necessária. OBJETIVO: Demonstrar a casuística e avaliar os resultados e complicações com a técnica de cervicoplastia anterior no Serviço de Otorrinolaringologia da Universidade Federal de Uberlândia. FORMA DE ESTUDO: Relato de série. PACIENTES E MÉTODOS: Quarenta e dois pacientes, entre 39 e 65 anos de idade, sendo 40 (95,2% do sexo feminino e 2 (4,8% do masculino, foram submetidos a cervicoplastia anterior. Retrospectivamente foram avaliados resultados e complicações. RESULTADOS: Destes, 34 apresentaram resultados satisfatórios, 4 apresentaram déficit estético notado somente pelo cirurgião, 3 apresentaram déficit estético notado somente pelo paciente e 1 apresentou déficit estético necessitando cirurgia revisional. Ao estudo fotográfico, todos os pacientes apresentaram melhora do perfil cervical, redução das bandas de platisma e da frouxidão da pele, estabilização da musculatura cervical e acentuação do ângulo cervicomental, em graus variados. Houve complicação em 2 casos (discreto serohematoma e cicatriz um pouco alargada. CONCLUSÃO: A cervicoplastia, associada ou não à tração lateral pela ritidoplastia, é uma técnica que produz resultados satisfatórios na grande maioria dos casos.Many patients look for aesthetic correction of the laxity of neck skin, submandibular fat deposit or platisma bands. In a large part of the cases, medial action, through anterior cervicoplasty is necessary. AIM: To demonstrate the casuistic and to evaluate the results and complications with anterior cervicoplasty technique in the Otorhinolaryngology Service of the Federal University of Uberlândia. STUDY DESIGN: Serie report. PATIENTS AND METHODS: Forty-two patients, between 39 and 65 years of age, being 40 (95

  3. Anterior Segment Alterations and Comparative Aqueous Humor Proteomics in the Buphthalmic Rabbit (An American Ophthalmological Society Thesis)

    Science.gov (United States)

    Edward, Deepak P.; Bouhenni, Rachida

    2011-01-01

    Purpose To use an integrated proteohistologic approach to gain insight into the anterior segment alterations in the buphthalmic rabbit. Methods Eyes from 2- and 5-year-old buphthalmic and normal rabbits (n=20) were studied histologically. Liquid chromatography–tandem mass spectrometry (LC-MS/MS) of aqueous humor (AH) was used to determine differential protein expression between animal groups. Western blot and immunohistochemistry were performed on selected differentially expressed proteins identified by LC-MS/MS. Results The buphthalmic rabbits manifested a mild clinical phenotype with typical angle anomalies that appeared progressive by histology. Significantly thickened Descemet’s membrane (DM) and anterior lens capsule in all buphthalmic rabbits showed increased fibronectin and collagen-IV immunolabeling. LC-MS/MS applying stringent filtering criteria revealed significant differential expression of several AH proteins in these rabbits. The protein of interest in the 2-year-old group was histidine-rich glycoprotein, and those in the 5-year-old group included alpha-2-HS-glycoprotein, clusterin, apolipoprotein E, interphotoreceptor retinoid-binding protein, transthyretin, cochlin, gelsolin, haptoglobin, hemopexin, and beta-2 microglobulin. The proteomic data for selected proteins was validated by Western blot and immunohistochemistry. A wide range of functional groups were affected by the altered AH proteins. These included extracellular matrix modulation, regulation of apoptosis, oxidative stress, and protein transport. Conclusions Multiple anterior segment alterations were histologically identified in the buphthalmic rabbits that showed progressive changes with age. The differentially expressed AH proteins in these rabbits suggest a multifunctional role for AH in modulating pathologic changes in DM, anterior lens capsule, and the angular meshwork in these animals. PMID:22253484

  4. Contact lens management of keratoconus.

    Science.gov (United States)

    Downie, Laura E; Lindsay, Richard G

    2015-07-01

    Contact lenses are the primary form of visual correction for patients with keratoconus. Contemporary advances in contact lens designs and materials have significantly expanded the available fitting options for patients with corneal ectasia. Furthermore, imaging technology, such as corneal topography and anterior segment optical coherence tomography, can be applied to both gain insight into corneal microstructural changes and to guide contact lens fitting. This paper provides a comprehensive review of the range of contact lens modalities, including soft lenses, hybrid designs, rigid lenses, piggyback configurations, corneo-scleral, mini-scleral and scleral lenses that are currently available for the optical management of keratoconus. The review also discusses the importance of monitoring for disease progression in patients with keratoconus, in particular children, who tend to undergo more rapid progressive changes, so as to facilitate appropriate modification to contact lens fitting and/or potential referral for corneal collagen cross-linking treatment, as appropriate. PMID:26104589

  5. Changes of ocular anterior segment on morphology after implantation of the implantable collamer lens for high myopia%有晶状体眼后房型人工晶状体植入术后眼前节形态学观察

    Institute of Scientific and Technical Information of China (English)

    容维宁; 孙燕; 郭慧青; 徐惠芳; 贾沁; 梁静; 殷莉; 周玲婕; 盛迅伦

    2015-01-01

    Objective To assess the effect on anterior chamber angle,corneal endothelial and adjacent tissue after implantation of phakic posterior chamber implantable collamer lens (PPC-ICL) for the correction of high myopia.Methods In this prospective,nonrandomized clinical study,106 consecutive eyes of 58 patients with high myopic received ICL implantation between January 2011 and June 2013 in the Ningxia Eye Hospital.Uncorrected visual acuity (UCVA),best corrected visual acuity (BCVA),intraocular pressure,corneal endothelial cell count were measured preoperatively and at 1 month,6 months and 12 months postoperatively.The ultrasound biomicroscopy (UBM) was used to observe the depth of anterior chamber (ACD) vault,angle opening distance 500 microns from the scleral spur (AOD500),trabecular-iris angle (TIA) at point 2,4,8 and 10 respectively.The repeated measurement ANOVA was used to analyzed statistical data.Results The postoperative UCVA was equally or higher compare with preoperative BCVA in all patients.Intraocular pressure and corneal endothelial cell count were no statistically significant difference between pre-and postoperative (P>0.05).The postoperaive ACD,AOD500 and TIA value were decreased significantly than preoperative at 1 month (F=12.372,21.393,22.076,21.154,21.763,19.471,19.823,19.836,19.247,P<0.05).But there were no statistically significant difference of ACD,AOD500,vault and TIA between 1-month and 6-month,12-month postoperatively.No pupillary block glaucoma or anterior capsule opacification occurred during the follow-up.Conclusion The structure of anterior chamber angle was stable and corneal endothelial cell was no obvious decrease postoperatively during 1 year follow-up.%目的 观察有晶状体眼后房型人工晶状体(PPC-ICL)植入术治疗高度近视后眼前节形态学变化,探讨PPC-ICL植入术对前房角、角膜内皮以及邻近组织的影响.方法 前瞻性研究.收集2011年1月至2013年6月在宁夏眼科医院行PPC-ICL

  6. Pneumatic Capsule Pipeline

    OpenAIRE

    ECT Team, Purdue

    2007-01-01

    Pneumatic capsule pipeline (PCP) uses wheeled capsules (vehicles) to carry cargoes through a pipeline filled with air. Modern large diameter PCP systems utilize through flow booster pumps, also known as jet pump injectors. These create the pressure differentials required to propel multiple capsules through a pipeline, while allowing both terminals at atmospheric pressure. This is done by placing a booster pump midway along the pipeline, and designing it in such a way that capsules can bypass ...

  7. Morphological Findings of Intraocular Lens with Haptics Detached from Optics Following Cataract Surgery.

    Science.gov (United States)

    Suzuki, Yukihiko; Suzuki, Kaori; Metok, Tomomi; Nakazawai, Mitsuru

    2010-03-09

    A 55-year-old woman was treated using phacoemulsification, aspiration, and intraocular lens (IOL) implantation. Three months after surgery, the optical zone of the anterior capsule was completely closed due to strong capsular contractions. As the two haptics were found to be completely detached from the optics, the IOL was subsequently extracted and morphologically examined. Although the optics and haptics of the IOL when viewed with a stereomicroscope appeared to have no marked damage on their surfaces, an ultra-structural examination showed that a portion of the acrylic optics on the detached surface was defective. We considered that the IOL haptics might have become detached from the optics due to continuous force from postoperative capsular contractions.

  8. Goat′s eye integrated with a human cataractous lens: A training model for phacoemulsification

    Directory of Open Access Journals (Sweden)

    Sabyasachi Sengupta

    2015-01-01

    Full Text Available A relatively simple and inexpensive technique to train surgeons in phacoemulsification using a goat′s eye integrated with a human cataractous nucleus is described. The goat′s eye is placed on a bed of cotton within the lumen of a cylindrical container. This is then mounted on a rectangular thermocol so that the limbus is presented at the surgical field. After making a clear corneal entry with a keratome, the trainer makes a 5-5.5 mm continuous curvilinear capsulorhexis in the anterior lens capsule, creates a crater of adequate depth in the cortex and inserts the human nucleus within this crater in the goat′s capsular bag. The surgical wound is sutured, and the goat′s eye is ready for training. Creating the capsulorhexis with precision and making the crater of adequate depth to snugly accommodate the human nucleus are the most important steps to prevent excessive wobbling of the nucleus while training.

  9. Colon capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    Ignacio Fernandez-Urien; Cristina Carretero; Ana Borda; Miguel Mu(n)oz-Navas

    2008-01-01

    Wireless capsule endoscopy has become the first imaging tool for small bowel examination.Recently,new capsule endoscopy applications have been developed,such as esophageal capsule endoscopy and colon capsule endoscopy.Clinical trials results have shown that colon capsule endoscopy is feasible,accurate and safe in patients suffering from colonic diseases.It could be a good alternative in patients refusing conventional colonoscopy or when it is contraindicated.Upcoming studies are needed to demonstrate its utilty for colon cancer screening and other indications such us ulcerative colitis.Comparative studies including both conventional and virtual colonoscopy are also required.

  10. Esophageal capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    Ignacio Fernandez-Urien; Cristina Carretero; Raul Armendariz; Miguel Mu(n)oz-Navas

    2008-01-01

    Capsule endoscopy is now considered as the first imaging tool for small bowel examination.Recently,new capsule endoscopy applications have been developed,such as esophageal capsule endoscopy and colon capsule endoscopy.Esophageal capsule endoscopy in patients with suspected esophageal disorders is feasible and safe,and could be also an alternative procedure in those patients refusing upper endoscopy.Although large-scale studies are needed to confirm its utility in GERD and cirrhotic patients,current results are encouraging and open a new era in esophageal examination.

  11. The effect of lens parameters on the development of the primary angle-closure glaucoma

    Institute of Scientific and Technical Information of China (English)

    Zhaohui Feng; Naixue Sun; Aiyi Zhou; Donggang Han; Yun Long; Zhao Wang; Xiaohua Wang

    2007-01-01

    Objective:To investigate the role the lens dimensions played on the pathogenesis of primary angle-closure glaucoma.Methods:38 eyes of 20 patients with primary angle-closure glaucoma (PACG) and 35 eyes of 22 normal individuals without ocular abnormalities were examined. The anatomical parameters of the lens and other structures of the anterior segment were calculated using B ultrasound, computer image processing and ultrasound biomicroscopy (UBM). The parameters were compared between the patients and normal subjects. Correlation analysis was used to determine the relationship between the radii of curvature of the anterior lens surface (RCALS) and the other parameters of the anterior segment. Results:Compared with the normal eyes, the eyes of PACG had thicker lens, steeper curvature of anterior lens surface, decreased depth of the anterior chamber, narrower chamber angle, and more anterior position of the ciliary bodies and lens. All these differences were significant(P < 0.05 or P < 0.01). In the PACG group, the RCALS had significantly negative correlation with the central and peripheral lens thickness (P < 0.01 and P < 0.05 respectively), and had positive correlation with relative lens position, anterior chamber depth (ACD), angle-open distance at 500 um(AOD500), trabecular iris angle(TIA) and trabecular ciliary processes distance(TCPD, P < 0.05 or P < 0.01 ). Conclusion:The occurrence of PACG is relevant to the abnormal anatomical structures of the anterior segment. Among all factors, the lens parameters play an important role in the pathogenesis. Increased lens thickness, relative more anterior position of lens, especially steepened curvature of anterior lens surface are predisposing factors of the pathologic phenomenon in PACG including pupillary blockage, shallow anterior chamber, secondary closure of chamber angle and elevation of intraocular pressure.

  12. Development of lens sutures.

    Science.gov (United States)

    Kuszak, Jer R; Zoltoski, Rebecca K; Tiedemann, Clifford E

    2004-01-01

    Cylindrical map projections (CMPs) have been used for centuries as an effective means of plotting the features of a 3D spheroidal surfaces (e.g. the earth) on a 2D rectangular map. We have used CMPs to plot primate fiber cell organization from selected growth shells as a function of growth, development and aging. Lens structural parameters and features were derived from slit-lamp, light and transmission and scanning electron micrographs. This information was then used to create CMPs of lenses that were then correlated with azimuthal map projections (AMPs; projections that are radially symmetric around a central point [the poles]) to reveal different suture patterns during distinct time periods. In this manner, both lens fiber and suture branch locations are defined by degrees of longitude and latitude. CMPs and AMPs confirm that throughout defined periods of development, growth and ageing, increasingly complex suture patterns are formed by the precise ordering of straight and opposite end curvature fibers. However, the manner in which additional suture branches are formed anteriorly and posteriorly is not identical. Anteriorly, new branches are added between extant branches. Posteriorly, pairs of new branches are formed that progressively overlay extant branches. The advantage of using CMPs is that the shape and organization of every fiber in a growth shell can be observed in a single image. Thus, the use of CMPs to plot primate fiber cell organization has revealed more complex aspects of fiber formation that may explain, at least in part, changes in lens optical quality as a function of age and pathology. In addition, more accurate measurements of fiber length will be possible by incorporating the latitudinal and longitudinal locations of fibers. PMID:15558480

  13. 有晶状体眼后房型人工晶状体植入术后前房及前房角的超声活体显微镜观察%Observation on changes of anterior chamber and chamber angle structures after posterior chamber phakic intraocular lens implantation by ultrasound biomicroscopy

    Institute of Scientific and Technical Information of China (English)

    汪晓宇; 沈晔; 杜持新; 李毓敏; 董映

    2009-01-01

    Objective To study the changes of anterior chamber and chamber angle structures after implantable contact lens (ICL) implantation in high myopia by using ultrasound biomicroscopy (UBM).Methods A prospective series case study was conducted on 15 high myopia patients (30 eyes) treated with ICL implant.These patients were followed for one year postoperatively.Intraocular pressure (IOP) was measured by Goldmann applanation tonometer after surgery.All eyes were examined by UBM one year after the surgery.Central anterior chamber depth (ACD), trabecular-iris angle (TIA), the distance between the posterior surface of ICL and the lens and the distance between peripheral surface of ICL and the lens were measured.Nonparametric test was used to compare TIA.One-way ANOVA was used to assess the distance between peripheral surface of ICL and the lens.Repeated Measure ANOVA and Bonferroni test was performed to compare the IOP level before and after surgery.Paired t-test was used to compare ACD.Results Intraocular pressure changed from (13.75±2.27) mm Hg(1 mm Hg=0.133 kPa) preoperatively to (14.27±1.70), (14.70±2.07), (14.07±2.24), (14.00±2.69) and (13.97±2.95) mm Hg at 1 week, 1,3, 6 and 12 months after the surgery, respectively.There was a statistically significant increase of the IOP one month after the surgery, which was normalized completely at 3 months after surgery.The distances between central posterior surface of the cornea to the ICL and the lens were (2.24±0.21 ) and (2.97±0.11) mm, respectively.There was significant difference between these two data (t=20.63, P30°,ICL周边部与晶状体之间的距离在钟表位12:00、3:00、6:00、9:00位差异无统计学意义.ICL后表面与晶状体之间的距离为(0.63±0.16)mm,ICL与晶状体无接触.结论 ICL植入术后ICL位于晶状体前,致使术后中央ACD变浅、部分手术眼前房角宽度变窄.ICL与晶状体无接触,与虹膜后表面接触.

  14. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory of probabil......Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory...

  15. Measurement of Crystalline Lens Volume During Accommodation in a Lens Stretcher

    Science.gov (United States)

    Marussich, Lauren; Manns, Fabrice; Nankivil, Derek; Maceo Heilman, Bianca; Yao, Yue; Arrieta-Quintero, Esdras; Ho, Arthur; Augusteyn, Robert; Parel, Jean-Marie

    2015-01-01

    Purpose To determine if the lens volume changes during accommodation. Methods The study used data acquired on 36 cynomolgus monkey lenses that were stretched in a stepwise fashion to simulate disaccommodation. At each step, stretching force and dioptric power were measured and a cross-sectional image of the lens was acquired using an optical coherence tomography system. Images were corrected for refractive distortions and lens volume was calculated assuming rotational symmetry. The average change in lens volume was calculated and the relation between volume change and power change, and between volume change and stretching force, were quantified. Linear regressions of volume-power and volume-force plots were calculated. Results The mean (±SD) volume in the unstretched (accommodated) state was 97 ± 8 mm3. On average, there was a small but statistically significant (P = 0.002) increase in measured lens volume with stretching. The mean change in lens volume was +0.8 ± 1.3 mm3. The mean volume-power and volume-load slopes were −0.018 ± 0.058 mm3/D and +0.16 ± 0.40 mm3/g. Conclusions Lens volume remains effectively constant during accommodation, with changes that are less than 1% on average. This result supports a hypothesis that the change in lens shape with accommodation is accompanied by a redistribution of tissue within the capsular bag without significant compression of the lens contents or fluid exchange through the capsule. PMID:26161985

  16. 关节镜下盂唇修补与关节囊复合部分肩胛下肌紧缩修复复发性肩关节前脱位%Arthroscopic glenoid labrum repair and combined joint capsule and partial subscapularis suture for recurrent anterior shoulder dislocation

    Institute of Scientific and Technical Information of China (English)

    徐斌; 涂俊

    2015-01-01

    BACKGROUND:Arthroscopic glenoid labrum repair is the main therapy for recurrent anterior shoulder dislocation, which cannot meet the demands of shoulder stability. How to strengthen the anterior shoulder stability is an issue that is always explored and pursued. OBJECTIVE:To explore the effectiveness of arthroscopic glenoid labrum repair and combined joint capsule and partial subscapularis suture for recurrent anterior shoulder dislocation. METHODS:Seventy patients admitted for recurrent anterior shoulder dislocation at the Department of Orthopedics, First Affiliated Hospital of Anhui Medical University in China from October 2010 to August 2013 were enroled, who received the arthroscopic glenoid labrum repair and combined joint capsule and partial subscapularis suture. Patients undergoing post-operative systematical rehabilitation were folowed up for Constant-Murley Score and the ROWE Score for Instability, and shoulder stability and motor functions were evaluated in patients. RESULTS AND CONCLUSION: The 70 patients were folowed-up for 11-46 months. Complications only appeared in one patient with acute pulmonary edema and five patients with elbow or forearm skin blisters, but al were cured by treatment. Anterior shoulder dislocation disappeared postoperatively in al patients. Sixty-five patients almost recovered in the range of motion of the shoulder, who were satisfied with normal life and work activity. Al the patients returned to work. At the last folow-up, the Constant-Murley score was improved from 71.2±5.3 to 94.3±4.9, and the ROWE score was increased from 32.1±4.2 to 95.1±4.7, both of which were better than before (P < 0.05). This study demonstrated arthroscopic glenoid labrum repair and combined joint capsule and partial subscapularis suture is better for recurrent anterior shoulder dislocation, which is conductive to shoulder stability and motor function recovery.%背景:复发性肩关节前脱位的修复目前以关节镜下盂唇修补为主,

  17. 折叠式人工晶状体囊袋内植入后偏心与倾斜的临床研究%Decentration and tilt of foldable intraocular lenses in the lens capsule

    Institute of Scientific and Technical Information of China (English)

    方艳文; 卢奕; 汪琳

    2008-01-01

    目的 比较目前临床上常用的四种折叠式人工晶状体(intraocular lens,IOL)在囊袋内植入后偏心与倾斜的差异.方法 对65例/眼单纯性白内障患者进行术后3个月的随访.这些患者分别植入了一体式疏水丙烯酸酯IOL(SA60AT,Alcon)、三体式疏水丙烯酸酯IOL(AR40e,AMO)、三点固定式亲水丙烯酸酯IOL(XISTABI,IOLTECH)及四点固定式亲水丙烯酸酯IOL(QUATTRO SE,Corneal).用眼前节成像系统Pentacam(Oculus) 集各眼的Scheimpflug图像,用图像分析的方法得出IOL的偏心值与倾斜度.结果 SA60AT、AR40e、XLSTABI、QUATTRO SE四组患者IOL的平均偏心值分别为(281.49±169.58)ìm、(346.35±177.08)ìm、(531.33±254.70)ìm、(360.59±185.91)ìm,其差异有显著统计学意义(P=0.0100).四组患者IOL的倾斜度的中位数分别为0.98°(0.70°~1.73°)、1.33°(0.86°~1.83°)、1.50°(0.80°~2.68°)、1.38°(0.94°~2.37°),其差异无统计学意义(P=0.3885).四组患者的最佳矫正视力和对比敏感度差异无统计学意义(P>0.05).结论 四种IOL囊袋内植入后在倾斜度方面无差异,而在居中性方面,SA60AT优于XLSTABI,其他各种IOL间两两比较均无明显差异.

  18. Use of pars plana vitrectomy with phacoemulsification in vitreous cavity to treat complete posterior dislocation of lens

    Directory of Open Access Journals (Sweden)

    Mutoh T

    2011-07-01

    Full Text Available Tetsuya Mutoh, Yukihiro Matsumoto, Makoto ChikudaDepartment of Ophthalmology, Dokkyo Medical University Koshigaya Hospital, Koshigaya, Saitama, JapanBackground: The purpose of this study was to evaluate pars plana vitrectomy (PPV with phacoemulsification in the vitreous cavity for treatment of complete posterior dislocation of the lens without any damage to the lens capsule.Methods: We evaluated factors such as cause of dislocation, scleral fixation of an intraocular lens (IOL, preoperative and postoperative visual acuity, corneal endothelial cell density, and intraoperative and postoperative complications.Results: Displacement in the eleven eyes studied was mostly caused by ocular trauma and was idiopathic (four eyes each. Scleral fixation of the IOL was performed in seven of the eyes during first-time PPV. Visual acuity was improved in two eyes, unchanged in eight eyes, and worse in one eye. Mean corneal endothelial cell density was 2485 cells/mm2 preoperatively and 2301 cells/mm2 postoperatively. No significant differences were seen before and after the surgeries (P = 0.15, paired t-test. Intraoperative complications included retinal detachment and suprachoroidal hemorrhage in one eye each. The most common postoperative complication was transient ocular hypertension, which occurred in three eyes. IOL dislocation and vitreous incarceration of the anterior chamber in one eye required a second operation, while retinal detachment in one eye required a third operation.Conclusion: When treating a completely dislocated lens, prevention of retinal detachment which subsequently can affect the visual prognosis is the most important factor to be addressed after PPV with intravitreal phacoemulsification.Keywords: lens dislocation, pars plana vitrectomy, phacoemulsification in the vitreous cavity, retinal detachment

  19. The Zonules Selectively Alter the Shape of the Lens During Accommodation Based on the Location of Their Anchorage Points

    Science.gov (United States)

    Nankivil, Derek; Maceo Heilman, Bianca; Durkee, Heather; Manns, Fabrice; Ehrmann, Klaus; Kelly, Shawn; Arrieta-Quintero, Esdras; Parel, Jean-Marie

    2015-01-01

    Purpose. To determine the role of anterior and posterior zonular tension on the optomechanical lens response during accommodation simulation. Methods. Ten eyes from nine hamadryas baboons (4.9 ± 0.7 years) and 20 eyes from 18 cynomolgus monkeys (5.4 ± 0.3 years) were dissected, leaving the lens, zonules, ciliary body, hyaloid membrane, anterior vitreous, and a segmented scleral rim intact. The lens preparation was mounted in a lens stretcher, and the outer scleral shell was displaced radially in a stepwise fashion. The load, lens, and ciliary body diameters, lens power, lens thickness, and the anterior and posterior radius of curvature were measured during stretching. The zonular fibers attached to either the posterior or anterior lens surface were then carefully transected and the experiment was repeated. Zonular transection was confirmed in four eyes via laser scanning confocal microscopy after immunostaining. The effect of zonular transection on the tissue response to stretching was quantified. Results. Without anterior zonules, 48% and 97% of the changes in anterior and posterior radii are retained. Without posterior zonules, 81% and 67% of the changes in anterior and posterior radii are retained. The changes in lens shape were reduced after transecting either the anterior or posterior zonules; however, both surfaces still changed shape. Conclusions. While either the anterior or posterior zonules alone are capable of changing the shape of both lens surfaces, the anterior zonules have a greater effect on the anterior lens surface, and the posterior zonules have a greater effect on the posterior lens surface. PMID:25698707

  20. Cx43, ZO-1, alpha-catenin and beta-catenin in cataractous lens epithelial cells

    Indian Academy of Sciences (India)

    Anshul I Arora; Kaid Johar; Devarshi U Gajjar; Darshini A Ganatra; Forum B Kayastha; Anuradha K Pal; Alpesh R Patel; Rajkumar S; Abhay R Vasavada

    2012-12-01

    Specimens of the anterior lens capsule with an attached monolayer of lens epithelial cells (LECs) were obtained from patients (=52) undergoing cataract surgery. Specimens were divided into three groups based on the type of cataract: nuclear cataract, cortical cataract and posterior subcapsular cataract (PSC). Clear lenses (=11) obtained from donor eyes were used as controls. Expression was studied by immunofluorescence, real-time PCR and Western blot. Statistical analysis was done using the student’s -test. Immunofluorescence results showed punctate localization of Cx43 at the cell boundaries in controls, nuclear cataract and PSC groups. In the cortical cataract group, cytoplasmic pools of Cx43 without any localization at the cell boundaries were observed. Real-time PCR results showed significant up-regulation of Cx43 in nuclear and cortical cataract groups. Western blot results revealed significant increase in protein levels of Cx43 and significant decrease of ZO-1 in all three cataract groups. Protein levels of alpha-catenin were decreased significantly in nuclear and cortical cataract group. There was no significant change in expression of beta-catenin in the cataractous groups. Our findings suggest that ZO-1 and alpha-catenin are important for gap junctions containing Cx43 in the LECs. Alterations in cell junction proteins may play a role during formation of different types of cataract.

  1. Management of adhesive capsulitis

    OpenAIRE

    Neviaser, Andrew

    2015-01-01

    Kristen L Stupay,1 Andrew S Neviaser2 1Tulane University School of Medicine, New Orleans, LA, USA; 2George Washington University Medical Faculty Associates, Washington, DC, USA Abstract: Adhesive capsulitis of the shoulder is a condition of capsular contracture that reduces both active and passive glenohumeral motion. The cause of adhesive capsulitis is not known but it is strongly associated with endocrine abnormalities such as diabetes. Diverse terminology and the absence of definitive cri...

  2. Scheimpflug imaging of pediatric posterior capsule rupture

    Directory of Open Access Journals (Sweden)

    Grewal Dilraj

    2009-01-01

    Full Text Available We report a case of an 11-year-old boy who presented two days after blunt trauma to the left eye with a slingshot. On examination his best corrected visual acuity (BCVA was 20/20 in the right eye and 20/400 in the left eye. Slit-lamp examination of the left eye revealed a Vossius ring, traumatic cataract, traumatic posterior capsule tear (PCT. The contour of the posterior capsule bulge corresponded to the edges of the PCT. Rotating Scheimpflug imaging (Pentacam 70700:Oculus, Wetzlar Germany confirmed the traumatic cataract in the region of the PCT visualized as increased lens density at the cortex-vitreous interface. The extent of the PCT in the greatest and least dimensions was documented before and after intraocular lens (IOL implantation. Intra-operatively, the PCT was evident and phaco-emulsification with an IOL implant was performed. Postoperatively, his BCVA improved to 20/20 in the left eye with a well-centered in-the-bag IOL as found on slit-lamp and Scheimpflug images.

  3. Diabetes and contact lens wear.

    Science.gov (United States)

    O'Donnell, Clare; Efron, Nathan

    2012-05-01

    The literature suggests that diabetic patients may have altered tear chemistry and tear secretion as well as structural and functional changes to the corneal epithelium, endothelium and nerves. These factors, together with a reported increased incidence of corneal infection, suggest that diabetic patients may be particularly susceptible to developing ocular complications during contact lens wear. Reports of contact lens-induced complications in diabetic patients do exist, although a number of these reports concern patients with advanced diabetic eye disease using lenses on an extended wear basis. Over the past decade or so, there have been published studies documenting the response of the diabetic eye to more modern contact lens modalities. The results of these studies suggest that contact lenses can be a viable mode of refractive correction for diabetic patients. Furthermore, new research suggests that the measurement of tear glucose concentration could, in future, be used to monitor metabolic control non-invasively in diabetic patients. This could be carried out using contact lenses manufactured from hydrogel polymers embedded with glucose-sensing agents or nanoscale digital electronic technology. The purpose of this paper is to review the literature on the anterior ocular manifestations of diabetes, particularly that pertaining to contact lens wear. PMID:22537249

  4. Intracapsular dexamethasone implant in patients undergoing phacoemulsification and intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Lucas Monferrari Monteiro Vianna

    2013-08-01

    Full Text Available PURPOSE: To relate the outcomes of 7 eyes of 7 patients in which a dexamethasone 0.7 mg implant (Ozurdex® was placed inside the capsule bag after phacoemulsification and intraocular lens (IOL implantation and compare with the fellow eyes, that were operated by the same technique and received dexamethasone eyedrops in the post-operatory. METHODS: Report review of 7 eyes of 7 patients who received dexamethasone 0.7 mg implant after phacoemulsification and IOL, comparing them to the fellow eyes. All the patients underwent bilateral cataract surgery, with one month interval, by the same technique and by experienced surgeons, without complications. Post operatory medication consisted of moxifloxacin eye drops for all the 14 eyes and topic dexamethasone for the 7 eyes that did not received the implant. RESULTS: Nuclear cataract classification (according to LOCS III was 3.28 ± 0.69 in the implant eye group and 3.14 ± 0.83 in the fellow eye group. Postoperative best spectacle correct visual acuity (BSCVA was 0.85 ± 0.12 and 0.87 ± 0.13, respectively in the implant and fellow eye groups. The intraocular pressure remained stable and similar to the pre-operative measurements. Anterior chamber reaction and cornea edema were similar in both groups in the follow-up. Two of the four no sutured pellet migrated to the anterior chamber during the first post-operative week and had to be repositioned. Another no sutured pellet dislocated and remained partially inside the capsule bag. The 3 patients with IOL haptic-sutured pellet had no complications. CONCLUSIONS: In the present study, dexamethasone 0.7mg implant were effective in controlling the inflammation after phacoemulsification and IOL implantation, with no significant side effects.

  5. The effect of postoperative central vault on the anterior chamber after implantation of implantable contact lens V4c%有晶体眼后房型人工晶体 V4c 植入术后拱高对前房结构的影响

    Institute of Scientific and Technical Information of China (English)

    叶进; 袁长明; 王霁雪; 谢汉平

    2015-01-01

    目的:观察有晶体眼后房型人工晶体 V4c 植入术后拱高对前房结构的影响。方法对重庆普瑞眼科医院2014年11月2日至2015年2月5日开展的56眼有晶体眼后房型人工晶体 V4c 植入术进行回顾性研究。术前用房角镜检查房角并记录前房角色素分级,用 Pentacam 测量平均前房角宽度(ACA )、前房容积(ACV )。术后第1、3、6个月复诊时测量中央拱高和平均ACA 以及 ACV ,并记录前房角色素分级。对患者手术后3次复查的拱高与 ACA 减小的量、ACV 减小的量进行相关性分析。结果术后1个月56眼的拱高为250~765μm ,ACA 减小的量为(13.67±1.67)°,ACV 减小量为(94.23±17.02)mm3。术后第3个月55眼的拱高为239~761μm ,ACA 减小的量为(13.70±1.68)°,ACV 减小量为(93.6±17.48)mm3。术后第6个月51眼拱高为246~761μm ,ACA 减小的量为(13.60±1.69)°,ACV 减小量为(94.29±17.80)mm3。未发现色素为Ⅱ级的病例。将3次复查的中央拱高与 ACA 和 ACV 减小量进行相关性分析,呈正相关(P<0.05)。中央拱高越大,则 ACA 和 ACV 改变量越大。结论有晶体眼后房型人工晶体 V4c 植入术后前房角变窄,前房容积下降。中央拱高与 ACA 和 ACV 改变量呈正相关,合适的拱高对保持房角开放有积极的临床意义。%Objective To observe the effect of postoperative central vault on the anterior chamber after implantation of im-plantable contact lens V4c .Methods To carry out a retrospective study of 56 eyes with implantable contact lens V4c implantation in Chongqing Bright Eye Hospital from November 2 ,2014 to February 5 ,2015 ,examined anterior chamber angle before surgery ,the anterior chamber angular width (ACA) and anterior chamber volume (ACV) were measured by pentacam .the postoperative central vault and ACA and ACV during the first and third and sixth months after surgery

  6. Quadriceps muscle contraction protects the anterior cruciate ligament during anterior tibial translation.

    Science.gov (United States)

    Aune, A K; Cawley, P W; Ekeland, A

    1997-01-01

    The proposed skiing injury mechanism that suggests a quadriceps muscle contraction can contribute to anterior cruciate ligament rupture was biomechanically investigated. The effect of quadriceps muscle force on a knee specimen loaded to anterior cruciate ligament failure during anterior tibial translation was studied in a human cadaveric model. In both knees from six donors, average age 41 years (range, 31 to 65), the joint capsule and ligaments, except the anterior cruciate ligament, were cut. The quadriceps tendon, patella, patellar tendon, and menisci were left intact. One knee from each pair was randomly selected to undergo destructive testing of the anterior cruciate ligament by anterior tibial translation at a displacement rate of 30 mm/sec with a simultaneously applied 889 N quadriceps muscle force. The knee flexion during testing was 30 degrees. As a control, the contralateral knee was loaded correspondingly, but only 5 N of quadriceps muscle force was applied. The ultimate load for the knee to anterior cruciate ligament failure when tested with 889 N quadriceps muscle force was 22% +/- 18% higher than that of knees tested with 5 N of force. The linear stiffness increased by 43% +/- 30%. These results did not support the speculation that a quadriceps muscle contraction contributes to anterior cruciate ligament failure. In this model, the quadriceps muscle force protected the anterior cruciate ligament from injury during anterior tibial translation.

  7. NIF capsule performance modeling

    Directory of Open Access Journals (Sweden)

    Weber S.

    2013-11-01

    Full Text Available Post-shot modeling of NIF capsule implosions was performed in order to validate our physical and numerical models. Cryogenic layered target implosions and experiments with surrogate targets produce an abundance of capsule performance data including implosion velocity, remaining ablator mass, times of peak x-ray and neutron emission, core image size, core symmetry, neutron yield, and x-ray spectra. We have attempted to match the integrated data set with capsule-only simulations by adjusting the drive and other physics parameters within expected uncertainties. The simulations include interface roughness, time-dependent symmetry, and a model of mix. We were able to match many of the measured performance parameters for a selection of shots.

  8. Acid phosphatase and lipid peroxidation in human cataractous lens epithelium

    Directory of Open Access Journals (Sweden)

    Vasavada Abhay

    1993-01-01

    Full Text Available The anterior lens epithelial cells undergo a variety of degenerative and proliferative changes during cataract formation. Acid phosphatase is primarily responsible for tissue regeneration and tissue repair. The lipid hydroperoxides that are obtained by lipid peroxidation of polysaturated or unsaturated fatty acids bring about deterioration of biological membranes at cellular and tissue levels. Acid phosphatase and lipid peroxidation activities were studied on the lens epithelial cells of nuclear cataract, posterior subcapsular cataract, mature cataract, and mixed cataract. Of these, mature cataractous lens epithelium showed maximum activity for acid phosphatase (516.83 moles of p-nitrophenol released/g lens epithelium and maximum levels of lipid peroxidation (86.29 O.D./min/g lens epithelium. In contrast, mixed cataractous lens epithelium showed minimum activity of acid phosphatase (222.61 moles of p-nitrophenol released/g lens epithelium and minimum levels of lipid peroxidation (54.23 O.D./min/g lens epithelium. From our study, we correlated the maximum activity of acid phosphatase in mature cataractous lens epithelium with the increased areas of superimposed cells associated with the formation of mature cataract. Likewise, the maximum levels of lipid peroxidation in mature cataractous lens epithelium was correlated with increased permeability of the plasma membrane. Conversely, the minimum levels of lipid peroxidation in mixed cataractous lens epithelium makes us presume that factors other than lipid peroxidation may also account for the formation of mixed type of cataract.

  9. Contact lens in keratoconus

    Directory of Open Access Journals (Sweden)

    Varsha M Rathi

    2013-01-01

    Full Text Available Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP lenses, soft and soft toric lenses, piggy back contact lenses (PBCL, hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL.

  10. Anterior Eye Imaging with Optical Coherence Tomography

    Science.gov (United States)

    Huang, David; Li, Yan; Tang, Maolong

    The development of corneal and anterior segment optical coherence tomography (OCT) technology has advanced rapidly in recently years. The scan geometry and imaging wavelength are both important choices to make in designing anterior segment OCT systems. Rectangular scan geometry offers the least image distortion and is now used in most anterior OCT systems. The wavelength of OCT light source affects resolution and penetration. An optimal choice of the OCT imaging wavelength (840, 1,050, or 1,310 nm) depends on the application of interest. Newer generation Fourier-domain OCT technology can provide scan speed 100-1000 times faster than the time-domain technology. Various commercial anterior OCT systems are available on the market. A wide spectrum of diagnostic and surgical applications using anterior segment OCT had been investigated, including mapping of corneal and epithelial thicknesses, keratoconus screening, measuring corneal refractive power, corneal surgery planning and evaluation in LASIK, intracorneal ring implantation, assessment of angle closure glaucoma, anterior chamber biometry and intraocular lens implants, intraocular lens power calculation, and eye bank donor cornea screening.

  11. Wireless capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    A Mata; J Llach; JM Bordas

    2008-01-01

    Wireless capsule endoscopy is a new technique that allows complete exploration of the small bowel without external wires. Its role has been analyzed in many small bowel diseases such as obscure gastrointestinal bleeding, Crohn's disease and gastrointestinal polyposis syndromes with promising results. Studies on other pathologies (I.e. Small bowel tumour, celiac disease) are under evaluation to define the role of this technique.

  12. Management of adhesive capsulitis

    Directory of Open Access Journals (Sweden)

    Stupay KL

    2015-08-01

    Full Text Available Kristen L Stupay,1 Andrew S Neviaser2 1Tulane University School of Medicine, New Orleans, LA, USA; 2George Washington University Medical Faculty Associates, Washington, DC, USA Abstract: Adhesive capsulitis of the shoulder is a condition of capsular contracture that reduces both active and passive glenohumeral motion. The cause of adhesive capsulitis is not known but it is strongly associated with endocrine abnormalities such as diabetes. Diverse terminology and the absence of definitive criteria for diagnosis make evaluating treatment modalities difficult. Many treatment methods have been reported, most with some success, but few have been proved to alter the natural course of this disease. Most afflicted patients will achieve acceptable shoulder function without surgery. Those who remain debilitated after 8–12 months are reasonable candidates for invasive treatments. Here, the various treatment methods and the data to support their use are reviewed. Keywords: frozen shoulder, stiff shoulder, periarthritis, painful shoulder 

  13. Capsule-train stability

    Science.gov (United States)

    Bryngelson, Spencer H.; Freund, Jonathan B.

    2016-07-01

    Elastic capsules flowing in small enough tubes, such as red blood cells in capillaries, are well known to line up into regular single-file trains. The stability of such trains in somewhat wider channels, where this organization is not observed, is studied in a two-dimensional model system that includes full coupling between the viscous flow and suspended capsules. A diverse set of linearly amplifying disturbances, both long-time asymptotic (modal) and transient (nonmodal) perturbations, is identified and analyzed. These have a range of amplification rates and their corresponding forms are wavelike, typically dominated by one of five principal perturbation classes: longitudinal and transverse translations, tilts, and symmetric and asymmetric shape distortions. Finite-amplitude transiently amplifying perturbations are shown to provide a mechanism that can bypass slower asymptotic modal linear growth and precipitate the onset of nonlinear effects. Direct numerical simulations are used to verify the linear analysis and track the subsequent transition of the regular capsule trains into an apparently chaotic flow.

  14. Contact Lens Solution Toxicity

    Science.gov (United States)

    ... rash and rashes clinical tools newsletter | contact Share | Contact Lens Solution Toxicity Information for adults A A A This image shows a reaction to contact lens solution. The prominent blood vessels and redness ...

  15. Application of Foldable Intraocular Lens in Multiple Types of Cataract

    Institute of Scientific and Technical Information of China (English)

    Songtao Yuan; Qinghuai Liu; Qing Jiang; Nanrong Yuan

    2002-01-01

    Objective: To evaluate the clinical results of implantation of foldable intraocular lens inmultiple types of cataract.Methods: This retrospective study comprised 162 eyes of 148 patients undergoingphacoemulsification and implantation of foldable intraocular lens, some of whom under-went combined pars plana vitrectomy or trabeculectomy or silicone oil removal. Theperiod of follow-up was from 3 months to 17 months.Results: There is slight reaction postoperatively in all cases. The postoperative uncorrectedvisual acuites was from 0. 05 to 1.2, patient with 0.6 or above acuity were 70.98%. Aneodymium: YAG capsulotomy was required in 5 eyes. Posterior capsule ruptured in 1eyes, and a PMMA intraocular lens was implanted in ciliary sulcus. In one eye, a lenswas removed because of recurrence of retina detachment.Conclusions: The application of foldable intraocular lens in multiple types of cataract issafe, and there is a slight postoperative reaction. less complications , and fast visualacuity recovery.

  16. 超声乳化白内障吸除联合人工晶状体植入术后眼前节相干光断层扫描观察%Slit lamp optical coherence tomography study of anterior segment changes after phacoemulsification and foldable intraocular lens implantation

    Institute of Scientific and Technical Information of China (English)

    晏丕松; 张振平; 林浩添; 吴文捷; 柏凌

    2009-01-01

    目的 应用裂隙灯显微镜眼前节相干光断层扫描(OCT)观察超声乳化白内障吸除联合人工晶状体(IOL)植入术后眼前节组织的变化情况,探讨手术对眼前节结构的影响.方法 前瞻性系列病例研究.使用海德堡公司裂隙灯显微镜眼前节OCT观察40例(44只眼)行超声乳化白内障吸除联合IOL植入术患者术前和术后1 d、1周、2周及1个月的眼前节组织变化情况.对所测量的数据进行重复测量设计资料的方差分析,用LSD法进行两两比较.结果 中央及切口处角膜在术后第1天全部患者均明显增厚(与术前相比增厚分别为99.59μm,234.57μm;P=0.490),中央角膜厚度至术后1个月可恢复术前水平,而切口处角膜厚度还较术前厚约19.25μm(P=0.001);前房深度(ACD)和各项反映前房角宽度的指标(AOD500、AOD750、TISA500、TISA750)在术后各观察时间点,均较术前明显加深和加宽(均P0.05).结论 裂隙灯显微镜眼前节OCT可客观、定量评价白内障手术对眼前节形态特征的影响.%Objective To investigate quantitative changes of the anterior segment configuration after clear corneal incision phacoemulsification and foldable intraocular lens (IOL) implantation with slit-lamp-adapted optical coherence tomography (SL-OCT). Methods In prospective consecutive case series, clear corneal incision phacoemulsification and foldable intraocular lens implantation were performed in 44 eyes of 40 patients. The changes of the anterior segment configuration were performed by SL-OCT before and 1 day, 1 week, 2 weeks and 1 month after surgery. SPSS 16.0 software was used to analyze statistical difference. Results For all patients, the central corneal thickness (CCT) and the incisional corneal thickness (ICT) increased significantly 1 day after surgery ( CCT increased 99. 59 μm, ICT increased 234. 57 μm;P = O. 490). At 1 month, the CCT almost had returned to baseline, but the ICT had been ticker about 19. 25 μm than

  17. Radiocarbon dating of the human eye lens crystallines reveal proteins without carbon turnover throughout life

    DEFF Research Database (Denmark)

    Lynnerup, Niels; Kjeldsen, Henrik; Heegaard, Steffen;

    2008-01-01

    BACKGROUND: Lens crystallines are special proteins in the eye lens. Because the epithelial basement membrane (lens capsule) completely encloses the lens, desquamation of aging cells is impossible, and due to the complete absence of blood vessels or transport of metabolites in this area, there is ......BACKGROUND: Lens crystallines are special proteins in the eye lens. Because the epithelial basement membrane (lens capsule) completely encloses the lens, desquamation of aging cells is impossible, and due to the complete absence of blood vessels or transport of metabolites in this area...... dating is made possible by comparing the (14)C content of the lens crystallines to the so-called bomb pulse, i.e. a plot of the atmospheric (14)C content since the Second World War, when there was a significant increase due to nuclear-bomb testing. Since the change in concentration is significant even...... turnover rates and degree of substitution (for example for brain cell DNA). Potential targets may be nervous tissues in terms of senile or pre-senile degradation, as well as other highly specialised structures of the eyes. The precision with which the year of birth may be calculated points to forensic uses...

  18. Linguatula serrata in the anterior chamber of the eye

    Directory of Open Access Journals (Sweden)

    Muna Bhende

    2014-01-01

    Full Text Available We report a case of intraocular Linguatula in healthy young female who presented with a history of trivial trauma, dislocated lens, inflammation and secondary glaucoma. A mobile worm was seen in the anterior chamber. Pars plana lensectomy and vitrectomy was planned to remove both the cataractous lens and the parasite during which the worm disappeared from view but was later recovered from the cassette fluid. It was identified as the nymphal form of Linguatula serrata (tongue worm.

  19. Foreign Body Embedded in Anterior Chamber Angle

    OpenAIRE

    Shmuel Graffi; Beatrice Tiosano; Ran Ben Cnaan; Jonathan Bahir; Modi Naftali

    2012-01-01

    Introduction. We present a case of a metallic foreign body embedded in the anterior chamber angle. After standing in close proximity to a construction worker breaking a tile, a 26-year-old woman using soft contact lens for the correction of mild myopia presented to emergency department for evaluation of a foreign body sensation of her right eye. Methods and Results. Diagnosis was confirmed by gonioscopic examination and a noncontrast CT scan of head and orbits. The foreign body was removed by...

  20. Patient acceptability of the Tecnis® multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Sood P

    2011-03-01

    Full Text Available Priyanka Sood1, Maria A Woodward21Emory Eye Center, Atlanta, GA, USA; 2Kellogg Eye Center, Ann Arbor, MI, USAAbstract: Cataract surgery has evolved. The goal of the surgeon includes both restoration of vision and refinement of vision. Patients' desire for spectacle independence has driven the market for presbyopia-correcting cataract surgery and development of novel intraocular lens (IOL designs. The Tecnis® Multifocal Intraocular Lens incorporates an aspheric, modified anterior prolate IOL with a diffractive multifocal lens design. The design aims to minimize spherical aberration and improve range of focus. The purpose of this review is to assess patient acceptability of the Tecnis® multifocal intraocular lens.Keywords: Tecnis®, intraocular lens, multifocal, presbyopia 

  1. Capsule endoscopy in celiac disease

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Video capsule endoscopy is an attractive and patient- friendly tool that provides high quality images of the small bowel. Obscure gastrointestinal bleeding is the primary and most evaluated indication to capsule endoscopy; however, indications are expanding and a small number of preliminary reports have been presented concerning the role of video capsule endoscopy in the diagnosis of celiac disease. The purpose of this review is to update the current knowledge and to hypothesize on future perspectives of the use of video capsule endoscopy in patients with celiac disease.

  2. Changes of Anterior Chamber Angle and Intraocular Pressure after Implantation of Intraocular Lens through Small Incision in a Non-phacoemulsification Way%小切口非超声乳化人工晶状体植入术后房角及眼压变化的相关性研究

    Institute of Scientific and Technical Information of China (English)

    刘玉青; 冀向宁; 李坤; 戴冬姝

    2012-01-01

    Objective To explore the correlation between the anterior chamber angle and intraocular pressure after the implantation of intraocular lens ( iol) through small incision in a non - phacoemulsification way. Methods Totally 110 senile cataract patients admitted to our hospital in 2010 underwent implantation of iol with superficial anaesthesia through small incision. Among whom we chose 101 senile cataract patients ( 104 eyes ) as the research subjects whose operation process was smooth and the posterior capsulars remained complete and iol successfully being implanted into capsular bag. Relevant parameters of anterior chamber including anterior open distance at 500μm ( AOD500 ), trabeculum - tunica coerulea included angle ( TIA ), anterior chamber depth ( ACD ) were measured by ultrasonic biomicroscope ( UBM ) preoperatively. Intraocular pressures were measured by Goldmann ophthalmotonometer. All these parameters were re - measured by the same technician 2 weeks, 1 month, and 3 months postoperatively. Morphouses of the anterior chambers were recorded preoperatively and re - recorded 1 month postopera-tively through microgonioscope. Results Compared with the normal eyes, the intraocular pressure showed significant difference in these diseased eyes before surgery ( P < 0. 05 ). ACD, AOD 500, TIA, and intraocular pressure before surgery were also significantly different from thoese 2 weeks, 1 month, and 3 months after surgery ( P < 0. 05 ). In addition, AOD 500 and TIA had a negative correlation with intraocular pressure. Conclusion Small incision of non - phacoemulsification and intraocular lens ( iol) implantation might result in an enlargement of ACD and width of anterior chamber and a significant decrease of intraocular pressure. AOD500 and TIA are important factors that influence the intraocular pressure in the elderly.%目的 研究小切口非超声乳化人工晶状体植入术后前房角宽度及眼压变化的相关性.方法 选取2010年在我院就

  3. Quantitative observation on changes of anterior segment by ultrasound biomicroscopy after posterior chamber phakic intraocular lens implantation%UBM量化观察有晶状体眼后房型人工晶状体植入术前后眼前节形态的变化

    Institute of Scientific and Technical Information of China (English)

    王瑞娜; 郑广瑛; 王松田; 王洁; 赵建国; 郭红亮; 赵丽君

    2011-01-01

    ObjectiveThe objective is to study the safety and effectiveness of implantation of posterior chamber phakic intraocular contact lens (ICL) by observing the changes in anterior segment using ultrasound biomicroscopy (UBM). Methods It was a perspective study. The study sampled 30 high myopia patients (30 eyes) who were treated with posterior chamber phakic ICL implant. Central anterior chamber depth (ACD), trabecular-iris angle (TIA), angle opening distance (AOD500), trabecular-ciliary processes distance (TCPD) and iris-ciliary processes distance (ICPD) were measured using UBM preoperatively,3 months and 1 year postoperatively. The distance from ICL to the central surface of lens and peripheral lens and intra-ocular pressure were measured postoperatively and examined using slit-lamp biomicroscope. Oneway ANOVA was used to analyze the distance between peripheral surface of ICL and the lens. One-way repeated measures ANOVA and Bonferroni were conducted. Results Preoperatively, 3 months and 1 year postoperatively, ACD were(3. 16 ± 0. 08 ) mm, ( 2. 76 ± 0. 13 ) mm, (2. 74 ± 0. 14) mm; AOD500 were (0.45 + 0.04) mm, (0.41 ± 0.04) mm, (0.41 ±0.03) mm; TIA were (35.00 ±3. 24)°, (32.47 ±3.56) °, (32. 40 ± 3. 23 ) °, respectively. There were significant difference in TIA, ACD and AOD ( P <0. 05) between preoperative and postoperative data. There was no significant difference between the two postoperative periods tested. TCPD and ICPD showed no significant difference between various time points ( F =0. 49, F =0. 57 ; P > 0. 05 ). Conclusions The decrease in ACD depth and correction in TIA and AOD were the noticeable changes observed in morphological structure of the ocular anterior segment after the ICL treatment. The incidence of complication did not increase as the result of the minor changes in morph structure during the course of the study. However, the long-term effects would require further long-term observation.%目的 应用超声生物显微镜(UBM)对

  4. Technology needs for the development of the accommodative intraocular lens

    Science.gov (United States)

    Nishi, Okihiro

    2010-02-01

    Refilling the lens capsule while preserving capsular integrity offers the potential to restore ocular accommodation. There are two persisting problems in capsular bag refilling for possible clinical application: Leakage of the injectable material through the capsular opening and capsular opacification. Numerous attempts for solving these cardinal problems have not been proven to be clinically applicable. Recently, we developed a novel capsular bag refilling procedure using a novel accommodative intraocular lens that serves as an optic as well as a plug for sealing the capsular opening. The procedure and the results of monkey experiments will be presented.

  5. Radial head button holing: a cause of irreducible anterior radial head dislocation.

    Science.gov (United States)

    Shin, Su-Mi; Chai, Jee Won; You, Ja Yeon; Park, Jina; Bae, Kee Jeong

    2016-10-01

    "Buttonholing" of the radial head through the anterior joint capsule is a known cause of irreducible anterior radial head dislocation associated with Monteggia injuries in pediatric patients. To the best of our knowledge, no report has described an injury consisting of buttonholing of the radial head through the annular ligament and a simultaneous radial head fracture in an adolescent. In the present case, the radiographic findings were a radial head fracture with anterior dislocation and lack of the anterior fat pad sign. Magnetic resonance imaging (MRI) clearly demonstrated anterior dislocation of the fractured radial head through the torn annular ligament. The anterior joint capsule and proximal portion of the annular ligament were interposed between the radial head and capitellum, preventing closed reduction of the radial head. Familiarity with this condition and imaging findings will aid clinicians to make a proper diagnosis and fast decision to perform an open reduction. PMID:27502623

  6. Methods to determine the volume of infrapatellar fat pad as an indicator of anterior cruciate ligament tear

    OpenAIRE

    Cheruvu, Bharadwaj; Goswami, Tarun; Tsatalis, James; Laughlin, Richard

    2014-01-01

    Introduction: Anterior knee pain is a common problem which affects adolescents and young adults. The most common mechanism for anterior knee pain arises from combination of compression and shear forces across the patellofemoral joint. The structures that commonly cause anterior knee pain include medial and lateral retinaculum, the patellar subchondral bone, the anterior synovium, joint capsule, patellar tendon, and infrapatellar fat pad. It is important to develop methods to measure volume of...

  7. Changes of anterior segment after early implantation of posterior chamber phakic intraocular lens for correction of high myopia%ICL植入术治疗高度近视术后早期眼前节形态的变化

    Institute of Scientific and Technical Information of China (English)

    黎冬平; 刘磊; 李新宇; 栗静; 王虎杰; 杨硕

    2014-01-01

    目的:我们应用眼前节全景分析仪( Pentacam)测量有晶状体眼后房型人工晶状体( ICL )植入术手术前后前节形态指标,评价有晶状体眼后房型人工晶状体植入术的安全性及稳定性。  方法:选取行有晶状体眼后房型人工晶状体植入术治疗的高度近视患者48例90眼,术后随访6mo。 Pentacam眼前节全景分析仪测量各时间点的中央前房深度( ACD)、3∶00位前房角( ICA)、角膜像差( CA)、角膜曲率( K)和角膜厚度(CCT)等指标。使用SPSS 19.0统计软件,描述术前术后各指标的分布特征,采用配对t检验对各指标进行手术前后的差异性比较。  结果:所有观察指标各时间点均呈正态分布。 ACD、3∶00位ICA较术前降低( P<0.05)。 CA中,总像差( CTA )及低阶像差( CLOA)较术前无统计差异( P>0.05),高阶像差(CHOA)则较术前有所增加(P<0.05);K略有减小(P<0.05)。 CCT较术前比较均无统计学差异( P>0.05)。对于术后有统计学意义变化的指标,均在术后1 mo时即达到稳定状态。  结论:应用眼前节全景分析仪( Pentacam )观察有晶状体眼后房型人工晶状体植入术眼前节形态的变化主要有ICA变窄, ACD变小, CHOA增加, K减小,尚在安全范围内,6 mo随访中各值均保持稳定,未出现并发症,但远期效果需进一步随访观察。%AIM:To evaluate safety and stability of ICL implantation treatment of high myopia through the observation of anterior segment parameters such as ACD and ICA over time pre-and post-operation changes by Pentacam. METHODS:According to the proposed inclusion criteria, 90 eyes (48 patients) with high myopia who accepted ICL implantation treatment were selected.The mean follow-ups are 6 months.Anterior segment parameters such as ACD, ICA ( 3'clock ) , corneal aberration ( CA ) , K-value and CCT were

  8. Apoptosis in the lens anlage of the heritable lens aplastic mouse (lap mouse).

    Science.gov (United States)

    Aso, S; Tashiro, M; Baba, R; Sawaki, M; Noda, S; Fujita, M

    1998-08-01

    Adult homozygous lap mice show various eye abnormalities, such as aphakia, retinal disorganization, and dysplasia of the cornea and anterior chamber. In the fetal eye of a homozygous lap mouse, the lens placode seems to develop normally. However, the lens vesicle progresses abnormally to form a mass of cells without a cavity, and the mass vanishes soon afterward. We examined cell death in the lens anlage of this mutant. The lens anlagen of homozygous lap and normal mice from days 10 to 12 of gestation were observed by light microscopy after DNA end-labeling by immunohistochemistry and by transmission electron microscopy. By light microscopy, a slight frequency of cell death was detected in the lens anlage encircling the surface ectoderm and in the anlage or in the anlage of both homozygous lap mice and normal mice at day 10 of gestation. Cell death was seen in the lens anlage encircling the surface ectoderm in the normal mouse and sporadically in the anlage of the homozygous lap mouse at day 10.5 of gestation. Cell death was visible at the area of the lens vesicle attached to the surface ectoderm and encircling the surrounding surface ectoderm in the normal mouse, and in the lens anlage encircling the surface ectoderm and the apex areas of the lens anlage in the homozygous lap mouse at day 11 of gestation. At day 12 of gestation, almost no cell death was observed in the lens anlage of the normal mouse. However, extensive areas of cell death were still seen in the lens anlage at its apex, at the inner region, and encircling the surface ectoderm in the homozygous lap mouse. Electron microscopic observation showed that the dead cells observed in the lens anlagen by light microscopy in normal and lap mice are the result of apoptosis. In lap mice, cells with cytoplasmic condensation were observed mainly at days 10 and 10.5 of gestation. Many apoptotic bodies which had been phagocytosed by adjacent cells were seen predominantly at day 11 of gestation. At day 12 of

  9. Optimal Design of Capsule Transporting Pipeline carrying Spherical Capsules

    Science.gov (United States)

    Asim, Taimoor; Mishra, Rakesh; Ubbi, Kuldip

    2012-05-01

    A capsule pipeline transports material or cargo in capsules propelled by fluid flowing through a pipeline. The cargo may either be contained in capsules (such as wheat enclosed inside sealed cylindrical containers), or may itself be the capsules (such as coal compressed into the shape of a cylinder or sphere). As the concept of capsule transportation is relatively new, the capsule pipelines need to be designed optimally for commercial viability. An optimal design of such a pipeline would have minimum pressure drop due to the presence of the solid medium in the pipeline, which corresponds to minimum head loss and hence minimum pumping power required to drive the capsules and the transporting fluid. The total cost for the manufacturing and maintenance of such pipelines is yet another important variable that needs to be considered for the widespread commercial acceptance of capsule transporting pipelines. To address this, the optimisation technique presented here is based on the least-cost principle. Pressure drop relationships have been incorporated to calculate the pumping requirements for the system. The maintenance and manufacturing costs have been computed separately to analyse their effects on the optimisation process. A design example has been included to show the usage of the model presented. The results indicate that for a specific throughput, there exists an optimum diameter of the pipeline for which the total cost for the piping system is at its minimum.

  10. LensClean revisited

    CERN Document Server

    Wucknitz, O

    2004-01-01

    We discuss the LensClean algorithm which for a given gravitational lens model fits a source brightness distribution to interferometric radio data in a similar way as standard Clean does in the unlensed case. The lens model parameters can then be varied in order to minimize the residuals and determine the best model for the lens mass distribution. Our variant of this method is improved in order to be useful and stable even for high dynamic range systems with nearly degenerated lens model parameters. Our test case B0218+357 is dominated by two bright images but the information needed to constrain the unknown parameters is provided only by the relatively smooth and weak Einstein ring. The new variant of LensClean is able to fit lens models even in this difficult case. In order to allow the use of general mass models with LensClean, we develop the new method LenTil which inverts the lens equation much more reliably than any other method. This high reliability is essential for the use as part of LensClean. Finally...

  11. Magnetism in metal-organic capsules

    Energy Technology Data Exchange (ETDEWEB)

    Atwood, Jerry L.; Brechin, Euan K; Dalgarno, Scott J.; Inglis, Ross; Jones, Leigh F.; Mossine, Andrew; Paterson, Martin J.; Power, Nicholas P.; Teat, Simon J.

    2010-01-07

    Nickel and cobalt seamed metal-organic capsules have been isolated and studied using structural, magnetic and computational approaches. Antiferromagnetic exchange in the Ni capsule results from coordination environments enforced by the capsule framework.

  12. Anterior chamber flare after trabeculectomy and after phacoemulsification

    OpenAIRE

    Siriwardena, D; Kotecha, A; Minassian, D; Dart, J.; KHAW, P.

    2000-01-01

    AIMS—To evaluate and compare prospectively the anterior chamber inflammatory response after phacoemulsification cataract surgery and after trabeculectomy with peripheral iridectomy.
METHODS—Anterior chamber inflammation was measured using the Kowa FM-500 laser flare meter in 131 patients undergoing trabeculectomy and 148 patients undergoing phacoemulsification cataract extraction with intraocular lens implantation. Flare was measured before surgery and on each postoperative visit up to 12 mon...

  13. Quantitative Analysis of Lens Nuclear Density Using Optical Coherence Tomography (OCT) with a Liquid Optics Interface: Correlation between OCT Images and LOCS III Grading.

    Science.gov (United States)

    Kim, You Na; Park, Jin Hyoung; Tchah, Hungwon

    2016-01-01

    Purpose. To quantify whole lens and nuclear lens densities using anterior-segment optical coherence tomography (OCT) with a liquid optics interface and evaluate their correlation with Lens Opacities Classification System III (LOCS III) lens grading and corrected distance visual acuity (BCVA). Methods. OCT images of the whole lens and lens nucleus of eyes with age-related nuclear cataract were analyzed using ImageJ software. The lens grade and nuclear density were represented in pixel intensity units (PIU) and correlations between PIU, BCVA, and LOCS III were assessed. Results. Forty-seven eyes were analyzed. The mean whole lens and lens nuclear densities were 26.99 ± 5.23 and 19.43 ± 6.15 PIU, respectively. A positive linear correlation was observed between lens opacities (R (2) = 0.187, p optics interface is a potential quantitative method for lens grading and can aid in monitoring and managing age-related cataracts. PMID:27651952

  14. Wireless capsule endo bronchoscopy

    Directory of Open Access Journals (Sweden)

    Baratz DM

    2014-03-01

    Full Text Available No abstract available. Article truncated at 150 words. Case Presentation History of Present Illness A 67 year-old man presents 10 days after swallowing a capsule endoscopy camera that was never retrieved. The wireless capsule was swallowed asymptomatically for evaluation of heme positive stools after negative upper and lower endoscopies. Patient noted that the evening after swallowing the camera he developed mild shortness of breath and cough. The cough and shortness of breath were persistent and worsened while lying down and when moving positions. He denied prior issues with swallowing or aspiration. Review of Systems Negative other than what is noted above. PMH, SH, and FH Past medical history: coronary artery disease, peripheral vascular disease, hyperlipidemia Surgical history: femoral-popliteal bypass, previous shoulder and back surgery Social history: 1 pack/day of cigarettes for 50 years, prior alcohol usage but not current, no illicit drugs Family history: no pulmonary diseases Physical Exam Vital signs: temperature 36.7º C, heart rate 86 beats per minute ...

  15. CORRECTION OF HIGH MYOPIA WITH THE WORST MYOPIA CLAW INTRAOCULAR-LENS

    NARCIS (Netherlands)

    LANDESZ, M; WORST, JGF; SIERTSEMA, JV; VANRIJ, G

    1995-01-01

    BACKGROUND: Phakic anterior chamber lenses is one of the modalities used to correct high myopia, We report the initial results of our prospective study on the Worst myopia claw intraocular lens (IOL) that is fixated to the anterior iris, METHODS: We studied 35 eyes in 18 patients with a preoperative

  16. REFRACTIVE NEUTRON LENS

    OpenAIRE

    Petrov, P. V.; Kolchevsky, N.N.

    2013-01-01

    Compound concave refractive lenses are used for focusing neutron beam. Investigations of spectral and focusing properties of a refractive neutron lens are presented. Resolution of the imaging system on the base of refractive neutron lenses depends on material properties and parameters of neutron source. Model of refractive neutron lens are proposed. Results of calculation diffraction resolution and focal depth of refractive neutron lens are discussed.

  17. Len Yi Part 2

    OpenAIRE

    Bsod nams rgyal mtshan

    2011-01-01

    INTRODUCTION: Sonan Jetsun (Bsod nams rgyal mtshan) filmed this material 12-22 January 2008 in Len yi (Lianyi) Village, Sgong po (Gongbo) Township, Sde rong (Derong) County, Dkar mdzes (Ganzi) Tibetan Autonomous Prefecture, Si khron (Sichuan) Province, PR China. The film features the Tibetan New Year, Bkra shis Temple, and ordinary people's lives in Len yi Village. Sonan Jetsun also edited the material and plans to give it to Len yi villagers on DVD/ VCD. LOCATION: Lianyi Village is 200 k...

  18. Quantitative measurements in capsule endoscopy.

    Science.gov (United States)

    Keuchel, M; Kurniawan, N; Baltes, P; Bandorski, D; Koulaouzidis, A

    2015-10-01

    This review summarizes several approaches for quantitative measurement in capsule endoscopy. Video capsule endoscopy (VCE) typically provides wireless imaging of small bowel. Currently, a variety of quantitative measurements are implemented in commercially available hardware/software. The majority is proprietary and hence undisclosed algorithms. Measurement of amount of luminal contamination allows calculating scores from whole VCE studies. Other scores express the severity of small bowel lesions in Crohn׳s disease or the degree of villous atrophy in celiac disease. Image processing with numerous algorithms of textural and color feature extraction is further in the research focuses for automated image analysis. These tools aim to select single images with relevant lesions as blood, ulcers, polyps and tumors or to omit images showing only luminal contamination. Analysis of motility pattern, size measurement and determination of capsule localization are additional topics. Non-visual wireless capsules transmitting data acquired with specific sensors from the gastrointestinal (GI) tract are available for clinical routine. This includes pH measurement in the esophagus for the diagnosis of acid gastro-esophageal reflux. A wireless motility capsule provides GI motility analysis on the basis of pH, pressure, and temperature measurement. Electromagnetically tracking of another motility capsule allows visualization of motility. However, measurement of substances by GI capsules is of great interest but still at an early stage of development. PMID:26299419

  19. Spatial pattern of cell geometry and cell-division orientation in zebrafish lens epithelium

    Directory of Open Access Journals (Sweden)

    Toshiaki Mochizuki

    2014-09-01

    Full Text Available Cell proliferation is a key regulator of tissue morphogenesis. We examined cell proliferation and cell division in zebrafish lens epithelium by visualizing cell-cycle phases and nuclear positions, using fluorescent-labeled geminin and histone proteins. Proliferation was low in the anterior region of lens epithelium and higher in the marginal zone anterior to the equator, suggesting that the proliferation zone, called the germinative zone, is formed in zebrafish lens. Interestingly, cell-division orientation was biased longitudinally in the anterior region, shifted from longitudinal to circumferential along the anterior–posterior axis of lens sphere, and was biased circumferentially in the peripheral region. These data suggest that cell-division orientation is spatially regulated in zebrafish lens epithelium. The Hertwig rule indicates that cells tend to divide along their long axes. Orientation of long axes and cell division were biased similarly in zebrafish lens epithelium, suggesting that cell geometry correlates with cell-division orientation. A cell adhesion molecule, E-cadherin, is expressed in lens epithelium. In a zebrafish e-cadherin mutant, the long axes and cell-division orientation were shifted more longitudinally. These data suggest that E-cadherin is required for the spatial pattern of cell geometry and cell-division orientation in zebrafish lens epithelium.

  20. Lens auto-centering

    Science.gov (United States)

    Lamontagne, Frédéric; Desnoyers, Nichola; Doucet, Michel; Côté, Patrice; Gauvin, Jonny; Anctil, Geneviève; Tremblay, Mathieu

    2015-09-01

    In a typical optical system, optical elements usually need to be precisely positioned and aligned to perform the correct optical function. This positioning and alignment involves securing the optical element in a holder or mount. Proper centering of an optical element with respect to the holder is a delicate operation that generally requires tight manufacturing tolerances or active alignment, resulting in costly optical assemblies. To optimize optical performance and minimize manufacturing cost, there is a need for a lens mounting method that could relax manufacturing tolerance, reduce assembly time and provide high centering accuracy. This paper presents a patent pending lens mounting method developed at INO that can be compared to the drop-in technique for its simplicity while providing the level of accuracy close to that achievable with techniques using a centering machine (usually innovative auto-centering method is based on the use of geometrical relationship between the lens diameter, the lens radius of curvature and the thread angle of the retaining ring. The autocentering principle and centering test results performed on real optical assemblies are presented. In addition to the low assembly time, high centering accuracy, and environmental robustness, the INO auto-centering method has the advantage of relaxing lens and barrel bore diameter tolerances as well as lens wedge tolerances. The use of this novel lens mounting method significantly reduces manufacturing and assembly costs for high performance optical systems. Large volume productions would especially benefit from this advancement in precision lens mounting, potentially providing a drastic cost reduction.

  1. Ophthalmohelioses and peripheral light focusing by the anterior eye

    Science.gov (United States)

    Coroneo, Minas T.

    1994-07-01

    A coincidence of the locations of foci of scattered light in the anterior eye with the usual locations of common sun-related eye conditions has been observed. These phenomena may explain the pathogenesis of pterygium and the initial location of certain cortical lens opacities and eyelid malignancies. Human and bovine eyes were used to demonstrate that the anterior eye acts as a side-on lens system. Light incident at the temporal limbus can be concentrated at the nasal limbus or beyond or at the nasal crystalline lens equator. The main pathways of light are transcameral and this is demonstrated by the use of baffles. Although this phenomenon is obvious with visible light, focusing of light at 308nm can be demonstrated. Computer-assisted optical ray tracing in a standard human anterior segment model showed that the peak intensity at the distal limbus is approximately twenty times that of the incident light intensity. The degree of limbal focusing is determined by corneal shape and anterior chamber depth. Such light focusing may be particularly injurious to corneal and lenticular epithelial stem cells. These observations provide circumstantial evidence that peripheral refraction phenomena are involved in the pathogenesis of the anterior ophthalmohelioses. Adequate lateral protection of the eye from increasing ultraviolet insolation may be prudent.

  2. Adhesive capsulitis: a case report

    OpenAIRE

    Kazemi, Mohsen

    2000-01-01

    Adhesive capsulitis or frozen shoulder is an uncommon entity in athletes. However, it is a common cause of shoulder pain and disability in the general population. Although it is a self limiting ailment, its rather long, restrictive and painful course forces the affected person to seek treatment. Conservative management remains the mainstay treatment of adhesive capsulitis. This includes chiropractic manipulation of the shoulder, therapeutic modalities, mobilization, exercise, soft tissue ther...

  3. Superlensing Microscope Objective Lens

    CERN Document Server

    Yan, Bing; Parker, Alan; Lai, Yukun; Thomas, John; Yue, Liyang; Monks, James

    2016-01-01

    Conventional microscope objective lenses are diffraction limited, which means that they cannot resolve features smaller than half the illumination wavelength. Under white light illumination, such resolution limit is about 250-300 nm for an ordinary microscope. In this paper, we demonstrate a new superlensing objective lens which has a resolution of about 100 nm, offering at least two times resolution improvement over conventional objectives in resolution. This is achieved by integrating a conventional microscope objective lens with a superlensing microsphere lens using a 3D printed lens adaptor. The new objective lens was used for label-free super-resolution imaging of 100 nm-sized engineering and biological samples, including a Blu-ray disc sample, semiconductor chip and adenoviruses. Our work creates a solid base for developing a commercially-viable superlens prototype, which has potential to transform the field of optical microscopy and imaging.

  4. Histological observation of complete closure of anterior capsulotomy in 2 cases.

    Science.gov (United States)

    Tanaka, Sai-Ichi; Saika, Shizuya; Tamura, Manabu; Ohnishi, Yoshitaka

    2004-06-01

    We report the histological finding of complete closure of the anterior capsulotomy window in 2 cases. The cases were successfully treated with surgery after neodymium:YAG laser anterior capsulotomy failed. Histology and immunohistochemistry were performed to determine the pathogenesis. Histology revealed the presence of elongated, fibroblast-like lens epithelial cells in association with extracellular matrix accumulation, which were positive for collagen types, fibronectin, and osteopontin. The cells were labeled with anti-alpha-smooth muscle actin antibody. The finding indicates that phenotypic modulation in lens epithelial cell to contractile cell type and accumulation of matrix are involved in closure of the anterior capsulotomy window.

  5. Anterior dislocation of an empty capsular bag in a pseudophakic eye: A rare case report

    Directory of Open Access Journals (Sweden)

    Hyung Bin Hwang

    2015-01-01

    Full Text Available Spontaneous intraocular lens (IOL dislocation is uncommon in the absence of any ocular areas with zonular weakness or trauma. There have been no reports of spontaneous capsular bag dislocation into the anterior chamber without an IOL. We report a rare, interesting case of spontaneous capsular bag anterior dislocation, without an IOL, into the anterior chamber with no history of genetic disease, ocular trauma, or pseudoexfoliation that might predispose to a zonular abnormality.

  6. Deformability-based capsule sorting

    Science.gov (United States)

    Le Goff, Anne; Munier, Nadege; Maire, Pauline; Edwards-Levy, Florence; Salsac, Anne-Virginie

    2015-11-01

    Many microfluidic devices have been developed for cancer diagnosis applications, most of which relying on costly antibodies. Since some cancer cells display abnormal mechanical properties, new sorting tools based on mechanical sensing are of particular interest. We present a simple, passive pinched flow microfluidic system for capsule sorting. The device consists of a straight microchannel containing a cylindrical obstacle. Thanks to a flow-focusing module placed at the channel entrance, capsules arrive well-centered in the vicinity of the obstacle. Pure size-sorting can be achieved at low shear rate. When increasing the shear rate, capsules are deformed in the narrow space between the pillar and the wall. The softer the capsule, the more tightly it wraps around the obstacle. After the obstacle, streamlines diverge, allowing for the separation between soft capsules, that follow central streamlines, and stiff capsules, that drift away from the obstacle with a wider angle. This proves that we have developed a flexible multipurpose sorting microsystem based on a simple design.

  7. Pneumatic capsule pipeline system

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, J.; Partyka, J.; Rudd, L. [Laurentian Univ., School of Engineering, Sudbury, ON (Canada)

    2001-03-01

    With the rising cost of transporting ores and concentrates, alternatives to the traditional means of transportation by rail, trucks and hoists are being actively sought, as a means of reducing operating costs. Pneumatic encapsulated pipeline (PCP) transportation of raw, processed, or waste materials is being looked upon as a potentially viable alternative for material handling in the mining industry. There are several operating PCP systems in Europe and in Japan, although there are as yet no similar applications in North America. To evaluate the viability of pneumatic capsule pipeline systems, a 600 mm diameter, 70 m long pilot PCP plant, made of rigid fibreglass, was constructed at Laurentian University and several tests have already been conducted. It was found that any bulk material can be transported by PCP safely, with relatively small amounts of power, over long distances, and at a significantly reduced cost, while maintaining complete control. Both underground as well as surface applications appear to be viable. This paper concentrates on the results of experiments designed to test the energy requirements of a PCP system. Future studies should focus on exploring and improving the ability of PCP systems to transport vertically which would be a great advantage to hauling ore from underground mines to the surface. 3 refs., 2 tabs., 14 figs.

  8. Biomechanics of the Hip Capsule and Capsule Management Strategies in Hip Arthroscopy.

    Science.gov (United States)

    Nepple, Jeffrey J; Smith, Matthew V

    2015-12-01

    Recent advances in our understanding of the function of the hip capsule have clarified its importance to normal hip function and kinematics. The iliofemoral ligament is the primary stabilizing structure for controlling anterior translation and external rotation of the hip, and is violated by the arthroscopic interportal capsulotomy. Microinstability of the hip occurring after surgical trauma remains a poorly defined clinical entity. In certain at-risk populations, capsular repair should be considered as part of an arthroscopic hip procedure to achieve optimal outcomes and avoid iatrogenic instability (dislocation or microinstability). Despite a lack of conclusive evidence-based indications, we recommend capsular repair in the settings of borderline hip dysplasia (or dysplastic variants such as increased femoral anteversion), hip hypermobility, connective tissue disorders, and traumatic or atraumatic instability. With careful attention to arthroscopic capsular management, adequate exposure can be achieved and reproducibly allow for an effective capsular repair when indicated. PMID:26524549

  9. c-Myc regulates cell proliferation during lens development.

    Directory of Open Access Journals (Sweden)

    Gabriel R Cavalheiro

    Full Text Available Myc protooncogenes play important roles in the regulation of cell proliferation, growth, differentiation and survival during development. In various developing organs, c-myc has been shown to control the expression of cell cycle regulators and its misregulated expression is detected in many human tumors. Here, we show that c-myc gene (Myc is highly expressed in developing mouse lens. Targeted deletion of c-myc gene from head surface ectoderm dramatically impaired ocular organogenesis, resulting in severe microphtalmia, defective anterior segment development, formation of a lens stalk and/or aphakia. In particular, lenses lacking c-myc presented thinner epithelial cell layer and growth impairment that was detectable soon after its inactivation. Defective development of c-myc-null lens was not caused by increased cell death of lens progenitor cells. Instead, c-myc loss reduced cell proliferation, what was associated with an ectopic expression of Prox1 and p27(Kip1 proteins within epithelial cells. Interestingly, a sharp decrease in the expression of the forkhead box transcription factor Foxe3 was also observed following c-myc inactivation. These data represent the first description of the physiological roles played by a Myc family member in mouse lens development. Our findings support the conclusion that c-myc regulates the proliferation of lens epithelial cells in vivo and may, directly or indirectly, modulate the expression of classical cell cycle regulators in developing mouse lens.

  10. Hypoplastic basement membrane of the lens anlage in the inheritable lens aplastic mouse (lap mouse).

    Science.gov (United States)

    Aso, S; Baba, R; Noda, S; Ikuno, S; Fujita, M

    2000-04-01

    Adult homozygous lap mice show various eye abnormalities such as aphakia, retinal disorganization, and dysplasia of the cornea and anterior chamber. In the fetal eye of a homozygous lap mouse, the lens placode appears to develop normally. However, the lens vesicle develops abnormally to form a mass of cells without a cavity, and the mass vanishes soon afterward. Apoptotic cell death is associated with the disappearance of the lens anlage. We examined the basement membranes of the lens anlage of this mutant by immunohistochemical methods under light microscopy using antibodies against basement membrane components of the lens anlage, type IV collagen, fibronectin, laminin, heparan sulfate proteoglycan, and entactin and by transmission electron microscopy. Immunohistochemistry showed the distribution and intensity of antibody binding to the lens anlage to be almost the same for each these antibodies regardless of the stage of gestation or whether the anlagen were from normal BALB/c or lap mice. Thus, positive continuous reactions were observed around the exterior region of the lens anlage from day 10 of gestation for type IV collagen, fibronectin, laminin, heparan sulfate proteoglycan antibodies, and at least from day 11of gestation for entactin antibody. The basement membrane lamina densa of both normal and lap mice was shown by electron microscopy to be discontinuous at days 10 and 10.5 of gestation. However, by day 11 the lamina densa was continuous in the lens anlagen of normal mice but still discontinuous in the lap mice. By day 12 of gestation, the lamina densa had thickened markedly in normal mice, whereas in lap mice it remained discontinuous and its thinness indicated hypoplasia. These results indicate that, while all basement components examined are produced and deposited in the normal region of the lens anlage in the lap mouse, the basement membrane is, for some reason, imperfectly formed. The time at which hypoplasia of the basement membrane was observed

  11. Optimisation of a Horizontal Capsule Transporting Pipeline carrying Cylindrical Capsules

    Science.gov (United States)

    Asim, Taimoor; Mishra, Rakesh; Kollar, Laszlo; Ubbi, Kuldip

    2012-05-01

    Pipelines carrying fluids and slurries are quite common. The third-generation pipelines carrying spherical or cylindrical capsules (hollow containers) filled with minerals or other materials including hazardous liquids are rather a new concept. These pipelines need to be designed optimally for commercial viability. An optimal design of such a pipeline results in minimum pressure drop in the pipeline. This corresponds to minimum head loss and hence minimum pumping power required to drive the capsules and the transporting fluid. This study uses a rigorous approach to predict pumping cost based on Computational Fluid Dynamics (CFD) and hence optimize the design of the capsule transporting pipelines. Pressure drop relationship developed has been incorporated to calculate the pumping requirements for the system. Based on the least-cost principle, a methodology has been developed for the determination of the optimal diameter of cylindrical capsule carrying hydraulic pipeline. This procedure can be applied to obtain the optimal size of the capsule pipeline for minimum pumping and capital costs.

  12. Summary Report for Capsule Dry Storage Project

    Energy Technology Data Exchange (ETDEWEB)

    JOSEPHSON, W S

    2003-09-04

    There are 1.936 cesium (Cs) and strontium (Sr) capsules stored in pools at the Waste Encapsulation and Storage Facility (WESF). These capsules will be moved to dry storage on the Hanford Site as an interim measure to reduce risk. The Cs/Sr Capsule Dry Storage Project (CDSP) is conducted under the assumption the capsules will eventually be moved to the repository at Yucca Mountain, and the design criteria include requirements that will facilitate acceptance at the repository. The storage system must also permit retrieval of capsules in the event vitrification of the capsule contents is pursued. A cut away drawing of a typical cesium chloride (CsCI) capsule and the capsule property and geometry information are provided in Figure 1.1. Strontium fluoride (SrF{sub 2}) capsules are similar in design to CsCl capsules. Further details of capsule design, current state, and reference information are given later in this report and its references. Capsule production and life history is covered in WMP-16938, Capsule Characterization Report for Capsule Dry Storage Project, and is briefly summarized in Section 5.2 of this report.

  13. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A.; Foreman, L.R.

    1997-07-08

    This invention describes a method for fabricating an intraocular lens made from clear Teflon{trademark}, Mylar{trademark}, or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube. 13 figs.

  14. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, Mike A. (Albuquerque, NM); Foreman, Larry R. (Los Alamos, NM)

    1997-01-01

    This invention describes a method for fabricating an intraocular lens made rom clear Teflon.TM., Mylar.TM., or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube.

  15. Unitary lens semiconductor device

    Science.gov (United States)

    Lear, Kevin L.

    1997-01-01

    A unitary lens semiconductor device and method. The unitary lens semiconductor device is provided with at least one semiconductor layer having a composition varying in the growth direction for unitarily forming one or more lenses in the semiconductor layer. Unitary lens semiconductor devices may be formed as light-processing devices such as microlenses, and as light-active devices such as light-emitting diodes, photodetectors, resonant-cavity light-emitting diodes, vertical-cavity surface-emitting lasers, and resonant cavity photodetectors.

  16. In-the-bag decentration of an intraocular lens in a patient with a tendency to hypertrophic scarring

    Science.gov (United States)

    Joshi, Rajesh Subhash

    2016-01-01

    Summary We report a case of rapid anterior lens capsular contraction leading to decentration of a hydrophilic acrylic lens with stiff haptics (Rayner design). To our knowledge, this is the first report to investigate early capsular contraction with folding of the haptic over the optic in a patient with a tendency toward hypertrophic scar formation. PMID:27330480

  17. Contact Lens Risks

    Science.gov (United States)

    ... Health and Consumer Devices Consumer Products Contact Lenses Contact Lens Risks Share Tweet Linkedin Pin it More ... redness blurred vision swelling pain Serious Hazards of Contact Lenses Symptoms of eye irritation can indicate a ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Sep 10, 2015 Contact Lens Horror Stories: Poor Care Can Lead to Blindness Sep 09, 2015 How to Correct High Myopia Feb 27, 2015 More Eye Health News Pet Fish Fitted with Fake Eye in ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  1. Terahertz Artificial Dielectric Lens

    Science.gov (United States)

    Mendis, Rajind; Nagai, Masaya; Wang, Yiqiu; Karl, Nicholas; Mittleman, Daniel M.

    2016-03-01

    We have designed, fabricated, and experimentally characterized a lens for the THz regime based on artificial dielectrics. These are man-made media that mimic properties of naturally occurring dielectric media, or even manifest properties that cannot generally occur in nature. For example, the well-known dielectric property, the refractive index, which usually has a value greater than unity, can have a value less than unity in an artificial dielectric. For our lens, the artificial-dielectric medium is made up of a parallel stack of 100 μm thick metal plates that form an array of parallel-plate waveguides. The convergent lens has a plano-concave geometry, in contrast to conventional dielectric lenses. Our results demonstrate that this lens is capable of focusing a 2 cm diameter beam to a spot size of 4 mm, at the design frequency of 0.17 THz. The results further demonstrate that the overall power transmission of the lens can be better than certain conventional dielectric lenses commonly used in the THz regime. Intriguingly, we also observe that under certain conditions, the lens boundary demarcated by the discontinuous plate edges actually resembles a smooth continuous surface. These results highlight the importance of this artificial-dielectric technology for the development of future THz-wave devices.

  2. Triggered Release from Polymer Capsules

    Energy Technology Data Exchange (ETDEWEB)

    Esser-Kahn, Aaron P. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Odom, Susan A. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Sottos, Nancy R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Materials Science and Engineering; White, Scott R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Aerospace Engineering; Moore, Jeffrey S. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry

    2011-07-06

    Stimuli-responsive capsules are of interest in drug delivery, fragrance release, food preservation, and self-healing materials. Many methods are used to trigger the release of encapsulated contents. Here we highlight mechanisms for the controlled release of encapsulated cargo that utilize chemical reactions occurring in solid polymeric shell walls. Triggering mechanisms responsible for covalent bond cleavage that result in the release of capsule contents include chemical, biological, light, thermal, magnetic, and electrical stimuli. We present methods for encapsulation and release, triggering methods, and mechanisms and conclude with our opinions on interesting obstacles for chemically induced activation with relevance for controlled release.

  3. 有晶状体眼后房型人工晶状体植入术后前房角的变化及其相关因素%The change in anterior chamber angle and related factors in collamer lens implantation

    Institute of Scientific and Technical Information of China (English)

    朱浩斌; 贾琰; 周激波

    2014-01-01

    目的 研究高度近视眼植入有晶状体眼后房型人工晶状体(PPC-ICL)后前房角(ACA)的变化及其相关因素.方法 前瞻性研究.收集2013年3月至2014年4月在上海交通大学医学院附属第九人民医院行PPC-ICL植入手术的中高度近视患者26例(45眼).术后平均随访(4.3±3.2)个月.Pentacam测量术前及术后ACA、前房深度、角膜曲率、PPC-ICL拱高(vault).IOLMaster测量白到白距离和眼轴长度.同时记录术前及术后UCVA、等效球镜度及IOP.采用配对t检验、Wilcoxon符号秩和检验、Pearson相关、Spearman秩相关、多元回归分析进行数据分析.结果 3点方位术后ACA宽度为27.44°-±5.24°,与术前43.23°±5.72°比较,差异有统计学意义(Z=-5.841,P<0.01).3点方位ACA宽度的变化量与PPC-ICL拱高、同方位术前ACA宽度呈正相关(r=0.556、0.530,P<0.01),术后ACA宽度与拱高、术前ACA宽度回归方程为ACA术后=4.860-0.009 vault±0.621 ACA术前(F=20.032,P<0.01).9点方位ACA宽度术后为26.82°±4.73°,与术前42.40°±5.81°比较,差异有统计学意义(t=20.890,P<0.01);9点方位ACA宽度的变化量与PPC-ICL拱高、同方位术前ACA宽度呈正相关(r=0.581、0.626,P<0.01),术后ACA宽度和拱高、术前ACA宽度回归方程为ACA术后=5.767-0.008 vault±0.586 ACA术前(F=24.775,P<0.01).结论 PPC-ICL植入术后水平方向ACA宽度显著变小,变化量和术前ACA宽度、拱高均呈正相关.%Objective To investigate the change in the anterior chamber angle and to analyze its related factors of phakic posterior chamber implantable collamer lens (PPC-ICL) implantation.Methods Twenty-six moderate and high myopic patients (45 eyes) who received PPC-ICL implants from March 2013 to April 2014 were included in this prospective study.The mean follow-up time was 4.3±3.2 months.Anterior chamber angle (ACA),anterior chamber depth (ACD),corneal curvature,and vault were measured with a Pentacam preoperatively and

  4. CONGENITAL ANTERIOR TIBIOFEMURAL SUBLUXATION

    Directory of Open Access Journals (Sweden)

    A. Shahla

    2008-06-01

    Full Text Available Congenital anterior tibiofemoral subluxation is an extremely rare disorder. All reported cases accompanied by other abnormalities and syndromes. A 16-year-old high school girl referred to us with bilateral anterior tibiofemoral subluxation as the knees were extended and reduced at more than 30 degrees flexion. Deformities were due to tightness of the iliotibial band and biceps femuris muscles and corrected by surgical release. Associated disorders included bilateral anterior shoulders dislocation, short metacarpals and metatarsals, and right calcaneuvalgus deformity.

  5. Bilateral anterior shoulder dislocation

    OpenAIRE

    Meena, Sanjay; Saini, Pramod; Singh, Vivek; Kumar, Ramakant; Trikha, Vivek

    2013-01-01

    Shoulder dislocations are the most common major joint dislocations encountered in the emergency departments. Bilateral shoulder dislocations are rare and of these, bilateral posterior shoulder dislocations are more prevalent than bilateral anterior shoulder dislocations. Bilateral anterior shoulder dislocation is very rare. We present a case of 24-year-old male who sustained bilateral anterior shoulder dislocation following minor trauma, with associated greater tuberosity fracture on one side...

  6. Internal capsule stroke in the common marmoset.

    Science.gov (United States)

    Puentes, S; Kaido, T; Hanakawa, T; Ichinohe, N; Otsuki, T; Seki, K

    2015-01-22

    White matter (WM) impairment and motor deficit after stroke are directly related. However, WM injury mechanisms and their relation to motor disturbances are still poorly understood. In humans, the anterior choroidal artery (AChA) irrigates the internal capsule (IC), and stroke to this region can induce isolated motor impairment. The goal of this study was to analyze whether AChA occlusion can injure the IC in the marmoset monkey. The vascular distribution of the marmoset brain was examined by colored latex perfusion and revealed high resemblance to the human brain anatomy. Next, a new approach to electrocoagulate the AChA was developed and chronic experiments showed infarction compromising the IC on magnetic resonance imaging (MRI) scanning (day 4) and histology (day 11). Behavioral analysis was performed using a neurologic score previously developed and our own scoring method. Marmosets showed a decreased score that was still evident at day 10 after AChA electrocoagulation. We developed a new approach able to induce damage to the marmoset IC that may be useful for the detailed study of WM impairment and behavioral changes after stroke in the nonhuman primate. PMID:25453768

  7. Photon Production Within Storage Capsules

    CERN Document Server

    Rittmann, P D

    2003-01-01

    This report provides tables and electronic worksheets that list the photon production rate within SrF2 and CsC1 storage capsules, particularly the continuous spectrum of bremsstrahlung photons from the slowing down of the emitted electrons (BREMCALC).

  8. Capsule endoscopy in pediatric patients

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Wireless capsule endoscope (WCE) for the investigation of the small bowel is an approved technique both in adults and children (more than 10 years old). The present review provides data on the indications, diagnostic yield, adverse events and limitations of the WCE technique in children and tries to predict the future of WCE usage in this population of patients.

  9. Bilateral spontaneous dislocation of posterior chamber intraocular lens in a patient with gyrate atrophy

    Directory of Open Access Journals (Sweden)

    Michael Kinori

    2012-01-01

    Full Text Available We report a patient with gyrate atrophy, a rare metabolic disease, who had bilateral late spontaneous posterior dislocation of in-the-bag posterior chamber intraocular lens (PCIOL. He underwent pars plana vitrectomy, PCIOL retrieval and anterior chamber intraocular lens implantation in both eyes. This report may imply that patients with gyrate atrophy are at risk for spontaneous dislocation of intraocular lenses.

  10. [Keratouveitis and lens opacity caused by butterfly hair].

    Science.gov (United States)

    Domngang Noche, C; Kengmogne, B; Bella, A L

    2012-01-01

    Butterfly hair is known to cause eye injury. In Africa, incriminated butterflies are Hylesia (spp). We report a case of a sub-epithelial keratitis associated with anterior uveitis following a trauma by a butterfly that was complicated by late lens opacity due to butterfly hair. Ocular lesions caused by butterfly hair are rare, but require an urgent management to prevent late and severe complications due to intraocular migration of the hairs. PMID:22978182

  11. Ultrasound Biomicroscopy of Iris-claw Phakic Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Ayong Yu; Zhende Lin; Xiaoyu Cai; Xiuqi Chen; Shuke Luo; Yonghua Li

    2006-01-01

    Purpose: To study in situ the intraocular position of iris-claw phakic intraocular lens (ICPIOL) in myopic eyes using ultrasound biomicroscopy (UBM).Methods: UBM echograms of the anterior segment were taken preoperatively and 62to 115 days postoperatively in 6 eyes implanted with the Verisys ICPIOL (AMO). The echograms were assessed for the effect of the ICPIOL on iris tissue.Results: The preoperative distance between the corneal endothelium and the lens ranged from 2.96 to 3.09 mm, and the postoperative distance between the ICPIOL and the corneal endothelium, from 1.86 to 2.03 mm. The distance between the lens and the posterior surface of the ICPIOL ranged from 0.61 to 0.76 mm. The distance between the superior, inferior optic edge and the iris ranged from 0.49 to 1.00 mm,0.21 to 0.51 mm respectively. The shortest distance between the ICPIOL haptics and the angle of anterior chamber ranged from 1.25 to 1.65 mm. The indentation of iris tissue by the ICPIOL haptics without pigmentary dispersion and distortion of posterior curvature of iris was observed.Conclusion: Adequate space is maintained between the Verisyse myopic ICPIOL and the corneal endothelium, angle, and crystalline lens. Haptic indentation of the iris without pigment erosion and distortion of iris curvature is noted. The ICPIOL implanted in phakic eyes is a safe alternative for treatment of high myopia.

  12. Intraocular lens exchange-removing the optic intact

    Science.gov (United States)

    Lee, Matthew Hao; Webster, Diane Lesley

    2016-01-01

    Current practice for intraocular lens (IOL) exchange is to cut the optic of the posterior chamber intraocular lens (PCIOL) prior to removing it. Great care must be taken during this maneuver to avoid a posterior capsular tear. Removing the haptics from the fibrosed capsule can also be hazardous, as it may result in zonular stress and dehiscence. A technique is described for performing foldable (one-piece acrylic) IOL removal without cutting the optic. Careful visco-dissection of the haptics with a low viscosity ophthalmic viscosurgical device (OVD) in the fibrosed peripheral capsular tunnel avoids zonular or capsular stress. Internal wound enlargement permits foldable IOL removal in one piece, whilst preserving a self-sealing sutureless corneal wound. This technique may enhance the safety and efficacy of foldable IOL exchange. PMID:27366699

  13. Intraocular lens exchange-removing the optic intact.

    Science.gov (United States)

    Lee, Matthew Hao; Webster, Diane Lesley

    2016-01-01

    Current practice for intraocular lens (IOL) exchange is to cut the optic of the posterior chamber intraocular lens (PCIOL) prior to removing it. Great care must be taken during this maneuver to avoid a posterior capsular tear. Removing the haptics from the fibrosed capsule can also be hazardous, as it may result in zonular stress and dehiscence. A technique is described for performing foldable (one-piece acrylic) IOL removal without cutting the optic. Careful visco-dissection of the haptics with a low viscosity ophthalmic viscosurgical device (OVD) in the fibrosed peripheral capsular tunnel avoids zonular or capsular stress. Internal wound enlargement permits foldable IOL removal in one piece, whilst preserving a self-sealing sutureless corneal wound. This technique may enhance the safety and efficacy of foldable IOL exchange.

  14. Differential expression of extracellular matrix genes in glenohumeral capsule of shoulder instability patients.

    Science.gov (United States)

    Belangero, Paulo Santoro; Leal, Mariana Ferreira; Figueiredo, Eduardo Antônio; Cohen, Carina; Andreoli, Carlos Vicente; Smith, Marília Cardoso; Pochini, Alberto de Castro; Ejnisman, Benno; Cohen, Moises

    2016-07-01

    Anterior shoulder instability is a common orthopedic problem. After a traumatic shoulder dislocation, patients present a plastic deformation of the capsule. The shoulder instability biology remains poorly understood. We evaluated the expression of genes that encode the cartilage oligomeric matrix protein (COMP), fibronectin 1 (FN1), tenascin C (TNC) and tenascin XB (TNXB) in the glenohumeral capsule of anterior shoulder instability patients and controls. Moreover, we investigated the associations between gene expression and clinical parameters. The gene expression was evaluated by quantitative reverse transcription-polymerase chain reaction in the antero-inferior (macroscopically injured region), antero-superior and posterior regions of the capsule of 29 patients with shoulder instability and 8 controls. COMP expression was reduced and FN1 and TNC expression was increased in the antero-inferior capsule region of cases compared to controls (p shoulder instability patients (p = 0.022). COMP expression was reduced in the antero-inferior region compared to the posterior region of shoulder instability patients (p = 0.007). In the antero-inferior region, FN1 expression was increased in the capsule of patients with more than one year of symptoms (p = 0.003) and with recurrent dislocations (p = 0.004) compared with controls. FN1 and TNXB expression was correlated with the duration of symptoms in the posterior region (p shoulder instability patients. Dislocation episodes modify FN1, TNC and TNXB expression in the injured tissue. COMP altered expression may be associated with capsule integrity after shoulder dislocation, particularly in the macroscopically injured portion. PMID:27093129

  15. Anterior dental microwear texture analysis of the Krapina Neandertals

    Science.gov (United States)

    Krueger, Kristin; Ungar, Peter

    2012-12-01

    Some Neandertal anterior teeth show unusual and excessive gross wear, commonly explained by non-dietary anterior tooth use, or using the anterior dentition as a tool, clamp, or third hand. This alternate use is inferred from aboriginal arctic populations, who used their front teeth in this manner. Here we examine anterior dental microwear textures of the Krapina Neandertals to test this hypothesis and further analyze tooth use in these hominins. Microwear textures from 17 Krapina Dental People were collected by white-light confocal profilometry using a 100x objective lens. Four adjacent scans were generated, totaling an area of 204x276 μm, and were analyzed using Toothfrax and SFrax SSFA software packages. The Neandertals were compared to six bioarchaeological/ethnographic samples with reported variation in diet, abrasive load, and non-dietary anterior tooth use. Results indicate that Krapina anterior teeth lack extreme microwear textures expected of hominins exposed to heavy abrasives or those that regularly generated high stresses associated with intense use of the front teeth as tools. Krapina hominins have microwear attributes in common with Coast Tsimshian, Aleut, and Puye Pueblo samples. Collectively, this suggests that the Krapina Neandertals faced moderate abrasive loads and only periodically used their anterior teeth as tools for non-diet related behaviors.

  16. Luneburg lens in silicon photonics

    OpenAIRE

    Di Falco, Andrea; Kehr, Susanne C; Leonhardt, Ulf

    2011-01-01

    The Luneburg lens is an aberration-free lens that focuses light from all directions equally well. We fabricated and tested a Luneburg lens in silicon photonics. Such fully-integrated lenses may become the building blocks of compact Fourier optics on chips. Furthermore, our fabrication technique is sufficiently versatile for making perfect imaging devices on silicon platforms. (C) 2011 Optical Society of America

  17. Anterior cruciate ligament (ACL) injury

    Science.gov (United States)

    Cruciate ligament injury - anterior; ACL injury; Knee injury - anterior cruciate ligament (ACL) ... knee. It prevents the knee from bending out. Anterior cruciate ligament (ACL) is in the middle of the knee. ...

  18. Quantitative Analysis of Lens Nuclear Density Using Optical Coherence Tomography (OCT with a Liquid Optics Interface: Correlation between OCT Images and LOCS III Grading

    Directory of Open Access Journals (Sweden)

    You Na Kim

    2016-01-01

    Full Text Available Purpose. To quantify whole lens and nuclear lens densities using anterior-segment optical coherence tomography (OCT with a liquid optics interface and evaluate their correlation with Lens Opacities Classification System III (LOCS III lens grading and corrected distance visual acuity (BCVA. Methods. OCT images of the whole lens and lens nucleus of eyes with age-related nuclear cataract were analyzed using ImageJ software. The lens grade and nuclear density were represented in pixel intensity units (PIU and correlations between PIU, BCVA, and LOCS III were assessed. Results. Forty-seven eyes were analyzed. The mean whole lens and lens nuclear densities were 26.99 ± 5.23 and 19.43 ± 6.15 PIU, respectively. A positive linear correlation was observed between lens opacities (R2 = 0.187, p<0.01 and nuclear density (R2 = 0.316, p<0.01 obtained from OCT images and LOCS III. Preoperative BCVA and LOCS III were also positively correlated (R2 = 0.454, p<0.01. Conclusions. Whole lens and lens nuclear densities obtained from OCT correlated with LOCS III. Nuclear density showed a higher positive correlation with LOCS III than whole lens density. OCT with a liquid optics interface is a potential quantitative method for lens grading and can aid in monitoring and managing age-related cataracts.

  19. Coherent fiber optic sensor for early detection of cataractogenesis in a human eye lens

    Science.gov (United States)

    Dhadwal, Harbans S.; Ansari, Rafat R.; Dellavecchia, Michael A.

    1993-01-01

    A lensless backscatter fiber optic probe is used to measure the size distribution of protein molecules inside an excised, but intact, human eye lens. The fiber optic probe, about 5 mm in diameter, can be positioned arbitrarily close to the anterior surface of the eye; it is a trans-receiver, which delivers a Gaussian laser beam into a small region inside the lens and provides a coherent detection of the laser light scattered by the protein molecules in the backward direction. Protein sizes determined from the fast and slow diffusion coefficients show good correlation with the age of the lens and cataractogenesis.

  20. Lens density tracking in mice by Scheimpflug imaging.

    Science.gov (United States)

    Puk, Oliver; de Angelis, Martin Hrabĕ; Graw, Jochen

    2013-08-01

    Scheimpflug imaging has recently been established for in vivo imaging of the anterior eye segment and quantitative determination of lens transparency in the mouse. This enables more effective investigations of cataract formation with the mouse model, including longitudinal studies. In order to enable recognition of disease-associated irregularities, we performed Scheimpflug measurements with the common laboratory inbred lines C57BL/6J, C3HeB/FeJ, FVB/NCrl, BALB/cByJ, and 129/SvJ in a period between 2 and 12 months of age. C57BL/6J mice showed lowest mean lens densities during the test period. Progressive cortical lens opacification was generally observed, with the earliest onset in C57BBL/6J, C3HeB/FeJ, and 129/SvJ, between 2 and 6 months after birth. Moreover, lenses of these inbred lines developed nuclear opacities. Calculated mean lens density significantly increased between 6 and 12 months of age in all inbred strains except 129/SvJ. Lens densities (and the corresponding standard deviations) of FVB/NCrl and 129/SvJ increased most likely because of differences in the genetic background. Albinism as confounder might be excluded since the albino Balb/cByJ mice are more similar to the C57BL/6J or C3Heb/FeJ mice. We further identified strain-specific anterior lens opacities (C57BL/6J) and cloudy corneal lesions (C57BL/6J, FVB/NCrl, and BALB/cByJ) at later stages. In conclusion, our results indicate that there are lifelong opacification processes in the mouse lens. The highest lens transparency and a dark coat color, which prevents interference from light reflections, make mice with the C57BL/6J background most suitable for cataract research by Scheimpflug imaging. We show that lens densitometry by Scheimpflug imaging in mouse eyes can resolve differences of less than 1 %, making it possible to detect differences in cataract development in different mouse strains, even if they are small. PMID:23929037

  1. Family love time capsule preview

    CERN Document Server

    Musgrave, Jim

    2015-01-01

    Create your own family time capsule online using EMRE Publishing's ePub3 Creator Studio. With our storage plans, your family videos, music playlists and mysteries can be preserved for coming generations to add to, embellish, and communicate using our Family Forum inside the Embellisher eReader for multimedia ""enhanced"" eBooks. Just like the ""American Sniper"" enhanced eBook, you can pay tribute to your fallen heroes and other family members who have distinguished themselves in life.

  2. Transglutaminase involvement in UV-A damage to the eye lens.

    Science.gov (United States)

    Weinreb, O; Dovrat, A

    1996-11-01

    Solar radiation is believed to be one of the major environmental factors involved in lens cataractogenesis. The purpose of the study was to investigate the mechanisms by which UV-A at 365 nm causes damage to the eye lens. Bovine lenses were placed in special culture cells for pre-incubation of 24 hr. The lenses were positioned so that the anterior surface faced the incident UV-A radiation source and were maintained in the cells during irradiation. After irradiation, lens optical quality was monitored throughout the culture period and lens epithelium, cortex and nuclear samples were taken for biochemical analysis. Transglutaminase activity in the lens was affected by the radiation. The activity of transglutaminase in lens epithelium cortex and nucleus increased as a result of the irradiation and then declined towards control levels during the culture period, as the lens recovered from the UV-A damage. Specific lens proteins, alpha B and beta B1 crystallins (the enzyme substrates) were analyzed by SDS polyacrylamide gel electrophoresis and immunoblotting with specific antibodies. Seventy-two hours after irradiation of 44.8 J cm-2 UV-A, alpha B crystallins were affected as was shown by the appearance of aggregation and degradation products. Some protein changes seem to be reversible. It appears that transglutaminase may be involved in the mechanism by which UV-A causes damage to the eye lens.

  3. Conservative treatment of an anterior-lateral ankle dislocation without an associated fracture in a diabetic patient: a case report

    Directory of Open Access Journals (Sweden)

    Panagiotis K. Karampinas

    2012-06-01

    Full Text Available Anterior or anterior-lateral dislocation of the ankle is a rare condition that can be treated conservatively as well as any other similar types of ankle dislocations without associated fractures. We present a case report of an anterior-lateral ankle dislocation with a concomitant avulsion injury of the ankle's anterior capsule in a diabetic patient that was treated conservatively. At the patient's visit 12 months after the initial injury, he was asymptomatic with full range of motion of the ankle joint. To our knowledge, we could not identify this type of an injury in a diabetic patient that was treated successfully with conservative treatment in the existing literature.

  4. Aspherical Lens Design Using Genetic Algorithm for Reducing Aberrations in Multifocal Artificial Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Chih-Ta Yen

    2015-09-01

    Full Text Available A complex intraocular lens (IOL design involving numerous uncertain variables is proposed. We integrated a genetic algorithm (GA with the commercial optical design software of (CODE V to design a multifocal IOL for the human eye. We mainly used an aspherical lens in the initial state to the crystalline type; therefore, we used the internal human eye model in the software. The proposed optimized algorithm employs a GA method for optimally simulating the focusing function of the human eye; in this method, the thickness and curvature of the anterior lens and the posterior part of the IOL were varied. A comparison of the proposed GA-designed IOLs and those designed using a CODE V built-in optimal algorithm for 550 degrees myopia and 175 degrees astigmatism conditions of the human eye for pupil size 6 mm showed that the proposed IOL design improved the spot size of root mean square (RMS, tangential coma (TCO and modulation transfer function (MTF at a spatial frequency of 30 with a pupil size of 6 mm by approximately 17%, 43% and 35%, respectively. However, the worst performance of spherical aberration (SA was lower than 46%, because the optical design involves a tradeoff between all aberrations. Compared with the traditional CODE V built-in optimal scheme, the proposed IOL design can efficiently improve the critical parameters, namely TCO, RMS, and MTF.

  5. Asymmetric Membrane Osmotic Capsules for Terbutaline Sulphate

    OpenAIRE

    Gobade, N. G.; Marina Koland; K H Harish

    2012-01-01

    The aim of the present study was to design an asymmetric membrane capsule, an osmotic pump-based drug delivery system of ethyl cellulose for controlled release of terbutaline sulphate. asymmetric membrane capsules contains pore-forming water soluble additive, sorbitol in different concentrations in the capsule shell membrane, which after coming in contact with water, dissolves, resulting in an in situ formation of a microporous structure. The terbutaline sulphate is a β-adrenoreceptor agonist...

  6. Iris reconstruction combined with iris-claw intraocular lens implantation for the management of iris-lens injured patients

    Science.gov (United States)

    Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan

    2016-01-01

    Aim: To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Settings and Design: Retrospective, noncomparable consecutive case series study. Materials and Methods: Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Results: Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or <20/1000. Within a 1.1–4.2-year follow-up period, a significant increase, equal to or better than 20/66, in UCVA was observed in six (55%) cases, and in best-corrected VA (BCVA) was observed in nine (82%) cases. Postoperative BCVA was 20/40 or better in seven cases (64%). After combined surgery, the iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Conclusions: Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support. PMID:27146932

  7. Regulation of capsule in Neisseria meningitidis.

    Science.gov (United States)

    Tzeng, Yih-Ling; Thomas, Jennifer; Stephens, David S

    2016-09-01

    Neisseria meningitidis, a devastating pathogen exclusive to humans, expresses capsular polysaccharides that are the major meningococcal virulence determinants and the basis for successful meningococcal vaccines. With rare exceptions, the expression of capsule (serogroups A, B, C, W, X, Y) is required for systemic invasive meningococcal disease. Changes in capsule expression or structure (e.g. hypo- or hyper-encapsulation, capsule "switching", acetylation) can influence immunologic diagnostic assays or lead to immune escape. The loss or down-regulation of capsule is also critical in meningococcal biology facilitating meningococcal attachment, microcolony formation and the carriage state at human mucosal surfaces. Encapsulated meningococci contain a cps locus with promoters located in an intergenic region between the biosynthesis and the conserved capsule transport operons. The cps intergenic region is transcriptionally regulated (and thus the amount of capsule expressed) by IS element insertion, by a two-component system, MisR/MisS and through sequence changes that result in post-transcriptional RNA thermoregulation. Reversible on-off phase variation of capsule expression is controlled by slipped strand mispairing of homo-polymeric tracts and by precise insertion and excision of IS elements (e.g. IS1301) in the biosynthesis operon. Capsule structure can be altered by phase-variable expression of capsular polymer modification enzymes or "switched" through transformation and homologous recombination of different polymerases. Understanding the complex regulation of meningococcal capsule has important implications for meningococcal biology, pathogenesis, diagnostics, current and future vaccine development and vaccine strategies. PMID:26089023

  8. Functional modular contact lens

    Science.gov (United States)

    Shum, Angela J.; Cowan, Melissa; Lähdesmäki, Ilkka; Lingley, Andrew; Otis, Brian; Parviz, Babak A.

    2009-08-01

    Tear fluid offers a potential route for non-invasive sensing of physiological parameters. Utilization of this potential depends on the ability to manufacture sensors that can be placed on the surface of the eye. A contact lens makes a natural platform for such sensors, but contact lens polymers present a challenge for sensor fabrication. This paper describes a microfabrication process for constructing sensors that can be integrated into the structure of a functional contact lens in the future. To demonstrate the capabilities of the process, an amperometric glucose sensor was fabricated on a polymer substrate. The sensor consists of platinum working and counter electrodes, as well as a region of indium-tin oxide (ITO) for glucose oxidase immobilization. An external silver-silver chloride electrode was used as the reference electrode during the characterization experiments. Sensor operation was validated by hydrogen peroxide measurements in the 10- 20 μM range and glucose measurements in the 0.125-20 mM range.

  9. [Glomus tumor of volar elbow capsule. Case report].

    Science.gov (United States)

    Burnier, M; Erhard, L

    2014-02-01

    Glomus tumors are rare tumors, benign but painful and responsible for a major functional impairment. Although their preferential localization is digital, 35% of glomus tumors are extradigital. Ignorance of this disease characterized by atypical clinical signs and the absence of specific imaging are responsible for a significant diagnostic delay, 7 to 10 years in extradigital forms. Treatment by surgical excision simply ensures immediate disappearance of pain without recurrence in 90% of cases. It is therefore necessary to emphasize the existence of this sometimes debilitating condition benefiting from effective therapeutic solution. We report the case of a glomus tumor of the anterior capsule of the left elbow in a 24-year-old woman with a diagnostic delayed by 12 years. PMID:24394237

  10. Impact of Laser Capsulotomy in the Quality of Life of the Elderly with Posterior Capsule Opacity after Cataract Surgery

    Directory of Open Access Journals (Sweden)

    Armando Rafael Milanés Armengol

    2013-04-01

    Full Text Available Background: the opacity of the posterior lens capsule after cataract surgery has decreased in recent years but its incidence remains high.Objective: To assess the impact of the opacification of the posterior lens capsule and its treatment with laser capsulotomy on visual function and life quality of patients after cataract surgery. Methods: A case series study of elderly patients with diagnose of opacity in the posterior lens capsule after cataract surgery who were treated with laser capsulotomy from January 2010 to January 2011 in the General University Hospital of Cienfuegos was conducted. A survey and a battery of assessment tools to measure functional status were applied as well as the VF-14 test for the assessment of life quality. Results: We observed an improvement in the average value of the visual acuity (0, 326 by 0, 726 practiced capsulotomy to later, with an average range of efficiency improvement of a binocular visual 6.96%, likewise improved functional visual capacity from 57, 728 to 96, 223; exploration by VF-14 showed a higher life quality. The degree of overall validism was recovered in 86, 56 % of patients and only one patient was totally dependent for the realization of daily life activities. Conclusions: Patients who underwent laser capsulotomy showed evidence of improvement in visual acuity, functionality and life quality.

  11. Case of late-onset corneal decompensation after iris-fixated phakic intraocular lens implantation.

    NARCIS (Netherlands)

    Eijden, R. van; Vries, N.E. de; Cruysberg, L.P.J.; Webers, C.A.; Berenschot, T.; Nuijts, R.M.

    2009-01-01

    A 48-year-old myopic patient with bilateral anterior chamber depth of 3.1 mm and endothelial cell density (ECD) of 2525 cells/mm(2) and 2638 cells/mm(2) preoperatively had bilateral implantation of an Artisan iris-fixated phakic intraocular lens (pIOL). Five years postoperatively, unilateral corneal

  12. RETAINED STONE PIECE IN ANTERIOR CHAMBER

    Directory of Open Access Journals (Sweden)

    ZvornicaninJasmin, Nadarevic-VodencarevicAmra

    2015-04-01

    Full Text Available ABSTRACT We read with interest the article by Surekha et al. regarding the retained stone piece in anterior chamber. Similar to the results of previous studies, the authors found that delayed intraocular foreign body (IOFB management can result in good visual outcome without an apparent increased risk of endophthalmitis or other deleterious side effects. However, the authors failed to explain the exact reason for the diminution of vision in patients left eye. It is unclear what the uncorrected visual acuity was and what kind of correction was used, more precisely type and amount of cylinder, given the presence of the corneal opacity. Since the size of the IOFB is approximately 4x4x1mm, significant irido-corneal angle changes resulting in intraocular pressure raise and optic nerve head damage can be expected. Traumatic glaucoma following open globe injury can occur in 2.7 to 19% of cases, with several risk factors associated with glaucoma development (advanced age, poor visual acuity at presentation,perforating rather than penetrating ocular injury,lens injury, presence of vitreous hemorrhage and presence of an IOFB. Earlier reportsof latetraumaticoptic neuropathy onset, even after several years, indicate that this possibility cannot be completely ruled out too. Therefore, repeated intraocular pressure measurements, gonioscopy, pupillary reaction assessment, together with through posterior segment examination including visual field and optical coherence tomography examinations can be useful in determining the possible optic nerve damage as one of the possible reasons for visual acuity reduction. The authors did not suggest any operative treatment at this time. However, it should bear in mind that the inert anterior chamber IOFB could be a risk factor for non-infectious endophthalmitis development even after many years. Also, long term retained anterior chamber foreign body leads to permanent endothelial cell loss and can even result in a corneal

  13. Foreign Body Embedded in Anterior Chamber Angle

    Directory of Open Access Journals (Sweden)

    Shmuel Graffi

    2012-01-01

    Full Text Available Introduction. We present a case of a metallic foreign body embedded in the anterior chamber angle. After standing in close proximity to a construction worker breaking a tile, a 26-year-old woman using soft contact lens for the correction of mild myopia presented to emergency department for evaluation of a foreign body sensation of her right eye. Methods and Results. Diagnosis was confirmed by gonioscopic examination and a noncontrast CT scan of head and orbits. The foreign body was removed by an external approach without utilizing a magnet. The patient's final outcome was favorable. Discussion. The above is a rare clinical situation, which is impossible to detect on slit-lamp examination without a gonioscopic view. Proper imaging and a specific management are mandatory in order to achieve favorable outcome.

  14. LASER INDUCED THERMAL LENS EFFECT

    Institute of Scientific and Technical Information of China (English)

    沈俊; 黄孟才; 江景云; 施教芳

    1991-01-01

    The thermal lens effect has emerged in recent years as a novel ,highly sensitive tool for the study of the very weak molecular absorption of light energy,This paper discusses the theory and technique of the thermal lens measurement.Some opplications of the thermal lens measurement are described.A mode-mismatched dual-beam thermal lens experimental arragement with a modulated probe beam ,designed by the authors.for trace analysis is presented,and its detection limit was found to be 4.1×10-7 for Cu(Ⅱ) in ethanol and 80 mW excitation power.

  15. The balanced two-string technique for sulcus intraocular lens implantation in the absence of capsular support.

    Science.gov (United States)

    Ibrahim, Hesham A; Sabry, Heba Nabil

    2015-01-01

    Purpose. To describe and explore an alternative approach for sulcus intraocular lens (IOL) implantation in the absence of capsular support. Methods. The commonly available one-piece poly(methyl methacrylate) (PMMA) lens is stabilized in the sulcus by two intraocular horizontal strings of 10/0 polypropylene suture passed through the lens dialing holes in opposite directions to achieve a mechanical balance. The horizontal strings of 10/0 polypropylene work as a rail track for the IOL optics, allowing some side to side lens adjustment even following wound closure. The stability of the IOL was tested in vitro. Six aphakic patients underwent in-sulcus IOL secondary implantation using the balanced two-string technique. Patients were followed up for a minimum of six months. Best spectacle corrected vision was assessed. Lens centration and lens tilt were measured by anterior segment optical coherence tomography (AS-OCT). Results. All patients had successful lens insertion. Best spectacle corrected visual acuity (BSCVA) improved in all patients. Lens decentration ranged between 0.21 mm and 0.9 mm (average 0.53 mm). Lens tilt ranged between 1.2° and 2.8° (average 2.17°). Conclusion. The mechanically balanced two-string technique is an alternative option for sulcus IOL implantation in absence of capsular support, allowing lens centration adjustment with no additional risks.

  16. The Balanced Two-String Technique for Sulcus Intraocular Lens Implantation in the Absence of Capsular Support

    Directory of Open Access Journals (Sweden)

    Hesham A. Ibrahim

    2015-01-01

    Full Text Available Purpose. To describe and explore an alternative approach for sulcus intraocular lens (IOL implantation in the absence of capsular support. Methods. The commonly available one-piece poly(methyl methacrylate (PMMA lens is stabilized in the sulcus by two intraocular horizontal strings of 10/0 polypropylene suture passed through the lens dialing holes in opposite directions to achieve a mechanical balance. The horizontal strings of 10/0 polypropylene work as a rail track for the IOL optics, allowing some side to side lens adjustment even following wound closure. The stability of the IOL was tested in vitro. Six aphakic patients underwent in-sulcus IOL secondary implantation using the balanced two-string technique. Patients were followed up for a minimum of six months. Best spectacle corrected vision was assessed. Lens centration and lens tilt were measured by anterior segment optical coherence tomography (AS-OCT. Results. All patients had successful lens insertion. Best spectacle corrected visual acuity (BSCVA improved in all patients. Lens decentration ranged between 0.21 mm and 0.9 mm (average 0.53 mm. Lens tilt ranged between 1.2° and 2.8° (average 2.17°. Conclusion. The mechanically balanced two-string technique is an alternative option for sulcus IOL implantation in absence of capsular support, allowing lens centration adjustment with no additional risks.

  17. How helpful is capsule endoscopy to surgeons?

    Institute of Scientific and Technical Information of China (English)

    Osman Ersoy; Bulent Sivri; Yusuf Bayraktar

    2007-01-01

    Capsule endoscopy is a new technology that, for the first time, allows complete, non-invasive endoscopic imaging of the small bowel. The efficacy of capsule endoscopy in the diagnosis of suspected small bowel diseases has been established. Important applications for surgeons include observations of obscure gastrointestinal bleeding and small bowel neoplasms.

  18. The future of wireless capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    We outline probable and possible developments with wireless capsule endoscopy. It seems likely that capsule endoscopy will become increasingly effective in diagnostic gastrointestinal endoscopy. This will be attractive to patients especially for cancer or varices detection because capsule endoscopy is painless and is likely to have a higher take up rate compared to conventional colonoscopy and gastroscopy. Double imager capsules with increased frame rates have been used to image the esophagus for Barrett's and esophageal varices. The image quality is not bad but needs to be improved if it is to become a realistic substitute for flexible upper and lower gastrointestinal endoscopy. An increase in the frame rate, angle of view, depth of field, image numbers, duration of the procedure and improvements in illumination seem likely. Colonic, esophageal and gastric capsules will improve in quality, eroding the supremacy of flexible endoscopy, and become embedded into screening programs. Therapeutic capsules will emerge with brushing, cytology, fluid aspiration, biopsy and drug delivery capabilities. Electrocautery may also become possible. Diagnostic capsules will integrate physiological measurements with imaging and optical biopsy, and immunologic cancer recognition. Remote control movement will improve with the use of magnets and/or electrostimulation and perhaps electromechanical methods. External wireless commands will influence capsule diagnosis and therapy and will increasingly entail the use of real-time imaging. However, it should be noted that speculations about the future of technology in any detail are almost always wrong.

  19. Congenital anterior urethral diverticulum.

    Science.gov (United States)

    Singh, Sanjeet Kumar; Ansari, Ms

    2014-09-01

    Congenital anterior urethral diverticulum (CAUD) may be found all along the anterior urethra and may present itself at any age, from infant to adult. Most children with this condition present with difficulty in initiating micturition, dribbling of urine, poor urinary stream, or urinary tract infection. A careful history will reveal that these children never had a good urinary stream since birth, and the telltale sign is a cystic swelling of the penile urethra. In this paper, we present two cases of CAUD that were managed by excision of the diverticulum with primary repair. PMID:26328174

  20. 7.1 T MRI to Assess the Anterior Segment of the Eye

    NARCIS (Netherlands)

    Langner, Soenke; Martin, Heiner; Terwee, Thom; Koopmans, Steven A.; Krueger, Paul C.; Hosten, Norbert; Schmitz, Klaus-Peter; Guthoff, Rudolf F.; Stachs, Oliver

    2010-01-01

    PURPOSE. Visualization of the anterior segment and biometric evaluation of the entire crystalline lens pose significant challenges for imaging techniques because of tissue-induced distortion artifacts. The present study was conducted to demonstrate the advantages of high-resolution magnetic resonanc

  1. Physics of electrostatic lens

    Science.gov (United States)

    1981-09-01

    The purpose of this program was to study the physics of the ion-energy boosting electrostatic lens for collective ion acceleration in the Luce diode. Extensive work was done in preparation for experiments on the PI Pulserad 1150. Analytic work was done on the orbit of protons in a mass spectrometer and a copper stack for nuclear activation analysis of proton energy spectrum has been designed. Unfortunately, a parallel program which would provide the Luce diode for the collective ion acceleration experiment never materialized. As a result no experiments were actually performed on the Pulserad 1150.

  2. Adhesive capsulitis of the shoulder: MR arthrography

    International Nuclear Information System (INIS)

    Adhesive capsulitis is a clinical syndrome involving pain and decreased joint motion caused by thickening and contraction of the joint capsule. The purpose of this study is to describe the MR arthrographic findings of this syndrome. Twenty-nine sets of MR arthrographic images were included in the study. Fourteen patients had adhesive capsulitis diagnosed by physical examination and arthrography, and their MR arthrographic findings were compared with those of 15 subjects in the control group. The images were retrospectively reviewed with specific attention to the thickness of the joint capsule, volume of the axillary pouch (length, width, height(depth)), thinkness of the coracohumeral ligament, presence of extra-articular contrast extravasation, and contrst filling of the subcoracoid bursa. Mean capsular thickness measured at the inferior portion of the axillary pouch was 4.1 mm in patients with adhesive capsulitis and 1.5 mm in the control group. The mean width of the axillary pouch was 2.5 mm in patients and 9.5 mm in controls. In patients, the capsule was significantly thicker and the axillary pouch significantly narrower than in controls (p<0.05). Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch (sensitivity 93%, specificity 80%) and a pouch narrower than 3.5 mm (sensitivity 93%, specificity 100%) were useful criteria for the diagnosis of adhesive capsulitis. In patients with this condition, extra-articular contrast extravasation was noted in six patients (43%) and contrast filling of the subcoracoid bursa in three (21%). The MR arthrographic findings of adhesive capsulitis are capsular thickening, a low-volume axillary pouch, extra-articular contrast extravasation, and contrast filling of the subcoracoid bursa. Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch and a pouch width of less than 3.5 mm are useful diagnostic imaging characteristics

  3. claw intraocular lens

    OpenAIRE

    Gonnermann, Johannes

    2015-01-01

    There is a wide range of alternative fixation techniques of intraocular lenses in the absence of adequate capsular support, such as angle- or iris-supported anterior chamber lenses and intra- / transsclerally-fixated (suture, fibrin glue, etc.) and iris-supported posterior chamber lenses. All procedures have different advantages and disadvantages depending on the anatomical situation and integrity of the capsular bag complex and the neighboring structures such as the iris, sclera and corneal ...

  4. Hydrodynamick instabilities on ICF capsules

    International Nuclear Information System (INIS)

    This article summarizes our current understanding of hydrodynamic instabilities as relevant to ICF. First we discuss classical, single mode Rayleigh-Taylor instability, and nonlinear effects in the evolution of a single mode. Then we discuss multimode systems, considering: (1) the onset of nonlinearity; (2) a second order mode coupling theory for weakly nonlinear effects, and (3) the fully nonlinear regime. Two stabilization mechanisms relevant to ICF are described next: gradient scale length and convective stabilization. Then we describe a model which is meant to estimate the weakly nonlinear evolution of multi-mode systems as relevant to ICF, given the short-wavelength stabilization. Finally, we discuss the relevant code simulation capability, and experiments. At this time we are quite optimistic about our ability to estimate instability growth on ICF capsules, but further experiments and simulations are needed to verify the modeling. 52 refs

  5. The Haller's organ roof and anterior pit setae of Argas ticks (Ixodoidea: Argasidae). Subgenera Secretargas and Ogadenus.

    Science.gov (United States)

    Hoogstraal, H; Clifford, C M; Roshdy, M A

    1984-06-01

    Adults of the Argas subgenera Secretargas (3 species) and Ogadenus (1 species) were studied by scanning electron microscopy. In each species, the anterior pit and Haller's organ are situated in a large dorsal hump of Tarsus I and the 9 setae of the anterior pit are characteristic of the genus Argas in structure and numbers. In A. (S.) transgariepinus, an Ethiopian-Palearctic crevice-dwelling parasite of bats, the Haller's organ capsule roof is solid with a slitlike transverse aperture. In A. (S.) hoogstraali and A. (S.) echinops, Malagasy soil-dwelling parasites of Oplurus (Varanidae) lizards and the hedgehog-tenrec (Insectivora: Tenrecidae), respectively, the Haller's organ is virtually unroofed but partially screened by arborescent dorsal projections from the posterior wall of the capsule, and the open capsule contains numerous fine pleomorphs. In A. (O.) brumpti, a soil-dwelling parasite of the hyrax (Procavia), other terrestrial mammals, and lizards in the Ethiopian Region, the capsule is also virtually unroofed and contains numerous fine pleomorphs. The unroofed capsule is probably phylogenetically primitive and occurs only in these 3 and 2 other Argas species. The soil microhabitat (in Argas confined to 3 of the 4 species recorded here), and the reptile or ancient mammal hosts of these 3 species, as well as the zoogeographical isolation of 2 of the species in the Malagasy Region, are distinctive in this genus of 56 species. The interrelationships between an unroofed Haller's organ capsule and unusual biological properties remain to be determined.

  6. Advances in material capsule technology in HANARO

    International Nuclear Information System (INIS)

    A material capsule system has been developed for irradiation tests of non-fissile materials in HANARO. This capsule system has been actively utilized for various material irradiation tests requested by users from research institutes, universities, and the industries. Based on the accumulated experience and the user's sophisticated requirements, several advances in material capsule technologies were obtained recently for a more precise control and analysis of the neutron irradiation effect in HANARO. New instrumented capsule technologies for a more precise control of the irradiation temperature and fluence of a specimen, irrespective of the reactor operation, have been developed and out-pile tested. The OR/IP capsule technologies for an irradiation test in the HANARO OR and IP test holes with a relatively lower neutron flux than the CT and IR test holes have also been developed and in-pile tested, successfully. A high temperature irradiation technology up to 1000degC is under development. An evaluation of the DPA (Displacement Per Atom) and activation of irradiated specimens was attempted by using the SPECTOR and ORIGEN2 codes, respectively. A new fluence monitor with a decreased activity was designed to measure the thermal and fast neutron fluences of the irradiated specimens. A friction welded tube using STS304 and Al1050 alloys was introduced to prevent a coolant leakage into a capsule during a capsule cutting process after an irradiation. (author)

  7. [Evaluation of nopal capsules in diabetes mellitus].

    Science.gov (United States)

    Frati Munari, A C; Vera Lastra, O; Ariza Andraca, C R

    1992-01-01

    To find out if commercial capsules with dried nopal (prickle-pear cactus, Opuntia ficus indica may have a role in the management of diabetes mellitus, three experiments were performed: 30 capsules where given in fasting condition to 10 diabetic subjects and serum glucose was measured through out 3 hours; a control test was performed with 30 placebo capsules. OGTT with previous intake of 30 nopal or placebo capsules was performed in ten healthy individuals. In a crossover and single blinded study 14 diabetic patients withdrew the oral hypoglycemic treatment and received 10 nopal or placebo capsules t.i.d. during one week; serum glucose, cholesterol and tryglycerides levels were measured before and after each one-week period. Five healthy subjects were also studied in the same fashion. Opuntia capsules did not show acute hypoglycemic effect and did not influence OGTT. In diabetic patients serum glucose, cholesterol and tryglycerides levels did not change with Opuntia, but they increased with placebo (P nopal, while cholesterol and triglycerides decreased (P < 0.01 vs. placebo). The intake of 30 Opuntia capsules daily in patients with diabetes mellitus had a discrete beneficial effect on glucose and cholesterol. However this dose is unpractical and at present it is not recommended in the management of diabetes mellitus. PMID:1307994

  8. [Karyosphere capsule in Tribolium castaneum oocytes].

    Science.gov (United States)

    Batalova, F M; Bogoliubov, D S

    2013-01-01

    Structure and composition of the karyosphere (karyosome) capsule were studied in the oocytes of a laboratory insect, Tribolium castaneum, with the use of electron microscopy and immunoelectron cytochemistry. Basing on the study of nuclear structure dynamics, we distinguished 8 stages that characterize the period of oocyte growth. At the diplotene stage, T. castaneum oocyte chromosomes conjoin early into a compact karyosphere, but a significant chromatin condensation does not occur. The process of karyosphere formation is accompanied by the development of an extensive extrachromosome capsule surrounding chromatin. The capsule consists of a material of different morphological types. Significant molecular components of the T. castaneum karyosphere capsule are represented by the proteins of nuclear matrix including F-actin and lamin B. Besides the structural proteins, the Sm proteins of small nuclear (sn) RNPs and mature 2,2,7-trimethyl guanosine (TMG) 5'-capped snRNAs are revealed immunocytochemically in the karyosphere capsule. The obtained data can form a basis for further expansion of ideas on the functions of the karyosphere capsule as a specialized extrachromosomal nuclear domain of the oocytes. We believe that the T. castaneum karyosphere capsule plays not only a structural role, but may be involved directly in the processes related to gene expression.

  9. Ectopic intraocular lens: An unusual complication of cataract surgery

    Directory of Open Access Journals (Sweden)

    Mehul A Shah

    2014-01-01

    Full Text Available We wish to report an unusual complication of intraocular lens (IOL insertion following uneventful phacoemulsification. After successful phacoemulsification surgery, a hydrophobic acrylic IOL was loaded in the injector for insertion into the capsular bag. During insertion, the IOL inadvertently extended into the corneal stromal lamella. The complication was recognized at a late stage, and the foldable acrylic lens was retrieved and reinserted correctly in the bag. The anterior chamber was made viscoelastically taut and was maintained in this state for 10 min, followed by a routine viscoelastic wash and air bubble injection. Cornea was slightly edematous with stromal haze, and the corneal thickness was 908 μm. At the 1-month follow-up visit, the patient′s vision was 20/40, the stromal haze had subsided, the corneal thickness was 572 μm, and the patient was comfortable. Though it was unknown complication, following proper management patient recovered satisfactorily.

  10. Application of ultrasound biomicro-scopy in the planning of cataract surgery in anterior megalophthalmos

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Zare

    2011-01-01

    Full Text Available Anterior megalophthalmos, a rare hereditary disorder, is macrocornea (horizontal corneal diameter more than 13 mm in association with enlarged lens-iris diaphragm and ciliary ring. One of the major challenging issues in the cataract surgery of these patients is preventing intraocular lens (IOL malposition, because of probable large capsular bag. Several approaches have been selected by previous surgeons, such as, custom-made anterior chamber IOLs. In this study, we show a normal capsular bag diameter despite ciliary ring enlargement, with application of ultrasound biomicroscopy (UMB. We suggest that in cases of anterior megalophthalmos without phacodonesis, UBM could measure the actual size of the capsular bag and obviate the need for further procedures.

  11. Evaluation of Anterior Segment's Structures in Tilted Disc Syndrome

    Science.gov (United States)

    Ozsoy, Ercan; Demirel, Ersin Ersan; Cumurcu, Tongabay

    2016-01-01

    Purpose. To evaluate anterior segment's structures by Pentacam in patients with tilted disc syndrome (TDS). Methods. Group 1 included forty-six eyes of forty-six patients who have the TDS. Group 2 including forty-six eyes of forty-six cases was the control group which was equal to the study group in age, gender, and refraction. A complete ophthalmic examination was performed in both groups. All cases were evaluated by Pentacam. The axial length (AL) of eyes was measured by ultrasound. Quantitative data obtained from these measurements were compared between two groups. Results. There was no statistically significant difference for age, gender, axial length, and spherical equivalent measurements between two groups (p = 0.625, p = 0.830, p = 0.234, and p = 0.850). There was a statistically significant difference for central corneal thickness (CCT), corneal volume (CV), anterior chamber angle (ACA), and pupil size measurements between two groups (p = 0.001, p = 0.0001, p = 0.003, and p = 0.001). Also, there was no statistically significant difference for anterior chamber depth (ACD), anterior chamber volume (ACV), and lens thickness (LT) measurements between two groups (p = 0.130, p = 0.910, and p = 0.057). Conclusion. We determined that CCT was thinner, CV was less, and ACA was narrower in patients with TDS. There are some changes in the anterior segment of the eyes with tilted disc. PMID:27648303

  12. Asymmetric membrane osmotic capsules for terbutaline sulphate

    Directory of Open Access Journals (Sweden)

    N G Gobade

    2012-01-01

    Full Text Available The aim of the present study was to design an asymmetric membrane capsule, an osmotic pump-based drug delivery system of ethyl cellulose for controlled release of terbutaline sulphate. asymmetric membrane capsules contains pore-forming water soluble additive, sorbitol in different concentrations in the capsule shell membrane, which after coming in contact with water, dissolves, resulting in an in situ formation of a microporous structure. The terbutaline sulphate is a β-adrenoreceptor agonist widely used in the treatment of asthma. The oral dosage regimen of terbutaline sulphate is 5 mg twice or thrice daily, the plasma half-life is approximate 3-4 h and it produces GI irritation with extensive first pass metabolism. Hence, terbutaline sulphate was chosen as a model drug with an aim to develop controlled release system. Different formulations of ethyl cellulose were prepared by phase inversion technique using different concentrations of sorbitol as pore forming agent. It was found that the thickness of the prepared asymmetric membrane capsules was increased with increase in concentration of ethyl cellulose and pore forming agent, i.e. sorbitol. The dye release study in water and 10% sodium chloride solution indicates that, the asymmetric membrane capsules follow osmotic principle to release content. The pores formed due to sorbitol were confirmed by microscopic observation of transverse section of capsule membrane. Data of in vitro release study of terbutaline sulphate from asymmetric membrane capsules indicated that, the capsules prepared with 10% and 12.5% of ethyl cellulose and 25% of sorbitol released as much as 97.44% and 76.27% in 12 h, respectively with zero order release rate. Hence asymmetric membrane capsule of 10% ethyl cellulose and 25% of sorbitol is considered as optimum for controlled oral delivery of terbutaline sulphate.

  13. Asymmetric membrane osmotic capsules for terbutaline sulphate.

    Science.gov (United States)

    Gobade, N G; Koland, Marina; Harish, K H

    2012-01-01

    The aim of the present study was to design an asymmetric membrane capsule, an osmotic pump-based drug delivery system of ethyl cellulose for controlled release of terbutaline sulphate. asymmetric membrane capsules contains pore-forming water soluble additive, sorbitol in different concentrations in the capsule shell membrane, which after coming in contact with water, dissolves, resulting in an in situ formation of a microporous structure. The terbutaline sulphate is a β-adrenoreceptor agonist widely used in the treatment of asthma. The oral dosage regimen of terbutaline sulphate is 5 mg twice or thrice daily, the plasma half-life is approximate 3-4 h and it produces GI irritation with extensive first pass metabolism. Hence, terbutaline sulphate was chosen as a model drug with an aim to develop controlled release system. Different formulations of ethyl cellulose were prepared by phase inversion technique using different concentrations of sorbitol as pore forming agent. It was found that the thickness of the prepared asymmetric membrane capsules was increased with increase in concentration of ethyl cellulose and pore forming agent, i.e. sorbitol. The dye release study in water and 10% sodium chloride solution indicates that, the asymmetric membrane capsules follow osmotic principle to release content. The pores formed due to sorbitol were confirmed by microscopic observation of transverse section of capsule membrane. Data of in vitro release study of terbutaline sulphate from asymmetric membrane capsules indicated that, the capsules prepared with 10% and 12.5% of ethyl cellulose and 25% of sorbitol released as much as 97.44% and 76.27% in 12 h, respectively with zero order release rate. Hence asymmetric membrane capsule of 10% ethyl cellulose and 25% of sorbitol is considered as optimum for controlled oral delivery of terbutaline sulphate. PMID:23204625

  14. Effect of primary iris and ciliary body cyst on anterior chamber angle in patients with shallow anterior chamber

    Institute of Scientific and Technical Information of China (English)

    Bing-hong WANG; Yu-feng YAO

    2012-01-01

    Objective:To evaluate the prevalence of primary iris and/or ciliary body cysts in eyes with shallow anterior chamber and their effect on the narrowing of the anterior chamber angle.Methods:Among the general physical check-up population,subjects with shallow anterior chambers,as judged by van Herick technique,were recruited for further investigation.Ultrasound biomicroscope (UBM) was used to detect and measure the cysts located in the iris and/or ciliary body,the anterior chamber depth (ACD),the angle opening distance at 500 μm (AOD500),and the trabecular-iris angle (TIA).A-scan ultrasonography was used to measure the ocular biometry,including lens thickness,axial length,lens/axial length factor (LAF),and relative lens position (RLP).The effect of the cyst on narrowing the corresponding anterior chamber angle and the entire angle was evaluated by the UBM images,ocular biometry,and gonioscopic grading.The eye with unilateral cyst was compared with the eye without the cyst for further analysis.Results:Among the 727 subjects with shallow anterior chamber,primary iris and ciliary body cysts were detected in 250 (34.4%) patients; among them 96 (38.4%) patients showed unilateral single cyst,21 (8.4%) patients had unilateral double cysts,and 42 (16.8%) patients manifested unilateral multiple and multi-quadrants cysts.Plateau iris configuration was found in 140 of 361 (38.8%) eyes with cysts.The mean size of total cysts was (0.6547±0.2319) mm.In evaluation of the effect of the cyst size and location on narrowing the corresponding angle to their position,the proportion of the cysts causing corresponding angle narrowing or closure among the cysts larger than 0.8 mm (113/121,93.4%) was found to be significantly higher than that of the cysts smaller than 0.8 mm (373/801,46.6%),and a significant higher proportion was also found in the cysts located at iridociliary sulcus (354/437,81.0%) than in that at the pars plicata (131/484,27.1%).In evaluating the effect

  15. Microbiological profile of anterior chamber aspirates following uncomplicated cataract surgery

    Directory of Open Access Journals (Sweden)

    Prajna N

    1998-01-01

    Full Text Available Anterior chamber aspirate cultures were done for 66 patients who underwent either an uncomplicated intracapsular cataract extraction, extracapsular cataract extraction with posterior-chamber intraocular lens implantation, or phacoemulsification with posterior-chamber intraocular lens implantation. The aspirate was obtained at the time of wound closure. The aspirates were immediately transferred to the microbiology laboratory where one drop of the aspirate was placed on a glass slide for gram stain, and the remainder was unequally divided and inoculated into blood agar, chocolate agar and thioglycolate broth. The cultures were incubated at 37° C with 5% CO2 and held for 5 days. Of 66 patients 4 (6%, had smear-positive anterior chamber aspirates. None of the aspirates showed any growth on any of the 3 culture media used. None of the eyes in the study developed endophthalmitis. This study concludes that there is no contamination of the anterior chamber by viable bacteria after cataract surgery, irrespective of the mode of intervention.

  16. 21 CFR 520.1660b - Oxytetracycline hydrochloride capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride capsules. 520.1660b... Oxytetracycline hydrochloride capsules. (a) Specifications. The drug is in capsule form with each capsule containing 125 or 250 milligrams of oxytetracycline hydrochloride. Oxytetracycline is the...

  17. Capsule Retentions and Incomplete Capsule Endoscopy Examinations: An Analysis of 2300 Examinations

    OpenAIRE

    Charlotte M. Höög; Lars-Åke Bark; Juan Arkani; Jacob Gorsetman; Olle Broström; Urban Sjöqvist

    2011-01-01

    Aim. To evaluate capsule endoscopy in terms of incomplete examinations and capsule retentions and to find risk factors for these events. Material and Methods. This retrospective and consecutive study includes data from 2300 capsule enteroscopy examinations, performed at four different hospitals in Stockholm, Sweden from 2003 to 2009. Results. The frequency of incomplete examinations was 20%. Older age, male gender, suspected, and known Crohn's disease were risk factors for an incomplete exami...

  18. 人工晶体睫状沟缝合固定术临床观察%Clinical observation of intraocular lens ciliary sulcus suture fixation

    Institute of Scientific and Technical Information of China (English)

    沙英虹; 史要武

    2015-01-01

    Objective To investigate clinical application of intraocular lens ciliary sulcus suture fixation.Methods Posterior chamber intraocular lens ciliary sulcus suture fixation was applied for 15 patients with traumatic lens subluxation, posterior capsule injury, posterior capsule injury after senile cataract ultrasonic emulsification, and non-lens after vitrectomy. Their clinical effects were observed.Results Follow-up for 6 months showed postoperative visual acuity in 15 cases were all better than best corrected visual acuity before operation.Conclusion Implement of intraocular lens ciliary sulcus suture fixation is a safe and effective method for non-lens capsule, lens posterior capsular rupture, or wide acantholysis of lens suspensory ligament.%目的 探讨人工晶状体睫状沟缝合固定术的临床应用.方法 对15例外伤性晶体半脱位,后囊破损,老年性白内障超声乳化后囊破损,玻璃体切割术后无晶体眼患者施行后房型人工晶体(IOL)缝线固定术,观察临床效果.结果 随诊6个月,15例患者术后视力均高于术前最佳矫正视力.结论 对无晶体囊膜及晶体后囊膜破裂或晶体悬韧带大范围松解施行人工晶状体睫状沟固定术是一种安全有效的方法.

  19. Arthrographic differential diagnosis between ruptures of the anterior talofibular ligament, the joint capsule and the anterior tibiofibular ligament

    International Nuclear Information System (INIS)

    Aus einem Studium der Literatur, chirurgischen Befunden und Untersuchungen an Leichen kann es als unwahrscheinlich angesehen werden, dass bei einer Fussverstauchung vom Inversionstyp ein Riss des vorderen tibiofibularen Ligraments haeufig zusammen mit einem Gelenkkapselriss und einem seitlichen Baenderriss auftritt. Entgegen der Beobachtung anderer Verfasser fanden wir, dass ein Riss des vorderen tibiofularen Ligaments in keiner Weise aus dem Vorhandensein oder Nichtvorhandensein folgender arthrographischer Befunde geschlossen werden konnte: a) kontrastfreie Zone, b) tibiofibularer Rezessus, oder c) beide zusammen. Ein Gelenkkapselriss kann angenommen werden, wenn Kontrastmittel aus dem Gelenk in das weiche Gewebe austritt, ohne unterhalb oder seitlich in den Aussenknoechel zu dringen. Ein Austritt des Kontrastmittels unterhalb und seitlich des Aussenknoechels deutet auf einen Riss des vorderen tabofibularen Ligaments hin. Die anatomischen Zusammenhaenge zwischen Bandverbindung, Gelenkkapsel, tibiofibularem Rezessus und dem vorderen talofibularen Ligament wurden an Leichen und waehrend der chirurgischen Eingriffe studiert. Ausbreitung des Kontrastmittels im weichen Gewebe wird wahrscheinlich bestimmt durch die Anordnung und Beschaedigung der Weichteile und durch die Groesse des entstandenen Haematoms und folgt dem Weg des kleinsten Widerstandes. (orig.)

  20. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... going on here. And I’ll particularly pay attention to this tensor fascia latae. Yeah. The time ... don’t, that posterior capsule can get your attention, so what you do is you know, expose ...

  1. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... capsule. Okay. What do you think on the learning curve? 4 No, I think that’s good. I ... to the other camera, Roger, I think the learning curve in my hands is about 36, but ...

  2. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... attributed to the Jeu de brothers, Robert and John, who practiced orthopedic surgery in France in the ‘ ... So I agree completely. I know Chris and John Cagey have worked on saving the capsule. I ...

  3. Therapeutic Capsule Endoscopy: Opportunities and Challenges

    Directory of Open Access Journals (Sweden)

    Mahdi Rasouli

    2011-01-01

    Full Text Available The increasing demand for non-invasive (or less-invasive monitoring and treatment of medical conditions has attracted both physicians and engineers to work together and investigate new methodologies. Wireless capsule endoscopy is a successful example of such techniques which has become an accepted routine for diagnostic inspection of the gastrointestinal tract. This method offers a non-invasive alternative to traditional endoscopy and provides the opportunity for exploring distal areas of the small intestine which are otherwise not accessible. Despite these advantages, wireless capsule endoscopy is still limited in functionality compared to traditional endoscopy. Wireless capsule endoscopes with advanced functionalities, such as biopsy or drug delivery, are highly desirable. In this article, the current status of wireless capsule endoscopy is reviewed together with some of its possible therapeutic applications as well as the existing challenges.

  4. Capsule endoscopy in patients refusing conventional endoscopy

    OpenAIRE

    Romero-Vázquez, Javier; Argüelles-Arias, Federico; García-Montes, Josefa Maria; Caunedo-Álvarez, Ángel; Pellicer-Bautista, Francisco Javier; Herrerías-Gutiérrez, Juan Manuel

    2014-01-01

    Capsule endoscopy is nowadays the diagnostic technique of choice in the study of small bowel pathologies, allowing the non-invasive study of the entire mucosa. This has led, together with new technical advances, to the creation of two new models (PillCam ESO and PillCam Colon) for the study of esophageal and colonic diseases. These two new capsules offer an interesting alternative to conventional endoscopy in the study of the upper and lower digestive tracts, because traditional endoscopy is ...

  5. Radiocarbon dating of the human eye lens crystallines reveal proteins without carbon turnover throughout life.

    Directory of Open Access Journals (Sweden)

    Niels Lynnerup

    Full Text Available BACKGROUND: Lens crystallines are special proteins in the eye lens. Because the epithelial basement membrane (lens capsule completely encloses the lens, desquamation of aging cells is impossible, and due to the complete absence of blood vessels or transport of metabolites in this area, there is no subsequent remodelling of these fibers, nor removal of degraded lens fibers. Human tissue ultimately derives its (14C content from the atmospheric carbon dioxide. The (14C content of the lens proteins thus reflects the atmospheric content of (14C when the lens crystallines were formed. Precise radiocarbon dating is made possible by comparing the (14C content of the lens crystallines to the so-called bomb pulse, i.e. a plot of the atmospheric (14C content since the Second World War, when there was a significant increase due to nuclear-bomb testing. Since the change in concentration is significant even on a yearly basis this allows very accurate dating. METHODOLOGY/PRINCIPAL FINDINGS: Our results allow us to conclude that the crystalline formation in the lens nucleus almost entirely takes place around the time of birth, with a very small, and decreasing, continuous formation throughout life. The close relationship may be further expressed as a mathematical model, which takes into account the timing of the crystalline formation. CONCLUSIONS/SIGNIFICANCE: Such a life-long permanence of human tissue has hitherto only been described for dental enamel. In confront to dental enamel it must be held in mind that the eye lens is a soft structure, subjected to almost continuous deformation, due to lens accommodation, yet its most important constituent, the lens crystalline, is never subject to turnover or remodelling once formed. The determination of the (14C content of various tissues may be used to assess turnover rates and degree of substitution (for example for brain cell DNA. Potential targets may be nervous tissues in terms of senile or pre

  6. Towards Polymer-Based Capsules with Drastically Reduced Controlled Permeability

    Science.gov (United States)

    Andreeva, Daria V.; Sukhorukov, Gleb B.

    Small molecules (dyes, therapeutics, etc.) could be easily handled, stored, delivered, and released by polyelectrolyte capsules. To make the polyelectrolyte capsule more efficient for small molecule encapsulation, capsule permeability should be significantly decreased. Here, we demonstrate the possibility to entrap water-soluble molecular species into polyelectrolyte capsules modified by a low permeable dense polymer (polypyrrole). Possible future areas in PE capsule application as carriers for gases and volatiles in the pharmaceutical, food, and gases industry, agriculture and cosmetology are discussed.

  7. Photothermal Lens Aberration Effects in Two Laser Thermal Lens Spectrometry

    OpenAIRE

    Bialkowski, Stephen E.

    1985-01-01

    A comparison of theories describing two laser photothermal lens signals is given. The aberrant nature of this lens is accounted for in a theory which treats the propagation of a monitor laser in terms of a phase shift in this laser beam wave front. The difference between theories are discussed in terms of the predicted signal strengths and temporal behavior. The aberrant theory results in smaller theoretical signal strengths and different functional relationships between signal and analyte le...

  8. Long-Lever-Arm Manipulation Under Anesthesia With Resultant Traumatic Anterior Shoulder Dislocation.

    Science.gov (United States)

    Roubal, Paul J; Placzek, Jeffrey D

    2016-08-01

    The patient was a 61-year-old woman who underwent long-lever manipulation under anesthesia (MUA) for adhesive capsulitis. Two weeks following MUA, the constellation of clinical findings raised concern for possible adverse outcomes. Radiographs were obtained, as well as subsequent magnetic resonance imaging and computed tomography scans. Images revealed anterior shoulder dislocation with Bankart and Hill-Sachs lesions, and an anterior rotator cuff tear. J Orthop Sports Phys Ther 2016;46(8):707. doi:10.2519/jospt.2016.0412. PMID:27477474

  9. Straylight Measurements in Contact Lens Wear

    NARCIS (Netherlands)

    I.J.E. van der Meulen; L.A. Engelbrecht; J.M.J. van Vliet; R. Lapid-Gortzak; C.P. Nieuwendaal; M.P. Mourits; R.O. Schlingemann; T.J.T.P. van den Berg

    2010-01-01

    Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens remov

  10. A CASE OF ANGLE - CLOSURE GLAUCOMA SECONDARY TO CHRONIC ANTERIOR UVEITIS

    Directory of Open Access Journals (Sweden)

    Pandu

    2015-05-01

    Full Text Available Elevation of intraocular pressure secondary to intraocular inflammation frequently presents a diagnostic & therapeutic challenge. Secondary glaucoma is more common in chronic anterior uveitis. We present a case of the same, a 25 years old female presented with headache and redness in right eye. She gives history of gradual loss of vision in both eyes 15 years back. On examination there was no perception of light in both eyes and pupillary reactions were absent in both eyes. Anterior segment of right eye showed circumciliary congestion, corneal edema, peripheral anterior synechiae, Aqueous flare of grade 1+, annular posterior synechiae with complicated cataract. Anterior segment of left eye showed shallow anterior chamber with closed angles and complicated cataract. A clinical diagnosis of secondary angle closure glaucoma was made. Once IOP was under control she underwent synechotomy and lens extraction in right eye and lens extraction in left eye. Post operatively corneal edema and congestion resolved. Fundus examination revealed glaucomatous optic atrophy. Thus, prompt and early treatment of anterior uveitis is needed to prevent secondary angle closure glaucoma. We report a case of secondary angle closure glaucoma in a young female patient.

  11. Inverse Design of Electron Lens

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The inverae design of electron lens is reelized by two different methods in this paper. One isdamped leastsquare method and the other is the artificial neural network method. Their merits and defects are discussed accordingto our calculation results in the psper. In the condition of selecting the learning samples properly, the artificial neuralnetwork has obvious advantages in the inverse design of electron lens. It is an effective method to solve the inversedesign problem in the electron optic system.

  12. Contact Lens Related Corneal Ulcer

    OpenAIRE

    Loh, KY; P Agarwal

    2010-01-01

    A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...

  13. Phakic Intraocular lens- a review

    OpenAIRE

    Cruz, Francisco Miguel

    2015-01-01

    Introduction: Intraocular refractive procedures with the implantation of a Phakic Intraocular lens have become a safe efficient and predictable alternative for treating high ametropias when the use of corneal photoablative procedures is not possible. The implantation of Phakic intraocular lens preservs the accomodative function,is a reversable refractive procedure, with minimal induction of higher order aberrations compaed with corneal photoablative procedures. Methods: An analytical review o...

  14. The anterior cingulate cortex

    Directory of Open Access Journals (Sweden)

    Pavlović D.M.

    2009-01-01

    Full Text Available The anterior cingulate cortex (ACC has a role in attention, analysis of sensory information, error recognition, problem solving, detection of novelty, behavior, emotions, social relations, cognitive control, and regulation of visceral functions. This area is active whenever the individual feels some emotions, solves a problem, or analyzes the pros and cons of an action (if it is a right decision. Analogous areas are also found in higher mammals, especially whales, and they contain spindle neurons that enable complex social interactions. Disturbance of ACC activity is found in dementias, schizophrenia, depression, the obsessive-compulsive syndrome, and other neuropsychiatric diseases.

  15. A course in lens design

    CERN Document Server

    Velzel, Chris

    2014-01-01

    A Course in Lens Design is an instruction in the design of image-forming optical systems. It teaches how a satisfactory design can be obtained in a straightforward way. Theory is limited to a minimum, and used to support the practical design work. The book introduces geometrical optics, optical instruments and aberrations. It gives a description of the process of lens design and of the strategies used in this process. Half of its content is devoted to the design of sixteen types of lenses, described in detail from beginning to end. This book is different from most other books on lens design because it stresses the importance of the initial phases of the design process: (paraxial) lay-out and (thin-lens) pre-design. The argument for this change of accent is that in these phases much information can be obtained about the properties of the lens to be designed. This information can be used in later phases of the design. This makes A Course in Lens Design a useful self-study book, and a suitable basis for an intro...

  16. Gabor lens theory

    International Nuclear Information System (INIS)

    The principle of using the space charge of an electron cloud to focus ion beams was first proposed by Gabor. Electrons are to be confined radially by means of an axial magnetic field B/sub z/ and axially by means of externally applied electric fields E/sub z/. An ion beam of charge density n/sub i/ much less than n/sub e/, the electron charge density can then be focused by the radial electric field set up by the electron cloud. The case considered here is that of a hollow cylindrical conductor charged to a potential +V with grounded rings on either side to set up the axial E/sub z/ field. A solenoid wound around the central conductor supplies the B/sub z/ field. Theoretical calculations are carried out for n/sub e/ maximum as a function of B/sub z/ due to radial confinement and V due to axial confinement and the focal length of the Gabor Lens is calculated

  17. Capsule endoscopy in neoplastic diseases

    Institute of Scientific and Technical Information of China (English)

    Marco Pennazio; Emanuele Rondonotti; Roberto de Franchis

    2008-01-01

    Until recently,diagnosis and management of small-bowel tumors were delayed by the difficulty of access to the small bowel and the poor diagnostic capabilities of the available diagnostic techniques.An array of new methods has recently been developed,increasing the possibility of detecting these tumors at an earlier stage.Capsule endoscopy (CE) appears to be an ideal tool to recognize the presence of neoplastic lesions along this organ,since it is non-invasive and enables the entire small bowel to be visualized.Highquality images of the small-bowel mucosa may be captured and small and fiat lesions recognized,without exposure to radiation.Recent studies on a large population of patients undergoing CE have reported small-bowel tumor frequency only slightly above that reported in previous surgical series (range,1.6%-2.4%)and have also confirmed that the main clinical indication to CE in patients with small-bowel tumors is obscure gastrointestinal (GI) bleeding.The majority of tumors identified by CE are malignant;many were unsuspected and not found by other methods.However,it remains difficult to identify pathology and tumor type based on the lesion's endoscopic appearance.Despite its limitations,CE provides crucial information leading in most cases to changes in subsequent patient management.Whether the use of CE in combination with other new diagnostic (MRI or multidetector CT enterography) and therapeutic (Push-and-pull enteroscopy) techniques will lead to earlier diagnosis and treatment of these neoplasms,ultimately resulting in a survival advantage and in cost savings,remains to be determined through carefully-designed studies.

  18. Effect of four different intraocular lenses on posterior capsule opacification

    Institute of Scientific and Technical Information of China (English)

    Rahmi; Duman; Fatih; Karel; Pelin; ?zyol; Can; Ates

    2015-01-01

    AIM: To evaluate the impact of 4 different intraocular lenses(IOLs) on posterior capsule opacification(PCO) by comparing the neodymium: yttrium-aluminum-garnet(Nd:YAG) laser capsulotomy rates.METHODS: This retrospective study included 4970 eyes of 4013 cataract patients who underwent phacoemulsification and IOL implantation between January 2000 and January 2008 by the same surgeon at one clinic. Four different IOLs were assessed. The outcome parameter was the incidence of Nd:YAG laser posterior capsulotomies.· RESULTS: An Nd:YAG laser posterior capsulotomy was performed in 153(3.07%) of the 4970 eyes. The mean follow-up time was 84 mo for all of the IOL groups. The percentage of eyes developing PCO was significantly greater for the acrylic hydrophilic IOLs than for the hydrophobic IOLs, although eyes with acrylic hydrophilic IOLs did not require Nd:YAG laser capsulotomy as soon as eyes with acrylic hydrophobic IOLs. There was no difference between the long-term PCO rates when 1-and 3-piece acrylic hydrophobic IOLs were compared or when IOLs made of the same material but with different haptic angles were compared.· CONCLUSION: In this study, eyes with acrylic hydrophilic IOLs were more likely to develop PCO than those with acrylic hydrophobic IOLs. The lens design(1-piece versus 3-piece and varying haptic angles) did not affect the PCO rate.

  19. 3D Printed Programmable Release Capsules.

    Science.gov (United States)

    Gupta, Maneesh K; Meng, Fanben; Johnson, Blake N; Kong, Yong Lin; Tian, Limei; Yeh, Yao-Wen; Masters, Nina; Singamaneni, Srikanth; McAlpine, Michael C

    2015-08-12

    The development of methods for achieving precise spatiotemporal control over chemical and biomolecular gradients could enable significant advances in areas such as synthetic tissue engineering, biotic-abiotic interfaces, and bionanotechnology. Living organisms guide tissue development through highly orchestrated gradients of biomolecules that direct cell growth, migration, and differentiation. While numerous methods have been developed to manipulate and implement biomolecular gradients, integrating gradients into multiplexed, three-dimensional (3D) matrices remains a critical challenge. Here we present a method to 3D print stimuli-responsive core/shell capsules for programmable release of multiplexed gradients within hydrogel matrices. These capsules are composed of an aqueous core, which can be formulated to maintain the activity of payload biomolecules, and a poly(lactic-co-glycolic) acid (PLGA, an FDA approved polymer) shell. Importantly, the shell can be loaded with plasmonic gold nanorods (AuNRs), which permits selective rupturing of the capsule when irradiated with a laser wavelength specifically determined by the lengths of the nanorods. This precise control over space, time, and selectivity allows for the ability to pattern 2D and 3D multiplexed arrays of enzyme-loaded capsules along with tunable laser-triggered rupture and release of active enzymes into a hydrogel ambient. The advantages of this 3D printing-based method include (1) highly monodisperse capsules, (2) efficient encapsulation of biomolecular payloads, (3) precise spatial patterning of capsule arrays, (4) "on the fly" programmable reconfiguration of gradients, and (5) versatility for incorporation in hierarchical architectures. Indeed, 3D printing of programmable release capsules may represent a powerful new tool to enable spatiotemporal control over biomolecular gradients. PMID:26042472

  20. A medieval fallacy: the crystalline lens in the center of the eye

    Directory of Open Access Journals (Sweden)

    Leffler CT

    2016-04-01

    Full Text Available Christopher T Leffler,1 Tamer M Hadi,2 Akrithi Udupa,1 Stephen G Schwartz,3 Daniel Schwartz1 1Department of Ophthalmology, Virginia Commonwealth University, Richmond, VA, 2Graduate School of Medicine, University of Tennessee Medical Center, Knoxville, TN, 3Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA Objective: To determine whether, as most modern historians have written, ancient Greco-Roman authors believed the crystalline lens is positioned in the center of the eye. Background: Historians have written that statements about cataract couching by Celsus, or perhaps Galen of Pergamon, suggested a centrally located lens. Celsus specifically wrote that a couching needle placed intermediate between the corneal limbus and the lateral canthus enters an empty space, presumed to represent the posterior chamber. Methods: Ancient ophthalmic literature was analyzed to understand where these authors believed the crystalline lens was positioned. In order to estimate where Celsus proposed entering the eye during couching, we prospectively measured the distance from the temporal corneal limbus to the lateral canthus in 30 healthy adults. Results: Rufus of Ephesus and Galen wrote that the lens is anterior enough to contact the iris. Galen wrote that the lens equator joins other ocular structures at the corneoscleral junction. In 30 subjects, half the distance from the temporal corneal limbus to the lateral canthus was a mean of 4.5 mm (range: 3.3–5.3 mm. Descriptions of couching by Celsus and others are consistent with pars plana entry of the couching needle. Anterior angulation of the needle would permit contact of the needle with the lens. Conclusion: Ancient descriptions of anatomy and couching do not establish the microanatomic relationships of the ciliary region with any modern degree of accuracy. Nonetheless, ancient authors, such as Galen and Rufus, clearly understood that the lens is located anteriorly

  1. Uveitis-glaucoma-hyphema syndrome caused by posterior chamber intraocular lens--a rare complication in pediatric cataract surgery.

    Science.gov (United States)

    Lin, Chun-Ju; Tan, Chau-Yi; Lin, Szu-Yuan; Jou, Jieh-Ren

    2008-01-01

    We report a case of postoperative uveitis-glaucome-hyphema (UGH) syndrome following pediatric cataract surgery due to posterior chamber intraocular lens (PC-IOL). Slit-lamp examination revealed the optic of PC-IOL migrated into anterior chamber. The PC-IOL explantation was performed and ocular inflammation subsided. PMID:19230361

  2. Refraction and eye anterior segment parameters in schizophrenic patients

    Directory of Open Access Journals (Sweden)

    Tongabay Cumurcu

    2015-06-01

    Full Text Available ABSTRACT Purpose: To evaluate the difference in terms of refractive errors and anterior segment parameters between schizophrenic patients and healthy volunteers. Methods: This study compared 70 patients (48 men who were diagnosed with schizophrenia with a control group of 60 (35 men who were similar in terms of age, gender, education, and socioeconomic level. Anterior segment examination was performed using a Scheimflug system. Axial length and lens thickness (LT were measured using optic biometry. The following tests were administered to the psychiatric patient group: Brief Psychiatric Rating Scale (BPRS, Scale for the Assessment of Negative Symptoms (SANS, and Scale for the Assessment of Positive Symptoms (SAPS. Results: Mild myopia was detected in both the schizophrenic and control groups, with no statistically significant difference (p>0.005. Corneal volume (CV, anterior chamber volume (ACV, anterior chamber depth (ACD, and central corneal thickness (CCT values were lower in the schizophrenic group, and there was a statistically significant between-group difference (p=0.026, p=0.014, p=0.048, and p=0.005, respectively. LT was greater in schizophrenics, and the difference was found to be statistically significant (p=0.006. A statistically significant negative correlation was found between SAPS and cylinder values (p=0.008. The axial eye length, cylinder value, pupil diameter, mean keratometric value, and anterior chamber angle revealed no statistically significant difference between the groups (p>0.05. Conclusion: No statistically significant difference was detected in terms of refraction disorders between schizophrenics and the healthy control group, while some differences in anterior chamber parameters were present. These results demonstrate that schizophrenics may exhibit clinical and structural differences in the eye.

  3. Lubricin in human breast tissue expander capsules.

    Science.gov (United States)

    Cheriyan, Thomas; Guo, Lifei; Orgill, Dennis P; Padera, Robert F; Schmid, Thomas M; Spector, Myron

    2012-10-01

    Capsular contraction is the most common complication of breast reconstruction surgery. While presence of the contractile protein alpha smooth muscle actin (α-SMA) is considered among the causes of capsular contraction, the exact etiology and pathophysiology is not fully understood. The objective of this study was to investigate the possible role of lubricin in capsular formation and contraction by determining the presence and distribution of the lubricating protein lubricin in human breast tissue expander capsules. Related aims were to evaluate select histopathologic features of the capsules, and the percentage of cells expressing α-SMA, which reflects the myofibroblast phenotype. Capsules from tissue expanders were obtained from eight patients. Lubricin, at the tissue-implant interface, in the extracellular matrix, and in cells, and α-SMA-containing cells were evaluated immunohistochemically. The notable finding was that lubricin was identified in all tissue expander capsules: as a discrete layer at the tissue-implant interface, extracellular, and intracellular. There was a greater amount of lubricin in the extracellular matrix in the intimal-subintimal zone when compared with the tissue away from the implant. Varying degrees of synovial metaplasia were seen at the tissue-implant interface. α-SMA-containing cells were also seen in all but one patient. The findings might help us better understand factors involved in capsule formation.

  4. Carbachol as miotic agent in intra-ocular lens implant surgery

    Directory of Open Access Journals (Sweden)

    Agarwal Jitendra

    1988-01-01

    Full Text Available The intra cameral use of 0.025% carbachol as a miotic agent in anterior chamber intraocular lens im-plant surgery us reported in 15 cases. Carbachol produced prompt and effective moisis and was found to be harmless and non-irritating to the anterior chamber structures. A rebound dialatation of the pipit was noticed in the post operative period in 3 of our first 5 cases where only carbachol was used. For prolonged miosis instillation of a more powerful miotic like pilocarpine is recommended at the completion of surgery:

  5. Posterior chamber phakic intraocular lens implantation for high myopia

    Institute of Scientific and Technical Information of China (English)

    沈晔; 杜持新; 顾扬顺; 王竞

    2003-01-01

    Objective To evaluate the efficacy, safety and stability of posterior chamber phakic intraocular lens (PIOLs) implantation for the correction of high myopia.Methods Thirty-nine eyes of twenty patients with high myopia (between-11.75 and-25.75 diopters) had a posterior chamber PIOL (Staar ICL) implanted. During 6-48 months' follow-up, visual acuity, refraction, intraocular pressure (IOP), corneal reaction and space between crystal lens and intraocular lens (IOLs) were tested.Results Successful implantation was achieved in all patients. Visual acuity without correction greater than 0.5 was found in 34 eyes at 1 day and 3 months postoperatively. Thirty-five eyes maintained a low negative power of refraction (-1.42±1.32 doipters), which did not prevent the patients from most of their daily activities. During 3-48 months' follow-up, refraction was stable and no cornea edema and glaucoma was found. Two eyes of one patient had corticosteroid glaucoma and another eye showed cataractogenesis under anterior capsular membrane.Conclusion Posterior chamber PIOL implantation is predictable, safe, and effective in the correction of high myopia, and its indications should be carefully selected.

  6. Simultaneous phacoemulsification, lens implantation and endothelial keratoplasty: Triple procedure

    Directory of Open Access Journals (Sweden)

    Nikolić Ljubiša

    2011-01-01

    Full Text Available Introduction. Simultaneous Descemet stripping endothelial keratoplasty, phacoemulsification, and intraocular lens implantation are indicated in Fuchs’ dystrophy with associated cataract. Compared to the standard method of the triple procedure which includes penetrating keratoplasty, this new method has the advantages of sutureless surgery, small limbal incision, faster recovery, less surface problems, less astigmatism, stronger tensile strength and more predictable calculation of the intraocular lens power. This is the first report of such a combination of procedures in our literature. Case report. A 76-year-old woman suffered from a gradual bilateral visual loss. The best corrected visual acuity was 20/60 (right eye and finger counting at 1m (left eye. Corneal thickness was 590 μm and 603 μm, respectively. A marked cornea guttata and nuclear cataract were present in both eyes. Phacoemulsification, lens implantation, and Descemet stripping were done in the left eye. The posterior lamellar corneal graft, 8.0 mm in diameter and about 150 μm thick, was bent and inserted through the limbal incision. The air was injected into the anterior chamber to attach the graft to the recipient stroma. The cornea remained clear, and the transplant was attached during a two-year follow-up. Visual acuity was 20/40 after two months, and 20/25 after one year. Conclusion. The new technique proved itself as a good choice for the treatment of a mild Fuchs’ dystrophy associated with cataract.

  7. Anterior hip pain.

    Science.gov (United States)

    O'Kane, J W

    1999-10-15

    Anterior hip pain is a common complaint with many possible causes. Apophyseal avulsion and slipped capital femoral epiphysis should not be overlooked in adolescents. Muscle and tendon strains are common in adults. Subsequent to accurate diagnosis, strains should improve with rest and directed conservative treatment. Osteoarthritis, which is diagnosed radiographically, generally occurs in middle-aged and older adults. Arthritis in younger adults should prompt consideration of an inflammatory cause. A possible femoral neck stress fracture should be evaluated urgently to prevent the potentially significant complications associated with displacement. Patients with osteitis pubis should be educated about the natural history of the condition and should undergo physical therapy to correct abnormal pelvic mechanics. "Sports hernias," nerve entrapments and labral pathologic conditions should be considered in athletic adults with characteristic presentations and chronic symptoms. Surgical intervention may allow resumption of pain-free athletic activity. PMID:10537384

  8. Capsule endoscopy—A mechatronics perspective

    Science.gov (United States)

    Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay

    2011-03-01

    The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.

  9. Intestinal preparation prior to capsule endoscopy administration

    Institute of Scientific and Technical Information of China (English)

    Vicente Pons Beltrán; Cristina Carretero; Bego(n)a Gonzalez-Suárez; I(n)aqui Fernández-Urien; Miguel Mu(n)oz Navas

    2008-01-01

    In order to have an adequate view of the whole small intestine during capsule endoscopy,the preparation recommended consists of a clear liquid diet and an overnight fast.However,visualization of the small bowel during video capsule endoscopy can be impaired by intestinal contents.To improve mucosal visualization,some authors have evaluated different regimens of preparation.There is no consensus about the necessity of intestinal preparation for capsule endoscopy and it should be interesting to develop adequate guidelines to improve its efficacy and tolerability.Moreover,the effect of preparation type (purgative) on intestinal transit time is not clear.Since a bowel preparation cannot definitively improve its visibility (and theoretically the yield of the test),it is not routinely recommended.

  10. Video capsule endoscopy in inflammatory bowel disease

    Science.gov (United States)

    Collins, Paul D

    2016-01-01

    Video capsule endoscopy (VCE) has evolved to become an important tool for the non-invasive examination of the small bowel, which hitherto had been relatively inaccessible to direct visualisation. VCE has been shown to play a role in monitoring the activity of small bowel Crohn’s disease and can be used to assess the response to anti-inflammatory treatment in Crohn’s disease. For those patients with Crohn’s disease who have undergone an intestinal resection, VCE has been assessed as a tool to detect post-operative recurrence. VCE may also aid in the reclassification of patients with a diagnosis of Inflammatory Bowel Disease Unclassified to Crohn’s disease. The evolution of colon capsule endoscopy (CCE) has expanded the application of this technology further. The use of CCE to assess the activity of ulcerative colitis has been described. This advance in capsule technology has also fuelled interest in its potential role as a minimally invasive tool to assess the whole of GI tract opening the possibility of its use for the panenteric assessment of Crohn’s disease. VCE is a safe procedure. However, the risk of a retained capsule is higher in patients with suspected or confirmed Crohn’s disease compared with patients having VCE examination for other indications. A retained video capsule is rare after successful passage of a patency capsule which may be utilised to pre-screen patients undergoing VCE. This paper describes the use of VCE in the assessment of inflammatory bowel disease. PMID:27499830

  11. Biomarkers and special features of oxidative stress in the anterior segment of the eye linked to lens cataract and the trabecular meshwork injury in primary open-angle glaucoma: challenges of dual combination therapy with N-acetylcarnosine lubricant eye drops and oral formulation of nonhydrolyzed carnosine.

    Science.gov (United States)

    Babizhayev, Mark A

    2012-02-01

    The implication of oxidative stress associated with increased oxidant production in mammalian and human cells characterized by the release of free radicals, resulting in cellular degeneration, is involved in many ocular diseases, such as age-related macular degeneration, retinopathy of prematurity, retinal light damage, primary open-angle glaucoma (POAG), and cataract. Cataract is the leading cause of blindness, accounting for 50% of blindness worldwide. Glaucoma, the leading cause of irreversible blindness, is considered as a progressive optic neuropathy often caused by elevated intraocular pressure (IOP) consequent to abnormally high resistance to aqueous humor (AH) drainage via the trabecular meshwork (TM) and Schlemm's canal. Morphological and biochemical analyses of the TM of patients with POAG revealed the loss of cells, increased accumulation of extracellular matrix proteins (ECM), changes in the cytoskeleton, cellular senescence, and the process of subclinical inflammation. The TM is the target tissue of glaucoma in the anterior chamber, and the development and progression of glaucoma are accompanied by the accumulation of oxidative damage in this tissue. The separate studies were conducted to comparatively evaluate the sensitivity to oxidative stress and lipid peroxidation (LPO) of anterior chamber tissues including TM. Accumulation of the primary, secondary, and end products of LPO (diene and triene conjugates, Schiff's bases) was noted in the studied extracts. Significant differences in the levels of all mentioned LPO products in comparison with the control were observed. The data may be considered as an evidence of LPO participation in the destruction of the trabecule and Schlemm's canal in POAG. Treatment of TM cells with oxidative stress induced POAG-typical changes such as ECM accumulation, cell death, disarrangement of the cytoskeleton, advanced senescence, and the release of inflammatory markers. By pretreatment with antioxidants, prostaglandin

  12. Capsules with external navigation and triggered release.

    Science.gov (United States)

    Shchukin, Dmitry G; Shchukina, Elena

    2014-10-01

    Encapsulation is an important technology for pharmaceutical industry, food production, et cetera. Its current level of development requires capsule functionalization. One of the interesting ideas to provide new functionality to the microcapsule and nanocapsule is layer-by-layer deposition of functional species. This technique provides step-by-step adsorption of various species (polyelectrolytes, nanoparticles, proteins) when the layer growth is controlled by electrostatic, hydrogen bonding, hydrophobic forces and forming multilayer shells with nanometer precision. This review article introduces recent achievements of layer-by-layer technique attaining external navigation ability and release properties the capsule shell.

  13. AGE-RAGE interaction in the TGFβ2-mediated epithelial to mesenchymal transition of human lens epithelial cells.

    Science.gov (United States)

    Raghavan, Cibin T; Nagaraj, Ram H

    2016-08-01

    Basement membrane (BM) proteins accumulate chemical modifications with age. One such modification is glycation, which results in the formation of advanced glycation endproducts (AGEs). In a previous study, we reported that AGEs in the human lens capsule (BM) promote the TGFβ2-mediated epithelial-to-mesenchymal transition (EMT) of lens epithelial cells, which we proposed as a mechanism for posterior capsule opacification (PCO) or secondary cataract formation. In this study, we investigated the role of a receptor for AGEs (RAGE) in the TGFβ2-mediated EMT in a human lens epithelial cell line (FHL124). RAGE was present in FHL124 cells, and its levels were unaltered in cells cultured on either native or AGE-modified BM or upon treatment with TGFβ2. RAGE overexpression significantly enhanced the TGFβ2-mediated EMT responses in cells cultured on AGE-modified BM compared with the unmodified matrix. In contrast, treatment of cells with a RAGE antibody or EN-RAGE (an endogenous ligand for RAGE) resulted in a significant reduction in the TGFβ2-mediated EMT response. This was accompanied by a reduction in TGFβ2-mediated Smad signaling and ROS generation. These results imply that the interaction of matrix AGEs with RAGE plays a role in the TGFβ2-mediated EMT of lens epithelial cells and suggest that the blockade of RAGE could be a strategy to prevent PCO and other age-associated fibrosis. PMID:27263094

  14. Planar immersion lens with metasurfaces

    CERN Document Server

    Ho, John S; Tanabe, Yuji; Yeh, Alexander J; Fan, Shanhui; Poon, Ada S Y

    2015-01-01

    The solid immersion lens is a powerful optical tool that allows light entering material from air or vacuum to focus to a spot much smaller than the free-space wavelength. Conventionally, however, they rely on semispherical topographies and are non-planar and bulky, which limits their integration in many applications. Recently, there has been considerable interest in using planar structures, referred to as metasurfaces, to construct flat optical components for manipulating light in unusual ways. Here, we propose and demonstrate the concept of a planar immersion lens based on metasurfaces. The resulting planar device, when placed near an interface between air and dielectric material, can focus electromagnetic radiation incident from air to a spot in material smaller than the free-space wavelength. As an experimental demonstration, we fabricate an ultrathin and flexible microwave lens and further show that it achieves wireless energy transfer in material mimicking biological tissue.

  15. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  16. New Management of Malignant Glaucoma by Phacoemulsification with Posterior Chamber Foldable Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    GeJian; GuoY

    1999-01-01

    Objective:To investigate the feasibility of phacoemulsification with posterior chamber foldable intraocular lens implantation in the management of malignant glaucoma. Patients and Methods:Fourteen patients with malignant glaucoma diagnosed in the Department of Glaucoma were enrolled in the study.12 patients developed malignant glaucoma after filtration surgery.1 developed after peripheral iridectomy.1 patient developed malignant glaucoma without any clear cause.Cataract phacoemulsification was performed.Posterior chamber intraocular foldable lens was implanted in 10 cases of patients.Results:All 14 patients were cured wiht normal intraocular pressure,normal anterior chamber depth and increased visual acuity.Conclusion:Phacoemulsification with posterior chamber foldable intraocular lens implantation is a good alternative in treating malignant glaucoma.

  17. IMPLANTABLE COLLAMER LENS IMPLANTATION AND IRIS CERCLAGE FOR THE TREATMENT OF URRETS-ZAVALIA SYNDROME

    Directory of Open Access Journals (Sweden)

    Arnaldo D Santos

    2013-10-01

    Full Text Available A 27-year-old woman with bilateral high myopia had anterior chamber iris-claw phakic IOL implantation in her left eye (LE under local anesthesia, without intraoperative complications. The preoperative slitlamp examination was normal and she had no past medical history. On the second day post-operatory, she developed fixed dilated mydriasis and one month later we documented IOL subluxation. There had been no history of intra-ocular hypertension and no mydriatic drops were used. Diagnosis of Urrets-Zavalia syndrome was established. We removed the IOL and observed for six months after adapting coloured contact lens. During this time she complained about glare, photophobia and developed contact lens intolerance. We decided to implant a posterior chamber Implantable Collamer Lens (ICL and to perform iris cerclage in the LE, with good aesthetic and refractive outcome. Posterior chamber ICL implantation with iris cerclage seems to be a simple and effective approach to this situation.

  18. Liquid crystal Fresnel lens display

    Science.gov (United States)

    Wang, Xiao-Qian; Abhishek Kumar, Srivastava; Alwin Tam, Ming-Wai; Zheng, Zhi-Gang; Shen, Dong; Vladimir, Chigrinov G.; Kwok, Hoi-Sing

    2016-09-01

    A novel see-through display with a liquid crystal lens array was proposed. A liquid crystal Fresnel lens display (LCFLD) with a holographic screen was demonstrated. The proposed display system has high efficiency, simple fabrication, and low manufacturing cost due to the absence of a polarizer and color filter. Project supported by Partner State Key Laboratory on Advanced Displays and Optoelectronics Technologies HKUST, China, the National Natural Science Foundation of China (Grant Nos. 61435008 and 61575063), and the Fundamental Research Funds for the Central Universities, China (Grant No. WM1514036).

  19. Computer-aided lens assembly.

    Science.gov (United States)

    Tomlinson, Richard; Alcock, Rob; Petzing, Jon; Coupland, Jeremy

    2004-01-20

    We propose a computer-aided method of lens manufacture that allows assembly, adjustment, and test phases to be run concurrently until an acceptable level of optical performance is reached. Misalignment of elements within a compound lens is determined by a comparison of the results of physical ray tracing by use of an array of Gaussian laser beams with numerically obtained geometric ray traces. An estimate of misalignment errors is made, and individual elements are adjusted in an iterative manner until performance criteria are achieved. The method is illustrated for the alignment of an air-spaced doublet. PMID:14765916

  20. Capsule endoscopy: Current status in obscure gastrointestinal bleeding

    Institute of Scientific and Technical Information of China (English)

    R Gupta; Nageshwar Duvvuru Reddy

    2007-01-01

    Capsule endoscopy (CE) is a safe, non invasive diagnostic modality for the evaluation of small bowel lesions. Obscure gastrointestinal bleeding (OGIB) is one of the most important indications of capsule endoscopy.Capsule endoscopy has a very high diagnostic yield especially if the bleeding is ongoing. This technique appears to be superior to other techniques for the detection of suspected lesions and the source of bleeding. Capsule endoscopy has been shown to change the outcome in patients with obscure gastrointestinal (GI)bleed.

  1. ADHESIVE CAPSULITIS: USE THE EVIDENCE TO INTEGRATE YOUR INTERVENTIONS

    OpenAIRE

    Page, Phil; Labbe, Andre

    2010-01-01

    Frozen shoulder syndrome, clinically known as adhesive capsulitis, is a painful and debilitating condition affecting up to 5% of the population. Adhesive capsulitis is considered fibrosis of the glenohumeral joint capsule with a chronic inflammatory response. Patients experience pain, limited range of motion, and disability generally lasting anywhere from 1 to 24 months. The purpose of this clinical suggestion is to review the pathophysiolgy of adhesive capsulitis and discuss physical therapy...

  2. 21 CFR 520.2345a - Tetracycline hydrochloride capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Tetracycline hydrochloride capsules. 520.2345a... Tetracycline hydrochloride capsules. (a) Specifications. Each capsule contains 50, 100, 125, 250, or 500 milligrams (mg) tetracycline hydrochloride. (b) Sponsor. See sponsors in § 510.600(c) of this chapter for...

  3. 21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin sodium monohydrate equivalent to 50, 100, 200, or 500 milligrams of dicloxacillin. (b) Sponsor. See No. 000856...

  4. 21 CFR 872.3110 - Dental amalgam capsule.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with...

  5. The migration of human lens epithelial cells induced by UV-irradiation in vitro

    Institute of Scientific and Technical Information of China (English)

    Jin Yao; Guoxing Yuan; Yuan Liu; Yi Shen; Qin Jiang

    2008-01-01

    Objective: Ultraviolet (UV) radiation is one of the important cataract risk factors. However, the pathogenesis is still poorly understood.The migration of human lens epithelial cells(HLECs) plays a crucial role in the remodeling of lens capsule and cataract formation. The purpose of this study is to investigate the mechanism of UV inducing cataractogenesis. Methods:The toxicity of UV-irradiation on HLECs was assessed by Methyl thiazolyl tetrazolium(MTT) assay. The activity of matrix metalloproteinase-2(MMP-2) was observed by Gelatin zymography. The migration of HLECs was examined by Cell Track Motility. Results:UV-irradiation does great harm to HLECs, and may induce apoptosis in the cells when UV higher than 15 mj/cm2. UV significantly increased MMP-2 activity in a timedependent manner. In addition, the irradiation could induce the migration of HLECs. Conclusion:UV-irradiation could induce the migration of HLECs by increasing the activity of MMP-2.

  6. SimpLens: Interactive gravitational lensing simulator

    Science.gov (United States)

    Saha, Prasenjit; Williams, Liliya L. R.

    2016-06-01

    SimpLens illustrates some of the theoretical ideas important in gravitational lensing in an interactive way. After setting parameters for elliptical mass distribution and external mass, SimpLens displays the mass profile and source position, the lens potential and image locations, and indicate the image magnifications and contours of virtual light-travel time. A lens profile can be made shallower or steeper with little change in the image positions and with only total magnification affected.

  7. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... Let’s go. Great. Well, thanks, Roger, for that introduction, and welcome everyone to the Mount Carmel New ... just good tools. So I would say the learning is about the same. Well ... ahead while I got the machine in there, and pre-treat that posterior capsule ...

  8. Effects of age on ocular anterior segment dimensions measured by optical coherence tomography

    Institute of Scientific and Technical Information of China (English)

    QIN Bing; ZHOU Xing-tao; HUANG David; CHU Ren-yuan

    2011-01-01

    Background Older subjects tend to have smaller ocular anterior segment. The present study aimed to measure anterior segment dimensions with optical coherence tomography (OCT) and quantitatively assess the effect of age and other factors.Results Sixty-six eyes of 33 normal subjects (aged 22-65 years, 19 Asians, 14 Caucasians) were enrolled. For every 1 year of age, corneal diameter was 0.033 mm narrower (P <0.01), anterior chamber width was 0.031 mm narrower (P <0.01), corneal vault was 0.016 mm lower (P<0.01), and anterior chamber depth was 0.025 mm lower (P<0.01). Asian eyes had smaller corneal diameter (P=0.035) and anterior chamber width (P=0.015) compared with those of Caucasian eyes. Body height showed positive correlation with corneal diameter (0.039 mm per centimeter of height, P <0.01) and corneal vault (0.024 mm per centimetre of height, P <0.01). Gender did not have an independent effect on anterior segment dimensions.Conclusions Anterior segment dimensions were smaller in older subjects. Age-related changes may affect the tolerability of long-term implants such as phakic intraocular lens.

  9. [Numerical Simulation of Heat Transfer in the Human Anterior Chamber at Different Corneal Temperatures].

    Science.gov (United States)

    Guo, Jingmin; Zhang, Hong; Wang, Junming

    2015-12-01

    A three-dimensional (3D) model of human anterior chamber is reconstructed to explore the effect of different corneal temperatures on the heat transfer in the chamber. Based on the optical coherence tomography imaging of the volunteers with normal anterior chamber, a 3D anterior chamber model was reconstructed by the method of UG parametric design. Numerical simulation of heat transfer and aqueous humor flow in the whole anterior chamber were analyzed by the finite volume methods at different corneal temperatures. The results showed that different corneal temperatures had obvious influence on the temperature distribution and the aqueous flow in the anterior chamber. The temperature distribution is linear and axial symmetrical around the pupillary axis. As the temperature difference increases, the symmetry becomes poorer. Aqueous floated along the warm side and sank along the cool side which forms a vortexing flow. Its velocity increased with the addition of temperature difference. Heat fluxes of cornea, lens and iris were mainly affected by the aqueous velocity. The higher the velocity, the bigger more absolute value of the above-mentioned heat fluxes became. It is practicable to perform the numerical simulation of anterior chamber by the optical coherence tomography imaging. The results are useful for studying the important effect of corneal temperature on the heat transfer and aqueous humor dynamics in the anterior chamber.

  10. Design of Endoscopic Capsule With Multiple Cameras.

    Science.gov (United States)

    Gu, Yingke; Xie, Xiang; Li, Guolin; Sun, Tianjia; Wang, Dan; Yin, Zheng; Zhang, Pengfei; Wang, Zhihua

    2015-08-01

    In order to reduce the miss rate of the wireless capsule endoscopy, in this paper, we propose a new system of the endoscopic capsule with multiple cameras. A master-slave architecture, including an efficient bus architecture and a four level clock management architecture, is applied for the Multiple Cameras Endoscopic Capsule (MCEC). For covering more area of the gastrointestinal tract wall with low power, multiple cameras with a smart image capture strategy, including movement sensitive control and camera selection, are used in the MCEC. To reduce the data transfer bandwidth and power consumption to prolong the MCEC's working life, a low complexity image compressor with PSNR 40.7 dB and compression rate 86% is implemented. A chipset is designed and implemented for the MCEC and a six cameras endoscopic capsule prototype is implemented by using the chipset. With the smart image capture strategy, the coverage rate of the MCEC prototype can achieve 98% and its power consumption is only about 7.1 mW. PMID:25376042

  11. Student Mobility. Information Capsule. Volume 0608

    Science.gov (United States)

    Blazer, Christie

    2007-01-01

    Mobility, rather than stability, has become the norm for students in schools across the United States. The student mobility rate is now higher in the United States than in any other industrialized country. This Information Capsule discusses the reasons for student mobility and the characteristics of highly mobile students and families. Research…

  12. Intrauterine fertilization capsules--a clinical trial

    DEFF Research Database (Denmark)

    Lenz, S; Lindenberg, S; Sundberg, K;

    1991-01-01

    Treatment of 26 women with tubal infertility was attempted using intrauterine capsules loaded with oocytes and spermatozoa. The stimulation protocol was as used for in vitro fertilization and embryo transfer and consisted of short-term use of Buserelin, human menopausal gonadotropin, and human ch...

  13. Evaluation of ultrasonic biomicroscopy results in anterior eye segment before and after cataract surgery

    OpenAIRE

    Ciftci S.; Simsek A.

    2012-01-01

    Ali Simsek,1 Süleyman Ciftci21Department of Ophthalmology, Faculty of Medicine, Adiyaman University, Adiyaman, Turkey; 2Department of Ophthalmology, Diyarbakir Training and Research Hospital, Diyarbakir, TurkeyBackground: The aim of this study was to assess the value of ultrasonic biomicroscopy in reporting decreases in intraocular pressure resulting from changes in anterior chamber depth and angle after phacoemulsification and intracapsular lens implantation in patients with catarac...

  14. A broadband transformation-optics metasurface lens

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Xiang; Xiang Jiang, Wei; Feng Ma, Hui; Jun Cui, Tie, E-mail: tjcui@seu.edu.cn [State Key Laboratory of Millimeter Waves, School of Information Science and Engineering, Southeast University, Nanjing 210096 (China)

    2014-04-14

    We present a transformational metasurface Luneburg lens based on the quasi-conformal mapping method, which has weakly anisotropic constitutive parameters. We design the metasurface lens using inhomogeneous artificial structures to realize the required surface refractive indexes. The transformational metasurface Luneburg lens is fabricated and the measurement results demonstrate very good performance in controlling the radiated surface waves.

  15. 21 CFR 886.3600 - Intraocular lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens. 886.3600 Section 886.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials...

  16. Ocular Toxicity after High-Dose Cefuroxime Injection into the Anterior Chamber

    Directory of Open Access Journals (Sweden)

    Harun Çakmak

    2016-08-01

    Full Text Available Cephalosporins are beta-lactam antibiotics and, like penicillin derivatives, they show bacteriostatic effect by disrupting bacterial cell wall synthesis. Cefuroxime is a second generation cephalosporin and the use of intracameral cefuroxime after cataract surgery has been widely used in the endophthalmitis prophylaxis. A 78-year-old male patient was operated for cataracts in both eyes about 8 years ago. Ocular trauma has occurred in the left eye nine months ago. Vitrectomy surgery combined with intraocular lens extraction was performed and the patient was left aphakic. Secondary intraocular lens implantation was performed. In this paper, we present postoperative ocular findings in a patient who was given cefuroxime into the anterior chamber 2.5 times higher than the recommended dose (25 mg/ml after secondary intraocular lens implantation.

  17. Professoren og Ålen

    DEFF Research Database (Denmark)

    Poulsen, Bo

    2016-01-01

    Biolog og havforsker Johannes Schmidt regnes for at være Danmarks mest betydningsfulde havforsker gennem tiderne. Hans mange forskningsbaserede jordomsejlinger bragte ham til eksotiske egne og til opdagelsen af adskillige nye dyrearter. Dog blev særligt ålen og dens gydepladser et hovedfokus...

  18. Outcomes of Lensectomy in Hereditary Lens Subluxation

    Directory of Open Access Journals (Sweden)

    Mohammad-Hossein Dehghan

    2008-12-01

    Full Text Available

    PURPOSE: To evaluate the results of pars plana lensectomy in patients with hereditary lens subluxation. METHOD: Hospital records of patients with hereditary lens subluxation who had undergone pars plana lensectomy at Labbafinejad Medical Center, Tehran-Iran from 1996 to 2003 were reviewed. Patients with more than 6 months of follow up were included. Underlying disorders, best corrected visual acuity (BCVA before and after surgery, intraocular pressure (IOP, postoperative refraction and complications were evaluated. RESULTS: Overall, records of 87 eyes of 49 patients including 27 male and 22 female subjects were reviewed. Mean follow up duration was 20±18 months. Underlying disorders leading to lens subluxation included Marfan syndrome (79.5%, Weill-Marchesani syndrome (8.2%, simple ectopia lentis (8.2%, and homocystinuria (4.1%. The most common indication for surgery was non-correctable refractive error (92.1%. Mean BCVA was 1.13 LogMAR (20/250 preoperatively, which improved to 0.26 LogMAR (20/30-20/40 postoperatively (P < 0.001. BCVA better than 20/40 was achieved in 82.8% of cases after surgery. Angle-supported anterior chamber intraocular lens (ACIOL was implanted in

  19. Expression of P53 during Lens Epithelial Cell Apoptosis Induced by Ultraviolet

    Institute of Scientific and Technical Information of China (English)

    SUN; Xufang; ZOU; Weiyu; ZHAO; Changsong

    2001-01-01

    The apoptosis of lens epithelial cells (LECs) induced by ultraviolet and the expression of P53 were investigated. Wistar rats received 100 mW/m2 ultraviolet irradiation (UVR) (λ=280 nm-315 nm) for 15 min. One, 6, 24 h after irradiation the lens capsules were dissected. The percentages of apoptotic cells were evaluated by the TdT-dUTP terminal nick-end labeling (TUNEL) technique and the expression of P53 was detected by using immunohistochemical assay. The results showed that the percentages of TUNEL-positive nuclei at 24 h after irradiation was significantly higher than in the control group and those 1 h, 6 h after irradiation. The percentages of P53-positive cells at 6 h,24 h after irradiation were significantly higher than in the control group and those 1 h after irradiation. It was concluded that UVR could induce the apoptosis of lens epithelial cell. The expression of P53 might be responsible for the apoptosis of lens epithelial cells.

  20. Radiation damage of the lens

    International Nuclear Information System (INIS)

    Explained is the cataract as the lens is one of the most sensitive tissues to radiation, for considering the possible ophthalmological radiation disorder by the Fukushima Nuclear Power Plant Accident (2011). Radiation cataract is observed at 1-2 years after acute high dose exposure, but at low dose, it appears as the late effect. In fact, the disease related to exposure is found in as many as 25% of Chernobyl workers at >10 years post its Accident. Pathologic feature of radiation cataract has been thought to be the posterior subcapsular type. However, the cortical type is shown to be also noted by recent findings in the Chernobyl Accident, in the lens 30-45 years after radiotherapy of infants for dermovascular angioma, in astronaut, and in Hiroshima A-bomb survivors. Acute exposure to 0.5-1.5 Gy results in lens opacity and at >5 Gy, cataract with visual dysfunction. Higher cataract prevalence is recently reported seen in the therapeutic cardiac fluoroscopy where the medians of accumulated doses are 6.0 Sv in doctors and 1.5 Sv in nurses and radiologists. Astronauts exposed at >8 mSv have higher prevalence. Animal experiments have shown that the lens sensitivity to radiation depends on the age. Clinical experience of radiotherapy of the angioma above has suggested the higher sensitivity in young generation, which is supported by the fact that, among 114 inhabitants of 60Co-contaminated building, the dose effect is observable in 61 inhabitants of the age <20 y alone. linear threshold theory (LNT) hypothesis cannot be excluded by above evidences and there is conceivably no (or extremely low) threshold for cataract. The younger the age of exposure, the higher the risk of cataract, and thereby the lens in young generation should be carefully followed-up in Fukushima. (T.T.)

  1. Symptomatic Patency Capsule Retention in Suspected Crohn's Disease

    DEFF Research Database (Denmark)

    Rasmussen, Bjørn; Nathan, Torben; Jensen, Michael Dam

    2016-01-01

    The main limitation of capsule endoscopy is the risk of capsule retention. In patients with suspected Crohn's disease, however, this complication is rare, and if a small bowel stenosis is not reliably excluded, small bowel patency can be confirmed with the Pillcam patency capsule. We present two...... patients examined for suspected Crohn's disease who experienced significant symptoms from a retained patency capsule. Both patients had Crohn's disease located in the terminal ileum. In one patient, the patency capsule caused abdominal pain and vomiting and was visualized at magnetic resonance enterography...

  2. Lactate Dehydrogenase Isoenzyme of Lens in Fetus

    Institute of Scientific and Technical Information of China (English)

    Kexi Ding; Yasong Zhang

    2002-01-01

    Purpose: The LDH isoenzyme patterns were evaluated in lens of fetus to study the metabolism in human lenses.Methods: LDH isoenzyme electrophoresis was performed in 15 lenses of human fetus aged from 4~6 months.Results: There are 5 bands of LDH in fetus lens. LDH4 lever is the highest, and LDH1 is the lowest, especially in the cortex of lens. LDH1 is higher in lens of 4 months of age than in that of 5 and 6 months of age.Conclusions: LDH isoenzyme in lens of fetus shows mainly anaerobic metabolism in development, but there is also aerobic metabolism, especially in younger fetus.

  3. Modern lens antennas for communications engineering

    CERN Document Server

    Thornton, John

    2012-01-01

    The aim of this book is to present the modern design principles and analysis of lens antennas. It gives graduates and RF/Microwave professionals the design insights in order to make full use of lens antennas.  Why do we want to write a book in lens antennas? Because this topic has not been thoroughly publicized, its importance is underestimated. As antennas play a key role in communication systems, recent development in wireless communications would indeed benefit from the characteristics of lens antennas: low profile, and low cost etc.  The major advantages of lens antennas are na

  4. Multidisciplinary management of anterior diastemata

    DEFF Research Database (Denmark)

    Furuse, Adilson Yoshio; Herkrath, Fernando José; Franco, Eduardo Jacomino;

    2007-01-01

    the aesthetic results when orthodontic therapy itself is not feasible. This article presents integrated orthodonticrestorative solutions of anterior diastemata, associated with the conditioning of the gingival tissue with composite resin, and discusses the most relevant aspects related to their etiology...

  5. Anterior approach for knee arthrography

    International Nuclear Information System (INIS)

    Objective. To develop a new method of magnetic resonance arthrography (MRA) of the knee using an anterior approach analogous to the portals used for knee arthroscopy.Design. An anterior approach to the knee joint was devised mimicking anterior portals used for knee arthroscopy. Seven patients scheduled for routine knee MRA were placed in a decubitus position and under fluoroscopic guidance a needle was advanced from a position adjacent to the patellar tendon into the knee joint. After confirmation of the needle tip location, a dilute gadolinium solution was injected.Results and conclusion. All the arthrograms were technically successful. The anterior approach to knee MRA has greater technical ease than the traditional approach with little patient discomfort. (orig.)

  6. Anterior Approach Total Hip Replacement

    Medline Plus

    Full Text Available ... Taperloc Microplasty stem and E-poly antioxidant-infused technology during a hip replacement through the anterior supine ... renewed interest at this time due to several advantages that it brings. The approach that is performed ...

  7. Primary culture and growth characteristics of four different species of lens epithelial cells%四种不同种属晶状体上皮细胞的原代培养及生长特性

    Institute of Scientific and Technical Information of China (English)

    冀立霞; 李彩娜; 刘泉; 环奕; 刘率男; 申竹芳

    2015-01-01

    目的::探索大鼠、兔、犬及人四种不同种属晶状体上皮细胞( lens epithelial cells, LECs)的原代培养条件,并观察其生长特性。方法:采用不同方法取出四种晶状体囊或前囊组织,改良组织块法进行原代培养,并在倒置显微镜下观察四种LECs的形态学特征及变化。结果:大鼠、兔、犬及人四种LECs均可采用改良组织块贴壁法进行原代培养。随着种属级别的升高,LECs贴壁能力逐渐增强,细胞由不规则的多角形向卵圆形发展、胞核渐渐圆润、胞浆越来越丰富,经多次传代后四种LECs均有向纤维化发展的趋势。结论:成功改良了大鼠、兔、犬及人 LECs 的原代培养方法,在细胞及分子水平为白内障及其相关领域的研究提供了技术支撑。%AlM:To explore the primary culture conditions for four kinds of lens epithelial cells ( LECs) of rat, rabbit, dog, and human, and measure their growth characteristics.METHODS:The lens capsule or anterior capsular tissue of rat, rabbit, dog and patient were removed by different methods, and they were cut into tiny pieces for primary culture by modified tissue adherent method. The morphological features of four kinds of LECs were observed under an inverted microscope.RESULTS: Four kinds of LECs of rat, rabbit, dog and human could be cultured primarily by tissue adherent method. With the evolution of tissue source, the adherent capacity of LECs gradually strengthened, cells form were changed from irregular polygon to oval, nucleus rounded and cytoplasm enriched gradually. Four kinds of LECs had fibrotic changes after several passages.CONCLUSlON: LECs of rat, rabbit, dog and human can be primarily cultured. This method lays the foundation for the mechanism research of caratact and related fields on the cellular and molecular levels.

  8. Update on anterior ankle impingement

    OpenAIRE

    Vaseenon, Tanawat; Amendola, Annunziato

    2012-01-01

    Anterior ankle impingement results from an impingement of the ankle joint by a soft tissue or osteophyte formation at the anterior aspect of the distal tibia and talar neck. It often occurs secondary to direct trauma (impaction force) or repetitive ankle dorsiflexion (repetitive impaction and traction force). Chronic ankle pain, swelling, and limitation of ankle dorsiflexion are common complaints. Imaging is valuable for diagnosis of the bony impingement but not for the soft tissue impingemen...

  9. Contact lens surface by electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Jung Hyuck [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin [Dongshin Univ., Naju (Korea, Republic of)

    2011-07-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility.

  10. Conjunctival impression cytology in contact lens wearers.

    Directory of Open Access Journals (Sweden)

    Simon Priya

    2002-01-01

    Full Text Available PURPOSE: To evaluate the cytological changes in conjunctiva following regular contact lens wear and to determine the correlation, if any, between severity of cytological alteration and symptoms related to contact lens wear. METHODS: One hundred eyes (50 normal asymptomatic subjects who served as a control group were studied by conjunctival impression cytology (CIC. These subjects were fitted with rigid gas permeable (RGP or soft contact lenses and were followed up at the end of 3 and 6 months. At each follow-up visit the CIC was repeated. A filter paper with the impression specimen was stained with periodic acid schiff (PAS and haematoxylin stain to study goblet cell loss. Papanicolaou stain was done to study squamous metaplasia. The cytological changes were graded using the system described by Natadisastra et al. RESULTS: Severity of cytological changes increased with the duration of contact lens wear (P = 0.00001. At the end of 6 months, 60% of symptomatic eyes wearing soft contact lens and RGP lens showed abnormal CIC changes. None of the asymptomatic RGP contact lens wearing eyes showed abnormal CIC changes whereas 33.4% of the asymptomatic soft contact lens wearing eyes showed abnormal CIC changes (P = 0.033. Epithelial changes occurred within 3-6 months of contact lens fitting. CONCLUSION: Severity of cytological changes increased with duration of lens wear (P = 0.00001. Prevalence and severity of cytological alteration is more in symptomatic contact lens wearers. Soft contact lens wearers although asymptomatic showed severe CIC changes.

  11. Anterior chamber depth during hemodialysis

    Directory of Open Access Journals (Sweden)

    Gracitelli CPB

    2013-08-01

    Full Text Available Carolina Pelegrini Barbosa Gracitelli,1 Francisco Rosa Stefanini,1 Fernando Penha,1 Miguel Ângelo Góes,2 Sérgio Antonio Draibe,2 Maria Eugênia Canziani,2 Augusto Paranhos Junior1 1Ophthalmology Department, 2Division of Nephrology, Federal University of São Paulo – UNIFESP, São Paulo, Brazil Background: Exacerbation of chronic glaucoma or acute glaucoma is occasionally observed in patients undergoing hemodialysis (HD because of anterior chamber depth changes during this therapy. Purpose: To evaluate anterior chamber depth and axial length in patients during HD sessions. Methods: A total of 67 eyes of 35 patients were prospectively enrolled. Axial length and anterior chamber depth were measured using ultrasonic biometry, and these measures were evaluated at three different times during HD sessions. Body weight and blood pressure pre- and post-HD were also measured. Results: There was no difference in the axial length between the three measurements (P = 0.241. We observed a significantly decreased anterior chamber depth (P = 0.002 during HD sessions. Conclusion: Our results support the idea that there is a change in anterior chamber depth in HD sessions. Keywords: anterior chamber, hemodialysis, axial length, acute angle-closure glaucoma

  12. A capacitor-based sensor and a contact lens sensing system for intraocular pressure monitoring

    Science.gov (United States)

    Chiou, Jin-Chern; Huang, Yu-Chieh; Yeh, Guan-Ting

    2016-01-01

    This study proposes a capacitor-based sensor on a soft contact lens for the measurement of intraocular pressure (IOP). The sensor was designed and fabricated via microelectromechanical system fabrication technologies. The soft contact lens is designed to be worn on a cornea such that the curvature of the contact lens corresponds substantially to that of the cornea. In addition, the contact lens was fabricated via a cast-molding method using poly-2-hydroxyethyl methacrylate to achieve a lens with high oxygen permeability, which can be worn comfortably for a long time. An IOP sensor prototype was implemented, which exhibited 1.2239 pF mmHg-1 (13,171 ppm mmHg-1) sensitivity during measurements of an artificial anterior chamber at pressures between 18 and 30 mmHg. The results indicate that the developed capacitor-based IOP sensor exhibited high stability and reproducibility in a series of measurements performed under various pressures. The capacitance of the proposed IOP sensor can successfully be converted into a digital value via a capacitor-to-digital converter and be transmitted via a commercial wireless telemetry system in this study.

  13. A case of iridoschisis associated with lens displacement into the vitreous cavity

    Directory of Open Access Journals (Sweden)

    Tetsuya Mutoh

    2010-05-01

    Full Text Available Tetsuya Mutoh1, Yukihiro Matsumoto1, Makoto Chikuda11Department of Ophthalmology, Dokkyo Medical University Koshigaya Hospital, Saitama, JapanAbstract: We report the case of a 67-year-old woman with a lens that was displaced into the vitreous cavity in one eye and ipsilateral iridoschisis. She was free from a history of ocular trauma or of heritable ocular disease. Her best-corrected visual acuity was 1.2 bilaterally and right eye showed signs of iridoschisis. The corneal endothelial cell density decreased to 1,263 cells/mm2 in the right eye preoperatively. We speculated that iris tissue flowing in the anterior chamber might have intermittently touched the corneal endothelium. 25-gauge pars plana vitrectomy and lens removal were performed immediately. Free-floating iris tissue was cut during surgery with care not to injure the corneal endothelial cells. The postoperative progress was satisfactory and scleral fixation of an intraocular lens is planned. Iridoschisis is an uncommon cause of lens displacement into the vitreous cavity.Keywords: lens displacement, vitreous cavity, iridoschisis, corneal endothelial cell density, free-floating iris tissue

  14. Method and apparatus for removing cataractous lens tissue by laser radiation

    International Nuclear Information System (INIS)

    The invention under discussion contemplates apparatus and technique for surgically non-invasive surgery to remove cateracted-lens tissue, enabling the beam output of a laser to be focused from a convergentray bundle to a focal spot of maximum power density at the anterior surface of a cataracted lens and which scans the focal spot over a predetermined area or areas of the cataracted lens. The beam is a focal and therefore diffuse as it enters the eye through the cornea, and it is also diffuse (being divergent) in the controllably unlikely event that the laser energy pases through an opening it has created in the cataracted lens; the diffusion assures against damage to either or both of the cornea and the retina, for power levels sufficient to achieve ablative photodecomposition and/or thermal decomposition and/or photofragmentation and/or photoemulsification of the cataracted-lens tissue. Various features are disclosed for assuring safety and uniformity in the removal of involved tissue

  15. A case of Alagille syndrome complicated by intraocular lens subluxation and rhegmatogenous retinal detachment

    Directory of Open Access Journals (Sweden)

    Fukumoto M

    2013-07-01

    Full Text Available Masanori Fukumoto, Tsunehiko Ikeda, Tetsuya Sugiyama, Mari Ueki, Takaki Sato, Eisuke Ishizaki Department of Ophthalmology, Osaka Medical College, Takatsuki City, Japan Abstract: This case report describes a case of Alagille syndrome with developing intraocular lens subluxation and rhegmatogenous retinal detachment 4 years after cataract surgery. A 15-year-old female patient with Alagille syndrome-associated cataracts in both eyes underwent phacoemulsification aspiration and intraocular lens implantation. Four years postoperative, intraocular lens subluxation developed in her left eye. For treatment, extraction of the dislocated intraocular lens, anterior vitrectomy, and intraocular lens fixation was performed. Three weeks later, the patient developed rhegmatogenous retinal detachment, which was well-treated by pars plana vitrectomy. Cataract surgery needs to be performed carefully in patients with Alagille syndrome due to the weakness of the zonule of Zinn. Careful postoperative observation is necessary for patients with Alagille syndrome who have undergone intraocular surgery in order to facilitate early detection of a possible rhegmatogenous retinal detachment. Keywords: Alagille syndrome, cataract, retina, surgery

  16. Microscopic analysis of an opacified OFT CRYL® hydrophilic acrylic intraocular lens.

    Science.gov (United States)

    Ventura, Bruna Vieira; MacLean, Kyle Douglas; Lira, Wagner; Oliveira, Daniele Mendes de; Ventura, Camila Vieira; Werner, Liliana

    2016-01-01

    A 51-year-old patient underwent posterior vitrectomy with perfluoropropane gas injection, phacoemulsification, and implantation of an Oft Cryl® hydrophilic acrylic intraocular lens (IOL) because of traumatic retinal detachment and cataract in the right eye. On the first postoperative day, gas was filling the anterior chamber because of patient's non-compliance in terms of head positioning, and was reabsorbed within one week. Eight months later, the patient returned complaining of a significant decrease in vision. IOL opacification was noticed by slit-lamp examination. The lens was explanted to undergo gross and light microscopic analysis. The lens was also stained with the alizarin red method for calcium identification. Light microscopic analysis confirmed the presence of granular deposits, densely distributed in an overall circular pattern in the central part of the lens optic. The granules stained positive for calcium. This is the first case of the opacification of this type of hydrophilic lens. Surgeons should be aware of this potential postoperative complication, and the use of hydrophilic IOLs should be avoided in procedures involving intracameral gas because of the risk of IOL opacification.

  17. Automated detection of inflammatory cells in whole anterior chamber of a uveitis mouse from swept-source optical coherence tomography images

    Science.gov (United States)

    Choi, Woo June; Pepple, Kathryn L.; Wang, Ruikang K.

    2016-03-01

    Cell grading in a rodent anterior chamber is essential for anterior inflammation evaluation in preclinical vision research. This paper describes a computerized method for detection and counting of the anterior chamber cells from swept-source optical coherence tomography (SS-OCT) images of a experimental rodent model of uveitis. The volumetric anterior segment OCT data is obtained from 100 kHz SS-OCT imaging of mouse eye in vivo. For the OCT cross-sections, each OCT structural image is de-speckled and binarized. After removal of cornea, iris, and crystalline lens structures connected to the binary image border, an area thresholding is then employed for each labeled region to isolate only celllike objects in the anterior chamber, followed by roundness estimation of the objects to identify potential cell candidates in the data. Eventually, the cell candidates are counted and graded as total number of cells in the anterior chamber.

  18. Capsule- and disk-filter procedure

    Science.gov (United States)

    Skrobialowski, Stanley C.

    2016-01-01

    Capsule and disk filters are disposable, self-contained units composed of a pleated or woven filter medium encased in a polypropylene or other plastic housing that can be connected inline to a sample-delivery system (such as a submersible or peristaltic pump) that generates sufficient pressure (positive or negative) to force water through the filter. Filter media are available in several pore sizes, but 0.45 µm is the pore size used routinely for most studies at this time. Capsule or disk filters (table 5.2.1.A.1) are required routinely for most studies when filtering samples for trace-element analyses and are recommended when filtering samples for major-ion or other inorganic-constituent analyses.

  19. Shoulder Magnetic Resonance Arthrography: A Prospective Randomized Study of Anterior and Posterior Ultrasonography-Guided Contrast Injections

    Energy Technology Data Exchange (ETDEWEB)

    Koivikko, M.P.; Mustonen, A.O.T. (Dept. of Radiology, Helsinki Univ. Central Hospital, Helsinki (Finland))

    2008-10-15

    , depending on anticipated shoulder pathology, is recommended. Because in posterior injections all artifacts were posterior and readily recognizable, it seems especially suitable for suspected anterior rotator cuff, joint capsule, and labral pathologies

  20. Shoulder Magnetic Resonance Arthrography: A Prospective Randomized Study of Anterior and Posterior Ultrasonography-Guided Contrast Injections

    International Nuclear Information System (INIS)

    , depending on anticipated shoulder pathology, is recommended. Because in posterior injections all artifacts were posterior and readily recognizable, it seems especially suitable for suspected anterior rotator cuff, joint capsule, and labral pathologies

  1. Guideline for Capsule Endoscopy: Obscure Gastrointestinal Bleeding

    OpenAIRE

    Shim, Ki-Nam; Moon, Jeong Seop; Chang, Dong Kyung; Do, Jae Hyuk; Kim, Ji Hyun; Min, Byung Hoon; Jeon, Seong Ran; Kim, Jin-Oh; Choi, Myung-Gyu; ,

    2013-01-01

    Capsule endoscopy (CE) is considered as a noninvasive and reliable diagnostic tool of examining the entire small bowel. CE has been performed frequently at many medical centers in South Korea; however, there is no evidence-based CE guideline for adequate diagnostic approaches. To provide accurate information and suggest correct testing approaches for small bowel disease, the guideline on CE was developed by the Korean Gut Image Study Group, a part of the Korean Society of Gastrointestinal End...

  2. Resorcinarenes are hexameric capsules in solution

    OpenAIRE

    Evan-Salem, Tamar; Baruch, Inbal; Avram, Liat; Cohen, Yoram; Palmer, Liam C.; Rebek, Julius

    2006-01-01

    The host–guest complexes of resorcin[4]arenes with small molecules in organic solutions are examined using modern NMR spectroscopic methods. The complexation of glutaric acid and β-methyl d-glucopyranoside in chloroform were investigated through 2D COSY, 2D NOESY, 1D NOE, and diffusion-ordered NMR spectroscopy (DOSY) techniques. These methods indicate that the complex is a self-assembled capsule composed of six resorcinarenes that surround six guest molecules of glutaric acid or three molecul...

  3. Study on Titanium Nitride Film Modified for Intraocular Lens

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective:To study the characteristics of the intraocular lens using ion beam sputtering depositing titanium nitride thin film on the intraocular lens(IOLs).Methods:To deposite titanium nitride thin film on the top of intraocular lens by ion beam sputtering depositing.We analyzed the surface morphology of intraocular lens through SEM and AFM.We detected intraocular lens resolution through the measurement of intraocular lens.Biocompatibility of intraocular lens is preliminary evaluated in this test.Results:T...

  4. Collapse of experimental capsules under external pressure

    Energy Technology Data Exchange (ETDEWEB)

    Simonen, F.A.; Shippell, R.J. Jr.

    1980-01-01

    Stress analyses and developmental tests of capsules fabricated from thick-walled tubing were performed for an external pressure design condition. In the design procedure no credit was taken for the expected margin in pressure between yielding of the capsule wall and catastrophic collapse or flattening. In tests of AISI-1018 low carbon steel capsules, a significant margin was seen between yield and collapse pressure. However, the experimental yield pressures were significantly below predictions, essentially eliminating the safety margin present in the conservative design approach. The differences between predictions and test results are attributed to deficiencies in the plasticity theories commonly in use for engineering stress analyses. The results of this study show that the von Mises yield condition does not accurately describe the yield behavior of the AISI-1018 steel tubing material for the triaxial stress conditions of interest. Finite element stress analyses successfully predicted the transition between uniform inward plastic deformation and ovalization that leads to catastrophic collapse. After adjustments to correct for the unexpected yield behavior of the tube material, the predicted pressure-deflection trends were found to follow the experimental data.

  5. Collapse of experimental capsules under external pressure

    International Nuclear Information System (INIS)

    Stress analyses and developmental tests of capsules fabricated from thick-walled tubing were performed for an external pressure design condition. In the design procedure no credit was taken for the expected margin in pressure between yielding of the capsule wall and catastrophic collapse or flattening. In tests of AISI-1018 low carbon steel capsules, a significant margin was seen between yield and collapse pressure. However, the experimental yield pressures were significantly below predictions, essentially eliminating the safety margin present in the conservative design approach. The differences between predictions and test results are attributed to deficiencies in the plasticity theories commonly in use for engineering stress analyses. The results of this study show that the von Mises yield condition does not accurately describe the yield behavior of the AISI-1018 steel tubing material for the triaxial stress conditions of interest. Finite element stress analyses successfully predicted the transition between uniform inward plastic deformation and ovalization that leads to catastrophic collapse. After adjustments to correct for the unexpected yield behavior of the tube material, the predicted pressure-deflection trends were found to follow the experimental data

  6. Lens Coupled Quantum Cascade Laser

    Science.gov (United States)

    Hu, Qing (Inventor); Lee, Alan Wei Min (Inventor)

    2013-01-01

    Terahertz quantum cascade (QC) devices are disclosed that can operate, e.g., in a range of about 1 THz to about 10 THz. In some embodiments, QC lasers are disclosed in which an optical element (e.g., a lens) is coupled to an output facet of the laser's active region to enhance coupling of the lasing radiation from the active region to an external environment. In other embodiments, terahertz amplifier and tunable terahertz QC lasers are disclosed.

  7. Lens transglutaminase and cataract formation.

    OpenAIRE

    Lorand, L.; Hsu, L K; Siefring, G E; Rafferty, N S

    1981-01-01

    A protein polymer characteristically present in human cataract was shown to contain significant amounts of gamma-glutamyl-epsilon-lysine isopeptides. It is proposed that these crosslinks are produced by the action of transglutaminase (R-glutaminyl-peptide:amine-gamma-glutamyl-yltransferase, EC 2.3.2.13), which is all the more plausible because lens contains the enzyme and endogenous protein substrates for it. The enzyme is similar to that obtained from liver and is Ca2+ dependent. Highest app...

  8. Acute and chronic tears of anterior cruciate ligament : role of gadolinium-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Jung; Jee, Won Hee; Im, Soo A; Chun, Ho Jong; Jung, Hyun Seouk; Kim, Soo Young; Kwon, Tae An; Song, Sun Wha; Choi, Kyu Ho [Catholic Univ. Medical College. Kangnam St. Mary' s Hospital, Seoul (Korea, Republic of)

    1998-07-01

    To evaluate the efficacy of fat-suppressed gadolinium-enhanced MR imaging in differentiating acute from chronic ligament tears of anterior cruciate ligament. Materials and Methods : MR images of 22 patients with arthroscopically proven complete tear of the anterior cruciate ligament were retrospectively reviewed. The interval between injury and MR examination was one day to seven years. When ligament tear was detected on MR image with three months of injury, the case was considered acute;if detected after three months had elapsed, it was judged to be chronic. The extent of contrast enhancement was graded as 1, 2 or 3; grade 1, enhancement was confined to the expected ligament region; grade 2, enhancement extended to the joint capsule; grade 3, enhancement extended beyond the joint capsule. The grades of contrast enhancement correlated with the acute and chronic stages of ligament tears. Associated bone bruise and/or adjacent soft tissue edema were also evaluated. Results : Among 15 patients with acute ligament tear, nine (60%) showed grade 3 enhancement; among seven in whom tearing was chronic, four (57%) showed grade 1 enhancement. Bone bruising was present in 100% of acute tears (15/15) and 29 % of chronic tears (2/7). Soft tissue edema was associated in 87% of acute tears (13/15) and 29% of chronic tears(2/7). Conclusion : Fat-suppressed gadolinium-enhanced MR imaging could help differentiate acute from chronic tears of anterior cruciate ligament, as well as bone bruising and tissue edema.

  9. Acute and chronic tears of anterior cruciate ligament : role of gadolinium-enhanced MR imaging

    International Nuclear Information System (INIS)

    To evaluate the efficacy of fat-suppressed gadolinium-enhanced MR imaging in differentiating acute from chronic ligament tears of anterior cruciate ligament. Materials and Methods : MR images of 22 patients with arthroscopically proven complete tear of the anterior cruciate ligament were retrospectively reviewed. The interval between injury and MR examination was one day to seven years. When ligament tear was detected on MR image with three months of injury, the case was considered acute;if detected after three months had elapsed, it was judged to be chronic. The extent of contrast enhancement was graded as 1, 2 or 3; grade 1, enhancement was confined to the expected ligament region; grade 2, enhancement extended to the joint capsule; grade 3, enhancement extended beyond the joint capsule. The grades of contrast enhancement correlated with the acute and chronic stages of ligament tears. Associated bone bruise and/or adjacent soft tissue edema were also evaluated. Results : Among 15 patients with acute ligament tear, nine (60%) showed grade 3 enhancement; among seven in whom tearing was chronic, four (57%) showed grade 1 enhancement. Bone bruising was present in 100% of acute tears (15/15) and 29 % of chronic tears (2/7). Soft tissue edema was associated in 87% of acute tears (13/15) and 29% of chronic tears(2/7). Conclusion : Fat-suppressed gadolinium-enhanced MR imaging could help differentiate acute from chronic tears of anterior cruciate ligament, as well as bone bruising and tissue edema

  10. A and B mode ultrasonography in preoperative evaluation of lens and posterior segment of dogs eyes with cataract

    Directory of Open Access Journals (Sweden)

    Bianca C. Martins

    2010-02-01

    Full Text Available Ultrasonography of the lens and posterior segment is an indispensable step in the preoperative evaluation of dogs with cataracts, since ophthalmoscopy is not feasible when there is opacification of the lens. This study evaluated the echographic conditions of cataractous lens and fundus of the eye in dogs affected by cataracts. The study was conducted in 30 dogs (56 eyes, 10 males and 20 females, with different types of cataracts at different stages of development. Echography in A and B modes, simultaneously, was carried out for the examination of the lens and posterior segment. The examinations revealed anterior cortical, posterior cortical and nuclear cataract in 12 eyes (21.4%, anterior cortical, posterior cortical, nuclear and posterior capsular in 23 eyes (41%, anterior cortical, posterior cortical and posterior capsular cataract in one eye (1.7%, anterior cortical and nuclear cataract in one eye (1.7%, anterior cortical, nuclear and posterior capsular cataract in five eyes (8.9%, and anterior cortical cataract in seven eyes (12.5%. Abnormal ultrasonographic alterations were observed in the posterior segment in 26 eyes evaluated (46.4%. Vitreal degeneration was detected in 12 eyes (21.4%, images of vitreal exudate or hemorrhage in seven eyes (12.5%, persistence of hyaloid artery in four eyes (7.1% and lens subluxation in three eyes (5.3%. The results obtained reiterate the importance of ultrasonography in canine patients presented for cataract surgery given that alterations of the posterior segment are difficult to identify in a clinical examination when the lens is opacified.A ultrassonografia do segmento posterior do bulbo do olho é etapa indispensável na avaliação de cães com catarata que serão submetidos à facectomia, uma vez que a oftalmoscopia não é factível quando há opacificação da lente, notadamente nas cataratas maduras. Este estudo avaliou as condições ecográficas da lente cataratogênica e do fundo de olho de c

  11. Refractive Outcomes of Three-Port Lens-Sparing Vitrectomy for Retinopathy of Prematurity (An AOS Thesis)

    Science.gov (United States)

    Holz, Eric R.

    2009-01-01

    Purpose: To study the refractive outcomes of 3-port lens-sparing vitrectomy (LSV) for subtotal retinal detachments due to retinopathy of prematurity (ROP). Lens-sparing vitrectomy may provide superior refractive outcomes by limiting induced myopia of prematurity. Methods: This is a retrospective, consecutive, nonrandomized, comparative (paired eye) study. Entrance criteria were previous complete ablative laser for threshold ROP in both eyes, followed by LSV in one eye for stage 4A traction retinal detachment. Both eyes then maintained complete retinal attachment. Main outcome variables were cycloplegic refraction, keratometry, and biometric values for axial length, lens thickness, and anterior chamber depth. Results: Nine patients met inclusion criteria. Lens-sparing vitrectomy eyes were significantly less myopic than control eyes (−6.78 D vs −10.33 D, P < .005). The reduction in myopia in LSV eyes was predominantly due to increased anterior chamber depth (3.81 mm ± 0.217 vs 2.96 mm ± 0.232, P < .005). There was a minor contribution from reduced corneal power in LSV eyes (43.89 D ± 0.253 vs 44.20 D ± 0.265, P < .005). There was a minor negative impact from increased lens thickness in LSV eyes (3.85 ± 0.32 mm vs 3.74 ± 0.31, P < .005). There was no significant difference in axial length or lens power between the LSV and control groups. Conclusions: The data demonstrate that infant eyes undergoing 3-port LSV for stage 4A ROP develop less myopia than fellow eyes treated with laser alone. The difference is due to posterior displacement of the lens-iris diaphragm with a smaller contribution from reduced corneal power. The reduction in myopia may improve functional outcomes following 3-port LSV for stage 4A ROP. PMID:20126504

  12. Motion of an elastic capsule in a square microfluidic channel.

    Science.gov (United States)

    Kuriakose, S; Dimitrakopoulos, P

    2011-07-01

    In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e., small, moderate, and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross section in the upstream portion of large capsules is nonaxisymmetric (i.e., square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a(-2) for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux-U ~ h ~ a(-2

  13. Capsule formation and asymbiotic seed germination in some hybrids of Phalaenopsis, influenced by pollination season and capsule maturity.

    Science.gov (United States)

    Balilashaki, Khosro; Gantait, Saikat; Naderi, Roohangiz; Vahedi, Maryam

    2015-07-01

    We explored the influence of pollination season and maturity of capsule on post-pollination capsule formation and in vitro asymbiotic seed germination, respectively. Three Phalaenopsis orchid hybrids, namely, 'Athens', 'Moscow' and 'Lusaka' flowers were artificially self-pollinated during winter, spring, summer and fall seasons and the impact of the pollination seasons was evident during capsule formation. It was observed that winter was the most suitable season for pollination of all the three Phalanaeopsis hybrids resulting in 80-88 % capsule formation. During summer, the pollination success rate was 24-28 %, but resulted in successful capsule formation. Season of pollination further delimited the germination efficiency of seeds harvested from capsules of variable maturity levels. Invariably, seeds collected from winter-pollinated capsules performed best in germination compared to other seasons, for instance, 'Moscow' seeds took less than 14 days to germinate from capsules developed following winter-pollination. Regarding the influence of capsule maturity on seed germination, we observed that seeds derived from 5-month mature capsules, invariably took least time to germinate than that of the 3-month or 7-month in all three hybrids, e.g., for 'Moscow' it was 13.9 days with a maximum of 90.3 % germination.

  14. A Review of Locomotion Systems for Capsule Endoscopy.

    Science.gov (United States)

    Liu, Lejie; Towfighian, Shahrzad; Hila, Amine

    2015-01-01

    Wireless capsule endoscopy for gastrointestinal (GI) tract is a modern technology that has the potential to replace conventional endoscopy techniques. Capsule endoscopy is a pill-shaped device embedded with a camera, a coin battery, and a data transfer. Without a locomotion system, this capsule endoscopy can only passively travel inside the GI tract via natural peristalsis, thus causing several disadvantages such as inability to control and stop, and risk of capsule retention. Therefore, a locomotion system needs to be added to optimize the current capsule endoscopy. This review summarizes the state-of-the-art locomotion methods along with the desired locomotion features such as size, speed, power, and temperature and compares the properties of different methods. In addition, properties and motility mechanisms of the GI tract are described. The main purpose of this review is to understand the features of GI tract and diverse locomotion methods in order to create a future capsule endoscopy compatible with GI tract properties. PMID:26292162

  15. Role of shocks and mix caused by capsule defects

    Science.gov (United States)

    Bradley, P. A.; Cobble, J. A.; Tregillis, I. L.; Schmitt, M. J.; Obrey, K. D.; Glebov, V.; Batha, S. H.; Magelssen, G. R.; Fincke, J. R.; Hsu, S. C.; Krasheninnikova, N. S.; Murphy, T. J.; Wysocki, F. J.

    2012-09-01

    An Eulerian code with a turbulent mix model is used to model a set of plastic (CH) ablator capsules with and without equatorial grooves. The "perfect" capsule results were used to calibrate simulations of capsules with equatorial grooves of different depths that provided information on increasingly perturbed implosions. Simulations with a turbulence model were able to calculate the same yield over mix (YOM) ratio (experiment/mix simulation) of 0.2 to 0.3 for thin (8-μm thick) and thick shell (15-μm thick) capsules with no grooves and thin capsules with shallow grooves. When the capsules have deep grooves, the YOM ratio increases to greater than unity, probably because the deformed shocks focus too strongly on the symmetry axis in our two-dimensional simulations. This is supported by a comparison of simulated and experimental x-ray images.

  16. Expanding role of capsule endoscopy in inflammatory bowel disease

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Capsule endoscopy has been shown to detect small bowel inflammatory changes better than any other imaging modality. Selection criteria have been optimized to increase the yield of capsule endoscopy in patients suspected to have Crohn's disease. Capsule endoscopy allows for earlier diagnosis of Crohn's disease of the small bowel and improved diagnosis of colitis in patients where it is unclear if they suffer from Crohn's or ulcerative colitis. A test capsule is available to assess for small bowel strictures and thus avoid capsule retention. A common language has been developed and a new scoring index will be added to capsule software. It is envisioned that the manner in which we treat Crohn's disease in the future will change, based on earlier diagnosis and treatment aimed at mucosal healing rather than symptom improvement.

  17. The motion of a deforming capsule through a corner

    CERN Document Server

    Zhu, Lailai

    2014-01-01

    A three-dimensional deformable capsule convected through a channel/duct with a corner is studied via numerical simulations using an accelerated boundary integral method adapted to general geometries. A global spectral method is adopted to resolve the dynamics of the capsule's membrane developing elastic tensions according to the Neo-Hookean constitutive law and bending moments in an inertialess flow. The simulations show that the trajectory of the capsule closely follows the underlying streamlines and the deformation of the capsule induces an anti-clockwise rotation of its material points with respect to the travelling direction. The surface area, principle tension and elastic energy of the capsule increase around the corner. Their temporal evolutions are characterised by a clear phase delay and the loss of time-reversal symmetry of Stokes flow due to the elasticity of membrane. The capsule centroid velocity decreases approaching the corner as the mean flow does while a velocity overshoot is observed past the...

  18. Role of shocks and mix caused by capsule defects

    International Nuclear Information System (INIS)

    An Eulerian code with a turbulent mix model is used to model a set of plastic (CH) ablator capsules with and without equatorial grooves. The “perfect” capsule results were used to calibrate simulations of capsules with equatorial grooves of different depths that provided information on increasingly perturbed implosions. Simulations with a turbulence model were able to calculate the same yield over mix (YOM) ratio (experiment/mix simulation) of 0.2 to 0.3 for thin (8-μm thick) and thick shell (15-μm thick) capsules with no grooves and thin capsules with shallow grooves. When the capsules have deep grooves, the YOM ratio increases to greater than unity, probably because the deformed shocks focus too strongly on the symmetry axis in our two-dimensional simulations. This is supported by a comparison of simulated and experimental x-ray images.

  19. Capsule development and utilization for material irradiation tests

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N. [and others

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules.

  20. Lateral shear interferometry with holo shear lens

    Science.gov (United States)

    Joenathan, C.; Mohanty, R. K.; Sirohi, R. S.

    1984-12-01

    A simple method for obtaining lateral shear using holo shear lenses (HSL) has been discussed. This simple device which produces lateral shears in the orthogonal directions has been used for lens testing. The holo shear lens is placed at or near the focus of the lens to be tested. It has also been shown that HSL can be used in speckle shear interferometry as it performs both the functions of shearing and imaging.

  1. An inverse and analytic lens design method

    OpenAIRE

    Lu, Yang; Lakshminarayanan, Vasudevan

    2016-01-01

    Traditional lens design is a numerical and forward process based on ray tracing and aberration theory. This method has limitations because the initial configuration of the lens has to be specified and the aberrations of the lenses have to considered. This paper is an initial attempt to investigate an analytic and inverse lens design method, called Lagrange, to overcome these barriers. Lagrange method tries to build differential equations in terms of the system parameters and the system input ...

  2. Fibrous Calcareous Concretions in the Capsules of Human Pineal Glands

    OpenAIRE

    Kodaka Tetsuo; Mori Ryoichi; Ezure Hiromitsu; Ito Junji; Otsuka Naruhito

    2013-01-01

    We examined calcareous concretions in the capsule of 15 human pineal glands containing a large amount of the concretions in the matrix. The capsule concretions, brown to blackish-brown in color and/or translucent, were smaller than the matrix concretions, which were yellowish-white. The matrix concretions showed the typical mulberry-shaped overall appearance with scallop-shaped concentric laminations of non-fibrous structures, but the capsule concretions, which also contained Ca and P, showed...

  3. The lens and source of the optical Einstein ring gravitational lens ER 0047-2808

    OpenAIRE

    Wayth, Randall B.; Warren, Stephen J.; Lewis, Geraint F.; Hewett, Paul C.

    2004-01-01

    (Abridged) We perform a detailed analysis of the optical gravitational lens ER 0047-2808 imaged with WFPC2 on the Hubble Space Telescope. Using software specifically designed for the analysis of resolved gravitational lens systems, we focus on how the image alone can constrain the mass distribution in the lens galaxy. We find the data are of sufficient quality to strongly constrain the lens model with no a priori assumptions about the source. Using a variety of mass models, we find statistica...

  4. Algorithm design of liquid lens inspection system

    Science.gov (United States)

    Hsieh, Lu-Lin; Wang, Chun-Chieh

    2008-08-01

    In mobile lens domain, the glass lens is often to be applied in high-resolution requirement situation; but the glass zoom lens needs to be collocated with movable machinery and voice-coil motor, which usually arises some space limits in minimum design. In high level molding component technology development, the appearance of liquid lens has become the focus of mobile phone and digital camera companies. The liquid lens sets with solid optical lens and driving circuit has replaced the original components. As a result, the volume requirement is decreased to merely 50% of the original design. Besides, with the high focus adjusting speed, low energy requirement, high durability, and low-cost manufacturing process, the liquid lens shows advantages in the competitive market. In the past, authors only need to inspect the scrape defect made by external force for the glass lens. As to the liquid lens, authors need to inspect the state of four different structural layers due to the different design and structure. In this paper, authors apply machine vision and digital image processing technology to administer inspections in the particular layer according to the needs of users. According to our experiment results, the algorithm proposed can automatically delete non-focus background, extract the region of interest, find out and analyze the defects efficiently in the particular layer. In the future, authors will combine the algorithm of the system with automatic-focus technology to implement the inside inspection based on the product inspective demands.

  5. Double-mirror peripheral vitrectomy lens.

    Science.gov (United States)

    Ohji, M; Tano, Y

    1995-11-01

    Many surgeons use prism lenses to see the periphery of the fundus during vitrectomy; however, chromatic aberrations in higher-power prismatic lenses cause blurring of the peripheral image. For better visualization of the periphery of the fundus, we developed a new contact lens, the double-mirror peripheral vitrectomy lens. The new lens is a quartz cylinder with two mirrors, and it provides a crisp, clear, upright image of much more of the peripheral fundus than is visible through conventional prism lenses. The new lens also provides a wider area of view than conventional prism lenses. PMID:7487611

  6. Increasing Z-pinch vacuum hohlraum capsule coupling efficiency.

    Energy Technology Data Exchange (ETDEWEB)

    Callahan, Debbie (LLNL); Vesey, Roger Alan; Cochrane, Kyle Robert (KTech); Nikroo, A. (General Atomics); Bennett, Guy R.; Schroen, Diana Grace (Schafer); Ruggles, Laurence E.; Porter, John L.; Streit, Jon (Schafer); Mehlhorn, Thomas Alan; Cuneo, Michael Edward

    2004-11-01

    Symmetric capsule implosions in the double-ended vacuum hohlraum (DEH) on Z have demonstrated convergence ratios of 14-21 for 2.15-mm plastic ablator capsules absorbing 5-7 kJ of x-rays, based on backlit images of the compressed ablator remaining at peak convergence [1]. Experiments with DD-filled 3.3-mm diameter capsules designed to absorb 14 kJ of x-rays have begun as an integrated test of drive temperature and symmetry, complementary to thin-shell symmetry diagnostic capsules. These capsule implosions are characterized by excellent control of symmetry (< 3% time-integrated), but low hohlraum efficiency (< 2%). Possible methods to increase the capsule absorbed energy in the DEH include mixed-component hohlraums, large diameter foam ablator capsules, transmissive shine shields between the z-pinch and capsule, higher spoke electrode x-ray transmission, a double-sided power feed, and smaller initial radius z-pinch wire arrays. Simulations will explore the potential for each of these modifications to increase the capsule coupling efficiency for near-term experiments on Z and ZR.

  7. Preparation of alginate-gelatin capsules and its properties

    Institute of Scientific and Technical Information of China (English)

    Xiao-yan LI; Xi-guang CHEN; Cheng-sheng LIU; Chen-guang LIU; Yu-ping XUE

    2008-01-01

    Capsules based on alginate and gelatin prepared by extrusion method could increase the cell numbers of Lactobacillus casei ATCC 393 to be 108 CFU·9-1 in the wet state of the capsules. The capsules were spherical, smooth-surfaced and non-aggregated with a diameter of (4.0±0.3) mm. The behavior of the samples were quite similar at low relative humidity (33%, 52%) and the ratio of weight change reached 93%. Four kinds of capsules in simulated gastric fluid (SGF) exhibited shrinkage while the beads eroded accompanied with slight swelling in simulated intestinal fluid (SIF). The pH values affected the stability of the capsules and with the increase in pH, the capsules chan-ged from shrank then swelled and finally, broke into pieces. The capsules behaved differently under different ion intens-ities and the introduction of gelatin weakened the stability of capsules compared with the alginate ones. Cells of L. casei ATCC 393 could be continuously released from the capsules in the simulated gastrointestinal tract (GIT) and the release amounts and speeds in SIF were much higher and faster than those in SGF.

  8. Small intestinal model for electrically propelled capsule endoscopy

    Directory of Open Access Journals (Sweden)

    Woo Sang Hyo

    2011-12-01

    Full Text Available Abstract The aim of this research is to propose a small intestine model for electrically propelled capsule endoscopy. The electrical stimulus can cause contraction of the small intestine and propel the capsule along the lumen. The proposed model considered the drag and friction from the small intestine using a thin walled model and Stokes' drag equation. Further, contraction force from the small intestine was modeled by using regression analysis. From the proposed model, the acceleration and velocity of various exterior shapes of capsule were calculated, and two exterior shapes of capsules were proposed based on the internal volume of the capsules. The proposed capsules were fabricated and animal experiments were conducted. One of the proposed capsules showed an average (SD velocity in forward direction of 2.91 ± 0.99 mm/s and 2.23 ± 0.78 mm/s in the backward direction, which was 5.2 times faster than that obtained in previous research. The proposed model can predict locomotion of the capsule based on various exterior shapes of the capsule.

  9. Increasing Z-pinch vacuum hohlraum capsule coupling efficiency

    International Nuclear Information System (INIS)

    Symmetric capsule implosions in the double-ended vacuum hohlraum (DEH) on Z have demonstrated convergence ratios of 14-21 for 2.15-mm plastic ablator capsules absorbing 5-7 kJ of x-rays, based on backlit images of the compressed ablator remaining at peak convergence (1). Experiments with DD-filled 3.3-mm diameter capsules designed to absorb 14 kJ of x-rays have begun as an integrated test of drive temperature and symmetry, complementary to thin-shell symmetry diagnostic capsules. These capsule implosions are characterized by excellent control of symmetry (< 3% time-integrated), but low hohlraum efficiency (< 2%). Possible methods to increase the capsule absorbed energy in the DEH include mixed-component hohlraums, large diameter foam ablator capsules, transmissive shine shields between the z-pinch and capsule, higher spoke electrode x-ray transmission, a double-sided power feed, and smaller initial radius z-pinch wire arrays. Simulations will explore the potential for each of these modifications to increase the capsule coupling efficiency for near-term experiments on Z and ZR

  10. Design procedure of capsule with multistage heater control (named MUSTAC)

    International Nuclear Information System (INIS)

    A capsule with electric heaters at multistage (named MUSTAC) is a type of capsule used in JMTR. The heaters are assembled in the capsule. Supply electric current to the heaters can be independently adjusted with a control systems that keeps irradiation specimens to constant temperature. The capsule being used, the irradiation specimen are inserted into specimen holders. Gas-gap size, between outer surface of specimen holders and inner surface of capsule casing, is calculated and determined to be flatten temperature of loaded specimens over the region. The rise or drop of specimen temperature in accordance with reactor power fluctuations is corrected within the target temperature of specimen by using the heaters filled into groove at specimen holder surface. The present report attempts to propose a reasonable design procedure of the capsules by means of compiling experience for designs, works and irradiation data of the capsules and to prepare for useful informations against onward capsule design. The key point of the capsule lies on thermal design. Now design thermal calculations are complicated in case of specimen holder with multihole. Resolving these issues, it is considered from new on that an emphasis have to placed on settling a thermal calculation device, for an example, a computer program on calculation specimen temperature. (author)

  11. Coculture with intraocular lens material-activated macrophages induces an inflammatory phenotype in lens epithelial cells.

    Science.gov (United States)

    Pintwala, Robert; Postnikoff, Cameron; Molladavoodi, Sara; Gorbet, Maud

    2015-03-01

    Cataracts are the leading cause of blindness worldwide, requiring surgical implantation of an intraocular lens. Despite evidence of leukocyte ingress into the postoperative lens, few studies have investigated the leukocyte response to intraocular lens materials. A novel coculture model was developed to examine macrophage activation by hydrophilic acrylic (poly(2-hydroxyethyl methacrylate)) and hydrophobic acrylic (polymethylmethacrylate) commercial intraocular lens. The human monocytic cell line THP-1 was differentiated into macrophages and cocultured with human lens epithelial cell line (HLE-B3) with or without an intraocular lens for one, two, four, or six days. Using flow cytometry and confocal microscopy, expression of the macrophage activation marker CD54 (intercellular adhesion molecule-1) and production of reactive oxygen species via the fluorogenic probe 2',7'-dichlorodihydrofluorescein diacetate were examined in macrophages. α-Smooth muscle actin, a transdifferentiation marker, was characterized in lens epithelial cells. The poly(2-hydroxyethyl methacrylate) intraocular lens prevented adhesion but induced significant macrophage activation (p intraocular lens), while the polymethylmethacrylate intraocular lens enabled adhesion and multinucleated fusion, but induced no significant activation. Coculture with either intraocular lens increased reactive oxygen species production in macrophages after one day (p intraocular lens, with hydrophilic surfaces inducing higher activation than hydrophobic surfaces. These findings provide a new method of inquiry into uveal biocompatibility, specifically through the quantification of cell-surface markers of leukocyte activation.

  12. Clinical outcomes of pars plicata anterior vitrectomy: 2-year results

    Directory of Open Access Journals (Sweden)

    Priya Narang

    2015-01-01

    Full Text Available Purpose: To demonstrate the safety and outcome of a surgical approach that uses pars plicata site for anterior vitrectomy during phacoemulsification procedure complicated by posterior capsule rupture and residual cortical matter. Design: Single center, retrospective, interventional, noncomparative study. Materials and Methods: Medical records of a consecutive series of 35 eyes of 35 patients who underwent pars plicata anterior vitrectomy (PPAV were reviewed. The main outcome measures were corrected and uncorrected distance visual acuity (CDVA, UDVA, early and late postoperative complications and intraocular pressure (IOP. Ultrasound biomicroscopic (UBM evaluation of sclerotomy site and spectral domain optical coherence tomography analysis for central macular thickness (CMT was performed. The final visual outcome at 2 years was evaluated. Results: At 2 years follow-up, the mean postoperative UDVA (logarithm of the minimum angle of resolution [logMAR] and CDVA (logMAR was 0.49 ± 0.26 and 0.19 ± 0.14, respectively. There was no significant change in the IOP (P = 0.061 and the mean CMT at 2 years was 192.5 ± 5.54 mm. The postoperative UBM image of the sclerotomy site at 8 weeks demonstrated a clear wound without any vitreous adhesion or incarceration. Intraoperative hyphema was seen in 1 (2.8% case and postoperative uveitis was seen in 2 (5.7% cases, which resolved with medications. No case of an iatrogenic retinal break or retinal detachment was reported. Conclusions: PPAV enables a closed chamber approach, allows thorough cleanup of vitreous in the pupillary plane and anterior chamber and affords better access to the subincisional and retropupillary cortical remnant with a significant visual outcome and an acceptable complication rate.

  13. Ocular Coherence Tomography in the Evaluation of Anterior Eye Injuries in Space Flight

    Science.gov (United States)

    Fer, Dan M.; Law, Jennifer; Wells, Julia

    2017-01-01

    While Ocular Coherence Tomography (OCT) is not a first-line modality to evaluate anterior eye structures terrestrially, it is a resource already available on the International Space Station (ISS) that can be used in medical contingencies that involve the anterior eye. With remote guidance and subject matter expert (SME) support from the ground, a minimally trained crewmember can now use OCT to evaluate anterior eye pathologies on orbit. OCT utilizes low-coherence interferometry to produce detailed cross-sectional and 3D images of the eye in real time. Terrestrially, it has been used to evaluate macular pathologies and glaucoma. Since 2013, OCT has been used onboard the ISS as one part of a suite of hardware to evaluate the Visual Impairment/Intracranial Pressure risk faced by astronauts, specifically assessing changes in the retina and choroid during space flight. The Anterior Segment Module (ASM), an add-on lens, was also flown for research studies, providing an opportunity to evaluate the anterior eye in real time if clinically indicated. Anterior eye pathologies that could be evaluated using OCT were identified. These included corneal abrasions and ulcers, scleritis, and acute angle closure glaucoma. A remote guider script was written to provide ground specialists with step-by-step instructions to guide ISS crewmembers, who do not get trained on the ASM, to evaluate the anterior eye. The instructions were tested on novice subjects and/or operators, whose feedback was incorporated iteratively. The final remote guider script was reviewed by SME optometrists and NASA flight surgeons. The novel application of OCT technology to space flight allows for the acquisition of objective data to diagnose anterior eye pathologies when other modalities are not available. This demonstrates the versatility of OCT and highlights the advantages of using existing hardware and remote guidance skills to expand clinical capabilities in space flight.

  14. Paediatric intraocular lens implants: accuracy of lens power calculations.

    Science.gov (United States)

    O'Gallagher, M K; Lagan, M A; Mulholland, C P; Parker, M; McGinnity, G; McLoone, E M

    2016-09-01

    PurposeThis study aims to evaluate the accuracy of lens prediction formulae on a paediatric population.MethodsA retrospective case-note review was undertaken of patients under 8 years old who underwent cataract surgery with primary lens implantation in a regional referral centre for paediatric ophthalmology, excluding those whose procedure was secondary to trauma. Biometric and refractive data were analysed for 43 eyes, including prediction errors (PE). Statistical measures used included mean absolute error (MAE), median absolute error (MedAE), Student's t-test and Lin's correlation coefficient.ResultsThe mean PE using the SRK-II formula was +0.96 D (range -2.47D to +2.41 D, SD 1.33 D, MAE 1.38 D, MedAE 1.55, n=15). The mean PE was smaller using SRK/T (-0.18 D, range -3.25 D to +3.95 D, SD 1.70 D, MAE 1.30 D, MedAE 1.24, n=27). We performed an analysis of the biometry data using four different formula (Hoffer Q, Holladay 1, SRK-II and SRK/T). Hoffer Q showed a smaller MedAE than other formulae but also a myopic bias.ConclusionOur clinical data suggest SRK/T was more accurate in predicting post-operative refraction in this cohort of paediatric patients undergoing cataract surgery. Hoffer Q may have improved accuracy further.

  15. Atom lens without chromatic aberrations

    CERN Document Server

    Efremov, Maxim A; Schleich, Wolfgang P

    2012-01-01

    We propose a lens for atoms with reduced chromatic aberrations and calculate its focal length and spot size. In our scheme a two-level atom interacts with a near-resonant standing light wave formed by two running waves of slightly different wave vectors, and a far-detuned running wave propagating perpendicular to the standing wave. We show that within the Raman-Nath approximation and for an adiabatically slow atom-light interaction, the phase acquired by the atom is independent of the incident atomic velocity.

  16. Flat lens for seismic waves

    CERN Document Server

    Brule, Stephane; Guenneau, Sebastien

    2016-01-01

    A prerequisite for achieving seismic invisibility is to demonstrate the ability of civil engineers to control seismic waves with artificially structured soils. We carry out large-scale field tests with a structured soil made of a grid consisting of cylindrical and vertical holes in the ground and a low frequency artificial source (< 10 Hz). This allows the identification of a distribution of energy inside the grid, which can be interpreted as the consequence of an effective negative refraction index. Such a flat lens reminiscent of what Veselago and Pendry envisioned for light opens avenues in seismic metamaterials to counteract the most devastating components of seismic signals.

  17. Intraocular lens with accommodation capacity

    OpenAIRE

    Dorronsoro, Carlos; Alejandre, Nicolás; Bekesi, Nandor; Marcos, Susana

    2014-01-01

    Intraocular lens with accommodation capacity comprising a first optical member (1) having a dynamic optical power, to which a second optical member (2) with a fixed optical power is affixed, in such a manner that at least a central part of each of one of one of the curved surfaces (2a, 2b) of the second optical member (2) and of at least one of the surfaces (1a, 1b) of the first optical member (1) are in contact with each other, the second optical member (2) and the first optical member (1) p...

  18. Postirradiation examination of capsule GF-4

    International Nuclear Information System (INIS)

    The GF-4 capsule test was irradiated in the SILOE reactor at Grenoble, France between April 8, 1975 and July 26, 1976. High-enriched uranium (HEU) UC2 and weak acid resin (WAR) UC/sub x/O/sub y/ fissile and ThO2 fertile particles were tested. Postirradiation examination of cured-in-place fuel rods showed no fuel rod/graphite element interaction. In addition, all rods exhibited adequate structural integrity. Irradiation-induced dimensional changes for rods containing all TRISO-coated fuel were consistent with model predictions; however, rods containing BISO-coated fuel exhibited greater volumetric contractions than predicted

  19. Anterior cruciate ligament - updating article.

    Science.gov (United States)

    Luzo, Marcus Vinicius Malheiros; Franciozi, Carlos Eduardo da Silveira; Rezende, Fernando Cury; Gracitelli, Guilherme Conforto; Debieux, Pedro; Cohen, Moisés

    2016-01-01

    This updating article on the anterior cruciate ligament (ACL) has the aim of addressing some of the most interesting current topics in this field. Within this stratified approach, it contains the following sections: ACL remnant; anterolateral ligament and combined intra and extra-articular reconstruction; fixation devices; and ACL femoral tunnel creation techniques.

  20. Anterior cruciate ligament - updating article.

    Science.gov (United States)

    Luzo, Marcus Vinicius Malheiros; Franciozi, Carlos Eduardo da Silveira; Rezende, Fernando Cury; Gracitelli, Guilherme Conforto; Debieux, Pedro; Cohen, Moisés

    2016-01-01

    This updating article on the anterior cruciate ligament (ACL) has the aim of addressing some of the most interesting current topics in this field. Within this stratified approach, it contains the following sections: ACL remnant; anterolateral ligament and combined intra and extra-articular reconstruction; fixation devices; and ACL femoral tunnel creation techniques. PMID:27517015

  1. Arthroscopic Latarjet and Capsular Shift (ALCS) procedure: a new "freehand" technique for anterior shoulder instability associated with significant bone defects.

    Science.gov (United States)

    Bhatia, Deepak N

    2015-03-01

    Anterior shoulder instability associated with significant bone loss has been described as "bony-instability," and this condition is usually treated with an anterior glenoid bone grafting procedure (Latarjet procedure). The Latarjet procedure involves transfer of the horizontal limb of the coracoid process along with the conjoint tendon to the anterior glenoid rim, and is traditionally performed as an open surgical procedure. Recently, an arthroscopic technique for the Latarjet procedure has been described; the technique necessitates the use of specialized instrumentation and involves excision of the entire anterior capsule to facilitate coracoid fixation. We describe a new "freehand" arthroscopic technique for the Latarjet procedure, and, in addition, a simultaneous capsular shift to further optimize mid and end range stability. This technique eliminates the use of additional instrumentation and can be done using routine arthroscopic instruments. Preliminary experience with this technique suggests that the arthroscopic Latarjet and capsular shift is a technically demanding procedure. Glenohumeral capsule can be preserved, and this should be attempted wherever possible to optimize stability. Additional specialized instrumentation would probably reduce surgical time; however, the procedure can be performed with routine instruments.

  2. Válvula de uretra anterior Anterior urethral valves

    Directory of Open Access Journals (Sweden)

    Silvio Tucci Jr.

    2003-02-01

    Full Text Available Objetivo: apresentar os aspectos clínicos, diagnósticos e terapêuticos de pacientes portadores de válvula da uretra anterior. Descrição: em dois neonatos, o diagnóstico presuntivo de patologia obstrutiva do trato urinário foi sugerido pela ultra-sonografia realizada no período pré-natal, confirmando-se o diagnóstico de válvula de uretra anterior pela avaliação pós-natal. Os pacientes foram submetidos a tratamento cirúrgico paliativo, com vesicostomia temporária e, posteriormente, definitivo, pela fulguração endoscópica das válvulas. Ambos evoluíram com função renal normal. Comentários: a válvula da uretra anterior é anomalia rara que deve ser considerada em meninos com quadro radiológico pré-natal sugestivo de obstrução infravesical, secundariamente à hipótese mais comum de válvula da uretra posterior. Ressaltamos a utilização da vesicostomia como derivação urinária temporária nestes casos, prevenindo potenciais complicações pela manipulação da uretra do recém-nascido.Objective: to discuss clinical signs, diagnostic tools and therapeutics of anterior urethral valves, an obstructive anomaly of the urinary system in males. Description: signs of urinary tract obstruction were identified on pre-natal ultrasound in two male fetuses and the diagnosis of anterior urethral valves was made through post-natal evaluation. As an initial treatment, vesicostomy was performed in both patients. Later, the valves were fulgurated using an endoscopic procedure. During the follow-up period both patients presented normal renal function. Comments: anterior urethral valves are a rare form of urethral anomaly that must be ruled out in boys with pre-natal ultrasound indicating infravesical obstruction. Vesicostomy used as an initial treatment rather than transurethral fulguration may prevent potential complications that can occur due to the small size of the neonatal urethra.

  3. New reduced volume preparation regimen in colon capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    Yasuo Kakugawa; Kazuhide Higuchi; Shinji Tanaka; Hideki Ishikawa; Hisao Tajiri; Yutaka Saito; Shoichi Saito; Kenji Watanabe; Naoki Ohmiya; Mitsuyuki Murano; Shiro Oka; Tetsuo Arakawa; Hidemi Goto

    2012-01-01

    AIM:To evaluate the effectiveness of our proposed bowel preparation method for colon capsule endoscopy.METHODS:A pilot,multicenter,randomized controlled trial compared our proposed "reduced volume method" (group A) with the "conventional volume method" (group B) preparation regimens.Group A did not drink polyethylene glycol electrolyte lavage solution (PEGELS) the day before the capsule procedure,while group B drank 2 L.During the procedure day,groups A and B drank 2 L and 1 L of PEG-ELS,respectively,and swallowed the colon capsule (PillCam COLON(R) capsule).Two hours later the first booster of 100 g magnesium citrate mixed with 900 mL water was administered to both groups,and the second booster was administered six hours post capsule ingestion as long as the capsule had not been excreted by that time.Capsule videos were reviewed for grading of cleansing level.RESULTS:Sixty-four subjects were enrolled,with results from 60 analyzed.Groups A and B included 31 and 29 subjects,respectively.Twenty-nine (94%) subjects in group A and 25 (86%) subjects in group B had adequate bowel preparation (ns).Twenty-two (71%) of the 31 subjects in group A excreted the capsule within its battery life compared to 16 (55%) of the 29 subjects in group B (ns).Of the remaining 22 subjects whose capsules were not excreted within the battery life,all of the capsules reached the left side colon before they stopped functioning.A single adverse event was reported in one subject who had mild symptoms of nausea and vomiting one hour after starting to drink PEG-ELS,due to ingesting the PEG-ELS faster than recommended.CONCLUSION:Our proposed reduced volume bowel preparation method for colon capsule without PEG-ELS during the days before the procedure was as effective as the conventional volume method.

  4. Anatomia microcirúgica da substâcia perfurada anterior basal humana Microsurgical anatomy of the human basal anterior perforated substance

    Directory of Open Access Journals (Sweden)

    Arlindo Alfredo Silveira D’Ávila

    2006-06-01

    Full Text Available A substância perfurada anterior constitui referencial na base do encéfalo. Localizada acima da bifurcação subaracnóidea da artéria carótida interna em sua porção basal e junto à artéria comunicante anterior na face inter-hemisférica, é transfixada por ramos perfurantes dirigidos aos núcleos telencefálicos corticais, cápsula interna e parte do tálamo. Por injeção intravascular de gelatina carminada, resina de Batson e látex, analisamos 50 hemisférios cerebrais humanos adultos de ambos os sexos, sob o microscópio cirúrgico. Objetivamos contribuir para a determinação da origem, número e topografia dos ramos destinados a essa região, seu curso, anastomoses e territórios de penetração. Propusemo-nos também a analisar a contribuição da artéria comunicante anterior à substância perfurada anterior. Foram encontradas variações anatômicas, incluindo anastomoses, envolvendo principalmente a artéria cerebral média e a artéria coróidea anterior. Estes conhecimentos são de interesse clínico-cirúrgico em razão da freqüência de patologias vasculares e tumorais a ela relacionadas.The anterior perforated substance (APS is a landmark in the basal forebrain. It has a basal face located above the carotid bifurcation in the subarachnoid space, and an interhemispheric one. It is the site of passage of the arteries to the caudate nucleus, putamen, internal capsule, adjacent areas of the globus pallidus and thalamus. Fifty hemispheres from twenty-five adult cadavers were obtained. The arteries were perfused with colored latex, Batson’s resin and gelatin colored with carmine. Using a surgical microscope we have determined the origin, local and number of origin from the parent vessel. The sites of penetration in the mediolateral and anteroposterior direction were also recorded. The anterior communicating artery contribution to the basal APS was reviewed. Significant vascular variations and anastomoses were encountered

  5. Protection of the eye lens

    International Nuclear Information System (INIS)

    The limit of radiation exposure for eye lens is going to decrease dramatically from 150 to 20 mSv as a transposition into the French law of a CIPR (International Commission for Radiation Protection) directive. Sanitary studies have shown that radiologists are more likely by a factor of 3.8 to get eye lens opacities than the rest of the population. The wearing of protective glasses is recommended and in order to get a better monitoring of the radiation dose new dosimeters have been designed, they can be worn on the glass frame of directly stuck on the skin near the eyes. A study has shown that veterinary surgeons that are accustomed to stay near animals to keep them quiet during radiological exams are prone to receive high doses as well as physicians that use hypnosis to decrease the level of anxiety of their patients during radiological exams. Radiation exposure of radiologists can be mitigated through: the use of protective shields and equipment and the optimization of the dose delivered to the patient. (A.C.)

  6. Contact lens sensors in ocular diagnostics.

    Science.gov (United States)

    Farandos, Nicholas M; Yetisen, Ali K; Monteiro, Michael J; Lowe, Christopher R; Yun, Seok Hyun

    2015-04-22

    Contact lenses as a minimally invasive platform for diagnostics and drug delivery have emerged in recent years. Contact lens sensors have been developed for analyzing the glucose composition of tears as a surrogate for blood glucose monitoring and for the diagnosis of glaucoma by measuring intraocular pressure. However, the eye offers a wider diagnostic potential as a sensing site and therefore contact lens sensors have the potential to improve the diagnosis and treatment of many diseases and conditions. With advances in polymer synthesis, electronics and micro/nanofabrication, contact lens sensors can be produced to quantify the concentrations of many biomolecules in ocular fluids. Non- or minimally invasive contact lens sensors can be used directly in a clinical or point-of-care setting to monitor a disease state continuously. This article reviews the state-of-the-art in contact lens sensor fabrication, their detection, wireless powering, and readout mechanisms, and integration with mobile devices and smartphones. High-volume manufacturing considerations of contact lenses are also covered and a case study of an intraocular pressure contact lens sensor is provided as an example of a successful product. This Review further analyzes the contact lens market and the FDA regulatory requirements for commercialization of contact lens sensors. PMID:25400274

  7. Potential value of Cs-137 capsules

    Energy Technology Data Exchange (ETDEWEB)

    Bloomster, C.H.; Brown, D.R.; Bruno, G.A.; Hazelton, R.F.; Hendrickson, P.L.; Lezberg, A.J.; Tingey, G.L.; Wilfert, G.L.

    1985-04-01

    We determined the value of Cs-137 compared to Co-60 as a source for the irradiation of fruit (apples and cherries), pork and medical supplies. Cs-137, in the WESF capsule form, had a value of approximately $0.40/Ci as a substitute for Co-60 priced at approximately $1.00/Ci. The comparison was based on the available curies emitted from the surface of each capsule. We developed preliminary designs for fourteen irradiation facilities; seven were based on Co-60 and seven were based on Cs-137. These designs provided the basis for estimating capital and operating costs which, in turn, provided the basis for determining the value of Cs-137 relative to Co-60 in these applications. We evaluated the effect of the size of the irradiation facility on the value of Cs-137. The cost of irradiation is low compared to the value of the product. Irradiation of apples for disinfestation costs $.01 to .02 per pound. Irradiation for trichina-safe pork costs $.02 per pound. Irradiation of medical supplies for sterilization costs $.07 to .12 per pound. The cost of the irradiation source, either Co-60 or Cs-137, contributed only a minor amount to the total cost of irradiation, about 5% for the fruit and hog cases and about 20% for the medical supply cases. We analyzed the sensitivity of the irradiation costs and Cs-137 value to several key assumptions.

  8. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Directory of Open Access Journals (Sweden)

    M Isabel Canut Jordana

    2010-11-01

    Full Text Available M Isabel Canut Jordana1, Daniel Pérez Formigó1, Rodrigo Abreu González2, Jeroni Nadal Reus11Barraquer Ophthalmology Centre, Barcelona, Spain; 2University Hospital of La Candelaria, Tenerife, SpainAims: We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact.Methods: Complete ophthalmologic examination and optical coherence tomography (OCT of the anterior segment were performed.Results: Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control.Conclusion: Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.Keywords: pigmentary glaucoma, intraocular lens, optical coherence tomography, laser

  9. Intraocular lens power estimation by accurate ray tracing for eyes underwent previous refractive surgeries

    Science.gov (United States)

    Yang, Que; Wang, Shanshan; Wang, Kai; Zhang, Chunyu; Zhang, Lu; Meng, Qingyu; Zhu, Qiudong

    2015-08-01

    For normal eyes without history of any ocular surgery, traditional equations for calculating intraocular lens (IOL) power, such as SRK-T, Holladay, Higis, SRK-II, et al., all were relativley accurate. However, for eyes underwent refractive surgeries, such as LASIK, or eyes diagnosed as keratoconus, these equations may cause significant postoperative refractive error, which may cause poor satisfaction after cataract surgery. Although some methods have been carried out to solve this problem, such as Hagis-L equation[1], or using preoperative data (data before LASIK) to estimate K value[2], no precise equations were available for these eyes. Here, we introduced a novel intraocular lens power estimation method by accurate ray tracing with optical design software ZEMAX. Instead of using traditional regression formula, we adopted the exact measured corneal elevation distribution, central corneal thickness, anterior chamber depth, axial length, and estimated effective lens plane as the input parameters. The calculation of intraocular lens power for a patient with keratoconus and another LASIK postoperative patient met very well with their visual capacity after cataract surgery.

  10. Zebrafish mutations in Gli-mediated hedgehog signaling lead to lens transdifferentiation from the adenohypophysis anlage.

    Science.gov (United States)

    Kondoh, H; Uchikawa, M; Yoda, H; Takeda, H; Furutani-Seiki, M; Karlstrom, R O

    2000-09-01

    It is known that the earliest lens marker delta-crystallin is expressed abundantly in Rathke's pouch of the chicken, suggesting a close relationship between the cell states of the adenohypophysis (pituitary) anlage and the early lens. We show here that the zebrafish midline mutants you-too (yot) and iguana (igu) develop lenses from the adenohypophysis anlage. The early adenohypophysis anlage of normal zebrafish expresses lim3 and six3 but in yot(ty119) mutants the anterior part of the anlage lacks lim3 expression, and instead produces a crystallin-expressing cell population which develops into a large lens structure expressing beta and gamma-crystallins, but is not associated with retina tissues. Among the zebrafish mutants with midline defects, midline lenses were observed in two mutant alleles of yot and an allele of igu, but not in other mutants (syu, con, smh, dtr, uml, spi and lok). Two yot mutant alleles with midline lenses likely encode dominant negative forms of the Gli2 protein which will interfere with transcriptional activation by other Gli proteins. The observation argues that overall inhibition of Shh-Gli signaling leads the adenohypophysis anlage to transdifferentiate into lens.

  11. Optimization of Zoom Lens with Discrete State of Liquid Lens Elements by Using Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Cheng-Mu Tsai

    2015-01-01

    Full Text Available This paper is to employ liquid lens elements to design a lens with zoom function by using the genetic algorithm (GA optimization. The liquid lens elements used in the proposal can apply voltage adjustment to generate the electrical field that induces the liquid with electric conductivity to vary the surface curvature between two different kinds of liquids. According to the voltage level, the liquid lens element makes the discrete variation of the curvature and thickness realize the zoom function without moving the lens groups so that the overall length can be reduced. However, it is difficult to design the zoom lens under the discrete variation of the curvature and thickness in the liquid lens elements and the mechanical space that is constantly limited. The GA offers a flexible way for lens optimization. We regarded the spot size as the fitness function to look for the optimum curvatures, thickness, and the corresponding statuses of liquid lens elements for the zoom lens. As a result, the zoom lens with constant space can be realized by running the selection, crossover, and mutation operation in the GA optimization.

  12. 25-G玻璃体手术系统在儿童白内障手术中的应用%Dry pars palna capsulotomy and anterior vitrectomy using 25-gauge vitrectomy system during, children cataract surgery

    Institute of Scientific and Technical Information of China (English)

    谢立信; 黄钰森

    2009-01-01

    Objective To describe the initial surgical experience and report the safety and feasibility of dry pars plana capsulotomy and anterior vitrectomy using a 25-gauge vitrectomy system in pediatric cataract surgery.Methods This Was a prospective case series study.After anterior continuous curvilinear capsulorhexis (ACCC) and phacoemulsification with intraocular lens (IOL) implantation in the capsule for all patients,a pars plana capsulotomy and anterior vitrectomy Was performed with a 25-gauge vitrectomy system using a dry technique in 40 eyes of 30 children with cataracts.Results All procedures were uneventful and all IOLs were implanted in the capsular bag.No intraoperative complications were noted attributable to the small-gauge instruments.The average follow-up period was eight months (range,4 to 30).Postoperative intraocular pressure remalned stable in most cases, except two eyes (5%) with transient hypotony during the first day after surgery.The postoperative inflammatory response Was mild.Ultrasound biomicroscopy showed complete healing of the sclerotomy at four weeks after surgery.No posterior synechia,posterior capsule opacification,IOL capture,vitreous prolapse,choroidal detachment or retinal detachment was observed throughout the follow-up period. Conclusions Dry pars plana capsulotomy and anterior vitrectomy using a 25-gauge vitrectomy system is safe and effective for the management of posterior lens capsules and anterior vitreous in pediatric cataract surgery.Prospective and comparative study is recommended to evaluate this procedure and traditional method.%目的 探讨儿童白内障手术中在无灌注状态下应用25-G玻璃体切除头切除视轴区晶状体后囊膜和玻璃体前皮质的安全性和有效性.方法 为前瞻性系列病例研究.对连续30例(40只眼)儿童白内障在全身麻醉下进行晶状体前囊环形撕开、白内障吸出和囊袋内折叠式人工晶状体(IOL)植入后,在前房保留黏弹剂

  13. Quality evaluation of simvastatin compounded capsules

    Directory of Open Access Journals (Sweden)

    Flávia Dias Marques-Marinho

    2011-09-01

    Full Text Available Simvastatin is commercially available as tablets and compounded capsules in Brazil. Very few reports regarding these capsules' quality, and consequently their efficacy, are available. The pharmaceutical quality of 30 batches of 20 mg simvastatin capsules from the market was evaluated by weight determination, content uniformity, disintegration (Brazilian Pharmacopeia, assay and dissolution test (USP32 tablet monograph. A HPLC method was developed for assay, content uniformity and dissolution test, and specifications were also established. Out of the 30 batches evaluated, 29 showed capsule disintegration within 45 min and individual weight variation was within ±10% or ±7.5% relative to average weight, for 300 mg, respectively. Only 27 batches met dissolution test criteria with values >80% of the labeled amount in 45 min; 21 batches showed simvastatin content between 90.0-110.0% of the labeled amount and 19 batches had at least 9 out of 10 capsules with content uniformity values between 85.0-115.0% of the labeled amount with RSDNo Brasil, a sinvastatina está comercialmente disponível na forma de comprimidos e cápsulas manipuladas. Poucos relatos estão disponíveis sobre a qualidade e, consequentemente, a eficácia dessas cápsulas. A qualidade de 30 lotes de sinvastatina 20 mg cápsulas do mercado foi avaliada através da determinação de peso, uniformidade de conteúdo, desintegração (Farmacopéia Brasileira, doseamento e teste de dissolução (monografia comprimidos USP32. Método por CLAE foi desenvolvido para o doseamento, uniformidade de conteúdo e teste de dissolução; além disso, especificações foram estabelecidas. Dos 30 lotes avaliados, 29 apresentaram desintegração da cápsula até 45 min e a variação do peso individual foi ± 10% ou ± 7,5% em relação ao peso médio, se 300 mg, respectivamente. Apenas 27 lotes preencheram os critérios do teste de dissolução com valores > 80% da quantidade rotulada, em 45 min, 21

  14. Protective Role of the Capsule and Impact of Serotype 4 Switching on Streptococcus mitis

    OpenAIRE

    Rukke, Håkon V.; Kalluru, Raja Sab; Repnik, Urska; Gerlini, Alice; José, Ricardo J.; Periselneris, Jimstan; Marshall, Helina; Griffiths, Gareth; Oggioni, Marco Rinaldo; Brown, Jeremy S.; Petersen, Fernanda C

    2014-01-01

    The polysaccharide capsule surrounding Streptococcus pneumoniae is essential for virulence. Recently, Streptococcus mitis, a human commensal and a close relative of S. pneumoniae, was also shown to have a capsule. In this study, the S. mitis type strain switched capsule by acquisition of the serotype 4 capsule locus of S. pneumoniae TIGR4, following induction of competence for natural transformation. Comparison of the wild type with the capsule-switching mutant and with a capsule deletion mut...

  15. Application of Fourier Domain OCT Imaging Technology to the Anterior Segment of the Human Eye

    Science.gov (United States)

    Wojtkowski, Maciej; Marcos, Susana; Ortiz, Sergio; Grulkowski, Ireneusz

    The anterior segment is the front part of the human eye, which forms the optical system and hence directly impacts vision. Traumatic or pathological changes in the anterior segment may lead to vision loss and, in some cases, even blindness. Since the eighteenth century, optical instrumentation for measuring and imaging the anterior segment of the human eye has been developing along with modern ophthalmology. The application of OCT to the anterior segment imaging is particularly of interest, since this could potentially provide substantial complementary information regarding the large-scale architecture of the cornea and the crystalline lens, or on small portions of tissue imaged with high spatial resolutions comparable to regular microscopy. Especially an introduction of Fourier domain detection in OCT has opened new frontiers in OCT ophthalmic applications. The resultant substantial speed improvement enables rapid image acquisition, helping to reduce artifacts due to patient motion. Thus, it is currently possible to perform high-speed, in vivo, three-dimensional volumetric imaging over large scales within a reasonable time limit and without reducing system sensitivity. This chapter describes the state-of the art OCT technology dedicated to anterior segment imaging and indicates all important parameters which are required for optimization of the performance of OCT instrument.

  16. All-dielectric subwavelength metasurface focusing lens.

    Science.gov (United States)

    West, Paul R; Stewart, James L; Kildishev, Alexander V; Shalaev, Vladimir M; Shkunov, Vladimir V; Strohkendl, Friedrich; Zakharenkov, Yuri A; Dodds, Robert K; Byren, Robert

    2014-10-20

    We have proposed, designed, manufactured and tested low loss dielectric micro-lenses for infrared (IR) radiation based on a dielectric metamaterial layer. This metamaterial layer was created by patterning a dielectric surface and etching to sub-micron depths. For a proof-of-concept lens demonstration, we have chosen a fine patterned array of nano-pillars with variable diameters. Gradient index (GRIN) properties were achieved by engineering the nano-pattern characteristics across the lens, so that the effective optical density of the dielectric metamaterial layer peaks around the lens center, and gradually drops at the lens periphery. A set of lens designs with reduced reflection and tailorable phase gradients have been developed and tested, demonstrating focal distances of a few hundred microns, beam area contraction ratio up to three, and insertion losses as low as 11%. PMID:25401653

  17. Capsule shields the function of short bacterial adhesins

    DEFF Research Database (Denmark)

    Schembri, Mark; Dalsgaard, D.; Klemm, Per

    2004-01-01

    Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can...

  18. Highly active antibody-modified magnetic polyelectrolyte capsules.

    Science.gov (United States)

    Valdepérez, Daniel; Del Pino, Pablo; Sánchez, Lourdes; Parak, Wolfgang J; Pelaz, Beatriz

    2016-07-15

    Polyelectrolyte hollow capsules are versatile platforms typically used for encapsulation of a wide variety of macromolecules in their cavity. The polymer shell of these capsules as composed by alternating layers of oppositely charged polyelectrolytes also allows for adding additional functionalities. The properties of the shell can be for example engineered by trapping different nanoparticles in-between the shell layers and/or by attaching bioactive molecules such as antibodies to the outermost layer. Herein, iron oxide NPs were inmobilized into the shell of polyelectrolyte capsules and the outermost layer of the shell was covalently modified with anti peroxidase antibodies. These capsules act as prototype model system, aiming to obtain a microstructure with the potential capability to specifically recognize and separate macromolecules. Due to the magnetic nanoparticles in the capsule shell, the capsules together with the attached target might be extracted by magnetic field gradients. Here we verified this approach by extracting horseradish peroxidase from a solution through magnetic separation with capsules bearing antibodies against horseradish peroxidase. The bioactivity of the capsules and the high degree of specific antibody functionalization were confirmed and quantified through an enzymatic reaction mediated by the extracted horseradish peroxidase. PMID:27089014

  19. Diamagnetically stabilized levitation control of an intraluminal magnetic capsule.

    Science.gov (United States)

    Lam, Michael; Mintchev, Martin

    2009-08-01

    Controlled navigation promotes full utilization of capsule endoscopy for reliable real-time diagnosis in the gastrointestinal (GI) tract, but intermittent natural peristalsis can disturb the navigational control, destabilize the capsule and take it out of levitation. The focus of the present work was to develop an economical and effective real-time magnetic capsule-guiding system that can operate in the presence of naturally existing peristalsis while retaining navigational control. A real-size magnetic navigation system that can handle peristaltic forces of up to 1.5 N was designed utilizing the computer-aided design (CAD) system Maxwell 3D (Ansoft, Pittsburg, PA) and was verified using a small-size physical experimental setup. The proposed system contains a pair of 50 cm diameter, 10,000-turn copper electromagnets with a 10 cm x 10 cm ferrous core driven by currents of up to 300 A and can successfully maintain position control over the levitating capsule during peristalsis. The addition of bismuth diamagnetic casing for stabilizing the levitating capsule was also studied. A modeled magnetic field around the diamagnetically cased permanent magnet was shown to be redistributed aligning its interaction with the external electromagnets, thus stabilizing the levitating capsule. In summary, a custom-designed diamagnetically facilitated capsule navigation system can successfully steer an intraluminal magnet-carrying capsule. PMID:19550023

  20. 1964 computer run on a laser-imploded capsule

    International Nuclear Information System (INIS)

    WAZER Alchemy 7b (WA-7b) is a WAZER calculation of a laser-driven micro-implosion of a spherical capsule consisting of a thin gold pusher surrounded by a thick (frozen) deuterium ablator. The properties of the target capsule and the shape of the laser pulse used to irradiate it are described

  1. Experimental modulation of capsule size in Cryptococcus neoformans

    Directory of Open Access Journals (Sweden)

    Zaragoza Oscar

    2004-01-01

    Full Text Available Experimental modulation of capsule size is an important technique for the study of the virulence of the encapsulated pathogen Cryptococcus neoformans. In this paper, we summarize the techniques available for experimental modulation of capsule size in this yeast and describe improved methods to induce capsule size changes. The response of the yeast to the various stimuli is highly dependent on the cryptococcal strain. A high CO2 atmosphere and a low iron concentration have been used classically to increase capsule size. Unfortunately, these stimuli are not reliable for inducing capsular enlargement in all strains. Recently we have identified new and simpler conditions for inducing capsule enlargement that consistently elicited this effect. Specifically, we noted that mammalian serum or diluted Sabouraud broth in MOPS buffer pH 7.3 efficiently induced capsule growth. Media that slowed the growth rate of the yeast correlated with an increase in capsule size. Finally, we summarize the most commonly used media that induce capsule growth in C. neoformans.

  2. Design of capsules capable of argon-filling

    International Nuclear Information System (INIS)

    The possibility of the use of polycarbosilane capsules as fuel container in inertial confinement fusion experiments was analyzed in the paper. Primary study indicates that the polycarbosilane capsules can be filled with argon by means of diffusion and possess reasonable retention time for deuterium. (author)

  3. Pars plana vitrectomy with posterior iris claw implantation for posteriorly dislocated nucleus and intraocular lens

    Directory of Open Access Journals (Sweden)

    Kishor B Patil

    2011-01-01

    Full Text Available We evaluated the safety and efficacy of pars plana vitrectomy (PPV with primary posterior iris claw intraocular lens (IOL implantation in cases of posterior dislocation of nucleus and IOL without capsular support. This was a retrospective interventional case series. Fifteen eyes underwent PPV with primary posterior iris claw IOL implantation performed by a single vitreoretinal surgeon. The main outcome measures were changes in best corrected visual acuity and anterior and posterior segment complications. A total of 15 eyes were included in this study. Eight had nucleus drop, three had IOL drop during cataract surgery and four had traumatic posterior dislocation of lens. The final postoperative best corrected visual acuity was 20/60 or better in 11 patients. This procedure is a viable option in achieving good functional visual acuity in eyes without capsular support.

  4. Analysis of Fission Products on the AGR-1 Capsule Components

    Energy Technology Data Exchange (ETDEWEB)

    Paul A. Demkowicz; Jason M. Harp; Philip L. Winston; Scott A. Ploger

    2013-03-01

    The components of the AGR-1 irradiation capsules were analyzed to determine the retained inventory of fission products in order to determine the extent of in-pile fission product release from the fuel compacts. This includes analysis of (i) the metal capsule components, (ii) the graphite fuel holders, (iii) the graphite spacers, and (iv) the gas exit lines. The fission products most prevalent in the components were Ag-110m, Cs 134, Cs 137, Eu-154, and Sr 90, and the most common location was the metal capsule components and the graphite fuel holders. Gamma scanning of the graphite fuel holders was also performed to determine spatial distribution of Ag-110m and radiocesium. Silver was released from the fuel components in significant fractions. The total Ag-110m inventory found in the capsules ranged from 1.2×10 2 (Capsule 3) to 3.8×10 1 (Capsule 6). Ag-110m was not distributed evenly in the graphite fuel holders, but tended to concentrate at the axial ends of the graphite holders in Capsules 1 and 6 (located at the top and bottom of the test train) and near the axial center in Capsules 2, 3, and 5 (in the center of the test train). The Ag-110m further tended to be concentrated around fuel stacks 1 and 3, the two stacks facing the ATR reactor core and location of higher burnup, neutron fluence, and temperatures compared with Stack 2. Detailed correlation of silver release with fuel type and irradiation temperatures is problematic at the capsule level due to the large range of temperatures experienced by individual fuel compacts in each capsule. A comprehensive Ag 110m mass balance for the capsules was performed using measured inventories of individual compacts and the inventory on the capsule components. For most capsules, the mass balance was within 11% of the predicted inventory. The Ag-110m release from individual compacts often exhibited a very large range within a particular capsule.

  5. Analysing intracellular deformation of polymer capsules using structured illumination microscopy

    Science.gov (United States)

    Chen, Xi; Cui, Jiwei; Sun, Huanli; Müllner, Markus; Yan, Yan; Noi, Ka Fung; Ping, Yuan; Caruso, Frank

    2016-06-01

    Understanding the behaviour of therapeutic carriers is important in elucidating their mechanism of action and how they are processed inside cells. Herein we examine the intracellular deformation of layer-by-layer assembled polymer capsules using super-resolution structured illumination microscopy (SIM). Spherical- and cylindrical-shaped capsules were studied in three different cell lines, namely HeLa (human epithelial cell line), RAW264.7 (mouse macrophage cell line) and differentiated THP-1 (human monocyte-derived macrophage cell line). We observed that the deformation of capsules was dependent on cell line, but independent of capsule shape. This suggests that the mechanical forces, which induce capsule deformation during cell uptake, vary between cell lines, indicating that the capsules are exposed to higher mechanical forces in HeLa cells, followed by RAW264.7 and then differentiated THP-1 cells. Our study demonstrates the use of super-resolution SIM in analysing intracellular capsule deformation, offering important insights into the cellular processing of drug carriers in cells and providing fundamental knowledge of intracellular mechanobiology. Furthermore, this study may aid in the design of novel drug carriers that are sensitive to deformation for enhanced drug release properties.Understanding the behaviour of therapeutic carriers is important in elucidating their mechanism of action and how they are processed inside cells. Herein we examine the intracellular deformation of layer-by-layer assembled polymer capsules using super-resolution structured illumination microscopy (SIM). Spherical- and cylindrical-shaped capsules were studied in three different cell lines, namely HeLa (human epithelial cell line), RAW264.7 (mouse macrophage cell line) and differentiated THP-1 (human monocyte-derived macrophage cell line). We observed that the deformation of capsules was dependent on cell line, but independent of capsule shape. This suggests that the mechanical forces

  6. 38 CFR 3.379 - Anterior poliomyelitis.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Anterior poliomyelitis. 3... Specific Diseases § 3.379 Anterior poliomyelitis. If the first manifestations of acute anterior poliomyelitis present themselves in a veteran within 35 days of termination of active military service, it...

  7. Relaxin Receptor RXFP1 and RXFP2 Expression in Ligament, Tendon, and Shoulder Joint Capsule of Rats.

    Science.gov (United States)

    Kim, Jae Hyung; Lee, Sang Kwang; Lee, Seong Kyu; Kim, Joo Heon; Fredericson, Michael

    2016-06-01

    Numerous musculoskeletal disorders are caused by thickened ligament, tendon stiffness, or fibrosis of joint capsule. Relaxin, a peptide hormone, can exert collagenolytic effect on ligamentous and fibrotic tissues. We hypothesized that local injection of relaxin could be used to treat entrapment neuropathy and adhesive capsulitis. Because hormonal effect depends on the receptor of the hormone on the target cell, it is important to confirm the presence of such hormonal receptor at the target tissue before the hormone therapy is initiated. The aim of this study was to determine whether there were relaxin receptors in the ligament, tendon, and joint capsular tissues of rats and to identify the distribution of relaxin receptors in these tissues. Transverse carpal ligaments (TCLs), inguinal ligaments, anterior cruciate ligaments (ACLs), Achilles tendons, and shoulder joint capsules were obtained from male Wistar rats. Western blot analysis was used to identify relaxin receptor isoforms RXFP1 and RXFP2. The distribution of relaxin receptors was determined by immunohistochemical staining. The RXFP1 isoform was found in all tissues examined. The RXFP2 isoform was present in all tissues but the TCLs. Its expression in ACLs tissues was relatively weak compared to that in other tissues. Our results revealed that RXFP1 and RXFP2 were distributed in distinctly different patterns according to the type of tissue (vascular endothelial cells, fibroblast-like cells) they were identified. PMID:27247510

  8. Epidermoid cyst in Anterior, Middle

    Directory of Open Access Journals (Sweden)

    Kankane Vivek Kumar

    2016-09-01

    Full Text Available Epidermoid cysts are benign slow growing more often extra-axial tumors that insinuate between brain structures, we present the clinical, imaging, and pathological findings in 35 years old female patients with atypical epidermoid cysts which was situated anterior, middle & posterior cranial fossa. NCCT head revealed hypodense lesion over right temporal and perisylvian region with extension in prepontine cistern with mass effect & midline shift and MRI findings revealed a non-enhancing heterogeneous signal intensity cystic lesion in right frontal & temporal region extending into prepontine cistern with restricted diffusion. Patient was detoriated in night of same day of admission, emergency Fronto-temporal craniotomy with anterior peterousectomy and subtotal resection was done. The histological examination confirms the epidermoid cyst. The timing of ectodermal tissue sequestration during fetal development may account for the occurrence of atypical epidermoid cysts.

  9. High-speed precision weighing of pharmaceutical capsules

    International Nuclear Information System (INIS)

    In this paper, we present a cost-effective method for fast and accurate in-line weighing of hard gelatin capsules based on the optimized capacitance sensor and real-time processing of the capsule capacitance profile resulting from 5000 capacitance measurements per second. First, the effect of the shape and size of the capacitive sensor on the sensitivity and stability of the measurements was investigated in order to optimize the performance of the system. The method was tested on two types of hard gelatin capsules weighing from 50 mg to 650 mg. The results showed that the capacitance profile was exceptionally well correlated with the capsule weight with the correlation coefficient exceeding 0.999. The mean precision of the measurements was in the range from 1 mg to 3 mg, depending on the size of the capsule and was significantly lower than the 5% weight tolerances usually used by the pharmaceutical industry. Therefore, the method was found feasible for weighing pharmaceutical hard gelatin capsules as long as certain conditions are met regarding the capsule fill properties and environment stability. The proposed measurement system can be calibrated by using only two or three sets of capsules with known weight. However, for most applications it is sufficient to use only empty and nominally filled capsules for calibration. Finally, a practical application of the proposed method showed that a single system is capable of weighing around 75 000 capsules per hour, while using multiple systems could easily increase the inspection rate to meet almost any requirements

  10. Anterior impingement syndrome in dancers

    OpenAIRE

    O’Kane, John William; Kadel, Nancy

    2007-01-01

    Anterior impingement is a common problem in dancers occurring primarily secondary to the repetitive forced ankle dorsiflexion inherent in ballet. Symptoms generally occur progressively and may respond to conservative treatment including addressing biomechanical faults that contribute to the problem. As impingement progresses, movements essential to ballet may become impossible and arthroscopic ankle surgery is often effective for both diagnosis and treatment, allowing athletes to return to da...

  11. RAMA Surveillance Capsule and Component Activation Analyses

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, Kenneth E.; Jones, Eric N. [TransWare Enterprises Inc., 1565 Mediterranean Dr., Sycamore, IL 60178 (United States); Carter, Robert G. [Electric Power Research Institute, 1300 West W. T. Harris Blvd., Charlotte, NC 28262 (United States)

    2011-07-01

    This paper presents the calculated-to-measured ratios associated with the application of the RAMA Fluence Methodology software to light water reactor surveillance capsule and reactor component activation evaluations. Comparisons to measurements are performed for pressurized water reactor and boiling water reactor surveillance capsule activity specimens from seventeen operating light water reactors. Comparisons to measurements are also performed for samples removed from the core shroud, top guide, and jet pump brace pads from two reactors. In conclusion: The flexible geometry modeling capabilities provided by RAMA, combined with the detailed representation of operating reactor history and anisotropic scattering detail, produces accurate predictions of the fast neutron fluence and neutron activation for BWR and PWR surveillance capsule geometries. This allows best estimate RPV fluence to be determined without the need for multiplicative bias corrections. The three-dimensional modeling capability in RAMA provides an accurate estimate of the fast neutron fluence for regions far removed from the core mid-plane elevation. The comparisons to activation measurements for various core components indicate that the RAMA predictions are reasonable, and notably conservative (i.e., C/M ratios are consistently greater than unity). It should be noted that in the current evaluations, the top and bottom fuel regions are represented by six inch height nodes. As a result, the leakage-induced decrease in power near the upper and lower edges of the core are not well represented in the current models. More precise predictions of fluence for components that lie above and below the core boundaries could be obtained if the upper and lower fuel nodes were subdivided into multiple axial regions with assigned powers that reflect the neutron leakage at the top and bottom of the core. This use of additional axial sub-meshing at the top and bottom of the core is analogous to the use of pin

  12. Update and clinical utility of the LenSx femtosecond laser in cataract surgery

    Science.gov (United States)

    Roberts, Timothy V; Lawless, Michael; Sutton, Gerard; Hodge, Chris

    2016-01-01

    The introduction of femtosecond lasers to cataract surgery has been the major disruptive technology introduced into ophthalmic surgery in the last decade. Femtosecond laser cataract surgery (FLACS) integrates high-resolution anterior segment imaging with a femtosecond laser allowing key steps of cataract surgery to be performed with computer-guided laser accuracy, precision, and reproducibility. Since the introduction of FLACS, there have been significant advances in laser software and hardware as well as surgeon experience, with over 250 articles published in the peer-reviewed literature. This review examines the published evidence relating to the LenSx platform and discusses surgical techniques, indications, safety, and clinical results.

  13. The Clinical Analysis of Secondary Glaucoma Following Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    We present 14 patients with secondary gluacoma following the implantation of a posterior chamber intraocular lens (lOLs). All patients were u-nilateral gluacoma , which developed within 1 month following the IOL implantation in 10 cases, and from 1 to 3 years in 4 cases. The angle of anterior chamber was open in 8 patients, and close in 6 ones. Seven patients required treatment of antiglaucomatous medicine; 4 patients underwent laser indecto-my and 3 patients required antiglaucoma surgery. The results s...

  14. Fungal endophthalmitis caused by Paecilomyces variotii, in an immunocompetent patient, following intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Anita K

    2010-01-01

    Full Text Available We report the case of a 70-year-old man who was admitted for anterior endophthalmitis following an intraocular lens implantation. He had developed a fluffy growth resembling a fungal mass on the iris of the right eye. The mass was removed and sent for fungal studies to our department. Direct microscopy revealed hyphae. Further studies helped identify the fungus to belong to genus Paecilomyces. This is a rare case of fungal endophthalmitis caused by Paecilomyces variotii in an immunocompetent person.

  15. Expression analysis of genes involved in collagen cross-linking and its regulation in traumatic anterior shoulder instability.

    Science.gov (United States)

    Belangero, Paulo Santoro; Leal, Mariana Ferreira; Cohen, Carina; Figueiredo, Eduardo Antônio; Smith, Marília Cardoso; Andreoli, Carlos Vicente; de Castro Pochini, Alberto; Ejnisman, Benno; Cohen, Moises

    2016-03-01

    The molecular alterations involved in the capsule deformation presented in shoulder instability patients are poorly understood. Increased TGFβ1 acts as a signal for production of matrix macromolecules by fibrogenic cells at joint injury sites. TGFβ1, through its receptor TGFβR1, regulates genes involved in collagen cross-linking, such as LOX, PLOD1, and PLOD2. We evaluated TGFβ1, TGFβR1, LOX, PLOD1, and PLOD2 gene expression in the antero-inferior (macroscopically injured region), antero-superior and posterior regions of the glenohumeral capsule of 29 shoulder instability patients and eight controls. We observed that PLOD2 expression was increased in the anterior-inferior capsule region of the patients compared to controls. LOX expression tended to be increased in the posterior portion of patients. Patients with recurrent shoulder dislocation presented upregulation of TGFβR1 in the antero-inferior capsule portion and of PLOD2 in the posterior region. Conversely, LOX was increased in the posterior portion of the capsule of patients with a single shoulder dislocation episode. In the antero-inferior, LOX expression was inversely correlated and TGFβR1 was directly correlated with the duration of symptoms. In the posterior region, PLOD2, TGFβ1, and TGFβR1 were directly correlated with the duration of symptoms. In conclusion, PLOD2 expression was increased in the macroscopically injured region of the capsule of patients. Upregulation of TGFβ1, TGFβR1, and PLOD2 seems to be related with the maintenance of disease symptoms, especially in the posterior region. LOX upregulation seems to occur only in the initial phase of the affection. Therefore, TGFβ1, TGFβR1, LOX, and PLOD2 may play a role in shoulder instability. PMID:26185036

  16. A comparative study on liquid core formulation on the diameter on the alginate capsules

    Science.gov (United States)

    Ong, Hui-Yen; Lee, Boon-Beng; Radzi, AkmalHadi Ma'; Zakaria, Zarina; Chan, Eng-Seng

    2015-08-01

    Liquid core capsule has vast application in biotechnology related industries such as pharmaceutical, medical, agriculture and food. Formulation of different types of capsule was important to determine the performance of the capsule. Generally, the liquid core capsule with different formulations generated different size of capsule.Therefore, the aim of this project is to investigate the effect of different liquid core solution formulations on the diameter of capsule. The capsule produced by extruding liquid core solutions into sodium alginate solution. Three types of liquid core solutions (chitosan, xanthan gum, polyethylene glycol (PEG)) were investigated. The results showed that there is significant change in capsule diameter despite in different types of liquid core solution were used and a series of capsule range in diameter of 3.1 mm to 4.5 mm were produced. Alginate capsule with chitosan formulation appeared to be the largest capsule among all.

  17. Vortex Rings from Sphagnum Moss Capsules

    CERN Document Server

    Chang, Emily S; Cha, Jung Ha; Strassman, Sam; Hard, Clara; Whitaker, Dwight L

    2010-01-01

    Long distance wind dispersal requires small spores with low terminal velocities, which can be held aloft by turbulent air currents until they are deposited in suitable habitats for colonization. The inherent difficulty in dispersing spores by wind is that spores easily carried by wind are also rapidly decelerated when moving through still air. Thus the height of spore release is critical in determining their range of dispersal. Vascular plants with wind dispersed spores use the height of the plant to lift spores into sufficient wind currents for dispersal, however non-vascular plants such as Sphagnum cannot grow sufficiently tall. These fluid dynamics videos show how exploding capsules of {\\em Sphagnum} moss generate vortex rings to carry spores to heights above 10 cm with an initial velocity of 16 m s$^{-1}$. In contrast spores launched ballistically at these speeds through still air would travel only 2-7 mm.

  18. Optimal Bowel Preparation for Video Capsule Endoscopy

    Directory of Open Access Journals (Sweden)

    Hyun Joo Song

    2016-01-01

    Full Text Available During video capsule endoscopy (VCE, several factors, such as air bubbles, food material in the small bowel, and delayed gastric and small bowel transit time, influence diagnostic yield, small bowel visualization quality, and cecal completion rate. Therefore, bowel preparation before VCE is as essential as bowel preparation before colonoscopy. To date, there have been many comparative studies, consensus, and guidelines regarding different kinds of bowel cleansing agents in bowel preparation for small bowel VCE. Presently, polyethylene glycol- (PEG- based regimens are given primary recommendation. Sodium picosulphate-based regimens are secondarily recommended, as their cleansing efficacy is less than that of PEG-based regimens. Sodium phosphate as well as complementary simethicone and prokinetics use are considered. In this paper, we reviewed previous studies regarding bowel preparation for small bowel VCE and suggested optimal bowel preparation of VCE.

  19. A comparative study of two types of implantable lenses for correcting high myopia: A posterior chamber phakic refractive lens and a collamer lens%两种有晶状体眼后房型人工晶状体矫正高度近视的远期疗效

    Institute of Scientific and Technical Information of China (English)

    陆勤义; 廖荣丰; 夏卫东; 喻珺琦; 夏春丽; 费孝庆

    2014-01-01

    Objective To compare the clinical efficacy of two types of implantable lenses:a posterior chamber phakic refractive lens (PC-PRL) and a phakic posterior chamber implantable collamer lens (PPC-ICL) in two groups of patients with high myopia.Methods This was a retrospective study.Ninety-eight myopic eyes of 51 high myopia patients were enrolled.Eighteen patients (33 eyes) were implanted with PC-PRLs (PRL group),and the other 33 patients (65 eyes) were implanted with PPC-ICLs (ICL group).Visual acuity,mainfest refraction,intraocular pressure,endothelial cell density,the distance between the posterior surface of the cornea to the lens,and contrast sensitivity (CS) were measured at least 2 years after the surgery.The occurrence of complications was also observed in the patients.An independent samples t test and Wilcoxon rank sum test were used for statistical analysis.Results A comparison of uncorrected visual acuity after surgery between the PRL and ICL groups did not show a significant difference (Z=-1.871,P>0.05).Intraocular pressure was 12.03±2.61 mmHg in the PRL group and 13.35±3.37 mmHg in the ICL group (t=-1.197,P>0.05),while endothelial cell density was 2 185±516 cells/mm2 in the PRL group and 2 341±405 cells/mm2 in the ICL group (t=-1.168,P>0.05).There was no significant difference in a comparison of the distance between the posterior surface of the cornea to the lens,nor was there a significant difference between the arc height of 0.37±0.15 mm in the PRL group and 0.41±0.17 mm in the ICL group (t=-1.120,P>0.05).In addition,there was no significant difference in CS at all spatial frequencies.In terms of complications,in the PRL group,the lens deviated in 1 patient (1 eye) and cataract developed in 1 patient (1 eye); in the ICL group,a cataract developed in 1 patient (2 eyes) and posterior surface artificial crystals came in contact with the anterior surface of the lens which added to the opacity of the anterior capsule in 1 patient (2 eyes

  20. Bilateral Superior Labrum Anterior to Posterior (SLAP) Tears With Abnormal Anatomy of Biceps Tendon.

    Science.gov (United States)

    Morris, Dan; Guettler, Joseph; Morris, Sean

    2015-08-01

    There have been several descriptions of variant anatomy of the long head of the biceps tendon (LHBT). A recent literature review identified 8 cases of anomalous intracapsular attachment of the LHBT. In this report, we discuss a distinctive case of a young athlete who presented with symptoms consistent with bilateral superior labrum anterior to posterior (SLAP) tears that were unresponsive to conservative measures. Magnetic resonance imaging and arthroscopic findings of this patient confirmed that the patient had type II SLAP tears, a Buford complex anteriorly, and perhaps most important, confluence of the biceps tendon itself to the undersurface of the capsule within the rotator interval. Our case proposes that anomalous insertion of the LHBT, as well as other labral and biceps anchor variations, are not always a benign finding at the time of arthroscopy. In this particular case, the tethering of the biceps tendon to the capsule is thought to have increased stress on the superior labrum and contributed to the development of the bilateral symptomatic type II SLAP tears that were identified and treated in this young athlete.

  1. Conjugate metamaterials and the perfect lens

    CERN Document Server

    Xu, Yadong; Xu, Lin; Chen, Huanyang

    2015-01-01

    In this letter, we show how transformation optics makes it possible to design what we call conjugate metamaterials. We show that these materials can also serve as substrates for making a subwavelength-resolution lens. The so-called "perfect lens", which is a lens that could focus all components of light (including propagating and evanescent waves), can be regarded as a limiting case, in which the respective conjugate metamaterials approach the characteristics of left-handed metamaterials, which have a negative refractive index.

  2. Adhesion and detachment of a capsule in axisymmetric flow

    Science.gov (United States)

    Keh, M. P.; Leal, L. G.

    2016-05-01

    The adhesion and detachment of a capsule on a solid boundary surface is studied via a combination of scaling theory and numerical simulation and the behavior is compared and contrasted with a vesicle. It is shown that the dominant physical property for both capsules and vesicles is the area dilation modulus Ks of the membrane. The nonzero shear modulus Gs for capsules increases the resistance to deformation and thus decreases slightly the equilibrium contact radius for an adhered capsule compared to an adhered vesicle. The detachment process in this study is due to an external axisymmetric flow. Unlike a rigid body that must be pulled away without change of shape, capsules (and vesicles) almost always detach dominantly by peeling in which the contact radius decreases but the minimum separation distance does not change until the final moments of detachment. Compared to a vesicle with the same Ks, a capsule maintains a more compact shape and is harder to elongate under a given external flow. Hence, the detachment process is slower for capsules compared to vesicles with the same Ks.

  3. In vitro study on sustained release capsule formulation of acetazolamide.

    Science.gov (United States)

    Pandey, V P; Kannan, K; Manavalan, R; Desai, N

    2003-10-01

    In the present study formulation of sustained release capsule of acetazolamide 250 mg was tried using nonpareil seeds. Nonpareil seeds were coated with drug, polyvinylpyrrolidone, glyceryl monostearate, microcrystalline wax, and glyceryl distearate either individually or in combination to achieve sustained release capsule 250 mg. In successful formulation 20% drug coated pellets and 80% wax coated pellets were taken. Wax coated pellets for successful formulation contained coating of microcrystalline wax and glyceryl distearate on drug coated pellets of the same concentration of 1.6% w/w. Successful formulated sustained release capsule 250 mg of acetazolamide was compared in in vitro study with theoretical sustained release formulation suggested by wagner and one marketed sustained release capsule 250 mg. Formulated capsule showed result superior to or on par with marketed capsule. For successful formulation pellets were filled in '1' size hard gelatin capsule and stability study was carried out in hot air over at room temperature and 45 degrees C for 5 weeks. The formulation was found stable in respect of drug content and release rate.

  4. Patency(C) and agile(C) capsules

    Institute of Scientific and Technical Information of China (English)

    àngel Caunedo-àlvarez; Javier Romero-Vazquez; Juan M Herrerias-Gutierrez

    2008-01-01

    Small bowel strictures can be missed by current diagnostic methods.The Patency capsule is a new non-endoscopic dissolvable capsule which has as an objective of checking the patency of digestive tract,in a non-invasive manner.The available clinical trials have demonstrated that the Patency(C) capsule is a good tool for assessment of the functional patency of the small bowel,and it allows identification of those patients who can safely undergo a capsule endoscopy,despite clinical and radiographic evidence of small-bowel obstruction.Some cases of intestinal occlusion have been reported with the Patency(C) capsule,four of them needed surgery.So,a new capsule with two timer plugs (Agile(C) capsule) has been recently developed in order to minimize the risk of occlusion.This new device stars its dissolution process earlier (30 h after ingestion) and its two timer plugs have been designed to begin the disintegration even when the device is blocked in a tight stricture.

  5. 16 CFR 315.6 - Expiration of contact lens prescriptions.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Expiration of contact lens prescriptions... CONGRESS CONTACT LENS RULE § 315.6 Expiration of contact lens prescriptions. (a) In general. A contact lens... Commission, its employees, and its representatives. (3) No prescriber shall include an expiration date on...

  6. Bionic intraocular lens with variable focus and integrated structure

    Science.gov (United States)

    Liang, Dan; Wang, Xuan-Yin; Du, Jia-Wei; Xiang, Ke

    2015-10-01

    This paper proposes a bionic accommodating intraocular lens (IOL) for ophthalmic surgery. The designed lens has a solid-liquid mixed integrated structure, which mainly consists of a support ring, elastic membrane, rigid lens, and optical liquid. The lens focus can be adjusted through the deformation of the lens front surface when compressed. The integrated structure of the IOL is presented, as well as a detailed description of the lens materials and fabrication process. Images under different radial pressures are captured, and the lens deformation process, accommodating range, density, and optical property are analyzed. The designed lens achieves a 14.6 D accommodating range under a radial pressure of 51.4 mN and a 0.24 mm alteration of the lens outer radius. The deformation property of the lens matches well with the characteristic of the eye and shows the potential to help patients fully recover their vision accommodation ability after the cataract surgery.

  7. RISK FACTORS FOR CONTACT LENS INDUCED PAPILLARY CONJUNCTIVITIS ASSOCIATED WITH SILICONE HYDROGEL CONTACT LENS WEAR

    Science.gov (United States)

    Tagliaferri, Angela; Love, Thomas E.; Szczotka-Flynn, Loretta

    2014-01-01

    BACKGROUND Contact lens induced papillary conjunctivitis (CLPC) continues to be a major cause of dropout during contact lens extended wear. This retrospective study explores risk factors for the development of CLPC during silicone hydrogel lens extended wear. METHODS Data from 205 subjects enrolled in the Longitudinal Analysis of Silicone Hydrogel Contact Lens (LASH) study wearing lotrafilcon A silicone hydrogel lenses for up to 30 days of continuous wear were used to determine risk factors for CLPC in this secondary analysis of the main cohort. The main covariates of interest included substantial lens-associated bacterial bioburden, and topographically determined lens base curve-to-cornea fitting relationships. Additional covariates of interest included history of prior adverse events, time of year, race, education level, gender and other subject demographics. Statistical analyses included univariate logistic regression to assess the impact of potential risk factors on the binary CLPC outcome, and Cox proportional hazards regression to describe the impact of those factors on time-to-CLPC diagnosis. RESULTS Across 12 months of follow-up, 52 subjects (25%) experienced CLPC. No associations were found between CLPC development and the presence of bacterial bioburden, lens-to-cornea fitting relationships, history of prior adverse events, gender or race. CLPC development followed the same seasonal trends as the local peaks in environmental allergans. CONCLUSIONS Lens fit and biodeposits, in the form of lens associated bacterial bioburden, were not associated with the development of CLPC during extended wear with lotrafilcon A silicone hydrogel lenses. PMID:24681609

  8. Methane Detector With Plastic Fresnel Lens

    Science.gov (United States)

    Grant, W. B.

    1986-01-01

    Laser detector for natural gas leaks modified by substitution of molded plastic lens for spherical mirror. By measuring relative attenuation at two wavelengths, detector used to check for methane escaping from pipelines above or below ground and from landfill.

  9. Role of Aquaporin 0 in lens biomechanics

    Energy Technology Data Exchange (ETDEWEB)

    Sindhu Kumari, S.; Gupta, Neha [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Shiels, Alan [Washington University School of Medicine, St. Louis, MO (United States); FitzGerald, Paul G. [Cell Biology and Human Anatomy, School of Medicine, University of California, Davis, CA (United States); Menon, Anil G. [University of Cincinnati College of Medicine, Cincinnati, OH (United States); Mathias, Richard T. [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States)

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and

  10. Design and synthesis of organic-inorganic hybrid capsules for biotechnological applications.

    Science.gov (United States)

    Shi, Jiafu; Jiang, Yanjun; Wang, Xiaoli; Wu, Hong; Yang, Dong; Pan, Fusheng; Su, Yanlei; Jiang, Zhongyi

    2014-08-01

    Organic-inorganic hybrid capsules, which typically possess a hollow lumen and a hybrid wall, have emerged as a novel and promising class of hybrid materials and have attracted enormous attention. In comparison to polymeric capsules or inorganic capsules, the hybrid capsules combine the intrinsic physical/chemical properties of the organic and inorganic moieties, acquire more degrees of freedom to manipulate multiple interactions, create hierarchical structures and integrate multiple functionalities. Thus, the hybrid capsules exhibit superior mechanical strength (vs. polymeric capsules) and diverse functionalities (vs. inorganic capsules), which may give new opportunities to produce high-performance materials. Much effort has been devoted to exploring innovative and effective methods for the synthesis of hybrid capsules that exhibit desirable performance in target applications. This tutorial review firstly presents a brief description of the capsular structure and hybrid materials in nature, then classifies the hybrid capsules into molecule-hybrid capsules and nano-hybrid capsules based upon the size of the organic and inorganic moieties in the capsule wall, followed by a detailed discussion of the design and synthesis of the hybrid capsules. For each kind of hybrid capsule, the state-of-the-art synthesis methods are described in detail and a critical comment is embedded. The applications of these hybrid capsules in biotechnological areas (biocatalysis, drug delivery, etc.) have also been summarized. Hopefully, this review will offer a perspective and guidelines for the future research and development of hybrid capsules.

  11. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens

    Science.gov (United States)

    Faria, Mun Yueh; Ferreira, Nuno Pinto; Pinto, Joana Medeiros; Sousa, David Cordeiro; Leal, Ines; Neto, Eliana; Marques-Neves, Carlos

    2016-01-01

    Background Nowadays, dislocated intraocular lenses (IOLs) and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL) are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL. Methods This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth. Results The mean follow-up was 23 months (range: 6–48 months). The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1) retinal detachment was found in one patient, 2) corneal edema was found in three patients, 3) high intraocular pressure was observed in twelve patients, 4) subluxation of the IOL was observed in one patient, and 5) macular edema was found in three eyes. Conclusion The results demonstrate that retropupillary ICIOL is an easy and effective method for the correction of aphakia in patients not receiving capsule support. The safety of this procedure must be interpreted in the context

  12. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens

    Directory of Open Access Journals (Sweden)

    Faria MY

    2016-08-01

    Full Text Available Mun Yueh Faria,1–3 Nuno Pinto Ferreira,1–3 Joana Medeiros Pinto,1–3 David Cordeiro Sousa,1–3 Ines Leal,1–3 Eliana Neto,1–3 Carlos Marques-Neves1–3 1Centro de Estudos da Visão, Universidade de Lisboa, 2Department of Ophthalmology, Hospital de Santa Maria, 3Faculty of Medicine, University of Lisbon, Lisbon, Portugal Background: Nowadays, dislocated intraocular lenses (IOLs and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL.Methods: This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth.Results: The mean follow-up was 23 months (range: 6–48 months. The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1 retinal detachment was found in one patient, 2 corneal edema was found in three patients, 3 high intraocular pressure was observed in

  13. A Spectrometer Based on Diffractive Lens

    Institute of Scientific and Technical Information of China (English)

    WANG Daoyi; YAN Yingbai; JIN Guofan; WU Minxian

    2001-01-01

    A novel spectrometer is designed based on diffractive lens. It is essentially a flat field spectrometer. All the focal points are along the optical axis. Besides, all the asymmetrical aberrations vanish in our mounting. Thus low aberration can be obtained. In this article a diffractive lens is modeled as a special grating and analyzed by using a grating-based method. And a stigmatic point is introduced to reduce the aberrations.

  14. Environmental standards for intraocular lens implantation.

    Science.gov (United States)

    Crawford, B A; Kaufman, D V

    1984-02-01

    Successful implantation of prosthetic devices depends upon their freedom from postoperative inflammation and infection. Techniques and lessons learned in orthopaedic and other implant surgery should be applied to intraocular lens implantation. The avoidance of contamination by particles and micro-organisms is one essential principle of the surgical procedure. Practical steps are described to reduce both types of contamination. These measures taken together are recommended for adoption as a standard of environmental safety for lens implantation.

  15. Bilateral Pseudoexfoliation Deposits on Intraocular Lens Implants

    OpenAIRE

    Elena Bonafonte Marquez; Sergio Bonafonte Royo

    2015-01-01

    We present a rare case of bilateral pseudoexfoliative deposits on both intraocular lens (IOL) implants in an 83-year-old woman with no other associated pathology, 5 years after cataract surgery. Pseudoexfoliation syndrome is the most common cause of secondary open-angle glaucoma worldwide and these deposits are usually found on the natural lens. The fact that pseudoexfoliative deposits have been found on IOL implants implies the need for a thorough examination in pseudophakic patients, for i...

  16. Introduction to the development of intraocular lens

    Science.gov (United States)

    Li, Yifan; Peng, Runling; Hu, Shuilan; Wei, Maowei; Chen, Jiabi

    2013-08-01

    In order to cure the cataract disease or injuries in eyes, intraocular lens(IOL) has been studied all the time to replace the crystalline lens in human eyes. Researches on IOL are started early from 19th century, and it develops greatly in the hundreds years after. This article introduces several main kinds of IOLs that appear in the development history of IOL, and raises the double-liquid zoom IOL based on electrowetting, which will be the trend of IOL study.

  17. Responses of the Ocular Anterior Segment and Refraction to 0.5% Tropicamide in Chinese School-Aged Children of Myopia, Emmetropia, and Hyperopia

    Directory of Open Access Journals (Sweden)

    Ying Yuan

    2015-01-01

    Full Text Available Purpose. To investigate the changes of anterior segment after cycloplegia and estimate the association of such changes with the changes of refraction in Chinese school-aged children of myopia, emmetropia, and hyperopia. Methods. 309 children were recruited and eligible subjects were assigned to three groups: hyperopia, emmetropia, or myopia. Cycloplegia was achieved with five cycles of 0.5% tropicamide. The Pentacam system was used to measure the parameters of interest before and after cycloplegia. Results. In the myopic group, the lenses were thinner and the lens position was significantly more posterior than that of the emmetropic and hyperopic groups in the cycloplegic status. The correlations between refraction and lens thickness (age adjusted; r=0.26, P<0.01, and lens position (age adjusted; r=-0.31, P<0.01 were found. After cycloplegia, ACD and ACV significantly increased, while ACA significantly decreased. Changes in refraction, ACD, ACV, and ACA were significantly different among the three groups (P<0.05, all. Changes of refraction were correlated with changes of ACD (r=0.41, P<0.01. Conclusions. Myopia presented thinner lenses and smaller changes of anterior segment and refraction after cycloplegia when compared to emmetropia and hyperopia. Changes of anterior chamber depth were correlated with refraction changes. This may contribute to a better understanding of the relationship between anterior segment and myopia.

  18. Photon nanojet lens: design, fabrication and characterization

    Science.gov (United States)

    Xu, Chen; Zhang, Sichao; Shao, Jinhai; Lu, Bing-Rui; Mehfuz, Reyad; Drakeley, Stacey; Huang, Fumin; Chen, Yifang

    2016-04-01

    In this paper, a novel nanolens with super resolution, based on the photon nanojet effect through dielectric nanostructures in visible wavelengths, is proposed. The nanolens is made from plastic SU-8, consisting of parallel semi-cylinders in an array. This paper focuses on the lens designed by numerical simulation with the finite-difference time domain method and nanofabrication of the lens by grayscale electron beam lithography combined with a casting/bonding/lift-off transfer process. Monte Carlo simulation for injected charge distribution and development modeling was applied to define the resultant 3D profile in PMMA as the template for the lens shape. After the casting/bonding/lift-off process, the fabricated nanolens in SU-8 has the desired lens shape, very close to that of PMMA, indicating that the pattern transfer process developed in this work can be reliably applied not only for the fabrication of the lens but also for other 3D nanopatterns in general. The light distribution through the lens near its surface was initially characterized by a scanning near-field optical microscope, showing a well defined focusing image of designed grating lines. Such focusing function supports the great prospects of developing a novel nanolithography based on the photon nanojet effect.

  19. Awful face of the war-impacted smoke bomb capsule in the face and systemic toxicity: reports from the conflict in Syria.

    Science.gov (United States)

    Yilmaz, Bahar; Yeşiloğlu, Nebil; Firincioğullari, Remzi; Gökkaya, Ali; Özbey, Rafet; Özgür, Mustafa

    2015-01-01

    In this study, a rare kind of injury due to smoke bomb capsule impaction to midface and under the cranial base is presented, and maneuvers to reduce mortality are discussed. Three male patients were presented with impacted smoke bomb capsules into the midface and under the cranial base structures. Midface structures, anterior cranial base, and, in 2 patients, unilateral eye were severely damaged. Two patients died after the initial emergency operations because their lung disease progressed to acute respiratory distress syndrome. One of the patients lived, and soft tissue reconstruction was achieved by using temporal transposition and cheek advancement skin flaps with split-thickness skin graft from donor site. However, craniofacial destruction is important in these patients; a multidisciplinary approach is needed for the treatment of direct smoke bomb injuries because the patients experienced chemical burn and acute trauma. The timing of maxillofacial reconstruction is also a question in these specific patients.

  20. Cataract phacoemulsification with intraocular lens implantation after keratoprosthetics by Burn Vascular Leukoma (A case report

    Directory of Open Access Journals (Sweden)

    E.V. Kovshun,

    2014-01-01

    Full Text Available ABSTRACT Purpose. To evaluate the phacoemulsification (Phaco with intraocular lens (IOL implantation outcome after keratoprosthetics in patient with burn vascular leukoma. Material and methods. A patient, 39 years old, with a thinned burn vascular leukoma as a result of burns, limbal stem cell deficiency of both eyes, local simblefaron in the left eye (OS, secondary glaucoma (OS, after a simblefaron dissection and a glaucoma operation (OS, it was performed keratoprosthetics with a undismountable model of keratoprosthesis with an improvement in visual acuity (VA from 1/∞ рr. сerta up to 0.5 u/c. But there was a decrease in the VA to 0.01 u/c in 13 months. The aglia with vascularization and total overgrowth on the conjunctiva were observed on admission. Haptic keratoprostheses elements were not visible. Optical cylinder was clear. Anterior chamber depth was less than the average. A pronounced opacity of cortical layers of crystalline lens were defined. Fundus details were not visualized. A disturbance of topographic anatomical correlations in all structures of the anterior segment of the eye (ASE was revealed by the ultrasound bio-microscopy: corneal thickness — 1.47mm, anterior chamber depth in the central parts — 1.09mm, а lot of irido-corneal adhesions in the anterior chamber angle (ACA with anterior chamber closing by basal area of the iris, medium hypertrophy of the iris (0.43mm. The maximum size of the ciliary body was 0.74mm. Ciliary zonule fibers were heterogeneous: in three segments they were thickened, hypertrophied and with adhesions between them, in one segment lysed or fused with the iris. Posterior chamber dimensions were acutely asymmetrical. Anterior posterior size of lens w as 5.23mm. Despite the significant impairments of spatial relations in ASE structures in the patient the microinvasive Phaco with soft IOL implantation were carried out with the preventive purpose of possible complications during the highly traumatic

  1. Anterior chest wall examination reviewed

    Directory of Open Access Journals (Sweden)

    F. Trotta

    2011-09-01

    Full Text Available Anterior chest wall involvement is not infrequently observed within inflammatory arthropaties, particularly if one considers seronegative spondiloarthritides and SAPHO syndrome. Physical examination is unreliable and conventional X-rays analysis is an unsatisfactory tool during diagnostic work-up of this region. Scintigraphic techniques yield informations both on the activity and on the anatomical extent of the disease while computerized tomography visualize the elementary lesions, such as erosions, which characterize the process. Moreover, when available, magnetic resonance imaging couple the ability to finely visualize such lesions with the possibility to show early alterations and to characterize the “activity” of the disease, presenting itself as a powerful tool both for diagnosis and follow-up. This review briefly shows the applications of imaging techniques for the evaluation of the anterior chest wall focusing on what has been done in the SAPHO syndrome which can be considered prototypical for this regional involvement since it is the osteo-articular target mainly affected by the disease.

  2. Nanoparticle-Stabilized Capsules for the Treatment of Bacterial Biofilms.

    Science.gov (United States)

    Duncan, Bradley; Li, Xiaoning; Landis, Ryan F; Kim, Sung Tae; Gupta, Akash; Wang, Li-Sheng; Ramanathan, Rajesh; Tang, Rui; Boerth, Jeffrey A; Rotello, Vincent M

    2015-08-25

    Bacterial biofilms are widely associated with persistent infections. High resistance to conventional antibiotics and prevalent virulence makes eliminating these bacterial communities challenging therapeutic targets. We describe here the fabrication of a nanoparticle-stabilized capsule with a multicomponent core for the treatment of biofilms. The peppermint oil and cinnamaldehyde combination that comprises the core of the capsules act as potent antimicrobial agents. An in situ reaction at the oil/water interface between the nanoparticles and cinnamaldehyde structurally augments the capsules to efficiently deliver the essential oil payloads, effectively eradicating biofilms of clinically isolated pathogenic bacteria strains. In contrast to their antimicrobial action, the capsules selectively promoted fibroblast proliferation in a mixed bacteria/mammalian cell system making them promising for wound healing applications. PMID:26083534

  3. Wireless capsule video endoscopy:Three years of experience

    Institute of Scientific and Technical Information of China (English)

    Rami Eliakim

    2004-01-01

    AIM: To review and summerize the current literatue regarding M2A wireless capsule endoscopy.METHODS: Peer reviewed publications regarding the use of capsule endoscopy as well as our personal experience were reviewed.RESULTS: Review of the literature dearly showed that capsule endoscopy was superior to enteroscopy, small bowel follow through and computerized tomography in patients with obscure gastrointestinal bleeding, iron deficiency anemia,or suspected Crohn′s disease. It was very sensitive for the diagnosis of small bowel tumors and for survailance of small bowel pathology in patients with Gardner syndrome or familial adenomatous polyposis syndrome. Its role in celiac disease and in patients with known Crohn′s disease was currently being investigated.CONCLUSION: Capsule video endoscopy is a superior and more sensitive diagnostic tool than barium follow through,enteroscopy and entero- CT in establishing the diagnosis of many small bowel pathologies.

  4. Diamagnetically-stabilized levitation control of an intraluminal magnetic capsule.

    Science.gov (United States)

    Lam, Michael; Mintchev, Martin P

    2008-01-01

    Controlled navigation promotes full utilization of capsule endoscopy for reliable real-time diagnosis in the gastrointestinal (GI) tract, but intermittent natural peristalsis can disturb the navigational control, destabilize the capsule and take it out of levitation. A real-size magnetic navigation system that can handle peristaltic forces of up to 1.5 N was designed utilizing the computer-aided design (CAD) system Maxwell 3D (Ansoft, Pittsburg, PA), and was verified using a small-size physical experimental setup. The proposed system contains a pair of 50-cm in diameter, 10,000-turns copper electromagnets with a 10-cm by 10-cm ferrous core driven by currents of up to 300 Amperes and can successfully maintain position control over the levitating capsule during peristalsis. The addition of Bismuth diamagnetic casing for stabilizing the levitating capsule was also studied. PMID:19163990

  5. Capsule endoscopy of the future: What's on the horizon?

    Science.gov (United States)

    Slawinski, Piotr R; Obstein, Keith L; Valdastri, Pietro

    2015-10-01

    Capsule endoscopes have evolved from passively moving diagnostic devices to actively moving systems with potential therapeutic capability. In this review, we will discuss the state of the art, define the current shortcomings of capsule endoscopy, and address research areas that aim to overcome said shortcomings. Developments in capsule mobility schemes are emphasized in this text, with magnetic actuation being the most promising endeavor. Research groups are working to integrate sensor data and fuse it with robotic control to outperform today's standard invasive procedures, but in a less intrusive manner. With recent advances in areas such as mobility, drug delivery, and therapeutics, we foresee a translation of interventional capsule technology from the bench-top to the clinical setting within the next 10 years.

  6. 21 CFR 520.1803 - Piperazine citrate capsules.

    Science.gov (United States)

    2010-04-01

    .... (c) Conditions of use. (1) It is used in dogs and cats for the removal of large roundworms (Toxocara canis and Toxascaris leonina). (2) The contents of 1 capsule should be mixed with the food of the...

  7. OUTCOME OF PHACOEMULSIFICATION WITH INTRAOCULAR LENS IMPLANTATION IN PATIENTS WITH HIGH MYOPIA

    Directory of Open Access Journals (Sweden)

    Sunil

    2015-11-01

    Full Text Available : OBJECTIVE: To evaluate the visual and refractive outcomes of phacoemulsification with intraocular lens (IOL implantation in highly myopic eyes and to assess the intraoperative and postoperative complications. SETTINGS: Tertiary care Centre Ranchi, India. METHODS: Consecutive patients with high myopia were retrospectively studied for outcomes and complications after phacoemulsification and IOL implantation. RESULTS: The study included 125 eyes of 89 patients (53 females and 36 males with a mean age of 56.01±9.51 years and mean follow-up of 19.45±4.07 months. The mean axial length was 29.58±2.57mm and power of the IOL ranged from −4.00 D to + 17.00 D. The mean preoperative logMAR Best corrected visual acuity (BCVA was 0.82±0.26 which improved to 0.38±0.29 at one month and to 0.43±0.33 at last follow-up, the improvement in vision was statistically significant (P<0.0001, paired t test. Postoperatively, 80 eyes (64% had a BCVA between 0.00 logMAR (20/20 and 0.30 logMAR (20/40. Pre-existing myopic chorioretinal degeneration (13.6% was most common factor causing decreased visual acuity. The mean spherical equivalent at one month postoperative was -0.06±1.28 D. The complications included posterior capsule rupture (5.6%, zonular dehiscence (1.6%, retinal detachment (1.6%, cystoid macular edema (8.8% and posterior capsule opacifications (10.4%. CONCLUSIONS: Phacoemulsification with intraocular lens implantation is a safe and effective procedure to improve patients visual acuity in those with high myopia.

  8. Distance between Anterior Commissure and the First Tracheal Ring: An Important New Clinical Laryngotracheal Measurement

    Directory of Open Access Journals (Sweden)

    Ehsan Khadivi

    2015-05-01

    Full Text Available Introduction: The distance between the anterior commissure of the larynx and the first tracheal ring (AC.T. distance is of great importance in laryngotracheal surgeries.  The amount of narrowing of the subglottic airway is used as a quantitative mean to determine whether the lesion is subglottic or has extended to the trachea and therefore helps in the prediction of the final prognosis.   Materials and Methods: In this study, the larynx was exposed by direct laryngoscopy under general anesthesia. The case was considered to be difficult because the exposure did not optimally reveal the anterior commissure, therefore a cricoid tape or anterior commissure laryngoscope was used. A zero degree Hopkins lens was used to view the anterior commissure and the first tracheal ring. Special markers were used to mark the two points with the distance between those being considered as the AC.T. distance. The relationship between AC.T. distance and the patient's age, sex, BMI, and laryngeal exposure condition during laryngoscopy was also studied.   Results: Eighty-two patients participated in this study. The mean AC.T. distance was measured and was found to be 32.67±3.34 mm in males and 29.80± 3.00 mm in females. This difference was statistically significant between the two groups (P

  9. Positioning of anterior teeth in removable dentures

    Directory of Open Access Journals (Sweden)

    Strajnić Ljiljana

    2002-01-01

    Full Text Available Introduction The aim of this paper was to present methods of placement of artificial anterior teeth in edentulous individuals. The following review takes account of the majority of papers published during the last 100 years. The review has been divided into sections regarding the method used to determine the position of artificial anterior teeth. Geometric aspect Gysi (1895-1920 produced the first scientific theory about the position of artificial anterior teeth. Physiognomic theory The aim of this theory is to find the most natural position for artificial anterior teeth for each individual. Camper's "face angle" as a physiognomic criterion, has been introduced in papers of Wehrli (1961, Marxhors (1966, Tanzer (1968, Lombardi (1973. Esthetic aspect Important names in the field of dental esthetics are: Schön and Singer (1961, Arnheim (1965, Krajiček (1969, Tanzer (1968, Lombardi (1973, Goldstein (1976. They have introduced principles of visual aspects for selection of contours, dimension and position of artificial anterior teeth. Constitution aspect Flagg (1880, Williams (1913 and Hrauf (1957, 1958, have considered body constitution and individual characteristics regarding position of artificial anterior teeth. Physiological theory In 1971, Marxhors pointed to the fact that the position of artificial teeth corresponds with the function of the surrounding soft tissue and from the aspect of physiognomy as well. Phonetic aspect According to Silverman (1962 artificial anterior teeth are nearest when we pronounce the sound "S". Cephalometrical research Rayson (1970, Watson (1989, Strajnić Lj. (1999, Bassi F. (2001 have presented cephalometric radiographic analyses of natural anterior teeth compared with cephalometric radiographic analyses of artificial anterior teeth. A review of dental literature shows several factors suggesting modalities which should determine the position of artificial anterior teeth. Numerous methods have been designed for

  10. Pharyngocutaneous fistula after anterior cervical spine surgery

    OpenAIRE

    Sansur, Charles A.; Early, Stephen; Reibel, James; Arlet, Vincent

    2009-01-01

    Pharyngocutaneous fistulae are rare complications of anterior spine surgery occurring in less than 0.1% of all anterior surgery cases. We report a case of a 19 year old female who sustained a C6 burst fracture with complete quadriplegia. She was treated urgently with a C6 corpectomy with anterior cage and plating followed by posterior cervical stabilization at another institution. Post operatively she developed a pharyngocutaneous fistula that failed to heal despite several attempts of closu...

  11. Incidental Anterior Cruciate Ligament Calcification: Case Report.

    Science.gov (United States)

    Hayashi, Hisami; Fischer, Hans

    2016-03-01

    The calcification of knee ligaments is a finding noted only in a handful of case reports. The finding of an anterior cruciate ligament calcification has been reported once in the literature. Comparable studies involving the posterior cruciate ligament, medial collateral ligament and an ossicle within the anterior cruciate ligament are likewise discussed in reports of symptomatic patients. We report a case of incidentally discovered anterior cruciate ligament calcification. We discuss the likely etiology and clinical implications of this finding.

  12. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants

    International Nuclear Information System (INIS)

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  13. Bushen Yisui Capsule ameliorates axonal injury in experimental autoimmune encephalomyelitis

    Institute of Scientific and Technical Information of China (English)

    Ling Fang; Lei Wang; Qi Zheng; Tao Yang; Hui Zhao; Qiuxia Zhang; Kangning Li; Li Zhou; Haiyang Gong; Yongping Fan

    2013-01-01

    A preliminary clinical study by our group demonstrated Bushen Yisui Capsule (formerly cal ed Er-huang Formula) in combination with conventional therapy is an effective prescription for the treat-ment of multiple sclerosis. However, its effect on axonal injury during early multiple sclerosis re-mains unclear. In this study, a MOG 35-55-immunized C57BL/6 mouse model of experimental au-toimmune encephalomyelitis was intragastrical y administered Bushen Yisui Capsule. The results showed that Bushen Yisui Capsule effectively improved clinical symptoms and neurological function of experimental autoimmune encephalomyelitis. In addition, amyloid precursor protein expression was down-regulated and microtubule-associated protein 2 was up-regulated. Experimental findings indicate that the disease-preventive mechanism of Bushen Yisui Capsule in experimental autoim-mune encephalomyelitis was mediated by amelioration of axonal damage and promotion of rege-neration. But the effects of the high-dose Bushen Yisui Capsule group was not better than that of the medium-dose and low-dose Bushen Yisui Capsule group in preventing neurological dysfunction.

  14. Pickering Emulsion-Based Marbles for Cellular Capsules

    Directory of Open Access Journals (Sweden)

    Guangzhao Zhang

    2016-07-01

    Full Text Available The biodegradable cellular capsule, being prepared from simple vaporization of liquid marbles, is an ideal vehicle for the potential application of drug encapsulation and release. This paper reports the fabrication of cellular capsules via facile vaporization of Pickering emulsion marbles in an ambient atmosphere. Stable Pickering emulsion (water in oil was prepared while utilizing dichloromethane (containing poly(l-lactic acid and partially hydrophobic silica particles as oil phase and stabilizing agents respectively. Then, the Pickering emulsion marbles were formed by dropping emulsion into a petri dish containing silica particles with a syringe followed by rolling. The cellular capsules were finally obtained after the complete vaporization of both oil and water phases. The technique of scanning electron microscope (SEM was employed to research the microstructure and surface morphology of the prepared capsules and the results showed the cellular structure as expected. An in vitro drug release test was implemented which showed a sustained release property of the prepared cellular capsules. In addition, the use of biodegradable poly(l-lactic acid and the biocompatible silica particles also made the fabricated cellular capsules of great potential in the application of sustained drug release.

  15. Electromagnetic wave propagation of wireless capsule endoscopy in human body

    Institute of Scientific and Technical Information of China (English)

    LIM; Eng-Gee; 王炤; 陈瑾慧; TILLO; Tammam; MAN; Ka-lok

    2013-01-01

    Wireless capsule endoscopy(WCE) is a promising technique which has overcome some limitations of traditional diagnosing tools, such as the comfortlessness of the cables and the inability of examining small intestine section. However, this technique is still far from mature and asks for the feasible improvements. For example, the relatively low transmission data rate and the absence of the real-time localization information of the capsule are all important issues. The studies of them rely on the understanding of the electromagnetic wave propagation in human body. Investigation of performance of WCE communication system was carried out by studying electromagnetic(EM) wave propagation of the wireless capsule endoscopy transmission channel. Starting with a pair of antennas working in a human body mimic environment, the signal transmissions and attenuations were examined. The relationship between the signal attenuation and the capsule(transmitter) position, and direction was also evaluated. These results provide important information for real-time localization of the capsule. Moreover, the pair of antennas and the human body were treated as a transmission channel, on which the binary amplitude shift keying(BASK) modulation scheme was used. The relationship between the modulation scheme, data rate and bit error rate was also determined in the case of BASK. With the obtained studies, it make possible to provide valuable information for further studies on the selection of the modulation scheme and the real-time localization of the capsules.

  16. Simulating Space Capsule Water Landing with Explicit Finite Element Method

    Science.gov (United States)

    Wang, John T.; Lyle, Karen H.

    2007-01-01

    A study of using an explicit nonlinear dynamic finite element code for simulating the water landing of a space capsule was performed. The finite element model contains Lagrangian shell elements for the space capsule and Eulerian solid elements for the water and air. An Arbitrary Lagrangian Eulerian (ALE) solver and a penalty coupling method were used for predicting the fluid and structure interaction forces. The space capsule was first assumed to be rigid, so the numerical results could be correlated with closed form solutions. The water and air meshes were continuously refined until the solution was converged. The converged maximum deceleration predicted is bounded by the classical von Karman and Wagner solutions and is considered to be an adequate solution. The refined water and air meshes were then used in the models for simulating the water landing of a capsule model that has a flexible bottom. For small pitch angle cases, the maximum deceleration from the flexible capsule model was found to be significantly greater than the maximum deceleration obtained from the corresponding rigid model. For large pitch angle cases, the difference between the maximum deceleration of the flexible model and that of its corresponding rigid model is smaller. Test data of Apollo space capsules with a flexible heat shield qualitatively support the findings presented in this paper.

  17. [Clinical practice using colon capsule endoscopy].

    Science.gov (United States)

    Kakugawa, Yasuo; Matsumoto, Minori; Saito, Yutaka

    2014-01-01

    PillCam COLON capsule endoscopy(CCE) (Given Imaging Ltd., Yoqneam, Israel) is one of the most recent diagnostic technologies designed to explore the colorectum. The first generation of CCE was released onto the market in 2006, and the second generation (PillCam COLON 2 : CCE-2), with increased sensitivity, was released in 2009. The CCE-2 has 2 imagers with a much wider angle of view that has been increased to 172 degrees per imager, allowing nearly 360 degrees coverage of the colon by two. The most unique feature of the CCE-2 is its adaptive frame rate (AFR). This new technology allows the CCE-2 to capture 35 images per second when in motion and 4 images per second when virtually stationary. The per-patient CCE-2 sensitivity for detecting polyps > or = 6 mm has been reported as 84%-91%. These recent advancements in this modality might offer physicians the option to screen for colorectal lesions noninvasively. PMID:24597367

  18. Orion Capsule Handling Qualities for Atmospheric Entry

    Science.gov (United States)

    Tigges, Michael A.; Bihari, Brian D.; Stephens, John-Paul; Vos, Gordon A.; Bilimoria, Karl D.; Mueller, Eric R.; Law, Howard G.; Johnson, Wyatt; Bailey, Randall E.; Jackson, Bruce

    2011-01-01

    Two piloted simulations were conducted at NASA's Johnson Space Center using the Cooper-Harper scale to study the handling qualities of the Orion Command Module capsule during atmospheric entry flight. The simulations were conducted using high fidelity 6-DOF simulators for Lunar Return Skip Entry and International Space Station Return Direct Entry flight using bank angle steering commands generated by either the Primary (PredGuid) or Backup (PLM) guidance algorithms. For both evaluations, manual control of bank angle began after descending through Entry Interface into the atmosphere until drogue chutes deployment. Pilots were able to use defined bank management and reversal criteria to accurately track the bank angle commands, and stay within flight performance metrics of landing accuracy, g-loads, and propellant consumption, suggesting that the pilotability of Orion under manual control is both achievable and provides adequate trajectory performance with acceptable levels of pilot effort. Another significant result of these analyses is the applicability of flying a complex entry task under high speed entry flight conditions relevant to the next generation Multi Purpose Crew Vehicle return from Mars and Near Earth Objects.

  19. [Anticonvulsant and psychotropic effects of topamax capsules].

    Science.gov (United States)

    Kalinin, V V; Zheleznova, E V; Sokolova, L V; Zemlianaia, A A

    2009-01-01

    Anticonvulsant and psychotropic effects of "Topamax capsules"(TC) were compared to a traditional form of topiramate (TFT) and some other anticonvulsant drugs (ACD). Thirty-six patients (12 men and 24 women) with partial temporary epilepsy were examined. Sixteen patients received TFT in tablets and 20 patients received ACD before the beginning of the study. Drug effect was assessed by frequency of seizures and some neuropsychiatric parameters. The results revealed that TC was comparable to TFT and ACD in the reduction of seizures of any semiotics. After 3 months of therapy, total MMSE scores increased from 27 to 28. There were less perseverant errors and more right responses in the WCST. Verbal fluency and memory measured with Sunderland test improved as well. TC led to decreased latencies of negative responses in the WCST and increased verbal fluency compared to TFT. Patients who received TFT prior to TC did fewer errors in the WCST than patients who received ACD prior to TC. Verbal fluency improved compared to patients who received other ACD. At the same time, a somewhat increase of paranoid signs on the scale SCL-90 was noted in the group treated with topiramate only. It has been concluded that TC has an activating effect on frontal brain areas.

  20. Intraocular lens alignment from an en face optical coherence tomography image Purkinje-like method

    Science.gov (United States)

    Sun, Mengchan; de Castro, Alberto; Ortiz, Sergio; Perez-Merino, Pablo; Birkenfeld, Judith; Marcos, Susana

    2014-06-01

    Measurement of intraocular lens (IOL) alignment implanted in patients in cataract surgery is important to understand their optical performance. We present a method to estimate tilt and decentration of IOLs based on optical coherence tomography (OCT) images. En face OCT images show Purkinje-like images that correspond to the specular reflections from the corneal and IOL surfaces. Unlike in standard Purkinje-imaging, the tomographic nature of OCT allows unequivocal association of the reflection with the corresponding surface. The locations of the Purkinje-like images are linear combinations of IOL tilt, IOL decentration, and eye rotation. The weighting coefficients depend on the individual anterior segment geometry, obtained from the same OCT datasets. The methodology was demonstrated on an artificial model eye with set amounts of lens tilt and decentration and five pseudophakic eyes. Measured tilt and decentration in the artificial eye differed by 3.7% and 0.9%, respectively, from nominal values. In patients, average IOL tilt and decentration from Purkinje were 3.30±4.68 deg and 0.16±0.16 mm, respectively, and differed on average by 0.5 deg and 0.09 mm, respectively, from direct measurements on distortion-corrected OCT images. Purkinje-based methodology from anterior segment en face OCT imaging provided, therefore, reliable measurements of IOL tilt and decentration.

  1. Imaging of aphakic intraocular lens with a slit-scanning tomography system

    Science.gov (United States)

    Oliveira, Cristina M.; Almeida, J. B.; Franco, S.

    2011-05-01

    Nowadays, cataract extraction with IOL implantation aims not only to restore the crystalline lens' transparency, but also to improve patients' retinal image quality. The refractive outcome and visual quality in pseudophakic eyes is mainly determined by the combination of corneal and internal optics resulting from the implanted IOLs. The optical function of the IOLs depends on its position in the eye. The IOL distance to the corneal apex determines the optical power needed for optical correction. In this paper it is described the usage of a slit-scanning imaging system to determine IOL positioning. Through the projection of the light from a slit onto the eye, this tomography system allows to acquire multiple sections of the anterior eye segment, at different meridians. The developed system's software corrects geometric and optical distortion of the images and provides 3-dimentional models of the eye's structures from the 2-dimensional sections. With this noninvasive technique, cross-sectional images of an eye with an aphakic IOL were obtained in order to reconstruct its 3- dimensional model of the lens and assess its position in the anterior segment camera.

  2. Perawatan Gigitan Terbalik Anterior Dengan Menggunakan Inclined Plane

    OpenAIRE

    Siregar, Wilda A.

    2008-01-01

    Gigitan terbalik anterior adalah suatu anomali posisi gigi anterior atas yang lebih ke lingual dibandingkan gigi anterior bawah. Anomali gigitan terbalik anterior dapat ditemui pada periode gigi sulung, gigi bercampur, dan gigi permanen. Faktor etiologi gigitan terbalik anterior dibedakan atas dental, fungsional atau skeletal. Untuk menentukan etiologi dari anomali gigitan terbalik anterior perlu dilakukan diagnosa yang tepat. Perawatan gigitan terbalik anterior ini dapat dilakukan de...

  3. Gravitational binary-lens events with prominent effects of lens orbital motion

    Energy Technology Data Exchange (ETDEWEB)

    Park, H.; Han, C.; Choi, J.-Y. [Department of Physics, Institute for Astrophysics, Chungbuk National University, Cheongju 371-763 (Korea, Republic of); Udalski, A.; Szymański, M. K.; Kubiak, M.; Soszyński, I.; Pietrzyński, G.; Poleski, R.; Ulaczyk, K.; Pietrukowicz, P.; Kozłowski, S.; Skowron, J.; Wyrzykowski, Ł. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Gould, A.; Gaudi, B. S. [Department of Astronomy, The Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Beaulieu, J.-P. [Institut d' Astrophysique de Paris, UMR 7095 CNRS-Université Pierre and Marie Curie, 98bis Bd Arago, F-75014 Paris (France); Tsapras, Y. [Las Cumbres Observatory Global Telescope Network, 6740 Cortona Drive, Suite 102, Goleta, CA 93117 (United States); Depoy, D. L. [Department of Physics and Astronomy, Texas A and M University, College Station, TX 77843 (United States); Dong, Subo [Institute for Advanced Study, Einstein Drive, Princeton, NJ 08540 (United States); Collaboration: OGLE Collaboration; μFUN Collaboration; PLANET Collaboration; RoboNet Collaboration; and others

    2013-12-01

    Gravitational microlensing events produced by lenses composed of binary masses are important because they provide a major channel for determining physical parameters of lenses. In this work, we analyze the light curves of two binary-lens events, OGLE-2006-BLG-277 and OGLE-2012-BLG-0031, for which the light curves exhibit strong deviations from standard models. From modeling considering various second-order effects, we find that the deviations are mostly explained by the effect of the lens orbital motion. We also find that lens parallax effects can mimic orbital effects to some extent. This implies that modeling light curves of binary-lens events not considering orbital effects can result in lens parallaxes that are substantially different from actual values and thus wrong determinations of physical lens parameters. This demonstrates the importance of routine consideration of orbital effects in interpreting light curves of binary-lens events. It is found that the lens of OGLE-2006-BLG-277 is a binary composed of a low-mass star and a brown dwarf companion.

  4. The Sloan Lens ACS Survey. V. The full ACS strong-lens sample

    NARCIS (Netherlands)

    Bolton, Adam S.; Burles, Scott; Koopmans, Leon V. E.; Treu, Tommaso; Gavazzi, Raphael; Moustakas, Leonidas A.; Wayth, Randall; Schlegel, David J.

    2008-01-01

    We present the definitive data for the full sample of 131 strong gravitational lens candidates observed with the Advanced Camera for Surveys (ACS) aboard the Hubble Space Telescope by the Sloan Lens ACS (SLACS) Survey. All targets were selected for higher redshift emission lines and lower redshift c

  5. Effect of infusion bottle height on lens power after lens refilling with and without a plug

    NARCIS (Netherlands)

    Koopmans, SA; Terwee, T; Haitjema, HJ; Kooijman, AC; Barkhof, J

    2003-01-01

    Purpose: To evaluate the influence of intraoperative infusion bottle height on the power of refilled pig lenses. Setting: Research Laboratory, Pharmacia Intraocular Lens Manufacturing Plant, Groningen, The Netherlands. Methods: This study comprised 2 groups of pig eyes. In 1 group, the lens was refi

  6. Optical integration of Pancharatnam-Berry phase lens and dynamical phase lens

    Science.gov (United States)

    Ke, Yougang; Liu, Yachao; Zhou, Junxiao; Liu, Yuanyuan; Luo, Hailu; Wen, Shuangchun

    2016-03-01

    In the optical system, most elements such as lens, prism, and optical fiber are made of silica glass. Therefore, integrating Pancharatnam-Berry phase elements into silica glass has potential applications in the optical system. In this paper, we take a lens, for example, which integrates a Pancharatnam-Berry phase lens into a conventional plano-convex lens. The spin states and positions of focal points can be modulated by controlling the polarization states of the incident beam. The proposed lens has a high transmission efficiency, and thereby acts as a simple and powerful tool to manipulate spin photons. Furthermore, the method can be conveniently extended to the optical fiber and laser cavity, and may provide a route to the design of the spin-photonic devices.

  7. Early clinical outcome with a new monofocal microincision intraocular lens.

    Science.gov (United States)

    Toygar, Baha; Yabas Kiziloglu, Ozge; Toygar, Okan; Hacimustafaoglu, Ali Murat

    2016-10-01

    The purpose of this study was to evaluate the early visual and refractive outcomes of a new aspheric monofocal microincision intraocular lens (IOL). This retrospective case series included eyes of patients who underwent implantation of a microincision IOL following 1.8 mm manual coaxial microincision cataract surgery and who attended regular postoperative follow-up visits on the first week and first, third, and sixth months. The postoperative uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), refraction and predictability, intraoperative and postoperative complications, posterior capsule opacification (PCO), IOL centration, and surgically induced astigmatism (SIA) were evaluated. Sixty-three eyes of 38 patients ranging in age from 51 to 86 were included in the study. The mean preoperative BCVA was 0.52 ± 0.42 logMAR. At the postoperative sixth month, the mean postoperative UCVA and BCVA were 0.12 ± 0.11 and 0.01 ± 0.03 logMAR, respectively. The mean postoperative spherical equivalent refraction (SER) was -0.30 ± 0.49 D. The SER was within ± 1.00 D of the attempted correction in 95.2 % of the eyes. The mean SIA measured with vector analysis was 0.45 ± 0.28 D. Mild PCO was observed in 9 eyes (14.7 %) with none requiring Nd:Yag laser capsulotomy. On centration analysis, the IOL was found to be 0.26 mm on average to the supero-nasal position. The aspheric microincision IOL was safely implanted and provided satisfactory visual and refractive outcomes in the early postoperative period.

  8. Pseudophakic hyperopia in nanophthalmic eyes managed by a posterior chamber implantable collamer lens

    Directory of Open Access Journals (Sweden)

    Kothari Kulin

    2011-01-01

    Full Text Available We report a case of a bilateral posterior chamber implantable collamer lens (ICL implantation post-clear lens extraction, to reduce the residual hyperopia, in a patient with nanophthalmic eyes. A 30-year-old female patient, keen to reduce her dependency on glasses and contact lenses, came to our refractive surgery department. Her refractive error was +12.0 and +12.5 diopters in the right and left eye, respectively, with steep corneas on keratometry and a shallow anterior chamber depth. She underwent clear lens extraction with implantation of +35.0 D and +40.0 D IOL in the right eye and left eye, respectively. Her post-operative best-corrected visual acuity was 20/30 with +8.5 D in the right eye and +6 D in the left. She underwent bilateral ICL implantation. Postoperatively after 6 months, her unaided visual acuity was 20/30 in both eyes. In conclusion, ICL implantation can be considered to correct residual hypermetropic ametropia in pseudophakic eyes when other options have limitations.

  9. A retrospective analysis of the first Indian experience on Artisan phakic intraocular lens

    Directory of Open Access Journals (Sweden)

    Senthil Sirisha

    2006-01-01

    Full Text Available Purpose: To evaluate the efficacy, safety, predictability and stability of implanting a polymethylmethacrylate phakic intraocular lens (PIOL in high myopia. Materials and Methods: A retrospective analysis of the data of patients who underwent Artisan phakic IOL implantation between 2002 and 2003 with a follow-up of at least 24 months. Results: An Artisan myopia lens was implanted in 60 eyes of 36 patients with preoperative myopia ranging from -5.0 to -24.0 D. Mean patient age was 22.6 years. Mean spherical equivalent of manifest refraction stabilized by the first postoperative week. At three months follow-up, 54 eyes (90% had a postoperative refraction within ± 1D emmetropia and 45 eyes (75% had uncorrected visual acuity of 20/40 or better. Seven eyes (11.6% had loss of one Snellen line and none had loss of two Snellen lines or more at three months. The mean endothelial cell loss was 3.8% at three months, 5.2% at six months, 5.25% at 12 months and 6.38% at two years, which was not significant. Postoperative complications included anterior chamber reaction in two eyes (3.3%, rise in intraocular pressure in six eyes (10% and dislocation of PIOL in two eyes (3.3%. Conclusion: Implantation of Artisan myopia lens to correct high myopia resulted in a stable and fairly predictable refractive outcome with few complications. Significant endothelial damage was not detected in two years of follow-up.

  10. Toxic Anterior Segment Syndrome (TASS

    Directory of Open Access Journals (Sweden)

    Özlem Öner

    2011-12-01

    Full Text Available Toxic anterior segment syndrome (TASS is a sterile intraocular inflammation caused by noninfectious substances, resulting in extensive toxic damage to the intraocular tissues. Possible etiologic factors of TASS include surgical trauma, bacterial endotoxin, intraocular solutions with inappropriate pH and osmolality, preservatives, denatured ophthalmic viscosurgical devices (OVD, inadequate sterilization, cleaning and rinsing of surgical devices, intraocular lenses, polishing and sterilizing compounds which are related to intraocular lenses. The characteristic signs and symptoms such as blurred vision, corneal edema, hypopyon and nonreactive pupil usually occur 24 hours after the cataract surgery. The differential diagnosis of TASS from infectious endophthalmitis is important. The main treatment for TASS formation is prevention. TASS is a cataract surgery complication that is more commonly seen nowadays. In this article, the possible underlying causes as well as treatment and prevention methods of TASS are summarized. (Turk J Oph thal mol 2011; 41: 407-13

  11. Mild toxic anterior segment syndrome mimicking delayed onset toxic anterior segment syndrome after cataract surgery

    Directory of Open Access Journals (Sweden)

    Su-Na Lee

    2014-01-01

    Full Text Available Toxic anterior segment syndrome (TASS is an acute sterile postoperative anterior segment inflammation that may occur after anterior segment surgery. I report herein a case that developed mild TASS in one eye after bilateral uneventful cataract surgery, which was masked during early postoperative period under steroid eye drop and mimicking delayed onset TASS after switching to weaker steroid eye drop.

  12. Reverse Optic Capture to Stabilize a Toric Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Howard V. Gimbel

    2013-09-01

    Full Text Available Purpose: To describe a technique for stabilizing a rotationally unstable toric intraocular lens (IOL. Method: Case report and literature review. Results: Surgical technique and long-term follow-up for a patient who underwent repositioning and stabilization of a mobile 1-piece acrylic toric IOL using reverse optic capture (ROC are described. This patient presented with early, more than 70° off-axis rotation. The IOL was repositioned but was very mobile within the bag and tended to rotate off-axis; hence, it was stabilized in the desired position by capturing the optic through the anterior continuous curvilinear capsulorhexis, leaving the haptics in the bag. The immediate and 2-year postoperative follow-up revealed a stable and on-axis IOL with no visual, refractive or ocular complications. Conclusions: ROC is a useful and safe technique to address the problem of toric IOLs that tend to rotate at the time of surgery or are not stable postoperatively.

  13. New Management of Angle-closure Glaucoma by Phacoemulsification with Foldable Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Jian Ge; Yan Guo; Yizhi Liu; Mingkai Lin; Yehong Zhuo; Bing Chen; Xiuqi Chen

    2000-01-01

    Objective: To investigate the management of angle-closure glaucoma by phacoemulsification with foldable posterior chamber intraocular lens (PC-IOL) implantation. Design: Retrospective, noncontrolled interventional case series.Participants: In 36 eyes with angle-closure glaucoma (ACG), there were 18 eyes with primary acute angle-closure glaucoma (PACG), 14 eyes with primary chronic angle-closure glaucoma (PCCG), 3 eyes with secondary acute angle-closure glaucoma (SACG) and 1 eye with secondary chronic angle-closure glaucoma (SCCG).Intervention: Phacoemulsification with posterior chamber intraocular lens implantation.Main Outcome Measures: Postoperative visual acuity, IOP, axial anterior chamber depth.Results: After a mean postoperative follow-up time of 8.81 ± 7.45 months, intraocular pressure was reduced from a preoperative mean of 23.81 ± 17.84 mmHg to a postoperative mean of 12.54 ± 4. 73 mmHg ( P = 0. 001 ). Mean anterior chamber depth was 1.75 ± 0.48 mm preoperatively and 2.29 ± 0.38 mm postoperatively ( P = 0. 000).Best spectacle-corrected visual acuity in 36 eyes ranged from 0. 01 to 0. 7 (20/200 to 20/30) postoperatively, which was better than preoperative VA ranging from hand movement to 0.4 (20/50) ( P= 0. 000).Conclusion: Phacoemulsification with posterior chamber foldable intraocular lens implantation can be a good alternative in treating angle-closure glaucoma. Eye Science 2000; 16:22 ~ 28.

  14. New Management of Angle-closure Glaucoma by Phacoemulsification with Folable Posterior Chamber Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    JianGE; YanGuo; 等

    2002-01-01

    Objective:To investigate the management of angle-closure glaucoma by phacoemulsification with foldable posterior chamber intraocular lens (PC-IOIL)implantation.Design:Retrospective,noncontrolled interventional case series.Participants:In 36 eyes with angle -closure glaucoma(ACG).there were 18eyes with primary acute angle-closure glaucoma(PACG),14 eyes with primary chonic angle -closure glaucoma(PCCG),3 eyes with secondary acute angle-closure glaucoma (SACG) and 1 eye with secondary chronic angle -closure glaucoma(SCCG).Intervention:Phacoemulsification with posterior chamber intraocular lens implantation.Main Outcome Measures:Postoperative visual acuity,IOP,axial anterior chamber depth.Results:After a mean postoperative follow -time of 8.81±7.45 months,intraocular pressure was reduced from a preoperative mean of 23.81±17.84 mmHg to a postoperative mean of 12.54±4.73mmHg(P=0.001).Mean anterior chamber depth was 1.75±0.48 mm preoiperatively and 2.29±0.38mm postoperatively(P-0.000).Best spectacle-corrected visual acuity in 36 eyes ranged from 0.01 to 0.7(20/200 to 20/30)postoperatively,which was better than preoperative VA ranging from hand movement to 0.4(20/50)(P=0.000).Conclusion:Phacoemulsification with posterior chamber foldable intraocular lens implantation can be a good alternative in treating angle-closure glaucoma.Eye Science2000;16:22-28.

  15. [Representation and mathematical analysis of human crystalline lens].

    Science.gov (United States)

    Tălu, Stefan; Giovanzana, Stefano; Tălu, Mihai

    2011-01-01

    The surface of human crystalline lens can be described and analyzed using mathematical models based on parametric representations, used in biomechanical studies and 3D solid modeling of the lens. The mathematical models used in lens biomechanics allow the study and the behavior of crystalline lens on variables and complex dynamic loads. Also, the lens biomechanics has the potential to improve the results in the development of intraocular lenses and cataract surgery. The paper presents the most representative mathematical models currently used for the modeling of human crystalline lens, both optically and biomechanically.

  16. Imaging the anterior eye with dynamic-focus swept-source optical coherence tomography

    Science.gov (United States)

    Su, Johnny P.; Li, Yan; Tang, Maolong; Liu, Liang; Pechauer, Alex D.; Huang, David; Liu, Gangjun

    2015-12-01

    A custom-built dynamic-focus swept-source optical coherence tomography (SS-OCT) system with a central wavelength of 1310 nm was used to image the anterior eye from the cornea to the lens. An electrically tunable lens was utilized to dynamically control the positions of focusing planes over the imaging range of 10 mm. The B-scan images were acquired consecutively at the same position but with different focus settings. The B-scan images were then registered and averaged after filtering the out-of-focus regions using a Gaussian window. By fusing images obtained at different depth focus locations, high-resolution and high signal-strength images were obtained over the entire imaging depth. In vivo imaging of human anterior segment was demonstrated. The performance of the system was compared with two commercial OCT systems. The human eye ciliary body was better visualized with the dynamic-focusing SS-OCT system than using the commercial 840 and 1310 nm OCT systems. The sulcus-to-sulcus distance was measured, and the result agreed with that acquired with ultrasound biomicroscopy.

  17. Ultraviolet absorption by contact lenses and the significance on the ocular anterior segment.

    Science.gov (United States)

    Chandler, Heather

    2011-07-01

    It is well established that both acute and chronic ultraviolet (UV) exposure can lead to various ophthalmic pathologic conditions in the anterior segment. Several scientific studies have demonstrated that after UV exposure, the unprotected cornea is vulnerable to damage in the epithelial, stromal, and endothelial cellular layers. DNA damage, apoptosis, and altered protease expression are all examples of harmful changes that can occur within the cornea after irradiation. Beyond the cornea, damage associated with UV exposure, such as decreased antioxidant levels and increased reactive oxygen species production, has been noted in the aqueous humor and crystalline lens. Ultraviolet-blocking contact lenses have the potential to provide protection against such exposure to harmful UV radiation. Experimental use of UV-absorbing contact lenses prevented detrimental cellular changes to the cornea and maintained corneal clarity after UV exposure. Additionally, studies suggest that shielding the aqueous humor and crystalline lens from irradiation with UV-absorbing contact lenses aids in protection against precataractous changes. Despite ongoing research, to date, neither chronic nor clinical studies have been performed in humans to demonstrate that wearing UV-blocking contact lenses reduces the risk of developing cataracts or other ocular disorders within the anterior segment. This article will discuss the impact of UV exposure on ocular tissue and the need for adequate UV protection, with particular emphasis on UV-blocking contact lenses.

  18. Evaluation of Anterior Chamber Volume in Cataract Patients with Swept-Source Optical Coherence Tomography.

    Science.gov (United States)

    He, Wenwen; Zhu, Xiangjia; Wolff, Don; Zhao, Zhennan; Sun, Xinghuai; Lu, Yi

    2016-01-01

    Purpose. To evaluate the anterior chamber volume in cataract patients with Swept-Source Optical Coherence Tomography (SS-OCT) and its influencing factors. Methods. Anterior chamber volume of 92 cataract patients was evaluated with SS-OCT in this cross-sectional study. Univariate analyses and multiple linear regression were used to investigate gender, age, operated eye, posterior vitreous detachment, lens opacity grading, and axial length (AXL) related variables capable of influencing the ACV. Results. The average ACV was 139.80 ± 38.21 mm(3) (range 59.41 to 254.09 mm(3)). The average ACV was significantly larger in male patients than in female patients (P = 0.001). ACV was negatively correlated with age and LOCS III cortical (C) grading of the lens (Pearson's correlation analysis, r = -0.443, P ACV was also increased with AXL (Pearson's correlation analysis, r = 0.552, P ACV (F = 10.252  P ACV varied significantly among different subjects. Influencing factors that contribute to reduced ACV were female gender, increased age, LOCS III C grade, and shorter AXL.

  19. Design and fabrication of soft zoom lens

    Science.gov (United States)

    Lin, Wei-Cheng; Chen, Chao-Chang A.; Huang, Kuo-Cheng

    2008-08-01

    With minimization of optical-electronics devices, conventional optical zoom lens component has been explored with liquid lens and soft polymer membranes. This paper introduces a novel zoom lens system with a soft polymer material, Polydimethylsiloxane (PDMS), its shape and curvature can be controlled by pneumatic pressure. Therefore, effective focal length (EFL) of soft zoom lens (SZL) system can be controlled and altered. According to desired opto-mechanical design, this ZL has been accessed to determine the optical specifications. After the pressure activated from 0 to 0.02MPa, the change of EFL of the SZL system can reach up to 18.77% (33.44mm to 39.717mm). Experimental results show that zoom effects of the developed SZL system are significantly affected by the shape, thickness and curing parameter of PDMS soft lens. The SZL system has been verified with the function of zoom ability. Further research works on the integration of the SZL system with imaging system for mobile devices or robot vision applications.

  20. Models of the Cosmic Horseshoe Gravitational Lens

    CERN Document Server

    Dye, Simon; Belokurov, V; Warren, S J; Hewett, P

    2008-01-01

    We model the extremely massive and luminous lens galaxy in the Cosmic Horseshoe Einstein ring system, recently discovered in the Sloan Digital Sky Survey. We use the semi-linear method of Warren & Dye (2003), which pixelises the source surface brightness distribution, to invert the Einstein ring for sets of parameterised lens models. Here, the method is refined by exploiting Bayesian inference to optimise adaptive pixelisation of the source plane and to choose between three differently parameterised models: a singular isothermal ellipsoid, a power law model and a NFW profile. The most probable lens model is the power law with a volume mass density that scales as r^(-1.96+/-0.02) and an axis ratio of ~0.8. The mass within the Einstein ring (i.e., within a cylinder with projected distance of ~30 kpc from the centre of the lens galaxy) is (5.02+/-0.09)*10^12 M_solar, and the mass-to-light ratio is ~30. Even though the lens lies in a group of galaxies, the preferred value of the external shear is almost zero....

  1. Clinical Observation of 126 Cases of Sutureless Phacoemulsification with PMMA Intraocular Lens Implantation

    Institute of Scientific and Technical Information of China (English)

    Yanshuang Yan; Zhengxing Mao

    2000-01-01

    Objective: To observe the safety and effect of sutureless phacoemulsification with PMMA intraocular lens (IOL) implantation.Methods: One-hundred and twenty-six cases (126 eyes) of sutureless phacoemulsification with PMMA intraocular lens (IOL) implantation were retrospected and evaluated. The surgeries were performed through a limbal tunnel incision. PMMA IOLs with 5.5mm or 6.0mm in diameter were implanted.Results: The follow-up was 3~20 months. Visual acuity of 0. 5 or better was obtained in 120 cases (95.2%), and that of 1.0 or better was obtained in 89 cases (70. 6% ).Intra-operative complications included posterior capsule rupture in 9 cases (7. 1% ) and iris injury in 7 cases(5.6% ). Postoperative complications included early corneal edema in 96 cases(76.2% ), transient intraocular pressure elevation in 5 cases(4. 3%),remnant of cortex in 1 case and leakage of incision in 1 case. M1 were properly managed with good results.Conclusion: Sutureless phacoemulsification with PMMA IOL implantation is safe even in grass-root hospitals where cataracts are harder.

  2. Completion rates of anterior and posterior continuous curvilinear capsulorrhexis in pediatric cataract surgery for surgery performed by trainee surgeons with the use of a low-cost viscoelastic

    Directory of Open Access Journals (Sweden)

    R Muralidhar

    2012-01-01

    Full Text Available Context : Pediatric cataract surgery is traditionally done with the aid of high-molecular-weight viscoelastics which are expensive. It needs to be determined if low-cost substitutes are just as successful. Aims : The study aims to determine the success rates for anterior and posterior capsulorrhexis and intraocular lens (IOL implantation in the bag for pediatric cataract surgery performed with the aid of a low-molecular-weight viscoelastic. Settings and Design : Nonrandomized observational study. Materials and Methods: Children less than 6 years of age who underwent cataract surgery with IOL implantation in the period May 2008-May 2009 were included. The surgeries were done by pediatric ophthalmology fellows. A standard procedure of anterior capsulorrhexis, lens aspiration with primary posterior capsulorrhexis, anterior vitrectomy, and IOL implantation was followed. Three parameters were studied: successful completion of anterior and posterior capsulorrhexis and IOL implantation in the bag. Results: 33 eyes of 28 children were studied. The success rate for completion was 66.7% and 88.2 % for anterior and posterior capsulorrhexis, respectively. IOL implantation in the bag was successful in 87.9%. Conclusions: 2% hydroxypropylmethylcellulose is a viable low-cost alternative to more expensive options similar to high-molecular-weight viscoelastics. This is of great relevance to hospitals in developing countries.

  3. Anterior segment complications of retinal photocoagulation.

    Science.gov (United States)

    Kanski, J J

    1975-03-01

    Seven patients had anterior segment complications following xenon arc retinal photocoagulation. Irreversible keratopathy was induced in two cases; all patients showed evidence of iris injury. The absorption of radiation by the iris was considered the main factor in producing overheating of the anterior segment.

  4. Dentulous Appliance for Upper Anterior Edentulous Span

    OpenAIRE

    Chalakkal, Paul; Devi, Ramisetty Sabitha; Srinivas, G Vijay; Venkataramana, Pammi

    2013-01-01

    This article discusses about a fixed dentulous appliance that was constructed to replace the primary upper anterior edentulous span in a four year old girl. It constituted a design, whereby the maxillary primary second molars were used to support the appliance through bands and a wire that contained an acrylic flange bearing trimmed acrylic teeth, anteriorly. The appliance was functionally and aesthetically compliant.

  5. Totally thrombosed giant anterior communicating artery aneurysm

    Directory of Open Access Journals (Sweden)

    V R Roopesh Kumar

    2015-01-01

    Full Text Available Giant anterior communicating artery aneurysmsarerare. Apatient presented with visual dysfunction, gait ataxia and urinary incontinence. MRI showed a giant suprasellar mass.At surgery, the lesion was identified as being an aneurysm arising from the anterior communicating artery.The difficulty in preoperative diagnosis and relevant literature are reviewed.

  6. Analytical Quality check of oil based blend in Flaxilip capsule

    Directory of Open Access Journals (Sweden)

    Rajashree Rane

    2014-12-01

    Full Text Available Analysis of capsules containing blend in the powder form is easy, but it is bit difficult to analyse the soft gelatin capsule containing oil based blend. The purpose of this study was to develop test parameters to determine and supervise the quality of such herbal capsule formulation. Five different lots of soft gelatin Flaxilip capsule containing Linseed oil, Guggulu processed with linseed oil, Garlic oil, Fenugreek oil along with Soyabean oil as an excipient , were selected for the study. All the five lots were subjected to general capsule tests such as determination of average weight and disintegration time. Results obtained were around 1.3500g and 10minutes respectively. Specific test parameters applicable for oils like specific gravity, refractive index, acid value, peroxide value, saponification value, iodine value were applied quantitatively for quality evaluation. Standardised suitable classical methods were applied. Results in all the five lots were found to be well within inhouse limit. All the samples were subjected to heavy metals and microbiological testing. Compliance of corresponding findings with the standard pharmacopoeial guidelines assure the safe intake of the drug. For getting the better effect, the Guggulu that is Commiphora mukul used in the formulation was processed with linseed oil. Its presence was confirmed by carrying out HPTLC for E and Z guggulu sterone. Resemblance of spots at Rf ranging from 0.36 to 0.38 and 0.43 to 0.45 in Toluene : Acetone (9:1 system showed the presence of gugulu in blends of all the lots. Hence by applying all these test parameters one can ensure the quality of the soft gelatin ayurvedic capsule formulation containing oily base like in Flaxilip capsule.

  7. Intraocular Lens Opacification following Intracameral Injection of Recombinant Tissue Plasminogen Activator to Treat Inflammatory Membranes after Cataract Surgery

    Directory of Open Access Journals (Sweden)

    Simon S. M. Fung

    2015-01-01

    Full Text Available Purpose. To report 7 cases of intraocular lens (IOL opacification following treatment of postoperative anterior chamber fibrin with recombinant tissue plasminogen activator (rtPA after cataract surgery. Methods. Retrospective case series of 7 eyes in 7 patients who developed IOL opacification after receiving rtPA for anterior chamber inflammatory membrane formation resulting from phacoemulsification cataract surgery. Three explanted IOLs were investigated with light microscopy, histochemical analysis, scanning electron microscopy, and X-ray spectrometry. Results. All patients underwent uncomplicated cataract surgery and posterior chamber hydrophilic IOL implantation. Anterior chamber inflammatory membranes developed between 1 and 4 weeks of surgery and were treated with intracameral rtPA. IOL opacification was noted between 4 weeks and 6 years after rtPA treatment with reduced visual acuity, and IOL exchange was carried out in 3 patients. Light microscopy evaluation revealed diffuse fine granular deposits on the anterior surface/subsurface of IOL optic that stained positive for calcium salts. Scanning electron microscopy (SEM and energy-dispersive X-ray spectrometry (EDS confirmed the presence of calcium and phosphate on the IOL. Conclusions. Intracameral rtPA, though rapidly effective in the treatment of anterior chamber inflammatory membranes following cataract surgery, may be associated with IOL opacification.

  8. Aphakia correction with retropupillary fixated iris-claw lens (Artisan – long-term results

    Directory of Open Access Journals (Sweden)

    Schallenberg M

    2013-12-01

    macular edema were not observed.Conclusion: The presented long-term results demonstrate that retropupillary iris-claw lens implantation is a safe and effective method for the correction of aphakia in patients without capsule support. This surgical procedure has the advantages of a posterior chamber implantation with a low intraoperative and postoperative risk profile.Keywords: aphakia, iris-claw lens, Artisan IOL, retropupillary fixated IOL

  9. Efficient flat metasurface lens for terahertz imaging.

    Science.gov (United States)

    Yang, Quanlong; Gu, Jianqiang; Wang, Dongyang; Zhang, Xueqian; Tian, Zhen; Ouyang, Chunmei; Singh, Ranjan; Han, Jiaguang; Zhang, Weili

    2014-10-20

    Metamaterials offer exciting opportunities that enable precise control of amplitude, polarization and phase of the light beam at a subwavelength scale. A gradient metasurface consists of a class of anisotropic subwavelength metamaterial resonators that offer abrupt amplitude and phase changes, thus enabling new applications in optical device design such as ultrathin flat lenses. We propose a highly efficient gradient metasurface lens based on a metal-dielectric-metal structure that operates in the terahertz regime. The proposed structure consists of slotted metallic resonator arrays on two sides of a thin dielectric spacer. By varying the geometrical parameters, the metasurface lens efficiently manipulates the spatial distribution of the terahertz field and focuses the beam to a spot size on the order of a wavelength. The proposed flat metasurface lens design is polarization insensitive and works efficiently even at wide angles of incidence. PMID:25401626

  10. The Frontier Fields Lens Modeling Comparison Project

    CERN Document Server

    Meneghetti, M; Coe, D; Contini, E; De Lucia, G; Giocoli, C; Acebron, A; Borgani, S; Bradac, M; Diego, J M; Hoag, A; Ishigaki, M; Johnson, T L; Jullo, E; Kawamata, R; Lam, D; Limousin, M; Liesenborgs, J; Oguri, M; Sebesta, K; Sharon, K; Williams, L L R; Zitrin, A

    2016-01-01

    Gravitational lensing by clusters of galaxies offers a powerful probe of their structure and mass distribution. Deriving a lens magnification map for a galaxy cluster is a classic inversion problem and many methods have been developed over the past two decades to solve it. Several research groups have developed techniques independently to map the predominantly dark matter distribution in cluster lenses. While these methods have all provided remarkably high precision mass maps, particularly with exquisite imaging data from the Hubble Space Telescope (HST), the reconstructions themselves have never been directly compared. In this paper, we report the results of comparing various independent lens modeling techniques employed by individual research groups in the community. Here we present for the first time a detailed and robust comparison of methodologies for fidelity, accuracy and precision. For this collaborative exercise, the lens modeling community was provided simulated cluster images -- of two clusters Are...

  11. An inverse and analytic lens design method

    CERN Document Server

    Lu, Yang

    2016-01-01

    Traditional lens design is a numerical and forward process based on ray tracing and aberration theory. This method has limitations because the initial configuration of the lens has to be specified and the aberrations of the lenses have to considered. This paper is an initial attempt to investigate an analytic and inverse lens design method, called Lagrange, to overcome these barriers. Lagrange method tries to build differential equations in terms of the system parameters and the system input and output (object and image). The generalized Snell's law in three dimensional space and the normal of a surface in fundamental differential geometry are applied. Based on the Lagrange method equations for a single surface system are derived which can perfectly image a point object.

  12. Laser light scattering in eye lens model

    Science.gov (United States)

    Larionova, Nadezhda L.; Maksimova, Irina L.; Kochubey, Vyacheslav I.

    2000-11-01

    Theoretical investigations of laser light radiation scattered by eye lens model as a system of spheres with various parameters were performed on the base of Mie theory of electromagnetic scattering by a single sphere. The calculations were performed for systems of particles whose coordinates were specifically realized in random fashion according to the specified probabilities defined by the approximation of hard spheres. The modeling of lens biotissue was carried out by using of medical data about internal structure of lens of human and some animals. In general the researchable model presents the system of homogeneous spherical particles those are randomly distributed in the layer of thickness. We study the optical properties such as scattering effective cross-section and function of correlation in different models.

  13. Catadioptric aberration correction in cathode lens microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tromp, R.M. [IBM T.J. Watson Research Center, PO Box 218, Yorktown Heights, NY 10598 (United States); Kamerlingh Onnes Laboratory, Leiden Institute of Physics, Niels Bohrweg 2, 2333 CA Leiden (Netherlands)

    2015-04-15

    In this paper I briefly review the use of electrostatic electron mirrors to correct the aberrations of the cathode lens objective lens in low energy electron microscope (LEEM) and photo electron emission microscope (PEEM) instruments. These catadioptric systems, combining electrostatic lens elements with a reflecting mirror, offer a compact solution, allowing simultaneous and independent correction of both spherical and chromatic aberrations. A comparison with catadioptric systems in light optics informs our understanding of the working principles behind aberration correction with electron mirrors, and may point the way to further improvements in the latter. With additional developments in detector technology, 1 nm spatial resolution in LEEM appears to be within reach. - Highlights: • The use of electron mirrors for aberration correction in LEEM/PEEM is reviewed. • A comparison is made with similar systems in light optics. • Conditions for 1 nm spatial resolution are discussed.

  14. Catadioptric aberration correction in cathode lens microscopy

    International Nuclear Information System (INIS)

    In this paper I briefly review the use of electrostatic electron mirrors to correct the aberrations of the cathode lens objective lens in low energy electron microscope (LEEM) and photo electron emission microscope (PEEM) instruments. These catadioptric systems, combining electrostatic lens elements with a reflecting mirror, offer a compact solution, allowing simultaneous and independent correction of both spherical and chromatic aberrations. A comparison with catadioptric systems in light optics informs our understanding of the working principles behind aberration correction with electron mirrors, and may point the way to further improvements in the latter. With additional developments in detector technology, 1 nm spatial resolution in LEEM appears to be within reach. - Highlights: • The use of electron mirrors for aberration correction in LEEM/PEEM is reviewed. • A comparison is made with similar systems in light optics. • Conditions for 1 nm spatial resolution are discussed

  15. A Luneburg lens in moving coordinates

    Science.gov (United States)

    Gladyshev, V. O.; Tereshin, A. A.

    2016-05-01

    The reflection of light rays by a reference microsatellite of new design, which moves with a velocity of 7500 m/s along a near-Earth orbit with a radius of 835 km, is calculated. The microsatellite is a bilayer Luneburg lens with an outer radius of 85 mm. The process of propagation of electromagnetic radiation in a Luneburg lens is analyzed for the first time with the effects of electrodynamics of moving media and optical glass dispersion taken into account. It is demonstrated that the lens motion leads to additional deflection and mixing of rays with various angles of incidence. The obtained results allow one to improve the accuracy of determination of satellite coordinates and open up new opportunities for tests of the theory of relativity and electrodynamics.

  16. Evaluation of Anterior Segment Parameter Changes Using the Sirius after Uneventful Phacoemulsification

    Science.gov (United States)

    Şimşek, Ali; Çapkın, Musa; Bilak, Şemsettin; Güler, Mete; Reyhan, Ali Hakim

    2016-01-01

    Purpose To investigate changes in anterior chamber depth (ACD), corneal volume (CV), anterior chamber angle (ACA), anterior chamber volume (ACV), central corneal thickness (CCT), horizontal visible iris diameter (HVID), pupil diameter (PD), and intraocular pressure (IOP) after uneventful phacoemulsification cataract surgery with intraocular lens implantation. Methods A total of 132 eyes of 132 patients (87 men and 45 women) that underwent uneventful phacoemulsification cataract surgery and intraocular lens implantation were prospectively studied. The mean age of the patients was 63.68 ± 12.51 years. All patients were evaluated preoperatively and at 1 month postoperatively with the Sirius 3D Rotating Scheimpflug camera topography system. The ACD, CV, ACA, ACV, CCT, HVID, and PD measurements were recorded. IOP was measured using the Goldmann applanation tonometer, which was corrected for CCT of the Sirius device using Ehlers' formula. Results The preoperative mean ACD, ACV, ACA, CCT, CV, PD, HVID, and IOP were 2.79 ± 0.45 mm, 124.73 ± 25.72 mm3, 42.09 ± 7.490, 523.87 ± 41.97 microns, 55.37 ± 4.89 mm3, 3.98 ± 1.23 mm, 11.72 ± 0.67 mm, and 14.74 ± 2.59 mmHg, respectively. Three months postoperatively, the mean ACD, ACV, ACA, CCT, CV, PD, HVID, and IOP were 3.45 ± 0.6 mm, 162.52 ± 23.79 mm3, 51.46 ± 5.630, 526.21 ± 44.45 microns, 56.23 ± 5.12 mm3, 2.87 ± 0.45 mm, 11.91 ± 0.75 mm, and 12.02 ± 1.83 mmHg, respectively. There was a statistically significant increase in mean postoperative ACD, ACV, ACA, CV, and HVID compared with the corresponding preoperative values (p 3D Rotating Scheimpflug camera topography system might help surgeons to predict postoperative changes resulting from phacoemulsification and intraocular lens implantation. This is a noncontact, noninvasive, and comfortable system for patients that is highly reliable and repeatable for anterior segment measurements. PMID:27478351

  17. Evaluation of Anterior Segment Parameter Changes Using the Sirius after Uneventful Phacoemulsification

    Science.gov (United States)

    Şimşek, Ali; Çapkın, Musa; Bilak, Şemsettin; Güler, Mete; Reyhan, Ali Hakim

    2016-01-01

    Purpose To investigate changes in anterior chamber depth (ACD), corneal volume (CV), anterior chamber angle (ACA), anterior chamber volume (ACV), central corneal thickness (CCT), horizontal visible iris diameter (HVID), pupil diameter (PD), and intraocular pressure (IOP) after uneventful phacoemulsification cataract surgery with intraocular lens implantation. Methods A total of 132 eyes of 132 patients (87 men and 45 women) that underwent uneventful phacoemulsification cataract surgery and intraocular lens implantation were prospectively studied. The mean age of the patients was 63.68 ± 12.51 years. All patients were evaluated preoperatively and at 1 month postoperatively with the Sirius 3D Rotating Scheimpflug camera topography system. The ACD, CV, ACA, ACV, CCT, HVID, and PD measurements were recorded. IOP was measured using the Goldmann applanation tonometer, which was corrected for CCT of the Sirius device using Ehlers' formula. Results The preoperative mean ACD, ACV, ACA, CCT, CV, PD, HVID, and IOP were 2.79 ± 0.45 mm, 124.73 ± 25.72 mm3, 42.09 ± 7.490, 523.87 ± 41.97 microns, 55.37 ± 4.89 mm3, 3.98 ± 1.23 mm, 11.72 ± 0.67 mm, and 14.74 ± 2.59 mmHg, respectively. Three months postoperatively, the mean ACD, ACV, ACA, CCT, CV, PD, HVID, and IOP were 3.45 ± 0.6 mm, 162.52 ± 23.79 mm3, 51.46 ± 5.630, 526.21 ± 44.45 microns, 56.23 ± 5.12 mm3, 2.87 ± 0.45 mm, 11.91 ± 0.75 mm, and 12.02 ± 1.83 mmHg, respectively. There was a statistically significant increase in mean postoperative ACD, ACV, ACA, CV, and HVID compared with the corresponding preoperative values (p < 0.05). CCT remained stable after surgery. Postoperative PD and IOP were significantly decreased compared to corresponding preoperative values (p < 0.05). Conclusions Preoperative measurements by the Sirius 3D Rotating Scheimpflug camera topography system might help surgeons to predict postoperative changes resulting from phacoemulsification and intraocular lens implantation. This is a

  18. Anterior Shoulder Instability with Concomitant Superior Labrum from Anterior to Posterior (SLAP) Lesion Compared to Anterior Instability without SLAP Lesion

    Science.gov (United States)

    Durban, Claire Marie C.; Kim, Je Kyun; Kim, Sae Hoon

    2016-01-01

    Background The aims of this study were to investigate the clinical characteristics of patients with combined anterior instability and superior labrum from anterior to posterior (SLAP) lesions, and to analyze the effect of concomitant SLAP repair on surgical outcomes. Methods We retrospectively reviewed patients who underwent arthroscopic stabilization for anterior shoulder instability between January 2004 and March 2013. A total of 120 patients were available for at least 1-year follow-up. Forty-four patients with reparable concomitant detached SLAP lesions (group I) underwent combined SLAP and anterior stabilization, and 76 patients without SLAP lesions (group II) underwent anterior stabilization alone. Patient characteristics, preoperative and postoperative pain scores, Rowe scores, and shoulder ranges of motion were compared between the 2 groups. Results Patients in group I had higher incidences of high-energy trauma (p = 0.03), worse preoperative pain visual analogue scale (VAS) (p = 0.02), and Rowe scores (p = 0.04). The postoperative pain VAS and Rowe scores improved equally in both groups without significant differences. Limitation in postoperative range of motion was similar between the groups (all p-value > 0.05). Conclusions Anterior instability with SLAP lesion may not be related to frequent episodes of dislocation but rather to a high-energy trauma. SLAP fixation with anterior stabilization procedures did not lead to poor functional outcomes if appropriate surgical techniques were followed. PMID:27247742

  19. Eye lens dose in interventional cardiology.

    Science.gov (United States)

    Principi, S; Delgado Soler, C; Ginjaume, M; Beltran Vilagrasa, M; Rovira Escutia, J J; Duch, M A

    2015-07-01

    The ICRP has recently recommended reducing the occupational exposure dose limit for the lens of the eye to 20 mSv y(-1), averaged over a period of 5 y, with no year exceeding 50 mSv, instead of the current 150 mSv y(-1). This reduction will have important implications for interventional cardiology and radiology (IC/IR) personnel. In this work, lens dose received by a staff working in IC is studied in order to determine whether eye lens dose monitoring or/and additional radiological protection measures are required. Eye lens dose exposure was monitored in 10 physicians and 6 nurses. The major IC procedures performed were coronary angiography and percutaneous transluminal coronary angioplasty. The personnel were provided with two thermoluminescent dosemeters (TLDs): one calibrated in terms of Hp(3) located close to the left ear of the operator and a whole-body dosemeter calibrated in terms of Hp(10) and Hp(0.07) positioned on the lead apron. The estimated annual eye lens dose for physicians ranged between 8 and 60 mSv, for a workload of 200 procedures y(-1). Lower doses were collected for nurses, with estimated annual Hp(3) between 2 and 4 mSv y(-1). It was observed that for nurses the Hp(0.07) measurement on the lead apron is a good estimate of eye lens dose. This is not the case for physicians, where the influence of both the position and use of protective devices such as the ceiling shield is very important and produces large differences among doses both at the eyes and on the thorax. For physicians, a good correlation between Hp(3) and dose area product is shown. PMID:25809107

  20. Intraocular Lens Calcification; a Clinicopathologic Report

    Directory of Open Access Journals (Sweden)

    Mozhgan Rezaei-Kanavi

    2009-04-01

    Full Text Available

    PURPOSE: To describe the clinical and pathological features of a case of hydrogel intraocular lens (IOL calcification. CASE REPORT: A 48-year-old man underwent explantation of a single-piece hydrophilic acrylic intraocular lens in his left eye because of decreased visual acuity and milky white opalescence of the IOL. The opacified lens was exchanged uneventfully with a hydrophobic acrylic IOL. Gross examination of the explanted IOL disclosed opacification of the optic and haptics. Full-thickness sections of the lens optic were stained with hematoxylin and eosin (H&E, von Kossa and Gram Tworts'. Microscopic examination of the sections revealed fine and diffuse basophilic granular deposits of variable size within the lens optic parallel to the lens curvature but separated from the surface by a moderately clear zone. The deposits were of high calcium content as evident by dark brown staining with von Kossa. Gram Tworts' staining disclosed no microorganisms. CONCLUSION: This report further contributes to the existing literature on hydrogel IOL calcification.

  1. Analytic Models of Plausible Gravitational Lens Potentials

    Energy Technology Data Exchange (ETDEWEB)

    Baltz, Edward A.; Marshall, Phil; Oguri, Masamune

    2007-05-04

    Gravitational lenses on galaxy scales are plausibly modeled as having ellipsoidal symmetry and a universal dark matter density profile, with a Sersic profile to describe the distribution of baryonic matter. Predicting all lensing effects requires knowledge of the total lens potential: in this work we give analytic forms for that of the above hybrid model. Emphasizing that complex lens potentials can be constructed from simpler components in linear combination, we provide a recipe for attaining elliptical symmetry in either projected mass or lens potential.We also provide analytic formulae for the lens potentials of Sersic profiles for integer and half-integer index. We then present formulae describing the gravitational lensing effects due to smoothly-truncated universal density profiles in cold dark matter model. For our isolated haloes the density profile falls off as radius to the minus fifth or seventh power beyond the tidal radius, functional forms that allow all orders of lens potential derivatives to be calculated analytically, while ensuring a non-divergent total mass. We show how the observables predicted by this profile differ from that of the original infinite-mass NFW profile. Expressions for the gravitational flexion are highlighted. We show how decreasing the tidal radius allows stripped haloes to be modeled, providing a framework for a fuller investigation of dark matter substructure in galaxies and clusters. Finally we remark on the need for finite mass halo profiles when doing cosmological ray-tracing simulations, and the need for readily-calculable higher order derivatives of the lens potential when studying catastrophes in strong lenses.

  2. Eye lens dose in interventional cardiology

    International Nuclear Information System (INIS)

    The ICRP has recently recommended reducing the occupational exposure dose limit for the lens of the eye to 20 mSv y-1 , averaged over a period of 5 y, with no year exceeding 50 mSv, instead of the current 150 mSv y-1 . This reduction will have important implications for interventional cardiology and radiology (IC/IR) personnel. In this work, lens dose received by a staff working in IC is studied in order to determine whether eye lens dose monitoring or/and additional radiological protection measures are required. Eye lens dose exposure was monitored in 10 physicians and 6 nurses. The major IC procedures performed were coronary angiography and percutaneous transluminal coronary angioplasty. The personnel were provided with two thermoluminescent dosemeters (TLDs): one calibrated in terms of Hp(3) located close to the left ear of the operator and a whole-body dosemeter calibrated in terms of Hp(10) and Hp(0.07) positioned on the lead apron. The estimated annual eye lens dose for physicians ranged between 8 and 60 mSv, for a workload of 200 procedures y-1. Lower doses were collected for nurses, with estimated annual Hp(3) between 2 and 4 mSv y-1. It was observed that for nurses the Hp(0.07) measurement on the lead apron is a good estimate of eye lens dose. This is not the case for physicians, where the influence of both the position and use of protective devices such as the ceiling shield is very important and produces large differences among doses both at the eyes and on the thorax. For physicians, a good correlation between Hp(3) and dose area product is shown. (authors)

  3. Capsule endoscopy in the diagnosis of Crohn’s disease

    Directory of Open Access Journals (Sweden)

    Niv Y

    2013-05-01

    Full Text Available Yaron NivDepartment of Gastroenterology, Rabin Medical Center, Tel Aviv University, Petah Tikva, IsraelAbstract: Crohn’s disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn’s disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn’s disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn’s disease. Recently, we have developed and validated the Capsule Endoscopy Crohn’s Disease Activity Index (also known as the Niv score for Crohn’s disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn’s ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing

  4. Finding the solution for incomplete small bowel capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    José; Cotter; Francisca; Dias; de; Castro; Joana; Magalhes; Maria; Joo; Moreira; Bruno; Rosa

    2013-01-01

    AIM:To evaluate whether the use of real time viewer(RTV)and administration of domperidone to patients with delayed gastric passage of the capsule could reduce the rate of incomplete examinations(IE)and improve the diagnostic yield of small bowel capsule endoscopy(SBCE).METHODS:Prospective single center interventional study,from June 2012 to February 2013.Capsule location was systematically checked one hour after ingestion using RTV.If it remained in the stomach,the patient received 10 mg domperidone per os and the location of the capsule was rechecked after 30 min.If the capsule remained in the stomach a second dose of10 mg of domperidone was administered orally.After another 30 min the position was rechecked and if the capsule remained in the stomach,it was passed into the duodenum by upper gastrointestinal(GI)endoscopy.The rate of IE and diagnostic yield of SBCE were compared with those of examinations performed before the use of RTV or domperidone in our Department(control group,January 2009-May 2012).RESULTS:Both groups were similar regarding age,sex,indication,inpatient status and surgical history.The control group included 307 patients,with 48(15.6%)IE.The RTV group included 82 patients,with3(3.7%)IE,P=0.003.In the control group,average gastric time was significantly longer in patients with IE than in patients with complete examination of the small bowel(77 min vs 26 min,P=0.003).In the RTV group,the capsule remained in the stomach one hour after ingestion in 14/82 patients(17.0%)vs 48/307(15.6%)in the control group,P=0.736.Domperidone did not significantly affect small bowel transit time(260min vs 297 min,P=0.229).The capsule detected positive findings in 39%of patients in the control group and 49%in the RTV group(P=0.081).CONCLUSION:The use of RTV and selective administration of domperidone to patients with delayed gastric passage of the capsule significantly reduces incomplete examinations,with no effect on small bowel transit time or diagnostic yield.

  5. The double capsules in macro-textured breast implants.

    Science.gov (United States)

    Giot, Jean-Philippe; Paek, Laurence S; Nizard, Nathanael; El-Diwany, Mostafa; Gaboury, Louis A; Nelea, Monica; Bou-Merhi, Joseph S; Harris, Patrick G; Danino, Michel A

    2015-10-01

    Breast implants are amongst the most widely used types of permanent implants in modern medicine and have both aesthetic and reconstructive applications with excellent biocompatibility. The double capsule is a complication associated with textured prostheses that leads to implant displacement; however, its etiology has yet to be elucidated. In this study, 10 double capsules were sampled from breast expander implants for in-depth analysis; histologically, the inner capsular layer demonstrated highly organized collagen in sheets with delamination of fibers. At the prosthesis interface (PI) where the implant shell contacts the inner capsular layer, scanning electron microscopy (SEM) revealed a thin layer which mirrored the three-dimensional characteristics of the implant texture; the external surface of the inner capsular layer facing the intercapsular space (ICS) was flat. SEM examination of the inner capsule layer revealed both a large bacterial presence as well as biofilm deposition at the PI; a significantly lower quantity of bacteria and biofilm were found at the ICS interface. These findings suggest that the double capsule phenomenon's etiopathogenesis is of mechanical origin. Delamination of the periprosthetic capsule leads to the creation of the ICS; the maintained separation of the 2 layers subsequently alters the biostability of the macro-textured breast implant.

  6. FEM analysis of escape capsule suffered to gas explosion

    Science.gov (United States)

    Li, Chang-lu; Mei, Rui-bin; Li, Chang-sheng; Cai, Ban; Liu, Xiang-hua

    2013-05-01

    Escape capsules are new devices for underground coal mines that provide air, water, food and supplies in the event of an emergency in where miners are unable to escape. It is difficult to carry out the experiments of explosion and safety because the danger and nonrepeatability of explosion. The structure deformation and distribution of equivalent stress has been investigated under different impact pressure conditions including unimodal and bimodal loads based on the FEM and software LS-DYNA. The results show that the distribution of deformation and equivalent stress has the same trend on the same surface with the increment of explosion pressure. The deformation and stress are larger with side impact pressure compared with that of the same front impact pressure. Furthermore, the maximum equivalent stress is 246MPa and 260MPa on the front and sides of capsule with five times for national standard impact pressure 1.5MPa. Under these conditions, the deformation is less than about 9.97mm and 10.47mm, respectively. When the front impact pressure is 2.0MPa, the deformation of capsule still belongs to elasticity but the less plastic deformation occurs on the Ushape stiffening channels with the same side impact pressure. However, it is safe for capsule structure because the equivalent stress 283MPa is much less than the tensile strength. It is noted that bimodal load accelerates the capsule deformation so that it is more dangerous compared with unimodal load.

  7. Wireless powered capsule endoscopy for colon diagnosis and treatment

    International Nuclear Information System (INIS)

    This paper presents a wireless power transfer system integrated with an active locomotion and biopsy module in an endoscopic capsule for colon inspection. The capsule, which can move automatically, is designed for non-invasive biopsy and visual inspection of the intestine. To supply enough power for multiple functions and ensure safety for the human body, the efficiency of the current power transmission system needs to be improved. To take full advantage of the volume in the capsule body, a novel structure of receiving coils wound on a multi-core of MnZn ferrite hollow cylinder was used; with this new core, the efficiency increased to more than 7.98%. Up to 1.4 W of dc power can be delivered to the capsule as it travels along the gastrointestinal tract. Three micro motors were integrated for pumping, anchoring, locomotion and biopsy. A user interface and RF communication enables the operator to drive the capsule in an intuitive manner. To gauge the efficacy of the wireless power supply in a simulated real-world application, the biopsy and locomotion capabilities of the device were successfully tested in a slippery, soft tube and gut environment in vitro. (paper)

  8. Improvement and utilization of irradiation capsule technology in HANARO

    International Nuclear Information System (INIS)

    Several improvements of irradiation capsule technology regarding irradiation test parameters, such as temperature and neutron flux/fluence, and regarding instrumentation have progressed at HANARO since the last KAERI-JAERI joint seminar held in 2008. The standard HANARO capsule technology that was developed for use in a commercial power plant temperature of about 300degC was improved to apply to a temperature range of 100-1000degC for the irradiation test of materials of new research reactors and future nuclear systems. Low-flux and long-term irradiation technologies have been developed at HANARO. As a beginning step of the localization of capsule instrumentation technology, the irradiation performance of a domestically produced thermocouple and LVDT will be examined at HANARO. The accuracy of an evaluation of neutron fluence and precise welding technology are also being examined at HANARO. Based on these accumulated capsule technologies, a HANARO irradiation capsule system is being actively utilized for the national R and D programme on commercial nuclear reactors and nuclear fuel cycle technology in Korea. HANARO has recently started the irradiation support of R and D relevant to future nuclear systems including SMART, VHTR, and SFR, and HANARO is preparing new support relevant to new research and Fusion reactors. (author)

  9. Thermohydraulic design of saturated temperature capsule for IASCC irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Ide, Hiroshi; Matsui, Yoshinori; Itabashi, Yukio [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2002-10-01

    An advanced water chemistry controlled irradiation research device is being developed in JAERI, to perform irradiation tests for irradiation assisted stress corrosion cracking (IASCC) research concerned with aging of LWR. This device enables the irradiation tests under the water chemistry condition and the temperature, which simulate the conditions for BWR core internals. The advanced water chemistry controlled irradiation research device is composed of saturated temperature capsule inserted into the JMTR core and the water chemistry control unit installed in the reactor building. Regarding the saturated temperature capsule, the Thermohydraulic design of capsule structure was done, aimed at controlling the specimen's temperature, feeding water velocity on specimen's surface to the environment of BWR nearer. As the result of adopting the new capsule structure based on the design study, it was found out that feeding water velocity at the surface of specimen's is increased to about 10 times as much as before, and nuclear heat generated in the capsule components can be removed safely even in the abnormal event such as the case of loss of feeding water. (author)

  10. FTIR-ATR imaging of coated oil capsules

    International Nuclear Information System (INIS)

    Complete text of publication follows. Coated oil capsules are used to deliver new functional food ingredients. In this study spherical capsules were investigated containing a core with fish oil coated with a transparent gelatine layer. The remaining actives are within a hard coating, which is applied on the gelatine capsules. For the microstructural characterization of the coating the following techniques were used: Fourier Transform Infrared (FTIR) microscopy using an Attenuated Total Reflection (ATR) crystal, Light Microscopy (LM), X-ray microtomography (μCT) and Scanning Electron Microscopy (SEM). For FTIR-ATR imaging the oil capsules were embedded in epoxy resin. The embedded sample was trimmed in a microtome using a glass knife for the initial rough trimming. For the final fracture a diamond knife was used to obtain the best possible surface. A Ge-crystal was brought in contact with the surface of interest. LM images were obtained using the visible light camera of the FTIR system. A principal component analysis was performed on the FTIR-ATR imaging showing the spatial distribution of some of the compounds. This study demonstrated that imaging techniques can be used to analyse the microstructure of coated oil capsules. Correlative microscopy of techniques like FTIR-ATR imaging, LM, XRT and SEM-EDX results in useful information about the spatial distribution of the chemical compounds and layer thickness of solid food samples.

  11. Fabrication of an unusual mosaic lens

    International Nuclear Information System (INIS)

    The design philosophy and the construction techniques to make a novel mosaic lens to collect Cerenkow radiation are described. The lens blanks were rough cut into segments by a water jet. The segments were cut to the final inner and outer diameters by ultrasonically assisted machining, an unusual new technique developed at the Los Alamos National Laboratory. The technology will soon be available to the public through Sonic Mill, Inc., 3820 Academy Parkway North, NE, Albuquerque, N.M. 87109. The advantage of ultrasonically assisted machining lies in rapid, accurate shaping of brittle materials such as ceramics and glass, which can by this technique, be shaped about as fast as aluminum

  12. Time resolved thermal lens in edible oils

    Science.gov (United States)

    Albuquerque, T. A. S.; Pedreira, P. R. B.; Medina, A. N.; Pereira, J. R. D.; Bento, A. C.; Baesso, M. L.

    2003-01-01

    In this work time resolved thermal lens spectrometry is applied to investigate the optical properties of the following edible oils: soya, sunflower, canola, and corn oils. The experiments were performed at room temperature using the mode mismatched thermal lens configuration. The results showed that when the time resolved procedure is adopted the technique can be applied to investigate the photosensitivity of edible oils. Soya oil presented a stronger photochemical reaction as compared to the other investigated samples. This observation may be relevant for future studies evaluating edible oils storage conditions and also may contribute to a better understanding of the physical and chemical properties of this important foodstuff.

  13. Sterilization potential of contact lens solutions

    Directory of Open Access Journals (Sweden)

    Dada Vijay

    1988-01-01

    Full Text Available In a dynamic field of Contact Lens Solutions maintenance of high standards of anti-microbial activity is a must Resterilization Activity Time′ is a universally accepted yardstick for such an evaluation. In this study eight brands of indigenous popular solutions alongwith two FDA approved solutions were tested for their sterilization efficacy: Standardized suspensions of Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans and Aspergillus fumigatus were used for the purpose. It was observed that the contact lens solutions available ir, the domestic market were not upto the mark Suggestions for improvement have also been made.

  14. Bilateral Pseudoexfoliation Deposits on Intraocular Lens Implants

    Directory of Open Access Journals (Sweden)

    Elena Bonafonte Marquez

    2015-01-01

    Full Text Available We present a rare case of bilateral pseudoexfoliative deposits on both intraocular lens (IOL implants in an 83-year-old woman with no other associated pathology, 5 years after cataract surgery. Pseudoexfoliation syndrome is the most common cause of secondary open-angle glaucoma worldwide and these deposits are usually found on the natural lens. The fact that pseudoexfoliative deposits have been found on IOL implants implies the need for a thorough examination in pseudophakic patients, for it could be the only sign of secondary glaucoma.

  15. Coherent diffraction imaging by moving a lens.

    Science.gov (United States)

    Shen, Cheng; Tan, Jiubin; Wei, Ce; Liu, Zhengjun

    2016-07-25

    A moveable lens is used for determining amplitude and phase on the object plane. The extended fractional Fourier transform is introduced to address the single lens imaging. We put forward a fast algorithm for the transform by convolution. Combined with parallel iterative phase retrieval algorithm, it is applied to reconstruct the complex amplitude of the object. Compared with inline holography, the implementation of our method is simple and easy. Without the oversampling operation, the computational load is less. Also the proposed method has a superiority of accuracy over the direct focusing measurement for the imaging of small size objects. PMID:27464107

  16. Rotman lens for mm-wavelengths

    Science.gov (United States)

    Hall, Leonard T.; Hansen, Hedley J.; Abbott, Derek

    2002-11-01

    The 77 GHz band has been reserved for intelligent cruise control in luxury cars and some public transport services in America and the United Kingdom. The Rotman lens offers a cheap and compact means to extend the single beam systems generally used, to fully functional beam staring arrangements. Rotman lenses have been built for microwave frequencies with limited success. The flexibility of microstrip transmission lines and the advent of fast accurate simulation packages allow practical Rotman lenses to be designed at mm-wavelengths. This paper discusses the limitations of the conventional design approach and predicts the performance of a new Rotman lens designed at 77 GHz.

  17. Pulse transformer for the AA lithium lens

    CERN Multimedia

    1980-01-01

    The antiprotons emanating from the target were initially focused by a magnetic horn. Later on, a Li-lens was used during operation for the SPS collider, until 1992. A Li-rod (130 mm long, 34 mm in diameter) constituted the secondary of a 1:23 pulse-transformer. The half-sine pulse rose to 1000 kA in 900 microsec. The angular acceptance was 95 mrad. In operation after 1992, for LEAR only, a more modest Li-lens was used (155 mm long, diameter 20 mm, 480 kA, risetime 240 microsec, angular acceptance 75 mrad).

  18. The effect of glicerol and sorbitol plasticizers toward disintegration time of phyto-capsules

    Science.gov (United States)

    Pudjiastuti, Pratiwi; Hendradi, Esti; Wafiroh, Siti; Harsini, Muji; Darmokoesoemo, Handoko

    2016-03-01

    The aim of research is determining the effect of glycerol and sorbitol toward the disintegration time of phyto-capsules, originated capsules from plant polysaccharides. Phyto-capsules were made from polysaccharides and 0.5% (v/v) of glycerol and sorbitol of each. The seven capsules of each were determined the disintegration time using Erweka disintegrator. The mean of disintegration time of phyto-capsules without plasticizers, with glycerol and sorbitol were 25'30"; 45'15" and 35'30" respectively. The color and colorless gelatin capsules showed the mean of disintegration time 7'30" and 2'35" respectively.

  19. Iris Claw versus Scleral Fixation Intraocular Lens Implantation during Pars Plana Vitrectomy

    Directory of Open Access Journals (Sweden)

    Fereydoun Farrahi

    2012-01-01

    Full Text Available Purpose: To compare the outcomes of iris claw anterior chamber intraocular lens (ICACIOL with that of scleral fixation posterior chamber intraocular lens (SF-PCIOL implantation during pars plana vitrectomy (PPV as initial surgery to correct aphakia. Methods: Twelve patients with complicated cataract surgery or trauma who had suffered nucleus, whole crystalline lens or intraocular lens (IOL drop into the vitreous cavity, and undergone PPV with IC-ACIOL implantation over a period of one year were evaluated for the purpose of this study. Uncorrected visual acuity (UCVA, best corrected visual acuity (BCVA, central corneal thickness (CCT, spherical equivalent (SE refractive error, astigmatism and complications were recorded. The results were compared to outcomes of another group of 13 patients who had previously undergone PPV with SF-PCIOL implantation. Results: Mean improvement of UCVA was greater in IC-ACIOL eyes as compared to the SF-PCIOL group (-1.17±0.28 versus -0.89±0.21 logMAR, P=0.01, corresponding values for postoperative BCVA were 0.24±0.17 and 0.44±0.22 logMAR (P=0.041, respectively. Average postoperative SE was comparable in the IC-ACIOL and SFPCIOL groups at 0.6±1.03 and 0.56±1.23 diopters, respectively (P=0.290. However, 10 (83.3% IC-ACIOL eyes versus 6 (46.1% SF-PCIOL eyes had SE within 1 diopter of emmetropia (P=0.048. Mean postoperative increase in CCT was comaparble between the study groups (P=0.126. Conclusion: In the absence of sufficient capsular support, the use of an IC-ACIOL for correction of aphakia during PPV can be a good alternative and seems to entail better visual outcomes as compared to SF-PCIOL.

  20. 可植入接触镜屈光手术后调节与拱高的关系%Relationship between accommodation and lens vault following implantable contact lens surgery

    Institute of Scientific and Technical Information of China (English)

    赖晓娟; 李志敏; 谷浩

    2014-01-01

    Background Implantable contact lens (ICL) surgery is a primary intraocular refractive corrective surgery for high myopia.However,whether there will be enough distance between ICL and anterior face of lens to avoid the occurrence of anterior capsular cataract in non-accommodated and the largest physiological accommodated state after ICL implantation is worthy of investigation.Objective The purpose of this study was to investigate the alteration of lens vault after ICL implantation and explore the relationship between accommodation and change of lens vault.Methods A observational study was carried out.Sixty-six eyes of 33 patients with high myopia who received ICL implantation were enrolled in Affiliated First Hospital of Guiyang Medical College from May to November,2012.Best corrected visual acuity (BCVA),uncorrected visual acuity (UCVA),refractive diopter were regularly examined using synthetical optometry,and crystalline lens rise (CLR) and lens vault in non-accommodative or accommodative condition were observed by the anterior segment OCT (Visante OCT) and ultrasound biomicoscopy (UBM) before operation and 1 day,1 week,l month and 3 months after operation.Data were analyzed with SPSS version 16.0.Repeated measurement one-way analysis of variance was used to compare the differences of vision and refractive diopter among various time points.The relationship between accommodation and CLR was assessed using Pearson linear correlation.The alteration of CLR with accommodation change was analyzed by linear regression equation.Lens vault was measured and compared between non-accommodation and maximal physical accommodation status by paired t test.Results The postoperative UCVA was improved in comparison with preoperative BCVA,and the postoperative diopter was significantly lower than that of preoperation,with significant differences among various time points (F =16.904,P =0.000 ; F =1.498,P =0.000),and the diopter was stable after operation.A positive correlation was