Sample records for anterior lens capsule

  1. Treatment Approach to Small Inadvertent Injury of the Crystalline Lens Anterior Capsule During Iridodialysis Repair Surgery

    Directory of Open Access Journals (Sweden)

    Gökçen Gökçe

    2013-01-01

    Full Text Available A 22-year-old man presented to our ophthalmology department with photophobia. On ophthalmic examination, iridodialysis secondary to blunt trauma that occurred 5 years ago was diagnosed. During iridodialysis repair surgery, long curved double-armed needle of 10-0 polypropylene suture (PC-9 inserted into the 19 gauge side port turned down inadvertently by its own weight, resulting in crystalline lens anterior capsule perforation. Postoperative clinical observation revealed no lens opacification affecting visual acuity. This case report showed that lens aspiration surgery should be postponed if the capsule injury is small.(Turk J Ophthalmol 2013; 43: 61-3

  2. The method for staining of anterior lens capsule in cases with small and rigid pupils

    Directory of Open Access Journals (Sweden)

    V. Kumar

    2012-01-01

    Full Text Available Purpose: to evaluate the safety and effectiveness of proposed method for staining with trypan blue anterior lens capsule in cases with small and rigid pupils.Methods: the safety and effectiveness of the proposed method was evaluated in 169 cases having small and rigid pupils of III and IV grade. Surgical steps included: irrigation of anterior chamber with small amount of air, enough to block the pupil; irrigation of posterior chamber with little amount of dye followed by aspiration of air bubble. the excess dye came out and stained the capsule in pupillary area.Results: No difficulty was encountered in irrigating the posterior chamber with dye. Uneven staining of the capsule was noticed in 16 cases (9.5%. In 3 cases (1.8% extensive staining of iris and posterior capsule was observed. Continuous curvilinear capsulorhexis was performed successfully in 97.6% cases. In 4 cases there was radial run of the rhexis extending up to posterior capsule. Postopera- tive inflammation of 1st and 2nd degree was observed in 5.9 and 23.1% cases, which was related to unavoidable trauma to iris tissue during pupil stretching.Conclusion: the proposed method of capsule staining in cases with small and rigid pupils is safe and effective.

  3. The method for staining of anterior lens capsule in cases with small and rigid pupils

    Directory of Open Access Journals (Sweden)

    V. Kumar

    2014-07-01

    Full Text Available Purpose: to evaluate the safety and effectiveness of proposed method for staining with trypan blue anterior lens capsule in cases with small and rigid pupils.Methods: the safety and effectiveness of the proposed method was evaluated in 169 cases having small and rigid pupils of III and IV grade. Surgical steps included: irrigation of anterior chamber with small amount of air, enough to block the pupil; irrigation of posterior chamber with little amount of dye followed by aspiration of air bubble. the excess dye came out and stained the capsule in pupillary area.Results: No difficulty was encountered in irrigating the posterior chamber with dye. Uneven staining of the capsule was noticed in 16 cases (9.5%. In 3 cases (1.8% extensive staining of iris and posterior capsule was observed. Continuous curvilinear capsulorhexis was performed successfully in 97.6% cases. In 4 cases there was radial run of the rhexis extending up to posterior capsule. Postopera- tive inflammation of 1st and 2nd degree was observed in 5.9 and 23.1% cases, which was related to unavoidable trauma to iris tissue during pupil stretching.Conclusion: the proposed method of capsule staining in cases with small and rigid pupils is safe and effective.

  4. Late anterior traumatic subluxation of a circular in-the-bag intraocular lens associated with lack of posterior capsule opacification.

    Science.gov (United States)

    Billotte, Christian; Stéfani, Pierre; Lecoq, Pierre

    2003-05-01

    We report a case of traumatic subluxation of a circular poly(methyl methacrylate) intraocular lens (IOL) 5 years after surgery. Slitlamp examination revealed the lack of epithelial cells or fibrosis in the intact capsule bag. Trauma was minor, and no other complication was found in the eye and orbit. The subluxated IOL was easily relocated in the bag with a hook, revealing the poor capsule sealing. Among the factors ensuring the fixation of IOLs placed in the bag after continuous curvilinear capsulotomy are sealing of the anterior and posterior capsules and proliferation of epithelial cells from the equator of the bag.

  5. Restoring lens capsule integrity enhances lens regeneration in New Zealand albino rabbits and cats.

    Science.gov (United States)

    Gwon, A; Gruber, L J; Mantras, C

    1993-11-01

    In studies conducted by numerous investigators for 150 years, lenses regenerated following endocapsular lens extraction in New Zealand albino rabbits have been irregular in shape, appearing primarily doughnut-shaped as a result of lack of lens growth at the site of the anterior capsulotomy and its adhesion to the posterior capsule. In the present study, we restored the lens capsule integrity by inserting a collagen patch at the time of surgery to seal the anterior capsulotomy and to improve the shape and structure of the regenerated lenses. We then filled the capsule bag with air to prevent adhesions between the anterior and posterior capsule and maintain capsule tautness and shape. Lens regeneration was first noted as early as one to two weeks. Regenerated lens filled approximately 50% of the capsule bag at two weeks and 100% by five weeks. Subsequent growth was in the anterior-posterior direction and measured by A-scan biometry. Lens thickness increased by 0.3 mm per month. The regenerated lenses were spherical with normal cortical structure and a nuclear opacity. In conclusion, restoration of lens capsular integrity with a collagen patch following endocapsular lens extraction enhanced the shape, structure, and growth rate of the regenerated lenses. In addition, lens regeneration was shown to occur in two cats.

  6. The Analysis of Intracellular and Intercellular Calcium Signaling in Human Anterior Lens Capsule Epithelial Cells with Regard to Different Types and Stages of the Cataract.

    Directory of Open Access Journals (Sweden)

    Marko Gosak

    Full Text Available In this work we investigated how modifications of the Ca2+ homeostasis in anterior lens epithelial cells (LECs are associated with different types of cataract (cortical or nuclear and how the progression of the cataract (mild or moderate affects the Ca2+ signaling. We systematically analyzed different aspects of intra- and inter-cellular Ca2+ signaling in the human LECs, which are attached to surgically isolated lens capsule (LC, obtained during cataract surgery. We monitored the temporal and spatial changes in intracellular Ca2+ concentration after stimulation with acetylcholine by means of Fura-2 fluorescence captured with an inverted microscope. In our analysis we compared the features of Ca2+ signals in individual cells, synchronized activations, spatio-temporal grouping and the nature of intercellular communication between LECs. The latter was assessed by using the methodologies of the complex network theory. Our results point out that at the level of individual cells there are no significant differences when comparing the features of the signals with regard either to the type or the stage of the cataract. On the other hand, noticeable differences are observed at the multicellular level, despite inter-capsule variability. LCs associated with more developed cataracts were found to exhibit a slower collective response to stimulation, a less pronounced spatio-temporal clustering of LECs with similar signaling characteristics. The reconstructed intercellular networks were found to be sparser and more segregated than in LCs associated with mild cataracts. Moreover, we show that spontaneously active LECs often operate in localized groups with quite well aligned Ca2+ activity. The presence of spontaneous activity was also found to affect the stimulated Ca2+ responses of individual cells. Our findings indicate that the cataract progression entails the impairment of intercellular signaling thereby suggesting the functional importance of altered Ca2

  7. Non-contact optical measurement of lens capsule thickness during simulated accommodation

    Science.gov (United States)

    Ziebarth, Noel; Manns, Fabrice; Acosta, Ana-Carolina; Parel, Jean-Marie

    2005-04-01

    Purpose: To non-invasively measure the thickness of the anterior and posterior lens capsule, and to determine if it significantly changes during accommodation. Methods: Anterior and posterior capsule thickness was measured on post-mortem lenses using a non-contact optical system using a focus-detection technique. The optical system uses a 670nm laser beam delivered to a single-mode fiber coupler. The output of the fiber coupler is focused on the tissue surface using an aspheric lens (NA=0.68) mounted on a translation stage with a motorized actuator. Light reflected from the sample surface is collected by the fiber coupler and sent to a photoreceiver connected to a computer-controlled data acquisition system. Optical intensity peaks are detected when the aspheric lens is focused on the capsule boundaries. The capsule thickness is equal to the distance traveled between two peaks multiplied by the capsule refractive index. Anterior and posterior lens capsule thickness measurements were performed on 18 cynomolgus (age average: 6+/-1 years, range: 4-7 years) eyes, 1 rhesus (age: 2 years) eye, and 12 human (age average: 65+/-16, range: 47-92) eyes during simulated accommodation. The mounted sample was placed under the focusing objective of the optical system so that the light was incident on the center pole. Measurements were taken of the anterior lens capsule in the unstretched and the stretched 5mm states. The lens was flipped, and the same procedure was performed for the posterior lens capsule. Results: The precision of the optical system was determined to be +/-0.5um. The resolution is 4um and the sensitivity is 52dB. The human anterior lens capsule thickness was 6.0+/-1.2um unstretched and 4.9+/-0.9um stretched (p=0.008). The human posterior lens capsule was 5.7+/-1.2um unstretched and 5.7+/-1.4um stretched (p=0.974). The monkey anterior lens capsule thickness was 5.9+/-1.9um unstretched and 4.8+/-1.0um stretched (p=0.002). The monkey posterior lens capsule was 5

  8. Noncontact optical measurement of lens capsule thickness ex vivo

    Science.gov (United States)

    Ziebarth, Noel M.; Manns, Fabrice; Uhlhorn, Stephen; Parel, Jean-Marie

    2004-07-01

    Purpose: To design a non-contact optical system to measure lens capsule thickness in cadaver eyes. Methods: The optical system uses a 670nm laser beam delivered to a single-mode fiber coupler. The output of the fiber coupler is focused onto the tissue using an aspheric lens (NA=0.68) mounted on a motorized translation stage. Light reflected from the sample is collected by the fiber coupler and sent to a silicon photodiode connected to a power meter. Peaks in the power signal are detected when the focal point of the aspheric lens coincides with the capsule boundaries. The capsule thickness is proportional to the distance between successive peaks. Anterior and posterior lens capsule thickness measurements were performed on 13 human, 10 monkey, and 34 New Zealand white rabbit lenses. The cadaver eyes were prepared for optical measurements by bonding a PMMA ring on the sclera. The posterior pole was sectioned, excess vitreous was removed, and the eye was placed on a Teflon slide. The cornea and iris were then sectioned. After the experiments, the lenses were excised, placed in 10% buffered formalin, and prepared for histology. Results: Central anterior lens capsule thickness was 9.4+/-2.9μm (human), 11.2+/-6.6μm (monkey), and 10.3+/-3.6μm (rabbit) optically and 14.9+/-1.6μm (human), 17.7+/-4.9μm (monkey), and 12.6+/-2.3μm (rabbit) histologically. The values for the central posterior capsule were 9.4+/-2.9μm (human), 6.6+/-2.5μm (monkey), and 7.9+/-2.3μm (rabbit) optically and 4.6+/-1.4μm (human), 4.5+/-1.2μm (monkey), and 5.7+/-1.7μm (rabbit) histologically. Conclusions: This study demonstrates that a non-contact optical system can successfully measure lens capsule thickness in cadaver eyes.

  9. Developmental anatomy in the zonular connection with lens capsule in macaque eye.

    Science.gov (United States)

    Hiraoka, Mari; Kuroda, Teiko; Inoue, Kenichi; Senoo, Haruki; Takada, Masahiko

    2013-05-01

    Morphological analyses of zonule conjugated with lens capsule were performed on the developmental change in eyes from the age of fetus to 7 years old of the rhesus macaques (Macaca fuscata). The zonule was filamentous network in late fetus. After birth, the zonular microfibrils originated from the nonpigmented epithelium of the ciliary process. On the extending path toward the lens capsule through the chamber, microfibril assembled with neighbor fibril and also cohered with one another forming bundle. With growth, these bundles bifurcated into anterior and posterior groups on the equatorial region of capsule. The developmental distribution of bundles in the capsule was characteristic on anterior group, that is, bifurcation into radial and circumferential extension. On the other hand, the posterior bundle undivided but radially extended within short distance from the equator. In the process of fixating with capsule, bundles untangled into fibrils and penetrated circumferentially into the superficial layer and radially into deep apical layer of the capsule. Zonule was composed fibrillin 1 microfibrils and on the extending path toward the lens capsule through the chamber, microfibril self-assembled with neighbored fibril in composition of fascicle and also cohered with one another forming bundle. Each bundle had alternating pale and dense horizontal bands in the intracapsular extension and the stripe pattern changed in flaccid or extensive tension of zonule between capsule and process. Zonular fibril intermingled with collagen fibril of capsule with interlacing molecule of laminin. At the base of ciliary muscle, elastin-positive connective tissue intercalated circumferentially between ciliary processes. The developmental changes of the intralamellar distribution and extension of zonule with striped pattern informed the functional role upon the elasticity in coordination with the lens capsule micromolecules. Copyright © 2013 Wiley Periodicals, Inc.

  10. Accuracy of 3 imaging modalities for evaluation of the posterior lens capsule in traumatic cataract.

    Science.gov (United States)

    Tabatabaei, Ali; Hasanlou, Narges; Kheirkhah, Ahmad; Mansouri, Mohammadreza; Faghihi, Houshang; Jafari, Hajar; Arefzadeh, Alireza; Moghimi, Sasan

    2014-07-01

    To compare the accuracy of 3 imaging modalities for preoperative evaluation of the posterior lens capsule in traumatic cataract. Farabi Eye Hospital, Tehran, Iran. Case series. The study comprised eyes with traumatic cataract opaque enough to prevent visualization of the posterior lens capsule on slitlamp examination. To detect posterior lens capsule rupture before surgery, imaging was performed with 20 MHz echography (Eye Cubed), anterior segment optical coherence tomography (AS-OCT) (Visante model 1000), and Scheimpflug imaging (Pentacam). All patients subsequently had cataract extraction, and the intraoperative findings of the posterior lens capsule were compared with the preoperative findings of the imaging modalities. The study enrolled 21 eyes of 21 patients (20 men, 1 woman) with a mean age of 31.5 years ± 1.45 (SD). The nature of trauma was blunt (5 eyes) or sharp (16 eyes). To detect posterior lens capsule rupture, the sensitivity and specificity were, respectively, 80% and 86% for 20 MHz echography, 71% and 77% for AS-OCT, and 62% and 57% for Scheimpflug imaging (95% confidence intervals: sensitivity, 30.00-90.32; specificity, 54.81-92.95). Insufficient resolution for posterior lens capsule evaluation occurred in 33.3% cases for AS-OCT and 57.1% cases for Scheimpflug imaging. The accuracy of 20 MHz echography, AS-OCT, and Scheimpflug imaging was 76.1%, 61.9%, and 42.9%, respectively. In the evaluation of the posterior lens capsule in eyes with traumatic cataract, 20 MHz echography had higher accuracy than AS-OCT and Scheimpflug imaging. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. All rights reserved.

  11. Lens stem cells may reside outside the lens capsule: an hypothesis

    Directory of Open Access Journals (Sweden)

    Meyer Rita A

    2007-06-01

    Full Text Available Abstract In this paper, we consider the ocular lens in the context of contemporary developments in biological ideas. We attempt to reconcile lens biology with stem cell concepts and a dearth of lens tumors. Historically, the lens has been viewed as a closed system, in which cells at the periphery of the lens epithelium differentiate into fiber cells. Theoretical considerations led us to question whether the intracapsular lens is indeed self-contained. Since stem cells generate tumors and the lens does not naturally develop tumors, we reasoned that lens stem cells may not be present within the capsule. We hypothesize that lens stem cells reside outside the lens capsule, in the nearby ciliary body. Our ideas challenge the existing lens biology paradigm. We begin our discussion with lens background information, in order to describe our lens stem cell hypothesis in the context of published data. Then we present the ciliary body as a possible source for lens stem cells, and conclude by comparing the ocular lens with the corneal epithelium.

  12. Investigation of lens morphology and mechanical characteristics of lens capsule and lens nucleus in patients with agerelated and diabetic cataract

    Directory of Open Access Journals (Sweden)

    A. S. Tishkova

    2014-07-01

    Full Text Available Purpose: To investigate the influence of carbohydrate metabolism on the structure and mechanical properties of the lens capsule and nucleus.Methods: Human lens pathology was studied in different forms of cataract. 220 patients with a cataract (220 eyes were included in this study. Morphological, immunohystological and immunocytochemical investigations of lens substance (antibodies to a- (a-А and a-В, b-, g- crystallines, spectroscopic analyses of smears and morphometric analyses of slices, investigation of lens morphology and mechanical caracteristics of lens capsule and lens nucleus were performed.Results: The capsule of the lens in patients with senile cataract contains more Na+, Cl-. The capsule of the lens in patients with senile cataract contains more Ca2+, O. Mechanical strength of the capsule in the case of diabetes mellitus was lower comparatively with senile cataract in the same age groups. More significant expression of a-В and b-crystallines was found in patients with diabetes mellitus comparatively with patients with age-related cataract. Morphological features were founded in patients with cortical and nuclear forms of senile cataract and the diabetic cataract.Conclusion: During surgery (ultrasonic microcoaxial phacoemulsification the equivalent of ultrasound was recorded. Lower density of the lens nucleus of patients with diabetes mellitus made it possible to use lower energy parameters. Using the torsion ultrasound in those cases allowed us to decrease the influence of ultrasound on eye tissues and reduce the time of achieving the maximum BCVA in the postsurgical period.

  13. Investigation of lens morphology and mechanical characteristics of lens capsule and lens nucleus in patients with agerelated and diabetic cataract

    Directory of Open Access Journals (Sweden)

    A. S. Tishkova

    2013-01-01

    Full Text Available Purpose: To investigate the influence of carbohydrate metabolism on the structure and mechanical properties of the lens capsule and nucleus.Methods: Human lens pathology was studied in different forms of cataract. 220 patients with a cataract (220 eyes were included in this study. Morphological, immunohystological and immunocytochemical investigations of lens substance (antibodies to a- (a-А and a-В, b-, g- crystallines, spectroscopic analyses of smears and morphometric analyses of slices, investigation of lens morphology and mechanical caracteristics of lens capsule and lens nucleus were performed.Results: The capsule of the lens in patients with senile cataract contains more Na+, Cl-. The capsule of the lens in patients with senile cataract contains more Ca2+, O. Mechanical strength of the capsule in the case of diabetes mellitus was lower comparatively with senile cataract in the same age groups. More significant expression of a-В and b-crystallines was found in patients with diabetes mellitus comparatively with patients with age-related cataract. Morphological features were founded in patients with cortical and nuclear forms of senile cataract and the diabetic cataract.Conclusion: During surgery (ultrasonic microcoaxial phacoemulsification the equivalent of ultrasound was recorded. Lower density of the lens nucleus of patients with diabetes mellitus made it possible to use lower energy parameters. Using the torsion ultrasound in those cases allowed us to decrease the influence of ultrasound on eye tissues and reduce the time of achieving the maximum BCVA in the postsurgical period.

  14. Under-air staining of the anterior capsule using Trypan blue with a 30 G needle

    Directory of Open Access Journals (Sweden)

    Giammaria D

    2013-01-01

    Full Text Available Daniele Giammaria,1 Michele Giannotti,2 Angelo Scopelliti,1 Giacomo Pellegrini,1 Bruno Giannotti11Azienda Ospedaliera Ospedali Riuniti Marche Nord, Fano, Italy; 2Catholic University of Rome, Rome, ItalyAbstract: The original technique of staining the anterior capsule of the lens with Trypan blue involves the injection of an air bubble in the anterior chamber. A drawback of this technique is the possible instability of the anterior chamber caused by the sudden exit of air when the dye is injected with the cannula through the side-port incision. Other staining techniques that use viscoelastic substances to increase the stability of the anterior chamber and to dose the injected dye have been described. The authors present an under-air staining technique of the anterior capsule using one drop of Trypan blue injected with a 30 G needle through the peripheral cornea. This procedure prevents the air bubble from escaping the anterior chamber and allows fast and selective staining of the capsule.Keywords: Trypan blue, staining technique, dye, cataract surgery, capsulorhexis

  15. Reduced anterior internal capsule white matter integrity in primary insomnia.

    Science.gov (United States)

    Spiegelhalder, Kai; Regen, Wolfram; Prem, Martin; Baglioni, Chiara; Nissen, Christoph; Feige, Bernd; Schnell, Susanne; Kiselev, Valerij G; Hennig, Jürgen; Riemann, Dieter

    2014-07-01

    Chronic insomnia is one of the most prevalent central nervous system diseases, however, its neurobiology is poorly understood. Up to now, nothing is known about the integrity of white matter tracts in insomnia patients. In this study, diffusion tensor imaging (DTI) was used in a well-characterized sample of primary insomnia (PI) patients and good sleeper controls to fill this void. Voxelwise between-group comparisons of fractional anisotropy (FA) were performed in 24 PI patients (10 males; 14 females; 42.7 ± 14.5 years) and 35 healthy good sleepers (15 males; 20 females; 40.1 ± 9.1 years) with age and sex as covariates. PI patients showed reduced FA values within the right anterior internal capsule and a trend for reduced FA values in the left anterior internal capsule. The results suggest that insomnia is associated with a reduced integrity of white matter tracts in the anterior internal capsule indicating that disturbed fronto-subcortical connectivity may be a cause or consequence of the disorder.

  16. Primary anterior chamber intraocular lens for the treatment of severe crystalline lens subluxation.

    Science.gov (United States)

    Hoffman, Richard S; Fine, I Howard; Packer, Mark

    2009-10-01

    Subluxated cataractous and clear lenses are commonly treated by limbal or pars plana lensectomy followed by primary or secondary intraocular lens (IOL) implantation. Adjunctive capsular prosthetic devices have facilitated lens removal and IOL centration in these challenging cases but have also added complexity and potential complications to the procedure. Although crystalline lens extraction may be required to clear the visual axis in mild to moderate lens subluxations, we propose insertion of a primary anterior chamber IOL without lens extraction in severe subluxations when the eye is optically aphakic or can be made functionally aphakic following neodymium:YAG laser zonulysis. Two cases demonstrating this approach are presented.

  17. Complications and visual outcomes after glued foldable intraocular lens implantation in eyes with inadequate capsules.

    Science.gov (United States)

    Kumar, Dhivya Ashok; Agarwal, Amar; Packiyalakshmi, Sathiya; Jacob, Soosan; Agarwal, Athiya

    2013-08-01

    To evaluate the complications and visual outcomes of glued intrascleral-fixated foldable intraocular lens (IOL) in eyes with deficient capsules. Dr Agarwal's Eye Hospital and Eye Research Centre, Chennai, India. Case series. Data were evaluated from the records of patients with a primary glued foldable IOL for intraoperative capsular loss or subluxated lens or secondary glued foldable IOL for aphakia. Exclusion criteria included preoperative glaucoma, aniridia, macular scar, traumatic subluxation, combined surgeries, incomplete operative medical records, and postoperative follow-up less than 6 months. The intraoperative and postoperative complication rates, reoperation rate, and visual outcomes were analyzed. The study comprised 208 eyes (185 patients). The mean follow-up was 16.7 months ± 10.2 (SD). The intraoperative complications were hyphema (0.4%), haptic breakage (0.4%), and deformed haptics (0.9%). Early complications occurred in 29 eyes (13.9%) and included corneal edema (5.7%), epithelial defect (1.9%), and grade 2 anterior chamber reaction (2.4%). Late complications occurred in 39 eyes (18.7%) and included optic capture (4.3%), IOL decentration (3.3%), haptic extrusion (1.9%), subconjunctival haptic (1.4%), macular edema (1.9%), and pigment dispersion (1.9%). Reoperation was required in 16 eyes (7.7%). Haptic position was altered in eyes with IOL decentration. Corrected distance visual acuity (CDVA) improved or remained unchanged in 84.6% of eyes. The postoperative CDVA was 20/40 or better and 20/60 or better in 38.9% and 48.5% of eyes, respectively. The foldable glued-IOL procedure showed satisfactory visual outcomes without serious complications. Intraocular lens decentration was due to haptic-related problems. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Tethered capsule OCT endomicroscopy for upper gastrointestinal tract imaging by using ball lens probe (Conference Presentation)

    Science.gov (United States)

    Dong, Jing; Gora, Michalina J.; Reddy, Rohith; Trasischker, Wolfgang; Poupart, Oriane; Lu, Weina; Carruth, Robert W.; Grant, Catriona N.; Soomro, Amna R.; Tiernan, Aubrey R.; Rosenberg, Mireille; Nishioka, Norman S.; Tearney, Guillermo J.

    2016-03-01

    While endoscopy is the most commonly used modality for diagnosing upper GI tract disease, this procedure usually requires patient sedation that increases cost and mandates its operation in specialized settings. In addition, endoscopy only visualizes tissue superfically at the macroscopic scale, which is problematic for many diseases that manifest below the surface at a microscopic scale. Our lab has previously developed technology termed tethered capsule OCT endomicroscopy (TCE) to overcome these diagnostic limitations of endoscopy. The TCE device is a swallowable capsule that contains optomechanical components that circumferentially scan the OCT beam inside the body as the pill traverses the organ via peristalsis. While we have successfully imaged ~100 patients with the TCE device, the optics of our current device have many elements and are complex, comprising a glass ferrule, optical fiber, glass spacer, GRIN lens and prism. As we scale up manufacturing of this device for clinical translation, we must decrease the cost and improve the manufacturability of the capsule's optical configuration. In this abstract, we report on the design and development of simplificed TCE optics that replace the GRIN lens-based configuration with an angle-polished ball lens design. The new optics include a single mode optical fiber, a glass spacer and an angle polished ball lens, that are all fusion spliced together. The ball lens capsule has resolutions that are comparable with those of our previous GRIN lens configuration (30µm (lateral) × 7 µm (axial)). Results in human subjects show that OCT-based TCE using the ball lens not only provides rapid, high quality microstructural images of upper GI tract, but also makes it possible to implement this technology inexpensively and on a larger scale.

  19. Anterior haptic flexing and in-the-bag subluxation of an accommodating intraocular lens due to excessive capsular bag contraction.

    Science.gov (United States)

    Kramer, Gregory D; Werner, Liliana; Neuhann, Tobias; Tetz, Manfred; Mamalis, Nick

    2015-09-01

    We describe the case of a patient who had cataract surgery with implantation of the hydrophilic acrylic Tetraflex accommodating intraocular lens (IOL), with subsequent development of capsulorhexis phimosis and in-the-bag IOL subluxation. Contraction of the capsular bag secondary to fibrosis resulted in significant anterior flexing of the lens haptic component. Explantation of the IOL-capsular bag complex was required 7 years after implantation. Histopathologic analysis demonstrated multiple areas of thick anterior subcapsular fibrosis. Pseudoexfoliative material was present throughout the surface of the lens capsule. Intraocular lenses manufactured from hydrophilic acrylic material are highly flexible and may be more susceptible to capsule contraction, even in the absence of predisposing ocular and systemic conditions. This case highlights the importance of developing guidelines regarding patient screening and selection for the appropriate use of accommodating and other highly flexible IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. [Posterior capsule opacification, capsular bag distension syndrome, and anterior capsular phimosis: A retrospective cohort study].

    Science.gov (United States)

    González-Martín-Moro, J; González-López, J J; Gómez-Sanz, F; Zarallo-Gallardo, J; Cobo-Soriano, R

    2015-02-01

    To determine the incidence and the risk factors involved in the development of the three main postoperative capsular complications: posterior capsule opacification (PCO), capsular bag distension syndrome (CBDS), and anterior capsular phimosis syndrome (ACP). A retrospective cohort study was conducted on 801 patients submitted to cataract surgery in the ophthalmology unit of Hospital del Henares (Madrid) from March 2, 2009 to February 28, 2010. Computerized clinical charts were reviewed during July 2012. PCO was studied using the Kaplan-Meier method (log rank test). A total of 167 patients developed PCO. No association could be demonstrated between PCO and age, sex, diabetes mellitus, phaco technique, IOL model, tamsulosin intake, glaucoma, and age-related macular degeneration. Three patients developed CBDS, all of them have received and Akreos Adapt AO(®) (Bausch & Lomb). Two of them were young men who had received surgery for posterior subcapsular cataracts. Three patients developed ACP, 2 of whom had received a MicroSlim(®) IOL (PhysIOL). No association was found between PCO and any of the studied variables. Male gender, young age, subcapsular cataract and large non-angulated lens such as Akreos Adapt AO(®) could be associated with CBDS. ACP could be more frequent when microincision IOLs (like MicroSlim(®)) are implanted. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  1. Leg and Femoral Neck Length Evaluation Using an Anterior Capsule Preservation Technique in Primary Direct Anterior Approach Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Stephen J Nelson

    2017-04-01

    Full Text Available Background Achieving correct leg and femoral neck lengths remains a challenge during total hip arthroplasty (THA.  Several methods for intraoperative evaluation and restoration of leg length have been proposed, and each has inaccuracies and shortcomings.  Both the supine positioning of a patient on the operating table during the direct anterior approach (DAA THA and the preservation of the anterior capsule tissue  are simple, readily available, and cost-effective strategies that can lend themselves well as potential solutions to this problem. Technique The joint replacement is performed through a longitudinal incision (capsulotomy of the anterior hip joint capsule, and release of the capsular insertion from the femoral intertrochanteric line. As trial components of the prosthesis are placed, the position of the released distal capsule in relationship to its original insertion line is an excellent guide to leg length gained, lost, or left unchanged. Methods The radiographs of 80 consecutive primary THAs were reviewed which utilized anterior capsule preservation and direct capsular measurement as a means of assessing change in leg/femoral neck length. Preoperatively, the operative legs were 2.81 +/- 8.5 mm (SD shorter than the nonoperative leg (range: 17.7 mm longer to 34.1 mm shorter.  Postoperatively, the operative legs were 1.05 +/- 5.64 mm (SD longer than the nonoperative leg (range: 14.9 mm longer to 13.7 mm shorter. Conclusion The preservation and re-assessment of the native anterior hip capsule in relationship to its point of release on the femur is a simple and effective means of determining leg/femoral neck length during DAA THA.

  2. [Capsule contraction as a cause of in-the-bag intraocular lens subluxation and simplified technique of IOL reposition].

    Science.gov (United States)

    Jurowski, Piotr

    2005-01-01

    Presentation of the case of the pseudophakic patient in whom 3 months after uncomplicated phacoemulsification severe capsule contraction syndrome, followed by equatorial capsule fibrosis, 240 degree zonular dialysis, and spontaneous in-the-bag intraocular lens subluxation, were observed. Consecutive surgical intervention consisting of simplified transscleral "free haptic" through the capsule fixation and additional plastic of phimotic capsulorrhexis allowed to restore the best corrected visual acuity to 20/25.

  3. Anterior joint capsule of the normal hip and in children with transient synovitis: US study with anatomic and histologic correlation

    NARCIS (Netherlands)

    S.G.F. Robben (Simon); M.H. Lequin (Maarten); A.F.M. Diepstraten (Ad); J.C. den Hollander (Jan); C.A. Entius; M. Meradji

    1999-01-01

    textabstractPURPOSE: To study the anatomic components of the anterior joint capsule of the normal hip and in children with transient synovitis. MATERIALS AND METHODS: Six cadaveric specimens were imaged with ultrasonography (US) with special attention to the anterior

  4. Intracapsular Lens Extraction for the Treatment of Pupillary Block Glaucoma Associated with Anterior Subluxation of the Crystalline Lens

    Directory of Open Access Journals (Sweden)

    Yong Joon Kim

    2013-11-01

    Full Text Available Purpose: To report a case of pupillary block glaucoma associated with spontaneous crystalline lens subluxation into the anterior chamber in a 34-year-old man. Methods: Dry vitrectomy was performed for securing enough retrolental space, and an intracapsular lens extraction was then performed via a corneolimbal incision. Additional endothelial cell damage was avoided with an injection of viscoelastics and gentle extraction of the crystalline lens. After deepening of the anterior chamber, scleral fixation of the intraocular lens was performed with an ab externo technique. Results: Two months after the operation, a well-fixated intraocular lens was observed and intraocular pressure was stable. The postoperative corneal astigmatism was -3.5 dpt, and the patient had a best-corrected visual acuity of 20/25. Postoperative complications included decreased endothelial cell count and sector iris paralysis near the incision site. Conclusions: An anteriorly subluxated crystalline lens can cause pupillary block glaucoma in healthy young adults. To prevent intraoperative complications, intracapsular lens extraction with dry vitrectomy can be a good surgical option. The endothelial cell density should be closely monitored after surgery.

  5. Intracapsular Lens Extraction for the Treatment of Pupillary Block Glaucoma Associated with Anterior Subluxation of the Crystalline Lens

    Science.gov (United States)

    Kim, Yong Joon; Ha, Seung Joo

    2013-01-01

    Purpose To report a case of pupillary block glaucoma associated with spontaneous crystalline lens subluxation into the anterior chamber in a 34-year-old man. Methods Dry vitrectomy was performed for securing enough retrolental space, and an intracapsular lens extraction was then performed via a corneolimbal incision. Additional endothelial cell damage was avoided with an injection of viscoelastics and gentle extraction of the crystalline lens. After deepening of the anterior chamber, scleral fixation of the intraocular lens was performed with an ab externo technique. Results Two months after the operation, a well-fixated intraocular lens was observed and intraocular pressure was stable. The postoperative corneal astigmatism was −3.5 dpt, and the patient had a best-corrected visual acuity of 20/25. Postoperative complications included decreased endothelial cell count and sector iris paralysis near the incision site. Conclusions An anteriorly subluxated crystalline lens can cause pupillary block glaucoma in healthy young adults. To prevent intraoperative complications, intracapsular lens extraction with dry vitrectomy can be a good surgical option. The endothelial cell density should be closely monitored after surgery. PMID:24348413

  6. Canine cataracts, diabetes mellitus and spontaneous lens capsule rupture: a retrospective study of 18 dogs.

    Science.gov (United States)

    Wilkie, D A; Gemensky-Metzler, A J; Colitz, C M H; Bras, I D; Kuonen, V J; Norris, K N; Basham, C R

    2006-01-01

    To describe the clinical presentation and surgical outcome of diabetic canine patients with cataracts and preoperative spontaneous lens capsule rupture. A total of 20 dogs and 40 eyes were included in the retrospective evaluation. The patients' ages ranged from 5 to 14 years (mean 8.5 years). All dogs had clinical diabetes mellitus, with the duration since diagnosis ranging from 30 to 240 days (mean 123 days). Cataracts were bilateral and noted to have been present for 14-112 days (mean 39 days). Of the 40 eyes affected with cataracts, 30 had a spontaneous rupture of the lens capsule prior to surgery. The capsular rupture was diagnosed on clinical examination in 28/30 eyes and was noted intraoperatively in 2/30. The location of the capsular rupture was equatorial in 29/30 and posterior in 1/30 eyes. Surgery was performed in 38/40 eyes, with one case lost to follow-up without surgical intervention. Prior to surgery, routine diagnostic ophthalmic examination, ocular ultrasound, electroretinography, and systemic evaluation were performed in all dogs. Surgical procedures included phacoemulsification in 28/40 eyes, with IOL placement performed in 20/28 eyes. Intrascleral prosthesis placement or enucleation was performed in 8/40 and 2/40 eyes, respectively, due to a significantly reduced ERG or secondary glaucoma. The duration of clinical follow-up (19/20 dogs) ranged from 1 to 36 months (mean 12.9 months). All eyes that had cataract surgery with or without IOL placement were sighted at the time of the last follow-up examination. Spontaneous lens capsule rupture associated with diabetes mellitus, cataract and rapid lens intumescence occurs in the dog. Early surgical intervention, prior to secondary complications of glaucoma and loss of retinal function, is associated with a favorable outcome.

  7. Lenticonus diagnosis in Alport's syndrome: Anterior capsule apical angle calculation using Scheimpflug imagery.

    Science.gov (United States)

    Jarrín, E; Jarrín, I; Arnalich-Montiel, F

    2015-08-01

    We describe a simplified method to detect anterior lenticonus. Three eyes of 2 patients with anterior lenticonus, plus 16 eyes from 16 healthy controls underwent Scheimpflug imaging of their anterior segment with Pentacam. The anterior capsule apex angle was manually identified and automatically measured by AutoCAD. The mean angle was 173.06° (SD: 1.91) in healthy subjects, and 158.33° (SD: 3.05) in anterior lenticonus eyes. The angle obtained from patients was more than 3 SD steeper than those from healthy subjects. The apical angle calculation method seems to discriminate well between normal eyes and eyes suspected of having anterior lenticonus. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  8. Stability of capsule closure and postoperative anterior knee pain after medial parapatellar approach in TKA.

    Science.gov (United States)

    Keshmiri, Armin; Dotzauer, Fabian; Baier, Clemens; Maderbacher, Günther; Grifka, Joachim; Sendtner, Ernst

    2017-07-01

    Anterior knee pain after total knee arthroplasty (TKA) remains a widely discussed postoperative complication. In contrast to sports traumatology, the role of the dissected medial patellofemoral ligament (MPFL) using a medial parapatellar approach in TKA has not been discussed so far. In the present study, it was hypothesized that the attempted repair of the MPFL in TKA by simple closure of the joint capsule may not be successful in some cases, causing anterior knee pain. Furthermore, it was hypothesized, that the success of repair might be influenced by femoral component rotation. Forty patients received their TKA in a ligament-balanced and forty patients in a conventional measured-resection technique. After implantation of the TKA using a medial parapatellar approach, two titan clips were attached on both sides of the capsule incision. 3 days and 3 months after surgery, the dehiscence of the two clips was measured on skyline patella radiographs; additionally patellar tilt, shift, the Knee Society Score and the Feller Score were obtained. 48 patients showed an increase of capsule dehiscence. Patients with a capsule dehiscence of more than 4 mm showed significantly less improvement in the Feller score 3 months postoperatively than patients with a capsule dehiscence ≤4 mm. Regarding the radiological measurements and the clinical outcome, no significant difference between the ligament-balanced and the measured-resection group was found. The present results suggest that the successful repair of the MPFL after using a medial parapatellar approach in TKA could reduce the high rate of postoperative anterior knee pain. Furthermore, the appearance of capsule dehiscence and anterior knee pain does not seem to be dependent on the used operative technique.

  9. Pathological findings in the lens capsules and intraocular lens in chronic pseudophakic endophthalmitis: an electron microscopy study.

    Science.gov (United States)

    Adán, A; Casaroli-Marano, R P; Gris, O; Navarro, R; Bitrian, E; Pelegrin, L; Sanchez-Dalmau, B

    2008-01-01

    The aim of this study was to describe the pathological findings in lens capsules and intraocular lens (IOL) studied by scanning and/or transmission electron microscopy (SEM and TEM, respectively) in a series of four eyes with chronic pseudophakic endophthalmitis (CPE). We performed a retrospective study of four patients presenting CPE in whom surgical treatment with pars plana vitrectomy, capsulectomy with extraction of the IOL, and intravitreous antibiotic therapy was thereafter performed. The extracted IOL and the capsular remains were studied by SEM and/or TEM and microbiologic analysis of aqueous humour and vitreous aspirate was also carried out in all the cases. The presence of microorganisms was observed in the material analysed in all the cases studied. The use of TEM identified bacterial contamination by Staphylococcus spp and mixed contamination with microorganisms presenting a bacillar morphology suggestive of infection by Propionibacterium acnes in addition to the presence of cocci in the capsular remains. In another two cases, SEM localized colonies of Staphylococcus spp on the surface of the IOL in one case and mixed bacterial colonization with cocci plus filamentous bacteria in the other. The presence of macrophages associated with bacteria was observed in the capsular remains. Microorganisms were found in the IOL or the capsular material in the four cases studied, thereby explaining the refractoriness and severity of infection. The possible presence of polymicrobial infections, especially in the cases with filamentous bacteria, also explains the recurrence of infection.

  10. Innervation of the Anterior Capsule of the Human Knee: Implications for Radiofrequency Ablation.

    Science.gov (United States)

    Franco, Carlo D; Buvanendran, Asokumar; Petersohn, Jeffrey D; Menzies, Robert D; Menzies, Linda Pham

    2015-01-01

    Chronic knee pain is common in all age groups. Some patients who fail conservative therapy benefit from radiofrequency neurotomy. Knowledge of the anatomy is critical to ensure a successful outcome. The purpose of this study was to reanalyze the innervation to the anterior knee capsule from the perspective of the interventional pain practitioner. The study included a comprehensive literature review followed by dissection of 8 human knees to identify the primary capsular innervation of the anterior knee joint. Photographs and measurements were obtained for each relevant nerve branch. Stainless-steel wires were placed along the course of each primary innervation, and radiographs were obtained. Literature review revealed a lack of consensus on the number and origin of nerve branches innervating the anterior knee capsule. All dissections revealed the following 6 nerves: superolateral branch from the vastus lateralis, superomedial branch from the vastus medialis, middle branch from the vastus intermedius, inferolateral (recurrent) branch from the common peroneal nerve, inferomedial branch from the saphenous nerve, and a lateral articular nerve branch from the common peroneal nerve. Nerve branches showed variable proximal trajectories but constant distal points of contact with femur and tibia. The inferolateral peroneal nerve branch was found to be too close to the common peroneal nerve, making it inappropriate for radiofrequency neurotomy. The innervation of the anterior capsule of the knee joint seems to follow a constant pattern making at least 3 of these nerves accessible to percutaneous ablation. To optimize clinical outcome, well-aligned radiographs are critical to guide lesion placement.

  11. Inner Synovial Membrane Footprint of the Anterior Elbow Capsule: An Arthroscopic Boundary

    Directory of Open Access Journals (Sweden)

    Srinath Kamineni

    2015-01-01

    Full Text Available Introduction. The purpose of this study is to describe the inner synovial membrane (SM of the anterior elbow capsule, both qualitatively and quantitatively. Materials and Methods. Twenty-two cadaveric human elbows were dissected and the distal humerus and SM attachments were digitized using a digitizer. The transepicondylar line (TEL was used as the primary descriptor of various landmarks. The distance between the medial epicondyle and medial SM edge, SM apex overlying the coronoid fossa, the central SM nadir, and the apex of the SM insertion overlying the radial fossa and distance from the lateral epicondyle to lateral SM edge along the TEL were measured and further analyzed. Gender and side-to-side statistical comparisons were calculated. Results. The mean age of the subjects was 80.4 years, with six male and five female cadavers. The SM had a distinctive double arched attachment overlying the radial and coronoid fossae. No gender-based or side-to-side quantitative differences were noted. In 18 out of 22 specimens (81.8%, an infolding extension of the SM was observed overlying the medial aspect of the trochlea. The SM did not coincide with the outer fibrous attachment in any specimen. Conclusion. The humeral footprint of the synovial membrane of the anterior elbow capsule is more complex and not as capacious as commonly understood from the current literature. The synovial membrane nadir between the two anterior fossae may help to explain and hence preempt technical difficulties, a reduction in working arthroscopic volume in inflammatory and posttraumatic pathologies. This knowledge should allow the surgeon to approach this aspect of the anterior elbow compartment space with the confidence that detachment of this synovial attachment, to create working space, does not equate to breaching the capsule. Alternatively, stripping the synovial attachment from the anterior humerus does not constitute an anterior capsular release.

  12. 25G posterior capsulotomy with anterior vitrectomy for posterior capsule opacification

    Directory of Open Access Journals (Sweden)

    Ying-Jie Lin

    2014-03-01

    Full Text Available AIM: To evaluate the efficacy and complications of 25G posterior capsulotomy with anterior vitrectomy for posterior capsule opacification(PCO. METHODS: The 25G transconjunctival sutureless vitrectomy technique was performed in 48 cases(68 eyesof PCO eyes. The mean follow-up was 24mo. Best-corrected visual acuity(BCVA, intraocular pressure, anterior chamber reaction and complications during and after the operation were observed. RESULTS: 4mm diameter round holes were obtained at the center of the posterior capsule in all eyes. At 1d postoperative, uncorrected visual acuity(UCVAwas 0.70±0.12(0.5-1.0, and BCVA was 0.73±0.10(0.6-1.0. At 3mo postoperative, UCVA was 0.72±0.12(0.5-1.0, and BCVA was 0.74±0.10(0.6-1.0. It was statistical significance between preoperative and postoperative UCVA(t=-45.902, P=0.000. There were no complications during the postoperative follow-up period, such as dislocation or damage of the IOL, corneal edema, endoophthalmitis, pupil vitreous hernia, vitreous prolapse, retina detachment, intraocular hypertension and reocclusion of the visual axis, etc.CONCLUSION: The 25G transconjunctival sutureless vitrectomy technique to remove PCO is a safe and effective procedure with less complications, which can be an alternative treatment for PCO.

  13. Evaluation of lens dose from anterior electron beams: comparison of Pinnacle and Gafchromic EBT3 film.

    Science.gov (United States)

    Sonier, Marcus; Wronski, Matt; Yeboah, Collins

    2015-03-08

    Lens dose is a concern during the treatment of facial lesions with anterior electron beams. Lead shielding is routinely employed to reduce lens dose and minimize late complications. The purpose of this work is twofold: 1) to measure dose pro-files under large-area lead shielding at the lens depth for clinical electron energies via film dosimetry; and 2) to assess the accuracy of the Pinnacle treatment planning system in calculating doses under lead shields. First, to simulate the clinical geometry, EBT3 film and 4 cm wide lead shields were incorporated into a Solid Water phantom. With the lead shield inside the phantom, the film was positioned at a depth of 0.7 cm below the lead, while a variable thickness of solid water, simulating bolus, was placed on top. This geometry was reproduced in Pinnacle to calculate dose profiles using the pencil beam electron algorithm. The measured and calculated dose profiles were normalized to the central-axis dose maximum in a homogeneous phantom with no lead shielding. The resulting measured profiles, functions of bolus thickness and incident electron energy, can be used to estimate the lens dose under various clinical scenarios. These profiles showed a minimum lead margin of 0.5 cm beyond the lens boundary is required to shield the lens to ≤ 10% of the dose maximum. Comparisons with Pinnacle showed a consistent overestimation of dose under the lead shield with discrepancies of ~ 25% occur-ring near the shield edge. This discrepancy was found to increase with electron energy and bolus thickness and decrease with distance from the lead edge. Thus, the Pinnacle electron algorithm is not recommended for estimating lens dose in this situation. The film measurements, however, allow for a reasonable estimate of lens dose from electron beams and for clinicians to assess the lead margin required to reduce the lens dose to an acceptable level.

  14. Effects of lens extirpation with anterior vitrectomy on vitreous three-dimensional mesh structure

    Directory of Open Access Journals (Sweden)

    Yan Zhao

    2017-06-01

    Full Text Available AIM: To investigate the changes in vitreous gel structure after lens extirpation combined with anterior vitrectomy in rabbit eyes. METHODS: Twenty-eight chinchilla rabbits were divided into three groups. The control group (Group I included 16 eyes from eight rabbits who did not receive any treatment. Group II included 20 eyes from 10 rabbits that underwent lens aspiration only. Group III included 20 eyes from 10 rabbits that underwent lens aspiration combined with posterior capsulotomy and anterior vitrectomy. Eyes were harvested on the 30th and 60th day postoperatively, respectively. Changes in vitreous gel stretch length due to gravity and the rate of vitreous liquefaction were observed. The collagen content in the vitreous body was examined using the L-hydroxyproline test. Electronic microscopic images were obtained from each eyeball. RESULTS: On both the 30th and 60th day postoperatively, the vitreous gel length of group III was significantly shorter than group I and group II (P<0.05, while the rate of liquefaction of the vitreous body in group III was significantly higher than group I and group II (P<0.05. The collagen content in group III was also higher than that in group I and group II (P<0.05. CONCLUSION: Loss of vitreous gel mass is more likely to occur in the eyes of rabbits receiving anterior vitrectomy. Lensectomy combined with anterior vitrectomy may damage the stable three-dimensional mesh structure of collagen, which could aggravate vitreous gel liquefaction.

  15. Clear lens phacoemulsification in the anterior lenticonus due to Alport Syndrome: two case reports.

    Science.gov (United States)

    Aslanzadeh, Ghassem Amir; Gharabaghi, Davoud; Naderi, Niloofar

    2008-05-27

    Alport Syndrome has a prevalence of 1 case per 5,000 people and 85% of patients have the X-linked form, where affected males develop renal failure and usually have high-tone sensorineural deafness by age 20. The main abnormality is deficient synthesis of type IV collagen, the main component of basement membranes. Common ocular abnormalities of this syndrome consist of dot-and-fleck retinopathy, posterior polymorphous corneal dystrophy, and anterior lenticonus, but other ocular defects such as cataracts, posterior lenticonus, and retinal detachments have also been reported. We report two cases of anterior lenticonus due to Alport Syndrome and describe clear lens phacoemulsification and foldable intraocular lens implantation as an effective and safe refractive procedure in the four eyes of these two patients. All four eyes of the two patients were in good condition after surgery and achieved satisfactory optical and visual results and had no remarkable complications at six-months follow-up. Clear lens phacoemulsification with foldable intraocular lens implantation can be used as an efficient and safe procedure for vision disorders in these patients.

  16. Clear lens phacoemulsification in the anterior lenticonus due to Alport Syndrome: two case reports

    Directory of Open Access Journals (Sweden)

    Aslanzadeh Ghassem

    2008-05-01

    Full Text Available Abstract Introduction Alport Syndrome has a prevalence of 1 case per 5,000 people and 85% of patients have the X-linked form, where affected males develop renal failure and usually have high-tone sensorineural deafness by age 20. The main abnormality is deficient synthesis of type IV collagen, the main component of basement membranes. Common ocular abnormalities of this syndrome consist of dot-and-fleck retinopathy, posterior polymorphous corneal dystrophy, and anterior lenticonus, but other ocular defects such as cataracts, posterior lenticonus, and retinal detachments have also been reported. Case presentation We report two cases of anterior lenticonus due to Alport Syndrome and describe clear lens phacoemulsification and foldable intraocular lens implantation as an effective and safe refractive procedure in the four eyes of these two patients. Conclusion All four eyes of the two patients were in good condition after surgery and achieved satisfactory optical and visual results and had no remarkable complications at six-months follow-up. Clear lens phacoemulsification with foldable intraocular lens implantation can be used as an efficient and safe procedure for vision disorders in these patients.

  17. Pure dysarthria due to anterior internal capsule and/or corona radiata infarction: a report of five cases.

    Science.gov (United States)

    Ozaki, I; Baba, M; Narita, S; Matsunaga, M; Takebe, K

    1986-01-01

    Five cases with a sudden onset of dysarthria in the setting of hypertension are presented. No case had limb weakness or other neurological deficits. Computed tomographic scan demonstrated a small low density lesion in the anterior part of the internal capsule or the adjacent corona radiata. All cases showed a good recovery from dysarthria within two to four weeks. Images PMID:3806121

  18. Surgical Management of a Patient with Anterior Megalophthalmos, Lens Subluxation, and a High Risk of Retinal Detachment

    Directory of Open Access Journals (Sweden)

    María Carmen Guixeres Esteve

    2017-01-01

    Full Text Available The early development of lens opacities and lens subluxation are the most common causes of vision loss in patients with anterior megalophthalmos (AM. Cataract surgery in such patients is challenging, however, because of anatomical abnormalities. Intraocular lens dislocation is the most common postoperative complication. Patients with AM also seem to be affected by a type of vitreoretinopathy that predisposes them to retinal detachment. We here present the case of a 36-year-old man with bilateral AM misdiagnosed as simple megalocornea. He had a history of amaurosis in the right eye due to retinal detachment. He presented with vision loss in the left eye due to lens subluxation. Following the removal of the subluxated lens, it was deemed necessary to perform a vitrectomy in order to prevent retinal detachment. Seven months after surgery, an Artisan® Aphakia iris-claw lens was implanted in the anterior chamber. Fifteen months of follow-up data are provided.

  19. Anterior and posterior capsule densitometry levels after femtosecond laser-assisted cataract surgery

    Directory of Open Access Journals (Sweden)

    Txomin Alberdi

    2018-04-01

    Full Text Available AIM: To analyze and compare five different variables over one year follow-up (1wk, 1, 3, 6 and 12mo: anterior capsule (AC, and posterior capsule (PC area densitometry values, AC and PC linear densitometry values, and AC opening area reduction ratio after femtosecond laser-assisted cataract surgery. METHODS: This was a prospective comparative study. Seventy-one patients underwent femtosecond laser-assisted cataract surgery on single eye between June 2014 and December 2015. A 5.0 mm diameter laser assisted anterior capsulotomy was performed on all eyes. In every post-surgery evaluation, AC opacificaction (ACO and PC opacification (PCO density levels were provided by Oculus Pentacam®HR using area and linear densitometry methods. Digital images were captured with a slit-lamp Topcon photographic camera and IMAGEnet® 5 software. The AC opening area on the digital images was measured using the Sketchandcalc area calculator and converted to reduction ratio levels. RESULTS: Using Pearson correlation coefficient (PCC, we found no correlation (r=-0.091, P=0.46 in the twelfth month assessment between the evolution of ACO area densitometry values and PCO area densitometry values considered as independent variables. We found no correlation, using PCC (r=-0.096, P=0.43 between the evolution of ACO linear densitometry values and PCO linear densitometry values, in the twelfth month visit, working both as independent variables. AC linear densitometry levels and AC area densitometry levels continued to grow strongly from sixth to twelfth months. Analysis of the values of AC opening area reduction ratio (1wk, 1, 3, 6, 12mo revealed statistically significant differences between the values of successive examinations but the magnitude of the change decreased. In the final period of monitoring between six and twelve months the magnitude of change was low. CONCLUSION: Our results show strong increases of Scheimpflug ACO densitometry values from the sixth to the

  20. The effect of Nd:YAG laser treatment of posterior capsule opacification on anterior chamber depth and refraction in pseudophakic eyes

    Directory of Open Access Journals (Sweden)

    Khambhiphant B

    2015-03-01

    Full Text Available Bharkbhum Khambhiphant,1 Chayata Liumsirijarern,2 Piyada Saehout1 1Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, 2Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand Purpose: This was a prospective descriptive study to determine the changes in intraocular lens (IOL position after neodymium-doped yttrium–aluminum–garnet (Nd:YAG laser posterior capsulotomy by measuring anterior chamber depth (ACD and refraction, including the spherical equivalent (SE and cylinder. Materials and methods: Forty-seven pseudophakic eyes with posterior capsule opacification of 29 patients were included. Nd:YAG laser posterior capsulotomy was performed. Patients’ ACD and refraction were measured before the treatment, as well as after the treatment at 1 week and 3 months. IOLMaster® and an automated refractometer were used at the Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand. Results: There were no statistically significant differences in ACD and SE before and after laser treatment at 1 week and 3 months (repeated analysis of variance, P=0.582 and P=0.269, respectively. Both backward IOL movement (number [n]=29 and forward IOL movement (n=18 were found. Some changes in cylindrical refraction were found at 1 week, but decreased at 3 months after capsulotomy (baseline cylinder: -1.16; cylinder at 1 week and 3 months: -1.00 and -1.14, respectively; P=0.012. These changes were the same with one-piece and three-piece IOLs. Conclusion: Nd:YAG laser posterior capsulotomy did not significantly change ACD and SE. It led to cylinder change at 1 week after laser, but the effect decreased at 3 months. This effect was small and may not be clinically significant. Keywords: posterior capsule opacification, neodymium-doped yttrium–aluminum–garnet, anterior chamber depth, pseudophakia, refraction

  1. Ultrastructural effects of silicone oil on the clear crystalline lens of the human eye.

    Science.gov (United States)

    Soliman, Wael; Sharaf, Mohamed; Abdelazeem, Khaled; El-Gamal, Dalia; Nafady, Allam

    2018-03-01

    To evaluate light and electron microscopic changes of the anterior capsule and its epithelium after clear lens extraction of vitrectomized myopic eyes with silicone oil tamponade. This prospective, controlled, non-randomized, interventional study included 20 anterior lens capsular specimens that were excised during combined clear lens extraction and silicone oil removal from previously vitrectomized highly myopic patients with silicone oil tamponade for previous retinal detachment surgeries. The specimens were examined via light microscopy and electron microscopy and compared with 20 anterior capsule specimens removed during clear lens extraction of non-vitrectomized highly myopic eyes. Light microscopic examination of clear lens anterior capsule specimens of vitrectomized myopic eyes filled with silicone oil showed relatively more flat cells with irregular outline of lens' epithelial cells with wide intercellular spaces, deeply stained nuclei, and multiple intracytoplasmic vacuoles. Scanning electron microscopy revealed collagenous surfaces filled with multiple pits, depressions, and abnormal deposits. Transmission electron microscopy revealed lens epithelial cells with apoptotic changes, many cytoplasmic vacuoles, and filopodia-like protrusions between lens epithelial cells and the capsule. Epithelial proliferation and multilayering were also observed. silicone oil may play a role in the development of apoptotic and histopathological changes in clear lens epithelial cells. Clarity of the lens at the time of silicone oil removal does not indicate an absence of cataractous changes. We found justification of combined clear lens extraction and silicone oil removal or combined phacovitrectomy when silicone oil injection is planned, but further long-term studies with larger patient groups are required.

  2. Preoperative anterior segment optical coherence tomography as a predictor of postoperative phakic intraocular lens position.

    Science.gov (United States)

    Fallah Tafti, Mohammad Reza; Moghadam, Reza Soltani; Beheshtnejad, Amir Houshang; Jabbarvand, Mahmoud; Mohebi, Masoomeh; Zarei-Ghanavati, Mehran

    2013-12-01

    To evaluate anterior segment optical coherence tomography (AS-OCT) in the preoperative simulation of postoperative iris-fixated phakic intraocular lens (pIOL) position in the anterior chamber. Farabi Eye Research Center, Department of Ophthalmology, Tehran University of Medical Sciences, Tehran, Iran. Case series. Using AS-OCT, the pIOL position was simulated preoperatively in 2 ways and compared with the actual postoperative pIOL position. For preoperative evaluations, the simulator was placed on the posterior pigmented epithelium of the iris. Then, the simulation was performed with the simulator placed in the middle of the iris tissue. The following distances were measured: from the center of the pIOL to the endothelium, from the edge of the pIOL to the endothelium, and from the posterior surface of the pIOL to the crystalline lens. The study examined 26 eyes (16 patients). Although all distances in both simulation methods (except the lens vault in the first method of simulation) were highly correlated (all P<.009), only the results with the simulator placed in the middle of the iris tissue were not statistically different from the corresponding postoperative measurements (P=.209 and P=.564 for distance from endothelium to the center and the pIOL edge, respectively). Using the pIOL template of the AS-OCT system for preoperative simulation of iris-fixated pIOLs improved the criteria for patient selection for implantation of these pIOLs. The simulator should be placed in the middle of the iris tissue for preoperative simulation. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Relation of the radial nerve to the anterior capsule of the elbow: anatomy with correlation to arthroscopy.

    Science.gov (United States)

    Omid, Reza; Hamid, Nady; Keener, Jay D; Galatz, Leesa M; Yamaguchi, Ken

    2012-12-01

    To determine the location and proximity of the radial nerve to the anterior capsule and to delineate and describe the anatomy of the brachialis as it relates to the radial nerve and anterior capsule. Arthroscopy was performed on 24 cadavers using only a standard anteromedial portal. A Beath pin was placed laterally, entering the joint at the most lateral edge of the radiocapitellar joint space, and a suture was placed through the pin and into the joint for reference during the dissection. The second phase was to perform open anatomic dissections. We found that in all specimens the radial nerve coursed longitudinally medial to the capitellum. The brachialis muscle was found to lie between the radial nerve and the joint capsule at the joint line and all proximal levels. Only at the most distal aspect of the joint line (corresponding to the level of the radial neck) did the nerve run in direct contact with the capsule in 11 specimens (55%). The brachialis muscle thickness was 4 mm or greater at the joint line and at all proximal measurement points. We found that the radial nerve is more medially located than previously thought. At the level of the radiocapitellar joint line, the radial nerve runs medial to the capitellum. The brachialis muscle lies between the radial nerve and the joint capsule at the level of the joint line and proximally. Arthroscopic capsular release laterally should be performed at the level of the joint line or above. The most dangerous area for capsular resection is distally over the radial head/neck, where 50% of our specimens had no brachialis protecting the nerve. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  4. Influence of anterior chamber depth, anterior chamber volume, axial length, and lens density on postoperative endothelial cell loss.

    Science.gov (United States)

    Reuschel, Anna; Bogatsch, Holger; Oertel, Nicole; Wiedemann, Renate

    2015-05-01

    To evaluate the influence of anterior chamber depth (ACD), anterior chamber volume (ACV), lens density (LD), and axial length (AL) as risk factors on endothelial cell loss 3 months after cataract surgery. We enrolled 47 patients with senile cataract who were operated between July 2012 and March 2013 by the same surgeon using torsional phacoemulsification. Preoperatively, we measured ACD, ACV, and LD using the Oculus Pentacam®. The AL was determined using the IOL Master®. Primary outcomes were central endothelial density (ECD) and corrected distance visual acuity (CDVA) 3 months after surgery We evaluated the effect of ACD, ACV, LD, and AL as possible risk factors of postoperative percentage endothelial cell loss (ECL). The median age was 72 years. The median CDVA before surgery was 0.5 improving to 1.0 postoperatively. The median ECL was 5.2 % (range 1.7 %-7.6 %). These results are comparable to our previous study (median ECL 6.9 % after 3 months) [Reuschel et al. (2010) J Cataract Refract Surg]. The median ACD in our study was 2.56 mm (range 2.26 mm-2.8 mm). Median ACV was 144 mm(3) (range 121 mm(3)-158 mm(3)]. The median LD was 12.4 (range 11.4-13.7). Median AL was 23.1 mm (range 22.7 mm-23.9 mm). Our correlation analysis showed no significant correlation between ACD, ACV, LD, AL, and postoperative ECL. ACD, ACV, AL, and LD were not identified as risk factors of postoperative endothelial cell loss in our analysis.

  5. Conjunctival lymphoma: Results and treatment with a single anterior electron field. A lens sparing approach

    International Nuclear Information System (INIS)

    Dunbar, S.F.; Linggood, R.M.; Doppke, K.P.; Duby, A.; Wang, C.C.

    1990-01-01

    Lymphoma of the conjunctiva is rare. It presents in older patients as a mass lesion and usually remains localized. Surgery is limited to biopsy, and radiation therapy is the definitive treatment of choice. The entire conjunctiva is treated. Relatively high doses (approximately 30 Gy) are required for local control, which may lead to cataract formation. Twelve patients with conjunctival lymphoma were treated at the Massachusetts General Hospital between 1979 and 1988. Ten of 12 patients presented with a unilateral lesion; 2 of 12 with bilateral lesions. Two of 12 patients were found to have systemic disease at the time of presentation. One patient developed conjunctival lymphoma 5 years after the diagnosis of generalized disease. Using electron beam, all patients were treated with a single anterior circular field to total doses ranging from 24 Gy to 30 Gy delivered in 8 to 16 fractions over 9 to 20 days. In all cases, the lens was shielded by a specially designed plastic contact lens bearing a 12 mm diameter lead shield. The lens dose was determined at varying depths beneath the shield for 6 MeV and 9 MeV electron beams and ranged from a minimum of 5% to an absolute maximum of 18% of the total dose delivered to the tumor. Local control was maintained in all patients with follow-up to 9 1/2 years. One patient relapsed distantly 3 years after treatment. One of 12 patients died of systemic disease 4 years after treatment of the ocular lesion. Two patients developed cataracts 4 and 5 years after treatment; one had bilateral cataract, although only one eye had been treated. Both patients were over 75 years old. In both cases, the cataracts were felt to be senile cataracts which are ophthalmologically and radiographically distinguishable from radiation induced lesions

  6. Spontaneous dislocation of lens bag with acrylic lens after uneventful cataract surgery ? unusual complication of cataract surgery

    OpenAIRE

    Shah, Mehul A.; Shah, Shreya M.; Mehta, Ruchir; Shah, Prerna

    2015-01-01

    Introduction: Spontaneous dislocation of intraocular lens with bag is rare.Methods: We report a case of a 56-year-old male who presented with spontaneous anterior dislocation of an in-the-bag intraocular lens 3 years after manual small incision cataract surgery. He had undergone manual small incision cataract surgery with foldable acrylic intraocular lens implantation, and 18 months after cataract surgery ND: YAG capsulotomy with uneventful post capsulotomy follow-up. 17 months after capsul...

  7. A safe technique for in-the-bag intraocular lens implantation in pediatric cataract surgery.

    Science.gov (United States)

    Khokhar, Sudarshan; Sharma, Reetika; Patil, Bharat; Sinha, Gautam; Nayak, Bhagabat; Kinkhabwala, Ravish Akhilkumar

    2015-01-01

    To describe a safe technique for in-the-bag intraocular lens (IOL) implantation in pediatric cataract patients who undergo lens aspiration with primary posterior capsulorhexis and anterior vitrectomy. Sixty eyes of 45 consecutive patients with congenital/developmental cataract underwent lens aspiration with primary posterior continuous curvilinear capsulorhexis (PCCC) with anterior vitrectomy and in-the-bag IOL implantation using the described technique of IOL implantation using anterior capsule as support. All eyes had stable IOL at the end of surgery and none of the eyes had lens decentration/dislocation in posterior vitreous. Implantation of in-the-bag IOL is difficult in children who undergo primary PCCC with anterior vitrectomy. Our technique of implanting IOL by pushing it against the back surface of anterior capsule is a safe method and results in no complications related to faulty IOL implantation.

  8. Vitrectorhexis and lens aspiration with posterior chamber intraocular lens implantation in spherophakia.

    Science.gov (United States)

    Al-Haddad, Christiane; Khatib, Lama

    2012-07-01

    We describe a technique that uses the vitrector to perform successful lens aspiration and posterior chamber intraocular lens (IOL) implantation in children with spherophakia and anterior lens subluxation. After an anterior chamber maintainer is placed, the ocutome is introduced through a limbal incision to perform a circular vitrectorhexis to avoid excessive manipulation of the unstable lens followed by gentle cortex aspiration. A foldable IOL is injected into the sulcus (3-piece IOL) or bag (1-piece IOL) if the capsule is sufficiently stable. Through a pars plana incision, the ocutome is then used to perform a posterior capsulotomy to prevent late posterior capsule opacification. In our patient, sulcus IOL placement was more stable than in-the-bag placement. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Spontaneous bilateral anterior partial in-the-bag intraocular lens dislocation following routine annual eye examination.

    Science.gov (United States)

    Ford, Joshua R; Werner, Liliana; Owen, Leah; Vasavada, Shail A; Crandall, Alan

    2014-09-01

    We present the case of an 81-year-old man with pseudoexfoliation syndrome (PXF) in whom spontaneous bilateral anterior partial in-the-bag intraocular lens (IOL) dislocation was diagnosed following a routine dilated examination that demonstrated only mild pseudophacodonesis with no evidence of subluxation. Uneventful cataract surgery with placement of single-piece hydrophobic acrylic posterior chamber IOLs had been performed in both eyes 7 years previously. Bilateral IOL repositioning with scleral fixation was performed to correct the dislocation. Postoperative examinations showed remarkable improvement in visual acuity and IOL stability. We hypothesize that zonular weakness secondary to PXF predisposed the patient to bilateral IOL partial dislocation. Pupil dilation in the setting of mild pseudophacodonesis at the time of routine examination may have been a precipitating factor. To our knowledge, bilateral IOL subluxation/dislocation has been described in a limited number of case reports. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Cx43, ZO-1, alpha-catenin and beta-catenin in cataractous lens

    Indian Academy of Sciences (India)

    Specimens of the anterior lens capsule with an attached monolayer of lens epithelial cells (LECs) were obtained from patients (=52) undergoing cataract surgery. Specimens were divided into three groups based on the type of cataract: nuclear cataract, cortical cataract and posterior subcapsular cataract (PSC).

  11. Cx43, ZO-1, alpha-catenin and beta-catenin in cataractous lens ...

    Indian Academy of Sciences (India)

    Specimens of the anterior lens capsule with an attached monolayer of lens epithelial cells (LECs) were obtained from patients (=52) undergoing cataract surgery. Specimens were divided into three groups based on the type of cataract: nuclear cataract, cortical cataract and posterior subcapsular cataract (PSC).

  12. Lens regeneration in juvenile and adult rabbits measured by image analysis.

    Science.gov (United States)

    Gwon, A E; Jones, R L; Gruber, L J; Mantras, C

    1992-06-01

    Secondary cataract growth commonly occurs after extracapsular cataract extraction. The proliferation of this regrowth occurs at rates related to many factors. In this study, the authors analyzed the amount of lens regeneration after endocapsular lens extraction that leaves the anterior and posterior capsules relatively intact. The analysis was performed in New Zealand albino rabbits with the aid of image analysis measurements in young and adult animals. The effect of low vacuum suction of the anterior capsule on the growth was determined. Lens regeneration was used as a measure of the growth potential of the leftover epithelial cells in the capsule bag. The results showed that lens regeneration was significantly faster in younger rabbits. However, low vacuum suction had no effect on the growth rate. Potential therapeutic agents for preventing secondary cataracts may be better analyzed with image analysis processing of lens regeneration, a precise and rapid measurement technique.

  13. Randomized Controlled Trial for Efficacy of Capsular Distension for Adhesive Capsulitis: Fluoroscopy-Guided Anterior Versus Ultrasonography-Guided Posterolateral Approach

    OpenAIRE

    Bae, Jae Hyun; Park, Young Sook; Chang, Hyun Jung; Kim, Min Jung; Park, Kang Young; Jin, Seung Hwan; Lee, Eun Hee

    2014-01-01

    Objective To find the most effective procedure to treat adhesive capsulitis of the shoulder, we evaluated the clinical effects of an ultrasonographic-guided anterior approach capsular distension and a fluoroscopy-guided posterolateral approach capsular distension. We expected the anterior approach to be better than the posterolateral approach because the rotator interval, a triangular anatomic area in the anterosuperior aspect of the shoulder, which is considered an important component of the...

  14. Effect of myopic adolescents wearing orthokeratology lens on the corneal surface curvature radius and anterior chamber depth

    Directory of Open Access Journals (Sweden)

    Qian Yu

    2017-06-01

    Full Text Available AIM: To analyze the effect of myopic adolescents wearing orthokeratology lens on the corneal surface curvature radius and anterior chamber depth. METHODS: Totally 120 cases of adolescent myopia were selected, among them 58 cases with 116 eyes were divided into 11-14 years old group and 62 cases with 124 eyes were 15-18 years old group according to the age. They were treated with long-term orthokeratology lens treatment, and two groups of patients were observed before wearing lens(T0, wearing for 6mo(T1, 12mo(T2for uncorrected visual acuity, the average refractive degree improvement, the central corneal thickness, corneal curvature changes and the incidence of complications. RESULTS: The uncorrected visual acuity of the two groups at 12mo after wearing were better than that at 6mo which was better than that before wearing; the diopter had the same trend. The uncorrected visual acuity and the diopter of the 11-14 years old group at 6 and 12mo was better than those of 15-18 years old group with significant difference(PP>0.05. The corneal anterior surface curvature of the two groups at 12mo after wearing were more than that at 6mo which was more than that before wearing. The axial length of the 11-14 years old group was longer than that of the 15-18 years old group with significant difference(PP>0.05. There was no significant difference on the anterior chamber depth between the two groups at different time or between before and after wearing(P>0.05.CONCLUSION: Long-term wearing orthokeratology lenses have a significant effect for control ling juvenile myopia, and can improve the corneal anterior surface curvature, especially in the lower age group, and has no significant effect on the anterior chamber depth.

  15. Cultivation and characterization of cornea limbal epithelial stem cells on lens capsule in animal material-free medium.

    Directory of Open Access Journals (Sweden)

    Réka Albert

    Full Text Available A simple, reproducible, animal-material free method for cultivating and characterizing cornea limbal epithelial stem cells (LESCs on human lens capsule (LC was developed for future clinical transplantation. The limbal tissue explants (2 × 2 × 0.25 mm were harvested from 77 cadavers and expanded ex vivo on either cell culture plates or LC in medium containing human serum as the only growth supplement. Cell outgrowth at the edge of the explants was observed within 24 hours of cultivation and achieved viable outgrowth (>97% viability as measured by MTT assay and flow cytometry within two weeks. The outgrowing cells were examined by genome-wide microarray including markers of stemness (p63α, ABCG2, CK19, Vimentin and Integrin α9, proliferation (Ki-67, limbal epithelial cells (CK 8/18 and 14 and differentiated cornea epithelial cells (CK 3 and 12. Immunostaining revealed the non-hematopoietic, -endothelial and -mesenchymal stem cell phenotype of the LESCs and the localization of specific markers in situ. Cell adhesion molecules, integrins and lectin-based surface carbohydrate profiling showed a specific pattern on these cells, while colony-formation assay confirmed their clonal potency. The LESCs expressed a specific surface marker fingerprint (CD117/c-kit, CXCR4, CD144/VE-Cadherin, CD146/MCAM, CD166/ALCAM, and surface carbohydrates: WGA, ConA, RCA, PNA and AIL which can be used for better localization of the limbal stem cell niche. In summary, we report a novel method combining the use of a medium with human serum as the only growth supplement with LC for cultivating, characterizing and expanding cornea LESCs from cadavers or alternatively from autologous donors for possible treatment of LESC deficiency.

  16. Cultivation and characterization of cornea limbal epithelial stem cells on lens capsule in animal material-free medium.

    Science.gov (United States)

    Albert, Réka; Veréb, Zoltán; Csomós, Krisztián; Moe, Morten C; Johnsen, Erik O; Olstad, Ole Kristoffer; Nicolaissen, Bjørn; Rajnavölgyi, Eva; Fésüs, László; Berta, András; Petrovski, Goran

    2012-01-01

    A simple, reproducible, animal-material free method for cultivating and characterizing cornea limbal epithelial stem cells (LESCs) on human lens capsule (LC) was developed for future clinical transplantation. The limbal tissue explants (2 × 2 × 0.25 mm) were harvested from 77 cadavers and expanded ex vivo on either cell culture plates or LC in medium containing human serum as the only growth supplement. Cell outgrowth at the edge of the explants was observed within 24 hours of cultivation and achieved viable outgrowth (>97% viability as measured by MTT assay and flow cytometry) within two weeks. The outgrowing cells were examined by genome-wide microarray including markers of stemness (p63α, ABCG2, CK19, Vimentin and Integrin α9), proliferation (Ki-67), limbal epithelial cells (CK 8/18 and 14) and differentiated cornea epithelial cells (CK 3 and 12). Immunostaining revealed the non-hematopoietic, -endothelial and -mesenchymal stem cell phenotype of the LESCs and the localization of specific markers in situ. Cell adhesion molecules, integrins and lectin-based surface carbohydrate profiling showed a specific pattern on these cells, while colony-formation assay confirmed their clonal potency. The LESCs expressed a specific surface marker fingerprint (CD117/c-kit, CXCR4, CD144/VE-Cadherin, CD146/MCAM, CD166/ALCAM, and surface carbohydrates: WGA, ConA, RCA, PNA and AIL) which can be used for better localization of the limbal stem cell niche. In summary, we report a novel method combining the use of a medium with human serum as the only growth supplement with LC for cultivating, characterizing and expanding cornea LESCs from cadavers or alternatively from autologous donors for possible treatment of LESC deficiency.

  17. Anterior capsule staining using 0.025% trypan blue in cataracts without red reflex Uso de azul tripano a 0,025% para corar a cápsula anterior em catarata sem reflexo

    Directory of Open Access Journals (Sweden)

    Eduardo Ferrari Marback

    2001-08-01

    Full Text Available Purpose: To describe the use of anterior capsule staining in cataracts without red reflex using a 0.025% trypan blue solution. Methods: Six eyes of 6 patients with cataracts without red reflex were submitted to phacoemulsification using a direct injection of 0.2 to 0.5 ml of 0.025% trypan blue in the anterior chamber previous to viscoelastic injection. All patients had an ophthalmologic examination prior to surgery, as well as pre and postoperative corneal endothelial cell count. Results: In all cases the capsule became stained with a faint blue color that enabled an adequate visibility of the flap during the continuous curvilinear anterior capsulotomy (CCC. There were no intra-or postoperative complications. The endothelial cell loss varied between 1.8% and 26.6% (mean 12.8%. Conclusion: Staining the anterior capsule with 0.025% trypan blue solution allows a good visibility of the capsular flap and facilitates the confection of CCC in cataracts without red reflex.

  18. Small-incision 4-point scleral suture fixation of a foldable hydrophilic acrylic intraocular lens in the absence of capsule support.

    Science.gov (United States)

    Terveen, Daniel C; Fram, Nicole R; Ayres, Brandon; Berdahl, John P

    2016-02-01

    To determine the visual outcomes and complications of a new small-incision technique for 4-point fixation of a hydrophilic acrylic posterior chamber intraocular lens (IOL) in the absence of capsule support. Three North American tertiary referral centers and a private practice. Retrospective case series. Secondary IOL placement was performed from 2011 to 2014. Indications for surgery, clinical results, and complications were analyzed. Primary outcomes included postoperative corrected distance visual acuity (CDVA) and surgical complications. Charts of 35 patients (37 eyes) were reviewed. The mean age at surgery was 56 years, and the mean follow-up was 6 months (range 3 to 24 months). Clinical indications included a dislocated IOL (30%), ocular trauma (19%), crystalline lens subluxation (19%), uveitis-glaucoma-hyphema syndrome (5%), post-complicated cataract (8%), congenital cataract (8%), and decompensated cornea (3%). The mean CDVA improved from 20/80 preoperatively to 20/40 postoperatively (P IOL dislocation (3%). Small-incision 4-point scleral fixation of the Akreos AO60 hydrophilic acrylic IOL in the absence of capsule support appears to be a safe and effective technique for secondary IOL placement. Drs. Berdahl and Ayres are consultants to Bausch & Lomb, Inc. Drs. Ayres and Fram have received speaker fees from Bausch & Lomb. Dr. Terveen does not have a financial or proprietary interest in any material or methods mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Microplasma Induced Cell Morphological Changes and Apoptosis of Ex Vivo Cultured Human Anterior Lens Epithelial Cells - Relevance to Capsular Opacification.

    Directory of Open Access Journals (Sweden)

    Nina Recek

    Full Text Available Inducing selective or targeted cell apoptosis without affecting large number of neighbouring cells remains a challenge. A plausible method for treatment of posterior capsular opacification (PCO due to remaining lens epithelial cells (LECs by reactive chemistry induced by localized single electrode microplasma discharge at top of a needle-like glass electrode with spot size ~3 μm is hereby presented. The focused and highly-localized atmospheric pressure microplasma jet with electrode discharge could induce a dose-dependent apoptosis in selected and targeted individual LECs, which could be confirmed by real-time monitoring of the morphological and structural changes at cellular level. Direct cell treatment with microplasma inside the medium appeared more effective in inducing apoptosis (caspase 8 positivity and DNA fragmentation at a highly targeted cell level compared to treatment on top of the medium (indirect treatment. Our results show that single cell specific micropipette plasma can be used to selectively induce demise in LECs which remain in the capsular bag after cataract surgery and thus prevent their migration (CXCR4 positivity to the posterior lens capsule and PCO formation.

  20. PARS PLANA VITRECTOMY WITH ANTERIOR CHAMBER VERSUS GORE-TEX SUTURED POSTERIOR CHAMBER INTRAOCULAR LENS PLACEMENT: LONG-TERM OUTCOMES.

    Science.gov (United States)

    Khan, M Ali; Gupta, Omesh P; Pendi, Kasim; Chiang, Allen; Vander, James; Regillo, Carl D; Hsu, Jason

    2018-01-16

    To compare clinical outcomes of combined pars plana vitrectomy (PPV) with anterior chamber intraocular lens (ACIOL) placement versus scleral fixation of a posterior chamber intraocular lens (PCIOL) using Gore-Tex suture. Retrospective, interventional case series of eyes undergoing combined PPV and IOL placement for retained lens material, aphakia, or dislocated IOL. Eyes with history of amblyopia, corneal opacity, retinal, or optic nerve disease were excluded. Outcome measures were change in visual acuity and occurrence of postoperative complications with minimum follow-up of 1 year. Sixty-three eyes of 60 patients were identified. Thirty-three eyes underwent combined PPV and ACIOL placement and 30 eyes underwent combined PPV and scleral fixation of a PCIOL using Gore-Tex suture. Mean follow-up was 502 ± 165 days (median 450, range 365-1,095 days). In the ACIOL group, mean visual acuity improved from 20/914 preoperatively to 20/50 postoperatively (P Gore-Tex suture were well tolerated. The techniques resulted in similar visual outcomes at minimum follow-up of 1 year.

  1. Pars Plana Vitrectomy in Treatment of Lens Injury

    Directory of Open Access Journals (Sweden)

    Remzi Avcı

    2013-01-01

    Full Text Available Lens injury due to traumas may present as loss of capsule integrity, cataract, lens subluxation, or lens luxation. In addition, lens subluxation and lens luxation may occur in pseudophakic patients due to trauma. Clear corneal, scleral or sclero-corneal phacoemulsification surgery, pars plana vitrectomy, pars plana vitrectomy with phaco-fragmentation, or pars plana vitrectomy with removal through corneal incision techniques are used in the treatment of lens injury due to traumas. Intraocular lens can be implanted in the bag, sulcus, or anterior chamber during the surgery. Depending on the circumstances, scleral fixated intraocular lenses or iris-claw lenses may also be preferred. Rehabilitation of such patients is not of a great concern today, with the advanced level of vitreoretinal surgery and cataract surgery techniques and with the current state of technology. (Turk J Ophthalmol 2013; 43: 51-4

  2. The molecular background of the differential UV absorbance of the human lens in the 240-400 nm range.

    Science.gov (United States)

    Pajer, Viktor; Tiboldi, Akos; Bae, Narkhyun; Li, Kongzhao; Kang, Sung Ung; Hopp, Béla; Kolozsvári, Lajos; Lubec, Gert; Nógrádi, Antal

    2013-01-01

    The ultraviolet (UV) absorption of various sections of the human lens was studied and compared with protein expression paralleling differential UV absorbance in anterior and posterior lenticular tissue. The UV absorbance of serial lens cryostat sections (60 μm) and that of lens capsules was determined using a Shimadzu scanning spectrophotometer, and the absorption coefficients were calculated. Two-dimensional gel electrophoresis was performed using two pooled lenticular protein extracts (anterior and posterior sections). Protein spots were quantified and significantly different spots were identified by mass spectrometry following in-gel digestion with trypsin and chymotrypsin. The UV-C and UV-B absorption of the human lens increased toward the posterior parts of the lens. The anterior and posterior lens capsules also effectively absorbed UV radiation. Levels of molecular chaperone proteins Beta-crystallin B2 (UniProtKB ID:P43320), A3 (UniProtKB ID:P05813) and of glyceraldehyde 3-phosphate dehydrogenase (UniProtKB ID:P04406) were significantly higher in the anterior part of the lens, whereas lens proteins Beta-crystallin B1 (UniProtKB ID:P53674) and Alpha-crystallin A chain (UniProtKB ID:P02489) were higher in the posterior sections. These results provide evidence that differential UV absorption in the anterior and posterior lens is accompanied by differential protein expression. © 2013 Wiley Periodicals, Inc. Photochemistry and Photobiology © 2013 The American Society of Photobiology.

  3. Episodic memory following deep brain stimulation of the ventral anterior limb of the internal capsule and electroconvulsive therapy.

    Science.gov (United States)

    Bergfeld, Isidoor O; Mantione, Mariska; Hoogendoorn, Mechteld L C; Horst, Ferdinand; Notten, Peter; Schuurman, P Richard; Denys, Damiaan

    Electroconvulsive Therapy (ECT) and Deep Brain Stimulation (DBS) are effective treatments for patients with treatment-resistant depression (TRD). However, a common side effect of ECT is autobiographical memory loss (e.g., personal experiences), whereas the impact of DBS on autobiographical memories has never been established. Comparing autobiographical memories following DBS and ECT. In two hospitals in The Netherlands, we interviewed 25 TRD patients treated with DBS of the ventral anterior limb of the internal capsule (vALIC), 14 TRD patients treated with ECT and 22 healthy controls (HC) with the Autobiographical Memory Inventory - Short Form (AMI-SF) in a prospective, longitudinal study between March 2010 and August 2016. Patients treated with DBS were interviewed before surgery, after surgery, and twice during treatment over 122.7 (SD: ±22.2) weeks. Patients treated with ECT were tested before ECT, after six right unilateral (RUL) ECT sessions and twice following ECT over 65.1 (±9.3) weeks. Controls were tested four times over 81.5 (±15.6) weeks. Compared to HC, the AMI-SF score decreased faster in both TRD groups (P ECT group was larger than both the DBS and HC groups. Both ECT and vALIC DBS result in a faster autobiographical memory decline compared to HC. DBS might have a negative impact on autobiographical memories, although less so than ECT. Future work should dissect whether DBS or characteristics of TRD cause this decline. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Comparison of the Results of Secondary Anterior Chamber and Secondary Scleral-Fixated Intraocular Lens Implantation in Complicated Phacoemulsification Cases

    Directory of Open Access Journals (Sweden)

    Nimet Yeşim Erçalık

    2014-03-01

    Full Text Available Objectives: To compare the visual prognosis and postoperative complication rates of secondary anterior chamber (AC IOL and scleralfixated (SF intraocular lenses (IOL after complicated phacoemulsification surgery. Materials and Methods: Thirty eyes of thirty patients were reviewed for this retrospective study. The patients with secondary AC IOL implantation formed group 1 (n=15, and the patients with secondary SF IOL implantation formed group 2 (n=15. Best-corrected visual acuity (BCVA with Snellen chart, biomicroscopic examination, intraocular pressure (IOP measurement with applanation tonometer, gonioscopy performed by Goldmann’s 3-mirror contact lens, and fundus examination were performed preoperatively in all patients. Results: There was no statistically significant difference in postoperative BCVA (p=0.492 and postoperative success (BCVA not changed or better postoperatively between the 2 groups (p=0.598. Postoperative success rate was 80% in group 1 and 93.7% in Group 2. The postoperative cylindrical power of the eyes did not differ significantly between the groups (p=0.220. The postoperative complications in group 1 were as follows: transient corneal edema in 5 eyes, transient IOP elevation in 2 eyes, postoperative fibrinous reaction in the anterior chamber in one eye, late-onset secondary glaucoma in one eye, hyphema in one eye, cystoid macular edema in one eye, vitreous prolapse into the anterior chamber in one eye, and IOL malposition in one eye. The postoperative complications in group 2 were as follows: transient corneal edema in 3 eyes, vitreous prolapse into the anterior chamber in 2 eyes, IOL malposition in 2 eyes, transient IOP elevation in one eye, and retinal detachment in one eye. Conclusion: In this study, both IOL types were observed to be preferable in cases without adequate capsular support following complicated cataract surgery. However, further studies with large numbers of patients are needed to define the best choice

  5. Iris-fixated anterior chamber phakic intraocular lens for myopia moves posteriorly with mydriasis.

    NARCIS (Netherlands)

    Cruysberg, L.P.J.; Doors, M.; Berendschot, T.T.; Brabander, J. De; Webers, C.A.; Nuijts, R.M.

    2009-01-01

    PURPOSE: To elucidate the physiological characteristics of eyes implanted with iris-fixated anterior chamber phakic intraocular lenses (pIOLs), which are increasingly being used for the correction of higher myopic and hyperopic refractive errors. METHODS: In a case series of 20 patients (39 eyes),

  6. Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation

    Directory of Open Access Journals (Sweden)

    Sirel Gür Güngör

    2016-12-01

    Full Text Available Objectives: To compare anterior chamber depth (ACD changes after phacoemulsification surgery in patients with pseudoexfoliation syndrome (PEX and normal patients using an anterior segment imaging method. Another aim of this study was to evaluate the effect of these changes on the accuracy of intraocular lens (IOL power calculation and postoperative refraction. Materials and Methods: Twenty-two eyes of 22 patients with PEX and 30 eyes of 30 normal patients who underwent uneventful phacoemulsification surgery and IOL implantation were included in the study. The ACD of all patients was evaluated preoperatively and at 3 months postoperatively with the ALLEGRO Oculyzer (WaveLight® Oculyzer™ II, Alcon, Novartis-Scheimpflug imaging system. Results: The postoperative mean ACD values were significantly larger than the preoperative ACD values in both groups (p<0.001 for both groups. The pre- to postoperative change in ACD was 0.46±0.3 mm in the PEX group, which was a larger change than seen in the normal patients (0.12±0.1 mm (p=0.04. The mean absolute errors (MAE calculated with different IOL formulas (SRK/T, Haigis, Hoffer and Holladay 1 formulas were comparable and no statistically significant difference was observed between the two groups (p=0.21. Conclusion: Phacoemulsification induces more significant ACD changes in patients with PEX compared to normal patients. However, the MAE did not differ significantly between the groups.

  7. Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation

    Science.gov (United States)

    Gür Güngör, Sirel; Akman, Ahmet; Asena, Leyla; Aksoy, Mustafa; Sarıgül Sezenöz, Almila

    2016-01-01

    Objectives: To compare anterior chamber depth (ACD) changes after phacoemulsification surgery in patients with pseudoexfoliation syndrome (PEX) and normal patients using an anterior segment imaging method. Another aim of this study was to evaluate the effect of these changes on the accuracy of intraocular lens (IOL) power calculation and postoperative refraction. Materials and Methods: Twenty-two eyes of 22 patients with PEX and 30 eyes of 30 normal patients who underwent uneventful phacoemulsification surgery and IOL implantation were included in the study. The ACD of all patients was evaluated preoperatively and at 3 months postoperatively with the ALLEGRO Oculyzer (WaveLight® Oculyzer™ II, Alcon, Novartis)-Scheimpflug imaging system. Results: The postoperative mean ACD values were significantly larger than the preoperative ACD values in both groups (p<0.001 for both groups). The pre- to postoperative change in ACD was 0.46±0.3 mm in the PEX group, which was a larger change than seen in the normal patients (0.12±0.1 mm) (p=0.04). The mean absolute errors (MAE) calculated with different IOL formulas (SRK/T, Haigis, Hoffer and Holladay 1 formulas) were comparable and no statistically significant difference was observed between the two groups (p=0.21). Conclusion: Phacoemulsification induces more significant ACD changes in patients with PEX compared to normal patients. However, the MAE did not differ significantly between the groups. PMID:28050320

  8. Clear lens phacoemulsification in the anterior lenticonus due to Alport Syndrome: two case reports

    OpenAIRE

    Aslanzadeh, Ghassem Amir; Gharabaghi, Davoud; Naderi, Niloofar

    2008-01-01

    Abstract Introduction Alport Syndrome has a prevalence of 1 case per 5,000 people and 85% of patients have the X-linked form, where affected males develop renal failure and usually have high-tone sensorineural deafness by age 20. The main abnormality is deficient synthesis of type IV collagen, the main component of basement membranes. Common ocular abnormalities of this syndrome consist of dot-and-fleck retinopathy, posterior polymorphous corneal dystrophy, and anterior lenticonus, but other ...

  9. Outcomes of iris-claw anterior chamber versus iris-fixated foldable intraocular lens in subluxated lens secondary to Marfan syndrome.

    Science.gov (United States)

    Hirashima, Denise E; Soriano, Eduardo S; Meirelles, Rodrigo L; Alberti, Gustave N; Nosé, Walton

    2010-08-01

    To compare the outcome of phacoemulsification using 2 different iris-fixation techniques for intraocular lens (IOL) replacement, a foldable posterior chamber IOL (PCIOL; AcrySof MA60AC, Alcon Laboratories Inc, Fort Worth, TX) and an iris-claw anterior chamber IOL (ACIOL; Artisan, Ophtec BV), for treatment of subluxated lenses in patients with Marfan syndrome (MFS). Randomized, controlled trial. A total of 31 eyes of 16 patients with subluxated lenses associated with MFS and a preoperative corrected visual acuity (CVA) IOL type. Preoperative and postoperative ophthalmologic examination, optical coherence tomography, and endothelial cell counts were performed. We recorded CVA results at 3, 6, and 12 months, complications, endothelial cell loss, and central retinal thickness. In the iris-fixated PCIOL group, CVA was significantly improved at 3 (P = 0.011; n = 16), 6 (P = 0.006; n = 16), and 12 months (P = 0.002; n = 16). In the iris-claw ACIOL group, CVA was significantly improved at 3 (P = 0.001; n=15), 6 (P = 0.001; n = 15), and 12 months (P = 0.009; n = 12). The CVA results did not differ significantly between groups. Dislocation of the IOL occurred in 3 of 16 (18.75%) eyes in the PCIOL group. Retinal detachment occurred in 3 eyes (2 in the PCIOL group and 1 in the ACIOL group) and was successfully repaired. Postoperative foveal tomograms in both groups revealed a decrease in the mean foveal thickness (MFT; IOL dislocation tended to occur more frequently in the iris-fixated PCIOL group, the difference was not significant. At 6 months postoperatively, all study patients tended to have a thinner MFT. None of the patients in either group developed cystoid macular edema. Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  10. Delayed rupture of the extensor hallucis longus and extensor digitorum communis tendons after breaching the anterior capsule with a radiofrequency probe during ankle arthroscopy: a case report.

    Science.gov (United States)

    Tuncer, Serdar; Aksu, Neslihan; Isiklar, Ugur

    2010-01-01

    A 40-year-old man with early arthritis, loose bodies, and anterolateral joint impingement symptoms in his left ankle, which was refractory to noninvasive therapeutic modalities for 1 year, underwent ankle arthroscopy and radiofrequency thermal ablation. The anterior capsule of the ankle joint was breached by the radiofrequency probe while the loose bodies were removed from the anterior recess, exposing the extensor tendons and resulting in a delayed spontaneous rupture of the extensor hallucis longus tendon and extensor tendons to the second and third toes. The extensor hallucis longus tendon was repaired with a semitendinosus tendon graft, and extensor digitorum tendons underwent primary repair. The patient regained full function and was symptom free 1 year after surgery. Copyright 2010 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Randomized controlled trial for efficacy of capsular distension for adhesive capsulitis: fluoroscopy-guided anterior versus ultrasonography-guided posterolateral approach.

    Science.gov (United States)

    Bae, Jae Hyun; Park, Young Sook; Chang, Hyun Jung; Kim, Min Jung; Park, Kang Young; Jin, Seung Hwan; Lee, Eun Hee

    2014-06-01

    To find the most effective procedure to treat adhesive capsulitis of the shoulder, we evaluated the clinical effects of an ultrasonographic-guided anterior approach capsular distension and a fluoroscopy-guided posterolateral approach capsular distension. We expected the anterior approach to be better than the posterolateral approach because the rotator interval, a triangular anatomic area in the anterosuperior aspect of the shoulder, which is considered an important component of the pathology of adhesive capsulitis. PARTICIPANTS WERE RANDOMLY ASSIGNED TO TWO GROUPS: 27 patients in group A were injected by an anterior approach with 2% lidocaine (5 mL), contrast dye (5 mL), triamcinolone (40 mg), and normal saline (9 mL) under fluoroscopic guidance in the operating room. Twenty-seven patients in group B were injected using a posterolateral approach with 2% lidocaine (5 mL), triamcinolone (40 mg), and normal saline (14 mL) under ultrasonographic guidance. After injection, all patients received physiotherapy four times in the first postoperative week and then two times each week for eight more weeks. Treatment effects were assessed using the shoulder pain and disability index (SPADI), visual numeric scale (VNS), passive range of motion (PROM), hand power (grip and pinch) at baseline and at one week, five and nine weeks after injection. SPADI, VNS, PROM, and hand power improved in one week, five and nine weeks in both groups. Statistically significant differences were not observed in SPADI, VNS, PROM, or hand power between groups. Ultrasonography-guided capsular distension by a posterolateral approach has similar effects to fluoroscopy-guided capsular distension by an anterior approach.

  12. Randomized Controlled Trial for Efficacy of Capsular Distension for Adhesive Capsulitis: Fluoroscopy-Guided Anterior Versus Ultrasonography-Guided Posterolateral Approach

    Science.gov (United States)

    Bae, Jae Hyun; Chang, Hyun Jung; Kim, Min Jung; Park, Kang Young; Jin, Seung Hwan; Lee, Eun Hee

    2014-01-01

    Objective To find the most effective procedure to treat adhesive capsulitis of the shoulder, we evaluated the clinical effects of an ultrasonographic-guided anterior approach capsular distension and a fluoroscopy-guided posterolateral approach capsular distension. We expected the anterior approach to be better than the posterolateral approach because the rotator interval, a triangular anatomic area in the anterosuperior aspect of the shoulder, which is considered an important component of the pathology of adhesive capsulitis. Methods Participants were randomly assigned to two groups: 27 patients in group A were injected by an anterior approach with 2% lidocaine (5 mL), contrast dye (5 mL), triamcinolone (40 mg), and normal saline (9 mL) under fluoroscopic guidance in the operating room. Twenty-seven patients in group B were injected using a posterolateral approach with 2% lidocaine (5 mL), triamcinolone (40 mg), and normal saline (14 mL) under ultrasonographic guidance. After injection, all patients received physiotherapy four times in the first postoperative week and then two times each week for eight more weeks. Treatment effects were assessed using the shoulder pain and disability index (SPADI), visual numeric scale (VNS), passive range of motion (PROM), hand power (grip and pinch) at baseline and at one week, five and nine weeks after injection. Results SPADI, VNS, PROM, and hand power improved in one week, five and nine weeks in both groups. Statistically significant differences were not observed in SPADI, VNS, PROM, or hand power between groups. Conclusion Ultrasonography-guided capsular distension by a posterolateral approach has similar effects to fluoroscopy-guided capsular distension by an anterior approach. PMID:25024960

  13. Mutations in ASPH cause facial dysmorphism, lens dislocation, anterior-segment abnormalities, and spontaneous filtering blebs, or Traboulsi syndrome.

    Science.gov (United States)

    Patel, Nisha; Khan, Arif O; Mansour, Ahmad; Mohamed, Jawahir Y; Al-Assiri, Abdullah; Haddad, Randa; Jia, Xiaofei; Xiong, Yong; Mégarbané, André; Traboulsi, Elias I; Alkuraya, Fowzan S

    2014-05-01

    We have previously described a syndrome characterized by facial dysmorphism, lens dislocation, anterior-segment abnormalities, and spontaneous filtering blebs (FDLAB, or Traboulsi syndrome). In view of the consanguineous nature of the affected families and the likely autosomal-recessive inheritance pattern of this syndrome, we undertook autozygosity mapping and whole-exome sequencing to identify ASPH as the disease locus, in which we identified two homozygous mutations. ASPH encodes aspartyl/asparaginyl β-hydroxylase (ASPH), which has been found to hydroxylate aspartic acid and asparagine residues on epidermal growth factor (EGF)-domain-containing proteins. The truncating and missense mutations we identified are predicted to severely impair the enzymatic function of ASPH, which suggests a possible link to other forms of ectopia lentis given that many of the genes implicated in this phenotype encode proteins that harbor EGF domains. Developmental analysis of Asph revealed an expression pattern consistent with the proposed link to the human syndrome. Indeed, Asph-knockout mice had a foreshortened snout, which corresponds to the facial abnormalities in individuals with Traboulsi syndrome. These data support a genetic basis for a syndromic form of ectopia lentis and the role of aspartyl hydroxylation in human development. Copyright © 2014 The American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  14. Anterior chamber depth and iris and lens position before and after phacoemulsification in eyes with a short or long axial length.

    Science.gov (United States)

    Muzyka-Woźniak, Maria; Ogar, Angelika

    2016-04-01

    To evaluate changes in anterior segment parameters after phacoemulsification in short eyes and long eyes. Spektrum Eye Clinic, Wrocław, Poland. Prospective comparative study. Anterior segment parameters were examined before and after phacoemulsification in 3 groups of eyes as follows: short (axial length [AL] 25.5 mm) with optical biometry based on partial coherence interferometry (IOLMaster) and anterior segment optical coherence tomography (Visante). The study comprised 20 short eyes, 22 normal eyes, and 19 long eyes. The anterior chamber angle increased after surgery in all eyes (P position after phacoemulsification was larger in short eyes than in normal or long eyes (mean change 0.93 mm, 0.70 mm, and 0.43 mm, respectively) (P position after phacoemulsification in relation to the iris was smaller in short eyes (mean 0.51 mm) than in normal or long eyes (mean 0.82 mm and 1.10 mm, respectively) (P position occurred in short eyes. The largest change in the lens versus the intraocular lens (IOL) position occurred in long eyes, with the IOL moving back from the iris. Optical biometry might underestimate the postoperative ACD. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Sectioning a luxated intraocular lens inside the vitreous cavity.

    Science.gov (United States)

    Vilaplana, Daniel; Pazos, Marta

    2013-07-01

    We describe a new technique for sectioning an intraocular lens (IOL) inside the vitreous cavity. The IOL had a broken haptic and was accidentally luxated after a complicated cataract surgery with posterior capsule rupture. The primary indication to cut the IOL in half inside the vitreous cavity is to preserve the anterior capsule integrity, especially in a small-sized capsulotomy, allowing subsequent implantation of a new IOL in the sulcus with the optical zone captured in the capsulorhexis. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Mechanism research of miR-181 regulating human lens epithelial cell apoptosis

    Directory of Open Access Journals (Sweden)

    Yu Qin

    2015-05-01

    Full Text Available AIM: To investigate the expression of miR-181 in the lens tissue of cataract and the regulating mechanism of miR-181 on apoptosis of human lens epithelial cell.METHODS:Real time q-PCR was used to measure the expression of miR-181 in the anterior lens capsules of age-related cataract and human lens epithelial cell apoptosis model. miR-181 mimic and inhibitor were transfected using Lipofectamine 2 000 to regulate the expression of miR-181, and then Real time q-PCR was used to verify transfection efficiency. Flow cytometry was used to detect the change of cell apoptosis rate. RESULTS: Compared with control group, the expression of miR-181 was significantly higher in both the anterior lens capsules of age-related cataract and human lens epithelial cell apoptosis model; the relative expression of miR-181 in lens epithelial cells transfected with miR-181 mimic was increased, whereas decreased in cells transfected with miR-181 inhibitor; the apoptosis rate of cells transfected with miR-181 mimic was increased, while reduced in miR-181 inhibitor group. Each result was statistically significant(PCONCLUSION: High expression of miR-181 is detected in anterior lens capsule of age-related cataract. miR-181 might play a certain role in the pathogenesis of cataract via promoting human lens epithelial cell apoptosis. miR-181 probably becomes a new approach for the nonoperative treatment of cataract, but the concrete mechanism still needs to be further studied.

  17. Capsular phimosis with complete occlusion of the anterior capsular opening after intact continuous curvilinear capsulorrhexis

    International Nuclear Information System (INIS)

    AlKharashi, Soliman A

    2009-01-01

    Shrinkage and whitening of the anterior capsule opening - capsular contraction syndrome - is a well-known complication after continuous curvilinear capsulorrhexis. A 72-year-old women underwent continuous curvilinear capsulorrhexis, phacoemulsification, and implantation of posterior chamber intraocular lens with polymethylmethacrylate haptics. Four months postoperatively, the patient reported deterioration in visual acuity that was resulted due to complete occlusion of anterior capsular opening by fibrotic tissue. The fibrous membrane was excised surgically in capsulorrhexis fashion. (author)

  18. Lens Epithelial Cell Death Secondary to Acanthamoeba Keratitis: Absence of Capsular Bag Opacification Six Years after Cataract Surgery

    Directory of Open Access Journals (Sweden)

    Javier Moreno-Montañés

    2011-12-01

    Full Text Available Purpose: To show the evolution of anterior chamber structures 6 years after cataract surgery in a case with Acanthamoeba keratitis (AK. Methods: A 37-year-old woman with AK receiving long-term treatment with chlorhexidine, propamidine isethionate and steroids developed a white cataract and iris atrophy. Penetrating keratoplasty and cataract surgery were performed with subsequent intraocular pressure elevation requiring Molteno shunt implantation. Two years after the last surgery, endothelial decompensation developed and another penetrating keratoplasty was performed. Intraoperatively, the anterior and posterior capsules were completely transparent. Results: Six years after cataract surgery, the intraocular lens was centered with clear anterior and posterior capsules without lens epithelial cells proliferation. No Soemmering’s ring formation or posterior capsule opacification was found. Also, no zonular damage or pseudophacodonesis was observed. Conclusions: This case suggests that AK infection and AK treatment not only cause white progressive cataract but also lens epithelial cell death. The capsules may be completely clear 6 years after cataract surgery, with a good quality of vision regardless of intraocular lens material or design.

  19. Primary intraocular lens implantation for penetrating lens trauma in Africa.

    Science.gov (United States)

    Bowman, R J; Yorston, D; Wood, M; Gilbert, C; Foster, A

    1998-09-01

    This study aimed to audit the surgical strategy of primary posterior chamber intraocular lens implantation for cases of recent penetrating trauma involving the lens in an African population. Retrospective, noncomparative case series. Seventy-two cases are reported, including all patients who underwent primary intraocular lens implantation for traumatic cataract extraction performed within 1 month of injury between 1988 and 1996. Demographic characteristics and follow-up attendance rates are analyzed. Surgical technique and the occurrence of intraoperative and postoperative complications are reported. Visual outcomes are reported with detailed analysis for cases of poor visual outcome. Mean age was 14.3 years (standard deviation = 11.1), 57 (79%) were male and 15 (21%) were female (chi-square = 23.66, P capsule had been breached by the trauma in 27 (38%) cases, and 15 of these required anterior vitrectomy. Capsular fixation of the implant was achieved in 49% of patients, the remainder having sulcus fixation. Intraoperative rupture of the posterior capsule occurred in four cases. The only common postoperative complication was acute fibrinous anterior uveitis, which occurred in 29 (40%) patients, and 32% of patients followed up for at least 6 months required secondary posterior capsulotomy. This was more common in younger patients (chi-square = 4.2, P < 0.05). Corrected postoperative visual acuities were available for 51 patients, of which 71% achieved 20/60 or better visual acuity. Patients 6 years of age or younger were less likely to achieve 20/60 (chi-square = 6.61, P = 0.01). This surgical strategy has proved successful, producing good visual results and causing no sight-threatening complications. Primary posterior capsulotomy may be appropriate for younger patients.

  20. Combined pars plana lensectomy-vitrectomy with open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for subluxated lenses.

    Science.gov (United States)

    Kazemi, S; Wirostko, W J; Sinha, S; Mieler, W F; Koenig, S B; Sheth, B P

    2000-01-01

    To review our experience with combined pars plana lensectomy-vitrectomy and open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for managing subluxated crystalline lenses. Retrospective review of 36 consecutive eyes (28 patients), all of which had subluxated crystalline lenses, managed by pars plana lensectomy-vitrectomy with insertion of an open-loop flexible AC IOL. The study was performed at the Medical College of Wisconsin, Milwaukee, over an 8-year period. An average preoperative visual acuity of 20/163 (range, 20/25 to hand motions) improved to 20/36 (range, 20/20 to 4/200) with surgery after a mean follow-up of 14 months (range, 1 to 59 months) (P IOL implantation appears to be an excellent technique for managing subluxated crystalline lenses. It is associated with a significant improvement in visual acuity (P subluxated lens through a limbal wound. Additionally, use of an AC IOL offers a simplified alternative to placement of a ciliary sulcus sutured posterior chamber intraocular lens (PC IOL).

  1. Myo/Nog cells: targets for preventing the accumulation of skeletal muscle-like cells in the human lens.

    Directory of Open Access Journals (Sweden)

    Jacquelyn Gerhart

    Full Text Available Posterior capsule opacification (PCO is a vision impairing condition that arises in some patients following cataract surgery. The fibrotic form of PCO is caused by myofibroblasts that may emerge in the lens years after surgery. In the chick embryo lens, myofibroblasts are derived from Myo/Nog cells that are identified by their expression of the skeletal muscle specific transcription factor MyoD, the bone morphogenetic protein inhibitor Noggin, and the epitope recognized by the G8 monoclonal antibody. The goal of this study was to test the hypothesis that depletion of Myo/Nog cells will prevent the accumulation of myofibroblasts in human lens tissue. Myo/Nog cells were present in anterior, equatorial and bow regions of the human lens, cornea and ciliary processes. In anterior lens tissue removed by capsulorhexis, Myo/Nog cells had synthesized myofibroblast and skeletal muscle proteins, including vimentin, MyoD and sarcomeric myosin. Alpha smooth muscle actin (α-SMA was detected in a subpopulation of Myo/Nog cells. Areas of the capsule denuded of epithelial cells were surrounded by Myo/Nog cells. Some of these cell free areas contained a wrinkle in the capsule. Depletion of Myo/Nog cells eliminated cells expressing skeletal muscle proteins in 5-day cultures but did not affect cells immunoreactive for beaded filament proteins that accumulate in differentiating lens epithelial cells. Transforming growth factor-betas 1 and 2 that mediate an epithelial-mesenchymal transition, did not induce the expression of skeletal muscle proteins in lens cells following Myo/Nog cell depletion. This study demonstrates that Myo/Nog cells in anterior lens tissue removed from cataract patients have undergone a partial differentiation to skeletal muscle. Myo/Nog cells appear to be the source of skeletal muscle-like cells in explants of human lens tissue. Targeting Myo/Nog cells with the G8 antibody during cataract surgery may reduce the incidence of PCO.

  2. Supracapsular glued intraocular lens in progressive subluxated cataracts: Technique to retain an intact vitreous face.

    Science.gov (United States)

    Jacob, Soosan; Narasimhan, Smita; Agarwal, Amar; Mazzotta, Cosimo; Rechichi, Miguel; Agarwal, Athiya

    2017-03-01

    We describe a technique to prevent late intraocular lens (IOL) subluxation and dislocation that can be associated with progressive zonulopathy. Supracapsular glued IOL fixation is done to retain an intact anterior hyaloid face and avoid vitreous disturbance while providing stable long-term IOL fixation. Phacoemulsification is followed by glued IOL implantation above intact anterior and posterior capsules. Sclerotomies are created ab interno in a supracapsular plane under diametrically opposite lamellar scleral flaps without entering the vitreous cavity. Haptics are externalized in the supracapsular plane and tucked into intrascleral tunnels. Intraoperative or postoperative posterior capsulorhexis or capsulotomy and anterior capsule relaxing cuts can prevent capsule phimosis. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Corneal Collagen Cross-Linking Combined with an Artiflex Iris-Fixated Anterior Chamber Phakic Intraocular Lens Implantation in a Patient with Progressive Keratoconus

    Directory of Open Access Journals (Sweden)

    Sharif Hashmani

    2017-10-01

    Full Text Available We present here the case of a 24-year-old male who experienced progressive keratoconus and vision loss which adversely affected his ability to carry out everyday tasks. This landed him in the Hashmanis Hospital for consultation. He had a preoperative best corrected visual acuity of 6/12. He underwent multiple Oculus Pentacam examinations, which showed progressive keratoconus. Corneal collagen cross-linking (CXL was performed to stabilize his cornea and, subsequently, an Artiflex anterior chamber iris-fixated phakic intraocular lens (ACIF-PIOL was implanted to alleviate his refractive errors. The patient achieved a postoperative uncorrected visual acuity of 6/12. This report shows that CXL combined with ACIF-PIOL can be safe and effective in those with progressive keratoconus.

  4. Anterior capsular staining with trypan blue for capsulorhexis in mature and hypermature cataracts. A preliminary study

    Directory of Open Access Journals (Sweden)

    Kothari Kulin

    2001-01-01

    Full Text Available Purpose: To study the efficacy and safety of 0.1% Trypan Blue dye to stain the anterior capsule for capsulorhexis in mature and hypermature cataracts. Methods: This preliminary study included 25 eyes of 25 patients with a unilateral mature or hypermature cataract, including one case of traumatic mature cataract. In all these cases 0.2ml of 0.1% trypan blue dye was used to stain the anterior capsule. The efficacy and safety of the dye was evaluated on the basis of intraoperative and postoperative observations. Results: In all 25 eyes the capsulorhexis was completed. There was peripheral extension of the capsulorhexis in the eye with traumatic cataract and the stained edge of the anterior capsule helped identification and redirection of the capsulorhexis. Successful phacoemulsification with intraocular lens implantation was performed in all eyes. Adverse reactions related to the dye such as raised intraocular pressure, anterior chamber inflammation and endothelial damage were not observed in the immediate postoperative period or at the end of mean follow-up of 3 months. Conclusion: Trypan blue dye staining of the anterior capsule appears to be a very useful and safe technique that simplifies capsulorhexis in mature and hypermature cataracts.

  5. No stabilizing effect of the elbow joint capsule. A kinematic study

    DEFF Research Database (Denmark)

    Nielsen, K K; Olsen, Bo Sanderhoff

    1999-01-01

    We dissected 7 cadaveric elbow specimens, leaving the collateral ligaments and the joint capsule intact. The anterior and the posterior capsule were sequentially transected, followed by kinematic testings. We found no change in joint laxity after total transection of the capsule.......We dissected 7 cadaveric elbow specimens, leaving the collateral ligaments and the joint capsule intact. The anterior and the posterior capsule were sequentially transected, followed by kinematic testings. We found no change in joint laxity after total transection of the capsule....

  6. opened capsule

    African Journals Online (AJOL)

    The accuracy of the off-label opened capsule dosing method for stavudine is acceptable. There is no need to instruct caregivers to include sediment in the aliquot given to the infant. However, studies that confirm adequate bioavailability and efficacy are needed. In addition, it is important to avoid supplying generic capsules ...

  7. Encephalitozoon cuniculi causes focal anterior cataract and uveitis in dogs.

    Science.gov (United States)

    Nell, B; Csokai, J; Fuchs-Baumgartinger, A; Maaß, G

    2015-01-01

    Three mongrel dogs, aged 10 months (case 1), 14 months (case 2) and 7.5 years (case 3), were presented because of ophthalmologic disorders of 4 months, 6 months and 7 years duration, respectively. All three dogs were offspring of stray dogs from Hungary and Serbia and had positive serum antibody titres against Encephalitozoon (E.) cuniculi. The two young dogs showed unilateral, the older dog bilateral chronic anterior uveitis with posterior synechia and focal anterior cortical cataract. The fundi that could be evaluated developed focal tapetal hyporeflective lesions in the course of the disease. Dogs 1 and 2 underwent removal of the lens via phacoemulsification. PCR of the lens material was positive for E. cuniculi strains IV and II, respectively. In dog 2 findings suggestive of microsporidia were detected underneath the anterior lens capsule by immunohistochemical staining. In all cases medical treatment consisted of systemic fenbendazole, prednisolone, and topical anti-inflammatory drugs, and additional brinzolamid/timolol for dog 3. For the time being all cases (follow up 23 months, 6 months and 3 months, respectively) are still on topical anti-inflammatory therapy. It is concluded that E. cuniculi infections can cause cataract and chorioretinal lesions in dogs.

  8. Contaminação bacteriana da câmara anterior pós-facoemulsificação com implante de lente intra-ocular de polimetilmetacrilato ou silicone Bacterial anterior chamber contamination after phacoemulsification and polymethylmethacrylate or silicone intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Ricardo Antonio Pereira

    2004-12-01

    Full Text Available OBJETIVO: Avaliar a contaminação bacteriana da câmara anterior, após facoemulsificação não complicada, com tamanhos diferentes de incisões e lentes intra-oculares. MÉTODOS: Foi realizado estudo prospectivo randomizado, de 80 olhos de 80 pacientes, submetidos à facoemulsificação sob anestesia tópica, distribuídos aleatoriamente em dois grupos iguais. No grupo A foram alocados os pacientes submetidos à cirurgia com incisão de 3,0 mm, lente intra-ocular dobrável de silicone implantadas com injetor. No grupo B os pacientes foram submetidos à cirurgia com incisão de 5,8 mm e implante de lente intra-ocular de polimetilmetacrilato de peça única, com pinça. Ao final de cada cirurgia, uma amostra do líquido da câmara anterior foi colhida e semeada em meios de cultura para bactérias. RESULTADOS: A cultura do líquido da câmara anterior foi positiva em 2,5% dos casos do grupo A e em 5,0% do grupo B. Não houve diferença estatisticamente significante entre os dois grupos (chi2 = 0, 380, p> 0,05. CONCLUSÃO: O implante de lente intra-ocular através de incisão menor, não resultou em menor contaminação da câmara anterior na cirurgia de facoemulsificação.PURPOSE: To evaluate bacterial anterior chamber contamination following uncomplicated phacoemulsification with differents sizes of incisions. METHODS: Prospective randomized study, 80 eyes, 80 patients divided into two groups, were submitted to phacoemulsification with topical anaesthesia. In group A, with 40 patients, surgery was perfomed with 3.0 mm incision and silicone intraocular lens implant with injector. In group B the surgery was done with 5.8 mm incision and polymethylmethacrylate intraocular lens implant with forceps. Anterior chamber aspirate was taken for culture upon completion of surgery in each case. RESULTS: Anterior chamber cultures were positive in 2.5% of the cases in group A, and 5.0% in group B (chi-square test = 0.380, p>0.05, frequencies of

  9. Anterior capsulotomy with an ultrashort-pulse laser.

    Science.gov (United States)

    Tackman, Ramon Naranjo; Kuri, Jorge Villar; Nichamin, Louis D Skip; Edwards, Keith

    2011-05-01

    To assess the precision of laser anterior capsulotomy compared with that of manual continuous curvilinear capsulorhexis (CCC). Asociación Para Evitar La Ceguera en México IAP, Hospital Dr. Luis Sánchez Bulnes, Mexico City, Mexico. Nonrandomized single-center clinical trial. In patients presenting for cataract surgery, the LensAR Laser System was used to create a laser anterior capsulotomy of the surgeon's desired size. Capsule buttons were retrieved and measured and then compared with buttons retrieved from eyes having a manually torn CCC. Deviation from the intended diameter and the regularity of shape were assessed. When removing the capsule buttons at the start of surgery, the surgeon rated the ease of removal on a scale of 1 to 10 (1 = required manual capsulorhexis around the whole diameter; 10 = button free floating or required no manual detachment from remaining capsule during removal). The mean deviation from the intended diameter was 0.16 mm ± 0.17 (SD) for laser anterior capsulotomy and 0.42 ± 0.54 mm for CCC (P=.03). The mean absolute deviation from the intended diameter was 0.20 ± 0.12 mm and 0.49 ± 0.47 mm, respectively (P=.003). The mean of the average squared residuals was 0.01 ± 0.03 and 0.02 ± 0.04, respectively (P=.09). The median rating of the ease of removal was 9 (range 5 to 10). Laser anterior capsulotomy created a more precise capsule opening than CCC, and the buttons created by the laser procedure were easy to remove at the beginning of cataract surgery. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Avaliação da contaminação da câmara anterior na cirurgia de facoemulsificação com implante de lente intra-ocular Anterior chamber contamination in phacoemulsification surgery with intraocular lens implant

    Directory of Open Access Journals (Sweden)

    Cesar Nobuo Shiratori

    2002-06-01

    Full Text Available Objetivo: Avaliar a existência de contaminação da câmara anterior durante a facectomia por facoemulsificação com implante de lente intra-ocular. Método: Foi realizado estudo prospectivo, avaliando-se 30 pacientes submetidos a facectomia por facoemulsificação com implante de lente intra-ocular, colhendo-se duas amostras de humor aquoso, uma obtida no início e outra no final da cirurgia. As amostras foram semeadas em meio de cultura para germes aeróbios, anaeróbios e fungos. Resultado: Todas as amostras avaliadas resultaram negativas. Conclusão: A contaminação da câmara anterior na cirurgia de facoemulsificação com implante de lente intra-ocular, usando os cuidados necessários, é infreqüente.Purpose: To evaluate the frequency of anterior chamber contamination during phacoemulsification surgery with intraocular lens implant. Method: A prospective study was done with 30 patients submitted to phacoemulsification surgery with intraocular lens implant. Two samples of the aqueous humor were removed from the anterior chamber, one at the beginning and another one at the end of the surgery and were inoculated in culture plates for anaerobic and aerobic bacteria and fungi. Results: Intraocular aspirates yielded negative cultures. Conclusion: The absence of microorganisms in the samples evaluated allowed us to conclude that contamination during the phacoemulsification surgery with lens implant is unusual.

  11. Effects of hyperbaric oxygen on crystalline lens and retina in nicotine-exposed rats.

    Science.gov (United States)

    Ari, Seyhmus; Nergiz, Yusuf; Cingü, Abdullah Kürşat; Atay, Ahmet Engin; Sahin, Alparslan; Cinar, Yasin; Caca, Ihsan

    2013-03-01

    To determine histopathological changes on crystalline lens and retina of rats after subcutaneous injection of nicotine and to examine the effects of hyperbaric oxygen (HBO) on these changes related to nicotine exposure. Twenty-eight female Sprague-Dawley rats were enrolled in the study and the rats were divided into four equal sized groups randomly (Group N: the rats exposed only to nicotine, group HB: the rats received only HBO, group N+HB: the rats that underwent to nicotine injection and subsequently received HBO, group C: the control group that neither exposed to nicotine nor received HBO). The rats were sacrificed by decapitation method and all were enucleated immediately after scarification. Tissue samples from crystalline lens, lens capsule, and the retina from the right eyes of the rats were examined by light microscopy. While the histological appearances of the retina and the lens was similar in group HB, group N+HB, and the control group; group N showed some pathological changes like decrement in the retinal ganglion cell density, atrophy of the retinal nerve fiber layer, congestion of the vessels in the optic nerve head, thinning of the internal plexiform layer, thinning of the lens capsule, and transformation of the anterior subcapsular epithelium into squamous epithelia. Subcutaneous injection of nicotine was found to be related with some pathological changes in the retina and lens of the Sprague-Dawley rats. However HBO caused no significant negative effect. Furthermore, the histopathological changes related to nicotine exposure in the lens and retina of the rats recovered by the application of HBO.

  12. Results and complications of scleral fixated (Sutured posterior chamber intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Amoozadeh J

    2001-08-01

    Full Text Available Optical rehabilitation of the patient with aphakia who cannot tolerate contact lenses present a therapeutic challenge. In the absence of capsular support, anterior chamber lenses have been widely used. On the other hand intraocular lens implantation of scleral sutured posterior chamber intraocular lens during penterating keratoplasty or insufficient iris support is recommended. The purpose of this study is to evaluate the clinical outcome and complication in 17 patients who underwent scleral-fixation of an intraocular lens.We studied prospectively the results of posterior chamber intraocular lens implantation by scleral fixation in 17 eyes of 17 patients without a complete posterior lens capsule support at farabi Eye Hospital. Uncorrected visual acuity improved from counting finger to 20/40 or better in 9 eyes (53 percent. The following complications were observed during the mean postoperative follow-up of 7.2 (range 3-12 months; increased intraocular pressure in 5 eyes, vitreous hemorrhage and icr hyphema in 2 eyes, cystoid macular edema (CME and vitritis in one eye, and endophthalmitis and retinal detachment in one eye. Posterior chamber intraocular lens implantation by scleral fixation is a relatively safe procedure and can be recommended for many patients

  13. Capsule endoscopy

    DEFF Research Database (Denmark)

    Skovsen, Anders Peter; Burcharth, Jakob; Burgdorf, Stefan Kobbelgaard

    2013-01-01

    with ultrasound, MRI, and subsequently a capsule endoscopy. Six months later, the patient presented, and an abdominal CT-scan showed mechanical small bowel obstruction with suspicion of metallic foreign body and perforation. Laparotomy showed perforation, stenosis, and foreign body, approximately 5 cm from...

  14. Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation.

    NARCIS (Netherlands)

    Doors, M.; Cruysberg, L.P.J.; Berendschot, T.T.; Brabander, J. De; Verbakel, F.; Webers, C.A.; Nuijts, R.M.

    2009-01-01

    BACKGROUND: The repeatability and interchangeability of imaging devices measuring central corneal thickness (CCT) and anterior chamber depth (ACD) are important in the assessment of patients considering refractive surgery. The purpose of this study was to investigate the agreement of CCT and ACD

  15. Bilateral intraocular lens subluxation secondary to haptic angulation.

    Science.gov (United States)

    Moreno-Montañés, Javier; Fernández-Hortelano, Ana; Caire, Josemaría

    2008-04-01

    An 82-year-old man had uneventful phacoemulsification with bilateral implantation of a hydrophilic acrylic, single-piece intraocular lens (IOL) (ACR6D SE, Laboratoires Cornéal). Five years later, simultaneous and bilateral IOL subluxations occurred. In both eyes, the subluxation was situated on the side of one haptic that had moved forward (temporal area in the right eye and superior area in the left eye). In the right eye, the haptic-capsular bag was entrapped by the pupil and produced endothelial damage. A transscleral suture was placed over and under the subluxated haptic through the anterior and posterior capsules to capture the haptic. The haptic was then sutured to the sclera. No postoperative complications developed. We hypothesize that 10-degree angulated and broad haptic junctions can lead to zonular damage and IOL subluxation.

  16. Spontaneous dislocation of lens bag with acrylic lens after uneventful cataract surgery - unusual complication of cataract surgery.

    Science.gov (United States)

    Shah, Mehul A; Shah, Shreya M; Mehta, Ruchir; Shah, Prerna

    2015-01-01

    Spontaneous dislocation of intraocular lens with bag is rare. We report a case of a 56-year-old male who presented with spontaneous anterior dislocation of an in-the-bag intraocular lens 3 years after manual small incision cataract surgery. He had undergone manual small incision cataract surgery with foldable acrylic intraocular lens implantation, and 18 months after cataract surgery ND: YAG capsulotomy with uneventful post capsulotomy follow-up. 17 months after capsulotomy, the patient presented with sudden decrease of vision. On anterior segment examination, the intraocular lens with bag was dislocated into the anterior chamber. It was managed with intraocular lens explantation with bag, anterior vitrectomy and sclera fixated intraocular lens. Spontaneous intraocular lens dislocation with bag is possible after 1.5 years of uneventful surgery which may be managed using different techniques.

  17. Posterior capsule opacification and neovascularization treated with intravitreal bevacizumab and Nd:YAG capsulotomy

    Directory of Open Access Journals (Sweden)

    Grimelda Yuriana Sánchez-Castro

    2008-10-01

    Full Text Available Grimelda Yuriana Sánchez-Castro1, Alejandra Hitos-Fájer1, Erick Mendoza-Schuster1, Raul Velez-Montoya2, Cecilio Francisco Velasco-Barona11Asociación para Evitar la Ceguera en México. Hospital “Dr. Luis Sánchez Bulnes”, México, D.F. Ophthalmology Department – Anterior Segment; 2Asociación para Evitar la Ceguera en México. Hospital “Dr. Luis Sánchez Bulnes”, México, D.F. Ophthalmology Department – Retina departmentAbstract: We reported a 75-year-old diabetic man, who developed opacification and neovascularization of the posterior capsule after extracapsular cataract extraction and posterior chamber intraocular lens implantation. The patient was treated with two injections of 2.5 mg of intravitreal bevacizumab. The treatment produced an important regression of the posterior capsular new vessels, allowing us to perform a successful Nd:YAG capsulotomy, clearing the visual axis and improving the visualization of the posterior pole. Even though, best corrected visual acuity was 20/200 due to diabetic macular edema.Keywords: posterior capsule opacification, posterior capsule neovascularization, cataract surgery, postoperative complications, intravitreal bevacizumab

  18. Regional Variation Is Present in Elbow Capsules after Injury

    OpenAIRE

    Germscheid, Niccole M.; Hildebrand, Kevin A.

    2006-01-01

    Myofibroblast numbers and α-smooth muscle actin expression are increased in anterior joint capsules of patients with posttraumatic elbow contractures. The purpose of our study was to determine whether these changes occur regionally or throughout the entire joint capsule. We hypothesized that the α-smooth muscle actin mRNA expression and the myofibroblast numbers in posterior joint capsules would be elevated in elbows obtained from patients with posttraumatic joint contractures compared with j...

  19. Myofibroblast Numbers are Elevated in Human Elbow Capsules After Trauma

    OpenAIRE

    Hildebrand, Kevin A.; Zhang, Mei; van Snellenberg, Wistara; King, Graham J. W.; Hart, David A.

    2004-01-01

    Elbow contractures, a frequent problem after injury, can be treated by excision of the joint capsule. However, the underlying changes in the joint capsule are poorly understood. Based on skin healing work, we examined the hypotheses that myofibroblast numbers and expression of a myofibroblast marker α-smooth muscle actin, are elevated in patients with posttraumatic joint contractures. Anterior capsules were obtained from six patients who had operative release of posttraumatic contractures gre...

  20. The Role of Type IV Collagen in Developing Lens in Mouse Fetuses

    Directory of Open Access Journals (Sweden)

    Mehdi Jalali

    2009-09-01

    Full Text Available Objective(sExtracellular matrix (ECM and basement membrane (BM play important roles in many developmental processes during development and after birth. Among the components of the BM, collagen fibers specially type IV are the most important parts. The aim of this study was to determine the time when collagen type IV appears in the BM of lens structure during mouse embryonic development.Materials and MethodsIn this experimental study, 22 female Balb/C mice were randomly selected and were kept under normal condition, finding vaginal plug was assumed as day zero of pregnancy. From embryonic day 10 to 20, all specimens were sacrificed by cervical dislocation and their heads were fixed, serially sectioned and immunohistochemistry study for tracing collagen type IV in lens were carried out.ResultsOur data revealed that collagen type IV appeared at the early stage of gestation day 12 in BM of anterior epithelial lens cells and the amount of this protein gradually increased until days 15-17 in ECM and posterior capsule epithelium. After this period, severe reaction was not observed in any part of the lens.ConclusionThese findings establish the important role of collagen IV in developing optic cup and any changes during critical period of pregnancy may be result in severe visual system defect

  1. Modified suturing contact lens for penetrating keratoplasty.

    Science.gov (United States)

    Kramer, S G; Stewart, H L

    1978-11-01

    The authors have previously described a suturing contact lens that protects the corneal endothelium by aiding in the maintenance of the anterior chamber during penetrating keratoplasty. This report describes structural modifications of the suturing contact lens, which improve its stability and effectiveness. An additional configuration for use in corneal lacerations is presented.

  2. Incidência de opacificação de cápsula posterior em pacientes submetidos à facoemulsificação e implante de lentes intra-oculares acrílicas hidrofílicas expansíveis Incidence of posterior capsule opacification in patients submitted to phacoemulsification and expandable acrylic intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Hilton Arcoverde Gonçalves de Medeiros

    2006-06-01

    Full Text Available OBJETIVO: Avaliar prospectivamente os resultados das lentes intra-oculares de polímeros expansíveis implantadas em pacientes submetidos à facoemulsificação, quanto à incidência de opacificação de cápsula posterior, levando em consideração a biocompatibilidade das lentes expansíveis. MÉTODOS: O grupo de estudo foi composto por 830 pacientes, 1.200 olhos, que foram submetidos a facoemulsificação, utilizando a mesma técnica, variando-se apenas o diâmetro da capsulorrexe, pelo mesmo cirurgião, no período de 1998 a 2002, com implante de lente intra-ocular hidrofílica expansível. O acompanhamento médio foi de 2,4 anos, variando de seis meses a quatro anos. RESULTADOS: O número total de opacificação de cápsula posterior foi de 54 casos. CONCLUSÃO: A incidência de opacificação de cápsula posterior encontrada no grupo foi de 4,6%.PURPOSE: To evaluate prospectively the results of expandable acrylic intraocular lenses in patients submitted to phacoemulsification as regard posterior capsule opacification. METHODS: The study group consisted of 830 patients, 1,200 eyes that underwent phacoemulsification from 1998 to 2002, by the same surgeon, using the same technique but with different diameters of capsulorrhexis, with expandable hydrophilic acrylic intraocular lens implantation. The mean follow-up was 2.4 years, ranging from 6 months to 4 years. RESULTS: The total number of posterior capsule opacification was 54 cases. CONCLUSIONS: The incidence of posterior capsule opacification was 4.6% in these patients.

  3. Objective lens

    Science.gov (United States)

    Olczak, Eugene G. (Inventor)

    2011-01-01

    An objective lens and a method for using same. The objective lens has a first end, a second end, and a plurality of optical elements. The optical elements are positioned between the first end and the second end and are at least substantially symmetric about a plane centered between the first end and the second end.

  4. Current and future concepts of the design of the intraocular lens.

    Science.gov (United States)

    Jaffe, N S

    1985-01-01

    Anterior chamber lenses are currently much less popular than posterior chamber lenses. They are mainly used in conjunction with intracapsular cataract extraction, as a secondary lens implant, and as a back up lens in case of intraoperative complications of extracapsular cataract extraction. A major disadvantage of anterior chamber lenses is improper sizing. Rigid lenses cause the greatest ocular tenderness and present serious problems with errors in sizing but they are the easiest to explant. Semiflexible and flexible lenses show a greater tendency to develop peripheral anterior synechiae. This makes explanation a very difficult procedure. Posterior chamber lenses are the most popular today. There is a trend toward all-PMMA lenses because of concern over the biocompatibility of polypropylene. The use of a laser ridge may inhibit posterior capsule opacification and facilitate YAG laser posterior capsulectomy. Ultraviolet blockers are being incorporated as a copolymer of a mechanical additive. There is a major trend towards capsular bag fixation of posterior chamber lenses as a result of complications associated with sulcus-fixated lenses. These include: disruption of the blood-aqueous barrier due to loop penetration of the ciliary body; chafing of the posterior surface of the iris leading to transillumination defects, microhyphaemas, and pigment dispersion glaucoma. It is predicted that the number of cataract extractions and the percentage of intraocular lens implantations will continue to increase due to demographic factors. Budgetary allocations for research and development will increase because of the involvement of some of the giants of medical industry. This will lead to new implant materials and new surgical techniques.

  5. Adhesive Capsulitis of the Shoulder Joint: Value of Glenohumeral Distance on Magnetic Resonance Arthrography.

    Science.gov (United States)

    Lee, Kyu Hong; Park, Hee Jin; Lee, So Yeon; Youn, In Young; Kim, Eugene; Park, Jai Hyung; Park, Se Jin

    2017-01-01

    To evaluate the usefulness of glenohumeral distance (GHD) on axial images of magnetic resonance (MR) arthrography for diagnosis of adhesive capsulitis and to compare this finding with previously reported classic MR arthrographic findings of adhesive capsulitis. Our study was approved by the institutional ethical review board of our institute. We evaluated 41 patients (M-F, 35:6; mean age, 46 years; adhesive capsulitis, 21; no adhesive capsulitis, 20) who underwent MR arthrography. Two radiologists measured GHD, width of the axillary recess, and capsular thickness in consensus. The GHD was measured from the subchondral bone of the glenoid fossa to the subchondral bone of the humeral head at the level of the midline of the humeral head. Glenohumeral distance (anterior, middle, posterior, and mean), width of the axillary recess, and capsular thickness (anterior, posterior, and mean) were compared in the adhesive capsulitis and no adhesive capsulitis groups using the Mann-Whitney U test. The mean GHD of the no adhesive capsulitis group was longer than that of the adhesive capsulitis group. The length differences were statistically significant (P adhesive capsulitis group was significantly wider than that of the adhesive capsulitis group (P adhesive capsulitis group was significantly thinner than that in the adhesive capsulitis group (P = 0.001). A decreased GHD on MR arthrography can be another useful feature to diagnose adhesive capsulitis in addition to previously presented radiologic features such as capsular thickening and reduced axillary recess capacity.

  6. TUG1 promotes lens epithelial cell apoptosis by regulating miR-421/caspase-3 axis in age-related cataract.

    Science.gov (United States)

    Li, Guoxing; Song, Huiyang; Chen, Lei; Yang, Weihua; Nan, Kaihui; Lu, Peirong

    2017-07-01

    Age-related cataract is among the most common chronic disorders of ageing and the apoptosis of lens epithelial cells contributes to non-congenital cataract development. We amid to explore the role of TUG1 and miR-421 in the age-related cataract. The expression level of TUG1, miR-421 and caspase-3 were detected by RT-qPCR. The apoptotic-related protein, caspase-3, Bax and blc-2 were analyzed by western blot. We performed ultraviolet (UV) irradiation to induce SAR01/04 cell apoptosis which was analyzed by flow cytometry. RIP pull-down and luciferase reporter assay were used to verified the combination and regulating among TUG1, miR-421 and caspase-3. Here, we observed that the expression level of TUG1 and caspase-3 in the anterior lens capsules of age-related cataract were significantly higher and miR-421 was significantly lower than that in the normal anterior lens capsules. The apoptosis-related protein, caspase-3, Bax and blc-2 were abnormal expression in the anterior lens capsules of age-related cataract tissue. Our data showed that the expression level of TUG1 and caspase-3 and cell apoptosis rate in SAR01/04 cells treated with UV irradiation was remarkably higher than that in the control. TUG1 negatively regulated miR-421 expression and promoted UV irradiation-induced SAR01/04 cell apoptosis. However, miR-421 inhibitor and pcDNA-caspase-3 could reverse the action of the SRA01/04 cell apoptosis by si-TUG1, which suggested TUG1 promoted UV irradiation-induced apoptosis through downregulating miR-421 expression. Furthermore, this study confirmed TUG1 could been in combination with miR-421, and TUG1 and caspase-3 were both a directly target of miR-421. TUG1 modulated lens epithelial cell apoptosis through miR-421/caspase-3 axis. These findings will offer a novel insight into the pathogenesis of cataract. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Goat's eye integrated with a human cataractous lens: A training model for phacoemulsification.

    Science.gov (United States)

    Sengupta, Sabyasachi; Dhanapal, Praveen; Nath, Manas; Haripriya, Aravind; Venkatesh, Rengaraj

    2015-03-01

    A relatively simple and inexpensive technique to train surgeons in phacoemulsification using a goat's eye integrated with a human cataractous nucleus is described. The goat's eye is placed on a bed of cotton within the lumen of a cylindrical container. This is then mounted on a rectangular thermocol so that the limbus is presented at the surgical field. After making a clear corneal entry with a keratome, the trainer makes a 5-5.5 mm continuous curvilinear capsulorhexis in the anterior lens capsule, creates a crater of adequate depth in the cortex and inserts the human nucleus within this crater in the goat's capsular bag. The surgical wound is sutured, and the goat's eye is ready for training. Creating the capsulorhexis with precision and making the crater of adequate depth to snugly accommodate the human nucleus are the most important steps to prevent excessive wobbling of the nucleus while training.

  8. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory...

  9. Polydopamine-coated capsules

    Energy Technology Data Exchange (ETDEWEB)

    White, Scott R.; Sottos, Nancy R.; Kang, Sen; Baginska, Marta B.

    2018-04-17

    One aspect of the invention is a polymer material comprising a capsule coated with PDA. In certain embodiments, the capsule encapsulates a functional agent. The encapsulated functional agent may be an indicating agent, healing agent, protecting agent, pharmaceutical drug, food additive, or a combination thereof.

  10. The clinical outcomes of surgical management of anterior chamber migration of a dexamethasone implant (Ozurdex®).

    Science.gov (United States)

    Kang, Hyunseung; Lee, Min Woo; Byeon, Suk Ho; Koh, Hyoung Jun; Lee, Sung Chul; Kim, Min

    2017-09-01

    Our purpose was to describe the clinical course, and individualized management approaches, of patients with migration of a dexamethasone implant into the anterior chamber. This was a retrospective review of four patients with seven episodes of anterior chamber migration of a dexamethasone implant. After 924 intravitreal dexamethasone injections, anterior migration of the implant occurred in four eyes of four patients (0.43%). All four eyes were pseudophakic: one eye had a posterior chamber intraocular lens in the capsular bag but in a post-laser posterior capsulotomy state, two eyes had a sulcus intraocular lens (IOL), and one eye had an iris-fixated retropupillary IOL. All eyes had a prior vitrectomy and no lens capsule. The time interval from injection to detection of the implant migration ranged from 2 to 6 weeks. Of the four eyes with corneal edema, only one eye required a corneal transplantation, although it was unclear whether the implant migration was the direct cause of the corneal decompensation because the patient had a history of bullous keratopathy resulting from an extended history of uveitis. All patients underwent surgical intervention: two patients with a repositioning procedure, and the other two patients with removal due to repeated episodes, although surgical removal was not always necessary to reverse the corneal complications. In our study, not all patients required surgical removal of the implants. Repositioning the implant back into the vitreous cavity may be considered as an option in cases involving the first episode with no significant corneal endothelial decompensation. Considering potential anterior segment complications and the loss of drug effectiveness together, an individualized approach is recommended to obtain the best treatment outcomes and to minimize the risk of corneal complications.

  11. Iris-claw intraocular lenses to correct aphakia in the absence of capsule support.

    Science.gov (United States)

    De Silva, Samantha R; Arun, Kikkeri; Anandan, Maghizh; Glover, Nicholas; Patel, Chetan K; Rosen, Paul

    2011-09-01

    To evaluate the indications, postoperative visual efficacy, and complication rate after intraocular implantation of an iris-claw aphakic intraocular lens (IOL). Oxford Eye Hospital, Oxford, United Kingdom. Case series. This chart review comprised eyes with no capsule support that had anterior iris-fixation IOL implantation for aphakia between 2001 and 2009. The study comprised 116 eyes (104 patients). Iris-claw IOLs were inserted during primary lens surgery in 18 eyes (15.5%), during an IOL exchange procedure for dislocated posterior chamber IOLs in 19 eyes (16.4%), and as a secondary procedure in 79 eyes (68.1%). The mean follow-up was 22.4 months (range 3 to 79 months). The final corrected distance visual acuity (CDVA) was 6/12 or better in 68.9% of all eyes and in 47 of 53 eyes (88.7%) with no preoperative comorbidity. Complications included wound leak requiring resuturing in 2.6% of eyes, postoperative intraocular pressure rise in 9.5% of eyes (glaucoma escalation 0.8%), and cystoid macular edema in 7.7% of eyes (0.8% chronic). Iris-claw IOL subluxation occurred in 6.0% of eyes from 5 days to 60 months postoperatively; all the IOLs were repositioned. Corneal decompensation occurred in 1.7% of eyes; 0.8% had retinal detachments. Iris-claw IOL implantation for aphakia gave a good visual outcome and can be used for a wide range of indications. Postoperative complication rates were comparable to, if not better than, those with conventional anterior chamber IOLs. Correct implantation technique is critical in avoiding postoperative IOL subluxation. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Upregulations of Clcn3 and P-Gp Provoked by Lens Osmotic Expansion in Rat Galactosemic Cataract

    Directory of Open Access Journals (Sweden)

    Lixia Ji

    2017-01-01

    Full Text Available Objective. Lens osmotic expansion, provoked by overactivated aldose reductase (AR, is the most essential event of sugar cataract. Chloride channel 3 (Clcn3 is a volume-sensitive channel, mainly participating in the regulation of cell fundamental volume, and P-glycoprotein (P-gp acts as its modulator. We aim to study whether P-gp and Clcn3 are involved in lens osmotic expansion of galactosemic cataract. Methods and Results. In vitro, lens epithelial cells (LECs were primarily cultured in gradient galactose medium (10–60 mM, more and more vacuoles appeared in LEC cytoplasm, and mRNA and protein levels of AR, P-gp, and Clcn3 were synchronously upregulated along with the increase of galactose concentration. In vivo, we focused on the early stage of rat galactosemic cataract, amount of vacuoles arose from equatorial area and scattered to the whole anterior capsule of lenses from the 3rd day to the 9th day, and mRNA and protein levels of P-gp and Clcn3 reached the peak around the 9th or 12th day. Conclusion. Galactosemia caused the osmotic stress in lenses; it also markedly leads to the upregulations of AR, P-gp, and Clcn3 in LECs, together resulting in obvious osmotic expansion in vitro and in vivo.

  13. Advances in pediatric gastroenterology: introducing video camera capsule endoscopy.

    Science.gov (United States)

    Siaw, Emmanuel O

    2006-04-01

    The video camera capsule endoscope is a gastrointestinal endoscope approved by the U.S. Food and Drug Administration in 2001 for use in diagnosing gastrointestinal disorders in adults. In 2003, the agency approved the device for use in children ages 10 and older, and the endoscope is currently in use at Arkansas Children's Hospital. A capsule camera, lens, battery, transmitter and antenna together record images of the small intestine as the endoscope makes its way through the bowel. The instrument is used with minimal risk to the patient while offering a high degree of accuracy in diagnosing small intestine disorders.

  14. Egg capsules of the dusky catshark Bythaelurus canescens (Carcharhiniformes, Scyliorhinidae) from the south-eastern Pacific Ocean.

    Science.gov (United States)

    Concha, F; Bustamante, C; Oddone, M C; Hernández, S; Lamilla, J

    2010-09-01

    The external morphology of the egg capsule of Bythaelurus canescens and its fixation to the substratum are described. Bythaelurus canescens egg capsules are typically vase-shaped, dorso-ventrally flattened, pale yellow in colour when fresh and covered by 12-15 longitudinal ridges. The anterior border of the capsule is straight, whereas the posterior border is semicircular. Two horns bearing long, coiled tendrils arise from the anterior and posterior ends of the capsule. The presence of longitudinal ridges and long coiled tendrils at both anterior and posterior ends of the capsule readily distinguish these egg capsules from those of other chondrichthyans occurring in the south-east Pacific Ocean. © 2010 The Authors. Journal compilation © 2010 The Fisheries Society of the British Isles.

  15. Wireless capsule endoscopy

    Science.gov (United States)

    Iddan, Gavriel; Meron, Gavriel; Glukhovsky, Arkady; Swain, Paul

    2000-05-01

    We have developed a new type of endoscopy, which for the first time allows painless endoscopic imaging of the whole of the small bowel. This procedure involves a wireless capsule endoscope and we describe here its successful testing in humans.

  16. Regulation of the Two Delta Crystallin Genes during Lens Development in the Chicken Embryo

    Science.gov (United States)

    1991-08-22

    lens grows , the mitotical- ly active anterior epithelial cells move towards the equator of the lens from the fringe of the epithelium. As they pass...sequence derived from poliovirus RNA. Nature 334: 320-325. Philpott, G. W., Coulombre, A. J. Lens development. (1965). The differentiation of

  17. Posterior chamber lens implantation with scleral fixation in children with traumatic cataract.

    Science.gov (United States)

    Caca, Ihsan; Sahin, Alparslan; Ari, Seyhmus; Alakus, Fuat

    2011-01-01

    To evaluate the outcomes of posterior chamber lens implantation with scleral fixation (SF-PCIOL) in children with traumatic cataract. Twenty-four eyes of 24 cases were included. All patients had corneal or corneoscleral lacerations that were primarily repaired. Traumatic cataract subsequently developed and SF-PCIOL was performed due to insufficient posterior capsule support. The average age of the patients was 5.8 years (range: 4 to 10 years). All cases had SF-PCIOL implanted via internal route using triangular double scleral flaps made of 9-0 polypropylene after a complete anterior vitrectomy. Average follow-up was 14.6 ± 4.3 months (range: 11 to 18 months). Visual acuity was increased at the last visit in 23 (96%) patients. Common postoperative complications were fibrinous reaction in 6 (25%) patients, transient intraocular pressure increase in 4 (17%) patients, membrane formation requiring removal in 1 (4%) patient, transient intraocular hemorrhage as vitreous hemorrhage in 1 (4%) patient, and retinal detachment in 1 (4%) patient after the postoperative second month. SF-PCIOL is an effective and reliable method in patients with pediatric traumatic cataract who had insufficient posterior capsule support. Copyright 2011, SLACK Incorporated.

  18. Cionni ring and in-the-bag intraocular lens implantation for subluxated lenses: a prospective case series.

    Science.gov (United States)

    Vasavada, Abhay R; Praveen, Mamidipudi R; Vasavada, Viraj A; Yeh, Ru-Yin; Srivastava, Samaresh; Koul, Archana; Trivedi, Rupal H

    2012-06-01

    To report the intraoperative performance and postoperative outcomes of the Cionni-modified capsule tension ring (CTR) implantation in eyes with subluxated lenses. Prospective, observational case series. This study was carried out at Iladevi Cataract & IOL Research Centre, Ahmedabad, India. The study population comprised 41 eyes with subluxated lenses that underwent lens extraction, capsular bag fixation with modified CTR, and in-the-bag single-piece AcrySof intraocular lens (IOL) implantation. Main outcome measures were intraoperative performance and postoperative best-corrected visual acuity (BCVA), IOL centration, and complications. The mean age was 29.46 ± 16.16 years (3-68 years). Mean extent of subluxation was 6.1 ± 1.0 clock hours. Preoperatively, vitreous was detected in the anterior chambers of 5 eyes (12.2%). Two-port anterior chamber vitrectomy was performed in 2 eyes. Mean follow-up was 45.8 ± 2.9 months. Mean preoperative BCVA was 0.66 ± 0.22 logMAR (35 eyes). Mean postoperative BCVA at final follow-up was 0.33 ± 0.21 logMAR (41 eyes) (P IOL decentration was noted and repositioning was required in 2 eyes. Posterior capsule opacification developed in 14 eyes (34.2%); 12 eyes (29.3%) required Nd:YAG capsulotomy. Other complications included cystoid macular edema in 1 eye (2.4%), posterior synechiae in 1 eye (2.4%), and retinal detachment in 1 eye (2.4%). In-the-bag implantation of a Cionni-modified CTR with IOL appears to be a safe option in eyes with subluxated cataract, ensuring a stable IOL with few complications. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Primary culture and growth characteristics of four different species of lens epithelial cells

    Directory of Open Access Journals (Sweden)

    Li-Xia Ji

    2015-07-01

    Full Text Available AIM: To explore the primary culture conditions for four kinds of lens epithelial cells(LECsof rat, rabbit, dog, and human, and measure their growth characteristics. METHODS: The lens capsule or anterior capsular tissue of rat, rabbit, dog and patient were removed by different methods, and they were cut into tiny pieces for primary culture by modified tissue adherent method. The morphological features of four kinds of LECs were observed under an inverted microscope.RESULTS: Four kinds of LECs of rat, rabbit, dog and human could be cultured primarily by tissue adherent method. With the evolution of tissue source, the adherent capacity of LECs gradually strengthened, cells form were changed from irregular polygon to oval, nucleus rounded and cytoplasm enriched gradually. Four kinds of LECs had fibrotic changes after several passages.CONCLUSION: LECs of rat, rabbit, dog and human can be primarily cultured. This method lays the foundation for the mechanism research of caratact and related fields on the cellular and molecular levels.

  20. The mechanical properties of the human hip capsule ligaments.

    Science.gov (United States)

    Hewitt, John D; Glisson, Richard R; Guilak, Farshid; Vail, T Parker

    2002-01-01

    The human hip capsule is adapted to facilitate upright posture, joint stability, and ambulation, yet it routinely is excised in hip surgery without a full understanding of its mechanical contributions. The objective of this study was to provide information about the mechanical properties of the ligaments that form the hip capsule. Cadaver bone-ligament-bone specimens of the iliofemoral, ischiofemoral, and femoral arcuate ligaments were tested to failure in tension. The hip capsule was found to be an inhomogeneous structure and should be recognized as being composed of discrete constituent ligaments. The anterior ligaments, consisting of the 2 arms of the iliofemoral ligament, were much stronger than the posterior ischiofemoral ligament, withstanding greater force at failure and exhibiting greater stiffness. Knowledge of the anatomy and mechanical properties of the capsule may help the hip surgeon choose an appropriate surgical approach or repair strategy.

  1. Microscope-Integrated Intraoperative Ultrahigh-Speed Swept-Source Optical Coherence Tomography for Widefield Retinal and Anterior Segment Imaging.

    Science.gov (United States)

    Lu, Chen D; Waheed, Nadia K; Witkin, Andre; Baumal, Caroline R; Liu, Jonathan J; Potsaid, Benjamin; Joseph, Anthony; Jayaraman, Vijaysekhar; Cable, Alex; Chan, Kinpui; Duker, Jay S; Fujimoto, James G

    2018-02-01

    To demonstrate the feasibility of retinal and anterior segment intraoperative widefield imaging using an ultrahigh-speed, swept-source optical coherence tomography (SS-OCT) surgical microscope attachment. A prototype post-objective SS-OCT using a 1,050-nm wavelength, 400 kHz A-scan rate, vertical cavity surface-emitting laser (VCSEL) light source was integrated to a commercial ophthalmic surgical microscope after the objective. Each widefield OCT data set was acquired in 3 seconds (1,000 × 1,000 A-scans, 12 × 12 mm 2 for retina and 10 × 10 mm 2 for anterior segment). Intraoperative SS-OCT was performed in 20 eyes of 20 patients. In six of seven membrane peels and five of seven rhegmatogenous retinal detachment repair surgeries, widefield retinal imaging enabled evaluation pre- and postoperatively. In all seven cataract cases, anterior imaging evaluated the integrity of the posterior lens capsule. Ultrahigh-speed SS-OCT enables widefield intraoperative viewing in the posterior and anterior eye. Widefield imaging visualizes ocular structures and pathology without requiring OCT realignment. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:94-102.]. Copyright 2018, SLACK Incorporated.

  2. [Phacoemulsification of subluxated lens with capsular tension ring implantation].

    Science.gov (United States)

    Dorecka, Mariola; Rokicki, Wojciech; Nita, Malgorzata; Krysik, Katarzyna; Nita, Ewa; Sikorska, Aleksandra; Romaniuk, Wanda

    2007-01-01

    To evaluate long term results of phacoemulsification with PC IOL and capsular tension ring (CTR) implantation in lens subluxation. The study comprised of 134 patients--146 eyes with subluxated lens. In all cases phacoemulsification with PC IOL and CTR implantation was performed. No intaroperative complications has occured. Postoperative complications included: inflammation in the anterior chamber in 3 eyes (2.1%), retinal detachment in 2 eyes (1.4%). In all cases there was no PC IOL decentration. (1) CTR facilitates phacoemulsification with PC IOL implantation in lens subluxation. (2) Phacoemulsification of subluxated lens with PC IOL and CTR implantation seems to be safe and effective procedure.

  3. Advances in Capsule Endoscopy

    Science.gov (United States)

    Scott, Ryan

    2015-01-01

    Wireless video capsule endoscopy (VCE) is a minimally invasive technology that has revolutionized the approach to small intestinal disease investigation and management. Designed primarily to provide diagnostic imaging of the small intestine, VCE is used predominantly for obscure gastrointestinal bleeding and suspected Crohn’s disease; however, numerous other indications have been established, including the assessment of celiac disease, investigation of small bowel tumors, and surveillance of hereditary polyposis syndromes. Since the introduction of small bowel VCE in 2000, more than 1600 articles have been published describing the evolution of this technology. The main adverse outcome is capsule retention, which can potentially be avoided by careful patient selection or by using a patency capsule. Despite the numerous advances in the past 15 years, limitations such as incomplete VCE studies, missed lesions, and time-consuming reporting remain. The inability to control capsule movement for the application of targeted therapy or the acquisition of tissue for histologic analysis remains among the greatest challenges in the further development of capsule technology. This article outlines the recent technological and clinical advances in VCE and the future directions of research in this field. PMID:27482183

  4. The murine lens: A model to investigate in vivo epithelial-mesenchymal transition.

    Science.gov (United States)

    Shirai, Kumi; Tanaka, Sai-Ichi; Lovicu, Frank J; Saika, Shizuya

    2018-03-01

    Epithelial-mesenchymal transition (EMT) produces myofibroblasts that contribute to the formation of fibrotic tissue with an impairment of tissue homeostasis and functionality. The crystalline lens of the eye is a unique transparent and isolated tissue. The lens vesicle becomes isolated from the surface ectoderm, its cells are all contained as they line the inner surface of the lens capsule. Clinically the formation of fibrotic tissue by the lens epithelial cells causes a type of cataract or opacification and contraction of the lens capsule postcataract surgery. Production of EMT in the intact animal lens by using specific gene transfer to the lens or experimental lens injury has been shown to be a powerful tool to investigate EMT processes. It is not easy to uncover whether the origin of the myofibroblast is epithelial cell-derived or from other cell lineages in fibrotic tissues. However, myofibroblasts that appear in the crystalline lens pathology are totally derived from the lens epithelial cells for the reasons mentioned above. Here, we report on different animal models of lens EMT, using either transgenic approaches or injury to study the biological aspects of EMT. Developmental Dynamics 247:340-345, 2018. © 2017 The Authors Developmental Dynamics published by Wiley Periodicals, Inc. on behalf of American Association of Anatomists. © 2017 The Authors Developmental Dynamics published by Wiley Periodicals, Inc. on behalf of American Association of Anatomists.

  5. Contact lens in keratoconus

    Directory of Open Access Journals (Sweden)

    Varsha M Rathi

    2013-01-01

    Full Text Available Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP lenses, soft and soft toric lenses, piggy back contact lenses (PBCL, hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL.

  6. Contact lens in keratoconus

    Science.gov (United States)

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL. PMID:23925325

  7. NIF capsule performance modeling

    Directory of Open Access Journals (Sweden)

    Weber S.

    2013-11-01

    Full Text Available Post-shot modeling of NIF capsule implosions was performed in order to validate our physical and numerical models. Cryogenic layered target implosions and experiments with surrogate targets produce an abundance of capsule performance data including implosion velocity, remaining ablator mass, times of peak x-ray and neutron emission, core image size, core symmetry, neutron yield, and x-ray spectra. We have attempted to match the integrated data set with capsule-only simulations by adjusting the drive and other physics parameters within expected uncertainties. The simulations include interface roughness, time-dependent symmetry, and a model of mix. We were able to match many of the measured performance parameters for a selection of shots.

  8. Hollow Microporous Organic Capsules

    Science.gov (United States)

    Li, Buyi; Yang, Xinjia; Xia, Lingling; Majeed, Muhammad Irfan; Tan, Bien

    2013-01-01

    Fabrication of hollow microporous organic capsules (HMOCs) could be very useful because of their hollow and porous morphology, which combines the advantages of both microporous organic polymers and non-porous nanocapsules. They can be used as storage materials or reaction chambers while supplying the necessary path for the design of controlled uptake/release systems. Herein, the synthesis of HMOCs with high surface area through facile emulsion polymerization and hypercrosslinking reactions, is described. Due to their tailored porous structure, these capsules possessed high drug loading efficiency, zero-order drug release kinetics and are also demonstrated to be used as nanoscale reactors for the prepareation of nanoparticles (NPs) without any external stabilizer. Moreover, owing to their intrinsic biocompatibility and fluorescence, these capsules exhibit promising prospect for biomedical applications. PMID:23820511

  9. The posterior segment of the temporomandibular joint capsule and its anatomic relationship.

    Science.gov (United States)

    Mérida-Velasco, J Ramón; Rodríguez, J Francisco; de la Cuadra, Crótida; Peces, M Dolores; Mérida, J Antonio; Sánchez, Indalecio

    2007-01-01

    The aim of this work was to clarify the arrangement of the posterior segment of the temporomandibular joint capsule and its pertinent relationships. The temporomandibular region was dissected bilaterally in 20 adult cadavers. Natural stained latex was injected into 16 cadavers through the external carotid artery to facilitate the dissection of the arterial vessels. The posterior segment of the joint capsule is made up of the so-called "bilaminar zone" of the articular disc. The upper internal portion of the posterior segment of the capsule was reinforced by the discomalleolar ligament. The retroarticular space was filled with loose connective tissue and the anterior branches of the anterior tympanic artery were distributed throughout the posterior segment of the joint capsule. The posterior segment of the temporomandibular joint capsule corresponds to the bilaminar zone of the articular disc. The structures of the retroarticular space are extracapsular.

  10. Acid phosphatase and lipid peroxidation in human cataractous lens epithelium

    Directory of Open Access Journals (Sweden)

    Vasavada Abhay

    1993-01-01

    Full Text Available The anterior lens epithelial cells undergo a variety of degenerative and proliferative changes during cataract formation. Acid phosphatase is primarily responsible for tissue regeneration and tissue repair. The lipid hydroperoxides that are obtained by lipid peroxidation of polysaturated or unsaturated fatty acids bring about deterioration of biological membranes at cellular and tissue levels. Acid phosphatase and lipid peroxidation activities were studied on the lens epithelial cells of nuclear cataract, posterior subcapsular cataract, mature cataract, and mixed cataract. Of these, mature cataractous lens epithelium showed maximum activity for acid phosphatase (516.83 moles of p-nitrophenol released/g lens epithelium and maximum levels of lipid peroxidation (86.29 O.D./min/g lens epithelium. In contrast, mixed cataractous lens epithelium showed minimum activity of acid phosphatase (222.61 moles of p-nitrophenol released/g lens epithelium and minimum levels of lipid peroxidation (54.23 O.D./min/g lens epithelium. From our study, we correlated the maximum activity of acid phosphatase in mature cataractous lens epithelium with the increased areas of superimposed cells associated with the formation of mature cataract. Likewise, the maximum levels of lipid peroxidation in mature cataractous lens epithelium was correlated with increased permeability of the plasma membrane. Conversely, the minimum levels of lipid peroxidation in mixed cataractous lens epithelium makes us presume that factors other than lipid peroxidation may also account for the formation of mixed type of cataract.

  11. Gelatin capsule in stomach (image)

    Science.gov (United States)

    ... detect the presence of intestinal parasites. A weighted gelatin capsule attached to a string is swallowed and left in place. After about 4 hours, the gelatin capsule is pulled out of the stomach by ...

  12. Clinical observation of small-incision extracapsular cataract extraction with intraocular lens implantation for the treatment of cataract in the sight restoration project

    Directory of Open Access Journals (Sweden)

    Xiao-Jian Cheng

    2014-04-01

    Full Text Available AIM: To analyze the clinical effects of small-incision extracapsular cataract extraction with intraocular lens implantation for the treatment of cataract.METHODS:Totally 642 cases 676 eyes of cataract were treated by small-incision extracapsular cataract extraction with intraocular lens implantation. Complication during and after operations and postoperative visual acuity was observed.RESULTS:Visual acuity of 670 eyes was ≥0.05 and off-blindness rate was 99.11%, and there was 627 eyes ≥0.3 and the off-disability rate was 92.75% after 1mo. Rupture of posterior capsule during surgery occurred in 24 eyes. Fifty-four eyes were corneal edema, and anterior chamber exudation were 26 eyes, and 23 eyes were hypertension after operation. CONCLUSION: There are a little complications during and after operation for cataract treated by small-incision extracapsular cataract extraction with intraocular lens implantation. Patients have good recovery after operation. This operation does not need high-standard equipments and is suitable in the sight restoration project.

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... lens because they can be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, ... Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals Harmful to Eyes ...

  14. Management of adhesive capsulitis

    Directory of Open Access Journals (Sweden)

    Stupay KL

    2015-08-01

    Full Text Available Kristen L Stupay,1 Andrew S Neviaser2 1Tulane University School of Medicine, New Orleans, LA, USA; 2George Washington University Medical Faculty Associates, Washington, DC, USA Abstract: Adhesive capsulitis of the shoulder is a condition of capsular contracture that reduces both active and passive glenohumeral motion. The cause of adhesive capsulitis is not known but it is strongly associated with endocrine abnormalities such as diabetes. Diverse terminology and the absence of definitive criteria for diagnosis make evaluating treatment modalities difficult. Many treatment methods have been reported, most with some success, but few have been proved to alter the natural course of this disease. Most afflicted patients will achieve acceptable shoulder function without surgery. Those who remain debilitated after 8–12 months are reasonable candidates for invasive treatments. Here, the various treatment methods and the data to support their use are reviewed. Keywords: frozen shoulder, stiff shoulder, periarthritis, painful shoulder 

  15. Atraumatic Anterior Dislocation of the Hip Joint

    Directory of Open Access Journals (Sweden)

    Tadahiko Ohtsuru

    2015-01-01

    Full Text Available Dislocation of the hip joint in adults is usually caused by high-energy trauma such as road traffic accidents or falls from heights. Posterior dislocation is observed in most cases. However, atraumatic anterior dislocation of the hip joint is extremely rare. We present a case of atraumatic anterior dislocation of the hip joint that was induced by an activity of daily living. The possible causes of this dislocation were anterior capsule insufficiency due to developmental dysplasia of the hip, posterior pelvic tilt following thoracolumbar kyphosis due to vertebral fracture, and acetabular anterior coverage changes by postural factor. Acetabular anterior coverage changes in the sagittal plane were measured using a tomosynthesis imaging system. This system was useful for elucidation of the dislocation mechanism in the present case.

  16. Downregulation of Smac attenuates H2O2-induced apoptosis via endoplasmic reticulum stress in human lens epithelial cells.

    Science.gov (United States)

    De-Qian, Kong; Yue, Liu; Li, Li; Guangying, Zheng

    2017-07-01

    Second mitochondria-derived activator of caspases (Smac) is reported to promote apoptosis. Given the important role of apoptosis in cataract development, the aim of this study was to investigate whether Smac induces human lens epithelial cell (HLEC) apoptosis via endoplasmic reticulum stress (ERS). Smac expression was examined by immunohistochemistry in anterior lens capsules from 157 patients with age-related cataracts and 5 normal controls. The role of Smac in hydrogen peroxide (H2O2)-induced ERS and apoptosis was further evaluated using small interfering RNA knockdown in an HLEC line. Notably, Smac expression was significantly higher in patients with cataracts than in controls, but showed no association with cataract severity. Cell survival was inversely correlated with H2O2 concentration, and was most significantly affected at 200 μmol/L. Moreover, flow cytometry revealed that Smac knockdown attenuated H2O2-induced apoptosis and enhanced apoptotic- and endoplasmic reticulum-related marker expression-including that of glucose-regulated protein 78, C/EBP homologous protein, caspase 3, B-cell chronic lymphocytic leukemia/lymphoma 2-associated X, and BCL2-at the gene and protein level. Collectively, these results indicate that Smac plays an important role in ERS-induced apoptosis in HLECs, suggesting its close association with cataract development.

  17. Septic lens implantation syndrome in a cat.

    Science.gov (United States)

    Dalesandro, Nicole; Stiles, Jean; Miller, Margaret

    2011-09-01

    A 13-year-old female spayed domestic shorthair cat was presented initially for a change in the appearance of the left eye. On initial examination, a small penetrating wound was suspected as the cause for a corneal scar, an anterior cortical incipient cataract and mild iritis. The cat was not re-presented until 1 year later at which time ocular pain was marked. Severe anterior uveitis and glaucoma were diagnosed and the eye enucleated. Histopathology documented intralenticular coccoid bacteria and septic lens implantation syndrome. © 2011 American College of Veterinary Ophthalmologists.

  18. Adhesive capsulitis of the shoulder.

    Science.gov (United States)

    Neviaser, Andrew S; Neviaser, Robert J

    2011-09-01

    Adhesive capsulitis is characterized by painful, gradual loss of active and passive shoulder motion resulting from fibrosis and contracture of the joint capsule. Other shoulder pathology can produce a similar clinical picture, however, and must be considered. Management is based on the underlying cause of pain and stiffness, and determination of the etiology is essential. Subtle clues in the history and physical examination can help differentiate adhesive capsulitis from other conditions that cause a stiff, painful shoulder. The natural history of adhesive capsulitis is a matter of controversy. Management of true capsular restriction of motion (ie, true adhesive capsulitis) begins with gentle, progressive stretching exercises. Most patients improve with nonsurgical treatment. Indications for surgery should be individualized. Failure to obtain symptomatic improvement and continued functional disability following ≥6 months of physical therapy is a general guideline for surgical intervention. Diligent postoperative therapy to maintain motion is required to minimize recurrence of adhesive capsulitis.

  19. Arthroscopic treatment of refractory adhesive capsulitis of the shoulder.

    Science.gov (United States)

    Fernandes, Marcos Rassi

    2014-01-01

    to evaluate the results of arthroscopic treatment of refractory adhesive capsulitis of the shoulder associated as for improved range of motion after a minimum follow up of six years. from August 2002 to December 2004, ten patients with adhesive capsulitis of the shoulder resistant to conservative treatment underwent arthroscopic surgery. One interscalene catheter was placed for postoperative analgesia before the procedure. All were in Phase II, with a minimum follow up of two years. The mean age was 52.9 years (39-66), predominantly female (90%), six on the left shoulder. The time between onset of symptoms and surgical treatment ranged from six to 20 months. Four adhesive capsulitis were found to be primary (40%) and six secondary (60%). the preoperative mean of active anterior elevation was 92°, of external rotation was 10.5° of the L5 level internal rotation; the postoperative ones were 149°, 40° and T12 level, respectively. Therefore, the average gain was 57° for the anterior elevation, 29.5° for external rotation in six spinous processes. There was a significant difference in movements' gains between the pre and post-operative periods (padhesive capsulitis of the shoulder resistant to conservative treatment, improving the range of joint movements of patients evaluated after a minimum follow up of six years.

  20. Patient acceptability of the Tecnis® multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Sood P

    2011-03-01

    Full Text Available Priyanka Sood1, Maria A Woodward21Emory Eye Center, Atlanta, GA, USA; 2Kellogg Eye Center, Ann Arbor, MI, USAAbstract: Cataract surgery has evolved. The goal of the surgeon includes both restoration of vision and refinement of vision. Patients' desire for spectacle independence has driven the market for presbyopia-correcting cataract surgery and development of novel intraocular lens (IOL designs. The Tecnis® Multifocal Intraocular Lens incorporates an aspheric, modified anterior prolate IOL with a diffractive multifocal lens design. The design aims to minimize spherical aberration and improve range of focus. The purpose of this review is to assess patient acceptability of the Tecnis® multifocal intraocular lens.Keywords: Tecnis®, intraocular lens, multifocal, presbyopia 

  1. Surgical effect of traumatic lens dislocation with secondary glaucoma

    Directory of Open Access Journals (Sweden)

    Xiao-Dan Zhang

    2014-10-01

    Full Text Available AIM: To retrospectively evaluate the effect of lens extraction combined with vitrectomy to treat traumatic lens dislocation with secondary glaucoma.METHODS:Thirty-one eyes(31 casesof lens dislocation caused by blunt trauma with secondary glaucoma were treated respectively with cataract extraction combined with anterior vitrectomy, trabeculectomy and intraocular lens implantation. The visual acuity and pressure were observed 1wk, 1 and 3mo after operative. RESULTS:Thirty-one eyes were all complete the operation successfully, and 6 eyes were given combined trabeculectomy, 9 eyes were implanted anterior chamber intraocular lens implantation(IOLand 15 eyes were given posterior chamber suture fixation. Sixteen eyes were implanted in one-stage operation, while 8 eyes were implanted in two-stage operation. All intraocular pressure(IOPwere controlled to the normal level after operation and 23 eyes had visual acuity of more than 0.3.CONCLUSION:Lens extraction combined with vitrectomy is an effective method for treatment of lens dislocation with secondary glaucoma. In order to control the IOP and get well visual function, we should choose IOL implantation or trabeculectomy according to the patient's condition.

  2. The effect of myofibroblasts and corticosteroid injections in adhesive capsulitis.

    Science.gov (United States)

    Hettrich, Carolyn M; DiCarlo, Edward F; Faryniarz, Deborah; Vadasdi, Katherine B; Williams, Riley; Hannafin, Jo A

    2016-08-01

    Adhesive capsulitis is a condition that results in restricted glenohumeral motion. Fibroblasts have been implicated in the disease process; however, their role as a contractile element in the development of fibrosis and capsular contracture is not well understood. We hypothesized (1) that myofibroblast prevalence in capsular biopsy specimens from patients with adhesive capsulitis would be increased compared with controls and (2) that patients treated with an intra-articular injection of corticosteroid would have fewer myofibroblasts. The study prospectively enrolled 20 consecutive patients with adhesive capsulitis scheduled for capsular release and matched controls. Tissue samples were collected from the posterior and anterior capsule for histomorphologic and immunohistologic analyses. Identical sectioning and preparation was performed in 14 additional adhesive capsulitis specimens from patients who had not received corticosteroid injections. Patients with adhesive capsulitis not treated with preoperative corticosteroid demonstrated more histologic evidence of fibromatosis, synovial hyperplasia, and an increase in positive staining for α-smooth muscle actin than patients who had received intra-articular injections of steroid. No specimens obtained from control patients demonstrated positive staining for α-smooth muscle actin. There was a higher prevalence of myofibroblast staining in patients with adhesive capsulitis, implicating activation of the myofibroblast in the pathophysiology of capsular contracture. Intra-articular steroid injection decreases the presence and amount of fibromatosis, vascular hyperplasia, fibrosis, and the presence of fibroblasts staining for α-smooth muscle actin. This supports the use of steroid injections to alter the disease process by decreasing the pathologic changes found in the capsular tissue. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. Wireless capsule endo bronchoscopy

    Directory of Open Access Journals (Sweden)

    Baratz DM

    2014-03-01

    Full Text Available No abstract available. Article truncated at 150 words. Case Presentation History of Present Illness A 67 year-old man presents 10 days after swallowing a capsule endoscopy camera that was never retrieved. The wireless capsule was swallowed asymptomatically for evaluation of heme positive stools after negative upper and lower endoscopies. Patient noted that the evening after swallowing the camera he developed mild shortness of breath and cough. The cough and shortness of breath were persistent and worsened while lying down and when moving positions. He denied prior issues with swallowing or aspiration. Review of Systems Negative other than what is noted above. PMH, SH, and FH Past medical history: coronary artery disease, peripheral vascular disease, hyperlipidemia Surgical history: femoral-popliteal bypass, previous shoulder and back surgery Social history: 1 pack/day of cigarettes for 50 years, prior alcohol usage but not current, no illicit drugs Family history: no pulmonary diseases Physical Exam Vital signs: temperature 36.7º C, heart rate 86 beats per minute ...

  4. REFRACTIVE NEUTRON LENS

    OpenAIRE

    Petrov, P. V.; Kolchevsky, N. N.

    2013-01-01

    Compound concave refractive lenses are used for focusing neutron beam. Investigations of spectral and focusing properties of a refractive neutron lens are presented. Resolution of the imaging system on the base of refractive neutron lenses depends on material properties and parameters of neutron source. Model of refractive neutron lens are proposed. Results of calculation diffraction resolution and focal depth of refractive neutron lens are discussed.

  5. Contact lens in keratoconus

    OpenAIRE

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the En...

  6. Development of capsule assembling apparatus

    International Nuclear Information System (INIS)

    Tayama, Yoshinobu; Kanazawa, Yoshiharu; Sozawa, Shizuo; Kawamata, Kazuo; Shizuoka, Yoshihiro; Onizawa, Satoshi; Nakagawa, Tetsuya

    2012-01-01

    The service of JMTR hot laboratory, associated with the Japan Materials Testing Reactor, was started on 1971 to examine specimens irradiated mainly in the JMTR. A wide variety of post irradiation examinations for research and development of nuclear fuels and materials are available in the JMTR hot laboratory. This laboratory has an advantage that its hot cell is connected with JMTR by a canal directly, and it is easy to transport irradiated capsule and specimens. New power ramping test for the high burn-up fuels by using the JMTR has been planed. The power ramping test using a boiling water capsule facility needs a re-capsuling of fuel rods for re-irradiation, and a modification of the facility up to about 100 GWD/t were necessary. This report introduces the new handling techniques and capsule assembling apparatus for the boiling water capsule facility. (author)

  7. Corneo-scleral limbal changes following short-term soft contact lens wear.

    Science.gov (United States)

    Consejo, Alejandra; Bartuzel, Maciej M; Iskander, D Robert

    2017-10-01

    To assess whether short-term soft contact lens wear alters the anterior eye surface. Twenty-two neophyte subjects wore soft contact lenses for a period of five hours. Topography based corneo-scleral limbal radius estimates were derived from height measurements acquired with a corneo-scleral profilometer. Additionally, central corneal thickness (CCT), anterior chamber depth (ACD), corneal curvature radius (R) and white-to-white (WTW) diameter were acquired with an OCT-assisted biometer. Measurements were obtained without lens wear (baseline), immediately after lens removal following five hours of wear and three hours after lens removal. Short-term soft contact lens wear significantly modifies corneo-scleral limbal radius (mean±SD: 130±74μm, p contact lens wear. The increment in the limbal diameter could reach over 0.5mm but that alteration does not correspond to changes in WTW diameter and it was not observable to the examiner using a slit lamp. Assessing topographical limbus after contact lens wear could be a tool to optimize the selection of the contact lens, from the perspective of anterior eye surface changes. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  8. Phacoemulsification with primary implantation of an intraocular lens in patients with uveitis

    Directory of Open Access Journals (Sweden)

    Pålsson S

    2017-08-01

    Full Text Available Sara Pålsson,1,2 Marita Andersson Grönlund,1,2 Dragana Skiljic,1,2 Madeleine Zetterberg1,2 1Department of Clinical Neuroscience/Ophthalmology, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; 2Department of Ophthalmology, Sahlgrenska University Hospital, Mölndal, Sweden Purpose: To evaluate the outcome of cataract surgery in adult patients with uveitis. Materials and methods: In this retrospective cohort study, medical charts of patients with uveitis and matched control patients without uveitis who underwent cataract surgery at the Eye Clinic, Sahlgrenska University Hospital, Mölndal, between January 2005 and December 2009 were analyzed. Results: The study included 58 eyes with and 283 eyes without uveitis. The most common etiologies were idiopathic anterior uveitis and Fuchs’ heterochromic uveitis. Postoperative visual acuity at 4 weeks was ≥0.5 decimal (0.3 logMAR in 48 eyes with uveitis (87.3% compared to 180 non-uveitic eyes (86.1%. Four eyes with uveitis (7.1% and one eye without uveitis (0.5% developed postoperative intraocular hypertension/glaucoma. Posterior capsule opacification developed in 11 eyes (19.0% with and 28 eyes (12.4% without uveitis. Conclusion: With appropriate perioperative anti-inflammatory regimen and surveillance, modern cataract surgery using phacoemulsification and primary intraocular lens implantation can be performed in patients with uveitis without greater risk of complications, yielding similar visual outcome as in patients without uveitis. Keywords: cataract, intraocular lens, phacoemulsification, uveitis

  9. Quantitative measurements in capsule endoscopy.

    Science.gov (United States)

    Keuchel, M; Kurniawan, N; Baltes, P; Bandorski, D; Koulaouzidis, A

    2015-10-01

    This review summarizes several approaches for quantitative measurement in capsule endoscopy. Video capsule endoscopy (VCE) typically provides wireless imaging of small bowel. Currently, a variety of quantitative measurements are implemented in commercially available hardware/software. The majority is proprietary and hence undisclosed algorithms. Measurement of amount of luminal contamination allows calculating scores from whole VCE studies. Other scores express the severity of small bowel lesions in Crohn׳s disease or the degree of villous atrophy in celiac disease. Image processing with numerous algorithms of textural and color feature extraction is further in the research focuses for automated image analysis. These tools aim to select single images with relevant lesions as blood, ulcers, polyps and tumors or to omit images showing only luminal contamination. Analysis of motility pattern, size measurement and determination of capsule localization are additional topics. Non-visual wireless capsules transmitting data acquired with specific sensors from the gastrointestinal (GI) tract are available for clinical routine. This includes pH measurement in the esophagus for the diagnosis of acid gastro-esophageal reflux. A wireless motility capsule provides GI motility analysis on the basis of pH, pressure, and temperature measurement. Electromagnetically tracking of another motility capsule allows visualization of motility. However, measurement of substances by GI capsules is of great interest but still at an early stage of development. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Linguatula serrata in the anterior chamber of the eye

    Directory of Open Access Journals (Sweden)

    Muna Bhende

    2014-01-01

    Full Text Available We report a case of intraocular Linguatula in healthy young female who presented with a history of trivial trauma, dislocated lens, inflammation and secondary glaucoma. A mobile worm was seen in the anterior chamber. Pars plana lensectomy and vitrectomy was planned to remove both the cataractous lens and the parasite during which the worm disappeared from view but was later recovered from the cassette fluid. It was identified as the nymphal form of Linguatula serrata (tongue worm.

  11. Anterior shoulder capsular tears in professional baseball players.

    Science.gov (United States)

    Gulotta, Lawrence V; Lobatto, Daniel; Delos, Demetris; Coleman, Struan H; Altchek, David W

    2014-08-01

    Tearing of the anterior capsule of the shoulder is a rare but debilitating injury for throwing athletes. However, there is very little in the literature to guide its diagnosis and treatment. In this case series, we outline our experience with anterior capsular tears of the shoulder in professional baseball players. Five professional baseball players were diagnosed with midsubstance tears of their anterior capsule. A trial of rest and rehabilitation failed in all patients, and they eventually underwent surgery. These patients were retrospectively reviewed. The presenting symptoms and findings were documented, and outcomes were assessed by the player's ability to return to play. The mean age was 33.5 years (range, 31-37 years), and all patients presented with anterior shoulder pain and the inability to throw. No patient had an acute traumatic injury. Magnetic resonance imaging provided the correct diagnosis in 4 patients, and the diagnosis was made with diagnostic arthroscopy in the fifth. Three underwent arthroscopic repair, and 2 underwent open repair of the anterior capsule. Of the 5 players, 4 (80%) returned to their preinjury level by a mean of 13.3 months (range, 8-18 months). Anterior capsular tears can occur in older throwing athletes. Surgical repair, whether arthroscopic or open, can yield good results in most patients. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  12. Cataract Surgery in Anterior Megalophthalmos: A Review

    Science.gov (United States)

    GALVIS, Virgilio; TELLO, Alejandro; M. RANGEL, Carlos

    2015-01-01

    Anterior megalophthalmos is characterized by megalocornea associated with a very broad anterior chamber and ciliary ring elongation. It is also called X-linked megalocornea. It is accompanied by early development of cataracts, zonular anomalies, and, rarely, vitreoretinal disorders. Subluxation of a cataract can occur in cataract surgery because of zonular weakness. In addition, in most patients, standard intraocular lens (IOL) decentration is a risk because of the enlarged sulcus and capsular bag. These unique circumstances make cataract surgery challenging. To date, several approaches have been developed. Implantation of a retropupillary iris-claw aphakic intraocular lens may be a good option because it is easier than suturing the IOL and can have better and more stable anatomic and visual outcomes, compared to other techniques. PMID:27350950

  13. Capsulitis of the Second Toe

    Science.gov (United States)

    ... arch that is structurally unstable and a tight calf muscle. Symptoms Because capsulitis of the second toe is ... may be prescribed for patients who have tight calf muscles. Shoe modifications. Supportive shoes with stiff soles are ...

  14. Status of irradiation capsule design

    International Nuclear Information System (INIS)

    Nagata, Hiroshi; Yamaura, Takayuki; Nagao, Yoshiharu

    2013-01-01

    For the irradiation test after the restart of JMTR, further precise temperature control and temperature prediction are required. In the design of irradiation capsule, particularly sophisticated irradiation temperature prediction and evaluation are urged. Under such circumstance, among the conventional design techniques of irradiation capsule, the authors reviewed the evaluation method of irradiation temperature. In addition, for the improvement of use convenience, this study examined and improved FINAS/STAR code in order to adopt the new calculation code that enables a variety of analyses. In addition, the study on the common use of the components for radiation capsule enabled the shortening of design period. After the restart, the authors will apply this improved calculation code to the design of irradiation capsule. (A.O.)

  15. MRI diagnosis of reverse and separation of meniscus articular capsule

    International Nuclear Information System (INIS)

    Tang Xiaofeng; Zhou Chengtao; Mu Renqi; Zhang Guanghui; Xu Yongzhong

    2005-01-01

    Objective: To explore the MR imaging of reverse and separation of meniscal articular capsule. Methods: MR imaging of reverse and separation of meniscus articular capsule confirmed by surgery and arthroscope were analyzed retrospectively in 8 cases. Results: The 'Butterfly knot sign' disappeared and was replaced with fluid signal on the sagittal slice of meniscal body in 8 cases. Part of back angle remained in 3 cases. 'Double anterior cruciate ligament sign' was showed on one side of middle sagittal slice in 7 cases. 'Reverse meniscus sign' was revealed in intercondylar fossa on the coronary view in 8 cases. Abnormal high signal was showed in the injured meniscus in 6 cases. Abnormal high signal was detected in the opposite meniscus in 5 cases. Conclusion: The MR findings of reverse and separation of meniscus articular capsule include disappearance of 'butterfly knot sign', appearance of 'reverse meniscus sign' and 'double anterior cruciate ligament sign'. The diagnosis would be established if the former 2 signs were present or all the 3 signs were present simultaneously. (authors)

  16. Adhesive capsulitis: a review.

    Science.gov (United States)

    Ewald, Anthony

    2011-02-15

    Adhesive capsulitis is a common, yet poorly understood, condition causing pain and loss of range of motion in the shoulder. It can occur in isolation or concomitantly with other shoulder conditions (e.g., rotator cuff tendinopathy, bursitis) or diabetes mellitus. It is often self-limited, but can persist for years and may never fully resolve. The diagnosis is usually clinical, although imaging can help rule out other conditions. The differential diagnosis includes acromioclavicular arthropathy, autoimmune disease (e.g., systemic lupus erythematosus, rheumatoid arthritis), biceps tendinopathy, glenohumeral osteoarthritis, neoplasm, rotator cuff tendinopathy or tear (with or without impingement), and subacromial and subdeltoid bursitis. Several treatment options are commonly used, but few have high-level evidence to support them. Because the condition is often self-limited, observation and reassurance may be considered; however, this may not be acceptable to many patients because of the painful and debilitating nature of the condition. Nonsurgical treatments include analgesics (e.g., acetaminophen, nonsteroidal anti-inflammatory drugs), oral prednisone, and intra-articular corticosteroid injections. Home exercise regimens and physical therapy are often prescribed. Surgical treatments include manipulation of the joint under anesthesia and capsular release.

  17. White matter alterations in the internal capsule and psychomotor impairment in melancholic depression.

    Science.gov (United States)

    Hyett, Matthew P; Perry, Alistair; Breakspear, Michael; Wen, Wei; Parker, Gordon B

    2018-01-01

    Emerging evidence suggests that structural brain abnormalities may play a role in the pathophysiology of melancholic depression. We set out to test whether diffusion-derived estimates of white matter structure were disrupted in melancholia in regions underpinning psychomotor function. We hypothesized that those with melancholia (and evidencing impaired psychomotor function) would show disrupted white matter organization in internal capsule subdivisions. Diffusion magnetic resonance imaging (dMRI) data were acquired from 22 melancholic depressed, 23 non-melancholic depressed, and 29 healthy control participants. Voxel-wise fractional anisotropy (FA), radial diffusivity (RD), and axial diffusivity (AD) values were derived for anterior, posterior, and retrolenticular limbs of the internal capsule and compared between groups. Neuropsychological (reaction time) and psychomotor functioning were assessed and correlated against FA. Fractional anisotropy was distinctly increased, whilst RD was decreased, in the right anterior internal capsule in those with melancholia, compared to controls. The right anterior limb of the internal capsule correlated with clinical ratings of psychomotor disturbance, and reduced psychomotor speed was associated with increased FA values in the right retrolenticular limb in those with melancholia. Our findings highlight a distinct disturbance in the local white matter arrangement in specific regions of the internal capsule in melancholia, which in turn is associated with psychomotor dysfunction. This study clarifies the contribution of structural brain integrity to the phenomenology of melancholia, and may assist future efforts seeking to integrate neurobiological markers into depression subtyping.

  18. Anterior internal lenticonus accompanied by congenital nuclear cataract.

    Science.gov (United States)

    Liu, Zhe; Sun, Chuan-Bin; Yao, Ke

    2011-12-01

    Internal lenticonus is a very rare morphologic abnormality of crystalline lens which has been reported in only several cases in the literature. We herein reported the clinical characteristics and surgical findings of the anterior internal lenticonus accompanied by congenital nuclear cataract. Cataract extraction accompanied with intraocular lens implantation was uneventfully performed, and a good visual outcome was achieved in this case. Viral infection during embryonal and fetal period might account for the formation of the anterior internal lenticonus and congenital nuclear cataract in our case.

  19. Spatial pattern of cell geometry and cell-division orientation in zebrafish lens epithelium

    Directory of Open Access Journals (Sweden)

    Toshiaki Mochizuki

    2014-09-01

    Full Text Available Cell proliferation is a key regulator of tissue morphogenesis. We examined cell proliferation and cell division in zebrafish lens epithelium by visualizing cell-cycle phases and nuclear positions, using fluorescent-labeled geminin and histone proteins. Proliferation was low in the anterior region of lens epithelium and higher in the marginal zone anterior to the equator, suggesting that the proliferation zone, called the germinative zone, is formed in zebrafish lens. Interestingly, cell-division orientation was biased longitudinally in the anterior region, shifted from longitudinal to circumferential along the anterior–posterior axis of lens sphere, and was biased circumferentially in the peripheral region. These data suggest that cell-division orientation is spatially regulated in zebrafish lens epithelium. The Hertwig rule indicates that cells tend to divide along their long axes. Orientation of long axes and cell division were biased similarly in zebrafish lens epithelium, suggesting that cell geometry correlates with cell-division orientation. A cell adhesion molecule, E-cadherin, is expressed in lens epithelium. In a zebrafish e-cadherin mutant, the long axes and cell-division orientation were shifted more longitudinally. These data suggest that E-cadherin is required for the spatial pattern of cell geometry and cell-division orientation in zebrafish lens epithelium.

  20. c-Myc regulates cell proliferation during lens development.

    Directory of Open Access Journals (Sweden)

    Gabriel R Cavalheiro

    Full Text Available Myc protooncogenes play important roles in the regulation of cell proliferation, growth, differentiation and survival during development. In various developing organs, c-myc has been shown to control the expression of cell cycle regulators and its misregulated expression is detected in many human tumors. Here, we show that c-myc gene (Myc is highly expressed in developing mouse lens. Targeted deletion of c-myc gene from head surface ectoderm dramatically impaired ocular organogenesis, resulting in severe microphtalmia, defective anterior segment development, formation of a lens stalk and/or aphakia. In particular, lenses lacking c-myc presented thinner epithelial cell layer and growth impairment that was detectable soon after its inactivation. Defective development of c-myc-null lens was not caused by increased cell death of lens progenitor cells. Instead, c-myc loss reduced cell proliferation, what was associated with an ectopic expression of Prox1 and p27(Kip1 proteins within epithelial cells. Interestingly, a sharp decrease in the expression of the forkhead box transcription factor Foxe3 was also observed following c-myc inactivation. These data represent the first description of the physiological roles played by a Myc family member in mouse lens development. Our findings support the conclusion that c-myc regulates the proliferation of lens epithelial cells in vivo and may, directly or indirectly, modulate the expression of classical cell cycle regulators in developing mouse lens.

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... new application of artificial intelligence shows whether a patient’s eyes point to high blood pressure or risk ...

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Costume Contact Lenses Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non-Prescription Contact Lens Laura: Vision ... Robyn: Blurry Vision and Daily Eye Drops After One Use Facts About Colored Contacts and Halloween Safety ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... in a pair of colored contact lenses, Laura Butler of Parkersburg, W.Va., had "extreme pain in ... to wear any kind of contact lens. In Butler's case, the lenses caused an infection and left ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... an impulsive buy from a souvenir shop, but 10 hours after she first put in a pair ... Prescription Contact Lens Laura: Vision Loss After Just 10 Hours Robyn: Blurry Vision and Daily Eye Drops ...

  11. bubble chamber lens

    CERN Multimedia

    Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals Harmful to Eyes Four Ways Over- ... without a prescription are breaking the law, and may be fined $11,000 per violation. "Many of ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... an ophthalmologist — an eye medical doctor — who will measure each eye and talk to you about proper ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. Follow the contact lens care directions for cleaning, disinfecting, and wearing the lenses. Never share contact ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  16. Experimental observation of lens damage after low doses of γ-ray irradiation to rabbit eyes

    International Nuclear Information System (INIS)

    Tang Xicheng; Hu Chunzhi; Wang Huijun; Zeng Aiping

    2000-01-01

    Objective: To investigate and evaluate low dose γ-ray radiation induced lens damage. Methods: Both eyes of each rabbit were exposed to a single dose of 25 or 50 cGy γ-rays in two groups, respectively. Samples were examined by transmission electron microscopy (TEM) and slit lamp microscopy (SLM)after irradiation. Results: Three days after 25 and 50 cGy irradiation,the epithelial cells of lens equator al region showed marked swelling and many vacuoles formed in intercellular space and cytoplasm,and accompanied by increased multi-lamellar bodies. Five months after irradiation, SLM of both groups showed that the posterior sub-capsule cortex exhibited clusters of vacuoles; 11 months after 50 cGy irradiation,the posterior sub-capsule and deep cortex manifested marked cloudy opacities. Conclusion: Low doses of γ-ray (25 and 50 cGy) irradiation can markedly damage lens of rabbits

  17. [Iris hooks and modified capsular tension ring for subluxation lens in patients with Marfan's syndrome].

    Science.gov (United States)

    Wu, Wen-Jie; Zheng, Dan-ying; Zheng, Ying-feng; Cai, Xiao-yu

    2007-02-01

    To evaluate clinical efficiency and safety of the iris hooks and modified capsular tension ring (MCTR) for the treatment of subluxation lens in patients with Marfan's syndrome. This study comprised 5 patients (7 eyes) with Marfan's syndrome and subluxation lens. After 3.2 mm clear cornea incision and continuous curvilinear capsulorhexis (CCC), 2 - 4 disposable nylon iris hooks were inserted through the stab incisions and placed in the capsulorhexis to support the capsule and enlarged the CCC. Following irrigation/aspiration, a MCTR with suture in its eyelet was placed in the capsule bag. After tightening and tying the suture of MCTR, the capsular bag was centered and fixed. A foldable AcrySof one-piece intraocular lens (IOL) was then placed in the capsule bag. Twelve months after the operation, the best corrected visual acuity was >/= 0.8 in six eyes and 0.7 in one eye. The scheimpflug images obtained from the Pentacam demonstrated that the IOL were well centered. UBM showed that all the MCTR and the haptics of the IOL were in the capsule bag, the eyelet of the MCTR was rested stably between the capsulorhexis margin and the iris. The retroillumination photograph indicated that only one eye had obvious posterior capsular opacification. No intraoperative and postoperative complications such as prolapse of vitreous and retina detachment was occurred. The iris hooks can provide excellent intraoperative capsule-lens stability and facilitate the manipulation during operation. MCTR allows additional suture fixation to the eye wall without damaging the capsular bag and maintains the long-term stability of the intraocular lens. Furthermore, MCTR is helpful for avoiding dislocation of the IOL due to progressive weakening of the zonular fibers in some patients and provides long-term safety.

  18. Viscous froth lens

    Science.gov (United States)

    Green, T. E.; Bramley, A.; Lue, L.; Grassia, P.

    2006-11-01

    Microscale models of foam structure traditionally incorporate a balance between bubble pressures and surface tension forces associated with curvature of bubble films. In particular, models for flowing foam microrheology have assumed this balance is maintained under the action of some externally imposed motion. Recently, however, a dynamic model for foam structure has been proposed, the viscous froth model, which balances the net effect of bubble pressures and surface tension to viscous dissipation forces: this permits the description of fast-flowing foam. This contribution examines the behavior of the viscous froth model when applied to a paradigm problem with a particularly simple geometry: namely, a two-dimensional bubble “lens.” The lens consists of a channel partly filled by a bubble (known as the “lens bubble”) which contacts one channel wall. An additional film (known as the “spanning film”) connects to this bubble spanning the distance from the opposite channel wall. This simple structure can be set in motion and deformed out of equilibrium by applying a pressure across the spanning film: a rich dynamical behavior results. Solutions for the lens structure steadily propagating along the channel can be computed by the viscous froth model. Perturbation solutions are obtained in the limit of a lens structure with weak applied pressures, while numerical solutions are available for higher pressures. These steadily propagating solutions suggest that small lenses move faster than large ones, while both small and large lens bubbles are quite resistant to deformation, at least for weak applied back pressures. As the applied back pressure grows, the structure with the small lens bubble remains relatively stiff, while that with the large lens bubble becomes much more compliant. However, with even further increases in the applied back pressure, a critical pressure appears to exist for which the steady-state structure loses stability and unsteady

  19. Lens regeneration in New Zealand albino rabbits after endocapsular cataract extraction.

    Science.gov (United States)

    Gwon, A; Gruber, L; Mantras, C; Cunanan, C

    1993-05-01

    To evaluate the regenerative capacity of the adult rabbit lens after removal of a Concanavalin A-induced posterior subcapsular cataract. Cataractogenesis was induced by intravitreal injection of Concanavalin A in adult New Zealand albino rabbits. At 7 mo postinjection, the cataracts were removed. Endocapsular lens extraction was performed by phacoemulsification and irrigation/aspiration with Balanced Salt Solution. Postoperatively, lens regeneration was first noted in the Balanced Salt Solution normal lens group at 3 weeks and the Concanavalin A cataract group at 6 weeks. By the 3-mo postoperative examination, lens regrowth, measured by digital image analysis, filled 74.5% of the capsule bag in the Balanced Salt Solution normal lens group and 46.6% in the Concanavalin A cataract group. In the latter group, less lens material was regenerated and at a slower rate than in eyes with extraction of a normal lens. This experimental model is the first to show that lens regeneration can occur after removal of cataracts secondary to inflammation.

  20. Arthroscopic treatment of refractory adhesive capsulitis of the shoulder

    Directory of Open Access Journals (Sweden)

    Marcos Rassi Fernandes

    Full Text Available OBJECTIVE: to evaluate the results of arthroscopic treatment of refractory adhesive capsulitis of the shoulder associated as for improved range of motion after a minimum follow up of six years. METHODS: from August 2002 to December 2004, ten patients with adhesive capsulitis of the shoulder resistant to conservative treatment underwent arthroscopic surgery. One interscalene catheter was placed for postoperative analgesia before the procedure. All were in Phase II, with a minimum follow up of two years. The mean age was 52.9 years (39-66, predominantly female (90%, six on the left shoulder. The time between onset of symptoms and surgical treatment ranged from six to 20 months. Four adhesive capsulitis were found to be primary (40% and six secondary (60%. RESULTS: the preoperative mean of active anterior elevation was 92°, of external rotation was 10.5° of the L5 level internal rotation; the postoperative ones were 149°, 40° and T12 level, respectively. Therefore, the average gain was 57° for the anterior elevation, 29.5° for external rotation in six spinous processes. There was a significant difference in movements' gains between the pre and post-operative periods (p<0.001. By the Constant Score (range of motion, there was an increase of 13.8 (average pre to 32 points (average post. CONCLUSION: the arthroscopic treatment proved effective in refractory adhesive capsulitis of the shoulder resistant to conservative treatment, improving the range of joint movements of patients evaluated after a minimum follow up of six years.

  1. Biomechanics of the Hip Capsule and Capsule Management Strategies in Hip Arthroscopy.

    Science.gov (United States)

    Nepple, Jeffrey J; Smith, Matthew V

    2015-12-01

    Recent advances in our understanding of the function of the hip capsule have clarified its importance to normal hip function and kinematics. The iliofemoral ligament is the primary stabilizing structure for controlling anterior translation and external rotation of the hip, and is violated by the arthroscopic interportal capsulotomy. Microinstability of the hip occurring after surgical trauma remains a poorly defined clinical entity. In certain at-risk populations, capsular repair should be considered as part of an arthroscopic hip procedure to achieve optimal outcomes and avoid iatrogenic instability (dislocation or microinstability). Despite a lack of conclusive evidence-based indications, we recommend capsular repair in the settings of borderline hip dysplasia (or dysplastic variants such as increased femoral anteversion), hip hypermobility, connective tissue disorders, and traumatic or atraumatic instability. With careful attention to arthroscopic capsular management, adequate exposure can be achieved and reproducibly allow for an effective capsular repair when indicated.

  2. Radial head button holing: a cause of irreducible anterior radial head dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Su-Mi; Chai, Jee Won; You, Ja Yeon; Park, Jina [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Bae, Kee Jeong [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Orthopedic Surgery, Seoul (Korea, Republic of)

    2016-10-15

    ''Buttonholing'' of the radial head through the anterior joint capsule is a known cause of irreducible anterior radial head dislocation associated with Monteggia injuries in pediatric patients. To the best of our knowledge, no report has described an injury consisting of buttonholing of the radial head through the annular ligament and a simultaneous radial head fracture in an adolescent. In the present case, the radiographic findings were a radial head fracture with anterior dislocation and lack of the anterior fat pad sign. Magnetic resonance imaging (MRI) clearly demonstrated anterior dislocation of the fractured radial head through the torn annular ligament. The anterior joint capsule and proximal portion of the annular ligament were interposed between the radial head and capitellum, preventing closed reduction of the radial head. Familiarity with this condition and imaging findings will aid clinicians to make a proper diagnosis and fast decision to perform an open reduction. (orig.)

  3. Summary Report for Capsule Dry Storage Project

    Energy Technology Data Exchange (ETDEWEB)

    JOSEPHSON, W S

    2003-09-04

    There are 1.936 cesium (Cs) and strontium (Sr) capsules stored in pools at the Waste Encapsulation and Storage Facility (WESF). These capsules will be moved to dry storage on the Hanford Site as an interim measure to reduce risk. The Cs/Sr Capsule Dry Storage Project (CDSP) is conducted under the assumption the capsules will eventually be moved to the repository at Yucca Mountain, and the design criteria include requirements that will facilitate acceptance at the repository. The storage system must also permit retrieval of capsules in the event vitrification of the capsule contents is pursued. A cut away drawing of a typical cesium chloride (CsCI) capsule and the capsule property and geometry information are provided in Figure 1.1. Strontium fluoride (SrF{sub 2}) capsules are similar in design to CsCl capsules. Further details of capsule design, current state, and reference information are given later in this report and its references. Capsule production and life history is covered in WMP-16938, Capsule Characterization Report for Capsule Dry Storage Project, and is briefly summarized in Section 5.2 of this report.

  4. Modeling Corneal Oxygen with Scleral Gas Permeable Lens Wear.

    Science.gov (United States)

    Compañ, Vicente; Aguilella-Arzo, Marcel; Edrington, Timothy B; Weissman, Barry A

    2016-11-01

    The main goal of this current work is to use an updated calculation paradigm, and updated boundary conditions, to provide theoretical guidelines to assist the clinician whose goal is to improve his or her scleral gas permeable (GP) contact lens wearing patients' anterior corneal oxygen supply. Our model uses a variable value of corneal oxygen consumption developed through Monod equations that disallows negative oxygen tensions within the stroma to predict oxygen tension at the anterior corneal surface of scleral GP contact lens wearing eyes, and to describe oxygen tension and flux profiles, for various boundary conditions, through the lens, tears, and cornea. We use several updated tissue and boundary parameters in our model. Tear exchange with GP scleral lenses is considered nonexistent in this model. The majority of current scleral GP contact lenses should produce some levels of corneal hypoxia under open eye conditions. Only lenses producing the thinnest of tear vaults should result in anterior corneal surface oxygen tensions greater than a presumed critical oxygen tension of 100 mmHg. We also find that corneal oxygen tension and flux are each more sensitive to modification in tear vault than to changes in lens oxygen permeability, within the ranges of current clinical manipulation. Our study suggests that clinicians would be prudent to prescribe scleral GP lenses manufactured from higher oxygen permeability materials and especially to fit without excessive corneal clearance.

  5. Predicting scleral GP lens entrapped tear layer oxygen tensions.

    Science.gov (United States)

    Jaynes, Jared M; Edrington, Timothy B; Weissman, Barry A

    2015-02-01

    Over the past decade, utilization of scleral gas permeable (GP) contact lenses has steadily increased. Scleral GP lenses offer yet another option for patients suffering from visually debilitating corneal and tear conditions. Oxygen delivery to the cornea in the presence of a contact lens system continues to be a subject of interest, and scleral GP lenses are no exception. This paper utilizes an existing model based on simultaneous two lens systems (piggyback lenses) as a resistance to oxygen in series, and applies this model to scleral GP lens systems. Theoretical oxygen tensions are calculated for tear layers trapped beneath scleral contact lens systems and the anterior corneal surface with a simple single chamber corneal model using a computer software spreadsheet. Only the best case scenario for current scleral gas permeable lenses (thickness and Dk)/tear layer values allow sufficient tear layer oxygen tension (approximately 100 mmHg) to preclude corneal hypoxia. The results of the spreadsheet model suggest that clinicians would be prudent to prescribe scleral GP lenses manufactured in the highest Dk materials available and to fit without excessive corneal clearance to minimize anterior segment hypoxia. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  6. Pigment dispersion syndrome associated with spontaneous subluxation of crystalline lens

    Directory of Open Access Journals (Sweden)

    Vikas Veerwal

    2017-01-01

    Full Text Available Pigment dispersion syndrome (PDS is an ocular condition characterized by a dispersion of iris pigment throughout the eye. This pigment is deposited in a characteristic manner on the corneal endothelium as Krukenberg's spindle, anterior surface of the iris, in the trabecular meshwork, on the lens and zonule and occasionally on the anterior hyaloid face. Even with deposition of pigment on zonular fibers, no zonular weakness, or zonular dehiscence has been reported in these cases. We report a unique case of PDS with bilateral spontaneous subluxation of crystalline lens. With characteristic findings of pigment distribution in both his eyes, the patient had concave iris configuration with heavily pigmented trabecular meshwork confirming the diagnosis of PDS. The patient had bilateral 180° temporal subluxation of crystalline lens in both his eyes. The usual cause of lens subluxation such as Marfan's Syndrome and Ehler's Danlos Syndrome was ruled out. The patient underwent right eye followed by left eye intracapsular cataract extraction with ab-interno technique with postoperative best-corrected visual acuity (BCVA of 6/9 in both eyes. Spontaneous subluxation of crystalline lens in isolated PDS is not known to occur and has been reported by means of this case. We recommend a thorough assessment of zonular status in all cases of PDS.

  7. Stress Analysis of Cyrano Capsule Hanger

    International Nuclear Information System (INIS)

    Hasibuan, Djaruddin

    2000-01-01

    Base on the requirement criteria on nuclear installation, and to complete the document of the cyrano capsule facility the analysis of the cyrano capsule hanger has been done. The cyrano capsule hanger by the overhang installation on the main support of fixed bridge is a main support of whole of the cyrano capsule and frame. By using W 4 x 13 shave as main hanger of cyrano capsule, the maximum allowable stress was found to be bigger than the actual stress. From the final analysis it can be concluded that the hanger of the cyrano capsule is in safe condition

  8. Endurance test for DUPIC capsule

    International Nuclear Information System (INIS)

    Chung, Heung June; Bae, K. K.; Lee, C. Y.; Park, J. M.; Ryu, J. S.

    1999-07-01

    This report presents the pressure drop, vibration and endurance test results for mini-plate fuel rig which were designed fabricately by KAERI. From the pressure drop test results, it is noted that the flow rate across the capsule corresponding to the pressure drop of 200 kPa is measured to be about 9.632 kg/sec. Vibration frequency for the capsule ranges from 14 to 18.5 Hz. RMS (Root Mean Square) displacement for the fuel rig is less than 14 μm, and the maximum displacement is less than 54 μm. Based on the endurance test results, the appreciable fretting wear for the DUPIC capsule was not detected. Oxidation on the support tube is observed, also tiny trace of wear between contact points observed. (author). 4 refs., 10 tabs., 45 figs

  9. Morphological changes in the conjunctiva, episclera and sclera following short-term miniscleral contact lens wear in rigid lens neophytes.

    Science.gov (United States)

    Alonso-Caneiro, David; Vincent, Stephen J; Collins, Michael J

    2016-02-01

    To quantify the influence of short-term wear of miniscleral contact lenses on the morphology of the corneo-scleral limbus, the conjunctiva, episclera and sclera. OCT images of the anterior eye were captured before, immediately following 3h of wear and then 3h after removal of a miniscleral contact lens for 10 young (27 ± 5 years) healthy participants (neophyte rigid lens wearers). The region of analysis encompassed 1mm anterior, to 3.5mm posterior to the scleral spur. Natural diurnal variations in thickness were measured on a separate day and compensated for in subsequent analyses. Following 3h of lens wear, statistically significant tissue thinning was observed across all quadrants, with a mean decrease in thickness of -24.1 ± 3.6 μm (pscleral spur (-48.2 ± 5.7 μm), corresponding to the approximate edge of the lens landing zone. Compression of the conjunctiva/episclera accounted for about 70% of the changes. Optimal fitting miniscleral contact lenses worn for three hours resulted in significant tissue compression in young healthy eyes, with the greatest thinning observed superiorly, potentially due to the additional force of the eyelid, with a partial recovery of compression 3h after lens removal. Most of the morphological changes occur in the conjunctiva/episclera layers. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Triggered Release from Polymer Capsules

    Energy Technology Data Exchange (ETDEWEB)

    Esser-Kahn, Aaron P. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Odom, Susan A. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Sottos, Nancy R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Materials Science and Engineering; White, Scott R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Aerospace Engineering; Moore, Jeffrey S. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry

    2011-07-06

    Stimuli-responsive capsules are of interest in drug delivery, fragrance release, food preservation, and self-healing materials. Many methods are used to trigger the release of encapsulated contents. Here we highlight mechanisms for the controlled release of encapsulated cargo that utilize chemical reactions occurring in solid polymeric shell walls. Triggering mechanisms responsible for covalent bond cleavage that result in the release of capsule contents include chemical, biological, light, thermal, magnetic, and electrical stimuli. We present methods for encapsulation and release, triggering methods, and mechanisms and conclude with our opinions on interesting obstacles for chemically induced activation with relevance for controlled release.

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Vision Ophthalmology Job Center Our Sites EyeWiki International Society of Refractive Surgery Subspecialties Cataract/Anterior Segment Comprehensive ... Vision Ophthalmology Job Center Our Sites EyeWiki International Society of Refractive Surgery Subspecialties Cataract/Anterior Segment Comprehensive ...

  12. Citation parameters of contact lens-related articles published in the ophthalmic literature.

    Science.gov (United States)

    Cardona, Genís; Sanz, Joan P

    2014-09-01

    This study aimed at exploring the citation parameters of contact lenses articles published in the Ophthalmology thematic category of the Journal Citation Reports (JCR). The Thompson Reuters Web of Science database was accessed to record bibliometric information and citation parameters of all journals listed under the Ophthalmology area of the 2011 JCR edition, including the journals with main publication interests in the contact lens field. In addition, the same database was used to unveil all contact lens-related articles published in 2011 in the same thematic area, whereupon differences in citation parameters between those articles published in contact lens and non-contact lens-related journals were explored. Significant differences in some bibliometric indicators such as half-life and overall citation count were found between contact lens-related journals (shorter half-life and fewer citations) and the median values for the Ophthalmology thematic area of the JCR. Visual examination of all Ophthalmology journals uncovered a total of 156 contact lens-related articles, published in 28 different journals, with 27 articles each for Contact Lens & Anterior Eye, Eye & Contact Lens, and Optometry and Vision Science. Significant differences in citation parameters were encountered between those articles published in contact lens and non-contact lens source journals. These findings, which disclosed contact lenses to be a fertile area of research, may be of interest to researchers and institutions. Differences in bibliometric indicators are of relevance to avoid unwanted bias when conducting between- and within-discipline comparisons of articles, journals, and researchers.

  13. Osmotic buckling of spherical capsules.

    Science.gov (United States)

    Knoche, Sebastian; Kierfeld, Jan

    2014-11-07

    We study the buckling of elastic spherical shells under osmotic pressure with the osmolyte concentration of the exterior solution as a control parameter. We compare our results for the bifurcation behavior with results for buckling under mechanical pressure control, that is, with an empty capsule interior. We find striking differences for the buckling states between osmotic and mechanical buckling. Mechanical pressure control always leads to fully collapsed states with opposite sides in contact, whereas uncollapsed states with a single finite dimple are generic for osmotic pressure control. For sufficiently large interior osmolyte concentrations, osmotic pressure control is qualitatively similar to buckling under volume control with the volume prescribed by the osmolyte concentrations inside and outside the shell. We present a quantitative theory which also captures the influence of shell elasticity on the relationship between osmotic pressure and volume. These findings are relevant for the control of buckled shapes in applications. We show how the osmolyte concentration can be used to control the volume of buckled shells. An accurate analytical formula is derived for the relationship between the osmotic pressure, the elastic moduli and the volume of buckled capsules. This also allows use of elastic capsules as osmotic pressure sensors or deduction of elastic properties and the internal osmolyte concentration from shape changes in response to osmotic pressure changes. We apply our findings to published experimental data on polyelectrolyte capsules.

  14. Photon Production Within Storage Capsules

    CERN Document Server

    Rittmann, P D

    2003-01-01

    This report provides tables and electronic worksheets that list the photon production rate within SrF2 and CsC1 storage capsules, particularly the continuous spectrum of bremsstrahlung photons from the slowing down of the emitted electrons (BREMCALC).

  15. Sensor capsule for diagnosis of gastric disorders

    Science.gov (United States)

    Holen, J. T.

    1972-01-01

    Motility and pH sensor capsule is developed to monitor gastric acidity, pressure, and temperature. Capsule does not interfere with digestion. Sensor is capsule which includes pH electrode, Pitran pressure transducer, and thermistor temperature sensor all potted in epoxy and enclosed in high density polyethylene sheath.

  16. A catoptric lens

    International Nuclear Information System (INIS)

    Rambauske, W.R.

    1973-01-01

    The invention relates to a catoptric lens for combining energies transmitted by several sources such as lasers; said lens comprising mirrors, the reflective surfaces of which have their focuses spaced from a common axis of symmetry. By means of these reflecting surfaces, which are generated by the nutation of portions of quadratic conics about the axis of symmetry, it is possible to focus the energy emmited by several lasers at the focus of the exit-mirror reflecting surface. This can be applied to thermonuclear fusion [fr

  17. Anterior Horn Cell Diseases

    Directory of Open Access Journals (Sweden)

    Merve Firinciogullari

    2016-09-01

    Full Text Available The anterior horn cells control all voluntary movement. Motor activity, respiratory, speech, and swallowing functions are dependent upon signals from the anterior horn cells. Diseases that damage the anterior horn cells, therefore, have a profound impact. Symptoms of anterior horn cell loss (weakness, falling, choking lead patients to seek medical attention. In this article, anterior horn diseases were reviewed, diagnostic criteria and management were discussed in detail. [Archives Medical Review Journal 2016; 25(3.000: 269-303

  18. Dose conversion coefficients for neutron exposure to the lens of the human eye

    International Nuclear Information System (INIS)

    Manger, Ryan P.; Bellamy, Michael B.; Eckerman, Keith F.

    2011-01-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10 -9 to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations.

  19. Dose conversion coefficients for neutron exposure to the lens of the human eye

    International Nuclear Information System (INIS)

    Manger, R. P.; Bellamy, M. B.; Eckerman, K. F.

    2012-01-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10 -9 to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations. (authors)

  20. Probing cell internalisation mechanics with polymer capsules.

    Science.gov (United States)

    Chen, Xi; Cui, Jiwei; Ping, Yuan; Suma, Tomoya; Cavalieri, Francesca; Besford, Quinn A; Chen, George; Braunger, Julia A; Caruso, Frank

    2016-10-06

    We report polymer capsule-based probes for quantifying the pressure exerted by cells during capsule internalisation (P in ). Poly(methacrylic acid) (PMA) capsules with tuneable mechanical properties were fabricated through layer-by-layer assembly. The P in was quantified by correlating the cell-induced deformation with the ex situ osmotically induced deformation of the polymer capsules. Ultimately, we found that human monocyte-derived macrophage THP-1 cells exerted up to approximately 360 kPa on the capsules during internalisation.

  1. Quadrupole magnetic lens

    International Nuclear Information System (INIS)

    Piskunov, V.A.

    1981-01-01

    The following connection of windings of electromagnet is suggested for simplification of the design of qUadrupole magnetic lens intended for use in radiotechnical and electron-optical devices. The mentioned windings are connected with each other by a bridge scheme and the variable resistors are switched in its diagonals in the lens containing four electromagnet with windings connected with two variable resistors the mobile contacts of which are connected with a direct current source. Current redistribution between left windings and right windings takes place at shift of mobile contact of variable resistor, and current redistribution between upper and low coils of electromagnets takes place at shifting mobile contact of the other variable resistor. In this case smooth and independent electron-optical misalignment of lens by two mutually perpendicular directions proceeds. Use of the given design of the lens in the oscillograph permits to use printing assembly for alignment plate and to reduce the number of connections at the expense of decreasing the number of resistors

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if you have perfect vision, you need to get an eye exam and a prescription ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ...

  4. MISSING: BUBBLE CHAMBER LENS

    CERN Multimedia

    2001-01-01

    Would the person who borrowed the large bubble chamber lens from the Microcosm workshops on the ISR please return it. This is a much used piece from our object archives. If anybody has any information about the whereabouts of this object, please contact Emma.Sanders@cern.ch Thank you

  5. The Lens of Chemistry

    Science.gov (United States)

    Thalos, Mariam

    2013-01-01

    Chemistry possesses a distinctive theoretical lens--a distinctive set of theoretical concerns regarding the dynamics and transformations of a perplexing variety of organic and nonorganic substances--to which it must be faithful. Even if it is true that chemical facts bear a special (reductive) relationship to physical facts, nonetheless it will…

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her with a corneal ... A recent article from U.S. News and World Report explains what ophthalmologists are and how they can ...

  7. bubble chamber lens

    CERN Multimedia

    Was used in a PS experiment. Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  8. Thermal Lens Microscope

    Science.gov (United States)

    Uchiyama, Kenji; Hibara, Akihide; Kimura, Hiroko; Sawada, Tsuguo; Kitamori, Takehiko

    2000-09-01

    We developed a novel laser microscope based on the thermal lens effect induced by a coaxial beam comprised of excitation and probe beams. The signal generation mechanism was confirmed to be an authentic thermal lens effect from the measurement of signal and phase dependences on optical configurations between the sample and the probe beam focus, and therefore, the thermal lens effect theory could be applied. Two-point spatial resolution was determined by the spot size of the excitation beam, not by the thermal diffusion length. Sensitivity was quite high, and the detection ability, evaluated using a submicron microparticle containing dye molecules, was 0.8 zmol/μm2, hence a distribution image of trace chemical species could be obtained quantitatively. In addition, analytes are not restricted to fluorescent species, therefore, the thermal lens microscope is a promising analytical microscope. A two-dimensional image of a histamine molecule distribution, which was produced in mast cells at the femtomole level in a human nasal mucous polyp, was obtained.

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... an Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact ... After One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter ...

  10. Central vault in dry eye patients successfully wearing scleral lens.

    Science.gov (United States)

    Sonsino, Jeffrey; Mathe, Dora Sztipanovits

    2013-09-01

    Scleral contact lenses are used to treat symptoms of severe dry eyes. Procedures for fitting scleral lenses have been vague because of lack of standardized guidelines. This retrospective case series sought to establish average vault over central cornea in successful scleral lens wearers with dry eyes. Anterior segment optical coherence tomography was used to measure the distance between the posterior lens surface and cornea in 20 eyes of 12 consecutive patients successfully fit in the Vanderbilt Scleral Lens Clinic. Mean vault was 380 ± 110 μm. There was no correlation between vault and corneal curvature or vault and visual acuity. With a large SD in average vault, precision in central vault does not seem to be important in scleral contact lenses for successful fit for dry eyes.

  11. Clinical survey of lens care in contact lens patients.

    Science.gov (United States)

    Ky, W; Scherick, K; Stenson, S

    1998-10-01

    Overall, contact lenses provide a safe and effective modality for vision correction. However, problems do occasionally arise. Up to 80% of contact lens complications can be traced to poor patient compliance with recommended lens care guidelines. We conducted a survey to evaluate the level of patient compliance in specific areas of lens care and maintenance and to assess patient knowledge of basic contact lens information. Patients were asked to complete an anonymous 15 question survey that focused on lens care--specifically the use of contact lens cleaners, methods of disinfection, enzyme treatments, use of rewetting drops, and the frequency of follow-up exams. In addition, the survey included six true/false questions relating to contact lens care and safety. There were a total of 103 participants in the study. Approximately 24% of patients stated they never cleaned their lenses prior to disinfection, and 5% used saline solutions as their primary mode of disinfection. A sizable portion of those surveyed (43% of soft lens wearers and 71% of rigid gas permeable lens wearers) either never used enzyme cleaners or used them less than once a month. Seventy percent of patients either never used rewetting drops or used them less than once a day. Twenty-nine percent of patients consulted their eye care professionals every 2 years and 6% less often than every two years. Six questions assessed patient knowledge of contact lens care safety. Of a possible six out of six correct answers, the mean number of correct responses was 3.74. A sizable proportion of contact lens wearers do not adequately adhere to recommended contact lens care, and many have an inadequate understanding of contact lens care guidelines. Therefore, it is important that practitioners place more emphasis on patient education at the time of initial contact lens fitting and reinforce such instruction during follow-up visits.

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available Subspecialties Cataract/Anterior Segment Comprehensive Ophthalmology Cornea/External Disease Glaucoma Neuro-Ophthalmology/Orbit Pediatric Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available Subspecialties Cataract/Anterior Segment Comprehensive Ophthalmology Cornea/External Disease Glaucoma Neuro-Ophthalmology/Orbit Pediatric Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus On ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Center Global Ophthalmology Guide Find an Ophthalmologist Advanced Search Annual Meeting Clinical Education Practice Management Member Services ... Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ... Subspecialties Cataract/Anterior Segment Comprehensive Ophthalmology Cornea/External ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced Search Annual Meeting Clinical Education Practice Management Member ... Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ... Subspecialties Cataract/Anterior Segment Comprehensive Ophthalmology Cornea/ ...

  16. Bilateral spontaneous dislocation of posterior chamber intraocular lens in a patient with gyrate atrophy

    Directory of Open Access Journals (Sweden)

    Michael Kinori

    2012-01-01

    Full Text Available We report a patient with gyrate atrophy, a rare metabolic disease, who had bilateral late spontaneous posterior dislocation of in-the-bag posterior chamber intraocular lens (PCIOL. He underwent pars plana vitrectomy, PCIOL retrieval and anterior chamber intraocular lens implantation in both eyes. This report may imply that patients with gyrate atrophy are at risk for spontaneous dislocation of intraocular lenses.

  17. Quantitative Analysis of Lens Nuclear Density Using Optical Coherence Tomography (OCT with a Liquid Optics Interface: Correlation between OCT Images and LOCS III Grading

    Directory of Open Access Journals (Sweden)

    You Na Kim

    2016-01-01

    Full Text Available Purpose. To quantify whole lens and nuclear lens densities using anterior-segment optical coherence tomography (OCT with a liquid optics interface and evaluate their correlation with Lens Opacities Classification System III (LOCS III lens grading and corrected distance visual acuity (BCVA. Methods. OCT images of the whole lens and lens nucleus of eyes with age-related nuclear cataract were analyzed using ImageJ software. The lens grade and nuclear density were represented in pixel intensity units (PIU and correlations between PIU, BCVA, and LOCS III were assessed. Results. Forty-seven eyes were analyzed. The mean whole lens and lens nuclear densities were 26.99 ± 5.23 and 19.43 ± 6.15 PIU, respectively. A positive linear correlation was observed between lens opacities (R2 = 0.187, p<0.01 and nuclear density (R2 = 0.316, p<0.01 obtained from OCT images and LOCS III. Preoperative BCVA and LOCS III were also positively correlated (R2 = 0.454, p<0.01. Conclusions. Whole lens and lens nuclear densities obtained from OCT correlated with LOCS III. Nuclear density showed a higher positive correlation with LOCS III than whole lens density. OCT with a liquid optics interface is a potential quantitative method for lens grading and can aid in monitoring and managing age-related cataracts.

  18. DIABETES AND SHOULDER ADHESIVE CAPSULITIS

    OpenAIRE

    J. Mohanakrishnan; Bhanumathy Mohanakrishnan

    2016-01-01

    Background: Adhesive capsulitis (AC) of shoulder is a common condition encountered by physical therapists in their routine outpatient care services; AC of shoulder is as by itself being a self limiting disorder lasts from months to years causing pain and discomfort to the patients. The condition is commonly associated with Diabetes mellitus or other co morbidities. The incidence of AC is high among diabetic individuals and it becomes mandatory on the part of physical therapists and other heal...

  19. Contraindications for video capsule endoscopy

    OpenAIRE

    Bandorski, Dirk; Kurniawan, Niehls; Baltes, Peter; Hoeltgen, Reinhard; Hecker, Matthias; Stunder, Dominik; Keuchel, Martin

    2016-01-01

    Video capsule endoscopy (VCE) has been applied in the last 15 years in an increasing field of applications. Although many contraindications have been put into perspective, some precautions still have to be considered. Known stenosis of the gastrointestinal tract is a clear contraindication for VCE unless surgery is already scheduled or at least has been considered as an optional treatment modality. In patients with a higher incidence of stenosis, as in an established diagnosis of Crohn?s dise...

  20. A case of Alagille syndrome complicated by intraocular lens subluxation and rhegmatogenous retinal detachment

    Science.gov (United States)

    Fukumoto, Masanori; Ikeda, Tsunehiko; Sugiyama, Tetsuya; Ueki, Mari; Sato, Takaki; Ishizaki, Eisuke

    2013-01-01

    This case report describes a case of Alagille syndrome with developing intraocular lens subluxation and rhegmatogenous retinal detachment 4 years after cataract surgery. A 15-year-old female patient with Alagille syndrome-associated cataracts in both eyes underwent phacoemulsification aspiration and intraocular lens implantation. Four years postoperative, intraocular lens subluxation developed in her left eye. For treatment, extraction of the dislocated intraocular lens, anterior vitrectomy, and intraocular lens fixation was performed. Three weeks later, the patient developed rhegmatogenous retinal detachment, which was well-treated by pars plana vitrectomy. Cataract surgery needs to be performed carefully in patients with Alagille syndrome due to the weakness of the zonule of Zinn. Careful postoperative observation is necessary for patients with Alagille syndrome who have undergone intraocular surgery in order to facilitate early detection of a possible rhegmatogenous retinal detachment. PMID:23898221

  1. Application of Anterior Segment Optical Coherence Tomography in Pediatric Ophthalmology

    Directory of Open Access Journals (Sweden)

    Ricardo Salles Cauduro

    2012-01-01

    Full Text Available Purpose. Application of anterior segment optical coherence (AS-OCT in pediatric ophthalmology. Methods. Retrospective clinical study case series of 26 eyes of 19 pediatric patients throughout a 21-month period, presenting anterior segment pathologies, were submitted to AS-OCT examination (OCT Visante, 1310 nm, Zeiss, noncontact technique, no sedation requirement. Results. AS-OCT images were obtained from 19 patients (range: 2 months to 12 years. Clinical diagnosis of anterior segment abnormalities included cornea disease (n=7, congenital anterior segment conditions (n=10, ocular trauma (n=1, anterior segment surgeries (n=2, iridocorneal angle abnormalities (n=4, intermediate uveitis (n=2. The most common OCT findings were corneal hyperreflectivity and thickening (n=15, shallow anterior chamber with iris-lens diaphragm anterior displacement (n=4, atypical corneal curvature (n=4, corneal thinning (n=4, peripheral synechiae with angle closure (n=3, increased anterior chamber depth (n=2, and proximal portion of glaucoma drainage tube (n=2. Conclusion. In the present study, noncontact AS-OCT demonstrated to be a feasible technique to evaluate the anterior segment providing anatomic details and useful to clarify diagnosis in the pediatric population.

  2. [Correct contact lens hygiene].

    Science.gov (United States)

    Blümle, S; Kaercher, T; Khaireddin, R

    2013-06-01

    Although contact lenses have long been established in ophthalmology, practical aspects of handling contact lenses is becoming increasingly less important in the clinical training as specialist for ophthalmology. Simultaneously, for many reasons injuries due to wearing contact lenses are increasing. In order to correct this discrepancy, information on contact lenses and practical experience with them must be substantially increased from a medical perspective. This review article deals with the most important aspects for prevention of complications, i.e. contact lens hygiene.

  3. Prolonging contact lens wear and making contact lens wear safer.

    Science.gov (United States)

    Foulks, Gary N

    2006-02-01

    To summarize the present status of safety and efficacy of contact lens wear. Literature review. Ovid Medline searches were performed on records from 1966 through 2005 using keywords: keratitis, contact lens complications, extended-wear contact lenses, and silicone-hydrogel contact lenses. Patients desire comfort, clarity of vision, and prolonged contact lens wear when contact lenses are used to correct refractive error. Practitioners desire patient satisfaction but also require maintenance of the integrity of the eye and no complications that jeopardize vision or health of the eye. Improvements in the oxygen permeability of the contact lens materials, design of the contact lens and its surface, and solutions for the maintenance of the lens have reduced but not eliminated the risks of infection, inflammation, and conjunctival papillary reaction associated with contact lens wear. The lessons of past and recent history suggest that patient education and practitioner participation in the management of contact lens wear continue to be critical factors for patient satisfaction and safety in the extended wear of contact lenses. The availability of highly oxygen permeable contact lenses has increased the tolerance and safety of extended contact lens wear, but patient instruction and education in proper use and care of lenses is required and caution is advised.

  4. Aspherical Lens Design Using Genetic Algorithm for Reducing Aberrations in Multifocal Artificial Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Chih-Ta Yen

    2015-09-01

    Full Text Available A complex intraocular lens (IOL design involving numerous uncertain variables is proposed. We integrated a genetic algorithm (GA with the commercial optical design software of (CODE V to design a multifocal IOL for the human eye. We mainly used an aspherical lens in the initial state to the crystalline type; therefore, we used the internal human eye model in the software. The proposed optimized algorithm employs a GA method for optimally simulating the focusing function of the human eye; in this method, the thickness and curvature of the anterior lens and the posterior part of the IOL were varied. A comparison of the proposed GA-designed IOLs and those designed using a CODE V built-in optimal algorithm for 550 degrees myopia and 175 degrees astigmatism conditions of the human eye for pupil size 6 mm showed that the proposed IOL design improved the spot size of root mean square (RMS, tangential coma (TCO and modulation transfer function (MTF at a spatial frequency of 30 with a pupil size of 6 mm by approximately 17%, 43% and 35%, respectively. However, the worst performance of spherical aberration (SA was lower than 46%, because the optical design involves a tradeoff between all aberrations. Compared with the traditional CODE V built-in optimal scheme, the proposed IOL design can efficiently improve the critical parameters, namely TCO, RMS, and MTF.

  5. Capsule Endoscopy: A Single Centre Experience with the First 226 Capsules

    Directory of Open Access Journals (Sweden)

    R Enns

    2004-01-01

    Full Text Available BACKGROUND: Capsule endoscopy (CE refers to a novel diagnostic method of imaging the gastrointestinal tract using a wireless capsule that transmits images to a data recorder while the device traverses the small intestine.

  6. Diagnostic and therapeutic radio pharmaceutical capsules

    International Nuclear Information System (INIS)

    Haney, T.A.; Wedeking, P.W.; Morcos, N.A.

    1981-01-01

    An improved pharmaceutical radioactive capsule consisting of a non-toxic, water soluble material adapted to being ingested and rapidly disintegrating on contact with fluids of the gastro-intestinal tract is described. Each capsule is provided with filler material supporting a pharmaceutically useful radioactive compound absorbable from the gastro-intestinal tract. The capsule is preferably of gelatin, methyl cellulose or polyvinyl alcohol and the filler is a polyethylene glycol. The radioactive compound may be iodine e.g. sodium radioiodide I-131 or 123. The capsule may also contain a reducing agent e.g. sodium thiosulphate, sulphite, or bisulphite. (author)

  7. Challenges and Future of Wireless Capsule Endoscopy.

    Science.gov (United States)

    Saurin, Jean-Christophe; Beneche, Nicolas; Chambon, Christine; Pioche, Mathieu

    2016-01-01

    In 2015, capsule endoscopy was introduced as the main investigation method for small bowel mucosal diseases, and its role in colonic diseases has been gradually revealed. Future challenges for capsule endoscopy, besides improvements of image quality and visualization of each part of the small bowel and colonic mucosa, include the development of gastric capsules, the capacity to perform histological examination of the mucosa, and maybe in the future, some capsule endoscopy-driven therapeutics. The aim of this review was to evaluate the clinical demands and feasibility of achieving the aforementioned objectives.

  8. Critical swelling of fluctuating capsules

    Science.gov (United States)

    Diamant, Haim; Haleva, Emir

    2009-03-01

    In many natural transport processes the solute molecules to be transported are encapsulated in semipermeable, flexible membrane vesicles of micron size. We study the swelling of such fluctuating capsules, as the number of encapsulated particles is increased, or the concentration of the outer solution is decreased. The approach to the maximum volume-to-area ratio and the associated buildup of membrane tension involve a continuous phase transition and follow universal scaling laws. The criticality and its features are model-independent, arising solely from the interplay between volume and surface degrees of freedom.ootnotetextE. Haleva and H. Diamant, Phys. Rev. Lett. 101, 078104 (2008).

  9. Stretch-dependent changes in surface profiles of the human crystalline lens during accommodation: a finite element study.

    Science.gov (United States)

    Pour, Hooman Mohammad; Kanapathipillai, Sangarapillai; Zarrabi, Khosrow; Manns, Fabrice; Ho, Arthur

    2015-03-01

    A non-linear isotropic finite element (FE) model of a 29-year-old human crystalline lens was constructed to study the effects of various geometrical parameters on lens accommodation. The model simulates dis-accommodation by stretching of the lens and predicts the change in surface profiles of the lens capsule, cortex and nucleus at select states of stretching/accommodation. Multiple regression analysis (MRA) is used to develop a stretch-dependent mathematical model relating the lens sagittal height to the radial position of the lens surface as a function of dis-accommodative stretch. A load analysis is performed to compare the finite element results to empirical results from lens stretcher studies. Using the predicted geometrical changes, the optical response of the whole eye during accommodation was analysed by ray-tracing. Aspects of lens shape change relative to stretch were evaluated, including change in diameter, central thickness and accommodation. Maximum accommodation achieved was 10.29 D. From the multiple regression analysis, the stretch-dependent mathematical model of the lens shape related lens curvatures as a function of lens ciliary stretch well (maximum mean-square residual error 2.5 × 10(-3 ) μm, p < 0.001). The results are compared with those from in vitro studies. The finite element and ray-tracing predictions are consistent with Ex Vivo Accommodation Simulator (EVAS) studies in terms of load and power change versus change in thickness. The mathematical stretch-dependent model of accommodation presented may have utility in investigating lens behaviour at states other than the relaxed or fully accommodated states. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.

  10. A modified-simple technique of removing the lens cortex during cataract surgery

    Directory of Open Access Journals (Sweden)

    Kyung Eun Han

    2017-01-01

    Full Text Available We describe here a surgical technique of removing the remaining cortex after phacoemulsification without performing the conventional irrigation/aspiration (I/A procedure. In this technique, the remaining cortex attached to the posterior capsule was separated and dissected into several pieces by continuous irrigation with balanced salt solution, which was supplied through a syringe attached to a bent, blunt-tip needle. Approximately, 10 s of manual irrigation separated most of the remaining cortex from the posterior capsule. Then, the capsular bag was inflated with an ophthalmic viscoelastic device (OVD, and this pushed the separated cortex toward the capsular fornix mechanically. An intraocular lens was inserted into the capsular bag, following which the remaining cortex and OVD were removed concomitantly using an automated I/A handpiece. This technique is a simple and easy maneuver to remove the cortex from all areas, including the subincisional area, and reduce the possibility of a posterior capsule tear.

  11. [Corneal protection in contact lens users].

    Science.gov (United States)

    Egorova, G B; Mitichkina, T S; Shamsudinova, A R

    2014-01-01

    To evaluate the efficacy of corneoprotective agents (Corneregel and Solcoseryl) in contact lens users. A total of 66 long-term contact lens wearers with dry eye symptoms and varying degrees of corneal epitheliopathy were monitored. All patients used artificial tears, which, however, were not effective enough to suppress manifestations of corneal epitheliopathy and to release the associated discomfort. The therapy was supplemented with Corneregel. The following examination methods were applied: biomicroscopy with fluorescent staining, Norn test, Schirmer's test, advanced tearscopy with digital image analysis of the precorneal tear film lipid layer, corneal confocal microscopy. In all cases the assessment was performed prior to starting Corneregel and repeated in 7 days, 14 days and 1 month. Complete corneal re-epithelization and restoration of the most superficial layer of the epithelium were achieved within 7-14 days. In case of severe initial epitheliopathy the effect of Corneregel was not sufficient and epithelium defects remained. These patients additionally received Solcoseryl Eye Gel. After the treatment course the condition of corneal epithelium ameliorated and contact lens wearing comfort increased. A longer precorneal tear film break-up time indicated an increase of tear film stability. The total tear production did not change significantly. The moistening effect of Corneregel and low-viscosity artificial tears together with intensive regeneration of corneal epithelium enables structural recovery of the epithelial membrane and considerable improvement of the anterior corneal stroma. At the first stage of corneoprotective treatment it is appropriate to use preservative-free artificial tears of low and high viscosity. If the effect of tear substitutive therapy is unsatisfactory it is recommended to prescribe Corneregel and Solcoseryl. The regimen is to be adjusted individually.

  12. Indirect MR arthrographic findings of adhesive capsulitis.

    Science.gov (United States)

    Song, Kyoung Doo; Kwon, Jong Won; Yoon, Young Cheol; Choi, Sang-Hee

    2011-12-01

    The objective of our study was to compare the indirect MR arthrographic findings of patients with adhesive capsulitis and patients without adhesive capsulitis. Indirect MR arthrograms of 35 patients (21 women, 14 men; mean age, 50.1 years) diagnosed with adhesive capsulitis clinically were compared with indirect MR arthrograms of 45 patients (23 women, 22 men; mean age, 48.9 years) without adhesive capsulitis. Joint capsule thickness in the axillary recess and the thicknesses of the enhancing portion of the axillary recess and the rotator interval were, respectively, evaluated on coronal T2-weighted images and coronal and sagittal fat-suppressed enhanced T1-weighted images by two radiologists independently. Reliability was studied using the intraclass correlation coefficient (ICC). Receiver operating characteristic (ROC) curves were compared. Patients with adhesive capsulitis had significantly thickened joint capsules in the axillary recess and a thickened enhancing portion in the axillary recess and in the rotator interval. The difference in the thicknesses of the enhancing portion in the axillary recess and in the rotator interval were significantly greater than the difference in joint capsule thicknesses in the axillary recess between the adhesive capsulitis group and the control group (p capsule in the axillary recess and the thicknesses of the enhancing portion of the axillary recess and the rotator interval were 0.797, 0.861, and 0.847, respectively. An abundance of enhancing tissue in the rotator interval and thickening and enhancement of the axillary recess are signs suggestive of adhesive capsulitis on indirect MR arthrography.

  13. DIABETES AND SHOULDER ADHESIVE CAPSULITIS

    Directory of Open Access Journals (Sweden)

    J. Mohanakrishnan

    2016-08-01

    Full Text Available Background: Adhesive capsulitis (AC of shoulder is a common condition encountered by physical therapists in their routine outpatient care services; AC of shoulder is as by itself being a self limiting disorder lasts from months to years causing pain and discomfort to the patients. The condition is commonly associated with Diabetes mellitus or other co morbidities. The incidence of AC is high among diabetic individuals and it becomes mandatory on the part of physical therapists and other health professionals to approach this issue on a holistic manner. This paper deals with the importance of a physiotherapist role in prevention and dealing with the causative factors of AC and not merely its symptom. Methods: Extensive literature review was done from the electronic data bases, Systematic reviews and critical reviews from Pub med indexed journals and other peer reviewed publications across the globe. Results: It was not the type of diabetes but the duration of the disease and the glycemic index, marking the causative factor for adhesive capsulitis of shoulder. Conclusion: It may be concluded that physiotherapist play a vital role in identifying the pre-diabetic or a diabetic state of an individual reporting in a multi disciplinary set up with a AC of shoulder, and also has a role in the prevention of AC by helping the individual to maintain a good glycemic control with a holistic approach which includes aerobic exercises, General Flexibility exercises, Weight management and Yoga therapy.

  14. Application and experience of anterior vitrectomy in phacoemulsification

    Directory of Open Access Journals (Sweden)

    Xiao-Bo Zeng

    2016-02-01

    Full Text Available AIM: To observe and discuss the clinical application and effect of anterior vitrectomy in phacoemulsification for the treatment of vitreous prolapse caused by posterior capsular rupture or suspensory ligament transection.METHODS:Retrospective analysis of 28 cases(35 eyeswith cataract in whom vitreous prolapse caused by posterior capsular rupture or suspensory ligament transection occurred in phacoemulsification and intraocular lens implantation and anterior vitrectomy were performed was conducted. RESULTS:Anterior vitrectomy for timely and accurate treatment for vitreous prolapse caused by posterior capsular rupture or suspensory ligament transection occurred in phacoemulsification was satisfied. CONCLUSION: Anterior vitrectomy has good curative effect for vitreous prolapse caused by posterior capsular rupture or suspensory ligament transection occurred in phacoemulsification and is effective with less severe complications.

  15. Wireless capsule endoscopy of the small bowel: development, testing, and first human trials

    Science.gov (United States)

    Swain, Paul; Iddan, Gavriel J.; Meron, Gavriel; Glukhovsky, Arkady

    2001-01-01

    Small bowel endoscopy with existing endoscopes is limited by problems of discomfort and the technical difficulty of advancing far into the small-bowel. Our aim has been to develop and test wireless capsule endoscopy. Wireless endoscopes, in the form of capsules (11 x 33 mm), were constructed by Given Imaging. These were powered by silver oxide batteries and each contained a CMOS imaging chip and miniature processor, white light emitting diodes (LEDs), a short focal length lens, and a miniature transmitter and antenna. Two video frames per second were transmitted, using radio-frequency (approx. 410 MHz), to an array of aerials attached to the body. The array of aerials can also be used to calculate the position of the capsule in the body. The images were stored on a portable recorder carried on a belt and subsequently downloaded for analysis. The batteries allow more than 5 hours of recording, although the capsule generally passes through the whole small bowel in under two hours. Clear video images of the human bowel were recorded from the pylorus to the caecum. Wireless endoscopy, for the first time, allows painless optical imaging of the whole of the small bowel.

  16. A Class I UV-Blocking (senofilcon A) Soft Contact Lens Prevents UVA-induced Yellow Fluorescence and NADH loss in the Rabbit Lens Nucleus in vivo

    Science.gov (United States)

    Giblin, Frank J.; Lin, Li-Ren; Simpanya, Mukoma F.; Leverenz, Victor R.; Fick, Catherine E.

    2012-01-01

    It is known that fluorescence, much of it caused by UVA light excitation, increases in the aging human lens, resulting in loss of sharp vision. This study used an in vivo animal model to investigate UVA-excited fluorescence in the rabbit lens, which contains a high level of the UVA chromophore NADH, existing both free and bound to λ-crystallin. Also, the ability of a Class I (senofilcon A) soft contact lens to protect against UVA-induced effects on the rabbit lens was tested. Rabbit eyes were irradiated with UVA light in vivo (100 mW/cm2 on the cornea) for 1 hour using monochromatic 365 nm light. Irradiation was conducted in the presence of either a senofilcon A contact lens, a minimally UV-absorbing lotrafilcon A contact lens, or no contact lens at all. Eyes irradiated without a contact lens showed blue 365 nm-excited fluorescence initially, but this changed to intense yellow fluorescence after 1 hour. Isolated, previously irradiated lenses exhibited yellow fluorescence originating from the lens nucleus when viewed under 365 nm light, but showed normal blue fluorescence arising from the cortex. Previously irradiated lenses also exhibited a faint yellow color when observed under visible light. The senofilcon A contact lens protected completely against the UVA-induced effects on fluorescence and lens yellowing, whereas the lotrafilcon A lens showed no protection. The UVA-exposure also produced a 53% loss of total NADH (free plus bound) in the lens nucleus, with only a 13% drop in the anterior cortex. NADH loss in the nucleus was completely prevented with use of a senofilcon A contact lens, but no significant protection was observed with a lotrafilcon A lens. Overall, the senofilcon A lens provided an average of 67% protection against UVA-induced loss of four pyridine nucleotides in four different regions of the lens. HPLC analysis with fluorescence detection indicated a nearly six-fold increase in 365 nm-excited yellow fluorescence arising from lens nuclear

  17. The balanced two-string technique for sulcus intraocular lens implantation in the absence of capsular support.

    Science.gov (United States)

    Ibrahim, Hesham A; Sabry, Heba Nabil

    2015-01-01

    Purpose. To describe and explore an alternative approach for sulcus intraocular lens (IOL) implantation in the absence of capsular support. Methods. The commonly available one-piece poly(methyl methacrylate) (PMMA) lens is stabilized in the sulcus by two intraocular horizontal strings of 10/0 polypropylene suture passed through the lens dialing holes in opposite directions to achieve a mechanical balance. The horizontal strings of 10/0 polypropylene work as a rail track for the IOL optics, allowing some side to side lens adjustment even following wound closure. The stability of the IOL was tested in vitro. Six aphakic patients underwent in-sulcus IOL secondary implantation using the balanced two-string technique. Patients were followed up for a minimum of six months. Best spectacle corrected vision was assessed. Lens centration and lens tilt were measured by anterior segment optical coherence tomography (AS-OCT). Results. All patients had successful lens insertion. Best spectacle corrected visual acuity (BSCVA) improved in all patients. Lens decentration ranged between 0.21 mm and 0.9 mm (average 0.53 mm). Lens tilt ranged between 1.2° and 2.8° (average 2.17°). Conclusion. The mechanically balanced two-string technique is an alternative option for sulcus IOL implantation in absence of capsular support, allowing lens centration adjustment with no additional risks.

  18. The Balanced Two-String Technique for Sulcus Intraocular Lens Implantation in the Absence of Capsular Support

    Science.gov (United States)

    Ibrahim, Hesham A.; Sabry, Heba Nabil

    2015-01-01

    Purpose. To describe and explore an alternative approach for sulcus intraocular lens (IOL) implantation in the absence of capsular support. Methods. The commonly available one-piece poly(methyl methacrylate) (PMMA) lens is stabilized in the sulcus by two intraocular horizontal strings of 10/0 polypropylene suture passed through the lens dialing holes in opposite directions to achieve a mechanical balance. The horizontal strings of 10/0 polypropylene work as a rail track for the IOL optics, allowing some side to side lens adjustment even following wound closure. The stability of the IOL was tested in vitro. Six aphakic patients underwent in-sulcus IOL secondary implantation using the balanced two-string technique. Patients were followed up for a minimum of six months. Best spectacle corrected vision was assessed. Lens centration and lens tilt were measured by anterior segment optical coherence tomography (AS-OCT). Results. All patients had successful lens insertion. Best spectacle corrected visual acuity (BSCVA) improved in all patients. Lens decentration ranged between 0.21 mm and 0.9 mm (average 0.53 mm). Lens tilt ranged between 1.2° and 2.8° (average 2.17°). Conclusion. The mechanically balanced two-string technique is an alternative option for sulcus IOL implantation in absence of capsular support, allowing lens centration adjustment with no additional risks. PMID:25722884

  19. The Balanced Two-String Technique for Sulcus Intraocular Lens Implantation in the Absence of Capsular Support

    Directory of Open Access Journals (Sweden)

    Hesham A. Ibrahim

    2015-01-01

    Full Text Available Purpose. To describe and explore an alternative approach for sulcus intraocular lens (IOL implantation in the absence of capsular support. Methods. The commonly available one-piece poly(methyl methacrylate (PMMA lens is stabilized in the sulcus by two intraocular horizontal strings of 10/0 polypropylene suture passed through the lens dialing holes in opposite directions to achieve a mechanical balance. The horizontal strings of 10/0 polypropylene work as a rail track for the IOL optics, allowing some side to side lens adjustment even following wound closure. The stability of the IOL was tested in vitro. Six aphakic patients underwent in-sulcus IOL secondary implantation using the balanced two-string technique. Patients were followed up for a minimum of six months. Best spectacle corrected vision was assessed. Lens centration and lens tilt were measured by anterior segment optical coherence tomography (AS-OCT. Results. All patients had successful lens insertion. Best spectacle corrected visual acuity (BSCVA improved in all patients. Lens decentration ranged between 0.21 mm and 0.9 mm (average 0.53 mm. Lens tilt ranged between 1.2° and 2.8° (average 2.17°. Conclusion. The mechanically balanced two-string technique is an alternative option for sulcus IOL implantation in absence of capsular support, allowing lens centration adjustment with no additional risks.

  20. Compliance among soft contact lens wearers.

    OpenAIRE

    Kuzman, Tomislav; Barišić Kutija, Marija; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurišić, Darija; Škegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-01-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in ...

  1. Passive sorting of capsules by deformability

    Science.gov (United States)

    Haener, Edgar; Juel, Anne

    We study passive sorting according to deformability of liquid-filled ovalbumin-alginate capsules. We present results for two sorting geometries: a straight channel with a half-cylindrical obstruction and a pinched flow fractioning device (PFF) adapted for use with capsules. In the half-cylinder device, the capsules deform as they encounter the obstruction, and travel around the half-cylinder. The distance from the capsule's centre of mass to the surface of the half-cylinder depends on deformability, and separation between capsules of different deformability is amplified by diverging streamlines in the channel expansion downstream of the obstruction. We show experimentally that capsules can be sorted according to deformability with their downstream position depending on capillary number only, and we establish the sensitivity of the device to experimental variability. In the PFF device, particles are compressed against a wall using a strong pinching flow. We show that capsule deformation increases with the intensity of the pinching flow, but that the downstream capsule position is not set by deformation in the device. However, when using the PFF device like a T-Junction, we achieve improved sorting resolution compared to the half-cylinder device.

  2. The future of wireless capsule endoscopy.

    Science.gov (United States)

    Swain, Paul

    2008-07-14

    We outline probable and possible developments with wireless capsule endoscopy. It seems likely that capsule endoscopy will become increasingly effective in diagnostic gastrointestinal endoscopy. This will be attractive to patients especially for cancer or varices detection because capsule endoscopy is painless and is likely to have a higher take up rate compared to conventional colonoscopy and gastroscopy. Double imager capsules with increased frame rates have been used to image the esophagus for Barrett's and esophageal varices. The image quality is not bad but needs to be improved if it is to become a realistic substitute for flexible upper and lower gastrointestinal endoscopy. An increase in the frame rate, angle of view, depth of field, image numbers, duration of the procedure and improvements in illumination seem likely. Colonic, esophageal and gastric capsules will improve in quality, eroding the supremacy of flexible endoscopy, and become embedded into screening programs. Therapeutic capsules will emerge with brushing, cytology, fluid aspiration, biopsy and drug delivery capabilities. Electrocautery may also become possible. Diagnostic capsules will integrate physiological measurements with imaging and optical biopsy, and immunologic cancer recognition. Remote control movement will improve with the use of magnets and/or electrostimulation and perhaps electromechanical methods. External wireless commands will influence capsule diagnosis and therapy and will increasingly entail the use of real-time imaging. However, it should be noted that speculations about the future of technology in any detail are almost always wrong.

  3. Panoramic lens applications revisited

    Science.gov (United States)

    Thibault, Simon

    2008-04-01

    During the last few years, innovative optical design strategies to generate and control image mapping have been successful in producing high-resolution digital imagers and projectors. This new generation of panoramic lenses includes catadioptric panoramic lenses, panoramic annular lenses, visible/IR fisheye lenses, anamorphic wide-angle attachments, and visible/IR panomorph lenses. Given that a wide-angle lens images a large field of view on a limited number of pixels, a systematic pixel-to-angle mapping will help the efficient use of each pixel in the field of view. In this paper, we present several modern applications of these modern types of hemispheric lenses. Recently, surveillance and security applications have been proposed and published in Security and Defence symposium. However, modern hemispheric lens can be used in many other fields. A panoramic imaging sensor contributes most to the perception of the world. Panoramic lenses are now ready to be deployed in many optical solutions. Covered applications include, but are not limited to medical imaging (endoscope, rigiscope, fiberscope...), remote sensing (pipe inspection, crime scene investigation, archeology...), multimedia (hemispheric projector, panoramic image...). Modern panoramic technologies allow simple and efficient digital image processing and the use of standard image analysis features (motion estimation, segmentation, object tracking, pattern recognition) in the complete 360° hemispheric area.

  4. CONGENITAL ANTERIOR TIBIOFEMURAL SUBLUXATION

    Directory of Open Access Journals (Sweden)

    A. Shahla

    2008-06-01

    Full Text Available Congenital anterior tibiofemoral subluxation is an extremely rare disorder. All reported cases accompanied by other abnormalities and syndromes. A 16-year-old high school girl referred to us with bilateral anterior tibiofemoral subluxation as the knees were extended and reduced at more than 30 degrees flexion. Deformities were due to tightness of the iliotibial band and biceps femuris muscles and corrected by surgical release. Associated disorders included bilateral anterior shoulders dislocation, short metacarpals and metatarsals, and right calcaneuvalgus deformity.

  5. Growth of the human lens in the Indian adult population: Preliminary observations

    Directory of Open Access Journals (Sweden)

    Ashik Mohamed

    2012-01-01

    Full Text Available Context: The eye lens grows throughout life by the addition of new cells inside the surrounding capsule. How this growth affects the properties of the lens is essential for understanding disorders such as cataract and presbyopia. Aims: To examine growth of the human lens in the Indian population and compare this with the growth in Western populations by measuring in vitro dimensions together with wet and dry weights. Settings and Design: The study was conducted at the research wing of a tertiary eye care center in South India and the study design was prospective. Materials and Methods: Lenses were removed from eye bank eyes and their dimensions measured with a digital caliper. They were then carefully blotted dry and weighed before being placed in 5% buffered formalin. After 1 week fixation, the lenses were dried at 80 °C until constant weight was achieved. The constant weight was noted as the dry weight of the lens. Statistical Analysis Used: Lens parameters were analyzed as a function of age using linear and logarithmic regression methods. Results: Data were obtained for 251 lenses, aged 16-93 years, within a median postmortem time of 22 h. Both wet and dry weights increased linearly at 1.24 and 0.44 mg/year, respectively, throughout adult life. The dimensions also increased continuously throughout this time. Conclusions: Over the age range examined, lens growth in the Indian population is very similar to that in Western populations.

  6. Growth of the human lens in the Indian adult population: preliminary observations.

    Science.gov (United States)

    Mohamed, Ashik; Sangwan, Virender S; Augusteyn, Robert C

    2012-01-01

    The eye lens grows throughout life by the addition of new cells inside the surrounding capsule. How this growth affects the properties of the lens is essential for understanding disorders such as cataract and presbyopia. To examine growth of the human lens in the Indian population and compare this with the growth in Western populations by measuring in vitro dimensions together with wet and dry weights. The study was conducted at the research wing of a tertiary eye care center in South India and the study design was prospective. Lenses were removed from eye bank eyes and their dimensions measured with a digital caliper. They were then carefully blotted dry and weighed before being placed in 5% buffered formalin. After 1 week fixation, the lenses were dried at 80 °C until constant weight was achieved. The constant weight was noted as the dry weight of the lens. Lens parameters were analyzed as a function of age using linear and logarithmic regression methods. Data were obtained for 251 lenses, aged 16-93 years, within a median postmortem time of 22 h. Both wet and dry weights increased linearly at 1.24 and 0.44 mg/year, respectively, throughout adult life. The dimensions also increased continuously throughout this time. Over the age range examined, lens growth in the Indian population is very similar to that in Western populations.

  7. Scleral Fixation of a One-Piece Toric Intraocular lens

    Science.gov (United States)

    Emanuel, Matthew E.; Randleman, J. Bradley; Masket, Samuel

    2013-01-01

    Purpose To describe a novel technique for toric intraocular lens (IOL) repositioning and fixation in the absence of adequate capsular support Methods Case report and literature review Results Two cases are presented with scleral fixation of a one-piece toric IOL (SN6AT series, Alcon Inc.) In both cases, toric IOLs initially placed within the capsular bag became decentered due to poor capsular support and/or posterior capsule rupture. To avoid the potential complications of lens explantation and maintain the astigmatic benefits of the toric IOL, scleral fixation of the lenses was performed. The Hoffman technique was used to create reverse scleral pockets without conjunctival dissection. A 10-0 suture was used to capture and then secure the lens haptics in a lasso-type fashion. Sutures were then buried within the previously created scleral pockets. Both patients had well centered lenses postoperatively and have remained stable at last follow-up, up to thirty months postoperatively. Conclusion In the absence of adequate capsular support, scleral fixation is a viable option for one-piece toric IOL fixation to avoid IOL explanation PMID:23380416

  8. Clinical observation of Artisan iris-clip intraocular lens implantation at stage Ⅰ

    Directory of Open Access Journals (Sweden)

    Qing Zhou

    2014-09-01

    Full Text Available AIM: To observe the clinical efficacy of Artisan iris-clip intraocular lens(IOLimplantation on cataract with a wide range of lens dislocation.METHODS: Twenty-four hospital patients(28 eyesof cataract with lens subluxation by trauma(20 patients, 20 eyesand Marfan's syndrome(4 patients, 8 eyesduring May 2007 to December 2011 were selected. All of them underwent phacoemulsification or an anterior vitrectomy and Artisan iris-clip IOL implantation at stage Ⅰ. Postoperative visual acuity, corneal endothelial cell count, intraocular lens position and postoperative complications were observed. Follow-up time was 6mo.RESULTS:Compared with the preoperative, postoperative best corrected visual acuity improved to varying degrees, visual acuity of 0.1-0.5 was in 20 eyes, 0.5-1.0 in 8 eyes. After followed up 1-6mo, no artificial lens shift, iris inflammation, iris atrophy and corneal decompensation and other complications were observed.CONCLUSION: Cataract surgery with a wide range of lens dislocation is difficult, but as long as surgeons who have a wealth of clinical experience and superb skills, still can carry out phacoemulsification surgery or anterior vitrectomy and Artisan iris-clip IOL implantation and obtain a better outcome.

  9. Posterior capsule opacification and neovascularization treated with intravitreal bevacizumab and Nd:YAG capsulotomy

    Science.gov (United States)

    Sánchez-Castro, Grimelda Yuriana; Hitos-Fájer, Alejandra; Mendoza-Schuster, Erick; Velez-Montoya, Raul; Velasco-Barona, Cecilio Francisco

    2008-01-01

    We reported a 75-year-old diabetic man, who developed opacification and neovascularization of the posterior capsule after extracapsular cataract extraction and posterior chamber intraocular lens implantation. The patient was treated with two injections of 2.5 mg of intravitreal bevacizumab. The treatment produced an important regression of the posterior capsular new vessels, allowing us to perform a successful Nd:YAG capsulotomy, clearing the visual axis and improving the visualization of the posterior pole. Even though, best corrected visual acuity was 20/200 due to diabetic macular edema. PMID:19668770

  10. Adhesive capsulitis of the shoulder: MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jeong; Han, Tae Il; Lee, Kwang Won; Choi, Youn Seon; Kim, Dae Hong; Han, Hyun Young; Song, Mun Kab [Eulji Univ. School of Medicine, Taejon (Korea, Republic of); Kwon, Soon Tae [Chungnam National Univ. College of Medicine, Taejon (Korea, Republic of)

    2001-07-01

    Adhesive capsulitis is a clinical syndrome involving pain and decreased joint motion caused by thickening and contraction of the joint capsule. The purpose of this study is to describe the MR arthrographic findings of this syndrome. Twenty-nine sets of MR arthrographic images were included in the study. Fourteen patients had adhesive capsulitis diagnosed by physical examination and arthrography, and their MR arthrographic findings were compared with those of 15 subjects in the control group. The images were retrospectively reviewed with specific attention to the thickness of the joint capsule, volume of the axillary pouch (length, width, height(depth)), thinkness of the coracohumeral ligament, presence of extra-articular contrast extravasation, and contrst filling of the subcoracoid bursa. Mean capsular thickness measured at the inferior portion of the axillary pouch was 4.1 mm in patients with adhesive capsulitis and 1.5 mm in the control group. The mean width of the axillary pouch was 2.5 mm in patients and 9.5 mm in controls. In patients, the capsule was significantly thicker and the axillary pouch significantly narrower than in controls (p<0.05). Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch (sensitivity 93%, specificity 80%) and a pouch narrower than 3.5 mm (sensitivity 93%, specificity 100%) were useful criteria for the diagnosis of adhesive capsulitis. In patients with this condition, extra-articular contrast extravasation was noted in six patients (43%) and contrast filling of the subcoracoid bursa in three (21%). The MR arthrographic findings of adhesive capsulitis are capsular thickening, a low-volume axillary pouch, extra-articular contrast extravasation, and contrast filling of the subcoracoid bursa. Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch and a pouch width of less than 3.5 mm are useful diagnostic imaging characteristics.

  11. Thermoregulation of Capsule Production by Streptococcus pyogenes

    Science.gov (United States)

    Kang, Song Ok; Wright, Jordan O.; Tesorero, Rafael A.; Lee, Hyunwoo; Beall, Bernard; Cho, Kyu Hong

    2012-01-01

    The capsule of Streptococcus pyogenes serves as an adhesin as well as an anti-phagocytic factor by binding to CD44 on keratinocytes of the pharyngeal mucosa and the skin, the main entry sites of the pathogen. We discovered that S. pyogenes HSC5 and MGAS315 strains are further thermoregulated for capsule production at a post-transcriptional level in addition to the transcriptional regulation by the CovRS two-component regulatory system. When the transcription of the hasABC capsular biosynthetic locus was de-repressed through mutation of the covRS system, the two strains, which have been used for pathogenesis studies in the laboratory, exhibited markedly increased capsule production at sub-body temperature. Employing transposon mutagenesis, we found that CvfA, a previously identified membrane-associated endoribonuclease, is required for the thermoregulation of capsule synthesis. The mutation of the cvfA gene conferred increased capsule production regardless of temperature. However, the amount of the capsule transcript was not changed by the mutation, indicating that a post-transcriptional regulator mediates between CvfA and thermoregulated capsule production. When we tested naturally occurring invasive mucoid strains, a high percentage (11/53, 21%) of the strains exhibited thermoregulated capsule production. As expected, the mucoid phenotype of these strains at sub-body temperature was due to mutations within the chromosomal covRS genes. Capsule thermoregulation that exhibits high capsule production at lower temperatures that occur on the skin or mucosal surface potentially confers better capability of adhesion and invasion when S. pyogenes penetrates the epithelial surface. PMID:22615992

  12. Efficacy on chopping with lens loop-pad in the small incision extracapsular cataract surgery with intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Xiao-Ning Peng

    2014-04-01

    Full Text Available AIM: To study the clinical effects of chopping with lens loop-pad in the small incision extracapsular cataract surgery with intraocular lens implantation.METHODS:A total of 75 cases(80 eyes, in which loop-pad and chop knife were performed to chop nucleus before implanting intraocular lens. Visual acuity, postoperative astigmatism degree, intraoperative and postoperative complications were observed. The post-operative follow-up periods ranged from 3 to 12mo.RESULTS: The visual acuity was 0.3-0.5 in 37 eyes and 0.6 or better in 21 eyes at 1d, while was respectively in 43 eyes and in 26 eyes at 1mo. Compared with preoperative astigmatism(0.85±0.29D, there were significant difference at postoperative 1wk(1.75±0.55D(PP>0.05. Intraoperative posterior capsule rupture occurred in 4 eyes, which implantation was successful in 1 eye and 3 eyes was managed viaciliary sulcus. Two eyes had dermatoglyphic pattern edema in corneal endothelium which recovered after about 3d. Two eyes had local patchy opacities which recovered in 2wk. Two eyes had transient high intraocular pressure.CONCLUSION: The surgery is efficient, low cost, easy process and less complications, it is worth to be popularized.

  13. Crystalline lens radioprotectors

    International Nuclear Information System (INIS)

    Belkacemi, Y.; Pasquier, D.; Castelain, B.; Lartigau, E.; Warnet, J.M.

    2003-01-01

    During more than a half of century, numerous compounds have been tested in different models against radiation-induced cataract. In this report, we will review the radioprotectors that have been already tested for non-human crystalline lens protection. We will focus on the most important published studies in this topic and the mechanisms of cyto-protection reported in. vitro and in. vivo from animals. The most frequent mechanisms incriminated in the cyto-protective effect are: free radical scavenging, limitation of lipid peroxidation, modulation of cycle progression increase of intracellular reduced glutathione pool, reduction of DNA strand breaks and limitation of apoptotic cell death. Arnifostine (or Ethyol) and anethole dithiolethione (or Sulfarlem), already used clinically as chemo- and radio-protectants, could be further test?r for ocular radioprotection particularly for radiation-induced cataract. (author)

  14. Anterior ankle impingement

    NARCIS (Netherlands)

    Tol, Johannes L.; van Dijk, C. Niek

    2006-01-01

    The anterior ankle impingement syndrome is a clinical pain syndrome that is characterized by anterior ankle pain on (hyper) dorsiflexion. The plain radiographs often are negative in patients who have anteromedial impingement. An oblique view is recommended in these patients. Arthroscopic excision of

  15. [Evaluation of nopal capsules in diabetes mellitus].

    Science.gov (United States)

    Frati Munari, A C; Vera Lastra, O; Ariza Andraca, C R

    1992-01-01

    To find out if commercial capsules with dried nopal (prickle-pear cactus, Opuntia ficus indica may have a role in the management of diabetes mellitus, three experiments were performed: 30 capsules where given in fasting condition to 10 diabetic subjects and serum glucose was measured through out 3 hours; a control test was performed with 30 placebo capsules. OGTT with previous intake of 30 nopal or placebo capsules was performed in ten healthy individuals. In a crossover and single blinded study 14 diabetic patients withdrew the oral hypoglycemic treatment and received 10 nopal or placebo capsules t.i.d. during one week; serum glucose, cholesterol and tryglycerides levels were measured before and after each one-week period. Five healthy subjects were also studied in the same fashion. Opuntia capsules did not show acute hypoglycemic effect and did not influence OGTT. In diabetic patients serum glucose, cholesterol and tryglycerides levels did not change with Opuntia, but they increased with placebo (P nopal, while cholesterol and triglycerides decreased (P < 0.01 vs. placebo). The intake of 30 Opuntia capsules daily in patients with diabetes mellitus had a discrete beneficial effect on glucose and cholesterol. However this dose is unpractical and at present it is not recommended in the management of diabetes mellitus.

  16. Ectopic intraocular lens: An unusual complication of cataract surgery

    Directory of Open Access Journals (Sweden)

    Mehul A Shah

    2014-01-01

    Full Text Available We wish to report an unusual complication of intraocular lens (IOL insertion following uneventful phacoemulsification. After successful phacoemulsification surgery, a hydrophobic acrylic IOL was loaded in the injector for insertion into the capsular bag. During insertion, the IOL inadvertently extended into the corneal stromal lamella. The complication was recognized at a late stage, and the foldable acrylic lens was retrieved and reinserted correctly in the bag. The anterior chamber was made viscoelastically taut and was maintained in this state for 10 min, followed by a routine viscoelastic wash and air bubble injection. Cornea was slightly edematous with stromal haze, and the corneal thickness was 908 μm. At the 1-month follow-up visit, the patient′s vision was 20/40, the stromal haze had subsided, the corneal thickness was 572 μm, and the patient was comfortable. Though it was unknown complication, following proper management patient recovered satisfactorily.

  17. Intrauterine fertilization capsules--a clinical trial

    DEFF Research Database (Denmark)

    Lenz, S; Lindenberg, S; Sundberg, K

    1991-01-01

    Treatment of 26 women with tubal infertility was attempted using intrauterine capsules loaded with oocytes and spermatozoa. The stimulation protocol was as used for in vitro fertilization and embryo transfer and consisted of short-term use of Buserelin, human menopausal gonadotropin, and human...... and piston from an intrauterine device. Six complete capsules and parts of two other capsules were expelled. None of the women became pregnant, compared with a pregnancy rate of 21% per aspiration following in vitro fertilization and embryo transfer during the same period....

  18. Colon capsule endoscopy: toward the future.

    Science.gov (United States)

    Muguruma, Naoki; Tanaka, Kumiko; Teramae, Satoshi; Takayama, Tetsuji

    2017-02-01

    Colon capsule endoscopy is a wireless and minimally invasive technique for visualization of the whole colon. With recent improvements of technical features in second-generation systems, a more important role for colon capsule endoscopy is rapidly emerging. Although several limitations and drawbacks are yet to be resolved, its usefulness as a tool for colorectal cancer screening and monitoring disease activity in inflammatory bowel diseases has become more apparent with increased use. Further investigations, including multicenter trials, are required to evaluate the substantial role of the colon capsule in managing colorectal diseases.

  19. The environmental psychology of capsule habitats.

    Science.gov (United States)

    Suedfeld, P; Steel, G D

    2000-01-01

    Capsule habitats make it possible for human beings to survive and function in environments that would otherwise be lethal, such as space, the ocean depths, and the polar regions. The number of people entering capsules in the course of their work or for purposes of recreation is constantly increasing. However, long-term living in such habitats imposes physical and psychological risks as well as offering opportunities and benefits. This paper reviews what is known about the environmental, social, and personality aspects of adaptation to capsules, including sources of stress, selection criteria, obstacles to and facilitators of adequate coping, changes in group interaction, the role of temporal factors, and post-mission consequences.

  20. Comparison of Two Intraocular Lens Implantation Techniques in Pediatric Cataract Surgery in Terms of Postoperative Complications

    Directory of Open Access Journals (Sweden)

    Mustafa Erdoğan Cicik

    2018-03-01

    Full Text Available Background: Pediatric cataract surgery differs substantially from adult cataract surgery. Numerous studies have focused on reducing the development of postoperative complications. Aims: To compare two intraocular lens implantation techniques used in pediatric cataract surgery in terms of postoperative complications. Study Design: Case-control study. Methods: Patients who underwent pediatric cataract surgery and intraocular lens implantation between 2008 and 2016 were evaluated in this retrospective study. Patients aged 3-15 years with unilateral or bilateral cataract and without corneal pathology were included in the study. The patients were categorized into the following two groups: those who underwent posterior capsulorhexis and anterior vitrectomy using in-the-bag intraocular lens implantation (group 1 and those who underwent posterior capsulorhexis and intraocular lens implantation with the optic fixed behind the posterior capsulorhexis (group 2. Rates of postoperative visual axis opacification and complications (glaucoma, posterior synechiae, uveitic reaction, and intraocular lens decentration were evaluated in these groups. The implanted intraocular lenses were either monoblock (AcrySof SN60AT intraocular lens, triple-piece (AcrySof MA60BM intraocular lens foldable hydrophobic acrylic lenses, or multifocal lenses (AcrySof IQ ReSTOR. Results: This retrospective study included 52 eyes of 37 patients. Group 1 comprised 26 eyes of 20 patients and group 2 comprised 26 eyes of 17 patients. During the follow-up, visual axis opacification was observed in two patients in group 1 but no patients in group 2. Regarding postoperative complications, there was no uveitic reaction, posterior synechiae, or intraocular lens decentration in either group. There was no significant difference between the groups in terms of the postoperative complications (p>0.05. Conclusion: There was no significant difference between in-the-bag intraocular lens implantation

  1. Analysis of causes of intraocular lens explantations in the material of Department of Ophthalmology, Medical University of Lodz.

    Science.gov (United States)

    Wilczyński, Michał; Wilczyńska, Olena; Omulecki, Wojciech

    2009-01-01

    Implantation of intraocular lenses (IOLS) has become a standard practice in cataract surgery, however, similar to any other type of surgery, using IOLs is not complication-free and sometimes explantation of intraocular lenses may be necessary. This study was to gather data and analyze causes of intraocular lens explantations, performed in the Department of Ophthalmology, Medical University of Łódź. The data were gathered from medical documentation of all patients who underwent intraocular lens removal from January 2003 to July 2006. The examined group consisted of 16 patients (16 eyes): 9 women (fraction 0.56), and 7 men (fraction 0.44), at the age from 21 to 82 years (mean age 62.4 years, SD +/- 15.5). In all patients IOL explantation was performed under local, peribulbar anaesthesia. Two groups of patients were distinguished: patients who had an anterior chamber lens explanted (3 patients, fraction 0.19) and patients who underwent posterior chamber lens explantation (13 patients, fraction 0.81). Causes of AC IOL explantations were: vaulting of the IOL (1 eye, fraction 0.06), luxation of the IOL to the vitreous cavity (1 eye, fraction 0.06), and painful eyeball after anterior chamber lens implantation (1 eye, fraction 0.06). Causes of PC IOL explantations were: subluxation of the IOL (6 eyes, fraction 0.38), luxation of the lens to the vitreous cavity (3 eyes, fraction 0.19), luxation of the lens to the anterior chamber (1 eye, fraction 0.06), endophthalmitis (2 eyes, fraction 0.13) and incorrect lens power (1 eye, fraction 0.06). In the majority of eyes (n = 13, fraction 0.81) the removed implant was replaced by another intraocular lens, but 3 eyes (fraction 0.19) were left aphakic. We did not observe serious intra- or early postoperative complications which might influence the final result of the operation.

  2. Comparison of lens oxidative damage induced by vitrectomy and/or hyperoxia in rabbits

    Directory of Open Access Journals (Sweden)

    Hong Yan

    2017-02-01

    Full Text Available AIM: To compare of lens oxidative damage induced by vitrectomy and/or hyperoxia in rabbit. METHODS: Sixteen New Zealand rabbits (2.4-2.5 kg were randomly divided into two groups (Group A, n=12; Group B, n=4. In Group A, the right eyes were treated with vitrectomy and systemic hyperoxia (oxygen concentration: 80%-85%, 1 ATA, 4h/d (Group A-right, and the left eyes were treated with hyperoxia without vitrectomy surgery (Group A-left. Four rabbits in group B (eight eyes were untreated as the controls. Lens transparency was monitored with a slit lamp and recorded before and after vitrectomy. After hyperoxic treatment for 6mo, the eyeballs were removed and the lens cortices (containing the capsules and nuclei were separated for further morphological and biochemical evaluation. RESULTS: Six months after treatments, there were no significant morphological changes in the lenses in any experimental group when observed with a slit lamp. However, the levels of water-soluble proteins and ascorbate, and the activities of catalase and Na+-K+-ATPase were significantly reduced, whereas the levels of malondialdehyde and transforming growth factor β2 (TGF-β2 were significantly elevated, in both the cortices and nuclei of eyes treated with vitrectomy and hyperoxia. The increase in protein-glutathione mixed disulfides and the reduction in water-soluble proteins were more obvious in the lens nuclei. The levels of ascorbate in the vitreous fluid were also reduced after vitrectomy, whereas TGF-β2 increased after vitrectomy and hyperoxia. Systemic hyperoxia exposure increased these effects. CONCLUSION: Removal of the intact vitreous gel with vitrectomy and exposing the lens to increased oxygen from the retina induce lens oxidation and aggregation. Thus, an intact vitreous gel structure may protect the lens from oxidative insult and maintain lens transparency.

  3. Contact Lens Wear at Altitude: Subcontact Lens Bubble Formation

    Science.gov (United States)

    1987-11-01

    incidence of (PMMA) lenses . Reported here are the results of contact lens subcontact lens bubble formation under scleral lenses at bubble studies with soft...vision from formation of large bubbles greater than 6,096 m (20,000 It). With soft contact lenses , bubble under their contact lenses . They also found...always located at the limbus and were without sequela to vision or corneal epithelial integrity. scleral lenses used by Jaeckle were permeable to gases

  4. Straylight Measurements in Contact Lens Wear

    NARCIS (Netherlands)

    van der Meulen, Ivanka J. E.; Engelbrecht, Leonore A.; van Vliet, Johannes M. J.; Lapid-Gortzak, Ruth; Nieuwendaal, Carla P.; Mourits, Maarten P.; Schlingemann, Reinier O.; van den Berg, Thomas J. T. P.

    2010-01-01

    Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens

  5. Polyamide capsules via soft templating with oil drops-1. Morphological studies of the capsule wall.

    Science.gov (United States)

    Essawy, Hisham; Tauer, Klaus

    2010-02-01

    Poly(terephthalamide) microcapsules can be reproducibly and easily prepared by interfacial polycondensation around emulsion droplets in water. Oil drops of cyclohexane/chloroform mixture stabilized with poly(vinyl alcohol) containing terephthaloylchloride serve as soft template. The interfacial polycondensation starts immediately after addition of an amine mixture (hexamethylenediamine/diethylenetriamine). Light and scanning electron microscopy prove the formation of capsules with size distribution in the range from a few up to 100 microm depending on particular composition of the reaction mixture. The morphology of the capsule wall is characterized by precipitated particles. If instead of pure organic solvents a reactive oil phase is used as template, the capsules can serve in subsequent reactions as templates for the synthesis of composite particles. In this way, styrene can be radically polymerized inside the capsule leading to composite capsules. The capsule morphology is determined by the partition of all components between all phases.

  6. Radiocarbon dating of the human eye lens crystallines reveal proteins without carbon turnover throughout life.

    Directory of Open Access Journals (Sweden)

    Niels Lynnerup

    Full Text Available BACKGROUND: Lens crystallines are special proteins in the eye lens. Because the epithelial basement membrane (lens capsule completely encloses the lens, desquamation of aging cells is impossible, and due to the complete absence of blood vessels or transport of metabolites in this area, there is no subsequent remodelling of these fibers, nor removal of degraded lens fibers. Human tissue ultimately derives its (14C content from the atmospheric carbon dioxide. The (14C content of the lens proteins thus reflects the atmospheric content of (14C when the lens crystallines were formed. Precise radiocarbon dating is made possible by comparing the (14C content of the lens crystallines to the so-called bomb pulse, i.e. a plot of the atmospheric (14C content since the Second World War, when there was a significant increase due to nuclear-bomb testing. Since the change in concentration is significant even on a yearly basis this allows very accurate dating. METHODOLOGY/PRINCIPAL FINDINGS: Our results allow us to conclude that the crystalline formation in the lens nucleus almost entirely takes place around the time of birth, with a very small, and decreasing, continuous formation throughout life. The close relationship may be further expressed as a mathematical model, which takes into account the timing of the crystalline formation. CONCLUSIONS/SIGNIFICANCE: Such a life-long permanence of human tissue has hitherto only been described for dental enamel. In confront to dental enamel it must be held in mind that the eye lens is a soft structure, subjected to almost continuous deformation, due to lens accommodation, yet its most important constituent, the lens crystalline, is never subject to turnover or remodelling once formed. The determination of the (14C content of various tissues may be used to assess turnover rates and degree of substitution (for example for brain cell DNA. Potential targets may be nervous tissues in terms of senile or pre

  7. Arterial blood supply to midbrain, thalamus and internal capsule on CT, 3

    International Nuclear Information System (INIS)

    Takeshita, Gen; Ottomo, Michinori; Sasaki, Taisuke; Fukuda, Eiko.

    1984-01-01

    The selective injection of dye into the anterior choroidal artery (blue), the medial posterior choroidal artery (green), and the lateral posterior choroidal artery (red), using seven post-mortem brains, was performed. After fixation, sections parallel with the orbito-meatal line were obtained. The distribution of the anterior choroidal artery was visualized in the uncal region of the temporal lobe and the cerebral peduncle below the slice of the third ventricle. On the slice of the third ventricle, the lateral part of the geniculate region, the globus pallidus, and the posterior limb of the internal capsule were supplied by the anterior choroidal artery. The blood supply of the posterior limb of the internal capsule was also demonstrated on the slice of the anterior horn and on the body of the lateral ventricle. The distribution of the medial posterior choroidal artery was visualized in the tegmentum of the midbrain below the slice of the third ventricle, and on the slice of the anterior horn, the pineal body and the posterior part of the thalamus were also supplied. The distribution of the lateral posterior choroidal artery was visualized in the lateral part of the midbrain, around the red nucleus, below the slice of the third ventricle, and on the slice of the third ventricle, the upper part of the cerebral peduncle, the posterior part of the hypothalamus, and the medial part of the geniculate region were also supplied. Also, distribution to the medial and posterior parts of the thalamus was noted on the slice of the anterior horn. It was quite useful to identify the distribution of each choroidal artery on CT sections for the CT diagnosis of cerebrovascular disorders. (author)

  8. Adhesive capsulitis of the shoulder: pain intensity and distribution.

    Science.gov (United States)

    Candela, V; Giannicola, G; Passaretti, D; Venditto, T; Gumina, S

    2017-12-01

    Papers regarding adhesive capsulitis (AC) of the shoulder focused on etiology, epidemiology, diagnosis, and treatment; until now, information on shoulder pain characteristics is still scarce. Our aim was to analyze pain intensity and distribution in patients with AC. The study group was composed of 278 (133M-145F) consecutive patients with AC. After diagnosis, shoulder pain distribution was assessed through an upper limb pain map and pain intensity through a visual analog scale. Patients were distinguished on the basis of gender, age, time elapsed from onset of symptoms, and severity of functional limitation. Data were submitted to statistical analysis. Intensity of shoulder pain caused by AC was higher in females (p pain arose from more than 3 months suffered a lower intensity of shoulder pain. Furthermore, pain intensity was higher in the most severe form of AC (active forward flexion Pain was localized predominantly on the anterior aspect of the shoulder (dermatomes C5-C6) and rarely extended beyond the distal third of the arm. No differences were found in pain distribution between male and female, between patients with pain from less or more than 3 months and between different levels of AC severity (p > 0.05). Shoulder pain due to AC may be influenced by gender and severity of functional limitation. AC pain distribution principally involves anterior aspect of the shoulder with downward extension of the arm until its distal third. Level IV.

  9. Therapeutic Capsule Endoscopy: Opportunities and Challenges

    Directory of Open Access Journals (Sweden)

    Mahdi Rasouli

    2011-01-01

    Full Text Available The increasing demand for non-invasive (or less-invasive monitoring and treatment of medical conditions has attracted both physicians and engineers to work together and investigate new methodologies. Wireless capsule endoscopy is a successful example of such techniques which has become an accepted routine for diagnostic inspection of the gastrointestinal tract. This method offers a non-invasive alternative to traditional endoscopy and provides the opportunity for exploring distal areas of the small intestine which are otherwise not accessible. Despite these advantages, wireless capsule endoscopy is still limited in functionality compared to traditional endoscopy. Wireless capsule endoscopes with advanced functionalities, such as biopsy or drug delivery, are highly desirable. In this article, the current status of wireless capsule endoscopy is reviewed together with some of its possible therapeutic applications as well as the existing challenges.

  10. Contact Lens Related Corneal Ulcer

    OpenAIRE

    Loh, KY; Agarwal, P

    2010-01-01

    A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...

  11. CAPSULE REPORT: HARD CHROME FUME ...

    Science.gov (United States)

    All existing information which includes the information extrapolated from the Hard Chrome Pollution Prevention Demonstration Project(s) and other sources derived from plating facilities and industry contacts, will be condensed and featured in this document. At least five chromium emission prevention/control devices have been tested covering a wide spectrum of techniques currently in use at small and large-sized chrome metal plating shops. The goal for limiting chromium emissions to levels specified in the MACT Standards are: (1) 0.030 milligrams per dry standard cubic meter of air (mg/dscm) for small facilities with existing tanks, (2) 0.015 mg/dscm for small facilities with new tanks or large facilities with existing or new tanks. It should be emphasized that chemical mist suppressants still have quality issues and work practices that need to be addressed when they are used. Some of the mist suppressants currently in use are: one-, two-, and three-stage mesh pad mist eliminators; composite mesh pad mist eliminators; packed-bed scrubbers and polyballs. This capsule report should, redominantly, emphasize pollution prevention techniques and include, but not be restricted to, the afore-mentioned devices. Information

  12. Capsule production by Pseudomonas aeruginosa

    Energy Technology Data Exchange (ETDEWEB)

    Lynn, A.R.

    1984-01-01

    Mucoid strains of Pseudomonas aeruginosa, associated almost exclusively with chronic respiratory infections in patients with cystic fibrosis, possess a capsule composed of alginic acid similar to one produced by Azotobacter vinelandii. Recent reports have provided evidence that the biosynthetic pathway for alginate in P. aeruginosa may differ from the pathway proposed for A. vinelandii in that synthesis in P. aeruginosa may occur by way of the Entner-Doudoroff pathway. Incorporation of isotope from (6-/sup 14/C)glucose into alginate by both P. aueroginosa and A. vinelandii was 10-fold greater than that from either (1-/sup 14/C)/sup -/ or (2-/sup 14/C)glucose, indicating preferential utilization of the bottom half of the glucose molecule for alginate biosynthesis. These data strongly suggest that the Entner-Doudoroff pathway plays a major role in alginate synthesis in both P. aeruginosa and A. vinelandii. The enzymes of carbohydrate metabolism in mucoid strains of P. aeruginosa appear to be unchanged whether alignate is actively produced or not and activities do not differ significantly from nonmucoid strain PAO.

  13. The history of time for capsule endoscopy.

    Science.gov (United States)

    Adler, Samuel N

    2017-05-01

    Capsule endoscopy was conceived by inventive minds of good people. In the beginning there was a will to do something for medicine. The idea fomented after a discourse between the talented engineer with his physician friend. It took years to develop the concept. Then excellent engineers created de novo the necessary components to turn the capsule into a viable reality. The story is a tribute to human ingenuity.

  14. Adhesive capsulitis: review of imaging and treatment

    International Nuclear Information System (INIS)

    Harris, Guy; Bou-Haider, Pascal; Harris, Craig

    2013-01-01

    Adhesive capsulitis is one of the most common conditions affecting the shoulder; however, early clinical diagnosis can be challenging. Treatment is most effective when commenced prior to the onset of capsular thickening and contracture; consequently, the role of imaging is increasing. The aim of this review is to demonstrate the typical imaging appearances of adhesive capsulitis and to examine some of the evidence regarding each of these imaging modalities. An evaluation of the various management options available to the clinician is also presented.

  15. Radioactive gas-containing polymeric capsule

    International Nuclear Information System (INIS)

    Winchell, H.S.; Lewis, R.E.

    1975-01-01

    A disposable ventilation study system for dispensing a single patient dosage of gaseous radioisotopes to patients for pulmonary function studies is disclosed. A gas impermeable capsule encloses the gaseous radioisotope and is stored within a radioactivity shielding body of valve means which shears the capsule to dispense the radioisotope to the patient. A breathing bag receives the patient's exhalation of the radioisotope and permits rebreathing of the radioisotope by the patient. 18 claims, 7 drawing figures

  16. A Class I (Senofilcon A) Soft Contact Lens Prevents UVB-Induced Ocular Effects, Including Cataract, in the Rabbit In Vivo

    Science.gov (United States)

    Lin, Li-Ren; Leverenz, Victor R.; Dang, Loan

    2011-01-01

    Purpose. UVB radiation from sunlight is known to be a risk factor for human cataract. The purpose in this study was to investigate the ability of a class I UV-blocking soft contact lens to protect against UVB-induced effects on the ocular tissues of the rabbit in vivo. Methods. Eyes of rabbits were exposed to UVB light for 30 minutes (270–360 nm, peak at 310 nm, 1.7 mW/cm2 on the cornea). Eyes were irradiated in the presence of either a UV-blocking senofilcon A contact lens, a minimally UV-blocking lotrafilcon A contact lens, or no contact lens at all. Effects on the cornea and lens were evaluated at various times after exposure. Results. Eyes irradiated with no contact lens protection showed corneal epithelial cell loss plus lens epithelial cell swelling, vacuole formation, and DNA single-strand breaks, as well as lens anterior subcapsular opacification. The senofilcon A lens protected nearly completely against the UVB-induced effects, whereas the lotrafilcon A lens showed no protection. Conclusions. The results indicate that use of a senofilcon A contact lens is beneficial in protecting ocular tissues of the rabbit against the harmful effects of UVB light, including photokeratitis and cataract. PMID:21421866

  17. A course in lens design

    CERN Document Server

    Velzel, Chris

    2014-01-01

    A Course in Lens Design is an instruction in the design of image-forming optical systems. It teaches how a satisfactory design can be obtained in a straightforward way. Theory is limited to a minimum, and used to support the practical design work. The book introduces geometrical optics, optical instruments and aberrations. It gives a description of the process of lens design and of the strategies used in this process. Half of its content is devoted to the design of sixteen types of lenses, described in detail from beginning to end. This book is different from most other books on lens design because it stresses the importance of the initial phases of the design process: (paraxial) lay-out and (thin-lens) pre-design. The argument for this change of accent is that in these phases much information can be obtained about the properties of the lens to be designed. This information can be used in later phases of the design. This makes A Course in Lens Design a useful self-study book, and a suitable basis for an intro...

  18. Gabor lens theory

    International Nuclear Information System (INIS)

    Irani, A.A.

    1978-01-01

    The principle of using the space charge of an electron cloud to focus ion beams was first proposed by Gabor. Electrons are to be confined radially by means of an axial magnetic field B/sub z/ and axially by means of externally applied electric fields E/sub z/. An ion beam of charge density n/sub i/ much less than n/sub e/, the electron charge density can then be focused by the radial electric field set up by the electron cloud. The case considered here is that of a hollow cylindrical conductor charged to a potential +V with grounded rings on either side to set up the axial E/sub z/ field. A solenoid wound around the central conductor supplies the B/sub z/ field. Theoretical calculations are carried out for n/sub e/ maximum as a function of B/sub z/ due to radial confinement and V due to axial confinement and the focal length of the Gabor Lens is calculated

  19. Congenital anterior urethral diverticulum

    International Nuclear Information System (INIS)

    Jung, Hyun Sub; Chung, Young Sun; Suh, Chee Jang; Won, Jong Jin

    1985-01-01

    Two cases of congenital anterior urethral diverticular which have occurred in a 4 year old and one month old boy are presented. Etiology, diagnostic procedures, and its clinical results are briefly reviewed

  20. Anterior knee pain

    Science.gov (United States)

    ... thighbone where the kneecap normally rests is too shallow. You have flat feet. Anterior knee pain is ... the principles of the Health on the Net Foundation (www.hon.ch). The information provided herein should ...

  1. [Contact lens related corneal ulcers: clinical, microbiological and therapeutic features].

    Science.gov (United States)

    Benhmidoune, L; Bensemlali, A; Bouazza, M; Karami, R; El Mansouri, H; El Belhadji, M; Rachid, R; Chakib, A; Amraoui, A

    2013-09-01

    Corneal ulcers in contact lens wearers are becoming more common, and can sometimes lead to severe complications. The purpose of this study is to define the epidemiological, clinical, microbiological and therapeutic considerations of these ulcers within the above context. We conducted an uncontrolled, descriptive, retrospective study of 51 patients presenting with contact lens related corneal ulcers to the ophthalmology department of the August 20, 1953 Hospital in Casablanca between January 2009 and January 2012. The average age of our patients was 22 years, with a gender ratio of 7.5 female to male. General risk factors (diabetes and tuberculosis) were found in 17.5% of cases. The average length of hospital stay was 15 days. Of our patients, 58.8% wore cosmetic contact lenses and 41.18% wore therapeutic contact lenses. Mean duration prior to consultation was 5 days. The predominant clinical signs were eye pain and redness, with a decrease in visual acuity worse than 1/10 in 82.3% of patients. In 70.6% of cases, the ulcer was central. The average size was 4.3mm. An anterior chamber reaction was found in 47.1%. Corneal bacterial cultures were positive in 47.8%. Pathogens found were Staphylococcus aureus, Pseudomonas aeruginosa and Acanthamœba. Contact lens and solution cultures were positive in 73.6% of cases. Outcomes were favorable with local and systemic antibiotic treatment adapted to microbiological results in only 41.2% of cases. In the remaining patients, significant secondary opacities persisted. Cosmetic and therapeutic contact lens wear is a major cause of corneal ulcer. Delayed consultation results in severe sequelae with persistently decreased visual acuity. The ophthalmologist plays an important role in preventing complications of contact lens wear, through better hygiene instruction and follow-up of his or her patients. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  2. Identifying anterior segment crystals.

    OpenAIRE

    Hurley, I W; Brooks, A M; Reinehr, D P; Grant, G B; Gillies, W E

    1991-01-01

    A series of 22 patients with crystals in the anterior segment of the eye was examined by specular microscopy. Of 10 patients with hypermature cataract and hyperrefringent bodies in the anterior chamber cholesterol crystals were identified in four patients and in six of the 10 in whom aspirate was obtained cholesterol crystals were demonstrated in three, two of these having shown crystals on specular microscopy. In 10 patients with intracorneal crystalline deposits, cholesterol crystals were f...

  3. Correlations between refractive error and biometric parameters in human eyes using the LenStar 900.

    Science.gov (United States)

    O'Donnell, Clare; Hartwig, Andreas; Radhakrishnan, Hema

    2011-02-01

    To investigate the relationship between refractive error and ocular biometry in healthy subjects using a new optical low coherence reflectometry device. Biometric measurements were obtained with a LenStar LS 900 (Haag Streit, Switzerland) on one eye of 70 phakic subjects (mean ± SD age; 29 ± 9 years). Forty myopes and 30 non-myopes (best sphere range -9.63 D to +0.63 D) were included. Outcome measures were compared for the two groups using one way between groups ANOVA. These included; keratometry, central corneal thickness, iris width, anterior chamber depth, pupil diameter, lens thickness, axial length and retinal thickness. No mydriatic or cycloplegic agents were used. There were significant differences between groups for keratometry readings (p = 0.021 and p = 0.038 for steep and flat k readings respectively), anterior chamber depth (p = 0.001), lens thickness (p = 0.026) and axial length (pbiometric parameters assessed and provides information about the relationships between these biometric parameters and age. The results, coupled with a unique ability to image and analyse the ocular structures non-invasively make the LenStar a promising new instrument for ocular evaluation in research and clinical practice. Copyright © 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  4. TGF-β1 serum concentrations and receptor expressions in the lens capsular of dogs with diabetes mellitus

    OpenAIRE

    Stephan Neumann; Jens Linek; Gerhard Loesenbeck; Julia Schüttler; Sonja Gaedke

    2017-01-01

    Tissue fibrosis as complication of diabetes mellitus is known in humans. Because TGF-?1induces fibrosis and is elevated in humans suffering from diabetes mellitus we measured this growth factor in serum of dogs with diabetes mellitus and compared it with healthy dogs and those with fibrotic diseases. Further we measured the expression of TGF-?1receptor on lens capsule to investigate possible association between diabetes mellitus and cataract associated alterations. TGF-?1 was measured in seru...

  5. Effect of four different intraocular lenses on posterior capsule opacification.

    Science.gov (United States)

    Duman, Rahmi; Karel, Fatih; Özyol, Pelin; Ateş, Can

    2015-01-01

    To evaluate the impact of 4 different intraocular lenses (IOLs) on posterior capsule opacification (PCO) by comparing the neodymium: yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy rates. This retrospective study included 4970 eyes of 4013 cataract patients who underwent phacoemulsification and IOL implantation between January 2000 and January 2008 by the same surgeon at one clinic. Four different IOLs were assessed. The outcome parameter was the incidence of Nd:YAG laser posterior capsulotomies. An Nd:YAG laser posterior capsulotomy was performed in 153 (3.07%) of the 4970 eyes. The mean follow-up time was 84mo for all of the IOL groups. The percentage of eyes developing PCO was significantly greater for the acrylic hydrophilic IOLs than for the hydrophobic IOLs, although eyes with acrylic hydrophilic IOLs did not require Nd:YAG laser capsulotomy as soon as eyes with acrylic hydrophobic IOLs. There was no difference between the long-term PCO rates when 1- and 3-piece acrylic hydrophobic IOLs were compared or when IOLs made of the same material but with different haptic angles were compared. In this study, eyes with acrylic hydrophilic IOLs were more likely to develop PCO than those with acrylic hydrophobic IOLs. The lens design (1-piece versus 3-piece and varying haptic angles) did not affect the PCO rate.

  6. Evaluation of Adhesive Capsulitis of the Shoulder With Fat-Suppressed T2-Weighted MRI: Association Between Clinical Features and MRI Findings.

    Science.gov (United States)

    Park, Sunghoon; Lee, Doo-Hyung; Yoon, Seung-Hyun; Lee, Hyun Young; Kwack, Kyu-Sung

    2016-07-01

    The purpose of this study was to examine the association between clinical features and MRI findings in adhesive capsulitis of the shoulder. This study included 103 patients (41 men, 62 women) with adhesive capsulitis. The MRI findings were correlated with pain intensity, range of motion, and clinical stage. Joint capsule edema in the axillary recess, extracapsular edema, obliteration of the subcoracoid fat triangle, and effusion in the long head biceps tendon sheath were assessed by two radiologists using fat-suppressed T2-weighted images. Joint capsule thickness in the axillary recess and degree of external rotation during MRI were also measured. Intraclass correlation coefficient and kappa values were obtained. Associations between MRI findings and clinical features were assessed by statistical analyses. Anterior extracapsular edema was associated with range of motion on external rotation and abduction (p capsule edema in the humeral portion of the axillary recess was associated with range of motion on external rotation (p = 0.01). Joint capsule thickness in the humeral portion of the axillary recess and height of the axillary recess were associated with pain intensity (p capsule edema in the humeral portion of the axillary recess and obliteration of the subcoracoid fat triangle were significantly more common in the early stages of adhesive capsulitis (p capsule thickness in the humeral portion of the axillary recess at stage 1 (4.67 ± 1.73 mm) was significantly different from the thickness at the later stages (stage 2, 3.73 ± 1.49 mm; stages 3 and 4, 3.67 ± 1.44 mm) (p adhesive capsulitis.

  7. An MRI study of symptomatic adhesive capsulitis.

    Science.gov (United States)

    Zhao, Wen; Zheng, Xiaofeng; Liu, Yuying; Yang, Wenlu; Amirbekian, Vardan; Diaz, Luis E; Huang, Xudong

    2012-01-01

    Appilication of MR imaging to diagnose Adhesive Capsulitis (AC) has previously been described. However, there is insufficient information available for the MRI analysis of AC. This study is to describe and evaluate the pathomorphology of the shoulder in Asian patients with AC compared to healthy volunteers. 60 Asian patients with clinically diagnosed AC and 60 healthy volunteers without frozen shoulder underwent MRI of the shoulder joint. All subjects who were age- and sex-matched control ones underwent routine MRI scans of the affected shoulder, including axial, oblique coronal, oblique sagittal T1WI SE and coronal oblique T2WI FSE sequences. Significant abnormal findings were observed on MRI, especially at the rotator cuff interval. The coracohumeral ligament (CHL), articular capsule thickness in the rotator cuff interval as well as the fat space under coracoid process were evaluated. MRI showed that patients with adhesive capsulitis had a significantly thickened coracohumeral ligament and articular capsule in the rotator cuff interval compared to the control subjects (4.2 vs. 2.4 mm, 7.2 vs. 4.4 mm; padhesive capsulitis compared with control subjects (73% vs. 13%, 26% vs. 1.6%; padhesive capsulitis than in control subjects. With regards to the inter-observer variability, two MR radiologists had an excellent kappa value of 0.86. MRI can be used to show characteristic findings in diagnosing AC. Thickening of the CHL and the capsule at the rotator cuff interval and complete obliteration of the fat triangle under the coracoid process have been shown to be the most characteristic MR findings seen with AC.

  8. An MRI study of symptomatic adhesive capsulitis.

    Directory of Open Access Journals (Sweden)

    Wen Zhao

    Full Text Available BACKGROUND: Appilication of MR imaging to diagnose Adhesive Capsulitis (AC has previously been described. However, there is insufficient information available for the MRI analysis of AC. This study is to describe and evaluate the pathomorphology of the shoulder in Asian patients with AC compared to healthy volunteers. METHODOLOGY/PRINCIPAL FINDINGS: 60 Asian patients with clinically diagnosed AC and 60 healthy volunteers without frozen shoulder underwent MRI of the shoulder joint. All subjects who were age- and sex-matched control ones underwent routine MRI scans of the affected shoulder, including axial, oblique coronal, oblique sagittal T1WI SE and coronal oblique T2WI FSE sequences. Significant abnormal findings were observed on MRI, especially at the rotator cuff interval. The coracohumeral ligament (CHL, articular capsule thickness in the rotator cuff interval as well as the fat space under coracoid process were evaluated. MRI showed that patients with adhesive capsulitis had a significantly thickened coracohumeral ligament and articular capsule in the rotator cuff interval compared to the control subjects (4.2 vs. 2.4 mm, 7.2 vs. 4.4 mm; p<0.05. Partial or complete obliteration of the subcoracoid fat triangle was significantly more frequent in patients with adhesive capsulitis compared with control subjects (73% vs. 13%, 26% vs. 1.6%; p<0.001. Synovitis-like abnormality around the long biceps tendon was significantly more common in patients with adhesive capsulitis than in control subjects. With regards to the inter-observer variability, two MR radiologists had an excellent kappa value of 0.86. CONCLUSIONS/SIGNIFICANCE: MRI can be used to show characteristic findings in diagnosing AC. Thickening of the CHL and the capsule at the rotator cuff interval and complete obliteration of the fat triangle under the coracoid process have been shown to be the most characteristic MR findings seen with AC.

  9. RETAINED STONE PIECE IN ANTERIOR CHAMBER

    Directory of Open Access Journals (Sweden)

    ZvornicaninJasmin, Nadarevic-VodencarevicAmra

    2015-04-01

    Full Text Available ABSTRACT We read with interest the article by Surekha et al. regarding the retained stone piece in anterior chamber. Similar to the results of previous studies, the authors found that delayed intraocular foreign body (IOFB management can result in good visual outcome without an apparent increased risk of endophthalmitis or other deleterious side effects. However, the authors failed to explain the exact reason for the diminution of vision in patients left eye. It is unclear what the uncorrected visual acuity was and what kind of correction was used, more precisely type and amount of cylinder, given the presence of the corneal opacity. Since the size of the IOFB is approximately 4x4x1mm, significant irido-corneal angle changes resulting in intraocular pressure raise and optic nerve head damage can be expected. Traumatic glaucoma following open globe injury can occur in 2.7 to 19% of cases, with several risk factors associated with glaucoma development (advanced age, poor visual acuity at presentation,perforating rather than penetrating ocular injury,lens injury, presence of vitreous hemorrhage and presence of an IOFB. Earlier reportsof latetraumaticoptic neuropathy onset, even after several years, indicate that this possibility cannot be completely ruled out too. Therefore, repeated intraocular pressure measurements, gonioscopy, pupillary reaction assessment, together with through posterior segment examination including visual field and optical coherence tomography examinations can be useful in determining the possible optic nerve damage as one of the possible reasons for visual acuity reduction. The authors did not suggest any operative treatment at this time. However, it should bear in mind that the inert anterior chamber IOFB could be a risk factor for non-infectious endophthalmitis development even after many years. Also, long term retained anterior chamber foreign body leads to permanent endothelial cell loss and can even result in a corneal

  10. Foreign Body Embedded in Anterior Chamber Angle

    Directory of Open Access Journals (Sweden)

    Shmuel Graffi

    2012-01-01

    Full Text Available Introduction. We present a case of a metallic foreign body embedded in the anterior chamber angle. After standing in close proximity to a construction worker breaking a tile, a 26-year-old woman using soft contact lens for the correction of mild myopia presented to emergency department for evaluation of a foreign body sensation of her right eye. Methods and Results. Diagnosis was confirmed by gonioscopic examination and a noncontrast CT scan of head and orbits. The foreign body was removed by an external approach without utilizing a magnet. The patient's final outcome was favorable. Discussion. The above is a rare clinical situation, which is impossible to detect on slit-lamp examination without a gonioscopic view. Proper imaging and a specific management are mandatory in order to achieve favorable outcome.

  11. Determination of absorbed dose to the lens of eye from external sources

    International Nuclear Information System (INIS)

    Chen Lishu

    1993-01-01

    The methods of determining absorbed dose distributions in human eyeball by means of the experiments and available theories have been reported. A water phantom was built up. The distributions of beta dose were measured by an extrapolation ionization chamber at some depths corresponding to components of human eyeball such as cornea, sclera, anterior chamber and the lens of eye. The ratios among superficial absorbed dose (at 0.07 mm) and average absorbed doses at the depths 1,2,3 mm are obtained. They can be used for confining the deterministic effects of superficial tissues and organs such as the lens of eye for weakly penetrating radiations

  12. Correction effect of phakic posterior chamber implantable contact lens implantation on high myopia

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2018-02-01

    Full Text Available AIM: To analyze the clinical efficacy of phakic posterior chamber implantable contact lens(ICLimplantation on high myopia patients. METHODS: Thirty-four patients(68 eyeswho checked and diagnosed as high myopia in our hospital from June 2014 to June 2015 were selected as the clinical research subjects, and all the patients were given phakic posterior chamber intraocular lens implantation treatment. The diopter, visual acuity recovery, central anterior chamber depth, corneal endothelial cell count, and intraocular pressure after treatment were observed. RESULTS: The equivalent spherical refraction, central anterior chamber depth, uncorrected visual acuity and best corrected visual acuity recovery at 1, 3 and 6mo, 1 and 2a after treatment were better than those before treatment, and the differences were statistically significant(PP>0.05. There were no significant differences in uncorrected visual acuity, best corrected visual acuity, equivalent spherical refraction and central anterior chamber depth at 1, 3mo and 1 and 2a after treatment(P>0.05. CONCLUSION: The application of phakic posterior chamber intraocular lens implantation for the treatment of high myopia patients can improve the equivalent spherical refraction and central anterior chamber depth, improve uncorrected visual acuity, meanwhile, it has less effect on the patient's intraocular pressure and corneal endometrial cells, the effect maintenance and safety is better which meet their expectations.

  13. [Zebrafish-a new animal models of anterior segment embryonic development and diseases basic research].

    Science.gov (United States)

    Hao, Yong-na; Wei, Rui-hua; Zhao, Shao-zhen

    2012-01-01

    In recent years, zebrafish has become ideal animal models of human disease with its unique characteristics, such as small body, fecundity, fast development and growth, embryo transparency, and so on. Furthermore, the structure and gene of zebrafish eye are highly conservative with human eye, which make ophthalmologists to pay close attention to zebrafish. This review focus on the studies and applications on zebrafish embryonic development of anterior segment, including the morphogenesis of cornea, lens and anterior chamber, and diseases of anterior segment (corneal diseases, cataract, glaucoma).

  14. [Contact lens care and maintenance].

    Science.gov (United States)

    Bloise, L

    2017-04-01

    All contact lenses with replacement schedules longer than daily must be maintained. At each step of their use, the lenses may be contaminated. Contact lens solutions perform the essential functions of cleaning, decontaminating and preserving the lenses to prevent infectious problems and improve wearing comfort. Contact lens contamination essentially comes from hands, cleaning solutions, cases, water and the environment. The pathogenic microorganisms are mainly Gram-negative bacteria, fungi and amoebae. Contact lens deposits may or may not have an organic origin. Their presence increases the risk of infection because they serve as a nutrient matrix for microbes, and they are responsible for wearing discomfort. Contact lens solutions differ in their composition, their mechanism of action and the concentration of the various agents. To prescribe the best lens care system to each wearer and for each material, it is necessary to be very familiar with them. Maintenance is the main cause of discomfort with contact lenses, either through improper use, solution-material incompatibility, or a reaction of the wearer to the components. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. A medieval fallacy: the crystalline lens in the center of the eye

    Directory of Open Access Journals (Sweden)

    Leffler CT

    2016-04-01

    Full Text Available Christopher T Leffler,1 Tamer M Hadi,2 Akrithi Udupa,1 Stephen G Schwartz,3 Daniel Schwartz1 1Department of Ophthalmology, Virginia Commonwealth University, Richmond, VA, 2Graduate School of Medicine, University of Tennessee Medical Center, Knoxville, TN, 3Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA Objective: To determine whether, as most modern historians have written, ancient Greco-Roman authors believed the crystalline lens is positioned in the center of the eye. Background: Historians have written that statements about cataract couching by Celsus, or perhaps Galen of Pergamon, suggested a centrally located lens. Celsus specifically wrote that a couching needle placed intermediate between the corneal limbus and the lateral canthus enters an empty space, presumed to represent the posterior chamber. Methods: Ancient ophthalmic literature was analyzed to understand where these authors believed the crystalline lens was positioned. In order to estimate where Celsus proposed entering the eye during couching, we prospectively measured the distance from the temporal corneal limbus to the lateral canthus in 30 healthy adults. Results: Rufus of Ephesus and Galen wrote that the lens is anterior enough to contact the iris. Galen wrote that the lens equator joins other ocular structures at the corneoscleral junction. In 30 subjects, half the distance from the temporal corneal limbus to the lateral canthus was a mean of 4.5 mm (range: 3.3–5.3 mm. Descriptions of couching by Celsus and others are consistent with pars plana entry of the couching needle. Anterior angulation of the needle would permit contact of the needle with the lens. Conclusion: Ancient descriptions of anatomy and couching do not establish the microanatomic relationships of the ciliary region with any modern degree of accuracy. Nonetheless, ancient authors, such as Galen and Rufus, clearly understood that the lens is located anteriorly

  16. Scaling effects in spiral capsule robots.

    Science.gov (United States)

    Liang, Liang; Hu, Rong; Chen, Bai; Tang, Yong; Xu, Yan

    2017-04-01

    Spiral capsule robots can be applied to human gastrointestinal tracts and blood vessels. Because of significant variations in the sizes of the inner diameters of the intestines as well as blood vessels, this research has been unable to meet the requirements for medical applications. By applying the fluid dynamic equations, using the computational fluid dynamics method, to a robot axial length ranging from 10 -5 to 10 -2  m, the operational performance indicators (axial driving force, load torque, and maximum fluid pressure on the pipe wall) of the spiral capsule robot and the fluid turbulent intensity around the robot spiral surfaces was numerically calculated in a straight rigid pipe filled with fluid. The reasonableness and validity of the calculation method adopted in this study were verified by the consistency of the calculated values by the computational fluid dynamics method and the experimental values from a relevant literature. The results show that the greater the fluid turbulent intensity, the greater the impact of the fluid turbulence on the driving performance of the spiral capsule robot and the higher the energy consumption of the robot. For the same level of size of the robot, the axial driving force, the load torque, and the maximum fluid pressure on the pipe wall of the outer spiral robot were larger than those of the inner spiral robot. For different requirements of the operating environment, we can choose a certain kind of spiral capsule robot. This study provides a theoretical foundation for spiral capsule robots.

  17. Video capsule endoscopy of the small bowel.

    Science.gov (United States)

    Eliakim, Rami

    2013-03-01

    Small bowel capsule endoscopy (SBCE) was introduced 13 years ago by Given Imaging (Yokneam, Israel). It has become one of the most important investigational tools of the small bowel. The capsule is swallowed with water after a 12 h fast, propelled via peristalsis through the gastrointestinal tract and excreted naturally. A nonvideo patency capsule was developed to confirm functional patency of the gastrointestinal tract. Four additional companies have introduced competitive small bowel video capsules, some of which are Food and Drug Admistration (FDA) approved. Due to the easiness of the procedure, SBCE has become a first-line tool to detect small bowel abnormalities. The main indications for SBCE include obscure gastrointestinal bleeding, suspected Crohn's disease, small bowel tumors and practically any abnormal small bowel imaging. New indications are emerging like small bowel motility and monitoring of drug therapy and mucosal healing. The present review will describe the available capsules in the market, the procedure itself, present indications and future expectations. It will focus on the PillCam SB of Given Imaging as it is the one on which most of the literature is written. Over the past 10 years, SBCE has become a routine, first-line investigational tool of many small bowel pathologies.

  18. Clinical evaluation of arthroscopic treatment of shoulder adhesive capsulitis

    Directory of Open Access Journals (Sweden)

    Alberto Naoki Miyazaki

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the results of arthroscopic releases performed in patients with adhesive capsulitis refractory to conservative treatment. METHODS: This was a retrospective study, conducted between 1996 and 2012, which included 56 shoulders (52 patients that underwent surgery; 38 were female, and 28 had the dominant side affected. The mean age was 51 (29-73 years. The mean follow-up was 65 (12-168 months and the mean preoperative time was 8.9 (2-24 months. According to Zukermann's classification, 23 cases were considered primary and 33 secondary. With the patient in the lateral decubitus position, circumferential release of the joint capsule was performed: joint debridement; rotator interval opening; coracohumeral ligament release; anterior, posterior, inferior, and finally antero-inferior capsulotomy. A subscapularis tenotomy was performed when necessary. All patients underwent intense physical therapy in the immediate postoperative period. In 33 shoulders, an interscalene catheter was implanted for anesthetic infusion. Functional results were evaluated by the UCLA criteria. RESULTS: Improved range of motion was observed: mean increase of 45° of elevation, 41° of external rotation and eight vertebral levels of medial rotation. According to the UCLA score excellent results were obtained in 25 (45% patients; good, in 24 (45%; fair, in two (3%; and poor, in two (7%. Patients who had undergone inferior capsulotomy achieved better results. Only 8.8% of patients who used the anesthetic infusion catheter underwent postoperative manipulation. Seven patients had complications. CONCLUSION: There was improvement in pain and range of motion. Inferior capsulotomy leads to better results. The use of the interscalene infusion catheter reduces the number of re-approaches.

  19. CORR®ORS Richard A. Brand Award: Clinical Trials of a New Treatment Method for Adhesive Capsulitis.

    Science.gov (United States)

    Badalamente, Marie A; Wang, Edward D

    2016-11-01

    Conservative and even surgical management of adhesive capsulitis often is prolonged and painful. Management of adhesive capsulitis is lacking evidence-based controlled clinical trials. We asked: (1) Does a collagenase clostridium histolyticum (CCH) injection lyse shoulder capsule collagen in adhesive capsulitis and at what dose? (2) Can a shoulder capsule injection be administered extraarticularly? (3) Do CCH injections result in better scores for pain and function than can be achieved with physical therapy among patients with adhesive capsulitis? First, 60 patients with adhesive capsulitis were evaluated by clinical examination. To make the diagnosis of adhesive capsulitis, a patient had to have restricted active ROM of at least 60° in total active ROM in the affected shoulder compared with the unaffected contralateral shoulder; with the scapula stabilized, external rotation with the elbow at the side was a very important determinant. Patients were randomized to receive a single injection of 0.5 mL placebo or 0.145, 0.29, or 0.58 mg CCH. All 60 patients were followed up at 30 days. After that, if patients did not attain treatment thresholds they were eligible for up to five open-label 0.58-mg collagenase injections. For the longer-term followup in the open-label phase, 53 patients (83%) were followed to 12 months, 46 (77%) for 24 months, 36 (60%) for 36 months, 37 (62%) for 48 months, and 25 (42%) for 60 months. The extraarticular injection was directed at the anterior shoulder capsule with the patient in the supine position. To prove that these injections could be delivered reliably to the anterior shoulder capsule extraarticularly, the next study involved volunteers without adhesive capsulitis, in which 10 volunteers received a 10-mL injection of normal saline under ultrasound guidance. Finally, to determine the efficacy and dosing of CCH, four cohorts of 10 patients received up to three ultrasound-guided injections separated by 21 days. These injections were

  20. The SNAP Strong Lens Survey

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, P.

    2005-01-03

    Basic considerations of lens detection and identification indicate that a wide field survey of the types planned for weak lensing and Type Ia SNe with SNAP are close to optimal for the optical detection of strong lenses. Such a ''piggy-back'' survey might be expected even pessimistically to provide a catalogue of a few thousand new strong lenses, with the numbers dominated by systems of faint blue galaxies lensed by foreground ellipticals. After sketching out our strategy for detecting and measuring these galaxy lenses using the SNAP images, we discuss some of the scientific applications of such a large sample of gravitational lenses: in particular we comment on the partition of information between lens structure, the source population properties and cosmology. Understanding this partitioning is key to assessing strong lens cosmography's value as a cosmological probe.

  1. Automated Fresnel lens tester system

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, G.S.

    1981-07-01

    An automated data collection system controlled by a desktop computer has been developed for testing Fresnel concentrators (lenses) intended for solar energy applications. The system maps the two-dimensional irradiance pattern (image) formed in a plane parallel to the lens, whereas the lens and detector assembly track the sun. A point detector silicon diode (0.5-mm-dia active area) measures the irradiance at each point of an operator-defined rectilinear grid of data positions. Comparison with a second detector measuring solar insolation levels results in solar concentration ratios over the image plane. Summation of image plane energies allows calculation of lens efficiencies for various solar cell sizes. Various graphical plots of concentration ratio data help to visualize energy distribution patterns.

  2. Compliance among soft contact lens wearers.

    Science.gov (United States)

    Kuzman, Tomislav; Kutija, Marija Barisić; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurisić, Darija; Skegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-12-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in different aspects of lens care handling and wearing habits. In our research 50 asymptomatic lens wearers filled out a questionnaire containing demographic data, lens type, hygiene and wearing habits, lenses and lens care system replacement schedule and self-evaluation of contact lens handling hygiene. We established criteria of compliance according to available manufacturer's recommendations, prior literature and our clinical experience. Only 2 (4%) of patients were fully compliant SCL wearers. The most common non-compliant behaviours were insufficient lens solution soaking time (62%), followed by failure to daily exchange lens case solution and showering while wearing lenses. 44% of patients reported storing lenses in saline solution. Mean lens storage case replacement was 3.6 months, with up to 78% patients replacing lens case at least once in 3 months. Average grade in self evaluating level of compliance was very good (4 +/- 0.78) (from 1-poor level of hygiene to 5-great level of hygiene). Lens wearers who reported excessive daily lens wear and more than 10 years of lens wearing experience were also found to be less compliant with other lens system care procedures. (t = -2.99, df=47, p lens system maintenance steps. Most common non-compliant behaviours were the ones that are crucial for maintaining lens sterility and preventing infection. Despite the low objective compliance rate, self grading was relatively high. Therefore, these results indicate the need for patient

  3. Antioxidant status of dog aqueous humor after extracapsular lens extraction

    Directory of Open Access Journals (Sweden)

    Barros P.S.M.

    2003-01-01

    Full Text Available We determined the antioxidant status of the aqueous humor after extracapsular lens extraction in 14 mongrel dogs weighing about 10 kg. The animals were examined by slit lamp biomicroscopy, applanation tonometry and indirect ophthalmoscopy. One eye was submitted to conventional extracapsular lens extraction and the other was used as control. Samples of aqueous humor were obtained by anterior chamber paracentesis before and at days 1, 2, 3, 7 and 15 after surgery. Total antioxidant status was determined as the capacity of aqueous humor to inhibit free radical generation by 2,2-azobis(2-amidopropane chlorine. Ascorbic acid concentration was measured by HPLC with UV detection. Protein content was determined with the biuret reagent. Statistical analysis was performed by ANOVA followed by the Tukey-Kramer test. Protein concentration increased from 0.61 to 22 mg/ml 24 h after surgery. These levels were maintained and returned to normal at day 7. Total antioxidant capacity was reduced from 50 to about 30 min until day 3 and at day 7 it was equal to control. Ascorbic acid levels were reduced from 252 to about 110 µM and then returned to control values at day 15. Considering the importance of ascorbic acid concentration in aqueous humor for the maintenance of the antioxidant status of the anterior segment of the eye, the decrease of antioxidant defenses suggests that the surgical procedures promote an oxidative stress condition in the eye.

  4. Study of biological measurement parameters of anterior segment in primary acute angle-closure glaucoma

    Directory of Open Access Journals (Sweden)

    Jun-Jie Bian

    2015-02-01

    Full Text Available AIM:To investigate biological measurement parameters of anterior segment in acute angle-closure glaucoma(AACG.METHODS: Forty-six eyes of 46 patients with AACG and 52 eyes of 52 patients with shallow anterior chamber and 50 eyes of 50 normal individuals were examined. The parameters of anterior segment including chamber crowd rate(CCR, lens thickness(LT, lens position(LPand anterior chamber depth(ACDwere measured by A-ultrasound according to different ages in each group. The data were performed statistical analysis in three groups.RESULTS: In each age range group(≥50~59 years old, ≥60~69 years old, ≥70 years old, statistically significant differences in three groups(AACG, shallow anterior chamber group and the controlswere found in CCR, LT, LP, ACD(PPP>0.05between AACG and shallow anterior chamber group in each age range group.CONCLUSION: CCR can be used as the index of evaluating crowding state of anterior segment in AACG patients and the sensitivity is better than LT and LP.

  5. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma.

    Science.gov (United States)

    Wang, Rui; Bi, Chun-Chao; Lei, Chun-Ling; Sun, Wen-Tao; Wang, Shan-Shan; Dong, Xiao-Juan

    2014-01-01

    To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL) implantation. Non-comparative retrospective observational case series. 30 cases (30 eyes) of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi'an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs) were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations. The follow-up time was 11-36mo (21.4±7.13). Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL dislocation, and endophthalmitis. To take early treatment of traumatic lens

  6. Growth and optical development of the ocular lens of the squid (Sepioteuthis lessoniana).

    Science.gov (United States)

    Sivak, J G; West, J A; Campbell, M C

    1994-09-01

    Lens focal properties (spherical aberration), diameter and relative anterior/posterior proportions were measured photographically for Japanese squid (Sepioteuthis lessoniana) at ages 4-6 weeks, 7-9 weeks and 7-8 months. The measures involved photographing the refractive effects of lenses in a physiological solution, with and without an index matching fluid (polyvinylpyrroloidone solution), on a parallel array of fine helium-neon laser beams. Spherical aberration was determined from measurement of back vertex distance. Similar measurements were made on lenses from the eyes of cuttlefish (Sepia officinalis). The cephalopod lens develops as hemispheric halves from separate ectodermal sources. The posterior component contributes, on average, about 60% of axial lens diameter in S. lessoniana of all ages and 55% in S. officinalis. However, these proportions vary widely in both species. All lenses of both species show that spherical aberration is neutralized, although small variations in back vertex distance (positive and negative spherical aberration) were measured. Preliminary measures indicate that the refractive index distribution within the cephalopod lens varies in a manner reminiscent of teleost lenses. Squid lenses from animals 7-9 weeks of age were optimally corrected for spherical aberration. Some squid of this age, from a separate tank, showed a high incidence of cataract development. In each case, lens opacification was caused by deterioration of the posterior lens component.

  7. Semiautomated analysis of optical coherence tomography crystalline lens images under simulated accommodation.

    Science.gov (United States)

    Kim, Eon; Ehrmann, Klaus; Uhlhorn, Stephen; Borja, David; Arrieta-Quintero, Esdras; Parel, Jean-Marie

    2011-05-01

    Presbyopia is an age related, gradual loss of accommodation, mainly due to changes in the crystalline lens. As part of research efforts to understand and cure this condition, ex vivo, cross-sectional optical coherence tomography images of crystalline lenses were obtained by using the Ex-Vivo Accommodation Simulator (EVAS II) instrument and analyzed to extract their physical and optical properties. Various filters and edge detection methods were applied to isolate the edge contour. An ellipse is fitted to the lens outline to obtain central reference point for transforming the pixel data into the analysis coordinate system. This allows for the fitting of a high order equation to obtain a mathematical description of the edge contour, which obeys constraints of continuity as well as zero to infinite surface slopes from apex to equator. Geometrical parameters of the lens were determined for the lens images captured at different accommodative states. Various curve fitting functions were developed to mathematically describe the anterior and posterior surfaces of the lens. Their differences were evaluated and their suitability for extracting optical performance of the lens was assessed. The robustness of these algorithms was tested by analyzing the same images repeated times.

  8. Modeling internal stress distributions in the human lens: can opponent theories coexist?

    Science.gov (United States)

    Belaidi, A; Pierscionek, B K

    2007-08-03

    The effects of material properties and equatorial stretching forces on the stress distribution and shape profile of human lenses were investigated to see whether support could be found for either or both current theories of accommodation. Finite element analysis was used to create models using shape parameters and material properties from published data. Models were constructed for two lenses of different ages. Material properties were varied to show differences between models with a single elastic modulus and those with different moduli for the cortex and the nucleus. Two levels of stretching forces were applied at the equator. Comparisons between experimental and model profiles were made, and stress distribution patterns were constructed. In all models, stretching produces a flattening in the peripheral curvature of the lens. In the younger lens, model and experimental results show that central curvature at some points is steeper for stretched than for unstretched profiles. In the older lens, gradients are flatter at all central points for stretched model and experimental profiles compared to the unstretched profile. In all models, there is a region of higher stress distribution within the lens that corresponds with the position of an inflection point that appears on the anterior surface and, in the older lens, also on the posterior surface. The results show that equatorial stretching forces can produce shape changes in support of both current theories of accommodation depending on the lens age, shape, and applied force.

  9. Comparison of posterior capsule folds following intracapsular implantation of three types of intraocular lenses with different haptic design

    Directory of Open Access Journals (Sweden)

    Ling-Lin Zhang

    2018-04-01

    Full Text Available AIM: To compare the incidence of posterior capsule folds among different types of intraocular lens(IOLto determine risk factors of posterior capsule folds. METHODS:It was a retrospective study. We collected the cases in which the patients underwent phacoemulsification(PHACOand IOL implantation and at least one of the three types of IOL was implanted, including 2-haptic 3-piece IOLs(HOYA PY60AD, 4-haptic 1-piece IOLs(Bausch & Lomb AO, 2-haptic 1-piece IOLs(AMO Tecnis ZCB00. The posterior capsule folds were measured using slit lamp microscope 2d after the surgery. Information of patient's age, gender, length of ocular axis, intraocular pressure, types of IOL were recorded. Posterior capsule fold risk indicators were identified by using logistic regression analysis. RESULTS: One hundred eighty-seven patients(242 eyeshad been collected, including 80 eyes implanted with HOYA PY60AD IOLs, 81 eyes implanted with Bausch & Lomb AO IOLs, 81 eyes implanted with AMO Tecnis ZCB00 IOLs. The incidence of posterior capsule folds of patients implanted with HOYA PY60AD IOLs was significantly higher than those of patients implanted with AMO Tecnis ZCB00 IOLs(56.3% vs 38.3%, P=0.027. While the incidence of patients implanted with Bausch & Lomb AO IOLs was significantly lower than those of patients implanted with AMO Tecnis ZCB00 IOLs(14.8% vs 38.3%, P=0.001. Multi-factor logistics regression analysis demonstrated that independent risk factors were type of IOLs and length of ocular axis. Compared with AMO Tecnis ZCB00 IOLs, using HOYA PY60AD IOLs increased the risk of posterior capsule folds \\〖P=0.020, OR(95%CI=2.145(1.129,4.073\\〗, while using Bausch & Lomb AO IOLs reduced the risk \\〖P=0.001, OR(95%CI=0.274(0.127, 0.591\\〗. Shorter ocular axis might increase the risk of posterior capsule folds \\〖P=0.012, OR(95%CI=0.669(0.489, 0.915\\〗. CONCLUSION: Haptic design should be an important consideration in IOL design. Compared with AMO Tecnis ZCB00 IOLs

  10. The first capsule implosion experiments on Orion

    International Nuclear Information System (INIS)

    Garbett, W J; Horsfield, C J; Gales, S G; Leatherland, A E; Rubery, M S; Coltman, J E; Meadowcroft, A E; Rice, S J; Simons, A J; Woolhead, V E

    2016-01-01

    Direct drive capsule implosions are being developed on the Orion laser at AWE as a platform for ICF and HED physics experiments. The Orion facility combines both long pulse and short-pulse beams, making it well suited for studying the physics of alternative ignition approaches. Orion implosions also provide the opportunity to study aspects of polar direct drive. Limitations on drive symmetry from the relatively small number of laser beams makes predictive modelling of the implosions challenging, resulting in some uncertainty in the expected capsule performance. Initial experiments have been fielded to evaluate baseline capsule performance and inform future design optimization. Highly promising DD fusion neutron yields in excess of 10 9 have been recorded. Results from the experiments are presented alongside radiation-hydrocode modelling. (paper)

  11. Production of 131I gelatin capsules

    International Nuclear Information System (INIS)

    Freud, A.; Hirshfeld, N.; Canfi, A.; Melamud, Y.

    1997-01-01

    Radioiodine ( 131 I) hard-gelatin capsules are widely used for the diagnosis and treatment of various thyroid disorders. Until 1980 radioiodine was supplied by us as a liquid dosage. This proved to be a rather inconvenient form since it resulted in inaccurate dosing by the physicians and caused frequent contamination of the patients and the hospital personnel. In an attempt to overcome these problems we have designed and constructed a production facility for capsules in which 1311 is packaged. Because of the extreme precautions necessary in handling radioactive compounds, encapsulation of radioactive materials requires specifically designed production techniques, special instrumentation and unique quality control procedures that are not encountered in the standard capsule production processes in the pharmaceutical industry

  12. Chord length distribution for a compound capsule

    International Nuclear Information System (INIS)

    Pitřík, Pavel

    2017-01-01

    Chord length distribution is a factor important in the calculation of ionisation chamber responses. This article describes Monte Carlo calculations of the chord length distribution for a non-convex compound capsule. A Monte Carlo code was set up for generation of random chords and calculation of their lengths based on the input number of generations and cavity dimensions. The code was written in JavaScript and can be executed in the majority of HTML viewers. The plot of occurrence of cords of different lengths has 3 peaks. It was found that the compound capsule cavity cannot be simply replaced with a spherical cavity of a triangular design. Furthermore, the compound capsule cavity is directionally dependent, which must be taken into account in calculations involving non-isotropic fields of primary particles in the beam, unless equilibrium of the secondary charged particles is attained. (orig.)

  13. Capsule endoscopy—A mechatronics perspective

    Science.gov (United States)

    Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay

    2011-03-01

    The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.

  14. Computer-aided lens assembly

    Science.gov (United States)

    Tomlinson, Richard; Alcock, Rob; Petzing, Jon; Coupland, Jeremy

    2004-01-01

    We propose a computer-aided method of lens manufacture that allows assembly, adjustment, and test phases to be run concurrently until an acceptable level of optical performance is reached. Misalignment of elements within a compound lens is determined by a comparison of the results of physical ray tracing by use of an array of Gaussian laser beams with numerically obtained geometric ray traces. An estimate of misalignment errors is made, and individual elements are adjusted in an iterative manner until performance criteria are achieved. The method is illustrated for the alignment of an air-spaced doublet.

  15. Acanthamoeba keratitis. Contact lens and noncontact lens characteristics.

    Science.gov (United States)

    Chynn, E W; Lopez, M A; Pavan-Langston, D; Talamo, J H

    1995-09-01

    To identify potential differences in time to diagnosis and final visual outcome between contact lens and noncontact lens users with Acanthamoeba keratitis. Prior studies have shown early diagnosis and therapy to be related to outcome but have not analyzed differences among patients with and without contact lenses. A retrospective analysis of 11 consecutive cases (involving 13 eyes) of Acanthamoeba keratitis diagnosed at one institution over a 3-year period. Mean time to diagnosis was significantly longer in noncontact lens users versus those who wore contact lenses (mean, 5.8 versus 3.3 weeks). Fifty percent of patients who did not wear contact lenses had a poor outcome (visual acuity worse than 20/40 or penetrating keratoplasty) versus 14% of patients who wore contact lenses. Diagnoses were made later in patients without contact lenses, and these patients had a worse visual outcome than those with Acanthamoeba keratitis who wore contact lenses. All patients with unresponsive microbial keratitis, even those without contact lens use, should be evaluated for Acanthamoeba.

  16. AGE-RAGE interaction in the TGFβ2-mediated epithelial to mesenchymal transition of human lens epithelial cells.

    Science.gov (United States)

    Raghavan, Cibin T; Nagaraj, Ram H

    2016-08-01

    Basement membrane (BM) proteins accumulate chemical modifications with age. One such modification is glycation, which results in the formation of advanced glycation endproducts (AGEs). In a previous study, we reported that AGEs in the human lens capsule (BM) promote the TGFβ2-mediated epithelial-to-mesenchymal transition (EMT) of lens epithelial cells, which we proposed as a mechanism for posterior capsule opacification (PCO) or secondary cataract formation. In this study, we investigated the role of a receptor for AGEs (RAGE) in the TGFβ2-mediated EMT in a human lens epithelial cell line (FHL124). RAGE was present in FHL124 cells, and its levels were unaltered in cells cultured on either native or AGE-modified BM or upon treatment with TGFβ2. RAGE overexpression significantly enhanced the TGFβ2-mediated EMT responses in cells cultured on AGE-modified BM compared with the unmodified matrix. In contrast, treatment of cells with a RAGE antibody or EN-RAGE (an endogenous ligand for RAGE) resulted in a significant reduction in the TGFβ2-mediated EMT response. This was accompanied by a reduction in TGFβ2-mediated Smad signaling and ROS generation. These results imply that the interaction of matrix AGEs with RAGE plays a role in the TGFβ2-mediated EMT of lens epithelial cells and suggest that the blockade of RAGE could be a strategy to prevent PCO and other age-associated fibrosis.

  17. A case report of intraocular lens luxation with the capsular bag after vitrectomy.

    Science.gov (United States)

    Kawai, Kenji; Bando, Masayasu; Suzuki, Takahiro; Hayakawa, Kenji

    2004-04-01

    We experienced a case of intraocular lens (IOL) luxation with the capsular bag after vitrectomy. The case was a 66-year-old female in whom an IOL was implanted one year after surgery for giant tear retinal detachment using silicone oil. Four years after the implantation surgery, the patient suffered subluxation of the IOL with the capsular bag. Examinations of the luxated IOL with the capsular bag using a stereoscopic microscope confirmed the presence of silicone oil droplets between the capsule and the IOL. Adhesion of vitreous body residues was observed in the capsule. Luxation of the IOL was thought to be connected with chronic inflammation resulting from the use of silicone oil and repeated vitrectomy. In addition to examining pathological findings of luxated IOL, it would also be important in the future to identify the pathology of the capsular bag.

  18. Endoscopic placement of the small-bowel video capsule by using a capsule endoscope delivery device.

    Science.gov (United States)

    Holden, Jeremy P; Dureja, Parul; Pfau, Patrick R; Schwartz, Darren C; Reichelderfer, Mark; Judd, Robert H; Danko, Istvan; Iyer, Lalitha V; Gopal, Deepak V

    2007-05-01

    Capsule endoscopy performed via the traditional peroral route is technically challenging in patients with dysphagia, gastroparesis, and/or abnormal upper-GI (UGI) anatomy. To describe the indications and outcomes of cases in which the AdvanCE capsule endoscope delivery device, which has recently been cleared by the Food and Drug Administration, was used. Retrospective, descriptive, case series. Tertiary care, university hospital. We report a case series of 16 consecutive patients in whom the AdvanCE delivery device was used. The study period was May 2005 through July 2006. Endoscopic delivery of the video capsule to the proximal small bowel by using the AdvanCE delivery device. Indications, technique, and completeness of small bowel imaging in patients who underwent endoscopic video capsule delivery. The AdvanCE delivery device was used in 16 patients ranging in age from 3 to 74 years. The primary indications for endoscopic delivery included inability to swallow the capsule (10), altered UGI anatomy (4), and gastroparesis (2). Of the 4 patients with altered UGI anatomy, 3 had dual intestinal loop anatomy (ie, Bilroth-II procedure, Whipple surgery, Roux-en-Y gastric bypass) and 1 had a failed Nissen fundoplication. In all cases, the capsule was easily deployed without complication, and complete small intestinal imaging was achieved. Small patient size. Endoscopic placement of the Given PillCam by use of the AdvanCE delivery device was safe and easily performed in patients for whom capsule endoscopy would otherwise have been contraindicated or technically challenging.

  19. Subluxation of the crystalline lens: a no-ring approach.

    Science.gov (United States)

    Rodrigues, Antonio Carlos L; Trivedi, Rupal H; Wilson, M Edward

    2012-01-01

    To report the surgical technique and outcomes of a no-ring approach to posterior chamber intraocular lens (IOL) implantation in children and young adults with subluxation of the crystalline lens. A three-piece 5.5-mm hydrophobic acrylic IOL was implanted in which the optic and one haptic were inside the capsular bag and the other haptic was in the ciliary sulcus. The implantations were done in 13 eyes of 10 patients with lens subluxation. One haptic was fixated in the ciliary sulcus by passing it through an operculum-shaped opening in the capsular bag edge, made between 2 and 3 clock hours, clockwise from the middle point of the subluxated area. The mean age of the 10 patients was 12.61 ± 8.04 years and the mean follow-up was 21.38 ± 11.29 months. The mean preoperative and postoperative best-corrected visual acuity (BCVA) was 1.15 ± 0.58 and 0.37 ± 0.17 logarithm of the minimum angle of resolution, respectively, in 11 measured eyes. The postoperative BCVA was 20/40 or better in 4 eyes (36.36%), between 20/40 and 20/60 in 6 eyes (54.54%), and between 20/80 and 20/100 in 1 eye (9.09%). The BCVA improved in all eyes. Postoperative IOL decentration between 1.0 and 1.5 mm occurred in 3 of 13 eyes (23.08%). The results indicate that the no-ring technique allows centration of an IOL implanted into a subluxated capsular bag without using capsule tension rings. Copyright 2012, SLACK Incorporated.

  20. Lens parameters as predictors of intraocular pressure changes after phacoemulsification.

    Science.gov (United States)

    Moghimi, S; Abdi, F; Latifi, G; Fakhraie, G; Ramezani, F; He, M; Lin, S C

    2015-11-01

    To evaluate intraocular pressure (IOP) change after cataract surgery in non-glaucomatous eyes with narrow and open angles (OAs) and its relation to novel lens parameters measured by anterior segment optical coherence tomography (AS-OCT). University affiliated hospital, Farabi Eye Hospital, Tehran, Iran. Prospective interventional case series. In this prospective study, 85 non-glaucomatous eyes underwent phacoemulsification and lens implantation. Thirty-nine eyes had OAs and 46 eyes had narrow angles (NAs). IOP and biometric parameters were measured by AS-OCT preoperatively and 3 months after surgery. Change in IOP and its relation to biometric parameters, including lens vault (LV), anterior vault (AV), defined as the sum of the LV and the ACD, and relative LV (rLV), defined as the ratio of the LV to the AV, were evaluated. The main outcome measure was degree of IOP change after phacoemulsification. Of the 85 patients included in the analysis, 35 were male and 50 were female with an overall mean age of 62.2 ± 8.9 years. The average IOP reduction was -4.95 ± 2.26 mm Hg, from a preoperative mean of 17.12 ± 2.47 mm Hg, at 3 months after cataract surgery. The amount of IOP reduction was significantly greater in the NA compared with the OA group. In multivariate linear regression analysis, preoperative IOP and AV were significantly associated with IOP decrease (all ≤ 0.03). Cataract surgery results in IOP reduction in both OA and NA eyes. The amount of IOP reduction is related to AV.

  1. Capsule storage and density-analog techniques

    International Nuclear Information System (INIS)

    Paxton, H.C.

    1975-05-01

    Density-analog schemes for describing critical arrays of fissile units have a long history. They originated as methods for generalizing results of subcritical measurements on weapon capsules. Such measurements were needed to establish reasonably efficient rules for capsule storage. Although specific density-analog models have been improved throughout the years, they are now largely replaced by comprehensive tabulations of critical-lattice parameters. Certain simplified forms are still useful as convenient formulas for extrapolation or for gross sorting of safety features. (U.S.)

  2. Adhesive capsulitis: review of imaging and treatment.

    Science.gov (United States)

    Harris, Guy; Bou-Haidar, Pascal; Harris, Craig

    2013-12-01

    Adhesive capsulitis is one of the most common conditions affecting the shoulder; however, early clinical diagnosis can be challenging. Treatment is most effective when commenced prior to the onset of capsular thickening and contracture; consequently, the role of imaging is increasing. The aim of this review is to demonstrate the typical imaging appearances of adhesive capsulitis and to examine some of the evidence regarding each of these imaging modalities. An evaluation of the various management options available to the clinician is also presented. © 2013 The Royal Australian and New Zealand College of Radiologists.

  3. Treatment of adhesive capsulitis: a review

    Science.gov (United States)

    D’Orsi, Giovanni Maria; Via, Alessio Giai; Frizziero, Antonio; Oliva, Francesco

    2012-01-01

    Summary Adhesive capsulitis is a condition “difficult to define, difficult to treat and difficult to explain from the point of view of pathology”. This Codman’s assertion is still actual because of a variable nomenclature, an inconsistent reporting of disease staging and many types of treatment. There is no consensus on how the best way best to manage patients with this condition, so we want to provide an evidence-based overview regarding the effectiveness of conservative and surgical interventions to treat adhesive capsulitis. PMID:23738277

  4. Microbiological profile of anterior chamber aspirates following uncomplicated cataract surgery

    Directory of Open Access Journals (Sweden)

    Prajna N

    1998-01-01

    Full Text Available Anterior chamber aspirate cultures were done for 66 patients who underwent either an uncomplicated intracapsular cataract extraction, extracapsular cataract extraction with posterior-chamber intraocular lens implantation, or phacoemulsification with posterior-chamber intraocular lens implantation. The aspirate was obtained at the time of wound closure. The aspirates were immediately transferred to the microbiology laboratory where one drop of the aspirate was placed on a glass slide for gram stain, and the remainder was unequally divided and inoculated into blood agar, chocolate agar and thioglycolate broth. The cultures were incubated at 37° C with 5% CO2 and held for 5 days. Of 66 patients 4 (6%, had smear-positive anterior chamber aspirates. None of the aspirates showed any growth on any of the 3 culture media used. None of the eyes in the study developed endophthalmitis. This study concludes that there is no contamination of the anterior chamber by viable bacteria after cataract surgery, irrespective of the mode of intervention.

  5. Antioxidant Delivery Pathways in the Anterior Eye

    Directory of Open Access Journals (Sweden)

    Ankita Umapathy

    2013-01-01

    Full Text Available Tissues in the anterior segment of the eye are particular vulnerable to oxidative stress. To minimise oxidative stress, ocular tissues utilise a range of antioxidant defence systems which include nonenzymatic and enzymatic antioxidants in combination with repair and chaperone systems. However, as we age our antioxidant defence systems are overwhelmed resulting in increased oxidative stress and damage to tissues of the eye and the onset of various ocular pathologies such as corneal opacities, lens cataracts, and glaucoma. While it is well established that nonenzymatic antioxidants such as ascorbic acid and glutathione are important in protecting ocular tissues from oxidative stress, less is known about the delivery mechanisms used to accumulate these endogenous antioxidants in the different tissues of the eye. This review aims to summarise what is currently known about the antioxidant transport pathways in the anterior eye and how a deeper understanding of these transport systems with respect to ocular physiology could be used to increase antioxidant levels and delay the onset of eye diseases.

  6. A microcapillary lens for X-rays

    CERN Document Server

    Dudchik, Y I

    1999-01-01

    A new design of a compound refractive lens for X-rays is proposed. The lens is made as a set of glue microlenses placed in a glass capillary. The technique of lens fabrication is described. Results of ray tracing calculations for 8 and 15 keV photons are represented.

  7. Anterior cruciate ligament injury, reconstruction, and the optimization of outcome

    Directory of Open Access Journals (Sweden)

    James Philip Bliss

    2017-01-01

    Full Text Available Anterior cruciate ligament reconstruction (ACLR provides an established surgical intervention to control pathological tibiofemoral translational and rotational movement. ACLR is a safe and reproducible intervention, but there remains an underlying rate of failure to return to preinjury sporting activity levels. Postoperative pathological laxity and graft reinjury remain concerns. Previously, unrecognized meniscal lesions, disruption of the lateral capsule, and extracapsular structures offer potential avenues to treat and to therefore improve kinematic outcome and functional results, following reconstruction. Addressing laterally based injuries may also improve the durability of intraarticular ACLR. Improving the anterior cruciate ligament (ACL graft replication of the normal ACL attachment points on the femur and the tibia, using either double bundle or anatomical single bundle techniques, improves kinematics, which may benefit outcome and functionality, following reconstruction.

  8. Anterior Cruciate Ligament Injury, Reconstruction, and the Optimization of Outcome

    Science.gov (United States)

    Bliss, James Philip

    2017-01-01

    Anterior cruciate ligament reconstruction (ACLR) provides an established surgical intervention to control pathological tibiofemoral translational and rotational movement. ACLR is a safe and reproducible intervention, but there remains an underlying rate of failure to return to preinjury sporting activity levels. Postoperative pathological laxity and graft reinjury remain concerns. Previously, unrecognized meniscal lesions, disruption of the lateral capsule, and extracapsular structures offer potential avenues to treat and to therefore improve kinematic outcome and functional results, following reconstruction. Addressing laterally based injuries may also improve the durability of intraarticular ACLR. Improving the anterior cruciate ligament (ACL) graft replication of the normal ACL attachment points on the femur and the tibia, using either double bundle or anatomical single bundle techniques, improves kinematics, which may benefit outcome and functionality, following reconstruction. PMID:28966384

  9. anterior hyaloidal fibrovascular proliferation

    African Journals Online (AJOL)

    Okonkwo

    It most commonly occurs after phakic vitrectomy and scleral buckling for diabetic traction retinal detachment. It usually manifests with haemorrhage into the vitreous cavity or anterior hyaloid 3 to 12 weeks after vitrectomy and is the result of fibrovascular proliferation from the peripheral retina extending toward the equator of ...

  10. The Ultrawideband Leaky Lens Antenna

    NARCIS (Netherlands)

    Bruni, S.; Neto, A.; Marliani, F.

    2007-01-01

    A novel directive and nondispersive antenna is presented: the ultrawideband (UWB) leaky lens. It is based on the broad band Cherenkov radiation occurring at a slot printed between different infinite homogeneous dielectrics. The first part of the paper presents the antenna concept and the UWB design.

  11. ECTOPIC LENS EXTRACTION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Vladimir Pfeifer

    2002-12-01

    Full Text Available Background. Ectopia lentis continues to be a therapeutic challenge for ophthalmologists. It can occur as an isolated condition, after ocular trauma, in association with other ocular disorders, as part of a systemic mesodermal disease or a complication of general metabolic disorders. Minimal subluxation of the lens may cause no visual symptoms, but in more advanced cases serious optical disturbances arise. The most important is amblyopia. Surgical treatment options include iris manipulation, lens discission, aspiration, intracapsular or extracapsular extraction, and pars plana lensectomy. The choice of surgical technique remains controversial, in part because of the historically poor visual results and high rate of perioperative complications, including vitreous loss and retinal detachment.Methods. We describe a surgical technique based on the use of the Cionni endocapsular tension ring, dry irrigation aspiration of lens material, centration of the capsular bag and foldable intraocular lens implantation into the bag. With mentioned surgical technique 8 patients were operated; 4 boys and 4 girls, together 11 eyes.Results. The final BCVA after follow up period improved in 9 eyes and it remained the same as before operation in one eye. Statistical comparison of preoperative and postoperative visual acuities showed significant improvement. On the other hand there was no correlation between preoperative and postoperative visual acuity.Conclusions. This surgical procedure is an alternative approach in solving this challenging cases of ectopia lentis with good postoperative visual rehabilitation.

  12. Spinning pipe gas lens revisited

    CSIR Research Space (South Africa)

    Mafusire, C

    2008-01-01

    Full Text Available , there is little information on optical phase aberrations and no study to date on the propagation parameters of the laser beam, but has rather remained rooted in the domain of ray optics. Researchers revisit the spinning pipe gas lens in this paper with new...

  13. Carbachol as miotic agent in intra-ocular lens implant surgery

    Directory of Open Access Journals (Sweden)

    Agarwal Jitendra

    1988-01-01

    Full Text Available The intra cameral use of 0.025% carbachol as a miotic agent in anterior chamber intraocular lens im-plant surgery us reported in 15 cases. Carbachol produced prompt and effective moisis and was found to be harmless and non-irritating to the anterior chamber structures. A rebound dialatation of the pipit was noticed in the post operative period in 3 of our first 5 cases where only carbachol was used. For prolonged miosis instillation of a more powerful miotic like pilocarpine is recommended at the completion of surgery:

  14. Intraocular Lens Dislocation after Cataract Surgery in Tambolaka, Southwest Sumba, Indonesia: A Case Report

    OpenAIRE

    Ratna Sitompul

    2018-01-01

    Intraocular lens (IOL) dislocation is a rare complication of cataract extraction requiring prompt surgery. This case report aims to raise awareness of such cases and the importance of post-surgery follow-up. A 58-year-old female patient was found with anterior IOL dislocation a week after phacoemulsification surgery in her right eye. Visual acuity of the right eye was 1/60 with ciliary injection and IOL dislocation to the anterior chamber of the right eye. The patient underwent surgery of the...

  15. Results of phacoemulsification of cataract complicated by lens subluxation depending on the ring setting method

    Directory of Open Access Journals (Sweden)

    N. G. Zavgorodnjaja

    2015-02-01

    Full Text Available Actuality. Cataract extraction complicated by zonular weakness remains one of the urgent problems of eye microsurgery. Aim. To increase the efficiency of cataract surgery complicated by lens subluxation through comparative analysis of frequency and structure of intra- and postoperative complications, as well as the functional results of surgical treatment of patients depending on the ring setting method. Methods and results. 91 patients (93 eyes were examined, who were operated on complicated cataract, and were divided into 2 groups depending on the method of ring setting. Conclusion. It was established that the offered method of implant capsular ring gives the opportunity to reduce the length of patients’ treatment by 2,6 day, to decrease of 28,43% for complications, and also to avoid such heavy operating complications, as a vitreous prolapse, displacement of the eye lens fragments in a vitreous body, dug up capsule bag.

  16. Tube entrance lens focus control

    Science.gov (United States)

    Weisser, D. C.; Fifield, L. K.; Kitchen, T. F. G.; Tunningley, T. B.; Lobanov, N. R.; Muirhead, A. G.

    2013-02-01

    The entrance of the accelerator tube in a large electrostatic accelerator imposes a strong lens that dominates the beam optics. The magnification of the lens is large because of the low injection energy, the high voltage gradient of the acceleration tube and the long distance to the terminal. In the absence of the acceleration, the magnification would produce an unacceptably large beam spot at the terminal. The tyranny of the lens is especially irksome when the accelerator is required to operate at a lower terminal voltage than the one corresponding to the nominal gradient at high voltage. One way around the difficulty, used in NEC Pelletron accelerators, is to insert a series of nylon and steel rods that short together units of the acceleration structure at the terminal leaving the ones near the entrance close to the nominal gradient for optimum transmission. This operation takes time and risks the loss of insulating gas. Another alternative used in the 25URC at Oak Ridge National Laboratory, is to focus the beam at the tube entrance, substantially diluting the effect of the entrance lens. The beam then diverges and so requires an additional lens part way to the terminal. This solution is only partially effective and still necessitates use of shorting rods for low voltage operation. The fact that these elaborate strategies are used is evidence that the alternative of lowering the injection energy as the terminal voltage is lowered imposes enough problems that it is not used in practice. We have modeled a solution that controls the voltage gradient at the tube entrance using an external power supply. This not only maintains the focusing effect of the lens but provides the opportunity to tune the beam by adjusting the entrance lens. A 150 kV power supply outside the pressure vessel feeds a controllable voltage through a high voltage feed-through to the fifth electrode of the accelerator tube. Thus 150 kV on this electrode creates the nominal gradient of 30 kV per

  17. Indications for and results of a large series of intraocular lens exchanges.

    Science.gov (United States)

    Sinskey, R M; Amin, P; Stoppel, J O

    1993-01-01

    We conducted a retrospective review of 79 patients who had intraocular lens (IOL) explantation and exchange over a 12-year period. Seventy-nine eyes of 40 males and 39 females from 17 to 94 years of age were followed from three months to more than 12 years. Sixty-one percent (61%) were posterior chamber lenses and 39% were anterior chamber lenses replaced by 76% posterior chamber and 24% anterior chamber lenses. The indications for lens exchange were eccentric or displaced IOL (41.7%), endothelial decompensation (27.7%), incorrect IOL power (12.6%), and uveitis-glaucoma-hyphema syndrome (10.0%). Analysis of the clinical results revealed that 72% of the cases had postoperative visual acuity better than or equal to 20/30, and 8% had a loss of one or more lines of visual acuity. Among the complications occurring after IOL exchange were retinal detachment, glaucoma, corneal decompensation, and anisometropia.

  18. Evaluation of Artisan aphakic intraocular lens in cases of pediatric aphakia with insufficient capsular support.

    Science.gov (United States)

    Gawdat, Ghada I; Taher, Sameh G; Salama, Marwa M; Ali, Adel A

    2015-06-01

    To evaluate the visual outcomes and complications after Artisan iris-claw lens implantation in aphakic children with insufficient capsular support. In this prospective, interventional noncontrolled study, aphakic eyes of consecutive patients >2 years of age with insufficient capsular support who underwent Artisan intraocular lens (IOL) implantation between June 2011 and December 2012 were followed for 1 year. Patients with anterior chamber depth IOL were included, 18 eyes with subluxated lens and 7 following trauma. The mean preoperative logMAR best-corrected visual acuity for traumatic aphakic patients was 0.95 ± 0.36; for patients with subluxation, 0.7 ± 0.26. Values improved at 1 year to 0.38 ± 0.15 (P IOL implantation for pediatric aphakia achieved a good visual outcome. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  19. Isolation of Capsulate Bacteria from Acute Dentoalveolar Abscesses

    OpenAIRE

    Lewis, M. A. O.; Milligan, S. G.; MacFarlane, T. W.; Carmichael, F. A.

    2011-01-01

    The presence of a capsule was determined for 198 bacterial strains (57 facultative anaerobes, 141 strict anaerobes) isobdted from pus samples aspirated from 40 acute dentoalveolar abscesses. A total of 133 (67 per cent) of the isolates (42 facultative anaerobes, 91 strict anaerobes) were found to have a capsule. Possession ofa capsule may in part explain the apparent pathogenicity of the bacterial species encountered in acute dentoalveolar abscess.Keywords - Bacterial capsule; Acute dentoalve...

  20. Ultrasound capsule endoscopy: sounding out the future.

    Science.gov (United States)

    Cox, Benjamin F; Stewart, Fraser; Lay, Holly; Cummins, Gerard; Newton, Ian P; Desmulliez, Marc P Y; Steele, Robert J C; Näthke, Inke; Cochran, Sandy

    2017-05-01

    Video capsule endoscopy (VCE) has been of immense benefit in the diagnosis and management of gastrointestinal (GI) disorders since its introduction in 2001. However, it suffers from a number of well recognized deficiencies. Amongst these is the limited capability of white light imaging, which is restricted to analysis of the mucosal surface. Current capsule endoscopes are dependent on visual manifestation of disease and limited in regards to transmural imaging and detection of deeper pathology. Ultrasound capsule endoscopy (USCE) has the potential to overcome surface only imaging and provide transmural scans of the GI tract. The integration of high frequency microultrasound (µUS) into capsule endoscopy would allow high resolution transmural images and provide a means of both qualitative and quantitative assessment of the bowel wall. Quantitative ultrasound (QUS) can provide data in an objective and measurable manner, potentially reducing lengthy interpretation times by incorporation into an automated diagnostic process. The research described here is focused on the development of USCE and other complementary diagnostic and therapeutic modalities. Presently investigations have entered a preclinical phase with laboratory investigations running concurrently.

  1. Calcitonin effects on shoulder adhesive capsulitis.

    Science.gov (United States)

    Rouhani, Alireza; Mardani-Kivi, Mohsen; Bazavar, Mohammadreza; Barzgar, Mahmood; Tabrizi, Ali; Hashemi-Motlagh, Keyvan; Saheb-Ekhtiari, Khashayar

    2016-08-01

    Adhesive capsulitis (frozen shoulder) is a relatively prevalent disease of shoulder and affects soft tissue of glenohumeral joint. Signs include painful restricted motion and disability of the patient in daily activities. Calcitonin is a thyroid hormone, and its effectiveness has been demonstrated in painful conditions. The presents study aims to evaluate the effect of calcitonin in treating shoulder adhesive capsulitis. This double-blinded randomized clinical trial was conducted on 64 patients suffering from shoulder adhesive capsulitis. The intervention and control groups were given intranasal calcitonin and placebo for 6 weeks, respectively. For both groups, physiotherapy and non-steroidal anti-inflammatory drugs were administered correspondingly. The patients were evaluated pre- and post-treatment for shoulder pain and shoulder range of motion (ROM). Shoulder functional outcome (secondary outcome) was evaluated using Disability of Arm, Shoulder, and Hand, Shoulder Pain and Disability Index, and Health Assessment Questionnaire disability criteria. The mean age of patients in calcitonin and control group was 52.4 ± 4.6 and 53.2 ± 4.9, respectively. Demographic characteristics and pre-treatment scores were similar in both groups (all P > 0.05). In post-treatment follow-up, shoulder pain, ROM, and the patients' functional scores were significantly improved in both groups (P adhesive capsulitis with regard to the efficiency in alleviating pain and improving functional outcome. II.

  2. Diagnosis and management of adhesive capsulitis

    OpenAIRE

    Manske, Robert C.; Prohaska, Daniel

    2008-01-01

    Adhesive capsulitis is a musculoskeletal condition that has a disabling capability. This review discusses the diagnosis and both operative and nonoperative management of this shoulder condition that causes significant morbidity. Issues related to medications, rehabilitation, and post surgical considerations are discussed.

  3. Design of Endoscopic Capsule With Multiple Cameras.

    Science.gov (United States)

    Gu, Yingke; Xie, Xiang; Li, Guolin; Sun, Tianjia; Wang, Dan; Yin, Zheng; Zhang, Pengfei; Wang, Zhihua

    2015-08-01

    In order to reduce the miss rate of the wireless capsule endoscopy, in this paper, we propose a new system of the endoscopic capsule with multiple cameras. A master-slave architecture, including an efficient bus architecture and a four level clock management architecture, is applied for the Multiple Cameras Endoscopic Capsule (MCEC). For covering more area of the gastrointestinal tract wall with low power, multiple cameras with a smart image capture strategy, including movement sensitive control and camera selection, are used in the MCEC. To reduce the data transfer bandwidth and power consumption to prolong the MCEC's working life, a low complexity image compressor with PSNR 40.7 dB and compression rate 86% is implemented. A chipset is designed and implemented for the MCEC and a six cameras endoscopic capsule prototype is implemented by using the chipset. With the smart image capture strategy, the coverage rate of the MCEC prototype can achieve 98% and its power consumption is only about 7.1 mW.

  4. Capsule Endoscopy: New Technology, Old Complication ...

    African Journals Online (AJOL)

    Wireless capsule endoscopy is a new tool in the armamentarium of the gastroenterologist to evaluate the small bowel non-invasively. It allows improved diagnostic yield with low complication rates relative to traditional modalities. But this new technology has its own set of complications, some which can lead to significant ...

  5. Wireless capsule endoscopy: perspectives beyond gastrointestinal bleeding.

    Science.gov (United States)

    Redondo-Cerezo, Eduardo; Sánchez-Capilla, Antonio Damián; De La Torre-Rubio, Paloma; De Teresa, Javier

    2014-11-14

    Wireless capsule endoscopy (CE) is a technology developed for the endoscopic exploration of the small bowel. The first capsule model was approved by the Food and Drug Administration in 2001, and its first and essential indication was occult gastrointestinal (GI) bleeding. Over subsequent years, this technology has been refined to provide superior resolution, increased battery life, and capabilities to view different parts of the GI tract. Indeed, cases for which CE proved useful have increased significantly over the last few years, with new indications for the small bowel and technical improvements that have expanded its use to other parts of the GI tract, including the esophagus and colon. The main challenges in the development of CE are new devices with the ability to provide therapy, air inflation for a better vision of the small bowel, biopsy sampling systems attached to the capsule and the possibility to guide and move the capsule with an external motion control. In this article we review the current and new indications of CE, and the evolving technological changes shaping this technology, which has a promising potential in the coming future of gastroenterology.

  6. Hardware image assessment for wireless endoscopy capsules.

    Science.gov (United States)

    Khorsandi, M A; Karimi, N; Samavi, S; Hajabdollahi, M; Soroushmehr, S M R; Ward, K; Najarian, K

    2016-08-01

    Wireless capsule endoscopy is a new technology in the realm of telemedicine that has many advantages over the traditional endoscopy systems. Transmitted images should help diagnosis of diseases of the gastrointestinal tract. Two important technical challenges for the manufacturers of these capsules are power consumption and size of the circuitry. Also, the system must be fast enough for real-time processing of image or video data. To solve this problem, many hardware designs have been proposed for implementation of the image processing unit. In this paper we propose an architecture that could be used for the assessment of endoscopy images. The assessment allows avoidance of transmission of medically useless images. Hence, volume of data is reduced for more efficient transmission of images by the endoscopy capsule. This is done by color space conversion and moment calculation of images captured by the capsule. The inputs of the proposed architecture are RGB image frames and the outputs are images with converted colors and calculated image moments. Experimental results indicate that the proposed architecture has low complexity and is appropriate for a real-time application.

  7. Wireless Capsule Enteroscopy in Healthy Volunteers.

    Science.gov (United States)

    Tachecí, Ilja; Bradna, Petr; Douda, Tomáš; Baštecká, Drahomíra; Kopáčová, Marcela; Rejchrt, Stanislav; Lutonský, Martin; Soukup, Tomáš; Bureš, Jan

    The aim of our prospective study was to define endoscopy appearance of the small bowel in healthy volunteers. Forty-two healthy volunteers underwent wireless capsule endoscopy, clinical investigation, laboratory tests, and completed a health-status questionnaire. All subjects were available for a 36-month clinical follow-up. Eleven subjects (26%) had fully normal endoscopy findings. Remaining 31 persons (74%), being asymptomatic, with normal laboratory results, had some minor findings at wireless capsule endoscopy. Most of those heterogeneous findings were detected in the small intestine (27/31; 87%), like erosions and/or multiple red spots, diminutive polyps and tiny vascular lesions. During a 36-month clinical follow-up, all these 42 healthy volunteers remained asymptomatic, with fully normal laboratory control. Significant part of healthy subjects had abnormal findings at wireless capsule endoscopy. These findings had no clinical relevance, as all these persons remained fully asymptomatic during a 36-month follow-up. Such an endoscopic appearance would be previously evaluated as "pathological". This is a principal report alerting that all findings of any control group of wireless capsule endoscopic studies must be evaluated with caution.

  8. Wireless Capsule Enteroscopy in Healthy Volunteers

    Directory of Open Access Journals (Sweden)

    Ilja Tachecí

    2016-09-01

    Full Text Available Introduction: The aim of our prospective study was to define endoscopy appearance of the small bowel in healthy volunteers. Method: Forty-two healthy volunteers underwent wireless capsule endoscopy, clinical investigation, laboratory tests, and completed a health-status questionnaire. All subjects were available for a 36-month clinical follow-up. Results: Eleven subjects (26% had fully normal endoscopy findings. Remaining 31 persons (74%, being asymptomatic, with normal laboratory results, had some minor findings at wireless capsule endoscopy. Most of those heterogeneous findings were detected in the small intestine (27/31; 87%, like erosions and/or multiple red spots, diminutive polyps and tiny vascular lesions. During a 36-month clinical follow-up, all these 42 healthy volunteers remained asymptomatic, with fully normal laboratory control. Conclusions: Significant part of healthy subjects had abnormal findings at wireless capsule endoscopy. These findings had no clinical relevance, as all these persons remained fully asymptomatic during a 36-month follow-up. Such an endoscopic appearance would be previously evaluated as “pathological”. This is a principal report alerting that all findings of any control group of wireless capsule endoscopic studies must be evaluated with caution.

  9. Can we reduce capsule endoscopy reading times?

    NARCIS (Netherlands)

    Westerhof, Jessie; Koornstra, Jan J.; Weersma, Rinse K.

    Background: Analyzing small-bowel capsule endoscopy (CE) images is time Consuming. Objective: To determine the effect of reducing the number Of images on reacting time and interpretation of CE procedures. Design: Two techniques aimed at reducing the number of images to he viewed were Studied. The

  10. Biosorption of lead by Gram-ve capsulated and non-capsulated ...

    African Journals Online (AJOL)

    Citrobacter freundii ) or capsulated (Klebsiella pneumoniae) was characterised. Lead biosorption was found to be influenced by the pH of the solution, initial metal concentration, and amount of the dried powdered cells and contact time. Thus, the ...

  11. Is there an application for wireless capsule endoscopy in horses?

    Science.gov (United States)

    Montgomery, Julia B; Bracamonte, Jose L; Alam, Mohammad Wajih; Khan, Alimul H; Mohammed, Shahed K; Wahid, Khan A

    2017-12-01

    This pilot study assessed wireless capsule endoscopy in horses. Image transmission was achieved with good image quality. Time to exit the stomach was variable and identified as one limitation, together with gaps in image transmission, capsule tumbling, and inability to accurately locate the capsule. Findings demonstrate usefulness and current limitations.

  12. 21 CFR 872.3110 - Dental amalgam capsule.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  13. Modern lens antennas for communications engineering

    CERN Document Server

    Thornton, John

    2012-01-01

    The aim of this book is to present the modern design principles and analysis of lens antennas. It gives graduates and RF/Microwave professionals the design insights in order to make full use of lens antennas.  Why do we want to write a book in lens antennas? Because this topic has not been thoroughly publicized, its importance is underestimated. As antennas play a key role in communication systems, recent development in wireless communications would indeed benefit from the characteristics of lens antennas: low profile, and low cost etc.  The major advantages of lens antennas are na

  14. Refractive lens exchange and piggyback intraocular lens implantation in nanophthalmos: Visual and structural outcomes.

    Science.gov (United States)

    Mohebbi, Masoomeh; Fallah-Tafti, Mohammad-Reza; Fadakar, Kaveh; Katoozpour, Ramon; Mohammadi, Seyed-Farzad; Fallah-Tafti, Zahra; Khorami, Azita

    2017-09-01

    To evaluate the best piggyback intraocular lens (IOL) implantation method and the outcomes in nanophthalmos eyes and to define the postoperative structural changes. Farabi Eye Hospital, Tehran, Iran. Prospective case series. Candidates for refractive surgery who were nanophthalmic were recruited. Patients had refractive lens exchange followed by implantation of both IOLs in the bag or 1 IOL in the bag and 1 IOL in the sulcus. The baseline and follow-up visual acuity, refractive status, and structural Scheimpflug imaging were evaluated. Ultrasound biomicroscopy (UBM) was performed 6 months postoperatively. The study comprised 9 nanophthalmic patients (18 eyes) with a mean preoperative uncorrected distance visual acuity (UDVA) of 1.53 logarithm of the minimum angle of resolution (logMAR) ± 0.3 (SD), mean corrected distance visual acuity (CDVA) of 0.34 ± 0.2 logMAR, and mean spherical equivalent (SE) of +13.55 ± 4.0 diopters (D). The mean postoperative UDVA improved from baseline. There was no significant difference in the mean UDVA and CDVA between the 2 IOL groups. Postoperatively, both groups had a significant improvement in SE, a significant rise in anterior chamber depth and angle, and similar UBM measurements. Piggyback IOL implantation was an effective refractive procedure in nanophthalmic eyes. Both implantation methods resulted in similar outcomes; however, the small number of patients in each group made it less likely that possible differences would be found. The increase in angle values might help prevent the development of closed-angle glaucoma. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Anterior cruciate ligament repair - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100230.htm Anterior cruciate ligament repair - Series—Normal anatomy To use the sharing ... to slide 5 out of 5 Overview The anterior cruciate ligament (ACL) is a ligament in the center of ...

  16. Multidisciplinary management of anterior diastemata

    DEFF Research Database (Denmark)

    Furuse, Adilson Yoshio; Herkrath, Fernando José; Franco, Eduardo Jacomino

    2007-01-01

    Anterior diastemata may compromise the harmony of a patient's smile. Consideration of etiologic factors, previous gingival conditioning, and individual treatment planning are essential in the proper management of anterior diastemata. An integrated orthodontic-restorative approach may enhance...

  17. Outcomes of Lensectomy in Hereditary Lens Subluxation

    Directory of Open Access Journals (Sweden)

    Mohammad-Hossein Dehghan

    2008-12-01

    Full Text Available

    PURPOSE: To evaluate the results of pars plana lensectomy in patients with hereditary lens subluxation. METHOD: Hospital records of patients with hereditary lens subluxation who had undergone pars plana lensectomy at Labbafinejad Medical Center, Tehran-Iran from 1996 to 2003 were reviewed. Patients with more than 6 months of follow up were included. Underlying disorders, best corrected visual acuity (BCVA before and after surgery, intraocular pressure (IOP, postoperative refraction and complications were evaluated. RESULTS: Overall, records of 87 eyes of 49 patients including 27 male and 22 female subjects were reviewed. Mean follow up duration was 20±18 months. Underlying disorders leading to lens subluxation included Marfan syndrome (79.5%, Weill-Marchesani syndrome (8.2%, simple ectopia lentis (8.2%, and homocystinuria (4.1%. The most common indication for surgery was non-correctable refractive error (92.1%. Mean BCVA was 1.13 LogMAR (20/250 preoperatively, which improved to 0.26 LogMAR (20/30-20/40 postoperatively (P < 0.001. BCVA better than 20/40 was achieved in 82.8% of cases after surgery. Angle-supported anterior chamber intraocular lens (ACIOL was implanted in

  18. Contact lens surface by electron beam

    International Nuclear Information System (INIS)

    Shin, Jung Hyuck; Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin

    2011-01-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility

  19. Lens decenter and tilt measurement by interferogram

    Science.gov (United States)

    Hung, Min-Wei; Wu, Wen-Hong; Huang, Kuo-Cheng

    2009-11-01

    For the recent years, the vigorous development of the electro-optic industry, particularly the digital camera and the cellular phone camera, has placed a larger and larger demand for the optical devices. Among the optical lens, the aspherical optical lens plays the key component because the aspherical lens may provide better imaging quality then the spherical lens does. For the manufacturing reason, the aspherical lens is prone to a decenter or tilt issue with respect to the optical axes of its two surfaces. To measure decenter and tile error specifically would help to obviate the deficient lens, but most of the present measuring method can't provide this function. This paper proposed a new method to specifically measure the decenter and tile of lens by observing the interferogram of each surface. And the corresponding measuring instrument, which contains interferometer and motion stages, was introduced as well.

  20. A Class I UV-blocking (senofilcon A) soft contact lens prevents UVA-induced yellow fluorescence and NADH loss in the rabbit lens nucleus in vivo.

    Science.gov (United States)

    Giblin, Frank J; Lin, Li-Ren; Simpanya, Mukoma F; Leverenz, Victor R; Fick, Catherine E

    2012-09-01

    It is known that fluorescence, much of it caused by UVA light excitation, increases in the aging human lens, resulting in loss of sharp vision. This study used an in vivo animal model to investigate UVA-excited fluorescence in the rabbit lens, which contains a high level of the UVA chromophore NADH, existing both free and bound to λ-crystallin. Also, the ability of a Class I (senofilcon A) soft contact lens to protect against UVA-induced effects on the rabbit lens was tested. Rabbit eyes were irradiated with UVA light in vivo (100 mW/cm(2) on the cornea) for 1 h using monochromatic 365 nm light. Irradiation was conducted in the presence of either a senofilcon A contact lens, a minimally UV-absorbing lotrafilcon A contact lens, or no contact lens at all. Eyes irradiated without a contact lens showed blue 365 nm-excited fluorescence initially, but this changed to intense yellow fluorescence after 1 h. Isolated, previously irradiated lenses exhibited yellow fluorescence originating from the lens nucleus when viewed under 365 nm light, but showed normal blue fluorescence arising from the cortex. Previously irradiated lenses also exhibited a faint yellow color when observed under visible light. The senofilcon A contact lens protected completely against the UVA-induced effects on fluorescence and lens yellowing, whereas the lotrafilcon A lens showed no protection. The UVA-exposure also produced a 53% loss of total NADH (free plus bound) in the lens nucleus, with only a 13% drop in the anterior cortex. NADH loss in the nucleus was completely prevented with use of a senofilcon A contact lens, but no significant protection was observed with a lotrafilcon A lens. Overall, the senofilcon A lens provided an average of 67% protection against UVA-induced loss of four pyridine nucleotides in four different regions of the lens. HPLC analysis with fluorescence detection indicated a nearly six-fold increase in 365 nm-excited yellow fluorescence arising from lens nuclear

  1. Maintenance of the anterior chamber during penetrating keratoplasty.

    Science.gov (United States)

    Kramer, S G; Stewart, H L

    1976-01-01

    A description of the author's (S.G.K.) technique for penetrating keratoplasty is provided. The salient features include corneal removal, storage, and corneal graft cutting procedures of Kaufman and his co-workers. In addition, a specially designed suturing contact lens is described which allows maintenance of the anterior chamber during penetrating keratoplasty. It is suggested that trauma to the all-important cornea endothelium can be minimized by application of this technique, because it significantly reduces the likelihood of endothelial trauma induced by mechanical contact of the endothelium with intraocular recipient structures during suturing.

  2. Utility of MR arthrography in the diagnosis of adhesive capsulitis

    Energy Technology Data Exchange (ETDEWEB)

    Manton, G.L.; Schweitzer, M.E.; Weishaupt, D.; Karasick, D. [Dept. of Radiology, Thomas Jefferson Univ. Hospital, Philadelphia, PA (United States)

    2001-06-01

    Objective. Arthrographically, adhesive capsulitis is characterized by decreased joint volume; histologically, the capsule and synovium are thickened. We therefore compared using MR arthrography the joint volumes and capsule/synovial thickness of patients with and without adhesive capsulitis in order to assess the utility of MR arthrography in diagnosing adhesive capsulitis.Design and patients. The 1.5 T MR arthrography images of 28 subjects with (n=9) and without (n=19) adhesive capsulitis were compared. Adhe- sive capsulitis was diagnosed when there was an injected glenohumeral joint volume of less than 10 ml. Two masked observers working in consensus assessed the images for the relative amount of fluid in the biceps tendon sheath and axillary recess, corrugation at the margin of the capsule, capsule/synovial thickness, abnormalities of the rotator interval capsule, and for the presence of a cuff tear.Results. There was a trend towards differences in capsular and synovial thickness (P>0.07) between the subjects with and without adhesive capsulitis; however, the controls had thicker synovium/capsules. Surprisingly, the amount of fluid in the axillary recess and biceps tendon sheath was not significantly different between the groups (P>0.25). There were more tears of the rotator cuff in controls than in patients with adhesive capsulitis (6, 3 vs 1, 1: complete, partial). Also, both corrugation (7 vs 0) and interval abnormalities (7 vs 0) were more common in the controls.Conclusion. There appear to be no useful MR arthrographic signs of adhesive capsulitis. Capsular/synovial thickness, static fluid volume, and the presence of corrugation are inconclusive as MR arthrographic signs for distinguishing shoulders with adhesive capsulitis from those without. (orig.)

  3. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  4. Ossifying fibroma involving the paranasal sinuses, orbit, and anterior cranial fossa: case report.

    Science.gov (United States)

    Nakagawa, K; Takasato, Y; Ito, Y; Yamada, K

    1995-06-01

    We report a case of ossifying fibroma involving the paranasal sinuses, orbit, and anterior cranial fossa. Ossifying fibroma is a benign fibro-osseous tumor, rarely involving the anterior cranial base. The patient was admitted because of exophthalmos and diplopia. The lesion was totally removed surgically. Grossly, it had a thin osseous capsule. The microscopic examination showed mainly fibrous tissues and lamellar bone trabeculae rimmed by osteoblasts and myxomatous areas in some parts. The histopathological aspect of this entity is discussed with reference to the differential diagnosis from monostotic fibrous dysplasia.

  5. A wireless capsule endoscopy steering mechanism using magnetic field platform.

    Science.gov (United States)

    Alsunaydih, Fahad N; Redoute, Jean-Michel; Yuce, Mehmet R

    2017-07-01

    In this paper, a new steering mechanism for wireless capsule devices is presented. The proposed system consists of a platform generating a magnetic field to direct and control the motion of a capsule. The platform contains an upper and a lower set of electromagnets. A permanent magnet is implanted inside the capsule to initiate the movement, which is set by the magnetic field delivered by the electromagnets. The total magnetic field at the capsule's location is the sum of the contributions of each electromagnet. An experimental setup has been designed for testing and comparing between the performance of the capsule mobility in practice and simulations.

  6. Symptomatic Patency Capsule Retention in Suspected Crohn's Disease

    DEFF Research Database (Denmark)

    Rasmussen, Bjørn; Nathan, Torben; Jensen, Michael Dam

    2016-01-01

    The main limitation of capsule endoscopy is the risk of capsule retention. In patients with suspected Crohn's disease, however, this complication is rare, and if a small bowel stenosis is not reliably excluded, small bowel patency can be confirmed with the Pillcam patency capsule. We present two...... patients examined for suspected Crohn's disease who experienced significant symptoms from a retained patency capsule. Both patients had Crohn's disease located in the terminal ileum. In one patient, the patency capsule caused abdominal pain and vomiting and was visualized at magnetic resonance enterography...

  7. Fornical and nonfornical projections from the rat hippocampal formation to the anterior thalamic nuclei

    Science.gov (United States)

    Dillingham, Christopher M.; Erichsen, Jonathan T.; O'Mara, Shane M.; Aggleton, John P.

    2015-01-01

    ABSTRACT The hippocampal formation and anterior thalamic nuclei form part of an interconnected network thought to support memory. A central pathway in this mnemonic network comprises the direct projections from the hippocampal formation to the anterior thalamic nuclei, projections that, in the primate brain, originate in the subicular cortices to reach the anterior thalamic nuclei by way of the fornix. In the rat brain, additional pathways involving the internal capsule have been described, linking the dorsal subiculum to the anteromedial thalamic nucleus, as well as the postsubiculum to the anterodorsal thalamic nucleus. Confirming such pathways is essential in order to appreciate how information is transferred from the hippocampal formation to the anterior thalamus and how it may be disrupted by fornix pathology. Accordingly, in the present study, pathway tracers were injected into the anterior thalamic nuclei and the dorsal subiculum of rats with fornix lesions. Contrary to previous descriptions, projections from the subiculum to the anteromedial thalamic nucleus overwhelmingly relied on the fornix. Dorsal subiculum projections to the majority of the anteroventral nucleus also predominantly relied on the fornix, although postsubicular inputs to the lateral dorsal part of the anteroventral nucleus, as well as to the anterodorsal and laterodorsal thalamic nuclei, largely involved a nonfornical pathway, via the internal capsule. © 2015 The Authors Hippocampus Published by Wiley Periodicals, Inc. PMID:25616174

  8. Wireless capsule endoscopy years after Michelassi stricturoplasty for Crohn's disease.

    Science.gov (United States)

    Sciaudone, G; Pellino, G; Guadagni, I; Pezzullo, A; Selvaggi, F

    2010-01-01

    The use of wireless capsule endoscopy in Crohn's disease has been a matter of debate. We report the case of a 27-year-old woman operated for Crohn's disease with a Michelassi stricturoplasty presenting with anaemia. We tested the patient with a patency capsule before undertaking a wireless capsule endoscopy. Although the absorbable capsule was successfully expelled, the wireless capsule was retained next to the distal edge of the Michelassi stricturoplasty, where it revealed an otherwise undetected stenotic recurrence. We successfully treated the recurrence with a Heineke-Mikulicz stricturoplasty on the stenotic outlet of the previous Michelassi, extracting the capsule. We found our treatment effective. We believe that capsule endoscopy can be performed in patients operated on for Crohn's disease, although further studies are needed to clarify its role in patients with long-stricturoplasties and to establish which examination could be the most effective in selecting patients.

  9. Looking beyond the perfect lens

    International Nuclear Information System (INIS)

    Wee, W H; Pendry, J B

    2010-01-01

    The holy grail of imaging is the ability to see through anything. From the conservation of energy, we can easily see that to see through a lossy material would require lenses with gain. The aim of this paper therefore is to propose a simple scheme by which we can construct a general perfect lens, with gain-one that can restore both the phases and amplitudes of near and far fields.

  10. CONTACT LENS RELATED CORNEAL ULCER

    Directory of Open Access Journals (Sweden)

    AGARWAL P

    2010-01-01

    Full Text Available A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are:overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. The presenting symptoms of contact lens related corneal ulcers include eye discomfort, foreign body sensation and lacrimation. More serious symptoms are redness (especially circum-corneal injection, severe pain, photophobia, eye discharge and blurring of vision. The diagnosis is established by a thorough slit lamp microscopic examination with fluorescein staining and corneal scraping for Gram stain and culture of the infective organism. Delay in diagnosing and treatment can cause permanent blindness, therefore an early referral to ophthalmologist and commencing of antimicrobial therapy can prevent visual loss.

  11. Microscopic analysis of an opacified OFT CRYL® hydrophilic acrylic intraocular lens

    Directory of Open Access Journals (Sweden)

    Bruna Vieira Ventura

    Full Text Available ABSTRACT A 51-year-old patient underwent posterior vitrectomy with perfluoropropane gas injection, phacoemulsification, and implantation of an Oft Cryl® hydrophilic acrylic intraocular lens (IOL because of traumatic retinal detachment and cataract in the right eye. On the first postoperative day, gas was filling the anterior chamber because of patient's non-compliance in terms of head positioning, and was reabsorbed within one week. Eight months later, the patient returned complaining of a significant decrease in vision. IOL opacification was noticed by slit-lamp examination. The lens was explanted to undergo gross and light microscopic analysis. The lens was also stained with the alizarin red method for calcium identification. Light microscopic analysis confirmed the presence of granular deposits, densely distributed in an overall circular pattern in the central part of the lens optic. The granules stained positive for calcium. This is the first case of the opacification of this type of hydrophilic lens. Surgeons should be aware of this potential postoperative complication, and the use of hydrophilic IOLs should be avoided in procedures involving intracameral gas because of the risk of IOL opacification.

  12. A case of Alagille syndrome complicated by intraocular lens subluxation and rhegmatogenous retinal detachment

    Directory of Open Access Journals (Sweden)

    Fukumoto M

    2013-07-01

    Full Text Available Masanori Fukumoto, Tsunehiko Ikeda, Tetsuya Sugiyama, Mari Ueki, Takaki Sato, Eisuke Ishizaki Department of Ophthalmology, Osaka Medical College, Takatsuki City, Japan Abstract: This case report describes a case of Alagille syndrome with developing intraocular lens subluxation and rhegmatogenous retinal detachment 4 years after cataract surgery. A 15-year-old female patient with Alagille syndrome-associated cataracts in both eyes underwent phacoemulsification aspiration and intraocular lens implantation. Four years postoperative, intraocular lens subluxation developed in her left eye. For treatment, extraction of the dislocated intraocular lens, anterior vitrectomy, and intraocular lens fixation was performed. Three weeks later, the patient developed rhegmatogenous retinal detachment, which was well-treated by pars plana vitrectomy. Cataract surgery needs to be performed carefully in patients with Alagille syndrome due to the weakness of the zonule of Zinn. Careful postoperative observation is necessary for patients with Alagille syndrome who have undergone intraocular surgery in order to facilitate early detection of a possible rhegmatogenous retinal detachment. Keywords: Alagille syndrome, cataract, retina, surgery

  13. Biological response in various compartments of the rat lens after in vivo exposure to UVR-B analyzed by HR-MAS 1H NMR spectroscopy.

    Science.gov (United States)

    Tessem, May-Britt; Bathen, Tone F; Löfgren, Stefan; Saether, Oddbjørn; Mody, Vino; Meyer, Linda; Dong, Xiuqin; Söderberg, Per G; Midelfart, Anna

    2006-12-01

    The purpose of the present study was to investigate metabolic changes in different compartments of the rat lens (anterior, nuclear, posterior, and equatorial) after exposure to an acute double threshold dose of ultraviolet-B radiation (UVR-B) by using high-resolution magic angle spinning (HR-MAS) (1)H nuclear magnetic resonance (NMR) spectroscopy and pattern recognition (PR) METHODS: methods. One eye in each of 28 6-week-old female albino Sprague-Dawley rats was exposed to in vivo 7.5 kJ/m2 UVR-B for 15 minutes. The contralateral eye was left unexposed. One week after irradiation, all rats were killed, and both lenses were isolated. Each lens was cored by a trephine, and the cylinder was sliced into three portions (anterior, nuclear, and posterior). The lens material that remained after the coring process was analyzed as the equatorial region. Analysis of lens metabolism was performed by HR-MAS 1H NMR spectroscopy (14.1 T; Avance DRX600; Bruker BioSpin GmbH, Rheinstetten, Germany), and the metabolic profiles were statistically analyzed by the PR method of principal component analysis (PCA). Metabolic differences were detected among the compartments in the lens, both in samples from the contralateral nonexposed lenses and in samples from lenses exposed to in vivo UVR-B. In the rat lens, exposure to UVR-B caused changes in GSH, phosphocholine, myo-inositol, succinate, formate, and adenosine triphosphate (ATP)/adenosine diphosphate (ADP) and in levels of the amino acids phenylalanine, taurine, hypo-taurine, tyrosine, alanine, valine, isoleucine, and glutamate, that varied among lens compartments. HR-MAS 1H NMR spectroscopy, combined with PR methods (PCA), is effective for analysis of separate parts of the intact rat lens. To understand the biochemistry of the lens, it is important to divide the lens into sections, representing functionally and anatomically distinct compartments.

  14. Perawatan Ortodontik Gigitan Terbuka Anterior

    Directory of Open Access Journals (Sweden)

    Yuniar Zen

    2014-06-01

    Full Text Available Perawatan gigitan terbuka anterior telah lama dianggap sebagai tantangan bagi ortodontis. Prevalensi gigitan terbuka anterior antara 3,5% hingga 11% terdapat pada berbagai usia dan kelompok etnis, serta ada sekitar 17% pasien ortodonti memiliki gigitan terbuka. Stabilitas hasil perawatan gigitan terbuka anterior sangat sulit, karena adanya kombinasi diskrepansi anteroposterior dengan gigitan terbuka skeletal sehingga dibutuhkan tingkat keterampilan diagnosis dan klinis yang tinggi. Etiologi gigitan terbuka anterior sangat kompleks karena dapat melibatkan skeletal, dental, dan faktor-faktor habitual. Eliminasi faktor etiologi merupakan hal yang penting dalam perawatan gigitan terbuka anterior. Berbagai cara perawatan untuk koreksi gigitan terbuka anterior diantaranya bedah ortognatik dan perawatan ortodontik kamuflase, seperti high-pull headgear, chincup, bite blocks, alatfungsional, pencabutan gigi, multi-loop edgewise archwires dan mini implan. Stabilitas hasil perawatan adalah kriteria yang paling penting dalam menentukan cara perawatan gigitan terbuka anterior. Orthodontic Treatment of Anterior Open Bite. An anterior open bite therapy has long been considered a challenge to orthodontist. The prevalence of anterior openbite range from 3,5 % to 11% among various age and ethnic groups and it has been shown that approximately 17% of orthodontic patients have open bite. Stability of treatment result of anterior open bite with well-maintained results is difficult, because the combination of anteroposteriorly discrepancy with skeletal open bite requires the highest degree of diagnostic and clinical skill. The etiology is complex, potentially involving skeletal, dental and habitual factors. The importance of an anterior open bite therapy is to eliminate the cause of the open bite. Various treatment modalities for the correction of an anterior open bite have been proposed, orthognatic surgery and orthodontic camouflage treatment such as high

  15. Contact lens induced Pseudomonas keratitis following descemet stripping automated endothelial keratoplasty.

    Science.gov (United States)

    Dhiman, Rebika; Singh, Archita; Tandon, Radhika; Vanathi, M

    2015-10-01

    To report a case of bandage contact lens induced infectious keratitis caused by Pseudomonas aeruginosa following DSAEK. A 56-year-old female who underwent DSAEK at our institute for pseudophakic bullous keratopathy, developed contact lens induced keratitis in the fifth post operative week. Best corrected visual acuity (BCVA) reduced to perception of light in the left eye. Slit lamp examination revealed an epithelial ulcer measuring 4.7mm×6mm with surrounding infiltrates in the anterior stroma with hypopyon. The interface was clear. The corneoscleral rim culture of the donor tissue showed no growth on bacterial and fungal culture ruling out the possibility of donor-to-host transmission of infection. Microbiological evaluation identified the causative agent to be Pseudomonas aeruginosa. Based on culture and sensitivity report patient was started on hourly instillation of topical polymyxin B 20,000IU and fortified ceftazidime 5%. A response to treatment was noted and there was a complete resolution of keratitis with residual scarring. There have been case reports suggesting a host to donor transmission of infection which manifests during the postoperative period. To the best of our knowledge there are no reports of bandage contact lens associated Pseudomonas keratitis in a case that has undergone DSAEK. The prolonged use of bandage contact lens, lens contamination, stagnation of tear film behind the lens, compromised ocular surface and post operative use of topical steroids can contribute to infectious keratitis in DSAEK cases. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  16. UV-B–Induced DNA Damage and Repair in the Mouse Lens

    Science.gov (United States)

    Mesa, Rosana; Bassnett, Steven

    2013-01-01

    Purpose. Epidemiologic studies have linked UV-B exposure to development of cortical cataracts, but the underlying molecular mechanism(s) is unresolved. Here, we used a mouse model to examine the nature and distribution of DNA photolesions produced by ocular UV-B irradiation. Methods. Anesthetized mice, eye globes, or isolated lenses were exposed to UV-B. Antibodies specific for 6-4 photoproducts (6-4 PPs) or cyclobutane pyrimidine dimers (CPDs) were used to visualize DNA adducts. Results. Illumination of intact globes with UV-B–induced 6-4 PP and CPD formation in cells of the cornea, anterior iris, and central lens epithelium. Photolesions were not detected in retina or lens cells situated in the shadow of the iris. Photolesions in lens epithelial cells were produced with radiant exposures significantly below the minimal erythemal dose. Lens epithelial cells rapidly repaired 6-4 PPs, but CPD levels did not markedly diminish, even over extended postirradiation recovery periods in vitro or in vivo. The repair of 6-4 PPs did not depend on the proliferative activity of the epithelial cells, since the repair rate in the mitotically-active germinative zone (GZ) was indistinguishable from that of quiescent cells in the central epithelium. Conclusions. Even relatively modest exposures to UV-B produced 6-4 PP and CPD photolesions in lens epithelial cells. Cyclobutane pyrimidine dimer lesions were particularly prevalent and were repaired slowly if at all. Studies on sun-exposed skin have established a causal connection between photolesions and so-called UV-signature mutations. If similar mechanisms apply in the lens, it suggests that somatic mutations in lens epithelial cells may contribute to the development of cortical cataracts. PMID:24022010

  17. UV-B-induced DNA damage and repair in the mouse lens.

    Science.gov (United States)

    Mesa, Rosana; Bassnett, Steven

    2013-10-17

    Epidemiologic studies have linked UV-B exposure to development of cortical cataracts, but the underlying molecular mechanism(s) is unresolved. Here, we used a mouse model to examine the nature and distribution of DNA photolesions produced by ocular UV-B irradiation. Anesthetized mice, eye globes, or isolated lenses were exposed to UV-B. Antibodies specific for 6-4 photoproducts (6-4 PPs) or cyclobutane pyrimidine dimers (CPDs) were used to visualize DNA adducts. Illumination of intact globes with UV-B-induced 6-4 PP and CPD formation in cells of the cornea, anterior iris, and central lens epithelium. Photolesions were not detected in retina or lens cells situated in the shadow of the iris. Photolesions in lens epithelial cells were produced with radiant exposures significantly below the minimal erythemal dose. Lens epithelial cells rapidly repaired 6-4 PPs, but CPD levels did not markedly diminish, even over extended postirradiation recovery periods in vitro or in vivo. The repair of 6-4 PPs did not depend on the proliferative activity of the epithelial cells, since the repair rate in the mitotically-active germinative zone (GZ) was indistinguishable from that of quiescent cells in the central epithelium. Even relatively modest exposures to UV-B produced 6-4 PP and CPD photolesions in lens epithelial cells. Cyclobutane pyrimidine dimer lesions were particularly prevalent and were repaired slowly if at all. Studies on sun-exposed skin have established a causal connection between photolesions and so-called UV-signature mutations. If similar mechanisms apply in the lens, it suggests that somatic mutations in lens epithelial cells may contribute to the development of cortical cataracts.

  18. Adhesive capsulitis of the hip: a review.

    Science.gov (United States)

    Looney, Colin G; Raynor, Brett; Lowe, Rebecca

    2013-12-01

    Adhesive capsulitis of the hip (ACH) is a rare clinical entity. Similar to adhesive capsulitis of the shoulder, ACH is characterized by a painful decrease in active and passive range of motion as synovial inflammation in the acute stages of the disease progresses to capsular fibrosis in the chronic stages. Once other diagnoses have been ruled out, management of ACH is tailored to reduce inflammation in the acute stages with NSAIDs, intra-articular steroid injections, and targeted physical therapy while biomechanical dysfunction in the spine, hip, sacroiliac joint, or lower limb joints is addressed. In chronic stages of the disease, intervention should focus on decreasing the progression of fibrotic changes and regaining range of motion through aggressive physical therapy. Interventions described for chronic ACH include manipulation under anesthesia; pressure dilatation; and open or arthroscopic synovectomy, lysis of adhesions, and capsular release. Surgical intervention should be considered only after failure of a minimum 3-month course of nonsurgical treatment.

  19. Polymeric multilayer capsules in drug delivery.

    Science.gov (United States)

    De Cock, Liesbeth J; De Koker, Stefaan; De Geest, Bruno G; Grooten, Johan; Vervaet, Chris; Remon, Jean Paul; Sukhorukov, Gleb B; Antipina, Maria N

    2010-09-17

    Recent advances in medicine and biotechnology have prompted the need to develop nanoengineered delivery systems that can encapsulate a wide variety of novel therapeutics such as proteins, chemotherapeutics, and nucleic acids. Moreover, these delivery systems should be "intelligent", such that they can deliver their payload at a well-defined time, place, or after a specific stimulus. Polymeric multilayer capsules, made by layer-by-layer (LbL) coating of a sacrificial template followed by dissolution of the template, allow the design of microcapsules in aqueous conditions by using simple building blocks and assembly procedures, and provide a previously unmet control over the functionality of the microcapsules. Polymeric multilayer capsules have recently received increased interest from the life science community, and many interesting systems have appeared in the literature with biodegradable components and biospecific functionalities. In this Review we give an overview of the recent breakthroughs in their application for drug delivery.

  20. Air bubble and Viscoelastic agents in production of posterior capsular opacity and pigment deposition over the intraocular lens

    Directory of Open Access Journals (Sweden)

    H Attarzadeh

    2006-05-01

    Full Text Available Background: In cataract surgery, viscoelastic agents form anterior chamber, complicating to posterior capsular opacity and pigment deposition over intraocular lens after lens implantation. We compared the rate of these complications for air bubble and viscoelastic agents. Methods: Patients with senile cataract and candidate for routine cataract extraction were studied. They were randomly divided into group A (n=62 and group B (n=66. During operation and at the time of intraocular lens implantation, anterior chamber was formed by air bubble (in group A and with viscoelastic agents (in group B. All patients were followed for 3 to 6 months. Results: The rate of posterior capsular opacity and pigment deposition over the intraocular lens were significantly higher in group B (40.9% vs. 21% than group A (30.3% vs. 9.7%, respectively. Conclusion: Air bubble is a good substitution for viscoelastic agents in the formation of anterior chamber during cataract, either for decreasing complications or expensive materials. Keywords: Posterior capsular opacity, cataract extraction, viscoelastic agent, air bubble

  1. Technology of swallowable capsule for medical applications

    OpenAIRE

    Intzes, I; Meng, H; Cosmas, J

    2014-01-01

    Medical technology has undergone major breakthroughs in recent years, especially in the area of the examination tools for diagnostic purposes. This paper reviews the swallowable capsule technology in the examination of the gastrointestinal system for various diseases. The wireless camera pill has created a more advanced method than many traditional examination methods for the diagnosis of gastrointestinal diseases such as gastroscopy by the use of an endoscope. After years of great innovation...

  2. Adhesive capsulitis. Is it possible in childhood?

    OpenAIRE

    Modesto, C. (C.); Crespo, E. (Eduardo); Villas, C. (Carlos); Aquerreta, D. (Dámaso)

    1995-01-01

    Adhesive capsulitis affecting shoulders has been extensively studied by orthopedic surgeons, but few reports have been published on this condition when it affects other joints (hips, ankles). To our knowledge no pediatric cases have been reported. As its treatment requires prolonged physiotherapy and sometimes manipulation, a correct diagnosis is essential. We would like to emphasize the importance of having this condition in mind when one is regarding a differential diagnosis, also in children.

  3. Automatic blood detection in capsule endoscopy video

    Czech Academy of Sciences Publication Activity Database

    Novozámský, Adam; Flusser, Jan; Tachecí, I.; Sulík, L.; Bureš, J.; Krejcar, O.

    2016-01-01

    Roč. 21, č. 12 (2016), s. 1-8, č. článku 126007. ISSN 1083-3668 R&D Projects: GA ČR GA15-16928S Institutional support: RVO:67985556 Keywords : Automatic blood detection * capsule endoscopy video Subject RIV: JD - Computer Applications, Robotics Impact factor: 2.530, year: 2016 http://library.utia.cas.cz/separaty/2016/ZOI/flusser-0466936.pdf

  4. Constraints on oxygen fugacity within metal capsules

    Science.gov (United States)

    Faul, Ulrich H.; Cline, Christopher J., II; Berry, Andrew; Jackson, Ian; Garapić, Gordana

    2017-12-01

    Experiments were conducted with olivine encapsulated or wrapped in five different metals (Pt, Ni, Ni_{70}Fe_{30} , Fe, and Re) to determine the oxygen fugacity in the interior of large capsules used for deformation and seismic property experiments. Temperature (1200°C ), pressure (300 MPa), and duration (24 h) were chosen to represent the most common conditions in these experiments. The oxygen fugacity was determined by analysing the Fe content of initially pure Pt particles that were mixed with the olivine powder prior to the experiments. Oxygen fugacities in the more oxidizing metal containers are substantially below their respective metal-oxide buffers, with the fO_2 of sol-gel olivine in Ni about 2.5 orders of magnitude below Ni-NiO. Analysis of olivine and metal blebs reveals three different length-, and hence diffusive time scales: (1) Fe loss to the capsule over ˜ 100 μm, (2) fO_2 gradients at the sample-capsule interface up to 2 mm into the sample, and (3) constant interior fO_2 values with an ordering corresponding to the capsule material. The inferred diffusive processes are: Fe diffusion in olivine with a diffusivity ˜ 10^{-14} m^2/s , diffusion possibly of oxygen along grain boundaries with a diffusivity ˜ 10^{-12} m^2/s , and diffusion possibly involving pre-existing defects with a diffusivity ˜ 10^{-10} m^2/s . The latter, fast adjustment to changing fO_2 may consist of a rearrangement of pre-existing defects, representing a metastable equilibrium, analogous to decoration of pre-existing defects by hydrogen. Full adjustment to the external fO_2 requires atomic diffusion.

  5. Hemispherical Capsule Implosions for Fast Ignition*

    Science.gov (United States)

    Hanson, D. L.; Vesey, R. A.; Sinars, D. B.; Adams, R. G.; Cuneo, M. E.; Porter, J. L.; Slutz, S. A.; Johnston, R. R.; Wenger, D. F.; Schroen, D. G.

    2003-10-01

    The fast ignitor approach to ICF ignition separates the fuel assembly and fast heating processes. After compressing the fuel with the main driver, the fuel is ignited using a focused electron or ion beam generated by a fast, ultra-high power laser pulse. This significantly relaxes the drive symmetry, energy, and shock timing requirements compared to hot spot ignition. A hemispherical capsule target is a fast ignitor geometry well-adapted to symmetric fuel compression by a single-ended z-pinch radiation drive. The hemispherical capsule implodes radially, constrained at its equator by a flat high-density surface (a special case of the spherical capsule "cone-focus" geometry). This glide plane is mounted on a hollow pedestal that provides a plasma-free, short-pulse laser path to the compressed fuel core region. In experiments on the Z accelerator at Sandia, we are studying implosions of 2.0-mm-diameter, 60-micron-thick hemispherical capsules in cylindrical secondary hohlraums heated to 90-100 eV from one end by a 120 TW wire-array z-pinch. Analysis of ZBL 6.7 keV point-projection backlighter images of pole-hot implosions in a tall secondary and 6.18 keV monochromatic crystal backlighter images of more symmetric implosions in a short secondary will be presented. We will also discuss progress on the development of a cryogenic liquid fuel target for this fast ignitor compression geometry. * Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under Contract DE-AC04-94AL85000.

  6. Anterior knee pain

    Energy Technology Data Exchange (ETDEWEB)

    LLopis, Eva [Hospital de la Ribera, Alzira, Valencia (Spain) and Carretera de Corbera km 1, 46600 Alzira Valencia (Spain)]. E-mail: ellopis@hospital-ribera.com; Padron, Mario [Clinica Cemtro, Ventisquero de la Condesa no. 42, 28035 Madrid (Spain)]. E-mail: mario.padron@clinicacemtro.com

    2007-04-15

    Anterior knee pain is a common complain in all ages athletes. It may be caused by a large variety of injuries. There is a continuum of diagnoses and most of the disorders are closely related. Repeated minor trauma and overuse play an important role for the development of lesions in Hoffa's pad, extensor mechanism, lateral and medial restrain structures or cartilage surface, however usually an increase or change of activity is referred. Although the direct relation of cartilage lesions, especially chondral, and pain is a subject of debate these lesions may be responsible of early osteoarthrosis and can determine athlete's prognosis. The anatomy and biomechanics of patellofemoral joint is complex and symptoms are often unspecific. Transient patellar dislocation has MR distinct features that provide evidence of prior dislocation and rules our complication. However, anterior knee pain more often is related to overuse and repeated minor trauma. Patella and quadriceps tendon have been also implicated in anterior knee pain, as well as lateral or medial restraint structures and Hoffa's pad. US and MR are excellent tools for the diagnosis of superficial tendons, the advantage of MR is that permits to rule out other sources of intraarticular derangements. Due to the complex anatomy and biomechanic of patellofemoral joint maltracking is not fully understood; plain films and CT allow the study of malalignment, new CT and MR kinematic studies have promising results but further studies are needed. Our purpose here is to describe how imaging techniques can be helpful in precisely defining the origin of the patient's complaint and thus improve understanding and management of these injuries.

  7. Factors associated with strabismus after cataract extraction and primary intraocular lens implantation in congenital cataracts

    Directory of Open Access Journals (Sweden)

    Soo Jung Lee

    2014-06-01

    Full Text Available AIM: To evaluate factors associated with the development of strabismus after cataract extraction and primary intraocular lens implantation.METHODS: The medical records of 122 patients, aged 1.5mo to 9y, who had undergone cataract extraction with primary intraocular lens implantation between January 1993 and August 2011 were reviewed. Fourteen patients (17 eyes with strabismus before cataract surgery were excluded. Patients were divided into those with congenital bilateral cataracts (64 patients, 128 eyes and those with unilateral cataracts (44 patients, 44 eyes. The associations between the development of strabismus and age at cataract surgery, pre- and post-cataract extraction corrected distance visual acuity (CDVA, interocular CDVA difference, nystagmus, surgical method, and secondary cataract were evaluated.RESULTS: Factors significantly associated with the development of strabismus included age at cataract surgery (≤1y, preoperative mean CDVA ≤20/100, presence of nystagmus in the bilateral cataract group and postoperative interocular CDVA difference >20/70 in the unilateral group. Postoperative CDVA ≤20/100 and preservation of posterior capsule, and presence of secondary cataract were significant factors in both groups.CONCLUSION: Children with congenital cataracts should be monitored carefully after cataract surgery for the development of strabismus, especially when they underwent surgery at age ≤1y, and they have nystagmus, large postoperative interocular CDVA difference, poor preoperative and postoperative CDVA, preservation of the posterior capsule, or secondary cataract.

  8. Hot cell examination on the surveillance capsule and HANARO capsule in IMEF

    International Nuclear Information System (INIS)

    Choo, Yong Sun; Oh, Wan Ho; Yoo, Byung Ok; Jung, Yang Hong; Ahn, Sang Bok; Baik, Seung Je; Song, Wung Sup; Hong, Kwon Pyo

    2000-01-01

    For the maintenance of integrity and safety of pressurizer of commercial power plant until its life span, it is required by US NRC 10CFR50 APP. G and H and ASTM E185-94 to periodically monitor irradiation embrittlement by neutron irradiation. In order to accomplished the requirement reactor operator has been carrying out the test by extracting the monitoring capsule embeded in reactor during the period of planned preventive maintenance. In relation to this irradiation samples are being used for prediction of reactor vessel life span and reactor vessel's adjusted reference temperature by irradiation of neutron flux enough to reach to end of life span. And also irradiation capsules with and without instrumentation are used for R and D on nuclear materials. Each capsule contains high radioactivity, therefore, post irradiation examination has to be handled by all means in the hot cell. The facility available for this purpose is Irradiated material examination facility (IMEF) to handle such works as capsule receiving, capsule cut and dismantling, sample classification, various examination, and finally development and improvement of examination equipment and instrumentation. (Hong, J. S.)

  9. Evaluating anterior knee pain.

    Science.gov (United States)

    Hong, Engene; Kraft, Michael C

    2014-07-01

    Musculoskeletal complaints account for about 20% to 30% of all primary care office visits; of these visits, discomfort in the knee, shoulder, and back are the most prevalent musculoskeletal symptoms. Having pain or dysfunction in the front part of the knee is a common presentation and reason for a patient to see a health care provider. There are a number of pathophysiological etiologies to anterior knee pain. This article describes some of the common and less common causes, and includes sections on diagnosis and treatment for each condition as well as key points. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. The anterior cingulate cortex

    Directory of Open Access Journals (Sweden)

    Pavlović D.M.

    2009-01-01

    Full Text Available The anterior cingulate cortex (ACC has a role in attention, analysis of sensory information, error recognition, problem solving, detection of novelty, behavior, emotions, social relations, cognitive control, and regulation of visceral functions. This area is active whenever the individual feels some emotions, solves a problem, or analyzes the pros and cons of an action (if it is a right decision. Analogous areas are also found in higher mammals, especially whales, and they contain spindle neurons that enable complex social interactions. Disturbance of ACC activity is found in dementias, schizophrenia, depression, the obsessive-compulsive syndrome, and other neuropsychiatric diseases.

  11. Precise measurement of scleral radius using anterior eye profilometry.

    Science.gov (United States)

    Jesus, Danilo A; Kedzia, Renata; Iskander, D Robert

    2017-02-01

    To develop a new and precise methodology to measure the scleral radius based on anterior eye surface. Eye Surface Profiler (ESP, Eaglet-Eye, Netherlands) was used to acquire the anterior eye surface of 23 emmetropic subjects aged 28.1±6.6years (mean±standard deviation) ranging from 20 to 45. Scleral radius was obtained based on the approximation of the topographical scleral data to a sphere using least squares fitting and considering the axial length as a reference point. To better understand the role of scleral radius in ocular biometry, measurements of corneal radius, central corneal thickness, anterior chamber depth and white-to-white corneal diameter were acquired with IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany). The estimated scleral radius (11.2±0.3mm) was shown to be highly precise with a coefficient of variation of 0.4%. A statistically significant correlation between axial length and scleral radius (R 2 =0.957, pscleral radius. Lastly, no correlation was observed comparing scleral radius to the central corneal thickness (R 2 =0.047, p=0.161). Three-dimensional topography of anterior eye acquired with Eye Surface Profiler together with a given estimate of the axial length, can be used to calculate the scleral radius with high precision. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  12. Effects of food on a gastrically degraded drug: azithromycin fast-dissolving gelatin capsules and HPMC capsules.

    Science.gov (United States)

    Curatolo, William; Liu, Ping; Johnson, Barbara A; Hausberger, Angela; Quan, Ernest; Vendola, Thomas; Vatsaraj, Neha; Foulds, George; Vincent, John; Chandra, Richa

    2011-07-01

    Commercial azithromycin gelatin capsules (Zithromax®) are known to be bioequivalent to commercial azithromycin tablets (Zithromax®) when dosed in the fasted state. These capsules exhibit a reduced bioavailability when dosed in the fed state, while tablets do not. This gelatin capsule negative food effect was previously proposed to be due to slow and/or delayed capsule disintegration in the fed stomach, resulting in extended exposure of the drug to gastric acid, leading to degradation to des-cladinose-azithromycin (DCA). Azithromycin gelatin capsules were formulated with "superdisintegrants" to provide fast-dissolving capsules, and HPMC capsule shells were substituted for gelatin capsule shells, in an effort to eliminate the food effect. Healthy volunteers were dosed with these dosage forms under fasted and fed conditions; pharmacokinetics were evaluated. DCA pharmacokinetics were also evaluated for the HPMC capsule subjects. In vitro disintegration of azithromycin HPMC capsules in media containing food was evaluated and compared with commercial tablets and commercial gelatin capsules. When the two fast-dissolving capsule formulations were dosed to fed subjects, the azithromycin AUC was 38.9% and 52.1% lower than after fasted-state dosing. When HPMC capsules were dosed to fed subjects, the azithromycin AUC was 65.5% lower than after fasted-state dosing. For HPMC capsules, the absolute fasting-state to fed-state decrease in azithromycin AUC (on a molar basis) was similar to the increase in DCA AUC. In vitro capsule disintegration studies revealed extended disintegration times for commercial azithromycin gelatin capsules and HPMC capsules in media containing the liquid foods milk and Ensure®. Interaction of azithromycin gelatin and HPMC capsules with food results in slowed disintegration in vitro and decreased bioavailability in vivo. Concurrent measurement of serum azithromycin and the acid-degradation product DCA demonstrates that the loss of azithromycin

  13. Refraction and eye anterior segment parameters in schizophrenic patients

    Directory of Open Access Journals (Sweden)

    Tongabay Cumurcu

    2015-06-01

    Full Text Available ABSTRACT Purpose: To evaluate the difference in terms of refractive errors and anterior segment parameters between schizophrenic patients and healthy volunteers. Methods: This study compared 70 patients (48 men who were diagnosed with schizophrenia with a control group of 60 (35 men who were similar in terms of age, gender, education, and socioeconomic level. Anterior segment examination was performed using a Scheimflug system. Axial length and lens thickness (LT were measured using optic biometry. The following tests were administered to the psychiatric patient group: Brief Psychiatric Rating Scale (BPRS, Scale for the Assessment of Negative Symptoms (SANS, and Scale for the Assessment of Positive Symptoms (SAPS. Results: Mild myopia was detected in both the schizophrenic and control groups, with no statistically significant difference (p>0.005. Corneal volume (CV, anterior chamber volume (ACV, anterior chamber depth (ACD, and central corneal thickness (CCT values were lower in the schizophrenic group, and there was a statistically significant between-group difference (p=0.026, p=0.014, p=0.048, and p=0.005, respectively. LT was greater in schizophrenics, and the difference was found to be statistically significant (p=0.006. A statistically significant negative correlation was found between SAPS and cylinder values (p=0.008. The axial eye length, cylinder value, pupil diameter, mean keratometric value, and anterior chamber angle revealed no statistically significant difference between the groups (p>0.05. Conclusion: No statistically significant difference was detected in terms of refraction disorders between schizophrenics and the healthy control group, while some differences in anterior chamber parameters were present. These results demonstrate that schizophrenics may exhibit clinical and structural differences in the eye.

  14. Accessory optical device for the Heidelberg retina angiograph ( HRA classic to perform angiography of the vitreous cavity and the anterior eye segment

    Directory of Open Access Journals (Sweden)

    Mennel Stefan

    2007-01-01

    Full Text Available The Heidelberg retina angiograph ( HRA classic enables fluorescein angiography (FA and indocyanine green angiography (ICG-A of the retina and choroid. The goal of this study was to design an accessory device to adapt the HRA classic for application on structures anterior to the retina. The optical device consisted of a cylindrical two-piece plastic frame holding a magnifying lens commonly used with the indirect ophthalmoscope. A 60-diopters lens was inserted in this frame to enable the angiography of the anterior segment. A less strong lens of 30 diopters was used for the visualization of pathologic findings in the vitreous cavity. We designed an easy-to-use and low-cost device to adapt the HRA classic for angiography of the fundus, vitreous cavity and anterior segment in the same session and without delay. FA and ICG-A images of two patients with rubeosis iridis and of one patient with choroidal melanoma are described.

  15. Influence of anterior segment biometric parameters on the anterior chamber angle width in eyes with angle closure.

    Science.gov (United States)

    Matsuki, Takaaki; Hirose, Fumitaka; Ito, Shin-Ichiro; Hata, Masayuki; Hirami, Yasuhiko; Kurimoto, Yasuo

    2015-02-01

    To predict angle narrowing in eyes with angle closure in a Japanese population using anterior segment optical coherence tomography (AS-OCT) quantitative parameters. AS-OCT was used to examine 118 eyes of 118 patients with angle closure and 40 eyes of 40 patients with open angle under dark conditions. After measuring the angle opening distance 500 (AOD500), anterior chamber depth, iris thickness (IT), iris convexity (IC), pupil diameter, anterior chamber width, and crystalline lens rise, multivariate regression analyses were performed for the AOD500 in each group. With the exception of IT, significant differences were observed between the AS-OCT parameters for the angle closure and open-angle groups. Anterior chamber depth, IT, and IC were the explanatory variables associated with AOD500 for each group (P≤0.001). A significant negative association was found between IT and IC only in the angle-closure group (Pchamber depth was a major mechanism of angle narrowing, and that both IT and IC had a strong impact on angle narrowing. Moreover, the negative association found between IT and IC in only the angle closure group indicated the existence of the stretch force placed on the iris by relative pupillary block.

  16. Research on one manual zoom liquid lens

    Science.gov (United States)

    Zhao, Cunhua; Shi, Yongpeng; Li, Wenjiao; Li, Congcong

    2011-11-01

    In liquid zoom lens, the accurate fixed-focus location needs the accurate calculation of focal length. That is to say, the accurate calculation of surface curvature must be obtained. Therefore, the research of their relation in liquid zoom lens becomes extremely important which has a directly theoretical instruction for the design of liquid zoom lenses. In our paper, the relation is studied. A manual liquid lens is reported which has upper and nether components with specificaton Φ12×5mm. The zoom lens is obtained by the upper component circumvolving down into the nether components.

  17. Numerical analyses of planer plasmonic focusing lens

    Science.gov (United States)

    Chou, Yen-Yu; Lee, Yeeu-Chang

    2018-03-01

    The use of polystyrene (PS) sphere lithography has been widely applied in the fabrication of micron and nano structures, due to their low cost and ease of fabrication in large scale applications. This study evaluated the feasibility of plasmonic lens base on metal thin films with nanohole structures fabricated by using PS sphere lithography through three-dimensional (3D) finite difference time domain (FDTD) method. We calculated the intensity profile of lens with various wavelength of incident light, lens size, cutting positions, diameters of nanohole, and periods of nanohole to investigate the geometric parameters influence on the focusing properties of the plasmonic lens.

  18. TGF-β1 serum concentrations and receptor expressions in the lens capsular of dogs with diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Stephan Neumann

    2017-01-01

    Full Text Available Tissue fibrosis as complication of Diabetes mellitus is known in humans. Because TGF-β1induces fibrosis and is elevated in humans suffering from Diabetes mellitus we measured this growth factor in serum of dogs with Diabetes mellitus and compared it with healthy dogs and those with fibrotic diseases. Further we measured the expression of TGF-β1receptor on lens capsule to investigate possible association between Diabetes mellitus and cataract associated alterations. TGF-β1 was measured in serum of 12 dogs with Diabetes mellitus, 20 healthy controls and 12 dogs with fibrotic diseases. Dogs with Diabetes mellitus and fibrotic diseases have significantly increased TGF-β1 serum concentrations compared to healthy controls. Some dogs with Diabetes mellitus showed increased expression of TGF-β1 receptor in lens capsule. Based on our observations we can conclude that TGF-β1 elevation in dogs with Diabetes mellitus may induces complications of the disease and may participates on lens alteration.

  19. TGF-β1 serum concentrations and receptor expressions in the lens capsular of dogs with diabetes mellitus.

    Science.gov (United States)

    Neumann, Stephan; Linek, Jens; Loesenbeck, Gerhard; Schüttler, Julia; Gaedke, Sonja

    2017-01-01

    Tissue fibrosis as complication of diabetes mellitus is known in humans. Because TGF-β1induces fibrosis and is elevated in humans suffering from diabetes mellitus we measured this growth factor in serum of dogs with diabetes mellitus and compared it with healthy dogs and those with fibrotic diseases. Further we measured the expression of TGF-β1receptor on lens capsule to investigate possible association between diabetes mellitus and cataract associated alterations. TGF-β1 was measured in serum of 12 dogs with diabetes mellitus, 20 healthy controls and 12 dogs with fibrotic diseases. Dogs with diabetes mellitus and fibrotic diseases have significantly increased TGF-β1 serum concentrations compared to healthy controls. Some dogs with diabetes mellitus showed increased expression of TGF-β1 receptor in lens capsule. Based on our observations we can conclude that TGF-β1 elevation in dogs with diabetes mellitus may induces complications of the disease and may participates on lens alteration.

  20. [Lens exchange for subluxation of posterior chamber lenses implanted in the capsular bag or in the ciliary sulcus].

    Science.gov (United States)

    Stürmer, J

    2013-04-01

    There are an increasing number of patients with decreased vision due to dislocated posterior chamber lenses, with pseudoexfoliation being the main risk factor. Various techniques for refixation of the subluxated posterior chamber IOL have been described. Experience with our technique of IOL-explantation, anterior vitrectomy and implantation of an Artisan anterior chamber lens are presented. In a retrospective study design all lens exchanges with implantation of an Artisan anterior chamber lens performed between 2003 and 2012 are analyzed. The study included 65 eyes of 61 patients (age 79.6 ± 9.2 years: 43-98). The majority of eyes (46/65; 70.8%) had Sundown Syndrome (late in-the-bag intraocular lens dislocation), in 19 eyes the posterior chamber lens was implanted primary or secondary into the ciliary sulcus. In the 46 eyes with Sundown Syndrome cataract surgery with implantation of a posterior chamber lens in the capsular bag was performed 7.4 ± 3.7 (1-22) years before subluxation within the bag. Pseudoexfoliation was the main risk factor in 42/46 (91.2%) of these eyes. A capsular tension ring (CTR) was implanted during cataract surgery in 34/46 (73.9%) eyes. The 34 IOLs with a CTR luxated significantly earlier (p IOLs without a CTR (6.6 ± 3.6 years; median 5.8 vs. 9.4 ± 3.1 years; median 9.2). The average visual gain was 0.2 logMAR in the group of luxated capsular bag lenses and 0.12 logMAR in the group of luxated sulcus lenses. Postoperative IOP decompensation was seen in 17/65 (26.2%) eyes (requiring IOP-lowering surgery in 8 eyes), 7 eyes developed corneal decompensation, 5 eyes had central retinal vein occlusion and one eye developed postoperative endophthalmitis. Lens exchange with implantation of an Artisan anterior chamber lens has become a routine procedure to improve vision in patients with subluxated IOLs. Postoperative IOP decompensation and vascular problems are the major complications. Georg Thieme Verlag KG Stuttgart · New York.

  1. SOME COMPUCATIONS OF LENS EXTRACTION

    African Journals Online (AJOL)

    1971-04-10

    Apr 10, 1971 ... must not procrastinate. A new passage for the aqueous from posterior to anterior chamber must be made, and the sooner the better. There are two possible approaches: 1. Iridotomy or iridectomy: one may make a new hole in the iris-by simple transfixion iridotomy, or more pre- ferably by formal basal ...

  2. Lens Crystallin Modifications and Cataract in Transgenic Mice Overexpressing Acylpeptide Hydrolase*

    Science.gov (United States)

    Santhoshkumar, Puttur; Xie, Leike; Raju, Murugesan; Reneker, Lixing; Sharma, K. Krishna

    2014-01-01

    The accumulation of crystallin fragments in vivo and their subsequent interaction with crystallins are responsible, in part, for protein aggregation in cataracts. Transgenic mice overexpressing acylpeptide hydrolase (APH) specifically in the lens were prepared to test the role of protease in the generation and accumulation of peptides. Cataract development was seen at various postnatal days in the majority of mice expressing active APH (wt-APH). Cataract onset and severity of the cataracts correlated with the APH protein levels. Lens opacity occurred when APH protein levels were >2.6% of the total lens protein and the specific activity, assayed using Ac-Ala-p-nitroanilide substrate, was >1 unit. Transgenic mice carrying inactive APH (mt-APH) did not develop cataract. Cataract development also correlated with N-terminal cleavage of the APH to generate a 57-kDa protein, along with an increased accumulation of low molecular weight (LMW) peptides, similar to those found in aging human and cataract lenses. Nontransgenic mouse lens proteins incubated with purified wt-APH in vitro resulted in a >20% increase in LMW peptides. Crystallin modifications and cleavage were quite dramatic in transgenic mouse lenses with mature cataract. Affected lenses showed capsule rupture at the posterior pole, with expulsion of the lens nucleus and degenerating fiber cells. Our study suggests that the cleaved APH fragment might exert catalytic activity against crystallins, resulting in the accumulation of distinct LMW peptides that promote protein aggregation in lenses expressing wt-APH. The APH transgenic model we developed will enable in vivo testing of the roles of crystallin fragments in protein aggregation. PMID:24554718

  3. Exchange of tears under a contact lens is driven by distortions of the contact lens.

    Science.gov (United States)

    Maki, Kara L; Ross, David S

    2014-12-01

    We studied the flow of the post-lens tear film under a soft contact lens to understand how the design parameters of contact lenses can affect ocular health. When a soft contact lens is inserted, the blinking eyelid causes the lens to stretch in order to conform to the shape of the eye. The deformed contact lens acts to assume its un-deformed shape and thus generates a suction pressure in the post-lens tear film. In consequence, the post-lens tear fluid moves; it responds to the suction pressure. The suction pressure may draw in fresh fluid from the edge of the lens, or it may eject fluid there, as the lens reassumes its un-deformed shape. In this article, we develop a mathematical model of the flow of the post-lens tear fluid in response to the mechanical suction pressure of a deformed contact lens. We predict the amount of exchange of fluid exchange under a contact lens and we explore the influence of the eye's shape on the rate of exchange of fluid. © The Author 2014. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  4. Motion of an elastic capsule in a square microfluidic channel.

    Science.gov (United States)

    Kuriakose, S; Dimitrakopoulos, P

    2011-07-01

    In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e., small, moderate, and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross section in the upstream portion of large capsules is nonaxisymmetric (i.e., square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a(-2) for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux-U ~ h ~ a(-2

  5. Effect of hemodialysis on intraocular lens power calculation.

    Science.gov (United States)

    Çalışkan, Sinan; Çelikay, Osman; Biçer, Tolga; Aylı, Mehmet Deniz; Gürdal, Canan

    2016-01-01

    To evaluate changes in ocular biometric parameters after hemodialysis (HD) in patients with end-stage renal disease (ESRD). Forty eyes of 40 patients undergoing HD were included in this cross-sectional study. Keratometry (K) readings, white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber depth (ACD), pupil diameter, lens thickness (LT), axial length (AL), and intraocular lens (IOL) power calculation were measured with Lenstar LS 900 (Haag Streit AG, Koeniz, Switzerland) before and after hemodialysis. Intraocular pressure (IOP) was measured with a non-contact tonometer (Tonopachy NT-530P, Nidek Co., LTD, Tokyo, Japan). Main outcomes were changes in biometric parameters after HD. Reliability of the measurements (intraclass correlation coefficients (ICCs)) and the effect size (Cohen's d) were also calculated. Mean difference in AL before and after HD was -0.041 ± 0.022 mm with ICCs > 0.90 (p  0.90 (p = 0.041 and Cohen's d = 0.20). Hemodialysis had no significant effect on K readings, WTW distance, CCT, ACD, LT, or IOP. Axial length and pupil diameter increase after HD with small effect size, while HD does not significantly affect IOL power calculations.

  6. [Anterior guidance in complete dentures].

    Science.gov (United States)

    Dubreuil, J; Trevelo, A

    1990-01-01

    Although the anterior guidance in complete dentures is not really a guide, the arrangement of the anterior maxillary and mandibular prosthetic teeth, defines a propulsive line called the virtual anterior guidance, a part from the cinematic criterias. The influence of this guide on cuspal movement is superior, in all mandibular points, to the influence of the condylar pathway. If this line is not respected, the practitioner may have to do excessive grindings during occlusal adjustments.

  7. Multidisciplinary management of anterior diastemata

    DEFF Research Database (Denmark)

    Furuse, Adilson Yoshio; Herkrath, Fernando José; Franco, Eduardo Jacomino

    2007-01-01

    Anterior diastemata may compromise the harmony of a patient's smile. Consideration of etiologic factors, previous gingival conditioning, and individual treatment planning are essential in the proper management of anterior diastemata. An integrated orthodontic-restorative approach may enhance...... the aesthetic results when orthodontic therapy itself is not feasible. This article presents integrated orthodonticrestorative solutions of anterior diastemata, associated with the conditioning of the gingival tissue with composite resin, and discusses the most relevant aspects related to their etiology...

  8. Ocular Toxicity after High-Dose Cefuroxime Injection into the Anterior Chamber

    Directory of Open Access Journals (Sweden)

    Harun Çakmak

    2016-08-01

    Full Text Available Cephalosporins are beta-lactam antibiotics and, like penicillin derivatives, they show bacteriostatic effect by disrupting bacterial cell wall synthesis. Cefuroxime is a second generation cephalosporin and the use of intracameral cefuroxime after cataract surgery has been widely used in the endophthalmitis prophylaxis. A 78-year-old male patient was operated for cataracts in both eyes about 8 years ago. Ocular trauma has occurred in the left eye nine months ago. Vitrectomy surgery combined with intraocular lens extraction was performed and the patient was left aphakic. Secondary intraocular lens implantation was performed. In this paper, we present postoperative ocular findings in a patient who was given cefuroxime into the anterior chamber 2.5 times higher than the recommended dose (25 mg/ml after secondary intraocular lens implantation.

  9. Irradiation tests of materials using HANARO instrumented capsules in 2003

    International Nuclear Information System (INIS)

    Joo, K. M.; Joe, M. S.; Oh, J. M.; Shin, Y. T.; Kang, Y. H.; Lim, I. C.; Hwang, S. R.

    2003-01-01

    The HANARO irradiation capsule system has been actively utilized for the various irradiation tests requested by users of research institutes, universities, and industries. In 2003, two instrumented capsules were designed, fabricated, and successfully irradiated at HANARO and another is under fabrication. For the evaluation of the irradiation properties of the RPV(Reactor Pressure Vessel) materials and for the development of improved evaluation technology, 02M-02K instrumented capsule was designed, fabricated, and successfully irradiated at HANARO. 02M-05U instrumented capsule was designed, fabricated, and successfully irradiated as a part of 2002 project for active utilization of HANARO. Reactor core materials were also irradiated using 02M-05U capsule. Another instrumented capsule is under design and fabrication as a part of 2003 project for active utilization of HANARO and for the development of precise temperature controlling technology

  10. Wireless communication link for capsule endoscope at 600 MHz.

    Science.gov (United States)

    Khaleghi, A; Balasingham, I

    2015-01-01

    Simulation of a wireless communication link for a capsule endoscopy is presented for monitoring of small intestine in humans. The realized communication link includes the transmitting capsule antenna, the outside body receiving antenna and the model of the human body. The capsule antenna is designed for operating at the frequency band of 600 MHz with an impedance bandwidth of 10 MHz and omnidirectional radiation pattern. The quality of the communication link is improved by using directive antenna outside body inside matching layer for electromagnetic wave tuning to the body. The outside body antenna has circular polarization that guaranteeing the communication link for different orientations of the capsule inside intestine. It is shown that the path loss for the capsule in 60 mm from the abdomen surface varies between 37-47 dB in relation to the antenna orientation. This link can establish high data rate wireless communications for capsule endoscopy.

  11. Capsule development and utilization for material irradiation tests

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N. [and others

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules.

  12. Bioengineered anterior cruciate ligament

    Science.gov (United States)

    Altman, Gregory (Inventor); Kaplan, David (Inventor); Vunjak-Novakovic, Gordana (Inventor); Martin, Ivan (Inventor)

    2001-01-01

    The present invention provides a method for producing an anterior cruciate ligament ex vivo. The method comprises seeding pluripotent stem cells in a three dimensional matrix, anchoring the seeded matrix by attachment to two anchors, and culturing the cells within the matrix under conditions appropriate for cell growth and regeneration, while subjecting the matrix to one or more mechanical forces via movement of one or both of the attached anchors. Bone marrow stromal cells are preferably used as the pluripotent cells in the method. Suitable matrix materials are materials to which cells can adhere, such as a gel made from collagen type I. Suitable anchor materials are materials to which the matrix can attach, such as Goinopra coral and also demineralized bone. Optimally, the mechanical forces to which the matrix is subjected mimic mechanical stimuli experienced by an anterior cruciate ligament in vivo. This is accomplished by delivering the appropriate combination of tension, compression, torsion, and shear, to the matrix. The bioengineered ligament which is produced by this method is characterized by a cellular orientation and/or matrix crimp pattern in the direction of the applied mechanical forces, and also by the production of collagen type I, collagen type III, and fibronectin proteins along the axis of mechanical load produced by the mechanical forces. Optimally, the ligament produced has fiber bundles which are arranged into a helical organization. The method for producing an anterior cruciate ligament can be adapted to produce a wide range of tissue types ex vivo by adapting the anchor size and attachment sites to reflect the size of the specific type of tissue to be produced, and also adapting the specific combination of forces applied, to mimic the mechanical stimuli experienced in vivo by the specific type of tissue to be produced. The methods of the present invention can be further modified to incorporate other stimuli experienced in vivo by the

  13. Anterior versus posterior pin placement of pelvic C-clamp in relationship to anatomical structures: a cadaver study.

    Science.gov (United States)

    Reynolds, Jason H; Attum, Basem; Acland, Robert J; Giannoudis, Peter; Roberts, Craig S

    2008-08-01

    The objective of this study was to compare anterior and posterior pin placement of the pelvic C-clamp with specific reference to the proximity of the sciatic nerve, sciatic notch, hip joint capsule, and superior gluteal neurovascular bundle. The pelvic C-clamp (Synthes, Paoli, PA) was applied to eight extracted pelvic specimens and five full cadavers (26 hips in total). Anterior and posterior pin placements were measured in relationship to the described anatomical structures. In 100% of the hips the distance from the posterior pin to the hip joint capsule was in 21 (80.8%), 23 (88.5%), and 20 (76.9%) of the hips, the anterior pin distances were greater than the posterior pin distances to the sciatic nerve, sciatic notch, and superior gluteal neurovascular bundle, respectively. Anterior pin placement is further from all anatomical structures studies with the exception of the hip joint capsule. The posterior pin was closer to the sciatic nerve, sciatic notch, and superior gluteal neurovascular bundle in all cases. Clinical decision-making for C-clamp placement should be individualised on a case-by-case basis.

  14. Changes in biomechanical properties of glenohumeral joint capsules with adhesive capsulitis by repeated capsule-preserving hydraulic distensions with saline solution and corticosteroid.

    Science.gov (United States)

    Koh, Eun S; Chung, Sun G; Kim, Tae Uk; Kim, Hee Chan

    2012-12-01

    To investigate whether capsule-preserving hydraulic distension with saline solution and corticosteroid for adhesive capsulitis induces biomechanical alterations in glenohumeral joint capsules along with clinical improvements. A case series. University outpatient clinic of physical medicine and rehabilitation. Eighteen patients with unilateral adhesive capsulitis. INTERVENTION AND MAIN OUTCOME MEASUREMENTS: Three hydraulic distensions with saline solution and corticosteroid were performed with 1-month intervals. To avoid rupturing capsules, all distensions were monitored by using real-time pressure-volume curves. Stiffness, maximal volume capacity, and pressure at the maximal volume capacity of the capsule were measured at each intervention. Clinical parameters, such as pain and range of motion, were recorded before, 3 days after, and 1 month after each distension. Stiffness decreased (47.6 ± 27.1 mm Hg/mL to 31.7 ± 18.4 mm Hg/mL to 24.2 ± 14.0 mm Hg/mL, mean SD) and maximal volume capacity increased (18.8 ± 7.3 mL to 20.5 ± 7.5 mL to 24.2 ± 7.0 mL, mean SD) significantly (P = .001 for both) at each repeated hydraulic distension. Pressure at the maximal volume capacity tended to decrease, but the decrements were not statistically significant (P = .662). The clinical parameters were significantly improved throughout and 1 month after the 3 repeat procedures (P Capsule-preserving hydraulic distension changed the biomechanical properties of the glenohumeral joint capsule, lessening the stiffness and enlarging the volume capacity. These alterations were accompanied by improved range of motion and relief of pain. Repeated capsule-preserving hydraulic distension with saline solution and corticosteroid would be useful to treat adhesive capsulitis and to evaluate the treatment results. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  15. Capsule Shields the Function of Short Bacterial Adhesins

    OpenAIRE

    Schembri, Mark A.; Dalsgaard, Dorte; Klemm, Per

    2004-01-01

    Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can occur in other gram-negative bacteria. Likewise, we show that other short adhesins exemplified by the AIDA-I protein are blocked by the presence of a capsule. The results support the notion that cap...

  16. Adhesive Capsulitis in 8 Dogs: Diagnosis and Management

    OpenAIRE

    Brittany Jean Carr; Sherman Orye Canapp; Debra A Canapp; Lauri-Jo Gamble; David L Dycus

    2016-01-01

    ABSTRACT:Objective: To describe clinical and diagnostic findings as well as management of adhesive capsulitis in dogs.Background: Adhesive capsulitis, also known as frozen shoulder, is a syndrome defined by loss of range of motion of the shoulder and may be the end-stage manifestation of several primary conditions.Evidentiary Value: This is a case report series of eight dogs with chronic forelimb lameness diagnosed with adhesive capsulitis.Methods: Medical records (June 1, 2010 to September...

  17. Adhesive Capsulitis in Eight Dogs: Diagnosis and Management

    OpenAIRE

    Carr, Brittany J.; Canapp, Sherman O.; Canapp, Debra A.; Gamble, Lauri-Jo; Dycus, David L.

    2016-01-01

    Objective To describe clinical and diagnostic findings as well as management of adhesive capsulitis in dogs. Background Adhesive capsulitis, also known as frozen shoulder, is a syndrome defined by loss of range of motion of the shoulder and may be the end-stage manifestation of several primary conditions. Evidentiary Value This is a case series report of eight dogs with chronic forelimb lameness diagnosed with adhesive capsulitis. Methods Medical records (June 1, 20...

  18. Production, deformation and mechanical investigation of magnetic alginate capsules

    Science.gov (United States)

    Zwar, Elena; Kemna, Andre; Richter, Lena; Degen, Patrick; Rehage, Heinz

    2018-02-01

    In this article we investigated the deformation of alginate capsules in magnetic fields. The sensitivity to magnetic forces was realised by encapsulating an oil in water emulsion, where the oil droplets contained dispersed magnetic nanoparticles. We solved calcium ions in the aqueous emulsion phase, which act as crosslinking compounds for forming thin layers of alginate membranes. This encapsulating technique allows the production of flexible capsules with an emulsion as the capsule core. It is important to mention that the magnetic nanoparticles were stable and dispersed throughout the complete process, which is an important difference to most magnetic alginate-based materials. In a series of experiments, we used spinning drop techniques, capsule squeezing experiments and interfacial shear rheology in order to determine the surface Young moduli, the surface Poisson ratios and the surface shear moduli of the magnetically sensitive alginate capsules. In additional experiments, we analysed the capsule deformation in magnetic fields. In spinning drop and capsule squeezing experiments, water droplets were pressed out of the capsules at elevated values of the mechanical load. This phenomenon might be used for the mechanically triggered release of water-soluble ingredients. After drying the emulsion-filled capsules, we produced capsules, which only contained a homogeneous oil phase with stable suspended magnetic nanoparticles (organic ferrofluid). In the dried state, the thin alginate membranes of these particles were rather rigid. These dehydrated capsules could be stored at ambient conditions for several months without changing their properties. After exposure to water, the alginate membranes rehydrated and became flexible and deformable again. During this swelling process, water diffused back in the capsule. This long-term stability and rehydration offers a great spectrum of different applications as sensors, soft actuators, artificial muscles or drug delivery systems.

  19. [Acanthamoeba isolation from contact lens solution of contact lens wearers without keratitis].

    Science.gov (United States)

    Watanabe, R; Ishibashi, Y; Hommura, S; Ishii, K

    1994-05-01

    Acanthamoeba keratitis seems to be associated with wearing contact lenses. As controls, we surveyed contact lens wearers without keratitis. Contact lens solutions of 93 persons were examined in order to identify risk factors for contamination by Acanthamoeba. Therefore, the contact lens disinfection system and storage schedules were studied in each case. Acanthamoeba organisms were isolated from 4 specimens (4.3%). The incidence of Acanthamoeba was higher in specimens of soft contact lens solution than in those of hard contact lens solution, and all the Acanthamoeba positive cases had been using tap water.

  20. Capsule irradiation tests of non-fissile materials in HANARO

    International Nuclear Information System (INIS)

    Choo, K. N.; Sohn, J. M.; Kim, B. G.; Shin, Y. T.; Oh, J. M.; Lim, I. C.; Kang, Y. H.

    2003-01-01

    The R and D programs on the nuclear reactor materials require numerous in-pile tests in HANARO. Extensive efforts have been made to establish design and manufacturing technology for the development of irradiation facilities. Material capsule and rabbit(small non-instrumented capsule) systems were developed for the irradiation test of non fissile materials in HANARO. Several irradiation capsules (8 instrumented and 2 non-instrumented capsules) and rabbits(17 rabbits) has been designed, fabricated and successfully irradiated in HANARO CT, IR, HTS or IP test holes since 1995. Capsules were designed for the irradiation of RPV (Reactor Pressure Vessel), reactor core materials, and Zr-based alloys. Most capsules were made for KAERI material research projects, but 3 capsules were made as a part of national projects for the promotion of HANARO utilization. Rabbits were used for the irradiation of semi-conductors(Si, Sapphire) and magnetic materials. 3,300 specimens from domestic 13 research institutes, 2 nuclear industry companies and 51 universities, were irradiated in HANARO for 26,000 hours using capsule and rabbit irradiation systems. Through this research, the nuclear characteristics of HANARO capsules and rabbits were also produced and piled up in our database

  1. Capsule shields the function of short bacterial adhesins

    DEFF Research Database (Denmark)

    Schembri, Mark; Dalsgaard, D.; Klemm, Per

    2004-01-01

    occur in other gram-negative bacteria. Likewise, we show that other short adhesins exemplified by the AIDA-I protein are blocked by the presence of a capsule. The results support the notion that capsule polysaccharides sterically prevent receptor-target recognition of short bacterial adhesins......Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can....... This negative interference has important biological consequences, such as affecting the ability of bacteria to form biofilms....

  2. Protection of the eye lens

    International Nuclear Information System (INIS)

    2015-01-01

    The limit of radiation exposure for eye lens is going to decrease dramatically from 150 to 20 mSv as a transposition into the French law of a CIPR (International Commission for Radiation Protection) directive. Sanitary studies have shown that radiologists are more likely by a factor of 3.8 to get eye lens opacities than the rest of the population. The wearing of protective glasses is recommended and in order to get a better monitoring of the radiation dose new dosimeters have been designed, they can be worn on the glass frame of directly stuck on the skin near the eyes. A study has shown that veterinary surgeons that are accustomed to stay near animals to keep them quiet during radiological exams are prone to receive high doses as well as physicians that use hypnosis to decrease the level of anxiety of their patients during radiological exams. Radiation exposure of radiologists can be mitigated through: the use of protective shields and equipment and the optimization of the dose delivered to the patient. (A.C.)

  3. Introduction to the physics of ICF capsules

    International Nuclear Information System (INIS)

    Lindl, J.D.

    1989-01-01

    Inertial Confinement Fusion is an approach to fusion which relies on the inertia of the fuel mass to provide confinement. To achieve conditions under which this confinement is sufficient for efficient thermonuclear burn, high gain ICF targets designed to be imploded directly by laser light. These capsules are generally a spherical shell which is filled with low density DT gas. The shell is composed of an outer region which forms the ablator and an inner region of frozen or liquid DT which forms the main fuel. Energy from the driver is delivered to the ablator which heats up and expands. As the ablator expands and blows outward, the rest of the shell is forced inward to conserve momentum. In this implosion process, several features are important. We define the in-flight-aspect-ratio (IFAR) as the ratio of the shell radius R as it implodes to its thickness ΔR. Hydrodynamic instabilities during the implosion impose limits on this ratio which results in a minimum pressure requirement of about 100 Mbar. The convergence ratio is defined as the ratio of the initial outer radius of the ablator to the final compressed radius of the hot spot. This hot spot is the central region of the compressed fuel which is required to ignite the main fuel in high gain designs. Typical convergence ratios are 30--40. To maintain a nearly spherical shape during the implosion, when convergence ratios are this large, the flux delivered to the capsule must be uniform to a few percent. The remainder of this paper discusses the conditions necessary to achieve thermonuclear ignition in these ICF capsules

  4. Effectiveness of corticosteroid injection in adhesive capsulitis.

    Science.gov (United States)

    Bal, Ajda; Eksioglu, Emel; Gulec, Berna; Aydog, Ece; Gurcay, Eda; Cakci, Aytul

    2008-06-01

    To assess whether intraarticular corticosteroids improve the outcome of a comprehensive home exercise programme in patients with adhesive capsulitis. The study was undertaken in the Physical Therapy and Rehabilitation Department of a Ministry of Health hospital in Turkey. Eighty patients with adhesive capsulitis were enrolled in the study. The patients were randomly assigned to two groups: Group 1 patients were given intraarticular corticosteroid (1 mL, 40 mg methylprednisolone acetate) followed by a 12-week comprehensive home exercise programme. Group 2 patients were given intraarticular serum physiologic (1 mL solution of 0.9% sodium chloride) followed by a 12-week comprehensive home exercise programme. The outcome parameters were Shoulder Pain and Disability Index and University of California-Los Angeles end-result scores, night pain and shoulder passive range of motion. Mean actual changes in abduction range of motion, Shoulder Pain and Disability Index-total score and Shoulder Pain and Disability Index-pain score were statistically different between the two groups at the second week, with the better scores determined in group 1. However, there were no significant differences between the groups at the 12th week. Medians of University of California-Los Angeles scores in the second week were significantly different between the two groups (P = 0.02), with better scores in group 1; however, the difference in 12th week scores was insignificant. Intraarticular corticosteroids have the additive effect of providing rapid pain relief, mainly in the first weeks of the exercise treatment period. In patients with adhesive capsulitis who have pain symptom predominantly, intraarticular corticosteroid therapy could be advised concomitantly with exercise.

  5. Campylobacter polysaccharide capsules: virulence and vaccines

    Directory of Open Access Journals (Sweden)

    Patricia eGuerry

    2012-02-01

    Full Text Available Campylobacter jejuni remains a major cause of bacterial diarrhea worldwide and is associated with numerous sequelae, including Guillain Barre Syndrome, inflammatory bowel disease, reactive arthritis, and irritable bowel syndrome. C. jejuni is unusual for an intestinal pathogen in its ability to coat its surface with a polysaccharide capsule (CPS. These capsular polysaccharides vary in sugar composition and linkage, especially those involving heptoses of unusual configuration and O-methyl phosphoramidate linkages. This structural diversity is consistent with CPS being the major serodeterminant of the Penner scheme, of which there are 47 C. jejuni serotypes. Both CPS expression and expression of modifications are subject to phase variation by slip strand mismatch repair. Although capsules are virulence factors for other pathogens, the role of CPS in C. jejuni disease has not been well defined beyond descriptive studies demonstrating a role in serum resistance and for diarrhea in a ferret model of disease. However, perhaps the most compelling evidence for a role in pathogenesis are data that CPS conjugate vaccines protect against diarrheal disease in non-human primates. A CPS conjugate vaccine approach against this pathogen is intriguing, but several questions need to be addressed, including the valency of CPS types required for an effective vaccine. There have been numerous studies of prevalence of CPS serotypes in the developed world, but few studies from developing countries where the disease incidence is higher. The complexity and cost of Penner serotyping has limited its usefulness, and a recently developed multiplex PCR method for determination of capsule type offers the potential of a more rapid and affordable method. Comparative studies have shown a strong correlation of the two methods and studies are beginning to ascertain CPS-type distribution worldwide, as well as examination of correlation of severity of illness with specific CPS types.

  6. Chromoendoscopy in magnetically guided capsule endoscopy

    Science.gov (United States)

    2013-01-01

    Background Diagnosis of intestinal metaplasia and dysplasia via conventional endoscopy is characterized by low interobserver agreement and poor correlation with histopathologic findings. Chromoendoscopy significantly enhances the visibility of mucosa irregularities, like metaplasia and dysplasia mucosa. Magnetically guided capsule endoscopy (MGCE) offers an alternative technology for upper GI examination. We expect the difficulties of diagnosis of neoplasm in conventional endoscopy to transfer to MGCE. Thus, we aim to chart a path for the application of chromoendoscopy on MGCE via an ex-vivo animal study. Methods We propose a modified preparation protocol which adds a staining step to the existing MGCE preparation protocol. An optimal staining concentration is quantitatively determined for different stain types and pathologies. To that end 190 pig stomach tissue samples with and without lesion imitations were stained with different dye concentrations. Quantitative visual criteria are introduced to measure the quality of the staining with respect to mucosa and lesion visibility. Thusly determined optimal concentrations are tested in an ex-vivo pig stomach experiment under magnetic guidance of an endoscopic capsule with the modified protocol. Results We found that the proposed protocol modification does not impact the visibility in the stomach or steerability of the endoscopy capsule. An average optimal staining concentration for the proposed protocol was found at 0.4% for Methylene blue and Indigo carmine. The lesion visibility is improved using the previously obtained optimal dye concentration. Conclusions We conclude that chromoendoscopy may be applied in MGCE and improves mucosa and lesion visibility. Systematic evaluation provides important information on appropriate staining concentration. However, further animal and human in-vivo studies are necessary. PMID:23758801

  7. A and B mode ultrasonography in preoperative evaluation of lens and posterior segment of dogs eyes with cataract

    Directory of Open Access Journals (Sweden)

    Bianca C. Martins

    2010-02-01

    Full Text Available Ultrasonography of the lens and posterior segment is an indispensable step in the preoperative evaluation of dogs with cataracts, since ophthalmoscopy is not feasible when there is opacification of the lens. This study evaluated the echographic conditions of cataractous lens and fundus of the eye in dogs affected by cataracts. The study was conducted in 30 dogs (56 eyes, 10 males and 20 females, with different types of cataracts at different stages of development. Echography in A and B modes, simultaneously, was carried out for the examination of the lens and posterior segment. The examinations revealed anterior cortical, posterior cortical and nuclear cataract in 12 eyes (21.4%, anterior cortical, posterior cortical, nuclear and posterior capsular in 23 eyes (41%, anterior cortical, posterior cortical and posterior capsular cataract in one eye (1.7%, anterior cortical and nuclear cataract in one eye (1.7%, anterior cortical, nuclear and posterior capsular cataract in five eyes (8.9%, and anterior cortical cataract in seven eyes (12.5%. Abnormal ultrasonographic alterations were observed in the posterior segment in 26 eyes evaluated (46.4%. Vitreal degeneration was detected in 12 eyes (21.4%, images of vitreal exudate or hemorrhage in seven eyes (12.5%, persistence of hyaloid artery in four eyes (7.1% and lens subluxation in three eyes (5.3%. The results obtained reiterate the importance of ultrasonography in canine patients presented for cataract surgery given that alterations of the posterior segment are difficult to identify in a clinical examination when the lens is opacified.A ultrassonografia do segmento posterior do bulbo do olho é etapa indispensável na avaliação de cães com catarata que serão submetidos à facectomia, uma vez que a oftalmoscopia não é factível quando há opacificação da lente, notadamente nas cataratas maduras. Este estudo avaliou as condições ecográficas da lente cataratogênica e do fundo de olho de c

  8. Color corrected Fresnel lens for solar concentration

    International Nuclear Information System (INIS)

    Kritchman, E.M.

    1979-01-01

    A new linear convex Fresnel lens with its groove side down is described. The design philosophy is similar to the highly concentrating two focal Fresnel lens but including a correction for chromatic aberration. A solar concentration ratio as high as 80 is achieved. For wide acceptance angles the concentration nears the theoretical maximum. (author)

  9. Charged black lens in de Sitter space

    Science.gov (United States)

    Tomizawa, Shinya

    2018-02-01

    We obtain a charged black lens solution in the five-dimensional Einstein-Maxwell-Chern-Simons theory with a positive cosmological constant. It is shown that the solution obtained here describes the formation of a black hole with the spatial cross section of a sphere from that of the lens space of L (n ,1 ) in five-dimensional de Sitter space.

  10. Postirradiation examination of capsule GF-4. [HTGR

    Energy Technology Data Exchange (ETDEWEB)

    Kovacs, W.J.; Sedlak, B.J.

    1980-10-01

    The GF-4 capsule test was irradiated in the SILOE reactor at Grenoble, France between April 8, 1975 and July 26, 1976. High-enriched uranium (HEU) UC/sub 2/ and weak acid resin (WAR) UC/sub x/O/sub y/ fissile and ThO/sub 2/ fertile particles were tested. Postirradiation examination of cured-in-place fuel rods showed no fuel rod/graphite element interaction. In addition, all rods exhibited adequate structural integrity. Irradiation-induced dimensional changes for rods containing all TRISO-coated fuel were consistent with model predictions; however, rods containing BISO-coated fuel exhibited greater volumetric contractions than predicted.

  11. Postirradiation examination of capsule GF-4

    International Nuclear Information System (INIS)

    Kovacs, W.J.; Sedlak, B.J.

    1980-10-01

    The GF-4 capsule test was irradiated in the SILOE reactor at Grenoble, France between April 8, 1975 and July 26, 1976. High-enriched uranium (HEU) UC 2 and weak acid resin (WAR) UC/sub x/O/sub y/ fissile and ThO 2 fertile particles were tested. Postirradiation examination of cured-in-place fuel rods showed no fuel rod/graphite element interaction. In addition, all rods exhibited adequate structural integrity. Irradiation-induced dimensional changes for rods containing all TRISO-coated fuel were consistent with model predictions; however, rods containing BISO-coated fuel exhibited greater volumetric contractions than predicted

  12. C5 capsule operation modes analysis

    International Nuclear Information System (INIS)

    Negut, Gh.; Ancuta, Mirela; Stefan, Violeta

    2008-01-01

    This paper is part of the Nuclear Research Institute Program 13 dedicated to 'TRIGA Research Reactor performance enhancing' and its objective is improving the engineering of the structural materials irradiation. The paper raises the knowledge level on C5 capsule irradiation modes and utilizes previous results in order to increase C5 performances. In the paper the irradiation modes to test zirconium yttrium sample are assessed. These tests are proposed by AECL. There are presented the C5 initial conditions and models. Also. there are presented the thermal hydraulic conditions during normal and accidental operation. The results will be used in the C5 safety report. (authors)

  13. Characterization of an aged WESF capsule

    International Nuclear Information System (INIS)

    Kenna, B.T.; Schultz, F.J.

    1983-07-01

    A joint effort by SNLA and ORNL was initiated for a detailed characterization of an 18-year-old WESF 137 Cs source which has been used in the Sandia Irradiator for Dried Sewage Solids. The study included evaluation of the inner and outer stainless steel capsules by optical metallography, electron microprobe, and physical testing. Analysis of the residual atmospheres within the two containers was also done. The CsCl was analyzed for isotopic content and impurities. No potential problem areas, including corrosion, were found

  14. Automatic blood detection in capsule endoscopy video

    Science.gov (United States)

    Novozámský, Adam; Flusser, Jan; Tachecí, Ilja; Sulík, Lukáš; Bureš, Jan; Krejcar, Ondřej

    2016-12-01

    We propose two automatic methods for detecting bleeding in wireless capsule endoscopy videos of the small intestine. The first one uses solely the color information, whereas the second one incorporates the assumptions about the blood spot shape and size. The original idea is namely the definition of a new color space that provides good separability of blood pixels and intestinal wall. Both methods can be applied either individually or their results can be fused together for the final decision. We evaluate their individual performance and various fusion rules on real data, manually annotated by an endoscopist.

  15. Reducing redundancy in wireless capsule endoscopy videos.

    Science.gov (United States)

    Lee, Hyun-Gyu; Choi, Min-Kook; Shin, Byeong-Seok; Lee, Sang-Chul

    2013-07-01

    We eliminate similar frames from a wireless capsule endoscopy video of the human intestines to maximize spatial coverage and minimize the redundancy in images. We combine an intensity correction method with a method based an optical flow and features to detect and reduce near-duplicate images acquired during the repetitive backward and forward egomotions due to peristalsis. In experiments, this technique reduced duplicate image of 52.3% from images of the small intestine. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  16. Contact Lens Use in the Civil Airman Population

    National Research Council Canada - National Science Library

    Nakagawara, Van

    2002-01-01

    ...) aeromedical certificate. Although contact lens technology has advanced dramatically in recent years, the aviation environment may still have adverse effects on contact lens performance in some flight situations...

  17. Corrected electrostatic lens systems for ion beams

    International Nuclear Information System (INIS)

    Dalgish, R.L.

    1981-01-01

    Recent work in our laboratory has introduced a new class of electrostatic focus forming element for beams, the ELCO lens. It compares favourably with the electrostatic and magnetic quadrupole elements conventionally used for microbeam formation. The ELCO lens does however have disadvantages associated with apertures and alignment. We have continued with the development of ion beam lenses and have evolved a further class of lens element which eliminates aperture and alignment problems. This new element can be combined like optical lenses into an aberration corrected system. Experimental measurement on the basic lens element has confirmed mathematical analysis of ion trajectories through the element. This mathematical analysis predicts that the basic element can be combined into a corrected lens system for, either: (1) high resolution microprobe formation with intrinsic rastering ability, the spot size limited only by the beam properties; or (2) high quality image formation with large magnification/demagnification ratio and wide angular aperture. (orig.)

  18. Spontaneous, late, in-the-bag intraocular lens subluxation in a patient with a previous acute angle-closure glaucoma attack.

    Science.gov (United States)

    Su, Wei-Wen; Chang, Shirley H L

    2004-08-01

    Cataract surgery was performed in a 49-year-old woman 16 months after an acute angle-closure glaucoma attack. Zonular dialysis was observed during surgery, but the intraocular lens (IOL) was implanted in the capsular bag uneventfully. At 4 1/2 months, 1 IOL loop wrapped in the bag herniated into the anterior chamber. The patient had no history of trauma. The IOL loop remained in the anterior chamber for 9 months, until the subluxated IOL spontaneously returned to its original position. Six months later, the IOL again dislocated into the anterior chamber.

  19. Inestabilidad Anterior de Hombro

    Directory of Open Access Journals (Sweden)

    Pablo David Flint Kuran

    2013-11-01

    Full Text Available In­tro­duc­ción La luxación recidivante de hombro es una patología frecuente en pacientes jóvenes, laboralmente activos. Existen numerosas técnicas quirúrgicas para la inestabilidad glenohumeral. La técnica de Bristow, discutida por no ser anatómica y por sus complicaciones, continúa vigente debido al bajo índice de reluxaciones. Los objetivos fueron determinar el índice de recidiva, alteraciones funcionales e índice de consolidación del injerto. Materiales­ y­ Métodos Se evaluaron 24 pacientes del sexo masculino, de entre 19 y 40 años, operados por luxación anterior recidivante de hombro según la técnica de Bristow, entre enero de 2003 y agosto de 2011. Se evaluó la tasa de reluxación, la función articular según el puntaje de Constant y el posicionamiento del injerto con respecto a la superficie articular con tomografía y radiografías para evaluar la consolidación del injerto. Se registraron las complicaciones quirúrgicas. Resultados ­Todos los pacientes eran hombres, con rango de edad de 19 a 40 años. La causa fue traumática en 24 pacientes. Dieciséis pacientes presentaron más de 3 episodios de luxación prequirúrgicos. Según la escala de Constant, 21 obtuvieron entre 96 y 100 puntos, y los restantes, entre 90 y 95 puntos. No hubo nuevos episodios de luxaciones. La tomografía mostró la consolidación en todos los casos. Un paciente tuvo una imagen osteolítica alrededor del tornillo, sin compromiso funcional del hombro. Conclusión La técnica de Bristow para tratar la luxación anterior recidivante de hombro provocó un bajo índice de complicaciones, con resultados funcionales entre excelentes y buenos. No hubo episodios de reluxación y se logró la consolidación del injerto óseo en todos los casos.

  20. Potential value of Cs-137 capsules

    Energy Technology Data Exchange (ETDEWEB)

    Bloomster, C.H.; Brown, D.R.; Bruno, G.A.; Hazelton, R.F.; Hendrickson, P.L.; Lezberg, A.J.; Tingey, G.L.; Wilfert, G.L.

    1985-04-01

    We determined the value of Cs-137 compared to Co-60 as a source for the irradiation of fruit (apples and cherries), pork and medical supplies. Cs-137, in the WESF capsule form, had a value of approximately $0.40/Ci as a substitute for Co-60 priced at approximately $1.00/Ci. The comparison was based on the available curies emitted from the surface of each capsule. We developed preliminary designs for fourteen irradiation facilities; seven were based on Co-60 and seven were based on Cs-137. These designs provided the basis for estimating capital and operating costs which, in turn, provided the basis for determining the value of Cs-137 relative to Co-60 in these applications. We evaluated the effect of the size of the irradiation facility on the value of Cs-137. The cost of irradiation is low compared to the value of the product. Irradiation of apples for disinfestation costs $.01 to .02 per pound. Irradiation for trichina-safe pork costs $.02 per pound. Irradiation of medical supplies for sterilization costs $.07 to .12 per pound. The cost of the irradiation source, either Co-60 or Cs-137, contributed only a minor amount to the total cost of irradiation, about 5% for the fruit and hog cases and about 20% for the medical supply cases. We analyzed the sensitivity of the irradiation costs and Cs-137 value to several key assumptions.

  1. TREATMENT PROTOCOLS OF ADHESIVE CAPSULITIS - METANALYSIS

    Directory of Open Access Journals (Sweden)

    Alisson Guimbala dos Santos Araujo

    2013-04-01

    Full Text Available Introduction: The adhesive capsulitis (AC is an idiopathic disorder that affects about 3-5% of the general population, the majority being aged 50 years. It is divided into three stages: acute or hiperálgica, rigidity phase or stage of freezing and thawing. This study aimed to analyze the protocols of treatments for adhesive capsulitis. Methods: We performed literature search in electronic databases, BIREME, SciELO, LILACS and PubMed. We analyzed 20 articles of which seven met the inclusion criteria of this study. Results: Of the 20 articles analyzed, it was found that only seven had controlled clinical trials, and the articles selected for the treatment of AC were: medication and physiotherapy, manipulation, hydraulic distension, serials suprascapular nerve blocks, acupuncture, exercise, physiotherapy and nonsteroidal anti-inflammatory therapy dynasplint, deep friction massage and wave diathermy. Conclusion: As noted in the studies, there is a range of treatments that have proven effective for AC, failing to come to a conclusion of what would be the most appropriate treatment. However it was noted that physiotherapy through kinesiotherapy remains the best option, and the earlier therapeutic intervention performed, the better the results.

  2. Corticosteroid Injections for Adhesive Capsulitis: A Review.

    Science.gov (United States)

    Xiao, Ryan C; Walley, Kempland C; DeAngelis, Joseph P; Ramappa, Arun J

    2017-05-01

    Adhesive capsulitis is a self-limiting condition in a majority of patients and is often treated nonoperatively. However, symptoms may take 2 to 3 years to resolve fully. A small, but significant, portion of patients require surgical intervention. The purpose of this systematic review is to evaluate the efficacy of corticosteroid injections for the treatment of adhesive capsulitis (AC). A review of articles indexed by the United States National Library of Medicine was conducted by querying the PubMed database for studies involving participants with AC, frozen shoulder, stiff shoulder, or painful shoulder. Articles that included corticosteroids, glucocorticoids, steroids, and injections were included. Corticosteroid injections provide significant symptom relief for 2 to 24 weeks. Injections can be performed intra-articularly or into the subacromial space. Evidence suggests that a 20 mg dose of triamcinolone may be as effective as a 40 mg injection. It remains unclear whether image-guided injections produce a clinically significant difference in outcomes when compared with landmark-guided (blind) injections. Corticosteroids may be less beneficial for diabetic patients. Patients using protease inhibitors (antiretroviral therapy) should not receive triamcinolone because the drug-drug interaction may result in iatrogenic Cushing syndrome. Corticosteroid injections for AC demonstrate short-term efficacy, but may not provide a long-term benefit. More high quality, prospective studies are needed to determine whether corticosteroid injections using ultrasound guidance significantly improve outcomes.

  3. Isotretinoin Oil-Based Capsule Formulation Optimization

    Directory of Open Access Journals (Sweden)

    Pi-Ju Tsai

    2013-01-01

    Full Text Available The purpose of this study was to develop and optimize an isotretinoin oil-based capsule with specific dissolution pattern. A three-factor-constrained mixture design was used to prepare the systemic model formulations. The independent factors were the components of oil-based capsule including beeswax (X1, hydrogenated coconut oil (X2, and soybean oil (X3. The drug release percentages at 10, 30, 60, and 90 min were selected as responses. The effect of formulation factors including that on responses was inspected by using response surface methodology (RSM. Multiple-response optimization was performed to search for the appropriate formulation with specific release pattern. It was found that the interaction effect of these formulation factors (X1X2, X1X3, and X2X3 showed more potential influence than that of the main factors (X1, X2, and X3. An optimal predicted formulation with Y10 min, Y30 min, Y60 min, and Y90 min release values of 12.3%, 36.7%, 73.6%, and 92.7% at X1, X2, and X3 of 5.75, 15.37, and 78.88, respectively, was developed. The new formulation was prepared and performed by the dissolution test. The similarity factor f2 was 54.8, indicating that the dissolution pattern of the new optimized formulation showed equivalence to the predicted profile.

  4. Petrous bone fractures violating otic capsule.

    Science.gov (United States)

    Magliulo, Giuseppe; Ciniglio Appiani, Mario; Iannella, Giannicola; Artico, Marco

    2012-12-01

    This study presents our experience with a series of patients suffering from petrous bone fractures violating the otic capsule who underwent subtotal petrosectomy combined with eustachian tube, middle ear, and mastoid obliteration, with the goal of preventing cerebrospinal fluid (CSF) leak and meningitis. This study enrolled 26 patients between 1997 and 2011. The clinical symptoms, otoscopy, and preoperative and postoperative audiometry and facial function, as well as CSF leak or meningitis, were evaluated in each patient. The entire group underwent a subtotal petrosectomy using the technique described in detail by Fisch. In addition, each patient was interviewed using a questionnaire to evaluate the impact on quality of life. Intraoperatively, we found significant CSF leaks in 14 patients (42.5%). No patient reported other episodes of CSF leak or meningitis after the surgery. The patients' responses of facial nerve function were slightly worse than the House-Brackmann evaluation (50% versus 42.3%; p < 0.05). The vast majority (88.5%) of the patients experienced no social impact. Our findings suggest the importance of not underestimating the risk for CSF leak in the petrous bone fractures violating the otic capsule. Preoperative counseling regarding the various troublesome complications must adequately motivate candidates to undergo surgery by pointing out the positive impact of the proposed treatment.

  5. Potential value of Cs-137 capsules

    International Nuclear Information System (INIS)

    Bloomster, C.H.; Brown, D.R.; Bruno, G.A.; Hazelton, R.F.; Hendrickson, P.L.; Lezberg, A.J.; Tingey, G.L.; Wilfert, G.L.

    1985-04-01

    We determined the value of Cs-137 compared to Co-60 as a source for the irradiation of fruit (apples and cherries), pork and medical supplies. Cs-137, in the WESF capsule form, had a value of approximately $0.40/Ci as a substitute for Co-60 priced at approximately $1.00/Ci. The comparison was based on the available curies emitted from the surface of each capsule. We developed preliminary designs for fourteen irradiation facilities; seven were based on Co-60 and seven were based on Cs-137. These designs provided the basis for estimating capital and operating costs which, in turn, provided the basis for determining the value of Cs-137 relative to Co-60 in these applications. We evaluated the effect of the size of the irradiation facility on the value of Cs-137. The cost of irradiation is low compared to the value of the product. Irradiation of apples for disinfestation costs $.01 to .02 per pound. Irradiation for trichina-safe pork costs $.02 per pound. Irradiation of medical supplies for sterilization costs $.07 to .12 per pound. The cost of the irradiation source, either Co-60 or Cs-137, contributed only a minor amount to the total cost of irradiation, about 5% for the fruit and hog cases and about 20% for the medical supply cases. We analyzed the sensitivity of the irradiation costs and Cs-137 value to several key assumptions

  6. Quality evaluation of simvastatin compounded capsules

    Directory of Open Access Journals (Sweden)

    Flávia Dias Marques-Marinho

    2011-09-01

    Full Text Available Simvastatin is commercially available as tablets and compounded capsules in Brazil. Very few reports regarding these capsules' quality, and consequently their efficacy, are available. The pharmaceutical quality of 30 batches of 20 mg simvastatin capsules from the market was evaluated by weight determination, content uniformity, disintegration (Brazilian Pharmacopeia, assay and dissolution test (USP32 tablet monograph. A HPLC method was developed for assay, content uniformity and dissolution test, and specifications were also established. Out of the 30 batches evaluated, 29 showed capsule disintegration within 45 min and individual weight variation was within ±10% or ±7.5% relative to average weight, for 300 mg, respectively. Only 27 batches met dissolution test criteria with values >80% of the labeled amount in 45 min; 21 batches showed simvastatin content between 90.0-110.0% of the labeled amount and 19 batches had at least 9 out of 10 capsules with content uniformity values between 85.0-115.0% of the labeled amount with RSDNo Brasil, a sinvastatina está comercialmente disponível na forma de comprimidos e cápsulas manipuladas. Poucos relatos estão disponíveis sobre a qualidade e, consequentemente, a eficácia dessas cápsulas. A qualidade de 30 lotes de sinvastatina 20 mg cápsulas do mercado foi avaliada através da determinação de peso, uniformidade de conteúdo, desintegração (Farmacopéia Brasileira, doseamento e teste de dissolução (monografia comprimidos USP32. Método por CLAE foi desenvolvido para o doseamento, uniformidade de conteúdo e teste de dissolução; além disso, especificações foram estabelecidas. Dos 30 lotes avaliados, 29 apresentaram desintegração da cápsula até 45 min e a variação do peso individual foi ± 10% ou ± 7,5% em relação ao peso médio, se 300 mg, respectivamente. Apenas 27 lotes preencheram os critérios do teste de dissolução com valores > 80% da quantidade rotulada, em 45 min, 21

  7. Incidence of irregular astigmatism eligible for contact lens fitting after Descemet membrane endothelial keratoplasty.

    Science.gov (United States)

    van Dijk, Korine; Parker, Jack; Liarakos, Vasilios S; Ham, Lisanne; Frank, Laurence E; Melles, Gerrit R J

    2013-07-01

    To evaluate the incidence and causes of anterior corneal surface irregularities after successful Descemet membrane endothelial keratoplasty (DMEK) and the efficacy of contact lens fitting in these cases. Tertiary referral center. Retrospective study of prospectively collected data. Eyes with a subnormal visual outcome or monocular diplopia after successful DMEK were fitted with a contact lens. These cases were evaluated with Pentacam rotating Scheimpflug camera imaging preoperatively and 6 months postoperatively, and outcomes were compared with those in a randomly selected DMEK control group. In a series of 262 surgeries, 23 eyes (21 patients) were fitted with contact lenses; the control group comprised 23 eyes. Indications for contact lens fitting included (1) obvious corneal surface irregularities due to preexisting corneal scarring, (2) surface irregularities associated with longstanding preoperative stromal edema, and (3) undetectable optical imperfections. The postoperative corrected distance visual acuity (CDVA) with spectacles improved after contact lens correction (PDutch Ophthalmic USA. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Directory of Open Access Journals (Sweden)

    M Isabel Canut Jordana

    2010-11-01

    Full Text Available M Isabel Canut Jordana1, Daniel Pérez Formigó1, Rodrigo Abreu González2, Jeroni Nadal Reus11Barraquer Ophthalmology Centre, Barcelona, Spain; 2University Hospital of La Candelaria, Tenerife, SpainAims: We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact.Methods: Complete ophthalmologic examination and optical coherence tomography (OCT of the anterior segment were performed.Results: Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control.Conclusion: Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.Keywords: pigmentary glaucoma, intraocular lens, optical coherence tomography, laser

  9. Anterior ankle arthrodesis

    Science.gov (United States)

    Slater, Gordon L; Sayres, Stephanie C; O’Malley, Martin J

    2014-01-01

    Ankle arthrodesis is a common procedure that resolves many conditions of the foot and ankle; however, complications following this procedure are often reported and vary depending on the fixation technique. Various techniques have been described in the attempt to achieve ankle arthrodesis and there is much debate as to the efficiency of each one. This study aims to evaluate the efficiency of anterior plating in ankle arthrodesis using customised and Synthes TomoFix plates. We present the outcomes of 28 ankle arthrodeses between 2005 and 2012, specifically examining rate of union, patient-reported outcomes scores, and complications. All 28 patients achieved radiographic union at an average of 36 wk; the majority of patients (92.86%) at or before 16 wk, the exceptions being two patients with Charcot joints who were noted to have bony union at a three year review. Patient-reported outcomes scores significantly increased (P plate offers added compression and provides a rigid fixation for arthrodesis stabilization. PMID:24649408

  10. Cuba Through A New Lens

    Directory of Open Access Journals (Sweden)

    Jean Stubbs

    2008-12-01

    Full Text Available [First paragraph] The Origins of the Cuban Revolution Reconsidered. Samuel Farber. Chapel Hill: University of North Carolina Press, 2006. x + 212 pp. (Paper US$ 19.95 Cuba: A New History. Ric hard Gott . New Haven: Yale University Press, 2005. xii + 384 pp. (Paper US$ 17.00 Havana: The Making of Cuban Culture. Antoni Kapcia. Oxford: Berg Publishers, 2005. xx + 236 pp. (Paper US$ 24.95 Richard Gott, Antoni Kapcia, and Samuel Farber each approach Cuba through a new lens. Gott does so by providing a broad-sweep history of Cuba, which is epic in scope, attaches importance to social as much as political and economic history, and blends scholarship with flair. Kapcia homes in on Havana as the locus for Cuban culture, whereby cultural history becomes the trope for exploring not only the city but also Cuban national identity. Farber revisits his own and others’ interpretations of the origins of the Cuban Revolution.

  11. Radiation studies in Lens culinaris

    International Nuclear Information System (INIS)

    Sinha, S.S.N.

    1977-01-01

    Estimation of chromosomal aberrations in flowers of Lens culinaris according to their sequence of development in the plants at 4, 8 and 12 Kr in the M 1 generation, showed that the later formed flowers had smaller percentages of cells with aberrations than those developed earlier. It is suggested that this may be the result of competition between more damaged and less damaged cells during the development of the shoot. There is consequently a decrease of sterility in successive flowers. The numbers of karyotypes taking part in the formation of lower and uppermost flowers were estimated cytologically at 4, 8 and 12 Kr. It was found that more karyotypes were involved in the formation of the lower flowers than in the upper ones. It appeared that at lower doses larger numbers of karyotypes were taking part in the formation of the chimaera than at higher doses. (auth.)

  12. Microbial contamination of contact lens storage cases and domestic tap water of contact lens wearers.

    Science.gov (United States)

    Üstüntürk, Miray; Zeybek, Zuhal

    2012-11-01

    Contact lenses have been widely used as an alternative to spectacles both in developed and developing countries. However, under certain circumstances, adverse responses can occur during contact lens wear and several microorganisms--including bacteria, fungi, and free living amoebae--can cause several eye infections in wearers. Extended wear of contact lenses is the major risk factor of eye infections such as microbial keratitis, besides contaminated contact lens storage case, contaminated lens care solutions, and inaccurate contact lens handling. In this study, we collected contact lens storage case and domestic tap water samples from 50 asymptomatic contact lens wearers. We determined that total aerobic mesophilic bacteria were isolated in 45 (90 %), Gram negative rod bacteria were isolated in 20 (40 %), Pseudomonas spp. were isolated in 2 (4 %) and fungi were isolated in 18 (36 %) out of 50 contact lens storage cases. Free living amoebae were not detected in investigated contact lens storage cases. At the same time, out of 50, total aerobic mesophilic bacteria were isolated in 34 (68 %), fungi were isolated in 15 (30 %) and free living amoebae were isolated in 15 (30 %) domestic tap water samples. No Gram-negative rod bacteria and Pseudomonas spp. were detected in investigated water samples. Two contact lens case samples and two tap water samples were excluded from the analysis for Pseudomonas spp. for technical reasons. According to our findings, inadequate contact lens maintenance during lens wear may result in the contamination of contact lens storage cases. This situation can lead to severe eye infections in contact lens wearers over time.

  13. 21 CFR 520.1920 - Prochlorperazine, isopropamide sustained release capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Prochlorperazine, isopropamide sustained release capsules. 520.1920 Section 520.1920 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... dogs in which gastrointestinal disturbances are associated with emotional stress. (2)(i) Capsules...

  14. The development of the nasal capsule of the silver carp ...

    African Journals Online (AJOL)

    The development of the nasal capsule, including the procartilaginous as well as some mesenchymatous developmental stages, is described in the Chinese silver carp, Hypophthalmichthys molitrix (Val.). In the nasal capsule a primitive feature, namely the presence of a complete paraphysial bridge was observed.

  15. The development of the nasal capsule of the silver carp ...

    African Journals Online (AJOL)

    The development of the nasal capsule, including the procartilaginous as well as some mesenchymatous developmental stages, is described in the chinese silver carp,. Hypophthalmichthys molitrix (VaL). In the nasal capsule a primitive feature, namely the presence of a complete paraphysial bridge was observed.

  16. Evidence for an intact polysaccharide capsule in Bordetella pertussis.

    Science.gov (United States)

    Neo, YiLin; Li, Rui; Howe, Josephine; Hoo, Regina; Pant, Aakanksha; Ho, SiYing; Alonso, Sylvie

    2010-03-01

    Polysaccharide capsules contribute to the pathogenesis of many bacteria species by providing resistance against various defense mechanisms. The production of a capsule in Bordetella pertussis, the etiologic agent of whooping cough, has remained controversial; earlier studies reported this pathogen as a capsulated microorganism whereas the recent B. pertussis genome analysis revealed the presence of a truncated capsule locus. In this work, using transmission electron microscopy and immunostaining approaches, we provide a formal evidence for the presence of an intact microcapsule produced at the surface of both laboratory strain and clinical isolates of B. pertussis. In agreement with previous studies, we found that the capsule is optimally produced in avirulent phase. Unexpectedly, the presence of the capsule was also detected at the surface of virulent B. pertussis bacteria. Consistently, a substantial transcriptional activity of the capsule operon was detected in virulent phase, suggesting that the capsular polysaccharide may play a role during pertussis pathogenesis. In vitro assays indicated that the presence of the capsule does not affect B. pertussis adherence to mammalian cells and does not further protect the bacterium from phagocytosis, complement-mediated killing or antimicrobial peptide attack. Copyright 2009. Published by Elsevier SAS.

  17. Temporary presence of myofibroblasts in human elbow capsule after trauma

    NARCIS (Netherlands)

    Doornberg, Job N.; Bosse, Tjalling; Cohen, Mark S.; Jupiter, Jesse B.; Ring, David; Kloen, Peter

    2014-01-01

    Elbow stiffness is a common complication after elbow trauma. The elbow capsule is often thickened, fibrotic, and contracted at the time of surgical release. The limited studies available suggest that the capsule is contracted because of fibroblast-to-myofibroblast differentiation. We hypothesize

  18. Diamagnetically stabilized levitation control of an intraluminal magnetic capsule

    International Nuclear Information System (INIS)

    Lam, Michael; Mintchev, Martin

    2009-01-01

    Controlled navigation promotes full utilization of capsule endoscopy for reliable real-time diagnosis in the gastrointestinal (GI) tract, but intermittent natural peristalsis can disturb the navigational control, destabilize the capsule and take it out of levitation. The focus of the present work was to develop an economical and effective real-time magnetic capsule-guiding system that can operate in the presence of naturally existing peristalsis while retaining navigational control. A real-size magnetic navigation system that can handle peristaltic forces of up to 1.5 N was designed utilizing the computer-aided design (CAD) system Maxwell 3D (Ansoft, Pittsburg, PA) and was verified using a small-size physical experimental setup. The proposed system contains a pair of 50 cm diameter, 10 000-turn copper electromagnets with a 10 cm × 10 cm ferrous core driven by currents of up to 300 A and can successfully maintain position control over the levitating capsule during peristalsis. The addition of bismuth diamagnetic casing for stabilizing the levitating capsule was also studied. A modeled magnetic field around the diamagnetically cased permanent magnet was shown to be redistributed aligning its interaction with the external electromagnets, thus stabilizing the levitating capsule. In summary, a custom-designed diamagnetically facilitated capsule navigation system can successfully steer an intraluminal magnet-carrying capsule

  19. Material properties of the human posterior knee capsule

    NARCIS (Netherlands)

    Rachmat, H. H.; Janssen, D.; Verkerke, G. J.; Diercks, R. L.; Verdonschot, N.

    2015-01-01

    BACKGROUND: There is considerable interest to develop accurate subject-specific biomechanical models of the knee. Most of the existing models currently do not include a representation of the posterior knee capsule. In order to incorporate the posterior capsule in knee models, data is needed on its

  20. Material properties of the human posterior knee capsule

    NARCIS (Netherlands)

    Rachmat, H.H.; Janssen, D.W.; van Tienen, T.; Diercks, R.L.; Verkerke, Gijsbertus Jacob; Verdonschot, Nicolaas Jacobus Joseph; Fernandes, Paulo; Folgado, Joao; Silva, Miguel

    2012-01-01

    BACKGROUND: There is considerable interest to develop accurate subject-specific biomechanical models of the knee. Most of the existing models currently do not include a representation of the posterior knee capsule. In order to incorporate the posterior capsule in knee models, data is needed on its

  1. Iodometric determination of ampicillin in proprietary capsules | Ejele ...

    African Journals Online (AJOL)

    The concentration of ampicillin in ampicillin capsule preparations purchased in Owerri main market, Imo State of Nigeria, was determined using the iodometric titration method. The results showed that the ampicillin concentrations in the capsules contained between 250 and 260 mg/cap of ampicillin trihydrate. Statistical ...

  2. Langmuir and Langmuir–Blodgett films of capsules of haemoglobin ...

    Indian Academy of Sciences (India)

    Haemoglobin; capsules; Langmuir–Blodgett films; pH; multi-walled capsules; isoelectric point. 1. Introduction. Drug delivery and storage of formulations in pharma- ceutical applications require microencapsulation tech- niques. Many different methods have been used to develop encapsulation techniques for the purpose of.

  3. Pharmacokinetic Study of a Capsule-based Chronomodulated Drug ...

    African Journals Online (AJOL)

    Purpose: To develop and determine the in vivo performance of a capsule-based pulsatile drug delivery system containing salbutamol sulphate. Methods: A controlled pulsatile release of drug after a programmed 4 h lag period was achieved from cross-linked gelatin capsule shells containing salbutamol pellets, and sealed ...

  4. Clinical effect of Resina Draconis capsules on primary dysmenorrhoea

    African Journals Online (AJOL)

    Clinical effect of Resina Draconis capsules on primary dysmenorrhoea. Li Sun, Jia Wang. Abstract. Purpose: To examine the effectiveness of Resina Draconis capsules in the treatment of primary dysmenorrhoea. Methods: In total, 324 patients with primary dysmenorrhoea were randomly allocated to three groups based on ...

  5. Agile patency system eliminates risk of capsule retention in patients with known intestinal strictures who undergo capsule endoscopy.

    Science.gov (United States)

    Herrerias, Juan M; Leighton, Jonathan A; Costamagna, Guido; Infantolino, Anthony; Eliakim, Rami; Fischer, Doron; Rubin, David T; Manten, Howard D; Scapa, Eitan; Morgan, Douglas R; Bergwerk, Ari J; Koslowsky, Binyamin; Adler, Samuel N

    2008-05-01

    Capsule endoscopy (CE) of the small bowel has become a standard diagnostic tool, but there have been concerns regarding the risk of capsule retention in certain high-risk groups. The Agile patency system, an ingestible and dissolvable capsule with an external scanner, was developed to allow physicians to perform CE with greater confidence that the capsule will be safely excreted in patients at risk for capsule retention. Our purpose was to assess the ability of the device to help physicians identify which patients with known strictures may safely undergo CE. Patients with known strictures ingested the new patency capsule and underwent periodic scanning until it was excreted. The intestinal tract was considered to be sufficiently patent if the capsule was excreted intact or if the capsule was not detected by the scanner at 30 hours after ingestion. If patency was established, then standard CE was performed. International multicenter study. A total of 106 patients with known strictures. Agile patency system. Performance and safety of Agile patency system. A total of 106 patients ingested the patency capsule. Fifty-nine (56%) excreted it intact and subsequently underwent CE. There were no cases of capsule retention. Significant findings on CE were found in 24 (41%). There were 3 severe adverse events. These results suggest that the Agile patency system is a useful tool for physicians to use before CE in patients with strictures to avoid retention. This group of patients may have a high yield of clinically significant findings at CE. This capsule may determine whether patients who have a contraindication to CE may safely undergo CE and obtain useful diagnostic information.

  6. Unilateral anterior uveitis complicating zoledronic acid therapy in breast cancer

    Directory of Open Access Journals (Sweden)

    El Saghir Nagi S

    2005-12-01

    Full Text Available Abstract Background Zoledronic acid is very widely used in patients with metastatic bone disease and osteoporosis. Only one case of bilateral uveitis was recently reported related to its use. Case presentation We report the first case of severe unilateral anterior uveitis in a patient with breast cancer and an intraocular lens. Following zoledronic acid infusion, the patient developed severe and dramatic right eye pain with decreased visual acuity within 24 hours and was found to have a fibrinous anterior uveitis of moderate severity The patient was treated with topical prednisone and atropine eyedrops and recovered slowly over several months. Conclusion Internists, oncologists, endocrinologists, and ophtalmologists should be aware of uveitis as a possible complication of zoledronic acid therapy. Patients should be instructed to report immediately to their physicians and treatment with topical prednisone and atropine eyedrops should be instituted immediately at the onset of symptoms. This report documents anterior uveitis as a complication of zoledronic acid therapy. This reaction could be an idiosyncratic one but further research may shed more light on the etiology.

  7. Recurrent iridocyclitis due to cotton fiber in anterior chamber.

    Science.gov (United States)

    Joshi, Rajesh S

    2016-01-01

    Cotton is commonly used during ophthalmic surgical procedure. Cotton fibers may get attracted to the instruments due to electrostatic forces and become adhered to the surface. With the introduction of these instruments during the surgical procedure cotton fiber may get entry into the eye. In the literature they have been infrequently reported due to insignificant effect on the ocular structures. We present a case of recurrent iridocyclitis due to cotton fiber in the anterior chamber. Patient was relived of his symptoms after removal. A 78-year-old male presented with pain, redness and blurring of right eye vision since last six months. The patient had undergone phacoemulsification with implantation of hydrophilic intraocular lens (IOL) six years earlier. Postoperative follow up was uneventful from his records till last 6 months. Slit-lamp examination revealed a cotton fiber in the anterior chamber touching the endothelium. Keratic precipitates were seen on the endothelium. Removal of the cotton fiber resulted in subsidence of inflammation. We recommend use of plastic eye and trolley drapes, lint free instrument wipes and use of needle cap to support the globe during creation of side port while performing phacoemulsification instead of cotton buds to avoid entry of cotton fiber into the anterior chamber. © NEPjOPH.

  8. Analysis of Fission Products on the AGR-1 Capsule Components

    Energy Technology Data Exchange (ETDEWEB)

    Paul A. Demkowicz; Jason M. Harp; Philip L. Winston; Scott A. Ploger

    2013-03-01

    The components of the AGR-1 irradiation capsules were analyzed to determine the retained inventory of fission products in order to determine the extent of in-pile fission product release from the fuel compacts. This includes analysis of (i) the metal capsule components, (ii) the graphite fuel holders, (iii) the graphite spacers, and (iv) the gas exit lines. The fission products most prevalent in the components were Ag-110m, Cs 134, Cs 137, Eu-154, and Sr 90, and the most common location was the metal capsule components and the graphite fuel holders. Gamma scanning of the graphite fuel holders was also performed to determine spatial distribution of Ag-110m and radiocesium. Silver was released from the fuel components in significant fractions. The total Ag-110m inventory found in the capsules ranged from 1.2×10 2 (Capsule 3) to 3.8×10 1 (Capsule 6). Ag-110m was not distributed evenly in the graphite fuel holders, but tended to concentrate at the axial ends of the graphite holders in Capsules 1 and 6 (located at the top and bottom of the test train) and near the axial center in Capsules 2, 3, and 5 (in the center of the test train). The Ag-110m further tended to be concentrated around fuel stacks 1 and 3, the two stacks facing the ATR reactor core and location of higher burnup, neutron fluence, and temperatures compared with Stack 2. Detailed correlation of silver release with fuel type and irradiation temperatures is problematic at the capsule level due to the large range of temperatures experienced by individual fuel compacts in each capsule. A comprehensive Ag 110m mass balance for the capsules was performed using measured inventories of individual compacts and the inventory on the capsule components. For most capsules, the mass balance was within 11% of the predicted inventory. The Ag-110m release from individual compacts often exhibited a very large range within a particular capsule.

  9. Adsorption and desorption of phosphorus in ceramic capsules

    International Nuclear Information System (INIS)

    Almeida, J.R.F. de.

    1983-01-01

    Experiments were carried out in order to analyse the capacity of adsorving P from water using ceramic capsules with 32P, in the presence and absence of water flow through the capsule. Also studied was the desorption of 32 P from the capsule in water, with and without water flow. The desorption of residual 32 P was analysed by isotopic exchange with 31 P, also with and without water flow. It was observed that, in the presence of a flow, the capsule retained 32 P from the solution, which was weakly desorbed by water but was isotopically exchanged with 31 P. In the absence of a flow, the capsule was not an efficient P adsorber. (Author) [pt

  10. [Wireless capsule endoscopy: basic principles and clinical utility].

    Science.gov (United States)

    González-Suárez, Begoña; Galter, Sara; Balanzó, Joaquín

    2007-06-01

    Wireless capsule endoscopy (PillCam) represents a major advance in the study of small bowel disease since this procedure allows images of hitherto unreachable areas to be obtained. Approved for use by the Food and Drug Administration in August 2000, capsule endoscopy is currently a first line procedure in the study of small bowel disease. This technique consists of a non-reusable swallowable capsule (length 26 x 11 mm) that acquires video images while moving through the gastrointestinal tract propelled by natural peristalsis. The main indications of capsule endoscopy are evaluation of obscure gastrointestinal bleeding, chronic anemia, and inflammatory bowel disease. Contraindications are swallowing disorders and known or suspected small bowel strictures of any etiology. Consequently, small bowel follow through is useful prior to capsule endoscopy when these lesions are suspected.

  11. Multi-modal imaging of adhesive capsulitis of the shoulder.

    Science.gov (United States)

    Zappia, Marcello; Di Pietto, Francesco; Aliprandi, Alberto; Pozza, Simona; De Petro, Paola; Muda, Alessandro; Sconfienza, Luca Maria

    2016-06-01

    Adhesive capsulitis of the shoulder is a clinical condition characterized by progressive limitation of active and passive mobility of the glenohumeral joint, generally associated with high levels of pain. Although the diagnosis of adhesive capsulitis is based mainly on clinical examination, different imaging modalities including arthrography, ultrasound, magnetic resonance, and magnetic resonance arthrography may help to confirm the diagnosis, detecting a number of findings such as capsular and coracohumeral ligament thickening, poor capsular distension, extracapsular contrast leakage, and synovial hypertrophy and scar tissue formation at the rotator interval. Ultrasound can also be used to guide intra- and periarticular procedures for treating patients with adhesive capsulitis. • Diagnosis of adhesive capsulitis is mainly based on clinical findings. • Imaging may be used to exclude articular or rotator cuff pathology. • Thickening of coracohumeral and inferior glenohumeral ligaments are common findings. • Rotator interval fat pad obliteration has 100 % specificity for adhesive capsulitis. • Ultrasound can be used to guide intra- and periarticular treatments.

  12. Intra-articular injection of hyaluronate versus corticosteroid in adhesive capsulitis.

    Science.gov (United States)

    Lim, Tae Kang; Koh, Kyoung Hwan; Shon, Min Soo; Lee, Seung Won; Park, Young Eun; Yoo, Jae Chul

    2014-10-01

    The goal of this study was to prospectively compare the early clinical results of intra-articular injection of hyaluronate or corticosteroid in patients with idiopathic adhesive capsulitis. The authors' hypothesis was that there would be no difference between groups. Sixty-eight patients with idiopathic adhesive capsulitis were equally randomized to receive either corticosteroid or hyaluronate injection. All patients underwent standard physical examination and magnetic resonance imaging. Intra-articular injection was performed through an anterior approach by the same orthopedic surgeon without image guidance. Patients were followed up 2 and 12 weeks after completion of the injection. The primary outcome was the Constant score at week 12. Secondary outcomes included the visual analog scale (VAS) pain score, the American Shoulder and Elbow Surgeons (ASES) score, and range of motion at each time point. No significant differences were noted in preoperative demographic features or baseline shoulder function between groups. After treatment, no significant differences were noted in early clinical outcomes (at weeks 2 and 12) with VAS, ASES, and Constant scores between groups (all P>.05). Evaluation of range of motion showed no difference in forward elevation or external rotation at each time point. Internal rotation was significantly lower at week 2 in the hyaluronate group compared with the corticosteroid group (P=.015). Internal rotation improved at week 12, with no significant difference between groups. Patients treated with intra-articular injection of hyaluronate and corticosteroid for idiopathic adhesive capsulitis showed significant improvement in early clinical scores and range of motion without significant differences between groups. Copyright 2014, SLACK Incorporated.

  13. Pars plana vitrectomy with posterior iris claw implantation for posteriorly dislocated nucleus and intraocular lens

    Directory of Open Access Journals (Sweden)

    Kishor B Patil

    2011-01-01

    Full Text Available We evaluated the safety and efficacy of pars plana vitrectomy (PPV with primary posterior iris claw intraocular lens (IOL implantation in cases of posterior dislocation of nucleus and IOL without capsular support. This was a retrospective interventional case series. Fifteen eyes underwent PPV with primary posterior iris claw IOL implantation performed by a single vitreoretinal surgeon. The main outcome measures were changes in best corrected visual acuity and anterior and posterior segment complications. A total of 15 eyes were included in this study. Eight had nucleus drop, three had IOL drop during cataract surgery and four had traumatic posterior dislocation of lens. The final postoperative best corrected visual acuity was 20/60 or better in 11 patients. This procedure is a viable option in achieving good functional visual acuity in eyes without capsular support.

  14. Study of the structure of buffalo's eye lens and scleroretinal rim in Tabriz by ultrasonography

    Directory of Open Access Journals (Sweden)

    GH Assadnassab

    2011-05-01

    Full Text Available In this study, ultrasonographic condition of lens and posterior wall of buffalo's eye in Tabriz area were investigated due to their important role in vision and also measurements were made in anterior-posterior axial B-mode display methods. The ultrasonographic images were similar to the images obtained from other particularly the cow. Total thickness of the lens was 1.133 ± 0.052 cm with the thickness being 1.135 ± 0.052 cm in the right eye and 1.132 ± 0.053 cm in the left eye. Thickness of the posterior wall of the right and left eyes were 1.677 ± 0.042 mm and 1.672 ± 0.041 mm respectively with the total thickness of the posterior wall measuring 1.674 ± 0.040 mm. There was no significant difference between the left and right eyes regarding these parameters.

  15. Integrated Diagnostic Analysis of ICF Capsule Performance

    Science.gov (United States)

    Cerjan, Charles

    2012-10-01

    An understanding of the dynamics of imploding Inertial Confinement Fusion (ICF) capsules is crucial to achieve high convergence and gain. The relative roles of laser irradiation, hohlraum drive, and capsule response are intertwined and will be difficult to disentangle unless appropriate diagnostic probes are fielded and their results correlated. In the case of capsule implosions, several currently deployed diagnostics provide important information about the size and shape of the developing hot spot through x-ray self-emission, neutron production and average ion temperature by neutron time-of-flight signals, shell material mix into the hot spot by high-resolution x-ray spectra, and remaining mass during convergent ablation by x-ray backlighting. Obtaining a physically consistent picture of the implosion dynamics requires an integration of these disparate experimental data. This talk describes a three-dimensional model that attempts this integration. Assuming pressure equilibrium at peak compression and invoking simple radiative and equation-of-state relations, the pressure, density and electron temperature are obtained by optimized fitting of the experimental output to simple, global functional forms. The fitting procedure is sufficiently flexible to incorporate typical observational data such as x-ray self-emission, neutron time-of-flight signals, neutron yield, high-resolution x-ray spectra and radiographic images. Once consistency is obtained, many important secondary quantities can be derived such as the fuel areal density, high energy x-ray emission, neutron images, and nuclear activation. This approach has been validated by comparison with radiation-hydrodynamic simulations, producing semi-quantitative agreement and is now routinely used to characterize cryogenic implosion experiments. This talk will provide an overview of the implementation of the model and describe its application to recent experimental data.[4pt] In addition to my collaborators Paul

  16. Conventional MRI Finding in a Case of Adhesive Shoulder Capsulitis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hak Hoon [Yeosu Hanyeoexpo Hospital, Yeosu (Korea, Republic of); Back, Chang Hee [Yeosu Baek Hospital, Yeosu (Korea, Republic of)

    2010-02-15

    To evaluate the conventional magnetic resonance image findings in patients with adhesive shoulder capsulitis. The preoperative MR images of 76 patients with adhesive shoulder capsulitis that was also treated by arthroscopic capsule release. In contrast to the MR images of 25 control patients without adhesive shoulder capsulitis, the thickness and area of hyposignal intensity around the coracohumeral ligament (CHL), subcoracoidal fat, capsular thickness of the rotator interval, capsular thickness, and height of the axillary recess were measured. The existence of fluid in the axillary recess was also verified. Patients with adhesive capsulitis showed a significant increase in the thickness (average 10.57 mm vs. 5.88 mm, T=8.289, p<0.001), area (average 3.49 point vs. 0.96 point Z=7.775, p< 0.001) of hyposignal intensity around CHL, and a thickened joint capsule in the rotator interval (average 5.93 mm vs. 2.15 mm, Z=6.472, p< 0.001). The thickness of the hyposignal intensity around the CHL is about 10 mm or more and has a specificity of 96%, a sensitivity of about 55% in the area of hyposignal intensity from around the CHL, Seventy-five percent or more of cases, showed a 100%, 95%, complete obliteration of the subcoracoidal fat that was 96%, and a 50% thickness of the capsule. A rotator interval of 6mm or more had a 96%, 50% for the diagnosis of adhesive capsulitis of the shoulder. The capsular thickness and maximal height of axillary recess and the presence of fluid in the axillary recess was not significant in patients with adhesive shoulder capsulitis. Thickening of the hyposignal intensity around the CHL, subcoracoidal fat obliteration, and capsular thickening at the rotator interval, are characteristic MRI findings in adhesive shoulder capsulitis

  17. Anterior segment indocyanine green angiography in anterior scleritis and episcleritis.

    Science.gov (United States)

    Guex-Crosier, Yan; Durig, Jacques

    2003-09-01

    To evaluate the pattern of anterior segment indocyanine green (ICG) angiography in episcleritis and scleritis. Prospective comparative (paired-eye) observational case series. Twenty subjects presenting clinical diseases compatible with episcleritis or scleritis. Anterior segment ICG angiography was performed according to a standard protocol in subjects presenting either episcleritis or scleritis. Photographs of the anterior segment were taken in the early phase (up to 3 minutes after dye injection), intermediate phase (10-12 minutes) and late phase (30-45 minutes). The inflamed zones were compared with the same regions of the controlateral eye. The amount of protein ICG exudation was scored by a masked observer as follows: zero for no exudation, one for slight exudation, two for moderate exudation, and three for severe exudation. Evaluation of dye leakage, which reflects protein exudation, with anterior segment ICG angiography in episcleritis and scleritis. Twenty subjects with a mean age of 43 +/- 15 years (7 male, 13 female) were enrolled in the study. Thirteen subjects had anterior scleritis (7 nodular, 5 diffuse, and 1 scleromalacia perforans), and 7 subjects had episcleritis. Only 1 out of 7 subjects with episcleritis showed a slight ICG leakage (a score of one), whereas all subjects with scleritis had ICG leakage scores of one or more (P = 0.0005, Fisher exact test). ICG angiography of the anterior segment of the eye is a good clinical test to differentiate episcleritis from scleritis.

  18. Comparison of anterior segment optical coherence tomography angiography and fluorescein angiography for iris vasculature analysis.

    Science.gov (United States)

    Zett, Claudio; Stina, Deborah M Rosa; Kato, Renata Tiemi; Novais, Eduardo Amorim; Allemann, Norma

    2018-04-01

    The aim of this study is to perform imaging of irises of different colors using spectral domain anterior segment optical coherence tomography angiography (AS-OCTA) and iris fluorescein angiography (IFA) and compare their effectiveness in examining iris vasculature. This is a cross-sectional observational clinical study. Patients with no vascular iris alterations and different pigmentation levels were recruited. Participants were imaged using OCTA adapted with an anterior segment lens and IFA with a confocal scanning laser ophthalmoscope (cSLO) adapted with an anterior segment lens. AS-OCTA and IFA images were then compared. Two blinded readers classified iris pigmentation and compared the percentage of visible vessels between OCTA and IFA images. Twenty eyes of 10 patients with different degrees of iris pigmentation were imaged using AS-OCTA and IFA. Significantly more visible iris vessels were observed using OCTA than using FA (W = 5.22; p Iris pigmentation was negatively correlated to the percentage of visible vessels in both imaging methods (OCTA, rho = - 0.73, p iris vasculature. In both AS-OCTA and IFA, iris pigmentation caused vasculature imaging blockage, but AS-OCTA provided more detailed iris vasculature images than IFA. Additional studies including different iris pathologies are needed to determine the most optimal scanning parameters in OCTA of the anterior segment.

  19. Combined surgical management of capsular and iris deficiency with glued intraocular lens technique.

    Science.gov (United States)

    Kumar, Dhivya Ashok; Agarwal, Amar; Jacob, Soosan; Lamba, Mandeep; Packialakshmi, Sathiya; Meduri, Alessandro

    2013-05-01

    To determine the outcome after glued aniridia intraocular lens (IOL) and glued IOL with iridoplasty in eyes with combined lens capsular and iris deficiency. Twenty-seven eyes of 25 patients (6 had congenital aniridia with subluxated cataract and 19 had acquired lens/iris defects) were included. Glued IOL with aniridia IOL (Intra Ocular Care, Gujarat, India) was performed in eyes with total aniridia and iridoplasty with glued IOL with a three-piece foldable IOL (Sofport; Bausch & Lomb, Rochester, NY) was performed in eyes with partial aniridia. The postoperative outcomes were analyzed at follow-up examination (range: 6 to 48 months). Eleven eyes underwent glued aniridia IOL and 16 eyes underwent glued IOL with iridoplasty. There was significant improvement in (spectacle) corrected distance visual acuity (CDVA) (P = .002). Postoperatively, pigment dispersion on the IOL (n = 1) and raised intraocular pressure was seen in the glued aniridia IOL group and chronic uveitis (n = 1), cystoid macular edema (n = 1), and hyphema (n = 1) in the glued IOL with iridoplasty group. The CDVA remained unchanged in 14 eyes (51.8%) and improved in 13 eyes (48.1%). There was a difference in postoperative CDVA (P = .001) between eyes with glued aniridia IOL and glued IOL with iridoplasty. There was no IOL decentration, retinal detachment, corneal decompensation, or endophthalmitis. There was reduction in glare and photophobia. Both glued aniridia IOL and glued IOL/iridoplasty showed good functional and anatomical results with fewer complications in eyes with lens capsule and iris deficiency. However, long-term follow-up is required.[J Refract Surg. 2013;29(5):342-347.]. Copyright 2013, SLACK Incorporated.

  20. Electromagnetic Control System for Capsule Navigation: Novel Concept for Magnetic Capsule Maneuvering and Preliminary Study.

    Science.gov (United States)

    Lucarini, Gioia; Mura, Marco; Ciuti, Gastone; Rizzo, Rocco; Menciassi, Arianna

    The gastrointestinal tract is home of some of the most deadly human diseases. The main problems are related to the difficulty of accessing it for diagnosis or intervention and concomitant patient discomfort. The flexible endoscopy technique has established itself in medical practice due to its high diagnostic accuracy and reliability; however, several technical limitations still remain and the procedure is poorly tolerated by patients. The use of magnetic fields to control and steer endoscopic capsules is increasing in minimally invasive procedures. In fact, magnetic coupling is one of the few physical phenomena capable of transmitting motion beyond a physical barrier, allowing for the compact design of the device itself. In this framework, the authors present the preliminary design and assessment of a magnetic coupling for magnetic endoscopic capsules considering an electromagnetic approach. In particular, a novel toroidal electromagnet is proposed as the control and driving system. The system concept, design, and preliminary results are reported.

  1. Clinical features of secondary glaucoma caused by lens suspensory ligament laxity or occult subluxation

    Directory of Open Access Journals (Sweden)

    Yi Ma

    2018-04-01

    Full Text Available AIM: To investigate the clinical characteristics of secondary glaucoma caused by lens suspensory ligament laxity or occult subluxation, and to analyze the influence of operation on visual acuity and intraocular pressure(IOP. METHODS: Totally 38 cases(38 eyesof the secondary glaucoma caused by lens suspensory ligament laxity or occult subluxation in ophthalmology department of our hospital from December 2014 to December 2016 were enrolled and their medical records were analyzed retrospectively to observe the clinical characteristics of glaucoma. Preoperative mydriasis was carried out and surgical methods were chosen according to the lenses location and extent of suspensory ligament. Preoperative and postoperative anterior chamber depth, corneal endothelial cell density, IOP, visual field, visual acuity and complications were analyzed. RESULTS: The average intraocular pressure was 18.17±1.43mmHg at postoperatively 10d, which was significantly lower than 38.77±2.45mmHg before operation, the difference had statistical significance(PP>0.05. The postoperative anterior chamber depth was 2.45±0.44mm, which was significantly higher than 1.23±0.35mm before operation, the difference had statistical significance(P2 and decreased significantly, compared with 1735.32±340.32/mm2 before operation, the difference had statistical significance(PCONCLUSION: Clinical symptoms and signs of secondary glaucoma in patients with lens suspensory ligament laxity or occult subluxation are more complex, which needs to be distinguished with other types of glaucoma in clinical treatment, and its surgical methods shall be chosen according to different suspensory ligament site and lens subluxation scope.

  2. Photophysics Applied to Cavitands and Capsules.

    Science.gov (United States)

    Berryman, Orion B; Dube, Henry; Rebek, Julius

    2011-07-01

    The use of light as a stimulus to control functional materials or nano-devices is appealing as it provides convenient control of triggering events where and when they are desired without introducing extra components to the system. Many photophysical and photochemical processes are extremely fast, giving rise to nearly instantaneous onset of events. However, these fast processes can be challenging to engineer into chemical systems. Supramolecular chemistry offers a convenient way to study and control photoprocesses. Given the reversible and self-programmed nature of modern host-guest systems, a modular approach can be considered in which different photoprocesses are coupled to obtain complex functions that emerge and are controlled solely by light inputs. In this review, we highlight recent examples of photoswitching and photophysics applied in the context of supramolecular host-guest systems, with a particular emphasis on resorcinarene based cavitands and hydrogen bonded capsules.

  3. Multilevel wireless capsule endoscopy video segmentation

    Science.gov (United States)

    Hwang, Sae; Celebi, M. Emre

    2010-03-01

    Wireless Capsule Endoscopy (WCE) is a relatively new technology (FDA approved in 2002) allowing doctors to view most of the small intestine. WCE transmits more than 50,000 video frames per examination and the visual inspection of the resulting video is a highly time-consuming task even for the experienced gastroenterologist. Typically, a medical clinician spends one or two hours to analyze a WCE video. To reduce the assessment time, it is critical to develop a technique to automatically discriminate digestive organs and shots each of which consists of the same or similar shots. In this paper a multi-level WCE video segmentation methodology is presented to reduce the examination time.

  4. Anterior segment sparing to reduce charged particle radiotherapy complications in uveal melanoma

    International Nuclear Information System (INIS)

    Daftari, Inder K.; Char, Devron H.; Verhey, Lynn J.; Castro, Joseph R.; Petti, Paula L.; Meecham, William J.; Kroll, Stewart; Blakely, Eleanor A.

    1997-01-01

    Purpose: The purpose of this investigation is to delineate the risk factors in the development of neovascular glaucoma (NVG) after helium-ion irradiation of uveal melanoma patients and to propose treatment technique that may reduce this risk. Methods and Materials: 347 uveal melanoma patients were treated with helium-ions using a single-port treatment technique. Using univariate and multivariate statistics, the NVG complication rate was analyzed according to the percent of anterior chamber in the radiation field, tumor size, tumor location, sex, age, dose, and other risk factors. Several University of California San Francisco-Lawrence Berkeley National Laboratory (LBNL) patients in each size category (medium, large, and extralarge) were retrospectively replanned using two ports instead of a single port. By using appropriate polar and azimuthal gaze angles or by treating patients with two ports, the maximum dose to the anterior segment of the eye can often be reduced. Although a larger volume of anterior chamber may receive a lower dose by using two ports than a single port treatment. We hypothesize that this could reduce the level of complications that result from the irradiation of the anterior chamber of the eye. Dose-volume histograms were calculated for the lens, and compared for the single and two-port techniques. Results: NVG developed in 121 (35%) patients. The risk of NVG peaked between 1 and 2.5 years posttreatment. By univariate and multivariate analysis, the percent of lens in the field was strongly correlated with the development of NVG. Other contributing factors were tumor height, history of diabetes, and vitreous hemorrhage. Dose-volume histogram analysis of single-port vs. two-port techniques demonstrate that for some patients in the medium and large category tumor groups, a significant decrease in dose to the structures in the anterior segment of the eye could have been achieved with the use of two ports. Conclusion: The development of NVG after

  5. Contact lens compliance among a group of young, university-based lens users in South India.

    Science.gov (United States)

    Noushad, Babu; Saoji, Yeshwant; Bhakat, Premjit; Thomas, Jyothi

    2012-01-01

    To investigate the rate of compliance with the soft contact lens care and maintenance procedures with a focus on contact lens wearing habits, cleaning and disinfecting procedures, and maintenance of lens care accessories in a group of young, university-based contact lens wearers Two hundred and sixteen young soft contact lens wearers with an age range of 18-22 years were selected conveniently from the student population of Manipal University, Manipal, India. After receiving informed consent from the participants, their level of compliance with contact lenses was assessed using a questionnaire. The mean (±SD) age of the participants was 21.86±2.35 years. Out of 216 subjects, only 34% of the lens users were identified to be compliant with the least level of compliance observed in the maintenance of lens care accessories. Conventional users showed significantly (p=0.001) better level of compliance compared to disposable wearers and so did the users who acquired their lenses from clinicians (p=0.001) compared to over-the-counter lens receipt. The gender (p=0.496) and years of experience in contact lens use (p=0.142) did not show any statistically significant difference in the level of compliance. This study demonstrated that non-compliance with lens care procedures among a group of young, university-based soft contact lens wearers is common. The results indicated that all subjects had some degree of non-compliance and the least level of compliance observed in the care of lens accessories.

  6. Tear film physiology and contact lens wear. II. Contact lens-tear film interaction.

    Science.gov (United States)

    Holly, F J

    1981-04-01

    The successful fitting of contact lenses requires the practitioner to take into account many properties of the specific lens type used but the practitioner must also understand patient factors including tear properties, use of appropriate solutions, procedures for lens cleaning, and efficiency of blinking. Selection of appropriate patients, selection of lens type, proper fitting, good maintenance, and training and monitoring of patients increase the probability of achieving success.

  7. Capsule HRB-15B postirradiation examination report

    Energy Technology Data Exchange (ETDEWEB)

    Ketterer, J.W.; Bullock, R.E.

    1981-06-01

    Capsule HRB-15B design tested 184 thin graphite trays containing unbonded fuel particles to peak exposures of 6.6 x 10/sup 25/ n/m/sup 2/ (E > 29 fJ)/sub HTGR/ fast fluence, approx. 27% fissions per initial metal atom (FIMA) fissile burnup, and 6% FIMA fertile burnup at nominal time-averaged temperatures of 815 to 915/sup 0/C. The capsule tested a variety of low-enriched uranium (approx. 19.5% U-235) fissile particle types, including UC/sub 2/, UC/sub x/O/sub y/, UO/sub 2/, zirconium-buffered UO/sub 2/ (referred to in this report as UO/sub 2//sup *), and 1:1(Th,U)O/sub 2/ with both TRISO and silicon-BISO coatings. All fertile particles were ThO/sub 2/ with BISO, silicon-BISO, or TRISO coatings. The findings indicated that all TRISO particles retained virtually all of their fission product inventories, except small quantities of silver, at these irradiation temperatures, while some of the silicon-BISO particles released significant amounts of both silver and cesium. No kernel migration, pressure vessel, or outer pyrolytic carbon (OPyC) failures were observed in the fuel particles, which had total diameters of < 900 ..mu..m; however, the incidence of failed OPyC coatings was found to increase with particle size in the TRISO inert particles, which had diameters of 1000 to 1200 ..mu..m. UO/sub 2//sup */ particles exhibited no detrimental irradiation effects, but they contained pure carbon precipitates in the kernels after irradiation which were not observed in the undoped UO/sub 2/ particles. Postirradiation examination revealed no differences in the irradiation performance of three UC/sub x/O/sub y/ kernel types with varying oxygen/uranium ratios.

  8. Anterior Knee Pain (Chondromalacia Patellae).

    Science.gov (United States)

    Garrick, James G.

    1989-01-01

    This article presents a pragmatic approach to the definition, diagnosis, and management of anterior knee pain. Symptoms and treatment are described. Emphasis is on active involvement of the patient in the rehabilitation exercise program. (IAH)

  9. Anterior approach for knee arthrography

    International Nuclear Information System (INIS)

    Zurlo, J.V.; Towers, J.D.; Golla, S.

    2001-01-01

    Objective. To develop a new method of magnetic resonance arthrography (MRA) of the knee using an anterior approach analogous to the portals used for knee arthroscopy.Design. An anterior approach to the knee joint was devised mimicking anterior portals used for knee arthroscopy. Seven patients scheduled for routine knee MRA were placed in a decubitus position and under fluoroscopic guidance a needle was advanced from a position adjacent to the patellar tendon into the knee joint. After confirmation of the needle tip location, a dilute gadolinium solution was injected.Results and conclusion. All the arthrograms were technically successful. The anterior approach to knee MRA has greater technical ease than the traditional approach with little patient discomfort. (orig.)

  10. Toxic Anterior Segment Syndrome following a Triple Descemet’s Stripping Automated Endothelial Keratoplasty Procedure

    Directory of Open Access Journals (Sweden)

    Nir Sorkin

    2012-11-01

    Full Text Available Purpose: To present a unique case of a 58-year-old female with toxic anterior segment syndrome (TASS, following a triple procedure: Descemet’s stripping automated endothelial keratoplasty (DSAEK, phacoemulsification and posterior chamber intraocular lens implantation. Methods: The patient was treated with topical dexamethasone sodium phosphate 0.1% and topical atropine sulfate 1%. Due to a slow improvement in her clinical status, oral prednisone 1 mg/kg/day was added. Results: The anterior chamber reaction improved gradually, with tapering down of topical and oral treatment, until a complete resolution of the anterior chamber reaction was observed. Conclusions: Taking into account the estimated volume of DSAEK triple procedures performed worldwide, we would expect an annual incidence of several TASS cases, following triple DSAEK procedures. However, we were unable to find any such previous reports in the literature. This fact raises questions regarding the cause of reduced TASS incidence following triple DSAEK procedures.

  11. Placement of a crystalline lens and intraocular lens: Retinal image quality.

    Science.gov (United States)

    Siedlecki, Damian; Nowak, Jerzy; Zajac, Marek

    2006-01-01

    The influence of changes of both crystalline lens and intraocular lens (IOL) misalignment on the retinal image quality was investigated. The optical model of the eye used in investigations was the Liou-Brennan model, which is commonly considered as one of the most anatomically accurate. The original crystalline lens from this model was replaced with an IOL, made of rigid polymethylmethacrylate, in a way that recommend obligatory procedures. The modifications that were made both for crystalline lens and IOL were the longitudinal, the transversal, and the angular displacement.

  12. Development of Fresnel lens for improvement of rear visibility; Shikai kojo Fresnel lens no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, K.; Sanada, C.; Tsukino, M. [Nissan Motor Co. Ltd., Tokyo (Japan)

    1997-10-01

    Fresnel lenses have been widely used to increase the visual field around vehicles for drivers. However, internal reflection in these lenses has been an obstacle in producing dear images. This internal glow is generated by incident light from an unexpected direction reflecting on the non-lens surface or radiating from the non-lens surface of the Fresnel lens. The cause of internal glow has been made dear combining louver film with the lens. The newly developed technology removes obstacles in producing dear images by reducing internal glow. 7 figs.

  13. Night Vision Goggles Objectives Lens Focusing Methodology

    National Research Council Canada - National Science Library

    Pinkus, Alan; Task, H. L

    2000-01-01

    ...: interpupillary distance, tilt, eye relief, height, eyepiece and objective lens focus. Currently, aircrew use a Hoffman 20/20 test unit to pre-focus their NVG objective lenses at optical infinity before boarding their aircraft...

  14. Role of Aquaporin 0 in lens biomechanics

    Energy Technology Data Exchange (ETDEWEB)

    Sindhu Kumari, S.; Gupta, Neha [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Shiels, Alan [Washington University School of Medicine, St. Louis, MO (United States); FitzGerald, Paul G. [Cell Biology and Human Anatomy, School of Medicine, University of California, Davis, CA (United States); Menon, Anil G. [University of Cincinnati College of Medicine, Cincinnati, OH (United States); Mathias, Richard T. [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States)

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and

  15. Endoscopic endonasal anatomy and approaches to the anterior skull base: a neurosurgeon's viewpoint.

    Science.gov (United States)

    Abuzayed, Bashar; Tanriover, Necmettin; Gazioglu, Nurperi; Sanus, Galip Zihni; Ozlen, Fatma; Biceroglu, Huseyin; Kafadar, Ali Metin; Eraslan, Berna Senel; Akar, Ziya

    2010-03-01

    The objective of this study was to review the endoscopic anatomy of the anterior skull base, defining the pitfalls of endoscopic endonasal approaches to this region. Recently, these approaches are gaining popularity among neurosurgeons, and the details of the endoscopic anatomy and approaches are highlighted from the neurosurgeons' point of view, correlated with demonstrative cases. Twelve fresh adult cadavers were studied (n = 12). We used Karl Storz 0 and 30 degrees, 4 mm, 18- and 30-cm rod lens rigid endoscope in our dissections. After preparation of the cadaveric specimens, we approached the anterior skull base by the extended endoscopic endonasal approach. After resection of the superior portion of the nasal septum, bilateral middle and superior turbinates, and bilateral anterior and posterior ethmoidal cells, we could obtain full exposure of the anterior skull base. The distance between optic canal and the posterior ethmoidal artery ranged from 8 to 16 mm (mean, 11.08 mm), and the distance between posterior ethmoidal artery and the anterior ethmoidal artery ranged from 10 to 17 mm (mean, 13 mm). After resecting the anterior skull base bony structure and the dura between the 2 medial orbital walls, we could visualize the olfactory nerves, interhemispheric sulcus, and gyri recti. With dissecting the interhemispheric sulcus, we could expose the first (A1) and second (A2) segments of the anterior cerebral artery, anterior communicating artery, and Heubner arteries. This study showed that extended endoscopic endonasal approaches are sufficient in providing wide exposure of the bony structures, and the extradural and intradural components of the anterior skull base and the neighboring structures providing more controlled manipulation of pathologic lesions. These approaches need specific skill and learning curve to achieve more minimally invasive interventions and less postoperative complications.

  16. Contractual considerations in contact lens practice.

    Science.gov (United States)

    Classé, J G

    1986-03-01

    The use of forms in contact lens practice can save time, promote patient education, and reduce the opportunity for legal or economic disputes. The most commonly employed forms are those for contact lens fitting agreements, instructions for care and maintenance of lenses, prepaid service agreements, clinical investigations of investigatory lenses or solutions, and for extended wear patients. Sample forms are utilized for purposes of illustration.

  17. Evolution and the Calcite Eye Lens

    OpenAIRE

    Williams, Vernon L.

    2013-01-01

    Calcite is a uniaxial, birefringent crystal, which in its optically transparent form, has been used for animal eye lenses, the trilobite being one such animal. Because of the calcite birefringence there is a difficulty in using calcite as a lens. When the propagation direction of incoming light is not exactly on the c-axis, the mages blur. In this paper, calcite blurring is evaluated, and the non-blurring by a crystallin eye lens is compared to a calcite one.

  18. Acute lens-induced glaucomas: A review

    Directory of Open Access Journals (Sweden)

    Syed Shoeb Ahmad

    2017-02-01

    Full Text Available Lens-induced factors are important and common mechanisms causing acute elevation of intraocular pressure. While in most cases, the diagnosis and management are straight-forward, in others it is difficult and can lead to improper procedures, complications and poor visual outcomes. This review was done with the aim of studying the various types of lens-induced glaucomas, classifying them in an easy way to understand manner, their clinical features, current management and future possibilities.

  19. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma

    Directory of Open Access Journals (Sweden)

    Rui Wang

    2014-04-01

    Full Text Available AIM:To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL implantation.METHODS:Non-comparative retrospective observational case series. Participants:30 cases (30 eyes of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi''an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. Main outcome measures:visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations.RESULTS: The follow-up time was 11-36mo (21.4±7.13. Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL

  20. Adhesion and detachment of a capsule in axisymmetric flow

    Science.gov (United States)

    Keh, M. P.; Leal, L. G.

    2016-05-01

    The adhesion and detachment of a capsule on a solid boundary surface is studied via a combination of scaling theory and numerical simulation and the behavior is compared and contrasted with a vesicle. It is shown that the dominant physical property for both capsules and vesicles is the area dilation modulus Ks of the membrane. The nonzero shear modulus Gs for capsules increases the resistance to deformation and thus decreases slightly the equilibrium contact radius for an adhered capsule compared to an adhered vesicle. The detachment process in this study is due to an external axisymmetric flow. Unlike a rigid body that must be pulled away without change of shape, capsules (and vesicles) almost always detach dominantly by peeling in which the contact radius decreases but the minimum separation distance does not change until the final moments of detachment. Compared to a vesicle with the same Ks, a capsule maintains a more compact shape and is harder to elongate under a given external flow. Hence, the detachment process is slower for capsules compared to vesicles with the same Ks.