  1. Annular-ring CMUT arrays for forward-looking IVUS: transducer characterization and imaging.

    Science.gov (United States)

    Degertekin, F Levent; Guldiken, Rasim O; Karaman, Mustafa

    2006-02-01

    In this study, a 64-element, 1.15-mm diameter annular-ring capacitive micromachined ultrasonic transducer (CMUT) array was characterized and used for forward-looking intravascular ultrasound (IVUS) imaging tests. The array was manufactured using low-temperature processes suitable for CMOS electronics integration on a single chip. The measured radiation pattern of a 43 X 140-microm2 array element depicts a 40 degrees view angle for forward-looking imaging around a 15-MHz center frequency in agreement with theoretical models. Pulse-echo measurements show a -10-dB fractional bandwidth of 104% around 17 MHz for wire targets 2.5 mm away from the array in vegetable oil. For imaging and SNR measurements, RF A-scan data sets from various targets were collected using an interconnect scheme forming a 32-element array configuration. An experimental point spread function was obtained and compared with simulated and theoretical array responses, showing good agreement. Therefore, this study demonstrates that annular-ring CMUT arrays fabricated with CMOS-compatible processes are capable of forward-looking IVUS imaging, and the developed modeling tools can be used to design improved IVUS imaging arrays.

  2. Piezoelectric transducer array microspeaker

    KAUST Repository

    Carreno, Armando Arpys Arevalo

    2016-12-19

    In this paper we present the fabrication and characterization of a piezoelectric micro-speaker. The speaker is an array of micro-machined piezoelectric membranes, fabricated on silicon wafer using advanced micro-machining techniques. Each array contains 2n piezoelectric transducer membranes, where “n” is the bit number. Every element of the array has a circular shape structure. The membrane is made out four layers: 300nm of platinum for the bottom electrode, 250nm or lead zirconate titanate (PZT), a top electrode of 300nm and a structural layer of 50

  3. Digital electrostatic acoustic transducer array

    KAUST Repository

    Carreno, Armando Arpys Arevalo

    2016-12-19

    In this paper we present the fabrication and characterization of an array of electrostatic acoustic transducers. The array is micromachined on a silicon wafer using standard micro-machining techniques. Each array contains 2n electrostatic transducer membranes, where “n” is the bit number. Every element of the array has a hexagonal membrane shape structure, which is separated from the substrate by 3µm air gap. The membrane is made out 5µm thick polyimide layer that has a bottom gold electrode on the substrate and a gold top electrode on top of the membrane (250nm). The wafer layout design was diced in nine chips with different array configurations, with variation of the membrane dimensions. The device was tested with 90 V giving and sound output level as high as 35dB, while actuating all the elements at the same time.

  4. Annular array technology for nondestructive turbine inspection. Final report

    International Nuclear Information System (INIS)

    Light, G.M.

    1986-05-01

    The Electric Power Research Institute (EPRI) funded Southwest Research Institute (SwRI) to fabricate and functionally test phased array transducers and an electronic control system with the intent of evaluating the phased array technology for use in the inspection of turbine disks. During this program a 13-element annular array and associated phased array electronics were fabricated and tested and the results of the tests compared to those predicted by theory. The prototype system performed well within the expected limits, and EPRI funded further work to fabricate and test a production unit. The production system consisted of a 25-element annular array and a 25-channel electronics system that had both pulser and receiver delay circuitry. In addition, during the program it was determined that miniaturized hybrid pulser/preamps would be needed to allow the phased array to work over distances exceeding 9.1 meters (30 feet) from the electronics. A circuit developed by SwRI was utilized and found to produce good pulsing capability that did not suffer from impedance mismatch. EPRI also funded (under a separate contract) the fabrication of a small scale static turbine test bed and a full scale dynamic test bed that contained full scale turbine geometries. These test beds were fabricated to enable the production phased array system to be evaluated on turbine disk surfaces. 26 figs

  5. Transducers and arrays for underwater sound

    CERN Document Server

    Butler, John L

    2016-01-01

    This improved and updated second edition covers the theory, development, and design of electro-acoustic transducers for underwater applications. This highly regarded text discusses the basics of piezoelectric and magnetostrictive transducers that are currently being used as well as promising new designs. It presents the basic acoustics as well as the specific acoustics data needed in transducer design and evaluation. A broad range of designs of projectors and hydrophones are described in detail along with methods of modeling, evaluation, and measurement. Analysis of projector and hydrophone transducer arrays, including the effects of mutual radiation impedance and numerical models for elements and arrays, are also covered. The book includes new advances in transducer design and transducer materials and has been completely reorganized to be suitable for use as a textbook, as well as a reference or handbook. The new edition contains updates to the first edition, end-of-chapter exercises, and solutions to select...

  6. Field computation for two-dimensional array transducers with limited diffraction array beams.

    Science.gov (United States)

    Lu, Jian-Yu; Cheng, Jiqi

    2005-10-01

    A method is developed for calculating fields produced with a two-dimensional (2D) array transducer. This method decomposes an arbitrary 2D aperture weighting function into a set of limited diffraction array beams. Using the analytical expressions of limited diffraction beams, arbitrary continuous wave (cw) or pulse wave (pw) fields of 2D arrays can be obtained with a simple superposition of these beams. In addition, this method can be simplified and applied to a 1D array transducer of a finite or infinite elevation height. For beams produced with axially symmetric aperture weighting functions, this method can be reduced to the Fourier-Bessel method studied previously where an annular array transducer can be used. The advantage of the method is that it is accurate and computationally efficient, especially in regions that are not far from the surface of the transducer (near field), where it is important for medical imaging. Both computer simulations and a synthetic array experiment are carried out to verify the method. Results (Bessel beam, focused Gaussian beam, X wave and asymmetric array beams) show that the method is accurate as compared to that using the Rayleigh-Sommerfeld diffraction formula and agrees well with the experiment.

  7. Limited Diffraction Maps for Pulsed Wave Annular Arrays

    DEFF Research Database (Denmark)

    Fox, Paul D.

    2002-01-01

    A procedure is provided for decomposing the linear field of flat pulsed wave annular arrays into an equivalent set of known limited diffraction Bessel beams. Each Bessel beam propagates with known characteristics, enabling good insight into the propagation of annular fields to be obtained...

  8. Capacitive micromachined ultrasonic transducers based on annular cell geometry for air-coupled applications.

    Science.gov (United States)

    Na, Shuai; Chen, Albert I H; Wong, Lawrence L P; Li, Zhenhao; Macecek, Mirek; Yeow, John T W

    2016-09-01

    A novel design of an air-coupled capacitive micromachined ultrasonic transducer (CMUT) with annular cell geometry (annular CMUT) is proposed. Finite element analysis shows that an annular cell has a ratio of average-to-maximum displacement (RAMD) of 0.52-0.58 which is 58-76% higher than that of a conventional circular cell. The increased RAMD leads to a larger volume displacement which results in a 48.4% improved transmit sensitivity and 127.3% improved power intensity. Single-cell annular CMUTs were fabricated with 20-μm silicon plates on 13.7-μm deep and 1.35-mm wide annular cavities using the wafer bonding technique. The measured RAMD of the fabricated CMUTs is 0.54. The resonance frequency was measured to be 94.5kHz at 170-V DC bias. The transmit sensitivity was measured to be 33.83Pa/V and 25.85Pa/V when the CMUT was excited by a continuous wave and a 20-cycle burst, respectively. The receive sensitivity at 170-V DC bias was measured to be 7.7mV/Pa for a 20-cycle burst, and 15.0mV/Pa for a continuous incident wave. The proposed annular CMUT design demonstrates a significant improvement in transmit efficiency, which is an important parameter for air-coupled ultrasonic transducers. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Cymbal and BB underwater transducers and arrays

    Energy Technology Data Exchange (ETDEWEB)

    Newnham, R.E.; Zhang, J.; Alkoy, S.; Meyer, R.; Hughes, W.J.; Hladky-Hennion, A.C.; Cochran, J.; Markley, D. [Materials Research Laboratory, Penn State University, University Park, PA 16802 (United States)

    2002-09-01

    The cymbal is a miniaturized class V flextensional transducer that was developed for use as a shallow water sound projector and receiver. Single elements are characterized by high Q, low efficiency, and medium power output capability. Its low cost and thin profile allow the transducer to be assembled into large flexible arrays. Efforts were made to model both single elements and arrays using the ATILA code and the integral equation formulation (EQI).Millimeter size microprobe hydrophones (BBs) have been designed and fabricated from miniature piezoelectric hollow ceramic spheres for underwater applications such as mapping acoustic fields of projectors, and flow noise sensors for complex underwater structures. Green spheres are prepared from soft lead zirconate titanate powders using a coaxial nozzle slurry process. A compact hydrophone with a radially-poled sphere is investigated using inside and outside electrodes. Characterization of these hydrophones is done through measurement of hydrostatic piezoelectric charge coefficients, free field voltage sensitivities and directivity beam patterns. (orig.)

  10. Highly reliable multisensor array (MSA) smart transducers

    Science.gov (United States)

    Perotti, José; Lucena, Angel; Mackey, Paul; Mata, Carlos; Immer, Christopher

    2006-05-01

    Many developments in the field of multisensor array (MSA) transducers have taken place in the last few years. Advancements in fabrication technology, such as Micro-Electro-Mechanical Systems (MEMS) and nanotechnology, have made implementation of MSA devices a reality. NASA Kennedy Space Center (KSC) has been developing this type of technology because of the increases in safety, reliability, and performance and the reduction in operational and maintenance costs that can be achieved with these devices. To demonstrate the MSA technology benefits, KSC quantified the relationship between the number of sensors (N) and the associated improvement in sensor life and reliability. A software algorithm was developed to monitor and assess the health of each element and the overall MSA. Furthermore, the software algorithm implemented criteria on how these elements would contribute to the MSA-calculated output to ensure required performance. The hypothesis was that a greater number of statistically independent sensor elements would provide a measurable increase in measurement reliability. A computer simulation was created to answer this question. An array of N sensors underwent random failures in the simulation and a life extension factor (LEF equals the percentage of the life of a single sensor) was calculated by the program. When LEF was plotted as a function of N, a quasiexponential behavior was detected with marginal improvement above N = 30. The hypothesis and follow-on simulation results were then corroborated experimentally. An array composed of eight independent pressure sensors was fabricated. To accelerate sensor life cycle and failure and to simulate degradation over time, the MSA was exposed to an environmental tem-perature of 125°C. Every 24 hours, the experiment's environmental temperature was returned to ambient temperature (27°C), and the outputs of all the MSA sensor elements were measured. Once per week, the MSA calibration was verified at five different

  11. Theory and experiment of Fourier-Bessel field calculation and tuning of a pulsed wave annular array

    DEFF Research Database (Denmark)

    Fox, Paul D.; Jiqi, Cheng; Jian-yu, Lu

    2003-01-01

    A one-dimensional (1D) Fourier-Bessel series method for computing and tuning (beamforming) the linear lossless field of flat pulsed wave annular arrays is developed and supported with both numerical simulation and experimental verification. The technique represents a new method for modeling...... and tuning the propagated field by linking the quantized surface pressure profile to a known set of limited diffraction Bessel beams propagating into the medium. This enables derivation of an analytic expression for the field at any point in space and time in terms of the transducer surface pressure profile....... Tuning of the field then also follows by formulating a least-squares design for the transducer surface pressure with respect to a given desired field in space and time. Simulated and experimental results for both field computation and tuning are presented in the context of a 10-ring annular array...

  12. Piezoelectric Nanotube Array for Broadband High-Frequency Ultrasonic Transducer.

    Science.gov (United States)

    Liew, Weng Heng; Yao, Kui; Chen, Shuting; Tay, Francis Eng Hock

    2018-03-01

    Piezoelectric materials are vital in determining ultrasonic transducer and imaging performance as they offer the function for conversion between mechanical and electrical energy. Ultrasonic transducers with high-frequency operation suffer from performance degradation and fabrication difficulty of the demanded piezoelectric materials. Hence, we propose 1-D polymeric piezoelectric nanostructure with controlled nanoscale features to overcome the technical limitations of high-frequency ultrasonic transducers. For the first time, we demonstrate the integration of a well-aligned piezoelectric nanotube array to produce a high-frequency ultrasonic transducer with outstanding performance. We find that nanoconfinement-induced polarization orientation and unique nanotube structure lead to significantly improved piezoelectric and ultrasonic transducing performance over the conventional piezoelectric thin film. A large bandwidth, 126% (-6 dB), is achieved at high center frequency, 108 MHz. Transmission sensitivity of nanotube array is found to be 46% higher than that of the monolithic thin film transducer attributed to the improved electromechanical coupling effectiveness and impedance match. We further demonstrate high-resolution scanning, ultrasonic imaging, and photoacoustic imaging using the obtained nanotube array transducers, which is valuable for biomedical imaging applications in the future.

  13. Aircraft components structural health monitoring using flexible ultrasonic transducer arrays

    Science.gov (United States)

    Liu, W.-L.; Jen, C.-K.; Kobayashi, M.; Mrad, N.

    2011-04-01

    A damage detection capability based on a flexible ultrasonic transducer (FUT) array bonded onto a planar and a curved surface is presented. The FUT array was fabricated on a 75 μm titanium substrate using sol-gel spray technique. Room temperature curable adhesive is used as the bonding agent and ultrasonic couplant between the transducer and the test article. The bonding agent was successfully tested for aircraft environmental temperatures between -80 °C and 100 °C. For a planar test article, selected FUT arrays were able to detect fasteners damage within a planar distance of 176 mm, when used in the pulse-echo mode. Such results illustrate the effectiveness of the developed FUT transducer as compared to commercial 10MHz ultrasonic transducer (UT). These FUT arrays were further demonstrated on a curved test article. Pulse-echo measurements confirmed the reflected echoes from the specimen. Such measurement was not possible with commercial UTs due to the curved nature of the test article and its accessibility, thus demonstrating the suitability and superiority of the developed flexible ultrasonic transducer capability.

  14. Capacitive micromachined ultrasonic transducer arrays as tunable acoustic metamaterials

    International Nuclear Information System (INIS)

    Lani, Shane W.; Sabra, Karim G.; Wasequr Rashid, M.; Hasler, Jennifer; Levent Degertekin, F.

    2014-01-01

    Capacitive Micromachined Ultrasonic Transducers (CMUTs) operating in immersion support dispersive evanescent waves due to the subwavelength periodic structure of electrostatically actuated membranes in the array. Evanescent wave characteristics also depend on the membrane resonance which is modified by the externally applied bias voltage, offering a mechanism to tune the CMUT array as an acoustic metamaterial. The dispersion and tunability characteristics are examined using a computationally efficient, mutual radiation impedance based approach to model a finite-size array and realistic parameters of variation. The simulations are verified, and tunability is demonstrated by experiments on a linear CMUT array operating in 2-12 MHz range

  15. Capacitive micromachined ultrasonic transducer arrays as tunable acoustic metamaterials

    Energy Technology Data Exchange (ETDEWEB)

    Lani, Shane W., E-mail: shane.w.lani@gmail.com, E-mail: karim.sabra@me.gatech.edu, E-mail: levent.degertekin@me.gatech.edu; Sabra, Karim G. [George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 801Ferst Drive, Georgia 30332-0405 (United States); Wasequr Rashid, M.; Hasler, Jennifer [School of Electrical and Computer Engineering, Georgia Institute of Technology, Van Leer Electrical Engineering Building, 777 Atlantic Drive NW, Atlanta, Georgia 30332-0250 (United States); Levent Degertekin, F. [George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 801Ferst Drive, Georgia 30332-0405 (United States); School of Electrical and Computer Engineering, Georgia Institute of Technology, Van Leer Electrical Engineering Building, 777 Atlantic Drive NW, Atlanta, Georgia 30332-0250 (United States)

    2014-02-03

    Capacitive Micromachined Ultrasonic Transducers (CMUTs) operating in immersion support dispersive evanescent waves due to the subwavelength periodic structure of electrostatically actuated membranes in the array. Evanescent wave characteristics also depend on the membrane resonance which is modified by the externally applied bias voltage, offering a mechanism to tune the CMUT array as an acoustic metamaterial. The dispersion and tunability characteristics are examined using a computationally efficient, mutual radiation impedance based approach to model a finite-size array and realistic parameters of variation. The simulations are verified, and tunability is demonstrated by experiments on a linear CMUT array operating in 2-12 MHz range.

  16. Capacitive micromachined ultrasonic transducer arrays as tunable acoustic metamaterials

    Science.gov (United States)

    Lani, Shane W.; Wasequr Rashid, M.; Hasler, Jennifer; Sabra, Karim G.; Levent Degertekin, F.

    2014-02-01

    Capacitive Micromachined Ultrasonic Transducers (CMUTs) operating in immersion support dispersive evanescent waves due to the subwavelength periodic structure of electrostatically actuated membranes in the array. Evanescent wave characteristics also depend on the membrane resonance which is modified by the externally applied bias voltage, offering a mechanism to tune the CMUT array as an acoustic metamaterial. The dispersion and tunability characteristics are examined using a computationally efficient, mutual radiation impedance based approach to model a finite-size array and realistic parameters of variation. The simulations are verified, and tunability is demonstrated by experiments on a linear CMUT array operating in 2-12 MHz range.

  17. Transverse Oscillation Vector Velocity Estimation using a Phased Array Transducer

    DEFF Research Database (Denmark)

    Marcher, Jønne; Pihl, Michael Johannes; Seerup, Gert

    2012-01-01

    greater than 100 mm. Tests at depths of 72 mm and 82 mm with a peak velocity of 0.5 m/s, showed a relative mean bias ~Bvx that varied from 0 % and to 21 % and a relative mean standard deviation ~vx that varied from 18 % and to 51 %. The investigation showed an increasing bias with respect to depth, which......The Transverse Oscillation method has shown its commercial feasibility, providing the user with 2D velocity information. Todays implementation on commercial ultrasound platforms only support linear array transducers and are limited in depth. Extending the implementation to a phased array transducer...... leaves room for optimization. Despite the bias, the method has shown to work and produce reliable results, and 2D velocity estimates are provided within the entire color-box down to a depth of more than 100 mm making vector velocity imaging possible in the entire heart....

  18. High-frequency annular array with coaxial illumination for dual-modality ultrasonic and photoacoustic imaging

    Science.gov (United States)

    Filoux, Erwan; Sampathkumar, Ashwin; Chitnis, Parag V.; Aristizábal, Orlando; Ketterling, Jeffrey A.

    2013-05-01

    This paper presents a combined ultrasound and photoacoustic (PA) imaging (PAI) system used to obtain high-quality, co-registered images of mouse-embryo anatomy and vasculature. High-frequency ultrasound (HFU, >20 MHz) is utilized to obtain high-resolution anatomical images of small animals while PAI provides high-contrast images of the vascular network. The imaging system is based on a 40 MHz, 5-element, 6 mm aperture annular-array transducer with a 800 μm diameter hole through its central element. The transducer was integrated in a cage-plate assembly allowing for a collimated laser beam to pass through the hole so that the optical and acoustic beams were collinear. The assembly was mounted on a two-axis, motorized stage to enable the simultaneous acquisition of co-registered HFU and PA volumetric data. Data were collected from all five elements in receive and a synthetic-focusing algorithm was applied in post-processing to beamform the data and increase the spatial resolution and depth-of-field (DOF) of the HFU and PA images. Phantom measurements showed that the system could achieve high-resolution images (down to 90 μm for HFU and 150 μm for PAI) and a large DOF of >8 mm. Volume renderings of a mouse embryo showed that the scanner allowed for visualizing morphologically precise anatomy of the entire embryo along with corresponding co-registered vasculature. Major head vessels, such as the superior sagittal sinus or rostral vein, were clearly identified as well as limb bud vasculature.

  19. Singulation for imaging ring arrays of capacitive micromachined ultrasonic transducers

    International Nuclear Information System (INIS)

    Chang, Chienliu; Moini, Azadeh; Nikoozadeh, Amin; Sarioglu, Ali Fatih; Apte, Nikhil; Zhuang, Xuefeng; Khuri-Yakub, Butrus T

    2014-01-01

    Singulation of MEMS is a critical step in the transition from wafer-level to die-level devices. As is the case for capacitive micromachined ultrasound transducer (CMUT) ring arrays, an ideal singulation must protect the fragile membranes from the processing environment while maintaining a ring array geometry. The singulation process presented in this paper involves bonding a trench-patterned CMUT wafer onto a support wafer, deep reactive ion etching (DRIE) of the trenches, separating the CMUT wafer from the support wafer and de-tethering the CMUT device from the CMUT wafer. The CMUT arrays fabricated and singulated in this process were ring-shaped arrays, with inner and outer diameters of 5 mm and 10 mm, respectively. The fabricated CMUT ring arrays demonstrate the ability of this method to successfully and safely singulate the ring arrays and is applicable to any arbitrary 2D shaped MEMS device with uspended microstructures, taking advantage of the inherent planar attributes of DRIE. (technical note)

  20. Singulation for imaging ring arrays of capacitive micromachined ultrasonic transducers

    Science.gov (United States)

    Chang, Chienliu; Moini, Azadeh; Nikoozadeh, Amin; Sarioglu, Ali Fatih; Apte, Nikhil; Zhuang, Xuefeng; Khuri-Yakub, Butrus T.

    2014-10-01

    Singulation of MEMS is a critical step in the transition from wafer-level to die-level devices. As is the case for capacitive micromachined ultrasound transducer (CMUT) ring arrays, an ideal singulation must protect the fragile membranes from the processing environment while maintaining a ring array geometry. The singulation process presented in this paper involves bonding a trench-patterned CMUT wafer onto a support wafer, deep reactive ion etching (DRIE) of the trenches, separating the CMUT wafer from the support wafer and de-tethering the CMUT device from the CMUT wafer. The CMUT arrays fabricated and singulated in this process were ring-shaped arrays, with inner and outer diameters of 5 mm and 10 mm, respectively. The fabricated CMUT ring arrays demonstrate the ability of this method to successfully and safely singulate the ring arrays and is applicable to any arbitrary 2D shaped MEMS device with uspended microstructures, taking advantage of the inherent planar attributes of DRIE.

  1. Acoustical cross-talk in row–column addressed 2-D transducer arrays for ultrasound imaging

    DEFF Research Database (Denmark)

    Christiansen, Thomas Lehrmann; Jensen, Jørgen Arendt; Thomsen, Erik Vilain

    2015-01-01

    The acoustical cross-talk in row–column addressed 2-D transducer arrays for volumetric ultrasound imaging is investigated. Experimental results from a 2.7 MHz, λ/2-pitch capacitive micromachined ultrasonic transducer (CMUT) array with 62 rows and 62 columns are presented and analyzed in the frequ......The acoustical cross-talk in row–column addressed 2-D transducer arrays for volumetric ultrasound imaging is investigated. Experimental results from a 2.7 MHz, λ/2-pitch capacitive micromachined ultrasonic transducer (CMUT) array with 62 rows and 62 columns are presented and analyzed...

  2. Volumetric Security Alarm Based on a Spherical Ultrasonic Transducer Array

    Science.gov (United States)

    Sayin, Umut; Scaini, Davide; Arteaga, Daniel

    Most of the existent alarm systems depend on physical or visual contact. The detection area is often limited depending on the type of the transducer, creating blind spots. Our proposition is a truly volumetric alarm system that can detect any movement in the intrusion area, based on monitoring the change over time of the impulse response of the room, which acts as an acoustic footprint. The device depends on an omnidirectional ultrasonic transducer array emitting sweep signals to calculate the impulse response in short intervals. Any change in the room conditions is monitored through a correlation function. The sensitivity of the alarm to different objects and different environments depends on the sweep duration, sweep bandwidth, and sweep interval. Successful detection of intrusions also depends on the size of the monitoring area and requires an adjustment of emitted ultrasound power. Strong air flow affects the performance of the alarm. A method for separating moving objects from strong air flow is devised using an adaptive thresholding on the correlation function involving a series of impulse response measurements. The alarm system can be also used for fire detection since air flow sourced from heating objects differ from random nature of the present air flow. Several measurements are made to test the integrity of the alarm in rooms sizing from 834-2080m3 with irregular geometries and various objects. The proposed system can efficiently detect intrusion whilst adequate emitting power is provided.

  3. Focusing Modeling of OPFC Linear Array Transducer by Using Distributed Point Source Method

    Directory of Open Access Journals (Sweden)

    Ziping Wang

    2014-01-01

    Full Text Available The improvement of ultrasonic phased array detection technology is a major concern of engineering community. Orthotropic piezoelectric fiber composite (OPFC can be constructed to multielement linear array which may be applied conveniently to actuators and sensors. The phased array transducers can generate special directional strong actuator power and high sensitivity for its orthotropic performance. Focusing beam of the linear phased array transducer is obtained simply only by adjusting a parabolic time delay. In this work, the distributed point source method (DPSM is used to model the ultrasonic field. DPSM is a newly developed mesh-free numerical technique that has been developed for solving a variety of engineering problems. This work gives the basic theory of this method and solves the problems from the application of new OPFC phased array transducer. Compared with traditional transducer, the interaction effect of two OPFC linear phased array transducers is also modeled in the same medium, which shows that the pressure beam produced by the new transducer is narrower or more collimated than that produced by the conventional transducer at different angles. DPSM can be used to analyze and optimally design the OPFC linear phased array transducer.

  4. Analysis of the crosstalk in an underwater planar array transducer by the equivalent circuit method

    Science.gov (United States)

    Pyo, Seonghun; Roh, Yongrae

    2017-07-01

    A planar array transducer consists of several transducers arranged on an acoustic window, which causes crosstalk. The crosstalk is a phenomenon in which the acoustic pressure generated by a projector is transferred to adjacent hydrophones through the acoustic window and the transferred pressure generates noise signals in the hydrophones. The performance of the planar array transducer is deteriorated due to this acoustic interaction, which should be minimized for maximum array performance. Analysis of the crosstalk has been carried out with sophisticated numerical methods, which motivated the need to develop a simpler and accurate analysis method. In this work, an equivalent circuit has been developed to analyze the crosstalk level of the planar array transducer, and the validity of the developed method has been verified by comparing the result from the equivalent circuit analysis with that from finite element analysis.

  5. Structural model of standard ultrasonic transducer array developed for FEM analysis of mechanical crosstalk.

    Science.gov (United States)

    Celmer, M; Opieliński, K J; Dopierała, M

    2018-02-01

    One of the reasons of distortions in ultrasonic imaging are crosstalk effects. They can be divided into groups according to the way of their formation. One of them is constituted by mechanical crosstalk, which is propagated by a construction of a multi-element array of piezoelectric transducers. When an individual transducer is excited, mechanical vibrations are transferred to adjacent construction components, thereby stimulating neighboring transducers to an undesired operation. In order to explore ways of the propagation of such vibrations, the authors developed the FEM model of the array of piezoelectric transducers designed for calculations in COMSOL Multiphysics software. Simulations of activating individual transducers and calculated electrical voltages appearing on transducers unstimulated intentionally, were performed in the time domain in order to assess the propagation velocity of different vibration modes through the construction elements. On this basis, conclusions were drawn in terms of the participation of various construction parts of the array of piezoelectric transducers in the process of creating the mechanical crosstalk. The elaborated FEM model allowed also to examine the ways aimed at reducing the transmission of mechanical crosstalk vibrations through the components of the array. Studies showed that correct cuts in the fasteners and the front layer improve the reduction of the mechanical crosstalk effect. The model can become a helpful tool in the process of design and modifications of manufactured ultrasonic arrays particularly in terms of mechanical crosstalk reduction. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Dynamic Mode Tuning of Ultrasonic Guided Wave Using an Array Transducer

    International Nuclear Information System (INIS)

    Kim, Young H.; Song, Sung J.; Park, Joon S.; Kim, Jae H.; Eom, Heung S.

    2005-01-01

    Ultrasonic guided waves have been widely employed for long range inspection of structures such as plates, rods and pipes. There are numerous modes with different wave velocities, and the appropriate mode selection is one of key techniques in the application of guided waves. In the present work, phase tuning by an array transducer was applied to generate ultrasonic guided waves. For this purpose, 8-channel ultrasonic pulser/receiver and their controller which enables sequential activation of each channels with given time delay were developed. Eight transducers were fabricated in order to generate guided waves by using an array transducer. The selective tuning of wave mode can be achieved by changing the interval between elements of an array transducer

  7. Theoretical characterization of annular array as a volumetric optoacoustic ultrasound handheld probe

    Science.gov (United States)

    Kalkhoran, Mohammad Azizian; Vray, Didier

    2018-02-01

    Optoacoustic ultrasound (OPUS) is a promising hybridized technique for simultaneous acquisition of functional and morphological data. The optical specificity of optoacoustic leverages the diagnostic aptitude of ultrasonography beyond anatomy. However, this integration has been rarely practiced for volumetric imaging. The challenge lies in the effective imaging probes that preserve the functionality of both modalities. The potentials of a sparse annular array for volumetric OPUS imaging are theoretically investigated. In order to evaluate and optimize the performance characteristics of the probe, series of analysis in the framework of system model matrix was carried out. The two criteria of voxel crosstalk and eigenanalysis have been employed to unveil information about the spatial sensitivity, aliasing, and number of definable spatial frequency components. Based on these benchmarks, the optimal parameters for volumetric handheld probe are determined. In particular, the number, size, and the arrangement of the elements and overall aperture dimension were investigated. The result of the numerical simulation suggests that the segmented-annular array of 128 negatively focused elements with 1λ × 20λ size, operating at 5-MHz central frequency showcases a good agreement with the physical requirement of both imaging systems. We hypothesize that these features enable a high-throughput volumetric passive/active ultrasonic imaging system with great potential for clinical applications.

  8. Slanted annular aperture arrays as enhanced-transmission metamaterials: Excitation of the plasmonic transverse electromagnetic guided mode

    Energy Technology Data Exchange (ETDEWEB)

    Ndao, Abdoulaye; Salut, Roland; Baida, Fadi I., E-mail: fbaida@univ-fcomte.fr [Département d' Optique P.M. Duffieux, Institut FEMTO-ST, UMR 6174 CNRS, Université de Franche–Comté, 25030 Besançon Cedex (France); Belkhir, Abderrahmane [Laboratoire de Physique et Chimie Quantique, Université Mouloud Mammeri, Tizi-Ouzou (Algeria)

    2013-11-18

    We present here the fabrication and the optical characterization of slanted annular aperture arrays engraved into silver film. An experimental enhanced transmission based on the excitation of the cutoff-less plasmonic guided mode of the nano-waveguides (the transmission electron microscopy mode) is demonstrated and agrees well with the theoretical predicted results. By the way, even if it is less efficient (70% → 20%), an enhanced transmission can occur at larger wavelength value (720 nm–930 nm) compared to conventional annular aperture arrays structure by correctly setting the metal thickness.

  9. Mosaic Process for the Fabrication of an Acoustic Transducer Array

    National Research Council Canada - National Science Library

    2005-01-01

    .... Deriving a geometric shape for the array based on the established performance level. Selecting piezoceramic materials based on considerations related to the performance level and derived geometry...

  10. Air-Coupled Low Frequency Ultrasonic Transducers and Arrays with PMN-32%PT Piezoelectric Crystals

    Directory of Open Access Journals (Sweden)

    Rymantas J. Kazys

    2017-01-01

    Full Text Available Air-coupled ultrasonic techniques are being increasingly used for material characterization, non-destructive evaluation of composite materials using guided waves as well as for distance measurements. Application of those techniques is mainly limited by the big losses of ultrasonic signals due to attenuation and mismatch of the acoustic impedances of ultrasonic transducers and air. One of the ways to solve this problem is by application of novel more efficient piezoelectric materials like lead magnesium niobate-lead titanate (PMN-PT type crystals. The objective of this research was the development and investigation of low frequency (<50 kHz wide band air-coupled ultrasonic transducers and arrays with an improved performance using PMN-32%PT crystals. Results of finite element modelling and experimental investigations of the developed transducers and arrays are presented. For improvement of the performance strip-like matching elements made of low acoustic impedance, materials such as polystyrene foams were applied. It allowed to achieve transduction losses for one single element transducer −11.4 dB, what is better than of commercially available air-coupled ultrasonic transducers. Theoretical and experimental investigations of the acoustic fields radiated by the eight element ultrasonic array demonstrated not only a good performance of the array in a pulse mode, but also very good possibilities to electronically focus and steer the ultrasonic beam in space.

  11. Studies on coaxial circular array for underwater transducer applications

    Digital Repository Service at National Institute of Oceanography (India)

    Chakraborty, B.

    of the coaxial array from the next stage of investigation during which a hybrid formulation is developed to provide a computationally efficient method of calculating impedance. Different sidelobe suppression techniques including uniform and nonuniform excitations...

  12. 2D sparse array transducer optimization for 3D ultrasound imaging

    International Nuclear Information System (INIS)

    Choi, Jae Hoon; Park, Kwan Kyu

    2014-01-01

    A 3D ultrasound image is desired in many medical examinations. However, the implementation of a 2D array, which is needed for a 3D image, is challenging with respect to fabrication, interconnection and cabling. A 2D sparse array, which needs fewer elements than a dense array, is a realistic way to achieve 3D images. Because the number of ways the elements can be placed in an array is extremely large, a method for optimizing the array configuration is needed. Previous research placed the target point far from the transducer array, making it impossible to optimize the array in the operating range. In our study, we focused on optimizing a 2D sparse array transducer for 3D imaging by using a simulated annealing method. We compared the far-field optimization method with the near-field optimization method by analyzing a point-spread function (PSF). The resolution of the optimized sparse array is comparable to that of the dense array.

  13. TOPICAL REVIEW: Capacitive micromachined ultrasonic transducer arrays for minimally invasive medical ultrasound

    Science.gov (United States)

    Chen, Jingkuang

    2010-02-01

    This paper reviews the minimally invasive capacitive micromachined ultrasonic transducer (CMUT) arrays for medical diagnosis and therapy. While piezoelectric transducers dominate today's medical ultrasound market, the capacitive micromachined ultrasonic transducer has recently emerged as a promising alternative which delivers a comparable device performance to its piezoelectric counterparts, is compatible with front-end circuit integration, allows high-density imager integration and is relative easy in miniaturization. Utilizing MEMS technology, the substrate of CMUT arrays can be micromachined into miniature platforms with various geometrical shapes, which include needles, three-dimensional prisms, as well as other flexible-substrate configurations. These arrays are useful for reaching deep inside the tissue or an organ with a minimally invasive approach. Due to the close proximity of the transducers to the target organ/tissue, a higher resolution/accuracy of diagnostic information can be achieved. In addition to pulse-echo and photoacoustic imaging, high-power CMUT devices capable of delivering ultrasounds with a pressure greater than 1.0 MPa have been monolithically integrated with imager CMUTs for image-guided therapy (IGT). Such miniature devices would facilitate diagnostic and therapy interventions not possible with conventional piezoelectric transducers.

  14. A row-column addressed micromachined ultrasonic transducer array for surface scanning applications.

    Science.gov (United States)

    Wong, Lawrence L P; Chen, Albert I H; Li, Zhenhao; Logan, Andrew S; Yeow, John T W

    2014-12-01

    Row-column addressed arrays for ultrasonic non-destructive testing (NDT) applications are analyzed and demonstrated in this paper. Simulation and experimental results of a row-column addressed 32 by 32 capacitive micromachined ultrasonic transducer (CMUT) array are presented. The CMUT array, which was designed for medical imaging applications, has a center frequency of 5.3MHz. The CMUT array was used to perform C-scans on test objects with holes that have diameters of 1.0mm and 0.5mm. The array transducer has an aperture size of 4.8mm by 4.8mm, and it was used to scan an area of 4.0mm by 4.0mm. Compared to an N by N fully addressed 2-D array, a row-column addressed array of the same number of elements requires fewer (N instead of N(2)) pairs of interconnection and supporting electronic components such as pulsers and amplifiers. Even though the resulting field of view is limit by the aperture size, row-column addressed arrays and the row-column addressing scheme can be an alternative option of 2-D arrays for NDT applications. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. High frequency copolymer ultrasonic transducer array of size-effective elements

    Science.gov (United States)

    Decharat, Adit; Wagle, Sanat; Habib, Anowarul; Jacobsen, Svein; Melandsø, Frank

    2018-02-01

    A layer-by-layer deposition method for producing dual-layer ultrasonic transducers from piezoelectric copolymers has been developed. The method uses a combination of customized and standard processing to obtain 2D array transducers with electrical connection of the individual elements routed directly to the rear of the substrate. A numerical model was implemented to study basic parameters effecting the transducer characteristics. Key elements of the array were characterized and evaluated, demonstrating its viability of 2D imaging. Signal reproducibility of the prototype array was studied by characterizing the variations of the center frequency (≈42 MHz) and bandwidth (≈25 MHz) of the acoustic. Object identification was also tested and parameterized by acoustic-field beamwidth as well as proper scan step size. Simple tests to illustrate a benefit of multi-element scan on lowering the inspection time were conducted. Structural imaging of the test structure underneath multi-layered wave media (glass plate and distilled water) was also performed. The prototype presented in this work is an important step towards realizing an inexpensive, compact array of individually operated copolymer transducers that can serve in a fast/volumetric high frequency (HF) ultrasonic scanning platform.

  16. Ultrasound therapy transducers with space-filling non-periodic arrays.

    Science.gov (United States)

    Raju, Balasundar I; Hall, Christopher S; Seip, Ralf

    2011-05-01

    Ultrasound transducers designed for therapeutic purposes such as tissue ablation, histotripsy, or drug delivery require large apertures for adequate spatial localization while providing sufficient power and steerability without the presence of secondary grating lobes. In addition, it is highly preferred to minimize the total number of channels and to maintain simplicity in electrical matching network design. To this end, we propose array designs that are both space-filling and non-periodic in the placement of the elements. Such array designs can be generated using the mathematical concept of non-periodic or aperiodic tiling (tessellation) and can lead to reduced grating lobes while maintaining full surface area coverage to deliver maximum power. For illustration, we designed two 2-D space-filling therapeutic arrays with 128 elements arranged on a spherical shell. One was based on the two-shape Penrose rhombus tiling, and the other was based on a single rectangular shape arranged non-periodically. The steerability performance of these arrays was studied using acoustic field simulations. For comparison, we also studied two other arrays, one with circular elements distributed randomly, and the other a periodic array with square elements. Results showed that the two space-filling non-periodic arrays were able to steer to treat a volume of 16 x 16 x 20 mm while ensuring that the grating lobes were under -10 dB compared with the main lobe. The rectangular non-periodic array was able to generate two and half times higher power than the random circles array. The rectangular array was then fabricated by patterning the array using laser scribing methods and its steerability performance was validated using hydrophone measurements. This work demonstrates that the concept of space-filling aperiodic/non-periodic tiling can be used to generate therapy arrays that are able to provide higher power for the same total transducer area compared with random arrays while maintaining

  17. Lamb and SH wave transducer arrays for the inspection of large areas of thick plates

    Science.gov (United States)

    Wilcox, P.; Lowe, M.; Cawley, P.

    2000-05-01

    The motivation for this work is to develop a rapid inspection system for large steel plates, such as those which the floors and walls of oil storage tanks are constructed from. One approach to inspecting plates using guided ultrasonic waves, is to design a transduction system which uses monolithic devices such as wedge transducers, inter-digital transducers or meander coil electro-magnetic acoustic transducers (EMATs). Unfortunately, in order to achieve a given level of performance at a particular operating point on the dispersion curves, the physical dimensions of a monolithic transducer must be scaled in proportion to the thickness of plate under inspection. This renders the use of monolithic devices on thicker plates increasingly impractical for several reasons, not least because of the cost and difficulties involved in manufacturing large devices. Also, particular monolithic devices are limited to a small range of applications since they are generally designed to be sensitive to a particular wavelength and to be either unfocused or have a fixed focal length. A more attractive solution is to use an array device containing a number of elements which behave individually as point transducers. By controlling the elements individually, wavelength selection, beam steering and focusing can all be performed by post processing the same set of test data. Encouraging experimental results obtained using this technique will be shown for several array designs which operate on 5-10 mm thick plates.

  18. Three-Dimensional Synthetic Aperture Focusing Using a Rocking Convex Array Transducer

    DEFF Research Database (Denmark)

    Andresen, Henrik; Nikolov, Svetoslav; Pedersen, Mads Møller

    2010-01-01

    Volumetric imaging can be performed using 1-D arrays in combination with mechanical motion. Outside the elevation focus of the array, the resolution and contrast quickly degrade compared with the lateral plane, because of the fixed transducer focus. This paper shows the feasibility of using...... synthetic aperture focusing for enhancing the elevation focus for a convex rocking array. The method uses a virtual source (VS) for defocused multi-element transmit, and another VS in the elevation focus point. This allows a direct time-of-flight to be calculated for a given 3-D point. To avoid artifacts...

  19. A single-input, single-output electromagnetically-transduced microresonator array

    International Nuclear Information System (INIS)

    Sabater, A B; Hunkler, A G; Rhoads, J F

    2014-01-01

    Resonant microsystems have found broad applicability in environmental and inertial sensing, signal filtering and timing applications. Despite this breadth in utility, a common constraint on these devices is throughput, or the total amount of information that they can process. In recent years, elastically-coupled arrays of microresonators have been used to increase the throughput in sensing contexts, but these arrays are often more complicated to design than their isolated counterparts, due to the potential for collective behaviors (such as vibration localization) to arise. An alternative solution to the throughput constraint is to use arrays of electromagnetically-transduced microresonators. These arrays can be designed such that the mechanical resonances are spaced far apart and the mechanical coupling between the microresonators is insignificant. Thus, when the entire array is actuated and sensed, a resonance in the electrical response can be directly correlated to a specific microresonator vibrating, as collective behaviors have been avoided. This work details the design, analysis and experimental characterization of an electromagnetically-transduced microresonator array in both low- and atmospheric-pressure environments, and demonstrates that the system could be used as a sensor in ambient conditions. While this device has direct application as a resonant-based sensor that requires only a single source and measurement system to track multiple resonances, with simple modification, this array could find uses in tunable oscillator and frequency multiplexing contexts. (paper)

  20. Theoretical thermal dosimetry produced by an annular phased array system in CT-based patient models

    International Nuclear Information System (INIS)

    Paulsen, K.D.; Strohbehn, J.W.; Lynch, D.R.

    1984-01-01

    Theoretical calculations for the specific absorption rate (SAR) and the resulting temperature distributions produced by an annular phased array (APA) type system are made. The finite element numerical method is used in the formulation of both the electromagnetic (EM) and the thermal boundary value problems. A number of detailed patient models based on CT-scan data from the pelvic, visceral, and thoracic regions are generated to stimulate a variety of tumor locations and surrounding normal tissues. The SAR values from the EM solution are input into the bioheat transfer equation, and steady-rate temperature distributions are calculated for a wide variety of blood flow rates. Based on theoretical modeling, the APA shows no preferential heating of superficial over deep-seated tumors. However, in most cases satisfactory thermal profiles (therapeutic volume near 60%) are obtained in all three regions of the human trunk only for tumors with little or no blood flow. Unsatisfactory temperature patterns (therapeutic volume <50%) are found for tumors with moderate to high perfusion rates. These theoretical calculations should aid the clinician in the evaluation of the effectiveness of APA type devices in heating tumors located in the trunk region

  1. On the control and prediction of the heating patterns of the annular phased array hyperthermia system

    International Nuclear Information System (INIS)

    Iskander, M.F.; Turner, P.F.; Knight, G.

    1984-01-01

    In previous publications the authors examined the electromagnetic (EM) power deposition and heating of the Annular Phased Array (APA) system developed by BSD Medical Corporation, using numerical EM and thermodynamics modeling. In this paper the results of recent efforts to vary and control the heating patterns produced by this system are described. in particular, data from several numerical simulations and experimental measurements are presented which illustrate the effect on the heating patterns achieved by varying the phase difference between the different ports of the APA system. Other heating patterns, produced by inactivating some of the APA ports, are also discussed. The remainder of the paper focuses on the feasibility of predicting the EM power depositions patterns of the APA solely through monitoring the E-field in the water bolus around the patient's body. In particular, it is shown that this E-field distribution depends primarily upon the outer geometry of the human body and is largely insensitive to the detailed distribution of inner tissues. Specific suggestions regarding the types, number, and location of E-field probes that can be used for such measurements are also given

  2. 2D array transducers for real-time 3D ultrasound guidance of interventional devices

    Science.gov (United States)

    Light, Edward D.; Smith, Stephen W.

    2009-02-01

    We describe catheter ring arrays for real-time 3D ultrasound guidance of devices such as vascular grafts, heart valves and vena cava filters. We have constructed several prototypes operating at 5 MHz and consisting of 54 elements using the W.L. Gore & Associates, Inc. micro-miniature ribbon cables. We have recently constructed a new transducer using a braided wiring technology from Precision Interconnect. This transducer consists of 54 elements at 4.8 MHz with pitch of 0.20 mm and typical -6 dB bandwidth of 22%. In all cases, the transducer and wiring assembly were integrated with an 11 French catheter of a Cook Medical deployment device for vena cava filters. Preliminary in vivo and in vitro testing is ongoing including simultaneous 3D ultrasound and x-ray fluoroscopy.

  3. Optical vibration measurements of cross coupling effects in capacitive micromachined ultrasonic transducer arrays

    Science.gov (United States)

    Leirset, Erlend; Aksnes, Astrid

    2011-05-01

    Optical vibration measurement systems are excellent tools for characterizing ultrasonic transducers. This paper presents measurements on immersed arrays of capacitive ultrasonic transducers (CMUTs) using a heterodyne interferometer. The interferometer allows measurements of vibrations from DC up to 1 GHz with a noise floor of ~1pm/√Hz. Previously CMUTs have been characterized in air. The transducer is intended for intravascular use. Therefore the CMUTs were characterized in the transparent fluids kerosene and rapeseed oil that have acoustic properties closer to blood. The optical measurements on immersed CMUTs were validated by assessing the measurement errors caused by the acousto optic effects in the fluid. When immersed there is significant cross coupling between individual CMUTs within an array. Simulations presented here indicate that this causes an acoustic wave mode that is bound to the interface between the CMUTs and the fluid. This is confirmed by measurements of the phase velocity and attenuation coefficient of this wave. The measurement results indicate that the wave exists up to a maximum frequency and that the attenuation constant increases with increasing frequency. Rapeseed oil causes a significantly larger attenuation coefficient than kerosene, which most probably is due to a considerable difference in fluid viscosities. There was a mismatch between the simulated and measured phase velocity for low frequencies. It is likely that the cause of this is coupling between the fluid CMUT interface waves and Lamb waves in the substrate of the CMUT array. Measurements performed with the heterodyne interferometer have confirmed the presence of dispersive waves bound to the surface of the transducer by directly showing their propagation along the array. The setup has also characterized the bound waves by measuring dispersion relations.

  4. Acoustic resolution photoacoustic Doppler flowmetry using a transducer array: optimising processing for velocity contrast

    Science.gov (United States)

    Bücking, T. M.; van den Berg, P. J.; Balabani, S.; Steenbergen, W.; Beard, P. C.; Brunker, J.

    2017-03-01

    This work demonstrates the first measurements of blood flow velocity using photoacoustic flowmetry (PAF) employing a transducer array. The measurements were made in a flow phantom consisting of a tube (580 μm inner diameter) containing blood flowing steadily at physiological speeds ranging from 3 mm/s to 25 mm/s. Velocity measurements were based on the generation of two successive photoacoustic (PA) signals using two laser pulses with a wavelength of 1064 nm; the PA signals were detected using a 64-element transducer array with a -6 dB detection bandwidth of 11-17 MHz. We developed a processing pipeline to optimise a cross-correlation based velocity measurement method comprising the following processing steps: image reconstruction, filtering, displacement detection, and masking. We found no difference in flow detection accuracy when choosing different image reconstruction algorithms (time reversal, Fourier transformation, and delay-and-sum). High-pass filtering and wallfiltering were however found to be essential pre-processing steps in order to recover the correct displacement information. We masked the calculated velocity map based on the amplitude of the cross-correlation function in order to define the region of interest corresponding to highest signal amplitude. These developments enabled blood flow measurements using a transducer array, bringing PAF one step closer to clinical applicability.

  5. Acoustical imaging using capacitive micromachined ultrasonic transducer arrays: Devices, circuits, and systems

    Science.gov (United States)

    Oralkan, Omer

    Integrated circuit technologies have had a great impact on the development of medical devices. Diagnostic imaging systems have benefited tremendously from the improvements in integrated circuits. One of the recent examples of this interaction between the two disciplines occurred in the area of ultrasonic imaging. The ability to build structures with dimensions in the submicron range enabled the realization of an almost a century old idea: Capacitive ultrasonic transducers. The major advantages of this transducer technology are ease of fabrication, potential for integration with supporting electronic circuits and improved bandwidth and sensitivity. This dissertation analyzes the viability of capacitive micromachined ultrasonic transducers (CMUTs) for practical imaging applications. This analysis is conducted by a detailed characterization effort, and by demonstrating both 2-D and 3-D images. Acoustical performance of 1-D and 2-D CMUT arrays fabricated using silicon integrated circuit technology has been experimentally characterized for transmit and receive modes, and the results are found to be in good agreement with the theoretical expectations. Both 2-D and 3-D images have been demonstrated. The distinctive features of CMUTs manifest themselves in the results of the characterization experiments and also in the resulting images. This dissertation also describes a general approach to design integrated front-end circuits for ultrasonic imaging and demonstrates basic circuit blocks for use in integrated systems along with CMUT arrays. The integration of the ultrasonic transducer arrays with supporting electronics not only reduces the cost and complexity of the system but also provides several advantages such as reduced parasitics, improved sensitivity, and a compact design with a reduced number of external interconnects. In this study, a custom integrated circuit comprising a pulse driver, a transmit/receive (T/R) switch and a wideband preamplifier has been fabricated

  6. Multiview Hilbert transformation in full-ring transducer array-based photoacoustic computed tomography

    Science.gov (United States)

    Li, Lei; Zhu, Liren; Shen, Yuecheng; Wang, Lihong V.

    2017-07-01

    Based on the photoacoustic (PA) effect, PA tomography directly measures specific optical absorption, i.e., absorbed optical energy per unit volume. We recently developed a full-ring ultrasonic transducer array-based photoacoustic computed tomography (PACT) system for small-animal whole-body imaging. The system has a full-view detection angle and high in-plane resolution (˜100 μm). However, due to the bandpass frequency response of the piezoelectric transducer elements and the limited elevational detection coverage of the full-ring transducer array, the reconstructed images present bipolar (i.e., both positive and negative) pixel values, which cause ambiguities in image interpretation for physicians and biologists. We propose a multiview Hilbert transformation method to recover the unipolar initial pressure for full-ring PACT. The effectiveness of the proposed algorithm was first validated by numerical simulations and then demonstrated with ex vivo mouse brain structural imaging and in vivo mouse whole-body imaging.

  7. High frequency ultrasonic imaging using thermal mechanical noise recorded on capacitive micromachined transducer arrays

    Science.gov (United States)

    Lani, Shane; Satir, Sarp; Gurun, Gokce; Sabra, Karim G.; Levent Degertekin, F.

    2011-11-01

    The cross-correlation of diffuse thermal-mechanical noise recorded by two sensors yields an estimate of the ultrasonic waves propagating between them. We used this approach at high frequencies (1-30 MHz) on a capacitive micromachined ultrasonic transducer (CMUT) ring array (d = 725 μm), monolithically integrated with low noise complementary metal oxide semiconductor electronics. The thermal-mechanical noise cross-correlations between the CMUT array elements in immersion reveal both evanescent surface waves (below 10 MHz) and waves propagating primarily in the fluid (above 10 MHz). These propagating waves may allow passive imaging of scatterers closer to the array as compared to conventional pulse-echo systems, providing potentially higher resolution.

  8. Fabrication of Vacuum-Sealed Capacitive Micromachined Ultrasonic Transducer Arrays Using Glass Reflow Process

    Directory of Open Access Journals (Sweden)

    Nguyen Van Toan

    2016-04-01

    Full Text Available This paper presents a process for the fabrication of vacuum-sealed capacitive micromachined ultrasonic transducer (CMUT arrays using glass reflow and anodic bonding techniques. Silicon through-wafer interconnects have been investigated by the glass reflow process. Then, the patterned silicon-glass reflow wafer is anodically bonded to an SOI (silicon-on-insulator wafer for the fabrication of CMUT devices. The CMUT 5 × 5 array has been successfully fabricated. The resonant frequency of the CMUT array with a one-cell radius of 100 µm and sensing gap of 3.2 µm (distance between top and bottom electrodes is observed at 2.84 MHz. The Q factor is approximately 1300 at pressure of 0.01 Pa.

  9. Applications of Flexible Ultrasonic Transducer Array for Defect Detection at 150 °C

    Directory of Open Access Journals (Sweden)

    Jiunn-Woei Liaw

    2013-01-01

    Full Text Available In this study, the feasibility of using a one dimensional 16-element flexible ultrasonic transducer (FUT array for nondestructive testing at 150 °C is demonstrated. The FUT arrays were made by a sol-gel sprayed piezoelectric film technology; a PZT composite film was sprayed on a titanium foil of 75 µm thickness. Since the FUT array is flexible, it was attached to a steel pipe with an outer diameter of 89 mm and a wall thickness of 6.5 mm at 150 °C. Using the ultrasonic pulse-echo mode, pipe thickness measurements could be performed. Moreover, using the ultrasonic pulse-echo and pitch-catch modes of each element of FUT array, the defect detection was performed on an Al alloy block of 30 mm thickness with a side-drilled hole (SDH of f3 mm at 150 °C. In addition, a post-processing algorithm based on the total focusing method was used to process the full matrix of these A-scan signals of each single transmitter and multi-receivers, and then the phase-array image was obtained to indicate this defect- SDH. Both results show the capability of FUT array being operated at 150 °C for the corrosion and defect detections.

  10. A novel, flat, electronically-steered phased array transducer for tissue ablation: preliminary results

    International Nuclear Information System (INIS)

    Ellens, Nicholas P K; Lucht, Benjamin B C; Gunaseelan, Samuel T; Hudson, John M; Hynynen, Kullervo H

    2015-01-01

    Flat, λ/2-spaced phased arrays for therapeutic ultrasound were examined in silico and in vitro. All arrays were made by combining modules made of 64 square elements with 1.5 mm inter-element spacing along both major axes. The arrays were designed to accommodate integrated, co-aligned diagnostic transducers for targeting and monitoring. Six arrays of 1024 elements (16 modules) and four arrays of 6144 elements (96 modules) were modelled and compared according to metrics such as peak pressure amplitude, focal size, ability to be electronically-steered far off-axis and grating lobe amplitude. Two 1024 element prototypes were built and measured in vitro, producing over 100 W of acoustic power. In both cases, the simulation model of the pressure amplitude field was in good agreement with values measured by hydrophone. Using one of the arrays, it was shown that the peak pressure amplitude dropped by only 24% and 25% of the on-axis peak pressure amplitude when steered to the edge of the array (40 mm) at depths of 30 mm and 50 mm. For the 6144 element arrays studied in in silico only, similarly high steerability was found: even when steered 100 mm off-axis, the pressure amplitude decrease at the focus was less than 20%, while the maximum pressure grating lobe was only 20%. Thermal simulations indicate that the modules produce more than enough acoustic power to perform rapid ablations at physiologically relevant depths and steering angles. Arrays such as proposed and tested in this study have enormous potential: their high electronic steerability suggests that they will be able to perform ablations of large volumes without the need for any mechanical translation. (paper)

  11. Quantitative analysis of temperature dependent acoustic trapping characteristics by using concentric annular type dual element ultrasonic transducer.

    Science.gov (United States)

    Chung, In-Young; Lee, Jungwoo

    2015-02-01

    This paper presents the temperature dependence of lateral acoustic trapping capability by probing the speed of sound in individual lipid droplets at a given temperature of water and measuring its corresponding displacement, a value for quantitatively evaluating a spring-like behavior of the acoustic trap with certain strength. A 20/40 MHz dual element LiNbO3 ultrasonic transducer is fabricated to simultaneously perform both transverse trapping and sound speed measurement for each droplet over a discrete temperature range from 20°C to 30°C. Time of flight method is employed for pulse tracking that determines the arrival time of an echo reflected back from either a trapped droplet or a mylar film. The estimated speeds of sound in water and droplets are 1484.8 m/s and 1431.6 m/s at 20°C, while 1506.0 m/s and 1400.6 m/s at 30°C, respectively. As the temperature rises, the sound speed in droplets decreases at an average rate of 3.1 m/s/°C, and the speed in water increases at 2.1 m/s/°C. The average displacement varies from 150.0 μm to 179.0 μm with an increasing rate of 2.9 μm/°C, and its standard deviation is obtained between 1.0 μm and 2.0 μm over the same temperature range. Reduced sound speed as a function of rising temperature results in increased displacement, indicating that the trapping strength is adjustable by regulating ambient temperature in water as well as by changing transducer excitation parameters. Therefore, the results suggest that the temperature dependence of this trapping technique can be exploited for developing a remote manipulation tool of micron-sized particles in a thermally fluctuating environment. It is also shown that any deviated trapping strength caused by thermal disturbance near the trap can be restored to its desired level by compensating either temperature difference or trapping system condition. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. The design of a focused ultrasound transducer array for the treatment of stroke: a simulation study

    International Nuclear Information System (INIS)

    Pajek, Daniel; Hynynen, Kullervo

    2012-01-01

    High intensity focused ultrasound (HIFU) is capable of mechanically disintegrating blood clots at high pressures. Safe thrombolysis may require frequencies higher than those currently utilized by transcranial HIFU. Since the attenuation and focal distortion of ultrasound in bone increases at higher frequencies, resulting focal pressures are diminished. This study investigated the feasibility of using transcranial HIFU for the non-invasive treatment of ischemic stroke. The use of large aperture, 1.1–1.5 MHz phased arrays in targeting four clinically relevant vessel locations was simulated. Resulting focal sizes decreased with frequency, producing a maximum –3 dB depth of field and lateral width of 2.0 and 1.2 mm, respectively. Mean focal gains above an order of magnitude were observed in three of four targets and transducer intensities required to achieve thrombolysis were determined. Required transducer element counts are about an order of magnitude higher than what currently exists and so, although technically feasible, new arrays would need to be developed to realize this as a treatment modality for stroke. (paper)

  13. Multi-Focus Beamforming for Thermal Strain Imaging Using a Single Ultrasound Linear Array Transducer.

    Science.gov (United States)

    Nguyen, Man M; Ding, Xuan; Leers, Steven A; Kim, Kang

    2017-06-01

    Ultrasound-induced thermal strain imaging (TSI) has been used successfully to identify lipid- and water-based tissues in atherosclerotic plaques in some research settings. However, TSI faces several challenges to be realized in clinics. These challenges include motion artifacts and displacement tracking accuracy, as well as limited heating capability, which contributes to low thermal strain signal-to-noise ratio, and a limited field of view. Our goal was to address the challenge in heating tissue in TSI. Current TSI systems use separate heating and imaging transducers, which require physical alignment of the heating and imaging beams and result in a bulky setup that limits in vivo operation. We evaluated a new design for heating beams that can be implemented on a linear array imaging transducer and can provide improved heating area and efficiency as compared with previous implementations. The heating beams designed were implemented with a clinical linear array imaging transducer connected to a research ultrasound platform. In vitro experiments using tissue-mimicking phantoms with no blood flow revealed that the new design resulted in an effective heating area of approximately 0.85 cm 2 and a 0.3°C temperature rise in 2 s of heating, which compared well with in silico finite-element simulations. With the new heating beams, TSI was found to be able to detect a lipid-mimicking rubber inclusion with a diameter of 1 cm from the water-based gelatin background, with a strain contrast of 2.3 (+0.14% strain in the rubber inclusion and -0.06% strain in the gelatin background). Lastly, lipid-based tissue in a 1-cm-diameter human carotid endarterectomy (CEA) sample was identified in good agreement with histology. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  14. Packaging and modular assembly of large-area and fine-pitch 2-D ultrasonic transducer arrays.

    Science.gov (United States)

    Lin, Der-Song; Wodnicki, Robert; Zhuang, Xuefeng; Woychik, Charles; Thomenius, Kai E; Fisher, Rayette A; Mills, David M; Byun, Albert J; Burdick, William; Khuri-Yakub, Pierre; Bonitz, Barry; Davies, Todd; Thomas, Glen; Otto, Bernd; Töpper, Michael; Fritzsch, Thomas; Ehrmann, Oswin

    2013-07-01

    A promising transducer architecture for largearea arrays employs 2-D capacitive micromachined ultrasound transducer (CMUT) devices with backside trench-frame pillar interconnects. Reconfigurable array (RA) application-specified integrated circuits (ASICs) can provide efficient interfacing between these high-element-count transducer arrays and standard ultrasound systems. Standard electronic assembly techniques such as flip-chip and ball grid array (BGA) attachment, along with organic laminate substrate carriers, can be leveraged to create large-area arrays composed of tiled modules of CMUT chips and interface ASICs. A large-scale, fully populated and integrated 2-D CMUT array with 32 by 192 elements was developed and demonstrates the feasibility of these techniques to yield future large-area arrays. This study demonstrates a flexible and reliable integration approach by successfully combining a simple under-bump metallization (UBM) process and a stacked CMUT/interposer/ASIC module architecture. The results show high shear strength of the UBM (26.5 g for 70-μm balls), high interconnect yield, and excellent CMUT resonance uniformity (s = 0.02 MHz). A multi-row linear array was constructed using the new CMUT/interposer/ASIC process using acoustically active trench-frame CMUT devices and mechanical/ nonfunctional Si backside ASICs. Imaging results with the completed probe assembly demonstrate a functioning device based on the modular assembly architecture.

  15. Numerical implementation of magneto-acousto-electrical tomography (MAET) using a linear phased array transducer

    Science.gov (United States)

    Soner Gözü, Mehmet; Zengin, Reyhan; Güneri Gençer, Nevzat

    2018-02-01

    In this study, the performance and implementation of magneto-acousto-electrical tomography (MAET) is investigated using a linear phased array (LPA) transducer. The goal of MAET is to image the conductivity distribution in biological bodies. It uses the interaction between ultrasound and a static magnetic field to generate velocity current density distribution inside the body. The resultant voltage due to velocity current density is sensed by surface electrodes attached on the body. In this study, the theory of MAET is reviewed. A 16-element LPA transducer with 1 MHz excitation frequency is used to provide beam directivity and steerability of acoustic waves. Different two-dimensional numerical models of breast and tumour are formed to analyze the multiphysics problem coupled with acoustics and electromagnetic fields. In these models, velocity current density distributions are obtained for pulse type ultrasound excitations. The static magnetic field is assumed as 1 T. To sense the resultant voltage caused by the velocity current density, it is assumed that two electrodes are attached on the surface of the body. The performance of MAET is shown through sensitivity matrix analysis. The sensitivity matrix is obtained for two transducer positions with 13 steering angles between -30\\circ to 30\\circ with 5\\circ angular intervals. For the reconstruction of the images, truncated singular value decomposition method is used with different signal-to-noise ratio (SNR) values (20 dB, 40 dB, 60 dB and 80 dB). The resultant images show that the perturbation (5 mm  ×  5 mm) placed 35 mm depth can be detected even if the SNR is 20 dB.

  16. Characterization and Optimization Design of the Polymer-based Capacitive Micro-arrayed Ultrasonic Transducer

    Directory of Open Access Journals (Sweden)

    De-Yi CHIOU

    2007-10-01

    Full Text Available The polymer-based capacitive micro-arrayed ultrasonic transducers have been investigated using the finite element analysis. The ANSYS Multiphysics solver with sequential approach and the physics environment files are applied for the solution of the electrostatic-structural coupled-field problem. A 2-D electromechanical model is established to characterize the collapse voltage and the resonant frequency of the P-CMUT. Both the numerical and experimental results were in good agreement. An integrated multi-objective design method involving electrical and mechanical characterization was developed to optimize the geometric parameters of the P-CMUT. The optimization search routine conducted using the genetic algorithm (GA is connected with the ANSYS model to obtain the best design variable. The optimal results show that the proposed approach provides another efficient and versatile numerical tool for multi-objective design and optimization of the P-CMUT.

  17. Deep Tissue Photoacoustic Imaging Using a Miniaturized 2-D Capacitive Micromachined Ultrasonic Transducer Array

    Science.gov (United States)

    Kothapalli, Sri-Rajasekhar; Ma, Te-Jen; Vaithilingam, Srikant; Oralkan, Ömer

    2014-01-01

    In this paper, we demonstrate 3-D photoacoustic imaging (PAI) of light absorbing objects embedded as deep as 5 cm inside strong optically scattering phantoms using a miniaturized (4 mm × 4 mm × 500 µm), 2-D capacitive micromachined ultrasonic transducer (CMUT) array of 16 × 16 elements with a center frequency of 5.5 MHz. Two-dimensional tomographic images and 3-D volumetric images of the objects placed at different depths are presented. In addition, we studied the sensitivity of CMUT-based PAI to the concentration of indocyanine green dye at 5 cm depth inside the phantom. Under optimized experimental conditions, the objects at 5 cm depth can be imaged with SNR of about 35 dB and a spatial resolution of approximately 500 µm. Results demonstrate that CMUTs with integrated front-end amplifier circuits are an attractive choice for achieving relatively high depth sensitivity for PAI. PMID:22249594

  18. Simulation of an Electromagnetic Acoustic Transducer Array by Using Analytical Method and FDTD

    Directory of Open Access Journals (Sweden)

    Yuedong Xie

    2016-01-01

    Full Text Available Previously, we developed a method based on FEM and FDTD for the study of an Electromagnetic Acoustic Transducer Array (EMAT. This paper presents a new analytical solution to the eddy current problem for the meander coil used in an EMAT, which is adapted from the classic Deeds and Dodd solution originally intended for circular coils. The analytical solution resulting from this novel adaptation exploits the large radius extrapolation and shows several advantages over the finite element method (FEM, especially in the higher frequency regime. The calculated Lorentz force density from the analytical EM solver is then coupled to the ultrasonic simulations, which exploit the finite-difference time-domain (FDTD method to describe the propagation of ultrasound waves, in particular for Rayleigh waves. Radiation pattern obtained with Hilbert transform on time-domain waveforms is proposed to characterise the sensor in terms of its beam directivity and field distribution along the steering angle, which can produce performance parameters for an EMAT array, facilitating the optimum design of such sensors.

  19. Simulation-based optimization of the design and settings of ultrasonic phased-array transducers with an evolutionary algorithm

    International Nuclear Information System (INIS)

    Puel, B.; Chatillon, S.; Calmon, P.; Lesselier, D.

    2011-01-01

    The design of an ultrasonic array and its settings for a specific inspection involves multiple parameters and is the result of a compromise between different requirements and limitations. Parametric studies based on simulation tools are often performed to ensure that the transducer has suitable performances in terms of detection of the defects sought. An automatic optimization tool, based on an evolutionary algorithm driving CIVA's simulation data, is proposed and tested in realistic applications to design inspection parameters (designing, positioning and/or setting the transducer). (authors)

  20. Acoustic-emission source location using ''face-centered'' transducer arrays

    International Nuclear Information System (INIS)

    Hatano, Hajime; Hanajima, Takatoshi; Niwa, Noboru.

    1978-01-01

    A new method to locate the source of acoustic emission is introduced. Acoustic emission detectors are placed on a body to be investigated, and the signals from face-centered transducer arrays are analysed. Since the time-difference counter indicates directly the position of the source of acoustic emission, the source location system of real time can be constructed without any computer or peripheral instruments. The calculation of location is made by approximation, and the error due to the approximation is estimated. The upper limit of error is estimated to be 1.5 percent of lattice distance. Test experiment was performed with an aluminum plate, on which a steel ball was dropped and sound was generated. Experimental location was in good agreement with the theoretical location. The transmission loss of sound waves may be caused in some case, since the distance between the sound source and the detector is large in this method. However, it was found that this effect was negligible. The error due to the present method is less than the thickness of plates. The amount of error may be about one wave length of sound waves. (Kato, T.)

  1. Numerical Analysis of Ultrasonic Beam Profile Due to the Change of the Number of Piezoelectric Elements for Phased Array Transducer

    International Nuclear Information System (INIS)

    Choi, Sang Woo; Lee, Joon Hyun

    1999-01-01

    A phased array is a multi-element piezoelectric device whose elements are individually excited by electric pulses at programmed delay time. One of the advantages of using phased array in nondestructive evaluation (NDE) application over conventional ultrasonic transducers is their great maneuverability of ultrasonic beam. There are some parameters such as the number and the size of the piezoelectric elements and the inter-element spacing of the elements to design phased array transducer. In this study, the characteristic of ultrasonic beam for phased array transducer due to the variation of the number of elements has been simulated for ultrasonic SH-wave on the basis of Huygen's principle. Ultrasonic beam directivity and focusing due to the change of time delay of each element were discussed due to the change of the number of piezoelectric elements. It was found that ultrasonic beam was much more spreaded and hence its sound pressure was decreased as steering angle of ultrasonic beam was increased. In addition, the ability of ultrasonic bean focusing decreased gradually with the increase of focal length at the same piezoelectric elements. However, the ability of beam focusing was improved as the number of consisting elements was increased

  2. Techniques for heating eccentrically located tumors with the BSD annular phased array system (APAS): Clinical experience

    International Nuclear Information System (INIS)

    Samulski, T.V.; Kapp, D.S.; Bagshaw, M.A.; Fessenden, P.; Lee, E.R.; Lohrbach, A.W.

    1985-01-01

    The authors are currently investigating the potential for treatment optimization with the BSD APAS in tumors which are eccentrically located within the lower abdomen and pelvis. Attempts have been made to manipulate electric field (E-field) distribution during treatments through frequency changes and partial array activation (driving less than all four quadrants). Field shifts are qualitatively documented using the manufacturer's supplied diode array probes located at the patient/bolus interface in anterior, posterior and bilateral positions. Preliminary findings indicate that the internal E-field distributions can be manipulated to result in better treatment tolerance and better temperature distributions in selected target volumes. Phantom and clinical data are presented demonstrating the utility of these approaches

  3. Development of a multi-band photoacoustic tomography imaging system based on a capacitive micromachined ultrasonic transducer array.

    Science.gov (United States)

    Zhang, Jian; Pun, Sio Hang; Yu, Yuanyu; Gao, Duyang; Wang, Jiujiang; Mak, Peng Un; Lei, Kin Fong; Cheng, Ching-Hsiang; Yuan, Zhen

    2017-05-10

    Photoacoustic tomography (PAT) as a hybrid technology combines the high optical contrast and high acoustic resolution in a single imaging modality. However, most of the available PAT systems cannot comprehensively or accurately characterize biological systems at multiple length scales due to the use of narrow bandwidth commercial ultrasonic transducers. In this study, we fabricated a novel multi-band capacitive micromachined ultrasonic transducer (CMUT) array, and first developed a CMUT-based multi-band photoacoustic tomography (MBPAT) imaging system. The MBPAT imaging system was examined by the phantom experiment, and then was successfully applied to image the zebrafish in vivo. The imaging results indicated that CMUT-array-based MBPAT can provide a more comprehensive and accurate characterization of biological tissues, which exhibit the potential of MBPAT/CMUT in various areas of biomedical imaging.

  4. Pulse Generator for Ultrasonic Piezoelectric Transducer Arrays Based on a Programmable System-on-Chip (PSoC

    Directory of Open Access Journals (Sweden)

    Pedro Acevedo

    2017-04-01

    Full Text Available This paper describes the design of a pulse generator to excite PZT and PVDF ultrasonic transducer arrays, based on the Programmable System-on-Chip (PSoC module. In this module, using programmable logic different pulses were implemented; these pulses are required in ultrasonic applications for multiple channels to excite PZT and PVDF transducer arrays. To excite multiple elements, bursts are required which can be generated simultaneously or out of phase, generating dynamic wave fronts. For medical applications where bidirectional blood flow is detected burst and quadrature pulses are used. These pulses can be generated independently or in combinations, as simultaneous pulses, shift pulses or burst. This module can operate with programmable frequencies from 3-74 MHz; its programming may be versatile covering a wide range of ultrasonic applications.

  5. An MR-compliant phased-array HIFU transducer with augmented steering range, dedicated to abdominal thermotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Auboiroux, Vincent [Inserm, U556, Lyon, F-69003 (France); Dumont, Erik [Image Guided Therapy, Pessac, Bordeaux (France); Petrusca, Lorena; Salomir, Rares [Faculty of Medicine, University of Geneva (Switzerland); Viallon, Magalie, E-mail: vincent.auboiroux@unige.ch [Radiology Department, University Hospital of Geneva, Geneva (Switzerland)

    2011-06-21

    A novel architecture for a phased-array high intensity focused ultrasound (HIFU) device was investigated, aiming to increase the capabilities of electronic steering without reducing the size of the elementary emitters. The principal medical application expected to benefit from these developments is the time-effective sonication of large tumours in moving organs. The underlying principle consists of dividing the full array of transducers into multiple sub-arrays of different resonance frequencies, with the reorientation of these individual emitters, such that each sub-array can focus within a given spatial zone. To enable magnetic resonance (MR) compatibility of the device and the number of output channels from the RF generator to be halved, a passive spectral multiplexing technique was used, consisting of parallel wiring of frequency-shifted paired piezoceramic emitters with intrinsic narrow-band response. Two families of 64 emitters (circular, 5 mm diameter) were mounted, with optimum efficiency at 0.96 and 1.03 MHz, respectively. Two different prototypes of the HIFU device were built and tested, each incorporating the same two families of emitters, but differing in the shape of the rapid prototyping plastic support that accommodated the transducers (spherical cap with radius of curvature/aperture of 130 mm/150 mm and, respectively, 80 mm/110 mm). Acoustic measurements, MR-acoustic radiation force imaging (ex vivo) and MR-thermometry (ex vivo and in vivo) were used for the characterization of the prototypes. Experimental results demonstrated an augmentation of the steering range by 80% along one preferentially chosen axis, compared to a classic spherical array of the same total number of elements. The electric power density provided to the piezoceramic transducers exceeded 50 W cm{sup -2} CW, without circulation of coolant water. Another important advantage of the current approach is the versatility of reshaping the array at low cost.

  6. An MR-compliant phased-array HIFU transducer with augmented steering range, dedicated to abdominal thermotherapy

    Science.gov (United States)

    Auboiroux, Vincent; Dumont, Erik; Petrusca, Lorena; Viallon, Magalie; Salomir, Rares

    2011-06-01

    A novel architecture for a phased-array high intensity focused ultrasound (HIFU) device was investigated, aiming to increase the capabilities of electronic steering without reducing the size of the elementary emitters. The principal medical application expected to benefit from these developments is the time-effective sonication of large tumours in moving organs. The underlying principle consists of dividing the full array of transducers into multiple sub-arrays of different resonance frequencies, with the reorientation of these individual emitters, such that each sub-array can focus within a given spatial zone. To enable magnetic resonance (MR) compatibility of the device and the number of output channels from the RF generator to be halved, a passive spectral multiplexing technique was used, consisting of parallel wiring of frequency-shifted paired piezoceramic emitters with intrinsic narrow-band response. Two families of 64 emitters (circular, 5 mm diameter) were mounted, with optimum efficiency at 0.96 and 1.03 MHz, respectively. Two different prototypes of the HIFU device were built and tested, each incorporating the same two families of emitters, but differing in the shape of the rapid prototyping plastic support that accommodated the transducers (spherical cap with radius of curvature/aperture of 130 mm/150 mm and, respectively, 80 mm/110 mm). Acoustic measurements, MR-acoustic radiation force imaging (ex vivo) and MR-thermometry (ex vivo and in vivo) were used for the characterization of the prototypes. Experimental results demonstrated an augmentation of the steering range by 80% along one preferentially chosen axis, compared to a classic spherical array of the same total number of elements. The electric power density provided to the piezoceramic transducers exceeded 50 W cm-2 CW, without circulation of coolant water. Another important advantage of the current approach is the versatility of reshaping the array at low cost.

  7. Design and analysis of an ultrasonic transducer micro-array for near-field imaging of age related macular degeneration

    Science.gov (United States)

    Clarke, Clyde C.

    Obtaining quantitative data about tissue has been a goal of ultrasonography since its inception, such data provides invaluable information for diagnosing disease. Traditional ultrasound imaging techniques (B-Mode, C-Mode and M-Mode) have been used to diagnose diseases from images of organs. However, images obtained via these techniques, in some cases, provide limited information about the pathology of the tissues being examined. This is because much of the information that is used for diagnosis depends upon qualitative cues emerging from the echoic profiles of bulk tissue properties. In order to obtain quantitative information about tissue properties, an understanding of the interaction of the ultrasound system proper and tissue is necessary. This requires the creation of detailed models of both the ultrasound imaging system and tissue. These models enable us to obtain quantitative information about tissue, by examining features of backscattered data, generated by the interaction of the ultrasonic imaging system with the tissue under examination. Imaging systems are typically designed with little consideration of the constraints of the imaging environment or the acoustic features of the tissue which include impedance, scatterer size, shape and density. We propose to take into account the physical properties of tissue in designing ultrasonic imaging arrays. We develop a framework for designing ultrasonic imaging systems (primarily the transducer and transducer array) with physical parameters that are tuned to detect specific features of tissue. The design methodology obtains the parameters of an NxN transducer array constrained to a size of e.g. 2mm x 2mm (the size required for medical imaging). The physical parameters of the transducer elements are also obtained for capacitive micromachined ultrasonic transducer (cMUT) technology. In addition to the overall size constraints (2 mm x 2 mm), several other constraints put limitation upon the possible system

  8. On the steering of sound energy through a supercritical plate by a near-field transducer array.

    Science.gov (United States)

    Anderson, Brian E; Hughes, W Jack; Hambric, Stephen A

    2008-05-01

    The ability to direct sound energy through the flexural vibrations of a submerged plate at various angles of incidence using a near-field transducer array is investigated. An alumina bar is placed in front of a one-dimensional, eight-element transducer array, between the array and the water. Operating in a receive mode, data were taken as a function of angle of incidence and compared to data taken without the presence of the alumina bar. The array was also operated in transmit mode and results were compared to corresponding receive mode data, showing that reciprocity holds. Results show that in fact sound energy can be steered through a plate, and that the measurement method used provides a convenient method of measuring the angular dependence of transmission through a plate, including measurements at frequencies above the plate's critical frequency. Experimental results of sound transmission versus angle of incidence of finite sized plates agree qualitatively with theoretical results from an analysis of the transmission through an unbounded flexible partition.

  9. A Flexible Ultrasound Transducer Array with Micro-Machined Bulk PZT

    Directory of Open Access Journals (Sweden)

    Zhe Wang

    2015-01-01

    Full Text Available This paper proposes a novel flexible piezoelectric micro-machined ultrasound transducer, which is based on PZT and a polyimide substrate. The transducer is made on the polyimide substrate and packaged with medical polydimethylsiloxane. Instead of etching the PZT ceramic, this paper proposes a method of putting diced PZT blocks into holes on the polyimide which are pre-etched. The device works in d31 mode and the electromechanical coupling factor is 22.25%. Its flexibility, good conformal contacting with skin surfaces and proper resonant frequency make the device suitable for heart imaging. The flexible packaging ultrasound transducer also has a good waterproof performance after hundreds of ultrasonic electric tests in water. It is a promising ultrasound transducer and will be an effective supplementary ultrasound imaging method in the practical applications.

  10. Ultrasonic fingerprint sensor using a piezoelectric micromachined ultrasonic transducer array integrated with complementary metal oxide semiconductor electronics

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Y.; Fung, S.; Wang, Q.; Horsley, D. A. [Berkeley Sensor and Actuator Center, University of California, Davis, 1 Shields Avenue, Davis, California 95616 (United States); Tang, H.; Boser, B. E. [Berkeley Sensor and Actuator Center, University of California, Berkeley, California 94720 (United States); Tsai, J. M.; Daneman, M. [InvenSense, Inc., 1745 Technology Drive, San Jose, California 95110 (United States)

    2015-06-29

    This paper presents an ultrasonic fingerprint sensor based on a 24 × 8 array of 22 MHz piezoelectric micromachined ultrasonic transducers (PMUTs) with 100 μm pitch, fully integrated with 180 nm complementary metal oxide semiconductor (CMOS) circuitry through eutectic wafer bonding. Each PMUT is directly bonded to a dedicated CMOS receive amplifier, minimizing electrical parasitics and eliminating the need for through-silicon vias. The array frequency response and vibration mode-shape were characterized using laser Doppler vibrometry and verified via finite element method simulation. The array's acoustic output was measured using a hydrophone to be ∼14 kPa with a 28 V input, in reasonable agreement with predication from analytical calculation. Pulse-echo imaging of a 1D steel grating is demonstrated using electronic scanning of a 20 × 8 sub-array, resulting in 300 mV maximum received amplitude and 5:1 contrast ratio. Because the small size of this array limits the maximum image size, mechanical scanning was used to image a 2D polydimethylsiloxane fingerprint phantom (10 mm × 8 mm) at a 1.2 mm distance from the array.

  11. Two-dimensional capacitive micromachined ultrasonic transducer (CMUT) arrays for a miniature integrated volumetric ultrasonic imaging system

    Science.gov (United States)

    Zhuang, Xuefeng; Wygant, Ira O.; Yeh, David T.; Nikoozadeh, Amin; Oralkan, Omer; Ergun, Arif S.; Cheng, Ching-Hsiang; Huang, Yongli; Yaralioglu, Goksen G.; Khuri-Yakub, Butrus T.

    2005-04-01

    We have designed, fabricated, and characterized two-dimensional 16x16-element capacitive micromachined ultrasonic transducer (CMUT) arrays. The CMUT array elements have a 250-μm pitch, and when tested in immersion, have a 5 MHz center frequency and 99% fractional bandwidth. The fabrication process is based on standard silicon micromachining techniques and therefore has the advantages of high yield, low cost, and ease of integration. The transducers have a Si3N4 membrane and are fabricated on a 400-μm thick silicon substrate. A low parasitic capacitance through-wafer via connects each CMUT element to a flip-chip bond pad on the back side of the wafer. Each through wafer via is 20 μm in diameter and 400 μm deep. The interconnects form metal-insulator-semiconductor (MIS) junctions with the surrounding high-resistivity silicon substrate to establish isolation and to reduce parasitic capacitance. Each through-wafer via has less than 0.06 pF of parasitic capacitance. We have investigated a Au-In flip-chip bonding process to connect the 2D CMUT array to a custom integrated circuit (IC) with transmit and receive electronics. To develop this process, we fabricated fanout structures on silicon, and flip-chip bonded these test dies to a flat surface coated with gold. The average series resistance per bump is about 3 Ohms, and 100% yield is obtained for a total of 30 bumps.

  12. An investigation of various shading (window) functions by printing the shape of the function on underwater transmitting transducers and arrays

    Science.gov (United States)

    Nicolaides, K.; Nortman, L.

    2012-05-01

    In any sonar system, suppression of the side lobes results in an increase in main beam to side lobe level (signal to noise) ratio, with a consequence in an increase in detection range and resolution. Traditionally, this undertaking is done as part of the signal processing operation of the array. The overall aim of this paper is to investigate the advantages and disadvantages of implementing various shading functions directly on the radiating surface of the individual elements (transducers) of a line array. In particular, this paper examines the performance of various shading (window) functions, such as rectangular, cosine, triangular, Hamming, and Blackman-Harris, by printing the actual shape of the function on a transmitting multi-element line array. The transducers used are of 1-3 piezocomposite material with acoustic window and operate at 300 kHz with over 100 kHz of bandwidth. The results of the acoustic tests and polar (directivity) responses are presented and compared to theoretical simulations. The results obtained show that significant improvement of the main beam to side lobe level ratio can be achieved with an unfortunate widening of the main beam.

  13. Multi-view Hilbert transformation in full-ring-transducer-array based photoacoustic computed tomography (Conference Presentation)

    Science.gov (United States)

    Li, Lei; Li, Guo; Zhu, Liren; Xia, Jun; Wang, Lihong V.

    2016-03-01

    Photoacoustic tomography (PAT) exploits optical contrast and ultrasonic detection principles to form images of absorbed optical energy density within tissue. Based on the photoacoustic effect, PAT directly and quantitatively measures specific optical absorption. A full-ring ultrasonic transducer array based photoacoustic computed tomography (PACT) system was recently developed for small animal whole-body imaging with a full-view detection angle and high in-plane resolution (100 µm). However, due to the band-pass frequency response of the piezoelectric transducer elements, the reconstructed images present bipolar (both positive and negative) pixel values, which is artificial and counterintuitive for physicians and biologists seeking to interpret the image. Moreover, bipolar pixel values hinder quantification of physiological parameters, such as oxygen saturation and blood flow speed. Unipolar images can be obtained by deconvolving the raw channel data with the transducer's electrical impulse response and applying non-negativity during iteration, but this process requires complex transducer modeling and time-consuming computation. Here, we present a multi-view Hilbert transformation method to recover the unipolar initial pressure for full-ring PACT. Multi-view Hilbert transformation along the acoustic wave propagation direction minimizes reconstruction artifacts during envelope extraction and maintains the signal-to-noise ratio of the reconstructed images. The in-plane isotropic spatial resolution of this method was quantified to 168 μm within a 20 × 20 mm2 field of view. The effectiveness of the proposed algorithm was first validated by numerical simulations and then demonstrated with ex-vivo mouse brain structural imaging and in-vivo mouse wholebody imaging.

  14. High Performance Relaxor-Based Ferroelectric Single Crystals for Ultrasonic Transducer Applications

    Directory of Open Access Journals (Sweden)

    Yan Chen

    2014-07-01

    Full Text Available Relaxor-based ferroelectric single crystals Pb(Mg1/3Nb2/3O3-PbTiO3 (PMN-PT have drawn much attention in the ferroelectric field because of their excellent piezoelectric properties and high electromechanical coupling coefficients (d33~2000 pC/N, kt~60% near the morphotropic phase boundary (MPB. Ternary Pb(In1/2Nb1/2O3-Pb(Mg1/3Nb2/3O3-PbTiO3 (PIN-PMN-PT single crystals also possess outstanding performance comparable with PMN-PT single crystals, but have higher phase transition temperatures (rhombohedral to tetragonal Trt, and tetragonal to cubic Tc and larger coercive field Ec. Therefore, these relaxor-based single crystals have been extensively employed for ultrasonic transducer applications. In this paper, an overview of our work and perspectives on using PMN-PT and PIN-PMN-PT single crystals for ultrasonic transducer applications is presented. Various types of single-element ultrasonic transducers, including endoscopic transducers, intravascular transducers, high-frequency and high-temperature transducers fabricated using the PMN-PT and PIN-PMN-PT crystals and their 2-2 and 1-3 composites are reported. Besides, the fabrication and characterization of the array transducers, such as phased array, cylindrical shaped linear array, high-temperature linear array, radial endoscopic array, and annular array, are also addressed.

  15. Frequency division multiple transmission method to utilize the wide bandwidth property of capacitive micromachined ultrasonic transducer arrays

    Science.gov (United States)

    Lee, Seunghun; Kim, Bae-Hyung; Jeon, Taeho; Kim, Youngil; Cho, Kyungil; Song, Jongkeun

    2013-03-01

    CMUT-on-ASIC integration techniques are promising for the development of lower cost smaller volume scanners with higher performance in terms of features and image qualities because it minimizes parasitic capacitances and ultimately improves signal-to-noise ratio (SNR). Moreover, a frequency bandwidth of CMUT array is known as relatively broader than that of other ultrasonic transducer arrays. To utilize the wide bandwidth characteristic of the CMUT arrays, in this paper, we introduce a FDMA (frequency division multiple access) based ultrasound imaging technique using orthogonally band-divided coded signals to provide dynamic transmit focused imaging without sacrificing the frame rate. In the presented method, the orthogonal sub-band coded signals are simultaneously fired on multiple ranges, in which each signal is focused at a different range, in one transmission event. This paper also presents an ultrasound imageformation method and a modulation and demodulation process of orthogonal sub-band coded signals designed within the frequency bandwidth of the CMUT arrays. The presented method is verified by computer simulations using Field II and experiments. The simulation results using a computer generated tissue mimicking phantom show that the presented method can be achieved with both increased image quality and frame rate. The experimental results to verify the feasibility of the presented method using orthogonal sub-band coded signals show that the reflected signals from targets are successfully separated into two compressed signals. Currently, we are extending the presented approach to ultrasound imaging technique for volumetric ultrasound scanners using 2-D CMUT-on-ASIC arrays.

  16. Large Volume Coagulation Utilizing Multiple Cavitation Clouds Generated by Array Transducer Driven by 32 Channel Drive Circuits

    Science.gov (United States)

    Nakamura, Kotaro; Asai, Ayumu; Sasaki, Hiroshi; Yoshizawa, Shin; Umemura, Shin-ichiro

    2013-07-01

    High-intensity focused ultrasound (HIFU) treatment is a noninvasive treatment, in which focused ultrasound is generated outside the body and coagulates a diseased tissue. The advantage of this method is minimal physical and mental stress to the patient, and the disadvantage is the long treatment time caused by the smallness of the therapeutic volume by a single exposure. To improve the efficiency and shorten the treatment time, we are focusing attention on utilizing cavitation bubbles. The generated microbubbles can convert the acoustic energy into heat with a high efficiency. In this study, using the class D amplifiers, which we have developed, to drive the array transducer, we demonstrate a new method to coagulate a large volume by a single HIFU exposure through generating cavitation bubbles distributing in a large volume and vibrating all of them. As a result, the coagulated volume by the proposed method was 1.71 times as large as that of the conventional method.

  17. Normal Mode Theory Applied to Linear Arrays of Capacitive Micromachined Ultrasonic Transducers

    Science.gov (United States)

    Boulmé, Audren; Gross, Dominique; Heller, Jacques; Certon, Domnique

    This paper describes the implementation of a new equivalent electroacoustic circuit for cMUT arrays. This circuit was obtained by using the normal mode theory. Theoretical simulations were also carried out from this new circuit to illustrate the impact of the trapped modes and some properties of the fundamental mode.

  18. Sound field separation with a double layer velocity transducer array (L)

    DEFF Research Database (Denmark)

    Fernandez Grande, Efren; Jacobsen, Finn

    2011-01-01

    of the array. The technique has been examined and compared with direct velocity based reconstruction, as well as with a technique based on the measurement of the sound pressure and particle velocity. The double layer velocity method circumvents some of the drawbacks of the pressure-velocity based...

  19. First in vivo use of a capacitive micromachined ultrasound transducer array-based imaging and ablation catheter.

    Science.gov (United States)

    Stephens, Douglas N; Truong, Uyen T; Nikoozadeh, Amin; Oralkan, Omer; Seo, Chi Hyung; Cannata, Jonathan; Dentinger, Aaron; Thomenius, Kai; de la Rama, Alan; Nguyen, Tho; Lin, Feng; Khuri-Yakub, Pierre; Mahajan, Aman; Shivkumar, Kalyanam; O'Donnell, Matt; Sahn, David J

    2012-02-01

    The primary objective was to test in vivo for the first time the general operation of a new multifunctional intracardiac echocardiography (ICE) catheter constructed with a microlinear capacitive micromachined ultrasound transducer (ML-CMUT) imaging array. Secondarily, we examined the compatibility of this catheter with electroanatomic mapping (EAM) guidance and also as a radiofrequency ablation (RFA) catheter. Preliminary thermal strain imaging (TSI)-derived temperature data were obtained from within the endocardium simultaneously during RFA to show the feasibility of direct ablation guidance procedures. The new 9F forward-looking ICE catheter was constructed with 3 complementary technologies: a CMUT imaging array with a custom electronic array buffer, catheter surface electrodes for EAM guidance, and a special ablation tip, that permits simultaneous TSI and RFA. In vivo imaging studies of 5 anesthetized porcine models with 5 CMUT catheters were performed. The ML-CMUT ICE catheter provided high-resolution real-time wideband 2-dimensional (2D) images at greater than 8 MHz and is capable of both RFA and EAM guidance. Although the 24-element array aperture dimension is only 1.5 mm, the imaging depth of penetration is greater than 30 mm. The specially designed ultrasound-compatible metalized plastic tip allowed simultaneous imaging during ablation and direct acquisition of TSI data for tissue ablation temperatures. Postprocessing analysis showed a first-order correlation between TSI and temperature, permitting early development temperature-time relationships at specific myocardial ablation sites. Multifunctional forward-looking ML-CMUT ICE catheters, with simultaneous intracardiac guidance, ultrasound imaging, and RFA, may offer a new means to improve interventional ablation procedures.

  20. A Front-End ASIC with Receive Sub-array Beamforming Integrated with a 32 × 32 PZT Matrix Transducer for 3-D Transesophageal Echocardiography

    NARCIS (Netherlands)

    Chen, C.; Chen, Z.; Bera, Deep; Raghunathan, S.B.; ShabaniMotlagh, M.; Noothout, E.C.; Chang, Z.Y.; Ponte, Jacco; Prins, Christian; Vos, H.J.; Bosch, Johan G.; Verweij, M.D.; de Jong, N.; Pertijs, M.A.P.

    2017-01-01

    This paper presents a power-and area-efficient front-end application-specific integrated circuit (ASIC) that is directly integrated with an array of 32 × 32 piezoelectric transducer elements to enable next-generation miniature ultrasound probes for real-time 3-D transesophageal echocardiography.

  1. NovoTTF™-100A System (Tumor Treating Fields) transducer array layout planning for glioblastoma: a NovoTAL™ system user study.

    Science.gov (United States)

    Chaudhry, Aafia; Benson, Laura; Varshaver, Michael; Farber, Ori; Weinberg, Uri; Kirson, Eilon; Palti, Yoram

    2015-11-11

    Optune™, previously known as the NovoTTF-100A System™, generates Tumor Treating Fields (TTFields), an effective anti-mitotic therapy for glioblastoma. The system delivers intermediate frequency, alternating electric fields to the supratentorial brain. Patient therapy is personalized by configuring transducer array layout placement on the scalp to the tumor site using MRI measurements and the NovoTAL System. Transducer array layout mapping optimizes therapy by maximizing electric field intensity to the tumor site. This study evaluated physician performance in conducting transducer array layout mapping using the NovoTAL System compared with mapping performed by the Novocure in-house clinical team. Fourteen physicians (7 neuro-oncologists, 4 medical oncologists, and 3 neurosurgeons) evaluated five blinded cases of recurrent glioblastoma and performed head size and tumor location measurements using a standard Digital Imaging and Communications in Medicine reader. Concordance with Novocure measurement and intra- and inter-rater reliability were assessed using relevant correlation coefficients. The study criterion for success was a concordance correlation coefficient (CCC) >0.80. CCC for each physician versus Novocure on 20 MRI measurements was 0.96 (standard deviation, SD ± 0.03, range 0.90-1.00), indicating very high agreement between the two groups. Intra- and inter-rater reliability correlation coefficients were similarly high: 0.83 (SD ±0.15, range 0.54-1.00) and 0.80 (SD ±0.18, range 0.48-1.00), respectively. This user study demonstrated an excellent level of concordance between prescribing physicians and Novocure in-house clinical teams in performing transducer array layout planning. Intra-rater reliability was very high, indicating reproducible performance. Physicians prescribing TTFields, when trained on the NovoTAL System, can independently perform transducer array layout mapping required for the initiation and maintenance of patients on TTFields

  2. Crack Orientation and Depth Estimation in a Low-Pressure Turbine Disc Using a Phased Array Ultrasonic Transducer and an Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Wenshuang Chang

    2013-09-01

    Full Text Available Stress corrosion cracks (SCC in low-pressure steam turbine discs are serious hidden dangers to production safety in the power plants, and knowing the orientation and depth of the initial cracks is essential for the evaluation of the crack growth rate, propagation direction and working life of the turbine disc. In this paper, a method based on phased array ultrasonic transducer and artificial neural network (ANN, is proposed to estimate both the depth and orientation of initial cracks in the turbine discs. Echo signals from cracks with different depths and orientations were collected by a phased array ultrasonic transducer, and the feature vectors were extracted by wavelet packet, fractal technology and peak amplitude methods. The radial basis function (RBF neural network was investigated and used in this application. The final results demonstrated that the method presented was efficient in crack estimation tasks.

  3. Crack orientation and depth estimation in a low-pressure turbine disc using a phased array ultrasonic transducer and an artificial neural network.

    Science.gov (United States)

    Yang, Xiaoxia; Chen, Shili; Jin, Shijiu; Chang, Wenshuang

    2013-09-13

    Stress corrosion cracks (SCC) in low-pressure steam turbine discs are serious hidden dangers to production safety in the power plants, and knowing the orientation and depth of the initial cracks is essential for the evaluation of the crack growth rate, propagation direction and working life of the turbine disc. In this paper, a method based on phased array ultrasonic transducer and artificial neural network (ANN), is proposed to estimate both the depth and orientation of initial cracks in the turbine discs. Echo signals from cracks with different depths and orientations were collected by a phased array ultrasonic transducer, and the feature vectors were extracted by wavelet packet, fractal technology and peak amplitude methods. The radial basis function (RBF) neural network was investigated and used in this application. The final results demonstrated that the method presented was efficient in crack estimation tasks.

  4. Forward-viewing CMUT arrays for medical imaging.

    Science.gov (United States)

    Demirci, Utkan; Ergun, Arif S; Oralkan, Omrer; Karaman, Mustafa; Khuri-Yakub, Butrus T

    2004-07-01

    This paper reports the design and testing of forward-viewing annular arrays fabricated using capacitive micromachined ultrasonic transducer (CMUT) technology. Recent research studies have shown that CMUTs have broad frequency bandwidth and high-transduction efficiency. One- and two-dimensional CMUT arrays of various sizes already have been fabricated, and their viability for medical imaging applications has been demonstrated. We fabricated 64-element, forward-viewing annular arrays using the standard CMUT fabrication process and carried out experiments to measure the operating frequency, bandwidth, and transmit/receive efficiency of the array elements. The annular array elements, designed for imaging applications in the 20 MHz range, had a resonance frequency of 13.5 MHz in air. The immersion pulse-echo data collected from a plane reflector showed that the devices operate in the 5-26 MHz range with a fractional bandwidth of 135%. The output pressure at the surface of the transducer was measured to be 24 kPa/V. These values translate into a dynamic range of 131.5 dB for 1-V excitation in 1-Hz bandwidth with a commercial low noise receiving circuitry. The designed, forward-viewing annular CMUT array is suitable for mounting on the front surface of a cylindrical catheter probe and can provide Doppler information for measurement of blood flow and guiding information for navigation through blood vessels in intravascular ultrasound imaging.

  5. A comparison between conventional and collapse-mode capacitive micromachined ultrasonic transducers in 10-MHz 1-D arrays.

    Science.gov (United States)

    Park, Kwan Kyu; Oralkan, Omer; Khuri-Yakub, Butrus T

    2013-06-01

    This paper presents a comprehensive comparison between a collapse-mode and a conventional-mode capacitive micromachined ultrasonic transducer (CMUT); both devices have a 1-μm-thick silicon plate and operate at 10 MHz when biased at 100 V. The radii of the circular plates and the gap heights are modified to meet the design specifications required for a fair comparison. Finite element analysis (FEA) shows that the collapse-mode CMUT has higher output pressure sensitivity (46.5 kPa/V) than the conventional CMUT (13.1 kPa/V), and achieves a 3-dB fractional bandwidth (FBW) of 124% compared with 128% for the conventional mode. These results were validated by experiments performed on devices fabricated in a 1-D phased array configuration using the local oxidation of silicon (LOCOS)/wafer-bonding process. The measured output pressure sensitivity and the FBW of the collapse-mode and the conventional CMUTs at 100 V were 26.4 kPa/V and 103% and 12.7 kPa/V and 111%, respectively. The maximum output pressure of the collapse-mode CMUT was 1.19 MPa at 10 MHz, which was much higher than the conventional CMUT (0.44 MPa). However, the second harmonic distortion (SHD) level of the collapse-mode CMUT is higher than the conventional CMUT at the same excitation condition. Even with higher electric field in the cavity, the collapse-mode CMUT was as stable as the conventional CMUT in a long-term test. A 30-h test with a total of 3.2 × 10(9) cycles of 30 V ac excitation resulted in no significant degradation in the performance of the collapse-mode devices.

  6. Numerical simulations of annular wire-array z-pinches in (x,y), (r,θ), and (r,z) geometries

    International Nuclear Information System (INIS)

    Marder, B.M.; Sanford, T.W.L.; Allshouse, G.O.

    1997-12-01

    The Total Immersion PIC (TIP) code has been used in several two-dimensional geometries to understand better the measured dynamics of annular, aluminum wire-array z-pinches. The areas investigated include the formation of the plasma sheath from current-induced individual wire explosions, the effects of wire number and symmetry on the implosion dynamics, and the dependence of the Rayleigh-Taylor instability growth on initial sheath thickness. A qualitative change in the dynamics with increasing wire number was observed, corresponding to a transition between a z-pinch composed of non-merging, self-pinching individual wires, and one characterized by the rapid formation and subsequent implosion of a continuous plasma sheath. A sharp increase in radiated power with increasing wire number has been observed experimentally near this calculated transition. Although two-dimensional codes have correctly simulated observed power pulse durations, there are indications that three dimensional effects are important in understanding the actual mechanism by which these pulse lengths are produced

  7. Objective assessment and design improvement of a staring, sparse transducer array by the spatial crosstalk matrix for 3D photoacoustic tomography.

    Directory of Open Access Journals (Sweden)

    Philip Wong

    Full Text Available Accurate reconstruction of 3D photoacoustic (PA images requires detection of photoacoustic signals from many angles. Several groups have adopted staring ultrasound arrays, but assessment of array performance has been limited. We previously reported on a method to calibrate a 3D PA tomography (PAT staring array system and analyze system performance using singular value decomposition (SVD. The developed SVD metric, however, was impractical for large system matrices, which are typical of 3D PAT problems. The present study consisted of two main objectives. The first objective aimed to introduce the crosstalk matrix concept to the field of PAT for system design. Figures-of-merit utilized in this study were root mean square error, peak signal-to-noise ratio, mean absolute error, and a three dimensional structural similarity index, which were derived between the normalized spatial crosstalk matrix and the identity matrix. The applicability of this approach for 3D PAT was validated by observing the response of the figures-of-merit in relation to well-understood PAT sampling characteristics (i.e. spatial and temporal sampling rate. The second objective aimed to utilize the figures-of-merit to characterize and improve the performance of a near-spherical staring array design. Transducer arrangement, array radius, and array angular coverage were the design parameters examined. We observed that the performance of a 129-element staring transducer array for 3D PAT could be improved by selection of optimal values of the design parameters. The results suggested that this formulation could be used to objectively characterize 3D PAT system performance and would enable the development of efficient strategies for system design optimization.

  8. 4D ICE: A 2D Array Transducer with Integrated ASIC in a 10 Fr Catheter for Real-Time 3D Intracardiac Echocardiography.

    Science.gov (United States)

    Wildes, Douglas; Lee, Warren; Haider, Bruno; Cogan, Scott; Sundaresan, Krishnakumar; Mills, David; Yetter, Christopher; Hart, Patrick; Haun, Christopher; Concepcion, Mikael; Kirkhorn, Johan; Bitoun, Marc

    2016-10-12

    We developed a 2.5 x 6.6 mm 2D array transducer with integrated transmit/receive ASIC for 4D ICE (real-time 3D IntraCardiac Echocardiography) applications. The ASIC and transducer design were optimized so that the high voltage transmit, low-voltage TGC (time-gain control) and preamp, subaperture beamformer, and digital control circuits for each transducer element all fit within the 0.019 mm2 area of the element. The transducer assembly was deployed in a 10 Fr (3.3 mm diameter) catheter, integrated with a GE Vivid1 E9 ultrasound imaging system, and evaluated in three pre-clinical studies. 2D image quality and imaging modes were comparable to commercial 2D ICE catheters. The 4D field of view was at least 90° x 60° x 8 cm and could be imaged at 30 volumes/sec, sufficient to visualize cardiac anatomy and other diagnostic and therapy catheters. 4D ICE should significantly reduce X-ray fluoroscopy use and dose during electrophysiology (EP) ablation procedures. 4D ICE may be able to replace trans-esophageal echocardiography (TEE), and the associated risks and costs of general anesthesia, for guidance of some structural heart procedures.

  9. 4-D ICE: A 2-D Array Transducer With Integrated ASIC in a 10-Fr Catheter for Real-Time 3-D Intracardiac Echocardiography.

    Science.gov (United States)

    Wildes, Douglas; Lee, Warren; Haider, Bruno; Cogan, Scott; Sundaresan, Krishnakumar; Mills, David M; Yetter, Christopher; Hart, Patrick H; Haun, Christopher R; Concepcion, Mikael; Kirkhorn, Johan; Bitoun, Marc

    2016-12-01

    We developed a 2.5 ×6.6 mm 2 2 -D array transducer with integrated transmit/receive application-specific integrated circuit (ASIC) for real-time 3-D intracardiac echocardiography (4-D ICE) applications. The ASIC and transducer design were optimized so that the high-voltage transmit, low-voltage time-gain control and preamp, subaperture beamformer, and digital control circuits for each transducer element all fit within the 0.019-mm 2 area of the element. The transducer assembly was deployed in a 10-Fr (3.3-mm diameter) catheter, integrated with a GE Vivid E9 ultrasound imaging system, and evaluated in three preclinical studies. The 2-D image quality and imaging modes were comparable to commercial 2-D ICE catheters. The 4-D field of view was at least 90 ° ×60 ° ×8 cm and could be imaged at 30 vol/s, sufficient to visualize cardiac anatomy and other diagnostic and therapy catheters. 4-D ICE should significantly reduce X-ray fluoroscopy use and dose during electrophysiology ablation procedures. 4-D ICE may be able to replace transesophageal echocardiography (TEE), and the associated risks and costs of general anesthesia, for guidance of some structural heart procedures.

  10. Chemometric Classification of Unknown Vapors by Conversion of Sensor Array Pattern Vectors to Vapor Descriptors: Extension from Mass-Transducing Sensors To Volume-Transducing Sensors

    Energy Technology Data Exchange (ETDEWEB)

    Grate, Jay W.; Wise, Barry M.

    2001-06-28

    A new chemometric method was recently described for classifying unknowns by transforming the vector containing the responses from a multivariate detector to a vector containing descriptors of the detected analyte (Grate et al. 1999). This approach was derived for sensor arrays where each sensor's signal is proportional to the amount of vapor sorbed by a polymer on the sensor surface. In this case, the response is proportional to the partition coefficient, K, and the concentration of the vapor in the gas phase, Cv, where K is the ratio of the concentration of vapor in the sorbent polymer phase, Cs, to Cv.

  11. 3-D Ultrasound Imaging Performance of a Row-Column Addressed 2-D Array Transducer: A Measurement Study

    DEFF Research Database (Denmark)

    Rasmussen, Morten Fischer; Jensen, Jørgen Arendt

    2013-01-01

    -lobe levels are higher for the row-column addressed array. The cystic resolution sampled at a relative intensity difference of 20 dB shows a cyst size of 5.00mm for the row-column addressed array and 2.39mm for the fully sampled array. A simulation study is carried out which compares how the imaging quality...... is 510% larger than when row-column addressing the array. The cyst radius needed to achieve -20 dB intensity in the cyst is 396% larger for the fully addressed array compared to the row-column addressed array. The measurements were made using the experimental ultrasound scanner SARUS and a 32x32 element...

  12. Evaluation of bias voltage modulation sequence for nonlinear contrast agent imaging using a capacitive micromachined ultrasonic transducer array

    Science.gov (United States)

    Novell, Anthony; Legros, Mathieu; Grégoire, Jean-Marc; Dayton, Paul A.; Bouakaz, Ayache

    2014-09-01

    Many clinical diagnoses have now been improved thanks to the development of new techniques dedicated to contrast agent nonlinear imaging. Over the past few years, Capacitive Micromachined Ultrasonic Transducers (cMUTs) have emerged as a promising alternative to traditional piezoelectric transducers. One notable advantage of cMUTs is their wide frequency bandwidth. However, their use in nonlinear imaging approaches such as those used to detect contrast agents have been challenging due their intrinsic nonlinear character. We propose a new contrast imaging sequence, called bias voltage modulation (BVM), specifically developed for cMUTs to suppress their inherent nonlinear behavior. Theoretical and experimental results show that a complete cancellation of the nonlinear signal from the source can be reached when the BVM sequence is implemented. In-vitro validation of the sequence is performed using a cMUT probe connected to an open scanner and a flow phantom setup containing SonoVue microbubbles. Compared to the standard amplitude modulation imaging mode, a 6 dB increase of contrast-to-tissue ratio was achieved when the BVM sequence is applied. These results reveal that the problem of cMUT nonlinearity can be addressed, thus expanding the potential of this new transducer technology for nonlinear contrast agent detection and imaging.

  13. Evaluation of bias voltage modulation sequence for nonlinear contrast agent imaging using a capacitive micromachined ultrasonic transducer array

    International Nuclear Information System (INIS)

    Novell, Anthony; Grégoire, Jean-Marc; Bouakaz, Ayache; Legros, Mathieu; Dayton, Paul A

    2014-01-01

    Many clinical diagnoses have now been improved thanks to the development of new techniques dedicated to contrast agent nonlinear imaging. Over the past few years, Capacitive Micromachined Ultrasonic Transducers (cMUTs) have emerged as a promising alternative to traditional piezoelectric transducers. One notable advantage of cMUTs is their wide frequency bandwidth. However, their use in nonlinear imaging approaches such as those used to detect contrast agents have been challenging due their intrinsic nonlinear character. We propose a new contrast imaging sequence, called bias voltage modulation (BVM), specifically developed for cMUTs to suppress their inherent nonlinear behavior. Theoretical and experimental results show that a complete cancellation of the nonlinear signal from the source can be reached when the BVM sequence is implemented. In-vitro validation of the sequence is performed using a cMUT probe connected to an open scanner and a flow phantom setup containing SonoVue microbubbles. Compared to the standard amplitude modulation imaging mode, a 6 dB increase of contrast-to-tissue ratio was achieved when the BVM sequence is applied. These results reveal that the problem of cMUT nonlinearity can be addressed, thus expanding the potential of this new transducer technology for nonlinear contrast agent detection and imaging. (paper)

  14. 3D ultrasound imaging performance of a row-column addressed 2D array transducer: a simulation study

    DEFF Research Database (Denmark)

    Rasmussen, Morten Fischer; Jensen, Jørgen Arendt

    2013-01-01

    This paper compares the imaging performance of a 128+128 element row-column addressed array with a fully addressed 1616 2D array. The comparison is made via simulations of the point spread function with Field II. Both arrays have lambda-pitch, a center frequency of 3:5MHz and use 256 active...... elements. The row-column addressed array uses 128 transmit channels and 128 receive channels, whereas the fully addressed array uses 256 channels in both transmit and receive. The large size of the emulated row and column elements in the row-column addressed array causes ghost echoes to appear. The ghost...... echoes are shown to be suppressed when the sub-elements within each of the emulated row and column elements are apodized. The maximum ghost intensity is suppressed by 22:2 dB compared to using no apodization. With apodization applied, the full-width-at-half-maximum in the lateral direction for the fully...

  15. Efficient broadband simulation of fluid-structure coupling for membrane-type acoustic transducer arrays using the multi-level fast multipole algorithm

    Science.gov (United States)

    Shieh, Bernard; Sabra, Karim; Degertekin, F. Levent

    2016-01-01

    A boundary element model provides great flexibility for the simulation of membrane-type micromachined ultrasonic transducers (MUTs) in terms of membrane shape, actuating mechanism, and array layout. Acoustic crosstalk is accounted for through a mutual impedance matrix which captures the primary crosstalk mechanism of dispersive-guided modes generated at the fluid-solid interface. However, finding the solution to the fully-populated boundary element matrix equation using standard techniques requires computation time and memory usage which scales by the cube and by the square of the number of nodes, respectively, limiting simulation to a small number of membranes. We implement a solver with improved speed and efficiency through the application of a multi-level fast multipole algorithm (FMA). By approximating the fields of collections of nodes using multipole expansions of the free-space Green’s function, an FMA solver can enable the simulation of hundreds of thousands of nodes while incurring an approximation error that is controllable. Convergence is drastically improved using a problem-specific block-diagonal preconditioner. We demonstrate the solver’s capabilities by simulating a 32-element 7 MHz 1-D CMUT phased array with 2880 membranes. The array is simulated using 233,280 nodes for a very wide frequency band up to 50 MHz. For a simulation with 15,210 nodes, the FMA solver performed 10-times faster and used 32-times less memory than a standard solver based on LU decomposition We investigate the effects of mesh density and phasing on the predicted array response and find that it is necessary to use about 7 nodes over the width of the membrane to observe convergence of the solution–even below the first membrane resonance frequency–due to the influence of higher-order membrane modes. PMID:27824572

  16. Annular Flow Distribution test

    Energy Technology Data Exchange (ETDEWEB)

    Kielpinski, A.L. (ed.) (Westinghouse Savannah River Co., Aiken, SC (United States)); Childerson, M.T.; Knoll, K.E.; Manolescu, M.I.; Reed, M.J. (Babcock and Wilcox Co., Alliance, OH (United States). Research Center)

    1990-12-01

    This report documents the Babcock and Wilcox (B W) Annular Flow Distribution testing for the Savannah River Laboratory (SRL). The objective of the Annular Flow Distribution Test Program is to characterize the flow distribution between annular coolant channels for the Mark-22 fuel assembly with the bottom fitting insert (BFI) in place. Flow rate measurements for each annular channel were obtained by establishing hydraulic similarity'' between an instrumented fuel assembly with the BFI removed and a reference'' fuel assembly with the BFI installed. Empirical correlations of annular flow rates were generated for a range of boundary conditions.

  17. Annular Flow Distribution test

    International Nuclear Information System (INIS)

    Kielpinski, A.L.; Childerson, M.T.; Knoll, K.E.; Manolescu, M.I.; Reed, M.J.

    1990-12-01

    This report documents the Babcock and Wilcox (B ampersand W) Annular Flow Distribution testing for the Savannah River Laboratory (SRL). The objective of the Annular Flow Distribution Test Program is to characterize the flow distribution between annular coolant channels for the Mark-22 fuel assembly with the bottom fitting insert (BFI) in place. Flow rate measurements for each annular channel were obtained by establishing ''hydraulic similarity'' between an instrumented fuel assembly with the BFI removed and a ''reference'' fuel assembly with the BFI installed. Empirical correlations of annular flow rates were generated for a range of boundary conditions

  18. Micromachined Ultrasonic Transducers for 3-D Imaging

    DEFF Research Database (Denmark)

    Christiansen, Thomas Lehrmann

    of state-of-the-art 3-D ultrasound systems. The focus is on row-column addressed transducer arrays. This previously sparsely investigated addressing scheme offers a highly reduced number of transducer elements, resulting in reduced transducer manufacturing costs and data processing. To produce...... such transducer arrays, capacitive micromachined ultrasonic transducer (CMUT) technology is chosen for this project. Properties such as high bandwidth and high design flexibility makes this an attractive transducer technology, which is under continuous development in the research community. A theoretical...... capable of producing 62+62-element row-column addressed CMUT arrays with negligible charging issues. The arrays include an integrated apodization, which reduces the ghost echoes produced by the edge waves in such arrays by 15:8 dB. The acoustical cross-talk is measured on fabricated arrays, showing a 24 d...

  19. Applying of the array transducers' technology for surface acoustic waves materials characterization in the transient regime; Application de la technologie multi-elements a la caracterisation des materiaux par ondes acoustiques de surface en regime impulsionnel

    Energy Technology Data Exchange (ETDEWEB)

    Frenet, D

    2000-07-01

    In this document we present a theoretical and experimental study which has been led to design a surface acoustic wave device for local characterisation (relatively to the wavelength) of isotropic or anisotropic materials. The device is based on a phased-array transducer of conical shape we have specifically designed for this purpose. It operates in the impulsive mode, in the frequency range of 1-5 MHz. In order to deduce mechanical properties of the material, it is possible to measure the surface wave characteristics (velocity, attenuation,...). Different methods for measuring the wave velocity have been developed taking advantage of from the phased-array technology. The originality of theses methods relies on the fact that the measures are performed without moving the transducer. Consequently, the device requires no additional mechanical system and it is quite compact. In addition, this shortens the characterisation process duration comparatively to the usually available methods (e. g. the V(z) technique). In the theoretical section of this study, a versatile model allowing to simulate in the time harmonic regime as well as in the transient regime, the transmitted field, the field reflected on isotropic or anisotropic planar samples and the output voltage for transducers of arbitrary shapes has been developed. The model has been applied to the phased-array conical transducer as well as to more classical transducers such as planar (rectangular) or focusing (spherically or cylindrically shaped) transducers. It predicts not only the geometrical contributions of the reflected field and signal but also the leaky contributions related to the surface acoustic waves. (author)

  20. Familial Granuloma Annulare

    Directory of Open Access Journals (Sweden)

    Zennure Takci

    2015-09-01

    Full Text Available Granuloma annulare is a benign, asymptomatic, relatively common, often self-limited chronic granulomatos disorder of the skin that can affect both children and adults. The primary skin lesion usually is grouped papules in an enlarging annular shape, with color ranging from flesh-colored to erythematous. The two most common types of granuloma annulare are localized, which typically is found on the lateral or dorsal surfaces of the hands and feet; and disseminated, which is widespread. Rarely, familial cases of granuloma annulare has been reported. Herein, we report two sisters with annular papules and plaques diagnosed as granuloma annulare with the clinical and pathological findings. [J Contemp Med 2015; 5(3.000: 189-191

  1. Microinterferometer transducer

    International Nuclear Information System (INIS)

    Steger, P.J.

    1978-01-01

    An air-bearing microinterferometer transducer is being developed to provide for increased accuracy, range, and linearity over conventional linear variable differential transformer (LVDT) transducers. The conventional LVDT's are used on multiple-probe sweep gauges to measure deviation from true surfaces of revolution. These LVDT transducers are null devices, and their high accuracy deteriorates rapidly as they move from zero setting. It is desirable to have a transducer with extended range to measure parts that deviate from conventional paths. The length-measuring interferometer is a well-established inspection device. However, constructing a microinterferometer that will fit inside a conventional 1/2-in. o.d transducer housing is a formidable task. Departure from the conventional interferometer construction is required. It will be necessary to transmit the laser beam into the microinterferometer with a self-focusing fiber optic cable. Miniature glassware has been obtained and a microinterferometer constructed inside a 0.315-in. i.d transducer. Fringes have been obtained by directing a laser beam into the transducer housing

  2. Coaxial Transducer

    National Research Council Canada - National Science Library

    Ruffa, Anthony A

    2008-01-01

    The invention as disclosed is of a coaxial transducer that uses lead zirconate titanate ceramic or other suitable material as an isolator between the conductors in a coaxial cable to transmit acoustic...

  3. Modeling of ultrasound transducers

    DEFF Research Database (Denmark)

    Bæk, David

    deviation of 5.5 % to 11.0 %. Finite element modeling of piezoceramics in combination with Field II is addressed and reveals the influence of restricting the modeling of transducers to the one-dimensional case. An investigation on modeling capacitive micromachined ultrasonic transducers (CMUT)s with Field...... II is addressed. It is shown how a single circular CMUT cell can be well approximated with a simple square transducer encapsulating the cell, and how this influence the modeling of full array elements. An optimal cell discretization with Field II’s mathematical elements is addressed as well....... The error in modeling CMUT cells as squares or flat circular plates instead of curved circular cells is also addressed....

  4. A single-chip 32-channel analog beamformer with 4-ns delay resolution and 768-ns maximum delay range for ultrasound medical imaging with a linear array transducer.

    Science.gov (United States)

    Um, Ji-Yong; Kim, Yoon-Jee; Cho, Seong-Eun; Chae, Min-Kyun; Kim, Byungsub; Sim, Jae-Yoon; Park, Hong-June

    2015-02-01

    A single-chip 32-channel analog beamformer is proposed. It achieves a delay resolution of 4 ns and a maximum delay range of 768 ns. It has a focal-point based architecture, which consists of 7 sub-analog beamformers (sub-ABF). Each sub-ABF performs a RX focusing operation for a single focal point. Seven sub-ABFs perform a time-interleaving operation to achieve the maximum delay range of 768 ns. Phase interpolators are used in sub-ABFs to generate sampling clocks with the delay resolution of 4 ns from a low frequency system clock of 5 MHz. Each sub-ABF samples 32 echo signals at different times into sampling capacitors, which work as analog memory cells. The sampled 32 echo signals of each sub-ABF are originated from one target focal point at one instance. They are summed at one instance in a sub-ABF to perform the RX focusing for the target focal point. The proposed ABF chip has been fabricated in a 0.13- μ m CMOS process with an active area of 16 mm (2). The total power consumption is 287 mW. In measurement, the digital echo signals from a commercial ultrasound medical imaging machine were applied to the fabricated chip through commercial DAC chips. Due to the speed limitation of the DAC chips, the delay resolution was relaxed to 10 ns for the real-time measurement. A linear array transducer with no steering operation is used in this work.

  5. Transducer fundamentals

    NARCIS (Netherlands)

    Regtien, Paulus P.L.; Sydenham, Peter H.; Thorn, Richard

    2005-01-01

    A transducer is an essential part of any information process- ing system that operates in more than one physical domain. These domains are characterized by the type of quantity that provides the carrier of the relevant information. Exam- ples are the optical, electrical, mechanical, and magnetic

  6. Generalized granuloma annulare

    Directory of Open Access Journals (Sweden)

    Khatri M

    1995-01-01

    Full Text Available A 35-years-old female patient had generalized pruritic papular lesions, distributed like dermatitis herpetiformis for last 4 years. Histopathologic changes were typical of granuloma annulare with negative results of direct immunofluorescence. The patient did not have association of diabetes mellitus or any other systemic disease. She failed to respond to dapsone therapy and 13-cis-retinoic acid.

  7. CMUT-based volumetric ultrasonic imaging array design for forward looking ICE and IVUS applications

    Science.gov (United States)

    Tekes, Coskun; Zahorian, Jaime; Xu, Toby; Rashid, Muhammad W.; Satir, Sarp; Gurun, Gokce; Karaman, Mustafa; Hasler, Jennifer; Degertekin, F. L.

    2013-03-01

    Designing a mechanically flexible catheter based volumetric ultrasonic imaging device for intravascular and intracardiac imaging is challenging due to small transducer area and limited number of cables. With a few parallel channels, synthetic phased array processing is necessary to acquire data from a large number of transducer elements. This increases the data collection time and hence reduces frame rate and causes artifacts due to tissue-transducer motion. Some of these drawbacks can be resolved by different array designs offered by CMUT-on-CMOS approach. We recently implemented a 2.1-mm diameter single chip 10 MHz dual ring CMUT-on-CMOS array for forward looking ICE with 64-transmit and 56-receive elements along with associated electronics. These volumetric arrays have the small element size required by high operating frequencies and achieve sub mm resolution, but the system would be susceptible to motion artifacts. To enable real time imaging with high SNR, we designed novel arrays consisting of multiple defocused annular rings for transmit aperture and a single ring receive array. The annular transmit rings are utilized to act as a high power element by focusing to a virtual ring shaped line behind the aperture. In this case, image reconstruction is performed by only receive beamforming, reducing total required firing steps from 896 to 14 with a trade-off in image resolution. The SNR of system is improved more than 5 dB for the same frequency and frame rate as compared to the dual ring array, which can be utilized to achieve the same resolution by increasing the operating frequency.

  8. Adiabatic Steam-Water Annular Flow in an Annular Geometry

    DEFF Research Database (Denmark)

    Andersen, P. S.; Würtz, J.

    1981-01-01

    Experimental results for fully developed steam-water annular flow in annular geometries are presented. Rod and tube film flow rates and axial pressure gradients were measured for mass fluxes between 500 and 2000 kg/m2s, steam qualities between 20 and 60 per cent and pressures ranging from 3 to 9 ...

  9. Coalgebraising subsequential transducers

    NARCIS (Netherlands)

    H.H. Hansen (Helle); J. Adamek; C.A. Kupke (Clemens)

    2008-01-01

    htmlabstractSubsequential transducers generalise both classic deterministic automata and Mealy/Moore type state machines by combining (input) language recognition with transduction. In this paper we show that normalisation and taking differentials of subsequential transducers and their underlying

  10. Coalgebraising Subsequential Transducers

    NARCIS (Netherlands)

    Hansen, H.H.

    2008-01-01

    Subsequential transducers generalise both classic deterministic automata and Mealy/Moore type state machines by combining (input) language recognition with transduction. In this paper we show that normalisation and taking differentials of subsequential transducers and their underlying structures can

  11. Driving electrostatic transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis; Knott, Arnold; Andersen, Michael A. E.

    2013-01-01

    Electrostatic transducers represent a very interesting alternative to the traditional inefficient electrodynamic transducers. In order to establish the full potential of these transducers, power amplifiers which fulfill the strict requirements imposed by such loads (high impedance, frequency...... depended, nonlinear and high bias voltage for linearization) must be developed. This paper analyzes power stages and bias configurations suitable for driving an electrostatic transducer. Measurement results of a 300 V prototype amplifier are shown. Measuring THD across a high impedance source is discussed...

  12. Macro tree transducers

    NARCIS (Netherlands)

    Engelfriet, Joost; Vogler, Heiko

    1985-01-01

    Macro tree transducers are a combination of top-down tree transducers and macro grammars. They serve as a model for syntax-directed semantics in which context information can be handled. In this paper the formal model of macro tree transducers is studied by investigating typical automata theoretical

  13. Measurement of Quasi-periodic Oscillating Flow Motion in Simulated Dual-cooled Annular Fuel Bundle

    International Nuclear Information System (INIS)

    Lee, Chi Young; Shin, Chang Hwan; Park, Ju Yong; Oh, Dong Seok; Chun, Tae Hyun; In, Wang Kee

    2012-01-01

    In order to increase a significant amount of reactor power in OPR1000, KAERI (Korea Atomic Energy Research Institute) has been developing a dual-cooled annular fuel. The dual-cooled annular fuel is simultaneously cooled by the water flow through the inner and the outer channels. KAERI proposed the 12x12 dual-cooled annular fuel array which was designed to be structurally compatible with the 16x16 cylindrical solid fuel array by maintaining the same array size and the guide tubes in the same locations, as shown in Fig. 1. In such a case, due to larger outer diameter of dual-cooled annular fuel than conventional solid fuel, a P/D (Pitch-to-Diameter ratio) of dual cooled annular fuel assembly becomes smaller than that of cylindrical solid fuel. A change in P/D of fuel bundle can cause a difference in the flow mixing phenomena between the dual-cooled annular and conventional cylindrical solid fuel assemblies. In this study, the rod bundle flow motion appearing in a small P/D case is investigated preliminarily using PIV (Particle Image Velocimetry) for dual-cooled annular fuel application

  14. Dynamics of Newtonian annular jets

    International Nuclear Information System (INIS)

    Paul, D.D.

    1978-12-01

    The main objectives of this investigation are to identify the significant parameters affecting the dynamics of Newtonian annular jets, and to develop theoretical models for jet break-up and collapse. This study has been motivated by recent developments in laser-fusion reactor designs; one proposed cavity design involves the use of an annular lithium jet to protect the cavity wall from the pellet debris emanating from the microexplosion

  15. Attitude and vibration control of a satellite containing flexible solar arrays by using reaction wheels, and piezoelectric transducers as sensors and actuators

    Science.gov (United States)

    da Fonseca, Ijar M.; Rade, Domingos A.; Goes, Luiz C. S.; de Paula Sales, Thiago

    2017-10-01

    The primary purpose of this paper is to provide insight into control-structure interaction for satellites comprising flexible appendages and internal moving components. The physical model considered herein aiming to attend such purpose is a rigid-flexible satellite consisting of a rigid platform containing two rotating flexible solar panels. The solar panels rotation is assumed to be in a sun-synchronous configuration mode. The panels contain surface-bonded piezoelectric patches that can be used either as sensors for the elastic displacements or as actuators to counteract the vibration motion. It is assumed that in the normal mode operation the satellite platform points towards the Earth while the solar arrays rotate so as to follow the Sun. The vehicle moves in a low Earth polar orbit. The technique used to obtain the mathematical model combines the Lagrangian formulation with the Finite Elements Method used to describe the dynamics of the solar panel. The gravity-gradient torque as well as the torque due to the interaction of the Earth magnetic field and the satellite internal residual magnetic moment is included as environmental perturbations. The actuators are three reaction wheels for attitude control and piezoelectric actuators to control the flexible motion of the solar arrays. Computer simulations are performed using the MATLAB® software package. The following on-orbit satellite operating configurations are object of analysis: i) Satellite pointing towards the Earth (Earth acquisition maneuver) by considering the initial conditions in the elastic displacement equal to zero, aiming the assessment of the flexible modes excitation by the referred maneuver; ii) the satellite pointing towards the Earth with the assumption of an initial condition different from zero for the flexible motion such that the attitude alterations are checked against the elastic motion disturbance; and iii) attitude acquisition accomplished by taking into account initial conditions

  16. An Optimization and Comparative Study of Air-Coupled CMUT Cells With Circular and Annular Geometries.

    Science.gov (United States)

    Na, Shuai; Li, Zhenhao; Wong, Lawrence L P; Chen, Albert I-Hsiang; Macecek, Mirek; Yeow, John T W

    2017-11-01

    Air-coupled capacitive micromachined ultrasonic transducers (CMUTs) with annular cell geometry have recently been reported to have a promising transmit sensitivity. This paper reports three optimization schemes, which further improve the transmit sensitivity and also help achieve a reasonable comparison between the novel annular and conventional circular cells. Lumped element models of both cell types with laminate plate structures are presented. Based on these models, a design optimization flowchart was constructed to facilitate analytical optimization on the three schemes. Circular and annular CMUTs with a common 97-kHz natural resonance frequency were fabricated and characterized to verify the efficacy of the optimization principle. Using the optimization flowchart, annular and circular cells with frequencies ranging from 100 to 300 kHz were analytically optimized and then compared. The comparison results demonstrate that, given the same dc bias and ac excitation voltage, the output power density at the plate surface of the optimized annular cell is double that of the optimized circular cell. Additionally, when generating the same surface power density, an optimized annular cell requires either half the dc bias or half the ac excitation voltage of an optimized circular cell. This paper provides a practical optimization framework for CMUT cell design and demonstrates the superiority of annular cells for air-coupled applications.

  17. Micromachined silicon seismic transducers

    Energy Technology Data Exchange (ETDEWEB)

    Barron, C.C.; Fleming, J.G.; Sniegowski, J.J.; Armour, D.L.; Fleming, R.P.

    1995-08-01

    Batch-fabricated silicon seismic transducers could revolutionize the discipline of CTBT monitoring by providing inexpensive, easily depolyable sensor arrays. Although our goal is to fabricate seismic sensors that provide the same performance level as the current state-of-the-art ``macro`` systems, if necessary one could deploy a larger number of these small sensors at closer proximity to the location being monitored in order to compensate for lower performance. We have chosen a modified pendulum design and are manufacturing prototypes in two different silicon micromachining fabrication technologies. The first set of prototypes, fabricated in our advanced surface- micromachining technology, are currently being packaged for testing in servo circuits -- we anticipate that these devices, which have masses in the 1--10 {mu}g range, will resolve sub-mG signals. Concurrently, we are developing a novel ``mold`` micromachining technology that promises to make proof masses in the 1--10 mg range possible -- our calculations indicate that devices made in this new technology will resolve down to at least sub-{mu}G signals, and may even approach to 10{sup {minus}10} G/{radical}Hz acceleration levels found in the low-earth-noise model.

  18. Volumetric real-time imaging using a CMUT ring array.

    Science.gov (United States)

    Choe, Jung Woo; Oralkan, Ömer; Nikoozadeh, Amin; Gencel, Mustafa; Stephens, Douglas N; O'Donnell, Matthew; Sahn, David J; Khuri-Yakub, Butrus T

    2012-06-01

    A ring array provides a very suitable geometry for forward-looking volumetric intracardiac and intravascular ultrasound imaging. We fabricated an annular 64-element capacitive micromachined ultrasonic transducer (CMUT) array featuring a 10-MHz operating frequency and a 1.27-mm outer radius. A custom software suite was developed to run on a PC-based imaging system for real-time imaging using this device. This paper presents simulated and experimental imaging results for the described CMUT ring array. Three different imaging methods--flash, classic phased array (CPA), and synthetic phased array (SPA)--were used in the study. For SPA imaging, two techniques to improve the image quality--Hadamard coding and aperture weighting--were also applied. The results show that SPA with Hadamard coding and aperture weighting is a good option for ring-array imaging. Compared with CPA, it achieves better image resolution and comparable signal-to-noise ratio at a much faster image acquisition rate. Using this method, a fast frame rate of up to 463 volumes per second is achievable if limited only by the ultrasound time of flight; with the described system we reconstructed three cross-sectional images in real-time at 10 frames per second, which was limited by the computation time in synthetic beamforming.

  19. Contribution to the development and the modelling of an ultrasonic conformable phased array transducer for the contact inspection of 3D complex geometry components; Contribution au developpement et a la modelisation d'un traducteur ultrasonore multielements conformable pour l'inspection au contact de composants a geometrie complexe 3D

    Energy Technology Data Exchange (ETDEWEB)

    Guedes, O

    2005-04-15

    With the difficulties encountered for the exploration of complex shape surfaces, particularly in nuclear industry, the ultrasonic conformable phased array transducer allows a non destructive evaluation of parts with 3D complex parts. For this, one can use the Smart Contact Transducer principle to generate an ultrasonic field by adaptive dynamic focalisation, with a matrix array composed of independent elements moulded in a soft resin. This work deals with the electro-acoustic conception, with the realization of such a prototype and with the study of it's mechanical and acoustic behaviour. The array design is defined using a radiation model adapted to the simulation of contact sources on a free surface. Once one have defined the shape of the radiating elements, a vibratory analysis using finite elements method allows the determination of the emitting structure with 1-3 piezocomposite, witch leads to the realization of emitting-receiving elements. With the measurement of the field transmitted by such elements, we deduced new hypothesis to change the model of radiation. Thus one can take into account normal and tangential stresses calculated with finite element modelling at the interface between the element and the propagation medium, to use it with the semi-analytical model. Some vibratory phenomena dealing with fluid coupling of contact transducers have been studied, and the prediction of the transverse wave radiation profile have been improved. The last part of this work deals with the realization of the first prototype of the conformable phased array transducer. For this a deformation measuring system have been developed, to determine the position of each element on real time with the displacement of the transducer on complex shape surfaces. With those positions, one can perform the calculation of the a delay law intended for the adaptive dynamic focusing of the desired ultrasonic field. The conformable phased array transducer have been characterized in

  20. Handbook of force transducers

    CERN Document Server

    Stefanescu, Dan Mihai

    2011-01-01

    Part I introduces the basic ""Principles and Methods of Force Measurement"" acording to a classification into a dozen of force transducers types: resistive, inductive, capacitive, piezoelectric, electromagnetic, electrodynamic, magnetoelastic, galvanomagnetic (Hall-effect), vibrating wires, (micro)resonators, acoustic and gyroscopic. Two special chapters refer to force balance techniques and to combined methods in force measurement. Part II discusses the ""(Strain Gauge) Force Transducers Components"", evolving from the classical force transducer to the digital / intelligent one, with the inco

  1. Driving electrostatic transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis; Knott, Arnold; Andersen, Michael A. E.

    2013-01-01

    Electrostatic transducers represent a very interesting alternative to the traditional inefficient electrodynamic transducers. In order to establish the full potential of these transducers, power amplifiers which fulfill the strict requirements imposed by such loads (high impedance, frequency...... depended, nonlinear and high bias voltage for linearization) must be developed. This paper analyzes power stages and bias configurations suitable for driving an electrostatic transducer. Measurement results of a 300 V prototype amplifier are shown. Measuring THD across a high impedance source is discussed......, and a high voltage attenuation interface for an audio analyzer is presented. THD below 0:1% is reported....

  2. Active Metamaterial Based Ultrasonic Guided Wave Transducer System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — An active and tunable metamaterial phased array transducer for guided wave mode selection with high intensity per driving channel and with dramatically lower modal...

  3. Programming macro tree transducers

    DEFF Research Database (Denmark)

    Bahr, Patrick; Day, Laurence E.

    2013-01-01

    A tree transducer is a set of mutually recursive functions transforming an input tree into an output tree. Macro tree transducers extend this recursion scheme by allowing each function to be defined in terms of an arbitrary number of accumulation parameters. In this paper, we show how macro tree ...

  4. Subcutaneous granuloma annulare: radiologic appearance

    International Nuclear Information System (INIS)

    Kransdorf, M.J.; Murphey, M.D.; Temple, H.T.

    1998-01-01

    Objective. Granuloma annulare is an uncommon benign inflammatory dermatosis characterized by the formation of dermal papules with a tendency to form rings. There are several clinically distinct forms. The subcutaneous form is the most frequently encountered by radiologists, with the lesion presenting as a superficial mass. There are only a few scattered reports of the imaging appearance of this entity in the literature. We report the radiologic appearance of five cases of subcutaneous granuloma annulare. Design and patients. The radiologic images of five patients (three male, two female) with subcutaneous granuloma annulare were retrospectively studied. Mean patient age was 6.4 years (range, 2-13 years). The lesions occurred in the lower leg (two), foot, forearm, and hand. MR images were available for all lesions, gadolinium-enhanced imaging in three cases, radiographs in four, and bone scintigraphy in one. Results. Radiographs showed unmineralized nodular masses localized to the subcutaneous adipose tissue. The size range, in greatest dimension on imaging studies, was 1-4 cm. MR images show a mass with relatively decreased signal intensity on all pulse sequences, with variable but generally relatively well defined margins. There was extensive diffuse enhancement following gadolinium administration. Conclusion. The radiologic appearance of subcutaneous granuloma annulare is characteristic, typically demonstrating a nodular soft-tissue mass involving the subcutaneous adipose tissue. MR images show a mass with relatively decreased signal intensity on all pulse sequences and variable but generally well defined margins. There is extensive diffuse enhancement following gadolinium administration. Radiographs show a soft-tissue mass or soft-tissue swelling without evidence of bone involvement or mineralization. This radiologic appearance in a young individual is highly suggestive of subcutaneous granuloma annulare. (orig.)

  5. Annular Flow Distribution test. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Kielpinski, A.L. [ed.] [Westinghouse Savannah River Co., Aiken, SC (United States); Childerson, M.T.; Knoll, K.E.; Manolescu, M.I.; Reed, M.J. [Babcock and Wilcox Co., Alliance, OH (United States). Research Center

    1990-12-01

    This report documents the Babcock and Wilcox (B&W) Annular Flow Distribution testing for the Savannah River Laboratory (SRL). The objective of the Annular Flow Distribution Test Program is to characterize the flow distribution between annular coolant channels for the Mark-22 fuel assembly with the bottom fitting insert (BFI) in place. Flow rate measurements for each annular channel were obtained by establishing ``hydraulic similarity`` between an instrumented fuel assembly with the BFI removed and a ``reference`` fuel assembly with the BFI installed. Empirical correlations of annular flow rates were generated for a range of boundary conditions.

  6. Smart transducer with radiomodem

    Science.gov (United States)

    Pugach, V. N.; Voronin, E. L.

    2018-04-01

    Systems for measuring different parameters enabling metering and wireless data transmission are an urgent problem in the industry. One of the most promising solutions is the developments of metering instruments enabling radio-link and GSM data transmission. The article describes a transducer operating with temperature sensors of different types as well as with the sensors of other physical values with the output signal represented as current or voltage with subsequent measurement data transmission from the transducer to the computer via radio-link. The article provides transducer measurement accuracy check. The work confirmed the claimed temperature measurement accuracy, noted a stable data transmission via radio link and convenience of work with the transducer and software.

  7. Pressure Transducer Locations

    Data.gov (United States)

    National Aeronautics and Space Administration — Files are located here, defining the locations of the pressure transducers on the HIRENASD model. These locations also correspond to the locations that analysts...

  8. Annular pulse column development studies

    International Nuclear Information System (INIS)

    Benedict, G.E.

    1980-01-01

    The capacity of critically safe cylindrical pulse columns limits the size of nuclear fuel solvent extraction plants because of the limited cross-sectional area of plutonium, U-235, or U-233 processing columns. Thus, there is a need to increase the cross-sectional area of these columns. This can be accomplished through the use of a column having an annular cross section. The preliminary testing of a pilot-plant-scale annular column has been completed and is reported herein. The column is made from 152.4-mm (6-in.) glass pipe sections with an 89-mm (3.5-in.) o.d. internal tube, giving an annular width of 32-mm (1.25-in.). Louver plates are used to swirl the column contents to prevent channeling of the phases. The data from this testing indicate that this approach can successfully provide larger-cross-section critically safe pulse columns. While the capacity is only 70% of that of a cylindrical column of similar cross section, the efficiency is almost identical to that of a cylindrical column. No evidence was seen of any non-uniform pulsing action from one side of the column to the other

  9. Experimental evaluation of cMUT and PZT transducers in receive only mode for photoacoustic imaging

    Science.gov (United States)

    Warshavski, O.; Meynier, C.; Sénégond, N.; Chatain, P.; Felix, N.; Nguyen-Dinh, A.

    2016-03-01

    In photoacoustic imaging, the angular reception performance of ultrasonic transducers is a critical parameter to be considered for system designers. The quantitative comparison between cMUT and PZT emphasizes the difference between the transducer requirements and specifications between conventional ultrasound and photoacoustic imaging. In this present work, we show significant benefits of cMUT based array transducers over conventional PZT arrays for the improvement of quality in photoacoustic imaging systems.

  10. Volumetric Flow Measurement Using an Implantable CMUT Array.

    Science.gov (United States)

    Mengli Wang; Jingkuang Chen

    2011-06-01

    This paper describes volumetric-flow velocity measurement using an implantable capacitive micromachined ultrasonic transducer (CMUT) array. The array is comprised of multiple-concentric CMUT rings for ultrasound transmission and an outmost annular CMUT array for ultrasound reception. Microelectromechanical-system (MEMS) fabrication technology allows reception CMUT on this flowmeter to be implemented with a different membrane thickness and gap height than that of transmission CMUTs, optimizing the performance of these two different kinds of devices. The silicon substrate of this 2-mm-diameter CMUT ring array was bulk micromachined to approximately 80 to 100 μm thick, minimizing tissue disruption. The blood-flow velocity was detected using pulse ultrasound Doppler by comparing the demodulated echo ultrasound with the incident ultrasound. The demodulated ultrasound signal was sampled by a pulse delayed in time domain from the transmitted burst, which corresponds to detecting the signal at a specific distance. The flow tube/vessel diameter was detected through the time-flight delay difference from near and far wall reflections, which was measured from the ultrasound pulse echo. The angle between the ultrasound beam and the flow was found by using the cross-correlation from consecutive ultrasound echoes. Artificial blood flowing through three different polymer tubes was experimented with, while keeping the same volumetric flow rate. The discrepancy in flow measurement results between this CMUT meter and a calibrated laser Doppler flowmeter is less than 5%.

  11. Rapid prototyping fabrication of focused ultrasound transducers.

    Science.gov (United States)

    Kim, Yohan; Maxwell, Adam D; Hall, Timothy L; Xu, Zhen; Lin, Kuang-Wei; Cain, Charles A

    2014-09-01

    Rapid prototyping (RP) fabrication techniques are currently widely used in diverse industrial and medical fields, providing substantial advantages in development time and costs in comparison to more traditional manufacturing processes. This paper presents a new method for the fabrication of high-intensity focused ultrasound transducers using RP technology. The construction of a large-aperture hemispherical transducer designed by computer software is described to demonstrate the process. The transducer was conceived as a modular design consisting of 32 individually focused 50.8-mm (2-in) PZT-8 element modules distributed in a 300-mm hemispherical scaffold with a geometric focus of 150 mm. The entire structure of the array, including the module housings and the hemispherical scaffold was fabricated through a stereolithography (SLA) system using a proprietary photopolymer. The PZT elements were bonded to the lenses through a quarter-wave tungsten-epoxy matching layer developed in-house specifically for this purpose. Modules constructed in this manner displayed a high degree of electroacoustic consistency, with an electrical impedance mean and standard deviation of 109 ± 10.2 Ω for the 32 elements. Time-of-flight measurements for individually pulsed modules mounted on the hemispherical scaffold showed that all pulses arrived at the focus within a 350 ns range, indicating a good degree of element alignment. Pressure profile measurements of the fully assembled transducer also showed close agreement with simulated results. The measured focal beam FWHM dimensions were 1.9 × 4.0 mm (1.9 × 3.9 mm simulated) in the transversal and axial directions respectively. Total material expenses associated with the construction of the transducer were approximately 5000 USD (as of 2011). The versatility and lower fabrication costs afforded by RP methods may be beneficial in the development of complex transducer geometries suitable for a variety of research and clinical applications.

  12. Vibration transducer calibration techniques

    Science.gov (United States)

    Brinkley, D. J.

    1980-09-01

    Techniques for the calibration of vibration transducers used in the Aeronautical Quality Assurance Directorate of the British Ministry of Defence are presented. Following a review of the types of measurements necessary in the calibration of vibration transducers, the performance requirements of vibration transducers, which can be used to measure acceleration, velocity or vibration amplitude, are discussed, with particular attention given to the piezoelectric accelerometer. Techniques for the accurate measurement of sinusoidal vibration amplitude in reference-grade transducers are then considered, including the use of a position sensitive photocell and the use of a Michelson laser interferometer. Means of comparing the output of working-grade accelerometers with that of previously calibrated reference-grade devices are then outlined, with attention given to a method employing a capacitance bridge technique and a method to be used at temperatures between -50 and 200 C. Automatic calibration procedures developed to speed up the calibration process are outlined, and future possible extensions of system software are indicated.

  13. Transduced space and transvisuality

    DEFF Research Database (Denmark)

    Michelsen, Anders Ib

    2017-01-01

    feeds into the matter of architecture in new ways. On this background, the chapter discusses the ideas behind the drawing material of Architecture, Time and Form as presented in this book, as a relationship between transduced space and transvisual aesthetics. The material of drawing treated in this book...

  14. Magnetoelastic Generator Type Transducer

    Directory of Open Access Journals (Sweden)

    A. K. Efremov

    2014-01-01

    Full Text Available Some issues relating to usage of magnetoelectric generator type transducers as the means of measuring intense dynamic loads and as a sensitive element of fuse contact target sensor (CTS are considered. Particular attention is paid to the magnetoanisotropic transducer (MAT, the principle of operation of which is based on the change of the magnetic field form caused by the applied mechanical load leading to the appearance of EMF in the output winding. The MAT, especially monolithic, has such advantages as high strength, reliability, endurance and design simplicity.The functional transducer schemes have been analyzed and for the first time it was shown that there is a possibility of using a version with only one output winding arranged in the magnetic conductor made of magnetically soft material such as structural steel. A mathematical model of transducer is proposed showing that the input signal formed by the external load is proportional to its derivative. With a sufficiently large time constant of the electric circuit and the implementation of a number of additional conditions the transducer may function as an integrator. By that it becomes possible to measure the parameters of dynamic processes having the duration of a few to tens of microseconds. Unlike the traditional transducers such as piezoelectric the output signal is not “masked” by the natural oscillations.The mechanism of the generator effect was considered leading to the “piezomagnetodynamic” model, which includes a number of phenomenological parameters. Some corresponding experimentally derived hysteresis curves are presented. Their vertical shift quantifies the generator effect and does not depend on the intensity of the magnetic field.As an example of practical application of the MAT some results of evaluation of the dynamic force characteristic of the heading part of a piezoelectric fuse are presented. The MAT was also used for the evaluation of back effects of the bullet

  15. Soliton bunching in annular Josephson junctions

    DEFF Research Database (Denmark)

    Vernik, I.V; Lazarides, Nickos; Sørensen, Mads Peter

    1996-01-01

    By studying soliton (fluxon) motion in long annular Josephson junctions it is possible to avoid the influence of the boundaries and soliton-soliton collisions present in linear junctions. A new experimental design consisting of a niobium coil placed on top of an annular junction has been used...

  16. Nano-optomechanical transducer

    Science.gov (United States)

    Rakich, Peter T; El-Kady, Ihab F; Olsson, Roy H; Su, Mehmet Fatih; Reinke, Charles; Camacho, Ryan; Wang, Zheng; Davids, Paul

    2013-12-03

    A nano-optomechanical transducer provides ultrabroadband coherent optomechanical transduction based on Mach-wave emission that uses enhanced photon-phonon coupling efficiencies by low impedance effective phononic medium, both electrostriction and radiation pressure to boost and tailor optomechanical forces, and highly dispersive electromagnetic modes that amplify both electrostriction and radiation pressure. The optomechanical transducer provides a large operating bandwidth and high efficiency while simultaneously having a small size and minimal power consumption, enabling a host of transformative phonon and signal processing capabilities. These capabilities include optomechanical transduction via pulsed phonon emission and up-conversion, broadband stimulated phonon emission and amplification, picosecond pulsed phonon lasers, broadband phononic modulators, and ultrahigh bandwidth true time delay and signal processing technologies.

  17. Numerical transducer modelling

    DEFF Research Database (Denmark)

    Cutanda, Vicente

    1999-01-01

    Numerical modelling is of importance for the design, improvement and study of acoustic transducers such as microphones and accelerometers. Techniques like the boundary element method and the finite element method are the most common supplement to the traditional empirical and analytical approaches...... errors and instabilities in the computations of numerical solutions. An investigation to deal with this narrow-gap problem has been carried out....

  18. Steerable Doppler transducer probes

    International Nuclear Information System (INIS)

    Fidel, H.F.; Greenwood, D.L.

    1986-01-01

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis

  19. Biasing of Capacitive Micromachined Ultrasonic Transducers.

    Science.gov (United States)

    Caliano, Giosue; Matrone, Giulia; Savoia, Alessandro Stuart

    2017-02-01

    Capacitive micromachined ultrasonic transducers (CMUTs) represent an effective alternative to piezoelectric transducers for medical ultrasound imaging applications. They are microelectromechanical devices fabricated using silicon micromachining techniques, developed in the last two decades in many laboratories. The interest for this novel transducer technology relies on its full compatibility with standard integrated circuit technology that makes it possible to integrate on the same chip the transducers and the electronics, thus enabling the realization of extremely low-cost and high-performance devices, including both 1-D or 2-D arrays. Being capacitive transducers, CMUTs require a high bias voltage to be properly operated in pulse-echo imaging applications. The typical bias supply residual ripple of high-quality high-voltage (HV) generators is in the millivolt range, which is comparable with the amplitude of the received echo signals, and it is particularly difficult to minimize. The aim of this paper is to analyze the classical CMUT biasing circuits, highlighting the features of each one, and to propose two novel HV generator architectures optimized for CMUT biasing applications. The first circuit proposed is an ultralow-residual ripple (CMUT by charging a buffer capacitor synchronously with the pulsing sequence, thus reducing the impact of the switching noise on the received echo signals. The small area of the circuit (about 1.5 cm 2 ) makes it possible to generate the bias voltage inside the probe, very close to the CMUT, making the proposed solution attractive for portable applications. Measurements and experiments are shown to demonstrate the effectiveness of the new approaches presented.

  20. Design and fabrication of liner-arroy ultrasonic transducer using KLM and FEM simulation for non-destructive testing

    International Nuclear Information System (INIS)

    Park, Chan Yuk; Sung, Jin Ho; Jeong, Jong Seob

    2015-01-01

    In this paper, a linear-array transducer capable of overcoming the faults of a single element and phased array transducers with convex shape for non-destructive ultrasonic testing was designed and fabricated. A 5.5 MHz linear-array transducer was designed using the PiezoCAD program based on the KLM analysis and the PZFlex program based on the FEM analysis. A 2-2 composite structure was employed to achieve broad-band characteristics. A 128 element linear-array transducer was fabricated and its performance was compared with the simulation results. The center frequency of the fabricated transducer was 5.5 Mhzand the -6 dB frequency bandwidth was 70 %. Thus, we expect that the designed transducer can provide an effective inner image of the test material during non-destructive ultrasonic testing.

  1. Piezoelectric hollow sphere transducers: The 'BBs'

    Science.gov (United States)

    Alkoy, Sedat

    spheres. Underwater sonar performance was evaluated by measuring free field voltage sensitivity (FFVS), transmit voltage response (TVR), source level and directivity beam patterns of these hydrophones. FFVS of -218 dB re 1V/μPa with a frequency independent response up to 500 kHz, and TVR of 150 dB @1m re 1μPa/V at 500 kHz were obtained from these transducers. These results were compared to that of the finite element analysis of these devices. Hollow spheres were also placed into multi-element arrays with elements electrically connected to one another in parallel, series or a mix of both. Higher TVR, FFVS and directional beam patterns were obtained from these arrays.

  2. Divergent Field Annular Ion Engine Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed work investigates an approach that would allow an annular ion engine geometry to achieve ion beam currents approaching the Child-Langmuir limit. In this...

  3. Divergent Field Annular Ion Engine, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed work investigates an approach that would allow an annular ion engine geometry to achieve ion beam currents approaching the Child-Langmuir limit. In this...

  4. Annular Hybrid Rocket Motor, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Engineers at SpaceDev have conducted a preliminary design and analysis of a proprietary annular design concept for a hybrid motor. A U.S. Patent application has been...

  5. Adaptive optics scanning ophthalmoscopy with annular pupils

    Science.gov (United States)

    Sulai, Yusufu N.; Dubra, Alfredo

    2012-01-01

    Annular apodization of the illumination and/or imaging pupils of an adaptive optics scanning light ophthalmoscope (AOSLO) for improving transverse resolution was evaluated using three different normalized inner radii (0.26, 0.39 and 0.52). In vivo imaging of the human photoreceptor mosaic at 0.5 and 10° from fixation indicates that the use of an annular illumination pupil and a circular imaging pupil provides the most benefit of all configurations when using a one Airy disk diameter pinhole, in agreement with the paraxial confocal microscopy theory. Annular illumination pupils with 0.26 and 0.39 normalized inner radii performed best in terms of the narrowing of the autocorrelation central lobe (between 7 and 12%), and the increase in manual and automated photoreceptor counts (8 to 20% more cones and 11 to 29% more rods). It was observed that the use of annular pupils with large inner radii can result in multi-modal cone photoreceptor intensity profiles. The effect of the annular masks on the average photoreceptor intensity is consistent with the Stiles-Crawford effect (SCE). This indicates that combinations of images of the same photoreceptors with different apodization configurations and/or annular masks can be used to distinguish cones from rods, even when the former have complex multi-modal intensity profiles. In addition to narrowing the point spread function transversally, the use of annular apodizing masks also elongates it axially, a fact that can be used for extending the depth of focus of techniques such as adaptive optics optical coherence tomography (AOOCT). Finally, the positive results from this work suggest that annular pupil apodization could be used in refractive or catadioptric adaptive optics ophthalmoscopes to mitigate undesired back-reflections. PMID:22808435

  6. Fabrication of Sintered Annular Fuel Pellet

    International Nuclear Information System (INIS)

    Rhee, Young Woo; Kim, Dong Joo; Kim, Jong Hun; Yang, Jae Ho; Kim, Keon Sik; Kang, Ki Won; Song, Kun Woo

    2010-01-01

    A dual cooled annular fuel has been seriously considered as a favorable option for uprating the power density of a Pressurized Water Reactor fuel assembly. An annular fuel has a geometrically inherent advantage such as an increased heat transfer area and a thin pellet thickness. It results in a lot of advantages from the point of a fuel safety and its economy. In order to actualize the dual cooled fuel, an essential element is the annular pellet with precisely controlled diametric tolerance. However, the unique shape of annular fuel pellet causes challenging difficulties to satisfy a diametric tolerance specification. Because of an inhomogeneous green density distribution along the compact height, an hour-glassing usually occurred in a sintered cylindrical PWR fuel pellet fabricated by a conventional doubleacting press. Thus, a sintered pellet usually undergoes a centerless grinding process in order to secure a pellet's specifications. In the case of an annular pellet fabrication using a conventional double-acting press, the same hour-glass shape would probably occur. The outer diameter tolerance of an annular pellet can be controlled easily similar to that of a conventional cylindrical PWR pellet through a centerless grinding. However, it appears not to be simple in the case of an inner surface grinding. It would be the best way to satisfy the specifications for the inner diameter in an as-fabricated pellet. In the present study, we are trying to find a way to minimize the diametric tolerance of the sintered annular pellet without inner surface grinding. This paper deals with a new approach that we have tried to reduce the diametric tolerance of the sintered annular pellet

  7. All optical detection of picosecond spin-wave dynamics in 2D annular antidot lattice

    Science.gov (United States)

    Porwal, Nikita; Mondal, Sucheta; Choudhury, Samiran; De, Anulekha; Sinha, Jaivardhan; Barman, Anjan; Datta, Prasanta Kumar

    2018-02-01

    Novel magnetic structures with precisely controlled dimensions and shapes at the nanoscale have potential applications in spin logic, spintronics and other spin-based communication devices. We report the fabrication of 2D bi-structure magnonic crystal in the form of embedded nanodots in a periodic Ni80Fe20 antidot lattice structure (annular antidot) by focused ion-beam lithography. The spin-wave spectra of the annular antidot sample, studied for the first time by a time-resolved magneto-optic Kerr effect microscopy show a remarkable variation with bias field, which is important for the above device applications. The optically induced spin-wave spectra show multiple modes in the frequency range 14.7 GHz-3.5 GHz due to collective interactions between the dots and antidots as well as the annular elements within the whole array. Numerical simulations qualitatively reproduce the experimental results, and simulated mode profiles reveal the spatial distribution of the spin-wave modes and internal magnetic fields responsible for these observations. It is observed that the internal field strength increases by about 200 Oe inside each dot embedded within the hole of annular antidot lattice as compared to pure antidot lattice and pure dot lattice. The stray field for the annular antidot lattice is found to be significant (0.8 kOe) as opposed to the negligible values of the same for the pure dot lattice and pure antidot lattice. Our findings open up new possibilities for development of novel artificial crystals.

  8. Development of annular coupled structure

    International Nuclear Information System (INIS)

    Kageyama, T.; Morozumi, Y.; Yoshino, K.; Yamazaki, Y.

    1992-01-01

    A π/2-mode standing-wave linac of an Annular Coupled Structure (ACS) has been developed for the 1-GeV proton linac of the Japanese Hadron Project (JHP). This ACS has four coupling slots between accelerating and coupling cells in order to overcome difficulties in putting the ACS to practical use. Two prototypes of a four-slot ACS (f = 1296 MHz, β = v/c = 0.8) have been constructed and tested: one with a staggered slot-orientation from cell to cell; and the other with a uniform one. The staggered configuration gives a larger coupling constant and a larger shunt impedance than the uniform one with the same size of coupling slot. Both models have been conditioned up to the design input RF power. The four-slot ACS gives a distortion-free accelerating field around the beam axis, while a Side-Coupled Structure cavity gives an accelerating field mixed with a TE111-like mode. (Author) 7 figs., 2 tabs., 9 refs

  9. Simulating Capacitive Micromachined Ultrasonic Transducers (CMUTs) using Field II

    DEFF Research Database (Denmark)

    Bæk, David; Oralkan, Omer; Kupnik, Mario

    2010-01-01

    which it calculates the SIR responses. The program features predefined models for classical transducer geometries, but currently none for the fast advancing CMUTs. This work addresses the assumptions required for modeling CMUTs with Field II. It is shown that rectangular array elements, populated...

  10. Characterization of a novel Optical Micro-machined Ultrasound Transducer

    NARCIS (Netherlands)

    Leinders, S.M.

    2017-01-01

    We design and demonstrate a prototype ultrasound sensor based on a photonic micro-ring resonator integrated on a silicon membrane, and show that it can detect very low pressure ultrasound waves. The use of integrated photonics in future array transducers has several benefits: for instance it

  11. Ultrasonic Transducers for Fourier Analysis.

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    1995-01-01

    Describes an experiment that uses the ultrasonic transducer for demonstrating the Fourier components of waveshapes such as the square and triangular waves produced by laboratory function generators. (JRH)

  12. Optically transduced MEMS magnetometer

    Science.gov (United States)

    Nielson, Gregory N; Langlois, Eric

    2014-03-18

    MEMS magnetometers with optically transduced resonator displacement are described herein. Improved sensitivity, crosstalk reduction, and extended dynamic range may be achieved with devices including a deflectable resonator suspended from the support, a first grating extending from the support and disposed over the resonator, a pair of drive electrodes to drive an alternating current through the resonator, and a second grating in the resonator overlapping the first grating to form a multi-layer grating having apertures that vary dimensionally in response to deflection occurring as the resonator mechanically resonates in a plane parallel to the first grating in the presence of a magnetic field as a function of the Lorentz force resulting from the alternating current. A plurality of such multi-layer gratings may be disposed across a length of the resonator to provide greater dynamic range and/or accommodate fabrication tolerances.

  13. Numerical Transducer Modeling

    DEFF Research Database (Denmark)

    Henriquez, Vicente Cutanda

    This thesis describes the development of a numerical model of the propagation of sound waves in fluids with viscous and thermal losses, with application to the simulation of acoustic transducers, in particular condenser microphones for measurement. The theoretical basis is presented, numerical...... tools and implementation techniques are described and performance tests are carried out. The equations that govern the motion of fluids with losses and the corresponding boundary conditions are reduced to a form that is tractable for the Boundary Element Method (BEM) by adopting some hypotheses...... that are allowable in this case: linear variations, absence of flow, harmonic time variation, thermodynamical equilibrium and physical dimensions much larger than the molecular mean free path. A formulation of the BEM is also developed with an improvement designed to cope with the numerical difficulty associated...

  14. Calibration of Underwater Sound Transducers

    OpenAIRE

    H.R.S. Sastry

    1983-01-01

    The techniques of calibration of underwater sound transducers for farfield, near-field and closed environment conditions are reviewed in this paper .The design of acoustic calibration tank is mentioned. The facilities available at Naval Physical & Oceanographic Laboratory, Cochin for calibration of transducers are also listed.

  15. Receive-Noise Analysis of Capacitive Micromachined Ultrasonic Transducers.

    Science.gov (United States)

    Bozkurt, Ayhan; Yaralioglu, G Goksenin

    2016-11-01

    This paper presents an analysis of thermal (Johnson) noise received from the radiation medium by otherwise noiseless capacitive micromachined ultrasonic transducer (CMUT) membranes operating in their fundamental resonance mode. Determination of thermal noise received by multiple numbers of transducers or a transducer array requires the assessment of cross-coupling through the radiation medium, as well as the self-radiation impedance of the individual transducer. We show that the total thermal noise received by the cells of a CMUT has insignificant correlation, and is independent of the radiation impedance, but is only determined by the mass of each membrane and the electromechanical transformer ratio. The proof is based on the analytical derivations for a simple transducer with two cells, and extended to transducers with numerous cells using circuit simulators. We used a first-order model, which incorporates the fundamental resonance of the CMUT. Noise power is calculated by integrating over the entire spectrum; hence, the presented figures are an upper bound for the noise. The presented analyses are valid for a transimpedance amplifier in the receive path. We use the analysis results to calculate the minimum detectable pressure of a CMUT. We also provide an analysis based on the experimental data to show that output noise power is limited by and comparable to the theoretical upper limit.

  16. Damage detection in concrete structures with smart piezoceramic transducers

    Science.gov (United States)

    Naidu, Akshay S. K.; Bhalla, Suresh

    2003-10-01

    Detection of damages and progressive deterioration in structures is a critical issue. Visual inspections are tedious and unreliable. Incipient damages are often not discernible by low frequency dynamic response and other NDE techniques. Smart piezoelectric ceramic (PZT) transducers are emerging as an effective alternative in health monitoring of structures. The electro-mechanical impedance method employs the self-actuating and sensing characteristics of the PZT, without having to use actuators and sensors separately. When excited by an ac source, the PZT transducers bonded to the host structure activates the higher modes of vibration locally. Changes in the admittance response of the transducer serves as an indicator of damage around the transducer. In this paper, the effectiveness of PZT transducers for characterizing damages in concrete, in terms of the damage extent and location, is experimentally examined. The root mean square deviation (RMSD) index, adopted to quantify the changes in the admittance signatures, correlates with the damage extent. The damages on the surface that is not mounted by the PZT are also discernible. An array of transducers proves effective in detecting the damaged zone. The progressive incipient crack can be detected much before it actually becomes visible to the naked eye.

  17. Annular feed air breathing fuel cell stack

    Science.gov (United States)

    Wilson, Mahlon S.

    1996-01-01

    A stack of polymer electrolyte fuel cells is formed from a plurality of unit cells where each unit cell includes fuel cell components defining a periphery and distributed along a common axis, where the fuel cell components include a polymer electrolyte membrane, an anode and a cathode contacting opposite sides of the membrane, and fuel and oxygen flow fields contacting the anode and the cathode, respectively, wherein the components define an annular region therethrough along the axis. A fuel distribution manifold within the annular region is connected to deliver fuel to the fuel flow field in each of the unit cells. In a particular embodiment, a single bolt through the annular region clamps the unit cells together. In another embodiment, separator plates between individual unit cells have an extended radial dimension to function as cooling fins for maintaining the operating temperature of the fuel cell stack.

  18. What causes Mars' annular polar vortices?

    Science.gov (United States)

    Toigo, A. D.; Waugh, D. W.; Guzewich, S. D.

    2017-01-01

    A distinctive feature of the Martian atmosphere is that the winter polar vortices exhibit annuli of high potential vorticity (PV) with a local minimum near the pole. These annuli are seen in observations, reanalyses, and free-running general circulation model simulations of Mars, but are not generally a feature of Earth's polar vortices, where there is a monotonic increase in magnitude of PV with latitude. The creation and maintenance of the annular polar vortices on Mars are not well understood. Here we use simulations with a Martian general circulation model to the show that annular vortices are related to another distinctive, and possibly unique in the solar system, feature of the Martian atmosphere: the condensation of the predominant atmospheric gas species (CO2) in polar winter regions. The latent heat associated with CO2 condensation leads to destruction of PV in the polar lower atmosphere, inducing the formation of an annular PV structure.

  19. Aceclofenac-induced erythema annulare centrifugum

    Directory of Open Access Journals (Sweden)

    Dilip Meena

    2018-01-01

    Full Text Available Erythema annulare centrifugum (EAC is characterised by slowly enlarging annular erythematous lesions and is thought to represent a clinical reaction pattern to infections, medications, and rarely, underlying malignancy. Causative drugs include chloroquine, cimetidine, gold sodium thiomalate, amitriptyline, finasteride, etizolam etc. We present a case of 40-year-old woman who presented to us with a 10 days history of nonpruritic, peripherally growing annular erythematous eruption. She had a history of recent onset of joint pain, for which she was taking aceclofenac 90 mg once a day for 5 days prior to the onset of the rash. This was confirmed on biopsy as EAC. The rash promptly subsided after stopping the drug. We report this case as there was no previous report of aceclofenac induced EAC.

  20. Capacitive Micromachined Ultrasonic Transducers for Therapeutic Ultrasound Applications

    Science.gov (United States)

    Wong, Serena H.; Kupnik, Mario; Watkins, Ronald D.; Butts-Pauly, Kim; Khuri-Yakub, Butrus T.

    2014-01-01

    Therapeutic ultrasound guided by magnetic resonance imaging (MRI) is a noninvasive treatment that potentially reduces mortality, lowers medical costs, and widens accessibility of treatments for patients. Recent developments in the design and fabrication of capacitive micromachined ultrasonic transducers (CMUTs) have made them competitive with piezoelectric transducers for use in therapeutic ultrasound applications. In this paper, we present the first designs and prototypes of an 8-element, concentric-ring, CMUT array to treat upper abdominal cancers. This array was simulated and designed to focus 30–50 mm into tissue and ablate a 2–3 cm diameter tumor within 1 hour. Assuming a surface acoustic output pressure of 1 MPa peak to peak (8.5 W/cm2) at 2.5 MHz, we simulated an array that produced a focal intensity of 680 W/cm2 when focusing to 35 mm. CMUT cells were then designed to meet these frequency and surface acoustic intensity specifications. These cell designs were fabricated as 2.5 mm by 2.5 mm test transducers and used to verify our models. The test transducers were shown to operate at 2.5 MHz with an output pressure of 1.4 MPa peak to peak (16.3 W/cm2). With this CMUT cell design, we fabricated a full 8-element array. Due to yield issues, we only developed electronics to focus the four center elements of the array. The beam profile of the measured array deviated from the simulated because of crosstalk effects; the beamwidth matched within 10% and sidelobes increased by 2 times, which caused the measured gain to be 16.6 compared to 27.4. PMID:19628448

  1. Subaperture stitching tolerancing for annular ring geometry.

    Science.gov (United States)

    Smith, Greg A; Burge, James H

    2015-09-20

    Subaperture stitching is an economical way to extend small-region, high-resolution interferometric metrology to cover large-aperture optics. Starting from system geometry and measurement noise knowledge, this work derives an analytical expression for how noise in an annular ring of subapertures leads to large-scale errors in the computed stitched surface. These errors scale as sin(πp/M)(-2) where p is the number of sine periods around the annular full-aperture and M is the number of subaperture measurements. Understanding how low-spatial-frequency surface errors arise from subaperture noise is necessary for tolerancing systems which use subaperture stitching.

  2. Micromachined Integrated Transducers for Ultrasound Imaging

    DEFF Research Database (Denmark)

    la Cour, Mette Funding

    The purpose of this project is to develop capacitive micromachined ultrasonic transducers (CMUTs) for medical imaging. Medical ultrasound transducers used today are fabricated using piezoelectric materials and bulk processing. To fabricate transducers capable of delivering a higher imaging...

  3. Optimal Thrust Vectoring for an Annular Aerospike Nozzle, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Recent success of an annular aerospike flight test by NASA Dryden has prompted keen interest in providing thrust vector capability to the annular aerospike nozzle...

  4. Optimal Thrust Vectoring for an Annular Aerospike Nozzle Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Recent success of an annular aerospike flight test by NASA Dryden has prompted keen interest in providing thrust vector capability to the annular aerospike nozzle...

  5. Optimal Thrust Vectoring for an Annular Aerospike Nozzle, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Recent success of an annular aerospike flight test by NASA Dryden has prompted keen interest in providing thrust vector capability to the annular aerospike nozzle...

  6. Effect of annular secondary conductor in a linear electromagnetic ...

    Indian Academy of Sciences (India)

    This paper presents the variation of average axial force density in the annular secondary conductor of a linear electromagnetic stirrer. Different geometries of secondaries are considered for numerical and experimental validation namely, 1. hollow annular ring, 2. annular ring with a solid cylinder and 3. solid cylinder.

  7. Annular Pressure Seals and Hydrostatic Bearings

    National Research Council Canada - National Science Library

    San Andres, Luis

    2006-01-01

    ..., in particular those handling large density fluids. Highlights on the bulk-flow analysis of annular seals are given with details on the performance of two water seals long and short, featuring the advantages of an anti-swirl brake to enhance the seal...

  8. Annular beam with segmented phase gradients

    Directory of Open Access Journals (Sweden)

    Shubo Cheng

    2016-08-01

    Full Text Available An annular beam with a single uniform-intensity ring and multiple segments of phase gradients is proposed in this paper. Different from the conventional superposed vortices, such as the modulated optical vortices and the collinear superposition of multiple orbital angular momentum modes, the designed annular beam has a doughnut intensity distribution whose radius is independent of the phase distribution of the beam in the imaging plane. The phase distribution along the circumference of the doughnut beam can be segmented with different phase gradients. Similar to a vortex beam, the annular beam can also exert torques and rotate a trapped particle owing to the orbital angular momentum of the beam. As the beam possesses different phase gradients, the rotation velocity of the trapped particle can be varied along the circumference. The simulation and experimental results show that an annular beam with three segments of different phase gradients can rotate particles with controlled velocities. The beam has potential applications in optical trapping and optical information processing.

  9. Common pass decentered annular ring resonator

    Energy Technology Data Exchange (ETDEWEB)

    Holmes, D. A.; Waite, T. R.

    1985-04-30

    An optical resonator having an annular cylindrical gain region for use in a chemical laser or the like in which two ring-shaped mirrors having substantially conical reflecting surfaces are spaced apart along a common axis of revolution of the respective conical surfaces. A central conical mirror reflects incident light directed along said axis radially outwardly to the reflecting surface of a first one of the ring-shaped mirrors. The radial light rays are reflected by the first ring mirror to the second ring mirror within an annular cylindrical volume concentric with said common axis and forming a gain region. Light rays impinging on the second ring mirror are reflected to diametrically opposite points on the same conical mirror surfaces and back to the first ring mirror through the same annular cylindrical volume. The return rays are then reflected by the conical mirror surface of the first ring mirror back to the central conical mirror. The mirror surfaces are angled such that the return rays are reflected back along the common axis by the central mirror in a concentric annular cylindrical volume. A scraper mirror having a central opening centered on said axis and an offset opening reflects all but the rays passing through the two openings in an output beam. The rays passing through the second opening are reflected back through the first opening to provide feedback.

  10. Direct numerical simulation of supercritical annular electroconvection

    NARCIS (Netherlands)

    Tsai, Peichun Amy; Daya, Zahir A.; Deyirmenjian, Vatche B.; Morris, Stephen W.

    2007-01-01

    We use direct numerical simulation to study electrically driven convection in an annular thin film. The simulation models a laboratory experiment that consists of a weakly conducting, submicron thick liquid crystal film suspended between two concentric electrodes. The film is driven to convect by

  11. Granuloma annulare displaying pseudorosettes in Borelia infection.

    Science.gov (United States)

    Fernandez-Flores, A; Ruzic-Sabljic, E

    2008-12-01

    In 2003, pseudorosettes were described as highly suspicious of infection by Borrelia burgdorferi sensu lato in the appropriate clinical context. Nevertheless, such a pattern has been described in the literature in other non-infectious conditions. On the other hand, granuloma annulare (GA) has been recently closely associated with infection by Borrelia. We investigated how frequently pseudorosettes can be detected in common GA cases confirmed for Borrelia by PCR. We studied 13 biopsies of non-interstitial GA and 2 biopsies of interstitial GA from patients without clinical suspicion of borrelial infection. We also performed immunohistochemical studies in all the biopsies, using the CD-68 antibody. Molecular studies with PCR were performed with beta-globin PCR (human DNA). Borrelial DNA was confirmed by amplifying the OspA gene and intergenic rrf-rrl region. We found histiocytic pseudorosettes in 13 biopsies (86.66%). Human DNA was successfully amplified from 8 of 13 paraffin-embedded skin samples. From these we amplified borrelial DNA in 5 of 8 samples. Out of the 8 cases in which human DNA was amplified, a correlation between pseudorosettes and the molecular tests (Borrelia DNA) was confirmed in 5 instances. a) Pseudorosettes are not an unusual finding in common granuloma annulare; b) Borrelia is present in (most) cases of granuloma annulare; and c) Pseudorosettes seem to be a good morphological sign predictive of infection with Borrelia in granuloma annulare.

  12. Experimental critical parameters of enriched uranium solution in annular tank geometries

    Energy Technology Data Exchange (ETDEWEB)

    Rothe, R.E.

    1996-04-01

    A total of 61 critical configurations are reported for experiments involving various combinations of annular tanks into which enriched uranium solution was pumped. These experiments were performed at two widely separated times in the 1980s under two programs at the Rocky Flats Plant`s Critical Mass Laboratory. The uranyl nitrate solution contained about 370 g of uranium per liter, but this concentration varied a little over the duration of the studies. The uranium was enriched to about 93% [sup 235]U. All tanks were typical of sizes commonly found in nuclear production plants. They were about 2 m tall and ranged in diameter from 0.6 m to 1.5 m. Annular thicknesses and conditions of neutron reflection, moderation, and absorption were such that criticality would be achieved with these dimensions. Only 13 of the entire set of 74 experiments proved to be subcritical when tanks were completely filled with solution. Single tanks of several radial thicknesses were studied as well as small line arrays (1 x 2 and 1 x 3) of annular tanks. Many systems were reflected on four sides and the bottom by concrete, but none were reflected from above. Many experiments also contained materials within and outside the annular regions that contained strong neutron absorbers. One program had such a thick external moderator/absorber combination that no reflector was used at all.

  13. Experimental critical parameters of enriched uranium solution in annular tank geometries

    International Nuclear Information System (INIS)

    Rothe, R.E.

    1996-04-01

    A total of 61 critical configurations are reported for experiments involving various combinations of annular tanks into which enriched uranium solution was pumped. These experiments were performed at two widely separated times in the 1980s under two programs at the Rocky Flats Plant's Critical Mass Laboratory. The uranyl nitrate solution contained about 370 g of uranium per liter, but this concentration varied a little over the duration of the studies. The uranium was enriched to about 93% [sup 235]U. All tanks were typical of sizes commonly found in nuclear production plants. They were about 2 m tall and ranged in diameter from 0.6 m to 1.5 m. Annular thicknesses and conditions of neutron reflection, moderation, and absorption were such that criticality would be achieved with these dimensions. Only 13 of the entire set of 74 experiments proved to be subcritical when tanks were completely filled with solution. Single tanks of several radial thicknesses were studied as well as small line arrays (1 x 2 and 1 x 3) of annular tanks. Many systems were reflected on four sides and the bottom by concrete, but none were reflected from above. Many experiments also contained materials within and outside the annular regions that contained strong neutron absorbers. One program had such a thick external moderator/absorber combination that no reflector was used at all

  14. Transducer Field Imaging Using Acoustography

    Directory of Open Access Journals (Sweden)

    Jaswinder S. Sandhu

    2012-01-01

    Full Text Available A common current practice for transducer field mapping is to scan, point-by-point, a hydrophone element in a 2D raster at various distances from the transducer radiating surface. This approach is tedious, requiring hours of scanning time to generate full cross-sectional and/or axial field distributions. Moreover, the lateral resolution of the field distribution image is dependent on the indexing steps between data points. Acoustography is an imaging process in which an acousto-optical (AO area sensor is employed to record the intensity of an ultrasound wavefield on a two-dimensional plane. This paper reports on the application of acoustography as a simple but practical method for assessing transducer field characteristics. A case study performed on a commercial transducer is reported, where the radiated fields are imaged using acoustography and compared to the corresponding quantities that are predicted numerically.

  15. Influence of resonant transducer variations on long range guided wave monitoring of rail track

    Science.gov (United States)

    Loveday, Philip W.; Long, Craig S.

    2016-02-01

    The ability of certain guided wave modes to propagate long distances in continuously welded rail track is exploited in permanently installed monitoring systems. Previous work demonstrated that reflections from thermite welds could be measured at distances of the order of 1 km from a transducer array. The availability of numerous thermite welds is useful during the development of a monitoring system as real defects are not available. Measurements of reflections from welds were performed over an eleven month period with two permanently installed transducers. Phased array processing was performed and the true location of a weld is indicated by a strong reflection but there is generally also a smaller, spurious replica reflection, at the same distance but in the incorrect direction. In addition, the relative reflection from different welds appears to change over time. The influence of differences between the two resonant transducers was investigated using a model. It was found that estimating the attenuation in either direction and scaling the reflections in either direction decreased the variability in the reflection measurements. Transducer interaction effects, where the transducer closer to the weld records a greater reflection than the second transducer were observed and can be used to determine the direction of a weld. This feature was used to demonstrate a simple alternative to phased array processing that can be used with resonant transducers.

  16. Characterization of Dielectric Electroactive Polymer transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis; Møller, Martin B.; Sarban, Rahimullah

    2014-01-01

    This paper analysis the small-signal model of the Dielectric Electro Active Polymer (DEAP) transducer. The DEAP transducer have been proposed as an alternative to the electrodynamic transducer in sound reproduction systems. In order to understand how the DEAP transducer works, and provide guideli...

  17. Ultrasonic Transducer Irradiation Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Daw, Joshua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Palmer, Joe [Idaho National Lab. (INL), Idaho Falls, ID (United States); Ramuhalli, Pradeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Keller, Paul [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Montgomery, Robert [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chien, Hual-Te [Argonne National Lab. (ANL), Argonne, IL (United States); Kohse, Gordon [MIT (Massachusetts Inst. of Technology), Cambridge, MA (United States); Tittmann, Bernhard [Pennsylvania State Univ., University Park, PA (United States); Reinhardt, Brian [Pennsylvania State Univ., University Park, PA (United States); Rempe, Joy [Rempe and Associates, Idaho Falls, ID (United States)

    2015-02-01

    Ultrasonic technologies offer the potential for high-accuracy and -resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other ongoing efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. For this reason, the Pennsylvania State University (PSU) was awarded an ATR NSUF project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2. The goal of this research is to characterize and demonstrate magnetostrictive and piezoelectric transducer operation during irradiation, enabling the development of novel radiation-tolerant ultrasonic sensors for use in Material Testing Reactors (MTRs). As such, this test is an instrumented lead test and real-time transducer performance data is collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers. To date, one piezoelectric

  18. Systematic comparison of the use of annular and Zernike circle polynomials for annular wavefronts.

    Science.gov (United States)

    Mahajan, Virendra N; Aftab, Maham

    2010-11-20

    The theory of wavefront analysis of a noncircular wavefront is given and applied for a systematic comparison of the use of annular and Zernike circle polynomials for the analysis of an annular wavefront. It is shown that, unlike the annular coefficients, the circle coefficients generally change as the number of polynomials used in the expansion changes. Although the wavefront fit with a certain number of circle polynomials is identically the same as that with the corresponding annular polynomials, the piston circle coefficient does not represent the mean value of the aberration function, and the sum of the squares of the other coefficients does not yield its variance. The interferometer setting errors of tip, tilt, and defocus from a four-circle-polynomial expansion are the same as those from the annular-polynomial expansion. However, if these errors are obtained from, say, an 11-circle-polynomial expansion, and are removed from the aberration function, wrong polishing will result by zeroing out the residual aberration function. If the common practice of defining the center of an interferogram and drawing a circle around it is followed, then the circle coefficients of a noncircular interferogram do not yield a correct representation of the aberration function. Moreover, in this case, some of the higher-order coefficients of aberrations that are nonexistent in the aberration function are also nonzero. Finally, the circle coefficients, however obtained, do not represent coefficients of the balanced aberrations for an annular pupil. The various results are illustrated analytically and numerically by considering an annular Seidel aberration function.

  19. Non newtonian annular alloy solidification in mould

    Energy Technology Data Exchange (ETDEWEB)

    Moraga, Nelson O.; Garrido, Carlos P. [Universidad de La Serena, Departamento de Ingenieria Mecanica, La Serena (Chile); Castillo, Ernesto F. [Universidad de Santiago de Chile, Departamento de Ingenieria Mecanica, Santiago (Chile)

    2012-08-15

    The annular solidification of an aluminium-silicon alloy in a graphite mould with a geometry consisting of horizontal concentric cylinders is studied numerically. The analysis incorporates the behavior of non-Newtonian, pseudoplastic (n=0.2), Newtonian (n=1), and dilatant (n=1.5) fluids. The fluid mechanics and heat transfer coupled with a transient model of convection diffusion are solved using the finite volume method and the SIMPLE algorithm. Solidification is described in terms of a liquid fraction of a phase change that varies linearly with temperature. The final results make it possible to infer that the fluid dynamics and heat transfer of solidification in an annular geometry are affected by the non-Newtonian nature of the fluid, speeding up the process when the fluid is pseudoplastic. (orig.)

  20. Non Newtonian annular alloy solidification in mould

    Science.gov (United States)

    Moraga, Nelson O.; Castillo, Ernesto F.; Garrido, Carlos P.

    2012-08-01

    The annular solidification of an aluminium-silicon alloy in a graphite mould with a geometry consisting of horizontal concentric cylinders is studied numerically. The analysis incorporates the behavior of non-Newtonian, pseudoplastic ( n = 0.2), Newtonian ( n = 1), and dilatant ( n = 1.5) fluids. The fluid mechanics and heat transfer coupled with a transient model of convection diffusion are solved using the finite volume method and the SIMPLE algorithm. Solidification is described in terms of a liquid fraction of a phase change that varies linearly with temperature. The final results make it possible to infer that the fluid dynamics and heat transfer of solidification in an annular geometry are affected by the non-Newtonian nature of the fluid, speeding up the process when the fluid is pseudoplastic.

  1. Capacitive micromachined ultrasonic transducers (CMUTs) for photoacoustic imaging

    Science.gov (United States)

    Vaithilingam, Srikant; Wygant, Ira O.; Kuo, Paulina S.; Zhuang, Xuefeng; Oralkan, Ömer; Olcott, Peter D.; Khuri-Yakub, Butrus T.

    2006-02-01

    In photoacoustic (optoacoustic) medical imaging, short laser pulses irradiate absorbing structures found in tissue, such as blood vessels, causing brief thermal expansions that in turn generate ultrasound waves. These ultrasound waves which correspond to the optical absorption distribution were imaged using a two dimensional array of capacitive micromachined ultrasonic transducers (CMUTs). Advantages of CMUT technology for photoacoustic imaging include the ease of integration with electronics, ability to fabricate large two dimensional arrays, arrays with arbitrary geometries, wide-bandwidth arrays and high-frequency arrays. In this study, a phantom consisting of three 0.86-mm inner diameter polyethylene tubes inside a tissue mimicking material was imaged using a 16 x 16 element CMUT array. The center tube was filled with India-ink to provide optical contrast. Traditional pulse-echo data as well as photoacoustic image data were taken. 2D cross-sectional slices and 3D volume rendered images are shown. Simple array tiling was attempted, whereby a 48 x 48 element array was simulated, to illustrate the advantages of larger arrays. Finally, the sensitivity of the photoacoustics setup to the concentration of ink in the tube was also explored. For the sensitivity experiment a different phantom consisting of only one 1.14-mm inner diameter polyethylene tube inside a tissue mimicking material was used. The concentration of the ink inside the tube was varied and images were taken.

  2. Annular flow film characteristics in variable gravity.

    Science.gov (United States)

    MacGillivray, Ryan M; Gabriel, Kamiel S

    2002-10-01

    Annular flow is a frequently occurring flow regime in many industrial applications. The need for a better understanding of this flow regime is driven by the desire to improve the design of many terrestrial and space systems. Annular two-phase flow occurs in the mining and transportation of oil and natural gas, petrochemical processes, and boilers and condensers in heating and refrigeration systems. The flow regime is also anticipated during the refueling of space vehicles, and thermal management systems for space use. Annular flow is mainly inertia driven with little effect of buoyancy. However, the study of this flow regime is still desirable in a microgravity environment. The influence of gravity can create an unstable, chaotic film. The absence of gravity, therefore, allows for a more stable and axisymmetric film. Such conditions allow for the film characteristics to be easily studied at low gas flow rates. Previous studies conducted by the Microgravity Research Group dealt with varying the gas or liquid mass fluxes at a reduced gravitational acceleration.(1,2) The study described here continues this work by examining the effect of changing the gravitational acceleration (hypergravity) on the film characteristics. In particular, the film thickness and the associated pressure drops are examined. The film thickness was measured using a pair of two-wire conductance probes. Experimental data was collected over a range of annular flow set points by changing the liquid and gas mass flow rates, the liquid-to-gas density ratio and the gravitational acceleration. The liquid-to-gas density ratio was varied by collecting data with helium-water and air-water at the same flow rates. The gravitational effect was examined by collecting data during the microgravity and pull-up (hypergravity) portions of the parabolic flights.

  3. Auto-positioning ultrasonic transducer system

    Science.gov (United States)

    Buchanan, Randy K. (Inventor)

    2010-01-01

    An ultrasonic transducer apparatus and process for determining the optimal transducer position for flow measurement along a conduit outer surface. The apparatus includes a transmitting transducer for transmitting an ultrasonic signal, said transducer affixed to a conduit outer surface; a guide rail attached to a receiving transducer for guiding movement of a receiving transducer along the conduit outer surface, wherein the receiving transducer receives an ultrasonic signal from the transmitting transducer and sends a signal to a data acquisition system; and a motor for moving the receiving transducer along the guide rail, wherein the motor is controlled by a controller. The method includes affixing a transmitting transducer to an outer surface of a conduit; moving a receiving transducer on the conduit outer surface, wherein the receiving transducer is moved along a guide rail by a motor; transmitting an ultrasonic signal from the transmitting transducer that is received by the receiving transducer; communicating the signal received by the receiving transducer to a data acquisition and control system; and repeating the moving, transmitting, and communicating along a length of the conduit.

  4. Design of an ultrasonic micro-array for near field sensing during retinal microsurgery.

    Science.gov (United States)

    Clarke, Clyde; Etienne-Cummings, Ralph

    2006-01-01

    A method for obtaining the optimal and specific sensor parameters for a tool-tip mountable ultrasonic transducer micro-array is presented. The ultrasonic transducer array sensor parameters, such as frequency of operation, element size, inter-element spacing, number of elements and transducer geometry are obtained using a quadratic programming method to obtain a maximum directivity while being constrained to a total array size of 4 mm2 and the required resolution for retinal imaging. The technique is used to design a uniformly spaced NxN transducer array that is capable of resolving structures in the retina that are as small as 2 microm from a distance of 100 microm. The resultant 37x37 array of 16 microm transducers with 26 microm spacing will be realized as a Capacitive Micromachined Ultrasonic Transducer (CMUT) array and used for imaging and robotic guidance during retinal microsurgery.

  5. Annular feed air breathing fuel cell stack

    Science.gov (United States)

    Wilson, Mahlon S.; Neutzler, Jay K.

    1997-01-01

    A stack of polymer electrolyte fuel cells is formed from a plurality of unit cells where each unit cell includes fuel cell components defining a periphery and distributed along a common axis, where the fuel cell components include a polymer electrolyte membrane, an anode and a cathode contacting opposite sides of the membrane, and fuel and oxygen flow fields contacting the anode and the cathode, respectively, wherein the components define an annular region therethrough along the axis. A fuel distribution manifold within the annular region is connected to deliver fuel to the fuel flow field in each of the unit cells. The fuel distribution manifold is formed from a hydrophilic-like material to redistribute water produced by fuel and oxygen reacting at the cathode. In a particular embodiment, a single bolt through the annular region clamps the unit cells together. In another embodiment, separator plates between individual unit cells have an extended radial dimension to function as cooling fins for maintaining the operating temperature of the fuel cell stack.

  6. Calculations for Piezoelectric Ultrasonic Transducers

    DEFF Research Database (Denmark)

    Jensen, Henrik

    1986-01-01

    Analysis of piezoelectric ultrasonic transducers implies a solution of a boundary value problem, for a boay which consists of different materials, including a piezoelectric part. The problem is dynamic at frequencies, where a typical wavelength is somewhat less than the size of the body. Radiation...... and in particular the finite element method are considered. The finite element method is utilized for analysis of axisymmetric transducers. An explicit, fully piezoelectric, triangular ring element, with linear variations in displacememnt and electric potential is given. The influence of a fluid half-space is also...

  7. Rugged Direct-Current Transducer

    Science.gov (United States)

    Mclyman, W. T.

    1991-01-01

    Direct-current transducer withstands thermal and mechanical shocks. Operates from single, nominally 15-V power supply and nearly insensitive to both large variations in temperature and variations of as much as plus or minus 5 V in supply voltage. Its output voltage highly linear function of sensed current, with full-scale value of about 3 Vdc and offset of about 0.1 Vdc at 0 sensed current. Ruggedness of transducer due in large part to novel magnetic core, machined from solid block of nickel/iron high-permeability, low-hysteresis alloy.

  8. Development of a Flexible Broadband Rayleigh Waves Comb Transducer with Nonequidistant Comb Interval for Defect Detection of Thick-Walled Pipelines

    Science.gov (United States)

    He, Cunfu; Yan, Lyu; Zhang, Haijun

    2018-01-01

    It is necessary to develop a transducer that can quickly detect the inner and outer wall defects of thick-walled pipes, in order to ensure the safety of such pipes. In this paper, a flexible broadband Rayleigh-waves comb transducer based on PZT (lead zirconate titanate) for defect detection of thick-walled pipes is studied. The multiple resonant coupling theory is used to expand the transducer broadband and the FEA (Finite Element Analysis) method is used to optimize transducer array element parameters. Optimization results show that the best array element parameters of the transducer are when the transducer array element length is 30 mm, the thickness is 1.2 mm, the width of one end of is 1.5 mm, and the other end is 3 mm. Based on the optimization results, such a transducer was fabricated and its performance was tested. The test results were consistent with the finite-element simulation results, and the −3 dB bandwidth of the transducer reached 417 kHz. Transducer directivity test results show that the Θ−3dB beam width was equal to 10 °, to meet the defect detection requirements. Finally, defects of thick-walled pipes were detected using the transducer. The results showed that the transducer could detect the inner and outer wall defects of thick-walled pipes within the bandwidth. PMID:29498636

  9. Irradiation Testing of Ultrasonic Transducers

    International Nuclear Information System (INIS)

    Daw, J.; Rempe, J.; Palmer, J.; Tittmann, B.; Reinhardt, B.; Kohse, G.; Ramuhalli, P.; Montgomery, R.; Chien, H.T.; Villard, J.F.

    2013-06-01

    Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of numerous parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 10 21 n/cm 2 (E> 0.1 MeV). This test will be an instrumented lead test; and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. By characterizing magnetostrictive and piezoelectric transducer survivability during irradiation, test results will enable the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers. (authors)

  10. Granuloma annulare localized to the shaft of the penis

    DEFF Research Database (Denmark)

    Trap, R; Wiebe, B

    1993-01-01

    A case of granuloma annulare localized to the shaft of the penis is reported. The differential diagnoses are discussed. Penile granuloma annulare is a rare disorder and it is concluded that biopsies of penile lesions are recommended to verify the correct diagnosis.......A case of granuloma annulare localized to the shaft of the penis is reported. The differential diagnoses are discussed. Penile granuloma annulare is a rare disorder and it is concluded that biopsies of penile lesions are recommended to verify the correct diagnosis....

  11. Study on two phase flow characteristics in annular pulsed extraction column with different ratio of annular width to column diameter

    International Nuclear Information System (INIS)

    Qin Wei; Dai Youyuan; Wang Jiading

    1994-01-01

    Annular pulsed extraction column can successfully provide large throughput and can be made critically safe for fuel reprocessing. This investigation is to study the two phase flow characteristics in annular pulsed extraction column with four different annular width. 30% TBP (in kerosene)-water is used (water as continuous phase). Results show that modified Pratt correlation is valid under the experimental operation conditions for the annular pulsed extraction column. The characteristic velocity U K decreased with the increase of energy input and increased with the increase of the ratio of annular width to column diameter. Flooding velocity correlation is suggested. The deviation of the calculated values from the experimental data is within +20% for four annular width in a pulsed extraction column

  12. A New Annular Shear Piezoelectric Accelerometer

    DEFF Research Database (Denmark)

    Liu, Bin; Kriegbaum, B.

    2000-01-01

    prototype. Reasonable agreement between the experimental results of the physical prototype and the simulation results is achieved. The design becomes more efficient. In addition, Type 4511 has a built in DeltaTronâ charge amplifier with ID and complies with IEEE-P1451.4 standard, which is a smart transducer...

  13. A New Annular Shear Piezoelectric Accelerometer

    DEFF Research Database (Denmark)

    Liu, Bin; Kriegbaum, B.

    2000-01-01

    This paper describes the construction and performance of a recently introduced Annular Shear piezoelectric accelerometer, Type 4511. The design has insulated and double-shielded case. The accelerometer housing is made of stainless steel, AISI 316L. Piezoceramic PZ23 is used. The seismic mass...... is made of tungsten. All processes and materials comply with MIL-STD-11268. The mounted resonance frequency exceeds 40kHz. The sensitivity is 10mV/g ±5%. During the design process, the new design is evaluated and sufficiently optimized by using the Finite Element (FE) simulation before making actual...

  14. Wave turbulence in annular wave tank

    Science.gov (United States)

    Onorato, Miguel; Stramignoni, Ettore

    2014-05-01

    We perform experiments in an annular wind wave tank at the Dipartimento di Fisica, Universita' di Torino. The external diameter of the tank is 5 meters while the internal one is 1 meter. The tank is equipped by two air fans which can lead to a wind of maximum 5 m/s. The present set up is capable of studying the generation of waves and the development of wind wave spectra for large duration. We have performed different tests including different wind speeds. For large wind speed we observe the formation of spectra consistent with Kolmogorv-Zakharov predictions.

  15. Binary breeder reactor with annular core

    International Nuclear Information System (INIS)

    Nascimento, J.A. do; Ishiguro, Y.

    1988-01-01

    Characteristics of a 1200 MWe binary breeder reactor with annular core fueled with metallic 233 U- 238 U-Zr, Pu- 238 U-Zr and Th in the blankets have been analyzed. The Doppler effect is small as expected in a metal fueled fast reactor. The sodium void reactivity is, in general, smaller than in homogeneous fast reactors fueled with metallic fuel and with 1 m core height. The worths of available control is high and there is a large shutdown margin throughout the operational cycle. There are flexibility in blankets fueling in the two cycles, uranium and thorium, with doubling times of about 20 years. (author) [pt

  16. EXPLOSION OF ANNULAR CHARGE ON DUSTY SURFASE

    Directory of Open Access Journals (Sweden)

    A. Levin Vladimir

    2017-01-01

    Full Text Available This problem is related to the safety problem in the area of forest fires. It is well known that is possible to extinguish a fire, for example, by means of a powerful air stream. Such flow arises from the explosive shock wave. To enhance the im- pact of the blast wave can be used an explosive charge of annular shape. The shock wave, produced by the explosion, in- creased during moves to the center and can serve as a means of transportation dust in the seat of the fire. In addition, emerging after the collapse of a converging shock wave strong updraft can raise dust on a greater height and facilitate fire extinguishing, precipitating dust over a large area. This updraft can be dangerous for aircraft that are in the sky above the fire. To determine the width and height of the danger zone performed the numerical simulation of the ring of the explosion and the subsequent movement of dust and gas mixtures. The gas is considered ideal and perfect. The explosion is modeled as an instantaneous increase in the specific internal energy in an annular zone on the value of the specific heat of explosives. The flow is consid- ered as two-dimensional, and axisymmetric. The axis of symmetry perpendicular to the Earth surface. This surface is considered to be absolutely rigid and is considered as the boundary of the computational domain. On this surface is exhibited the condition of no motion. For the numerical method S. K. Godunov is used a movable grid. One system of lines of this grid is moved in accordance with movement of the shock wave. Others lines of this grid are stationary. The calculations were per- formed for different values of the radii of the annular field and for different sizes of rectangular cross-sectional of the annular field. Numerical results show that a very strong flow is occurring near the axis of symmetry and the particles rise high above the surface. These calculations allow us to estimate the sizes of the zone of danger in specific

  17. Annular Lupus Vulgaris Mimicking Tinea Cruris

    Science.gov (United States)

    Heo, Young Soo; Shin, Won Woong; Kim, Yong Ju; Song, Hae Jun

    2010-01-01

    Cutaneous tuberculosis is an infrequent form of extrapulmonary tuberculosis. It is often clinically and histopathologically confused with various cutaneous disorders. A 36-year-old man attended our clinic with slowly progressive, asymptomatic, annular skin lesions on both the thighs and buttocks for 10 years. He consulted with many physicians and was improperly treated with an oral antifungal agent for several months under the diagnosis of tinea cruris, but no resolution of his condition was observed. A diagnosis of lupus vulgaris was made based on the histopathologic examination and the polymerase chain reaction assay. Anti-tuberculosis therapy was administered and the lesions started to regress. PMID:20548922

  18. A Direct Driver for Electrostatic Transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    Electrostatic transducers represent a very interesting alternative to the traditional inefficient electrodynamic transducers. In order to establish the full potential of these transducers, power amplifiers which fulfill the strict requirements imposed by such loads (high impedance, frequency...... depended, nonlinear and high bias voltage for linearization) must be developed. This paper analyzes a power stage suitable for driving an electrostatic transducer under biasing. Measurement results of a ±400 V prototype amplifier are shown. THD below 1% is reported....

  19. The second annular pulley: a histologic examination.

    Science.gov (United States)

    Ellis, F D; Seiler, J G; Sewell, C W

    1995-07-01

    The second annular pulley and underlying flexor tendons from 15 fresh frozen fingers were prepared, sectioned transversely and longitudinally and then stained with hematoxylin-eosin, Verhoeff-Van Gieson (Elastin), Masson's trichrome and for the presence of hyaluronic acid. Three discrete layers of the second annular pulley were identified (1) an outer layer, continuous with the membranous sheath, that was richly vascularized; (2) a middle layer, characterized by radially oriented collagen fibrils and significant elastin fibrils; (3) an inner gliding surface, characterized by longitudinally oriented collagen fibrils and modified fibroblasts secreting hyaluronic acid. The three layers of the pulley seem specialized and have developed based on the functional requirements of the pulley apparatus. The outer layer serves as a source of vascular supply and nutrition, the middle layer maintains structural integrity and is organized to efficiently resist flexor tendon bowstringing, and the innermost layer facilitates efficient excursion of the underlying flexor tendons both by the orientation of the collagen fibers and by the secretion of substances that are thought to minimize friction.

  20. Studies on coaxial circular array for underwater transducer applications

    Digital Repository Service at National Institute of Oceanography (India)

    Chakraborty, B

    stream_size 1 stream_content_type text/plain stream_name J_Acoust_Soc_Am_89_p.946.pdf.txt stream_source_info J_Acoust_Soc_Am_89_p.946.pdf.txt Content-Encoding ISO-8859-1 Content-Type text/plain; charset=ISO-8859-1 ...

  1. Comparative Study on Ultrasonic Imaging Methods with Array Transducers

    Science.gov (United States)

    Matsuoka, C.; Nakahata, K.; Baba, A.; Kono, N.; Hirose, S.

    2008-02-01

    The performance of ultrasonic imaging methods developed in time domain and frequency domain algorithms is investigated in this study. The sectorial synthetic aperture focusing technique (S-SAFT) outputs the flaw image by superposing the sector-scan images obtained at various measurement points in the time domain. The inverse scattering imaging method (ISIM) is based on the elastodynamic inversion in the frequency domain and reconstructs the mathematical function which represents the flaw shape. The advantages and usabilities of these methods are discussed, taking into account the practical application to the NDE field.

  2. Multi Resonance Shear Mode Transducers

    Science.gov (United States)

    2016-11-21

    engineering in the single crystal lead magnesium niobate-lead titanate (PMNT) system has uncovered a very unique piezoelectric shear mode. Contrary to...ABSTRACT Crystallographic engineering of single crystal relaxor-based ferroelectrics was used to design broadband, compact, high power, low frequency...utilize the d36 shear piezoelectric coefficient, which has advantages for compact low frequency sonar transducers. The d36 cut is unique in that large

  3. Superconducting Qubit Optical Transducer (SQOT)

    Science.gov (United States)

    2015-08-05

    has photon loss in the optical fibre would appear has an effective T1 process and destroy any entanglement. 2.2.3 TEMPORAL MODE FILTER FUNCTION To...SECURITY CLASSIFICATION OF: The SQOT (Superconducting Qubit Optical Transducer) project proposes to build a novel electro- optic system which can...exchange quantum information between optical qubits at telecom frequencies and superconducting qubits. A direct quantum information transfer between

  4. Optical transducers with frequency output

    Science.gov (United States)

    Osadchuk, Oleksandr V.; Osadchuk, Volodymyr S.; Osadchuk, Iaroslav O.; Kolimoldayev, Maksat; Komada, Paweł; Mussabekov, Kanat

    2017-08-01

    In this work the characteristics research of microelectronic transducers of optical radiation with a frequency output signal on the basis of a hybrid integrated circuit consisting of a bipolar and a field-effect transistor with a Schottky barrier is presented. The connection of an external inductance to electrodes a collector - drain allows to implement the auto generating device. The frequency of the device generation depends on power of optical radiation falling on photosensing elements as a photoresistor, photodiode and photosensing transistors switched on in a circuit of the self-excited oscillator. The impedance on electrodes the collector - drain of bipolar and field transistors has capacitive reactive part and negative active resistance, which compensates power losses in a tuning circuit of the device. On the base of a nonlinear equivalent circuit of the transducer on an alternating current the analytical expressions of function of transformation and equation of sensitivity are obtained. The sensitivity of optical transducers lays in a range from 25 kHz/μWt/cm2 up to 150 kHz/μWt/cm2.

  5. Calculations for piezoelectric ultrasonic transducers

    International Nuclear Information System (INIS)

    Jensen, H.

    1986-05-01

    Analysis of piezoelectric ultrasonic transducers implies a solution of a boundary value problem, for a body which consists of different materials, including a piezoelectric part. The problem is dynamic at frequencies, where a typical wavelength is somewhat less than the size of the body. Radiation losses as well as internal losses may be important. Due to the complexity of the problem, a closed form solution is the exception rather than the rule. For this reason, it is necessary to use approximate methods for the analysis. Equivalent circuits, the Rayleigh-Ritz method, Mindlin plate theory and in particular the finite element method are considered. The finite element method is utilized for analysis of axisymmetric transducers. An explicit, fully piezoelectric, triangular ring element, with linear variations in displacement and electric potential is given. The influence of a fluid half-space is also given, in the form of a complex stiffness matrix. A special stacking procedure, for analysis of the backing has been developed. This procedure gives a saving, which is similar to that of the fast fourier transform algorithm, and is also wellsuited for analysis of finite and infinite waveguides. Results obtained by the finite element method are shown and compared with measurements and exact solutions. Good agreement is obtained. It is concluded that the finite element method can be a valueable tool in analysis and design of ultrasonic transducers. (author)

  6. Linear sloshing frequencies in the annular region of a circular ...

    Indian Academy of Sciences (India)

    Sloshing in any type of container may invite instability to it. If some part of the free liquid surface in the annular region of a specially designed circular cylindrical container is covered with an annular baffle, the natural frequencies and the response of the liquid in the container undergo a drastic change. A partly covered free ...

  7. Obtention of an empirical equation for annular channels

    International Nuclear Information System (INIS)

    Diaz H, C.; Salinas R, G.A.

    1996-01-01

    Using a trial circuit, the experimental heat transfer coefficient is determined, in forced convection at one phase only within an annular channel in which water flows ascendantly and for this reason an empirical equation is determined. This work tries to contribute to the understanding of the forced convection phenomena in non tubular geometries like the annular channels. (Author)

  8. Capacitive micromachined ultrasonic transducers for medical imaging and therapy

    Science.gov (United States)

    Khuri-Yakub, Butrus T.; Oralkan, Ömer

    2011-05-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have been subject to extensive research for the last two decades. Although they were initially developed for air-coupled applications, today their main application space is medical imaging and therapy. This paper first presents a brief description of CMUTs, their basic structure and operating principles. Our progression of developing several generations of fabrication processes is discussed with an emphasis on the advantages and disadvantages of each process. Monolithic and hybrid approaches for integrating CMUTs with supporting integrated circuits are surveyed. Several prototype transducer arrays with integrated front-end electronic circuits we developed and their use for 2D and 3D, anatomical and functional imaging, and ablative therapies are described. The presented results prove the CMUT as a micro-electro-mechanical systems technology for many medical diagnostic and therapeutic applications.

  9. Capacitive micromachined ultrasonic transducers for medical imaging and therapy

    International Nuclear Information System (INIS)

    Khuri-Yakub, Butrus T; Oralkan, Ömer

    2011-01-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have been subject to extensive research for the last two decades. Although they were initially developed for air-coupled applications, today their main application space is medical imaging and therapy. This paper first presents a brief description of CMUTs, their basic structure and operating principles. Our progression of developing several generations of fabrication processes is discussed with an emphasis on the advantages and disadvantages of each process. Monolithic and hybrid approaches for integrating CMUTs with supporting integrated circuits are surveyed. Several prototype transducer arrays with integrated front-end electronic circuits we developed and their use for 2D and 3D, anatomical and functional imaging, and ablative therapies are described. The presented results prove the CMUT as a micro-electro-mechanical systems technology for many medical diagnostic and therapeutic applications

  10. Transducers

    Digital Repository Service at National Institute of Oceanography (India)

    Chakraborty, B.

    stream_size 27 stream_content_type text/plain stream_name Encycl_Microcomputers_18_335.pdf.txt stream_source_info Encycl_Microcomputers_18_335.pdf.txt Content-Encoding ISO-8859-1 Content-Type text/plain; charset=ISO-8859-1 ...

  11. The Liquid Annular Reactor System (LARS) propulsion

    International Nuclear Information System (INIS)

    Powell, J.; Ludewig, H.; Horn, F.; Lenard, R.

    1990-01-01

    A concept for very high specific impulse (greater than 2000 seconds) direct nuclear propulsion is described. The concept, termed the liquid annular reactor system (LARS), uses liquid nuclear fuel elements to heat hydrogen propellant to very high temperatures (approximately 6000 K). Operating pressure is moderate (approximately 10 atm), with the result that the outlet hydrogen is virtually 100 percent dissociated to monatomic H. The molten fuel is contained in a solid container of its own material, which is rotated to stabilize the liquid layer by centripetal force. LARS reactor designs are described, together with neutronic and thermal-hydraulic analyses. Power levels are on the order of 200 megawatts. Typically, LARS designs use seven rotating fuel elements, are beryllium moderated, and have critical radii of approximately 100 cm (core L/D approximately equal to 1.5)

  12. Hydrodynamics of annular-dispersed flow

    International Nuclear Information System (INIS)

    Ishii, M.; Kataoka, I.

    1982-01-01

    The interfacial drag, droplet entrainment, and droplet size distributions are important for detailed mechanistic modeling of annular dispersed two-phase flow. In view of this, recently developed correlations for these parameters are presented and discussed in this paper. The drag correlations for multiple fluid particle systems have been developed from a similarity hypothesis based on the mixture viscosity model. The results show that the drag coefficient depends on the particle Reynolds number and droplet concentration. The onset on droplet entrainment significantly alters the mechanisms of mass, momentum, and energy transfer between the film and gas core flow as well as the transfer between the two-phase mixture and the wall. By assuming the roll wave entrainment mechanism, the correlations for the amount of entrained droplet as well as for the droplet size distribution have been obtained from a simple model in collaboration with a large number of data

  13. Analytical modeling of inverted annular film boiling

    International Nuclear Information System (INIS)

    Analytis, G.T.; Yadigaroglu, G.

    1987-01-01

    By employing a two-fluid formulation similar to the one used in the most recent LWR accident analysis codes, a model for the Inverted Annular Film Boiling region is developed. The conservation equations, together with appropriate closure relations are solved numerically. Successful comparisons are made between model predictions and heat transfer coefficient distributions measured in a series of single-tube reflooding experiments. Generally, the model predicts correctly the dependence of the heat transfer coefficient on liquid subcooling and flow rate; for some cases, however, heat transfer is still under-predicted, and an enhancement of the heat exchange from the liquid-vapour interface to the bulk of the liquid is required. The importance of the initial conditions at the quench front is also discussed. (orig.)

  14. Analytical modeling of inverted annular film boiling

    International Nuclear Information System (INIS)

    Analytis, G.T.; Yadigaroglu, G.

    1985-01-01

    By employing a two-fluid formulation similar to the one used in the most recent LWR accident analysis codes, a model for the Inverted Annular Film Boiling region is developed. The conservation equations, together with appropriate constitutive relations are solved numerically and successful comparisons are made between model predictions and heat transfer coefficient distributions measured in a series of single-tube reflooding experiments. The model predicts generally correctly the dependence of the heat transfer coefficient on liquid subcooling and flow rate, through, for some cases, heat transfer is still under-predicted, and an enhancement of the heat exchange from the liquid-vapour interface to the bulk of the liquid is required

  15. Annular MHD Physics for Turbojet Energy Bypass

    Science.gov (United States)

    Schneider, Steven J.

    2011-01-01

    The use of annular Hall type MHD generator/accelerator ducts for turbojet energy bypass is evaluated assuming weakly ionized flows obtained from pulsed nanosecond discharges. The equations for a 1-D, axisymmetric MHD generator/accelerator are derived and numerically integrated to determine the generator/accelerator performance characteristics. The concept offers a shockless means of interacting with high speed inlet flows and potentially offers variable inlet geometry performance without the complexity of moving parts simply by varying the generator loading parameter. The cycle analysis conducted iteratively with a spike inlet and turbojet flying at M = 7 at 30 km altitude is estimated to have a positive thrust per unit mass flow of 185 N-s/kg. The turbojet allowable combustor temperature is set at an aggressive 2200 deg K. The annular MHD Hall generator/accelerator is L = 3 m in length with a B(sub r) = 5 Tesla magnetic field and a conductivity of sigma = 5 mho/m for the generator and sigma= 1.0 mho/m for the accelerator. The calculated isentropic efficiency for the generator is eta(sub sg) = 84 percent at an enthalpy extraction ratio, eta(sub Ng) = 0.63. The calculated isentropic efficiency for the accelerator is eta(sub sa) = 81 percent at an enthalpy addition ratio, eta(sub Na) = 0.62. An assessment of the ionization fraction necessary to achieve a conductivity of sigma = 1.0 mho/m is n(sub e)/n = 1.90 X 10(exp -6), and for sigma = 5.0 mho/m is n(sub e)/n = 9.52 X 10(exp -6).

  16. LAVA Pressure Transducer Trade Study

    Science.gov (United States)

    Oltman, Samuel B.

    2016-01-01

    The Regolith and Environment Science and Oxygen and Lunar Volatile Extraction (RESOLVE) payload will transport the (LAVA) subsystem to hydrogen-rich locations on the moon supporting NASA's in-situ resource utilization (ISRU) programs. There, the LAVA subsystem will analyze volatiles that evolve from heated regolith samples in order to quantify how much water is present. To do this, the system needs resilient pressure transducers (PTs) to calculate the moles in the gas samples. The PT trade study includes a comparison of newly-procured models to a baseline unit with prior flight history in order to determine the PT model with the best survivability in flight-forward conditions.

  17. Phase-locking of annular-combination CO2 laser

    Science.gov (United States)

    Qi, Tingxiang; Chen, Mei; Zhang, Rongzhu; Xiao, Qianyi

    2015-07-01

    A new annular-combination resonator structure adopting the external-injection phase-locking technology is presented theoretically for that the beam quality of stable annular resonator is not satisfying. The phase-locking principle and feasibility are characterized by energy density of injection beam and coupling coefficient. Based on the diffraction theory, output mode of the resonator with phase-locking is deduced and simulated. Results also confirm that injection beam have a good control effect on output mode. The intensity distributions of output beam are studied briefly and indicate that this new resonator which is adaptable to annular gain media can produce high-power laser beam with high quality.

  18. Coexistence of morphea and granuloma annulare: a rare case report

    Directory of Open Access Journals (Sweden)

    Şenay Ağırgöl

    2017-11-01

    Full Text Available ABSTRACT CONTEXT: Localized scleroderma (morphea is characterized by fibrosis of skin and subcutaneous tissue. Granuloma annulare is a relatively common disease that is characterized by dermal papules and arciform plaques. CASE REPORT: Here, we present the case of a 42-year-old woman who developed granuloma annulare on the dorsum of her feet and abdominal region, and morphea on the anterior side of her lower limbs. We also discuss the etiological and pathogenetic processes that may cause the rare coexistence of these two diseases. CONCLUSION: Only a few cases in the literature have described coexistence of morphea and granuloma annulare.

  19. New technique for fabrication of high frequency piezoelectric Micromachined Ultrasound Transducers

    DEFF Research Database (Denmark)

    Pedersen, T; Thomsen, Erik Vilain; Zawada, T

    2008-01-01

    A novel technique for fabrication of linear arrays of high frequency piezoelectric Micromachined Ultrasound Transducers (pMUT) on silicon substrates is presented. Piezoelectric elements are formed by deposition of PZT ((PbZrxTi1-x)O3) into etched features of the silicon substrate...

  20. Performance of Honeywell silicon pressure transducers

    Digital Repository Service at National Institute of Oceanography (India)

    VijayKumar, K.; Joseph, A.; Desai, R.G.P.; Nagvekar, S.; Prabhudesai, S.; Damodaran, V.

    to elucidate the performance characteristics of the pressure transducer such as zero-point offset, standard deviation, hysteresis effect, linearity, accuracy, temperature-sensitivity, repeatability, and so forth. 3.1 Calibration Device In the present work... pressure transducers 184 the pressure-calibrator, whose output was considered as the true value of pressure. Amongst the currently available pressure standards, those that provide the finest pressure resolution are these quartz pressure transducers [3...

  1. Review of piezoelectric micromachined ultrasonic transducers and their applications

    Science.gov (United States)

    Jung, Joontaek; Lee, Wonjun; Kang, Woojin; Shin, Eunjung; Ryu, Jungho; Choi, Hongsoo

    2017-11-01

    In recent decades, micromachined ultrasonic transducers (MUTs) have been investigated as an alternative to conventional piezocomposite ultrasonic transducers, primarily due to the advantages that microelectromechanical systems provide. Miniaturized ultrasonic systems require ultrasonic transducers integrated with complementary metal-oxide-semiconductor circuits. Hence, piezoelectric MUTs (pMUTs) and capacitive MUTs (cMUTs) have been developed as the most favorable solutions. This paper reviews the basic equations to understand the characteristics of thin-film-based piezoelectric devices and presents recent research on pMUTs, including current approaches and limitations. Methods to improve the coupling coefficient of pMUTs are also investigated, such as device structure, materials, and fabrication techniques. The device structure improvements include multielectrode pMUTs, partially clamped boundary conditions, and 3D pMUTs (curved and domed types), where the latter can provide an electromechanical coupling coefficient of up to 45%. The piezoelectric coefficient (e 31) can be increased by controlling the crystal texture (seed layer of γ-Al2O3), using single-crystal (PMN-PT) materials, or control of residual stresses (using SiO2 layer). Arrays of pMUTs can be implemented for various applications including intravascular ultrasound, fingerprint sensors, rangefinders in air, and wireless power supply systems. pMUTs are expected to be an ideal solution for applications such as mobile biometric security (fingerprint sensors) and rangefinders due to their superior power efficiency and compact size.

  2. Review of piezoelectric micromachined ultrasonic transducers and their applications

    International Nuclear Information System (INIS)

    Jung, Joontaek; Lee, Wonjun; Kang, Woojin; Shin, Eunjung; Choi, Hongsoo; Ryu, Jungho

    2017-01-01

    In recent decades, micromachined ultrasonic transducers (MUTs) have been investigated as an alternative to conventional piezocomposite ultrasonic transducers, primarily due to the advantages that microelectromechanical systems provide. Miniaturized ultrasonic systems require ultrasonic transducers integrated with complementary metal-oxide-semiconductor circuits. Hence, piezoelectric MUTs (pMUTs) and capacitive MUTs (cMUTs) have been developed as the most favorable solutions. This paper reviews the basic equations to understand the characteristics of thin-film-based piezoelectric devices and presents recent research on pMUTs, including current approaches and limitations. Methods to improve the coupling coefficient of pMUTs are also investigated, such as device structure, materials, and fabrication techniques. The device structure improvements include multielectrode pMUTs, partially clamped boundary conditions, and 3D pMUTs (curved and domed types), where the latter can provide an electromechanical coupling coefficient of up to 45%. The piezoelectric coefficient ( e 31 ) can be increased by controlling the crystal texture (seed layer of γ -Al 2 O 3 ), using single-crystal (PMN-PT) materials, or control of residual stresses (using SiO 2 layer). Arrays of pMUTs can be implemented for various applications including intravascular ultrasound, fingerprint sensors, rangefinders in air, and wireless power supply systems. pMUTs are expected to be an ideal solution for applications such as mobile biometric security (fingerprint sensors) and rangefinders due to their superior power efficiency and compact size. (topical review)

  3. Capacitive micromachined ultrasonic transducers with through-wafer interconnects

    Science.gov (United States)

    Zhuang, Xuefeng

    Capacitive micromachined ultrasonic transducer (CMUT) is a promising candidate for making ultrasound transducer arrays for applications such as 3D medical ultrasound, non-destructive evaluation and chemical sensing. Advantages of CMUTs over traditional piezoelectric transducers include low-cost batch fabrication, wide bandwidth, and ability to fabricate arrays with broad operation frequency range and different geometric configurations on a single wafer. When incorporated with through-wafer interconnects, a CMUT array can be directly integrated with a front-end integrated circuit (IC) to achieve compact packaging and to mitigate the effects of the parasitic capacitance from the connection cables. Through-wafer via is the existing interconnect scheme for CMUT arrays, and many other types of micro-electro-mechanical system (MEMS) devices. However, to date, no successful through-wafer via fabrication technique compatible with the wafer-bonding method of making CMUT arrays has been demonstrated. The through-wafer via fabrication steps degrade the surface conditions of the wafer, reduce the radius of curvature, thus making it difficult to bond. This work focuses on new through-wafer interconnect techniques that are compatible with common MEMS fabrication techniques, including both surface-micromachining and direct wafer-to-wafer fusion bonding. In this dissertation, first, a through-wafer via interconnect technique with improved characteristics is presented. Then, two implementations of through-wafer trench isolation are demonstrated. The through-wafer trench methods differ from the through-wafer vias in that the electrical conduction is through the bulk silicon instead of the conductor in the vias. In the first implementation, a carrier wafer is used to provide mechanical support; in the second, mechanical support is provided by a silicon frame structure embedded inside the isolation trenches. Both implementations reduce fabrication complexity compared to the through

  4. Annular linear induction pump with an externally supported duct

    International Nuclear Information System (INIS)

    1980-01-01

    An annular linear induction pump of increased efficiency is described, capable of being readily disassembled for repair or replacement of parts, and having one pass flow of the liquid metal through the pump. (U.K.)

  5. Confocal retinal imaging using scanning laser opthalmoscopy with annular beams

    NARCIS (Netherlands)

    Vohnsen, Brian; Lochocki, Benjamin; Vela-Garcia, Carmen; Rativa, Diego

    2012-01-01

    The human retina has been imaged in-vivo using scanning laser ophthalmoscopy employing annular incident beams adapted for resolution optimization. The pros and cons of the approach are discussed and the importance of coherence is explored.

  6. Granuloma Annulare Skin Lesions in a Case of Sarcoidosis

    Science.gov (United States)

    Chopra, Ajay; Mitra, Debdeep; Sharma, Loknandini; Agarwal, Reetu

    2018-01-01

    We report the case of a 32-year- old man with a short 3-week history of erythematous, annular, non scaly plaques on palmar and dorsal aspect of his hands, who was concurrently diagnosed as a case of sarcoidosis on the basis of findings of generalized lymphadenopathy and radiological and histological features of pulmonary sarcoidosis. His skin biopsy was consistent with the diagnosis of granuloma annulare. Sarcoidosis and granuloma annulare are two separate diseases, which involve the skin and have a mononuclear histiocytic cellular reaction, although their aetiology is still unknown. Granuloma annulare has been associated with the concomitant diagnosis of sarcoidosis in only two more case reports and this association can be evaluated further to study a common link in the aetipathogenesis of these two granulomatous skin diseases.

  7. Interfacial friction in low flowrate vertical annular flow

    International Nuclear Information System (INIS)

    Kelly, J.M.; Freitas, R.L.

    1993-01-01

    During boil-off and reflood transients in nuclear reactors, the core liquid inventory and inlet flowrate are largely determined by the interfacial friction in the reactor core. For these transients, annular flow occurs at relatively modest liquid flowrates and at the low heat fluxes typical of decay heat conditions. The resulting low vapor Reynolds numbers, are out of the data range used to develop the generally accepted interfacial friction relations for annular flow. In addition, most existing annular flow data comes from air/liquid adiabatic experiments with fully developed flows. By contrast, in a reactor core, the flow is continuously developing along the heated length as the vapor flowrate increases and the flow regimes evolve from bubbly to annular flow. Indeed, the entire annular flow regime may exist only over tens of L/D's. Despite these limitations, many of the advanced reactor safety analysis codes employ the Wallis model for interfacial friction in annular flow. Our analyses of the conditions existing at the end-of-reflood in the PERICLES tests have indicated that the Wallis model seriously underestimates the interfacial shear for low vapor velocity cocurrent upflow. To extend the annular flow data base to diabatic low flowrate conditions, the DADINE tests were re-analyzed. In these tests, both pressure drop and local cross-section averaged void fractions were measured. Thus, both the wall and interfacial shear can be deduced. Based on the results of this analysis, a new correlation is proposed for interfacial friction in annular flow. (authors). 5 figs., 12 refs

  8. Acoustic backscatter and effective scatterer size estimates using a 2D CMUT transducer

    Energy Technology Data Exchange (ETDEWEB)

    Liu, W; Zagzebski, J A; Hall, T J; Madsen, E L; Varghese, T [Department of Medical Physics, University of Wisconsin-Madison, 1300 University Avenue, 1530 MSC, Madison, WI 53706 (United States); Kliewer, M A [Department of Radiology, University of Wisconsin-Madison, Madison, WI 53706 (United States); Panda, S; Lowery, C [Ultrasound Division, Siemens Medical Solutions USA, Inc., Issaquah, WA 98029 (United States); Barnes, S [Siemens Corporate Research, Inc., Issaquah, WA 98029 (United States)], E-mail: wuliu@stanford.edu, E-mail: jazagzeb@wisc.edu

    2008-08-07

    Compared to conventional piezoelectric transducers, new capacitive microfabricated ultrasonic transducer (CMUT) technology is expected to offer a broader bandwidth, higher resolution and advanced 3D/4D imaging inherent in a 2D array. For ultrasound scatterer size imaging, a broader frequency range provides more information on frequency-dependent backscatter, and therefore, generally more accurate size estimates. Elevational compounding, which can significantly reduce the large statistical fluctuations associated with parametric imaging, becomes readily available with a 2D array. In this work, we show phantom and in vivo breast tumor scatterer size image results using a prototype 2D CMUT transducer (9 MHz center frequency) attached to a clinical scanner. A uniform phantom with two 1 cm diameter spherical inclusions of slightly smaller scatterer size was submerged in oil and scanned by both the 2D CMUT and a conventional piezoelectric linear array transducer. The attenuation and scatterer sizes of the sample were estimated using a reference phantom method. RF correlation analysis was performed using the data acquired by both transducers. The 2D CMUT results indicate that at a 2 cm depth (near the transmit focus for both transducers) the correlation coefficient reduced to less than 1/e for 0.2 mm lateral or 0.25 mm elevational separation between acoustic scanlines. For the conventional array this level of decorrelation requires a 0.3 mm lateral or 0.75 mm elevational translation. Angular and/or elevational compounding is used to reduce the variance of scatterer size estimates. The 2D array transducer acquired RF signals from 140 planes over a 2.8 cm elevational direction. If no elevational compounding is used, the fractional standard deviation of the size estimates is about 12% of the mean size estimate for both the spherical inclusion and the background. Elevational compounding of 11 adjacent planes reduces it to 7% for both media. Using an experimentally estimated

  9. Acoustic backscatter and effective scatterer size estimates using a 2D CMUT transducer

    International Nuclear Information System (INIS)

    Liu, W; Zagzebski, J A; Hall, T J; Madsen, E L; Varghese, T; Kliewer, M A; Panda, S; Lowery, C; Barnes, S

    2008-01-01

    Compared to conventional piezoelectric transducers, new capacitive microfabricated ultrasonic transducer (CMUT) technology is expected to offer a broader bandwidth, higher resolution and advanced 3D/4D imaging inherent in a 2D array. For ultrasound scatterer size imaging, a broader frequency range provides more information on frequency-dependent backscatter, and therefore, generally more accurate size estimates. Elevational compounding, which can significantly reduce the large statistical fluctuations associated with parametric imaging, becomes readily available with a 2D array. In this work, we show phantom and in vivo breast tumor scatterer size image results using a prototype 2D CMUT transducer (9 MHz center frequency) attached to a clinical scanner. A uniform phantom with two 1 cm diameter spherical inclusions of slightly smaller scatterer size was submerged in oil and scanned by both the 2D CMUT and a conventional piezoelectric linear array transducer. The attenuation and scatterer sizes of the sample were estimated using a reference phantom method. RF correlation analysis was performed using the data acquired by both transducers. The 2D CMUT results indicate that at a 2 cm depth (near the transmit focus for both transducers) the correlation coefficient reduced to less than 1/e for 0.2 mm lateral or 0.25 mm elevational separation between acoustic scanlines. For the conventional array this level of decorrelation requires a 0.3 mm lateral or 0.75 mm elevational translation. Angular and/or elevational compounding is used to reduce the variance of scatterer size estimates. The 2D array transducer acquired RF signals from 140 planes over a 2.8 cm elevational direction. If no elevational compounding is used, the fractional standard deviation of the size estimates is about 12% of the mean size estimate for both the spherical inclusion and the background. Elevational compounding of 11 adjacent planes reduces it to 7% for both media. Using an experimentally estimated

  10. Acoustic backscatter and effective scatterer size estimates using a 2D CMUT transducer

    Science.gov (United States)

    Liu, W.; Zagzebski, J. A.; Hall, T. J.; Madsen, E. L.; Varghese, T.; Kliewer, M. A.; Panda, S.; Lowery, C.; Barnes, S.

    2008-08-01

    Compared to conventional piezoelectric transducers, new capacitive microfabricated ultrasonic transducer (CMUT) technology is expected to offer a broader bandwidth, higher resolution and advanced 3D/4D imaging inherent in a 2D array. For ultrasound scatterer size imaging, a broader frequency range provides more information on frequency-dependent backscatter, and therefore, generally more accurate size estimates. Elevational compounding, which can significantly reduce the large statistical fluctuations associated with parametric imaging, becomes readily available with a 2D array. In this work, we show phantom and in vivo breast tumor scatterer size image results using a prototype 2D CMUT transducer (9 MHz center frequency) attached to a clinical scanner. A uniform phantom with two 1 cm diameter spherical inclusions of slightly smaller scatterer size was submerged in oil and scanned by both the 2D CMUT and a conventional piezoelectric linear array transducer. The attenuation and scatterer sizes of the sample were estimated using a reference phantom method. RF correlation analysis was performed using the data acquired by both transducers. The 2D CMUT results indicate that at a 2 cm depth (near the transmit focus for both transducers) the correlation coefficient reduced to less than 1/e for 0.2 mm lateral or 0.25 mm elevational separation between acoustic scanlines. For the conventional array this level of decorrelation requires a 0.3 mm lateral or 0.75 mm elevational translation. Angular and/or elevational compounding is used to reduce the variance of scatterer size estimates. The 2D array transducer acquired RF signals from 140 planes over a 2.8 cm elevational direction. If no elevational compounding is used, the fractional standard deviation of the size estimates is about 12% of the mean size estimate for both the spherical inclusion and the background. Elevational compounding of 11 adjacent planes reduces it to 7% for both media. Using an experimentally estimated

  11. Integrated field emission array for ion desorption

    Energy Technology Data Exchange (ETDEWEB)

    Resnick, Paul J; Hertz, Kristin L.; Holland, Christopher; Chichester, David

    2016-08-23

    An integrated field emission array for ion desorption includes an electrically conductive substrate; a dielectric layer lying over the electrically conductive substrate comprising a plurality of laterally separated cavities extending through the dielectric layer; a like plurality of conically-shaped emitter tips on posts, each emitter tip/post disposed concentrically within a laterally separated cavity and electrically contacting the substrate; and a gate electrode structure lying over the dielectric layer, including a like plurality of circular gate apertures, each gate aperture disposed concentrically above an emitter tip/post to provide a like plurality of annular gate electrodes and wherein the lower edge of each annular gate electrode proximate the like emitter tip/post is rounded. Also disclosed herein are methods for fabricating an integrated field emission array.

  12. Sonographic evaluation of digital annular pulley tears

    International Nuclear Information System (INIS)

    Martinoli, C.; Derchi, L.E.; Bianchi, S.; Garcia, J.F.; Nebiolo, M.

    2000-01-01

    Objective. To evaluate the sonographic (US) appearance of digital annular pulley (DAP) tears in high-level rock climbers. Design and patients. We performed a retrospective analysis of the US examinations of 16 high-level rock climbers with clinical signs of DAP lesions. MRI and surgical evaluation were performed in five and three patients respectively. The normal US and MRI appearances of DAP were evaluated in 40 and three normal fingers respectively. Results. Nine of 16 patients presented a DAP tear. In eight subjects (seven with complete tears involving the fourth finger and one the fifth finger), US diagnosis was based on the indirect sign of volar bowstringing of the flexor tendons. Injured pulleys were not appreciated by US. Tears concerned the A2 and A3 in six patients and the A3 and A4 in two patients. A2 pulley thickening and hypoechogenicity compatible with a partial tear was demonstrated in one patient. MRI and surgical data correlated well with the US findings. Four patients had tenosynovitis of the flexor tendons but no evidence of pulley disruption. US examinations of three patients were normal. In the healthy subjects US demonstrated DAP in 16 of 40 digits. Conclusion. US can diagnose DAP tears and correlates with the MRI and surgical data. Because of its low cost and non-invasiveness we suggest US as the first imaging modality in the evaluation of injuries of the digital pulley. (orig.)

  13. Sonographic evaluation of digital annular pulley tears

    Energy Technology Data Exchange (ETDEWEB)

    Martinoli, C.; Derchi, L.E. [Istituto di Radiologia, Universita di Genova, Genoa (Italy); Bianchi, S.; Garcia, J.F. [Dept. de Radiologie, Hopital Cantonal Universitaire de Geneve (Switzerland); Nebiolo, M. [Reparto Pronto Soccorso Medico, Pietra Ligure (Italy)

    2000-07-01

    Objective. To evaluate the sonographic (US) appearance of digital annular pulley (DAP) tears in high-level rock climbers. Design and patients. We performed a retrospective analysis of the US examinations of 16 high-level rock climbers with clinical signs of DAP lesions. MRI and surgical evaluation were performed in five and three patients respectively. The normal US and MRI appearances of DAP were evaluated in 40 and three normal fingers respectively. Results. Nine of 16 patients presented a DAP tear. In eight subjects (seven with complete tears involving the fourth finger and one the fifth finger), US diagnosis was based on the indirect sign of volar bowstringing of the flexor tendons. Injured pulleys were not appreciated by US. Tears concerned the A2 and A3 in six patients and the A3 and A4 in two patients. A2 pulley thickening and hypoechogenicity compatible with a partial tear was demonstrated in one patient. MRI and surgical data correlated well with the US findings. Four patients had tenosynovitis of the flexor tendons but no evidence of pulley disruption. US examinations of three patients were normal. In the healthy subjects US demonstrated DAP in 16 of 40 digits. Conclusion. US can diagnose DAP tears and correlates with the MRI and surgical data. Because of its low cost and non-invasiveness we suggest US as the first imaging modality in the evaluation of injuries of the digital pulley. (orig.)

  14. Parametric Investigation of Miniaturized Cylindrical and Annular Hall Thrusters

    International Nuclear Information System (INIS)

    Smirnov, A.; Raitses, Y.; Fisch, N.J.

    2002-01-01

    Conventional annular Hall thrusters become inefficient when scaled to low power. An alternative approach, a 2.6-cm miniaturized cylindrical Hall thruster with a cusp-type magnetic field distribution, was developed and studied. Its performance was compared to that of a conventional annular thruster of the same dimensions. The cylindrical thruster exhibits discharge characteristics similar to those of the annular thruster, but it has a much higher propellant ionization efficiency. Significantly, a large fraction of multi-charged xenon ions might be present in the outgoing ion flux generated by the cylindrical thruster. The operation of the cylindrical thruster is quieter than that of the annular thruster. The characteristic peak in the discharge current fluctuation spectrum at 50-60 kHz appears to be due to ionization instabilities. In the power range 50-300 W, the cylindrical and annular thrusters have comparable efficiencies (15-32%) and thrusts (2.5-12 mN). For the annular configuration, a voltage less than 200 V was not sufficient to sustain the discharge at low propellant flow rates. The cylindrical thruster can operate at voltages lower than 200 V, which suggests that a cylindrical thruster can be designed to operate at even smaller power

  15. Opto-acoustic transducer for medical applications

    Science.gov (United States)

    Benett, W.; Celliers, P.; Da Silva, L.; Glinsky, M.; London, R.; Maitland, D.; Matthews, D.; Krulevich, P.; Lee, A.

    1999-08-31

    This invention is an optically activated transducer for generating acoustic vibrations in a biological medium. The transducer is located at the end of a fiber optic which may be located within a catheter. Energy for operating the transducer is provided optically by laser light transmitted through the fiber optic to the transducer. Pulsed laser light is absorbed in the working fluid of the transducer to generate a thermal pressure and consequent adiabatic expansion of the transducer head such that it does work against the ambient medium. The transducer returns to its original state by a process of thermal cooling. The motion of the transducer within the ambient medium couples acoustic energy into the medium. By pulsing the laser at a high repetition rate (which may vary from CW to 100 kHz) an ultrasonic radiation field can be established locally in the medium. This method of producing ultrasonic vibrations can be used in vivo for the treatment of stroke-related conditions in humans, particularly for dissolving thrombus. The catheter may also incorporate anti-thrombolytic drug treatments as an adjunct therapy and it may be operated in conjunction with ultrasonic detection equipment for imaging and feedback control. 7 figs.

  16. Broadband optoacoustic characterization of cMUT and PZT transducer directivity in receive mode

    Science.gov (United States)

    Rebling, Johannes; Warshavski, Omri; Meynier, Cyril; Razansky, Daniel

    2017-03-01

    Optoacoustic imaging is a rapidly developing area of biomedical imaging due its combination of rich optical contrast and ultrasound depth penetration. Just like conventional pulse-echo ultrasound imaging, optoacoustic tomography relies on the use of ultrasound detector arrays with a large number of elements. The precise knowledge of the transducer's sensitivity is crucial for the prediction of its performance for a given imaging task. Sensitivity characteristics such as the central frequency and bandwidth are routinely characterized. However, this characterization is typically performed solely under normal incidence since the measurement of the angle and frequency depended sensitivity (directivity) is difficult and time consuming with existing ultrasound characterization methods. We present a simple and fast characterization method for broadband directivity measurements of the angular transducer sensitivity based on the optoacoustic effect. The method utilizes a thin absorbing suture in order to generate omnidirectional and broadband optoacoustic signals, which are calibrated using a needle hydrophone. We applied this method to characterize and compare the directivity of a conventional piezoelectric (PZT) transducer to the directivity of a capacitive micromachined ultrasonic (cMUT) transducer. Both technologies showed a similar broadband response at normal incidence and the PZT transducer displayed a more than two times larger signal to noise ratio at normal incidence. However, the cMUT transducer's sensitivity was significantly less angle-depended and outperformed the PZT's sensitivity for angles larger than 20°.

  17. A novel two-axis micromechanical scanning transducer for handheld 3D ultrasound and photoacoustic imaging

    Science.gov (United States)

    Huang, Chih-Hsien; Zou, Jun

    2016-03-01

    This paper reports the development of a new two-axis micromechanical scanning transducer for handheld 3D ultrasound imaging. It consists of a miniaturized single-element ultrasound transducer driven by a unique 2-axis liquid-immersible electromagnetic microactuator. With a mechanical scanning frequency of 19.532 Hz and an ultrasound pulse repetition rate of 5 kHz, the scanning transducer was scanned along 60 concentric paths with 256 detection points on each to simulate a physical 2D ultrasound transducer array of 60 × 256 elements. Using the scanning transducer, 3D pulse-echo ultrasound imaging of two silicon discs immersed in water as the imaging target was successfully conducted. The lateral resolution of the 3D ultrasound image was further improved with the synthetic aperture focusing technique (SAFT). The new two-axis micromechanical scanning transducer doesn't require complex and expensive multi-channel data acquisition (DAQ) electronics. Therefore, it could provide a new approach to achieve compact and low-cost 3D ultrasound and photoacoustic imaging systems, especially for handheld operations.

  18. Using Portable Transducers to Measure Tremor Severity

    Directory of Open Access Journals (Sweden)

    Rodger Elble

    2016-05-01

    Full Text Available Background: Portable motion transducers, suitable for measuring tremor, are now available at a reasonable cost. The use of these transducers requires knowledge of their limitations and data analysis. The purpose of this review is to provide a practical overview and example software for using portable motion transducers in the quantification of tremor. Methods: Medline was searched via PubMed.gov in December 2015 using the Boolean expression “tremor AND (accelerometer OR accelerometry OR gyroscope OR inertial measurement unit OR digitizing tablet OR transducer.” Abstracts of 419 papers dating back to 1964 were reviewed for relevant portable transducers and methods of tremor analysis, and 105 papers written in English were reviewed in detail. Results: Accelerometers, gyroscopes, and digitizing tablets are used most commonly, but few are sold for the purpose of measuring tremor. Consequently, most software for tremor analysis is developed by the user. Wearable transducers are capable of recording tremor continuously, in the absence of a clinician. Tremor amplitude, frequency, and occurrence (percentage of time with tremor can be computed. Tremor amplitude and occurrence correlate strongly with clinical ratings of tremor severity. Discussion: Transducers provide measurements of tremor amplitude that are objective, precise, and valid, but the precision and accuracy of transducers are mitigated by natural variability in tremor amplitude. This variability is so great that the minimum detectable change in amplitude, exceeding random variability, is comparable for scales and transducers. Research is needed to determine the feasibility of detecting smaller change using averaged data from continuous long-term recordings with wearable transducers.

  19. Fabrication of Linear Array and Top-Orthogonal-to-Bottom Electrode CMUT Arrays With a Sacrificial Release Process.

    Science.gov (United States)

    Greenlay, Benjamin A; Zemp, Roger J

    2017-01-01

    The microfabrication processes for sacrificial-release-based capacitive micromachined ultrasound transducer arrays are provided with an emphasis on top-orthogonal-to-bottom electrode 2-D arrays. These arrays have significant promise for high-quality 3-D imaging with reduced wiring complexity compared with fully wired arrays. The protocols and best practices are outlined in significant detail along with design considerations and notes of caution for pitfalls and factors impacting yield.

  20. Fabrication of Linear Array and Top-Orthogonal-to-Bottom Electrode (TOBE) CMUT Arrays with a Sacrificial Release Process.

    Science.gov (United States)

    Greenlay, Benjamin; Zemp, Roger

    2016-10-24

    The microfabrication processes for sacrificial-release based capacitive micromachined ultrasound transducer (CMUT) arrays are provided with an emphasis on top-orthogonal-to-bottom electrode (TOBE) 2D arrays. These arrays have significant promise for high-quality 3D imaging with reduced wiring complexity compared to fully-wired arrays. The protocols and best practices are outlined in significant detail along with design considerations and notes of caution for pitfalls and factors impacting yield.

  1. Efficient array design for sonotherapy

    International Nuclear Information System (INIS)

    Stephens, Douglas N; Kruse, Dustin E; Ferrara, Katherine W; Ergun, Arif S; Barnes, Stephen; Lu, X Ming

    2008-01-01

    New linear multi-row, multi-frequency arrays have been designed, constructed and tested as fully operational ultrasound probes to produce confocal imaging and therapeutic acoustic intensities with a standard commercial ultrasound imaging system. The triple-array probes and imaging system produce high quality B-mode images with a center row imaging array at 5.3 MHz and sufficient acoustic power with dual therapeutic arrays to produce mild hyperthermia at 1.54 MHz. The therapeutic array pair in the first probe design (termed G3) utilizes a high bandwidth and peak pressure, suitable for mechanical therapies. The second multi-array design (termed G4) has a redesigned therapeutic array pair which is optimized for a high time-averaged power output suitable for mild hyperthermia applications. The 'thermal therapy' design produces more than 4 W of acoustic power from the low-frequency arrays with only a 10.5 deg. C internal rise in temperature after 100 s of continuous use with an unmodified conventional imaging system or substantially longer operation at lower acoustic power. The low-frequency arrays in both probe designs were examined and contrasted for real power transfer efficiency with a KLM model which includes all lossy contributions in the power delivery path from system transmitters to the tissue load. Laboratory verification was successfully performed for the KLM-derived estimates of transducer parallel model acoustic resistance and dissipation resistance, which are the critical design factors for acoustic power output and undesired internal heating, respectively

  2. Radiation impedance of collapsed capacitive micromachined ultrasonic transducers.

    Science.gov (United States)

    Ozgurluk, Alper; Atalar, Abdullah; Köymen, Hayrettin; Olçum, Selim

    2012-06-01

    The radiation impedance of a capacitive micromachined ultrasonic transducer (CMUT) array is a critical parameter to achieve high performance. In this paper, we present a calculation of the radiation impedance of collapsed, clamped, circular CMUTs both analytically and using finite element method (FEM) simulations. First, we model the radiation impedance of a single collapsed CMUT cell analytically by expressing its velocity profile as a linear combination of special functions for which the generated pressures are known. For an array of collapsed CMUT cells, the mutual impedance between the cells is also taken into account. The radiation impedances for arrays of 7, 19, 37, and 61 circular collapsed CMUT cells for different contact radii are calculated both analytically and by FEM simulations. The radiation resistance of an array reaches a plateau and maintains this level for a wide frequency range. The variation of radiation reactance with respect to frequency indicates an inductance-like behavior in the same frequency range. We find that the peak radiation resistance value is reached at higher kd values in the collapsed case as compared with the uncollapsed case, where k is the wavenumber and d is the center-to-center distance between two neighboring CMUT cells.

  3. On the nonlinear interfacial instability of rotating core-annular flow

    Science.gov (United States)

    Coward, Aidrian V.; Hall, Philip

    1993-01-01

    The interfacial stability of rotating core-annular flows is investigated. The linear and nonlinear effects are considered for the case when the annular region is very thin. Both asymptotic and numerical methods are used to solve the flow in the core and film regions which are coupled by a difference in viscosity and density. The long-term behavior of the fluid-fluid interface is determined by deriving its nonlinear evolution in the form of a modified Kuramoto-Sivashinsky equation. We obtain a generalization of this equation to three dimensions. The flows considered are applicable to a wide array of physical problems where liquid films are used to lubricate higher or lower viscosity core fluids, for which a concentric arrangement is desired. Linearized solutions show that the effects of density and viscosity stratification are crucial to the stability of the interface. Rotation generally destabilizes non-axisymmetric disturbances to the interface, whereas the centripetal forces tend to stabilize flows in which the film contains the heavier fluid. Nonlinear affects allow finite amplitude helically travelling waves to exist when the fluids have different viscosities.

  4. Azimuthally spinning wave modes and heat release in an annular combustor

    Science.gov (United States)

    Nygard, Hakon; Mazur, Marek; Dawson, James R.; Worth, Nicholas A.

    2017-11-01

    In order to reduce NOx emissions from aeroengines and stationary gas turbines the fuel-air mixture can be made leaner, at the risk of introducing potentially damaging thermo-acoustic instabilities. At present this phenomenon is not understood well enough to eliminate these instabilities at the design stage. Recently, the presence of different azimuthal modes in annular combustors has been demonstrated both experimentally and numerically. These naturally occurring instabilities in annular geometry have been observed to constantly switch between spinning and standing modes, making it more difficult to analyse the flame structure and dynamics. Very recently this issue was partially addressed using novel acoustic forcing to generate a standing mode. In the present study this concept has been developed further by creating an azimuthal array of loud speakers, which for the first time permits predominantly spinning modes to be set up inside the combustion chamber. The use of pressure and high speed OH* measurements enables the study of the flame dynamics and heat release rate oscillations of the combustor, which will be reported in the current paper. The ability to precisely control the azimuthal mode of oscillation greatly enhances our further understanding of the phenomenon. This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant Agreement No 677931 TAIAC).

  5. Energy and exergy analysis of an annular thermoelectric cooler

    International Nuclear Information System (INIS)

    Manikandan, S.; Kaushik, S.C.

    2015-01-01

    Highlights: • Exergy analysis in the annular thermoelectric cooler (ATEC) system is proposed. • Analytical expressions for the cooling power, exergy efficiency of an ATEC is derived. • The effects of S r and θ in Q c and exergy efficiency of an ATEC is studied. - Abstract: In this paper the concept of annular thermoelectric cooler (ATEC) has been introduced. An exoreversible thermodynamic model of the annular thermoelectric cooler considering Thomson effect in conjunction with Peltier, Joule and Fourier heat conduction has been investigated using exergy analysis. New expressions for optimum current at the maximum energy/exergy efficiency, maximum cooling power conditions and dimensionless irreversibilities in the ATEC are derived. The modified expression for figure of merit of a thermoelectric cooler considering the Thomson effect has also been obtained. The results show that the cooling power, energy and exergy efficiency of the ATEC is lower than the flat plate thermoelectric cooler. The effects of annular shape parameter (S r = r 2 /r 1 ), dimensionless temperature ratio (θ = T h /T c ) and the electrical contact resistances on cooling power, energy/exergy efficiency of an ATEC have been studied. It has also been proved that because of the influence of Thomson effect, the cooling power and energy/exergy efficiency of the ATEC is increased. This study will help in the designing of the actual annular thermoelectric cooling systems.

  6. Experimental verification of focusability of coherent annular laser beams

    Science.gov (United States)

    Astadjov, Dimo N.; Prakash, Om

    2013-03-01

    Experiments of focusing coherent laser beams being diffracted on annular aperture are carried out in order to verify issues of a two-dimensional Fast Fourier Transform simulation of coherent pure (dark) annular flat beams done and published before. The beam pattern at focal plane (aka the far-field pattern) is a prominent central peak and faint concentrical rings around it. In the course of simulation we calculate the fraction of the central peak power to the whole power of beam that gives a notion of power spread within the focal spot. This fraction is a function of beam annularity i.e. `inside diameter /outside diameter' ratio. The experimentally-measured dependence of the central peak power to the whole power of beam versus the annularity of pure annular laser beams was the major target of the report. The purpose was to verify experimentally the issues of our earlier simulation. We found that from the five experimental points four of them are within 16% error as to the simulated dependence which is tolerable in such a measurement.

  7. Far-field Diffraction Properties of Annular Walsh Filters

    Directory of Open Access Journals (Sweden)

    Pubali Mukherjee

    2013-01-01

    Full Text Available Annular Walsh filters are derived from the rotationally symmetric annular Walsh functions which form a complete set of orthogonal functions that take on values either +1 or −1 over the domain specified by the inner and outer radii of the annulus. The value of any annular Walsh function is taken as zero from the centre of the circular aperture to the inner radius of the annulus. The three values 0, +1, and −1 in an annular Walsh function can be realized in a corresponding annular Walsh filter by using transmission values of zero amplitude (i.e., an obscuration, unity amplitude and zero phase, and unity amplitude and phase, respectively. Not only the order of the Walsh filter but also the size of the inner radius of the annulus provides an additional degree of freedom in tailoring of point spread function by using these filters for pupil plane filtering in imaging systems. In this report, we present the far-field amplitude characteristics of some of these filters to underscore their potential for effective use in several demanding applications like high-resolution microscopy, optical data storage, microlithography, optical encryption, and optical micromanipulation.

  8. Magnetic arrays

    Science.gov (United States)

    Trumper, D.L.; Kim, W.; Williams, M.E.

    1997-05-20

    Electromagnet arrays are disclosed which can provide selected field patterns in either two or three dimensions, and in particular, which can provide single-sided field patterns in two or three dimensions. These features are achieved by providing arrays which have current densities that vary in the windings both parallel to the array and in the direction of array thickness. 12 figs.

  9. Magnetic arrays

    Energy Technology Data Exchange (ETDEWEB)

    Trumper, David L. (Plaistow, NH); Kim, Won-jong (Cambridge, MA); Williams, Mark E. (Pelham, NH)

    1997-05-20

    Electromagnet arrays which can provide selected field patterns in either two or three dimensions, and in particular, which can provide single-sided field patterns in two or three dimensions. These features are achieved by providing arrays which have current densities that vary in the windings both parallel to the array and in the direction of array thickness.

  10. Phased-array vector velocity estimation using transverse oscillations

    DEFF Research Database (Denmark)

    Pihl, Michael Johannes; Marcher, Jønne; Jensen, Jørgen Arendt

    2012-01-01

    A method for estimating the 2-D vector velocity of blood using a phased-array transducer is presented. The approach is based on the transverse oscillation (TO) method. The purposes of this work are to expand the TO method to a phased-array geometry and to broaden the potential clinical applicabil......A method for estimating the 2-D vector velocity of blood using a phased-array transducer is presented. The approach is based on the transverse oscillation (TO) method. The purposes of this work are to expand the TO method to a phased-array geometry and to broaden the potential clinical...... of the TO method using a phased-array transducer for vector velocity estimation is evaluated through simulation and flow-rig measurements are acquired using an experimental scanner. The vast number of calculations needed to perform flow simulations makes the optimization of the TO fields a cumbersome process......, but with a poorer performance compared with a 128-element transducer. The simulation and experimental results demonstrate that the TO method is suitable for use in conjunction with a phased-array transducer, and that 2-D vector velocity estimation is possible down to a depth of 15 cm....

  11. Localized Bioconvection Patterns and Their Initial State Dependency in Euglena gracilis Suspensions in an Annular Container

    Science.gov (United States)

    Shoji, Erika; Nishimori, Hiraku; Awazu, Akinori; Izumi, Shunsuke; Iima, Makoto

    2014-04-01

    Localized patterns of bioconvection in Euglena gracilis suspensions were experimentally analyzed in an annular container. Near the critical mean density of convection, we succeeded in isolating two basic types of localized convection patterns. One was an almost stationary pattern consisting of two convection cells centered by an isolated high-density region of the microorganism where a downflow was generated, which we call a "bioconvection unit". The other was a traveling wave pattern consisting of an array of moving high-density waves bounded in a certain area. The effect of the mean density of E. gracilis on the emergence of the localized convection pattern was also examined. Near the critical mean density, we found that the emergence probability of the localized convection pattern depends on the initial state, i.e., whether E. gracilis has a uniform or localized distribution, which suggests that the system is bistable. Such bistability is often accompanied by localized structures in spatially extended dissipative systems.

  12. Vibration Analysis of Annular Sector Plates under Different Boundary Conditions

    Directory of Open Access Journals (Sweden)

    Dongyan Shi

    2014-01-01

    Full Text Available An analytical framework is developed for the vibration analysis of annular sector plates with general elastic restraints along each edge of plates. Regardless of boundary conditions, the displacement solution is invariably expressed as a new form of trigonometric expansion with accelerated convergence. The expansion coefficients are treated as the generalized coordinates and determined using the Rayleigh-Ritz technique. This work allows a capability of modeling annular sector plates under a variety of boundary conditions and changing the boundary conditions as easily as modifying the material properties or dimensions of the plates. Of equal importance, the proposed approach is universally applicable to annular sector plates of any inclusion angles up to 2π. The reliability and accuracy of the current method are adequately validated through numerical examples.

  13. Experiments on soliton motion in annular Josephson junctions

    DEFF Research Database (Denmark)

    Davidson, A.; Dueholm, B.; Pedersen, Niels Falsig

    1986-01-01

    We report here the results of an extensive experimental investigation of soliton dynamics in Josephson junctions of different annular geometries. The annular geometry is unique in that it allows for the study of undisturbed soliton motion as well as soliton–antisoliton collisons, since...... there are no boundary effects. We have successfully trapped a single soliton in an annular junction and found good agreement with perturbation theory at low soliton velocity, and evidence of departure from perturbation theory at higher velocity. We also discuss the observation of fine structure on the I-V curve...... for a single trapped soliton, and evidence linking the stability of the soliton to surface damping. Journal of Applied Physics is copyrighted by The American Institute of Physics....

  14. Frequency Steered Acoustic Transducer, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase II project is to fabricate, characterize, and verify performance of a new type of frequency steered acoustic transducer...

  15. Frequency Steered Acoustic Transducer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project is to develop, fabricate, and characterize a novel frequency steered acoustic transducer (FSAT) for the...

  16. Activity patterns of cultured neural networks on micro electrode arrays

    NARCIS (Netherlands)

    Rutten, Wim; van Pelt, J.

    2001-01-01

    A hybrid neuro-electronic interface is a cell-cultured micro electrode array, acting as a neural information transducer for stimulation and/or recording of neural activity in the brain or the spinal cord (ventral motor region or dorsal sensory region). It consists of an array of micro electrodes on

  17. Ultrasonic transducer for extreme temperature environments

    Science.gov (United States)

    Light, Glenn M.; Cervantes, Richard A.; Alcazar, David G.

    1993-03-23

    An ultrasonic piezoelectric transducer that is operable in very high and very low temperatures. The transducer has a dual housing structure that isolates the expansion and contraction of the piezoelectric element from the expansion and contraction of the housing. Also, the internal components are made from materials having similar coefficients of expansion so that they do not interfere with the motion of the piezoelectric element.

  18. Supra-annular mitral valve replacement in children.

    Science.gov (United States)

    Kanter, Kirk R; Kogon, Brian E; Kirshbom, Paul M

    2011-12-01

    Despite improved mitral repair techniques, some children need mitral valve replacement (MVR). Due to small annulus size, supra-annular MVR is useful. From 2003 to 2010, 15 children had 23 supra-annular MVRs. At first supra-annular MVR, median age was 6.5 months (28 days to 47 months); median weight was 5.4 kg (3.3-11.8 kg). Twelve (80%) had prior operations, 8 (53%) had previous mitral repair. Eight had congenital mitral anomalies (4 with Shone's), 5 had atrioventricular septal defects, 1 had endocarditis, and 1 had a repaired anomalous left coronary artery. All primary MVRs used mechanical valves (≤ 17 mm in 9 patients). There was one early death (93% survival) in an 11-month-old with congenital pulmonary vein stenosis. One intraoperative conversion from annular to supra-annular MVR developed heart block. Three pacemakers were implanted for supraventricular rhythm disturbances. Three children had valve thrombosis early postoperatively treated medically. On follow-up of 4.3 ± 2.8 years, 8 had reoperation including redo MVR in 6 for pannus formation or thrombus (1 had three redo MVRs). At redo, a larger valve was used in 5 and a bioprosthetic valve in 4 patients. There was one late death after third redo MVR with pulmonary vein stenosis relief (overall survival 87%). Supra-annular MVR is useful for children with a small annulus. Operative survival is good with infrequent heart block. Complications are common, including redo MVR and need for left ventricular outflow tract obstruction relief. Pulmonary vein stenosis is a marker for poor outcome; all patients without pulmonary vein stenosis survive long term. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Ultrasound transducer disinfection in emergency medicine practice

    Directory of Open Access Journals (Sweden)

    Riley Hoyer

    2016-04-01

    Full Text Available Abstract Background External ultrasound transducer disinfection is common practice in medicine. Unfortunately, clinically significant organisms, such as methicillin-resistant Staphylococcus aureus (MRSA, Pseudomonas aeruginosa, and Klebsiella pneumonia spread throughout healthcare facilities via direct contact despite disinfection protocols. Ultrasound transducers and coupling gel provide potential vectors for pathogen transmission, especially in immunocompromised and high-risk patient populations. Our objective was to conduct a survey to investigate the variety of cleaning solutions or sanitary wipes used and evaluate current standard practice for transducer disinfection across emergency medicine training programs in the United States. Findings Eighty-three academic emergency medicine programs participated in this study. Eighty-seven percent (95 % CI 80–94 % of responding programs do not have a mandated protocol or standard contact time for transducer disinfection. Ninety percent (95 % CI 84–96 % of institutions use disinfectant solution or disinfectant wipes, as the standard of practice, to cleanse ultrasound transducers after every use. Conclusions Currently, there is a great deal of variability with regard to non-endocavitary transducer disinfection protocols that seems to stem from the vast number of disinfectant products and ultrasound manufacturer disparate recommendations. In order to mitigate risk to patients and reduce health care costs linked to nosocomial infections; healthcare providers, ultrasound companies, and disinfectant manufacturers must develop a universal use disinfectant and a standard protocol for ultrasound device disinfection for noncritical device disinfection in the emergency department.

  20. Ultrasound transducer disinfection in emergency medicine practice.

    Science.gov (United States)

    Hoyer, Riley; Adhikari, Srikar; Amini, Richard

    2016-01-01

    External ultrasound transducer disinfection is common practice in medicine. Unfortunately, clinically significant organisms, such as methicillin-resistant Staphylococcus aureus (MRSA), Pseudomonas aeruginosa, and Klebsiella pneumonia spread throughout healthcare facilities via direct contact despite disinfection protocols. Ultrasound transducers and coupling gel provide potential vectors for pathogen transmission, especially in immunocompromised and high-risk patient populations. Our objective was to conduct a survey to investigate the variety of cleaning solutions or sanitary wipes used and evaluate current standard practice for transducer disinfection across emergency medicine training programs in the United States. Eighty-three academic emergency medicine programs participated in this study. Eighty-seven percent (95 % CI 80-94 %) of responding programs do not have a mandated protocol or standard contact time for transducer disinfection. Ninety percent (95 % CI 84-96 %) of institutions use disinfectant solution or disinfectant wipes, as the standard of practice, to cleanse ultrasound transducers after every use. Currently, there is a great deal of variability with regard to non-endocavitary transducer disinfection protocols that seems to stem from the vast number of disinfectant products and ultrasound manufacturer disparate recommendations. In order to mitigate risk to patients and reduce health care costs linked to nosocomial infections; healthcare providers, ultrasound companies, and disinfectant manufacturers must develop a universal use disinfectant and a standard protocol for ultrasound device disinfection for noncritical device disinfection in the emergency department.

  1. Handbook of force transducers. Principles and components

    Energy Technology Data Exchange (ETDEWEB)

    Stefanescu, Dan Mihai [Romanian Measurement Society, Bucharest (Romania)

    2011-07-01

    Part I introduces the basic ''Principles and Methods of Force Measurement'' according to a classification into a dozen of force transducers types: resistive, inductive, capacitive, piezoelectric, electromagnetic, electrodynamic, magnetoelastic, galvanomagnetic (Hall-effect), vibrating wires, (micro)resonators, acoustic and gyroscopic. Two special chapters refer to force balance techniques and to combined methods in force measurement. Part II discusses the ''(Strain Gauge) Force Transducers Components'', evolving from the classical force transducer to the digital / intelligent one, with the incorporation of three subsystems (sensors, electromechanics and informatics). The elastic element (EE) is the ''heart'' of the force transducer and basically determines its performance. A 12-type elastic element classification is proposed (stretched / compressed column or tube, bending beam, bending and/or torsion shaft, middle bent bar with fixed ends, shear beam, bending ring, yoke or frame, diaphragm, axial-stressed torus, axisymmetrical and voluminous EE), with emphasis on the optimum location of the strain gauges. The main properties of the associated Wheatstone bridge, best suited for the parametrical transducers, are examined, together with the appropriate electronic circuits for SGFTs. The handbook fills a gap in the field of Force Measurement, both experts and newcomers, no matter of their particular interest, finding a lot of useful and valuable subjects in the area of Force Transducers; in fact, it is the first specialized monograph in this inter- and multidisciplinary field. (orig.)

  2. A void fraction model for annular two-phase flow

    Energy Technology Data Exchange (ETDEWEB)

    Tandon, T.N.; Gupta, C.P.; Varma, H.K.

    1985-01-01

    An analytical model has been developed for predicting void fraction in two-phase annular flow. In the analysis, the Lockhart-Martinelli method has been used to calculate two-phase frictional pressure drop and von Karman's universal velocity profile is used to represent the velocity distribution in the annular liquid film. Void fractions predicted by the proposed model are generally in good agreement with a available experimental data. This model appears to be as good as Smith's correlation and better than the Wallis and Zivi correlations for computing void fraction.

  3. Mitral-aortic annular enlargement: modification of Manouguian's technique

    Directory of Open Access Journals (Sweden)

    Costa Mario Gesteira

    2002-01-01

    Full Text Available We hereby present a technical modification for mitral-aortic annular enlargement. The mitral valve is replaced through the retro-septal approach, avoiding patches for left atrial roof closure. We report a mitral-aortic valve replacement in a patient whose original annuli would preclude adequate prostheses. The simultaneous annular enlargement may be necessary for avoiding patient-prosthesis mismatch and for reconstructing destroyed mitral and aortic annuli. The technique may minimize the risk of bleeding and of paravalvular leakage, using an approach well known to cardiac surgeons.

  4. Wall pressure measurements of flooding in vertical countercurrent annular air–water flow

    Energy Technology Data Exchange (ETDEWEB)

    Choutapalli, I., Vierow, K.

    2010-01-01

    An experimental study of flooding in countercurrent air-water annular flow in a large diameter vertical tube using wall pressure measurements is described in this paper. Axial pressure profiles along the length of the test section were measured up to and after flooding using fast response pressure transducers for three representative liquid flow rates representing a wide range of liquid Reynolds numbers (ReL = 4Γ/μ; Γ is the liquid mass flow rate per unit perimeter; μ is the dynamic viscosity) from 3341 to 19,048. The results show that flooding in large diameter tubes cannot be initiated near the air outlet and is only initiated near the air inlet. Fourier analysis of the wall pressure measurements shows that up to the point of flooding, there is no dominant wave frequency but rather a band of frequencies encompassing both the low frequency and the broad band that are responsible for flooding. The data indicates that flooding in large diameter vertical tubes may be caused by the constructive superposition of a plurality of waves rather than the action of a single large-amplitude wave.

  5. 2D Analytical Model for the Directivity Prediction of Ultrasonic Contact Type Transducers in the Generation of Guided Waves.

    Science.gov (United States)

    Tiwari, Kumar Anubhav; Raisutis, Renaldas; Mazeika, Liudas; Samaitis, Vykintas

    2018-03-26

    In this paper, a novel 2D analytical model based on the Huygens's principle of wave propagation is proposed in order to predict the directivity patterns of contact type ultrasonic transducers in the generation of guided waves (GWs). The developed model is able to estimate the directivity patterns at any distance, at any excitation frequency and for any configuration and shape of the transducers with prior information of phase dispersive characteristics of the guided wave modes and the behavior of transducer. This, in turn, facilitates to choose the appropriate transducer or arrays of transducers, suitable guided wave modes and excitation frequency for the nondestructive testing (NDT) and structural health monitoring (SHM) applications. The model is demonstrated for P1-type macro-fiber composite (MFC) transducer glued on a 2 mm thick aluminum (Al) alloy plate. The directivity patterns of MFC transducer in the generation of fundamental guided Lamb modes (the S0 and A0) and shear horizontal mode (the SH0) are successfully obtained at 80 kHz, 5-period excitation signal. The results are verified using 3D finite element (FE) modelling and experimental investigation. The results obtained using the proposed model shows the good agreement with those obtained using numerical simulations and experimental analysis. The calculation time using the analytical model was significantly shorter as compared to the time spent in experimental analysis and FE numerical modelling.

  6. 2D Analytical Model for the Directivity Prediction of Ultrasonic Contact Type Transducers in the Generation of Guided Waves

    Directory of Open Access Journals (Sweden)

    Kumar Anubhav Tiwari

    2018-03-01

    Full Text Available In this paper, a novel 2D analytical model based on the Huygens’s principle of wave propagation is proposed in order to predict the directivity patterns of contact type ultrasonic transducers in the generation of guided waves (GWs. The developed model is able to estimate the directivity patterns at any distance, at any excitation frequency and for any configuration and shape of the transducers with prior information of phase dispersive characteristics of the guided wave modes and the behavior of transducer. This, in turn, facilitates to choose the appropriate transducer or arrays of transducers, suitable guided wave modes and excitation frequency for the nondestructive testing (NDT and structural health monitoring (SHM applications. The model is demonstrated for P1-type macro-fiber composite (MFC transducer glued on a 2 mm thick aluminum (Al alloy plate. The directivity patterns of MFC transducer in the generation of fundamental guided Lamb modes (the S0 and A0 and shear horizontal mode (the SH0 are successfully obtained at 80 kHz, 5-period excitation signal. The results are verified using 3D finite element (FE modelling and experimental investigation. The results obtained using the proposed model shows the good agreement with those obtained using numerical simulations and experimental analysis. The calculation time using the analytical model was significantly shorter as compared to the time spent in experimental analysis and FE numerical modelling.

  7. Annular fuel element for high-temperature reactors

    International Nuclear Information System (INIS)

    Bujas, R.

    1975-01-01

    A description is given of a compacted fuel element of annular shape which is enclosed in a graphite casing constituted by an inner tube and an outer tube. The inner tube is formed of graphite having a lower coefficient of shrinkage than the graphite of the outer tube under irradiation and is of smaller thickness than the outer tube

  8. Free asymmetric transverse vibration of polar orthotropic annular ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    Houmat A 2001 A sector Fourier p-element applied to free vibration analysis of sectorial plates. J. Sound Vibr. 243: 269–282. Irie T, Yamada G, Ito F 1979 Free vibration of polar orthotropic sector plates. J. Sound Vibr 67: 89–100. Irie T, Tanaka K, Yamada G 1988 Free vibration of a cantilever annular sector plate with curved ...

  9. Magnetic fluid based squeeze film between porous annular curved ...

    Indian Academy of Sciences (India)

    lower plate, considering a magnetic fluid lubricant in the presence of an external magnetic field oblique to the plates. Expressions were obtained for ... Keywords. Magnetic fluid; lubrication; annular curved plates. PACS No. 81.40.Pq. 1. Introduction ... is backed by a solid wall. The film thickness h is taken as h =h0 exp(-Br2); ...

  10. Design and simulation of double annular illumination mode for microlithography

    Science.gov (United States)

    Song, Qiang; Zhu, Jing; Yang, Baoxi; Liu, Lei; Wang, Jun; Huang, Huijie

    2013-08-01

    Methods of generating various illumination patterns remain as an attractive and important micro-optics research area for the development of resolution enhancement in advanced lithography system. In the current illumination system of lithography machine, off-axis illumination is widely used as an effective approach to enhance the resolution and increase the depth of focus (DOF). This paper proposes a novel illumination mode generation unit, which transform conventional mode to double annular shaped radial polarized (DARP) mode for improving the resolution of micro-lithography. Through LightToolsTM software simulation, double annular shaped mode is obtained from the proposed generation unit. The mathematical expressions of the radius variation of inner and outer rings are deduced. The impacts of conventional and dual concentric annular illumination pattern on critical dimension uniformity were simulated on an isolated line, square hole and corner. Lithography performance was compared between DARP illumination mode and corresponding single annular modes under critical dimension of 45nm. As a result, DARP illumination mode can improve the uniformity of aerial image at 45nm node through pitch varied in 300-500 nm to a certain extent.

  11. Quench-induced trapping of magnetic flux in annular

    DEFF Research Database (Denmark)

    Aaroe, M.; Monaco, R.; Rivers, R.

    2008-01-01

    The aim of the project is to investigate spontaneous symmetry breaking in non-adiabatic phase transitions (Kibble-Zurek processes). A long and narrow annular Josephson tunnel junction is subjected to repeated thermal quenches through the normal-superconducting transition. The quench rate is varied...

  12. Localized granuloma annulare and autoimmune thyroiditis in a ...

    African Journals Online (AJOL)

    The association of granuloma annulare (GA) and autoimmune thyroiditis has been documented in the literature in 13 previous cases. However, the pathogenesis of GA remains obscure. Possible pathogenetic factors suggested include: humoral and delayed type hypersensitivity, vascular damage, metabolic disorder, or, ...

  13. Adjoint Optimisation of the Turbulent Flow in an Annular Diffuser

    DEFF Research Database (Denmark)

    Gotfredsen, Erik; Agular Knudsen, Christian; Kunoy, Jens Dahl

    2017-01-01

    In the present study, a numerical optimisation of guide vanes in an annular diffuser, is performed. The optimisation is preformed for the purpose of improving the following two parameters simultaneously; the first parameter is the uniformity perpen-dicular to the flow direction, a 1/3 diameter do...

  14. Effect of annular secondary conductor in a linear electromagnetic ...

    Indian Academy of Sciences (India)

    with a solid cylinder. Force density variation with supply frequency and current are also reported. Numerical simulations using finite element model are ... Linear electromagnetic stirrer; finite element analysis; and annular ring. ... flows through the coil of the primary and generates an eddy current in the secondary conductor.

  15. Squeeze Film Behaviour in Rotating Porous Annular Discs ...

    African Journals Online (AJOL)

    The squeeze film behaviour between rotating annular discs, when the upper disc with a porous facing approached the parallel lower disc, was theoretically analysed. The lubricant was a magnetic fluid and the external magnetic field was oblique to the lower disc. Expressions were obtained for pressure, load capacity and ...

  16. Palmar annular ligament desmotomy in horses with the Arthrex ...

    African Journals Online (AJOL)

    Ibrahim Eldaghayes

    2018-01-25

    Jan 25, 2018 ... Published: 07/02/2018. Palmar annular ligament desmotomy in horses with the Arthrex-Centerline™ ... Ten horse distal front limbs from horses free of PAL disease were prepared for tenoscopy of the digital flexor tendon sheath .... operative field, a better diagnosis and a reduction in both the surgical wound.

  17. Fully integrated monolithic opoelectronic transducer for real.time protein and DNA detection

    DEFF Research Database (Denmark)

    Misiakos, Konstatinos; S. Petrou, Panagiota; E. Kakabakos, Sotirios

    2010-01-01

    The development and testing of a portable bioanalytical device which was capable for real-time monitoring of binding assays was demonstrated. The device was based on arrays of nine optoelectronic transducers monolithically integrated on silicon chips. The optocouplers consisted of nine silicon...... by exploiting wavelength filtering on photonic crystal engineered waveguides. The proposed miniaturized sensing device with proper packaging and accompanied by a portable instrument can find wide application as a platform for reliable and cost effective point-of-care diagnosis....

  18. High Temperature, High Power Piezoelectric Composite Transducers

    Directory of Open Access Journals (Sweden)

    Hyeong Jae Lee

    2014-08-01

    Full Text Available Piezoelectric composites are a class of functional materials consisting of piezoelectric active materials and non-piezoelectric passive polymers, mechanically attached together to form different connectivities. These composites have several advantages compared to conventional piezoelectric ceramics and polymers, including improved electromechanical properties, mechanical flexibility and the ability to tailor properties by using several different connectivity patterns. These advantages have led to the improvement of overall transducer performance, such as transducer sensitivity and bandwidth, resulting in rapid implementation of piezoelectric composites in medical imaging ultrasounds and other acoustic transducers. Recently, new piezoelectric composite transducers have been developed with optimized composite components that have improved thermal stability and mechanical quality factors, making them promising candidates for high temperature, high power transducer applications, such as therapeutic ultrasound, high power ultrasonic wirebonding, high temperature non-destructive testing, and downhole energy harvesting. This paper will present recent developments of piezoelectric composite technology for high temperature and high power applications. The concerns and limitations of using piezoelectric composites will also be discussed, and the expected future research directions will be outlined.

  19. High Temperature, High Power Piezoelectric Composite Transducers

    Science.gov (United States)

    Lee, Hyeong Jae; Zhang, Shujun; Bar-Cohen, Yoseph; Sherrit, StewarT.

    2014-01-01

    Piezoelectric composites are a class of functional materials consisting of piezoelectric active materials and non-piezoelectric passive polymers, mechanically attached together to form different connectivities. These composites have several advantages compared to conventional piezoelectric ceramics and polymers, including improved electromechanical properties, mechanical flexibility and the ability to tailor properties by using several different connectivity patterns. These advantages have led to the improvement of overall transducer performance, such as transducer sensitivity and bandwidth, resulting in rapid implementation of piezoelectric composites in medical imaging ultrasounds and other acoustic transducers. Recently, new piezoelectric composite transducers have been developed with optimized composite components that have improved thermal stability and mechanical quality factors, making them promising candidates for high temperature, high power transducer applications, such as therapeutic ultrasound, high power ultrasonic wirebonding, high temperature non-destructive testing, and downhole energy harvesting. This paper will present recent developments of piezoelectric composite technology for high temperature and high power applications. The concerns and limitations of using piezoelectric composites will also be discussed, and the expected future research directions will be outlined. PMID:25111242

  20. High temperature, high power piezoelectric composite transducers.

    Science.gov (United States)

    Lee, Hyeong Jae; Zhang, Shujun; Bar-Cohen, Yoseph; Sherrit, Stewart

    2014-08-08

    Piezoelectric composites are a class of functional materials consisting of piezoelectric active materials and non-piezoelectric passive polymers, mechanically attached together to form different connectivities. These composites have several advantages compared to conventional piezoelectric ceramics and polymers, including improved electromechanical properties, mechanical flexibility and the ability to tailor properties by using several different connectivity patterns. These advantages have led to the improvement of overall transducer performance, such as transducer sensitivity and bandwidth, resulting in rapid implementation of piezoelectric composites in medical imaging ultrasounds and other acoustic transducers. Recently, new piezoelectric composite transducers have been developed with optimized composite components that have improved thermal stability and mechanical quality factors, making them promising candidates for high temperature, high power transducer applications, such as therapeutic ultrasound, high power ultrasonic wirebonding, high temperature non-destructive testing, and downhole energy harvesting. This paper will present recent developments of piezoelectric composite technology for high temperature and high power applications. The concerns and limitations of using piezoelectric composites will also be discussed, and the expected future research directions will be outlined.

  1. Wideband acoustic activation and detection of droplet vaporization events using a capacitive micromachined ultrasonic transducer

    Science.gov (United States)

    Novell, Anthony; Arena, Christopher B.; Oralkan, Omer; Dayton, Paul A.

    2016-01-01

    An ongoing challenge exists in understanding and optimizing the acoustic droplet vaporization (ADV) process to enhance contrast agent effectiveness for biomedical applications. Acoustic signatures from vaporization events can be identified and differentiated from microbubble or tissue signals based on their frequency content. The present study exploited the wide bandwidth of a 128-element capacitive micromachined ultrasonic transducer (CMUT) array for activation (8 MHz) and real-time imaging (1 MHz) of ADV events from droplets circulating in a tube. Compared to a commercial piezoelectric probe, the CMUT array provides a substantial increase of the contrast-to-noise ratio. PMID:27369143

  2. Modeling Displacement Measurement using Vibration Transducers

    Directory of Open Access Journals (Sweden)

    AGOSTON Katalin

    2014-05-01

    Full Text Available This paper presents some aspects regarding to small displacement measurement using vibration transducers. Mechanical faults, usages, slackness’s, cause different noises and vibrations with different amplitude and frequency against the normal sound and movement of the equipment. The vibration transducers, accelerometers and microphone are used for noise and/or sound and vibration detection with fault detection purpose. The output signal of the vibration transducers or accelerometers is an acceleration signal and can be converted to either velocity or displacement, depending on the preferred measurement parameter. Displacement characteristics are used to indicate when the machine condition has changed. There are many problems using accelerometers to measure position or displacement. It is important to determine displacement over time. To determinate the movement from acceleration a double integration is needed. A transfer function and Simulink model was determinate for accelerometers with capacitive sensing element. Using these models the displacement was reproduced by low frequency input.

  3. Wire-number effects on high-power annular z-pinches and some characteristics at high wire number

    Energy Technology Data Exchange (ETDEWEB)

    SANFORD,THOMAS W. L.

    2000-05-23

    Characteristics of annular wire-array z-pinches as a function of wire number and at high wire number are reviewed. The data, taken primarily using aluminum wires on Saturn are comprehensive. The experiments have provided important insights into the features of wire-array dynamics critical for high x-ray power generation, and have initiated a renaissance in z-pinches when high numbers of wires are used. In this regime, for example, radiation environments characteristic of those encountered during the early pulses required for indirect-drive ICF ignition on the NIF have been produced in hohlraums driven by x-rays from a z-pinch, and are commented on here.

  4. Immune Algorithm Complex Method for Transducer Calibration

    Directory of Open Access Journals (Sweden)

    YU Jiangming

    2014-08-01

    Full Text Available As a key link in engineering test tasks, the transducer calibration has significant influence on accuracy and reliability of test results. Because of unknown and complex nonlinear characteristics, conventional method can’t achieve satisfactory accuracy. An Immune algorithm complex modeling approach is proposed, and the simulated studies on the calibration of third multiple output transducers is made respectively by use of the developed complex modeling. The simulated and experimental results show that the Immune algorithm complex modeling approach can improve significantly calibration precision comparison with traditional calibration methods.

  5. Using XBee transducers for wireless data collection

    Science.gov (United States)

    Ayars, Eric; Lai, Estella

    2010-07-01

    This article describes how to use XBee transducers to create small and lightweight wireless sensors, which send data to a base station for collection and analysis. Data collection is limited to 10-bit accuracy by the XBee hardware. Depending on the type of XBee used, up to six data channels can be transmitted over a range of up to 15 miles. We describe the technical details of the process using the low-power version of the XBee transducer and a three-axis accelerometer chip.

  6. Piezoelectric array elements for sound reconstruction with a digital input

    KAUST Repository

    Carreno, Armando Arpys Arevalo

    2016-10-13

    Various examples are provided for digital sound reconstruction using piezoelectric array elements. In one example, a digital loudspeaker includes a fixed frame and an array of transducers disposed on the fixed frame. Individual transducers of the array of transducers can include a flexible membrane disposed on a piezoelectric actuation element positioned over a corresponding opening that extends through the fixed frame. In another example, a method includes forming a flexible membrane structure on a substrate and backetching the substrate opposite the flexible membrane structure. The flexible membrane structure can be formed by disposing a first electrode layer on a substrate, disposing a piezoelectric layer on the first electrode layer and disposing a second electrode layer on the piezoelectric layer. A flexible membrane layer (e.g., polyimide) can be disposed on the second electrode layer.

  7. Capacitive micromachined ultrasound transducer (cMUT) for immunosensor design.

    Science.gov (United States)

    Ramanaviciene, Almira; Virzonis, Darius; Vanagas, Gailius; Ramanavicius, Arūnas

    2010-07-01

    An affinity sensor based on a capacitive micromachined ultrasound transducer (cMUT) is reported by this Communication. The cMUT micromembrane arrays modified with adsorbed bovine leukemia virus protein gp51 were applied as a biological recognition part. The cMUT-based sensor is shown to be sensitive to the antibodies against bovine leukemia virus protein gp51 (anti-gp51). Two different concentrations of anti-gp51-containing samples and one blank sample without anti-gp51 were tested. The sensitivity of cMUT-based immunosensor is comparable with the sensitivity of a quartz microbalance-based immunosensor. The cMUT array provides a multi-channel system for the measurement of analytical signal. Moreover, two different characteristics--the resonance frequency shift (Deltaf) and the shift of the real part of the electromechanical impedance (DeltaRe)--could have been evaluated simultaneously. Both analytical signals are informative and can be applied for the estimation of immune complex formation. We found the performance of such a system being potentially superior over some other immunosensing techniques. It is more rapid than electrochemical techniques and provides two different informative parameters.

  8. Thermoacoustic power conversion using a piezoelectric transducer.

    Science.gov (United States)

    Jensen, Carl; Raspet, Richard

    2010-07-01

    The predicted efficiency of a simple thermoacoustic waste heat power conversion device has been investigated as part of a collaborative effort combining a thermoacoustic engine with a piezoelectric transducer. Symko et al. [Microelectron. J. 35, 185-191 (2004)] at the University of Utah built high frequency demonstration engines for this application, and Lynn [ASMDC report, accession number ADA491030 (2008)] at the University of Washington designed and built a high efficiency piezoelectric unimorph transducer for electroacoustic conversion. The design presented in this paper is put forward to investigate the potential of a simple high frequency, air filled, standing wave thermoacoustic device to be competitive with other small generator technologies such as thermoelectric devices. The thermoacoustic generator is simulated using a low-amplitude approximation for thermoacoustics and the acoustic impedance of the transducer is modeled using an equivalent circuit model calculated from the transducer's mechanical and electrical properties. The calculations demonstrate that a device performance of around 10% of Carnot efficiency could be expected from the design which is competitive with currently available thermoelectric generators.

  9. Ferroelectret non-contact ultrasonic transducers

    Czech Academy of Sciences Publication Activity Database

    Bovtun, Viktor; Döring, J.; Bartusch, J.; Beck, U.; Erhard, A.; Yakymenko, Y.

    2007-01-01

    Roč. 88, č. 4 (2007), s. 737-743 ISSN 0947-8396 R&D Projects: GA ČR(CZ) GA202/06/0403 Institutional research plan: CEZ:AV0Z10100520 Keywords : ferroelectrets * polymers * ultrasonic transducers Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.857, year: 2007

  10. Linearization of resistance thermometers and other transducers

    DEFF Research Database (Denmark)

    Diamond, Joseph M.

    1970-01-01

    deflection output or to null balance output. The application to the common temperature transducers is considered. It is shown that thermistors, linear metals (e.g., copper), and nickel can be linearized in terms of temperature, but platinum cannot be. If linearization is desired in terms of the reciprocal...

  11. Fiber-optic coupled pressure transducer

    International Nuclear Information System (INIS)

    Tallman, C.R.; Wingate, F.P.; Ballard, E.O.

    1979-01-01

    A fiber-optic coupled pressure transducer was developed for measurement of pressure transients produced by fast electrical discharges in laser cavities. A detailed description of the design and performance will be given. Shock tube performance and measurements in direct electrical discharge regions will be presented

  12. Pushdown machines for the macro tree transducer

    NARCIS (Netherlands)

    Engelfriet, Joost; Vogler, Heiko

    1986-01-01

    The macro tree transducer can be considered as a system of recursive function procedures with parameters, where the recursion is on a tree (e.g., the syntax tree of a program). We investigate characterizations of the class of tree (tree-to-string) translations which is induced by macro tree

  13. Eliminating transducer distortion in acoustic measurements

    DEFF Research Database (Denmark)

    Agerkvist, Finn T.; Torras Rosell, Antoni; McWalter, Richard Ian

    2014-01-01

    This paper investigates the in uence of nonlinear components that contaminate the linear response of acoustic transducer, and presents a method for eliminating the in uence of nonlinearities in acoustic measurements. The method is evaluated on simulated as well as experimental data, and is shown ...

  14. High Thrust-to-Power Annular Engine Technology

    Science.gov (United States)

    Patterson, Michael J.; Thomas, Robert E.; Crofton, Mark W.; Young, Jason A.; Foster, John E.

    2015-01-01

    Gridded ion engines have the highest efficiency and total impulse of any mature electric propulsion technology, and have been successfully implemented for primary propulsion in both geocentric and heliocentric environments with excellent ground/in-space correlation of performance. However, they have not been optimized to maximize thrust-to-power, an important parameter for Earth orbit transfer applications. This publication discusses technology development work intended to maximize this parameter. These activities include investigating the capabilities of a non-conventional design approach, the annular engine, which has the potential of exceeding the thrust-to-power of other EP technologies. This publication discusses the status of this work, including the fabrication and initial tests of a large-area annular engine. This work is being conducted in collaboration among NASA Glenn Research Center, The Aerospace Corporation, and the University of Michigan.

  15. Hydrodynamics of adiabatic inverted annular flow: an experimental study

    International Nuclear Information System (INIS)

    De Jarlais, G.; Ishii, M.

    1983-01-01

    For low-quality film boiling in tubes or rod bundles, the flow pattern may consist of a liquid jet-like core surrounded by a vapor annulus, i.e., inverted annular flow. The stability, shape, and break-up mechanisms of this liquid core must be understood in order to model correctly this regime and to develop appropriate interfacial transfer correlations. This paper reports on a study in which inverted annular flow was simulated in an adiabatic system. Turbulent water jets, issuing downward from long-aspect nozzles were enclosed within cocurrent gas annuli. Jet-core diameter and velocity, and gas-annulus diameter, velocity, and species were varied, yielding liquid Reynolds numbers up to 33,000, void fractions from 0.29 to 0.95, and relative velocities from near zero to over 80 m/s. Jet-core break-up lengths and secondarily, core break-up mechanisms, were observed visually, using strobe lighting

  16. Annular gap solitons in Kerr media with circular gratings

    International Nuclear Information System (INIS)

    Scheuer, Jacob; Malomed, Boris

    2007-01-01

    We introduce standing-light patterns trapped in a Bragg grating written along the radial direction in a self-focusing (SF) or self-defocusing (SDF) optical medium. Unlike previously studied axisymmetric settings that deal with the axial propagation, we consider the propagation of light in the radial directions (outward and inward), which may give rise to annular gap solitons (AGSs), supported by the circular grating. An estimate for the threshold of the modulational instability of the AGS against azimuthal perturbations in the SF medium is obtained analytically, and verified by direct simulations. In the SDF model, stable annular and dipole solitons are found in a numerical form, while multipole patterns and vortex rings are unstable. Similar solitons are possible in the Bose-Einstein condensate

  17. Optical description and design method with annularly stitched aspheric surface.

    Science.gov (United States)

    Cheng, De-Wen; Chen, Xue-Jiao; Xu, Chen; Hu, Yuan; Wang, Yong-Tian

    2015-12-01

    The relentless pressure for designs with new optical functions, small volume, and light weight has greatly increased the importance of aspheric surfaces. In this paper, we propose an annularly stitched aspheric surface (ASAS) description method to increase the freedom and flexibility of imaging system design. The rotationally symmetric ASAS consists of a circular central zone and one or more annular zones. Two neighboring zones are constrained to have the same derivatives on their joint curve, and this means the ASAS is C1 continuous. This finding is proved and verified by the mathematical deduction of the surface formulas. Two optimization strategies and two design methods with the C1 continuous constraints are also discussed. This surface can greatly facilitate the design and even achieve some previously impossible designs without increasing the fabrication difficulty. Two different systems with the proposed ASAS are optimized and the results are presented. The design results verified the practicability of the ASAS.

  18. Annular ring zoom system using two positive axicons

    Science.gov (United States)

    Dickey, Fred M.; Conner, Jacob D.

    2011-10-01

    The production of an annular ring of light with a variable diameter has applications in laser material processing and machining, particle manipulation, and corneal surgery. This can readily be accomplished using a positive and negative axicon pair. However, negative axicons are very expensive and difficult to obtain with small diameters. In this paper, we present a design of an annular ring zoom system using two positive axicons. One axicon is placed a distance before a primary lens that is greater than some prescribed minimum, and the second axicon is placed after the primary lens. The position of the second axicon determines the ring diameter. The ring diameter can be zoomed from some maximum design size to a zero diameter ring (spot). Experimental results from a developmental system will be presented.

  19. The 2005 annular eclipse: a classroom activity at EPLA

    Science.gov (United States)

    Filgaira, H.

    2006-08-01

    In 2005, the 3rd of October, an annular solar eclipse was seen in part of Spain, including the city of Valencia and its surroundings. Last time something similar happened in Valencia was just a century ago. These unusual astronomical events are an excellent opportunity for students to learn astronomy, as they live it and feel part of it. In our school, "Colegio EPLA" at Godella, it was an incomparable opportunity as the annular eclipse happened during playtime. Therefore, for two weeks the school prepared several activities using the eclipse as a central theme (what is called in the Spanish educational model a "transverse subject"), explaining to the students about the eclipse (adapted to their levels), and preparing the pupils for secure eclipse observation: i.e., the children fabricated during class time their own eclipse glasses with black polymer; and for the little ones, the window of a classroom was covered with black polymer for secure observation of the phenomena.

  20. Flow of viscoplastic fluids in eccentric annular geometries

    DEFF Research Database (Denmark)

    Szabo, Peter; Hassager, Ole

    1992-01-01

    A classification of flowfields for the flow of a Bingham fluid in general eccentric annular geometries is presented. Simple arguments show that a singularity can exist in the stress gradient on boundaries between zones with yielded and un-yielded fluid respectively. A Finite Element code is used...... to verify this property of the Bingham fluid. An analytical solution for the flowfield in case of small eccentricities is derived....

  1. Numerical Study of Transition of an Annular Lift Fan Aircraft

    OpenAIRE

    Yun Jiang; Bo Zhang

    2016-01-01

    The present study aimed at studying the transition of annular lift fan aircraft through computational fluid dynamics (CFD) simulations. The oscillations of lift and drag, the optimization for the figure of merit, and the characteristics of drag, yawing, rolling and pitching moments in transition are studied. The results show that a two-stage upper and lower fan lift system can generate oscillations of lift and drag in transition, while a single-stage inner and outer fan lift system can elimin...

  2. Thermohydraulic analysis of smooth and finned annular ducts

    International Nuclear Information System (INIS)

    Braga, C.V.M.

    1987-01-01

    The present work is concerned with the turbulent heat transfer and pressure drop in smooth and finned annular ducts overage heat transfer coefficients have been obtained by means of the heat exchanger theory. In addition, friction factors have also been determined. The experiments were performed by utilizing four double-pipe heat exchangers. The flowing fluids, in the heat exchangers, were air and water. The average heat transfer coefficients, for air flowing in the annular section, were determined by measuring the overall heat transfer coefficients of the heat exchangers. In order to attain fully developed conditions, the heat exchangers had a starting length of 30 hydraulic diameters. The thermal boundary conditions consisted of uniform temperature on the inner surface, the outer surface being insulated. The heat transfer coefficients and friction factors are presented in dimensionaless forms, as functions of the Reynolds number of the flow. The results for the smooth and finned annular ducts were compared. The purpose of such comparison was to study the influence of the fins on the pressure drop and heat transfer rate. In the case of the finned nular ducts, it is shown that the fin efficiency has some fluence on the heat transfer rates. The, a two-dimensional at transfer analysis was performed in order to obtain the n efficiency and the annular region efficiency. It is also shown that the overall thermal performance of finned surfaces epends mainly on the Nusselt number and on the region eficiency. These parameters are presented as functions of the Reynolds number of the flow and the geometry of the problem. (author) [pt

  3. Detonation propagation in annular arcs of condensed phase explosives

    Science.gov (United States)

    Ioannou, Eleftherios; Schoch, Stefan; Nikiforakis, Nikolaos; Michael, Louisa

    2017-11-01

    We present a numerical study of detonation propagation in unconfined explosive charges shaped as an annular arc (rib). Steady detonation in a straight charge propagates at constant speed, but when it enters an annular section, it goes through a transition phase and eventually reaches a new steady state of constant angular velocity. This study examines the speed of the detonation wave along the annular charge during the transition phase and at steady state, as well as its dependence on the dimensions of the annulus. The system is modeled using a recently proposed diffuse-interface formulation which allows for the representation of a two-phase explosive and of an additional inert material. The explosive considered is the polymer-bonded TATB-based LX-17 and is modeled using two Jones-Wilkins-Lee (JWL) equations of state and the ignition and growth reaction rate law. Results show that steady state speeds are in good agreement with experiment. In the transition phase, the evolution of outer detonation speed deviates from the exponential bounded growth function suggested by previous studies. We propose a new description of the transition phase which consists of two regimes. The first regime is caused by local effects at the outer edge of the annulus and leads to a dependence of the outer detonation speed on the angular position along the arc. The second regime is induced by effects originating from the inner edge of the annular charge and leads to the deceleration of the outer detonation until steady state is reached. The study concludes with a parametric study where the dependence of the steady state and the transition phase on the dimensions of the annulus is investigated.

  4. Localized granuloma annulare and autoimmune thyroiditis in a ...

    African Journals Online (AJOL)

    This presentation is a further evidence that GA and autoimmune thyroiditis may be associated. Key Words: Granuloma annulare, Autoimmune thyroiditis. Résumé L'association d'un granulome annulaire (GA) et auto-immunité de la thyroidite a été documenté dans la litterature au cours des 13 cas précédents. Toutefois, la ...

  5. 3-D laser anemometer measurements in an annular seal

    Science.gov (United States)

    Morrison, G. L.; Tatterson, G. B.; Johnson, M. C.

    1988-01-01

    The flow field inside an annular seal with a 0.00127 m clearance was measured using a 3-D laser Doppler anemometer system. Through the use of this system, the mean velocity vector and the entire Reynolds stress tensor distributions were measured for the entire length of the seal (0.0373 m). The seal was operated at a Reynolds number of 27,000 and a Taylor number of 6,600.

  6. Magneto-elastic dynamics and bifurcation of rotating annular plate*

    International Nuclear Information System (INIS)

    Hu Yu-Da; Piao Jiang-Min; Li Wen-Qiang

    2017-01-01

    In this paper, magneto-elastic dynamic behavior, bifurcation, and chaos of a rotating annular thin plate with various boundary conditions are investigated. Based on the thin plate theory and the Maxwell equations, the magneto-elastic dynamic equations of rotating annular plate are derived by means of Hamilton’s principle. Bessel function as a mode shape function and the Galerkin method are used to achieve the transverse vibration differential equation of the rotating annular plate with different boundary conditions. By numerical analysis, the bifurcation diagrams with magnetic induction, amplitude and frequency of transverse excitation force as the control parameters are respectively plotted under different boundary conditions such as clamped supported sides, simply supported sides, and clamped-one-side combined with simply-anotherside. Poincaré maps, time history charts, power spectrum charts, and phase diagrams are obtained under certain conditions, and the influence of the bifurcation parameters on the bifurcation and chaos of the system is discussed. The results show that the motion of the system is a complicated and repeated process from multi-periodic motion to quasi-period motion to chaotic motion, which is accompanied by intermittent chaos, when the bifurcation parameters change. If the amplitude of transverse excitation force is bigger or magnetic induction intensity is smaller or boundary constraints level is lower, the system can be more prone to chaos. (paper)

  7. Development of annular pellet production techniques for PFBR fuel

    International Nuclear Information System (INIS)

    Somayajulu, P.S.; Nehete, Y.G.; Shelke, B.K.; Kumar, Arun; Kamath, H.S.

    2000-01-01

    Advanced Fuel Fabrication Facility (AFFF) at Tarapur is an industrial scale plant for the fabrication of plutonium based ceramic nuclear fuels. Mixed Oxide (MOX) fuel for TAPS is being regularly manufactured in this facility. Efforts are now on to fabricate MOX fuel for the proposed Prototype Fast Breeder Reactors (PFBR). Experimental studies were carried out using natural UO 2 for the fabrication of PFBR fuel pellets. These trials were carried out in glove box condition of the existing fuel pelletisation line, The PFBR fuel pellets are of annular cylindrical shape of around 5.5 mm diameter having internal hole diameter of around 1.7 mm. Apart from meeting physical integrity criteria, the linear mass should be between 2.25 -2.41 gm/cm. Fabrication of annular pellet meeting these specifications require special techniques to be developed. Further, equipment used in the process especially final compaction press should be capable of giving high rate of production. This paper discusses the preliminary work done to fabricate the annular pellets using the existing facilities and the results obtained. (author)

  8. Entrainment in vertical annular two-phase flow

    International Nuclear Information System (INIS)

    Sawant, Pravin; Ishii, Mamoru; Mori, Michitsugu

    2009-01-01

    Prediction of amount of entrained droplets or entrainment fraction in annular two-phase flow is essential for the estimation of dryout condition and analysis of post dryout heat transfer in light water nuclear reactors and steam boilers. In this study, air-water and organic fluid (Freon-113) annular flow entrainment experiments have been carried out in 9.4 and 10.2 mm diameter test sections, respectively. Both the experiments covered three distinct pressure conditions and wide range of liquid and gas flow conditions. The organic fluid experiments simulated high pressure steam-water annular flow conditions. In each of the experiments, measurements of entrainment fraction, droplet entrainment rate and droplet deposition rate have been performed by using a liquid film extraction method. A simple, explicit and non-dimensional correlation developed by Sawant et al. (2008a) for the prediction of entrainment fraction is further improved in this study in order to account for the existence of critical gas and liquid flow rates below which no entrainment is possible. Additionally, a new correlation is proposed for the estimation of minimum liquid film flow rate at the maximum entrainment fraction condition. The improved correlation successfully predicted the newly collected air-water and Freon-113 entrainment fraction data. Furthermore, the correlations satisfactorily compared with the air-water, helium-water and air-genklene experimental data measured by Willetts (1987). (author)

  9. Capacitive pressure transducer using flexible films. Junan film wo mochiita seiden yoryoshiki atsukaku transducer

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Y.; Tsuchida, N.; Imai, K. (Toyota Technological Institute, Aichi (Japan)); Fujita, K. (Nitto Denko Corp., Osaka (Japan)): Tsuboi, O. (Fujitsu Corp., Tokyo (Japan))

    1992-12-20

    This paper describes the design, manufacture, and evaluation of a capacitive pressure transducer made of polyimide films. The structure of a pressure transducer cell was first determined, and then, the deflection-stress and capacitance-load characteristics of the surface film were analyzed using finite element methods. For the practical stage of manufacture, a polyimide film was emboss processed and electrodes were deposited on the film to construct a pressure transducer cell to which a Schmidt-trigger detecting circuit was connected. As a consequence of the examination of operational characteristics of the cell, it was found that the actual relation between the deflection and load approximately agreed with the linear analyses, and that the capacitance depended with little hysteresis on the gap regardless of the native visco-elasticity of the film. Furthermore, small stick-slip vibration of a contact rubber surface was detected by the transducer to verify its high sensitivity. 17 refs., 18 figs.

  10. The influence of annular seal clearance to the critical speed of the multistage pump

    International Nuclear Information System (INIS)

    Wang, J; Shen, H P; Ye, X Y; Hu, J N; Feng, Y N

    2013-01-01

    In the multistage pump of high head, pressure difference in two ends of annular seal clearance and rotor eccentric would produce the sealing fluid force, the effect of which can be expressed by a damping and stiffness coefficient. It has a great influence on the critical speed of the rotor system. In order to research the influence of the annular seal to the rotor system, this paper used CFD method to conduct the numerical simulation for the flow field of annular seal clearance. The radial and tangential forces were obtained to calculate the annular dynamic coefficients. Also dynamic coefficient were obtained by Matlab. The rotor system was modeled using ANSYS finite software and the critical speed with and without annular seal clearance were calculated. The result shows: annular seal's fluid field is under the comprehensive effect of pressure difference and rotor entrainment. Due to the huge pressure difference in front annular seal, fluid flows under pressure difference; the low pressure difference results in the more obvious effect on the clearance field in back annular seal. The first order critical speed increases greatly with the annular seal clearance; while the average growth rate of the second order critical speed is only 3.2%; the third and fourth critical speed decreases little. Based on the above result, the annular seal has great influence to the first order speed, while has little influence on the rest

  11. Array capabilities and future arrays

    International Nuclear Information System (INIS)

    Radford, D.

    1993-01-01

    Early results from the new third-generation instruments GAMMASPHERE and EUROGAM are confirming the expectation that such arrays will have a revolutionary effect on the field of high-spin nuclear structure. When completed, GAMMASHPERE will have a resolving power am order of magnitude greater that of the best second-generation arrays. When combined with other instruments such as particle-detector arrays and fragment mass analysers, the capabilites of the arrays for the study of more exotic nuclei will be further enhanced. In order to better understand the limitations of these instruments, and to design improved future detector systems, it is important to have some intelligible and reliable calculation for the relative resolving power of different instrument designs. The derivation of such a figure of merit will be briefly presented, and the relative sensitivities of arrays currently proposed or under construction presented. The design of TRIGAM, a new third-generation array proposed for Chalk River, will also be discussed. It is instructive to consider how far arrays of Compton-suppressed Ge detectors could be taken. For example, it will be shown that an idealised open-quote perfectclose quotes third-generation array of 1000 detectors has a sensitivity an order of magnitude higher again than that of GAMMASPHERE. Less conventional options for new arrays will also be explored

  12. New type pressure transducer for severe thermal environments

    Science.gov (United States)

    1969-01-01

    Pressure transducer used in a rocket motor chamber to measure the amplitudes and frequencies of dynamic pressures /exceeding 2000 psi/ occurring during unstable combustion. the transducer utilizes a transpirational cooled porous beryllium plug and pressure transmitting column.

  13. Application of a matched filter approach for finite aperture transducers for the synthetic aperture imaging of defects.

    Science.gov (United States)

    Satyanarayan, L; Muralidharan, Ajith; Krishnamurthy, Chittivenkata; Balasubramaniam, Krishnan

    2010-06-01

    The suitability of the synthetic aperture imaging of defects using a matched filter approach on finite aperture transducers was investigated. The first part of the study involved the use a finite-difference time-domain (FDTD) algorithm to simulate the phased array ultrasonic wave propagation in an aluminum block and its interaction with side-drilled hole-like defects. B-scans were generated using the FDTD method for three active aperture transducer configurations of the phased array (a) single element and (b) 16-element linear scan mode, and (c) 16-element steering mode. A matched filter algorithm (MFA) was developed using the delay laws and the spatial impulse response of a finite size rectangular phased array transducer. The conventional synthetic aperture focusing technique (SAFT) algorithm and the MFA were independently applied on the FDTD signals simulated with the probe operating at a center frequency of 5 MHz and the processed B-scans were compared. The second part of the study investigated the capability of the MFA approach to improve the SNR. Gaussian white noise was added to the FDTD generated defect signals. The noisy B-scans were then processed using the SAFT and the MFA and the improvements in the SNR were estimated. The third part of the study investigated the application of the MFA to image and size surface-crack-like defects in pipe specimens obtained using a 45 degrees steered beam from a phased array probe. These studies confirm that MFA is an alternative to SAFT with little additional computational burden. It can also be applied blindly, like SAFT, to effect synthetic focusing with distinct advantages in treating finite transducer effects, and in handling steered beam inspections. Finally, limitations of the MFA in dealing with larger-sized transducers are discussed.

  14. Fourier-Bessel Field Calculation and Tuning of a CW Annular Array

    DEFF Research Database (Denmark)

    Fox, Paul D.; Cheng, Jiqi; Lu, Jian-yu

    2002-01-01

    field by linking the quantized surface pressure profile to a set of limited diffraction Bessel beams propagating into the medium. In the limit, these become a known set of nondiffracting Bessel beams satisfying the lossless linear wave equation, which allow us to derive a linear matrix formulation...

  15. SNP Arrays

    Directory of Open Access Journals (Sweden)

    Jari Louhelainen

    2016-10-01

    Full Text Available The papers published in this Special Issue “SNP arrays” (Single Nucleotide Polymorphism Arrays focus on several perspectives associated with arrays of this type. The range of papers vary from a case report to reviews, thereby targeting wider audiences working in this field. The research focus of SNP arrays is often human cancers but this Issue expands that focus to include areas such as rare conditions, animal breeding and bioinformatics tools. Given the limited scope, the spectrum of papers is nothing short of remarkable and even from a technical point of view these papers will contribute to the field at a general level. Three of the papers published in this Special Issue focus on the use of various SNP array approaches in the analysis of three different cancer types. Two of the papers concentrate on two very different rare conditions, applying the SNP arrays slightly differently. Finally, two other papers evaluate the use of the SNP arrays in the context of genetic analysis of livestock. The findings reported in these papers help to close gaps in the current literature and also to give guidelines for future applications of SNP arrays.

  16. Simulating CMUT Arrays Using Time Domain FEA

    DEFF Research Database (Denmark)

    Engholm, Mathias; Tweedie, Andrew; Jensen, Jonas

    2017-01-01

    PZFlex is a commercial FEA software that has been optimized for the ultrasound industry and is commonly used to design piezoelectric ultrasound transducers. However, PZFlex is not commonly used within the CMUT research field. Nevertheless, it has an explicit modeling approach allowing large...... structures like CMUT arrays to be modeled and its transient analysis intrinsically supplies non-linear and broadband results from a single run. A 3-D model of a CMUT array is developed with multiple cells in each element and one active element surrounded by N passive elements. It is demonstrated...... that the impulse response can directly be used in Field II to assess the image quality of the transducer using the lateral, axial and cystic resolution for two different CMUT designs....

  17. Magnetoelastic Transducer Materials - a Plateable Possibility

    DEFF Research Database (Denmark)

    Jensen, Jens Dahl; Møller, Per

    2001-01-01

    A short presentation of the magnetostriction theory as well as a series of possible applications for magnetoelastic transducers are given. A review of the present state of development for these materials is discussed with relation to the various ways of manufacture. The paper is concluded with th...... as the reference material Terfenol-D were obtained, but reproduction of exact magnetic properties is still critical with the new plating technique.......A short presentation of the magnetostriction theory as well as a series of possible applications for magnetoelastic transducers are given. A review of the present state of development for these materials is discussed with relation to the various ways of manufacture. The paper is concluded...... with the presentation of a method for making magnetoelastic materials by electrochemical deposition (electroless) as tried by the authors in collaboration with the Daimler-Chrysler research centre in Ulm, Germany. First results of this work are both promising and intriguing: Sensitivities of the same order...

  18. Acousto-optical Transducer with Surface Plasmons

    Science.gov (United States)

    Kolomenskii, A. A.; Surovic, E.; Schuessler, H. A.

    2018-04-01

    The surface plasmon resonance (SPR) is a sensitive technique for the detection of changes in dielectric parameters in close proximity to a metal film supporting surface plasmon waves. Here we study the application of the SPR effect to an efficient conversion of an acoustic signal into an optical one. Such a transducer potentially has a large bandwidth and good sensitivity. When an acoustic wave is incident onto a receiving plate positioned within the penetration depth of the surface plasmons, it creates displacements of the surface of the plate and, thus, modulates the dielectric properties in the proximity of the gold film. This modulation, in turn, modifies the light reflection under surface plasmon resonance conditions. We simulate characteristics of this acousto-optical transducer with surface plasmons and provide sets of parameters at the optical wavelength of 800 nm and 633 nm for its realization.

  19. Dissipation in vibrating superleak second sound transducers

    International Nuclear Information System (INIS)

    Giordano, N.

    1985-01-01

    We have performed an experimental study of the generation and detection of second sound in 4 He using vibrating superleak second sound transducers. At temperatures well below T/sub lambda/ and for low driving amplitudes, the magnitude of the generated second sound wave is proportional to the drive amplitude. However, near T/sub lambda/ and for high drive amplitudes this is no longer the case--instead, the second sound amplitude saturates. In this regime we also find that overtones of the drive frequency are generated. Our results suggest that this behavior is due to critical velocity effects in the pores of the superleak in the generator transducer. This type of measurement may prove to be a useful way in which to study critical velocity effects in confined geometries

  20. Passive Mode Carbon Nanotube Underwater Acoustic Transducer

    Science.gov (United States)

    2016-09-20

    irreversible Joule heat) by an electric light bulb . The reciprocal (or reverse) of this process by supplying heat and shining light to the same electric bulb ...limit the invention to the precise form disclosed; and obviously many modifications and variations are possible in light of the above teaching...300151 1 of 14 PASSIVE MODE CARBON NANOTUBE UNDERWATER ACOUSTIC TRANSDUCER STATEMENT OF GOVERNMENT INTEREST [0001] The invention described

  1. Turbine transducer developed for adverse conditions

    International Nuclear Information System (INIS)

    Cooper, D.R.; Edson, J.L.

    1982-01-01

    This paper reviews the latest developments that the Idaho National Engineering Laboratory (INEL) has made on a turbine transducer used in measurement of two-phase flow. It is operated in a modular configuration with a drag transducer to provide mass flow data. Current configurations allow its use in single modules or in multiples to provide flow profile information. The turbine can also provide mass flow data when used with associated instrumentation such as a densitometer. The transducer, which is the product of long investigations and test series, is subject to high vibration loading and high temperatures as well as a borated liquid environment; flow conditions range from all liquid to all steam and from ambient temperatures to over 600 0 F at pressures up to 2200 psi. Graphite bearing and carbide shaft materials were selected to provide corrosion resistance along with mechanical integrity, and resistance to wear. The new turbine design has met all operational requirements in actual use and in extended lifetime tests

  2. High Frequency Guided Wave Virtual Array SAFT

    Science.gov (United States)

    Roberts, R.; Pardini, A.; Diaz, A.

    2003-03-01

    The principles of the synthetic aperture focusing technique (SAFT) are generalized for application to high frequency plate wave signals. It is shown that a flaw signal received in long-range plate wave propagation can be analyzed as if the signals were measured by an infinite array of transducers in an unbounded medium. It is shown that SAFT-based flaw sizing can be performed with as few as three or less actual measurement positions.

  3. Optimization Design Method for the CMOS-type Capacitive Micro-Machined Ultrasonic Transducer

    Directory of Open Access Journals (Sweden)

    D. Y. Chiou

    2011-12-01

    Full Text Available In this study, an integrated modeling technique for characterization and optimization design of the complementary metal-oxide-semiconductor (CMOS capacitive micro-arrayed ultrasonic transducer (pCMOS-CMUT is presented. Electromechanical finite element simulations are performed to investigate its operational characteristics, such as the collapse voltage and the resonant frequency. Both the numerical and experimental results are in good agreement. In order to simultaneously customize the resonant frequency and minimize the collapse voltage, the genetic algorithm (GA is applied to optimize dimensional parameters of the transducer. From the present results, it is concluded that the FE/GA coupling approach provides another efficient numerical tool for multi-objective design of the pCMOS-CMUT.

  4. Language of Transducer Manipulation: Codifying Terms for Effective Teaching.

    Science.gov (United States)

    Bahner, David P; Blickendorf, J Matthew; Bockbrader, Marcia; Adkins, Eric; Vira, Amar; Boulger, Creagh; Panchal, Ashish R

    2016-01-01

    There is a need for consistent, repetitive, and reliable terminology to describe the basic manipulations of the ultrasound transducer. Previously, 5 basic transducer motions have been defined and used in education. However, even with this effort, there is still a lack of consistency and clarity in describing transducer manipulation and motion. In this technical innovation, we describe an expanded definition of transducer motions, which include movements to change the transducer's angle of insonation to the target as well as the location on the body to optimize the ultrasound image. This new terminology may allow for consistent teaching and improved communication in the process of image acquisition.

  5. Ultrasonic properties of all-printed piezoelectric polymer transducers

    Science.gov (United States)

    Wagle, Sanat; Decharat, Adit; Bodö, Peter; Melandsø, Frank

    2013-12-01

    The ability of producing ultrasonic transducers from screen-printing has been explored experimentally, through printing and characterization of a large number of transducers. In an all-printed test design, 124 transducers with four different electrode sizes ranging from 1 to 4.9 mm2, were printed layer-by-layer on a high performance polyethyleneimine polymer. Inks from ferroelectric and conductive polymers were applied to the active part of a transducer, to provide a good acoustical match between the individual layers. Ultrasonic characterizations of the transducers done by two independent methods provided a broad-banded frequency response with a maximum response around 100 MHz.

  6. Electron beam diagnostic system using computed tomography and an annular sensor

    Science.gov (United States)

    Elmer, John W.; Teruya, Alan T.

    2014-07-29

    A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by the annular sensor structure.

  7. High-frequency CMUT arrays for high-resolution medical imaging

    Science.gov (United States)

    Yeh, David T.; Oralkan, Omer; Ergun, Arif S.; Zhuang, Xuefeng; Wygant, Ira O.; Khuri-Yakub, Butrus T.

    2005-04-01

    Applications of ultrasonic imaging in fields such as dermatology, ophthalmology, and cardiovascular medicine require very high resolution. Limitations in existing transducer technologies inhibit the development of high-frequency arrays, which would allow the use of dynamic focusing and enable higher frame rates. As an alternative, capacitive micromachined ultrasonic transducer (CMUT) technology, using integrated circuit fabrication techniques, can provide arrays with the small dimensions required for high-frequency operation. We have designed and fabricated several linear and ring arrays of CMUTs to operate in the 10 to 50 MHz range. These new arrays are made with the wafer bonding process. The ring arrays in particular demonstrate the feasibility of thinning the transducer to aid packaging in intravascular applications. This study shows that CMUTs can be made for high-frequency operation. Both transducers for use in conventional and collapse-mode operation have been designed and characterized. The results demonstrate that CMUT is an appropriate technology for building high-frequency arrays. A linear array of high-voltage pulser and amplifier circuits has also been designed for use with an array of CMUTs to enable real-time imaging applications. Pulse-echo results from the sixteen-channel array have been demonstrated.

  8. An intra-bone axial load transducer: development and validation in an in-vitro radius model.

    Science.gov (United States)

    Knowles, Nikolas K; Gladwell, Michael; Ferreira, Louis M

    2015-12-01

    Accurate measurement of forces through the proximal radius can assess the effects of some surgical procedures on radioulnar load sharing, but is difficult to achieve given the redundant loading nature of the musculoskeletal system. Previously reported devices have relied on indirect measurements that may alter articular joint location and function. An axial load transducer interposed in the diaphysis of the radius may accurately quantify unknown axial loads of the proximal radius, and maintain articular location. An in-vitro radius model was developed by interposing an axial load transducer in the diaphysis of the proximal radius. Static loads of 20, 40, 60, 80, and 100 N were applied with a servo-hydraulic actuator to the native radial head at angles of 10°, 20°, 30°, and 40° in the anterior, posterior, medial and lateral directions. Linear regression of five repeatability trials showed excellent agreement between the transducer and applied loads (R (2) = 1 for all trials). For off-axis net joint loads, the majority of measured loading errors were within the inter-quartile range for mean loads up to 80 N. Loads below 80 N and outside the inter-quartile range had errors of less than 1 N. The repeatability and off-axis net joint load results of this study validate the effectiveness of the interposed axial load transducer to accurately quantify proximal radius loads. The surgical technique preserves the native articular location and soft-tissue constructs, like the annular ligament. The modular design allows for testing the effects of length-changing osteotomies in subsequent biomechanical studies.

  9. Eigenbeamforming array systems for sound source localization

    DEFF Research Database (Denmark)

    Tiana Roig, Elisabet

    Microphone array technology has been widely used for the localization of sound sources. In particular, beamforming is a well-established signal processing method that maps the position of acoustic sources by steering the array transducers toward different directions electronically. The present Ph...... scatterer is recommended instead. A better visualization in the entire frequency range can be achieved with deconvo- lution methods, as they allow the recovery of the sound source distribution from a given beamformed map. Three efficient methods based on spectral procedures, originally conceived for planar...

  10. Onset of nucleate boiling and onset of fully developed subcooled boiling detection using pressure transducers signals spectral analysis

    International Nuclear Information System (INIS)

    Maprelian, Eduardo; Castro, Alvaro Alvim de; Ting, Daniel Kao Sun

    1999-01-01

    The experimental technique used for detection of subcooled boiling through analysis of the fluctuation contained in pressure transducers signals is presented. The experimental part of this work was conducted at the Institut fuer Kerntechnik und zertoerungsfreie Pruefverfahren von Hannover (IKPH, Germany) in a thermal-hydraulic circuit with one electrically heated rod with annular geometry test section. Piezo resistive pressure sensors are used for onset of nucleate boiling (ONB) and onset of fully developed boiling (OFDB) detection using spectral analysis/signal correlation techniques. Experimental results are interpreted by phenomenological analysis of these two points and compared with existing correlation. The results allows us to conclude that this technique is adequate for the detection and monitoring of the ONB and OFDB. (author)

  11. Cylindrical plasmas generated by an annular beam of ultraviolet light

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, D. M., E-mail: dmt107@imperial.ac.uk [Blackett Laboratory, Imperial College London, Prince Consort Road, London SW7 2BW (United Kingdom); Allen, J. E., E-mail: John.Allen@maths.ox.ac.uk [Blackett Laboratory, Imperial College London, Prince Consort Road, London SW7 2BW (United Kingdom); University College, University of Oxford, Oxford OX1 4BH, United Kingdom and OCIAM, Mathematical Institute, University of Oxford, Oxford OX2 6GG (United Kingdom)

    2015-07-15

    We investigate a cylindrical plasma system with ionization, by an annular beam of ultraviolet light, taking place only in the cylinder's outer region. In the steady state, both the outer and inner regions contain a plasma, with that in the inner region being uniform and field-free. At the interface between the two regions, there is an infinitesimal jump in ion density, the magnitude approaching zero in the quasi-neutral (λ{sub D} → 0) limit. The system offers the possibility of producing a uniform stationary plasma in the laboratory, hitherto obtained only with thermally produced alkali plasmas.

  12. Study and optimization of an annular photocatalytic slurry reactor.

    Science.gov (United States)

    Camera-Roda, Giovanni; Santarelli, Francesco; Panico, Mauro

    2009-05-01

    The experimental results obtained for the photocatalytic degradation of a model organic dye in an annular slurry reactor are analyzed with the aid of a mathematical model. The model is used also to study the effects on the performances of many operative conditions: flow rate, photocatalyst concentration, power of the lamp, size of the photocatalytic particles, dimensions of the reactor. The investigation demonstrates that the rate of the process is often limited by the radiant energy transfer and that some simple rules can be followed in order to optimize different yields and the observed rate of reaction.

  13. Replacement fuel scoping studies for the Annular Core Research Reactor

    International Nuclear Information System (INIS)

    Hays, K.; Martin, L.; Parma, E.

    1995-01-01

    Sandia National Laboratories Annular Core Research Reactor (ACRR) is undertaking a new mission for the Department of Energy: production of the radioisotope 99 Mo used in nuclear medicine applications. Isotope production is significantly different from previous programs conducted at the ACRR that typically required high intensity, short duration pulses. The current UO 2 -BeO fuel will power the initial startup phase of the production program, and can perform exceptionally well for this mission. However, this type of fuel is no longer available, commercially or otherwise. This paper presents the results of some preliminary studies of commercially available fuels

  14. Final Technical Report for the MIT Annular Fuel Research Project

    International Nuclear Information System (INIS)

    Mujid S. Kazimi; Pavel Hejzlar

    2008-01-01

    MIT-NFC-PR-082 (January 2006) Abstract This summary provides an overview of the results of the U.S. DOE funded NERI (Nuclear Research Energy Initiative) program on development of the internally and externally cooled annular fuel for high power density PWRs. This new fuel was proposed by MIT to allow a substantial increase in power density (on the order of 30% or higher) while maintaining or improving safety margins. A comprehensive study was performed by a team consisting of MIT (lead organization), Westinghouse Electric Corporation, Gamma Engineering Corporation, Framatome ANP(formerly Duke Engineering) and Atomic Energy of Canada Limited

  15. Broadband acoustic phased array with subwavelength active tube array

    Science.gov (United States)

    Li, Xiao-Yan; Yang, Zhang-Zhao; Zhu, Yi-Fan; Zou, Xin-Ye; Cheng, Jian-Chun

    2018-02-01

    Acoustic metasurfaces provide a way to manipulate wavefronts at anomalous reflection or refraction angles through subwavelength structures. Here, based on the generalized Snell's refraction law for acoustic metasurfaces and the classical acoustic phased array (PA) theory, a broadband acoustic PA with a subwavelength active tube array has been proposed to form a special acoustic beam and to determine the directivity characteristics of the acoustic source. Theoretical analysis shows that the dispersionless wavefront manipulation can be realized by the gradient model of the active tube array, and a wide working frequency band can be obtained in practical applications from the simulated and experimental results. The numerical results of forming a special acoustic beam and establishing an acoustic focus model with an arbitrary focal position are consistent with the theoretical predictions. The experimental results agree well with the simulated results in the model of forming the acoustic beam of 45 ° . By combining acoustic metamaterials and conventional acoustic PA, the model of the active tube array paves a way to design a composite acoustic PA with high radiation efficiency and system robustness without the need for any complex circuit control system. This design concept is expected to be used in the design of ultrasonic therapy devices and high-efficiency transducers.

  16. Experimental Analysis of Bisbenzocyclobutene Bonded Capacitive Micromachined Ultrasonic Transducers.

    Science.gov (United States)

    Manwar, Rayyan; Chowdhury, Sazzadur

    2016-06-24

    Experimental measurement results of a 1.75 mm × 1.75 mm footprint area Capacitive Micromachined Ultrasonic Transducer (CMUT) planar array fabricated using a bisbenzocyclobutene (BCB)-based adhesive wafer bonding technique has been presented. The array consists of 40 × 40 square diaphragm CMUT cells with a cavity thickness of 900 nm and supported by 10 µm wide dielectric spacers patterned on a thin layer of BCB. A 150 µm wide one µm thick gold strip has been used as the contact pad for gold wire bonding. The measured resonant frequency of 19.3 MHz using a Polytec™ laser Doppler vibrometer (Polytec™ MSA-500) is in excellent agreement with the 3-D FEA simulation result using IntelliSuite™. An Agilent ENA5061B vector network analyzer (VNA) has been used for impedance measurement and the resonance and anti-resonance values from the imaginary impedance curve were used to determine the electromechanical coupling co-efficient. The measured coupling coefficient of 0.294 at 20 V DC bias exhibits 40% higher transduction efficiency as compared to a measured value published elsewhere for a silicon nitride based CMUT. A white light interferometry method was used to measure the diaphragm deflection profiles at different DC bias. The diaphragm center velocity was measured for different sub-resonant frequencies using a Polytec™ laser Doppler vibrometer that confirms vibration of the diaphragm at different excitation frequencies and bias voltages. Transmit and receive operations of CMUT cells were characterized using a pitch-catch method and a -6 dB fractional bandwidth of 23% was extracted from the received signal in frequency domain. From the measurement, it appears that BCB-based CMUTs offer superior transduction efficiency as compared to silicon nitride or silicon dioxide insulator-based CMUTs, and provide a very uniform deflection profile thus making them a suitable candidate to fabricate highly energy efficient CMUTs.

  17. Linear and nonlinear stability of periodic orbits in annular billiards.

    Science.gov (United States)

    Dettmann, Carl P; Fain, Vitaly

    2017-04-01

    An annular billiard is a dynamical system in which a particle moves freely in a disk except for elastic collisions with the boundary and also a circular scatterer in the interior of the disk. We investigate the stability properties of some periodic orbits in annular billiards in which the scatterer is touching or close to the boundary. We analytically show that there exist linearly stable periodic orbits of an arbitrary period for scatterers with decreasing radii that are located near the boundary of the disk. As the position of the scatterer moves away from a symmetry line of a periodic orbit, the stability of periodic orbits changes from elliptic to hyperbolic, corresponding to a saddle-center bifurcation. When the scatterer is tangent to the boundary, the periodic orbit is parabolic. We prove that slightly changing the reflection angle of the orbit in the tangential situation leads to the existence of Kolmogorov-Arnold-Moser islands. Thus, we show that there exists a decreasing to zero sequence of open intervals of scatterer radii, along which the billiard table is not ergodic.

  18. A Compact Annular Ring Microstrip Antenna for WSN Applications

    Directory of Open Access Journals (Sweden)

    Daihua Wang

    2012-06-01

    Full Text Available A compact annular ring microstrip antenna was proposed for a wireless sensor network (WSN application in the 2.4 GHz band. In this paper the major considerations of the conformal antenna design were the compact size and the impact on antenna’s performance of a steel installation base. By using a chip resistor of large resistance (120 Ω the antenna size was reduced to 38% of that a conventional annular ring patch antenna. With the addition of the steel installation base the resonant frequency of the antenna increases about 4.2% and the bandwidth reduces from 17.5% to 11.7% by adjusting the load resistance simultaneously. Several key parameters were discussed and optimized, and the antenna was fabricated and its performance measured. The antenna is well matched at 2.4 GHz with 34.2 dB return loss and –2.5 dBi peak gain. Meanwhile, it exhibits excellent radiation patterns with very low cross-polarization levels.

  19. Numerical Simulation of Barite Sag in Pipe and Annular Flow

    Directory of Open Access Journals (Sweden)

    Patrick Kabanda

    2017-01-01

    Full Text Available With the ever increasing global energy demand and diminishing petroleum reserves, current advances in drilling technology have resulted in numerous directional wells being drilled as operators strive to offset the ever-rising operating costs. In as much as deviated-well drilling allows drillers to exploit reservoir potential by penetrating the pay zone in a horizontal, rather than vertical, fashion, it also presents conditions under which the weighting agents can settle out of suspension. The present work is categorized into two parts. In the first part, governing equations were built inside a two-dimensional horizontal pipe geometry and the finite element method utilized to solve the equation-sets. In the second part, governing equations were built inside a three-dimensional horizontal annular geometry and the finite volume method utilized to solve the equation-sets. The results of the first part of the simulation are the solid concentration, mixture viscosity, and a prediction of the barite bed characteristics. For the second part, simulation results show that the highest occurrence of barite sag is at low annular velocities, nonrotating drill pipe, and eccentric drill pipe. The CFD approach in this study can be utilized as a research study tool in understanding and managing the barite sag problem.

  20. Oscillation Characteristics of Thermocapillary Convection in An Open Annular Pool

    Science.gov (United States)

    Duan, Li; Kang, Qi; Zhang, Di

    2016-07-01

    Temperature oscillation characteristics and free surface deformation are essential phenomena in fluids with free surface. We report experimental oscillatory behaviors for hydrothermal wave instability in thermocapillary-driven flow in an open annular pool of silicone oil. The annular pool is heated from the inner cylindrical wall with the radius 4mm and cooled at the outer wall with radius 20mm, and the depth of the silicone oil layer is in the range of 0.8mm-3mm.Temperature difference between the two sidewalls was increased gradually, and the flow will become unstable via a super critical temperature difference. In the present paper we used T-type thermocouple measuring the single-point temperature inside the liquid layer and captured the tiny micrometer wave signal through a high-precision laser displacement sensor. The critical temperature difference and critical Ma number of onset of oscillation have been obtained. We discussed the critical temperature difference and critical Marangoni number varies with the change of the depth of liquid layer, and the relationship between the temperature oscillation and surface oscillation has been discussed. Experimental results show that temperature oscillation and surface oscillation start almost at the same time with similar spectrum characteristic.

  1. CFD simulation of slurry flow in annular pipelines

    Science.gov (United States)

    Sultan, Rasel A.; Rahman, M. A.; Rushd, S.; Zendehboudi, S.

    2017-12-01

    Three-dimensional CFD modeling of two-phase slurry flows is demonstrated in this paper. The flow domain consists of a vertically oriented annular pipe with outer and inner diameter of 0.125 m and 0.025 m, respectively. A mixture velocity range of 0.0738-0.197 m/s and overall volumetric concentration range of 0.8%-1.8% with 0.23 mm grain size (dp) are used for the simulation. Eulerian model with Reynolds Stress Model (RSM) for turbulence closure is adopted to analyze the monodispersed sand particles of varying granular diameters. The objective of this work is to study the slurry flow using CFD simulation and validating the simulation with experimental studies available in the literature. The simulated pressure losses are found to be in good agreement with experimental results at different conditions. Pressure drop per meter or pressure gradient increases with flow velocity of mixture but after a peak point pressure gradient decreases with the increasing velocity. These phenomena in vertical annular flow and its reasons are described in this paper. Effects of efflux solid concentration of slurry on pressure gradient is also studied.

  2. Portal annular pancreas: a systematic review of a clinical challenge.

    Science.gov (United States)

    Harnoss, Jonathan M; Harnoss, Julian C; Diener, Markus K; Contin, Pietro; Ulrich, Alexis B; Büchler, Markus W; Schmitz-Winnenthal, Friedrich H

    2014-10-01

    Portal annular pancreas (PAP) is an asymptomatic congenital pancreas anomaly, in which portal and/or mesenteric veins are encased by pancreas tissue. The aim of the study was to determine the role of PAP in pancreatic surgery as well as its management and potential complication, specifically, postoperative pancreatic fistula (POPF).On the basis of a case report, the MEDLINE and ISI Web of Science databases were systematically reviewed up to September 2012. All articles describing a case of PAP were considered.In summary, 21 studies with 59 cases were included. The overall prevalence of PAP was 2.4% and the patients' mean (SD) age was 55.9 (16.2) years. The POPF rate in patients with PAP (12 pancreaticoduodenectomies and 3 distal pancreatectomies) was 46.7% (in accordance with the definition of the International Study Group of Pancreatic Surgery).Portal annular pancreas is a quite unattended pancreatic variant with high prevalence and therefore still remains a clinical challenge to avoid postoperative complications. To decrease the risk for POPF, attentive preoperative diagnostics should also focus on PAP. In pancreaticoduodenectomy, a shift of the resection plane to the pancreas tail should be considered; in extensive pancreatectomy, coverage of the pancreatic remnant by the falciform ligament could be a treatment option.

  3. Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging.

    Science.gov (United States)

    Wygant, Ira O; Zhuang, Xuefeng; Yeh, David T; Oralkan, Omer; Sanli Ergun, A; Karaman, Mustafa; Khuri-Yakub, Butrus T

    2008-02-01

    For three-dimensional (3D) ultrasound imaging, connecting elements of a two-dimensional (2D) transducer array to the imaging system's front-end electronics is a challenge because of the large number of array elements and the small element size. To compactly connect the transducer array with electronics, we flip-chip bond a 2D 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array to a custom-designed integrated circuit (IC). Through-wafer interconnects are used to connect the CMUT elements on the top side of the array with flip-chip bond pads on the back side. The IC provides a 25-V pulser and a transimpedance preamplifier to each element of the array. For each of three characterized devices, the element yield is excellent (99 to 100% of the elements are functional). Center frequencies range from 2.6 MHz to 5.1 MHz. For pulse echo operation, the average - 6-dB fractional bandwidth is as high as 125%. Transmit pressures normalized to the face of the transducer are as high as 339 kPa and input-referred receiver noise is typically 1.2 to 2.1 mPa/pHz. The flip-chip bonded devices were used to acquire 3D synthetic aperture images of a wire-target phantom. Combining the transducer array and IC, as shown in this paper, allows for better utilization of large arrays, improves receive sensitivity, and may lead to new imaging techniques that depend on transducer arrays that are closely coupled to IC electronics.

  4. Capacitive micromachined ultrasonic transducer based tilt sensing

    Science.gov (United States)

    Yu, Hongbin; Guo, Bin; Haridas, Kuruveettil; Lin, Tsu-Hui; Hao Cheong, Jia; Lin Tsai, Ming; Boon Yee, Tack

    2012-10-01

    In this paper, a tilt sensing mechanism based on the capacitive micromachined ultrasound transducers (CMUTs) is presented. By measuring the difference in the time of flight of various pulse-echo signals from different CMUT transmitting elements to one common receiving element in the oil bath, the tilt angle of the oil surface can be determined. With the proposed device, the maximum tilt angles of 20° and 28° have been measured in the clockwise and counterclockwise directions, respectively, and the difference between the measured and the theoretical values of the tilt angle was found to be within 0.05° during the whole test.

  5. Na, K-ATPase as signaling transducer

    OpenAIRE

    Li, Juan

    2007-01-01

    It is now generally agreed that Na,K-ATPase (NKA), in addition to its role in the maintenance of Na+ and K+ gradients across the cell membrane, is a signal transducer. Our group has identified a novel signaling pathway where NKA interact with IP3R to form a signaling microdomain. Ouabain, a specific ligand of NKA, activates this pathway, triggers slow Ca2+ oscillations and activates NF-κB. In current study, the molecular mechanisms and some important downstream effects of NK...

  6. Filter arrays

    Energy Technology Data Exchange (ETDEWEB)

    Page, Ralph H.; Doty, Patrick F.

    2017-08-01

    The various technologies presented herein relate to a tiled filter array that can be used in connection with performance of spatial sampling of optical signals. The filter array comprises filter tiles, wherein a first plurality of filter tiles are formed from a first material, the first material being configured such that only photons having wavelengths in a first wavelength band pass therethrough. A second plurality of filter tiles is formed from a second material, the second material being configured such that only photons having wavelengths in a second wavelength band pass therethrough. The first plurality of filter tiles and the second plurality of filter tiles can be interspersed to form the filter array comprising an alternating arrangement of first filter tiles and second filter tiles.

  7. Robustness of a Mixed-Order Ambisonics Microphone Array for Sound Field Reproduction

    DEFF Research Database (Denmark)

    Marschall, Marton; Favrot, Sylvain Emmanuel; Buchholz, Jörg

    2012-01-01

    Spherical microphone arrays can be used to capture and reproduce the spatial characteristics of acoustic scenes. A mixed-order Ambisonics (MOA) approach was recently proposed to improve the horizontal spatial resolution of microphone arrays with a given number of transducers. In this paper...

  8. Multiple lesions of granuloma annulare on the hand in a patient with scabies

    Directory of Open Access Journals (Sweden)

    Al Aboud K

    2011-08-01

    Full Text Available Khalid Al Aboud1, Daifullah Al Aboud21Department of Dermatology, King Faisal Hospital, Makkah; 2Department of Dermatology, Taif University, Taif, Kingdom of Saudi ArabiaAbstract: Granuloma annulare induced by scabies infection has been described previously in three patients. In this report, we share our observation of a fourth case.Keywords: granuloma annulare, scabies, skin

  9. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area...

  10. Quasi-static transient thermal stresses in a thick annular disc

    Indian Academy of Sciences (India)

    in a thin annular disc. Also Deshmukh 2002 studied transient heat conduction problem in a thin hollow cylinder and determined thermal stresses. ... containers for hot gases or liquids, in the foundations for furnaces, etc. 2. Formulation of the problem. Consider a thick a annular disc of thickness 2h occupying space D defined ...

  11. Analytical solution of neutron transport equation in an annular reactor with a rotating pulsed source

    International Nuclear Information System (INIS)

    Teixeira, Paulo Cleber Mendonca

    2002-12-01

    In this study, an analytical solution of the neutron transport equation in an annular reactor is presented with a short and rotating neutron source of the type S(x) δ (x- Vt), where V is the speed of annular pulsed reactor. The study is an extension of a previous study by Williams [12] carried out with a pulsed source of the type S(x) δ (t). In the new concept of annular pulsed reactor designed to produce continuous high flux, the core consists of a subcritical annular geometry pulsed by a rotating modulator, producing local super prompt critical condition, thereby giving origin to a rotating neutron pulse. An analytical solution is obtained by opening up of the annular geometry and applying one energy group transport theory in one dimension using applied mathematical techniques of Laplace transform and Complex Variables. The general solution for the flux consists of a fundamental mode, a finite number of harmonics and a transient integral. A condition which limits the number of harmonics depending upon the circumference of the annular geometry has been obtained. Inverse Laplace transform technique is used to analyse instability condition in annular reactor core. A regenerator parameter in conjunction with perimeter of the ring and nuclear properties is used to obtain stable and unstable harmonics and to verify if these exist. It is found that the solution does not present instability in the conditions stated in the new concept of annular pulsed reactor. (author)

  12. Flow Characteristics and Sizing of Annular Seat Valves for Digital Displacement Machines

    DEFF Research Database (Denmark)

    Nørgård, Christian; Bech, Michael Møller; Andersen, Torben O.

    2018-01-01

    This paper investigates the steady-state flow characteristics and power losses of annular seat valves for digital displacement machines. Annular seat valves are promising candidates for active check-valves used in digital displacement fluid power machinery which excels in efficiency in a broad op...

  13. Core-annular flow through a horizontal pipe : Hydrodynamic counterbalancing of buoyancy force on core

    NARCIS (Netherlands)

    Ooms, G.; Vuik, C.; Poesio, P.

    2007-01-01

    A theoretical investigation has been made of core-annular flow: the flow of a high-viscosity liquid core surrounded by a low-viscosity liquid annular layer through a horizontal pipe. Special attention is paid to the question of how the buoyancy force on the core, caused by a density difference

  14. Tunable optical lens array using viscoelastic material and acoustic radiation force

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, Daisuke, E-mail: dkoyama@mail.doshisha.ac.jp; Kashihara, Yuta; Matsukawa, Mami [Faculty of Science and Engineering, Doshisha University, 1-3 Tataramiyakodani, Kyotanabe 610-0321 (Japan); Wave Electronics Research Center, Doshisha University, 1-3 Tataramiyakodani, Kyotanabe 610-0321 (Japan); Hatanaka, Megumi [Faculty of Life and Medical Sciences, Doshisha University, 1-3 Tataramiyakodani, Kyotanabe 610-0321 (Japan); Wave Electronics Research Center, Doshisha University, 1-3 Tataramiyakodani, Kyotanabe 610-0321 (Japan); Nakamura, Kentaro [Precision and Intelligence Laboratory, Tokyo Institute of Technology, 4259-R2-26, Nagatsutacho, Midoriku, Yokohama 226-8503 (Japan)

    2015-10-28

    A movable optical lens array that uses acoustic radiation force was investigated. The lens array consists of a glass plate, two piezoelectric bimorph transducers, and a transparent viscoelastic gel film. A cylindrical lens array with a lens pitch of 4.6 mm was fabricated using the acoustic radiation force generated by the flexural vibration of the glass plate. The focal point and the positioning of the lenses can be changed using the input voltage and the driving phase difference between the two transducers, respectively.

  15. Parameter sensitivity study of a Field II multilayer transducer model on a convex transducer

    DEFF Research Database (Denmark)

    Bæk, David; Jensen, Jørgen Arendt; Willatzen, Morten

    2009-01-01

    ultrasound imaging transducer (Bæk et al. ICU 2009). The model benefits from its 1D simplicity and hasshown to give an amplitude error around 1.7‐2 dB. However, any prediction of amplitude, phase, and attenuation of pulses relies on the accuracy of manufacturer supplied material characteristics, which may...

  16. Annular core liquid-salt cooled reactor with multiple fuel and blanket zones

    Science.gov (United States)

    Peterson, Per F.

    2013-05-14

    A liquid fluoride salt cooled, high temperature reactor having a reactor vessel with a pebble-bed reactor core. The reactor core comprises a pebble injection inlet located at a bottom end of the reactor core and a pebble defueling outlet located at a top end of the reactor core, an inner reflector, outer reflector, and an annular pebble-bed region disposed in between the inner reflector and outer reflector. The annular pebble-bed region comprises an annular channel configured for receiving pebble fuel at the pebble injection inlet, the pebble fuel comprising a combination of seed and blanket pebbles having a density lower than the coolant such that the pebbles have positive buoyancy and migrate upward in said annular pebble-bed region toward the defueling outlet. The annular pebble-bed region comprises alternating radial layers of seed pebbles and blanket pebbles.

  17. Explicit relations between elastic and conductive properties of materials containing annular cracks.

    Science.gov (United States)

    Sevostianov, Igor

    2003-05-15

    The impact of annular cracks on the effective elastic and conductive properties of a material is analysed. The compliance contribution tensor of an annular crack - the quantity that determines the increase in compliance of a solid due to introduction of such a crack - is derived analytically. The resistivity contribution tensor of an annular crack is calculated numerically. It is shown that an effective circular crack, i.e. a crack which yields the same change in elastic/conductive properties of a material as the given annular crack, can be chosen to match both of these tensors. Using this result, the explicit relation between elastic and conductive properties of a material containing annular cracks is obtained. The relation is derived using a non-interaction approximation. Applicability of the derived formulae to real materials (to plasma-sprayed coatings, in particular) is discussed.

  18. Underwater pipeline impact localization using piezoceramic transducers

    Science.gov (United States)

    Zhu, Junxiao; Ho, Siu Chun Michael; Patil, Devendra; Wang, Ning; Hirsch, Rachel; Song, Gangbing

    2017-10-01

    Reports indicated that impact events accounted for 47% of offshore pipeline failures, which calls for impact detection and localization for subsea pipelines. In this paper, an innovative method for rapid localization of impacts on underwater pipelines utilizing a novel determination technique for both arrival-time and group velocity (ATGV) of ultrasonic guided waves with lead zirconate titanate (PZT) transducers is described. PZT transducers mounted on the outer surface of a model pipeline were utilized to measure ultrasonic guided waves generated by impact events. Based on the signals from PZT sensors, the ATGV technique integrates wavelet decomposition, Hilbert transform and statistical analysis to pinpoint the arrival-time of the designated ultrasonic guided waves with a specific group velocity. Experimental results have verified the effectiveness and the localization accuracy for eight impact points along a model underwater pipeline. All estimations errors were small and were comparable with the wavelength of the designated ultrasonic guided waves. Furthermore, the method is robust against the low frequency structural vibration introduced by other external forces.

  19. Acoustic lens for capacitive micromachined ultrasonic transducers

    Science.gov (United States)

    Chang, Chienliu; Firouzi, Kamyar; Park, Kwan Kyu; Sarioglu, Ali Fatih; Nikoozadeh, Amin; Yoon, Hyo-Seon; Vaithilingam, Srikant; Carver, Thomas; Khuri-Yakub, Butrus T.

    2014-08-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with traditional piezoelectric transducers in therapeutic ultrasound applications. In this paper we have designed, fabricated and developed an acoustic lens formed on the CMUT to mechanically focus ultrasound. The acoustic lens was designed based on the paraxial theory and made of silicone rubber for acoustic impedance matching and encapsulation. The CMUT was fabricated based on the local oxidation of silicon (LOCOS) and fusion-bonding. The fabricated CMUT was verified to behave like an electromechanical resonator in air and exhibited wideband response with a center frequency of 2.2 MHz in immersion. The fabrication for the acoustic lens contained two consecutive mold castings and directly formed on the surface of the CMUT. Applied with ac burst input voltages at the center frequency, the CMUT with the acoustic lens generated an output pressure of 1.89 MPa (peak-to-peak) at the focal point with an effective focal gain of 3.43 in immersion. Compared to the same CMUT without a lens, the CMUT with the acoustic lens demonstrated the ability to successfully focus ultrasound and provided a viable solution to the miniaturization of the multi-modality forward-looking endoscopes without electrical focusing.

  20. Acoustic lens for capacitive micromachined ultrasonic transducers

    International Nuclear Information System (INIS)

    Chang, Chienliu; Firouzi, Kamyar; Sarioglu, Ali Fatih; Nikoozadeh, Amin; Yoon, Hyo-Seon; Vaithilingam, Srikant; Carver, Thomas; Khuri-Yakub, Butrus T; Kyu Park, Kwan

    2014-01-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with traditional piezoelectric transducers in therapeutic ultrasound applications. In this paper we have designed, fabricated and developed an acoustic lens formed on the CMUT to mechanically focus ultrasound. The acoustic lens was designed based on the paraxial theory and made of silicone rubber for acoustic impedance matching and encapsulation. The CMUT was fabricated based on the local oxidation of silicon (LOCOS) and fusion-bonding. The fabricated CMUT was verified to behave like an electromechanical resonator in air and exhibited wideband response with a center frequency of 2.2 MHz in immersion. The fabrication for the acoustic lens contained two consecutive mold castings and directly formed on the surface of the CMUT. Applied with ac burst input voltages at the center frequency, the CMUT with the acoustic lens generated an output pressure of 1.89 MPa (peak-to-peak) at the focal point with an effective focal gain of 3.43 in immersion. Compared to the same CMUT without a lens, the CMUT with the acoustic lens demonstrated the ability to successfully focus ultrasound and provided a viable solution to the miniaturization of the multi-modality forward-looking endoscopes without electrical focusing. (paper)

  1. A Prototype PZT Matrix Transducer With Low-Power Integrated Receive ASIC for 3-D Transesophageal Echocardiography.

    Science.gov (United States)

    Chen, Chao; Raghunathan, Shreyas B; Yu, Zili; Shabanimotlagh, Maysam; Chen, Zhao; Chang, Zu-yao; Blaak, Sandra; Prins, Christian; Ponte, Jacco; Noothout, Emile; Vos, Hendrik J; Bosch, Johan G; Verweij, Martin D; de Jong, Nico; Pertijs, Michiel A P

    2016-01-01

    This paper presents the design, fabrication, and experimental evaluation of a prototype lead zirconium titanate (PZT) matrix transducer with an integrated receive ASIC, as a proof of concept for a miniature three-dimensional (3-D) transesophageal echocardiography (TEE) probe. It consists of an array of 9 ×12 piezoelectric elements mounted on the ASIC via an integration scheme that involves direct electrical connections between a bond-pad array on the ASIC and the transducer elements. The ASIC addresses the critical challenge of reducing cable count, and includes front-end amplifiers with adjustable gains and micro-beamformer circuits that locally process and combine echo signals received by the elements of each 3 ×3 subarray. Thus, an order-of-magnitude reduction in the number of receive channels is achieved. Dedicated circuit techniques are employed to meet the strict space and power constraints of TEE probes. The ASIC has been fabricated in a standard 0.18-μm CMOS process and consumes only 0.44 mW/channel. The prototype has been acoustically characterized in a water tank. The ASIC allows the array to be presteered across ±37° while achieving an overall dynamic range of 77 dB. Both the measured characteristics of the individual transducer elements and the performance of the ASIC are in good agreement with expectations, demonstrating the effectiveness of the proposed techniques.

  2. Study of startup conditions of a pulsed annular reactor

    International Nuclear Information System (INIS)

    Silva, Mario Augusto Bezerra da

    2003-10-01

    A new concept of reactor, which combines features of pulsed and stationary reactors, was proposed so as to produce intense neutronic fluxes. Such a reactor, known as VICHFPR (Very Intense Continuous High Flux Pulsed Reactor), consists of a subcritical core with an annular geometry and pulsed by a rotating reflector which acts as a reactivity modulator as it produces a short pulse (approximately equal to 1 ms) of high intensity, guiding the region near the pulser to super-prompt critical state. This dissertation intends to analyze the startup conditions of a Pulsed Annular Reactor. The evolution of the neutron pulse intensity is analyzed when the reactivity modulator is brought upwards according to a helicoidal path from its initial position (far away from the core), when the multiplication factor has a subcritical value, up to the final position (near the core), in which a super-prompt critical state is reached. Part of the analysis is based on the variation of neutron reflection, which is a uniform function of the exit and reflection angles between the core and the modulator. It must be emphasized that this work is an approximation of the real situation. As the initial and final reactor parameters are known, a programming code in Fortran is worked out to provide the multiplication factor and the flux intensity evolution. According to the results obtained with this code, the conditions under which the modulator must be lifted up during the startup are established. Basically, these conditions are related to the analysis of the rising and the rotation velocities, the reflector saving and the initial distance between the reactor and the modulator. The Pulsed Annular Reactor startup was divided into three stages. Because of its negative reactivity in the first two stages, the neutron multiplication is not large, while the last one, having a positive reactivity, shows an intense multiplication as is usually expected when handling pulsed systems. This last stage is quite

  3. A structural health monitoring system with ultrasonic MEMS transducers

    Science.gov (United States)

    Guldiken, Rasim O.; Onen, Onursal; Gul, Mustafa; Catbas, F. Necati

    2011-04-01

    In this paper, we will summarize our efforts on exploring guided acoustic waves generated by MEMS ultrasonic transducers enabling a non-destructive, ultra-low powered, wireless SHM system. State-of-the-art SHM systems employ bulk piezoelectric transducers. However, they are not environmentally benign (contain lead), not cost feasible for monitoring every bridge in the U.S., require significant power for operation, lack integration capability for wireless interrogation, need precise matching layers, and have only 25-50 percent fractional bandwidth, limiting the detection resolution. To alleviate most of these shortcomings, a low impedance MEMS transducer, called a capacitive micromachined ultrasonic transducer (CMUT), is explored.

  4. Calibration of Field II using a Convex Ultrasound Transducer

    DEFF Research Database (Denmark)

    Bæk, David; Jensen, Jørgen Arendt; Willatzen, Morten

    2010-01-01

    of the transducer. For such simulations to reflect actual measured intensities and pressure levels, the transducer impulse response is to be known. This work presents the results of combining a modified form of a 1D linear transducer model originally suggested by Willatzen with the Field II program to calibrate...... BK-Medical (Herlev, Denmark). As input waveform for the Field model we measured the output voltage of the research amplifier, which peak voltage was limited to 31 V to avoid too high non linear effects. We measured the hydrophone output from three transducer front elements by averaging 40 shoot...

  5. Transducers for Sound and Vibration - FEM Based Design

    DEFF Research Database (Denmark)

    Liu, Bin

    2001-01-01

    Design of transducers for measurement of vibration (piezoelectric accelerometers) and sound (condenser microphones) is a very labour intensive work. The design work is mostly based on experience and on simple analogies to electrical circuit design. Often a time consuming itterative loop is used......: Specification of the transducer, production of a physical prototype, measurements on the prototype, changed specification of the transducer etc. Furthermore are many transducers made based on customer requirements which also increases the amount of required design work. For these reasons there is a need...

  6. Smart concrete slabs with embedded tubular PZT transducers for damage detection

    Science.gov (United States)

    Gao, Weihang; Huo, Linsheng; Li, Hongnan; Song, Gangbing

    2018-02-01

    The objective of this study is to develop a new concept and methodology of smart concrete slab (SCS) with embedded tubular lead zirconate titanate transducer array for image based damage detection. Stress waves, as the detecting signals, are generated by the embedded tubular piezoceramic transducers in the SCS. Tubular piezoceramic transducers are used due to their capacity of generating radially uniform stress waves in a two-dimensional concrete slab (such as bridge decks and walls), increasing the monitoring range. A circular type delay-and-sum (DAS) imaging algorithm is developed to image the active acoustic sources based on the direct response received by each sensor. After the scattering signals from the damage are obtained by subtracting the baseline response of the concrete structures from those of the defective ones, the elliptical type DAS imaging algorithm is employed to process the scattering signals and reconstruct the image of the damage. Finally, two experiments, including active acoustic source monitoring and damage imaging for concrete structures, are carried out to illustrate and demonstrate the effectiveness of the proposed method.

  7. Design for a One-Gigawatt, Annular-Beam Klystron

    Energy Technology Data Exchange (ETDEWEB)

    Arfin, Bernard

    2001-01-23

    A one-gigawatt, annular beam klystron (ABK) is being developed by Los Alamos National Laboratory in collaboration with the Stanford Linear Accelerator Center (SLAC). The pulse length is 1 {micro}s, the pulse repetition frequency is 5 Hz, and the operating frequency is 1.3 GHz. The beam voltage and current are 800 kV and 4 kA. Since the electron beam parameters are considerably beyond the state-of the-art, an aggressive cathode and electron gun design is required. The magnetron injection gun (MIG) configuration was chosen over the standard Pierce geometry that is typically used in klystrons. The tube design, design issues, and status are presented.

  8. Damping of cylindrical structures subject to annular flow

    International Nuclear Information System (INIS)

    Hobson, D.E.; Dolding, M.

    1989-01-01

    In previous reports theoretical methods have been described for estimating the aerodynamic forces acting on cylinders vibrating laterally when surrounded by an annulus carrying high velocity gas. For a certain restricted set of geometries it is possible to predict whether a particular structure is stable or unstable and to determine the level of aerodynamic damping positive or negative due to the presence of the gas. This report describes experimental work which validates the computer program in which the theoretical methods are embodied; in particular the damping, inertial and decentralising forces acting on a cylinder in an annulus are measured and compared with theory over a range of frequencies from 0 to 25 Hz, and of Reynolds numbers from zero to 10 4 . In addition a summary of simple relationships is provided which can be used to provide credible initial estimates of both the positive and negative damping of cylinders in a range of annular geometries. (author)

  9. Design of an Annular Disc Subject to Thermomechanical Loading

    Directory of Open Access Journals (Sweden)

    Sergei Alexandrov

    2012-01-01

    Full Text Available Two solutions to design a thin annular disc of variable thickness subject to thermomechanical loading are proposed. It is assumed that the thickness of the disc is everywhere sufficiently small for the stresses to be averaged through the thickness. The state of stress is plane. The initiation of plastic yielding is controlled by Mises yield criterion. The design criterion for one of the solutions proposed requires that the distribution of stresses is uniform over the entire disc. In this case there is a relation between optimal values of the loading parameters at the final stage. The specific shape of the disc corresponds to each pair of such parameters. The other solution is obtained under the additional requirement that the distribution of strains is uniform. This solution exists for the disc of constant thickness at specific values of the loading parameters.

  10. Two-phase flow instabilities in a vertical annular channel

    Energy Technology Data Exchange (ETDEWEB)

    Babelli, I.; Nair, S.; Ishii, M. [Purdue Univ., West Lafayette, IN (United States)

    1995-09-01

    An experimental test facility was built to study two-phase flow instabilities in vertical annular channel with emphasis on downward flow under low pressure and low flow conditions. The specific geometry of the test section is similar to the fuel-target sub-channel of the Savannah River Site (SRS) Mark 22 fuel assembly. Critical Heat Flux (CHF) was observed following flow excursion and flow reversal in the test section. Density wave instability was not recorded in this series of experimental runs. The results of this experimental study show that flow excursion is the dominant instability mode under low flow, low pressure, and down flow conditions. The onset of instability data are plotted on the subcooling-Zuber (phase change) numbers stability plane.

  11. Annular billiard dynamics in a circularly polarized strong laser field

    Science.gov (United States)

    Kamor, A.; Mauger, F.; Chandre, C.; Uzer, T.

    2012-01-01

    We analyze the dynamics of a valence electron of the buckminsterfullerene molecule (C60) subjected to a circularly polarized laser field by modeling it with the motion of a classical particle in an annular billiard. We show that the phase space of the billiard model gives rise to three distinct trajectories: “whispering gallery orbits,” which hit only the outer billiard wall; “daisy orbits,” which hit both billiard walls (while rotating solely clockwise or counterclockwise for all time); and orbits that only visit the downfield part of the billiard, as measured relative to the laser term. These trajectories, in general, maintain their distinct features, even as the intensity is increased from 1010 to 1014Wcm-2. We attribute this robust separation of phase space to the existence of twistless tori.

  12. Annular dark field transmission electron microscopy for protein structure determination.

    Science.gov (United States)

    Koeck, Philip J B

    2016-02-01

    Recently annular dark field (ADF) transmission electron microscopy (TEM) has been advocated as a means of recording images of biological specimens with better signal to noise ratio (SNR) than regular bright field images. I investigate whether and how such images could be used to determine the three-dimensional structure of proteins given that an ADF aperture with a suitable pass-band can be manufactured and used in practice. I develop an approximate theory of ADF-TEM image formation for weak amplitude and phase objects and test this theory using computer simulations. I also test whether these simulated images can be used to calculate a three-dimensional model of the protein using standard software and discuss problems and possible ways to overcome these. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Annular suspension and pointing system with controlled DC electromagnets

    Science.gov (United States)

    Vu, Josephine Lynn; Tam, Kwok Hung

    1993-01-01

    The Annular Suspension and Pointing System (ASPS) developed by the Flight System division of Sperry Corporation is a six-degree of freedom payload pointing system designed for use with the space shuttle. This magnetic suspension and pointing system provides precise controlled pointing in six-degrees of freedom, isolation of payload-carrier disturbances, and end mount controlled pointing. Those are great advantages over the traditional mechanical joints for space applications. In this design, we first analyzed the assumed model of the single degree ASPS bearing actuator and obtained the plant dynamics equations. By linearizing the plant dynamics equations, we designed the cascade and feedback compensators such that a stable and satisfied result was obtained. The specified feedback compensator was computer simulated with the nonlinearized plant dynamics equations. The results indicated that an unstable output occurred. In other words, the designed feedback compensator failed. The failure of the design is due to the Taylor's series expansion not converging.

  14. Numerical simulation of random stresses on an annular turbulent flow

    International Nuclear Information System (INIS)

    Marti-Moreno, Marta

    2000-01-01

    The flow along a circular cylinder may induce structural vibrations. For the predictive analysis of such vibrations, the turbulent forcing spectrum needs to be characterized. The aim of this work is to study the turbulent fluid forces acting on a single tube in axial flow. More precisely we have performed numerical simulations of an annular flow. These simulations were carried out on a cylindrical staggered mesh by a finite difference method. We consider turbulent flow with Reynolds number up to 10 6 . The Large Eddy Simulation Method has been used. A survey of existent experiments showed that hydraulic diameter acts as an important parameter. We first showed the accuracy of the numerical code by reproducing the experiments of Mulcahy. The agreement between pressure spectra from computations and from experiments is good. Then, we applied this code to simulate new numerical experiments varying the hydraulic diameter and the flow velocity. (author) [fr

  15. Mechanistic model of the inverted annular film boiling

    International Nuclear Information System (INIS)

    Seok, Ho; Chang, Soon Heung

    1989-01-01

    An analytical model is developed to predict the heat transfer coefficient and the friction factor in the inverted annular film boiling. The developed model is based on two-fluid mass, momentum and energy balance equations and a theoretical velocity profile. The predictions of the proposed model are compared with the experimental data and the well-established correlations. For the heat transfer coefficient, they agree with the experimental data and are more promising than those of Bromely and Berenson correlations. The present model also accounts the effects of the mass flux and subcooling on the heat transfer. The friction factor predictions agree qualitatively with the experimental measurements, while some cases show a similar behavior with those of the post-CHF dispersed flow obtained from Beattie's correlation

  16. Annular elastolytic giant cell granuloma of conjunctiva: A case report

    Directory of Open Access Journals (Sweden)

    Karabi Konar

    2014-01-01

    Full Text Available Annular elastolytic giant cell granuloma is a condition characterized histologically by damaged elastic fibers associated with preponderance of giant cells along with absence of necrobiosis, lipid, mucin, and pallisading granuloma. It usually occurs on sun-damaged skin and hence the previous name actinic granuloma. A similar process occurs on the conjunctiva. Over the past three decades only four cases of conjunctival actinic granuloma have been documented. All the previous patients were females with lesions in nasal or temporal bulbar conjunctiva varying 2-3 mm in size. We report a male patient aged 70 years presenting with a 14 mm × 7 mm fleshy mass on right lower bulbar conjunctiva. Clinical differential diagnoses were lymphoma, squamous cell carcinoma in situ and amyloidosis. Surgical excision followed by histopathology confirmed it to be a case of actinic granuloma. This is the first case of isolated conjunctival actinic granuloma of such a large size reported from India.

  17. Development of annular targets for 99MO production-1999

    International Nuclear Information System (INIS)

    Conner, C.; Lewandowski, E. F.; Snelgrove, J. L.; Liberatore, M. W.; Walker, D. E.; Wiencek, T. C.; McGann, D. J.; Hofman, G. L.; Vandegrift, G. F.

    1999-01-01

    The new annular target performed well during irradiation. The target is inexpensive and provides good heat transfer during irradiation. Based on these and previous tests, we conclude that targets with zirconium tubes and either nickel-plated or zinc-plated foils work well. We proved that we could use aluminum target tubes, which are much cheaper and easier to work with than the zirconium tubes. In aluminum target tubes nickel-plated fission-recoil barriers work well and prevent bonding of the foil to the new target tubes during irradiation. Also, zinc-plated and aluminum-foil barriers appear promising in anodized aluminum tubes. Additional tests are anticipated to address such issues as fission-recoil barrier thickness and uranium foil composition. Overall, however, the target was successful and will provide an inexpensive, efficient way to irradiate LEU metal foil for the production of 99 Mo

  18. Interfacial shear modeling in two-phase annular flow

    International Nuclear Information System (INIS)

    Kumar, R.; Edwards, D.P.

    1996-07-01

    A new interfacial shear stress model called the law of the interface model, based on the law of the wall approach in turbulent flows, has been developed and locally applied in a fully developed, adiabatic, two-phase annular flow in a duct. Numerical results have been obtained using this model in conjunction with other models available in the literature that are required for the closure of the continuity and momentum equations. These results have been compared with droplet velocity data (using laser Doppler velocimetry and hot film anemometry), void fraction data (using gamma densitometry) and pressure drop data obtained in a R-134A refrigerant test facility. Droplet velocity results match the experimental data well, however, the prediction of the void fraction is less accurate. The poor prediction of void fraction, especially for the low void fraction cases, appears to be due to the lack of a good mechanistic model for entrainment

  19. Numerical investigation on the recirculation in annular jet pumps

    International Nuclear Information System (INIS)

    Xiao, Longzhou; Long, Xinping; Zeng, Qinglong; Yang, Xuelong; Li, Xiaohong

    2013-01-01

    The flow within the annular jet pump (AJP), in some degree, resembles the annular wall jet developing in a pipe with great axial pressure gradient. In some working conditions, there exists the backflow near the centerline. However this differs from the case in a center jet pump (CJP) that the recirculation emerges near the inner wall of the throat. The recirculation in AJP affects a lot to its performance, especially when AJP is utilized to convey something alive, such as fish. This paper aims to numerically study the impact of two parameters, the flow ratio M and the area ratio A, on the location, size and formation of the recirculation in AJP. After being validated by the experimental results, the RNG k-ε turbulent model was adopted. It is found that: (1) As M increases, the width and height of the recirculation in AJP decreases, and the separation point of the recirculation shifts gradually far away from the nozzle exit while the reattachment point slightly moves; (2) As A becomes larger, the width and height of the recirculation enlarged, with M keeping constant; (3) For AJP with constant A, the recirculation emerges when M declines to a critical value, and the value varies linearly with A; (4) The Craya-Curtet number C t and the momentum ratio J, which take A and M into whole consideration, are also feasible in describing the disappearance of the recirculation. However the critical value of C t and J are different from that discovered in CJP. The critical C t increases with decreasing A and the critical momentum ratio J c experiences a linear relationship with A.

  20. Sausage and kink oscillations in incompressible annular magnetic cylinders

    Science.gov (United States)

    Carter, B. K.; Erdélyi, R.

    2007-11-01

    Aims:The propagation of MHD waves in a structured magnetic flux tube embedded within a straight magnetic environment is studied analytically. The motivation for this analysis comes from the observations of damped loop oscillations indicating the possibility that only part of the loop is homogeneous in the radial direction and from the observation of two simultaneous waves with different speeds in the same magnetic loop in the solar atmosphere. Methods: The general dispersion relation of longitudinal wave propagation is derived for a flux tube configuration consisting of a core, annulus and external region each with straight distinct magnetic field. Modes of oscillation are examined from the general dispersion relation that is suitable for obtaining information not just on oscillations but also on some instability properties of this complex tube structure. Specific attention is given to the modification of the phase speeds and oscillation periods caused by the annulus structure, compared to a single monolithic tube. Results: It is shown that two purely surface modes arise. The relative change in periods due to the additional annulus layer is shown to be rather significant (up to 20% in some cases). In particular we found that in photospheric type annular tubes, periods are less than their counterparts in a monolithic loop while for a dense flux tube in the majority of cases the period was greater than the period of the counterpart monolithic flux tube. Both short and long wavelength approximations are considered for both the symmetrical (sausage) and kink modes. Conclusions: Annular structuring of a magnetic flux tube will reduce or increase periods of the allowed oscillations depending on the type of flux tube considered (either as a magnetic or as a density enhancement). The results are relevant to further our knowledge of solar magneto-seismology. In particular, the obtained results for the kink oscillations may be applicable from photosphere to corona, while the

  1. Thermal-to-visible transducer (TVT) for thermal-IR imaging

    Science.gov (United States)

    Flusberg, Allen; Swartz, Stephen; Huff, Michael; Gross, Steven

    2008-04-01

    We have been developing a novel thermal-to-visible transducer (TVT), an uncooled thermal-IR imager that is based on a Fabry-Perot Interferometer (FPI). The FPI-based IR imager can convert a thermal-IR image to a video electronic image. IR radiation that is emitted by an object in the scene is imaged onto an IR-absorbing material that is located within an FPI. Temperature variations generated by the spatial variations in the IR image intensity cause variations in optical thickness, modulating the reflectivity seen by a probe laser beam. The reflected probe is imaged onto a visible array, producing a visible image of the IR scene. This technology can provide low-cost IR cameras with excellent sensitivity, low power consumption, and the potential for self-registered fusion of thermal-IR and visible images. We will describe characteristics of requisite pixelated arrays that we have fabricated.

  2. Tomographic array

    International Nuclear Information System (INIS)

    1976-01-01

    The configuration of a tomographic array in which the object can rotate about its axis is described. The X-ray detector is a cylindrical screen perpendicular to the axis of rotation. The X-ray source has a line-shaped focus coinciding with the axis of rotation. The beam is fan-shaped with one side of this fan lying along the axis of rotation. The detector screen is placed inside an X-ray image multiplier tube

  3. Tomographic array

    International Nuclear Information System (INIS)

    1976-01-01

    A tomographic array with the following characteristics is described. An X-ray screen serving as detector is placed before a photomultiplier tube which itself is placed in front of a television camera connected to a set of image processors. The detector is concave towards the source and is replacable. Different images of the object are obtained simultaneously. Optical fibers and lenses are used for transmission within the system

  4. HOLOGRAPHIC VISUALIZATION OF CYLINDRICAL PIEZOCERAMIC TRANSDUCERS VIBRATIONS

    Directory of Open Access Journals (Sweden)

    R. Vasiliauskas

    2013-01-01

    Full Text Available The piezomaterial used in cylindrical piezoceramic transducers vibrations requiring high precision displacements indicates that accuracy depends on design and technological factors. The analyzed criteria have made possible to choose the piezomaterial for optimal mechatronic system having a maximal displacement. The experimental investigation of precision vibrosystems by means of 3D holographic visualization enables one to obtain appreciably larger amount of information about the vibrating surface in comparison with traditional methods. On the basis of the developed methodology of analyzing the experimental data derived from 3D holographic visualization and by using the experimental holography stand, we have obtained results making it possible to optimize the design of operation of the piezoceramic mechatronic system or its separate elements.

  5. Development of piezoelectric composites for transducers

    Science.gov (United States)

    Safari, A.

    1994-07-01

    For the past decade and a half, many different types of piezoelectric ceramic-polymer composites have been developed intended for transducer applications. These diphasic composites are prepared from non-active polymer, such as epoxy, and piezoelectric ceramic, such as PZT, in the form of filler powders, elongated fibers, multilayer and more complex three-dimensional structures. For the last four years, most of the efforts have been given to producing large area and fine scale PZT fiber composites. In this paper, processing of piezoelectric ceramic-polymer composites with various connectivity patterns are reviewed. Development of fine scale piezoelectric composites by lost mold, injection molding and the relic method are described. Research activities of different groups for preparing large area piezocomposites for hydrophone and actuator applications are briefly reviewed. Initial development of electrostrictive ceramics and composites are also

  6. Modeling piezoelectric ultrasonic transducers for physiotherapy

    International Nuclear Information System (INIS)

    Iglesias, E.; Frutos, J. de; Montero de Espinosa, F.

    2015-01-01

    Applications of ultrasound are well known in medical and aesthetic skin and subcutaneous fatty tissue mobilization treatments. The basic transducer used consists of a piezoelectric disk adhered to a metal delay line in capsule shape. The capsule design is critical since the two bonded elements have vibration modes which can cause very inefficient designs and vibration distributions very irregular if they are not properly studied and utilized. This must be known to avoid distributions of heat and sound pressure that could be ineffective or harmful. In this paper, using Finite Element Method and laser interferometric vibrational analysis, it has reached a piston-type solution that allows properly implement sound pressure vibration dose. (Author)

  7. Design optimization of embedded ultrasonic transducers for concrete structures assessment.

    Science.gov (United States)

    Dumoulin, Cédric; Deraemaeker, Arnaud

    2017-08-01

    In the last decades, the field of structural health monitoring and damage detection has been intensively explored. Active vibration techniques allow to excite structures at high frequency vibrations which are sensitive to small damage. Piezoelectric PZT transducers are perfect candidates for such testing due to their small size, low cost and large bandwidth. Current ultrasonic systems are based on external piezoelectric transducers which need to be placed on two faces of the concrete specimen. The limited accessibility of in-service structures makes such an arrangement often impractical. An alternative is to embed permanently low-cost transducers inside the structure. Such types of transducers have been applied successfully for the in-situ estimation of the P-wave velocity in fresh concrete, and for crack monitoring. Up to now, the design of such transducers was essentially based on trial and error, or in a few cases, on the limitation of the acoustic impedance mismatch between the PZT and concrete. In the present study, we explore the working principles of embedded piezoelectric transducers which are found to be significantly different from external transducers. One of the major challenges concerning embedded transducers is to produce very low cost transducers. We show that a practical way to achieve this imperative is to consider the radial mode of actuation of bulk PZT elements. This is done by developing a simple finite element model of a piezoelectric transducer embedded in an infinite medium. The model is coupled with a multi-objective genetic algorithm which is used to design specific ultrasonic embedded transducers both for hard and fresh concrete monitoring. The results show the efficiency of the approach and a few designs are proposed which are optimal for hard concrete, fresh concrete, or both, in a given frequency band of interest. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Dual-Element Transducer with Phase-Inversion for Wide Depth of Field in High-Frequency Ultrasound Imaging

    Directory of Open Access Journals (Sweden)

    Jong Seob Jeong

    2014-08-01

    Full Text Available In high frequency ultrasound imaging (HFUI, the quality of focusing is deeply related to the length of the depth of field (DOF. In this paper, a phase-inversion technique implemented by a dual-element transducer is proposed to enlarge the DOF. The performance of the proposed method was numerically demonstrated by using the ultrasound simulation program called Field-II. A simulated dual-element transducer was composed of a disc- and an annular-type elements, and its aperture was concavely shaped to have a confocal point at 6 mm. The area of each element was identical in order to provide same intensity at the focal point. The outer diameters of the inner and the outer elements were 2.1 mm and 3 mm, respectively. The center frequency of each element was 40 MHz and the f-number (focal depth/aperture size was two. When two input signals with 0° and 180° phases were applied to inner and outer elements simultaneously, a multi-focal zone was generated in the axial direction. The total −6 dB DOF, i.e., sum of two −6 dB DOFs in the near and far field lobes, was 40% longer than that of the conventional single element transducer. The signal to noise ratio (SNR was increased by about two times, especially in the far field. The point and cyst phantom simulation were conducted and their results were identical to that of the beam pattern simulation. Thus, the proposed scheme may be a potential method to improve the DOF and SNR in HFUI.

  9. Research on Annular Frictional Pressure Loss of Hydraulic-Fracturing in Buckling Coiled Tubing

    Science.gov (United States)

    Liu, Bin; Cai, Meng; Li, Junliang; Xu, Yongquan; Wang, Peng

    2018-01-01

    Compared with conventional hydraulic fracturing, coiled tubing (CT) annular delivery sand fracturing technology is a new method to enhance the recovery ratio of low permeability reservoir. Friction pressure loss through CT has been a concern in fracturing. The small diameter of CT limits the cross-sectional area open to flow, therefore, to meet large discharge capacity, annular delivery sand technology has been gradually developed in oilfield. Friction pressure is useful for determining the required pump horsepower and fracturing construction design programs. Coiled tubing can buckle when the axial compressive load acting on the tubing is greater than critical buckling load, then the geometry shape of annular will change. Annular friction pressure loss elevates dramatically with increasing of discharge capacity, especially eccentricity and CT buckling. Despite the frequency occurrence of CT buckling in oilfield operations, traditionally annular flow frictional pressure loss considered concentric and eccentric annuli, not discussing the effects of for discharge capacity and sand ratio varying degree of CT buckling. The measured data shows that the factors mentioned above cannot be ignored in the prediction of annular pressure loss. It is necessary to carry out analysis of annulus flow pressure drop loss in coiled tubing annular with the methods of theoretical analysis and numerical simulation. Coiled tubing buckling has great influence on pressure loss of fracturing fluid. Therefore, the correlations have been developed for turbulent flow of Newtonian fluids and Two-phase flow (sand-liquid), and that improve the friction pressure loss estimation in coiled tubing operations involving a considerable level of buckling. Quartz sand evidently increases pressure loss in buckling annular, rising as high as 40%-60% more than fresh water. Meanwhile, annulus flow wetted perimeter increases with decreasing helical buckling pitch of coiled tubing, therefore, the annulus flow

  10. Cellular and Extracellular Matrix Basis for Heterogeneity in Mitral Annular Contraction

    Science.gov (United States)

    Stephens, Elizabeth H.; Fahrenholtz, Monica M.; Connell, Patrick S.; Timek, Tomasz A.; Daughters, George T.; Kuo, Joyce J.; Patton, Aaron M.; Ingels, Neil B.; Miller, D. Craig; Grande-Allen, K. Jane

    2015-01-01

    Purpose Regional heterogeneity in mitral annular contraction, which is generally ascribed to the fibrous vs. muscular annular composition, ensures proper leaflet motion and timing of coaptation. It is unknown whether the fibroblast-like cells in the annulus modulate this heterogeneity, even though valvular interstitial cells (VICs) can be mechanically “activated.” Methods Fourteen sheep underwent implantation of radiopaque markers around the mitral annulus defining four segments: septal (SEPT), lateral (LAT), and anterior (ANT-C) and posterior (POST-C) commissures. Segmental annular contraction was calculated using biplane videofluoroscopy. Immunohistochemistry of annular cross sections assessed regional matrix content, matrix turnover, and cell phenotype. Micropipette aspiration measured the Young's modulus of the leaflets adjacent to the myocardial border. Results Whereas SEPT contained more collagen I and III, LAT demonstrated more collagen and elastin turnover as shown by greater decorin, lysyl oxidase, and matrix metalloprotease (MMP)-13 and smooth muscle alpha-actin (SMaA). This greater matrix turnover paralleled greater annular contraction in LAT vs. SEPT (22.5% vs. 4.1%). Similarly, POST-C had more SMaA and MMP13 than ANT-C, consistent with greater annular contraction in POST-C (18.8% vs. 11.1%). Interestingly, POST-C had the greatest effective modulus, significantly higher than LAT. Conclusions These data suggest that matrix turnover by activated VICs relates to annular motion heterogeneity, maintains steady-state mechanical properties in the annulus, and could be a therapeutic target when annular motion is impaired. Conversely, alterations in this heterogeneous annular contraction, whether through disease or secondary to ring annuloplasty, could disrupt this normal pattern of cell-mediated matrix remodeling and further adversely impact mitral valve function. PMID:26195991

  11. Evaluation of a novel therapeutic focused ultrasound transducer based on Fermat’s spiral

    Science.gov (United States)

    Ramaekers, P.; de Greef, M.; Berriet, R.; Moonen, C. T. W.; Ries, M.

    2017-06-01

    The purpose of this study was to evaluate a novel phased array transducer design rule for therapeutic focused ultrasound applications. This design rule uses the discretized Fermat’s spiral to determine the positioning of the transducer elements for a given number of elements and f-number. Using this principle, three variations of Fermat’s spiral were generated, aimed at (1) grating lobe minimization, (2) side lobe minimization, and (3) an optimized element packing efficiency. For each spiral, sparse layouts using identical circular elements and fully populated layouts based on additional Voronoi tessellation were evaluated numerically. Evaluation criteria included the element size distribution, beam steering capabilities, focal plane pressure distribution, prefocal pressure distribution, and practical considerations. Finally, one Voronoi-tessellated design with a focal length and aperture diameter of 16 cm and a natural frequency of 1.3 MHz was evaluated experimentally through hydrophone measurements. The numerical evaluation showed that while sparse arrays possess superior beam steering capabilities for a given number of elements, the focal point quality and prefocal pressure distribution is substantially more favorable when using the Voronoi-tessellated designs. Beam steering was shown to be feasible with the tessellated designs for lateral deflections up to 10 mm and axial deflections up to 20 mm. The experimental evaluation showed that such a transducer is capable of inducing 40.00 MPa rarefactional and 237.50 MPa compressional peak pressure levels at 800 W instantaneous acoustic output power under free-field conditions, making the system potentially relevant for thermal ablation therapy, histotripsy applications, and shockwave-enhanced heating.

  12. Respiratory Belt Transducer Constructed Using a Singing Greeting Card Beeper

    Science.gov (United States)

    Bhaskar, Anand; Subramani, Selvam; Ojha, Rajdeep

    2013-01-01

    An article by Belusic and Zupancic described the construction of a finger pulse sensor using a singing greeting card beeper. These authors felt that this beeper made of piezoelectric material could be easily modified to function as a respiratory belt transducer to monitor respiratory movements. Commercially available respiratory belt transducers,…

  13. Dynamics Characterisation of Cymbal Transducers for Power Ultrasonics Applications

    Science.gov (United States)

    Feeney, Andrew; Bejarano, Fernando; Lucas, Margaret

    A class V cymbal flextensional transducer is composed of a piezoceramic disc sandwiched between two cymbal-shaped shell end-caps. Depending on the type of piezoceramic, there exists a maximum voltage that can be reached without depolarisation, but also, at higher voltage levels, amplitude saturation can occur. In addition, there is a restriction imposed by the mechanical strength of the bonding agent. The effects of input voltage level on the vibration response of two cymbal transducers are studied. The first cymbal transducer has a standard configuration of end-caps bonded to a piezoceramic disc, whereas the second cymbal transducer is a modified design which includes a metal ring to improve the mechanical coupling with the end-caps, to enable the transducer to operate at higher voltages, thereby generating higher displacement amplitudes. This would allow the transducer to be suitable for power ultrasonics applications. Furthermore, the input voltages to each transducer are increased incrementally to determine the linearity in the dynamic responses. Through a combination of numerical modelling and experiments, it is shown how the improved mechanical coupling in the modified cymbal transducer allows higher vibration amplitudes to be reached.

  14. Top-down tree transducers with regular look-ahead

    NARCIS (Netherlands)

    Engelfriet, Joost

    1977-01-01

    Top-down tree transducers with regular look-ahead are introduced. It is shown how these can be decomposed and composed, and how this leads to closure properties of surface sets and tree transformation languages. Particular attention is paid to deterministic tree transducers.

  15. A method for determining losses in magnetostrictive transducers

    Science.gov (United States)

    Krysin, V. N.; Ketlerov, A. S.

    A method for estimating energy losses in magnetostrictive transducers is described. It is shown that domain remagnetization is responsible for the greatest energy loss in magnetostrictive transducers. Energy losses associated with Foucault currents and Joule heat are an order of magnitude less.

  16. [The manufacture of the pressure transducer for medical Solos Insufflator].

    Science.gov (United States)

    Huang, X

    2001-07-01

    A 0-10 Kpa pressure transducer and its circuit are presented in the paper, which can be used as a substitute for the integrated pressure transducer in medical Solos Insufflator and can be used too in other devices and equipments.

  17. Broadband tonpilz underwater acoustic transducers based on multimode optimization

    DEFF Research Database (Denmark)

    Yao, Qingshan; Jensen, Leif Bjørnø

    1997-01-01

    Head flapping has often been considered to be deleterious for obtaining a tonpilz transducer with broadband, high power performance. In the present work, broadband, high power tonpilz transducers have been designed using the finite element (FE) method. Optimized vibrational modes including the fl...

  18. A rotary ultrasonic motor using bending vibration transducers.

    Science.gov (United States)

    Liu, Yingxiang; Chen, Weishan; Liu, Junkao; Shi, Shengjun

    2010-10-01

    A rotary ultrasonic motor using bending vibration transducers is proposed. In each transducer, two orthogonal bending vibrations are superimposed and an elliptical trajectory is generated at the driving foot. Typical output of the prototype is a no-load speed of 58 rpm and maximum torque of 9·5 Nm under an exciting voltage of 200 V(rms).

  19. Transducer hygiene: comparison of procedures for decontamination of ultrasound transducers and their use in clinical practice.

    Science.gov (United States)

    Häggström, Mikael; Spira, Jack; Edelstam, Greta

    2015-02-01

    To determine whether current hygiene practices are appropriate during sonographic examinations. Five major hospitals in Sweden were investigated with a survey. At each hospital, the departments corresponding to the main types of sonographic examination were chosen. Personnel who were responsible for or acquainted with the local hygiene procedures completed a standardardized questionnaire. The surveys were completed by 25 departments, where the total number of sonographic examinations was approximately 20,000 per month. For transvaginal and transrectal sonographic examinations, the most common method for decontamination of the transducer was barrier protection during the procedure followed by cleansing with alcohol. Latex was the predominant cover material, but one department used polyethylene gloves, and another department used nitrile gloves. Both of these involved transvaginal ultrasonography. In transcutaneous examinations, all hospitals were using alcohol and paper or cloth for decontamination at a minimum. Transesophageal examinations were carried out without barrier protection, and decontamination was performed with an alkylating substance. The hygiene practices appear to be appropriate at most hospitals, but there is a prevalence of transducer cover materials of unacceptable permeability, as well as use of gloves on transducers despite insufficient evidence of safety. © 2015 Wiley Periodicals, Inc.

  20. Burnout in the boiling of water and freon-113 on tubes with annular fins

    International Nuclear Information System (INIS)

    Rubin, I.R.; Pul'kin, I.N.; Roizen, L.I.

    1986-01-01

    This paper presents the results of numerical calculations of burnout heat flux associated with the boiling of Freon-113 and water on an annular fin of constant thickness which have been approximated by simple analytical relations. These are used to calculate the critical burnout parameters of tubes with an annular fin assembly. The calculated data may be used for the analysis of tubes with an annular fin assembly over a wide range of variation of the thermophysical properties of the material and geometrical parameters of the fin assembly

  1. Simple correlation equations for optimum design of annular fins with uniform thickness

    International Nuclear Information System (INIS)

    Arslanturk, Cihat

    2005-01-01

    Simple correlation equations for optimum design of annular fins with uniform cross section are obtained in the present work. The fin volume is fixed to obtain the dimensionless geometrical parameters of the fin with maximum heat transfer rates. The optimum radii ratio of an annular fin which maximizes the heat transfer rate has been found as a function of Biot number and the fin volume. The data from the present solutions is correlated for a suitable range of Biot number and the fin volume. The simple correlation equations presented in this work can assist for thermal design engineers for optimum design of annular fins of uniform thickness

  2. Fluid-structure coupling between a vibrating cylinder and a narrow annular flow

    International Nuclear Information System (INIS)

    Perotin, L.

    1994-01-01

    This paper presents an analytical investigation of the fluidelastic coupling between an axial annular flow and a flexible vibrating axisymmetrical structure. The model presented is suited to single-phase, incompressible, viscous fluids and to annular flows of variable cross-section, axially symmetrical when the structure is motionless.An experimental validation of this model is presented at the end of the paper: the results obtained with the numerical model are compared with experimental data for an oscillating cylinder free to vibrate under the effect of a variable-cross-section annular flow. ((orig.))

  3. Automated phased array ultrasonic inspection system for rail wheel sets

    International Nuclear Information System (INIS)

    Grosser, Paul; Weiland, M.G.

    2013-01-01

    This paper covers the design, system automation, calibration and validation of an automated ultrasonic system for the inspection of new and in service wheel set assemblies from diesel-electric locomotives and gondola cars. This system uses Phased Array (PA) transducers for flaw detection and Electro-Magnetic Acoustic Transducers (EMAT) for the measurement of residual stress. The system collects, analyses, evaluates and categorizes the wheel sets automatically. This data is archived for future comparison and trending. It is also available for export to a portal lathe for increased efficiency and accuracy of machining, therefore allowing prolonged wheel life.

  4. Reliable strain measurement in transistor arrays by robust scanning transmission electron microscopy

    Directory of Open Access Journals (Sweden)

    Suhyun Kim

    2013-09-01

    Full Text Available Accurate measurement of the strain field in the channels of transistor arrays is critical for strain engineering in modern electronic devices. We applied atomic-resolution high-angle annular dark-field scanning transmission electron microscopy to quantitative measurement of the strain field in transistor arrays. The quantitative strain profile over 20 transistors was obtained with high reliability and a precision of 0.1%. The strain field was found to form homogeneously in the channels of the transistor arrays. Furthermore, strain relaxation due to the thin foil effect was quantitatively investigated for thicknesses of 35 to 275 nm.

  5. Methods and analysis of processing signals of incremental optoelectronic transducer.

    Science.gov (United States)

    Szcześniak, Adam; Szcześniak, Zbigniew

    2009-09-01

    This article is a presentation of designed methods which interpolate signals from the optoelectronic transducer. This enables a way to distinguish the motion direction of the optoelectronic transducer and also to increase its accuracy. In this article methods based on logic functions, logic functions and RC circuits, phase processing were analyzed. In methods which are based on processing logic functions of transducer's signals there is a possibility of two times and four times increase in the transducer glass scale. The presented method of generating and processing sine signals with 18 degrees of the shift enables the reception of square signals with five times higher frequency compared to the basic signals. This method is universal and it can be used to the different scale of frequency multiplication of the optoelectronic transducer. The simulations of the methods were performed by using the MATLAB-SIMULINK software.

  6. Miniaturized ultrasound imaging probes enabled by CMUT arrays with integrated frontend electronic circuits.

    Science.gov (United States)

    Khuri-Yakub, B T; Oralkan, Omer; Nikoozadeh, Amin; Wygant, Ira O; Zhuang, Steve; Gencel, Mustafa; Choe, Jung Woo; Stephens, Douglas N; de la Rama, Alan; Chen, Peter; Lin, Feng; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai; Shivkumar, Kalyanam; Mahajan, Aman; Seo, Chi Hyung; O'Donnell, Matthew; Truong, Uyen; Sahn, David J

    2010-01-01

    Capacitive micromachined ultrasonic transducer (CMUT) arrays are conveniently integrated with frontend integrated circuits either monolithically or in a hybrid multichip form. This integration helps with reducing the number of active data processing channels for 2D arrays. This approach also preserves the signal integrity for arrays with small elements. Therefore CMUT arrays integrated with electronic circuits are most suitable to implement miniaturized probes required for many intravascular, intracardiac, and endoscopic applications. This paper presents examples of miniaturized CMUT probes utilizing 1D, 2D, and ring arrays with integrated electronics.

  7. 2D array based on fermat spiral

    Science.gov (United States)

    Martínez, O.; Martín, C. J.; Godoy, G.; Ullate, L. G.

    2010-01-01

    The main challenge faced by 3D ultrasonic imaging with 2D array transducer is the large number of elements required to achieve an acceptable level of quality in the images. Therefore, the optimization of the array layout to reduce the number of active elements in the aperture has been a research topic in the last years. Nowadays, CMUT array technology has made viable the production of 2D arrays with larger flexibility on elements size, shape and position. This is opening new options in 2D array design, allowing to revise as viable alternatives others layouts that had been studied in the past, like circular and Archimedes spiral layout. In this work the problem of designing an imaging system array with a diameter of 60 λ and a limited number of elements using the Fermat spiral layout has been studied. This study has been done for two different numbers of electronic channels (N = 128 and N = 256). As summary, a general discussion of the results and the most interesting cases are presented.

  8. Comparison between temperature distributions of an annular fuel rod of circular cross-section and of a hemoglobin shaped cross-section rod for PWR reactors in steady state conditions

    International Nuclear Information System (INIS)

    Oliveira, Maria Vitória A. de; Alvim, Antônio Carlos Marques

    2017-01-01

    The objective of this work is to make a comparison between the temperature distributions of an annular fuel rod of circular cross-section and a hemoglobin shaped cross-section for PWR reactors in steady state conditions. The motivation for this article is due to the fact that the symmetric form of the red globules particles allows the O 2 gases to penetrate the center of the cell homogeneously and quickly. The diffusion equation of gases in any environment is very similar to the heat diffusion equation: Diffusion - Fick's Law; Heat Flow - Fourier; where, the temperature (T) replaces the concentration (c). In previous works the comparison between the shape of solid fuel rods with circular section, and a with hemoglobin-shaped cross-section has proved that this new format optimizes the heat transfer, decreasing the thermal resistance between the center of the UO 2 pellets and the clad. With this, a significant increase in the specific power of the reactor was made possible (more precisely a 23% increase). Currently, the advantages of annular fuel rods are being studied and recent works have shown that 12 x 12 arrays of annular fuel rods perform better, increasing the specific power of the reactor by at least 20% in relation to solid fuel rods, without affecting the safety of the reactor. Our proposal is analyzing the temperature distribution in annular fuel rods with cross sections with red blood cell shape and compare with the theoretical results of the annular fuel rods of circular cross section, initially in steady state. (author)

  9. Comparison between temperature distributions of an annular fuel rod of circular cross-section and of a hemoglobin shaped cross-section rod for PWR reactors in steady state conditions

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Maria Vitória A. de; Alvim, Antônio Carlos Marques, E-mail: moliveira@con.ufrj.br, E-mail: alvim@nuclear.ufrj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2017-07-01

    The objective of this work is to make a comparison between the temperature distributions of an annular fuel rod of circular cross-section and a hemoglobin shaped cross-section for PWR reactors in steady state conditions. The motivation for this article is due to the fact that the symmetric form of the red globules particles allows the O{sub 2} gases to penetrate the center of the cell homogeneously and quickly. The diffusion equation of gases in any environment is very similar to the heat diffusion equation: Diffusion - Fick's Law; Heat Flow - Fourier; where, the temperature (T) replaces the concentration (c). In previous works the comparison between the shape of solid fuel rods with circular section, and a with hemoglobin-shaped cross-section has proved that this new format optimizes the heat transfer, decreasing the thermal resistance between the center of the UO{sub 2} pellets and the clad. With this, a significant increase in the specific power of the reactor was made possible (more precisely a 23% increase). Currently, the advantages of annular fuel rods are being studied and recent works have shown that 12 x 12 arrays of annular fuel rods perform better, increasing the specific power of the reactor by at least 20% in relation to solid fuel rods, without affecting the safety of the reactor. Our proposal is analyzing the temperature distribution in annular fuel rods with cross sections with red blood cell shape and compare with the theoretical results of the annular fuel rods of circular cross section, initially in steady state. (author)

  10. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area....... This study evaluates the authors' clinical experience with Top Hat supra-annular aortic valve size selection, and the technical aspects of implantation. METHODS: Between January 1999 and October 2005, a total of 251 consecutive patients underwent 252 aortic valve replacements with Top Hat supra...... required unplanned coronary bypass, and 30-day mortality was 2.0% (5/251), indicating a good safety profile for the valves implanted in this series. CONCLUSION: The general distribution of implant sizes in the US indicates that cardiac surgeons may be under-sizing the Top Hat supra-annular aortic valve...

  11. The analysis of the annular fuel performance in steady state condition by using AFPAC code

    International Nuclear Information System (INIS)

    He Xiaojun; Ji Songtao; Zhang Yingchao

    2012-01-01

    The fuel performance code AFPAC v1.0 is used to analyze annular fuel's behavior under steady state conditions, including neutronics, thermal hydraulic, rod deformation, fission gas release and rod internal pressure. The calculation results show that: 1) Annular fuel has a good steady irradiation performance at 150% power level as current LWRs' with burnup up to 50 GWd/t, and all parameters, such as temperature, rod internal pressure and rod deformation, are meet the rod design criteria for current fuel of PWRs: 2) Compared to the solid fuel under the same irradiation condition. annular fuel has lower temperature, smaller deformation, lower fission gas release and lower pressure at EOL. From the point of view of steady irradiation performance, the safety of reactors can significantly improved by u sing the annular fuel. (authors)

  12. An iterative method for the solution of nonlinear systems using the Faber polynomials for annular sectors

    Energy Technology Data Exchange (ETDEWEB)

    Myers, N.J. [Univ. of Durham (United Kingdom)

    1994-12-31

    The author gives a hybrid method for the iterative solution of linear systems of equations Ax = b, where the matrix (A) is nonsingular, sparse and nonsymmetric. As in a method developed by Starke and Varga the method begins with a number of steps of the Arnoldi method to produce some information on the location of the spectrum of A. This method then switches to an iterative method based on the Faber polynomials for an annular sector placed around these eigenvalue estimates. The Faber polynomials for an annular sector are used because, firstly an annular sector can easily be placed around any eigenvalue estimates bounded away from zero, and secondly the Faber polynomials are known analytically for an annular sector. Finally the author gives three numerical examples, two of which allow comparison with Starke and Varga`s results. The third is an example of a matrix for which many iterative methods would fall, but this method converges.

  13. Changes in Tricuspid Annular Geometry in Patients with Functional Tricuspid Regurgitation

    NARCIS (Netherlands)

    Hai, Ting; Amador, Yannis; Mahmood, Feroze; Jeganathan, Jelliffe; Khamooshian, Arash; Knio, Ziyad O.; Matyal, Robina; Nicoara, Alina; Liu, David C.; Senthilnathan, Venkatachalam; Khabbaz, Kamal R.

    2017-01-01

    Objective: To determine whether the indices of tricuspid annular dynamics that signify irreversible tricuspid valvular remodeling can improve surgical decision making by helping to better identify patients with functional tricuspid regurgitation who could benefit from annuloplasty. Design:

  14. TORCs: transducers of regulated CREB activity.

    Science.gov (United States)

    Conkright, Michael D; Canettieri, Gianluca; Screaton, Robert; Guzman, Ernesto; Miraglia, Loren; Hogenesch, John B; Montminy, Marc

    2003-08-01

    The cAMP responsive factor CREB stimulates gene expression, following its phosphorylation at Ser133, via recruitment of the coactivator CBP. In certain cell types, CREB also functions as a constitutive activator, although the underlying mechanisms are not understood. Here, we characterize a conserved family of coactivators, designated TORCs, for Transducers of Regulated CREB activity, that enhances CRE-dependent transcription via a phosphorylation-independent interaction with the bZIP DNA binding/dimerization domain of CREB. TORC recruitment does not appear to modulate CREB DNA binding activity, but rather enhances the interaction of CREB with the TAF(II)130 component of TFIID following its recruitment to the promoter. Remarkably, in certain mucoepidermoid carcinomas, a chromosomal translocation fuses the CREB binding domain of TORC1 to the Notch coactivator Mastermind (MAML2). As expression of the TORC1-MAML2 chimera strongly induced target gene expression via CREB, our results reveal a mechanism by which CREB stimulates transcription in normal and transformed cells.

  15. Supra-annular valve strategy for an early degenerated transcatheter balloon-expandable heart valve.

    Science.gov (United States)

    Kamioka, Norihiko; Caughron, Hope; Corrigan, Frank; Block, Peter; Babaliaros, Vasilis

    2018-01-23

    Currently, there are no recommendations regarding the selection of valve type for a transcatheter heart valve (THV)-in-THV procedure. A supra-annular valve design may be superior in that it results in a larger effective orifice area and may have a lower chance of valve thrombosis after THV-in-THV. In this report, we describe the use of a supra-annular valve strategy for an early degenerated THV. © 2018 Wiley Periodicals, Inc.

  16. A bi-annular-gap magnetorheological energy absorber for shock and vibration mitigation

    Science.gov (United States)

    Bai, Xian-Xu; Wereley, Norman M.; Choi, Young-Tai; Wang, Dai-Hua

    2012-04-01

    For semi-active shock and vibration mitigation systems using magnetorheological energy absorbers (MREAs), the minimization of the field-off damper force of the MREA at high speed is of particular significance because the damper force due to the viscous damping at high speed becomes too excessive and thus the controllable dynamic force range that is defined by the ratio of the field-on damper force to the field-off damper force is significantly reduced. In this paper, a bi-annular-gap MREA with an inner-set permanent magnet is proposed to decrease the field-off damper force at high speed while keeping appropriate dynamic force range for improving shock and vibration mitigation performance. In the bi-annular-gap MREA, two concentric annular gaps are configured in parallel so as to decrease the baseline damper force and both magnetic activation methods using the electromagnetic coil winding and the permanent magnet are used to keep holding appropriate magnetic intensity in these two concentric annular gaps in the consideration of failure of the electric power supply. An initial field-on damper force is produced by the magnetic field bias generated from the inner-set permanent magnet. The initial damper force of the MREA can be increased (or decreased) through applying positive (or negative) current to the electromagnetic coil winding inside the bi-annular-gap MREA. After establishing the analytical damper force model of the bi-annular-gap MREA using a Bingham-plastic nonlinear fluid model, the principle and magnetic properties of the MREA are analytically validated and analyzed via electromagnetic finite element analysis (FEA). The performance of the bi-annular-gap MREA is also theoretically compared with that of a traditional single-annular- gap MREA with the constraints of an identical volume by the performance matrix, such as the damper force, dynamic force range, and Bingham number with respect to different excitation velocities.

  17. Performance Improvement of High Frequency Aluminum Nitride Ultrasonic Transducers

    Directory of Open Access Journals (Sweden)

    Yangjie Wei

    2013-01-01

    Full Text Available This paper presents three methods to improve the performance of a high frequency aluminum nitride (AlN ultrasonic transducer. For a high frequency AlN ultrasonic transducer, its properties are related with its top electrode size, electrical impedance matching and layers of the piezoelectric plate. However, until now, no research has been published to analyze their influence on the performance of AlN ultrasonic transducers, especially in the frequency range above 200 MHz. First, two factors related with the top electrode size are proposed based on transmission coefficient and stored energy, and analysis is performed on an Al-AlN-Al on silicon wafers with different electrode sizes. The result proves when the electrode size is 1mm2, the transducer can provide the maximum output voltage and the maximal signal- to-noise ratio (SNR. Then, electrical impedance matching is conducted to improve the performance of transducers, and the experiment result shows that after matching, the resolution and sensitivity have been improved. Finally, a stacked AlN transducer is developed and its model is constructed to analyze its properties in time domain and frequency domain. The comparison between the simulation and the experiment shows the effectiveness of the proposed model, and a stacked structure can be used to improve the sensitivity of a high frequency AlN ultrasonic transducer.

  18. Bonding and impedance matching of acoustic transducers using silver epoxy.

    Science.gov (United States)

    Son, Kyu Tak; Lee, Chin C

    2012-04-01

    Silver epoxy was selected to bond transducer plates on glass substrates. The properties and thickness of the bonding medium affect the electrical input impedance of the transducer. Thus, the thickness of the silver epoxy bonding layer was used as a design parameter to optimize the structure for the transducer input impedance to match the 50 Ω output impedance of most radio frequency (RF) generators. Simulation and experimental results show that nearly perfect matching is achieved without using any matching circuit. At the matching condition, the transducer operates at a frequency band a little bit below the half-wavelength resonant frequency of the piezoelectric plate. In experiments, lead titanate (PT) piezoelectric plates were employed. Both full-size, 11.5 mm × 2 mm × 0.4 mm, and half-size, 5.75 mm × 2 mm × 0.4 mm, can be well matched using optimal silver epoxy thickness. The transducer assemblies demonstrate high efficiency. The conversion loss from electrical power to acoustic power in soda-lime glass is 4.3 dB. This loss is low considering the fact that the transducers operate at off-resonance by 12%. With proper choice of silver epoxy thickness, the transducer can be matched at the fundamental, the 3rd and 5th harmonic frequencies. This leads to the possible realization of triple-band transducers. Reliability was assessed with thermal cycling test according to Telcordia GR-468-Core recommendation. Of the 30 transducer assemblies tested, none broke until 2900 cycles and 27 have sustained beyond 4050 cycles. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Numerical Study of Transition of an Annular Lift Fan Aircraft

    Directory of Open Access Journals (Sweden)

    Yun Jiang

    2016-09-01

    Full Text Available The present study aimed at studying the transition of annular lift fan aircraft through computational fluid dynamics (CFD simulations. The oscillations of lift and drag, the optimization for the figure of merit, and the characteristics of drag, yawing, rolling and pitching moments in transition are studied. The results show that a two-stage upper and lower fan lift system can generate oscillations of lift and drag in transition, while a single-stage inner and outer fan lift system can eliminate the oscillations. The characteristics of momentum drag of the single-stage fans in transition are similar to that of the two-stage fans, but with the peak of drag lowered from 0.63 to 0.4 of the aircraft weight. The strategy to start transition from a negative angle of attack −21° further reduces the peak of drag to 0.29 of the weight. The strategy also reduces the peak of pitching torque, which needs upward extra thrusts of 0.39 of the weight to eliminate. The peak of rolling moment in transition needs differential upward thrusts of 0.04 of the weight to eliminate. The requirements for extra thrusts in transition lead to a total thrust–weight ratio of 0.7, which makes the aircraft more efficient for high speed cruise flight (higher than 0.7 Ma.

  20. Annular Air Leaks in a liquid hydrogen storage tank

    Science.gov (United States)

    Krenn, AG; Youngquist, RC; Starr, SO

    2017-12-01

    Large liquid hydrogen (LH2) storage tanks are vital infrastructure for NASA, the DOD, and industrial users. Over time, air may leak into the evacuated, perlite filled annular region of these tanks. Once inside, the extremely low temperatures will cause most of the air to freeze. If a significant mass of air is allowed to accumulate, severe damage can result from nominal draining operations. Collection of liquid air on the outer shell may chill it below its ductility range, resulting in fracture. Testing and analysis to quantify the thermal conductivity of perlite that has nitrogen frozen into its interstitial spaces and to determine the void fraction of frozen nitrogen within a perlite/frozen nitrogen mixture is presented. General equations to evaluate methods for removing frozen air, while avoiding fracture, are developed. A hypothetical leak is imposed on an existing tank geometry and a full analysis of that leak is detailed. This analysis includes a thermal model of the tank and a time-to-failure calculation. Approaches to safely remove the frozen air are analyzed, leading to the conclusion that the most feasible approach is to allow the frozen air to melt and to use a water stream to prevent the outer shell from chilling.

  1. Current Density Measurements of an Annular-Geometry Ion Engine

    Science.gov (United States)

    Shastry, Rohit; Patterson, Michael J.; Herman, Daniel A.; Foster, John E.

    2012-01-01

    The concept of the annular-geometry ion engine, or AGI-Engine, has been shown to have many potential benefits when scaling electric propulsion technologies to higher power. However, the necessary asymmetric location of the discharge cathode away from thruster centerline could potentially lead to non-uniformities in the discharge not present in conventional geometry ion thrusters. In an effort to characterize the degree of this potential non-uniformity, a number of current density measurements were taken on a breadboard AGI-Engine. Fourteen button probes were used to measure the ion current density of the discharge along a perforated electrode that replaced the ion optics during conditions of simulated beam extraction. Three Faraday probes spaced apart in the vertical direction were also used in a separate test to interrogate the plume of the AGI-Engine during true beam extraction. It was determined that both the discharge and the plume of the AGI-Engine are highly uniform, with variations under most conditions limited to +/-10% of the average current density in the discharge and +/-5% of the average current density in the plume. Beam flatness parameter measured 30 mm from the ion optics ranged from 0.85 - 0.95, and overall uniformity was shown to generally increase with increasing discharge and beam currents. These measurements indicate that the plasma is highly uniform despite the asymmetric location of the discharge cathode.

  2. Critical heat flux experimentation in an annular test section

    International Nuclear Information System (INIS)

    White, J.D.; Levin, A.E.

    1978-01-01

    Steady-state critical heat flux experiments have been performed in the Forced Convection Test Facility (FCTF), an annular test section containing a single electrically heated rod, for the purpose of testing the applicability of existing critical heat flux correlations. Good accuracy has been obtained using the MacBeth-Barnett critical heat flux correlation for annuli, corrected for the ''stepped cosine'' power profile of the heater. The equivalent diameter of the test section, based on the wetted perimeter, is 2.1 cm (0.83 in.); the heated-to-wetted-perimeter ratio is 0.252. The heated length of the heater rod is 366 cm (144 in.). Nominal pressures for the tests have ranged from 7.2 to 15.5 MN/m 2 (1044 to 2250 psia); coolant flow rates have been 0.32 dm 3 /sec (5 gpm), 0.63 dm 3 /sec (10 gpm), and 1.26 dm 3 /sec (20 gpm); and heater powers of 72 kW, 122 kW, and 144 kW have been used. Maximum error in prediction of first observed critical heat flux is 21 percent; rms error is 11.7 percent. Attempts have also been made to predict the occurrence of critical heat flux during blowdowns (depressurization transients) of the FCTF. The results of these predictions are inconclusive at this time

  3. Annular tidal regenerator engine for nuclear circulatory support systems

    International Nuclear Information System (INIS)

    Hagen, K.G.; Ruggles, A.E.; Fam, S.S.; Torti, V.A.

    1975-01-01

    In order to simplify the configuration of the tidal regenerator engine nuclear-powered circulatory support system, thereby drastically reducing its size and improving the intrinsic reliability, the engine has been redesigned. This redesign focuses on allowing power to be extracted at the low temperature end of the engine utilizing a piston-cylinder arrangement wherein all of the necessary heat transfer processes occur in the annular gap between the piston and cylinder. In all other respects the engine retains its basic characteristics as a hybrid between a Stirling engine and a Rankine engine. A significant advantage of the new arrangement is the ability to raise the superheat temperature limit from 650 0 F to over 900 0 F. This has yielded an increase in engine efficiency from 10 percent to 14 percent, and further increases are anticipated by utilizing an expansion and/or a binary version of the engine. The implantable system volume has been reduced by a factor of three and orientation insensitivity with respect to gravity has been demonstrated. Many system components have already demonstrated endurances of several thousand hours

  4. An Unusual Presentation of Annular Pancreas: A Case Report

    Directory of Open Access Journals (Sweden)

    Saleheh Ala

    2015-01-01

    Full Text Available Abstract Annular pancreas (AP is a rare congenital malformation resulting from failure of pancreas ventral anlage rotation with the duodenum. This leads to a ring of pancreatic tissue that envelops the duodenum. Clinical manifestations of AP most commonly develop in infancy or early childhood but can present at any age. The diagnosis of AP, usually suggested by an upper GI series or abdominal CT scan, but surgery is considered the gold standard diagnostic method. Surgical bypass of the annulus in all patients with symptomatic AP is recommended. We report a one year old girl who presented with intermittent, non projectile, non bilious vomiting that occurred 1h to 2h after feeding since neonatal period. Upper GI contrast study demonstrates, a dilated duodenal bulb associated with narrowing of post bulbar area. The patient underwent surgical correction of the obstruction. A bypass of the ectopic pancreas tissue was performed by duodenoduodenostomy. Considering the rarity of this congenital abnormality, presenting with chronic partial duodenal obstruction, and its successful correction by surgical means have prompted us to report the case.

  5. Pollution technology program, can-annular combustor engines

    Science.gov (United States)

    Roberts, R.; Fiorentino, A. J.; Greene, W.

    1976-01-01

    A Pollution Reduction Technology Program to develop and demonstrate the combustor technology necessary to reduce exhaust emissions for aircraft engines using can-annular combustors is described. The program consisted of design, fabrication, experimental rig testing and assessment of results and was conducted in three program elements. The combustor configurations of each program element represented increasing potential for meeting the 1979 Environmental Protection Agency (EPA) emission standards, while also representing increasing complexity and difficulty of development and adaptation to an operational engine. Experimental test rig results indicate that significant reductions were made to the emission levels of the baseline JT8D-17 combustor by concepts in all three program elements. One of the Element I single-stage combustors reduced carbon monoxide to a level near, and total unburned hydrocarbons (THC) and smoke to levels below the 1979 EPA standards with little or no improvement in oxides of nitrogen. The Element II two-stage advanced Vorbix (vortex burning and mixing) concept met the standard for THC and achieved significant reductions in CO and NOx relative to the baseline. Although the Element III prevaporized-premixed concept reduced high power NOx below the Element II results, there was no improvement to the integrated EPA parameter relative to the Vorbix combustor.

  6. Monthly rifampicin, ofloxacin, and minocycline therapy for generalized and localized granuloma annulare

    Directory of Open Access Journals (Sweden)

    Shilpa Garg

    2015-01-01

    Full Text Available Background: The localized form of granuloma annulare is usually self-limiting, resolving within 2 years. Generalized granuloma annulare, on the other hand, runs a protracted course, with spontaneous resolution being rare. It is also characterized by a later age of onset, an increased incidence of diabetes mellitus, poor response to therapy, and an increased prevalence of HLA Bw35. Objective: To assess the efficacy of monthly pulsed rifampicin, ofloxacin, and minocycline (ROM therapy in the management of granuloma annulare. Methods : Six biopsy proven patients of granuloma annulare were included in the study, five of the generalized variety, and one localized. Three of these patients were resistant to standard modalities of treatment. All six patients were treated with pulses of once monthly ROM till complete resolution of all lesions. Results were analyzed in terms of complete resolution of lesions and side effects. Presence of comorbid conditions was noted. Result: All six patients were successfully treated with 4-8 pulses of monthly ROM. None of the patients reported any adverse effects. Limitations: Small sample size and the lack of a control group are limitations. Conclusion: Treatment with pulses of once monthly ROM caused complete resolution of lesions in both localized and generalized granuloma annulare, even in cases recalcitrant to conventional therapy. There were no side effects in any of the patients. Larger trials are needed to substantiate the efficacy of monthly ROM in granuloma annulare.

  7. An optical system design that converts a Gaussian to a flattop annular beam

    Science.gov (United States)

    Li, Chaochen; Wu, Tengfei; Wang, Yu

    2015-10-01

    Flattop annular beam has been predicted with good character over an increasing application, but the generating of flattop annular beam is rarely mentioned by academic article. In our paper, an optical refractive system, which is designed to achieve flattop annular beam, are proposed. The cone prism is commonly used to get an annular beam, however, the beam intensity distribution is non-uniform. In our design, an additional aspheric lens is placed in front of the cone prism along the optical axis. The lens parameters are theoretically analyzed and well optimized to homogenize the optical field. Furthermore, to lower the requirement of machining accuracy, a pair of aspheric lenses is also designed, which can be used independently to generate flattop annular beam. It combines the function of cone prism and aspheric lens, so as to replace them both. The performance of the implementations has been demonstrated in detail. Simulation result shows that the proposed design is effective and feasible. It is hope that our work would be helpful in related fields. Flattop annular beam, Aspheric lens, Cone prism

  8. Dismantling the activated annular water tank of the Rheinsberg nuclear power plant

    International Nuclear Information System (INIS)

    Klietz, Maik; Konitzer, Arnold; Luedeke, Michael

    2010-01-01

    Acting on behalf of Energiewerke Nord GmbH Lubmin, Anlagen- und Kraftwerksrohrleitungsbau Greifswald GmbH (AKB) planned and built a station for disassembly of the activated annular water tank (RWB) of the decommissioned Rheinsberg nuclear power plant. As part of this demolition step, the annular water tank must be conditioned and disposed of as a component of the reactor facility. This required planning, manufacturing, testing and construction on site of suitable disassembly and handling techniques and the necessary plant and equipment. The client opted for disassembly by means of a diamond cable saw for conditioning the annular water tank into segments fit for shipping, and defined the basic components for the disassembly station in a specification of deliveries and services. The disassembly station serves to divide the annular water tank by means of diamond cable saws into 2 sections in such a way that segment pieces for transport are produced. The existing activation of the annular water tank also entailed the need to plan for the shortest possible time to be spent on handling near the annular water tank, providing radiological protection to the personnel, and performing the sawing steps from a separate operating console assisted by camera surveillance. After works acceptance tests at the manufacturer's, AKB, in October 2009 and February 2010, the disassembly station was delivered to the customer at Rheinsberg KKR free from defects in June 2010. (orig.)

  9. Fluid-Structure Interaction Analysis on Turbulent Annular Seals of Centrifugal Pumps during Transient Process

    Directory of Open Access Journals (Sweden)

    Qinglei Jiang

    2011-01-01

    Full Text Available The current paper studies the influence of annular seal flow on the transient response of centrifugal pump rotors during the start-up period. A single rotor system and three states of annular seal flow were modeled. These models were solved using numerical integration and finite difference methods. A fluid-structure interaction method was developed. In each time step one of the three annular seal models was chosen to simulate the annular seal flow according to the state of rotor systems. The objective was to obtain a transient response of rotor systems under the influence of fluid-induced forces generated by annular seal flow. This method overcomes some shortcomings of the traditional FSI method by improving the data transfer process between two domains. Calculated results were in good agreement with the experimental results. The annular seal was shown to have a supportive effect on rotor systems. Furthermore, decreasing the seal clearance would enhance this supportive effect. In the transient process, vibration amplitude and critical speed largely changed when the acceleration of the rotor system increased.

  10. Burnable Absorber-Filled Annular UO{sub 2} Fuels for PWR

    Energy Technology Data Exchange (ETDEWEB)

    Yahya, Mohd-Syukri; Kim, Yonghee [KAIST, Daejeon (Korea, Republic of); Chung, ChangKyu [KEPCO EnC, Daejeon (Korea, Republic of)

    2015-10-15

    Its central annulus hole also provides an additional plenum for the fission gas release. In fact, annular UO{sub 2} fuels have successfully been used in commercial Russian's nuclear reactors for decades. It was upon this notion that a study was recently performed to re-investigate neutronic characteristics of the annular fuel in a rod-cell lattice. The said study also proposed an innovative integral burnable absorber (BA) concept by loading of a porous BA rod inside central hole of the annular fuel. This current work aims to extend the said investigation by characterizing neutronic performances of the BA-filled annular fuels in standard PWR 17x17 and 16x16 fuel assembly lattices. Preliminary results suggested promising potentials of the novel BA concept in managing the assembly lattice reactivity and power peaking. All calculations were performed using the Monte Carlo Serpent code with ENDF/B7.0 library. This paper demonstrates neutronic feasibilities of the BA-filled annular fuels in standard PWR 17x17 and 16x16 fuel assembly lattices. One notes that the BA-filled annular fuel-loaded lattice display comparable neutronic characteristics to the benchmarked commercial BA designs, especially in terms of reactivity and peaking factor management.

  11. Imaging for Borehole Wall by a Cylindrical Linear Phased Array

    International Nuclear Information System (INIS)

    Bi-Xing, Zhang; Fang-Fang, Shi; Xian-Mei, Wu; Jun-Jie, Gong; Cheng-Guang, Zhang

    2010-01-01

    A new ultrasonic cylindrical linear phased array (CLPA) transducer is designed and fabricated for the borehole wall imaging in petroleum logging based on the previous theoretical researches. First, the CLPA transducer, which is made up of numbers of the piezoelectric elements distributed on the surface of a cylinder uniformly, is designed and fabricated. By transmitting and receiving acoustic waves with 16 active elements and using different groups of the elements under the control of the electric system, the CLPA can scan all areas of the borehole wall dynamically and rapidly without a traditional mechanism around the borehole axis. Then, the theoretical and experimental investigations are conducted in detail for the borehole wall scanning and imaging by the steel pipe and casing borehole with defects distributed in different shapes and directions. It is shown by experiments that the CLPA transducer has good focusing characteristic and good resolution for the borehole wall imaging in acoustic logging

  12. Underwater Imaging Using a 1 × 16 CMUT Linear Array.

    Science.gov (United States)

    Zhang, Rui; Zhang, Wendong; He, Changde; Zhang, Yongmei; Song, Jinlong; Xue, Chenyang

    2016-03-01

    A 1 × 16 capacitive micro-machined ultrasonic transducer linear array was designed, fabricated, and tested for underwater imaging in the low frequency range. The linear array was fabricated using Si-SOI bonding techniques. Underwater transmission performance was tested in a water tank, and the array has a resonant frequency of 700 kHz, with pressure amplitude 182 dB (μPa·m/V) at 1 m. The -3 dB main beam width of the designed dense linear array is approximately 5 degrees. Synthetic aperture focusing technique was applied to improve the resolution of reconstructed images, with promising results. Thus, the proposed array was shown to be suitable for underwater imaging applications.

  13. Underwater Imaging Using a 1 × 16 CMUT Linear Array

    Directory of Open Access Journals (Sweden)

    Rui Zhang

    2016-03-01

    Full Text Available A 1 × 16 capacitive micro-machined ultrasonic transducer linear array was designed, fabricated, and tested for underwater imaging in the low frequency range. The linear array was fabricated using Si-SOI bonding techniques. Underwater transmission performance was tested in a water tank, and the array has a resonant frequency of 700 kHz, with pressure amplitude 182 dB (μPa·m/V at 1 m. The −3 dB main beam width of the designed dense linear array is approximately 5 degrees. Synthetic aperture focusing technique was applied to improve the resolution of reconstructed images, with promising results. Thus, the proposed array was shown to be suitable for underwater imaging applications.

  14. Evaluation of tricuspid annular plane systolic excursion measured with cardiac MRI in children with tetralogy of Fallot.

    Science.gov (United States)

    Soslow, Jonathan H; Usoro, Emem; Wang, Li; Parra, David A

    2016-04-01

    Aneurysmal dilation of the right ventricular outflow tract complicates assessment of right ventricular function in patients with repaired tetralogy of Fallot. Tricuspid annular plane systolic excursion is commonly used to estimate ejection fraction. We hypothesised that tricuspid annular plane systolic excursion measured by cardiac MRI approximates global and segmental right ventricular function, specifically right ventricular sinus ejection fraction, in children with repaired tetralogy of Fallot. Tricuspid annular plane systolic excursion was measured retrospectively on cardiac MRIs in 54 patients with repaired tetralogy of Fallot. Values were compared with right ventricular global, sinus, and infundibular ejection fractions. Tricuspid annular plane systolic excursion was indexed to body surface area, converted into a fractional value, and converted into published paediatric Z-scores. Tricuspid annular plane systolic excursion measurements had good agreement between observers. Right ventricular ejection fraction did not correlate with the absolute or indexed tricuspid annular plane systolic excursion and correlated weakly with fractional tricuspid annular plane systolic excursion (r=0.41 and p=0.002). Segmental right ventricular function did not appreciably improve correlation with any of the tricuspid annular plane systolic excursion measures. Paediatric Z-scores were unable to differentiate patients with normal and abnormal right ventricular function. Tricuspid annular plane systolic excursion measured by cardiac MRI correlates poorly with global and segmental right ventricular ejection fraction in children with repaired tetralogy of Fallot. Tricuspid annular plane systolic excursion is an unreliable approximation of right ventricular function in this patient population.

  15. USE OF PELTIER COOLERS AS SOIL HEAT FLUX TRANSDUCERS.

    Science.gov (United States)

    Weaver, H.L.; Campbell, G.S.

    1985-01-01

    Peltier coolers were modified and calibrated to serve as soil heat flux transducers. The modification was to fill their interiors with epoxy. The average calibration constant on 21 units was 13. 6 plus or minus 0. 8 kW m** minus **2 V** minus **1 at 20 degree C. This sensitivity is about eight times that of the two thermopile transducers with which comparisons were made. The thermal conductivity of the Peltier cooler transducers was 0. 4 W m** minus **1 degree C** minus **1, which is comparable to that of dry soil.

  16. Ultrasonic Transducer Peak-to-Peak Optical Measurement

    Directory of Open Access Journals (Sweden)

    Pavel Skarvada

    2012-01-01

    Full Text Available Possible optical setups for measurement of the peak-to-peak value of an ultrasonic transducer are described in this work. The Michelson interferometer with the calibrated nanopositioner in reference path and laser Doppler vibrometer were used for the basic measurement of vibration displacement. Langevin type of ultrasonic transducer is used for the purposes of Electro-Ultrasonic Nonlinear Spectroscopy (EUNS. Parameters of produced mechanical vibration have to been well known for EUNS. Moreover, a monitoring of mechanical vibration frequency shift with a mass load and sample-transducer coupling is important for EUNS measurement.

  17. Electromechanically active polymer transducers: research in Europe

    Science.gov (United States)

    Carpi, Federico; Graz, Ingrid; Jager, Edwin; Ladegaard Skov, Anne; Vidal, Frédéric

    2013-10-01

    Smart materials and structures based on electromechanically active polymers (EAPs) represent a fast growing and stimulating field of research and development. EAPs are materials capable of changing dimensions and/or shape in response to suitable electrical stimuli. They are commonly classified in two major families: ionic EAPs (activated by an electrically induced transport of ions and/or solvent) and electronic EAPs (activated by electrostatic forces). These polymers show interesting properties, such as sizable active strains and/or stresses in response to electrical driving, high mechanical flexibility, low density, structural simplicity, ease of processing and scalability, no acoustic noise and, in most cases, low costs. Since many of these characteristics can also describe natural muscle tissues from an engineering standpoint, it is not surprising that EAP transducers are sometimes also referred to as 'muscle-like smart materials' or 'artificial muscles'. They are used not only to generate motion, but also to sense or harvest energy from it. In particular, EAP electromechanical transducers are studied for applications that can benefit from their 'biomimetic' characteristics, with possible usages from the micro- to the macro-scale, spanning several disciplines, such as mechatronics, robotics, automation, biotechnology and biomedical engineering, haptics, fluidics, optics and acoustics. Currently, the EAP field is just undergoing its initial transition from academic research into commercialization, with companies starting to invest in this technology and the first products appearing on the market. This focus issue is intentionally aimed at gathering contributions from the most influential European groups working in the EAP field. In fact, today Europe hosts the broadest EAP community worldwide. The rapid expansion of the EAP field in Europe, where it historically has strong roots, has stimulated the creation of the 'European Scientific Network for Artificial

  18. 3D-printed adaptive acoustic lens as a disruptive technology for transcranial ultrasound therapy using single-element transducers

    Science.gov (United States)

    Maimbourg, Guillaume; Houdouin, Alexandre; Deffieux, Thomas; Tanter, Mickael; Aubry, Jean-François

    2018-01-01

    The development of multi-element arrays for better control of the shape of ultrasonic beams has opened the way for focusing through highly aberrating media, such as the human skull. As a result, the use of brain therapy with transcranial-focused ultrasound has rapidly grown. Although effective, such technology is expensive. We propose a disruptive, low-cost approach that consists of focusing a 1 MHz ultrasound beam through a human skull with a single-element transducer coupled with a tailored silicone acoustic lens cast in a 3D-printed mold and designed using computed tomography-based numerical acoustic simulation. We demonstrate on N  =  3 human skulls that adding lens-based aberration correction to a single-element transducer increases the deposited energy on the target 10 fold.

  19. Performance Evaluation of Pressure Transducers for Water Impacts

    Science.gov (United States)

    Vassilakos, Gregory J.; Stegall, David E.; Treadway, Sean

    2012-01-01

    The Orion Multi-Purpose Crew Vehicle is being designed for water landings. In order to benchmark the ability of engineering tools to predict water landing loads, test programs are underway for scale model and full-scale water impacts. These test programs are predicated on the reliable measurement of impact pressure histories. Tests have been performed with a variety of pressure transducers from various manufacturers. Both piezoelectric and piezoresistive devices have been tested. Effects such as thermal shock, pinching of the transducer head, and flushness of the transducer mounting have been studied. Data acquisition issues such as sampling rate and anti-aliasing filtering also have been studied. The response of pressure transducers have been compared side-by-side on an impulse test rig and on a 20-inch diameter hemisphere dropped into a pool of water. The results have identified a range of viable configurations for pressure measurement dependent on the objectives of the test program.

  20. Failure Analysis of High-Power Piezoelectric Transducers

    National Research Council Canada - National Science Library

    Gabrielson, T. B

    2005-01-01

    ... and stress in a piezoelectric material. For a transducer operated near resonance, there will be "hot spots" or regions of locally intense stress and electric field that precipitate premature failure...

  1. Capacitive Micromachined Ultrasonic Transducers (CMUTs for Underwater Imaging Applications

    Directory of Open Access Journals (Sweden)

    Jinlong Song

    2015-09-01

    Full Text Available A capacitive micromachined ultrasonic transducer structure for use in underwater imaging is designed, fabricated and tested in this paper. In this structure, a silicon dioxide insulation layer is inserted between the top electrodes and the vibration membrane to prevent ohmic contact. The capacitance-voltage (C-V characteristic curve shows that the transducer offers suitable levels of hysteresis and repeatability performance. The −6 dB center frequency is 540 kHz and the transducer has a bandwidth of 840 kHz for a relative bandwidth of 155%. Underwater pressure of 143.43 Pa is achieved 1 m away from the capacitive micromachined ultrasonic transducer under 20  excitation. Two-dimensional underwater ultrasonic imaging, which is able to prove that a rectangular object is present underwater, is achieved. The results presented here indicate that our work will be highly beneficial for the establishment of an underwater ultrasonic imaging system.

  2. Tunable interdigital transducers made of piezoelectric macro-fiber composite

    Science.gov (United States)

    Mańka, Michał; Martowicz, Adam; Rosiek, Mateusz; Stepinski, Tadeusz; Uhl, Tadeusz

    2016-11-01

    The number of applications of Lamb waves (LWs) based structural health monitoring (SHM) has significantly increased in recent decades. The growth of interest results from several advantages of this diagnostic technique, that is, considerable mode selectivity and directivity that allow for the assessment of the technical condition of a monitored structure. Successful applications of LWs in the field of SHM stimulate continuous improvement of the transducers’ design to enable capturing more reliable diagnostic data. The paper introduces a new type of transducer that may be used in the LWs based SHM systems, namely tunable-interdigital transducer (T-IDT) based on macro-fiber composites (MFC). The authors provide a short overview on different types of transducers that may be used in SHM applications, followed by a detailed description of the structure of proposed T-IDT. Finally, the results of numerical and experimental tests carried out employing the proposed transducer are discussed and compared to those obtained with a traditional IDT.

  3. Spatial impulse response of a rectangular double curved transducer

    DEFF Research Database (Denmark)

    Bæk, David; Jensen, Jørgen Arendt; Willatzen, Morten

    2012-01-01

    Calculation of the pressure field from transducers having both a convex and a concave surface geometry is a complicated assignment that often is accomplished by subdividing the transducer surface into smaller flat elements of which the spatial impulse response is known. This method is often seen...... applied to curved transducers because an analytical solution is un-known. In this work a semi-analytical algorithm for the exact solution to a first order in diffraction effect of the spatial impulse response of rectangular shaped double curved transducers is presented. The algorithm and an approximation...... approximations ranging from 0.03 % to 0.8 % relative to a numerical solution for the spatial impulse response. It is shown that the presented algorithm gives consistent results with Field II for a linear flat, a linear focused, and a convex non-focused element. Best solution was found to be 0.01 % with a three...

  4. Wideband Single Crystal Transducer for Bone Characterization, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — TRS proposes to develop a simple-to-use, launch capable, ultrasound transducer that is capable of producing the necessary bandwidth to accurately determine in vivo...

  5. Integration of Capacitive Micromachined Ultrasound Transducers to Microfluidic Devices

    KAUST Repository

    Viržonis, Darius

    2013-10-22

    The design and manufacturing flexibility of capacitive micromachined ultrasound transducers (CMUT) makes them attractive option for integration with microfluidic devices both for sensing and fluid manipulation. CMUT concept is introduced here by presentin

  6. Thermal properties photonic crystal fiber transducers with ferromagnetic nanoparticles

    Science.gov (United States)

    Przybysz, N.; Marć, P.; Kisielewska, A.; Jaroszewicz, L. R.

    2015-12-01

    The main aim of the research is to design new types of fiber optic transducers based on filled photonic crystal fibers for sensor applications. In our research we propose to use as a filling material nanoparticles' ferrofluids (Fe3O4 NPs). Optical properties of such transducers are studied by measurements of spectral characteristics' changes when transducers are exposed to temperature and magnetic field changes. From synthesized ferrofluid several mixtures with different NPs' concentrations were prepared. Partially filled commercially available photonic crystal fiber LMA 10 (NKT Photonics) was used to design PCF transducers. Their thermo-optic properties were tested in a temperature chamber. Taking into account magnetic properties of synthetized NPs the patch cords based on a partially filled PM 1550 PCF were measured.

  7. FEM model based optimization of transducer geometry for photoacoustic imaging

    NARCIS (Netherlands)

    Xia, W.; Piras, D.; van Veldhoven, S.; Prins, C; van Leeuwen, Ton; Steenbergen, Wiendelt; Manohar, Srirang

    2012-01-01

    We optimize the design of an ultrasound transducer for photoacoustic breast imaging using FEM analysis. We arrive at a detector design which shows significant improvement in image quality when used in photoacoustic tomographic simulations.

  8. An integrated circuit with transmit beamforming flip-chip bonded to a 2-D CMUT array for 3-D ultrasound imaging.

    Science.gov (United States)

    Wygant, Ira O; Jamal, Nafis S; Lee, Hyunjoo J; Nikoozadeh, Amin; Oralkan, Omer; Karaman, Mustafa; Khuri-Yakub, Butrus T

    2009-10-01

    State-of-the-art 3-D medical ultrasound imaging requires transmitting and receiving ultrasound using a 2-D array of ultrasound transducers with hundreds or thousands of elements. A tight combination of the transducer array with integrated circuitry eliminates bulky cables connecting the elements of the transducer array to a separate system of electronics. Furthermore, preamplifiers located close to the array can lead to improved receive sensitivity. A combined IC and transducer array can lead to a portable, high-performance, and inexpensive 3-D ultrasound imaging system. This paper presents an IC flip-chip bonded to a 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array for 3-D ultrasound imaging. The IC includes a transmit beamformer that generates 25-V unipolar pulses with programmable focusing delays to 224 of the 256 transducer elements. One-shot circuits allow adjustment of the pulse widths for different ultrasound transducer center frequencies. For receiving reflected ultrasound signals, the IC uses the 32-elements along the array diagonals. The IC provides each receiving element with a low-noise 25-MHz-bandwidth transimpedance amplifier. Using a field-programmable gate array (FPGA) clocked at 100 MHz to operate the IC, the IC generated properly timed transmit pulses with 5-ns accuracy. With the IC flip-chip bonded to a CMUT array, we show that the IC can produce steered and focused ultrasound beams. We present 2-D and 3-D images of a wire phantom and 2-D orthogonal cross-sectional images (Bscans) of a latex heart phantom.

  9. Finite-State Complexity and the Size of Transducers

    Directory of Open Access Journals (Sweden)

    Cristian Calude

    2010-08-01

    Full Text Available Finite-state complexity is a variant of algorithmic information theory obtained by replacing Turing machines with finite transducers. We consider the state-size of transducers needed for minimal descriptions of arbitrary strings and, as our main result, we show that the state-size hierarchy with respect to a standard encoding is infinite. We consider also hierarchies yielded by more general computable encodings.

  10. A novel robotic arm driven by sandwich piezoelectric transducers.

    Science.gov (United States)

    Jiang, Zheng; Wang, Liang; Jin, Jiamei

    2018-03-01

    In this work, a novel robotic arm driven by sandwich piezoelectric transducers is proposed. The proposed robotic arm is composed of three arms and four joints. Each arm consists of a sandwich piezoelectric transducer and an H-shaped hollow frame. The sandwich piezoelectric transducer utilizes frictional force to drive the joints on its both sides to rotate simultaneously. The joint between two arms can be driven to rotate in two perpendicular directions by two sandwich piezoelectric transducers. The rotation of joints results in the arm motion. Utilizing the finite element method, the optimized geometrical parameters of the sandwiched piezoelectric transducer are obtained, and the operating principle is demonstrated. A prototype of the robotic arm is also fabricated and assembled, it is 573 g in weight and 412 mm in length, and the maximum rotation angle of each joint is 160°. The mechanical characteristics of the robotic arm prototype are investigated by experiments. The results indicate that, when the excitation frequency of one sandwich piezoelectric transducer is 37.4 kHz, the arms on its two sides rotate in opposite directions with an average rotational velocity of 320 deg/s at 330 V pp , a resolution of 100 μrad at 230 V pp , and a startup and shutdown response time of 40 ms and 30 ms at 230 V pp , respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. High Frequency Longitudinal Damped Vibrations of a Cylindrical Ultrasonic Transducer

    Directory of Open Access Journals (Sweden)

    Mihai Valentin Predoi

    2014-01-01

    Full Text Available Ultrasonic piezoelectric transducers used in classical nondestructive testing are producing in general longitudinal vibrations in the MHz range. A simple mechanical model of these transducers would be very useful for wave propagation numerical simulations, avoiding the existing complicated models in which the real components of the transducer are modeled by finite elements. The classical model for longitudinal vibrations is not adequate because the generated longitudinal wave is not dispersive, the velocity being the same at any frequency. We have adopted the Rayleigh-Bishop model, which avoids these limitations, even if it is not converging to the first but to the second exact longitudinal mode in an elastic rod, as obtained from the complicated Pochhammer-Chree equations. Since real transducers have significant vibrations damping, we have introduced a damping term in the Rayleigh-Bishop model, increasing the imaginary part and keeping almost identical real part of the wavenumber. Common transducers produce amplitude modulated signals, completely attenuated after several periods. This can be modeled by two close frequencies, producing a “beat” phenomenon, superposed on the high damping. For this reason, we introduce a two-rod Rayleigh-Bishop model with damping. Agreement with measured normal velocity on the transducer free surface is encouraging for continuation of the research.

  12. Experimental Evaluation of Three Designs of Electrodynamic Flexural Transducers.

    Science.gov (United States)

    Eriksson, Tobias J R; Laws, Michael; Kang, Lei; Fan, Yichao; Ramadas, Sivaram N; Dixon, Steve

    2016-08-25

    Three designs for electrodynamic flexural transducers (EDFT) for air-coupled ultrasonics are presented and compared. An all-metal housing was used for robustness, which makes the designs more suitable for industrial applications. The housing is designed such that there is a thin metal plate at the front, with a fundamental flexural vibration mode at ∼50 kHz. By using a flexural resonance mode, good coupling to the load medium was achieved without the use of matching layers. The front radiating plate is actuated electrodynamically by a spiral coil inside the transducer, which produces an induced magnetic field when an AC current is applied to it. The transducers operate without the use of piezoelectric materials, which can simplify manufacturing and prolong the lifetime of the transducers, as well as open up possibilities for high-temperature applications. The results show that different designs perform best for the generation and reception of ultrasound. All three designs produced large acoustic pressure outputs, with a recorded sound pressure level (SPL) above 120 dB at a 40 cm distance from the highest output transducer. The sensitivity of the transducers was low, however, with single shot signal-to-noise ratio ( SNR ) ≃ 15 dB in transmit-receive mode, with transmitter and receiver 40 cm apart.

  13. Home Automation System Based on Intelligent Transducer Enablers

    Science.gov (United States)

    Suárez-Albela, Manuel; Fraga-Lamas, Paula; Fernández-Caramés, Tiago M.; Dapena, Adriana; González-López, Miguel

    2016-01-01

    This paper presents a novel home automation system named HASITE (Home Automation System based on Intelligent Transducer Enablers), which has been specifically designed to identify and configure transducers easily and quickly. These features are especially useful in situations where many transducers are deployed, since their setup becomes a cumbersome task that consumes a significant amount of time and human resources. HASITE simplifies the deployment of a home automation system by using wireless networks and both self-configuration and self-registration protocols. Thanks to the application of these three elements, HASITE is able to add new transducers by just powering them up. According to the tests performed in different realistic scenarios, a transducer is ready to be used in less than 13 s. Moreover, all HASITE functionalities can be accessed through an API, which also allows for the integration of third-party systems. As an example, an Android application based on the API is presented. Remote users can use it to interact with transducers by just using a regular smartphone or a tablet. PMID:27690031

  14. Software for Correcting the Dynamic Error of Force Transducers

    Directory of Open Access Journals (Sweden)

    Naoki Miyashita

    2014-07-01

    Full Text Available Software which corrects the dynamic error of force transducers in impact force measurements using their own output signal has been developed. The software corrects the output waveform of the transducers using the output waveform itself, estimates its uncertainty and displays the results. In the experiment, the dynamic error of three transducers of the same model are evaluated using the Levitation Mass Method (LMM, in which the impact forces applied to the transducers are accurately determined as the inertial force of the moving part of the aerostatic linear bearing. The parameters for correcting the dynamic error are determined from the results of one set of impact measurements of one transducer. Then, the validity of the obtained parameters is evaluated using the results of the other sets of measurements of all the three transducers. The uncertainties in the uncorrected force and those in the corrected force are also estimated. If manufacturers determine the correction parameters for each model using the proposed method, and provide the software with the parameters corresponding to each model, then users can obtain the waveform corrected against dynamic error and its uncertainty. The present status and the future prospects of the developed software are discussed in this paper.

  15. DESIGN AND IMPLEMENTATION OF POTENTIOMETER-BASED NONLINEAR TRANSDUCER EMULATOR

    Directory of Open Access Journals (Sweden)

    Sheroz Khan

    2011-05-01

    Full Text Available This work attempts to design and implement in hardware a transducer with a nonlinear response using potentiometer. Potentiometer is regarded as a linear transducer, while a the response of a nonlinear transducer can be treated as a concatenation of linear segments made out of the response curve of an actual nonlinear transducer at the points of inflections being exhibited by the nonlinear curve. Each straight line segment is characterized by its slope and a constant, called the y-intercept, which is ultimately realized by a corresponding electronic circuit. The complete circuit diagram is made of three stages: (i the input stage for range selection, (ii a digital logic to make appropriate selection, (iii a conditioning circuit for realizing a given straight-line segment identified by its relevant slope and reference voltage. The simulation of the circuit is carried using MULTISIM, and the designed circuit is afterward tested to verify that variations of the input voltage give us an output voltage very close to the response pattern envisaged in the analytical stage of the design. The utility of this work lies in its applications in emulating purpose built transducers that could be used to nicely emulate a transducer in a real world system that is to be controlled by a programmable digital system.

  16. Home Automation System Based on Intelligent Transducer Enablers

    Directory of Open Access Journals (Sweden)

    Manuel Suárez-Albela

    2016-09-01

    Full Text Available This paper presents a novel home automation system named HASITE (Home Automation System based on Intelligent Transducer Enablers, which has been specifically designed to identify and configure transducers easily and quickly. These features are especially useful in situations where many transducers are deployed, since their setup becomes a cumbersome task that consumes a significant amount of time and human resources. HASITE simplifies the deployment of a home automation system by using wireless networks and both self-configuration and self-registration protocols. Thanks to the application of these three elements, HASITE is able to add new transducers by just powering them up. According to the tests performed in different realistic scenarios, a transducer is ready to be used in less than 13 s. Moreover, all HASITE functionalities can be accessed through an API, which also allows for the integration of third-party systems. As an example, an Android application based on the API is presented. Remote users can use it to interact with transducers by just using a regular smartphone or a tablet.

  17. Home Automation System Based on Intelligent Transducer Enablers.

    Science.gov (United States)

    Suárez-Albela, Manuel; Fraga-Lamas, Paula; Fernández-Caramés, Tiago M; Dapena, Adriana; González-López, Miguel

    2016-09-28

    This paper presents a novel home automation system named HASITE (Home Automation System based on Intelligent Transducer Enablers), which has been specifically designed to identify and configure transducers easily and quickly. These features are especially useful in situations where many transducers are deployed, since their setup becomes a cumbersome task that consumes a significant amount of time and human resources. HASITE simplifies the deployment of a home automation system by using wireless networks and both self-configuration and self-registration protocols. Thanks to the application of these three elements, HASITE is able to add new transducers by just powering them up. According to the tests performed in different realistic scenarios, a transducer is ready to be used in less than 13 s. Moreover, all HASITE functionalities can be accessed through an API, which also allows for the integration of third-party systems. As an example, an Android application based on the API is presented. Remote users can use it to interact with transducers by just using a regular smartphone or a tablet.

  18. Effect of Granule Size on Diametric Tolerance of Annular Fuel Pellet

    International Nuclear Information System (INIS)

    Rhee, Young Woo; Kim, Dong Joo; Kim, Jong Hun; Yang, Jae Ho; Kim, Keon Sik; Kang, Ki Won; Song, Kun Woo

    2008-01-01

    A dual cooled annular fuel has been seriously considered as a favorable option for an extended power uprate of a Pressurized Water Reactor fuel assembly. An annular fuel shows a lot of advantages from the point of a fuel safety and its economy due to its unique configurational merit such as an increased heat transfer area and a thin pellet thickness. From the viewpoint of the fuel pellet fabrication, however, the unique shape of annular fuel pellet causes challenging difficulties to satisfy a diametric tolerance. A sintered cylindrical PWR fuel pellet fabricated by a conventional double-acting press has an hour-glass shape due to an inhomogeneous green density distribution in a powder compact. Thus, a sintered pellet usually undergoes a centerless grinding process in order to secure diametric tolerance specifications. In the case of an annular pellet fabrication using a conventional double-acting press, the same hour-glass shape would probably occur. An inhomogeneous green density distribution in a powder compact is attributed to granule-granule frictions and granule to pressing mold wall frictions. Frictions result in an irregular pressing load distribution in a powder compact. In order to mitigate the frictions, a lot of process variables should be considered such as pre-compaction pressure, lubricant content, granule size and compaction pressure. The purpose of this study is to investigate the effect of a granule size on the amount of deformation after sintering, in other words, the amount of an hour-glassing. The granules with classified size ranges were made to green annular pellets with the same height and diameters. The hour-glassing amounts of the sintered annular pellets were measured and compared with that of the annular pellet made by unclassified granule

  19. Elastic guided wave propagation in a periodic array of multi-layered piezoelectric plates with finite cross-sections.

    Science.gov (United States)

    Cortes, Daniel H; Datta, Subhendu K; Mukdadi, Osama M

    2010-03-01

    In this study, we present a model study of guided wave dispersion and resonance behavior of an array of piezoelectric plates with arbitrary cross-sections. The objective of this work is to analyze the influence of the geometry of an element of a 1D-array ultrasound transducer on generating multi-resonance frequency so as to increase the frequency bandwidth of the transducers. A semi-analytical finite-element (SAFE) method is used to model guided wave propagation in multi-layered 1D-array ultrasound transducers. Each element of the array is composed of LiNbO3 piezoelectric material with rectangular or subdiced cross-section. Four-node bilinear finite-elements have been used to discretize the cross-section of the transducer. Dispersion curves showing the dependence of phase and group velocities on the frequency, and mode shapes of propagating modes were obtained for different geometry consurations. A parametric analysis was carried out to determine the effect of the aspect ratio, subdicing, inversion layer and matching layers on the vibrational behavior of 1D-array ultrasound transducers. It was found that the geometry with subdiced cross-section causes more vibration modes compared with the rectangular section. Modal analysis showed that the additional modes correspond to lateral modes of the piezoelectric subdiced section. In addition, some modes have strong normal displacements, which may influence the bandwidth and the pressure field in front of the transducer. In addition, the dispersion curves reveal strong coupling between waveguide modes due to the anisotropy of the piezoelectric crystal. The effect of the matching layers was to cluster extensional and flexural modes within a certain frequency range. Finally, inversion layer is found to have a minor effect on the dispersion curves. This analysis may provide a means to analyze and understand the dynamic response of 1D-array ultrasound transducers. 2009 Elsevier B.V. All rights reserved.

  20. Comparison of Vector Velocity Imaging using Directional Beamforming and Transverse Oscillation for a Convex Array Transducer

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2014-01-01

    Vector velocity imaging can reveal both the magnitude and direction of the blood velocity. Several techniques have been suggested for estimating the velocity, and this paper compares the performance for directional beamforming and transverse oscillation (TO) vector flow imaging (VFI). Data have b...

  1. Study of a system devoted for ultrasonic non destructive testing of complex geometry pieces using smart contacts transducers

    International Nuclear Information System (INIS)

    Chatillon, S.

    2000-01-01

    This work is devoted to the enhancement of the ultrasonic non destructive testing in contact of nuclear components with complex geometry. In service inspections of such components performed with conventional probes present limited performances: variations in sensitivity, due to unmatched contact, incorrect characterization of the defect, because of the disorientations of the transducer during its displacement, and uncovered scan area when the geometry of the components disturbs the displacement of the transducer. We propose a new concept of smart transducer to improve the performances of such inspections. The radiating surface is flexible to optimize the sensitivity of the testing. Using the measure of the radiating surface distortion, performed by a specific instrumentation, phased array techniques allow the control of the transmitted beam to optimize the defect localization and characterization. Thus, this system is self-contained. We present the different steps involved to develop this system and its experimental validation. A computing model is extended to predict the field transmitted by a flexible contact transducer. This model is used to optimize the radiating surface of a jointed transducer. A delay law optimizing algorithm is developed to ensure the control of the transmitted beam. At last, a method and the associated instrumentation designed to measure the radiating surface distortion are proposed. Experimental Measures in the through-transmission mode validate the ability of this system to control the field transmitted through complex interfaces. At last, inspections in the pulse-echo mode are performed on a specimen with an irregular profile, representative of a real component inspected on site, and artificial embedded reflectors. Two control configurations are used. In the first one, the transducer is displaced along the surface, in the second one, the transducer is fixed and the region of interest is scanned using beam steering. The results show that

  2. Signals analysis of fluxgate array for wire rope defaults

    International Nuclear Information System (INIS)

    Gu Wei; Chu Jianxin

    2005-01-01

    In order to detecting the magnetic leakage fields of the wire rope defaults, a transducer made up of the fluxgate array is designed, and a series of the characteristic values of wire rope defaults signals are defined. By processing the characteristic signals, the LF or LMA of wire rope are distinguished, and the default extent is estimated. The experiment results of the new method for detecting the wire rope faults are introduced

  3. 2D capacitive micromachined ultrasound transducer using novel tiling based on silicon frame

    Science.gov (United States)

    Kim, Youngil; Cho, Kyungil; Kim, Baehyung; Lee, Seungheun; Jeon, Taeho; Song, Jongkeun

    2013-03-01

    In this study, we showed the new transducer and probe integration of 2D ultrasound probe using cMUT. cMUT ultrasound probe having 8192 elements is assembled with tiling frame. Flip chip bonded cMUT-ASIC tiles were arrayed along 2×8 directions to enlarge lateral aperture. Tiling gap between two tiles was under 100μm. RTV layer that has 1mm thick is used in 2-D probe system as a lens and protection layer. Thermal module is also analyzed by using the thermal network analysis, which is realized with the air fans and the fins. Designed PCB circuit for tiling module which is considered with cooling spread concept is 5cm × 5cm dimension. Uniformity and performance of tiled ultrasound transducer were tested under soybean oil at 3MHz frequency successfully. The measured 256 elements distribution has only 4.45% deviation. If we can remove the side edge error, the deviation will be under 3%. The performance after RTV lensing showed 35% attenuation in Tx and 35~45% attenuation in Rx.

  4. Coupling in reflector arrays

    DEFF Research Database (Denmark)

    Appel-Hansen, Jørgen

    1968-01-01

    In order to reduce the space occupied by a reflector array, it is desirable to arrange the array antennas as close to each other as possible; however, in this case coupling between the array antennas will reduce the reflecting properties of the reflector array. The purpose of the present communic......In order to reduce the space occupied by a reflector array, it is desirable to arrange the array antennas as close to each other as possible; however, in this case coupling between the array antennas will reduce the reflecting properties of the reflector array. The purpose of the present...

  5. Ultrathin plasmonic quarter waveplate using broken rectangular annular metasurface

    Science.gov (United States)

    Zhu, Aijiao; Qian, Qinyu; Yan, Ying; Hu, Jingpei; Zhao, Xiaonan; Wang, Chinhua

    2017-07-01

    We propose an ultrathin plasmonic metasurface-enabled quarter waveplate using a subwavelength broken rectangular annulus (BRA) arrays. The BRA structure is formed by two pairs of slits with perpendicular orientation embedded in a silver thin film. The elimination of the overlapping parts at four corners of a regular rectangular annulus increases significantly the phase anisotropy induced by localized surface plasmons, and thus decreases significantly the thickness of the metal film in order to achieve the required phase difference for a designed waveplate. Simulations show that an ultrathin quarter waveplate can be obtained with a as thin as 10 nm thickness of a silver BRA arrays at wavelength band of 1.55 μm which provides great potential in advancing manufacture of nanophotonic devices.

  6. A quarter Wheatstone bridge strain gage force transducer for recording gut motility.

    Science.gov (United States)

    Cowles, V E; Condon, R E; Schulte, W J; Woods, J H; Sillin, L F

    1978-10-01

    Quarter and half Wheatstone bridge extraluminal force transducers for recording of gastrointestinal motility are compared. Modification of the transducer to a quarter bridge is economical, simplifies construction, and improves longevity by eliminating the crossover wire which frequently short circuits. The quarter bridge transducer was found to be as accurate and sensitive as the half bridge transducer.

  7. Determination of hydraulic resistance of rough annular channels by resistance of rough pipes

    Science.gov (United States)

    Korsun, A. S.; Pisarevsky, M. I.; Fedoseev, V. N.; Kreps, M. V.

    2017-11-01

    According to the current calculation recommendations for turbulent flow, coefficient of hydraulic resistance of a smooth annular channel with an equivalent hydraulic diameter dh is assumed to be equal to the coefficient of hydraulic resistance of a pipe with a diameter dh multiplied by a conversion factor. The value of this conversion factor, depending on the Reynolds number and the ratio of the inner diameter of the annular channel to the outer diameter, varies from 1 to 1.07. That is, a smooth annular channel and a smooth pipe with the same hydraulic diameters have practically the same hydraulic resistance coefficients. In this paper, experiments were conducted to test the feasibility of such an approach to channels with rough walls. According to measurements of water flow and pressure gradient, the coefficients of hydraulic resistance of a rough annular channel and a pipe with hydraulic diameters dh = 6 mm were calculated and compared. A trapezoidal artificial roughness was applied to the surfaces, which are flowing with a liquid. The experiments were carried out on a water circuit in the Reynolds number range from 103 to 105 in the regime of full roughness. The obtained experimental results were compared with calculations of coefficients of hydraulic resistance of pipes with artificial roughness according to the existing recommendations. Conclusions are drawn on the possibility of determining the hydraulic resistance of rough annular channels through the resistance of rough pipes.

  8. Numerical and experimental study of an annular pulse tube used in the pulse tube cooler

    Science.gov (United States)

    Pang, Xiaomin; Chen, Yanyan; Wang, Xiaotao; Dai, Wei; Luo, Ercang

    2017-12-01

    Multi-stage pulse tube coolers normally use a U-type configuration. For compactness, it is attractive to build a completely co-axial multi-stage pulse tube cooler. In this way, an annular shape pulse tube is inevitable. Although there are a few reports about previous annular pulse tubes, a detailed study and comparison with a circular pulse tube is lacking. In this paper, a numeric model based on CFD software is carried out to compare the annular pulse tube and circular pulse tube used in a single stage in-line type pulse tube cooler with about 10 W of cooling power at 77 K. The length and cross sectional area of the two pulse tubes are kept the same. Simulation results show that the enthalpy flow in the annular pulse tube is lower by 1.6 W (about 11% of the enthalpy flow) compared to that in circular pulse tube. Flow and temperature distribution characteristics are also analyzed in detail. Experiments are then conducted for comparison with an in-line type pulse tube cooler. With the same acoustic power input, the pulse tube cooler with a circular pulse tube obtains 7.88 W of cooling power at 77 K, while using an annular pulse tube leads to a cooling power of 7.01 W, a decrease of 0.9 W (11.4%) on the cooling performance. The study sets the basis for building a completely co-axial two-stage pulse tube cooler.

  9. Slug to annular flow transition during boiloff in a rod bundle under high-pressure conditions

    International Nuclear Information System (INIS)

    Osakabe, Masahiro; Koizumi, Yasuo; Yonomoto, Taisuke; Kumamaru, Hiroshige; Tasaka, Kanji

    1986-01-01

    High-pressure boiloff experiments in a wide range of bundle powers by using the Two-Phase Flow Test Facility (TPTF) were conducted. Two kinds of boiloff patterns were observed in these experiments. One is the boiloff pattern in a low bundle power, in which the dryout points of rods locate at a certain elevation in the bundle because the mixture level controls the dryout points. The other is the boiloff pattern in a high bundle power, in which the clear mixture level can not be observed and the dryout points of rods locate in a wide range of vertical directions. The vertical scatter of the dryout points is considered to be due to the break of the thin water film on the heater rods under the annular flow pattern. A simple model to predict the slug to annular flow transition in the rod bundle is proposed. In the model, the slug to annular flow transition takes place when the interferences of the water films on the neighboring rods cease. The model appeares to give good predictions of the previous flow transition experiment conducted in a rod bundle. The slug-annular transition below the dryout points was predicted with the present model in the high power boiloff experiments of TPTF. No slug-annular transition below the dryout points is predicted with the present model in the low power boiloff experiments. (orig.)

  10. Hydraulic study of drilling fluid flow in circular and annular tubes

    Energy Technology Data Exchange (ETDEWEB)

    Scheid, C.M.; Calcada, L.A.; Braga, E.R.; Paraiso, E.C.H. [Universidade Federal Rural do Rio de Janeiro (PPGEQ/UFRRJ), Seropedica, RJ (Brazil). Programa de Pos-Graduacao em Engenharia Quimica. Dept. de Engenharia Qumica], E-mail: calcada@ufrrj.br; Martins, A. L. [Petroleo Brasileiro S.A. (CENPES/PETROBRAS), Rio de Janeiro, RJ (Brazil). Centro de Pesquisas

    2011-10-15

    This study investigates the drilling fluid flow behavior of two water-based drilling fluids in circular and annular tubes. The study has four main objectives: 1) to evaluate correlations between the Power Law and the Casson rheological models, 2) to characterize the flow behavior, 3) to evaluate five hydraulic-diameter equations, and 4) to evaluate the correlations of five turbulent flow-friction factors. The experimental fluid flow loop consisted of one positive displacement pump of 25 HP connected to a 500-liter tank agitated by a 3-HP mixer. The fluids passed through six meters long tubes, arranged in three horizontal rows with independent inlets and outlets. The circular tubes had a 1 inch diameter and were configured as two concentric annular tubes. Annular Tube I had an outer diameter of 1 1/4 inch and an inner diameter of 1/2 inch. Annular Tube II had an outer diameter of 2 inches and an inner diameter of 3/4 inch. The results show that, for the fluids in exam, correlations proposed in the literature were inaccurate as far as predicting hydraulic diameter, estimating pressure drop, and defining the flow regime. In general, the performance of those correlations depended on the fluid properties and on the system's geometry. Finally, literature parameters for some of the correlations were estimated for the two drilling fluids studied. These estimations improved the predictive capacity of calculating the friction factor for real drilling fluids applications for both circular and annular tubes. (author)

  11. Design of Optimal Directional Parametric Acoustic Arrays in Air

    Science.gov (United States)

    Garner, Glenwood, III

    The nonlinear interaction of propagating acoustic waves in air is exploited as a means of generating highly directional sound beams at both audio frequencies and ultrasonic frequencies. A solution for the third-order intermodulation (IM3) products generated by the nonlinearity of air with a two-tone source waveform is derived by using cascaded secondorder nonlinearities. This method is applied to collinear sources as well as noncollinear sources. With collinear sources, the third-order interaction of two ultrasonic primary tones, where one is approximately the second harmonic of the other, produces an IM3 tone in the audio band. This IM3 tone is shown both theoretically and experimentally to have greater directivity than the difference tone produced by a traditional parametric array which utilizes second-order effects. With noncollinear sources, the third-order interaction of two ultrasonic primary tones closely spaced in frequency produces IM3 upper and IM3 lower tones that are also closely spaced in frequency to the primary tones. The IM3 upper and IM3 lower tones are shown both theoretically and experimentally to have greater directivity than either of the primary tones. Third-order intermodulation distortion generated by the electronic amplifiers and piezoelectric transducers is also shown to contribute to the third-order intermodulation products generated by air. The nonlinear contributions of the amplifier and transducer are modeled using power series expansions and measurements are performed to determine the power series coefficients. A new geometry for the optimum placement of ultrasonic transducers in a multi-element array is derived using the genetic algorithm and results in sparsely packed transducer elements. For primary ultrasonic tones closely spaced in frequency, the sparsely packed array is shown both theoretically and experimentally to produce a difference tone with greater directivity than obtained with a traditional densely packed hexagonal array

  12. A Guided Ultrasonic Waves Array for Structural Integrity Monitoring

    Science.gov (United States)

    Fromme, P.; Wilcox, P. D.; Lowe, M.; Cawley, P.

    2005-04-01

    Constant, long-term monitoring of large plate-like structures, e.g., oil storage tanks, can be performed using permanently attached remote sensors. A guided ultrasonic waves array, consisting of piezoelectric transducer elements for the excitation and reception of the first antisymmetric Lamb wave mode A0, has been designed and built. Laboratory measurements for a steel plate containing various defects have been performed. The results are compared to theoretical predictions and the sensitivity of the array device for defect detection is ascertained.

  13. Phased-array radar for airborne systems

    Science.gov (United States)

    Tahim, Raghbir S.; Foshee, James J.; Chang, Kai

    2003-09-01

    Phased array antenna systems, which support high pulse rates and high transmit power, are well suited for radar and large-scale surveillance. Sensors and communication systems can function as the eyes and ears for ballistic missile defense applications, providing early warning of attack, target detection and identification, target tracking, and countermeasure decision. In such applications, active array radar systems that contain solid-state transmitter sources and low-noise preamplifiers for transmission and reception are preferred over the conventional radar antennas, because the phased array radar offers the advantages of power management and efficiency, reliability, signal reception, beam steering target detection. The current phased array radar designs are very large, complex and expensive and less efficient because of high RF losses in the phase control circuits used for beam scan. Several thousands of phase shifters and drivers may be required for a single system thus making the system very complex and expensive. This paper describes the phased array radar system based on high power T/R modules, wide-band radiating planar antenna elements and very low loss wide-band phase control circuits (requiring reduced power levels) for beam scan. The phase shifter design is based on micro-strip feed lines perturbed by the proximity of voltage controlled piezoelectric transducer (PET). Measured results have shown an added insertion loss of less than 1 dB for a phase shift of 450 degrees from 2 to 20 GHz. The new wideband phased array radar design provides significant reduction in size cost and weight. Compared to the conventional phased array systems, the cost saving is more than 15 to 1.

  14. Enhancing VVER annular proliferation resistance fuel with minor actinides

    International Nuclear Information System (INIS)

    Chang, G. S.

    2007-01-01

    to the reactivity control of the systems into which they are incorporated. In the study, a typical pressurized water reactor (PWR) VVER-1000 annular fuel unit lattice cell model with UO 2 fuel pins will be used to investigate the effectiveness of minor actinide reduction approach (MARA) for enhancing proliferation resistance and improving the fuel cycle performance in the intermediate term goal for future nuclear energy systems

  15. Curved-array-based multispectral photoacoustic imaging of human finger joints.

    Science.gov (United States)

    Huang, Na; He, Ming; Shi, Haosheng; Zhao, Yuan; Lu, Man; Zou, Xianbing; Yao, Lei; Jiang, Huabei; Xi, Lei

    2017-10-02

    In this study, we present the design, fabrication, and evaluation of a curved-array-based photoacoustic imaging system designed for imaging vasculatures inside human finger joints with multispectral strategy. The transducers was fabricated with polyvinylidene fluoride (PVDF) film with a size of 30 mm×2.8 mm, and a curvature radius of 82 mm. A detailed comparison between the PVDF transducer and commercial piezoelectric ceramic (PTZ) transducers was performed. In addition, phantom and in vivo mouse experiments were carried out to evaluate the system performance. Furthermore, we recruited healthy volunteers and did multispectral photoacoustic imaging of blood vessels in finger joints. The transducers have an average center frequency of 6.6 MHz, and a mean bandwidth of 95%. The lateral and axial resolutions of the system are 110 μm and 800 μm, respectively, and the diameter of the active imaging is larger than 50 mm. We successfully captured the drug-induced cerebral bleeding spots in intact mouse brains, and recovered both morphology and oxygen saturation of the blood vessels in human finger joints. The PVDF transducer has a better performance in bandwidth compared with commercial transducers. The curved design of the transducer offers a better sensitivity and a higher axial resolution compared with the flat design. Based on the phantom, animal and human experiments, the proposed system has the potential to be used in clinical diagnosis of early-stage arthritis.

  16. Vibration characterisation of cymbal transducers for power ultrasonic applications

    Science.gov (United States)

    Bejarano, F.; Feeney, A.; Lucas, M.

    2012-08-01

    A Class V cymbal flextensional transducer is composed of a piezoceramic disc or ring sandwiched between two cymbal-shaped shell end-caps. These end-caps act as mechanical transformers to convert high impedance, low radial displacement of the piezoceramic into low impedance, large axial motion of the end-cap. The cymbal transducer was developed in the early 1990's at Penn State University, and is an improvement of the moonie transducer which has been in use since the 1980's. Despite the fact that cymbal transducers have been used in many fields, both as sensors and actuators, due to its physical limitations its use has been mainly at low power intensities. It is only very recently that its suitability for high amplitude and high power applications has been studied, and consequently implementation in this area of research remains undeveloped. This paper employs experimental modal analysis (EMA), vibration response measurements and electrical impedance measurements to characterise two variations of the cymbal transducer design, both aimed at incorporation in ultrasonic cutting devices. The transducers are fabricated using the commercial Eccobond 45LV epoxy adhesive as the bonding agent. The first cymbal transducer is of the classic design where the piezoceramic disc is bonded directly to the end-caps. The second cymbal transducer includes a metal ring bonded to the outer edge of the piezoceramic disc. The reason for the inclusion of this metal ring is to improve the mechanical coupling with the end-caps. This would therefore make this design particularly suitable for power ultrasonic applications, reducing the possibility of debonding at the higher ultrasonic amplitudes. The experimental results demonstrate that the second cymbal design is a significant improvement on the more classic design, allowing the transducer to operate at higher voltages and higher amplitudes, exhibiting a linear response over a practical power ultrasonic device driving voltage range. The

  17. Numerical Investigation of Effect of Parameters on Hovering Efficiency of an Annular Lift Fan Aircraft

    Directory of Open Access Journals (Sweden)

    Yun Jiang

    2016-10-01

    Full Text Available The effects of various parameters on the hovering performance of an annular lift fan aircraft are investigated by using numerical scheme. The pitch angle, thickness, aspect ratio (chord length, number of blades, and radius of duct inlet lip are explored to optimize the figure of merit. The annular lift fan is also compared with a conventional circular lift fan of the same features with the same disc loading and similar geometry. The simulation results show that the pitch angle of 27°, the thickness of 4% chord length, the aspect ratio of 3.5~4.0, 32 blades, and the radius of inlet lip of 4.7% generate the maximum figure of merit of 0.733. The optimized configuration can be used for further studies of the annular lift fan aircraft.

  18. A rare cause of proximal intestinal obstruction in adults - annular pancreas: a case report.

    Science.gov (United States)

    Mahdi, Bouassida; Selim, Sassi; Hassen, Touinsi; Mongi, Mighri Mohamed; Fadhel, Chtourou Mohamed; Fathi, Chebbi; Sadok, Sassi

    2011-01-01

    Annular pancreas is a rare congenital anomaly characterized by the presence of ectopic pancreatic tissue surrounding the descending part of the duodenum. It is one of the few congenital anomalies of the gastrointestinal tract which can produce symptoms late in life. In adults, the factors initiating symptoms are recurrent pancreatitis, duodenal stenosis at the site of the annulus, or duodenal or gastric ulceration. We report a new case involving a 24-year-old woman hospitalised for epigastric pain, nausea and vomiting. Radiological examination was consisted with an annular pancreas. At operation a complete obstruction of the second part of the duodenum was found, caused by an annular pancreas, no other congenital anomaly of the intra-abdominal organs was noted. A gastroenterostomy was performed.

  19. A rare cause of proximal intestinal obstruction in adults: annular pancreas: a case report

    Directory of Open Access Journals (Sweden)

    Bouassida Mahdi

    2011-12-01

    Full Text Available Annular pancreas is a rare congenital anomaly characterized by the presence of ectopic pancreatic tissue surrounding the descending part of the duodenum. It is one of the few congenital anomalies of the gastrointestinal tract which can produce symptoms late in life. In adults, the factors initiating symptoms are recurrent pancreatitis, duodenal stenosis at the site of the annulus, or duodenal or gastric ulceration. We report a new case involving a 24-year-old woman hospitalised for epigastric pain, nausea and vomiting. Radiological examination was consisted with an annular pancreas. At operation a complete obstruction of the second part of the duodenum was found, caused by an annular pancreas, no other congenital anomaly of the intra-abdominal organs was noted. A gastroenterostomy was performed.

  20. Remodeling Mitral Annuloplasty Ring Concept with Preserved Dynamics of Annular Height

    DEFF Research Database (Denmark)

    Skov, Søren N; Røpcke, Diana M; Tjørnild, Marcell J

    2017-01-01

    BACKGROUND: The configuration of the native annulus changes from nearly flat in the diastolic phase to saddle-shaped in the systolic phase. The present study was conducted to test a novel remodeling annuloplasty ring with built-in septal-lateral fixation and commissural axial flexibility so...... as to maintain the change in annular saddle shape. The study aim was to evaluate the in-vivo biomechanical performance of the novel annuloplasty ring, compared with the native valve and a semi-rigid and rigid annuloplasty ring. METHODS: All measurements were performed in vivo using a porcine model. A total of 28....... The change and maximum value of the annular height were maintained for the novel ring but were significantly decreased for the rigid and semi-rigid rings compared with the 'no-ring' group. Mitral annular force measurements confirmed that the overall remodeling capacity of the novel ring was comparable...

  1. Hydrodynamic stability of inverted annular flow in an adiabatic simulation. [PWR; BWR

    Energy Technology Data Exchange (ETDEWEB)

    De Jarlais, G.; Ishii, M.; Linehan, J.

    1983-01-01

    In experiments, inverted annular flow was simulated adiabatically with turbulent water jets, issuing downward from long aspect nozzles, enclosed in gas annuli. Velocities, diameters, and gas species were varied, and core jet length, shape, break-up mode, and dispersed-core droplet sizes were recorded at approximately 750 data points. Inverted annular flow was observed to develop into inverted slug flow at low relative velocities, and into dispersed droplet flow at high relative velocities. For both of the above transitions from inverted annular flow, a correlation for core jet length was developed by extending work done on free liquid jets to include this new, coaxial, jet disintegration phenomenon. The result, showing length dependence upon diameter, jet Reynolds number, jet Weber number, void fraction, and gas Weber number, correlates the data well, especially at moderate-to-large relative velocities.

  2. Nonparaxial propagation and focusing properties of azimuthal-variant vector fields diffracted by an annular aperture.

    Science.gov (United States)

    Gu, Bing; Xu, Danfeng; Pan, Yang; Cui, Yiping

    2014-07-01

    Based on the vectorial Rayleigh-Sommerfeld integrals, the analytical expressions for azimuthal-variant vector fields diffracted by an annular aperture are presented. This helps us to investigate the propagation behaviors and the focusing properties of apertured azimuthal-variant vector fields under nonparaxial and paraxial approximations. The diffraction by a circular aperture, a circular disk, or propagation in free space can be treated as special cases of this general result. Simulation results show that the transverse intensity, longitudinal intensity, and far-field divergence angle of nonparaxially apertured azimuthal-variant vector fields depend strongly on the azimuthal index, the outer truncation parameter and the inner truncation parameter of the annular aperture, as well as the ratio of the waist width to the wavelength. Moreover, the multiple-ring-structured intensity pattern of the focused azimuthal-variant vector field, which originates from the diffraction effect caused by an annular aperture, is experimentally demonstrated.

  3. A cylindrical standing wave ultrasonic motor using bending vibration transducer.

    Science.gov (United States)

    Liu, Yingxiang; Chen, Weishan; Liu, Junkao; Shi, Shengjun

    2011-07-01

    A cylindrical standing wave ultrasonic motor using bending vibration transducer was proposed in this paper. The proposed stator contains a cylinder and a bending vibration transducer. The two combining sites between the cylinder and the transducer locate at the adjacent wave loops of bending vibration of the transducer and have a distance that equal to the half wave length of bending standing wave excited in the cylinder. Thus, the bending mode of the cylinder can be excited by the bending vibration of the transducer. Two circular cone type rotors are pressed in contact to the end rims of the teeth, and the preload between the rotors and stator is accomplished by a spring and nut system. The working principle of the proposed motor was analyzed. The motion trajectories of teeth were deduced. The stator was designed and analyzed with FEM. A prototype motor was fabricated and measured. Typical output of the prototype is no-load speed of 165rpm and maximum torque of 0.45Nm at an exciting voltage of 200V(rms). Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Resonance tracking and vibration stablilization for high power ultrasonic transducers.

    Science.gov (United States)

    Kuang, Y; Jin, Y; Cochran, S; Huang, Z

    2014-01-01

    Resonant frequency shift and electrical impedance variation are common phenomena in the application of high power ultrasonic transducers, e.g. in focused ultrasound surgery and in cutting. They result in low power efficiency and unstable vibration amplitude. To solve this problem, a driving and measurement system has been developed to track the resonance of high power transducers and to stabilise their vibration velocity. This has the ability to monitor the operating and performance parameters of the ultrasonic transducers in real time. The configuration of the system, with its control algorithm implemented in LabVIEW (National Instruments, Newbury, UK), ensures flexibility to suit different transducers and load conditions. In addition, with different programs, it can be utilised as a high power impedance analyser or an instantaneous electrical power measurement system for frequencies in the MHz range. The effectiveness of this system has been demonstrated in detailed studies. With it, high transducer performance at high power can be achieved and monitored in real time. Copyright © 2013. Published by Elsevier B.V.

  5. A Driver for Piezoelectric Transducers with Control of Resonance

    Science.gov (United States)

    Arnold, F. J.; Ximenes, R. L.; Arthur, R.; Mühlen, S. S.

    Variations in electric impedance curves of piezoeletric transducers occur under influence of mechanical load, temperature, electric excitation, among others. Electronic circuits for driving these transducers should correct the tune to maintain the performance of the transducer. Considering the changes at resonance, we have developed a circuit for a laboratory bench that performs two functions. The first, working on low power, by swapping frequencies around resonance, allows to the user define electric impedance and frequency operation that intend to apply in the experiment. The operation of this circuit is based on detection of magnitude of current in the transducer. A microcontroller and Labview are used to obtain the results. In the second, while under high power operation, deviations from original impedance are corrected by using a feedback network that evaluates amplitude of impedance. In this circuit, a class D MOSFET amplifier is used for exciting the transducer. Also, a microcontroller system controls the feedback network. Experiments with variation of mechanical loads have shown the effectiveness of the system.

  6. Adaptive HIFU noise cancellation for simultaneous therapy and imaging using an integrated HIFU/imaging transducer

    International Nuclear Information System (INIS)

    Jeong, Jong Seob; Cannata, Jonathan Matthew; Shung, K Kirk

    2010-01-01

    It was previously demonstrated that it is feasible to simultaneously perform ultrasound therapy and imaging of a coagulated lesion during treatment with an integrated transducer that is capable of high intensity focused ultrasound (HIFU) and B-mode ultrasound imaging. It was found that coded excitation and fixed notch filtering upon reception could significantly reduce interference caused by the therapeutic transducer. During HIFU sonication, the imaging signal generated with coded excitation and fixed notch filtering had a range side-lobe level of less than -40 dB, while traditional short-pulse excitation and fixed notch filtering produced a range side-lobe level of -20 dB. The shortcoming is, however, that relatively complicated electronics may be needed to utilize coded excitation in an array imaging system. It is for this reason that in this paper an adaptive noise canceling technique is proposed to improve image quality by minimizing not only the therapeutic interference, but also the remnant side-lobe 'ripples' when using the traditional short-pulse excitation. The performance of this technique was verified through simulation and experiments using a prototype integrated HIFU/imaging transducer. Although it is known that the remnant ripples are related to the notch attenuation value of the fixed notch filter, in reality, it is difficult to find the optimal notch attenuation value due to the change in targets or the media resulted from motion or different acoustic properties even during one sonication pulse. In contrast, the proposed adaptive noise canceling technique is capable of optimally minimizing both the therapeutic interference and residual ripples without such constraints. The prototype integrated HIFU/imaging transducer is composed of three rectangular elements. The 6 MHz center element is used for imaging and the outer two identical 4 MHz elements work together to transmit the HIFU beam. Two HIFU elements of 14.4 mm x 20.0 mm dimensions could

  7. Complete annular and partial oblique pulley release for pediatric locked trigger thumb.

    Science.gov (United States)

    Kuo, Meiying; Rayan, Ghazi M

    2010-12-01

    To report the surgical treatment outcome of pediatric locked trigger thumb by sequential release of the annular pulley and partial release of the oblique pulley. A retrospective review was undertaken on 28 operative thumbs in 24 patients with an average follow-up of 79 months. Intraoperative observations focused on the pathology of the pulley system. Surgical technique involved complete release of the annular pulley, which alone was insufficient in relieving the deformity, along with release of the proximal 50% of the oblique pulley in all patients. Postoperative parameters of bowstringing, resolution of Notta's node, thumb interphalangeal motion, and patient/parent satisfaction were assessed. The oblique pulley appeared stenotic, whereas the annular pulley was observed to be membranous and nearly indistinguishable from the tendon sheath. No patients had recurrence of thumb locking or triggering. No bowstringing was detected, and Notta's node resolved fully in 19 of 20 thumbs. Five thumbs had an average of 12(o) less active IP joint motion without flexion contracture (i.e., less flexion). All patients or families expressed overall satisfaction with the procedure. The annular pulley was attenuated in the majority of cases and the proximal half of the oblique pulley was stenotic in all patients. Releasing 50% of the oblique pulley after complete annular pulley release was necessary in all thumbs to achieve full FPL excursion. Mistaking the constricted proximal oblique pulley for an annular pulley may encourage releasing the entire oblique pulley, leading to an adverse result. Satisfactory outcome was achieved after surgical treatment of pediatric locked trigger thumbs. Therapeutic IV.

  8. Optimization of gap sizes for the high performance of annular nuclear fuels

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Young Doo; Kwon, Soon Bum; Cho, Hui Jeong; Kim, Seong Su [Kyungpook National University, Daegu (Korea, Republic of)

    2015-04-15

    Solid-type nuclear fuels have been used for nuclear reactors for a long time. Many countries are currently developing annular fuels to improve the efficiency of nuclear fuels. The thermoelastic-plastic-creep analyses of solid- and annular-type rods were conducted under the same conditions. The temperature and stress of the solid- and annular-type rods were compared on the basis of gap size. In this study, we examined the advantages and disadvantages of annular-type fuel regarding the temperature and stress of the pellet and cladding. The inner and outer gaps between the pellet and cladding play important roles in the temperature and stress distributions of fuel systems. Therefore, the optimization of gaps in fuel systems was conducted for a low temperature under certain stress conditions. hermoelasticplastic-creep analyses were conducted by using an in-house thermoelastic-plastic-creep finite element analysis program in Visual FORTRAN with the effective stress function algorithm. Nonlinear iterative stress analyses were conducted by nonlinear iterative temperature analyses; that is, a quasi-fully coupled algorithm was applied to this procedure. In this study, the thermoelastic-plastic-creep analysis of pressurized water reactor annular fuels was conducted to determine the contacting tendency of the inner-outer gaps between the annular fuel pellets and cladding, as well as to optimize the gap sizes by using the commercial package PIAnO for efficient heat transfer at certain stress levels. Most analyses were conducted until the gaps disappeared. However, certain analyses lasted for 1582 days, after which the fuels were replaced.

  9. 3-D Deep Penetration Photoacoustic Imaging with a 2-D CMUT Array

    OpenAIRE

    Ma, Te-Jen; Kothapalli, Sri Rajasekhar; Vaithilingam, Srikant; Oralkan, Ömer; Kamaya, Aya; Wygant, Ira O.; Zhuang, Xuefeng; Gambhir, Sanjiv S.; Jeffrey, R. Brooke; Khuri-Yakub, Butrus T.

    2010-01-01

    In this work, we demonstrate 3-D photoacoustic imaging of optically absorbing targets embedded as deep as 5 cm inside a highly scattering background medium using a 2-D capacitive micromachined ultrasonic transducer (CMUT) array with a center frequency of 5.5 MHz. 3-D volumetric images and 2-D maximum intensity projection images are presented to show the objects imaged at different depths. Due to the close proximity of the CMUT to the integrated frontend circuits, the CMUT array imaging system...

  10. Fabrication and characterization of a smart epitaxial piezoelectric micromachined ultrasonic transducer

    Energy Technology Data Exchange (ETDEWEB)

    Ozaki, Katsuya [Department of Electrical and Electronic Information Engg, Toyohashi University of Technology, Toyohashi, Aichi 441-8580 (Japan); Matin, Abdul, E-mail: matin.md.a@gmail.com [Department of Glass and Ceramic Engineering, Bangladesh University of Engg and Tech (BUET), Dhaka 1000 (Bangladesh); Numata, Yasuyuki [Department of Electrical and Electronic Information Engg, Toyohashi University of Technology, Toyohashi, Aichi 441-8580 (Japan); Akai, Daisuke [Electronics-Inspired Interdisciplinary Research Institute (EIIRIS), Toyohashi University of Technology Toyohashi, Toyohahsi, Aichi 441-8580 (Japan); Sawada, Kazuaki; Ishida, Makoto [Department of Electrical and Electronic Information Engg, Toyohashi University of Technology, Toyohashi, Aichi 441-8580 (Japan); Electronics-Inspired Interdisciplinary Research Institute (EIIRIS), Toyohashi University of Technology Toyohashi, Toyohahsi, Aichi 441-8580 (Japan)

    2014-12-15

    Highlights: • Highly [1 1 1] orientated functional PZT(1 1 1) thin film was grown on n-Si(1 1 1)/γ-Al{sub 2}O{sub 3}(1 1 1)/SrRuO{sub 3}(1 1 1). • Device performance of pMUT was studied using both experiment and modeling. • Material anisotropy played a significant role in the shifting of resonant frequency • pMUT shows high sensitivity for the transmission of ultrasonic pulses. • Successful realization of a piezoelectric ultrasonic transducer (pMUT) array. - Abstract: A novel piezoelectric micromachined ultrasonic transducer (pMUT) array was designed and fabricated using epitaxially grown functional Pb(Zr{sub 0.52}Ti{sub 0.48})O{sub 3} (PZT) thin film on Si(1 1 1)/γ-Al{sub 2}O{sub 3}(1 1 1)/SrRuO{sub 3}(1 1 1) substrate for biomedical applications. The crystallographic orientation of PZT film was controlled by the incorporation of epitaxial γ-Al{sub 2}O{sub 3} film on Si substrate. Modal shape of pMUT was analyzed employing advanced 3D finite element modeling taking the crystallographic anisotropy of materials and the properties of immersed medium (air or water) into account. Eigenfrequency with mode shapes has shown to have significant influence on transmitting-receiving characteristics of pMUT. Modal shapes of pMUT were also quantitatively determined using Laser Doppler Vibratometry (LDV). An excellent correlation was obtained between computational and experimental results. A significantly high sensitivity of 3.9 μV/kPa was obtained in an under-water ultrasonic wave transmission experiment conducted using fabricated pMUT as wave transmitter and a commercial transducer as receiver at a fundamental frequency of 1.20 MHz. Advanced FE computation thus serves as a tool to a priori optimize device structure for the successful transmission of ultrasonic waves with sufficient power to generate high resolution 3D imaging.

  11. Numerical Investigation of Effect of Parameters on Hovering Efficiency of an Annular Lift Fan Aircraft

    OpenAIRE

    Yun Jiang; Bo Zhang

    2016-01-01

    The effects of various parameters on the hovering performance of an annular lift fan aircraft are investigated by using numerical scheme. The pitch angle, thickness, aspect ratio (chord length), number of blades, and radius of duct inlet lip are explored to optimize the figure of merit. The annular lift fan is also compared with a conventional circular lift fan of the same features with the same disc loading and similar geometry. The simulation results show that the pitch angle of 27°, the th...

  12. Displacement of one Newtonian fluid by another: density effects in axial annular flow

    DEFF Research Database (Denmark)

    Szabo, Peter; Hassager, Ole

    1997-01-01

    The arbitrary Lagrange-Euler (ALE) finite elementtechnique is used to simulate 3D displacement oftwo immiscible Newtonian fluids in vertical annular wells. For equally viscous fluids the effect of distinct fluid densities is investigated in the region of low to intermediate Reynolds numbers....... Comparison with a simple theory for drainage of thin films is performed. It is found that recirculations deform the fluid-fluidinterface significantly in situations dominated by buoyancy forces. Also, a deviation from the concentric annular geometry is shown to induce azimuthal transport of fluid. Finally......, the efficiency of the displacement is analysed for various flow situations....

  13. Studying laminar flows of power-law fluids in the annular channel with eccentricity

    Science.gov (United States)

    Zhigarev, V. A.; Neverov, A. L.; Guzei, D. V.; Pryazhnikov, M. I.

    2017-09-01

    The paper deals with numerical and experimental investigation of non-Newtonian flow of modeling drilling fluids in the annular channel. The Reynolds number was ranged from 100 to 1500. The parameters of the power-law model of drilling fluids were varied within the following ranges: n = 0.43-0.49, K = 0.22-0.89. The eccentricity was changed from 0 to 1. We have measured pressure drop in the annular channel and compared calculations with experimental data, achieving good agreement between calculations and experiment.

  14. Generation of annular, high-charge electron beams at the Argonne wakefield accelerator

    Science.gov (United States)

    Wisniewski, E. E.; Li, C.; Gai, W.; Power, J.

    2013-01-01

    We present and discuss the results from the experimental generation of high-charge annular(ring-shaped)electron beams at the Argonne Wakefield Accelerator (AWA). These beams were produced by using laser masks to project annular laser profiles of various inner and outer diameters onto the photocathode of an RF gun. The ring beam is accelerated to 15 MeV, then it is imaged by means of solenoid lenses. Transverse profiles are compared for different solenoid settings. Discussion includes a comparison with Parmela simulations, some applications of high-charge ring beams,and an outline of a planned extension of this study.

  15. Near-limit propagation of gaseous detonations in narrow annular channels

    Science.gov (United States)

    Gao, Y.; Ng, H. D.; Lee, J. H. S.

    2017-03-01

    New results on the near-limit behaviors of gaseous detonations in narrow annular channels are reported in this paper. Annular channels of widths 3.2 and 5.9 mm were made using circular inserts in a 50.8 mm-diameter external tube. The length of each annular channel was 1.8 m. Detonations were initiated in a steel driver tube where a small volume of a sensitive C2H2+ 2.5O2 mixture was injected to facilitate detonation initiation. A 2 m length of circular tube with a 50.8 mm diameter preceded the annular channel so that a steady Chapman-Jouguet (CJ) detonation was established prior to entering the annular channel. Four detonable mixtures of C2H2 {+} 2.5O2 {+} 85 % Ar, C2H2 {+} 2.5O2 {+} 70 % Ar, C3H8 {+} 5O2, and CH4 {+} 2O2 were used in the present study. Photodiodes spaced 10 cm throughout the length of both the annular channel and circular tube were used to measure the detonation velocity. In addition, smoked foils were inserted into the annular channel to monitor the cellular structure of the detonation wave. The results show that, well within the detonability limits, the detonation wave propagates along the channel with a small local velocity fluctuation and an average global velocity can be deduced. The average detonation velocity has a small deficit of 5-15 % far from the limits and the velocity rapidly decreases to 0.7V_{CJ}-0.8V_{CJ} when the detonation propagates near the limit. Subsequently, the fluctuation of local velocity also increases as the decreasing initial pressure approaches the limit. In the two annular channels used in this work, no galloping detonations were observed for both the stable and unstable mixtures tested. The present study also confirms that single-headed spinning detonation occurs at the limit, as in a circular tube, rather than the up and down "zig zag" mode in a two-dimensional, rectangular channel.

  16. DETERMINATION OF TEMPERATURE DISTRIBUTION FOR ANNULAR FINS WITH TEMPERATURE DEPENDENT THERMAL CONDUCTIVITY BY HPM

    Directory of Open Access Journals (Sweden)

    Davood Domairry Ganji

    2011-01-01

    Full Text Available In this paper, homotopy perturbation method has been used to evaluate the temperature distribution of annular fin with temperature-dependent thermal conductivity and to determine the temperature distribution within the fin. This method is useful and practical for solving the nonlinear heat transfer equation, which is associated with variable thermal conductivity condition. The homotopy perturbation method provides an approximate analytical solution in the form of an infinite power series. The annular fin heat transfer rate with temperature-dependent thermal conductivity has been obtained as a function of thermo-geometric fin parameter and the thermal conductivity parameter describing the variation of the thermal conductivity.

  17. Quantitative experiments on thermal hydraulic characteristics of an annular tube with twisted fins

    International Nuclear Information System (INIS)

    Ezato, Koichiro; Dairaku, Masayuki; Taniguchi, Masaki; Sato, Kazuyoshi; Suzuki, Satoshi; Akiba, Masato

    2003-11-01

    Thermal hydraulic experiments measuring critical heat flux (CHF) and pressure drop of an annular tube with twisted fins, ''annular swirl tube'', has been performed to examine its applicability to the ITER divertor cooling structure. The annular swirl tube consists of two concentric circular tubes, the outer and inner tubes. The outer tube with outer and inner diameters (OD and ID) of 21 mm and 15 mm is made of Cu-alloy that is CuCrZr and oe of candidate materials of the ITER divertor cooling tube. The inner tube with OD of 11 mm and ID of 9 mm is made of stainless steal. It has an external swirl fin with twist ratio (y) of three to enhance its heat transfer performance. In this tube, cooling water flows inside of the inner tube first, and then returns into an annulus between the outer and inner tubes with a swirl flow at an end-return of the cooling tube. The CHF experiments show that no degradation of CHF of the annular swirl tube in comparison with the conventional swirl tube whose dimensions are similar to those of the outer tube of the annular swirl tube. A minimum axial velocity of 7.1 m/s is required to remove the incident heat flux of 28MW/m 2 , the ITER design value. Applicability of the JAERI's correlation for the heat transfer to the annular swirl tube is also demonstrated by comparing the experimental results with those of the numerical analysis. The friction factor correlation for the annular flow with the twisted fins is also proposed for the hydrodynamic design of the ITER vertical target. The least pressure drop at the end-return is obtained by using the hemispherical end-plug. Its radius is the same as that of ID of the outer cooling tube. These results show that thermal-hydraulic performance of the annular swirl tube is promising in application to the cooling structure for the ITER vertical target. (author)

  18. Dynamics of annular bright field imaging in scanning transmission electron microscopy

    International Nuclear Information System (INIS)

    Findlay, S.D.; Shibata, N.; Sawada, H.; Okunishi, E.; Kondo, Y.; Ikuhara, Y.

    2010-01-01

    We explore the dynamics of image formation in the so-called annular bright field mode in scanning transmission electron microscopy, whereby an annular detector is used with detector collection range lying within the cone of illumination, i.e. the bright field region. We show that this imaging mode allows us to reliably image both light and heavy columns over a range of thickness and defocus values, and we explain the contrast mechanisms involved. The role of probe and detector aperture sizes is considered, as is the sensitivity of the method to intercolumn spacing and local disorder.

  19. Theory versus experiment for the rotordynamic coefficients of annular gas seals. I - Test facility and apparatus

    Science.gov (United States)

    Childs, D. W.; Nelson, C. E.; Nicks, C.; Scharrer, J.; Elrod, D.

    1985-01-01

    A facility and apparatus are described for determining the rotordynamic coefficients and leakage characteristics of annular gas seals. The coefficients and leakage characteristics of annular gas seals. The apparatus has a current top speed of 8000 cpm with a nominal seal diameter of 15.24 cmn (6 in.). The air supply unit yields a seal pressure ratio of approximately 7. An external shaker is used to excite the test rotor. The capability to independently calculate all rotordynamic coefficients at a given operating condition with one excitation frequency are discussed.

  20. Reducing the Effect of Transducer Mount Induced Noise on Aeroacoustic Wind Tunnel Testing Data with a New Transducer Mount Design

    Science.gov (United States)

    Herron, A. J.; Reed, D. K.; Nance, D. K.

    2015-01-01

    Characterization of launch vehicle unsteady aerodynamics is a field best studied through experimentation, which is often carried out in the form of large scale wind tunnel testing. Measurement of the fluctuating pressures induced by the boundary layer noise is customarily made with miniature pressure transducers installed into a model of the vehicle of interest. Literature shows that noise level increases between two to five decibels (dB referenced to 20 micropascal) can be induced when the transducer surface is not mounted perfectly flush with the model outer surface. To reduce this artificially induced noise, special transducer holders have been used for aeroacoustic wind tunnel testing by NASA. This holder is a sleeve into which the transducer fits, with a cap that allows it to be mounted in a recessed hole in the model. A single hole in the holder allows the transport of the tunnel medium so the transducer can discriminate the fluctuating pressure due to the turbulent boundary layer noise. The holder is first dry fitted into the model and any difference in height between the holder and the model surface can be sanded flush. The holder is then removed from the model, the transducer glued inside the holder, and the holder replaced in the model, secured also with glue, thus eliminating the problem of noise level increases due to lack of flushness. In order to work with this holder design, special transducers have been ordered with their standard screen removed and the diaphragm moved as close to the top of the casing as possible to minimize any cavity volume. Although this greatly reduces induced noise due to the transducers being out of flush, the holders can also induce a cavity resonance that is usually at a very high frequency. This noise is termed transducer mount induced noise (XMIN). The peak of the mode can vary with the cavity depth, boundary layer noise that can excite the mode, tunnel flow medium, and the build of the transducers. Because the boundary