WorldWideScience

Sample records for anterior chamber depth

  1. Changes of anterior and posterior corneal curvature and anterior chamber depth after SMILE

    Directory of Open Access Journals (Sweden)

    Li Li

    2017-12-01

    Full Text Available AIM: To observe the changes of anterior and posterior corneal curvature and anterior chamber depth after small incision lenticule extraction(SMILEfor low and high myopic astigmatism. METHODS: Sixty-three cases(88 eyesundergone SMILE in our hospital were included. The patients were divided into two groups based on astigmatism degree: the Group A: -2.00D to -4.00D astigmatism, the Group B: -0.25D to -1.00D astigmatism. Patients were examined at 1wk, 1 and 3mo after operations. Visual acuity, intraocular pressure, refraction, corneal curvature and anterior chamber depth were recorded. The change of anterior and posterior corneal curvature and anterior chamber depth was compared. Spearman correlation analysis and independent t test were used for statistical analysis. RESULTS: Surgery was done well in all patients without complications. No statistically significant difference was found between the two groups in posterior corneal curvature and anterior chamber depth preoperatively, postoperatively 7d,1 and 3mo(P>0.05. One week postoperatively, the anterior corneal curvature was statistically significant from that of preoperative in both groups(PP>0.05. CONCLUSION: No significant change of anterior and posterior corneal curvature and anterior chamber depth was found after SMILE for correcting low and high myopic astigmatism. One week after SMILE the anterior corneal curvature become stable.

  2. Analysis of influence factors on anterior chamber volume by corneal horizontal diameter and anterior chamber depth

    Directory of Open Access Journals (Sweden)

    Ming-Hua Zhang

    2013-08-01

    Full Text Available AIM: To investigate the correlative factors of corneal horizontal diameter(CHDand anterior chamber depth(ACDand discuss the affecting factors of anterior chamber volume(ACV.METHODS: A total of 241 cases(482 eyesof myopia aged 6-47 years were collected on randomly. There were 124(248 eyesmale subjects and 117(234 eyesfemale subjects. CHD and ACD were measured with the Orbscan ⅡZ system, and each measurement was repeated three times. SPSS 17.0 software was used to analyze the correlation data. Mathematical model was set up to research anterior chamber volume. RESULTS: The average of CHD is(11.69±0.51mm, with diameter of(11.74±0.49mm in male and(11.64±0.53mm in female.The average of ACD was(3.04±0.30mm, with depth of(3.07±0.30mm in male and(3.02±0.29in female. Differences in gender of CHD and ACD were significant in the t-test for independent samples(t= -2.265, -1.971; P=0.024, 0.05, these size of male were both larger than that of female. Through person correlation analysis, a negative correlation was found between CHD and age, ACD and age(r= -0.260,-0.246; P=0, 0; a positive correlation was found between CHD and ACD(r=0.297; P=0, the regression equation between CHD and ACD in myopia population was Y=1.025+0.173X(F=46.440,P=0, R2=0.088, where Y represents ACD and X represents CHD. CONCLUSION: There are statistically significant difference between male and female in CHD, ACD and ACV. The size of these in male is larger than in female. The CHD is positively correlated with the ACD, and CHD, ACD and ACV are negatively correlated with age and are not associated with the degree of myopia.

  3. Influence of anterior chamber depth, anterior chamber volume, axial length, and lens density on postoperative endothelial cell loss.

    Science.gov (United States)

    Reuschel, Anna; Bogatsch, Holger; Oertel, Nicole; Wiedemann, Renate

    2015-05-01

    To evaluate the influence of anterior chamber depth (ACD), anterior chamber volume (ACV), lens density (LD), and axial length (AL) as risk factors on endothelial cell loss 3 months after cataract surgery. We enrolled 47 patients with senile cataract who were operated between July 2012 and March 2013 by the same surgeon using torsional phacoemulsification. Preoperatively, we measured ACD, ACV, and LD using the Oculus Pentacam®. The AL was determined using the IOL Master®. Primary outcomes were central endothelial density (ECD) and corrected distance visual acuity (CDVA) 3 months after surgery We evaluated the effect of ACD, ACV, LD, and AL as possible risk factors of postoperative percentage endothelial cell loss (ECL). The median age was 72 years. The median CDVA before surgery was 0.5 improving to 1.0 postoperatively. The median ECL was 5.2 % (range 1.7 %-7.6 %). These results are comparable to our previous study (median ECL 6.9 % after 3 months) [Reuschel et al. (2010) J Cataract Refract Surg]. The median ACD in our study was 2.56 mm (range 2.26 mm-2.8 mm). Median ACV was 144 mm(3) (range 121 mm(3)-158 mm(3)]. The median LD was 12.4 (range 11.4-13.7). Median AL was 23.1 mm (range 22.7 mm-23.9 mm). Our correlation analysis showed no significant correlation between ACD, ACV, LD, AL, and postoperative ECL. ACD, ACV, AL, and LD were not identified as risk factors of postoperative endothelial cell loss in our analysis.

  4. Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices

    Directory of Open Access Journals (Sweden)

    Alberto Domínguez-Vicent

    2014-08-01

    Full Text Available Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D. Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera and the Pentacam HR (single Scheimpflug camera systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured with the Galilei G4 and the Pentacam HR, respectively. The mean white-to-white distance measured was 11.84 ± 0.31 mm and 11.90 ± 0.43 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Mean pupil diameters were measured as 3.22 ± 0.58 mm and 3.22 ± 0.52 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Finally, the mean anterior chamber angle was 34.30 ± 2.86 degrees when it was measured with the Galilei G4, and 39.26 ± 2.85 degrees when measured with the Pentacam HR. A comparative analysis revealed that the Galilei G4 yielded a significantly lower (P0.05 for both devices were obtained for the white-to-white distance measurements. Conclusion: The Galilei G4 and Pentacam HR Scheimpflug systems cannot be used interchangeably because they produce significant measurement differences.

  5. Endothelial Cell Loss after Phacoemulsification according to Different Anterior Chamber Depths.

    Science.gov (United States)

    Hwang, Hyung Bin; Lyu, Byul; Yim, Hye Bin; Lee, Na Young

    2015-01-01

    Purpose. To compare the loss of corneal endothelial cells after phacoemulsification according to different anterior chamber depths (ACDs). Methods. We conducted a prospective study on 135 eyes with senile cataracts. Eyes with nuclear density grades of 2 to 4 were divided into three groups according to ACD: ACD I, 1.5 ACD ≤ 2.5 mm; ACD II, 2.5 ACD ≤ 3.5 mm; or ACD III, 3.5 ACD ≤ 4.5 mm. Intraoperative mean cumulative dissipated energy (CDE) was measured. Clinical examinations included central corneal thickness (CCT) and endothelial cell count (ECC) preoperatively and 2 months postoperatively. Results. There were no significant differences in CDE among the ACD groups (P > 0.05). Endothelial cell loss was significantly higher in ACD I than in ACD III in grades 3 and 4 cataract density groups 2 months after phacoemulsification (P ACD I group compared to the ACD II and III groups 2 months postoperatively, but the difference was not statistically significant. Conclusions. Eyes with shallow ACDs, especially those with relatively hard cataract densities, can be vulnerable to more corneal endothelial cell loss in phacoemulsification surgery.

  6. Comparison of IOL Master contact and immersion A-scan ultrasound measurements of anterior chamber depth

    Directory of Open Access Journals (Sweden)

    Min Xu

    2015-07-01

    Full Text Available AIM: To compare the results of IOL Master, contact and immersion A-scan ultrasound measurements for anterior chamber depth(ACD, and evaluate the difference and consistency.METHODS:Fifty-eight cases(98 eyeswith age-related cataract during July to October in 2013 did the A-scan ultrasound with contact and immersion measurements and IOL Master to get the results of ACD. Difference in measurements between methods was assessed using the variance analysisi. Consistency was assessed using Bland-Altman.RESULTS: The ACD measured by IOL Master was 2.31~3.90mm, the mean was 3.03±0.38mm. The ACD measured by contact A-scan ultrasound was 1.51~4.06mm, the mean was 2.88±0.56mm. The ACD measured by immersion A-scan ultrasound was 1.99~4.17mm, the mean was 3.17±0.38mm. The results of IOL Master and contact A-scan ultrasound had statistical differences(P=0.022P=0.031P=0.000CONCLUSION: The rank of ACD of patients with cataract is immersion A-scan ultrasound, IOL Master and contact A-scan ultrasound. The consistency is poor, and the three methods can't be interchanged clinically.

  7. Anterior chamber depth and refractive change in late postoperative capsular bag distension syndrome: a retrospective analysis.

    Directory of Open Access Journals (Sweden)

    Min Kyu Yang

    Full Text Available To assess the characteristic findings and effects of laser capsulotomy in patients with late postoperative capsular bag distension syndrome (CBDS.Twenty patients diagnosed with late postoperative CBDS between July 2010 and August 2013 were retrospectively reviewed. Before and 1 week after capsulotomy, changes in the anterior chamber depth (ACD were assessed using ultrasound biomicroscopy. Changes in the refractive status and uncorrected visual acuity (UCVA were also measured 1 week and 1 month after capsulotomy. For patients who received bilateral cataract surgery, preoperative ACD and axial length measured by IOLMaster were compared between the two eyes.Twenty-two eyes from 20 patients who had undergone laser capsulotomy showed a mean UCVA improvement of 0.27 ± 0.24 logMAR (range, 0.00-0.90. ACD was increased by an average of +0.04 mm (95% confidence interval, +0.01 to +0.06 mm, p = 0.034, equivalent to predicted refractive change of +0.10 D. The discrepancy between actual (+1.33 D and predicted refractive change after capsulotomy suggests that refractive change may not be generated from IOL displacement in late postoperative CBDS. Preoperative ACD was deeper in the eye with late postoperative CBDS in all bilaterally pseudophakic patients (mean, 3.68 mm vs. 3.44 mm in the fellow eye, p = 0.068.Late postoperative CBDS showed refractive changes that were resolved successfully after laser capsulotomy. The convex lens effects of opalescent material in the distended capsular bag may play a major role in myopic shift. A larger preoperative ACD is possibly associated with the development of late postoperative CBDS.

  8. A Novel Method of Quantitative Anterior Chamber Depth Estimation Using Temporal Perpendicular Digital Photography.

    Science.gov (United States)

    Zamir, Ehud; Kong, George Y X; Kowalski, Tanya; Coote, Michael; Ang, Ghee Soon

    2016-07-01

    We hypothesize that: (1) Anterior chamber depth (ACD) is correlated with the relative anteroposterior position of the pupillary image, as viewed from the temporal side. (2) Such a correlation may be used as a simple quantitative tool for estimation of ACD. Two hundred sixty-six phakic eyes had lateral digital photographs taken from the temporal side, perpendicular to the visual axis, and underwent optical biometry (Nidek AL scanner). The relative anteroposterior position of the pupillary image was expressed using the ratio between: (1) lateral photographic temporal limbus to pupil distance ("E") and (2) lateral photographic temporal limbus to cornea distance ("Z"). In the first chronological half of patients (Correlation Series), E:Z ratio (EZR) was correlated with optical biometric ACD. The correlation equation was then used to predict ACD in the second half of patients (Prediction Series) and compared to their biometric ACD for agreement analysis. A strong linear correlation was found between EZR and ACD, R = -0.91, R 2 = 0.81. Bland-Altman analysis showed good agreement between predicted ACD using this method and the optical biometric ACD. The mean error was -0.013 mm (range -0.377 to 0.336 mm), standard deviation 0.166 mm. The 95% limits of agreement were ±0.33 mm. Lateral digital photography and EZR calculation is a novel method to quantitatively estimate ACD, requiring minimal equipment and training. EZ ratio may be employed in screening for angle closure glaucoma. It may also be helpful in outpatient medical clinic settings, where doctors need to judge the safety of topical or systemic pupil-dilating medications versus their risk of triggering acute angle closure glaucoma. Similarly, non ophthalmologists may use it to estimate the likelihood of acute angle closure glaucoma in emergency presentations.

  9. Central corneal thickness and anterior chamber depth measurement by Sirius® Scheimpflug tomography and ultrasound

    Directory of Open Access Journals (Sweden)

    Jorge J

    2013-02-01

    Full Text Available J Jorge,1 JL Rosado,2 JA Díaz-Rey,1 JM González-Méijome11Clinical and Experimental Optometry Research Laboratory, Center of Physics (Optometry, School of Sciences, University of Minho, Braga, 2Opticlinic, Lisboa, PortugalBackground: The purpose of this study was to compare the accuracy of the new Sirius® Scheimpflug anterior segment examination device for measurement of central corneal thickness (CCT and anterior chamber depth (ACD with that of CCT measurements obtained by ultrasound pachymetry and ACD measurements obtained by ultrasound biometry, respectively.Methods: CCT and ACD was measured in 50 right eyes from 50 healthy subjects using a Sirius Scheimpflug camera, SP100 ultrasound pachymetry, and US800 ultrasound biometry.Results: CCT measured with the Sirius was 546 ± 39 µm and 541 ± 35 µm with SP100 ultrasound pachymetry (P = 0.003. The difference was statistically significant (mean difference 4.68 ± 10.5 µm; limits of agreement −15.8 to 25.20 µm. ACD measured with the Sirius was 2.96 ± 0.3 mm compared with 3.36 ± 0.29 mm using US800 ultrasound biometry (P < 0.001. The difference was statistically significant (mean difference −0.40 ± 0.16 mm; limits of agreement −0.72 to 0.07 mm. When the ACD values obtained using ultrasound biometry were corrected according to the values for CCT measured by ultrasound, the agreement increased significantly between both technologies for ACD measurements (mean difference 0.15 ± 0.16 mm; limits of agreement −0.16 to 0.45 mm.Conclusion: CCT and ACD measured by Sirius and ultrasound methods showing good agreement between repeated measurements obtained in the same subjects (repeatability with either instrument. However, CCT and ACD values, even after correcting ultrasound ACD by subtracting the CCT value obtained with either technology should not be used interchangeably.Keywords: Scheimpflug corneal tomography, ultrasound biometry, ultrasound pachymetry, limits of agreement

  10. Effect of myopic adolescents wearing orthokeratology lens on the corneal surface curvature radius and anterior chamber depth

    Directory of Open Access Journals (Sweden)

    Qian Yu

    2017-06-01

    Full Text Available AIM: To analyze the effect of myopic adolescents wearing orthokeratology lens on the corneal surface curvature radius and anterior chamber depth. METHODS: Totally 120 cases of adolescent myopia were selected, among them 58 cases with 116 eyes were divided into 11-14 years old group and 62 cases with 124 eyes were 15-18 years old group according to the age. They were treated with long-term orthokeratology lens treatment, and two groups of patients were observed before wearing lens(T0, wearing for 6mo(T1, 12mo(T2for uncorrected visual acuity, the average refractive degree improvement, the central corneal thickness, corneal curvature changes and the incidence of complications. RESULTS: The uncorrected visual acuity of the two groups at 12mo after wearing were better than that at 6mo which was better than that before wearing; the diopter had the same trend. The uncorrected visual acuity and the diopter of the 11-14 years old group at 6 and 12mo was better than those of 15-18 years old group with significant difference(PP>0.05. The corneal anterior surface curvature of the two groups at 12mo after wearing were more than that at 6mo which was more than that before wearing. The axial length of the 11-14 years old group was longer than that of the 15-18 years old group with significant difference(PP>0.05. There was no significant difference on the anterior chamber depth between the two groups at different time or between before and after wearing(P>0.05.CONCLUSION: Long-term wearing orthokeratology lenses have a significant effect for control ling juvenile myopia, and can improve the corneal anterior surface curvature, especially in the lower age group, and has no significant effect on the anterior chamber depth.

  11. Is being female a risk factor for shallow anterior chamber? The associations between anterior chamber depth and age, sex, and body height

    Directory of Open Access Journals (Sweden)

    Wei-Cherng Hsu

    2014-01-01

    Full Text Available Aim of Study: To analyze the association between anterior chamber depth (ACD and age, sex, and body height (BH. Materials and Methods: One thousand four hundred eighty eyes of 1480 adults 40 years of age and older receiving preoperative evaluation for cataract surgery were recruited consecutively from June 1, 2006, to December 31, 2010. ACD was measured with the Zeiss IOLMaster. Univariate and multivariate linear regression models were used to analyze the correlations, and receiving operator characteristic (ROC curves and the area under the curve (AUC were used for evaluating the predictability of an ACD less than 2.70 mm. Results: ACD was negatively correlated with age and positively correlated with BH in both univariate and multivariate regression analysis (P < 0.001. Sex was associated with ACD in univariate analysis, but not after adjustment with age and BH. In predicting an ACD less than 2.70 mm, the AUCs of ROC curves for ′age and sex′, ′age and BH′, and ′age, sex, and BH′ were 0.687, 0.689, and 0.689, respectively. Conclusion: Age and BH were independent associating factors of ACD; however, sex was not. Older people and shorter ones likely had shallower ACD, and therefore were predisposed to Primary angle closure glaucoma (PACG. The predictability of ACD by age and BH solely was low, and adding sex did not increase it.

  12. ABCC5, a gene that influences the anterior chamber depth, is associated with primary angle closure glaucoma.

    Directory of Open Access Journals (Sweden)

    Monisha E Nongpiur

    2014-03-01

    Full Text Available Anterior chamber depth (ACD is a key anatomical risk factor for primary angle closure glaucoma (PACG. We conducted a genome-wide association study (GWAS on ACD to discover novel genes for PACG on a total of 5,308 population-based individuals of Asian descent. Genome-wide significant association was observed at a sequence variant within ABCC5 (rs1401999; per-allele effect size =  -0.045 mm, P = 8.17 × 10(-9. This locus was associated with an increase in risk of PACG in a separate case-control study of 4,276 PACG cases and 18,801 controls (per-allele OR = 1.13 [95% CI: 1.06-1.22], P = 0.00046. The association was strengthened when a sub-group of controls with open angles were included in the analysis (per-allele OR = 1.30, P = 7.45 × 10(-9; 3,458 cases vs. 3,831 controls. Our findings suggest that the increase in PACG risk could in part be mediated by genetic sequence variants influencing anterior chamber dimensions.

  13. Distribution of axial length, anterior chamber depth, and corneal curvature in an aged population in South China.

    Science.gov (United States)

    Chen, Hui; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Chen, Weirong

    2016-05-01

    Ocular biometry is important for preoperative assessment in cataract and anterior segment surgery. The purpose of this study was to investigate normative ocular biometric parameters and their associations in an older Chinese population. This was a cross-sectional observational study. From 2013 to 2014, we recruited inhabitants aged 50 years or older in Guangzhou, China. Among 1,117 participants in the study, data from 1,015 phakic right eyes were used for analyses. Ocular parameters including axial length (AL), anterior chamber depth (ACD), and corneal curvature (K) were measured using an IOL Master. The mean AL, ACD, and K were 23.48 mm [95 % confidence interval (CI), 23.40-23.55], 3.03 mm (CI, 3.01-3.05), and 44.20 mm (CI, 44.11-44.29), respectively. A mean reduction in ACD with age was observed (P = 0.002) in male subjects but not in female subjects (P = 0.558). Male subjects had significantly longer ALs (23.68 mm versus 23.23 mm, P population in South China. The AL in this Chinese cohort was greater than that observed in the Singaporean Chinese but smaller than that observed in Malaysia and for Caucasians. The Chinese have a shallower ACD than some other racial groups. Age and sex were the most consistent predictors of ocular biometry in the older population from South China.

  14. Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation

    Directory of Open Access Journals (Sweden)

    Sirel Gür Güngör

    2016-12-01

    Full Text Available Objectives: To compare anterior chamber depth (ACD changes after phacoemulsification surgery in patients with pseudoexfoliation syndrome (PEX and normal patients using an anterior segment imaging method. Another aim of this study was to evaluate the effect of these changes on the accuracy of intraocular lens (IOL power calculation and postoperative refraction. Materials and Methods: Twenty-two eyes of 22 patients with PEX and 30 eyes of 30 normal patients who underwent uneventful phacoemulsification surgery and IOL implantation were included in the study. The ACD of all patients was evaluated preoperatively and at 3 months postoperatively with the ALLEGRO Oculyzer (WaveLight® Oculyzer™ II, Alcon, Novartis-Scheimpflug imaging system. Results: The postoperative mean ACD values were significantly larger than the preoperative ACD values in both groups (p<0.001 for both groups. The pre- to postoperative change in ACD was 0.46±0.3 mm in the PEX group, which was a larger change than seen in the normal patients (0.12±0.1 mm (p=0.04. The mean absolute errors (MAE calculated with different IOL formulas (SRK/T, Haigis, Hoffer and Holladay 1 formulas were comparable and no statistically significant difference was observed between the two groups (p=0.21. Conclusion: Phacoemulsification induces more significant ACD changes in patients with PEX compared to normal patients. However, the MAE did not differ significantly between the groups.

  15. Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation

    Science.gov (United States)

    Gür Güngör, Sirel; Akman, Ahmet; Asena, Leyla; Aksoy, Mustafa; Sarıgül Sezenöz, Almila

    2016-01-01

    Objectives: To compare anterior chamber depth (ACD) changes after phacoemulsification surgery in patients with pseudoexfoliation syndrome (PEX) and normal patients using an anterior segment imaging method. Another aim of this study was to evaluate the effect of these changes on the accuracy of intraocular lens (IOL) power calculation and postoperative refraction. Materials and Methods: Twenty-two eyes of 22 patients with PEX and 30 eyes of 30 normal patients who underwent uneventful phacoemulsification surgery and IOL implantation were included in the study. The ACD of all patients was evaluated preoperatively and at 3 months postoperatively with the ALLEGRO Oculyzer (WaveLight® Oculyzer™ II, Alcon, Novartis)-Scheimpflug imaging system. Results: The postoperative mean ACD values were significantly larger than the preoperative ACD values in both groups (p<0.001 for both groups). The pre- to postoperative change in ACD was 0.46±0.3 mm in the PEX group, which was a larger change than seen in the normal patients (0.12±0.1 mm) (p=0.04). The mean absolute errors (MAE) calculated with different IOL formulas (SRK/T, Haigis, Hoffer and Holladay 1 formulas) were comparable and no statistically significant difference was observed between the two groups (p=0.21). Conclusion: Phacoemulsification induces more significant ACD changes in patients with PEX compared to normal patients. However, the MAE did not differ significantly between the groups. PMID:28050320

  16. Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation.

    NARCIS (Netherlands)

    Doors, M.; Cruysberg, L.P.J.; Berendschot, T.T.; Brabander, J. De; Verbakel, F.; Webers, C.A.; Nuijts, R.M.

    2009-01-01

    BACKGROUND: The repeatability and interchangeability of imaging devices measuring central corneal thickness (CCT) and anterior chamber depth (ACD) are important in the assessment of patients considering refractive surgery. The purpose of this study was to investigate the agreement of CCT and ACD

  17. Comparison between a New Optical Biometry Device and an Anterior Segment Optical Coherence Tomographer for Measuring Central Corneal Thickness and Anterior Chamber Depth

    Directory of Open Access Journals (Sweden)

    Jinhai Huang

    2016-01-01

    Full Text Available Purpose. To compare between a new optical biometer (AL-Scan, Nidek Co., Aichi, Japan and an anterior segment optical coherence tomographer (Visante AS-OCT, Carl Zeiss Meditec, Dublin, USA for measuring central corneal thickness (CCT, anterior chamber depth (ACD, and aqueous depth (AD. Methods. Sixty-three eyes of 63 normal subjects were examined with AL-Scan and Visante AS-OCT in this prospective study. One eye per subject was measured three times with both devices to record their CCT, ACD, and AD. All procedures were performed by the same operator. Agreement between the two devices was assessed using paired t-tests, Bland-Altman plots, and 95% limits of agreement (LoA. Results. The mean CCT, ACD, and AD measured by AL-Scan were 538.59±27.37 μm, 3.70±0.30 mm, and 3.16±0.30 mm, respectively. The mean values obtained by the Visante OCT were 536.14±26.61 μm for CCT, 3.71±0.29 mm for ACD, and 3.17±0.29 mm for AD. The mean CCT by the AL-Scan was higher than that obtained by the Visante AS-OCT (difference = 2.45±6.07 μm, P<0.05. The differences in ACD and AD measurements were not statistically significant. The 95% LoA of CCT, ACD, and AD were between −9.44 and 14.35 μm, −0.15 and 0.12 mm, and −0.15 and 0.12 mm, respectively. Conclusions. Since these two devices were comparable for measuring CCT, ACD, and AD, their results can be interchangeably used in the clinic.

  18. The effect of Nd:YAG laser treatment of posterior capsule opacification on anterior chamber depth and refraction in pseudophakic eyes

    Directory of Open Access Journals (Sweden)

    Khambhiphant B

    2015-03-01

    Full Text Available Bharkbhum Khambhiphant,1 Chayata Liumsirijarern,2 Piyada Saehout1 1Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, 2Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand Purpose: This was a prospective descriptive study to determine the changes in intraocular lens (IOL position after neodymium-doped yttrium–aluminum–garnet (Nd:YAG laser posterior capsulotomy by measuring anterior chamber depth (ACD and refraction, including the spherical equivalent (SE and cylinder. Materials and methods: Forty-seven pseudophakic eyes with posterior capsule opacification of 29 patients were included. Nd:YAG laser posterior capsulotomy was performed. Patients’ ACD and refraction were measured before the treatment, as well as after the treatment at 1 week and 3 months. IOLMaster® and an automated refractometer were used at the Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand. Results: There were no statistically significant differences in ACD and SE before and after laser treatment at 1 week and 3 months (repeated analysis of variance, P=0.582 and P=0.269, respectively. Both backward IOL movement (number [n]=29 and forward IOL movement (n=18 were found. Some changes in cylindrical refraction were found at 1 week, but decreased at 3 months after capsulotomy (baseline cylinder: -1.16; cylinder at 1 week and 3 months: -1.00 and -1.14, respectively; P=0.012. These changes were the same with one-piece and three-piece IOLs. Conclusion: Nd:YAG laser posterior capsulotomy did not significantly change ACD and SE. It led to cylinder change at 1 week after laser, but the effect decreased at 3 months. This effect was small and may not be clinically significant. Keywords: posterior capsule opacification, neodymium-doped yttrium–aluminum–garnet, anterior chamber depth, pseudophakia, refraction

  19. Gnathostomiasis of the anterior chamber

    Directory of Open Access Journals (Sweden)

    Barua P

    2007-01-01

    Full Text Available Ocular involvement with Gnathostoma spinigerum occurs years after the initial infection that is acquired by ingestion of poorly cooked, pickled seafood or water contaminated with third stage larvae. Here we report a case of gnathostomiasis of the left eye of a 32-year-old lady hailing from Meghalaya, India. Her vision had deteriorated to hand movement. Slit lamp examination revealed a live, actively motile worm in the anterior chamber, which was extracted by supra temporal limbal incision and visual acuity was restored.

  20. Anterior chamber volume. Its measurement and clinical application.

    Science.gov (United States)

    Coakes, R L; Lloyd-Jones, D; Hitchings, R A

    1979-04-01

    Measurement of anterior chamber volume is discussed and attention drawn to a new, convenient slit-image method, which was used to study anterior chamber depth and volume before and after prophylactic peripheral iridectomy in the fellow eyes of patients presenting with unilateral acute angle-closure glaucoma. There was no significant change in depth after iridectomy but the mean anterior chamber volume increased significantly (P less than 0.01), by nearly 3 per cent. This increase was due to elimination of peripheral iris bombé which was not present in two control groups of normal eyes, one matched for anterior chamber depth and the other for age and refraction. Peripheral iris bombé may be a quantifiable factor predisposing to the development of acute angle-closure glaucoma.

  1. Anterior chamber depth and iris and lens position before and after phacoemulsification in eyes with a short or long axial length.

    Science.gov (United States)

    Muzyka-Woźniak, Maria; Ogar, Angelika

    2016-04-01

    To evaluate changes in anterior segment parameters after phacoemulsification in short eyes and long eyes. Spektrum Eye Clinic, Wrocław, Poland. Prospective comparative study. Anterior segment parameters were examined before and after phacoemulsification in 3 groups of eyes as follows: short (axial length [AL] 25.5 mm) with optical biometry based on partial coherence interferometry (IOLMaster) and anterior segment optical coherence tomography (Visante). The study comprised 20 short eyes, 22 normal eyes, and 19 long eyes. The anterior chamber angle increased after surgery in all eyes (P position after phacoemulsification was larger in short eyes than in normal or long eyes (mean change 0.93 mm, 0.70 mm, and 0.43 mm, respectively) (P position after phacoemulsification in relation to the iris was smaller in short eyes (mean 0.51 mm) than in normal or long eyes (mean 0.82 mm and 1.10 mm, respectively) (P position occurred in short eyes. The largest change in the lens versus the intraocular lens (IOL) position occurred in long eyes, with the IOL moving back from the iris. Optical biometry might underestimate the postoperative ACD. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. Anterior chamber collapse syndrome in a koala.

    Science.gov (United States)

    Liddle, Vl; Naranjo, C; Bernays, Me

    2014-05-01

    Anterior chamber collapse syndrome has been recognised in various species and is associated with early-life ocular disease or trauma. It is important to differentiate this acquired condition from a congenital malformation. An adult female koala (Phascolarctos cinereus) was referred for assessment of buphthalmos and severe keratitis of the right eye. The degree of keratitis obstructed examination of intraocular structures. Enucleation of the affected eye was performed and the histopathological diagnosis was anterior chamber collapse syndrome and secondary glaucoma. This case contributes to the limited information available in the literature on anterior chamber collapse syndrome, a disease unique in having secondary glaucoma with minimal or no inflammation. The case also expands the literature available on ocular disease in koalas. More specifically, this is the only reported case of glaucoma, of any aetiology, in the koala. © 2014 Australian Veterinary Association.

  3. [Radiographic anatomy of pulp chamber of Chinese permanent anterior teeth].

    Science.gov (United States)

    Jia, Liu-He; Huang, Ming-Ding; Gao, Xiao-Jie; Luo, Shi-Gao; Luo, Hong-Xia; Tan, Hong; Zhou, Xue-Dong

    2006-06-01

    The aim of this study was to measure and analyze the anatomic characteristics of the pulp chamber of Chinese permanent anterior teeth radiographically. There were 137 human permanent anterior teeth to be used. The crown length, crown width and crown thickness were measured by vernier caliper. Labial-lingual and mesial-distal radiographs were obtained by parallel technique and Photoshop 8.0 was adopted for measuring the largest labial-lingual length, the largest mesial-distal length, the pulp chamber height and the distance between the lingual surface of the crown and the corresponding wall of the pulp chamber; the ratios of the largest labial-lingual length to the crown thickness, the largest mesial-distal length to the crown width and the pulp chamber height to the crown length were calculated. Finally the coefficients of variance were caculated. (1) The ratios of the largest mesial-distal length to the crown width of maxillary and mandibular canines were statistically different from those of the other anterior teeth. There was not statistically significant difference for those ratios either between maxillary and mandibular canines or among incisors. (2) Indexes of the pulp chamber had higher variance than those of the external morphology. (3) The distance between the lingual surface of the crown and the corresponding wall of the pulp chamber had the smallest coefficient of variance. (4) The largest mesial-distal length of the pulp chamber had the largest coefficient of variance, except for the mandibular canines. This study provided anatomical basis for clinical work; the distance between the lingual surface of the crown and the corresponding wall of the pulp chamber could be used as a depth reference for the endodontic access, and the access should not be extended excessively in mesial-distal direction.

  4. Evaluation of the Effects of Menstrual Cycle on Anterior Chamber Parameters as Measured with Pentacam

    Directory of Open Access Journals (Sweden)

    Arzu Seyhan Karatepe

    2013-01-01

    Full Text Available Pur po se: To evaluate the effects of endogenous gonadotropic hormones (follicle-stimulating hormone, luteinizing hormone and sex steroids (progesterone, estrogen to anterior segment parameters. Ma te ri al and Met hod: Thirty healthy females who had a menstrual cycle of 28±1 day and with a mean age of 36.5±7.56 (range, 20 – 46 years were included in the study. Starting from the first day of their cycle, Pentacam Scheimpflug camera measurements were performed on the 1st, 3rd, 7th, 12th, 16th, 21st, 26th, and 28th days. The central corneal thickness, anterior chamber depth, anterior segment volume, keratometric values, anterior chamber angle value, and pupilla diameter of both eyes were evaluated. Repeated measures analysis of variance test was used for statistical analysis. Re sults: No difference that reaches statistical significance was found in the means of central corneal thickness, anterior chamber volume, keratometric values, anterior chamber angle, and pupilla diameter between the days. Mean anterior chamber depth measurement of the right eyes on the 1st day was 2.72±0.44 mm, whereas it was 2.77±0.46 mm on the 26th day. Mean anterior chamber depth measurement of the left eyes on the 1st day was 2.74±0.42 mm, whereas it was 2.80±0.43 mm on the 26th day. This increment of anterior chamber depth value from the 1st to the 26th days was found to be statistically significant (p≤0.05. Dis cus si on: Progesterone and estrogen that rise in the second half of the menstrual cycle might have a deepening effect on the anterior chamber. These findings should be further investigated with more profound studies that also evaluate the hormonal values and their correlations with anterior segment parameters. (Turk J Ophthalmol 2013; 43: 15-8

  5. RETAINED STONE PIECE IN ANTERIOR CHAMBER

    Directory of Open Access Journals (Sweden)

    ZvornicaninJasmin, Nadarevic-VodencarevicAmra

    2015-04-01

    Full Text Available ABSTRACT We read with interest the article by Surekha et al. regarding the retained stone piece in anterior chamber. Similar to the results of previous studies, the authors found that delayed intraocular foreign body (IOFB management can result in good visual outcome without an apparent increased risk of endophthalmitis or other deleterious side effects. However, the authors failed to explain the exact reason for the diminution of vision in patients left eye. It is unclear what the uncorrected visual acuity was and what kind of correction was used, more precisely type and amount of cylinder, given the presence of the corneal opacity. Since the size of the IOFB is approximately 4x4x1mm, significant irido-corneal angle changes resulting in intraocular pressure raise and optic nerve head damage can be expected. Traumatic glaucoma following open globe injury can occur in 2.7 to 19% of cases, with several risk factors associated with glaucoma development (advanced age, poor visual acuity at presentation,perforating rather than penetrating ocular injury,lens injury, presence of vitreous hemorrhage and presence of an IOFB. Earlier reportsof latetraumaticoptic neuropathy onset, even after several years, indicate that this possibility cannot be completely ruled out too. Therefore, repeated intraocular pressure measurements, gonioscopy, pupillary reaction assessment, together with through posterior segment examination including visual field and optical coherence tomography examinations can be useful in determining the possible optic nerve damage as one of the possible reasons for visual acuity reduction. The authors did not suggest any operative treatment at this time. However, it should bear in mind that the inert anterior chamber IOFB could be a risk factor for non-infectious endophthalmitis development even after many years. Also, long term retained anterior chamber foreign body leads to permanent endothelial cell loss and can even result in a corneal

  6. Foreign Body Embedded in Anterior Chamber Angle

    Directory of Open Access Journals (Sweden)

    Shmuel Graffi

    2012-01-01

    Full Text Available Introduction. We present a case of a metallic foreign body embedded in the anterior chamber angle. After standing in close proximity to a construction worker breaking a tile, a 26-year-old woman using soft contact lens for the correction of mild myopia presented to emergency department for evaluation of a foreign body sensation of her right eye. Methods and Results. Diagnosis was confirmed by gonioscopic examination and a noncontrast CT scan of head and orbits. The foreign body was removed by an external approach without utilizing a magnet. The patient's final outcome was favorable. Discussion. The above is a rare clinical situation, which is impossible to detect on slit-lamp examination without a gonioscopic view. Proper imaging and a specific management are mandatory in order to achieve favorable outcome.

  7. Dynamic analysis of dark-light changes of the anterior chamber angle with anterior segment OCT.

    Science.gov (United States)

    Leung, Christopher Kai-shun; Cheung, Carol Yim Lui; Li, Haitao; Dorairaj, Syril; Yiu, Cedric Ka Fai; Wong, Amy Lee; Liebmann, Jeffrey; Ritch, Robert; Weinreb, Robert; Lam, Dennis Shun Chiu

    2007-09-01

    To describe the use of anterior segment optical coherence tomography (OCT) in studying the dynamic dark-light changes of the anterior chamber angle. Thirty-seven normal subjects with open angles on dark-room gonioscopy and 18 subjects with narrow angles were analyzed. The dynamic dark-light changes of the anterior-chamber angle were captured with real-time video recording. The angle opening distance (AOD500) and trabecular iris space area (TISA500) of the nasal angle and the pupil diameter in each of the representative serial images were measured. Linear regression analysis was performed to investigate the association between AOD500/TISA500 and pupil diameter. Demographic and biometry measurements associated with the AOD difference (AOD500((light)) - AOD500((dark))) and TISA difference (TISA500((light)) - TISA500((dark))) were analyzed with univariate and multivariate regression models. The AOD500/TISA500 measured in the light in the open-angle and the narrow-angle groups were 694 +/- 330 microm/0.24 +/- 0.10 mm(2) and 265 +/- 78 microm/0.10 +/- 0.03 mm(2), respectively. These values were significantly greater than the AOD500/TISA500 measured in the dark (492 +/- 265 microm/0.16 +/- 0.08 mm(2) and 119 +/- 82 microm/0.05 +/- 0.04 mm(2), respectively, all with P chamber depth and the AOD/TISA difference. Fifty eyes showed significant correlations between AOD/TISA and pupil diameter, whereas one eye showed no association. Four eyes in the narrow angle group developed appositional angle closure in the dark. The dynamic dark-light changes of the anterior chamber angle can be imaged and analyzed with anterior segment OCT. Although the angle width generally decreased linearly with increasing pupil diameter, the differences of the angle width measured in the dark and in the light varied substantially among individuals.

  8. A simple photogrammetric method of measuring anterior chamber volume.

    Science.gov (United States)

    Johnson, S B; Coakes, R L; Brubaker, R F

    1978-04-01

    We devised a convenient method of measuring anterior chamber volume in man. Photographs of the anterior chamber were taken with a Zeiss photographic slit lamp with a Polaroid attachment, and measured with a specially constructed transparent scale. Using this method, the standard deviation of individual measurements of volume on different occasions in a given eye was 8 microliter. The standard deviation of the differences between right and left eyes of normal subjects was 10 microliter. The volume of the anterior chamber measured in 78 eyes of 39 normal subjects (mean age, 28 years; range, 19 to 56 years) was found to be 209 +/- 37 microliter (mean +/- SD). We observed a small negative correlation between the age of the subject and the volume of the anterior chamber.

  9. Influence of anterior segment biometric parameters on the anterior chamber angle width in eyes with angle closure.

    Science.gov (United States)

    Matsuki, Takaaki; Hirose, Fumitaka; Ito, Shin-Ichiro; Hata, Masayuki; Hirami, Yasuhiko; Kurimoto, Yasuo

    2015-02-01

    To predict angle narrowing in eyes with angle closure in a Japanese population using anterior segment optical coherence tomography (AS-OCT) quantitative parameters. AS-OCT was used to examine 118 eyes of 118 patients with angle closure and 40 eyes of 40 patients with open angle under dark conditions. After measuring the angle opening distance 500 (AOD500), anterior chamber depth, iris thickness (IT), iris convexity (IC), pupil diameter, anterior chamber width, and crystalline lens rise, multivariate regression analyses were performed for the AOD500 in each group. With the exception of IT, significant differences were observed between the AS-OCT parameters for the angle closure and open-angle groups. Anterior chamber depth, IT, and IC were the explanatory variables associated with AOD500 for each group (P≤0.001). A significant negative association was found between IT and IC only in the angle-closure group (Pchamber depth was a major mechanism of angle narrowing, and that both IT and IC had a strong impact on angle narrowing. Moreover, the negative association found between IT and IC in only the angle closure group indicated the existence of the stretch force placed on the iris by relative pupillary block.

  10. Evaluation of the change of anterior chamber parameters before and after laser peripheral iridectomy in primary angle-closure suspetive with Pentacam anterior segment analysis system

    Directory of Open Access Journals (Sweden)

    Chi Du

    2015-05-01

    Full Text Available AIM:To investigate the sensitive parameters of the anterior chamber changes with Pentacam anterior segment analysis system before and after laser peripheral iridectomy(LPIin primary angle-closure suspetive(PACS.METHODS: Sixty eyes of 33 PACS patients were enrolled in this study. Pentacam examination was performed before and 1d after LPI to measure the central anterior chamber depth(CACD, the peripheral anterior chamber depth(PACD, the anterior chamber volume(ACVand the peripheral anterior chamber angle(ACA. Statistical analysis used paired t test. RESULTS: There was no statistical significance on the changes of ACD. PACD and ACV increased significantly between before and 1d after LPI. ACA was widened from(22.26°±5.18°to(26.42°±5.20°, which were increased significantly between before and 1d after LPI.CONCLUSION: LPI can deepen the PACD and increase the ACV in PACS. PACD and ACV are the sensitive parameters of the anterior chamber changes with Pentacam anterior segment analysis system.

  11. Measurement of and Factors Associated with the Anterior Chamber Volume in Healthy Chinese Adults

    Directory of Open Access Journals (Sweden)

    Yuan Zong

    2017-01-01

    Full Text Available Purpose. To measure the anterior chamber volume (ACV and determine factors associated with the ACV in healthy Chinese adults. Methods. In this cross-sectional study, we used swept-source optical coherence tomography (SS-OCT to measure ACV and other anterior segment parameters. Factors associated with ACV were also determined. Results. A total of 313 healthy Chinese adults were enrolled. The anterior segment parameters, including ACV, could be measured by SS-OCT with excellent repeatability and reproducibility. There was a significant difference between the horizontal and vertical anterior chamber widths (ACW (P<0.05, with a mean difference of 390 μm. The ACV (mean 153.83±32.42 mm3 was correlated with most of the anterior segment parameters, especially anterior chamber depth (ACD, which accounted for about 85% of the variation of ACV. Most of the anterior segment parameters were significantly correlated with age, and the relative changes in ACV and ACD were greatest in subjects aged 41–50 years. Conclusion. ACV was correlated with most of the anterior segment parameters measured in this study, particularly ACD. The relatively large difference between horizontal and vertical ACW suggests that the ACV could and should be measured using multiple OCT scans.

  12. Clearance from the anterior chamber of RBCs from human diabetics

    International Nuclear Information System (INIS)

    Williams, G.A.; Hatchell, D.L.; Collier, B.D.; Knobel, J.

    1984-01-01

    Erythrocytes from diabetic patients manifest decreased deformability and increased adherence. These abnormal membrane properties may diminish the ability of erythrocytes (RBCs) from diabetics to undergo deformation in passage through the trabecular meshwork. Using sodium chromate Cr 51-labeled RBCs from type I diabetic patients with proliferative retinopathy and normal control subjects, we studied RBC clearance from the rabbit anterior chamber. The mean time for 50% clearance (T50) of RBCs from diabetics (76 hours) was significantly longer than that for RBCs from normal subjects (19.5 hours). In this model, RBCs from diabetics have a slower clearance from the anterior chamber than do RBCs from normal subjects

  13. Anterior lamina cribrosa surface depth in healthy Saudi females

    Directory of Open Access Journals (Sweden)

    El-Agamy A

    2017-06-01

    Full Text Available Amira El-Agamy,1,2,* Fayrouz Oteaf,1,* Mohamed Berika3,4 1Department of Optometry and Vision Sciences, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia; 2Mansoura Ophthalmic Center, Faculty of Medicine, Mansoura University, Mansoura, Egypt; 3Rehabilitation Science Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia; 4Anatomy Department, Faculty of Medicine, Mansoura University, Mansoura, Egypt *These authors contributed equally to this work Purpose: This study was conducted to determine normative profile of anterior lamina ­cribrosa surface depth (ALCSD in healthy Saudi females using Topcon Three-Dimensional (3D Optical Coherence Tomography (OCT 2000 – Spectral Domain (SD-OCT. In addition, the correlation between ALCSD and other clinical factors such as age, refractive error, intraocular pressure (IOP, central corneal thickness, anterior chamber depth, axial length, retinal nerve fiber layer thickness, and disk area was also assessed.Design: This study was a prospective, nonrandomized, cross-sectional, observational, and quantitative study.Methods: This study included 191 eyes of 191 healthy Saudi females from the College of Applied Medical Sciences of King Saud University. Stereoscopic disk photographs were reconstructed using Topcon 3D OCT-2000 for all subjects. ALCSD was measured at three planes (superior, middle, and inferior and defined as the distance from Bruch’s membrane opening level (reference line to anterior lamina cribrosa surface. Average of ALCSD at all planes was defined as mean ALCSD of the eye. Correlation between ALCSD and all the clinical factors was performed by linear regression analysis. Paired t-test was performed in order to compare ALCSD at all planes.Results: In this study, the average ALCSD was 371.88±114.62 µm (range, 155–647.6 µm. Paired t-test showed a significant difference between superior and middle planes (P=0.004 and middle and

  14. [Analysis of anatomy features for patients with narrow anterior chamber angle and primary iridociliary body cysts].

    Science.gov (United States)

    Li, Gui-gang; Ji, Cai-ni; Li, Xin-yu; Hu, Wei-kun; Hu, Jun; Wang, Jun-ming; Li, Tao; Li, Bin; Zhang, Hong

    2012-08-01

    To investigate the prevalence and anatomy features of iridociliary body cysts in patients with narrow anterior chamber angle. Retrospective case series study. The prevalence and anatomy features of iridociliary body cysts in 223 patients (402 eyes) were analyzed retrospectively with ultrasound biomicroscopy (UBM). All of the patients were examined for susceptive narrow anterior chamber angle without complaint. The age of the patients, the site, diameter and number of cysts, the anterior chamber angle and the central anterior chamber depth were measured. Iridociliary body cysts were found in 19 patients (23 eyes) out of 223 patients (402 eyes), the prevalence is 5.7%. Fifteen patients were unilateral and four patients bilateral. Two cases originated from the ciliary process, eighteen cases from the iris root, and three from both the root and posterior surface of the iris. Twenty one cases were single cysts while two cases were multiple cysts. The diameter of the cysts ranged from 0.5 to 3.1 mm, averaged (0.71 ± 0.53) mm. The average age and the central anterior chamber depth of the eyes with iridociliary body cysts were (55.32 ± 10.74) years and (2.25 ± 0.39) mm, with no significant difference (t = 0.534, 0.783; P > 0.05) as compared to that of patients without cysts, which were (57.46 ± 10.52) years and (2.14 ± 0.34) mm. The anterior chamber angle in iridociliary body cysts group was 8.2° (21.0°, 0.0°), with no significant difference (Z = -0.062, P > 0.05) as compared to that of patients without cysts, which was 8.9° (21.4°, 0.0°). The prevalence rate of iridociliary body cysts in this study is 5.7%, central anterior chamber depth and anterior chamber angle in patients with cysts do not differ form patients without cysts.

  15. Predictive factors for anterior chamber fibrin formation after vitreoretinal surgery

    Directory of Open Access Journals (Sweden)

    Leonardo Provetti Cunha

    2014-04-01

    Full Text Available Purpose: The aim of this study was to investigate possible predictive factors related to anterior chamber fibrin formation after vitreoretinal surgery in a large series of patients. Methods: The data of 185 eyes of 185 patients submitted to vitreoretinal surgery was reviewed. The following variables were evaluated: the postoperatively presence of fibrin, age, diabetes mellitus, the vitrectomy system gauge (20, 23 or 25 gauge, the type of vitreous substitute, the influence of prior surgical procedures and the combination with cataract extraction. To evaluate predictive factors for anterior chamber fibrin formation, univariate analysis was performed. A multivariate stepwise logistic regression model was adjusted to investigate factors associated with fibrin formation (p<0.05. Results: Fibrinoid anterior chamber reaction was found in 12 (6.4% patients. For multivariate logistic regression analysis, balanced salt solution (BSS, the chance of fibrin occurrence was 5 times greater (odds ratio 4.83, CI 95% 1.302 - 17.892; p=0.019, while combination with phacoemulsification increased the chance of fibrin formation by 20 times (odds ratio 20, CI 95% 2.480 - 161.347; p=0.005. No significant difference was found regarding other variables. Conclusion: Anterior chamber fibrin formation is an unwanted complication after vitreoretinal surgery. Factors such as combined performance of phacoemulsification and the use of balanced salt solution as a vitreous substitute may predispose the occurrence of this complication.

  16. Anterior chamber gas bubbles in open globe injury.

    Science.gov (United States)

    Barnard, E B G; Baxter, D; Blanch, R

    2013-01-01

    We present a case of a 40-year-old soldier who was in close proximity to the detonation of an improvised explosive device (IED). Bubbles of gas were visible within the anterior chamber of his left eye. The authors propose that intraocular gas, present acutely after trauma, is diagnostic of open globe injury and is of particular importance in remote military environments.

  17. Microbiological profile of anterior chamber aspirates following uncomplicated cataract surgery

    Directory of Open Access Journals (Sweden)

    Prajna N

    1998-01-01

    Full Text Available Anterior chamber aspirate cultures were done for 66 patients who underwent either an uncomplicated intracapsular cataract extraction, extracapsular cataract extraction with posterior-chamber intraocular lens implantation, or phacoemulsification with posterior-chamber intraocular lens implantation. The aspirate was obtained at the time of wound closure. The aspirates were immediately transferred to the microbiology laboratory where one drop of the aspirate was placed on a glass slide for gram stain, and the remainder was unequally divided and inoculated into blood agar, chocolate agar and thioglycolate broth. The cultures were incubated at 37° C with 5% CO2 and held for 5 days. Of 66 patients 4 (6%, had smear-positive anterior chamber aspirates. None of the aspirates showed any growth on any of the 3 culture media used. None of the eyes in the study developed endophthalmitis. This study concludes that there is no contamination of the anterior chamber by viable bacteria after cataract surgery, irrespective of the mode of intervention.

  18. Evaluation of the anterior chamber angle in pseudoexfoliation syndrome.

    Science.gov (United States)

    Iwanejko, Małgorzata; Turno-Kręcicka, Anna; Tomczyk-Socha, Martyna; Kaczorowski, Kamil; Grzybowski, Andrzej; Misiuk-Hojło, Marta

    2017-08-01

    Pseudoexfoliation syndrome (PEX) is the most frequently identifiable cause of secondary open-angle glaucoma, known as pseudoexfoliation glaucoma. The exact pathophysiology and etiology of PEX and associated glaucoma remains obscure. The purpose of this study was to determine the differences in the morphology of the anterior chamber angle in people with pseudoexfoliation syndrome and pseudoexfoliation glaucoma compared to a control group. We also evaluated the correlation between intraocular pressure (IOP) and pigmentation of the angle with the amount of exfoliated material in the anterior segment. The study group was composed of 155 eyes from 103 patients aged between 43 and 86 years. Each patient underwent a complete ophthalmological examination. Some difference was found in intraocular pressure between the PEX group and the control group and between the pseudoexfoliation glaucoma group and the control group, but no significant difference was found between the 2 study groups. There was a significant difference in the incidence of some degree of pigmentation in the anterior chamber angle and no difference in the widths of the angle between each group. A significant positive relationship was observed between intraocular pressure and the degree of pigmentation of the anterior chamber angle in both the PEX group and the pseudoexfoliation glaucoma group. The results of this study indicate that the amount of pigmentation and exfoliation material in the anterior segment significantly correlates with the level of IOP and possibly with the degree of trabecular dysfunction. It seems that for clear identification of PEX and pseudoexfoliation glaucoma factors, clinical assessment appears to be insufficient.

  19. Anatomic predictors for anterior chamber angle opening after laser peripheral iridotomy in narrow angle eyes.

    Science.gov (United States)

    Huang, Guofu; Gonzalez, Eduardo; Lee, Roland; Osmonavic, Senad; Leeungurasatien, Thidarat; He, Mingguang; Lin, Shan C

    2012-07-01

    To investigate anterior chamber parameters and biometric factors associated with degree of angle opening after laser peripheral iridotomy (LPI) for narrow angles. In this prospective cohort study, patients with narrow angles who were scheduled for LPI were recruited. Anterior chamber parameters by anterior segment coherence tomography (ASOCT) under dark conditions were compared before and after LPI. Only the right eye was used for analysis if both eyes were eligible. Measurements performed by customized software included anterior chamber depth, iris area, angle opening distance at 500 µm (AOD500) anterior to the scleral spur, iris thickness at 750 µm from sclera spur (IT750), trabecular-iris space area 500 (TISA500), and iris curvature (I-Curv). Univariate and multiple regression analyses were performed to determine the predictive factors of angle opening after LPI. Eighty-one patients with narrow angles were prospectively recruited in this study. The AOD500 increased significantly from 0.128 ± 0.081 mm (before) to 0.209 ± 0.087 mm (after) in the nasal quadrant, and from 0.103 ± 0.067 mm (before) to 0.197 ± 0.071 mm (after) in the temporal quadrant (p chamber angle widening after LPI were older age, smaller iris area, and steeper iris.

  20. Comparison of Mydriatic Provocative and Dark Room Prone Provocative Tests for Anterior Chamber Angle Configuration.

    Science.gov (United States)

    Yamada, Rika; Hirose, Fumitaka; Matsuki, Takaaki; Kameda, Takanori; Kurimoto, Yasuo

    2016-06-01

    To investigate the relationship between angle configuration and diagnostic provocation tests such as the mydriatic provocative test (MPT) and the dark room prone provocative test (DRPPT). Seventy eyes of 70 consecutive patients with primary angle closure suspect, primary angle closure, or primary angle closure glaucoma were included. The anterior chamber depth, angle opening distance 500, trabecular-iris space area 500, and iris thickness (IT) were quantitatively determined by anterior segment optical coherence tomography, and the MPT and DRPPT were used to investigate intraocular pressure variations. Seven eyes were positive and 3 eyes were suspected positive, using the MPT, whereas 10 eyes were positive and 7 eyes were suspected positive using the DRPPT. The anterior chamber depth and angle opening distance 500 of the positive and suspected positive groups (positive group), using the MPT, were significantly less than those of the negative group (P=0.013, P=0.013, respectively). IT of the positive group, using the MPT, was significantly greater than the negative group, using the same test (P=0.003). The trabecular-iris space area 500 of the positive group was significantly less than the negative group, using both the MPT (Pchamber, narrower angle, and greater IT than those from the negative group. These results suggested that the MPT results better correlated with the anterior chamber angle configuration in eyes with primary angle closure, than the results using the DRPPT.

  1. The influence factors and management of anterior chamber gas bubble emergence during femtosecond flap creation for LASIK

    Directory of Open Access Journals (Sweden)

    Zhong-Ji Li

    2017-12-01

    Full Text Available AIM: To study the influence factors and management of anterior chamber gas bubble during femtosecond flap creation for laser-assisted in situ keratomileusis(LASIK. METHODS: Totally 9 671 eyes of 4 859 patients with femtosecond LASIK were included in this study. Preoperative, intraoperative and postoperative parameters of anterior chamber gas bubble patients were analyzed and compared. RESULTS: A total of 51 cases(0.53%occurred anterior chamber gas bubble during femtosecond flap creation. There was no statistical difference between uncorrected visual acuity of postoperative 1mo(-0.076±0.09and preoperative best corrected visual acuity(-0.08±0.04; t=-0.34,P=0.74. And 33 eyes(65%did not affect the pupil tracking, but there were 18 eyes(35%unable to track the pupil successfully. There was no statistical difference in uncorrected visual acuity of postoperative 1mo between trace group(-0.06±0.08and no trace group(-0.11±0.09; t=1.82, P=0.07. The highest incidence of anterior chamber gas bubble was at 9 point, followed by 3 point. There were no statistical differences in spherical equivalent refraction, corneal curvature, corneal diameter, anterior chamber volume, anterior chamber depth and intraoperative femtosecond laser energy between anterior chamber gas bubble eyes and the contralateral eyes(P>0.05. CONCLUSION: Anterior chamber gas bubble formation during femtosecond flap creation for LASIK is an uncommon event. It may affect the eye tracking. There is no obvious effect on early postoperative visual acuity if intraoperative disposed properly. The direct or indirect factors of anterior chamber gas bubble formation are unclear.

  2. Linguatula serrata in the anterior chamber of the eye

    Directory of Open Access Journals (Sweden)

    Muna Bhende

    2014-01-01

    Full Text Available We report a case of intraocular Linguatula in healthy young female who presented with a history of trivial trauma, dislocated lens, inflammation and secondary glaucoma. A mobile worm was seen in the anterior chamber. Pars plana lensectomy and vitrectomy was planned to remove both the cataractous lens and the parasite during which the worm disappeared from view but was later recovered from the cassette fluid. It was identified as the nymphal form of Linguatula serrata (tongue worm.

  3. Recurrent iridocyclitis due to cotton fiber in anterior chamber.

    Science.gov (United States)

    Joshi, Rajesh S

    2016-01-01

    Cotton is commonly used during ophthalmic surgical procedure. Cotton fibers may get attracted to the instruments due to electrostatic forces and become adhered to the surface. With the introduction of these instruments during the surgical procedure cotton fiber may get entry into the eye. In the literature they have been infrequently reported due to insignificant effect on the ocular structures. We present a case of recurrent iridocyclitis due to cotton fiber in the anterior chamber. Patient was relived of his symptoms after removal. A 78-year-old male presented with pain, redness and blurring of right eye vision since last six months. The patient had undergone phacoemulsification with implantation of hydrophilic intraocular lens (IOL) six years earlier. Postoperative follow up was uneventful from his records till last 6 months. Slit-lamp examination revealed a cotton fiber in the anterior chamber touching the endothelium. Keratic precipitates were seen on the endothelium. Removal of the cotton fiber resulted in subsidence of inflammation. We recommend use of plastic eye and trolley drapes, lint free instrument wipes and use of needle cap to support the globe during creation of side port while performing phacoemulsification instead of cotton buds to avoid entry of cotton fiber into the anterior chamber. © NEPjOPH.

  4. Late spontaneous resolution of a double anterior chamber post deep anterior lamellar keratoplasty

    Directory of Open Access Journals (Sweden)

    Andrea Passani

    2017-01-01

    Full Text Available A 31-year-old healthy male underwent deep anterior lamellar keratoplasty with big-bubble technique for treatment of keratoconus in his right eye. One week after surgery, he presented with detachment of the endothelium-Descemet complex with formation of a double anterior chamber, despite the apparent absence of an intraoperative Descemet membrane rupture. A subsequent intervention with the intent to relocate the corneal graft button was not effective, because the detachment appeared again one day later. The authors hypothesized that, at the time of the stromal dissection with big bubble technique, a small amount of air penetrated into the anterior chamber, creating a false pathway through the trabecular meshwork. The aqueous humor then penetrated the graft flowing through the false pathway, causing the endothelium-Descemet detachment. The persistence of that pathway, even after the intervention of graft repositioning, caused the failure of the latter procedure and persistence of the double chamber. We decided to wait and observe. The double anterior chamber spontaneously resolved in approximately three months.

  5. Dynamic changes in optic disc morphology, choroidal thickness, anterior chamber parameters, and intraocular pressure during Valsalva maneuver

    Directory of Open Access Journals (Sweden)

    Alper Mete

    Full Text Available ABSTRACT Purpose: To investigate the effects of the Valsalva maneuver (VM on optic disc morphology, choroidal thickness, and anterior chamber parameters. Methods: This prospective observational study included 60 eyes of 60 healthy subjects. The anterior chamber parameters, including central corneal thickness (CCT, anterior chamber depth (ACD, anterior chamber angle (ACA, anterior chamber volume (ACV, pupil diameter (PD, axial length (AL, subfoveal and peripapillary choroidal thickness, optic disc parameters, and intraocular pressure (IOP, were measured at rest and during VM. Results: VM did not have any significant influence on AL, subfoveal and peripapillary choroidal thickness, optic disc area, rim area, cup area, cup-to-disc area ratio, vertical cup-to-disc ratio, rim volume, cup volume, and nerve head volume measurements (for all; p >0.05. IOP and PD significantly increased during VM (for both; p <0.001. VM significantly decreased CCT, ACD, ACA, and ACV values (for all; p <0.001. Moreover, the optic nerve cup volume decreased and the horizontal cup-to-disc ratio significantly increased during VM (for both; p <0.05. Conclusions: VM may cause transient changes in IOP, optic disc morphology, and anterior chamber parameters.

  6. Maintenance of the anterior chamber during penetrating keratoplasty.

    Science.gov (United States)

    Kramer, S G; Stewart, H L

    1976-01-01

    A description of the author's (S.G.K.) technique for penetrating keratoplasty is provided. The salient features include corneal removal, storage, and corneal graft cutting procedures of Kaufman and his co-workers. In addition, a specially designed suturing contact lens is described which allows maintenance of the anterior chamber during penetrating keratoplasty. It is suggested that trauma to the all-important cornea endothelium can be minimized by application of this technique, because it significantly reduces the likelihood of endothelial trauma induced by mechanical contact of the endothelium with intraocular recipient structures during suturing.

  7. Ethnic difference of the anterior chamber area and volume and its association with angle width.

    Science.gov (United States)

    Wang, Dandan; Qi, Meng; He, Mingguang; Wu, Lingling; Lin, Shan

    2012-05-31

    To compare the anterior chamber area/volume (ACA/ACV) and their relationship with the drainage angle between adult Caucasians and Chinese. Study groups were comprised of four age- and sex-matched cohorts: American Caucasians, American Chinese, southern mainland Chinese, and northern mainland Chinese. All subjects were consecutively recruited from general ophthalmology clinics except for southern mainland Chinese participants who were drawn from an ongoing population-based study. Anterior segment optical coherence tomography (ASOCT) images were obtained under dark conditions. Customized software was used to analyze structural indices including ACA/ACV, angle opening distance (AOD), anterior chamber depth (ACD), anterior chamber width (ACW), lens vault (LV), corneal arc depth (CAD), iris thickness (IT), iris curvature (ICurv), and iris area (IArea). Data from 121, 124, 121, and 120 participants were obtained of American Caucasians, American Chinese, and southern and northern mainland Chinese, respectively. After multiple linear regression analysis, adjusting for age, sex, pupil diameter (PD), and axial length (AL), ACA/ACV was positively associated with ACD, ACW, CAD, and corneal radius of curvature (CR) but negatively related with ICurv and IArea. Ethnic Chinese had significantly smaller ACA (β = -0.18, P = 0.022) and ACV (β = -3.9, P = 0.001) than Caucasians. ACV contributes the most to AOD variation for both Chinese (standardized regression coefficient [SRC] = 0.47, P ACV independent of ACD, ACW, ICurv, IArea, PD, CR, and AL. ACA/ACV is the most prominent contributor to angle width variation for both Chinese and Caucasians in this study.

  8. The phakic intraocular lens implant: in-depth focus on posterior chamber phakic IOLs.

    Science.gov (United States)

    Zaldivar, R; Ricur, G; Oscherow, S

    2000-02-01

    Phakic Intraocular surgery has come a long way in the past 20 years, especially in the evolution of posterior chamber phakic intraocular lenses (PC PIOLs). Clinical trials worldwide are showing acceptable results concerning efficacy, predictability, stability, and safety. PC PIOLS are proving to be a promising option for patients with high and extreme ametropia who cannot benefit from conventional corneal refractive procedures. This article provides an in-depth examination of PC PIOLs, their origin and evolution, and the results of past and current clinical studies. Reports of historical importance and studies published since the 1990s in peer-reviewed journals, textbooks, and monthly eye magazines, as well as Food and Drug Administration preliminary clinical findings, are reviewed. Anterior chamber phakic intraocular lenses are mentioned briefly.

  9. Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles.

    Science.gov (United States)

    Grewal, D S; Brar, G S; Jain, R; Grewal, S P S

    2011-05-01

    To compare the performance of anterior chamber volume (ACV) and anterior chamber depth (ACD) obtained using Scheimpflug imaging with angle opening distance (AOD500) and trabecular-iris space area (TISA500) obtained using spectral domain anterior segment optical coherence tomography (SD-ASOCT) in detecting narrow angles classified using gonioscopy. In this prospective, cross-sectional observational study, 265 eyes of 265 consecutive patients underwent sequential Scheimpflug imaging, SD-ASOCT imaging, and gonioscopy. Correlations between gonioscopy grading, ACV, ACD, AOD500, and TISA500 were evaluated. Area under receiver operating characteristic curve (AUC), sensitivity, specificity, and likelihood ratios (LRs) were calculated to assess the performance of ACV, ACD, AOD500, and TISA500 in detecting narrow angles (defined as Shaffer grade ≤1 in all quadrants). SD-ASOCT images were obtained at the nasal and temporal quadrants only. Twenty-eight eyes (10.6%) were classified as narrow angles on gonioscopy. ACV correlated with gonioscopy grading (PACV correlated with TISA500 for nasal (r=0.135, P=0.029) and temporal (P=0.160, P=0.009) quadrants and also with AOD500 for nasal (r=0.498, PACV (AUC=0.935; 95% confidence interval (CI) =0.898-0.961) performed similar to ACD (AUC=0.88, P=0.06) and significantly better than AOD500 nasal (AUC=0.761, P=0.001), AOD500 temporal (AUC=0.808, PACV had 90% sensitivity and 88% specificity for detecting narrow angles. Positive and negative LRs for ACV were 8.63 (95% CI=7.4-10.0) and 0.11 (95% CI=0.03-0.4), respectively. ACV measurements using Scheimpflug imaging outperformed AOD500 and TISA500 using SD-ASOCT for detecting narrow angles.

  10. Steeper Iris Conicity Is Related to a Shallower Anterior Chamber: The Gutenberg Health Study

    Science.gov (United States)

    Pfeiffer, Norbert; Nickels, Stefan; Schulz, Andreas; Wild, Philipp S.; Blettner, Maria; Lackner, Karl; Beutel, Manfred E.; Münzel, Thomas; Vossmerbaeumer, Urs

    2017-01-01

    Purpose To report the distribution of iris conicity (steepness of the iris cone), investigate associated factors, and test whether pseudophakia allows the iris to sink back. Methods A population-based cross-sectional study was carried out. Ophthalmological examination including objective refraction, biometry, noncontact tonometry, and Scheimpflug imaging (Pentacam®, Oculus) was performed including automated measurement of iris conicity. 3708 phakic subjects, 144 subjects with bilateral and 39 subjects with unilateral pseudophakia were included. Multivariable analyses were carried out to determine independently associated systemic and ocular factors for iris conicity in phakic eyes. Results Mean iris conicity was 8.28° ± 3.29° (right eyes). Statistical analysis revealed associations between steeper iris conicity and shallower anterior chamber depth, thicker human lens and higher corneal power in multivariable analysis, while older age was related to a flatter iris conicity. Refraction, axial length, central corneal thickness, pupil diameter, and intraocular pressure were not associated with iris conicity. Pseudophakia resulted in a 5.82° flatter iris conicity than in the fellow phakic eyes. Conclusions Associations indicate a correlation between iris conicity with risk factors for angle-closure, namely, shallower anterior chamber depth and thicker human lens. In pseudophakic eyes, iris conicity is significantly lower, indicating that cataract surgery flattens the iris. PMID:29085672

  11. Steeper Iris Conicity Is Related to a Shallower Anterior Chamber: The Gutenberg Health Study

    Directory of Open Access Journals (Sweden)

    Alexander K. Schuster

    2017-01-01

    Full Text Available Purpose. To report the distribution of iris conicity (steepness of the iris cone, investigate associated factors, and test whether pseudophakia allows the iris to sink back. Methods. A population-based cross-sectional study was carried out. Ophthalmological examination including objective refraction, biometry, noncontact tonometry, and Scheimpflug imaging (Pentacam®, Oculus was performed including automated measurement of iris conicity. 3708 phakic subjects, 144 subjects with bilateral and 39 subjects with unilateral pseudophakia were included. Multivariable analyses were carried out to determine independently associated systemic and ocular factors for iris conicity in phakic eyes. Results. Mean iris conicity was 8.28° ± 3.29° (right eyes. Statistical analysis revealed associations between steeper iris conicity and shallower anterior chamber depth, thicker human lens and higher corneal power in multivariable analysis, while older age was related to a flatter iris conicity. Refraction, axial length, central corneal thickness, pupil diameter, and intraocular pressure were not associated with iris conicity. Pseudophakia resulted in a 5.82° flatter iris conicity than in the fellow phakic eyes. Conclusions. Associations indicate a correlation between iris conicity with risk factors for angle-closure, namely, shallower anterior chamber depth and thicker human lens. In pseudophakic eyes, iris conicity is significantly lower, indicating that cataract surgery flattens the iris.

  12. Effects of hemodialysis on corneal and anterior chamber morphometry and intraocular pressure in patients with end-stage renal disease

    Directory of Open Access Journals (Sweden)

    Mehtap Caglayan

    Full Text Available ABSTRACT Purpose: To evaluate the effects of hemodialysis (HD on corneal and anterior chamber morphometry, as well as intraocular pressure (IOP in patients with end-stage renal disease. Methods: Fifty right eyes were examined 30 minutes before and after HD. IOP was measured with a Goldmann applanation tonometer, and Ehlers' formula was used to calculate the corrected IOP values. The central corneal thickness (CCT, corneal volume (CV, keratometric values, anterior chamber depth (ACD, aqueous depth (AQD, anterior chamber volume (ACV, and anterior chamber angle (ACA in the nasal and temporal quadrants were measured with a Sirius anterior segment analysis system. Blood urea nitrogen levels, body mass, and systolic and diastolic arterial pressure were also measured before and after HD. Results: The mean age was 60.80 ± 13.38 (range: 35-80 years. The mean uncorrected and corrected IOP values decreased from 18.06 ± 3.91 and 18.31 ± 4.83 mmHg to 16.94 ± 3.87 and 16.95 ± 4.74 mmHg after HD, respectively (p=0.011 and p=0.003, respectively. The mean CCT decreased from 536.38 ± 24.73 to 533.18 ± 27.25 µm (p=0.002, and the mean CV decreased from 57.52 ± 3.15 to 55.68 ± 3.55 mm³ (p0.05 for all values. There were no significant correlations between the ocular and systemic parameters (p>0.05 for all correlations. Conclusions: Uncorrected IOP, corrected IOP, CCT, and CV values decreased after HD, whereas the anterior chamber morphometry values remained similar between the measurements performed before and after HD.

  13. Measurement of early changes in anterior chamber morphology after cataract extraction measured by anterior segment optical coherence tomography.

    Science.gov (United States)

    Kasai, Kozue; Takahashi, Genichiro; Kumegawa, Koichi; Dogru, Murat

    2015-10-01

    To evaluate the serial changes in anterior chamber depth (ACD) and angle parameters early after cataract surgery using anterior segment optical coherence tomography (ASOCT). This was a retrospective chart review, case-control study; 150 eyes of 106 patients who underwent cataract surgery. Based on ACD and angle findings, the eyes were classified into two groups, open-angle eyes (87 eyes) and narrow-angle eyes (63 eyes). ASOCT was used to measure ACD and angle parameters (angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle (TIA [1]). Serial changes in each group were measured before and 1 day, 1 week, and 1 month after cataract surgery, and the differences between the two groups were compared. ACD and all angle parameters in both groups at each examination time after cataract surgery were significantly different from the preoperative values (p < 0.01). In addition, all angle parameters significantly differed between the two groups at each examination time after cataract surgery (p < 0.001). However, ACD after surgery was not significantly different, irrespective of ACD before surgery. ACD and TIA500 both showed significantly greater changes from before surgery to 1 day after surgery in narrow-angle eyes compared to open-angle eyes (p < 0.001). Cataract surgery increases ACD and all angle parameters early after the surgery. However, the degree of angle widening in narrow-angle eyes was not as much as that in open-angle eyes, suggesting that factors other than the lens influence the angle closure.

  14. The effect of internal fixation lamp on anterior chamber angle width measured by anterior segment optical coherence tomography.

    Science.gov (United States)

    Nakamine, Sakari; Sakai, Hiroshi; Arakaki, Yoshikuni; Yonahara, Michiko; Kaiya, Tadayoshi

    2018-01-01

    To study the effect of the internal fixation lamp on anterior chamber width measured by anterior segment optical coherence tomography. In a prospective cross sectional observational study, consecutive 22 right eyes of 22 patients (4 men and 18 women) with suspected primary angle closure underwent swept source domain anterior segment optical coherence tomography (AS-OCT), (CASIA SS-1000, Tomey, Nagoya, Japan). Anterior chamber parameters of angle opening distance (AOD), trabecular-iris angle (TIA), angle recess area (ARA) at 500 or 750 µm from scleral spur and pupil diameter were measured by AS-OCT in a three-dimensional mode in 4 quadrants (superior, inferior, temporal and nasal) in dark room setting both with and without internal fixation lamp. Anterior segment parameters of AOD 500 in superior, inferior and temporal quadrants, AOD 750 at superior and nasal, TIA 500 at superior, and inferior and TIA 750 at superior and nasal, and ARA 500 or 750 at superior and inferior with internal fixation lamp were greater and the pupil diameter was significantly (all P chamber angle is narrow but open, it is recommended that the internal fixation lamp be turned off to ensure a clear indication as to whether the angle is open or closed in the dark.

  15. Retrospective Study of Vitreous Tap Technique Using Needle Aspiration for Management of Shallow Anterior Chamber during Phacoemulsification

    Directory of Open Access Journals (Sweden)

    Ashraf Ahmed Nossair

    2017-01-01

    Full Text Available Purpose. To evaluate the technique of vitreous tap using needle aspiration for management of anterior chamber shallowness during phacoemulsification. Methods. A retrospective study included 26 eyes of 17 patients who underwent phacoemulsification in which vitreous tap was performed using a 27-gauge needle attached to a 5 ml syringe, inserted 3.5 mm from the limbus to aspirate 0.2 ml of liquefied vitreous if a cohesive (OVD failed to sufficiently deepen the anterior chamber. Results. Preoperative anterior chamber depth was 2.31 ± 0.26 mm, axial length was 21.7 ± 0.67 mm, lens thickness was 4.5 ± .19 mm, and cataract grade was 3.77 ± 1.4. Preoperative CDVA in LogMAR units was 0.98 ± 0.75. Coexisting angle closure glaucoma was present in 7 patients (26.92% preoperatively. Vitreous needle tap was successful in vitreous removal on the first attempt in 26 eyes (100%. Postoperative follow-up period was 22.88 ± 10.24 (4–39 months. The final postoperative CDVA in LogMAR units was 0.07 ± 0.1, while the final postoperative IOP was 16.54 ± 1.45 mmHg. No complications related to vitreous tap were noted. Conclusion. Vitreous needle tap is a simple, cost-effective, and safe technique for management of shallow anterior chamber in phacoemulsification.

  16. Single session, intrauser repeatability of anterior chamber biometric and corneal pachy-volumetric parameters using a new Scheimpflug+Placido device.

    Science.gov (United States)

    Prakash, Gaurav; Srivastava, Dhruv

    2016-01-01

    To analyze single session, intrauser reliability of a Scheimpflug device for anterior chamber (AC) and corneal parameters. In this observational study, 100 normal candidates underwent Scheimpflug analysis with Sirius 3D Rotating Scheimpflug Camera and Topography System (Costruzione Strumenti Oftalmici, Italy). Two scans in dark room conditions were performed by the same experienced user. The candidates were asked to keep both eyes closed for 5min before the scans. Exclusion criteria were previous ocular surgery, corneal scarring and anterior segment/posterior segment anomalies. Only the right eyes were used for the analysis. Both corneal (central, minimum, and apical thickness, volume, horizontal visible iris diameter, and apical curvature) and anterior chamber (volume, depth, angle, horizontal diameter) measurements were evaluated. There was no difference in the means of repeated measurements (p>0.05, ANOVA). Intraclass correlations between the measures were high and ranged from 0.995-0.997 for corneal to 0.964-0.997 for anterior chamber (AC) parameters. The precision of repeatability measures (1.96×Sw) was approximately 5μ for the central and minimum corneal thickness, 8μ for the apical corneal thickness, 0.06mm for AC (anterior chamber) depth and less than 2° for the AC angle. Sirius Scheimpflug system has high repeatability for both corneal and AC parameters in normal eyes. Copyright © 2015 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  17. Cystercercus larva in the anterior chamber of the eye of a 7year o

    African Journals Online (AJOL)

    user

    infestation should be considered when children present with features of ocular inflammation. INTRODUCTION ... dogs (T. solium, Echinococcus), cows (T. saginata), rodents. (Hymenolepsis), and fish (Diphyllobothrium ... infestation while involvement of the anterior chamber is said to be unusual. 2,3. Symptoms of ocular ...

  18. Hematoporphyrin derivative photoradiation treatment of experimental malignant melanoma in the anterior chamber of the rabbit

    NARCIS (Netherlands)

    Franken, K. A.; van Delft, J. L.; Dubbelman, T. M.; de Wolff-Rouendaal, D.; Oosterhuis, J. A.; Star, W. M.; Marijnissen, H. P.

    1985-01-01

    The effects of Hematoporphyrin Derivative Photoradiation Therapy (HpD-PRT) on Greene's amelanotic melanoma implanted into the anterior chamber of rabbits have been examined by biomicroscopy, fluorescein angiography and histopathology. The tumors were irradiated 24 hours after injection of HpD when

  19. Iris-fixated anterior chamber phakic intraocular lens for myopia moves posteriorly with mydriasis.

    NARCIS (Netherlands)

    Cruysberg, L.P.J.; Doors, M.; Berendschot, T.T.; Brabander, J. De; Webers, C.A.; Nuijts, R.M.

    2009-01-01

    PURPOSE: To elucidate the physiological characteristics of eyes implanted with iris-fixated anterior chamber phakic intraocular lenses (pIOLs), which are increasingly being used for the correction of higher myopic and hyperopic refractive errors. METHODS: In a case series of 20 patients (39 eyes),

  20. Upregulation of CD94 on CD8+T Cells in Anterior Chamber Immune Deviation

    NARCIS (Netherlands)

    He, H.; Yang, P.; Jiang, L.; Zhang, J.; Zhao, Changlin; Chen, L.; Lin, X.; Zhou, H.; Kijlstra, A.

    2008-01-01

    Background CD8+ regulatory T cells (Treg) have been considered to be involved in a model of ocular-induced tolerance, known as anterior chamber-associated immune deviation (ACAID). The phenotype and characteristics of CD8+Treg in ACAID remain only poorly understood. Recent studies have reported that

  1. Changes in ocular biometry and anterior chamber parameters after pharmacologic mydriasis and peripheral iridotomy in primary angle closure suspects

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Razeghinejad

    2016-07-01

    Conclusions: This study showed no change in the ocular biometric and anterior chamber parameters including iridocorneal angle after PI and/or pharmacologic mydriasis except for increments in anterior chamber volume. This factor has the potential to be used as a numerical proxy for iris position in evaluating and monitoring patients with primary angle closure suspects after PI.

  2. OVA-specific CD8(+)T cells do not express granzyme B during anterior chamber associated immune deviation

    NARCIS (Netherlands)

    Ren, Y.; Yang, P.; Li, B.; Gao, Y.; Zhou, H.; Huang, X.; Zhu, L.; Kijlstra, A.

    2006-01-01

    To examine antigen (Ag)-specific CTL response during anterior chamber associated immune deviation (ACAID). Methods OVA or OVA257-264 peptide was injected into the anterior chamber (AC) of C57BL/6 mice. There were 16 mice in each ACAID group induced with OVA or OVA257-264 peptide. The mice were

  3. Correlation between intraocular pressure and the biometric structure of the anterior chamber in patients of chronic renal failure with hemodialysis

    Directory of Open Access Journals (Sweden)

    Zhi-Ying Yu

    2017-02-01

    Full Text Available AIM: To investigate the correlation between intraocular pressure(IOPchanges pre- and post-hemodialysis(HDand the biometric structure of the anterior chamber in patients of chronic renal failure. METHODS: Fifty-two patients(take right eye as study onewith hemodialysis that were diagnosed with chronic renal failure by nephrology in our hospital from January 2015 to December 2015 were collected. Fifty-two eyes were divided into four groups based on Shaffer classification combined with ultrasound biomicroscopy(UBMand gonioscopy manifestations: wide angle group, narrow angle group, extremely narrow group and close angle group. Venous blood was collected to get plasma colloid osmotic pressure before HD and within 60s after HD. IOP was measured with rebound intraocular pressure gauge in a supine positon approximately 30min before starting HD, 2h after HD begin and approximately 30min after HD ending. Approximately 30min before and after HD, central corneal thickness was measured with corneal endothelial cell counter, central anterior chamber depth and lens thickness were taken by A scan, angle opening distance, trabecular iris angle, iris thickness and ciliary body thickness were measured by UBM. RESULTS: Plasma osmotic pressure reduced after HD, the difference was statistically significant(t=3.04, PF=41.69, PPPF=6.44, PPt=2.61, PCONCLUSION: The influence of hemodialysis on IOP is related to the biometric structure of the anterior chamber. And extremely narrow angle is risk factor of elevated IOP during hemodialysis, narrow angle may be a risk factor. While patients with wide angle is relatively safe. We suggest to take ocular examination as early as possible for patients with hemodialysis, and focus on patients with narrow angle.

  4. The change of magma chamber depth in and around the Baekdu Volcanic area from late Cenozoic

    Science.gov (United States)

    Lee, S. H.; Oh, C. W.; Lee, Y. S.; Lee, S. G.; Liu, J.

    2016-12-01

    The Baekdu Volcano is a 2750m high stratovolcanic cone resting on a basaltic shield and plateau and locates on the North Korea-China border. Its volcanic history can be divided into four stages (from the oldest to the youngest): (i) preshield plateau-forming eruptions, (ii) basalt shield formation, (iii) construction of a trachytic composite cone, and (iv) explosive ignimbrite forming eruptions. In the First stage, a fissure eruption produced basalts from the Oligocene to the Miocene (28-13 Ma) forming preshield plateau. Fissure and central eruptions occurred together during the shield-forming eruptions (4.21-1.70 Ma). In the third stage, the trachytic composite volcano formed during the Pleistocene (0.61-0.09 Ma). In this stage, magma changed to an acidic melt. The latest stage has been characterized by explosive ignimbrite-forming eruptions during the Holocene. The composite volcanic part consists of the Xiaobaishan, Lower, Middle and Upper Trachytes with rhyolites. The whole rock and clinopyroxene in basalts, trachytic and rhyolite, are analyzed to study the depth of magma chambers under the Baekdu Volcano. From the rhyolite, 9.8-12.7kbar is obtained for the depth of magma chamber. 3.7-4.1, 8.9-10.5 and 8.7 kbar are obtained from the middle, lower and Xiaobaishan trachytes. From the first and second stage basalts, 16.9-17.0 kbar and 14-14.4kbar are obtained respectively. The first stage basalt give extrusive age of 11.98 Ma whereas 1.12 and 1.09 Ma are obtained from the feldspar and groundmass in the second stage basalt. The Xiaobaishan trachyte and rhyolite give 0.25 and 0.21 Ma whereas the Middle trachyte gives 0.07-0.06 Ma. These data indicate that the magma chambers of the first and second stage basalts were located in the mantle and the magma chamber for the second stage basalt may have been underplated below continental crust. The Xiaobisan trachyte and rhyolite originated from the magma chamber in the depth of ca. 30-40 km and the Middle trachyte

  5. Acanthamoeba keratitis with granulomatous reaction involving the stroma and anterior chamber.

    Science.gov (United States)

    Mietz, H; Font, R L

    1997-02-01

    Most cases of granulomatous reaction to Descemet membrane are caused by disciform herpes simplex and mycotic keratitis. To our knowledge, a clinicopathologic report of Acanthamoeba species infection has not been documented. We used standard histopathologic techniques, including light microscopy with special stains and indirect immunofluorescence. A granulomatous reaction with many multinucleated giant cells, some of which engulfed cysts of Acanthamoeba species, was present in the posterior corneal stroma and anterior chamber along the plane of Descemet membrane. A severe, acute, suppurative inflammatory response and areas of stromal necrosis also were present. The diagnosis of Acanthamoeba castellanii was confirmed by immunofluorescent studies. A granulomatous reaction to Descemet membrane and/or the corneal stroma may represent a specific tissue response to various infectious agents. Keratitis caused by Acanthamoeba species may be added to herpes simplex stromal keratitis and mycotic keratitis as a causative organism capable of producing a granulomatous reaction involving the stroma and anterior chamber.

  6. [Comparison of anterior chamber angle examination by UBM, SL-OCT and gonioscopy].

    Science.gov (United States)

    Liu, Rui-jue; Wang, Men; Xia, Wen-tao; Yu, Xiao-ying; Chen, Jie-min; Zhou, Shu; Peng, Shu-ya; Liu, Dong-mei

    2014-08-01

    To compare the agreement of anterior chamber angle examination by ultrasound biomicroscope (UBM), slit lamp optical coherence tomography (SL-OCT), and gonioscopy in angle recession and angle closure. The anterior chamber angle was measured with UBM, SL-OCT and gonioscopy in turns for temporal, nasal, superior and inferior quadrant in the same dark room. The results were compared with the agreement of the three methods in angle recession and angle closure by χ2 test and Kappa test. There were no statistically significant differences of the three methods in testing angle closure and angle recession (P>0.05). The consistency of UBM and gonioscopy was better (Kappa value of 0.882) than that of SL-OCT and gonioscopy (Kappa value of 0.624). When testing angle recession, UBM is better than SL-OCT with gonioscopy as the standard. When testing angle closure, UBM, SL-OCT and gonioscopy have good agreement.

  7. Effect of topiramate on choroidal thickness and anterior chamber parameters in the treatment of patients with migraine.

    Science.gov (United States)

    Gok, Mustafa; Ozdemir, Ozdemir

    2017-12-01

    To investigate the effects of topiramate on choroidal thickness and anterior chamber parameters using optical coherence tomography in the treatment of patients with migraine. A total of 22 eyes of 22 adults (12 females, 10 males) diagnosed with migraine and scheduled to topiramate treatment for pain control were recruited in this prospective study. Choroidal thickness (CT), anterior chamber depth (ACD), anterior chamber angle (ACA), spherical refractive equivalent (SphEq) and intraocular pressure (IOP) measurements were recorded at baseline (prior the topiramate therapy), first and second month visits for the statistical analysis. One-way ANOVA with repeated measures test was used for the statistical evaluation. Mean age of the patients was 40.2 ± 6.5 years. Mean CT at central fovea was 324 ± 47 μm initially, 341 ± 45 μm in the first month and 344 ± 46 μm in the second month, thus first and second month measures were significantly higher than base values (p < 0.001). There was also a slight increase in IOP values among baseline (15.5 ± 2.4 mmHg) and follow-up visits (17.5 ± 2.6 mmHg, 19.0 ± 3.3 mmHg, respectively, ` p = 0.001). Baseline ACD (3.66 ± 0.22 mm) measures significantly decreased at the first month (3.63 ± 0.22 mm) and second month (3.62 ± 0.22 mm, p = 0.009). Also, a significant reduction was detected in the first (36.2 ± 4.9°) and second month (35.9 ± 5.1°) ACA measures comparing with baseline (39.1 ± 5.1°, p = 0.05). A significant myopic shift was determined in the first and second month SphEq values (-0.08 ± 0.6, -0.10 ± 0.6, respectively, p = 0.05). The study revealed increased CT and altered anterior chamber parameters and IOP due to topiramate therapy. Therefore, the patients using topiramate should be carefully monitored by an ophthalmologist considering the possible side effects.

  8. Nitric oxide levels in the anterior chamber of vitrectomized eyes with silicon oil

    Directory of Open Access Journals (Sweden)

    Paulo Escarião

    2013-10-01

    Full Text Available PURPOSE: To investigate the nitric oxide levels in the anterior chamber of eyes who underwent pars plana vitrectomy (PPV with silicone oil. METHODS: Patients who underwent PPV with silicon oil injection, from february 2005 to august 2007, were selected. Nine patients (nine eyes participated in the study (five women and four men. Nitric oxide concentration was quantified after the aspiration of aqueous humor samples during the procedure of silicon oil removal. Data such as: oil emulsification; presence of oil in the anterior chamber; intraocular pressure and time with silicone oil were evaluated. Values of p <0.05 were considered to be statistically significant. RESULTS: A positive correlation between nitric oxide concentration and time with silicon oil in the vitreous cavity (r=0.799 was observed. The nitric oxide concentration was significantly higher (p=0.02 in patients with silicon oil more than 24 months (0.90µmol/ml ± 0.59, n=3 in the vitreous cavity comparing to patients with less than 24 months (0.19µmol/ml ± 0.10, n=6. CONCLUSION: A positive correlation linking silicone oil time in the vitreous cavity with the nitric oxide concentration in the anterior chamber was observed.

  9. Differences in baseline dark and the dark-to-light changes in anterior chamber angle parameters in whites and ethnic Chinese.

    Science.gov (United States)

    Wang, Dandan; Chiu, Cynthia; He, Mingguang; Wu, Lingling; Kao, Andrew; Lin, Shan

    2011-12-09

    To assess the anterior chamber drainage angle width in the dark and the dark-to-light change (Δ) between Caucasians and Chinese aged 40 years and older. The study groups comprised four age- and sex-matched cohorts: American Caucasians, American Chinese, southern mainland Chinese, and northern mainland Chinese. Anterior segment optical coherence tomography (ASOCT) images of the anterior chamber angles were obtained under both light and dark conditions. The parameters analyzed included angle opening distance (AOD), angle recess area (ARA), and trabecular-iris space area (TISA). Data were obtained from 121, 124, 121, and 120 participants who were American Caucasians, American Chinese, and southern and northern mainland Chinese, respectively. In a multiple linear regression analysis, adjusted for age, sex, refractive status, pupil size, lens location, and anterior chamber depth (ACD) and width (ACW), the ethnic Chinese had significantly smaller ARAs (regression coefficient, β = -0.06, P dark-to-light change analysis, the independent associations between angle width and iris thickness (IT) and iris curvature (ICurv) were identified only in the Chinese. Compared with the Caucasians, the ethnic Chinese had smaller ARA and TISA, but greater dark-to-light changes in AOD and TISA, independent of refractive status and overall ocular anterior segment dimensions.

  10. PARS PLANA VITRECTOMY WITH ANTERIOR CHAMBER VERSUS GORE-TEX SUTURED POSTERIOR CHAMBER INTRAOCULAR LENS PLACEMENT: LONG-TERM OUTCOMES.

    Science.gov (United States)

    Khan, M Ali; Gupta, Omesh P; Pendi, Kasim; Chiang, Allen; Vander, James; Regillo, Carl D; Hsu, Jason

    2018-01-16

    To compare clinical outcomes of combined pars plana vitrectomy (PPV) with anterior chamber intraocular lens (ACIOL) placement versus scleral fixation of a posterior chamber intraocular lens (PCIOL) using Gore-Tex suture. Retrospective, interventional case series of eyes undergoing combined PPV and IOL placement for retained lens material, aphakia, or dislocated IOL. Eyes with history of amblyopia, corneal opacity, retinal, or optic nerve disease were excluded. Outcome measures were change in visual acuity and occurrence of postoperative complications with minimum follow-up of 1 year. Sixty-three eyes of 60 patients were identified. Thirty-three eyes underwent combined PPV and ACIOL placement and 30 eyes underwent combined PPV and scleral fixation of a PCIOL using Gore-Tex suture. Mean follow-up was 502 ± 165 days (median 450, range 365-1,095 days). In the ACIOL group, mean visual acuity improved from 20/914 preoperatively to 20/50 postoperatively (P Gore-Tex suture were well tolerated. The techniques resulted in similar visual outcomes at minimum follow-up of 1 year.

  11. Flat Anterior Chamber after Trabeculectomy in Secondary Angle-Closure Glaucoma with BEST1 Gene Mutation: Case Series.

    Directory of Open Access Journals (Sweden)

    Yimin Zhong

    Full Text Available Trabeculectomy has been regarded as a mainstay of initial treatment in eyes of angle closure glaucoma (ACG with peripheral anterior synechia > 180° in the Chinese population while its efficacy in secondary ACG with BEST1 gene mutation remains unclear. We set out to investigate the treatment outcome of trabeculectomy for secondary ACG in a group of patients with autosomal recessive bestrophinopathy (ARB.In this retrospective case series study, 8 secondary ACG patients with ARB and their 4 recruited family members underwent a thorough ophthalmic examination including best-corrected visual acuity, Goldmann applanation tonometry, gonioscopy, and fundus examinations. Ultrasound biomicroscopy, optical coherence tomography (OCT, ultrasound A-scan, B-scan, electro-oculography (EOG, Humphrey perimetry, fundus photography, fundus fluorescein angiography (FFA and indocyanine green angiography (ICGA were also performed. Blood samples were obtained in the patients and their available family members to analyze the variants of the BEST1 gene. Trabeculectomy was performed in the 8 patients (15 eyes.The age of onset varied from 13 to 38 years. The average axial length (AL of the affected eyes was 21.82 ± 0.92 mm and the average anterior chamber depth (ACD was 2.19 ± 0.29 mm. There was marked axial shallowing of the anterior chamber in all 15 eyes after trabeculectomy, and was not improved with potent mydriatics. The IOP was elevated in 3 eyes. Variable degree of yellowish subretinal deposits was observed in the posterior retina. The FFA showed punctuate or patched hyperfluorescence suggesting retinal pigment epithelium impairment. The ICGA demonstrated dilatation of choroidal vessels. The OCT revealed diffused neuroretinal detachment in the posterior and midperipheral retina, with intraretinal fluid collections, and hyperreflective subretinal accumulations. The average subfoveal choroidal thickness of the patients was 382.36 ± 80.09 μm. All the patients and

  12. Incidence and Outcomes of Anterior Chamber Gas Bubble during Femtosecond Flap Creation for Laser-Assisted In Situ Keratomileusis

    Directory of Open Access Journals (Sweden)

    Sloan W. Rush

    2015-01-01

    Full Text Available Purpose. To report the incidence and outcomes of anterior chamber gas bubble formation during femtosecond laser flap creation for laser-assisted in situ keratomileusis (LASIK. Methods. The charts of 2,886 consecutive eyes that underwent femtosecond LASIK from May 2011 through August 2014 were retrospectively reviewed. The incidence, preoperative characteristics, intraoperative details, and postoperative outcomes were analyzed in subjects developing anterior chamber gas bubble formation during the procedure. Results. A total of 4 cases (0.14% developed anterior chamber gas bubble formation during femtosecond laser flap creation. In all four cases, the excimer laser was unable to successfully track the pupil immediately following the anterior chamber bubble formation, temporarily postponing the completion of the procedure. There was an ethnicity predilection of anterior chamber gas formation toward Asians (p=0.0055. An uncorrected visual acuity of 20/20 was ultimately achieved in all four cases without further complications. Conclusions. Anterior chamber gas bubble formation during femtosecond laser flap creation for LASIK is an uncommon event that typically results in a delay in treatment completion; nevertheless, it does influence final positive visual outcome.

  13. Association of biometric factors with anterior chamber angle widening and intraocular pressure reduction after uneventful phacoemulsification for cataract.

    Science.gov (United States)

    Huang, Guofu; Gonzalez, Eduardo; Lee, Roland; Chen, Yi-Chun; He, Mingguang; Lin, Shan C

    2012-01-01

    To evaluate anterior chamber biometric factors associated with the degree of angle widening and intraocular pressure (IOP) reduction after phacoemulsification. University of California, San Francisco, California, USA. Case series. Anterior chamber parameters obtained by anterior segment coherence tomography were compared preoperatively and 3 months postoperatively. Measurements included the angle opening distance 500 μm anterior to the scleral spur (AOD500), trabecular-iris space area 500 μm from the scleral spur (TISA500), iris curvature (I-Curv), anterior chamber angle (ACA), trabecular-iris space area, anterior chamber volume, anterior chamber width, and lens vault (LV). The study enrolled 73 eyes. The mean patient age was 77.45 years ± 7.84 (SD); 65.75% of patients were women. From preoperatively to 3 months postoperatively, the mean AOD500 increased significantly (0.254 ± 0.105 to 0.433 ± 0.108 mm) and the mean IOP decreased significantly (14.97 ± 3.35 to 12.62 ± 3.37 mm Hg) (Pbiometric factors. Preoperative LV appears to be a significant factor in angle widening and IOP reduction after phacoemulsification. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Spontaneous resolution of double anterior chamber with perforation of Descemet′s membrane in deep anterior lamellar keratoplasty

    Directory of Open Access Journals (Sweden)

    Arvind Venkatraman

    2012-01-01

    Full Text Available Deep anterior lamellar keratoplasty (DALK using Dr. Anwar′s big bubble technique was performed for a patient with granular dystrophy. Intraoperatively, a perforation of the Descemet′s membrane (DM was noted inferonasally. Though the surgery was completed, the donor graft appeared to have an intact endothelium, which was inadvertently left behind by the surgeon. Intraoperatively, there was a perforation of inferonasal DM and surgery was completed by inadvertently placing a donor with an intact endothelium. Postoperatively the patient presented with a complete DM detachment and a resultant double anterior chamber (DAC. In spite of two attempts at an air tamponade on the first and fifth post operative days, the DAC still persisted. Surprisingly, during the 6 th week follow up visit, there was a complete resolution of the DAC as well as total recovery of vision. This interesting case clearly exemplifies that, in spite of failed attempts at air tamponade, a DM detachment and a DAC due to DM perforation following a DALK procedure can resolve spontaneously with good visual outcome.

  15. [Experimental hypertony caused by obstruction of the anterior chamber angle ab interno (author's transl)].

    Science.gov (United States)

    Maguritsas, N; Vikas, C; Theodossiadis, G; Vergados, I; Velissaropoulos, P

    1976-07-01

    In 30 rabbits, separated into 3 groups (A, B and C), the entire area (A), three quarters (B) half of the anterior chamber angle (C) was experimentally obstructed by means of a homologous scleral graft. In groups A and B a statistically significant change of the intraocular pressure and of the cornea diameter was shown as compared with the control eye and group C. This change is due to the obstructed area of the angle. The increased intraocular pressure lasted for some months. The graft was well tolerated by the tissue of the angle and the obstruction of the angle was total, as was confirmed by means of the histological preparations.

  16. Primary anterior chamber intraocular lens for the treatment of severe crystalline lens subluxation.

    Science.gov (United States)

    Hoffman, Richard S; Fine, I Howard; Packer, Mark

    2009-10-01

    Subluxated cataractous and clear lenses are commonly treated by limbal or pars plana lensectomy followed by primary or secondary intraocular lens (IOL) implantation. Adjunctive capsular prosthetic devices have facilitated lens removal and IOL centration in these challenging cases but have also added complexity and potential complications to the procedure. Although crystalline lens extraction may be required to clear the visual axis in mild to moderate lens subluxations, we propose insertion of a primary anterior chamber IOL without lens extraction in severe subluxations when the eye is optically aphakic or can be made functionally aphakic following neodymium:YAG laser zonulysis. Two cases demonstrating this approach are presented.

  17. Loa loa in the anterior chamber of the eye: A case report

    Directory of Open Access Journals (Sweden)

    Barua P

    2005-01-01

    Full Text Available An unusual case of loiasis from Assam is reported here. Loa loa is a subcutaneous filarial parasite of man and is transmitted to humans by chrysops flies. The patient presented with foreign body sensation and visual disturbances of the right eye. Examination revealed a white coiled structure in the cornea.. Routine blood and other investigations were within normal limits. A live adult worm was extracted and identity was confirmed by microscopy to be Loa loa. Patient was treated with diethylcarbamazine and steroid. We found this case interesting as the worm was present in the anterior chamber - an unusual site and there were no other positive findings besides the lone worm.

  18. Evaluation of Anterior Chamber Volume in Cataract Patients with Swept-Source Optical Coherence Tomography.

    Science.gov (United States)

    He, Wenwen; Zhu, Xiangjia; Wolff, Don; Zhao, Zhennan; Sun, Xinghuai; Lu, Yi

    2016-01-01

    Purpose. To evaluate the anterior chamber volume in cataract patients with Swept-Source Optical Coherence Tomography (SS-OCT) and its influencing factors. Methods. Anterior chamber volume of 92 cataract patients was evaluated with SS-OCT in this cross-sectional study. Univariate analyses and multiple linear regression were used to investigate gender, age, operated eye, posterior vitreous detachment, lens opacity grading, and axial length (AXL) related variables capable of influencing the ACV. Results. The average ACV was 139.80 ± 38.21 mm(3) (range 59.41 to 254.09 mm(3)). The average ACV was significantly larger in male patients than in female patients (P = 0.001). ACV was negatively correlated with age and LOCS III cortical (C) grading of the lens (Pearson's correlation analysis, r = -0.443, P ACV was also increased with AXL (Pearson's correlation analysis, r = 0.552, P ACV (F = 10.252  P ACV varied significantly among different subjects. Influencing factors that contribute to reduced ACV were female gender, increased age, LOCS III C grade, and shorter AXL.

  19. Ring melanoma of the anterior chamber angle as a mimicker of pigmentary glaucoma.

    Science.gov (United States)

    Stadigh, Anni; Puska, Päivi; Vesti, Eija; Ristimäki, Ari; Turunen, Joni A; Kivelä, Tero T

    A 19-year-old man noticed blurred vision in his right eye. He had an intraocular pressure of 60 versus 12 mmHg in the fellow eye. He was initially diagnosed with an atypical, advanced pigmentary glaucoma. The intraocular pressure did not respond to maximal medication, deep sclerectomy, goniopuncture, and 2 cyclophotocoagulations. Sixteen months after presentation, malignancy was first suspected, and the eye was enucleated. A ring melanoma of the anterior chamber angle was confirmed by the histopathologic examination. Normal nuclear staining for breast cancer 1 gene (BRCA1)-associated protein 1 suggested that the tumor was likely of disomy 3 type with a favorable prognosis. No local or systemic recurrence has developed within 4 years. A literature review of this rare type of minimal volume diffuse uveal melanoma identified 18 additional patients. The initial diagnosis in 18 of the 19 patients with a ring melanoma of the anterior chamber angle was unilateral glaucoma with a median intraocular pressure of 40 mmHg and an age range of 16-76 years. Liver metastasis developed in 5 of 12 patients older than 45 years. This rare subtype is estimated to account for 0.05%-0.16% of all uveal melanomas. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Repeatability and reproducibility of anterior chamber volume measurements using 3-dimensional corneal and anterior segment optical coherence tomography.

    Science.gov (United States)

    Fukuda, Shinichi; Kawana, Keisuke; Yasuno, Yoshiaki; Oshika, Tetsuro

    2011-03-01

    To evaluate the repeatability and reproducibility of anterior chamber volume (ACV) measurements using swept-source 3-dimensional corneal and anterior segment optical coherence tomography (CAS-OCT) and dual Scheimpflug imaging. Department of Ophthalmology, Institute of Clinical Medicine, University of Tsukuba, Ibaraki, Japan. Nonrandomized clinical trial. Measurements were taken in normal eyes (subject group) and in eyes with primary angle closure (PAC) (patient group). In the subject group, the entire ACV and the central 8.0 mm diameter ACV were measured using CAS-OCT and dual Scheimpflug imaging. In the patient group, the entire ACV and 8.0 mm ACV were measured using CAS-OCT. The coefficient of variation and intraclass correlation coefficient (ICC) were calculated to evaluate repeatability and reproducibility, and the correlation between the 2 devices was assessed. In the subject group, the mean 8.0 mm ACV was 110.14 mm(3) ± 12.57 (SD) using CAS-OCT and 114.51 ± 14.69 mm(3) using Scheimpflug imaging; there was a significant linear correlation (r = 0.878, P ACV on CAS-OCT was 165.15 ± 29.29 mm(3). The ICCs of the 8.0 mm and entire ACV measurements were greater than 0.94. The coefficients of repeatability and reproducibility of the 8.0 mm ACV and entire ACV measurements were less than 5%. In the patient group, the 8.0 mm and entire ACV measurements showed good reproducibility and repeatability. The CAS-OCT method allowed noninvasive measurement of the entire ACV with sufficient repeatability and reproducibility. The 8.0 mm ACV measurements with CAS-OCT and Scheimpflug imaging were comparable. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Evaluation of anterior chamber angle under dark and light conditions in angle closure glaucoma: An anterior segment OCT study.

    Science.gov (United States)

    Masoodi, Habibeh; Jafarzadehpur, Ebrahim; Esmaeili, Alireza; Abolbashari, Fereshteh; Ahmadi Hosseini, Seyed Mahdi

    2014-08-01

    To evaluate changes of nasal and temporal anterior chamber angle (ACA) in subjects with angle closure glaucoma using Spectralis AS-OCT (SAS-OCT) under dark and light conditions. Based on dark-room gonioscopy, 24 subjects with open angles and 86 with narrow angles participated in this study. The nasal and temporal angle opening distance at 500 μm anterior to the scleral spur (AOD500), nasal and temporal ACA were measured using SAS-OCT in light and dark conditions. In 2 groups, ACA and AOD500 in nasal and temporal quadrants were significantly greater in light compared to dark (all with p=0.000). The AOD500 and ACA were significantly higher in nasal than temporal in measured conditions for 2 groups except the ACA and AOD500 of normal group measured in light. The difference between nasal and temporal in dark (29.07 ± 65.71 μm for AOD500 and 5.7 ± 4.07° for ACA) was greater than light (24.86 ± 79.85 μm for AOD500 and 2.09 ± 7.21° for ACA) condition. But the difference was only significant for ACA (p=0.000). The correlation analysis showed a negative correlation between AOD500 and pupil diameter in temporal and nasal quadrants (both with p=0.000). While temporal AOD500 difference correlated with spherical equivalent, temporal and asal gonioscopy, nasal AOD correlated with IOP, temporal and nasal gonioscopy. Clinically important changes in ACA structure could be detected with SAS-OCT in nasal and temporal quadrants under different illumination intensity. The results could help in improvement of examination condition for better and more accurate assessment of individuals with angle closure glaucoma. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  2. Ocular Toxicity after High-Dose Cefuroxime Injection into the Anterior Chamber

    Directory of Open Access Journals (Sweden)

    Harun Çakmak

    2016-08-01

    Full Text Available Cephalosporins are beta-lactam antibiotics and, like penicillin derivatives, they show bacteriostatic effect by disrupting bacterial cell wall synthesis. Cefuroxime is a second generation cephalosporin and the use of intracameral cefuroxime after cataract surgery has been widely used in the endophthalmitis prophylaxis. A 78-year-old male patient was operated for cataracts in both eyes about 8 years ago. Ocular trauma has occurred in the left eye nine months ago. Vitrectomy surgery combined with intraocular lens extraction was performed and the patient was left aphakic. Secondary intraocular lens implantation was performed. In this paper, we present postoperative ocular findings in a patient who was given cefuroxime into the anterior chamber 2.5 times higher than the recommended dose (25 mg/ml after secondary intraocular lens implantation.

  3. Aqueous humour dynamics in anterior chamber under influence of cornea indentation

    Science.gov (United States)

    Zuhaila, I.; Jiann, L. Y.; Sharidan, S.; Fitt, A.

    2017-04-01

    The existing temperature different between the cornea and the pupil induces the aqueous humour (AH) to circulate in the anterior chamber (AC). The buoyancy forces produced by the temperature gradient has driven the AH to flow. Previous studies have shown that cornea indentation changes the structure of the AC. This imply that the cornea indentation may change the fluid flow behaviour in the AC. A mathematical model of AH flow has been developed in order to analyse the fluid mechanics concerning the indentation of the cornea. Naiver-Stokes equations is used to describe the flow of AH in the AC. The governing equations have been solved numerically using finite element method. The results show that the cornea indentation has slow down the circulation the AH in the AC.

  4. Repeatability, reproducibility, agreement characteristics of 2 SD-OCT devices for anterior chamber angle measurements.

    Science.gov (United States)

    Akil, Handan; Dastiridou, Anna; Marion, Kenneth; Francis, Brian; Chopra, Vikas

    2017-04-01

    To evaluate the agreement, reproducibility, and repeatability of 2 spectral domain optical coherence tomography (SD-OCT) devices in Schwalbe's line (SL)-based anterior chamber angle parameters. The inferior anterior chamber angle of 65 eyes from 65 participants (33 right eyes and 32 left eyes) were scanned twice with the Nidek RS 3000 Advanced SD-OCT and Cirrus SD-OCT. SL angle opening distance (SL-AOD) and SL trabecular-iris-space area (SL-TISA) were graded by masked certified graders at the Doheny Image Reading Center. The mean SL-AOD/SL-TISA was 617.3 ± 237.9 µm/0.211 ± 0.086 mm 2 for the Cirrus and 633.7 ± 219.3 µm/0.218 ± 0.080 mm 2 for the Nidek RS 3000 Advanced SD-OCT. The repeatability (intraclass correlation coefficients [ICCs] >0.936) and intergrader reproducibility (ICCs >0.915) in SL-AOD and SL-TISA with Cirrus OCT were excellent. The repeatability (ICCs >0.948) and intergrader reproducibility (ICCs >0.709) in SL-AOD and SL-TISA with the Nidek RS 3000 Advanced SD-OCT were moderate to good. Moderate agreement between the 2 devices was also documented with a mean difference of -15.3 (limits of agreement [LoA] -246.5 to 277.1) mm for SL-AOD and 0.006 (LoA -0.096 to 0.108) mm in SL-TISA. Both devices were able to provide consistent angle measurements, but repeatability and reproducibility were better in Cirrus SD-OCT than in Nidek RS 3000 Advanced SD-OCT. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  5. Clinical outcomes of Ahmed glaucoma valve in anterior chamber versus ciliary sulcus.

    Science.gov (United States)

    Bayer, A; Önol, M

    2017-04-01

    PurposeTo evaluate the outcomes of Ahmed glaucoma valve (AGV) tube insertion through the anterior chamber angle (ACA) or through the ciliary sulcus (CS).Patients and methodsIn this case-control study, we retrospectively reviewed the charts of consecutive glaucoma patients who had undergone AGV implantation either through the ACA or the CS between March 2009 and December 2014. The main outcome measures were intraocular pressure (IOP), number of glaucoma medications prescribed, best corrected visual acuity (BCVA), glaucoma type, success rate, complications, and survival ratios. Statistical analysis was carried out using SPSS.ResultsThere were 68 eyes in the ACA group and 35 eyes in the CS group. There were no significant differences between the groups for age, sex, laterality, IOP, preoperative glaucoma medication number, BCVA or glaucoma type (P>0.05). The postoperative follow-up period was 27.2±16.5 months and 30.2±17.7 months for the ACA and the CS groups (P=0.28); IOP values were significantly reduced at the last visit to 16.4±7.2 mm Hg and 14.4±6.8 mm Hg. The difference in the last-visit IOP between the groups was not significant (P=0.06), but the IOP reduction ratio was higher in the CS group (P=0.03). There was no significant difference in the number of postoperative medications (P=0.18). Postoperative complications were similar, but the incidence of flat anterior chamber was higher in the ACA group (P=0.05).ConclusionsThe use of an AGV can control IOP in the majority of cases whether placed in the ACA or the CS. The IOP reduction ratio seemed to be higher in the CS group.

  6. Fluid mechanics of the human eye: aqueous humour flow in the anterior chamber.

    Science.gov (United States)

    Fitt, A D; Gonzalez, G

    2006-01-01

    We consider and compare the various different kinds of flow that may take place in the anterior chamber of a human eye. The physical mechanisms responsible for causing such flows may be classified as follows: (i) buoyancy-driven flow arising from the temperature difference between the anterior surface of the cornea and the iris, (ii) flow generated by the aqueous production of the ciliary body, (iii) flow generated by the interaction between buoyancy and gravity while sleeping while sleeping in a face-up position, (iv) flow generated by phakodenesis (lens tremor), (v) flow generated by Rapid Eye Movement (REM) during sleep. Each flow is studied using a traditional fluid mechanics/asymptotic analysis approach. We also assess the veracity of a hypothesis that was recently advanced [see Maurice, D.M., 1998. The Von Sallman Lecture 1996: An ophthalmological explanation of REM sleep. Exp. Eye. Res. 66, 139-145, for details] to suggest that, contrary to previous opinion, the purpose of REM during sleep is to ensure corneal respiration in the absence of the buoyant mixing that routinely takes place due to (i) above during waking conditions.

  7. [Contribution of confocal microscopy and anterior chamber OCT to the study of corneal endothelial pathologies].

    Science.gov (United States)

    Fayol, N; Labbé, A; Dupont-Monod, S; Dupas, B; Baudouin, C

    2007-04-01

    To describe the appearance of various endothelial diseases with in vivo confocal microscopy and anterior chamber optical coherence tomography (AC OCT). In this study, ten patients with five different corneal endothelial pathologies were evaluated. Three patients had cornea guttata, three had corneal endothelial precipitates, two had irido-corneo-endothelial (ICE) syndrome, one had endothelial folds, and one had breaks in the Descemet membrane. All patients had bilateral ophthalmologic examinations, in vivo confocal microscopy, and AC OCT analysis. In cases of cornea guttata, AC OCT showed a finely embossed line corresponding to the empty intercellular cavities found with in vivo confocal microscopy. Corneal endothelium precipitates had the aspect of round formations suspended with the endothelium. Iris atrophy and irido-corneal synechiae resulting from ICE syndrome were precisely visualized with the AC OCT. High-resolution images of the anterior segment could be obtained using the AC OCT. Associated with in vivo confocal microscopy, these two new imaging techniques provide a precise evaluation of endothelial pathologies.

  8. Effect of altered eating habits and periods during Ramadan fasting on intraocular pressure, tear secretion, corneal and anterior chamber parameters

    NARCIS (Netherlands)

    Kerimoglu, H.; Ozturk, B.; Gunduz, K.; Bozkurt, B.; Kamis, U.; Okka, M.

    Purpose To determine whether altered eating habits and periods, especially the pre-dawn meal, during Ramadan fasting have any significant effect on intraocular pressure (IOP), tear secretion, corneal and anterior chamber parameters. Methods IOP, basal tear secretion (BTS), reflex tear secretion

  9. Anterior Chamber-Associated Immune Deviation (ACAID: An Acute Response to Ocular Insult Protects from Future Immune-Mediated Damage?

    Directory of Open Access Journals (Sweden)

    Robert E. Cone

    2009-01-01

    Full Text Available The “immune privilege” that inhibits immune defense mechanisms that could lead to damage to sensitive ocular tissue is based on the expression of immunosuppressive factors on ocular tissue and in ocular fluids. In addition to this environmental protection, the injection of antigen into the anterior chamber or infection in the anterior chamber induces a systemic suppression of potentially damaging cell-mediated and humoral responses to the antigen. Here we discuss evidence that suggests that Anterior Chamber-Associated Immune Deviation (ACAID a is initiated by an ocular response to moderate inflammation that leads to a systemic immunoregulatory response. Injection into the anterior chamber induces a rise in TNF-α and MCP-1 in aqueous humor and an infiltration of circulating F4/80 + monocytes that home to the iris. The induction of ACAID is dependent on this infiltration of circulating monocytes that eventually emigrate to the thymus and spleen where they induce regulatory T cells that inhibit the inductive or effector phases of a cell-mediated immune response. ACAID therefore protects the eye from the collateral damage of an immune response to infection by suppressing a future potentially damaging response to infection.

  10. Predicting combined sewer overflows chamber depth using artificial neural networks with rainfall radar data.

    Science.gov (United States)

    Mounce, S R; Shepherd, W; Sailor, G; Shucksmith, J; Saul, A J

    2014-01-01

    Combined sewer overflows (CSOs) represent a common feature in combined urban drainage systems and are used to discharge excess water to the environment during heavy storms. To better understand the performance of CSOs, the UK water industry has installed a large number of monitoring systems that provide data for these assets. This paper presents research into the prediction of the hydraulic performance of CSOs using artificial neural networks (ANN) as an alternative to hydraulic models. Previous work has explored using an ANN model for the prediction of chamber depth using time series for depth and rain gauge data. Rainfall intensity data that can be provided by rainfall radar devices can be used to improve on this approach. Results are presented using real data from a CSO for a catchment in the North of England, UK. An ANN model trained with the pseudo-inverse rule was shown to be capable of predicting CSO depth with less than 5% error for predictions more than 1 hour ahead for unseen data. Such predictive approaches are important to the future management of combined sewer systems.

  11. Blunt needle revision with viscoelastic materials via the anterior chamber for early failed filtering blebs after trabeculectomy

    Directory of Open Access Journals (Sweden)

    Yamagami H

    2012-06-01

    Full Text Available Nozomi Kinoshita, Ayumi Ota, Fumihiko Toyoda, Hiroko Yamagami, Akihiro KakehashiDepartment of Ophthalmology, Saitama Medical Center, Jichi Medical University, Saitama, JapanPurpose: To report a new technique of blunt needle revision with viscoelastic materials via the anterior chamber for the treatment of early failed filtering blebs and elevated intraocular pressure after trabeculectomy, in which digital ocular massage and laser suture lysis have been ineffective.Methods: A 27-gauge blunt needle attached to a syringe containing viscoelastic material was inserted into the anterior chamber from the inferior paracentesis. The needle tip was inserted into the subscleral flap space from the filtering fistula at the anterior chamber side, and the scleral flap was lifted bluntly. The needle tip was then inserted into the subconjunctival space where the viscoelastic agent was injected and the adhesion between the sclera and conjunctiva was separated bluntly. Blunt needle revision via the anterior chamber was performed 14 times in six eyes of six patients at Saitama Medical Center, Jichi Medical University from January 2007 to May 2009. All procedures were performed within 1 month after trabeculectomy.Results: The intraocular pressure remained 21 mmHg or lower for more than 6 months in three of six eyes. Slight bleeding from the iris occurred in one of the 14 procedures, and hypotony (intraocular pressure below 5 mmHg occurred in one of the 14 procedures. No serious complications developed.Conclusion: Blunt needle revision via the anterior chamber for early failed filtering blebs is a new, simple, and safe procedure.Keywords: glaucoma, trabeculectomy, filtering bleb, needle revision, blunt needle

  12. Differences in Baseline Dark and the Dark-to-Light Changes in Anterior Chamber Angle Parameters in Whites and Ethnic Chinese

    OpenAIRE

    Wang, Dandan; Chiu, Cynthia; He, Mingguang; Wu, Lingling; Kao, Andrew; Lin, Shan

    2011-01-01

    When measured by anterior segment optical coherence tomography, the anterior chamber angle in the Chinese tends to be narrower in the dark, but the dark-to-light change is greater than in whites, independent of refractive status and anterior segment ocular dimensions.

  13. Moorfields technique of donor cornea mounting for femtosecond-assisted keratoplasty: use of viscoelastic in the artificial anterior chamber.

    Science.gov (United States)

    Iovieno, Alfonso; Chowdhury, Vivek; Stevens, Julian D; Maurino, Vincenzo

    2012-07-01

    Appropriate mounting and cutting of the donor sclero-corneal cap is often cumbersome during femtosecond laser-assisted keratoplasty. The authors describe a technique for donor cornea femtosecond laser cutting using ophthalmic viscoelastic devices. The donor sclero-corneal cap is mounted on the artificial anterior chamber using a dispersive ophthalmic viscoelastic device instead of saline solution. The chances of artificial anterior chamber pressure loss, inadequate applanation, and fluid leaks are consistently reduced with the use of dispersive ophthalmic viscoelastic devices. The speed of donor femtosecond laser cutting is increased. The viscosity and elasticity of dispersive ophthalmic viscoelastic devices greatly assist the procedure with regard to ease of applanation, corneal endothelium protection, and decreased distortion of the applanated cornea. Copyright 2012, SLACK Incorporated.

  14. Comparison of the Results of Secondary Anterior Chamber and Secondary Scleral-Fixated Intraocular Lens Implantation in Complicated Phacoemulsification Cases

    Directory of Open Access Journals (Sweden)

    Nimet Yeşim Erçalık

    2014-03-01

    Full Text Available Objectives: To compare the visual prognosis and postoperative complication rates of secondary anterior chamber (AC IOL and scleralfixated (SF intraocular lenses (IOL after complicated phacoemulsification surgery. Materials and Methods: Thirty eyes of thirty patients were reviewed for this retrospective study. The patients with secondary AC IOL implantation formed group 1 (n=15, and the patients with secondary SF IOL implantation formed group 2 (n=15. Best-corrected visual acuity (BCVA with Snellen chart, biomicroscopic examination, intraocular pressure (IOP measurement with applanation tonometer, gonioscopy performed by Goldmann’s 3-mirror contact lens, and fundus examination were performed preoperatively in all patients. Results: There was no statistically significant difference in postoperative BCVA (p=0.492 and postoperative success (BCVA not changed or better postoperatively between the 2 groups (p=0.598. Postoperative success rate was 80% in group 1 and 93.7% in Group 2. The postoperative cylindrical power of the eyes did not differ significantly between the groups (p=0.220. The postoperative complications in group 1 were as follows: transient corneal edema in 5 eyes, transient IOP elevation in 2 eyes, postoperative fibrinous reaction in the anterior chamber in one eye, late-onset secondary glaucoma in one eye, hyphema in one eye, cystoid macular edema in one eye, vitreous prolapse into the anterior chamber in one eye, and IOL malposition in one eye. The postoperative complications in group 2 were as follows: transient corneal edema in 3 eyes, vitreous prolapse into the anterior chamber in 2 eyes, IOL malposition in 2 eyes, transient IOP elevation in one eye, and retinal detachment in one eye. Conclusion: In this study, both IOL types were observed to be preferable in cases without adequate capsular support following complicated cataract surgery. However, further studies with large numbers of patients are needed to define the best choice

  15. Anterior chamber gas bubbles during femtosecond laser flap creation in LASIK: video evidence of entry via trabecular meshwork.

    Science.gov (United States)

    Soong, H Kaz; de Melo Franco, Rafael

    2012-12-01

    Femtosecond laser photodisruption of corneal stroma during laser in situ keratomileusis flap creation is accompanied by the formation of cavitation gas bubbles consisting of carbon dioxide and water vapor. Entry of these bubbles into the anterior chamber is an infrequent complication. We present video evidence that these bubbles enter via the trabecular meshwork. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Anterior chamber paracentesis and pH values in patients with acute primary angle closure.

    Science.gov (United States)

    Lu, Da-Wen; Tai, Ming-Cheng; Chang, Yun-Hsiang; Liang, Chang-Min; Chen, Ching-Long; Chien, Ke-Hung; Chen, Jiann-Torng; Chen, Yi-Hao

    2013-04-01

    To assess the efficacy and safety of anterior chamber paracentesis (ACP) and the changes in pH values in eyes with acute primary angle closure (APAC). This retrospective case-control study involved 22 patients with APAC who underwent ACP (study group) and 21 patients with APAC who did not undergo ACP (control group). Intraocular pressure (IOP) and visual acuity were measured before treatment and 15 min and 24 h after treatment in both groups. The pH of aqueous humor was measured immediately after ACP in the study group. A total of 43 eyes in 43 patients were reviewed. The IOP 15 min after ACP (23.3 ± 9.6 mmHg) and 24 h after ACP (21.6 ± 12.0 mmHg) were significantly lower than that before ACP (58.6 ± 12.9 mmHg). The IOP 15 min after ACP was significantly lower than the IOP 15 min after conventional treatment (55.4 ± 10.3 mmHg). Visual acuity recovery was achieved earlier after ACP than after conventional treatment. Hyphema after ACP was noted in one eye. The mean pH of the aqueous humor in APAC was 6.99 ± 0.35. The pH of the aqueous humor significantly correlated with the duration of acute IOP elevation and the IOP before ACP. ACP is an effective and safe procedure. The pH of aqueous humor is lower in eyes with APAC of longer duration and in eyes with higher IOP at presentation.

  17. Depth dose distribution in the water for clinical applicators of 90Sr + 90Y, with a extrapolation mini chamber

    International Nuclear Information System (INIS)

    Antonio, Patricia de Lara; Caldas, Linda V.E.; Oliveira, Mercia L.

    2009-01-01

    This work determines the depth dose in the water for clinical applicators of 90 Sr + 90 Y, using a extrapolation mini chamber developed at the IPEN, Sao Paulo, Brazil, and different thickness acrylic plates. The obtained results were compared with the international recommendations and were considered satisfactory

  18. Realize multiple hermetic chamber pressures for system-on-chip process by using the capping wafer with diverse cavity depths

    Science.gov (United States)

    Cheng, Shyh-Wei; Weng, Jui-Chun; Liang, Kai-Chih; Sun, Yi-Chiang; Fang, Weileun

    2018-04-01

    Many mechanical and thermal characteristics, for example the air damping, of suspended micromachined structures are sensitive to the ambient pressure. Thus, micromachined devices such as the gyroscope and accelerometer have different ambient pressure requirements. Commercially available process platforms could be used to fabricate and integrate devices of various functions to reduce the chip size. However, it remains a challenge to offer different ambient pressures for micromachined devices after sealing them by wafer level capping (WLC). This study exploits the outgassing characteristics of the CMOS chip to fabricate chambers of various pressures after the WLC of the Si-above-CMOS (TSMC 0.18 µm 1P5M CMOS process) MEMS process platform. The pressure of the sealed chamber can be modulated by the chamber volume after the outgassing. In other words, the pressure of hermetic sealed chambers can be easily and properly defined by the etching depth of the cavity on an Si capping wafer. In applications, devices sealed with different cavity depths are implemented using the Si-above-CMOS (TSMC 0.18 µm 1P5M CMOS process) MEMS process platform to demonstrate the present approach. Measurements show the feasibility of this simple chamber pressure modulation approach on eight-inch wafers.

  19. The clinical outcomes of surgical management of anterior chamber migration of a dexamethasone implant (Ozurdex®).

    Science.gov (United States)

    Kang, Hyunseung; Lee, Min Woo; Byeon, Suk Ho; Koh, Hyoung Jun; Lee, Sung Chul; Kim, Min

    2017-09-01

    Our purpose was to describe the clinical course, and individualized management approaches, of patients with migration of a dexamethasone implant into the anterior chamber. This was a retrospective review of four patients with seven episodes of anterior chamber migration of a dexamethasone implant. After 924 intravitreal dexamethasone injections, anterior migration of the implant occurred in four eyes of four patients (0.43%). All four eyes were pseudophakic: one eye had a posterior chamber intraocular lens in the capsular bag but in a post-laser posterior capsulotomy state, two eyes had a sulcus intraocular lens (IOL), and one eye had an iris-fixated retropupillary IOL. All eyes had a prior vitrectomy and no lens capsule. The time interval from injection to detection of the implant migration ranged from 2 to 6 weeks. Of the four eyes with corneal edema, only one eye required a corneal transplantation, although it was unclear whether the implant migration was the direct cause of the corneal decompensation because the patient had a history of bullous keratopathy resulting from an extended history of uveitis. All patients underwent surgical intervention: two patients with a repositioning procedure, and the other two patients with removal due to repeated episodes, although surgical removal was not always necessary to reverse the corneal complications. In our study, not all patients required surgical removal of the implants. Repositioning the implant back into the vitreous cavity may be considered as an option in cases involving the first episode with no significant corneal endothelial decompensation. Considering potential anterior segment complications and the loss of drug effectiveness together, an individualized approach is recommended to obtain the best treatment outcomes and to minimize the risk of corneal complications.

  20. Light-dark changes in iris thickness and anterior chamber angle width in eyes with occludable angles.

    Science.gov (United States)

    Hirose, Fumitaka; Hata, Masayuki; Ito, Shin-ichiro; Matsuki, Takaaki; Kurimoto, Yasuo

    2013-10-01

    The purpose of this study was to investigate and measure light-dark changes in iris thickness (IT) and anterior chamber angle width in eyes with occludable angles and open angles by using anterior segment optical coherence tomography (AS-OCT). We examined 153 eyes of 153 Japanese patients with primary angle closure suspect, primary angle closure, primary angle closure glaucoma, or primary open angle glaucoma. AS-OCT was used to determine pupil diameter, IT, angle opening distance at 500 μm (AOD₅₀₀), and trabecular-iris space area at 500 μm (TISA₅₀₀) in each quadrant of the anterior chamber angle (superior, inferior, temporal, and nasal) under light and dark conditions. In the angle closure cases, IT, AOD₅₀₀ and TISA₅₀₀ in the dark varied significantly among the four quadrants (P dark did not differ significantly among the four quadrants. In the angle closure cases and the open angle cases, significant negative associations were found between IT difference [IT(light)-IT(dark)] and AOD₅₀₀ difference [AOD₅₀₀(light)-AOD₅₀₀(dark)] (R = -0.411, P dark)] (R = -0.475, P dark conditions is related to the mechanism of primary angle closure. It is important to analyze both the angle structure and peripheral IT in each quadrant.

  1. Biometry of anterior segment of human eye on both horizontal and vertical meridians during accommodation imaged with extended scan depth optical coherence tomography.

    Directory of Open Access Journals (Sweden)

    Lin Leng

    Full Text Available To determine the biometry of anterior segment dimensions of the human eye on both horizontal and vertical meridians with extended scan depth optical coherence tomography (OCT during accommodation.Twenty pre-presbyopic volunteers, aged between 24 and 30, were recruited. The ocular anterior segment of each subject was imaged using an extended scan depth OCT under non- and 3.0 diopters (D of accommodative demands on both horizontal and vertical meridians. All the images were analyzed to yield the following parameters: pupil diameter (PD, anterior chamber depth (ACD, anterior and posterior surface curvatures of the crystalline lens (ASC and PSC and the lens thickness (LT. Two consecutive measurements were performed to assess the repeatability and reproducibility of this OCT. They were evaluated by calculating the within-subject standard deviation (SD, a paired t-test, intra-class correlation coefficients (ICC and the coefficient of repeatability/reproducibility (CoR.There were no significant differences between two consecutive measurements on either horizontal or vertical meridians under both two different accommodative statuses (P>0.05. The ICC for all parameters ranged from 0.775 to 0.998, except for the PSC (0.550 on the horizontal meridian under the non-accommodative status. In addition, the CoR for most of the parameters were excellent (0.004% to 4.89%. In all the parameters, only PD and PSC were found different between the horizontal and vertical meridians under both accommodative statuses (P<0.05. PD, ACD, ASC and PSC under accommodative status were significantly smaller than those under the non-accommodative status, except that the PSC at the vertical meridian did not change. In addition, LT was significantly increased when accommodation.The extended scan depth OCT successfully measured the dimensions of the anterior eye during accommodation with good repeatability and reproducibility on both horizontal and vertical meridians. The asymmetry

  2. Accuracy Evaluation of The Depth of Six Kinds of Sperm Counting Chambers for both Manual and Computer-Aided Semen Analyses

    Directory of Open Access Journals (Sweden)

    Jin-Chun Lu

    2016-12-01

    Full Text Available Background: Although the depth of the counting chamber is an important factor influencing sperm counting, no research has yet been reported on the measurement and comparison of the depth of the chamber. We measured the exact depths of six kinds of sperm counting chambers and evaluated their accuracy. Materials and Methods: In this prospective study, the depths of six kinds of sperm counting chambers for both manual and computer-aided semen analyses, including Makler (n=24, Macro (n=32, Geoffrey (n=34, GoldCyto (n=20, Leja (n=20 and Cell-VU (n=20, were measured with the Filmetrics F20 Spectral Reflectance Thin-Film Measurement System, then the mean depth, the range and the coefficient of variation (CV of each chamber, and the mean depth, relative deviation and acceptability of each kind of chamber were calculated by the closeness to the nominal value. Among the 24 Makler chambers, 5 were new and 19 were used, and the other five kinds were all new chambers. Results: The depths (mean ± SD, μm of Makler (new, Macro and Geoffrey chambers were 11.07 ± 0.41, 10.19 ± 0.48 and 10.00 ± 0.28, respectively, while those of GoldCyto, Leja and Cell-VU chambers were 23.76 ± 2.15, 20.49 ± 0.22 and 24.22 ± 2.58, respectively. The acceptability of Geoffrey chambers was the highest (94.12%, followed by Macro (65.63%, Leja (35% and Makler (20%, while that of the other two kinds and the used Makler chamber was zero. Conclusion: There existed some difference between the actual depth and the corresponding nominal value for sperm counting chambers, and the overall acceptability was very low. Moreover, the abrasion caused by the long use, as of Makler chamber, for example, may result in unacceptability of the chamber. In order to ensure the accuracy and repeatability of sperm concentration results, the depth of the sperm counting chamber must be checked regularly.

  3. Effect of altered eating habits and periods during Ramadan fasting on intraocular pressure, tear secretion, corneal and anterior chamber parameters.

    Science.gov (United States)

    Kerimoglu, H; Ozturk, B; Gunduz, K; Bozkurt, B; Kamis, U; Okka, M

    2010-01-01

    To determine whether altered eating habits and periods, especially the pre-dawn meal, during Ramadan fasting have any significant effect on intraocular pressure (IOP), tear secretion, corneal and anterior chamber parameters. IOP, basal tear secretion (BTS), reflex tear secretion (RTS), and Pentacam measurements of 31 healthy volunteers were performed at 0800 and 1600 hours during Ramadan fasting and 1 month later during non-fasting period. Comparison of measurements between fasting and non-fasting periods at 0800 hours revealed significantly higher values for IOP (P=0.005), RTS (P=0.006), and BTS (P=0.014) during fasting. Conversely at 1600 hours, IOP was significantly lower during fasting (P=0.013) and no statistically significant difference was noted for RTS and BTS. IOP showed a diurnal variation of 2.45 mmHg (P<0.001) and BTS showed a 3.06 mm decrease (P=0.04) during the fasting period. No significant differences could be found in the corneal and anterior chamber parameters during fasting and non-fasting periods. Our results revealed that fluid loading at the pre-dawn meal during Ramadan fasting might increase the IOP and tear secretion in the early morning period and these values decrease remarkably at the end of 12 h of fasting due to dehydration.

  4. Ultrasound biomicroscopy dark room provocative testing: a quantitative method for estimating anterior chamber angle width.

    Science.gov (United States)

    Ishikawa, H; Esaki, K; Liebmann, J M; Uji, Y; Ritch, R

    1999-01-01

    To describe a quantitative method for measuring the iridocorneal angle recess area, and, using this, to evaluate factors associated with appositional angle-closure during dark room provocative testing using ultrasound biomicroscopy (UBM). All patients (178 patients, 178 eyes) with clinically narrow angles referred for UBM dark room provocative testing between September 1996 and March 1998 were enrolled in this study. Images of the inferior quadrant of the angle taken under standardized dark and light conditions were analyzed. The angle recess area (ARA) was defined as the triangular area demarcated by the anterior iris surface, corneal endothelium, and a line perpendicular to the corneal endothelium drawn from a point 750 microm anterior to the scleral spur to the iris surface. ARA, and acceleration and gamma-intercept of the linear regression analysis of the ARA were calculated. In the linear regression formula, y = ax + b, the acceleration a describes the rate at which the angle widens from the scleral spur; the y-intercept b describes the distance from the scleral spur to the iris. Under dark conditions, the angles in 99 patients (55.6%) showed evidence of appositional angle-closure during testing. ARA (0.11 +/- 0.04 vs. 0.15 +/- 0.05 mm2, P dark conditions (P = .1, paired t-test), while acceleration a did (P dark conditions (P < .0001). CONCLUSIONS The ARA linear regression formula provides useful quantitative information about angle recess anatomy. The more posterior the iris insertion on the ciliary face, the less likely the provocative test will be positive.

  5. The Injection of Air/Oxygen Bubble into the Anterior Chamber of Rabbits as a Treatment for Hyphema in Patients with Sickle Cell Disease

    Directory of Open Access Journals (Sweden)

    Emre Ayintap

    2014-01-01

    Full Text Available Purpose. To investigate the changes of partial oxygen pressure (PaO2 in aqueous humour after injecting air or oxygen bubble into the anterior chamber in sickle cell hyphema. Methods. Blood samples were taken from the same patient with sickle cell disease. Thirty-two rabbits were divided into 4 groups. In group 1 (n=8, there was no injection. Only blood injection constituted group 2 (n=8, both blood and air bubble injection constituted group 3 (n=8, and both blood and oxygen bubble injection constituted group 4 (n=8. Results. The PaO2 in the aqueous humour after 10 hours from the injections was 78.45 ± 9.9 mmHg (Mean ± SD for group 1, 73.97 ± 8.86 mmHg for group 2, 123.35 ± 13.6 mmHg for group 3, and 306.47 ± 16.5 mmHg for group 4. There was statistically significant difference between group 1 and group 2, when compared with group 3 and group 4. Conclusions. PaO2 in aqueous humour was increased after injecting air or oxygen bubble into the anterior chamber. We offer to leave an air bubble in the anterior chamber of patients with sickle cell hemoglobinopathies and hyphema undergoing an anterior chamber washout.

  6. Splenic CD8(+) T cells secrete TGF-beta 1 to exert suppression in mice with anterior chamber-associated immune deviation

    NARCIS (Netherlands)

    Jiang, L.Q.; He, H.; Yang, P.Z.; Lin, X.M.; Zhou, H.Y.; Huang, X.K.; Kijlstra, A.

    2009-01-01

    Background CD8(+) regulatory T cells (Treg) have been considered to be involved in a model of ocular-induced tolerance, known as anterior chamber-associated immune deviation (ACAID). The mechanisms of suppression by CD8(+) T cells in ACAID remain only poorly understood. TGF-beta 1 is considered as

  7. Development of a multi-layer ion chamber for measurement of depth dose distributions of heavy-ion therapeutic beam for individual patients

    International Nuclear Information System (INIS)

    Shimbo, Munefumi; Futami, Yasuyuki; Yusa, Ken; Matsufuji, Naruhiro; Kanai, Tatsuaki; Urakabe, Eriko; Yamashita, Haruo; Akagi, Takashi; Higashi, Akio

    2000-01-01

    In heavy-ion radiotherapy, an accelerated beam is modified to realize a desired dose distribution in patients. The set-up of the beam-modifying devices in the irradiation system is changed according to the patient, and it is important to check the depth dose distributions in the patient. In order to measure dose distributions realized by an irradiation system for heavy-ion radiotherapy, a multi-layer ionization chamber (MLIC) was developed. The MLIC consists of 64 ionization chambers, which are stacked mutually. The interval between each ionization chamber is about 4.1 mm water. There are signal and high voltage plates in the MLIC, which are used as electrodes of the ionization chambers and phantom. Depth dose distribution from 5.09 mm to 261.92 mm water can be measured in about 30 seconds using this MLIC. Thus, it is possible to check beam quality in a short amount of time. (author)

  8. Geothermometry and Geobarometry of Kepsut-Dursunbey Volcanites (NW Anatolia, Turkey): Implications for Magma Chamber Depth and Crystallization Conditions

    Science.gov (United States)

    Kamaci, O.; Altunkaynak, S.

    2012-04-01

    The Kepsut-Dursunbey volcanic field (NW Turkey) contains various products of the Neogene magmatic activity. Two distinct volcanic suites have been recognized in the study area; Kepsut volcanic suite (KVS) and the Dursunbey volcanic suite (DVS). Both KVS and DVS are Early Miocene in age and representative for the post-collisional magmatism in western Anatolia. Mainly andesites, latites, basaltic andesites and pyroclastic rocks of KVS were formed during the early stage of volcanism in the study area. Without a major interruption in the volcanism, partly contemporanously, KVS followed by felsic volcanic products of DVS. Rhyolithic domes, lavas and extensive pyroclastic units were formed during this felsic volcanic activity. Both DVS and KVS display textural and chemical evidence for interaction of mafic and silicic magmas. This is evidenced by disequilibrium textures such as existence of rounded plagioclase phenocrysts with reaction rims (regrowth), hornblend -mantled clinopyroxenes (corona texture), synneusis, sieve textured plagioclase, patchy zones and oscilatory zoning in plagioclase phenocrysts. Basic lavas of KVS also contains xenocrysts represented by biotite mantled quartz and asidic plagioclase ovoids and glomerocrysts entrained from melt zones near base of the crust. The observed disequilibrium textures in both suites are provide evidence for magma mixing or Assimilation and fractional crystallization (AFC). Calculated pressures and temperatures using the amphibole-plagioclase geothermometer and Al-in-hornblend geobarometer give values of 5.7-7.0 kbar and 927-982 °C for the KVS and 3.7-5.3 kbar and 783-787°C for the DVS, indicating crystallization in magma chambers at deep and mid crustal levels; 21 km and 12 km, respectively. A main deep magma reservoir served as a source for the intermediate to basic lavas of KVS. The existence of similar mixing-compatible (disequilibrium) textures in both KVS and DVS support the establishment and evolution of KDVF magma

  9. Width of anterior chamber angle determined by OCT, and correlation to refraction and age in a German working population: the MIPH Eye&Health Study.

    Science.gov (United States)

    Vossmerbaeumer, Urs; Schuster, Alexander K; Fischer, Joachim E

    2013-12-01

    Optical coherence tomography (OCT) of the anterior segment allows quantitative analysis of the geometry of the chamber angle. We performed bilateral spectral-domain OCT measurements in healthy, emmetropic, hyperopic, and myopic subjects to establish correlations between the width of the angle, the refraction, and intraocular pressure of the test persons. Out of 4,617 eyes (2,309 subjects), those with refractive errors of  +3 diopters were identified by objective refraction measurement (KR-8800 Kerato-Refractometer, Topcon Inc., Japan) and examined using the anterior segment mode of a spectral-domain 3D OCT-2000 (Topcon Inc., Japan). Non-contact tonometry was performed (CT-80, Topcon Inc., Japan). One hundred and eight eyes of 54 emmetropic subjects (± 0.5 dpt) served as reference group. Previous ocular surgery was exclusion criterion in all groups. Width of the chamber angle was determined using semi-automated software tools and statistical analysis of the data (Pearson correlation, ANOVA with post-hoc test and Bonferroni correction, regression analysis) was performed using SPSS software (SPSS 19.0, Chicago, IL, USA). Six hundred and sixty-eight eyes of 398 persons (292 male, 96 female) were included in the study. Mean hyperopic refraction was +4.24 (+3  to +7.75) dpt, mean myopic refraction was -5.86 (-4 to -11.75) dpt. Valid chamber angle OCT measurements could be obtained from 50 (69.4 %) hyperopic and 400 (71.4 %) myopic eyes meeting the inclusion criteria. The mean width of the chamber angle was determined as 31.8° (range: 13.5 to 45.6, SD 7.49) in the hyperopic group, 40.8° (range: 19.3 to 66.0, SD 8.1) in the myopic group, and 36.3° (range: 21.1 to 51.8, SD 6.8) in the emmetropic reference group. Correlation was highly significant (p > 0.001) between refractive error and the aperture of the chamber angle as measured from OCT. The association of the intraocular pressure and the refraction was also highly significant (p > 0.001) for the three groups

  10. Capsid Mutated Adeno-Associated Virus Delivered to the Anterior Chamber Results in Efficient Transduction of Trabecular Meshwork in Mouse and Rat.

    Directory of Open Access Journals (Sweden)

    Barbara Bogner

    Full Text Available Adeno associated virus (AAV is well known for its ability to deliver transgenes to retina and to mediate improvements in animal models and patients with inherited retinal disease. Although the field is less advanced, there is growing interest in AAV's ability to target cells of the anterior segment. The purpose of our study was to fully articulate a reliable and reproducible method for injecting the anterior chamber (AC of mice and rats and to investigate the transduction profiles of AAV2- and AAV8-based capsid mutants containing self-complementary (sc genomes in the anterior segment of the eye.AC injections were performed in C57BL/6 mice and Sprague Dawley rats. The cornea was punctured anterior of the iridocorneal angle. To seal the puncture site and to prevent reflux an air bubble was created in the AC. scAAVs expressing GFP were injected and transduction was evaluated by immunohistochemistry. Both parent serotype and capsid modifications affected expression. scAAV2- based vectors mediated efficient GFP-signal in the corneal endothelium, ciliary non-pigmented epithelium (NPE, iris and chamber angle including trabecular meshwork, with scAAV2(Y444F and scAAV2(triple being the most efficient.This is the first study to semi quantitatively evaluate transduction of anterior segment tissues following injection of capsid-mutated AAV vectors. scAAV2- based vectors transduced corneal endothelium, ciliary NPE, iris and trabecular meshwork more effectively than scAAV8-based vectors. Mutagenesis of surface-exposed tyrosine residues greatly enhanced transduction efficiency of scAAV2 in these tissues. The number of Y-F mutations was not directly proportional to transduction efficiency, however, suggesting that proteosomal avoidance alone may not be sufficient. These results are applicable to the development of targeted, gene-based strategies to investigate pathological processes of the anterior segment and may be applied toward the development of gene

  11. Molecular description of eye defects in the zebrafish Pax6b mutant, sunrise, reveals a Pax6b-dependent genetic network in the developing anterior chamber.

    Directory of Open Access Journals (Sweden)

    Masanari Takamiya

    Full Text Available The cornea is a central component of the camera eye of vertebrates and even slight corneal disturbances severely affect vision. The transcription factor PAX6 is required for normal eye development, namely the proper separation of the lens from the developing cornea and the formation of the iris and anterior chamber. Human PAX6 mutations are associated with severe ocular disorders such as aniridia, Peters anomaly and chronic limbal stem cell insufficiency. To develop the zebrafish as a model for corneal disease, we first performed transcriptome and in situ expression analysis to identify marker genes to characterise the cornea in normal and pathological conditions. We show that, at 7 days post fertilisation (dpf, the zebrafish cornea expresses the majority of marker genes (67/84 tested genes found also expressed in the cornea of juvenile and adult stages. We also characterised homozygous pax6b mutants. Mutant embryos have a thick cornea, iris hypoplasia, a shallow anterior chamber and a small lens. Ultrastructure analysis revealed a disrupted corneal endothelium. pax6b mutants show loss of corneal epithelial gene expression including regulatory genes (sox3, tfap2a, foxc1a and pitx2. In contrast, several genes (pitx2, ctnnb2, dcn and fabp7a were ectopically expressed in the malformed corneal endothelium. Lack of pax6b function leads to severe disturbance of the corneal gene regulatory programme.

  12. The Effect of Patellar Taping on Squat Depth and the Perception of Pain in People with Anterior Knee Pain

    OpenAIRE

    Clifford, Amanda M.; Harrington, Elaine

    2013-01-01

    peer-reviewed Patellar taping is a treatment adjunct commonly used in the management of anterior knee pain. The aim of this cross sectional study was to investigate the effects of medial glide patellar taping on sagittal plane lower-limb joint kinematics and knee pain during a unilateral squat in a symptomatic population complaining of anterior knee pain. Ten participants with a history of unilateral or bilateral anterior knee pain were included in the study. Subjects were required to squa...

  13. Comparison of depth-dose distributions of proton therapeutic beams calculated by means of logical detectors and ionization chamber modeled in Monte Carlo codes

    Energy Technology Data Exchange (ETDEWEB)

    Pietrzak, Robert [Department of Nuclear Physics and Its Applications, Institute of Physics, University of Silesia, Katowice (Poland); Konefał, Adam, E-mail: adam.konefal@us.edu.pl [Department of Nuclear Physics and Its Applications, Institute of Physics, University of Silesia, Katowice (Poland); Sokół, Maria; Orlef, Andrzej [Department of Medical Physics, Maria Sklodowska-Curie Memorial Cancer Center, Institute of Oncology, Gliwice (Poland)

    2016-08-01

    The success of proton therapy depends strongly on the precision of treatment planning. Dose distribution in biological tissue may be obtained from Monte Carlo simulations using various scientific codes making it possible to perform very accurate calculations. However, there are many factors affecting the accuracy of modeling. One of them is a structure of objects called bins registering a dose. In this work the influence of bin structure on the dose distributions was examined. The MCNPX code calculations of Bragg curve for the 60 MeV proton beam were done in two ways: using simple logical detectors being the volumes determined in water, and using a precise model of ionization chamber used in clinical dosimetry. The results of the simulations were verified experimentally in the water phantom with Marcus ionization chamber. The average local dose difference between the measured relative doses in the water phantom and those calculated by means of the logical detectors was 1.4% at first 25 mm, whereas in the full depth range this difference was 1.6% for the maximum uncertainty in the calculations less than 2.4% and for the maximum measuring error of 1%. In case of the relative doses calculated with the use of the ionization chamber model this average difference was somewhat greater, being 2.3% at depths up to 25 mm and 2.4% in the full range of depths for the maximum uncertainty in the calculations of 3%. In the dose calculations the ionization chamber model does not offer any additional advantages over the logical detectors. The results provided by both models are similar and in good agreement with the measurements, however, the logical detector approach is a more time-effective method. - Highlights: • Influence of the bin structure on the proton dose distributions was examined for the MC simulations. • The considered relative proton dose distributions in water correspond to the clinical application. • MC simulations performed with the logical detectors and the

  14. Measurement of depth dose factors for various 60-Co and X-ray beams using ion chambers and thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Milu, C.

    1983-06-01

    As the depth dose factors may vary with the type of 60 Co unit (or X-ray generator) several determinations in this direction were done. The depth doses (mGy/s) for 60 Co beam (SSD=80cm) for the depths 5,10,15 and 20 cm were 11.92, 8.25, 5.75 and resp. 4.10 for field size 10x10 cm and 12.70, 9.42, 6.63 and resp. 4.93 for field size 20x20 cm. In X-ray beam, the depth doses (mGy/s) for FSD=50 cm, open-end and field size 10 cm diam. were: 1.78, 0.66, 0.23 and 0.09 for 100 kV (0.143 mm HVL, in air) and depths 5, 10, 15 and resp. 20 cm; 2.61, 1.12, 0.46 and 0.19 for 135 kV and 4.13, 1.88, 0.88 and 0.40 for 180 kV. The quality of the radiation at different depths in the water phantom was determined using a tandem TLD within Cu sleeve and TLD without Cu sleeve. The values obtained ranged from 0.018 mm Cu for 100 kV to 0.170 for 180 kV at depth 5 cm. All determinations were done using an IAEA perspex water tank and Harshaw extruded LiF as detectors. An intercomparison using LiF powder capsules prepared and sent by the IAEA Dosimetry Laboratory was performed too, in order to check the consistency of thermoluminescent dosimetry systems

  15. Corneal Collagen Cross-Linking Combined with an Artiflex Iris-Fixated Anterior Chamber Phakic Intraocular Lens Implantation in a Patient with Progressive Keratoconus

    Directory of Open Access Journals (Sweden)

    Sharif Hashmani

    2017-10-01

    Full Text Available We present here the case of a 24-year-old male who experienced progressive keratoconus and vision loss which adversely affected his ability to carry out everyday tasks. This landed him in the Hashmanis Hospital for consultation. He had a preoperative best corrected visual acuity of 6/12. He underwent multiple Oculus Pentacam examinations, which showed progressive keratoconus. Corneal collagen cross-linking (CXL was performed to stabilize his cornea and, subsequently, an Artiflex anterior chamber iris-fixated phakic intraocular lens (ACIF-PIOL was implanted to alleviate his refractive errors. The patient achieved a postoperative uncorrected visual acuity of 6/12. This report shows that CXL combined with ACIF-PIOL can be safe and effective in those with progressive keratoconus.

  16. Penetration of 45Ca in rabbit cornea following the introduction of air in the anterior chamber and its paracenthesis and following experimental intraocular hypertension

    International Nuclear Information System (INIS)

    Votockova, J.; Obenberger, J.; Babicky, A.

    1977-01-01

    In one group of Chinchilla rabbits the aqueous humor was withdrawn and the anterior chamber was refilled with air; in a second group only simple paracenthesis and withdrawal were performed; in a third group of animals experimental intraocular hypertension was produced by means of a subconjunctival injection of hypertonic sodium chloride. Immediately after these operations, a solution of 45 CaCl 2 was intravenously injected, and the rabbits were sacrificed after an interval of 30 min or 120 min. The corneas were excised and the radioactivity in central parts (trephined discs of 8 mm in diameter) and in remaining peripheral parts was determined. In all groups the corneal radioactivity in operated eyes exceeded the values found in the contralateral corneas of not operated eyes, radioactivity in these eyes being equal to the radioactivity found in the corneas of not operated rabbits in the control group. Various possible explanations of the increase of corneal radioactivity in operated eyes are briefly discussed. (author)

  17. Combined pars plana lensectomy-vitrectomy with open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for subluxated lenses.

    Science.gov (United States)

    Kazemi, S; Wirostko, W J; Sinha, S; Mieler, W F; Koenig, S B; Sheth, B P

    2000-01-01

    To review our experience with combined pars plana lensectomy-vitrectomy and open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for managing subluxated crystalline lenses. Retrospective review of 36 consecutive eyes (28 patients), all of which had subluxated crystalline lenses, managed by pars plana lensectomy-vitrectomy with insertion of an open-loop flexible AC IOL. The study was performed at the Medical College of Wisconsin, Milwaukee, over an 8-year period. An average preoperative visual acuity of 20/163 (range, 20/25 to hand motions) improved to 20/36 (range, 20/20 to 4/200) with surgery after a mean follow-up of 14 months (range, 1 to 59 months) (P IOL implantation appears to be an excellent technique for managing subluxated crystalline lenses. It is associated with a significant improvement in visual acuity (P subluxated lens through a limbal wound. Additionally, use of an AC IOL offers a simplified alternative to placement of a ciliary sulcus sutured posterior chamber intraocular lens (PC IOL).

  18. Relative dosimetry with an MR-linac: Response of ion chambers, diamond, and diode detectors for off-axis, depth dose, and output factor measurements.

    Science.gov (United States)

    O'Brien, Daniel J; Dolan, James; Pencea, Stefan; Schupp, Nicholas; Sawakuchi, Gabriel O

    2018-02-01

    The purpose of this study was to acquire beam data for an MR-linac, with and without a 1.5 T magnetic field, by using a variety of commercially available detectors to assess their relative response in the magnetic field. The impact of the magnetic field on the measured dose distribution was also assessed. An MR-safe 3D scanning water phantom was used to measure output factors, depth dose curves, and off-axis profiles for various depths and for field sizes between 2 × 2 cm 2 and 22 × 22 cm 2 for an Elekta MR-linac beam with the orthogonal 1.5 T magnetic field on or off. An on-board MV portal imaging system was used to ensure that the reproducibility of the detector position, both with and without the magnetic field, was within 0.1 mm. The detectors used included ionization chambers with large, medium, and small sensitive volumes; a diamond detector; a shielded diode; and an unshielded diode. The offset of the effective point of measurement of the ionization chambers was found to be reduced by at least half for each chamber in the direction parallel with the beam. A lateral shift of similar magnitude was also introduced to the chambers' effective point of measurement toward the average direction of the Lorentz force. A similar lateral shift (but in the opposite direction) was also observed for the diamond and diode detectors. The measured lateral shift in the dose distribution was independent of depth and field size for each detector for fields between 2 × 2 cm 2 and 10 × 10 cm 2 . The shielded diode significantly misrepresented the dose distribution in the lateral direction perpendicular to the magnetic field, making it seem more symmetric. The percentage depth dose was generally found to be lower with the magnetic field than without, but this difference was reduced as field size increased. The depth of maximum dose showed little dependence on field size in the presence of the magnetic field, with values from 1.2 cm to 1.3 cm between the 2

  19. Subthalamic nucleus involvement in executive functions with increased cognitive load: a subthalamic nucleus and anterior cingulate cortex depth recording study

    Czech Academy of Sciences Publication Activity Database

    Rusnáková-Aulická, Š.; Jurák, Pavel; Chládek, Jan; Daniel, P.; Halámek, Josef; Baláž, M.; Bočková, M.; Chrastina, J.; Rektor, I.

    2014-01-01

    Roč. 121, č. 10 (2014), s. 1287-1296 ISSN 0300-9564 R&D Projects: GA ČR GAP103/11/0933 Institutional support: RVO:68081731 Keywords : ERD/S * Anterior cingulate cortex * Subthalamic nucleus * Flanker test * Executive functions Subject RIV: BD - Theory of Information Impact factor: 2.402, year: 2014

  20. Ultrasound biomicroscopy of the anterior segment.

    Science.gov (United States)

    Liebmann, J M; Ritch, R

    1996-08-01

    New imaging technologies are revolutionizing the understanding and treatment of a wide variety of ocular disorders. Confocal scanning laser ophthalmoscopy, ultrasound biomicroscopy, confocal scanning laser polarimetry, color doppler imaging of blood flow, and optical coherence tomography are providing important information regarding disease pathophysiology, diagnosis, progression, and treatment. High frequency (50 MHz), high resolution ultrasound biomicroscopy of the anterior segment was obtained in a wide variety of disorders of the anterior segment. Tissue resolution is approximately 50 microns and the penetration depth is 5 mm. Ultrasound biomicroscopy is capable of imaging the comea, iris, anterior chamber, anterior chamber angle, posterior chamber, and ciliary body with great detail. The structures surrounding the posterior chamber, previously hidden from clinical observation, can be imaged and their normal anatomic relationships assessed. The various forms of angle closure glaucoma, such as pupillary block and plateau iris configuration, can be differentiated. The concave iris found in pigment dispersion and its response to treatment can be assessed. Visualization of anterior segment anatomy in eyes with opaque media is possible. Ultrasound biomicroscopy assists in the management of eyes with disorders of the anterior segment. Future applications of this technology will yield important information regarding accommodation, normal ocular physiology and disease pathophysiology.

  1. Correction effect of phakic posterior chamber implantable contact lens implantation on high myopia

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2018-02-01

    Full Text Available AIM: To analyze the clinical efficacy of phakic posterior chamber implantable contact lens(ICLimplantation on high myopia patients. METHODS: Thirty-four patients(68 eyeswho checked and diagnosed as high myopia in our hospital from June 2014 to June 2015 were selected as the clinical research subjects, and all the patients were given phakic posterior chamber intraocular lens implantation treatment. The diopter, visual acuity recovery, central anterior chamber depth, corneal endothelial cell count, and intraocular pressure after treatment were observed. RESULTS: The equivalent spherical refraction, central anterior chamber depth, uncorrected visual acuity and best corrected visual acuity recovery at 1, 3 and 6mo, 1 and 2a after treatment were better than those before treatment, and the differences were statistically significant(PP>0.05. There were no significant differences in uncorrected visual acuity, best corrected visual acuity, equivalent spherical refraction and central anterior chamber depth at 1, 3mo and 1 and 2a after treatment(P>0.05. CONCLUSION: The application of phakic posterior chamber intraocular lens implantation for the treatment of high myopia patients can improve the equivalent spherical refraction and central anterior chamber depth, improve uncorrected visual acuity, meanwhile, it has less effect on the patient's intraocular pressure and corneal endometrial cells, the effect maintenance and safety is better which meet their expectations.

  2. Outcomes of iris-claw anterior chamber versus iris-fixated foldable intraocular lens in subluxated lens secondary to Marfan syndrome.

    Science.gov (United States)

    Hirashima, Denise E; Soriano, Eduardo S; Meirelles, Rodrigo L; Alberti, Gustave N; Nosé, Walton

    2010-08-01

    To compare the outcome of phacoemulsification using 2 different iris-fixation techniques for intraocular lens (IOL) replacement, a foldable posterior chamber IOL (PCIOL; AcrySof MA60AC, Alcon Laboratories Inc, Fort Worth, TX) and an iris-claw anterior chamber IOL (ACIOL; Artisan, Ophtec BV), for treatment of subluxated lenses in patients with Marfan syndrome (MFS). Randomized, controlled trial. A total of 31 eyes of 16 patients with subluxated lenses associated with MFS and a preoperative corrected visual acuity (CVA) IOL type. Preoperative and postoperative ophthalmologic examination, optical coherence tomography, and endothelial cell counts were performed. We recorded CVA results at 3, 6, and 12 months, complications, endothelial cell loss, and central retinal thickness. In the iris-fixated PCIOL group, CVA was significantly improved at 3 (P = 0.011; n = 16), 6 (P = 0.006; n = 16), and 12 months (P = 0.002; n = 16). In the iris-claw ACIOL group, CVA was significantly improved at 3 (P = 0.001; n=15), 6 (P = 0.001; n = 15), and 12 months (P = 0.009; n = 12). The CVA results did not differ significantly between groups. Dislocation of the IOL occurred in 3 of 16 (18.75%) eyes in the PCIOL group. Retinal detachment occurred in 3 eyes (2 in the PCIOL group and 1 in the ACIOL group) and was successfully repaired. Postoperative foveal tomograms in both groups revealed a decrease in the mean foveal thickness (MFT; IOL dislocation tended to occur more frequently in the iris-fixated PCIOL group, the difference was not significant. At 6 months postoperatively, all study patients tended to have a thinner MFT. None of the patients in either group developed cystoid macular edema. Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  3. Correlation of gingival thickness with gingival width, probing depth, and papillary fill in maxillary anterior teeth in students of a dental college in Navi Mumbai.

    Science.gov (United States)

    Singh, Jyotsna; Rathod, Varsha J; Rao, Prajakta R; Patil, Aardra A; Langade, Deepak G; Singh, Roshan K

    2016-01-01

    The gingival biotype is of utmost importance for esthetics and biologic function. Anatomical characteristic of periodontium such as gingival thickness (GT), width of keratinized gingiva, and alveolar bone morphology will determine the behavior of periodontium when subjected to physical, chemical, or bacterial insult or during therapeutic procedure. The aim of this study was to correlate the GT with gingival width (GW), probing depth (PD), and papillary fill (PF) in relation to maxillary anterior region. Undergraduate dental students and interns from a dental college in Navi Mumbai were enrolled in the study according to the inclusion criteria. Six teeth per subject were assessed; a total of 2178 maxillary anterior teeth were examined. Subjects were examined clinically for GT, width of keratinized gingiva, pocket depth, and interdental PF. The data obtained was tabulated and subjected to statistical analysis. Spearman's correlation analysis test was performed to find the correlation of GT with GW, PD, and PF. Positive correlation was found between GT and GW ( r = 0.241). No significant correlation could be found between GT and PD; and between GT and PF. The present study confirmed a positive correlation between GT and GW. A weak negative correlation was found between GT and PD.

  4. Correlation of gingival thickness with gingival width, probing depth, and papillary fill in maxillary anterior teeth in students of a dental college in Navi Mumbai

    Directory of Open Access Journals (Sweden)

    Jyotsna Singh

    2016-01-01

    Full Text Available Context: The gingival biotype is of utmost importance for esthetics and biologic function. Anatomical characteristic of periodontium such as gingival thickness (GT, width of keratinized gingiva, and alveolar bone morphology will determine the behavior of periodontium when subjected to physical, chemical, or bacterial insult or during therapeutic procedure. Aims: The aim of this study was to correlate the GT with gingival width (GW, probing depth (PD, and papillary fill (PF in relation to maxillary anterior region. Settings and Design: Undergraduate dental students and interns from a dental college in Navi Mumbai were enrolled in the study according to the inclusion criteria. Six teeth per subject were assessed; a total of 2178 maxillary anterior teeth were examined. Subjects and Methods: Subjects were examined clinically for GT, width of keratinized gingiva, pocket depth, and interdental PF. The data obtained was tabulated and subjected to statistical analysis. Statistical Analysis Used: Spearman's correlation analysis test was performed to find the correlation of GT with GW, PD, and PF. Results: Positive correlation was found between GT and GW (r = 0.241. No significant correlation could be found between GT and PD; and between GT and PF. Conclusions: The present study confirmed a positive correlation between GT and GW. A weak negative correlation was found between GT and PD.

  5. Trabeculectomy combined with deep sclerectomy and scleral flap suture tension adjustment under an anterior chamber maintainer: a new modification of trabeculectomy.

    Science.gov (United States)

    Kayikcioglu, Ozcan R; Emre, Sinan; Kaya, Ziya

    2010-06-01

    The objective of this study was to investigate the efficacy and safety of trabeculectomy combined with deep sclerectomy in patients with primary open angled glaucoma (POAG) and to compare the results with those from conventional trabeculectomy. In the study 12 eyes of 10 patients operated with trabeculectomy combined with deep sclerectomy (Group I) and 16 eyes of 16 patients operated with conventional trabeculectomy surgery (Group II) were included. In the described form of combined deep sclerectomy with the trabeculectomy technique the superficial scleral flap was sutured with 10/0 monofilament, the number and tension of sutures were adjusted according to the outflow dynamics, under the scleral flap, of balanced salt solution (BSS) provided by an anterior chamber maintainer. In groups I and II all the patients were male POAG cases with mean ages of 60.0 +/- 19.4 and 67.0 +/- 7.1 years, respectively. The mean follow-up periods were 8.3 +/- 3.5 months for group I and 16.6 +/- 7.0 months for group II. Preoperative mean IOP were 29.7 +/- 8.3 and 29.1 +/- 12.8 mmHg mmHg, and average topical antiglaucomatous medications were 2.9 +/- 0.7 and 2.7 +/- 1.1 for groups I and II, respectively. Postoperatively mean IOP measurements were reduced in groups I and II to 10.5 +/- 2.9 vs. 9.6 +/- 4.8 mmHg at 1 week, 13.7 +/- 5.6 vs. 16.0 +/- 9.8 at 1st month, 12.3 +/- 6.4 vs. 17.3 +/- 8.0 at 3rd month, 11.0 +/- 4.1 vs. 15.3 +/- 5.8 at 6th month, 10.8 +/- 1.6 vs. 16.1 +/- 4.4 at 12th month, and 11.0 +/- 1.0 vs. 16.7 +/- 5.0 at 18th month. Statistical analysis revealed that mean postoperative IOP measurements for group I were significantly lower than for group II for all measurements except the first week (P < 0.05). At 12th month, the complete (IOP <22 mmHg without medication) and qualified (IOP <22 mmHg with medication) success rates were 83.3 and 100% for group I and 63.6 and 90.9% for group II. Postoperatively at 12th month, the mean number of antiglaucoma medications had fallen to

  6. Contaminação bacteriana da câmara anterior pós-facoemulsificação com implante de lente intra-ocular de polimetilmetacrilato ou silicone Bacterial anterior chamber contamination after phacoemulsification and polymethylmethacrylate or silicone intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Ricardo Antonio Pereira

    2004-12-01

    Full Text Available OBJETIVO: Avaliar a contaminação bacteriana da câmara anterior, após facoemulsificação não complicada, com tamanhos diferentes de incisões e lentes intra-oculares. MÉTODOS: Foi realizado estudo prospectivo randomizado, de 80 olhos de 80 pacientes, submetidos à facoemulsificação sob anestesia tópica, distribuídos aleatoriamente em dois grupos iguais. No grupo A foram alocados os pacientes submetidos à cirurgia com incisão de 3,0 mm, lente intra-ocular dobrável de silicone implantadas com injetor. No grupo B os pacientes foram submetidos à cirurgia com incisão de 5,8 mm e implante de lente intra-ocular de polimetilmetacrilato de peça única, com pinça. Ao final de cada cirurgia, uma amostra do líquido da câmara anterior foi colhida e semeada em meios de cultura para bactérias. RESULTADOS: A cultura do líquido da câmara anterior foi positiva em 2,5% dos casos do grupo A e em 5,0% do grupo B. Não houve diferença estatisticamente significante entre os dois grupos (chi2 = 0, 380, p> 0,05. CONCLUSÃO: O implante de lente intra-ocular através de incisão menor, não resultou em menor contaminação da câmara anterior na cirurgia de facoemulsificação.PURPOSE: To evaluate bacterial anterior chamber contamination following uncomplicated phacoemulsification with differents sizes of incisions. METHODS: Prospective randomized study, 80 eyes, 80 patients divided into two groups, were submitted to phacoemulsification with topical anaesthesia. In group A, with 40 patients, surgery was perfomed with 3.0 mm incision and silicone intraocular lens implant with injector. In group B the surgery was done with 5.8 mm incision and polymethylmethacrylate intraocular lens implant with forceps. Anterior chamber aspirate was taken for culture upon completion of surgery in each case. RESULTS: Anterior chamber cultures were positive in 2.5% of the cases in group A, and 5.0% in group B (chi-square test = 0.380, p>0.05, frequencies of

  7. [Dynamics of riboflavin level in aqueous humour of anterior chamber of experimental animals under standard stroma saturation by ultraviolet corneal cross-linking solutions].

    Science.gov (United States)

    Bikbov, M M; Shevchuk, N E; Khalimov, A R; Bikbova, G M

    To evaluate the dynamics of riboflavin changes in the aqueous humour of the anterior chamber (AHAC) of rabbits' eyes during standard ultraviolet (UV) cross-linking with account to the area of corneal debridement. Forty two rabbits were studied sequentially. The following solutions of riboflavin were used for cornea saturation: IR - 0.1% isosmotic riboflavin, D - Dextralink (0.1% riboflavin with 20% dextran), R - 0.1% riboflavin with 1.0% hydroxypropylmethylcellulose (HPMC). Each solution was evaluated in 3 groups that differed in the diameter of corneal debridement: group 1 - Epi-Off 3 mm (IR-3, D-3, P-3), group 2 - Epi-Off 6 mm (IR-6, D-6, R-6), and group 3 - Epi-Off 9 mm (IR-9, D-9, R-9). Aqueous humour sampling (252 samples in total) was performed in 10-minute intervals within a 60 minute period. Riboflavin levels were measured by enzyme-linked immunoassay (ID-Vit microbiological test system; Immundiagnostik, Germany). Stable growth rates of riboflavin level in the AHAC (with maximum values reached at 30-40 min) were observed for solutions D and R, regardless of the variant of corneal debridement. Moreover, throughout the whole follow-up period and regardless of the area of corneal debridement, the solution D provided a relatively lower concentration of riboflavin in the AHAC as compared to the two other solutions. At 30 minutes, when the cornea was considered ready for UV irradiation, the riboflavin level in the AHAC ranged from 385±26.1 μg/l (D-9) to 665±28 μg/l (R-9). In groups IR-9, IR-6, P-6, IR-3, and P-3 riboflavin levels were found to be in the same range starting at 20 minutes. However, even a sufficient concentration of riboflavin in the cornea or AHAC cannot guarantee safe and effective UV cross-linking, since the removed epithelium limits the area of the stroma that can be saturated with riboflavin, while the area of UV exposure is 8-10 mm. Safe and efficient standard UV cross-linking may be performed only under sufficient saturation of the

  8. Application of Anterior Segment Optical Coherence Tomography in Pediatric Ophthalmology

    Directory of Open Access Journals (Sweden)

    Ricardo Salles Cauduro

    2012-01-01

    Full Text Available Purpose. Application of anterior segment optical coherence (AS-OCT in pediatric ophthalmology. Methods. Retrospective clinical study case series of 26 eyes of 19 pediatric patients throughout a 21-month period, presenting anterior segment pathologies, were submitted to AS-OCT examination (OCT Visante, 1310 nm, Zeiss, noncontact technique, no sedation requirement. Results. AS-OCT images were obtained from 19 patients (range: 2 months to 12 years. Clinical diagnosis of anterior segment abnormalities included cornea disease (n=7, congenital anterior segment conditions (n=10, ocular trauma (n=1, anterior segment surgeries (n=2, iridocorneal angle abnormalities (n=4, intermediate uveitis (n=2. The most common OCT findings were corneal hyperreflectivity and thickening (n=15, shallow anterior chamber with iris-lens diaphragm anterior displacement (n=4, atypical corneal curvature (n=4, corneal thinning (n=4, peripheral synechiae with angle closure (n=3, increased anterior chamber depth (n=2, and proximal portion of glaucoma drainage tube (n=2. Conclusion. In the present study, noncontact AS-OCT demonstrated to be a feasible technique to evaluate the anterior segment providing anatomic details and useful to clarify diagnosis in the pediatric population.

  9. Study of biological measurement parameters of anterior segment in primary acute angle-closure glaucoma

    Directory of Open Access Journals (Sweden)

    Jun-Jie Bian

    2015-02-01

    Full Text Available AIM:To investigate biological measurement parameters of anterior segment in acute angle-closure glaucoma(AACG.METHODS: Forty-six eyes of 46 patients with AACG and 52 eyes of 52 patients with shallow anterior chamber and 50 eyes of 50 normal individuals were examined. The parameters of anterior segment including chamber crowd rate(CCR, lens thickness(LT, lens position(LPand anterior chamber depth(ACDwere measured by A-ultrasound according to different ages in each group. The data were performed statistical analysis in three groups.RESULTS: In each age range group(≥50~59 years old, ≥60~69 years old, ≥70 years old, statistically significant differences in three groups(AACG, shallow anterior chamber group and the controlswere found in CCR, LT, LP, ACD(PPP>0.05between AACG and shallow anterior chamber group in each age range group.CONCLUSION: CCR can be used as the index of evaluating crowding state of anterior segment in AACG patients and the sensitivity is better than LT and LP.

  10. Dynamic analysis of iris configuration with anterior segment optical coherence tomography.

    Science.gov (United States)

    Cheung, Carol Yim-lui; Liu, Shu; Weinreb, Robert N; Liu, Jing; Li, Haitao; Leung, Dexter Yu-lung; Dorairaj, Syril; Liebmann, Jeffrey; Ritch, Robert; Lam, Dennis Shun Chiu; Leung, Christopher Kai-shun

    2010-08-01

    To evaluate dynamic changes in iris configuration and their association with anterior chamber angle width by using anterior segment optical coherence tomography (ASOCT). Forty-six normal subjects with open angles and 40 with narrow angles (Shaffer grade dark room gonioscopy) were analyzed. The dynamic ASOCT dark-light changes of iris bowing were captured with real-time video recording and nasal iris bowing, nasal anterior chamber angle, and pupil diameter were measured in serial image frames selected from the video capture. The associations between iris bowing, iris thickness, anterior chamber depth (ACD), age, anterior chamber angle, and pupillary diameter measurements were evaluated with univariate and multivariate regression analyses. The relationship between iris bowing and pupil diameter was largely linear, with three dynamic patterns observed: (1) convex-to-convex (iris remains convex in dark and light); (2) concave-to-convex (iris changes from concave to convex from light to dark); and (3) concave-to-concave (iris remains concave in dark and light). All the subjects with narrow angles had convex-to-convex anatomy, although 43% of the subjects with open angles also demonstrated this pattern. These individuals were older and had shorter axial length (both with P dark (r = 0.472, P dark. ACD and iris bowing were independently associated with anterior chamber angle width. Independent of ACD, iris bowing is an important biometric parameter that determines angle width. Investigation of iris dynamics may offer a new perspective in understanding the risk and mechanism of primary angle closure.

  11. EFFECTS OF FLUNIXIN MEGLUMINE CONJUNCTIVAL SHOT OVER THE HUMOR AQUEOUS PROTEIN OF DOGS SUBMITTED TO THE PARACENTESIS OF THE ANTERIOR CHAMBER AVALIAÇÃO DOS EFEITOS DA FLUNIXINA MEGLUMINA, POR VIA SUBCONJUNTIVAL, SOBRE A CONCENTRAÇÃO E PADRÃO PROTEICO DO HUMOR AQUOSO DE CÃES SUBMETIDOS À PARACENTESE DA CÂMARA ANTERIOR

    OpenAIRE

    Paula Diniz Galera; José Luiz Laus; Ana Maria Barros Soares; Cassio Ricardo Ribeiro; Francislette Rodrigues de Melo

    2009-01-01

    Flunixin meglumine effects, over aqueous humor proteins of eyes on dogs who were submitted to paracentesis of the anterior chamber, were evaluated. To ten adult dogs clinically healthy were given a subconjunctival shot with flunixin meglumine (1.1mg/Kg) on the right eye and sterilized saline solution 0.9% on the left eye, with the same volume. After general anesthesia, were submitted to two paracentesis of the both eyes to collect 0.2mL of first and second aqueous. The samples were...

  12. Avaliação da contaminação da câmara anterior na cirurgia de facoemulsificação com implante de lente intra-ocular Anterior chamber contamination in phacoemulsification surgery with intraocular lens implant

    Directory of Open Access Journals (Sweden)

    Cesar Nobuo Shiratori

    2002-06-01

    Full Text Available Objetivo: Avaliar a existência de contaminação da câmara anterior durante a facectomia por facoemulsificação com implante de lente intra-ocular. Método: Foi realizado estudo prospectivo, avaliando-se 30 pacientes submetidos a facectomia por facoemulsificação com implante de lente intra-ocular, colhendo-se duas amostras de humor aquoso, uma obtida no início e outra no final da cirurgia. As amostras foram semeadas em meio de cultura para germes aeróbios, anaeróbios e fungos. Resultado: Todas as amostras avaliadas resultaram negativas. Conclusão: A contaminação da câmara anterior na cirurgia de facoemulsificação com implante de lente intra-ocular, usando os cuidados necessários, é infreqüente.Purpose: To evaluate the frequency of anterior chamber contamination during phacoemulsification surgery with intraocular lens implant. Method: A prospective study was done with 30 patients submitted to phacoemulsification surgery with intraocular lens implant. Two samples of the aqueous humor were removed from the anterior chamber, one at the beginning and another one at the end of the surgery and were inoculated in culture plates for anaerobic and aerobic bacteria and fungi. Results: Intraocular aspirates yielded negative cultures. Conclusion: The absence of microorganisms in the samples evaluated allowed us to conclude that contamination during the phacoemulsification surgery with lens implant is unusual.

  13. Importância da velocidade do movimento celular na câmara anterior, na avaliação clínica das uveítes Importance of the speed of the cellular movement in the anterior chamber in the clinical evaluation of uveitis

    Directory of Open Access Journals (Sweden)

    Fernando Antônio L. Mendes Furtado

    2000-08-01

    Full Text Available Objetivo: Acrescentar ao oftalmologista mais um dado para avaliação clínica das uveítes, que acometem o segmento anterior; seja contribuindo para revelar a intensidade do processo inflamatório, seja ajudando a nortear a conduta terapêutica. Métodos: Estudamos 46 pacientes portadores de uveíte e com reação celular na câmara anterior. Observamos a velocidade do deslocamento das células no humor aquoso e a relacionamos com a intensidade do processo inflamatório, comparando com a sintomatologia e principais sinais clínicos. Resultados: Os resultados nos mostram que existe uma correlação direta entre a velocidade das células na câmara anterior e o grau de inflamação. Quanto mais grave a inflamação, menor é o deslocamento das células. E podemos aplicar esse fato na abordagem clínica das uveítes. Em algumas situações é mais fácil perceber alterações na velocidade que na quantidade de células ou flare. Conclusões: Nosso estudo apresenta um elemento novo na semiologia das uveítes, já que não encontramos referências na literatura médica. Familiarizando-se com a velocidade dos movimentos celulares na câmara anterior, podemos dispor de uma valioso recurso que nos ajude no exame do paciente com uveíte. Há casos em que a mudança na velocidade é o único elemento a nos indicar uma piora ou melhora do quadro clínico.Purpose: To add for the ophthalmologist an element for clinical evaluation of uveitis, affecting the anterior segment; contributing both to reveal the intensity of the inflammatory process and helping to guide the therapeutic management conduct. Methods: We studied 46 uveitis patients with cellular reaction in the anterior chamber. We observed the speed of the displacement of the cells in the aqueous humor and related it to the intensity of the inflammatory process, in comparison with the symptomatology and main clinical signs. Results: The results showed that there is an inverse correlation between the

  14. Topographical and depth-dependent glycosaminoglycan concentration in canine medial tibial cartilage 3 weeks after anterior cruciate ligament transection surgery—a microscopic imaging study

    Science.gov (United States)

    Mittelstaedt, Daniel; Kahn, David

    2016-01-01

    Background Medical imaging has become an invaluable tool to diagnose damage to cartilage. Depletion of glycosaminoglycans (GAG) has been shown to be one of the early signs of cartilage degradation. In order to investigate the topographical changes in GAG concentration caused by the anterior cruciate ligament transection (ACLT) surgery in a canine model, microscopic magnetic resonance imaging (µMRI) and microscopic computed tomography (µCT) were used to measure the GAG concentration with correlation from a biochemical assay, inductively coupled plasma optical emission spectroscopy (ICP-OES), to understand where the topographical and depth-dependent changes in the GAG concentration occur. Methods This study used eight knee joints from four canines, which were examined 3 weeks after ACLT surgery. From right (n=3) and left (n=1) medial tibias of the ACLT and the contralateral side, two ex vivo specimens from each of four locations (interior, central, exterior and posterior) were imaged before and after equilibration in contrast agents. The cartilage blocks imaged using µMRI were approximately 3 mm × 5 mm and were imaged before and after eight hours submersion in a gadolinium (Gd) contrast agent with an in-plane pixel resolution of 17.6 µm2 and an image slice thickness of 1 mm. The cartilage blocks imaged using µCT were approximately 2 mm × 1 mm and were imaged before and after 24 hours submersed in ioxaglate with an isotropic voxel resolution of 13.4 µm3. ICP-OES was used to quantify the bulk GAG at each topographical location. Results The pre-contrast µMRI and µCT results did not demonstrate significant differences in GAG between the ACLT and contralateral cartilage at all topographical locations. The post-contrast µMRI and µCT results demonstrated topographically similar significant differences in GAG concentrations between the ACLT and contralateral tibia. Using µMRI, the GAG concentrations (mg/mL) were measured for the ACLT and contralateral

  15. Anterior Segment Dimensions Following Laser Iridotomy in Acute Primary Angle Closure and Fellow Eyes.

    Science.gov (United States)

    Moghimi, Sasan; Bijani, Faezeh; Chen, Rebecca; Yasseri, Mehdi; He, Mingguang; Lin, Shan C; Weinreb, Robert N

    2018-02-01

    To compare the change in anterior segment morphology after laser peripheral iridotomy (LPI) in acute primary angle closure (APAC) and their fellow eyes. Prospective, fellow eye-matched case series. In this study 42 individuals with unilateral episode of APAC were enrolled and the anterior segment optical coherence tomography (ASOCT) images were obtained in both eyes at baseline and at 6 weeks after LPI. A linear mixed-effects model was used to compare changes in anterior chamber and angle variables with consideration of laterality as the random effect and pupil diameter as the fixed effect. APAC eyes had smaller angle parameters (P = .013 for all), less central anterior chamber depth (cACD) (P APAC and fellow eyes. cACD (P = .003) and ACA (P APAC eyes. However, there was no significant change in cACD (P = .190) and LV (P = .430) in fellow eyes. In both APAC eyes and fellow eyes, iris curvature decreased after LPI (P APAC eyes and their fellow eyes, LPI resulted in significant anterior chamber angle widening and increased anterior chamber area. In APAC eyes, the iris flattened, cACD deepened, and the lens shifted posteriorly after resolution of the attack. However, in fellow eyes, the increase in ACA was mainly owing to decreased iris curvature. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Identifying anterior segment crystals.

    OpenAIRE

    Hurley, I W; Brooks, A M; Reinehr, D P; Grant, G B; Gillies, W E

    1991-01-01

    A series of 22 patients with crystals in the anterior segment of the eye was examined by specular microscopy. Of 10 patients with hypermature cataract and hyperrefringent bodies in the anterior chamber cholesterol crystals were identified in four patients and in six of the 10 in whom aspirate was obtained cholesterol crystals were demonstrated in three, two of these having shown crystals on specular microscopy. In 10 patients with intracorneal crystalline deposits, cholesterol crystals were f...

  17. Refraction and eye anterior segment parameters in schizophrenic patients

    Directory of Open Access Journals (Sweden)

    Tongabay Cumurcu

    2015-06-01

    Full Text Available ABSTRACT Purpose: To evaluate the difference in terms of refractive errors and anterior segment parameters between schizophrenic patients and healthy volunteers. Methods: This study compared 70 patients (48 men who were diagnosed with schizophrenia with a control group of 60 (35 men who were similar in terms of age, gender, education, and socioeconomic level. Anterior segment examination was performed using a Scheimflug system. Axial length and lens thickness (LT were measured using optic biometry. The following tests were administered to the psychiatric patient group: Brief Psychiatric Rating Scale (BPRS, Scale for the Assessment of Negative Symptoms (SANS, and Scale for the Assessment of Positive Symptoms (SAPS. Results: Mild myopia was detected in both the schizophrenic and control groups, with no statistically significant difference (p>0.005. Corneal volume (CV, anterior chamber volume (ACV, anterior chamber depth (ACD, and central corneal thickness (CCT values were lower in the schizophrenic group, and there was a statistically significant between-group difference (p=0.026, p=0.014, p=0.048, and p=0.005, respectively. LT was greater in schizophrenics, and the difference was found to be statistically significant (p=0.006. A statistically significant negative correlation was found between SAPS and cylinder values (p=0.008. The axial eye length, cylinder value, pupil diameter, mean keratometric value, and anterior chamber angle revealed no statistically significant difference between the groups (p>0.05. Conclusion: No statistically significant difference was detected in terms of refraction disorders between schizophrenics and the healthy control group, while some differences in anterior chamber parameters were present. These results demonstrate that schizophrenics may exhibit clinical and structural differences in the eye.

  18. Test chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    1999-01-01

    A test chamber for measuring electromagnetic radiation emitted by an apparatus to be tested or for exposing an apparatus to be tested to an electromagnetic radiation field. The test chamber includes a reverberation chamber made of a conductive tent fabric. To create a statistically uniform field in

  19. Test chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2009-01-01

    A test chamber for measuring electromagnetic radiation emitted by an apparatus to be tested or for exposing an apparatus to be tested to an electromagnetic radiation field. The test chamber includes a reverberation chamber made of a conductive tent fabric. To create a statistically uniform field in

  20. Cloud Chamber

    DEFF Research Database (Denmark)

    Gfader, Verina

    Cloud Chamber takes its roots in a performance project, titled The Guests 做东, devised by Verina Gfader for the 11th Shanghai Biennale, ‘Why Not Ask Again: Arguments, Counter-arguments, and Stories’. Departing from the inclusion of the biennale audience to write a future folk tale, Cloud Chamber...

  1. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  2. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  3. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  4. Depth dose distribution in the water for clinical applicators of {sup 90}Sr + {sup 90}Y, with a extrapolation mini chamber; Distribuicao de dose em profundidade na agua para aplicadores clinicos de {sup 90}Sr + {sup 90}Y, com uma mini-camara de extrapolacao

    Energy Technology Data Exchange (ETDEWEB)

    Antonio, Patricia de Lara; Caldas, Linda V.E., E-mail: patrilan@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Oliveira, Mercia L., E-mail: mercial@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2009-07-01

    This work determines the depth dose in the water for clinical applicators of {sup 90}Sr + {sup 90}Y, using a extrapolation mini chamber developed at the IPEN, Sao Paulo, Brazil, and different thickness acrylic plates. The obtained results were compared with the international recommendations and were considered satisfactory

  5. Ionization chambers

    International Nuclear Information System (INIS)

    Boag, J.W.

    1987-01-01

    Although a variety of solid-state and chemical methods for measuring radiation dose have been developed in recent decades and calorimetry can now provide an absolute standard of reference, ionization dosimetry retains its position as the most widely used, most convenient, and, in most situations, most accurate method of measuring either exposure or absorbed dose. The ionization chamber itself is the central element in this system of dosimetry. In this chapter the principles governing the construction and operation of ionization chambers of various types are examined. Since the ionization chambers now in general use are nearly all of commercial manufacture, the emphasis is on operating characteristics and interpretation of measurements rather than on details of construction, although some knowledge of the latter is often required when applying necessary corrections to the measured quantities. Examples are given of the construction of typical chambers designed for particular purposes, and the methods of calibrating them are discussed

  6. Effects of 1% cyclopentolate hydrochloride on anterior segment parameters obtained with Pentacam in young adults

    Directory of Open Access Journals (Sweden)

    Ceyhun Arici

    2014-08-01

    Full Text Available Purpose: To investigate the effects of topically applied 1% cyclopentolate hydrochloride on anterior segment parameters obtained with a Pentacam rotating Scheimpflug camera in healthy young adults. Methods: Anterior segment analyses of 25 eyes from 25 young adults (Group 1, before and after 45 min of 1% cyclopentolate hydrochloride application, were performed. For a control group (cycloplegia-free, Group 2, 24 eyes of 24 age- and sex-matched healthy cases were evaluated twice at 45 min intervals. The results obtained from the groups were compared statistically. Results: The mean ages of the groups were 23.04 ± 3.42 (range, 18-29 and 22.4 ± 2.05 (range, 18-27 years for Groups 1 and 2, respectively (p=0.259. In Group 1, measurements between the two analyses were significantly different for the values of anterior chamber depth (ACD, anterior chamber angle (ACA, and anterior chamber volume (ACV (p<0.05, whereas no statistical difference was found for the central corneal thickness (CCT and keratometry (K1, K2 measurements. In Group 2, none of these parameters were statistically different between the two analyses. Conclusions: Topically applied 1% cyclopentolate hydrochloride caused an increase in the ACD and ACV values, and a decrease in the ACA value. However, it had no significant effect on the CCT and keratometry measurements. It is important to consider these effects when using the Pentacam device on young adults with cycloplegia and when applying it for various reasons.

  7. Evaluation of anterior segment parameters in patients with pseudoexfoliation syndrome using Scheimpflug imaging

    Directory of Open Access Journals (Sweden)

    Alime Gunes

    2016-06-01

    Full Text Available ABSTRACT Purpose: To evaluate anterior segment parameters in patients with pseudoexfoliation syndrome (PXS using Scheimpflug imaging. Methods: Forty-three PXS patients and 43 healthy control subjects were included in this cross-sectional study. All participants underwent a detailed ophthalmologic examination. Anterior segment parameters were measured using a Scheimpflug system. Results: Considering the PXS and control groups, the mean corneal thicknesses at the apex point (536 ± 31 and 560 ± 31 µm, respectively, p=0.001, at the center of the pupil (534 ± 31 and 558 ± 33 µm, respectively, p=0.001, and at the thinnest point (528 ± 30 and 546 ± 27 µm, respectively, p=0.005 were significantly thinner in PXS patients. Visual acuity was significantly lower (0.52 ± 0.37 versus 0.88 ± 0.23, p<0.001 and axial length was significantly longer (23.9 ± 0.70 mm versus 23.2 ± 0.90 mm, p=0.001 in the PXS eyes than in the control eyes. There were no statistically significant differences in the mean values of keratometry, anterior chamber angle, anterior chamber depth, corneal volume, and anterior chamber volume between the PXS and control eyes. Conclusions: The patients with PXS had thinner corneas, worse visual acuity, and longer axial length compared with those in the healthy controls.

  8. Anterior segment optical coherence tomography for the quantitative evaluation of the anterior segment following Boston keratoprosthesis.

    Directory of Open Access Journals (Sweden)

    Joann J Kang

    Full Text Available OBJECTIVE: To quantitatively evaluate the anterior segment using anterior segment optical coherence tomography (AS-OCT following Boston keratoprosthesis type 1. METHODS: A retrospective study consisted of AS-OCT imaging at a single time point postoperatively in 52 eyes. Main outcomes measures include anatomical and functional anterior chamber depth (ACD, angle (ACA and peripheral and proximal synechiae. RESULTS: The mean time point of imaging was 19.3 months postoperatively. Average anatomical and functional ACD was 2.0 and 0.21 mm respectively, and mean ACA ranged from 2.5° to 6.14° in representative meridians. An average of 8.7 clock hours of angle closure was observed in the 25 eyes in which all meridians were imaged. The majority of eyes showed peripheral (86.5% and proximal (67.3% synechiae. CONCLUSIONS: AS-OCT is a useful tool for quantitative evaluation of anterior segment and angle after keratoprosthesis, which is otherwise poorly visible. The majority of eyes showed shallow ACD, extensive angle closure and synechiae formation.

  9. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  10. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  11. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  12. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  13. Robert Chambers

    NARCIS (Netherlands)

    K. Biekart (Kees); D.R. Gasper (Des)

    2013-01-01

    textabstractProfessor Robert Chambers is a Research Associate at the Institute of Development Studies (IDS), University of Sussex (Brighton, UK), where he has been based for the last 40 years, including as Professorial Research Fellow. He became involved in the field of development management in the

  14. Suppression chamber

    International Nuclear Information System (INIS)

    Goto, Hiroshi; Tsuji, Akio.

    1976-01-01

    Purpose: To miniaturize the storage tank of condensated water in BWR reactor. Constitution: A diaphragm is provided in a suppression chamber thereby to partition the same into an inner compartment and an outer compartment. In one of said compartments there is stored clean water to be used for feeding at the time of separating the reactor and for the core spray system, and in another compartment there is stored water necessary for accomplishing the depressurization effect at the time of coolant loss accident. To the compartment in which clean water is stored there is connected a water cleaning device for constantly maintaining water in clean state. As this cleaning device an already used fuel pool cleaning device can be utilized. Further, downcomers for accomplishing the depressurization function are provided in both inner compartment and outer compartment. The capacity of the storage tank can be reduced by the capacity of clean water within the suppression chamber. (Ikeda, J.)

  15. Toxic anterior segment syndrome following deep anterior lamellar keratoplasty

    Directory of Open Access Journals (Sweden)

    Neslihan Sevimli

    Full Text Available ABSTRACT We present the case of a 31-year-old patient with toxic anterior segment syndrome (TASS that developed after undergoing deep anterior lamellar keratoplasty (DALK. She had keratoconus, and despite wearing hard contact lenses for many years in the left eye, her vision had deteriorated; therefore, DALK was performed on this eye. The preoperative visual acuity (VA was finger counting at 3 m. Routine DALK was performed using the "big-bubble" technique. The corneal entry incision was hydrated at the end of the surgery, which was terminated by air injection into the anterior chamber. On postoperative day 1, VA was at the level of hand movements, and the cornea was edematous. Topical high-dose dexamethasone and oral steroids were initiated considering the diagnosis of TASS. Subsequently, the patient's VA increased, and the corneal edema decreased. We believe that the use of re-sterilized cannulas may have been the likely cause of TASS. Although DALK can be performed without interfering with the anterior chamber, one should keep in mind that TASS may occur in response to the solution used to hydrate the incision site and the air injected into the anterior chamber.

  16. EFFECTS OF FLUNIXIN MEGLUMINE CONJUNCTIVAL SHOT OVER THE HUMOR AQUEOUS PROTEIN OF DOGS SUBMITTED TO THE PARACENTESIS OF THE ANTERIOR CHAMBER AVALIAÇÃO DOS EFEITOS DA FLUNIXINA MEGLUMINA, POR VIA SUBCONJUNTIVAL, SOBRE A CONCENTRAÇÃO E PADRÃO PROTEICO DO HUMOR AQUOSO DE CÃES SUBMETIDOS À PARACENTESE DA CÂMARA ANTERIOR

    Directory of Open Access Journals (Sweden)

    Paula Diniz Galera

    2009-12-01

    Full Text Available

    Flunixin meglumine effects, over aqueous humor proteins of eyes on dogs who were submitted to paracentesis of the anterior chamber, were evaluated. To ten adult dogs clinically healthy were given a subconjunctival shot with flunixin meglumine (1.1mg/Kg on the right eye and sterilized saline solution 0.9% on the left eye, with the same volume. After general anesthesia, were submitted to two paracentesis of the both eyes to collect 0.2mL of first and second aqueous. The samples were submitted to Bradford test, wich proteins concentrations were  15.98mg/dL ± 4.48 e 11.46mg/dL ± 2.72 for the right and the left eyes, respectively, on the first paracentesis and 119.8mg/dL ± 6.74 e 120.63mg/dL ± 22.4 for the right and the left eyes, on the second paracentesis. There was no significant statistically differences between the protein values of the treated eyes in comparison with the control one. When compared, the proteins concentrations between the first and second paracentesis of the right and left eyes, statistic differences were found between these two moments (p<0.001. SDS-PAGE showed differences in the protein patterns of aqueous humor in result of the paracentesis.

    KEY WORDS: Aqueous humor, eye, flunixin meglumine, paracentesis, proteíns.

    Avaliaram-se os efeitos da flunixina meglumina, pela via subconjuntival, sobre as proteínas do humor aquoso de olhos de cães submetidos à paracentese da câmara anterior. Dez animais adultos, clinicamente sadios, receberam, por aplicação subconjuntival, flunixina meglumina (1,1mg/kg no olho direito e solução salina estéril a 0,9% no olho esquerdo, em igual volume. Mediante anestesia geral, foram submetidos a duas paracenteses de ambos os olhos para coleta de 0,2mL de aquoso primário e secundário, respectivamente. As amostras foram submetidas ao Teste de Bradford, cujas concentrações proteicas (média e desvio-padrão obtidas foram de 15

  17. Pretreatment anterior segment imaging during acute primary angle closure: insights into angle closure mechanisms in the acute phase.

    Science.gov (United States)

    Sng, Chelvin C A; Aquino, Maria Cecilia D; Liao, Jiemin; Ang, Marcus; Zheng, Ce; Loon, Seng Chee; Chew, Paul T K

    2014-01-01

    To describe anterior segment optical coherence tomography (ASOCT) parameters during acute primary angle closure (APAC) before therapeutic interventions and comparative analyses of biometric parameters of APAC eyes with fellow eyes. Prospective, comparative case series. Thirty-one consecutive patients with APAC. All patients underwent ASOCT imaging of both eyes during the attack, before therapeutic interventions were administered. Custom software was used to measure anterior chamber depth (ACD), anterior chamber area (ACA), anterior chamber volume (ACV), iris curvature (I-Curv), iris area (I-Area), lens vault (LV), and angle opening distance (AOD750), trabecular iris space area (TISA750), and iris thickness (IT750) at 750 μm from the scleral spur. Multivariate logistic regression modeling using forward selection was used to determine the most important biometric variables associated with APAC compared with the fellow eye during the attack. Anterior segment biometric parameters associated with APAC. The mean age of the patients was 60.9±7.5 years, and 11 patients (35.5%) were male. The mean intraocular pressure was 3.8±9.2 mmHg in the APAC eye and 4.2±4.3 mmHg in the fellow eye before treatment (P APAC eyes had smaller ACD, ACA, ACV, I-Curv (all P APAC occurrence, with ACD accounting for 18.1% and I-Curv accounting for 14.1% of this variance. Shallower ACD and smaller I-Curv were the 2 main anterior segment biometric parameters associated with APAC during the attack. These findings present new insights into the anterior segment biometric parameters of APAC and fellow eyes before therapeutic interventions. Anatomic changes in the anterior segment explained only about one third of the variance in APAC occurrence, and the role of nonanatomic factors require further investigation. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  18. Anterior segment optical coherence tomography changes with introduction and discontinuation of tamsulosin.

    Science.gov (United States)

    Al-Kharashi, Abdullah; Azimzadeh, Amir A; Leung, Jerry; Radomski, Sidney; Radomski, Lenny; Lam, Wai-Ching

    2016-01-01

    The aim of this study was to quantify changes and reversibility in pupil dilation and iris dilator muscle region thickness associated with introduction and subsequent discontinuation of tamsulosin in patients naïve to this drug with the aid of an anterior OCT system. The study was carried out on 7 patients (14 eyes) naïve to tamsulosin and with benign prostatic hypertrophy (BHP). Measurements taken by Vistante OCT were done pre- and post-dilation of the following: pupil size, iris dilator muscle region (DMR) thickness, sphincter muscle region (SMR) thickness, and anterior chamber depth. These measurement were taken at Day 0 (tamsulosin naive), Day 30 (after one month of tamsulosin, the treatment period) and day 60 (after one month of no tamsulosin, the discontinuation period). Post-dilation pupil diameter significantly increased during the discontinuation period ( P  = 0.047). Iris DMR thickness measurements post-dilation significantly decreased during treatment ( P  = 0.00044), discontinuation (0.00011), and combined periods ( P  = 0.000050). Anterior chamber depth measurements in post-dilation were significantly decreased during treatment ( P  = 0.0016), discontinuation ( P  = 0.017), and combined periods ( P  = 0.00022). Tamsulosin discontinuation effectively increases dilated pupil size, a measure that has been inversely linked to IFIS incidence pre-operatively. Decreased DMR thickness in this short term likely illustrates changes aside from atrophy, such as vascular changes. Decreased anterior chamber depths suggest aqueous humor production is decreased as well.

  19. Chamber transport

    International Nuclear Information System (INIS)

    Olson, Craig L.

    2001-01-01

    Heavy ion beam transport through the containment chamber plays a crucial role in all heavy ion fusion (HIF) scenarios. Here, several parameters are used to characterize the operating space for HIF beams; transport modes are assessed in relation to evolving target/accelerator requirements; results of recent relevant experiments and simulations of HIF transport are summarized; and relevant instabilities are reviewed. All transport options still exist, including (1) vacuum ballistic transport, (2) neutralized ballistic transport, and (3) channel-like transport. Presently, the European HIF program favors vacuum ballistic transport, while the US HIF program favors neutralized ballistic transport with channel-like transport as an alternate approach. Further transport research is needed to clearly guide selection of the most attractive, integrated HIF system

  20. Anterior segment parameters: comparison of 1-piece and 3-piece acrylic foldable intraocular lenses.

    Science.gov (United States)

    Behrouz, Mahmoud Jabbarvand; Kheirkhah, Ahmad; Hashemian, Hesam; Nazari, Rahman

    2010-10-01

    To compare anterior segment parameters between 1-piece and 3-piece acrylic foldable intraocular lenses (IOLs). Farabi Eye Hospital, Tehran, Iran. Prospective randomized comparative case series. Eyes scheduled for phacoemulsification were randomized into 2 equal groups to receive a 1-piece (AcrySof SA60AT) or 3-piece (AcrySof MA60AC) foldable acrylic IOL. Scheimpflug imaging (Pentacam) was used to measure anterior segment parameters, including anterior chamber depth (ACD), anterior chamber angle (ACA), and anterior chamber volume (ACV), preoperatively and 1 week and 3 months postoperatively. The study evaluated 125 eyes (123 patients). There was a statistically significant postoperative increase in ACD, ACA, and ACV at 1 week and 3 months in both IOL groups. Although the mean ACD was significantly higher in the 3-piece group at 1 week, there was no significant between-group difference in ACD, ACA, or ACV at 3 months. There was no significant change in anterior segment parameters from 1 week to 3 months in the 1-piece group; however, the 3-piece group had statistically significant decreases in ACD, ACA, and ACV. Refraction remained stable throughout the follow-up in the 1-piece group but showed a significant myopic shift from 1 week to 3 months in the 3-piece group. After phacoemulsification, the 1-piece acrylic foldable IOL showed little axial movement and provided stable refraction throughout the follow-up. The 3-piece IOL had significant forward movement and led to a myopic shift within 3 months postoperatively. Results indicate that spectacles can be prescribed earlier in eyes with a 1-piece IOL. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Diurnal Variation of Optical Coherence Tomography Measurements of Static and Dynamic Anterior Segment Parameters.

    Science.gov (United States)

    Xu, Benjamin Y; Penteado, Rafaella C; Weinreb, Robert N

    2018-01-01

    To examine the diurnal variation of static and dynamic anterior segment parameters in young, healthy eyes by comparing anterior segment optical coherence tomography (AS-OCT) measurements obtained in the morning and evening and also in the light and dark. Twenty-two subjects ranging from 19 to 47 years of age with no past ocular history were selected. Imaging was performed with the Tomey CASIA2 AS-OCT device in 2 fixed lighting environments, light and dark, between the hours of 08:30 to 10:00 and 17:30 to 19:00. Four AS-OCT images were analyzed per eye. Pupil diameter (PD), iris area (IA), iris curvature (IC), anterior chamber depth (ACD), lens vault (LV), anterior chamber width (ACW), anterior chamber area (ACA), angle opening distance (AOD), angle recess area (ARA), trabecular iris space area (TISA), and trabecular iris angle (TIA) were measured. Pupil diameter was similar between the AM and PM groups in the light (P=0.89) and dark (P=0.51). There was no significant difference between AM and PM measurement values for any of the static or dynamic parameters in the light (P>0.39) and dark (P>0.31). Intraclass correlation coefficients (ICC) demonstrated excellent agreement between AM and PM measurement values in the light (ICC>0.81) and dark (ICC>0.93). In addition, there was no significant difference between AM and PM angle opening distance at 500 µm measurement values in the light (P>0.34) and dark (P>0.40) when each of 8 angle sectors was analyzed individually. No significant diurnal variation of static or dynamic anterior segment parameter measurements was detected in the light and dark. Diurnal variation of these parameters does not regularly occur in young, healthy eyes.

  2. Precise measurement of scleral radius using anterior eye profilometry.

    Science.gov (United States)

    Jesus, Danilo A; Kedzia, Renata; Iskander, D Robert

    2017-02-01

    To develop a new and precise methodology to measure the scleral radius based on anterior eye surface. Eye Surface Profiler (ESP, Eaglet-Eye, Netherlands) was used to acquire the anterior eye surface of 23 emmetropic subjects aged 28.1±6.6years (mean±standard deviation) ranging from 20 to 45. Scleral radius was obtained based on the approximation of the topographical scleral data to a sphere using least squares fitting and considering the axial length as a reference point. To better understand the role of scleral radius in ocular biometry, measurements of corneal radius, central corneal thickness, anterior chamber depth and white-to-white corneal diameter were acquired with IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany). The estimated scleral radius (11.2±0.3mm) was shown to be highly precise with a coefficient of variation of 0.4%. A statistically significant correlation between axial length and scleral radius (R 2 =0.957, pscleral radius. Lastly, no correlation was observed comparing scleral radius to the central corneal thickness (R 2 =0.047, p=0.161). Three-dimensional topography of anterior eye acquired with Eye Surface Profiler together with a given estimate of the axial length, can be used to calculate the scleral radius with high precision. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  3. Analysis of low-energy and high-frequency femtosecond laser for the construction of deep anterior donor corneal lamellae

    Directory of Open Access Journals (Sweden)

    Gustavo Victor

    2014-04-01

    Full Text Available Purpose: To evaluate the efficacy and reliability of a low-energy femtosecond laser with a high repetition rate for construction of deep anterior donor corneal lamellae. Methods: This was a prospective laboratory investigation. Twenty-five human corneal buttons were femtosecond laser cut to create thick anterior lamellae (diameter, 10mm; thickness, 500µm. The laser cuts were made using an LDV® femtosecond laser in a Ziemer® anterior chamber. To obtain a better edge, the lamellae were trephined with an 8mm trephine (Katena®. The central corneal thickness and the anterior lamellae were measured using a Mitutoyo® thickness gauge with an accuracy of 0.001mm. Results: The central thickness of the 25 corneas ranged from 500 to 705µm (mean, 584 ± 51µm. The thickness of the anterior lamellae ranged from 420 to 480µm (mean, 455 ± 12.7µm. The anterior lamellae diameters were 7.90 ± 0.1mm, and all laser cuts were round. The lamellar interfaces appeared regular by surgical microscopy. There were no cases of inter-lamellar adhesion. Conclusion: The LDV® femtosecond laser appears to be a safe and reliable instrument for cutting deep anterior lamellae from donor corneoscleral buttons. Minimal variation in donor lamellar depth with the laser will be useful for creating donor corneal tissue for deeper anterior lamellar keratoplasty or endothelial keratoplasty surgery or both from a single donor cornea.

  4. Anterior and posterior ocular biometry in healthy Chinese subjects: data based on AS-OCT and SS-OCT.

    Directory of Open Access Journals (Sweden)

    Wenbin Huang

    Full Text Available To measure the anterior and posterior ocular biometric characteristics concurrently and to determine the relationship between the iris and choroid in healthy Chinese subjects.A total of 148 subjects (270 eyes were enrolled in this cross-section study. The anterior and posterior ocular biometric characteristics were measured simultaneously by anterior segment optical coherence tomography (AS-OCT and swept-source optical coherence tomography (SS-OCT.Compared with male eyes, female eyes had narrower anterior biometric parameters that presented with smaller anterior segment parameters [including anterior chamber depth (ACD, width (ACW, area (ACA, and volume (ACV; (all p<0.001], narrower anterior chamber angle parameters [including angle opening distance (AOD750, trabecular-iris space area (TISA750, and angle recess area (ARA; (all p<0.001], higher iris curvature (ICURV (p = 0.003, and larger lens vaults (LV (p = 0.019. These anterior ocular biometric parameters were correlated with increasing age (p<0.01. Iris thickness (IT750 and iris area (IAREA were associated with age, ACW, and pupil diameter (all p<0.05, while choroidal thickness (CT was associated with age, gender, and axial length (all p<0.05. Univariate regression analysis showed that greater CT was significantly associated with smaller IAREA (p = 0.026.Compared with male eyes, female eyes had narrower anterior biometric parameters that correlated with increasing age, which would be helpful in explaining the higher prevalence of angle closure rates in the female gender and in aging people. Increased CT might be associated with smaller iris area; however, this possibility needs to be investigated in future studies before this conclusion is made.

  5. Doriot Climatic Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — The Doriot Climatic Chambers are two, 60-feet long, 11-feet high, 15-feet wide chambers that are owned and operated by NSRDEC. The Doriot Climatic Chambers are among...

  6. Biometric analysis of pigment dispersion syndrome using anterior segment optical coherence tomography.

    Science.gov (United States)

    Aptel, Florent; Beccat, Sylvain; Fortoul, Vincent; Denis, Philippe

    2011-08-01

    To compare anterior chamber volume (ACV), iris volume, and iridolenticular contact (ILC) area before and after laser peripheral iridotomy (LPI) in eyes with pigment dispersion syndrome (PDS) using anterior segment optical coherence tomography (AS OCT) and image processing software. Cross-sectional study. Eighteen eyes of 18 patients with PDS; 30 eyes of 30 controls matched for age, gender, and refraction. Anterior segment OCT imaging was performed in all eyes before LPI and 1, 4, and 12 weeks after LPI. At each visit, 12 cross-sectional images of the AS were taken: 4 in bright conditions with accommodation (accommodation), 4 in bright conditions without accommodation (physiological miosis), and 4 under dark conditions (physiologic mydriasis). Biometric parameters were estimated using AS OCT radial sections and customized image-processing software. Anterior chamber volume, iris volume-to-length ratio, ILC area, AS OCT anterior chamber depth, and A-scan ultrasonography axial length. Before LPI, PDS eyes had a significantly greater ACV and ILC area than control eyes (Piris volume-to-length ratio than the controls (Piris volume-to-length ratio increased significantly (Pbiometric changes were stable over time. Iris volume-to-length ratio decreased significantly from accommodation to mydriasis and from miosis to mydriasis, both in PDS and control eyes (Piris that is abnormally large, relative to the AS size, but have a weakly resistant iris that is stretched and pushed against the lens when there is a pressure difference across the iris. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  7. Multiple chamber ionization detector

    International Nuclear Information System (INIS)

    Solomon, E.E.

    1980-01-01

    A multi-chambered ionisation detector enables the amount of radiation entering each chamber from a single radioactive, eg β, source to be varied by altering the proportion of the source protruding into each chamber. Electrodes define chambers and an extended radioactive source is movable to alter the source length in each chamber. Alternatively, the source is fixed relative to outer electrodes but the central electrode may be adjusted by an attached support altering the chamber dimensions and hence the length of source in each. Also disclosed are a centrally mounted source tiltable towards one or other chamber and a central electrode tiltable to alter chamber dimensions. (U.K.)

  8. Directed Energy Anechoic Chamber

    Data.gov (United States)

    Federal Laboratory Consortium — The Directed Energy Anechoic Chamber comprises a power anechoic chamber and one transverse electromagnetic cell for characterizing radiofrequency (RF) responses of...

  9. Anterior and posterior ocular biometry in healthy Chinese subjects: data based on AS-OCT and SS-OCT.

    Science.gov (United States)

    Huang, Wenbin; Gao, Xinbo; Li, Xingyi; Wang, Jiawei; Chen, Shida; Wang, Wei; Du, Shaolin; He, Mingguang; Zhang, Xiulan

    2015-01-01

    To measure the anterior and posterior ocular biometric characteristics concurrently and to determine the relationship between the iris and choroid in healthy Chinese subjects. A total of 148 subjects (270 eyes) were enrolled in this cross-section study. The anterior and posterior ocular biometric characteristics were measured simultaneously by anterior segment optical coherence tomography (AS-OCT) and swept-source optical coherence tomography (SS-OCT). Compared with male eyes, female eyes had narrower anterior biometric parameters that presented with smaller anterior segment parameters [including anterior chamber depth (ACD), width (ACW), area (ACA), and volume (ACV); (all piris space area (TISA750), and angle recess area (ARA); (all piris curvature (ICURV) (p = 0.003), and larger lens vaults (LV) (p = 0.019). These anterior ocular biometric parameters were correlated with increasing age (pIris thickness (IT750) and iris area (IAREA) were associated with age, ACW, and pupil diameter (all pbiometric parameters that correlated with increasing age, which would be helpful in explaining the higher prevalence of angle closure rates in the female gender and in aging people. Increased CT might be associated with smaller iris area; however, this possibility needs to be investigated in future studies before this conclusion is made.

  10. Reverse pupillary block after implantation of a scleral-sutured posterior chamber intraocular lens: a retrospective, open study.

    Science.gov (United States)

    Bang, Seung Pil; Joo, Choun-Ki; Jun, Jong Hwa

    2017-03-29

    To report the clinical features of patients with reverse pupillary block (RPB) after scleral-sutured posterior chamber intraocular lens (PC IOL) implantation and biometric changes after laser peripheral iridotomy (LPI). Eight patients attending our hospital's ophthalmology outpatient clinic, who developed RPB after implantation of a scleral-sutured PC IOL due to subluxation of the crystalline lens or IOL, were investigated in this retrospective, observational study. Preoperative evaluations showed angle pigmentation in all cases and iridodonesis in 2 cases. Two subjects had used an α 1A -adrenoceptor antagonist for benign prostatic hyperplasia. Pars plana or anterior partial vitrectomy was performed in all cases. All eyes showed an extremely deep anterior chamber, a concave iris configuration, and contact between the IOL optic and the iris at the pupillary margin. Pupil capture was detected in 2 cases. The mean (± SD) anterior chamber angle (ACA) was 89.91 ± 10.06°, and the anterior chamber depth (ACD) was 4.42 ± 0.16 mm before LPI. After LPI, the iris immediately became flat with a decreased ACA (51.70 ± 2.59°; P = 0.018) and ACD (4.14 ± 0.15 mm; P = 0.012). After LPI, the intraocular pressure decreased from 19.75 ± 3.77 mmHg to 15.63 ± 4.30 mmHg (P = 0.011), and the spherical equivalent decreased from -0.643 ± 0.385 D to - 0.875 ± 0.505 D (P = 0.016). Concomitant vitrectomy, angle pigmentation, and iridodonesis may be risk factors for RPB after scleral-sutured PC IOL implantation. LPI is effective for relieving the RPB.

  11. Assessment of anterior segment parameters under photopic and scotopic conditions in Indian eyes using anterior segment optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Dacosta Shaun

    2008-01-01

    Full Text Available Purpose: To compare the anterior segment parameters in photopic and scotopic conditions using anterior segment optical coherence tomography (AS OCT in Indian eyes. Materials and Methods: One hundred eyes of 100 normal subjects of both sexes, aged 19 to 76 years, underwent anterior segment evaluation by AS OCT (VisanteTM OCT. Central corneal thickness (CCT, central anterior chamber depth (ACD, pupil diameter (PD and the temporal and nasal peripheral irido-corneal angles were assessed in photopic and scotopic conditions. These anterior segment parameters were stratified for age, sex and refractive error. Results: Mean values of the parameters measured in photopic and scotopic conditions respectively were as follows: ACD (mm 2.88 ± 0.32, 2.89 ± 0.32 (P = 0.10; nasal angle (degrees 28.80 ± 5.91, 22.28 ± 7.50 (P < 0.001; temporal angle (degrees 29.95 ± 6.74, 22.82 ± 8.43 (P < 0.001; pupil diameter (mm 4.08 ± 0.91, 4.68 ± 0.92 (P < 0.001; CCT (µm 519 ± 33.88, 519 ± 33.88. Conclusions: There was no significant difference in the ACD in photopic and scotopic conditions. While the nasal and temporal angles showed a significant decrease, the pupil diameter showed a significant increase in scotopic conditions. Mean central ACD decreased with age and was shallower in females than in males. It was highest in myopes and lowest in hypermetropes. CCT was not influenced by photopic and scotopic conditions.

  12. Anterior segment optical coherence tomography parameters in subtypes of primary angle closure.

    Science.gov (United States)

    Guzman, Celeste P; Gong, Tianxia; Nongpiur, Monisha E; Perera, Shamira A; How, Alicia C; Lee, Hwee Kuan; Cheng, Li; He, Mingguang; Baskaran, Mani; Aung, Tin

    2013-08-07

    To compare anterior segment parameters, assessed by anterior segment optical coherence tomography (ASOCT), in subjects categorized as primary angle closure suspect (PACS), primary angle closure (PAC), primary angle closure glaucoma (PACG), and previous acute PAC (APAC); and to identify factors associated with APAC. This was a prospective ASOCT study of 425 subjects with angle closure (176 PACS, 66 PAC, 125 PACG, and 58 APAC). Customized software was used to measure ASOCT parameters, including angle opening distance (AOD750), trabecular-iris space area (TISA750), anterior chamber depth, width, area and volume (ACD, ACW, ACA, ACV), iris thickness (IT750), iris area (IAREA), and lens vault (LV). Mean differences in anterior segment parameters were evaluated by analysis of covariance (ANCOVA) adjusted for age, sex, and pupil diameter (PD). Comparison among the different subgroups showed that ACD, ACA, and ACV were smallest, and IT750 thickest in the APAC group compared with the other subgroups (P APAC group (1218 ± 34 μm) followed by PAC (860 ± 31 μm), PACG (845 ± 23 μm), and PACS (804 ± 19 μm), respectively (P = APAC group had the narrowest angles, the PACS group had the widest (P APAC. Eyes with APAC had the narrowest angles, smallest anterior segment dimensions, thickest iris, and largest LV compared with PACS, PAC, and PACG. LV, TISA750, and IT750 were the major determinants of APAC.

  13. Glove box chamber

    International Nuclear Information System (INIS)

    Cox, M.E.; Cox, M.E.

    1975-01-01

    An environmental chamber is described which enables an operator's hands to have direct access within the chamber without compromising a special atmosphere within such chamber. A pair of sleeves of a flexible material are sealed to the chamber around associated access apertures and project outwardly from such chamber. Each aperture is closed by a door which is openable from within the sleeve associated therewith so that upon an operator inserting his hand and arm through the sleeve, the operator can open the door to have access to the interior of the chamber. A container which is selectively separable from the remainder of the chamber is also provided to allow objects to be transferred from the chamber without such objects having to pass through the ambient atmosphere. An antechamber permitting objects to be passed directly into the chamber from the ambient atmosphere is included. (auth)

  14. Changes in intraocular pressure and anterior segment morphometry after uneventful phacoemulsification cataract surgery.

    LENUS (Irish Health Repository)

    Dooley, I

    2012-02-01

    PURPOSE: To study changes in anterior segment morphometry after uneventful phacoemulsification cataract surgery, and to investigate whether there is a relationship between any observed changes and intraocular pressure (IOP) reduction after the procedure. METHODS: The anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), central corneal thickness (CCT), and IOP were measured in 101 non-glaucomatous eyes before and after uneventful phacoemulsification cataract surgery. RESULTS: After cataract surgery, the mean ACD, ACV, and ACA values increased by 1.08 mm, 54.4 mm(3), and 13.1 degrees , respectively, and the mean IOP (corrected for CCT) decreased by 3.2 mm Hg. The predictive value of a previously described index (preoperative ACD\\/preoperative IOP (corrected for CCT) or CPD ratio) for IOP (corrected for CCT) reduction after cataract surgery was confirmed, reflected in an r(2) value of 23.3% between these two parameters (P<0.001). Other indices predictive of IOP reduction after cataract surgery were also identified, including preoperative IOP\\/preoperative ACV and preoperative IOP\\/preoperative ACA, reflected in r(2) values of 13.7 and 13.7%, respectively (P<0.001 and P<0.001, respectively). CONCLUSIONS: Our study confirms the predictive value of the CPD ratio for IOP reduction after cataract surgery, and may contribute to the decision-making process in patients with glaucoma or ocular hypertension. Furthermore, two novel indices of preoperative parameters that are predictive for IOP reduction after cataract surgery were identified, and enhance our understanding of the mechanisms underlying IOP changes after this procedure.

  15. The Boycott effect in magma chambers

    Science.gov (United States)

    Blanchette, F.; Peacock, T.; Bush, J. W. M.

    2004-03-01

    We investigate the plausibility of the stratified Boycott effect as a source of layering in magma chambers. Crystal settling within the magma chamber will generate buoyant fluid near the sloping sidewalls whose vertical ascent may be limited by the ambient stratification associated with vertical gradients in SiO2. The resulting flow may be marked by a layered structure, each layer taking the form of a convection cell spanning the lateral extent of the magma chamber. Using parameters relevant to magma chambers, we estimate that such convection cells would be established over a timescale of a month and have a depth on the order of 4m, which is roughly consistent with field observations of strata within solidified chambers.

  16. Anterior segment changes after pharmacologic mydriasis using Pentacam and optical coherence tomography in angle closure suspects

    Directory of Open Access Journals (Sweden)

    Jing-Min Guo

    2015-10-01

    Full Text Available AIM:To compare the dynamic changes of anterior segment parameters especially iris morphology induced by pharmacologic mydriasis between angle closure suspects and normal controls.METHODS:The study group comprised 19 eyes of 19 angle closure suspects and 19 eyes of 19 age- and sex-matched normal open-angle eyes. Pentacam and optical coherence tomography measurements before and 30min after instillation of compound tropicamide eye drop were performed and compared. Biometric evaluations of iris tomography and anterior chamber angle were estimated by a customized image-processing software.RESULTS:Baseline axial length, iris cross sectional area and volume did not differ significantly between angle closure suspects and normal controls. Angle closure suspects had smaller pupil size, narrower anterior segment dimension and axial length, thinner iris with greater curve in comparison with normal controls. Pharmacologic mydriasis led to significant increments in iris thickness at 750 μm, anterior chamber depth and volume, whereas significant decrements in iris curve, cross sectional area and volume in both groups. Angle opening distance at 500 μm was increased significantly in normal controls (from 0.465±0.115 mm to 0.539±0.167 mm, P=0.009, but not in angle closure suspects (from 0.125±0.100 mm to 0.145±0.131 mm, P=0.326. Iris volume change per millimeter of pupil dilation (△IV/△PD decreased significantly less in angle closure suspects than normal controls (-2.47±1.33 mm2 vs -3.63±1.58 mm2, P=0.019. Linear regression analysis showed that the change of angle opening distance at 500 μm was associated most with the change of central anterior chamber depth (β=0.841, P=0.002 and △IV/△PD (β=0.028, P=0.002, followed by gender (β=0.062, P=0.032.CONCLUSION:Smaller iris volume decrement per millimeter of pupil dilation is related significantly with the less anterior angle opening in angle closure suspects after pharmacologic mydriasis. Dynamic

  17. Comparison of anterior segment parameters between the acute primary angle closure eye and the fellow eye.

    Science.gov (United States)

    Lee, Jong Rak; Sung, Kyung Rim; Han, Seungbong

    2014-05-20

    To investigate features of the anterior segment (AS) of the affected eye compared to the fellow eye within the same patient in acute primary angle closure (APAC). Thirty-six patients with unilateral APAC were imaged with AS optical coherence tomography (OCT) before medical or laser treatment for the acute attack. Anterior chamber depth (ACD), iris curvature (IC), iris thickness at 750 μm from the scleral spur (IT750), lens vault (LV), anterior chamber area (ACA), and iris area were estimated by using ImageJ software (version 1.46). Conditional logistic regression analysis was performed to find the associated factors with the prediction of APAC. When compared to fellow eyes, affected eyes showed significantly shallower ACD (1.90 ± 0.24 and 1.55 ± 0.30 mm, respectively; P APAC. Greater LV was the most prominent feature of affected eyes compared to fellow eyes in APAC patients when assessed by AS OCT. This may play a role in the development of acute attack in primary angle closure. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  18. Big Bubble Deep Anterior Lamellar Keratoplasty for Management of Deep Fungal Keratitis

    Directory of Open Access Journals (Sweden)

    Hua Gao

    2014-01-01

    Full Text Available Objective. To evaluate the therapeutic effect of big bubble deep anterior lamellar keratoplasty (DALK in patients with deep fungal keratitis. Methods. Consecutive patients who had DALK for deep fungal keratitis at Shandong Eye Hospital between July 2011 and December 2012 were included. In all patients, the infiltration depth was more than 4/5ths of the corneal thickness. DALK surgery was performed with bare Descemet membrane (DM using the big bubble technique. Corrected distance visual acuity (CDVA, graft status, and intraoperative and postoperative complications were monitored. Results. Big bubble DALK was performed in 23 patients (23 eyes. Intraoperative perforation of the DM occurred in two eyes (8.7% during stromal dissection. The patients received lamellar keratoplasty with an air bubble injected into the anterior chamber. Double anterior chamber formed in 3 eyes (13.0%. Mean CDVA of the patients without cataract, amblyopia, and fungal recurrence was improved from preoperative HM/20 cm−1.0 (LogMAR to 0.23 ± 0.13 (LogMAR at the last followup (P<0.01. Fungal recurrence was found in two patients (8.7%. Corneal stromal graft rejection was noted in one patient (4.3%. Conclusions. DALK using the big bubble technique seems to be effective and safe in the treatment of deep fungal keratitis unresponsive to medication.

  19. bubble chamber lens

    CERN Multimedia

    Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  20. Comparison of Anterior Segment-Optical Coherence Tomography Parameters in Phacomorphic Angle Closure and Acute Angle Closure Eyes.

    Science.gov (United States)

    Moghimi, Sasan; Ramezani, Farshid; He, Mingguang; Coleman, Anne L; Lin, Shan C

    2015-12-01

    The purpose of this study is to compare anterior segment-optical coherence tomography (AS-OCT) parameters in phacomorphic angle closure and acute primary angle closure (APAC) eyes. In this cross-sectional case series, a total of 134 patients with phacomorphic angle closure (28 eyes) or APAC (54 eyes), as well as normal control subjects (52 eyes), were enrolled. Patients underwent AS-OCT imaging and A-scan biometry of both eyes. Anterior chamber depth (ACD), anterior chamber area (ACA), iris thickness (IT), iris curvature, lens vault (LV), anterior vault (AV), and angle parameters including angle opening distance (AOD 500 and AOD750) and trabecular iris space area (TISA500 and TISA750) were measured in qualified images using the Zhongshan Angle Assessment Program and compared among eyes with phacomorphic angle closure, APAC, and normal control subjects. Phacomorphic angle closure and APAC eyes had smaller AOD, ACD, ACA, ACW, AV, and posterior corneal arc length and greater LV than normal controls (P APAC eyes: ACD 1042 μm (OR,12.12; P APAC eyes. In multivariate analysis, ACD, LV, AOD500, and axial length could significantly distinguish the two entities. Ocular biometric parameters can differentiate phacomorphic angle closure from APAC eyes. Shallower ACD and greater LV, axial length, and ACA are the main parameters that distinguish phacomorphic angle closure from APAC.

  1. Dual ionization chamber

    International Nuclear Information System (INIS)

    Mallory, J.; Turlej, Z.

    1981-01-01

    Dual ionization chambers are provided for use with an electronic smoke detector. The chambers are separated by electrically-conductive partition. A single radiation source extends through the partition into both chambers, ionizing the air in each. The mid-point current of the device may be balanced by adjusting the position of the source

  2. Relationship between intraocular pressure and angle configuration: an anterior segment OCT study.

    Science.gov (United States)

    Chong, Rachel S; Sakata, Lisandro M; Narayanaswamy, Arun K; Ho, Sue-Wei; He, Mingguang; Baskaran, Mani; Wong, Tien Yin; Perera, Shamira A; Aung, Tin

    2013-03-05

    To assess the relationship between intraocular pressure (IOP) and anterior chamber angle (ACA) configuration as assessed by gonioscopy and anterior segment optical coherence tomography (AS-OCT). A total of 2045 subjects aged 50 years and older, were recruited from a community clinic and underwent AS-OCT, Goldmann applanation tonometry, and gonioscopy. A quadrant was classified as closed on gonioscopy if the posterior trabecular meshwork could not be seen. A closed quadrant on AS-OCT was defined by the presence of any contact between the iris and angle wall anterior to the scleral spur. Customized software (Zhongshan Angle Assessment Program, Guangzhou, China) was used to measure AS-OCT parameters on AS-OCT scans, including anterior chamber depth, area, and volume; iris thickness (IT) and curvature; lens vault; angle opening distance; and trabecular-iris space area. IOP values were adjusted for age, sex, diabetes and hypertension status, body mass index, central corneal thickness, and presence of peripheral anterior synechiae. Mean age of study subjects was 63.2 ± 8.0 years, 52.6% were female, and 89.4% were Chinese. Mean IOP was 14.8 ± 2.4 mm Hg (range 826). IOP (mean ± SE) increased with number of quadrants with gonioscopic angle closure (none: 14.6 ± 0.2; one: 14.7 ± 0.3; two: 15.0 ± 0.3; three: 15.0 ± 0.3; four: 15.6 ± 0.3 mm Hg; P measured on AS-OCT images, except for IT and lens vault. There was an association between the extent of angle closure, as assessed on AS-OCT and gonioscopy, with increasing IOP.

  3. Mush Column Magma Chambers

    Science.gov (United States)

    Marsh, B. D.

    2002-12-01

    Magma chambers are a necessary concept in understanding the chemical and physical evolution of magma. The concept may well be similar to a transfer function in circuit or time series analysis. It does what needs to be done to transform source magma into eruptible magma. In gravity and geodetic interpretations the causative body is (usually of necessity) geometrically simple and of limited vertical extent; it is clearly difficult to `see' through the uppermost manifestation of the concentrated magma. The presence of plutons in the upper crust has reinforced the view that magma chambers are large pots of magma, but as in the physical representation of a transfer function, actual magma chambers are clearly distinct from virtual magma chambers. Two key features to understanding magmatic systems are that they are vertically integrated over large distances (e.g., 30-100 km), and that all local magmatic processes are controlled by solidification fronts. Heat transfer considerations show that any viable volcanic system must be supported by a vertically extensive plumbing system. Field and geophysical studies point to a common theme of an interconnected stack of sill-like structures extending to great depth. This is a magmatic Mush Column. The large-scale (10s of km) structure resembles the vertical structure inferred at large volcanic centers like Hawaii (e.g., Ryan et al.), and the fine scale (10s to 100s of m) structure is exemplified by ophiolites and deeply eroded sill complexes like the Ferrar dolerites of the McMurdo Dry Valleys, Antarctica. The local length scales of the sill reservoirs and interconnecting conduits produce a rich spectrum of crystallization environments with distinct solidification time scales. Extensive horizontal and vertical mushy walls provide conditions conducive to specific processes of differentiation from solidification front instability to sidewall porous flow and wall rock slumping. The size, strength, and time series of eruptive behavior

  4. The Bern Infinitesimal Bubble Chamber (BIBC)

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    The chamber body was machined from a block of aluminium. The visible volume was cylindrical with 65 mm diameter and 35 mm depth. It was filled with propane or freon. It was meant as vertex detector in the search of short-lived particles. It was also used with in-line holography resulting in 8 µm bubble size and 9 cm depth of the field. See E. Ramseyer, B. Hahn and E. Hugentobler, Nucl. Instrum. Methods 201 (1982) 335.

  5. Anterior segment optical coherence tomography of acute primary angle closure.

    Science.gov (United States)

    Zhang, Hai Tao; Xu, Liang; Cao, Wei Fang; Wang, Ya Xing; Jonas, Jost B

    2010-06-01

    To assess anterior segment optical coherence tomographic measurements of patients after acute unilateral primary angle closure (APAC) compared with those of normal subjects. The clinical observational study included 41 hospital-based patients after unilateral APAC, their unaffected contralateral eyes, and 205 subjects. These were selected from the population-based Beijing Eye Study, and were matched with the APAC group for age, gender, and refractive error. All study participants underwent slit-lamp adapted optical coherence tomography (OCT). Compared with the unaffected contralateral eyes, eyes with APAC had a significantly shallower anterior chamber (P APAC and the unaffected contralateral eyes both showed more shallow anterior chambers (P APAC group, the anterior chamber angle was closed in three or more quadrants. Anterior segment OCT measurements show significant differences between eyes with APAC, contralateral eyes at risk for APAC, and normal eyes. This may open possibilities for a semi-automatic assessment of subjects at risk for APAC by anterior segment OCT. The anterior chamber angle was closed most often in the nasal quadrant, and, in APAC, the angle was closed in three or more quadrants.

  6. Prototype multiwire proportional chamber

    CERN Multimedia

    1975-01-01

    Chambers of this type were initially developed within the Alpha project (finally not approved). They were designed such to minimize the radiation length with a view to a mass spectrometer of high resolution meant to replace the Omega detector. The chambers were clearly forerunners for the (drift) chambers later built for R606 with the novel technique of crimping the wires. See also photo 7510039X.

  7. Streamer chamber: pion decay

    CERN Multimedia

    1992-01-01

    The real particles produced in the decay of a positive pion can be seen in this image from a streamer chamber. Streamer chambers consist of a gas chamber through which a strong pulsed electric field is passed, creating sparks as a charged particle passes through it. A magnetic field is added to cause the decay products to follow curved paths so that their charge and momentum can be measured.

  8. Electromagnetic reverberation chambers

    CERN Document Server

    Besnier, Philippe

    2013-01-01

    Dedicated to a complete presentation on all aspects of reverberation chambers, this book provides the physical principles behind these test systems in a very progressive manner. The detailed panorama of parameters governing the operation of electromagnetic reverberation chambers details various applications such as radiated immunity, emissivity, and shielding efficiency experiments.In addition, the reader is provided with the elements of electromagnetic theory and statistics required to take full advantage of the basic operational rules of reverberation chambers, including calibration proc

  9. DORIOT CLIMATIC CHAMBERS

    Data.gov (United States)

    Federal Laboratory Consortium — The Doriot Climatic Chambers reproduce environmental conditions occurring anywhere around the world. They provide an invaluable service by significantly reducing the...

  10. Refrigeration Test Chamber

    Data.gov (United States)

    Federal Laboratory Consortium — The enclosed and environmentally controlled chamber is able to test four units (single-phase) simultaneously at conditions ranging from tundra to desert temperatures...

  11. Surgical technique for explantation of cosmetic anterior chamber iris implants.

    Science.gov (United States)

    Arjmand, Parnian; Gooi, Patrick; Ahmed, Iqbal Ike K

    2015-01-01

    The Newcoloriris is a silicone implant for cosmetic alteration of iris color. Implantation is associated with significant ocular complications of decreased vision, glaucoma, and corneal edema. Although removal of the implant also entails risks, it is ultimately necessary to preserve vision. We describe a technique for removing the implant that may also reduce intraoperative complications. The implant is explanted using a bimanual technique with small incisions in 3 sections via a "slicing-the-pie" technique using iris microforceps, microscissors, and microinstrumentation. Our patient required removal 5 years after implantation, which is the longest reported interval in the literature. This suggests that as long as these implants are present, ocular structures are at risk. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Changes in Anterior Segment Morphology of Iris Bombe before and after Laser Peripheral Iridotomy in Patients with Uveitic Secondary Glaucoma

    Directory of Open Access Journals (Sweden)

    Wakako Ikegawa

    2016-01-01

    Full Text Available Purpose. To quantify changes in anterior segment (AS parameters after laser peripheral iridotomy (LPI using AS-optical coherence tomography (OCT of iris bombe. Method. AS images of eight eyes were captured before and after iris bombe and more than 2 weeks after LPI (post-LPI using AS-OCT. We compared the following AS parameters: anterior chamber depth (ACD, anterior chamber volume (ACV, iris curvature (IC, iris thickness at 500 μm from the scleral spur (IT-1 in the middle between the iris root and pupillary margin (IT-2 and 500 μm from the pupillary margin (IT-3 to the anterior chamber angle (ACA (angle opening distance [AOD750], and trabecular iris space area. Results. Mean IT-1 and IT-3, but not IT-2, were lower after iris bombe (IT-1, P=0.001; IT-2, P=0.081; and IT-3, P=0.001. There were no significant differences between ACD at pre-LPI and before iris bombe (P=0.096. The mean ACV and AOD750 of iris bombe increased at post-LPI (ACV, P<0.01, and AOD750, P<0.05. The mean IT-1, IT-2, and IT-3 increased at post-LPI (all, P≤0.01. IC decreased at post-LPI (P<0.001, and ACD at post-LPI did not change. Conclusions. The iris extends and becomes thinner during iris bombe. LPI during bombe decreases the IC and increases the ACV and ACA.

  13. Climatic chamber ergometer

    CSIR Research Space (South Africa)

    Atkins, AR

    1968-01-01

    Full Text Available The design and calibration of an ergometer for exercising subjects during calorimetric studies in the climate chamber, are described. The ergometer is built into the climatic chamber and forms an integral part of the whole instrumentation system foe...

  14. bubble chamber lens

    CERN Multimedia

    Was used in a PS experiment. Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  15. BEBC bubble chamber

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    Looking up into the interior of BEBC bubble chamber from the expansion cylinder. At the top of the chamber two fish-eye lenses are installed and three other fish-eye ports are blanked off. In the centre is a heat exchanger.

  16. The Mobile Chamber

    Science.gov (United States)

    Scharfstein, Gregory; Cox, Russell

    2012-01-01

    A document discusses a simulation chamber that represents a shift from the thermal-vacuum chamber stereotype. This innovation, currently in development, combines the capabilities of space simulation chambers, the user-friendliness of modern-day electronics, and the modularity of plug-and-play computing. The Mobile Chamber is a customized test chamber that can be deployed with great ease, and is capable of bringing payloads at temperatures down to 20 K, in high vacuum, and with the desired metrology instruments integrated to the systems control. Flexure plans to lease Mobile Chambers, making them affordable for smaller budgets and available to a larger customer base. A key feature of this design will be an Apple iPad-like user interface that allows someone with minimal training to control the environment inside the chamber, and to simulate the required extreme environments. The feedback of thermal, pressure, and other measurements is delivered in a 3D CAD model of the chamber's payload and support hardware. This GUI will provide the user with a better understanding of the payload than any existing thermal-vacuum system.

  17. DELPHI time projection chamber

    CERN Document Server

    1989-01-01

    The time projection chamber is inserted inside the central detector of the DELPHI experiment. Gas is ionised in the chamber as a charged particle passes through, producing an electric signal from which the path of the particle can be found. DELPHI, which ran from 1989 to 2000 on the LEP accelerator, was primarily concerned with particle identification.

  18. Anterior Horn Cell Diseases

    Directory of Open Access Journals (Sweden)

    Merve Firinciogullari

    2016-09-01

    Full Text Available The anterior horn cells control all voluntary movement. Motor activity, respiratory, speech, and swallowing functions are dependent upon signals from the anterior horn cells. Diseases that damage the anterior horn cells, therefore, have a profound impact. Symptoms of anterior horn cell loss (weakness, falling, choking lead patients to seek medical attention. In this article, anterior horn diseases were reviewed, diagnostic criteria and management were discussed in detail. [Archives Medical Review Journal 2016; 25(3.000: 269-303

  19. OPAL Jet Chamber Prototype

    CERN Multimedia

    OPAL was one of the four experiments installed at the LEP particle accelerator from 1989 - 2000. OPAL's central tracking system consists of (in order of increasing radius) a silicon microvertex detector, a vertex detector, a jet chamber, and z-chambers. All the tracking detectors work by observing the ionization of atoms by charged particles passing by: when the atoms are ionized, electrons are knocked out of their atomic orbitals, and are then able to move freely in the detector. These ionization electrons are detected in the dirfferent parts of the tracking system. This piece is a prototype of the jet chambers

  20. PS wire chamber

    CERN Document Server

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  1. Miniature ionization chamber

    International Nuclear Information System (INIS)

    Alexeev, V.I.; Emelyanov, I.Y.; Ivanov, V.M.; Konstantinov, L.V.; Lysikov, B.V.; Postnikov, V.V.; Rybakov, J.V.

    1976-01-01

    A miniature ionization chamber having a gas-filled housing which accommodates a guard electrode made in the form of a hollow perforated cylinder is described. The cylinder is electrically associated with the intermediate coaxial conductor of a triaxial cable used as the lead-in of the ionization chamber. The gas-filled housing of the ionization chamber also accommodates a collecting electrode shaped as a rod electrically connected to the center conductor of the cable and to tubular members. The rod is disposed internally of the guard electrode and is electrically connected, by means of jumpers passing through the holes in the guard electrode, to the tubular members. The tubular members embrace the guard electrode and are spaced a certain distance apart along its entire length. Arranged intermediate of these tubular members are spacers secured to the guard electrode and fixing the collecting electrode throughout its length with respect to the housing of the ionization chamber

  2. Optical spark chamber

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    An optical spark chamber developed for use in the Omega spectrometer. On the left the supporting frame is exceptionally thin to allow low momentum particles to escape and be detected outside the magnetic field.

  3. ALICE Time Projection Chamber

    CERN Multimedia

    Lippmann, C

    2013-01-01

    The Time Projection Chamber (TPC) is the main device in the ALICE 'central barrel' for the tracking and identification (PID) of charged particles. It has to cope with unprecedented densities of charges particles.

  4. Vacuum chamber 'bicone'

    CERN Multimedia

    1977-01-01

    This chamber is now in the National Museum of History and Technology, Smithsonian Institution, Washington, DC, USA, where it was exposed in an exhibit on the History of High Energy Accelerators (1977).

  5. Gridded Ionization Chamber

    International Nuclear Information System (INIS)

    Manero Amoros, F.

    1962-01-01

    In the present paper the working principles of a gridded ionization chamber are given, and all the different factors that determine its resolution power are analyzed in detail. One of these devices, built in the Physics Division of the JEN and designed specially for use in measurements of alpha spectroscopy, is described. finally the main applications, in which the chamber can be used, are shown. (Author) 17 refs

  6. Bubble chamber: antiproton annihilation

    CERN Multimedia

    1971-01-01

    These images show real particle tracks from the annihilation of an antiproton in the 80 cm Saclay liquid hydrogen bubble chamber. A negative kaon and a neutral kaon are produced in this process, as well as a positive pion. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that had been heated to boiling point.

  7. Sleeve reaction chamber system

    Science.gov (United States)

    Northrup, M Allen [Berkeley, CA; Beeman, Barton V [San Mateo, CA; Benett, William J [Livermore, CA; Hadley, Dean R [Manteca, CA; Landre, Phoebe [Livermore, CA; Lehew, Stacy L [Livermore, CA; Krulevitch, Peter A [Pleasanton, CA

    2009-08-25

    A chemical reaction chamber system that combines devices such as doped polysilicon for heating, bulk silicon for convective cooling, and thermoelectric (TE) coolers to augment the heating and cooling rates of the reaction chamber or chambers. In addition the system includes non-silicon-based reaction chambers such as any high thermal conductivity material used in combination with a thermoelectric cooling mechanism (i.e., Peltier device). The heat contained in the thermally conductive part of the system can be used/reused to heat the device, thereby conserving energy and expediting the heating/cooling rates. The system combines a micromachined silicon reaction chamber, for example, with an additional module/device for augmented heating/cooling using the Peltier effect. This additional module is particularly useful in extreme environments (very hot or extremely cold) where augmented heating/cooling would be useful to speed up the thermal cycling rates. The chemical reaction chamber system has various applications for synthesis or processing of organic, inorganic, or biochemical reactions, including the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction.

  8. Target Chamber Manipulator

    Science.gov (United States)

    Tantillo, Anthony; Watson, Matthew

    2015-11-01

    A system has been developed to allow remote actuation of sensors in a high vacuum target chamber used with a particle accelerator. Typically, sensors of various types are placed into the target chamber at specific radial and angular positions relative to the beam line and target. The chamber is then evacuated and the experiments are performed for those sensor positions. Then, the chamber is opened, the sensors are repositioned to new angles or radii, and the process is repeated, with a separate pump-down cycle for each set of sensor positions. The new sensor positioning system allows scientists to pre-set the radii of up to a dozen sensors, and then remotely actuate their angular positions without breaking the vacuum of the target chamber. This reduces the time required to reposition sensors from 6 hours to 1 minute. The sensors are placed into one of two tracks that are separately actuated using vacuum-grade stepping motors. The positions of the sensors are verified using absolute optical rotary encoders, and the positions are accurate to 0.5 degrees. The positions of the sensors are electronically recorded and time-stamped after every change. User control is through a GUI using LabVIEW.

  9. DELPHI Barrel Muon Chamber Module

    CERN Multimedia

    1989-01-01

    The module was used as part of the muon identification system on the barrel of the DELPHI detector at LEP, and was in active use from 1989 to 2000. The module consists of 7 individual muons chambers arranged in 2 layers. Chambers in the upper layer are staggered by half a chamber width with respect to the lower layer. Each individual chamber is a drift chamber consisting of an anode wire, 47 microns in diameter, and a wrapped copper delay line. Each chamber provided 3 signal for each muon passing through the chamber, from which a 3D space-point could be reconstructed.

  10. The KLOE drift chamber

    CERN Document Server

    Adinolfi, M; Ambrosino, F; Andryakov, A; Antonelli, A; Antonelli, M; Anulli, F; Bacci, C; Bankamp, A; Barbiellini, G; Bellini, F; Bencivenni, G; Bertolucci, Sergio; Bini, C; Bloise, C; Bocci, V; Bossi, F; Branchini, P; Bulychjov, S A; Cabibbo, G; Calcaterra, A; Caloi, R; Campana, P; Capon, G; Carboni, G; Cardini, A; Casarsa, M; Cataldi, G; Ceradini, F; Cervelli, F; Cevenini, F; Chiefari, G; Ciambrone, P; Conetti, S; Conticelli, S; Lucia, E D; Robertis, G D; Sangro, R D; Simone, P D; Zorzi, G D; Dell'Agnello, S; Denig, A; Domenico, A D; Donato, C D; Falco, S D; Doria, A; Drago, E; Elia, V; Erriquez, O; Farilla, A; Felici, G; Ferrari, A; Ferrer, M L; Finocchiaro, G; Forti, C; Franceschi, A; Franzini, P; Gao, M L; Gatti, C; Gauzzi, P; Giovannella, S; Golovatyuk, V; Gorini, E; Grancagnolo, F; Grandegger, W; Graziani, E; Guarnaccia, P; Von Hagel, U; Han, H G; Han, S W; Huang, X; Incagli, M; Ingrosso, L; Jang, Y Y; Kim, W; Kluge, W; Kulikov, V; Lacava, F; Lanfranchi, G; Lee-Franzini, J; Lomtadze, F; Luisi, C; Mao Chen Sheng; Martemyanov, M; Matsyuk, M; Mei, W; Merola, L; Messi, R; Miscetti, S; Moalem, A; Moccia, S; Moulson, M; Müller, S; Murtas, F; Napolitano, M; Nedosekin, A; Panareo, M; Pacciani, L; Pagès, P; Palutan, M; Paoluzi, L; Pasqualucci, E; Passalacqua, L; Passaseo, M; Passeri, A; Patera, V; Petrolo, E; Petrucci, Guido; Picca, D; Pirozzi, G; Pistillo, C; Pollack, M; Pontecorvo, L; Primavera, M; Ruggieri, F; Santangelo, P; Santovetti, E; Saracino, G; Schamberger, R D; Schwick, C; Sciascia, B; Sciubba, A; Scuri, F; Sfiligoi, I; Shan, J; Silano, P; Spadaro, T; Spagnolo, S; Spiriti, E; Stanescu, C; Tong, G L; Tortora, L; Valente, E; Valente, P; Valeriani, B; Venanzoni, G; Veneziano, Stefano; Wu, Y; Xie, Y G; Zhao, P P; Zhou, Y

    2001-01-01

    The tracking detector of the KLOE experiment is 4 m diameter, 3.3 m length drift chamber, designed to contain a large fraction of the decays of low-energy K sub L produced at the Frascati DAPHINE phi-factory. The chamber is made by a thin carbon fiber structure and operated with a helium-based gas mixture in order to minimise conversion of low-energy photons and multiple scattering inside the sensitive volume. The tracking information is provided by 58 layers of stereo wires defing 12,582 cells, 2x2 cm sup 2 in size in the 12 innermost layers and 3x3 cm sup 2 in the outer ones. Details of the chamber design, calibration procedure and tracking performances are presented.

  11. The KLOE drift chamber

    International Nuclear Information System (INIS)

    Adinolfi, M.; Aloisio, A.; Ambrosino, F.; Andryakov, A.; Antonelli, A.; Antonelli, M.; Anulli, F.; Bacci, C.; Bankamp, A.; Barbiellini, G.; Bellini, F.; Bencivenni, G.; Bertolucci, S.; Bini, C.; Bloise, C.; Bocci, V.; Bossi, F.; Branchini, P.; Bulychjov, S.A.; Cabibbo, G.; Calcaterra, A.; Caloi, R.; Campana, P.; Capon, G.; Carboni, G.; Cardini, A.; Casarsa, M.; Cataldi, G.; Ceradini, F.; Cervelli, F.; Cevenini, F.; Chiefari, G.; Ciambrone, P.; Conetti, S.; Conticelli, S.; Lucia, E. De; Robertis, G. De; Sangro, R. De; Simone, P. De; Zorzi, G. De; Dell'Agnello, S.; Denig, A.; Domenico, A. Di; Donato, C. Di; Falco, S. Di; Doria, A.; Drago, E.; Elia, V.; Erriquez, O.; Farilla, A.; Felici, G.; Ferrari, A.; Ferrer, M.L.; Finocchiaro, G.; Forti, C.; Franceschi, A.; Franzini, P.; Gao, M.L.; Gatti, C.; Gauzzi, P.; Giovannella, S.; Golovatyuk, V.; Gorini, E.; Grancagnolo, F.; Grandegger, W.; Graziani, E.; Guarnaccia, P.; Hagel, U.V.; Han, H.G.; Han, S.W.; Huang, X.; Incagli, M.; Ingrosso, L.; Jang, Y.Y.; Kim, W.; Kluge, W.; Kulikov, V.; Lacava, F.; Lanfranchi, G.; Lee-Franzini, J.; Lomtadze, F.; Luisi, C.; Mao, C.S.; Martemianov, M.; Matsyuk, M.; Mei, W.; Merola, L.; Messi, R.; Miscetti, S.; Moalem, A.; Moccia, S.; Moulson, M.; Mueller, S.; Murtas, F.; Napolitano, M.; Nedosekin, A.; Panareo, M.; Pacciani, L.; Pages, P.; Palutan, M.; Paoluzi, L.; Pasqualucci, E.; Passalacqua, L.; Passaseo, M.; Passeri, A.; Patera, V.; Petrolo, E.; Petrucci, G.; Picca, D.; Pirozzi, G.; Pistillo, C.; Pollack, M.; Pontecorvo, L.; Primavera, M.; Ruggieri, F.; Santangelo, P.; Santovetti, E.; Saracino, G.; Schamberger, R.D.; Schwick, C.; Sciascia, B.; Sciubba, A.; Scuri, F.; Sfiligoi, I.; Shan, J.; Silano, P.; Spadaro, T.; Spagnolo, S.; Spiriti, E.; Stanescu, C.; Tong, G.L.; Tortora, L.; Valente, E.; Valente, P.; Valeriani, B.; Venanzoni, G.; Veneziano, S.; Wu, Y.; Xie, Y.G.; Zhao, P.P.; Zhou, Y.

    2001-01-01

    The tracking detector of the KLOE experiment is 4 m diameter, 3.3 m length drift chamber, designed to contain a large fraction of the decays of low-energy K L produced at the Frascati DAPHINE phi-factory. The chamber is made by a thin carbon fiber structure and operated with a helium-based gas mixture in order to minimise conversion of low-energy photons and multiple scattering inside the sensitive volume. The tracking information is provided by 58 layers of stereo wires defing 12,582 cells, 2x2 cm 2 in size in the 12 innermost layers and 3x3 cm 2 in the outer ones. Details of the chamber design, calibration procedure and tracking performances are presented

  12. Multiple chamber ionization detector

    International Nuclear Information System (INIS)

    Solomon, E.E.

    1982-01-01

    An ionization smoke detector employs a single radiation source in a construction comprising at least two chambers with a center or node electrode. The radioactive source is associated with this central electrode, and its positioning may be adjusted relative to the electrode to alter the proportion of the source that protrudes into each chamber. The source may also be mounted in the plane of the central electrode, and positioned relative to the center of the electrode. The central electrode or source may be made tiltable relative to the body of the detector

  13. micro strip gas chamber

    CERN Multimedia

    1998-01-01

    About 16 000 Micro Strip Gas Chambers like this one will be used in the CMS tracking detector. They will measure the tracks of charged particles to a hundredth of a millimetre precision in the region near the collision point where the density of particles is very high. Each chamber is filled with a gas mixture of argon and dimethyl ether. Charged particles passing through ionise the gas, knocking out electrons which are collected on the aluminium strips visible under the microscope. Such detectors are being used in radiography. They give higher resolution imaging and reduce the required dose of radiation.

  14. Charpak hemispherical wire chamber

    CERN Document Server

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  15. Comparison of anterior segment morphology following prophylactic laser peripheral iridotomy in Caucasian and Chinese eyes.

    Science.gov (United States)

    Lee, Roland Y; Kasuga, Toshimitsu; Cui, Qi N; Huang, Guofu; He, Mingguang; Lin, Shan C

    2014-07-01

    To compare anterior segment biometric parameters between Caucasians and Chinese before and after laser peripheral iridotomy. Prospective clinical cohort study. Caucasian and Chinese primary angle-closure suspects. Anterior segment optical coherence tomography images captured before and after laser peripheral iridotomy were analysed to measure anterior segment biometric parameters. Paired Student's t-tests were used for within-ethnic group comparisons. Univariate and linear mixed-effect regression models were used for between-ethnic group comparisons. Angle opening distance, angle recess area, iris thickness, iris curvature, anterior chamber area, anterior chamber volume and anterior chamber width. Caucasians had significantly greater preoperative angle recess area, anterior chamber width, and iris curvature and lower preoperative iris thickness compared to Chinese (P iris curvature were observed within both ethnic groups (P iris curvature did not differ between the two ethnic groups (P iris convexity after laser peripheral iridotomy. Although certain aspects of anterior segment anatomy differed between Caucasians and Chinese preoperatively, they did not translate into significant ethnic differences in the amount of laser peripheral iridotomy-induced changes in the anterior segment biometric parameters. © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  16. Large planar drift chambers

    CERN Document Server

    Marel, Gérard; Bréhin, S; Devaux, B; Diamant-Berger, Alain M; Leschevin, C; Maillard, J; Malbequi, Y; Martin, H; Patoux, A; Pelle, J; Plancoulaine, J; Tarte, Gérard; Turlay, René

    1977-01-01

    The authors describe 14 m/sup 2/ hexagonal planar drift chambers designed for the neutrino experiment of the CERN-Dortmund-Heidelberg- Saclay Collaboration. Details on mechanical construction, electronic read-out, results on efficiency and accuracy are presented. (6 refs).

  17. Improvements in ionization chambers

    International Nuclear Information System (INIS)

    Whetten, N.R.; Zubal, C.

    1980-01-01

    A method of reducing mechanical vibrations transmitted to the parallel plate electrodes of ionization chamber x-ray detectors, commonly used in computerized x-ray axial tomography systems, is described. The metal plate cathodes and anodes are mounted in the ionizable gas on dielectric sheet insulators consisting of a composite of silicone resin and glass fibres. (UK)

  18. LEP vacuum chamber, prototype

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    Final prototype for the LEP vacuum chamber, see 8305170 for more details. Here we see the strips of the NEG pump, providing "distributed pumping". The strips are made from a Zr-Ti-Fe alloy. By passing an electrical current, they were heated to 700 deg C.

  19. Review of straw chambers

    International Nuclear Information System (INIS)

    Toki, W.H.

    1990-03-01

    This is a review of straw chambers used in the HRS, MAC, Mark III, CLEO, AMY, and TPC e + e - experiments. The straws are 6--8 mm in diameter, operate at 1--4 atmospheres and obtain resolutions of 45--100 microns. The designs and constructions are summarized and possible improvements discussed

  20. Heavy liquid bubble chamber

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    The CERN Heavy liquid bubble chamber being installed in the north experimental hall at the PS. On the left, the 1180 litre body; in the centre the magnet, which can produce a field of 26 800 gauss; on the right the expansion mechanism.

  1. LEP Vacuum Chamber

    CERN Multimedia

    1983-01-01

    This is a cut-out of a LEP vacuum chamber for dipole magnets showing the beam channel and the pumping channel with the getter (NEG) strip and its insulating supports. A water pipe connected to the cooling channel can also be seen at the back.The lead radiation shield lining is also shown. See also 8305563X.

  2. MISSING: BUBBLE CHAMBER LENS

    CERN Multimedia

    2001-01-01

    Would the person who borrowed the large bubble chamber lens from the Microcosm workshops on the ISR please return it. This is a much used piece from our object archives. If anybody has any information about the whereabouts of this object, please contact Emma.Sanders@cern.ch Thank you

  3. Scanning bubble chamber pictures

    CERN Multimedia

    1974-01-01

    These were taken at the 2 m hydrogen bubble chamber. The photo shows an early Shiva system where the pre-measurements needed to qualify the event were done manually (cf photo 7408136X). The scanning tables were located in bld. 12. Gilberte Saulmier sits on foreground, Inge Arents at centre.

  4. Chamber Profile Measurement System.

    Science.gov (United States)

    1980-10-01

    travel with the proper electronics. Other features of tihe gage assembly are: 1. Micrometer controlled down chamber positioning of the master template to...pressure sensitive "stiff stick" for infinitely varying the rate of travel from zero to maximum. A manual vernier control is incorporated to permit fine

  5. Drift chamber detectors

    International Nuclear Information System (INIS)

    Duran, I.; Martinez Laso, L.

    1989-01-01

    A review of High Energy Physics detectors based on drift chambers is presented. The ionization, drift diffusion, multiplication and detection principles are described. Most common drift media are analysied, and a classification of the detectors according to its geometry is done. Finally the standard read-out methods are displayed and the limits of the spatial resolution are discussed. (Author)

  6. Drift Chambers detectors

    International Nuclear Information System (INIS)

    Duran, I.; Martinez laso, L.

    1989-01-01

    We present here a review of High Energy Physics detectors based on drift chambers. The ionization, drift diffusion, multiplication and detection principles are described. Most common drift media are analysed, and a classification of the detectors according to its geometry is done. Finally the standard read-out methods are displayed and the limits of the spatial resolution are discussed. (Author) 115 refs

  7. The KLOE drift chamber

    International Nuclear Information System (INIS)

    Ferrari, A.

    2002-01-01

    The design and construction of the large drift chamber of the KLOE experiment is presented. The track reconstruction is described, together with the calibration method and the monitoring systems. The stability of operation and the performance are studied with samples of e + e - , K S K L and K + K - events

  8. Liquid Wall Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Meier, W R

    2011-02-24

    The key feature of liquid wall chambers is the use of a renewable liquid layer to protect chamber structures from target emissions. Two primary options have been proposed and studied: wetted wall chambers and thick liquid wall (TLW) chambers. With wetted wall designs, a thin layer of liquid shields the structural first wall from short ranged target emissions (x-rays, ions and debris) but not neutrons. Various schemes have been proposed to establish and renew the liquid layer between shots including flow-guiding porous fabrics (e.g., Osiris, HIBALL), porous rigid structures (Prometheus) and thin film flows (KOYO). The thin liquid layer can be the tritium breeding material (e.g., flibe, PbLi, or Li) or another liquid metal such as Pb. TLWs use liquid jets injected by stationary or oscillating nozzles to form a neutronically thick layer (typically with an effective thickness of {approx}50 cm) of liquid between the target and first structural wall. In addition to absorbing short ranged emissions, the thick liquid layer degrades the neutron flux and energy reaching the first wall, typically by {approx}10 x x, so that steel walls can survive for the life of the plant ({approx}30-60 yrs). The thick liquid serves as the primary coolant and tritium breeding material (most recent designs use flibe, but the earliest concepts used Li). In essence, the TLW places the fusion blanket inside the first wall instead of behind the first wall.

  9. Wire chamber conference

    International Nuclear Information System (INIS)

    Bartl, W.; Neuhofer, G.; Regler, M.

    1986-02-01

    This booklet contains program and the abstracts of the papers presented at the conference, most of them dealing with performance testing of various types of wire chambers. The publication of proceedings is planned as a special issue of 'Nuclear instruments and methods' later on. All abstracts are in English. An author index for the book of abstracts is given. (A.N.)

  10. Anterior Segment Ischemia after Strabismus Surger

    Directory of Open Access Journals (Sweden)

    Emine Seyhan Göçmen

    2017-01-01

    Full Text Available A 46-year-old male patient was referred to our clinic with complaints of diplopia and esotropia in his right eye that developed after a car accident. The patient had right esotropia in primary position and abduction of the right eye was totally limited. Primary deviation was over 40 prism diopters at near and distance. The patient was diagnosed with sixth nerve palsy and 18 months after trauma, he underwent right medial rectus muscle recession. Ten months after the first operation, full-thickness tendon transposition of the superior and inferior rectus muscles (with Foster suture was performed. On the first postoperative day, slit-lamp examination revealed corneal edema, 3+ cells in the anterior chamber and an irregular pupil. According to these findings, the diagnosis was anterior segment ischemia. Treatment with 0.1/5 mL topical dexamethasone drops (16 times/day, cyclopentolate hydrochloride drops (3 times/day and 20 mg oral fluocortolone (3 times/day was initiated. After 1 week of treatment, corneal edema regressed and the anterior chamber was clean. Topical and systemic steroid treatment was gradually discontinued. At postoperative 1 month, the patient was orthophoric and there were no pathologic symptoms besides the irregular pupil. Anterior segment ischemia is one of the most serious complications of strabismus surgery. Despite the fact that in most cases the only remaining sequel is an irregular pupil, serious circulation deficits could lead to phthisis bulbi. Clinical properties of anterior segment ischemia should be well recognized and in especially risky cases, preventative measures should be taken.

  11. CONGENITAL ANTERIOR TIBIOFEMURAL SUBLUXATION

    Directory of Open Access Journals (Sweden)

    A. Shahla

    2008-06-01

    Full Text Available Congenital anterior tibiofemoral subluxation is an extremely rare disorder. All reported cases accompanied by other abnormalities and syndromes. A 16-year-old high school girl referred to us with bilateral anterior tibiofemoral subluxation as the knees were extended and reduced at more than 30 degrees flexion. Deformities were due to tightness of the iliotibial band and biceps femuris muscles and corrected by surgical release. Associated disorders included bilateral anterior shoulders dislocation, short metacarpals and metatarsals, and right calcaneuvalgus deformity.

  12. Wire chamber gases

    International Nuclear Information System (INIS)

    Va'vra, J.

    1992-04-01

    In this paper, we describe new developments in gas mixtures which have occurred during the last 3--4 years. In particular, we discuss new results on the measurement and modeling of electron drift parameters, the modeling of drift chamber resolution, measurements of primary ionization and the choice of gas for applications such as tracking, single electron detection, X-ray detection and visual imaging. In addition, new results are presented on photon feedback, breakdown and wire aging

  13. Vienna Wire Chamber Conference

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    After those of 1978 and 1980, a third Wire Chamber Conference was held from 15-18 February in the Technical University of Vienna. Eight invited speakers covered the field from sophisticated applications in biology and medicine, via software, to the state of the art of gaseous detectors. In some forty other talks the speakers tackled in more detail the topics of gaseous detectors, calorimetry and associated electronics and software

  14. Double chambered right ventricle

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chul Koo; Yu, Yun Jeong; Yeon, Kyung Mo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1983-12-15

    Fourteen cases of double chambered right ventricle were diagnosed angiographically and of these nine cases were confirmed after operation and autopsy at Seoul National University Hospital in recent four years since 1979. The clinical and radiological findings with the emphasis on the cinecardiographic findings were analysed. The summaries of the analysis are as follows: 1. Among 14 cases, 6 cases were male and 8 cases were female. Age distribution was from 4 years to 36 years. 2. In chest x-ray findings, pulmonary vascularity was increased in 8 cases, decreased in 4 cases, and normal in 2 cases. Cardiomegaly was observed in 8 cases and other showed normal heart size. 3. In cinecardiography, 11 cases had interventricular septal defect. Among these 11 cases, VSD located in proximal high pressure chamber was in 2 cases and located in distal low pressure chamber was in 9 cases. 4. The location of aberrant muscle bundle in sinus portion of right ventricle was in 8 cases. In the rest 6 cases, the aberrant muscle bundle was located below the infundibulum of right ventricle. 5. For accurate diagnosis and differential diagnosis with other congenital cardiac anomalies such as Tetralogy of Fallot or isolated pulmonic stenosis, biplane cineangiography and catheterization is an essential procedure.

  15. Double chambered right ventricle

    International Nuclear Information System (INIS)

    Cho, Chul Koo; Yu, Yun Jeong; Yeon, Kyung Mo; Han, Man Chung

    1983-01-01

    Fourteen cases of double chambered right ventricle were diagnosed angiographically and of these nine cases were confirmed after operation and autopsy at Seoul National University Hospital in recent four years since 1979. The clinical and radiological findings with the emphasis on the cinecardiographic findings were analysed. The summaries of the analysis are as follows: 1. Among 14 cases, 6 cases were male and 8 cases were female. Age distribution was from 4 years to 36 years. 2. In chest x-ray findings, pulmonary vascularity was increased in 8 cases, decreased in 4 cases, and normal in 2 cases. Cardiomegaly was observed in 8 cases and other showed normal heart size. 3. In cinecardiography, 11 cases had interventricular septal defect. Among these 11 cases, VSD located in proximal high pressure chamber was in 2 cases and located in distal low pressure chamber was in 9 cases. 4. The location of aberrant muscle bundle in sinus portion of right ventricle was in 8 cases. In the rest 6 cases, the aberrant muscle bundle was located below the infundibulum of right ventricle. 5. For accurate diagnosis and differential diagnosis with other congenital cardiac anomalies such as Tetralogy of Fallot or isolated pulmonic stenosis, biplane cineangiography and catheterization is an essential procedure

  16. Argus target chamber

    International Nuclear Information System (INIS)

    Rienecker, F. Jr.; Glaros, S.S.; Kobierecki, M.

    1975-01-01

    A target chamber for application in the laser fusion program must satisfy some very basic requirements. (1) Provide a vacuum on the order of 10 -6 torr. (2) Support a microscopically small target in a fixed point in space and verify its location within 5 micrometers. (3) Contain an adjustable beam focusing system capable of delivering a number of laser beams onto the target simultaneously, both in time and space. (4) Provide access for diagnostics to evaluate the results of target irradiation. (5) Have flexibility to allow changes in targets, focusing optics and number of beams. The ARGUS laser which is now under construction at LLL will have a target chamber which meets these requirements in a simple economic manner. The chamber and auxiliary equipment are described, with reference to two double beam focusing systems; namely, lenses and ellipsoidal mirrors. Provision is made for future operation with four beams, using ellipsoidal mirrors for two-sided illumination and lens systems for tetragonal and tetrahedral irradiation

  17. Wire chambers: Trends and alternatives

    International Nuclear Information System (INIS)

    Regler, Meinhard

    1992-01-01

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!

  18. Criteria for controlled atmosphere chambers

    International Nuclear Information System (INIS)

    Robinson, J.N.

    1980-03-01

    The criteria for design, construction, and operation of controlled atmosphere chambers intended for service at ORNL are presented. Classification of chambers, materials for construction, design criteria, design, controlled atmosphere chamber systems, and operating procedures are presented. ORNL Safety Manual Procedure 2.1; ORNL Health Physics Procedure Manual Appendix A-7; and Design of Viewing Windows are included in 3 appendices

  19. Anterior ankle impingement

    NARCIS (Netherlands)

    Tol, Johannes L.; van Dijk, C. Niek

    2006-01-01

    The anterior ankle impingement syndrome is a clinical pain syndrome that is characterized by anterior ankle pain on (hyper) dorsiflexion. The plain radiographs often are negative in patients who have anteromedial impingement. An oblique view is recommended in these patients. Arthroscopic excision of

  20. Vacuum Chambers for LEP sections

    CERN Multimedia

    1983-01-01

    The picture shows sections of the LEP vacuum chambers to be installed in the dipole magnets (left) and in the quadrupoles (right). The dipole chamber has three channels: the beam chamber, the pumping duct where the NEG (non-evaporabe getter) is installed and the water channel for cooling (on top in the picture). The pumping duct is connected to the beam chamber through holes in the separating wall. The thick lead lining to shield radiation can also be seen. These chambers were manufactured as extruded aluminium alloy profiles.

  1. Cataract Surgery in Anterior Megalophthalmos: A Review

    Science.gov (United States)

    GALVIS, Virgilio; TELLO, Alejandro; M. RANGEL, Carlos

    2015-01-01

    Anterior megalophthalmos is characterized by megalocornea associated with a very broad anterior chamber and ciliary ring elongation. It is also called X-linked megalocornea. It is accompanied by early development of cataracts, zonular anomalies, and, rarely, vitreoretinal disorders. Subluxation of a cataract can occur in cataract surgery because of zonular weakness. In addition, in most patients, standard intraocular lens (IOL) decentration is a risk because of the enlarged sulcus and capsular bag. These unique circumstances make cataract surgery challenging. To date, several approaches have been developed. Implantation of a retropupillary iris-claw aphakic intraocular lens may be a good option because it is easier than suturing the IOL and can have better and more stable anatomic and visual outcomes, compared to other techniques. PMID:27350950

  2. Space plasma simulation chamber

    International Nuclear Information System (INIS)

    1986-01-01

    Scientific results of experiments and tests of instruments performed with the Space Plasma Simulation Chamber and its facility are reviewed in the following six categories. 1. Tests of instruments on board rockets, satellites and balloons. 2. Plasma wave experiments. 3. Measurements of plasma particles. 4. Optical measurements. 5. Plasma production. 6. Space plasms simulations. This facility has been managed under Laboratory Space Plasma Comittee since 1969 and used by scientists in cooperative programs with universities and institutes all over country. A list of publications is attached. (author)

  3. Stability of Streamer Chamber

    Science.gov (United States)

    Wada, Toshiaki; Ogawa, Masato; Takahashi, Kaoru; Sugiyama, Tsunetoshi; Kobayashi, Shigeharu; Kohno, Hirobumi

    1982-08-01

    The quality of tracks obtained from a streamer chamber is studied through the measurement of the streamer brightness. The stability of streamer tracks depends on the value of the high voltage applied and its shape. By using a single conical-type spark gap as the pulse shaper, stable brightness of the streamer tracks is attained. The data on the streamer brightness are compared with the result by Bulos et al. and it is found that the brightness is more strongly affected by field parameters than in their result.

  4. Stability of streamer chamber

    International Nuclear Information System (INIS)

    Wada, Toshiaki; Ogawa, Masato; Takahashi, Kaoru; Sugiyama, Tsunetoshi; Kobayashi, Shigeharu; Kohno, Hirobumi.

    1982-01-01

    The quality of tracks obtained from a streamer chamber is studied through the measurement of the streamer brightness. The stability of streamer tracks depends on the value of the high voltage applied and its shape. By using a single conical-type spark gap as the pulse shaper, stable brightness of the streamer tracks is attained. The data on the streamer brightness are compared with the result by Bulos et al. and it is found that the brightness is more strongly affected by field parameters than in their result. (author)

  5. Responses of the Ocular Anterior Segment and Refraction to 0.5% Tropicamide in Chinese School-Aged Children of Myopia, Emmetropia, and Hyperopia

    Directory of Open Access Journals (Sweden)

    Ying Yuan

    2015-01-01

    Full Text Available Purpose. To investigate the changes of anterior segment after cycloplegia and estimate the association of such changes with the changes of refraction in Chinese school-aged children of myopia, emmetropia, and hyperopia. Methods. 309 children were recruited and eligible subjects were assigned to three groups: hyperopia, emmetropia, or myopia. Cycloplegia was achieved with five cycles of 0.5% tropicamide. The Pentacam system was used to measure the parameters of interest before and after cycloplegia. Results. In the myopic group, the lenses were thinner and the lens position was significantly more posterior than that of the emmetropic and hyperopic groups in the cycloplegic status. The correlations between refraction and lens thickness (age adjusted; r=0.26, P<0.01, and lens position (age adjusted; r=-0.31, P<0.01 were found. After cycloplegia, ACD and ACV significantly increased, while ACA significantly decreased. Changes in refraction, ACD, ACV, and ACA were significantly different among the three groups (P<0.05, all. Changes of refraction were correlated with changes of ACD (r=0.41, P<0.01. Conclusions. Myopia presented thinner lenses and smaller changes of anterior segment and refraction after cycloplegia when compared to emmetropia and hyperopia. Changes of anterior chamber depth were correlated with refraction changes. This may contribute to a better understanding of the relationship between anterior segment and myopia.

  6. Council Chamber exhibition

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    To complete the revamp of CERN’s Council Chamber, a new exhibition is being installed just in time for the June Council meetings.   Panels will showcase highlights of CERN’s history, using some of the content prepared for the exhibitions marking 50 years of the PS, which were displayed in the main building last November. The previous photo exhibition in the Council Chamber stopped at the 1970s. To avoid the new panels becoming quickly out of date, photos are grouped together around specific infrastructures, rather than following a classic time-line. “We have put the focus on the accelerators – the world-class facilities that CERN has been offering researchers over the years, from the well-known large colliders to the lesser-known smaller facilities,” says Emma Sanders, who worked on the content. The new exhibition will be featured in a future issue of the Bulletin with photos and an interview with Fabienne Marcastel, designer of the exhibit...

  7. Time projection chamber

    International Nuclear Information System (INIS)

    Kamae, Tsuneyoshi

    1984-01-01

    A time projection chamber (TPC) was developed at Lawrence Berkeley Laboratory to compensate the shortcoming of drift chambers. The characteristics of the TPC are the improvement of the distortion of the trace of particles in long drift, the improvement of particle identification by taking out the analog signal proportional to the number of electrons, and the improvement of the method to analyze the three-dimensional analog signal. Two large TPC's are designed and manufactured in Japan. The details of these TPC's are explained in this paper. The results of test experiment are as follows. The accuracy of the measurement of particle position was about 100 micrometer in the r-theta plane and about 340 micrometer in the Z-direction. The accuracy of the measurement of ionization loss (dE/dx) was less than 4.0 percent. The reconstruction of quark pair production can be made. At present, the identification of K-mesons in jet phenomena is possible, and the cross-sections of inclusive processes are easily obtained. (Kato, T.)

  8. Estimation of axial curvature of anterior sclera: correlation between axial length and anterior scleral curvature as affected by angle kappa.

    Science.gov (United States)

    Lee, Sang-Mok; Choi, Hyuk Jin; Choi, Heejin; Kim, Mee Kum; Wee, Won Ryang

    2016-10-07

    BACKGROUND: Though the development and fitting of scleral contact lenses are expanding steadily, there is no simple method to provide scleral metrics for scleral contact lens fitting yet. The aim of this study was to establish formulae for estimation of the axial radius of curvature (ARC) of the anterior sclera using ocular biometric parameters that can be easily obtained with conventional devices. A semi-automated stitching method and a computational analysis tool for calculating ARC were developed by using the ImageJ and MATLAB software. The ARC of all the ocular surface points were analyzed from the composite horizontal cross-sectional images of the right eyes of 24 volunteers; these measurements were obtained using anterior segment optical coherence tomography for a previous study (AS-OCT; Visante). Ocular biometric parameters were obtained from the same volunteers with slit-scanning topography and partial coherence interferometry. Correlation analysis was performed between the ARC at 8 mm to the axis line (ARC[8]) and other ocular parameters (including age). With ARC obtained on several nasal and temporal points (7.0, 7.5, 8.0, 8.5, and 9.0 mm from the axis line), univariate and multivariate linear regression analyses were performed to develop a model for estimating ARC with the help of ocular biometric parameters. Axial length, spherical equivalent, and angle kappa showed correlations with temporal ARC[8] (tARC[8]; Pearson's r = 0.653, -0.579, and -0.341; P = 0.001, 0.015, and 0.015, respectively). White-to-white corneal diameter (WTW) and anterior chamber depth (ACD) showed correlation with nasal ARC[8] (nARC[8]; Pearson's r = -0.492 and -0.461; P = 0.015 and 0.023, respectively). The formulae for estimating scleral curvatures (tARC, nARC, and average ARC) were developed as a function of axial length, ACD, WTW, and distance from the axis line, with good determinant power (72 - 80 %; SPSS ver. 22.0). Angle kappa showed strong

  9. Effect of acupuncture depth on muscle pain

    Directory of Open Access Journals (Sweden)

    Kitakoji Hiroshi

    2011-06-01

    Full Text Available Abstract Background While evidence supports efficacy of acupuncture and/or dry needling in treating musculoskeletal pain, it is unclear which needling method is most effective. This study aims to determine the effects of depth of needle penetration on muscle pain. Methods A total of 22 healthy volunteers performed repeated eccentric contractions to induce muscle soreness in their extensor digital muscle. Subjects were assigned randomly to four groups, namely control group, skin group (depth of 3 mm: the extensor digital muscle, muscle group (depth of 10 mm: the extensor digital muscle and non-segmental group (depth of 10 mm: the anterior tibial muscle. Pressure pain threshold and electrical pain threshold of the skin, fascia and muscle were measured at a point 20 mm distal to the maximum tender point on the second day after the exercise. Results Pressure pain thresholds of skin group (depth of 3 mm: the extensor digital muscle and muscle group (depth of 10 mm: the extensor digital muscle were significantly higher than the control group, whereas the electrical pain threshold at fascia of muscle group (depth of 10 mm: the extensor digital muscle was a significantly higher than control group; however, there was no significant difference between the control and other groups. Conclusion The present study shows that acupuncture stimulation of muscle increases the PPT and EPT of fascia. The depth of needle penetration is important for the relief of muscle pain.

  10. Multiple Coronary Chamber Microfistulas or Persistent Thebesian Vessels?

    Directory of Open Access Journals (Sweden)

    Cernica Daniel

    2017-09-01

    Full Text Available Coronary fistulas are rare, not gender-specific congenital conditions, consisting of communications between the coronary arteries and either another coronary vessel or a cardiac chamber. In contrast to large fistulas, small fistulas, named “minimae cordis veneae” or the Thebesius venous system, are draining into heart chambers and form a vascular network in the cardiac lumen. In this article, we present the case of a 72-year-old female with a significant history of cardiovascular disease, admitted to our clinic because of rest dyspnea, fatigue, and minimal chest pain. The 12-lead electrocardiogram showed a trifascicular block (a second-degree atrioventricular block Mobitz II, associated with a right bundle branch block and left anterior fascicle block and negative T waves in DII, DIII, aVF, V4–V6 leads. An invasive coronary angiography was performed, which revealed no significant atherosclerotic lesions. However, a persistent capillary blush was present at the apex site of the left ventricular chamber, draining from the distal segments of both the anterior descending coronary artery and the posterior interventricular coronary artery. The intramural vascular network generating a left ventricle angiogram image of this kind was suggestive for persistent Thebesian vessels connecting the two coronaries with the left ventricular chamber.

  11. Michigan ATLAS MDT Chamber Mass Production

    CERN Document Server

    Diehl, E; Levin, D; McKee, S; Neal, H; Schick, H; Tarle, G; Thun, R; Weaverdyck, C; Xu, Q; Zhao, Z; Zhou, B

    2001-01-01

    This paper describes the ATLAS MDT precision muon chamber construction at the University of Michigan. The chamber assembly facilities, the jigging set up, alignment procedures, and other measurements necessary for chamber assembly are described. The chamber quality assurance monitoring procedures and data for the first year mass production are presented. The chamber gas system assembly facilities, and the chamber leak test procedure together with data also reported. The chamber production database, which monitors chamber production, is also discussed.

  12. Congenital anterior urethral diverticulum

    International Nuclear Information System (INIS)

    Jung, Hyun Sub; Chung, Young Sun; Suh, Chee Jang; Won, Jong Jin

    1985-01-01

    Two cases of congenital anterior urethral diverticular which have occurred in a 4 year old and one month old boy are presented. Etiology, diagnostic procedures, and its clinical results are briefly reviewed

  13. Anterior knee pain

    Science.gov (United States)

    ... thighbone where the kneecap normally rests is too shallow. You have flat feet. Anterior knee pain is ... the principles of the Health on the Net Foundation (www.hon.ch). The information provided herein should ...

  14. Diogene pictorial drift chamber

    International Nuclear Information System (INIS)

    Gosset, J.

    1984-01-01

    A pictorial drift chamber, called DIOGENE, has been installed at Saturne in order to study central collisions of high energy heavy ions. It has been adapted from the JADE internal detector, with two major differences to be taken into account. First, the center-of-mass of these collisions is not identical to the laboratory reference frame. Second, the energy loss and the momentum ranges of the particles to be detected are different from the ones in JADE. It was also tried to keep the cost as small as possible, hence the choice of minimum size and minimum number of sensitive wires. Moreover the wire planes are shifted from the beam axis: this trick helps very much to quickly reject the bad tracks caused by the ambiguity of measuring drift distances (positive or negative) through times (always positive)

  15. Peltier-based cloud chamber

    Science.gov (United States)

    Nar, Sevda Yeliz; Cakir, Altan

    2018-02-01

    Particles produced by nuclear decay, cosmic radiation and reactions can be identified through various methods. One of these methods that has been effective in the last century is the cloud chamber. The chamber makes visible cosmic particles that we are exposed to radiation per second. Diffusion cloud chamber is a kind of cloud chamber that is cooled by dry ice. This traditional model has some application difficulties. In this work, Peltier-based cloud chamber cooled by thermoelectric modules is studied. The new model provided uniformly cooled base of the chamber, moreover, it has longer lifetime than the traditional chamber in terms of observation time. This gain has reduced the costs which spent each time for cosmic particle observation. The chamber is an easy-to-use system according to traditional diffusion cloud chamber. The new model is portable, easier to make, and can be used in the nuclear physics experiments. In addition, it would be very useful to observe Muons which are the direct evidence for Lorentz contraction and time expansion predicted by Einsteins special relativity principle.

  16. Recombination chambers for BNCT dosimetry

    International Nuclear Information System (INIS)

    Tulik, Piotr

    2006-01-01

    Parallel plate recombination ionization chambers are known as the detectors which can be used for determination of gamma and high-LET dose components and for characterization of radiation quality of mixed radiation fields. Specially designed chambers can operate correctly even at dose rates of therapeutic beams. In this work the investigations were extended to a set of cylindrical chambers including a TE chamber and three graphite chambers filled with different gases - CO 2 , N 2 and 10 BF 3 , in order to determine the thermal neutrons, 14 N capture, gamma, and fast neutron dose components. The separation of the dose components is based on differences of the shape of the saturation curve, in dependence on LET spectrum of the investigated radiation. The measurements using all the chambers and a parallel plate recombination chamber were performed in a reactor beam of NRI Rez (Czech Republic). The gamma component was determined with accuracy of about 5%, while the variations of its value could be monitored with accuracy of about 0.5%. Relative changes of the beam components could be detected with accuracy of about 5% using the parallel plate chamber. The use of the chambers filled with different gases considerably improved the resolution of the method. (author)

  17. Bilateral spontaneous dislocation of posterior chamber intraocular lens in a patient with gyrate atrophy

    Directory of Open Access Journals (Sweden)

    Michael Kinori

    2012-01-01

    Full Text Available We report a patient with gyrate atrophy, a rare metabolic disease, who had bilateral late spontaneous posterior dislocation of in-the-bag posterior chamber intraocular lens (PCIOL. He underwent pars plana vitrectomy, PCIOL retrieval and anterior chamber intraocular lens implantation in both eyes. This report may imply that patients with gyrate atrophy are at risk for spontaneous dislocation of intraocular lenses.

  18. Measurements of anterior segment parameters using three different non-contact optical devices in keratoconus patients

    Directory of Open Access Journals (Sweden)

    Ahmet Taylan Yazıcı

    2013-08-01

    Full Text Available AIM: To evaluate the measurements of anterior segment parameters using three different non-contact optical devices in keratoconus patients.METHODS:A hundred and one eyes of 55 keratoconus patients were enrolled in this study. The mean age was 26.2±8.9 years. The inclusion criteria were keratoconus stage I to III according to the Amsler-Krumeich keratoconus classification. All the measurements were done by the same operator, under the mesopic light condition and repeated with three different optical methods; Visante , Orbscan and Pentacam. The evaluated anterior segment parameters were anterior chamber depth (ACD, central and thinnest corneal thickness (CCT and TCT and pupil diameter (PD.RESULTS: The mean CCT measured by Visante, Orbscan and Pentacam were as follows:462.0±48.1µm, 463.9±60.9µm, 476.5±45.3µm, respectively (P=0.873. The mean ACD values were 3.34±0.33mm, 3.26±0.33mm, 3.49±0.40mm, respectively (P=0.118. The mean PD measurements were 5.11±1.14mm, 4.80±0.85mm, 3.80±1.38mm, respectively (PP=0.214. The Visante and Orbscan measured CCT similarly, while Pentacam measured CCT thicker than the other two. The Visante measured TCT thinner than the other two devices. In ACD measurements, Orbscan was the one giving the lowest values. PD was measured differently by the devices.CONCLUSION: Although TCT, CCT and ACD measurements acquired by Visante, Orbscan and Pentacam in keratoconus patients are similar, PD measurements show large differences among the devices.

  19. Under-air staining of the anterior capsule using Trypan blue with a 30 G needle

    Directory of Open Access Journals (Sweden)

    Giammaria D

    2013-01-01

    Full Text Available Daniele Giammaria,1 Michele Giannotti,2 Angelo Scopelliti,1 Giacomo Pellegrini,1 Bruno Giannotti11Azienda Ospedaliera Ospedali Riuniti Marche Nord, Fano, Italy; 2Catholic University of Rome, Rome, ItalyAbstract: The original technique of staining the anterior capsule of the lens with Trypan blue involves the injection of an air bubble in the anterior chamber. A drawback of this technique is the possible instability of the anterior chamber caused by the sudden exit of air when the dye is injected with the cannula through the side-port incision. Other staining techniques that use viscoelastic substances to increase the stability of the anterior chamber and to dose the injected dye have been described. The authors present an under-air staining technique of the anterior capsule using one drop of Trypan blue injected with a 30 G needle through the peripheral cornea. This procedure prevents the air bubble from escaping the anterior chamber and allows fast and selective staining of the capsule.Keywords: Trypan blue, staining technique, dye, cataract surgery, capsulorhexis

  20. Depth absorbed dose distributions for electrons

    International Nuclear Information System (INIS)

    Fregene, A.O.

    1980-01-01

    There is controversy over the comparative depth dose distributions produced by 10 MeV microtron and linear accelerator electron beams. The arguments produced by Brahme and Svensson in their rejection of silicon diode and LiF depth dose measurements (1976, Phys. Med. Biol., vol. 21, 304; 1978, Phys. Med. Biol., vol. 23, 788) have been shown to be insubstantial. These depth dose measurements in fact confirm that the two types of electron beam are not significantly different at 10 MeV. The significant differences originally reported by Brahme et al. on the basis of liquid ionisation chamber measurements (Brahme, A., Hulten, G., and Svensson, H., 1975, Phys. Med. Biol., vol. 20, 39), and the implied clinical advantage of the microtron, therefore both remain in doubt. (UK)

  1. National Ignition Facility Target Chamber

    International Nuclear Information System (INIS)

    Wavrik, R W; Cox, J R; Fleming, P J

    2000-01-01

    On June 11, 1999 the Department of Energy dedicated the single largest piece of the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) in Livermore, California. The ten (10) meter diameter aluminum target high vacuum chamber will serve as the working end of the largest laser in the world. The output of 192 laser beams will converge at the precise center of the chamber. The laser beams will enter the chamber in two by two arrays to illuminate 10 millimeter long gold cylinders called hohlraums enclosing 2 millimeter capsule containing deuterium, tritium and isotopes of hydrogen. The two isotopes will fuse, thereby creating temperatures and pressures resembling those found only inside stars and in detonated nuclear weapons, but on a minute scale. The NIF Project will serve as an essential facility to insure safety and reliability of our nation's nuclear arsenal as well as demonstrating inertial fusion's contribution to creating electrical power. The paper will discuss the requirements that had to be addressed during the design, fabrication and testing of the target chamber. A team from Sandia National Laboratories (SNL) and LLNL with input from industry performed the configuration and basic design of the target chamber. The method of fabrication and construction of the aluminum target chamber was devised by Pitt-Des Moines, Inc. (PDM). PDM also participated in the design of the chamber in areas such as the Target Chamber Realignment and Adjustment System, which would allow realignment of the sphere laser beams in the event of earth settlement or movement from a seismic event. During the fabrication of the target chamber the sphericity tolerances had to be addressed for the individual plates. Procedures were developed for forming, edge preparation and welding of individual plates. Construction plans were developed to allow the field construction of the target chamber to occur parallel to other NIF construction activities. This was

  2. The CLEO III drift chamber

    CERN Document Server

    Peterson, D; Briere, R A; Chen, G; Cronin-Hennessy, D; Csorna, S; Dickson, M; Dombrowski, S V; Ecklund, K M; Lyon, A; Marka, S; Meyer, T O; Patterson, J R; Sadoff, A; Thies, P; Thorndike, E H; Urner, D

    2002-01-01

    The CLEO group at the Cornell Electron Storage Ring has constructed and commissioned a new central drift chamber. With 9796 cells arranged in 47 layers ranging in radius from 13.2 to 79 cm, the new drift chamber has a smaller outer radius and fewer wires than the drift chamber it replaces, but allows the CLEO tracking system to have improved momentum resolution. Reduced scattering material in the chamber gas and in the inner skin separating the drift chamber from the silicon vertex detector provides a reduction of the multiple scattering component of the momentum resolution and an extension of the usable measurement length into the silicon. Momentum resolution is further improved through quality control in wire positioning and symmetry of the electric fields in the drift cells which have provided a reduction in the spatial resolution to 88 mu m (averaged over the full drift range).

  3. Forecasting magma-chamber rupture at Santorini volcano, Greece.

    Science.gov (United States)

    Browning, John; Drymoni, Kyriaki; Gudmundsson, Agust

    2015-10-28

    How much magma needs to be added to a shallow magma chamber to cause rupture, dyke injection, and a potential eruption? Models that yield reliable answers to this question are needed in order to facilitate eruption forecasting. Development of a long-lived shallow magma chamber requires periodic influx of magmas from a parental body at depth. This redistribution process does not necessarily cause an eruption but produces a net volume change that can be measured geodetically by inversion techniques. Using continuum-mechanics and fracture-mechanics principles, we calculate the amount of magma contained at shallow depth beneath Santorini volcano, Greece. We demonstrate through structural analysis of dykes exposed within the Santorini caldera, previously published data on the volume of recent eruptions, and geodetic measurements of the 2011-2012 unrest period, that the measured 0.02% increase in volume of Santorini's shallow magma chamber was associated with magmatic excess pressure increase of around 1.1 MPa. This excess pressure was high enough to bring the chamber roof close to rupture and dyke injection. For volcanoes with known typical extrusion and intrusion (dyke) volumes, the new methodology presented here makes it possible to forecast the conditions for magma-chamber failure and dyke injection at any geodetically well-monitored volcano.

  4. Analysis of iris structure and iridocorneal angle parameters with anterior segment optical coherence tomography in Fuchs' uveitis syndrome.

    Science.gov (United States)

    Basarir, Berna; Altan, Cigdem; Pinarci, Eylem Yaman; Celik, Ugur; Satana, Banu; Demirok, Ahmet

    2013-06-01

    To evaluate the differences in the biometric parameters of iridocorneal angle and iris structure measured by anterior segment optical coherence tomography (AS-OCT) in Fuchs' uveitis syndrome (FUS). Seventy-six eyes of 38 consecutive patients with the diagnosis of unilateral FUS were recruited into this prospective, cross-sectional and comparative study. After a complete ocular examination, anterior segment biometric parameters were measured by Visante(®) AS-OCT. All parameters were compared between the two eyes of each patient statistically. The mean age of the 38 subjects was 32.5 ± 7.5 years (18 female and 20 male). The mean visual acuity was lower in eyes with FUS (0.55 ± 0.31) than in healthy eyes (0.93 ± 0.17). The central corneal thickness did not differ significantly between eyes. All iridocorneal angle parameters (angle-opening distance 500 and 750, scleral spur angle, trabecular-iris space (TISA) 500 and 750) except TISA 500 in temporal quadrant were significantly larger in eyes with FUS than in healthy eyes. Anterior chamber depth was deeper in the eyes with FUS than in the unaffected eyes. With regard to iris measurements, iris thickness in the thickest part, iris bowing and iris shape were all statistically different between the affected eye and the healthy eye in individual patients with FUS. However, no statistically significant differences were evident in iris thickness 500 μm, thickness in the middle and iris length. There were significant difference in iris shape between the two eyes of patients with glaucoma. AS-OCT as an imaging method provides us with many informative resultsin the analysis of anterior segment parameters in FUS.

  5. The high momentum spectrometer drift chambers

    Science.gov (United States)

    Abbott, D.; Baker, O. K.; Beaufait, J.; Bennett, C.; Bryant, E.; Carlini, R.; Kross, B.; McCauley, A.; Naing, W.; Shin, T.; Vulcan, W.

    1992-12-01

    The High Momentum Spectrometer in Hall C will use planar drift chambers for charged particle track reconstruction. The chambers are constructed using well understood technology and a conventional gas mixture. Two (plus one spare) drift chambers will be constructed for this spectrometers. Each chamber will contain 6 planes of readout channels. This paper describes the chamber design and gas handling system used.

  6. CLINICAL STUDY OF POSTERIOR CHAMBER PHAKIC IOL PLACEMENT IN MYOPIC PATIENTS

    Directory of Open Access Journals (Sweden)

    Ashok Kumar P

    2017-02-01

    Full Text Available BACKGROUND The aim of this study was to determine the safety and efficacy of posterior chamber phakic IOL in Myopic patients. MATERIALS AND METHODS This prospective interventional study included 50 eyes of 50 patients with myopia. Patients of age more than 18 yrs. Stable refraction, Myopia, Mild to Moderate keratoconus and absence of any ocular pathology and any history of ocular surgeries were included in this study. Prior to starting treatment certain parameters like visual acuity, AC depth, Iridocorneal Angle Aperture, Endothelial cell count, Central corneal thickness and IOP were considered. Intervention- Implantation of the phakic IOL. Main outcome Measures- Uncorrected Visual Acuity (UCVA, best spectacle corrected visual acuity (BSCVA, AS OCT AC depthbetween endothelium and phakic IOL, IOP and Endothelial cell count were recorded. RESULTS Postoperative examinations conducted at day 1, day 3, after 1 week, 1 month and after 3 months .out of 50 patients, 4 patients had striate keratopathy, 2 patients had shallow ac during immediate post-operative period. During the postoperative follow up 10 patients had BCVA of 6/9-6/6 (20%, 14 patients had 6/9-6/12 (28%, 24 patients had 6/12-6/24(48% and remaining 2 patients had <6/24 which was better than their preoperative uncorrected visual acuity. CONCLUSION Based on this prospective clinical study and on comparison with other clinical studies posterior chamber phakic IOL corrective procedures are safe and effective for treatment of myopia. It also shows that it can provide sharp and clear vision in 96% of our study population. It does not induce dry eye syndrome as in other refractive surgeries. Short term complications like endothelial damage, angle closure glaucoma, iritis, anterior capsule injury/lens changes were not encountered during our study. But still long term follow up is required to confirm long term safety of the implant.

  7. anterior hyaloidal fibrovascular proliferation

    African Journals Online (AJOL)

    Okonkwo

    It most commonly occurs after phakic vitrectomy and scleral buckling for diabetic traction retinal detachment. It usually manifests with haemorrhage into the vitreous cavity or anterior hyaloid 3 to 12 weeks after vitrectomy and is the result of fibrovascular proliferation from the peripheral retina extending toward the equator of ...

  8. Micro plate fission chamber development

    International Nuclear Information System (INIS)

    Wang Mei; Wen Zhongwei; Lin Jufang; Jiang Li; Liu Rong; Wang Dalun

    2014-01-01

    To conduct the measurement of neutron flux and the fission rate distribution at several position in assemblies, the micro plate fission chamber was designed and fabricated. Since the requirement of smaller volume and less structure material was taken into consideration, it is convinient, commercial and practical to use fission chamber to measure neutron flux in specific condition. In this paper, the structure of fission chamber and process of fabrication were introduced and performance test result was presented. The detection efficiency is 91.7%. (authors)

  9. Neutron detection via bubble chambers.

    Science.gov (United States)

    Jordan, D V; Ely, J H; Peurrung, A J; Bond, L J; Collar, J I; Flake, M; Knopf, M A; Pitts, W K; Shaver, M; Sonnenschein, A; Smart, J E; Todd, L C

    2005-01-01

    Research investigating the application of pressure-cycled bubble chambers to fast neutron detection is described. Experiments with a Halon-filled chamber showed clear sensitivity to an AmBe neutron source and insensitivity to a (137)Cs gamma source. Bubble formation was documented using high-speed photography, and a ceramic piezo-electric transducer element registered the acoustic signature of bubble formation. In a second set of experiments, the bubble nucleation response of a Freon-134a chamber to an AmBe neutron source was documented with high-speed photography.

  10. Neutron detection via bubble chambers

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, D.V. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States)]. E-mail: david.jordan@pnl.gov; Ely, J.H. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States); Peurrung, A.J. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States); Bond, L.J. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States); Collar, J.I. [Department of Physics and Enrico Fermi Institute, University of Chicago, 5640 S. Ellis Ave., LASR 214, Chicago, IL 60637 (United States); Flake, M. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States); Knopf, M.A. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States); Pitts, W.K. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States); Shaver, M. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States); Sonnenschein, A. [Department of Physics and Enrico Fermi Institute, University of Chicago, 5640 S. Ellis Ave., LASR 214, Chicago, IL 60637 (United States); Smart, J.E. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States); Todd, L.C. [Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States)

    2005-12-01

    Research investigating the application of pressure-cycled bubble chambers to fast neutron detection is described. Experiments with a Halon-filled chamber showed clear sensitivity to an AmBe neutron source and insensitivity to a {sup 137}Cs gamma source. Bubble formation was documented using high-speed photography, and a ceramic piezo-electric transducer element registered the acoustic signature of bubble formation. In a second set of experiments, the bubble nucleation response of a Freon-134a chamber to an AmBe neutron source was documented with high-speed photography.

  11. Pelletron general purpose scattering chamber

    International Nuclear Information System (INIS)

    Chatterjee, A.; Kailas, S.; Kerekette, S.S.; Navin, A.; Kumar, Suresh

    1993-01-01

    A medium sized stainless steel scattering chamber has been constructed for nuclear scattering and reaction experiments at the 14UD pelletron accelerator facility. It has been so designed that several types of detectors, varying from small sized silicon surface barrier detectors to medium sized gas detectors and NaI detectors can be conveniently positioned inside the chamber for detection of charged particles. The chamber has been planned to perform the following types of experiments : angular distributions of elastically scattered particles, fission fragments and other charged particles, angular correlations for charged particles e.g. protons, alphas and fission fragments. (author). 2 figs

  12. Toxic Anterior Segment Syndrome following a Triple Descemet’s Stripping Automated Endothelial Keratoplasty Procedure

    Directory of Open Access Journals (Sweden)

    Nir Sorkin

    2012-11-01

    Full Text Available Purpose: To present a unique case of a 58-year-old female with toxic anterior segment syndrome (TASS, following a triple procedure: Descemet’s stripping automated endothelial keratoplasty (DSAEK, phacoemulsification and posterior chamber intraocular lens implantation. Methods: The patient was treated with topical dexamethasone sodium phosphate 0.1% and topical atropine sulfate 1%. Due to a slow improvement in her clinical status, oral prednisone 1 mg/kg/day was added. Results: The anterior chamber reaction improved gradually, with tapering down of topical and oral treatment, until a complete resolution of the anterior chamber reaction was observed. Conclusions: Taking into account the estimated volume of DSAEK triple procedures performed worldwide, we would expect an annual incidence of several TASS cases, following triple DSAEK procedures. However, we were unable to find any such previous reports in the literature. This fact raises questions regarding the cause of reduced TASS incidence following triple DSAEK procedures.

  13. Rupture pressure of the posterior lamella obtained during big-bubble deep anterior lamellar keratoplasty.

    Science.gov (United States)

    McKee, Hamish D; Barua, Ankur; Brahma, Arun K; Jhanji, Vishal; Carley, Fiona M

    2012-11-01

    To investigate the pressure required to rupture the posterior lamella obtained during the presumed Descemet membrane-baring big-bubble technique of deep anterior lamellar keratoplasty (DALK). DALK using the big-bubble technique was carried out on donor corneoscleral discs mounted on an artificial anterior chamber. Once the anterior lamella was removed, the chamber was connected to a mercury manometer. The pressure inside the chamber was increased until rupture occurred or the manometer reached its measurement limit. The deep lamella ruptured at 252 mm Hg in one cornea, at 270 mm Hg in another, and had not ruptured at 300 mm Hg (upper limit of the manometer) in the remaining 18 donor corneas. The posterior lamella of big-bubble DALK probably confers significant structural integrity on the globe.

  14. Changes in choroidal thickness after prophylactic iridectomy in primary angle closure suspect eyes using enhanced depth imaging optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2015-01-01

    Full Text Available Purpose: The aim of the present study was to evaluate the effect of surgical peripheral iridectomy (SPI on choroidal thickness in primary angle-closure suspect (PACS eyes. Materials and Methods: This was a prospective observational case series of 30 subjects with PACS. Ocular biometry was performed before SPI (baseline and then 1 week later. Choroid was imaged by enhanced depth imaging optical coherence tomography (EDI-OCT. The choroidal thickness of the subfoveal area at 1 and 3 mm diameter around the fovea was determined. Central anterior chamber depth (ACD, lens thickness (LT, vitreous chamber depth (VCD, and axial length (AL were measured by A-scan ultrasound. Parameters were compared before SPI (baseline and 1 week later. Results: Thirty eyes of 30 patients with mean age of 61.53 ± 7.98 years were studied. There was no significant difference in the choroidal thickness at all macular locations before and after SPI (all P > 0.05. Mean subfoveal choroidal thickness was 279.61 μm ± 65.50 μm before and 274.54 μm ± 63.36 μm after SPI (P = 0.308. There was also no significant change in central ACD, LT, VCD, and LT after SPI (all P > 0.05. Conclusions: SPI does not appear to alter choroidal thickness in PACS eyes, as assessed using EDI-OCT. Long-term follow-up of PACS eyes treated with SPI may provide further insight into the effects of this treatment modality on the choroid.

  15. The multigap resistive plate chamber

    Energy Technology Data Exchange (ETDEWEB)

    Zeballos, E. Cerron [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Crotty, I. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Hatzifotiadou, D. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Valverde, J. Lamas [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Univ. Louis Pasteur, Strasbourg (France); Neupane, S. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); World Lab., Lausanne (Switzerland); Williams, M. C. S. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Zichichi, A. [Univ. of Bologna, Bologna (Italy)

    2015-02-03

    The paper describes the multigap resistive plate chamber (RPC). This is a variant of the wide gap RPC. However it has much improved time resolution, while keeping all the other advantages of the wide gap RPC design.

  16. Study of energy dependence of a extrapolation chamber in low energy X-rays beams

    International Nuclear Information System (INIS)

    Bastos, Fernanda M.; Silva, Teogenes A. da

    2014-01-01

    This work was with the main objective to study the energy dependence of extrapolation chamber in low energy X-rays to determine the value of the uncertainty associated with the variation of the incident radiation energy in the measures in which it is used. For studying the dependence of energy, were conducted comparative ionization current measurements between the extrapolation chamber and two ionization chambers: a chamber mammography, RC6M model, Radcal with energy dependence less than 5% and a 2575 model radioprotection chamber NE Technology; both chambers have very thin windows, allowing its application in low power beams. Measurements were made at four different depths of 1.0 to 4.0 mm extrapolation chamber, 1.0 mm interval, for each reference radiation. The study showed that there is a variable energy dependence on the volume of the extrapolation chamber. In other analysis, it is concluded that the energy dependence of extrapolation chamber becomes smaller when using the slope of the ionization current versus depth for the different radiation reference; this shows that the extrapolation technique, used for the absorbed dose calculation, reduces the uncertainty associated with the influence of the response variation with energy radiation

  17. Light diffusing fiber optic chamber

    Science.gov (United States)

    Maitland, Duncan J.

    2002-01-01

    A light diffusion system for transmitting light to a target area. The light is transmitted in a direction from a proximal end to a distal end by an optical fiber. A diffusing chamber is operatively connected to the optical fiber for transmitting the light from the proximal end to the distal end and transmitting said light to said target area. A plug is operatively connected to the diffusing chamber for increasing the light that is transmitted to the target area.

  18. Advances on fission chamber modelling

    International Nuclear Information System (INIS)

    Filliatre, Philippe; Jammes, Christian; Geslot, Benoit; Veenhof, Rob

    2013-06-01

    In-vessel, online neutron flux measurements are routinely performed in mock-up and material testing reactors by fission chambers. Those measurements have a wide range of applications, including characterization of experimental conditions, reactor monitoring and safety. Depending on the application, detectors may experience a wide range of constraints, of several magnitudes, in term of neutron flux, gamma-ray flux, temperature. Hence, designing a specific fission chamber and measuring chain for a given application is a demanding task. It can be achieved by a combination of experimental feedback and simulating tools, the latter being based on a comprehensive understanding of the underlying physics. A computation route that simulates fission chambers, named CHESTER, is presented. The retrieved quantities of interest are the neutron-induced charge spectrum, the electronic and ionic pulses, the mean current and variance, the power spectrum. It relies on the GARFIELD suite, originally developed for drift chambers, and makes use of the MAGBOLTZ code to assess the drift parameters of electrons within the filling gas, and the SRIM code to evaluate the stopping range of fission products. The effect of the gamma flux is also estimated. Computations made with several fission chambers exemplify the possibilities of the route. A good qualitative agreement is obtained when comparing the results with the experimental data available to date. In a near future, a comprehensive experimental programme will be undertaken to qualify the route using the known neutron sources, mock-up reactors and wide choice of fission chambers, with a stress on the predictiveness of the Campbelling mode. Depending on the results, a refinement of the modelling and an effort on the accuracy of input data are also to be considered. CHESTER will then make it possible to predict the overall sensitivity of a chamber, and to optimize the design for a given application. Another benefit will be to increase the

  19. Proton beam monitor chamber calibration

    International Nuclear Information System (INIS)

    Gomà, C; Meer, D; Safai, S; Lorentini, S

    2014-01-01

    The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic proton beam. For the latter, this paper also compares two independent dosimetry techniques to calibrate the beam monitor chambers: absolute dosimetry (of the number of protons exiting the nozzle) with a Faraday cup and reference dosimetry (i.e. determination of the absorbed dose to water under IAEA TRS-398 reference conditions) with an ionization chamber. To compare the two techniques, Monte Carlo simulations were performed to convert dose-to-water to proton fluence. A good agreement was found between the Faraday cup technique and the reference dosimetry with a plane-parallel ionization chamber. The differences—of the order of 3%—were found to be within the uncertainty of the comparison. For cylindrical ionization chambers, however, the agreement was only possible when positioning the effective point of measurement of the chamber at the reference measurement depth—i.e. not complying with IAEA TRS-398 recommendations. In conclusion, for cylindrical ionization chambers, IAEA TRS-398 reference conditions for monoenergetic proton beams led to a systematic error in the determination of the absorbed dose to water, especially relevant for low-energy proton beams. To overcome this problem, the effective point of measurement of cylindrical ionization chambers should be taken into account when positioning the reference point of the chamber. Within the current IAEA TRS-398 recommendations, it seems advisable to use plane-parallel ionization chambers—rather than cylindrical chambers—for the reference dosimetry of pseudo-monoenergetic proton beams. (paper)

  20. BEBC Big European Bubble Chamber

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    A view of the dismantling of the magnet of BEBC, the 3.7 m European Bubble Chamber : iron magnetic shielding ; lower and upper parts of the vacuum enclosure of the magnet; turbo-molecular vacuum pumps for the "fish-eye" windows; the two superconducting coils; a handling platform; the two cryostats suspended from the bar of the travelling crane which has a 170 ton carrying capacity. The chamber proper, not dismantled, is inside the shielding.

  1. Anterior cruciate ligament repair - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100230.htm Anterior cruciate ligament repair - Series—Normal anatomy To use the sharing ... to slide 5 out of 5 Overview The anterior cruciate ligament (ACL) is a ligament in the center of ...

  2. Multidisciplinary management of anterior diastemata

    DEFF Research Database (Denmark)

    Furuse, Adilson Yoshio; Herkrath, Fernando José; Franco, Eduardo Jacomino

    2007-01-01

    Anterior diastemata may compromise the harmony of a patient's smile. Consideration of etiologic factors, previous gingival conditioning, and individual treatment planning are essential in the proper management of anterior diastemata. An integrated orthodontic-restorative approach may enhance...

  3. Comparison of anterior segment measurements using Sirius Topographer® and Nidek Axial Length-Scan® with assessing repeatability in patients with cataracts

    Directory of Open Access Journals (Sweden)

    Resat Duman

    2018-01-01

    Full Text Available Purpose: The purpose of this study is to evaluate anterior segment measurements obtained using CSO Sirius Topographer® (CSO, Firenze, Italy and Nidek Axial Length (AL-Scan® (Nidek CO., Gamagori, Japan. Methods: A total of 43 eyes of 43 patients were included in this prospective study. The central corneal thickness (CCT, anterior chamber depth (ACD, white-to-white distance (WTW, flat keratometry (K1, steep keratometry (K2, and mean keratometry (K values were randomly measured three times with each device by the same examiner. The intraclass correlation coefficient of repeatability was analyzed. The compatibility of both devices was evaluated using the 95% limits of the agreement proposed by Bland and Altman. Results: Examiner achieved high repeatability for all parameters on each device except the WTW measured by Sirius. All measurements except WTW and K1 taken with the Sirius were higher than that taken with the Nidek AL-Scan®. The difference in CCT, ACD, and WTW values was statistically significant. Conclusion: High repeatability of the measurements was achieved on both devices. Although Km, K1, and K2 measurements of the Sirius and the AL-Scan® showed good agreement, WTW, CCT, and ACD measurements significantly differed between two devices. Thus, anterior segment measurements except for Km, K1, and K2 cannot be used interchangeably between Sirius and Nidek AL-Scan® devices.

  4. Implantation of scleral fixated sutured posterior chamber lenses: a retrospective analysis of 119 cases.

    Science.gov (United States)

    Krause, Lothar; Bechrakis, Nikolaos E; Heimann, Heinrich; Salditt, Stefan; Foerster, Michael H

    2009-08-01

    The implantation of scleral fixated sutured posterior chamber lenses enables lens implantation in the absence of adequate lens capsule support. Anterior chamber lenses and their side effects can also be avoided, particularly in cases of unilateral aphakia and contact lens incompatibility. This study is a retrospective analysis of 119 scleral fixated sutured posterior chamber lenses implanted in 115 patients. Seventy-nine cases of damaged zonula or damaged lens capsule and 17 cases of corneal decompensation secondary to anterior chamber lenses were the main indications for the suture fixation. The mean follow-up was 23 months (6-83 months). In 50% of all cases, improved visual acuity was achieved. Twenty-four percent of patients showed unchanged visual acuity, while 26% had poorer vision postoperatively, mainly because of corneal decompensation following anterior chamber lens explantation. The main postoperative complication was transient rise of intraocular pressure, occurring in 44% of the cases. In most cases improved or comparable postoperative visual acuity was achieved. The main complication observed was postoperative glaucoma, especially in patients with pre-existing glaucoma.

  5. Motivation with Depth.

    Science.gov (United States)

    DiSpezio, Michael A.

    2000-01-01

    Presents an illusional arena by offering experience in optical illusions in which students must apply critical analysis to their innate information gathering systems. Introduces different types of depth illusions for students to experience. (ASK)

  6. Capsular phimosis with complete occlusion of the anterior capsular opening after intact continuous curvilinear capsulorrhexis

    International Nuclear Information System (INIS)

    AlKharashi, Soliman A

    2009-01-01

    Shrinkage and whitening of the anterior capsule opening - capsular contraction syndrome - is a well-known complication after continuous curvilinear capsulorrhexis. A 72-year-old women underwent continuous curvilinear capsulorrhexis, phacoemulsification, and implantation of posterior chamber intraocular lens with polymethylmethacrylate haptics. Four months postoperatively, the patient reported deterioration in visual acuity that was resulted due to complete occlusion of anterior capsular opening by fibrotic tissue. The fibrous membrane was excised surgically in capsulorrhexis fashion. (author)

  7. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  8. Directional muon jet chamber for a muon collider (Groovy Chamber)

    International Nuclear Information System (INIS)

    Atac, M.

    1996-10-01

    A directional jet drift chamber with PAD readout is proposed here which can select vertex originated muons within a given time window and eliminate those muons which primarily originate upstream, using only a PAD readout. Drift time provides the Z-coordinate, and the center of gravity of charge distribution provides the r-ψ coordinates. Directionality at the trigger level is obtained by the timing measurement from the PAD hits within a given time window. Because of the long drift time between the bunch crossings, a muon collider enables one to choose a drift distance in the drift chamber as long as 50 cm. This is an important factor in reducing cost of drift chambers which have to cover relatively large areas

  9. Morphometric changes of corneal endothelial cells following intracameral air for micro perforation of the Descemet Membrane during big-bubble deep anterior lamellar keratoplasty

    Directory of Open Access Journals (Sweden)

    Ashbala Khattak

    2016-04-01

    Conclusion: The presence of air inside the anterior chamber for a short term may not cause further endothelial cell loss and can be safely performed to prevent postoperative Descemet Membrane detachment in case of micro perforations.

  10. Plasma chemistry in wire chambers

    International Nuclear Information System (INIS)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an 55 Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed

  11. Neutron Detection via Bubble Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, David V.; Ely, James H.; Peurrung, Anthony J.; Bond, Leonard J.; Collar, J. I.; Flake, Matthew; Knopf, Michael A.; Pitts, W. K.; Shaver, Mark W.; Sonnenschein, Andrew; Smart, John E.; Todd, Lindsay C.

    2005-10-06

    The results of a Pacific Northwest National Laboratory (PNNL) exploratory research project investigating the feasibility of fast neutron detection using a suitably prepared and operated, pressure-cycled bubble chamber are described. The research was conducted along two parallel paths. Experiments with a slow pressure-release Halon chamber at the Enrico Fermi Institute at the University of Chicago showed clear bubble nucleation sensitivity to an AmBe neutron source and insensitivity to the 662 keV gammas from a 137Cs source. Bubble formation was documented via high-speed (1000 frames/sec) photography, and the acoustic signature of bubble formation was detected using a piezo-electric transducer element mounted on the base of the chamber. The chamber’s neutron sensitivity as a function of working fluid temperature was mapped out. The second research path consisted of the design, fabrication, and testing of a fast pressure-release Freon-134a chamber at PNNL. The project concluded with successful demonstrations of the PNNL chamber’s AmBe neutron source sensitivity and 137Cs gamma insensitivity. The source response tests of the PNNL chamber were documented with high-speed photography.

  12. Bluetooth Communication Interface for EEG Signal Recording in Hyperbaric Chambers.

    Science.gov (United States)

    Pastena, Lucio; Formaggio, Emanuela; Faralli, Fabio; Melucci, Massimo; Rossi, Marco; Gagliardi, Riccardo; Ricciardi, Lucio; Storti, Silvia F

    2015-07-01

    Recording biological signals inside a hyperbaric chamber poses technical challenges (the steel walls enclosing it greatly attenuate or completely block the signals as in a Faraday cage), practical (lengthy cables creating eddy currents), and safety (sparks hazard from power supply to the electronic apparatus inside the chamber) which can be overcome with new wireless technologies. In this technical report we present the design and implementation of a Bluetooth system for electroencephalographic (EEG) recording inside a hyperbaric chamber and describe the feasibility of EEG signal transmission outside the chamber. Differently from older systems, this technology allows the online recording of amplified signals, without interference from eddy currents. In an application of this technology, we measured EEG activity in professional divers under three experimental conditions in a hyperbaric chamber to determine how oxygen, assumed at a constant hyperbaric pressure of 2.8 ATA , affects the bioelectrical activity. The EEG spectral power estimated by fast Fourier transform and the cortical sources of the EEG rhythms estimated by low-resolution brain electromagnetic analysis were analyzed in three different EEG acquisitions: breathing air at sea level; breathing oxygen at a simulated depth of 18 msw, and breathing air at sea level after decompression.

  13. Perawatan Ortodontik Gigitan Terbuka Anterior

    Directory of Open Access Journals (Sweden)

    Yuniar Zen

    2014-06-01

    Full Text Available Perawatan gigitan terbuka anterior telah lama dianggap sebagai tantangan bagi ortodontis. Prevalensi gigitan terbuka anterior antara 3,5% hingga 11% terdapat pada berbagai usia dan kelompok etnis, serta ada sekitar 17% pasien ortodonti memiliki gigitan terbuka. Stabilitas hasil perawatan gigitan terbuka anterior sangat sulit, karena adanya kombinasi diskrepansi anteroposterior dengan gigitan terbuka skeletal sehingga dibutuhkan tingkat keterampilan diagnosis dan klinis yang tinggi. Etiologi gigitan terbuka anterior sangat kompleks karena dapat melibatkan skeletal, dental, dan faktor-faktor habitual. Eliminasi faktor etiologi merupakan hal yang penting dalam perawatan gigitan terbuka anterior. Berbagai cara perawatan untuk koreksi gigitan terbuka anterior diantaranya bedah ortognatik dan perawatan ortodontik kamuflase, seperti high-pull headgear, chincup, bite blocks, alatfungsional, pencabutan gigi, multi-loop edgewise archwires dan mini implan. Stabilitas hasil perawatan adalah kriteria yang paling penting dalam menentukan cara perawatan gigitan terbuka anterior. Orthodontic Treatment of Anterior Open Bite. An anterior open bite therapy has long been considered a challenge to orthodontist. The prevalence of anterior openbite range from 3,5 % to 11% among various age and ethnic groups and it has been shown that approximately 17% of orthodontic patients have open bite. Stability of treatment result of anterior open bite with well-maintained results is difficult, because the combination of anteroposteriorly discrepancy with skeletal open bite requires the highest degree of diagnostic and clinical skill. The etiology is complex, potentially involving skeletal, dental and habitual factors. The importance of an anterior open bite therapy is to eliminate the cause of the open bite. Various treatment modalities for the correction of an anterior open bite have been proposed, orthognatic surgery and orthodontic camouflage treatment such as high

  14. Production depths increasing

    Energy Technology Data Exchange (ETDEWEB)

    Dufond, R.

    1984-05-01

    Much research and development has been concentrated on the feasibility, testing and economics of oil production systems in 1000-2000 ft of water, with a possible extrapolation to 3000 ft. The deepest water production facilities are those of Shell Oil's Cognac platform in the Gulf of Mexico, at a depth of 1050 ft of water. The record drilling depth is 6448 ft off New Jersey, but several French firms are preparing equipment and procedures for drilling a well in 10,000 ft of water in the Mediterranean Sea.

  15. Evaluation of functioning of an extrapolation chamber using Monte Carlo method

    International Nuclear Information System (INIS)

    Oramas Polo, I.; Alfonso Laguardia, R.

    2015-01-01

    The extrapolation chamber is a parallel plate chamber and variable volume based on the Braff-Gray theory. It determines in absolute mode, with high accuracy the dose absorbed by the extrapolation of the ionization current measured for a null distance between the electrodes. This camera is used for dosimetry of external beta rays for radiation protection. This paper presents a simulation for evaluating the functioning of an extrapolation chamber type 23392 of PTW, using the MCNPX Monte Carlo method. In the simulation, the fluence in the air collector cavity of the chamber was obtained. The influence of the materials that compose the camera on its response against beta radiation beam was also analysed. A comparison of the contribution of primary and secondary radiation was performed. The energy deposition in the air collector cavity for different depths was calculated. The component with the higher energy deposition is the Polymethyl methacrylate block. The energy deposition in the air collector cavity for chamber depth 2500 μm is greater with a value of 9.708E-07 MeV. The fluence in the air collector cavity decreases with depth. It's value is 1.758E-04 1/cm 2 for chamber depth 500 μm. The values reported are for individual electron and photon histories. The graphics of simulated parameters are presented in the paper. (Author)

  16. The CLAS drift chamber system

    CERN Document Server

    Mestayer, M D; Asavapibhop, B; Barbosa, F J; Bonneau, P; Christo, S B; Dodge, G E; Dooling, T; Duncan, W S; Dytman, S A; Feuerbach, R; Gilfoyle, G P; Gyurjyan, V; Hicks, K H; Hicks, R S; Hyde-Wright, C E; Jacobs, G; Klein, A; Klein, F J; Kossov, M; Kuhn, S E; Magahiz, R A; Major, R W; Martin, C; McGuckin, T; McNabb, J; Miskimen, R A; Müller, J A; Niczyporuk, B B; O'Meara, J E; Qin, L M; Raue, B A; Robb, J; Roudot, F; Schumacher, R A; Tedeschi, D J; Thompson, R A; Tilles, D; Tuzel, W; Vansyoc, K; Vineyard, M F; Weinstein, L B; Wilkin, G R; Yegneswaran, A; Yun, J

    2000-01-01

    Experimental Hall B at Jefferson Laboratory houses the CEBAF Large Acceptance Spectrometer, the magnetic field of which is produced by a superconducting toroid. The six coils of this toroid divide the detector azimuthally into six sectors, each of which contains three large multi-layer drift chambers for tracking charged particles produced from a fixed target on the toroidal axis. Within the 18 drift chambers are a total of 35,148 individually instrumented hexagonal drift cells. The novel geometry of these chambers provides for good tracking resolution and efficiency, along with large acceptance. The design and construction challenges posed by these large-scale detectors are described, and detailed results are presented from in-beam measurements.

  17. "Flat-Fish" Vacuum Chamber

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    The picture shows a "Flat-Fish" vacuum chamber being prepared in the ISR workshop for testing prior to installation in the Split Field Magnet (SFM) at intersection I4. The two shells of each part were hydroformed from 0.15 mm thick inconel 718 sheet (with end parts in inconel 600 for easier manual welding to the arms) and welded toghether with two strips which were attached by means of thin stainless steel sheets to the Split Field Magnet poles in order to take the vertical component of the atmospheric pressure force. This was the thinnest vacuum chamber ever made for the ISR. Inconel material was chosen for its high elastic modulus and strenght at chamber bake-out temperature. In this picture the thin sheets transferring the vertical component of the atmosferic pressure force are attached to a support frame for testing. See also 7712182, 7712179.

  18. Holography in small bubble chambers

    International Nuclear Information System (INIS)

    Lecoq, P.

    1984-01-01

    This chapter reports on an experiment to determine the total charm cross section at different incident momenta using the small, heavy liquid bubble chamber HOBC. Holography in liquid hydrogen is also tested using the holographic lexan bubble chamber HOLEBC with the aim of preparing a future holographic experiment in hydrogen. The high intensity tests show that more than 100 incident tracks per hologram do not cause a dramatic effect on the picture quality. Hydrogen is more favorable than freon as the bubble growth is much slower in hydrogen. An advantage of holography is to have the maximum resolution in the full volume of the bubble chamber, which allows a gain in sensitivity by a factor of 10 compared to classical optics as 100 tracks per hologram look reasonable. Holograms are not more difficult to analyze than classical optics high-resolution pictures. The results show that holography is a very powerful technique which can be used in very high resolution particle physics experiments

  19. Anterior knee pain

    Energy Technology Data Exchange (ETDEWEB)

    LLopis, Eva [Hospital de la Ribera, Alzira, Valencia (Spain) and Carretera de Corbera km 1, 46600 Alzira Valencia (Spain)]. E-mail: ellopis@hospital-ribera.com; Padron, Mario [Clinica Cemtro, Ventisquero de la Condesa no. 42, 28035 Madrid (Spain)]. E-mail: mario.padron@clinicacemtro.com

    2007-04-15

    Anterior knee pain is a common complain in all ages athletes. It may be caused by a large variety of injuries. There is a continuum of diagnoses and most of the disorders are closely related. Repeated minor trauma and overuse play an important role for the development of lesions in Hoffa's pad, extensor mechanism, lateral and medial restrain structures or cartilage surface, however usually an increase or change of activity is referred. Although the direct relation of cartilage lesions, especially chondral, and pain is a subject of debate these lesions may be responsible of early osteoarthrosis and can determine athlete's prognosis. The anatomy and biomechanics of patellofemoral joint is complex and symptoms are often unspecific. Transient patellar dislocation has MR distinct features that provide evidence of prior dislocation and rules our complication. However, anterior knee pain more often is related to overuse and repeated minor trauma. Patella and quadriceps tendon have been also implicated in anterior knee pain, as well as lateral or medial restraint structures and Hoffa's pad. US and MR are excellent tools for the diagnosis of superficial tendons, the advantage of MR is that permits to rule out other sources of intraarticular derangements. Due to the complex anatomy and biomechanic of patellofemoral joint maltracking is not fully understood; plain films and CT allow the study of malalignment, new CT and MR kinematic studies have promising results but further studies are needed. Our purpose here is to describe how imaging techniques can be helpful in precisely defining the origin of the patient's complaint and thus improve understanding and management of these injuries.

  20. Complications and Management of Deep Anterior Lamellar Keratoplasty

    Directory of Open Access Journals (Sweden)

    Banu Torun Acar

    2014-10-01

    Full Text Available Objectives: To report the intraoperative and postoperative follow-up complications and management of these in deep anterior lamellar keratoplasty (DALK surgery. Materials and Methods: Two hundred eighty-four eyes of 252 patients followed up in our cornea clinic who underwent DALK using Anwar’s big-bubble technique with healthy Descemet’s membrane and endothelium were included in this study. Intraoperative and postoperative complications as well as the management and treatment of these complications were evaluated. Results: Big bubble was created in 220 (77.5% eyes of 284 eyes, and lamellar dissection was performed in 64 (22.5% eyes. Perforation occurred during trephination in 4 eyes, and the procedure was accomplished by penetrating keratoplasty (PK. Intraoperative microperforation occurred in 44 eyes. Perforation enlarged in 4 eyes and PK was performed. Operation was continued in 40 eyes with air injection into the anterior chamber. In postopertive follow-up period, double anterior chamber (DAC occurred in 32 of 40 eyes. DAC spontaneously regressed in 8 eyes, and air was given into the anterior chamber with a second surgical intervention in 24 eyes. DAC improved in 20 eyes. Four eyes underwent PK. Fungal keratitis evolved at the interface in one eye, because of no healing during the follow-up period, this eye underwent PK under antifungal therapy. Eyes with interface haze and Descemet’s membrane folds were followed. Conclusion: DALK is a difficult technique with a steep learning curve. In addition to the complications seen in PK, specific complications can occur in lamellar surgery. (Turk J Ophthalmol 2014; 44: 337-40

  1. Evaluating anterior knee pain.

    Science.gov (United States)

    Hong, Engene; Kraft, Michael C

    2014-07-01

    Musculoskeletal complaints account for about 20% to 30% of all primary care office visits; of these visits, discomfort in the knee, shoulder, and back are the most prevalent musculoskeletal symptoms. Having pain or dysfunction in the front part of the knee is a common presentation and reason for a patient to see a health care provider. There are a number of pathophysiological etiologies to anterior knee pain. This article describes some of the common and less common causes, and includes sections on diagnosis and treatment for each condition as well as key points. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. The anterior cingulate cortex

    Directory of Open Access Journals (Sweden)

    Pavlović D.M.

    2009-01-01

    Full Text Available The anterior cingulate cortex (ACC has a role in attention, analysis of sensory information, error recognition, problem solving, detection of novelty, behavior, emotions, social relations, cognitive control, and regulation of visceral functions. This area is active whenever the individual feels some emotions, solves a problem, or analyzes the pros and cons of an action (if it is a right decision. Analogous areas are also found in higher mammals, especially whales, and they contain spindle neurons that enable complex social interactions. Disturbance of ACC activity is found in dementias, schizophrenia, depression, the obsessive-compulsive syndrome, and other neuropsychiatric diseases.

  3. Ionization chambers for LET determination

    DEFF Research Database (Denmark)

    Kaiser, Franz-Joachim; Bassler, Niels; Tölli, Heikki

    2010-01-01

    resolution and high sensitivity are necessary. For exact dosimetry which is done using ionization chambers (ICs), the recombination taking place in the IC has to be known. Up to now, recombination is corrected phenomenologically and more practical approaches are currently used. Nevertheless, Jaff´e's theory...... of columnar recombination was designed to model the detector efficiency of an ionization chamber. Here, we have shown that despite the approximations and simplification made, the theory is correct for the LETs typically found in clinical radiotherapy employing particles from protons to carbon ions...

  4. Laboratory Course on Drift Chambers

    International Nuclear Information System (INIS)

    Garcia-Ferreira, Ix-B.; Garcia-Herrera, J.; Villasenor, L.

    2006-01-01

    Drift chambers play an important role in particle physics experiments as tracking detectors. We started this laboratory course with a brief review of the theoretical background and then moved on to the the experimental setup which consisted of a single-sided, single-cell drift chamber. We also used a plastic scintillator paddle, standard P-10 gas mixture (90% Ar, 10% CH4) and a collimated 90Sr source. During the laboratory session the students performend measurements of the following quantities: a) drift velocities and their variations as function of the drift field; b) gas gains and c) diffusion of electrons as they drifted in the gas

  5. Evaluation of ion chamber dependent correction factors for ionisation chamber dosimetry in proton beams using a Monte Carlo method

    International Nuclear Information System (INIS)

    Palmans, H.; Verhaegen, F.

    1995-01-01

    In the last decade, several clinical proton beam therapy facilities have been developed. To satisfy the demand for uniformity in clinical (routine) proton beam dosimetry two dosimetry protocols (ECHED and AAPM) have been published. Both protocols neglect the influence of ion chamber dependent parameters on dose determination in proton beams because of the scatter properties of these beams, although the problem has not been studied thoroughly yet. A comparison between water calorimetry and ionisation chamber dosimetry showed a discrepancy of 2.6% between the former method and ionometry following the ECHED protocol. Possibly, a small part of this difference can be attributed to chamber dependent correction factors. Indications for this possibility are found in ionometry measurements. To allow the simulation of complex geometries with different media necessary for the study of those corrections, an existing proton Monte Carlo code (PTRAN, Berger) has been modified. The original code, that applies Mollire's multiple scattering theory and Vavilov's energy straggling theory, calculates depth dose profiles, energy distributions and radial distributions for pencil beams in water. Comparisons with measurements and calculations reported in the literature are done to test the program's accuracy. Preliminary results of the influence of chamber design and chamber materials on dose to water determination are presented

  6. Evaluation of ion chamber dependent correction factors for ionisation chamber dosimetry in proton beams using a Monte Carlo method

    Energy Technology Data Exchange (ETDEWEB)

    Palmans, H. [Ghent Univ. (Belgium). Dept. of Biomedical Physics; Verhaegen, F.

    1995-12-01

    In the last decade, several clinical proton beam therapy facilities have been developed. To satisfy the demand for uniformity in clinical (routine) proton beam dosimetry two dosimetry protocols (ECHED and AAPM) have been published. Both protocols neglect the influence of ion chamber dependent parameters on dose determination in proton beams because of the scatter properties of these beams, although the problem has not been studied thoroughly yet. A comparison between water calorimetry and ionisation chamber dosimetry showed a discrepancy of 2.6% between the former method and ionometry following the ECHED protocol. Possibly, a small part of this difference can be attributed to chamber dependent correction factors. Indications for this possibility are found in ionometry measurements. To allow the simulation of complex geometries with different media necessary for the study of those corrections, an existing proton Monte Carlo code (PTRAN, Berger) has been modified. The original code, that applies Mollire`s multiple scattering theory and Vavilov`s energy straggling theory, calculates depth dose profiles, energy distributions and radial distributions for pencil beams in water. Comparisons with measurements and calculations reported in the literature are done to test the program`s accuracy. Preliminary results of the influence of chamber design and chamber materials on dose to water determination are presented.

  7. [Zebrafish-a new animal models of anterior segment embryonic development and diseases basic research].

    Science.gov (United States)

    Hao, Yong-na; Wei, Rui-hua; Zhao, Shao-zhen

    2012-01-01

    In recent years, zebrafish has become ideal animal models of human disease with its unique characteristics, such as small body, fecundity, fast development and growth, embryo transparency, and so on. Furthermore, the structure and gene of zebrafish eye are highly conservative with human eye, which make ophthalmologists to pay close attention to zebrafish. This review focus on the studies and applications on zebrafish embryonic development of anterior segment, including the morphogenesis of cornea, lens and anterior chamber, and diseases of anterior segment (corneal diseases, cataract, glaucoma).

  8. Modeled Daily Thaw Depth and Frozen Ground Depth, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains modeled daily thaw depth and freezing depth for the Arctic terrestrial drainage basin. Thaw and freezing depths were calculated over the study...

  9. Sexual dimorphism of the internal mandibular chamber in Fayum Pliohyracidae (Mammalia)

    Science.gov (United States)

    de Blieux, D.D.; Baumrind, M.R.; Simons, E.L.; Chatrath, P.S.; Meyer, G.E.; Attia, Y.S.

    2006-01-01

    An internal mandibular fenestra and chamber are found in many fossil hyracoids. The internal mandibular fenestra is located on the lingual surface of the mandibular corpus and opens into a chamber within the mandible. The mandibular chamber is maximally developed in late Eocene Thyrohyrax meyeri and early Oligocene Thyrohyrax domorictus from the Fayum Province of Egypt. The function of this chamber is unknown as it is not found in extant hyraxes, nor is it known to occur in any other mammal. In Thyrohyrax, this feature appears to be sexually dimorphic because it is confined to roughly one half of the specimens that otherwise cannot be separated by dental characteristics or measurements. It has been suggested that the chamber is found in females based on the presumed distribution of this character in other fossil hyracoids. Fossils from Fayum Quarry L-41, preserving the sexually dimorphic anterior dentition, show that, in Thyrohyrax meyeri and Thyrohyrax domorictus, the internal mandibular chamber is found in males. In Thyrohyrax litholagus, an internal mandibular fenestra and inflated mandibular chamber occurs in males whereas females show the variable presence of an internal mandibular fossa or fenestra but lack an expanded chamber. Other genera show differing patterns of sexual variation in which some Fayum hyracoids have an internal mandibular fenestra in both sexes but with the greatest development of the mandibular chamber occurring in males. We review functions proposed for the internal mandibular chamber and suggest that it housed a laryngeal air sac that may have had a vocal function by acting as a resonating chamber. ?? 2006 by the Society of Vertebrate Paleontology.

  10. Why bother about depth?

    DEFF Research Database (Denmark)

    Stæhr, Peter A.; Obrador, Biel; Christensen, Jesper Philip

    We present results from a newly developed method to determine depth specific rates of GPP, NEP and R using frequent automated profiles of DO and temperature. Metabolic rate calculations were made for three lakes of different trophic status using a diel DO methodology that integrates rates across...

  11. Defining depth of anesthesia.

    Science.gov (United States)

    Shafer, S L; Stanski, D R

    2008-01-01

    In this chapter, drawn largely from the synthesis of material that we first presented in the sixth edition of Miller's Anesthesia, Chap 31 (Stanski and Shafer 2005; used by permission of the publisher), we have defined anesthetic depth as the probability of non-response to stimulation, calibrated against the strength of the stimulus, the difficulty of suppressing the response, and the drug-induced probability of non-responsiveness at defined effect site concentrations. This definition requires measurement of multiple different stimuli and responses at well-defined drug concentrations. There is no one stimulus and response measurement that will capture depth of anesthesia in a clinically or scientifically meaningful manner. The "clinical art" of anesthesia requires calibration of these observations of stimuli and responses (verbal responses, movement, tachycardia) against the dose and concentration of anesthetic drugs used to reduce the probability of response, constantly adjusting the administered dose to achieve the desired anesthetic depth. In our definition of "depth of anesthesia" we define the need for two components to create the anesthetic state: hypnosis created with drugs such as propofol or the inhalational anesthetics and analgesia created with the opioids or nitrous oxide. We demonstrate the scientific evidence that profound degrees of hypnosis in the absence of analgesia will not prevent the hemodynamic responses to profoundly noxious stimuli. Also, profound degrees of analgesia do not guarantee unconsciousness. However, the combination of hypnosis and analgesia suppresses hemodynamic response to noxious stimuli and guarantees unconsciousness.

  12. Toxic anterior-segment syndrome (TASS

    Directory of Open Access Journals (Sweden)

    Cetinkaya S

    2014-10-01

    Full Text Available Servet Cetinkaya,1 Zeynep Dadaci,2 Hüsamettin Aksoy,3 Nursen Oncel Acir,2 Halil Ibrahim Yener,4 Ekrem Kadioglu5 1Ophthalmology Clinics, Turkish Red Crescent Hospital, Konya, 2Department of Ophthalmology, Faculty of Medicine, Mevlana University, Konya, 3Ophthalmology Clinics, Karaman State Hospital, Karaman, 4Konya Eye Center Hospital, Konya, 5Ophthalmology Clinics, Beyhekim State Hospital, Konya, Turkey Purpose: To evaluate the clinical findings and courses of five patients who developed toxic anterior-segment syndrome (TASS after cataract surgery and investigate the cause.Materials and methods: In May 2010, on the same day, ten patients were operated on by the same surgeon. Five of these patients developed TASS postoperatively.Results: Patients had blurred-vision complaints on the first day after the operation, but no pain. They had different degrees of diffuse corneal edema, anterior-chamber reaction, fibrin, hypopyon, iris atrophies, and dilated pupils. Their vision decreased significantly, and their intraocular pressures increased. Both anti-inflammatory and antiglaucomatous therapies were commenced. Corneal edema and inflammation resolved in three cases; however, penetrating keratoplasty was needed for two cases and additional trabeculectomy was needed for one case. Although full investigations were undertaken at all steps, we could not find the causative agent.Conclusion: TASS is a preventable complication of anterior-segment surgery. Recognition of TASS, differentiating it from endophthalmitis, and starting treatment immediately is important. Controlling all steps in surgery, cleaning and sterilization of the instruments, and training nurses and other operation teams will help us in the prevention of TASS. Keywords: cataract, phacoemulsification, TASS, corneal edema, inflammation

  13. DELPHI's Ring Imaging Cherenkov Chamber

    CERN Multimedia

    1989-01-01

    The hundreds of mirrors around this Ring Imaging Cherenkov Chamber reflect cones of light created by fast moving particles to a detector. The velocity of a particle can be measured by the size of the ring produced on the detector. DELPHI, which ran from 1989 to 2000 on the LEP accelerator, was primarily concerned with particle identification.

  14. Bubble chamber: colour enhanced tracks

    CERN Document Server

    1998-01-01

    This artistically-enhanced image of real particle tracks was produced in the Big European Bubble Chamber (BEBC). Liquid hydrogen is used to create bubbles along the paths of the particles as a piston expands the medium. A magnetic field is produced in the detector causing the particles to travel in spirals, allowing charge and momentum to be measured.

  15. Testing an hydrogen streamer chamber

    CERN Multimedia

    1975-01-01

    A 2x10 cm gap streamer chamber, 35x55 cm2 in surface, was built and tested at CERN. Good tracks of cosmic rays were obtained up to atmospheric pressure, see F. Rohrbach et al, CERN-LAL (Orsay) Collaboration, Nucl. Instr. Methods 141 (1977) 229. Michel Cathenoz stand on the center.

  16. Chamber Music for Every Instrumentalist.

    Science.gov (United States)

    Latten, James E.

    2001-01-01

    Discusses why students who play musical instruments should participate in a chamber music ensemble. Provides rationale for using small ensembles in the high school band curriculum. Focuses on the topic of scheduling, illustrating how to insert small ensembles into the lesson schedule, and how to set up a new schedule. (CMK)

  17. A dual deformable reverberation chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2009-01-01

    There is disclosed an arrangement for measuring the effectiveness of a shielding material against electromagnetic fields. The arrangement comprises a first and a second reverberation chamber sharing a common wall. The common wall is partly made of the shielding material. A first antenna is arranged

  18. [Anterior guidance in complete dentures].

    Science.gov (United States)

    Dubreuil, J; Trevelo, A

    1990-01-01

    Although the anterior guidance in complete dentures is not really a guide, the arrangement of the anterior maxillary and mandibular prosthetic teeth, defines a propulsive line called the virtual anterior guidance, a part from the cinematic criterias. The influence of this guide on cuspal movement is superior, in all mandibular points, to the influence of the condylar pathway. If this line is not respected, the practitioner may have to do excessive grindings during occlusal adjustments.

  19. Multidisciplinary management of anterior diastemata

    DEFF Research Database (Denmark)

    Furuse, Adilson Yoshio; Herkrath, Fernando José; Franco, Eduardo Jacomino

    2007-01-01

    Anterior diastemata may compromise the harmony of a patient's smile. Consideration of etiologic factors, previous gingival conditioning, and individual treatment planning are essential in the proper management of anterior diastemata. An integrated orthodontic-restorative approach may enhance...... the aesthetic results when orthodontic therapy itself is not feasible. This article presents integrated orthodonticrestorative solutions of anterior diastemata, associated with the conditioning of the gingival tissue with composite resin, and discusses the most relevant aspects related to their etiology...

  20. Characterization of an extrapolation chamber in a 90Sr/90Y beta radiation field

    International Nuclear Information System (INIS)

    Oramas Polo, I.; Tamayo Garcia, J. A.

    2015-01-01

    The extrapolation chamber is a parallel plate chamber and variable volume based on the Bragg-Gray theory. It determines in absolute mode, with high accuracy the dose absorbed by the extrapolation of the ionization current measured for a null distance between the electrodes. This camera is used for dosimetry of external beta rays for radiation protection. This paper presents the characterization of an extrapolation chamber in a 90 Sr/ 90 Y beta radiation field. The absorbed dose rate to tissue at a depth of 0.07 mm was calculated and is (0.13206±0.0028) μGy. The extrapolation chamber null depth was determined and its value is 60 μm. The influence of temperature, pressure and humidity on the value of the corrected current was also evaluated. Temperature is the parameter that has more influence on this value and the influence of pressure and the humidity is not very significant. Extrapolation curves were obtained. (Author)

  1. Hydrostatic Hyperbaric Chamber Ventilation System

    Science.gov (United States)

    Sarguisingh, Miriam J.

    2012-01-01

    The hydrostatic hyperbaric chamber (HHC) represents the merger of several technologies in development for NASA aerospace applications, harnessed to directly benefit global health. NASA has significant experience developing composite hyperbaric chambers for a variety of applications. NASA also has researched the application of water-filled vessels to increase tolerance of acceleration forces. The combination of these two applications has resulted in the hydrostatic chamber, which has been conceived as a safe, affordable means of making hyperbaric oxygen therapy (HBOT) available in the developing world for the treatment of a variety of medical conditions. Specifically, HBOT is highly-desired as a possibly curative treatment for Buruli Ulcer, an infectious condition that afflicts children in sub-Saharan Africa. HBOT is simply too expensive and too dangerous to implement in the developing world using standard equipment. The HHC technology changes the paradigm. The HHC differs from standard hyperbaric chambers in that the majority of its volume is filled with water which is pressurized by oxygen being supplied in the portion of the chamber containing the patient s head. This greatly reduces the amount of oxygen required to sustain a hyperbaric atmosphere, thereby making the system more safe and economical to operate. An effort was taken to develop an HHC system to apply HBOT to children that is simple and robust enough to support transport, assembly, maintenance and operation in developing countries. This paper details the concept for an HHC ventilation and pressurization system to provide controlled pressurization and adequate washout of carbon dioxide while the subject is enclosed in the confined space during the administration of the medical treatment. The concept took into consideration operational complexity, safety to the patient and operating personnel, and physiological considerations. The simple schematic, comprised of easily acquired commercial hardware

  2. The effect of pharmacologic pupillary dilatation on anterior segment parameters in patients with exfoliation syndrome

    Directory of Open Access Journals (Sweden)

    Mehmet Cem Mocan

    2014-01-01

    Conclusion: Pupillary dilatation with a single drop of 1.0% cyclopentolate, 2.5% phenylephrine or 1% tropicamide is not associated with shallowing of the anterior chamber or narrowing of the ACA in patients with XFS who present with open angles.

  3. Manifest of depth sociopsychology

    OpenAIRE

    ZELITCHENKO ALEXANDER

    2013-01-01

    The observations of motives of activity of big groups (nations, confessions etc.) as a whole result in discovery of the part of unconscious mind that is common for all members of big group a collective unconscious. Two parts of collective unconscious may be determined: the collective superconscious known first as a group archetype and the collective subconscious, which manifest itself for example in phenomenon of collective trauma. Depth sociopsychology is a science about the collective uncon...

  4. Bioengineered anterior cruciate ligament

    Science.gov (United States)

    Altman, Gregory (Inventor); Kaplan, David (Inventor); Vunjak-Novakovic, Gordana (Inventor); Martin, Ivan (Inventor)

    2001-01-01

    The present invention provides a method for producing an anterior cruciate ligament ex vivo. The method comprises seeding pluripotent stem cells in a three dimensional matrix, anchoring the seeded matrix by attachment to two anchors, and culturing the cells within the matrix under conditions appropriate for cell growth and regeneration, while subjecting the matrix to one or more mechanical forces via movement of one or both of the attached anchors. Bone marrow stromal cells are preferably used as the pluripotent cells in the method. Suitable matrix materials are materials to which cells can adhere, such as a gel made from collagen type I. Suitable anchor materials are materials to which the matrix can attach, such as Goinopra coral and also demineralized bone. Optimally, the mechanical forces to which the matrix is subjected mimic mechanical stimuli experienced by an anterior cruciate ligament in vivo. This is accomplished by delivering the appropriate combination of tension, compression, torsion, and shear, to the matrix. The bioengineered ligament which is produced by this method is characterized by a cellular orientation and/or matrix crimp pattern in the direction of the applied mechanical forces, and also by the production of collagen type I, collagen type III, and fibronectin proteins along the axis of mechanical load produced by the mechanical forces. Optimally, the ligament produced has fiber bundles which are arranged into a helical organization. The method for producing an anterior cruciate ligament can be adapted to produce a wide range of tissue types ex vivo by adapting the anchor size and attachment sites to reflect the size of the specific type of tissue to be produced, and also adapting the specific combination of forces applied, to mimic the mechanical stimuli experienced in vivo by the specific type of tissue to be produced. The methods of the present invention can be further modified to incorporate other stimuli experienced in vivo by the

  5. Pencil-shaped radiation detection ionization chamber

    International Nuclear Information System (INIS)

    Suzuki, A.

    1979-01-01

    A radiation detection ionization chamber is described. It consists of an elongated cylindrical pencil-shaped tubing forming an outer wall of the chamber and a center electrode disposed along the major axis of the tubing. The length of the chamber is substantially greater than the diameter. A cable connecting portion at one end of the chamber is provided for connecting the chamber to a triaxial cable. An end support portion is connected at the other end of the chamber for supporting and tensioning the center electrode. 17 claims

  6. LEP vacuum chamber, early prototype

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    The structure of LEP, with long bending magnets and little access to the vacuum chamber between them, required distributed pumping. This is an early prototype for the LEP vacuum chamber, made from extruded aluminium. The main opening is for the beam. The small channel to the right is for cooling water, to carry away the heat deposited by the synchroton radiation from the beam. The 4 slots in the channel to the left house the strip-shaped ion-getter pumps (see 7810255). The ion-getter pumps depended on the magnetic field of the bending magnets, too low at injection energy for the pumps to function well. Also, a different design was required outside the bending magnets. This design was therefore abandoned, in favour of a thermal getter pump (see 8301153 and 8305170).

  7. Development of multiwire proportional chambers

    CERN Document Server

    Charpak, G

    1969-01-01

    It has happened quite often in the history of science that theoreticians, confronted with some major difficulty, have successfully gone back thirty years to look at ideas that had then been thrown overboard. But it is rare that experimentalists go back thirty years to look again at equipment which had become out-dated. This is what Charpak and his colleagues did to emerge with the 'multiwire proportional chamber' which has several new features making it a very useful addition to the armoury of particle detectors. In the 1930s, ion-chambers, Geiger- Muller counters and proportional counters, were vital pieces of equipment in nuclear physics research. Other types of detectors have since largely replaced them but now the proportional counter, in new array, is making a comeback.

  8. Single wire drift chamber design

    Energy Technology Data Exchange (ETDEWEB)

    Krider, J.

    1987-03-30

    This report summarizes the design and prototype tests of single wire drift chambers to be used in Fermilab test beam lines. The goal is to build simple, reliable detectors which require a minimum of electronics. Spatial resolution should match the 300 ..mu..m rms resolution of the 1 mm proportional chambers that they will replace. The detectors will be used in beams with particle rates up to 20 KHz. Single track efficiency should be at least 99%. The first application will be in the MT beamline, which has been designed for calibration of CDF detectors. A set of four x-y modules will be used to track and measure the momentum of beam particles.

  9. Calibration and performance of a stirred benthic chamber

    Science.gov (United States)

    Buchholtz-ten Brink, M. R.; Gust, G.; Chavis, D.

    1989-07-01

    The physical and chemical boundary layer parameters characteristic for a benthic chamber were cross-calibrated by the use of two methods in the laboratory: (1) flush-mounted hot-film sensors, which measure the friction velocity u ∗, and (2) the alabaster dissolution technique, which measures the equivalent film thickness z. Tests of five stirring devices were made, using both techniques, to improve the stirring mechanism in the MANOP Lander flux chambers. The stirring device that was finally implemented consisted of four rods and produced spatially averaged friction velocities u ∗ ranging from 0.1 to 0.5 cm s -1 (i.e. mean film thickness z from 500 to 180 μm) when running at speeds from 3 to 9 rpm. The friction velocity field at the sediment surface is related to the rpm of the stirring device and the penetration depth of the chamber into the sediments; combinations of both can create z and u ∗ inside the chamber that duplicate those of many natural environments. The log-log calibration relationship found between u ∗ and transfer coefficients K' also provides a means to predict the mass-transfer resistance of solutes at the sediment-water interface from measurements of mean bottom stress.

  10. A mathematical model of aerosol holding chambers

    DEFF Research Database (Denmark)

    Zak, M; Madsen, J; Berg, E

    1999-01-01

    A mathematical model of aerosol delivery from holding chambers (spacers) was developed incorporating tidal volume (VT), chamber volume (Vch), apparatus dead space (VD), effect of valve insufficiency and other leaks, loss of aerosol by immediate impact on the chamber wall, and fallout of aerosol...... in the chamber with time. Four different spacers were connected via filters to a mechanical lung model, and aerosol delivery during "breathing" was determined from drug recovery from the filters. The formula correctly predicted the delivery of budesonide aerosol from the AeroChamber (Trudell Medical, London......-mentioned factors, initial loss of aerosol by impact on the chamber wall is most important for the efficiency of a spacer. With a VT of 195 mL, the AeroChamber and Babyhaler were emptied in two breaths, the NebuChamber in four breaths, and the Nebuhaler in six breaths. Insufficiencies of the expiratory valves were...

  11. The KEK 1 m hydrogen bubble chamber

    International Nuclear Information System (INIS)

    Doi, Yoshikuni; Araoka, Osamu; Hayashi, Kohei; Hayashi, Yoshio; Hirabayashi, Hiromi.

    1978-03-01

    A medium size hydrogen bubble chamber has been constructed at the National Laboratory for High Energy Physics, KEK. The bubble chamber has been designed to be operated with a maximum rate of three times per half a second in every two second repetition time of the accelerator, by utilizing a hydraulic expansion system. The bubble chamber has a one meter diameter and a visible volume of about 280 l. A three-view stereo camera system is used for taking photographic pictures of the chamber. A 2 MW bubble chamber magnet is constructed. The main part of the bubble chamber vessel is supported by the magnet yoke. The magnet gives a maximum field of 18.4 kG at the centre of the fiducial volume of the chamber. The overall system of the KEK 1 m hydrogen bubble chamber facility is described in some detail. Some operational characteristics of the facility are also reported. (auth.)

  12. GBO RF Anechoic Chamber & Antenna Test Range

    Data.gov (United States)

    Federal Laboratory Consortium — A shielded anechoic chamber measuring 15 by 15 by 37 feet is located in the Jansky Laboratory at Green Bank. This chamber has been outfitted as a far-field antenna...

  13. Inestabilidad Anterior de Hombro

    Directory of Open Access Journals (Sweden)

    Pablo David Flint Kuran

    2013-11-01

    Full Text Available In­tro­duc­ción La luxación recidivante de hombro es una patología frecuente en pacientes jóvenes, laboralmente activos. Existen numerosas técnicas quirúrgicas para la inestabilidad glenohumeral. La técnica de Bristow, discutida por no ser anatómica y por sus complicaciones, continúa vigente debido al bajo índice de reluxaciones. Los objetivos fueron determinar el índice de recidiva, alteraciones funcionales e índice de consolidación del injerto. Materiales­ y­ Métodos Se evaluaron 24 pacientes del sexo masculino, de entre 19 y 40 años, operados por luxación anterior recidivante de hombro según la técnica de Bristow, entre enero de 2003 y agosto de 2011. Se evaluó la tasa de reluxación, la función articular según el puntaje de Constant y el posicionamiento del injerto con respecto a la superficie articular con tomografía y radiografías para evaluar la consolidación del injerto. Se registraron las complicaciones quirúrgicas. Resultados ­Todos los pacientes eran hombres, con rango de edad de 19 a 40 años. La causa fue traumática en 24 pacientes. Dieciséis pacientes presentaron más de 3 episodios de luxación prequirúrgicos. Según la escala de Constant, 21 obtuvieron entre 96 y 100 puntos, y los restantes, entre 90 y 95 puntos. No hubo nuevos episodios de luxaciones. La tomografía mostró la consolidación en todos los casos. Un paciente tuvo una imagen osteolítica alrededor del tornillo, sin compromiso funcional del hombro. Conclusión La técnica de Bristow para tratar la luxación anterior recidivante de hombro provocó un bajo índice de complicaciones, con resultados funcionales entre excelentes y buenos. No hubo episodios de reluxación y se logró la consolidación del injerto óseo en todos los casos.

  14. Simple Cloud Chambers Using Gel Ice Packs

    Science.gov (United States)

    Kamata, Masahiro; Kubota, Miki

    2012-01-01

    Although cloud chambers are highly regarded as teaching aids for radiation education, school teachers have difficulty in using cloud chambers because they have to prepare dry ice or liquid nitrogen before the experiment. We developed a very simple and inexpensive cloud chamber that uses the contents of gel ice packs which can substitute for dry…

  15. Vacuum chamber at intersection I-6

    CERN Multimedia

    1971-01-01

    The vacuum chamber at intersection region I-6, one of these where experiments in colliding-beam physics will be taking place. The "wheels" prevent the thin wall (1.5 mm) of the chamber from collapsing. The chamber is equipped with heating tapes and its wrapped in thermal insulation. Residual gas pressure at this and other similar regions is around 10_11.

  16. Impedances in lossy elliptical vacuum chambers

    International Nuclear Information System (INIS)

    Piwinski, A.

    1994-04-01

    The wake fields of a bunched beam caused by the resistivity of the chamber walls are investigated for a vacuum chamber with elliptical cross section. The longitudinal and transverse impedances are calculated for arbitrary energies and for an arbitrary position of the beam in the chamber. (orig.)

  17. Vacuum chamber for an undulator straight section

    International Nuclear Information System (INIS)

    Kim, S.; Wehrle, R.; Genens, L.

    1987-01-01

    A prototype aluminum extruded vacuum chamber for an undulator straight section of the Advanced Photon Source is described. The 52.-m long vacuum system is designed so that the undulator gap variation does not interfere with it. The chamber is gripped in a stiff close toleranced mounting structure to insure dimensional tolerance of the chamber height

  18. Proportional chambers and multiwire drift chambers at high rates

    International Nuclear Information System (INIS)

    Walenta, A.H.

    1977-01-01

    The high event and particle rates expected for ISABELLE intersecting storage rings raise the question whether PWC's and drift chambers, now widely in use in experiments, still can operate under such conditions. Various effects depend on the number of avalanches produced per length of wire N and the size of the avalanche Q, i.e., on the number of positive ions created in an avalanche. Therefore the important parameter for the following discussion is the product QN. The minimum Q is determined by the type and noise level of preamplifiers used. Examples are given for a typical low noise amplifier as well as for a typical integrated ''cheap'' amplifier. The rate/wire length N depends on the chamber arrangement, wire spacing, etc. In multiwire drift chambers, a single wire shows space-charge effects reducing the pulse height by 1% at a rate of N = 7 x 10 3 mm -1 sec -1 . At a rate of N approximately equal to 10 5 mm -1 sec -1 an efficiency loss of the order of 1% was noticed. The aging effect due to deposits on the anode wire can be reduced using low noise amplifiers and low gas gain to such an extent that a lifetime of about half a year at ISABELLE can be expected. The use of conventional cheap preamplifiers will result in a typical lifetime of about 30 days. Improvements are probable. The time resolution of Δt/sub r/ = 4 nsec fwhm seems adequate for event rates of 10 7 sec -1 . The memory time Δt/sub m/ greater than or equal to 100 nsec may cause serious problems for pattern recognition depending on layout and readout. The use of induced signals on cathode pads, thus reading out shorter parts of the wire, can solve the problem

  19. Anterior ankle arthrodesis

    Science.gov (United States)

    Slater, Gordon L; Sayres, Stephanie C; O’Malley, Martin J

    2014-01-01

    Ankle arthrodesis is a common procedure that resolves many conditions of the foot and ankle; however, complications following this procedure are often reported and vary depending on the fixation technique. Various techniques have been described in the attempt to achieve ankle arthrodesis and there is much debate as to the efficiency of each one. This study aims to evaluate the efficiency of anterior plating in ankle arthrodesis using customised and Synthes TomoFix plates. We present the outcomes of 28 ankle arthrodeses between 2005 and 2012, specifically examining rate of union, patient-reported outcomes scores, and complications. All 28 patients achieved radiographic union at an average of 36 wk; the majority of patients (92.86%) at or before 16 wk, the exceptions being two patients with Charcot joints who were noted to have bony union at a three year review. Patient-reported outcomes scores significantly increased (P plate offers added compression and provides a rigid fixation for arthrodesis stabilization. PMID:24649408

  20. Anterior Segment Tomography with the Cirrus Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Eduardo B. Rodrigues

    2012-01-01

    Full Text Available Optical coherence tomography (OCT is an optical acquisition method to examine biological tissues. In recent years, OCT has become an important imaging technology used in diagnosing and following macular pathologies. Further development enabled application of optical coherence tomography in evaluation of the integrity of the nerve fiber layer, optic nerve cupping, anterior chamber angle, or corneal topography. In this manuscript we overview the use of OCT in the clinical practice to enable corneal, iris, ciliary body, and angle evaluation and diagnostics.

  1. Ion collection efficiency of ionization chambers in electron beams

    International Nuclear Information System (INIS)

    Garcia, S.; Cecatti, E.R.

    1984-01-01

    When ionization chambers are used in pulsed radiation beams the high-density of ions produced per pulse permits ion recombination, demanding the use of a correction factor. An experimental technique using the charge collected at two different voltages permits the calculation of the ion collection efficiency. The ion collection efficiency of some common ionization chambers in pulsed electron beams were studied as a function of electron energy, dose rate and depth. Accelerators with magnetic scanning system, in which the instantaneous dose rate is much greater than the average dose rate, present a smaller collection efficiency than accelerators with scattering foil. The results lead to the introduction of a correction factor for ion recombination that is the reciprocal of the ion collection efficiency. It is also suggested a simple technique to connect an external variable DC power supply in a Baldwin Farmer dosemeter. (Author) [pt

  2. Dual versus single Scheimpflug camera for anterior segment analysis: Precision and agreement.

    Science.gov (United States)

    Aramberri, Jaime; Araiz, Luis; Garcia, Ane; Illarramendi, Igor; Olmos, Jaione; Oyanarte, Izaskun; Romay, Amaya; Vigara, Itxaso

    2012-11-01

    To assess the repeatability, reproducibility, and agreement of the Pentacam HR single-camera and Galilei G2 dual-camera Scheimpflug devices in anterior segment analysis. Begitek Clínica Oftalmológica, San Sebastián, Spain. Prospective randomized observational study. Healthy young individuals had 3 consecutive tests by 2 examiners. Analyzed parameters were anterior and posterior cornea simulated keratometry (K), K flat, K steep, astigmatism magnitude and axis, J(0) and J(45) vectors, asphericity, total corneal higher-order wavefront aberrations (root mean square [RMS], coma, trefoil, spherical aberration), central cornea and thinnest-point thicknesses, and anterior chamber depth. Repeatability and reproducibility were evaluated by calculating the within-subject standard deviation (S(w)), some derived coefficients, and the intraclass correlation coefficient. Agreement was assessed with the Bland-Altman method. The single-camera device reproducibility (S(w)) was simulated K, 0.04 diopter (D); J(0), 0.03 D; J(45), 0.04 D; total power, 0.04 D; spherical aberration, 0.02 μm; higher-order aberrations (HOAs), 0.02 μm; central corneal thickness (CCT), 3.39 μm. The dual-camera device S(w) was simulated K, 0.07 D; J(0), 0.13 D; J(45), 0.04 D; total power, 0.08 D; spherical aberration, 0.02 μm; HOAs, 0.11 μm; CCT, 1.36 μm. Agreement was good for most parameters except total corneal power (mean difference 1.58 D ± 0.22 (SD) and HOA RMS (mean difference 0.48 ± 0.19 μm) (both PAramberri is consultant to Costruzione Strumenti Oftalmici, Firenze, Italy. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Vitrectorhexis and lens aspiration with posterior chamber intraocular lens implantation in spherophakia.

    Science.gov (United States)

    Al-Haddad, Christiane; Khatib, Lama

    2012-07-01

    We describe a technique that uses the vitrector to perform successful lens aspiration and posterior chamber intraocular lens (IOL) implantation in children with spherophakia and anterior lens subluxation. After an anterior chamber maintainer is placed, the ocutome is introduced through a limbal incision to perform a circular vitrectorhexis to avoid excessive manipulation of the unstable lens followed by gentle cortex aspiration. A foldable IOL is injected into the sulcus (3-piece IOL) or bag (1-piece IOL) if the capsule is sufficiently stable. Through a pars plana incision, the ocutome is then used to perform a posterior capsulotomy to prevent late posterior capsule opacification. In our patient, sulcus IOL placement was more stable than in-the-bag placement. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. The Effects of Various Water Table Depths on CO2 Emission at Oil Palm Plantation on West Aceh Peat

    Directory of Open Access Journals (Sweden)

    Etik Puji Handayani

    2010-09-01

    Full Text Available Changes in the depth of water table influenced carbon cycling in peatlands, and affected the sources and sinks of carbon dioxide. The effects of depth of water tables in oil palm plantations on the emission of CO2 were studied. CO2 emissions of peatland were measured in Meulaboh, West Aceh using cylindrical chambers and air samples from the chambers were analyzed by gas chromatography. Five-point transects perpendicular to drainage canals provided variation in the depth of water tables for the samples. Data from oil palm fields were compared to data from an adjacent swamp forest. The data confirmed that the increasing depth of water table was accompanied by the increasing in microbial activity that was measured by CO2 emission. The CO2 emissions from chambers with additional root zones were higher than from bulk soil chambers between one to four times.

  5. Depth Echolocation Learnt by Novice Sighted People.

    Directory of Open Access Journals (Sweden)

    Alessia Tonelli

    Full Text Available Some blind people have developed a unique technique, called echolocation, to orient themselves in unknown environments. More specifically, by self-generating a clicking noise with the tongue, echolocators gain knowledge about the external environment by perceiving more detailed object features. It is not clear to date whether sighted individuals can also develop such an extremely useful technique. To investigate this, here we test the ability of novice sighted participants to perform a depth echolocation task. Moreover, in order to evaluate whether the type of room (anechoic or reverberant and the type of clicking sound (with the tongue or with the hands influences the learning of this technique, we divided the entire sample into four groups. Half of the participants produced the clicking sound with their tongue, the other half with their hands. Half of the participants performed the task in an anechoic chamber, the other half in a reverberant room. Subjects stood in front of five bars, each of a different size, and at five different distances from the subject. The dimension of the bars ensured a constant subtended angle for the five distances considered. The task was to identify the correct distance of the bar. We found that, even by the second session, the participants were able to judge the correct depth of the bar at a rate greater than chance. Improvements in both precision and accuracy were observed in all experimental sessions. More interestingly, we found significantly better performance in the reverberant room than in the anechoic chamber. The type of clicking did not modulate our results. This suggests that the echolocation technique can also be learned by sighted individuals and that room reverberation can influence this learning process. More generally, this study shows that total loss of sight is not a prerequisite for echolocation skills this suggests important potential implications on rehabilitation settings for persons with

  6. Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophies

    Directory of Open Access Journals (Sweden)

    Anna K. Nowinska

    2015-01-01

    Full Text Available Purpose. To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT in eyes with corneal dystrophies (CDs. Methods. Fifty healthy volunteers (50 eyes and 54 patients (96 eyes diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT, anterior chamber depth (ACD, and nasal and temporal trabecular iris angle (nTIA, tTIA were measured and compared with Bland-Altman plots. Results. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Conclusions. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements.

  7. Anterior segment indocyanine green angiography in anterior scleritis and episcleritis.

    Science.gov (United States)

    Guex-Crosier, Yan; Durig, Jacques

    2003-09-01

    To evaluate the pattern of anterior segment indocyanine green (ICG) angiography in episcleritis and scleritis. Prospective comparative (paired-eye) observational case series. Twenty subjects presenting clinical diseases compatible with episcleritis or scleritis. Anterior segment ICG angiography was performed according to a standard protocol in subjects presenting either episcleritis or scleritis. Photographs of the anterior segment were taken in the early phase (up to 3 minutes after dye injection), intermediate phase (10-12 minutes) and late phase (30-45 minutes). The inflamed zones were compared with the same regions of the controlateral eye. The amount of protein ICG exudation was scored by a masked observer as follows: zero for no exudation, one for slight exudation, two for moderate exudation, and three for severe exudation. Evaluation of dye leakage, which reflects protein exudation, with anterior segment ICG angiography in episcleritis and scleritis. Twenty subjects with a mean age of 43 +/- 15 years (7 male, 13 female) were enrolled in the study. Thirteen subjects had anterior scleritis (7 nodular, 5 diffuse, and 1 scleromalacia perforans), and 7 subjects had episcleritis. Only 1 out of 7 subjects with episcleritis showed a slight ICG leakage (a score of one), whereas all subjects with scleritis had ICG leakage scores of one or more (P = 0.0005, Fisher exact test). ICG angiography of the anterior segment of the eye is a good clinical test to differentiate episcleritis from scleritis.

  8. Loss of ions in cavity ionization chambers

    International Nuclear Information System (INIS)

    Takata, N.; Tran, N.T.; Kim, E.; Marsoem, P.; Kurosawa, T.; Koyama, Y.

    2005-01-01

    Ion losses due to initial recombination, volume recombination, and back diffusion were each determined by measurements and calculations for different size cylindrical ionization chambers and spherical ionization chambers. By measuring signal currents from these ionization chambers irradiated with 60 Co gamma rays, two groups of ion losses were obtained. (Group 1) Ion loss due to initial recombination and diffusion, which changes proportionally to the inverse of the voltage applied to the ionization chambers; (and group 2) ion loss due to volume recombination, which changes proportionally to the inverse of the square of the applied voltage. The diffusion loss was obtained separately by computing electric field distributions in the ionization chambers. It was found that diffusion loss is larger than initial recombination loss for the cylindrical ionization chambers and vise versa for the spherical ionization chambers

  9. Growing and analyzing biofilms in flow chambers

    DEFF Research Database (Denmark)

    Tolker-Nielsen, Tim; Sternberg, Claus

    2011-01-01

    conditions, and the environment can be carefully controlled and easily changed. The protocols in this unit include construction of the flow chamber and the bubble trap, assembly and sterilization of the flow chamber system, inoculation of the flow chambers, running of the system, image capture and analysis......This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic......, and disassembly and cleaning of the system. In addition, embedding and fluorescent in situ hybridization of flow chamber-grown biofilms are addressed....

  10. TRU waste characterization chamber gloveboxes

    International Nuclear Information System (INIS)

    Duncan, D. S.

    1998-01-01

    Argonne National Laboratory-West (ANL-W) is participating in the Department of Energy's (DOE) National Transuranic Waste Program in support of the Waste Isolation Pilot Plant (WIPP). The Laboratory's support currently consists of intrusive characterization of a selected population of drums containing transuranic waste. This characterization is performed in a complex of alpha containment gloveboxes termed the Waste Characterization Gloveboxes. Made up of the Waste Characterization Chamber, Sample Preparation Glovebox, and the Equipment Repair Glovebox, they were designed as a small production characterization facility for support of the Idaho National Engineering and Environmental Laboratory (INEEL). This paper presents salient features of these gloveboxes

  11. Nova target chamber decontamination study

    International Nuclear Information System (INIS)

    1979-05-01

    An engineering study was performed to determine the most effective method for decontamination of the Nova target chamber. Manual and remote decontamination methods currently being used were surveyed. In addition, a concept that may not require in-situ decontamination was investigated. Based on the presently available information concerning material and system compatibility and particle penetration, it is recommended that a system of removable aluminum shields be considered. It is also recommended that a series of tests be performed to more precisely determine the vacuum compatibility and penetrability of other materials discussed in this report

  12. Experimental work on drift chambers

    International Nuclear Information System (INIS)

    Alcaraz, J.; Duran, I.; Gonzalez, E.; Martinez-Laso, L.; Olmos, P.

    1989-01-01

    An experimental work made on drift chambers is described in two chapters. In the firt chapter we present the description of the experimental installation used, as well as some details on the data adquisition systems and the characteristics on three ways used for calibration proposes (cosmic muons, β radiation and test beam using SPS at CERN facilities). The second chapter describes the defferent prototypes studied. The experimental set up and the analysis are given. Some results are discussed. The magnetic field effect is also studied. (Author)

  13. Estimation and relevance of depth correction in paediatric renal studies

    International Nuclear Information System (INIS)

    Lythgoe, M.F.; Gradwell, M.J.; Evans, K.; Gordon, I.

    1998-01-01

    Measurement of absolute renal function by gamma camera techniques requires knowledge of kidney depth to correct for soft tissue attenuation, there is debate about the need to take depth into account when only relative renal function is estimated. The aim of this study was to derive a formula for renal depth in children and to assess the importance of depth correction when relative renal function is assessed with dimercaptosuccinic acid (DMSA) on the gamma camera. In this study, kidney depths were derived from measurements on abdominal computerised tomography (CT) images in 57 children in the supine position with two normally located kidneys. Using best-subset regression analysis, one formula for both left and right kidney depth (KD, cm) was developed based on the easily measured parameters of height (H, cm) and body weight (W, kg). The inclusion of extra variables was found to significantly improve the model compared with a model using weight alone (P<0.005). A second group of 19 children who underwent technetium-99m DMSA scans, had differential function estimated from both anterior and posterior views and the geometric mean method. The mean difference in differential renal function calculated by the geometric mean method versus the posterior image was only 1.2%. In conclusion, we present a new formula for the estimation of paediatric kidney depth for the absolute quantitation of kidney uptake. Further, for normally located kidneys it appears unnecessary to use the geometric mean method or to correct for individual renal depth when calculating differential function. (orig.)

  14. MR determination of neonatal spinal canal depth

    Energy Technology Data Exchange (ETDEWEB)

    Arthurs, Owen, E-mail: owenarthurs@uk2.net [Centre for Cardiovascular MR, Great Ormond Street Hospital for Children, London WC1N 3JH (United Kingdom); Thayyil, Sudhin, E-mail: s.thayyil@ucl.ac.uk [Academic Neonatology, Institute for Women' s Health, London WC1E 6AU (United Kingdom); Wade, Angie, E-mail: a.wade@ucl.ac.uk [Centre for Paediatric Epidemiology and Biostatistics, UCL Institute of Child Health, London (United Kingdom); Chong, W.K., E-mail: Kling.Chong@gosh.nhs.uk [Paediatric Neuroradiology, Great Ormond Street Hospital for Children, London (United Kingdom); Sebire, Neil J., E-mail: Neil.Sebire@gosh.nhs.uk [Histopathology, Great Ormond Street Hospital for Children, London WC1E 6AU (United Kingdom); Taylor, Andrew M., E-mail: a.taylor76@ucl.ac.uk [Centre for Cardiovascular MR, Cardiorespiratory Unit, Great Ormond Street Hospital for Children and UCL Institute of Cardiovascular Science, London WC1E 6AU (United Kingdom)

    2012-08-15

    Objectives: Lumbar punctures (LPs) are frequently performed in neonates and often result in traumatic haemorrhagic taps. Knowledge of the distance from the skin to the middle of the spinal canal (mid-spinal canal depth - MSCD) may reduce the incidence of traumatic taps, but there is little data in extremely premature or low birth weight neonates. Here, we determined the spinal canal depth at post-mortem in perinatal deaths using magnetic resonance imaging (MRI). Patients and methods: Spinal canal depth was measured in 78 post-mortem foetuses and perinatal cases (mean gestation 26 weeks; mean weight 1.04 kg) at the L3/L4 inter-vertebral space at post-mortem MRI. Both anterior (ASCD) and posterior (PSCD) spinal canal depth were measured; MSCD was calculated and modelled against weight and gestational age. Results: ASCD and PSCD (mm) correlated significantly with weight and gestational age (all r > 0.8). A simple linear model MSCD (mm) = 3 Multiplication-Sign Weight (kg) + 5 was the best fit, identifying an SCD value within the correct range for 87.2% (68/78) (95% CI (78.0, 92.9%)) cases. Gestational age did not add significantly to the predictive value of the model. Conclusion: There is a significant correlation between MSCD and body weight at post-mortem MRI in foetuses and perinatal deaths. If this association holds in preterm neonates, use of the formula MSCD (mm) = 3 Multiplication-Sign Weight (kg) + 5 could result in fewer traumatic LPs in this population.

  15. Institutional Strength in Depth

    International Nuclear Information System (INIS)

    Weightman, M.

    2016-01-01

    Much work has been undertaken in order to identify, learn and implement the lessons from the TEPCO Fukushima Daiichi nuclear accident. These have mainly targeted on engineering or operational lessons. Less attention has been paid to the institutional lessons, although there have been some measures to improve individual peer reviews, particularly by the World Association of Nuclear Operators, and the authoritative IAEA report published in 2015 brought forward several important lessons for regulators and advocated a system approach. The report noted that one of the contributing factors the accident was the tendency of stakeholders not to challenge. Additionally, it reported deficiencies in the regulatory authority and system. Earlier, the root cause of the accident was identified by a Japanese independent parliamentary report as being cultural and institutional. The sum total of the institutions, the safety system, was ineffective. While it is important to address the many technical and operational lessons these may not necessary address this more fundamental lesson, and may not serve to provide robust defences against human or institutional failings over a wide variety of possible events and combinations. The overall lesson is that we can have rigorous and comprehensive safety standards and other tools in place to deliver high levels of safety, but ultimately what is important is the ability of the nuclear safety system to ensure that the relevant institutions diligently and effectively apply those standards and tools — to be robust and resilient. This has led to the consideration of applying the principles of the strength in depth philosophy to a nuclear safety system as a way of providing a framework for developing, assessing, reviewing and improving the system. At an IAEA conference in October 2013, a model was presented for a robust national nuclear safety system based on strength in depth philosophy. The model highlighted three main layers: industry, the

  16. Offshore Wind Technology Depth Zones

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Coastal bathymetric depth, measured in meters at depth values of: -30, -60, -900 Shallow Zone (0-30m): Technology has been demonstrated on a commercial scale at...

  17. Anterior Knee Pain (Chondromalacia Patellae).

    Science.gov (United States)

    Garrick, James G.

    1989-01-01

    This article presents a pragmatic approach to the definition, diagnosis, and management of anterior knee pain. Symptoms and treatment are described. Emphasis is on active involvement of the patient in the rehabilitation exercise program. (IAH)

  18. Anterior approach for knee arthrography

    International Nuclear Information System (INIS)

    Zurlo, J.V.; Towers, J.D.; Golla, S.

    2001-01-01

    Objective. To develop a new method of magnetic resonance arthrography (MRA) of the knee using an anterior approach analogous to the portals used for knee arthroscopy.Design. An anterior approach to the knee joint was devised mimicking anterior portals used for knee arthroscopy. Seven patients scheduled for routine knee MRA were placed in a decubitus position and under fluoroscopic guidance a needle was advanced from a position adjacent to the patellar tendon into the knee joint. After confirmation of the needle tip location, a dilute gadolinium solution was injected.Results and conclusion. All the arthrograms were technically successful. The anterior approach to knee MRA has greater technical ease than the traditional approach with little patient discomfort. (orig.)

  19. Limits to Drift Chamber Resolution

    CERN Document Server

    Riegler, Werner

    1998-01-01

    ATLAS (A Large Toroidal LHC Apparatus) will be a general-purpose experiment at the Large Hadron Collider that will be operational at CERN in the year 2004. The ATLAS muon spectrometer aims for a momentum resolution of 10% for a transverse momentum of pT=1TeV. The precision tracking devices in the muon system will be high pressure drift tubes (MDTs) with a single wire resolution of 1100 chambers covering an area of ≈ 2500m2. The high counting rates in the spectrometer as well as the aim for excellent spatial resolution and high efficiency put severe constraints on the MDT operating parameters. This work describes a detailed study of all the resolution limiting factors in the ATLAS environment. A ’full chain’ simulation of the MDT response to photons and charged particles as well as quantitative comparisons with measurements was performed. The good agreement between simulation and measurements resulted in a profound understanding of the drift chamber processes and the individual contributions to the spat...

  20. Neutron Detection with Bubble Chambers

    Science.gov (United States)

    Ghilea, M. C.; Lerche, R. A.; Disdier, L.

    2005-10-01

    To improve neutron imaging resolution, we have developed a general imaging design tool for inertial confinement fusion facilities that can simulate aperture errors, generate arbitrary neutron source distributions, simulate arbitrary aperture shapes, calculate point-spread functions using ray tracing, and reconstruct source images using a variety of filter functions. Predicted system performance can be compared to various concepts before construction. This software design tool is being developed for the UR/LLE OMEGA laser and the NIF as part of a process to design and build an imaging system based on a bubble chamber detectorootnotetextR. A. Lerche et al., Rev. Sci. Instrum. 74, 1709 (2003). for the UR/LLE OMEGA laser. This talk will present the latest results on aperture contributions to system performance and review the conceptual design of the bubble chamber-based imaging system, its conceptual design being reviewed in the second part of the presentation. This work was supported by the U.S. Department of Energy Office of Inertial Confinement Fusion under Cooperative Agreement No. DE-FC52-92SF19460.

  1. Physicist makes muon chamber sing

    CERN Multimedia

    2007-01-01

    This Monitored Drift Tube detector, consisting of argon-CO2-filled aluminium tubes with a wire down the centre of each, will track muons in ATLAS; Tiecke used a single tube from one of these detectors to create the pipes in his organ. Particle physicists can make good musicians; but did you know particle detectors can make good music? That's what NIKHEF physicist Henk Tiecke learned when he used pipes cut from the ATLAS Monitored Drift Tube detector (MDT) to build his own working Dutch-style barrel organ in the autumn of 2005. 'I like to work with my hands,' said Tiecke, who worked as a senior physicist at NIKHEF, Amsterdam, on ZEUS until his retirement last summer. Tiecke had already constructed his barrel organ when he visited some colleagues in the ATLAS muon chambers production area at Nikhef in 2005. He noticed that the aluminium tubes they were using to build the chambers were about three centimetres in diameter-just the right size for a pipe in a barrel organ. 'The sound is not as nice as from wooden...

  2. Multiwire proportional chamber for Moessbauer spectroscopy: development and results

    International Nuclear Information System (INIS)

    Costa, M.S. da.

    1985-12-01

    A new Multiwere proportional Chamber designed for Moessbauer Spectroscopy is presented. This detector allows transmission backscattering experiments using either photons or electrons. The Moessbauer data acquisition system, partially developed for this work is described. A simple method for determining the frontier between true proportional and semi-proportional regions of operation in gaseous detectors is proposed. The study of the tertiary gas mixture He-Ar-CH 4 leads to a straight forward way of energy calibration of the electron spectra. Moessbauer spectra using Fe-57 source are presented. In particular those obtained with backsattered electrons show the feasibility of depth selective analysis with gaseous proportional counters. (author) [pt

  3. Landmarks for Identifying the Suprascapular Foramen Anteriorly: Application to Anterior Neurotization and Decompressive Procedures.

    Science.gov (United States)

    Manouvakhova, Olga V; Macchi, Veronica; Fries, Fabian N; Loukas, Marios; De Caro, Raffaele; Oskouian, Rod J; Spinner, Robert J; Tubbs, R Shane

    2018-02-01

    Additional landmarks for identifying the suprascapular nerve at its entrance into the suprascapular foramen from an anterior approach would be useful to the surgeon. To identify landmarks for the identification of this hidden site within an anterior approach. In 8 adult cadavers (16 sides), lines were used to connect the superior angle of the scapula, the acromion, and the coracoid process tip thus creating an anatomic triangle. The suprascapular nerve's entrance into the suprascapular foramen was documented regarding its position within this anatomical triangle. Depths from the skin surface and specifically from the medial-most point of the clavicular attachment of the trapezius to the suprascapular nerve's entrance into the suprascapular foramen were measured using calipers and a ruler. The clavicle was then fractured and retracted superiorly to verify the position of the nerve's entrance into the suprascapular foramen. From the trapezius, the nerve's entrance into the foramen was 3 to 4.2 cm deep (mean, 3.5 cm). The mean distance from the tip of the corocoid process to the suprascapular foramen was 3.8 cm. The angle best used to approach the suprascapular foramen from the surface was 15° to 20°. Based on our study, an anterior suprascapular approach to the suprascapular nerve as it enters the suprascapular foramen can identify the most medial fibers of the trapezius attachment onto the clavicle and insert a finger at an angle of 15° to 20° laterally and advanced to an average depth of 3.5 cm. Copyright © 2017 by the Congress of Neurological Surgeons

  4. Polymerase chain reaction in unilateral cases of presumed viral anterior uveitis

    Directory of Open Access Journals (Sweden)

    Shoughy SS

    2015-12-01

    Full Text Available Samir S Shoughy,1 Hind M Alkatan,2,4 Abdulelah A Al-Abdullah,2 Albarah El-Khani,2 Jolanda DF de Groot-Mijnes,3 Khalid F Tabbara1,4,5 1Department of Ophthalmology, The Eye Center and The Eye Foundation for Research in Ophthalmology, 2Department of Pathology & Laboratory Medicine and Uveitis Division, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia; 3Department of Virology and Ophthalmology, University Medical Center Utrecht, Utrecht, the Netherlands; 4Department of Ophthalmology, College of Medicine, King Saud University, Riyadh, Saudi Arabia; 5The Wilmer Ophthalmological Institute of The Johns Hopkins University School of Medicine, Baltimore, MD, USA Background and objectives: Anterior uveitis is the most common form of intraocular inflammation. The main aim of this study was to determine the viral etiology in patients with unilateral cases of anterior uveitis.Patients and methods: A total of 12 consecutive patients with the diagnosis of idiopathic unilateral anterior uveitis were included prospectively. Aqueous specimens were obtained from each patient by anterior chamber paracentesis and subjected to the detection of viral DNA/RNA genome by polymerase chain reaction assay for herpes simplex virus, varicella zoster virus, cytomegalovirus, Epstein–Barr virus, and rubella virus.Results: There were six male and six female patients. The mean age was 43 years, with an age range of 11–82 years. All 12 cases presented with unilateral anterior uveitis. In four (33% patients, polymerase chain reaction was positive for viral genome. Two patients were positive for herpes simplex virus type 1, one patient was positive for cytomegalovirus and one for Epstein–Barr virus.Conclusion: Recent molecular diagnostic assays would help in the identification of the causative agent in patients with unilateral anterior uveitis. Keywords: viral anterior uveitis, PCR, herpes simplex virus, cytomegalovirus, diffuse keratic precipitates, anterior chamber

  5. Pulp Chamber Depth Effect on Mandibular Molar EndoCrown Retention

    Science.gov (United States)

    2015-06-18

    fixed dental prosthesis that are not necessarily placed on endodontically treated teeth.25 This is the first endocrown in vitro study that...Major (Dr.) Aaron Hayes 2. Academic Title: AEGD Dental Resident 3. School/Department/Center: AF Postgraduate Dental School, Keesler AFB, MS 4. Phone...Endo Crown Retention 7. Intended publication/meeting: International Association of Dental Research Annual Meeting 8. "Required by" date: 13 Mar 2015

  6. Hydrogen depth profiling at IRMM

    Science.gov (United States)

    Persson, L.; Hult, M.; Giorginis, G.; Crametz, A.

    1997-02-01

    At the Institute for Reference Materials and Measurements (IRMM) a facility for hydrogen profiling has been implemented. Two techniques are being used; Nuclear Resonant Reaction Analysis (NRRA) using the 1H(15N,αγ)12C reaction and Elastic Recoil Detection Analysis (ERDA) using a He+ ion beam. The ERDA chamber is a common type of scattering chamber with a load lock system for quick changing of the samples. NRRA is performed in a UHV chamber in which the samples can be cooled to liquid nitrogen temperature and sputter cleaned with a 5 kV ion gun. The 4.43 MeV γ rays are detected using a 4 in.×4 in. BGO detector. Using only passive shielding a detection limit of hydrogen in silicon of 5×1018atoms/cm3 has been achieved. Experimental results which exemplify the major features of the facility are presented.

  7. Anterior ankle arthroscopy, distraction or dorsiflexion?

    NARCIS (Netherlands)

    de Leeuw, P.A.J.; Golanó, P.; Clavero, J.A.; van Dijk, C.N.

    2010-01-01

    Anterior ankle arthroscopy can basically be performed by two different methods; the dorsiflexion- or distraction method. The objective of this study was to determine the size of the anterior working area for both the dorsiflexion and distraction method. The anterior working area is anteriorly

  8. Neutron-chamber detectors and applications

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Atwater, H.F.; Coop, K.L.

    1990-01-01

    Detector applications in Nuclear Safeguards and Waste Management have included measuring neutrons from fission and (alpha,n) reactions with well-moderated neutron proportional counters, often embedded in a slab of polyethylene. Other less-moderated geometries are useful for detecting both bare and moderated fission-source neutrons with good efficiency. The neutron chamber is an undermoderated detector design comprising a large, hollow, polyethylene-walled chamber containing one or more proportional counters. Neutron-chamber detectors are relatively inexpensive; can have large apertures, usually through a thin chamber wall; and offer very good detection efficiency per dollar. Neutron-chamber detectors have also been used for monitoring vehicles and for assaying large crates of transuranic waste. Our Monte Carlo calculations for a new application (monitoring low-density waste for concealed plutonium) illustrate the advantages of the hollow-chamber design for detecting moderated fission sources. 9 refs., 6 figs., 2 tabs

  9. A mathematical model of aerosol holding chambers

    DEFF Research Database (Denmark)

    Zak, M; Madsen, J; Berg, E

    1999-01-01

    A mathematical model of aerosol delivery from holding chambers (spacers) was developed incorporating tidal volume (VT), chamber volume (Vch), apparatus dead space (VD), effect of valve insufficiency and other leaks, loss of aerosol by immediate impact on the chamber wall, and fallout of aerosol...... in the chamber with time. Four different spacers were connected via filters to a mechanical lung model, and aerosol delivery during "breathing" was determined from drug recovery from the filters. The formula correctly predicted the delivery of budesonide aerosol from the AeroChamber (Trudell Medical, London......, Ontario, Canada), NebuChamber (Astra, Södirtälje, Sweden) and Nebuhaler (Astra) adapted for babies. The dose of fluticasone proportionate delivered by the Babyhaler (Glaxco Wellcome, Oxbridge, Middlesex, UK) was 80% of that predicted, probably because of incomplete priming of this spacer. Of the above...

  10. Development of boron epoxy rocket motor chambers.

    Science.gov (United States)

    Jensen, W. M.; Knoell, A. C.; Zweben, C.

    1972-01-01

    A 71 cm diameter 74 cm length boron/epoxy composite rocket motor chamber was designed based on the geometric configuration of the JPL Applications Technology Satellite titanium alloy apogee motor chamber. Because analyses showed large stress concentrations in the domes, the configuration was modified using the same basic constraints for openings and attachments. The rocket motor chamber was then fabricated by filament winding with boron/epoxy tape and hydrostatically tested to failure at 264 N/sq cm, 57.2 N/sq cm above the design value. Two more rocket motor chambers were fabricated with the same basic constraints, but shortened to 57.6 cm for a smaller propellant load. The first of these short chambers failed in proof because of filament winding fabrication difficulties. The second chamber was successfully fabricated and passed the hydrostatic proof test.

  11. Growing and Analyzing Biofilms in Flow Chambers

    DEFF Research Database (Denmark)

    Tolker-Nielsen, Tim; Sternberg, Claus

    2011-01-01

    conditions, and the environment can be carefully controlled and easily changed. The protocols in this unit include construction of the flow chamber and the bubble trap, assembly and sterilization of the flow chamber system, inoculation of the flow chambers, running of the system, image capture and analysis......This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic......, and disassembly and cleaning of the system. In addition, embedding and fluorescent in situ hybridization of flow chamber–grown biofilms are addressed. Curr. Protoc. Microbiol. 21:1B.2.1-1B.2.17. © 2011 by John Wiley & Sons, Inc....

  12. The TOPAZ time projection chamber

    International Nuclear Information System (INIS)

    Kamae, T.; Aihara, H.; Enomoto, R.; Fujii, H.; Fujii, T.; Itoh, R.; Kusuki, N.; Miki, T.; Shirahashi, A.; Takahashi, T.; Tanaka, M.; Ikeda, H.; Iwasaki, H.; Iwata, S.; Matsuda, T.; Nakamura, K.; Yamamoto, A.; Yamauchi, M.

    1986-01-01

    A Time Projection Chamber (TPC) is under construction for the TOPAZ e + e - experiment at TRISTAN. The dimension of the TPC is 260 cm in diameter and 300 cm in axial length. Fin-type fine field cages are set inside GFRP insulator cylinders which also serve as the pressure container. The sector is made of multilayer G10 boards for better electric and thermal isolation. The cathode pads are substantially larger in area than those of the PEP4-TPC and having zigzag-shaped boundary. These serve to maintain high spatial resolution with fewer number of pad channels. Signals are amplified by low noise preamplifiers and shaping amplifiers, and, stored and digitized by FASTBUS based CCD-digitizers. Digitized information is preprocessed and sent to VAX-11/780 at a rate 2 MHz per 32 bit word. Nitrogen LASER beam will be used extensively with the LASER beacon system for calibration. Test results on production prototypes are also reported. (orig.)

  13. Picture chamber for radiographic system

    International Nuclear Information System (INIS)

    1977-01-01

    The picture chamber for a radiographic system is characterised by a base, a first electrode carried in the base, an X-ray irradiation window provided with an outer plate and an inner plate and a conducting surface which serves as a second electrode, which has a plate gripping it at each adjacent edge and which has at the sides a space which is occupied by a filling material, maintained at a steady pressure, by means of the mounting against the base and wherein the inner plate lies against the first electrode and which is provided with a split, and with means for the separation of the split in the area of the inner plate so that a fluid may be retained in the split. (G.C.)

  14. The CAST Time Projection Chamber

    CERN Document Server

    Autiero, D.; Carmona, J.M.; Cebrian, S.; Chesi, E.; Davenport, M.; Delattre, M.; Di Lella, L.; Formenti, F.; Irastorza, I.G.; Gomez, H.; Hasinoff, M.; Lakic, B.; Luzon, G.; Morales, J.; Musa, L.; Ortiz, A.; Placci, A.; Rodriguez, A.; Ruz, J.; Villar, J.A.; Zioutas, K.

    2007-01-01

    One of the three X-ray detectors of the CAST experiment searching for solar axions is a Time Projection Chamber (TPC) with a multi-wire proportional counter (MWPC) as a readout structure. Its design has been optimized to provide high sensitivity to the detection of the low intensity X-ray signal expected in the CAST experiment. A low hardware threshold of 0.8 keV is safely set during normal data taking periods, and the overall efficiency for the detection of photons coming from conversion of solar axions is 62 %. Shielding has been installed around the detector, lowering the background level to 4.10 x 10^-5 counts/cm^2/s/keV between 1 and 10 keV. During phase I of the CAST experiment the TPC has provided robust and stable operation, thus contributing with a competitive result to the overall CAST limit on axion-photon coupling and mass.

  15. Delayed bilateral fibrinous anterior chamber reaction following autologous bone marrow transplant and cataract surgery

    Directory of Open Access Journals (Sweden)

    Shaheen C. Kavoussi

    2016-07-01

    Conclusions and Importance: With a negative work-up for infectious etiologies, and the timing and clinical presentation, the patient's inflammation was likely the result of rapid white blood cell count recovery following iatrogenic immunosuppression similar to the mechanism described for IRU.

  16. Anterior Chamber Angle Shape Analysis and Classification of Glaucoma in SS-OCT Images

    Directory of Open Access Journals (Sweden)

    Soe Ni Ni

    2014-01-01

    Full Text Available Optical coherence tomography is a high resolution, rapid, and noninvasive diagnostic tool for angle closure glaucoma. In this paper, we present a new strategy for the classification of the angle closure glaucoma using morphological shape analysis of the iridocorneal angle. The angle structure configuration is quantified by the following six features: (1 mean of the continuous measurement of the angle opening distance; (2 area of the trapezoidal profile of the iridocorneal angle centered at Schwalbe's line; (3 mean of the iris curvature from the extracted iris image; (4 complex shape descriptor, fractal dimension, to quantify the complexity, or changes of iridocorneal angle; (5 ellipticity moment shape descriptor; and (6 triangularity moment shape descriptor. Then, the fuzzy k nearest neighbor (fkNN classifier is utilized for classification of angle closure glaucoma. Two hundred and sixty-four swept source optical coherence tomography (SS-OCT images from 148 patients were analyzed in this study. From the experimental results, the fkNN reveals the best classification accuracy (99.11±0.76% and AUC (0.98±0.012 with the combination of fractal dimension and biometric parameters. It showed that the proposed approach has promising potential to become a computer aided diagnostic tool for angle closure glaucoma (ACG disease.

  17. The anterior chamber angle width in adults in a tertiary eye hospital ...

    African Journals Online (AJOL)

    2011-03-25

    Mar 25, 2011 ... Materials and Methods: Consecutive new adult patients (aged ≥21 years) seen between March and July 2006 were the subjects of this study. Exclusion criteria included refusal to consent to the test, previous intraocular surgery that could distort ... lead to blindness but their treatment approach is basically.

  18. Cystercercus larva in the anterior chamber of the eye of a 7year o

    African Journals Online (AJOL)

    user

    (Hymenolepsis), and fish (Diphyllobothrium spp), and from fleas on dogs and cats (D. craninum). 1. The larva migrates to various parts of the body through the ... a private hospital with a one-week history of pain, redness and reduced vision in the left eye. There was background history of minor trauma to the eye when she ...

  19. Construction and performance of large flash chambers

    International Nuclear Information System (INIS)

    Taylor, F.E.; Bogert, D.; Fisk, R.; Stutte, L.; Walker, J.K.; Wolfson, J.; Abolins, M.; Ernwein, J.; Owen, D.; Lyons, T.

    1979-01-01

    The construction and performance of 12' x 12' flash chambers used in a 340 ton neutrino detector under construction at Fermilab is described. The flash chambers supply digital information with a spatial resolution of 0.2'', and are used to finely sample the shower development of the reaction products of neutrino interactions. The flash chambers are easy and inexpensive to build and are electronically read out

  20. Vacuum Chamber for the Booster Bending Magnets

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    To minimize eddy currents, induced by the rising magnetic field, the chamber was made from thin stainless steel of high specific electric resistance. For mechanical stength, it was corrugated in a hydro-forming process. The chamber is curved, to follow the beam's orbital path. Under vacuum, the chamber tends to staighten, the ceramic spacer along half of its length keeps it in place (see also 7402458).

  1. Bubble chamber: Omega production and decay

    CERN Multimedia

    1973-01-01

    This image is taken from one of CERN's bubble chambers and shows the decay of a positive kaon in flight. The decay products of this kaon can be seen spiraling in the magnetic field of the chamber. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that has been heated to boiling point.

  2. Drift chamber tracking with neural networks

    International Nuclear Information System (INIS)

    Lindsey, C.S.; Denby, B.; Haggerty, H.

    1992-10-01

    We discuss drift chamber tracking with a commercial log VLSI neural network chip. Voltages proportional to the drift times in a 4-layer drift chamber were presented to the Intel ETANN chip. The network was trained to provide the intercept and slope of straight tracks traversing the chamber. The outputs were recorded and later compared off line to conventional track fits. Two types of network architectures were studied. Applications of neural network tracking to high energy physics detector triggers is discussed

  3. Anechoic chamber for VHF and UHF bands

    Science.gov (United States)

    Morikawa, Takao; Sugiura, Akira; Harima, Katsushige; Masuzawa, Hiroshi

    1995-06-01

    Built in 1969, the anechoic chamber of CRL has been used to the fullest by researchers in many fields such as EMI, EMC, antenna design, standard of electric field intensity, and type approval testing. In particular, in the early days of space development in Japan, many satellite-born antennas were developed in this anechoic chamber. However, a quarter of a century has passed since its construction and deteriorated performance due to superannuation sometimes caused difficulties in experiments conducted in the chamber. In 1993, CRL constructed a Measuring Facility for Radio Research (MFRR) and the anechoic chamber for VHF-UHF bands was remodeled as one of the sub-facilities of MFRR. The remodeling work included full replacement of the electromagnetic shielding, absorbers and measurement system. Since the remodeled anechoic chamber is being used not only for EMI tests but also for other purposes, a full-anechoic chamber has been adopted. In addition the chamber has been designed for the frequency range between 30 MHz and 10 GHz. After the remodeling work, the performance of the chamber is greatly improved. The average shielding factor is better than 85 dB for all frequency ranges and the unwanted reflection characteristic is -30 dB for frequencies above 1 GHZ. This paper summarizes the remodeling work, and the specifications and performance of the remodeled anechoic chamber.

  4. Bicone vacuum chamber for ISR intersection

    CERN Multimedia

    1975-01-01

    This is one of the bicone chambers made of titanium for experiment R 702. The central corrugated part had a very thin titanium wall (0.28 mm). The first of these chambers collapsed in its central part when baked at 300 C (August 1975). After an intensive effort to develop better quality and reproducible welds for this special material, the ISR workshop was able to build two new chambers of this type. One of them was installed at I 7 for R 702 in 1976 and worked perfectly. It was at that time the most "transparent" intersection vacuum chamber. See also 7609219, 7609221.

  5. Precision Radio Frequency Anechoic Chamber Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Performs measurements and calibration of antennas for satellites and aircraft or groundbased systems. The chamber is primarily used for optimizing antenna...

  6. Biases in methane chamber measurements in peatlands

    Science.gov (United States)

    Juszczak, R.

    2013-03-01

    The paper presents results of CH4 emission measurements at peatland with the application of the dynamic chamber technique. The measurements were conducted in two types of chambers differing in shape, height, volume and technology used to assure their tightness. The study tested how the following factors: 1) forced chamber headspace mixing or its absence, 2) mistakes of the person conducting measurements, 3) improper application of linear technique for calculating CH4 fluxes, and 4) simulated air sampling typical for static chambers, influence the significance of errors and the underestimation rate of CH4 fluxes measured in situ. It was indicated that chamber headspace mixing allows estimating methane fluxes with a smaller error than in the case of measurements conducted without mixing, and CH4 fluxes in such conditions can be 47 to 58% higher (depending on the chamber type) than in a chamber without fans. Using dynamic chambers and a fast analyzer to measure methane fluxes allows shortening the methane measurement process to a few minutes. On the other hand, using static chambers for methane flux measurements may lead to 70% underestimation of the calculated flux.

  7. The Mark II Vertex Drift Chamber

    International Nuclear Information System (INIS)

    Alexander, J.P.; Baggs, R.; Fujino, D.

    1989-03-01

    We have completed constructing and begun operating the Mark II Drift Chamber Vertex Detector. The chamber, based on a modified jet cell design, achieves 30 μm spatial resolution and 2 gas mixtures. Special emphasis has been placed on controlling systematic errors including the use of novel construction techniques which permit accurate wire placement. Chamber performance has been studied with cosmic ray tracks collected with the chamber located both inside and outside the Mark II. Results on spatial resolution, average pulse shape, and some properties of CO 2 mixtures are presented. 10 refs., 12 figs., 1 tab

  8. D0 central tracking chamber performance studies

    International Nuclear Information System (INIS)

    Pizzuto, D.

    1991-12-01

    The performance of the completed DO central tracking chamber was studied using cosmic rays at the State University of New York at Stony Brook. Also studied was a prototype tracking chamber identical in design to the completed DO tracking chamber. The prototype chamber was exposed to a collimated beam of 150 GeV pions at the Fermilab NWA test facility. Results indicate an RΦ tracking resolution compatible with the limitations imposed by physical considerations, excellent 2 track resolution, and a high track reconstruction efficiency along with a good rejection power against γ → e + e - events

  9. Defence in depth perspectives

    International Nuclear Information System (INIS)

    Veneau, Tania; Ferrier, Agnes; Barbaud, Jean

    2017-01-01

    The Defence in Depth (DiD) concept was introduced to the field of nuclear safety in the sixties and early seventies. Even though it was not well developed at the beginning, the principles rapidly became close to those currently used. The concept was then composed of 3 levels, and was already associated with operating conditions. These principles have progressed over time and now there are five levels, including progressively situations issued from design extension conditions, to cope with severe accidents and dealing with accident management off-site. Indeed, human and organizational features are considered as a part of the safety provisions at all levels in an integrated approach that is not just related to reactor design. That's the current vision from IAEA, addressed first in INSAG 3 then in INSAG 10, and in the IAEA standards requirements currently addressed by SSR-2/1 superseding NS-R-1). These five levels of DiD are also referred to in other texts including WENRA documents in Europe, but also in the national requirements from different countries. Thus, the application of DiD principle has become a recognized international practice. The 2011 Fukushima Daiichi accidents, even if they raised many questions on nuclear safety issues, confirmed the merits of the DiD concept. Indeed, lessons learned from the accidents have reinforced the use of the DiD concept to ensure adequate safety. The discussions focused more on the implementation of the concept (how it has been or can be used in practice) than the concept itself, and in particular on the following subjects: the notion of level robustness, generally addressed separately from the levels definition, but playing an important role for the efficiency of the concept; the notion of levels independence and the need for strengthening them; the role of diversity to achieve levels independence. However, a prescription of additional diversity and independence across all safety levels could result in inappropriately

  10. Anterior segment sparing to reduce charged particle radiotherapy complications in uveal melanoma

    International Nuclear Information System (INIS)

    Daftari, Inder K.; Char, Devron H.; Verhey, Lynn J.; Castro, Joseph R.; Petti, Paula L.; Meecham, William J.; Kroll, Stewart; Blakely, Eleanor A.

    1997-01-01

    Purpose: The purpose of this investigation is to delineate the risk factors in the development of neovascular glaucoma (NVG) after helium-ion irradiation of uveal melanoma patients and to propose treatment technique that may reduce this risk. Methods and Materials: 347 uveal melanoma patients were treated with helium-ions using a single-port treatment technique. Using univariate and multivariate statistics, the NVG complication rate was analyzed according to the percent of anterior chamber in the radiation field, tumor size, tumor location, sex, age, dose, and other risk factors. Several University of California San Francisco-Lawrence Berkeley National Laboratory (LBNL) patients in each size category (medium, large, and extralarge) were retrospectively replanned using two ports instead of a single port. By using appropriate polar and azimuthal gaze angles or by treating patients with two ports, the maximum dose to the anterior segment of the eye can often be reduced. Although a larger volume of anterior chamber may receive a lower dose by using two ports than a single port treatment. We hypothesize that this could reduce the level of complications that result from the irradiation of the anterior chamber of the eye. Dose-volume histograms were calculated for the lens, and compared for the single and two-port techniques. Results: NVG developed in 121 (35%) patients. The risk of NVG peaked between 1 and 2.5 years posttreatment. By univariate and multivariate analysis, the percent of lens in the field was strongly correlated with the development of NVG. Other contributing factors were tumor height, history of diabetes, and vitreous hemorrhage. Dose-volume histogram analysis of single-port vs. two-port techniques demonstrate that for some patients in the medium and large category tumor groups, a significant decrease in dose to the structures in the anterior segment of the eye could have been achieved with the use of two ports. Conclusion: The development of NVG after

  11. Swimming mechanics and propulsive efficiency in the chambered nautilus

    Science.gov (United States)

    Neil, Thomas R.

    2018-01-01

    The chambered nautilus (Nautilus pompilius) encounters severe environmental hypoxia during diurnal vertical movements in the ocean. The metabolic cost of locomotion (Cmet) and swimming performance depend on how efficiently momentum is imparted to the water and how long on-board oxygen stores last. While propulsive efficiency is generally thought to be relatively low in jet propelled animals, the low Cmet in Nautilus indicates that this is not the case. We measured the wake structure in Nautilus during jet propulsion swimming, to determine their propulsive efficiency. Animals swam with either an anterior-first or posterior-first orientation. With increasing swimming speed, whole cycle propulsive efficiency increased during posterior-first swimming but decreased during anterior-first swimming, reaching a maximum of 0.76. The highest propulsive efficiencies were achieved by using an asymmetrical contractile cycle in which the fluid ejection phase was relatively longer than the refilling phase, reducing the volume flow rate of the ejected fluid. Our results demonstrate that a relatively high whole cycle propulsive efficiency underlies the low Cmet in Nautilus, representing a strategy to reduce the metabolic demands in an animal that spends a significant part of its daily life in a hypoxic environment. PMID:29515819

  12. Swimming mechanics and propulsive efficiency in the chambered nautilus

    Science.gov (United States)

    Neil, Thomas R.; Askew, Graham N.

    2018-02-01

    The chambered nautilus (Nautilus pompilius) encounters severe environmental hypoxia during diurnal vertical movements in the ocean. The metabolic cost of locomotion (Cmet) and swimming performance depend on how efficiently momentum is imparted to the water and how long on-board oxygen stores last. While propulsive efficiency is generally thought to be relatively low in jet propelled animals, the low Cmet in Nautilus indicates that this is not the case. We measured the wake structure in Nautilus during jet propulsion swimming, to determine their propulsive efficiency. Animals swam with either an anterior-first or posterior-first orientation. With increasing swimming speed, whole cycle propulsive efficiency increased during posterior-first swimming but decreased during anterior-first swimming, reaching a maximum of 0.76. The highest propulsive efficiencies were achieved by using an asymmetrical contractile cycle in which the fluid ejection phase was relatively longer than the refilling phase, reducing the volume flow rate of the ejected fluid. Our results demonstrate that a relatively high whole cycle propulsive efficiency underlies the low Cmet in Nautilus, representing a strategy to reduce the metabolic demands in an animal that spends a significant part of its daily life in a hypoxic environment.

  13. Neutron depth profiling: Overview and description of NIST facilities

    International Nuclear Information System (INIS)

    Downing, R.G.; Lamaze, G.P.; Langland, J.K.; Hwang, S.T.

    1993-01-01

    The Cold Neutron Depth Profiling (CNDP) instrument at the NIST Cold Neutron Research Facility (CNRF) is now operational. The neutron beam originates from a 16 L D 2 O ice cold source and passes through a filter of 135mm of single crystal sapphire. The neutron energy spectrum may be described by a 65 K Maxwellian distribution. The sample chamber configuration allows for remote controlled scanning of 150 x 150 mm sample areas including the varying of both sample and detector angle. The improved sensitivity over the current thermal depth profiling instrument has permitted the first nondestructive measurements of 17 O profiles. This paper describes the CNDP instrument, illustrates the neutron depth profiling (NDP) technique with examples, and gives a separate bibliography of NDP publications

  14. Clinical outcomes of pars plicata anterior vitrectomy: 2-year results

    Directory of Open Access Journals (Sweden)

    Priya Narang

    2015-01-01

    Full Text Available Purpose: To demonstrate the safety and outcome of a surgical approach that uses pars plicata site for anterior vitrectomy during phacoemulsification procedure complicated by posterior capsule rupture and residual cortical matter. Design: Single center, retrospective, interventional, noncomparative study. Materials and Methods: Medical records of a consecutive series of 35 eyes of 35 patients who underwent pars plicata anterior vitrectomy (PPAV were reviewed. The main outcome measures were corrected and uncorrected distance visual acuity (CDVA, UDVA, early and late postoperative complications and intraocular pressure (IOP. Ultrasound biomicroscopic (UBM evaluation of sclerotomy site and spectral domain optical coherence tomography analysis for central macular thickness (CMT was performed. The final visual outcome at 2 years was evaluated. Results: At 2 years follow-up, the mean postoperative UDVA (logarithm of the minimum angle of resolution [logMAR] and CDVA (logMAR was 0.49 ± 0.26 and 0.19 ± 0.14, respectively. There was no significant change in the IOP (P = 0.061 and the mean CMT at 2 years was 192.5 ± 5.54 mm. The postoperative UBM image of the sclerotomy site at 8 weeks demonstrated a clear wound without any vitreous adhesion or incarceration. Intraoperative hyphema was seen in 1 (2.8% case and postoperative uveitis was seen in 2 (5.7% cases, which resolved with medications. No case of an iatrogenic retinal break or retinal detachment was reported. Conclusions: PPAV enables a closed chamber approach, allows thorough cleanup of vitreous in the pupillary plane and anterior chamber and affords better access to the subincisional and retropupillary cortical remnant with a significant visual outcome and an acceptable complication rate.

  15. Anterior ethmoid anatomy facilitates dacryocystorhinostomy.

    Science.gov (United States)

    Blaylock, W K; Moore, C A; Linberg, J V

    1990-12-01

    The ethmoid air cell labyrinth lies adjacent to the medial orbital wall, extending even beyond the sutures of the ethmoid bone. Its anatomic relationship to the lacrimal sac fossa is important in lacrimal surgery. We evaluated computed tomographic scans of 190 orbits with normal ethmoid anatomy to define the anatomic relationship of anterior ethmoid air cells to the lacrimal sac fossa. In 93% of the orbits, the cells extended anterior to the posterior lacrimal crest, with 40% entering the frontal process of the maxilla. This anatomic relationship may be used to facilitate the osteotomy during dacryocystorhinostomy. During a 10-year period (310 cases), one of us routinely entered the anterior ethmoid air cells to initiate the osteotomy during dacryocystorhinostomy. This technique has helped to avoid lacerations of the nasal mucosa.

  16. Evaluation of Depth of Field for depth perception in DVR

    KAUST Repository

    Grosset, A.V.Pascal

    2013-02-01

    In this paper we present a user study on the use of Depth of Field for depth perception in Direct Volume Rendering. Direct Volume Rendering with Phong shading and perspective projection is used as the baseline. Depth of Field is then added to see its impact on the correct perception of ordinal depth. Accuracy and response time are used as the metrics to evaluate the usefulness of Depth of Field. The onsite user study has two parts: static and dynamic. Eye tracking is used to monitor the gaze of the subjects. From our results we see that though Depth of Field does not act as a proper depth cue in all conditions, it can be used to reinforce the perception of which feature is in front of the other. The best results (high accuracy & fast response time) for correct perception of ordinal depth occurs when the front feature (out of the two features users were to choose from) is in focus and perspective projection is used. © 2013 IEEE.

  17. Anatomic anterior cruciate ligament reconstruction: reducing anterior tibial subluxation

    NARCIS (Netherlands)

    Muller, Bart; Duerr, Eric R. H.; van Dijk, C. Niek; Fu, Freddie H.

    2016-01-01

    To measure and compare the amount of anterior tibial subluxation (ATS) after anatomic ACL reconstruction for both acute and chronic ACL-deficient patients. Fifty-two patients were clinically and radiographically evaluated after primary, unilateral, anatomic ACL reconstruction. Post-operative true

  18. Scheimpflug image-based changes in anterior segment parameters during accommodation induced by short-term reading.

    Science.gov (United States)

    Lipecz, Agnes; Tsorbatzoglou, Alexis; Hassan, Ziad; Berta, Andras; Modis, Laszlo; Nemeth, Gabor

    2017-05-11

    To analyze the effect of the accommodation on the anterior segment data (corneal and anterior chamber parameters) induced by short-time reading in a healthy, nonpresbyopic adult patient group. Images of both eyes of nonpresbyopic volunteers were captured with a Scheimpflug device (Pentacam HR) in a nonaccommodative state. Fifteen minutes of reading followed and through fixation of the built-in target of Pentacam HR further accommodation was achieved and new images were captured by the device. Anterior segment parameters were observed and the differences were analyzed. Fifty-two healthy eyes of 26 subjects (range 20.04-28.58 years) were analyzed. No significant differences were observed in the keratometric values before and after the accommodative task (p = 0.35). A statistically significant difference was measured in the 5.0-mm-diameter and the 7.0-mm-diameter corneal volume (p = 0.01 and p = 0.03) between accommodation states. Corneal aberrometric data did not change significantly during short-term accommodation. Significant differences were observed between nonaccommodative and accommodative states of the eyes for all measured anterior chamber parameters. Among the parameters of the cornea, only corneal volume changed during the short-term accommodation process, showing some fine changes with accommodation of the cornea in young, emmetropic patients. The position of the pupil and the anterior chamber parameters were observed to change with accommodation as captured by a Scheimpflug device.

  19. Two-chambered right ventricle resulting from aberrant muscle bundles: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Lim, T. H.; Ko, K. H.; Im, C. K.; Han, M. C.; Chi, J. G [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1979-12-15

    The 'Two-chambered right ventricle' is a rare, but unique congenital cardiac anomaly characterized by subdivision of the right ventricle into proximal high pressure chamber and distal low pressure chamber by hypertrophied aberrant muscle bundles. The aberrant muscle bundles traverse the right ventricle from the region of crista supraventricular is to the lower part of the anterior wall of the right ventricle. The ' Two-chambered right ventricle' is usually associated with other congenital cardiac anomalies such as ventricular septal defect, pulmonary valvular stenosis, etc. Therefore this anomaly could be mistakenly diagnosed as Tetralogy of Fallot or isolated interventricular septal defect. The need to separate this entity from other types of infundibular stenosis is emphasized because of the important surgical implications. Authors recently experienced a case of the {sup T}wo-chambered right ventricle' resulting from aberrant muscle bundles, that are associated with other cardiac anomalies i.e., pulmonary valvular stenosis, aysplastic tricuspid valve with regurgitation and partial anomalous pulmonary venous return to the right atrium. Here we present the findings of E.K.G., cardiac catheterization, simple chest pa, cine-right ventriculography, and autopsy together with a review of related articles.

  20. Two-chambered right ventricle resulting from aberrant muscle bundles: a case report

    International Nuclear Information System (INIS)

    Lim, T. H.; Ko, K. H.; Im, C. K.; Han, M. C.; Chi, J. G

    1979-01-01

    The 'Two-chambered right ventricle' is a rare, but unique congenital cardiac anomaly characterized by subdivision of the right ventricle into proximal high pressure chamber and distal low pressure chamber by hypertrophied aberrant muscle bundles. The aberrant muscle bundles traverse the right ventricle from the region of crista supraventricular is to the lower part of the anterior wall of the right ventricle. The ' Two-chambered right ventricle' is usually associated with other congenital cardiac anomalies such as ventricular septal defect, pulmonary valvular stenosis, etc. Therefore this anomaly could be mistakenly diagnosed as Tetralogy of Fallot or isolated interventricular septal defect. The need to separate this entity from other types of infundibular stenosis is emphasized because of the important surgical implications. Authors recently experienced a case of the T wo-chambered right ventricle' resulting from aberrant muscle bundles, that are associated with other cardiac anomalies i.e., pulmonary valvular stenosis, aysplastic tricuspid valve with regurgitation and partial anomalous pulmonary venous return to the right atrium. Here we present the findings of E.K.G., cardiac catheterization, simple chest pa, cine-right ventriculography, and autopsy together with a review of related articles.

  1. USE OF GROWTH CHAMBERS FOR CABBAGE BREEDING

    Directory of Open Access Journals (Sweden)

    L. L. Bondareva

    2014-01-01

    Full Text Available Use of the growth chambers for cabbage breeding allows the reducing of certain stages of the breeding process and the growing biennial varieties of cabbage in a one-year cycle. In these growth chambers, the nutritional conditions, temperature, and lighting of plants are under control; the open pollination is eliminated.

  2. HVAC&R Equipment Environmental Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — Description:Large "Truck" ChamberThe large "truck" chamber provides controlled air conditions from -7 °C (20 °F) to 65 °C (150 °F).Air-Conditioner and Heat Pump Test...

  3. 21 CFR 866.2120 - Anaerobic chamber.

    Science.gov (United States)

    2010-04-01

    ... and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2120 Anaerobic chamber. (a) Identification. An anaerobic chamber is a device intended for medical purposes to maintain an anaerobic (oxygen...

  4. Wide-band antennas for reverberation chambers

    NARCIS (Netherlands)

    Vogt-Ardatjew, R.A.; van de Beek, G.S.; Leferink, Frank Bernardus Johannes

    2012-01-01

    Shielding effectiveness measurements in a dual vibrating intrinsic reverberation chamber results in very repeatable results for a large frequency range and large dynamic range. Antennas in reverberation chambers do not need any gain, but the losses should be low and the dimensions should be small.

  5. Shielding Effectiveness Measurements using a Reverberation Chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes; Bergsma, J.G.; Bergsma, Hans; van Etten, Wim

    2006-01-01

    Shielding effectiveness measurements have been performed using a reverberation chamber. The reverberation chamber methodology as we1l as the measurement setup is described and some results are given. Samples include glass reinforced plastic panels, aluminum panels with many holes, wire mesh, among

  6. Resistive wall heating due to image current on the beam chamber for a superconducting undulator.

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. H. (Accelerator Systems Division (APS))

    2012-03-27

    The image-current heating on the resistive beam chamber of a superconducting undulator (SCU) was calculated based on the normal and anomalous skin effects. Using the bulk resistivity of copper for the beam chamber, the heat loads were calculated for the residual resistivity ratios (RRRs) of unity at room temperature to 100 K at a cryogenic temperature as the reference. Then, using the resistivity of the specific aluminum alloy 6053-T5, which will be used for the SCU beam chamber, the heat loads were calculated. An electron beam stored in a storage ring induces an image current on the inner conducting wall, mainly within a skin depth, of the beam chamber. The image current, with opposite charge to the electron beam, travels along the chamber wall in the same direction as the electron beam. The average current in the storage ring consists of a number of bunches. When the pattern of the bunched beam is repeated according to the rf frequency, the beam current may be expressed in terms of a Fourier series. The time structure of the image current is assumed to be the same as that of the beam current. For a given resistivity of the chamber inner wall, the application ofthe normal or anomalous skin effect will depend on the harmonic numbers of the Fourier series of the beam current and the temperature of the chamber. For a round beam chamber with a ratius r, much larger than the beam size, one can assume that the image current density as well as the density square, may be uniform around the perimeter 2{pi}r. For the SCU beam chamber, which has a relatively narrow vertical gap compared to the width, the effective perimeter was estimated since the heat load should be proportional to the inverse of the perimeter.

  7. Compact ion chamber based neutron detector

    Science.gov (United States)

    Derzon, Mark S.; Galambos, Paul C.; Renzi, Ronald F.

    2015-10-27

    A directional neutron detector has an ion chamber formed in a dielectric material; a signal electrode and a ground electrode formed in the ion chamber; a neutron absorbing material filling the ion chamber; readout circuitry which is electrically coupled to the signal and ground electrodes; and a signal processor electrically coupled to the readout circuitry. The ion chamber has a pair of substantially planar electrode surfaces. The chamber pressure of the neutron absorbing material is selected such that the reaction particle ion trail length for neutrons absorbed by the neutron absorbing material is equal to or less than the distance between the electrode surfaces. The signal processor is adapted to determine a path angle for each absorbed neutron based on the rise time of the corresponding pulse in a time-varying detector signal.

  8. Advanced tube-bundle rocket thrust chamber

    Science.gov (United States)

    Kazaroff, John M.; Pavli, Albert J.

    1990-01-01

    An advanced rocket thrust chamber for future space application is described along with an improved method of fabrication. Potential benefits of the concept are improved cyclic life, reusability, and performance. Performance improvements are anticipated because of the enhanced heat transfer into the coolant which will enable higher chamber pressure in expander cycle engines. Cyclic life, reusability and reliability improvements are anticipated because of the enhanced structural compliance inherent in the construction. The method of construction involves the forming of the combustion chamber with a tube-bundle of high conductivity copper or copper alloy tubes, and the bonding of these tubes by an electroforming operation. Further, the method of fabrication reduces chamber complexity by incorporating manifolds, jackets, and structural stiffeners while having the potential for thrust chamber cost and weight reduction.

  9. Multispecimen dual-beam irradiation damage chamber

    International Nuclear Information System (INIS)

    Packan, N.H.; Buhl, R.A.

    1980-06-01

    An irradiation damage chamber that can be used to rapidly simulate fast neutron damage in fission or fusion materials has been designed and constructed. The chamber operates in conjunction with dual Van de Graaff accelerators at ORNL to simulate a wide range of irradiation conditions, including pulsed irradiation. Up to six experiments, each with up to nine 3-mm disk specimens, can be loaded into the ultrahigh vacuum chamber. Specimen holders are heated with individual electron guns, and the temperature of each specimen can be monitored during bombardment by an infrared pyrometer. Three different dose levels may be obtained during any single bombardment, and the heavy-ion flux on each of the nine specimens can be measured independently with only a brief interruption of the beam. The chamber has been in service for nearly three years, during which time approximately 250 bombardments have been successfully carried out. An appendix contains detailed procedures for operating the chamber

  10. Monte Carlo Simulation in the Optimization of a Free-Air Ionization Chamber for Dosimetric Control in Medical Digital Radiography

    International Nuclear Information System (INIS)

    Leyva, A.; Pinera, I.; Abreu, Y.; Cruz, C. M.; Montano, L. M.

    2008-01-01

    During the earliest tests of a free-air ionization chamber a poor response to the X-rays emitted by several sources was observed. Then, the Monte Carlo simulation of X-rays transport in matter was employed in order to evaluate chamber behavior as X-rays detector. The photons energy deposition dependence with depth and its integral value in all active volume were calculated. The obtained results reveal that the designed device geometry is feasible to be optimized

  11. Fracture of the anterior colliculus.

    Science.gov (United States)

    Skie, M C; Ebraheim, N A; Woldenberg, L; Randall, K

    1995-04-01

    The authors retrospectively reviewed 33 cases of fracture involving the anterior colliculus of the medial malleolus to examine clinical results of operative treatment for these fractures. Although this injury appears innocuous, it can be difficult to obtain stable fixation of the fragment intraoperatively, and painful nonunion can result. A simple reduction maneuver and method of tension band fixation are described.

  12. [Indications for and limitations of low anterior resection].

    Science.gov (United States)

    Maeda, K; Maruta, M; Utsumi, T; Sato, H; Matsumoto, M

    2000-06-01

    The indications for low anterior resection are based mainly on tumor location, penetration depth, histology, macroscopic appearance, etc. Patients with tumors located 2 cm above the puborectal muscle by digital examination can undergo low anterior resection. Distal surgical margins should be at least 1 cm from the tumor in cases of differentiated cancer and localized tumors of stage T2 or less and more than 2 cm in poorly differentiated cancer and tumors of stage T3 or greater with total mesorectal excision (TME). Longer distal surgical margins should be provided in patients with unlocalized tumors and extensive node metastasis. The final decision on whether low anterior resection is appropriate should be made after mesorectal preparation down to the levator muscles with adequate surgical margins. Low anterior resection is contraindicated in patients with poor anorectal function and high age. A rectal stump 1 to 2 cm from the dentate line should be maintained for better postoperative anorectal function if radical excision can still be performed.

  13. Válvula de uretra anterior Anterior urethral valves

    Directory of Open Access Journals (Sweden)

    Silvio Tucci Jr.

    2003-02-01

    Full Text Available Objetivo: apresentar os aspectos clínicos, diagnósticos e terapêuticos de pacientes portadores de válvula da uretra anterior. Descrição: em dois neonatos, o diagnóstico presuntivo de patologia obstrutiva do trato urinário foi sugerido pela ultra-sonografia realizada no período pré-natal, confirmando-se o diagnóstico de válvula de uretra anterior pela avaliação pós-natal. Os pacientes foram submetidos a tratamento cirúrgico paliativo, com vesicostomia temporária e, posteriormente, definitivo, pela fulguração endoscópica das válvulas. Ambos evoluíram com função renal normal. Comentários: a válvula da uretra anterior é anomalia rara que deve ser considerada em meninos com quadro radiológico pré-natal sugestivo de obstrução infravesical, secundariamente à hipótese mais comum de válvula da uretra posterior. Ressaltamos a utilização da vesicostomia como derivação urinária temporária nestes casos, prevenindo potenciais complicações pela manipulação da uretra do recém-nascido.Objective: to discuss clinical signs, diagnostic tools and therapeutics of anterior urethral valves, an obstructive anomaly of the urinary system in males. Description: signs of urinary tract obstruction were identified on pre-natal ultrasound in two male fetuses and the diagnosis of anterior urethral valves was made through post-natal evaluation. As an initial treatment, vesicostomy was performed in both patients. Later, the valves were fulgurated using an endoscopic procedure. During the follow-up period both patients presented normal renal function. Comments: anterior urethral valves are a rare form of urethral anomaly that must be ruled out in boys with pre-natal ultrasound indicating infravesical obstruction. Vesicostomy used as an initial treatment rather than transurethral fulguration may prevent potential complications that can occur due to the small size of the neonatal urethra.

  14. Analyses of superficial and depth doses in intraoral radiology

    Energy Technology Data Exchange (ETDEWEB)

    Silva Santos de Oliveira, C.; Morais, R.P. de; Nascimento Souza, D. do [Universidade Federal de Sergipe - CCET - Dept. de Fisica, Sao Cristovao, SE (Brazil)

    2006-07-01

    In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film packet holder. The evaluation of the depth doses in the intraoral tissue was obtained using different acrylic plate thickness. The air kerma values have been evaluated with the ionization chamber located in the dental cone exit of the x-rays equipments. The integrated areas of the thermoluminescent glow curves showed coherent values when compared to the ones obtained with the ionization chamber and both methods presented a linear dependence with the exposition time. The analyses with films have allowed the evaluation of the beam scattering in the simulator apparatus. The studies had proven that the analysis of superficial dose and in depth used in dental radiology can be carried with thermoluminescent dosimeters. (authors)

  15. Analyses of superficial and depth doses in intraoral radiology

    International Nuclear Information System (INIS)

    Silva Santos de Oliveira, C.; Morais, R.P. de; Nascimento Souza, D. do

    2006-01-01

    In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO 4 :Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film packet holder. The evaluation of the depth doses in the intraoral tissue was obtained using different acrylic plate thickness. The air kerma values have been evaluated with the ionization chamber located in the dental cone exit of the x-rays equipments. The integrated areas of the thermoluminescent glow curves showed coherent values when compared to the ones obtained with the ionization chamber and both methods presented a linear dependence with the exposition time. The analyses with films have allowed the evaluation of the beam scattering in the simulator apparatus. The studies had proven that the analysis of superficial dose and in depth used in dental radiology can be carried with thermoluminescent dosimeters. (authors)

  16. Repeatability and agreement of five imaging systems for measuring anterior segment parameters in healthy eyes

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar

    2017-01-01

    Full Text Available Purpose: The purpose of this study is to assess the repeatability and agreement of five imaging devices, namely, the Pentacam (Oculus, Sirius (CSO, Orbscan IIz (Bausch and Lomb, Corvis (Oculus, and ultrasound pachymetry (UP, Tomey in measuring steep keratometry (sKm, flat keratometry (fKm, central corneal thickness (CCT, thinnest corneal thickness (TCT, and anterior chamber depth (ACD in healthy individuals. Design: This was prospective, comparative study. Subjects: Forty-six healthy Indian patients. Materials and Methods: Forty-six eyes of 46 healthy participants underwent three consecutive scans on each device by a single examiner. Within-subject standard deviation, test–retest repeatability (TRT, and coefficient of variation (COV for assessing repeatability and Bland–Altman plots for the agreement between the mean measurements of each machine were analyzed. Main Outcome Measures: The repeatability and agreement between the five devices for the measurements of sKm, fKm, CCT, TCT, and ACD. Results: The TRT of sKm measurements ranged between 0.23 diopter (D (with Pentacam and 0.83 D (with Orbscan. The same of fKm, TCT, ACD, and CCT measurements ranged between 0.28 D (with Pentacam and 0.74 D (with Sirius, 7.78 μm (Sirius and 19.81 μm (Orbscan, 0.05 mm (Orbscan and 0.07 (Sirius, and 7.36 μm (Sirius and 18.02 μm (Orbscan, respectively. The TRT of sKm and fKm measurements with Pentacam was significantly lower than those with Orbscan and Sirius. The TRT of TCT measurement with Sirius was significantly lower than that with Pentacam (4.53 μm and Orbscan (7.15 μm. There were statistically significant differences in the mean measurements of all parameters between the devices. The 95% limit of agreement on the Bland–Altman analysis was wide for the measurement pairs with all the devices. Significant proportional bias in the agreement was detected for TCT measurements with all the device pairs and for the ACD measurements between Sirius and

  17. On evaluation of depth accuracy in consumer depth sensors

    Science.gov (United States)

    Abd Aziz, Azim Zaliha; Wei, Hong; Ferryman, James

    2015-12-01

    This paper presents an experimental study of different depth sensors. The aim is to answer the question, whether these sensors give accurate data for general depth image analysis. The study examines the depth accuracy between three popularly used depth sensors; ASUS Xtion Prolive, Kinect Xbox 360 and Kinect for Windows v2. The main attention is to study on the stability of pixels in the depth image captured at several different sensor-object distances by measuring the depth returned by the sensors within specified time intervals. The experimental results show that the fluctuation (mm) of the random selected pixels within the target area, increases with increasing distance to the sensor, especially on the Kinect for Xbox 360 and the Asus Xtion Prolive. Both of these sensors provide pixels fluctuation between 20mm and 30mm at a sensor-object distance beyond 1500mm. However, the pixel's stability of the Kinect for Windows v2 not affected much with the distance between the sensor and the object. The maximum fluctuation for all the selected pixels of Kinect for Windows v2 is approximately 5mm at sensor-object distance of between 800mm and 3000mm. Therefore, in the optimal distance, the best stability achieved.

  18. Small-Field Dosimetry in A 6 MV Photon Beam Using Alanine and Liquid Ionisation Chamber

    DEFF Research Database (Denmark)

    Zimmermann, S.; Riis, H. L.; Hjelm-Hansen, M.

    2012-01-01

    Purpose/Objective: Dosimetry of small field sizes in MV photon beams is an increasingly important subject, and a generally accepted guideline for clinical measurements is still lacking. The present comparative study was carried out to further investigate the use of alanine and the PTW microLion...... of each field and depth. This dose maximum was measured for each field using a Scanditronix Wellhöfer photon field diode. The same measurements were carried out using a liquid ionchamber, PTW microLion, irradiated by 500 MU. The output of the accelerator was controlled by a PTW semiflex ion chamber...

  19. Comparison among different CT ionization chambers

    International Nuclear Information System (INIS)

    Castro, Maysa C. de; Xavier, Marcos; Caldas, Linda V.E.

    2015-01-01

    The dosimetry in computed tomography (CT) is carried out by the use of a pencil type ionization-chamber, because it has a uniform response at all angles relative to the incident beam of radiation, which is essential for CT equipment since the X-ray tube executes a circular movement around the table during irradiation. The commercial ionization chamber used to perform quality control procedures of this kind of equipment has a length of the sensitive volume of 10 cm. In the Calibration Laboratory of Instruments (LCI) of the IPEN there were already developed some prototypes with small differences in construction, when compared to commercially available ionization chambers. They have been used in previous studies and showed results within internationally acceptable limits. The ionization chambers tested in this study present the sensitive volume lengths of 1 cm, 3 cm and 10 cm. The objective of this study was to present results on the stability test of the three homemade ionization chambers and a commercial chamber, as well to obtain the calibration coefficients for each of them in CT standard X radiation beams. The obtained results for both characterization tests are within the recommended limits, except for the homemade ionization chambers with sensitive volume lengths of 3 cm and 1 cm in the case of the stability test. (author)

  20. Monitored Drift Chambers in the ATLAS Detector

    CERN Multimedia

    Herten, G

    Monitored Drift Chambers (MDT) are used in the ATLAS Detector to measure the momentum of high energy muons. They consist of drift tubes, which are filled with an Ar-CO2 gas mixture at 3 bar gas pressure. About 1200 drift chambers are required for ATLAS. They are up to 6 m long. Nevertheless the position of every wire needs to be known with a precision of 20 µm within a chamber. In addition, optical alignment sensors are required to measure the relative position of adjacent chambers with a precision of 30µm. This gigantic task seems impossible at first instance. Indeed it took many years of R&D to invent the right tools and methods before the first chamber could be built according to specifications. Today, at the time when 50% of the chambers have been produced, we are confident that the goal for ATLAS can be reached. The mechanical precision of the chambers could be verified with the x-ray tomograph at CERN. This ingenious device, developed for the MDT system, is able to measure the wire position insid...

  1. Polymerase chain reaction in unilateral cases of presumed viral anterior uveitis.

    Science.gov (United States)

    Shoughy, Samir S; Alkatan, Hind M; Al-Abdullah, Abdulelah A; El-Khani, Albarah; de Groot-Mijnes, Jolanda Df; Tabbara, Khalid F

    2015-01-01

    Anterior uveitis is the most common form of intraocular inflammation. The main aim of this study was to determine the viral etiology in patients with unilateral cases of anterior uveitis. A total of 12 consecutive patients with the diagnosis of idiopathic unilateral anterior uveitis were included prospectively. Aqueous specimens were obtained from each patient by anterior chamber paracentesis and subjected to the detection of viral DNA/RNA genome by polymerase chain reaction assay for herpes simplex virus, varicella zoster virus, cytomegalovirus, Epstein-Barr virus, and rubella virus. There were six male and six female patients. The mean age was 43 years, with an age range of 11-82 years. All 12 cases presented with unilateral anterior uveitis. In four (33%) patients, polymerase chain reaction was positive for viral genome. Two patients were positive for herpes simplex virus type 1, one patient was positive for cytomegalovirus and one for Epstein-Barr virus. Recent molecular diagnostic assays would help in the identification of the causative agent in patients with unilateral anterior uveitis.

  2. Making MUSIC: A multiple sampling ionization chamber

    International Nuclear Information System (INIS)

    Shumard, B.; Henderson, D.J.; Rehm, K.E.; Tang, X.D.

    2007-01-01

    A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the (α, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for (α, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only (α, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. x 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the (α, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the (α, p) reaction to reach the anode segment below the reaction

  3. Making MUSIC: A multiple sampling ionization chamber

    Energy Technology Data Exchange (ETDEWEB)

    Shumard, B. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States)]. E-mail: shumard@phy.anl.gov; Henderson, D.J. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States); Rehm, K.E. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States); Tang, X.D. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States)

    2007-08-15

    A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the ({alpha}, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for ({alpha}, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only ({alpha}, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. x 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the ({alpha}, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the ({alpha}, p) reaction to reach the anode segment below the reaction.

  4. Anterior cruciate ligament (ACL) injury -- aftercare

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000681.htm Anterior cruciate ligament (ACL) injury - aftercare To use the sharing features ... that connects a bone to another bone. The anterior cruciate ligament (ACL) is located inside your knee joint and ...

  5. Weld Development for Aluminum Fission Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Cross, Carl Edward [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Martinez, Jesse Norris [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-16

    The Sigma welding team was approached to help fabricate a small fission chamber (roughly ½ inch dia. x ½ inch tall cylinder). These chambers are used as radiation sensors that contain small traces of radionuclides (Cf 252, U 235, and U 238) that serve to ionize gas atoms in addition to external radiation. When a voltage is applied within the chamber, the resulting ion flow can be calibrated and monitored. Aluminum has the advantage of not forming radioactive compounds when exposed to high external radiation (except from minor Na alloy content). Since aluminum has not been used before in this application, this presented an unexplored challenge.

  6. LEP vacuum chamber, cross-section

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    Cross-section of the final prototype for the LEP vacuum chamber. The elliptic main-opening is for the beam. The small channel to the left is for the cooling water, to carry away the heat deposited by the synchrotron radiation. The square channel to the right houses the Non-Evaporable Getter (NEG) pump. The chamber is made from extruded aluminium. Its outside is clad with lead, to stop the synchrotron radiation emitted by the beam. For good adherence between Pb and Al, the Al chamber was coated with a thin layer of Ni. Ni being slightly magnetic, some resulting problems had to be overcome. See also 8301153.

  7. Bubble chamber: Omega production and decay

    CERN Multimedia

    1973-01-01

    This image is of real particle tracks taken from the CERN 2 m liquid hydrogen bubble chamber and shows the production and decay of a negative omega particle. A negative kaon enters the chamber which decays into many particles, including a negative omega that travels a short distance before decaying into more particles. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that had been heated to boiling point.

  8. Cloud chamber photographs of the cosmic radiation

    CERN Document Server

    Rochester, George Dixon

    1952-01-01

    Cloud Chamber Photographs of the Cosmic Radiation focuses on cloud chamber and photographic emulsion wherein the tracks of individual subatomic particles of high energy are studied. The publication first offers information on the technical features of operation and electrons and cascade showers. Discussions focus on the relationship in time and space of counter-controlled tracks; techniques of internal control of the cloud chamber; cascade processes with artificially-produced electrons and photons; and nuclear interaction associated with an extensive shower. The manuscript then elaborates on

  9. APS Storage Ring vacuum chamber fabrication

    International Nuclear Information System (INIS)

    Goeppner, G.A.

    1990-01-01

    The 1104-m circumference Advanced Photon Source Storage Ring Vacuum System is composed of 240 individual sections, which are fabricated from a combination of aluminum extrusions and machined components. The vacuum chambers will have 3800 weld joints, each subject to strict vacuum requirements, as well as a variety of related design criteria. The vacuum criteria and chamber design are reviewed, including a discussion of the weld joint geometries. The critical fabrication process parameters for meeting the design requirements are discussed. The experiences of the prototype chamber fabrication program are presented. Finally, the required facilities preparation for construction activity is briefly described. 6 refs., 6 figs., 1 tab

  10. Dilution refrigeration with multiple mixing chambers

    International Nuclear Information System (INIS)

    Coops, G.M.

    1981-01-01

    A dilution refrigerator is an instrument to reach temperatures in the mK region in a continuous way. The temperature range can be extended and the cooling power can be enlarged by adding an extra mixing chamber. In this way we obtain a double mixing chamber system. In this thesis the theory of the multiple mixing chamber is presented and tested on its validity by comparison with the measurements. Measurements on a dilution refrigerator with a circulation rate up to 2.5 mmol/s are also reported. (Auth.)

  11. Anterior spinal cord syndrome of unknown etiology

    OpenAIRE

    Klakeel, Merrine; Thompson, Justin; Srinivasan, Rajashree; McDonald, Frank

    2015-01-01

    A spinal cord injury encompasses a physical insult to the spinal cord. In the case of anterior spinal cord syndrome, the insult is a vascular lesion at the anterior spinal artery. We present the cases of two 13-year-old boys with anterior spinal cord syndrome, along with a review of the anatomy and vasculature of the spinal cord and an explanation of how a lesion in the cord corresponds to anterior spinal cord syndrome.

  12. ISLSCP II Ecosystem Rooting Depths

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of this study was to predict the global distribution of plant rooting depths based on data about global aboveground vegetation structure and climate....

  13. ISLSCP II Ecosystem Rooting Depths

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: The goal of this study was to predict the global distribution of plant rooting depths based on data about global aboveground vegetation structure and...

  14. Development of Cold Neutron Depth Profiling System at HANARO

    International Nuclear Information System (INIS)

    Park, B. G.; Choi, H. D.; Sun, G. M.

    2012-01-01

    The depth profiles of intentional or intrinsic constituents of a sample provide valuable information for the characterization of materials. A number of analytical techniques for depth profiling have been developed. Neutron Depth Profiling (NDP) system which was developed by Ziegler et al. is one of the leading analytical techniques. In NDP, a thermal or cold neutron beam passes through a material and interacts with certain isotopes that are known to emit monoenergetic-charged particle remaining a recoil nucleus after neutron absorption. The depth is obtained from the energy loss of those charged particles escaping surface of substrate material. For various applications of NDP technique, the Cold Neutron Depth Profiling System (CN-NDP) was developed at a neutron guide CG1 installed at the HANARO cold neutron source. In this study the design features of the cold neutron beam and target chamber for the CN-NDP system are given. Also, some experiments for the performance tests of the CN-NDP system are described

  15. 38 CFR 3.379 - Anterior poliomyelitis.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Anterior poliomyelitis. 3... Specific Diseases § 3.379 Anterior poliomyelitis. If the first manifestations of acute anterior poliomyelitis present themselves in a veteran within 35 days of termination of active military service, it is...

  16. Epidermoid cyst in Anterior, Middle

    Directory of Open Access Journals (Sweden)

    Kankane Vivek Kumar

    2016-09-01

    Full Text Available Epidermoid cysts are benign slow growing more often extra-axial tumors that insinuate between brain structures, we present the clinical, imaging, and pathological findings in 35 years old female patients with atypical epidermoid cysts which was situated anterior, middle & posterior cranial fossa. NCCT head revealed hypodense lesion over right temporal and perisylvian region with extension in prepontine cistern with mass effect & midline shift and MRI findings revealed a non-enhancing heterogeneous signal intensity cystic lesion in right frontal & temporal region extending into prepontine cistern with restricted diffusion. Patient was detoriated in night of same day of admission, emergency Fronto-temporal craniotomy with anterior peterousectomy and subtotal resection was done. The histological examination confirms the epidermoid cyst. The timing of ectodermal tissue sequestration during fetal development may account for the occurrence of atypical epidermoid cysts.

  17. [Anterior chest wall examination reviewed].

    Science.gov (United States)

    Lo Monaco, A; Santilli, D; Trotta, F

    2002-01-01

    Anterior chest wall involvement is not infrequently observed within inflammatory arthropaties, particularly if one considers seronegative spondyloarthritides and SAPHO syndrome. Physical examination is unreliable and conventional X-rays analysis is an unsatisfactory tool during diagnostic work-up of this region. Scintigraphic techniques yield informations both on the activity and on the anatomical extent of the disease while computerized tomography visualize the elementary lesions, such as erosions, which characterize the process. Moreover, when available, magnetic resonance imaging couple the ability to finely visualize such lesions with the possibility to show early alterations and to characterize the "activity" of the disease, presenting itself as a powerful tool both for diagnosis and follow-up. This review briefly shows the applications of imaging techniques for the evaluation of the anterior chest wall focusing on what has been done in the SAPHO syndrome which can be considered prototypical for this regional involvement since it is the osteo-articular target mainly affected by the disease.

  18. Chronic Anterior Uveitis in Children.

    Science.gov (United States)

    Couto, Cristóbal; Frick, Mercedes M; LaMattina, Kara; Schlaen, Ariel; Khoury, Marina; Lopez, Matilde María; Hurtado, Erika; Espada, Graciela

    2016-08-01

    To describe the visual prognosis and remission rate of chronic anterior uveitis in pediatric patients. A retrospective case series of children with chronic anterior uveitis treated in the University of Buenos Aires. Juvenile idiopathic arthritis was defined according to the International League of Associations for Rheumatology criteria. Uveitis remission was defined according to SUN criteria. There were 35 pediatric patients (61 eyes), mean age of uveitis onset was 7.69 ± 3 years, 60% were females and 74% had bilateral disease, median follow-up was 60 months (range: 12-192 months). JIA was more frequent in females (80.95 vs 21.43; pgood Received 30 August 2015; revised 6 March 2016; accepted 14 March 2016; published online 18 May 2016.

  19. High-pressure gas chamber for neutron diffraction studies

    International Nuclear Information System (INIS)

    Stepanov, G. N.; Telepnev, A. S.; Simkin, V. G.

    2007-01-01

    The construction of a chamber designed for neutron diffraction studies of the structure of solids under high gas pressures up to 0.5 GPa is described. This chamber is a modification of the chamber published earlier

  20. Simulated Field Trials Using an Indoor Aerosol Test Chamber

    National Research Council Canada - National Science Library

    Semler, D. D; Roth, A. P; Semler, K. A; Nolan, P. M

    2004-01-01

    .... In this method, the aerosol chamber control software manipulates circulation fan speeds, chamber vacuum and agent spray times to produce a simulated dynamic cloud within the aerosol test chamber...

  1. Simulated Field Trials Using An Indoor Aerosol Test Chamber

    National Research Council Canada - National Science Library

    Semler, D. D; Roth, A. P; Semler, K. A; Nolan, P. M

    2004-01-01

    .... In this method, the aerosol chamber control software manipulates circulation fan speeds, chamber vacuum and agent spray times to produce a simulated dynamic cloud within the aerosol test chamber...

  2. A magma chamber model beneath Unzen Volcano inferred from geodetic and seismic data using FEM

    Science.gov (United States)

    Kohno, Y.; Matsumoto, S.; Matsushima, T.; Uehira, K.; Umakoshi, K.; Shimizu, H.

    2008-12-01

    A supplying system of the magma beneath Unzen volcano has been proposed using both geodetic and seismic data simultaneously. Spatial variation of geodetic data is affected by change of magma body in both of shape and pressure. In most cases, relative stress field is able to be inferred from focal mechanisms of earthquakes. This changing also disturbs stress field in the region around the magma chamber. A model about shape and internal pressure of magma chamber is constrained by mean of both grounds deformation and focal mechanism. Unzen Volcano is the massive volcanic complex, located in the middle part of Kyushu Island, Japan, erupted accompanying by pyroclastic flows and formed a huge lava dome at the summit during 1990-1995. Based on geodetic data during period 1991-2004, a magma chamber model composed of four pressure sources was constructed by grid search method (Kohno et al., 2008). For the data with greater crustal deformation observed in 1992-93 and 1993-94, we applied finite element method (FEM) to model the magma chamber. Especially, shape of a pressure source at a depth of 7 km (C-source) was also estimated in this searching process. C-source during 1992-93 has an oblate spheroid with south-southwest dip oriented made good correlation with observation data. Regards only from ground deformation data, the length of the major axis is smaller than 3km. The shape sustains to an idea that magma ascends easily toward the shallower chamber. The best solution of C-source in 1993-94 was obtained as a prolate spheroid source with north dip oriented. This latter source is smaller size and dipping to opposite side with the previous one. Although they are separated at distance of 1 km, this is not far to call different magma chamber each other. Different shape indicated that inhomogeneous structure of magma chamber. From this arrangement of the sources, we considered a model that the magma chamber at a depth of about 7 km could be composed of small magma chambers like

  3. Utilising Geological Field Measurements and Historic Eruption Volumes to Estimate the Volume of Santorini's Magma Chamber

    Science.gov (United States)

    Browning, J.; Drymoni, K.; Gudmundsson, A.

    2015-12-01

    An understanding of the amount of magma available to supply any given eruption is useful for determining the potential eruption magnitude and duration. Geodetic measurements and inversion techniques are often used to constrain volume changes within magma chambers, as well as constrain location and depth, but such models are incapable of calculating total magma storage. For example, during the 2012 unrest period at Santorini volcano, approximately 0.021 km3 of new magma entered a shallow chamber residing at around 4 km below the surface. This type of event is not unusual, and is in fact a necessary condition for the formation of a long-lived shallow chamber, of which Santorini must possess. The period of unrest ended without culminating in eruption, i.e the amount of magma which entered the chamber was insufficient to break the chamber and force magma further towards the surface. We combine previously published data on the volume of recent eruptions at Santorini together with geodetic measurements. Measurements of dykes within the caldera wall provide an estimate of the volume of magma transported during eruptions, assuming the dyke does not become arrested. When the combined volume of a dyke and eruption are known (Ve) they can be used to estimate using fracture mechanics principles and poro-elastic constraints the size of an underlying shallow magma chamber. We present field measurements of dykes within Santorini caldera and provide an analytical method to estimate the volume of magma contained underneath Santorini caldera. In addition we postulate the potential volume of magma required as input from deeper sources to switch the shallow magma chamber from an equilibrium setting to one where the pressure inside the chamber exceeds the surrounding host rocks tensile strength, a condition necessary to form a dyke and a possible eruption.

  4. Anterior cingulotomy for intractable pain

    Directory of Open Access Journals (Sweden)

    Nitin Agarwal, MD

    2016-12-01

    Full Text Available Conservative therapy is often the first-line treatment for many symptoms of various disease processes, including pain. Nevertheless, if pharmacological or medical management fails for those patients with severe and chronic pain, a surgical strategy may be a reasonable option. First performed for psychiatric disorders, cingulotomy now has been recognized as a viable option for the management of pain. The authors review the literature on anterior cingulotomy for intractable pain to provide guidelines for management and expected outcomes.

  5. Anterior shoulder dislocations in sports.

    Science.gov (United States)

    Aronen, J G

    1986-01-01

    Anterior shoulder dislocations, primary and recurrent, are among the most disabling injuries to the shoulder that can plague the athlete. The diagnosis is easily made by the following: the physical appearance of the shoulder; loss of capability by the athlete to internally and externally rotate the shoulder with the elbow at his side; by evaluating the mechanism of injury; and x-rays. Anterior shoulder dislocations should be reduced as soon as possible after diagnosis, to minimise the stretching effect on the neurovascular structures while the humeral head is dislocated. The reduction is not done to allow the athlete to return immediately to sport. Use of a simple traction method in the first 10 to 15 minutes following the injury will result in a successful reduction in the vast majority of dislocations. Reduction of the humeral head can be confirmed by the athlete regaining the capability to internally and externally rotate his shoulder with his elbow at his side. Following reduction, the athlete should begin a treatment regimen which includes a restrengthening programme emphasising the muscles of internal rotation and adduction plus rigid restrictions of activities until the goals of the rehabilitation programme are satisfied. The author's experience with this treatment regimen with athletes at the United States Naval Academy, has shown a decrease of the recurrence rate of primary anterior shoulder dislocations to 25% versus the 80% recurrence rate we have become familiar with from studies done which did not stress specific rehabilitation programmes. The athlete should also be instructed in a self-performed traction method for reduction should a redislocation occur, to minimise the stretching effect on the neurovascular structures and allow relief from discomfort. Surgery for primary and recurrent anterior dislocations should only be considered when the athlete fails to achieve the desired goals after participating in a specific, progressive, adequate

  6. Anterior chest wall examination reviewed

    OpenAIRE

    F. Trotta; D. Santilli; A. Lo Monaco

    2011-01-01

    Anterior chest wall involvement is not infrequently observed within inflammatory arthropaties, particularly if one considers seronegative spondiloarthritides and SAPHO syndrome. Physical examination is unreliable and conventional X-rays analysis is an unsatisfactory tool during diagnostic work-up of this region. Scintigraphic techniques yield informations both on the activity and on the anatomical extent of the disease while computerized tomography visualize the elementary lesions, such as er...

  7. Effect of coronary occlusion during percutaneous transluminal angioplasty in humans on left ventricular chamber stiffness and regional diastolic pressure-radius relations

    NARCIS (Netherlands)

    W. Wijns (William); P.W.J.C. Serruys (Patrick); C.J. Slager (Cornelis); J. Grimm; H.P. Krayenbuehl; P.G. Hugenholtz (Paul); O.M. Hess (Otto)

    1986-01-01

    textabstractThe effect of repeated (3 to 10 second) and transient (15 to 75 second) abrupt coronary occlusion on the global and regional chamber stiffness was studied in nine patients undergoing angioplasty of a single proximal left anterior descending coronary artery stenosis. The left ventricular

  8. Cloud chamber development for didactic use

    International Nuclear Information System (INIS)

    Straube, B; Carrillo, M; Mangussi J

    2012-01-01

    The goal of this project was the design and construction of an Expansion Cloud Chamber from daily use material in order to make visible during a lesson, the trajectories of particles emitted by a radioactive material (author)

  9. Liquid ionization chambers for LET determination

    DEFF Research Database (Denmark)

    Kaiser, Franz-Joachim; Bassler, Niels; Tölli, Heikki

    Liquid ionization chambers [1] (LICs) have have been used in the last decades as background dosemeters. Since a few years LICs are also commercially available for dosimetry and are used for measurements of dose distributions where a high spatial distribution is necessary. Also in the last decades...... a differential equation applying several simplifications and approximations leading to discrepancies between theory and experiments [3]. The theory predicts the collection efficiency as a function of the electrical field and was applied for both air filled ionization chambers and liquid filled ionization...... chambers. For liquids the LET can be roughly deduced from the collection efficiency dependency on the electrical field inside a liquid ionization chambers [4] using an extrapolation method. We solved the fundamental differential equation again presented by Jaffe numerically, but now taking into account...

  10. RADAR Anechoic Chamber/RCS Measurements Lab

    Data.gov (United States)

    Federal Laboratory Consortium — The RF Anechoic Chamber is 56 feet long by 12 feet high by 13.5 feet wide, with an adjoining electronic computer control room. A double door entrance at one end of...

  11. MAN-IN-SIMULANT TEST (MIST) CHAMBER

    Data.gov (United States)

    Federal Laboratory Consortium — The MIST chamber uses methyl salicylate (oil of wintergreen) vapor as a simulant for HD agent to conduct system level evaluations of chemical protective ensembles....

  12. Uranium deposits obtention for fission chambers

    International Nuclear Information System (INIS)

    Artacho Saviron, E.

    1972-01-01

    The obtention of uranium deposits of the required quality for small cylindrical fission chambers presents some difficulties. With the method of electroplating here described the uniformity, reproducibility and adherence of the obtained deposits were satisfactory. (Author) 6 refs

  13. Three dimensional thrust chamber life prediction

    Science.gov (United States)

    Armstrong, W. H.; Brogren, E. W.

    1976-01-01

    A study was performed to analytically determine the cyclic thermomechanical behavior and fatigue life of three configurations of a Plug Nozzle Thrust Chamber. This thrust chamber is a test model which represents the current trend in nozzle design calling for high performance coupled with weight and volume limitations as well as extended life for reusability. The study involved the use of different materials and material combinations to evaluate their application to the problem of low-cycle fatigue in the thrust chamber. The thermal and structural analyses were carried out on a three-dimensional basis. Results are presented which show plots of continuous temperature histories and temperature distributions at selected times during the operating cycle of the thrust chamber. Computed structural data show critical regions for low-cycle fatigue and the histories of strain within the regions for each operation cycle.

  14. A liquid ionization chamber using tetramethylsilane

    International Nuclear Information System (INIS)

    Engler, J.; Keim, H.

    1983-12-01

    First results with a liquid ionization chamber using tetramethylsilane (TMS) are presented. A stack of iron plates was tested with cosmic ray muons and the charge output for minimum ionizing particles was measured. (orig.) [de

  15. HYLIFE-II reactor chamber design refinements

    International Nuclear Information System (INIS)

    House, P.A.

    1994-06-01

    Mechanical design features of the reactor chamber for the HYLIFE-II inertial confinement fusion power plant are presented. A combination of oscillating and steady, molten salt streams (Li 2 BeF 4 ) are used for shielding and blast protection of the chamber walls. The system is designed for a 6 Hz repetition rate. Beam path clearing, between shots, is accomplished with the oscillating flow. The mechanism for generating the oscillating streams is described. A design configuration of the vessel wall allows adequate cooling and provides extra shielding to reduce thermal stresses to tolerable levels. The bottom portion of the reactor chamber is designed to minimize splash back of the high velocity (>12 m/s) salt streams and also recover up to half of the dynamic head. Cost estimates for a 1 GWe and 2 GWe reactor chamber are presented

  16. Air-Assisted Descemet Stripping Automated Endothelial Keratoplasty with Posterior Chamber Fixation of an Aphakic Iris‑Claw Lens

    Directory of Open Access Journals (Sweden)

    Farid Karimian

    2010-01-01

    Full Text Available Endothelial keratoplasty (EK is the most exciting recent development in corneal transplantation. It has experienced surprisingly rapid growth in a very short period of time. One of the indications for EK is pseudophakic bullous keratopathy. However, concomitant intraocular lens (IOL exchange, if indicated, may prove challenging. Some surgeons routinely perform IOL exchange with a scleral-fixated posterior chamber IOL, together with Descemet′s stripping endothelial keratoplasty (DSEK; however, this combined procedure is time-consuming, difficult and fraught with complications. Another option is aphakic Artisan IOL fixation, but this is usually not acceptable because of the increased risk of endothelial cell loss and difficulty in filling the anterior chamber with the air bubble. Herein, we introduce a new technique for IOL exchange with an aphakic Artisan IOL fixated posterior to the iris, combined with DSEK. This surgical technique was designed to preserve anterior segment anatomic features as much as possible.

  17. Radon progeny distribution in cylindrical diffusion chambers

    International Nuclear Information System (INIS)

    Pressyanov, Dobromir S.

    2008-01-01

    An algorithm to model the diffusion of radioactive decay chain atoms is presented. Exact mathematical solutions in cylindrical geometry are given. They are used to obtain expressions for the concentrations of 222 Rn progeny atoms in the volume and deposited on the wall surface in cylindrical diffusion chambers. The dependence of volume fractions of 222 Rn progeny and chamber sensitivity on the coefficient of diffusion of 222 Rn progeny atoms in air is modeled.

  18. The world's largest time projection chamber

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    Peter Glassel, the technical coordinator for the ALICE time projection chamber, is seen sitting inside the detector; the largest in the world at nearly 100 cubic metres. Thousands of wires are connected to read out electronic data produced as particles are created in lead-lead collisions at the centre of the detector. These particles will cause the medium within the time projection chamber to ionise along their tracks allowing the particle paths to be recreated.

  19. Georges Charpak and his multiwire chamber

    CERN Multimedia

    1970-01-01

    In 1968, Georges Charpak developed the 'multiwire proportional chamber', a gas-filled box with a large number of parallel detector wires, each connected to individual amplifiers. Linked to a computer, it could achieve a counting rate a thousand times better than existing techniques - without a camera in sight. From left to right, Georges Charpak, Fabio Sauli and Jean-Claude Santiard working on a multiwire chamber in 1970.

  20. The large cylindrical drift chamber of TASSO

    International Nuclear Information System (INIS)

    Boerner, H.; Fischer, H.M.; Hartmann, H.; Loehr, B.; Wollstadt, M.; Fohrmann, R.; Schmueser, P.; Cassel, D.G.; Koetz, U.; Kowalski, H.

    1980-03-01

    We have built and operated a large cylindrical drift chamber for the TASSO experiment at the DESY storage ring, PETRA. The chamber has a length of 3.5 m, a diameter of 2.5 m, and a total of 2340 drift cells. The cells are arranged in 15 concentric layers such that tracks can be reconstructed in three dimensions. A spatial resolution of 220 μm has been achieved for tracks of normal incidence on the drift cells. (orig.)

  1. Cylindrical geometry for proportional and drift chambers

    International Nuclear Information System (INIS)

    Sadoulet, B.

    1975-06-01

    For experiments performed around storage rings such as e + e - rings or the ISR pp rings, cylindrical wire chambers are very attractive. They surround the beam pipe completely without any dead region in the azimuth, and fit well with the geometry of events where particles are more or less spherically produced. Unfortunately, cylindrical proportional or drift chambers are difficult to make. Problems are discussed and two approaches to fabricating the cathodes are discussed. (WHK)

  2. Status of the KEDR drift chamber

    CERN Document Server

    Baru, S E; Blinov, V E; Groshev, V R; Kolachev, G M; Minakov, G D; Onuchin, A P; Popkov, I N; Savinov, G A; Shamov, A G; Shusharo, A I; Talyshev, A A; Todyshev, K Y; Yushkov, A N

    2002-01-01

    The 1 m long and 1 m outer diameter chamber consists of 42 layers. The chamber is based on a jet type cells with drift distance of 30 mm. The measurements of the spatial and dE/dx resolution were performed with DME gas with the cosmic particles. The resolution averaged over the drift distance is equal to 110 mu m while dE/dx resolution is 8.2%.

  3. Characteristic parameters of drift chambers calculation

    International Nuclear Information System (INIS)

    Duran, I.; Martinez-Laso, L.

    1989-01-01

    We present here the methods we used to analyse the characteristic parameters of drift chambers. The algorithms to calculate the electric potential in any point for any drift chamber geometry are presented. We include the description of the programs used to calculate the electric field, the drift paths, the drift velocity and the drift time. The results and the errors are discussed. (Author) 7 refs

  4. Liquid-filled ionization chamber temperature dependence

    Energy Technology Data Exchange (ETDEWEB)

    Franco, L. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain)]. E-mail: luciaff@usc.es; Gomez, F. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Iglesias, A. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pardo, J. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pazos, A. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pena, J. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Zapata, M. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain)

    2006-05-10

    Temperature and pressure corrections of the read-out signal of ionization chambers have a crucial importance in order to perform high-precision absolute dose measurements. In the present work the temperature and pressure dependences of a sealed liquid isooctane filled ionization chamber (previously developed by the authors) for radiotherapy applications have been studied. We have analyzed the thermal response of the liquid ionization chamber in a {approx}20 deg. C interval around room temperature. The temperature dependence of the signal can be considered linear, with a slope that depends on the chamber collection electric field. For example, a relative signal slope of 0.27x10{sup -2}K{sup -1} for an operation electric field of 1.67x10{sup 6}Vm{sup -1} has been measured in our detector. On the other hand, ambient pressure dependence has been found negligible, as expected for liquid-filled chambers. The thermal dependence of the liquid ionization chamber signal can be parametrized within the Onsager theory on initial recombination. Considering that changes with temperature of the detector response are due to variations in the free ion yield, a parametrization of this dependence has been obtained. There is a good agreement between the experimental data and the theoretical model from the Onsager framework.

  5. Temperature Studies for ATLAS MDT BOS Chambers

    CERN Document Server

    Engl, A.; Biebel, O.; Mameghani, R.; Merkl, D.; Rauscher, F.; Schaile, D.; Ströhmer, R.

    Data sets with high statistics taken at the cosmic ray facility, equipped with 3 ATLAS BOS MDT chambers, in Garching (Munich) have been used to study temperature and pressure effects on gas gain and drifttime. The deformation of a thermally expanded chamber was reconstructed using the internal RasNik alignment monitoring system and the tracks from cosmic data. For these studies a heating system was designed to increase the temperature of the middle chamber by up to 20 Kelvins over room temperature. For comparison the temperature effects on gas properties have been simulated with Garfield. The maximum drifttime decreased under temperature raise by -2.21 +- 0.08 ns/K, in agreement with the results of pressure variations and the Garfield simulation. The increased temperatures led to a linear increase of the gas gain of about 2.1% 1/K. The chamber deformation has been analyzed with the help of reconstructed tracks. By the comparison of the tracks through the reference chambers with these through the test chamber ...

  6. Quality control of ATLAS muon chambers

    CERN Document Server

    Fabich, Adrian

    ATLAS is a general-purpose experiment for the future Large Hadron Collider (LHC) at CERN. Its Muon Spectrometer will require ∼ 5500m2 of precision tracking chambers to measure the muon tracks along a spectrometer arm of 5m to 15m length, embedded in a magnetic field of ∼ 0.5T. The precision tracking devices in the Muon System will be high pressure drift tubes (MDTs). Approximately 370,000 MDTs will be assembled into ∼ 1200 drift chambers. The performance of the MDT chambers is very much dependent on the mechanical quality of the chambers. The uniformity and stability of the performance can only be assured providing very high quality control during production. Gas tightness, high-voltage behaviour and dark currents are global parameters which are common to gas detectors. For all chambers, they will be tested immediately after the chamber assembly at every production site. Functional tests, for example radioactive source scans and cosmic-ray runs, will be performed in order to establish detailed performan...

  7. Anterior lamina cribrosa surface position in idiopathic intracranial hypertension and glaucoma

    DEFF Research Database (Denmark)

    Villarruel, Jenni Martinez; Li, Xiao Q.; Bach-Holm, Daniella

    2017-01-01

    Purpose: To compare the anterior lamina cribrosa (LC) surface position in patients with idiopathic intracranial hypertension (IIH), primary open-angle glaucoma (high-tension glaucoma [HTG] and normal-tension glaucoma [NTG]), and healthy controls using enhanced depth imaging spectral-domain optical...

  8. [Lens exchange for subluxation of posterior chamber lenses implanted in the capsular bag or in the ciliary sulcus].

    Science.gov (United States)

    Stürmer, J

    2013-04-01

    There are an increasing number of patients with decreased vision due to dislocated posterior chamber lenses, with pseudoexfoliation being the main risk factor. Various techniques for refixation of the subluxated posterior chamber IOL have been described. Experience with our technique of IOL-explantation, anterior vitrectomy and implantation of an Artisan anterior chamber lens are presented. In a retrospective study design all lens exchanges with implantation of an Artisan anterior chamber lens performed between 2003 and 2012 are analyzed. The study included 65 eyes of 61 patients (age 79.6 ± 9.2 years: 43-98). The majority of eyes (46/65; 70.8%) had Sundown Syndrome (late in-the-bag intraocular lens dislocation), in 19 eyes the posterior chamber lens was implanted primary or secondary into the ciliary sulcus. In the 46 eyes with Sundown Syndrome cataract surgery with implantation of a posterior chamber lens in the capsular bag was performed 7.4 ± 3.7 (1-22) years before subluxation within the bag. Pseudoexfoliation was the main risk factor in 42/46 (91.2%) of these eyes. A capsular tension ring (CTR) was implanted during cataract surgery in 34/46 (73.9%) eyes. The 34 IOLs with a CTR luxated significantly earlier (p IOLs without a CTR (6.6 ± 3.6 years; median 5.8 vs. 9.4 ± 3.1 years; median 9.2). The average visual gain was 0.2 logMAR in the group of luxated capsular bag lenses and 0.12 logMAR in the group of luxated sulcus lenses. Postoperative IOP decompensation was seen in 17/65 (26.2%) eyes (requiring IOP-lowering surgery in 8 eyes), 7 eyes developed corneal decompensation, 5 eyes had central retinal vein occlusion and one eye developed postoperative endophthalmitis. Lens exchange with implantation of an Artisan anterior chamber lens has become a routine procedure to improve vision in patients with subluxated IOLs. Postoperative IOP decompensation and vascular problems are the major complications. Georg Thieme Verlag KG Stuttgart · New York.

  9. Droplets coalescence at microchannel intersection chambers with different shapes

    Science.gov (United States)

    Liu, Zhaomiao; Wang, Xiang; Cao, Rentuo; Pang, Yan

    2016-11-01

    The influence of microchannel intersection chamber shape on droplets coalescence process is investigated in this study. Three kinds of chamber shapes (half-round, triangle and camber) are designed to realize head-on droplets coalescence. The coalescence processes are visualized with high-speed camera system and the internal flow patterns are resolved with micro-PIV system. Experimental analyses on droplets coalescence position, coalescence time and the critical conditions are discussed. Both direct coalescence and late coalescence can be observed in the camber junction while only the late coalescence is present for the half-round and the triangle junction. The critical capillary number Ca* varies for different working systems or intersection shapes. Ca* in the camber junction is larger than that in the other two junctions for each working system and it decreases with the increase of the viscosity ratios for each intersection shape. Moreover, the characteristics of the velocity fields for different coalescence cases are analyzed for in-depth understanding of the process. The authors do appreciate the financial support of No.11572013 of National Nature Scicence Funding of China.

  10. Results and complications of scleral fixated (Sutured posterior chamber intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Amoozadeh J

    2001-08-01

    Full Text Available Optical rehabilitation of the patient with aphakia who cannot tolerate contact lenses present a therapeutic challenge. In the absence of capsular support, anterior chamber lenses have been widely used. On the other hand intraocular lens implantation of scleral sutured posterior chamber intraocular lens during penterating keratoplasty or insufficient iris support is recommended. The purpose of this study is to evaluate the clinical outcome and complication in 17 patients who underwent scleral-fixation of an intraocular lens.We studied prospectively the results of posterior chamber intraocular lens implantation by scleral fixation in 17 eyes of 17 patients without a complete posterior lens capsule support at farabi Eye Hospital. Uncorrected visual acuity improved from counting finger to 20/40 or better in 9 eyes (53 percent. The following complications were observed during the mean postoperative follow-up of 7.2 (range 3-12 months; increased intraocular pressure in 5 eyes, vitreous hemorrhage and icr hyphema in 2 eyes, cystoid macular edema (CME and vitritis in one eye, and endophthalmitis and retinal detachment in one eye. Posterior chamber intraocular lens implantation by scleral fixation is a relatively safe procedure and can be recommended for many patients

  11. Optimization of Variable-Depth Liner Configurations for Increased Broadband Noise Reduction

    Science.gov (United States)

    Jones, M. G.; Watson, W. R.; Nark, D. M.; Schiller, N. H.; Born, J. C.

    2016-01-01

    This paper employs three acoustic propagation codes to explore variable-depth liner configurations for the NASA Langley Grazing Flow Impedance Tube (GFIT). The initial study demonstrates that a variable impedance can acceptably be treated as a uniform impedance if the spatial extent over which this variable impedance occurs is less than one-third of a wavelength of the incident sound. A constrained optimization study is used to design a variable-depth liner and to select an optimization metric. It also provides insight regarding how much attenuation can be achieved with variable-depth liners. Another optimization study is used to design a liner with much finer chamber depth resolution for the Mach 0.0 and 0.3 test conditions. Two liners are designed based on spatial rearrangement of chambers from this liner to determine whether the order is critical. Propagation code predictions suggest this is not the case. Both liners are fabricated via additive manufacturing and tested in the GFIT for the Mach 0.0 condition. Predicted and measured attenuations compare favorably across the full frequency range. These results clearly suggest that the chambers can be arranged in any order, thus offering the potential for innovative liner designs to minimize depth and weight.

  12. On the detectability of Teide volcano magma chambers (Tenerife, Canary Islands) with magnetotelluric data

    Science.gov (United States)

    Piña-Varas, Perla; Ledo, Juanjo; Queralt, Pilar; Marcuello, Alex; Perez, Nemesio

    2018-01-01

    Tenerife has been the subject of numerous studies covering a wide range of fields. Many studies have been focused on characterising the magmatic plumbing system. Even so, a controversy still exists regarding the location and size of the current magma chambers. Several magnetotelluric (MT) surveys have been carried out in the island, but no conductivity anomalies associated with the chambers have been detected. We report the results of a set of tests conducted against the 3-D resistivity model of the island, to determine the characteristics of the detectable chambers with the MT data. The most remarkable results indicate that the MT dataset is incompatible with a large-scale mafic reservoir located at shallower depths than 8 km b.s.l. However, shallower phonolitic chambers smaller than 3 × 3 × 1 km3 could be undetected by the existing MT sites and new data should be acquired to confirm or not their existence. This new information is essential in volcanic islands like Tenerife, since many volcanic hazards are related to the size and depth of the sources of magma. Additionally, a joint interpretation of the obtained results together with other information is summarised in a hypothetical model, allowing us to better understand the internal structure of the island.[Figure not available: see fulltext.

  13. Intracorneal ring segment depth in keratoconus patients: a long-term follow-up study.

    Science.gov (United States)

    Shahhoseini, Saied; Hashemi, Hassan; Asgari, Soheila

    2017-06-12

    To compare the actual depth of the tunnel created with femtosecond laser for intracorneal ring segment (ICRS) implantation with the target depth in keratoconus patients. In this mix design study, eligible keratoconus patients were identified through chart review. The inclusion criterion was a history of ICRS implantation with femtosecond laser more than 6 months prior to enrollment. Participants underwent anterior segment optical coherence tomography using Spectralis (Heidelberg Engineering GmbH, Heidelberg, Germany) for depth measurement defined as the distance from the anterior corneal surface to anterior rim of the ring. The mean age of the 30 participants was 31.4 ± 7.9 years, and 58.6% were male. Mean follow-up time after ring implantation was 25.8 ± 10.0 (range 7-41) months. Mean actual depth was 59.9% (42.4-86.8%), and the target depth was 85.0% (74.8-90.0%) (P calculator of the device.

  14. Depth estimation via stage classification

    NARCIS (Netherlands)

    Nedović, V.; Smeulders, A.W.M.; Redert, A.; Geusebroek, J.M.

    2008-01-01

    We identify scene categorization as the first step towards efficient and robust depth estimation from single images. Categorizing the scene into one of the geometric classes greatly reduces the possibilities in subsequent phases. To that end, we introduce 15 typical 3D scene geometries, called

  15. Factors that affect keratotomy depth.

    Science.gov (United States)

    Merlin, U; Bordin, P; Rimondi, A P; Sichirollo, R

    1991-01-01

    The authors investigated nine factors which can affect the depth of incisions performed during refractive keratotomy: (1) vertical vs oblique-cutting edge of the knife blade, (2) direction of cutting, (3) cutting velocity, (4) American vs Russian technique, (5) intraocular pressure (IOP), (6) initial vs final incisions, (7) sharpness of knife blade, (8) single vs double footplate, and (9) square vs double-edged blade. These variables were examined independently, performing at least 40 incisions for each experimental parameter studied. The depth of the resulting incisions was measured histologically using the micrometer eyepiece. The average and the standard deviation were calculated. The paired Student's t-test was used to establish significant differences between the two conditions investigated for each parameter. Factors that were demonstrated to increase significantly the depth of the incisions included: the vertical-cutting edge, the triple-edged diamond knife, the sharpness of the knife, and the single foot knife. High velocity in performing the incisions and, to a lesser extent, low IOP were the main factors that induced irregularity in depth.

  16. PWCs and drift chambers at ISABELLE

    International Nuclear Information System (INIS)

    Okuno, H.; Teramoto, Y.; Wheeler, C.D.

    1978-01-01

    Rate effects in proportional chambers and drift chambers are addressed first. The widely used high-gas-gain chambers would have impaired performance at ISABELLE data rates. Improvement can be expected with lower gas gain, and this possibility is investigated with respect to position and time resolution. Results on chamber lifetime are summarized; space-charge effects, gain saturation, and radiation hardness of electronics are considered. The resolution of drift chambers is discussed in some detail; time resolution, double pulse resolution, and momentum resolution and multiple scattering are included. The expected high multiplicity of tracks from a single event, the high event rates, and the requirement for low gas gain necessitate revision of the methods for measuring the second coordinate. Known methods of two-dimensional point localization are summarized according to spatial accuracy, electronics requirements, and multihit capability. Delay lines, charge division, and cathode strips are considered. Particle identification by means of measurement of the relativistic rise of energy loss by conventional and unconventional means was investigated. 32 references, 3 figures, 4 tables

  17. The wide gap resistive plate chamber

    International Nuclear Information System (INIS)

    Crotty, I.; Lamas Valverde, J.; Hatzifotiadou, D.; Williams, M.C.S.; Zichichi, A.

    1995-01-01

    The resistive plate chamber (RPC) has good time and position resolution; these factors (coupled to its simple construction) make it an attractive candidate for muon trigger systems at future colliders. However, operated in spark mode, the RPC has severe rate problems that make it unusable above 10 Hz/cm 2 . We have previously published our results concerning the operation of the RPC in spark and in avalanche mode; we have shown that the rate limit can be increased to 150 Hz/cm 2 if the RPC is operated in avalanche mode. Here, we discuss the performance of chambers with 6 and 8 mm gas gaps (compared to the more usual 2 mm gap). We outline the reasons for this choice, and also discuss anode versus cathode strip readout. We have measured the efficiency versus flux, and also show that an enhanced rate limit can be obtained if only a small region of the chamber is exposed to the beam (spot illumination). Finally we have tested the performance of chambers constructed with other materials for the resistiv e plate and compare it to chambers constructed with our preferred plastic, melamine laminate. (orig.)

  18. Study and analysis of drift chamber parameters

    International Nuclear Information System (INIS)

    Martinez Laso, L.

    1988-01-01

    The present work deals mainly with drift chambers. In the first chapter a summary of drift chamber properties is presented. The information has been collected from the extensive bibliography available in this field. A very simple calculation procedure of drift chamber parameters has been developed and is presented in detail in the second chapter. Some prototypes have been made following two geometries (multidrift chamber and Z-chambers). Several installations have been used for test and calibration of these prototypes. A complete description of these installations is given in the third chapter. Cosmic rays, beta particles from a Ru106 radiactive source and a test beam in the WA (West Area) of SPS at CERN have been used for experimental purposes. The analysis and the results are described for the different setups. The experimental measurements have been used to produce a complete cell parametrization (position as function of drift time) and to obtain spatial resolution values (in the range of 200-250 um). Experimental results are in good agreement with numerical calculations. (Author)

  19. Investigation of Swirling Flows in Mixing Chambers

    Directory of Open Access Journals (Sweden)

    Jyh Jian Chen

    2011-01-01

    Full Text Available This investigation analyzed the three-dimensional momentum and mass transfer characteristics arising from multiple inlets and a single outlet in micromixing chamber. The chamber consists of a right square prism, an octagonal prism, or a cylinder. Numerical results which were presented in terms of velocity vector plots and concentration distributions indicated that the swirling flows inside the chamber dominate the mixing index. Particle trajectories were utilized to demonstrate the rotational and extensional local flows which produce steady stirring, and the configuration of colored particles at the outlet section expressed at different Re represented the mixing performance qualitatively. The combination of the Taylor dispersion and the vorticity was first introduced and made the mixing successful. The effects of various geometric parameters and Reynolds numbers on the mixing characteristics were investigated. An optimal design of the cylindrical chamber with 4 inlets can be found. At larger Reynolds number, Re>15, more inertia caused the powerful swirling flows in the chamber, and more damping effect on diffusion was diminished, which then increased the mixing performance.

  20. Improvement of Swirl Chamber Structure of Swirl-Chamber Diesel Engine Based on Flow Field Characteristics

    Directory of Open Access Journals (Sweden)

    Wenhua Yuan

    2014-10-01

    Full Text Available In order to improve combustion characteristic of swirl chamber diesel engine, a simulation model about a traditional cylindrical flat-bottom swirl chamber turbulent combustion diesel engine was established within the timeframe of the piston motion from the bottom dead centre (BDC to the top dead centre (TDC with the fluent dynamic mesh technique and flow field vector of gas in swirl chamber and cylinder; the pressure variation and temperature variation were obtained and a new type of swirl chamber structure was proposed. The results reveal that the piston will move from BDC; air in the cylinder is compressed into the swirl chamber by the piston to develop a swirl inside the chamber, with the ongoing of compression; the pressure and temperature are also rising gradually. Under this condition, the demand of diesel oil mixing and combusting will be better satisfied. Moreover, the new structure will no longer forma small fluid retention zone at the lower end outside the chamber and will be more beneficial to the mixing of fuel oil and air, which has presented a new idea and theoretical foundation for the design and optimization of swirl chamber structure and is thus of good significance of guiding in this regard.

  1. Study of pulp chamber morphology of primary mandibular molars using spiral computed tomography.

    Science.gov (United States)

    Selvakumar, Haridoss; Kavitha, Swaminathan; Vijayakumar, Rajendran; Eapen, Thomas; Bharathan, Rajendran

    2014-11-01

    The purpose of this study was to evaluate the pulp chamber morphology in primary mandibular molars using spiral computed tomography (SCT). Sixty extracted primary mandibular molars were scanned using SCT for the (i) distance between the central fissure to furcation, (ii) distance between the central fissure to the floor of the pulp chamber, (iii) height of the pulp chamber (roof-floor), (iv) distance between the floor of the pulp chamber to the furcation. The mean and standard deviation was analyzed using statistical package for the social sciences (SPSS) program. The results of this study show that the average mean distance from the central fissure to the floor of the pulp chamber is 5.07 mm in first mandibular primary molar and 5.54 mm in second mandibular primary molar. It can be concluded that the greatest depth to which a bur can go during access opening without perforating the furcation in first primary mandibular molar is 5.07 mm and 5.54 mm in second primary mandibular molar.

  2. Excitatory and inhibitory effects of prolactin release activated by nerve stimulation in rat anterior pituitary

    Directory of Open Access Journals (Sweden)

    Gao Li-Zhi

    2009-12-01

    Full Text Available Abstract Background A series of studies showed the presence of substantial amount of nerve fibers and their close relationship with the anterior pituitary gland cells. Our previous studies have suggested that aside from the classical theory of humoral regulation, the rat anterior pituitary has direct neural regulation on adrenocorticotropic hormone release. In rat anterior pituitary, typical synapses are found on every type of the hormone-secreting cells, many on lactotrophs. The present study was aimed at investigating the physiological significance of this synaptic relationship on prolactin release. Methods The anterior pituitary of rat was sliced and stimulated with electrical field in a self-designed perfusion chamber. The perfusate was continuously collected in aliquots and measured by radioimmunoassay for prolactin levels. After statistic analysis, differences of prolactin concentrations within and between groups were outlined. Results The results showed that stimulation at frequency of 2 Hz caused a quick enhancement of prolactin release, when stimulated at 10 Hz, prolactin release was found to be inhibited which came slower and lasted longer. The effect of nerve stimulation on prolactin release is diphasic and frequency dependent. Conclusions The present in vitro study offers the first physiological evidence that stimulation of nerve fibers can affect prolactin release in rat anterior pituitary. Low frequency stimulation enhances prolactin release and high frequency mainly inhibits it.

  3. Anterior capsular staining with trypan blue for capsulorhexis in mature and hypermature cataracts. A preliminary study

    Directory of Open Access Journals (Sweden)

    Kothari Kulin

    2001-01-01

    Full Text Available Purpose: To study the efficacy and safety of 0.1% Trypan Blue dye to stain the anterior capsule for capsulorhexis in mature and hypermature cataracts. Methods: This preliminary study included 25 eyes of 25 patients with a unilateral mature or hypermature cataract, including one case of traumatic mature cataract. In all these cases 0.2ml of 0.1% trypan blue dye was used to stain the anterior capsule. The efficacy and safety of the dye was evaluated on the basis of intraoperative and postoperative observations. Results: In all 25 eyes the capsulorhexis was completed. There was peripheral extension of the capsulorhexis in the eye with traumatic cataract and the stained edge of the anterior capsule helped identification and redirection of the capsulorhexis. Successful phacoemulsification with intraocular lens implantation was performed in all eyes. Adverse reactions related to the dye such as raised intraocular pressure, anterior chamber inflammation and endothelial damage were not observed in the immediate postoperative period or at the end of mean follow-up of 3 months. Conclusion: Trypan blue dye staining of the anterior capsule appears to be a very useful and safe technique that simplifies capsulorhexis in mature and hypermature cataracts.

  4. Effects of primary selective laser trabeculoplasty on anterior segment parameters

    Directory of Open Access Journals (Sweden)

    Suzan Guven Yilmaz

    2015-10-01

    Full Text Available AIM:To investigate the effects of selective laser trabeculoplasty (SLT on the main numerical parameters of anterior segment with Pentacam rotating Scheimpflug camera in patients with ocular hypertension (OHT and primary open angle glaucoma (POAG.METHODS: Pentacam measurements of 45 eyes of 25 (15 females and 10 males patients (12 with OHT, 13 with POAG before and after SLT were obtained. Measurements were taken before and 1 and 3mo after SLT. Pentacam parameters were compared between OHT and POAG patients, and age groups (60y and older, and younger than 60y.RESULTS: The mean age of the patients was 57.8±13.9 (range 20-77y. Twelve patients (48% were younger than 60y, while 13 patients (52% were 60y and older. Measurements of pre-SLT and post-SLT 1mo were significantly different for the parameters of central corneal thickness (CCT and anterior chamber volume (ACV (P<0.05. These parameters returned back to pre-SLT values at post-SLT 3mo. Decrease of ACV at post-SLT 1mo was significantly higher in younger than 60y group than 60y and older group. There was no statistically significant difference in Pentacam parameters between OHT and POAG patients at pre- and post-treatment measurements (P>0.05.CONCLUSION:SLT leads to significant increase in CCT and decrease in ACV at the 1st month of the procedure. Effects of SLT on these anterior segment parameters, especially for CCT that interferes IOP measurement, should be considered to ensure accurate clinical interpretation.

  5. Repair of isolated double-chambered right ventricle | El Kouache ...

    African Journals Online (AJOL)

    The finding of a double-chambered right ventricle (DCRV) is exceptionally rare as an isolated anomaly. It is a congenital cardiac anomaly in which the right ventricle is separated into two chambers, a proximal highpressure chamber and a distal low-pressure chamber, by anomalous muscles or fibrous tissues in the right ...

  6. The Mark III vertex chamber and prototype test results

    International Nuclear Information System (INIS)

    Grab, C.

    1987-07-01

    A vertex chamber has been constructed for use in the Mark III experiment. The chamber is positioned inside the current main drift chamber and will be used to trigger data collection, to aid in vertex reconstruction, and to improve the momentum resolution. This paper discusses the chamber's construction and performance and tests of the prototype

  7. High intensity electromagnetic field gerenation using a transportable reverberation chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2008-01-01

    A reverberation chamber can create very high field strength with moderate input power. Existing chambers are making use of a paddle wheel to change the resonant modes in the chamber. A transportable reverberation chamber with vibrating walls will be presented. Inside this Vibrating Intrinsic

  8. Anterior chest wall examination reviewed

    Directory of Open Access Journals (Sweden)

    F. Trotta

    2011-09-01

    Full Text Available Anterior chest wall involvement is not infrequently observed within inflammatory arthropaties, particularly if one considers seronegative spondiloarthritides and SAPHO syndrome. Physical examination is unreliable and conventional X-rays analysis is an unsatisfactory tool during diagnostic work-up of this region. Scintigraphic techniques yield informations both on the activity and on the anatomical extent of the disease while computerized tomography visualize the elementary lesions, such as erosions, which characterize the process. Moreover, when available, magnetic resonance imaging couple the ability to finely visualize such lesions with the possibility to show early alterations and to characterize the “activity” of the disease, presenting itself as a powerful tool both for diagnosis and follow-up. This review briefly shows the applications of imaging techniques for the evaluation of the anterior chest wall focusing on what has been done in the SAPHO syndrome which can be considered prototypical for this regional involvement since it is the osteo-articular target mainly affected by the disease.

  9. [Anterior skull-base schwannoma].

    Science.gov (United States)

    Esquivel-Miranda, Miguel; De la O Ríos, Elier; Vargas-Valenciano, Emmanuelle; Moreno-Medina, Eva

    Schwannomas are nerve sheath tumours that originate in Schwann cells. They are usually solitary and sporadic and manifest on peripheral, spinal or cranial nerves. Intracranial schwannomas tend to manifest on the eighth cranial nerve, particularly in patients with neurofibromatosis type2. Anterior skull-base schwannomas represent less than 1% of all intracranial schwannomas. They are more frequent in young people and are typically benign. These tumours represent a diagnostic challenge due to their rarity and difficult differential diagnosis, and numerous theories have been postulated concerning their origin and development. In this article, we present the case of a 13-year-old male with a single anterior cranial-base tumour not associated with neurofibromatosis who presented with headache, papilloedema, eye pain and loss of visual acuity. Complete resection of the tumour was performed, which was histopathologically diagnosed as a schwannoma. The patient made a complete clinical recovery with abatement of all symptoms. We conducted a review of the literature and found 66 cases worldwide with this diagnosis. We describe the most relevant epidemiological and clinical characteristics of this kind of tumour and its relation with the recently discovered and similar olfactory schwannoma. Copyright © 2017 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Change of Pressing Chamber Conicalness at Briquetting Process in Briquetting Machine Pressing Chamber

    Directory of Open Access Journals (Sweden)

    Peter Križan

    2012-01-01

    Full Text Available In this paper, we will present the impact of the conical shape of a pressing chamber, an important structural parameter. Besides the known impact of the technological parameters of pressing chambers, it is also very important to pay attention to their structural parameters. In the introduction, we present a theoretical analysis of pressing chamber conicalness. An experiment aimed at detecting this impact was performed at our institute, and it showed that increasing the conicalness of a pressing chamber improves the quality of the final briquettes. The conicalness of the pressing chamber has a significanteffect on the final briquette quality and on the construction of briquetting machines. The experimental findings presented here show the importance of this parameter in the briquetting process.

  11. Commissioning of SLAC SLD 45-Degree Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Eschenburg, Vance O.

    2002-07-19

    The SLD experiment at the Stanford Linear Accelerator Center had a significant gap in its muon tracking coverage, provided by the Warm Iron Calorimeter. Supplemental planes of limited streamer tube chambers were added to improve the coverage in the vicinity of the gap at 0.65 < |cos{theta}| < 0.85. A software effort to upgrade the tracking software for this system is detailed. The commissioning of the forty-five degree chamber region of the SLAC SLD Warm Iron Calorimeter is presented. This task involved the completion of the forty-five degree chamber region geometry for the Warm Iron Calorimeter's fitter and swimmer and the changing of the way multiple scattering effects are treated in the fitter algorithm.

  12. High temperature thrust chamber for spacecraft

    Science.gov (United States)

    Chazen, Melvin L. (Inventor); Mueller, Thomas J. (Inventor); Kruse, William D. (Inventor)

    1998-01-01

    A high temperature thrust chamber for spacecraft (20) is provided herein. The high temperature thrust chamber comprises a hollow body member (12) having an outer surface and an internal surface (16) defining the high temperature chamber (10). The body member (12) is made substantially of rhenium. An alloy (18) consisting of iridium and at least alloying metal selected of the group consisting of rhodium, platinum and palladium is deposited on at least a portion of the internal surface (16) of the body member (12). The iridium and the alloying metal are electrodeposited onto the body member (12). A HIP cycle is performed upon the body member (12) to cause the coating of iridium and the alloying metal to form the alloy (18) which protects the body member (12) from oxidation.

  13. Posing the first LEAR vacuum chamber

    CERN Multimedia

    1982-01-01

    The photo shows one of the four bending magnets of LEAR. They were of C-type with the opening ('mouth') to the outside of the ring (yoke to the inside). Last preparations are made before the vacuum chamber is slid through the mouth into the magnet. Stochastic cooling pickups/kickers were installed inside the chamber. One can distinguish a large number of feed-throughs on the chamber (leading to the pickup/kicker gaps). The free space in the middle of the block was left to offer room for an internal target in the magnet. This possibility was never exploited. Instead it is used here, to accommodate a pumping port for the high vacuum system. Michel Chanel (left) and Pierre Lefevre admire the mechanics at work.

  14. Rapid-Cycling Bubble-Chamber, details

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    Parts of the hydraulic expansion system of the Rapid-Cycling Bubble-Chamber (RCBC). RCBC was the largest of 3 rapid-cycling bubble-chambers (the others were LEBC and HOLEBC), used as target- and vertex-detectors within the European Hybrid Spectrometer (EHS) in the SPS North Area (EHN1). RCBC contained 250 l of liquid hydrogen and was located inside a 3 T superconducting magnet. It was designed for 30 expansions/s (100 times faster than BEBC), the system shown here allowed 50 expansions/s. RCBC operated from 1981 to 1983 for experiments NA21, NA22 and NA23 at a rate of 15 expansions/s, clocking up a total of over 4 million. In the rear, at left, is bearded Lucien Veillet; Augustin Didona is at the right. See also 8001009. The installation of the piston assembly in the RCBC chamber body is shown in the Annual Report 1980, p.65.

  15. Emulsion chamber experiments for the Space Station

    Science.gov (United States)

    Wilkes, R. J.

    Emulsion chambers offer several unique features for the study of ultrahigh-energy cosmic-ray interactions and spectra aboard a permanent manned Space Station. Emulsion-chamber experiments provide the highest acceptance/weight ratio of any current experimental technique, are invulnerable to mechanical shocks and temperature excursions associated with space flight, do not employ volatile or explosive components or materials, and are not dependent upon data communications or recording systems. Space-Station personnel would be employed to replace track-sensitive materials as required by background accumulation. Several emulsion-chamber designs are proposed, including both conventional passive calorimetric detectors and a hybrid superconducting-magnetic-spectrometer system. Results of preliminary simulation studies are presented. Operational logistics are discussed.

  16. Design of the CLIC Quadrupole Vacuum Chambers

    CERN Document Server

    Garion, C

    2010-01-01

    The Compact Linear Collider, under study, requires vacuum chambers with a very small aperture, of the order of 8 mm in diameter, and with a length up to around 2 m for the main beam quadrupoles. To keep the very tight geometrical tolerances on the quadrupoles, no bake out is allowed. The main issue is to reach UHV conditions (typically 10-9 mbar static pressure) in a system where the vacuum performance is driven by water outgassing. For this application, a thinwalled stainless steel vacuum chamber with two ante chambers equipped with NEG strips, is proposed. The mechanical design, especially the stability analysis, is shown. The key technologies of the prototype fabrication are given. Vacuum tests are carried out on the prototypes. The test set-up as well as the pumping system conditions are presented.

  17. ON THE ANALYSIS OF BUBBLE CHAMBER TRACKS

    International Nuclear Information System (INIS)

    Bradner, H.; Solmitz, F.

    1958-01-01

    Since its invention by Glaser in 1953, the bubble chamber has become a most valuable tool in high-energy physics. It combines a number of advantages of various older methods of particle detection: it offers high spatial resolution, rapid accumulation of data, some time resolution, and some choice of the nucleus whose interaction one wants to study (bubble chambers have been made to operate with a large number of different liquids, including H 2 , D 2 , He, Xe, and several hydrocarbons). In order to exploit the advantages of spatial resolution and rapid data accumulation, high-speed high-precision analysis procedures must be developed. In this article they discuss some of the problems posed by such analysis. The discussion is based largely on experience gained in performing hydrogen bubble chamber experiments with the University of California's Bevatron (6-Bev proton synchrotron)

  18. Posterior Chamber Scleral Fixation of Intraocular Lenses in Post-Vitrectomised Aphakic Eyes.

    Science.gov (United States)

    Obeng, Francis Kwasi; Vig, Vipan Kumar; Singh, Preetam; Singh, Rajbir; Dhawan, Bodhraj; Sahajpal, Nikhil

    2017-03-01

    The best method of aphakia correction is in the bag implantation of Posterior Chamber Intraocular Lens (PCIOL). When this ideal procedure is not possible due to lack of integrity of posterior capsule or zonules, the other alternatives are broadly categorized into two: extraocular and intraocular. Whereas, the former includes contact lenses and aphakic glasses, the latter ones are further divided into anterior and posterior chamber methods. Anterior Chamber Intraocular Lenses (ACIOL) can be with or without iris claw. At the posterior chamber, fixation of the lenses can be with glue or sutures. When there is combined Pars Plana Vitrectomy (PPV) and lensectomy or if the indication of PPV is dropped nucleus or intraocular lens, a modality of aphakia correction should be devised. Posterior Chamber Scleral Fixation of Intraocular Lenses (PCSFIOL) with sutures is a preferred method because of its low complication profile. However, data on correction of aphakia after combined PPV and lensectomy is limited. To fill in this gap in knowledge, we evaluated the secondary PCSFIOL in aphakic eyes after previous PPV and lensectomy. To assess the outcome and complication profile of a large series of patients who underwent secondary PCSFIOL implantation with sutures after combined PPV and lensectomy. Records of all patients who had undergone secondary PCSFIOL implantation with sutures after combined PPV and lensectomy from 2010 to 2014 were reviewed retrospectively for visual outcomes and complications. Patients' demographic data, indication for PPV, best corrected preoperative and postoperative visual acuities, complications of surgery, and indications of PCSFIOL and length of follow up were collected and analyzed. A total of 148 eyes of 148 patients (127 males and 21 females) were identified. Mean age at surgery was 32.5±8 years (range 2.5-73 years) with a mean follow up 23±14 months (range 3-114 months). A total of 95.27%, 2.70% and 2.02% of patients had improvement

  19. Posterior Chamber Scleral Fixation of Intraocular Lenses in Post-Vitrectomised Aphakic Eyes

    Science.gov (United States)

    Vig, Vipan Kumar; Singh, Preetam; Singh, Rajbir; Dhawan, Bodhraj; Sahajpal, Nikhil

    2017-01-01

    Introduction The best method of aphakia correction is in the bag implantation of Posterior Chamber Intraocular Lens (PCIOL). When this ideal procedure is not possible due to lack of integrity of posterior capsule or zonules, the other alternatives are broadly categorized into two: extraocular and intraocular. Whereas, the former includes contact lenses and aphakic glasses, the latter ones are further divided into anterior and posterior chamber methods. Anterior Chamber Intraocular Lenses (ACIOL) can be with or without iris claw. At the posterior chamber, fixation of the lenses can be with glue or sutures. When there is combined Pars Plana Vitrectomy (PPV) and lensectomy or if the indication of PPV is dropped nucleus or intraocular lens, a modality of aphakia correction should be devised. Posterior Chamber Scleral Fixation of Intraocular Lenses (PCSFIOL) with sutures is a preferred method because of its low complication profile. However, data on correction of aphakia after combined PPV and lensectomy is limited. To fill in this gap in knowledge, we evaluated the secondary PCSFIOL in aphakic eyes after previous PPV and lensectomy. Aim To assess the outcome and complication profile of a large series of patients who underwent secondary PCSFIOL implantation with sutures after combined PPV and lensectomy. Materials and Methods Records of all patients who had undergone secondary PCSFIOL implantation with sutures after combined PPV and lensectomy from 2010 to 2014 were reviewed retrospectively for visual outcomes and complications. Patients’ demographic data, indication for PPV, best corrected preoperative and postoperative visual acuities, complications of surgery, and indications of PCSFIOL and length of follow up were collected and analyzed. Results A total of 148 eyes of 148 patients (127 males and 21 females) were identified. Mean age at surgery was 32.5±8 years (range 2.5-73 years) with a mean follow up 23±14 months (range 3-114 months). A total of 95.27%, 2

  20. Sonourethrography of anterior urethral strictures: assessment of length and degree

    International Nuclear Information System (INIS)

    Kim, Jong Chul; Jeong, Youn Sin

    1994-01-01

    We reviewed out experience of sonourethrography(SUG) in male anterior urethral strictures to correlate the stricture length and degree seen on SUG with those on urethroscopy, surgery or biopsy. During the recent 6 years,both the retrograde urethrography (RUG) and SUG were preformed in 50 occasions for 47 patients with anteriorurethral stricture, that were subsequently evaluated urethroscopically or at surgery. As a whole, the length of the stricture seen on SUG did not correlate very well with that seen on RGU (r2=0.71, p<0.005). Considering the data from the operation as the gold standard, SUG was more accurate than RUG in depicting the exact stricturelength (r2=0.97 and 0.75 respectively,p<0.005). The shorter the lesion, the more accurate the data obtained.Although SUG certainly identified periurethral tissue, it was not adequate in predicting the depth of spongiofibrosis compared with full-depth biopsies in 20 patients. In conclusion, SUG, a dynamic study, accurately defined the stricture site, number and calibre. When compared with RUG, SUG was more accurate in the measurement of stricture length and in the demonstration of periurethral tissue, making it a valuable method in the evaluation of patients with suspected anterior urethral strictures