WorldWideScience

Sample records for anterior chamber paracentesis

  1. Anterior chamber paracentesis to improve diagnosis and treatment of infectious uveitis in South Africa.

    Science.gov (United States)

    Schaftenaar, Erik; Lecuona, Karin; Baarsma, Seerp; Meenken, Christina; Verjans, Georges; McIntyre, James; Peters, Remco

    2015-09-22

    Infectious uveitis is a significant cause of blindness in South Africa, especially among HIV-infected individuals. The visual outcome of uveitis depends on early clinical and laboratory diagnosis to guide therapeutic intervention. Analyses of aqueous humor, obtained by anterior chamber paracentesis, directs the differential diagnosis in infectious uveitis. However, although safe and potentially cost-effective, diagnostic anterior chamber paracentesis is not common practice in ophthalmic care across Africa. We seek to draw attention to this important procedure that could improve the diagnosis and prognosis of infectious uveitis.

  2. Effect of paracentesis on ocular cloxacillin concentration

    International Nuclear Information System (INIS)

    Salminen, L.

    1978-01-01

    The effect of interior chamber puncture on cloxacillin concentration in the rabbit eye after intravenous injection was studied using a radioactive tracer method. The enhancement in drug concentration caused by paracentesis was most immediate and significant in the iris-ciliary body preparation. It was soon followed by high cloxacillin concentration in the aqueous humour, which contributed to elevated cloxacillin levels in the cornea, lens and anterior vitreous body, when compared to normal material. Contrary to normal eyes, cloxacillin concentration in the cornea of the punctured eyes was higher than in the limbal area. The morphological changes occurring after paracentesis are discussed. The breakdown of the hydrodynamic equilibrium in the eye, suggested as the only change after paracentesis by Raviola (1974), cannot merely explain the cloxacillin concentration changes measured in the punctured eye. (author)

  3. EFFECTS OF FLUNIXIN MEGLUMINE CONJUNCTIVAL SHOT OVER THE HUMOR AQUEOUS PROTEIN OF DOGS SUBMITTED TO THE PARACENTESIS OF THE ANTERIOR CHAMBER AVALIAÇÃO DOS EFEITOS DA FLUNIXINA MEGLUMINA, POR VIA SUBCONJUNTIVAL, SOBRE A CONCENTRAÇÃO E PADRÃO PROTEICO DO HUMOR AQUOSO DE CÃES SUBMETIDOS À PARACENTESE DA CÂMARA ANTERIOR

    Directory of Open Access Journals (Sweden)

    Paula Diniz Galera

    2009-12-01

    Full Text Available

    Flunixin meglumine effects, over aqueous humor proteins of eyes on dogs who were submitted to paracentesis of the anterior chamber, were evaluated. To ten adult dogs clinically healthy were given a subconjunctival shot with flunixin meglumine (1.1mg/Kg on the right eye and sterilized saline solution 0.9% on the left eye, with the same volume. After general anesthesia, were submitted to two paracentesis of the both eyes to collect 0.2mL of first and second aqueous. The samples were submitted to Bradford test, wich proteins concentrations were  15.98mg/dL ± 4.48 e 11.46mg/dL ± 2.72 for the right and the left eyes, respectively, on the first paracentesis and 119.8mg/dL ± 6.74 e 120.63mg/dL ± 22.4 for the right and the left eyes, on the second paracentesis. There was no significant statistically differences between the protein values of the treated eyes in comparison with the control one. When compared, the proteins concentrations between the first and second paracentesis of the right and left eyes, statistic differences were found between these two moments (p<0.001. SDS-PAGE showed differences in the protein patterns of aqueous humor in result of the paracentesis.

    KEY WORDS: Aqueous humor, eye, flunixin meglumine, paracentesis, proteíns.

    Avaliaram-se os efeitos da flunixina meglumina, pela via subconjuntival, sobre as proteínas do humor aquoso de olhos de cães submetidos à paracentese da câmara anterior. Dez animais adultos, clinicamente sadios, receberam, por aplicação subconjuntival, flunixina meglumina (1,1mg/kg no olho direito e solução salina estéril a 0,9% no olho esquerdo, em igual volume. Mediante anestesia geral, foram submetidos a duas paracenteses de ambos os olhos para coleta de 0,2mL de aquoso primário e secundário, respectivamente. As amostras foram submetidas ao Teste de Bradford, cujas concentrações proteicas (média e desvio-padrão obtidas foram de 15

  4. Polymerase chain reaction in unilateral cases of presumed viral anterior uveitis

    Directory of Open Access Journals (Sweden)

    Shoughy SS

    2015-12-01

    Full Text Available Samir S Shoughy,1 Hind M Alkatan,2,4 Abdulelah A Al-Abdullah,2 Albarah El-Khani,2 Jolanda DF de Groot-Mijnes,3 Khalid F Tabbara1,4,5 1Department of Ophthalmology, The Eye Center and The Eye Foundation for Research in Ophthalmology, 2Department of Pathology & Laboratory Medicine and Uveitis Division, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia; 3Department of Virology and Ophthalmology, University Medical Center Utrecht, Utrecht, the Netherlands; 4Department of Ophthalmology, College of Medicine, King Saud University, Riyadh, Saudi Arabia; 5The Wilmer Ophthalmological Institute of The Johns Hopkins University School of Medicine, Baltimore, MD, USA Background and objectives: Anterior uveitis is the most common form of intraocular inflammation. The main aim of this study was to determine the viral etiology in patients with unilateral cases of anterior uveitis.Patients and methods: A total of 12 consecutive patients with the diagnosis of idiopathic unilateral anterior uveitis were included prospectively. Aqueous specimens were obtained from each patient by anterior chamber paracentesis and subjected to the detection of viral DNA/RNA genome by polymerase chain reaction assay for herpes simplex virus, varicella zoster virus, cytomegalovirus, Epstein–Barr virus, and rubella virus.Results: There were six male and six female patients. The mean age was 43 years, with an age range of 11–82 years. All 12 cases presented with unilateral anterior uveitis. In four (33% patients, polymerase chain reaction was positive for viral genome. Two patients were positive for herpes simplex virus type 1, one patient was positive for cytomegalovirus and one for Epstein–Barr virus.Conclusion: Recent molecular diagnostic assays would help in the identification of the causative agent in patients with unilateral anterior uveitis. Keywords: viral anterior uveitis, PCR, herpes simplex virus, cytomegalovirus, diffuse keratic precipitates, anterior chamber

  5. Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices

    Directory of Open Access Journals (Sweden)

    Alberto Domínguez-Vicent

    2014-08-01

    Full Text Available Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D. Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera and the Pentacam HR (single Scheimpflug camera systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured with the Galilei G4 and the Pentacam HR, respectively. The mean white-to-white distance measured was 11.84 ± 0.31 mm and 11.90 ± 0.43 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Mean pupil diameters were measured as 3.22 ± 0.58 mm and 3.22 ± 0.52 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Finally, the mean anterior chamber angle was 34.30 ± 2.86 degrees when it was measured with the Galilei G4, and 39.26 ± 2.85 degrees when measured with the Pentacam HR. A comparative analysis revealed that the Galilei G4 yielded a significantly lower (P0.05 for both devices were obtained for the white-to-white distance measurements. Conclusion: The Galilei G4 and Pentacam HR Scheimpflug systems cannot be used interchangeably because they produce significant measurement differences.

  6. [Two cases of Vogt-Koyanagi-Harada disease presenting shallow anterior chamber].

    Science.gov (United States)

    Takemoto, Daisuke; Ijiri, Shigeyuki; Shimizu, Michiharu; Higashide, Tomomi; Sugiyama, Kazuhisa

    2015-05-01

    We report two cases of Vogt-Koyanagi-Harada disease (VKH) in which shallow anterior chambers were improved after steroid pulse therapy. The patients were women aged 65 and 72. They had headaches, decreased visual acuity and shallow anterior chamber in both eyes. There was no inflammation in the anterior chamber. Ultrasound biomicroscopy (UBM) showed ciliary edema, ciliochoroidal detachment, and angle closure. One case showed high intraocular pressure (IOP), and a diagnosis of acute primary angle closure was made. Although cataract surgery was performed in the left eye, postoperative optical coherence tomography (OCT) revealed serous retinal detachment in both eyes. The shallow anterior chamber and UBM findings were improved and serous retinal detachment disappeared after steroid pulse therapy in both cases. VKH may cause shallow anterior chamber and angle closure. The inflammatory changes of VKH in the anterior segment, i. e. ciliary edema and ciliochoroidal detachment, may exacerbate the shallow anterior chambers and narrow angles and result in an acute increase in IOP in eyes with short axial length. VKH associated with shallow anterior chamber may be misdiagnosed as acute primary angle closure. For differential diagnosis, examinations of the ocular fundus including OCT are useful.

  7. Automatic anterior chamber angle assessment for HD-OCT images.

    Science.gov (United States)

    Tian, Jing; Marziliano, Pina; Baskaran, Mani; Wong, Hong-Tym; Aung, Tin

    2011-11-01

    Angle-closure glaucoma is a major blinding eye disease and could be detected by measuring the anterior chamber angle in the human eyes. High-definition OCT (Cirrus HD-OCT) is an emerging noninvasive, high-speed, and high-resolution imaging modality for the anterior segment of the eye. Here, we propose a novel algorithm which automatically detects a new landmark, Schwalbe's line, and measures the anterior chamber angle in the HD-OCT images. The distortion caused by refraction is corrected by dewarping the HD-OCT images, and three biometric measurements are defined to quantitatively assess the anterior chamber angle. The proposed algorithm was tested on 40 HD-OCT images of the eye and provided accurate measurements in about 1 second.

  8. VALIDITY OF PARACENTESIS IN DIAGNOSING BLUNT TRAUMA ABDOMEN

    Directory of Open Access Journals (Sweden)

    Fahad Bin Abdul Majeed

    2017-03-01

    Full Text Available BACKGROUND Blunt abdominal trauma is a common case that comes to an emergency department and it is the most easily missed diagnosis resulting in catastrophic consequences. Delay in diagnosing a case is due to the nonspecific character of the symptoms with which it presents. Clinical signs that could be elicited in blunt trauma abdomen are equally nonspecific. Thus, to avoid delay and save the life of the patient, a doctor has to depend on various investigations to rule out blunt trauma abdomen. The modalities which help include paracentesis, diagnostic peritoneal lavage, Focused Abdominal Sonography for Trauma (FAST and ContrastEnhanced Computed Tomography (CECT. To choose the right investigation for the right patient helps in saving precious lives. Validity of each investigation, availability, condition of the patient are the main points to look into before deciding on the right investigative modality. Paracentesis is the simplest investigation that could be done in emergency department and also at the site of accident to triage the patient. Paracentesis has low sensitivity to detect blunt trauma. FAST is a better investigation with higher validity rates than paracentesis. This study aims to validate paracentesis, which is the simplest and commonest investigation used to identify blunt abdominal trauma. MATERIALS AND METHODS In this study, 106 patients who fulfilled the inclusion and exclusion criteria were followed up by detailed history, clinical examination, paracentesis and FAST to identify blunt abdominal trauma and then compared with a gold standard investigation, which was assigned as CECT for haemodynamically stable patients and laparotomy for haemodynamically unstable patients. Commonest organs injured in blunt trauma and their management was noted. Patients were followed up till discharge or death. Subsequently, the data were compiled using excel sheet and evaluated using tables and charts. RESULTS Paracentesis is found to have a

  9. Measurements of canine aqueous humor inflammatory mediators and the effect of carprofen following anterior chamber paracentesis.

    Science.gov (United States)

    Pinard, Chantale L; Gauvin, Dominique; Moreau, Maxim; Martel-Pelletier, Johanne; Pelletier, Jean-Pierre; Troncy, Eric

    2011-09-01

    Phase I: To evaluate levels of prostaglandin E(2) (PGE(2) ), nitrites and nitrates (NO(x) ), tumor necrosis factor-alpha (TNF-α) and expression of inducible cyclo-oxygenase (COX-2), nitric oxide synthase (NOS-2), and matrix metalloproteinases (MMP-3 and -9) in canine aqueous humor following repeated anterior chamber paracenteses (ACP). Phase II: to evaluate the effect of carprofen on PGE(2) , NO(x) , and TNF-α in canine aqueous humor following ACP. Four beagles in phase I and 8 beagles in phase II. Phase I: ACP was performed at time (T) 0, 4 and 8 h. Phase II: A randomized, placebo-controlled cross-over design with four dogs per group where carprofen was given 4.4 mg/kg/day on day (D) 1, 2 and 3. ACP was performed at T0 and T1.5 on D3. Statistical analysis was performed with repeated measures anova and post hoc Tukey-Kramer multiple-comparison procedure. In phase II, TNF-α level was analyzed with a Wilcoxon signed-rank test. Phase I: PGE(2) significantly increased (P carprofen group (P = 0.037). NO(x) and TNF-α did not statistically increase in either group. Following ACP, significant increases in PGE(2) levels confirmed inflammation characterized by a rise of COX-2. The NO(x) pathway took longer to induce as compared with PGE(2) . Carprofen decreased PGE(2) levels and could help control intraocular inflammation. © 2011 American College of Veterinary Ophthalmologists.

  10. Glaucoma anterior chamber morphometry based on optical Scheimpflug images.

    Science.gov (United States)

    Alonso, Ruiz Simonato; Ambrósio Junior, Renato; Paranhos Junior, Augusto; Sakata, Lisandro Massanori; Ventura, Marcelo Palis

    2010-01-01

    To compare the performance of gonioscopy and noncontact morphometry with anterior chamber tomography (High Resolution Pentacam - HR) using optical Scheimpflug images in the evaluation of the anterior chamber angle (ACA). Transversal study. 112 eyes from 74 subjects evaluated at the Glaucoma Department, Fluminense Federal University, underwent gonioscopy and Pentacam HR. Using gonioscopy, the ACA was graded using the Shaffer Classification (SC) by a single experienced examiner masked to the Pentacam HR findings. Narrow angle was determined in eyes in which the posterior trabecular meshwork could not be seen in two or more quadrants on non-indentation gonioscopy (SC Grade 2 or less). Pentacam HR images of the nasal and temporal quadrants were evaluated by custom software to automatically obtain anterior chamber measurements, such as: anterior chamber angle (ACA), anterior chamber volume (ACV) and anterior chamber depth (ACD). Based on gonioscopy results, 74 (60.07%) eyes of patients classified as open-angle (SC 3 and 4) and 38 (33.93%) eyes of patients classified as narrow-angle (SC 1 and 2). Noncontact morphometry with Scheimpflug images revealed a mean ACA of 39.20 ± 5.31 degrees for open-angle and 21.18 ± 7.98 degrees for narrow-angle. The open-angle group showed significant greater ACV and ACD values when compared to narrow-angle group (ACV of 193 ± 36 mm³ vs. 90 ± 25 mm³, respectively, p<0.001; and ACD of 3,09 ± 0,42 mm vs. 1,55 ± 0,64 mm, respectively, p<0.0001.). In screening eyes with open-angle and narrow-angle with the Pentacam ACA of 20º (SC Grade 2) using the ROC curves, the analysis showed 52.6% of sensitivity and 100% of specificity. The Pentacam showed ability in detecting eyes at risk for angle closure analyzing ACV and ACD.

  11. Paracentesis as Surgical Intervention in Traumatic Hyphaema: Opinions and Practices of Nigerian Ophthalmologists

    Directory of Open Access Journals (Sweden)

    Okosa Michael Chuka

    2012-01-01

    Full Text Available Introduction Various aspects of management of traumatic hyphaema are enmeshed in controversy. Surgery is done to prevent complications: optic atrophy and corneal blood staining occurring if a high risk exists of either or both occurring. Circumstances considered high risk do not enjoy universal consensus. Objectives To determine what Nigerian ophthalmologists consider absolute indications for surgical intervention by means of anterior chamber paracentesis and hyphaema washout in closed globe traumatic hyphaema, evaluate these absolute indications, and attempt to evolve a guideline for surgical intervention based on areas of consensus and disagreement. Method A semi-structured, pre-tested questionnaire with responses analyzed with SPSS 11 software. Result Near universal agreement on indication exist on early corneal blood staining and sickle cell haemoglobinopathy. Differing views concern blackball, volume and duration of hyphaema and secondary hypertension-associated hyphaema. However, it appears surgery is embarked on earlier than other practitioners elsewhere may consider necessary. Conclusion Risk level for non-surgical management against risk and benefit of surgery should be evaluated for each individual before surgery.

  12. Abdominal paracentesis and thoracocentesis.

    Science.gov (United States)

    Lee, Ser Yee; Pormento, James G; Koong, Heng Nung

    2009-04-01

    Abdominal paracentesis and thoracocentesis are common bedside procedures with diagnostic, therapeutic and palliative roles. We describe a useful and familiar a useful and familiar technique with the use of a multiple lumen catheter commonly used for central venous line insertion for drainage of ascites or moderate to large pleural effusions. The use of a multiple lumen catheter allows easier and more rapid aspiration of fluid with a smaller probability of the side holes being blocked as compared to the standard needle or single catheter methods. This is particularly useful in situations where the dedicated commercial kits for thoracocentesis and abdominal paracentesis are not readily available.

  13. Polymerase chain reaction in unilateral cases of presumed viral anterior uveitis.

    Science.gov (United States)

    Shoughy, Samir S; Alkatan, Hind M; Al-Abdullah, Abdulelah A; El-Khani, Albarah; de Groot-Mijnes, Jolanda Df; Tabbara, Khalid F

    2015-01-01

    Anterior uveitis is the most common form of intraocular inflammation. The main aim of this study was to determine the viral etiology in patients with unilateral cases of anterior uveitis. A total of 12 consecutive patients with the diagnosis of idiopathic unilateral anterior uveitis were included prospectively. Aqueous specimens were obtained from each patient by anterior chamber paracentesis and subjected to the detection of viral DNA/RNA genome by polymerase chain reaction assay for herpes simplex virus, varicella zoster virus, cytomegalovirus, Epstein-Barr virus, and rubella virus. There were six male and six female patients. The mean age was 43 years, with an age range of 11-82 years. All 12 cases presented with unilateral anterior uveitis. In four (33%) patients, polymerase chain reaction was positive for viral genome. Two patients were positive for herpes simplex virus type 1, one patient was positive for cytomegalovirus and one for Epstein-Barr virus. Recent molecular diagnostic assays would help in the identification of the causative agent in patients with unilateral anterior uveitis.

  14. Predictive factors for anterior chamber fibrin formation after vitreoretinal surgery

    Directory of Open Access Journals (Sweden)

    Leonardo Provetti Cunha

    2014-04-01

    Full Text Available Purpose: The aim of this study was to investigate possible predictive factors related to anterior chamber fibrin formation after vitreoretinal surgery in a large series of patients. Methods: The data of 185 eyes of 185 patients submitted to vitreoretinal surgery was reviewed. The following variables were evaluated: the postoperatively presence of fibrin, age, diabetes mellitus, the vitrectomy system gauge (20, 23 or 25 gauge, the type of vitreous substitute, the influence of prior surgical procedures and the combination with cataract extraction. To evaluate predictive factors for anterior chamber fibrin formation, univariate analysis was performed. A multivariate stepwise logistic regression model was adjusted to investigate factors associated with fibrin formation (p<0.05. Results: Fibrinoid anterior chamber reaction was found in 12 (6.4% patients. For multivariate logistic regression analysis, balanced salt solution (BSS, the chance of fibrin occurrence was 5 times greater (odds ratio 4.83, CI 95% 1.302 - 17.892; p=0.019, while combination with phacoemulsification increased the chance of fibrin formation by 20 times (odds ratio 20, CI 95% 2.480 - 161.347; p=0.005. No significant difference was found regarding other variables. Conclusion: Anterior chamber fibrin formation is an unwanted complication after vitreoretinal surgery. Factors such as combined performance of phacoemulsification and the use of balanced salt solution as a vitreous substitute may predispose the occurrence of this complication.

  15. Evaluation of the anterior chamber angle in pseudoexfoliation syndrome.

    Science.gov (United States)

    Iwanejko, Małgorzata; Turno-Kręcicka, Anna; Tomczyk-Socha, Martyna; Kaczorowski, Kamil; Grzybowski, Andrzej; Misiuk-Hojło, Marta

    2017-08-01

    Pseudoexfoliation syndrome (PEX) is the most frequently identifiable cause of secondary open-angle glaucoma, known as pseudoexfoliation glaucoma. The exact pathophysiology and etiology of PEX and associated glaucoma remains obscure. The purpose of this study was to determine the differences in the morphology of the anterior chamber angle in people with pseudoexfoliation syndrome and pseudoexfoliation glaucoma compared to a control group. We also evaluated the correlation between intraocular pressure (IOP) and pigmentation of the angle with the amount of exfoliated material in the anterior segment. The study group was composed of 155 eyes from 103 patients aged between 43 and 86 years. Each patient underwent a complete ophthalmological examination. Some difference was found in intraocular pressure between the PEX group and the control group and between the pseudoexfoliation glaucoma group and the control group, but no significant difference was found between the 2 study groups. There was a significant difference in the incidence of some degree of pigmentation in the anterior chamber angle and no difference in the widths of the angle between each group. A significant positive relationship was observed between intraocular pressure and the degree of pigmentation of the anterior chamber angle in both the PEX group and the pseudoexfoliation glaucoma group. The results of this study indicate that the amount of pigmentation and exfoliation material in the anterior segment significantly correlates with the level of IOP and possibly with the degree of trabecular dysfunction. It seems that for clear identification of PEX and pseudoexfoliation glaucoma factors, clinical assessment appears to be insufficient.

  16. Phakic iris-fixated intraocular lens placement in the anterior chamber: effects on aqueous flow.

    Science.gov (United States)

    Repetto, Rodolfo; Pralits, Jan O; Siggers, Jennifer H; Soleri, Paolo

    2015-05-01

    Phakic intraocular lenses (pIOLs) are used for correcting vision; in this paper we investigate the fluid dynamical effects of an iris-fixated lens in the anterior chamber. In particular, we focus on changes in the wall shear stress (WSS) on the cornea and iris, which could be responsible for endothelial and pigment cell loss, respectively, and also on the possible increase of the intraocular pressure, which is known to correlate with the incidence of secondary glaucoma. We use a mathematical model to study fluid flow in the anterior chamber in the presence of a pIOL. The governing equations are solved numerically using the open source software OpenFOAM. We use an idealized standard geometry for the anterior chamber and a realistic geometric description of the pIOL. We consider separately the main mechanisms that produce fluid flow in the anterior chamber. The numerical simulations allow us to obtain a detailed description of the velocity and pressure distribution in the anterior chamber, and indicated that implantation of the pIOL significantly modifies the fluid dynamics in the anterior chamber. However, lens implantation has negligible influence on the intraocular pressure and does not produce a significant increase of the shear stress on the cornea, while the shear stress on the iris, although increased, is not enough to cause detachment of cells. We conclude that alterations in the fluid dynamics in the anterior chamber as a result of lens implantation are unlikely to be the cause of medical complications associated with its use.

  17. Evaluation of the Effects of Menstrual Cycle on Anterior Chamber Parameters as Measured with Pentacam

    Directory of Open Access Journals (Sweden)

    Arzu Seyhan Karatepe

    2013-01-01

    Full Text Available Pur po se: To evaluate the effects of endogenous gonadotropic hormones (follicle-stimulating hormone, luteinizing hormone and sex steroids (progesterone, estrogen to anterior segment parameters. Ma te ri al and Met hod: Thirty healthy females who had a menstrual cycle of 28±1 day and with a mean age of 36.5±7.56 (range, 20 – 46 years were included in the study. Starting from the first day of their cycle, Pentacam Scheimpflug camera measurements were performed on the 1st, 3rd, 7th, 12th, 16th, 21st, 26th, and 28th days. The central corneal thickness, anterior chamber depth, anterior segment volume, keratometric values, anterior chamber angle value, and pupilla diameter of both eyes were evaluated. Repeated measures analysis of variance test was used for statistical analysis. Re sults: No difference that reaches statistical significance was found in the means of central corneal thickness, anterior chamber volume, keratometric values, anterior chamber angle, and pupilla diameter between the days. Mean anterior chamber depth measurement of the right eyes on the 1st day was 2.72±0.44 mm, whereas it was 2.77±0.46 mm on the 26th day. Mean anterior chamber depth measurement of the left eyes on the 1st day was 2.74±0.42 mm, whereas it was 2.80±0.43 mm on the 26th day. This increment of anterior chamber depth value from the 1st to the 26th days was found to be statistically significant (p≤0.05. Dis cus si on: Progesterone and estrogen that rise in the second half of the menstrual cycle might have a deepening effect on the anterior chamber. These findings should be further investigated with more profound studies that also evaluate the hormonal values and their correlations with anterior segment parameters. (Turk J Ophthalmol 2013; 43: 15-8

  18. Short-term variation in ocular anterior chamber angle using Scheimpflug photography

    OpenAIRE

    A. Rubin

    2010-01-01

    Purpose: To investigate short-term variation of ocular Anterior Chamber Angle (ACA) within and across the different meridians of young, healthy eyes. Method: Scheimpflug photography (via an  Oculus Pentacam) was used to repeatedly measure the anterior segment of the right eyes of three young females, all aged 22 years.  For each individual, ten consecutive maps were determined over a short time period and each map contained information for the chamber angles of different meridians acr...

  19. Gnathostomiasis of the anterior chamber

    Directory of Open Access Journals (Sweden)

    Barua P

    2007-01-01

    Full Text Available Ocular involvement with Gnathostoma spinigerum occurs years after the initial infection that is acquired by ingestion of poorly cooked, pickled seafood or water contaminated with third stage larvae. Here we report a case of gnathostomiasis of the left eye of a 32-year-old lady hailing from Meghalaya, India. Her vision had deteriorated to hand movement. Slit lamp examination revealed a live, actively motile worm in the anterior chamber, which was extracted by supra temporal limbal incision and visual acuity was restored.

  20. 'Blue bubble' technique: an ab interno approach for Descemet separation in deep anterior lamellar keratoplasty using trypan blue stained viscoelastic device.

    Science.gov (United States)

    Livny, Eitan; Bahar, Irit; Hammel, Naama; Nahum, Yoav

    2018-04-01

    In this study, we examined a novel variant of 'big-bubble' deep anterior lamellar keratoplasty using trypan-blue-stained viscoelastic device for the creation of a pre-descemetic bubble. Ten corneoscleral rims were mounted on an artificial anterior chamber (AC). The AC was filled with air through a limbal paracentesis. A Melles' triangulated spatula was inserted through the paracentesis, with its tip penetrating the AC, was then slightly retracted and pushed into the deep stroma above the roof of the paracentesis. A mixture of trypan blue and viscoelastic device (Healon, Abbott Medical Optics, Abbott Park, Illinois) was injected into this intra-stromal pocket using a 27-G cannula to create a pre-descemetic separation bubble. Bubble type and visualization of dyed viscoelastic device were noted. The method was later employed in three cases. In all 10 corneoscleral rims, the technique successfully created a visible pre-descemetic (type 1) bubble that could be expanded up to the predicted diameter of trephination. Subsequent trephination and the removal of corneal stroma were uneventful. In two out of four clinical cases, a type 1 bubble was created, while in two others, visco-dissection failed and dyed viscoelastic was seen in the AC. The presented technique holds promise of being a relatively easy to perform, predictable and well-controlled alternative for achieving a type 1 bubble during deep anterior lamellar keratoplasty surgery. The trypan-blue-stained viscoelastic device facilitates proper visualization and control of the separation bubble and assists in identifying the penetrance to the separation bubble prior to removal of the stromal cap. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  1. Surgical management of anterior chamber epithelial cysts.

    Science.gov (United States)

    Haller, Julia A; Stark, Walter J; Azab, Amr; Thomsen, Robert W; Gottsch, John D

    2003-03-01

    To review management strategies for treatment of anterior chamber epithelial cysts. Retrospective review of consecutive interventional case series. Charts of patients treated for epithelial ingrowth over a 10-year period by a single surgeon were reviewed. Cases of anterior chamber epithelial cysts were identified and recorded, including details of ocular history, preoperative and postoperative acuity, intraocular pressure (IOP), and ocular examination, type of surgical intervention, and details of further procedures performed. Seven eyes with epithelial cysts were identified. Patient age ranged from 1.5 to 53 years at presentation. Four patients were children. In four eyes, cysts were secondary to trauma, one case was presumably congenital, one case developed after corneal perforation in an eye with Terrien's marginal degeneration, and one case developed after penetrating keratoplasty (PK). Three eyes were treated with vitrectomy, en bloc resection of the cyst and associated tissue, fluid-air exchange and cryotherapy. The last four eyes were treated with a new conservative strategy of cyst aspiration (three cases) or local excision (one keratin "pearl" cyst), and endolaser photocoagulation of the collapsed cyst wall/base. All epithelial tissue was successfully eradicated by clinical criteria; one case required repeat excision (follow-up, 9 to 78 months, mean 45). Two eyes required later surgery for elevated IOP, two for cataract extraction and one for repeat PK. Final visual acuity ranged from 20/20 to hand motions, depending on associated ocular damage. Best-corrected visual results were obtained in the more conservatively managed eyes. Anterior chamber epithelial cysts can be managed conservatively in selected cases with good results. This strategy may be particularly useful in children's eyes, where preservation of the lens, iris, and other structures may facilitate amblyopia management. Copyright 2003 by Elsevier Science Inc.

  2. Clearance from the anterior chamber of RBCs from human diabetics

    International Nuclear Information System (INIS)

    Williams, G.A.; Hatchell, D.L.; Collier, B.D.; Knobel, J.

    1984-01-01

    Erythrocytes from diabetic patients manifest decreased deformability and increased adherence. These abnormal membrane properties may diminish the ability of erythrocytes (RBCs) from diabetics to undergo deformation in passage through the trabecular meshwork. Using sodium chromate Cr 51-labeled RBCs from type I diabetic patients with proliferative retinopathy and normal control subjects, we studied RBC clearance from the rabbit anterior chamber. The mean time for 50% clearance (T50) of RBCs from diabetics (76 hours) was significantly longer than that for RBCs from normal subjects (19.5 hours). In this model, RBCs from diabetics have a slower clearance from the anterior chamber than do RBCs from normal subjects

  3. Effect of large volume paracentesis on plasma volume--a cause of hypovolemia

    International Nuclear Information System (INIS)

    Kao, H.W.; Rakov, N.E.; Savage, E.; Reynolds, T.B.

    1985-01-01

    Large volume paracentesis, while effectively relieving symptoms in patients with tense ascites, has been generally avoided due to reports of complications attributed to an acute reduction in intravascular volume. Measurements of plasma volume in these subjects have been by indirect methods and have not uniformly confirmed hypovolemia. We have prospectively evaluated 18 patients (20 paracenteses) with tense ascites and peripheral edema due to chronic liver disease undergoing 5 liter paracentesis for relief of symptoms. Plasma volume pre- and postparacentesis was assessed by a 125 I-labeled human serum albumin dilution technique as well as by the change in hematocrit and postural blood pressure difference. No significant change in serum sodium, urea nitrogen, hematocrit or postural systolic blood pressure difference was noted at 24 or 48 hr after paracentesis. Serum creatinine at 24 hr after paracentesis was unchanged but a small but statistically significant increase in serum creatinine was noted at 48 hr postparacentesis. Plasma volume changed -2.7% (n = 6, not statistically significant) during the first 24 hr and -2.8% (n = 12, not statistically significant) during the 0- to 48-hr period. No complications from paracentesis were noted. These results suggest that 5 liter paracentesis for relief of symptoms is safe in patients with tense ascites and peripheral edema from chronic liver disease

  4. [Analysis of refractive status after cataract surgery in age-related cataract patients with shallow anterior chamber].

    Science.gov (United States)

    Yang, Fei; Hou, Xianru; Wu, Huijuan; Bao, Yongzhen

    2014-02-01

    To evaluate the characteristics of postoperative refractive status in age-related cataract patients with shallow anterior chamber and the correlation between pre-operative anterior chamber depth and postoperative refractive status. Prospective case-control study. Sixty-eight cases (90 eyes) with age-related cataract were recruited from October 2010 to January 2012 in People's Hospital Peking University including 28 cases (34 eyes) in control group and 40 cases (56 eyes) in shallow anterior chamber group according to anterior chamber depth (ACD) measured by Pentacam system. Axial length and keratometer were measured by IOL Master and intraocular lens power was calculated using SRK/T formula. Postoperative refraction, ACD and comprehensive eye examination were performed at 1 month and 3 months after cataract surgery. Using SPSS13.0 software to establish a database, the two groups were compared with independent samples t-test and correlation analysis were performed with binary logical regression. The postoperative refractive deviation at 1 month were (-0.39 ± 0.62) D in control group and (+0.73 ± 0.26) D in shallow anterior chamber group respectively which present statistical significance between the two groups (P = 0.00, t = 3.67); the postoperative refractive deviation in 3 month was (-0.37 ± 0.62) D in control group and (+0.79 ± 0.28) D in shallow anterior chamber group operatively which present statistical significance between the two groups (P = 0.00, t = 3.33). In shallow anterior chamber group, with the shallower of ACD, the greater of refractive deviation (P = 0.00, r1 month = -0.57, r3 months = -0.61). Hyperopic shift existed in age-related cataract patients with shallow anterior chamber and the shallower of ACD was, the greater of hyperopic shift happened.

  5. A Case of Retained Graphite Anterior Chamber Foreign Body Masquerading as Stromal Keratitis

    Science.gov (United States)

    Han, Eun Ryung; Wee, Won Ryang; Lee, Jin Hak

    2011-01-01

    We report a case of a retained graphite anterior chamber foreign body that was masquerading as stromal keratitis. A 28-year-old male visited with complaints of visual disturbance and hyperemia in his right eye for four weeks. On initial examination, he presented with a stromal edema involving the inferior half of the cornea, epithelial microcysts, and moderate chamber inflammation. Suspecting herpetic stromal keratitis, he was treated with anti-viral and anti-inflammatory agents. One month after the initial visit, anterior chamber inflammation was improved and his visual acuity recovered to 20/20, but subtle corneal edema still remained. On tapering the medication, after three months, a foreign body was incidentally identified in the inferior chamber angle and was surgically removed resulting in complete resolution of corneal edema. The removed foreign body was a fragment of graphite and he subsequently disclosed a trauma with mechanical pencil 12 years earlier. This case showed that the presence of an anterior chamber foreign body should always be considered in the differential diagnosis of idiopathic localized corneal edema. PMID:21461226

  6. RETAINED STONE PIECE IN ANTERIOR CHAMBER

    Directory of Open Access Journals (Sweden)

    ZvornicaninJasmin, Nadarevic-VodencarevicAmra

    2015-04-01

    Full Text Available ABSTRACT We read with interest the article by Surekha et al. regarding the retained stone piece in anterior chamber. Similar to the results of previous studies, the authors found that delayed intraocular foreign body (IOFB management can result in good visual outcome without an apparent increased risk of endophthalmitis or other deleterious side effects. However, the authors failed to explain the exact reason for the diminution of vision in patients left eye. It is unclear what the uncorrected visual acuity was and what kind of correction was used, more precisely type and amount of cylinder, given the presence of the corneal opacity. Since the size of the IOFB is approximately 4x4x1mm, significant irido-corneal angle changes resulting in intraocular pressure raise and optic nerve head damage can be expected. Traumatic glaucoma following open globe injury can occur in 2.7 to 19% of cases, with several risk factors associated with glaucoma development (advanced age, poor visual acuity at presentation,perforating rather than penetrating ocular injury,lens injury, presence of vitreous hemorrhage and presence of an IOFB. Earlier reportsof latetraumaticoptic neuropathy onset, even after several years, indicate that this possibility cannot be completely ruled out too. Therefore, repeated intraocular pressure measurements, gonioscopy, pupillary reaction assessment, together with through posterior segment examination including visual field and optical coherence tomography examinations can be useful in determining the possible optic nerve damage as one of the possible reasons for visual acuity reduction. The authors did not suggest any operative treatment at this time. However, it should bear in mind that the inert anterior chamber IOFB could be a risk factor for non-infectious endophthalmitis development even after many years. Also, long term retained anterior chamber foreign body leads to permanent endothelial cell loss and can even result in a corneal

  7. Hong's grading for evaluating anterior chamber angle width.

    Science.gov (United States)

    Kim, Seok Hwan; Kang, Ja Heon; Park, Ki Ho; Hong, Chul

    2012-11-01

    To compare Hong's grading method with anterior segment optical coherence tomography (AS-OCT), gonioscopy, and the dark-room prone-position test (DRPT) for evaluating anterior chamber width. The anterior chamber angle was graded using Hong's grading method, and Hong's angle width was calculated from the arctangent of Hong's grades. The correlation between Hong's angle width and AS-OCT parameters was analyzed. The area under the receiver operating characteristic curve (AUC) for Hong's grading method when discriminating between narrow and open angles as determined by gonioscopy was calculated. Correlation analysis was performed between Hong's angle width and intraocular pressure (IOP) changes determined by DRPT. A total of 60 subjects were enrolled. Of these subjects, 53.5 % had a narrow angle. Hong's angle width correlated significantly with the AS-OCT parameters (r = 0.562-0.719, P < 0.01). A Bland-Altman plot showed relatively good agreement between Hong's angle width and the angle width obtained by AS-OCT. The ability of Hong's grading method to discriminate between open and narrow angles was good (AUC = 0.868, 95 % CI 0.756-0.942). A significant linear correlation was found between Hong's angle width and IOP change determined by DRPT (r = -0.761, P < 0.01). Hong's grading method is useful for detecting narrow angles. Hong's grading correlated well with AS-OCT parameters and DRPT.

  8. Anterior capsular support for posterior chamber intraocular lenses following vitreous loss in endocapsular surgery

    Directory of Open Access Journals (Sweden)

    Jacob Pushpa

    1993-01-01

    Full Text Available We used anterior capsular support for posterior chamber intraocular lenses (PC IOLs in fourteen eyes with large posterior capsular ruptures. An endocapsular technique preserved the anterior capsule and facilitated implantation. With a median follow up of 8.5 months, all patients had a visual acuity of 6/9 or better. One lens was lost in the vitreous and one patient had a clinically significant cystoid macular edema. In the event of a posterior capsular rupture we suggest this technique as an alternative to anterior chamber or scleral-fixated lenses

  9. [Pigment dispersion syndrome and pigmentary glaucoma. Morphometric analysis of the anterior chamber segment with SL-OCT].

    Science.gov (United States)

    Birner, B; Tourtas, T; Wessel, J M; Jünemann, A G; Mardin, C Y; Kruse, F E; Laemmer, R

    2014-01-01

    The purpose of this study was to analyze if anterior chamber parameters are risk factors for the development of pigment dispersion syndrome (PDS) and/or for the conversion to pigmentary glaucoma (PG). This study included a total of 63 eyes from 35 patients with PDS and PG and 65 eyes from 49 unaffected volunteers as the control group. The following parameters were measured by slit lamp optical coherence tomography (SL-OCT): anterior chamber volume (ACV) and depth (ACD), angle opening distance (AOD) and the trabecular iris space area (TISA) at 500 µm and 750 μm from the scleral spur. Comparisons between the following groups were performed: between the PDS/PG and the control group, between PDS and PG and between male and female patients. The results of ACV, ACD, AOD and TISA were significantly higher in PDS/PG patients when compared to the control group. There were no significant differences between PDS and PG. The gender-specific comparison also showed no significant differences. Significantly higher anterior chamber parameters are a possible risk factor for development of PDS; however, a higher risk of conversion to PG does not seem to correlate with increased anterior chamber parameters. The parameters of the anterior chamber are apparently not associated with the male predominance of PDS and PG.

  10. Association of biometric factors with anterior chamber angle widening and intraocular pressure reduction after uneventful phacoemulsification for cataract.

    Science.gov (United States)

    Huang, Guofu; Gonzalez, Eduardo; Lee, Roland; Chen, Yi-Chun; He, Mingguang; Lin, Shan C

    2012-01-01

    To evaluate anterior chamber biometric factors associated with the degree of angle widening and intraocular pressure (IOP) reduction after phacoemulsification. University of California, San Francisco, California, USA. Case series. Anterior chamber parameters obtained by anterior segment coherence tomography were compared preoperatively and 3 months postoperatively. Measurements included the angle opening distance 500 μm anterior to the scleral spur (AOD500), trabecular-iris space area 500 μm from the scleral spur (TISA500), iris curvature (I-Curv), anterior chamber angle (ACA), trabecular-iris space area, anterior chamber volume, anterior chamber width, and lens vault (LV). The study enrolled 73 eyes. The mean patient age was 77.45 years ± 7.84 (SD); 65.75% of patients were women. From preoperatively to 3 months postoperatively, the mean AOD500 increased significantly (0.254 ± 0.105 to 0.433 ± 0.108 mm) and the mean IOP decreased significantly (14.97 ± 3.35 to 12.62 ± 3.37 mm Hg) (P<.001). The reduction in IOP was correlated with the increase in AOD500 (r = 0.240, P=.041) and preoperative LV (r = 0.235, P=.045). After adjusting for related factors, AOD500 widening was positively correlated with LV (β = 0.458, P=.044) and I-Curv (β = 0.235, P=.043) and negatively correlated with preoperative TISA500 (β = -0.269, P=.025) and ACA (β = -0.919, P=.027). Surgically induced AOD widening was significantly correlated with anterior chamber biometric factors. Preoperative LV appears to be a significant factor in angle widening and IOP reduction after phacoemulsification. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Colloids Versus Albumin in Large Volume Paracentesis to Prevent Circulatory Dysfunction: Evidence-based Case Report.

    Science.gov (United States)

    Widjaja, Felix F; Khairan, Paramita; Kamelia, Telly; Hasan, Irsan

    2016-04-01

    Large volume paracentesis may cause paracentesis induced circulatory dysfunction (PICD). Albumin is recommended to prevent this abnormality. Meanwhile, the price of albumin is too expensive and there should be another alternative that may prevent PICD. This report aimed to compare albumin to colloids in preventing PICD. Search strategy was done using PubMed, Scopus, Proquest, dan Academic Health Complete from EBSCO with keywords of "ascites", "albumin", "colloid", "dextran", "hydroxyethyl starch", "gelatin", and "paracentesis induced circulatory dysfunction". Articles was limited to randomized clinical trial and meta-analysis with clinical question of "In hepatic cirrhotic patient undergone large volume paracentesis, whether colloids were similar to albumin to prevent PICD". We found one meta-analysis and four randomized clinical trials (RCT). A meta analysis showed that albumin was still superior of which odds ratio 0.34 (0.23-0.51). Three RCTs showed the same results and one RCT showed albumin was not superior than colloids. We conclude that colloids could not constitute albumin to prevent PICD, but colloids still have a role in patient who undergone paracentesis less than five liters.

  12. OVA-specific CD8(+)T cells do not express granzyme B during anterior chamber associated immune deviation

    NARCIS (Netherlands)

    Ren, Y.; Yang, P.; Li, B.; Gao, Y.; Zhou, H.; Huang, X.; Zhu, L.; Kijlstra, A.

    2006-01-01

    To examine antigen (Ag)-specific CTL response during anterior chamber associated immune deviation (ACAID). Methods OVA or OVA257-264 peptide was injected into the anterior chamber (AC) of C57BL/6 mice. There were 16 mice in each ACAID group induced with OVA or OVA257-264 peptide. The mice were

  13. The correlation between variation of visual acuity and the anterior chamber depth in the early period after phacoemulsification

    Directory of Open Access Journals (Sweden)

    Kai-jian CHEN

    2011-04-01

    Full Text Available Objective To investigate the correlation between the visual acuity variation and the anterior chamber depth in the early period after phacoemulsification.Methods Thirty-six eyes of 32 patients with age-related cataract underwent 3.2mm clear corneal incision phacoemulsification and intraocular lens(IOL implantation.The visual acuity was examined and horizontal curvature(K1,vertical curvature(K2,corneal astigmatism,and anterior chamber depth were measured with IOL-master preoperatively and also on 1,3,7 and 15 postoperative days.The changes in parameters were compared,and the correlations among visual acuity,corneal astigmatism and anterior chamber depth were analyzed.Results Before operation and 1d,3d,7d and 15d after operation,the corneal astigmatism was-0.87±0.40D,-1.92±1.38D,-1.69±1.13D,-1.45±0.79D and-1.36±0.74D;the anterior chamber depth was 3.08±0.35mm,4.04±0.38mm,4.28±0.29mm,4.22±0.17mm and 4.22±0.16mm;the visual acuity was 0.18±0.10,0.44±0.14,0.59±0.12,0.61±0.11 and 0.62±0.14.Significant difference was found between pre-operative and postoperative visual acuity,corneal astigmatism and anterior chamber depth,and it was also found in corneal astigmatism between 1d and 15d post operation(P < 0.05,as well as in anterior chamber depth and visual acuity between 1d and 3d post operation(P < 0.05.A positive correlation was found between visual acuity and corneal astigmatism on 1d(r=0.42,P < 0.05,3d(r=0.35,P < 0.05 and 7d(r=0.35,P < 0.05 post operation;and a negative correlation was found between visual acuity and anterior chamber depth on 3d(r=-0.29,P < 0.05,7d(r=-0.43,P < 0.01 and 15d(r=-0.37,P < 0.05 post operation.Conclusion Both the corneal astigmatism and the anterior chamber depth are correlated with the visual acuity variation in the early period after phacoemulsification.

  14. Reversal of retinal and optic disc ischemia in a patient with sickle cell trait and glaucoma secondary to traumatic hyphema.

    Science.gov (United States)

    Wax, M B; Ridley, M E; Magargal, L E

    1982-07-01

    A 14-year-old black boy with sickle cell trait, who sustained a traumatic hyphema, developed moderately elevated intraocular pressure that failed to respond to carbonic anhydrase inhibitors and osmotic agents. On the tenth postinjury day, a sudden increased cupping of the optic disc and partial central retinal artery obstruction caused painless loss of vision. Reversal of the cupping, the retinal ischemia, and the intraocular pressure was documented following anterior chamber paracentesis, and visual acuity returned to 6/6. Pathophysiology of the posterior ischemia is discussed. This case documents the potentially debilitating course of traumatic hyphema in "benign" sickle cell trait and its avoidance with proper management. The authors endorse recent suggestions for careful observation of any sickle cell patient with traumatic hyphema, and recommend anterior chamber paracentesis, supplemental oxygen, and avoidance of osmotic agents, if secondary glaucoma develops following the initial trauma.

  15. Nitric oxide levels in the anterior chamber of vitrectomized eyes with silicon oil

    Directory of Open Access Journals (Sweden)

    Paulo Escarião

    2013-10-01

    Full Text Available PURPOSE: To investigate the nitric oxide levels in the anterior chamber of eyes who underwent pars plana vitrectomy (PPV with silicone oil. METHODS: Patients who underwent PPV with silicon oil injection, from february 2005 to august 2007, were selected. Nine patients (nine eyes participated in the study (five women and four men. Nitric oxide concentration was quantified after the aspiration of aqueous humor samples during the procedure of silicon oil removal. Data such as: oil emulsification; presence of oil in the anterior chamber; intraocular pressure and time with silicone oil were evaluated. Values of p <0.05 were considered to be statistically significant. RESULTS: A positive correlation between nitric oxide concentration and time with silicon oil in the vitreous cavity (r=0.799 was observed. The nitric oxide concentration was significantly higher (p=0.02 in patients with silicon oil more than 24 months (0.90µmol/ml ± 0.59, n=3 in the vitreous cavity comparing to patients with less than 24 months (0.19µmol/ml ± 0.10, n=6. CONCLUSION: A positive correlation linking silicone oil time in the vitreous cavity with the nitric oxide concentration in the anterior chamber was observed.

  16. A new slit lamp-based technique for anterior chamber angle estimation.

    Science.gov (United States)

    Gispets, Joan; Cardona, Genís; Tomàs, Núria; Fusté, Cèlia; Binns, Alison; Fortes, Miguel A

    2014-06-01

    To design and test a new noninvasive method for anterior chamber angle (ACA) estimation based on the slit lamp that is accessible to all eye-care professionals. A new technique (slit lamp anterior chamber estimation [SLACE]) that aims to overcome some of the limitations of the van Herick procedure was designed. The technique, which only requires a slit lamp, was applied to estimate the ACA of 50 participants (100 eyes) using two different slit lamp models, and results were compared with gonioscopy as the clinical standard. The Spearman nonparametric correlation between ACA values as determined by gonioscopy and SLACE were 0.81 (p gonioscopy (Spaeth classification). The SLACE technique, when compared with gonioscopy, displayed good accuracy in the detection of narrow angles, and it may be useful for eye-care clinicians without access to expensive alternative equipment or those who cannot perform gonioscopy because of legal constraints regarding the use of diagnostic drugs.

  17. Anterior chamber angle assessment using gonioscopy and ultrasound biomicroscopy.

    Science.gov (United States)

    Narayanaswamy, Arun; Vijaya, Lingam; Shantha, B; Baskaran, Mani; Sathidevi, A V; Baluswamy, Sukumar

    2004-01-01

    Comparison of anterior chamber angle measurements using ultrasound biomicroscopy (UBM) and gonioscopy. Five hundred subjects were evaluated for grading of angle width by the Shaffer method. UBM was done in the same group to document angle width, angle opening distance (AOD 500), and anterior chamber depth. Biometric parameters were documented in all subjects. UBM and gonioscopic findings were compared. A study was conducted in 282 men and 218 women with a mean age of 57.32 +/- 12.48 years. Gonioscopic grading was used to segregate occludable (slit-like, grades 1 and 2) from nonoccludable (grades 3 and 4) angles. Subjective assessment by gonioscopy resulted in an overestimation of angle width within the occludable group when compared with values obtained by UBM. This did not affect the segregation of occludable versus nonoccludable angles by gonioscopy. Biometric parameters in eyes with occludable angles were significantly lower in comparison with eyes with nonoccludable angles, except for lens thickness. AOD 500 correlated well with angle width. We concluded that clinical segregation into occludable and nonoccludable angles by an experienced observer using gonioscopy is fairly accurate. However, UBM is required for objective quantification of angles, and AOD 500 can be a reliable and standard parameter to grade angle width.

  18. Surgical outcomes of 23-gauge transconjunctival pars plana vitrectomy combined with lensectomy for glaucomatous eyes with extremely shallow anterior chamber and cataract.

    Science.gov (United States)

    Zhang, Zhaotian; Zhang, Shaochong; Jiang, Xintong; Qiu, Suo; Wei, Yantao

    2016-01-04

    Glaucoma combined with an extremely shallow anterior chamber and cataracts remains as a complex condition to deal with. And the emergence of microincision vitrectomy surgery (MIVS) system may provide an ideal option for the treatment of that. We report a clinical study of surgical outcomes of 23-gauge transconjunctival pars plana vitrectomy (PPV) combined with lensectomy in the treatment of glaucomatous eyes with extremely shallow anterior chamber and cataract. Prospective, nonrandomized and noncomparative case series study. Consecutive patients with secondary glaucoma, extremely shallow anterior chamber and cataract were recruited to have combined surgeries of 23-gauge transconjunctival pars plana vitrectomy and lensectomy. The main outcomes were best corrected visual acuity (BCVA), intraocular pressure (IOP), anterior chamber depth (ACD), number of anti-glaucoma medications and surgery-associated complications. Seventeen consecutive patients with secondary glaucoma, extremely shallow anterior chamber and cataract were recruited. The mean follow-up was 21.2 ± 8.8 months. Postoperatively, there was no significant improvement of BCVA (P = 0.25). The mean intraocular (IOP) decreased significantly from 43.14 ± 6.53 mmHg to 17.29 ± 1.80 mmHg (P shallow anterior chamber and cataract can be managed well with the combined surgeries of 23-gauge pars plana vitrectomy and lensectomy. The surgical procedure is an effective and safe method to resolve the pupillary block and deepen the anterior chamber.

  19. Catarata polar anterior piramidal deslocada para a câmara anterior causando edema de córnea: relato de caso Corneal edema caused by a pyramidal anterior polar cataract dislocated to the anterior chamber: case report

    Directory of Open Access Journals (Sweden)

    Ramon Coral Ghanem

    2004-08-01

    Full Text Available Cataratas polares anteriores piramidais são opacidades cônicas que se projetam para a câmara anterior a partir da cápsula anterior do cristalino. Na grande maioria dos pacientes a opacidade permanece aderida e estável durante toda a vida. O objetivo deste trabalho é documentar uma manifestação incomum desse tipo de catarata: a deiscência espontânea das pirâmides para a câmara anterior causando descompensação endotelial e edema corneal bilateral. Relatamos o caso de uma paciente feminina, de 66 anos, branca, que apresentava edema corneal localizado inferiormente no olho direito associado à lesão nodular branco-esclerótica compatível com a pirâmide anterior da catarata polar. O olho esquerdo apresentava edema corneal difuso intenso e presença de uma catarata polar anterior com a região piramidal deslocada para a câmara anterior. Sabe-se que a pirâmide anterior pode permanecer inabsorvida na câmara anterior por longo período, pois é composta de tecido colágeno denso. Isto causa perda endotelial progressiva e edema corneal e deve ser considerada indicação de remoção cirúrgica da catarata polar anterior e de seu fragmento. Ressalta-se, também, a importância do bom senso no julgamento das cataratas polares anteriores, considerando-se tamanho da opacidade, simetria das opacidades e componente cortical associado, na tentativa de se evitar ambliopia.Pyramidal anterior polar cataracts are conical opacities that project into the anterior chamber from the anterior capsule of the lens. In the vast majority of patients the opacity remains bound and stable throughout life. We report an unusual complication of this type of cataract: spontaneous dehiscence of the pyramids to the anterior chamber causing bilateral endothelial damage and corneal edema. 66-year-old white woman presented with inferior corneal edema in the right eye and diffuse corneal edema in the left eye. A white nodular lesion was observed in the inferior angle

  20. [Comparison of anterior chamber angle examination by UBM, SL-OCT and gonioscopy].

    Science.gov (United States)

    Liu, Rui-jue; Wang, Men; Xia, Wen-tao; Yu, Xiao-ying; Chen, Jie-min; Zhou, Shu; Peng, Shu-ya; Liu, Dong-mei

    2014-08-01

    To compare the agreement of anterior chamber angle examination by ultrasound biomicroscope (UBM), slit lamp optical coherence tomography (SL-OCT), and gonioscopy in angle recession and angle closure. The anterior chamber angle was measured with UBM, SL-OCT and gonioscopy in turns for temporal, nasal, superior and inferior quadrant in the same dark room. The results were compared with the agreement of the three methods in angle recession and angle closure by χ2 test and Kappa test. There were no statistically significant differences of the three methods in testing angle closure and angle recession (P>0.05). The consistency of UBM and gonioscopy was better (Kappa value of 0.882) than that of SL-OCT and gonioscopy (Kappa value of 0.624). When testing angle recession, UBM is better than SL-OCT with gonioscopy as the standard. When testing angle closure, UBM, SL-OCT and gonioscopy have good agreement.

  1. Anterior Chamber-Associated Immune Deviation (ACAID: An Acute Response to Ocular Insult Protects from Future Immune-Mediated Damage?

    Directory of Open Access Journals (Sweden)

    Robert E. Cone

    2009-01-01

    Full Text Available The “immune privilege” that inhibits immune defense mechanisms that could lead to damage to sensitive ocular tissue is based on the expression of immunosuppressive factors on ocular tissue and in ocular fluids. In addition to this environmental protection, the injection of antigen into the anterior chamber or infection in the anterior chamber induces a systemic suppression of potentially damaging cell-mediated and humoral responses to the antigen. Here we discuss evidence that suggests that Anterior Chamber-Associated Immune Deviation (ACAID a is initiated by an ocular response to moderate inflammation that leads to a systemic immunoregulatory response. Injection into the anterior chamber induces a rise in TNF-α and MCP-1 in aqueous humor and an infiltration of circulating F4/80 + monocytes that home to the iris. The induction of ACAID is dependent on this infiltration of circulating monocytes that eventually emigrate to the thymus and spleen where they induce regulatory T cells that inhibit the inductive or effector phases of a cell-mediated immune response. ACAID therefore protects the eye from the collateral damage of an immune response to infection by suppressing a future potentially damaging response to infection.

  2. Assessment of the anterior chamber parameters after laser iridotomy in primary angle close suspect using Pentacam and gonioscopy.

    Science.gov (United States)

    Esmaeili, Alireza; Barazandeh, Behzad; Ahmadi, Sina; Haghi, Alireza; Ahmadi Hosseini, Seyed Mahdi; Abolbashari, Fereshteh

    2013-01-01

    To evaluate the changes in the anterior segment parameters of the subjects with primary angle closure suspect (PACS) before and after laser iridotomy (LI) using the Pentacam and gonioscopy. Forty-eight eyes of 48 PACS were included. Anterior chamber angle (ACA), central anterior chamber depth (ACD), anterior chamber volume (ACV) and central corneal thickness (CCT) were recorded from the Pentacam before and one month after LI. ACA was graded according to Shaffer classification using the Goldmann gonioscopy. ACA increased significantly from 25.59±4.41 to 26.46±4.33 degrees (P=0.009) and ACV changed from 85.97±16.07mm(3) to 99.25±15.83mm(3) (P=0.000). The changes in ACD, CCT and intraocular pressure were non-significant (P>0.05). Gonioscopy showed significant widening of the Shaffer angle in 4 quadrants (P<0.001). Pentacam can serve as the objective instrument in assessing the efficacy of LI.

  3. Linguatula serrata in the anterior chamber of the eye

    Directory of Open Access Journals (Sweden)

    Muna Bhende

    2014-01-01

    Full Text Available We report a case of intraocular Linguatula in healthy young female who presented with a history of trivial trauma, dislocated lens, inflammation and secondary glaucoma. A mobile worm was seen in the anterior chamber. Pars plana lensectomy and vitrectomy was planned to remove both the cataractous lens and the parasite during which the worm disappeared from view but was later recovered from the cassette fluid. It was identified as the nymphal form of Linguatula serrata (tongue worm.

  4. Changes in ocular biometry and anterior chamber parameters after pharmacologic mydriasis and peripheral iridotomy in primary angle closure suspects

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Razeghinejad

    2016-07-01

    Conclusions: This study showed no change in the ocular biometric and anterior chamber parameters including iridocorneal angle after PI and/or pharmacologic mydriasis except for increments in anterior chamber volume. This factor has the potential to be used as a numerical proxy for iris position in evaluating and monitoring patients with primary angle closure suspects after PI.

  5. Effects of hemodialysis on corneal and anterior chamber morphometry and intraocular pressure in patients with end-stage renal disease

    Directory of Open Access Journals (Sweden)

    Mehtap Caglayan

    Full Text Available ABSTRACT Purpose: To evaluate the effects of hemodialysis (HD on corneal and anterior chamber morphometry, as well as intraocular pressure (IOP in patients with end-stage renal disease. Methods: Fifty right eyes were examined 30 minutes before and after HD. IOP was measured with a Goldmann applanation tonometer, and Ehlers' formula was used to calculate the corrected IOP values. The central corneal thickness (CCT, corneal volume (CV, keratometric values, anterior chamber depth (ACD, aqueous depth (AQD, anterior chamber volume (ACV, and anterior chamber angle (ACA in the nasal and temporal quadrants were measured with a Sirius anterior segment analysis system. Blood urea nitrogen levels, body mass, and systolic and diastolic arterial pressure were also measured before and after HD. Results: The mean age was 60.80 ± 13.38 (range: 35-80 years. The mean uncorrected and corrected IOP values decreased from 18.06 ± 3.91 and 18.31 ± 4.83 mmHg to 16.94 ± 3.87 and 16.95 ± 4.74 mmHg after HD, respectively (p=0.011 and p=0.003, respectively. The mean CCT decreased from 536.38 ± 24.73 to 533.18 ± 27.25 µm (p=0.002, and the mean CV decreased from 57.52 ± 3.15 to 55.68 ± 3.55 mm³ (p0.05 for all values. There were no significant correlations between the ocular and systemic parameters (p>0.05 for all correlations. Conclusions: Uncorrected IOP, corrected IOP, CCT, and CV values decreased after HD, whereas the anterior chamber morphometry values remained similar between the measurements performed before and after HD.

  6. Foreign Body Embedded in Anterior Chamber Angle

    Directory of Open Access Journals (Sweden)

    Shmuel Graffi

    2012-01-01

    Full Text Available Introduction. We present a case of a metallic foreign body embedded in the anterior chamber angle. After standing in close proximity to a construction worker breaking a tile, a 26-year-old woman using soft contact lens for the correction of mild myopia presented to emergency department for evaluation of a foreign body sensation of her right eye. Methods and Results. Diagnosis was confirmed by gonioscopic examination and a noncontrast CT scan of head and orbits. The foreign body was removed by an external approach without utilizing a magnet. The patient's final outcome was favorable. Discussion. The above is a rare clinical situation, which is impossible to detect on slit-lamp examination without a gonioscopic view. Proper imaging and a specific management are mandatory in order to achieve favorable outcome.

  7. Retrospective Study of Vitreous Tap Technique Using Needle Aspiration for Management of Shallow Anterior Chamber during Phacoemulsification

    Directory of Open Access Journals (Sweden)

    Ashraf Ahmed Nossair

    2017-01-01

    Full Text Available Purpose. To evaluate the technique of vitreous tap using needle aspiration for management of anterior chamber shallowness during phacoemulsification. Methods. A retrospective study included 26 eyes of 17 patients who underwent phacoemulsification in which vitreous tap was performed using a 27-gauge needle attached to a 5 ml syringe, inserted 3.5 mm from the limbus to aspirate 0.2 ml of liquefied vitreous if a cohesive (OVD failed to sufficiently deepen the anterior chamber. Results. Preoperative anterior chamber depth was 2.31 ± 0.26 mm, axial length was 21.7 ± 0.67 mm, lens thickness was 4.5 ± .19 mm, and cataract grade was 3.77 ± 1.4. Preoperative CDVA in LogMAR units was 0.98 ± 0.75. Coexisting angle closure glaucoma was present in 7 patients (26.92% preoperatively. Vitreous needle tap was successful in vitreous removal on the first attempt in 26 eyes (100%. Postoperative follow-up period was 22.88 ± 10.24 (4–39 months. The final postoperative CDVA in LogMAR units was 0.07 ± 0.1, while the final postoperative IOP was 16.54 ± 1.45 mmHg. No complications related to vitreous tap were noted. Conclusion. Vitreous needle tap is a simple, cost-effective, and safe technique for management of shallow anterior chamber in phacoemulsification.

  8. Gonioscopy and ultrasound biomicroscopy in the detection of angle closure in patients with shallow anterior chamber.

    Science.gov (United States)

    Cui, Shan-shan; Zou, Yan-hong; Li, Qian; Li, Li-na; Zhang, Ning; Liu, Xi-pu

    2014-12-01

    To assess the agreement between gonioscopy and ultrasound biomicroscopy (UBM) in detecting angle closure in Chinese patients with shallow anterior chamber. An observational comparative study of the two different examination methods was conducted. Patients with normal intraocular pressure and temporal peripheral anterior chamber depth less than a quarter of corneal thickness based on slit lamp examination were included in this study from December 2007 to May 2009 in the outpatient clinic of First Hospital of Tsinghua University. Gonioscopy was performed with a Goldman goniolens in dark room first and followed by full beam light and indentation. If the filtering trabecular meshwork was invisible or any peripheral anterior synechia was found, that quadrant of the angle was considered closed. UBM was first undertaken in a darkened room then repeated with normal room lighting. If iridotrabecular apposition was showed, that quadrant of the angle was considered closed. The status of angle closure of each quadrant with different methods was recorded. 85 eyes of 46 patients were included in this study. The agreement between gonioscopy and UBM was poor (Κgonioscopy and UBM was hardly affected by age or sex, while in dark condition, eyes with deeper anterior chamber (P=0.005) or plateau iris configuration tended to produce different results (P=0.075) in the 2 methods. Gonioscopy and UBM are both indispensable methods for detecting angle closure, neither can completely replace the other.

  9. Evaluation of white-to-white distance and anterior chamber depth measurements using the IOL Master, slit-lamp adapted optical coherence tomography and digital photographs in phakic eyes.

    Science.gov (United States)

    Wilczyński, Michał; Pośpiech-Zabierek, Aleksandra

    2015-01-01

    The accurate measurement of the anterior chamber internal diameter and depth is important in ophthalmic diagnosis and before some eye surgery procedures. The purpose of the study was to compare the white-to-white distance measurements performed using the IOL-Master and photography with internal anterior chamber diameter determined using slit lamp adapted optical coherence tomography in healthy eyes, and to compare anterior chamber depth measurements by IOL-Master and slit lamp adapted optical coherence tomography. The data were gathered prospectively from a non-randomized consecutive series of patients. The examined group consisted of 46 eyes of 39 patients. White-to-white was measured using IOL-Master and photographs of the eye were taken with a digital camera. Internal anterior chamber diameter was measured with slit-lamp adapted optical coherence tomography. Anterior chamber depth was measured using the IOL Master and slit-lamp adapted optical coherence tomography. Statistical analysis was performed using parametric tests. A Bland-Altman plot was drawn. White-to-white distance by the IOL Master was 11.8 +/- 0.40 mm, on photographs it was 11.29 +/- 0.58 mm and internal anterior chamber diameter by slit-lamp adapted optical coherence tomography was 11.34?0.54 mm. A significant difference was found between IOL-Master and slit-lamp adapted optical coherence tomography (pphotographs (pphotographs (p>0.05). All measurements were correlated (Spearman pphotographs. In order to obtain accurate measurements of the internal anterior chamber diameter and anterior chamber depth, a method involving direct visualization of intraocular structures should be used.

  10. Anterior Chamber Angle Measurements Using Schwalbe's Line with High Resolution Fourier-Domain Optical Coherence Tomography

    Science.gov (United States)

    Qin, Bing; Francis, Brian A.; Li, Yan; Tang, Maolong; Zhang, Xinbo; Jiang, Chunhui; Cleary, Catherine; Huang, David

    2012-01-01

    Purpose To use Fourier-domain optical coherence tomography (OCT) to measure the angle opening distance at Schwalbe's line (AOD-SL) and determine its value in anterior chamber angle assessment. Methods Horizontal scans of the nasal and temporal anterior chamber angles in glaucoma subjects were performed by 830 nm wavelength Fourier-domain OCT. Images were graded by two ophthalmologists who assessed the visibility of Schwalbe’s line (SL), anterior limbus (AL), scleral spur (SS), and angle recess (AR). AOD-SL was measured with computer calipers. SL was manually identified by the termination of the corneal endothelium. Gonioscopy was used to classify anterior chamber angles according to a modified Shaffer system. Spearman's rho analysis was performed to assess correlation between AOD-SL and modified Shaffer grade. A cut-off value of AOD-SL for diagnosing occludable angles (modified Shaffer grade ≤1) was determined by receiver operating characteristic (ROC) analyses. Results Thirty-five glaucoma subjects (65 eyes) were enrolled. SL, AL, AR, and SS were visible by OCT in 97.7%, 99.2%, 87.3%, and 80.8% of eyes, respectively. Nasal and temporal AOD-SLs were 322.6 ± 200.2 µm and 341.4 ± 197.4 µm, respectively. Correlation coefficients between AOD-SL and modified Shaffer grade were 0.80 (nasal) and 0.81 (temporal). The diagnostic cut-off value of AOD-SL for occludable angles was 290 µm. The areas under the ROC curve, sensitivity, specificity values were 0.90, 0.80, 0.87 (nasal) and 0.90, 0.85, 0.77 (temporal). Conclusions The measurement of AOD-SL by Fourier-domain OCT is highly correlated with gonioscopy and may be a useful noncontact method of assessing angle closure risk. PMID:22827999

  11. Effect of Anterior Chamber Depth on Intraocular Pressure after Uneventful Phacoemulsification Surgery in Nonglaucomatous Eyes with CataractEffect of Anterior Chamber Depth on Intraocular Pressure after Uneventful Phacoemulsification Surgery in Nonglaucomatous Eyes with CataractEffect of Anterior Chamber Depth on Intraocular Pressure after Uneventful Phacoemulsification Surgery in Nonglaucomatous Eyes with Cataract

    Directory of Open Access Journals (Sweden)

    Tansu Gönen

    2011-08-01

    Full Text Available Purpose: To evaluate the effect of preoperative anterior chamber depth (ACD on intraocular pressure (IOP after uneventful phacoemulsification and intraocular lens (IOL implantation in nonglaucomatous eyes. Material and Method: The medical records of fifty-five patients (30 male and 25 female were reviewed retrospectively. The patients who had undergone uneventful phacoemulsification and IOL implantation were divided into two groups according to the values of preoperative ACD: 30 eyes in group 1 (ACD≤3.27 mm and 25 eyes in group 2 (ACD>3.27 mm. IOP was measured using non-contact tonometer preoperatively and postoperatively (1 day, 1 week, 1 month, and 3 months. Results: Three months after phacoemulsification and IOL implantation, the mean IOP decreased 23.6% in group 1 and 13.7% in group 2. There was a statistically significant difference between the groups (p= 0.025. Discussion: The mean IOP decreases in eyes with shallow anterior chamber more than in normal eyes after uncomplicated phacoemulsification and IOL implantation. (Turk J Ophthalmol 2011; 41: 207-12

  12. A proposed simple method for measurement in the anterior chamber angle: biometric gonioscopy.

    Science.gov (United States)

    Congdon, N G; Spaeth, G L; Augsburger, J; Klancnik, J; Patel, K; Hunter, D G

    1999-11-01

    To design a system of gonioscopy that will allow greater interobserver reliability and more clearly defined screening cutoffs for angle closure than current systems while being simple to teach and technologically appropriate for use in rural Asia, where the prevalence of angle-closure glaucoma is highest. Clinic-based validation and interobserver reliability trial. Study 1: 21 patients 18 years of age and older recruited from a university-based specialty glaucoma clinic; study 2: 32 patients 18 years of age and older recruited from the same clinic. In study 1, all participants underwent conventional gonioscopy by an experienced observer (GLS) using the Spaeth system and in the same eye also underwent Scheimpflug photography, ultrasonographic measurement of anterior chamber depth and axial length, automatic refraction, and biometric gonioscopy with measurement of the distance from iris insertion to Schwalbe's line using a reticule based in the slit-lamp ocular. In study 2, all participants underwent both conventional gonioscopy and biometric gonioscopy by an experienced gonioscopist (NGC) and a medical student with no previous training in gonioscopy (JK). Study 1: The association between biometric gonioscopy and conventional gonioscopy, Scheimpflug photography, and other factors known to correlate with the configuration of the angle. Study 2: Interobserver agreement using biometric gonioscopy compared to that obtained with conventional gonioscopy. In study 1, there was an independent, monotonic, statistically significant relationship between biometric gonioscopy and both Spaeth angle (P = 0.001, t test) and Spaeth insertion (P = 0.008, t test) grades. Biometric gonioscopy correctly identified six of six patients with occludable angles according to Spaeth criteria. Biometric gonioscopic grade was also significantly associated with the anterior chamber angle as measured by Scheimpflug photography (P = 0.005, t test). In study 2, the intraclass correlation coefficient

  13. The clinical outcomes of surgical management of anterior chamber migration of a dexamethasone implant (Ozurdex®).

    Science.gov (United States)

    Kang, Hyunseung; Lee, Min Woo; Byeon, Suk Ho; Koh, Hyoung Jun; Lee, Sung Chul; Kim, Min

    2017-09-01

    Our purpose was to describe the clinical course, and individualized management approaches, of patients with migration of a dexamethasone implant into the anterior chamber. This was a retrospective review of four patients with seven episodes of anterior chamber migration of a dexamethasone implant. After 924 intravitreal dexamethasone injections, anterior migration of the implant occurred in four eyes of four patients (0.43%). All four eyes were pseudophakic: one eye had a posterior chamber intraocular lens in the capsular bag but in a post-laser posterior capsulotomy state, two eyes had a sulcus intraocular lens (IOL), and one eye had an iris-fixated retropupillary IOL. All eyes had a prior vitrectomy and no lens capsule. The time interval from injection to detection of the implant migration ranged from 2 to 6 weeks. Of the four eyes with corneal edema, only one eye required a corneal transplantation, although it was unclear whether the implant migration was the direct cause of the corneal decompensation because the patient had a history of bullous keratopathy resulting from an extended history of uveitis. All patients underwent surgical intervention: two patients with a repositioning procedure, and the other two patients with removal due to repeated episodes, although surgical removal was not always necessary to reverse the corneal complications. In our study, not all patients required surgical removal of the implants. Repositioning the implant back into the vitreous cavity may be considered as an option in cases involving the first episode with no significant corneal endothelial decompensation. Considering potential anterior segment complications and the loss of drug effectiveness together, an individualized approach is recommended to obtain the best treatment outcomes and to minimize the risk of corneal complications.

  14. Biometric gonioscopy and the effects of age, race, and sex on the anterior chamber angle

    Science.gov (United States)

    Congdon, N G; Foster, P J; Wamsley, S; Gutmark, J; Nolan, W; Seah, S K; Johnson, G J; Broman, A T

    2002-01-01

    Aim: To utilise a novel method for making measurements in the anterior chamber in order to compare the anterior chamber angles of people of European, African, and east Asian descent aged 40 years and over. Methods: A cross sectional study on 15 people of each sex from each decade from the 40s to the 70s, from each of three racial groups—black, white, and Chinese Singaporeans. Biometric gonioscopy (BG) utilises a slit lamp mounted reticule to make measurements from the apparent iris insertion to Schwalbe's line through a Goldmann one mirror goniolens. The main outcome measures were BG measurements of the anterior chamber angle as detailed above. Results: There was no significant difference in angle measurement between black, white, and Chinese races in this study. However, at younger ages people of Chinese race appeared to have deeper angles than white or black people, whereas the angles of older Chinese were significantly narrower (p = 0.004 for the difference in slope of BG by age between Chinese and both black and white people). Conclusion: The failure to detect a difference in angle measurements between these groups was surprising, given the much higher prevalence of angle closure among Chinese. It appears that the overall apparent similarity of BG means between Chinese and Western populations may mask very different trends with age. The apparently more rapid decline in angle width measurements with age among Chinese may be due to the higher prevalence of cataract or “creeping angle closure.” However, longitudinal inferences from cross sectional data are problematic, and this may represent a cohort phenomenon caused by the increasing prevalence of myopia in the younger Singaporean population. PMID:11801496

  15. Bile ascites in adults. Diagnosis using hepatobiliary scintigraphy and paracentesis

    International Nuclear Information System (INIS)

    Nagle, C.E.; Fink-Bennett, D.; Freitas, J.E.

    1985-01-01

    Hepatobiliary scintigraphy has been recognized as a useful diagnostic tool in detecting the presence and site of bile leaks. The authors report a case of bile ascites secondary to a postsurgical biliary leak, the scintigraphic findings in bile ascites, and the potential use of paracentesis, in combination with hepatobiliary scintigraphy, in confirming the presence of bile ascites and a bile leak

  16. Survival benefit of TIPS versus serial paracentesis in patients with refractory ascites: a single institution case-control propensity score analysis

    International Nuclear Information System (INIS)

    Gaba, R.C.; Parvinian, A.; Casadaban, L.C.; Couture, P.M.; Zivin, S.P.; Lakhoo, J.; Minocha, J.; Ray, C.E.; Knuttinen, M.G.; Bui, J.T.

    2015-01-01

    Aim: To compare the impact of covered stent-graft transjugular intrahepatic portosystemic shunt (TIPS) versus serial paracentesis on survival of patients with medically refractory ascites. Materials and methods: In this retrospective study, cirrhotic patients who underwent covered stent-graft TIPS for refractory ascites from 2003–2013 were compared with similar patients who underwent serial paracentesis during 2009–2013. Demographic and liver disease data, Model for End-Stage Liver Disease (MELD) scores, and survival outcomes were obtained from hospital electronic medical records and the social security death index. After propensity score weighting to match study group characteristics, survival outcomes were compared using Kaplan–Meier statistics with log-rank analysis. Results: Seventy TIPS (70% men, mean age 55.7 years, mean MELD 15.1) and 80 paracentesis (58% men, mean age 53.5 years, mean MELD 22.5) patients were compared. The TIPS haemodynamic success rate was 100% (mean portosystemic pressure gradient reduction 13 mmHg). Paracentesis patients underwent a mean of 7.9 procedures. After propensity score weighting to balance group features, TIPS patients showed a trend toward enhanced survival compared with paracentesis patients (median survival 1037 versus 262 days, p = 0.074). TIPS conferred a significant increase or trend toward improved survival compared with paracentesis at 1 (66% versus 44%, p = 0.018), 2 (56% versus 38%, p = 0.057), and 3 year (49% versus 32%, p = 0.077) time points. Thirty and 90 day mortality rates were not statistically increased by TIPS. Conclusion: Covered stent-graft TIPS improves intermediate- to long-term survival without significantly increasing short-term mortality of ascites patients, and suggests a greater potential role for TIPS in properly selected ascitic patients when medical management fails. - Highlights: • The survival benefit of TIPS for patients with refractory ascites remains unproven. • A case

  17. Moorfields technique of donor cornea mounting for femtosecond-assisted keratoplasty: use of viscoelastic in the artificial anterior chamber.

    Science.gov (United States)

    Iovieno, Alfonso; Chowdhury, Vivek; Stevens, Julian D; Maurino, Vincenzo

    2012-07-01

    Appropriate mounting and cutting of the donor sclero-corneal cap is often cumbersome during femtosecond laser-assisted keratoplasty. The authors describe a technique for donor cornea femtosecond laser cutting using ophthalmic viscoelastic devices. The donor sclero-corneal cap is mounted on the artificial anterior chamber using a dispersive ophthalmic viscoelastic device instead of saline solution. The chances of artificial anterior chamber pressure loss, inadequate applanation, and fluid leaks are consistently reduced with the use of dispersive ophthalmic viscoelastic devices. The speed of donor femtosecond laser cutting is increased. The viscosity and elasticity of dispersive ophthalmic viscoelastic devices greatly assist the procedure with regard to ease of applanation, corneal endothelium protection, and decreased distortion of the applanated cornea. Copyright 2012, SLACK Incorporated.

  18. The Injection of Air/Oxygen Bubble into the Anterior Chamber of Rabbits as a Treatment for Hyphema in Patients with Sickle Cell Disease

    Directory of Open Access Journals (Sweden)

    Emre Ayintap

    2014-01-01

    Full Text Available Purpose. To investigate the changes of partial oxygen pressure (PaO2 in aqueous humour after injecting air or oxygen bubble into the anterior chamber in sickle cell hyphema. Methods. Blood samples were taken from the same patient with sickle cell disease. Thirty-two rabbits were divided into 4 groups. In group 1 (n=8, there was no injection. Only blood injection constituted group 2 (n=8, both blood and air bubble injection constituted group 3 (n=8, and both blood and oxygen bubble injection constituted group 4 (n=8. Results. The PaO2 in the aqueous humour after 10 hours from the injections was 78.45 ± 9.9 mmHg (Mean ± SD for group 1, 73.97 ± 8.86 mmHg for group 2, 123.35 ± 13.6 mmHg for group 3, and 306.47 ± 16.5 mmHg for group 4. There was statistically significant difference between group 1 and group 2, when compared with group 3 and group 4. Conclusions. PaO2 in aqueous humour was increased after injecting air or oxygen bubble into the anterior chamber. We offer to leave an air bubble in the anterior chamber of patients with sickle cell hemoglobinopathies and hyphema undergoing an anterior chamber washout.

  19. Anterior chamber configuration in patients with glaucoma: MR gonioscopy evaluation with half-Fourier single-shot RARE sequence and microscopy coil.

    Science.gov (United States)

    Tanitame, Keizo; Sasaki, Ko; Sone, Takashi; Uyama, Shinji; Sumida, Masumi; Ichiki, Toshio; Ito, Katsuhide

    2008-10-01

    The purpose of the study was to determine the accuracy of half-Fourier single-shot rapid acquisition with relaxation enhancement high-spatial-resolution magnetic resonance (MR) imaging performed with a microscopy coil in the diagnosis of narrow anterior chamber angle in patients with glaucoma. Slit-lamp biomicroscopy served as the reference standard. The institutional review board approved this study, and written informed consent was obtained from the 20 recruited patients. There was excellent agreement between MR gonioscopy and slit-lamp biomicroscopy in the classification of anterior chamber angles as narrow or open (kappa = 0.89 [95% confidence interval: 0.69, 1.10]). MR gonioscopy has substantial potential as a technique used to evaluate glaucoma. (c) RSNA, 2008.

  20. Effect of laser peripheral iridotomy on anterior chamber angle anatomy in primary angle closure spectrum eyes

    Science.gov (United States)

    Kansara, Seema; Blieden, Lauren S.; Chuang, Alice Z.; Baker, Laura A.; Bell, Nicholas P.; Mankiewicz, Kimberly A.; Feldman, Robert M.

    2015-01-01

    Purpose To evaluate the change in trabecular-iris circumference volume (TICV) after laser peripheral iridotomy (LPI) in primary angle closure (PAC) spectrum eyes Patients and Methods Forty-two chronic PAC spectrum eyes from 24 patients were enrolled. Eyes with anterior chamber abnormalities affecting angle measurement were excluded. Intraocular pressure, slit lamp exam, and gonioscopy were recorded at each visit. Anterior segment optical coherence tomography (ASOCT) with 3D mode angle analysis scans were taken with the CASIA SS-1000 (Tomey Corp., Nagoya, Japan) before and after LPI. Forty-two pre-LPI ASOCT scans and 34 post-LPI ASOCT scans were analyzed using the Anterior Chamber Analysis and Interpretation (ACAI, Houston, TX) software. A mixed-effect model analysis was used to compare the trabecular-iris space area (TISA) changes among 4 quadrants, as well as to identify potential factors affecting TICV. Results There was a significant increase in all average angle parameters after LPI (TISA500, TISA750, TICV500, and TICV750). The magnitude of change in TISA500 in the superior angle was significantly less than the other angles. The changes in TICV500 and TICV750 were not associated with any demographic or ocular characteristics. Conclusion TICV is a useful parameter to quantitatively measure the effectiveness of LPI in the treatment of eyes with PAC spectrum disease. PMID:26066504

  1. Unilateral uveitis masquerade syndrome caused by diffuse large B-cell lymphoma diagnosed using multiparametric flow cytometry of the aqueous humor.

    Science.gov (United States)

    Monsalvo, Silvia; Serrano, Cristina; Prieto, Elena; Fernández-Sanz, Guillermo; Puente, Maria-Camino; Rodriguez-Pinilla, Maria; Garcia Raso, Aranzazu; Llamas, Pilar; Cordoba, Raul

    2017-07-01

    The uveitis masquerade syndromes (UMS) are a group of ocular diseases that may mimic chronic intraocular inflammation. Many malignant entities such as non-Hodgkin's lymphomas may masquerade as uveitis. We report a case of an HIV-positive patient with masquerade syndrome presenting unilateral uveitis. 45-year-old Caucasian man with a diagnosis of diffuse large B-cell lymphoma (DLBCL). The patient was diagnosed by a biopsy of an abdominal mass which showed fragments of gastric mucosa with diffuse growth of neoplastic cells. At diagnosis, the patient suffered from unilateral blurring of vision and a sudden decrease of left-eye visual acuity. A slit-lamp examination of the left eye revealed a diagnosis of anterior uveitis. The patient exhibited no signs of posterior uveitis. An anterior-chamber paracentesis was performed and analyzed by multiparameter flow cytometry (MFC), showing cells CD45, CD19, CD20, CD22, and CD38 positives, and moderate expression of CD10 with kappa light chain restriction, showing a monoclonal B-cell population. The patient received CHOP-R with intrathecal methotrexate followed by consolidation high dose methotrexate obtaining a complete response which is ongoing. Differential diagnosis between chronic uveitis and ocular lymphoma may be challenging. We advocate anterior-chamber paracentesis in cases of refractory uveitis in patients with hematologic malignancies. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  2. Comparison of the Results of Secondary Anterior Chamber and Secondary Scleral-Fixated Intraocular Lens Implantation in Complicated Phacoemulsification Cases

    Directory of Open Access Journals (Sweden)

    Nimet Yeşim Erçalık

    2014-03-01

    Full Text Available Objectives: To compare the visual prognosis and postoperative complication rates of secondary anterior chamber (AC IOL and scleralfixated (SF intraocular lenses (IOL after complicated phacoemulsification surgery. Materials and Methods: Thirty eyes of thirty patients were reviewed for this retrospective study. The patients with secondary AC IOL implantation formed group 1 (n=15, and the patients with secondary SF IOL implantation formed group 2 (n=15. Best-corrected visual acuity (BCVA with Snellen chart, biomicroscopic examination, intraocular pressure (IOP measurement with applanation tonometer, gonioscopy performed by Goldmann’s 3-mirror contact lens, and fundus examination were performed preoperatively in all patients. Results: There was no statistically significant difference in postoperative BCVA (p=0.492 and postoperative success (BCVA not changed or better postoperatively between the 2 groups (p=0.598. Postoperative success rate was 80% in group 1 and 93.7% in Group 2. The postoperative cylindrical power of the eyes did not differ significantly between the groups (p=0.220. The postoperative complications in group 1 were as follows: transient corneal edema in 5 eyes, transient IOP elevation in 2 eyes, postoperative fibrinous reaction in the anterior chamber in one eye, late-onset secondary glaucoma in one eye, hyphema in one eye, cystoid macular edema in one eye, vitreous prolapse into the anterior chamber in one eye, and IOL malposition in one eye. The postoperative complications in group 2 were as follows: transient corneal edema in 3 eyes, vitreous prolapse into the anterior chamber in 2 eyes, IOL malposition in 2 eyes, transient IOP elevation in one eye, and retinal detachment in one eye. Conclusion: In this study, both IOL types were observed to be preferable in cases without adequate capsular support following complicated cataract surgery. However, further studies with large numbers of patients are needed to define the best choice

  3. Non-invasive measurements of the dynamic changes in the ciliary muscle, crystalline lens morphology, and anterior chamber during accommodation with a high-resolution OCT.

    Science.gov (United States)

    Esteve-Taboada, José J; Domínguez-Vicent, Alberto; Monsálvez-Romín, Daniel; Del Águila-Carrasco, Antonio J; Montés-Micó, Robert

    2017-07-01

    The purpose of the study was to assess non-invasively the changes in the anterior chamber eye, crystalline lens morphology, and ciliary muscle during accommodation by means of an anterior chamber optical coherence tomographer (OCT), and correlate them with vergence. Twenty-five eyes of twenty-five healthy subjects, whose mean age was 29.9±7.1 years, were included and measured with an anterior chamber OCT. The central corneal thickness (CCT), anterior chamber depth (ACD), anterior crystalline lens radius of curvature (ALRC), crystalline lens thickness (CLT), and ciliary muscle area (CMA) were measured for each participant at 0, -1, -2, and -3 D of target vergence. A linear model was used to assess the correlation of each eye parameter with the vergence demand. The mean CCT showed no change for all the accommodative stimuli. The mean ACD and ALRC decreased with the vergence, about 4.5 and 30 % at -3 D, respectively. On the contrary, the CLT and CMA showed an opposite tendency, where the mean CLT was increased by 4.0 % and the mean CMA was done by 26% at -3 D. Statistical significant differences (p < 0.001) were obtained among all vergences for each eye metric, except for the CCT (p = 0.76). The ACD and ALRC decreased about 2 and 10 % per dioptre of accommodation, respectively; whereas the CLT and CMA increased about 2 and 9 %, respectively. These results add knowledge regarding the understanding of accommodation and give new perspectives for biomechanics and biometry.

  4. Evaluation of the anterior chamber angle in glaucoma: a report by the american academy of ophthalmology.

    Science.gov (United States)

    Smith, Scott D; Singh, Kuldev; Lin, Shan C; Chen, Philip P; Chen, Teresa C; Francis, Brian A; Jampel, Henry D

    2013-10-01

    To assess the published literature pertaining to the association between anterior segment imaging and gonioscopy and to determine whether such imaging aids in the diagnosis of primary angle closure (PAC). Literature searches of the PubMed and Cochrane Library databases were last conducted on July 6, 2011. The searches yielded 371 unique citations. Members of the Ophthalmic Technology Assessment Committee Glaucoma Panel reviewed the titles and abstracts of these articles and selected 134 of possible clinical significance for further review. The panel reviewed the full text of these articles and identified 79 studies meeting the inclusion criteria, for which the panel methodologist assigned a level of evidence based on a standardized grading scheme adopted by the American Academy of Ophthalmology. Three, 70, and 6 studies were rated as providing level I, II, and III evidence, respectively. Quantitative and qualitative parameters defined from ultrasound biomicroscopy (UBM), anterior segment optical coherence tomography (OCT), Scheimpflug photography, and the scanning peripheral anterior chamber depth analyzer (SPAC) demonstrate a strong association with the results of gonioscopy. There is substantial variability in the type of information obtained from each imaging method. Imaging of structures posterior to the iris is possible only with UBM. Direct imaging of the anterior chamber angle (ACA) is possible using UBM and OCT. The ability to acquire OCT images in a completely dark environment allows greater sensitivity in detecting eyes with appositional angle closure. Noncontact imaging using OCT, Scheimpflug photography, or SPAC makes these methods more attractive for large-scale PAC screening than contact imaging using UBM. Although there is evidence suggesting that anterior segment imaging provides useful information in the evaluation of PAC, none of these imaging methods provides sufficient information about the ACA anatomy to be considered a substitute for

  5. Preliminary study of a new intraocular method in the diagnosis and treatment of Propionibacterium acnes endophthalmitis following cataract extraction.

    Science.gov (United States)

    Owens, S L; Lam, S; Tessler, H H; Deutsch, T A

    1993-04-01

    Late endophthalmitis, due to Propionibacterium acnes, developed in three patients following uncomplicated extracapsular cataract extraction and posterior chamber intraocular lens (PC-IOL) insertion. Cultures from the capsular bag yielded P. acnes in all three. With topical anesthesia and through an anterior chamber paracentesis, culture specimens were taken from and clindamycin irrigated into the capsular bag. Filtered 100% oxygen was introduced into the anterior chamber in two; the third also received an injection of gentamicin and dexamethasone into the capsular bag. After treatment, two patients received oral antibiotics; one received hyperbaric oxygen therapy. Visual acuity was improved and inflammation reduced in all three. However, after treatment, ocular toxic effects due to clindamycin were suspected in one. This approach offers several clear advantages, including topical anesthesia, outpatient management, elimination of the need for vitrectomy, and retention of the intraocular lens (IOL).

  6. Cellular and Molecular Mechanisms of Anterior Chamber-Associated Immune Deviation (ACAID: What We Have Learned from Knockout Mice

    Directory of Open Access Journals (Sweden)

    Julie Vendomèle

    2017-11-01

    Full Text Available Anterior chamber-associated immune deviation (ACAID is a well-known phenomenon that can occur after an antigen is introduced without any danger signal into the anterior chamber of a murine eye. It is reported to lead to an antigen-specific immune deviation throughout the body. Despite the relatively little evidence of this phenomenon in humans, it has been suggested as a potential prophylactic strategy in allograft rejections and in several autoimmune diseases. Cellular and molecular mechanisms of ACAID have been explored in different murine models mainly as proofs of concept, first by direct analyses of immune components in normal immunocompetent settings and by cell transfer experiments. Later, use of knockout (KO mice has helped considerably to decipher ACAID mechanisms. However, several factors raise questions about the reliability and validity of studies using KO murine models. This mini-review summarizes results obtained with KO mice and discusses their advantages, their potential weaknesses, and their potential methods for further progress.

  7. Age, Gender, Biometry, Refractive Error, and the Anterior Chamber Angle among Alaskan Eskimos

    Science.gov (United States)

    Wojciechowski, Robert; Congdon, Nathan; Anninger, William; Broman, Aimee Teo

    2011-01-01

    Background The prevalence of angle-closure glaucoma (ACG) is greater for Eskimos/Inuit than it is for any other ethnic group in the world. Although it has been suggested that this prevalence may be due to a population tendency toward shallower anterior chamber angles, available evidence for other populations such as Chinese with high rates of ACG has not consistently demonstrated such a tendency. Methods A reticule, slit-lamp, and standard Goldmann one-mirror goniolens were used to make measurements in the anterior chamber (AC) angle according to a previously reported protocol for biometric gonioscopy (BG) (Ophthalmology 1999;106:2161–7). Measurements were made in all four quadrants of one eye among 133 phakic Alaskan Eskimos aged 40 years and older. Automatic refraction, dilated examination of the anterior segment and optic nerve, and A-scan measurements of AC depth, lens thickness, and axial length were also carried out for all subjects. Results Both central and peripheral AC measurements for the Eskimo subjects were significantly lower than those previously reported by us for Chinese, blacks, and whites under the identical protocol. Eskimos also seemed to have somewhat more hyperopia. There were no differences in biometric measurements between men and women in this Eskimo population. Angle measurements by BG seemed to decline more rapidly over life among Eskimos and Chinese than blacks or whites. Although there was a significant apparent decrease in AC depth, increase in lens thickness, and increase in hyperopia with age among Eskimos, all of these trends seemed to reverse in the seventh decade and beyond. Conclusions Eskimos do seem to have shallower ACs than do other racial groups. Measurements of the AC angle seem to decline more rapidly over life among Eskimos than among blacks or whites, a phenomenon also observed by us among Chinese, another group with high ACG prevalence. This apparent more rapid decline may be due to a cohort effect with higher

  8. Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles.

    Science.gov (United States)

    Grewal, D S; Brar, G S; Jain, R; Grewal, S P S

    2011-05-01

    To compare the performance of anterior chamber volume (ACV) and anterior chamber depth (ACD) obtained using Scheimpflug imaging with angle opening distance (AOD500) and trabecular-iris space area (TISA500) obtained using spectral domain anterior segment optical coherence tomography (SD-ASOCT) in detecting narrow angles classified using gonioscopy. In this prospective, cross-sectional observational study, 265 eyes of 265 consecutive patients underwent sequential Scheimpflug imaging, SD-ASOCT imaging, and gonioscopy. Correlations between gonioscopy grading, ACV, ACD, AOD500, and TISA500 were evaluated. Area under receiver operating characteristic curve (AUC), sensitivity, specificity, and likelihood ratios (LRs) were calculated to assess the performance of ACV, ACD, AOD500, and TISA500 in detecting narrow angles (defined as Shaffer grade ≤1 in all quadrants). SD-ASOCT images were obtained at the nasal and temporal quadrants only. Twenty-eight eyes (10.6%) were classified as narrow angles on gonioscopy. ACV correlated with gonioscopy grading (P<0.001) for temporal (r=0.204), superior (r=0.251), nasal (r=0.213), and inferior (r=0.236) quadrants. ACV correlated with TISA500 for nasal (r=0.135, P=0.029) and temporal (P=0.160, P=0.009) quadrants and also with AOD500 for nasal (r=0.498, P<0.001) and temporal (r=0.517, P<0.001) quadrants. For detection of narrow angles, ACV (AUC=0.935; 95% confidence interval (CI) =0.898-0.961) performed similar to ACD (AUC=0.88, P=0.06) and significantly better than AOD500 nasal (AUC=0.761, P=0.001), AOD500 temporal (AUC=0.808, P<0.001), TISA500 nasal (AUC=0.756, P<0.001), and TISA500 temporal (AUC=0.738, P<0.001). Using a cutoff of 113 mm(3), ACV had 90% sensitivity and 88% specificity for detecting narrow angles. Positive and negative LRs for ACV were 8.63 (95% CI=7.4-10.0) and 0.11 (95% CI=0.03-0.4), respectively. ACV measurements using Scheimpflug imaging outperformed AOD500 and TISA500 using SD-ASOCT for detecting narrow angles.

  9. Diseño e implementación de un modelo de enseñanza en ambiente simulado de paracentesis abdominal

    Directory of Open Access Journals (Sweden)

    Thomas Uslar

    2017-08-01

    Full Text Available El aprendizaje de los estudiantes de Medicina de Pregrado en ambiente simulado constituye una alternativa en la obtención de competencias técnicas y no técnicas. Objetivo: Desarrollar un fantoma e implementar un taller modular de entrenamiento de paracentesis abdominal en ambiente simulado para estudiantes de Medicina. Métodos: Se diseñaron y desarrollaron modelos para la realización de paracentesis abdominal en la Escuela de Diseño de la Pontificia Universidad Católica de Chile (PUC y se implementó un taller para alumnos de 4to año de Medicina de la PUC, utilizando un enfoque constructivista, sesiones de entrenamiento simulado con debriefing basadas en el modelo plus-delta y evaluación pre y post-procedimiento siguiendo los principios de evaluación para el aprendizaje. Resultados: Se desarrollaron 3 prototipos hasta llegar a un modelo definitivo de alta fidelidad basado en la percepción de 20 expertos. 237 alumnos asistieron a un taller de paracentesis abdominal en el Centro de Cirugía Experimental y Simulación Universidad Católica (UC. Este consistió en una actividad práctica grupal (7-8 alumnos por sesión que incluyó: una evaluación pre-sesión, un vídeo instruccional, una demostración en tiempo real en el fantoma por parte de un docente, la realización guiada del procedimiento por parte de los alumnos, debriefing y cierre de la sesión. Conclusiones: Un modelo de enseñanza en ambiente simulado es posible de ser diseñado e implementado exitosamente en un centro educacional para estudiantes de Medicina de Pregrado. Este taller de paracentesis permite entrenar a los alumnos en la realización de paracentesis abdominal en un ambiente seguro para los alumnos y pacientes y puede ser implementado a bajo costo en otros centros o instituciones.

  10. Clinical outcomes of Ahmed glaucoma valve in anterior chamber versus ciliary sulcus.

    Science.gov (United States)

    Bayer, A; Önol, M

    2017-04-01

    PurposeTo evaluate the outcomes of Ahmed glaucoma valve (AGV) tube insertion through the anterior chamber angle (ACA) or through the ciliary sulcus (CS).Patients and methodsIn this case-control study, we retrospectively reviewed the charts of consecutive glaucoma patients who had undergone AGV implantation either through the ACA or the CS between March 2009 and December 2014. The main outcome measures were intraocular pressure (IOP), number of glaucoma medications prescribed, best corrected visual acuity (BCVA), glaucoma type, success rate, complications, and survival ratios. Statistical analysis was carried out using SPSS.ResultsThere were 68 eyes in the ACA group and 35 eyes in the CS group. There were no significant differences between the groups for age, sex, laterality, IOP, preoperative glaucoma medication number, BCVA or glaucoma type (P>0.05). The postoperative follow-up period was 27.2±16.5 months and 30.2±17.7 months for the ACA and the CS groups (P=0.28); IOP values were significantly reduced at the last visit to 16.4±7.2 mm Hg and 14.4±6.8 mm Hg. The difference in the last-visit IOP between the groups was not significant (P=0.06), but the IOP reduction ratio was higher in the CS group (P=0.03). There was no significant difference in the number of postoperative medications (P=0.18). Postoperative complications were similar, but the incidence of flat anterior chamber was higher in the ACA group (P=0.05).ConclusionsThe use of an AGV can control IOP in the majority of cases whether placed in the ACA or the CS. The IOP reduction ratio seemed to be higher in the CS group.

  11. Loa loa in the anterior chamber of the eye: A case report

    Directory of Open Access Journals (Sweden)

    Barua P

    2005-01-01

    Full Text Available An unusual case of loiasis from Assam is reported here. Loa loa is a subcutaneous filarial parasite of man and is transmitted to humans by chrysops flies. The patient presented with foreign body sensation and visual disturbances of the right eye. Examination revealed a white coiled structure in the cornea.. Routine blood and other investigations were within normal limits. A live adult worm was extracted and identity was confirmed by microscopy to be Loa loa. Patient was treated with diethylcarbamazine and steroid. We found this case interesting as the worm was present in the anterior chamber - an unusual site and there were no other positive findings besides the lone worm.

  12. Ocular Toxicity after High-Dose Cefuroxime Injection into the Anterior Chamber

    Directory of Open Access Journals (Sweden)

    Harun Çakmak

    2016-08-01

    Full Text Available Cephalosporins are beta-lactam antibiotics and, like penicillin derivatives, they show bacteriostatic effect by disrupting bacterial cell wall synthesis. Cefuroxime is a second generation cephalosporin and the use of intracameral cefuroxime after cataract surgery has been widely used in the endophthalmitis prophylaxis. A 78-year-old male patient was operated for cataracts in both eyes about 8 years ago. Ocular trauma has occurred in the left eye nine months ago. Vitrectomy surgery combined with intraocular lens extraction was performed and the patient was left aphakic. Secondary intraocular lens implantation was performed. In this paper, we present postoperative ocular findings in a patient who was given cefuroxime into the anterior chamber 2.5 times higher than the recommended dose (25 mg/ml after secondary intraocular lens implantation.

  13. CD4+PD-1+T Cells Acting as Regulatory Cells during the Induction of Anterior Chamber-Associated Immune Devation

    NARCIS (Netherlands)

    Meng, Q.; Yang, P.; Li, B.; Zhou, H.; Huang, X.; Zhu, L.; Ren, Y.; Kijlstra, A.

    2006-01-01

    To study the expression and functional characteristics of programmed death-1 (PD-1) and its ligands in the spleens of mice undergoing anterior chamber-associated immune deviation (ACAID). METHODS: ACAID was induced in BALB/c mice by intracameral injection of ovalbumin (OVA). The expression of PD-1

  14. Effect of altered eating habits and periods during Ramadan fasting on intraocular pressure, tear secretion, corneal and anterior chamber parameters

    NARCIS (Netherlands)

    Kerimoglu, H.; Ozturk, B.; Gunduz, K.; Bozkurt, B.; Kamis, U.; Okka, M.

    Purpose To determine whether altered eating habits and periods, especially the pre-dawn meal, during Ramadan fasting have any significant effect on intraocular pressure (IOP), tear secretion, corneal and anterior chamber parameters. Methods IOP, basal tear secretion (BTS), reflex tear secretion

  15. Point-of-service, quantitative analysis of ascorbic acid in aqueous humor for evaluating anterior globe integrity

    Science.gov (United States)

    Gartia, Manas R.; Misra, Santosh K.; Ye, Mao; Schwartz-Duval, Aaron; Plucinski, Lisa; Zhou, Xiangfei; Kellner, David; Labriola, Leanne T.; Pan, Dipanjan

    2015-11-01

    Limited training, high cost, and low equipment mobility leads to inaccuracies in decision making and is concerning with serious ocular injuries such as suspected ruptured globe or post-operative infections. Here, we present a novel point-of-service (POS) quantitative ascorbic acid (AA) assay with use of the OcuCheck Biosensor. The present work describes the development and clinical testing of the paper-based biosensor that measures the changes in electrical resistance of the enzyme-plated interdigitated electrodes to quantify the level of AA present in ocular fluid. We have demonstrated the proof-of-concept of the biosensor testing 16 clinical samples collected from aqueous humor of patients undergoing therapeutic anterior chamber paracentesis. Comparing with gold standard colorimetric assay for AA concentration, OcuCheck showed accuracy of >80%, sensitivity of >88% and specificity of >71%. At present, there are no FDA-approved POS tests that can directly measures AA concentration levels in ocular fluid. We envisage that the device can be realized as a handheld, battery powered instrument that will have high impact on glaucoma care and point-of-care diagnostics of penetrating ocular globe injuries.

  16. Primary anterior chamber intraocular lens for the treatment of severe crystalline lens subluxation.

    Science.gov (United States)

    Hoffman, Richard S; Fine, I Howard; Packer, Mark

    2009-10-01

    Subluxated cataractous and clear lenses are commonly treated by limbal or pars plana lensectomy followed by primary or secondary intraocular lens (IOL) implantation. Adjunctive capsular prosthetic devices have facilitated lens removal and IOL centration in these challenging cases but have also added complexity and potential complications to the procedure. Although crystalline lens extraction may be required to clear the visual axis in mild to moderate lens subluxations, we propose insertion of a primary anterior chamber IOL without lens extraction in severe subluxations when the eye is optically aphakic or can be made functionally aphakic following neodymium:YAG laser zonulysis. Two cases demonstrating this approach are presented.

  17. Anterior chamber angle imaging with swept-source optical coherence tomography: measuring peripheral anterior synechia in glaucoma.

    Science.gov (United States)

    Lai, Isabel; Mak, Heather; Lai, Gilda; Yu, Marco; Lam, Dennis S C; Leung, Christopher K S

    2013-06-01

    To investigate the use of swept-source optical coherence tomography (OCT) for measuring the area and degree of peripheral anterior synechia (PAS) involvement in patients with angle-closure glaucoma. Cross-sectional study. Twenty-three eyes with PAS (detected by indentation gonioscopy) from 20 patients with angle-closure glaucoma (20 eyes had primary angle-closure glaucoma and 3 eyes had angle-closure glaucoma secondary to chronic anterior uveitis [n = 2] and Axenfeld-Rieger syndrome [n = 1]). The anterior chamber angles were evaluated with indentation gonioscopy and imaged by swept-source OCT (Casia OCT, Tomey, Nagoya, Japan) in room light and in the dark using the "angle analysis" protocol, which was composed of 128 radial B-scans each with 512 A-scans (16-mm scan length). The area and degree of PAS involvement were measured in each eye after manual detection of the scleral spur and the anterior irido-angle adhesion by 2 masked observers. The interobserver variability of the PAS measurements was calculated. The agreement of PAS assessment by gonioscopy and OCT, the area and the degree of PAS involvement, and the intraclass correlation coefficient (ICC) of interobserver PAS measurements. The area of PAS (mean ± standard deviation) was 20.8 ± 16.9 mm(2) (range, 3.9-74.9 mm(2)), and the degree of PAS involvement was 186.5 ± 79.9 degrees (range, 42-314 degrees). There was no difference in the area of PAS (P = 0.90) and the degree of PAS involvement (P = 0.95) between images obtained in room light and in the dark. The interobserver ICCs were 0.99 (95% confidence interval [CI], 0.98-1.00) for the area of PAS and 0.99 (95% CI, 0.97-1.00) for the degree of PAS involvement. There was good agreement of PAS assessment between gonioscopy and OCT images (kappa = 0.79; 95% CI, 0.67-0.91). Swept-source OCT allows visualization and reproducible measurements of the area and degree of PAS involvement, providing a new paradigm for evaluation of PAS progression and risk assessment

  18. Modeling the drug transport in the anterior segment of the eye.

    Science.gov (United States)

    Avtar, Ram; Tandon, Deepti

    2008-10-02

    The aim of the present work is the development of a simple mathematical model for the time course concentration profile of topically administered drugs in the anterior chamber aqueous humor and investigation of the effects of various model parameters on the aqueous humor concentration of lipophilic and hydrophilic drugs. A simple pharmacokinetic model for the transient drug transport in the anterior segment has been developed by using the conservation of mass in the precorneal tear film, Fick's law of diffusion and Michaelis-Menten kinetics of drug metabolism in cornea, and the conservation of mass in the anterior chamber. An analytical solution describing the drug concentration in the anterior chamber has been obtained. The model predicts that an increase in the drug metabolic (consumption) rate in the corneal epithelium reduces the drug concentration in the anterior chamber for both lipophilic and hydrophilic molecules. A decrease in the clearance rate and distribution volume of the drug in the anterior chamber raises the aqueous humor concentration significantly. It is also observed that decay rate of drug concentration in the anterior chamber is higher for lipophilic molecules than that for hydrophilic molecules. The bioavailability of drugs applied topically to the eye may be improved by a rise in the precorneal tear volume, diffusion coefficient in corneal epithelium and distribution coefficient across the endothelium anterior chamber interface, and by reducing the drug metabolism, drug clearance rate and distribution volume in anterior chamber.

  19. Transient anterior subcapsular vacuolar change of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation.

    Science.gov (United States)

    Chung, Jin Kwon; Shin, Jin Hee; Lee, Sung Jin

    2013-10-25

    We present two cases of transient vacuolar changes in the anterior subcapsular space of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation. Implantable collamer lenses (ICL) were implanted in healthy myopic patients. Vacuolar changes developed just after the irrigating procedure through the narrow space between the ICL and the crystalline lens. Slit-lamp examinations and spectral domain optical coherence tomography showed bleb-like lesions in the anterior subcapsular space of one eye in each case, though the lesions gradually improved without visual deterioration. Consequently, the lesions turned into a few anterior subcapsular small faint opacities. Direct irrigation of the narrow space confined by the ICL and the crystalline lens is at risk for the development of vacuolar changes in the crystalline lens. The observed spontaneous reversal indicates that surgeons should not rush to surgical intervention but rather opt for close follow over several weeks.

  20. Correlation between intraocular pressure and the biometric structure of the anterior chamber in patients of chronic renal failure with hemodialysis

    Directory of Open Access Journals (Sweden)

    Zhi-Ying Yu

    2017-02-01

    Full Text Available AIM: To investigate the correlation between intraocular pressure(IOPchanges pre- and post-hemodialysis(HDand the biometric structure of the anterior chamber in patients of chronic renal failure. METHODS: Fifty-two patients(take right eye as study onewith hemodialysis that were diagnosed with chronic renal failure by nephrology in our hospital from January 2015 to December 2015 were collected. Fifty-two eyes were divided into four groups based on Shaffer classification combined with ultrasound biomicroscopy(UBMand gonioscopy manifestations: wide angle group, narrow angle group, extremely narrow group and close angle group. Venous blood was collected to get plasma colloid osmotic pressure before HD and within 60s after HD. IOP was measured with rebound intraocular pressure gauge in a supine positon approximately 30min before starting HD, 2h after HD begin and approximately 30min after HD ending. Approximately 30min before and after HD, central corneal thickness was measured with corneal endothelial cell counter, central anterior chamber depth and lens thickness were taken by A scan, angle opening distance, trabecular iris angle, iris thickness and ciliary body thickness were measured by UBM. RESULTS: Plasma osmotic pressure reduced after HD, the difference was statistically significant(t=3.04, PF=41.69, PPPF=6.44, PPt=2.61, PCONCLUSION: The influence of hemodialysis on IOP is related to the biometric structure of the anterior chamber. And extremely narrow angle is risk factor of elevated IOP during hemodialysis, narrow angle may be a risk factor. While patients with wide angle is relatively safe. We suggest to take ocular examination as early as possible for patients with hemodialysis, and focus on patients with narrow angle.

  1. [Contribution of confocal microscopy and anterior chamber OCT to the study of corneal endothelial pathologies].

    Science.gov (United States)

    Fayol, N; Labbé, A; Dupont-Monod, S; Dupas, B; Baudouin, C

    2007-04-01

    To describe the appearance of various endothelial diseases with in vivo confocal microscopy and anterior chamber optical coherence tomography (AC OCT). In this study, ten patients with five different corneal endothelial pathologies were evaluated. Three patients had cornea guttata, three had corneal endothelial precipitates, two had irido-corneo-endothelial (ICE) syndrome, one had endothelial folds, and one had breaks in the Descemet membrane. All patients had bilateral ophthalmologic examinations, in vivo confocal microscopy, and AC OCT analysis. In cases of cornea guttata, AC OCT showed a finely embossed line corresponding to the empty intercellular cavities found with in vivo confocal microscopy. Corneal endothelium precipitates had the aspect of round formations suspended with the endothelium. Iris atrophy and irido-corneal synechiae resulting from ICE syndrome were precisely visualized with the AC OCT. High-resolution images of the anterior segment could be obtained using the AC OCT. Associated with in vivo confocal microscopy, these two new imaging techniques provide a precise evaluation of endothelial pathologies.

  2. [Supportive care for malignant ascites in palliative phase: Place of paracentesis and diuretics].

    Science.gov (United States)

    Gamblin, Vincent; Da Silva, Arlette; Villet, Stéphanie; El Hajbi, Farid

    2015-11-01

    Malignant ascites, occurring in advanced stages of cancer, is linked with poor prognosis and can cause invalidating symptoms. Physiopathological mechanisms of ascites formation are complex and have yet to be fully elucidated. In most cases, ascites is due to peritoneal carcinomatosis in which vascular permeability is enhanced by VEGF production while lymphatic drainage decreases. Ascites can also be secondary to portal hypertension, for example in case of multiple liver metastases, or due to lymphatic obstruction. While paracentesis and diuretics are commonly used, their efficiency has never been compared in a randomized controlled study. Paracentesis brings immediate but temporary relief in over 90% of cases, and implies multiple hospitalizations. Literature reports ascites control by aldosterone alone or in association with furosemide. But, available data is controversial, and there is no predictive factor to identify patients that respond to diuretic treatment. The indication of diuretic treatment is left to the appreciation of physicians. Existing recommendations are old, and practices influenced by results obtained in non-neoplastic ascites. Additional evidences are required before guidelines can be established for the palliative management of malignant ascites. Copyright © 2015 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.

  3. [Experimental hypertony caused by obstruction of the anterior chamber angle ab interno (author's transl)].

    Science.gov (United States)

    Maguritsas, N; Vikas, C; Theodossiadis, G; Vergados, I; Velissaropoulos, P

    1976-07-01

    In 30 rabbits, separated into 3 groups (A, B and C), the entire area (A), three quarters (B) half of the anterior chamber angle (C) was experimentally obstructed by means of a homologous scleral graft. In groups A and B a statistically significant change of the intraocular pressure and of the cornea diameter was shown as compared with the control eye and group C. This change is due to the obstructed area of the angle. The increased intraocular pressure lasted for some months. The graft was well tolerated by the tissue of the angle and the obstruction of the angle was total, as was confirmed by means of the histological preparations.

  4. Nonpenetrating glaucoma surgery with goniosynechiolysis ab interno: a surgical technique.

    Science.gov (United States)

    Mirshahi, A; Scharioth, G B

    2009-01-01

    To present a surgical technique for treatment of peripheral anterior synechiae (PAS or goniosynechiae) at the operative field during nonpenetrating glaucoma surgery. After usual preparation of a superficial and a deep scleral flap with externalization of the Schlemm's canal and peeling the juxtacanalicular trabecular meshwork, the goniosynechia is transected by a spatula introduced to the anterior chamber through a paracentesis. A Descemet's window provides full visual control at the peripheral cornea at the basis of the superficial scleral flap. With this surgical technique, selective treatment of goniosynechiae is possible exactly at the area where creation of low outflow resistance is intended by the surgeon during nonpenetrating glaucoma surgery. This technique enables the surgeon to perform nonpenetrating glaucoma surgery even in the presence of peripheral anterior synechiae.

  5. Comparison of slitlamp optical coherence tomography and scanning peripheral anterior chamber depth analyzer to evaluate angle closure in Asian eyes.

    Science.gov (United States)

    Wong, Hon-Tym; Chua, Jocelyn L L; Sakata, Lisandro M; Wong, Melissa H Y; Aung, Han T; Aung, Tin

    2009-05-01

    To evaluate the effectiveness of slitlamp optical coherence tomography (SL-OCT) and Scanning Peripheral Anterior Chamber depth analyzer (SPAC) in detecting angle closure, using gonioscopy as the reference standard. A total of 153 subjects underwent gonioscopy, SL-OCT, and SPAC. The anterior chamber angle (ACA) was classified as closed on gonioscopy if the posterior trabecular meshwork could not be seen; with SL-OCT, closure was determined by contact between the iris and angle wall anterior to the scleral spur; and with SPAC by a numerical grade of 5 or fewer and/or a categorical grade of suspect or potential. A closed ACA was identified in 51 eyes with gonioscopy, 86 eyes with SL-OCT, and 61 eyes with SPAC (gonioscopy vs SL-OCT, P gonioscopy vs SPAC, P = .10; SL-OCT vs SPAC, P gonioscopy, SL-OCT detected a closed ACA in 43, whereas SPAC identified 41 (P = .79). An open angle in all 4 quadrants was observed in 102 eyes with gonioscopy, but SL-OCT and SPAC identified 43 and 20 of these eyes, respectively, as having angle closure. The overall sensitivity and specificity for SL-OCT were 84% and 58% vs 80% and 80% for SPAC. Using gonioscopy as the reference, SL-OCT and SPAC showed good sensitivity for detecting eyes at risk of angle closure.

  6. A methodology based on the "anterior chamber of rabbit eyes" model for noninvasively determining the biocompatibility of biomaterials in an immune privileged site.

    Science.gov (United States)

    Lu, Pei-Lin; Lai, Jui-Yang; Tabata, Yasuhiko; Hsiue, Ging-Ho

    2008-07-01

    In this study, a novel methodology based on the anterior chamber of rabbit eyes model was developed to evaluate the in vivo biocompatibility of biomaterials in an immune privileged site. The 7-mm-diameter membrane implants made from either a biological tissue material (amniotic membrane, AM group) or a biomedical polymeric material (gelatin, GM group) were inserted in rabbit anterior chamber for 36 months and characterized by biomicroscopic examinations, intraocular pressure measurements, and corneal thickness measurements. The noninvasive ophthalmic parameters were scored to provide a quantitative grading system. In this animal model, both AM and GM implants were visible in an ocular immune privileged site during clinical observations. The implants of the AM group appeared as soft tissue patches and have undergone a slow dissolution process resulting in a partial reduction of their size. Additionally, the AM implants did not induce any foreign body reaction or change in ocular tissue response for the studied period. By contrast, in the GM groups, significant corneal edema, elevated intraocular pressure, and increased corneal thickness were noted in the early postoperative phase (within 3 days), but resolved rapidly with in vivo dissolution of the gelatin. The results from the ocular grading system showed that both implants had good long-term biocompatibility in an ocular immune privileged site for up to 3 years. It is concluded that the anterior chamber of rabbit eyes model is an efficient method for noninvasively determining the immune privileged tissue/biomaterial interactions. (c) 2007 Wiley Periodicals, Inc.

  7. Study of Anterior Chamber Aqueous Tube Shunt by Fourier-Domain Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Chunhui Jiang

    2012-01-01

    Full Text Available Purpose. This cross-sectional, observational study used Fourier-domain optical coherence tomography (OCT to examine the position, patency, and the interior entrance site of anterior chamber (AC aqueous tube shunts. Methods. The OCT, slitlamp biomicroscopy, and gonioscopy findings of 23 eyes of 18 patients with AC shunts were collected and compared. Results. OCT images demonstrated the shunt position and patency in all 23 eyes, and the details of the AC entrance in 16 eyes. The position of the tube varied, with the majority (14/23 on the surface of the iris. The exact position of the AC entrance relative to Schwalbe’s line (SL could be determined in 9 eyes (posterior to SL in 7 eyes, anterior in 2 eyes. At the AC entrance, growth of fibrous scar tissue was present between the tube and the corneal endothelium in all 16 eyes in which the entrance could be clearly visualized. It’s a new finding that could not be visualized by slitlamp examination or lower resolution OCT. Conclusion. Compared to slitlamp examination, Fourier-domain OCT of AC tube shunts provided more detailed anatomic information regarding the insertion level relative to SL, scar tissue between the tube and the corneal endothelium, and patency of the tube opening.

  8. Capsid Mutated Adeno-Associated Virus Delivered to the Anterior Chamber Results in Efficient Transduction of Trabecular Meshwork in Mouse and Rat.

    Directory of Open Access Journals (Sweden)

    Barbara Bogner

    Full Text Available Adeno associated virus (AAV is well known for its ability to deliver transgenes to retina and to mediate improvements in animal models and patients with inherited retinal disease. Although the field is less advanced, there is growing interest in AAV's ability to target cells of the anterior segment. The purpose of our study was to fully articulate a reliable and reproducible method for injecting the anterior chamber (AC of mice and rats and to investigate the transduction profiles of AAV2- and AAV8-based capsid mutants containing self-complementary (sc genomes in the anterior segment of the eye.AC injections were performed in C57BL/6 mice and Sprague Dawley rats. The cornea was punctured anterior of the iridocorneal angle. To seal the puncture site and to prevent reflux an air bubble was created in the AC. scAAVs expressing GFP were injected and transduction was evaluated by immunohistochemistry. Both parent serotype and capsid modifications affected expression. scAAV2- based vectors mediated efficient GFP-signal in the corneal endothelium, ciliary non-pigmented epithelium (NPE, iris and chamber angle including trabecular meshwork, with scAAV2(Y444F and scAAV2(triple being the most efficient.This is the first study to semi quantitatively evaluate transduction of anterior segment tissues following injection of capsid-mutated AAV vectors. scAAV2- based vectors transduced corneal endothelium, ciliary NPE, iris and trabecular meshwork more effectively than scAAV8-based vectors. Mutagenesis of surface-exposed tyrosine residues greatly enhanced transduction efficiency of scAAV2 in these tissues. The number of Y-F mutations was not directly proportional to transduction efficiency, however, suggesting that proteosomal avoidance alone may not be sufficient. These results are applicable to the development of targeted, gene-based strategies to investigate pathological processes of the anterior segment and may be applied toward the development of gene

  9. Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle.

    Science.gov (United States)

    Sakata, Lisandro M; Lavanya, Raghavan; Friedman, David S; Aung, Han T; Gao, Hong; Kumar, Rajesh S; Foster, Paul J; Aung, Tin

    2008-05-01

    To compare the performance of gonioscopy and anterior segment (AS) optical coherence tomography (OCT) in detecting angle closure in the different quadrants of the anterior chamber angle (ACA). Cross-sectional observational study. Five hundred two consecutive subjects more than 50 years of age with no previous ophthalmic problems recruited from a community clinic in Singapore. All subjects underwent gonioscopy and AS OCT imaging in the dark. Using gonioscopy, the ACA was graded using the Scheie system by a single examiner masked to AS OCT findings. The ACA in a particular quadrant was classified as closed if the posterior trabecular meshwork could not be seen on gonioscopy. A closed ACA on AS OCT imaging was defined by the presence of any contact between the iris and angle wall anterior to the scleral spur. After excluding eyes with poor image quality, a total of 423 right eyes were included in the analysis. A closed angle in at least 1 quadrant was observed in 59% of the eyes by AS OCT and in 33% of the eyes by gonioscopy (Pgonioscopy were 48% versus 29% superiorly, 43% versus 22% inferiorly, 18% versus 14% nasally, and 12% versus 20% temporally, respectively. Of the 119 of 1692 quadrants that were closed on gonioscopy but open on AS OCT, a steep iris profile was present in 61 (51%) of 119 quadrants on AS OCT, and of the 276 of 1692 quadrants that were open on gonioscopy but closed on AS OCT, 196 (71%) of 276 quadrants showed short iridoangle contact on AS OCT. The highest rates of closed angles on gonioscopy and AS OCT images were observed in the superior quadrant. Anterior segment OCT tended to detect more closed ACAs than gonioscopy, particularly in the superior and inferior quadrants. Variations in the iris profile and level of iridoangle contact also may explain some of the differences seen between gonioscopy and AS OCT.

  10. Effect of paracentesis on metabolic activity in patients with advanced cirrhosis and ascites

    DEFF Research Database (Denmark)

    Knudsen, Anne Wilkens; Krag, Aleksander; Nordgaard-Lassen, Inge

    2016-01-01

    Objective Patients with decompensated cirrhosis often suffer from malnutrition. To enable appropriate nutritional supplementation a correct estimation of resting energy expenditure (REE) is needed. It is, however, unclear whether the volume of ascites should be included or not in the calculations...... by -379 (-1915 - 219) kJ/day, (p  = 0.06). Patients in whom measured REE decreased after paracentesis had higher middle arterial pressure (MAP) (p = 0.02) and p-sodium (p = 0.02) at baseline. Low HGS (M: osteoporosis...

  11. Preservation of nutritional-status in patients with refractory ascites due to hepatic cirrhosis who are undergoing repeated paracentesis.

    Science.gov (United States)

    Sorrentino, Paolo; Castaldo, Giuseppe; Tarantino, Luciano; Bracigliano, Alessandra; Perrella, Alessandro; Perrella, Oreste; Fiorentino, Francesco; Vecchione, Raffaela; D' Angelo, Salvatore

    2012-04-01

    Refractory ascites in liver-cirrhosis is associated with a poor prognosis. We performed a prospective study to investigate whether aggressive nutritional-support could improve outcomes in cirrhotic patients. Cirrhotic patients undergoing serial large-volume paracentesis for refractory-ascites were enrolled and randomized into three groups. Group A received post-paracentesis intravenous nutritional-support in addition to a balanced oral diet and a late-evening protein snack, group B received the same oral nutritional-protocol as the first group but without parenteral support, and group C (the control group) received a low-sodium or sodium-free diet. Clinical, anthropometric and laboratory nutritional parameters and biochemical tests of liver and renal function were reported for 12 months of follow-up. We enrolled 120 patients, who were randomized into three groups of equal size. Patients on the nutritional-protocol showed better preservation of clinical, anthropometric and laboratory nutritional parameters that were associated with decreased deterioration of liver function compared with patients on the low-sodium or sodium-free diet (group C). Groups A and B had lower morbidity and mortality rates than the control group (C). Mortality rates were significantly better in patients who were treated with parenteral-nutritional-support than for the other two groups. In patients who were on the nutritional-protocol, there was a reduction in the requirement of taps for the treatment of refractory ascites. Post-paracentesis parenteral-nutritional-support with a balanced oral diet and an evening protein snack appears to be the best care protocol for patients with liver-cirrhosis that has been complicated by refractory-ascites. © 2011 Journal of Gastroenterology and Hepatology Foundation and Blackwell Publishing Asia Pty Ltd.

  12. Reduced Albumin Dosing During Large-Volume Paracentesis Is Not Associated with Adverse Clinical Outcomes.

    Science.gov (United States)

    Johnson, Kara B; Mueller, Jessica L; Simon, Tracey G; Zheng, Hui; King, Lindsay Y; Makar, Robert S; Gervais, Debra A; Chung, Raymond T

    2015-07-01

    LVP is used to manage diuretic-resistant ascites in cirrhotic patients. Albumin administration prevents complications including acute kidney injury and paracentesis-induced circulatory dysfunction, but the optimal dose is unclear. We sought to assess adherence to guidelines enacted in July 2011 at our center for reducing the albumin dose administered at large-volume paracentesis (LVP) and evaluate the cost and rate of complications of LVPs before and after guideline enactment. All LVPs performed on cirrhotic patients in our center's Department of Radiology between July 2009 and January 2014 were studied. Outcomes included adherence to guidelines, LVP complications, and administered albumin cost. Groups were compared using Student's t tests for continuous data and Chi-square or Fisher's exact tests for categorical data. A repeated measurements model accounted for patients with multiple LVPs. Of the 935 LVPs, 288 occurred before guideline implementation (group 1) and 647 occurred after (group 2). The mean dose of albumin administered was 13.7 g/L of ascites removed in group 1 versus 10.3 g/L in group 2 (p albumin administration and associated cost savings was still observed. There was no increase in LVP-related complications after guideline implementation or in the adherent group, suggesting that albumin dose can be safely reduced. Future efforts should be directed at enhancing guideline adherence and potentially further reducing albumin dosing.

  13. Distribution of radioactively labelled myobacterium tuberculosis (65Zn, 35S-BCG) after injection into the anterior chamber. Studies in rabbits with and without anterior chamber sensitisation

    International Nuclear Information System (INIS)

    Tabillion, M.

    1985-01-01

    The rabbit model was used to study the behaviour of antigens in the eye as well as their spread to extraocular regions. Prior to the investigations, a test dose of 35 S-labelled and 65 Zn-labelled BCG (Bacille Calmette Guerin) had been injected into the anterior chamber of the eyes of sensitised and non-sensitised rabbits. The percentage of BCG escaping from the aqueous humor and iris was mostly not dependent of the test dose given, nor did the rate of its spread show any relation to the occurrence of an antigen-antibody reaction. On the 32nd day p.i., there were still acid-resisting rods in the uvea, which could be proven by histological examination. As shown by the levels of activity in the iris and ciliary body, the bacteria appear to migrate mostly to these organs and, in the second place, to the choroid membrane. The spread of bacteria in previously sensitised rabbits was not different from the observed in non-sensitised animals. Theories claiming that more antigens are formed in sensitised tissue as compared to non-sensitised tissue cannot be confirmed by the findings revealed here. (TRV) [de

  14. Autoradiographic demonstration of glucocorticoid receptors in the intermediate lobe of the rat pituitary transplanted to the anterior eye chamber

    International Nuclear Information System (INIS)

    Ruehle, H.J.; Schnabel, C.; Lausch, A.

    1989-01-01

    The neurointermediate lobe of adult male Wistar rats was syngeneic transplanted to the anterior eye chamber. The recipient rats were adrenalectomized 19 days after grafting and injected with (3H)corticosterone 5 days later. After a survival time of 60 min, autoradiograms were prepared by thaw-mount technique and quantitatively evaluated by silver grain counting. Beside the classical targets, anterior pituitary and hippocampal stratum pyramidale, the intraocular transplants showed a nuclear accumulation of radioactivity. This was abolished in rats treated for competition with an excess of unlabelled corticosterone prior to tracer application. No such receptor binding was found in the normotopic intermediate lobe and in the diaphragm studied as a non-target reference. Thus, this study confirmed that the glucocorticoid receptor gene is expressed of the tissue is grafted into an ectopic site. (author)

  15. Effect of altered eating habits and periods during Ramadan fasting on intraocular pressure, tear secretion, corneal and anterior chamber parameters.

    Science.gov (United States)

    Kerimoglu, H; Ozturk, B; Gunduz, K; Bozkurt, B; Kamis, U; Okka, M

    2010-01-01

    To determine whether altered eating habits and periods, especially the pre-dawn meal, during Ramadan fasting have any significant effect on intraocular pressure (IOP), tear secretion, corneal and anterior chamber parameters. IOP, basal tear secretion (BTS), reflex tear secretion (RTS), and Pentacam measurements of 31 healthy volunteers were performed at 0800 and 1600 hours during Ramadan fasting and 1 month later during non-fasting period. Comparison of measurements between fasting and non-fasting periods at 0800 hours revealed significantly higher values for IOP (P=0.005), RTS (P=0.006), and BTS (P=0.014) during fasting. Conversely at 1600 hours, IOP was significantly lower during fasting (P=0.013) and no statistically significant difference was noted for RTS and BTS. IOP showed a diurnal variation of 2.45 mmHg (P<0.001) and BTS showed a 3.06 mm decrease (P=0.04) during the fasting period. No significant differences could be found in the corneal and anterior chamber parameters during fasting and non-fasting periods. Our results revealed that fluid loading at the pre-dawn meal during Ramadan fasting might increase the IOP and tear secretion in the early morning period and these values decrease remarkably at the end of 12 h of fasting due to dehydration.

  16. [Opacification of an intraocular lens: calcification of hydrophilic intraocular lenses after gas tamponade of the anterior chamber].

    Science.gov (United States)

    Schmidinger, G; Pemp, B; Werner, L

    2013-11-01

    A patient with endothelial dystrophy was treated with Descemet stripping automated endothelial keratoplasty (DSAEK) combined with cataract extraction and implantation of a hydrophilic intraocular lens (IOL, Lentis-L312, Oculentis) but visual acuity dropped from 0.15 logMAR to 0.52 logMAR 18 months later due to calcification of the IOL. With new methods of lamellar corneal transplantation being used more frequently the number of necessary anterior chamber tamponades with air/gas are increasing. In cataract cases in which a gas tamponade and transplantation might be necessary later on (cornea guttata), hydrophilic IOLs should be avoided.

  17. Management of hypotony and flat anterior chamber associated with glaucoma filtration surgery

    Directory of Open Access Journals (Sweden)

    Yavuz Tunç

    2015-10-01

    Full Text Available AIM:To determine the effectiveness of pharmacological and interventional treatment of hypotony and flat anterior chamber (FAC resulting from glaucoma filtration surgery.METHODS:We retrospectively examined the medical records of fifty-two trabeculectomy patients (52 eyes who developed postoperative hypotony and FAC. The management and associated complications of hypotony, changing intraocular pressure (IOP and best corrected visual acuity (BCVA were evaluated.RESULT:Of the 52 patients with hypotony, 29 (56% had a grade 1 FAC, 21 (40% had a grade 2 FAC, and only 2 had a grade 3 FAC. There was no significant difference between the mean preoperative IOP and the mean IOP at three and six months after surgery. Thirteen eyes (25% required antiglaucomatous medication three months after surgery. The mean BCVA at 6mo after surgery was significantly reduced as compared with the mean preoperative BCVA.CONCLUSION:Hypotonia and FAC following trabeculectomy are associated with troublesome complications that require pharmacological and/or surgical treatment. Thus, close follow-up is essential for affected patients.

  18. Use of EyeCam for imaging the anterior chamber angle.

    Science.gov (United States)

    Perera, Shamira A; Baskaran, Mani; Friedman, David S; Tun, Tin A; Htoon, Hla M; Kumar, Rajesh S; Aung, Tin

    2010-06-01

    To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) imaging with gonioscopy for detecting angle closure. In this prospective, hospital-based study, subjects underwent gonioscopy by a single observer and EyeCam imaging by a different operator. EyeCam images were graded by two masked observers. The anterior chamber angle in a quadrant was classified as closed if the trabecular meshwork could not be seen. The eye was classified as having angle closure if two or more quadrants were closed. One hundred fifty-two subjects were studied. The mean age was 57.4 years (SD 12.9) and there were 82 (54%) men. Of the 152 eyes, 21 (13.8%) had angle closure. The EyeCam provided clear images of the angles in 98.8% of subjects. The agreement between the EyeCam and gonioscopy for detecting angle closure in the superior, inferior, nasal, and temporal quadrants based on agreement coefficient (AC1) statistics was 0.73, 0.75, 0.76, and 0.72, respectively. EyeCam detected more closed angles than did gonioscopy in all quadrants (P gonioscopy, 21/152 (13.8%) eyes were diagnosed as angle closure compared to 41 (27.0%) of 152 with EyeCam (P gonioscopy for detecting angle closure. However, it detected more closed angles than did gonioscopy in all quadrants.

  19. Evaluation of anterior chamber angle under dark and light conditions in angle closure glaucoma: An anterior segment OCT study.

    Science.gov (United States)

    Masoodi, Habibeh; Jafarzadehpur, Ebrahim; Esmaeili, Alireza; Abolbashari, Fereshteh; Ahmadi Hosseini, Seyed Mahdi

    2014-08-01

    To evaluate changes of nasal and temporal anterior chamber angle (ACA) in subjects with angle closure glaucoma using Spectralis AS-OCT (SAS-OCT) under dark and light conditions. Based on dark-room gonioscopy, 24 subjects with open angles and 86 with narrow angles participated in this study. The nasal and temporal angle opening distance at 500 μm anterior to the scleral spur (AOD500), nasal and temporal ACA were measured using SAS-OCT in light and dark conditions. In 2 groups, ACA and AOD500 in nasal and temporal quadrants were significantly greater in light compared to dark (all with p=0.000). The AOD500 and ACA were significantly higher in nasal than temporal in measured conditions for 2 groups except the ACA and AOD500 of normal group measured in light. The difference between nasal and temporal in dark (29.07 ± 65.71 μm for AOD500 and 5.7 ± 4.07° for ACA) was greater than light (24.86 ± 79.85 μm for AOD500 and 2.09 ± 7.21° for ACA) condition. But the difference was only significant for ACA (p=0.000). The correlation analysis showed a negative correlation between AOD500 and pupil diameter in temporal and nasal quadrants (both with p=0.000). While temporal AOD500 difference correlated with spherical equivalent, temporal and asal gonioscopy, nasal AOD correlated with IOP, temporal and nasal gonioscopy. Clinically important changes in ACA structure could be detected with SAS-OCT in nasal and temporal quadrants under different illumination intensity. The results could help in improvement of examination condition for better and more accurate assessment of individuals with angle closure glaucoma. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  20. Combined pars plana lensectomy-vitrectomy with open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for subluxated lenses.

    Science.gov (United States)

    Kazemi, S; Wirostko, W J; Sinha, S; Mieler, W F; Koenig, S B; Sheth, B P

    2000-01-01

    To review our experience with combined pars plana lensectomy-vitrectomy and open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for managing subluxated crystalline lenses. Retrospective review of 36 consecutive eyes (28 patients), all of which had subluxated crystalline lenses, managed by pars plana lensectomy-vitrectomy with insertion of an open-loop flexible AC IOL. The study was performed at the Medical College of Wisconsin, Milwaukee, over an 8-year period. An average preoperative visual acuity of 20/163 (range, 20/25 to hand motions) improved to 20/36 (range, 20/20 to 4/200) with surgery after a mean follow-up of 14 months (range, 1 to 59 months) (P IOL implantation appears to be an excellent technique for managing subluxated crystalline lenses. It is associated with a significant improvement in visual acuity (P subluxated lens through a limbal wound. Additionally, use of an AC IOL offers a simplified alternative to placement of a ciliary sulcus sutured posterior chamber intraocular lens (PC IOL).

  1. Anterior migration of dexamethasone implant in a pseudophakic patient with intact posterior capsule

    Directory of Open Access Journals (Sweden)

    Nilufer Kocak

    2014-01-01

    Full Text Available Intravitreal application of Ozurdex ® (Allergan, Inc., Irvine, CA, USA which is a biodegradable, sustained-release dexamethasone implant has been reported to be effective in the treatment of macular edema. Migration of such implant into the anterior chamber has been recently described in cases without perfect zonular or the posterior capsular integrity. Herein, we report the first case with anterior migration of Ozurdex ® implant that mislocated just behind the intraocular lens (IOL in an intact capsular bag. It is thought that such implant migrated anteriorly towards into the posterior chamber through weak zonules as the present case had a medical history of uneventful phacoemulsification surgery with the implantation of posterior chamber IOL. However, the migrated implant was well tolerated since there was no sign of the corneal complication, rise in intraocular pressure, and anterior chamber reaction. Close follow-up was scheduled to find out any signs of anterior segment pathology. Meanwhile dexamethasone implant completely degraded at the 4 th month of postoperative follow-up.

  2. Refraction and eye anterior segment parameters in schizophrenic patients

    Directory of Open Access Journals (Sweden)

    Tongabay Cumurcu

    2015-06-01

    Full Text Available ABSTRACT Purpose: To evaluate the difference in terms of refractive errors and anterior segment parameters between schizophrenic patients and healthy volunteers. Methods: This study compared 70 patients (48 men who were diagnosed with schizophrenia with a control group of 60 (35 men who were similar in terms of age, gender, education, and socioeconomic level. Anterior segment examination was performed using a Scheimflug system. Axial length and lens thickness (LT were measured using optic biometry. The following tests were administered to the psychiatric patient group: Brief Psychiatric Rating Scale (BPRS, Scale for the Assessment of Negative Symptoms (SANS, and Scale for the Assessment of Positive Symptoms (SAPS. Results: Mild myopia was detected in both the schizophrenic and control groups, with no statistically significant difference (p>0.005. Corneal volume (CV, anterior chamber volume (ACV, anterior chamber depth (ACD, and central corneal thickness (CCT values were lower in the schizophrenic group, and there was a statistically significant between-group difference (p=0.026, p=0.014, p=0.048, and p=0.005, respectively. LT was greater in schizophrenics, and the difference was found to be statistically significant (p=0.006. A statistically significant negative correlation was found between SAPS and cylinder values (p=0.008. The axial eye length, cylinder value, pupil diameter, mean keratometric value, and anterior chamber angle revealed no statistically significant difference between the groups (p>0.05. Conclusion: No statistically significant difference was detected in terms of refraction disorders between schizophrenics and the healthy control group, while some differences in anterior chamber parameters were present. These results demonstrate that schizophrenics may exhibit clinical and structural differences in the eye.

  3. Comparative evaluation of aqueous humor viscosity.

    Science.gov (United States)

    Davis, Kyshia; Carter, Renee; Tully, Thomas; Negulescu, Ioan; Storey, Eric

    2015-01-01

    To evaluate aqueous humor viscosity in the raptor, dog, cat, and horse, with a primary focus on the barred owl (Strix varia). Twenty-six raptors, ten dogs, three cats, and one horse. Animals were euthanized for reasons unrelated to this study. Immediately, after horizontal and vertical corneal dimensions were measured, and anterior chamber paracentesis was performed to quantify anterior chamber volume and obtain aqueous humor samples for viscosity analysis. Dynamic aqueous humor viscosity was measured using a dynamic shear rheometer (AR 1000 TA Instruments, New Castle, DE, USA) at 20 °C. Statistical analysis included descriptive statistics, unpaired t-tests, and Tukey's test to evaluate the mean ± standard deviation for corneal diameter, anterior chamber volume, and aqueous humor viscosity amongst groups and calculation of Spearman's coefficient for correlation analyses. The mean aqueous humor viscosity in the barred owl was 14.1 centipoise (cP) ± 9, cat 4.4 cP ± 0.2, and dog 2.9 cP ± 1.3. The aqueous humor viscosity for the horse was 1 cP. Of the animals evaluated in this study, the raptor aqueous humor was the most viscous. The aqueous humor of the barred owl is significantly more viscous than the dog (P humor viscosity of the raptor, dog, cat, and horse can be successfully determined using a dynamic shear rheometer. © 2014 American College of Veterinary Ophthalmologists.

  4. The Effects of Ramadan Fasting on Anterior Segment Parameters, Visual Acuity and Intraocular Pressures of the Eye.

    Science.gov (United States)

    Selver, Ozlem Barut; Palamar, Melis; Gerceker, Kevser; Egrilmez, Sait; Yagci, Ayse

    2017-01-01

    It is aimed to determine whether fasting during Ramadan has any significant effect on anterior chamber parameters, visual acuity and intraocular pressures. 31 fasting (Group 1) and 30 non-fasting healthy volunteers (Group 2) were enrolled. All cases underwent an ophthalmological examination and anterior segment parameter evaluation (central corneal thickness (CCT), anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), pupil size) with Pentacam before and after the breaking of the Ramadan fast in Group 1, before and after dinner in Group 2. The mean age was 43.35 ± 13.20 in Group 1, 43.17 ± 12.90 in Group 2 (p= 0.955). No significant difference was detected in any of the parameters in both groups. There is a need for more detailed and associated studies to understand better about the influence of Ramadan fast on various ocular parameters.

  5. Anterior dislocation of an empty capsular bag in a pseudophakic eye: A rare case report

    Directory of Open Access Journals (Sweden)

    Hyung Bin Hwang

    2015-01-01

    Full Text Available Spontaneous intraocular lens (IOL dislocation is uncommon in the absence of any ocular areas with zonular weakness or trauma. There have been no reports of spontaneous capsular bag dislocation into the anterior chamber without an IOL. We report a rare, interesting case of spontaneous capsular bag anterior dislocation, without an IOL, into the anterior chamber with no history of genetic disease, ocular trauma, or pseudoexfoliation that might predispose to a zonular abnormality.

  6. A case involving an Ahmed™ glaucoma valve transferred from the vitreous into the anterior chamber of the eye with a silicone oil tamponade for the treatment of neovascular glaucoma

    Directory of Open Access Journals (Sweden)

    Miki M

    2013-02-01

    Full Text Available Michiko Miki, Mari Ueki, Tetsuya Sugiyama, Shota Kojima, Tsunehiko IkedaDepartment of Ophthalmology, Osaka Medical College, Takatsuki, JapanPurpose: To report the short-term efficacy and safety of the transfer of an Ahmed™ glaucoma valve (AGV™ tube from the vitreous into the anterior chamber, in a patient with neovascular glaucoma who had undergone pars plana AGV™ implantation and ultimately needed a silicone oil tamponade.Case: A 41-year-old male with proliferative diabetic retinopathy in both eyes was referred to us for treatment in December 2009. Although the patient previously underwent several surgeries, he ultimately lost vision in his right eye. His left eye suffered from neovascular glaucoma after undergoing a pars plana vitrectomy for tractional retinal detachment. After several vitreous and glaucoma surgeries, the patient underwent implantation of a pars plana AGV™. Postoperatively, although his intraocular pressure was stabilized at approximately 10 mmHg, he had repeated vitreous hemorrhage and hyphema without improvement. He ultimately underwent PPV with a silicone oil tamponade and at the same time, the AGV™ tube was pulled out from the vitreous and inserted into the anterior chamber in order to avoid complications caused by the silicone oil.Results: At 19 months postoperative, the patient’s intraocular pressure had stabilized at 10 mmHg with no recurrence of vitreous hemorrhage and hyphema. Eventually, he lost vision in his left eye because of cerebral hemorrhage.Conclusion: The findings show that insertion of a pars plana AGV™ tube into the anterior chamber in a patient undergoing a silicone oil tamponade is both effective and safe in the short-term.Keyword: tube implantation, glaucoma surgery, tube transfer, pars plana, proliferative diabetic retinopathy, intraocular pressure

  7. Novel spatula and dissector for safer deep anterior lamellar keratoplasty

    Directory of Open Access Journals (Sweden)

    Gustavo ,2,3 Bonfadini

    2014-10-01

    Full Text Available Objective: We describe a novel spatula and dissector to facilitate the big-bubble technique in deep anterior lamellar keratoplasty (DALK. Methods: A 29-year-old man who was diagnosed with bilateral keratoconus underwent deep anterior lamellar keratoplasty (DALK. After 350μm partial thickness incision of the recipient cornea, the Bonfadini dissector was inserted at the deepest point in the peripheral incision and could be advanced to the center of the cornea safely because of its "semi-sharp" tip. After achieving the big-bubble (BB separation of Descemet membrane (DM from the overlying stroma, the anterior stromal disc was removed. Viscoelastic material was placed on the stromal bed to prevent uncontrolled collapse and perforation of DM during the paracentesis blade incision into the BB. We could detect the safe opening of the BB using the Bonfadini dissector by the leakage of air bubbles into the viscoelastic material. After injecting viscoelastic material into the BB space, we inserted the Bonfadini spatula into the bigbubble safely because of its curved profile and blunt edges. The groove along the length of the Bonfadini spatula enables safe and efficient incision or the residual stromal tissue using the pointed end of a sharp blade while protecting the underlying DM. After removal of posterior stroma, the donor button was sutured with 16 interrupted 10-0 nylon sutures. Results: This technique and the use of the Bonfadini spatula and dissector facilitate exposure of Descemet membrane. Conclusion: The smooth Bonfadini DALK spatula and dissector facilitate safe and efficient completion of DALK surgery.

  8. Optical coherence tomography in anterior segment imaging

    Science.gov (United States)

    Kalev-Landoy, Maya; Day, Alexander C.; Cordeiro, M. Francesca; Migdal, Clive

    2008-01-01

    Purpose To evaluate the ability of optical coherence tomography (OCT), designed primarily to image the posterior segment, to visualize the anterior chamber angle (ACA) in patients with different angle configurations. Methods In a prospective observational study, the anterior segments of 26 eyes of 26 patients were imaged using the Zeiss Stratus OCT, model 3000. Imaging of the anterior segment was achieved by adjusting the focusing control on the Stratus OCT. A total of 16 patients had abnormal angle configurations including narrow or closed angles and plateau irides, and 10 had normal angle configurations as determined by prior full ophthalmic examination, including slit-lamp biomicroscopy and gonioscopy. Results In all cases, OCT provided high-resolution information regarding iris configuration. The ACA itself was clearly visualized in patients with narrow or closed angles, but not in patients with open angles. Conclusions Stratus OCT offers a non-contact, convenient and rapid method of assessing the configuration of the anterior chamber. Despite its limitations, it may be of help during the routine clinical assessment and treatment of patients with glaucoma, particularly when gonioscopy is not possible or difficult to interpret. PMID:17355288

  9. Automated analysis of angle closure from anterior chamber angle images.

    Science.gov (United States)

    Baskaran, Mani; Cheng, Jun; Perera, Shamira A; Tun, Tin A; Liu, Jiang; Aung, Tin

    2014-10-21

    To evaluate a novel software capable of automatically grading angle closure on EyeCam angle images in comparison with manual grading of images, with gonioscopy as the reference standard. In this hospital-based, prospective study, subjects underwent gonioscopy by a single observer, and EyeCam imaging by a different operator. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. An eye was classified as having angle closure if there were two or more quadrants of closure. Automated grading of the angle images was performed using customized software. Agreement between the methods was ascertained by κ statistic and comparison of area under receiver operating characteristic curves (AUC). One hundred forty subjects (140 eyes) were included, most of whom were Chinese (102/140, 72.9%) and women (72/140, 51.5%). Angle closure was detected in 61 eyes (43.6%) with gonioscopy in comparison with 59 eyes (42.1%, P = 0.73) using manual grading, and 67 eyes (47.9%, P = 0.24) with automated grading of EyeCam images. The agreement for angle closure diagnosis between gonioscopy and both manual (κ = 0.88; 95% confidence interval [CI), 0.81-0.96) and automated grading of EyeCam images was good (κ = 0.74; 95% CI, 0.63-0.85). The AUC for detecting eyes with gonioscopic angle closure was comparable for manual and automated grading (AUC 0.974 vs. 0.954, P = 0.31) of EyeCam images. Customized software for automated grading of EyeCam angle images was found to have good agreement with gonioscopy. Human observation of the EyeCam images may still be needed to avoid gross misclassification, especially in eyes with extensive angle closure. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  10. Anterior chamber gas bubble emergence pattern during femtosecond LASIK-flap creation.

    Science.gov (United States)

    Robert, Marie-Claude; Khreim, Nour; Todani, Amit; Melki, Samir A

    2015-09-01

    To characterise the emergence pattern of cavitation bubbles into the anterior chamber (AC) following femtosecond laser-assisted in situ keratomileusis (LASIK)-flap creation Retrospective review of patients undergoing femtosecond LASIK surgery at Boston Laser, a private refractive surgery practice in Boston, Massachusetts, between December 2008 and February 2014. Patient charts were reviewed to identify all cases with gas bubble migration into the AC. Surgical videos were examined and the location of bubble entry was recorded separately for right and left eyes. Five thousand one hundred and fifty-eight patients underwent femtosecond LASIK surgery. Air bubble migration into the AC, presumably via the Schlemm's canal and trabecular meshwork, occurred in 1% of cases. Patients with AC bubbles had an average age of 33±8 years with a measured LASIK flap thickness of 96±21 μm. The occurrence of gas bubbles impaired iris registration in 64% of cases. Gas bubbles appeared preferentially in the nasal or inferior quadrants for right (92% of cases) and left (100% of cases) eyes. This bubble emergence pattern is significantly different from that expected with a random distribution (p<0.0001) and did not seem associated with decentration of the femtosecond laser docking system. The migration of gas bubbles into the AC is a rare occurrence during femtosecond laser flap creation. The preferential emergence of gas bubbles into the nasal and inferior quadrants of the AC may indicate a distinctive anatomy of the nasal Schlemm's canal. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Comparison between a New Optical Biometry Device and an Anterior Segment Optical Coherence Tomographer for Measuring Central Corneal Thickness and Anterior Chamber Depth

    Directory of Open Access Journals (Sweden)

    Jinhai Huang

    2016-01-01

    Full Text Available Purpose. To compare between a new optical biometer (AL-Scan, Nidek Co., Aichi, Japan and an anterior segment optical coherence tomographer (Visante AS-OCT, Carl Zeiss Meditec, Dublin, USA for measuring central corneal thickness (CCT, anterior chamber depth (ACD, and aqueous depth (AD. Methods. Sixty-three eyes of 63 normal subjects were examined with AL-Scan and Visante AS-OCT in this prospective study. One eye per subject was measured three times with both devices to record their CCT, ACD, and AD. All procedures were performed by the same operator. Agreement between the two devices was assessed using paired t-tests, Bland-Altman plots, and 95% limits of agreement (LoA. Results. The mean CCT, ACD, and AD measured by AL-Scan were 538.59±27.37 μm, 3.70±0.30 mm, and 3.16±0.30 mm, respectively. The mean values obtained by the Visante OCT were 536.14±26.61 μm for CCT, 3.71±0.29 mm for ACD, and 3.17±0.29 mm for AD. The mean CCT by the AL-Scan was higher than that obtained by the Visante AS-OCT (difference = 2.45±6.07 μm, P<0.05. The differences in ACD and AD measurements were not statistically significant. The 95% LoA of CCT, ACD, and AD were between −9.44 and 14.35 μm, −0.15 and 0.12 mm, and −0.15 and 0.12 mm, respectively. Conclusions. Since these two devices were comparable for measuring CCT, ACD, and AD, their results can be interchangeably used in the clinic.

  12. Distribution of axial length, anterior chamber depth, and corneal curvature in an aged population in South China.

    Science.gov (United States)

    Chen, Hui; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Chen, Weirong

    2016-05-01

    Ocular biometry is important for preoperative assessment in cataract and anterior segment surgery. The purpose of this study was to investigate normative ocular biometric parameters and their associations in an older Chinese population. This was a cross-sectional observational study. From 2013 to 2014, we recruited inhabitants aged 50 years or older in Guangzhou, China. Among 1,117 participants in the study, data from 1,015 phakic right eyes were used for analyses. Ocular parameters including axial length (AL), anterior chamber depth (ACD), and corneal curvature (K) were measured using an IOL Master. The mean AL, ACD, and K were 23.48 mm [95 % confidence interval (CI), 23.40-23.55], 3.03 mm (CI, 3.01-3.05), and 44.20 mm (CI, 44.11-44.29), respectively. A mean reduction in ACD with age was observed (P = 0.002) in male subjects but not in female subjects (P = 0.558). Male subjects had significantly longer ALs (23.68 mm versus 23.23 mm, P population in South China. The AL in this Chinese cohort was greater than that observed in the Singaporean Chinese but smaller than that observed in Malaysia and for Caucasians. The Chinese have a shallower ACD than some other racial groups. Age and sex were the most consistent predictors of ocular biometry in the older population from South China.

  13. Anterior Segment Ischemia after Strabismus Surger

    Directory of Open Access Journals (Sweden)

    Emine Seyhan Göçmen

    2017-01-01

    Full Text Available A 46-year-old male patient was referred to our clinic with complaints of diplopia and esotropia in his right eye that developed after a car accident. The patient had right esotropia in primary position and abduction of the right eye was totally limited. Primary deviation was over 40 prism diopters at near and distance. The patient was diagnosed with sixth nerve palsy and 18 months after trauma, he underwent right medial rectus muscle recession. Ten months after the first operation, full-thickness tendon transposition of the superior and inferior rectus muscles (with Foster suture was performed. On the first postoperative day, slit-lamp examination revealed corneal edema, 3+ cells in the anterior chamber and an irregular pupil. According to these findings, the diagnosis was anterior segment ischemia. Treatment with 0.1/5 mL topical dexamethasone drops (16 times/day, cyclopentolate hydrochloride drops (3 times/day and 20 mg oral fluocortolone (3 times/day was initiated. After 1 week of treatment, corneal edema regressed and the anterior chamber was clean. Topical and systemic steroid treatment was gradually discontinued. At postoperative 1 month, the patient was orthophoric and there were no pathologic symptoms besides the irregular pupil. Anterior segment ischemia is one of the most serious complications of strabismus surgery. Despite the fact that in most cases the only remaining sequel is an irregular pupil, serious circulation deficits could lead to phthisis bulbi. Clinical properties of anterior segment ischemia should be well recognized and in especially risky cases, preventative measures should be taken.

  14. Complications and Management of Deep Anterior Lamellar Keratoplasty

    Directory of Open Access Journals (Sweden)

    Banu Torun Acar

    2014-10-01

    Full Text Available Objectives: To report the intraoperative and postoperative follow-up complications and management of these in deep anterior lamellar keratoplasty (DALK surgery. Materials and Methods: Two hundred eighty-four eyes of 252 patients followed up in our cornea clinic who underwent DALK using Anwar’s big-bubble technique with healthy Descemet’s membrane and endothelium were included in this study. Intraoperative and postoperative complications as well as the management and treatment of these complications were evaluated. Results: Big bubble was created in 220 (77.5% eyes of 284 eyes, and lamellar dissection was performed in 64 (22.5% eyes. Perforation occurred during trephination in 4 eyes, and the procedure was accomplished by penetrating keratoplasty (PK. Intraoperative microperforation occurred in 44 eyes. Perforation enlarged in 4 eyes and PK was performed. Operation was continued in 40 eyes with air injection into the anterior chamber. In postopertive follow-up period, double anterior chamber (DAC occurred in 32 of 40 eyes. DAC spontaneously regressed in 8 eyes, and air was given into the anterior chamber with a second surgical intervention in 24 eyes. DAC improved in 20 eyes. Four eyes underwent PK. Fungal keratitis evolved at the interface in one eye, because of no healing during the follow-up period, this eye underwent PK under antifungal therapy. Eyes with interface haze and Descemet’s membrane folds were followed. Conclusion: DALK is a difficult technique with a steep learning curve. In addition to the complications seen in PK, specific complications can occur in lamellar surgery. (Turk J Ophthalmol 2014; 44: 337-40

  15. Fibrinous anterior uveitis following laser in situ keratomileusis

    Directory of Open Access Journals (Sweden)

    Parmar Pragya

    2009-01-01

    Full Text Available A 29-year-old woman who underwent laser in situ keratomileusis (LASIK for myopic astigmatism in both eyes presented with severe pain, photophobia and decreased visual acuity in the left eye eight days after surgery. Examination revealed severe anterior uveitis with fibrinous exudates in the anterior chamber, flap edema and epithelial bullae. Laboratory investigations for uveitis were negative and the patient required systemic and intensive topical steroids with cycloplegics to control the inflammation. This case demonstrates that severe anterior uveitis may develop after LASIK and needs prompt and vigorous management for resolution.

  16. Multiple Coronary Chamber Microfistulas or Persistent Thebesian Vessels?

    Directory of Open Access Journals (Sweden)

    Cernica Daniel

    2017-09-01

    Full Text Available Coronary fistulas are rare, not gender-specific congenital conditions, consisting of communications between the coronary arteries and either another coronary vessel or a cardiac chamber. In contrast to large fistulas, small fistulas, named “minimae cordis veneae” or the Thebesius venous system, are draining into heart chambers and form a vascular network in the cardiac lumen. In this article, we present the case of a 72-year-old female with a significant history of cardiovascular disease, admitted to our clinic because of rest dyspnea, fatigue, and minimal chest pain. The 12-lead electrocardiogram showed a trifascicular block (a second-degree atrioventricular block Mobitz II, associated with a right bundle branch block and left anterior fascicle block and negative T waves in DII, DIII, aVF, V4–V6 leads. An invasive coronary angiography was performed, which revealed no significant atherosclerotic lesions. However, a persistent capillary blush was present at the apex site of the left ventricular chamber, draining from the distal segments of both the anterior descending coronary artery and the posterior interventricular coronary artery. The intramural vascular network generating a left ventricle angiogram image of this kind was suggestive for persistent Thebesian vessels connecting the two coronaries with the left ventricular chamber.

  17. Sildenafil Stimulates Aqueous Humor Turnover in Rabbits

    Science.gov (United States)

    Alvarez, Lawrence J.; Zamudio, Aldo C.; Candia, Oscar A.

    2013-01-01

    Sildenafil citrate increases ocular blood flow and accelerates the rate of anterior chamber refilling after paracentesis. The latter effect could have resulted from a reduction in outflow facility or from an increase in aqueous humor (AH) production. In this study, we used scanning ocular fluorophotometry to examine the effects of sildenafil on AH turnover, and thus, AH production in eyes of live normal rabbits. For this, the rate of aqueous humor flow (AHF) was quantified with a commercially available fluorophotometer that measured the rate of fluorescein clearance from the anterior segment, which predominantly occurs via the trabecular meshwork. After ≈ 2 hrs of control scans to determine the baseline rate of AHF, the rabbits were fed 33 mg of sildenafil and allowed ≈ 45 min for the drug to enter the systemic circulation. Thereafter, fluorescence scans were retaken for an additional 90–120 min. Sildenafil ingestion increased AHF by about 36%, from 2.31 μL/min to 3.14 μL/min (PViagra, Revatio), stimulates AHF in rabbits. Our results seem consistent with reports indicating that the drug dilates intraocular arteries and augments intraocular vascular flow. These physiological responses to the agent apparently led to increased fluid entry into the anterior chamber. As such, the drug might have utility in patients with ocular hypotony resulting from insufficient AH formation. PMID:23562660

  18. Evaluation of anterior segment parameters in patients with pseudoexfoliation syndrome using Scheimpflug imaging

    Directory of Open Access Journals (Sweden)

    Alime Gunes

    2016-06-01

    Full Text Available ABSTRACT Purpose: To evaluate anterior segment parameters in patients with pseudoexfoliation syndrome (PXS using Scheimpflug imaging. Methods: Forty-three PXS patients and 43 healthy control subjects were included in this cross-sectional study. All participants underwent a detailed ophthalmologic examination. Anterior segment parameters were measured using a Scheimpflug system. Results: Considering the PXS and control groups, the mean corneal thicknesses at the apex point (536 ± 31 and 560 ± 31 µm, respectively, p=0.001, at the center of the pupil (534 ± 31 and 558 ± 33 µm, respectively, p=0.001, and at the thinnest point (528 ± 30 and 546 ± 27 µm, respectively, p=0.005 were significantly thinner in PXS patients. Visual acuity was significantly lower (0.52 ± 0.37 versus 0.88 ± 0.23, p<0.001 and axial length was significantly longer (23.9 ± 0.70 mm versus 23.2 ± 0.90 mm, p=0.001 in the PXS eyes than in the control eyes. There were no statistically significant differences in the mean values of keratometry, anterior chamber angle, anterior chamber depth, corneal volume, and anterior chamber volume between the PXS and control eyes. Conclusions: The patients with PXS had thinner corneas, worse visual acuity, and longer axial length compared with those in the healthy controls.

  19. Biometric analysis of pigment dispersion syndrome using anterior segment optical coherence tomography.

    Science.gov (United States)

    Aptel, Florent; Beccat, Sylvain; Fortoul, Vincent; Denis, Philippe

    2011-08-01

    To compare anterior chamber volume (ACV), iris volume, and iridolenticular contact (ILC) area before and after laser peripheral iridotomy (LPI) in eyes with pigment dispersion syndrome (PDS) using anterior segment optical coherence tomography (AS OCT) and image processing software. Cross-sectional study. Eighteen eyes of 18 patients with PDS; 30 eyes of 30 controls matched for age, gender, and refraction. Anterior segment OCT imaging was performed in all eyes before LPI and 1, 4, and 12 weeks after LPI. At each visit, 12 cross-sectional images of the AS were taken: 4 in bright conditions with accommodation (accommodation), 4 in bright conditions without accommodation (physiological miosis), and 4 under dark conditions (physiologic mydriasis). Biometric parameters were estimated using AS OCT radial sections and customized image-processing software. Anterior chamber volume, iris volume-to-length ratio, ILC area, AS OCT anterior chamber depth, and A-scan ultrasonography axial length. Before LPI, PDS eyes had a significantly greater ACV and ILC area than control eyes (PPigment dispersion syndrome eyes do not have an iris that is abnormally large, relative to the AS size, but have a weakly resistant iris that is stretched and pushed against the lens when there is a pressure difference across the iris. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  20. The effect of Nd:YAG laser treatment of posterior capsule opacification on anterior chamber depth and refraction in pseudophakic eyes

    Directory of Open Access Journals (Sweden)

    Khambhiphant B

    2015-03-01

    Full Text Available Bharkbhum Khambhiphant,1 Chayata Liumsirijarern,2 Piyada Saehout1 1Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, 2Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand Purpose: This was a prospective descriptive study to determine the changes in intraocular lens (IOL position after neodymium-doped yttrium–aluminum–garnet (Nd:YAG laser posterior capsulotomy by measuring anterior chamber depth (ACD and refraction, including the spherical equivalent (SE and cylinder. Materials and methods: Forty-seven pseudophakic eyes with posterior capsule opacification of 29 patients were included. Nd:YAG laser posterior capsulotomy was performed. Patients’ ACD and refraction were measured before the treatment, as well as after the treatment at 1 week and 3 months. IOLMaster® and an automated refractometer were used at the Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand. Results: There were no statistically significant differences in ACD and SE before and after laser treatment at 1 week and 3 months (repeated analysis of variance, P=0.582 and P=0.269, respectively. Both backward IOL movement (number [n]=29 and forward IOL movement (n=18 were found. Some changes in cylindrical refraction were found at 1 week, but decreased at 3 months after capsulotomy (baseline cylinder: -1.16; cylinder at 1 week and 3 months: -1.00 and -1.14, respectively; P=0.012. These changes were the same with one-piece and three-piece IOLs. Conclusion: Nd:YAG laser posterior capsulotomy did not significantly change ACD and SE. It led to cylinder change at 1 week after laser, but the effect decreased at 3 months. This effect was small and may not be clinically significant. Keywords: posterior capsule opacification, neodymium-doped yttrium–aluminum–garnet, anterior chamber depth, pseudophakia, refraction

  1. Anterior segment morphology and morphometry in selected reptile species using optical coherence tomography.

    Science.gov (United States)

    Rival, Franck; Linsart, Adeline; Isard, Pierre-François; Besson, Christian; Dulaurent, Thomas

    2015-01-01

    To provide new and original images of the anterior segment (AS) of the eye of selected Ophidian, Chelonian, and Saurian species and to compare the AS architecture among and within these three groups. 17 Saurians, 14 Ophidians, and 11 Chelonians with no concurrent systemic or eye disease were included in the study. Age, weight, nose-cloaca distance (NCD), and pupil shape were collected for each animal. The AS was examined by optical coherence tomography (OCT). After gross description of the appearance of the AS, the central and peripheral corneal thickness (CCT, PCT) and anterior chamber depth (ACD) were measured using the software provided with the OCT device. The ratio CCT/ACD was then calculated for each animal. Pupil shape was a vertical slit in all the crepuscular or nocturnal animals (except for 1 chelonian and 1 ophidian). Each group had its own particular AS architecture. Saurians had a regularly thin cornea with a flat anterior lens capsule and a deep anterior chamber. Ophidians had a thick cornea with a narrow anterior chamber due to a very anteriorly anchored spherical lens. The spectacle was difficult to identify in all ophidians except in Python molurus bivitattus in which it was more obvious. Chelonians displayed an intermediate architecture which more closely resembled the Saurian type than the Ophidian type. Despite grossly similar AS architecture, the three groups of reptiles in the study demonstrated differences that are suggestive of a link between anatomical disparities and variations in environment and lifestyle. © 2014 American College of Veterinary Ophthalmologists.

  2. Central corneal thickness and anterior chamber depth measurement by Sirius® Scheimpflug tomography and ultrasound

    Directory of Open Access Journals (Sweden)

    Jorge J

    2013-02-01

    Full Text Available J Jorge,1 JL Rosado,2 JA Díaz-Rey,1 JM González-Méijome11Clinical and Experimental Optometry Research Laboratory, Center of Physics (Optometry, School of Sciences, University of Minho, Braga, 2Opticlinic, Lisboa, PortugalBackground: The purpose of this study was to compare the accuracy of the new Sirius® Scheimpflug anterior segment examination device for measurement of central corneal thickness (CCT and anterior chamber depth (ACD with that of CCT measurements obtained by ultrasound pachymetry and ACD measurements obtained by ultrasound biometry, respectively.Methods: CCT and ACD was measured in 50 right eyes from 50 healthy subjects using a Sirius Scheimpflug camera, SP100 ultrasound pachymetry, and US800 ultrasound biometry.Results: CCT measured with the Sirius was 546 ± 39 µm and 541 ± 35 µm with SP100 ultrasound pachymetry (P = 0.003. The difference was statistically significant (mean difference 4.68 ± 10.5 µm; limits of agreement −15.8 to 25.20 µm. ACD measured with the Sirius was 2.96 ± 0.3 mm compared with 3.36 ± 0.29 mm using US800 ultrasound biometry (P < 0.001. The difference was statistically significant (mean difference −0.40 ± 0.16 mm; limits of agreement −0.72 to 0.07 mm. When the ACD values obtained using ultrasound biometry were corrected according to the values for CCT measured by ultrasound, the agreement increased significantly between both technologies for ACD measurements (mean difference 0.15 ± 0.16 mm; limits of agreement −0.16 to 0.45 mm.Conclusion: CCT and ACD measured by Sirius and ultrasound methods showing good agreement between repeated measurements obtained in the same subjects (repeatability with either instrument. However, CCT and ACD values, even after correcting ultrasound ACD by subtracting the CCT value obtained with either technology should not be used interchangeably.Keywords: Scheimpflug corneal tomography, ultrasound biometry, ultrasound pachymetry, limits of agreement

  3. Efficacy of goniosynechialysis for advanced chronic angle-closure glaucoma

    Directory of Open Access Journals (Sweden)

    Qing G

    2012-10-01

    Full Text Available Guoping Qing,1,2 Ningli Wang,1 Dapeng Mu11Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Lab, Beijing, China; 2State Key Laboratory of Brain and Cognitive Science, Institute of Biophysics, Chinese Academy of Sciences, Beijing, ChinaPurpose: To evaluate the intraocular pressure (IOP-lowering efficacy of goniosynechialysis (GSL for advanced chronic angle-closure glaucoma (CACG using a simplified slit-lamp technique.Patients and methods: Patients with CACG with one severely affected eye with best-corrected visual acuity below 20/200 and a mildly or functionally unaffected fellow eye were enrolled in this study. All patients underwent ophthalmologic examinations including measurement of visual acuity, best-corrected visual acuity, and IOP; biomicroscopy; specular microscopy; fundus examination; and gonioscopy followed by anterior chamber paracentesis and GSL for nasal peripheral anterior synechiae in the eye with severe CACG.Results: Thirty patients (18 men, 12 women were identified as having CACG with an initial mean IOP of 47.1 ± 6.7 mmHg (range 39–61 mmHg in the severely affected eye. One week after GSL, the mean IOP of the treated eyes decreased to 19.3 ± 2.8 mmHg (range 14–26 mmHg without antiglaucoma medication (average decrease 27.7 ± 6.5 mmHg; range 16–41 mmHg, which was significant (P < 0.00001 compared with baseline. After an average follow-up period of 36.6 ± 1.0 months (range 35–38 months, the mean IOP stabilized at 17.4 ± 2.2 mmHg (range 12–21 mmHg. The nasal angle recess did not close again in any one of the patients during the follow-up period. The average significant (P < 0.00001 decrease in corneal endothelial cell density in the treated eyes was 260 ± 183 cells/mm2 (range 191–328 cells/mm2.Conclusions: Anterior chamber paracentesis and GSL lowers IOP in advanced CACG, though it may lead to mild corneal endothelial cell loss

  4. Closed chamber globe stabilization and needle capsulorhexis using irrigation hand piece of bimanual irrigation and aspiration system

    Directory of Open Access Journals (Sweden)

    Rai Harminder K

    2005-08-01

    Full Text Available Abstract Background The prerequisites for a good capsulorhexis include a deep, well maintained anterior chamber, globe stabilization and globe manipulation. This helps to achieve a capsulorhexis of optimal size, shape and obtain the best possible position for a red glow under retroillumination. We report the use of irrigation handpiece of bimanual irrigation aspiration system to stabilize the globe, maintain a deep anterior chamber and manipulate the globe to a position of optimal red reflex during needle capsulorhexis in phacoemulsification. Methods Two side ports are made with 20 G MVR 'V' lance knife (Alcon, USA. The irrigation handpiece with irrigation on is introduced into the anterior chamber through one side port and the 26-G cystitome (made from 26-G needle is introduced through the other. The capsolurhexis is completed with the needle. Results Needle capsulorhexis with this technique was used in 30 cases of uncomplicated immature senile cataracts. 10 cases were done under peribulbar anaesthesia and 20 under topical anaesthesia. A complete capsulorhexis was achieved in all cases. Conclusion The irrigating handpiece maintains deep anterior chamber, stabilizes the globe, facilitates pupillary dilatation, and helps in maintaining the eye in the position with optimal red reflex during needle capsulorhexis. This technique is a safe and effective way to perform needle capsulorhexis.

  5. Insufficient evidence of benefit regarding mortality due to albumin substitution in HCC-free cirrhotic patients undergoing large volume paracentesis.

    Science.gov (United States)

    Kütting, Fabian; Schubert, Jens; Franklin, Jeremy; Bowe, Andrea; Hoffmann, Vera; Demir, Muenevver; Pelc, Agnes; Nierhoff, Dirk; Töx, Ulrich; Steffen, Hans-Michael

    2017-02-01

    Current guidelines for clinical practice recommend the infusion of human albumin after large volume paracentesis. After inspecting the current evidence behind this recommendation, we decided to conduct a systematic review and meta-analysis in order to address the effect of albumin on mortality and morbidity in the context of large volume paracentesis. We performed a comprehensive search of large databases and abstract books of conference proceedings up to March 15th 2016 for randomized controlled trials, testing the infusion of human albumin against alternatives (vs no treatment, vs plasma expanders; vs vasoconstrictors) in HCC-free patients suffering from cirrhosis. We analyzed these trials with regard to mortality, changes in plasma renin activity (PRA), hyponatremia, renal impairment, recurrence of ascites with consequential re-admission into hospital and additional complications. We employed trial sequential analysis in order to calculate the number of patients required in controlled trials to be able to determine a statistically significant advantage of the administration of one agent over another with regard to mortality. We were able to include 21 trials totaling 1277 patients. While the administration of albumin prevents a rise in PRA as well as hyponatremia, no improvement in strong clinical endpoints such as mortality could be demonstrated. Trial sequential analysis showed that at least 1550 additional patients need to be recruited into RCTs and analyzed with regard to this question in order to detect or disprove a 25% mortality effect. There is insufficient evidence that the infusion of albumin after LVP significantly lowers mortality in HCC-free patients with advanced liver disease. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  6. Corneal Collagen Cross-Linking Combined with an Artiflex Iris-Fixated Anterior Chamber Phakic Intraocular Lens Implantation in a Patient with Progressive Keratoconus

    Directory of Open Access Journals (Sweden)

    Sharif Hashmani

    2017-10-01

    Full Text Available We present here the case of a 24-year-old male who experienced progressive keratoconus and vision loss which adversely affected his ability to carry out everyday tasks. This landed him in the Hashmanis Hospital for consultation. He had a preoperative best corrected visual acuity of 6/12. He underwent multiple Oculus Pentacam examinations, which showed progressive keratoconus. Corneal collagen cross-linking (CXL was performed to stabilize his cornea and, subsequently, an Artiflex anterior chamber iris-fixated phakic intraocular lens (ACIF-PIOL was implanted to alleviate his refractive errors. The patient achieved a postoperative uncorrected visual acuity of 6/12. This report shows that CXL combined with ACIF-PIOL can be safe and effective in those with progressive keratoconus.

  7. Removal of intraocular foreign body in anterior chamber angle with prism contact lens and 23-gauge foreign body forceps.

    Science.gov (United States)

    Huang, Yan-Ming; Yan, Hua; Cai, Jin-Hong; Li, Hai-Bo

    2017-01-01

    To introduce a novel approach in removal of anterior chamber angle foreign body (ACFB) using a prism contact lens and 23-gauge foreign body forceps. Data of 42 eyes of 42 patients who had undergone removal of ACFB using a prism contact lens and 23-gauge foreign body forceps from January 2008 to October 2013 were collected and analyzed. Twenty eyes in group A received the conventional approach by using toothed forceps through corneal limbus incision, and 22 eyes in group B underwent the novel method through the opposite corneal limbus incision. The success rate of ACFB once removal was 75% (15/20) in group A, and 100% (22/22) in group B. The average operation time of group A was significantly longer compared with group B (34.9±9.88min vs 22.13±8.85min; P contact lens and 23-gauge foreign body forceps is a safer, more effective, and convenient technique compared with the conventional approach.

  8. Anterior segment optical coherence tomography changes with introduction and discontinuation of tamsulosin.

    Science.gov (United States)

    Al-Kharashi, Abdullah; Azimzadeh, Amir A; Leung, Jerry; Radomski, Sidney; Radomski, Lenny; Lam, Wai-Ching

    2016-01-01

    The aim of this study was to quantify changes and reversibility in pupil dilation and iris dilator muscle region thickness associated with introduction and subsequent discontinuation of tamsulosin in patients naïve to this drug with the aid of an anterior OCT system. The study was carried out on 7 patients (14 eyes) naïve to tamsulosin and with benign prostatic hypertrophy (BHP). Measurements taken by Vistante OCT were done pre- and post-dilation of the following: pupil size, iris dilator muscle region (DMR) thickness, sphincter muscle region (SMR) thickness, and anterior chamber depth. These measurement were taken at Day 0 (tamsulosin naive), Day 30 (after one month of tamsulosin, the treatment period) and day 60 (after one month of no tamsulosin, the discontinuation period). Post-dilation pupil diameter significantly increased during the discontinuation period ( P  = 0.047). Iris DMR thickness measurements post-dilation significantly decreased during treatment ( P  = 0.00044), discontinuation (0.00011), and combined periods ( P  = 0.000050). Anterior chamber depth measurements in post-dilation were significantly decreased during treatment ( P  = 0.0016), discontinuation ( P  = 0.017), and combined periods ( P  = 0.00022). Tamsulosin discontinuation effectively increases dilated pupil size, a measure that has been inversely linked to IFIS incidence pre-operatively. Decreased DMR thickness in this short term likely illustrates changes aside from atrophy, such as vascular changes. Decreased anterior chamber depths suggest aqueous humor production is decreased as well.

  9. Anterior segment sparing to reduce charged particle radiotherapy complications in uveal melanoma

    International Nuclear Information System (INIS)

    Daftari, Inder K.; Char, Devron H.; Verhey, Lynn J.; Castro, Joseph R.; Petti, Paula L.; Meecham, William J.; Kroll, Stewart; Blakely, Eleanor A.

    1997-01-01

    Purpose: The purpose of this investigation is to delineate the risk factors in the development of neovascular glaucoma (NVG) after helium-ion irradiation of uveal melanoma patients and to propose treatment technique that may reduce this risk. Methods and Materials: 347 uveal melanoma patients were treated with helium-ions using a single-port treatment technique. Using univariate and multivariate statistics, the NVG complication rate was analyzed according to the percent of anterior chamber in the radiation field, tumor size, tumor location, sex, age, dose, and other risk factors. Several University of California San Francisco-Lawrence Berkeley National Laboratory (LBNL) patients in each size category (medium, large, and extralarge) were retrospectively replanned using two ports instead of a single port. By using appropriate polar and azimuthal gaze angles or by treating patients with two ports, the maximum dose to the anterior segment of the eye can often be reduced. Although a larger volume of anterior chamber may receive a lower dose by using two ports than a single port treatment. We hypothesize that this could reduce the level of complications that result from the irradiation of the anterior chamber of the eye. Dose-volume histograms were calculated for the lens, and compared for the single and two-port techniques. Results: NVG developed in 121 (35%) patients. The risk of NVG peaked between 1 and 2.5 years posttreatment. By univariate and multivariate analysis, the percent of lens in the field was strongly correlated with the development of NVG. Other contributing factors were tumor height, history of diabetes, and vitreous hemorrhage. Dose-volume histogram analysis of single-port vs. two-port techniques demonstrate that for some patients in the medium and large category tumor groups, a significant decrease in dose to the structures in the anterior segment of the eye could have been achieved with the use of two ports. Conclusion: The development of NVG after

  10. [Iris abscess after bacterial endocarditis in a patient with leukaemia. Differential diagnosis].

    Science.gov (United States)

    Manrique Lipa, R; González Sánchez, E; Asencio Duran, M; Gonzalez-Peramato, P; Fonseca Santodomingo, A

    2014-04-01

    To report a case of iris abscess due to bacterial endocarditis. A 46-year-old male under diagnosis of promielocitic leukemia and endocarditis presented with decreased vision in left eye (OS). Ophthalmic exploration revealed iris abscess and hypopyon with fibrinous exudate in iris of the left eye and tyndall +1 in right eye (OD). Blood culture and anterior chamber paracentesis was positive for methicillin-sensitive Staphylococcus aureus and negative for blastic cells in citology. Treatment with systemic antibiotic was initiated with total resolution of inflammation. Iris abscess is an unusual septic focus in bacterial endocarditis. It is crucial to rule out an extramedullary metastasis in a patient with leukemia due to the general prognosis. Copyright © 2011 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  11. Repeatability and comparison of clinical techniques for anterior chamber angle assessment.

    Science.gov (United States)

    Campbell, Peter; Redmond, Tony; Agarwal, Rishi; Marshall, Lewis R; Evans, Bruce J W

    2015-03-01

    To assess the repeatability of gonioscopy, van Herick method and anterior segment Optical Coherence Tomography (AS-OCT) and determine the agreement between these techniques within a community optometry setting. Gonioscopy, van Herick method and AS-OCT imaging were performed by an optometrist on two occasions, 1 month apart, on 80 subjects aged over 40 years recruited from community optometry practices. Anterior segment images were captured with a spectral domain OCT (Topcon 3D OCT-2000; wavelength 840 nm) set to the Anterior Segment (AS) mode. Eyes were graded as open or occludable for each method. AS-OCT images from both visits were graded by a second optometrist masked to the gonioscopy and van Herick method results, and the visit on which the images were acquired. Cohen's kappa (κ) was used to describe the intra-observer repeatability. Likelihood ratios, sensitivity and specificity of van Herick method and AS-OCT were calculated, using gonioscopy as the reference standard. Measurements were obtained from 80 eyes of 80 subjects. In four cases, AS-OCT images were un-gradable due to difficulty in locating the scleral spur. The repeatability of gonioscopy was fair κ = 0.29, while that of the van Herick method (κ = 0.54) and AS-OCT (κ = 0.47) were somewhat better. The van Herick method showed good sensitivity (visit 1: 75%, visit 2: 69%) and high specificity (visit 1: 88%, visit 2: 96%). The sensitivity of AS-OCT was fair (visit 1: 46%, visit 2: 25%), but specificity was high (visit 1: 87%. visit 2: 89%). Intra-observer repeatability was better for van Herick method and for AS-OCT than for gonioscopy, despite the latter being considered the gold standard method. The van Herick method appeared to be more sensitive than AS-OCT when identifying eyes at risk of angle closure. A standalone anterior segment OCT with a longer wavelength laser could afford better visualisation of the angle, and might therefore be expected to enable the examiner to make more

  12. [Chamber Angle Assessment in Clinical Practice - A Comparison between Optical Coherence Tomography and Gonioscopy].

    Science.gov (United States)

    Mösler, M P; Werner, J U; Lang, G K

    2015-07-01

    In glaucoma the structures of the anterior chamber are important for classification, therapy, progression and prognosis. In this context anterior segment optical coherence tomography (AS-OCT) gains more relevance. This study compares AS-OCT with gonioscopy in diagnostic performance of chamber angle (CA) assessment. 104 consecutive subjects with glaucoma underwent AS-OCT imaging using the Visante OCT. RESULTS were compared to gonioscopic grading from patient history using the Shaffer system. In addition, anterior chamber depth (ACD) assessment using slitlamp examination was evaluated as a prognostic factor for chamber angle width (CAW) and verified by AS-OCT measurement. Average CAW was 29° (AS-OCT). 17 % of the CAs that were "wide" in gonioscopy (variance 5-55°), showed a "narrow" CA in AS-OCT. 35 % of the CAs that were "narrow" in gonioscopy (variance 0-39°) showed a "wide" CA in AS-OCT. ACD assessment using slitlamp examination is a good predictor for CAW. In this context the technique provides equal informative value as gonioscopy. In cases of "wide" ACDs it is even superior. The critical ACD for an increased risk of angle closure is 2.4 mm. Concerning the critical ACD (gonioscopy difficult or impossible, optical coherence tomography is an effective alternative to the gold standard and is to some extent even superior. Georg Thieme Verlag KG Stuttgart · New York.

  13. Effects of 1% cyclopentolate hydrochloride on anterior segment parameters obtained with Pentacam in young adults

    Directory of Open Access Journals (Sweden)

    Ceyhun Arici

    2014-08-01

    Full Text Available Purpose: To investigate the effects of topically applied 1% cyclopentolate hydrochloride on anterior segment parameters obtained with a Pentacam rotating Scheimpflug camera in healthy young adults. Methods: Anterior segment analyses of 25 eyes from 25 young adults (Group 1, before and after 45 min of 1% cyclopentolate hydrochloride application, were performed. For a control group (cycloplegia-free, Group 2, 24 eyes of 24 age- and sex-matched healthy cases were evaluated twice at 45 min intervals. The results obtained from the groups were compared statistically. Results: The mean ages of the groups were 23.04 ± 3.42 (range, 18-29 and 22.4 ± 2.05 (range, 18-27 years for Groups 1 and 2, respectively (p=0.259. In Group 1, measurements between the two analyses were significantly different for the values of anterior chamber depth (ACD, anterior chamber angle (ACA, and anterior chamber volume (ACV (p<0.05, whereas no statistical difference was found for the central corneal thickness (CCT and keratometry (K1, K2 measurements. In Group 2, none of these parameters were statistically different between the two analyses. Conclusions: Topically applied 1% cyclopentolate hydrochloride caused an increase in the ACD and ACV values, and a decrease in the ACA value. However, it had no significant effect on the CCT and keratometry measurements. It is important to consider these effects when using the Pentacam device on young adults with cycloplegia and when applying it for various reasons.

  14. Multiaxial tomography of heart chambers by gated blood-pool emission computed tomography using a rotating gamma camera

    International Nuclear Information System (INIS)

    Tamaki, N.; Mukai, T.; Ishii, Y.; Yonekura, Y.; Yamamoto, K.; Kadota, K.; Kambara, H.; Kawai, C.; Torizuka, K.

    1983-01-01

    Fifteen patients and three volunteers underwent radionuclide blood-pool cardiac studies with electrocardiographic gating. Following conventional planar-gated imaging (anterior and left anterior oblique projections), emission computed tomography (ECT), using a rotating gamma camera, was performed.A series of transaxial tomograms of the cardiac chambers was obtained. The left ventricular short-axis plane, long-axis plane, and four-chamber-view plane were then reorganized; each chamber was visualized separately. Compared to gated planar imaging, this technique showed regional asynergy more clearly in patients with myocardial infarction and demonstrated dilatation of the atria and ventricles more accurately in patients with an atrial septal defect and valvular heart diseases. In addition, when a section of the heart is otained at any angle with gated blood pool ECT, three-dimensional assessment of cardiac chambers in motion is more precise; mutual superimposition becomes unnecessary

  15. [Are biometric parameters of anterior segment of the eyeball influenced by type 2 diabetes?].

    Science.gov (United States)

    Dmuchowska, Diana A; Kraśnicki, Paweł; Mariak, Zofia

    2012-01-01

    To answer the question whether biometric parameters of anterior segment of the eyeball are influenced by type 2 diabetes, at the stage when the lens is still transparent, so before cataract development. Fifty subjects (28 women and 22 men), at the age of 63.3 +/- 11.3 years were enrolled in this prospective study. They were divided in 2 groups: patients with type 2 diabetes (24 subjects) and analogous age group in good general health - control group (26 subjects). None of the tested individuals presented lens opacities. The planned biometric measurements included: central corneal thickness, anterior chamber depth and axial lens thickness. The data were statistically analyzed. There was no difference between the groups of both proven and potential parameters that are associated with biometric measurements of the anterior segment of the eyeball, such as: gender, age, smoking and axial length of the eye. In diabetic patients, as opposed to the subjects in the control group, statistically significantly increased lens thickness (4.78 +/- 0.50 mm vs 4.43 +/- 0.50; p = 0.016), central corneal thickness (561.5 +/- 31.6 microm vs 542.2 +/- 35.2; p = 0.047), and the tendency for shallow anterior chamber (3.06 +/- 0.40 mm vs 3.22 +/- 0.38; p = 0.159), were observed. In patients with diabetes there was no association of the biometric parameters values with the duration of diabetes and presence of diabetic retinopathy. Type 2 diabetes contributes to increased axial corneal and lens thickness at the stage when the lens is transparent, albeit it does not significantly affect anterior chamber depth.

  16. Impact of the Femtosecond Laser in Line with the Femtosecond Laser-Assisted Cataract Surgery (FLACS) on the Anterior Chamber Characteristics in Comparison to the Manual Phacoemulsification.

    Science.gov (United States)

    Pahlitzsch, Milena; Torun, Necip; Pahlitzsch, Marie Luise; Klamann, Matthias K J; Gonnermann, Johannes; Bertelmann, Eckart; Pahlitzsch, Thomas

    2017-01-01

    To assess the alterations of the anterior chamber conditions including laser flare photometry after femtosecond laser-assisted cataract surgery (FLACS) compared to the manual phacoemulsification. Data of n=70 FLACS (mean age 67.2 ± 8.9 years) and n=40 manual phacoemulsification (mean age 69.5 ± 9.6 years) were analyzed. The procedures were performed by LenSx Alcon, USA, and Alcon Infiniti Vision System, USA. The following parameters were recorded: laser flare photometry (Kowa FM 700, Japan), anterior chamber (AC) depth, AC volume, AC angle (Pentacam, Oculus Inc., Germany), lens density, pupil diameter, endothelial cell count and pachymetry. The analysis was performed preoperatively, immediately after femtosecond laser procedure and one day postoperatively. Between FLACS and the phaco control group, there was a significant difference in the AC depth (p=0.023, 3.77 mm vs. 4.05 mm) one day postoperatively. The AC angle (p=0.016) showed a significant difference immediately after the femto laser treatment. The central and thinnest pachymetry and endothelial cell count did not show a significant difference between the two study cohorts (p=0.165, p=0.291, p=0.979). The phaco cohort (n=40) demonstrated a non-statistically significant difference in the flare photometry of 15.80 photons/ms one postoperative day compared to the FLACS group 26.62 photons/ms (p=0.322). In this study population, no evidence for an additive damage caused by the use of the femtosecond laser was demonstrated. Furthermore, no increase in the central and thinnest corneal thickness and no increased endothelial cell loss was demonstrated by the laser energy.

  17. The anterior chamber angle width in adults in a tertiary eye hospital ...

    African Journals Online (AJOL)

    2011-03-25

    Mar 25, 2011 ... had visual acuity assessment, visual field analysis, ophthalmoscopy, intraocular pressure measurement, ... Peripheral anterior synechiae were observed in three eyes. ..... The high incidence of narrow angles with the near.

  18. Phakic Intraocular Lens Implantation: Refractive Outcome and Safety in Patients with Anterior Chamber Depth between 2.8 and 3.0 versus ≥3.0 mm.

    Science.gov (United States)

    Guerra, Marta G; Silva, Andreia M M; Marques, Sara H M; Melo, Sofia H; Póvoa, João A; Lobo, Conceição; Murta, Joaquim Neto

    2017-01-01

    To compare endothelial cell (EC) variation after anterior chamber phakic intraocular lens (AC-pIOL) implantation in highly myopic patients with a preoperative anterior chamber depth (ACD) between 2.8 and 3.0 versus ≥3.0 mm. A total of 280 eyes submitted to primary AC-pIOL implantation were analyzed. Pre- and postoperative values for uncorrected distance visual acuity, corrected distance visual acuity, spherical equivalent, ACD (endothelial surface), and EC count were collected. The eyes were divided into 2 groups: group A - ACD between 2.8 and 3.0 mm; group B - ACD ≥3.0 mm. Mean global EC loss (ECL) and loss for each ACD group, according to pIOL type, were analyzed. Significant improvement of the spherical equivalent (-11.38 ± 4.57 vs. -0.49 ± 0.79; p = 0.000) and a significant decrease in EC density (2,810.95 ± 343.88 vs. 2,584.09 ± 374.88 cells/mm2; p = 0.000) were noted. The mean annual ECL was -2.19 ± 3.97%. Regarding group A (n = 80), a mean annual ECL of -2.06 ± 3.88% was registered, higher for the Acrysof Cachet® subtype, while group B (n = 200) showed -2.25 ± 4.01% ECL, higher for the Verisyse® subtype. There was no significant difference between the groups (p = 0.96). AC-pIOL implantation significantly improves the spherical equivalent in myopic patients. The mean annual ECL after pIOL implantation was higher in the larger ACD group, but this value was not statistically significant. A 2.8-mm ACD value seems to be a safe cutoff for AC-pIOL implantation. © 2017 S. Karger AG, Basel.

  19. [Lens exchange for subluxation of posterior chamber lenses implanted in the capsular bag or in the ciliary sulcus].

    Science.gov (United States)

    Stürmer, J

    2013-04-01

    There are an increasing number of patients with decreased vision due to dislocated posterior chamber lenses, with pseudoexfoliation being the main risk factor. Various techniques for refixation of the subluxated posterior chamber IOL have been described. Experience with our technique of IOL-explantation, anterior vitrectomy and implantation of an Artisan anterior chamber lens are presented. In a retrospective study design all lens exchanges with implantation of an Artisan anterior chamber lens performed between 2003 and 2012 are analyzed. The study included 65 eyes of 61 patients (age 79.6 ± 9.2 years: 43-98). The majority of eyes (46/65; 70.8%) had Sundown Syndrome (late in-the-bag intraocular lens dislocation), in 19 eyes the posterior chamber lens was implanted primary or secondary into the ciliary sulcus. In the 46 eyes with Sundown Syndrome cataract surgery with implantation of a posterior chamber lens in the capsular bag was performed 7.4 ± 3.7 (1-22) years before subluxation within the bag. Pseudoexfoliation was the main risk factor in 42/46 (91.2%) of these eyes. A capsular tension ring (CTR) was implanted during cataract surgery in 34/46 (73.9%) eyes. The 34 IOLs with a CTR luxated significantly earlier (p IOLs without a CTR (6.6 ± 3.6 years; median 5.8 vs. 9.4 ± 3.1 years; median 9.2). The average visual gain was 0.2 logMAR in the group of luxated capsular bag lenses and 0.12 logMAR in the group of luxated sulcus lenses. Postoperative IOP decompensation was seen in 17/65 (26.2%) eyes (requiring IOP-lowering surgery in 8 eyes), 7 eyes developed corneal decompensation, 5 eyes had central retinal vein occlusion and one eye developed postoperative endophthalmitis. Lens exchange with implantation of an Artisan anterior chamber lens has become a routine procedure to improve vision in patients with subluxated IOLs. Postoperative IOP decompensation and vascular problems are the major complications. Georg Thieme Verlag KG Stuttgart · New York.

  20. Changes in intraocular pressure and anterior segment morphometry after uneventful phacoemulsification cataract surgery.

    LENUS (Irish Health Repository)

    Dooley, I

    2012-02-01

    PURPOSE: To study changes in anterior segment morphometry after uneventful phacoemulsification cataract surgery, and to investigate whether there is a relationship between any observed changes and intraocular pressure (IOP) reduction after the procedure. METHODS: The anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), central corneal thickness (CCT), and IOP were measured in 101 non-glaucomatous eyes before and after uneventful phacoemulsification cataract surgery. RESULTS: After cataract surgery, the mean ACD, ACV, and ACA values increased by 1.08 mm, 54.4 mm(3), and 13.1 degrees , respectively, and the mean IOP (corrected for CCT) decreased by 3.2 mm Hg. The predictive value of a previously described index (preoperative ACD\\/preoperative IOP (corrected for CCT) or CPD ratio) for IOP (corrected for CCT) reduction after cataract surgery was confirmed, reflected in an r(2) value of 23.3% between these two parameters (P<0.001). Other indices predictive of IOP reduction after cataract surgery were also identified, including preoperative IOP\\/preoperative ACV and preoperative IOP\\/preoperative ACA, reflected in r(2) values of 13.7 and 13.7%, respectively (P<0.001 and P<0.001, respectively). CONCLUSIONS: Our study confirms the predictive value of the CPD ratio for IOP reduction after cataract surgery, and may contribute to the decision-making process in patients with glaucoma or ocular hypertension. Furthermore, two novel indices of preoperative parameters that are predictive for IOP reduction after cataract surgery were identified, and enhance our understanding of the mechanisms underlying IOP changes after this procedure.

  1. Clinical research of phacoemulsification with posterior chamber intraocular lens implantation for glaucoma with different goniosynechia ranges

    Directory of Open Access Journals (Sweden)

    Qing-Yu Li

    2016-02-01

    Full Text Available AIM:To study the effect of phacoemulsification with posterior chamber intraocular lens implantation to treat glaucoma with different angle-closure range, which may provide a better way to treat the angle-closure glaucoma.METHODS:There were 47 cases(54 eyeswith angle-closure glaucoma, and all of them underwent phacoemulsification and posterior chamber intraocular lens implantation. According to the range of goniosynechia, these patients were divided into three groups:the eyes with the range of goniosynechia≤1/2 were group A(13 eyes; the eyes with 1/23/4 were group C(23 eyes. We observed the status of anterior chamber angle and the intraocular pressure(IOPof the three groups at 2wk after operations. RESULTS:Compared to the preoperative condition, the IOP of the three groups at 2wk after operations decreased significantly. The IOP reductions of group B and C were more significant than that of group A, and the differences were significant(PPP3/4 appeared in group B; in group C, there were 5 eyes with goniosynechia>3/4, 1 eye with disappeared anterior chamber, 3 eyes with corneal edema, 1 eye with choroidal hemorrhage. The differences of postoperative complication rate among the three groups was statistically significant(PPCONCLUSION:For patients with angle closure glaucoma who have mild to moderate goniosynechia, phacoemulsification with posterior chamber intraocular lens implantation is an effective way. After operations, their closed anterior angle reopened. But to the patients with severe adhesions, there are more complications after operations, especially the glaucoma may reoccur.

  2. Relationship between intraocular pressure and angle configuration: an anterior segment OCT study.

    Science.gov (United States)

    Chong, Rachel S; Sakata, Lisandro M; Narayanaswamy, Arun K; Ho, Sue-Wei; He, Mingguang; Baskaran, Mani; Wong, Tien Yin; Perera, Shamira A; Aung, Tin

    2013-03-05

    To assess the relationship between intraocular pressure (IOP) and anterior chamber angle (ACA) configuration as assessed by gonioscopy and anterior segment optical coherence tomography (AS-OCT). A total of 2045 subjects aged 50 years and older, were recruited from a community clinic and underwent AS-OCT, Goldmann applanation tonometry, and gonioscopy. A quadrant was classified as closed on gonioscopy if the posterior trabecular meshwork could not be seen. A closed quadrant on AS-OCT was defined by the presence of any contact between the iris and angle wall anterior to the scleral spur. Customized software (Zhongshan Angle Assessment Program, Guangzhou, China) was used to measure AS-OCT parameters on AS-OCT scans, including anterior chamber depth, area, and volume; iris thickness (IT) and curvature; lens vault; angle opening distance; and trabecular-iris space area. IOP values were adjusted for age, sex, diabetes and hypertension status, body mass index, central corneal thickness, and presence of peripheral anterior synechiae. Mean age of study subjects was 63.2 ± 8.0 years, 52.6% were female, and 89.4% were Chinese. Mean IOP was 14.8 ± 2.4 mm Hg (range 826). IOP (mean ± SE) increased with number of quadrants with gonioscopic angle closure (none: 14.6 ± 0.2; one: 14.7 ± 0.3; two: 15.0 ± 0.3; three: 15.0 ± 0.3; four: 15.6 ± 0.3 mm Hg; P gonioscopy, with increasing IOP.

  3. Intraocular eyelashes and iris cyst in anterior chamber following penetrating eye injury: a case report

    Directory of Open Access Journals (Sweden)

    Sahu S

    2017-03-01

    Full Text Available Sabin Sahu,1 Lila Raj Puri,1 Sanjay Kumar Singh2 1Department of Ophthalmology, Sagarmatha Choudhary Eye Hospital, Lahan, Siraha, 2Department of Ophthalmology, Biratnagar Eye Hospital, Biratnagar, Nepal Background: The presence of intraocular eyelashes following penetrating eye injury or ocular surgery is relatively uncommon. The response of the eye to intraocular eyelashes is variable. The eyelash may be symptomatic or may remain asymptomatic for long periods. Objective: We report a case with two intraocular eyelashes and an iris cyst after 2 years of asymptomatic period following penetrating eye injury. Case presentation: A 24-year-old male presented with decreased vision in the left eye which he had noticed for the previous 2 weeks. His visual acuity was 6/6 in the right eye and 6/18 in the left eye, improving to 6/9 with -2.5 DC × 140° correction. The intraocular pressure was 12 mmHg in both eyes. On slit-lamp examination, the left eye showed 8 mm linear peripheral corneal opacity nasally, two eyelashes in the superior anterior chamber, and an iris cyst measuring 4 mm × 4 mm in the superior iris. The right eye was normal. Dilated fundus examination of both eyes was normal. The eyelashes and cyst were removed surgically. There were no complications during the 3-month follow-up period. Conclusion: Intraocular implantation of eyelashes following penetrating eye injury can remain asymptomatic for long periods; however, late development of iris cyst may occur. Keywords: intraocular eyelashes, iris cyst, penetrating eye injury

  4. Regulation of anterior chamber drainage by bicarbonate-sensitive soluble adenylyl cyclase in the ciliary body.

    Science.gov (United States)

    Lee, Yong S; Tresguerres, Martin; Hess, Kenneth; Marmorstein, Lihua Y; Levin, Lonny R; Buck, Jochen; Marmorstein, Alan D

    2011-12-02

    Glaucoma is a leading cause of blindness affecting as many as 2.2 million Americans. All current glaucoma treatment strategies aim to reduce intraocular pressure (IOP). IOP results from the resistance to drainage of aqueous humor (AH) produced by the ciliary body in a process requiring bicarbonate. Once secreted into the anterior chamber, AH drains from the eye via two pathways: uveoscleral and pressure-dependent or conventional outflow (C(t)). Modulation of "inflow" and "outflow" pathways is thought to occur via distinct, local mechanisms. Mice deficient in the bicarbonate channel bestrophin-2 (Best2), however, exhibit a lower IOP despite an increase in AH production. Best2 is expressed uniquely in nonpigmented ciliary epithelial (NPE) cells providing evidence for a bicarbonate-dependent communicative pathway linking inflow and outflow. Here, we show that bicarbonate-sensitive soluble adenylyl cyclase (sAC) is highly expressed in the ciliary body in NPE cells, but appears to be absent from drainage tissues. Pharmacologic inhibition of sAC in mice causes a significant increase in IOP due to a decrease in C(t) with no effect on inflow. In mice deficient in sAC IOP is elevated, and C(t) is decreased relative to wild-type mice. Pharmacologic inhibition of sAC did not alter IOP or C(t) in sAC-deficient mice. Based on these data we propose that the ciliary body can regulate C(t) and that sAC serves as a critical sensor of bicarbonate in the ciliary body regulating the secretion of substances into the AH that govern outflow facility independent of pressure.

  5. Evaluation of the anterior chamber angle in Asian Indian eyes by ultrasound biomicroscopy and gonioscopy.

    Science.gov (United States)

    Kaushik, Sushmita; Jain, Rajeev; Pandav, Surinder Singh; Gupta, Amod

    2006-09-01

    To compare the ultrasound biomicroscopic measurement of the anterior chamber angle in Asian Indian eyes, with the angle width estimated by gonioscopy. Patients with open and closed angles attending a glaucoma clinic were recruited for the study. Temporal quadrants of the angles of patients were categorized by gonioscopy as Grade 0 to Grade 4, using Shaffer's classification. These angles were quantified by ultrasound biomicroscopy (UBM) using the following biometric characteristics: Angle opening distance at 250 micro (AOD 250) and 500 micro (AOD 500) from the scleral spur and trabecular meshwork-ciliary process distance (TCPD). The angles were further segregated as "narrow angles" (Schaffer's Grade 2 or less) and "open angles" (Schaffer's Grade 3 and 4). The UBM measurements were computed in each case and analyzed in relation to the gonioscopic angle evaluation. One hundred and sixty three eyes of 163 patients were analyzed. One hundred and six eyes had "narrow angles" and 57 eyes had "open angles" on gonioscopy. There was a significant difference among the mean UBM measurements of each angle grade estimated by gonioscopy (P gonioscopy grades was significant at the 0.01 level. The mean AOD 250, AOD 500 and TCPD in narrow angles were 58+/-49 micro, 102+/-84 micro and 653+/-124 respectively, while it was 176+/-47 micro, 291+/-62 micro and 883+/-94 micro in eyes with open angles (P gonioscopy correlated significantly with the angle dimensions measured by UBM. Gonioscopy, though a subjective test, is a reliable method for estimation of the angle width.

  6. Outcomes of iris-claw anterior chamber versus iris-fixated foldable intraocular lens in subluxated lens secondary to Marfan syndrome.

    Science.gov (United States)

    Hirashima, Denise E; Soriano, Eduardo S; Meirelles, Rodrigo L; Alberti, Gustave N; Nosé, Walton

    2010-08-01

    To compare the outcome of phacoemulsification using 2 different iris-fixation techniques for intraocular lens (IOL) replacement, a foldable posterior chamber IOL (PCIOL; AcrySof MA60AC, Alcon Laboratories Inc, Fort Worth, TX) and an iris-claw anterior chamber IOL (ACIOL; Artisan, Ophtec BV), for treatment of subluxated lenses in patients with Marfan syndrome (MFS). Randomized, controlled trial. A total of 31 eyes of 16 patients with subluxated lenses associated with MFS and a preoperative corrected visual acuity (CVA) IOL type. Preoperative and postoperative ophthalmologic examination, optical coherence tomography, and endothelial cell counts were performed. We recorded CVA results at 3, 6, and 12 months, complications, endothelial cell loss, and central retinal thickness. In the iris-fixated PCIOL group, CVA was significantly improved at 3 (P = 0.011; n = 16), 6 (P = 0.006; n = 16), and 12 months (P = 0.002; n = 16). In the iris-claw ACIOL group, CVA was significantly improved at 3 (P = 0.001; n=15), 6 (P = 0.001; n = 15), and 12 months (P = 0.009; n = 12). The CVA results did not differ significantly between groups. Dislocation of the IOL occurred in 3 of 16 (18.75%) eyes in the PCIOL group. Retinal detachment occurred in 3 eyes (2 in the PCIOL group and 1 in the ACIOL group) and was successfully repaired. Postoperative foveal tomograms in both groups revealed a decrease in the mean foveal thickness (MFT; IOL dislocation tended to occur more frequently in the iris-fixated PCIOL group, the difference was not significant. At 6 months postoperatively, all study patients tended to have a thinner MFT. None of the patients in either group developed cystoid macular edema. Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  7. Bilateral spontaneous dislocation of posterior chamber intraocular lens in a patient with gyrate atrophy

    Directory of Open Access Journals (Sweden)

    Michael Kinori

    2012-01-01

    Full Text Available We report a patient with gyrate atrophy, a rare metabolic disease, who had bilateral late spontaneous posterior dislocation of in-the-bag posterior chamber intraocular lens (PCIOL. He underwent pars plana vitrectomy, PCIOL retrieval and anterior chamber intraocular lens implantation in both eyes. This report may imply that patients with gyrate atrophy are at risk for spontaneous dislocation of intraocular lenses.

  8. A Novel Method of Quantitative Anterior Chamber Depth Estimation Using Temporal Perpendicular Digital Photography.

    Science.gov (United States)

    Zamir, Ehud; Kong, George Y X; Kowalski, Tanya; Coote, Michael; Ang, Ghee Soon

    2016-07-01

    We hypothesize that: (1) Anterior chamber depth (ACD) is correlated with the relative anteroposterior position of the pupillary image, as viewed from the temporal side. (2) Such a correlation may be used as a simple quantitative tool for estimation of ACD. Two hundred sixty-six phakic eyes had lateral digital photographs taken from the temporal side, perpendicular to the visual axis, and underwent optical biometry (Nidek AL scanner). The relative anteroposterior position of the pupillary image was expressed using the ratio between: (1) lateral photographic temporal limbus to pupil distance ("E") and (2) lateral photographic temporal limbus to cornea distance ("Z"). In the first chronological half of patients (Correlation Series), E:Z ratio (EZR) was correlated with optical biometric ACD. The correlation equation was then used to predict ACD in the second half of patients (Prediction Series) and compared to their biometric ACD for agreement analysis. A strong linear correlation was found between EZR and ACD, R = -0.91, R 2 = 0.81. Bland-Altman analysis showed good agreement between predicted ACD using this method and the optical biometric ACD. The mean error was -0.013 mm (range -0.377 to 0.336 mm), standard deviation 0.166 mm. The 95% limits of agreement were ±0.33 mm. Lateral digital photography and EZR calculation is a novel method to quantitatively estimate ACD, requiring minimal equipment and training. EZ ratio may be employed in screening for angle closure glaucoma. It may also be helpful in outpatient medical clinic settings, where doctors need to judge the safety of topical or systemic pupil-dilating medications versus their risk of triggering acute angle closure glaucoma. Similarly, non ophthalmologists may use it to estimate the likelihood of acute angle closure glaucoma in emergency presentations.

  9. Comparison of anterior chamber depths measured using the Pentacam, the IOLMaster, and ultrasound pachymetry

    Directory of Open Access Journals (Sweden)

    Jing Zhang

    2015-08-01

    Full Text Available AIM: To investigate and compare anterior chamber depths(ACDsmeasured using the Pentacam, the IOLMaster, and ultrasound pachymetry(US.METHODS: The present study was observational in nature. ACDs were measured in 138 eyes of 69 myopic patients, by the same operator, using the Pentacam, the IOLMaster, and US. We assessed the agreement among the three methods using Bland-Altman plots. The repeatability among the three methods was evaluated by within-subject standard deviation. RESULTS: The means±SDs of ACDs measured using the Pentacam, the IOLMaster, and US were 3.77±0.24, 3.73±0.23, and 3.69±0.22mm respectively. Bland-Altman analysis showed that Pentacam and IOLMaster data were in good agreement(CoA, 0.04mm; LoA,0.05 to 0.13mm, as were US and IOLMaster data(CoA, 0.04mm; LoA, 0.17 to 0.08mm, but the Pentacam ACD values were slightly greater than the US figures(CoA, 0.08mm; LoA, 0.06 to 0.22mm. Measurements of the ACD with the three devices also showed high repeatability(Sw=0.03, 0.02, and 0.03; 2.77 Sw=0.08, 0.06, and 0.08, respectively. The three depth estimates were positively correlated(r=0.946, 0.987, and 0.951; PCONCLUSION: Measurement of ACDs using the Pentacam, the IOLMaster, and US showed good agreement and repeatability. The Pentacam and IOLMaster ACDs, and the IOLMaster and US ACDs, agreed reasonably well, but agreement between the Pentacam and US data was poorer. However, both the absolute differences and the coefficients of variation were small, and the observed variability was likely not clinically significant.

  10. Cataract Surgery in Anterior Megalophthalmos: A Review

    Science.gov (United States)

    GALVIS, Virgilio; TELLO, Alejandro; M. RANGEL, Carlos

    2015-01-01

    Anterior megalophthalmos is characterized by megalocornea associated with a very broad anterior chamber and ciliary ring elongation. It is also called X-linked megalocornea. It is accompanied by early development of cataracts, zonular anomalies, and, rarely, vitreoretinal disorders. Subluxation of a cataract can occur in cataract surgery because of zonular weakness. In addition, in most patients, standard intraocular lens (IOL) decentration is a risk because of the enlarged sulcus and capsular bag. These unique circumstances make cataract surgery challenging. To date, several approaches have been developed. Implantation of a retropupillary iris-claw aphakic intraocular lens may be a good option because it is easier than suturing the IOL and can have better and more stable anatomic and visual outcomes, compared to other techniques. PMID:27350950

  11. Vitrectorhexis and lens aspiration with posterior chamber intraocular lens implantation in spherophakia.

    Science.gov (United States)

    Al-Haddad, Christiane; Khatib, Lama

    2012-07-01

    We describe a technique that uses the vitrector to perform successful lens aspiration and posterior chamber intraocular lens (IOL) implantation in children with spherophakia and anterior lens subluxation. After an anterior chamber maintainer is placed, the ocutome is introduced through a limbal incision to perform a circular vitrectorhexis to avoid excessive manipulation of the unstable lens followed by gentle cortex aspiration. A foldable IOL is injected into the sulcus (3-piece IOL) or bag (1-piece IOL) if the capsule is sufficiently stable. Through a pars plana incision, the ocutome is then used to perform a posterior capsulotomy to prevent late posterior capsule opacification. In our patient, sulcus IOL placement was more stable than in-the-bag placement. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Abdominal stab wound protocol: prospective study documents applicability for widespread use.

    Science.gov (United States)

    Rosemurgy, A S; Albrink, M H; Olson, S M; Sherman, H; Albertini, J; Kramer, R; Camps, M; Reiss, A

    1995-02-01

    Traditionally, stab wounds violating the abdominal wall fascia led to exploratory celiotomy that was often nontherapeutic. In an attempt to limit the number of nontherapeutic celiotomies (NTC), we devised a protocol to prospectively study stab wounds violating the anterior abdominal wall fascia. Through protocol, abdominal stab wounds were explored in stable adults. If the anterior fascia was violated, paracentesis and, if necessary, peritoneal lavage was undertaken in the absence of previous abdominal surgery. If evisceration was noted, it was reduced and the patient lavaged. Fascial penetration was noted in 72 patients. 46 patients underwent celiotomy: because of shock/peritonitis in 8 (2 NTC), fascial penetration with a history of previous celiotomy in 7 (5 NTC), positive paracentesis in 20 (5 NTC), or positive lavage in 10 (4 NTC). One patient underwent late celiotomy without ill-effect after a negative lavage because she subsequently developed fever and localized peritonitis (ice pick injury to cecum). Eleven patients had evisceration; nine underwent celiotomy. Patients with abdominal stab wounds can be selectively managed safely. More than one-third with fascial penetration, some with evisceration, avoided exploration. Only one patient underwent delayed celiotomy and did so without detriment. Nontherapeutic celiotomy rates were highest in patients with previous abdominal surgery who, thereby, could not undergo paracentesis/lavage; excluding these patients, the nontherapeutic celiotomy rate was 17% (11/65) for those with fascial penetration.

  13. Reverse pupillary block after implantation of a scleral-sutured posterior chamber intraocular lens: a retrospective, open study.

    Science.gov (United States)

    Bang, Seung Pil; Joo, Choun-Ki; Jun, Jong Hwa

    2017-03-29

    To report the clinical features of patients with reverse pupillary block (RPB) after scleral-sutured posterior chamber intraocular lens (PC IOL) implantation and biometric changes after laser peripheral iridotomy (LPI). Eight patients attending our hospital's ophthalmology outpatient clinic, who developed RPB after implantation of a scleral-sutured PC IOL due to subluxation of the crystalline lens or IOL, were investigated in this retrospective, observational study. Preoperative evaluations showed angle pigmentation in all cases and iridodonesis in 2 cases. Two subjects had used an α 1A -adrenoceptor antagonist for benign prostatic hyperplasia. Pars plana or anterior partial vitrectomy was performed in all cases. All eyes showed an extremely deep anterior chamber, a concave iris configuration, and contact between the IOL optic and the iris at the pupillary margin. Pupil capture was detected in 2 cases. The mean (± SD) anterior chamber angle (ACA) was 89.91 ± 10.06°, and the anterior chamber depth (ACD) was 4.42 ± 0.16 mm before LPI. After LPI, the iris immediately became flat with a decreased ACA (51.70 ± 2.59°; P = 0.018) and ACD (4.14 ± 0.15 mm; P = 0.012). After LPI, the intraocular pressure decreased from 19.75 ± 3.77 mmHg to 15.63 ± 4.30 mmHg (P = 0.011), and the spherical equivalent decreased from -0.643 ± 0.385 D to - 0.875 ± 0.505 D (P = 0.016). Concomitant vitrectomy, angle pigmentation, and iridodonesis may be risk factors for RPB after scleral-sutured PC IOL implantation. LPI is effective for relieving the RPB.

  14. Anterior and posterior ocular biometry in healthy Chinese subjects: data based on AS-OCT and SS-OCT.

    Directory of Open Access Journals (Sweden)

    Wenbin Huang

    Full Text Available To measure the anterior and posterior ocular biometric characteristics concurrently and to determine the relationship between the iris and choroid in healthy Chinese subjects.A total of 148 subjects (270 eyes were enrolled in this cross-section study. The anterior and posterior ocular biometric characteristics were measured simultaneously by anterior segment optical coherence tomography (AS-OCT and swept-source optical coherence tomography (SS-OCT.Compared with male eyes, female eyes had narrower anterior biometric parameters that presented with smaller anterior segment parameters [including anterior chamber depth (ACD, width (ACW, area (ACA, and volume (ACV; (all p<0.001], narrower anterior chamber angle parameters [including angle opening distance (AOD750, trabecular-iris space area (TISA750, and angle recess area (ARA; (all p<0.001], higher iris curvature (ICURV (p = 0.003, and larger lens vaults (LV (p = 0.019. These anterior ocular biometric parameters were correlated with increasing age (p<0.01. Iris thickness (IT750 and iris area (IAREA were associated with age, ACW, and pupil diameter (all p<0.05, while choroidal thickness (CT was associated with age, gender, and axial length (all p<0.05. Univariate regression analysis showed that greater CT was significantly associated with smaller IAREA (p = 0.026.Compared with male eyes, female eyes had narrower anterior biometric parameters that correlated with increasing age, which would be helpful in explaining the higher prevalence of angle closure rates in the female gender and in aging people. Increased CT might be associated with smaller iris area; however, this possibility needs to be investigated in future studies before this conclusion is made.

  15. Evaluation of Descemet’s Membrane Detachment Using Anterior Segment Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Halil Hüseyin Çağatay

    2014-10-01

    Full Text Available We report the use of anterior segment optical coherence tomography (ASOCT in Descemet’s membrane detachment (DMD. A patient who developed DMD after uneventful cataract surgery with posterior chamber lens implantation is presented in this case report. At the follow-up examination after cataract surgery, slit-lamp evaluation showed stromal striae, but it was impossible to diagnose the DMD due to the corneal edema. ASOCT imaging of the cornea revealed a DMD, and the patient underwent intracameral air injection to the anterior chamber through the site which was identified as intact by ASOCT. Follow-up ASOCT imaging revealed the reattachment of the Descemet’s membrane and reduced corneal thickness. If DMD is suspected in any cases, ASOCT can be useful to document and follow the postsurgical detachment of DMD and also to determine the site, configuration, and extent of the DMD, thus guiding the treatment method and monitoring the treatment outcome. (Turk J Ophthalmol 2014; 44: 407-9

  16. Evaluation of blotchy pigments in the anterior chamber angle as a sign of angle closure

    Directory of Open Access Journals (Sweden)

    Harsha L Rao

    2012-01-01

    Full Text Available Background: Blotchy pigments in the anterior chamber (AC angle are considered diagnostic of primary angle closure (PAC. But there are no reports either on the prevalence of blotchy pigments in AC angles or the validity of this sign. Aims: To determine the prevalence of blotchy pigments in AC angles and to evaluate their relationship with glaucomatous optic neuropathy (GON in eyes with occludable angles. Setting and Design: Cross-sectional, comparative study. Materials and Methods: Gonioscopy was performed in 1001 eyes of 526 subjects (245 eyes of 148 consecutive, occludable angle subjects and 756 eyes of 378 non-consecutive, open angle subjects, above 35 years of age. Quadrant-wise location of blotchy pigments was documented. Statistical Analysis: Odds of blotchy pigments in occludable angles against that in open angles were evaluated. Relationship of GON with blotchy pigments in occludable angle eyes was evaluated using a multivariate model. Results: Prevalence of blotchy pigments in occludable angles was 28.6% (95% CI, 22.9-34.3 and in open angles was 4.7% (95% CI, 3.2-6.3. Blotchy pigments were more frequently seen in inferior (16% and superior quadrants (15% of occludable angles, and inferior quadrant of open angles (4%. Odds of superior quadrant blotchy pigments in occludable angles were 33 times that in open angles. GON was seen in 107 occludable angle eyes. Blotchy pigments were not significantly associated with GON (odds ratio = 0.5; P = 0.1. Conclusions: Blotchy pigments were seen in 28.6% of occludable angle eyes and 4.7% of open angles eyes. Presence of blotchy pigments in the superior quadrant is more common in occludable angles. Presence of GON in occludable angle eyes was not associated with blotchy pigments.

  17. Evaluation of the anterior chamber angle in Asian Indian eyes by ultrasound biomicroscopy and gonioscopy

    Directory of Open Access Journals (Sweden)

    Kaushik Sushmita

    2006-01-01

    Full Text Available Purpose: To compare the ultrasound biomicroscopic measurement of the anterior chamber angle in Asian Indian eyes, with the angle width estimated by gonioscopy. Materials and Methods: Participants: Patients with open and closed angles attending a glaucoma clinic were recruited for the study. Observation Procedures: Temporal quadrants of the angles of patients were categorized by gonioscopy as Grade 0 to Grade 4, using Shaffer′s classification. These angles were quantified by ultrasound biomicroscopy (UBM using the following biometric characteristics: Angle opening distance at 250 µ (AOD 250 and 500 µ (AOD 500 from the scleral spur and trabecular meshwork-ciliary process distance (TCPD. The angles were further segregated as "narrow angles" (Schaffer′s Grade 2 or less and "open angles" (Schaffer′s Grade 3 and 4. Main Outcome Measures: The UBM measurements were computed in each case and analyzed in relation to the gonioscopic angle evaluation. Results: One hundred and sixty three eyes of 163 patients were analyzed. One hundred and six eyes had "narrow angles" and 57 eyes had "open angles" on gonioscopy. There was a significant difference among the mean UBM measurements of each angle grade estimated by gonioscopy ( P < 0.001. The Pearson correlation coefficient between all UBM parameters and gonioscopy grades was significant at the 0.01 level. The mean AOD 250, AOD 500 and TCPD in narrow angles were 58±49 µ, 102±84 µ and 653±124 respectively, while it was 176±47 µ, 291±62 µ and 883±94 µ in eyes with open angles ( P < 0.001 respectively. Conclusions: The angle width estimated by gonioscopy correlated significantly with the angle dimensions measured by UBM. Gonioscopy, though a subjective test, is a reliable method for estimation of the angle width.

  18. Evaluation of blotchy pigments in the anterior chamber angle as a sign of angle closure

    Science.gov (United States)

    Rao, Harsha L; Mungale, Sachin C; Kumbar, Tukaram; Parikh, Rajul S; Garudadri, Chandra S

    2012-01-01

    Background: Blotchy pigments in the anterior chamber (AC) angle are considered diagnostic of primary angle closure (PAC). But there are no reports either on the prevalence of blotchy pigments in AC angles or the validity of this sign. Aims: To determine the prevalence of blotchy pigments in AC angles and to evaluate their relationship with glaucomatous optic neuropathy (GON) in eyes with occludable angles. Setting and Design: Cross-sectional, comparative study. Materials and Methods: Gonioscopy was performed in 1001 eyes of 526 subjects (245 eyes of 148 consecutive, occludable angle subjects and 756 eyes of 378 non-consecutive, open angle subjects), above 35 years of age. Quadrant-wise location of blotchy pigments was documented. Statistical Analysis: Odds of blotchy pigments in occludable angles against that in open angles were evaluated. Relationship of GON with blotchy pigments in occludable angle eyes was evaluated using a multivariate model. Results: Prevalence of blotchy pigments in occludable angles was 28.6% (95% CI, 22.9-34.3) and in open angles was 4.7% (95% CI, 3.2-6.3). Blotchy pigments were more frequently seen in inferior (16%) and superior quadrants (15%) of occludable angles, and inferior quadrant of open angles (4%). Odds of superior quadrant blotchy pigments in occludable angles were 33 times that in open angles. GON was seen in 107 occludable angle eyes. Blotchy pigments were not significantly associated with GON (odds ratio = 0.5; P = 0.1). Conclusions: Blotchy pigments were seen in 28.6% of occludable angle eyes and 4.7% of open angles eyes. Presence of blotchy pigments in the superior quadrant is more common in occludable angles. Presence of GON in occludable angle eyes was not associated with blotchy pigments. PMID:23202393

  19. Nongranulomatous anterior uveitis in a patient with Usher syndrome

    OpenAIRE

    Alzuhairy, Sultan Abdulaziz S.; Alfawaz, Abdullah

    2013-01-01

    A 34-year-old female with Usher syndrome, but no family history of similar illness, presented with complaints of vision reduction, redness, and photophobia. Biomicroscopic examination showed mildly injected conjunctivae bilateral, small, round keratic precipitates; bilateral +2 cells with no flare reaction in the anterior chamber; and bilateral posterior subcapsular cataracts. No associated posterior synechiae, angle neovascularization, or iris changes were detected; normal intraocular pressu...

  20. Capsular phimosis with complete occlusion of the anterior capsular opening after intact continuous curvilinear capsulorrhexis

    International Nuclear Information System (INIS)

    Al-Kharashi, Soliman A.; Al-Obailan, Majed

    2009-01-01

    Shrinkage and whitening of the anterior capsule opening - capsular contraction syndrome - is a well-known complication after continuous curvilinear capsulorrhexis. A 72-year-old women underwent continuous curvilinear capsulorrhexis, phacoemulsification, and implantation of posterior chamber intraocular lens with polymethylmethacrylate haptics. Four months postoperatively, the patient reported deterioration in visual acuity that was resulted due to complete occlusion of anterior capsular opening by fibrotic tissue. The fibrous membrane was excised surgically in capsulorrhexis fashion. (author)

  1. Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography.

    Science.gov (United States)

    Chansangpetch, Sunee; Nguyen, Anwell; Mora, Marta; Badr, Mai; He, Mingguang; Porco, Travis C; Lin, Shan C

    2018-03-01

    To assess the interdevice agreement between swept-source Fourier-domain and time-domain anterior segment optical coherence tomography (AS-OCT). Fifty-three eyes from 41 subjects underwent CASIA2 and Visante OCT imaging. One hundred eighty-degree axis images were measured with the built-in two-dimensional analysis software for the swept-source Fourier-domain AS-OCT (CASIA2) and a customized program for the time-domain AS-OCT (Visante OCT). In both devices, we examined the angle opening distance (AOD), trabecular iris space area (TISA), angle recess area (ARA), anterior chamber depth (ACD), anterior chamber width (ACW), and lens vault (LV). Bland-Altman plots and intraclass correlation (ICC) were performed. Orthogonal linear regression assessed any proportional bias. ICC showed strong correlation for LV (0.925) and ACD (0.992) and moderate agreement for ACW (0.801). ICC suggested good agreement for all angle parameters (0.771-0.878) except temporal AOD500 (0.743) and ARA750 (nasal 0.481; temporal 0.481). There was a proportional bias in nasal ARA750 (slope 2.44, 95% confidence interval [CI]: 1.95-3.18), temporal ARA750 (slope 2.57, 95% CI: 2.04-3.40), and nasal TISA500 (slope 1.30, 95% CI: 1.12-1.54). Bland-Altman plots demonstrated in all measured parameters a minimal mean difference between the two devices (-0.089 to 0.063); however, evidence of constant bias was found in nasal AOD250, nasal AOD500, nasal AOD750, nasal ARA750, temporal AOD500, temporal AOD750, temporal ARA750, and ACD. Among the parameters with constant biases, CASIA2 tends to give the larger numbers. Both devices had generally good agreement. However, there were proportional and constant biases in most angle parameters. Thus, it is not recommended that values be used interchangeably.

  2. Penetration of 45Ca in rabbit cornea following the introduction of air in the anterior chamber and its paracenthesis and following experimental intraocular hypertension

    International Nuclear Information System (INIS)

    Votockova, J.; Obenberger, J.; Babicky, A.

    1977-01-01

    In one group of Chinchilla rabbits the aqueous humor was withdrawn and the anterior chamber was refilled with air; in a second group only simple paracenthesis and withdrawal were performed; in a third group of animals experimental intraocular hypertension was produced by means of a subconjunctival injection of hypertonic sodium chloride. Immediately after these operations, a solution of 45 CaCl 2 was intravenously injected, and the rabbits were sacrificed after an interval of 30 min or 120 min. The corneas were excised and the radioactivity in central parts (trephined discs of 8 mm in diameter) and in remaining peripheral parts was determined. In all groups the corneal radioactivity in operated eyes exceeded the values found in the contralateral corneas of not operated eyes, radioactivity in these eyes being equal to the radioactivity found in the corneas of not operated rabbits in the control group. Various possible explanations of the increase of corneal radioactivity in operated eyes are briefly discussed. (author)

  3. Analysis of incidence and related factors on effusion of anterior chamber after phacoemulsification combined with intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Bing-Bing Zhao

    2018-02-01

    Full Text Available AIM: To investigate the incidence and related factors on effusion of anterior chamber(ACafter phacoemulsification(PEcombined with intraocular lens(IOLimplantation. METHODS: Totally 359 cases of cataract(375 eyesunderwent PE combined with IOL implantation were collected in our hospital. The incidence of AC exudation after operation and related factors were analyzed by single factor and multiple logistic regression analysis. RESULTS: The group was included in 359 cases(375 eyes. The incidence of postoperative AC exudation in the study group was 5.9%(22/375. The preoperative intraocular pressure(IOP, visual acuity before and after surgery, nuclear grades, posterior capsular rupture(PCRrate and ultrasonic accumulated energy complex parameter(AECPof the study group showed statistically significant difference compared with the control group(all P21mmHg, intraoperative pupil diameter 7.25(%×min, the lens nucleus grade ≥ IV were risk factors of AC exudation after PE combined with IOL implantation in patients with cataract(all P21mmHg, ultrasound AECP >7.25 were independent risk factors of AC exudation after PE combined with IOL implantation in patients with cataract(all PCONCLUSION: High myopia, glaucoma, uveitis, the lens nucleus grade ≥ IV, the incidence of intraoperative PCR, preoperative IOP>21mmHg, ultrasonic AECP>7.25 are independent risk factors of AC exudation after PE combined with IOL implantation in patients with cataract, with such risk factors in patients with cataract should be paid closely attention and timely diagnosis and treatment in clinic.

  4. Diurnal Alterations of Refraction, Anterior Segment Biometrics, and Intraocular Pressure in Long-Time Dehydration due to Religious Fasting.

    Science.gov (United States)

    Baser, Gonen; Cengiz, Hakan; Uyar, Murat; Seker Un, Emine

    2016-01-01

    To investigate the effects of dehydration due to fasting on diurnal changes of intraocular pressure, anterior segment biometrics, and refraction. The intraocular pressures, anterior segment biometrics (axial length: AL; Central corneal thickness: CCT; Lens thickness: LT; Anterior chamber depth: ACD), and refractive measurements of 30 eyes of 15 fasting healthy male volunteers were recorded at 8:00 in the morning and 17:00 in the evening in the Ramadan of 2013 and two months later. The results were compared and the statistical analyses were performed using the Rstudio software version 0.98.501. The variables were investigated using visual (histograms, probability plots) and analytical methods (Kolmogorov-Smirnov/Shapiro-Wilk test) to determine whether or not they were normally distributed. The refractive values remained stable in the fasting as well as in the control period (p = 0.384). The axial length measured slightly shorter in the fasting period (p = 0.001). The corneal thickness presented a diurnal variation, in which the cornea measured thinner in the evening. The difference between the fasting and control period was not statistically significant (p = 0.359). The major differences were observed in the anterior chamber depth and IOP. The ACD was shallower in the evening during the fasting period, where it was deeper in the control period. The diurnal IOP difference was greater in the fasting period than the control period. Both were statistically significant (p = 0.001). The LT remained unchanged in both periods. The major difference was shown in the anterior chamber shallowing in the evening hours and IOP. Our study contributes the hypothesis that the posterior segment of the eye is more responsible for the axial length alterations and normovolemia has a more dominant influence on diurnal IOP changes.

  5. Application of ultrasound biomicro-scopy in the planning of cataract surgery in anterior megalophthalmos

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Zare

    2011-01-01

    Full Text Available Anterior megalophthalmos, a rare hereditary disorder, is macrocornea (horizontal corneal diameter more than 13 mm in association with enlarged lens-iris diaphragm and ciliary ring. One of the major challenging issues in the cataract surgery of these patients is preventing intraocular lens (IOL malposition, because of probable large capsular bag. Several approaches have been selected by previous surgeons, such as, custom-made anterior chamber IOLs. In this study, we show a normal capsular bag diameter despite ciliary ring enlargement, with application of ultrasound biomicroscopy (UMB. We suggest that in cases of anterior megalophthalmos without phacodonesis, UBM could measure the actual size of the capsular bag and obviate the need for further procedures.

  6. The effect of pharmacologic pupillary dilatation on anterior segment parameters in patients with exfoliation syndrome

    Directory of Open Access Journals (Sweden)

    Mehmet Cem Mocan

    2014-01-01

    Conclusion: Pupillary dilatation with a single drop of 1.0% cyclopentolate, 2.5% phenylephrine or 1% tropicamide is not associated with shallowing of the anterior chamber or narrowing of the ACA in patients with XFS who present with open angles.

  7. Sexual dimorphism of the internal mandibular chamber in Fayum Pliohyracidae (Mammalia)

    Science.gov (United States)

    de Blieux, D.D.; Baumrind, M.R.; Simons, E.L.; Chatrath, P.S.; Meyer, G.E.; Attia, Y.S.

    2006-01-01

    An internal mandibular fenestra and chamber are found in many fossil hyracoids. The internal mandibular fenestra is located on the lingual surface of the mandibular corpus and opens into a chamber within the mandible. The mandibular chamber is maximally developed in late Eocene Thyrohyrax meyeri and early Oligocene Thyrohyrax domorictus from the Fayum Province of Egypt. The function of this chamber is unknown as it is not found in extant hyraxes, nor is it known to occur in any other mammal. In Thyrohyrax, this feature appears to be sexually dimorphic because it is confined to roughly one half of the specimens that otherwise cannot be separated by dental characteristics or measurements. It has been suggested that the chamber is found in females based on the presumed distribution of this character in other fossil hyracoids. Fossils from Fayum Quarry L-41, preserving the sexually dimorphic anterior dentition, show that, in Thyrohyrax meyeri and Thyrohyrax domorictus, the internal mandibular chamber is found in males. In Thyrohyrax litholagus, an internal mandibular fenestra and inflated mandibular chamber occurs in males whereas females show the variable presence of an internal mandibular fossa or fenestra but lack an expanded chamber. Other genera show differing patterns of sexual variation in which some Fayum hyracoids have an internal mandibular fenestra in both sexes but with the greatest development of the mandibular chamber occurring in males. We review functions proposed for the internal mandibular chamber and suggest that it housed a laryngeal air sac that may have had a vocal function by acting as a resonating chamber. ?? 2006 by the Society of Vertebrate Paleontology.

  8. Evaluation and comparison of indentation ultrasound biomicroscopy gonioscopy in relative pupillary block, peripheral anterior synechia, and plateau iris configuration.

    Science.gov (United States)

    Matsunaga, Koichi; Ito, Kunio; Esaki, Koji; Sugimoto, Kota; Sano, Toru; Miura, Katsuya; Sasoh, Mikio; Uji, Yukitaka

    2004-12-01

    To evaluate and compare the findings and changes of the anterior chamber angle configuration with indentation ultrasound biomicroscopy (UBM) gonioscopy in relative pupillary block (RPB), peripheral anterior synechia (PAS), and plateau iris configuration (PIC). This study included 73 eyes of 52 patients with RPB (n = 26), PAS (n = 21), or PIC (n = 26). First, a conventional UBM scan was performed using a normal size standard eye cup before indentation. Then, for indentation UBM gonioscopy, scans were performed using a new eye cup that we designed. For evaluation of the angle, angle opening distance 500 and angle recess area were recorded and evaluated with regard to the effect of expansion on the anterior chamber angle. Indentation UBM gonioscopy showed the characteristic images in each of the eyes. The angle of all examined eyes was significantly widened with indentation (P gonioscopy is a very useful method for observing the angle and diagnosis of RPB, PAS, and PIC.

  9. Anterior segment changes after pharmacologic mydriasis using Pentacam and optical coherence tomography in angle closure suspects

    Directory of Open Access Journals (Sweden)

    Jing-Min Guo

    2015-10-01

    Full Text Available AIM:To compare the dynamic changes of anterior segment parameters especially iris morphology induced by pharmacologic mydriasis between angle closure suspects and normal controls.METHODS:The study group comprised 19 eyes of 19 angle closure suspects and 19 eyes of 19 age- and sex-matched normal open-angle eyes. Pentacam and optical coherence tomography measurements before and 30min after instillation of compound tropicamide eye drop were performed and compared. Biometric evaluations of iris tomography and anterior chamber angle were estimated by a customized image-processing software.RESULTS:Baseline axial length, iris cross sectional area and volume did not differ significantly between angle closure suspects and normal controls. Angle closure suspects had smaller pupil size, narrower anterior segment dimension and axial length, thinner iris with greater curve in comparison with normal controls. Pharmacologic mydriasis led to significant increments in iris thickness at 750 μm, anterior chamber depth and volume, whereas significant decrements in iris curve, cross sectional area and volume in both groups. Angle opening distance at 500 μm was increased significantly in normal controls (from 0.465±0.115 mm to 0.539±0.167 mm, P=0.009, but not in angle closure suspects (from 0.125±0.100 mm to 0.145±0.131 mm, P=0.326. Iris volume change per millimeter of pupil dilation (△IV/△PD decreased significantly less in angle closure suspects than normal controls (-2.47±1.33 mm2 vs -3.63±1.58 mm2, P=0.019. Linear regression analysis showed that the change of angle opening distance at 500 μm was associated most with the change of central anterior chamber depth (β=0.841, P=0.002 and △IV/△PD (β=0.028, P=0.002, followed by gender (β=0.062, P=0.032.CONCLUSION:Smaller iris volume decrement per millimeter of pupil dilation is related significantly with the less anterior angle opening in angle closure suspects after pharmacologic mydriasis. Dynamic

  10. Nongranulomatous anterior uveitis in a patient with Usher syndrome.

    Science.gov (United States)

    Alzuhairy, Sultan Abdulaziz S; Alfawaz, Abdullah

    2013-10-01

    A 34-year-old female with Usher syndrome, but no family history of similar illness, presented with complaints of vision reduction, redness, and photophobia. Biomicroscopic examination showed mildly injected conjunctivae bilateral, small, round keratic precipitates; bilateral +2 cells with no flare reaction in the anterior chamber; and bilateral posterior subcapsular cataracts. No associated posterior synechiae, angle neovascularization, or iris changes were detected; normal intraocular pressures were obtained. Fundus examination demonstrated waxy pallor of both optic nerves, marked vasoconstriction in retinal vessels, and retinal bone spicule pigment formation, with a normal macula. Electroretinography confirmed the diagnosis of retinitis pigmentosa, optical coherent tomography was normal and otolaryngology consultation was conducted. To our knowledge, an association between Usher syndrome and bilateral nongranulomatous anterior uveitis has not been previously reported, and our purpose is to report this association.

  11. Intracapsular lens extraction for the treatment of pupillary block glaucoma associated with anterior subluxation of the crystalline lens.

    Science.gov (United States)

    Kim, Yong Joon; Ha, Seung Joo

    2013-01-01

    To report a case of pupillary block glaucoma associated with spontaneous crystalline lens subluxation into the anterior chamber in a 34-year-old man. Dry vitrectomy was performed for securing enough retrolental space, and an intracapsular lens extraction was then performed via a corneolimbal incision. Additional endothelial cell damage was avoided with an injection of viscoelastics and gentle extraction of the crystalline lens. After deepening of the anterior chamber, scleral fixation of the intraocular lens was performed with an ab externo technique. Two months after the operation, a well-fixated intraocular lens was observed and intraocular pressure was stable. The postoperative corneal astigmatism was -3.5 dpt, and the patient had a best-corrected visual acuity of 20/25. Postoperative complications included decreased endothelial cell count and sector iris paralysis near the incision site. An anteriorly subluxated crystalline lens can cause pupillary block glaucoma in healthy young adults. To prevent intraoperative complications, intracapsular lens extraction with dry vitrectomy can be a good surgical option. The endothelial cell density should be closely monitored after surgery.

  12. Two-chambered right ventricle resulting from aberrant muscle bundles: a case report

    International Nuclear Information System (INIS)

    Lim, T. H.; Ko, K. H.; Im, C. K.; Han, M. C.; Chi, J. G

    1979-01-01

    The 'Two-chambered right ventricle' is a rare, but unique congenital cardiac anomaly characterized by subdivision of the right ventricle into proximal high pressure chamber and distal low pressure chamber by hypertrophied aberrant muscle bundles. The aberrant muscle bundles traverse the right ventricle from the region of crista supraventricular is to the lower part of the anterior wall of the right ventricle. The ' Two-chambered right ventricle' is usually associated with other congenital cardiac anomalies such as ventricular septal defect, pulmonary valvular stenosis, etc. Therefore this anomaly could be mistakenly diagnosed as Tetralogy of Fallot or isolated interventricular septal defect. The need to separate this entity from other types of infundibular stenosis is emphasized because of the important surgical implications. Authors recently experienced a case of the T wo-chambered right ventricle' resulting from aberrant muscle bundles, that are associated with other cardiac anomalies i.e., pulmonary valvular stenosis, aysplastic tricuspid valve with regurgitation and partial anomalous pulmonary venous return to the right atrium. Here we present the findings of E.K.G., cardiac catheterization, simple chest pa, cine-right ventriculography, and autopsy together with a review of related articles.

  13. Two-chambered right ventricle resulting from aberrant muscle bundles: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Lim, T. H.; Ko, K. H.; Im, C. K.; Han, M. C.; Chi, J. G [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1979-12-15

    The 'Two-chambered right ventricle' is a rare, but unique congenital cardiac anomaly characterized by subdivision of the right ventricle into proximal high pressure chamber and distal low pressure chamber by hypertrophied aberrant muscle bundles. The aberrant muscle bundles traverse the right ventricle from the region of crista supraventricular is to the lower part of the anterior wall of the right ventricle. The ' Two-chambered right ventricle' is usually associated with other congenital cardiac anomalies such as ventricular septal defect, pulmonary valvular stenosis, etc. Therefore this anomaly could be mistakenly diagnosed as Tetralogy of Fallot or isolated interventricular septal defect. The need to separate this entity from other types of infundibular stenosis is emphasized because of the important surgical implications. Authors recently experienced a case of the {sup T}wo-chambered right ventricle' resulting from aberrant muscle bundles, that are associated with other cardiac anomalies i.e., pulmonary valvular stenosis, aysplastic tricuspid valve with regurgitation and partial anomalous pulmonary venous return to the right atrium. Here we present the findings of E.K.G., cardiac catheterization, simple chest pa, cine-right ventriculography, and autopsy together with a review of related articles.

  14. Intravitreal Bevacizumab injection combined duplex technique in treatment of neovascular glaucoma

    Directory of Open Access Journals (Sweden)

    Zheng-Jun Hu

    2015-05-01

    Full Text Available AIM: To observe the clinical curative effect of intravitreal Bevacizumab injection combined duplex technique in treatment of neovascular glaucoma(NVG.METHODS:Totally 25 eyes of 25 patients with NVG who underwent intravitreal Bevacizumab injection of 1.0mg(0.05mL, after the regression of iris neovascularization, 5 eyes with anterior chamber paracentesis fluid auxiliary controlled intraocular pressure. After 2wk, patients were treated by trabeculectomy and phacomulsification(9 eyes were implanted intraocular lens. The changes and complications of intraocular pressure, visual acuity, corneas and neovessels were observed after surgery, and followed up 12mo.RESULTS:After injection Bevacizumab in 25 eyes, iris neovascularization of 20 eyes subsided in 3~5d, and 5 eyes subsided in 7d. After controlling intraocular pressure, count of the corneal endothelial cell were 1 629±226mm2, and none suffered decompensation of corneal endothelium after two-surgery of trabeculectomy and phacomulsification. After followed up 12mo, intraocular pressure of 20 eyes were controlled in normal range; 2 eyes could control in normal range after treated by a kind of anti-glaucoma medicine and 3 eyes was 34~38mmHg after treated by anti-glaucoma medicine. 9 eyes had improved vision after implanted intraocular lens.CONCLUSION:Intravitreal Bevacizumab injection can subside iris and anterior chamber angle neovascularization effectively in a short time and reduce intraocular pressure. It can also reduce the risk of bleeding during operation or after operation. Intravitreal Bevacizumab injection combined with two-surgery of trabeculectomy and phacomulsification can treat neovascular glaucoma effectively.

  15. Changes in anterior segment morphology in response to illumination and after laser iridotomy in Asian eyes: an anterior segment OCT study

    Science.gov (United States)

    See, Jovina L S; Chew, Paul T K; Smith, Scott D; Nolan, Winifred P; Chan, Yiong‐Huak; Huang, David; Zheng, Ce; Foster, Paul J; Aung, Tin; Friedman, David S

    2007-01-01

    Aim Using the anterior segment optical coherence tomography (AS‐OCT) to quantify changes in anterior segment morphology going from light to dark and following laser iridotomy (LI). Methods Prospective observational study. 17 consecutive subjects without peripheral anterior synechiae undergoing LI were evaluated using gonioscopy and AS‐OCT. Angle configuration including angle opening distance (AOD) at 500 microns anterior to the scleral spur, AOD500, trabecular‐iris space area up to 750 microns from the scleral spur, TISA750 and the increase in angle opening going from dark to light conditions was determined. Results Both mean AOD500 and TISA750 increased nearly threefold going from dark to light. Both also significantly increased following LI (p<0.001) as did gonioscopic grading of the angle in all quadrants (p<0.001, McNemar's test). Angles were more than twice as wide on average in the dark after LI than before LI (p<0.05). Both the mean absolute change and the mean proportionate change in AOD500 and TISA750 when going from light to dark were greater after LI than before (p<0.05). Conclusion Increased illumination as well as LI resulted in significant widening of the anterior chamber angle. AS‐OCT (which does not require a water bath and can be performed with the patient at the slit lamp) identified similar magnitude changes as those previously reported using ultrasound biomicroscopy (UBM). Furthermore, the angle appears to open more both in absolute terms and and proportionate terms in response to illumination after LI. PMID:17504852

  16. The use of low dose methotrexate in children with chronic anterior and intermediate uveitis.

    Science.gov (United States)

    Malik, A R; Pavesio, C

    2005-07-01

    To assess the efficacy of low dose methotrexate (MTX) therapy for children with chronic anterior and intermediate uveitis. A retrospective case review of 10 children who received MTX for chronic uveitis at a tertiary referral centre was performed. The following data were recorded for each patient: age, sex, race, duration of uveitis, primary diagnosis, anatomical localisation of uveitis, corticosteroid therapy, dose range of MTX, duration of MTX therapy, and side effects of MTX therapy. Several clinical parameters were evaluated to study the effect of MTX. These included visual acuity, anterior chamber inflammation, and topical and oral corticosteroid requirement. After MTX VA of 6/6 or better was present in 100% right eyes and 80% left eyes (p = 0.055 and p = 0.016, respectively). Anterior chamber inflammation decreased in 60% of children after MTX (p = 0.0168). The requirement of topical steroid decreased from a mean of 5.6 times a day before MTX to 1.5 times a day after MTX (p = 0.005). The dose of oral steroid decreased from a mean of 18 mg per day to 2.85 mg per day (p = 0.012). The most common adverse effect was nausea (20%). No patient required discontinuation of MTX because of side effects. MTX is effective and safe for chronic anterior and intermediate uveitis in children. An increase awareness of its efficacy is required among paediatricians and ophthalmologists to prevent sight threatening complication of chronic uveitis and its treatment with long term use of steroids.

  17. Clinical outcomes of pars plicata anterior vitrectomy: 2-year results

    Directory of Open Access Journals (Sweden)

    Priya Narang

    2015-01-01

    Full Text Available Purpose: To demonstrate the safety and outcome of a surgical approach that uses pars plicata site for anterior vitrectomy during phacoemulsification procedure complicated by posterior capsule rupture and residual cortical matter. Design: Single center, retrospective, interventional, noncomparative study. Materials and Methods: Medical records of a consecutive series of 35 eyes of 35 patients who underwent pars plicata anterior vitrectomy (PPAV were reviewed. The main outcome measures were corrected and uncorrected distance visual acuity (CDVA, UDVA, early and late postoperative complications and intraocular pressure (IOP. Ultrasound biomicroscopic (UBM evaluation of sclerotomy site and spectral domain optical coherence tomography analysis for central macular thickness (CMT was performed. The final visual outcome at 2 years was evaluated. Results: At 2 years follow-up, the mean postoperative UDVA (logarithm of the minimum angle of resolution [logMAR] and CDVA (logMAR was 0.49 ± 0.26 and 0.19 ± 0.14, respectively. There was no significant change in the IOP (P = 0.061 and the mean CMT at 2 years was 192.5 ± 5.54 mm. The postoperative UBM image of the sclerotomy site at 8 weeks demonstrated a clear wound without any vitreous adhesion or incarceration. Intraoperative hyphema was seen in 1 (2.8% case and postoperative uveitis was seen in 2 (5.7% cases, which resolved with medications. No case of an iatrogenic retinal break or retinal detachment was reported. Conclusions: PPAV enables a closed chamber approach, allows thorough cleanup of vitreous in the pupillary plane and anterior chamber and affords better access to the subincisional and retropupillary cortical remnant with a significant visual outcome and an acceptable complication rate.

  18. Intraocular Foreign Body Detected by Gonioscopy in the Anterior Chamber Angle

    Directory of Open Access Journals (Sweden)

    Özdemir Özdemir

    2013-08-01

    Full Text Available 45-year-old male patient was referred to our hospital with suspicion of foreign body in the right eye. It was learned that a metal burr entered his right eye 2 days ago. Best-corrected visual acuity in the right eye was 9/10. Biomicroscopic examination showed a 2-mm fullthickness corneal incision in the lower paracentral cornea. Defect on the iris corresponding to the incision line drew our attention. Seidel test was negative. After dilatation, the anterior lens capsule and fundus examinations were performed and were normal. The presence of intraocular foreign body (IOFB was suspected and it was detected in the lower quadrant of the iridocorneal angle by gonioscopy. Emergency surgery was performed and IOFB was extracted. (Turk J Ophthalmol 2013; 43: 278-81

  19. Toxic anterior-segment syndrome (TASS

    Directory of Open Access Journals (Sweden)

    Cetinkaya S

    2014-10-01

    Full Text Available Servet Cetinkaya,1 Zeynep Dadaci,2 Hüsamettin Aksoy,3 Nursen Oncel Acir,2 Halil Ibrahim Yener,4 Ekrem Kadioglu5 1Ophthalmology Clinics, Turkish Red Crescent Hospital, Konya, 2Department of Ophthalmology, Faculty of Medicine, Mevlana University, Konya, 3Ophthalmology Clinics, Karaman State Hospital, Karaman, 4Konya Eye Center Hospital, Konya, 5Ophthalmology Clinics, Beyhekim State Hospital, Konya, Turkey Purpose: To evaluate the clinical findings and courses of five patients who developed toxic anterior-segment syndrome (TASS after cataract surgery and investigate the cause.Materials and methods: In May 2010, on the same day, ten patients were operated on by the same surgeon. Five of these patients developed TASS postoperatively.Results: Patients had blurred-vision complaints on the first day after the operation, but no pain. They had different degrees of diffuse corneal edema, anterior-chamber reaction, fibrin, hypopyon, iris atrophies, and dilated pupils. Their vision decreased significantly, and their intraocular pressures increased. Both anti-inflammatory and antiglaucomatous therapies were commenced. Corneal edema and inflammation resolved in three cases; however, penetrating keratoplasty was needed for two cases and additional trabeculectomy was needed for one case. Although full investigations were undertaken at all steps, we could not find the causative agent.Conclusion: TASS is a preventable complication of anterior-segment surgery. Recognition of TASS, differentiating it from endophthalmitis, and starting treatment immediately is important. Controlling all steps in surgery, cleaning and sterilization of the instruments, and training nurses and other operation teams will help us in the prevention of TASS. Keywords: cataract, phacoemulsification, TASS, corneal edema, inflammation

  20. The Relationship between Anterior Chamber Depth, Axial Length and Intraocular Lens Power among Candidates for Cataract Surgery.

    Science.gov (United States)

    Sedaghat, Mohammad Reza; Azimi, Ali; Arasteh, Peyman; Tehranian, Naghmeh; Bamdad, Shahram

    2016-10-01

    Basic anatomical parameters in ophthalmology are variable in different countries according to ethnic groups, genetics and some environmental factors. The aim of this study was to determine the relationship between axial length (AL), anterior chamber depth (ACD) and intraocular lens power (IOL) in a referral center from eastern Iran among patients who had cataract surgery, in comparison to studies from other regions of the world. In a cross-sectional retrospective study from 2011 to 2013, the records of 698 cataract patients referring to Khatam Al Anbia general hospital in Mashhad, Iran were evaluated. We divided patients, based on their AL and ACD, into three separate groups and compared their results. The SPSS software was used for data analysis. The Chi-Square test and the Independent-samples t-test were used to compare qualitative and quantitative data between two groups, respectively. The Kendall and the Pearson product-moment correlation tests were used to assess the relationship between AL and ACD. The linear Regression model was used to obtain a mathematical model to estimate ACD, using AL, age and sex. Among individuals who had normal AL (between 22-24.5mm), there was a positive correlation between AL and ACD (p24.5mm), no significant correlation was detected. We also found that older people have shorter AL (p=0.001 and r=-0.287). Men have an average longer AL (23.7±2.4mm vs. 22.9±2.1mm; pworld and although some anatomical variations may exist regarding ophthalmic anatomy, factors like race and geographical area have little effect on the relationship between ACD, AL and IOL power calculation, furthermore our results support the use of third and fourth generation formulas for IOL power calculation.

  1. Albumin infusion in patients undergoing large-volume paracentesis: a meta-analysis of randomized trials.

    Science.gov (United States)

    Bernardi, Mauro; Caraceni, Paolo; Navickis, Roberta J; Wilkes, Mahlon M

    2012-04-01

    Albumin infusion reduces the incidence of postparacentesis circulatory dysfunction among patients with cirrhosis and tense ascites, as compared with no treatment. Treatment alternatives to albumin, such as artificial colloids and vasoconstrictors, have been widely investigated. The aim of this meta-analysis was to determine whether morbidity and mortality differ between patients receiving albumin versus alternative treatments. The meta-analysis included randomized trials evaluating albumin infusion in patients with tense ascites. Primary endpoints were postparacentesis circulatory dysfunction, hyponatremia, and mortality. Eligible trials were sought by multiple methods, including computer searches of bibliographic and abstract databases and the Cochrane Library. Results were quantitatively combined under a fixed-effects model. Seventeen trials with 1,225 total patients were included. There was no evidence of heterogeneity or publication bias. Compared with alternative treatments, albumin reduced the incidence of postparacentesis circulatory dysfunction (odds ratio [OR], 0.39; 95% confidence interval [CI], 0.27-0.55). Significant reductions in that complication by albumin were also shown in subgroup analyses versus each of the other volume expanders tested (e.g., dextran, gelatin, hydroxyethyl starch, and hypertonic saline). The occurrence of hyponatremia was also decreased by albumin, compared with alternative treatments (OR, 0.58; 95% CI, 0.39-0.87). In addition, mortality was lower in patients receiving albumin than alternative treatments (OR, 0.64; 95% CI, 0.41-0.98). This meta-analysis provides evidence that albumin reduces morbidity and mortality among patients with tense ascites undergoing large-volume paracentesis, as compared with alternative treatments investigated thus far. Copyright © 2011 American Association for the Study of Liver Diseases.

  2. The effect of bevacizumab for anterior segment neovascularization after silicone oil removal in eyes with previous vitreoretinal surgery.

    Science.gov (United States)

    Batman, C; Ozdamar, Y

    2010-07-01

    To report the outcomes of the use of intracameral bevacizumab for iris neovascularization occurring after silicone oil (SO) removal in eyes undergoing vitreoretinal surgery (VRS). This study included 12 eyes that had iris neovascularization after SO removal. The clinical outcomes of 12 eyes after intravitreal bevacizumab injection were reviewed. There were eight men and four women with an average age of 41.58+/-12.68 years. All eyes had VRS for various vitreoretinal diseases. After the mean follow-up period of 9.7+/-5.3 months, SO removal was performed. Then, the patients were followed for more than 2 months and detailed retinal examinations and intraocular pressure (IOP) were normal during this period, but rubeosis iridis (RI) developed. RI was treated with 1 dose of 1.25 mg bevacizumab into the anterior chamber. After a mean follow-up period of 4.8+/-2.2 months, the regression of iris neovacularization was detected and IOP was below 21 mmHg in all eyes. Anterior segment neovascularization (ASNV) may develop through various mechanisms in patients with VRS after SO removal, and anterior chamber injection of bevacizumab may lead to regression of ASNV.

  3. BILATERAL SIMULTANEOUS ANTERIOR AND POSTERIOR LENTICONUS WITHOUT SYSTEMIC SIGNS

    Directory of Open Access Journals (Sweden)

    Hima Bindu

    2015-02-01

    Full Text Available A 21 year male came for eye checkup with a refractive error OD - 12.00 sph, - 2.25 @ 160° cyl and OS - 15.00 sph, - 2.50 @ 5°cyl and was referred to department of refractive surgery for opinion His BCVA in OD 6 / 18, OS 6/ 24. Slit lamp examination under dilation with phenylephrine plus tropic amide revealed the abnormal contour of the anterior and posterior lens capsule. Rest of the findings were normal with clear cornea, Von Herricks grade 3 deep anterior chamber, open angles in Gonioscopy. Retro illumination showed the typical’ oil droplet configuration’ in the lens. Retinal examination with the 90 D lens was otherwise normal except of the peculiar ‘OMEGA' shaped curving of the slit beam over the retina which occurred due the difference in the refractive power of the lens in the axial and paraxial zones of the lens

  4. Comparison of axial length, anterior chamber depth and intraocular lens power between IOLMaster and ultrasound in normal, long and short eyes.

    Science.gov (United States)

    Dong, Jing; Zhang, Yaqin; Zhang, Haining; Jia, Zhijie; Zhang, Suhua; Wang, Xiaogang

    2018-01-01

    To compare the axial length (AL), anterior chamber depth (ACD) and intraocular lens power (IOLP) of IOLMaster and Ultrasound in normal, long and short eyes. Seventy-four normal eyes (≥ 22 mm and ≤ 25 mm), 74 long eyes (> 25 mm) and 78 short eyes (devices in the order of IOLMaster followed by Ultrasound. The IOLP were calculated using a free online LADAS IOL formula calculator. The difference in AL and IOLP between IOLMaster and Ultrasound was statistically significant when all three groups were combined. The difference in ACD between IOLMaster and Ultrasound was statistically significant in the normal group (Peye group (Peye group (P = 0.465). For the IOLP difference between IOLMaster and Ultrasound in the normal group, the percentage of IOLP differences eye group, they were 90.5%, 5.4%, 4.1% and 0%, respectively. For the short eye group, they were 61.5%, 23.1%, 10.3%, and 5.1%, respectively. IOLMaster and Ultrasound have statistically significant differences in AL measurements and IOLP (using LADAS formula) for normal, long eye and short eye. The two instruments agree regarding ACD measurements for the long eye group, but differ for the normal and short eye groups. Moreover, the high percentage of IOLP differences greater than |0.5|D in the short eye group is noteworthy.

  5. A novel method for measuring anterior segment area of the eye on ultrasound biomicroscopic images using photoshop.

    Directory of Open Access Journals (Sweden)

    Zhonghao Wang

    Full Text Available To describe a novel method for quantitative measurement of area parameters in ocular anterior segment ultrasound biomicroscopy (UBM images using Photoshop software and to assess its intraobserver and interobserver reproducibility.Twenty healthy volunteers with wide angles and twenty patients with narrow or closed angles were consecutively recruited. UBM images were obtained and analyzed using Photoshop software by two physicians with different-level training on two occasions. Borders of anterior segment structures including cornea, iris, lens, and zonules in the UBM image were semi-automatically defined by the Magnetic Lasso Tool in the Photoshop software according to the pixel contrast and modified by the observers. Anterior chamber area (ACA, posterior chamber area (PCA, iris cross-section area (ICA and angle recess area (ARA were drawn and measured. The intraobserver and interobserver reproducibilities of the anterior segment area parameters and scleral spur location were assessed by limits of agreement, coefficient of variation (CV, and intraclass correlation coefficient (ICC.All of the parameters were successfully measured by Photoshop. The intraobserver and interobserver reproducibilities of ACA, PCA, and ICA were good, with no more than 5% CV and more than 0.95 ICC, while the CVs of ARA were within 20%. The intraobserver and interobserver reproducibilities for defining the spur location were more than 0.97 ICCs. Although the operating times for both observers were less than 3 minutes per image, there was significant difference in the measuring time between two observers with different levels of training (p<0.001.Measurements of ocular anterior segment areas on UBM images by Photoshop showed good intraobserver and interobserver reproducibilties. The methodology was easy to adopt and effective in measuring.

  6. Reproducibility of Scleral Spur Identification and Angle Measurements Using Fourier Domain Anterior Segment Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Ricardo J. Cumba

    2012-01-01

    Full Text Available Purpose. To evaluate intraobserver and interobserver agreement in locating the scleral spur landmark (SSL and anterior chamber angle measurements obtained using Fourier Domain Anterior Segment Optical Coherence Tomography (ASOCT images. Methods. Two independent, masked observers (SR and AZC identified SSLs on ASOCT images from 31 eyes with open and nonopen angles. A third independent reader, NPB, adjudicated SSL placement if identifications differed by more than 80 μm. Nine months later, SR reidentified SSLs. Intraobserver and interobserver agreement in SSL placement, trabecular-iris space area (TISA750, and angle opening distance (AOD750 were calculated. Results. In 84% of quadrants, SR’s SSL placements during 2 sessions were within 80 μm in both the X- and Y-axes, and in 77% of quadrants, SR and AZC were within 80 μm in both axes. In adjudicated images, 90% of all quadrants were within 80 μm, 88% in nonopen-angle eyes, and 92% in open-angle eyes. The intraobserver and interobserver correlation coefficients (with and without adjudication were above 0.9 for TISA750 and AOD750 for all quadrants. Conclusions. Reproducible identification of the SSL from images obtained with FD-ASOCT is possible. The ability to identify the SSL allows reproducible measurement of the anterior chamber angle using TISA750 and AOD750.

  7. A comparative study between clinical grading of anterior chamber flare and flare reading using the Kowa laser flare meter.

    Science.gov (United States)

    Konstantopoulou, Kallirroi; Del'Omo, Roberto; Morley, Anne M; Karagiannis, Dimitris; Bunce, Catey; Pavesio, Carlos

    2015-10-01

    To assess the accuracy of standard clinical grading of aqueous flare in uveitis according to the Standardization of Uveitis Nomenclature consensus, and compare the results with the readings of the laser flare meter, Kowa 500. Two examiners clinically graded the flare in 110 eyes. The flare was then measured using the Kowa laser flare meter. Twenty-nine eyes were graded as anterior chamber flare +2; for 18 of these, the clinicians were in agreement, the rest differed by the order of one grade. The range of the laser flare meter for these eyes was 5.2-899.1 photons/ms. The median value was 41.4. Seventy-four eyes were graded with flare +1. Agreement was established in 51 of these eyes. Disagreement for the rest was again by the order of 1, and the flare meter range was 1.1-169.9 photons/ms, median value 18.4. For the clinical measure of flare 0, the clinicians disagreed on three out of five eyes. The flare meter readings ranged from 2.5 to 14.1 photons/ms, median value 9.9. Only two eyes were graded with flare +3 and there was one step disagreement on both of them. We found little evidence of association between the flare readings and intraocular pressure or age. Our findings suggest that clinical evaluation of aqueous flare is subjective. Compared with the Kowa laser flare meter's numeric readings, the discrepancies observed indicate that clinical grading is an approximate science. The laser flare meter provides an accurate, reproducible, non-invasive assessment of aqueous flare that can prove valuable in research and clinical decisions.

  8. Implantação do mixoma infeccioso do coelho na câmara anterior do ôlho da cobaia

    Directory of Open Access Journals (Sweden)

    C. Magarinos Torres

    1948-09-01

    Full Text Available Mammalian cancer as well as the Rous chicken sarcoma has been successfully transplanted into the anterior chamber of the eyes of guinea pigs. It was of interest, therefore, to see if the infectious myxomatosis of rabbits, another representative of the infectious tumors, could be grown in the anterior chamber of the guinea pig eye, and, if growth occurred, to compare the tumor's behaviour with that of growths of the above mentioned etiology. Forty-three full-grown guinea pigs from mixed stocks were used throughout, and seventy-eight heterologous transplantation experiments were performed. The grafts measuring less than 2 mm. in diameter were cut from the subcutaneous tissue in skin lesions of rabbits with infectious myxomatosis recently killed. The transfer to the anterior chamber was performed after the usual technique. Some degree of partial survival was found in 23,8% of the grafts, in which typical myxoma cells could be demonstrated fifteen days after the transplantation. The transplant apparently does not increase in size, differing in that respect from that of the Rous chicken sarcoma, which increases in size by 2 or 3 diameters in 2 weeks (Shrigley, Greene & Duran-Reynals, 1945. The virus was still alive in 26% of the grafts 21 days after transplantation, and was able to induce a typical disease when injected to normal rabbits. No alteration in the properties of the virus after growth in the guinea pig was noticed, and this also is different from what happens with the Rous chicken sarcoma.

  9. Anterior but not posterior choroid changed before and during Valsalva manoeuvre in healthy Chinese: a UBM and SS-OCT study

    Science.gov (United States)

    Li, Fei; Gao, Kai; Li, Xingyi; Chen, Shida; Huang, Wenbin; Zhang, Xiulan

    2017-01-01

    Purpose To determine if the anterior choroid is involved in ocular change during the Valsalva manoeuvre (VM). Materials and methods Fifty-three healthy volunteers aged 18–65 years with normal visual field test results and no history of intraocular pressure (IOP) exceeding 21 mm Hg were recruited. Anterior and posterior choroidal changes before and during VM were recorded by ultrasound microscope and swept-source optical coherence tomography, respectively. Parameters of the anterior segment included ciliary body thickness (CBT0), thickness of the choroid at a distance of 4 mm from the root of the iris (CT4), anterior placement of the ciliary body (APCB) and trabecular–ciliary angle (TCA). Thickness of different layers of retina and posterior choroid were also measured and compared before and during VM. IOP, blood pressure (BP), heart rate (HR), axial length, spherical equivalent refractive error and pupil diameter (PD) were also recorded and analysed. Results VM caused elevated IOP, systolic BP, diastolic BP and increased HR. There was a significant increase in anterior parameters including CBT0, CT4 and APCB (p0.05). The mean change of CBT0, CT4 and APCB were: from 1.00±0.09 mm to 1.11±0.10 mm (p<0.001), from 0.29±0.04 mm to 0.36±0.05 mm (p<0.001), from 0.76±0.11 mm to 0.88±0.13 mm (p<0.001), respectively. However, there is no significant change in posterior choroid (from 215.74±60.23 µm to 214.82±61.32 µm, p=0.17). Conclusion We found that VM did not affect the posterior choroid, but it did cause thickening of the anterior choroid and the ciliary body, both of which led to a larger anterior placement of the ciliary body and a narrowed anterior chamber. The anterior (but not the posterior) choroid could be related to IOP elevation and a narrowed anterior chamber in primary angle closure diseases. PMID:28432110

  10. A novel method for measuring anterior segment area of the eye on ultrasound biomicroscopic images using photoshop.

    Science.gov (United States)

    Wang, Zhonghao; Liang, Xuanwei; Wu, Ziqiang; Lin, Jialiu; Huang, Jingjing

    2015-01-01

    To describe a novel method for quantitative measurement of area parameters in ocular anterior segment ultrasound biomicroscopy (UBM) images using Photoshop software and to assess its intraobserver and interobserver reproducibility. Twenty healthy volunteers with wide angles and twenty patients with narrow or closed angles were consecutively recruited. UBM images were obtained and analyzed using Photoshop software by two physicians with different-level training on two occasions. Borders of anterior segment structures including cornea, iris, lens, and zonules in the UBM image were semi-automatically defined by the Magnetic Lasso Tool in the Photoshop software according to the pixel contrast and modified by the observers. Anterior chamber area (ACA), posterior chamber area (PCA), iris cross-section area (ICA) and angle recess area (ARA) were drawn and measured. The intraobserver and interobserver reproducibilities of the anterior segment area parameters and scleral spur location were assessed by limits of agreement, coefficient of variation (CV), and intraclass correlation coefficient (ICC). All of the parameters were successfully measured by Photoshop. The intraobserver and interobserver reproducibilities of ACA, PCA, and ICA were good, with no more than 5% CV and more than 0.95 ICC, while the CVs of ARA were within 20%. The intraobserver and interobserver reproducibilities for defining the spur location were more than 0.97 ICCs. Although the operating times for both observers were less than 3 minutes per image, there was significant difference in the measuring time between two observers with different levels of training (pPhotoshop showed good intraobserver and interobserver reproducibilties. The methodology was easy to adopt and effective in measuring.

  11. Anterior segment optical coherence tomography for evaluation of cornea and ocular surface

    Directory of Open Access Journals (Sweden)

    Mittanamalli S Sridhar

    2018-01-01

    Full Text Available Current corneal assessment technologies make the process of corneal evaluation extremely fast and simple. Several devices and technologies allow to explore and manage patients better. Optical coherence tomography (OCT technology has evolved over the years, and hence a detailed evaluation of anterior segment (AS structures such as cornea, conjunctiva, tear meniscus, anterior chamber, iris, and crystalline lens has been possible in a noncontact and safe procedure. The purpose of this special issue is to present and update in the evaluation of cornea and ocular surface, and this paper reviews a description of the AS-OCT, presenting the technology and common clinical uses of OCT in the management of diseases involving cornea and ocular surface to provide an updated information of the clinical recommendations of this technique in eye care practice.

  12. Clinical utility of anterior segment swept-source optical coherence tomography in glaucoma

    Directory of Open Access Journals (Sweden)

    Dewang Angmo

    2016-01-01

    Full Text Available Optical coherence tomography (OCT, a noninvasive imaging modality that uses low-coherence light to obtain a high-resolution cross-section of biological structures, has evolved dramatically over the years. The Swept-source OCT (SS-OCT makes use of a single detector with a rapidly tunable laser as a light source. The Casia SS-1000 OCT is a Fourier-domain, SS-OCT designed specifically for imaging the anterior segment. This system achieves high resolution imaging of 10΅m (Axial and 30΅m (Transverse and high speed scanning of 30,000 A-scans per second. With a substantial improvement in scan speed, the anterior chamber angles can be imaged 360 degrees in 128 cross sections (each with 512 A-scans in about 2.4 seconds. We summarize the clinical applications of anterior segment SS-OCT in Glaucoma. Literature search: We searched PubMed and included Medline using the phrases anterior segment optical coherence tomography in ophthalmology, swept-source OCT, use of AS-OCT in glaucoma, use of swept-source AS-OCT in glaucoma, quantitative assessment of angle, filtering bleb in AS-OCT, comparison of AS-OCT with gonioscopy and comparison of AS-OCT with UBM. Search was made for articles dating 1990 to August 2015.

  13. Large-volume paracentesis with indwelling peritoneal catheter and albumin infusion: a community hospital study

    Directory of Open Access Journals (Sweden)

    Daniel K. Martin

    2016-10-01

    Full Text Available Background: The management of ascites can be problematic. This is especially true in patients with diuretic refractory ascites who develop a tense abdomen. This often results in hypotension and decreased venous return with resulting renal failure. In this paper, we further examine the risks and benefits of utilizing an indwelling peritoneal catheter to remove large-volume ascites over a 72-h period while maintaining intravascular volume and preventing renal failure. Methods: We retrospectively reviewed charts and identified 36 consecutive patients undergoing continuous large-volume paracentesis with an indwelling peritoneal catheter. At the time of drain placement, no patients had signs or laboratory parameters suggestive of spontaneous bacterial peritonitis. The patients underwent ascitic fluid removal through an indwelling peritoneal catheter and were supported with scheduled albumin throughout the duration. The catheter was used to remove up to 3 L every 8 h for a maximum of 72 h. Regular laboratory and ascitic fluid testing was performed. All patients had a clinical follow-up within 3 months after the drain placement. Results: An average of 16.5 L was removed over the 72-h time frame of indwelling peritoneal catheter maintenance. The albumin infusion utilized correlated to 12 mg/L removed. The average creatinine trend improved in a statistically significant manner from 1.37 on the day of admission to 1.21 on the day of drain removal. No patients developed renal failure during the hospital course. There were no documented episodes of neutrocytic ascites or bacterial peritonitis throughout the study review. Conclusion: Large-volume peritoneal drainage with an indwelling peritoneal catheter is safe and effective for patients with tense ascites. Concomitant albumin infusion allows for maintenance of renal function, and no increase in infectious complications was noted.

  14. A case of anterior ischemic optic neuropathy associated with uveitis

    Directory of Open Access Journals (Sweden)

    Sugahara M

    2013-05-01

    Full Text Available Michitaka Sugahara, Takayuki Fujimoto, Kyoko Shidara, Kenji Inoue, Masato Wakakura Inouye Eye Hospital, Tokyo, Japan Introduction: Here, we describe a patient who presented with anterior ischemic optic neuropathy (AION and subsequently developed uveitis. Case: A 69-year-old man was referred to our hospital and initially presented with best-corrected visual acuities (BCVA of 20/40 (right eye and 20/1000 (left eye and relative afferent pupillary defect. Slit-lamp examination revealed no signs of ocular inflammation in either eye. Fundus examination revealed left-eye swelling and a pale superior optic disc, and Goldmann perimetry revealed left-eye inferior hemianopia. The patient was diagnosed with nonarteritic AION in the left eye. One week later, the patient returned to the hospital because of vision loss. The BCVA of the left eye was so poor that the patient could only count fingers. Slit-lamp examination revealed 1+ cells in the anterior chamber and the anterior vitreous in both eyes. Funduscopic examination revealed vasculitis and exudates in both eyes. The patient was diagnosed with bilateral panuveitis, and treatment with topical betamethasone was started. No other physical findings resulting from other autoimmune or infectious diseases were found. No additional treatments were administered, and optic disc edema in the left eye improved, and the retinal exudates disappeared in 3 months. The patient's BCVA improved after cataract surgery was performed. Conclusion: Panuveitis most likely manifests after the development of AION. Keywords: anterior ischemic optic neuropathy, uveitis

  15. Anterior capsular staining with trypan blue for capsulorhexis in mature and hypermature cataracts. A preliminary study

    Directory of Open Access Journals (Sweden)

    Kothari Kulin

    2001-01-01

    Full Text Available Purpose: To study the efficacy and safety of 0.1% Trypan Blue dye to stain the anterior capsule for capsulorhexis in mature and hypermature cataracts. Methods: This preliminary study included 25 eyes of 25 patients with a unilateral mature or hypermature cataract, including one case of traumatic mature cataract. In all these cases 0.2ml of 0.1% trypan blue dye was used to stain the anterior capsule. The efficacy and safety of the dye was evaluated on the basis of intraoperative and postoperative observations. Results: In all 25 eyes the capsulorhexis was completed. There was peripheral extension of the capsulorhexis in the eye with traumatic cataract and the stained edge of the anterior capsule helped identification and redirection of the capsulorhexis. Successful phacoemulsification with intraocular lens implantation was performed in all eyes. Adverse reactions related to the dye such as raised intraocular pressure, anterior chamber inflammation and endothelial damage were not observed in the immediate postoperative period or at the end of mean follow-up of 3 months. Conclusion: Trypan blue dye staining of the anterior capsule appears to be a very useful and safe technique that simplifies capsulorhexis in mature and hypermature cataracts.

  16. Clinical profile of uveitis in Hansen’s disease after completion of treatment – A study of 50 cases using Polymerase Chain Reaction (PCR on aqueous humour

    Directory of Open Access Journals (Sweden)

    Radha Annamalai

    2016-05-01

    Full Text Available Chronic low grade anterior uveitis is the commonest cause of blindness in leprosy. It is usually asymptomatic until the late stages and patients seek help only after irreversible visual loss. We analysed patients who had a recurrence of uveitis after completion of treatment with anti-leprosy drugs and had been proven as histopathologically negative. The presence of chronic uveitis, complications and the extent of ocular damage it may cause, can continue even after treatment, emphasising the importance of follow-up, early detection and treatment. This is a prospective cohort study. Ophthalmic evaluation was performed using slit lamp examination, biomicroscopy, indirect ophthalmoscopy, applanation tonometry, corneal sensation and Schirmer’s test. Split skin microscopy was done to confirm the activity of leprosy. In patients with recalcitrant iridocyclitis, anterior chamber paracentesis was performed. The sample was analysed both by smear and polymerase chain reaction. The sequences that were targeted using PCR included genes encoding the DNA of 36-kDa antigen, 18-kDa antigen, 65-kDa antigen and the repetitive sequences among other M. leprae genes. Aqueous aspirate showed copies of mycobacterium leprae DNA in five out of twelve patients with recalcitrant anterior uveitis. Direct smear and staining with Ziehl- Neelson staining for mycobacteria was positive showing both live and dead bacilli. Live bacilli can persist in the aqueous humour even after completion of treatment. In our study this was more frequently observed in tuberculoid leprosy. This is possibly due to an immune mediated response combined with inadequate treatment dose in these patients.

  17. Effects of primary selective laser trabeculoplasty on anterior segment parameters

    Science.gov (United States)

    Guven Yilmaz, Suzan; Palamar, Melis; Yusifov, Emil; Ates, Halil; Egrilmez, Sait; Yagci, Ayse

    2015-01-01

    AIM To investigate the effects of selective laser trabeculoplasty (SLT) on the main numerical parameters of anterior segment with Pentacam rotating Scheimpflug camera in patients with ocular hypertension (OHT) and primary open angle glaucoma (POAG). METHODS Pentacam measurements of 45 eyes of 25 (15 females and 10 males) patients (12 with OHT, 13 with POAG) before and after SLT were obtained. Measurements were taken before and 1 and 3mo after SLT. Pentacam parameters were compared between OHT and POAG patients, and age groups (60y and older, and younger than 60y). RESULTS The mean age of the patients was 57.8±13.9 (range 20-77y). Twelve patients (48%) were younger than 60y, while 13 patients (52%) were 60y and older. Measurements of pre-SLT and post-SLT 1mo were significantly different for the parameters of central corneal thickness (CCT) and anterior chamber volume (ACV) (P0.05). CONCLUSION SLT leads to significant increase in CCT and decrease in ACV at the 1st month of the procedure. Effects of SLT on these anterior segment parameters, especially for CCT that interferes IOP measurement, should be considered to ensure accurate clinical interpretation. PMID:26558208

  18. Slit-lamp Needling of the Anterior Capsule for Aqueous Misdirection After Hyaloido-zonulectomy and Iridectomy.

    Science.gov (United States)

    Mardelli, Pierre G; Mardelli, Marc E

    2018-04-01

    We present a case of persistent aqueous misdirection, after Ahmed glaucoma valve surgery, despite undergoing an anterior vitrectomy with hyaloido-zonulectomy and iridectomy. A 73-year-old female patient, 4 months after phacotrabeculectomy, was referred with persistent high intraocular pressure (IOP). Postoperatively, she developed aqueous misdirection with a flat anterior chamber (AC) but with an IOP of 15 mm Hg. On presentation, her AC was shallow with peripheral iris-cornea touch, and her IOP was 39 mm Hg. Posterior Nd:Yag capsulotomy with disruption of anterior hyaloid face partially deepened the AC. With failure of the trabeculectomy and high IOP, an Ahmed valve was placed. On the first operative day the AC was deep with an IOP of 10 mm Hg. On day 6 the patient presented with pain, flat AC, and an IOP of 10 mm Hg. Fundus examination revealed no choroidal effusion. Despite repeated reformation with viscoelastic, the AC failed to deepen. An anterior vitrectomy with hyaloido-zonulectomy was performed. Initially, the AC was deep, but, a few days later, it was flat. Multiple reformations and vitreous tap failed to keep the AC deep. A 30-G needle was passed at the slit lamp across the temporal cornea, iris, and anterior capsule into the anterior vitreous cavity. The needle was then partially withdrawn and used to create a space between the intraocular lens and anterior capsule. This immediately deepened the AC and remained so for the duration of follow-up (4 mo). Slit-lamp needling of the anterior lens capsule can be successfully performed to help resolve a persistent case of aqueous misdirection after anterior vitrectomy.

  19. Characterization of rat model of acute anterior uveitis using optical coherence tomography angiography

    Science.gov (United States)

    Choi, Woo June; Pepple, Kathryn L.; Zhi, Zhongwei; Wang, Ruikang K.

    2015-03-01

    Uveitis, or ocular inflammation, is a cause of severe visual impairment. Rodent models of uveitis are powerful tools used to investigate the pathological mechanisms of ocular inflammation and to study the efficacy of new therapies prior to human testing. In this paper, we report the utility of spectral-domain optical coherence tomography (SD-OCT) angiography in characterizing the inflammatory changes induced in the anterior segment of a rat model of uveitis. Acute anterior uveitis (AAU) was induced in two rats by intravitreal injection of a killed mycobacterial extract. One of them received a concurrent periocular injection of steroids to model a treatment effect. OCT imaging was performed prior to inflammation induction on day 0 (baseline), and 2 days post-injection (peak inflammation). Baseline and inflamed images were compared. OCT angiography identified swelling of the cornea, inflammatory cells in the anterior and posterior chambers, a fibrinous papillary membrane, and dilation of iris vessels in the inflamed eyes when compared to baseline images. Steroid treatment was shown to prevent the changes associated with inflammation. This is a novel application of anterior OCT imaging in animal models of uveitis, and provides a high resolution, in vivo assay for detecting and quantifying ocular inflammation and the response to new therapies.

  20. Ultrasound biomicroscopic evaluation of anterior segment cysts as a risk factor for ocular hypertension and closure angle glaucoma

    Directory of Open Access Journals (Sweden)

    Abdurrahim Dusak

    2013-08-01

    Full Text Available AIM:To investigate the relationship between the ultrasound biomicroscopic (UBM features of anterior-segment cysts (ASCs and increased intraocular pressure (IOP as a risk factor for closed-angle glaucoma (CAG.METHODS:Totally 24 eyes with recently diagnosed ASCs were divided into two groups . First group with ASC and ocular normotension (n=13, second group with ASC and ocular hypertension (n=11. An ophthalmologic examination, including tonometry, slit-lamp biomicroscopy (SLBM, gonioscopy, fundoscopy, pentacam, and UBM, was performed. The features of the ASCs were compared with the IOP.RESULTS:ASCs were accurately diagnosed and delineated in 24 eyes using UBM. IOP was elevated in those ASCs with a secondary aetiology (P=0.027, iridociliary location (P=0.006, deformed shape (P=0.013, increased size (P=0.001 and elongated pupillary aperture (P=0.009. However, the count (P=0.343 of ASCs, anterior chamber depth (ACD; P=0.22 and axial lenght (AL; P=0.31 were not associated with ocular hypertension. Correlations were found between the IOP and ASC size (r=-0.712; P=0.003, anterior chamber angle (ACA; r=-0.985; Pr=0.885; Pr=-0.776, Pr =-0.655, P=0.002.CONCLUSION:Ocular hypertension in some eyes with ASC might be associated with various mechanisms, including secondary aetiology, iridociliary location, deformed shape, increased size and elongated pupill, which can be determined by UBM.

  1. Serial corneal endothelial cell loss with lathe-cut and injection-molded posterior chamber intraocular lenses.

    Science.gov (United States)

    Kraff, M C; Sanders, D R; Lieberman, H L

    1983-01-01

    We compared endothelial cell loss of patients implanted with lathe-cut posterior chamber lenses and those implanted with injection-molded lenses over a three-year postoperative period. Results were based on more than 2,500 measurements of corneal endothelial density. Although the technique of cataract extraction (anterior chamber phacoemulsification, posterior chamber phacoemulsification, or planned extracapsular extraction) significantly affected cell loss (P less than .01), the type of implant (lathe-cut or injection-molded) did not. Significant continuing endothelial cell loss did not occur during the first three postoperative years with injection-molded lenses. There was, however, a statistically significant 7% to 15% additional cell loss after surgery over the first two to three postoperative years with lathe-cut implants. There have been no cases of corneal endothelial decompensation developing after implantation of injection-molded or lathe-cut lenses. Because a standard field clinical specular microscope was used in this study, cell counting errors cannot be ruled out as a cause of these findings.

  2. Role of Scrib and Dlg in anterior-posterior patterning of the follicular epithelium during Drosophila oogenesis

    Directory of Open Access Journals (Sweden)

    Yu Lingzhu

    2009-12-01

    Full Text Available Abstract Background Proper patterning of the follicle cell epithelium over the egg chamber is essential for the Drosophila egg development. Differentiation of the epithelium into several distinct cell types along the anterior-posterior axis requires coordinated activities of multiple signaling pathways. Previously, we reported that lethal(2giant larvae (lgl, a Drosophila tumor suppressor gene, is required in the follicle cells for the posterior follicle cell (PFC fate induction at mid-oogenesis. Here we explore the role of another two tumor suppressor genes, scribble (scrib and discs large (dlg, in the epithelial patterning. Results We found that removal of scrib or dlg function from the follicle cells at posterior terminal of the egg chamber causes a complete loss of the PFC fate. Aberrant specification and differentiation of the PFCs in the mosaic clones can be ascribed to defects in coordinated activation of the EGFR, JAK and Notch signaling pathways in the multilayered cells. Meanwhile, the clonal analysis revealed that loss-of-function mutations in scrib/dlg at the anterior domains result in a partially penetrant phenotype of defective induction of the stretched and centripetal cell fate, whereas specification of the border cell fate can still occur in the most anterior region of the mutant clones. Further, we showed that scrib genetically interacts with dlg in regulating posterior patterning of the epithelium. Conclusion In this study we provide evidence that scrib and dlg function differentially in anterior and posterior patterning of the follicular epithelium at oogenesis. Further genetic analysis indicates that scrib and dlg act in a common pathway to regulate PFC fate induction. This study may open another window for elucidating role of scrib/dlg in controlling epithelial polarity and cell proliferation during development.

  3. Anterior perineal hernia after anterior exenteration

    Directory of Open Access Journals (Sweden)

    Ka Wing Wong

    2017-10-01

    Full Text Available Perineal hernia is a rare complication of anterior exenteration. We reported this complication after an anterior exenteration for bladder cancer with bleeding complication requiring packing and second-look laparotomy. Perineal approach is a simple and effective method for repair of perineal hernia.

  4. Ionization chamber

    International Nuclear Information System (INIS)

    Jilbert, P.H.

    1975-01-01

    The invention concerns ionization chambers with particular reference to air-equivalent ionization chambers. In order to ensure that similar chambers have similar sensitivities and responses the surface of the chamber bounding the active volume carries a conducting material, which may be a colloidal graphite, arranged in the form of lines so that the area of the conducting material occupies only a small proportion of the area of said surface. (U.S.)

  5. Segmentation and Quantification for Angle-Closure Glaucoma Assessment in Anterior Segment OCT.

    Science.gov (United States)

    Fu, Huazhu; Xu, Yanwu; Lin, Stephen; Zhang, Xiaoqin; Wong, Damon Wing Kee; Liu, Jiang; Frangi, Alejandro F; Baskaran, Mani; Aung, Tin

    2017-09-01

    Angle-closure glaucoma is a major cause of irreversible visual impairment and can be identified by measuring the anterior chamber angle (ACA) of the eye. The ACA can be viewed clearly through anterior segment optical coherence tomography (AS-OCT), but the imaging characteristics and the shapes and locations of major ocular structures can vary significantly among different AS-OCT modalities, thus complicating image analysis. To address this problem, we propose a data-driven approach for automatic AS-OCT structure segmentation, measurement, and screening. Our technique first estimates initial markers in the eye through label transfer from a hand-labeled exemplar data set, whose images are collected over different patients and AS-OCT modalities. These initial markers are then refined by using a graph-based smoothing method that is guided by AS-OCT structural information. These markers facilitate segmentation of major clinical structures, which are used to recover standard clinical parameters. These parameters can be used not only to support clinicians in making anatomical assessments, but also to serve as features for detecting anterior angle closure in automatic glaucoma screening algorithms. Experiments on Visante AS-OCT and Cirrus high-definition-OCT data sets demonstrate the effectiveness of our approach.

  6. Glove box chamber

    International Nuclear Information System (INIS)

    Cox, M.E.; Cox, M.E.

    1975-01-01

    An environmental chamber is described which enables an operator's hands to have direct access within the chamber without compromising a special atmosphere within such chamber. A pair of sleeves of a flexible material are sealed to the chamber around associated access apertures and project outwardly from such chamber. Each aperture is closed by a door which is openable from within the sleeve associated therewith so that upon an operator inserting his hand and arm through the sleeve, the operator can open the door to have access to the interior of the chamber. A container which is selectively separable from the remainder of the chamber is also provided to allow objects to be transferred from the chamber without such objects having to pass through the ambient atmosphere. An antechamber permitting objects to be passed directly into the chamber from the ambient atmosphere is included. (auth)

  7. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  8. Test chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2009-01-01

    A test chamber for measuring electromagnetic radiation emitted by an apparatus to be tested or for exposing an apparatus to be tested to an electromagnetic radiation field. The test chamber includes a reverberation chamber made of a conductive tent fabric. To create a statistically uniform field in

  9. Analysis of low-energy and high-frequency femtosecond laser for the construction of deep anterior donor corneal lamellae

    Directory of Open Access Journals (Sweden)

    Gustavo Victor

    2014-04-01

    Full Text Available Purpose: To evaluate the efficacy and reliability of a low-energy femtosecond laser with a high repetition rate for construction of deep anterior donor corneal lamellae. Methods: This was a prospective laboratory investigation. Twenty-five human corneal buttons were femtosecond laser cut to create thick anterior lamellae (diameter, 10mm; thickness, 500µm. The laser cuts were made using an LDV® femtosecond laser in a Ziemer® anterior chamber. To obtain a better edge, the lamellae were trephined with an 8mm trephine (Katena®. The central corneal thickness and the anterior lamellae were measured using a Mitutoyo® thickness gauge with an accuracy of 0.001mm. Results: The central thickness of the 25 corneas ranged from 500 to 705µm (mean, 584 ± 51µm. The thickness of the anterior lamellae ranged from 420 to 480µm (mean, 455 ± 12.7µm. The anterior lamellae diameters were 7.90 ± 0.1mm, and all laser cuts were round. The lamellar interfaces appeared regular by surgical microscopy. There were no cases of inter-lamellar adhesion. Conclusion: The LDV® femtosecond laser appears to be a safe and reliable instrument for cutting deep anterior lamellae from donor corneoscleral buttons. Minimal variation in donor lamellar depth with the laser will be useful for creating donor corneal tissue for deeper anterior lamellar keratoplasty or endothelial keratoplasty surgery or both from a single donor cornea.

  10. Excitatory and inhibitory effects of prolactin release activated by nerve stimulation in rat anterior pituitary

    Directory of Open Access Journals (Sweden)

    Gao Li-Zhi

    2009-12-01

    Full Text Available Abstract Background A series of studies showed the presence of substantial amount of nerve fibers and their close relationship with the anterior pituitary gland cells. Our previous studies have suggested that aside from the classical theory of humoral regulation, the rat anterior pituitary has direct neural regulation on adrenocorticotropic hormone release. In rat anterior pituitary, typical synapses are found on every type of the hormone-secreting cells, many on lactotrophs. The present study was aimed at investigating the physiological significance of this synaptic relationship on prolactin release. Methods The anterior pituitary of rat was sliced and stimulated with electrical field in a self-designed perfusion chamber. The perfusate was continuously collected in aliquots and measured by radioimmunoassay for prolactin levels. After statistic analysis, differences of prolactin concentrations within and between groups were outlined. Results The results showed that stimulation at frequency of 2 Hz caused a quick enhancement of prolactin release, when stimulated at 10 Hz, prolactin release was found to be inhibited which came slower and lasted longer. The effect of nerve stimulation on prolactin release is diphasic and frequency dependent. Conclusions The present in vitro study offers the first physiological evidence that stimulation of nerve fibers can affect prolactin release in rat anterior pituitary. Low frequency stimulation enhances prolactin release and high frequency mainly inhibits it.

  11. Swimming mechanics and propulsive efficiency in the chambered nautilus

    Science.gov (United States)

    Neil, Thomas R.; Askew, Graham N.

    2018-02-01

    The chambered nautilus (Nautilus pompilius) encounters severe environmental hypoxia during diurnal vertical movements in the ocean. The metabolic cost of locomotion (Cmet) and swimming performance depend on how efficiently momentum is imparted to the water and how long on-board oxygen stores last. While propulsive efficiency is generally thought to be relatively low in jet propelled animals, the low Cmet in Nautilus indicates that this is not the case. We measured the wake structure in Nautilus during jet propulsion swimming, to determine their propulsive efficiency. Animals swam with either an anterior-first or posterior-first orientation. With increasing swimming speed, whole cycle propulsive efficiency increased during posterior-first swimming but decreased during anterior-first swimming, reaching a maximum of 0.76. The highest propulsive efficiencies were achieved by using an asymmetrical contractile cycle in which the fluid ejection phase was relatively longer than the refilling phase, reducing the volume flow rate of the ejected fluid. Our results demonstrate that a relatively high whole cycle propulsive efficiency underlies the low Cmet in Nautilus, representing a strategy to reduce the metabolic demands in an animal that spends a significant part of its daily life in a hypoxic environment.

  12. Assessment of narrow angles by gonioscopy, Van Herick method and anterior segment optical coherence tomography.

    Science.gov (United States)

    Park, Seong Bae; Sung, Kyung Rim; Kang, Sung Yung; Jo, Jung Woo; Lee, Kyoung Sub; Kook, Michael S

    2011-07-01

    To evaluate anterior chamber (AC) angles using gonioscopy, Van Herick technique and anterior segment optical coherence tomography (AS-OCT). One hundred forty-eight consecutive subjects were enrolled. The agreement between any two of three diagnostic methods, gonioscopy, AS-OCT and Van Herick, was calculated in narrow-angle patients. The area under receiver-operating characteristic curves (AUC) for discriminating between narrow and open angles determined by gonioscopy was calculated in all participants for AS-OCT parameter angle opening distance (AOD), angle recess area, trabecular iris surface area and anterior chamber depth (ACD). As a subgroup analysis, capability of AS-OCT parameters for detecting angle closure defined by AS-OCT was assessed in narrow-angle patients. The agreement between the Van Herick method and gonioscopy in detecting angle closure was excellent in narrow angles (κ = 0.80, temporal; κ = 0.82, nasal). However, agreement between gonioscopy and AS-OCT and between the Van Herick method and AS-OCT was poor (κ = 0.11-0.16). Discrimination capability of AS-OCT parameters between open and narrow angles determined by gonioscopy was excellent for all AS-OCT parameters (AUC, temporal: AOD500 = 0.96, nasal: AOD500 = 0.99). The AUCs for detecting angle closure defined by AS-OCT image in narrow angle subjects was good for all AS-OCT parameters (AUC, 0.80-0.94) except for ACD (temporal: ACD = 0.70, nasal: ACD = 0.63). Assessment of narrow angles by gonioscopy and the Van Herick technique showed good agreement, but both measurements revealed poor agreement with AS-OCT. The angle closure detection capability of AS-OCT parameters was excellent; however, it was slightly lower in ACD.

  13. The Mobile Chamber

    Science.gov (United States)

    Scharfstein, Gregory; Cox, Russell

    2012-01-01

    A document discusses a simulation chamber that represents a shift from the thermal-vacuum chamber stereotype. This innovation, currently in development, combines the capabilities of space simulation chambers, the user-friendliness of modern-day electronics, and the modularity of plug-and-play computing. The Mobile Chamber is a customized test chamber that can be deployed with great ease, and is capable of bringing payloads at temperatures down to 20 K, in high vacuum, and with the desired metrology instruments integrated to the systems control. Flexure plans to lease Mobile Chambers, making them affordable for smaller budgets and available to a larger customer base. A key feature of this design will be an Apple iPad-like user interface that allows someone with minimal training to control the environment inside the chamber, and to simulate the required extreme environments. The feedback of thermal, pressure, and other measurements is delivered in a 3D CAD model of the chamber's payload and support hardware. This GUI will provide the user with a better understanding of the payload than any existing thermal-vacuum system.

  14. Antioxidant status of dog aqueous humor after extracapsular lens extraction

    Directory of Open Access Journals (Sweden)

    Barros P.S.M.

    2003-01-01

    Full Text Available We determined the antioxidant status of the aqueous humor after extracapsular lens extraction in 14 mongrel dogs weighing about 10 kg. The animals were examined by slit lamp biomicroscopy, applanation tonometry and indirect ophthalmoscopy. One eye was submitted to conventional extracapsular lens extraction and the other was used as control. Samples of aqueous humor were obtained by anterior chamber paracentesis before and at days 1, 2, 3, 7 and 15 after surgery. Total antioxidant status was determined as the capacity of aqueous humor to inhibit free radical generation by 2,2-azobis(2-amidopropane chlorine. Ascorbic acid concentration was measured by HPLC with UV detection. Protein content was determined with the biuret reagent. Statistical analysis was performed by ANOVA followed by the Tukey-Kramer test. Protein concentration increased from 0.61 to 22 mg/ml 24 h after surgery. These levels were maintained and returned to normal at day 7. Total antioxidant capacity was reduced from 50 to about 30 min until day 3 and at day 7 it was equal to control. Ascorbic acid levels were reduced from 252 to about 110 µM and then returned to control values at day 15. Considering the importance of ascorbic acid concentration in aqueous humor for the maintenance of the antioxidant status of the anterior segment of the eye, the decrease of antioxidant defenses suggests that the surgical procedures promote an oxidative stress condition in the eye.

  15. Morphological studies on the Gaseous Chambers of the African-Catfish (Clarias gariepinus

    Directory of Open Access Journals (Sweden)

    Eman A. Eshra

    2015-04-01

    Full Text Available This study aimed to find out the morpho-functional correlations of supra-branchial gaseous chambers (SC and gas bladder (GB in Clarias gariepinus. Gross, and Histological observations were made on ten different ontogenetic stages ranged from 10 mm SL (Standard length to 100 mm SL, and mature fish 330 mm-333 mm SL. Computed tomography (CT was performed on five mature fishes at 130 K Volt and 80 Ma, different CT windows were adjusted as follows: Soft tissue (WL: 40, WW: 300, Bone (2000: 400, and Air-chambers (-600:1200. Each SC lodged mid-constricted membranous sac, communicated to gill cavity via single opening. The GB was an oval sac surrounded by incomplete bony capsule, it touched the skin laterally, otic capsule medially and SC anteriorly. The SC membrane was three layered with a gill like mucosa (respiratory mucosa; GB has an inner layer of simple squamous epithelium and an outer layer of dense irregular connective tissue. Collectively, the larval stages were adult like, but differ in proportions; in stages from 10 to 26 mm, SC adventitia was ill defined or absent and SC musculosa was well developed relatively to the total thickness of the membrane. In CT images, there was a clear communication between the otic capsule and GB at the level of anterior-medial fissures of complex vertebra; disc–shaped fat pads appeared as hypodense bilateral areas dorso-medial to GB and caudo-posterior to SC. Results Concluded that GB and SC had an accessory auditory role related to their anatomical structure, position and communications.

  16. Chylous ascites occurring after low anterior resection of the rectum successfully treated with an oral fat-free elemental diet (Elental(®)).

    Science.gov (United States)

    Nakayama, Gakuryu; Morioka, Daisuke; Murakami, Takashi; Takakura, Hideki; Miura, Yasuhiko; Togo, Shinji

    2012-06-01

    Chylous ascites occurring after abdominal surgery is rare. Despite being potentially critical, there is no definite treatment guideline because of its rarity. Here we present a case of massive chylous ascites occurring after rectal surgery which was successfully treated with an oral fat-free elemental diet (ED). A 67-year-old man underwent low anterior resection with para-aortic lymphadenectomy for advanced rectal cancer. Early postoperative course was uneventful and the patient was discharged from hospital 10 days after surgery; however, after discharge, abdominal distension rapidly developed. Abdominal computed tomography (CT) performed 3 weeks after surgery revealed massive ascites and laboratory findings showed remarkable hypoproteinemia and lymphopenia. Urgent diagnostic paracentesis showed the ascites to be a white milky fluid containing high levels of triglycerides (564 mg/dl), leading to a diagnosis of chyloperitoneum. Daily nutrition of the patient was entirely with a fat-free ED (30 kcal/kg/day of Elental(®), Ajinomoto Pharmaceutical Co. Ltd, Tokyo, Japan). After the initiation of oral Elental(®), abdominal distension, hypoproteinemia, and lymphopenia gradually improved. Abdominal CT performed 7 weeks after surgery showed no ascitic fluid in the abdomen, and thereafter a normal diet was initiated. Since then, no relapse of chyloperitoneum has been proven. As a result, the chylous ascites was successfully treated in the outpatient clinic.

  17. Drift chamber

    International Nuclear Information System (INIS)

    Inagaki, Yosuke

    1977-01-01

    Drift chamber is becoming an important detector in high energy physics as a precision and fast position detector because of its high spatial resolution and count-rate. The basic principle is that it utilizes the drift at constant speed of electrons ionized along the tracks of charged particles towards the anode wire in the nearly uniform electric field. The method of measuring drift time includes the analog and digital ones. This report describes about the construction of and the application of electric field to the drift chamber, mathematical analysis on the electric field and equipotential curve, derivation of spatial resolution and the factor for its determination, and selection of gas to be used. The performance test of the chamber was carried out using a small test chamber, the collimated β source of Sr-90, and 500 MeV/C electron beam from the 1.3 GeV electron synchrotron in the Institute of Nuclear Study, University of Tokyo. Most chambers to date adopted one dimensional read-out, but it is very advantageous if the two dimensional read-out is feasible with one chamber when the resolution in that direction is low. The typical methods of delay line and charge division for two dimensional read-out are described. The development of digital read-out system is underway, which can process the signal of a large scale drift chamber at high speed. (Wakatsuki, Y.)

  18. Mechanistic modeling of ophthalmic drug delivery to the anterior chamber by eye drops and contact lenses.

    Science.gov (United States)

    Gause, Samuel; Hsu, Kuan-Hui; Shafor, Chancellor; Dixon, Phillip; Powell, Kristin Conrad; Chauhan, Anuj

    2016-07-01

    Ophthalmic drug for the anterior chamber diseases are delivered into tears by either eye drops or by extended release devices placed in the eyes. The instilled drug exits the eye through various routes including tear drainage into the nose through the canaliculi and transport across various ocular membranes. Understanding the mechanisms relevant to each route can be useful in predicting the dependency of ocular bioavailability on various formulation parameters, such as drug concentration, salinity, viscosity, etc. Mathematical modeling has been developed for each of the routes and validated by comparison with experiments. The individual models can be combined into a system model to predict the fraction of the instilled drug that reaches the target. This review summarizes the individual models for the transport of drugs across the cornea and conjunctiva and the canaliculi tear drainage. It also summarizes the combined tear dynamics model that can predict the ocular bioavailability of drugs instilled as eye drops. The predictions from the individual models and the combined model are in good agreement with experimental data. Both experiments and models predict that the corneal bioavailability for drugs delivered through eye drops is less than 5% due to the small area of the cornea in comparison to the conjunctiva, and the rapid clearance of the instilled solution by tear drainage. A contact lens is a natural choice for delivering drugs to the cornea due to the placement of the contact in the immediate vicinity of the cornea. The drug released by the contact towards the cornea surface is trapped in the post lens tear film for extended duration of at least 30min allowing transport of a large portion into the cornea. The model predictions backed by in vivo animal and clinical data show that the bioavailability increases to about 50% with contact lenses. This realization has encouraged considerable research towards delivering ocular drugs by contact lenses. Commercial

  19. Multiple chamber ionization detector

    International Nuclear Information System (INIS)

    Solomon, E.E.

    1980-01-01

    A multi-chambered ionisation detector enables the amount of radiation entering each chamber from a single radioactive, eg β, source to be varied by altering the proportion of the source protruding into each chamber. Electrodes define chambers and an extended radioactive source is movable to alter the source length in each chamber. Alternatively, the source is fixed relative to outer electrodes but the central electrode may be adjusted by an attached support altering the chamber dimensions and hence the length of source in each. Also disclosed are a centrally mounted source tiltable towards one or other chamber and a central electrode tiltable to alter chamber dimensions. (U.K.)

  20. Anterior cervical fusion: the role of anterior plating.

    Science.gov (United States)

    Daffner, Scott D; Wang, Jeffrey C

    2009-01-01

    Treatment of cervical pathology requires a clear understanding of the biomechanical benefits and limitations of cervical plates, their indications, and their associated complications. The use of anterior cervical plates has evolved significantly since their early application in cervical trauma. They have become widely used for anterior cervical decompression and fusion for cervical spondylosis. Plate design has undergone significant refinement and innovation, from the initial unlocked plates requiring bicortical purchase to the latest rotationally and translationally semiconstrained dynamic plates. Excellent clinical results have been reported for single-level anterior cervical decompression and fusion with or without plate fixation; however, the addition of an anterior cervical plate clearly leads to earlier fusion and better clinical results in longer fusions. Longer fusions should ideally consist of corpectomies and strut grafting because the decreased number of fusion surfaces tends to lead to higher fusion rates. Although anterior plate fixation leads to higher fusion rates in fusions of three or more levels, the associated pseudarthrosis rate is still high. The use of dynamic plates, through increased load sharing across the graft and decreased stress shielding, may improve fusion rates, particularly in long fusions. Nevertheless, adjuvant posterior fixation is recommended for fusions of more than three vertebral levels. Anterior plate fixation may be of particular benefit in the management of traumatic injuries, in revision settings, and in the treatment of smokers. Complications unique to plate fixation include hardware breakage and migration as well as ossification of the adjacent disk levels.

  1. Utility of bleb imaging with anterior segment optical coherence tomography in clinical decision-making after trabeculectomy.

    Science.gov (United States)

    Singh, Mandeep; Aung, Tin; Aquino, Maria C; Chew, Paul T K

    2009-08-01

    To determine if imaging of blebs with anterior segment optical coherence tomography (ASOCT) affects clinical decision-making with regard to laser suture lysis (LSL) after trabeculectomy. In this prospective observational case series, we included patients with poorly controlled intraocular pressure (IOP) after standardized trabeculectomy from May to November 2006. One observer assessed IOP, anterior chamber depth and bleb formation, and recorded a decision of whether or not to undertake LSL based on clinical grounds. A second observer masked to clinical data recorded a decision of whether or not to perform LSL based on ASOCT assessment of scleral flap position, presence of a sub-flap space, patency of the internal ostium, and bleb wall thickening. We compared the 2 observers' decisions to determine how ASOCT influenced decision-making. Seven eyes of 7 patients were included. On the basis of clinical examination, LSL was recommended in all 7 (100.0%) cases due to presence of elevated IOP, deep anterior chambers and poorly formed blebs. Using ASOCT, LSL was recommended in 5/7 (71.4%) cases with apposed scleral flaps, absent sub-flap spaces, and absent bleb wall thickening. In 2/7 (28.7%) cases, LSL was not recommended based on ASOCT findings of an elevated scleral flap, a patent sub-flap space, and bleb wall thickening. All 7 patients had good IOP control and formed blebs at a mean of 8.4+/-2.6 months after trabeculectomy, with a mean IOP of 14.3+/-3.2 mm Hg with no medications. This small study suggests that ASOCT imaging may affect decision-making with regard to LSL by providing information not apparent on clinical examination.

  2. Doriot Climatic Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — The Doriot Climatic Chambers are two, 60-feet long, 11-feet high, 15-feet wide chambers that are owned and operated by NSRDEC. The Doriot Climatic Chambers are among...

  3. Ionization chamber

    International Nuclear Information System (INIS)

    1977-01-01

    An improved ionization chamber type X-ray detector comprises a heavy gas at high pressure disposed between an anode and a cathode. An open grid structure is placed next to the anode and is maintained at a voltage intermediate between the cathode and anode potentials. The electric field which is produced by positive ions drifting towards the cathode is thus shielded from the anode. Current measuring circuits connected to the anode are, therefore, responsive only to electron current flow within the chamber and the recovery time of the chamber is shortened. The grid structure also serves to shield the anode from electrical currents which might otherwise be induced by mechanical vibrations in the ionization chamber structure

  4. Anterior vaulting of single piece in-the-bag intraocular lens after blunt trauma

    Directory of Open Access Journals (Sweden)

    Seung Hoon Oh

    2012-01-01

    Full Text Available A 64-year-old man complained of difficulty with far vision in the right eye after blunt trauma by his hand during sleep. He had undergone uneventful phacoemulsification and intraocular lens (IOL implantation of both eyes one week before the event. On slit lamp examination, the anterior chamber was shallow compared to postoperative one day or the left eye. After mydriasis, IOL position was perfect, within the capsulorrhexis margin, and no haptics were protruded. SE of his right eye was −4.00 diopter after trauma, although spherical equivalent (SE of both eyes was near emmetropia one day after cataract surgery. We decided on IOL reposition or exchange. Intraoperatively, we pushed the IOL posteriorly; the IOL was vaulted posteriorly, as expected. After surgery, his SE was +0.25 with the same diopter IOL. We report the case on the possibility of 4-point haptic IOL vaulting anteriorly by blunt trauma within the capsular bag.

  5. Pars-plana fluid aspiration for positive vitreous cavity pressure in anterior segment surgeries

    Directory of Open Access Journals (Sweden)

    Thomas Kuriakose

    2018-01-01

    Full Text Available Positive vitreous pressure due to misdirection of aqueous or choroidal effusion leads to shallowing of the anterior chamber (AC before or during anterior segment surgeries. This shallow AC if not addressed makes surgery difficult and increases the risk of surgical complications. Methods to prevent and manage this condition described in literature are not without problems. We describe a minimally invasive technique of passing a 30G needle through the pars-plana to aspirate misdirected fluid from vitreous cavity either as a prophylaxis just before surgery or during it, thereby decreasing positive vitreous pressure. This technique, used in 12 eyes, seems to be effective in patients with angle-closure glaucoma, malignant glaucoma, and per-operative sudden increase in vitreous pressure during surgery. Small-incision surgeries are ideally suited for this procedure. This minimally invasive technique is simple to perform and complications are unlikely to be more than what is seen with intravitreal injections.

  6. Peltier-based cloud chamber

    Science.gov (United States)

    Nar, Sevda Yeliz; Cakir, Altan

    2018-02-01

    Particles produced by nuclear decay, cosmic radiation and reactions can be identified through various methods. One of these methods that has been effective in the last century is the cloud chamber. The chamber makes visible cosmic particles that we are exposed to radiation per second. Diffusion cloud chamber is a kind of cloud chamber that is cooled by dry ice. This traditional model has some application difficulties. In this work, Peltier-based cloud chamber cooled by thermoelectric modules is studied. The new model provided uniformly cooled base of the chamber, moreover, it has longer lifetime than the traditional chamber in terms of observation time. This gain has reduced the costs which spent each time for cosmic particle observation. The chamber is an easy-to-use system according to traditional diffusion cloud chamber. The new model is portable, easier to make, and can be used in the nuclear physics experiments. In addition, it would be very useful to observe Muons which are the direct evidence for Lorentz contraction and time expansion predicted by Einsteins special relativity principle.

  7. anomalous left anterior cerebral artery with hypoplastic right anterior ...

    African Journals Online (AJOL)

    2018-02-28

    Feb 28, 2018 ... We report an extremely rare anomalous variation of left anterior cerebral artery arising from the ... paraclinoid internal carotid artery and right ... Studies on the arteries of the brain: II-The anterior cerebral artery: Some anatomic ...

  8. Comparative Evaluation of the Corneal and Anterior Chamber Parameters Derived From Scheimpflug Imaging in Arab and South Asian Normal Eyes.

    Science.gov (United States)

    Prakash, Gaurav; Srivastava, Dhruv; Avadhani, Kavitha; Thirumalai, Sandeep M; Choudhuri, Sounak

    2015-11-01

    To evaluate the differences in the normal corneal and anterior segment Scheimpflug parameters in Arab and South Asian eyes. This hospital-based study was performed at a cornea and refractive surgery service in Abu Dhabi. A total of 600 consecutive normal candidates of South Asian (group 1, n = 300) and Arab (group 2, n = 300) origins underwent Scheimpflug imaging (Sirius; Costruzione Strumenti Oftalmici, Italy). One eye was randomly selected for evaluation. The age and sex distributions in both groups were comparable. The pachymetric variables were statistically higher in group 2 (group 2 vs. group 1, 544.3 ± 32.2 μm vs. 535.1 ± 31.4 μm for central corneal thickness, 541.0 ± 32.6 μm vs. 531.9 ± 31.5 μm for minimum corneal thickness, 571.7 ± 43.2 μm vs. 558.1 ± 42.3 μm for apical thickness, and 58.1 ± 4.2 vs. 57.3 ± 4.3 mm³ for the corneal volume; P Arab ethnicity tend to have statistically thicker and flatter corneas and less-crowded anterior segments than those of the South Asian counterparts. These epidemiological differences have a mild to moderate biological effect size (Cohen d), but they should be considered when evaluating these eyes for anterior segment or corneal procedures.

  9. Dual ionization chamber

    International Nuclear Information System (INIS)

    Mallory, J.; Turlej, Z.

    1981-01-01

    Dual ionization chambers are provided for use with an electronic smoke detector. The chambers are separated by electrically-conductive partition. A single radiation source extends through the partition into both chambers, ionizing the air in each. The mid-point current of the device may be balanced by adjusting the position of the source

  10. Transthoracic ultrasonic tissue indices identify patients with severe left anterior descending artery stenosis. Correlation with fractional flow reserve. Pilot study.

    Science.gov (United States)

    Dobrowolski, Piotr; Kowalski, Mirosław; Rybicka, Justyna; Lech, Agnieszka; Tyczyński, Paweł; Witkowski, Adam; Hoffman, Piotr

    2016-01-01

    The aim of this study was to evaluate the potential clinical application of ultrasonic tissue indices, with a focus on systolic strain (SS) and systolic strain rate (SSR) parameters derived from transthoracic echocardiography, in the assessment of left anterior descending artery (LAD) stenosis. The data of 30 patients with significant LAD stenosis were analysed. All patients underwent transthoracic echocardiography to obtain systolic myocardial velocity (Sm), longitudinal SS, and SSR from basal, mid, and apical segments of anterior and inferior walls in two-chamber apical view. Severity of LAD obstruction was measured by means of fractional flow reserve (FFR) during coronary catheterisation. Systolic velocities, strain, and strain rate measured in basal, middle, and apical segments of the anterior left ventricular (LV) wall were lower when compared to those obtained from the corresponding, i.e. unaffected, inferior LV wall. There was a significant correlation between FFR and the value of SS, SSR characterising the apical LV segment of the anterior wall (r = -0.583, p = 0.01; r = -0.598, p = 0.01, respectively). Moreover, we found significant correlation between FFR and Sm in the mid-segment of the LV anterior wall (r = 0.611, p = 0.009). We conclude that SS and SSR obtained from the apical segment of the anterior LV wall may be related to the severity of LAD stenosis.

  11. Effects of primary selective laser trabeculoplasty on anterior segment parameters

    Directory of Open Access Journals (Sweden)

    Suzan Guven Yilmaz

    2015-10-01

    Full Text Available AIM:To investigate the effects of selective laser trabeculoplasty (SLT on the main numerical parameters of anterior segment with Pentacam rotating Scheimpflug camera in patients with ocular hypertension (OHT and primary open angle glaucoma (POAG.METHODS: Pentacam measurements of 45 eyes of 25 (15 females and 10 males patients (12 with OHT, 13 with POAG before and after SLT were obtained. Measurements were taken before and 1 and 3mo after SLT. Pentacam parameters were compared between OHT and POAG patients, and age groups (60y and older, and younger than 60y.RESULTS: The mean age of the patients was 57.8±13.9 (range 20-77y. Twelve patients (48% were younger than 60y, while 13 patients (52% were 60y and older. Measurements of pre-SLT and post-SLT 1mo were significantly different for the parameters of central corneal thickness (CCT and anterior chamber volume (ACV (P<0.05. These parameters returned back to pre-SLT values at post-SLT 3mo. Decrease of ACV at post-SLT 1mo was significantly higher in younger than 60y group than 60y and older group. There was no statistically significant difference in Pentacam parameters between OHT and POAG patients at pre- and post-treatment measurements (P>0.05.CONCLUSION:SLT leads to significant increase in CCT and decrease in ACV at the 1st month of the procedure. Effects of SLT on these anterior segment parameters, especially for CCT that interferes IOP measurement, should be considered to ensure accurate clinical interpretation.

  12. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  13. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  14. Ionization chambers

    International Nuclear Information System (INIS)

    Boag, J.W.

    1987-01-01

    Although a variety of solid-state and chemical methods for measuring radiation dose have been developed in recent decades and calorimetry can now provide an absolute standard of reference, ionization dosimetry retains its position as the most widely used, most convenient, and, in most situations, most accurate method of measuring either exposure or absorbed dose. The ionization chamber itself is the central element in this system of dosimetry. In this chapter the principles governing the construction and operation of ionization chambers of various types are examined. Since the ionization chambers now in general use are nearly all of commercial manufacture, the emphasis is on operating characteristics and interpretation of measurements rather than on details of construction, although some knowledge of the latter is often required when applying necessary corrections to the measured quantities. Examples are given of the construction of typical chambers designed for particular purposes, and the methods of calibrating them are discussed

  15. Gas microstrip chambers

    International Nuclear Information System (INIS)

    McIntyre, P.M.; Barasch, E.F.; Bowcock, T.J.V.; Demroff, H.P.; Elliott, S.M.; Howe, M.R.; Lee, B.; Mazumdar, T.K.; Pang, Y.; Smith, D.D.; Wahl, J.; Wu, Y.; Yue, W.K.; Gaedke, R.M.; Vanstraelen, G.

    1992-01-01

    The gas microstrip chamber has been developed from concept to experimental system during the past three years. A pattern of anode and grid lines are microfabricated onto a dielectric substrate and configured as a high-resolution MWPC. Four recent developments are described: Suitable plastic substrates and lithography techniques for large-area chambers; non-planar silicon-based chambers for 20 μm resolution; integrated on-board synchronous front-end electronics and data buffering; and a porous silicon active cathode for enhanced efficiency and time response. The microstrip chamber appears to be a promising technology for applications in microvertex, tracking spectrometer, muon spectrometer, and transition radiation detection. (orig.)

  16. Double chamber ion source

    International Nuclear Information System (INIS)

    Uman, M.F.; Winnard, J.R.; Winters, H.F.

    1978-01-01

    The ion source is comprised of two discharge chambers one of which is provided with a filament and an aperture leading into the other chamber which in turn has an extraction orifice. A low voltage arc discharge is operated in an inert gas atmosphere in the filament chamber while an arc of higher voltage is operated in the second ionization chamber which contains a vapor which will give the desired dopant ion species. The entire source is immersed in an axial magnetic field parallel to a line connecting the filament, the aperture between the two chambers and the extraction orifice. (author)

  17. Válvula de uretra anterior Anterior urethral valves

    Directory of Open Access Journals (Sweden)

    Silvio Tucci Jr.

    2003-02-01

    Full Text Available Objetivo: apresentar os aspectos clínicos, diagnósticos e terapêuticos de pacientes portadores de válvula da uretra anterior. Descrição: em dois neonatos, o diagnóstico presuntivo de patologia obstrutiva do trato urinário foi sugerido pela ultra-sonografia realizada no período pré-natal, confirmando-se o diagnóstico de válvula de uretra anterior pela avaliação pós-natal. Os pacientes foram submetidos a tratamento cirúrgico paliativo, com vesicostomia temporária e, posteriormente, definitivo, pela fulguração endoscópica das válvulas. Ambos evoluíram com função renal normal. Comentários: a válvula da uretra anterior é anomalia rara que deve ser considerada em meninos com quadro radiológico pré-natal sugestivo de obstrução infravesical, secundariamente à hipótese mais comum de válvula da uretra posterior. Ressaltamos a utilização da vesicostomia como derivação urinária temporária nestes casos, prevenindo potenciais complicações pela manipulação da uretra do recém-nascido.Objective: to discuss clinical signs, diagnostic tools and therapeutics of anterior urethral valves, an obstructive anomaly of the urinary system in males. Description: signs of urinary tract obstruction were identified on pre-natal ultrasound in two male fetuses and the diagnosis of anterior urethral valves was made through post-natal evaluation. As an initial treatment, vesicostomy was performed in both patients. Later, the valves were fulgurated using an endoscopic procedure. During the follow-up period both patients presented normal renal function. Comments: anterior urethral valves are a rare form of urethral anomaly that must be ruled out in boys with pre-natal ultrasound indicating infravesical obstruction. Vesicostomy used as an initial treatment rather than transurethral fulguration may prevent potential complications that can occur due to the small size of the neonatal urethra.

  18. Ussing Chamber

    NARCIS (Netherlands)

    Westerhout, J.; Wortelboer, H.; Verhoeckx, K.

    2015-01-01

    The Ussing chamber system is named after the Danish zoologist Hans Ussing, who invented the device in the 1950s to measure the short-circuit current as an indicator of net ion transport taking place across frog skin (Ussing and Zerahn, Acta Physiol Scand 23:110-127, 1951). Ussing chambers are

  19. Perawatan Ortodontik Gigitan Terbuka Anterior

    Directory of Open Access Journals (Sweden)

    Yuniar Zen

    2014-06-01

    Full Text Available Perawatan gigitan terbuka anterior telah lama dianggap sebagai tantangan bagi ortodontis. Prevalensi gigitan terbuka anterior antara 3,5% hingga 11% terdapat pada berbagai usia dan kelompok etnis, serta ada sekitar 17% pasien ortodonti memiliki gigitan terbuka. Stabilitas hasil perawatan gigitan terbuka anterior sangat sulit, karena adanya kombinasi diskrepansi anteroposterior dengan gigitan terbuka skeletal sehingga dibutuhkan tingkat keterampilan diagnosis dan klinis yang tinggi. Etiologi gigitan terbuka anterior sangat kompleks karena dapat melibatkan skeletal, dental, dan faktor-faktor habitual. Eliminasi faktor etiologi merupakan hal yang penting dalam perawatan gigitan terbuka anterior. Berbagai cara perawatan untuk koreksi gigitan terbuka anterior diantaranya bedah ortognatik dan perawatan ortodontik kamuflase, seperti high-pull headgear, chincup, bite blocks, alatfungsional, pencabutan gigi, multi-loop edgewise archwires dan mini implan. Stabilitas hasil perawatan adalah kriteria yang paling penting dalam menentukan cara perawatan gigitan terbuka anterior. Orthodontic Treatment of Anterior Open Bite. An anterior open bite therapy has long been considered a challenge to orthodontist. The prevalence of anterior openbite range from 3,5 % to 11% among various age and ethnic groups and it has been shown that approximately 17% of orthodontic patients have open bite. Stability of treatment result of anterior open bite with well-maintained results is difficult, because the combination of anteroposteriorly discrepancy with skeletal open bite requires the highest degree of diagnostic and clinical skill. The etiology is complex, potentially involving skeletal, dental and habitual factors. The importance of an anterior open bite therapy is to eliminate the cause of the open bite. Various treatment modalities for the correction of an anterior open bite have been proposed, orthognatic surgery and orthodontic camouflage treatment such as high

  20. DELPHI Barrel Muon Chamber Module

    CERN Multimedia

    1989-01-01

    The module was used as part of the muon identification system on the barrel of the DELPHI detector at LEP, and was in active use from 1989 to 2000. The module consists of 7 individual muons chambers arranged in 2 layers. Chambers in the upper layer are staggered by half a chamber width with respect to the lower layer. Each individual chamber is a drift chamber consisting of an anode wire, 47 microns in diameter, and a wrapped copper delay line. Each chamber provided 3 signal for each muon passing through the chamber, from which a 3D space-point could be reconstructed.

  1. Pseudophakic hyperopia in nanophthalmic eyes managed by a posterior chamber implantable collamer lens

    Directory of Open Access Journals (Sweden)

    Kothari Kulin

    2011-01-01

    Full Text Available We report a case of a bilateral posterior chamber implantable collamer lens (ICL implantation post-clear lens extraction, to reduce the residual hyperopia, in a patient with nanophthalmic eyes. A 30-year-old female patient, keen to reduce her dependency on glasses and contact lenses, came to our refractive surgery department. Her refractive error was +12.0 and +12.5 diopters in the right and left eye, respectively, with steep corneas on keratometry and a shallow anterior chamber depth. She underwent clear lens extraction with implantation of +35.0 D and +40.0 D IOL in the right eye and left eye, respectively. Her post-operative best-corrected visual acuity was 20/30 with +8.5 D in the right eye and +6 D in the left. She underwent bilateral ICL implantation. Postoperatively after 6 months, her unaided visual acuity was 20/30 in both eyes. In conclusion, ICL implantation can be considered to correct residual hypermetropic ametropia in pseudophakic eyes when other options have limitations.

  2. Gridded ionization chamber

    International Nuclear Information System (INIS)

    Houston, J.M.

    1977-01-01

    An improved ionization chamber type x-ray detector comprises a heavy gas at high pressure disposed between an anode and a cathode. An open grid structure is disposed adjacent the anode and is maintained at a voltsge intermediate between the cathode and anode potentials. The electric field which is produced by positive ions drifting toward the cathode is thus shielded from the anode. Current measuring circuits connected to the anode are, therefore, responsive only to electron current flow within the chamber and the recovery time of the chamber is shortened. The grid structure also serves to shield the anode from electrical currents which might otherwise be induced by mechanical vibrations in the ionization chamber structure

  3. Endovascular Management of Central Retinal Arterial Occlusion.

    Science.gov (United States)

    Agarwal, Nitin; Gala, Nihar B; Baumrind, Benjamin; Hansberry, David R; Thabet, Ahmad M; Gandhi, Chirag D; Prestigiacomo, Charles J

    2016-11-01

    Central retinal artery occlusion (CRAO) is an ophthalmologic emergency due to the sudden cessation of circulation to the inner retinal layer. Without immediate treatment, permanent blindness may ensue. Several treatment options exist, ranging from noninvasive medical management to thrombolysis. Nonetheless, ongoing debate exists regarding the best therapeutic strategy. The authors present the case of a 78-year-old woman with a medical history of hypercholesterolemia and rheumatoid arthritis who experienced complete loss of vision in her left eye. Following ophthalmologic evaluation demonstrating left CRAO, anterior chamber paracentesis was performed. Endovascular intervention was performed via local intra-arterial fibrinolysis with alteplase. Her vision returned to 20/20 following the procedure. In general, conventional therapies have not significantly improved patient outcomes. Several management options exist for CRAO. In general, conservative measures have not been reported to yield better patient outcomes as compared to the natural history of this medical emergency. Endovascular approaches are another option as observed with this case reported. In cases of CRAO, therapeutic strategies such as intra-arterial fibrinolysis utilize a local infusion of reactive tissue plasminogen activator directly at the site of occlusion via catheterization of the ophthalmic artery. Although several case series do show promising results after treating CRAO with intra-arterial fibrinolysis, further studies are required given the reports of complications.

  4. Clinical analysis of modified trabeculectomy in glaucoma surgery with high elevated intraocular pressure

    Directory of Open Access Journals (Sweden)

    Cang-Xia Zhang

    2013-10-01

    Full Text Available AIM: To make a retrospective analysis of the clinical data of modified trabeculectomy in treating glaucoma surgery with high elevated intraocular pressure retrospectively and evaluate the effect of modified trabeculectomy.METHODS:One hundred acute angle-closure glaucoma patients(100 eyeswith persistent high intraocular pressure were divided into treatment group(45 eyesand control group(55 eyes. Patients in treatment group was treated with by trabeculectomy, while those in control group received modified trabeculectomy. The modified measures include stellate ganglion block preoperative, topical anesthesia and local anesthesia with 20g/L lidocaine cotton-piece, to make scleral flap with sclerotome, to release aqueous humor outflow slowly after paracentesis of anterior chamber, and using mydriatic and cycloplegic during and after surgery.RESULTS: The incidence of operation complicationin control group was lower than that in treatment group. The differences were statistically significant(Pt=9.1535, Pt=39.8010, Pt=11.3219, PCONCLUSION: The modified trabeculectomy applied in the treatment of glaucoma with persistent high intraocular pressure can not only save the visual function of connection part to a certain extent, but also reduce the incidence of serious complications. It can obtain better intraocular pressure, shorten the average hospitalization days, decrease the expenses and increase patients satisfaction.

  5. [New etiological concepts in uveitis].

    Science.gov (United States)

    Bodaghi, B

    2005-05-01

    Uveitis remains an important cause of visual impairment, particularly in young patients. Idiopathic forms of intraocular inflammation should no longer be regarded as a presumed clinical entity, and the ophthalmologist must reconsider the specific etiology of primary uveitis when the clinical examination does not yield a definitive diagnosis or when the course of the disease on corticosteroids remains atypical. Laboratory tests based on serum analysis have limited value and should not be considered as diagnostic proof in different clinical presentations. The diagnostic management of infectious uveitis has been greatly improved by the use of molecular techniques applied to ocular fluids and tissues. Polymerase chain reaction (PCR) technology is a powerful tool that should be proposed in atypical cases of uveitis or retinitis of unclear but potentially infectious origin. This strategy is a major step before using unconventional and new immunomodulatory agents such as anti-TNF-alpha molecules. Under strict experimental conditions including adequate testing to rule out a possible contamination, PCR and its variants have changed our practical approach to intraocular inflammatory disorders and have provided new details for the understanding of infectious uveitis. The concept of pathogen-induced intraocular inflammation can be revisited in the light of molecular data obtained after anterior chamber paracentesis or diagnostic vitrectomy.

  6. Electromagnetic reverberation chambers

    CERN Document Server

    Besnier, Philippe

    2013-01-01

    Dedicated to a complete presentation on all aspects of reverberation chambers, this book provides the physical principles behind these test systems in a very progressive manner. The detailed panorama of parameters governing the operation of electromagnetic reverberation chambers details various applications such as radiated immunity, emissivity, and shielding efficiency experiments.In addition, the reader is provided with the elements of electromagnetic theory and statistics required to take full advantage of the basic operational rules of reverberation chambers, including calibration proc

  7. Dorsal skinfold chamber models in mice

    Directory of Open Access Journals (Sweden)

    Schreiter, Jeannine

    2017-07-01

    Full Text Available Background/purpose: The use of dorsal skinfold chamber models has substantially improved the understanding of micro-vascularisation in pathophysiology over the last eight decades. It allows pathophysiological studies of vascularisation over a continuous period of time. The dorsal skinfold chamber is an attractive technique for monitoring the vascularisation of autologous or allogenic transplants, wound healing, tumorigenesis and compatibility of biomaterial implants. To further reduce the animals’ discomfort while carrying the dorsal skinfold chamber, we developed a smaller chamber (the Leipzig Dorsal Skinfold Chamber and summarized the commercial available chamber models. In addition we compared our model to the common chamber. Methods: The Leipzig Dorsal Skinfold Chamber was applied to female mice with a mean weight of 22 g. Angiogenesis within the dorsal skinfold chamber was evaluated after injection of fluorescein isothiocyanate dextran with an Axio Scope microscope. The mean vessel density within the dorsal skinfold chamber was assessed over a period of 21 days at five different time points. The gained data were compared to previous results using a bigger and heavier dorsal skinfold model in mice. A PubMed and a patent search were performed and all papers related to “dorsal skinfold chamber” from 1 of January 2006 to 31 of December 2015 were evaluated regarding the dorsal skinfold chamber models and their technical improvements. The main models are described and compared to our titanium Leipzig Dorsal Skinfold Chamber model.Results: The Leipzig Dorsal Skinfold Chamber fulfils all requirements of continuous models known from previous chamber models while reducing irritation to the mice. Five different chamber models have been identified showing substantial regional diversity. The newly elaborated titanium dorsal skinfold chamber may replace the pre-existing titanium chamber model used in Germany so far, as it is smaller and lighter

  8. A combination drift chamber/pad chamber for very high readout rates

    International Nuclear Information System (INIS)

    Spiegel, L.; Cataldi, G.; Elia, V.; Mazur, P.; Murphy, C.T.; Smith, R.P.; Yang, W.; Alexopoulos, T.; Durandet, C.; Erwin, A.; Jennings, J.; Antoniazzi, L.; Introzzi, G.; Lanza, A.; Liguori, G.; Torre, P.; Arenton, M.; Conetti, S.; Cox, B.; Dukes, E.; Golovatyuk, V.; Hanlet, P.; McManus, A.; Nelson, K.; Recagni, M.; Segal, J.; Sun, J.; Ballagh, C.; Bingham, H.; Kaeding, T.; Lys, J.; Misawa, S.; Blankman, A.; Borodin, S.; Kononenko, W.; Newcomer, M.; Selove, W.; Trojak, T.; VanBerg, R.; Zhang, S.N.; Block, M.; Corti, G.; LeCompte, T.; Rosen, J.; Yao, T.; Boden, A.; Cline, D.; Ramachandran, S.; Rhoades, J.; Tokar, S.; Budagov, J.; Tsyganov, E.; Cao, Z.L.; He, M.; Wang, C.; Wei, C.; Zhang, N.; Chen, T.Y.; Yao, N.; Clark, K.; Jenkins, M.; Cooper, M.; Creti, P.; Gorini, E.; Grancagnolo, F.; Panareo, M.; Fortney, L.; Kowald, W.; Haire, M.; Judd, D.; Turnbull, L.; Wagoner, D.; Lau, K.; Mo, G.; Trischuk, J.

    1991-11-01

    Six medium-sized (∼1 x 2 m 2 ) drift chambers with pad and stripe readout have been constructed for and are presently operating in Fermi National Accelerator Laboratory experiment E-771. Each chamber module actually represents a pair of identical planes: two sets of anode wires, two sets of stripes, and two sets of pads. The wire planes are read out separately and represent X measurements in the coordinate system of the experiment. The twin stripe and pad planes are internally paired within the chamber modules; stripe signals represent Y measurements and pad signals combination X and Y measurements. Signals which develop on the stripes and pads are mirror (but inverted) images of what is seen on the wires. In addition to being used in the off-line pattern recognition, pad signals are also used as inputs to an on-line high transverse momentum (pt) trigger processor. While the techniques involved in the design and construction of the chambers are not novel, they may be of interest to experiments contemplating very large area, high rate chambers for future spectrometers

  9. A combination drift chamber/pad chamber for very high readout rates

    Energy Technology Data Exchange (ETDEWEB)

    Spiegel, L.; Cataldi, G.; Elia, V.; Mazur, P.; Murphy, C.T.; Smith, R.P.; Yang, W. (Fermi National Accelerator Lab., Batavia, IL (United States)); Alexopoulos, T.; Durandet, C.; Erwin, A.; Jennings, J. (Wisconsin Univ., Madison, WI (United States)); Antoniazzi, L.; Introzzi, G.; Lanza, A.; Liguori, G.; Torre, P. (Pavia Univ. (Italy) Istituto Nazionale di Fisica Nucleare, Rome (Italy)); Arenton, M.; Conetti, S.

    1991-11-01

    Six medium-sized ({approx}1 {times} 2 m{sup 2}) drift chambers with pad and stripe readout have been constructed for and are presently operating in Fermi National Accelerator Laboratory experiment E-771. Each chamber module actually represents a pair of identical planes: two sets of anode wires, two sets of stripes, and two sets of pads. The wire planes are read out separately and represent X measurements in the coordinate system of the experiment. The twin stripe and pad planes are internally paired within the chamber modules; stripe signals represent Y measurements and pad signals combination X and Y measurements. Signals which develop on the stripes and pads are mirror (but inverted) images of what is seen on the wires. In addition to being used in the off-line pattern recognition, pad signals are also used as inputs to an on-line high transverse momentum (pt) trigger processor. While the techniques involved in the design and construction of the chambers are not novel, they may be of interest to experiments contemplating very large area, high rate chambers for future spectrometers.

  10. Review of wire chamber aging

    International Nuclear Information System (INIS)

    Va'Vra, J.

    1986-02-01

    This paper makes an overview of the wire chamber aging problems as a function of various chamber design parameters. It emphasizes the chemistry point of view and many examples are drawn from the plasma chemistry field as a guidance for a possible effort in the wire chamber field. The paper emphasizes the necessity of variable tuning, the importance of purity of the wire chamber environment, as well as it provides a practical list of presently known recommendations. In addition, several models of the wire chamber aging are qualitatively discussed. The paper is based on a summary talk given at the Wire Chamber Aging Workshop held at LBL, Berkeley on January 16-17, 1986. Presented also at Wire Chamber Conference, Vienna, February 25-28, 1986. 74 refs., 18 figs., 11 tabs

  11. Anterior tibial stress fractures treated with anterior tension band plating in high-performance athletes.

    Science.gov (United States)

    Cruz, Alexandre Santa; de Hollanda, João Paris Buarque; Duarte, Aires; Hungria Neto, José Soares

    2013-06-01

    The non-surgical treatment of anterior tibial cortex stress fractures requires long periods of abstention from sports activities and often results in non-union. Many different surgical techniques have already been previously described to treat these fractures, but there is no consensus on the best treatment. We describe the outcome of treatment using anterior tibial tension band plating in three high-performance athletes (4 legs) with anterior tibial cortex stress fractures. Tibial osteosynthesis with a 3.5-mm locking compression plate in the anterolateral aspect of the tibia was performed in all patients diagnosed with anterior tibial stress fracture after September 2010 at Santa Casa Hospital. All of the fractures were consolidated within a period of 3 months after surgery, allowing for an early return to pre-injury levels of competitive sports activity. There were no infection, non-union, malunion or anterior knee pain complications. Anterior tibial tension band plating leads to prompt fracture consolidation and is a good alternative for the treatment of anterior tibial cortex stress fractures. Bone grafts were shown to be unnecessary.

  12. Anterior ankle arthroscopy, distraction or dorsiflexion?

    Science.gov (United States)

    de Leeuw, Peter A J; Golanó, Pau; Clavero, Joan A; van Dijk, C Niek

    2010-05-01

    Anterior ankle arthroscopy can basically be performed by two different methods; the dorsiflexion- or distraction method. The objective of this study was to determine the size of the anterior working area for both the dorsiflexion and distraction method. The anterior working area is anteriorly limited by the overlying anatomy which includes the neurovascular bundle. We hypothesize that in ankle dorsiflexion the anterior neurovascular bundle will move away anteriorly from the ankle joint, whereas in ankle distraction the anterior neurovascular bundle is pulled tight towards the joint, thereby decreasing the safe anterior working area. Six fresh frozen ankle specimens, amputated above the knee, were scanned with computed tomography. Prior to scanning the anterior tibial artery was injected with contrast fluid and subsequently each ankle was scanned both in ankle dorsiflexion and in distraction. A special device was developed to reproducibly obtain ankle dorsiflexion and distraction in the computed tomography scanner. The distance between the anterior border of the inferior tibial articular facet and the posterior border of the anterior tibial artery was measured. The median distance from the anterior border of the inferior tibial articular facet to the posterior border of the anterior tibial artery in ankle dorsiflexion and distraction was 0.9 cm (range 0.7-1.5) and 0.7 cm (range 0.5-0.8), respectively. The distance in ankle dorsiflexion significantly exceeded the distance in ankle distraction (P = 0.03). The current study shows a significantly increased distance between the anterior distal tibia and the overlying anterior neurovascular bundle with the ankle in a slightly dorsiflexed position as compared to the distracted ankle position. We thereby conclude that the distracted ankle position puts the neurovascular structures more at risk for iatrogenic damage when performing anterior ankle arthroscopy.

  13. Change of Pressing Chamber Conicalness at Briquetting Process in Briquetting Machine Pressing Chamber

    Directory of Open Access Journals (Sweden)

    Peter Križan

    2012-01-01

    Full Text Available In this paper, we will present the impact of the conical shape of a pressing chamber, an important structural parameter. Besides the known impact of the technological parameters of pressing chambers, it is also very important to pay attention to their structural parameters. In the introduction, we present a theoretical analysis of pressing chamber conicalness. An experiment aimed at detecting this impact was performed at our institute, and it showed that increasing the conicalness of a pressing chamber improves the quality of the final briquettes. The conicalness of the pressing chamber has a significanteffect on the final briquette quality and on the construction of briquetting machines. The experimental findings presented here show the importance of this parameter in the briquetting process.

  14. Anterior ankle arthroscopy, distraction or dorsiflexion?

    OpenAIRE

    de Leeuw, P.A.J.; Golanó, P.; Clavero, J.A.; van Dijk, C.N.

    2010-01-01

    Anterior ankle arthroscopy can basically be performed by two different methods; the dorsiflexion- or distraction method. The objective of this study was to determine the size of the anterior working area for both the dorsiflexion and distraction method. The anterior working area is anteriorly limited by the overlying anatomy which includes the neurovascular bundle. We hypothesize that in ankle dorsiflexion the anterior neurovascular bundle will move away anteriorly from the ankle joint, where...

  15. Sleeve reaction chamber system

    Science.gov (United States)

    Northrup, M Allen [Berkeley, CA; Beeman, Barton V [San Mateo, CA; Benett, William J [Livermore, CA; Hadley, Dean R [Manteca, CA; Landre, Phoebe [Livermore, CA; Lehew, Stacy L [Livermore, CA; Krulevitch, Peter A [Pleasanton, CA

    2009-08-25

    A chemical reaction chamber system that combines devices such as doped polysilicon for heating, bulk silicon for convective cooling, and thermoelectric (TE) coolers to augment the heating and cooling rates of the reaction chamber or chambers. In addition the system includes non-silicon-based reaction chambers such as any high thermal conductivity material used in combination with a thermoelectric cooling mechanism (i.e., Peltier device). The heat contained in the thermally conductive part of the system can be used/reused to heat the device, thereby conserving energy and expediting the heating/cooling rates. The system combines a micromachined silicon reaction chamber, for example, with an additional module/device for augmented heating/cooling using the Peltier effect. This additional module is particularly useful in extreme environments (very hot or extremely cold) where augmented heating/cooling would be useful to speed up the thermal cycling rates. The chemical reaction chamber system has various applications for synthesis or processing of organic, inorganic, or biochemical reactions, including the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction.

  16. Dual-chamber inflatable oil boom

    International Nuclear Information System (INIS)

    Blair, R.M.; Tedeschi, E.T.

    1993-01-01

    An elongated floating material containment boom section is described having a normally vertical ballasted skirt depending from flotation means, and convertible from a flattened collapsed condition to a deployable condition wherein buoyancy chamber means extending along the upper edge of said skirt are inflated to expanded buoyant configuration, including: a gas-impervious sleeve extending along the upper edge of said normally vertical skirt forming a first outer collapsible and inflatable flotation chamber, a first inflation valve connecting the interior of said sleeve with the ambient atmosphere, through which gas under pressure may be introduced into said sleeve to inflate said first buoyant outer flotation chamber, elongated gas-impervious tube means positioned inside said outer flotation chamber and forming second collapsible and inflatable internal flotation bladder chamber means, second inflation valve means connecting the interior of said bladder means through said outer flotation chamber to the ambient atmosphere through which gas under pressure may be introduced into said bladder means to inflate it forming said second flotation chamber means inside said outer flotation chamber

  17. BEBC bubble chamber

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    Looking up into the interior of BEBC bubble chamber from the expansion cylinder. At the top of the chamber two fish-eye lenses are installed and three other fish-eye ports are blanked off. In the centre is a heat exchanger.

  18. Climatic chamber ergometer

    CSIR Research Space (South Africa)

    Atkins, AR

    1968-01-01

    Full Text Available The design and calibration of an ergometer for exercising subjects during calorimetric studies in the climate chamber, are described. The ergometer is built into the climatic chamber and forms an integral part of the whole instrumentation system foe...

  19. Vacuum Chambers for LEP sections

    CERN Multimedia

    1983-01-01

    The picture shows sections of the LEP vacuum chambers to be installed in the dipole magnets (left) and in the quadrupoles (right). The dipole chamber has three channels: the beam chamber, the pumping duct where the NEG (non-evaporabe getter) is installed and the water channel for cooling (on top in the picture). The pumping duct is connected to the beam chamber through holes in the separating wall. The thick lead lining to shield radiation can also be seen. These chambers were manufactured as extruded aluminium alloy profiles.

  20. Reference ionization chamber

    International Nuclear Information System (INIS)

    Golnik, N.; Zielczynski, M.

    1999-01-01

    The paper presents the design of ionization chamber devoted for the determination of the absolute value of the absorbed dose in tissue-equivalent material. The special attention was paid to ensure that the volume of the active gas cavity was constant and well known. A specific property of the chamber design is that the voltage insulators are 'invisible' from any point of the active volume. Such configuration ensures a very good time stability of the electrical field and defines the active volume. The active volume of the chamber was determined with accuracy of 0.3%. This resulted in accuracy of 0.8% in determination of the absorbed dose in the layer of material adherent to the gas cavity. The chamber was applied for calibration purposes at radiotherapy facility in Joint Institute for Nuclear Research in Dubna (Russia) and in the calibration laboratory of the Institute of Atomic Energy in Swierk. (author)

  1. Plastic flashtube chambers

    International Nuclear Information System (INIS)

    Frisken, W.R.

    1977-01-01

    A brief discussion is given of the use and operation of plastic flashtube chambers. Gas leaks, electric pulsing, the glow discharge, and readout methods are considered. Three distinct problems with high rate applications deal with resolving time, dead time, and polarization/neutralization of the chamber

  2. Wire chambers: Trends and alternatives

    Energy Technology Data Exchange (ETDEWEB)

    Regler, Meinhard

    1992-05-15

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!.

  3. Prototype multiwire proportional chamber

    CERN Multimedia

    1975-01-01

    Chambers of this type were initially developed within the Alpha project (finally not approved). They were designed such to minimize the radiation length with a view to a mass spectrometer of high resolution meant to replace the Omega detector. The chambers were clearly forerunners for the (drift) chambers later built for R606 with the novel technique of crimping the wires. See also photo 7510039X.

  4. Miniature ionization chamber

    International Nuclear Information System (INIS)

    Alexeev, V.I.; Emelyanov, I.Y.; Ivanov, V.M.; Konstantinov, L.V.; Lysikov, B.V.; Postnikov, V.V.; Rybakov, J.V.

    1976-01-01

    A miniature ionization chamber having a gas-filled housing which accommodates a guard electrode made in the form of a hollow perforated cylinder is described. The cylinder is electrically associated with the intermediate coaxial conductor of a triaxial cable used as the lead-in of the ionization chamber. The gas-filled housing of the ionization chamber also accommodates a collecting electrode shaped as a rod electrically connected to the center conductor of the cable and to tubular members. The rod is disposed internally of the guard electrode and is electrically connected, by means of jumpers passing through the holes in the guard electrode, to the tubular members. The tubular members embrace the guard electrode and are spaced a certain distance apart along its entire length. Arranged intermediate of these tubular members are spacers secured to the guard electrode and fixing the collecting electrode throughout its length with respect to the housing of the ionization chamber

  5. Wire chambers: Trends and alternatives

    International Nuclear Information System (INIS)

    Regler, Meinhard

    1992-01-01

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!

  6. A new plant chamber facility PLUS coupled to the atmospheric simulation chamber SAPHIR

    Science.gov (United States)

    Hohaus, T.; Kuhn, U.; Andres, S.; Kaminski, M.; Rohrer, F.; Tillmann, R.; Wahner, A.; Wegener, R.; Yu, Z.; Kiendler-Scharr, A.

    2015-11-01

    A new PLant chamber Unit for Simulation (PLUS) for use with the atmosphere simulation chamber SAPHIR (Simulation of Atmospheric PHotochemistry In a large Reaction Chamber) has been build and characterized at the Forschungszentrum Jülich GmbH, Germany. The PLUS chamber is an environmentally controlled flow through plant chamber. Inside PLUS the natural blend of biogenic emissions of trees are mixed with synthetic air and are transferred to the SAPHIR chamber where the atmospheric chemistry and the impact of biogenic volatile organic compounds (BVOC) can be studied in detail. In PLUS all important enviromental parameters (e.g. temperature, PAR, soil RH etc.) are well-controlled. The gas exchange volume of 9.32 m3 which encloses the stem and the leafes of the plants is constructed such that gases are exposed to FEP Teflon film and other Teflon surfaces only to minimize any potential losses of BVOCs in the chamber. Solar radiation is simulated using 15 LED panels which have an emission strength up to 800 μmol m-2 s-1. Results of the initial characterization experiments are presented in detail. Background concentrations, mixing inside the gas exchange volume, and transfer rate of volatile organic compounds (VOC) through PLUS under different humidity conditions are explored. Typical plant characteristics such as light and temperature dependent BVOC emissions are studied using six Quercus Ilex trees and compared to previous studies. Results of an initial ozonolysis experiment of BVOC emissions from Quercus Ilex at typical atmospheric concentrations inside SAPHIR are presented to demonstrate a typical experimental set up and the utility of the newly added plant chamber.

  7. A new plant chamber facility, PLUS, coupled to the atmosphere simulation chamber SAPHIR

    Science.gov (United States)

    Hohaus, T.; Kuhn, U.; Andres, S.; Kaminski, M.; Rohrer, F.; Tillmann, R.; Wahner, A.; Wegener, R.; Yu, Z.; Kiendler-Scharr, A.

    2016-03-01

    A new PLant chamber Unit for Simulation (PLUS) for use with the atmosphere simulation chamber SAPHIR (Simulation of Atmospheric PHotochemistry In a large Reaction Chamber) has been built and characterized at the Forschungszentrum Jülich GmbH, Germany. The PLUS chamber is an environmentally controlled flow-through plant chamber. Inside PLUS the natural blend of biogenic emissions of trees is mixed with synthetic air and transferred to the SAPHIR chamber, where the atmospheric chemistry and the impact of biogenic volatile organic compounds (BVOCs) can be studied in detail. In PLUS all important environmental parameters (e.g., temperature, photosynthetically active radiation (PAR), soil relative humidity (RH)) are well controlled. The gas exchange volume of 9.32 m3 which encloses the stem and the leaves of the plants is constructed such that gases are exposed to only fluorinated ethylene propylene (FEP) Teflon film and other Teflon surfaces to minimize any potential losses of BVOCs in the chamber. Solar radiation is simulated using 15 light-emitting diode (LED) panels, which have an emission strength up to 800 µmol m-2 s-1. Results of the initial characterization experiments are presented in detail. Background concentrations, mixing inside the gas exchange volume, and transfer rate of volatile organic compounds (VOCs) through PLUS under different humidity conditions are explored. Typical plant characteristics such as light- and temperature- dependent BVOC emissions are studied using six Quercus ilex trees and compared to previous studies. Results of an initial ozonolysis experiment of BVOC emissions from Quercus ilex at typical atmospheric concentrations inside SAPHIR are presented to demonstrate a typical experimental setup and the utility of the newly added plant chamber.

  8. Anterior ankle arthroscopy, distraction or dorsiflexion?

    NARCIS (Netherlands)

    de Leeuw, P.A.J.; Golanó, P.; Clavero, J.A.; van Dijk, C.N.

    2010-01-01

    Anterior ankle arthroscopy can basically be performed by two different methods; the dorsiflexion- or distraction method. The objective of this study was to determine the size of the anterior working area for both the dorsiflexion and distraction method. The anterior working area is anteriorly

  9. Directed Energy Anechoic Chamber

    Data.gov (United States)

    Federal Laboratory Consortium — The Directed Energy Anechoic Chamber comprises a power anechoic chamber and one transverse electromagnetic cell for characterizing radiofrequency (RF) responses of...

  10. Streamer chamber: pion decay

    CERN Multimedia

    1992-01-01

    The real particles produced in the decay of a positive pion can be seen in this image from a streamer chamber. Streamer chambers consist of a gas chamber through which a strong pulsed electric field is passed, creating sparks as a charged particle passes through it. A magnetic field is added to cause the decay products to follow curved paths so that their charge and momentum can be measured.

  11. PS wire chamber

    CERN Multimedia

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  12. Directional muon jet chamber for a muon collider (Groovy Chamber)

    International Nuclear Information System (INIS)

    Atac, M.

    1996-10-01

    A directional jet drift chamber with PAD readout is proposed here which can select vertex originated muons within a given time window and eliminate those muons which primarily originate upstream, using only a PAD readout. Drift time provides the Z-coordinate, and the center of gravity of charge distribution provides the r-ψ coordinates. Directionality at the trigger level is obtained by the timing measurement from the PAD hits within a given time window. Because of the long drift time between the bunch crossings, a muon collider enables one to choose a drift distance in the drift chamber as long as 50 cm. This is an important factor in reducing cost of drift chambers which have to cover relatively large areas

  13. Pencil-shaped radiation detection ionization chamber

    International Nuclear Information System (INIS)

    Suzuki, A.

    1979-01-01

    A radiation detection ionization chamber is described. It consists of an elongated cylindrical pencil-shaped tubing forming an outer wall of the chamber and a center electrode disposed along the major axis of the tubing. The length of the chamber is substantially greater than the diameter. A cable connecting portion at one end of the chamber is provided for connecting the chamber to a triaxial cable. An end support portion is connected at the other end of the chamber for supporting and tensioning the center electrode. 17 claims

  14. Improvement of Swirl Chamber Structure of Swirl-Chamber Diesel Engine Based on Flow Field Characteristics

    Directory of Open Access Journals (Sweden)

    Wenhua Yuan

    2014-10-01

    Full Text Available In order to improve combustion characteristic of swirl chamber diesel engine, a simulation model about a traditional cylindrical flat-bottom swirl chamber turbulent combustion diesel engine was established within the timeframe of the piston motion from the bottom dead centre (BDC to the top dead centre (TDC with the fluent dynamic mesh technique and flow field vector of gas in swirl chamber and cylinder; the pressure variation and temperature variation were obtained and a new type of swirl chamber structure was proposed. The results reveal that the piston will move from BDC; air in the cylinder is compressed into the swirl chamber by the piston to develop a swirl inside the chamber, with the ongoing of compression; the pressure and temperature are also rising gradually. Under this condition, the demand of diesel oil mixing and combusting will be better satisfied. Moreover, the new structure will no longer forma small fluid retention zone at the lower end outside the chamber and will be more beneficial to the mixing of fuel oil and air, which has presented a new idea and theoretical foundation for the design and optimization of swirl chamber structure and is thus of good significance of guiding in this regard.

  15. Establishment of a radon test chamber

    International Nuclear Information System (INIS)

    Chen Chingjiang; Liu Chichang; Lin Yuming

    1993-01-01

    A walk-in type radon test chamber of 23 m 3 has been built for testing and calibration of radon measurement instruments. The environmental conditions of the test chamber can be varied within a wide range of values. The design objectives specification, monitoring instruments and testing results of this chamber are discussed. This test chamber is available for domestic radon researchers and its accuracy can be traced to the international standard. A routine intercomparison study will be held annually by using this chamber. Other tests like radon progeny and thoron standard may also be performed in this chamber. (1 fig.)

  16. Wolbachia utilizes host microtubules and Dynein for anterior localization in the Drosophila oocyte.

    Directory of Open Access Journals (Sweden)

    Patrick M Ferree

    2005-10-01

    Full Text Available To investigate the role of the host cytoskeleton in the maternal transmission of the endoparasitic bacteria Wolbachia, we have characterized their distribution in the female germ line of Drosophila melanogaster. In the germarium, Wolbachia are distributed to all germ cells of the cyst, establishing an early infection in the cell destined to become the oocyte. During mid-oogenesis, Wolbachia exhibit a distinct concentration between the anterior cortex and the nucleus in the oocyte, where many bacteria appear to contact the nuclear envelope. Following programmed rearrangement of the microtubule network, Wolbachia dissociate from this anterior position and become dispersed throughout the oocyte. This localization pattern is distinct from mitochondria and all known axis determinants. Manipulation of microtubules and cytoplasmic Dynein and Dynactin, but not Kinesin-1, disrupts anterior bacterial localization in the oocyte. In live egg chambers, Wolbachia exhibit movement in nurse cells but not in the oocyte, suggesting that the bacteria are anchored by host factors. In addition, we identify mid-oogenesis as a period in the life cycle of Wolbachia in which bacterial replication occurs. Total bacterial counts show that Wolbachia increase at a significantly higher rate in the oocyte than in the average nurse cell, and that normal Wolbachia levels in the oocyte depend on microtubules. These findings demonstrate that Wolbachia utilize the host microtubule network and associated proteins for their subcellular localization in the Drosophila oocyte. These interactions may also play a role in bacterial motility and replication, ultimately leading to the bacteria's efficient maternal transmission.

  17. National Ignition Facility Target Chamber

    International Nuclear Information System (INIS)

    Wavrik, R W; Cox, J R; Fleming, P J

    2000-01-01

    On June 11, 1999 the Department of Energy dedicated the single largest piece of the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) in Livermore, California. The ten (10) meter diameter aluminum target high vacuum chamber will serve as the working end of the largest laser in the world. The output of 192 laser beams will converge at the precise center of the chamber. The laser beams will enter the chamber in two by two arrays to illuminate 10 millimeter long gold cylinders called hohlraums enclosing 2 millimeter capsule containing deuterium, tritium and isotopes of hydrogen. The two isotopes will fuse, thereby creating temperatures and pressures resembling those found only inside stars and in detonated nuclear weapons, but on a minute scale. The NIF Project will serve as an essential facility to insure safety and reliability of our nation's nuclear arsenal as well as demonstrating inertial fusion's contribution to creating electrical power. The paper will discuss the requirements that had to be addressed during the design, fabrication and testing of the target chamber. A team from Sandia National Laboratories (SNL) and LLNL with input from industry performed the configuration and basic design of the target chamber. The method of fabrication and construction of the aluminum target chamber was devised by Pitt-Des Moines, Inc. (PDM). PDM also participated in the design of the chamber in areas such as the Target Chamber Realignment and Adjustment System, which would allow realignment of the sphere laser beams in the event of earth settlement or movement from a seismic event. During the fabrication of the target chamber the sphericity tolerances had to be addressed for the individual plates. Procedures were developed for forming, edge preparation and welding of individual plates. Construction plans were developed to allow the field construction of the target chamber to occur parallel to other NIF construction activities. This was

  18. Impact of Indocyanine Green Concentration, Exposure Time, and Degree of Dissolution in Creating Toxic Anterior Segment Syndrome: Evaluation in a Rabbit Model

    Directory of Open Access Journals (Sweden)

    Tamer Tandogan

    2016-01-01

    Full Text Available Purpose. To investigate the role of indocyanine green (ICG dye as a causative material of toxic anterior segment syndrome (TASS in an experimental rabbit model. Method. Eight eyes of four rabbits were allocated to this study. Capsular staining was performed using ICG dye, after which the anterior chamber was irrigated with a balanced salt solution. The effects of different concentrations (control, 0.25, 0.5, and 1.0%, exposure times (10 and 60 seconds, and the degree of dissolution (differently vortexed were investigated. The analysis involved anterior segment photography, ultrasound pachymetry, prostaglandin assay (PGE2 Parameter Assay, R&D systems, Inc., and scanning electron microscopy of each iris. Result. There was no reaction in the control eye. A higher aqueous level of PGE2 and more severe inflammatory reaction were observed in cases of eyes with higher concentration, longer exposure time, and poorly dissolved dye. Additionally, scanning electron microscopy revealed larger and coarser ICG particles. Conclusion. TASS occurrence may be associated with the concentration, exposure time, and degree of dissolution of ICG dye during cataract surgery.

  19. Tratamiento de la mordida cruzada anterior con plano inclinado anterior. Efecto sobre los arcos dentales

    OpenAIRE

    Carolina Rodríguez Manjarrés; Jesús Alberto Hernández Silva

    2017-01-01

    Objetivo: Evaluar los cambios dimensionales de los arcos dentales primarios tratados con plano inclinado anterior como método de corrección de la mordida cruzada anterior. Métodos: Se trataron 10 pacientes con edades entre 3 y 5 años afectados con mordida cruzada anterior completa, se colocó un plano inclinado anterior elaborado en acrílico, que estuvo en posición en promedio 8.5 semanas. Se obtuvieron modelos de estudio en 3 momentos T0: antes del tratamiento; T1: 6 meses después de iniciado...

  20. Cloud Chamber

    DEFF Research Database (Denmark)

    Gfader, Verina

    Cloud Chamber takes its roots in a performance project, titled The Guests 做东, devised by Verina Gfader for the 11th Shanghai Biennale, ‘Why Not Ask Again: Arguments, Counter-arguments, and Stories’. Departing from the inclusion of the biennale audience to write a future folk tale, Cloud Chamber......: fiction and translation and translation through time; post literacy; world picturing-world typing; and cartographic entanglements and expressions of subjectivity; through the lens a social imaginary of worlding or cosmological quest. Art at its core? Contributions by Nikos Papastergiadis, Rebecca Carson...

  1. Anterior segment dysgenesis associated with Williams-Beuren syndrome: a case report and review of the literature.

    Science.gov (United States)

    Todorova, Margarita G; Grieshaber, Matthias C; Cámara, Rafael J A; Miny, Peter; Palmowski-Wolfe, Anja M

    2014-05-21

    Williams-Beuren syndrome is characterized by mild mental retardation, specific neurocognitive profile, hypercalcemia during infancy, distinctive facial features and cardiovascular diseases. We report on complete ophthalmologic, sonographic and genetic evaluation of a girl with a clinical phenotype of Williams-Beuren syndrome, associated with unilateral anterior segment dysgenesis and bilateral cleft of the soft and hard palate. These phenotypic features have not been linked to the haploinsufficiency of genes involved in the microdeletion. A term born girl presented at the initial examination with clouding of the right cornea. On ultrasound biomicroscopy the anterior chamber structures were difficult to differentiate, showing severe adhesions from the opacified cornea to the iris with a kerato-irido-lenticular contact to the remnant lens, a finding consistent with Peters' anomaly. Genetic analyses including FISH confirmed a loss of the critical region 7q11.23, usually associated with the typical Williams-Beuren syndrome. Microsatellite analysis showed a loss of about 2.36 Mb. A diagnosis of Williams-Beuren syndrome was made based on the microdeletion of 7q11.23. The unique features, including unilateral microphthalmia and anterior segment dysgenesis, were unlikely to be caused by the microdeletion. Arguments in favor of the latter are unilateral manifestation, as well as the fact that numerous patients with deletions of comparable or microscopically visible size have not shown similar manifestations.

  2. Mild toxic anterior segment syndrome mimicking delayed onset toxic anterior segment syndrome after cataract surgery

    Directory of Open Access Journals (Sweden)

    Su-Na Lee

    2014-01-01

    Full Text Available Toxic anterior segment syndrome (TASS is an acute sterile postoperative anterior segment inflammation that may occur after anterior segment surgery. I report herein a case that developed mild TASS in one eye after bilateral uneventful cataract surgery, which was masked during early postoperative period under steroid eye drop and mimicking delayed onset TASS after switching to weaker steroid eye drop.

  3. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  4. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  5. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  6. Criteria for controlled atmosphere chambers

    International Nuclear Information System (INIS)

    Robinson, J.N.

    1980-03-01

    The criteria for design, construction, and operation of controlled atmosphere chambers intended for service at ORNL are presented. Classification of chambers, materials for construction, design criteria, design, controlled atmosphere chamber systems, and operating procedures are presented. ORNL Safety Manual Procedure 2.1; ORNL Health Physics Procedure Manual Appendix A-7; and Design of Viewing Windows are included in 3 appendices

  7. MRI appearances of the anterior fibulocalcaneus muscle: a rare anterior compartment muscle

    Energy Technology Data Exchange (ETDEWEB)

    Upadhyay, Bhavin [Basildon and Thurrock University Hospitals NHS Foundation Trust, Imaging Department, Essex (United Kingdom); Amiras, Dimitri [Imperial College Health Care NHS Trust, Imaging Department, London (United Kingdom)

    2015-05-01

    MRI of a 62-year-old female presenting with ankle pain demonstrated an accessory muscle within the anterior compartment of the lower leg. The muscle originated from the fibula and anterior crural septum. The tendon passed anterior to the lateral malleolus and inserted at the critical angle of Gissane on the calcaneus. This muscle was initially described in the anatomic literature by Lambert and Atsas in 2010. To our knowledge, this is the first time the MRI appearances of this muscle has been described in the radiological literature. Awareness of the fibulocalcaneal muscle is important as it may represent a cause of ankle pain. In addition, the tendon could potentially be harvested for use in reconstructive procedures. (orig.)

  8. Proceedings of workshop on streamer chamber

    International Nuclear Information System (INIS)

    Itoh, Hidihiko; Takahashi, Kaoru; Hirose, Tachishige; Masaike, Akira

    1978-08-01

    For high accuracy observation of multiple-body reactions, a vertex detector of high efficiency is essential. A bubble chamber, though excellent for tracks detection, is problematic in statistics accuracy. The vertex detector with a wire chamber, while better in this respect, difficult in multiple-particle detection etc. The workshop has had several meetings on a streamer chamber as a detector combining features of both bubble chamber and counter, with emphasis on tracks observation in avalanche mode and recordings not using films. Contents are on streamer chamber gas, analytical photography, data processing, simulation program, etc. (Mori, K.)

  9. Gridded Ionization Chamber

    International Nuclear Information System (INIS)

    Manero Amoros, F.

    1962-01-01

    In the present paper the working principles of a gridded ionization chamber are given, and all the different factors that determine its resolution power are analyzed in detail. One of these devices, built in the Physics Division of the JEN and designed specially for use in measurements of alpha spectroscopy, is described. finally the main applications, in which the chamber can be used, are shown. (Author) 17 refs

  10. Anterior approach for knee arthrography

    International Nuclear Information System (INIS)

    Zurlo, J.V.; Towers, J.D.; Golla, S.

    2001-01-01

    Objective. To develop a new method of magnetic resonance arthrography (MRA) of the knee using an anterior approach analogous to the portals used for knee arthroscopy.Design. An anterior approach to the knee joint was devised mimicking anterior portals used for knee arthroscopy. Seven patients scheduled for routine knee MRA were placed in a decubitus position and under fluoroscopic guidance a needle was advanced from a position adjacent to the patellar tendon into the knee joint. After confirmation of the needle tip location, a dilute gadolinium solution was injected.Results and conclusion. All the arthrograms were technically successful. The anterior approach to knee MRA has greater technical ease than the traditional approach with little patient discomfort. (orig.)

  11. The CLEO III drift chamber

    CERN Document Server

    Peterson, D; Briere, R A; Chen, G; Cronin-Hennessy, D; Csorna, S; Dickson, M; Dombrowski, S V; Ecklund, K M; Lyon, A; Marka, S; Meyer, T O; Patterson, J R; Sadoff, A; Thies, P; Thorndike, E H; Urner, D

    2002-01-01

    The CLEO group at the Cornell Electron Storage Ring has constructed and commissioned a new central drift chamber. With 9796 cells arranged in 47 layers ranging in radius from 13.2 to 79 cm, the new drift chamber has a smaller outer radius and fewer wires than the drift chamber it replaces, but allows the CLEO tracking system to have improved momentum resolution. Reduced scattering material in the chamber gas and in the inner skin separating the drift chamber from the silicon vertex detector provides a reduction of the multiple scattering component of the momentum resolution and an extension of the usable measurement length into the silicon. Momentum resolution is further improved through quality control in wire positioning and symmetry of the electric fields in the drift cells which have provided a reduction in the spatial resolution to 88 mu m (averaged over the full drift range).

  12. Capsulorhexis contraction after cataract surgery: Comparison of sharp anterior edge and modified anterior edge acrylic intraocular lenses

    DEFF Research Database (Denmark)

    Corydon, C.; Lindholt, M.; Knudsen, E.B.

    2007-01-01

    eyes) were included in a prospective randomized study. All had phacoemulsification followed by implantation of an IOL with a modified anterior edge (38 eyes) or a sharp anterior edge (46 eyes). One day (baseline) and 3 months postoperatively, the area of the anterior capsule opening was measured using...... retroillumination photographs. RESULTS: There was a significant reduction in the area of the anterior capsule opening from 1 day to 3 months postoperatively in both groups (Psharp...

  13. OPAL Jet Chamber Prototype

    CERN Multimedia

    OPAL was one of the four experiments installed at the LEP particle accelerator from 1989 - 2000. OPAL's central tracking system consists of (in order of increasing radius) a silicon microvertex detector, a vertex detector, a jet chamber, and z-chambers. All the tracking detectors work by observing the ionization of atoms by charged particles passing by: when the atoms are ionized, electrons are knocked out of their atomic orbitals, and are then able to move freely in the detector. These ionization electrons are detected in the dirfferent parts of the tracking system. This piece is a prototype of the jet chambers

  14. Absorbed dose measurement by using tissue equivalent ionization chamber (pair ionization chamber) in the Yayoi reactor

    International Nuclear Information System (INIS)

    Sasuga, N.; Okamura, K.; Terakado, T.; Mabuchi, Y.; Nakagawa, T.; Sukegawa, Toshio; Aizawa, C.; Saito, I.; Oka, Yoshiaki

    1998-01-01

    Each dose rate of neutron and gamma ray in the thermal column of the Yayoi reactor, in which an epithermal neutron field will be used for the boron neutron capture therapy, was measured by using a tissue equivalent ionization chamber and a graphite chamber. The tissue equivalent ionization chamber has some response to both neutron and gamma ray, but the graphite chamber has a few response to the neutron, so called pair ionization chamber method. The epithermal neutron fluxes of the thermal column were calculated by ANISN (one dimensional neutron-gamma transport code). A measured value for gamma dose rate by the pair ionization chamber agrees relevantly with a calculated result. For neutron dose rate, however, the measured value was too much small in comparison with the calculated result. The discrepancy between the measured value and the calculated result for neutron dose rate is discussed in detail in the report. (M. Suetake)

  15. Development of secondary chamber for tar cracking-improvement of wood pyrolysis performance in pre-vacuum chamber

    Science.gov (United States)

    Siahaan, S.; Homma, H.; Homma, H.

    2018-02-01

    Energy crisis and global warming, in other words, climate change are critical topics discussed in various parts of the world. Global warming primarily result from too much emission of carbon dioxide (CO2) in the atmosphere. To mitigate global warming, or climate change and improve electrification in rural areas, wood pyrolysis technology is developed in a laboratory scale, of which gases are directly applicable to the gas engine generator. Our laboratory has developed a prototype of wood pyrolysis plant with a pre-vacuum chamber. However, tar yield was around 40 wt% of feedstock. This research aims to reduce tar yield by secondary tar cracking. For the secondary tar cracking, a secondary pre-vacuum chamber is installed after primary pre-vacuum chamber. Gases generated in the primary pre-vacuum chamber are lead into the secondary chamber that is heated up to 1000 K. This paper reports performance of the secondary chamber for secondary tar cracking in homogeneous mode and heterogeneous mode with char.

  16. Predictors of Percutaneous Catheter Drainage (PCD) after Abdominal Paracentesis Drainage (APD) in Patients with Moderately Severe or Severe Acute Pancreatitis along with Fluid Collections

    Science.gov (United States)

    Liu, Wei-hui; Wang, Tao; Yan, Hong-tao; Chen, Tao; Xu, Chuan; Ye, Ping; Zhang, Ning; Liu, Zheng-cai; Tang, Li-jun

    2015-01-01

    Aims Although we previously demonstrated abdominal paracentesis drainage (APD) preceding percutaneous catheter drainage (PCD) as the central step for treating patients with moderately severe (MSAP) or severe acute pancreatitis (SAP), the predictors leading to PCD after APD have not been studied. Methods Consecutive patients with MSAP or SAP were recruited between June 2011 and June 2013. As a step-up approach, all patients initially received medical management, later underwent ultrasound-guided APD before PCD, if necessary, followed by endoscopic necrosectomy through the path formed by PCD. APD primarily targeted fluid in the abdominal or pelvic cavities, whereas PCD aimed at (peri)pancreatic fluid. Results Of the 92 enrolled patients, 40 were managed with APD alone and 52 received PCD after APD (14 required necrosectomy after initial PCD). The overall mortality was 6.5%. Univariate analysis showed that among the 20 selected parameters, 13 factors significantly affected PCD intervention after APD. Multivariate analysis revealed that infected (peri)pancreatic collections (P = -0.001), maximum extent of necrosis of more than 30% of the pancreas (P = -0.024), size of the largest necrotic peri(pancreatic) collection (P = -0.007), and reduction of (peri)pancreatic fluid collections by collections, a largest necrotic peri(pancreatic) collection of more than 100 ml, and reduction of (peri)pancreatic fluid collections by <50% after APD could effectively predict the need for PCD in the early course of the disease. PMID:25659143

  17. Anterior vitrectomy and partial capsulectomy via anterior approach to treat chronic postoperative endophthalmitis

    Directory of Open Access Journals (Sweden)

    Mete Güler

    2013-02-01

    Full Text Available AIM:To describe the results of vitrectomy and partial capsulectomy via anterior approach surgical technique in treatment of chronic postoperative endophthalmitis (CPE.METHODS:Clinical records of 9 patients treated for CPE between 2006 and 2010 were reviewed retrospectively. All of these patients were treated with vitrectomy and partial capsulectomy via anterior approach.RESULTS:Six of 9 patients were male. The average patients’ age was (60±8.1 years. The average period between cataract extraction and onset of signs and symptoms was (3.6±1.3 weeks. The average presenting visual acuity was 0.3±0.1 and the average final post operative visual acuity was 0.7±0.2. The mean follow-up period was (28.1±8.9 weeks. In all patients, the inflammation subsided after surgery.CONCLUSION:Our results suggest that anterior vitrectomy and partial capsulectomy via anterior approach may be considered as potentially useful and relatively less invasive technique to treat CPE.

  18. [Anterior guidance in complete dentures].

    Science.gov (United States)

    Dubreuil, J; Trevelo, A

    1990-01-01

    Although the anterior guidance in complete dentures is not really a guide, the arrangement of the anterior maxillary and mandibular prosthetic teeth, defines a propulsive line called the virtual anterior guidance, a part from the cinematic criterias. The influence of this guide on cuspal movement is superior, in all mandibular points, to the influence of the condylar pathway. If this line is not respected, the practitioner may have to do excessive grindings during occlusal adjustments.

  19. Immediate postoperative anterior knee stability: double- versus triple-bundle anterior cruciate ligament reconstructions.

    Science.gov (United States)

    Mae, Tatsuo; Shino, Konsei; Matsumoto, Norinao; Yoneda, Kenji; Yoshikawa, Hideki; Nakata, Ken

    2013-02-01

    The purpose of this study was to compare the triple-bundle (TB) anterior cruciate ligament (ACL) reconstruction with the double-bundle (DB) ACL reconstruction in immediate postoperative anterior knee stability. This study involved 133 patients who had undergone the anatomic ACL reconstruction with autogenous hamstring tendon unilaterally. Then 83 patients (mean age, 28.8 years) underwent the DB between November 2004 and December 2005, and 50 patients (mean age, 29.6 years) underwent the TB ACL reconstruction between January and December 2006. The 2 femoral tunnels were created in the ideal ACL attachment area, whereas 2 tibial tunnels for the DB and 3 tunnels for the TB were created in the ACL footprint. The 2 doubled tendon grafts were fixed with EndoButton-CL (Smith & Nephew Endoscopy, Andover, MA) on the femur. The grafts were fixed to the tibia using a Double Spike Plate and a screw under the total initial tension of 20 N at 20° of flexion, after meticulous in situ pretensioning using a tensioning boot. Then immediate postoperative anterior knee laxity in response to 89 N of anterior load was measured by one experienced examiner (T.M.) with the KT-2000 Knee Arthrometer (MEDmedtric, San Diego, CA) under general anesthesia at 30° of knee flexion with muscle relaxants. The measured anterior laxity was 3.4 ± 1.2 mm in the DB and 2.5 ± 0.7 mm in the TB ACL reconstruction, a statistically significant difference. The side-to-side difference of the laxity was -3.2 ± 1.6 mm in the DB and -4.2 ± 2.0 mm in the TB, again a significant difference. TB ACL reconstruction resulted in better immediate postoperative anterior knee stability than DB ACL reconstruction under 89 N of anterior tibial load (P = .031). Level III, therapeutic retrospective comparative study. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  20. Proportional chamber with data analog output

    International Nuclear Information System (INIS)

    Popov, V.E.; Prokof'ev, A.N.

    1977-01-01

    A proportional multiwier chamber is described. The chamber makes it possible to determine angles at wich a pion strikes a polarized target. A delay line, made of 60-core flat cable is used for removing signals from the chamber. From the delay line, signals are amplified and successively injected into shapers and a time-to-amplitude converter. An amplitude of the time-to amplitude converter output signal unambiguously determines the coordinate of a point at which a particle strikes the chamber plane. There are also given circuits of amplifiers, which consist of a preamplifier with gain 30 and a main amplifier with adjustable gain. Data on testing the chamber with the 450 MeV pion beam is demonstrated. The chamber features an efficiency of about 98 per cent under load of 2x10 5 s -1

  1. Gadolinium-enhanced 7.0 T magnetic resonance imaging assessment of the aqueous inflow in rat eyes in vivo.

    Science.gov (United States)

    Li, Lu; Yuan, Yuxiang; Chen, Liwen; Li, Mu; Ji, Pingting; Gong, Jieling; Zhao, Yin; Zhang, Hong

    2017-09-01

    The goal of this study was to calculate the anterior chamber volume and assess aqueous inflow in rat eyes in vivo, under anesthetic condition. Gadolinium-contrast agent (Gd-DTPA, 234.5 mg/ml) was administered to Sprague-Dawley rat eyes via anterior chamber injection or instillation of 234.5 or 117.25 mg/ml Gd-DTPA in 0.2% azone as eye drops, and changes of Gd signal visualized by 7.0 T magnetic resonance imaging (MRI). The safety of local application of Gd-DTPA and azone were performed after MRI scanning. The anterior chamber injection of Gd-DTPA (234.5 mg/ml) group was used for anterior chamber volume and aqueous inflow calculating. Serial changes in Gd-DTPA relative concentration in the anterior chamber was determined based on the initial Gd signal gray values and the initial relative concentration of Gd-DTPA after anterior chamber Gd-DTPA injection. The mean aqueous inflow in rat eyes in vivo was assessed based on changes in Gd-DTPA relative concentration and the anterior chamber volume. Eye drops of Gd-DTPA (234.5 mg/ml) in 0.2% azone readily allowed safe assessment of the aqueous inflow by 7.0 T MRI. Under anesthetic condition in vivo, the mean anterior chamber volume (ACV) in rats was 8493.6 ± 657.4 μm 3 , no differences were observed in the aqueous inflow measured by topical instillation of 234.5 mg/ml Gd-DTPA in 0.2% azone (0.182 ± 0.011 μl/min) between that measured by anterior chamber injection (0.165 ± 0.041 μl/min, P > 0.05), Timolol reduced aqueous inflow to 0.124 ± 0.020 μl/min (P DTPA can be assessed by the variability of relative concentration of Gd-DTPA in anterior chamber and ACV in vivo, under anesthetic condition. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  3. Proton beam monitor chamber calibration

    International Nuclear Information System (INIS)

    Gomà, C; Meer, D; Safai, S; Lorentini, S

    2014-01-01

    The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic proton beam. For the latter, this paper also compares two independent dosimetry techniques to calibrate the beam monitor chambers: absolute dosimetry (of the number of protons exiting the nozzle) with a Faraday cup and reference dosimetry (i.e. determination of the absorbed dose to water under IAEA TRS-398 reference conditions) with an ionization chamber. To compare the two techniques, Monte Carlo simulations were performed to convert dose-to-water to proton fluence. A good agreement was found between the Faraday cup technique and the reference dosimetry with a plane-parallel ionization chamber. The differences—of the order of 3%—were found to be within the uncertainty of the comparison. For cylindrical ionization chambers, however, the agreement was only possible when positioning the effective point of measurement of the chamber at the reference measurement depth—i.e. not complying with IAEA TRS-398 recommendations. In conclusion, for cylindrical ionization chambers, IAEA TRS-398 reference conditions for monoenergetic proton beams led to a systematic error in the determination of the absorbed dose to water, especially relevant for low-energy proton beams. To overcome this problem, the effective point of measurement of cylindrical ionization chambers should be taken into account when positioning the reference point of the chamber. Within the current IAEA TRS-398 recommendations, it seems advisable to use plane-parallel ionization chambers—rather than cylindrical chambers—for the reference dosimetry of pseudo-monoenergetic proton beams. (paper)

  4. Nodular Scleritis Associated with Herpes Zoster Virus: An Infectious and Immune-Mediated Process

    Directory of Open Access Journals (Sweden)

    Mónica Loureiro

    2016-01-01

    Full Text Available Purpose. To describe a case of anterior nodular scleritis, preceded by an anterior hypertensive uveitis, which was primarily caused by varicella zoster virus (VZV. Case Report. A 54-year-old woman presented with anterior uveitis of the right eye presumably caused by herpetic viral disease and was successfully treated. Two months later, she developed a nodular scleritis and started oral nonsteroidal anti-inflammatory without effect. A complete laboratory workup revealed positivity for HLA-B27; the infectious workup was negative. Therapy was changed to oral prednisolone and an incomplete improvement occurred. Therefore, a diagnostic anterior paracentesis was performed and the polymerase chain reaction (PCR analysis revealed VZV. She was treated with valacyclovir and the oral prednisolone began to decrease; however, a marked worsening of the scleritis occurred with the reduction of the daily dose; subsequently, methotrexate was introduced allowing the suspension of the prednisolone and led to clinical resolution of the scleritis. Conclusion. This report of anterior nodular scleritis caused by VZV argues in favor of an underlying immune-mediated component, requiring immunosuppressive therapy for clinical resolution. The PCR analysis of the aqueous humor was revealed to be a valuable technique and should be considered in cases of scleritis with poor response to treatment.

  5. Persistent Corneal Decompensation due to Anterior Dislocation of Soemmering Ring Cataract

    Directory of Open Access Journals (Sweden)

    Travis Peck

    2017-01-01

    Full Text Available Purpose. We present a case of a patient with Soemmering ring after cataract surgery and a potential complication that can arise as a result of its presence. Observations. A patient with history of ruptured globe status after repair and lensectomy, complicated by aphakic secondary open angle glaucoma, was referred for management of second injury to the same eye. This injury resulted in Soemmering ring dislocation into the anterior chamber. The cortical material caused a significant increase in intraocular pressure and corneal decompensation. Surgical removal of the Soemmering ring and Ahmed glaucoma tube implant was performed with control of intraocular pressures; however corneal edema could not be reversed. Conclusions and Importance. This case report illustrates the serious consequences that can be caused by Soemmering rings without early surgical intervention. Care must be taken to completely remove cortical material during cataract surgery to prevent their formation.

  6. Iris en sayuela signo clínico nuevo asociado al síndrome tóxico del segmento anterior: a new clinical sign associated to the anterior segment toxic syndrome Iris in underskirt

    Directory of Open Access Journals (Sweden)

    Iván Hernández López

    2010-01-01

    Full Text Available OBJETIVO: Presentar un nuevo signo clínico como resultado del desprendimiento gigante del epitelio pigmentado posterior del iris en el curso de un síndrome tóxico del segmento anterior tras una cirugía de catarata. MÉTODOS: Presentamos un paciente intervenido de catarata mediante facoemulsificación con implante de lente intraocular de cámara posterior plegable, sin incidencias ni complicaciones transoperatorias. Se le realizó evaluación biomicroscópica en el posoperatorio inmediato diagnosticándosele un síndrome tóxico del segmento anterior asociado a un desprendimiento gigante del epitelio pigmentado posterior del iris. Se tomaron fotos durante la evolución del paciente para documentar este raro signo clínico. RESULTADOS: Al provocar la dilatación pupilar farmacológica nos encontramos con la retracción de todas las capas anteriores del iris, mostrando por debajo al epitelio pigmentado posterior del iris sinequiado al lente intraocular y tan extensamente desprendido que simulaba un segundo iris. No encontramos este hallazgo clínico reportado en la literatura revisada. Denominamos este signo como iris en sayuela. CONCLUSIONES: El desprendimiento del epitelio pigmentado posterior del iris constituye un hallazgo clínico que puede aparecer raramente asociado al síndrome tóxico del segmento anterior y cuando es muy extenso puede presentarse de forma insólita como el signo del iris en sayuela.OBJECTIVE: To present a new clinical sign as a result of a huge posterior pigmented epithelium detachment of the iris in the course of at toxic anterior segment syndrome after a successful cataract surgery. METHOD: A patient who had undergone a cataract surgery by phacoemulsification with posterior chamber foldable intraocular lens implantation, without any incidence or transoperative complication. He was evaluated through biomicroscopy in the immediate postoperative period where a huge posterior pigmented epithelium detachment of the iris

  7. 38 CFR 3.379 - Anterior poliomyelitis.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Anterior poliomyelitis. 3... Specific Diseases § 3.379 Anterior poliomyelitis. If the first manifestations of acute anterior poliomyelitis present themselves in a veteran within 35 days of termination of active military service, it is...

  8. The Efficacy of Bulbar Urethral Mobilization for Anastomotic Anterior Urethroplasty in a Case With Recurrent Anterior Urethral Stricture

    OpenAIRE

    Fukui, Shinji; Aoki, Katsuya; Kaneko, Yoshiteru; Samma, Shoji; Fujimoto, Kiyohide

    2014-01-01

    A 2-month-old boy was diagnosed with febrile urinary tract infection. Voiding cystourethrography showed bulbar and anterior urethral strictures, and endoscopic internal urethrotomy was performed. He developed febrile urinary tract infection again and revealed the recurrence of the anterior urethral stricture. Consequently, endoscopic internal urethrotomy was performed 4 times. Because the anterior urethral stricture had not improved, he was referred to us. Anterior urethroplasty was performed...

  9. Pressure vessel rupture within a chamber: the pressure history on the chamber wall

    International Nuclear Information System (INIS)

    Baum, M.R.

    1989-04-01

    Generally there is a large number of pressure vessels containing high pressure gas on power stations and chemical plant. In many instances, particularly on power plant, these vessels are within the main building. If a pressure vessel were to fail, the surrounding structures would be exposed to blast loads and the forces resulting from jets of fluid issuing from the breached vessel. In the case where the vessel is in a relatively closed chamber there would also be a general overpressurisation of the chamber. At the design stage it is therefore essential to demonstrate that the plant could be safely shut down in the event of a pressure vessel failure, that is, it must be shown that the chamber will not collapse thus putting the building at risk or hazarding equipment essential for a safe shut down. Such an assessment requires the loads applied to the chamber walls, roof, etc. to be known. (author)

  10. Wet drift chambers for precise luminosity

    International Nuclear Information System (INIS)

    Anderson, B.E.; Kennedy, B.W.; Ahmet, K.; Attree, D.J.; Barraclough, G.A.; Cresswell, M.J.; Hayes, D.A.; Miller, D.J.; Selby, C.; Sherwood, P.

    1994-01-01

    A set of high-precision compact drift chambers has been a vital component of the OPAL luminosity monitor since the start of data-taking at LEP. They were augmented in 1992 by the addition of Small Angle Reference Chambers with a very similar design to the original chamber. The performance of the chambers is reviewed, highlighting both the importance of using polyalkylene glycol (Breox) to maintain a uniform and parallel electric field and the construction techniques used to sustain the required field strength. We describe some of the operating problems, with their solutions, and show how the chambers have been used in achieving a systematic error of 0.41% on the luminosity measurement. ((orig.))

  11. The Boycott effect in magma chambers

    Science.gov (United States)

    Blanchette, F.; Peacock, T.; Bush, J. W. M.

    2004-03-01

    We investigate the plausibility of the stratified Boycott effect as a source of layering in magma chambers. Crystal settling within the magma chamber will generate buoyant fluid near the sloping sidewalls whose vertical ascent may be limited by the ambient stratification associated with vertical gradients in SiO2. The resulting flow may be marked by a layered structure, each layer taking the form of a convection cell spanning the lateral extent of the magma chamber. Using parameters relevant to magma chambers, we estimate that such convection cells would be established over a timescale of a month and have a depth on the order of 4m, which is roughly consistent with field observations of strata within solidified chambers.

  12. The KEK 1 m hydrogen bubble chamber

    International Nuclear Information System (INIS)

    Doi, Yoshikuni; Araoka, Osamu; Hayashi, Kohei; Hayashi, Yoshio; Hirabayashi, Hiromi.

    1978-03-01

    A medium size hydrogen bubble chamber has been constructed at the National Laboratory for High Energy Physics, KEK. The bubble chamber has been designed to be operated with a maximum rate of three times per half a second in every two second repetition time of the accelerator, by utilizing a hydraulic expansion system. The bubble chamber has a one meter diameter and a visible volume of about 280 l. A three-view stereo camera system is used for taking photographic pictures of the chamber. A 2 MW bubble chamber magnet is constructed. The main part of the bubble chamber vessel is supported by the magnet yoke. The magnet gives a maximum field of 18.4 kG at the centre of the fiducial volume of the chamber. The overall system of the KEK 1 m hydrogen bubble chamber facility is described in some detail. Some operational characteristics of the facility are also reported. (auth.)

  13. Loss of ions in cavity ionization chambers

    International Nuclear Information System (INIS)

    Takata, N.; Tran, N.T.; Kim, E.; Marsoem, P.; Kurosawa, T.; Koyama, Y.

    2005-01-01

    Ion losses due to initial recombination, volume recombination, and back diffusion were each determined by measurements and calculations for different size cylindrical ionization chambers and spherical ionization chambers. By measuring signal currents from these ionization chambers irradiated with 60 Co gamma rays, two groups of ion losses were obtained. (Group 1) Ion loss due to initial recombination and diffusion, which changes proportionally to the inverse of the voltage applied to the ionization chambers; (and group 2) ion loss due to volume recombination, which changes proportionally to the inverse of the square of the applied voltage. The diffusion loss was obtained separately by computing electric field distributions in the ionization chambers. It was found that diffusion loss is larger than initial recombination loss for the cylindrical ionization chambers and vise versa for the spherical ionization chambers

  14. Investigation of very long jet chambers

    Energy Technology Data Exchange (ETDEWEB)

    Burckhart, H J; Va' vra, J; Zankel, K; Dudziak, U; Schaile, D; Schaile, O; Igo-Kemenes, P; Lennert, P

    1986-04-01

    The electrostatic properties and the performances of very long jet chambers have been investigated. Using 100 MHz FADC wave form digitisers, the tracking accuracy, the charge division and the dE/dx performance of two chambers, one with 4.5 m long tungsten wires and one with 4 m long highly resistive ''NiCoTi'' wires have been studied. The geometry of the chambers was chosen to define some of the design parameters of the jet chamber for the OPAL detector for LEP.

  15. IFE chamber technology testing program in NIF and chamber development test plan

    International Nuclear Information System (INIS)

    Abdou, M.A.

    1995-01-01

    Issues concerning chamber technology testing program in NIF involving: criteria for evaluation/prioritization of experiments, engineering scaling requirements for test article design and material selection and R and D plan prior to NIF testing were addressed in this paper. In order to maximize the benefits of testing program in NIF, the testing in NIF should provide the experimental data relevant to DEMO design choice or to DEMO design predictive capability by utilizing engineering scaling test article designs. Test plans were developed for 2 promising chamber design concepts. Early testing in non-fusion/non-ignition prior to testing in ignition facility serves a critical role in chamber R and D test plans in order to reduce the risks and costs of the more complex experiments in NIF

  16. Impedances in lossy elliptical vacuum chambers

    International Nuclear Information System (INIS)

    Piwinski, A.

    1994-04-01

    The wake fields of a bunched beam caused by the resistivity of the chamber walls are investigated for a vacuum chamber with elliptical cross section. The longitudinal and transverse impedances are calculated for arbitrary energies and for an arbitrary position of the beam in the chamber. (orig.)

  17. Long anterior zonules and pigment dispersion.

    Science.gov (United States)

    Moroi, Sayoko E; Lark, Kurt K; Sieving, Paul A; Nouri-Mahdavi, Kouros; Schlötzer-Schrehardt, Ursula; Katz, Gregory J; Ritch, Robert

    2003-12-01

    To describe pigment dispersion associated with long anterior zonules. Multicenter observational case series. Fifteen patients, seven of whom were treated for glaucoma or ocular hypertension, were identified with long anterior zonules and pigment dispersion. Transmission electron microscopy was performed on one anterior capsule specimen. All patients had anterior zonules that inserted centrally on the lens capsule. Signs of pigment dispersion included corneal endothelial pigmentation, loss of the pupillary ruff, and variable trabecular meshwork pigmentation. Ultrasound biomicroscopy verified the lack of posterior iris insertion and concavity. There was no exfoliation material. Transmission electron microscopy showed zonular lamellae with adherent pigment granules, and no exfoliation material. Long anterior zonules inserted onto the central lens capsule may cause mechanical disruption of the pigment epithelium at the pupillary ruff and central iris leading to pigment dispersion.

  18. Fenestration of the anterior cerebral artery

    International Nuclear Information System (INIS)

    Ito, J.; Washiyama, K.; Hong Kim, C.; Ibuchi, Y.

    1981-01-01

    Three cases of angiographically demonstrated fenestration of the anterior cerebral artery are reported. Fenestration occurred at the medial half of the horizontal segment of the anterior cerebral artery in all cases. Its embryology and clinical significance are briefly discussed, and the anatomical and radiological literature on fenestration of the anterior cerebral artery is reviewed. (orig.)

  19. The Efficacy of Bulbar Urethral Mobilization for Anastomotic Anterior Urethroplasty in a Case With Recurrent Anterior Urethral Stricture.

    Science.gov (United States)

    Fukui, Shinji; Aoki, Katsuya; Kaneko, Yoshiteru; Samma, Shoji; Fujimoto, Kiyohide

    2014-05-01

    A 2-month-old boy was diagnosed with febrile urinary tract infection. Voiding cystourethrography showed bulbar and anterior urethral strictures, and endoscopic internal urethrotomy was performed. He developed febrile urinary tract infection again and revealed the recurrence of the anterior urethral stricture. Consequently, endoscopic internal urethrotomy was performed 4 times. Because the anterior urethral stricture had not improved, he was referred to us. Anterior urethroplasty was performed when he was 5 years. After excision of the scarred portions of the urethra, the defect of the urethra was 20 mm. Transperineal bulbar urethral mobilization was performed, and a single-stage end-to-end anterior urethroplasty without tension could be performed simultaneously.

  20. Investigation of very long jet chambers

    Energy Technology Data Exchange (ETDEWEB)

    Burckhart, H J; Va' vra, J; Zankel, K; Dudziak, U; Schaile, D; Schaile, O; Igo-Kemenes, P; Lennert, P

    1986-04-01

    The electrostatic properties and the performances of very long jet chambers have been investigated. Using 100 MHz FADC wave form digitisers, the tracking accuracy, the charge division and the dE/dx performance of two chambers, one with 4.5 m long tungsten wires and one with 4 m long highly resistive ''NiCoTi'' wires have been studied. The geometry of the chambers was chosen to define some of the design parameters of the jet chamber for the OPAL detector for LEP. (orig.).

  1. Chamber propagation physics for heavy ion fusion

    International Nuclear Information System (INIS)

    Callahan, D.A.

    1995-01-01

    Chamber transport is an important area of study for heavy ion fusion. Final focus and chamber-transport are high leverage areas providing opportunities to significantly decrease the cost of electricity from a heavy ion fusion power plant. Chamber transport in two basic regimes is under consideration. In the low chamber density regime (approx-lt 0.003 torr), ballistic or nearly-ballistic transport is used. Partial beam neutralization has been studied to offset the effects of beam stripping. In the high chamber density regime (approx-gt.1 torr), two transport modes (pinched transport and channel transport) are under investigation. Both involve focusing the beam outside the chamber then transporting it at small radius (∼ 2 mm). Both high chamber density modes relax the constraints on the beam quality needed from the accelerator which will reduce the driver cost and the cost of electricity

  2. Multiwire proportional chamber and multistage avalanche chamber with low concentration photoionization gas

    International Nuclear Information System (INIS)

    Zhao Pingde; Xu Zhiqing; Tang Xiaowei

    1986-01-01

    The characteristics of multiwire proportional chamber and multistage avalanche chamber filled with argon and photoionization gas (C 2 H 5 ) 3 N were measured. The spatial resolution curves and output pulse height spectra were measured as well. Low concentration (C 2 H 5 ) 3 N can play an effective part in quenching. At very low concentration, the phenomena of avalanche transverse expansion was observed obviously

  3. PEP quark search proportional chambers

    Energy Technology Data Exchange (ETDEWEB)

    Parker, S I; Harris, F; Karliner, I; Yount, D [Hawaii Univ., Honolulu (USA); Ely, R; Hamilton, R; Pun, T [California Univ., Berkeley (USA). Lawrence Berkeley Lab.; Guryn, W; Miller, D; Fries, R [Northwestern Univ., Evanston, IL (USA)

    1981-04-01

    Proportional chambers are used in the PEP Free Quark Search to identify and remove possible background sources such as particles traversing the edges of counters, to permit geometric corrections to the dE/dx and TOF information from the scintillator and Cerenkov counters, and to look for possible high cross section quarks. The present beam pipe has a thickness of 0.007 interaction lengths (lambdasub(i)) and is followed in both arms each with 45/sup 0/ <= theta <= 135/sup 0/, ..delta..phi=90/sup 0/ by 5 proportional chambers, each 0.0008 lambdasub(i) thick with 32 channels of pulse height readout, and by 3 thin scintillator planes, each 0.003 lambdasub(i) thick. Following this thin front end, each arm of the detector has 8 layers of scintillator (one with scintillating light pipes) interspersed with 4 proportional chambers and a layer of lucite Cerenkov counters. Both the calculated ion statistics and measurements using He-CH/sub 4/ gas in a test chamber indicate that the chamber efficiencies should be >98% for q=1/3. The Landau spread measured in the test was equal to that observed for normal q=1 traversals. One scintillator plane and thin chamber in each arm will have an extra set of ADC's with a wide gate bracketing the normal one so timing errors and tails of earlier pulses should not produce fake quarks.

  4. Argus target chamber

    International Nuclear Information System (INIS)

    Rienecker, F. Jr.; Glaros, S.S.; Kobierecki, M.

    1975-01-01

    A target chamber for application in the laser fusion program must satisfy some very basic requirements. (1) Provide a vacuum on the order of 10 -6 torr. (2) Support a microscopically small target in a fixed point in space and verify its location within 5 micrometers. (3) Contain an adjustable beam focusing system capable of delivering a number of laser beams onto the target simultaneously, both in time and space. (4) Provide access for diagnostics to evaluate the results of target irradiation. (5) Have flexibility to allow changes in targets, focusing optics and number of beams. The ARGUS laser which is now under construction at LLL will have a target chamber which meets these requirements in a simple economic manner. The chamber and auxiliary equipment are described, with reference to two double beam focusing systems; namely, lenses and ellipsoidal mirrors. Provision is made for future operation with four beams, using ellipsoidal mirrors for two-sided illumination and lens systems for tetragonal and tetrahedral irradiation

  5. Herniation of the anterior lens capsule

    Directory of Open Access Journals (Sweden)

    Pereira Nolette

    2007-01-01

    Full Text Available Herniation of the anterior lens capsule is a rare abnormality in which the capsule bulges forward in the pupillary area. This herniation can be mistaken for an anterior lenticonus where both the capsule and the cortex bulge forward. The exact pathology behind this finding is still unclear. We report the clinical, ultrasound biomicroscopy (UBM and histopathological findings of a case of herniation of the anterior lens capsule. UBM helped to differentiate this entity from anterior lenticonus. Light microscopy revealed capsular splitting suggestive of capsular delamination and collection of fluid (aqueous in the area of herniation giving it a characteristic appearance.

  6. Cylindrical ionization chamber with compressed krypton

    International Nuclear Information System (INIS)

    Kuz'minov, V.V.; Novikov, V.M.; Pomanskii, A.A.; Pritychenko, B.V.; Viyar, J.; Garcia, E.; Morales, A.; Morales, J.; Nunes-Lagos, R.; Puimedon, J.; Saens, K.; Salinas, A.; Sarsa, M.

    1993-01-01

    A cylindrical ionization chamber with a grid is used to search for double positron decay and atomic electron conversion to a positron in 78 Kr. Krypton is the working gas material of the chamber. The spectrometric characteristics of the chamber filled with krypton and xenon are presented. The energy resolution is 2.1% for an energy of 1.84 MeV (the source of γ-quanta is 88 Y) when the chamber is filled with a mixture of Kr+0.2% H 2 under a pressure of 25 atm

  7. Advances on fission chamber modelling

    International Nuclear Information System (INIS)

    Filliatre, Philippe; Jammes, Christian; Geslot, Benoit; Veenhof, Rob

    2013-06-01

    In-vessel, online neutron flux measurements are routinely performed in mock-up and material testing reactors by fission chambers. Those measurements have a wide range of applications, including characterization of experimental conditions, reactor monitoring and safety. Depending on the application, detectors may experience a wide range of constraints, of several magnitudes, in term of neutron flux, gamma-ray flux, temperature. Hence, designing a specific fission chamber and measuring chain for a given application is a demanding task. It can be achieved by a combination of experimental feedback and simulating tools, the latter being based on a comprehensive understanding of the underlying physics. A computation route that simulates fission chambers, named CHESTER, is presented. The retrieved quantities of interest are the neutron-induced charge spectrum, the electronic and ionic pulses, the mean current and variance, the power spectrum. It relies on the GARFIELD suite, originally developed for drift chambers, and makes use of the MAGBOLTZ code to assess the drift parameters of electrons within the filling gas, and the SRIM code to evaluate the stopping range of fission products. The effect of the gamma flux is also estimated. Computations made with several fission chambers exemplify the possibilities of the route. A good qualitative agreement is obtained when comparing the results with the experimental data available to date. In a near future, a comprehensive experimental programme will be undertaken to qualify the route using the known neutron sources, mock-up reactors and wide choice of fission chambers, with a stress on the predictiveness of the Campbelling mode. Depending on the results, a refinement of the modelling and an effort on the accuracy of input data are also to be considered. CHESTER will then make it possible to predict the overall sensitivity of a chamber, and to optimize the design for a given application. Another benefit will be to increase the

  8. An electrodeless drift chamber

    International Nuclear Information System (INIS)

    Allison, J.; Barlow, R.J.; Bowdery, C.K.; Duerdoth, I.; Rowe, P.G.

    1982-01-01

    We describe a chamber in which the drift field is controlled by the deposition of electrostatic charge on an insulating surface. The chamber operates with good efficiency and precision for observed drift distances of up to 45 cm, promises to be extremely robust and adaptable and offers a very cheap way of making particle detectors. (orig.)

  9. DELPHI time projection chamber

    CERN Multimedia

    1989-01-01

    The time projection chamber is inserted inside the central detector of the DELPHI experiment. Gas is ionised in the chamber as a charged particle passes through, producing an electric signal from which the path of the particle can be found. DELPHI, which ran from 1989 to 2000 on the LEP accelerator, was primarily concerned with particle identification.

  10. Multidisciplinary management of anterior diastemata

    DEFF Research Database (Denmark)

    Furuse, Adilson Yoshio; Herkrath, Fernando José; Franco, Eduardo Jacomino

    2007-01-01

    Anterior diastemata may compromise the harmony of a patient's smile. Consideration of etiologic factors, previous gingival conditioning, and individual treatment planning are essential in the proper management of anterior diastemata. An integrated orthodontic-restorative approach may enhance the ...

  11. Chamber propagation physics for heavy ion fusion

    International Nuclear Information System (INIS)

    Callahan, D.A.

    1996-01-01

    Chamber transport is a key area of study for heavy ion fusion. Final focus and chamber transport are high leverage areas providing opportunities to decrease significantly the cost of electricity from a heavy ion fusion power plant. Chamber transport in two basic regimes is under consideration. In the low chamber density regime (below about 0.003 Torr), ballistic or nearly ballistic transport is used. Partial beam neutralization has been studied to offset the effects of beam stripping. In the high chamber density regime (above about 0.1 Torr), two transport modes (pinched transport and channel transport) are under investigation. Both involve focusing the beam outside the chamber and then transporting it at small radius (about 2 mm). Both high chamber density modes relax the constraints on the beam quality needed from the accelerator which will reduce the driver cost and the cost of electricity. (orig.)

  12. The Efficacy of Bulbar Urethral Mobilization for Anastomotic Anterior Urethroplasty in a Case With Recurrent Anterior Urethral Stricture

    Directory of Open Access Journals (Sweden)

    Shinji Fukui

    2014-05-01

    Full Text Available A 2-month-old boy was diagnosed with febrile urinary tract infection. Voiding cystourethrography showed bulbar and anterior urethral strictures, and endoscopic internal urethrotomy was performed. He developed febrile urinary tract infection again and revealed the recurrence of the anterior urethral stricture. Consequently, endoscopic internal urethrotomy was performed 4 times. Because the anterior urethral stricture had not improved, he was referred to us. Anterior urethroplasty was performed when he was 5 years. After excision of the scarred portions of the urethra, the defect of the urethra was 20 mm. Transperineal bulbar urethral mobilization was performed, and a single-stage end-to-end anterior urethroplasty without tension could be performed simultaneously.

  13. How to build a cloud chamber?

    International Nuclear Information System (INIS)

    Mariaud, C.

    2012-01-01

    The cloud chamber had its heyday in the first half of last century and allowed the discovery of new particles such as the anti-electron, the muon and the neutral and the charged kaon. The bubble chamber replaced it in the mid fifties. This article recalls the principle of the cloud chamber and shows, in a detailed way, how to proceed to build one with on-the-shelf materials. This design is based on the use of isopropanol whose liquefaction through the form of droplets materializes the track of the particle and on the use of combined Peltier cells (instead of CO 2 snow) to cool the chamber. This cloud chamber has been successfully used in schools to observe particles mainly electrons, alphas and muons generated by cosmic rays. (A.C.)

  14. A mathematical model of aerosol holding chambers

    DEFF Research Database (Denmark)

    Zak, M; Madsen, J; Berg, E

    1999-01-01

    A mathematical model of aerosol delivery from holding chambers (spacers) was developed incorporating tidal volume (VT), chamber volume (Vch), apparatus dead space (VD), effect of valve insufficiency and other leaks, loss of aerosol by immediate impact on the chamber wall, and fallout of aerosol...... in the chamber with time. Four different spacers were connected via filters to a mechanical lung model, and aerosol delivery during "breathing" was determined from drug recovery from the filters. The formula correctly predicted the delivery of budesonide aerosol from the AeroChamber (Trudell Medical, London...

  15. Quality control of ATLAS muon chambers

    CERN Document Server

    Fabich, Adrian

    ATLAS is a general-purpose experiment for the future Large Hadron Collider (LHC) at CERN. Its Muon Spectrometer will require ∼ 5500m2 of precision tracking chambers to measure the muon tracks along a spectrometer arm of 5m to 15m length, embedded in a magnetic field of ∼ 0.5T. The precision tracking devices in the Muon System will be high pressure drift tubes (MDTs). Approximately 370,000 MDTs will be assembled into ∼ 1200 drift chambers. The performance of the MDT chambers is very much dependent on the mechanical quality of the chambers. The uniformity and stability of the performance can only be assured providing very high quality control during production. Gas tightness, high-voltage behaviour and dark currents are global parameters which are common to gas detectors. For all chambers, they will be tested immediately after the chamber assembly at every production site. Functional tests, for example radioactive source scans and cosmic-ray runs, will be performed in order to establish detailed performan...

  16. Hyperbaric and hypobaric chamber fires: a 73-year analysis.

    Science.gov (United States)

    Sheffield, P J; Desautels, D A

    1997-09-01

    Fire can be catastrophic in the confined space of a hyperbaric chamber. From 1923 to 1996, 77 human fatalities occurred in 35 hyperbaric chamber fires, three human fatalities in a pressurized Apollo Command Module, and two human fatalities in three hypobaric chamber fires reported in Asia, Europe, and North America. Two fires occurred in diving bells, eight occurred in recompression (or decompression) chambers, and 25 occurred in clinical hyperbaric chambers. No fire fatalities were reported in the clinical hyperbaric chambers of North America. Chamber fires before 1980 were principally caused by electrical ignition. Since 1980, chamber fires have been primarily caused by prohibited sources of ignition that an occupant carried inside the chamber. Each fatal chamber fire has occurred in an enriched oxygen atmosphere (> 28% oxygen) and in the presence of abundant burnable material. Chambers pressurized with air (Hyperbaric Medical Society's Chamber Experience and Mishap Database. This epidemiologic review focuses on information learned from critical analyses of chamber fires and how it can be applied to safe operation of hypobaric and hyperbaric chambers.

  17. HVAC&R Equipment Environmental Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — Description:Large "Truck" ChamberThe large "truck" chamber provides controlled air conditions from -7 °C (20 °F) to 65 °C (150 °F).Air-Conditioner and Heat Pump Test...

  18. Micro plate fission chamber development

    International Nuclear Information System (INIS)

    Wang Mei; Wen Zhongwei; Lin Jufang; Jiang Li; Liu Rong; Wang Dalun

    2014-01-01

    To conduct the measurement of neutron flux and the fission rate distribution at several position in assemblies, the micro plate fission chamber was designed and fabricated. Since the requirement of smaller volume and less structure material was taken into consideration, it is convinient, commercial and practical to use fission chamber to measure neutron flux in specific condition. In this paper, the structure of fission chamber and process of fabrication were introduced and performance test result was presented. The detection efficiency is 91.7%. (authors)

  19. Ionization chamber for smoke detector and the like

    International Nuclear Information System (INIS)

    Rork, G.D.; Thorp, E.J.; Zegarski, R.J.

    1985-01-01

    This invention relates to detectors of the ionization type for detecting airborne particulate matter and, in particular, to the construction of an ionization chamber for such a detector. This invention may be used for detecting a variety of materials, such as dust, fog and the like, but is particularly useful for detecting combustion products such as smoke. The smoke detector ionization chamber has two electrodes connected to a source of electric power; means defining access openings for enabling air flow into and out of the chamber; and means for causing ionization within the chamber. It has control structure means within the chamber in the path of the airflow cooperating with the electrodes to establish within the chamber an electric field having a higher intensity close to the access openings and a lower intensity in the remainder of the chamber without significantly impairing the flow of neutral particles into the chamber. The control structure reduces airflow velocity within the chamber without adversely affecting the access of airborne particles to the chamber

  20. Liquid Wall Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Meier, W R

    2011-02-24

    The key feature of liquid wall chambers is the use of a renewable liquid layer to protect chamber structures from target emissions. Two primary options have been proposed and studied: wetted wall chambers and thick liquid wall (TLW) chambers. With wetted wall designs, a thin layer of liquid shields the structural first wall from short ranged target emissions (x-rays, ions and debris) but not neutrons. Various schemes have been proposed to establish and renew the liquid layer between shots including flow-guiding porous fabrics (e.g., Osiris, HIBALL), porous rigid structures (Prometheus) and thin film flows (KOYO). The thin liquid layer can be the tritium breeding material (e.g., flibe, PbLi, or Li) or another liquid metal such as Pb. TLWs use liquid jets injected by stationary or oscillating nozzles to form a neutronically thick layer (typically with an effective thickness of {approx}50 cm) of liquid between the target and first structural wall. In addition to absorbing short ranged emissions, the thick liquid layer degrades the neutron flux and energy reaching the first wall, typically by {approx}10 x x, so that steel walls can survive for the life of the plant ({approx}30-60 yrs). The thick liquid serves as the primary coolant and tritium breeding material (most recent designs use flibe, but the earliest concepts used Li). In essence, the TLW places the fusion blanket inside the first wall instead of behind the first wall.

  1. Resultados del tratamiento quirúrgico de los aneurismas del complejo cerebral anterior-arteria comunicante anterior

    Directory of Open Access Journals (Sweden)

    Armando Alemán Rivera

    2001-06-01

    Full Text Available Se realiza un estudio de 30 pacientes con aneurismas localizados en el complejo de la arteria cerebral anterior-arteria comunicante anterior (ACoA, operados en el Servicio de Neurocirugía del Hospital Universitario "Arnaldo Milián Castro", durante un período de 7 años. Se analizan variables tales como edad, sexo, estado neurológico preoperatorio, momento quirúrgico, complicaciones y estado al egreso. La mortalidad general fue del 10 %The authors carried out a study in 30 patients with aneurysms located in the anterior communicating artery-anterior cerebral complex (ACA-ACC, that were operated on at the Neurosurgery Service of "Arnaldo Milián Castro" Teaching Hospital, during a period of 7 years. Variables such as age, sex, preoperative neurologic state, surgical moment, complications and status on discharge were analyzed. General mortality was 10 %

  2. High resolution drift chambers

    International Nuclear Information System (INIS)

    Va'vra, J.

    1985-07-01

    High precision drift chambers capable of achieving less than or equal to 50 μm resolutions are discussed. In particular, we compare so called cool and hot gases, various charge collection geometries, several timing techniques and we also discuss some systematic problems. We also present what we would consider an ''ultimate'' design of the vertex chamber. 50 refs., 36 figs., 6 tabs

  3. Combination nivolumab- and cabiralizumab-associated acute bilateral anterior and posterior scleritis and anterior uveitis

    Directory of Open Access Journals (Sweden)

    John A. Gonzales

    2018-06-01

    Full Text Available Purpose: To report on a case of uveitis and scleritis resulting as an immune-mediated side effect of cancer immunotherapy with nivolumab and cabiralizumab. Observations: Bilateral anterior nongranulomatous anterior uveitis and bilateral diffuse anterior and posterior scleritis occurred following the use of combination cancer immunotherapy. The uveitis and scleritis resolved following temporary discontinuation of nivolumab and cabiralizumab as well as systemic prednisone. Conclusions and importance: Ophthalmologists should be aware of the possibility of acute ocular inflammation developing with cancer immunotherapy. Systemic corticosteroids play a first-line role in managing such immune-mediated side effects. Keywords: Uveitis, Scleritis, Cancer immunotherapy, Side effects, Nivolumab, Cabiralizumab

  4. The Mark II Vertex Drift Chamber

    International Nuclear Information System (INIS)

    Alexander, J.P.; Baggs, R.; Fujino, D.

    1989-03-01

    We have completed constructing and begun operating the Mark II Drift Chamber Vertex Detector. The chamber, based on a modified jet cell design, achieves 30 μm spatial resolution and 2 gas mixtures. Special emphasis has been placed on controlling systematic errors including the use of novel construction techniques which permit accurate wire placement. Chamber performance has been studied with cosmic ray tracks collected with the chamber located both inside and outside the Mark II. Results on spatial resolution, average pulse shape, and some properties of CO 2 mixtures are presented. 10 refs., 12 figs., 1 tab

  5. Bicone vacuum chamber for ISR intersection

    CERN Multimedia

    1975-01-01

    This is one of the bicone chambers made of titanium for experiment R 702. The central corrugated part had a very thin titanium wall (0.28 mm). The first of these chambers collapsed in its central part when baked at 300 C (August 1975). After an intensive effort to develop better quality and reproducible welds for this special material, the ISR workshop was able to build two new chambers of this type. One of them was installed at I 7 for R 702 in 1976 and worked perfectly. It was at that time the most "transparent" intersection vacuum chamber. See also 7609219, 7609221.

  6. Anterior spinal cord syndrome of unknown etiology

    OpenAIRE

    Klakeel, Merrine; Thompson, Justin; Srinivasan, Rajashree; McDonald, Frank

    2015-01-01

    A spinal cord injury encompasses a physical insult to the spinal cord. In the case of anterior spinal cord syndrome, the insult is a vascular lesion at the anterior spinal artery. We present the cases of two 13-year-old boys with anterior spinal cord syndrome, along with a review of the anatomy and vasculature of the spinal cord and an explanation of how a lesion in the cord corresponds to anterior spinal cord syndrome.

  7. Growing and analyzing biofilms in flow chambers

    DEFF Research Database (Denmark)

    Tolker-Nielsen, Tim; Sternberg, Claus

    2011-01-01

    This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic......, and disassembly and cleaning of the system. In addition, embedding and fluorescent in situ hybridization of flow chamber-grown biofilms are addressed....

  8. Microstrip gas chamber on thin-film Pestov glass and micro gap chamber

    International Nuclear Information System (INIS)

    Gong, W.G.; Harris, J.W.; Wieman, H.

    1994-07-01

    The authors report developments of the Microstrip Gas Chamber on thin-film Pestov glass and the Micro Gap Chamber. By coating a thin-layer of low-resistive, electronically-conductive glass on various substrates (including quartz and ceramics), they built MSGCs of high gain stability and low leakage current. They were tested in Ar-CH 4 (10%) and He-C 2 H 6 (50%) gas mixtures. Energy resolutions of 17-20% were measured for 6keV x-rays. This design can make the choice of substrate less important, save the cost of ion-implantation, and use less glass material. Micro Gap Chamber was successfully tested in He-C 2 H 6 (50%) and Ar-C 2 H 6 (50%) gas mixtures. Energy resolutions of about 20% were obtained. Both detectors are expected to have high rate capability

  9. Comparison among different CT ionization chambers

    International Nuclear Information System (INIS)

    Castro, Maysa C. de; Xavier, Marcos; Caldas, Linda V.E.

    2015-01-01

    The dosimetry in computed tomography (CT) is carried out by the use of a pencil type ionization-chamber, because it has a uniform response at all angles relative to the incident beam of radiation, which is essential for CT equipment since the X-ray tube executes a circular movement around the table during irradiation. The commercial ionization chamber used to perform quality control procedures of this kind of equipment has a length of the sensitive volume of 10 cm. In the Calibration Laboratory of Instruments (LCI) of the IPEN there were already developed some prototypes with small differences in construction, when compared to commercially available ionization chambers. They have been used in previous studies and showed results within internationally acceptable limits. The ionization chambers tested in this study present the sensitive volume lengths of 1 cm, 3 cm and 10 cm. The objective of this study was to present results on the stability test of the three homemade ionization chambers and a commercial chamber, as well to obtain the calibration coefficients for each of them in CT standard X radiation beams. The obtained results for both characterization tests are within the recommended limits, except for the homemade ionization chambers with sensitive volume lengths of 3 cm and 1 cm in the case of the stability test. (author)

  10. Multi-stage low-pressure avalanche chamber

    International Nuclear Information System (INIS)

    Zanevskij, Yu.V.; Peshekhonov, V.D.; Smykov, L.P.

    1985-01-01

    A multi-stage avalanche-chamber filled with isobutane operating at the pressure of 6 torr is described. The chamber comprises an amplifying gap, drift gap and multiwire proportional chamber with interelectrode gaps equal to 4 mm. The anode plane of the proportional chamber is winded of wire 2 μm in diameter with 2 mm pitch. The cathode are winded orthogonally to anode wires of wire 50 μm in diameter with 1 mm pitch. Drift and preamplifier gaps are formed by grid electrodes made of wire 50 μm in diameter with dimension of the cell equal to 1x1 mm. Width of the drift gap is 5 mm, width of the preamplification gap is 3 or 9 mm. Coordinate data are removed from the cathodes of the proportional chamber by means of delay lines. Sensitive square of the chamber equals 240x180 mm. Gas gain coefficient is 3x10 6 at its square nonuniformity equal to approximately 3%. Spatial resolution by both coordinates equals 170 μm; spatial resolution for isotropic α-emitters located close to the preamplifier gap is equal to 500 μm

  11. MRI of tibialis anterior tendon rupture

    International Nuclear Information System (INIS)

    Gallo, Robert A.; DeMeo, Patrick J.; Kolman, Brett H.; Daffner, Richard H.; Sciulli, Robert L.; Roberts, Catherine C.

    2004-01-01

    Ruptures of the tibialis anterior tendon are rare. We present the clinical histories and MRI findings of three recent male patients with tibialis anterior tendon rupture aged 58-67 years, all of whom presented with pain over the dorsum of the ankle. Two of the three patients presented with complete rupture showing discontinuity of the tendon, thickening of the retracted portion of the tendon, and excess fluid in the tendon sheath. One patient demonstrated a partial tear showing an attenuated tendon with increased surrounding fluid. Although rupture of the tibialis anterior tendon is a rarely reported entity, MRI is a useful modality in the definitive detection and characterization of tibialis anterior tendon ruptures. (orig.)

  12. Conditional deletion of AP-2β in mouse cranial neural crest results in anterior segment dysgenesis and early-onset glaucoma

    Directory of Open Access Journals (Sweden)

    Vanessa B. Martino

    2016-08-01

    Full Text Available Anterior segment dysgenesis (ASD encompasses a group of developmental disorders in which a closed angle phenotype in the anterior chamber of the eye can occur and 50% of patients develop glaucoma. Many ASDs are thought to involve an inappropriate patterning and migration of the periocular mesenchyme (POM, which is derived from cranial neural crest cells (NCCs and mesoderm. Although, the mechanism of this disruption is not well understood, a number of transcriptional regulatory molecules have previously been implicated in ASDs. Here, we investigate the function of the transcription factor AP-2β, encoded by Tfap2b, which is expressed in NCCs and their derivatives. Wnt1-Cre-mediated conditional deletion of Tfap2b in NCCs resulted in post-natal ocular defects typified by opacity. Histological data revealed that the conditional AP-2β NCC knockout (KO mutants exhibited dysgenesis of multiple structures in the anterior segment of the eye including defects in the corneal endothelium, corneal stroma, ciliary body and disruption in the iridocorneal angle with adherence of the iris to the cornea. We further show that this phenotype leads to a significant increase in intraocular pressure and a subsequent loss of retinal ganglion cells and optic nerve degeneration, features indicative of glaucoma. Overall, our findings demonstrate that AP-2β is required in the POM for normal development of the anterior segment of the eye and that the AP-2β NCC KO mice might serve as a new and exciting model of ASD and glaucoma that is fully penetrant and with early post-natal onset.

  13. Monitored Drift Chambers in the ATLAS Detector

    CERN Multimedia

    Herten, G

    Monitored Drift Chambers (MDT) are used in the ATLAS Detector to measure the momentum of high energy muons. They consist of drift tubes, which are filled with an Ar-CO2 gas mixture at 3 bar gas pressure. About 1200 drift chambers are required for ATLAS. They are up to 6 m long. Nevertheless the position of every wire needs to be known with a precision of 20 µm within a chamber. In addition, optical alignment sensors are required to measure the relative position of adjacent chambers with a precision of 30µm. This gigantic task seems impossible at first instance. Indeed it took many years of R&D to invent the right tools and methods before the first chamber could be built according to specifications. Today, at the time when 50% of the chambers have been produced, we are confident that the goal for ATLAS can be reached. The mechanical precision of the chambers could be verified with the x-ray tomograph at CERN. This ingenious device, developed for the MDT system, is able to measure the wire position insid...

  14. Humeral avulsion of the anterior shoulder stabilizing structures after anterior shoulder dislocation: demonstration by MRI and MR arthrography

    International Nuclear Information System (INIS)

    Tirman, P.F.J.; Steinbach, L.S.; Feller, J.F.; Stauffer, A.E.

    1996-01-01

    Objective. To demonstrate the MRI findings of an anterior shoulder capsular avulsion from the humerus, with or without subscapularis rupture, after anterior dislocation or severe abduction external rotation injury. Design and patients. We retrospectively reviewed the MRI and MR arthrographic examinations of seven patients who were identified at surgery with avulsion of the anterior shoulder stabilizers from the humerus. MRI was correlated with clinical history and surgical results. Results. MRI findings included: inhomogeneity or frank disruption of the anterior capsule at the humeral insertion (all), fluid intensity anterior to the shoulder (six patients), tear of the subscapularis tendon (six patients), dislocation of the biceps tendon (four patients), and a Hill-Sachs deformity (four patients). MR arthrography additionally found extravasation of contrast through the capsular defect (two patients). Conclusions. Our findings suggest that MRI is helpful for diagnosing humeral avulsion of the anterior glenohumeral capsule, especially when a tear of the subscapularis tendon insertion is present. MR arthrography may be of benefit for diagnosing capsular avulsion without associated subscapularis tendon abnormality. (orig.). With 4 figs

  15. Industrial development of neutron detectors, fission chambers, self powered detectors, ionization chambers

    International Nuclear Information System (INIS)

    Constans, H.; Coville, P.; Guerre, J.

    1975-01-01

    Reactor control requires the determination of neutron flux at all times. The needed characteristics lead to use of several types of detectors: boron lined counters, boron lined ionization chambers, fission ionization chambers and self powered detectors. The principle of the reaction involved the fabrication requirements, the different modes of utilization and the characteristics obtained are examined for each detector. The problem of electric connections in the active area has been solved by developing ''integrated cables'' [fr

  16. Volume-based characterization of postocclusion surge.

    Science.gov (United States)

    Zacharias, Jaime; Zacharias, Sergio

    2005-10-01

    To propose an alternative method to characterize postocclusion surge using a collapsible artificial anterior chamber to replace the currently used rigid anterior chamber model. Fundación Oftamológica Los Andes, Santiago, Chile. The distal end of a phacoemulsification handpiece was placed inside a compliant artificial anterior chamber. Digital recordings of chamber pressure, chamber volume, inflow, and outflow were performed during occlusion break of the phacoemulsification tip. The occlusion break profile of 2 different consoles was compared. Occlusion break while using a rigid anterior chamber model produced a simultaneous increase of chamber inflow and outflow. In the rigid chamber model, pressure decreased sharply, reaching negative pressure values. Alternatively, with the collapsible chamber model, a delay was observed in the inflow that occurs to compensate the outflow surge. Also, the chamber pressure drop was smaller in magnitude, never undershooting below atmospheric pressure into negative values. Using 500 mm Hg as vacuum limit, the Infiniti System (Alcon) performed better that the Legacy (Alcon), showing an 18% reduction in peak volume variation. The collapsible anterior chamber model provides a more realistic representation of the postocclusion surge events that occur in the real eye during cataract surgery. Peak volume fluctuation (mL), half volume recovery time(s), and volume fluctuation integral value (mL x s) are proposed as realistic indicators to characterize the postocclusion surge performance. These indicators show that the Infiniti System has a better postocclusion surge behavior than the Legacy System.

  17. Imaging findings of anterior hip dislocations

    Energy Technology Data Exchange (ETDEWEB)

    Pfeifer, Kyle [Mallinckrodt Institute of Radiology, Department of Radiology, St. Louis, MO (United States); Leslie, Michael [Yale School of Medicine, Department of Orthopedics and Rehabilitation, New Haven, CT (United States); Menn, Kirsten; Haims, Andrew [Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States)

    2017-06-15

    Anterior hip dislocations are rare orthopedic emergencies resulting from high-energy trauma and have unique imaging characteristics on radiography, computed tomography (CT), and magnetic resonance imaging (MRI). Imaging findings on CT and MRI allow for the prompt recognition and classification of anterior hip dislocations, which guides patient management and reduces complications. The purpose of this article is to review imaging findings of anterior hip dislocations, specifically focusing on CT and MRI. (orig.)

  18. A NOVEL ANOMALY OF THE ANTERIOR DIGASTRIC MUSCLE. UNA ANOMALÍA NUEVA DEL MÚSCULO DIGÁSTRICO ANTERIOR

    Directory of Open Access Journals (Sweden)

    Timothy W Hegeman

    2016-03-01

    Full Text Available Documentamos una anomalía del músculo digástrico anterior en un cadáver femenino de 85 años de edad. La anomalía consiste en cuatro vientres adicionales que salen entre los dos típicos digástricos anterior. Analizamos el significado embriológico y clínico de esta variante. El músculo digástrico es derivado de dos arcos branquiales o arcos faríngeos. El primer arco branquial forma el vientre anterior y el segundo forma el vientre posterior. Actuando juntos, los vientres ayudan a impulsar hacia abajo la mandíbula y a estabilizar el hioides. Varias anormalidades en el vientre anterior del digástrico han sido previamente descriptas en la literatura, pero ninguna ha replicado la formación precisa descripta aquí.  We document a novel anomaly of the anterior digastrics of an 85 year old female cadaver, consisting of four additional muscle bellies existing between the two typical anterior digastrics and go on to explain the embryologic and clinical significance of the variant. The digastric muscle is derived from two pharyngeal arches, the first pharyngeal arch forming the anterior belly and the second forming the posterior belly. Acting together, both bellies help to depress the mandible and stabilize the hyoid. Several abnormalities in the anterior belly of the digastric muscle have previously been described in the literature, but none have replicated the precise formation described here.

  19. The little holographic bubble chambers

    International Nuclear Information System (INIS)

    Herve, A.

    1983-01-01

    The lifetime study of the charmed particles has readvanced the idea to use holography for the little fast-cycle bubble chambers. A pilot experiment has been realised in 1982 with a little bubble chamber filled up with freon-115. 40000 holograms have been recorded [fr

  20. Pelletron general purpose scattering chamber

    International Nuclear Information System (INIS)

    Chatterjee, A.; Kailas, S.; Kerekette, S.S.; Navin, A.; Kumar, Suresh

    1993-01-01

    A medium sized stainless steel scattering chamber has been constructed for nuclear scattering and reaction experiments at the 14UD pelletron accelerator facility. It has been so designed that several types of detectors, varying from small sized silicon surface barrier detectors to medium sized gas detectors and NaI detectors can be conveniently positioned inside the chamber for detection of charged particles. The chamber has been planned to perform the following types of experiments : angular distributions of elastically scattered particles, fission fragments and other charged particles, angular correlations for charged particles e.g. protons, alphas and fission fragments. (author). 2 figs

  1. Radon diffusion chamber

    International Nuclear Information System (INIS)

    Pretzsch, G.; Boerner, E.; Lehmann, R.; Sarenio, O.

    1986-01-01

    The invention relates to the detection of radioactive gases emitting alpha particles like radon, thoron and their alpha-decaying daughters by means of a diffusion chamber with a passive detector, preferably with a solid state track detector. In the chamber above and towards the detector there is a single metallized electret with negative polarity. The distance between electret and detector corresponds to the range of the alpha particles of radon daughters in air at the most. The electret collects the positively charged daughters and functions as surface source. The electret increases the sensitivity by the factor 4

  2. Multispecimen dual-beam irradiation damage chamber

    International Nuclear Information System (INIS)

    Packan, N.H.; Buhl, R.A.

    1980-06-01

    An irradiation damage chamber that can be used to rapidly simulate fast neutron damage in fission or fusion materials has been designed and constructed. The chamber operates in conjunction with dual Van de Graaff accelerators at ORNL to simulate a wide range of irradiation conditions, including pulsed irradiation. Up to six experiments, each with up to nine 3-mm disk specimens, can be loaded into the ultrahigh vacuum chamber. Specimen holders are heated with individual electron guns, and the temperature of each specimen can be monitored during bombardment by an infrared pyrometer. Three different dose levels may be obtained during any single bombardment, and the heavy-ion flux on each of the nine specimens can be measured independently with only a brief interruption of the beam. The chamber has been in service for nearly three years, during which time approximately 250 bombardments have been successfully carried out. An appendix contains detailed procedures for operating the chamber

  3. Bi-cone vacuum chamber in the ISR

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    The "bi-cone" vacuum chamber in ISR intersection I-7, for experiment R702. Made from 0.28 mm thick titanium, it was at its time the most transparent chamber ever built. Ian Wilson is standing next to the chamber. See also 7609219.

  4. Device for gamma-chamber transducer alignment

    International Nuclear Information System (INIS)

    Mirkhodzhaev, A.Kh.; Kuznetsov, N.K.; Ostryj, Yu.E.

    1987-01-01

    The device consists of the upper part of the gamma chamber pilar to which a rod is rigidly fastened with a disk of acrylic plastic moving freely on the opposite end. The disk is placed coaxially and is equal to the gamma chamber detector crystal. The device makes it possible to use ordinary medical couches covered with a porolone mattress when the gamma chamber detector is placed below

  5. Bubble chamber: Omega production and decay

    CERN Document Server

    1973-01-01

    This image is taken from one of CERN's bubble chambers and shows the decay of a positive kaon in flight. The decay products of this kaon can be seen spiraling in the magnetic field of the chamber. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that has been heated to boiling point.

  6. Venturi vacuum systems for hypobaric chamber operations.

    Science.gov (United States)

    Robinson, R; Swaby, G; Sutton, T; Fife, C; Powell, M; Butler, B D

    1997-11-01

    Physiological studies of the effects of high altitude on man often require the use of a hypobaric chamber to simulate the reduced ambient pressures. Typical "altitude" chambers in use today require complex mechanical vacuum systems to evacuate the chamber air, either directly or via reservoir system. Use of these pumps adds to the cost of both chamber procurement and maintenance, and service of these pumps requires trained support personnel and regular upkeep. In this report we describe use of venturi vacuum pumps to perform the function of mechanical vacuum pumps for human and experimental altitude chamber operations. Advantages of the venturi pumps include their relatively low procurement cost, small size and light weight, ease of installation and plumbing, lack of moving parts, and independence from electrical power sources, fossil fuels and lubricants. Conversion of three hyperbaric chambers to combined hyper/hypobaric use is described.

  7. An anterior signaling center patterns and sizes the anterior neuroectoderm of the sea urchin embryo.

    Science.gov (United States)

    Range, Ryan C; Wei, Zheng

    2016-05-01

    Anterior signaling centers help specify and pattern the early anterior neuroectoderm (ANE) in many deuterostomes. In sea urchin the ANE is restricted to the anterior of the late blastula stage embryo, where it forms a simple neural territory comprising several types of neurons as well as the apical tuft. Here, we show that during early development, the sea urchin ANE territory separates into inner and outer regulatory domains that express the cardinal ANE transcriptional regulators FoxQ2 and Six3, respectively. FoxQ2 drives this patterning process, which is required to eliminate six3 expression from the inner domain and activate the expression of Dkk3 and sFRP1/5, two secreted Wnt modulators. Dkk3 and low expression levels of sFRP1/5 act additively to potentiate the Wnt/JNK signaling pathway governing the positioning of the ANE territory around the anterior pole, whereas high expression levels of sFRP1/5 antagonize Wnt/JNK signaling. sFRP1/5 and Dkk3 levels are rigidly maintained via autorepressive and cross-repressive interactions with Wnt signaling components and additional ANE transcription factors. Together, these data support a model in which FoxQ2 initiates an anterior patterning center that implements correct size and positions of ANE structures. Comparisons of functional and expression studies in sea urchin, hemichordate and chordate embryos reveal striking similarities among deuterostome ANE regulatory networks and the molecular mechanism that positions and defines ANE borders. These data strongly support the idea that the sea urchin embryo uses an ancient anterior patterning system that was present in the common ambulacrarian/chordate ancestor. © 2016. Published by The Company of Biologists Ltd.

  8. Apparatus for reading and recharging condenser ionization chambers

    International Nuclear Information System (INIS)

    McCall, R.C.

    1977-01-01

    A metering circuit for a condenser ionization chamber is disclosed for simultaneously recharging the ionization chamber and reading out the amount of charge required to recharge the chamber. During the recharging process, the amount of charge necessary to recharge the ionization chamber capacitor is placed on an integrating capacitor in the metering apparatus. The resultant voltage across the integrating capacitor is a measure of the radiation to which the ionization chamber was exposed. 9 claims, 1 figure

  9. Liquid-filled ionization chamber temperature dependence

    Energy Technology Data Exchange (ETDEWEB)

    Franco, L. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain)]. E-mail: luciaff@usc.es; Gomez, F. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Iglesias, A. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pardo, J. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pazos, A. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pena, J. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Zapata, M. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain)

    2006-05-10

    Temperature and pressure corrections of the read-out signal of ionization chambers have a crucial importance in order to perform high-precision absolute dose measurements. In the present work the temperature and pressure dependences of a sealed liquid isooctane filled ionization chamber (previously developed by the authors) for radiotherapy applications have been studied. We have analyzed the thermal response of the liquid ionization chamber in a {approx}20 deg. C interval around room temperature. The temperature dependence of the signal can be considered linear, with a slope that depends on the chamber collection electric field. For example, a relative signal slope of 0.27x10{sup -2}K{sup -1} for an operation electric field of 1.67x10{sup 6}Vm{sup -1} has been measured in our detector. On the other hand, ambient pressure dependence has been found negligible, as expected for liquid-filled chambers. The thermal dependence of the liquid ionization chamber signal can be parametrized within the Onsager theory on initial recombination. Considering that changes with temperature of the detector response are due to variations in the free ion yield, a parametrization of this dependence has been obtained. There is a good agreement between the experimental data and the theoretical model from the Onsager framework.

  10. Bubble chamber: antiproton annihilation

    CERN Multimedia

    1971-01-01

    These images show real particle tracks from the annihilation of an antiproton in the 80 cm Saclay liquid hydrogen bubble chamber. A negative kaon and a neutral kaon are produced in this process, as well as a positive pion. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that had been heated to boiling point.

  11. Atraumatic Anterior Dislocation of the Hip Joint

    Directory of Open Access Journals (Sweden)

    Tadahiko Ohtsuru

    2015-01-01

    Full Text Available Dislocation of the hip joint in adults is usually caused by high-energy trauma such as road traffic accidents or falls from heights. Posterior dislocation is observed in most cases. However, atraumatic anterior dislocation of the hip joint is extremely rare. We present a case of atraumatic anterior dislocation of the hip joint that was induced by an activity of daily living. The possible causes of this dislocation were anterior capsule insufficiency due to developmental dysplasia of the hip, posterior pelvic tilt following thoracolumbar kyphosis due to vertebral fracture, and acetabular anterior coverage changes by postural factor. Acetabular anterior coverage changes in the sagittal plane were measured using a tomosynthesis imaging system. This system was useful for elucidation of the dislocation mechanism in the present case.

  12. Temperature Studies for ATLAS MDT BOS Chambers

    CERN Document Server

    Engl, A.; Biebel, O.; Mameghani, R.; Merkl, D.; Rauscher, F.; Schaile, D.; Ströhmer, R.

    Data sets with high statistics taken at the cosmic ray facility, equipped with 3 ATLAS BOS MDT chambers, in Garching (Munich) have been used to study temperature and pressure effects on gas gain and drifttime. The deformation of a thermally expanded chamber was reconstructed using the internal RasNik alignment monitoring system and the tracks from cosmic data. For these studies a heating system was designed to increase the temperature of the middle chamber by up to 20 Kelvins over room temperature. For comparison the temperature effects on gas properties have been simulated with Garfield. The maximum drifttime decreased under temperature raise by -2.21 +- 0.08 ns/K, in agreement with the results of pressure variations and the Garfield simulation. The increased temperatures led to a linear increase of the gas gain of about 2.1% 1/K. The chamber deformation has been analyzed with the help of reconstructed tracks. By the comparison of the tracks through the reference chambers with these through the test chamber ...

  13. Do patients prefer mesh or anterior colporrhaphy for primary correction of anterior vaginal wall prolapse: a labelled discrete choice experiment

    NARCIS (Netherlands)

    Notten, K. J. B.; Essers, B. A.; Weemhoff, M.; Rutten, A. G. H.; Donners, J. J. A. E.; van Gestel, I.; Kruitwagen, R. F. M. P.; Roovers, J. P. W. R.; Dirksen, C. D.

    2015-01-01

    We investigated patients' preferences for anterior colporrhaphy or mesh surgery as surgical correction of anterior vaginal wall prolapse. Labelled discrete choice experiment. Three Dutch teaching hospitals. Women with anterior vaginal wall prolapse Pelvic Organ Prolapse Quantification stage 2 or

  14. Brookhaven National Laboratory's multiparticle spectrometer drift chamber system

    International Nuclear Information System (INIS)

    Etkin, A.; Kramer, M.A.

    1979-01-01

    A system of drift chambers is being built to replace the present spark chambers in the Brookhaven National Laboratory's Multiparticle Spectrometer. This system will handle a beam of approx. 3 million particles per second and have a resolution of 200 μm. A summary of the status of the chambers and the custom integrated circuits is presented. The data acquisition system is described. Prototype chambers have been built and tested with results that are consistent with the expected chamber properties

  15. LEP vacuum chamber, cross-section

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    Cross-section of the final prototype for the LEP vacuum chamber. The elliptic main-opening is for the beam. The small channel to the left is for the cooling water, to carry away the heat deposited by the synchrotron radiation. The square channel to the right houses the Non-Evaporable Getter (NEG) pump. The chamber is made from extruded aluminium. Its outside is clad with lead, to stop the synchrotron radiation emitted by the beam. For good adherence between Pb and Al, the Al chamber was coated with a thin layer of Ni. Ni being slightly magnetic, some resulting problems had to be overcome. See also 8301153.

  16. Anterior pseudoarthrectomy for symptomatic Bertolotti's syndrome.

    Science.gov (United States)

    Malham, Gregory M; Limb, Rebecca J; Claydon, Matthew H; Brazenor, Graeme A

    2013-12-01

    Painful L5/S1 pseudoarthrosis has been previously managed with posterior excision and/or lumbar fusion. To our knowledge, the anterior approach for L5/S1 pseudoarthrectomy in the treatment of Bertolotti's syndrome has not been described. We present two patients with severe symptomatic L5/S1 pseudoarthroses that were successfully excised via an anterior retroperitoneal approach with 2 year clinical and radiological follow-up. The literature regarding surgical treatments for Bertolotti's syndrome is reviewed. The technique for an anterior retroperitoneal approach is described. This approach has been safe and effective in providing long term symptomatic relief to our two patients. Further studies comparing the outcomes of anterior versus posterior pseudoarthrectomy will guide the management of this condition. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Note: Small anaerobic chamber for optical spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Chauvet, Adrien A. P., E-mail: adrien.chauvet@gmail.com; Chergui, Majed [Ecole Polytechnique Fédérale de Lausanne (EPFL), Laboratoire de Spectroscopie Ultrarapide, ISIC, Faculté des Sciences de Base, Station 6, 1015 Lausanne (Switzerland); Agarwal, Rachna; Cramer, William A. [Department of Biological Sciences, Purdue University, West Lafayette, Indiana 47907 (United States)

    2015-10-15

    The study of oxygen-sensitive biological samples requires an effective control of the atmosphere in which they are housed. In this aim however, no commercial anaerobic chamber is adequate to solely enclose the sample and small enough to fit in a compact spectroscopic system with which analysis can be performed. Furthermore, spectroscopic analysis requires the probe beam to pass through the whole chamber, introducing a requirement for adequate windows. In response to these challenges, we present a 1 l anaerobic chamber that is suitable for broad-band spectroscopic analysis. This chamber has the advantage of (1) providing access, via a septum, to the sample and (2) allows the sample position to be adjusted while keeping the chamber fixed and hermetic during the experiment.

  18. Structural Analysis of Extended Plasma Focus Chamber

    International Nuclear Information System (INIS)

    Mohd Azhar Ahmad; Abdul Halim Baijan; Siti Aiasah Hashim

    2016-01-01

    Accelerator Development Centre (ADC) of Nuclear Malaysia intends to upgrade the plasma focus device. It involves the extension part placed on top of the existing plasma focus vacuum chamber. This extended vacuum chamber purposely to give an extra space in conducting experiments on the existing plasma focus chamber. The aim of upgrading the plasma focus device is to solve the limitation in research and analysis of sample due to its done in an open system that cause analysis of samples is limited and less optimal. This extended chamber was design in considering the ease of fabrication as well as durability of its structural. Thus, this paper discusses the structural analysis in term of pressure loading effect in extended chamber. (author)

  19. Plasma chemistry in wire chambers

    International Nuclear Information System (INIS)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an 55 Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed

  20. Wire chamber degradation at the Argonne ZGS

    International Nuclear Information System (INIS)

    Haberichter, W.; Spinka, H.

    1986-01-01

    Experience with multiwire proportional chambers at high rates at the Argonne Zero Gradient Synchrotron is described. A buildup of silicon on the sense wires was observed where the beam passed through the chamber. Analysis of the chamber gas indicated that the density of silicon was probably less than 10 ppM

  1. Drift chamber vertex detectors for SLC/LEP

    Energy Technology Data Exchange (ETDEWEB)

    Hayes, K G

    1988-03-01

    Factors influencing the design of drift chamber vertex detectors for SLC and LEP are discussed including global strategy, chamber gas, cell design, and signal processing. The designs of the vertex chambers for the L3 and OPAL experiments at LEP and the Mark II experiment at the SLC are described.

  2. Radon-daughter chamber instrumentation system reference manual

    International Nuclear Information System (INIS)

    Showalter, R.; Johnson, L.

    1985-01-01

    The radon-daughter chamber instrumentation system collects environmental data from the radon-daughter chamber. These data are then recorded on a Tandberg system tape cartridge and transmitted to the HP-1000 computer for processing. Generators which inject radon and condensation nuclei into the chamber are also included with the instrumentation system

  3. Nuclear design considerations for Z-IFE chambers

    Energy Technology Data Exchange (ETDEWEB)

    Meier, W.R. [Lawrence Livermore National Laboratory, P.O. Box 808, L-641, Livermore, CA 94551 (United States)]. E-mail: meier5@llnl.gov; Schmitt, R.C. [Bettis Atomic Power Laboratory, Pittsburgh, PA 15203 (United States); Abbott, R.P. [Lawrence Livermore National Laboratory, P.O. Box 808, L-641, Livermore, CA 94551 (United States); Latkowski, J.F. [Lawrence Livermore National Laboratory, P.O. Box 808, L-641, Livermore, CA 94551 (United States); Reyes, S. [Lawrence Livermore National Laboratory, P.O. Box 808, L-641, Livermore, CA 94551 (United States)

    2006-02-15

    Z-pinch driven IFE (Z-IFE) requires the design of a repetitive target insertion system that allows coupling of the pulsed power to the target with adequate standoff, and a chamber that can withstand blast and radiation effects from large yield targets. The present strategy for Z-IFE is to use high yield targets ({approx}2-3 GJ/shot), low repetition rate per chamber ({approx}0.1 Hz), and 10 chambers per power plant. In this study, we propose an alternative power plant configuration that uses very high yield targets (20 GJ/shot) in a single chamber operating at 0.1 Hz. A thick-liquid-wall chamber is proposed to absorb the target emission (X-rays, debris and neutrons) and mitigate the blast effects on the chamber wall. The target is attached to the end of a conical shaped recyclable transmission line (RTL) made from a solid coolant (e.g., frozen flibe), or a material that is easily separable from the coolant (e.g., steel). The RTL/target assembly is inserted through a single opening at the top of the chamber for each shot. This study looks at the RTL material choice from a safety and environmental point of view. Materials were assessed according to waste disposal rating (WDR) and contact dose rate (CDR). Neutronics calculations, using the TART2002 Monte Carlo code from Lawrence Livermore National Laboratory (LLNL), were performed for the RTL and Z-IFE chamber, and key results reported here.

  4. The anterior interhemispheric approach: a safe and effective approach to anterior skull base lesions.

    Science.gov (United States)

    Mielke, Dorothee; Mayfrank, Lothar; Psychogios, Marios Nikos; Rohde, Veit

    2014-04-01

    Many approaches to the anterior skull base have been reported. Frequently used are the pterional, the unilateral or bilateral frontobasal, the supraorbital and the frontolateral approach. Recently, endoscopic transnasal approaches have become more popular. The benefits of each approach has to be weighted against its complications and limitations. The aim of this study was to investigate if the anterior interhemispheric approach (AIA) could be a safe and effective alternative approach to tumorous and non-tumorous lesions of the anterior skull base. We screened the operative records of all patients with an anterior skull base lesion undergoing transcranial surgery. We have used the AIA in 61 patients. These were exclusively patients with either olfactory groove meningioma (OGM) (n = 43), ethmoidal dural arteriovenous fistula (dAVF) ( n = 6) or frontobasal fractures of the anterior midline with cerebrospinal fluid (CSF) leakage ( n = 12). Patient records were evaluated concerning accessibility of the lesion, realization of surgical aims (complete tumor removal, dAVF obliteration, closure of the dural tear), and approach related complications. The use of the AIA exclusively in OGMs, ethmoidal dAVFs and midline frontobasal fractures indicated that we considered lateralized frontobasal lesions not suitable to be treated successfully. If restricted to these three pathologies, the AIA is highly effective and safe. The surgical aim (complete tumor removal, complete dAVF occlusion, no rhinorrhea) was achieved in all patients. The complication rate was 11.5 % (wound infection (n = 2; 3.2 %), contusion of the genu of the corpus callosum, subdural hygroma, epileptic seizure, anosmia and asymptomatic bleed into the tumor cavity (n = 1 each). Only the contusion of the corpus callosum was directly related to the approach (1.6 %). Olfaction, if present before surgery, was preserved in all patients, except one (1.6 %). The AIA is an effective and a safe approach

  5. "Flat-Fish" Vacuum Chamber

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    The picture shows a "Flat-Fish" vacuum chamber being prepared in the ISR workshop for testing prior to installation in the Split Field Magnet (SFM) at intersection I4. The two shells of each part were hydroformed from 0.15 mm thick inconel 718 sheet (with end parts in inconel 600 for easier manual welding to the arms) and welded toghether with two strips which were attached by means of thin stainless steel sheets to the Split Field Magnet poles in order to take the vertical component of the atmospheric pressure force. This was the thinnest vacuum chamber ever made for the ISR. Inconel material was chosen for its high elastic modulus and strenght at chamber bake-out temperature. In this picture the thin sheets transferring the vertical component of the atmosferic pressure force are attached to a support frame for testing. See also 7712182, 7712179.

  6. PWCs and drift chambers at ISABELLE

    International Nuclear Information System (INIS)

    Okuno, H.; Teramoto, Y.; Wheeler, C.D.

    1978-01-01

    Rate effects in proportional chambers and drift chambers are addressed first. The widely used high-gas-gain chambers would have impaired performance at ISABELLE data rates. Improvement can be expected with lower gas gain, and this possibility is investigated with respect to position and time resolution. Results on chamber lifetime are summarized; space-charge effects, gain saturation, and radiation hardness of electronics are considered. The resolution of drift chambers is discussed in some detail; time resolution, double pulse resolution, and momentum resolution and multiple scattering are included. The expected high multiplicity of tracks from a single event, the high event rates, and the requirement for low gas gain necessitate revision of the methods for measuring the second coordinate. Known methods of two-dimensional point localization are summarized according to spatial accuracy, electronics requirements, and multihit capability. Delay lines, charge division, and cathode strips are considered. Particle identification by means of measurement of the relativistic rise of energy loss by conventional and unconventional means was investigated. 32 references, 3 figures, 4 tables

  7. Improved climatic chamber for desiccation simulation

    Directory of Open Access Journals (Sweden)

    Lozada Catalina

    2016-01-01

    Full Text Available The climatic chamber at the Universidad de Los Andes was improved for modeling desiccation in soil layers. This chamber allows the measurement of different environmental variables. In this research, evaporation tests were conducted in water imposing boundary conditions for drying, and then these tests were performed in a soil layer. The soil was prepared from a slurry state and was drying controlling the temperature, the infrared radiation, the wind velocity, and the relative humidity. In the first part of this paper, a description of the climatic chamber, operation ranges and theoretical work principles of the climatic chamber are presented. Then, the second part shows the results for desiccation in water and soil. The desiccation tests performed with the climatic chamber allow simulating all environmental conditions accurately during drying coupling the effect of all environmental variables. As a result, the evaporation rate increases with infrared radiation in soil and water. The rate at the beginning of the desiccation tests in clays is the same as in water. However, this evaporation rate decreases as the soil becomes desiccated.

  8. Mixed field dosimetry with the twin chamber technique

    International Nuclear Information System (INIS)

    Burger, G.; Maier, E.

    1974-04-01

    For the separate dosimetry of the neutron- and gamma-component in a mixed beam it is principally possible to use two ionization chambers with different ratios of neutron- to gamma sensitivity. Several authors proposed for this purpose the use of a homogenious TE-chamber filled with the TE-gas and of a carbon-chamber filled with CO 2 -gas. This chamber combination is also commercially available in several countries. The chambers are normally equipped with a continuous gas-flow provision and with a waterproof-housing for the use within liquid phantoms. The application of such chambers for mixed field dosimetry in the intercomparison project of the ICRU at the RARAF-facility in Brookhaven (International Neutron Dosimetry Intercomparison - INDI) is described. (orig./HP) [de

  9. [Dynamics of riboflavin level in aqueous humour of anterior chamber of experimental animals under standard stroma saturation by ultraviolet corneal cross-linking solutions].

    Science.gov (United States)

    Bikbov, M M; Shevchuk, N E; Khalimov, A R; Bikbova, G M

    To evaluate the dynamics of riboflavin changes in the aqueous humour of the anterior chamber (AHAC) of rabbits' eyes during standard ultraviolet (UV) cross-linking with account to the area of corneal debridement. Forty two rabbits were studied sequentially. The following solutions of riboflavin were used for cornea saturation: IR - 0.1% isosmotic riboflavin, D - Dextralink (0.1% riboflavin with 20% dextran), R - 0.1% riboflavin with 1.0% hydroxypropylmethylcellulose (HPMC). Each solution was evaluated in 3 groups that differed in the diameter of corneal debridement: group 1 - Epi-Off 3 mm (IR-3, D-3, P-3), group 2 - Epi-Off 6 mm (IR-6, D-6, R-6), and group 3 - Epi-Off 9 mm (IR-9, D-9, R-9). Aqueous humour sampling (252 samples in total) was performed in 10-minute intervals within a 60 minute period. Riboflavin levels were measured by enzyme-linked immunoassay (ID-Vit microbiological test system; Immundiagnostik, Germany). Stable growth rates of riboflavin level in the AHAC (with maximum values reached at 30-40 min) were observed for solutions D and R, regardless of the variant of corneal debridement. Moreover, throughout the whole follow-up period and regardless of the area of corneal debridement, the solution D provided a relatively lower concentration of riboflavin in the AHAC as compared to the two other solutions. At 30 minutes, when the cornea was considered ready for UV irradiation, the riboflavin level in the AHAC ranged from 385±26.1 μg/l (D-9) to 665±28 μg/l (R-9). In groups IR-9, IR-6, P-6, IR-3, and P-3 riboflavin levels were found to be in the same range starting at 20 minutes. However, even a sufficient concentration of riboflavin in the cornea or AHAC cannot guarantee safe and effective UV cross-linking, since the removed epithelium limits the area of the stroma that can be saturated with riboflavin, while the area of UV exposure is 8-10 mm. Safe and efficient standard UV cross-linking may be performed only under sufficient saturation of the

  10. Innervation of the Anterior Sacroiliac Joint.

    Science.gov (United States)

    Cox, Marcus; Ng, Garrett; Mashriqi, Faizullah; Iwanaga, Joe; Alonso, Fernando; Tubbs, Kevin; Loukas, Marios; Oskouian, Rod J; Tubbs, R Shane

    2017-11-01

    Sacroiliac joint pain can be disabling and recalcitrant to medical therapy. The innervation of this joint is poorly understood, especially its anterior aspect. Therefore, the present cadaveric study was performed to better elucidate this anatomy. Twenty-four cadaveric sides underwent dissection of the anterior sacroiliac joint, with special attention given to any branches from regional nerves to this joint. No femoral, obturator, or lumbosacral trunk branches destined to the anterior sacroiliac joint were identified in the 24 sides. In 20 sides, one or two small branches (less than 0.5 mm in diameter) were found to arise from the L4 ventral ramus (10%), the L5 ventral ramus (80%), or simultaneously from both the L4 and L5 ventral rami (10%). The length of the branches ranged from 5 to 31 mm (mean, 14 mm). All these branches arose from the posterior part of the nerves and traveled to the anterior surface of the sacroiliac joint. No statistical significance was found between sides or sexes. An improved knowledge of the innervation of the anterior sacroiliac joint might decrease suffering in patients with chronic sacroiliac joint pain. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Drift chamber tracking with neural networks

    International Nuclear Information System (INIS)

    Lindsey, C.S.; Denby, B.; Haggerty, H.

    1992-10-01

    We discuss drift chamber tracking with a commercial log VLSI neural network chip. Voltages proportional to the drift times in a 4-layer drift chamber were presented to the Intel ETANN chip. The network was trained to provide the intercept and slope of straight tracks traversing the chamber. The outputs were recorded and later compared off line to conventional track fits. Two types of network architectures were studied. Applications of neural network tracking to high energy physics detector triggers is discussed

  12. Making MUSIC: A multiple sampling ionization chamber

    International Nuclear Information System (INIS)

    Shumard, B.; Henderson, D.J.; Rehm, K.E.; Tang, X.D.

    2007-01-01

    A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the (α, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for (α, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only (α, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. x 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the (α, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the (α, p) reaction to reach the anode segment below the reaction

  13. Making MUSIC: A multiple sampling ionization chamber

    Science.gov (United States)

    Shumard, B.; Henderson, D. J.; Rehm, K. E.; Tang, X. D.

    2007-08-01

    A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the (α, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for (α, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only (α, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. × 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the (α, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the (α, p) reaction to reach the anode segment below the reaction.

  14. Making MUSIC: A multiple sampling ionization chamber

    Energy Technology Data Exchange (ETDEWEB)

    Shumard, B. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States)]. E-mail: shumard@phy.anl.gov; Henderson, D.J. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States); Rehm, K.E. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States); Tang, X.D. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States)

    2007-08-15

    A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the ({alpha}, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for ({alpha}, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only ({alpha}, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. x 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the ({alpha}, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the ({alpha}, p) reaction to reach the anode segment below the reaction.

  15. Simple Cloud Chambers Using Gel Ice Packs

    Science.gov (United States)

    Kamata, Masahiro; Kubota, Miki

    2012-01-01

    Although cloud chambers are highly regarded as teaching aids for radiation education, school teachers have difficulty in using cloud chambers because they have to prepare dry ice or liquid nitrogen before the experiment. We developed a very simple and inexpensive cloud chamber that uses the contents of gel ice packs which can substitute for dry…

  16. An experimental propane bubble chamber

    International Nuclear Information System (INIS)

    Rogozinski, A.

    1957-01-01

    Describes a propane bubble chamber 10 cm in diameter and 5 cm deep. The body of the chamber is in stainless steel, and it has two windows of polished hardened glass. The compression and decompression of the propane are performed either through a piston in direct contact with the liquid, or by the action on the liquid, through a triple-mylar-Perbunan membrane, of a compressed gas. The general and also optimum working conditions of the chamber are described, and a few results are given concerning, in particular, the tests of the breakage-resistance of the windows and the measurements of the thermal expansion of the compressibility isotherm for the propane employed. (author) [fr

  17. Very high intensity reaction chamber design

    International Nuclear Information System (INIS)

    Devaney, J.J.

    1975-09-01

    The problem of achieving very high intensity irradiation by light in minimal regions was studied. Three types of irradiation chamber are suggested: the common laser-reaction chamber, the folded concentric or near-concentric resonator, and the asymmetric confocal resonator. In all designs the ratio of high-intensity illuminated volume to other volume is highly dependent (to the 3 / 2 power) on the power and fluence tolerances of optical elements, primarily mirrors. Optimization of energy coupling is discussed for the common cavity. For the concentric cavities, optimization for both coherent and incoherent beams is treated. Formulae and numerical examples give the size of chambers, aspect ratios, maximum pass number, image sizes, fluences, and the like. Similarly for the asymmetric confocal chamber, formulae and numerical examples for fluences, dimensions, losses, and totally contained pass numbers are given

  18. Liquid ionization chambers for LET determination

    DEFF Research Database (Denmark)

    Kaiser, Franz-Joachim; Bassler, Niels; Tölli, Heikki

    Liquid ionization chambers [1] (LICs) have have been used in the last decades as background dosemeters. Since a few years LICs are also commercially available for dosimetry and are used for measurements of dose distributions where a high spatial distribution is necessary. Also in the last decades...... a differential equation applying several simplifications and approximations leading to discrepancies between theory and experiments [3]. The theory predicts the collection efficiency as a function of the electrical field and was applied for both air filled ionization chambers and liquid filled ionization...... chambers. For liquids the LET can be roughly deduced from the collection efficiency dependency on the electrical field inside a liquid ionization chambers [4] using an extrapolation method. We solved the fundamental differential equation again presented by Jaffe numerically, but now taking into account...

  19. DORIOT CLIMATIC CHAMBERS

    Data.gov (United States)

    Federal Laboratory Consortium — The Doriot Climatic Chambers reproduce environmental conditions occurring anywhere around the world. They provide an invaluable service by significantly reducing the...

  20. Practical electron dosimetry: a comparison of different types of ionization chambers

    International Nuclear Information System (INIS)

    Dohm, O.S.; Christ, G.

    2002-01-01

    Since Markus chambers are no longer recommended in the 1997 DIN 6800-2 version there are uncertainties as to the use of alternative chamber types for electron dosimetry. Therefore, we performed a comparison between different types of ionization chambers. In particular, the widespread Farmer and Roos chambers were compared with the Markus chamber for polarity effect, chamber-to-chamber variation, and deviations of the measured absorbed dose relative to the value obtained with the Roos chamber (which is regarded as an ideal Bragg-Gray-chamber). The perturbation correction factor at 60 Co radiation was determined experimentally as 1,029 ± 0,5% (Roos chamber) and 1,018 ± 0,5% (Markus chamber) for the investigated plane-parallel chambers. In addition, we could show that the Roos chambers do not have a larger chamber-to-chamber variation than the Farmer chambers. Likewise, our results suggest that Farmer chambers could be used for electron energies above 6 MeV. (orig.) [de

  1. Sensitivity of gaseous xenon ionisation chambers (1961)

    International Nuclear Information System (INIS)

    Schuhl, C.

    1960-01-01

    It seems advantageous to fill an ionization chamber with xenon gas when this chamber is used for measuring a low intensity and high energy electron or positron beam, or monitoring a gamma beam. In the study of 5 to 50 MeV electrons, xenon allows for the ionization chamber yield, an improvement of a factor 4,5. (author) [fr

  2. Ionization chamber correction factors for MR-linacs.

    Science.gov (United States)

    Pojtinger, Stefan; Dohm, Oliver Steffen; Kapsch, Ralf-Peter; Thorwarth, Daniela

    2018-06-07

    Previously, readings of air-filled ionization chambers have been described as being influenced by magnetic fields. To use these chambers for dosimetry in magnetic resonance guided radiotherapy (MRgRT), this effect must be taken into account by introducing a correction factor k B . The purpose of this study is to systematically investigate k B for a typical reference setup for commercially available ionization chambers with different magnetic field strengths. The Monte Carlo simulation tool EGSnrc was used to simulate eight commercially available ionization chambers in magnetic fields whose magnetic flux density was in the range of 0-2.5 T. To validate the simulation, the influence of the magnetic field was experimentally determined for a PTW30013 Farmer-type chamber for magnetic flux densities between 0 and 1.425 T. Changes in the detector response of up to 8% depending on the magnetic flux density, on the chamber geometry and on the chamber orientation were obtained. In the experimental setup, a maximum deviation of less than 2% was observed when comparing measured values with simulated values. Dedicated values for two MR-linac systems (ViewRay MRIdian, ViewRay Inc, Cleveland, United States, 0.35 T/ 6 MV and Elekta Unity, Elekta AB, Stockholm, Sweden, 1.5 T/7 MV) were determined for future use in reference dosimetry. Simulated values for thimble-type chambers are in good agreement with experiments as well as with the results of previous publications. After further experimental validation, the results can be considered for definition of standard protocols for purposes of reference dosimetry in MRgRT.

  3. Ionization chamber correction factors for MR-linacs

    Science.gov (United States)

    Pojtinger, Stefan; Steffen Dohm, Oliver; Kapsch, Ralf-Peter; Thorwarth, Daniela

    2018-06-01

    Previously, readings of air-filled ionization chambers have been described as being influenced by magnetic fields. To use these chambers for dosimetry in magnetic resonance guided radiotherapy (MRgRT), this effect must be taken into account by introducing a correction factor k B. The purpose of this study is to systematically investigate k B for a typical reference setup for commercially available ionization chambers with different magnetic field strengths. The Monte Carlo simulation tool EGSnrc was used to simulate eight commercially available ionization chambers in magnetic fields whose magnetic flux density was in the range of 0–2.5 T. To validate the simulation, the influence of the magnetic field was experimentally determined for a PTW30013 Farmer-type chamber for magnetic flux densities between 0 and 1.425 T. Changes in the detector response of up to 8% depending on the magnetic flux density, on the chamber geometry and on the chamber orientation were obtained. In the experimental setup, a maximum deviation of less than 2% was observed when comparing measured values with simulated values. Dedicated values for two MR-linac systems (ViewRay MRIdian, ViewRay Inc, Cleveland, United States, 0.35 T/ 6 MV and Elekta Unity, Elekta AB, Stockholm, Sweden, 1.5 T/7 MV) were determined for future use in reference dosimetry. Simulated values for thimble-type chambers are in good agreement with experiments as well as with the results of previous publications. After further experimental validation, the results can be considered for definition of standard protocols for purposes of reference dosimetry in MRgRT.

  4. Anterior, posterior, left anterior oblique, and geometric mean views in gastric emptying studies using a glucose solution

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, W.T. [Dept. of Radiology, Univ. of Texas Health Science Center, San Antonio, TX (United States); McMahan, C.A. [Dept. of Pathology, Univ. of Texas Health Science Center, San Antonio, TX (United States); Lasher, J.C. [Dept. of Radiology, Univ. of Texas Health Science Center, San Antonio, TX (United States); Blumhardt, M.R. [Dept. of Pathology, Univ. of Texas Health Science Center, San Antonio, TX (United States); Schwartz, J.G. [Dept. of Pathology, Univ. of Texas Health Science Center, San Antonio, TX (United States)

    1995-02-01

    Previous research has shown that the single anterior view of the stomach overestimates the gastric half-emptying time of a solid meal compared to the geometric mean of the anterior and posterior views. Little research has been performed comparing the various views of gastric emptying of a glucose solution. After an overnight fast, 49 nondiabetic subjects were given a 450 ml solution containing 50 g of glucose and 200 {mu}Ci of technetium-99m sulfur colloid. Sequential 1-min anterior, posterior, and left anterior oblique views were obtained every 15 min. The mean percent solution remaining in the stomach for all three views differed from the geometric mean by 1.9% or less at all time points. Average gastric half-emptying times were: geometric mean, 62.7{+-}3.3 min; anterior, 61.9{+-}3.2 min; posterior, 63.5{+-}3.5 min; and left anterior oblique, 61.6{+-}3.3 min. These half-emptying times were not statistically different. For individual patients, differences between all three views and the geometric mean were not clinically important. Approximately 95% of all patients are expected to have gastric half-emptying times measured by any of the three single views within 17 min of the gastric half-emptying time obtained using the geometric mean. The imaging of gastric emptying using glucose solutions can be performed using a convenient single view which allows continuous dynamic imaging. (orig.)

  5. Bubble chamber: Omega production and decay

    CERN Multimedia

    1973-01-01

    This image is of real particle tracks taken from the CERN 2 m liquid hydrogen bubble chamber and shows the production and decay of a negative omega particle. A negative kaon enters the chamber which decays into many particles, including a negative omega that travels a short distance before decaying into more particles. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that had been heated to boiling point.

  6. Evaluation of carbon dioxide dissipation within a euthanasia chamber.

    Science.gov (United States)

    Djoufack-Momo, Shelly M; Amparan, Ashlee A; Grunden, Beverly; Boivin, Gregory P-

    2014-07-01

    CO₂ euthanasia is used widely for small laboratory animals, such as rodents. A common necessity in many animal research facilities is to euthanize mice in sequential batches. We assessed the effects of several variables on the time it took for CO₂ to dissipate within a chamber. Using standard euthanasia time, changes in flow rate were compared between a slow 15% fill rate for 7 min, and a slow 15% followed by a rapid 50% filling for a total of 5 min. Additional variables assessed included the effects of opening the lid after the completion of chamber filling, turning the chamber over after completion of filling, and the use and removal of a cage from within the chamber. For all trials, CO₂ levels in the chambers peaked between 50% and 80%. After the gas was turned off, the concentration of CO₂ dropped to below 10% COv within 2 min, except when the lid was left on the chamber, where concentration levels remained above 10% after 20 min. CO₂ dissipation was significantly faster when the chamber was turned upside down after filling. Significant interaction effects occurred among the factors of cage presence within the chamber, flow rate, and chamber position. Only leaving the lid on the chamber had any practical implication for delaying CO₂ dissipation. We recommend that users allow 2 min for CO₂ to clear from the chamber before subsequent euthanasia procedures, unless the chamber is manipulated to increase the dissipation rate.

  7. D0 central tracking chamber performance studies

    International Nuclear Information System (INIS)

    Pizzuto, D.

    1991-12-01

    The performance of the completed DO central tracking chamber was studied using cosmic rays at the State University of New York at Stony Brook. Also studied was a prototype tracking chamber identical in design to the completed DO tracking chamber. The prototype chamber was exposed to a collimated beam of 150 GeV pions at the Fermilab NWA test facility. Results indicate an RΦ tracking resolution compatible with the limitations imposed by physical considerations, excellent 2 track resolution, and a high track reconstruction efficiency along with a good rejection power against γ → e + e - events

  8. Argus drift chamber

    Energy Technology Data Exchange (ETDEWEB)

    Danilov, M; Nagovizin, V; Hasemann, H; Michel, E; Schmidt-Parzefall, W; Wurth, R; Kim, P

    1983-11-15

    The ARGUS detector came into operation at the DORIS-II e/sup +/s/sup -/ storage ring at the end of 1982. Its two meter long drift chamber contains 5940 sense and 24588 field wires organized in uniform 18x18.8 mm/sup 2/ drift cells filling the whole volume. These cells form 36 layers, 18 of which provide stereo views. Each sense wire is equipped with a single hit TDC and ADC for coordinate and dE/dx measurements. The chamber is operated with propane to improve momentum and dE/dx resolution. The drift chamber design and initial performance are presented. With a very crude space-time relation approximation and without all the necessary corrections applied a spatial resolution of about 200 ..mu..m was obtained for half of the drift cell volume. Further corrections should improve this result. An intrinsic dE/dx resolution of 4.2% and an actual resolution of 5% were obtained for cosmic muons and also for Bhabha scattered electrons. An actual dE/dx resolution of 5.6% was obtained for pions from e/sup +/e/sup -/ annihilation data with almost no track selection. A relativistic rise of 30% was observed in good agreement with theory. The long-term stability is still to be investigated.

  9. The wide gap resistive plate chamber

    International Nuclear Information System (INIS)

    Crotty, I.; Lamas Valverde, J.; Hatzifotiadou, D.; Williams, M.C.S.; Zichichi, A.

    1995-01-01

    The resistive plate chamber (RPC) has good time and position resolution; these factors (coupled to its simple construction) make it an attractive candidate for muon trigger systems at future colliders. However, operated in spark mode, the RPC has severe rate problems that make it unusable above 10 Hz/cm 2 . We have previously published our results concerning the operation of the RPC in spark and in avalanche mode; we have shown that the rate limit can be increased to 150 Hz/cm 2 if the RPC is operated in avalanche mode. Here, we discuss the performance of chambers with 6 and 8 mm gas gaps (compared to the more usual 2 mm gap). We outline the reasons for this choice, and also discuss anode versus cathode strip readout. We have measured the efficiency versus flux, and also show that an enhanced rate limit can be obtained if only a small region of the chamber is exposed to the beam (spot illumination). Finally we have tested the performance of chambers constructed with other materials for the resistiv e plate and compare it to chambers constructed with our preferred plastic, melamine laminate. (orig.)

  10. HYLIFE-II reactor chamber design refinements

    International Nuclear Information System (INIS)

    House, P.A.

    1994-06-01

    Mechanical design features of the reactor chamber for the HYLIFE-II inertial confinement fusion power plant are presented. A combination of oscillating and steady, molten salt streams (Li 2 BeF 4 ) are used for shielding and blast protection of the chamber walls. The system is designed for a 6 Hz repetition rate. Beam path clearing, between shots, is accomplished with the oscillating flow. The mechanism for generating the oscillating streams is described. A design configuration of the vessel wall allows adequate cooling and provides extra shielding to reduce thermal stresses to tolerable levels. The bottom portion of the reactor chamber is designed to minimize splash back of the high velocity (>12 m/s) salt streams and also recover up to half of the dynamic head. Cost estimates for a 1 GWe and 2 GWe reactor chamber are presented

  11. Results of Posterior Chamber Lens Implantation for Correction of Myopia

    Directory of Open Access Journals (Sweden)

    Pınar Sorgun Evcili

    2012-10-01

    Full Text Available Pur po se: To evaluate the results of posterior chamber phakic intraocular lens implantation in myopic patients. Ma te ri al and Met hod: Posterior chamber phakic intraocular lens (STAAR ICL implantation was performed in 58 eyes of 33 patients with mean spherical equivalent of -13.12±5.31 diopters (D (-2.5 - -24.75 D between August 2007 and October 2010 at Dr. Lütfi Kırdar Kartal Training and Research Hospital, Second Eye Clinic. The mean age of the patients was 32.84 ± 9.95 years (18-55 years - 24 (72.7% were male and 9 (27.3% were female. The study was designed as prospective case series. The patients were evaluated regarding visual acuity, refraction, endothelial cell count, and complications in postoperative period. Re sults: The mean follow-up time was 21.5±4.9 (12-24 months months. The mean spherical equivalent was -1.29±1.53 D (-5.6 D - +2.60 D at the last postoperative follow-up visit. Visual acuity was better or equal to preoperative best-corrected value in 42 (72.4% of eyes at the last follow-up visit postoperatively. Mean spherical equivalent was regressed to -1.13±1.59D at 1-month and -1.39±1.53D at 24-month postoperative follow-up visit. Pupillary-block glaucoma in 1 eye (1.7%, anterior subcapsular opacification not affecting the vision in 4 eyes, and retinal detachment in 1 eye were detected at follow-up visits. Dis cus si on: ICL implantation was observed to be an effective and safe method for correction of myopia in two-year follow-up. As possible retinal complications may develop, the patients must be followed carefully during the preoperative and postoperative period. (Turk J Ophthalmol 2012; 42: 349-54

  12. Anterior capsulotomy using the CO2 laser

    Science.gov (United States)

    Barak, Adiel; Ma-Naim, Tova; Rosner, Mordechai; Eyal, Ophir; Belkin, Michael

    1998-06-01

    Continuous circular capsulorhexis (CCC) is the preferred technique for removal of the anterior capsule during cataract surgery due to this technique assuring accurate centration of the intraocular lens. During modern cataract surgery, especially with small or foldable intra ocular lenses, centration of the lens is obligatory. Radial tears at the margin of an anterior capsulotomy may be associated with the exit of at least one loop of an intraocular lens out of the capsular bag ('pea pod' effect) and its subsequent decentration. The anterior capsule is more likely to ream intact if the continuous circular capsulorhexis (CCC) technique is used. Although manual capsulorhexis is an ideal anterior capsulectomy technique for adults, many ophthalmologists are still uncomfortable with it and find it difficult to perform, especially in complicated cases such as these done behind small pupil, cataract extraction in children and pseudoexfoliation syndrome. We have developed a technique using a CO2 laser system for safe anterior capsulotomy and tested it in animal eyes.

  13. Dilution refrigeration with multiple mixing chambers

    International Nuclear Information System (INIS)

    Coops, G.M.

    1981-01-01

    A dilution refrigerator is an instrument to reach temperatures in the mK region in a continuous way. The temperature range can be extended and the cooling power can be enlarged by adding an extra mixing chamber. In this way we obtain a double mixing chamber system. In this thesis the theory of the multiple mixing chamber is presented and tested on its validity by comparison with the measurements. Measurements on a dilution refrigerator with a circulation rate up to 2.5 mmol/s are also reported. (Auth.)

  14. MDT Commissioning Procedures Guidelines for Certifying RFI Chambers

    CERN Document Server

    Beretta, M; Branchini, P; Kourkoumelis, C; Dubbert, J; Gazis, E N; Hertenberger, R; Hurst, P; Kojine, A; Lanza, A; Marin, A; Mockett, P; Petridou, C; Tskhadadze, E G; Valente, P; Wotschack, J; Xie, Y; Zhao, Z

    2004-01-01

    Aim of the document is the definition of a common set of guidelines and test procedures for commissioning the MDT chambers. Commissioning is different for Barrel and Endcap chambers. The former will be tested at a single chamber level before going to the ATLAS pit, ready for the last quick test before final installation, while the latter will be first tested at a single chamber level (phase one), then installed into the Small and Big Wheel sectors (SW and BW), tested after the integration (phase two) and transported to the ATLAS pit for final wheel installation. The present document concerns all tests, including those of phase two for Endcap chambers, but it is possible that some specific tests, at the moment not planned, will be implemented during the Endcap phase two commissioning. It is composed of three sections: 1 â€" Guidelines for checking chamber conformity, where the main rules for declaring that chambers conform to the reference drawings and requirements are described; 2 â€" Commissioning tests,...

  15. Agreement between Gonioscopic Examination and Swept Source Fourier Domain Anterior Segment Optical Coherence Tomography Imaging

    Directory of Open Access Journals (Sweden)

    Mohammed Rigi

    2016-01-01

    Full Text Available Purpose. To evaluate interobserver, intervisit, and interinstrument agreements for gonioscopy and Fourier domain anterior segment optical coherence tomography (FD ASOCT for classifying open and narrow angle eyes. Methods. Eighty-six eyes with open or narrow anterior chamber angles were included. The superior angle was classified open or narrow by 2 of 5 glaucoma specialists using gonioscopy and imaged by FD ASOCT in the dark. The superior angle of each FD ASOCT image was graded as open or narrow by 2 masked readers. The same procedures were repeated within 6 months. Kappas for interobserver and intervisit agreements for each instrument and interinstrument agreements were calculated. Results. The mean age was 50.9 (±18.4 years. Interobserver agreements were moderate to good for both gonioscopy (0.57 and 0.69 and FD ASOCT (0.58 and 0.75. Intervisit agreements were moderate to excellent for both gonioscopy (0.53 to 0.86 and FD ASOCT (0.57 and 0.85. Interinstrument agreements were fair to good (0.34 to 0.63, with FD ASOCT classifying more angles as narrow than gonioscopy. Conclusions. Both gonioscopy and FD ASOCT examiners were internally consistent with similar interobserver and intervisit agreements for angle classification. Agreement between instruments was fair to good, with FD ASOCT classifying more angles as narrow than gonioscopy.

  16. Agreement between Gonioscopic Examination and Swept Source Fourier Domain Anterior Segment Optical Coherence Tomography Imaging

    Science.gov (United States)

    Nguyen, Donna; Minnal, Vandana R.

    2016-01-01

    Purpose. To evaluate interobserver, intervisit, and interinstrument agreements for gonioscopy and Fourier domain anterior segment optical coherence tomography (FD ASOCT) for classifying open and narrow angle eyes. Methods. Eighty-six eyes with open or narrow anterior chamber angles were included. The superior angle was classified open or narrow by 2 of 5 glaucoma specialists using gonioscopy and imaged by FD ASOCT in the dark. The superior angle of each FD ASOCT image was graded as open or narrow by 2 masked readers. The same procedures were repeated within 6 months. Kappas for interobserver and intervisit agreements for each instrument and interinstrument agreements were calculated. Results. The mean age was 50.9 (±18.4) years. Interobserver agreements were moderate to good for both gonioscopy (0.57 and 0.69) and FD ASOCT (0.58 and 0.75). Intervisit agreements were moderate to excellent for both gonioscopy (0.53 to 0.86) and FD ASOCT (0.57 and 0.85). Interinstrument agreements were fair to good (0.34 to 0.63), with FD ASOCT classifying more angles as narrow than gonioscopy. Conclusions. Both gonioscopy and FD ASOCT examiners were internally consistent with similar interobserver and intervisit agreements for angle classification. Agreement between instruments was fair to good, with FD ASOCT classifying more angles as narrow than gonioscopy. PMID:27990300

  17. Kesesuaian Hasil Pengukuran Sudut Bilik Mata Depan antara Pentacam dan Ultrasound Biomicroscopy

    Directory of Open Access Journals (Sweden)

    Maulina Zulkarnain

    2014-03-01

    Full Text Available The assessment of anterior segment, especially the examination of anterior chamber angle, plays an important role in diagnosing and managing glaucoma. Pentacam and ultrasound biomicroscopy (UBM were able to measure the anterior chamber angle quantitatively and objectively; however, UBM examination is invasive, where as Pentacam is without contact with eye globe surface. The aim of this study was to seek the conformation between Pentacam and UBM in measuring the anterior chamber angle. The study was analytic descriptive study with the agreement of both measurements in 42 eyes of 31 patients with glaucoma and non-glaucoma Cicendo Eye Hospital Bandung, in period of November to December 2010. The examination used both instruments in nasal and temporal area of anterior chamber angle with equal illumination. The agreement test using Bland and Altman and hypothesis using paired t-test. Statistically, there were no significant differences in anterior chamber open angle of nasal and temporal area between using Pentacam (37.51; 40.49; p=0.55 and UBM (38.87; 40.76; p=0.22, while the limit of agreement indicated wide range in nasal area (11.94 to -18.14 and in temporal area (11.51 to -15.31 in 95% confidence interval. In closed angle of anterior chamber, there was a significant difference at nasal and temporal area between using Pentacam (27.33; 35.65; p<0.001 and using UBM (31.47; 37.34; p<0.001, while the limit of agreement showed (4.01 to -16.65 for nasal area (2.98 to -14.73 for temporal area in 95% confidence interval. In conclusion, the measurement of the anterior chamber in open-angle group using Pentacam indicated poor agreement with using UBM; and there is no agreement in closed angle group.

  18. Aphasia following anterior cerebral artery occlusion

    International Nuclear Information System (INIS)

    Shimosaka, Shinichi; Waga, Shiro; Kojima, Tadashi; Shimizu, Takeo; Morikawa, Atsunori

    1982-01-01

    We have report two cases of aphasia that had infarcts in the distribution of the left or right anterior cerebral artery, as confirmed by computed tomography. Case 1 is a right-handed, 65-year-old man in whom computerized tomographic scanning revealed an infarction of the territory of the left anterior cerebral artery after the clipping of the anterior communicating artery aneurysm. The standard language test of aphasia (SLTA) revealed non-fluent aphasia with dysarthria, good comprehension, almost normal repetition with good articulation, and a defectiveness in writing. This syndrome was considered an instance of transcortical motor aphasia. Although three years had passed from the onset, his aphasia did not show any improvement. Case 2 is a 37-year-old man who is right-handed but who can use his left hand as well. He was admitted because of subarachnoid hemorrhage from an anterior communicating aneurysm. Because of postoperative spasm, an infarction in the distribution of the right anterior cerebral artery developed. He was totally unable to express himself vocally, but he could use written language quite well to express his ideas and had a good comprehension of spoken language. This clinical picture was considered that of an aphemia. After several weeks, his vocalization returned, but the initial output was still hypophonic. (J.P.N.)

  19. Anterior ethmoid anatomy facilitates dacryocystorhinostomy.

    Science.gov (United States)

    Blaylock, W K; Moore, C A; Linberg, J V

    1990-12-01

    The ethmoid air cell labyrinth lies adjacent to the medial orbital wall, extending even beyond the sutures of the ethmoid bone. Its anatomic relationship to the lacrimal sac fossa is important in lacrimal surgery. We evaluated computed tomographic scans of 190 orbits with normal ethmoid anatomy to define the anatomic relationship of anterior ethmoid air cells to the lacrimal sac fossa. In 93% of the orbits, the cells extended anterior to the posterior lacrimal crest, with 40% entering the frontal process of the maxilla. This anatomic relationship may be used to facilitate the osteotomy during dacryocystorhinostomy. During a 10-year period (310 cases), one of us routinely entered the anterior ethmoid air cells to initiate the osteotomy during dacryocystorhinostomy. This technique has helped to avoid lacerations of the nasal mucosa.

  20. Lifetime survivability of contaminated target-chamber optics

    International Nuclear Information System (INIS)

    Rainer, F.; Anderson, A.; Burnham, A.; Milam, D.; Turner, R.

    1996-11-01

    Target chambers used for Inertial Confinement Fusion (ICF) expose laser optics to a very hostile environment, not only from high-fluence laser irradiation but also x-ray irradiation and particulate debris from targets and chamber wall materials. Expendable debris shields provide the first line of defense to more costly optics upstream in the laser beam path to contaminants generated within the target chamber. However, the replacement of a large number of debris shields is also an expensive proposition so that extending their usable lifetime within the chamber is important. We have conducted tests to show that optics can both be cleaned and damaged by laser irradiation at 355 nm after being contaminated with potential chamber-wall materials such as B 4 C and Al 2 O 3 . Such optics can survive from one to hundreds of laser shots, depending on degree of contamination and laser fluence levels. Similarly, we have studied the survivability of optics that have been exposed to direct contamination from representative target materials irradiated in the target chamber. We have also studied the effects on optics that were not directly exposed to targets, yet received secondary exposure from the above directly-exposed samples

  1. Vacuum Chamber for the Booster Bending Magnets

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    To minimize eddy currents, induced by the rising magnetic field, the chamber was made from thin stainless steel of high specific electric resistance. For mechanical stength, it was corrugated in a hydro-forming process. The chamber is curved, to follow the beam's orbital path. Under vacuum, the chamber tends to staighten, the ceramic spacer along half of its length keeps it in place (see also 7402458).

  2. Construction and performance of large flash chambers

    International Nuclear Information System (INIS)

    Taylor, F.E.; Bogert, D.; Fisk, R.; Stutte, L.; Walker, J.K.; Wolfson, J.; Abolins, M.; Ernwein, J.; Owen, D.; Lyons, T.

    1979-01-01

    The construction and performance of 12' x 12' flash chambers used in a 340 ton neutrino detector under construction at Fermilab is described. The flash chambers supply digital information with a spatial resolution of 0.2'', and are used to finely sample the shower development of the reaction products of neutrino interactions. The flash chambers are easy and inexpensive to build and are electronically read out

  3. The knife-edge chamber

    International Nuclear Information System (INIS)

    Barasch, E.F.; Bowcock, T.J.V.; Drew, M.M.; Elliott, S.M.; Lee, B.; McIntyre, P.M.; Pang, Y.; Popovic, M.; Smith, D.D.

    1990-01-01

    In this paper the design for a new technology for particle track detectors is described. Using standard IC fabrication techniques, a pattern of microscopic knife edges and field-shaping electrodes can be fabricated on a silicon substrate. The knife-edge chamber uniquely offers attractive performance for the track chambers required for SSC detectors, for which no present technology is yet satisfactory. Its features include: excellent radiation hardness (10 Mrad), excellent spatial resolution (∼20 μm), short drift time (20 ns), and large pulse height (1 mV)

  4. Multiple chamber ionization detector

    International Nuclear Information System (INIS)

    Solomon, E.E.

    1982-01-01

    An ionization smoke detector employs a single radiation source in a construction comprising at least two chambers with a center or node electrode. The radioactive source is associated with this central electrode, and its positioning may be adjusted relative to the electrode to alter the proportion of the source that protrudes into each chamber. The source may also be mounted in the plane of the central electrode, and positioned relative to the center of the electrode. The central electrode or source may be made tiltable relative to the body of the detector

  5. Ionization chamber gradient effects in nonstandard beam configurations

    International Nuclear Information System (INIS)

    Bouchard, Hugo; Seuntjens, Jan; Carrier, Jean-Francois; Kawrakow, Iwan

    2009-01-01

    Purpose: For the purpose of nonstandard beam reference dosimetry, the current concept of reporting absorbed dose at a point in water located at a representative position in the chamber volume is investigated in detail. As new nonstandard beam reference dosimetry protocols are under development, an evaluation of the role played by the definition of point of measurement could lead to conceptual improvements prior to establishing measurement procedures. Methods: The present study uses the current definition of reporting absorbed dose to calculate ionization chamber perturbation factors for two cylindrical chamber models (Exradin A12 and A14) using the Monte Carlo method. The EGSnrc based user-code EGS lowbar chamber is used to calculate chamber dose responses of 14 IMRT beams chosen to cause considerable dose gradients over the chamber volume as previously used by Bouchard and Seuntjens [''Ionization chamber-based reference dosimetry of intensity modulated radiation beams,'' Med. Phys. 31(9), 2454-5465 (2004)]. Results: The study shows conclusively the relative importance of each physical effect involved in the nonstandard beam correction factors of 14 IMRT beams. Of all correction factors involved in the dosimetry of the beams studied, the gradient perturbation correction factor has the highest magnitude, on average, 11% higher compared to reference conditions for the Exradin A12 chamber and about 5% higher for the Extradin A14 chamber. Other perturbation correction factors (i.e., P wall , P stem , and P cel ) are, on average, less than 0.8% different from reference conditions for the chambers and beams studied. The current approach of reporting measured absorbed dose at a point in water coinciding with the location of the centroid of the chamber is the main factor responsible for large correction factors in nonstandard beam deliveries (e.g., intensity modulated radiation therapy) reported in literature. Conclusions: To reduce or eliminate the magnitude of

  6. 21 CFR 866.2120 - Anaerobic chamber.

    Science.gov (United States)

    2010-04-01

    ... and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2120 Anaerobic chamber. (a) Identification. An anaerobic chamber is a device intended for medical purposes to maintain an anaerobic (oxygen...

  7. A small flat fission chamber

    International Nuclear Information System (INIS)

    Li Yijun; Wang Dalun; Chen Suhe

    1999-01-01

    With fission materials of depleted uranium, natural uranium, enriched uranium, 239 Pu, and 237 Np, the authors have designed and made a series of small flat fission chamber. The authors narrated the construction of the fission chamber and its technological process of manufacture, and furthermore, the authors have measured and discussed the follow correct factor, self-absorption, boundary effect, threshold loss factor, bottom scatter and or so

  8. Lifetime tests for MAC vertex chamber

    International Nuclear Information System (INIS)

    Nelson, H.

    1986-01-01

    A vertex chamber for MAC was proposed in fall 1983 to increase precision in the measurement of the B hadron and tau lepton lifetimes. The chamber had to be placed within the existing central drift chamber, making access for repairs difficult and costly. Therefore for detector elements thin-walled aluminized mylar drift tubes (straws) were used because of their simplicity and robustness. The diameter of the drift tubes was 6.9 mm. The radial extent of the proposed chamber was from 3 cm to 10 cm, the inner wall of the central drift. It was clear that radiation levels, from synchrotron x-rays and overfocussed electrons, were potentially high. Since the drift distance is short in the straws, it was desirable to operate them at the highest possible gas gain, to achieve the best spatial resolution. There was a likelihood of drawing large currents in the chamber and thus causing radiation damage. Therefore a study of radiation hardness under the conditions of their proposed design was undertaken. In tests, argon-hydrocarbon mixtures consistently became unusable at ∼0.05 C/cm collected charge, due to anode buildup. Argon-CO 2 mixtures, while underquenched, were operational to 0.25 C/cm, at which point loss of cathode material became intolerable. Argon-xenon-CO 2 proved to be quenched as well as argon-hydrocarbons, but was limited by cathode damage. The MAC vertex chamber has operated at a distance of 4.6 cm from the e + e - interaction point at PEP for two years and has shown no aging effects

  9. Acoustic-Levitation Chamber

    Science.gov (United States)

    Barmatz, M. B.; Granett, D.; Lee, M. C.

    1984-01-01

    Uncontaminated environments for highly-pure material processing provided within completely sealed levitation chamber that suspends particles by acoustic excitation. Technique ideally suited for material processing in low gravity environment of space.

  10. Winging of scapula due to serratus anterior tear

    Directory of Open Access Journals (Sweden)

    Varun Singh Kumar

    2014-10-01

    Full Text Available 【Abstract】Winging of scapula occurs most commonly due to injury to long thoracic nerve supplying serratus anterior muscle. Traumatic injury to serratus anterior muscle itself is very rare. We reported a case of traumatic winging of scapula due to tear of serratus anterior muscle in a 19-year-old male. Winging was present in neutral position and in extension of right shoulder joint but not on "push on wall" test. Patient was managed conservatively and achieved satisfactory result. Key words: Serratus anterior tear; Scapula; Wounds and injuries

  11. Comparison of anterior segment measurements using Sirius Topographer® and Nidek Axial Length-Scan® with assessing repeatability in patients with cataracts

    Directory of Open Access Journals (Sweden)

    Resat Duman

    2018-01-01

    Full Text Available Purpose: The purpose of this study is to evaluate anterior segment measurements obtained using CSO Sirius Topographer® (CSO, Firenze, Italy and Nidek Axial Length (AL-Scan® (Nidek CO., Gamagori, Japan. Methods: A total of 43 eyes of 43 patients were included in this prospective study. The central corneal thickness (CCT, anterior chamber depth (ACD, white-to-white distance (WTW, flat keratometry (K1, steep keratometry (K2, and mean keratometry (K values were randomly measured three times with each device by the same examiner. The intraclass correlation coefficient of repeatability was analyzed. The compatibility of both devices was evaluated using the 95% limits of the agreement proposed by Bland and Altman. Results: Examiner achieved high repeatability for all parameters on each device except the WTW measured by Sirius. All measurements except WTW and K1 taken with the Sirius were higher than that taken with the Nidek AL-Scan®. The difference in CCT, ACD, and WTW values was statistically significant. Conclusion: High repeatability of the measurements was achieved on both devices. Although Km, K1, and K2 measurements of the Sirius and the AL-Scan® showed good agreement, WTW, CCT, and ACD measurements significantly differed between two devices. Thus, anterior segment measurements except for Km, K1, and K2 cannot be used interchangeably between Sirius and Nidek AL-Scan® devices.

  12. Polarity effects and apparent ion recombination in microionization chambers

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Jessica R., E-mail: miller@humonc.wisc.edu [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 and Department of Human Oncology, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Hooten, Brian D. [Standard Imaging, Middleton, Wisconsin 53562 (United States); Micka, John A.; DeWerd, Larry A. [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States)

    2016-05-15

    Purpose: Microchambers demonstrate anomalous voltage-dependent polarity effects. Existing polarity and ion recombination correction factors do not account for these effects. As a result, many commercial microchamber models do not meet the specification of a reference-class ionization chamber as defined by the American Association of Physicists in Medicine. The purpose of this investigation is to determine the cause of these voltage-dependent polarity effects. Methods: A series of microchamber prototypes were produced to isolate the source of the voltage-dependent polarity effects. Parameters including ionization-chamber collecting-volume size, stem and cable irradiation, chamber assembly, contaminants, high-Z materials, and individual chamber components were investigated. Measurements were performed with electrodes coated with graphite to isolate electrode conductivity. Chamber response was measured as the potential bias of the guard electrode was altered with respect to the collecting electrode, through the integration of additional power supplies. Ionization chamber models were also simulated using COMSOL Multiphysics software to investigate the effect of a potential difference between electrodes on electric field lines and collecting volume definition. Results: Investigations with microchamber prototypes demonstrated that the significant source of the voltage-dependent polarity effects was a potential difference between the guard and collecting electrodes of the chambers. The voltage-dependent polarity effects for each prototype were primarily isolated to either the guard or collecting electrode. Polarity effects were reduced by coating the isolated electrode with a conductive layer of graphite. Polarity effects were increased by introducing a potential difference between the electrodes. COMSOL simulations further demonstrated that for a given potential difference between electrodes, the collecting volume of the chamber changed as the applied voltage was altered

  13. Impact of Isometric Contraction of Anterior Cervical Muscles on Cervical Lordosis.

    Science.gov (United States)

    Fedorchuk, Curtis A; McCoy, Matthew; Lightstone, Douglas F; Bak, David A; Moser, Jacque; Kubricht, Brett; Packer, John; Walton, Dustin; Binongo, Jose

    2016-09-01

    This study investigates the impact of isometric contraction of anterior cervical muscles on cervical lordosis. 29 volunteers were randomly assigned to an anterior head translation (n=15) or anterior head flexion (n=14) group. Resting neutral lateral cervical x-rays were compared to x-rays of sustained isometric contraction of the anterior cervical muscles producing anterior head translation or anterior head flexion. Paired sample t-tests indicate no significant difference between pre and post anterior head translation or anterior head flexion. Analysis of variance suggests that gender and peak force were not associated with change in cervical lordosis. Chamberlain's to atlas plane line angle difference was significantly associated with cervical lordosis difference during anterior head translation (p=0.01). This study shows no evidence that hypertonicity, as seen in muscle spasms, of the muscles responsible for anterior head translation and anterior head flexion have a significant impact on cervical lordosis.

  14. Repair of isolated double-chambered right ventricle | El Kouache ...

    African Journals Online (AJOL)

    The finding of a double-chambered right ventricle (DCRV) is exceptionally rare as an isolated anomaly. It is a congenital cardiac anomaly in which the right ventricle is separated into two chambers, a proximal highpressure chamber and a distal low-pressure chamber, by anomalous muscles or fibrous tissues in the right ...

  15. Vacuum chamber 'bicone'

    CERN Multimedia

    1977-01-01

    This chamber is now in the National Museum of History and Technology, Smithsonian Institution, Washington, DC, USA, where it was exposed in an exhibit on the History of High Energy Accelerators (1977).

  16. Study on target interactions in emulsion chamber - Brasil-Japan emulsion chamber collaboration

    Science.gov (United States)

    Ballester, M.; Santos, C.; Bellandi Filho, J.; Chinellato, J. A.; Dobrigkeit, C.; Lattes, C. M. G.; Marques, A.; Menon, M. J.; Navia, C. E.; Sawayanagi, K.

    Experimental results are presented from observations of 80 target nuclear interactions where the total gamma-ray energy is greater than or equal to 20 TeV. Evidence is presented for the existence of two types of interactions; the interpretation is given on the basis of a fire-ball model. Two-story emulsion chambers exposed at Mount Chacaltaya, in Bolivia (5,220 m above sea level), are used. Gamma rays from nuclear interactions in the target layer of petroleum pitch (1/3 of the nuclear mean free path in thickness) are detected through observations of the electron showers generated by them in the lower chamber

  17. Climate chamber for environmentally controlled laboratory airflow experiments.

    Science.gov (United States)

    Even-Tzur, Nurit; Zaretsky, Uri; Grinberg, Orly; Davidovich, Tomer; Kloog, Yoel; Wolf, Michael; Elad, David

    2010-01-01

    Climate chambers have been widely used in in vitro and in vivo studies which require controlled environmental temperature and humidity conditions. This article describes a new desktop climate chamber that was developed for application of respiratory airflows on cultured nasal epithelial cells (NEC) under controlled temperature and humidity conditions. Flow experiments were performed by connecting the climate chamber to an airflow generator via a flow chamber with cultured NEC. Experiments at two controlled climate conditions, 25 degrees C and 40% relative humidity (RH) and 37 degrees C and 80%RH, were conducted to study mucin secretion from the cultures inresponse to the flow. The new climate chamber is a relatively simple and inexpensive apparatus which can easily be connected to any flow system for climate controlled flow experiments. This chamber can be easily adjusted to various in vitro experiments, as well as to clinical studies with animals or human subjects which require controlled climate conditions.

  18. Investigation of a multiwire proportional chamber

    International Nuclear Information System (INIS)

    Konijn, J.

    1976-01-01

    The article discusses some aspects of a prototype multiwire proportional chamber for electron detection located at IKO in Amsterdam, i.e. voltage, counting rates, noise and gas mixture (argon, ethylene bromide). The efficiency and performance of the chamber have been investigated and an error analysis is given

  19. Triangular tube proportional wire chamber system

    Energy Technology Data Exchange (ETDEWEB)

    Badtke, D H; Bakken, J A; Barnett, B A; Blumenfeld, B J; Chien, C Y; Madansky, L; Matthews, J A.J.; Pevsner, A; Spangler, W J [Johns Hopkins Univ., Baltimore, MD (USA); Lee, K L [California Univ., Berkeley (USA). Lawrence Berkeley Lab.

    1981-10-15

    We report on the characteristics of the proportional tube chamber system which has been constructed for muon identification in the PEP-4 experiment at SLAC. The mechanical and electrical properties of the extruded aluminum triangular tubes allow these detectors to be used as crude drift chambers.

  20. The Mark III vertex chamber and prototype test results

    International Nuclear Information System (INIS)

    Grab, C.

    1987-07-01

    A vertex chamber has been constructed for use in the Mark III experiment. The chamber is positioned inside the current main drift chamber and will be used to trigger data collection, to aid in vertex reconstruction, and to improve the momentum resolution. This paper discusses the chamber's construction and performance and tests of the prototype

  1. The OPAL vertex drift chamber

    International Nuclear Information System (INIS)

    Carter, J.R.; Elcombe, P.A.; Hill, J.C.; Roach, C.M.; Armitage, J.C.; Carnegie, R.K.; Estabrooks, P.; Hemingway, R.; Karlen, D.; McPherson, A.; Pinfold, J.; Roney, J.M.; Routenburg, P.; Waterhouse, J.; Hargrove, C.K.; Klem, D.; Oakham, F.G.; Carter, A.A.; Jones, R.W.L.; Lasota, M.M.B.; Lloyd, S.L.; Pritchard, T.W.; Wyatt, T.R.

    1990-01-01

    A high precision vertex drift chamber has been installed in the OPAL experiment at LEP. The design of the chamber and the associated readout electronics is described. The performance of the system has been studied using cosmic ray muons and the results of these studies are presented. A space resolution of 50 μm in the drift direction is obtained using the OPAL central detector gas mixture at 4 bar. (orig.)

  2. Chamber for Aerosol Deposition of Bioparticles

    Science.gov (United States)

    Kern, Roger; Kirschner, Larry

    2008-01-01

    Laboratory apparatus is depicted that is a chamber for aerosol deposition of bioparticles on surfaces of test coupons. It is designed for primary use in inoculating both flat and three-dimensional objects with approximately reproducible, uniform dispersions of bacterial spores of the genus Bacillus so that the objects could be used as standards for removal of the spores by quantitative surface sampling and/or cleaning processes. The apparatus is also designed for deposition of particles other than bacterial spores, including fungal spores, viruses, bacteriophages, and standard micron-sized beads. The novelty of the apparatus lies in the combination of a controllable nebulization system with a settling chamber large enough to contain a significant number of test coupons. Several companies market other nebulizer systems, but none are known to include chambers for deposition of bioparticles to mimic the natural fallout of bioparticles. The nebulization system is an expanded and improved version of commercially available aerosol generators that include nebulizers and drying columns. In comparison with a typical commercial aerosol generator, this system includes additional, higher-resolution flowmeters and an additional pressure regulator. Also, unlike a typical commercial aerosol generator, it includes stopcocks for separately controlling flows of gases to the nebulizer and drying column. To maximize the degree of uniformity of dispersion of bioaerosol, the chamber is shaped as an axisymmetrical cylinder and the aerosol generator is positioned centrally within the chamber and aimed upward like a fountain. In order to minimize electric charge associated with the aerosol particles, the drying column is made of aluminum, the drying column is in direct contact with an aluminum base plate, and three equally spaced Po-210 antistatic strips are located at the exit end of the drying column. The sides and top of the chamber are made of an acrylic polymer; to prevent

  3. Construction of radon/radon daughter calibraton chamber

    International Nuclear Information System (INIS)

    Fry, J.; Gan, T.H.; Leach, V.A.; Saddlier, J.; Solomon, S.B.; Tam, K.K.; Travis, E.; Wykes, P.

    1983-01-01

    The radon/radon daughter test chamber is a copper lined room 1.65x1.75x2.75m with an effective volume of 8000 litres. The air residence time is controlled by circulating the air in the chamber through absolute filters which remove 99.9% of particulates. Radon is drawn into the chamber from a 17 μCi 226 RaCl source using the pressure differential across the blowers (<3 psi)

  4. 30 CFR 56.7807 - Flushing the combustion chamber.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Flushing the combustion chamber. 56.7807 Section 56.7807 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Rotary Jet Piercing Rotary Jet Piercing § 56.7807 Flushing the combustion chamber. The combustion chamber...

  5. Scale testing of a partially confined blast chamber

    CSIR Research Space (South Africa)

    Grundling, W

    2012-10-01

    Full Text Available in pressure readings. A scale model of the blast chamber, Emily, was constructed with the addition of a pendulum plate hanging concentrically covering 65% of the open area. PURPOSE OF SCALED BLAST CHAMBER The purpose of this particular test is to evaluate... PHASE Illustrated in Figure 3 and 4 are the results obtained during testing of the scaled blast chamber. In both cases the pressure dissipates over time, showing pulsating behaviour as the shockwaves reflect off the chamber walls. By looking...

  6. Recent developments in wire chamber tracking at SSC

    International Nuclear Information System (INIS)

    Ogren, H.

    1990-01-01

    All of the major SSC proposed detectors use wire chambers in their tracking systems. The feasibility of wire chambers in an SSC detector has now been established by a number of groups planning detectors at SSC. The major advances during the past year in understanding straw tube drift chambers are presented and several innovations in gaseous wire chambers are discussed. The R and D section will concentrate on progress in drift cell design, electronics and signal processing, and engineering aspects of the tracking designs

  7. Method of controlling weld chamber purge and cover gas atmosphere

    International Nuclear Information System (INIS)

    Yeo, D.

    1992-01-01

    A method of controlling the gas atmosphere in a welding chamber includes detecting the absence of a fuel rod from the welding chamber and, in response thereto, initiating the supplying of a flow of argon gas to the chamber to purge air therefrom. Further, the method includes detecting the entry of a fuel rod in the welding chamber and, in response thereto, terminating the supplying of the flow of argon gas to the chamber and initiating the supplying of a flow of helium gas to the chamber to purge argon gas therefrom and displace the argon gas in the chamber. Also, the method includes detecting the withdrawal of the fuel rod from the welding chamber and, in response thereto, terminating the supplying of the flow of helium gas to the chamber and initiating the supplying of argon to the chamber to purge the air therefrom. The method also includes detecting the initiation of a weld cycle and, in response thereto, momentarily supplying a flow of argon gas to the welding electrode tip for initiating the welding arc. (Author)

  8. Passive Anterior Tibial Subluxation in the Setting of Anterior Cruciate Ligament Injuries: A Comparative Analysis of Ligament-Deficient States.

    Science.gov (United States)

    McDonald, Lucas S; van der List, Jelle P; Jones, Kristofer J; Zuiderbaan, Hendrik A; Nguyen, Joseph T; Potter, Hollis G; Pearle, Andrew D

    2017-06-01

    Static anterior tibial subluxation after an anterior cruciate ligament (ACL) injury highlights the abnormal relationship between the tibia and femur in patients with ACL insufficiency, although causal factors including injuries to secondary stabilizers or the time from injury to reconstruction have not been examined. To determine static relationships between the tibia and femur in patients with various states of ACL deficiency and to identify factors associated with anterior tibial subluxation. Cross-sectional study; Level of evidence, 3. Patients treated for ACL injuries were identified from an institutional registry and assigned to 1 of 4 cohorts: intact ACL, acute ACL disruption, chronic ACL disruption, and failed ACL reconstruction (ACLR). Anterior tibial subluxation of the medial and lateral compartments relative to the femoral condyles were measured on magnetic resonance imaging (MRI), and an MRI evaluation for meniscal tears, chondral defects, and injuries to the anterolateral ligament (ALL) was performed. One hundred eighty-six ACL-insufficient knees met inclusion criteria, with 26 patients without an ACL injury utilized as a control group. In the lateral compartment, the mean anterior tibial subluxation measured 0.78 mm for the control group (n = 26), 2.81 mm for the acute ACL injury group (n = 74), 3.64 mm for the chronic ACL injury group (n = 40), and 4.91 mm for the failed ACLR group (n = 72). In the failed ACLR group, 37.5% of patients demonstrated lateral compartment anterior subluxation ≥6 mm, and 11.1% of this group had anterior subluxation of the lateral compartment ≥10 mm. Multivariate regression revealed that the presence of both medial and lateral chondral defects was associated with a mean 1.09-mm increase in subluxation of the medial compartment ( P = .013). The combination of medial and lateral meniscal tears was an independent predictor of increased lateral tibia subluxation by 1.611 mm ( P = .0022). Additionally, across all knee states

  9. Optical spark chamber

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    An optical spark chamber developed for use in the Omega spectrometer. On the left the supporting frame is exceptionally thin to allow low momentum particles to escape and be detected outside the magnetic field.

  10. The Honeycomb Strip Chamber

    International Nuclear Information System (INIS)

    Graaf, Harry van der; Buskens, Joop; Rewiersma, Paul; Koenig, Adriaan; Wijnen, Thei

    1991-06-01

    The Honeycomb Strip Chamber (HSC) is a new position sensitive detector. It consists of a stack of folded foils, forming a rigid honeycomb structure. In the centre of each hexagonal cell a wire is strung. Conducting strips on the foils, perpendicular to the wires, pick up the induced avalanche charge. Test results of a prototype show that processing the signals form three adjacent strips nearest to the track gives a spatial resolution better than 64 μm for perpendicular incident tracks. The chamber performance is only slightly affected by a magnetic field. (author). 25 refs.; 21 figs

  11. micro strip gas chamber

    CERN Multimedia

    1998-01-01

    About 16 000 Micro Strip Gas Chambers like this one will be used in the CMS tracking detector. They will measure the tracks of charged particles to a hundredth of a millimetre precision in the region near the collision point where the density of particles is very high. Each chamber is filled with a gas mixture of argon and dimethyl ether. Charged particles passing through ionise the gas, knocking out electrons which are collected on the aluminium strips visible under the microscope. Such detectors are being used in radiography. They give higher resolution imaging and reduce the required dose of radiation.

  12. Simulated Field Trials Using an Indoor Aerosol Test Chamber

    National Research Council Canada - National Science Library

    Semler, D. D; Roth, A. P; Semler, K. A; Nolan, P. M

    2004-01-01

    .... In this method, the aerosol chamber control software manipulates circulation fan speeds, chamber vacuum and agent spray times to produce a simulated dynamic cloud within the aerosol test chamber...

  13. Simulated Field Trials Using An Indoor Aerosol Test Chamber

    National Research Council Canada - National Science Library

    Semler, D. D; Roth, A. P; Semler, K. A; Nolan, P. M

    2004-01-01

    .... In this method, the aerosol chamber control software manipulates circulation fan speeds, chamber vacuum and agent spray times to produce a simulated dynamic cloud within the aerosol test chamber...

  14. Equipment for handling ionization chamber

    International Nuclear Information System (INIS)

    Altmann, J.

    1988-01-01

    The device consists of an ionization channel with an ionization chamber, of a support ring, axial and radial bearings, a sleeve, a screw gear and an electric motor. The ionization chamber is freely placed on the bottom of the ionization channel. The bottom part of the channel deviates from the vertical axis. The support ring propped against the axial bearing in the sleeve is firmly fixed to the top part of the ionization channel. The sleeve is fixed to the reactor lid. Its bottom part is provided with a recess for the radial bearing which is propped against a screw wheel firmly connected to the ionization channel. In measuring neutron flux, the screw wheel is rotated by the motor, thus rotating the whole ionization channel such that the ionization chamber is displaced into the reactor core.(J.B.). 1 fig

  15. Weld Development for Aluminum Fission Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Cross, Carl Edward [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Martinez, Jesse Norris [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-16

    The Sigma welding team was approached to help fabricate a small fission chamber (roughly ½ inch dia. x ½ inch tall cylinder). These chambers are used as radiation sensors that contain small traces of radionuclides (Cf 252, U 235, and U 238) that serve to ionize gas atoms in addition to external radiation. When a voltage is applied within the chamber, the resulting ion flow can be calibrated and monitored. Aluminum has the advantage of not forming radioactive compounds when exposed to high external radiation (except from minor Na alloy content). Since aluminum has not been used before in this application, this presented an unexplored challenge.

  16. BEBC Big European Bubble Chamber

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    A view of the dismantling of the magnet of BEBC, the 3.7 m European Bubble Chamber : iron magnetic shielding ; lower and upper parts of the vacuum enclosure of the magnet; turbo-molecular vacuum pumps for the "fish-eye" windows; the two superconducting coils; a handling platform; the two cryostats suspended from the bar of the travelling crane which has a 170 ton carrying capacity. The chamber proper, not dismantled, is inside the shielding.

  17. Results from the MAC Vertex chamber

    International Nuclear Information System (INIS)

    Nelson, H.N.

    1987-05-01

    The design, construction, and performance characteristics of a high precision gaseous drift chamber made of thin walled proportional tubes are described. The device achieved an average spatial resolution of 45 μm in use for physics analysis with the MAC detector. The B-lifetime result obtained with this chamber is discussed

  18. Measurement and Compensation of BPM Chamber Motion in HLS

    Science.gov (United States)

    Li, J. W.; Sun, B. G.; Cao, Y.; Xu, H. L.; Lu, P.; Li, C.; Xuan, K.; Wang, J. G.

    2010-06-01

    Significant horizontal drifts in the beam orbit in the storage ring of HLS (Hefei Light Source) have been seen for many years. What leads to the motion of Beam Position Monitor (BPM) chamber is thermal expansion mainly caused by the synchrotron light. To monitor the BPM chamber motions for all BPMs, a BPM chamber motion measurement system is built in real-time. The raster gauges are used to measure the displacements. The results distinctly show the relation between the BPM chamber motion and the beam current. To suppress the effect of BPM chamber motion, a compensation strategy is implemented at HLS. The horizontal drifts of beam orbit have been really suppressed within 20μm without the compensation of BPM chamber motion in the runtime.

  19. Measurement and Compensation of BPM Chamber Motion in HLS

    International Nuclear Information System (INIS)

    Li, J. W.; Sun, B. G.; Cao, Y.; Xu, H. L.; Lu, P.; Li, C.; Xuan, K.; Wang, J. G.

    2010-01-01

    Significant horizontal drifts in the beam orbit in the storage ring of HLS (Hefei Light Source) have been seen for many years. What leads to the motion of Beam Position Monitor (BPM) chamber is thermal expansion mainly caused by the synchrotron light. To monitor the BPM chamber motions for all BPMs, a BPM chamber motion measurement system is built in real-time. The raster gauges are used to measure the displacements. The results distinctly show the relation between the BPM chamber motion and the beam current. To suppress the effect of BPM chamber motion, a compensation strategy is implemented at HLS. The horizontal drifts of beam orbit have been really suppressed within 20μm without the compensation of BPM chamber motion in the runtime.

  20. [Magnetic resonance imaging study of effects of accommodation on human lens morphological characters].

    Science.gov (United States)

    Zheng, Sui-lian; Zhang, Ai; Shi, Jian-jing; Zhou, Yun-xin

    2013-11-05

    To evaluate the effects of accommodation on lens morphological characters. From January 2011 to June 2011, magnetic resonance images of eyes were acquired from 30 subjects aged 20 to 24 years during accommodation and at rest. The optimal images were analyzed by Autocad 2010 to obtain the total lens cross-sectional area (CSA) and CSA of anterior and posterior portions of lens, anterior chamber depth, lens thickness, lens diameter, vitreous chamber depth and axial length during accommodation and at rest. Paired-t test was performed. The anterior curvature radius (mm), posterior curvature radius (mm), CSA of anterior portion (mm(2)), CSA of posterior portion (mm(2)), total lens CSA (mm(2)) was (8.7 ± 0.8), (6.2 ± 0.5), (7.5 ± 2.1), (12.0 ± 2.6), (20 ± 4) during relaxed accommodation; anterior curvature radius (mm), posterior curvature radius (mm), CSA of anterior portion (mm(2)), CSA of posterior portion (mm(2)), total lens CSA (mm(2)) was (7.1 ± 1.3), (5.6 ± 0.5), (14.7 ± 2.9), (12.2 ± 2.1) and (27 ± 4) during accommodation. The total lens CSA (t = -11.556, P 0.05) under a statistically independent accommodative state. There was significant difference in the anterior chamber depth (t = 4.366, P 0.05) and axial length (t = 0.418, P > 0.05) under accommodative states. During accommodation, the anterior chamber depth decreases, lens thickness increases and diameter of lens decreases while anterior portions and total lens CSA increase. There are insignificant changes in posterior portions of lens CSA, vitreous chamber depth and axial length. The accommodative changes in CSA indicate that the anterior portion of lens may be related with the properties of anterior capsule and lens material, the position of zonular attachments and the location of fetal nucleus. Helmholtz theory is supported.

  1. The thin-wall tube drift chamber operating in vacuum (prototype)

    Science.gov (United States)

    Alexeev, G. D.; Glonti, L. N.; Kekelidze, V. D.; Malyshev, V. L.; Piskun, A. A.; Potrbenikov, Yu. K.; Rodionov, V. K.; Samsonov, V. A.; Tokmenin, V. V.; Shkarovskiy, S. N.

    2013-08-01

    The goal of this work was to design drift tubes and a chamber operating in vacuum, and to develop technologies for tubes independent assembly and mounting in the chamber. These design and technology were tested on the prototype. The main features of the chamber are the following: the drift tubes are made of flexible mylar film (wall thickness 36 μm, diameter 9.80 mm, length 2160 mm) using ultrasonic welding along the generatrix; the welding device and methods were developed at JINR. Drift tubes with end plugs, anode wires and spacers were completely assembled outside the chamber. "Self-centering" spacers and bushes were used for precise setting of the anode wires and tubes. The assembled tubes were sealed with O-rings in their seats in the chamber which simplified the chamber assembling. Moreover the tube assembly and the chamber manufacture can be performed independently and in parallel; this sufficiently reduces the total time of chamber manufacture and assembling, its cost and allows tubes to be tested outside the chamber. The technology of independent tube assembling is suitable for a chamber of any shape but a round chamber is preferable for operation in vacuum. Single channel amplifier-discriminator boards which are more stable against cross talks were used for testing the tubes. Independently assembled tubes were mounted into the chamber prototype and its performance characteristic measured under the vacuum conditions. The results showed that both the structure and the tubes themselves normally operate. They are suitable for making a full-scale drift chamber for vacuum.

  2. The thin-wall tube drift chamber operating in vacuum (prototype)

    International Nuclear Information System (INIS)

    Alexeev, G.D.; Glonti, L.N.; Kekelidze, V.D.; Malyshev, V.L.; Piskun, A.A.; Potrbenikov, Yu.K.; Rodionov, V.K.; Samsonov, V.A.; Tokmenin, V.V.; Shkarovskiy, S.N.

    2013-01-01

    The goal of this work was to design drift tubes and a chamber operating in vacuum, and to develop technologies for tubes independent assembly and mounting in the chamber. These design and technology were tested on the prototype. The main features of the chamber are the following: the drift tubes are made of flexible mylar film (wall thickness 36 μm, diameter 9.80 mm, length 2160 mm) using ultrasonic welding along the generatrix; the welding device and methods were developed at JINR. Drift tubes with end plugs, anode wires and spacers were completely assembled outside the chamber. “Self-centering” spacers and bushes were used for precise setting of the anode wires and tubes. The assembled tubes were sealed with O-rings in their seats in the chamber which simplified the chamber assembling. Moreover the tube assembly and the chamber manufacture can be performed independently and in parallel; this sufficiently reduces the total time of chamber manufacture and assembling, its cost and allows tubes to be tested outside the chamber. The technology of independent tube assembling is suitable for a chamber of any shape but a round chamber is preferable for operation in vacuum. Single channel amplifier-discriminator boards which are more stable against cross talks were used for testing the tubes. Independently assembled tubes were mounted into the chamber prototype and its performance characteristic measured under the vacuum conditions. The results showed that both the structure and the tubes themselves normally operate. They are suitable for making a full-scale drift chamber for vacuum

  3. The thin-wall tube drift chamber operating in vacuum (prototype)

    Energy Technology Data Exchange (ETDEWEB)

    Alexeev, G.D. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Glonti, L.N., E-mail: glonti@sunse.jinr.ru [Joint Institute for Nuclear Research, Dubna (Russian Federation); Kekelidze, V.D.; Malyshev, V.L.; Piskun, A.A.; Potrbenikov, Yu.K.; Rodionov, V.K.; Samsonov, V.A.; Tokmenin, V.V.; Shkarovskiy, S.N. [Joint Institute for Nuclear Research, Dubna (Russian Federation)

    2013-08-01

    The goal of this work was to design drift tubes and a chamber operating in vacuum, and to develop technologies for tubes independent assembly and mounting in the chamber. These design and technology were tested on the prototype. The main features of the chamber are the following: the drift tubes are made of flexible mylar film (wall thickness 36 μm, diameter 9.80 mm, length 2160 mm) using ultrasonic welding along the generatrix; the welding device and methods were developed at JINR. Drift tubes with end plugs, anode wires and spacers were completely assembled outside the chamber. “Self-centering” spacers and bushes were used for precise setting of the anode wires and tubes. The assembled tubes were sealed with O-rings in their seats in the chamber which simplified the chamber assembling. Moreover the tube assembly and the chamber manufacture can be performed independently and in parallel; this sufficiently reduces the total time of chamber manufacture and assembling, its cost and allows tubes to be tested outside the chamber. The technology of independent tube assembling is suitable for a chamber of any shape but a round chamber is preferable for operation in vacuum. Single channel amplifier-discriminator boards which are more stable against cross talks were used for testing the tubes. Independently assembled tubes were mounted into the chamber prototype and its performance characteristic measured under the vacuum conditions. The results showed that both the structure and the tubes themselves normally operate. They are suitable for making a full-scale drift chamber for vacuum.

  4. 30 CFR 57.7807 - Flushing the combustion chamber.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Flushing the combustion chamber. 57.7807... and Rotary Jet Piercing Rotary Jet Piercing-Surface Only § 57.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be...

  5. Study and analysis of drift chamber parameters

    International Nuclear Information System (INIS)

    Martinez Laso, L.

    1988-01-01

    The present work deals mainly with drift chambers. In the first chapter a summary of drift chamber properties is presented. The information has been collected from the extensive bibliography available in this field. A very simple calculation procedure of drift chamber parameters has been developed and is presented in detail in the second chapter. Some prototypes have been made following two geometries (multidrift chamber and Z-chambers). Several installations have been used for test and calibration of these prototypes. A complete description of these installations is given in the third chapter. Cosmic rays, beta particles from a Ru106 radiactive source and a test beam in the WA (West Area) of SPS at CERN have been used for experimental purposes. The analysis and the results are described for the different setups. The experimental measurements have been used to produce a complete cell parametrization (position as function of drift time) and to obtain spatial resolution values (in the range of 200-250 um). Experimental results are in good agreement with numerical calculations. (Author)

  6. Tuned Chamber Core Panel Acoustic Test Results

    Science.gov (United States)

    Schiller, Noah H.; Allen, Albert R.

    2016-01-01

    This report documents acoustic testing of tuned chamber core panels, which can be used to supplement the low-frequency performance of conventional acoustic treatment. The tuned chamber core concept incorporates low-frequency noise control directly within the primary structure and is applicable to sandwich constructions with a directional core, including corrugated-, truss-, and fluted-core designs. These types of sandwich structures have long, hollow channels (or chambers) in the core. By adding small holes through one of the facesheets, the hollow chambers can be utilized as an array of low-frequency acoustic resonators. These resonators can then be used to attenuate low-frequency noise (below 400 Hz) inside a vehicle compartment without increasing the weight or size of the structure. The results of this test program demonstrate that the tuned chamber core concept is effective when used in isolation or combined with acoustic foam treatments. Specifically, an array of acoustic resonators integrated within the core of the panels was shown to improve both the low-frequency absorption and transmission loss of the structure in targeted one-third octave bands.

  7. A plant chamber system with downstream reaction chamber to study the effects of pollution on biogenic emissions

    NARCIS (Netherlands)

    Timovsky, J.; Gankema, Paulien; Pierik, Ronald; Holzinger, Rupert

    2014-01-01

    A system of two plant chambers and a downstream reaction chamber has been set up to investigate the emission of biogenic volatile organic compounds (BVOCs) and possible effects of pollutants such as ozone. The system can be used to compare BVOC emissions from two sets of differently treated plants,

  8. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  9. RF Anechoic Chambers, Tri-Service Research Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — In collaboration with the Navy, there are 12 RF Anechoic and static free exposure chambers located at TSRL. These chambers cover the majority of the RF spectrum and...

  10. Causes and consequences of anterior pharyngeal pouch after total laryngectomy.

    Science.gov (United States)

    Anderson, S; Hogan, D; Panizza, B

    2014-07-01

    To assess the frequency of anterior pharyngeal pouch formation after total laryngectomy, and to discuss the causes and consequences of anterior pharyngeal pouch formation. A prospective, observational study of 43 patients undergoing total laryngectomy. Data collected included laryngeal defect closure type, tumour staging and demographic information. A barium swallow was performed on day 7-14 after surgery to assess for anterior pharyngeal pouch formation and fistula formation. The incidence of anterior pharyngeal pouch formation was 47 per cent. Patients who did not have an anterior pharyngeal pouch on swallow imaging assessment were less likely to develop a pharyngo-cutaneous fistula. There was no statistically significant association between laryngeal defect closure type and anterior pharyngeal pouch formation. The anterior pharyngeal pouch is a dynamic phenomenon best investigated with a fluoroscopic swallow imaging study. Its causes are multi-factorial. Absence of an anterior pharyngeal pouch appears to confer protection against pharyngo-cutaneous fistula formation, hastening commencement of adjuvant therapy and an oral diet.

  11. System of multiwire proportional chambers at the separated particle channel for the Mirabelle bubble chamber

    International Nuclear Information System (INIS)

    Bryukhanov, N.S.; Galyaev, N.A.; Kotov, V.I.; Prosin, B.V.; Romanov, Yu.A.; Khodyrev, Yu.S.

    1980-01-01

    A system of multiwire proportional chambers (MPC) operating on-line with a M-6000 computer used during tuning and monitoring of beam parameters in a separated particle channel for the Mirabelle bubble chamber is described. Peculiarities of the construction and main characteristics of two MPC versions are considered. The first version is intended for placing in a vacuum at the edges of high-frequency separator deflector, the second one - for placing outside a vacuum in ionoguide gaps. Power supply of the proportional chambers is carried out from local compact (160x95x50 mm) high-voltage sources remotely controlled from a channel panel by low voltage. A MPC position diagram in the accelerator channel, flowsheet of registering electronics for the MPC system, main circuits of high-voltage power source, analog-to-digital converter of a code and trunk amplifier are given. A graph of amplifier signal amplitude dependence on high voltage of a chamber for a different composition of a gaseous mixture is presented. It is noted that the used elements of the electronic system provide the reliable processing of data and its transmission for a great distance (approximately 400 m). It is underlined that the MPC system operation for a long time has shown its high efficiency and reliability

  12. Monte Carlo modeling of ion chamber performance using MCNP.

    Science.gov (United States)

    Wallace, J D

    2012-12-01

    Ion Chambers have a generally flat energy response with some deviations at very low (2 MeV) energies. Some improvements in the low energy response can be achieved through use of high atomic number gases, such as argon and xenon, and higher chamber pressures. This work looks at the energy response of high pressure xenon-filled ion chambers using the MCNP Monte Carlo package to develop geometric models of a commercially available high pressure ion chamber (HPIC). The use of the F6 tally as an estimator of the energy deposited in a region of interest per unit mass, and the underlying assumptions associated with its use are described. The effect of gas composition, chamber gas pressure, chamber wall thickness, and chamber holder wall thicknesses on energy response are investigated and reported. The predicted energy response curve for the HPIC was found to be similar to that reported by other investigators. These investigations indicate that improvements to flatten the overall energy response of the HPIC down to 70 keV could be achieved through use of 3 mm-thick stainless steel walls for the ion chamber.

  13. Construction of a full-length prototype of the BESIII drift chamber and on-detector test for the BESIII drift chamber electronics

    International Nuclear Information System (INIS)

    Qin Zhonghua; Wu Linghui; Liu Jianbei; Chinese Academy of Sciences, Beijing; Yan Zhikang; Hunan Univ., Changsha; Chen Yuanbo; Chen Chang; Xu Meihang; Wang Lan; Ma Xiaoyan; Jin Yan; Liu Rongguang; Tang Xiao; Zhang Guifang; Zhu Qiming; Sheng Huayi; Zhu Kejun

    2007-01-01

    A full-length prototype of the BESIII drift chamber was built. The experience gained on gas sealing, high voltage supply and front-end electronics installation should be greatly beneficial to the successful construction of the BESIII drift chamber. An on-detector test of the BESIII drift chamber electronics was carried out with the constructed prototype chamber. The noise performance, drift time and charge measurements, and electronics gains were examined specifically. The final test results indicate that the electronics have a good performance and can satisfy their design requirements. (authors)

  14. Final report for NIF chamber dynamics studies

    International Nuclear Information System (INIS)

    Burnham, A; Peterson, P F; Scott, J M

    1998-01-01

    The National Ignition Facility (NIF), a 1.8 MJ, 192 laser beam facility, will have anticipated fusion yields of up to 20 MJ from D-T pellets encased in a gold hohlraum target. The energy emitted from the target in the form of x rays, neutrons, target debris kinetic energy, and target shrapnel will be contained in a 5 m. radius spherical target chamber. various diagnostics will be stationed around the target at varying distances from the target. During each shot, the target will emit x rays that will vaporize nearby target facing surfaces including those of the diagnostics, the target positioner, and other chamber structures. This ablated vapor will be transported throughout the chamber, and will eventually condense and deposit on surfaces in the chamber, including the final optics debris shields. The research at the University of California at Berkeley relates primarily to the NIF chamber dynamics. The key design issues are the ablation of the chamber structures, transport of the vapor through the chamber and the condensation or deposition processes of those vaporized materials. An understanding of these processes is essential in developing a concept for protecting the fina optics debris shields from an excessive coating (> 10 A) of target debris and ablated material, thereby prolonging their lifetime between change-outs. At Berkeley, we have studied the physical issues of the ablation process and the effects of varying materials, the condensation process of the vaporized material, and design schemes that can lower the threat posed to the debris shields by these processes. The work or portions of the work completed this year have been published in several papers and a dissertation [l-5

  15. MIMO OTA Testing in Small Multi-Probe Anechoic Chamber Setups

    DEFF Research Database (Denmark)

    Llorente, Ines Carton; Fan, Wei; Pedersen, Gert F.

    2016-01-01

    OTA testing of MIMO capable terminals is often performed in large anechoic chambers, where planar waves impinging the test area are assumed. Furthermore, reflections from the chamber, and probe coupling are often considered negligible due to the large dimensions of the chamber. This paper...... investigates the feasibility of reducing the physical dimension of 2D multi-probe anechoic chamber setups for MIMO OTA testing, with the purpose of reducing the cost and space of the setup. In the paper, a channel emulation algorithm and chamber compensation technique are proposed for MIMO OTA testing in small...... anechoic chambers. The performance deterioration in a small anechoic chamber, i.e., with a ring radius of 0.5 m, is demonstrated via simulations....

  16. Proportional chambers and multiwire drift chambers at high rates

    International Nuclear Information System (INIS)

    Walenta, A.H.

    1977-01-01

    The high event and particle rates expected for ISABELLE intersecting storage rings raise the question whether PWC's and drift chambers, now widely in use in experiments, still can operate under such conditions. Various effects depend on the number of avalanches produced per length of wire N and the size of the avalanche Q, i.e., on the number of positive ions created in an avalanche. Therefore the important parameter for the following discussion is the product QN. The minimum Q is determined by the type and noise level of preamplifiers used. Examples are given for a typical low noise amplifier as well as for a typical integrated ''cheap'' amplifier. The rate/wire length N depends on the chamber arrangement, wire spacing, etc. In multiwire drift chambers, a single wire shows space-charge effects reducing the pulse height by 1% at a rate of N = 7 x 10 3 mm -1 sec -1 . At a rate of N approximately equal to 10 5 mm -1 sec -1 an efficiency loss of the order of 1% was noticed. The aging effect due to deposits on the anode wire can be reduced using low noise amplifiers and low gas gain to such an extent that a lifetime of about half a year at ISABELLE can be expected. The use of conventional cheap preamplifiers will result in a typical lifetime of about 30 days. Improvements are probable. The time resolution of Δt/sub r/ = 4 nsec fwhm seems adequate for event rates of 10 7 sec -1 . The memory time Δt/sub m/ greater than or equal to 100 nsec may cause serious problems for pattern recognition depending on layout and readout. The use of induced signals on cathode pads, thus reading out shorter parts of the wire, can solve the problem

  17. Track photographing in 8-m streamer chamber

    International Nuclear Information System (INIS)

    Anisimova, N.Z.; Davidenko, V.A.; Kantserov, V.A.; Rybakov, V.G.; Somov, S.V.

    1981-01-01

    A system for obtaining data from a streamer chamber intended for measuring muon polarization is described. An optical scheme for photographing of tracks in the chamber is given. The photographing process is complicated at the expense of large dimensions and module structure of the chamber as well as due to insufficient for direct photographing brightness of streamers. The system described was tested during a long time in a physical experiment. More than 100 thousand photos have been taken by its means [ru

  18. Calibration of working standard ionization chambers and dose standardization

    International Nuclear Information System (INIS)

    Abd Elmahoud, A. A. B.

    2011-01-01

    Measurements were performed for the calibration of two working standard ionization chambers in the secondary standard dosimetry laboratory of Sudan. 600 cc cylindrical former type and 1800 cc cylindrical radical radiation protection level ionization chambers were calibrated against 1000 cc spherical reference standard ionization chamber. The chamber were calibrated at X-ray narrow spectrum series with beam energies ranged from (33-116 KeV) in addition to 1''3''7''Cs beam with 662 KeV energy. The chambers 0.6 cc and 0.3 cc therapy level ionization were used for dose standardization and beam output calibrations of cobalt-60 radiotherapy machine located at the National Cancer Institute, University of Gazira. Concerning beam output measurements for 6''0''Co radiotherapy machine, dosimetric measurements were performed in accordance with the relevant per IAEA dosimetry protocols TRS-277 and TRS-398. The kinetic energy released per unit mass in air (air kerma) were obtained by multiplying the corrected electrometer reading (nC/min) by the calibration factors (Gy/n C) of the chambers from given in the calibration certificate. The uncertainty of measurements of air kerma were calculated for the all ionization chambers (combined uncertainty) the calibration factors of these ionization chambers then were calculated by comparing the reading of air kerma of secondary standard ionization chambers to than from radical and farmer chambers. The result of calibration working standard ionization chambers showed different calibration factors ranged from 0.99 to 1.52 for different radiation energies and these differences were due to chambers response and specification. The absorbed dose to to water calculated for therapy ionization chamber using two code of practice TRS-277 and TRS-398 as beam output for 6''0''Co radiotherapy machine and it can be used as a reference for future beam output calibration in radiotherapy dosimetry. The measurement of absorbed dose to water showed that the

  19. Measuring the sensitivity of a boron-lined ion chamber

    International Nuclear Information System (INIS)

    Barton, D.M.

    1992-03-01

    Boron-lined ion chambers are used to monitor external neutron flux from fissionable materials assembled at the Los Alamos Critical Assembly Experiment Facility. The sensitivity of these chambers must be measured periodically in order to detect changes in filling gas and to evaluate other factors that may affect chamber performance. We delineate a procedure to measure ion chamber response using a particular neutron source ( 239 PuBe) in a particular moderating geometry of polyethylene. We also discuss use of the amplifier, high-voltage power supply, recorders, and scram circuits that comprise the complete ion chamber monitoring system

  20. GBO RF Anechoic Chamber & Antenna Test Range

    Data.gov (United States)

    Federal Laboratory Consortium — A shielded anechoic chamber measuring 15 by 15 by 37 feet is located in the Jansky Laboratory at Green Bank. This chamber has been outfitted as a far-field antenna...

  1. Safety shield for vacuum/pressure-chamber windows

    Science.gov (United States)

    Shimansky, R. A.; Spencer, R.

    1980-01-01

    Optically-clear shatter-resistant safety shield protects workers from implosion and explosion of vacuum and pressure windows. Plastic shield is inexpensive and may be added to vacuum chambers, pressure chambers, and gas-filling systems.

  2. CLINICAL STUDY OF POSTERIOR CHAMBER PHAKIC IOL PLACEMENT IN MYOPIC PATIENTS

    Directory of Open Access Journals (Sweden)

    Ashok Kumar P

    2017-02-01

    Full Text Available BACKGROUND The aim of this study was to determine the safety and efficacy of posterior chamber phakic IOL in Myopic patients. MATERIALS AND METHODS This prospective interventional study included 50 eyes of 50 patients with myopia. Patients of age more than 18 yrs. Stable refraction, Myopia, Mild to Moderate keratoconus and absence of any ocular pathology and any history of ocular surgeries were included in this study. Prior to starting treatment certain parameters like visual acuity, AC depth, Iridocorneal Angle Aperture, Endothelial cell count, Central corneal thickness and IOP were considered. Intervention- Implantation of the phakic IOL. Main outcome Measures- Uncorrected Visual Acuity (UCVA, best spectacle corrected visual acuity (BSCVA, AS OCT AC depthbetween endothelium and phakic IOL, IOP and Endothelial cell count were recorded. RESULTS Postoperative examinations conducted at day 1, day 3, after 1 week, 1 month and after 3 months .out of 50 patients, 4 patients had striate keratopathy, 2 patients had shallow ac during immediate post-operative period. During the postoperative follow up 10 patients had BCVA of 6/9-6/6 (20%, 14 patients had 6/9-6/12 (28%, 24 patients had 6/12-6/24(48% and remaining 2 patients had <6/24 which was better than their preoperative uncorrected visual acuity. CONCLUSION Based on this prospective clinical study and on comparison with other clinical studies posterior chamber phakic IOL corrective procedures are safe and effective for treatment of myopia. It also shows that it can provide sharp and clear vision in 96% of our study population. It does not induce dry eye syndrome as in other refractive surgeries. Short term complications like endothelial damage, angle closure glaucoma, iritis, anterior capsule injury/lens changes were not encountered during our study. But still long term follow up is required to confirm long term safety of the implant.

  3. Developing Cloud Chambers with High School Students

    Science.gov (United States)

    Ishizuka, Ryo; Tan, Nobuaki; Sato, Shoma; Zeze, Syoji

    The result and outcome of the cloud chamber project, which aims to develop a cloud chamber useful for science education is reported in detail. A project includes both three high school students and a teacher as a part of Super Science High School (SSH) program in our school. We develop a dry-ice-free cloud chamber using salt and ice (or snow). Technical details of the chamber are described. We also argue how the project have affected student's cognition, motivation, academic skills and behavior. The research project has taken steps of professional researchers, i.e., in planning research, applying fund, writing a paper and giving a talk in conferences. From interviews with students, we have learnt that such style of scientific activity is very effective in promoting student's motivation for learning science.

  4. The Impedance of Multi-layer Vacuum Chambers

    CERN Document Server

    Vos, L

    2003-01-01

    Many components of the LHC vacuum chamber have multi-layered walls : the copper coated cold beam screen, the titanium coated ceramic chamber of the dump kickers, the ceramic chamber of the injection kickers coated with copper stripes, only to name a few. Theories and computer programs are available for some time already to evaluate the impedance of these elements. Nevertheless, the algorithm developed in this paper is more convenient in its application and has been used extensively in the design phase of multi-layer LHC vacuum chamber elements. It is based on classical transmission line theory. Closed expressions are derived for simple layer configurations, while beam pipes involving many layers demand a chain calculation. The algorithm has been tested with a number of published examples and was verified with experimental data as well.

  5. Hydrostatic Hyperbaric Chamber Ventilation System

    Science.gov (United States)

    Sarguisingh, Miriam J.

    2012-01-01

    The hydrostatic hyperbaric chamber (HHC) represents the merger of several technologies in development for NASA aerospace applications, harnessed to directly benefit global health. NASA has significant experience developing composite hyperbaric chambers for a variety of applications. NASA also has researched the application of water-filled vessels to increase tolerance of acceleration forces. The combination of these two applications has resulted in the hydrostatic chamber, which has been conceived as a safe, affordable means of making hyperbaric oxygen therapy (HBOT) available in the developing world for the treatment of a variety of medical conditions. Specifically, HBOT is highly-desired as a possibly curative treatment for Buruli Ulcer, an infectious condition that afflicts children in sub-Saharan Africa. HBOT is simply too expensive and too dangerous to implement in the developing world using standard equipment. The HHC technology changes the paradigm. The HHC differs from standard hyperbaric chambers in that the majority of its volume is filled with water which is pressurized by oxygen being supplied in the portion of the chamber containing the patient s head. This greatly reduces the amount of oxygen required to sustain a hyperbaric atmosphere, thereby making the system more safe and economical to operate. An effort was taken to develop an HHC system to apply HBOT to children that is simple and robust enough to support transport, assembly, maintenance and operation in developing countries. This paper details the concept for an HHC ventilation and pressurization system to provide controlled pressurization and adequate washout of carbon dioxide while the subject is enclosed in the confined space during the administration of the medical treatment. The concept took into consideration operational complexity, safety to the patient and operating personnel, and physiological considerations. The simple schematic, comprised of easily acquired commercial hardware

  6. Tratamiento ortodóncico-quirúrgico de una adaquia anterior Orthodontic-surgical treatment of anterior open bite

    Directory of Open Access Journals (Sweden)

    Anselmo López Rodríguez

    2004-08-01

    Full Text Available En la práctica y desarrollo de la cirugía ortognática en el Hospital Universitario "Comandante Manuel Fajardo" a lo largo de los años, la morbilidad de diferentes anomalías del desarrollo maxilo-mandibulares ha mostrado que la adaquia o mordida abierta anterior es bastante frecuente. Desde tempranas edades se detectan y son tratadas por el especialista en Ortodoncia. El cerrar una adaquia en ocasiones se torna difícil y es cuando el análisis del paciente debe realizarse en el grupo multidisciplianrio integrado por cirujanos maxilofaciales, ortodoncistas y protesistas. Se han detectado diferentes causas que pueden producir una adaquia y en su mayor parte son hábitos nocivos que perduran en el paciente; por ejemplo, la interferencia con el centro de crecimiento condilar, la succión del pulgar, la deglución atípica o lengua protractil, la respiración bucal, entre otras. Este trabajo está encaminado en mostrar los diferentes tratamientos que en la actualidad se emplean para reducir una mordida abierta anterior y presenta el caso de una niña de 14 años de edad portadora de una adaquia de más de 18 mm.In the context of orthognathic surgery practice and development at "Comandante Manuel Fajardo" university hospital, morbidity from several anomalies in the maxillomandibular growth has shown that anterior open bite is pretty common. Such anomalies are detected and treated by the orthodontist at early childhood. To close an anterior open bite is difficult sometimes and requires the analysis of the patient by a multidisciplinary group made up of maxillofacial surgeons, orthodontists and denture specialists. A number of causes may be the origin of anterior open bite, mainly harmful habits that persist in the patient such as interference with the condylar growth center, dummy sucking, atypical deglutition or proctatile tongue, mouth breathing, among others. This paper is aimed at showing different therapies that presently reduce anterior open

  7. Laboratory implantation for well type ionization chambers calibration

    International Nuclear Information System (INIS)

    Vianello, E.A.; Dias, D.J.; Almeida, C.E. de

    1998-01-01

    The Radiological Science Laboratory is implanting a service for calibration of well type chambers by IAEA training program. The kerma rate in the air (mu Gy/h) of the linear Cs-137 reference source CDCS-J4 have been determined using a well type chamber Standard Imaging HDR-1000 model, which have been calibrated at Secondary Standard Laboratory Calibration of IAEA, whereas two HDR-1000 Plus chambers were calibrated too, following the same standards. The results were compared with Wisconsin University calibration certification and has demonstrated that well type ionization chamber calibration can be used in brachytherapy for several kinds of radionuclides. (Author)

  8. Shock tubes: compressions in the low pressure chamber

    International Nuclear Information System (INIS)

    Schins, H.; Giuliani, S.

    1986-01-01

    The gas shock tube used in these experiments consists of a low pressure chamber and a high pressure chamber, divided by a metal-diaphragm-to-rupture. In contrast to the shock mode of operation, where incident and reflected shocks in the low pressure chamber are studied which occur within 3.5 ms, in this work the compression mode of operation was studied, whose maxima occur (in the low pressure chamber) about 9 ms after rupture. Theoretical analysis was done with the finite element computer code EURDYN-1M, where the computation was carried out to 30 ms

  9. Simple structure diffusion cloud chamber for educational purpose

    International Nuclear Information System (INIS)

    Hrehuss, Gy.; Molnar, B.

    1982-01-01

    A simple structure diffusion cloud chamber was designed and built with educational aim. The source of alpha particles is Am-241 radioisotope smeared on steel foil, the source of vapor is a felt disc saturated with methanol. Five minutes after covering the chamber the system achieves the thermodynamic equilibrium and alpha particle tracks of 5 cm length become visible in the centre of the chamber. Life-time of a track is about 0.5-1 second, the frequency is 2-3 tracks/s. The presented diffusion chamber can be built simply and easily, using cheap common materials and components. (D.Gy.)

  10. Effects of air humidity on ionization chamber response

    International Nuclear Information System (INIS)

    Meger, C.; DeLuca, P.M. Jr.; Pearson, D.W.; Venci, R.

    1983-01-01

    A study of the effect of air humidity on four different ionization chamber cap materials verified earlier studies (Kristensen and Sundbom, 1981; Mijnheer et al., 1983) and extended our understanding of the problem. We found nylon and A-150 plastic caps swell as they absorb water from the air. This accounts for as much as 2.5% increase in ionization response. Graphite chambers readily absorb and desorb water from the air. This creates a problem in maintaining dry air in a wet graphite chamber. Humid air has a different density and W value than dry air (Niatel, 1969, 1975). This decreases the charge collected in a wet graphite chamber. We observe a decrease in response of approximately 2%, a value greater than can be accounted for by these effects alone. Polyethylene chambers are unaffected by humid air. 4 refs., 9 figs

  11. Charpak hemispherical wire chamber

    CERN Multimedia

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  12. Spontaneous, late, in-the-bag intraocular lens subluxation in a patient with a previous acute angle-closure glaucoma attack.

    Science.gov (United States)

    Su, Wei-Wen; Chang, Shirley H L

    2004-08-01

    Cataract surgery was performed in a 49-year-old woman 16 months after an acute angle-closure glaucoma attack. Zonular dialysis was observed during surgery, but the intraocular lens (IOL) was implanted in the capsular bag uneventfully. At 4 1/2 months, 1 IOL loop wrapped in the bag herniated into the anterior chamber. The patient had no history of trauma. The IOL loop remained in the anterior chamber for 9 months, until the subluxated IOL spontaneously returned to its original position. Six months later, the IOL again dislocated into the anterior chamber.

  13. Cloud chamber photographs of the cosmic radiation

    CERN Document Server

    Rochester, George Dixon

    1952-01-01

    Cloud Chamber Photographs of the Cosmic Radiation focuses on cloud chamber and photographic emulsion wherein the tracks of individual subatomic particles of high energy are studied. The publication first offers information on the technical features of operation and electrons and cascade showers. Discussions focus on the relationship in time and space of counter-controlled tracks; techniques of internal control of the cloud chamber; cascade processes with artificially-produced electrons and photons; and nuclear interaction associated with an extensive shower. The manuscript then elaborates on

  14. "Flat-Fish" vacuum chamber for the ISR

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    The "Flat-Fish" vacuum chamber was a very special one for the ISR beam intersection I-4, inside the Split-Field Magnet. Technical descriptions are given with pictures 7802042 and 7712182. There were several generations of this chamber. This picture was taken during the last year of ISR operation. See also 7510230X, 7511123X, 7802039, 7802041. A flat-fish type vacuum chamber was also used at I-8, inside the Open Axial Field Magnet (OAFM, experiment 807 on large transverse momentum collision products), see 7901358.

  15. Growing and Analyzing Biofilms in Flow Chambers

    DEFF Research Database (Denmark)

    Tolker-Nielsen, Tim; Sternberg, Claus

    2011-01-01

    This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic......, and disassembly and cleaning of the system. In addition, embedding and fluorescent in situ hybridization of flow chamber–grown biofilms are addressed. Curr. Protoc. Microbiol. 21:1B.2.1-1B.2.17. © 2011 by John Wiley & Sons, Inc....

  16. Ballistic-neutralized chamber transport of intense heavy ion beams

    International Nuclear Information System (INIS)

    Rose, D.V.; Welch, D.R.; Oliver, B.V.; Clark, R.E.; Sharp, W.M.; Friedman, A.

    2001-01-01

    Two-dimensional particle-in-cell simulations of intense heavy ion beams propagating in an inertial confinement fusion (ICF) reactor chamber are presented. The ballistic-neutralized transport scheme studied uses 4 GeV Pb +1 ion beams injected into a low-density, gas-filled reactor chamber and the beam is ballistically focused onto an ICF target before entering the chamber. Charge and current neutralization of the beam is provided by the low-density background gas. The ballistic-neutralized simulations include stripping of the beam ions as the beam traverses the chamber as well as ionization of the background plasma. In addition, a series of simulations are presented that explore the charge and current neutralization of the ion beam in an evacuated chamber. For this vacuum transport mode, neutralizing electrons are only drawn from sources near the chamber entrance

  17. Perawatan Ortodontik Gigi Anterior Berjejal dengan Tulang Alveolar yang Tipis

    Directory of Open Access Journals (Sweden)

    Miesje K. Purwanegara

    2015-09-01

    Full Text Available Anterior teeth movement in orthodontic treatment is limited to labiolingual direction by very thin alveolar bone. An uncontrolled anterior tooth movement to labiolingual direction can cause alveolar bone perforation at its root segment. This case report is to remind us that alveolar bone thickness limits orthodontc tooth movement. A case of crowded anterior teeth with thin alveolar bone in malocclusion I is reported. This case is treated using adgewise orthodontic appliance. Protraction of anterior teeth is anticipated due to thin alveolar bone on the anterior surface. The conclusion is although the alveolar bone surrounding the crowded anterior teeth is thin, by controlling the movement the teeth reposition is allowed.

  18. Anterior Cruciate Ligament OsteoArthritis Score (ACLOAS)

    DEFF Research Database (Denmark)

    Roemer, Frank W; Frobell, Richard; Lohmander, Stefan

    2014-01-01

    OBJECTIVE: To develop a whole joint scoring system, the Anterior Cruciate Ligament OsteoArthritis Score (ACLOAS), for magnetic resonance imaging (MRI)-based assessment of acute anterior cruciate ligament (ACL) injury and follow-up of structural sequelae, and to assess its reliability. DESIGN...

  19. Biomechanical Measures During Landing and Postural Stability Predict Second Anterior Cruciate Ligament Injury After Anterior Cruciate Ligament Reconstruction and Return to Sport

    Science.gov (United States)

    Paterno, Mark V.; Schmitt, Laura C.; Ford, Kevin R.; Rauh, Mitchell J.; Myer, Gregory D.; Huang, Bin; Hewett, Timothy E.

    2016-01-01

    Background Athletes who return to sport participation after anterior cruciate ligament reconstruction (ACLR) have a higher risk of a second anterior cruciate ligament injury (either reinjury or contralateral injury) compared with non–anterior cruciate ligament–injured athletes. Hypotheses Prospective measures of neuromuscular control and postural stability after ACLR will predict relative increased risk for a second anterior cruciate ligament injury. Study Design Cohort study (prognosis); Level of evidence, 2. Methods Fifty-six athletes underwent a prospective biomechanical screening after ACLR using 3-dimensional motion analysis during a drop vertical jump maneuver and postural stability assessment before return to pivoting and cutting sports. After the initial test session, each subject was followed for 12 months for occurrence of a second anterior cruciate ligament injury. Lower extremity joint kinematics, kinetics, and postural stability were assessed and analyzed. Analysis of variance and logistic regression were used to identify predictors of a second anterior cruciate ligament injury. Results Thirteen athletes suffered a subsequent second anterior cruciate ligament injury. Transverse plane hip kinetics and frontal plane knee kinematics during landing, sagittal plane knee moments at landing, and deficits in postural stability predicted a second injury in this population (C statistic = 0.94) with excellent sensitivity (0.92) and specificity (0.88). Specific predictive parameters included an increase in total frontal plane (valgus) movement, greater asymmetry in internal knee extensor moment at initial contact, and a deficit in single-leg postural stability of the involved limb, as measured by the Biodex stability system. Hip rotation moment independently predicted second anterior cruciate ligament injury (C = 0.81) with high sensitivity (0.77) and specificity (0.81). Conclusion Altered neuromuscular control of the hip and knee during a dynamic landing task

  20. A Customizable Chamber for Measuring Cell Migration.

    Science.gov (United States)

    Chowdhury, Aniqa N; Vo, Huu Tri; Olang, Sharon; Mappus, Elliott; Peterson, Brian; Hlavac, Nora; Harvey, Tyler; Dean, Delphine

    2017-03-12

    Cell migration is a vital part of immune responses, growth, and wound healing. Cell migration is a complex process that involves interactions between cells, the extracellular matrix, and soluble and non-soluble chemical factors (e.g., chemoattractants). Standard methods for measuring the migration of cells, such as the Boyden chamber assay, work by counting cells on either side of a divider. These techniques are easy to use; however, they offer little geometric modification for different applications. In contrast, microfluidic devices can be used to observe cell migration with customizable concentration gradients of soluble factors 1 , 2 . However, methods for making microfluidics based assays can be difficult to learn. Here, we describe an easy method for creating cell culture chambers to measure cell migration in response to chemical concentration gradients. Our cell migration chamber method can create different linear concentration gradients in order to study cell migration for a variety of applications. This method is relatively easy to use and is typically performed by undergraduate students. The microchannel chamber was created by placing an acrylic insert in the shape of the final microchannel chamber well into a Petri dish. After this, poly(dimethylsiloxane) (PDMS) was poured on top of the insert. The PDMS was allowed to harden and then the insert was removed. This allowed for the creation of wells in any desired shape or size. Cells may be subsequently added to the microchannel chamber, and soluble agents can be added to one of the wells by soaking an agarose block in the desired agent. The agarose block is added to one of the wells, and time-lapse images can be taken of the microchannel chamber in order to quantify cell migration. Variations to this method can be made for a given application, making this method highly customizable.