WorldWideScience

Sample records for annular centrifugal contactors

  1. Fluidic Analysis in an Annular Centrifugal Contactor for Fuel Reprocessing

    International Nuclear Information System (INIS)

    An annular centrifugal contactor (ACC) is a promising device for fuel reprocessing process, because it offers several advantages—a smaller size, a smaller holdup volume, and a higher separation performance—over conventional contactors such as a mixer-settler and a pulse column. Fluid dynamics and dispersion in an ACC, which has a combined mixer/centrifuge structure, are closely related to its separation performance and capacity, and this information is useful in improving equipment design. In this paper, experimental and computational fluid dynamics (CFD) studies were conducted to analyze fluidic and dispersion behavior in ACCs. Multiphase mixing (water/TBP-dodecane/air) in the annular zone was observed by Particle Imaging Velocimetry, and the change in the fluidic and dispersion behavior was ascertained under several operational conditions. The results of the CFD studies, which considered multiphase turbulent flow in the annular and rotor interior zones, were in a good agreement with the experimental data. (author)

  2. Liquid–Liquid Mixing Studies in Annular Centrifugal Contactors Comparing Stationary Mixing Vane Options

    Energy Technology Data Exchange (ETDEWEB)

    Wardle, Kent E.

    2015-11-10

    Comparative studies of multiphase operation of annular centrifugal contactors showing the impact of housing stationary mixing vane configuration. A number of experimental results for several different mixing vane options are reported with selected measurements in a lab-scale 5 cm contactor and 12.5 cm engineering-scale unit. Fewer straight vanes give greater mixingzone hold-up compared to curved vanes. Quantitative comparison of droplet size distribution also showed a significant decrease in mean diameter for four straight vanes versus eight curved vanes. This set of measurements gives a compelling case for careful consideration of mixing vane geometry when evaluating hydraulic operation and extraction process efficiency of annular centrifugal contactors.

  3. Hybrid multiphase CFD simulation for liquid-liquid interfacial area prediction in annular centrifugal contactors

    International Nuclear Information System (INIS)

    Liquid-liquid contacting equipment used in solvent extraction processes has the dual purpose of mixing and separating two immiscible fluids. Consequently, such devices inherently encompass a wide variety of multiphase flow regimes. A hybrid multiphase computational fluid dynamics (CFD) solver which combines the Eulerian multi-fluid method with VOF (volume of fluid) sharp interface capturing has been developed for application to annular centrifugal contactors. This solver has been extended to enable prediction of mean droplet size and liquid-liquid interfacial area through a single moment population balance method. Simulations of liquid-liquid mixing in a simplified geometry and a model annular centrifugal contactor are reported with droplet breakup/coalescence models being calibrated versus available experimental data. Quantitative comparison is made for two different housing vane geometries and it is found that the predicted droplet size is significantly smaller for vane geometries which result in higher annular liquid holdup

  4. Hybrid multiphase CFD simulation for liquid-liquid interfacial area prediction in annular centrifugal contactors

    Energy Technology Data Exchange (ETDEWEB)

    Wardle, K.E. [Chemical Sciences and Engineering Division, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2013-07-01

    Liquid-liquid contacting equipment used in solvent extraction processes has the dual purpose of mixing and separating two immiscible fluids. Consequently, such devices inherently encompass a wide variety of multiphase flow regimes. A hybrid multiphase computational fluid dynamics (CFD) solver which combines the Eulerian multi-fluid method with VOF (volume of fluid) sharp interface capturing has been developed for application to annular centrifugal contactors. This solver has been extended to enable prediction of mean droplet size and liquid-liquid interfacial area through a single moment population balance method. Simulations of liquid-liquid mixing in a simplified geometry and a model annular centrifugal contactor are reported with droplet breakup/coalescence models being calibrated versus available experimental data. Quantitative comparison is made for two different housing vane geometries and it is found that the predicted droplet size is significantly smaller for vane geometries which result in higher annular liquid holdup.

  5. Evaluation of Argonne 9-cm and 10-cm Annular Centrifugal Contactors for SHINE Solution Processing

    International Nuclear Information System (INIS)

    Work is in progress to evaluate the SHINE Medical Technologies process for producing Mo-99 for medical use from the fission of dissolved low-enriched uranium (LEU). This report addresses the use of Argonne annular centrifugal contactors for periodic treatment of the process solution. In a letter report from FY 2013, Pereira and Vandegrift compared the throughput and physical footprint for the two contactor options available from CINC Industries: the V-02 and V-05, which have rotor diameters of 5 cm and 12.7 cm, respectively. They suggested that an intermediately sized Goldilocks contactor might provide a better balance between throughput and footprint to meet the processing needs for the uranium extraction (UREX) processing of the SHINE solution to remove undesired fission products. Included with the submission of this letter report are the assembly drawings for two Argonne-design contactors that are in this intermediate range 9-cm and 10-cm rotors, respectively. The 9-cm contactor (drawing number CE-D6973A, stamped February 15, 1978) was designed as a single-stage unit and built and tested in the late 1970s along with other size units, both smaller and larger. In subsequent years, a significant effort to developed annular centrifugal contactors was undertaken to support work at Hanford implementing the transuranic extraction (TRUEX) process. These contactors had a 10-cm rotor diameter and were fully designed as multistage units with four stages per assembly (drawing number CMT-E1104, stamped March 14, 1990). From a technology readiness perspective, these 10-cm units are much farther ahead in the design progression and, therefore, would require significantly less re-working to make them ready for UREX deployment. Additionally, the overall maximum throughput of ~12 L/min is similar to that of the 9-cm unit (10 L/min), and the former could be efficiently operated over much of the same range of throughput. As a result, only the 10-cm units are considered here, though

  6. Evaluation of Argonne 9-cm and 10-cm Annular Centrifugal Contactors for SHINE Solution Processing

    Energy Technology Data Exchange (ETDEWEB)

    Wardle, Kent E. [Argonne National Lab. (ANL), Argonne, IL (United States); Pereira, Candido [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, George [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-02-01

    Work is in progress to evaluate the SHINE Medical Technologies process for producing Mo-99 for medical use from the fission of dissolved low-enriched uranium (LEU). This report addresses the use of Argonne annular centrifugal contactors for periodic treatment of the process solution. In a letter report from FY 2013, Pereira and Vandegrift compared the throughput and physical footprint for the two contactor options available from CINC Industries: the V-02 and V-05, which have rotor diameters of 5 cm and 12.7 cm, respectively. They suggested that an intermediately sized “Goldilocks” contactor might provide a better balance between throughput and footprint to meet the processing needs for the uranium extraction (UREX) processing of the SHINE solution to remove undesired fission products. Included with the submission of this letter report are the assembly drawings for two Argonne-design contactors that are in this intermediate range—9-cm and 10-cm rotors, respectively. The 9-cm contactor (drawing number CE-D6973A, stamped February 15, 1978) was designed as a single-stage unit and built and tested in the late 1970s along with other size units, both smaller and larger. In subsequent years, a significant effort to developed annular centrifugal contactors was undertaken to support work at Hanford implementing the transuranic extraction (TRUEX) process. These contactors had a 10-cm rotor diameter and were fully designed as multistage units with four stages per assembly (drawing number CMT-E1104, stamped March 14, 1990). From a technology readiness perspective, these 10-cm units are much farther ahead in the design progression and, therefore, would require significantly less re-working to make them ready for UREX deployment. Additionally, the overall maximum throughput of ~12 L/min is similar to that of the 9-cm unit (10 L/min), and the former could be efficiently operated over much of the same range of throughput. As a result, only the 10-cm units are considered here

  7. Application of annular centrifugal contactors in the hot test of the improved total partitioning process for high level liquid waste

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Wuhua, E-mail: dwh203@mail.tsinghua.edu.cn; Chen, Jing; Wang, Jianchen; Wang, Shuwei; Feng, Xiaogui; Wang, Xinghai; Li, Shaowei; Xu, Chao

    2014-08-15

    Highlights: • An improved total partitioning process for high level liquid waste was developed. • Genuine high level liquid waste was used in the hot test. • 72-Stage 10-mm-dia annular centrifugal contactors were used in the hot test. • The decontamination factors of actinides, Sr and Cs were very high. • The stripping efficiencies of actinides, Sr and Cs were very high. - Abstract: High level liquid waste (HLLW) produced from the reprocessing of the spent nuclear fuel still contains moderate amounts of uranium, transuranium (TRU) actinides, {sup 90}Sr, {sup 137}Cs, etc., and thus constitutes a permanent hazard to the environment. The partitioning and transmutation (P and T) strategy has increasingly attracted interest for the safe treatment and disposal of HLLW, in which the partitioning of HLLW is one of the critical technical issues. An improved total partitioning process, including a TRPO (tri-alkylphosphine oxide) process for the removal of actinides, a CESE (crown ether strontium extraction) process for the removal of Sr, and a CECE (calixcrown ether cesium extraction) process for the removal of Cs, has been developed to treat Chinese HLLW. A 160-hour hot test of the improved total partitioning process was carried out using 72-stage 10-mm-dia annular centrifugal contactors (ACCs) and genuine HLLW. The hot test results showed that the average DFs of total α activity, Sr and Cs were 3.57 × 10{sup 3}, 2.25 × 10{sup 4} and 1.68 × 10{sup 4} after the hot test reached equilibrium, respectively. During the hot test, 72-stage 10-mm-dia ACCs worked stable, continuously with no stage failing or interruption of the operation.

  8. CFD Simulation of Annular Centrifugal Extractors

    OpenAIRE

    Vedantam, S.; Wardle, K. E.; Tamhane, T. V.; Ranade, V. V.; Joshi, J. B.

    2012-01-01

    Annular centrifugal extractors (ACE), also called annular centrifugal contactors offer several advantages over the other conventional process equipment such as low hold-up, high process throughput, low residence time, low solvent inventory and high turn down ratio. The equipment provides a very high value of mass transfer coefficient and interfacial area in the annular zone because of the high level of power consumption per unit volume and separation inside the rotor due to the high g of cent...

  9. Experimental Measurements of Drop Size Distributions in 30 mm Diameter Annular Centrifugal Contactor with 30% TBP-Nitric Acid Biphasic System

    Directory of Open Access Journals (Sweden)

    Shekhar Kumar

    2013-01-01

    Full Text Available For design and development of liquid-liquid extraction systems, it is essential to have an accurate estimation of hydrodynamic and mass transfer characteristics of the employed contactor. In the present study, experimental evaluations consisted primarily of determining the maximum solution throughput that could be processed without cross-phase contamination at a given rotor speed, O/A flow ratio, and organic-aqueous solution pair in a 30 mm bowl diameter centrifugal contactor. In addition, analysis included experimental drop size determinations as well as holdup determination. The experimental drop size distributions are expected to be helpful for modeling work.

  10. CFD Simulation of Annular Centrifugal Extractors

    Directory of Open Access Journals (Sweden)

    S. Vedantam

    2012-01-01

    Full Text Available Annular centrifugal extractors (ACE, also called annular centrifugal contactors offer several advantages over the other conventional process equipment such as low hold-up, high process throughput, low residence time, low solvent inventory and high turn down ratio. The equipment provides a very high value of mass transfer coefficient and interfacial area in the annular zone because of the high level of power consumption per unit volume and separation inside the rotor due to the high g of centrifugal field. For the development of rational and reliable design procedures, it is important to understand the flow patterns in the mixer and settler zones. Computational Fluid Dynamics (CFD has played a major role in the constant evolution and improvements of this device. During the past thirty years, a large number of investigators have undertaken CFD simulations. All these publications have been carefully and critically analyzed and a coherent picture of the present status has been presented in this review paper. Initially, review of the single phase studies in the annular region has been presented, followed by the separator region. In continuation, the two-phase CFD simulations involving liquid-liquid and gas-liquid flow in the annular as well as separator regions have been reviewed. Suggestions have been made for the future work for bridging the existing knowledge gaps. In particular, emphasis has been given to the application of CFD simulations for the design of this equipment.

  11. Characteristics of centrifugal rapid contactor, (3)

    International Nuclear Information System (INIS)

    Organic solvent yields the degradation product as a result of irradiation, in the extraction process of spent fuel reprocessing. The development of a centrifugal rapid contactor is required for the reduction of the solvent degradation by shortening the contact time. The effects of fine solid particles were investigated with a SGN-Robatel LX-208N contactor, following the uranium extraction and re-extraction performance tests. It was found as the experimental result that the considerable quantity of solids accumulated in the rotor of the centrifugal contactor. As for this experimental apparatus, the flow diagram for the centrifugal rapid contactor and auxiliary apparatuses is shown, which are the same system used for the uranium extraction and re-extraction tests. The schematic diagram, the typical stage construction and fluid transfer path of the LX-208 contactor are illustrated. The main specifications of the LX-208 contactor are as follows: the internal diameter of a rotating bowl 200 mm, the material SUS 316, the number of stages 8, and the total hold-up volume of the contactor 1.8 l. Most tests were carried out with aqueous feed only, because white Alundum is easily deposited in the rotor, and the particle concentration in effluent stream becomes undetectable when organic and aqueous feeds are supplied simultaneously. As the experimental results, the correlation of Alundum concentration in effluent and running time, the effect of rotor speed on effluent stream concentration, the particle size distribution curves for No. 6000 and No. 8000 white Alundum, the effect of flow rate on effluent stream concentration and the effect of flow rate on particle size distribution for both No. 6000 and No. 8000 white Alundum are presented. (Nakai, Y.)

  12. A vibration model for centrifugal contactors

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, R.A.; Wasserman, M.O.; Wygmans, D.G.

    1992-11-01

    Using the transfer matrix method, we created the Excel worksheet ``Beam`` for analyzing vibrations in centrifugal contactors. With this worksheet, a user can calculate the first natural frequency of the motor/rotor system for a centrifugal contactor. We determined a typical value for the bearing stiffness (k{sub B}) of a motor after measuring the k{sub B} value for three different motors. The k{sub B} value is an important parameter in this model, but it is not normally available for motors. The assumptions that we made in creating the Beam worksheet were verified by comparing the calculated results with those from a VAX computer program, BEAM IV. The Beam worksheet was applied to several contactor designs for which we have experimental data and found to work well.

  13. Recent advances in centrifugal contactors design

    International Nuclear Information System (INIS)

    Advances in thedesign of the Argonne centrifugal contactor for solvent extaction are being realized as these contactors are built, tested, and used to implement the TRUEX process for the cleanup of nuclear waste liquids. These advances include (1) using off-the-shelf, face-mounted motors, (2) modifying the contractor so that relatively volatile solvents can be used, (3) adding a high-level liquid detector that can be used to alert the plant operator of process upsets, (4) providing secondary feed ports, (5) optimizing support frame design, (6) maintaining a linear design with external interstage lines so the stages can be allocated as needed for extraction, scrub, strip, and solvent cleanup operations, and (7) developing features that facilitate contractor operation in remote facilities. 11 refs., 8 figs

  14. Hydraulic Performance and Mass Transfer Efficiency of Engineering Scale Centrifugal Contactors

    Energy Technology Data Exchange (ETDEWEB)

    David Meikrantz; Troy Garn; Nick Mann; Jack Law; Terry Todd

    2007-09-01

    Annular centrifugal contactors (ACCs) are being evaluated for process-scale solvent extraction operations in support of Advanced Fuel Cycle Initiative (AFCI) separations goals. Process-scale annular centrifugal contactors have the potential for high stage efficiency if properly employed and optimized for the application. Hydraulic performance issues related to flow instability and classical flooding are likely unimportant, especially for units with high throughputs. However, annular mixing increases rapidly with increasing rotor diameter while maintaining a fixed g force at the rotor wall. In addition, for engineering/process-scale contactors, elevated rotor speeds and/or throughput rates, can lead to organic phase foaming at the rotor discharge collector area. Foam buildup in the upper rotor head area can aspirate additional vapor from the contactor housing resulting in a complete loss of separation equilibrium. Variable speed drives are thus desirable to optimize and balance the operating parameters to help ensure acceptable performance. Proper venting of larger contactors is required to balance pressures across individual stages and prevent vapor lock due to foam aspiration.

  15. Centrifugal contactor operations for UREX process flowsheet. An update

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Candido [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, George F. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2014-08-01

    The uranium extraction (UREX) process separates uranium, technetium, and a fraction of the iodine from the other components of the irradiated fuel in nitric acid solution. In May 2012, the time, material, and footprint requirements for treatment of 260 L batches of a solution containing 130 g-U/L were evaluated for two commercial annular centrifugal contactors from CINC Industries. These calculated values were based on the expected volume and concentration of fuel arising from treatment of a single target solution vessel (TSV). The general conclusions of that report were that a CINC V-2 contactor would occupy a footprint of 3.2 m 2 (0.25 m x 15 m) if each stage required twice the nominal footprint of an individual stage, and approximately 1,131 minutes or nearly 19 hours is required to process all of the feed solution. A CINC V-5 would require approximately 9.9 m 2 (0.4 m x 25 m) of floor space but would require only 182 minutes or ~ 3 hours to process the spent target solution. Subsequent comparison with the Modular Caustic Side Solvent Extraction Unit (MCU) at Savannah River Site (SRS) in October 2013 suggested that a more compact arrangement is feasible, and the linear dimension for the CINC V-5 may be reduced to about 8 m; a comparable reduction for the CINC V-2 yields a length of 5 m. That report also described an intermediate-scale (10 cm) contactor design developed by Argonne in the early 1980s that would better align with the SHINE operations as they stood in May 2012. In this report, we revisit the previous evaluation of contactor operations after discussions with CINC Industries and analysis of the SHINE process flow diagrams for the cleanup of the TSV, which were not available at the time of the first assessment.

  16. Centrifugal contactor with liquid mixing and flow control vanes and method of mixing liquids of different phases

    Science.gov (United States)

    Jubin, Robert T.; Randolph, John D.

    1991-01-01

    The invention is directed to a centrifugal contactor for solvent extraction systems. The centrifugal contactor is provided with an annular vertically oriented mixing chamber between the rotor housing and the rotor for mixing process liquids such as the aqueous and organic phases of the solvent extraction process used for nuclear fuel reprocessing. A set of stationary helically disposed vanes carried by the housing is in the lower region of the mixing chamber at a location below the process-liquid inlets for the purpose of urging the liquids in an upward direction toward the inlets and enhancing the mixing of the liquids and mass transfer between the liquids. The upper region of the mixing vessel above the inlets for the process liquids is also provided with a set helically disposed vanes carried by the housing for urging the process liquids in a downward direction when the liquid flow rates through the inlets are relatively high and the liquids contact the vane set in the upper region. The use of these opposing vane sets in the mixing zone maintains the liquid in the mixing zone at suitable levels.

  17. Synthesis and refining of sunflower biodiesel in a cascade of continuous centrifugal contactor separators

    NARCIS (Netherlands)

    Bin Abu Ghazali, Yusuf; van Ulden, Wouter; van de Bovenkamp, Hendrik; Teddy, T; Picchioni, Francesco; Manurung, Robert; Heeres, Hero J.

    2015-01-01

    The synthesis of fatty acid methyl esters (FAME) from sunflower oil and methanol was studied in a continuous centrifugal contactor separator (CCCS) using sodium methoxide as the catalyst. The effect of relevant process variables like oil and methanol flow rate, rotational speed and catalyst concentr

  18. Novel highly integrated biodiesel production technology in a centrifugal contactor separator device

    NARCIS (Netherlands)

    Kraai, G. N.; Schuur, B.; van Zwol, F.; van de Bovenkamp, H. H.; Heeres, H. J.

    2009-01-01

    The base catalyzed production of biodiesel (FAME) from sunflower oil and methanol in a continuous centrifugal contactor separator (CCS) with integrated reaction and phase separation was studied. The effect of catalyst loading (sodium methoxide), temperature, rotational frequency and flow rates of th

  19. Biodiesel synthesis from Jatropha curcas L. oil and ethanol in a continuous centrifugal contactor separator

    NARCIS (Netherlands)

    Abduh, Muhammad Yusuf; van Ulden, Wouter; Kalpoe, Vijay; van de Bovenkamp, Hendrik H.; Manurung, Robert; Heeres, Hero J.

    2013-01-01

    The synthesis of fatty acid ethyl esters (FAEE) from Jatropha curcas L. oil was studied in a batch reactor and a continuous centrifugal contactor separator (CCCS) using sodium ethoxide as the catalyst. The effect of relevant process variables like rotational speed, temperature, catalyst concentratio

  20. Centrifugal pyrocontactor

    Science.gov (United States)

    Chow, Lorac S.; Leonard, Ralph A.

    1993-01-01

    A method for mixing and separating immiscible liquid salts and liquid metals in a centrifugal contractor. The method includes introducing the liquids into an annular mixing zone and intensely mixing the liquids using vertical vanes attached to a rotor cooperating with vertical baffles, a horizontal baffle, and bottom vanes attached to the contactor housing. The liquids enter the contactor in the range of 700-800 degrees Celsius. The liquids are separated in the rotor into a dense phase and a light phase which are discharged from the contactor.

  1. Towards an optimized flow-sheet for a SANEX demonstration process using centrifugal contactors

    Energy Technology Data Exchange (ETDEWEB)

    Magnusson, D. [European Commission, Joint Research Center, Karlsruhe (Germany). Inst. for Transuranium Elements; Chalmers Univ. of Technology, Gothenburg (Sweden). Nuclear Chemistry, Dept. of Chemical and Biological Engineering; Christiansen, B.; Glatz, J.P.; Malmbeck, R.; Serrano-Purroy, D. [European Commission, Joint Research Center, Karlsruhe (Germany). Inst. for Transuranium Elements; Modolo, G. [Forschungszentrum Juelich GmbH (Germany). Inst. for Energy Research, Safety Research and Reactor Technology; Sorel, C. [Commissariat a l' Energie Atomique Valrho (CEA), DRCP/SCPS, Bagnols-sur-Ceze (France)

    2009-07-01

    The design of an efficient process flow-sheet requires accurate extraction data for the experimental set-up used. Often this data is provided as equilibrium data. Due to the small hold-up volume compared to the flow rate in centrifugal contactors the time for extraction is often too short to reach equilibrium D-ratios. In this work single stage kinetics experiments have been carried out to investigate the D-ratio dependence of the flow rate and to compare this with equilibrium batch experiments for a SANEX system based on CyMe{sub 4}-BTBP. The first centrifuge experiment was run with spiked solutions while in the second a genuine actinide/lanthanide fraction from a TODGA process was used. Three different flow rates were tested with each set-up. The results show that even with low flow rates, only around 9% of the equilibrium D-ratio (Am) was reached for the extraction in the spiked test and around 16% in the hot test (the difference is due to the size of the centrifuges). In the hot test the lanthanide scrubbing was inefficient whereas in the stripping both the actinides and the lanthanides showed good results. Based on these results improvements of the suggested flow-sheet is discussed. (orig.)

  2. Centrifugal contactor modified for end stage operation in a multistage system

    Science.gov (United States)

    Jubin, Robert T.

    1990-01-01

    A cascade formed of a plurality of centrifugal contactors useful for countercurrent solvent extraction processes such as utilizable for the reprocessing of nuclear reactor fuels is modified to permit operation in the event one or both end stages of the cascade become inoperative. Weir assemblies are connected to each of the two end stages by suitable conduits for separating liquids discharged from an inoperative end stage based upon the weight of the liquid phases uses in the solvent extraction process. The weir assembly at one end stage is constructed to separate and discharge the heaviest liquid phase while the weir assembly at the other end stage is constructed to separate and discharge the lightest liquid phase. These weir assemblies function to keep the liquid discharge from an inoperative end stages on the same weight phase a would occur from an operating end stage.

  3. Mass Transfer Testing of a 12.5-cm Rotor Centrifugal Contactor

    International Nuclear Information System (INIS)

    TRUEX mass transfer tests were performed using a single stage commercially available 12.5 cm centrifugal contactor and stable cerium (Ce) and europium (Eu). Test conditions included throughputs ranging from 2.5 to 15 Lpm and rotor speeds of 1750 and 2250 rpm. Ce and Eu extraction forward distribution coefficients ranged from 13 to 19. The first and second stage strip back distributions were 0.5 to 1.4 and .002 to .004, respectively, throughout the dynamic test conditions studied. Visual carryover of aqueous entrainment in all organic phase samples was estimated at < 0.1 % and organic carryover into all aqueous phase samples was about ten times less. Mass transfer efficiencies of = 98 % for both Ce and Eu in the extraction section were obtained over the entire range of test conditions. The first strip stage mass transfer efficiencies ranged from 75 to 93% trending higher with increasing throughput. Second stage mass transfer was greater than 99% in all cases. Increasing the rotor speed from 1750 to 2250 rpm had no significant effect on efficiency for all throughputs tested

  4. Mass Transfer Testing of a 12.5-cm Rotor Centrifugal Contactor

    Energy Technology Data Exchange (ETDEWEB)

    D. H. Meikrantz; T. G. Garn; J. D. Law; N. R. Mann; T. A. Todd

    2008-09-01

    TRUEX mass transfer tests were performed using a single stage commercially available 12.5 cm centrifugal contactor and stable cerium (Ce) and europium (Eu). Test conditions included throughputs ranging from 2.5 to 15 Lpm and rotor speeds of 1750 and 2250 rpm. Ce and Eu extraction forward distribution coefficients ranged from 13 to 19. The first and second stage strip back distributions were 0.5 to 1.4 and .002 to .004, respectively, throughout the dynamic test conditions studied. Visual carryover of aqueous entrainment in all organic phase samples was estimated at < 0.1 % and organic carryover into all aqueous phase samples was about ten times less. Mass transfer efficiencies of = 98 % for both Ce and Eu in the extraction section were obtained over the entire range of test conditions. The first strip stage mass transfer efficiencies ranged from 75 to 93% trending higher with increasing throughput. Second stage mass transfer was greater than 99% in all cases. Increasing the rotor speed from 1750 to 2250 rpm had no significant effect on efficiency for all throughputs tested.

  5. Hydraulic forces caused by annular pressure seals in centrifugal pumps

    Science.gov (United States)

    Iino, T.; Kaneko, H.

    1980-01-01

    The hydraulic forces caused by annular pressure seals were investigated. The measured inlet and exit loss coefficients of the flow through the seals were much smaller than the conventional values. The results indicate that the damping coefficient and the inertia coefficient of the fluid film in the seal are not affected much by the rotational speed or the eccentricity of the rotor, though the stiffness coefficient seemed to be influenced by the eccentricity.

  6. Fluid-Structure Interaction Analysis on Turbulent Annular Seals of Centrifugal Pumps during Transient Process

    Directory of Open Access Journals (Sweden)

    Qinglei Jiang

    2011-01-01

    Full Text Available The current paper studies the influence of annular seal flow on the transient response of centrifugal pump rotors during the start-up period. A single rotor system and three states of annular seal flow were modeled. These models were solved using numerical integration and finite difference methods. A fluid-structure interaction method was developed. In each time step one of the three annular seal models was chosen to simulate the annular seal flow according to the state of rotor systems. The objective was to obtain a transient response of rotor systems under the influence of fluid-induced forces generated by annular seal flow. This method overcomes some shortcomings of the traditional FSI method by improving the data transfer process between two domains. Calculated results were in good agreement with the experimental results. The annular seal was shown to have a supportive effect on rotor systems. Furthermore, decreasing the seal clearance would enhance this supportive effect. In the transient process, vibration amplitude and critical speed largely changed when the acceleration of the rotor system increased.

  7. A New Approach to Designing the S-Shaped Annular Duct for Industrial Centrifugal Compressor

    Directory of Open Access Journals (Sweden)

    Ivan Yurko

    2014-01-01

    Full Text Available The authors propose an analytical method for designing the inlet annular duct for an industrial centrifugal compressor using high-order Bezier curves. Using the design of experiments (DOE theory, the three-level full factorial design was developed for determination of influence of the dimensionless geometric parameters on the output criteria. Numerical research was carried out for determination of pressure loss coefficients and velocity swirl angles using the software system ANSYS CFX. Optimal values of the slope for a wide range of geometric parameters, allowing minimizing losses in the duct, have been found. The study has used modern computational fluid dynamics techniques to develop a generalized technique for future development of efficient variable inlet guide vane systems. Recommendations for design of the s-shaped annular duct for industrial centrifugal compressor have been given.

  8. A New Approach to Designing the S-Shaped Annular Duct for Industrial Centrifugal Compressor

    OpenAIRE

    Ivan Yurko; German Bondarenko

    2014-01-01

    The authors propose an analytical method for designing the inlet annular duct for an industrial centrifugal compressor using high-order Bezier curves. Using the design of experiments (DOE) theory, the three-level full factorial design was developed for determination of influence of the dimensionless geometric parameters on the output criteria. Numerical research was carried out for determination of pressure loss coefficients and velocity swirl angles using the software system ANSYS CFX. Optim...

  9. Experimental and modelling studies on continuous synthesis and refining of biodiesel in a dedicated bench scale unit using centrifugal contactor separator technology

    NARCIS (Netherlands)

    Abduh, Muhammad Yusuf; Martinez, Alberto Fernandez; Kloekhorst, Arjan; Manurung, Robert; Heeres, Hero J.

    2016-01-01

    Continuous synthesis and refining of biodiesel (FAME) using a laboratory scale bench scale unit was explored. The unit consists of three major parts: (i) a continuous centrifugal contactor separator (CCCS) to perform the reaction between sunflower oil and methanol; (ii) a washing unit for the crude

  10. Fractional reactive extraction for symmetrical separation of 4-nitro-D,L-phenylalanine in centrifugal contactor separators: experiments and modeling.

    Science.gov (United States)

    Tang, Kewen; Wen, Ping; Zhang, Panliang; Huang, Yan

    2015-01-01

    The enantioselective liquid-liquid extraction of 4-nitro-D,L-phenylalanine (D,L-Nphy) using PdCl2 {(s)-BINAP} as extractant in dichloroethane was studied experimentally in a countercurrent cascade of 10 centrifugal contactor separators (CCSs) at 5°C, involving flow ratio, extractant concentration, and Cl(-) concentration. The steady-state enantiomeric excess (ee) in both stream exits was 90.86% at a 93.29% yield. The predicted value was modeled using an equilibrium stage approach. The correlation between model and experiment was satisfactory. The model was applied to optimize the production of both enantiomers in >97% ee and >99% ee. 14 stages and 16 stages are required for 97% ee and 99% ee for both enantiomers, respectively.

  11. The effect of inlet swirl on the dynamics of long annular seals in centrifugal pumps

    Science.gov (United States)

    Ismail, M.; Brown, R. D.; France, D.

    1994-01-01

    This paper describes additional results from a continuing research program which aims to identify the dynamics of long annular seals in centrifugal pumps. A seal test rig designed at Heriot-Watt University and commissioned at Weir Pumps Research Laboratory in Alloa permits the identification of mass, stiffness, and damping coefficients using a least-squares technique based on the singular value decomposition method. The analysis is carried out in the time domain using a multi-fiequency forcing function. The experimental method relies on the forced excitation of a flexibly supported stator by two hydraulic shakers. Running through the stator embodying two symmetrical balance drum seals is a rigid rotor supported in rolling element bearings. The only physical connection between shaft and stator is the pair of annular gaps filled with pressurized water discharged axially. The experimental coefficients obtained from the tests are compared with theoretical values.

  12. Annular Seals of High Energy Centrifugal Pumps: Presentation of Full Scale Measurement

    Science.gov (United States)

    Florjancic, S.; Stuerchler, R.; Mccloskey, T.

    1991-01-01

    Prediction of rotordynamic behavior for high energy concentration centrifugal pumps is a challenging task which still imposes considerable difficulties. While the mechanical modeling of the rotor is solved most satisfactorily by finite element techniques, accurate boundary conditions for arbitrary operating conditions are known for journal bearings only. Little information is available on the reactive forces of annular seals, such as neck ring and interstage seals and balance pistons, and on the impeller interaction forces. The present focus is to establish reliable boundary conditions at annular seals. For this purpose, a full scale test machine was set up and smooth and serrated seal configurations measured. Dimensionless coefficients are presented and compared with a state of the art theory.

  13. Recent advances of annular centrifugal extractor for hot test of nuclear waste partitioning process

    Institute of Scientific and Technical Information of China (English)

    HeXiang-Ming; YanYu-Shun; 等

    1998-01-01

    Advances are being made in the design of the annular centrifugal extractor fornuclear fuel reprocessing extraction process studies.The extractors have been built and tested.Twelve stages of this extractor and 50 stages are used toimplement the TRPO process for the cleanup ofcommercial and defense nuclear waste liquids,respectively.Following advances are available:(1) simple way of assembly and disassembly between rotor part and housing part of extractor,ease of manipulator operation;(2)automatic sampling from housing of extractor in hot cell;(3) compact multi-stage housing system;(4) easy interstage link;(5) computer data acquisition and monitoring system of speed.

  14. Evaluation of an alkaline-side solvent extraction process for cesium removal from SRS tank waste using laboratory-scale centrifugal contactors

    International Nuclear Information System (INIS)

    An alkaline-side solvent extraction process for cesium removal from Savannah River Site (SRS) tank waste was evaluated experimentally using a laboratory-scale centrifugal contactor. Single-stage and multistage tests were conducted with this contactor to determine hydraulic performance, stage efficiency, and general operability of the process flowsheet. The results and conclusions of these tests are reported along with those from various supporting tests. Also discussed is the ability to scale-up from laboratory- to plant-scale operation when centrifugal contractors are used to carry out the solvent extraction process. While some problems were encountered, a promising solution for each problem has been identified. Overall, this alkaline-side cesium extraction process appears to be an excellent candidate for removing cesium from SRS tank waste

  15. Numerical simulation on dimension decrease for annular casing of one centrifugal boiler circulation pump

    International Nuclear Information System (INIS)

    Primary formulation derivation indicates that the dimension of one existing centrifugal boiler circulation pump casing is too large. As great manufacture cost can be saved by dimension decrease, a numerical simulation research is developed in this paper on dimension decrease for annular casing of this pump with a specific speed equaling to 189, which aims at finding an appropriately smaller dimension of the casing while hydraulic performance and strength performance will hardly be changed according to the requirements of the cooperative company. The research object is one existing centrifugal pump with a diffuser and a semi-spherical annular casing, working as the boiler circulation pump for (ultra) supercritical units in power plants. Dimension decrease, the modification method, is achieved by decreasing the existing casing's internal radius (marked as Ri0) while keeping the wall thickness. The research analysis is based on primary formulation derivation, CFD (Computational Fluid Dynamics) simulation and FEM (Finite Element Method) simulation. Primary formulation derivation estimates that a design casing's internal radius should be less than 0.75 Ri0. CFD analysis indicates that smaller casing with 0.75 Ri0 has a worse hydraulic performance when working at large flow rates and a better hydraulic performance when working at small flow rates. In consideration of hydraulic performance and dimension decrease, an appropriate casing's internal radius is determined, which equals to 0.875 Ri0. FEM analysis then confirms that modified pump casing has nearly the same strength performance as the existing pump casing. It is concluded that dimension decrease can be an economical method as well as a practical method for large pumps in engineering fields.

  16. Demonstration of a SANEX Process in Centrifugal Contactors using the CyMe{sub 4}-BTBP Molecule on a Genuine Fuel Solution

    Energy Technology Data Exchange (ETDEWEB)

    Magnusson, D.; Christiansen, B.; Glatz, J.P.; Malmbeck, R.; Serrano-Purroy, D. [European Commiss, Joint Res Ctr, Inst Transuranium Elements, D-76125 Karlsruhe, (Germany); Foreman, M.R.S. [Univ Reading, Dept Chem, Reading RG6 6AD, Berks, (United Kingdom); Geist, A. [Forschungszentrum Karlsruhe, Inst Nukl Entsorgung, D-76021 Karlsruhe, (Germany); Modolo, G. [Forschungszentrum Julich, Inst Energy Res Safety Res and Reactor Technol, D-52425 Julich, (Germany); Sorel, C. [Commissariat Energie Atom Valrho, CEA, DRCP SCPS, F-30207 Bagnols Sur Ceze, (France)

    2009-07-01

    Efficient recovery of minor actinides from a genuine spent fuel solution has been successfully demonstrated by the CyMe{sub 4}-BTBP/DMDOHEMA extractant mixture dissolved in octanol. The continuous countercurrent process, in which actinides(III) were separated from lanthanides(III), was carried out in laboratory centrifugal contactors using an optimized flow-sheet involving a total of 16 stages. The process was divided into 9 stages for extraction from a 2 M nitric acid feed solution, 3 stages for lanthanide scrubbing, and 4 stages for actinide back-extraction. Excellent feed decontamination factors for Am (7000) and Cm (1000) were obtained and the recoveries of these elements were higher than 99.9%. More than 99.9% of the lanthanides were directed to the raffinate except Gd for which 0.32% was recovered in the product. (authors)

  17. Experimental and Model Studies on Continuous Separation of 2-Phenylpropionic Acid Enantiomers by Enantioselective Liquid-Liquid Extraction in Centrifugal Contactor Separators.

    Science.gov (United States)

    Feng, Xiaofeng; Tang, Kewen; Zhang, Pangliang; Yin, Shuangfeng

    2016-03-01

    Multistage enantioselective liquid-liquid extraction (ELLE) of 2-phenylpropionic acid (2-PPA) enantiomers using hydroxypropyl-β-cyclodextrin (HP-β-CD) as extractant was studied experimentally in a counter-current cascade of centrifugal contactor separators (CCSs). Performance of the process was evaluated by purity (enantiomeric excess, ee) and yield (Y). A multistage equilibrium model was established on the basis of single-stage model for chiral extraction of 2-PPA enantiomers and the law of mass conservation. A series of experiments on the extract phase/washing phase ratio (W/O ratio), extractant concentration, the pH value of aqueous phase, and the number of stages was conducted to verify the multistage equilibrium model. It was found that model predictions were in good agreement with the experimental results. The model was applied to predict and optimize the symmetrical separation of 2-PPA enantiomers. The optimal conditions for symmetric separation involves a W/O ratio of 0.6, pH of 2.5, and HP-β-CD concentration of 0.1 mol L(-1) at a temperature of 278 K, where eeeq (equal enantiomeric excess) can reach up to 37% and Yeq (equal yield) to 69%. By simulation and optimization, the minimum number of stages was evaluated at 98 and 106 for eeeq > 95% and eeeq > 97%.

  18. Integrated AMP-PAN, TRUEX, and SREX Flowsheet Test to Remove Cesium, Surrogate Actinide Elements, and Strontium from INEEL Tank Waste Using Sorbent Columns and Centrifugal Contactors

    Energy Technology Data Exchange (ETDEWEB)

    Herbst, Ronald Scott; Law, Jack Douglas; Todd, Terry Allen; Wood, D. J.; Garn, Troy Gerry; Wade, Earlen Lawrence

    2000-02-01

    Three unit operations for the removal of selected fission products, actinides, and RCRA metals (mercury and lead) have been successfully integrated and tested for extended run times with simulated INEEL acidic tank waste. The unit operations were ion exchange for Cs removal, followed by TRUEX solvent extraction for Eu (actinide surrogate), Hg, and Re (Tc surrogate) removal, and subsequent SREX solvent extraction for Sr and Pb removal. Approximately 45 L of simulated INTEC tank waste was first processed through three ion exchange columns in series for selective Cs removal. The columns were packed with a composite ammonium molybdophosphate-polyacrylonitrile (AMP-PAN) sorbent. The experimental breakthrough data were in excellent agreement with modeling predictions based on data obtained with much smaller columns. The third column (220 cm3) was used for polishing and Cs removal after breakthrough of the up-stream columns. The Cs removal was >99.83% in the ion exchange system without interference from other species. Most of the effluent from the ion exchange (IX) system was immediately processed through a TRUEX solvent extraction flowsheet to remove europium (americium surrogate), mercury and rhenium (technetium surrogate) from the simulated waste. The TRUEX flowsheet test was performed utilizing 23 stages of 3.3-cm centrifugal contactors. Greater than 99.999% of the Eu, 96.3% of the Hg, and 56% of the Re were extracted from the simulated feed and recovered in the strip and wash streams. Over the course of the test, there was no detectable build-up of any components in the TRUEX solvent. The raffinate from the TRUEX test was stored and subsequently processed several weeks later through a SREX solvent extraction flowsheet to remove strontium, lead, and Re (Tc surrogate) from the simulated waste. The SREX flowsheet test was performed using the same centrifugal contactors used in the TRUEX test after reconfiguration and the addition of three stages. Approximately 99.9% of

  19. FLUID CONTACTOR APPARATUS

    Science.gov (United States)

    Spence, R.; Streeton, R.J.W.

    1956-04-17

    The fluid contactor apparatus comprises a cylindrical column mounted co- axially and adapted to rotate within a cylindrical vessel, for the purpose of extracting a solute from am aqueous solution by means of an organic solvent. The column is particularly designed to control the vortex pattern so as to reduce the height of the vortices while, at the same time, the width of the annular radius in the radial direction between the vessel and column is less than half the radius of the column. A plurality of thin annular fins are spaced apart along the rotor approximately twice the radial dimension of the column such that two contrarotating substantially circular vortices are contained within each pair of fins as the column is rotated.

  20. Membrane contactor applications

    NARCIS (Netherlands)

    Klaassen, R.; Feron, P.H.M.; Jansen, A.

    2008-01-01

    In a membrane contactor the membrane separation is completely integrated with an extraction or absorption operation in order to exploit the benefits of both technologies fully. Membrane contactor applications that have been developed can be found in both water and gas treatment. Several recently dev

  1. Annular pancreas

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/001142.htm Annular pancreas To use the sharing features on this page, please enable JavaScript. An annular pancreas is a ring of pancreatic tissue that encircles ...

  2. Identification And Characterization Of The Solids Found In Extraction Contactor SEP-401 In June 2012

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F. F.; Fink, S. D.

    2012-12-10

    The Modular Caustic-Side Solvent Extraction Unit (MCU) recently conducted an outage that included maintenance on the centrifugal contactors. Operations personnel observed solids or deposits in two contactors and attempted to collect samples for analyses by Savannah River National Laboratory (SRNL). The residues found in Extraction Contactor SEP-401 are a mixture of amorphous silica, aluminosilicate, titanium, and debris from low alloy steel. The solids contain low concentrations of plutonium and strontium. These isotopes are associated with the titanium that came from the monosodium titanate (MST) added in the Actinide Removal Process (ARP) most likely as leached Ti from the MST that precipitated subsequently in MCU. An attempt was also made to obtain samples from the contents of Wash Contactor SEP-702. However, sampling provide ineffective.

  3. Contactor/filter improvements

    Science.gov (United States)

    Stelman, David

    1989-01-01

    A contactor/filter arrangement for removing particulate contaminants from a gaseous stream includes a housing having a substantially vertically oriented granular material retention member with upstream and downstream faces, a substantially vertically oriented microporous gas filter element, wherein the retention member and the filter element are spaced apart to provide a zone for the passage of granular material therethrough. The housing further includes a gas inlet means, a gas outlet means, and means for moving a body of granular material through the zone. A gaseous stream containing particulate contaminants passes through the gas inlet means as well as through the upstream face of the granular material retention member, passing through the retention member, the body of granular material, the microporous gas filter element, exiting out of the gas outlet means. Disposed on the upstream face of the filter element is a cover screen which isolates the filter element from contact with the moving granular bed and collects a portion of the particulates so as to form a dust cake having openings small enough to exclude the granular material, yet large enough to receive the dust particles. In one embodiment, the granular material is comprised of prous alumina impregnated with CuO, with the cover screen cleaned by the action of the moving granular material as well as by backflow pressure pulses.

  4. [Granuloma annulare].

    Science.gov (United States)

    Butsch, F; Weidenthaler-Barth, B; von Stebut, E

    2015-11-01

    Granuloma annulare is a benign, chronic inflammatory skin disease. Its pathogenesis is still unclear, but reports on infections as a trigger can be found. In addition, some authors reported an association with other systemic disease, e.g., cancer, trauma, and diabetes mellitus; however, these have not been verified. The clinical picture of granuloma annulare ranges from the localized form predominantly at the extremities to disseminated, subcutaneous, or perforating forms. Diagnosis is based on the typical clinical presentation which may be confirmed by a biopsy. Histologically, necrobiotic areas within granulomatous inflammation are typical. The prognosis of the disease is good with spontaneous resolution being frequently observed, especially in localized forms. Disseminated manifestations tend to persist longer, and recurrences are reported. When choosing between different therapeutic options, the benign disease character versus the individual degree of suffering and the potential therapy side effects must be considered. For local treatment, topical application of corticosteroids is most common. Disseminated forms can be treated systemically with corticosteroids for several weeks; alternatively, dapsone, hydroxychloroquine, retinoids, fumaric acid, cyclosporine, and anti-TNFα appear to be effective. PMID:26487494

  5. Electric vehicle drive train with contactor protection

    Science.gov (United States)

    Konrad, Charles E.; Benson, Ralph A.

    1994-01-01

    A drive train for an electric vehicle includes a traction battery, a power drive circuit, a main contactor for connecting and disconnecting the traction battery and the power drive circuit, a voltage detector across contacts of the main contactor, and a controller for controlling the main contactor to prevent movement of its contacts to the closed position when the voltage across the contacts exceeds a predetermined threshold, to thereby protect the contacts of the contactor. The power drive circuit includes an electric traction motor and a DC-to-AC inverter with a capacitive input filter. The controller also inhibits the power drive circuit from driving the motor and thereby discharging the input capacitor if the contacts are inadvertently opened during motoring. A precharging contactor is controlled to charge the input filter capacitor prior to closing the main contactor to further protect the contacts of the main contactor.

  6. ENGINEERING BULLETIN: ROTATING BIOLOGICAL CONTACTORS

    Science.gov (United States)

    Rotating biological contactors employ aerobic fixed-film treatment to degrade either organic and/or nitrogenous (ammonia-nitrogen) constituents present in aqueous waste streams. ixed-film systems provide a surface to which the biomass can adhere. Treatment is achieved as the wast...

  7. Annular Flow Distribution test

    International Nuclear Information System (INIS)

    This report documents the Babcock and Wilcox (B ampersand W) Annular Flow Distribution testing for the Savannah River Laboratory (SRL). The objective of the Annular Flow Distribution Test Program is to characterize the flow distribution between annular coolant channels for the Mark-22 fuel assembly with the bottom fitting insert (BFI) in place. Flow rate measurements for each annular channel were obtained by establishing ''hydraulic similarity'' between an instrumented fuel assembly with the BFI removed and a ''reference'' fuel assembly with the BFI installed. Empirical correlations of annular flow rates were generated for a range of boundary conditions

  8. Return Vane Installed in Multistage Centrifugal Pump

    OpenAIRE

    Miyano, Masafumi; Kanemoto, Toshiaki; Kawashima, Daisuke; Wada, Akihiro; Hara, Takashi; Sakoda, Kazuyuki

    2008-01-01

    To optimize the stationary components in the multistage centrifugal pump, the effects of the return vane profile on the performances of the multistage centrifugal pump were investigated experimentally, taking account of the inlet flow conditions for the next stage impeller. The return vane, whose trailing edge is set at the outer wall position of the annular channel downstream of the vane and which discharges the swirl-less flow, gives better pump performances. By equipping such return vane w...

  9. Effects of solvent-extraction contactor selection on flowsheet and facility design

    International Nuclear Information System (INIS)

    The notion is developed that the selection of a solvent extraction contactor is part of a more general development of principles and philosophy guiding the overall plant design. Specifically, the requirements and constraints placed on the plant by the solvent extraction system must be consistent with those imposed by the other operations, which generally are more expensive and more complicated. Were a conservative philosophy employed throughout the plant, the choice of pulsed columns seem correct. Were the plant intended to employ modern techniques and state-of-the-art technology, particularly in remote maintenance and process control, the selection of centrifugal contactors seems appropriate. The process improvements attainable from employing more stages in a more tightly controlled solvent extraction system seem marginal at present when applied to conventional flowsheets, although the cost-benefit may be attractive in a modern plant. The potential for improvement through major flowsheet modification can not presently be assessed quantitatively

  10. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  11. CENTRIFUGAL SEPARATORS

    Science.gov (United States)

    Skarstrom, C.

    1959-03-10

    A centrifugal separator is described for separating gaseous mixtures where the temperature gradients both longitudinally and radially of the centrifuge may be controlled effectively to produce a maximum separation of the process gases flowing through. Tbe invention provides for the balancing of increases and decreases in temperature in various zones of the centrifuge chamber as the result of compression and expansions respectively, of process gases and may be employed effectively both to neutralize harmful temperature gradients and to utilize beneficial temperaturc gradients within the centrifuge.

  12. Subcutaneous granuloma annulare

    Directory of Open Access Journals (Sweden)

    Dhar Sandipan

    1994-01-01

    Full Text Available Two cases of subcutaneos granuloma annulare are reported. Clinical presentation was in the form of hard subcutaneous nodules; histopathology confirmed the clinical diagnosis. The cases were unique because of onset in adult hood, occurrence over unusual sites and absence of classical lesions of granuloma annulare elsewhere.

  13. Subcutaneous granuloma annulare

    Directory of Open Access Journals (Sweden)

    Dhar Sandipan

    1993-01-01

    Full Text Available Two cases of subcutaneous granuloma annulare are reported. Clinical presentation was in the form of hard subcutaneous nodules, histopathology confirmed the clinical diagnosis. The cases were unique because of onset in adult age, occurrence over unusual sites and absence of classical lesions of granuloma annulare elsewhere.

  14. Annular pancreas (image)

    Science.gov (United States)

    Annular pancreas is an abnormal ring or collar of pancreatic tissue that encircles the duodenum (the part of the ... intestine that connects to stomach). This portion of pancreas can constrict the duodenum and block or impair ...

  15. Study on reliability technology of contactor relay

    Institute of Scientific and Technical Information of China (English)

    LIU Guo-jin; ZHAO Jing-ying; WANG Hai-tao; YANG Chen-guang; SUN Shun-li

    2007-01-01

    In this paper, the reliability of contactor relay is studied. There are three main parts about reliability test and analysis. First, in order to analyze reliability level of contact relay, the failure ratio ranks are established as index base on the product level. Second, the reliability test method is put forward. The sample plan of reliability compliance test is gained from reliability sample theory. The failure criterion is ensured according to the failure modes of contactor relay. Third, after reliability test experiment, the analysis of failure physics is made and the failure reason is found.

  16. Centrifugally activated bearing for high-speed rotating machinery

    Science.gov (United States)

    Post, Richard F.

    1994-01-01

    A centrifugally activated bearing is disclosed. The bearing includes an annular member that extends laterally and radially from a central axis. A rotating member that rotates about the central axis relative to the annular member is also included. The rotating member has an interior chamber that surrounds the central axis and in which the annular member is suspended. Furthermore, the interior chamber has a concave shape for retaining a lubricant therein while the rotating member is at rest and for retaining a lubricant therein while the rotating member is rotating. The concave shape is such that while the rotating member is rotating a centrifugal force causes a lubricant to be forced away from the central axis to form a cylindrical surface having an axis collinear with the central axis. This centrifugally displaced lubricant provides restoring forces to counteract lateral displacement during operation.

  17. Micro contactor based on isotachophoretic sample transport.

    Science.gov (United States)

    Goet, Gabriele; Baier, Tobias; Hardt, Steffen

    2009-12-21

    It is demonstrated how isotachophoresis (ITP) in a microfluidic device may be utilized to bring two small sample volumes into contact in a well-controlled manner. The ITP contactor serves a similar purpose as micromixers that are designed to mix two species rapidly in a microfluidic channel. In contrast to many micromixers, the ITP contactor does not require complex channel architectures and allows a sample processing in the spirit of "digital microfluidics", i.e. the samples always remain in a compact volume. It is shown that the ITP zone transport through microchannels proceeds in a reproducible and predictable manner, and that the sample trajectories follow simple relationships obtained from Ohm's law. Firstly, the micro contactor can be used to synchronize two ITP zones having reached a channel at different points in time. Secondly, fulfilling its actual purpose it is capable of bringing two samples in molecular contact via an interpenetration of ITP zones. It is demonstrated that the contacting time is proportional to the ITP zone extension. This opens up the possibility of using that type of device as a special type of micromixer with "mixing times" significantly below one second and an option to regulate the duration of contact through specific parameters such as the sample volume. Finally, it is shown how the micro contactor can be utilized to conduct a hybridization reaction between two ITP zones containing complementary DNA strands.

  18. Thermal Simulation of AC Electromagnetic Contactor

    Institute of Scientific and Technical Information of China (English)

    NIUChun-ping; CHENDe-gui; ZHANGJing-shu; LIXing-wen

    2005-01-01

    Transient magnetic circuit method is adopted to calculate the power loss in winding and shading coil. Based on the analysis of heat transfer process in AC contactor, a thermal model is proposed and the temperature field distribution is simulated with 3-D FEM of ANSYS.Comparison of simulation results with measurements shows that the proposed method is effective.

  19. Characterization of fouling of membrane contactors

    DEFF Research Database (Denmark)

    Ciurkot, Kaludia; Zarebska, Agata; Christensen, Knud Villy

    2013-01-01

    In this study liquid-liquid membrane contactors have been tested for ammonia removal from model manure solution and undigested pig manure. The aim of this work is to compare the efficiency of ammonia removal by different hydrophobic membranes including the material’s influence on mass transfer...

  20. Continuous fluidized-bed contactor with recycle of sorbent

    Science.gov (United States)

    Scott, Charles D.; Petersen, James N.; Davison, Brian H.

    1996-01-01

    A continuous fluidized-bed contactor containing sorbent particles is used to remove solutes from liquid solvents. As the sorbent particles, for example gel beads, sorb the solute, for example metal ion species, the sorbent particles tend to decrease in diameter. These smaller loaded sorbent particles rise to the top of the contactor, as larger sorbent particles remain at the bottom of the contactor as a result of normal hydraulic forces. The smaller loaded sorbent particles are then recovered, regenerated, and reintroduced into the contactor. Alternatively, the loaded sorbent particles may also slightly increase in diameter, or exhibit no change in diameter but an increase in density. As a result of normal hydraulic forces the larger loaded sorbent particles fall to the bottom of the contactor. The larger loaded sorbent particles are then recovered, regenerated, and reintroduced into the contactor.

  1. Generalized granuloma annulare

    Directory of Open Access Journals (Sweden)

    Khatri M

    1995-01-01

    Full Text Available A 35-years-old female patient had generalized pruritic papular lesions, distributed like dermatitis herpetiformis for last 4 years. Histopathologic changes were typical of granuloma annulare with negative results of direct immunofluorescence. The patient did not have association of diabetes mellitus or any other systemic disease. She failed to respond to dapsone therapy and 13-cis-retinoic acid.

  2. Annular Planar Monopole Antennas

    OpenAIRE

    Chen, Z. N.; Ammann, Max; Chia, W.Y. W.; See, T.S. P.

    2002-01-01

    A type of annular planar monopole antenna is presented. The impedance and radiation characteristics of the monopole with different holes and feed gaps are experimentally examined. The measured results demonstrate that the proposed antenna is capable of providing significantly broad impedance bandwidth with acceptable radiation performance.

  3. Rotating biological contactors: the Canadian experience

    Energy Technology Data Exchange (ETDEWEB)

    Cuenca, Manuel A. [Ryerson Polytechnical Univ., Toronto, ON (Canada). Chemical Engineering Dept.; Smith, Tom [CMS Rotordisk Inc., Concord, ON (Canada); Vianna, Arlinda C. [Servico Nacional de Aprendizagem Industrial (SENAI), Salvador, BA (Brazil)

    1993-12-31

    In fifteen years, Rotating Biological Contactors (RBC) have become one of the most attractive technologies for secondary wastewater treatment. The present work is a review of the evolution of RBC technology in the last twenty years. In addition, the status of the technology in Canada is described, emphasizing industrial facilities and landfill leachate treatment. An enumeration of the most relevant development areas is included. (author). 34 refs., 3 figs., 7 tabs.

  4. Denitrification in anoxic rotating biological contactors

    OpenAIRE

    Teixeira, P; Oliveira, Rosário; Mota, M.

    2009-01-01

    Rotating Biological Contactors (RBCs) constitute a very unique and superior alternative for biodegradable matter and nitrogen removal on account of their feasibility, simplicity of design and operation, short start-up, low land area requirement, low energy consumption, low operating and maintenance cost and treatment efficiency, as well as easy scalability. It is well known that the performance of this type of reactors is controlled by a high number of design parameters. In thi...

  5. Desorption of trihalomethanes in gas liquid contactors

    International Nuclear Information System (INIS)

    Updated studies show that gastric cancer is related with the existence of trihalomethanes (THMs) in the drinking water. The trihalomethanes are sub products from the degradation of humic acids and your reaction with chlorine and bromine used like decontaminates. The desorption process is used to eliminate the THMs with air in contact with the water. The experimental design was used in three contactors. The contactors selected were: the bubbling's column, the packed column and the shaken tank without screen. There were selected three variable: initial concentration of THMs, the residence time and the turbulence degree (measured with the Reynolds number). The concentrations were made with a gas chromatograph. The objective of this project is to do a comparison with the gas liquid contactors more used in the industrial level to determinate which ones are the best in the desorption process. The conclusion of the experimental design is that the tank is the equipment with the best capacity to eliminate THMs. Too it includes other techniques to eliminate THMs of the water and your treatment

  6. Hollow fiber membrane contactor as a gas–liquid model contactor

    NARCIS (Netherlands)

    Dindore, V.Y.; Brilman, D.W.F.; Versteeg, G.F.

    2005-01-01

    Microporous hollow fiber gas–liquid membrane contactors have a fixed and well-defined gas–liquid interfacial area. The liquid flow through the hollow fiber is laminar, thus the liquid side hydrodynamics are well known. This allows the accurate calculation of the fiber side physical mass transfer coe

  7. Hollow fiber membrane contactor as a gas-liquid model contactor

    NARCIS (Netherlands)

    Dindore, V. Y.; Brilman, D. W. F.; Versteeg, G. F.

    2005-01-01

    Microporous hollow fiber gas-liquid membrane contactors have a fixed and well-defined gas-liquid interfacial area. The liquid flow through the hollow fiber is laminar, thus the liquid side hydrodynamics are well known. This allows the accurate calculation of the fiber side physical mass transfer coe

  8. Centrifugal pumps

    CERN Document Server

    Gülich, Johann Friedrich

    2014-01-01

    This book gives an unparalleled, up-to-date, in-depth treatment of all kinds of flow phenomena encountered in centrifugal pumps including the complex interactions of fluid flow with vibrations and wear of materials. The scope includes all aspects of hydraulic design, 3D-flow phenomena and partload operation, cavitation, numerical flow calculations, hydraulic forces, pressure pulsations, noise, pump vibrations (notably bearing housing vibration diagnostics and remedies), pipe vibrations, pump characteristics and pump operation, design of intake structures, the effects of highly viscous flows, pumping of gas-liquid mixtures, hydraulic transport of solids, fatigue damage to impellers or diffusers, material selection under the aspects of fatigue, corrosion, erosion-corrosion or hydro-abrasive wear, pump selection, and hydraulic quality criteria. As a novelty, the 3rd ed. brings a fully analytical design method for radial impellers, which eliminates the arbitrary choices inherent to former design procedures. The d...

  9. Uranium recovery from assorted laboratory organic waste solutions using centrifugal contractors

    International Nuclear Information System (INIS)

    Countercurrent extraction runs, carried out in our laboratory for the evaluation studies of N,N-dihexyloctanamide (DHOA) as an alternative of tributyl phosphate (TBP) for spent fuel reprocessing, have led to generation of large volumes of organic wastes containing varying amounts of uranium. It was desirable to recover uranium from such waste solutions prior to the disposal of organic waste solutions. Even though, batch stripping can be used for this purpose, it may take several days to achieve the desired goal. In this context, the centrifugal contactors appear attractive due to high liquid through-put, which may simplify the uranium recovery process. Uranium recovery studies from assorted organic waste solutions were therefore carried out using centrifugal contactors

  10. [Disseminated granuloma annulare].

    Science.gov (United States)

    Kansky, A

    1975-09-01

    A case of generalized granuloma annulare in a 55 year old man is reported. The disease appeared five years before the first admission to the hospital. A large number of bluish-red or skin-colour papules were scattered mainly around the earlobes, buttocks and on the extremities. Some of the lesions were lined up in rings or plaques. Small depigmented and brownish scars were present. Two biopsies revealed characteristic foci of complete collagen degeneration accompanied by a palisading infiltrate in the upper dermis. Treatment with tuberculostatics and antimalarics was without improvement. The lesions cleared after a course of prednison, but reappeared when the drug was discontinued.

  11. Annular recuperator design

    Science.gov (United States)

    Kang, Yungmo

    2005-10-04

    An annular heat recuperator is formed with alternating hot and cold cells to separate counter-flowing hot and cold fluid streams. Each cold cell has a fluid inlet formed in the inner diameter of the recuperator near one axial end, and a fluid outlet formed in the outer diameter of the recuperator near the other axial end to evenly distribute fluid mass flow throughout the cell. Cold cells may be joined with the outlet of one cell fluidly connected to the inlet of an adjacent downstream cell to form multi-stage cells.

  12. Single Stage Contactor Testing Of The Next Generation Solvent Blend

    Energy Technology Data Exchange (ETDEWEB)

    Herman, D. T.; Peters, T. B.; Duignan, M. R.; Williams, M. R.; Poirier, M. R.; Brass, E. A.; Garrison, A. G.; Ketusky, E. T.

    2014-01-06

    The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility at the Savannah River Site (SRS) is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent to increase the cesium decontamination factor. To support this integration of NGS into the MCU facility the Savannah River National Laboratory (SRNL) performed testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing utilized a blend of BOBCalixC6 based solvent and the NGS with the new extractant, MaxCalix, as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 liquid-to-liquid centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. The results indicate that hydraulically, the NGS solvent performed hydraulically similar to the current solvent which was expected. For the organic carryover 93% of the solvent is predicted to be recovered from the stripping operation and 96% from the extraction operation. As for the mass transfer, the NGS solvent significantly improved the cesium DF by at least an order of magnitude when extrapolating the One-stage results to actual Seven-stage extraction operation with a stage efficiency of 95%.

  13. Axisymmetric annular curtain stability

    International Nuclear Information System (INIS)

    A temporal stability analysis was carried out to investigate the stability of an axially moving viscous annular liquid jet subject to axisymmetric disturbances in surrounding co-flowing viscous gas media. We investigated in this study the effects of inertia, surface tension, the gas-to-liquid density ratio, the inner-to-outer radius ratio and the gas-to-liquid viscosity ratio on the stability of the jet. With an increase in inertia, the growth rate of the unstable disturbances is found to increase. The dominant (or most unstable) wavenumber decreases with increasing Reynolds number for larger values of the gas-to-liquid viscosity ratio. However, an opposite tendency for the most unstable wavenumber is predicted for small viscosity ratio in the same inertia range. The surrounding gas density, in the presence of viscosity, always reduces the growth rate, hence stabilizing the flow. There exists a critical value of the density ratio above which the flow becomes stable for very small viscosity ratio, whereas for large viscosity ratio, no stable flow appears in the same range of the density ratio. The curvature has a significant destabilizing effect on the thin annular jet, whereas for a relatively thick jet, the maximum growth rate decreases as the inner radius increases, irrespective of the surrounding gas viscosity. The degree of instability increases with Weber number for a relatively large viscosity ratio. In contrast, for small viscosity ratio, the growth rate exhibits a dramatic dependence on the surface tension. There is a small Weber number range, which depends on the viscosity ratio, where the flow is stable. The viscosity ratio always stabilizes the flow. However, the dominant wavenumber increases with increasing viscosity ratio. The range of unstable wavenumbers is affected only by the curvature effect. (paper)

  14. Low cost membrane contactors based on hollow fibres

    Directory of Open Access Journals (Sweden)

    Raudensky Miroslav

    2012-04-01

    Full Text Available Membrane contactors are used to solve different chemical engineering tasks (e.g. water saturation with gases. Such elements are traditionally used for bubble less oxidation of blood. However, their industrial applications are rather limited by their high investment costs. This is probably the main reason why membrane contactors are not used so widely, e.g. classical absorbers, etc. If potted bundles of hollow fibres are available, then it is a relatively simple task to design an ad hoc membrane contactor. However, it must be emphasised that to achieve the highest mass transfer efficiency requires a rather time-consuming tuning of each ad hoc designed contactor. To check the differences by water evaporation were aligned two modes, the water inside the hollow fibre membrane and fan air outside, next with the water outsides and flowing pressure air inside the membrane.

  15. Annular Hybrid Rocket Motor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Engineers at SpaceDev have conducted a preliminary design and analysis of a proprietary annular design concept for a hybrid motor. A U.S. Patent application has...

  16. Manufacture of annular cermet articles

    Science.gov (United States)

    Forsberg, Charles W.; Sikka, Vinod K.

    2004-11-02

    A method to produce annular-shaped, metal-clad cermet components directly produces the form and avoids multiple fabrication steps such as rolling and welding. The method includes the steps of: providing an annular hollow form with inner and outer side walls; filling the form with a particulate mixture of ceramic and metal; closing, evacuating, and hermetically sealing the form; heating the form to an appropriate temperature; and applying force to consolidate the particulate mixture into solid cermet.

  17. Centrifugal reciprocating compressor

    Science.gov (United States)

    High, W. H.

    1980-01-01

    Efficient compressor uses centrifugal force to compress gas. System incorporates two coupled dc motors, each driving separate centrifugal reciprocating-compressor assembly. Motors are synchronized to accelerate and decelerate alternately.

  18. Enrichment: centrifuge process

    International Nuclear Information System (INIS)

    This short course is divided into three sections devoted respectively to the physics of the process, some practical problems raised by the design of a centrifuge and the present situation of centrifugation in the World. 31 figs., 18 refs

  19. Centrifuge modeling of monopiles

    DEFF Research Database (Denmark)

    Klinkvort, Rasmus Tofte

    2010-01-01

    To gain a larger knowledge of the monopile foundation concept, centrifuge modeling is used by the geotechnical group at DTU. The centrifuge operated at DTU is a beam centrifuge and was built in 1976. In the recent years it has been upgraded with onboard data acquisition and control systems....... The capabilities of the centrifuge at DTU makes it possible to obtain a scale factor of 85 in experiments which equals a soil volume in prototype scale of a diameter of 40 meters and a depth of 40 meters. This paper describes centrifuge modeling theory, the centrifuge setup at DTU and as an example show results...... from centrifuge tests performed on large diameter piles installed in dry sand....

  20. Performance comparison of suspended bed and batch contactor chromatography.

    Science.gov (United States)

    Quiñones-García, I; Rayner, I; Levison, P R; Dickson, N; Purdom, G

    2001-01-26

    In some applications, the purification and recovery of biomolecules is performed via a cascade of batch adsorption and desorption stages using agitated contactors and related filtration devices. Suspended bed chromatography is a recent process-scale innovation that is applicable to these separations. This hybrid technique exploits the benefits of combining batch adsorption in an agitated contactor with elution in an enclosed column system. To some extent, the process is similar to batch contactor chromatography but can be fully contained and significantly quicker. The process has two steps; first the fluid containing the sample is mixed with the adsorbent in a stirred tank. Second, the slurry suspension is transferred directly into a specialized column, such as an IsoPak column. The media with the adsorbed product is formed as a packed bed, whilst the suspension liquid is passed out of the column. The product is then eluted from the packed bed utilizing standard column-chromatography techniques. The performance of the suspended bed and the agitated contactor operations are demonstrated both by full-scale experimental results and process simulations. The purification of ovalbumin from a hen-egg white feedstock by anion-exchange chromatography was used as a case study in order to prove the concept. With the availability of both pump-packed systems and shear-resistant media, suspended bed chromatography is a better alternative for a range of applications than the traditional batch separations using agitated contactors. PMID:11218119

  1. Adiabatic Steam-Water Annular Flow in an Annular Geometry

    DEFF Research Database (Denmark)

    Andersen, P. S.; Würtz, J.

    1981-01-01

    Experimental results for fully developed steam-water annular flow in annular geometries are presented. Rod and tube film flow rates and axial pressure gradients were measured for mass fluxes between 500 and 2000 kg/m2s, steam qualities between 20 and 60 per cent and pressures ranging from 3 to 9...... MPa. It was found that the measured tube film flow rate per unit tube perimeter is always many times greater than the corresponding rod film flow rate. Possible explanations for this asymmetry are discussed....

  2. Annular lipoatrophy of the ankles.

    Science.gov (United States)

    Dimson, Otobia G; Esterly, Nancy B

    2006-02-01

    Lipoatrophic panniculitis likely represents a group of disorders characterized by an inflammatory panniculitis followed by lipoatrophy. It occurs locally in a variety of settings and has been reported in the literature under various terms, including annular atrophic connective tissue panniculitis of the ankles, annular and semicircular lipoatrophy, abdominal lipoatrophy, and connective tissue panniculitis. Herein, a case of annular lipoatrophy of the ankles is described in a 6-year-old girl with autoimmune thyroid disease. Histologically, a mixed lobular panniculitis with lipophages was present. This pattern resembles that seen in lipoatrophic panniculitis. After a single, acute episode of an inflammatory process with subsequent lipoatrophy, her skin lesions have stabilized for 2 years requiring no treatment.

  3. Development of novel contactor for nuclear solvent extraction

    International Nuclear Information System (INIS)

    For current designs of radiochemical plants, solvent-extraction contactors with no periodic maintenance like pulse column are the first choice. In addition, as costs of specialty solvents for nuclear extraction are quite high, there is a demand for operation at extreme phase ratios. Recently a novel mixer-settler was visualized and developed for this kind of service. The mixer of the novel contactor is based on rotated helical tubes and does not involve any mechanical moving part. Mass-transfer runs were carried out with aqueous nitric acid and 30% TBP solvent at A/O of 0.25-200 (in extraction) and A/O of 0.25-10 (in back-extraction mode). The developed contactor exhibited nearly 100% efficiency for all the cases. (authors)

  4. Phase flow rate measurements of annular flows

    OpenAIRE

    Al-Yarubi, Qahtan

    2010-01-01

    In the international oil and gas industry multiphase annular flow in pipelines and wells is extremely important, but not well understood. This thesis reports the development of an efficient and cheap method for measuring the phase flow rates in two phase annular and annular mist flow, in which the liquid phase is electrically conducting, using ultrasonic and conductance techniques. The method measures changes in the conductance of the liquid film formed during annular flow and uses these to c...

  5. Eosinophilic annular erythema in childhood - Case report.

    Science.gov (United States)

    Abarzúa, Alvaro; Giesen, Laura; Silva, Sergio; González, Sergio

    2016-01-01

    Eosinophilic annular erythema is a rare, benign, recurrent disease, clinically characterized by persistent, annular, erythematous lesions, revealing histopathologically perivascular infiltrates with abundant eosinophils. This report describes an unusual case of eosinophilic annular erythema in a 3-year-old female, requiring sustained doses of hydroxychloroquine to be adequately controlled. PMID:27579748

  6. Eosinophilic annular erythema in childhood - Case report*

    Science.gov (United States)

    Abarzúa, Alvaro; Giesen, Laura; Silva, Sergio; González, Sergio

    2016-01-01

    Eosinophilic annular erythema is a rare, benign, recurrent disease, clinically characterized by persistent, annular, erythematous lesions, revealing histopathologically perivascular infiltrates with abundant eosinophils. This report describes an unusual case of eosinophilic annular erythema in a 3-year-old female, requiring sustained doses of hydroxychloroquine to be adequately controlled. PMID:27579748

  7. Benign concentric annular macular dystrophy

    Directory of Open Access Journals (Sweden)

    Luísa Salles de Moura Mendonça

    2015-06-01

    Full Text Available The purpose of the authors is to show clinical findings of a patient with benign concentric annular macular dystrophy, which is an unusual condition, and part of the "bull’s eye" maculopathy differential diagnosis. An ophthalmologic examination with color perception, fluorescein angiography, and ocular electrophysiology was performed.

  8. Subcutaneous granuloma annulare: radiologic appearance

    International Nuclear Information System (INIS)

    Objective. Granuloma annulare is an uncommon benign inflammatory dermatosis characterized by the formation of dermal papules with a tendency to form rings. There are several clinically distinct forms. The subcutaneous form is the most frequently encountered by radiologists, with the lesion presenting as a superficial mass. There are only a few scattered reports of the imaging appearance of this entity in the literature. We report the radiologic appearance of five cases of subcutaneous granuloma annulare. Design and patients. The radiologic images of five patients (three male, two female) with subcutaneous granuloma annulare were retrospectively studied. Mean patient age was 6.4 years (range, 2-13 years). The lesions occurred in the lower leg (two), foot, forearm, and hand. MR images were available for all lesions, gadolinium-enhanced imaging in three cases, radiographs in four, and bone scintigraphy in one. Results. Radiographs showed unmineralized nodular masses localized to the subcutaneous adipose tissue. The size range, in greatest dimension on imaging studies, was 1-4 cm. MR images show a mass with relatively decreased signal intensity on all pulse sequences, with variable but generally relatively well defined margins. There was extensive diffuse enhancement following gadolinium administration. Conclusion. The radiologic appearance of subcutaneous granuloma annulare is characteristic, typically demonstrating a nodular soft-tissue mass involving the subcutaneous adipose tissue. MR images show a mass with relatively decreased signal intensity on all pulse sequences and variable but generally well defined margins. There is extensive diffuse enhancement following gadolinium administration. Radiographs show a soft-tissue mass or soft-tissue swelling without evidence of bone involvement or mineralization. This radiologic appearance in a young individual is highly suggestive of subcutaneous granuloma annulare. (orig.)

  9. Residence time distribution analysis of a 40 mm dia centrifugal extractor. Contributed Paper ED-02

    International Nuclear Information System (INIS)

    An annular centrifugal extractor utilizes annular gap between the rotating cylinder and the outer stationary vessel to mix two immiscible liquids in an intense shear field. For nuclear fuel reprocessing, large residence time of pulse column, mixer settler etc. will result in excessive solvent degradation. Annular centrifugal extractor (ACE) is the candid candidate as an extractor for FBR fuel reprocessing due to its short residence time and low holdup. Keeping the above points under consideration an ACE (40 mm) setup has been prepared on which non ideal analysis have been performed at varying rotational speeds (2000 rpm to 3600 rpm) at a fixed O/A ratio of 1 (100 ml per min each) and the number of tanks in series have been determined. It has been observed that above 2000 rpm the ACE behaves like a plug flow reactor. (author)

  10. Annular-Efficient Triangulations of 3-manifolds

    CERN Document Server

    Jaco, William

    2011-01-01

    A triangulation of a compact 3-manifold is annular-efficient if it is 0-efficient and the only normal, incompressible annuli are thin edge-linking. If a compact 3-manifold has an annular-efficient triangulation, then it is irreducible, boundary-irreducible, and an-annular. Conversely, it is shown that for a compact, irreducible, boundary-irreducible, and an-annular 3-manifold, any triangulation can be modified to an annular-efficient triangulation. It follows that for a manifold satisfying this hypothesis, there are only a finite number of boundary slopes for incompressible and boundary-incompressible surfaces of a bounded Euler characteristic.

  11. Rotating Biological Contactors (RBC's). Student Manual. Biological Treatment Process Control.

    Science.gov (United States)

    Zickefoose, Charles S.

    This student manual provides the textual material for a unit on rotating biological contactors (RBC's). Topic areas considered include: (1) flow patterns of water through RBC installations; (2) basic concepts (shaft and stage); (3) characteristics of biomass; (4) mechanical features (bearings, mechanical drive systems, and air drive systems); (5)…

  12. STRINGFELLOW LEACHATE TREATMENT WITH RBC (ROTATING BIOLOGICAL CONTACTOR)

    Science.gov (United States)

    A study was conducted with a rotating biological contactor (RBC) for treatment of leachate from the Stringfellow hazardous waste site in Riverside County, California. The leachate was transported from California to Cincinnati, where a pilot sized RBC was installed at the U.S. EPA...

  13. Carbon Dioxide Absorption in a Membrane Contactor with Color Change

    Science.gov (United States)

    Pantaleao, Ines; Portugal, Ana F.; Mendes, Adelio; Gabriel, Joaquim

    2010-01-01

    A pedagogical experiment is described to examine the physical absorption of gases, in this case carbon dioxide, in a hollow fiber membrane contactor (HFMC) where the absorption concentration profile can be followed by a color change. The HFMC is used to teach important concepts and can be used in interesting applications for students, such as…

  14. Centrifugal pump handbook

    CERN Document Server

    Pumps, Sulzer

    2010-01-01

    This long-awaited new edition is the complete reference for engineers and designers working on pump design and development or using centrifugal pumps in the field. This authoritative guide has been developed with access to the technical expertise of the leading centrifugal pump developer, Sulzer Pumps. In addition to providing the most comprehensive centrifugal pump theory and design reference with detailed material on cavitation, erosion, selection of materials, rotor vibration behavior and forces acting on pumps, the handbook also covers key pumping applications topics and operational

  15. DESIGN INFORMATION REPORT: CENTRIFUGES

    Science.gov (United States)

    In the 1960s, manufacturers began to design centrifuges specifically for wastewater sludge applications. In addition, sludge thickening and dewatering processes were improved with the introduction of polyelectrolytes for chemical sludge conditioning. The report contains a brief d...

  16. Psoriatic Arthritis with Annular Pustular Psoriasis.

    Science.gov (United States)

    Nagafuchi, Hiroko; Watanabe, Kyoko; Mikage, Hidenori; Ozaki, Shoichi

    2016-01-01

    We herein present the case of a 56-year-old woman who presented with symptoms of psoriatic arthritis (PsA) with erythema that progressed to annular pustular psoriasis. The patient had a 15-year history of polyarthritis. Annular pustular psoriasis is not typically observed in cases of arthritis. This is the first reported case of PsA with annular pustular psoriasis. PMID:26935375

  17. Electrolytically aided denitrification on a rotating biological contactor.

    Science.gov (United States)

    Rodziewicz, Joanna; Filipkowska, Urszula; Dziadkiewicz, Ewa

    2011-01-01

    The study was conducted at a bench scale on a rotating biological contactor under both conventional conditions (without the flow of electric current) and with the passage of an electric current having the following densities: 0.2 A m(-2), 0.8 A m(-)2 and 1.5 A m(-2). Stainless-steel discs covered with an immobilized biofilm served as a cathode, whereas an electrode made of stainless steel immersed in the wastewater of the flow tank of the contactor served as an anode. Experiments were carried out on municipal wastewater containing nitrogen in the organic and ammonium forms. The highest efficiency of nitrogen removal was observed with the passage of electric current at the density of 0.2 A m(-2). The efficiency of the denitrification process was over 64% and the nitrification efficiency was 93.4%.

  18. Systematic comparison of the use of annular and Zernike circle polynomials for annular wavefronts

    NARCIS (Netherlands)

    Mahajan, V.N.; Aftab, M.

    2010-01-01

    The theory of wavefront analysis of a noncircular wavefront is given and applied for a systematic comparison of the use of annular and Zernike circle polynomials for the analysis of an annular wavefront. It is shown that, unlike the annular coefficients, the circle coefficients generally change as t

  19. Treatment of Antibiotic Pharmaceutical Wastewater Using a Rotating Biological Contactor

    OpenAIRE

    Rongjun Su; Guangshan Zhang; Peng Wang; Shixiong Li; Ryan M. Ravenelle; JOHN C. CRITTENDEN

    2015-01-01

    Rotating biological contactors (RBC) are effective for treating wastewater, while they are rarely reported to be used for treating antibiotic pharmaceutical wastewater (APW). The current study investigates treatment of APW using an RBC. The effects of influent concentration, number of stages, and temperature on the remediation of APW were studied. The results indicated, even at low ambient temperature, 45% COD and 40% NH4+-N removal efficiencies. Moreover, the BOD5 removal efficiency was 85%....

  20. Membrane contactor assisted extraction/reaction process employing ionic liquids

    Science.gov (United States)

    Lin, Yupo J.; Snyder, Seth W.

    2012-02-07

    The present invention relates to a functionalized membrane contactor extraction/reaction system and method for extracting target species from multi-phase solutions utilizing ionic liquids. One preferred embodiment of the invented method and system relates to an extraction/reaction system wherein the ionic liquid extraction solutions act as both extraction solutions and reaction mediums, and allow simultaneous separation/reactions not possible with prior art technology.

  1. Confocal Annular Josephson Tunnel Junctions

    Science.gov (United States)

    Monaco, Roberto

    2016-04-01

    The physics of Josephson tunnel junctions drastically depends on their geometrical configurations and here we show that also tiny geometrical details play a determinant role. More specifically, we develop the theory of short and long annular Josephson tunnel junctions delimited by two confocal ellipses. The behavior of a circular annular Josephson tunnel junction is then seen to be simply a special case of the above result. For junctions having a normalized perimeter less than one, the threshold curves in the presence of an in-plane magnetic field of arbitrary orientations are derived and computed even in the case with trapped Josephson vortices. For longer junctions, a numerical analysis is carried out after the derivation of the appropriate motion equation for the Josephson phase. We found that the system is modeled by a modified and perturbed sine-Gordon equation with a space-dependent effective Josephson penetration length inversely proportional to the local junction width. Both the fluxon statics and dynamics are deeply affected by the non-uniform annulus width. Static zero-field multiple-fluxon solutions exist even in the presence of a large bias current. The tangential velocity of a traveling fluxon is not determined by the balance between the driving and drag forces due to the dissipative losses. Furthermore, the fluxon motion is characterized by a strong radial inward acceleration which causes electromagnetic radiation concentrated at the ellipse equatorial points.

  2. Confocal Annular Josephson Tunnel Junctions

    Science.gov (United States)

    Monaco, Roberto

    2016-09-01

    The physics of Josephson tunnel junctions drastically depends on their geometrical configurations and here we show that also tiny geometrical details play a determinant role. More specifically, we develop the theory of short and long annular Josephson tunnel junctions delimited by two confocal ellipses. The behavior of a circular annular Josephson tunnel junction is then seen to be simply a special case of the above result. For junctions having a normalized perimeter less than one, the threshold curves in the presence of an in-plane magnetic field of arbitrary orientations are derived and computed even in the case with trapped Josephson vortices. For longer junctions, a numerical analysis is carried out after the derivation of the appropriate motion equation for the Josephson phase. We found that the system is modeled by a modified and perturbed sine-Gordon equation with a space-dependent effective Josephson penetration length inversely proportional to the local junction width. Both the fluxon statics and dynamics are deeply affected by the non-uniform annulus width. Static zero-field multiple-fluxon solutions exist even in the presence of a large bias current. The tangential velocity of a traveling fluxon is not determined by the balance between the driving and drag forces due to the dissipative losses. Furthermore, the fluxon motion is characterized by a strong radial inward acceleration which causes electromagnetic radiation concentrated at the ellipse equatorial points.

  3. Bistability and hysteresis of annular impinging jets

    Science.gov (United States)

    Tisovsky, Tomas

    2016-06-01

    In present study, the bistability and hysteresis of annular impinging jets is investigated. Annular impinging jets are simulated using open source CFD code - OpenFOAM. Both flow field patterns of interest are obtained and hysteresis is found by means of dynamic mesh simulation. Effect of nozzle exit velocity on resulting hysteresis loop is also illustrated.

  4. Soliton bunching in annular Josephson junctions

    DEFF Research Database (Denmark)

    Vernik, I.V; Lazarides, Nickos; Sørensen, Mads Peter;

    1996-01-01

    By studying soliton (fluxon) motion in long annular Josephson junctions it is possible to avoid the influence of the boundaries and soliton-soliton collisions present in linear junctions. A new experimental design consisting of a niobium coil placed on top of an annular junction has been used...

  5. A Computer Model for Teaching the Dynamic Behavior of AC Contactors

    Science.gov (United States)

    Ruiz, J.-R. R.; Espinosa, A. G.; Romeral, L.

    2010-01-01

    Ac-powered contactors are extensively used in industry in applications such as automatic electrical devices, motor starters, and heaters. In this work, a practical session that allows students to model and simulate the dynamic behavior of ac-powered electromechanical contactors is presented. Simulation is carried out using a rigorous parametric…

  6. CO2 absorption at elevated pressures using a hollow fiber membrane contactor

    NARCIS (Netherlands)

    Dindore, V.Y.; Brilman, D.W.F.; Feron, P.H.M.; Versteeg, G.F.

    2004-01-01

    Recently, hollow fiber membrane gas–liquid contactor-based processes have gained an increasing attention. Compared to conventional processes, these processes have numerous advantages. The membrane contactors provide a very high interfacial area per unit volume, independent regulation of gas and liqu

  7. Optimum annular focusing by a phase plate

    CERN Document Server

    Arrizón, Victor; Aguirre-Olivas, Dilia; Mellado-Villaseñor, Gabriel

    2015-01-01

    Conventional light focusing, i. e. concentration of an extended optical field within a small area around a point, is a frequently used process in Optics. An important extension to conventional focusing is the generation of the annular focal field of an optical beam. We discuss a simple optical setup that achieves this kind of focusing employing a phase plate as unique optical component. We first establish the class of beams that being transmitted through the phase plate can be focused into an annular field with topological charge of arbitrary integer order q. Then, for each beam in this class we determine the plate transmittance that generates the focal field with the maximum possible peak intensity. In particular, we discuss and implement experimentally the optimum annular focusing of a Gaussian beam. The attributes of optimum annular focal fields, namely the high peak intensity, intensity gradient and narrow annular section, are advantageous for different applications of such structured fields.

  8. [Generalized granuloma annulare or diffuse dermal histiocytosis?].

    Science.gov (United States)

    Kretzschmar, L; Biel, K; Luger, T A; Goerdt, S

    1995-08-01

    Generalized granuloma annulare is a rare variant of granuloma annulare affecting the trunk and extremities with a multitude of lesions. In contrast to localized granuloma annulare, generalized granuloma annulare occurs in older patients, shows a stronger association with diabetes, and is characteristically chronic. Like our 55-year-old patient, most patients present with papules and annular plaques; less often, macular or non-annular lesions may be encountered. Histology often fails to show necrobiotic or necrotic connective tissue changes demarcated by a palisading granuloma. Instead, there are diffuse dermal, band-like or nodular aggregations of histiocytes intermingled with some multinucleated giant cells and a predominantly lymphocytic infiltrate in the periphery. Because of its special characteristics, it has been suggested that generalized granuloma annulare might constitute a separate disease entity and that it should be classed among the primary cutaneous histiocytoses as a diffuse dermal histiocytosis. Using immunohistochemistry to determine the macrophage phenotype of the lesional histiocytes, we have shown that generalized granuloma annulare is not a cutaneous histiocytosis. Neither MS-1 high-molecular-weight protein, a new specific marker for cutaneous non-Langerhans cell histiocytoses, nor CD1a, the well-known marker for Langerhans cells and Langerhans cell histiocytoses, is expressed by the lesional histiocytes of our patient. In contrast, the antigen expression pattern was diagnostic for non-infectious granulomas and was highly similar to that in localized granuloma annulare. In contrast to the successful treatment of localized granuloma annulare reported with intralesional interferon beta-1, systemic treatment with interferon alpha-2b (9 x 10(6) units three times a week) was ineffective.

  9. Geotechnical centrifuge under construction

    Science.gov (United States)

    Richman, Barbara T.

    Modifications are underway at the National Aeronautics and Space Administration (NASA) Ames Research Center in California to transform a centrifuge used in the Apollo space program to the largest geotechnical centrifuge in the free world. The centrifuge, to be finished in August and opened next January, following check out and tuning, will enable geoscientists to model stratigraphic features down to 275 m below the earth's surface. Scientists will be able to model processes that are coupled with body force loading, including earthquake response of earth structures and soil structure interaction; rubbled-bed behavior during in situ coal gasification or in oil shale in situ retorts; behavior of frozen soil; frost heave; behavior of offshore structures; wave-seabed interactions; explosive cratering; and blast-induced liquefaction.The centrifuge will have a load capacity of 900-g-tons (short); that is, it will be able to carry a net soil load of 3 short tons to a centripetal acceleration of 300 times the acceleration caused by gravity. Modified for a total cost of $2.4 million, the centrifuge will have an arm with a 7.6-m radius and a swinging platform or bucket at its end that will be able to carry a payload container measuring 2.1×2.1 m. An additional future input of $500,000 would enable the purchase of a larger bucket that could accommodate a load of up to 20 tons, according to Charles Babendreier, program director for geotechnical engineering at the National Science Foundation. Additional cooling for the motor would also be required. The centrifuge has the capability of accelerating the 20-ton load to 100 g.

  10. Perceived radial translation during centrifugation

    NARCIS (Netherlands)

    Bos, J.E.; Correia Grácio, B.J.

    2015-01-01

    BACKGROUND: Linear acceleration generally gives rise to translation perception. Centripetal acceleration during centrifugation, however, has never been reported giving rise to a radial, inward translation perception. OBJECTIVE: To study whether centrifugation can induce a radial translation percepti

  11. THE PERTURBATION SOLUTIONS OF THE FLOW IN A ROTATING CURVED ANNULAR PIPE

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In this paper, the flow in a rotating curved annular pipe isexamined by a perturbation method. A second order perturbation solution is presented. The characteristics of the secondary flow and the axial flow are studied in detail.The study indicates that the loops of the secondary flow are more complex than those in a curved annular pipe without rotation and its numbers depend on the ratio of the Coriolis force to centrifugal force F. As F ≈- 1 , the secondary flow has eight loops and its intensity reaches the minimum value, and the distribution of the axial flow is like that of the Poiseuille flow. The position of the maximum axial velocity is pushed to either outer bend or inner bend, which is also determined by F.

  12. Central centrifugal cicatricial alopecia

    OpenAIRE

    Collin Blattner; Dennis C Polley; Frank Ferritto; Elston, Dirk M

    2013-01-01

    Central centrifugal cicatricial alopecia is a common cause of progressive permanent apical alopecia. This unique form of alopecia includes entities previously know as “hot comb alopecia,” “follicular degeneration syndrome,” “pseudopelade” in African Americans and “central elliptical pseudopelade” in Caucasians. The etiology appears to be multifactorial and the condition occurs in all races.

  13. Centrifugal atomisation of alloys

    Energy Technology Data Exchange (ETDEWEB)

    Li Huiping [School of Mechanical and Materials Engineering, Univ. of Surrey, Guilford (United Kingdom); Dept. of Inorganic Materials, East China Univ. of Science and Technology, Shanghai, SH (China); Tsakiropoulos, P. [School of Mechanical and Materials Engineering, Univ. of Surrey, Guilford (United Kingdom); Johnson, T. [Tetronics Ltd., Faringdon, Oxfordshire (United Kingdom)

    2001-07-01

    Centrifugal atomisation using a rotating disk is described and compared to REP and PREP. Results of calculations of models describing the interaction of a melt with a rotating disk, the formation of thin film on the disk and the break up of the thin film and its atomisation at the edge of the disk are compared with experimental results. (orig.)

  14. Centrifugal analyzer development

    International Nuclear Information System (INIS)

    The development of the centrifuge fast analyzer (CFA) is reviewed. The development of a miniature CFA with computer data analysis is reported and applications for automated diagnostic chemical and hematological assays are discussed. A portable CFA system with microprocessor was adapted for field assays of air and water samples for environmental pollutants, including ammonia, nitrates, nitrites, phosphates, sulfates, and silica. 83 references

  15. Effect of Organic Loading on Rotating Biological Contactor Efficiency

    Directory of Open Access Journals (Sweden)

    Kossay K. Al-Ahmady

    2005-12-01

    Full Text Available Organic loading (weight per unit time per volume is useful for the design of rotating biological contactors (RBC and for comparison with the other processes such as activated sludge or oxidation ponds. The present study puts emphasis on the significance of this control or design parameter because it allows direct comparison of the RBC system's performance when operated under various circumstances and with different kinds of wastewater. The results of the paper proved that, the COD removal in rotating biological contactor systems is a function of the organic loading rate. However, each of the wastewater concentration and flow rate are also influence on the system efficiency but theirs impact can be combined by the effect of organic loading. The majority of COD removal (40-85 % of the total removal depending on the organic loading applied occurs in the first stages of the system. There is a strong correlation between the organic loading and the concentration of the suspended solids in the rotating biological contactor basin. At higher loadings higher concentrations noted. At a loading of about, (24 g/m2.d suspended solids were 225, 125, 35, and 25 mg/L in the first, second, third and, the fourth stage respectively. To achieve an effluent quality of (BOD < 25 mg/L, COD < 60 mg/L, the system must be operated on organic loadings of about (22 gBOD/m2.d and 65 gCOD/m2.d respectively. For nitrification process, the system must be designed to operate at organic loading of about (10 g/m2.d or less and, the reactor or basin volume should be designed to achieve a hydraulic loading of about (40 L/m2.d or less.

  16. Etizolam-induced superficial erythema annulare centrifugum.

    Science.gov (United States)

    Kuroda, K; Yabunami, H; Hisanaga, Y

    2002-01-01

    Erythema annulare centrifugum (EAC) is characterized by slowly enlarging annular erythematous lesions. Although the origin is not clear in most cases, EAC has been associated with infections, medications, and in rare cases, underlying malignancy. We describe a patient who developed annular erythematous lesions after etizolam administration. The eruptions were typical of the superficial form of EAC, both clinically and histopathologically. The lesions disappeared shortly after discontinuation of the medication. Patch testing with etizolam gave positive results. To our knowledge this is the first reported case of etizolam-induced superficial EAC. PMID:11952667

  17. Rotating biological contactors for wastewater treatment - A review

    OpenAIRE

    Hassard, Francis; Biddle, Jeremy R.; Cartmell, Elise; Jefferson, Bruce; Tyrrel, Sean F.; Stephenson, Tom

    2014-01-01

    Rotating biological contactors (RBCs) for wastewater treatment began in the 1970s. Removal of organic matter has been targeted within organic loading rates of up to 120 g m−2 d−1 with an optimum at around 15 g m−2 d−1 for combined BOD and ammonia removal. Full nitrification is achievable under appropriate process conditions with oxidation rates of up to 6 g m−2 d−1 reported for municipal wastewater. The RBC process has been adapted for denitrification with reported removal rates of up to 14 g...

  18. Divergent Field Annular Ion Engine Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed work investigates an approach that would allow an annular ion engine geometry to achieve ion beam currents approaching the Child-Langmuir limit. In...

  19. A clinical study of annular cyclitis

    Directory of Open Access Journals (Sweden)

    Marilita Michael Moschos

    2009-02-01

    Full Text Available Marilita Michael Moschos1, Yan Guex-Crosier2, Ioannis Margetis1, Leonidas Zografos21Department of Ophthalmology, University of Athens, Greece; 2Jules Gonin Eye Hospital, University of Lausanne, SwitzerlandPurpose: To investigate six cases of annular cyclitis.Methods: All patients with impairment of visual acuity underwent complete ophthalmologic examination, color fundus photography, laboratory tests and fluorescein angiography. Indocyanine green (ICG angiography and B-scan ultrasonography were also performed in three cases in order to diagnose the disease.Results: All patients presented a unilateral or bilateral granulomatous uveitis, associated with inflammatory annular cyclitis. They had a shallow anterior chamber, a mildly elevated intraocular pressure (under 25 mm Hg and an annular serous retinal detachment. A resolution was observed after specific therapy associated with systemic prednisolone therapy and antiglaucomatous drops.Conclusion: This is the first description of an observational study of six patients with inflammatory annular cyclitis.Keywords: cyclitis, uveitis, malignant glaucoma

  20. Performance characteristics of cross-flow membrane contactors for liquid desiccant systems

    International Nuclear Information System (INIS)

    Highlights: • Different types of flat plate membrane contactors developed to eliminate carryover in liquid desiccant systems. • Two-dimensional steady-state model developed to predict performance of contactors. • The simulated results are found to be in good agreement with experimental findings. • Performance of the contactors depends significantly on the membrane characteristics. • Parametric analysis carried out to select best operating ranges of design parameters. - Abstract: Membrane based indirect contact liquid desiccant dehumidification technology subsides the serious concern of liquid desiccant droplet carryover observed in conventional direct contact liquid desiccant systems. In the membrane contactor the air and liquid desiccant streams flow in alternate channels in cross-flow arrangement, separated by micro-porous semi-permeable hydrophobic membranes. Only water vapor can pass through the membranes but liquid desiccant cannot permeate. A two-dimensional steady-state mathematical model for semipermeable membrane based indirect contactors as dehumidifiers for liquid desiccant dehumidification applications has been developed. The model can predict the air and desiccant parameters inside the dehumidifier and the outlet parameters for a given input parameters. Five different membrane contactors have been fabricated and series of experiments have been conducted to validate the mathematical model. Aqueous solution of lithium chloride has been used as desiccant. The maximum deviations between experimental and predicted values are within ±10% for outlet specific humidity and outlet enthalpy of air, ±15% deviation in dehumidification effectiveness and ±20% deviation in enthalpy effectiveness. The distributions of major parameters viz. temperature, humidity, concentration, etc., within the contactor have been presented. Parametric analysis has been carried out to study the effects of membrane characteristics, contactor design, fluid flow rates, ambient

  1. Centrifugal steam-water separator for steam generators

    International Nuclear Information System (INIS)

    This invention concerns a centrifugal steam-water separator for steam generators, using natural circulation. The turbulence chamber includes a perforated venturi composed of a decreasing cone-shaped convergent duct and a cone-shaped divergent diffuser section increasing from the narrowest part to the turbulence chamber outlet. In this way, the jected liquid phase and any particles of solids it may contain can be discharged through the perforations into the annular space formed between the perforated venturi and the vessel to accumulate at the bottom of this annular space for subsequent removal. The advantages of the invention are that the diffuser of the perforated venturi is used as an additional separation path and with the recovery of pressure in mind, and that the water droplets ejected, as well as any particles contained in these droplets discharged or ejected outside the action area of the rotational flow into the annular space, can flow in a practically free way towards the bottom of the interior edge of the containment wall. Because of this, the pressure drop is reduced and the degree of separation improved. The steam-water separator of the invention is therefore particularly suitable for the high power steam generators of nuclear reactor facilities. For a given steam output, it is possible with the lay-out specified in this invention to reduce the required number of separation units

  2. Adaptive optics scanning ophthalmoscopy with annular pupils.

    Science.gov (United States)

    Sulai, Yusufu N; Dubra, Alfredo

    2012-07-01

    Annular apodization of the illumination and/or imaging pupils of an adaptive optics scanning light ophthalmoscope (AOSLO) for improving transverse resolution was evaluated using three different normalized inner radii (0.26, 0.39 and 0.52). In vivo imaging of the human photoreceptor mosaic at 0.5 and 10° from fixation indicates that the use of an annular illumination pupil and a circular imaging pupil provides the most benefit of all configurations when using a one Airy disk diameter pinhole, in agreement with the paraxial confocal microscopy theory. Annular illumination pupils with 0.26 and 0.39 normalized inner radii performed best in terms of the narrowing of the autocorrelation central lobe (between 7 and 12%), and the increase in manual and automated photoreceptor counts (8 to 20% more cones and 11 to 29% more rods). It was observed that the use of annular pupils with large inner radii can result in multi-modal cone photoreceptor intensity profiles. The effect of the annular masks on the average photoreceptor intensity is consistent with the Stiles-Crawford effect (SCE). This indicates that combinations of images of the same photoreceptors with different apodization configurations and/or annular masks can be used to distinguish cones from rods, even when the former have complex multi-modal intensity profiles. In addition to narrowing the point spread function transversally, the use of annular apodizing masks also elongates it axially, a fact that can be used for extending the depth of focus of techniques such as adaptive optics optical coherence tomography (AOOCT). Finally, the positive results from this work suggest that annular pupil apodization could be used in refractive or catadioptric adaptive optics ophthalmoscopes to mitigate undesired back-reflections.

  3. Centrifugal unbalance detection system

    Science.gov (United States)

    Cordaro, Joseph V.; Reeves, George; Mets, Michael

    2002-01-01

    A system consisting of an accelerometer sensor attached to a centrifuge enclosure for sensing vibrations and outputting a signal in the form of a sine wave with an amplitude and frequency that is passed through a pre-amp to convert it to a voltage signal, a low pass filter for removing extraneous noise, an A/D converter and a processor and algorithm for operating on the signal, whereby the algorithm interprets the amplitude and frequency associated with the signal and once an amplitude threshold has been exceeded the algorithm begins to count cycles during a predetermined time period and if a given number of complete cycles exceeds the frequency threshold during the predetermined time period, the system shuts down the centrifuge.

  4. Centrifugally decoupling touchdown bearings

    Science.gov (United States)

    Post, Richard F

    2014-06-24

    Centrifugally decoupling mechanical bearing systems provide thin tensioned metallic ribbons contained in a support structure. This assembly rotates around a stationary shaft being centered at low speeds by the action of the metal ribbons. Tension springs are connected on one end to the ribbons and on the other end to the support structure. The ribbons pass through slots in the inner ring of the support structure. The spring preloading thus insures contact (or near-contact) between the ribbons and the shaft at rotation speeds below the transition speed. Above this speed, however, the centrifugal force on the ribbons produces a tensile force on them that exceeds the spring tensile force so that the ribbons curve outward, effectively decoupling them from mechanical contact with the shaft. They still remain, however, in position to act as a touchdown bearing in case of abnormally high transverse accelerations.

  5. Performance in Centrifugal Compressors

    Directory of Open Access Journals (Sweden)

    K. Sato

    1999-01-01

    Full Text Available A 3-D unsteady thin-layer Navier-Stokes code has been used to calculate the flow through a centrifugal compressor stage. The validation of the code for steady flows in centrifugal compressors was conducted for the Krain’s impeller with a vaneless diffuser as a test case and the numerical results were compared with the experimental results. The predicted flow field and performance agreed well with the experimental data. An unsteady stage solution was then conducted with this impeller followed by a generic low-solidity vaned-diffuser to examine the unsteady effects on the impeller performance. The computational results showed a stabilising effect of the blade row interaction.

  6. Indicators for technological, environmental and economic sustainability of ozone contactors.

    Science.gov (United States)

    Zhang, Jie; Tejada-Martinez, Andres E; Lei, Hongxia; Zhang, Qiong

    2016-09-15

    Various studies have attempted to improve disinfection efficiency as a way to improve the sustainability of ozone disinfection which is a critical unit process for water treatment. Baffling factor, CT10, and log-inactivation are commonly used indicators for quantifying disinfection credits. However the applicability of these indicators and the relationship between these indicators have not been investigated in depth. This study simulated flow, tracer transport, and chemical species transport in a full-scale ozone contactor operated by the City of Tampa Water Department and six other modified designs using computational fluid dynamics (CFD). Through analysis of the simulation results, we found that baffling factor and CT10 are not optimal indicators of disinfection performance. We also found that the relationship between effluent CT obtained from CT transport simulation and baffling factor depends on the location of ozone release. In addition, we analyzed the environmental and economic impacts of ozone contactor designs and upgrades and developed a composite indicator to quantify the sustainability in technological, environmental and economic dimensions. PMID:27322565

  7. A new method for liposome preparation using a membrane contactor.

    Science.gov (United States)

    Jaafar-Maalej, Chiraz; Charcosset, Catherine; Fessi, Hatem

    2011-09-01

    In this article, we present a novel, scalable liposomal preparation technique suitable for the entrapment of pharmaceutical agents into liposomes. This new method is based on the ethanol-injection technique and uses a membrane contactor module, specifically designed for colloidal system preparation. In order to investigate the process, the influence of key parameters on liposome characteristics was studied. It has been established that vesicle-size distribution decreased with a decrease of the organic-phase pressure, an increase of the aqueous-phase flow rate, and a decrease of the phospholipid concentration. Additionally, special attention was paid on reproducibility and long-term stability of lipid vesicles, confirming the robustness of the membrane contactor-based technique. On the other hand, drug-loaded liposomes were prepared and filled with two hydrophobic drug models. High entrapment-efficiency values were successfully achieved for indomethacin (63%) and beclomethasone dipropionate (98%). Transmission electron microscopy images revealed nanometric quasispherical-shaped multilamellar vesicles (size ranging from 50 to 160 nm).

  8. Indicators for technological, environmental and economic sustainability of ozone contactors.

    Science.gov (United States)

    Zhang, Jie; Tejada-Martinez, Andres E; Lei, Hongxia; Zhang, Qiong

    2016-09-15

    Various studies have attempted to improve disinfection efficiency as a way to improve the sustainability of ozone disinfection which is a critical unit process for water treatment. Baffling factor, CT10, and log-inactivation are commonly used indicators for quantifying disinfection credits. However the applicability of these indicators and the relationship between these indicators have not been investigated in depth. This study simulated flow, tracer transport, and chemical species transport in a full-scale ozone contactor operated by the City of Tampa Water Department and six other modified designs using computational fluid dynamics (CFD). Through analysis of the simulation results, we found that baffling factor and CT10 are not optimal indicators of disinfection performance. We also found that the relationship between effluent CT obtained from CT transport simulation and baffling factor depends on the location of ozone release. In addition, we analyzed the environmental and economic impacts of ozone contactor designs and upgrades and developed a composite indicator to quantify the sustainability in technological, environmental and economic dimensions.

  9. Gas Centrifuges and Nuclear Proliferation

    Energy Technology Data Exchange (ETDEWEB)

    Albright, David

    2004-09-15

    Gas centrifuges have been an ideal enrichment method for a wide variety of countries. Many countries have built gas centrifuges to make enriched uranium for peaceful nuclear purposes. Other countries have secretly sought centrifuges to make highly enriched uranium for nuclear weapons. In more recent times, several countries have secretly sought or built gas centrifuges in regions of tension. The main countries that have been of interest in the last two decades have been Pakistan, Iraq, Iran, and North Korea. Currently, most attention is focused on Iran, Pakistan, and North Korea. These states did not have the indigenous abilities to make gas centrifuges, focusing instead on illicit and questionable foreign procurement. The presentation covered the following main sections: Spread of centrifuges through illicit procurement; Role of export controls in stopping proliferation; Increasing the transparency of gas centrifuge programs in non-nuclear weapon states; and, Verified dismantlement of gas centrifuge programs. Gas centrifuges are important providers of low enriched uranium for civil nuclear power reactors. They also pose special nuclear proliferation risks. We all have special responsibilities to prevent the spread of gas centrifuges into regions of tension and to mitigate the consequences of their spread into the Middle East, South Asia, and North Asia.

  10. Analysis of centrifugal convection in rotating pipes

    Science.gov (United States)

    Shtern, Vladimir; Zimin, Valery; Hussain, Fazle

    2001-08-01

    New exact solutions, obtained for centrifugal convection of a compressible fluid in pipes and annular pipes, explain axially elongated counterflow and energy separation—poorly understood phenomena occurring in vortex devices, e.g., hydrocyclones and Ranque tubes. Centrifugal acceleration (which can be up to 106 times gravity in practical vortex tubes), combined with an axial gradient of temperature (even small), induces an intense flow from the cold end to the hot end along the pipe wall and a backflow near the axis. To account for large density variations in vortex devices, we use the axial temperature gradient as a small parameter instead of the Boussinesq approximation. For weak pipe rotation, the swirl is of solid-body type and solutions are compact: vz/vza=1-4y2+3y4 and (T-Tw)/(Ta-Tw)=(1-y2)3; where y=r/rw, the subscripts w and a denote values of axial velocity vz, temperature T, and radial distance r, at the wall and on the axis. The axial gradient of pressure, being proportional to 3y2-1, has opposite directions near the wall, y=1, and near the axis, y=0; this explains the counterflow. With increasing pipe rotation, the flow starts to converge to the axis. This causes important new effects: (i) the density and swirl velocity maxima occur away from the wall (vortex core formation), (ii) the temperature near the axis becomes lower than near the wall (the Ranque effect), (iii) the axial gradient of temperature drops from the wall to the axis, and (iv) the total axial heat flux (Nu) reaches its maximum Numax≈4000 and then decreases as swirl increases. These features can be exploited for the development of a micro-heat-exchanger, e.g., for cooling computer chips.

  11. Tests of a Higgins contactor for the engineering-scale resin loading of uranium

    International Nuclear Information System (INIS)

    The loading of uranium on weak-acid ion exchange resin is a basic step in the production of fuel particles for high-temperature gas-cooled reactors (HTGRs). In the work reported here, an engineering-scale continuous resin loader (2-in.-ID Higgins contactor) was tested with existing engineering-scale process equipment. The Higgins contactor was first successfully used to convert Na+-form resin to the H+-form; then it was evaluated as a uranium loader. Results show that the 2-in.-ID Higgins contactor can easily load 25 kg of uranium per day, indicating that a 4-in.-ID contactor could load 100 kg/day. Process control was achieved by monitoring and controlling the density, pH, and inventory volume of the uranium feed solution. This control scheme is amenable to remote operation

  12. Simulation Study of AC Contactor Dynamic Contacts Contact Pressure Based on ADAMS

    Directory of Open Access Journals (Sweden)

    Gu Yungao

    2015-01-01

    Full Text Available A multi-body dynamics simulation model of CJ20-25 AC contactor was established with Pro/E(Pro/Engineerin this paper. A coupling simulation with machine, electric, magnetic on the contactor has been achieved in this model. Dynamic parameters which were called use the secondary development technology of ADAMS. The dynamic contact pressure signal of an AC contactor was obtained with ADAMS’s own simultaneous solution such as electromagnetic suction, kinematics and dynamics equations. The simulation results and actual measurement of contactor contact pressure signals are very similar. However, the complexity of the measured contacts vibration is greater than the simulation results because the actual working condition is more complex. This result provides a theoretical foundation to the dynamic contacts contact pressure test.

  13. OZONE CONTACTOR FLOW VISUALIZATION AND CHARACTERIZATION USING 3-DIMENSIONAL LASER INDUCED FLUORESCENCE

    Science.gov (United States)

    Hydrodynamics of ozone contactors have a crucial impact on efficient inactivation of pathogens such as Cryptosporidium as well as control of disinfection byproducts such as bromate. Improper mixing behaviors including short-circuiting, internal recirculation and presence...

  14. Applying Closing Phase-Angle Control Technique in Bounce Reduction of AC Permanent Magnet Contactor

    Directory of Open Access Journals (Sweden)

    Chieh-Tsung Chi

    2009-01-01

    Full Text Available A new low-cost electronic control circuit actuator is proposed for minimizing the bouncing times of an AC permanent magnet (PM contactor after two contacts closing. The proposed new actuator overcomes the bouncing problem of an uncontrollable restrictions imposed by previously conventional AC electromagnetic (EM contactor based on the minimization of kinetic energy prior to two contacts impact. By choosing the closing phase angle of coil voltage on purpose, the bouncing problems of the movable contact during the closing process are then overcome. The using life of contacts is then prolonged and their operating reliability is improved as well. In order to validate the feasibility and effectiveness of the proposed method here, several simulation and experimental procedures were performed on a prototype of AC PM contactor in the laboratory. Testing results actually showed that bouncing problem of contactor's contacts during the closing process was to be controlled by using the proposed technology.

  15. REVIEW OF CURRENT RBC (ROTATING BIOLOGICAL CONTACTOR) PERFORMANCE AND DESIGN PROCEDURES

    Science.gov (United States)

    The rapid emergence of rotating biological contactor (RBC) technology as an alternative secondary wastewater treatment process has increased the need to review their performance history to provide information to the design engineer. This study, to review and compare current desig...

  16. Centrifugal-reciprocating compressor

    Science.gov (United States)

    Higa, W. H. (Inventor)

    1984-01-01

    A centrifugal compressor is described which includes at least one pair of cylinders arranged in coaxial alignment and supported for angular displacement about a common axis of rotation normally disecting a common longitudinal axis of symmetry for the cylinders. The cylinders are characterized by ported closures located at the mutually remote ends thereof through which the cylinders are charged and discharged, and a pair of piston heads seated within the cylinders and supported for floating displacement in compressive strokes in response to unidirectional angular displacement imparted to the cylinders.

  17. Centrifugal bucket hoist

    OpenAIRE

    Kotačka, Petr

    2014-01-01

    This bachelor thesis deals with an engineering design of a centrifugal bucket elevator with transport height 6.5 metres and transport performance 40 000 kilograms per hour. The thesis focuses especially on a functional calculation of the elevator thanks to which a gear motor, band and bucket are chosen. This is followed by an analysis of a constructional solution with a strength check of a drive shaft and parallel keys as well as a calculation of a service life of bearings. Technical document...

  18. Flow measurements in a centrifugal diffusor test device

    Science.gov (United States)

    Vitting, T.

    1985-06-01

    This work sought to verify concepts used in the design of a large scale, low speed, radial cascade wind tunnel which was to be used to investigate flow phenomena in and the performance of vaned radial diffusors. A major contributor to centrifugal compressor efficiency is the performance of the vaned diffusor which closely follows the impeller of the compressor. The purpose of this diffusor is to efficiently convert most of the kinetic energy of the transonic flow entering the vane into pressure. The need for an experimental facility which could simulate adequately, at low cost and in a controlled way, the environment of the centrifugal compressor motivated the development of the Centrifugal Diffusor Test Device (CDTD). It was expected that the generation of a three dimensional flow would provide improved empirical data on annular cascade performance. This measurement program surveyed the axial and circumferential uniformity of the flow at the inlet of a transonic wedge-type blading mounted in the device. Evaluation of the results showed the flow uniformity to be unsatisfactory. Leakage and other small perturbations in the flow field in the swirl generator are believed to be amplified by the basic flow configuration of the device.

  19. Treatment of Antibiotic Pharmaceutical Wastewater Using a Rotating Biological Contactor

    Directory of Open Access Journals (Sweden)

    Rongjun Su

    2015-01-01

    Full Text Available Rotating biological contactors (RBC are effective for treating wastewater, while they are rarely reported to be used for treating antibiotic pharmaceutical wastewater (APW. The current study investigates treatment of APW using an RBC. The effects of influent concentration, number of stages, and temperature on the remediation of APW were studied. The results indicated, even at low ambient temperature, 45% COD and 40% NH4+-N removal efficiencies. Moreover, the BOD5 removal efficiency was 85%. Microscopic observations illustrated that there were various active microorganisms displayed in the biofilms and their distribution changed from stage to stage. Compared with activated sludge, the biofilms in this study have higher content of dry matter and are easier to dehydrate and settle. Compared with current commercial incineration processes or advanced oxidation processes, RBC can greatly reduce the treatment cost. This research shows RBC is effective for such an inherently biorecalcitrant wastewater even at low ambient temperature.

  20. DENITRIFICATION PROCESS ENHANCING IN FOUR-STAGES ROTATING BIOLOGICAL CONTACTOR

    Directory of Open Access Journals (Sweden)

    Artur Mielcarek

    2016-06-01

    Full Text Available The aim of the study was to determine the degree of an organic substrate consumption in the denitrification process involving a biofilm in four-stages laboratory scale rotating biological contactor (RBC. The discs submergence was 40% of their diameter. Acetic acid, used as external carbon source, was fed to the fourth stage of RBC. Consumption of substrate was observed for 2 and 24 hours. For a shorter period there was the removal of 37.9 ± 1.8 mg N·m-2, while using 499,9 ± 33.2 mg O2·m-2 of organic compounds. The prolongation of the experiment duration guaranteed higher efficiency of denitrification. The ratio of organic substrate used to the amount of nitrogen removed was 13: 1 and 21: 1 for 2 and 24 hours respectively.

  1. LOW-PRESSURE MEMBRANE CONTACTORS FOR CARBON DIOXIDE CAPTURE

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Richard; Kniep, Jay; Hao, Pingjiao; Chan, Chi Cheng; Nguyen, Vincent; Huang, Ivy; Amo, Karl; Freeman, Brice; Fulton, Don; Ly, Jennifer; Lipscomb, Glenn; Lou, Yuecun; Gogar, Ravikumar

    2014-09-30

    This final technical progress report describes work conducted by Membrane Technology and Research, Inc. (MTR) for the Department of Energy (DOE NETL) on development of low-pressure membrane contactors for carbon dioxide (CO2) capture from power plant flue gas (award number DE-FE0007553). The work was conducted from October 1, 2011 through September 30, 2014. The overall goal of this three-year project was to build and operate a prototype 500 m2 low-pressure sweep membrane module specifically designed to separate CO2 from coal-fired power plant flue gas. MTR was assisted in this project by a research group at the University of Toledo, which contributed to the computational fluid dynamics (CFD) analysis of module design and process simulation. This report details the work conducted to develop a new type of membrane contactor specifically designed for the high-gas-flow, low-pressure, countercurrent sweep operation required for affordable membrane-based CO2 capture at coal power plants. Work for this project included module development and testing, design and assembly of a large membrane module test unit at MTR, CFD comparative analysis of cross-flow, countercurrent, and novel partial-countercurrent sweep membrane module designs, CFD analysis of membrane spacers, design and fabrication of a 500 m2 membrane module skid for field tests, a detailed performance and cost analysis of the MTR CO2 capture process with low-pressure sweep modules, and a process design analysis of a membrane-hybrid separation process for CO2 removal from coal-fired flue gas. Key results for each major task are discussed in the report.

  2. Centrifugal shot blast system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    This report describes a demonstration of Concrete cleaning, Inc., modified centrifugal shot blast technology to remove the paint coating from concrete flooring. This demonstration is part of the Chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), office of Science and Technology (OST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East (ANL) CP-5 Research Reactor. The purpose of the LSDP is to demonstrate that using innovative and improved decontamination and decommissioning (D and D) technologies from various sources can result in significant benefits, such as decreased cost and increased health and safety, as compared with baseline D and D technologies. Potential markets exist for the innovative centrifugal shot blast system at the following sites: Fernald Environmental Management Project, Los Alamos, Nevada, Oak Ridge Y-12 and K-25, Paducah, Portsmouth Gaseous Diffusion site, and the Savannah River Site. This information is based on a revision to the OST Linkage Tables dated August 4, 1997.

  3. Centrifugal shot blast system

    International Nuclear Information System (INIS)

    This report describes a demonstration of Concrete cleaning, Inc., modified centrifugal shot blast technology to remove the paint coating from concrete flooring. This demonstration is part of the Chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), office of Science and Technology (OST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East (ANL) CP-5 Research Reactor. The purpose of the LSDP is to demonstrate that using innovative and improved decontamination and decommissioning (D and D) technologies from various sources can result in significant benefits, such as decreased cost and increased health and safety, as compared with baseline D and D technologies. Potential markets exist for the innovative centrifugal shot blast system at the following sites: Fernald Environmental Management Project, Los Alamos, Nevada, Oak Ridge Y-12 and K-25, Paducah, Portsmouth Gaseous Diffusion site, and the Savannah River Site. This information is based on a revision to the OST Linkage Tables dated August 4, 1997

  4. Annular bilayer magnetoelectric composites: theoretical analysis.

    Science.gov (United States)

    Guo, Mingsen; Dong, Shuxiang

    2010-01-01

    The laminated bilayer magnetoelectric (ME) composites consist of magnetostrictive and piezoelectric layers are known to have giant ME coefficient due to the high coupling efficiency in bending mode. In our previous report, the bar-shaped bilayer composite has been investigated by using a magnetoelectric-coupling equivalent circuit. Here, we propose an annular bilayer ME composite, which consists of magnetostrictive and piezoelectric rings. This composite has a much lower resonance frequency of bending mode compared with its radial mode. In addition, the annular bilayer ME composite is expected to respond to vortex magnetic field as well as unidirectional magnetic field. In this paper, we investigate the annular bilayer ME composite by using impedance-matrix method and predict the ME coefficients as a function of geometric parameters of the composites. PMID:20178914

  5. Stitching algorithm for annular subaperture interferometry

    Institute of Scientific and Technical Information of China (English)

    Xi Hou; Fan Wu; Li Yang; Shibin Wu; Qiang Chen

    2006-01-01

    @@ Annular subaperture interferometry (ASI) has been developed for low cost and flexible test of rotationally symmetric aspheric surfaces, in which accurately combining the subaperture measurement data corrupted by misalignments and noise into a complete surface figure is the key problem. By introducing the Zernike annular polynomials which are orthogonal over annulus, a method that eliminates the coupling problem in the earlier algorithm based on Zernike circle polynomials is proposed. Vector-matrix notation is used to simplify the description and calculations. The performance of this reduction method is evaluated by numerical simulation. The results prove this method with high precision and good anti-noise capability.

  6. Centrifugal microfluidics for biomedical applications.

    Science.gov (United States)

    Gorkin, Robert; Park, Jiwoon; Siegrist, Jonathan; Amasia, Mary; Lee, Beom Seok; Park, Jong-Myeon; Kim, Jintae; Kim, Hanshin; Madou, Marc; Cho, Yoon-Kyoung

    2010-07-21

    The centrifugal microfluidic platform has been a focus of academic and industrial research efforts for almost 40 years. Primarily targeting biomedical applications, a range of assays have been adapted on the system; however, the platform has found limited commercial success as a research or clinical tool. Nonetheless, new developments in centrifugal microfluidic technologies have the potential to establish wide-spread utilization of the platform. This paper presents an in-depth review of the centrifugal microfluidic platform, while highlighting recent progress in the field and outlining the potential for future applications. An overview of centrifugal microfluidic technologies is presented, including descriptions of advantages of the platform as a microfluidic handling system and the principles behind centrifugal fluidic manipulation. The paper also discusses a history of significant centrifugal microfluidic platform developments with an explanation of the evolution of the platform as it pertains to academia and industry. Lastly, we review the few centrifugal microfluidic-based sample-to-answer analysis systems shown to date and examine the challenges to be tackled before the centrifugal platform can be more broadly accepted as a new diagnostic platform. In particular, fully integrated, easy to operate, inexpensive and accurate microfluidic tools in the area of in vitro nucleic acid diagnostics are discussed.

  7. Optimal Thrust Vectoring for an Annular Aerospike Nozzle Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Recent success of an annular aerospike flight test by NASA Dryden has prompted keen interest in providing thrust vector capability to the annular aerospike nozzle...

  8. Unshrouded Centrifugal Turbopump Impeller

    Science.gov (United States)

    Prueger, George; Williams, Morgan; Chen, Wei; Paris, John; Stewart, Eric; Williams, Robert

    1999-01-01

    The ratio of rocket engine thrust to weight is a limiting constraint in placing more payload into orbit at a low cost. A key component of an engine's overall weight is the turbopump weight, Reducing the turbopump weight can result in significant engine weight reduction and hence, increased delivered payload. There are two main types of pumps: centrifugal and axial pumps. These types of pumps can be further sub-divided into those with shrouds and those without shrouds (unshrouded pumps). Centrifugal pumps can achieve the same pump discharge pressure as an axial pump and it requires fewer pump stages and lower pump weight than an axial pump. Also, with unshrouded centrifugal pumps (impeller), the number of stages and weight can be further reduced. However. there are several issues with regard to using an unshrouded impeller: 1) there is a pump performance penalty due to the front open face recirculation flow; 2) there is a potential pump axial thrust problem from the unbalanced front open face and the back shroud face; and, 3) since test data is very linu'ted for this configuration, there is uncertainty in the magnitude and phase of the rotordynamics forces due to the front impeller passage. The purpose of the paper is to discuss the design of an unshrouded impeller and to examine the design's hydrodynamic performance, axial thrust, and rotordynamics performance. The design methodology will also be discussed. This work will help provide some guidelines for unshrouded impeller design. In particular, the paper will discuss the design of three unshrouded impellers - one with 5 full and 5 partial blades (5+5). one with 6+6 blades and one with 8+8 blades. One of these designs will be selected for actual fabrication and flow test. Computational fluid dynamics (CFD) is used to help design and optimize the unshrouded impeller. The relative pump performance penalty is assessed by comparing the CFD results of the unshrouded impeller with the equivalent shrouded impeller for a

  9. Pre-Combustion Carbon Capture by a Nanoporous, Superhydrophobic Membrane Contactor Process

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Howard; Zhou, S James; Ding, Yong; Bikson, Ben

    2012-03-31

    This report summarizes progress made during Phase I and Phase II of the project: "Pre-Combustion Carbon Capture by a Nanoporous, Superhydrophobic Membrane Contactor Process," under contract DE-FE-0000646. The objective of this project is to develop a practical and cost effective technology for CO{sub 2} separation and capture for pre-combustion coal-based gasification plants using a membrane contactor/solvent absorption process. The goals of this technology development project are to separate and capture at least 90% of the CO{sub 2} from Integrated Gasification Combined Cycle (IGCC) power plants with less than 10% increase in the cost of energy services. Unlike conventional gas separation membranes, the membrane contactor is a novel gas separation process based on the gas/liquid membrane concept. The membrane contactor is an advanced mass transfer device that operates with liquid on one side of the membrane and gas on the other. The membrane contactor can operate with pressures that are almost the same on both sides of the membrane, whereas the gas separation membranes use the differential pressure across the membrane as driving force for separation. The driving force for separation for the membrane contactor process is the chemical potential difference of CO{sub 2} in the gas phase and in the absorption liquid. This process is thus easily tailored to suit the needs for pre-combustion separation and capture of CO{sub 2}. Gas Technology Institute (GTI) and PoroGen Corporation (PGC) have developed a novel hollow fiber membrane technology that is based on chemically and thermally resistant commercial engineered polymer poly(ether ether ketone) or PEEK. The PEEK membrane material used in the membrane contactor during this technology development program is a high temperature engineered plastic that is virtually non-destructible under the operating conditions encountered in typical gas absorption applications. It can withstand contact with most of the common treating

  10. [Galileo and centrifugal force].

    Science.gov (United States)

    Vilain, Christiane

    This work intends to focus on Galileo's study of what is now called "centrifugal force," within the framework of the Second Day of his Dialogo written in 1632, rather than on the previously published commentaries on the topic. Galileo proposes three geometrical demonstrations in order to prove that gravity will always overcome centrifugalforce, and that the potential rotation of the Earth, whatever its speed, cannot in any case project objects beyond it. Each of these demonstrations must consequently contain an error and it has seemed to us that the first one had not been understood up until now. Our analysis offers an opportunity to return to Galileo's geometrical representation of dynamical questions; actually, we get an insight into the sophistication of Galileo's practices more than into his mistakes. Our second point, concerning the historiography of the problem, shows an evolution from anachronic critics to more contextual considerations, in the course of the second half of the twentieth century.

  11. [Galileo and centrifugal force].

    Science.gov (United States)

    Vilain, Christiane

    This work intends to focus on Galileo's study of what is now called "centrifugal force," within the framework of the Second Day of his Dialogo written in 1632, rather than on the previously published commentaries on the topic. Galileo proposes three geometrical demonstrations in order to prove that gravity will always overcome centrifugalforce, and that the potential rotation of the Earth, whatever its speed, cannot in any case project objects beyond it. Each of these demonstrations must consequently contain an error and it has seemed to us that the first one had not been understood up until now. Our analysis offers an opportunity to return to Galileo's geometrical representation of dynamical questions; actually, we get an insight into the sophistication of Galileo's practices more than into his mistakes. Our second point, concerning the historiography of the problem, shows an evolution from anachronic critics to more contextual considerations, in the course of the second half of the twentieth century. PMID:25029818

  12. Azimuthally forced flames in an annular combustor

    Science.gov (United States)

    Worth, Nicholas; Dawson, James; Mastorakos, Epaminondas

    2015-11-01

    Thermoacoustic instabilities are more likely to occur in lean burn combustion systems, making their adoption both difficult and costly. At present, our knowledge of such phenomena is insufficient to produce an inherently stable combustor by design, and therefore an improved understanding of these instabilities has become the focus of a significant research effort. Recent experimental and numerical studies have demonstrated that the symmetry of annular chambers permit a range of self-excited azimuthal modes to be generated in annular geometry, which can make the study of isolated modes difficult. While acoustic forcing is common in single flame experiments, no equivalent for forced azimuthal modes in an annular chamber have been demonstrated. The present investigation focuses on the novel application of acoustic forcing to a laboratory scale annular combustor, in order to generate azimuthal standing wave modes at a prescribed frequency and amplitude. The results focus on the ability of the method to isolate the mode of oscillation using experimental pressure and high speed OH* measurements. The successful excitation of azimuthal modes demonstrated represents an important step towards improving our fundamental understanding of this phenomena in practically relevant geometry.

  13. Annular beam with segmented phase gradients

    Directory of Open Access Journals (Sweden)

    Shubo Cheng

    2016-08-01

    Full Text Available An annular beam with a single uniform-intensity ring and multiple segments of phase gradients is proposed in this paper. Different from the conventional superposed vortices, such as the modulated optical vortices and the collinear superposition of multiple orbital angular momentum modes, the designed annular beam has a doughnut intensity distribution whose radius is independent of the phase distribution of the beam in the imaging plane. The phase distribution along the circumference of the doughnut beam can be segmented with different phase gradients. Similar to a vortex beam, the annular beam can also exert torques and rotate a trapped particle owing to the orbital angular momentum of the beam. As the beam possesses different phase gradients, the rotation velocity of the trapped particle can be varied along the circumference. The simulation and experimental results show that an annular beam with three segments of different phase gradients can rotate particles with controlled velocities. The beam has potential applications in optical trapping and optical information processing.

  14. Fluxon Dynamics in Elliptic Annular Josephson Junctions

    DEFF Research Database (Denmark)

    Monaco, Roberto; Mygind, Jesper

    2016-01-01

    We analyze the dynamics of a magnetic flux quantum (current vortex) trapped in a current-biased long planar elliptic annular Josephson tunnel junction. The system is modeled by a perturbed sine-Gordon equation that determines the spatial and temporal behavior of the phase difference across the tu...

  15. Membrane contactor assisted water extraction system for separating hydrogen peroxide from a working solution, and method thereof

    Science.gov (United States)

    Snyder, Seth W.; Lin, Yupo J.; Hestekin' Jamie A.; Henry, Michael P.; Pujado, Peter; Oroskar, Anil; Kulprathipanja, Santi; Randhava, Sarabjit

    2010-09-21

    The present invention relates to a membrane contactor assisted extraction system and method for extracting a single phase species from multi-phase working solutions. More specifically one preferred embodiment of the invention relates to a method and system for membrane contactor assisted water (MCAWE) extraction of hydrogen peroxide (H.sub.2O.sub.2) from a working solution.

  16. Evaluating hydraulic and disinfection efficiencies of a full-scale ozone contactor using a RANS-based modeling framework.

    Science.gov (United States)

    Zhang, Jie; Tejada-Martínez, Andrés E; Zhang, Qiong; Lei, Hongxia

    2014-04-01

    The capability of predicting hydraulic and disinfection efficiencies of ozone disinfection contactors is essential for evaluating existing contactors and improving future designs. Previous attempts based on ideal and non-ideal models for the hydraulics and simplified mechanisms for chemical reaction modeling have resulted in low accuracy and are restricted to contactors with simple geometries. This manuscript develops a modeling framework for the ozonation process by combining computational fluid dynamics (CFD) with a kinetics-based reaction modeling for the first time. This computational framework has been applied to the full-scale ozone contactor operated by the City of Tampa Water Department. Flow fields, residence time distribution, ozone concentration distribution, and concentration-contact time (CT) distribution within the contactor have been predicted via the computational framework. The predictions of ozone and bromate concentrations at sample points agree well with physical experimental data measured in the contactor. The predicted CT values at the contactor outlet demonstrate that the disinfection performance of the ozone contactor operated by the City of Tampa Water Department is sufficient to meet regulation requirements. The impact of seasonal flow rate change on disinfection performance is found to be significant and deserves attention during the management and operation of a water treatment plant.

  17. Microwave assisted centrifuge and related methods

    Science.gov (United States)

    Meikrantz, David H [Idaho Falls, ID

    2010-08-17

    Centrifuge samples may be exposed to microwave energy to heat the samples during centrifugation and to promote separation of the different components or constituents of the samples using a centrifuge device configured for generating microwave energy and directing the microwave energy at a sample located in the centrifuge.

  18. Uranium enrichment by gas centrifuge

    International Nuclear Information System (INIS)

    After recalling the physical principles and the techniques of centrifuge enrichment the report describes the centrifuge enrichment programmes of the various countries concerned and compares this technology with other enrichment technologies like gaseous diffusion, laser, aerodynamic devices and chemical processes. The centrifuge enrichment process is said to be able to replace with advantage the existing enrichment facilities in the short and medium term. Future prospects of the process are also described, like recycled uranium enrichment and economic improvements; research and development needs to achieve the economic prospects are also indicated. Finally the report takes note of the positive aspect of centrifuge enrichment as far as safeguards and nuclear safety are concerned. 27 figs, 113 refs

  19. Mass Transfer And Hydraulic Testing Of The V-05 And V-10 Contactors With The Next Generation Solvent

    Energy Technology Data Exchange (ETDEWEB)

    Herman, D. T.; Duignan, M. R.; Williams, M. R.; Peters, T. B.; Poirier, M. R.; Fondeur, F. F.

    2013-07-31

    The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent. To support this integration of NGS into the MCU facilities, Savannah River Remediation (SRR) requested that Savannah River National Laboratory (SRNL) perform testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing differs from prior testing by utilizing a blend of BOBCalixC6 based solvent and the NGS with the full (0.05 M) concentration of the MaxCalix as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. Stage efficiency and mass distribution ratios were determined by measuring Cs concentration in the aqueous and organic phases during single contactor testing. The nominal cesium distribution ratio, D(Cs) measured for extraction ranged from 37-60. The data showed greater than 96% stage efficiency for extraction. No significant differences were noted for operations at 4, 8 or 12 gpm aqueous salt simulant feed flow rates. The first scrub test (contact with weak caustic solution) yielded average scrub D(Cs) values of 3.3 to 5.2 and the second scrub test produced an average value of 1.8 to 2.3. For stripping behavior, the “first stage” D Cs) values ranged from 0.04 to 0.08. The efficiency of the low flow (0.27 gpm aqueous) was calculated to be 82.7%. The Spreadsheet

  20. Mass Transfer And Hydraulic Testing Of The V-05 And V-10 Contactors With The Next Generation Solvent

    International Nuclear Information System (INIS)

    The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent. To support this integration of NGS into the MCU facilities, Savannah River Remediation (SRR) requested that Savannah River National Laboratory (SRNL) perform testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing differs from prior testing by utilizing a blend of BOBCalixC6 based solvent and the NGS with the full (0.05 M) concentration of the MaxCalix as well as a new suppressor, tris(3,7 dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. Stage efficiency and mass distribution ratios were determined by measuring Cs concentration in the aqueous and organic phases during single contactor testing. The nominal cesium distribution ratio, D(Cs) measured for extraction ranged from 37-60. The data showed greater than 96% stage efficiency for extraction. No significant differences were noted for operations at 4, 8 or 12 gpm aqueous salt simulant feed flow rates. The first scrub test (contact with weak caustic solution) yielded average scrub D(Cs) values of 3.3 to 5.2 and the second scrub test produced an average value of 1.8 to 2.3. For stripping behavior, the ''first stage'' D Cs) values ranged from 0.04 to 0.08. The efficiency of the low flow (0.27 gpm aqueous) was calculated to be 82.7%. The Spreadsheet

  1. Gas centrifugal separator

    International Nuclear Information System (INIS)

    Object: To enhance separating performance by jointly using separating action of impulse wave without increasing peripheral speed of a gas centrifugal separator and lengthening a cylindrical portion thereof. Structure: A mixed gas is introduced into a rotating cylinder from a mixed gas pipe and is separated into gas rich in light component and gas decreased in light component, these gases being taken outside the rotating cylinder through a product opening and a fixed waste pipe, respectively. A fixed product recycling pipe is disposed between an upper end plate and an upper buffer plate of the rotating cylinder the recycling pipe having an opening formed at the leading end so as to oppose to the rotating mixed gas, and the gas introduced from the opening is re-introduced into the central portion of the rotating cylinder for recirculation. A waste pipe is disposed between a lower end plate and a lower buffer plate of the rotating cylinder, and the gas not introduced into the opening of the waste pipe is circulated within the rotating cylinder. (Kamimura, M.)

  2. Preliminary Study of Greywater Treatment through Rotating Biological Contactor

    Directory of Open Access Journals (Sweden)

    Ashfaq Ahmed Pathan

    2011-07-01

    Full Text Available The characteristics of the greywater vary from country to country and it depends upon the cultural and social behavior of the respective country. There was a considerable need to characterize and recycle the greywater. In this regard greywater was separated from the black water and analyzed for various physiochemical parameters. Among various greywater recycling treatment technologies, RBC (Rotating Biological Contactor is more effective treatment technique in reducing COD (Chemical Oxygen Demand and organic matters from the greywater. But this technology was not applied and tested in Pakistan. There was extensive need to investigate the RBC technology for greywater recycling at small scale before applying at mass scale. To treat the greywater, a single-stage RBC simulator was designed and developed at laboratory scale. An electric motor equipped with gear box to control the rotations of the disks was mounted on the tank. The simulator was run at the rate of 1.7 rpm. The disc area of the RBC was immersed about 40% in the greywater. Water samples were collected at each HRT (Hydraulic Retention Time and analyzed for the parameters such as pH, conductivity, TDS (Total Dissolved Solids, salinity, BOD5 (Biochemical Oxygen Demand, COD and suspended solids by using standard methods. The results are encouraging with percentage removal of BOD5 and COD being 53 and 60% respectively.

  3. Effect of Sedimentation on Treated Greywater Through Rotating Biological Contactor

    Directory of Open Access Journals (Sweden)

    Ashfaque Ahmed Pathan

    2016-06-01

    Full Text Available The aim of this paper was to study the effect of sedimentation on effluent of a pilot scale Rotating Biological Contactor (RBC. The treated greywater was given three hours sedimentation period and samples were analyzed to observe the effect of sedimentations under variousflow rates. Greywater was separated from the black water and collected in the collection tank and then it was pumped to an overhead tank. This tank supplied a regulated continuous flow of greywater into the RBC chamber at the required flow rate ranging between 0.28 to 1.89 l/min. A pilot scale RBC simulator was developed and placed outside a hall of residence at National Center of Excellence in Analytical Chemistry, Sindh University, Jamshoro. The simulator was operated at the rotational speed of discs of 1.7 rpm. The disks were uneven and textured so as to encourage growth of bacteria on them. These discs were immersed about 40 percent in the greywater.The simulator produced effluent of significant quality and was found efficient in removal of BOD5, COD and TSS as 85%, 68% and 95% respectively.

  4. A turbulent bed contactor: energetic efficiency for particle collection

    Directory of Open Access Journals (Sweden)

    M. L. Gimenes

    2007-03-01

    Full Text Available Particle collection experiments were conducted in a fluidizing irrigated bed to evaluate the performance of mobile packings: 38 x 50 mm plain oblate spheroids 38 mm ID plain spheres and alternative perforated spheres with a 38 mm ID and 10% and 25% free areas were used as fluidizing media in a 0.264 m diameter and 1.20 m high turbulent bed contactor (TBC. Particle collection experiments were carried out above the minimum fluidization velocity, using as particulate test powder polysized alumina (size 1.5 to 5.5 mm. Experimental results demonstrated that the perforated spheres performed better in collecting particles than the other packings tested. The efficiency of particle collection was analysed based on energy consumption in the TBC, using the energetic efficiency concept. It was verified that not much more energy was consumed per unit of gas flow in fluidized beds of perforated packings than in those of conventional plain sphere packings, since the perforated spheres were more energetically efficient for particle collection than plain spheres and oblate spheroid packings.

  5. Modified rotating biological contactor for removal of dichloromethane vapours.

    Science.gov (United States)

    Ravi, R; Philip, Ligy; Swaminathan, T

    2015-01-01

    Bioreactors are used for the treatment of waste gas and odour that has gained much acceptance in the recent years to treat volatile organic compounds (VOCs). The different types of bioreactors (biofilter, biotrickling filter and bioscrubber) have been used for waste gas treatment. Each of these reactors has some advantages and some limitations. Though biodegradation is the main process for the removal of the pollutants, the mechanisms of removal and the microbial communities may differ among these bioreactors. Consequently, their performance or removal efficiency may also be different. Clogging of reactor and pressure drop are the main problems. In this study attempts are made to use the principle of rotating biological contactor (RBC) used for wastewater treatment for the removal of VOC. To overcome the above problem the RBC is modified which is suitable for the treatment of VOC (dichloromethane, DCM). DCM is harmful to human health and hazardous to the atmospheric environment. Modified RBC had no clogging problems and no pressure drop. So, it can handle the pollutant load for a longer period of time. A maximum elimination capacity of 25.7 g/m3 h has been achieved in this study for the DCM inlet load of 58 g/m3 h. The average biofilm thickness is 1 mm. The transient behaviour of the modified RBC treating DCM was investigated. The modified RBC is able to handle shutdown, restart and shock loading operations.

  6. Life Cycle Tests on a Hollow Cathode Based Plasma Contactor

    Science.gov (United States)

    Vaughn, Jason A.; Schneider, Todd A.; Munafo, Paul (Technical Monitor)

    2001-01-01

    The propulsive Small Expendable Deployer System (ProSEDS) mission is designed to provide an on-orbit demonstration of the electrodynamic propulsion capabilities of tethers in space. The ProSEDS experiment will be a secondary payload on a Delta II unmanned expendable booster with a mission duration of 12 days. A 5-km conductive tether is attached to the Delta II second stage and collects current from the low Earth orbit (LEO) plasma, and a Hollow Cathode Plasma Contactor (HCPC) emits the collected electrons from the Delta II, completing the electrical circuit to the ambient plasma. The HCPC for the ProSEDS mission have made it necessary to turn off the HCPC once a minute throughout the entire mission. Because of the unusual operating requirements by the ProSEDS mission, an engineering development unit of the HCPC was built to demonstrate the HCPC design would start reliably for the life of the ProSEDS mission. During the life test the engineering unit cycled for over 10,000 on/off cycles without missing a single start, and during that same test the HCPC unit demonstrated the capability to emit 0 to 5 A electron emission current. The performance of the HCPC unit during this life test will be discussed.

  7. Apparatus for supporting contactors used in extracting nuclear materials from liquids

    Science.gov (United States)

    Leonard, Ralph A.; Frank, Robert C.

    1991-01-01

    Apparatus is provided for supporting one or more contactor stages used to remove radioactive materials from aqueous solutions. The contactor stages include a housing having an internal rotor, a motor secured to the top of the housing for rotating the rotor, and a drain in the bottom of the housing. The support apparatus includes two or more vertical members each secured to a ground support that is horizontal and perpendicular to the frame member, and a horizontally disposed frame member. The frame member may be any suitable shape, but is preferably a rectangular tube having substantially flat, spaced top and bottom surfaces separated by substantially vertical side surfaces. The top and bottom surfaces each have an opening through which the contactor housing is secured so that the motor is above the frame and the drain is below the frame during use.

  8. Application of PTFE membrane for ammonia removal in a membrane contactor.

    Science.gov (United States)

    Ahn, Y T; Hwang, Y H; Shin, H S

    2011-01-01

    The feasibility of a membrane contactor system for ammonia removal was studied. The mass transfer coefficient was used to quantitatively compare the effect of various operation conditions on ammonia removal efficiency. Effective removal of ammonia was possible with a Polytetrafluoroethylene (PTFE) membrane contactor system at all tested conditions. Among the various operation parameters, contact time and solution pH showed significant effect on the ammonia removal mechanism. The overall ammonia removal rate was not affected by influent suspended solution concentration unlike other pressure driven membrane filtration processes. Also the osmotic distillation phenomena which deteriorate the mass transfer efficiency can be minimized by preheating of influent wastewater. A membrane contactor system can be a possible alternative to treat high strength nitrogen wastewater by optimizing operation conditions such as stripping solution flow rate, influent wastewater temperature, and influent pH.

  9. Non newtonian annular alloy solidification in mould

    Energy Technology Data Exchange (ETDEWEB)

    Moraga, Nelson O.; Garrido, Carlos P. [Universidad de La Serena, Departamento de Ingenieria Mecanica, La Serena (Chile); Castillo, Ernesto F. [Universidad de Santiago de Chile, Departamento de Ingenieria Mecanica, Santiago (Chile)

    2012-08-15

    The annular solidification of an aluminium-silicon alloy in a graphite mould with a geometry consisting of horizontal concentric cylinders is studied numerically. The analysis incorporates the behavior of non-Newtonian, pseudoplastic (n=0.2), Newtonian (n=1), and dilatant (n=1.5) fluids. The fluid mechanics and heat transfer coupled with a transient model of convection diffusion are solved using the finite volume method and the SIMPLE algorithm. Solidification is described in terms of a liquid fraction of a phase change that varies linearly with temperature. The final results make it possible to infer that the fluid dynamics and heat transfer of solidification in an annular geometry are affected by the non-Newtonian nature of the fluid, speeding up the process when the fluid is pseudoplastic. (orig.)

  10. Annular pancreas associated with duodenal carcinoma

    Institute of Scientific and Technical Information of China (English)

    Enrico; Bronnimann; Silke; Potthast; Tatjana; Vlajnic; Daniel; Oertli; Oleg; Heizmann

    2010-01-01

    Annular pancreas (AP) is a rare congenital anomaly. Coexisting malignancy has been reported only in a few cases. We report what is, to the best of our knowledge, the first case in the English literature of duodenal adenocarcinoma in a patient with AP. In a 55-year old woman with duodenal outlet stenosis magnetic resonance cholangiopancreatography showed an aberrant pancreatic duct encircling the duodenum. Duodenojejunostomy was performed. Eight weeks later she presented with painless jaundice. Duodenopancre...

  11. Performance of annular high frequency thermoacoustic engines

    Science.gov (United States)

    Rodriguez, Ivan A.

    This thesis presents studies of the behavior of miniature annular thermoacoustic prime movers and the imaging of the complex sound fields using PIV inside the small acoustic wave guides when driven by a temperature gradient. Thermoacoustic engines operating in the standing wave mode are limited in their acoustic efficiency by a high degree of irreversibility that is inherent in how they work. Better performance can be achieved by using traveling waves in the thermoacoustic devices. This has led to the development of an annular high frequency thermoacoustic prime mover consisting of a regenerator, which is a random stack in-between a hot and cold heat exchanger, inside an annular waveguide. Miniature devices were developed and studied with operating frequencies in the range of 2-4 kHz. This corresponds to an average ring circumference of 11 cm for the 3 kHz device, the resonator bore being 6 mm. A similar device of 11 mm bore, length of 18 cm was also investigated; its resonant frequency was 2 kHz. Sound intensities as high as 166.8 dB were generated with limited heat input. Sound power was extracted from the annular structure by an impedance-matching side arm. The nature of the acoustic wave generated by heat was investigated using a high speed PIV instrument. Although the acoustic device appears symmetric, its performance is characterized by a broken symmetry and by perturbations that exist in its structure. Effects of these are observed in the PIV imaging; images show axial and radial components. Moreover, PIV studies show effects of streaming and instabilities which affect the devices' acoustic efficiency. The acoustic efficiency is high, being of 40% of Carnot. This type of device shows much promise as a high efficiency energy converter; it can be reduced in size for microcircuit applications.

  12. Annular Alopecia Areata: Report of Two Cases

    OpenAIRE

    Bansal, Manish; Manchanda, Kajal; Pandey, SS

    2013-01-01

    Alopecia areata (AA) is an auto-immune disorder characterized by the appearance of non-scarring bald patches affecting the hair bearing areas of the body. Scalp is the most common site of involvement. AA can affect any age group. The usual pattern of the hair loss is oval or round. We hereby, report two cases of annular and circinate pattern of AA due to its unusual morphology.

  13. Vibration analysis of annular-like plates

    Science.gov (United States)

    Cheng, L.; Li, Y. Y.; Yam, L. H.

    2003-05-01

    The existence of eccentricity of the central hole for an annular plate results in a significant change in the natural frequencies and mode shapes of the structure. In this paper, the vibration analysis of annular-like plates is presented based on numerical and experimental approaches. Using the finite element analysis code Nastran, the effects of the eccentricity, hole size and boundary condition on vibration modes are investigated systematically through both global and local analyses. The results show that analyses for perfect symmetric conditions can still roughly predict the mode shapes of "recessive" modes of the plate with a slightly eccentric hole. They will, however, lead to erroneous results for "dominant" modes. In addition, the residual displacement mode shape is verified as an effective parameter for identifying damage occurring in plate-like structures. Experimental modal analysis on a clamped-free annular-like plate is performed, and the results obtained reveal good agreement with those obtained by numerical analysis. This study provides guidance on modal analysis, vibration measurement and damage detection of plate-like structures.

  14. Modeling and Hardware-in-the-loop Simulations of Contactor Dynamics : Mechanics, Electromagnetics and Software

    OpenAIRE

    Tjerngren, Jon

    2014-01-01

    This master thesis’s subject is to model an ABB contactor’s dynamics and to develop a hardware-in-the-loop simulation environment. The hardware-in-the-loop method utilizes computer models that are simulated in a real-time simulator. The real-time simulator is connected to hardware components. A contactor is an electrically controlled mechanical switching device and it is used in circuits where large currents can occur. In this thesis, the contactor is divided into three separate subsystems an...

  15. Hyperbolically Shaped Centrifugal Compressor

    Institute of Scientific and Technical Information of China (English)

    Romuald Puzyrewski; Pawel Flaszy(n)ski

    2003-01-01

    Starting from the classical centrifugal compressor, cone shaped in meridional cross section, two modifications are considered on the basis of results from 2D and 3D flow models. The first modification is the change of the meridional cross section to hyperbolically shaped channel. The second modification, proposed on the basis of 2D axisymmetric solution, concerns the shape of blading. On the strength of this solution the blades are formed as 3D shaped blades, coinciding with the recent tendency in 3D designs. Two aims were considered for the change of meridional compressor shape. The first was to remove the separation zone which appears as the flow tums from axial to radial direction. The second aim is to uniformize the flow at exit of impeller. These two goals were considered within the frame of 2D axisymmetric model. Replacing the cone shaped compressor by a hyperbolically shaped one, the separation at the corner was removed. The disc and shroud shape of the compressor was chosen in the way which satisfies the condition of most uniform flow at the compressor exit. The uniformity of exit flow from the rotor can be considered as the factor which influences the performance of the diffuser following the rotor. In the 2D model a family of stream surfaces of S1 type is given in order to find S2 surfaces which may be identified with the midblade surfaces of compressor blading. A computation of 3D type has been performed in order to establish the relations between 2D and 3D models in the calculation of flow parameters. In the presented example the 2D model appears as the inverse model which leads to 3D shape of blading whereas the 3D model has been used for the direct solution. In the presented example the confrontation of two models, 2D and 3D, leads to a better understanding of the application of these models to the design procedure.

  16. Centrifugation. A theoretical study of oxygen enrichment by centrifugation

    Energy Technology Data Exchange (ETDEWEB)

    Kierkegaard, P.; Raetz, E.

    1998-12-01

    In the present paper we first investigate what happens if we fill a cylinder with air, close it and rotate it. The results show that no matter which peripheral speed is used, it is not possible by means of the radial separation effect alone, to enrich the oxygen concentration from the previous 21% to more then 23.3%, which is of no practical value. In case of a too low enrichment in one centrifuge, the wanted material from this centrifuge can be used as an input for a second centrifuge and so on, in this way forming a cascade of centrifuges. Oxygen will be enriched in each step, until the desired concentration is reached. Cascading was the technology in the very beginning by enrichment plants for uraniumhexaflouride, used for atomic weapons and nuclear power plants. In this study we try to avoid cascading by aiming for higher separation factors. Therefore, we next investigate the possibilities of using a countercurrent centrifuge where in principle the enriched gas is subjected to several centrifugation in the same centrifuge. The calculations show, that in this way it is possible to produce nearly a 100% pure oxygen (polluted with some heavier molecules like argon) in one machine. Our third step was to calculate the amount of oxygen produced per hour. Using a countercurrent centrifuge of the Zippe type, 100 cm high and 20 cm in diameter, it is or will be possible in the near future to produce 17 g enriched air per hour enriched to 50% oxygen. That corresponds to processing 1 m{sup 3} atmospherical air in the period of approximately 24 hours. This is not very impressive. Our fourth step was to estimate the amount of power used for producing this amount of oxygen. A rough, but complicated, estimate shows that the power consumption at the production level will be about the double of the consumption used today. The overall conclusion is, that centrifugation as a production method for oxygen (or nitrogen) will not be competitive with the currently used method in the

  17. THE INTERACTION OF LIQUID DROPS WITH A ROTATING GAS STREAM WITHIN A RAPIDLY REVOLVING ANNULAR ENCLOSURE

    Directory of Open Access Journals (Sweden)

    A. AROUSSI

    2006-12-01

    Full Text Available The flow phenomena occurring around a rotating shaft are extremely complex and are a common feature in turbomachinery such as the bearing chambers of aero engines. As the liquid jet impinges onto the shaft, circumferential streams of lubricating liquid droplets centrifuge away from the rotor surface and impinge onto the inner circumference of the stationary case. A further break-up of drops occurred whilst rotating around the shaft before impacting on to the casing surface. Non-intrusive laser techniques have been employed to aid the visualisation processes and the analysis of the flow phenomena occurring within the rotating annular enclosure. Results reveal that, the liquid flow conditions and the shaft rotation regimes, along with the aerodynamic movement of the air circulating around the shaft influence the dynamics of the droplets and consequently the lubrication processes within the bearing chambers.

  18. Pressure loss due to the tip clearance of impellar blades in centrifugal and axial blowers

    Science.gov (United States)

    Senoo, Y.

    Equations to evaluate pressure loss based on the tip clearance of impeller blades (pressure loss induced by the leakage flow through the clearance, and pressure loss for supporting fluid against the pressure gradient in the thin annular clearance space between the shroud and the impeller) are derived. The predicted pressure losses are compared with experimental data for two types of centrifugal impellers. The equations are simplified for axial impellers as a special case, and the predicted efficiency-drop is compared with the experimental data for seven cases. Good agreement is demonstrated.

  19. Effect of Annular Slit Geometry on Characteristics of Spiral Jet

    Institute of Scientific and Technical Information of China (English)

    Shigeru Matsuo; Kwon-Hee Lee; Shinsuke Oda; Toshiaki Setoguchi; Heuy-Dong Kim

    2003-01-01

    A spiral flow using an annular slit connected to a conical cylinder does not need special device to generate a tangential velocity component of the flow and differs from swirling flows. Pressurized fluid is supplied to an annular chamber and injected into the convergent nozzle through the annular slit. The annular jet develops into the spiral flow. In the present study, a spiral jet discharged out of nozzle exit was obtained by using a convergent nozzle and an annular slit set in nozzle inlet, and the effect of annular slit geometry on characteristics of the spiral jet was investigated by using a Laser Doppler Velocimeter (LDV) experimentally. Furthermore, velocity distributions of the spiral jet were compared with those of a normal jet.

  20. FOULING CHARACTERIZATION OF MEMBRANE CONTACTORS USED FOR THE RECOVERY AND CONCENTRATION OF AMMONIA FROM UNDIGESTED PIG SLURRY

    DEFF Research Database (Denmark)

    Zarebska, Agata; Norddahl, Birgir; Christensen, Knud Villy

    2012-01-01

    The main obstacle impeding implementation of membrane contactors for the recovery and concentration of ammonia from swine manure is the phenomena of membrane fouling. Fouling is defined as the accumulation of suspended or dissolved substances on the membrane surface and/or within its pores. Due...... a week of running the contactor without cleaning. This indicates that fouling could be a severe problem. The intensity of fouling can be reduced by feed pretreatment and by optimizing the operating conditions of the membrane contactor. This will also facilitate removal of ammonia....

  1. 新型交流接触器的应用%Application of New Type of AC Contactor

    Institute of Scientific and Technical Information of China (English)

    刘冬英; 李克芹

    2009-01-01

    简要介绍了TJ40(CJ45)系列新型交流接触器,详细阐述了两种派生产品的用途、结构、特点和应用,即机械联锁可逆交流接触器和切换电容器交流接触器.%The TJ40(CJ45)series new of AC contactors were introduced briefly.The use,structure,trait and application of the two derived contactor products,viz.mechanical interlock reversible AC contactor and smtching capacitor AC eontactor,were expounded.

  2. Granuloma annulare localized to the shaft of the penis

    DEFF Research Database (Denmark)

    Trap, R; Wiebe, B

    1993-01-01

    A case of granuloma annulare localized to the shaft of the penis is reported. The differential diagnoses are discussed. Penile granuloma annulare is a rare disorder and it is concluded that biopsies of penile lesions are recommended to verify the correct diagnosis.......A case of granuloma annulare localized to the shaft of the penis is reported. The differential diagnoses are discussed. Penile granuloma annulare is a rare disorder and it is concluded that biopsies of penile lesions are recommended to verify the correct diagnosis....

  3. Treatment of anaerobically pre-treated domestic sewage by a rotating biological contactor

    NARCIS (Netherlands)

    Tawfik, A.; Klapwijk, A.; el-Gohary, F.; Lettinga, G.

    2002-01-01

    The performance of a rotating biological contactor (RBC) for the post-treatment of the effluent of an up-flow anaerobic sludge blanket (UASB) was the subject of this study. Different hydraulic and organic loading rates have been investigated. The removal efficiencies of CODtotal, CODsuspended, CODco

  4. Surface-Roughness-Based Virtual Textiles: Evaluation Using a Multi-Contactor Display.

    Science.gov (United States)

    Philpott, Matthew; Summers, Ian R

    2015-01-01

    Virtual textiles, generated in response to exploratory movements, are presented to the fingertip via a 24-contactor vibrotactile array. Software models are based on surface-roughness profiles from real textiles. Results suggest that distinguishable "textile-like" surfaces are produced, but these lack the necessary accuracy for reliable matching to real textiles.

  5. Validation of a simple method for predicting the disinfection performance in a flow-through contactor.

    Science.gov (United States)

    Pfeiffer, Valentin; Barbeau, Benoit

    2014-02-01

    Despite its shortcomings, the T10 method introduced by the United States Environmental Protection Agency (USEPA) in 1989 is currently the method most frequently used in North America to calculate disinfection performance. Other methods (e.g., the Integrated Disinfection Design Framework, IDDF) have been advanced as replacements, and more recently, the USEPA suggested the Extended T10 and Extended CSTR (Continuous Stirred-Tank Reactor) methods to improve the inactivation calculations within ozone contactors. To develop a method that fully considers the hydraulic behavior of the contactor, two models (Plug Flow with Dispersion and N-CSTR) were successfully fitted with five tracer tests results derived from four Water Treatment Plants and a pilot-scale contactor. A new method based on the N-CSTR model was defined as the Partially Segregated (Pseg) method. The predictions from all the methods mentioned were compared under conditions of poor and good hydraulic performance, low and high disinfectant decay, and different levels of inactivation. These methods were also compared with experimental results from a chlorine pilot-scale contactor used for Escherichia coli inactivation. The T10 and Extended T10 methods led to large over- and under-estimations. The Segregated Flow Analysis (used in the IDDF) also considerably overestimated the inactivation under high disinfectant decay. Only the Extended CSTR and Pseg methods produced realistic and conservative predictions in all cases. Finally, a simple implementation procedure of the Pseg method was suggested for calculation of disinfection performance.

  6. Using 3D LIF to Investigate and Improve Performance of a Multichamber Ozone Contactor

    Science.gov (United States)

    Three-dimensional laser-induced fluorescence (3DLIF) was applied to visualize and quantitatively analyze hydrodynamics and mixing in a multi-chamber ozone contactor, the most widely used design for water disinfection. The results suggested that the mixing was characterized by ext...

  7. Modelling of cross-flow membrane contactors : Physical mass transfer processes

    NARCIS (Netherlands)

    Dindore, V. Y.; Brilman, D. W. F.; Versteeg, G. F.

    2005-01-01

    Traditionally, hollow fiber membrane contactors used for gas-liquid contacting were designed in a shell and tube configuration with shell-side fluid flowing parallel to the fiber-side fluid, either in co-current or counter-current pattern. The primary limitations of these so-called 'parallel flow' c

  8. Membrane–solvent selection for CO2 removal using membrane gas–liquid contactors

    NARCIS (Netherlands)

    Dindore, V.Y.; Brilman, D.W.F.; Geuzebroek, F.H.; Versteeg, G.F.

    2004-01-01

    Membrane gas–liquid contactors can provide very high interfacial area per unit volume, independent regulation of gas and liquid flows and are insensitive to module orientation, which make them very attractive in comparison with conventional equipments for offshore application. However, the membrane

  9. Axial liquid mixing in a gas-liquid Multi-Stage Agitated Contactor (MAC)

    NARCIS (Netherlands)

    Breman, B.B; Beenackers, A.A C M; Bouma, M.J; VanderWerf, M.H.

    1996-01-01

    Data on interstage liquid mixing are reported for a gas-liquid Multi-stage Agitated Contactor (MAC). A dynamic method using heat as a tracer was applied for water, n-octane and monoethylene glycol as liquids both with and without the presence of a dispersed gas phase (air). In all cases, the axial m

  10. Extraction of uranium from in-situ leach solutions using the NIMCIX ion exchange contactor

    International Nuclear Information System (INIS)

    The NIMCIX ion exchange column is a multi-stage fluidized bed contactor to permit a counter-current flow of solution and resin in order to maximize extraction efficiency. Batch or continuous elution methods with fully automated or manual control systems may be selected for different process solution conditions. 8 refs

  11. Biofilm growth of Chlorella sorokiniana in a rotating biological contactor based photobioreactor

    NARCIS (Netherlands)

    Blanken, W.M.; Janssen, M.G.J.; Cuaresma, M.; Libor, Z.; Bhaiji, T.; Wijffels, R.H.

    2014-01-01

    Microalgae biofilms could be used as a production platform for microalgae biomass. In this study, a photobioreactor design based on a rotating biological contactor (RBC) was used as a production platform for microalgae biomass cultivated in biofilm. In the photobioreactor, referred to as Algadisk, m

  12. Amine-based solvents regeneration in gas-liquid membrane contactor based on asymmetric PVTMS

    NARCIS (Netherlands)

    Volkov, A.V.; Tsarkov, S.E.; Goetheer, E.L.V.; Volkov, V.V.

    2015-01-01

    Asymmetric flat-sheet membranes made of poly(vinyltrimethylsilane) (PVTMS) were studied for the regeneration of amine-based absorption solvents in a membrane gas-liquid contactor at 100°C. It was shown that PVTMS membrane possesses good mechanical and chemical stability in contact with 4 M monoethan

  13. Centrifugation and the Manhattan Project

    Science.gov (United States)

    Reed, Cameron

    2009-05-01

    A study of U. S. Army Manhattan Engineer District documents reveals that consideration of centrifugation as a means of uranium enrichment during World War II was considerably more extensive than is commonly appreciated. By the time the centrifuge project was abandoned in early 1944 a full-scale prototype unit had been fabricated and tested at near-production speeds, enrichments of close to theoretically-expected levels had been demonstrated with pilot-plant units, and plans for production plants had been developed. This paper will review the history of this little-known aspect of the Project and examine the circumstances of how it came to be discontinued.

  14. Wave turbulence in annular wave tank

    Science.gov (United States)

    Onorato, Miguel; Stramignoni, Ettore

    2014-05-01

    We perform experiments in an annular wind wave tank at the Dipartimento di Fisica, Universita' di Torino. The external diameter of the tank is 5 meters while the internal one is 1 meter. The tank is equipped by two air fans which can lead to a wind of maximum 5 m/s. The present set up is capable of studying the generation of waves and the development of wind wave spectra for large duration. We have performed different tests including different wind speeds. For large wind speed we observe the formation of spectra consistent with Kolmogorv-Zakharov predictions.

  15. Finite stretching of an annular plate.

    Science.gov (United States)

    Biricikoglu, V.; Kalnins, A.

    1971-01-01

    The problem of the finite stretching of an annular plate which is bonded to a rigid inclusion at its inner edge is considered. The material is assumed to be isotropic and incompressible with a Mooney-type constitutive law. It is shown that the inclusion of the effect of the transverse normal strain leads to a rapid variation in thickness which is confined to a narrow edge zone. The explicit solutions to the boundary layer equations, which govern the behavior of the plate near the edges, are presented.

  16. Thread-annular flow in vertical pipes

    Science.gov (United States)

    Frei, Ch.; Lüscher, P.; Wintermantel, E.

    2000-05-01

    Thread injection is a promising method for different minimally invasive medical applications. This paper documents an experimental study dealing with an axially moving thread in annular pipe flow. Mass flow and axial force on the thread are measured for a 0.46 mm diameter thread in pipes with diameters between 0.55 and 1.35 mm. The experiments with thread velocities of up to 1.5 ms[minus sign]1 confirm the findings of theoretical studies that for clinical requirements the radius ratio between thread and pipe is crucial for the adjustments of mass ow and force on the thread.

  17. Deep variant of Erythema Annulare Centrifugum

    OpenAIRE

    Ahu Yorulmaz; Ferda Artuz; Devrim Tuba Unal

    2014-01-01

    A 29-year-old woman came to our outpatient clinic with a several-month history of itchy red lesions over her trunk. There was no family history and past history of any other diseases or medication. Dermatological examination revealed annular and oval-shaped plaques up to several cm’s in size, one of which was polycyclic in configuration, on back of the patient (Fig. 1). It was also noticed that lesions had erythematous indurated bordes with paler central areas (Fig. 1).

  18. Deep variant of Erythema Annulare Centrifugum

    Directory of Open Access Journals (Sweden)

    Ahu Yorulmaz

    2014-10-01

    Full Text Available A 29-year-old woman came to our outpatient clinic with a several-month history of itchy red lesions over her trunk. There was no family history and past history of any other diseases or medication. Dermatological examination revealed annular and oval-shaped plaques up to several cm’s in size, one of which was polycyclic in configuration, on back of the patient (Fig. 1. It was also noticed that lesions had erythematous indurated bordes with paler central areas (Fig. 1.

  19. Annular lupus vulgaris mimicking tinea cruris.

    Science.gov (United States)

    Heo, Young Soo; Shin, Won Woong; Kim, Yong Ju; Song, Hae Jun; Oh, Chil Hwan

    2010-05-01

    Cutaneous tuberculosis is an infrequent form of extrapulmonary tuberculosis. It is often clinically and histopathologically confused with various cutaneous disorders. A 36-year-old man attended our clinic with slowly progressive, asymptomatic, annular skin lesions on both the thighs and buttocks for 10 years. He consulted with many physicians and was improperly treated with an oral antifungal agent for several months under the diagnosis of tinea cruris, but no resolution of his condition was observed. A diagnosis of lupus vulgaris was made based on the histopathologic examination and the polymerase chain reaction assay. Anti-tuberculosis therapy was administered and the lesions started to regress.

  20. Mass transport in annular spherical system

    Science.gov (United States)

    Bauer, Helmut F.

    The mass transport between two concentric spheres with inlet and outlet at the poles was determined for ideal liquid flow (plug flow) and laminar flow for constant concentration at the spherical walls and constant concentration at the inlet. Velocity distribution and local concentration profiles were determined analytically for various widths of the annular spherical conduit and various diffusive flow parameters. It is found that with the increase of this parameter, the decay becomes quite rapid and that the same effect occurs for increasing diameter ratio of the spheres. This configuration may possibly be used as a basic element of an artificial kidney.

  1. Mass Transfer And Hydraulic Testing Of The V-05 And V-10 Contactors With The Next Generation Solvent

    Energy Technology Data Exchange (ETDEWEB)

    Herman, D. T.; Duignan, M. R.; Williams, M. R.; Peters, T. B.; Poirier, M. R.; Fondeur, F. F.

    2013-07-31

    The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent. To support this integration of NGS into the MCU facilities, Savannah River Remediation (SRR) requested that Savannah River National Laboratory (SRNL) perform testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing differs from prior testing by utilizing a blend of BOBCalixC6 based solvent and the NGS with the full (0.05 M) concentration of the MaxCalix as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. Stage efficiency and mass distribution ratios were determined by measuring Cs concentration in the aqueous and organic phases during single contactor testing. The nominal cesium distribution ratio, D(Cs) measured for extraction ranged from 37-60. The data showed greater than 96% stage efficiency for extraction. No significant differences were noted for operations at 4, 8 or 12 gpm aqueous salt simulant feed flow rates. The first scrub test (contact with weak caustic solution) yielded average scrub D(Cs) values of 3.3 to 5.2 and the second scrub test produced an average value of 1.8 to 2.3. For stripping behavior, the “first stage” D Cs) values ranged from 0.04 to 0.08. The efficiency of the low flow (0.27 gpm aqueous) was calculated to be 82.7%. The Spreadsheet

  2. Empirical Design Considerations for Industrial Centrifugal Compressors

    OpenAIRE

    Cheng Xu; Amano, Ryoichi S.

    2012-01-01

    Computational Fluid Dynamics (CFD) has been extensively used in centrifugal compressor design. CFD provides further optimisation opportunities for the compressor design rather than designing the centrifugal compressor. The experience-based design process still plays an important role for new compressor developments. The wide variety of design subjects represents a very complex design world for centrifugal compressor designers. Therefore, some basic information for centrifugal design is still ...

  3. Performance of a Centrifugal Slurry Pump

    OpenAIRE

    Hawas Yahya Bajawi; Basharat Salim; Ziyadh Suhibani

    2014-01-01

    The aim of this study was to experimentally investigate the effect of speed, concentration and size of slurry on the performance of a centrifugal pump. For this purpose a facility was built where the performance of a centrifugal slurry pump was examined using aggregate slurry. Three sizes of slurry with three concentrations and at three impeller speeds were used for the performance investigations of a centrifugal slurry pump. As a reference performance the performance of centrifugal slurry pu...

  4. Continuous-Flow Centrifugal Separator

    Science.gov (United States)

    Waldron, Robert D.

    1988-01-01

    Apparatus combines principles of centrifugal and cyclone separators to control movement of solid or liquid particles suspended in flowing gas. Spinning disk contains radial channels, width varys as function of distance from center. Gas flows from outer ring around disk toward center. Particles in gas collected at periphery, center or both.

  5. Centrifugal pumps for rocket engines

    Science.gov (United States)

    Campbell, W. E.; Farquhar, J.

    1974-01-01

    The use of centrifugal pumps for rocket engines is described in terms of general requirements of operational and planned systems. Hydrodynamic and mechanical design considerations and techniques and test procedures are summarized. Some of the pump development experiences, in terms of both problems and solutions, are highlighted.

  6. Laser and gas centrifuge enrichment

    Energy Technology Data Exchange (ETDEWEB)

    Heinonen, Olli [Senior Fellow, Belfer Center for Science and International Affairs, Harvard Kennedy School, Cambridge, Massachusetts (United States)

    2014-05-09

    Principles of uranium isotope enrichment using various laser and gas centrifuge techniques are briefly discussed. Examples on production of high enriched uranium are given. Concerns regarding the possibility of using low end technologies to produce weapons grade uranium are explained. Based on current assessments commercial enrichment services are able to cover the global needs of enriched uranium in the foreseeable future.

  7. Laser and gas centrifuge enrichment

    Science.gov (United States)

    Heinonen, Olli

    2014-05-01

    Principles of uranium isotope enrichment using various laser and gas centrifuge techniques are briefly discussed. Examples on production of high enriched uranium are given. Concerns regarding the possibility of using low end technologies to produce weapons grade uranium are explained. Based on current assessments commercial enrichment services are able to cover the global needs of enriched uranium in the foreseeable future.

  8. Annular and semicircular lipoatrophies. Report of three cases and review of the literature.

    Science.gov (United States)

    Rongioletti, F; Rebora, A

    1989-03-01

    Two cases of semicircular lipoatrophy and one of annular lipoatrophy are presented. The reasons why semicircular lipoatrophy, annular lipoatrophy, and annular atrophy of the ankles seem to be different clinical entities are discussed.

  9. Detonation diffraction from an annular channel

    Science.gov (United States)

    Meredith, James; Ng, Hoi Dick; Lee, John H. S.

    2010-12-01

    In this study, gaseous detonation diffraction from an annular channel was investigated with a streak camera and the critical pressure for transmission of the detonation wave was obtained. The annular channel was used to approximate an infinite slot resulting in cylindrically expanding detonation waves. Two mixtures, stoichiometric acetylene-oxygen and stoichiometric acetylene-oxygen with 70% Ar dilution, were tested in a 4.3 and 14.3 mm channel width ( W). The undiluted and diluted mixtures were found to have values of the critical channel width over the cell size around 3 and 12 respectively. Comparing these results to values of the critical diameter ( d c ), in which a spherical detonation occurs, a value of critical d c / W c near 2 is observed for the highly diluted mixture. This value corresponds to the geometrical factor of the curvature term between a spherical and cylindrical diverging wave. Hence, the result is in support of Lee's proposed mechanism [Lee in Dynamics of Exothermicity, pp. 321, Gordon and Breach, Amsterdam, 1996] for failure due to diffraction based on curvature in stable mixtures such as those highly argon diluted with very regular detonation cellular patterns.

  10. Annular beam shaping and optical trepanning

    Science.gov (United States)

    Zeng, Danyong

    Percussion drilling and trepanning are two laser drilling methods. Percussion drilling is accomplished by focusing the laser beam to approximately the required diameter of the hole, exposing the material to one or a series of laser pulses at the same spot to melt and vaporize the material. Drilling by trepanning involves cutting a hole by rotating a laser beam with an optical element or an x-y galvo-scanner. Optical trepanning is a new laser drilling method using an annular beam. The annular beams allow numerous irradiance profiles to supply laser energy to the workpiece and thus provide more flexibility in affecting the hole quality than a traditional circular laser beam. Heating depth is important for drilling application. Since there are no good ways to measure the temperature inside substrate during the drilling process, an analytical model for optical trepanning has been developed by considering an axisymmetric, transient heat conduction equation, and the evolutions of the melting temperature isotherm, which is referred to as the melt boundary in this study, are calculated to investigate the influences of the laser pulse shapes and intensity profiles on the hole geometry. This mathematical model provides a means of understanding the thermal effect of laser irradiation with different annular beam shapes. To take account of conduction in the solid, vaporization and convection due to the melt flow caused by an assist gas, an analytical two-dimensional model is developed for optical trepanning. The influences of pulse duration, laser pulse length, pulse repetition rate, intensity profiles and beam radius are investigated to examine their effects on the recast layer thickness, hole depth and taper. The ray tracing technique of geometrical optics is employed to design the necessary optics to transform a Gaussian laser beam into an annular beam of different intensity profiles. Such profiles include half Gaussian with maximum intensities at the inner and outer

  11. Limited Diffraction Maps for Pulsed Wave Annular Arrays

    DEFF Research Database (Denmark)

    Fox, Paul D.

    2002-01-01

    A procedure is provided for decomposing the linear field of flat pulsed wave annular arrays into an equivalent set of known limited diffraction Bessel beams. Each Bessel beam propagates with known characteristics, enabling good insight into the propagation of annular fields to be obtained...

  12. Obtention of an empirical equation for annular channels

    International Nuclear Information System (INIS)

    Using a trial circuit, the experimental heat transfer coefficient is determined, in forced convection at one phase only within an annular channel in which water flows ascendantly and for this reason an empirical equation is determined. This work tries to contribute to the understanding of the forced convection phenomena in non tubular geometries like the annular channels. (Author)

  13. 75 FR 23582 - Annular Casing Pressure Management for Offshore Wells

    Science.gov (United States)

    2010-05-04

    ... Recommended Practice (RP) 90. As explained in API RP 90, Section 3, Annular Casing Pressure Management Program... Institute's Recommended Practice for managing annular casing pressure. New regulations are needed because... Continental Shelf lessees to follow best industry practices for wells with sustained casing pressure....

  14. Effect of annular secondary conductor in a linear electromagnetic stirrer

    Indian Academy of Sciences (India)

    R Madhavan; V Ramanarayanan

    2008-10-01

    This paper presents the variation of average axial force density in the annular secondary conductor of a linear electromagnetic stirrer. Different geometries of secondaries are considered for numerical and experimental validation namely, 1. hollow annular ring, 2. annular ring with a solid cylinder and 3. solid cylinder. Experimental and numerical simulations are performed for a 2-pole in house built 15 kW linear electromagnetic stirrer (EMS). It is observed for a supply current of 200 A at 30 Hz the force densities in the hollow annular ring is 67% higher than the equivalent solid cylinder. The same values are 33% for annular ring with a solid cylinder. Force density variation with supply frequency and current are also reported. Numerical simulations using finite element model are validated with experimental results.

  15. Nuclear fuel cycle studies

    International Nuclear Information System (INIS)

    For the metal-matrix encapsulation of radioactive waste, brittle-fracture, leach-rate, and migration studies are being conducted. For fuel reprocessing, annular and centrifugal contactors are being tested and modeled. For the LWBR proof-of-breeding project, the full-scale shear and the prototype dissolver were procured and tested. 5 figures

  16. Centrifugal separator devices, systems and related methods

    Science.gov (United States)

    Meikrantz, David H.; Law, Jack D.; Garn, Troy G.; Todd, Terry A.; Macaluso, Lawrence L.

    2012-03-20

    Centrifugal separator devices, systems and related methods are described. More particularly, fluid transfer connections for a centrifugal separator system having support assemblies with a movable member coupled to a connection tube and coupled to a fixed member, such that the movable member is constrained to movement along a fixed path relative to the fixed member are described. Also, centrifugal separator systems including such fluid transfer connections are described. Additionally, methods of installing, removing and/or replacing centrifugal separators from centrifugal separator systems are described.

  17. Design of a centrifugal blood pump: Heart Turcica Centrifugal.

    Science.gov (United States)

    Demir, Onur; Biyikli, Emre; Lazoglu, Ismail; Kucukaksu, Suha

    2011-07-01

    A prototype of a new implantable centrifugal blood pump system named Heart Turcica Centrifugal (HTC) was developed as a left ventricular assist device (LVAD) for the treatment of end-stage cardiac failure. In the development of HTC, effects of blade height and volute tongue profiles on the hydraulic and hemolytic performances of the pump were investigated. As a result, the prototype was manufactured using the best blade height and volute tongue profiles. Performance of the prototype model was experimentally evaluated in a closed-loop flow system using water as the medium. The hydraulic performance requirement of an LVAD (5 L/min flow rate against a pressure difference of 100 mm Hg) was attained at 2800 rpm rotational speed.

  18. Simulation studies of ammonia removal from water in a membrane contactor under liquid-liquid extraction mode.

    Science.gov (United States)

    Mandowara, Amish; Bhattacharya, Prashant K

    2011-01-01

    Simulation studies were carried out, in an unsteady state, for the removal of ammonia from water via a membrane contactor. The contactor had an aqueous solution of NH(3) in the lumen and sulphuric acid in the shell side. The model equations were developed considering radial and axial diffusion and convection in the lumen. The partial differential equations were converted by the finite difference technique into a series of stiff ordinary differential equations w.r.t. time and solved using MATLAB. Excellent agreement was observed between the simulation results and experimental data (from the literature) for a contactor of 75 fibres. Excellent agreement was also observed between the simulation results and laboratory-generated data from a contactor containing 10,200 fibres. Our model is more suitable than the plug-flow model for designing the operation of the membrane contactor. The plug-flow model over-predicts the fractional removal of ammonia and was observed to be limited when designing longer contactors.

  19. Simulation studies of ammonia removal from water in a membrane contactor under liquid-liquid extraction mode.

    Science.gov (United States)

    Mandowara, Amish; Bhattacharya, Prashant K

    2011-01-01

    Simulation studies were carried out, in an unsteady state, for the removal of ammonia from water via a membrane contactor. The contactor had an aqueous solution of NH(3) in the lumen and sulphuric acid in the shell side. The model equations were developed considering radial and axial diffusion and convection in the lumen. The partial differential equations were converted by the finite difference technique into a series of stiff ordinary differential equations w.r.t. time and solved using MATLAB. Excellent agreement was observed between the simulation results and experimental data (from the literature) for a contactor of 75 fibres. Excellent agreement was also observed between the simulation results and laboratory-generated data from a contactor containing 10,200 fibres. Our model is more suitable than the plug-flow model for designing the operation of the membrane contactor. The plug-flow model over-predicts the fractional removal of ammonia and was observed to be limited when designing longer contactors. PMID:20843596

  20. Dual-Band Annular-Ring Microstrip Patch Antenna for Satellite Applications

    Directory of Open Access Journals (Sweden)

    Tvs Divakar

    2014-08-01

    Full Text Available A dual-band circularly polarized antenna fed by four apertures that covers the bands of GPS, Galileo, is introduced. The ARSAs designed using FR4 substrates in the L and S bands have 3-dB axial-ratio bandwidths (ARBWs of as large as 37% and 52%, respectively, whereas the one using an RT5880 substrate in the L band, 61%. In these 3-dB axial-ratio bands, impedance matching with VSWR<=1.8 is also achieved. Three wideband planar baluns are used to achieve good axial ratio and VSWR. The results of the annular-ring microstrip antenna show good performance of a dual-band operation, which meets the requirement of Global Navigation Satellite System (GNSS applications.

  1. Facility modernization Annular Core Research Reactor

    International Nuclear Information System (INIS)

    The Annular Core Research Reactor (ACRR) has undergone numerous modifications since its conception in response to program needs. The original reactor fuel, which was special U-ZrH TRIGA fuel designed primarily for pulsing, has been replaced with a higher pulsing capacity BeO fuel. Other advanced operating modes which use this increased capability, in addition to the pulse and steady state, have been incorporated to tailor power histories and fluences to the experiments. Various experimental facilities have been developed that range from a radiography facility to a 50 cm diameter External Fuel Ring Cavity (FREC) using 180 of the original ZrH fuel elements. Currently a digital reactor console is being produced with GA, which will give enhanced monitoring capabilities of the reactor parameters while leaving the safety-related shutdown functions with analog technology. (author)

  2. Annular MHD Physics for Turbojet Energy Bypass

    Science.gov (United States)

    Schneider, Steven J.

    2011-01-01

    The use of annular Hall type MHD generator/accelerator ducts for turbojet energy bypass is evaluated assuming weakly ionized flows obtained from pulsed nanosecond discharges. The equations for a 1-D, axisymmetric MHD generator/accelerator are derived and numerically integrated to determine the generator/accelerator performance characteristics. The concept offers a shockless means of interacting with high speed inlet flows and potentially offers variable inlet geometry performance without the complexity of moving parts simply by varying the generator loading parameter. The cycle analysis conducted iteratively with a spike inlet and turbojet flying at M = 7 at 30 km altitude is estimated to have a positive thrust per unit mass flow of 185 N-s/kg. The turbojet allowable combustor temperature is set at an aggressive 2200 deg K. The annular MHD Hall generator/accelerator is L = 3 m in length with a B(sub r) = 5 Tesla magnetic field and a conductivity of sigma = 5 mho/m for the generator and sigma= 1.0 mho/m for the accelerator. The calculated isentropic efficiency for the generator is eta(sub sg) = 84 percent at an enthalpy extraction ratio, eta(sub Ng) = 0.63. The calculated isentropic efficiency for the accelerator is eta(sub sa) = 81 percent at an enthalpy addition ratio, eta(sub Na) = 0.62. An assessment of the ionization fraction necessary to achieve a conductivity of sigma = 1.0 mho/m is n(sub e)/n = 1.90 X 10(exp -6), and for sigma = 5.0 mho/m is n(sub e)/n = 9.52 X 10(exp -6).

  3. Recurrent Annular Peripheral Choroidal Detachment after Trabeculectomy

    Directory of Open Access Journals (Sweden)

    Shaohui Liu

    2013-10-01

    Full Text Available We report a challenging case of recurrent flat anterior chamber without hypotony after trabeculectomy in a 54-year-old Black male with a remote history of steroid-treated polymyositis, cataract surgery, and uncontrolled open angle glaucoma. The patient presented with a flat chamber on postoperative day 11, but had a normal fundus exam and intraocular pressure (IOP. Flat chamber persisted despite treatment with cycloplegics, steroids, and a Healon injection into the anterior chamber. A transverse B-scan of the peripheral fundus revealed a shallow annular peripheral choroidal detachment. The suprachoroidal fluid was drained. The patient presented 3 days later with a recurrent flat chamber and an annular peripheral choroidal effusion. The fluid was removed and reinforcement of the scleral flap was performed with the resolution of the flat anterior chamber. A large corneal epithelial defect developed after the second drainage. The oral prednisone was tapered quickly and the topical steroid was decreased. One week later, his vision decreased to count fingers with severe corneal stromal edema and Descemet's membrane folds that improved to 20/50 within 24 h of resumption of the oral steroid and frequent topical steroid. The patient's visual acuity improved to 20/20 following a slow withdrawal of the oral and topical steroid. Eight months after surgery, the IOP was 15 mm Hg without glaucoma medication. The detection of a shallow anterior choroidal detachment by transverse B-scan is critical to making the correct diagnosis. Severe cornea edema can occur if the steroid is withdrawn too quickly. Thus, steroids should be tapered cautiously in steroid-dependent patients.

  4. Centrifuge pellet injector for JET

    International Nuclear Information System (INIS)

    An engineering design of a centrifuge pellet injector for JET is reported as part of the Phase I contract number JE 2/9016. A rather detailed design is presented for the mechanical and electronic features. Stress calculations, dynamic behaviour and life estimates are considered. The interfaces to the JET vacuum system and CODAS are discussed. Proposals for the pellet diagnostics (velocity, mass and shape) are presented. (orig.)

  5. Centrifugal pumps and allied machinery

    CERN Document Server

    Anderson, HH

    1994-01-01

    This book will be of vital interest to all engineers and designers concerned with centrifugal pumps and turbines. Including statistical information derived from 20000 pumps and 700 turbines with capacities of 5gpm to 5000000gpm, this book offers the widest range and scope of information currently available. Statistical analyses suggest practical methods of increasing pump performance and provide valuable data for new design aspects.

  6. Characteristics of Electromagnetic Pulse Coupling into Annular Apertures

    Directory of Open Access Journals (Sweden)

    Yan-Peng Sun

    2013-11-01

    Full Text Available Electromagnetic pulse (EMP coupling into the annular apertures can disturb or damage much electronic equipment. To enhance electronic system’s  capability of anti-electromagnetic interference, the finite difference time domain method (FDTD was employed to study the characteristics of electromagnetic pulse coupling into the cavity enclosures with annular apertures. The coupling characteristics of annular apertures with different shapes (rectangle, square and circle were discussed. It shows that, in the case of the same aperture area, the coupling energy of electromagnetic pulse into the circular annular aperture is smaller than that into the rectangular and the square ones. To the rectangular annular aperture, while the polarization direction of the incident electromagnetic pulse is perpendicular to the long side of the rectangular annular aperture, the coupling energy is larger when the aspect ratio of the rectangular annular aperture is larger. The coupling effect of incident pulse with short pulse width is obviously better than the one with longer pulse width. The resonance phenomenon of the coupled waveform occurs in the cavity.

  7. EFFECT OF ORGANIC LOADING RATES FOR TREATING GREY WATER IN ROTATING BIOLOGICAL CONTACTORS

    Directory of Open Access Journals (Sweden)

    S. Syed Enayathali

    2012-05-01

    Full Text Available The laboratory model of two-stage Rotating Biological Contactor (RBC which was used in the present study is a modified one, with a rovision to vary the speed of rotating blades. Grey wastewater was used to study the performance of the modified rotating biological contactor. The reactor had four rotating blades in each stage, having the size of 300 mm x100 mm x 10 mm, attached perpendicular to the shaft. The experiment was conducted for different influent COD loads and different speeds of rotating blades. Among the different speedsof rotational blades in treating grey water, the rotational speed of 3 rpm was found to yield better percent removal of COD at 95.07% as maximum, where as against the rotational speeds of 4.5 and 6 rpm, the treatment efficiency is 95.04% and 94.96% respectively

  8. An air-liquid contactor for large-scale capture of CO2 from air.

    Science.gov (United States)

    Holmes, Geoffrey; Keith, David W

    2012-09-13

    We present a conceptually simple method for optimizing the design of a gas-liquid contactor for capture of carbon dioxide from ambient air, or 'air capture'. We apply the method to a slab geometry contactor that uses components, design and fabrication methods derived from cooling towers. We use mass transfer data appropriate for capture using a strong NaOH solution, combined with engineering and cost data derived from engineering studies performed by Carbon Engineering Ltd, and find that the total costs for air contacting alone-no regeneration-can be of the order of $60 per tonne CO(2). We analyse the reasons why our cost estimate diverges from that of other recent reports and conclude that the divergence arises from fundamental design choices rather than from differences in costing methodology. Finally, we review the technology risks and conclude that they can be readily addressed by prototype testing.

  9. Method of reliability tolerance design based on EDA technology and its application on DC hybrid contactor

    Institute of Scientific and Technical Information of China (English)

    WANG Shu-juan; SHA You-tao; ZHANG Hui; ZHAI Guo-fu

    2007-01-01

    Tolerance design, including tolerance analysis and distribution, is an important part of the electronic system's reliability design. The traditional design needs to construct mathematic model of material circuit, which involves large amount of workload and lacks of practicability. This paper discusses the basic theory of electronic system's reliability tolerance design and presents a new design method based on EDA (Electronic Design Automatic) software. This method has been validated through the application research on reliability tolerance design of the DC hybrid contactor's control circuit.

  10. Liposome and niosome preparation using a membrane contactor for scale-up.

    Science.gov (United States)

    Pham, Thi Thuy; Jaafar-Maalej, Chiraz; Charcosset, Catherine; Fessi, Hatem

    2012-06-01

    The scaling-up ability of liposome and niosome production, from laboratory scale using a syringe-pump device to a pilot scale using the membrane contactor module, was investigated. For this aim, an ethanol injection-based method was applied for liposome and niosome preparation. The syringe-pump device was used for laboratory scale batches production (30 ml for liposomes, 20 ml for niosomes) then a pilot scale (750 ml for liposomes, 1000 ml for niosomes) were obtained using the SPG membrane contactor. Resulted nanovesicles were characterized in terms of mean vesicles size, polydispersity index (PdI) and zeta potential. The drug encapsulation efficiency (E.E.%) was evaluated using two drug-models: caffeine and spironolactone, a hydrophilic and a lipophilic molecule, respectively. As results, nanovectors mean size using the syringe-pump device was comprised between 82 nm and 95 nm for liposomes and between 83 nm and 127 nm for niosomes. The optimal E.E. of caffeine within niosomes, was found around 9.7% whereas the spironolactone E.E. reached 95.6% which may be attributed to its lipophilic properties. For liposomes these values were about 9.7% and 86.4%, respectively. It can be clearly seen that the spironolactone E.E. was slightly higher within niosomes than liposomes. Optimized formulations, which offered smaller size and higher E.E., were selected for pilot scale production using the SPG membrane. It has been found that vesicles characteristics (size and E.E.%) were reproducible using the membrane contactor module. Thus, the current study demonstrated the usefulness of the membrane contactor as a device for scaling-up both liposome and niosome preparations with small mean sizes.

  11. Mechanical evolution of the rotating biological contactor into the 21st century.

    OpenAIRE

    Mba, David

    2003-01-01

    This paper presents a review on the evolution of the mechanical design of rotating biological contactors (RBCs) within the UK. The findings documented have been taken from the biggest mechanical survey on RBCs ever undertaken worldwide and focuses on 300 operational units. The paper looks at the main components of the RBC and discusses the evolution of each member. Mechanical deficiencies associated with each design are briefly presented, giving an insight into reasons for i...

  12. Detonation Initiation by Annular Jets and Shock Waves

    OpenAIRE

    Shepherd, Joseph E.

    2005-01-01

    The objective of this research is to experimentally determine the feasibility of initiating detonation in fuel-air mixtures using only the energy in hot, compressed air. The existing 6-inch shock tube at Caltech was used to create hot, high-pressure air behind a reflected shock wave. The hot air created an imploding annular shock wave when it jetted through an annular orifice into a 76-mm-diameter, 1-m-long tube attached to the end of the shock tube. A special test section with an annular ...

  13. Radiation and reflection acoustical fields of an annular phased array

    Institute of Scientific and Technical Information of China (English)

    LAI Puxiang; ZHANG Bixing; WANG Chenghao

    2007-01-01

    The characteristics of the radiation and reflection acoustical fields of an annular phased array are investigated. The effects of the element number, element radius, interelement spacing, centre frequency, focus position, and other parameters on the radiation acoustical field of the annular phased array is theoretically studied. In experiment, an annular transducer with 8 equal-area elements is designed and fabricated, and a series of experimental measurements are conducted. The radiation acoustical field and its reflection on a liquid-solid interface are theoretically and experimentally studied. The experimental result is in good agreement with the theoretical one.

  14. Triple-bore hollow fiber membrane contactor for liquid desiccant based air dehumidification

    KAUST Repository

    Bettahalli, N.M. Srivatsa

    2016-04-26

    Dehumidification is responsible for a large part of the energy consumption in cooling systems in high humidity environments worldwide. Improving efficiency is therefore essential. Liquid desiccants offer a promising solution for dehumidification, as desired levels of humidity removal could be easily regulated. The use of membrane contactors in combination with liquid desiccant is attractive for dehumidification because they prevent direct contact between the humid air and the desiccant, removing both the potential for desiccant carryover to the air and the potential for contamination of the liquid desiccant by dust and other airborne materials, as well as minimizing corrosion. However, the expected additional mass transport barrier of the membrane surface can lower the expected desiccation rate per unit of desiccant surface area. In this context, hollow fiber membranes present an attractive option for membrane liquid desiccant contactors because of their high surface area per unit volume. We demonstrate in this work the performance of polyvinylidene fluoride (PVDF) based triple-bore hollow fiber membranes as liquid desiccant contactors, which are permeable to water vapor but impermeable to liquid water, for dehumidification of hot and humid air.

  15. Extraction and quantification of SO2 content in wines using a hollow fiber contactor.

    Science.gov (United States)

    Plaza, Andrea; Romero, Julio; Silva, Wladimir; Morales, Elizabeth; Torres, Alejandra; Aguirre, María J

    2014-10-01

    Sulfites [Formula: see text] or sulfur dioxide (SO2) is a preservative widely used in fruits and fruit-derived products. This study aims to propose a membrane contactor process for the selective removal and recovery of SO2 from wines in order to obtain its reliable quantification. Currently, the aspiration and Ripper methods offer a difficult quantification of the sulfite content in red wines because they involve evaporation steps of diluted compounds and a colorimetric assay, respectively. Therefore, an inexpensive and accurate methodology is not currently available for continuous monitoring of SO2 in the liquids food industry. Red wine initially acidified at pH Contactor, which separates the acidified red wine in the shell side and a diluted aqueous sodium hydroxide solution as receiving solution into the lumenside in countercurrent. Sulfite and bisulfite in the acidified red wine become molecular SO2, which is evaporated through the membrane pores filled with gas. Thus, SO2 is trapped in a colorless solution and the membrane contactor controls its transfer, decreasing experimental error induced in classical methods. Experimental results using model solutions with known concentration values of [Formula: see text] show an average extraction percentage of 98.91 after 4 min. On the other hand, two types of Chilean Cabernet Sauvignon wines were analyzed with the same system to quantify the content of free and total sulfites. Results show a good agreement between these methods and the proposed technique, which shows a lower experimental variability.

  16. THC1系列交流接触器%THC1 Series AC Contactor

    Institute of Scientific and Technical Information of China (English)

    夏芳娟; 曾萍; 陈红; 陈晓军

    2009-01-01

    介绍了THC1系列交流接触器.从技术参数、结构特点、创新点及材料方面介绍了该接触器的主要特征.新产品采用热塑件以利环保,采用塑料卡扣拼装和端子罩盖便于装配,将原有限的空间分割出若十小室,互不干扰,保证了工作时期的可靠绝缘及安全.%The THC1 AC contactor was introduced.The main traits of this contactor,such as technology,structure point,innovation points and material,were introduced.Thermal plastic was adopted to protect environ-ment.Plastic block buckle and terminal cover were adopted to assemble conveniently.Primary finite space was di-vided into several small cells so that they didn't interfere each other,with ensuring reliable insulation and safety when contactor works.

  17. Centrifuge facilities at Technical University of Denmark

    DEFF Research Database (Denmark)

    Leth, Caspar Thrane; Krogsbøll, Anette Susanne; Hededal, Ole

    2008-01-01

    The geotechnical group at the Danish Technical University (DTU) operates a geotechnical beam centrifuge. The centrifuge was build in 1976 and has been upgraded through the years, latest with onboard data and control systems. The centrifuge concept involves an increased gravity field in which...... the physical model is placed and tested. The capabilities of the centrifuge at DTU makes it possible to obtain a scale factor of 75-85 in the tests which equals a soil volume in prototype scale of ø40m and a depth of 36 m. The centrifuge facilities at DTU have through the years been used for testing various...... geotechnical issues, such as suction anchors, tension piles in clay, active earth pressures on sheet piles and group effects for lateral loaded piles. The paper describes physical modelling in general, the centrifuge, present setups and shows samples of obtained results....

  18. Empirical Design Considerations for Industrial Centrifugal Compressors

    Directory of Open Access Journals (Sweden)

    Cheng Xu

    2012-01-01

    Full Text Available Computational Fluid Dynamics (CFD has been extensively used in centrifugal compressor design. CFD provides further optimisation opportunities for the compressor design rather than designing the centrifugal compressor. The experience-based design process still plays an important role for new compressor developments. The wide variety of design subjects represents a very complex design world for centrifugal compressor designers. Therefore, some basic information for centrifugal design is still very important. The impeller is the key part of the centrifugal stage. Designing a highly efficiency impeller with a wide operation range can ensure overall stage design success. This paper provides some empirical information for designing industrial centrifugal compressors with a focus on the impeller. A ported shroud compressor basic design guideline is also discussed for improving the compressor range.

  19. Principle of radial transport in low temperature annular plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yunchao, E-mail: yunchao.zhang@anu.edu.au; Charles, Christine; Boswell, Rod [Space Plasma, Power and Propulsion Laboratory, Research School of Physics and Engineering, The Australian National University, Bldg 60, Mills Road, Australian Capital Territory 2601 (Australia)

    2015-07-15

    Radial transport in low temperature annular plasmas is investigated theoretically in this paper. The electrons are assumed to be in quasi-equilibrium due to their high temperature and light inertial mass. The ions are not in equilibrium and their transport is analyzed in three different situations: a low electric field (LEF) model, an intermediate electric field (IEF) model, and a high electric field (HEF) model. The universal IEF model smoothly connects the LEF and HEF models at their respective electric field strength limits and gives more accurate results of the ion mobility coefficient and effective ion temperature over the entire electric field strength range. Annular modelling is applied to an argon plasma and numerical results of the density peak position, the annular boundary loss coefficient and the electron temperature are given as functions of the annular geometry ratio and Paschen number.

  20. Effect of Centrifugation on Sesame Paste Temperature

    Directory of Open Access Journals (Sweden)

    Ahmad Kouchakzadeh

    2012-01-01

    Full Text Available The sesame seeds were mechanically cold pressed at temperature below 45 then centrifuged. No chemicals were used. The temperature during centrifugation of sesame paste was recorded. Temperatures in less than one hour operation has elevated to 148, 273 and 315 in 1200, 1800 and 2400 G-force centrifugal acceleration, respectively. since the centrifugal accelerations during the process cut at 1200, 1800 and 2400 G-force at about 35, 20 and 10 minutes, respectively. The maximum allowable temperatures raised to about 100 . Linear and quadratics regression model were fitted to data.

  1. Centrifugal separators and related devices and methods

    Science.gov (United States)

    Meikrantz, David H.; Law, Jack D.; Garn, Troy G.; Macaluso, Lawrence L.; Todd, Terry A.

    2012-03-06

    Centrifugal separators and related methods and devices are described. More particularly, centrifugal separators comprising a first fluid supply fitting configured to deliver fluid into a longitudinal fluid passage of a rotor shaft and a second fluid supply fitting sized and configured to sealingly couple with the first fluid supply fitting are described. Also, centrifugal separator systems comprising a manifold having a drain fitting and a cleaning fluid supply fitting are described, wherein the manifold is coupled to a movable member of a support assembly. Additionally, methods of cleaning centrifugal separators are described.

  2. Cavitation Effects in Centrifugal Pumps- A Review

    Directory of Open Access Journals (Sweden)

    Maxime Binama

    2016-05-01

    Full Text Available Cavitation is one of the most challenging fluid flow abnormalities leading to detrimental effects on both the centrifugal pump flow behaviors and physical characteristics. Centrifugal pumps’ most low pressure zones are the first cavitation victims, where cavitation manifests itself in form of pitting on the pump internal solid walls, accompanied by noise and vibration, all leading to the pump hydraulic performance degradation. In the present article, a general description of centrifugal pump performance and related parameters is presented. Based on the literature survey, some light were shed on fundamental cavitation features; where different aspects relating to cavitation in centrifugal pumps were briefly discussed

  3. Virgin Coconut Oil Production by Centrifugation Method

    Directory of Open Access Journals (Sweden)

    Y.C.Wong

    2014-03-01

    Full Text Available The virgin coconut oil (VCO production by centrifugation method was studied. The production of VCO was studied by using various centrifugation speed, temperature and time intervals. The results showed that the yield of VCO was 13.53% at 12000rpm, at 120 minutes. The highest yield of VCO was 13.80% at centrifugation temperature of 40oC. The concentration of lauric acid present in the samples with variables of centrifugation temperatures, speed, and time intervals were 0.4543µg, 6.2367µg, and 6.4894µg respectively.

  4. CFD simulation of centrifugal cells washers.

    Science.gov (United States)

    Kellet, Beth E; Binbing, Han; Dandy, David S; Wickramasinghe, S Ranil

    2004-01-01

    The feasibility of using computational fluid dynamics to guide the design of better centrifuges for processing shed blood is explored here. The velocity field and the rate of protein removal from the shed blood have been studied. The results indicate that computational fluid dynamics could help screen preliminary centrifuge bowl designs thus reducing the number of initial experimental tests required when developing new centrifuge bowls. Though the focus of this work is on washing shed blood the methods developed here are applicable to the design of centrifuge bowls for other blood processing applications. PMID:15133962

  5. Centrifugal quantum states of neutrons

    Science.gov (United States)

    Nesvizhevsky, V. V.; Petukhov, A. K.; Protasov, K. V.; Voronin, A. Yu.

    2008-09-01

    We propose a method for observation of the quasistationary states of neutrons localized near a curved mirror surface. The bounding effective well is formed by the centrifugal potential and the mirror Fermi potential. This phenomenon is an example of an exactly solvable “quantum bouncer” problem that can be studied experimentally. It could provide a promising tool for studying fundamental neutron-matter interactions, as well as quantum neutron optics and surface physics effects. We develop a formalism that describes quantitatively the neutron motion near the mirror surface. The effects of mirror roughness are taken into account.

  6. Annular bright and dark field imaging of soft materials

    International Nuclear Information System (INIS)

    Here polyethylene, as an example of an important soft material, was studied by STEM annular bright and dark field. The contrast as function of the probe size/shape and the detector collection angle are discussed. The results are compared to conventional bright field transmission electron microscopy, electron energy filtered imaging and energy dispersive spectroscopy mapping. Annular bright and dark field gave a higher contrast than conventional transmission and analytical mapping techniques

  7. New mitral annular force transducer optimized to distinguish annular segments and multi-plane forces.

    Science.gov (United States)

    Skov, Søren Nielsen; Røpcke, Diana Mathilde; Ilkjær, Christine; Rasmussen, Jonas; Tjørnild, Marcell Juan; Jimenez, Jorge H; Yoganathan, Ajit P; Nygaard, Hans; Nielsen, Sten Lyager; Jensen, Morten Olgaard

    2016-03-21

    Limited knowledge exists about the forces acting on mitral valve annuloplasty repair devices. The aim of this study was to develop a new mitral annular force transducer to measure the forces acting on clinically used mitral valve annuloplasty devices. The design of an X-shaped transducer in the present study was optimized for simultaneous in- and out-of-plane force measurements. Each arm was mounted with strain gauges on four circumferential elements to measure out-of-plane forces, and the central parts of the X-arms were mounted with two strain gauges to measure in-plane forces. A dedicated calibration setup was developed to calibrate isolated forces with tension and compression for in- and out-of-plane measurements. With this setup, it was possible with linear equations to isolate and distinguish measured forces between the two planes and minimize transducer arm crosstalk. An in-vitro test was performed to verify the crosstalk elimination method and the assumptions behind it. The force transducer was implanted and evaluated in an 80kg porcine in-vivo model. Following crosstalk elimination, in-plane systolic force accumulation was found to be in average 4.0±0.1N and the out-of-plane annular segments experienced an average force of 1.4±0.4N. Directions of the systolic out-of-plane forces indicated movements towards a saddle shaped annulus, and the transducer was able to measure independent directional forces in individual annular segments. Further measurements with the new transducer coupled with clinical annuloplasty rings will provide a detailed insight into the biomechanical dynamics of these devices. PMID:26903412

  8. New mitral annular force transducer optimized to distinguish annular segments and multi-plane forces.

    Science.gov (United States)

    Skov, Søren Nielsen; Røpcke, Diana Mathilde; Ilkjær, Christine; Rasmussen, Jonas; Tjørnild, Marcell Juan; Jimenez, Jorge H; Yoganathan, Ajit P; Nygaard, Hans; Nielsen, Sten Lyager; Jensen, Morten Olgaard

    2016-03-21

    Limited knowledge exists about the forces acting on mitral valve annuloplasty repair devices. The aim of this study was to develop a new mitral annular force transducer to measure the forces acting on clinically used mitral valve annuloplasty devices. The design of an X-shaped transducer in the present study was optimized for simultaneous in- and out-of-plane force measurements. Each arm was mounted with strain gauges on four circumferential elements to measure out-of-plane forces, and the central parts of the X-arms were mounted with two strain gauges to measure in-plane forces. A dedicated calibration setup was developed to calibrate isolated forces with tension and compression for in- and out-of-plane measurements. With this setup, it was possible with linear equations to isolate and distinguish measured forces between the two planes and minimize transducer arm crosstalk. An in-vitro test was performed to verify the crosstalk elimination method and the assumptions behind it. The force transducer was implanted and evaluated in an 80kg porcine in-vivo model. Following crosstalk elimination, in-plane systolic force accumulation was found to be in average 4.0±0.1N and the out-of-plane annular segments experienced an average force of 1.4±0.4N. Directions of the systolic out-of-plane forces indicated movements towards a saddle shaped annulus, and the transducer was able to measure independent directional forces in individual annular segments. Further measurements with the new transducer coupled with clinical annuloplasty rings will provide a detailed insight into the biomechanical dynamics of these devices.

  9. Annular burnout data from rod bundle experiments

    International Nuclear Information System (INIS)

    Burnout data for annular flow in a rod bundle are presented for both transient and steady-state conditions. Tests were performed at the Oak Ridge National Laboratory in the Thermal Hydraulic Test Facility (THTF), a pressurized-water loop containing an electrically heated 64-rod bundle. The bundle configuration is typical of later generation pressurized-water reactors with 17 x 17 fuel arrays. Both axial and radial power profiles are flat. All experiments were carried out in upflow with subcooled inlet conditions, insuring accurate flow measurement. Conditions within the bundle were typical of those which could be encountered during a nuclear reactor loss-of-coolant accident. Level average fluid conditions within the test section were calculated using steady-state mass and energy conservation considerations for the steady-state tests and a transient, homogeneous, equilibrium computer code for the transient tests. Unlike tube dryout, burnout within a rod bundle does not necessarily occur at one distinct axial level. The location of individual rod dryout was determined by scanning rods axially and locating the position where rod superheat increased from approx. =0 to 30 K or greater. Thermocouple instrumentation within the bundle allows the location of dryout to be determined to within approximately +.5 cm for many of the tests

  10. PUMA - a new mathematical model for the rapid calculation of steady-state concentration profiles in mixer-settler extraction, partitioning, and stripping contactors using the Purex process

    International Nuclear Information System (INIS)

    The mathematical basis for a computer code PUMA (Plutonium-Uranium-Matrix-Algorithm) is described. The code simulates steady-state concentration profiles of solvent extraction contactors used in the Purex process, directly without first generating the transient behavior. The computational times are reduced, with no loss of accuracy, by about tenfold over those required by codes that generate the steady-state profiles via transient state conditions. Previously developed codes that simulate the steady-state conditions directly are not applicable to partitioning contactors, whereas PUMA is applicable to all contactors in the Purex process. Since most difficulties are encountered with partitioning contactors when simulating steady-state profiles via transient state conditions, it is with these contactors that the greatest saving in computer times is achieved

  11. X-ray diffraction from bone employing annular and semi-annular beams

    International Nuclear Information System (INIS)

    There is a compelling need for accurate, low cost diagnostics to identify osteo-tissues that are associated with a high risk of fracture within an individual. To satisfy this requirement the quantification of bone characteristics such as ‘bone quality’ need to exceed that provided currently by densitometry. Bone mineral chemistry and microstructure can be determined from coherent x-ray scatter signatures of bone specimens. Therefore, if these signatures can be measured, in vivo, to an appropriate accuracy it should be possible by extending terms within a fracture risk model to improve fracture risk prediction.In this preliminary study we present an examination of a new x-ray diffraction technique that employs hollow annular and semi-annular beams to measure aspects of ‘bone quality’. We present diffractograms obtained with our approach from ex vivo bone specimens at Mo Kα and W Kα energies. Primary data is parameterized to provide estimates of bone characteristics and to indicate the precision with which these can be determined. (paper)

  12. Centrifuge modelling of offshore monopile foundation

    DEFF Research Database (Denmark)

    Klinkvort, Rasmus Tofte; Hededal, Ole

    2010-01-01

    centrifuge tests on a laterally loaded monopile in dry sand. The prototype dimension of the piles was modelled to a diameter of 1 meter and penetration depth on 6 meter. The test series were designed in order to investigate the scaling laws in the centrifuge both for monotonic and cyclic loading...

  13. Centrifugal innervation of the mammalian olfactory bulb.

    Science.gov (United States)

    Matsutani, Shinji; Yamamoto, Noboru

    2008-12-01

    Although it has been known for decades that the mammalian olfactory bulb receives a substantial number of centrifugal inputs from other regions of the brain, relatively few data have been available on the function of the centrifugal olfactory system. Knowing the role of the centrifugal projection and how it works is of critical importance to fully understanding olfaction. The centrifugal fibers can be classified into two groups, a group that release neuromodulators, such as noradrenaline, serotonin, or acetylcholine, and a group originating in the olfactory cortex. Accumulating evidence suggests that centrifugal neuromodulatory inputs are associated with acquisition of odor memory. Because the distribution of the terminals on these fibers is diffuse and widespread, the neuromodulatory inputs must affect diverse subsets of bulbar neurons at the same time. In contrast, knowledge of the role of centrifugal fibers from the olfactory cortical areas is limited. Judging from recent morphological evidence, these fibers may modify the activity of neurons located in sparse and discrete loci in the olfactory bulb. Given the modular organization of the olfactory bulb, centrifugal fibers from the olfactory cortex may help coordinate the activities of restricted subsets of neurons belonging to distinct functional modules in an odor-specific manner. Because the olfactory cortex receives inputs from limbic and neocortical areas in addition to inputs from the bulb, the centrifugal inputs from the cortex can modulate odor processing in the bulb in response to non-olfactory as well as olfactory cues.

  14. Detection methods for centrifugal microfluidic platforms

    DEFF Research Database (Denmark)

    Burger, Robert; Amato, Letizia; Boisen, Anja

    2016-01-01

    Centrifugal microfluidics has attracted much interest from academia as well as industry, since it potentially offers solutions for affordable, user-friendly and portable biosensing. A wide range of so-called fluidic unit operations, e.g. mixing, metering, liquid routing, and particle separation...... for the centrifugal microfluidics platform and cover optical as well as mechanical and electrical detection principles....

  15. High frequency dynamics in centrifugal compressors

    NARCIS (Netherlands)

    Twerda, A.; Meulendijks, D.; Smeulers, J.P.M.; Handel, R. van den; Lier, L.J. van

    2008-01-01

    Problems with centrifugal compressors relating to high frequency, i.e. Blade passing frequency (BPF) are increasing. Pulsations and vibrations generated in centrifugal compressors can lead to nuisance, due to strong tonal noise, and even breakdown. In several cases the root cause of a failure or a n

  16. Rotor for a pyrolysis centrifuge reactor

    DEFF Research Database (Denmark)

    2015-01-01

    The present invention relates to a rotor for a pyrolysis centrifuge reactor, said rotor comprising a rotor body having a longitudinal centre axis, and at least one pivotally mounted blade being adapted to pivot around a pivot axis under rotation of the rotor body around the longitudinal centre axis....... Moreover, the present invention relates to a pyrolysis centrifuge reactor applying such a rotor....

  17. Control system modeling of a centrifuge

    International Nuclear Information System (INIS)

    Improved control of a centrifuge can be achieved by using a mathematical model. This model is a linear, time-invariant, second order model which relates the input to the output of the centrifuge. After the Z-transform of the model was taken, a digital computer program was written to implement the model. The model parameters were optimized through correlation of the theoretical output as compared with the actual output of the centrifuge. As a result, a model was developed that simulated the centrifuge. Traditionally, a desired centrifuge output was produced by an input which was determined by trial and error. However, using the model with the desired output curve, the necessary input can be calculated with the digital computer program

  18. Sea Carousel—A benthic, annular flume

    Science.gov (United States)

    Amos, Carl L.; Grant, J.; Daborn, G. R.; Black, K.

    1992-06-01

    A benthic annular flume (Sea Carousel) has been developed and tested to measure in situ the erodibility of cohesive sediments. The flume is equipped with three optical backscatter sensors, a lid rotation switch, and an electromagnetic (EM) flow meter capable of detecting azimuthal and vertical components of flow. Data are logged at rates up to 10·66 Hz. Erodibility is inferred from the rate of change in suspended sediment concentration detected in the annulus. The energy-density/wave number spectrum of azimuthal flow showed peaks in the energy spectrum at paddle rotation wave numbers (k) of 14 and 7 m -1 (macroturbulent time scales) but were not significant. Friction velocity ( U*), measured (1) at 1 Hz using a flush-mounted hot-film sensor, and (2) derived from measured velocity profiles in the inner part of the logarithmic layer gave comparable results for Ū* 0·32 m s -1. Radial velocity gradients were proportional to ( Ū y - 0·32 m s -1). Maximum radial differences in U* were 10% for Ū y = 0·5 ms -1. Suspended sediment mass concentration ( S) in the annulus resulted in a significant decrease (10·5%) in Ū* derived by method (1) over the range 0calibration with changes in S. Subaerial deployments of Sea Carousel caused severe substrate disturbance, water losses, and aeration of the annulus. Submarine deployments produced stable results, though dispersion of turbid flume water took place. Results clearly demonstrated the existence of 'Type I' and 'Type II' erosion documented from laboratory studies.

  19. DETERMINATION OF LIQUID FILM THICKNESS FOLLOWING DRAINING OF CONTACTORS, VESSELS, AND PIPES IN THE MCU PROCESS

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, M; Fernando Fondeur, F; Samuel Fink, S

    2006-06-06

    The Department of Energy (DOE) identified the caustic side solvent extraction (CSSX) process as the preferred technology to remove cesium from radioactive waste solutions at the Savannah River Site (SRS). As a result, Washington Savannah River Company (WSRC) began designing and building a Modular CSSX Unit (MCU) in the SRS tank farm to process liquid waste for an interim period until the Salt Waste Processing Facility (SWPF) begins operations. Both the solvent and the strip effluent streams could contain high concentrations of cesium which must be removed from the contactors, process tanks, and piping prior to performing contactor maintenance. When these vessels are drained, thin films or drops will remain on the equipment walls. Following draining, the vessels will be flushed with water and drained to remove the flush water. The draining reduces the cesium concentration in the vessels by reducing the volume of cesium-containing material. The flushing, and subsequent draining, reduces the cesium in the vessels by diluting the cesium that remains in the film or drops on the vessel walls. MCU personnel requested that Savannah River National Laboratory (SRNL) researchers conduct a literature search to identify models to calculate the thickness of the liquid films remaining in the contactors, process tanks, and piping following draining of salt solution, solvent, and strip solution. The conclusions from this work are: (1) The predicted film thickness of the strip effluent is 0.010 mm on vertical walls, 0.57 mm on horizontal walls and 0.081 mm in horizontal pipes. (2) The predicted film thickness of the salt solution is 0.015 mm on vertical walls, 0.74 mm on horizontal walls, and 0.106 mm in horizontal pipes. (3) The predicted film thickness of the solvent is 0.022 mm on vertical walls, 0.91 mm on horizontal walls, and 0.13 mm in horizontal pipes. (4) The calculated film volume following draining is: (a) Salt solution receipt tank--1.6 gallons; (b) Salt solution feed

  20. Design of centrifugal impeller blades

    Science.gov (United States)

    Betz, A; Flugge-Lotz, I

    1939-01-01

    This paper restricts itself to radial impellers with cylindrical blades since, as Prasil has shown, the flow about an arbitrarily curved surface of revolution may be reduced to this normal form we have chosen by a relatively simple conformal transformation. This method starts from the simple hypotheses of the older centrifugal impeller theory by first assuming an impeller with an infinite number of blades. How the flow is then modified is then investigated. For the computation of flow for a finite number of blades, the approximation method as developed by Munk, Prandtl and Birnbaum, or Glauert is found suitable. The essential idea of this method is to replace the wing by a vortex sheet and compute the flow as the field of these vortices. The shape of the blades is then obtained from the condition that the flow must be along the surface of the blade.

  1. Centrifugal membrane filtration - Task 9

    International Nuclear Information System (INIS)

    The Energy and Environmental Research Center (EERC) has teamed with SpinTek Membrane Systems, Inc., the developer of a centrifugal membrane filtration technology, to demonstrate applications for the SpinTek technology within the US Department of Energy (DOE) Environmental management (EM) Program. The technology uses supported microporous membranes rotating at high rpm, under pressure, to separate suspended and colloidal solids from liquid streams, yielding a solids-free permeate stream and a highly concentrated solids stream. This is a crosscutting technology that falls under the Efficient Separations and Processing Crosscutting Program, with potential application to tank wastes, contaminated groundwater, landfill leachate, and secondary liquid waste streams from other remediation processes, including decontamination and decommissioning systems. Membrane-screening tests were performed with the SpinTek STC-X4 static test cell filtration unit, using five ceramic membranes with different pore size and composition. Based on permeate flux, a 0.25-microm TiO2/Al2O3 membrane was selected for detailed performance evaluation using the SpinTek ST-IIL centrifugal membrane filtration unit with a surrogate tank waste solution. An extended test run of 100 hr performed on a surrogate tank waste solution showed some deterioration in filtration performance, based on flux, apparently due to the buildup of solids near the inner portion of the membrane where relative membrane velocities were low. Continued testing of the system will focus on modifications to the shear pattern across the entire membrane surface to affect improved long-term performance

  2. Centrifugal membrane filtration -- Task 9

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-01

    The Energy and Environmental Research Center (EERC) has teamed with SpinTek Membrane Systems, Inc., the developer of a centrifugal membrane filtration technology, to demonstrate applications for the SpinTek technology within the US Department of Energy (DOE) Environmental management (EM) Program. The technology uses supported microporous membranes rotating at high rpm, under pressure, to separate suspended and colloidal solids from liquid streams, yielding a solids-free permeate stream and a highly concentrated solids stream. This is a crosscutting technology that falls under the Efficient Separations and Processing Crosscutting Program, with potential application to tank wastes, contaminated groundwater, landfill leachate, and secondary liquid waste streams from other remediation processes, including decontamination and decommissioning systems. Membrane-screening tests were performed with the SpinTek STC-X4 static test cell filtration unit, using five ceramic membranes with different pore size and composition. Based on permeate flux, a 0.25-{micro}m TiO{sub 2}/Al{sub 2}O{sub 3} membrane was selected for detailed performance evaluation using the SpinTek ST-IIL centrifugal membrane filtration unit with a surrogate tank waste solution. An extended test run of 100 hr performed on a surrogate tank waste solution showed some deterioration in filtration performance, based on flux, apparently due to the buildup of solids near the inner portion of the membrane where relative membrane velocities were low. Continued testing of the system will focus on modifications to the shear pattern across the entire membrane surface to affect improved long-term performance.

  3. Regeneration of Alkanolamine Solutions in Membrane Contactor Based on Novel Polynorbornene

    Directory of Open Access Journals (Sweden)

    Shutova A.A.

    2014-11-01

    Full Text Available For the first time, a novel highly permeable glassy polymer, addition poly[bis(trimethylsilyltricyclononene] (PBTMST, was proposed for its use in a gas-liquid membrane contactor for the regeneration of CO2 absorption liquids (desorption of CO2. This membrane material possesses a good chemical stability and high barrier properties for a number of alkanolmines (30 wt% solutions of MEA, DEA, MDEA, AMP, DEAE or AEAE under typical regeneration conditions (T = 100°C. Studies on gas transport properties of PBTMST (100°C and 1-40 bar show that permeability coefficients of oxygen, nitrogen and carbon dioxide initially tend to decrease, and then level off after first 6-8 hours of operation. This behavior can be explained by partial relaxation of the free-volume structure of PBTMST, no chemical degradation of polymer material at high temperature was confirmed by IR analysis. At the same time, this membrane material preserves high gas permeability coefficients which are higher than those of conventional materials used in the membrane contactors. Gas-liquid membrane contactor based on dense PBTMST membrane shows a good, stable performance; particularly, CO2 loading in diethanolamine solution (30 wt% can be reduced for 0.05-0.34 mole/mole by single pass through the membrane desorber at 100°C and elevated pressure. It seems that desorption rate here is mainly controlled by liquid phase because decreasing of membrane thickness by 50% (from 31 to 21 μm leads to improvement of DEA regeneration only by 1.5-8.5%.

  4. Far-field Diffraction Properties of Annular Walsh Filters

    Directory of Open Access Journals (Sweden)

    Pubali Mukherjee

    2013-01-01

    Full Text Available Annular Walsh filters are derived from the rotationally symmetric annular Walsh functions which form a complete set of orthogonal functions that take on values either +1 or −1 over the domain specified by the inner and outer radii of the annulus. The value of any annular Walsh function is taken as zero from the centre of the circular aperture to the inner radius of the annulus. The three values 0, +1, and −1 in an annular Walsh function can be realized in a corresponding annular Walsh filter by using transmission values of zero amplitude (i.e., an obscuration, unity amplitude and zero phase, and unity amplitude and phase, respectively. Not only the order of the Walsh filter but also the size of the inner radius of the annulus provides an additional degree of freedom in tailoring of point spread function by using these filters for pupil plane filtering in imaging systems. In this report, we present the far-field amplitude characteristics of some of these filters to underscore their potential for effective use in several demanding applications like high-resolution microscopy, optical data storage, microlithography, optical encryption, and optical micromanipulation.

  5. Rotordynamic Analysis of Textured Annular Seals With Multiphase (Bubbly Flow

    Directory of Open Access Journals (Sweden)

    Gérard PINEAU

    2011-09-01

    Full Text Available For some applications it must be considered that the flow in the annular seal contains a mixture of liquid and gas. The multiphase character of the flow is described by the volume fraction of gas (usually air contained in the liquid under the form of bubbles.The fluid is then a homogenous mixture of air and liquid all thru the annular seal. Its local gas volume fraction depends on the pressure field and is calculated by using a simplified form of the Rayleigh-Plesset equation.The influence of such of a multiphase (bubbly flow on the dynamic characteristics of a straight annular seal is minimal because the volume of the fluid is reduced.The situation is quite different for textured annular (damper seals provided with equally spaced deep cavities intended to increase the damping capabilities and to reduce the leakage flow rate.As a by-product, the volume of the fluid in the seal increases drastically and the compressibility effects stemming from the bubbly nature of the flow are largely increased even for a low gas volume fraction. The present work depicts the influence of the gas volume fraction on the dynamic characteristics of a textured annular seal. It is shown that variations of the gas volume fraction between 1% and 0.1% can lead to frequency dependent stiffness, damping and added mass coefficients.

  6. Denitrification in an anoxic rotating biological contactor under two carbon/nitrogen ratios

    OpenAIRE

    Cortez, Susana; Teixeira, P; Oliveira, Rosário; Mota, M.

    2008-01-01

    The aim of the present work was to compare the performance of an anoxic bench-scale rotating biological contactor (RBC), in terms of the denitrification process, applied to treat synthetic wastewater under two carbon/nitrogen (C/N) molar ratios (1.5 and 3). The average removal efficiency in terms of nitrogen-nitrate was of about 90.4% at a C/N=1.5 lowering to 73.7% at a C/N=3. Considering carbon-acetate removal an overall efficiency of 82.0% and 63.6% was attained at a C/N rati...

  7. Centrifuge workers study. Phase II, completion report

    Energy Technology Data Exchange (ETDEWEB)

    Wooten, H.D.

    1994-09-01

    Phase II of the Centrifuge Workers Study was a follow-up to the Phase I efforts. The Phase I results had indicated a higher risk than expected among centrifuge workers for developing bladder cancer when compared with the risk in the general population for developing this same type of cancer. However, no specific agent could be identified as the causative agent for these bladder cancers. As the Phase II Report states, Phase I had been limited to workers who had the greatest potential for exposure to substances used in the centrifuge process. Phase II was designed to expand the survey to evaluate the health of all employees who had ever worked in Centrifuge Program Departments 1330-1339 but who had not been interviewed in Phase I. Employees in analytical laboratories and maintenance departments who provided support services for the Centrifuge Program were also included in Phase II. In December 1989, the Oak Ridge Associated Universities (ORAU), now known as Oak Ridge Institute for Science and Education (ORISE), was contracted to conduct a follow-up study (Phase II). Phase H of the Centrifuge Workers Study expanded the survey to include all former centrifuge workers who were not included in Phase I. ORISE was chosen because they had performed the Phase I tasks and summarized the corresponding survey data therefrom.

  8. Centrifuge workers study. Phase II, completion report

    International Nuclear Information System (INIS)

    Phase II of the Centrifuge Workers Study was a follow-up to the Phase I efforts. The Phase I results had indicated a higher risk than expected among centrifuge workers for developing bladder cancer when compared with the risk in the general population for developing this same type of cancer. However, no specific agent could be identified as the causative agent for these bladder cancers. As the Phase II Report states, Phase I had been limited to workers who had the greatest potential for exposure to substances used in the centrifuge process. Phase II was designed to expand the survey to evaluate the health of all employees who had ever worked in Centrifuge Program Departments 1330-1339 but who had not been interviewed in Phase I. Employees in analytical laboratories and maintenance departments who provided support services for the Centrifuge Program were also included in Phase II. In December 1989, the Oak Ridge Associated Universities (ORAU), now known as Oak Ridge Institute for Science and Education (ORISE), was contracted to conduct a follow-up study (Phase II). Phase H of the Centrifuge Workers Study expanded the survey to include all former centrifuge workers who were not included in Phase I. ORISE was chosen because they had performed the Phase I tasks and summarized the corresponding survey data therefrom

  9. Annular lupus vulgaris: an unusual case undiagnosed for five years.

    Science.gov (United States)

    Gönül, Müzeyyen; Kiliç, Arzu; Külcü Cakmak, Seray; Gül, Ulker; Koçak, Oğuzhan; Demiriz, Murat

    2007-01-01

    Tuberculosis is still a serious problem in both developing and developed countries. It is often confused with various cutaneous disorders both clinically and histopathologically.A 46-year-old woman attended our clinic with progressive, asymptomatic, annular skin lesions on her right upper extremity for 5 years. She had received many different therapies for these lesions at other institutions previously but these medications were not effective and the lesions deteriorated. On dermatological examination, well-demarcated, irregular bordered, violaceous colored, elevated and crusted annular lesions on her right hand dorsum and forearm were observed. She was diagnosed as having lupus vulgaris clinically and histopathologically. Antituberculosis therapy was administered and regression of the lesions started in the second week of medication.We report a case of long-standing, undiagnosed and uncommon, annular form of lupus vulgaris. We want to stress that clinical and histopathological findings are still important for the diagnosis of cutaneous tuberculosis.

  10. Vibration Analysis of Annular Sector Plates under Different Boundary Conditions

    Directory of Open Access Journals (Sweden)

    Dongyan Shi

    2014-01-01

    Full Text Available An analytical framework is developed for the vibration analysis of annular sector plates with general elastic restraints along each edge of plates. Regardless of boundary conditions, the displacement solution is invariably expressed as a new form of trigonometric expansion with accelerated convergence. The expansion coefficients are treated as the generalized coordinates and determined using the Rayleigh-Ritz technique. This work allows a capability of modeling annular sector plates under a variety of boundary conditions and changing the boundary conditions as easily as modifying the material properties or dimensions of the plates. Of equal importance, the proposed approach is universally applicable to annular sector plates of any inclusion angles up to 2π. The reliability and accuracy of the current method are adequately validated through numerical examples.

  11. Fault Detection and Isolation in Centrifugal Pumps

    DEFF Research Database (Denmark)

    Kallesøe, Carsten

    Centrifugal pumps are used in a variety of different applications, such as water supply, wastewater, and different industrial applications. Some pump installations are crucial for the applications to work. Failures can lead to substantial economic losses and can influence the life of many people...... is placed. The topic of this work is Fault Detection and Identification in centrifugal pumps. Different approaches are developed with special focus on robustness. Robustness with respect to disturbances, unknown parts of the system, and parameter variations are considered. All developed algorithms...... are tested on an industrial test setup, showing the usability of the algorithms on a real centrifugal pump....

  12. Gas dynamics in strong centrifugal fields

    Energy Technology Data Exchange (ETDEWEB)

    Bogovalov, S.V.; Kislov, V.A.; Tronin, I.V. [National research nuclear university “MEPhI”, Kashirskoje shosse, 31,115409, Moscow (Russian Federation)

    2015-03-10

    Dynamics of waves generated by scopes in gas centrifuges (GC) for isotope separation is considered. The centrifugal acceleration in the GC reaches values of the order of 106g. The centrifugal and Coriolis forces modify essentially the conventional sound waves. Three families of the waves with different polarisation and dispersion exist in these conditions. Dynamics of the flow in the model GC Iguasu is investigated numerically. Comparison of the results of the numerical modelling of the wave dynamics with the analytical predictions is performed. New phenomena of the resonances in the GC is found. The resonances occur for the waves polarized along the rotational axis having the smallest dumping due to the viscosity.

  13. Characterization of 40 mm dia centrifugal extractor by hydrodynamic and mass transfer experiments. Contributed Paper ED-03

    International Nuclear Information System (INIS)

    Centrifugal extractor is the candid candidate for Fast breeder reprocessing plant due to its low holdup, short contact time and compact size. In this work, 40 mm dia centrifugal extractor was characterized by hydrodynamic and mass transfer experiments. In hydrodynamic experiment, flooding curve was generated by conducting non-mass transfer experiment at different O/A ratio (from 0.06 to 11.5) at constant rotating speed (3000 rpm). Flooding curve indicated varying of throughput from 90 to 60 L/h. Holdup inside the rotating bowl and annular region were measured and liquid residence time in annular region was varying between 5 to 18 seconds depending upon the total throughput. In extraction experiment, mass transfer performance of given CE bowl was studied for different throughputs (from 6 to 60 L/h) at constant speed (3000 rpm) and at constant O/A ratio of one and results shows its overall mass transfer efficiency was nearly 99% for above throughput conditions. (author)

  14. Modeling of Centrifugal Force Field and the Effect on Filling and Solidification in Centrifugal Casting

    Science.gov (United States)

    Sheng, Wenbin; Ma, Chunxue; Gu, Wanli

    2011-06-01

    Based on the steady flow in a tube, a mathematical model has been established for the consideration of centrifuging force field by combining the equations of continuity, conservation of momentum and general energy. Effects of centrifugal field on the filling and solidification are modeled by two accessional terms: centrifugal force and Chorios force. In addition, the transfer of heat by convection is considered to achieve a coupling calculation of velocity field and temperature field. The solution of pressure item is avoided by introducing the stream function ψ(x,y) and the eddy function ξ(x,y). Corresponding difference formats for the simultaneous equations of centrifugal filling, the accessional terms and the solidifying latent heat have been established by the finite difference technique. Furthermore, the centrifugal filling and solidification processes in a horizontal tube are summarized to interpret the mechanism by which internal defects are formed in centrifugal castings.

  15. Mathematical Model of Combustion in Blunt Annular Ceramic Burner

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The computer simulation of the combustion process in blast furnace (BF) stove has been studied by using the k-ε-g turbulent diffusion flame model. The combustion process in blunt annular ceramic burner was calculated by using the software. The profiles of gas and air velocity, temperature of the combustion products, concentration of the components, and the shape and length of the flame during combustion have been researched . Compared with the original annular ceramic burner, the new design of the blunt one improves the mixing of the gas and the air significantly, and shortened the length of the flame.

  16. Mitral-aortic annular enlargement: modification of Manouguian's technique

    Directory of Open Access Journals (Sweden)

    Costa Mario Gesteira

    2002-01-01

    Full Text Available We hereby present a technical modification for mitral-aortic annular enlargement. The mitral valve is replaced through the retro-septal approach, avoiding patches for left atrial roof closure. We report a mitral-aortic valve replacement in a patient whose original annuli would preclude adequate prostheses. The simultaneous annular enlargement may be necessary for avoiding patient-prosthesis mismatch and for reconstructing destroyed mitral and aortic annuli. The technique may minimize the risk of bleeding and of paravalvular leakage, using an approach well known to cardiac surgeons.

  17. Portal annular pancreas: the pancreatic duct ring sign on MRCP.

    Science.gov (United States)

    Lath, Chinar O; Agrawal, Dilpesh S; Timins, Michael E; Wein, Melissa M

    2015-12-01

    Portal annular pancreas is a rare pancreatic variant in which the uncinate process of the pancreas extends and fuses to the dorsal surface of the body of the pancreas by surrounding the portal vein. It is asymptomatic, but it can be mistaken for a pancreatic head mass on imaging and could also have serious consequences during pancreatic surgery, if unrecognized. We report this case of a 53-year-old female patient who was diagnosed to have portal annular pancreas on the basis of an unusual course (ring appearance) of the main pancreatic duct on magnetic resonance cholangiopancreatography, not described earlier in the radiology literature. PMID:26649117

  18. Portal annular pancreas: the pancreatic duct ring sign on MRCP

    Directory of Open Access Journals (Sweden)

    Chinar O. Lath, MD

    2015-12-01

    Full Text Available Portal annular pancreas is a rare pancreatic variant in which the uncinate process of the pancreas extends and fuses to the dorsal surface of the body of the pancreas by surrounding the portal vein. It is asymptomatic, but it can be mistaken for a pancreatic head mass on imaging and could also have serious consequences during pancreatic surgery, if unrecognized. We report this case of a 53-year-old female patient who was diagnosed to have portal annular pancreas on the basis of an unusual course (ring appearance of the main pancreatic duct on magnetic resonance cholangiopancreatography, not described earlier in the radiology literature.

  19. Flow Visualisation of Annular Liquid Sheet Instability & Atomisation

    CERN Document Server

    Duke, Daniel; Soria, Julio

    2012-01-01

    Fluid dynamics videos of unstable thin annular liquid sheets are presented in this short paper. These videos are to be presented in the Gallery of Fluid Motion for the American Physical Society 65th Annual Meeting of the Division of Fluid Dynamics in San Diego, CA, 18-20 November 2012. An annular sheet of thickness h=1mm and mean radius R=18.9mm is subjected to aerodynamic axial shear from co-flowing air at various shear rates on both the inner and outer surface at a liquid sheet Reynolds Number of Re=500.

  20. Patch Type Granuloma Annulare Imitating Cutaneous T-Cell Lymphoma

    Directory of Open Access Journals (Sweden)

    Seval Doğruk Kaçar

    2015-03-01

    Full Text Available Granuloma annulare (GA is a benign inflammatory skin disease with distinct clinical and histopathological findings. Patch type GA is described with erythematous patches beyond the classical clinical appearance and an interstitial pattern is observed without histopathologically granulomas with disseminated histiocytes among collagen bundles and vessels. Here we report 46 year old woman diagnosed as patch type GA after a punch biopsy performed from the annular bordered patches in belly area, which is a classical area for mycosis fungoides (MF evolution, and lesions increasingly spreading out within a 2 year period.

  1. Counteracting ammonia inhibition in anaerobic digestion by removal with a hollow fiber membrane contactor.

    Science.gov (United States)

    Lauterböck, B; Ortner, M; Haider, R; Fuchs, W

    2012-10-01

    The aim of the current study was to investigate the feasibility of membrane contactors for continuous ammonia (NH₃-N) removal in an anaerobic digestion process and to counteract ammonia inhibition. Two laboratory anaerobic digesters were fed slaughterhouse wastes with ammonium (NH₄⁺) concentrations ranging from 6 to 7.4 g/L. One reactor was used as reference reactor without any ammonia removal. In the second reactor, a hollow fiber membrane contactor module was used for continuous ammonia removal. The hollow fiber membranes were directly submerged into the digestate of the anaerobic reactor. Sulfuric acid was circulated in the lumen as an adsorbent solution. Using this set up, the NH₄⁺-N concentration in the membrane reactor was significantly reduced. Moreover the extraction of ammonia lowered the pH by 0.2 units. In combination that led to a lowering of the free NH₃-N concentration by about 70%. Ammonia inhibition in the reference reactor was observed when the concentration exceeded 6 g/L NH₄⁺-N or 1-1.2 g/L NH₃-N. In contrast, in the membrane reactor the volatile fatty acid concentration, an indicator for process stability, was much lower and a higher gas yield and better degradation was observed. The chosen approach offers an appealing technology to remove ammonia directly from media having high concentrations of solids and it can help to improve process efficiency in anaerobic digestion of ammonia rich substrates.

  2. Emergency membrane contactor based absorption system for ammonia leaks in water treatment plants

    Institute of Scientific and Technical Information of China (English)

    SHAO Jiahui; FANG Xuliang; HE Yiliang; JIN Qiang

    2008-01-01

    Because of the suspected health risks of trihalomethanes (THMs), more and more water treatment plants have replaced traditionalchlorine disinfection process with chloramines but often without the proper absorption system installed in the case of ammonia leaksin the storage room. A pilot plant membrane absorption system was developed and installed in a water treatment plant for this purpose.Experimentally determined contact angle, surface tension, and corrosion tests indicated that the sulfuric acid was the proper choice as the absorbent for leaking ammonia using polypropylene hollow fiber membrane contactor. Effects of several operating conditionson the mass transfer coefficient, ammonia absorption, and removal efficiency were examined, including the liquid concentration,liquid velocity, and feed gas concentration. Under the operation conditions investigated, the gas absorption efficiency over 99.9%was achieved. This indicated that the designed pilot plant membrane absorption system was effective to absorb the leaking ammonia in the model storage room. The removal rate of the ammonia in the model storage room was also experimentally and theoretically foundto be primarily determined by the ammonia suction flow rate from the ammonia storage room to the membrane contactor. The ammoniaremoval rate of 99.9% was expected to be achieved within 1.3 h at the ammonia gas flow rate of 500 m3/h. The success of the pilot plantmembrane absorption system developed in this study illustrated the potential of this technology for ammonia leaks in water treatmentplant, also paved the way towards a larger scale application.

  3. A study of the operational effectiveness of a disk-rotor contactor in a deasphalting installation

    Energy Technology Data Exchange (ETDEWEB)

    Kvetkov, B.A.; Anisimkov, Yu.P.; Boreysha, T.Yu.; Bronfin, I.B.; Chernyshov, S.D.; Golygin, M.I.; Mikita, V.P.; Shkolnikov, V.M.; Veselovskaya, L.F.

    1980-01-01

    Results are cited of many years of operation and study of an industrial rotary disk contactor (RDK) in the process of deasphalting of Western Siberian oils. The evaluation of the operational effectiveness of the rotary disk contactor was conducted from the output of the deparaffinated oil with a viscosity index (IV) of 90. The asphalt processed had a conditional viscosity at 80 degrees C of 22 to 28 seconds, a boil away at 500 degrees C of 15 to 20 percent, a potential content of oils with a viscosity index of 90 of 30 percent. The operational effectiveness of the apparatus was studied with the following parameters: diameter of the rotary disks of 1.8 and 1.5 meters; rotor rotation speed of 0.8; 16 and 24 revolutions per minute; a raw material productivity of 22 to 34 cubic meters per hour; a top temperature of 80 to 85 degrees C; a temperature gradient of 25 to 27 degrees and a propane to raw material ratio of 3.3 to 4.5 total.

  4. Determination of economically justified parameters of synchronous disconnection at low-voltage circuit switching via a synchronous vacuum contactor

    Directory of Open Access Journals (Sweden)

    A.V. Verkhola

    2014-04-01

    Full Text Available Dependence of a single switching procedure cost upon the contact opening delay time and delay-time spread is derived for a low-voltage synchronous vacuum contactor. For different cost levels, boundaries of permissible values of delay-time and delay-time spread are specified.

  5. Talking about the Maintenance of AC Contactor%浅谈交流接触器的维修

    Institute of Scientific and Technical Information of China (English)

    王如军

    2011-01-01

    AC eleOromagnetic contactor as an automatic switch in the control of electrical equipment companies have been widely used. But for various reasons often lead to the emergence of various AC contactor failure or damage. Therefore, there must be targeted to take various measures to do a goodjob AC contactor failure prevention, maintenance and processing, to protect AC contactor to work.%交流接触器作为一种电磁式自动开关在企业电气设备的控制中得到了广泛的应用。但由于各种原因经常导致交流接触器出现各种故障甚至损坏。因此,必须有针对性地采取各种措施,认真做好交流接触器故障的预防、维护和处理工作,保障交流接触器正常工作。

  6. INACTIVATION OF CRYPTOSPORIDIUM OOCYSTS IN A PILOT-SCALE OZONE BUBBLE-DIFFUSER CONTACTOR - II: MODEL VALIDATION AND APPLICATION

    Science.gov (United States)

    The ADR model developed in Part I of this study was successfully validated with experimenta data obtained for the inactivation of C. parvum and C. muris oocysts with a pilot-scale ozone-bubble diffuser contactor operated with treated Ohio River water. Kinetic parameters, required...

  7. FLOW REGIMES, GAS HOLD-UP AND AXIAL GAS MIXING IN THE GAS-LIQUID MULTISTAGE AGITATED CONTACTOR

    NARCIS (Netherlands)

    BREMAN, BB; BEENACKERS, AACM; BOUMA, MJ

    1995-01-01

    Experimental data are reported on Row regimes, gas hold-up and axial gas mixing of a gas-liquid Multi-stage Agitated Contactor (MAC), consisting of nine compartments [height, H, over diameter, D = 1; D = 0.09 m) separated by horizontal baffles with an opening of 0.04 m and with one centrally positio

  8. Membrane contactor/separator for an advanced ozone membrane reactor for treatment of recalcitrant organic pollutants in water

    International Nuclear Information System (INIS)

    An advanced ozone membrane reactor that synergistically combines membrane distributor for ozone gas, membrane contactor for pollutant adsorption and reaction, and membrane separator for clean water production is described. The membrane reactor represents an order of magnitude improvement over traditional semibatch reactor design and is capable of complete conversion of recalcitrant endocrine disrupting compounds (EDCs) in water at less than three minutes residence time. Coating the membrane contactor with alumina and hydrotalcite (Mg/Al=3) adsorbs and traps the organics in the reaction zone resulting in 30% increase of total organic carbon (TOC) removal. Large surface area coating that diffuses surface charges from adsorbed polar organic molecules is preferred as it reduces membrane polarization that is detrimental to separation. - Graphical abstract: Advanced ozone membrane reactor synergistically combines membrane distributor for ozone, membrane contactor for sorption and reaction and membrane separator for clean water production to achieve an order of magnitude enhancement in treatment performance compared to traditional ozone reactor. Highlights: ► Novel reactor using membranes for ozone distributor, reaction contactor and water separator. ► Designed to achieve an order of magnitude enhancement over traditional reactor. ► Al2O3 and hydrotalcite coatings capture and trap pollutants giving additional 30% TOC removal. ► High surface area coating prevents polarization and improves membrane separation and life.

  9. Molecular structure and centrifugal distortion in methylthioethyne

    NARCIS (Netherlands)

    Engelsen, D. den

    1969-01-01

    The investigation of the microwave spectra of five isotopic species of methylthioethyne, HCCSCH3 enabled a fairly reliable calculation to be made of bond lengths and angles. The centrifugal distortion parameters are related to molecular vibrations.

  10. Multi-point optimization of recirculation flow type casing treatment in centrifugal compressors

    Science.gov (United States)

    Tun, Min Thaw; Sakaguchi, Daisaku

    2016-06-01

    High-pressure ratio and wide operating range are highly required for a turbocharger in diesel engines. A recirculation flow type casing treatment is effective for flow range enhancement of centrifugal compressors. Two ring grooves on a suction pipe and a shroud casing wall are connected by means of an annular passage and stable recirculation flow is formed at small flow rates from the downstream groove toward the upstream groove through the annular bypass. The shape of baseline recirculation flow type casing is modified and optimized by using a multi-point optimization code with a metamodel assisted evolutionary algorithm embedding a commercial CFD code CFX from ANSYS. The numerical optimization results give the optimized design of casing with improving adiabatic efficiency in wide operating flow rate range. Sensitivity analysis of design parameters as a function of efficiency has been performed. It is found that the optimized casing design provides optimized recirculation flow rate, in which an increment of entropy rise is minimized at grooves and passages of the rotating impeller.

  11. Geotechnical Centrifuge Studies of Unsaturated Transport

    Science.gov (United States)

    Smith, R. W.; Mattson, E. D.; Palmer, C. D.

    2007-12-01

    Improved understanding of contaminant migration in heterogeneous, variably saturated porous media is required to better define the long-term stewardship requirements for U.S. Department of Energy (DOE) lands and to assist in the design of effective vadose-zone barriers to contaminant migrations. A geotechnical centrifuge provides an experimental approach to explore vadose zone transport over a wide range of relevant conditions in time frames not possible for conventional bench-top experiments. Our research to date resulted in the design, construction, and testing of in-flight experimental apparatus allowing the replication of traditional bench top unsaturated transport experiments using the 2-meter radius geotechnical centrifuge capabilities at the Idaho National Laboratory. Additionally we conducted a series of unsaturated 1-dimenstional column experiments using conservative tracers to evaluate the effects of increased centrifugal acceleration on derived transport properties and assessing the scaling relationships for these properties. Our experimental results indicated that breakthrough times for a conservative tracer decreased significantly and systematically as a function of increased centrifugal acceleration. Differences between these experimental results and estimates based on predictive scaling rules are due to slight moisture content differences between experiments at different centrifugal accelerations. In contrast, dispersion coefficients varied systemically with centrifugal acceleration in accordance with predictive scaling rules. The results we obtained in this study indicate that the centrifuge technique is a viable experimental method for the study of subsurface processes where gravitational acceleration is important. The geotechnical centrifuge allows experiments to be completed more quickly than tests conducted at 1-gravity and can be used to experimentally address important scaling issues, and permits experiments under a range of conditions that

  12. Towards Centrifugal Compressor Stages Virtual Testing

    OpenAIRE

    Guidotti, Emanuele

    2014-01-01

    Flow features inside centrifugal compressor stages are very complicated to simulate with numerical tools due to the highly complex geometry and varying gas conditions all across the machine. For this reason, a big effort is currently being made to increase the fidelity of the numerical models during the design and validation phases. Computational Fluid Dynamics (CFD) plays an increasing role in the assessment of the performance prediction of centrifugal compressor stages. Historically, CFD wa...

  13. Meridional Considerations of the Centrifugal Compressor Development

    OpenAIRE

    Xu, C.; Amano, R. S.

    2012-01-01

    Centrifugal compressor developments are interested in using optimization procedures that enable compressor high efficiency and wide operating ranges. Recently, high pressure ratio and efficiency of the centrifugal compressors require impeller design to pay attention to both the blade angle distribution and the meridional profile. The geometry of the blades and the meridional profile are very important contributions of compressor performance and structure reliability. This paper presents some ...

  14. Finite element analysis of centrifugal impellers

    OpenAIRE

    Sham Sunder, K.

    1981-01-01

    A three-dimensional method of stress analysis using finite element techniques is presented for determining the stress distribution in centrifugal impellers. It can treat all of the three types of loading possible in an inpeller, viz centrifugal, thermal and fluid. The method has no known limitations with regards to the geometric factors such as asymnetry of disk, blade curvature, presence of a cover disk or shroud, single or double sided impeller etc. A comparison of r...

  15. CFD Analysis of Centrifugal Pump: A Review

    OpenAIRE

    Narayan P. Jaiswal

    2014-01-01

    The main objective of this work is to understand role of the computational fluid dynamics (CFD) technique in analyzing and predicting the performance of centrifugal pump. Computational Fluid Dynamics (CFD) is the present day state-of-art technique for fluid flow analysis. The critical review of CFD analysis of CFD analysis of centrifugal pump along with future scope for further improvement is presented in this paper. Different solver like ANSYS-CFX, FLUENT etc can be used for ...

  16. Enrichment technology. Dependable vendor of gas centrifuges

    International Nuclear Information System (INIS)

    Enrichment Technology is an innovative, high-tech company that develops, manufactures and installs gas centrifuges for enriching uranium. In addition, Enrichment Technology designs enrichment plants that use gas centrifuge technology. This technology offers the most efficient and cost-effective method for enriching uranium yet: high-performance, safe technology that dominates the market with a global share of 45 percent. A determining factor in Enrichment Technology's success is its mission: supplying its customers with safe, reliable technology. Production of the centrifuges requires versatile know-how and collaboration between different departments as well as interdisciplinary teams at the various sites. More than 2000 operators at 8 sites in 5 countries contribute their individual knowledge and personal skills in order to produce this exceptional technology. The head office is in Beaconsfield near London and the operational headquarters are in Almelo in the Netherlands. There are other sites in Germany (Juelich und Gronau), Great Britain (Capenhurst) as well as project sites in the USA and France. Capenhurst is where experienced engineers design new enrichment plants and organise their construction. Centrifuge components are manufactured in Almelo and Juelich, while the pipework needed to connect up the centrifuges is produced at the site in Gronau. In Juelich, highly qualified scientists in interdisciplinary teams are continuously researching ways of improving the current centrifuges. Communication between specialists in the fields of chemistry, physics and engineering forms the basis for the company's success and the key to extending this leading position in the global enrichment market. (orig.)

  17. Separation of uranium isotopes by gas centrifugation

    International Nuclear Information System (INIS)

    The uranium isotope enrichment is studied by means of the countercurrent gas centrifuge driven by thermal convection. A description is given of (a) the transfer and purification of the uranium hexafluoride used as process gas in the present investigation; (b) the countercurrent centrifuge ZG3; (c) the system designed for the introduction and extraction of the process gas from the centrifuge; (d) the measurement of the process gas flow rate through the centrifuge; (e) the determination of the uranium isotopic abundance by mass spectrometry; (f) the operation and mechanical behavior of the centrifuge and (g) the isotope separation experiments, performed, respectively, at total reflux and with production of enriched material. The results from the separation experiments at total reflux are discussed in terms of the enrichment factor variation with the magnitude and flow profile of the countercurrent given by the temperature difference between the rotor covers. As far as the separation experiments with production are concerned, the discussion of their results is presented through the variation of the enrichment factor as a function of the flow rate, the observed asymmetry of the process and the calculated separative power of the centrifuge. (Author)

  18. Clinical experience with the Sarns centrifugal pump.

    Science.gov (United States)

    Curtis, J J; Walls, J T; Demmy, T L; Boley, T M; Schmaltz, R A; Goss, C F; Wagner-Mann, C C

    1993-07-01

    Since October 1986, we have had experience with 96 Sarns centrifugal pumps in 72 patients (pts). Heparinless left atrial to femoral artery or aorta bypass was used in 14 pts undergoing surgery on the thoracic aorta with 13 survivors (93%). No paraplegia or device-related complications were observed. In 57 patients, the Sarns centrifugal pump was used as a univentricular (27 pts) or biventricular (30 pts) cardiac assist device for postcardiotomy cardiogenic shock. In these patients, cardiac assist duration ranged from 2 to 434 h with a hospital survival rate of 29% in those requiring left ventricular assist and 13% in those requiring biventricular assist. Although complications were ubiquitous in this mortally ill patient population, in 5,235 pump-hours, no pump thrombosis was observed. Hospital survivors followed for 4 months to 6 years have enjoyed an improved functional class. We conclude that the Sarns centrifugal pump is an effective cardiac assist device when used to salvage patients otherwise unweanable from cardiopulmonary bypass. Partial left ventricular bypass using a centrifugal pump has become our procedure of choice for unloading the left ventricle and for maintenance of distal aortic perfusion pressure when performing surgery on the thoracic aorta. This clinical experience with the Sarns centrifugal pump appears to be similar to that reported with other centrifugal assist devices.

  19. Current-voltage characteristics of a cathodic plasma contactor with discharge chamber for application in electrodynamic tether propulsion

    Science.gov (United States)

    Xie, Kan; Martinez, Rafael A.; Williams, John D.

    2014-04-01

    This paper focuses on the net electron-emission current as a function of bias voltage of a plasma source that is being used as the cathodic element in a bare electrodynamic tether system. An analysis is made that enables an understanding of the basic issues determining the current-voltage (C-V) behaviour. This is important for the efficiency of the electrodynamic tether and for low impedance performance without relying on the properties of space plasma for varying orbital altitudes, inclinations, day-night cycles or the position of the plasma contactor relative to the wake of the spacecraft. The cathodic plasma contactor considered has a cylindrical discharge chamber (10 cm in diameter and ˜11 cm in length) and is driven by a hollow cathode. Experiments and a 1D spherical model are both used to study the contactor's C-V curves. The experiments demonstrate how the cathodic contactor would emit electrons into space for anode voltages in the range of 25-40 V, discharge currents in the range of 1-2.5 A, and low xenon gas flows of 2-4 sccm. Plasma properties are measured and compared with (3 A) and without net electron emission. A study of the dependence of relevant parameters found that the C-V behaviour strongly depends on electron temperature, initial ion energy and ion emission current at the contactor exit. However, it depended only weakly on ambient plasma density. The error in the developed model compared with the experimental C-V curves is within 5% at low electron-emission currents (0-2 A). The external ionization processes and high ion production rate caused by the discharge chamber, which dominate the C-V behaviour at electron-emission currents over 2 A, are further highlighted and discussed.

  20. Design and evaluation of hydraulic baffled-channel PAC contactor for taste and odor removal from drinking water supplies.

    Science.gov (United States)

    Kim, Young-Il; Bae, Byung-Uk

    2007-05-01

    Based on the concept of hydraulic flocculator, a baffled-channel powdered activated carbon (PAC) contactor, placed before the rapid-mixing basin, was designed and evaluated for removal of taste and odor (T&O) in drinking water. PAC adsorption kinetic tests for raw water samples were conducted for selection of design parameters related to contact time and degree of mixing. Within the tested range of velocity gradient (G) from 18 to 83s(-1), mixing had a relatively minor effect on the adsorption kinetics of the PAC. The hydrodynamic characteristics of the pilot-scale horizontally and vertically baffled-channel PAC contactor were investigated by tracer tests. It was found that the plug flow fractions of vertically baffled-channel PAC contactor (vBPC) were higher than those of the horizontally baffled-channel PAC contactor (hBPC) for the same bend width or bend height. However, the hBPC seems to be more appropriate than the vBPC in terms of construction and maintenance. The geosmin and MIB removal rate increased with the number of baffles, PAC dose and contact time increased regardless of bend width in the pilot-scale hBPC. The pair of full-scale hBPCs at Pohang water treatment plant, having a design capacity of 6.5x10(4)m(3)/d with 20min of hydraulic retention time with a safety factor of 2, was designed based on lab- and pilot-scale experimental results. Under a velocity gradient of 20s(-1), the number of baffles to be installed was calculated to be 20 with a space of about 2m between each baffle, resulting in a hydraulic head loss through the contactor of about 0.056m. The successful application of hBPC for T&O removal from drinking water supplies should provide momentum for developing more effective treatment methods.

  1. Design curves for circular and annular duct silencers

    Science.gov (United States)

    Watson, Willie R.; Ramakrishnan, R.

    1989-01-01

    Conventional models of sound propagation between porous walls (Scott, 1946) are adapted in order to calculate design curves for the lined circular and annular-duct silencers used in HVAC systems. The derivation of the governing equations is outlined, and results for two typical cases are presented graphically. Good agreement with published experimental data is demonstrated.

  2. Improvement of image processing algorithms for annular flow

    International Nuclear Information System (INIS)

    Annular flow occurs in a wide range of industrial heat-transfer equipment, including the top of a BWR core, in the steam generator of a PWR, and in postulated accident scenarios including critical heat flux (CHF) by dryout. The modeling of annular flow often requires information regarding the average thickness of liquid film at the periphery of the flow channel as a measurement of film roughness (film roughness concept). More recently, two-region modeling efforts require wave intermittency as a measurement of disturbance wave (as opposed to base film thickness) contribution to gas-to-liquid momentum transfer and pressure loss. The present work focuses on the characterization of film behaviors in annular flow using quantitative visualization. The data reduction codes for planar laser-induced flourescence (PLIF) imaging and back-lit quartz tube imaging have been further developed to improve measurement accuracy. Film thickness distribution (base film and wave), disturbance wave length, and wave intermittency estimates have been updated and applied to a recent two-region annular flow model. Outputs of average film thickness, pressure gradient, and average wave velocity have been modeled with mean absolute errors of 8.70%, 17.42%, and 19.14%, respectively. (author)

  3. Flow of viscoplastic fluids in eccentric annular geometries

    DEFF Research Database (Denmark)

    Szabo, Peter; Hassager, Ole

    1992-01-01

    A classification of flowfields for the flow of a Bingham fluid in general eccentric annular geometries is presented. Simple arguments show that a singularity can exist in the stress gradient on boundaries between zones with yielded and un-yielded fluid respectively. A Finite Element code is used ...

  4. Numerical and experimental investigation of the centrifugal stage axial compressor centrifugal stationary GTE

    OpenAIRE

    Шаровский, Михаил Антонович; Усатенко, Елена Александровна; Шелковский, Михаил Юрьевич; Зубрицкая, Инна Аркадьевна

    2012-01-01

    About increase in efficiency of a centrifugal step of the compressor in low-dimensional GTD with the osetsentrobezhny compressor. Use of the “closed” driving wheel as basic possibility of receiving a highly effective centrifugal step. The gazodinamichesky aspect of its design and manufacturing is considered.

  5. Centrifugal acceleration in the magnetotail lobes

    Directory of Open Access Journals (Sweden)

    H. Nilsson

    2010-02-01

    Full Text Available Combined Cluster EFW and EDI measurements have shown that cold ion outflow in the magnetospheric lobes dominates the hydrogen ion outflow from the Earth's atmosphere. The ions have too low kinetic energy to be measurable with particle instruments, at least for the typical spacecraft potential of a sunlit spacecraft in the tenuous lobe plasmas outside a few RE. The measurement technique yields both density and bulk velocity, which can be combined with magnetic field measurements to estimate the centrifugal acceleration experienced by these particles. We present a quantitative estimate of the centrifugal acceleration, and the velocity change with distance which we would expect due to centrifugal acceleration. It is found that the centrifugal acceleration is on average outward with an average value of about of 5 m s−2. This is small, but acting during long transport times and over long distances the cumulative effect is significant, while still consistent with the relatively low velocities estimated using the combination of EFW and EDI data. The centrifugal acceleration should accelerate any oxygen ions in the lobes to energies observable by particle spectrometers. The data set also put constraints on the effectiveness of any other acceleration mechanisms acting in the lobes, where the total velocity increase between 5 and 19 RE geocentric distance is less than 5 km s−1.

  6. A Review of Biomedical Centrifugal Microfluidic Platforms

    Directory of Open Access Journals (Sweden)

    Minghui Tang

    2016-02-01

    Full Text Available Centrifugal microfluidic or lab-on-a-disc platforms have many advantages over other microfluidic systems. These advantages include a minimal amount of instrumentation, the efficient removal of any disturbing bubbles or residual volumes, and inherently available density-based sample transportation and separation. Centrifugal microfluidic devices applied to biomedical analysis and point-of-care diagnostics have been extensively promoted recently. This paper presents an up-to-date overview of these devices. The development of biomedical centrifugal microfluidic platforms essentially covers two categories: (i unit operations that perform specific functionalities, and (ii systems that aim to address certain biomedical applications. With the aim to provide a comprehensive representation of current development in this field, this review summarizes progress in both categories. The advanced unit operations implemented for biological processing include mixing, valving, switching, metering and sequential loading. Depending on the type of sample to be used in the system, biomedical applications are classified into four groups: nucleic acid analysis, blood analysis, immunoassays, and other biomedical applications. Our overview of advanced unit operations also includes the basic concepts and mechanisms involved in centrifugal microfluidics, while on the other hand an outline on reported applications clarifies how an assembly of unit operations enables efficient implementation of various types of complex assays. Lastly, challenges and potential for future development of biomedical centrifugal microfluidic devices are discussed.

  7. Bacterial Cellulose Production by Gluconacetobacter sp. RKY5 in a Rotary Biofilm Contactor

    Science.gov (United States)

    Kim, Yong-Jun; Kim, Jin-Nam; Wee, Young-Jung; Park, Don-Hee; Ryu, Hwa-Won

    A rotary biofilm contactor (RBC) inoculated with Gluconacetobacter sp. RKY5 was used as a bioreactor for improved bacterial cellulose production. The optimal number of disk for bacterial cellulose production was found to be eight, at which bacterial cellulose and cell concentrations were 5.52 and 4.98 g/L. When the aeration rate was maintained at 1.25 vvm, bacterial cellulose and cell concentrations were maximized (5.67 and 5.25 g/L, respectively). The optimal rotation speed of impeller in RBC was 15 rpm. When the culture pH in RBC was not controlled during fermentation, the maximal amount of bacterial cellulose (5.53 g/L) and cells (4.91 g/L) was obtained. Under the optimized culture conditions, bacterial cellulose and cell concentrations in RBC reached to 6.17 and 5.58 g/L, respectively.

  8. Bioaugmentation for treating transient 4-fluorocinnamic acid shock loads in a rotating biological contactor.

    Science.gov (United States)

    Amorim, Catarina L; Duque, Anouk F; Afonso, Carlos M M; Castro, Paula M L

    2013-09-01

    A rotating biological contactor (RBC) was used to treat shock loadings of 4-fluorocinnamic acid (4-FCA). Intermittent 4-FCA shocks of 35 mg L(-1) were applied (ca. 3 months) with only limited mineralization occurring and accumulation of 4-fluorobenzoate (4-FBA) as an intermediate. After bioaugmentation with a degrading bacterium the RBC was able to deal with 4-FCA intermittent loading of 80 mg L(-1) however, a gradual decline in RBC performance occurred, leading to 4-FBA accumulation. The degrading strain was recovered from the biofilm during 2 months but intermittent feeding may have led to diminishing strain numbers. Distinct bacterial communities in the 1st and the 5th and 10th stages of the RBC were revealed by denaturating gradient gel electrophoresis. Several isolates retrieved from the RBC transformed 4-FCA into 4-FBA but only two strains mineralized the compound. Bioaugmentation allowed removal of the fluorinated compound however intermittent feeding may have compromised the bioreactor efficiency.

  9. Recovery of volatile fatty acids via membrane contactor using flat membranes: experimental and theoretical analysis.

    Science.gov (United States)

    Tugtas, Adile Evren

    2014-07-01

    Volatile fatty acid (VFA) separation from synthetic VFA solutions and leachate was investigated via the use of a membrane contactor. NaOH was used as a stripping solution to provide constant concentration gradient of VFAs in both sides of a membrane. Mass flux (12.23 g/m(2)h) and selectivity (1.599) observed for acetic acid were significantly higher than those reported in the literature and were observed at feed pH of 3.0, flow rate of 31.5 ± 0.9 mL/min, and stripping solution concentration of 1.0 N. This study revealed that the flow rate, stripping solution strength, and feed pH affect the mass transfer of VFAs through the PTFE membrane. Acetic and propionic acid separation performances observed in the present study provided a cost effective and environmental alternative due to elimination of the use of extractants.

  10. Numerical Simulation and Analysis of CO2 Removal in a Polypropylene Hollow Fiber Membrane Contactor

    Directory of Open Access Journals (Sweden)

    Zhien Zhang

    2014-01-01

    Full Text Available This present study shows a comprehensive 2D numerical model for removal of CO2 in a polypropylene (PP hollow fiber membrane contactor (HFMC using the computational fluid dynamics (CFD method. Monoethanolamine (MEA solution was used as the liquid absorbent in a nonwetting mode. The simulation results represented that higher liquid velocity and concentration and lower gas velocity and concentration led to higher percent of CO2 removal. The most proper parameters for CO2 removal were less than 1 mol m−3 gas concentration and 0.2 m s−1 gas flow rate, and for MEA the values were above 8 mol m−3 concentration and approximately 1 m s−1 liquid velocity. Furthermore, the model was validated with the experiment results. Therefore, the modeling results provided references to the selection of absorbents and operation parameters in the experimental study and pilot-scale applications.

  11. The use of the fungus Dichomitus squalens for degradation in rotating biological contactor conditions.

    Science.gov (United States)

    Novotný, Ceněk; Trošt, Nina; Šlušla, Martin; Svobodová, Kateřina; Mikesková, Hana; Válková, Hana; Malachová, Kateřina; Pavko, Aleksander

    2012-06-01

    Biodegradation potential of Dichomitus squalens in biofilm cultures and rotating biological contactor (RBC) was investigated. The fungus formed thick biofilms on inert and lignocellulosic supports and exhibited stable activities of laccase and manganese peroxidase to reach 40-62 and 25-32% decolorization of anthraquinone Remazol Brilliant Blue R and heterocyclic phthalocyanine dyes, respectively. The decolorization ceased when glucose concentration dropped to 1 mmol l(-1). In RBC reactor, respective decolorizations of Remazol Brilliant Blue R and heterocyclic Methylene Blue and Azure B dyes (50 mg l(-1)) attained 99%, 93%, and 59% within 7, 40 and 200 h. The fungus exhibited tolerance to coliform and non-coliform bacteria on rich organic media, the inhibition occurred only on media containing tryptone and NaCl. The degradation efficiency in RBC reactor, capability to decolorize a wide range of dye structures and tolerance to bacterial stress make D. squalens an organism applicable to remediation of textile wastewaters.

  12. Open absorption system for cooling and air conditioning using membrane contactors. 2006 annual report

    Energy Technology Data Exchange (ETDEWEB)

    Conde-Petit, M. [M. Conde Engineering, Zuerich (Switzerland); Weber, R. [Materials Science and Technology (EMPA), Abteilung Bautechnologien, Duebendorf (Switzerland)

    2006-11-15

    This illustrated annual report for 2006 for the Swiss Federal Office of Energy (SFOE) reports on work being done on the development of an open absorption system for cooling and air-conditioning. The report reviews the construction of a first prototype and the manufacture of its components. The conceptual design of this new type of air handling unit (AHU), operating with a liquid desiccant, is discussed. The AHU is to be autonomous and the system will not require additional mechanical refrigeration. It is to be thermally driven at temperatures below 80 {sup o}C. Waste heat sources, solar collectors, district heating plants and co-generation systems are targeted as providers of thermal energy at this temperature level. Work carried out is reported on, including that on two-stream membrane contactors.

  13. Stability study and lyophilization of vitamin E-loaded nanocapsules prepared by membrane contactor.

    Science.gov (United States)

    Khayata, N; Abdelwahed, W; Chehna, M F; Charcosset, C; Fessi, H

    2012-12-15

    In this research, we studied the accelerated stability of vitamin E-loaded nanocapsules (NCs) prepared by the nanoprecipitation method. Vitamin E-loaded NCs were optimized firstly at the laboratory scale and then scaled up using the membrane contactor technique. The optimum conditions of the membrane contactor preparation (pilot scale) produced vitamin E-loaded NCs with an average size of 253 nm, polydispersity index 0.19 and a zeta potential -16 mV. The average size, polydispersity index and zeta potential values were 185 nm, 0.12 and -15 mV, respectively for the NCs prepared at laboratory scale. No significant changes were noticed in these values after 3 and 6 months of storage at high temperature (40±2 °C) and relative humidity (75±5%) in spite of vitamin E sensitivity to light, heat and oxygen. The entrapment efficiency of NCs prepared at pilot scale was 97% at the beginning of the stability study, and became (95%, 59%) after 3 and 6 months of storage, respectively. These values at lab-scale were (98%, 96%, and 89%) at time zero and after 3 and 6 months of storage, respectively. This confirms the ability of vitamin E encapsulation to preserve its stability, which is one major goal of our work. Lyophilization of the optimized formula at lab-scale was also performed. Four types of cryoprotectants were tested (poly(vinyl pyrrolidone), sucrose, mannitol, and glucose). Freeze-dried NCs prepared with sucrose were found acceptable. The other lyophilized NCs obtained at different conditions presented large aggregates.

  14. Centrifugal compressor design for electrically assisted boost

    Science.gov (United States)

    Y Yang, M.; Martinez-Botas, R. F.; Zhuge, W. L.; Qureshi, U.; Richards, B.

    2013-12-01

    Electrically assisted boost is a prominent method to solve the issues of transient lag in turbocharger and remains an optimized operation condition for a compressor due to decoupling from turbine. Usually a centrifugal compressor for gasoline engine boosting is operated at high rotational speed which is beyond the ability of an electric motor in market. In this paper a centrifugal compressor with rotational speed as 120k RPM and pressure ratio as 2.0 is specially developed for electrically assisted boost. A centrifugal compressor including the impeller, vaneless diffuser and the volute is designed by meanline method followed by 3D detailed design. Then CFD method is employed to predict as well as analyse the performance of the design compressor. The results show that the pressure ratio and efficiency at design point is 2.07 and 78% specifically.

  15. Analysis of Secondary Flows in Centrifugal Impellers

    Directory of Open Access Journals (Sweden)

    Brun Klaus

    2005-01-01

    Full Text Available Secondary flows are undesirable in centrifugal compressors as they are a direct cause for flow (head losses, create nonuniform meridional flow profiles, potentially induce flow separation/stall, and contribute to impeller flow slip; that is, secondary flows negatively affect the compressor performance. A model based on the vorticity equation for a rotating system was developed to determine the streamwise vorticity from the normal and binormal vorticity components (which are known from the meridional flow profile. Using the streamwise vorticity results and the small shear-large disturbance flow method, the onset, direction, and magnitude of circulatory secondary flows in a shrouded centrifugal impeller can be predicted. This model is also used to estimate head losses due to secondary flows in a centrifugal flow impeller. The described method can be employed early in the design process to develop impeller flow shapes that intrinsically reduce secondary flows rather than using disruptive elements such as splitter vanes to accomplish this task.

  16. Centrifugal compressor design for electrically assisted boost

    International Nuclear Information System (INIS)

    Electrically assisted boost is a prominent method to solve the issues of transient lag in turbocharger and remains an optimized operation condition for a compressor due to decoupling from turbine. Usually a centrifugal compressor for gasoline engine boosting is operated at high rotational speed which is beyond the ability of an electric motor in market. In this paper a centrifugal compressor with rotational speed as 120k RPM and pressure ratio as 2.0 is specially developed for electrically assisted boost. A centrifugal compressor including the impeller, vaneless diffuser and the volute is designed by meanline method followed by 3D detailed design. Then CFD method is employed to predict as well as analyse the performance of the design compressor. The results show that the pressure ratio and efficiency at design point is 2.07 and 78% specifically

  17. Comparison of extraction and stripping behavior of uranium in centrifugal contactors using tributyl phosphate (TBP) and N,N-dihexyl octanamide (DHOA) as extractants

    International Nuclear Information System (INIS)

    Uranium analysis in organic and aqueous phases was carried out by Davis Grey titration. The extraction and stripping behaviour of the the two solvents under the conditions used in this study are compared. As expected, uranium extraction increased with increased feed acidity for both the extractants. Stripping studies of uranium from loaded were carried out using distilled water. The stripping of uranium decreased with increased feed acidity (employed during extraction cycle). This behavior was explained in terms of acid reflux during the stripping cycle. These studies suggested that uranium extraction ability of DHOA at 3-4 M HNO3 as feed acidity, is comparable to that of TBP. However, stripping behavior is better than that of TBP. These observations were in conformity with the batch as well as counter-current mixer settler runs

  18. Demonstration of Caustic-Side Solvent Extraction with Optimized Solvent in the 2-cm Centrifugal Contactor Apparatus Using Dissolved Salt Cake from Tank 37H

    Energy Technology Data Exchange (ETDEWEB)

    Norato, M.A.

    2002-10-21

    A solvent extraction process for removal of cesium from alkaline solutions has been developed utilizing a novel solvent invented at the Oak Ridge National Laboratory (ORNL). This solvent consists of a calix[4]arene-crown-6 extractant (BOBCalix) dissolved in an inert hydrocarbon matrix (Isopar(R) L). An alkylphenoxy alcohol modifier added to the solvent enhances the extraction power of the calixarene and prevents the formation of a third phase. An additional additive, trioctylamine (TOA), improves stripping performance and mitigates the effects of any surfactants present in the feed stream. The solvent extraction process was successfully demonstrated with actual SRS HLW supernate during testing performed at SRTC in FY-2001. However, the solvent system has recently been optimized to enhance extractant solubility in the diluent and increase suppressor concentration. The results of the optimized solvent performance in tests using the same SRS composite waste supernate as was used FY-20 01 are described in another report.

  19. Demonstration of Caustic-Side Solvent Extraction with Optimized Solvent in the 2-cm Centrifugal Contactor Apparatus Using Dissolved Salt Cake from Tank 37H

    Energy Technology Data Exchange (ETDEWEB)

    Norato, M.A.

    2003-01-06

    Researchers successfully demonstrated the chemistry of the Caustic-Side Solvent Extraction (CSSX) flow sheet with optimized solvent. This represents the third such process demonstration using actual Savannah River Site (SRS) high level waste (HLW). The present test differed from previous studies in the use of radioactive waste derived from Tank 37H dissolved salt cake, as opposed to supernate solutions used in previous demonstrations.

  20. Wave-Driven Rotation In Centrifugal Mirrors

    International Nuclear Information System (INIS)

    Centrifugal mirrors use supersonic rotation to provide axial confinement and enhanced stability. Usually the rotation is produced using electrodes, but these electrodes have limited the rotation to the Alfven critical ionization velocity, which is too slow to be useful for fusion. Instead, the rotation could be produced using radio frequency waves. A fixed azimuthal ripple is a simple and efficient wave that could produce rotation by harnessing alpha particle energy. This is an extension of the alpha channeling effect. The alpha particle power and efficiency in a simulated devices is sufficient to produce rotation without external energy input. By eliminating the need for electrodes, this opens new opportunities for centrifugal traps.

  1. Detection methods for centrifugal microfluidic platforms.

    Science.gov (United States)

    Burger, Robert; Amato, Letizia; Boisen, Anja

    2016-02-15

    Centrifugal microfluidics has attracted much interest from academia as well as industry, since it potentially offers solutions for affordable, user-friendly and portable biosensing. A wide range of so-called fluidic unit operations, e.g. mixing, metering, liquid routing, and particle separation, have been developed and allow automation and integration of complex assay protocols in lab-on-a-disc systems. Besides liquid handling, the detection strategy for reading out the assay is crucial for developing a fully integrated system. In this review, we focus on biosensors and readout methods for the centrifugal microfluidics platform and cover optical as well as mechanical and electrical detection principles.

  2. Production of annular flat-topped vortex beams

    Institute of Scientific and Technical Information of China (English)

    Jiannong Chen; Yongjiang Yu; Feifei Wang

    2011-01-01

    @@ A model of an annular flat-topped vortex beam based on multi-Gaussian superimposition is proposed. We experimentally produce this beam with a computer-generated hologram (CGH) displayed on a spatial light modulator (SLM). The power of the beam is concentrated on a single-ring structure and has an extremely strong radial intensity gradient. This beam facilitates various applications ranging from Sisyphus atom cooling to micro-particle trapping.%A model of an annular fiat-topped vortex beam based on multi-Gaussian superimposition is proposed. We experimentally produce this beam with a computer-generated hologram (CGH) displayed on a spatial light modulator (SLM). The power of the beam is concentrated on a single-ring structure and has an extremely strong radial intensity gradient. This beam facilitates various applications ranging from Sisyphus atom cooling to micro-particle trapping.

  3. Energy and Exergy Analysis of an Annular Thermoelectric Heat Pump

    Science.gov (United States)

    Kaushik, S. C.; Manikandan, S.; Hans, Ranjana

    2016-07-01

    In this paper, the concept of an annular thermoelectric heat pump (ATEHP) has been introduced. An exoreversible thermodynamic model of the ATEHP considering the Thomson effect in conjunction with Peltier, Joule and Fourier heat conduction has been investigated using exergy analysis. New expressions for dimensionless heating power, optimum current at the maximum energy, exergy efficiency conditions and dimensionless irreversibilities in the ATEHP are derived. The results show that the heating power, energy and exergy efficiency of the ATEHP are lower than the flat-plate thermoelectric heat pump. The effects of annular shape parameter ( S r = r 2 /r 1), dimensionless temperature ratio ( θ = T h /T c) and the electrical contact resistances on the heating power, energy/exergy efficiency of an ATEHP have been studied. This study will help in the designing of actual ATEHP systems.

  4. Electroosmotic flow and Joule heating in preparative continuous annular electrochromatography.

    Science.gov (United States)

    Laskowski, René; Bart, Hans-Jörg

    2015-09-01

    An openFOAM "computational fluid dynamic" simulation model was developed for the description of local interaction of hydrodynamics and Joule heating in annular electrochromatography. A local decline of electrical conductivity of the background eluent is caused by an electrokinetic migration of ions resulting in higher Joule heat generation. The model equations consider the Navier-Stokes equation for incompressible fluids, the energy equation for stationary temperature fields, and the mass transfer equation for the electrokinetic flow. The simulations were embedded in commercial ANSYS Fluent software and in open-source environment openFOAM. The annular gap (1 mm width) contained an inorganic C8 reverse-phase monolith as stationary phase prepared by an in situ sol-gel process. The process temperature generated by Joule heating was determined by thermal camera system. The local hydrodynamics in the prototype was detected by a gravimetric contact-free measurement method and experimental and simulated values matched quite well. PMID:25997390

  5. Analysis of a Low-Angle Annular Expander Nozzle

    Directory of Open Access Journals (Sweden)

    Kyll Schomberg

    2015-01-01

    Full Text Available An experimental and numerical analysis of a low-angle annular expander nozzle is presented to observe the variance in shock structure within the flow field. A RANS-based axisymmetric numerical model was used to evaluate flow characteristics and the model validated using experimental pressure readings and schlieren images. Results were compared with an equivalent converging-diverging nozzle to determine the capability of the wake region in varying the effective area of a low-angle design. Comparison of schlieren images confirmed that shock closure occurred in the expander nozzle, prohibiting the wake region from affecting the area ratio. The findings show that a low angle of deflection is inherently unable to influence the effective area of an annular supersonic nozzle design.

  6. Wind generated rogue waves in an annular wave flume

    CERN Document Server

    Toffoli, A; Salman, H; Monbaliu, J; Frascoli, F; Dafilis, M; Stramignoni, E; Forza, R; Manfrin, M; Onorato, M

    2016-01-01

    We investigate experimentally the statistical properties of a wind-generated wave field and the spontaneous formation of rogue waves in an annular flume. Unlike many experiments on rogue waves, where waves are mechanically generated, here the wave field is forced naturally by wind as it is in the ocean. What is unique about the present experiment is that the annular geometry of the tank makes waves propagating circularly in an {\\it unlimited-fetch} condition. Within this peculiar framework, we discuss the temporal evolution of the statistical properties of the surface elevation. We show that rogue waves and heavy-tail statistics may develop naturally during the growth of the waves just before the wave height reaches a stationary condition. Our results shed new light on the formation of rogue waves in a natural environment.

  7. Unusual Presentation of Acute Annular Urticaria: A Case Report

    OpenAIRE

    Gilles Guerrier; Jean-Marc Daronat; Roger Deltour

    2011-01-01

    Acute urticarial lesions may display central clearing with ecchymotic or haemorrhagic hue, often misdiagnosed as erythema multiforme, serum-sickness-like reactions, or urticarial vasculitis. We report a case of acute annular urticaria with unusual presentation occurring in a 20-month-old child to emphasize the distinctive morphologic manifestations in a single disease. Clinicians who care for children should be able to differentiate acute urticaria from its clinical mimics. A directed history...

  8. Ignition sequence of an annular multi-injector combustor

    OpenAIRE

    Philip, Maxime; Boileau, Matthieu; Vicquelin, Ronan; Schmitt, Thomas; Durox, Daniel; Bourgoin, Jean-François; Candel, Sébastien

    2013-01-01

    Ignition is a critical process in combustion systems. In aeronautical combustors, altitude relight capacities are required in case of accidental extinction of the chamber. A simultaneous study of light-round ignition in an annular multi-injector combustor has been performed on the experimental and numerical sides. This effort allows a unique comparison to assess the reliability of Large-Eddy Simulation (LES) in such a configuration. Results are presented in fluid dynamics videos.

  9. Large Eddy Simulation of thermoacoustic instabilities in annular combustion chambers

    OpenAIRE

    Wolf, Pierre

    2011-01-01

    Increasingly stringent regulations and the need to tackle rising fuel prices have placed great emphasis on the design of aeronautical gas turbines. This drive towards innovation has resulted sometimes in new concepts being prone to combustion instabilities. Combustion instabilities arise from the coupling of acoustics and combustion. In the particular field of annular combustion chambers, these instabilities often take the form of azimuthal modes. To predict these modes, one must consider the...

  10. The effect of surfactants on the ozonation of o-cresol in aqueous solutions in a rotating packed contactor.

    Science.gov (United States)

    Ku, Young; Ji, Yan-Shiun; Chen, Hua-Wei; Chou, Yiang-Chen; Chang, Ching-Yuan

    2010-02-01

    Steady-state dissolved ozone concentrations were maintained relatively constant for experiments on ozone dissolution conducted in the presence of various amounts of sodium dodecyl sulphate (SDS) and Triton X-100 (TX-100), an anionic surfactant and a nonionic surfactant, respectively. Ozonation in a rotating packed contactor has been shown to be feasible for achieving nearly complete decomposition of o-cresol within about 10 minutes of reaction time for most experiments conducted. The temporal decomposition behaviour of o-cresol in aqueous solution by ozonation was described by a two-step pseudo-first-order reaction kinetics. Even though the presence of SDS and TX-100 slightly affected the decomposition rate constant of o-cresol by ozonation in the rotating packed contactor, the mineralization of total organic carbon was apparently reduced with the addition of SDS and TX-100.

  11. Droplet sizes, dynamics and deposition in vertical annular flow

    International Nuclear Information System (INIS)

    The role of droplets in vertical upwards annular flow is investigated, focusing on the droplet size distributions, dynamics, and deposition phenomena. An experimental program was performed based on a new laser optical technique developed in these laboratories and implemented here for annular flow. This permitted the simultaneous measurement of droplet size, axial and radial velocity. The dependence of droplet size distributions on flow conditions is analyzed. The Upper-Log Normal function proves to be a good model for the size distribution. The mechanism controlling the maximum stable drop size was found to result from the interaction of the pressure fluctuations of the turbulent flow of the gas core with the droplet. The average axial droplet velocity showed a weak dependence on gas rates. This can be explained once the droplet size distribution and droplet size-velocity relationship are analyzed simultaneously. The surprising result from the droplet conditional analysis is that larger droplet travel faster than smaller ones. This dependence cannot be explained if the drag curves used do not take into account the high levels of turbulence present in the gas core in annular flow. If these are considered, then interesting new situations of multiplicity and stability of droplet terminal velocities are encountered. Also, the observed size-velocity relationship can be explained. A droplet deposition is formulated based on the particle inertia control. This permitted the calculation of rates of drop deposition directly from the droplet size and velocities data

  12. Guided Wave Annular Array Sensor Design for Improved Tomographic Imaging

    Science.gov (United States)

    Koduru, Jaya Prakash; Rose, Joseph L.

    2009-03-01

    Guided wave tomography for structural health monitoring is fast emerging as a reliable tool for the detection and monitoring of hotspots in a structure, for any defects arising from corrosion, crack growth etc. To date guided wave tomography has been successfully tested on aircraft wings, pipes, pipe elbows, and weld joints. Structures practically deployed are subjected to harsh environments like exposure to rain, changes in temperature and humidity. A reliable tomography system should take into account these environmental factors to avoid false alarms. The lack of mode control with piezoceramic disk sensors makes it very sensitive to traces of water leading to false alarms. In this study we explore the design of annular array sensors to provide mode control for improved structural tomography, in particular, addressing the false alarm potential of water loading. Clearly defined actuation lines in the phase velocity dispersion curve space are calculated. A dominant in-plane displacement point is found to provide a solution to the water loading problem. The improvement in the tomographic images with the annular array sensors in the presence of water traces is clearly illustrated with a series of experiments. An annular array design philosophy for other problems in NDE/SHM is also discussed.

  13. Treatment of generalized granuloma annulare - a systematic review.

    Science.gov (United States)

    Lukács, J; Schliemann, S; Elsner, P

    2015-08-01

    Granuloma annulare (GA) is a benign inflammatory skin disease. Localized GA is likely to resolve spontaneously, while generalized GA (GGA) is rare and may persist for decades. GGA usually is resistant to a variety of therapeutic modalities and takes a chronic course. The objective of this study was to summarize all reported treatments of generalized granuloma annulare. This is a systematic review based on MEDLINE, Embase and Cochrane Central Register search of articles in English and German and a manual search, between 1980 and 2013, to summarize the treatment of generalized granuloma annulare. Most medical literature on treatment of GGA is limited to individual case reports and small series of patients treated without a control group. Randomized controlled clinical studies are missing. Multiple treatment modalities for GGA were reported including topical and systemic steroids, PUVA, isotretinoin, dapsone, pentoxifylline, hydroxychloroquine, cyclosporine, IFN-γ, potassium iodide, nicotinamide, niacinamide, salicylic acid, dipyridamole, PDT, fumaric acid ester, etanercept, infliximab, adalimumab. While there are numerous case reports of successful treatments in the literature including surgical, medical and phototherapy options, well-designed, randomized, controlled clinical trials are required for an evidence-based treatment of GGA. PMID:25651003

  14. Experimental study on particles mixing in an annular spouted bed

    Energy Technology Data Exchange (ETDEWEB)

    Hao, Huang; Guoxin, Hu [School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200030 (China); Fengchao, Wang [Science and Technology Development Office, Shanghai Jiao Tong University, Shanghai 200030 (China)

    2008-02-15

    A novel annular spouted bed was developed and studied experimentally. The experiments were performed to examine the effects of feeding mode, air velocity and static bed height as well as particle size on particle mixing for different conditions in this device. The results show that feeding by a rotating cone greatly improves particle mixing by homogeneously projecting the particles into the annular bed. For feeding by a rotating cone, the time required to get uniform mixing laterally is shorten almost 10 times less than that for feeding at a fixed point. With increasing air velocity, the axial mixing speed increases more significantly than the lateral mixing speed. The static bed height has important effects on the uniformity of the final admixtures. With increasing static bed height, the degree of mixing of the final mixture (FDM) axially first decreases, then increases, but laterally, the FDM is monotone decreasing. The particles of small size are helpful to raise the mixing speed. In addition, the dead zone in the annular spouted bed was analyzed. (author)

  15. Experimental study on particles mixing in an annular spouted bed

    Energy Technology Data Exchange (ETDEWEB)

    Huang Hao [School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200030 (China); Hu Guoxin [School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200030 (China)], E-mail: hugx@sjtu.edu.cn; Wang Fengchao [Science and Technology Development Office, Shanghai Jiao Tong University, Shanghai 200030 (China)

    2008-02-15

    A novel annular spouted bed was developed and studied experimentally. The experiments were performed to examine the effects of feeding mode, air velocity and static bed height as well as particle size on particle mixing for different conditions in this device. The results show that feeding by a rotating cone greatly improves particle mixing by homogeneously projecting the particles into the annular bed. For feeding by a rotating cone, the time required to get uniform mixing laterally is shorten almost 10 times less than that for feeding at a fixed point. With increasing air velocity, the axial mixing speed increases more significantly than the lateral mixing speed. The static bed height has important effects on the uniformity of the final admixtures. With increasing static bed height, the degree of mixing of the final mixture (FDM) axially first decreases, then increases, but laterally, the FDM is monotone decreasing. The particles of small size are helpful to raise the mixing speed. In addition, the dead zone in the annular spouted bed was analyzed.

  16. Centrifugal Sieve for Size-Segregation/ Beneficiation of Regolith Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Utilizing centrifugal force as the primary body-force, combined with both shearing flow and vibratory motion the proposed centrifugal-sieve separators can provide...

  17. Low-ammonia niche of ammonia-oxidizing archaea in rotating biological contactors of a municipal wastewater treatment plant

    OpenAIRE

    Sauder, L.A.; Peterse, F.; Schouten, S; Neufeld, J. D.

    2012-01-01

    The first step of nitrification is catalysed by both ammonia-oxidizing bacteria (AOB) and archaea (AOA), but physicochemical controls on the relative abundance and function of these two groups are not yet fully understood, especially in freshwater environments. This study investigated ammonia-oxidizing populations in nitrifying rotating biological contactors (RBCs) from a municipal wastewater treatment plant. Individual RBC stages are arranged in series, with nitrification at each stage creat...

  18. Design Optimization of Centrifugal Pump Using Radial Basis Function Metamodels

    OpenAIRE

    Yu Zhang; Jinglai Wu; Yunqing Zhang; Liping Chen

    2014-01-01

    Optimization design of centrifugal pump is a typical multiobjective optimization (MOO) problem. This paper presents an MOO design of centrifugal pump with five decision variables and three objective functions, and a set of centrifugal pumps with various impeller shroud shapes are studied by CFD numerical simulations. The important performance indexes for centrifugal pump such as head, efficiency, and required net positive suction head (NPSHr) are investigated, and the results indicate that th...

  19. Effect of polymer concentration on the structure and performance of PEI hollow fiber membrane contactor for CO2 stripping.

    Science.gov (United States)

    Naim, R; Ismail, A F

    2013-04-15

    A series of polyetherimide (PEI) hollow fiber membranes with various polymer concentrations (13-16 wt.%) for CO2 stripping process in membrane contactor application was fabricated via wet phase inversion method. The PEI membranes were characterized in terms of liquid entry pressure, contact angle, gas permeation and morphology analysis. CO2 stripping performance was investigated via membrane contactor system in a stainless steel module with aqueous diethanolamine as liquid absorbent. The hollow fiber membranes showed decreasing patterns in gas permeation, contact angle, mean pore size and effective surface porosity with increasing polymer concentration. On the contrary, wetting pressure of PEI membranes has enhanced significantly with polymer concentration. Various polymer concentrations have different effects on the CO2 stripping flux in which membrane with 14 wt.% polymer concentration showed the highest stripping flux of 2.7 × 10(-2)mol/m(2)s. From the performance comparison with other commercial membrane, it is anticipated that the PEI membrane has a good prospect in CO2 stripping via membrane contactor.

  20. Gauge design for electrical contactor parts%电工触头零件的检具设计

    Institute of Scientific and Technical Information of China (English)

    赵延岭

    2015-01-01

    概述了电工触头检具的概念、种类、使用要求、设计原则和结构.介绍了检具材料选择、认证验收标准和维护等.分析了检具功能部件设计及原则 ,通过 TeSys接触器触头检具设计 ,举例说明了如何设计检测直观准确、高效可靠的电工触头检具 ,利用设定的检具系统重复性和再现性数据统计表格来快速判断检具是否合格.结果表明 ,在电工触头批量生产中使用检具测量是一种准确、快捷和高效的方法.%In this paper the conceptions ,types ,requirements ,design principles and structure of electrical contactor gauge were introduced ;material selection ,acceptance criteria and maintenance were illustrated ;the design principles of gauge features was analyzed .Taking TeSys contactor gauge design as an example ,it was explained how to design intuitive ;accu-rate ,efficient and reliable electrical contact gauge .The results showed that the use of the gauge measurements in electrical contactor production is an accurate ,fast and efficient way .

  1. Differential white cell count by centrifugal microfluidics.

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Gregory Jon; Tentori, Augusto M.; Schaff, Ulrich Y.

    2010-07-01

    We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generation of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.

  2. APPLICATION ANALYSIS REPORT: RETECH PLASMA CENTRIFUGAL FURNACE

    Science.gov (United States)

    This document is an evaluation of the performance of the Retech, Inc. Plasma Centrifugal Furnace (PCF) and its applicability as a treatment for soils contaminated with organic and/or inorganic compounds. Both the technical and economic aspectsof the technology were examined. A...

  3. Centrifugal Pump Experiment for Chemical Engineering Undergraduates

    Science.gov (United States)

    Vanderslice, Nicholas; Oberto, Richard; Marrero, Thomas R.

    2012-01-01

    The purpose of this paper is to describe a Centrifugal Pump Experiment that provided an experiential learning experience to chemical engineering undergraduates at the University of Missouri in the spring of 2010 in the Unit Operations Laboratory course. Lab equipment was used by senior students with computer-based data and control technology. In…

  4. Performance of a Centrifugal Slurry Pump

    Directory of Open Access Journals (Sweden)

    Hawas Yahya Bajawi

    2014-02-01

    Full Text Available The aim of this study was to experimentally investigate the effect of speed, concentration and size of slurry on the performance of a centrifugal pump. For this purpose a facility was built where the performance of a centrifugal slurry pump was examined using aggregate slurry. Three sizes of slurry with three concentrations and at three impeller speeds were used for the performance investigations of a centrifugal slurry pump. As a reference performance the performance of centrifugal slurry pump was also tested with clean water. The performance of pump has been reported as variations of head, power and efficiency at various flow rates along with the system characteristics of the pump. The results reveal that the pump performance is grossly affected by the type of slurry, its concentration and size. Besides this the variation in speed also affects the performance as is observed in pumps with water. The maximum decrease in the head, with respect to clear water, at the operating point was found to be 47% for aggregate for size 20 mm, 15% concentration and 2600 rpm. The maximum decrement in efficiency at operating point for aggregate was found to be 47% for 4 mm size, 15% concentration and at 2200 rpm. The power increment requirement for aggregate was 9% for 4 mm size, 15% concentration and 2600 rpm.

  5. Positive feedback stabilization of centrifugal compressor surge

    NARCIS (Netherlands)

    Willems, Frank; Heemels, W.P.M.H.; Jager, de Bram; Stoorvogel, Anton A.

    2002-01-01

    Stable operation of axial and centrifugal compressors is limited towards low mass flows due to the occurrence of surge. The stable operating region can be enlarged by active control. In this study, we use a control valve which is fully closed in the desired operating point and only opens to stabiliz

  6. Flow Pattern Characterization for a Centrifugal Impeller

    Science.gov (United States)

    Benavides, Efrén M.

    2014-08-01

    This paper proposes a model for characterizing the flow pattern of a centrifugal impeller attending to the severity of the reverse flow. The model assumes 1) a definition of an escaping particle as the one that flows in every operational point from the trailing edge towards the leading edge of the impeller blades, and 2) a characterization of flow where an operational point is said to have a theoretical flow pattern if it is not possible to establish a fully-reversed escaping particle on it. Therefore, the first part of the article is focused on defining an escaping particle for a centrifugal compressor. The model locates over the map of a centrifugal impeller the line that splits the map in two regions: the region on the right hand side, where a theoretical flow pattern can exist, and the region on the left, where a theoretical flow pattern cannot exist. Therefore, the locus of this line marks a frontier where the expected performance of the impeller cannot be sustained as high as expected. The second part of the article uses a high-performance commercial centrifugal impeller wheel for contrasting the model. A qualitative characterization of the surge line, conclusions and discussions are presented.

  7. 14 CFR 35.35 - Centrifugal load tests.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Centrifugal load tests. 35.35 Section 35.35... STANDARDS: PROPELLERS Tests and Inspections § 35.35 Centrifugal load tests. The applicant must demonstrate... to twice the maximum centrifugal load to which the propeller would be subjected during operation...

  8. Bacterial Cell Surface Damage Due to Centrifugal Compaction

    NARCIS (Netherlands)

    Peterson, Brandon W.; Sharma, Prashant K.; van der Mei, Henny C.; Busscher, Henk J.

    2012-01-01

    Centrifugal damage has been known to alter bacterial cell surface properties and interior structures, including DNA. Very few studies exist on bacterial damage caused by centrifugation because of the difficulty in relating centrifugation speed and container geometry to the damage caused. Here, we pr

  9. Pancreaticoduodenectomy for pancreas carcinoma occurring in the annular pancreas: report of a case

    OpenAIRE

    Kawaida, Hiromichi; KONO, Hiroshi; Watanabe, Mitsuaki; Maki, Akira; Amemiya, Hidetake; Matsuda, Masanori; Fujii, Hideki; Fukasawa, Mitsuharu; Takahashi, Ei; Sano, Katsuhiro; Inoue, Tomohiro

    2015-01-01

    The annular pancreas is a rare congenital anomaly in which a ring of the pancreas parenchyma surrounds the second part of the duodenum. Malignant tumors are extremely rare in patients with an annular pancreas. A 64-year-old man presented with appetite loss and vomiting. Abdominal contrast-enhanced computed tomography (CT) indicated pancreas parenchyma surrounding the second part of the duodenum, and a hypovascular area occupying lesion in the annular pancreas. Subtotal stomach-preserving panc...

  10. Repeated mitral valve replacement in a patient with extensive annular calcification

    OpenAIRE

    Kitamura Tadashi; Fukuda Sachito; Sawada Takahiro; Miura Sumio; Kigawa Ikutaro; Miyairi Takeshi

    2011-01-01

    Abstract Background Mitral valve replacement in the presence of severe annular calcification is a technical challenge. Case report A 47-year-old lady who had undergone mitral and aortic valve replacement for rheumatic disease 27 years before presented with dyspnea. At reoperation, extensive mitral annular calcification was hindering the disc motion of the Starr-Edwards mitral prosthesis. The old prosthesis was removed and a St Jude Medical mechanical valve was implanted after thorough annular...

  11. Life Testing of the Hollow Cathode Plasma Contactor for the ProSEDS Mission

    Science.gov (United States)

    Vaughn, Jason A.; Schneider, Todd A.; Finckenor, Miria M.; Munafo, Paul M. (Technical Monitor)

    2001-01-01

    The Propulsive Small Expendable Deployer System (ProSEDS) mission is designed to provide an on-orbit demonstration of the electrodynamic propulsion capabilities of tethers in space. The ProSEDS experiment will be a secondary payload on a Delta 11 unmanned expendable booster. A 5-km conductive tether is attached to the Delta 11 second stage and collects current from the low Earth orbit (LEO) plasma. A hollow cathode plasma contactor emits the collected electrons from the Delta II, completing the electrical circuit with the ambient plasma. The current flowing through the tether generates thrust based on the Lorentz Force Law. The thrust will be generated opposite to the velocity vector, slowing down the spacecraft and causing it to de-orbit in approximately 14 days compared to the normal 6 months. A 10-km non-conductive tether is between the conductive tether and an endmass containing several scientific instruments. The ProSEDS mission lifetime was set at I day because most of the primary objectives can be met in that time. The extended ProSEDS mission will be for as many days as possible, until the Delta 11 second stage burns up or the tether is severed by a micrometeoroid or space debris particle. The Hollow Cathode Plasma Contactor (HCPC) unit has been designed for a 12-day mission. Because of the science requirements to measure the background ambient plasma, the HCPC must operate on a duty cycle. Later in the ProSEDS mission, the HCPC is operated in a manner to allow charging of the secondary battery. Due to the unusual operating requirements by the ProSEDS mission, a development unit of the HCPC was built for thorough testing. This developmental unit was tested for a simulated ProSEDS mission, with measurements of the ability to start and stop during the duty cycle. These tests also provided valuable data for the ProSEDS software requirements. Qualification tests of the HCPC flight hardware are also discussed.

  12. Pancreaticoduodenectomy for pancreas carcinoma occurring in the annular pancreas: report of a case.

    Science.gov (United States)

    Kawaida, Hiromichi; Kono, Hiroshi; Watanabe, Mitsuaki; Maki, Akira; Amemiya, Hidetake; Matsuda, Masanori; Fujii, Hideki; Fukasawa, Mitsuharu; Takahashi, Ei; Sano, Katsuhiro; Inoue, Tomohiro

    2015-08-01

    The annular pancreas is a rare congenital anomaly in which a ring of the pancreas parenchyma surrounds the second part of the duodenum. Malignant tumors are extremely rare in patients with an annular pancreas. A 64-year-old man presented with appetite loss and vomiting. Abdominal contrast-enhanced computed tomography (CT) indicated pancreas parenchyma surrounding the second part of the duodenum, and a hypovascular area occupying lesion in the annular pancreas. Subtotal stomach-preserving pancreaticoduodenectomy was performed. Histopathology showed pancreatic carcinoma occurring in the complete annular pancreas.

  13. An Annular Gap Acceleration Model for γ-ray Emission of Pulsars

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    If the binding energy of the pulsar's surface is not so high (the case of a neutron star), both negative and positive charges will flow out freely from the surface of the star. An annular free flow model for γ-ray emission of pulsars is suggested. It is emphasized that:(1) Two kinds of acceleration regions (annular and core) need to be taken into account. The annular acceleration region is defined by the magnetic field lines that cross the null charge surface within the light cylinder. (2) If the potential drop in the annular region of a pulsar is high enough (normally the case for young pulsars), charges in both the annular and the core regions could be accelerated and produce primary gamma-rays. Secondary pairs are generated in both regions and stream outwards to power the broadband radiations. (3) The potential drop grows more rapidly in the annular region than in the core region. The annular acceleration process is a key process for producing the observed wide emission beams. (4)The advantages of both the polar cap and outer gap models are retained in this model. The geometric properties of the γ-ray emission from the annular flow are analogous to that presented in a previous work by Qiao et al., which match the observations well. (5) Since charges with different signs leave the pulsar through the annular and the core regions respectively, the current closure problem can be partially solved.

  14. Electron beam diagnostic system using computed tomography and an annular sensor

    Science.gov (United States)

    Elmer, John W.; Teruya, Alan T.

    2014-07-29

    A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by the annular sensor structure.

  15. Electron beam diagnostic system using computed tomography and an annular sensor

    Energy Technology Data Exchange (ETDEWEB)

    Elmer, John W.; Teruya, Alan T.

    2015-08-11

    A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by the annular sensor structure.

  16. Gap instability of laminar flows in eccentric annular channels

    Energy Technology Data Exchange (ETDEWEB)

    Piot, Estelle [Department of Mechanical Engineering, University of Ottawa, Ottawa, Ontario, K1N 6N5 (Canada); Tavoularis, Stavros, E-mail: stavros.tavoularis@uottawa.ca [Department of Mechanical Engineering, University of Ottawa, Ottawa, Ontario, K1N 6N5 (Canada)

    2011-11-15

    Research highlights: Black-Right-Pointing-Triangle The critical Reynolds number for flow instability in the narrow gap of an eccentric annular channel with a diameter ratio of 0.28 was determined experimentally. Black-Right-Pointing-Triangle The critical Reynolds number increases with increasing eccentricity in the range 0.5 to 0.8. Black-Right-Pointing-Triangle The 'gap instability' is attributed to the instability of the two shear layers forming on either side of the gap, as the basic flow has an azimuthal variation that contains two inflection points, thus being potentially linearly unstable. - Abstract: Flow visualization has demonstrated that the critical Reynolds number for flow instability in the narrow gap of an annular channel with a diameter ratio of about 0.28 increases with increasing eccentricity e in the range 0.5 < e < 0.8. The critical Reynolds numbers in the wide gap at all eccentricities and in the narrow gap for 0 < e < 0.5 seem to be insensitive to eccentricity. These observations and comparison of the frequencies of transverse flow oscillations at different Reynolds numbers and different eccentricities demonstrate that at least two distinct instability mechanisms are present in annular flows. The one of particular interest in this work arises in narrow gaps and is attributed to the instability of the two shear layers forming on either side of the gap. Linear stability analysis demonstrated that the basic flow in concentric annuli is stable for the considered diameter ratio and range of Reynolds numbers. In contrast, the basic flow in eccentric annuli has an azimuthal variation that contains two inflection points, thus being potentially linearly unstable.

  17. Annular burnout data from rod-bundle experiments

    International Nuclear Information System (INIS)

    Burnout data for annular flow in a rod bundle are presented for both transient and steady-state conditions. Tests were performed at the Oak Ridge National Laboratory in the Thermal Hydraulic Test Facility (THTF), a pressurized-water loop containing an electrically heated 64-rod bundle. The bundle configuration is typical of later generation pressurized-water reactors with 17 x 17 fuel arrays. Both axial and radial power profiles are flat. All experiments were carried out in upflow with subcooled inlet conditions, insuring accurate flow measurement. Conditions within the bundle were typical of those which could be encountered during a nuclear reactor loss-of-coolant accident

  18. Analysis of Cold Flowfield of Multi—Annular Opposed Jets

    Institute of Scientific and Technical Information of China (English)

    H.F.Zhao; G.C.Benelli

    1992-01-01

    The technique of the use of multi-annular opposed jets as different from using swirl and bluff body creates an excellent recirculation zone with desired size in a large space.The size of ecirculation,the magnitude of reverse velocity and turbulence intensity are much greater than those formed by bluff body.Factors affecting the flowfield include the velocity ration of the opposed jets to the primary air J.the diameter and construction of the opposed jet ring,secondary air velocity and configuration,and confined or unconfined flow condition and so on.This method is a promising way for flame stabilization in combustion technology.

  19. Unusual Presentation of Acute Annular Urticaria: A Case Report

    Directory of Open Access Journals (Sweden)

    Gilles Guerrier

    2011-01-01

    Full Text Available Acute urticarial lesions may display central clearing with ecchymotic or haemorrhagic hue, often misdiagnosed as erythema multiforme, serum-sickness-like reactions, or urticarial vasculitis. We report a case of acute annular urticaria with unusual presentation occurring in a 20-month-old child to emphasize the distinctive morphologic manifestations in a single disease. Clinicians who care for children should be able to differentiate acute urticaria from its clinical mimics. A directed history and physical examination can reliably orientate necessary diagnostic testing and allow for appropriate treatment.

  20. Coexistence of disseminated granuloma annulare and asymptomatic multiple myeloma

    Directory of Open Access Journals (Sweden)

    Şebnem Aktan

    2013-09-01

    Full Text Available Granuloma annulare (GA is a benign inflammatory dermatosis of unknown cause, characterized by necrobiotic dermal papules. Several morphologic forms of GA including localized, disseminated, linear, nodular, perforating, subcutaneous, pustular and arcuate dermal erythema have been reported in the literature. Disseminated GA, a rarely seen form, has been reported in association with some hematopoietic and solid malignancies; however, it has been suggested that the exact causative relationship between malignancy and GA is unclear. We present here a 66-year-old female patient with disseminated GA associated with asymptomatic multipl myeloma.

  1. Exhaust emissions of a double annular combustor: Parametric study

    Science.gov (United States)

    Schultz, D. F.

    1974-01-01

    A full scale double-annular ram-induction combustor designed for Mach 3.0 cruise operation was tested. Emissions of oxides of nitrogen, carbon monoxide, unburned hydrocarbons, and smoke were measured over a range of combustor operating variables including reference velocity, inlet air temperature and pressure, and exit average temperature. ASTM Jet-A fuel was used for these tests. An equation is provided relating oxides of nitrogen emissions as a function of the combustor, operating variables. A small effect of radial fuel staging on reducing exhaust emissions (which were originally quite low) is demonstrated.

  2. Analytic vortex dynamics in an annular Bose-Einstein condensate

    Science.gov (United States)

    Toikka, L. A.; Suominen, K.-A.

    2016-05-01

    We consider analytically the dynamics of an arbitrary number and configuration of vortices in an annular Bose-Einstein condensate obtaining expressions for the free energy and vortex precession rates to logarithmic accuracy. We also obtain lower bounds for the lifetime of a single vortex in the annulus. Our results enable a closed-form analytic treatment of vortex-vortex interactions in the annulus that is exact in the incompressible limit. The incompressible hydrodynamics that is developed here paves the way for more general analytical treatments of vortex dynamics in non-simply-connected geometries.

  3. Meridional Considerations of the Centrifugal Compressor Development

    Directory of Open Access Journals (Sweden)

    C. Xu

    2012-01-01

    Full Text Available Centrifugal compressor developments are interested in using optimization procedures that enable compressor high efficiency and wide operating ranges. Recently, high pressure ratio and efficiency of the centrifugal compressors require impeller design to pay attention to both the blade angle distribution and the meridional profile. The geometry of the blades and the meridional profile are very important contributions of compressor performance and structure reliability. This paper presents some recent studies of meridional impacts of the compressor. Studies indicated that the meridional profiles of the impeller impact the overall compressor efficiency and pressure ratio at the same rotational speed. Proper meridional profiles can improve the compressor efficiency and increase the overall pressure ratio at the same blade back curvature.

  4. High stability design for new centrifugal compressor

    Science.gov (United States)

    Kanki, H.; Katayama, K.; Morii, S.; Mouri, Y.; Umemura, S.; Ozawa, U.; Oda, T.

    1989-01-01

    It is essential that high-performance centrifugal compressors be free of subsynchronous vibrations. A new high-performance centrifugal compressor has been developed by applying the latest rotordynamics knowledge and design techniques: (1) To improve the system damping, a specially designed oil film seal was developed. This seal attained a damping ratio three times that of the conventional design. The oil film seal contains a special damper ring in the seal cartridge. (2) To reduce the destabilizing effect of the labyrinth seal, a special swirl canceler (anti-swirl nozzle) was applied to the balance piston seal. (3) To confirm the system damping margin, the dynamic simulation rotor model test and the full load test applied the vibration exciting test in actual load conditions.

  5. Vibration analysis of large centrifugal pump rotors

    Science.gov (United States)

    Y Zhao, W.; Ge, J. G.; Ma, D.; Li, C. M.; Bao, S. B.

    2013-12-01

    Through the critical speed of centrifugal pumps, internal flow field and the force of the impeller, we analyze centrifugal pump vibration. Using finite element analysis software ANSYS to calculate the natural frequency of the rotor system and the critical speed; with the help of the Fluent software to simulate pump internal flow field, we conclude that speed increase will not cause intense vibration of the fluid in the pump. Using unsteady numerical simulation we discovered that in an impeller suffering transient radial force cyclical change periodically, as well as the frequency size determined by the product of the impeller speed and number of blades, resonance phenomena should make impeller to transient radial force frequency. If wanting to avoid pump resonance when it is running away, the transient radial force frequency should avoid the frequency range which can cause resonance.

  6. Vibration analysis of large centrifugal pump rotors

    International Nuclear Information System (INIS)

    Through the critical speed of centrifugal pumps, internal flow field and the force of the impeller, we analyze centrifugal pump vibration. Using finite element analysis software ANSYS to calculate the natural frequency of the rotor system and the critical speed; with the help of the Fluent software to simulate pump internal flow field, we conclude that speed increase will not cause intense vibration of the fluid in the pump. Using unsteady numerical simulation we discovered that in an impeller suffering transient radial force cyclical change periodically, as well as the frequency size determined by the product of the impeller speed and number of blades, resonance phenomena should make impeller to transient radial force frequency. If wanting to avoid pump resonance when it is running away, the transient radial force frequency should avoid the frequency range which can cause resonance

  7. Condensing Heat Recovery of Centrifugal Chiller

    Institute of Scientific and Technical Information of China (English)

    GONG Guang-cai; JIAO Jun-jun; WANG Li-ping; ZENG Wei

    2009-01-01

    To a kind of centrifugal water chiUer with R22 and about 1745 kW of cooling capacity.a heat exchanger was added between the outlet of compressor and original condenser to get part of or all the condensing heat.Condensing heat can be recovered by compound condensing method,which adopts air-cooling model+wa-ter-cooling model or water-cooling model+water-cooling model at the condensing side of the system.By exergy analysis and experiment research on compound condensing heat recovery of centrifugal chiller,the results are ob-tained that the capability of the whole system increases,the energy efficiency ratio (EER) becomes 3.2~5.0 from 2.2~3.4, which implies the EER increases about 1.0~1.5,the exergy efficiency increases about 10%,and the chiller runs more stably after reformation.

  8. Characterization of biofilm of a rotating biological contactor treating synthetic wastewater.

    Science.gov (United States)

    Singh, V; Mittal, A K

    2012-01-01

    A four-stage rotating biological contactor (RBC) was designed and operated to treat synthetic wastewater containing 1,000 mg/l chemical oxygen demand (COD) and 112 mg/l NH(4)(+)-N. A mixed culture bacterial biofilm was developed consisting of a heterotrophic bacterium Paracoccus pantotrophus, nitrifiers and other heterotrophs. Applying the peculiar characteristics of P. pantotrophus of simultaneous heterotrophic nitrification and aerobic denitrification, high simultaneous removal of carbon and nitrogen could be achieved in the fully aerobic RBC. The microbial community structure of the RBC biofilm was categorized based on the nitrate reduction, biochemical reactions, gram staining and morphology. The presence of P. pantotrophus within the RBC biofilm was confirmed with an array of biochemical tests. Isolates from the four stages of RBC were grouped into complete denitrifiers, incomplete denitrifiers and non-denitrifiers. This categorization showed a higher relative abundance of P. pantotrophus in the first stage as compared with subsequent stages, in which other nitrifiers and heterotrophs were significantly present. High total nitrogen removal of upto 68% was in conformity with observations made using microbial categorization and biochemical tests. The high relative abundance of P. pantotrophus in the biofilm revealed that it could successfully compete with other heterotrophs and autotrophic nitrifiers in mixed bacterial biomass. PMID:22699350

  9. Surface Charging Controlling of the Chinese Space Station with Hollow Cathode Plasma Contactor

    Science.gov (United States)

    Jiang, Kai; Wang, Xianrong; Qin, Xiaogang; Yang, Shengsheng; Yang, Wei; Zhao, Chengxuan; Chen, Yifeng; Shi, Liang; Tang, Daotan; Xie, Kan

    2016-07-01

    A highly charged manned spacecraft threatens the life of an astronaut and extravehicular activity, which can be effectively reduced by controlling the spacecraft surface charging. In this article, the controlling of surface charging on Chinese Space Station (CSS) is investigated, and a method to reduce the negative potential to the CSS is the emission electron with a hollow cathode plasma contactor. The analysis is obtained that the high voltage (HV) solar array of the CSS collecting electron current can reach 4.5 A, which can be eliminated by emitting an adequate electron current on the CSS. The theoretical analysis and experimental results are addressed, when the minimum xenon flow rate of the hollow cathode is 4.0 sccm, the emission electron current can neutralize the collected electron current, which ensures that the potential of the CSS can be controlled in a range of less than 21 V, satisfied with safety voltage. The results can provide a significant reference value to define a flow rate to the potential controlling programme for CSS.

  10. Continuous treatment of coloured industry wastewater using immobilized Phanerochaete chrysosporium in a rotating biological contactor reactor.

    Science.gov (United States)

    Pakshirajan, Kannan; Kheria, Sumeet

    2012-06-30

    Coloured industry wastewaters often contain dyes and other toxic ingredients, and, therefore, pose serious threat to the receiving environment. Among the available methods the eco-friendly biological method has gained maximum attention due to its many advantages over the traditional methods. In the present study, continuous biological treatment of coloured wastewater from a textile dyeing industry was investigated using the white rot fungus Phanerochaete chrysosporium in a rotating biological contactor (RBC) reactor. The raw wastewater was diluted with an equal volume of either distilled water or media containing glucose at varying concentrations to study its effect on the decolourization process. Results revealed that the wastewater could be decolourized to an extent of more than 64% when diluted with media containing glucose; and, a maximum decolourization efficiency of 83% was obtained with 10 g/l glucose concentration. COD removal efficiencies were also found to be consistent with the decolourization efficiencies of the wastewaters. Further, the results were correlated with the enzyme activities of manganese peroxidase (MnP) and lignin peroxidase (LiP) by the fungus, which were found to play some significant role in decolourization of the wastewater. Results of replacing the costly carbon source glucose in the decolourization media with the more cheap molasses, however, revealed very high COD removal efficiency, but low decolourization efficiency of the industry wastewater.

  11. A portable membrane contactor sampler for analysis of noble gases in groundwater.

    Science.gov (United States)

    Matsumoto, Takuya; Han, Liang-Feng; Jaklitsch, Manfred; Aggarwal, Pradeep K

    2013-01-01

    To enable a wider use of dissolved noble gas concentrations and isotope ratios in groundwater studies, we have developed an efficient and portable sampling device using a commercially available membrane contactor. The device separates dissolved gases from a stream of water and collects them in a small copper tube (6 mm in diameter and 100 mm in length with two pinch-off clamps) for noble gas analysis by mass spectrometry. We have examined the performance of the sampler using a tank of homogeneous water prepared in the laboratory and by field testing. We find that our sampling device can extract heavier noble gases (Ar, Kr, and Xe) more efficiently than the lighter ones (He and Ne). An extraction time of about 60 min at a flow rate of 3 L/min is sufficient for all noble gases extracted in the sampler to attain equilibrium with the dissolved phase. The extracted gas sample did not indicate fractionation of helium ((3) He/(4) He) isotopes or other noble gas isotopes. Field performance of the sampling device was tested using a groundwater well in Vienna and results were in excellent agreement with those obtained from the conventional copper tube sampling method.

  12. Macroscale and microscale analysis of Anammox in anaerobic rotating biological contactor

    Institute of Scientific and Technical Information of China (English)

    Yongtao Lv; Lei Wang; Xudong Wang; Yongzhe Yang; Zhiying Wang; Jie Li

    2011-01-01

    Inoculated with conventional anaerobic activated sludge,the Anammox process was successfully developed in an anaerobic rotating biological contactor (AnRBC) fed with a low ratio of C/N synthetic wastewater.Operated in a single point feed mode,the AnRBC removed 92.1% (n =126) of the influent N at the highest surface load of 12 g/(m2.day).The biomass increased by 25% and 17.1 g/(m2.day) of maximum N removal surface load was achieved by elevating flow rate with another feed point.Fluorescence in situ hybridization and polymerase chain reaction analysis indicated that the Anammox genus Candidatus Kuenenia stuttgartiensis dominated the community.Both Anammox and denitrifying activity were detected in biofilm by the application of microelectrodes.In the outer layer of the biofilm (0-2500 μm),nitrite and ammonium consumed simultaneously in a ratio of 1.12/1,revealing the occurrence of Anammox.In the inner layer (> 2500 μm),a decrease of nitrate was caused by denitrification in the absence of nitrite and ammonium.

  13. Bacterial community dynamics in a rotating biological contactor treating 2-fluorophenol-containing wastewater.

    Science.gov (United States)

    Duque, Anouk F; Bessa, Vânia S; Castro, Paula M L

    2014-01-01

    One of the main factors affecting the performance of rotating biological contactors (RBC) is the biofilm characteristics. Therefore, a deep understanding of the microbial population dynamics and structure of the biofilm is mandatory if optimization of organic matter and nutrients removal is targeted. This study focused on the effects of organic shock loads of 2-fluorophenol (2-FP) on the microbial diversity present in an RBC biofilm. The RBC was seeded with activated sludge from a conventional wastewater treatment plant and was operated during 496 days. During the first 126 days, the RBC was subjected to intermittent 2-FP shocks of 25 mg l(-1) and no degradation occurred. Therefore, the reactor was subsequently augmented with a 2-FP-degrading strain (FP1). Afterwards, the RBC had a stable performance when subjected to 2-FP shocks up to 50 mg l(-1) and to a starvation period, as indicated by removal of the compound. Denaturing gradient gel electrophoresis (DGGE) revealed large shifts in microbial communities present in the first and fifth stages, although no clear relation between the sample collection time and spatial factor was found. Phylogenetic affiliation of some predominant members was assessed by direct sequencing of correspondent DGGE bands. Affiliations to α-, β- and δ-Proteobacteria were found. Several bacterial strains isolated from the reactor showed capacity for 2-FP degradation. Strain FP1 was successfully recovered from the biofilm by plating and by DGGE, reinforcing that bioaugmentation was successfully achieved.

  14. Degradation of phenolics, nitrogen-heterocyclics and polynuclear aromatic hydrocarbons in a rotating biological contactor.

    Science.gov (United States)

    Jeswani, Hansa; Mukherji, Suparna

    2012-05-01

    The degradation of phenolics, heterocyclics and polynuclear aromatic hydrocarbons (PAHs) in a synthetic biomass gasifier wastewater with average COD of 1388 mg/L was studied in a three stage rotating biological contactor (RBC) using the pyrene degrader, Exiguobacterium aurantiacum and activated sludge consortia (1:3 v/v). As the organic loading rate (OLR) was varied from 3.3 to 14 g/m(2)/d, the COD removal ranged from 63.3% to 92.6%. Complete removal of all the constituents was observed at the lowest OLR of 3.3g/m(2)/d. At 24h hydraulic retention time (HRT) and OLR of 6.6g/m(2)/d complete removal of pyridine, quinoline and benzene and 85-96% removal of phenol, naphthalene, phenanthrene, fluoranthene and pyrene was observed. E. aurantiacum was found to be the dominant bacteria in the biofilm. Clark's model provided good fits to data for all the three stages of the RBC.

  15. Vacuum interrupter, high reliability component of distribution switches, circuit breakers and contactors

    Institute of Scientific and Technical Information of China (English)

    SLADE Paul G.; LI Wang-pei; MAYO Stephen; SMITH R.Kirkland; TAYLOR Erik D.

    2007-01-01

    The use of vacuum interrupters (VIs) as the current interruption component for switches, circuit breakers, reclosers and contactors operating at distribution voltages has escalated since their introduction in the mid-1950's. This electrical product has developed a dominating position for switching and protecting distribution circuits. VIs are even being introduced into switching products operating at transmission voltages. Among the reasons for the VI's popularity are its compactness, its range of application, its low cost, its superb electrical and mechanical life and its ease of application. Its major advantage is its well-established reliability. In this paper we show how this reliability has been achieved by design, by mechanical life testing and by electrical performance testing. We introduce the "sealed for life" concept for the VI's integrity. We discuss this in terms of what is meant by a practical leak rate for VIs with a life of over 30 years. We show that a simple high voltage withstand test is an easy and effective method for monitoring the long-term vacuum integrity. Finally we evaluate the need for routine inspection of this electrical product when it is used in adverse ambient environments.

  16. Energy-efficient treatment of organic wastewater streams using a rotatable bioelectrochemical contactor (RBEC).

    Science.gov (United States)

    Cheng, Ka Yu; Ho, Goen; Cord-Ruwisch, Ralf

    2012-12-01

    A membraneless bioelectrochemical system - rotatable bio-electrochemical contactor (RBEC) consists of an array of rotatable electrode disks was developed to convert the chemical energy from wastewater organics (acetate) directly into electricity. Each rotatable electrode disk had an upper-air exposing and a lower-water submerging halves. Intermittent rotation (180°) enabled each halve to alternately serve as anode and cathode. Removal of chemical oxygen demand (COD) was increased by 15% (from 0.79 to 0.91 kg COD m(-3) d(-1)) by allowing electron flow from the lower to the upper disk halves. Coupling with a potentiostat could alleviate cathodic limitation and increased COD removal to 1.32 kg COD m(-3) day(-1) (HRT 5h). About 40% of the COD removed was via current, indicating that the biofilm could use the lower half disk as electron acceptor. The RBEC removed COD more energy-efficiently than conventional activated sludge processes as active aeration is not required (0.47 vs. 0.7-2.0 kW h kg COD(-1)).

  17. Rotating biological contactor reactor with biofilm promoting mats for treatment of benzene and xylene containing wastewater.

    Science.gov (United States)

    Sarayu, K; Sandhya, S

    2012-12-01

    A novel rotating biological contactor (RBC) bioreactor immobilized with microorganisms was designed to remove volatile organic compounds (VOC), such as benzene and xylene from emissions, and its performance was investigated. Gas-phase VOCs stripped by air injection were 98 % removed in the RBC when the superficial air flow rate was 375 ml/h (1,193 and 1,226 mg/l of benzene and xylene, respectively). The maximum removal rate was observed to be 1,007 and 1,872 mg/m(3)/day for benzene and xylene, respectively. The concentration profile of benzene and xylene along the RBC was dependent on the air flow rate and the degree of microbial adaptation. Air flow rate and residence time were found to be the most important operational parameters for the RBC reactor. By manipulating these operational parameters, the removal efficiency and capacity of the bioreactor could be enhanced. The kinetic constant K (s) demonstrated a linear relationship that indicated the maximum removal of benzene and xylene in RBC reactor. The phylogenic profile shows the presence of bacterium like Pseudomonas sp., Bacillus sp., and Enterococcus sp., which belonged to the phylum Firmicutes, and Proteobacteria that were responsible for the 98 % organic removal in the RBC.

  18. Performance of an in-situ rotating biological contactor in a recirculating aquaculture system.

    Science.gov (United States)

    Marin, P; Donoso-Bravo, A; Campos, J L; Ruiz-Filippi, G; Chamy, R

    2011-01-01

    The start-up and activation of a nitrifying rotating biological contactor (RBC) and its performance inside a culture tank of rainbow trout were studied. First, in a lab-scale operation, the system was fed with a synthetic medium containing a high ammonia concentration (567 mg NH(4)(+)-N L(-1)) and operated at a high hydraulic retention time (HRT) (6.5 days) to minimize the wash-out of the biomass and promote the biofilm formation. Then, both inlet ammonia concentration and HRT were decreased in order to obtain operational conditions similar to those of the culture tank. During this period, the RBC was able to treat an ammonia loading rate (ALR) of 0.64 g N-NH(4)(+) L(-1) d(-1) with a removal efficiency within 70-100%. Pilot-scale experiments were carried out in culture tanks of rainbow trout. The operation of a recirculating system with the RBC unit was compared with a recirculating system without biological treatment and with a flow-through system. The use of this in-situ nitrifying unit allowed working at a recirculation ratio of 90% without negative effects on either growth or the condition factor of fishes. Up to 70% of ammonia generated was removed and a removal rate of 1.41 g NH(4)(+)-N m(-2) d(-1) was reached. PMID:22156125

  19. Experimental design and statistical analysis in Rotating Disc Contactor (RDC) column

    Science.gov (United States)

    Ismail, Wan Nurul Aiffah; Zakaria, Siti Aisyah; Noor, Nor Fashihah Mohd; Ariffin, Wan Nor Munirah

    2015-12-01

    The purpose of this paper is to examine the performance of the liquid-liquid extraction in Rotating Disc Contactor (RDC) Column that being used in industries. In this study, the performance of small diameter column RDC using the chemical system involving cumene/isobutryric asid/water are analyzed by the method of design of the experiments (DOE) and also Multiple Linear Regression (MLR). The DOE method are used to estimated the effect of four independent. Otherwise, by using Multiple Linear Regression (MLR) is to justify the relationship between the input variables and output variables and also to determine which variable are more influence for both output variable. The input variables for both method include rotor speed (Nr); ratio of flow (Fd); concentration of continuous inlet (Ccin); concentration of dispersed inlet (Cdin); interaction between Nr with Fd; interaction between Nr with Ccin; interaction Nr with Cdin. Meanwhile the output variables are concentration of continuous outlet (Ccout) and concentration of dispersed outlet (Cdout) on RDC column performance. By using this two method, we have two linear model represent two output of Ccout and Cdout for MLR. Lastly, the researcher want to determine which input variable that give more influence to output variable by using this two method. Based on the result, we obtained that rotor speed (Nr) more influence to dependent variable, Ccout and concentration of continuous inlet (Ccin) more influence to dependent variable, Cdout according the two method that was used.

  20. Innovative use of membrane contactor as condenser for heat recovery in carbon capture.

    Science.gov (United States)

    Yan, Shuiping; Zhao, Shuaifei; Wardhaugh, Leigh; Feron, Paul H M

    2015-02-17

    The gas-liquid membrane contactor generally used as a nonselective gas absorption enhancement device is innovatively proposed as a condenser for heat recovery in liquid-absorbent-based carbon capture. The membrane condenser is used as a heat exchanger to recover the latent heat of the exiting vapor from the desorber, and it can help achieve significant energy savings when proper membranes with high heat-transfer coefficients are used. Theoretical thermodynamic analysis of mass and heat transfer in the membrane condensation system shows that heat recovery increases dramatically as inlet gas temperature rises and outlet gas temperature falls. The optimal split mass flow rate is determined by the inlet gas temperature and the overall heat-transfer coefficient in the condensation system. The required membrane area is also strongly dependent on the overall heat-transfer coefficient, particularly at higher inlet gas temperatures. Mass transfer across the membrane has an insignificant effect on heat transfer and heat recovery, suggesting that membrane wetting may not be an issue when a membrane condenser is used for heat recovery. Our analysis provides important insights into the energy recovery performance of the membrane condensation system as well as selection of operational parameters, such as split mass flow rate and membrane area, thickness, and thermal conductivity.

  1. Dispersion-free solvent extraction of Cr(VI) from acidic solutions using hollow fiber contactor.

    Science.gov (United States)

    Alguacil, Francisco J; Alonso, Manuel; Lopez, Félix A; Lopez-Delgado, Aurora; Padilla, Isabel

    2009-10-15

    The use of dispersión-free solvent extraction, through microporous hydrophobic membrane has been investigated. The hollow fiber contactor, with surface area of 1.4 m2 was used to extract Cr(VI) (0.005-0.12 g/L from aqueous sulphuric acidic media (pH 2.5-4.2 +/- 0.05). Several parameters such as extractant concentration, feed acidity and metal concentration in the initial aqueous solution were investigated. Results revealed that 15% v/v Cyanex 923 in Exxsol D-100 as organic phase and feed in the 2.5 pH range, gave optimum extraction (exceeding 95%) of Cr(VI) and it was possible to strip using 10 g/L hydrazine sulfate (also with recoveries exceeding 95%). In this step, Cr(VI) is immediately reduced to the less hazardous Cr(III) state. Results also showed that under the various experimental conditions, chromium(VI) extraction was rate-controlled by the interfacial reaction on the membrane surface. Typical overall mass transfer coefficients values are 4.2 x 10(-5) and 3.6 x 10(-6) cm/s for extraction and stripping operations, respectively.

  2. Centrifuge modeling of soil atmosphere interaction

    OpenAIRE

    CAICEDO, B; TRISTANCHO, J; THOREL, Luc

    2010-01-01

    Atmosphere process of infiltration or evaporation affect the behavior of geotechnical structures located near the soil surface. This paper focuses on the drying process of soils due to evaporation. The scaling laws are analyzed and afterwards the results on applying two cycles of heating and cooling on a soil mass are presented. Based on these results, conclusions about the feasibility of reproducing evaporation on centrifuge models are recommended.

  3. Centrifugal shot blasting. Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    1999-07-01

    At the US Department of Energy (DOE) Fernald Environmental Management Project (FEMP), the Facilities Closure and Demolition Projects Integrated Remedial Design/Remedial Action (RD/RA) work plan calls for the removal of one inch (1 in) depth of concrete surface in areas where contamination with technetium-99 has been identified. This report describes a comparative demonstration between two concrete removal technologies: an innovative system using Centrifugal Shot Blasting (CSB) and a modified baseline technology called a rotary drum planer.

  4. Aerodynamic instabilities in transonic centrifugal compressor

    OpenAIRE

    Buffaz, Nicolas; Trébinjac, Isabelle

    2014-01-01

    International audience This paper presents the analysis of the instabilities inception in a transonic centrifugal com-pressor for different rotation speeds. The analysis was conducted from experimental results obtained with unsteady pressure sensors implanted in the inducer, vaneless diffuser and vaned diffuser. Beyond the stability limit the compressor enters into a deep surge without any precursor, whatever the speed. The surge process is initiated in the vaned diffuser by a massive boun...

  5. Submarine landslide flows simulation through centrifuge modelling

    OpenAIRE

    Gue, Chang Shin

    2012-01-01

    Landslides occur both onshore and offshore. However, little attention has been given to offshore landslides (submarine landslides). Submarine landslides have significant impacts and consequences on offshore and coastal facilities. The unique characteristics of submarine landslides include large mass movements and long travel distances at very gentle slopes. This thesis is concerned with developing centrifuge scaling laws for submarine landslide flows through the study of modell...

  6. Development of centrifuge modelling in geotechnics

    OpenAIRE

    J. Garnier

    2006-01-01

    In order to satisfy similitude conditions, physical modelling in the field of geotechnics requires major facilities, such as shaking tables, calibration chambers and centrifuges. The rapid expansion of centifuge modelling since the beginning of the 1980's can be explained by technological developments in computing, electronics and mechanics as well by enhanced knowledge in the areas of scaling laws, thanks to recent research work on both the properties of reconstituted soils and similitude co...

  7. Centrifugal shot blasting. Innovative technology summary report

    International Nuclear Information System (INIS)

    At the US Department of Energy (DOE) Fernald Environmental Management Project (FEMP), the Facilities Closure and Demolition Projects Integrated Remedial Design/Remedial Action (RD/RA) work plan calls for the removal of one inch (1 in) depth of concrete surface in areas where contamination with technetium-99 has been identified. This report describes a comparative demonstration between two concrete removal technologies: an innovative system using Centrifugal Shot Blasting (CSB) and a modified baseline technology called a rotary drum planer

  8. Potential flow through centrifugal pumps and turbines

    Science.gov (United States)

    Sorensen, E

    1941-01-01

    The methods of conformal transformation up to the present have been applied to the potential flows in the rotation of solid bodies only to a limited extent. This report deals with aspects of centrifugal pumps and turbines such as: the complex potential for rotation, potential for the flow due to the blade rotation, velocities at the blade tip, comparison with "infinite number of blades," and a variable number of blades.

  9. CENTRIFUGAL VIBRATION TEST OF RC PILE FOUNDATION

    Science.gov (United States)

    Higuchi, Shunichi; Tsutsumiuchi, Takahiro; Otsuka, Rinna; Ito, Koji; Ejiri, Joji

    It is necessary that nonlinear responses of structures are clarified by soil-structure interaction analysis for the purpose of evaluating the seismic performances of underground structure or foundation structure. In this research, centrifuge shake table tests of reinforced concrete pile foundation installed in the liquefied ground were conducted. Then, finite element analyses for the tests were conducted to confirm an applicability of the analytical method by comparing the experimental results and analytical results.

  10. Stable isotope enrichment using a plasma centrifuge

    Science.gov (United States)

    Krishnan, Mahadevan; Bures, Brian; Madden, Robert

    2012-10-01

    A primary goal of the Department of Energy's Isotope Development and Production for Research and Applications Program (Isotope Program) within the Office of Nuclear Physics (NP) is to produce isotopes that are in short supply in the U.S. and of which there exists no or insufficient domestic commercial production capability. A vacuum arc plasma centrifuge is a rigid rotor column of metal plasma in which centrifugal forces re-distribute ions radially according to their mass/charge ratio. Early work demonstrated rotation at 2 million rpm and separation of various stable isotopes. The spinning plasma column had a Gaussian flux profile, peaked on the rigid rotor axis. This work adopts a more efficient approach, with the plasma created as a hollow column, wherein the flux is concentrated at larger radii where the centrifugal action is highest. By tailoring the vacuum arc discharge geometry, the rotation rate can also be increased to ˜10 million rpm. Data from Cu, Al and other metal plasmas will be presented and discussed in light of enriched stable isotopes needed for research and medicine.

  11. Centrifugal compressor design choices for chillers

    Energy Technology Data Exchange (ETDEWEB)

    Brasz, J.J. [United Technologies Carrier, New York, NY (United States)

    1999-07-01

    The use of centrifugal compressors in the air conditioning and refrigeration industry is currently limited to large water cooled chillers varying in size from about 0.5 to 6 MW cooling capacity. These systems are primarily used for comfort or process cooling applications. All systems try to chill relatively large amounts of indoor or process water by a few degrees Celsius in a refrigerant evaporator. The heat removed from the chilled water is released together with the heat of compression in a refrigerant condenser to cooling tower water, from where it is discharged to the atmosphere. Different centrifugal compressor design concepts are used by the various chiller manufacturers: single-stage versus multi-stage, vaneless versus vaned diffuser, hermetic versus open-drive motors, shrouded versus open impellers, fixed versus variable diffuser geometry, low- versus high-pressure refrigerant. This variability seems strange for a mature industry like the air conditioning and refrigeration industry. This paper will show that the reason for this variability is the product compromise between the various conflicting system requirements with respect to size, cost, efficiency and refrigerant choice. The different system applications of the chillers (e.g. comfort cooling in a equatorial region versus process cooling in a moderate climate zone) play another major role in selecting an optimal centrifugal compression concept. Some general recommendations will be given for applications where a clear choice can be made. (Author)

  12. Compact, Automated Centrifugal Slide-Staining System

    Science.gov (United States)

    Feeback, Daniel L.; Clarke, Mark S. F.

    2004-01-01

    The Directional Acceleration Vector-Driven Displacement of Fluids (DAVD-DOF) system, under development at the time of reporting the information for this article, would be a relatively compact, automated, centrifugally actuated system for staining blood smears and other microbiological samples on glass microscope slides in either a microgravitational or a normal Earth gravitational environment. The DAVD-DOF concept is a successor to the centrifuge-operated slide stainer (COSS) concept, which was reported in Slide-Staining System for Microgravity or Gravity (MSC-22949), NASA Tech Briefs, Vol. 25, No. 1 (January, 2001), page 64. The COSS includes reservoirs and a staining chamber that contains a microscope slide to which a biological sample is affixed. The staining chamber is sequentially filled with and drained of staining and related liquids from the reservoirs by use of a weighted plunger to force liquid from one reservoir to another at a constant level of hypergravity maintained in a standard swing-bucket centrifuge. In the DAVD-DOF system, a staining chamber containing a sample would also be sequentially filled and emptied, but with important differences. Instead of a simple microscope slide, one would use a special microscope slide on which would be fabricated a network of very small reservoirs and narrow channels connected to a staining chamber (see figure). Unlike in the COSS, displacement of liquid would be effected by use of the weight of the liquid itself, rather than the weight of a plunger.

  13. EM Task 9 - Centrifugal Membrane Filtration

    International Nuclear Information System (INIS)

    This project is designed to establish the utility of a novel centrifugal membrane filtration technology for the remediation of liquid mixed waste streams at US Department of Energy (DOE) facilities in support of the DOE Environmental Management (EM) program. The Energy and Environmental Research Center (EERC) has teamed with SpinTek Membrane Systems, Inc., a small business and owner of the novel centrifugal membrane filtration technology, to establish the applicability of the technology to DOE site remediation and the commercial viability of the technology for liquid mixed waste stream remediation. The technology is a uniquely configured process that makes use of ultrafiltration and centrifugal force to separate suspended and dissolved solids from liquid waste streams, producing a filtered water stream and a low-volume contaminated concentrate stream. This technology has the potential for effective and efficient waste volume minimization, the treatment of liquid tank wastes, the remediation of contaminated groundwater plumes, and the treatment of secondary liquid waste streams from other remediation processes, as well as the liquid waste stream generated during decontamination and decommissioning activities

  14. Shallow water model for horizontal centrifugal casting

    Science.gov (United States)

    Boháček, J.; Kharicha, A.; Ludwig, A.; Wu, M.

    2012-07-01

    A numerical model was proposed to simulate the solidification process of an outer shell of work roll made by the horizontal centrifugal casting technique. Shallow water model was adopted to solve the 2D average flow dynamics of melt spreading and the average temperature distribution inside the centrifugal casting mould by considering the centrifugal force, Coriolis force, viscous force due to zero velocity on the mould wall, gravity, and energy transport by the flow. Additionally, a 1D sub-model was implemented to consider the heat transfer in the radial direction from the solidifying shell to the mould. The solidification front was tracked by fulfilling the Stefan condition. Radiative and convective heat losses were included from both, the free liquid surface and the outer wall of the mould. Several cases were simulated with the following assumed initial conditions: constant height of the liquid metal (10, 20, and 30 mm), uniform temperature of the free liquid surface (1755 K). The simulation results have shown that while the solidification front remained rather flat, the free surface was disturbed by waves. The amplitude of waves increased with the liquid height. Free surface waves diminished as the solidification proceeded.

  15. CFD Analysis of Centrifugal Pump: A Review

    Directory of Open Access Journals (Sweden)

    Narayan P. Jaiswal

    2014-05-01

    Full Text Available The main objective of this work is to understand role of the computational fluid dynamics (CFD technique in analyzing and predicting the performance of centrifugal pump. Computational Fluid Dynamics (CFD is the present day state-of-art technique for fluid flow analysis. The critical review of CFD analysis of CFD analysis of centrifugal pump along with future scope for further improvement is presented in this paper. Different solver like ANSYS-CFX, FLUENT etc can be used for simulations. Shear stress transport model has been found appropriate as turbulence model. Study of pressure contours, velocity contours, flow streamlines etc can be studied by CFD techniques. Unsteady Reynolds Averaged Navier Stokes (URANS equations are solved by solver to get flow simulation results inside centrifugal pump. CFD results has to be validated with testing results or with performance characteristics curves. Performance prediction at design and off-design conditions, parametric study, cavitation analysis, diffuser pump analysis, performance of pump running in turbine mode etc. are possible with CFD simulation techniques.

  16. 交流接触器的常见故障及处理方法%Common failures and processing method of AC contactor

    Institute of Scientific and Technical Information of China (English)

    吕俊霞

    2012-01-01

      AC contactor is the most common application of a kind of electrical appliances in power system. The AC contactor common faults, the fault cause and the specific methods removing the faults are analyzed, including contactor inadequate suction, coil overheat or burn out, interphase short circuit and abnormal arcing etc..%  交流接触器是电力系统应用最普遍的一种电器。分析了交流接触器的常见故障、产生故障的原因及排除故障的具体方法,主要涉及接触器吸力不足、线圈过热或烧坏、相间短路、灭弧装置不正常灭弧等。

  17. Electrorheological damper with annular ducts for seismic protection applications

    Science.gov (United States)

    Makris, Nicos; Burton, Scott A.; Taylor, Douglas P.

    1996-10-01

    This paper presents the design, analysis, testing and modeling of an electrorheological (ER) fluid damper developed for vibration and seismic protection of civil structures. The damper consists of a main cylinder and a piston rod that pushes an ER fluid through a stationary annular duct. The behavior of the damper can be approximated with Hagen - Poiseuille flow theory. The basic equations that describe the fluid flow across an annular duct are derived. Experimental results on the damper response with and without the presence of electric field are presented. As the rate of deformation increases, viscous stresses prevail over field-induced yield stresses and a smaller fraction of the total damper force can be controlled. Simple physically motivated phenomenological models are considered to approximate the damper response with and without the presence of electric field. Subsequently, the performance of a multilayer neural network constructed and trained by an efficient algorithm known as the Dependence Identification Algorithm is examined to predict the response of the electrorheological damper. A combination of a simple phenomenological model and a neural network is then proposed as a practical tool to approximate the nonlinear and velocity-dependent damper response.

  18. A compact annular ring microstrip antenna for WSN applications.

    Science.gov (United States)

    Wang, Daihua; Song, Linli; Zhou, Hanchang; Zhang, Zhijie

    2012-01-01

    A compact annular ring microstrip antenna was proposed for a wireless sensor network (WSN) application in the 2.4 GHz band. In this paper the major considerations of the conformal antenna design were the compact size and the impact on antenna's performance of a steel installation base. By using a chip resistor of large resistance (120 Ω) the antenna size was reduced to 38% of that a conventional annular ring patch antenna. With the addition of the steel installation base the resonant frequency of the antenna increases about 4.2% and the bandwidth reduces from 17.5% to 11.7% by adjusting the load resistance simultaneously. Several key parameters were discussed and optimized, and the antenna was fabricated and its performance measured. The antenna is well matched at 2.4 GHz with 34.2 dB return loss and -2.5 dBi peak gain. Meanwhile, it exhibits excellent radiation patterns with very low cross-polarization levels.

  19. A Compact Annular Ring Microstrip Antenna for WSN Applications

    Directory of Open Access Journals (Sweden)

    Daihua Wang

    2012-06-01

    Full Text Available A compact annular ring microstrip antenna was proposed for a wireless sensor network (WSN application in the 2.4 GHz band. In this paper the major considerations of the conformal antenna design were the compact size and the impact on antenna’s performance of a steel installation base. By using a chip resistor of large resistance (120 Ω the antenna size was reduced to 38% of that a conventional annular ring patch antenna. With the addition of the steel installation base the resonant frequency of the antenna increases about 4.2% and the bandwidth reduces from 17.5% to 11.7% by adjusting the load resistance simultaneously. Several key parameters were discussed and optimized, and the antenna was fabricated and its performance measured. The antenna is well matched at 2.4 GHz with 34.2 dB return loss and –2.5 dBi peak gain. Meanwhile, it exhibits excellent radiation patterns with very low cross-polarization levels.

  20. Annular bullous lesions with atypical erythema multiforme in leprosy.

    Science.gov (United States)

    Shah, Aishani; Mahajan, Rashmi; Ninama, Kishan; Bilimoria, Freny

    2014-09-01

    Erythema nodosum leprosum (ENL) is an immune complex-mediated reaction that may complicate the course of multibacillary leprosy. Bullous lesions in Type II reaction, though reported, are exceedingly rare. We report the case of a 32 year old female patient who presented initially at our OPD with erythema nodosum. Cutaneous examination revealed impaired sensation over dorsum of right foot and thickened right lateral popliteal nerve. Slit skin smear (SSS) from ear lobes revealed AFB with a bacteriological index of 2+. She was started on MDT, tablet ofloxacin 200 mg twice a day, and 30 mg oral prednisolone. Two months later, she presented with generalised pruritus, large target lesions over the back, and hemorrhagic bullae over lower extremities and annular pattern of bullae, over both arms. A SSS was repeated which was positive for AFB. Histopathology from bullous lesions was consistent with ENL. Direct Immunofluorescence (DIF) study was negative. Our patient improved rapidly after she was started on thalidomide 100 mg twice daily, with withdrawal of ofloxacin. Erythema Multiforme (EMF) and annular bullous lesions have been reported in patients on treatment with ofloxacin. This case is being presented due to the unusual and varied manifestation of Type II lepra reaction in a 34 year old female patient.

  1. Investigation of azimuthal staging concepts in annular gas turbines

    Science.gov (United States)

    Noiray, Nicolas; Bothien, Mirko; Schuermans, Bruno

    2011-10-01

    In this work, the influence of azimuthal staging concepts on the thermoacoustic behavior of annular combustion chambers is assessed theoretically and numerically. Staging is a well-known and effective method to abate thermoacoustic pulsations in combustion chambers. However, in the case of, for example, fuel staging the associated inhomogeneity of equivalence ratio may result in increased levels of NOx emissions. In order to minimize this unwanted effect a staging concept is required in which the transfer functions of the burners are changed while affecting the equivalence ratio as little as possible. In order to achieve this goal, a theoretical framework for predicting the influence of staging concepts on pulsations has been developed. Both linear and nonlinear analytical approaches are presented and it is shown that the dynamics of azimuthal modes can be described by coupled Van der Pol oscillators. A criterion based on the thermoacoustic coupling strength and on the asymmetry degree provides the modal behavior in the annular combustor, i.e. standing or traveling waves. The model predictions have been verified by numerical simulations of a heavy-duty gas turbine using an in-house thermoacoustic network-modeling tool. The interaction between the heat release of the flame and the acoustic field was modeled using measured transfer functions and source terms. These numerical simulations confirmed the original theoretical considerations.

  2. Portal annular pancreas: a systematic review of a clinical challenge.

    Science.gov (United States)

    Harnoss, Jonathan M; Harnoss, Julian C; Diener, Markus K; Contin, Pietro; Ulrich, Alexis B; Büchler, Markus W; Schmitz-Winnenthal, Friedrich H

    2014-10-01

    Portal annular pancreas (PAP) is an asymptomatic congenital pancreas anomaly, in which portal and/or mesenteric veins are encased by pancreas tissue. The aim of the study was to determine the role of PAP in pancreatic surgery as well as its management and potential complication, specifically, postoperative pancreatic fistula (POPF).On the basis of a case report, the MEDLINE and ISI Web of Science databases were systematically reviewed up to September 2012. All articles describing a case of PAP were considered.In summary, 21 studies with 59 cases were included. The overall prevalence of PAP was 2.4% and the patients' mean (SD) age was 55.9 (16.2) years. The POPF rate in patients with PAP (12 pancreaticoduodenectomies and 3 distal pancreatectomies) was 46.7% (in accordance with the definition of the International Study Group of Pancreatic Surgery).Portal annular pancreas is a quite unattended pancreatic variant with high prevalence and therefore still remains a clinical challenge to avoid postoperative complications. To decrease the risk for POPF, attentive preoperative diagnostics should also focus on PAP. In pancreaticoduodenectomy, a shift of the resection plane to the pancreas tail should be considered; in extensive pancreatectomy, coverage of the pancreatic remnant by the falciform ligament could be a treatment option.

  3. The Growth of Instabilities in Annular Liquid Sheets

    Energy Technology Data Exchange (ETDEWEB)

    Duke, Daniel J.; Honnery, Damon R; Soria, Julio

    2015-11-01

    An annular liquid sheet surrounded by parallel co-flowing gas is an effective atomiser. However, the initial instabilities which determine the primary break-up of the liquid sheet are not well understood. Lack of agreement on the influence of the boundary conditions and the non-dimension scaling of the initial instability persists between theoretical stability analyses and experiments. To address this matter, we have undertaken an experimental parametric study of an aerodynamically-driven, non-swirling annular water sheet. The effects of sheet thickness, inner and outer gas-liquid momentum ratio were investigated over an order of magnitude variation in Reynolds and Weber number. From high-speed image correlation measurements in the near-nozzle region, we propose new empirical correlations for the frequency of the instability as a function of the total gas-liquid momentum ratio, with good non-dimensional collapse. From analysis of the instability velocity probability densities, we find two persistent and distinct superimposed instabilities with different growth rates. The first is a short-lived, rapidly saturating sawtooth-like instability. The second is a slower-growing stochastic instability which persists through the break-up of the sheet. The presence of multiple instabilities whose growth rates do not strongly correlate with the shear velocities may explain some of the discrepancies between experiments and stability analyses.

  4. Non-null annular subaperture stitching interferometry for aspheric test

    Science.gov (United States)

    Zhang, Lei; Liu, Dong; Shi, Tu; Yang, Yongying; Chong, Shiyao; Miao, Liang; Huang, Wei; Shen, Yibing; Bai, Jian

    2015-10-01

    A non-null annular subaperture stitching interferometry (NASSI), combining the subaperture stitching idea and non-null test method, is proposed for steep aspheric testing. Compared with standard annular subaperture stitching interferometry (ASSI), a partial null lens (PNL) is employed as an alternative to the transmission sphere, to generate different aspherical wavefronts as the references. The coverage subaperture number would thus be reduced greatly for the better performance of aspherical wavefronts in matching the local slope of aspheric surfaces. Instead of various mathematical stitching algorithms, a simultaneous reverse optimizing reconstruction (SROR) method based on system modeling and ray tracing is proposed for full aperture figure error reconstruction. All the subaperture measurements are simulated simultaneously with a multi-configuration model in a ray-tracing program, including the interferometric system modeling and subaperture misalignments modeling. With the multi-configuration model, full aperture figure error would be extracted in form of Zernike polynomials from subapertures wavefront data by the SROR method. This method concurrently accomplishes subaperture retrace error and misalignment correction, requiring neither complex mathematical algorithms nor subaperture overlaps. A numerical simulation exhibits the comparison of the performance of the NASSI and standard ASSI, which demonstrates the high accuracy of the NASSI in testing steep aspheric. Experimental results of NASSI are shown to be in good agreement with that of Zygo® VerifireTM Asphere interferometer.

  5. A new model of centrifugal blood pump for cardiopulmonary bypass: design improvement, performance, and hemolysis tests.

    Science.gov (United States)

    Leme, Juliana; Fonseca, Jeison; Bock, Eduardo; da Silva, Cibele; da Silva, Bruno Utiyama; Dos Santos, Alex Eugênio; Dinkhuysen, Jarbas; Andrade, Aron; Biscegli, José F

    2011-05-01

    A new model of blood pump for cardiopulmonary bypass (CPB) application has been developed and evaluated in our laboratories. Inside the pump housing is a spiral impeller that is conically shaped and has threads on its surface. Worm gears provide an axial motion of the blood column. Rotational motion of the conical shape generates a centrifugal pumping effect and improves pumping performance. One annular magnet with six poles is inside the impeller, providing magnetic coupling to a brushless direct current motor. In order to study the pumping performance, a mock loop system was assembled. Mock loop was composed of Tygon tubes (Saint-Gobain Corporation, Courbevoie, France), oxygenator, digital flowmeter, pressure monitor, electronic driver, and adjustable clamp for flow control. Experiments were performed on six prototypes with small differences in their design. Each prototype was tested and flow and pressure data were obtained for rotational speed of 1000, 1500, 2000, 2500, and 3000 rpm. Hemolysis was studied using pumps with different internal gap sizes (1.35, 1.45, 1.55, and 1.7 mm). Hemolysis tests simulated CPB application with flow rate of 5 L/min against total pressure head of 350 mm Hg. The results from six prototypes were satisfactory, compared to the results from the literature. However, prototype #6 showed the best results. Best hemolysis results were observed with a gap of 1.45 mm, and showed a normalized index of hemolysis of 0.013 g/100 L. When combined, axial and centrifugal pumping principles produce better hydrodynamic performance without increasing hemolysis.

  6. Based on prole ac contactor automatic assembly system research%基于Pro/E的交流接触器自动装配系统研究

    Institute of Scientific and Technical Information of China (English)

    王军浩; 杨丽华; 厉鹏

    2014-01-01

    Parts for ac contactor with proltoolklt application interface is provided for the secondary development of pro/engineer, the realization of ac contactor automatic assembly parts.Through automatic assembly can improve the design efficiency. shorten product development cycle.%针对交流接触器常用零件,利用Pro/TOOLKIT应用程序接口对Pro/ENGINEER进行二次开发,实现交流接触器零部件的自动装配。通过自动装配可以提高设计效率,缩短产品开发周期。

  7. Research on Environmental Adaptation Experiments for Contactors%接触器高原环境适应性试验研究

    Institute of Scientific and Technical Information of China (English)

    田华

    2015-01-01

    To enhance the capability and reliability of contactors in specific high altitude environment, this paper assesses the environmental adaptation experiments for contactors.%为了增强接触器在高原环境条件下的适应性能,提高接触器在高原特殊环境条件下的可靠性水平,特此提出对接触器应通过的环境适应性试验提出了考核评价。

  8. Core-annular flow through a horizontal pipe: Hydrodynamic counterbalancing of buoyancy force on core

    NARCIS (Netherlands)

    Ooms, G.; Vuik, C.; Poesio, P.

    2007-01-01

    A theoretical investigation has been made of core-annular flow: the flow of a high-viscosity liquid core surrounded by a low-viscosity liquid annular layer through a horizontal pipe. Special attention is paid to the question of how the buoyancy force on the core, caused by a density difference betwe

  9. DC intrinsic Josephson effect in 1{mu}m-lateral-size annular Bi-2212 stacks

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S.J.; Yamashita, T. [Tohoku Univ., Sendai (Japan). Research Inst. of Electrical Comunication; Latyshev, Y.I.; Pavlenko, V.N. [Tohoku Univ., Sendai (Japan); Inst of Radio-Engineerig and Electronics Russian Academic of Sciences, Moscow (Russian Federation)

    1999-11-10

    Small annular junctions were the subjects of particular interest last decade because of possibility of flux trapping (see, e.g. [1]). Related magnetic field can contain radial component affecting Josephson critical current. Here we report on the first studies of intrinsic dc Josephson effect [2] in small annular type Bi-2212 mesas and its sensitivity to the trapped flux. (translated by NEDO)

  10. A magnetorheological valve with both annular and radial fluid flow resistance gaps

    International Nuclear Information System (INIS)

    In order to increase the efficiency of magnetorheological (MR) valves, Ai et al (2006) proposed an MR valve simultaneously possessing annular and radial fluid flow resistance channels with the assumption that the magnetic flux densities at the annular and radial fluid flow gaps are identical. In this paper, an MR valve simultaneously possessing annular and radial fluid flow resistance channels is designed, fabricated, modeled and tested. A model for the developed MR valve is produced and its performances are theoretically predicted based on the average magnetic flux densities in the annular and radial fluid flow gaps through finite element analysis. The theoretical results for the developed MR valve are compared with the experimental results. In addition, the performances of the developed MR valve are theoretically and experimentally compared with those of the MR valve with only annular fluid flow gaps. It has been shown that the theoretical results match well with the experimental results. Mainly attributed to the radial fluid flow gaps, the pressure drops across the MR valve with both annular and radial fluid flow gaps are larger than those across the MR valve with only annular fluid flow gaps for varying valve parameters. The radial fluid flow gaps in the MR valve can reach a higher efficiency and larger controllable range than those by annular fluid flow gaps to some extent

  11. Erythema annulare centrifugum as presenting sign of activation of breast cancer*

    Science.gov (United States)

    Topal, Ilteris Oguz; Topal, Yunus; Sargan, Aytul; Duman, Hatice; Gungor, Sule; Goncu, Ozgur Emek Kocaturk; Ozekinci, Selver

    2015-01-01

    Erythema annulare centrifugum is a figurate erythema of unknown etiology. It has been associated with many different entities, including infections, food allergy, drug reactions and malignant neoplasms. Herein, we report a case of erythema annulare centrifugum as presenting sign of activation of breastcancer. PMID:26734884

  12. Erythema annulare centrifugum as presenting sign of activation of breast cancer.

    Science.gov (United States)

    Topal, Ilteris Oguz; Topal, Yunus; Sargan, Aytul; Duman, Hatice; Gungor, Sule; Goncu, Ozgur Emek Kocaturk; Ozekinci, Selver

    2015-01-01

    Erythema annulare centrifugum is a figurate erythema of unknown etiology. It has been associated with many different entities, including infections, food allergy, drug reactions and malignant neoplasms. Herein, we report a case of erythema annulare centrifugum as presenting sign of activation of breastcancer.

  13. Preparation of Bovine Serum Albumin (BSA) nanoparticles by desolvation using a membrane contactor: a new tool for large scale production.

    Science.gov (United States)

    Yedomon, B; Fessi, H; Charcosset, C

    2013-11-01

    Albumin nanoparticles are attractive drug delivery systems as they can be prepared under soft conditions and incorporate several kinds of molecules. The aim of this study was to upscale the desolvation process for preparing Bovine Serum Albumin (BSA) nanoparticles using a membrane contactor. At a first step, the BSA nanoparticles were prepared at small scale using a syringe pump. BSA nanoparticles of 139 nm in size, with a polydispersity index of 0.046, were obtained at the optimal conditions: pH 8.2, 100 mg mL(-1) BSA albumin solution (2 mL), and 1 mL min(-1) flow rate of ethanol addition (8 mL). The upscaling with a membrane contactor was achieved by permeating ethanol through the pores of a Shirasu Porous Glass (SPG Technology Co., Japan) membrane and circulating the aqueous phase tangentially to the membrane surface. By increasing the pressure of the ethanol from 1 to 2.7 bars, a progressive decrease in nanoparticle size was obtained with a high nanoparticles yield (around 94-96%). In addition, the flow rate of the circulating phase did not affect the BSA nanoparticle characteristics. At the optimal conditions (pH 8.2, 100 mg mL(-1) BSA albumin solution, pressure of ethanol 2.7 bars, flow rate of the circulating phase 30.7 mL s(-1)), the BSA nanoparticles showed similar characteristics to those obtained with the syringe pump. Large batches of BSA nanoparticles were prepared up to 10 g BSA. The BSA nanoparticles were stable at least during 2 months at 4 °C, and their characteristics were reproducible. It was then concluded that the membrane contactor technique could be a suitable method for the preparation of albumin nanoparticles at large scale with properties similar to that obtained at small scale.

  14. Entrance and exit region friction factor models for annular seal analysis. Ph.D. Thesis

    Science.gov (United States)

    Elrod, David Alan

    1988-01-01

    The Mach number definition and boundary conditions in Nelson's nominally-centered, annular gas seal analysis are revised. A method is described for determining the wall shear stress characteristics of an annular gas seal experimentally. Two friction factor models are developed for annular seal analysis; one model is based on flat-plate flow theory; the other uses empirical entrance and exit region friction factors. The friction factor predictions of the models are compared to experimental results. Each friction model is used in an annular gas seal analysis. The seal characteristics predicted by the two seal analyses are compared to experimental results and to the predictions of Nelson's analysis. The comparisons are for smooth-rotor seals with smooth and honeycomb stators. The comparisons show that the analysis which uses empirical entrance and exit region shear stress models predicts the static and stability characteristics of annular gas seals better than the other analyses. The analyses predict direct stiffness poorly.

  15. Annular core liquid-salt cooled reactor with multiple fuel and blanket zones

    Science.gov (United States)

    Peterson, Per F.

    2013-05-14

    A liquid fluoride salt cooled, high temperature reactor having a reactor vessel with a pebble-bed reactor core. The reactor core comprises a pebble injection inlet located at a bottom end of the reactor core and a pebble defueling outlet located at a top end of the reactor core, an inner reflector, outer reflector, and an annular pebble-bed region disposed in between the inner reflector and outer reflector. The annular pebble-bed region comprises an annular channel configured for receiving pebble fuel at the pebble injection inlet, the pebble fuel comprising a combination of seed and blanket pebbles having a density lower than the coolant such that the pebbles have positive buoyancy and migrate upward in said annular pebble-bed region toward the defueling outlet. The annular pebble-bed region comprises alternating radial layers of seed pebbles and blanket pebbles.

  16. Studies of efficiency in a perforated rotating disc contactor using a polymer-polymer aqueous two-phase systems

    Directory of Open Access Journals (Sweden)

    L. A. Sarubbo

    2005-09-01

    Full Text Available The mass transfer process in a perforated rotating disc contactor (PRDC using a polymer-polymer aqueous two-phase system was investigated. The results show that the efficiency did not show a regular trend with the increase of the dispersed phase velocity and increased with the rotation velocity. The separation efficiency was higher for three rotating discs than for four discs. The increase in tie-line length decreased the efficiency. The separation efficiency reached high values, about 96% under conditions studied in this work.

  17. Hydrodynamic study of fine metallic powders in an original spouted bed contactor in view of chemical vapor deposition treatments

    OpenAIRE

    Caussat, Brigitte; Juarez, Fernando L.; Vahlas, Constantin

    2006-01-01

    An original gas–solid contactor was developed so as to treat by chemical vapor deposition, fine (mean diameter 23 μm) and dense (bulk density 7700 kg/m3) NiCoCrAlYTa powders with large size distribution. In order to avoid the presence of a distributor in the reactive zone, a spouted bed configuration was selected, consisting in a glass cylindrical column associated through a 60° cone to an inlet tube, connected at its bottom to a grid so as to support the powders at rest. A hydrodynamic study...

  18. Comparative non-dispersive solvent extraction of uranium and thorium using a hollow fiber contactor containing TBP/DHOA

    International Nuclear Information System (INIS)

    Non-dispersive solvent extraction of Uranium and Thorium was carried out from nitric acid medium using hollow fiber contactor containing TBP and DHOA as the carrier extractants. The effect of flow rate was studied while carrying out the extraction studies in counter current mode using 10 g/L solutions of the metal ions in 3 M HNO3 and 50 mL/minute was found to be most suitable for better separation efficiency. Stripping studies were also carried out using deionized water as the strippant for both the metal ions. (author)

  19. ELECTRO-HYDRAULIC SERVO SYSTEM IN THE CENTRIFUGE FIELD

    Institute of Scientific and Technical Information of China (English)

    Dong Longlei; Yan Guirong; Li Ronglin

    2004-01-01

    The mechanical characteristics of the electro-hydraulic servo system in the centrifuge field are analyzed.The hydraulic pressure law in the centrifuge field indicates the existence of the centrifuge hydraulic pressure.The mechanical characteristics of the slide-valve and the dual nozzle flapper valve are studied,and it is found that the centrifuge field can not only increase the driving force or moment of the function units,but also decrease the stability of the components.Finally by applying Gauss minimum constraint principle,the dynamic model of the electro-hydraulic vibrator in the centrifuge field is established,and the mechanical restriction of the system is also presented.The study will be helpful for the realization of the combined vibration and centrifuge test system.

  20. Pressure Pulsation Signal Analysis for Centrifugal Compressor Blade Crack Determination

    OpenAIRE

    Hongkun Li; Xuefeng Zhang; Xiaowen Zhang; Shuhua Yang; Fujian Xu

    2014-01-01

    Blade is a key piece of component for centrifugal compressor. But blade crack could usually occur as blade suffers from the effect of centrifugal forces, gas pressure, friction force, and so on. It could lead to blade failure and centrifugal compressor closing down. Therefore, it is important for blade crack early warning. It is difficult to determine blade crack as the information is weak. In this research, a pressure pulsation (PP) sensor installed in vicinity to the crack area is used to d...

  1. Numerical Investigations on the Transient Performance of a Centrifugal Pump

    OpenAIRE

    Asim, Taimoor; Mishra, Rakesh

    2015-01-01

    Centrifugal pumps are an integral part of plants used in process industries. The flow structure within a centrifugal pump is very complex due to the interaction between the rotating impeller and the geometric features around it. In the present study, numerical investigations on a centrifugal pump have been carried out using a Computational Fluid Dynamics (CFD) based solver. This study employs finite volume technique in order to analyse the influence of variations in the rotational speed of th...

  2. Latex Micro-balloon Pumping in Centrifugal Microfluidic Platforms

    OpenAIRE

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Al-Faqheri, Wisam; Thio, Tzer Hwai Gilbert; Kazemzadeh, Amin; Wadi harun, Sulaiman; Madou, Marc

    2014-01-01

    Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-stepped processes on a single microfluidics disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a...

  3. pH-sensitive micelles for targeted drug delivery prepared using a novel membrane contactor method.

    Science.gov (United States)

    Laouini, Abdallah; Koutroumanis, Konstantinos P; Charcosset, Catherine; Georgiadou, Stella; Fessi, Hatem; Holdich, Richard G; Vladisavljević, Goran T

    2013-09-25

    A novel membrane contactor method was used to produce size-controlled poly(ethylene glycol)-b-polycaprolactone (PEG-PCL) copolymer micelles composed of diblock copolymers with different average molecular weights, Mn (9200 or 10,400 Da) and hydrophilic fractions, f (0.67 or 0.59). By injecting 570 L m(-2) h(-1) of the organic phase (a 1 mg mL(-1) solution of PEG-PCL in tetrahydrofuran) through a microengineered nickel membrane with a hexagonal pore array and 200 μm pore spacing into deionized water agitated at 700 rpm, the micelle size linearly increased from 92 nm for a 5-μm pore size to 165 nm for a 40-μm pore size. The micelle size was finely tuned by the agitation rate, transmembrane flux and aqueous to organic phase ratio. An encapsulation efficiency of 89% and a drug loading of ~75% (w/w) were achieved when a hydrophobic drug (vitamin E) was entrapped within the micelles, as determined by ultracentrifugation method. The drug-loaded micelles had a mean size of 146 ± 7 nm, a polydispersity index of 0.09 ± 0.01, and a ζ potential of -19.5 ± 0.2 mV. When drug-loaded micelles where stored for 50 h, a pH sensitive drug release was achieved and a maximum amount of vitamin E (23%) was released at the pH of 1.9. When a pH-sensitive hydrazone bond was incorporated between PEG and PCL blocks, no significant change in micelle size was observed at the same micellization conditions.

  4. Ammonia removal in the carbon contactor of a hybrid membrane process.

    Science.gov (United States)

    Stoquart, Céline; Servais, Pierre; Barbeau, Benoit

    2014-12-15

    The hybrid membrane process (HMP) coupling powdered activated carbon (PAC) and low-pressure membrane filtration is emerging as a promising new option to remove dissolved contaminants from drinking water. Yet, defining optimal HMP operating conditions has not been confirmed. In this study, ammonia removal occurring in the PAC contactor of an HMP was simulated at lab-scale. Kinetics were monitored using three PAC concentrations (1-5-10 g L(-1)), three PAC ages (0-10-60 days), two temperatures (7-22 °C), in ambient influent condition (100 μg N-NH4 L(-1)) as well as with a simulated peak pollution scenario (1000 μg N-NH4L(-1)). The following conclusions were drawn: i) Using a colonized PAC in the HMP is essential to reach complete ammonia removal, ii) an older PAC offers a higher resilience to temperature decrease as well as lower operating costs; ii) PAC concentration inside the HMP reactor is not a key operating parameter as under the conditions tested, PAC colonization was not limited by the available surface; iii) ammonia flux limited biomass growth and iv) hydraulic retention time was a critical parameter. In the case of a peak pollution, the process was most probably phosphate-limited but a mixed adsorption/nitrification still allowed reaching a 50% ammonia removal. Finally, a kinetic model based on these experiments is proposed to predict ammonia removal occurring in the PAC reactor of the HMP. The model determines the relative importance of the adsorption and biological oxidation of ammonia on colonized PAC, and demonstrates the combined role of nitrification and residual adsorption capacity of colonized PAC.

  5. Biofilm growth of Chlorella sorokiniana in a rotating biological contactor based photobioreactor.

    Science.gov (United States)

    Blanken, W; Janssen, M; Cuaresma, M; Libor, Z; Bhaiji, T; Wijffels, R H

    2014-12-01

    Microalgae biofilms could be used as a production platform for microalgae biomass. In this study, a photobioreactor design based on a rotating biological contactor (RBC) was used as a production platform for microalgae biomass cultivated in biofilm. In the photobioreactor, referred to as Algadisk, microalgae grow in biofilm on vertical rotating disks partially submerged in a growth medium. The objective is to evaluate the potential of the Algadisk photobioreactor with respect to the effects of disk roughness, disk rotation speed and CO2 concentration. These objectives where evaluated in relationship to productivity, photosynthetic efficiency, and long-term cultivation stability in a lab-scale Algadisk system. Although the lab-scale Algadisk system is used, operation parameters evaluated are relevant for scale-up. Chlorella Sorokiniana was used as model microalgae. In the lab-scale Algadisk reactor, productivity of 20.1 ± 0.7 g per m(2) disk surface per day and a biomass yield on light of 0.9 ± 0.04 g dry weight biomass per mol photons were obtained. Different disk rotation speeds did demonstrate minimal effects on biofilm growth and on the diffusion of substrate into the biofilm. CO2 limitation, however, drastically reduced productivity to 2-4 g per m(2) disk surface per day. Productivity could be maintained over a period of 21 weeks without re-inoculation of the Algadisk. Productivity decreased under extreme conditions such as pH 9-10, temperature above 40°C, and with low CO2 concentrations. Maximal productivity, however, was promptly recovered when optimal cultivation conditions were reinstated. These results exhibit an apparent opportunity to employ the Algadisk photobioreactor at large scale for microalgae biomass production if diffusion does not limit the CO2 supply.

  6. Biosorption of heavy metals in a photo-rotating biological contactor--a batch process study.

    Science.gov (United States)

    Orandi, Sanaz; Lewis, David M

    2013-06-01

    Metal removal potential of indigenous mining microorganisms from acid mine drainage (AMD) has been well recognised in situ at mine sites. However, their removal capacity requires to be investigated for AMD treatment. In the reported study, the capacity of an indigenous AMD microbial consortium dominated with Klebsormidium sp., immobilised in a photo-rotating biological contactor (PRBC), was investigated for removing various elements from a multi-ion synthetic AMD. The synthetic AMD was composed of major (Cu, Mn, Mg, Zn, Ca, Na, Ni) and trace elements (Fe, Al, Cr, Co, Se, Ag, Mo) at initial concentrations of 2 to 100 mg/L and 0.005 to 1 mg/L, respectively. The PRBC was operated for two 7-day batch periods under pH conditions of 3 and 5. The maximum removal was observed after 3 and 6 days at pH 3 and 5, respectively. Daily water analysis data demonstrated the ability of the algal-microbial biofilm to remove an overall average of 25-40 % of the major elements at pH 3 in the order of Na > Cu > Ca > Mg > Mn > Ni > Zn, whereas a higher removal (35-50 %) was observed at pH 5 in the order of Cu > Mn > Mg > Ca > Ni > Zn > Na. The removal efficiency of the system for trace elements varied extensively between 3 and 80 % at the both pH conditions. The batch data results demonstrated the ability for indigenous AMD algal-microbial biofilm for removing a variety of elements from AMD in a PRBC. The work presents the potential for further development and scale-up to use PBRC inoculated with AMD microorganisms at mine sites for first or secondary AMD treatment.

  7. Ammonia removal in the carbon contactor of a hybrid membrane process.

    Science.gov (United States)

    Stoquart, Céline; Servais, Pierre; Barbeau, Benoit

    2014-12-15

    The hybrid membrane process (HMP) coupling powdered activated carbon (PAC) and low-pressure membrane filtration is emerging as a promising new option to remove dissolved contaminants from drinking water. Yet, defining optimal HMP operating conditions has not been confirmed. In this study, ammonia removal occurring in the PAC contactor of an HMP was simulated at lab-scale. Kinetics were monitored using three PAC concentrations (1-5-10 g L(-1)), three PAC ages (0-10-60 days), two temperatures (7-22 °C), in ambient influent condition (100 μg N-NH4 L(-1)) as well as with a simulated peak pollution scenario (1000 μg N-NH4L(-1)). The following conclusions were drawn: i) Using a colonized PAC in the HMP is essential to reach complete ammonia removal, ii) an older PAC offers a higher resilience to temperature decrease as well as lower operating costs; ii) PAC concentration inside the HMP reactor is not a key operating parameter as under the conditions tested, PAC colonization was not limited by the available surface; iii) ammonia flux limited biomass growth and iv) hydraulic retention time was a critical parameter. In the case of a peak pollution, the process was most probably phosphate-limited but a mixed adsorption/nitrification still allowed reaching a 50% ammonia removal. Finally, a kinetic model based on these experiments is proposed to predict ammonia removal occurring in the PAC reactor of the HMP. The model determines the relative importance of the adsorption and biological oxidation of ammonia on colonized PAC, and demonstrates the combined role of nitrification and residual adsorption capacity of colonized PAC. PMID:25459222

  8. Separative power of an optimised concurrent gas centrifuge

    Energy Technology Data Exchange (ETDEWEB)

    Bogovalov, Sergey; Boman, Vladimir [National Research Nuclear University (MEPHI), Moscow (Russian Federation)

    2016-06-15

    The problem of separation of isotopes in a concurrent gas centrifuge is solved analytically for an arbitrary binary mixture of isotopes. The separative power of the optimised concurrent gas centrifuges for the uranium isotopes equals to δU = 12.7 (V/700 m/s)2(300 K/T)(L/1 m) kg·SWU/yr, where L and V are the length and linear velocity of the rotor of the gas centrifuge and T is the temperature. This equation agrees well with the empirically determined separative power of optimised counter-current gas centrifuges.

  9. [Design and optimization of a centrifugal pump for CPCR].

    Science.gov (United States)

    Pei, J; Tan, X; Chen, K; Li, X

    2000-06-01

    Requirements for an optimal centrifugal pump, the vital component in the equipment for cardiopulmonary cerebral resuscitation(CPCR), have been presented. The performance of the Sarns centrifugal pump (Sarns, Inc./3M, Ann arbor, MI, U.S.A) was tested. The preliminarily optimized model for CPCR was designed according to the requirements of CPCR and to the comparison and analysis of several clinically available centrifugal pumps. The preliminary tests using the centrifugal pump made in our laboratory(Type CPCR-I) have confirmed the design and the optimization.

  10. Effects of centrifugation on gonadal and adrenocortical steroids in rats

    Science.gov (United States)

    Kakihana, R.; Butte, J. C.

    1980-01-01

    Many endocrine systems are sensitive to external changes in the environment. Both the pituitary adrenal and pituitary gonadal systems are affected by stress including centrifugation stress. The effect of centrifugation on the pituitary gonadal and pituitary adrenocortical systems was examined by measuring the gonadal and adrenal steroids in the plasma and brain following different duration and intensity of centrifugation stress in rats. Two studies were completed and the results are presented. The second study was carried out to describe the developmental changes of brain, plasma and testicular testosterone and dihydrotestosterone in Sprague Dawley rats so that the effect of centrifugation stress on the pituitary gonadal syatem could be better evaluated in future studies.

  11. Computer simulation for centrifugal mold filling of precision titanium castings

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    Computer simulation codes were developed based on a proposed mathematical model for centrifugal mold filling processes and previous computer software for 3D mold filling and solidification of castings (CASM-3D for Windows). Sample simulations were implemented for mold filling processes of precision titanium castings under gravity and different centrifugal casting techniques. The computation results show that the alloy melt has a much stronger mold filling ability for thin section castings under a centrifugal force field than that only under the gravity. A "return back" mold filling manner is showed to be a reasonable technique for centrifugal casting processes, especially for thin section precision castings.

  12. EM Task 9 - Centrifugal membrane filtration

    International Nuclear Information System (INIS)

    The overall project consists of several integrated research phases related to the applicability, continued development, demonstration, and commercialization of the SpinTek centrifugal membrane filtration process. Work performed during this reporting period consisted of Phase 2 evaluation of the SpinTek centrifugal membrane filtration technology and Phase 3, Technology Partnering. During Phase 1 testing conducted at the EERC using the SpinTek ST-IIL unit operating on a surrogate tank waste, a solids cake developed on the membrane surface. The solids cake was observed where linear membrane velocities were less than 17.5 ft/s and reduced the unobstructed membrane surface area up to 25%, reducing overall filtration performance. The primary goal of the Phase 2 research effort was to enhance filtration performance through the development and testing of alternative turbulence promoter designs. The turbulence promoters were designed to generate a shear force across the entire membrane surface sufficient to maintain a self-cleaning membrane capability and improve filtration efficiency and long-term performance. Specific Phase 2 research activities included the following: System modifications to accommodate an 11-in.-diameter, two-disk rotating membrane assembly; Development and fabrication of alternative turbulence promoter designs; Testing and evaluation of the existing and alternative turbulence promoters under selected operating conditions using a statistically designed test matrix; and Data reduction and analysis; The objective of Phase 3 research was to demonstrate the effectiveness of SpinTek's centrifugal membrane filtration as a pretreatment to remove suspended solids from a liquid waste upstream of 3M's WWL cartridge technology for the selective removal of technetium (Tc)

  13. Rotational spectroscopy with an optical centrifuge

    CERN Document Server

    Korobenko, Aleksey; Hepburn, John W; Milner, Valery

    2013-01-01

    We demonstrate a new spectroscopic method for studying electronic transitions in molecules with extremely broad range of angular momentum. We employ an optical centrifuge to create narrow rotational wave packets in the ground electronic state of $^{16}$O$_2$. Using the technique of resonance-enhanced multi-photon ionization, we record the spectrum of multiple ro-vibrational transitions between $X^3\\Sigma_{g}^{-}$ and $C^3\\Pi_{g}$ electronic manifolds of oxygen. Direct control of rotational excitation, extending to rotational quantum numbers as high as $N\\gtrsim 120$, enables us to interpret the complex structure of rotational spectra of $C^3\\Pi_{g}$ beyond thermally accessible levels.

  14. Gas centrifuge bibliography 1980-1982

    International Nuclear Information System (INIS)

    A bibliography, with abstract, is presented of the gas centrifuge literature published from 1980 to 1982 inclusive. It supplements PG Information Series 25 (CA), BNFL Information Series 15 (CA) and BNFL Information Series 23 (CA), which covered the periods 1895 to 1970, 1970 to 1974, and 1975 to 1979 respectively. After bibliographies and books and pamphlets, the main list is arranged chronologically under the headings, Reports, Journal articles, and Conference papers. Items omitted from the earlier bibliographies or received too late for inclusion in this, have been listed separately. There are author, report number and subject indexes. (U.K.)

  15. DESIGN PARAMETERS OF CENTRIFUGAL COMPRESSOR INDUCER

    Directory of Open Access Journals (Sweden)

    Saim KOÇAK

    1998-03-01

    Full Text Available Design characteristics of centrifugal compressor impellers working with compressible fluids are analyzed, and the design parameters of inducer are defined. The effects of incidence, deviation and deflection angles, relative eddy, rotating stall and Mach number are investigated. The relation between minimum relative Mach number of inducer and flow angle is investigated and it is observed that the minimum Mach number occurs for flow angle values between -680 and -520 . In the design, the effect of a 100 difference in flow angle is found to be less than 1 % on minimum relative Mach number.

  16. Rotordynamic Forces on Centrifugal Pump Impellers

    OpenAIRE

    Franz, R.; Arndt, N.; Caughey, T. K.; Brennen, C. E.; Acosta, A.J

    1987-01-01

    The asymmetric flow around an impeller in a volute exerts a force upon the impeller. To study the rotordynamic force on an impeller which is vibrating around its machine axis of rotation, the impeller, mounted on a dynamometer, is made to whirl in a circular orbit within the volute. The measured force is expressed as the sum of a steady radial force and an unsteady force due to the eccentric motion of the impeller. These forces were measured in separate tests on a centrifugal pump with rad...

  17. THERMODYNAMIC DESIGN OF CENTRIFUGAL COMPRESSOR FOR TURBOCHARGER

    OpenAIRE

    Sonawane Shubham*, Sondkar Pratik, Qasim Siddiqui, Phirke Indraneel, Prof. R. P. Kakde

    2016-01-01

    The purpose of a turbocharger is to increase the power output of an engine by supplying compressed air to the engine intake manifold so that fuel can be burnt efficiently. In this work, thermodynamic design of a high pressure ratio centrifugal compressor, for 75 kW class engines, was carried out. A pressure ratio of 2.8 was considered with a compressor rotational speed of 60,000 RPM. The compressor was designed for vane less diffuser. The impeller designs were obtained using ci...

  18. Design and Prototyping of Micro Centrifugal Compressor

    Institute of Scientific and Technical Information of China (English)

    Shimpei Mizuki; Gaku Minorikawa; Toshiyuki Hirano; Yuichiro Asaga; Naoki Yamaguchi; Yutaka Ohta; Eisuke Outa

    2003-01-01

    In order to establish the design methodology of ultra micro centrifugal compressor, which is the most important component of ultra micro gas turbine unit, a 10 times of the final target size model was designed, prototyped and tested. The problems to be solved for downsizing were examined and 2-dimensional impeller was chosen as the first model due to its productivity. The conventional 1D prediction method, CFD and the inverse design were attempted. The prototyped compressor was driven by using a turbocharger and the performance characteristics were measured.

  19. Impeller blade design method for centrifugal compressors

    Science.gov (United States)

    Jansen, W.; Kirschner, A. M.

    1974-01-01

    The design of a centrifugal impeller with blades that are aerodynamically efficient, easy to manufacture, and mechanically sound is discussed. The blade design method described here satisfies the first two criteria and with a judicious choice of certain variables will also satisfy stress considerations. The blade shape is generated by specifying surface velocity distributions and consists of straight-line elements that connect points at hub and shroud. The method may be used to design radially elemented and backward-swept blades. The background, a brief account of the theory, and a sample design are described.

  20. Theory and experiments on centrifuge cratering

    Science.gov (United States)

    Schmidt, R. M.; Holsapple, K. A.

    1980-01-01

    Centrifuge experimental techniques provide possibilities for laboratory simulation of ground motion and cratering effects due to explosive loadings. The results of a similarity analysis for the thermomechanical response of a continuum show that increased gravity is a necessary condition for subscale testing when identical materials for both model and prototype are being used. The general similarity requirements for this type of subscale testing are examined both theoretically and experimentally. The similarity analysis is used to derive the necessary and sufficient requirements due to the general balance and jump equations and gives relations among all the scale factors for size, density, stress, body forces, internal energy, heat supply, heat conduction, heat of detonation, and time. Additional constraints due to specific choices of material constitutive equations are evaluated separately. The class of constitutive equations that add no further requirements is identified. For this class of materials, direct simulation of large-scale cratering events at small scale on the centrifuge is possible and independent of the actual constitutive equations. For a rate-independent soil it is shown that a small experiment at gravity g and energy E is similar to a large event at 1 G but with energy equal to g3E. Consequently, experiments at 500 G with 8 grams of explosives can be used to simulate a kiloton in the field. A series of centrifuge experiments was performed to validate the derived similarity requirements and to determine the practicality of applying the technique to dry granular soils having little or no cohesion. Ten shots using Ottawa sand at various gravities confirmed reproducibility of results in the centrifuge environment, provided information on particle size effects, and demonstrated the applicability of the derived similitude requirements. These experiments used 0.5-4 grams of pentaerythritol-tetranitrate (PETN) and 1.7 grams of lead-azide explosives. They

  1. Design of an Annular Disc Subject to Thermomechanical Loading

    Directory of Open Access Journals (Sweden)

    Sergei Alexandrov

    2012-01-01

    Full Text Available Two solutions to design a thin annular disc of variable thickness subject to thermomechanical loading are proposed. It is assumed that the thickness of the disc is everywhere sufficiently small for the stresses to be averaged through the thickness. The state of stress is plane. The initiation of plastic yielding is controlled by Mises yield criterion. The design criterion for one of the solutions proposed requires that the distribution of stresses is uniform over the entire disc. In this case there is a relation between optimal values of the loading parameters at the final stage. The specific shape of the disc corresponds to each pair of such parameters. The other solution is obtained under the additional requirement that the distribution of strains is uniform. This solution exists for the disc of constant thickness at specific values of the loading parameters.

  2. Study of spiral flow generated through an annular slit

    Science.gov (United States)

    Kim, Tae Hun; Matsuo, Shigeru; Setoguchi, Toshiaki; Kim, Heuy-Dong

    2005-06-01

    The effect of pressurized air inlets in the reservoir upstream of the annular slit on characteristics of the axial and tangential velocity components is investigated numerically, and the mechanism of occurrence of spiral nozzle flow is clarified. In simulations, Unified Platform for Aerospace Computational Simulation (UPACS) is used. The governing equations under consideration are the unsteady compressible Navier - Stokes. A second-order finite volume scheme with MUSCL (Roe scheme) is used to discretize the spatial derivatives, and a second order-central difference scheme for the viscous terms, and a MFGS (Matrix Free Gauss Seidel) is employed for time integration. Spalart-Allmaras model was used as a turbulence model. The results obtained are compared with velocity distributions in the experiment measured by the two-component fiber optic laser Doppler velocimeter system. The existence of discrete pressurized air inlets that leads to the occurrence of asymmetrical characteristics is a very important factor for the formation of spiral flow.

  3. Study of Spiral Flow Generated through an Annular Slit

    Institute of Scientific and Technical Information of China (English)

    Tae Hun KIM; Shigeru MATSUO; Toshiaki SETOGUCHI; Heuy-Dong KIM

    2005-01-01

    @@ The effect of pressurized air inlets in the reservoir upstream of the annular slit on characteristics of the axial and tangential velocity components is investigated numerically, and the mechanism of occurrence of spiral nozzle flow is clarified. In simulations, Unified Platform for Aerospace Computational Simulation (UPACS) is used. The governing equations under consideration are the unsteady compressible Navier - Stokes. A second-order finite volume scheme with MUSCL (Roe scheme) is used to discretize the spatial derivatives, and a second order-central difference scheme for the viscous terms, and a MFGS (Matrix Free Gauss Seidel) is employed for time integration. Spalart-Allmaras model was used as a turbulence model. The results obtained are compared with velocity distributions in the experiment measured by the two-component fiber optic laser Doppler velocimeter system. The existence of discrete pressurized air inlets that leads to the occurrence of asymmetrical characteristics is a very important factor for the formation of spiral flow.

  4. Liquid transfer and entrainment correlation for droplet-annular flow

    International Nuclear Information System (INIS)

    A correlation for the amount of entrained liquid in annular flow has been developed from a simple model and experimental data. There are basically two different regions of entrainment, namely, the entrance and quasi-equilibrium regions. The correlation for the equilibrium region is expressed in terms of the dimensionless gas flux, diameter, cand total liquid Reynolds number. The entrance effect is taken into account by an exponential relaxation function. It has been shown that this new model can satisfactorily correlate wide ranges of experimental data for water. Furthermore, the necessary distance for the development of entrainment is identified. These correlations, therefore, can supply accurate information on entrainment which has not been available previously

  5. Development of annular targets for {sup 99}MO production.

    Energy Technology Data Exchange (ETDEWEB)

    Conner, C.; Lewandowski, E. F.; Snelgrove, J. L.; Liberatore, M. W.; Walker, D. E.; Wiencek, T. C.; McGann, D. J.; Hofman, G. L.; Vandegrift, G. F.

    1999-09-30

    The new annular target performed well during irradiation. The target is inexpensive and provides good heat transfer during irradiation. Based on these and previous tests, we conclude that targets with zirconium tubes and either nickel-plated or zinc-plated foils work well. We proved that we could use aluminum target tubes, which are much cheaper and easier to work with than the zirconium tubes. In aluminum target tubes nickel-plated fission-recoil barriers work well and prevent bonding of the foil to the new target tubes during irradiation. Also, zinc-plated and aluminum-foil barriers appear promising in anodized aluminum tubes. Additional tests are anticipated to address such issues as fission-recoil barrier thickness and uranium foil composition. Overall, however, the target was successful and will provide an inexpensive, efficient way to irradiate LEU metal foil for the production of {sup 99}Mo.

  6. An in-house developed annular bright field detection system

    International Nuclear Information System (INIS)

    Annular bright field (ABF) detectors have been developed in the last few years allowing the direct imaging of low-Z atoms from oxygen down to hydrogen. These types of detectors are now available as standard attachments for the latest generation of top-end electron microscopes. However these systems cannot always be installed in previous generation microscopes. In this paper we report the preliminary results of an in-house implementation of a ABF detection system on a CEOS aberration corrected JEOL 2200FS STEM. This has been obtained by exploiting the standard BF detector coupled with a high vacuum compatible, X-ray tight and retractable shadowing mechanism. This results in the acquisition of near zero-angle scattered electrons with inner collection semi-angle from 2.0 mrad to 23 mrad and outer semi-angle in the range from 3.0 mrad to 35 mrad. The characteristics and performances of this ABF detection system are discussed

  7. Two-phase flow instabilities in a vertical annular channel

    Energy Technology Data Exchange (ETDEWEB)

    Babelli, I.; Nair, S.; Ishii, M. [Purdue Univ., West Lafayette, IN (United States)

    1995-09-01

    An experimental test facility was built to study two-phase flow instabilities in vertical annular channel with emphasis on downward flow under low pressure and low flow conditions. The specific geometry of the test section is similar to the fuel-target sub-channel of the Savannah River Site (SRS) Mark 22 fuel assembly. Critical Heat Flux (CHF) was observed following flow excursion and flow reversal in the test section. Density wave instability was not recorded in this series of experimental runs. The results of this experimental study show that flow excursion is the dominant instability mode under low flow, low pressure, and down flow conditions. The onset of instability data are plotted on the subcooling-Zuber (phase change) numbers stability plane.

  8. Mathematical model for multicomponent separations on the continuous annular chromatograph

    Energy Technology Data Exchange (ETDEWEB)

    Bratzler, R.L.; Begovich, J.M.

    1980-12-01

    A model for multicomponent separations on ion exchange columns has been adapted for use in studying the performance of the continuous annular chromatograph. The model accurately predicts solute peak positions in the column effluent and qualitatively predicts trends in solute effluent resolution as a function of increasing bandwidth of the solute feed pulse. The major virtues of the model are its simplicity in terms of the calculations involved and the fact that it incorporates the nonlinear solute-resin binding isotherms common in many ion exchange separations. Because dispersion effects are not accounted for in the model, discrepancies exist between the shapes of the effluent peaks predicted by the model and those determined experimentally.

  9. A Novel Design of Magnetorheological Damper with Annular Radial Channel

    Directory of Open Access Journals (Sweden)

    Shisha Zhu

    2016-01-01

    Full Text Available With the development of automotive vibration technology, the semiactive suspension system with adjustable damping force and high reliability is taken seriously. The magnetorheological damper (MRD that applies intelligent material (magnetorheological fluid is the key element of this system. It can achieve a continuous and adjustable damping and then reaches the purpose of comfort. In order to improve the damping effect of MRD, this paper presents a MRD, which has magnetorheological (MR effect along annular radial channel. The paper completely designs the structure and magnetic circuit of MRD. Based on the theory of electromagnetism and MR fluid dynamics, the paper analyzes and tests the external characteristics of the MRD by the MATLAB/Simulink and the vibration experiment. The results compared with ordinary MRD reveal that the damping force obviously increases and has wide adjustable range, thus verifying the reasonableness of the damper design.

  10. The Southern Annular Mode: a comparison of indices

    Directory of Open Access Journals (Sweden)

    M. Ho

    2011-08-01

    Full Text Available The Southern Annular Mode (SAM has been identified as a climate mechanism with potentially significant impacts on the Australian hydroclimate. However, despite the identification of some relationships between SAM and Australia's hydroclimate, the association has not been extensively explored or robustly quantified. Further complicating the situation is the existence of numerous indices (or methods by which SAM has been approximated. In this paper, the various SAM definitions and indices are reviewed and the similarities and discrepancies are discussed, along with the strengths and weaknesses of each index development approach. Further, the sensitivity of the relationship between SAM and Australian rainfall on choice of SAM index is quantified and recommendations are given as to the most appropriate index to use when assessing the impacts of the SAM on Australia's hydroclimate.

  11. Damping of cylindrical structures subject to annular flow

    International Nuclear Information System (INIS)

    In previous reports theoretical methods have been described for estimating the aerodynamic forces acting on cylinders vibrating laterally when surrounded by an annulus carrying high velocity gas. For a certain restricted set of geometries it is possible to predict whether a particular structure is stable or unstable and to determine the level of aerodynamic damping positive or negative due to the presence of the gas. This report describes experimental work which validates the computer program in which the theoretical methods are embodied; in particular the damping, inertial and decentralising forces acting on a cylinder in an annulus are measured and compared with theory over a range of frequencies from 0 to 25 Hz, and of Reynolds numbers from zero to 104. In addition a summary of simple relationships is provided which can be used to provide credible initial estimates of both the positive and negative damping of cylinders in a range of annular geometries. (author)

  12. Fluxons in long and annular intrinsic Josephson junction stacks

    Science.gov (United States)

    Clauss, T.; Oehmichen, V.; Mößle, M.; Müller, A.; Weber, A.; Koelle, D.; Kleiner, R.

    2002-12-01

    A promising approach towards a THz oscillator based on intrinsic Josephson junctions in high-temperature superconductors is based on the collective motion of Josephson fluxons, which are predicted to form various configurations ranging from a triangular to a quadratic lattice. Not only for this reason, but certainly also for the sake of basic physics, several experimental and theoretical investigations have been done on the subject of collective fluxon dynamics in stacked intrinsic Josephson junctions. In this paper we will present some experimental results on the fluxon dynamics of long intrinsic Josephson junction stacks made of Bi2Sr2CaCu2O8. The stacks were formed either in an open or in an annular geometry, and clear resonant fluxon modes were observed. Experiments discussed include measurements of current-voltage characteristics in external magnetic fields and in external microwave fields.

  13. Aerodynamic performance of an annular classical airfoil cascade

    Science.gov (United States)

    Bergsten, D. E.; Stauter, R. C.; Fleeter, S.

    1983-01-01

    Results are presented for a series of experiments that were performed in a large-scale subsonic annular cascade facility that was specifically designed to provide three-dimensional aerodynamic data for the verification of numerical-calculation codes. In particular, the detailed three-dimensional aerodynamic performance of a classical flat-plate airfoil cascade is determined for angles of incidence of 0, 5, and 10 deg. The resulting data are analyzed and are correlated with predictions obtained from NASA's MERIDL and TSONIC numerical programs. It is found that: (1) at 0 and 5 deg, the airfoil surface data show a good correlation with the predictions; (2) at 10 deg, the data are in fair agreement with the numerical predictions; and (3) the two-dimensional Gaussian similarity relationship is appropriate for the wake velocity profiles in the mid-span region of the airfoil.

  14. Investigation of a low NOx full-scale annular combustor

    Science.gov (United States)

    1982-01-01

    An atmospheric test program was conducted to evaluate a low NOx annular combustor concept suitable for a supersonic, high-altitude aircraft application. The lean premixed combustor, known as the vortex air blast (VAB) concept, was tested as a 22.0-cm diameter model in the early development phases to arrive at basic design and performance criteria. Final demonstration testing was carried out on a full scale combustor of 0.66-m diameter. Variable geometry dilution ports were incorporated to allow operation of the combustor across the range of conditions between idle (T(in) = 422 K, T(out) = 917 K) and cruise (T(in) = 833 K, T(out) - 1778 K). Test results show that the design could meet the program NOx goal of 1.0 g NO2/kg fuel at a one-atmospheric simulated cruise condition.

  15. Intermittent Flow of Granular Matter in an Annular Geometry

    Science.gov (United States)

    Brzinski, Ted; Daniels, Karen E.

    Granular solids can be subjected to a finite stress below which the response is elastic. Above this yield stress, however, the material fails catastrophically, undergoing a rapid plastic deformation. In the case of a monotonically increasing stress the material exhibits a characteristic stick-slip response. We investigate the statistics of this intermittent failure in an annular shear geometry, driven with a linear-ramp torque in order to generate the stick-slip behavior. The apparatus is designed to allow visual access to particle trajectories and inter-particle forces (through the use of photoelastic materials). Additionally, twelve piezoelectric sensors at the outer wall measure acoustic emissions due to the plastic deformation of the material. We vary volume fraction, and use both fixed and deformable boundaries. We measure how the distribution of slip size and duration are related to the bulk properties of the packing, and compare to systems with similar governing statistics.

  16. Mathematical model for multicomponent separations on the continuous annular chromatograph

    International Nuclear Information System (INIS)

    A model for multicomponent separations on ion exchange columns has been adapted for use in studying the performance of the continuous annular chromatograph. The model accurately predicts solute peak positions in the column effluent and qualitatively predicts trends in solute effluent resolution as a function of increasing bandwidth of the solute feed pulse. The major virtues of the model are its simplicity in terms of the calculations involved and the fact that it incorporates the nonlinear solute-resin binding isotherms common in many ion exchange separations. Because dispersion effects are not accounted for in the model, discrepancies exist between the shapes of the effluent peaks predicted by the model and those determined experimentally

  17. Annular elastolytic giant cell granuloma of conjunctiva: A case report

    Directory of Open Access Journals (Sweden)

    Karabi Konar

    2014-01-01

    Full Text Available Annular elastolytic giant cell granuloma is a condition characterized histologically by damaged elastic fibers associated with preponderance of giant cells along with absence of necrobiosis, lipid, mucin, and pallisading granuloma. It usually occurs on sun-damaged skin and hence the previous name actinic granuloma. A similar process occurs on the conjunctiva. Over the past three decades only four cases of conjunctival actinic granuloma have been documented. All the previous patients were females with lesions in nasal or temporal bulbar conjunctiva varying 2-3 mm in size. We report a male patient aged 70 years presenting with a 14 mm × 7 mm fleshy mass on right lower bulbar conjunctiva. Clinical differential diagnoses were lymphoma, squamous cell carcinoma in situ and amyloidosis. Surgical excision followed by histopathology confirmed it to be a case of actinic granuloma. This is the first case of isolated conjunctival actinic granuloma of such a large size reported from India.

  18. Periocular granuloma annulare: a case report and review of literature.

    Science.gov (United States)

    Chiang, Katherine; Bhalla, Rohan; Mesinkovska, Natasha A; Piliang, Melissa P; Tamburro, Joan E

    2014-01-01

    Granuloma annulare (GA) is a granulomatous dermatosis that rarely presents on the face and is extremely uncommon in the periocular region. We report our experience with the presentation and management of GA lesions on the eyelids of a 17-year-old girl. We performed a review of published literature and identified 13 cases of pediatric periocular GA. One additional case was identified upon review of all pediatric GA cases at the Cleveland Clinic Foundation. Review of these cases suggests that periocular GA is a benign condition that spontaneously regresses within a few months. GA nodules have a predilection for the upper eyelids. A greater incidence is noted in African American children. Awareness of the self-resolving nature of this condition can prevent unnecessary surgical excisions in affected children. PMID:23551387

  19. Performance of annular flow sterilizer irradiated by a germicidal lamp

    Energy Technology Data Exchange (ETDEWEB)

    Sugawara, T.; Yoneya, M.; Ohashi, H. (Akita Univ. (Japan))

    1981-10-01

    Theoretical and experimental studies were conducted on the UV-inactivation characteristics of Bacillus subtilis spores in an annular-flow sterilizer irradiated by a germicidal lamp located at the center of the inner tube. Experimental results for sterilizer performance in laminar spore-suspension flow were well simulated dynamically and statically by theoretical considerations which incorporated multi-targets with single-hit model for the UV-inactivation kinetic and the diffuse light model for the angle characteristic of lamp, along with due attention to the parabolic velocity distribution and the negligible diffusion of spores. Scale on the outside wall of the inner tube was checked by the use of a cylindrical chemical actinometer. Calculated examples elucidate the reason why careful inspection is needed of UV-inactivation kinetics, angle characteristics of lamp, and fluid mixing to evaluate performance of actual flow UV sterilizers at high extent of inactivation up to the order of 99.999%.

  20. Magnetically guided free surface annular NaK flow experiment

    International Nuclear Information System (INIS)

    In order to gain basic information on the magnetically guided liquid metal Li waterfall type blanket concept for ICF reactors and liquid metal Li free surface flow for FMIT type accelerator target, an experimental study was conducted by using LINAK (NaK: 50 l, Ar: 0-0.3 MPa) device. A 45 mm O.D. and 25 mm I.D. annular free jet of NaK, which flowed downwards coaxially through a superconducting magnet (2.7 Tmax, B=0.38 T at the nozzle exit), was formed in vacuum chamber and at the nozzle exit where magnetic flux density B was divergent. The experiment covered ranges of U=0.5-2.5 m/s and B=0-0.38 T at the nozzle exit. Photographic and VTR observations were made on the behavior of outer surface of annular flow. The results are summarized as follows. (1) When B=0 T, the downward flow was rather convergent due to the surface tension. (2) By applying B, the flow became divergent like a cone shell and more stable. The divergent half angle increased with intensifying B. (3) The experimental results on the flow divergence agreed fairly well with the numerical analysis which took into account the MHD force, the surface tension and the gravitational force. (4) No growth of outer surface disturbance occurred within an attained maximum divergent half angle of 8deg or less. The results are considered to be encouraging for applying to ICF blanket and FMIT type target. (author)

  1. Experimental study on the separation of CO{sub 2} from flue gas using hollow fiber membrane contactors without wetting

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Shui-ping; Fang, Meng-Xiang; Zhang, Wei-Feng; Luo, Zhong-Yang; Cen, Ke-Fa [State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027 (China); Wang, Shu-Yuan; Xu, Zhi-Kang [Institute of Polymer Science, Zhejiang University, Hangzhou 310027 (China)

    2007-05-15

    Experiments on CO{sub 2} removal from flue gas using polypropylene (PP) hollow fiber membrane contactors were conducted in this study. Absorbents including aqueous potassium glycinate (PG) solution, aqueous solutions of monoethanolamine (MEA) and methyldiethanolamine (MDEA) were used to absorb CO{sub 2} in the experiments. Based on the wetting experimental results, aqueous PG solution can offer a higher surface tension than water, aqueous MEA and MDEA solutions. Aqueous PG solution has a lower potential of membrane wetting after a continuously steady operation for 40 h to maintain CO{sub 2} removal efficiency of about 90%. Under moderate operating conditions, effects of the temperature, flow rate, and concentration of absorbents, and the flow rate of flue gas as well as the volumetric concentration of carbon dioxide in the flue gas on the mass transfer rate of CO{sub 2} were studied on a pilot-scale test facility. Unlike conventional absorbents, the mass transfer decreases with an increasing liquid temperature when using aqueous PG solution. Results show that CO{sub 2} removal efficiency was above 90% and the mass transfer rate was above 2.0 mol/(m{sup 2} h) using the PG aqueous solution. It indicates that the hollow fiber membrane contactor has a great potential in the area of CO{sub 2} separation from flue gas when absorbent's concentration and liquid-gas pressure difference are designed elaborately. (author)

  2. Preparation of Calcium Carbonate Nanoparticles with a Continuous Gas-liquid Membrane Contactor:Particles Morphology and Membrane Fouling

    Institute of Scientific and Technical Information of China (English)

    JIA Zhiqian; CHANG Qing; QIN Jin; MAMAT Aynur

    2013-01-01

    Nanosized calcium carbonate particles were prepared with a continuous gas-liquid membrane contactor.The effects of Ca(OH)2 concentration,CO2 pressure and liquid flow velocity on the particles morphology,pressure drop and membrane fouling were studied.With rising Ca(OH)2 concentrations,the average size of the particles increased.The effects of Ca(OH)2 concentration and CO2 pressure on particles were not apparent under the experimental conditions.When the Ca(OH)2 concentration and liquid flow velocity were high,or the CO2 pressure was low,the fouling on the membrane external surface at the contactor entrance was serious due to liquid leakage,whereas the fouling was slight at exit.The fouling on the membrane inner-surface at entrance was apparent due to adsorption of raw materials.The membrane can be recovered by washing with dilute hydrochloric acid and reused for at least 6 times without performance deterioration.

  3. Numerical Simulation of the Laval Annular Mechanical Foam Breaker for Foam Drilling

    Directory of Open Access Journals (Sweden)

    Pin Lu Cao

    2013-12-01

    Full Text Available The Computational Fluid Dynamics (CFD code, Fluent, is employed to simulate the flow phenomena inside the annular foam breaker in order to improve its performance. The numerical simulation results show that the value and the distribution of the negative pressure are very important for the annular foam breaker. The design of the Laval nozzle not only can increase the fluid velocity, but also can reduce the pressure value from -30.2 to -50.3 kPa compared with the common annular nozzle foam breaker. In order to improve the range of the internal negative pressure, the two-stage Laval annular foam breaker is designed in this study. The analysis results show the distance between the two annular slit have greatly influence on its performance. There is a small overlap area between the two negative pressure zones generated by the two annular slits. The smaller the value distance is, the larger the overlap zone is. When the value of the distance decreases to 50 mm, the minimum negative pressure can be reduced to approximately -65.5 kPa. Meanwhile, the range of the internal negative pressure is larger than the single Laval annular foam breaker, which is benefit to break foam.

  4. Hollow fiber membrane contactors for post-combustion CO2 capture: a scale-up study from laboratory to pilot plant

    NARCIS (Netherlands)

    Chabanon, E.; Kimball, E.; Favre, E.; Lorain, O.; Goetheer, E.L.V.; Ferre, D.; Gomez, A.; Broutin, P.

    2013-01-01

    Membrane contactors have been proposed for decades as a way to achieve intensified mass transfer processes. Post-combustion CO2 capture by absorption into a chemical solvent is one of the currently most intensively investigated topics in this area. Numerous studies have already been reported, unfort

  5. Centrifugally Stimulated Exospheric Ion Escape at Mercury

    Science.gov (United States)

    Delcourt, Dominique; Seki, K.; Terada, N.; Moore, Thomas E.

    2012-01-01

    We investigate the transport of ions in the low-altitude magnetosphere magnetosphere of Mercury. We show that, because of small spatial scales, the centrifugal effect due to curvature of the E B drift paths can lead to significant particle energization in the parallel direction. We demonstrate that because of this effect, ions with initial speed smaller than the escape speed such as those produced via thermal desorption can overcome gravity and escape into the magnetosphere. The escape route of this low-energy exosphere originating material is largely controlled by the magnetospheric convection rate. This escape route spreads over a narrower range of altitudes when the convection rate increases. Bulk transport of low-energy planetary material thus occurs within a limited region of space once moderate magnetospheric convection is established. These results suggest that, via release of material otherwise gravitationally trapped, the E B related centrifugal acceleration is an important mechanism for the net supply of plasma to the magnetosphere of Mercury.

  6. Postcardiotomy centrifugal assist: a single surgeon's experience.

    Science.gov (United States)

    Curtis, Jack J; McKenney-Knox, Charlotte A; Wagner-Mann, Colette C

    2002-11-01

    Because of the infrequent application of cardiac assist devices for postcardiotomy heart failure, most published reports include the results of learning curves from multiple surgeons. Between October 1986 and June 2001, a single surgeon used 35 Sarns Centrifugal Pumps as ventricular assist devices in 21 patients with severe hemodynamic compromise after open heart surgery (0.88% incidence). Patients' ages ranged from 39 to 77 (mean, 59.6 years). Three patients required right ventricular assist devices, 4 left ventricular assist devices, and 14 had biventricular assist devices. For all, the indication for application was inability to wean from cardiopulmonary bypass despite multiple inotropes and intraaortic balloon pumping. All were expected to be intraoperative deaths without further mechanical assistance. Patients were assisted from 2 to 434 h (median, 48 h). Fifteen patients (71.4%) were weaned from device(s), and 11 patients (52.4%) were hospital survivors. Actuarial survival in those dismissed from the hospital was 78% at 5 years and 39% at 10 years. Patients facing certain demise after cardiac surgery can be salvaged with temporary centrifugal mechanical assist. Results are competitive with that achieved with more sophisticated devices. Hospital survivors enjoy reasonable longevity.

  7. PARTICLE DISTRIBUTION IN CENTRIFUGAL ACCELERATING FIELDS

    Institute of Scientific and Technical Information of China (English)

    Yu Sirong; Zhang Xinping; He Zhenming; Liu Yaohui

    2003-01-01

    Based on continuum theory and moving law of particles, a model is presented to obtain gradient distribution of particles in centrifugal accelerating field, by which the particle distribution in gradient composite material can be predicted. The simulation shows with increases in rotating time, four regions gradually appear from the internal periphery to the external one, they are free region, transition region, steady region and surface reinforced region,and the latest three regions are defined as a rich region. Finally, the steady region disappears, and the rich region only includes transition region and surface reinforced region. The influences of centrifugal acceleration coefficient G,primary volume fraction (0,pouring temperature (p and density difference between the particle and the metal matrix on particles gradient distribution are studied in detail. The results of the theoretical analysis agree with experiment ones. Both of analysis and experiment results indicate that with the increase in G and (p, the particle distribution becomes more centralized and the consistence of particle in the surface periphery becomes larger.

  8. Some aversive characteristics of centrifugally generated gravity.

    Science.gov (United States)

    Altman, F.

    1973-01-01

    The effective weight of rats was manipulated by centrifugation. Two effective weight levels were obtained. In three escape avoidance conditions a lever press produced a change from a base level of 2.1 g to a response level of 1.1 g. In a punishment condition a response produced a change from a 1.1 g level to a 2.1 g level and in an extinction condition responses had no effect on the 2.1 g effective weight level present. All changes took 30 sec and were maintained for an additional 10 sec before a return to base level was initiated. When responses occurred closer together than the 40 sec, they delayed the return to base level by 40 sec. This 40 sec interval is referred to as response-contingent-time. The response rate and amount of response-contingent-time served as the data. The results confirmed previous data that centrifugation is aversive. The results are interpreted as indicating that the aversiveness is attributable to the increase in effective weight, and that rats can discriminate the different angular velocity-radius of rotation combinations used.

  9. Virtual Prototyping Technology of AC Contactor%交流接触器虚拟样机设计技术

    Institute of Scientific and Technical Information of China (English)

    何晓燕; 许志红

    2016-01-01

    采用虚拟样机技术,建立全面反映交流接触器动态特性的三维虚拟样机模型,模型包含完整触头系统、铁心系统及连接部件,从而考虑结构特点对其运动特性的影响。引入Ansys/LS-DYNA 动力学分析软件,采用基于连续介质力学的有限元法考虑机构之间的非线性接触、碰撞问题及弹性材料的形变作用,计算接触器动作过程中的触头弹跳情况。通过三维可视化界面得到触头、铁心等运动部件位移、速度随时间变化情况,对接触器动态特性进行直观地分析。通过交流接触器虚拟样机模型的仿真,从机械动力学角度,分析触头系统闭合速度和触头弹簧初压力、金属簧片物理特性及触头表面摩擦系数对触头弹跳的影响。交流接触器的三维虚拟样机设计对其结构优化设计具有良好的理论依据和实用价值。%With virtual prototyping technology, this paper establishes the 3D virtual prototyping model of AC contactor including the whole contact system, core system and connecting parts. It reflects the real dynamic characteristics of AC contactor affected by the structure. Based on the finite method of continuum mechanics, the nonlinear contact, collision problem and elastic material deformation have been taken into account in the dynamic analysis software Ansys/LS-DYNA. Contact bounce in the process of contactor action is simulated. Moreover, by 3D visualization window, the displacement and velocity of movable contact and core changing over time are obtained and the dynamic characteristics of contactor are analyzed visually. In addition, the influence of closure speed, pre force of spring, properties of reed and friction coefficient of contact on contact bounce has been analyzed from the view of mechanical dynamics. The 3D virtual prototype design of AC contactor provides theoretical basis for its structure optimization design and has high practical value.

  10. Performance Characteristics ofAC Contactor During Voltage Sag%晃电故障下交流接触器的工作特性分析

    Institute of Scientific and Technical Information of China (English)

    林抒毅; 许志红

    2011-01-01

    电磁式交流接触器是一种应用广泛的低压电器产品,当晃电故障发生时,交流接触器可能因为不稳定电压而频繁接通或分断,对系统造成很大的影响。论文以CJ20.63A交流接触器为研究对象,建立考虑触头运动情况的电磁机构吸合过程、吸持阶段以及释放过程的磁路动态计算方程,并通过实验验证了模型的正确性。针对不同的合闸相角和工作状态进行仿真,分析了发生晃电故障时电压下降幅度、晃电故障持续时间、晃电故障发生时刻及电压相角变化对接触器工作特性的影响。结果表明,吸合阶段的晃电影响与吸合时问有直接关系,吸合以后的晃电故障影响存在临界%Electromagnetic contactor is a kind of widely used electric product. When the voltage drops suddenly, the contactor will be open or closed frequently, and the circuit will be influenced seriously. Based on the research of CJ20-63A contactor dynamic equations were established during closing, cIosed and opening processes; the movement process of the moving contact and the bounce of the contacts were considered at the meantime. The experimental data shows the model is correct. Simulations were carried out with respect to different working states and various closing phase angles. Influences of the range, duration and occurrence time of voltage drop, and the variation of voltage phases on performance characteristics of contactors were analyzed; the result indicates that the influences of voltage sag on the contactor are related to the closing time directly in the closing process; and a critical time value should be considered after the contactor is closed. This research provides the basic for the further study on the intelligent AC contactor with anti-voltage sag.

  11. On the Motion of an Annular Film in Microgravity Gas-Liquid Flow

    Science.gov (United States)

    McQuillen, John B.

    2002-01-01

    Three flow regimes have been identified for gas-liquid flow in a microgravity environment: Bubble, Slug, and Annular. For the slug and annular flow regimes, the behavior observed in vertical upflow in normal gravity is similar to microgravity flow with a thin, symmetrical annular film wetting the tube wall. However, the motion and behavior of this film is significantly different between the normal and low gravity cases. Specifically, the liquid film will slow and come to a stop during low frequency wave motion or slugging. In normal gravity vertical upflow, the film has been observed to slow, stop, and actually reverse direction until it meets the next slug or wave.

  12. Characterization of annular two-phase gas-liquid flows in microgravity

    Science.gov (United States)

    Bousman, W. Scott; Mcquillen, John B.

    1994-01-01

    A series of two-phase gas-liquid flow experiments were developed to study annular flows in microgravity using the NASA Lewis Learjet. A test section was built to measure the liquid film thickness around the perimeter of the tube permitting the three dimensional nature of the gas-liquid interface to be observed. A second test section was used to measure the film thickness, pressure drop and wall shear stress in annular microgravity two-phase flows. Three liquids were studied to determine the effects of liquid viscosity and surface tension. The result of this study provide insight into the wave characteristics, pressure drop and droplet entrainment in microgravity annular flows.

  13. Burnout in the boiling of water and freon-113 on tubes with annular fins

    International Nuclear Information System (INIS)

    This paper presents the results of numerical calculations of burnout heat flux associated with the boiling of Freon-113 and water on an annular fin of constant thickness which have been approximated by simple analytical relations. These are used to calculate the critical burnout parameters of tubes with an annular fin assembly. The calculated data may be used for the analysis of tubes with an annular fin assembly over a wide range of variation of the thermophysical properties of the material and geometrical parameters of the fin assembly

  14. V5 AND V10 CONTACTOR TESTING WITH THE NEXT GENERATION (CSSX) SOLVENT FOR THE SAVANNAH RIVER SITE INTEGRATED SALT DISPOSITION PROCESS

    Energy Technology Data Exchange (ETDEWEB)

    Restivo, M.; Peters, T.; Pierce, R.; Fondeur, F.; Steeper, T.; Williams, M.; Giddings, B.; Hickman, B.; Fink, S.

    2012-01-17

    program to test the full size strip (V5) and extraction (V10) centrifugal contactors and the associated strip and extraction effluent coalescers to determine the hydraulic and mass transfer characteristics with the NGS. The test program evaluated the amount of organic carryover and the droplet size of the carryover phases using several analytical methods. Provisions were also made to enable an evaluation of coalescer performance. Stage efficiency and mass distribution ratios were determined using Cs mass transfer measurements. Using 20 millimolar (mM) extractant (instead of 50 mM), the nominal D(Cs) measured was 16.0-17.5. The data indicate that equilibrium is achieved rapidly and maintained throughout sampling. The data showed good stage efficiency for extraction (Tests 1A-1D), ranging from 98.2% for Test 1A to 90.5% for Test 1D. No statistically-significant differences were noted for operations at 12 gpm aqueous flow when compared with either 4 gpm or 8 gpm of aqueous flow. The stage efficiencies equal or exceed those previously measured using the baseline CSSX solvent system. The nominal target for scrub Cs distribution values are {approx}1.0-2.5. The first scrub test yielded an average scrub value of 1.21 and the second scrub test produced an average value of 0.78. Both values are considered acceptable. Stage efficiency was not calculated for the scrub tests. For stripping behavior, six tests were completed in a manner to represent the first strip stage. For three tests at the baseline flow ratios (O:A of 3.75:1) but at different total flow rates, the D(Cs) values were all similar at {approx}0.052. Similar behavior was observed for two tests performed at an O:A ratio of 7:1 instead of 3.75:1. The data for the baseline strip tests exhibited acceptable stage efficiency, ranging from 82.0% for low flow to 89-90% for medium and high flow. The difference in efficiency may be attributable to the low volume in the contactor housing at lower flow rates. The concentrations of

  15. V5 AND V10 CONTACTOR TESTING WITH THE NEXT GENERATION (CSSX) SOLVENT FOR THE SAVANNAH RIVER SITE INTEGRATED SALT DISPOSITION PROCESS

    Energy Technology Data Exchange (ETDEWEB)

    Restivo, M.; Peters, T.; Pierce, R.; Fondeur, F.; Steeper, T.; Williams, M.; Giddings, B.; Hickman, B.; Fink, S.

    2012-01-17

    program to test the full size strip (V5) and extraction (V10) centrifugal contactors and the associated strip and extraction effluent coalescers to determine the hydraulic and mass transfer characteristics with the NGS. The test program evaluated the amount of organic carryover and the droplet size of the carryover phases using several analytical methods. Provisions were also made to enable an evaluation of coalescer performance. Stage efficiency and mass distribution ratios were determined using Cs mass transfer measurements. Using 20 millimolar (mM) extractant (instead of 50 mM), the nominal D(Cs) measured was 16.0-17.5. The data indicate that equilibrium is achieved rapidly and maintained throughout sampling. The data showed good stage efficiency for extraction (Tests 1A-1D), ranging from 98.2% for Test 1A to 90.5% for Test 1D. No statistically-significant differences were noted for operations at 12 gpm aqueous flow when compared with either 4 gpm or 8 gpm of aqueous flow. The stage efficiencies equal or exceed those previously measured using the baseline CSSX solvent system. The nominal target for scrub Cs distribution values are {approx}1.0-2.5. The first scrub test yielded an average scrub value of 1.21 and the second scrub test produced an average value of 0.78. Both values are considered acceptable. Stage efficiency was not calculated for the scrub tests. For stripping behavior, six tests were completed in a manner to represent the first strip stage. For three tests at the baseline flow ratios (O:A of 3.75:1) but at different total flow rates, the D(Cs) values were all similar at {approx}0.052. Similar behavior was observed for two tests performed at an O:A ratio of 7:1 instead of 3.75:1. The data for the baseline strip tests exhibited acceptable stage efficiency, ranging from 82.0% for low flow to 89-90% for medium and high flow. The difference in efficiency may be attributable to the low volume in the contactor housing at lower flow rates. The concentrations of

  16. High Efficiency Centrifugal Compressor for Rotorcraft Applications

    Science.gov (United States)

    Medic, Gorazd; Sharma, Om P.; Jongwook, Joo; Hardin, Larry W.; McCormick, Duane C.; Cousins, William T.; Lurie, Elizabeth A.; Shabbir, Aamir; Holley, Brian M.; Van Slooten, Paul R.

    2014-01-01

    The report "High Efficiency Centrifugal Compressor for Rotorcraft Applications" documents the work conducted at UTRC under the NRA Contract NNC08CB03C, with cost share 2/3 NASA, and 1/3 UTRC, that has been extended to 4.5 years. The purpose of this effort was to identify key technical barriers to advancing the state-of-the-art of small centrifugal compressor stages; to delineate the measurements required to provide insight into the flow physics of the technical barriers; to design, fabricate, install, and test a state-of-the-art research compressor that is representative of the rear stage of an axial-centrifugal aero-engine; and to acquire detailed aerodynamic performance and research quality data to clarify flow physics and to establish detailed data sets for future application. The design activity centered on meeting the goal set outlined in the NASA solicitation-the design target was to increase efficiency at higher work factor, while also reducing the maximum diameter of the stage. To fit within the existing Small Engine Components Test Facility at NASA Glenn Research Center (GRC) and to facilitate component re-use, certain key design parameters were fixed by UTRC, including impeller tip diameter, impeller rotational speed, and impeller inlet hub and shroud radii. This report describes the design effort of the High Efficiency Centrifugal Compressor stage (HECC) and delineation of measurements, fabrication of the compressor, and the initial tests that were performed. A new High-Efficiency Centrifugal Compressor stage with a very challenging reduction in radius ratio was successfully designed, fabricated and installed at GRC. The testing was successful, with no mechanical problems and the running clearances were achieved without impeller rubs. Overall, measured pressure ratio of 4.68, work factor of 0.81, and at design exit corrected flow rate of 3 lbm/s met the target requirements. Polytropic efficiency of 85.5 percent and stall margin of 7.5 percent were

  17. Development of a miniature Taylor-Couette extractor column for nuclear solvent extraction

    International Nuclear Information System (INIS)

    Miniature annular centrifugal contactors are nearly perfect for shielded hot-cell applications during flowsheet evaluation but these contactors require complex maintenance of electrical drive-motors during radioactive experiments. To reduce the number of electrical drives in the shielded cell, an indigenous design of miniature Taylor Couette (TC) mixing based countercurrent differential extraction column has been developed. In this paper, results of mass transfer experiments for an indigenously developed TC column with 30% TBP/aqueous nitric acid solutions are reported. The developed device worked perfectly in counter-current differential mode and demonstrated equivalence to multiple-extraction stages while working with a single electrical drive. The developed TC unit demonstrated operation with a reduced efficiency without flooding even in absence of rotor rotation. This observation is a vital step towards designing of robust contactors, which do not flood during temporary power failure or failure of drive mechanism. (author)

  18. Separative power of an optimised concurrent gas centrifuge

    CERN Document Server

    Bogovalov, S V

    2015-01-01

    The problem of separation of uranium isotopes in a concurrent gas centrifuge is solved analytically. Separative power of the optimized concurrent gas centrifuges equals to $\\delta U=12.7(V/700~{\\rm m/s})^2 (300 ~{\\rm K}/T)L, ~{\\rm kg ~SWU/yr}$, where $L$ and $V$ are the length and linear velocity of the rotor of the gas centrifuge, $T$ is the temperature. This formula well agrees with an empirical separative power of counter current gas centrifuges. The optimal value of the separative power is not unique on the plane $(p_w,v_z)$, where $p_w$ is pressure at the wall of the rotor and $v_z$ is axial velocity of the gas. This value is constant on a line defined by the equation $p_wv_z=constant$. Equations defining the mass flux and the electric power necessary to support the rotation of the gas centrifuge are obtained.

  19. Centrifugal acceleration of plasma in pulsar magnetosphere

    Indian Academy of Sciences (India)

    R T Gangadhara; V Krishna

    2003-12-01

    We present a relativistic model for the centrifugal acceleration of plasma bunches and the coherent radio emission in pulsar magnetosphere. We find that rotation broadens the width of leading component compared to the width of trailing component. We explain this difference in the component widths using the nested cone emission geometry. We estimate the effect of pulsar spin on the Stokes parameters, and find that the inclination between the rotation and magnetic axes can introduce an asymmetry in the circular polarization of the conal components. We analyse the single pulse polarization data of PSR B0329+54 at 606 MHz, and find that in its conal components, one sense of circular polarization dominates in the leading component while the other sense dominates in the trailing component. Our simulation shows that changing the sign of the impact parameter changes the sense of circular polarization as well as the swing of polarization angle.

  20. [Hemodynamic analysis of a centrifugal blood pump].

    Science.gov (United States)

    Wang, Yang; Yang, Ming; Xu, Zihao; Zhuang, Xiaoqi; Li, Qilei; Xu, Liang

    2015-01-01

    This paper built the mathematical model of a centrifugal blood pump, which was designed by ourselves, combined it with that of the human cardiovascular system and simulated the coupling system using Matlab. Then we set up the experiment platform, linked the blood pump to mock human cardiovascular system in case of three-stage heart failure, and measured aortic pressure and flow under different speed. The comparison between experiment results and simulation results not only indicates the coupling model is correct and the blood pump works well, but also shows that with the increase of blood pump speed, the pulsation of aortic pressure and flow will be reduced, this situation will affect the structure and function of blood vessels.

  1. Stability of centrifugal pump characteristic curve

    OpenAIRE

    Chmatil, Ľuboš

    2011-01-01

    Předložená diplomová práce obsahuje teoretický rozbor charakteristik odstředíveho čerpadla, podmínky stability Y(Q) charakteristiky, výpočet charakteristiky ßč(ns), úpravy vedúce k stabilizaci spirálního telesa a oběžného kola, návrh spirály, obežného kola a následný výpočet v programe Fluent. This master's thesis includes theoretical analysis of characteristics of a centrifugal pump, conditions of stability of Y(Q) characteristic, calculation of characteristics ßč(ns), modifications leadi...

  2. Rotordynamic forces on centrifugal pump impellers

    Science.gov (United States)

    Franz, R.; Arndt, N.; Caughey, T. K.; Brennen, C. E.; Acosta, A. J.

    1987-01-01

    The asymmetric flow around an impeller in a volute exerts a force upon the impeller. To study the rotordynamic force on an impeller which is vibrating around its machine axis of rotation, the impeller, mounted on a dynamometer, is made to whirl in a circular orbit within the volute. The measured force is expressed as the sum of a steady radial force and an unsteady force due to the eccentric motion of the impeller. These forces were measured in separate tests on a centrifugal pump with radically increased shroud clearance, a two-dimensional impeller, and an impeller with an inducer, the impeller of the HPOTP (High Pressure Oxygen Turbopump) of the SSME (Space Shuttle Main Engine). In each case, a destabilizing force was observed over a region of positive whirl.

  3. [Hemodynamic analysis of a centrifugal blood pump].

    Science.gov (United States)

    Wang, Yang; Yang, Ming; Xu, Zihao; Zhuang, Xiaoqi; Li, Qilei; Xu, Liang

    2015-01-01

    This paper built the mathematical model of a centrifugal blood pump, which was designed by ourselves, combined it with that of the human cardiovascular system and simulated the coupling system using Matlab. Then we set up the experiment platform, linked the blood pump to mock human cardiovascular system in case of three-stage heart failure, and measured aortic pressure and flow under different speed. The comparison between experiment results and simulation results not only indicates the coupling model is correct and the blood pump works well, but also shows that with the increase of blood pump speed, the pulsation of aortic pressure and flow will be reduced, this situation will affect the structure and function of blood vessels. PMID:26027287

  4. Potential commercial applications of centrifuge technology

    International Nuclear Information System (INIS)

    As part of an effort to prevent the loss of and maximize the use of unique developments of the centrifuge program, this document identifies and briefly describes unclassified technologies potentially available for transfer. In addition, this document presents a preliminary plan for action needed to carry out the transfer activity. Continuing efforts will provide additional descriptions of technologies which have applications that are not as apparent or as obvious as those presented here. Declassification of some of the program information, now classified as restricted data, would permit the descriptions of additional technologies which have significant commercial potential. The following are major areas of technology where transfer opportunities exist: biomedical; separation; motors and control systems; materials; vacuum; dynamics and balancing; and diagnostics and instrumentation

  5. Design of radial phononic crystal using annular soft material with low-frequency resonant elastic structures

    Science.gov (United States)

    Gao, Nansha; Wu, Jiu Hui; Yu, Lie; Xin, Hang

    2016-10-01

    Using FEM, we theoretically study the vibration properties of radial phononic crystal (RPC) with annular soft material. The band structures, transmission spectra, and displacement fields of eigenmode are given to estimate the starting and cut-off frequency of band gaps. Numerical calculation results show that RPC with annular soft material can yield low-frequency band gaps below 350 Hz. Annular soft material decreases equivalent stiffness of the whole structure effectively, and makes corresponding band gaps move to the lower frequency range. Physical mechanism behind band gaps is the coupling effect between long or traveling wave in plate matrix and the vibrations of corrugations. By changing geometrical dimensions of plate thickness e, the length of silicone rubber h2, and the corrugation width b, we can control the location and width of the first band gap. These research conclusions of RPC structure with annular soft material can potentially be applied to optimize band gaps, generate filters, and design acoustic devices.

  6. Entropy Analysis for Non-Newtonian Fluid Flow in Annular Pipe: Constant Viscosity Case

    Directory of Open Access Journals (Sweden)

    Mehmet Pakdemirli

    2004-06-01

    Full Text Available Abstract: In the present study, non-Newtonian flow in annular pipe is considered. The analytical solution for velocity and temperature fields is presented while entropy generation due to fluid friction and heat transfer is formulated. The third grade fluid with constant properties is accommodated in the analysis. It is found that reducing non-Newtonian parameter increases maximum velocity magnitude and maximum temperature in the annular pipe. Total entropy generation number attains high values in the region close to the inner wall of the annular pipe, which becomes significant for low non-Newtonian parameters. Increasing Brinkman number enhances entropy generation number, particularly in the region close to the annular pipe inner wall.

  7. Biofilm Community Dynamics in Bench-Scale Annular Reactors Simulating Arrestment of Chloraminated Drinking Water Nitrification

    Science.gov (United States)

    Annular reactors (ARs) were used to study biofilm community succession and provide an ecological insight during nitrification arrestment through simultaneously increasing monochloramine (NH2Cl) and chlorine to nitrogen mass ratios, resulting in four operational periods (I to IV)....

  8. Ultra-Wide-Band Microstrip Concentric Annular Ring Antenna for Wireless Communications

    Directory of Open Access Journals (Sweden)

    Salima Azzaz-Rahmani

    2012-01-01

    Full Text Available In this paper, a new design technique for bandwidth enhancement of concentric microstrip annular ring slot antennas is presented. Using this technique, an Ultra-Wide-Band antenna is designed with simulated bandwidth of 111.29%.

  9. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area...... is less than that of a normal valve. It is suggested that the ability to implant Top Hat valves having greater size, relative to standard intra-annular valves, may currently be under-utilized. Further, there has been some concern that Top Hat implantation can cause obstruction of the coronary ostia....... This study evaluates the authors' clinical experience with Top Hat supra-annular aortic valve size selection, and the technical aspects of implantation. METHODS: Between January 1999 and October 2005, a total of 251 consecutive patients underwent 252 aortic valve replacements with Top Hat supra...

  10. An iterative method for the solution of nonlinear systems using the Faber polynomials for annular sectors

    Energy Technology Data Exchange (ETDEWEB)

    Myers, N.J. [Univ. of Durham (United Kingdom)

    1994-12-31

    The author gives a hybrid method for the iterative solution of linear systems of equations Ax = b, where the matrix (A) is nonsingular, sparse and nonsymmetric. As in a method developed by Starke and Varga the method begins with a number of steps of the Arnoldi method to produce some information on the location of the spectrum of A. This method then switches to an iterative method based on the Faber polynomials for an annular sector placed around these eigenvalue estimates. The Faber polynomials for an annular sector are used because, firstly an annular sector can easily be placed around any eigenvalue estimates bounded away from zero, and secondly the Faber polynomials are known analytically for an annular sector. Finally the author gives three numerical examples, two of which allow comparison with Starke and Varga`s results. The third is an example of a matrix for which many iterative methods would fall, but this method converges.

  11. A Novel Fabrication Method for Functionally Graded Materials under Centrifugal Force: The Centrifugal Mixed-Powder Method

    Directory of Open Access Journals (Sweden)

    Eri Miura-Fujiwara

    2009-12-01

    Full Text Available One of the fabrication methods for functionally graded materials (FGMs is a centrifugal solid-particle method, which is an application of the centrifugal casting technique. However, it is the difficult to fabricate FGMs containing nano-particles by the centrifugal solid-particle method. Recently, we proposed a novel fabrication method, which we have named the centrifugal mixed-powder method, by which we can obtain FGMs containing nano-particles. Using this processing method, Cu-based FGMs containing SiC particles and Al-based FGMs containing TiO2 nano-particles on their surfaces have been fabricated. In this article, the microstructure and mechanical property of Cu/SiC and Al/TiO2 FGMs, fabricated by the centrifugal mixed-powder method are reviewed.

  12. Multiphase flow modeling in centrifugal partition chromatography.

    Science.gov (United States)

    Adelmann, S; Schwienheer, C; Schembecker, G

    2011-09-01

    The separation efficiency in Centrifugal Partition Chromatography (CPC) depends on selection of a suitable biphasic solvent system (distribution ratio, selectivity factor, sample solubility) and is influenced by hydrodynamics in the chambers. Especially the stationary phase retention, the interfacial area for mass transfer and the flow pattern (backmixing) are important parameters. Their relationship with physical properties, operating parameters and chamber geometry is not completely understood and predictions are hardly possible. Experimental flow visualization is expensive and two-dimensional only. Therefore we simulated the flow pattern using a volume-of-fluid (VOF) method, which was implemented in OpenFOAM®. For the three-dimensional simulation of a rotating FCPC®-chamber, gravitational centrifugal and Coriolis forces were added to the conservation equation. For experimental validation the flow pattern of different solvent systems was visualized with an optical measurement system. The amount of mobile phase in a chamber was calculated from gray scale values of videos recorded by an image processing routine in ImageJ®. To visualize the flow of the stationary phase polyethylene particles were used to perform a qualitative particle image velocimetry (PIV) analysis. We found a good agreement between flow patterns and velocity profiles of experiments and simulations. By using the model we found that increasing the chamber depth leads to higher specific interfacial area. Additionally a circular flow in the stationary phase was identified that lowers the interfacial area because it pushes the jet of mobile phase to the chamber wall. The Coriolis force alone gives the impulse for this behavior. As a result the model is easier to handle than experiments and allows 3D prediction of hydrodynamics in the chamber. Additionally it can be used for optimizing geometry and operating parameters for given physical properties of solvent systems. PMID:21324465

  13. A straight path centrifugal blood pump concept in the Capiox centrifugal pump.

    Science.gov (United States)

    Kijima, T; Oshiyama, H; Horiuchi, K; Nogawa, A; Hamasaki, H; Amano, N; Nojiri, C; Fukasawa, H; Akutsu, T

    1993-07-01

    This article describes comparative studies of a newly developed "straight path" centrifugal pump (Capiox centrifugal pump) targeted for open-heart surgery and circulatory support. A unique straight path design of the rotor was very effective in reducing the pump's rotational speed and prime volume. This pump was evaluated for hydraulics, hemolysis, depriming characteristics, cavitation, and heat generation. Two commercially available centrifugal pumps, the Biomedicus cone-type pump and the Sarns 3M impeller-type pump, were used as controls. The new pump required the lowest pump speed to produce the same flow rates under the same pressure loads and demonstrated the lowest hemolysis and the lowest temperature rise with the outlet clamped. The air volume required to deprime the new pump was one-third to one-half that for the other pumps, and no sign of cavitation was observed even if a small amount of air was introduced to the pump inlet under a negative pressure of 200 mm Hg.

  14. CENTRIFUGAL PUMP AND SHAFT SEALING MEANS

    Science.gov (United States)

    Rushing, F.C.

    1960-09-01

    A description is given of sealing means between a hollow rotatable shaft and a stationary member surrounding the shaft which defines therewith a sealing space of annular cross-section, comprising a plurality of axially spaced rings held against seats by ring springs which serve to subdivide the sealing space- into a plurality of zones. Process gas introduced into the hollow shaft through a port communicating with a centrally located zone which iu turn communicates with a bore in the sleeve, is removed from the shaft through a second port communicating with an adjacent central zone and discharged through a second bore. A sealant gas is supplied to an end zone under a pressure sufficient to cause it to flow axially into adjacent zones and then maintained at a lower pressure than either the sealant gas source or the process gas inlet zone, preventing the sealant gas from entering the shaft and allowing gases leaking into the sealant gas to be withdrawn and led to a separator.

  15. A research on the mechanisms of transition from annular flow in two-phase pipeline flow

    International Nuclear Information System (INIS)

    Various kinds mechanisms of transitions from two-phase annular flow in tubes were studied and modelled, and the affection factors on the transitions were also discussed. Some mathematical equations and transition criteria for every mechanisms presented were derived, and an unified general criterion for the annular flow transitions in whole range of pipe inclinations was recommended. The boundaries predicted show good agreement with the air-water two-phase experimental data

  16. Asymmetric Vibration of Polar Orthotropic Annular Circular Plates of Quadratically Varying Thickness with Same Boundary Conditions

    OpenAIRE

    Bhardwaj, N; Gupta, A. P.; Choong, K.K.

    2008-01-01

    In the present paper, asymmetric vibration of polar orthotropic annular circular plates of quadratically varying thickness resting on Winkler elastic foundation is studied by using boundary characteristic orthonormal polynomials in Rayleigh-Ritz method. Convergence of the results is tested and comparison is made with results already available in the existing literature. Numerical results for the first ten frequencies for various values of parameters describing width of annular plate, thicknes...

  17. Large Eddy Simulation of ignition in an annular multi-injector combustor

    Science.gov (United States)

    Vicquelin, Ronan; Philip, Maxime; Boileau, Matthieu; Schmitt, Thomas; Bourgoin, Jean-François; Durox, Daniel; Candel, Sébastien

    2013-11-01

    The present work deals with validating the LES methodology for transient ignition simulations, and in particular elucidating the mechanisms that control the light round sequence in a laboratory annular combustor, representative of many practical industrial systems. The simulation benefits from the unique experimental database built at EM2C on a fully transparent annular chamber equipped with 16 premixed swirled injectors. The F-TACLES combustion model is used for its ability to properly represent the flame propagation.

  18. A simple analytical model to study and control azimuthal instabilities in annular combustion chambers

    OpenAIRE

    Parmentier, Jean-François; Salas, Pablo; Wolf, Pierre; Staffelbach, Gabriel; Nicoud, Franck; Poinsot, Thierry

    2012-01-01

    This study describes a simple analytical method to compute the azimuthal modes appearing in annular combustion chambers and help analyzing experimental, acoustic and large eddy simulation (LES) data obtained in these combustion chambers. It is based on a one-dimensional zero Mach number formulation where N burners are connected to a single annular chamber. A manipulation of the corresponding acoustic equations in this configuration leads to a simple dispersion relation which can be solved by ...

  19. The numerical solution of flow field of short-annular combustion chamber

    Science.gov (United States)

    Xu, H.; Ning, H.

    1986-05-01

    The recirculating flow field of a short-annular combustion chamber has been studied. The body-fitting coordinate system and the 'simple' method combined with a constant viscosity model have been employed to solve the Navier-Stokes equations in a regime containing a complicated curved boundary. The result could provide the theoretical reference for the design and improvement of short-annular combustion chambers.

  20. Non-approximate method for designing annular field of two-mirror concentric system

    Institute of Scientific and Technical Information of China (English)

    Yuanshen Huang; Dongyue Zhu; Baicheng Li; Dawei Zhang; Zhengji Ni; Songlin Zhuang

    2012-01-01

    Annular field aberrations of a three-reflection concentric system, which are composed of two spherical mirrors, are analyzed. An annular field with a high level of aberration correction exists near the position where the principal ray is perpendicular to the object-image plane. Aberrations are determined by the object height and aperture angle. In this letter, the general expression of the system aberration is derived using the geometric method, and the non-approximate design method is proposed to calculate the radii of the annular fields that have minimum aberrations under different aperture angles. The closer to 0.5 (the ratio of the radius of convex mirror to the radius of concave mirror) is, the smaller the system aberration is. The examples analyzed by LABVIEW indicate that the annular field designed by the proposed method has the smallest aberration in a given system.%Annular field aberrations of a three-reflection concentric system,which are composed of two spherical mirrors,are analyzed.An annular field with a high level of aberration correction exists near the position where the principal ray is perpendicular to the object-image plane.Aberrations are determined by the object height and aperture angle.In this letter,the general expression of the system aberration is derived using the geometric method,and the non-approximate design method is proposed to calculate the radii of the annular fields that have minimum aberrations under different aperture angles.The closer to 0.5 (the ratio of the radius of convex mirror to the radius of concave mirror) is,the smaller the system aberration is.The examples analyzed by LABVIEW indicate that the annular field designed by the proposed method has the smallest aberration in a given system.