WorldWideScience

Sample records for angle changing device

  1. Modified sine bar device measures small angles with high accuracy

    Science.gov (United States)

    Thekaekara, M.

    1968-01-01

    Modified sine bar device measures small angles with enough accuracy to calibrate precision optical autocollimators. The sine bar is a massive bar of steel supported by two cylindrical rods at one end and one at the other.

  2. Torsion angle dependence of the rectifying performance in molecular device with asymmetrical anchoring groups

    International Nuclear Information System (INIS)

    Wang, L.H.; Guo, Y.; Tian, C.F.; Song, X.P.; Ding, B.J.

    2010-01-01

    Using first-principles density functional theory and nonequilibrium Green's function formalism, we investigate the effect of torsion angle on the rectifying characteristics of 4'-thiolate-biphenyl-4-dithiocarboxylate sandwiched between two Au(111) electrodes. The results show that the torsion angle has an evident influence on rectifying performance of such devices. By increasing the dihedral angle between two phenyl rings, namely changing the magnitude of the intermolecular coupling effect, a different rectifying behavior can be observed in these systems. Our findings highlight that the rectifying characteristics are intimately related to dihedral angles and can provide fundamental guidelines for the design of functional molecular devices.

  3. Longitudinal changes of angle configuration in primary angle-closure suspects: the Zhongshan Angle-Closure Prevention Trial.

    Science.gov (United States)

    Jiang, Yuzhen; Chang, Dolly S; Zhu, Haogang; Khawaja, Anthony P; Aung, Tin; Huang, Shengsong; Chen, Qianyun; Munoz, Beatriz; Grossi, Carlota M; He, Mingguang; Friedman, David S; Foster, Paul J

    2014-09-01

    To determine longitudinal changes in angle configuration in the eyes of primary angle-closure suspects (PACS) treated by laser peripheral iridotomy (LPI) and in untreated fellow eyes. Longitudinal cohort study. Primary angle-closure suspects aged 50 to 70 years were enrolled in a randomized, controlled clinical trial. Each participant was treated by LPI in 1 randomly selected eye, with the fellow eye serving as a control. Angle width was assessed in a masked fashion using gonioscopy and anterior segment optical coherence tomography (AS-OCT) before and at 2 weeks, 6 months, and 18 months after LPI. Angle width in degrees was calculated from Shaffer grades assessed under static gonioscopy. Angle configuration was also evaluated using angle opening distance (AOD250, AOD500, AOD750), trabecular-iris space area (TISA500, TISA750), and angle recess area (ARA) measured in AS-OCT images. No significant difference was found in baseline measures of angle configuration between treated and untreated eyes. At 2 weeks after LPI, the drainage angle on gonioscopy widened from a mean of 13.5° at baseline to a mean of 25.7° in treated eyes, which was also confirmed by significant increases in all AS-OCT angle width measures (Pgonioscopy (P = 0.18), AOD250 (P = 0.167) and ARA (P = 0.83). In untreated eyes, angle width consistently decreased across all follow-up visits after LPI, with a more rapid longitudinal decrease compared with treated eyes (P values for all variables ≤0.003). The annual rate of change in angle width was equivalent to 1.2°/year (95% confidence interval [CI], 0.8-1.6) in treated eyes and 1.6°/year (95% CI, 1.3-2.0) in untreated eyes (P<0.001). Angle width of treated eyes increased markedly after LPI, remained stable for 6 months, and then decreased significantly by 18 months after LPI. Untreated eyes experienced a more consistent and rapid decrease in angle width over the same time period. Copyright © 2014 American Academy of Ophthalmology. Published by

  4. Characterization of lipid films by an angle-interrogation surface plasmon resonance imaging device.

    Science.gov (United States)

    Liu, Linlin; Wang, Qiong; Yang, Zhong; Wang, Wangang; Hu, Ning; Luo, Hongyan; Liao, Yanjian; Zheng, Xiaolin; Yang, Jun

    2015-04-01

    Surface topographies of lipid films have an important significance in the analysis of the preparation of giant unilamellar vesicles (GUVs). In order to achieve accurately high-throughput and rapidly analysis of surface topographies of lipid films, a homemade SPR imaging device is constructed based on the classical Kretschmann configuration and an angle interrogation manner. A mathematical model is developed to accurately describe the shift including the light path in different conditions and the change of the illumination point on the CCD camera, and thus a SPR curve for each sampling point can also be achieved, based on this calculation method. The experiment results show that the topographies of lipid films formed in distinct experimental conditions can be accurately characterized, and the measuring resolution of the thickness lipid film may reach 0.05 nm. Compared with existing SPRi devices, which realize detection by monitoring the change of the reflective-light intensity, this new SPRi system can achieve the change of the resonance angle on the entire sensing surface. Thus, it has higher detection accuracy as the traditional angle-interrogation SPR sensor, with much wider detectable range of refractive index. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Parametric Study of the Device Angle Dependency of a Single Vortex Generator on a Flat Plate

    DEFF Research Database (Denmark)

    Fernandez, U.; Réthoré, Pierre-Elouan; Sørensen, Niels N.

    A detailed study of the device angle dependency of a single vortex generator (VG) is presented in this paper. A single Vortex Generator on a test section wall case, with four different positions of the device angle to the incoming flow, has been designed and solved by computational methods...

  6. Longitudinal Changes of Angle Configuration in Primary Angle-Closure Suspects

    Science.gov (United States)

    Jiang, Yuzhen; Chang, Dolly S.; Zhu, Haogang; Khawaja, Anthony P.; Aung, Tin; Huang, Shengsong; Chen, Qianyun; Munoz, Beatriz; Grossi, Carlota M.

    2015-01-01

    Objective To determine longitudinal changes in angle configuration in the eyes of primary angle-closure suspects (PACS) treated by laser peripheral iridotomy (LPI) and in untreated fellow eyes. Design Longitudinal cohort study. Participants Primary angle-closure suspects aged 50 to 70 years were enrolled in a randomized, controlled clinical trial. Methods Each participant was treated by LPI in 1 randomly selected eye, with the fellow eye serving as a control. Angle width was assessed in a masked fashion using gonioscopy and anterior segment optical coherence tomography (AS-OCT) before and at 2 weeks, 6 months, and 18 months after LPI. Main Outcome Measures Angle width in degrees was calculated from Shaffer grades assessed under static gonioscopy. Angle configuration was also evaluated using angle opening distance (AOD250, AOD500, AOD750), trabecular-iris space area (TISA500, TISA750), and angle recess area (ARA) measured in AS-OCT images. Results No significant difference was found in baseline measures of angle configuration between treated and untreated eyes. At 2 weeks after LPI, the drainage angle on gonioscopy widened from a mean of 13.5° at baseline to a mean of 25.7° in treated eyes, which was also confirmed by significant increases in all AS-OCT angle width measures (Pgonioscopy (P = 0.18), AOD250 (P = 0.167) and ARA (P = 0.83). In untreated eyes, angle width consistently decreased across all follow-up visits after LPI, with a more rapid longitudinal decrease compared with treated eyes (P values for all variables ≤0.003). The annual rate of change in angle width was equivalent to 1.2°/year (95% confidence interval [CI], 0.8–1.6) in treated eyes and 1.6°/year (95% CI, 1.3–2.0) in untreated eyes (P<0.001). Conclusions Angle width of treated eyes increased markedly after LPI, remained stable for 6 months, and then decreased significantly by 18 months after LPI. Untreated eyes experienced a more consistent and rapid decrease in angle width over the

  7. Gender angle to the climate change negotiations

    NARCIS (Netherlands)

    Wamukonya, Njeri; Skutsch, Margaret

    2002-01-01

    The South is likely to suffer more from climate change than the North due to its already vulnerable situation and lack of the necessary resources to adapt to change. But do the interests of men and of women differ as regards climate change and does this have a South-North dimension? This paper

  8. Comparison of two spectral domain optical coherence tomography devices for angle-closure assessment.

    Science.gov (United States)

    Quek, Desmond T; Narayanaswamy, Arun K; Tun, Tin A; Htoon, Hla M; Baskaran, Mani; Perera, Shamira A; Aung, Tin

    2012-08-03

    To compare two spectral domain optical coherence tomography (SD-OCT) devices for the identification of angle structures and the presence of angle closure. This was a prospective comparative study. Consecutive patients underwent gonioscopy and anterior segment imaging using two SD-OCT devices (iVue and Cirrus). Images were evaluated for the ability to detect angle structures such as Schwalbe's line (SL), trabecular meshwork (TM), Schlemm's canal (SC), and scleral spur (SS), and the presence of angle closure. Angle closure was defined as iris contact with the angle wall anterior to the SS on SD-OCT, and nonvisibility of the posterior TM on gonioscopy. Angle closure in an eye was defined as ≥two quadrants of closed angles. AC1 statistic was used to assess the agreement between devices. Of the 69 subjects studied (46.4% male, 84.1% Chinese, mean age 64.0 ± 10.5 years), 40 subjects (40 eyes, 58.0%) had angle closure on gonioscopy. The most identifiable structure on Cirrus SD-OCT was the SS (82.2%) and SL on iVue SD-OCT (74.5%). Angle closure was indeterminable in 14.5% and 50.7% of Cirrus and iVue scans (P gonioscopy was only fair (AC1 = 0.35 and 0.50 for Cirrus and iVue, respectively). It was more difficult to determine angle closure status with iVue compared with Cirrus SD-OCT. There was fair agreement between both devices with gonioscopy for identifying angle closure.

  9. The wave vane - A device to measure the breaker angle

    Digital Repository Service at National Institute of Oceanography (India)

    Chandramohan, P.; Nayak, B.U.; Anand, N.M.

    directional wave gauge at a considerable cost. For economic and practical considerations, visual measurements on the breaker height, the breaker period and the breaker angle are generally made in the LEO pro- gramme. The breaker height is recorded... of the fins. Flag masts are fixed on either end of the arms. The whole assembly thus revolves around the spindle resting on the sleeve. WORKING PRINCIPLE The flag masts, two on the revolving arms and one on the top of the spindle lie always in a straight...

  10. Analysis of the changing Solar Radiation Angle on Hainan Island

    Directory of Open Access Journals (Sweden)

    Ge Zhiwu

    2017-01-01

    Full Text Available As the only tropical provinces in China, Hainan province has advantageous geographical location, and abundant solar energy resources. But because of Local ideas and habits, especially the lack of theoretical research on local solar resources, development and application of solar energy in Hainan is almost blank. In this paper, we studied the variation regularity of sunlight angle on Hainan tropical island, analyzed the revolution and rotation of the earth, and the change rule of sunlight angle caused by the sun’s movement between the tropic of cancer and the tropic of capricorn, deduced the change rule of sunlight angle in the spring equinox, the autumnal equinox, summer solstice and winter solstice day, and got the movement rules of solar elevation angle throughout the year. Theoretic analysis is consistent with field measurement results. These rules are of importance and can effectively guide the local People’s daily life and production, such as the reasonable layout of the buildings, floor distance between different heights of buildings, the direction of the lighting windows of tall buildings, installation angle of photovoltaic panels, and other similar solar energy absorbing and conversion equipment.

  11. Device for measuring the angle of repose of materials or goniometer

    Energy Technology Data Exchange (ETDEWEB)

    Depoitier, J [Institut National des Radioelements, Brussels (Belgium); Parisis, J; Rossion, R [Cimenteries CBR Cementbedrijven, Brussels (Belgium)

    1980-01-01

    The slope measuring facility consists essentially of a gamma source (Cobalt 60) positioned in front of the main position of the batter and of two scintillators (NaI crystals) opposite the source. The different absorption values piched up by the two detectors allow to determine the angle of repose of the batter. The device was especially studied for cement kilns.

  12. Development of a large-solid-angle and multi-device detection system for elemental analysis

    International Nuclear Information System (INIS)

    Satoh, T.; Ishii, K.; Kamiya, T.; Sakai, T.; Oikawa, M.; Arakawa, K.; Matsuyama, S.; Yamazaki, H.

    2003-01-01

    A new detection apparatus for both low energy X-rays like 1 keV and back scattered protons of MeV energy was developed. The detection apparatus consists of a large-solid-angle multi-device Si detector and a data acquisition system. The detector has 45 detection devices which are arranged in the shape of a pentagonal pyramid and fully cover a sample. A micro-beam irradiates the sample through the center of the pentagonal pyramid and X-rays emitted from the sample are detected in a solid angle of about 1.0 sr. This novel detection setup has about five times higher sensitivity than a conventional micro-PIXE camera. In addition, not only X-rays but back scattered protons can be detected, since the counting rate of back scattered protons per detection device is small despite lack of a passive absorber

  13. Contact angle change during evaporation of near-critical liquids

    Science.gov (United States)

    Nikolayev, Vadim; Hegseth, John; Beysens, Daniel

    1998-11-01

    An unexpected change of the dynamic contact angle was recently observed in a near-critical liquid-gas system in a space experiment. While the near-critical liquid completely wets a solid under equilibrium conditions, the apparent contact angle changed from 0^circ to about 120^circ during evaporation. We propose an explanation for this phenomenon by taking into account vapor recoil due to evaporation (motion of the vapor from the free liquid surface). This force is normal to the vapor-liquid interface and is directed towards the liquid. It increases sharply near the triple contact line. Near the critical point, where the surface tension force is very weak, the vapor recoil force can be important enough to change the apparent contact angle. A similar effect can also explain the drying of a heater during boiling at high heat flux. The drying greatly reduces the heat transfer to the liquid causing the heater to melt. This phenomenon is called ``boiling crisis", ``burnout" or ``Departure from Nuclear Boiling". We report the preliminary results of the numerical simulation of the liquid evaporation by the Boundary Element method.

  14. Nanoscale phase-change materials and devices

    International Nuclear Information System (INIS)

    Zheng, Qinghui; Wang, Yuxi; Zhu, Jia

    2017-01-01

    Phase-change materials (PCMs) that can reversibly transit between crystalline and amorphous phases have been widely used for data-storage and other functional devices. As PCMs scale down to nanoscale, the properties and transition procedures can vary, bringing both challenges and opportunities in scalability. This article describes the physical structures, properties and applications of nanoscale phase-change materials and devices. The limitations and performance of scaling properties in phase-change materials and the recent progress and challenges in phase-change devices are presented. At the end, some emerging applications related to phase-change materials are also introduced. (topical review)

  15. Nanoscale phase-change materials and devices

    Science.gov (United States)

    Zheng, Qinghui; Wang, Yuxi; Zhu, Jia

    2017-06-01

    Phase-change materials (PCMs) that can reversibly transit between crystalline and amorphous phases have been widely used for data-storage and other functional devices. As PCMs scale down to nanoscale, the properties and transition procedures can vary, bringing both challenges and opportunities in scalability. This article describes the physical structures, properties and applications of nanoscale phase-change materials and devices. The limitations and performance of scaling properties in phase-change materials and the recent progress and challenges in phase-change devices are presented. At the end, some emerging applications related to phase-change materials are also introduced.

  16. A Textile-Based Wearable Sensing Device Designed for Monitoring the Flexion Angle of Elbow and Knee Movements

    Directory of Open Access Journals (Sweden)

    Tien-Wei Shyr

    2014-02-01

    Full Text Available In this work a wearable gesture sensing device consisting of a textile strain sensor, using elastic conductive webbing, was designed for monitoring the flexion angle of elbow and knee movements. The elastic conductive webbing shows a linear response of resistance to the flexion angle. The wearable gesture sensing device was calibrated and then the flexion angle-resistance equation was established using an assembled gesture sensing apparatus with a variable resistor and a protractor. The proposed device successfully monitored the flexion angle during elbow and knee movements.

  17. Breathing pattern and head posture: changes in craniocervical angles.

    Science.gov (United States)

    Sabatucci, A; Raffaeli, F; Mastrovincenzo, M; Luchetta, A; Giannone, A; Ciavarella, D

    2015-04-01

    The aim of this study was to observe the influence of oral breathing on head posture and to establish possible postural changes observing the variation of craniocervical angles NSL/OPT and NSL/CVT between oral breathing subjects and physiological breathing subjects. A cross-sectional study was conducted. The sample included 115 subject, 56 boys and 59 girls, 5-22-year-old. Among these, 80 were classified as oral breathers and 35 as physiological breathers. The diagnosis of oral breathing was carried out thanks to characteristic signs and symptoms evaluated on clinical examination, the analysis of characteristic X-ray images, ENT examination with active anterior rhinomanometric (AAR) test. The structural and postural analysis was carried out, calculating the craniofacial angles NSL/OPT and NSL/CVT. Both NSL/OPT and NSL/CVT appear to be significantly greater to those observed in physiological breathing patients. This means that patients who tend to breathe through the mouth rather than exclusively through the nose show a reduction of cervical lordosis and a proinclination of the head. Our study confirms that the oral breathing modifies head position. The significant increase of the craniocervical angles NSL/OPT and NSL/CVT in patients with this altered breathing pattern suggests an elevation of the head and a greater extension of the head compared with the cervical spine. So, to correct the breathing pattern early, either during childhood or during adolescence, can lead to a progressive normalization of craniofacial morphology and head posture.

  18. Small angle neutron scattering study of metallic alloys by a double crystal device

    International Nuclear Information System (INIS)

    Cser, L.; Kovacs, I.; Kroo, N.; Zsigmond, Gy.

    1982-06-01

    A double crystal small angle neutron scattering (SANS) device was built and a simple method for measuring the integrated SANS intensity was developed. The device and the method were tested and the possibility of future applications was demonstrated by measurements on different samples. The test measurements were performed on iron and teflon slabs of different thickness. On Fe-B metallic glasses a SANS intensity originating mainly from the multiple magnetic refraction at domain boundaries was observed. A very weak SANS intensity was found on turbine blades. The integrated SANS intensity was shown to correlate with the running time of the blades. Similar measurements were performed on artificially deformed steel samples. (author)

  19. [Inferring landmark displacements from changes in cephalometric angles].

    Science.gov (United States)

    Xu, T; Baumrind, S

    2001-07-01

    To investigate the appropriateness of using changes in angular measurements to reflect the actually profile changes. The sample consists of 48 growing malocclusion patients, contained 24 Class I and 24 Class II subjects, treated by an experienced orthodontist using Edgewise technique. Landmark and superimpositional data were extracted from the previously prepared numerical database. Three pairs of angular and linear measures were computed by the Craniofacial Software Package. Although the associations between all three angular measures and their corresponding linear measures are statistically significant at the 0.001 level, the disagreement between these three pairs of measures are 10.4%, 22.9% and 37.5% respectively in this sample. The direction of displacement of anterior facial landmarks during growth and treatment cannot reliably be inferred merely from changes in cephalometric Angles.

  20. Evaluation of Aneurysm Neck Angle Change After Endovascular Aneurysm Repair Clinical Investigations

    Energy Technology Data Exchange (ETDEWEB)

    Le, Trong Binh; Moon, Mi Hyoung [Inha University Hospital, Endovascular Training Center (Korea, Republic of); Jeon, Yong Sun, E-mail: radjeon@inha.ac.kr [Inha University Hospital, Inha University School of Medicine, Department of Radiology (Korea, Republic of); Hong, Kee Chun [Inha University School of Medicine, Department of Vascular Surgery (Korea, Republic of); Cho, Soon Gu [Inha University Hospital, Inha University School of Medicine, Department of Radiology (Korea, Republic of); Park, Keun-Myoung [Inha University School of Medicine, Department of Vascular Surgery (Korea, Republic of)

    2016-05-15

    PurposeTo evaluate the aneurysm neck angle changes and post-endovascular aneurysm repair (EVAR) complications.MethodsWe retrospectively analyzed 72 cases of elective EVAR for abdominal aortic aneurysm among 109 consecutive cases from December 2005 to April 2014. Patients were divided into angulated and non-angulated groups. The angulated group was defined as neck angulation ≥60°. Neck angle was evaluated pre- and post-EVAR during short- (within 1 month), mid- (3–6 months), and long-term (>1 year) follow-up. Aneurysm sac diameter change, aneurysm neck morphology other than angulation, endoleaks, and other post-procedural complications were also documented.ResultsA total of 34 patients were enrolled in the angulated group. There were no statistical differences in age, sex, follow-up duration, and aneurysm neck profile between the two groups (p > 0.05). Both groups showed statistically significant and consistent decreases in angulation during the follow-up period (p < 0.01). The angulated group revealed 22.45 % more straightening than the non-angulated group. Recoil of the Endurant device occurred in the angulated group. No statistically significant intergroup differences were observed in any endoleaks, complications, or re-intervention rates (p > 0.05). Pre-EVAR angle was the only predictor for post-procedural angle change (p < 0.001).ConclusionEVAR is applicable for patients with highly angulated aneurysm neck and provides consistent neck straightening over long-term follow-up. Recoil was evident in the angulated group using the Endurant device.

  1. Projected phase-change memory devices.

    Science.gov (United States)

    Koelmans, Wabe W; Sebastian, Abu; Jonnalagadda, Vara Prasad; Krebs, Daniel; Dellmann, Laurent; Eleftheriou, Evangelos

    2015-09-03

    Nanoscale memory devices, whose resistance depends on the history of the electric signals applied, could become critical building blocks in new computing paradigms, such as brain-inspired computing and memcomputing. However, there are key challenges to overcome, such as the high programming power required, noise and resistance drift. Here, to address these, we present the concept of a projected memory device, whose distinguishing feature is that the physical mechanism of resistance storage is decoupled from the information-retrieval process. We designed and fabricated projected memory devices based on the phase-change storage mechanism and convincingly demonstrate the concept through detailed experimentation, supported by extensive modelling and finite-element simulations. The projected memory devices exhibit remarkably low drift and excellent noise performance. We also demonstrate active control and customization of the programming characteristics of the device that reliably realize a multitude of resistance states.

  2. Angle parameter changes of phacoemulsification and combined phacotrabeculectomy for acute primary angle closure

    Directory of Open Access Journals (Sweden)

    Shi-Wei Li

    2015-08-01

    Full Text Available AIM: To evaluate the difference in angle parameters and clinical outcome following phacoemulsification and combined phacotrabeculectomy in patients with acute primary angle closure (APAC using ultrasound biomicroscopy (UBM.METHODS: Patients (n=23, 31 eyes were randomized to receive phacoemulsification or combined phacotrabeculectomy (n=24, 31 eyes. Best-corrected visual acuity (BCVA, intraocular pressure (IOP, the main complications following surgery, and indentation gonioscopy and angle parameters measured using UBM were documented preoperatively and postoperatively.RESULTS:The improvement in BCVA in the phacoemulsification group was significantly greater than in the combined group (P<0.05. IOP in the phacoemulsification group was slightly higher than in the combined group following 1wk of follow-up (P<0.05, whereas there was no significant difference between the two groups at the latter follow-up (P>0.05. Phacoemulsification alone resulted in a slight increase in the trabecular ciliary processes distance compared with the combined surgery (P<0.05, whereas the other angle parameters showed no significant difference between the groups. Complications in combined group were greater than phacoemulsification only group.CONCLUSION:Both surgeries effectively opened the drainage angle and deepened the anterior chamber, and IOP was well controlled postoperatively. However, phacoemulsification showed better efficacy in improving visual function and showed reduced complications following surgery.

  3. From the Weinberg Angle to Cardiac MRI a career change

    CERN Document Server

    ten Have, I.

    1997-01-01

    In summer 1994 I left particle physics to pursue a career in industry. Now three years later I am working for Philips Medical Systems in the Netherlands. I am responsible, both technically and commercially, for adapting the exist-ingMagnetic Resonance Imaging (MRI) technique for cardiology applications. In this seminar I will talk about the interesting challenges my current position holds for me. I will present the substantial added value of my working experience at CERN: the physics research, working at technological frontiers, the international collaboration, expatriate life. Finally I will also describe what I have done to actively support this career change. Speaker: 1985-1989 Ð University of Nijmegen and CERN - Ph.D. on B0-B0bar mixing, Eurojet, top quark cross-sections, test of the O(as3) QCD matrix element, calculations for future hadron colliders, UA1. 1989-1994 Ð University of Glasgow and CERN - ALEPH - Jet charge studies, measurement of the Weinberg Angle. 1994-1996 Ð Master of Business Administr...

  4. Non-binary Colour Modulation for Display Device Based on Phase Change Materials

    Science.gov (United States)

    Ji, Hong-Kai; Tong, Hao; Qian, Hang; Hui, Ya-Juan; Liu, Nian; Yan, Peng; Miao, Xiang-Shui

    2016-12-01

    A reflective-type display device based on phase change materials is attractive because of its ultrafast response time and high resolution compared with a conventional display device. This paper proposes and demonstrates a unique display device in which multicolour changing can be achieved on a single device by the selective crystallization of double layer phase change materials. The optical contrast is optimized by the availability of a variety of film thicknesses of two phase change layers. The device exhibits a low sensitivity to the angle of incidence, which is important for display and colour consistency. The non-binary colour rendering on a single device is demonstrated for the first time using optical excitation. The device shows the potential for ultrafast display applications.

  5. Non-binary Colour Modulation for Display Device Based on Phase Change Materials.

    Science.gov (United States)

    Ji, Hong-Kai; Tong, Hao; Qian, Hang; Hui, Ya-Juan; Liu, Nian; Yan, Peng; Miao, Xiang-Shui

    2016-12-19

    A reflective-type display device based on phase change materials is attractive because of its ultrafast response time and high resolution compared with a conventional display device. This paper proposes and demonstrates a unique display device in which multicolour changing can be achieved on a single device by the selective crystallization of double layer phase change materials. The optical contrast is optimized by the availability of a variety of film thicknesses of two phase change layers. The device exhibits a low sensitivity to the angle of incidence, which is important for display and colour consistency. The non-binary colour rendering on a single device is demonstrated for the first time using optical excitation. The device shows the potential for ultrafast display applications.

  6. Economic Models as Devices of Policy Change

    DEFF Research Database (Denmark)

    Henriksen, Lasse Folke

    2013-01-01

    Can the emergence of a new policy model be a catalyst for a paradigm shift in the overall interpretative framework of how economic policy is conducted within a society? This paper claims that models are understudied as devices used by actors to induce policy change. This paper explores the role...... of models in Danish economic policy, where, from the 1970s onwards, executive public servants in this area have exclusively been specialists in model design. To understand changes in economic policy, this paper starts with a discussion of whether the notion of paradigm shift is adequate. It then examines...... the extent to which the performativity approach can help identify macroscopic changes in policy from seemingly microscopic changes in policy models. The concept of performativity is explored as a means of thinking about the constitution of agency directed at policy change. The paper brings this concept...

  7. Clinical results with the Trabectome, a novel surgical device for treatment of open-angle glaucoma.

    Science.gov (United States)

    Minckler, Don; Baerveldt, George; Ramirez, Marina Alfaro; Mosaed, Sameh; Wilson, Richard; Shaarawy, Tarek; Zack, Barend; Dustin, Laurie; Francis, Brian

    2006-01-01

    To describe treatment outcomes after Trabectome surgery in an initial series of 101 patients with open-angle glaucoma. A 19-gauge microelectrosurgical device enabled ab interno removal of a strip of trabecular meshwork and inner wall of Schlemm's canal under gonioscopic control with continual infusion and foot-pedal control of aspiration and electrosurgery. A smooth, pointed ceramic-coated insulating footplate was inserted into Schlemm's canal to act as a guide within the canal and to protect adjacent structures from mechanical or heat injury during ablation of a 30- to 90-degree arc of angle tissue. Mean preoperative intraocular pressure (IOP) in the initial 101 patients was 27.6 +/- 7.2 mm Hg. Thirty months postoperatively, mean IOP was 16.3 +/- 3.3 mm Hg (n = 11). The mean percentage drop over the whole course of follow-up was 40%. At all times postoperatively, the absolute and percent decrease in IOP from preoperative levels were statistically significant (paired t test, P < .0001). Overall success (IOP

  8. Does the urethral angle change with leg position? Implications for urethral-based CT-planned transperineal prostate implants

    International Nuclear Information System (INIS)

    Bednarz, Greg; Ning, Yue; Waterman, Frank M.; Corn, Benjamin W.; Dicker, Adam P.

    1997-01-01

    Purpose: CT based treatment planning for transperineal prostate implants allows for angulation of transperineal needles to avoid the pubic bones by changing the template angle. It requires fluoroscopic guidance and utilizes identification of the urethra by radiopaque markers inside the Foley catheter at the time of the implant. The needle trajectory is relative to the urethral angle as visualized by lateral fluoroscopic views. Patients who have a treatment planning CT in preparation for a transperineal prostate implant are typically scanned in the leg-down/straight position. However, the implant is done in the lithotomy position and changes in the template angle to adapt to the new urethral angle are often required. We have evaluated the relationship between leg position and the position of the prostatic urethra to predict the change in the planned template angle. Material and Methods: To duplicate the lithotomy position a custom designed foot holder was constructed that attached to a flatbed CT scanner. A Foley catheter was inserted with radio-opaque contrast placed in the balloon. Bladder contrast was also utilized. A catheter with 1 cm spaced dummy seeds was placed inside the Foley catheter. A radio-opaque catheter was inserted into the rectum. Fifteen patients had pre-implant scans performed in the leg-down/straight and lithotomy position. The prostate, urethra, bladder and rectum were contoured utilizing a 3D-brachytherapy software system and analyzed. Results: Fourteen of the patients (93%) had changes in urethral angle when evaluated in the lithotomy relative to the led-down/straight position. The mean angle change was - 9.8 degrees (Std. Error 1.47 degrees; p < 0.0001) when in the lithotomy position. The changes were not correlated with prostatic volume or clinical stage. All patients who had urethral angle changes would have required adjustments in the template angle. Conclusions: 1) The objective of treatment planning for prostate implants is to

  9. Neuromuscular adaptations associated with knee joint angle-specific force change.

    Science.gov (United States)

    Noorkõiv, Marika; Nosaka, Kazunori; Blazevich, Anthony J

    2014-08-01

    Neuromuscular adaptations to joint angle-specific force increases after isometric training have not yet been fully elucidated. This study examined angle-specific neuromuscular adaptations in response to isometric knee extension training at short (SL, joint angle 38.1° ± 3.7°) versus long (LL, 87.5° ± 6.0°) muscle lengths. Sixteen men trained three times a week for 6 wk either at SL (n = 8) or LL (n = 8). Voluntary maximal isometric knee extensor (MVC) force, doublet twitch force, EMG amplitudes (EMG/Mmax), and voluntary activation during MVC force (VA%) were measured at eight knee joint angles (30°-100°) at weeks 0, 3, and 6. Muscle volume and cross-sectional area (CSA) were measured from magnetic resonance imaging scans, and fascicle length (Lf) was assessed using ultrasonography before and after training. Clear joint angle specificity of force increase was seen in SL but not in LL. The 13.4% ± 9.7% (P = 0.01) force increase around the training angle in SL was related to changes in vastus lateralis and vastus medialis EMG/Mmax around the training angle (r = 0.84-0.88, P < 0.05), without changes in the doublet twitch force-angle relation or muscle size. In LL, muscle volume and CSA increased and the changes in CSA at specific muscle regions were correlated with changes in MVC force. A 5.4% ± 4.9% (P = 0.001) increase in Lf found in both groups was not associated with angle-specific force changes. There were no angle-specific changes in VA%. The EMG/Mmax, although not VA%, results suggest that neural adaptations underpinned training-related changes at short quadriceps lengths, but hypertrophic changes predominated after training at long lengths. The findings of this study should contribute to the development of more effective and evidence-based rehabilitation and strength training protocols.

  10. Anterior segment changes after pharmacologic mydriasis using Pentacam and optical coherence tomography in angle closure suspects

    Directory of Open Access Journals (Sweden)

    Jing-Min Guo

    2015-10-01

    Full Text Available AIM:To compare the dynamic changes of anterior segment parameters especially iris morphology induced by pharmacologic mydriasis between angle closure suspects and normal controls.METHODS:The study group comprised 19 eyes of 19 angle closure suspects and 19 eyes of 19 age- and sex-matched normal open-angle eyes. Pentacam and optical coherence tomography measurements before and 30min after instillation of compound tropicamide eye drop were performed and compared. Biometric evaluations of iris tomography and anterior chamber angle were estimated by a customized image-processing software.RESULTS:Baseline axial length, iris cross sectional area and volume did not differ significantly between angle closure suspects and normal controls. Angle closure suspects had smaller pupil size, narrower anterior segment dimension and axial length, thinner iris with greater curve in comparison with normal controls. Pharmacologic mydriasis led to significant increments in iris thickness at 750 μm, anterior chamber depth and volume, whereas significant decrements in iris curve, cross sectional area and volume in both groups. Angle opening distance at 500 μm was increased significantly in normal controls (from 0.465±0.115 mm to 0.539±0.167 mm, P=0.009, but not in angle closure suspects (from 0.125±0.100 mm to 0.145±0.131 mm, P=0.326. Iris volume change per millimeter of pupil dilation (△IV/△PD decreased significantly less in angle closure suspects than normal controls (-2.47±1.33 mm2 vs -3.63±1.58 mm2, P=0.019. Linear regression analysis showed that the change of angle opening distance at 500 μm was associated most with the change of central anterior chamber depth (β=0.841, P=0.002 and △IV/△PD (β=0.028, P=0.002, followed by gender (β=0.062, P=0.032.CONCLUSION:Smaller iris volume decrement per millimeter of pupil dilation is related significantly with the less anterior angle opening in angle closure suspects after pharmacologic mydriasis. Dynamic

  11. The changes of the interspace angle after anterior correction and instrumentation in adolescent idiopathic scoliosis patients

    Directory of Open Access Journals (Sweden)

    Fei Qi

    2007-10-01

    Full Text Available Abstract Background In idiopathic scoliosis patients, after anterior spinal fusion and instrumentation, the discs (interspace angle between the lowest instrumented vertebra (LIV and the next caudal vertebra became more wedged. We reviewed these patients and analyzed the changes of the angle. Methods By reviewing the medical records and roentgenograms of adolescent idiopathic scoliosis patients underwent anterior spinal fusion and instrumentation, Cobb angle of the curve, correction rate, coronal balance, LIV rotation, interspace angle were measured and analyzed. Results There were total 30 patients included. The mean coronal Cobb angle of the main curve (thoracolumbar/lumbar curve before and after surgery were 48.9° and 11.7°, respectively, with an average correction rate of 76.1%. The average rotation of LIV before surgery was 2.1 degree, and was improved to 1.2 degree after surgery. The interspace angle before surgery, on convex side-bending films, after surgery, at final follow up were 3.2°, -2.3°, 1.8° and 4.9°, respectively. The difference between the interspace angle after surgery and that preoperatively was not significant (P = 0.261, while the interspace angle at final follow-up became larger than that after surgery, and the difference was significant(P = 0.012. The interspace angle after surgery was correlated with that on convex side-bending films (r = 0.418, P = 0.022, and the interspace angle at final follow-up was correlated with that after surgery (r = 0.625, P = 0.000. There was significant correlation between the loss of the interspace angle and the loss of coronal Cobb angle of the main curve during follow-up(r = 0.483, P = 0.007. Conclusion The interspace angle could be improved after anterior correction and instrumentation surgery, but it became larger during follow-up. The loss of the interspace angle was correlated with the loss of coronal Cobb angle of the main curve during follow-up.

  12. Devices and process for high-pressure magic angle spinning nuclear magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Hoyt, David W.; Sears, Jesse A.; Turcu, Romulus V. F.; Rosso, Kevin M.; Hu, Jian Zhi

    2017-12-05

    A high-pressure magic angle spinning (MAS) rotor is detailed that includes a high-pressure sample cell that maintains high pressures exceeding 150 bar. The sample cell design minimizes pressure losses due to penetration over an extended period of time.

  13. Devices and process for high-pressure magic angle spinning nuclear magnetic resonance

    Science.gov (United States)

    Hoyt, David W; Sears, Jr., Jesse A; Turcu, Romulus V.F.; Rosso, Kevin M; Hu, Jian Zhi

    2014-04-08

    A high-pressure magic angle spinning (MAS) rotor is detailed that includes a high-pressure sample cell that maintains high pressures exceeding 150 bar. The sample cell design minimizes pressure losses due to penetration over an extended period of time.

  14. Do changes in neuromuscular activation contribute to the knee extensor angle-torque relationship?

    Science.gov (United States)

    Lanza, Marcel B; Balshaw, Thomas G; Folland, Jonathan P

    2017-08-01

    What is the central question of the study? Do changes in neuromuscular activation contribute to the knee extensor angle-torque relationship? What is the main finding and its importance? Both agonist (quadriceps) and antagonist coactivation (hamstrings) differed with knee joint angle during maximal isometric knee extensions and thus both are likely to contribute to the angle-torque relationship. Specifically, two independent measurement techniques showed quadriceps activation to be lower at more extended positions. These effects might influence the capacity for neural changes in response to training and rehabilitation at different knee joint angles. The influence of joint angle on knee extensor neuromuscular activation is unclear, owing in part to the diversity of surface electromyography (sEMG) and/or interpolated twitch technique (ITT) methods used. The aim of the study was to compare neuromuscular activation, using rigorous contemporary sEMG and ITT procedures, during isometric maximal voluntary contractions (iMVCs) of the quadriceps femoris at different knee joint angles and examine whether activation contributes to the angle-torque relationship. Sixteen healthy active men completed two familiarization sessions and two experimental sessions of isometric knee extension and knee flexion contractions. The experimental sessions included the following at each of four joint angles (25, 50, 80 and 106 deg): iMVCs (with and without superimposed evoked doublets); submaximal contractions with superimposed doublets; and evoked twitch and doublet contractions whilst voluntarily passive, and knee flexion iMVC at the same knee joint positions. The absolute quadriceps femoris EMG was normalized to the peak-to-peak amplitude of an evoked maximal M-wave, and the doublet-voluntary torque relationship was used to calculate activation with the ITT. Agonist activation, assessed with both normalized EMG and the ITT, was reduced at the more extended compared with the more flexed

  15. Evaluation of stress gradient by x-ray stress measurement based on change in angle phi

    International Nuclear Information System (INIS)

    Sasaki, Toshihiko; Kuramoto, Makoto; Yoshioka, Yasuo.

    1985-01-01

    A new principle of X-ray stress evaluation for a sample with steep stress gradient has been prosed. The feature of this method is that the stress is determined by using so-called phi-method based on the change of phi-angle and thus has no effect on the penetration depth of X-rays. The procedure is as follows; firstly, an average stress within the penetration depth of X-rays is determined by changing only phi-angle under a fixed psi-angle, and then a distribution of the average stress vs. the penetration depth of X-rays is detected by repeating the similar procedure at different psi-angles. The following conclusions were found out as the result of residual stress measurements on a carbon steel of type S 55 C polished by emery paper. This method is practical enough to use for a plane stress problem. And the assumption of a linear stress gradient adopted in the authors' previous investigations is valid. In case of a triaxial stress analysis, this method is effective for the solution of three shearing stresses. However, three normal stresses can not be solved perfectly except particular psi-angles. (author)

  16. Position Angle Changes of Inner-Jets in a Sample of Blazars Ligong ...

    Indian Academy of Sciences (India)

    Position Angle Changes of Inner-Jets in a Sample of Blazars. Ligong Mi1,3,∗ & Xiang Liu1,2. 1Xinjiang Astronomical Observatory, CAS, 150 Science 1-Street, Urumqi 830011,. People's Republic of China. 2Key Laboratory of Radio Astronomy, CAS, Nanjing 210008, People's Republic of China. 3University of Chinese ...

  17. Color change mechanism of niobium oxide thin film with incidental light angle and applied voltage

    Energy Technology Data Exchange (ETDEWEB)

    Komatsu, Isao [Course of Information Science and Technology, Graduate School of Science and Technology, Tokai University (Japan); Aoki, Hayata [Course of Electro Photo Optics, Graduate School of Engineering, Tokai University (Japan); Ebisawa, Mizue [Tokyo Metropolitan Industrial Technology Research Institute (Japan); Kuroda, Akihiro [Department of Optical and Imaging Science & Technology, Faculty of Engineering, Tokai University (Japan); Kuroda Consulting Incorporated (Japan); Kuroda, Koichi [Kuroda Consulting Incorporated (Japan); Maeda, Shuichi [Course of Information Science and Technology, Graduate School of Science and Technology, Tokai University (Japan); Course of Electro Photo Optics, Graduate School of Engineering, Tokai University (Japan); Department of Optical and Imaging Science & Technology, Faculty of Engineering, Tokai University (Japan)

    2016-03-31

    Niobium oxide thin layers made by the anodization process showed coloration owing to thin film interference. The reflection spectra depended on both the applied voltage and incident light angle. Large color differences were observed at incident light angles between 5° and 70°, when the applied voltage was over 60 V. In this study, we explored the cause of these results using ellipsometry and goniophotometry to understand the transition of optical constants and the reflection spectra with applied voltage. Finally, we concluded that the coloration of the reflection spectra, which included only a first-order interference peak, exhibits a smaller change because the first order interference peak has a wider half value width than higher order interference peaks. - Highlights: • We investigated color change of Nb{sub 2}O{sub 5} oxide thin layers with incidental light angle. • The reflection spectra shift to lower wavelength region with increasing incident light angle. • The reflection spectra shift to higher wavelength region with increasing applied voltage. • First-order interference has wider half value width, and exhibits small color change.

  18. Forced Ion Migration for Chalcogenide Phase Change Memory Device

    Science.gov (United States)

    Campbell, Kristy A (Inventor)

    2013-01-01

    Non-volatile memory devices with two stacked layers of chalcogenide materials comprising the active memory device have been investigated for their potential as phase-change memories. The devices tested included GeTe/SnTe, Ge2Se3/SnTe, and Ge2Se3/SnSe stacks. All devices exhibited resistance switching behavior. The polarity of the applied voltage with respect to the SnTe or SnSe layer was critical to the memory switching properties, due to the electric field induced movement of either Sn or Te into the Ge-chalcogenide layer. One embodiment of the invention is a device comprising a stack of chalcogenide-containing layers which exhibit phase-change switching only after a reverse polarity voltage potential is applied across the stack causing ion movement into an adjacent layer and thus "activating" the device to act as a phase-change random access memory device or a reconfigurable electronics device when the applied voltage potential is returned to the normal polarity. Another embodiment of the invention is a device that is capable of exhibiting more than two data states.

  19. A mathematical model for predicting lane changes using the steering wheel angle.

    Science.gov (United States)

    Schmidt, Kim; Beggiato, Matthias; Hoffmann, Karl Heinz; Krems, Josef F

    2014-06-01

    Positive safety effects of advanced driver assistance systems can only become effective if drivers accept and use these systems. Early detection of driver's intention would allow for selective system activation and therefore reduce false alarms. This driving simulator study aims at exploring early predictors of lane changes. In total, 3111 lane changes of 51 participants on a simulated highway track were analyzed. Results show that drivers stopped their engagement in a secondary task about 7s before crossing the lane, which indicates a first planning phase of the maneuver. Subsequently, drivers start moving toward the lane, marking a mean steering wheel angle of 2.5°. Steering wheel angle as a directly measurable vehicle parameter appears as a promising early predictor of a lane change. A mathematical model of the steering wheel angle is presented, which is supposed to contribute for predicting lane change maneuvers. The mathematical model will be part of a further predictor of lane changes. This predictor can be a new advanced driver assistance system able to recognize a driver's intention. With this knowledge, other systems can be activated or deactivated so drivers get no annoying and exhausting alarm signals. This is one way how we can increase the acceptance of assistance systems. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Detection of small conformational changes of proteins by small-angle scattering

    International Nuclear Information System (INIS)

    Durchschlag, H.; Purr, G.; Zipper, P.; Wilfing, R.

    1991-01-01

    In the past the technique of small-angle scattering has been a powerful tool for studying conformational changes of protein which occur, for example, upon binding with ligands. Results obtained by different authors from X-ray and neutron experiments on a variety of proteins and under various conditions have been compiled. This offers the possibility of comparing the extent of changes in the molecular parameters investigated (e.g. change of the radius of gyration). Problems encountered with the detection of small changes are discussed. As an example, conformational changes of the enzyme citrate synthase upon substrate binding (oxaloacetate) are presented. X-ray crystallography had already found distinct changes between open and closed forms of the enzyme. Small-angle X-ray scattering studies registered slight changes of some parameters in solution. These changes could be paralleled with the results of other solution techniques (UV absorption, fluorescence and circular dichroism spectroscopy, analytical ultracentrifugation). The results found for citrate synthase are also compared with previous findings for malate synthase, an enzyme of similar enzymatic function. Above all, this study shows that care has to be taken when studying small conformational changes. It is absolutely necessary to use different methods and conditions and to study the problem from different points of view to avoid pitfalls. (orig.)

  1. Real-time change detection for countering improvised explosive devices

    NARCIS (Netherlands)

    Wouw, van de D.W.J.M.; Rens, van K.; Lint, van R.H.; Jaspers, Egbert; With, de P.H.N.; Loce, R.P.; Saber, E.

    2014-01-01

    We explore an automatic real-time change detection system to assist military personnel during transport and surveillance, by detection changes in the environment with respect to a previous operation. Such changes may indicate the presence of Improvised Explosive Devices (IEDs), which can then be

  2. Changes in Anterior Segment Morphology and Predictors of Angle Widening after Laser Iridotomy in South Indian Eyes.

    Science.gov (United States)

    Zebardast, Nazlee; Kavitha, Srinivasan; Krishnamurthy, Palaniswamy; Friedman, David S; Nongpiur, Monisha E; Aung, Tin; Quigley, Harry A; Ramulu, Pradeep Y; Venkatesh, Rengaraj

    2016-12-01

    To compare anterior segment optical coherence tomography (ASOCT) angle morphology before and after laser peripheral iridotomy (LPI) in a cohort of South Indian subjects with primary angle-closure suspect (PACS) or primary angle-closure/primary angle-closure glaucoma (PAC/PACG) and to examine baseline parameters associated with angle widening. Prospective observational study. A total of 244 subjects aged ≥30 years with PACS or PAC/PACG in at least 1 eye. The ASOCT images and angle gonioscopic grades were analyzed for all subjects at baseline and 2 weeks after LPI. Multivariable linear and logistic regression models were used to determine predictors of angle widening (change in mean angle opening distance [AOD750]) and angle opening (all 4 quadrants with trabecular meshwork [TM] visible on gonioscopy after LPI). Change in ASOCT parameters with LPI and baseline predictors of angle widening. Laser peripheral iridotomy resulted in angle widening on ASOCT with significant increases in AOD750, angle recess area, and trabecular iris surface area (P gonioscopy, although some degree of persistent iridotrabecular contact was present in approximately half of PACS eyes and approximately two thirds of PAC/PACG eyes on gonioscopy. The greatest widening by ASOCT was observed in eyes with features most consistent with greater baseline pupillary block. Copyright © 2016 American Academy of Ophthalmology. All rights reserved.

  3. On the use of ultracentrifugal devices for routine sample preparation in biomolecular magic-angle-spinning NMR.

    Science.gov (United States)

    Mandal, Abhishek; Boatz, Jennifer C; Wheeler, Travis B; van der Wel, Patrick C A

    2017-03-01

    A number of recent advances in the field of magic-angle-spinning (MAS) solid-state NMR have enabled its application to a range of biological systems of ever increasing complexity. To retain biological relevance, these samples are increasingly studied in a hydrated state. At the same time, experimental feasibility requires the sample preparation process to attain a high sample concentration within the final MAS rotor. We discuss these considerations, and how they have led to a number of different approaches to MAS NMR sample preparation. We describe our experience of how custom-made (or commercially available) ultracentrifugal devices can facilitate a simple, fast and reliable sample preparation process. A number of groups have since adopted such tools, in some cases to prepare samples for sedimentation-style MAS NMR experiments. Here we argue for a more widespread adoption of their use for routine MAS NMR sample preparation.

  4. On the use of ultracentrifugal devices for routine sample preparation in biomolecular magic-angle-spinning NMR

    Energy Technology Data Exchange (ETDEWEB)

    Mandal, Abhishek; Boatz, Jennifer C. [University of Pittsburgh School of Medicine, Department of Structural Biology (United States); Wheeler, Travis B. [University of Pittsburgh School of Medicine, Department of Cell Biology (United States); Wel, Patrick C. A. van der, E-mail: vanderwel@pitt.edu [University of Pittsburgh School of Medicine, Department of Structural Biology (United States)

    2017-03-15

    A number of recent advances in the field of magic-angle-spinning (MAS) solid-state NMR have enabled its application to a range of biological systems of ever increasing complexity. To retain biological relevance, these samples are increasingly studied in a hydrated state. At the same time, experimental feasibility requires the sample preparation process to attain a high sample concentration within the final MAS rotor. We discuss these considerations, and how they have led to a number of different approaches to MAS NMR sample preparation. We describe our experience of how custom-made (or commercially available) ultracentrifugal devices can facilitate a simple, fast and reliable sample preparation process. A number of groups have since adopted such tools, in some cases to prepare samples for sedimentation-style MAS NMR experiments. Here we argue for a more widespread adoption of their use for routine MAS NMR sample preparation.

  5. Functional and Structural Changes in a Canine Model of Hereditary Primary Angle-Closure Glaucoma

    Science.gov (United States)

    Kecova, Helga; Harper, Matthew M.; Nilaweera, Wijitha; Kuehn, Markus H.; Kardon, Randy H.

    2010-01-01

    Purpose. To characterize functional and structural changes in a canine model of hereditary primary angle-closure glaucoma. Methods. Intraocular pressure (IOP) was evaluated with tonometry in a colony of glaucomatous dogs at 8, 15, 18, 20, and 30 months of age. Retinal function was evaluated using electroretinography (scotopic, photopic, and pattern). Examination of anterior segment structures was performed using gonioscopy and high-frequency ultrasonography (HFU). Results. A gradual rise in IOP was observed with an increase in age: 8 months, 14 mm Hg (median value); 15 months, 15.5 mm Hg; 18 months, 17.5 mm Hg; 20 months, 24 mm Hg; 30 months, 36 mm Hg. Provocative testing with mydriatic agents (tropicamide and atropine 1%) caused significant increases in IOP (35% and 50%, respectively). HFU analysis showed complete collapse of iridocorneal angles by 20 months of age. Scotopic and photopic ERG analysis did not reveal significant deficits, but pattern ERG analysis showed significantly reduced amplitudes in glaucomatous dogs (glaucoma, 3.5 ± 0.4 μV; control, 6.2 ± 0.3 μV; P = 0.004; Student's t-test). Histologic analysis revealed collapse of the iridocorneal angle, posterior bowing of the lamina cribrosa, swelling and loss of large retinal ganglion cells, increased glial reactivity, and increased thickening of the lamina cribrosa. Conclusions. Canine hereditary angle-closure glaucoma is characterized by a progressive increase in intraocular pressure, loss of optic nerve function, and retinal ganglion cell loss. PMID:19661222

  6. A Designer Fluid For Aluminum Phase Change Devices. Performance Enhancement in Copper Heat Pipes Performance Enhancement in Copper Heat Pipes. Volume 3

    Science.gov (United States)

    2016-11-17

    comprised of a hollow metal shell filled with a small amount of working fluid creating a device that is extremely lightweight. Phase change devices...critical angle, the droplet unpins and the diameter decreases with a constant contact angle as the liquid core shrinks toward the center. Deegan et al...measurement system The thermocouple switch was encased in a box with fiberglass insulation to create an isothermal environment for the switch leads

  7. Changes in contact angle providing evidence for surface alteration in multi-component solid foods

    International Nuclear Information System (INIS)

    Reinke, Svenja K; Hauf, Katharina; Heinrich, Stefan; Vieira, Josélio; Palzer, Stefan

    2015-01-01

    Chocolate blooming, one of the major problems in the confectionery industry, is the formation of visible white spots or a greyish haze on the surface of chocolate products due to large sugar or fat crystals on the surface. This leads to aesthetic changes and deterioration of taste and thus large sales losses for the confectionery industry due to consumer complaints. Chocolate blooming is often related to migration of lipids or sugar molecules to the chocolate surface, where they recrystallize with an associated polymorphic change of crystal structure on the surface. The wetting behaviour from contact angle measurements gives further insight into surface properties and is needed to determine surface energies and to evaluate possible migration mechanisms and preferred pathways. Therefore, an equilibrium contact angle is needed which is not directly accessible and is influenced by surface texture and interaction between solid and test liquid. In this study, the surface of cocoa butter and conventional chocolates was characterized by measuring the contact angle with the sessile drop protocol. The influence of roughness, test liquid and pre-crystallization of the samples as well as the storage temperature were investigated. In case of no pre-crystallization, a change in surface properties due to storage at 20 °C was detected, whereas samples stored at 30 °C showed the same wetting behaviour as fresh samples. This is associated with polymorphic transformation from thermodynamically less stable crystals to more stable configurations. (paper)

  8. Changes in contact angle providing evidence for surface alteration in multi-component solid foods

    Science.gov (United States)

    Reinke, Svenja K.; Hauf, Katharina; Vieira, Josélio; Heinrich, Stefan; Palzer, Stefan

    2015-11-01

    Chocolate blooming, one of the major problems in the confectionery industry, is the formation of visible white spots or a greyish haze on the surface of chocolate products due to large sugar or fat crystals on the surface. This leads to aesthetic changes and deterioration of taste and thus large sales losses for the confectionery industry due to consumer complaints. Chocolate blooming is often related to migration of lipids or sugar molecules to the chocolate surface, where they recrystallize with an associated polymorphic change of crystal structure on the surface. The wetting behaviour from contact angle measurements gives further insight into surface properties and is needed to determine surface energies and to evaluate possible migration mechanisms and preferred pathways. Therefore, an equilibrium contact angle is needed which is not directly accessible and is influenced by surface texture and interaction between solid and test liquid. In this study, the surface of cocoa butter and conventional chocolates was characterized by measuring the contact angle with the sessile drop protocol. The influence of roughness, test liquid and pre-crystallization of the samples as well as the storage temperature were investigated. In case of no pre-crystallization, a change in surface properties due to storage at 20 °C was detected, whereas samples stored at 30 °C showed the same wetting behaviour as fresh samples. This is associated with polymorphic transformation from thermodynamically less stable crystals to more stable configurations.

  9. Changes in Rectal Dose Due to Alterations in Beam Angles for Setup Uncertainty and Range Uncertainty in Carbon-Ion Radiotherapy for Prostate Cancer.

    Directory of Open Access Journals (Sweden)

    Yoshiki Kubota

    Full Text Available Carbon-ion radiotherapy of prostate cancer is challenging in patients with metal implants in one or both hips. Problems can be circumvented by using fields at oblique angles. To evaluate the influence of setup and range uncertainties accompanying oblique field angles, we calculated rectal dose changes with oblique orthogonal field angles, using a device with fixed fields at 0° and 90° and a rotating patient couch.Dose distributions were calculated at the standard angles of 0° and 90°, and then at 30° and 60°. Setup uncertainty was simulated with changes from -2 mm to +2 mm for fields in the anterior-posterior, left-right, and cranial-caudal directions, and dose changes from range uncertainty were calculated with a 1 mm water-equivalent path length added to the target isocenter in each angle. The dose distributions regarding the passive irradiation method were calculated using the K2 dose algorithm.The rectal volumes with 0°, 30°, 60°, and 90° field angles at 95% of the prescription dose were 3.4±0.9 cm3, 2.8±1.1 cm3, 2.2±0.8 cm3, and 3.8±1.1 cm3, respectively. As compared with 90° fields, 30° and 60° fields had significant advantages regarding setup uncertainty and significant disadvantages regarding range uncertainty, but were not significantly different from the 90° field setup and range uncertainties.The setup and range uncertainties calculated at 30° and 60° field angles were not associated with a significant change in rectal dose relative to those at 90°.

  10. Wearable Device-Based Gait Recognition Using Angle Embedded Gait Dynamic Images and a Convolutional Neural Network.

    Science.gov (United States)

    Zhao, Yongjia; Zhou, Suiping

    2017-02-28

    The widespread installation of inertial sensors in smartphones and other wearable devices provides a valuable opportunity to identify people by analyzing their gait patterns, for either cooperative or non-cooperative circumstances. However, it is still a challenging task to reliably extract discriminative features for gait recognition with noisy and complex data sequences collected from casually worn wearable devices like smartphones. To cope with this problem, we propose a novel image-based gait recognition approach using the Convolutional Neural Network (CNN) without the need to manually extract discriminative features. The CNN's input image, which is encoded straightforwardly from the inertial sensor data sequences, is called Angle Embedded Gait Dynamic Image (AE-GDI). AE-GDI is a new two-dimensional representation of gait dynamics, which is invariant to rotation and translation. The performance of the proposed approach in gait authentication and gait labeling is evaluated using two datasets: (1) the McGill University dataset, which is collected under realistic conditions; and (2) the Osaka University dataset with the largest number of subjects. Experimental results show that the proposed approach achieves competitive recognition accuracy over existing approaches and provides an effective parametric solution for identification among a large number of subjects by gait patterns.

  11. Wearable Device-Based Gait Recognition Using Angle Embedded Gait Dynamic Images and a Convolutional Neural Network

    Science.gov (United States)

    Zhao, Yongjia; Zhou, Suiping

    2017-01-01

    The widespread installation of inertial sensors in smartphones and other wearable devices provides a valuable opportunity to identify people by analyzing their gait patterns, for either cooperative or non-cooperative circumstances. However, it is still a challenging task to reliably extract discriminative features for gait recognition with noisy and complex data sequences collected from casually worn wearable devices like smartphones. To cope with this problem, we propose a novel image-based gait recognition approach using the Convolutional Neural Network (CNN) without the need to manually extract discriminative features. The CNN’s input image, which is encoded straightforwardly from the inertial sensor data sequences, is called Angle Embedded Gait Dynamic Image (AE-GDI). AE-GDI is a new two-dimensional representation of gait dynamics, which is invariant to rotation and translation. The performance of the proposed approach in gait authentication and gait labeling is evaluated using two datasets: (1) the McGill University dataset, which is collected under realistic conditions; and (2) the Osaka University dataset with the largest number of subjects. Experimental results show that the proposed approach achieves competitive recognition accuracy over existing approaches and provides an effective parametric solution for identification among a large number of subjects by gait patterns. PMID:28264503

  12. Association Between Changes in the Angle of Mandible and Reduced Bone Mineral Density

    International Nuclear Information System (INIS)

    Rehman, D.; Sarwath, S.; Nigar, N.

    2015-01-01

    Objective: To establish an association between the angle of mandible on an orthopantomogram (OPG) with reduced bone mineral density of femoral neck and spine on Dual Energy X-ray Absorptiometry (DXA) scan. Study Design: Cross-sectional study. Place and Duration of Study: Institute of Basic Medical Sciences (IBMS), Dow University of Health Sciences (DUHS), Karachi, from December 2011 to July 2012. Methodology: Female subjects between 25 and 85 years of age were divided into premenopausal (Group-I) and postmenopausal (Group II) groups. Dual Energy X-ray Absorptiometry (DXA) scan was done to divide Group-I and Group-II into normal (pre A, post A), osteopenic (pre B, post B) and osteoporotic (pre C, post C) groups. Changes seen in angle of mandible on orthopantomogram (OPG) in subgroups of Group-I were compared with each other and with subgroups of Group-II. SPSS version 16 was used to carry out the statistical analysis. Intragroup significance was evaluated through One Way Analysis Of Variance (ANOVA). For intergroup significance independent samples t-test was applied. Results: The angle of mandible (A) was significantly decreased in Intragroup comparison of Group-II (0.035) between Post normal (Post A) vs. Post osteopenic (Post B) groups. Intergroup comparison between Group-I and Group-II (0.005) showed a significant decrease in angle of mandible between Pre osteopenic (Pre B) vs. Post osteopenic (Post B). Conclusion: As decrease in angle of mandible was observed at stage of osteopenia, it can be conveniently used for early detection of osteoporosis. (author)

  13. Effect of Visual Angle on the Head Movement Caused by Changing Binocular Disparity

    Directory of Open Access Journals (Sweden)

    Toru Maekawa

    2011-10-01

    Full Text Available It has been shown that vertical binocular disparity has no or little effect on the perception of visual direction (Banks et al., 2002. On the other hand, our previous study has reported that a continuous change of vertical disparity causes an involuntary sway of the head (Maekawa et al., 2009. We predict that the difference between those results attributes to the dissociation between the processes for perception and action in the brain. The aim of this study is to investigate in more details the condition that influences the process of disparity information. The present experiment particularly varied the visual angle of stimulus presentation and measured the head movement and body sway caused by changing vertical disparity. Results showed that the head movement was greater as the visual angle of the stimulus was smaller. It has been reported that stimulus of only small visual angle affect depth perception (Erklens et al., 1995. Thus, our result suggests that perception and action produced by vertical disparity are consistent as far as the effect of the stimulus size is concerned.

  14. Muscle and reflex changes with varying joint angle in hemiparetic stroke

    Directory of Open Access Journals (Sweden)

    Alibiglou Laila

    2008-02-01

    Full Text Available Abstract Background Despite intensive investigation, the origins of the neuromuscular abnormalities associated with spasticity are not well understood. In particular, the mechanical properties induced by stretch reflex activity have been especially difficult to study because of a lack of accurate tools separating reflex torque from torque generated by musculo-tendinous structures. The present study addresses this deficit by characterizing the contribution of neural and muscular components to the abnormally high stiffness of the spastic joint. Methods Using system identification techniques, we characterized the neuromuscular abnormalities associated with spasticity of ankle muscles in chronic hemiparetic stroke survivors. In particular, we systematically tracked changes in muscle mechanical properties and in stretch reflex activity during changes in ankle joint angle. Modulation of mechanical properties was assessed by applying perturbations at different initial angles, over the entire range of motion (ROM. Experiments were performed on both paretic and non-paretic sides of stroke survivors, and in healthy controls. Results Both reflex and intrinsic muscle stiffnesses were significantly greater in the spastic/paretic ankle than on the non-paretic side, and these changes were strongly position dependent. The major reflex contributions were observed over the central portion of the angular range, while the intrinsic contributions were most pronounced with the ankle in the dorsiflexed position. Conclusion In spastic ankle muscles, the abnormalities in intrinsic and reflex components of joint torque varied systematically with changing position over the full angular range of motion, indicating that clinical perceptions of increased tone may have quite different origins depending upon the angle where the tests are initiated. Furthermore, reflex stiffness was considerably larger in the non-paretic limb of stroke patients than in healthy control subjects

  15. Development of Portable Digital Radiography System with a Device for Monitoring X-ray Source-Detector Angle and Its Application in Chest Imaging

    Directory of Open Access Journals (Sweden)

    Tae-Hoon Kim

    2017-03-01

    Full Text Available This study developed a device measuring the X-ray source-detector angle (SDA and evaluated the imaging performance for diagnosing chest images. The SDA device consisted of Arduino, an accelerometer and gyro sensor, and a Bluetooth module. The SDA values were compared with the values of a digital angle meter. The performance of the portable digital radiography (PDR was evaluated using the signal-to-noise (SNR, contrast-to-noise ratio (CNR, spatial resolution, distortion and entrance surface dose (ESD. According to different angle degrees, five anatomical landmarks were assessed using a five-point scale. The mean SNR and CNR were 182.47 and 141.43. The spatial resolution and ESD were 3.17 lp/mm (157 μm and 0.266 mGy. The angle values of the SDA device were not significantly difference as compared to those of the digital angle meter. In chest imaging, the SNR and CNR values were not significantly different according to the different angle degrees. The visibility scores of the border of the heart, the fifth rib and the scapula showed significant differences according to different angles (p < 0.05, whereas the scores of the clavicle and first rib were not significant. It is noticeable that the increase in the SDA degree was consistent with the increases of the distortion and visibility score. The proposed PDR with a SDA device would be useful for application in the clinical radiography setting according to the standard radiography guidelines.

  16. Changes of postoperative macular structure in primary angle closure disease complicated with cataract

    Directory of Open Access Journals (Sweden)

    Wen-long Liu

    2018-02-01

    Full Text Available AIM: To explore the change of postoperative macular structure in primary angle closure disease(PACDcomplicated with cataract. METHODS: The clinical data of 200 cases of PACD patients complicated with cataract treated in our hospital were analyzed retrospectively. The patients were divided into the Group A(n=60, 60 eyes, treated with trabeculectomy, the Group B(n=72, 72 eyes, given the phacoemulsification combined with intraocular lens implantationand the Group C(n=68, 68 eyes, given the trabeculectomy and phacoemulsification combined with intraocular lens implantation. The vision changes before and after treatment and the changes of intraocular pressure and macular thickness(foveal area, near central area, foveal surrounding areabefore operation and at 1wk, 1 and 3mo after operation were compared and observed, and the incidence of complications was compared between the two groups. RESULTS: There were significant differences in the improvement rate and reduction rate of visual acuity among three groups at 3mo after operation(PPPPPPPPPCONCLUSION: Phacoemulsification combined with intraocular lens implantation can relieve angle closure caused by pupillary block and lens factors, and can significantly improve the vision and reduce intraocular pressure of PACD patients with cataract, and it has small effects on postoperative macular edema with few complications.

  17. Changes in ocular biometry and anterior chamber parameters after pharmacologic mydriasis and peripheral iridotomy in primary angle closure suspects

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Razeghinejad

    2016-07-01

    Conclusions: This study showed no change in the ocular biometric and anterior chamber parameters including iridocorneal angle after PI and/or pharmacologic mydriasis except for increments in anterior chamber volume. This factor has the potential to be used as a numerical proxy for iris position in evaluating and monitoring patients with primary angle closure suspects after PI.

  18. Five-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucoma

    NARCIS (Netherlands)

    de Jong, Leo; Lafuma, Antoine; Aguadé, Anne-Sophie; Berdeaux, Gilles

    2011-01-01

    This study compared the efficacy of the EX-PRESS(®) glaucoma filtration device and trabeculectomy in primary open-angle glaucoma up to five years after surgery. Patients from a previously reported randomized, open-label, parallel-arm clinical trial in which 78 patients received either the EX-PRESS

  19. The impact of changing solar screen rotation angle and its opening aspect ratios on Daylight Availability in residential desert buildings

    KAUST Repository

    Sherif, Ahmed H.; Sabry, Hanan M.; Gadelhak, Mahmoud I.

    2012-01-01

    usually used to diffuse and prevent direct solar penetration into spaces. This paper investigates the impact of changing solar screen axial rotation angle and screen opening aspect ratio on daylighting performance in a typical residential living room space

  20. Angle change of the parent arteries after stent-assisted coil embolization of wide-necked intracranial bifurcation aneurysms

    International Nuclear Information System (INIS)

    Cho, W.-S.; Kang, H.-S.; Kim, J.E.; Kwon, O.-K.; Oh, C.W.; Cho, Y.D.; Han, M.H.

    2014-01-01

    Aim: To investigate the angle changes of the parent arteries after stent-assisted coil embolization of wide-necked intracranial bifurcation aneurysms. Materials and methods: The adjacent parent arterial angles before and after stent-assisted coil embolization were measured in 38 patients with aneurysms of the anterior communicating artery (ACoAA) and 41 patients with bifurcation aneurysms of the middle cerebral artery (MCABA). Variables were analysed in relation to the angle changes. Results: Vascular angles of the parent arteries significantly increased by 27.8° (±18.5°) immediately after stent-assisted coil embolization in 79 cases (p < 0.001), with 25.7° (±14.8°) in ACoAA and 29.7° (±21.4°) in MCABA, respectively. In 51 (64.6%) cases with follow-up angiography (mean interval 13.5 ± 4.1 months), vascular angles increased by 27.2° (±17.1°) immediately after treatment and further increased by 20.7° (±14.3°) at the last follow-up (all p < 0.001). More acute pre-stent angles of the parent arteries correlated with greater post-stent angle changes (p = 0.006). Younger age tended to be inversely related to post-stent angle changes (p = 0.091). Conclusion: Stent placement during coil embolization induced significant changes in the aneurysm–parent artery relationship. Further study is needed to elicit the association between angle change of the parent arteries and aneurysmal stability after coil embolization

  1. Comparative analysis of colour change measurement devices in textile industry

    Directory of Open Access Journals (Sweden)

    Paulina Gilewicz

    2014-08-01

    Full Text Available In the paper there is presented a trial of application of new measurement principle of colour change with the use of DigiEye device. Comparison of DigiEye with commonly use in the textile industry spectrophotometer Macbeth 2020 was an aim of determination of relationship between parameters of both measurement systems. Samples for the colour change assessment on both measurement systems were first aged in the Xenotest 150. Ageing process was done according to the method of blues scale. Results were obtained by the colour measurement devices before and after the ageing test each releasing the diaphragms during exposing the examined samples on the light. Result of colour change were obtained in the colour system CIE L*a*b*. The measurements were done for PES fabrics destined on the outer layers of clothing. [b]Keywords[/b]: textiles, spectrophotometer, colorimeter [b][/b

  2. Changes of creatine kinase structure upon ligand binding as seen by small-angle scattering

    Science.gov (United States)

    Forstner, Michael; Kriechbaum, Manfred; Laggner, Peter; Wallimann, Theo

    1996-09-01

    Small-angle X-ray and neutron scattering have been used to investigate structural changes upon binding of individual substrates or a transition state analogue complex (TSAC), consisting of Mg-ADP, creatine and KNO 3 to creatine kinase isoenzymes (dimeric M-CK and octameric Mi-CK) and monomeric arginine kinase (AK). Considerable changes in the shape and the size of the molecules occurred upon binding of Mg-ATP and TSAC, whereas creatine alone had only a small effect. In Mi-CK, the radius of gyration was reduced from 55.6 Å (free enzyme) to 48.9 Å (enzyme + Mg-ATP) and to 48.2 Å (enzyme + TSAC). The experiments performed with M-CK showed similar changes from 28.0 Å (free enzyme) to 25.6 Å (enzyme + Mg-ATP) and to 25.5 Å (enzyme + TSAC). Creatine alone did not lead to significant changes in the radii of gyration, nor did free ATP or ADP. AK showed the same behaviour: a change of the radius of gyration from 21.5 Å (free enzyme) to 19.7 Å (enzyme + MG-ATP), whereas with arginine alone only a minor change could be observed. The primary change in structure as seen with monomeric AK seems to be a magnesium-nucleotide induced domain movement relative to each other, whereas the effect of substrate may be of local order only. In creatine kinase, however, further movements must be involved in the large conformational change.

  3. The change in color matches with retinal angle of incidence of the colorimeter beams.

    Science.gov (United States)

    Alpern, M; Kitahara, H; Fielder, G H

    1987-01-01

    Differences between W.D.W. chromaticities of monochromatic lights obtained with all colorimeter beams incident on the retina "off-axis" and those found for lights striking the retina normally have been studied throughout the visible spectrum on 4 normal trichromats. The results are inconsistent with: (i) the assumption in Weale's theories of the Stiles-Crawford hue shift that the sets of absorption spectra of the visual pigments catching normally and obliquely incident photons are identical, and (ii) "self-screening" explanations for the change in color with angle of incidence on the retina. The color matching functions of a protanomalous trichromat are inconsistent with the hypothesis that the absorption spectra of the visual pigments catching normally incident photons in his retina are those catching obliquely incident photons in the normal retina.

  4. Optimal micro-mirror tilt angle and sync mark design for digital micro-mirror device based collinear holographic data storage system.

    Science.gov (United States)

    Liu, Jinpeng; Horimai, Hideyoshi; Lin, Xiao; Liu, Jinyan; Huang, Yong; Tan, Xiaodi

    2017-06-01

    The collinear holographic data storage system (CHDSS) is a very promising storage system due to its large storage capacities and high transfer rates in the era of big data. The digital micro-mirror device (DMD) as a spatial light modulator is the key device of the CHDSS due to its high speed, high precision, and broadband working range. To improve the system stability and performance, an optimal micro-mirror tilt angle was theoretically calculated and experimentally confirmed by analyzing the relationship between the tilt angle of the micro-mirror on the DMD and the power profiles of diffraction patterns of the DMD at the Fourier plane. In addition, we proposed a novel chess board sync mark design in the data page to reduce the system bit error rate in circumstances of reduced aperture required to decrease noise and median exposure amount. It will provide practical guidance for future DMD based CHDSS development.

  5. The impact of changing solar screen rotation angle and its opening aspect ratios on Daylight Availability in residential desert buildings

    KAUST Repository

    Sherif, Ahmed H.

    2012-11-01

    In desert sunny clear-sky regions solar penetration can become excessive. This can cause non-uniform daylight distribution, glare and high solar heat gain, affecting both visual and thermal comfort. Shading devices, such as solar screens, were usually used to diffuse and prevent direct solar penetration into spaces. This paper investigates the impact of changing solar screen axial rotation angle and screen opening aspect ratio on daylighting performance in a typical residential living room space under the desert sunny clear-sky. The larger aim is to arrive at efficient solar screen designs that suit the different orientations.The study was divided into three consecutive phases. In phase one, the effect of the two parameters on Daylight Availability was tested. The solar screen was axially rotated by three different angles at 10° increments. Also, the aspect ratio of the screen opening in both horizontal and vertical directions was changed systematically. Simulation was conducted using the annual Daylight Dynamic Performance Metrics (DDPMs). In phase two, the Annual Daylight Glare Probability (DGP) metric was evaluated for the cases that were found adequate in phase one. In the third phase, the annual solar energy transmittance through the screen was calculated for the cases that achieved acceptable performance in the two previous phases in order to identify the more energy efficient screens.Solar screens with openings having horizontal aspect ratios were found to be the most effective, while those with vertical aspect ratios were achieved the lowest performance. In the North orientation, since almost all the cases that were tested in this research provided acceptable daylighting performance, the designer now have a variety of options to choose from. Preference should be given to screen openings of horizontal aspect ratios, especially the 12:1 and 18:1 (H:V) screens that achieved the best performance where 92% of the space was " daylit" in comparison with only 53

  6. Automatic Adviser on stationary devices status identification and anticipated change

    Science.gov (United States)

    Shabelnikov, A. N.; Liabakh, N. N.; Gibner, Ya M.; Pushkarev, E. A.

    2018-05-01

    A task is defined to synthesize an Automatic Adviser to identify the automation systems stationary devices status using an autoregressive model of changing their key parameters. An applied model type was rationalized and the research objects monitoring process algorithm was developed. A complex of mobile objects status operation simulation and prediction results analysis was proposed. Research results are commented using a specific example of a hump yard compressor station. The work was supported by the Russian Fundamental Research Fund, project No. 17-20-01040.

  7. Intra-articular knee temperature changes: ice versus cryotherapy device.

    Science.gov (United States)

    Warren, Todd A; McCarty, Eric C; Richardson, Airron L; Michener, Todd; Spindler, Kurt P

    2004-03-01

    Cryotherapy is commonly applied without research documenting the intra-articular (IA) temperature changes or subject discomfort between ice and a cryotherapy device. The null hypothesis is that no difference would be observed in IA temperature decline or subject tolerance between ice and the cryotherapy device in normal knees. Prospective, within-subject controlled clinical trial. Twelve subjects had IA temperature in suprapatellar pouch and skin recorded bilaterally after application of cryotherapy versus ice. Subject tolerance was recorded by 10-cm visual analog scale (VAS). Statistical evaluation was by Spearman's correlation analysis and paired, nonparametric Wilcoxon's signed rank test. Both significantly lowered (P cryotherapy) at 30 (3.3 degrees C/2.2 degrees C), 60 (12.8 degrees C/7.1 degrees C), and 90 (15.2 degrees C/9.7 degrees C) minutes. However, ice lowered the IA temperature significantly more than the cryotherapy device (P < 0.001) and was more painful by VAS at 30 and 60 minutes (P < 0.01). Both methods produced large declines in skin and IA temperatures. However, ice was more effective yet resulted in higher pain scores. The authors hypothesize that IA temperatures below a threshold are associated with increased perceived pain.

  8. Implant Angle Monitor System of MC3-II

    International Nuclear Information System (INIS)

    Sato, Fumiaki; Sano, Makoto; Nakaoka, Hiroaki; Fujii, Yoshito; Kudo, Tetuya; Nakanishi, Makoto; Koike, Masazumi; Fujino, Yasushi

    2008-01-01

    Precise implant angle control is required for the latest generation of ion implanters to meet further shrink semiconductor device requirements. Especially, the highest angle accuracy is required for Halo implant process of Logic devices. The Halo implant angle affects the device performance, because slight differences of beam divergence change the overlap profile towards the extension. Additionally, twist angle accuracy is demanded in case of channeling angle implant. Therefore monitoring beam angles and wafer twist angles is important. A new monitoring system for the MC3-II, SEN Corp.'s single wafer type medium current implanter has been developed. This paper describes the angle control performance and monitoring system of the MC3-II. For the twist angle control, we developed a wafer notch angle monitor. The system monitors the wafer notch image on the platen. And the notch angle variation is calculated by using image processing method. It is also able to adjust the notch angle according to the angle error. For the tilt angle control, we developed a vertical beam profile monitor. The monitor system can detect beam profile of vertical directions with horizontally scanning beam. It also measures beam angles of a tilt direction to a wafer. The system configuration and sample beam data are presented.

  9. Mercury's radius change estimates revisited using high incidence angle MESSENGER data

    Science.gov (United States)

    Di Achille, G.; Popa, C.; Massironi, M.; Ferrari, S.; Mazzotta Epifani, E.; Zusi, M.; Cremonese, G.; Palumbo, P.

    2012-04-01

    Estimates of Mercury's radius decrease obtained using the amount of strain recorded by tectonics on the planet range from 0.5 km to 2 km. These latter figures appear too low with respect to the radius contraction (up to 5-6 km) predicted by the most accredited studies based on thermo-mechanical evolution models. For this reason, it has been suggested that there may be hidden strain accommodated by features yet unseen on Mercury. Indeed, as it has been already cautioned by previous studies, the identification of tectonic features on Mercury might be largely biased by the lighting geometry of the used basemaps. This limitation might have affected the results of the extrapolations for estimating the radius change. In this study, we mapped tectonic features at the terminator thus using images acquired at high sun incidence angle (>50°) that represents the optimal condition for their observation. In fact, images with long shadows enhance the topography and texture of the surface and are ideal to detect tectonic structures. This favorable illumination conditions allowed us to infer reliable measurements of spatial distribution (i.e. frequency, orientation, and areal density) of tectonic features which can be used to estimate the average contractional strain and planetary radius decrease. We digitized tectonic structures within a region extending for an area of about 12 million sq. km (~16% of planet's surface). More than 1300 tectonic lineaments were identified and interpreted to be compressional features (i.e. lobate scarps, wrinkle ridges, and high relief ridges) with a total length of more than 12300 km. Assuming that the extensional strain is negligible within the area, the average contractional strain calculated for the survey area is ~0.21-0.28% (~0.24% for θ=30°). This strain, extrapolated to the entire surface, corresponds to a contraction in radius of about 2.5-3.4 km (~2.9 km for θ=30°). Interestingly, the values of contractional strain and radius decrease

  10. A Wireless Swing Angle Measurement Scheme Using Attitude Heading Reference System Sensing Units Based on Microelectromechanical Devices

    Directory of Open Access Journals (Sweden)

    Bingtuan Gao

    2014-11-01

    Full Text Available Feasible real-time swing angle measurement is significant to improve the efficiency and safety of industrial crane systems. This paper presents a wireless microelectromechanical system (MEMS-based swing angle measurement system. The system consists of two attitude heading reference system (AHRS sensing units with a wireless communication function, which are mounted on the hook (or payload and the jib (or base of the crane, respectively. With a combination of a three-axis accelerometer, a three-axis gyroscope and a three-axis magnetometer, the standard extended Kalman filter (EKF is used to estimate the desired orientation of the payload and the base. Wireless ZigBee communication is employed to transmit the orientation of the payload to the sensing unit mounted on the base, which measures the orientation of the base. Because several physical parameters from the payload to the base can be acquired from the original crane control system, the swing angles of the payload can be calculated based on the two measured orientation parameters together with the known physical parameters. Experiments were performed to show the feasibility and effectiveness of the proposed swing angle measurement system.

  11. Change in Visual Field Progression Following Treatment Escalation in Primary Open-angle Glaucoma.

    Science.gov (United States)

    Aptel, Florent; Bron, Alain M; Lachkar, Yves; Schweitzer, Cédric

    2017-10-01

    To evaluate the effect of treatment escalation on the rate of visual field progression in patients with primary open-angle glaucoma (POAG). Multicenter database study. We reviewed the electronic records of 171 patients with POAG under medical hypotensive treatment who underwent 5 consecutive visits 6 months apart before and after medical treatment escalation or additive laser trabeculoplasty. We calculated the rate of visual field progression (mean deviation change per year) before and after treatment escalation. The mean duration of follow-up was 5.1±0.5 years and the mean number of visual field examinations was 10.2±0.2. In 139 eyes with medical treatment escalation, the rate of progression was significantly reduced [from -0.57 to -0.29 dB/y; P=0.022; intraocular pressure (IOP) reduction 11.1%]. In detail, the rate of progression was significantly reduced after escalation from mono to dual therapy, dual to triple therapy, and from mono to triple therapy (-0.35 to -0.24 dB/y, P=0.018; -1.01 to -0.48 dB/y, P=0.038; -1.04 to -0.35 dB/y, P=0.020, respectively). In 32 eyes with additive laser trabeculoplasty, the rate of progression was significantly reduced (-0.60 to -0.24 dB/y; P=0.014; IOP reduction 9.4%). Medical treatment escalation or additive laser trabeculoplasty significantly reduced the rate of visual field progression in POAG. Larger IOP reduction has a greater probability of reducing glaucoma progression.

  12. Effect of the angle of apical resection on apical leakage, measured with a computerized fluid filtration device.

    Science.gov (United States)

    Garip, Hasan; Garip, Yıldız; Oruçoğlu, Hasan; Hatipoğlu, Seda

    2011-03-01

    We determined the effect of the angle of apical resection on apical leakage using a computerized fluid filtration meter with a laser system and a digital air pressure regulator in 46 extracted single-rooted human teeth. Orthograde endodontic treatment was performed. The root canals were prepared up to a size 50 K-type file with 17% EDTA solution (Roth International, Chicago, IL) and 5% NaOCl solution as the irrigant. Gates Glidden burs (Maillefer Instruments, Ballaigues, Switzerland) were used to flare the coronal two thirds of the canal. All canals were dried with paper points and then obturated using cold lateral condensation (except for the positive controls) of gutta-percha points and AH plus (Dentsply DeTrey, Konstanz, Germany). All 40 roots were sectioned 3 mm from the apex. Forty teeth were assigned randomly into 1 of 4 experimental groups of 10 teeth each: in group 1, the teeth were resected apically (90° angle) and the cavities were obturated with mineral trioxide aggregate (MTA); in group 2, after apical resection (90° angle), a root-end cavity was prepared using ultrasonic diamond retrotips and the cavities were obturated with MTA; in group 3, the teeth were resected apically (∼45° angle) and the cavities were obturated with MTA; and in group 4, after apical resection (∼45° angle), a root-end cavity was prepared using ultrasonic diamond retrotips and the cavities were obturated with MTA. An additional 6 teeth were used as controls (3 each, negative and positive controls). Apical leakage was measured using a computerized fluid filtration meter with a laser system. The mean apical microleakage was 2.0 ± 0.4 × 10(-4), 1.6 ± 0.6 × 10(-4), 1.6 ± 0.9 × 10(-4), and 1.8 ± 0.7 × 10(-4) μL/cmH(2)O/min(-1) at 1.2 atm, in groups 1 to 4, respectively. Although the mean apical microleakage was greater in group 1, the differences among the 4 groups were not statistically significant (P > .05). The results of these in vitro studies showed that when an

  13. Computational split-field finite-difference time-domain evaluation of simplified tilt-angle models for parallel-aligned liquid-crystal devices

    Science.gov (United States)

    Márquez, Andrés; Francés, Jorge; Martínez, Francisco J.; Gallego, Sergi; Álvarez, Mariela L.; Calzado, Eva M.; Pascual, Inmaculada; Beléndez, Augusto

    2018-03-01

    Simplified analytical models with predictive capability enable simpler and faster optimization of the performance in applications of complex photonic devices. We recently demonstrated the most simplified analytical model still showing predictive capability for parallel-aligned liquid crystal on silicon (PA-LCoS) devices, which provides the voltage-dependent retardance for a very wide range of incidence angles and any wavelength in the visible. We further show that the proposed model is not only phenomenological but also physically meaningful, since two of its parameters provide the correct values for important internal properties of these devices related to the birefringence, cell gap, and director profile. Therefore, the proposed model can be used as a means to inspect internal physical properties of the cell. As an innovation, we also show the applicability of the split-field finite-difference time-domain (SF-FDTD) technique for phase-shift and retardance evaluation of PA-LCoS devices under oblique incidence. As a simplified model for PA-LCoS devices, we also consider the exact description of homogeneous birefringent slabs. However, we show that, despite its higher degree of simplification, the proposed model is more robust, providing unambiguous and physically meaningful solutions when fitting its parameters.

  14. High-pressure, high-temperature magic angle spinning nuclear magnetic resonance devices and processes for making and using same

    Science.gov (United States)

    Hu, Jian Zhi; Hu, Mary Y.; Townsend, Mark R.; Lercher, Johannes A.; Peden, Charles H. F.

    2015-10-06

    Re-usable ceramic magic angle spinning (MAS) NMR rotors constructed of high-mechanic strength ceramics are detailed that include a sample compartment that maintains high pressures up to at least about 200 atmospheres (atm) and high temperatures up to about least about 300.degree. C. during operation. The rotor designs minimize pressure losses stemming from penetration over an extended period of time. The present invention makes possible a variety of in-situ high pressure, high temperature MAS NMR experiments not previously achieved in the prior art.

  15. Changes in the Lipidomic Profile of Aqueous Humor in Open-Angle Glaucoma

    DEFF Research Database (Denmark)

    Cabrerizo, Javier; Urcola, Javier A; Vecino, Elena

    2017-01-01

    PURPOSE: To identify and determine differences in lipid profiles of aqueous humor (AH) in patients with open-angle glaucoma (OAG). MATERIALS AND METHODS: The lipidomic profile of 10 samples of AH of patients with OAG and 10 controls was analyzed. Patients with a history of anterior segment surgery...

  16. Small-Angle Neutron Scattering Study of Structural Changes in Temperature-Sensitive Microgel Colloids

    NARCIS (Netherlands)

    Stieger, M.A.; Richtering, W.; Pedersen, J.S.; Lindner, P.

    2004-01-01

    The structure of temperature-sensitive poly(N-isopropylacrylamide) microgels in dilute suspension was investigated by means of small-angle neutron scattering. A direct modeling expression for the scattering intensity distribution was derived which describes very well the experimental data at all

  17. Effect of lordosis angle change after lumbar/lumbosacral fusion on sacrum angular displacement: a finite element study.

    Science.gov (United States)

    Mao, Ningfang; Shi, Jian; He, Dawei; Xie, Yang; Bai, Yushu; Wei, Xianzhao; Shi, Zhicai; Li, Ming

    2014-11-01

    To assess and characterize the sacrum angular displacements in response to lumbar lordosis after lumbar/lumbosacral fusion. A finite element model of the lower lumbar spine-pelvis was established and used to simulate the posterior fusion at L3-L5 and L4-S1. The lordosis angle in the fusion segments was set to five different conditions with respect to the intact model: 10° less than intact, 5° less than intact, same as intact, 5° more than intact, and 10° more than intact. Variations of the sacrum angular displacements with lordosis changes were analyzed under loading setting of axial compression, flexion, extension, lateral bending, and axial rotation. Compared with the intact lordosis, both increased and decreased lumbar lordosis angles caused the sacrum angular displacements to be increased. The lordosis angle increased by 10° induced the most substantial increase in sacrum angular displacements. In addition, the sacrum angular displacements of the L4-S1 fusion model at different lordosis angles were higher than those of the L3-L5 fusion model. The sacrum angular displacements occur as a result of the fusion surgery (L4-S1) and the changes in lumbar lordosis.

  18. Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices

    Directory of Open Access Journals (Sweden)

    Alberto Domínguez-Vicent

    2014-08-01

    Full Text Available Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D. Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera and the Pentacam HR (single Scheimpflug camera systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured with the Galilei G4 and the Pentacam HR, respectively. The mean white-to-white distance measured was 11.84 ± 0.31 mm and 11.90 ± 0.43 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Mean pupil diameters were measured as 3.22 ± 0.58 mm and 3.22 ± 0.52 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Finally, the mean anterior chamber angle was 34.30 ± 2.86 degrees when it was measured with the Galilei G4, and 39.26 ± 2.85 degrees when measured with the Pentacam HR. A comparative analysis revealed that the Galilei G4 yielded a significantly lower (P0.05 for both devices were obtained for the white-to-white distance measurements. Conclusion: The Galilei G4 and Pentacam HR Scheimpflug systems cannot be used interchangeably because they produce significant measurement differences.

  19. Simulating ecological changes caused by marine energy devices

    Science.gov (United States)

    Schuchert, Pia; Elsaesser, Bjoern; Pritchard, Daniel; Kregting, Louise

    2015-04-01

    Marine renewable energy from wave and tidal technology has the potential to contribute significantly globally to energy security for future generations. However common to both tidal and wave energy extraction systems is concern regarding the potential environmental consequences of the deployment of the technology as environmental and ecological effects are so far poorly understood. Ecological surveys and studies to investigate the environmental impacts are time consuming and costly and are generally reactive; a more efficient approach is to develop 2 and 3D linked hydrodynamic-ecological modelling which has the potential to be proactive and to allow forecasting of the effects of array installation. The objective of the study was to explore tools which can help model and evaluate possible far- and near field changes in the environment and ecosystem caused by the introduction of arrays of marine energy devices. Using the commercial software, MIKE by DHI, we can predict and model possible changes in the ecosystem. MIKE21 and ECOLab modelling software provide the opportunity to couple high level hydrodynamic models with process based ecological models and/or agent based models (ABM). The flow solutions of the model were determined in an idealised tidal basin with the dimensions similar to that of Strangford Lough, Northern Ireland, a body of water renowned for the location of the first grid-connected tidal turbine, SeaGen. In the first instance a simple process oriented ecological NPZD model was developed which are used to model marine and freshwater systems describing four state variables, Nutrient, Phytoplankton, Zooplankton and Detritus. The ecological model was run and evaluated under two hydrodynamic scenarios of the idealised basin. This included no tidal turbines (control) and an array of 55 turbines, an extreme scenario. Whilst an array of turbines has an effect on the hydrodynamics of the Lough, it is unlikely to see an extreme effect on the NPZD model

  20. Applicability of the two-angle differential method to response measurement of neutron-sensitive devices at the RCNP high-energy neutron facility

    Energy Technology Data Exchange (ETDEWEB)

    Masuda, Akihiko, E-mail: aki-masuda@aist.go.jp [National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Matsumoto, Tetsuro [National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Iwamoto, Yosuke [Japan Atomic Energy Agency (JAEA), 2-4 Shirakata, Tokai, Naka, Ibaraki 319-1195 (Japan); Hagiwara, Masayuki [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Satoh, Daiki; Sato, Tatsuhiko [Japan Atomic Energy Agency (JAEA), 2-4 Shirakata, Tokai, Naka, Ibaraki 319-1195 (Japan); Iwase, Hiroshi [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Yashima, Hiroshi [Research Reactor Institute, Kyoto University, 2-1010 Asashiro-nishi, Kumatori, Sennan, Osaka 590-0494 (Japan); Nakane, Yoshihiro [Japan Atomic Energy Agency (JAEA), 2-4 Shirakata, Tokai, Naka, Ibaraki 319-1195 (Japan); Nishiyama, Jun [Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro, Tokyo 152-8550 (Japan); Shima, Tatsushi; Tamii, Atsushi; Hatanaka, Kichiji [Research Center for Nuclear Physics (RCNP), Osaka University, 10-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Harano, Hideki [National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Nakamura, Takashi [Cyclotron and Radioisotope Center (CYRIC), Tohoku University, 6-3 Aramaki, Aoba, Sendai, Miyagi 980-8578 (Japan)

    2017-03-21

    Quasi-monoenergetic high-energy neutron fields induced by {sup 7}Li(p,n) reactions are used for the response evaluation of neutron-sensitive devices. The quasi-monoenergetic high-energy field consists of high-energy monoenergetic peak neutrons and unwanted continuum neutrons down to the low-energy region. A two-angle differential method has been developed to compensate for the effect of the continuum neutrons in the response measurements. In this study, the two-angle differential method was demonstrated for Bonner sphere detectors, which are typical examples of moderator-based neutron-sensitive detectors, to investigate the method's applicability and its dependence on detector characteristics. Experiments were performed under 96–387 MeV quasi-monoenergetic high-energy neutron fields at the Research Center for Nuclear Physics (RCNP), Osaka University. The measurement results for large high-density polyethylene (HDPE) sphere detectors agreed well with Monte Carlo calculations, which verified the adequacy of the two-angle differential method. By contrast, discrepancies were observed in the results for small HDPE sphere detectors and metal-induced sphere detectors. The former indicated that detectors that are particularly sensitive to low-energy neutrons may be affected by penetrating neutrons owing to the geometrical features of the RCNP facility. The latter discrepancy could be consistently explained by a problem in the evaluated cross-section data for the metals used in the calculation. Through those discussions, the adequacy of the two-angle differential method was experimentally verified, and practical suggestions were made pertaining to this method.

  1. Understanding nucleic acid structural changes by comparing wide-angle x-ray scattering (WAXS) experiments to molecular dynamics simulations

    Energy Technology Data Exchange (ETDEWEB)

    Pabit, Suzette A.; Katz, Andrea M.; Pollack, Lois [School of Applied and Engineering Physics, Cornell University, Ithaca, New York 14853 (United States); Tolokh, Igor S. [Department of Computer Science, Virginia Tech, Blacksburg, Virginia 24061 (United States); Drozdetski, Aleksander [Department of Physics, Virginia Tech, Blacksburg, Virginia 24061 (United States); Baker, Nathan [Pacific Northwest National Laboratory, Richland, Washington 99352 (United States); Onufriev, Alexey V. [Department of Computer Science, Virginia Tech, Blacksburg, Virginia 24061 (United States); Department of Physics, Virginia Tech, Blacksburg, Virginia 24061 (United States)

    2016-05-28

    Wide-angle x-ray scattering (WAXS) is emerging as a powerful tool for increasing the resolution of solution structure measurements of biomolecules. Compared to its better known complement, small angle x-ray scattering (SAXS), WAXS targets higher scattering angles and can enhance structural studies of molecules by accessing finer details of solution structures. Although the extension from SAXS to WAXS is easy to implement experimentally, the computational tools required to fully harness the power of WAXS are still under development. Currently, WAXS is employed to study structural changes and ligand binding in proteins; however, the methods are not as fully developed for nucleic acids. Here, we show how WAXS can qualitatively characterize nucleic acid structures as well as the small but significant structural changes driven by the addition of multivalent ions. We show the potential of WAXS to test all-atom molecular dynamics (MD) simulations and to provide insight into understanding how the trivalent ion cobalt(III) hexammine (CoHex) affects the structure of RNA and DNA helices. We find that MD simulations capture the RNA structural change that occurs due to addition of CoHex.

  2. Computer-aided surgical planner for a new bone deformity correction device using axis-angle representation.

    Science.gov (United States)

    Wu, Ying Ying; Plakseychuk, Anton; Shimada, Kenji

    2014-11-01

    Current external fixators for distraction osteogenesis (DO) are unable to correct all types of deformities in the lower limb and are difficult to use because of the lack of a pre-surgical planning system. We propose a DO system that consists of a surgical planner and a new, easy-to-setup unilateral fixator that not only corrects all lower limb deformity, but also generates the contralateral/predefined bone shape. Conventionally, bulky constructs with six or more joints (six degrees of freedom, 6DOF) are needed to correct a 3D deformity. By applying the axis-angle representation, we can achieve that with a compact construct with only two joints (2DOF). The proposed system makes use of computer-aided design software and computational methods to plan and simulate the planned procedure. Results of our stress analysis suggest that the stiffness of our proposed fixator is comparable to that of the Orthofix unilateral external fixator. We tested the surgical system on a model of an adult deformed tibia and the resulting bone trajectory deviates from the target bone trajectory by 1.8mm, which is below our defined threshold error of 2mm. We also extracted the transformation matrix that defines the deformity from the bone model and simulated the planned procedure. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  3. Verification of anti-fatigue effect of anserine by angle fatigue indicator based on median frequency changes of electromyograms

    Directory of Open Access Journals (Sweden)

    Hirohisa Kishi

    2013-10-01

    Full Text Available ABSTRACT: Objective: Anserine, which is abundant in avian species and in a wide range of fish such as bonito and tuna, is reported to have anti-fatigue effect. Although chicken soup and bonito soup is traditionally used to recover from physical fatigue, it is generally difficult to verify the effect in humans. This study was to directly demonstrate the anti-fatigue effect of oceanic anserine in humans. Methods: Edible-grade anserine was purified from fish extract with food-grade reagents. Subjects were 17 healthy male volunteers (35.5 ± 5 yr., 75.5 ± 5.0 kg. Each subject performed the isometric exercise tolerance test (ETT on the rectus femoris muscle twice (Ex_1, Ex_2 both for anserine and water conditions on a different day. Median frequency changes (MDF during Functional Foods in Health and Disease 2013; 3(10 389-399 ETTs were calculated and regression curves were calculated over a frequency range of 21-214 Hz. The difference, or angle, between the slopes of Ex_1 and Ex_2 MDF regression curves, which corresponds to the degree of fatigue, was defined as an angle fatigue index and compared between anserine and water intake conditions. Results: MDF decreased during ETTs in most patients and the slopes of regression curves were larger in Ex_2 than in Ex_1. Angle fatigue index for water (control was significantly larger than that for anserine (p<0.01, paired t-test, n=17. The result indicates that anserine have an anti-fatigue effect on skeletal muscle in humans. Conclusions: We proposed the angle fatigue index as a touchstone of the muscle fatigue. The index indicates that anserine is effective to reduce the muscle fatigue in humans.

  4. Design and Experimental Verification of Chang'E-3 Moon-night Survival Device for APXS

    Science.gov (United States)

    Deng-yi, Chen; Jian, Wu; Yi-ming, Hu; Jin, Chang; Yi-zhong, Gong; Ming-sheng, Cai; Huan-yu, Wang; Jia-yu, Zhang; Xing-zhu, Cui; Jin-zhou, Wang

    2016-07-01

    The Active Particle X-ray Spectrometer (APXS) is one of the 4 scientific payloads of Chang'E-3 (CE-3) Lunar Rover, of which the scientific object is to identify the elements of lunar soil and rock samples by a carried radioactive source to trigger and detect the characteristic X-ray from them. According to the extreme temperature environment of the APXS and under the restriction of limited resources, this paper presents the design and analysis of the moon-night survival device RHU (radioisotope heating unit) for the APXS, and describes the corresponding environmental tests on its structure dynamics and moon-night survival. Finally, its reinstallation on the launch tower and the preliminary result of its on-orbit operation are introduced.

  5. Structural changes in C–S–H gel during dissolution: Small-angle neutron scattering and Si-NMR characterization

    Energy Technology Data Exchange (ETDEWEB)

    Trapote-Barreira, Ana, E-mail: anatrapotebarreira@gmail.com [Institute of Environmental Assessment and Water Research (IDAEA), Barcelona 08034, Catalonia (Spain); Porcar, Lionel [National Institute of Standards and Technology (NIST), Gaithersburg, MD 20899 (United States); Large Scale Structure Group, Institut Laue Langevin, Grenoble (France); Cama, Jordi; Soler, Josep M. [Institute of Environmental Assessment and Water Research (IDAEA), Barcelona 08034, Catalonia (Spain); Allen, Andrew J. [National Institute of Standards and Technology (NIST), Gaithersburg, MD 20899 (United States)

    2015-06-15

    Flow-through experiments were conducted to study the calcium–silicate–hydrate (C–S–H) gel dissolution kinetics. During C–S–H gel dissolution the initial aqueous Ca/Si ratio decreases to reach the stoichiometric value of the Ca/Si ratio of a tobermorite-like phase (Ca/Si = 0.83). As the Ca/Si ratio decreases, the solid C–S–H dissolution rate increases from (4.5 × 10{sup −} {sup 14} to 6.7 × 10{sup −} {sup 12}) mol m{sup −} {sup 2} s{sup −} {sup 1}. The changes in the microstructure of the dissolving C–S–H gel were characterized by small-angle neutron scattering (SANS) and {sup 29}Si magic-angle-spinning nuclear magnetic resonance ({sup 29}Si-MAS NMR). The SANS data were fitted using a fractal model. The SANS specific surface area tends to increase with time and the obtained fit parameters reflect the changes in the nanostructure of the dissolving solid C–S–H within the gel. The {sup 29}Si MAS NMR analyses show that with dissolution the solid C–S–H structure tends to a more ordered tobermorite structure, in agreement with the Ca/Si ratio evolution.

  6. General shape and hapten-induced conformational changes of pig anti-dinitrophenyl antibody. A small-angle scattering study

    International Nuclear Information System (INIS)

    Cher, L.; Gladkikh, I.A.; Franek, F.; Kunchenko, A.B.; Ostanevich, Yu.M.

    1980-01-01

    Pig anti-dinitrophenyl antibodies were studied by neutron and X-ray small-angle scattering. Observed scattering curves show that the shapes of two antibody types, precipitating and non-precipitating, are similar, however the latter being more compact. A hapten binding induced conformational change of antibody is observed. This conformational change might be described as a contraction of the whole molecule via similarity transformation. The spatial models of pig antibody molecule based on the existing experimental data were designed. Most probable models have a cavity in the Fsub(c) part and the Fsub(ab) parts are either fully extended or slightly bent down to the Fsub(c) part

  7. Device for automatic filter changing. Einrichtung zum selbsttaetigen Wechseln eines Filters

    Energy Technology Data Exchange (ETDEWEB)

    Matschoss, V; Naschwitz, A; Wild, H

    1984-01-05

    A filter is moved from a store to an aerosol pipe by a lifting device and is clamped there. At the end of the operating period, the lifting device moves a new filter to a parking place. Control is from limit switches of the lifting, clamping and thrust devices and the position control of the store is by the limit switches. The filter changing device is enclosed in a gastight case, prevents blockage of a filter and makes it possible to set a certain operating period, to change the filter without interrupting the aerosol flow and to measure each filter in the sequence of operation outside the aerosol flow.

  8. Apparatus for Changing the Attack Angle of a Cavitator on a Supercavatating Underwater Research Model

    Science.gov (United States)

    2005-07-18

    the Invention 14 The present invention generally relates to an apparatus 15 for changing the attack of a cavitator on a supercavitating 16 underwater...research model. 17 2. Description of the Prior Art 18 Supercavitating underwater vehicles and projectiles are 19 known in the art. One such... supercavitating underwater 20 projectile is described in Harkins et al., U.S. Patent No. 21 5,955,698. This projectile uses a supercavitating nose 22 section that

  9. Imaging Fracture Networks Using Angled Crosshole Seismic Logging and Change Detection Techniques

    Science.gov (United States)

    Knox, H. A.; Grubelich, M. C.; Preston, L. A.; Knox, J. M.; King, D. K.

    2015-12-01

    We present results from a SubTER funded series of cross borehole geophysical imaging efforts designed to characterize fracture zones generated with an alternative stimulation method, which is being developed for Enhanced Geothermal Systems (EGS). One important characteristic of this stimulation method is that each detonation will produce multiple fractures without damaging the wellbore. To date, we have collected six full data sets with ~30k source-receiver pairs each for the purposes of high-resolution cross borehole seismic tomographic imaging. The first set of data serves as the baseline measurement (i.e. un-stimulated), three sets evaluate material changes after fracture emplacement and/or enhancement, and two sets are used for evaluation of pick error and seismic velocity changes attributable to changing environmental factors (i.e. saturation due to rain/snowfall in the shallow subsurface). Each of the six datasets has been evaluated for data quality and first arrivals have been picked on nearly 200k waveforms in the target area. Each set of data is then inverted using a Vidale-Hole finite-difference 3-D eikonal solver in two ways: 1) allowing for iterative ray tracing and 2) with fixed ray paths determined from the test performed before the fracture stimulation of interest. Utilizing these two methods allows us to compare and contrast the results from two commonly used change detection techniques. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  10. Increased Seat Dump Angle in a Manual Wheelchair Is Associated With Changes in Thoracolumbar Lordosis and Scapular Kinematics During Propulsion.

    Science.gov (United States)

    Cloud, Beth A; Zhao, Kristin D; Ellingson, Arin M; Nassr, Ahmad; Windebank, Anthony J; An, Kai-Nan

    2017-10-01

    To quantify and compare spinal curvature and shoulder kinematics throughout the manual wheelchair (MWC) propulsion cycle for individuals with spinal cord injury (SCI) who were seated at 2 different seat dump angles. Single-group, repeated-measures study. Academic medical center. Individuals (N=28) with SCI or spinal cord disease who used MWCs completed a telephone screening, and 21 of them were eligible and completed the study. Participants' personal MWCs were modified to have seat dump angles of 0° or 14°, with a vertical backrest. Participants completed at least 3 propulsion cycles in each condition, during which spine and shoulder motion data were collected with fiberoptic and electromagnetic sensors, respectively. Thoracolumbar spinal curvature, glenohumeral kinematics, and scapulothoracic kinematics at the start of push (SP), mid-push (MP), end of push (EP), and mid-recovery. Participants had significantly less lordosis in the 14° condition for all propulsion events. Median differences ranged from 2.0° to 4.6°. Lordosis differences were more pronounced in those with low SCI. Scapulothoracic internal rotation was increased in the 14° condition at SP and MP (mean differences, 2.5° and 2.7°, respectively). Relative downward rotation increased in the 14° condition at SP and MP (mean differences, 2.4° and 2.1°, respectively). Scapulothoracic differences were more pronounced in those with high SCI. No glenohumeral rotations were significantly different between the conditions. Scapulothoracic kinematics and spinal curvature differences during propulsion may be associated with the position of other body segments or postural stability. Because no differences were observed at the glenohumeral joint, the risk of subacromial impingement may not be affected by this seat angle change. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  11. The effect of ball impact location on racket and forearm joint angle changes for one-handed tennis backhand groundstrokes.

    Science.gov (United States)

    King, Mark; Hau, Agnes; Blenkinsop, Glen

    2017-07-01

    Recreational tennis players tend to have higher incidence of tennis elbow, and this has been hypothesised to be related to one-handed backhand technique and off-centre ball impacts on the racket face. This study aimed to investigate for a range of participants the effect of off-longitudinal axis and off-lateral axis ball-racket impact locations on racket and forearm joint angle changes immediately following impact in one-handed tennis backhand groundstrokes. Three-dimensional racket and wrist angular kinematic data were recorded for 14 university tennis players each performing 30 "flat" one-handed backhand groundstrokes. Off-longitudinal axis ball-racket impact locations explained over 70% of the variation in racket rotation about the longitudinal axis and wrist flexion/extension angles during the 30 ms immediately following impact. Off-lateral axis ball-racket impact locations had a less clear cut influence on racket and forearm rotations. Specifically off-longitudinal impacts below the longitudinal axis forced the wrist into flexion for all participants with there being between 11° and 32° of forced wrist flexion for an off-longitudinal axis impact that was 1 ball diameter away from the midline. This study has confirmed that off-longitudinal impacts below the longitudinal axis contribute to forced wrist flexion and eccentric stretch of the wrist extensors and there can be large differences in the amount of forced wrist flexion from individual to individual and between strokes with different impact locations.

  12. Fundamental changes of granular flows dynamics, deposition and erosion processes at high slope angles: insights from laboratory experiments.

    Science.gov (United States)

    Farin, Maxime; Mangeney, Anne; Roche, Olivier

    2014-05-01

    Geophysical granular flows commonly interact with their substrate in various ways depending on the mechanical properties of the underlying material. Granular substrates, resulting from deposition of earlier flows or various geological events, are often eroded by avalanches [see Hungr and Evans, 2004 for review]. The entrainment of underlying debris by the flow is suspected to affect flow dynamics because qualitative and quantitative field observations suggest that it can increase the flow velocity and deposit extent, depending on the geological setting and flow type [Sovilla et al., 2006; Iverson et al., 2011]. Direct measurement of material entrainment in nature, however, is very difficult. We conducted laboratory experiments on granular column collapse over an inclined channel with and without an erodible bed of granular material. The controlling parameters were the channel slope angle, the granular column volume and its aspect ratio (i.e. height over length), the inclination of the column with respect to the channel base, the channel width, and the thickness and compaction of the erodible bed. For slope angles below a critical value θc, between 10° and 16°, the runout distance rf is proportional to the initial column height h0 and is unaffected by the presence of an erodible bed. On steeper slopes, the flow dynamics change fundamentally since a last phase of slow propagation develops at the end of the flow front deceleration, and prolongates significantly the flow duration. This phase has similar characteristics that steady, uniform flows. The slow propagation phase lasts longer for increasing slope angle, column volume, column inclination with respect to the slope, and channel width, and for decreasing column aspect ratio. It is however independent of the maximum front velocity and, on an erodible bed, of the maximum depth of excavation within the bed. Both on rigid and erodible beds, the increase of the slow propagation phase duration has a crucial effect

  13. Influence of surgical implantation angle of left ventricular assist device outflow graft and management of aortic valve opening on the risk of stroke in heart failure patients

    Science.gov (United States)

    Chivukula, V. Keshav; McGah, Patrick; Prisco, Anthony; Beckman, Jennifer; Mokadam, Nanush; Mahr, Claudius; Aliseda, Alberto

    2016-11-01

    Flow in the aortic vasculature may impact stroke risk in patients with left ventricular assist devices (LVAD) due to severely altered hemodynamics. Patient-specific 3D models of the aortic arch and great vessels were created with an LVAD outflow graft at 45, 60 and 90° from centerline of the ascending aorta, in order to understand the effect of surgical placement on hemodynamics and thrombotic risk. Intermittent aortic valve opening (once every five cardiac cycles) was simulated and the impact of this residual native output investigated for the potential to wash out stagnant flow in the aortic root region. Unsteady CFD simulations with patient-specific boundary conditions were performed. Particle tracking for 10 cardiac cycles was used to determine platelet residence times and shear stress histories. Thrombosis risk was assessed by a combination of Eulerian and Lagrangian metrics and a newly developed thrombogenic potential metric. Results show a strong influence of LVAD outflow graft angle on hemodynamics in the ascending aorta and consequently on stroke risk, with a highly positive impact of aortic valve opening, even at low frequencies. Optimization of LVAD implantation and management strategies based on patient-specific simulations to minimize stroke risk will be presented

  14. Phase change heat transfer device for process heat applications

    International Nuclear Information System (INIS)

    Sabharwall, Piyush; Patterson, Mike; Utgikar, Vivek; Gunnerson, Fred

    2010-01-01

    The next generation nuclear plant (NGNP) will most likely produce electricity and process heat, with both being considered for hydrogen production. To capture nuclear process heat, and transport it to a distant industrial facility requires a high temperature system of heat exchangers, pumps and/or compressors. The heat transfer system is particularly challenging not only due to the elevated temperatures (up to ∼1300 K) and industrial scale power transport (≥50 MW), but also due to a potentially large separation distance between the nuclear and industrial plants (100+ m) dictated by safety and licensing mandates. The work reported here is the preliminary analysis of two-phase thermosyphon heat transfer performance with alkali metals. A thermosyphon is a thermal device for transporting heat from one point to another with quite extraordinary properties. In contrast to single-phased forced convective heat transfer via 'pumping a fluid', a thermosyphon (also called a wickless heat pipe) transfers heat through the vaporization/condensing process. The condensate is further returned to the hot source by gravity, i.e., without any requirement of pumps or compressors. With this mode of heat transfer, the thermosyphon has the capability to transport heat at high rates over appreciable distances, virtually isothermally and without any requirement for external pumping devices. Two-phase heat transfer by a thermosyphon has the advantage of high enthalpy transport that includes the sensible heat of the liquid, the latent heat of vaporization, and vapor superheat. In contrast, single-phase forced convection transports only the sensible heat of the fluid. Additionally, vapor-phase velocities within a thermosyphon are much greater than single-phase liquid velocities within a forced convective loop. Thermosyphon performance can be limited by the sonic limit (choking) of vapor flow and/or by condensate entrainment. Proper thermosyphon requires analysis of both.

  15. Effects of particle's off-axis position, shape, orientation and entry position on resistance changes of micro Coulter counting devices

    International Nuclear Information System (INIS)

    Qin, Zhenpeng; Zhe, Jiang; Wang, Guo-Xiang

    2011-01-01

    With the recent advance in micro/nano-fabrication technology, micro Coulter counters have been widely used in detecting and characterizing micro- and nanoscale objects. In this paper, the electrical resistance change during translocation of a non-conducting particle through a channel is studied numerically. The numerical results are validated by proven analytical results available in the literature. The effects of particle's off-axis position, shape and orientation, and entry position are studied for particles with a large dynamic range. From the numerical results, a new fitted correlation is proposed that can accurately predict the resistance change caused by off-axis spherical particles regardless of their size. The shape and orientation effects of the electrical resistance change are studied by changing the axis ratio of spheroid particles and their orientation angles. Results show that a particle's shape and orientation have a significant influence on the resistance change. Simulation of an entry effect indicates that a particle starts to induce a resistance change before it enters the channel and still causes a resistance change even after the particle exits the channel completely. This study will offer some guidelines in designing and implementing Coulter counting devices and experiments, and provide insights into explaining experimental results

  16. Adoption of Mobile Devices in Teaching: Changes in Teacher Beliefs, Attitudes and Anxiety

    Science.gov (United States)

    Chiu, Thomas K. F.; Churchill, Daniel

    2016-01-01

    Beliefs, attitudes and anxiety levels of schoolteachers are important factors influencing the acceptance, adoption and integration of mobile devices in teaching. To understand how to sustain device use, we need to understand what influences teachers and how such factors can change. We adopted a quasi-experimental design using pre- and…

  17. Changing Lenses: Using participatory photography for wide-angle intergroup perspectives on peace and conflict for social change

    OpenAIRE

    Tan de Bibiana, Marcus

    2017-01-01

    The potential for art in peacebuilding has shown success but not complete acceptance in the peacebuilding field. Participatory photography’s method of photovoice has shown effective as a unique participatory action research tool able to allow users to communicate deeply on sensitive subjects with potential to influence larger social change. Participatory photography programs involving intergroup conflict or tensions presents an important relational component for practitioners and stakeholders...

  18. Process and device for change of catalyst in tube reactors

    International Nuclear Information System (INIS)

    Fedders, H.; Cremer, P.; Erben, R.

    1985-01-01

    The change of catalyst in narrow reactor tubes with a height: diameter ratio of at least 30:1 is done by the catalyst filling being driven out against the force of gravity using a pulsating liquid flow. Pauses in the flow of between 0.1 to 1 sec between flow periods of 2 to 20 secs are useful. (orig./PW) [de

  19. A design handbook for phase change thermal control and energy storage devices. [selected paraffins

    Science.gov (United States)

    Humphries, W. R.; Griggs, E. I.

    1977-01-01

    Comprehensive survey is given of the thermal aspects of phase change material devices. Fundamental mechanisms of heat transfer within the phase change device are discussed. Performance in zero-g and one-g fields are examined as it relates to such a device. Computer models for phase change materials, with metal fillers, undergoing conductive and convective processes are detailed. Using these models, extensive parametric data are presented for a hypothetical configuration with a rectangular phase change housing, using straight fins as the filler, and paraffin as the phase change material. These data are generated over a range of realistic sizes, material properties, and thermal boundary conditions. A number of illustrative examples are given to demonstrate use of the parametric data. Also, a complete listing of phase change material property data are reproduced herein as an aid to the reader.

  20. Velopharyngeal changes after maxillary distraction in cleft patients using a rigid external distraction device: A retrospective study.

    Science.gov (United States)

    Taha, Mahasen; Elsheikh, Yasser M

    2016-11-01

     To evaluate early and late velopharyngeal changes in cleft lip and palate (CLP) patients after use of the Rigid External Distractor (RED) device and to correlate these changes to the amount of maxillary advancement.  Thirty Class III CLP patients were included in the study. Maxillary advancement was performed using the RED device in combination with titanium miniplates and screws for anchorage. Lateral cephalograms, nasometer, and nasopharyngoscope records were taken before distraction, immediately after distraction, and 1 year after distraction. A paired t-test was used to detect differences at P maxillary distraction (P  =  .0001). Statistically significant increases in nasopharyngeal and oropharyngeal depths, velar angle, and need ratio were also found (P  =  .0001). Nasalance scores showed a significant increase (P  =  .008 for nasal text and .044 for oral text). A significant positive correlation was observed between the amount of maxillary advancement and the increase in nasopharyngeal depth and hypernasality (P  =  .012 and .026, respectively).  Nasopharyngeal function was deteriorated after maxillary advancement in CLP patients. There was a significant positive correlation between the amount of maxillary advancement and the increase in nasopharyngeal depth and hypernasality.

  1. Counterion Association and Structural Conformation Change of Charged PAMAM Dendrimer in Aqueous Solutions Revealed by Small Angle Neutron Scattering

    International Nuclear Information System (INIS)

    Chen, Wei-Ren

    2009-01-01

    Our previous study of the structure change of poly(amidoamine) starburst dendrimers (PAMAM) dendrimer of generation 5 (G5) have demonstrated that although the overall molecular size is practically unaffected by increasing DCl concentration, a configurational transformation, from a diffusive density profile to a more uniform density distribution, is clearly observed. In the current paper, the focus is placed on understanding the effect of counterion identity on the inter-molecular structure and the conformational properties by studying the effect due to DBr using small angle neutron scattering (SANS) and integral equation theory. While the overall molecular size is found to be essentially unaffected by the change in the pD of solutions, it is surprising that the intra-molecular configurational transformation is not observed when DBr is used. The overall effective charge of a dendrimer is nearly the same for 1, the effect of counterion identity becomes significant, the effective charge carried by a charged G5 PAPAM protonated by DBr becomes smaller than that of solutions with DCl. As a consequence, a counterion identity dependence of counterion association is revealed: Under the same level of molecular protonation, the specific counterion association, which is defined as the ratio of bound chloride anions to positively charged amines per molecule, is larger for the G5 PAMAM dendrimer charged by DBr than the one by DCl.

  2. Changes of visual-field global indices after cataract surgery in primary open-angle glaucoma patients.

    Science.gov (United States)

    Seol, Bo Ram; Jeoung, Jin Wook; Park, Ki Ho

    2016-11-01

    To determine changes of visual-field (VF) global indices after cataract surgery and the factors associated with the effect of cataracts on those indices in primary open-angle glaucoma (POAG) patients. A retrospective chart review of 60 POAG patients who had undergone phacoemulsification and intraocular lens insertion was conducted. All of the patients were evaluated with standard automated perimetry (SAP; 30-2 Swedish interactive threshold algorithm; Carl Zeiss Meditec Inc.) before and after surgery. VF global indices before surgery were compared with those after surgery. The best-corrected visual acuity, intraocular pressure (IOP), number of glaucoma medications before surgery, mean total deviation (TD) values, mean pattern deviation (PD) value, and mean TD-PD value were also compared with the corresponding postoperative values. Additionally, postoperative peak IOP and mean IOP were evaluated. Univariate and multivariate logistic regression analyses were performed to identify the factors associated with the effect of cataract on global indices. Mean deviation (MD) after cataract surgery was significantly improved compared with the preoperative MD. Pattern standard deviation (PSD) and visual-field index (VFI) after surgery were similar to those before surgery. Also, mean TD and mean TD-PD were significantly improved after surgery. The posterior subcapsular cataract (PSC) type showed greater MD changes than did the non-PSC type in both the univariate and multivariate logistic regression analyses. In the univariate logistic regression analysis, the preoperative TD-PD value and type of cataract were associated with MD change. However, in the multivariate logistic regression analysis, type of cataract was the only associated factor. None of the other factors was associated with MD change. MD was significantly affected by cataracts, whereas PSD and VFI were not. Most notably, the PSC type showed better MD improvement compared with the non-PSC type after cataract surgery

  3. Fundamental change of granular flows dynamics, deposition and erosion processes at sufficiently high slope angles: insights from laboratory experiments

    Science.gov (United States)

    Farin, M.; Mangeney, A.; Roche, O.

    2013-12-01

    Geophysical granular flows commonly interact with their substrate in various ways depending on the mechanical properties of the underlying material. Granular substrates, resulting from deposition of earlier flows or various geological events, are often eroded by avalanches [see Hungr and Evans, 2004 for review]. The entrainment of underlying debris by the flow is suspected to affect flow dynamics because qualitative and quantitative field observations suggest that it can increase the flow velocity and deposit extent, depending on the geological setting and flow type [Sovilla et al., 2006; Iverson et al., 2011]. Direct measurement of material entrainment in nature, however, is very difficult. We conducted laboratory experiments on granular column collapse over an inclined channel with and without an erodible bed of granular material. The controlling parameters were the channel slope angle, the granular column volume and its aspect ratio (i.e. height over length), the inclination of the column with respect to the channel base, the channel width, and the thickness and compaction of the erodible bed. For slope angles below a critical value θc, between 10° and 16°, the runout distance rf is proportional to the initial column height h0 and is unaffected by the presence of an erodible bed. On slopes greater than θc, the flow dynamics change fundamentally since a last phase of slow propagation develops at the end of the flow front deceleration, and prolongates significantly the flow duration. This phase has similar characteristics that steady, uniform flows. The slow propagation phase lasts longer for increasing column volume, column inclination with respect to the slope, and channel width, and for decreasing column aspect ratio. It is however independent of the maximum front velocity and, on an erodible bed, of the maximum depth of excavation within the bed. Both on rigid and erodible beds, the increase of the slow propagation phase duration has a crucial effect on

  4. Correlation between hindfoot joint three-dimensional kinematics and the changes of the medial arch angle in stage II posterior tibial tendon dysfunction flatfoot.

    Science.gov (United States)

    Zhang, Yi-Jun; Xu, Jian; Wang, Yue; Lin, Xiang-Jin; Ma, Xin

    2015-02-01

    The aim of this study was to explore the correlation between the kinematics of the hindfoot joint and the medial arch angle change in stage II posterior tibial tendon dysfunction flatfoot three-dimensionally under loading. Computed tomography (CT) scans of 12 healthy feet and 12 feet with stage II posterior tibial tendon dysfunction flatfoot were taken both in non- and full-body-weight-bearing condition. The CT images of the hindfoot bones were reconstructed into three-dimensional models with Mimics and Geomagic reverse engineering software. The three-dimensional changes of the hindfoot joint were calculated to determine their correlation to the medial longitudinal arch angle. The medial arch angle change was larger in stage II posterior tibial tendon dysfunction flatfoot compared to that in healthy foot under loading. The rotation and translation of the talocalcaneal joint, the talonavicular joint and the calcanocuboid joint had little influence on the change of the medial arch angle in healthy foot. However, the eversion of the talocalcaneal joint, the proximal translation of the calcaneus relative to the talus and the dorsiflexion of talonavicular joint could increase the medial arch angle in stage II posterior tibial tendon dysfunction flatfoot under loading. Joint instability occurred in patients with stage II posterior tibial tendon dysfunction flatfoot under loading. Limitation of over movement of the talocalcaneal joint and the talonavicular joint may help correct the medial longitudinal arch in stage II posterior tibial tendon dysfunction flatfoot. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Changes in multi-segment foot biomechanics with a heat-mouldable semi-custom foot orthotic device

    Directory of Open Access Journals (Sweden)

    Ferber Reed

    2011-06-01

    Full Text Available Abstract Background Semi-custom foot orthoses (SCO are thought to be a cost-effective alternative to custom-made devices. However, previous biomechanical research involving either custom or SCO has only focused on rearfoot biomechanics. The purpose of this study was therefore to determine changes in multi-segment foot biomechanics during shod walking with and without an SCO. We chose to investigate an SCO device that incorporates a heat-moulding process, to further understand if the moulding process would significantly alter rearfoot, midfoot, or shank kinematics as compared to a no-orthotic condition. We hypothesized the SCO, whether moulded or non-moulded, would reduce peak rearfoot eversion, tibial internal rotation, arch deformation, and plantar fascia strain as compared to the no-orthoses condition. Methods Twenty participants had retroreflective markers placed on the right limb to represent forefoot, midfoot, rearfoot and shank segments. 3D kinematics were recorded using an 8-camera motion capture system while participants walked on a treadmill. Results Plantar fascia strain was reduced by 34% when participants walked in either the moulded or non-moulded SCO condition compared to no-orthoses. However, there were no significant differences in peak rearfoot eversion, tibial internal rotation, or medial longitudinal arch angles between any conditions. Conclusions A semi-custom moulded orthotic does not control rearfoot, shank, or arch deformation but does, however, reduce plantar fascia strain compared to walking without an orthoses. Heat-moulding the orthotic device does not have a measurable effect on any biomechanical variables compared to the non-moulded condition. These data may, in part, help explain the clinical efficacy of orthotic devices.

  6. 78 FR 69694 - Changing Regulatory and Reimbursement Paradigms for Medical Devices in the Treatment of Obesity...

    Science.gov (United States)

    2013-11-20

    ...] Changing Regulatory and Reimbursement Paradigms for Medical Devices in the Treatment of Obesity and... Administration (FDA) is announcing a public workshop entitled ``Changing Regulatory and Reimbursement Paradigms... information on the AGA Web site. If you need special accommodations due to a disability, please contact...

  7. Scoliosis angle

    International Nuclear Information System (INIS)

    Marklund, T.

    1978-01-01

    The most commonly used methods of assessing the scoliotic deviation measure angles that are not clearly defined in relation to the anatomy of the patient. In order to give an anatomic basis for such measurements it is proposed to define the scoliotic deviation as the deviation the vertebral column makes with the sagittal plane. Both the Cobb and the Ferguson angles may be based on this definition. The present methods of measurement are then attempts to measure these angles. If the plane of these angles is parallel to the film, the measurement will be correct. Errors in the measurements may be incurred by the projection. A hypothetical projection, called a 'rectified orthogonal projection', is presented, which correctly represents all scoliotic angles in accordance with these principles. It can be constructed in practice with the aid of a computer and by performing measurements on two projections of the vertebral column; a scoliotic curve can be represented independent of the kyphosis and lordosis. (Auth.)

  8. Do peak torque angles of muscles change following anterior cruciate ligament reconstruction using hamstring or patellar tendon graft?

    Science.gov (United States)

    Yosmaoğlu, Hayri Baran; Baltacı, Gül; Sönmezer, Emel; Özer, Hamza; Doğan, Deha

    2017-12-01

    This study aims to compare the effects of anterior cruciate ligament (ACL) reconstruction using autogenous hamstring or patellar tendon graft on the peak torque angle. The study included 132 patients (103 males, 29 females; mean age 29±9 year) who were performed ACL reconstruction with autogenous hamstring or patellar tendon graft. The peak torque angles in the quadriceps and hamstring muscles were recorded using an isokinetic dynamometer. Angle of peak knee flexion torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the hamstring tendon group. Angle of peak knee extension torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the patellar tendon group. There were no statistically significant differences in the flexion and extension peak torque angles between the operated and nonoperated knees at 60°/second in both groups. The angle of peak torque at relatively high angular velocities is affected after ACL reconstruction in patients with hamstring or patellar tendon grafts. The graft donor site directly influences this parameter. This finding may be important for clinicians in terms of preventing re-injury.

  9. Study of change in dispersion and orientation of clay platelets in a polymer nanocomposite during tensile test by variostage small-angle X-ray scattering

    CSIR Research Space (South Africa)

    Bandyopadhyay, J

    2012-04-01

    Full Text Available To understand the change in dispersion and orientation of clay platelets in three-dimensional space during tensile test, neat polymer and its nanocomposite samples were studied by small- and wide-angle X-ray scattering (SWAXS). The samples after...

  10. Do post-operative changes of neck-shaft angle and femoral component anteversion have an effect on clinical outcome following uncemented total hip arthroplasty?

    Science.gov (United States)

    Müller, M; Abdel, M P; Wassilew, G I; Duda, G; Perka, C

    2015-12-01

    The accurate reconstruction of hip anatomy and biomechanics is thought to be important in achieveing good clinical outcomes following total hip arthroplasty (THA). To this end some newer hip designs have introduced further modularity into the design of the femoral component such that neck-shaft angle and anteversion, which can be adjusted intra-operatively. The clinical effect of this increased modularity is unknown. We have investigated the changes in these anatomical parameters following conventional THA with a prosthesis of predetermined neck-shaft angle and assessed the effect of changes in the hip anatomy on clinical outcomes. In total, 44 patients (mean age 65.3 years (standard deviation (SD) 7); 17 male/27 female; mean body mass index 26.9 (kg/m²) (SD 3.1)) underwent a pre- and post-operative three-dimensional CT scanning of the hip. The pre- and post-operative neck-shaft angle, offset, hip centre of rotation, femoral anteversion, and stem alignment were measured. Additionally, a functional assessment and pain score were evaluated before surgery and at one year post-operatively and related to the post-operative anatomical changes. The mean pre-operative neck-shaft angle was significantly increased by 2.8° from 128° (SD 6.2; 119° to 147°) to 131° (SD 2.1; 127° to 136°) (p = 0.009). The mean pre-operative anteversion was 24.9° (SD 8; 7.9 to 39.1) and reduced to 7.4° (SD 7.3; -11.6° to 25.9°) post-operatively (p shaft angles was found with a significant decrease of the post-operative anteversion and slight increase of the neck-shaft angles, but without any impact on clinical outcome. ©2015 The British Editorial Society of Bone & Joint Surgery.

  11. Brain-like associative learning using a nanoscale non-volatile phase change synaptic device array

    Directory of Open Access Journals (Sweden)

    Sukru Burc Eryilmaz

    2014-07-01

    Full Text Available Recent advances in neuroscience together with nanoscale electronic device technology have resulted in huge interests in realizing brain-like computing hardwares using emerging nanoscale memory devices as synaptic elements. Although there has been experimental work that demonstrated the operation of nanoscale synaptic element at the single device level, network level studies have been limited to simulations. In this work, we demonstrate, using experiments, array level associative learning using phase change synaptic devices connected in a grid like configuration similar to the organization of the biological brain. Implementing Hebbian learning with phase change memory cells, the synaptic grid was able to store presented patterns and recall missing patterns in an associative brain-like fashion. We found that the system is robust to device variations, and large variations in cell resistance states can be accommodated by increasing the number of training epochs. We illustrated the tradeoff between variation tolerance of the network and the overall energy consumption, and found that energy consumption is decreased significantly for lower variation tolerance.

  12. New Drugs and Devices from 2011 – 2012 That Might Change Your Practice

    Directory of Open Access Journals (Sweden)

    Lex, Joe

    2013-11-01

    Full Text Available To be honest, I thought this would be a lost cause. Even after skipping a New Drugs and Devices essay in 2012, I figured that I would have to search long and hard to find ten new things that emergency practitioners needed to know about. Although there were no true blockbuster medications for emergency physicians, I nonetheless found ten medicines that we probably should know, along with a new device that may change the way we work up patients with palpitations, and a clever new delivery system for subcutaneous epinephrine. [West J Emerg Med. 2013;14(6:619–628.

  13. Changing Content Industry Structures: The Case of Digital Newspapers on ePaper Mobile Devices

    OpenAIRE

    L. Van Audenhove; S. Delaere; P. Ballon; M. Van Bossuyt

    2007-01-01

    The proposed paper analyses the changes in business models employed by the stakeholders in the newspaper value network, in the context of a new type of electronic reading device -the ePaper. This PDA-like device uses a new high-contrast, low-power screen technology (eInk), which holds the promise of a digital and mobile reading experience close to that of 'real' paper. The potential impact of massive digitally distributed reading content -newspapers, but also magazines, books, and all other m...

  14. Physical mechanism causing rapid changes in ultrarelativistic electron pitch angle distributions right after a shock arrival: Evaluation of an electron dropout event

    Science.gov (United States)

    Zhang, X.-J.; Li, W.; Thorne, R. M.; Angelopoulos, V.; Ma, Q.; Li, J.; Bortnik, J.; Nishimura, Y.; Chen, L.; Baker, D. N.; Reeves, G. D.; Spence, H. E.; Kletzing, C. A.; Kurth, W. S.; Hospodarsky, G. B.; Blake, J. B.; Fennell, J. F.

    2016-09-01

    Three mechanisms have been proposed to explain relativistic electron flux depletions (dropouts) in the Earth's outer radiation belt during storm times: adiabatic expansion of electron drift shells due to a decrease in magnetic field strength, magnetopause shadowing and subsequent outward radial diffusion, and precipitation into the atmosphere (driven by EMIC wave scattering). Which mechanism predominates in causing electron dropouts commonly observed in the outer radiation belt is still debatable. In the present study, we evaluate the physical mechanism that may be primarily responsible for causing the sudden change in relativistic electron pitch angle distributions during a dropout event observed by Van Allen Probes during the main phase of the 27 February 2014 storm. During this event, the phase space density of ultrarelativistic (>1 MeV) electrons was depleted by more than 1 order of magnitude over the entire radial extent of the outer radiation belt (3 pitch angle distribution under a compressed magnetic field topology based on actual solar wind conditions. Although these ultrarelativistic electrons exhibit highly anisotropic (peaked in 90°), energy-dependent pitch angle distributions, which appear to be associated with the typical EMIC wave scattering, comparison of the modeled electron distribution to electron measurements indicates that drift shell splitting is responsible for this rapid change in electron pitch angle distributions. This further indicates that magnetopause loss is the predominant cause of the electron dropout right after the shock arrival.

  15. Physical mechanism causing rapid changes in ultrarelativistic electron pitch angle distributions right after a shock arrival: Evaluation of an electron dropout event: Drift Shell Splitting on the Dayside

    International Nuclear Information System (INIS)

    Zhang, X.-J.; University of California, Los Angeles, CA; Li, W.; Boston University, MA; Thorne, R. M.

    2016-01-01

    Three mechanisms have been proposed to explain relativistic electron flux depletions (dropouts) in the Earth's outer radiation belt during storm times: adiabatic expansion of electron drift shells due to a decrease in magnetic field strength, magnetopause shadowing and subsequent outward radial diffusion, and precipitation into the atmosphere (driven by EMIC wave scattering). Which mechanism predominates in causing electron dropouts commonly observed in the outer radiation belt is still debatable. In the present study, we evaluate the physical mechanism that may be primarily responsible for causing the sudden change in relativistic electron pitch angle distributions during a dropout event observed by Van Allen Probes during the main phase of the 27 February 2014 storm. During this event, the phase space density of ultrarelativistic (>1MeV) electrons was depleted by more than 1 order of magnitude over the entire radial extent of the outer radiation belt (3 < L* < 5) in less than 6 h after the passage of an interplanetary shock. We model the electron pitch angle distribution under a compressed magnetic field topology based on actual solar wind conditions. Although these ultrarelativistic electrons exhibit highly anisotropic (peaked in 90°), energy-dependent pitch angle distributions, which appear to be associated with the typical EMIC wave scattering, comparison of the modeled electron distribution to electron measurements indicates that drift shell splitting is responsible for this rapid change in electron pitch angle distributions. This further indicates that magnetopause loss is the predominant cause of the electron dropout right after the shock arrival.

  16. Performance evaluation of a thermoelectric energy harvesting device using various phase change materials

    International Nuclear Information System (INIS)

    Elefsiniotis, A; Becker, T; Kiziroglou, M E; Wright, S W; Toh, T T; Mitcheson, P D; Yeatman, E M; Schmid, U

    2013-01-01

    This paper compares the performance of a group of organic and inorganic phase change materials for a heat storage thermoelectric energy harvesting device. The device consists of thermoelectric generators and a closed container filled with a phase change material. One side of the generators is mounted on the aircraft fuselage and the other to the thermal mass. The group of inorganic and organic phase change materials was tested across two temperature ranges. These ranges are defined as ''positive'' and ''negative'', with the former being a sweep from +35°C to −5°C and the latter being a sweep from +5°C to −35°C. The performance in terms of electrical energy output and power produced is examined in detail for each group of materials

  17. Graphene Aerogel Templated Fabrication of Phase Change Microspheres as Thermal Buffers in Microelectronic Devices.

    Science.gov (United States)

    Wang, Xuchun; Li, Guangyong; Hong, Guo; Guo, Qiang; Zhang, Xuetong

    2017-11-29

    Phase change materials, changing from solid to liquid and vice versa, are capable of storing and releasing a large amount of thermal energy during the phase change, and thus hold promise for numerous applications including thermal protection of electronic devices. Shaping these materials into microspheres for additional fascinating properties is efficient but challenging. In this regard, a novel phase change microsphere with the design for electrical-regulation and thermal storage/release properties was fabricated via the combination of monodispersed graphene aerogel microsphere (GAM) and phase change paraffin. A programmable method, i.e., coupling ink jetting-liquid marbling-supercritical drying (ILS) techniques, was demonstrated to produce monodispersed graphene aerogel microspheres (GAMs) with precise size-control. The resulting GAMs showed ultralow density, low electrical resistance, and high specific surface area with only ca. 5% diameter variation coefficient, and exhibited promising performance in smart switches. The phase change microspheres were obtained by capillary filling of phase change paraffin inside the GAMs and exhibited excellent properties, such as low electrical resistance, high latent heat, well sphericity, and thermal buffering. Assembling the phase change microsphere into the microcircuit, we found that this tiny device was quite sensitive and could respond to heat as low as 0.027 J.

  18. Effect of torsion angle on electronic transport through different anchoring groups in molecular junction

    International Nuclear Information System (INIS)

    Xia Caijuan; Fang Changfeng; Zhao Peng; Xie Shijie; Liu Desheng

    2009-01-01

    By applying nonequilibrium Green's function formalism combined with first-principles density functional theory, we investigate effect of torsion angle on electronic transport properties of 4,4 ' -biphenyl molecule connected with different anchoring groups (dithiocarboxylate and thiol group) to Au(111) electrodes. The influence of the HOMO-LUMO gaps and the spatial distributions of molecular orbitals on the quantum transport through the molecular device are discussed. Theoretical results show that the torsion angle plays important role in conducting behavior of molecular devices. By changing the torsion angle between two phenyl rings, namely changing the magnitude of the intermolecular coupling effect, a different transport behavior can be observed in these two systems.

  19. Design changes of device to investigation of alloys linear contraction and shrinkage stresses

    Directory of Open Access Journals (Sweden)

    J. Mutwil

    2009-07-01

    Full Text Available Some design changes in device elaborated by author to examination of linear contraction and shrinkage stresses progress of metals and alloys during– and after solidification have been described. The introduced changes have been focused on design of closing of shrinkage test rod mould. The introduced changes have been allowed to simplify a mounting procedure of thermocouples measuring a temperature of the shrinkage rod casting (in 6 points. Exemplary investigation results of linear contraction and shrinkage stresses development in Al-Si13.5% alloy have been presented.

  20. Appdaptivity: An Internet of Things Device-Decoupled System for Portable Applications in Changing Contexts

    Directory of Open Access Journals (Sweden)

    Cristian Martín

    2018-04-01

    Full Text Available Currently, applications in the Internet of Things (IoT are tightly coupled to the underlying physical devices. As a consequence, upon adding a device, device replacement or user’s relocation to a different physical space, application developers have to re-perform installation and configuration processes to reconfigure applications, which bears costs in time and knowledge of low-level details. In the emerging IoT field, this issue is even more challenging due to its current unpredictable growth in term of applications and connected devices. In addition, IoT applications can be personalised to each end user and can be present in different environments. As a result, IoT scenarios are very changeable, presenting a challenge for IoT applications. In this paper we present Appdaptivity, a system that enables the development of portable device-decoupled applications that can be adapted to changing contexts. Through Appdaptivity, application developers can intuitively create portable and personalised applications, disengaging from the underlying physical infrastructure. Results confirms a good scalability of the system in terms of connected users and components involved.

  1. Appdaptivity: An Internet of Things Device-Decoupled System for Portable Applications in Changing Contexts.

    Science.gov (United States)

    Martín, Cristian; Hoebeke, Jeroen; Rossey, Jen; Díaz, Manuel; Rubio, Bartolomé; Van den Abeele, Floris

    2018-04-26

    Currently, applications in the Internet of Things (IoT) are tightly coupled to the underlying physical devices. As a consequence, upon adding a device, device replacement or user’s relocation to a different physical space, application developers have to re-perform installation and configuration processes to reconfigure applications, which bears costs in time and knowledge of low-level details. In the emerging IoT field, this issue is even more challenging due to its current unpredictable growth in term of applications and connected devices. In addition, IoT applications can be personalised to each end user and can be present in different environments. As a result, IoT scenarios are very changeable, presenting a challenge for IoT applications. In this paper we present Appdaptivity, a system that enables the development of portable device-decoupled applications that can be adapted to changing contexts. Through Appdaptivity, application developers can intuitively create portable and personalised applications, disengaging from the underlying physical infrastructure. Results confirms a good scalability of the system in terms of connected users and components involved.

  2. Mixed-Integer Nonlinear Programming for Aircraft Conflict Avoidance by Sequentially Applying Velocity and Heading Angle Changes

    OpenAIRE

    Cafieri , Sonia; Omheni , Riadh

    2016-01-01

    International audience; We consider the problem of aircraft conflict avoidance in Air Traffic Management systems. Given an initial configuration of a number of aircraft sharing the same airspace, the main goal of conflict avoidance is to guarantee that a minimum safety distance between each pair of aircraft is always respected during their flights. We consider aircraft separation achieved by heading angle deviations, and propose a mixed 0-1 nonlinear optimization model, that is then combined ...

  3. Consideration of Shoulder Joint's Image with the Changed Tube Angle of the Shoulder Oblique Projection in Supine Position

    International Nuclear Information System (INIS)

    Seo, Jae Hyun; Choi, Nam Gil

    2008-01-01

    There is a standard shoulder oblique method (Grashey method) available to view the shoulder joint. This method projects AP view of the shoulder joint so that the Humerus head's subuxation or joint degeneration can be easily visualized. However, in this view, the patients, with supine or sitting or erect position, have to keep their body obliquely. Whereas, the patients who are not well or operated, usually feel very uncomfortable to keep their body in this position and hence, we need other persons' help and much efforts will be needed to get the good quality shoulder joint view. Therefore, we thought of examining a method which shows the joint well by angling the tube to Medio-Lateral direction and without keeping the patients' one side upward in supine position. For this study, total 15 subjects with no history of neurological or psychiatric illness, were recruited for examinations. They consisted of 9 males and 6 females. Statistic group analysis was performed with ANOVA test. Scores of the evaluation of the experts were 1.01±0.54 at 25 degrees, 2.50±0.50 at 30 degrees, 2.85±0.36 at 35 degrees and 2.33±0.47 at 40 degrees, respectively, and they were significant(p<0.05, Table 1). Joint space of the Humerus head and Scapula were well distinguished at 35 degrees, 30 degrees and 40 degrees with the almost same score. However, the degree of distortion at 40 degrees was more severe than that at 30 degrees. Ultimately, 30-35 degrees views were shown to yield good quality shoulder oblique images. In conclusion, this method may be very useful for the patients who are uncomfortable and for the emergency patients. In order to get similar or comparable view, the same X-tube angle is recommended to be used before and after the operation. Therefore, we hope that this new angled method seems to be efficient.

  4. An ontology-based annotation of cardiac implantable electronic devices to detect therapy changes in a national registry.

    Science.gov (United States)

    Rosier, Arnaud; Mabo, Philippe; Chauvin, Michel; Burgun, Anita

    2015-05-01

    The patient population benefitting from cardiac implantable electronic devices (CIEDs) is increasing. This study introduces a device annotation method that supports the consistent description of the functional attributes of cardiac devices and evaluates how this method can detect device changes from a CIED registry. We designed the Cardiac Device Ontology, an ontology of CIEDs and device functions. We annotated 146 cardiac devices with this ontology and used it to detect therapy changes with respect to atrioventricular pacing, cardiac resynchronization therapy, and defibrillation capability in a French national registry of patients with implants (STIDEFIX). We then analyzed a set of 6905 device replacements from the STIDEFIX registry. Ontology-based identification of therapy changes (upgraded, downgraded, or similar) was accurate (6905 cases) and performed better than straightforward analysis of the registry codes (F-measure 1.00 versus 0.75 to 0.97). This study demonstrates the feasibility and effectiveness of ontology-based functional annotation of devices in the cardiac domain. Such annotation allowed a better description and in-depth analysis of STIDEFIX. This method was useful for the automatic detection of therapy changes and may be reused for analyzing data from other device registries.

  5. Orientation-dependent changes in MR signal intensity of articular cartilage: a manifestation of the ``magic angle`` effect

    Energy Technology Data Exchange (ETDEWEB)

    Wacker, F.K.; Bolze, X.; Felsenberg, D.; Wolf, K.J. [Department of Radiology, Benjamin Franklin University Hospital, Free University Berlin, D-12200 Berlin (Germany)

    1998-06-01

    Objective: To study magnetic resonance (MR) imaging pattern of normal hyaline articular cartilage in the knee joint with regard to the contribution of the ``magic angle`` effect to the MR signal. Design. Thirty-two healthy volunteers were imaged in a standard supine position in a 1.5-T unit using spin echo and gradient echo sequences. Nine volunteers were reimaged with the knee flexed. The signal behavior of the hyaline cartilage of the femoral condyles was evaluated qualitatively and quantitatively. The extended and flexed positions of the nine volunteers were compared. Results. A superficial and a deep hyperintense layer and a hypointense middle cartilage layer were observed. Segments of increased signal intensity were visible along the condyles; a magic angle effect on signal intensity was evident in the hypointense middle layer with both gradient echo and spin echo images. Conclusion. The MR signal behavior of hyaline cartilage is influenced by the alignment of the collagen fibers within the cartilage in relation to the magnetic field. Failure to recognize this effect may lead to inaccurate diagnosis. (orig.) With 4 figs., 17 refs.

  6. Grazing incidence angle based sensing approach integrated with fiber-optic Fourier transform infrared (FO-FTIR) spectroscopy for remote and label-free detection of medical device contaminations

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, Moinuddin, E-mail: moinuddin.hassan@fda.hhs.gov; Ilev, Ilko [Optical Therapeutics and Medical Nanophotonics Laboratory, Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland 20993 (United States)

    2014-10-15

    Contamination of medical devices has become a critical and prevalent public health safety concern since medical devices are being increasingly used in clinical practices for diagnostics, therapeutics and medical implants. The development of effective sensing methods for real-time detection of pathogenic contamination is needed to prevent and reduce the spread of infections to patients and the healthcare community. In this study, a hollow-core fiber-optic Fourier transform infrared spectroscopy methodology employing a grazing incidence angle based sensing approach (FO-FTIR-GIA) was developed for detection of various biochemical contaminants on medical device surfaces. We demonstrated the sensitivity of FO-FTIR-GIA sensing approach for non-contact and label-free detection of contaminants such as lipopolysaccharide from various surface materials relevant to medical device. The proposed sensing system can detect at a minimum loading concentration of approximately 0.7 μg/cm{sup 2}. The FO-FTIR-GIA has the potential for the detection of unwanted pathogen in real time.

  7. Metasurfaces Based on Phase-Change Material as a Reconfigurable Platform for Multifunctional Devices

    Science.gov (United States)

    Raeis-Hosseini, Niloufar; Rho, Junsuk

    2017-01-01

    Integration of phase-change materials (PCMs) into electrical/optical circuits has initiated extensive innovation for applications of metamaterials (MMs) including rewritable optical data storage, metasurfaces, and optoelectronic devices. PCMs have been studied deeply due to their reversible phase transition, high endurance, switching speed, and data retention. Germanium-antimony-tellurium (GST) is a PCM that has amorphous and crystalline phases with distinct properties, is bistable and nonvolatile, and undergoes a reliable and reproducible phase transition in response to an optical or electrical stimulus; GST may therefore have applications in tunable photonic devices and optoelectronic circuits. In this progress article, we outline recent studies of GST and discuss its advantages and possible applications in reconfigurable metadevices. We also discuss outlooks for integration of GST in active nanophotonic metadevices. PMID:28878196

  8. Role of potential fluctuations in phase-change GST memory devices

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, Satish C. [Department of Physics, Indian Institute of Technology, Kanpur 208016 (India)

    2012-10-15

    The long range potential fluctuations (LRPFs) arising from the defects and heterogeneities in disordered semiconductors are important for understanding their atomic and electronic properties. Here, they are measured in Ge{sub X}Sb{sub Y}Te{sub 1-X-Y} (GST) chalcogenide glasses used in rewritable phase change memory (PCM) devices. It is found that the most commonly used composition Ge{sub 2}Sb{sub 2}Te{sub 5} has the smallest LRPF amongst its nearby compositions. This finding may be useful in the search for better PCM materials. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  9. X-ray-absorption fine structure determination of pressure-induced bond-angle changes in ReO3

    International Nuclear Information System (INIS)

    Houser, B.; Ingalls, R.

    2000-01-01

    We report here on a Marquardt-type method to fit the x-ray absorption fine structure (XAFS) of ReO 3 . We find that, when the ambient-pressure structure of ReO 3 is used as a starting point, the pressure dependence of the angle of the Re-O-Re bond in ReO 3 is fairly straightforwardly and robustly determined using FEFF curved-wave, multiple-scattering programs and is accurate to about ±1.5 degree sign or better. We present an argument that XAFS and scattering experiments fundamentally differ in what they measure in the case of nearly linear atomic bridges. Focussed multiple-scattering paths involving the Re-O-Re bridge make a contribution to the XAFS spectrum that is sensitive to the rms deviation of oxygen from the [100]-type directions. Fits to simulated spectra back up our contention that for XAFS experiments the effective position of the oxygen atom is its rms displacement whether the average displacement is zero or not. (c) 2000 The American Physical Society

  10. A Longitudinal Study on the Uses of Mobile Tablet Devices and Changes in Digital Media Literacy of Young Adults

    Science.gov (United States)

    Park, Sora; Burford, Sally

    2013-01-01

    This study examined whether gaining access to a new digital device enhanced the digital media literacy of young adults and what factors determine such change. Thirty-five young adults were given a mobile tablet device and observed for one year. Participants engaged in an online community, responding regularly to online surveys and discussion…

  11. Angle Performance on Optima XE

    International Nuclear Information System (INIS)

    David, Jonathan; Satoh, Shu

    2011-01-01

    Angle control on high energy implanters is important due to shrinking device dimensions, and sensitivity to channeling at high beam energies. On Optima XE, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through a series of narrow slits, and any angle adjustment is made by steering the beam with the corrector magnet. In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightly tilting the wafer platen during implant.Using a sensitive channeling condition, we were able to quantify the angle repeatability of Optima XE. By quantifying the sheet resistance sensitivity to both horizontal and vertical angle variation, the total angle variation was calculated as 0.04 deg. (1σ). Implants were run over a five week period, with all of the wafers selected from a single boule, in order to control for any crystal cut variation.

  12. Dynamic changes of anterior segment in patients with different stages of primary angle-closure in both eyes and normal subjects.

    Directory of Open Access Journals (Sweden)

    Jialiu Lin

    Full Text Available To compare changes in anterior segment parameters under light and dark (light-to-dark conditions among eyes with chronic primary angle-closure glaucoma (CPACG, fellow eyes with confirmed or suspect primary angle-closure (PAC or PACS, and age-matched healthy eyes.Consecutive patients with CPACG in one eye and PAC/PACS in the fellow eye, as well as age-matched healthy subjects were recruited. Anterior segment optical coherence tomography measurements were conducted under light and dark conditions, and anterior chamber, lens, and iris parameters compared. Demographic and biometric factors associated with light-to-dark change in iris area were analyzed by linear regression.Fifty-seven patients (mean age 59.6±8.9 years and 30 normal subjects matched for age (60.6±9.3 years and sex ratio were recruited. In regards to differences under light-to-dark conditions, angle opening distance at 500 μm (AOD500μm and iris area during light-to-dark transition were smaller in CPACG eyes than fellow PACS/PAC eyes and normal eyes (P<0.017. Pupil diameter change was largest in normal eyes, and larger in PACS/PAC eyes than CPACG eyes (P<0.017. There was an average reduction of 0.145 mm2 in iris area for each millimeter of pupil diameter increase in CPACG eyes, 0.161 mm2 in fellow PAC/PACS eyes, and 0.165 mm2 in normal eyes. Larger iris curvature in the dark and diagnosis of PACG were significantly associated with less light-to-dark iris area changes.Dynamic changes in iris parameters with light-to-dark transition differed significantly among CPACG eyes, fellow PAC/PACS eyes, and normal eyes. Greater iris curvature under dark conditions was correlated with reduced light-to-dark change in iris area and pupil diameter, which may contribute to disease progression.

  13. Single Nanostructure Electrochemical Devices for Studying Electronic Properties and Structural Changes in Lithiated Si Nanowires

    KAUST Repository

    McDowell, Matthew T.; Cui, Yi

    2011-01-01

    Nanostructured Si is a promising anode material for the next generation of Li-ion batteries, but few studies have focused on the electrical properties of the Li-Si alloy phase, which are important for determining power capabilities and ensuring sufficient electrical conduction in the electrode structure. Here, we demonstrate an electrochemical device framework suitable for testing the electrical properties of single Si nanowires (NWs) at different lithiation states and correlating these properties with structural changes via transmission electron microscopy (TEM). We fi nd that single Si NWs usually exhibit Ohmic I - V response in the lithiated state, with conductivities two to three orders of magnitude higher than in the delithiated state. After a number of sequential lithiation/delithiation cycles, the single NWs show similar conductivity after each lithiation step but show large variations in conductivity in the delithiated state. Finally, devices with groups of NWs in physical contact were fabricated, and structural changes in the NWs were observed after lithiation to investigate how the electrical resistance of NW junctions and the NWs themselves affect the lithiation behavior. The results suggest that electrical resistance of NW junctions can limit lithiation. Overall, this study shows the importance of investigating the electronic properties of individual components of a battery electrode (single nanostructures in this case) along with studying the nature of interactions within a collection of these component structures. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Single Nanostructure Electrochemical Devices for Studying Electronic Properties and Structural Changes in Lithiated Si Nanowires

    KAUST Repository

    McDowell, Matthew T.

    2011-07-19

    Nanostructured Si is a promising anode material for the next generation of Li-ion batteries, but few studies have focused on the electrical properties of the Li-Si alloy phase, which are important for determining power capabilities and ensuring sufficient electrical conduction in the electrode structure. Here, we demonstrate an electrochemical device framework suitable for testing the electrical properties of single Si nanowires (NWs) at different lithiation states and correlating these properties with structural changes via transmission electron microscopy (TEM). We fi nd that single Si NWs usually exhibit Ohmic I - V response in the lithiated state, with conductivities two to three orders of magnitude higher than in the delithiated state. After a number of sequential lithiation/delithiation cycles, the single NWs show similar conductivity after each lithiation step but show large variations in conductivity in the delithiated state. Finally, devices with groups of NWs in physical contact were fabricated, and structural changes in the NWs were observed after lithiation to investigate how the electrical resistance of NW junctions and the NWs themselves affect the lithiation behavior. The results suggest that electrical resistance of NW junctions can limit lithiation. Overall, this study shows the importance of investigating the electronic properties of individual components of a battery electrode (single nanostructures in this case) along with studying the nature of interactions within a collection of these component structures. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Ring magnet firing angle control

    International Nuclear Information System (INIS)

    Knott, M.J.; Lewis, L.G.; Rabe, H.H.

    1975-01-01

    A device is provided for controlling the firing angles of thyratrons (rectifiers) in a ring magnet power supply. A phase lock loop develops a smooth ac signal of frequency equal to and in phase with the frequency of the voltage wave developed by the main generator of the power supply. A counter that counts from zero to a particular number each cycle of the main generator voltage wave is synchronized with the smooth AC signal of the phase lock loop. Gates compare the number in the counter with predetermined desired firing angles for each thyratron and with coincidence the proper thyratron is fired at the predetermined firing angle

  16. Implant Strategy-Specific Changes in Symptoms in Response to Left Ventricular Assist Devices.

    Science.gov (United States)

    Lee, Christopher S; Gelow, Jill M; Chien, Christopher V; Hiatt, Shirin O; Bidwell, Julie T; Denfeld, Quin E; Grady, Kathleen L; Mudd, James O

    Although we know that the quality of life generally improves after left ventricular assist device (LVAD) implantation, we know little about how symptoms change in response to LVAD. The purpose of this study was to compare the changes in symptoms between bridge and destination therapy patients as part of a prospective cohort study. Physical (dyspnea and wake disturbances) and affective symptoms (depression and anxiety) were measured before LVAD and at 1, 3, and 6 months after LVAD. Multiphase growth modeling was used to capture the 2 major phases of change: initial improvements between preimplant and 1 month after LVAD and subsequent improvements between 1 and 6 months after LVAD. The sample included 64 bridge and 22 destination therapy patients as the preimplant strategy. Destination patients had worse preimplant dyspnea and wake disturbances, and they experienced greater initial improvements in these symptoms compared with bridge patients (all P .05). Destination patients had worse preimplant depression (P = .042) but experienced similar initial and subsequent improvements in depression in response to LVAD compared with bridge patients (both P > .05). Destination patients had similar preimplant anxiety (P = .279) but experienced less initial and greater subsequent improvements in anxiety after LVAD compared with bridge patients (both P < .05). There are many differences in the magnitude and timing of change in symptom responses to LVAD between bridge and destination therapy patients. Detailed information on changes in specific symptoms may better inform shared decision-making regarding LVAD.

  17. Small angle X-ray scattering study of thermodynamic and conformational changes in ion-containing symmetric diblock copolymers

    Energy Technology Data Exchange (ETDEWEB)

    Gunkel, Ilja [Max Planck Institute of Microstructure Physics, Halle (Germany); Institute of Physics, Martin Luther University Halle Wittenberg, Halle (Germany); Thurn-Albrecht, Thomas [Institute of Physics, Martin Luther University Halle Wittenberg, Halle (Germany)

    2010-07-01

    We present temperature-dependent SAXS measurements on two different symmetric block copolymers with added salt (lithiumtriflate, LiCF{sub 3}SO{sub 3}). For both studied systems, polystyrene-b-poly-2-vinylpyridine (PS-b-P2VP) and Polystyrene-b-Polyethyleneoxide (PS-b-PEO), the salt selectively dissolved in one block leading to large increases of the order-disorder transition temperatures (T{sub ODT}). In addition, the lamellar thickness of these ion-containing block copolymers nontrivially changed above a certain salt concentration - in PS-b-P2VP the lamellae became thicker whereas their thickness decreased in PS-b-PEO. Using basic arguments of the thermodynamics of block copolymers we were able to separate the ion-induced increase of T{sub ODT} due to a higher incompatibility between the different blocks from changes in the thickness of the lamellae at T{sub ODT} resulting from changes in the conformation of the ion-containing blocks.

  18. Compensating for Tissue Changes in an Ultrasonic Power Link for Implanted Medical Devices.

    Science.gov (United States)

    Vihvelin, Hugo; Leadbetter, Jeff; Bance, Manohar; Brown, Jeremy A; Adamson, Robert B A

    2016-04-01

    Ultrasonic power transfer using piezoelectric devices is a promising wireless power transfer technology for biomedical implants. However, for sub-dermal implants where the separation between the transmitter and receiver is on the order of several acoustic wavelengths, the ultrasonic power transfer efficiency (PTE) is highly sensitive to the distance between the transmitter and receiver. This sensitivity can cause large swings in efficiency and presents a serious limitation on battery life and overall performance. A practical ultrasonic transcutaneous energy transfer (UTET) system design must accommodate different implant depths and unpredictable acoustic changes caused by tissue growth, hydration, ambient temperature, and movement. This paper describes a method used to compensate for acoustic separation distance by varying the transmit (Tx) frequency in a UTET system. In a benchtop UTET system we experimentally show that without compensation, power transfer efficiency can range from 9% to 25% as a 5 mm porcine tissue sample is manipulated to simulate in situ implant conditions. Using an active frequency compensation method, we show that the power transfer efficiency can be kept uniformly high, ranging from 20% to 27%. The frequency compensation strategy we propose is low-power, non-invasive, and uses only transmit-side measurements, making it suitable for active implanted medical device applications.

  19. Large resistance change on magnetic tunnel junction based molecular spintronics devices

    Science.gov (United States)

    Tyagi, Pawan; Friebe, Edward

    2018-05-01

    Molecular bridges covalently bonded to two ferromagnetic electrodes can transform ferromagnetic materials and produce intriguing spin transport characteristics. This paper discusses the impact of molecule induced strong coupling on the spin transport. To study molecular coupling effect the octametallic molecular cluster (OMC) was bridged between two ferromagnetic electrodes of a magnetic tunnel junction (Ta/Co/NiFe/AlOx/NiFe/Ta) along the exposed side edges. OMCs induced strong inter-ferromagnetic electrode coupling to yield drastic changes in transport properties of the magnetic tunnel junction testbed at the room temperature. These OMCs also transformed the magnetic properties of magnetic tunnel junctions. SQUID and ferromagnetic resonance studies provided insightful data to explain transport studies on the magnetic tunnel junction based molecular spintronics devices.

  20. Determination of structural changes of dispersed clay platelets in a polymer blend during solid-state rheological property measurement by small-angle X-ray scattering

    CSIR Research Space (South Africa)

    Bandyopadhyay, J

    2011-05-01

    Full Text Available -angle X-ray scattering studies showed that the degree of anisotropy and mean orientation angles of clay platelets in blend matrix were altered significantly after frequency and temperature sweep tests....

  1. Optically reconfigurable metasurfaces and photonic devices based on phase change materials

    Science.gov (United States)

    Wang, Qian; Rogers, Edward T. F.; Gholipour, Behrad; Wang, Chih-Ming; Yuan, Guanghui; Teng, Jinghua; Zheludev, Nikolay I.

    2016-01-01

    Photonic components with adjustable parameters, such as variable-focal-length lenses or spectral filters, which can change functionality upon optical stimulation, could offer numerous useful applications. Tuning of such components is conventionally achieved by either micro- or nanomechanical actuation of their constituent parts, by stretching or by heating. Here, we report a novel approach for making reconfigurable optical components that are created with light in a non-volatile and reversible fashion. Such components are written, erased and rewritten as two-dimensional binary or greyscale patterns into a nanoscale film of phase-change material by inducing a refractive-index-changing phase transition with tailored trains of femtosecond pulses. We combine germanium-antimony-tellurium-based films with a diffraction-limited resolution optical writing process to demonstrate a variety of devices: visible-range reconfigurable bichromatic and multi-focus Fresnel zone plates, a super-oscillatory lens with subwavelength focus, a greyscale hologram, and a dielectric metamaterial with on-demand reflection and transmission resonances.

  2. Frontal Changes in the Lower Face After Clockwise Rotation of the Maxillomandibular Complex Without Perisurgical Orthodontic Treatment in Angle Class I and Skeletal Class III Women.

    Science.gov (United States)

    Lee, Sang Woo; Cho, Jeongmok; Kim, Kikap; Ahn, Seung Hyun

    2017-06-01

    Orthognathic surgery has become more popular to slenderize a wide lower face and to improve facial esthetics in Asian patients with normal occlusion. Clockwise rotation (CR) of the maxillomandibular complex (MMC) steepens the mandibular plane. This study performed a quantitative analysis on the influence of CR on slenderness of the lower face from the frontal view. This retrospective study included 36 female patients with Angle Class I occlusion and skeletal Class III pattern. The subjects underwent CR of the MMC without perioperative orthodontic treatment and change in the occlusion only for the purpose of esthetic improvement. Linear and angular variables were measured on a cephalogram and three-dimensional computed tomography (3D CT) obtained before and at least 6 months after surgery. Data were analyzed using paired t tests and Spearman correlations. Univariate regression analysis was used to predict the postoperative change according to the amount of posterior impaction. The mean posterior impaction was 3.81 mm. All mandibular plane angle (MPA) measurements were increased (ranged from 5.69° to 13.12°, p lower face becomes narrower and more slender as the MMC rotates in a clockwise direction. Orthognathic surgery with CR has the advantage of increasing the MPAs and obtaining natural soft tissue contouring while minimizing the amount of bone resection. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266c .

  3. Influence of Different Diffuser Angle on Sedan's Aerodynamic Characteristics

    Science.gov (United States)

    Hu, Xingjun; Zhang, Rui; Ye, Jian; Yan, Xu; Zhao, Zhiming

    The aerodynamic characteristics have a great influence on the fuel economics and the steering stability of a high speed vehicle. The underbody rear diffuser is one of important aerodynamic add-on devices. The parameters of the diffuser, including the diffuser angle, the number and the shape of separators, the shape of the end plate and etc, will affect the underbody flow and the wake. Here, just the influence of the diffuser angle was investigated without separator and the end plate. The method of Computational Fluid Dynamics was adopted to study the aerodynamic characteristics of a simplified sedan with a different diffuser angle respectively. The diffuser angle was set to 0°, 3°, 6°, 9.8° and 12° respectively. The diffuser angle of the original model is 9.8°. The conclusions were drawn that when the diffuser angle increases, the underbody flow and especially the wake change greatly and the pressure change correspondingly; as a result, the total aerodynamic drag coefficients of car first decrease and then increases, while the total aerodynamic lift coefficients decrease.

  4. Constructal design of phase change material enclosures used for cooling electronic devices

    International Nuclear Information System (INIS)

    Kalbasi, Rasool; Salimpour, Mohammad Reza

    2015-01-01

    Recent developments in cooling methods for portable electronic devices have heightened the need for using the large latent heat capacity of phase change materials (PCM). The aim of the present study is to evaluate the thermal characteristics of a PCM-based heat sink with high conductive materials. The solution is acquired as a procession of optimization stages which starts with the elemental area and proceeds toward the first assembly. Every optimization stage is the result of maximizing the safe operation time without allowing the electronics to reach the critical temperature. Primarily, the degrees of freedom and constrains were defined and then by changing the geometrical parameters, the target function which is the maximization of operation time, was optimized. Results show that the melting process in rectangular enclosures with vertical fins attached to the heated bottom surface can be affected by the contact surface between the fin and PCM and the convection of the melted PCM. For a rectangular enclosure with a constant area, it is better to use wider enclosure than the square and thin one. Also results indicate that the ratio of the vertical fin thickness to the horizontal one does not have a considerable effect on performance. By increasing the number of enclosures, the contact surface is raised, but the performance is not necessarily improved. - Highlights: • Thermal characteristics of a finned PCM-based heat sink are studied. • Constructal theory was used to optimize the PCM enclosures. • By increasing the number of enclosures, the performance is not necessarily improved

  5. How Technology and mobile devices are changing the way we shop

    Directory of Open Access Journals (Sweden)

    David Roman Coy

    2013-02-01

    Full Text Available Los dispositivos móviles son una realidad en las relaciones entre consumidores y empresas. El artículo profundiza en las utilidades de los dispositivos móviles y qué significan en la manera de entender la comercialización de producto y la interacción entre clientes y organizaciones. Estos dispositivos de última generación cambian los comportamientos de compra de los consumidores y las empresas pueden aprovechar este nuevo canal, o por lo menos comprender su funcionamiento, para no quedarse rezagados en sus relaciones con sus clientes actuales o potenciales. Geolocalización, un nuevo concepto ampliado de socialización, nuevas oportunidades de personalización, los códigos QR, los pagos a través del móvil, el m-commerce, entre otras, suponen un puente entre la realidad online y la offline que modifican los comportamientos de compra y relación de forma radical y que hay que tenerlos en cuenta. Como la tecnología y los dispositivos móviles estan cambiando la forma en que compramos  Abstract Mobile devices are a reality in the relationships between consumers and companies. The article goes deep into the uses of mobile devices and what do they mean in the way of understanding the product marketing and interaction between clients and organizations. These devices of last generation change consumer buying behaviors and the companies can take advantage of this new channel, or at least to understand its functioning, to not stay behind in its relations with its current or potential customers. Geolocation, a new extended concept of socialization, new opportunities for customization, QR codes, payments via mobile, m-commerce, among others, represent a bridge between reality online and offline purchase and relationship behaviours that modify radically and that must be taken into account. Keywords: Mobile Marketing; Retailing; Geolocation; social media; customization; QR codes; m-payments; m-commerce

  6. Clinical features and changes in epidemiology of infective endocarditis on pacemaker devices over a 27-year period (1987-2013).

    Science.gov (United States)

    Carrasco, Francisco; Anguita, Manuel; Ruiz, Martín; Castillo, Juan Carlos; Delgado, Mónica; Mesa, Dolores; Romo, Elias; Pan, Manuel; Suárez de Lezo, Jose

    2016-06-01

    Use of cardiac pacing devices has grown in recent years. Our aim was to evaluate changes in epidemiology and clinical features of infective endocarditis (IE) involving pacemaker devices in a large series of IE over the last 27 years (1987-2013). From 1987 to December 2013, 413 consecutive IE cases were diagnosed in our hospital. During this period, 7424 pacemaker devices were implanted (6917 pacemakers, 239 implantable cardiac defibrillators, 158 resynchronization devices, and 110 resynchronization/defibrillator devices). All consecutive cases of IE on pacemaker devices were included and analysed. Infective endocarditis on pacemaker devices represented 6.1% of all endocarditis cases (25 patients), affecting 3.6/1000 of all implanted pacemakers. Its proportion increased from 1.25% of all endocarditis in 1987-1993 to 4.08% in 1994-2000, 7.69% in 2001-2007 and 9.32% in 2008-2013 (P pacemaker implants in the period of 1987-1993 to 2.5/1000 in 1994-2000, 3.3/1000 in 2001-2007 and 4.5/1000 implanted devices in 2008-2013 (P pacemaker devices has shown an increasing incidence during the past decades, representing almost 10% of all IE in the last 6 years. This is a severe disease, with a high rate of severe complications and requiring removal of device in most cases. In spite of therapy, early mortality is high. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  7. Change of Femoral Anteversion Angle in Children With Intoeing Gait Measured by Three-Dimensional Computed Tomography Reconstruction: One-Year Follow-Up Study.

    Science.gov (United States)

    Kong, Minsik; Jo, Hongsik; Lee, Chang Han; Chun, Se-Woong; Yoon, Chulho; Shin, Heesuk

    2018-02-01

    To evaluate femoral anteversion angle (FAA) change in children with intoeing gait depending on age, gender, and initial FAA using three-dimensional computed tomography (3D-CT). The 3D-CT data acquired between 2006 and 2016 were retrospectively reviewed. Children 4 to 10 years of age with symptomatic intoeing gait with follow-up interval of at least 1 year without active treatment were enrolled. Subjects were divided into three groups based on age: group 1 (≥4 and FAAs were measured using 3D-CT. Mean changes in FAAs were calculated and compared. A total of 200 lower limbs of 100 children (48 males and 52 females, mean age of 6.1±1.6 years) were included. The mean follow-up period was 18.0±5.4 months. Average initial and follow-up FAA in children with intoeing gait was 31.1°±7.8° and 28.9°±8.2°, respectively. The initial FAA of group 1 was largest (33.5°±7.7°). Follow-up FAA of group 1 was significantly reduced to 28.7°±9.2° (p=0.000). FAA changes in groups 1, 2, and 3 were -6.5°±5.8°, -6.4°±5.1°, and -5.3°±4.0°, respectively. These changes of FAA were not significantly (p=0.355) different among the three age groups. However, FAA changes were higher (p=0.012) in females than those in males. In addition, FAA changes showed difference depending on initial FAA. When initial FAA was smaller than 30°, mean FAA change was -5.6°±4.9°. When initial FAA was more than 30°, mean FAA change was -6.8°±5.4° (p=0.019). FAA initial in children with intoeing gait was the greatest in age group 1 (4-6 years). This group also showed significant FAA decrease at follow-up. FAA changes were greater when the child was a female, younger, and had greater initial FAA.

  8. Control of the sidewall angle of an absorber stack using the Faraday cage system for the change of pattern printability in EUVL

    Science.gov (United States)

    Jang, Il-Yong; Huh, Sung-Min; Moon, Seong-Yong; Woo, Sang-Gyun; Lee, Jin-Kwan; Moon, Sang Heup; Cho, HanKu

    2008-10-01

    A patterned TaN substrate, which is candidate for a mask absorber in extreme ultra-violet lithography (EUVL), was etched to have inclined sidewalls by using a Faraday cage system under the condition of a 2-step process that allowed the high etch selectivity of TaN over the resist. The sidewall angle (SWA) of the patterned substrate, which was in the shape of a parallelogram after etching, could be controlled by changing the slope of a substrate holder that was placed in the Faraday cage. The performance of an EUV mask, which contained the TaN absorber of an oblique pattern over the molybdenum/silicon multi-layer, was simulated for different cases of SWA. The results indicated that the optical properties, such as the critical dimension (CD), an offset in the CD bias between horizontal and vertical patterns (H-V bias), and a shift in the image position on the wafer, could be controlled by changing the SWA of the absorber stack. The simulation result showed that the effect of the SWA on the optical properties became more significant at larger thicknesses of the absorber and smaller sizes of the target CD. Nevertheless, the contrast of the aerial images was not significantly decreased because the shadow effect caused by either sidewall of the patterned substrate cancelled with each other.

  9. Angle closure glaucoma in congenital ectropion uvea

    Directory of Open Access Journals (Sweden)

    Grace M. Wang

    2018-06-01

    Full Text Available Purpose: Congenital ectropion uvea is a rare anomaly, which is associated with open, but dysplastic iridocorneal angles that cause childhood glaucoma. Herein, we present 3 cases of angle-closure glaucoma in children with congenital ectropion uvea. Observations: Three children were initially diagnosed with unilateral glaucoma secondary to congenital ectropion uvea at 7, 8 and 13 years of age. The three cases showed 360° of ectropion uvea and iris stromal atrophy in the affected eye. In one case, we have photographic documentation of progression to complete angle closure, which necessitated placement of a glaucoma drainage device 3 years after combined trabeculotomy and trabeculectomy. The 2 other cases, which presented as complete angle closure, also underwent glaucoma drainage device implantation. All three cases had early glaucoma drainage device encapsulation (within 4 months and required additional surgery (cycloablation or trabeculectomy. Conclusions and importance: Congenital ectropion uvea can be associated with angle-closure glaucoma, and placement of glaucoma drainage devices in all 3 of our cases showed early failure due to plate encapsulation. Glaucoma in congenital ectropion uvea requires attention to angle configuration and often requires multiple surgeries to obtain intraocular pressure control. Keywords: Congenital ectropion uvea, Juvenile glaucoma, Angle-closure glaucoma, Glaucoma drainage device

  10. Angle-resolved diffraction grating biosensor based on porous silicon

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Changwu; Li, Peng [School of Physical Science and Technology, Xinjiang University, Urumqi 830046 (China); Jia, Zhenhong, E-mail: jzhh@xju.edu.cn; Liu, Yajun; Mo, Jiaqing; Lv, Xiaoyi [College of Information Science and Engineering, Xinjiang University, Urumqi 830046 (China)

    2016-03-07

    In this study, an optical biosensor based on a porous silicon composite structure was fabricated using a simple method. This structure consists of a thin, porous silicon surface diffraction grating and a one-dimensional porous silicon photonic crystal. An angle-resolved diffraction efficiency spectrum was obtained by measuring the diffraction efficiency at a range of incident angles. The angle-resolved diffraction efficiency of the 2nd and 3rd orders was studied experimentally and theoretically. The device was sensitive to the change of refractive index in the presence of a biomolecule indicated by the shift of the diffraction efficiency spectrum. The sensitivity of this sensor was investigated through use of an 8 base pair antifreeze protein DNA hybridization. The shifts of the angle-resolved diffraction efficiency spectrum showed a relationship with the change of the refractive index, and the detection limit of the biosensor reached 41.7 nM. This optical device is highly sensitive, inexpensive, and simple to fabricate. Using shifts in diffraction efficiency spectrum to detect biological molecules has not yet been explored, so this study establishes a foundation for future work.

  11. Reducing domestic heating demand: Managing the impact of behavior-changing feedback devices via marketing.

    Science.gov (United States)

    Jensen, Thorben; Chappin, Émile J L

    2017-07-15

    Feedback devices can be used to inform households about their energy-consumption behavior. This may persuade them to practice energy conservation. The use of feedback devices can also-via word of mouth-spread among households and thereby support the spread of the incentivized behavior, e.g. energy-efficient heating behavior. This study investigates how to manage the impact of these environmental innovations via marketing. Marketing activities can support the diffusion of devices. This study aims to identify the most effective strategies of marketing feedback devices. We did this by adapting an agent-based model to simulate the roll-out of a novel feedback technology and heating behavior within households in a virtual city. The most promising marketing strategies were simulated and their impacts were analyzed. We found it particularly effective to lend out feedback devices to consumers, followed by leveraging the social influence of well-connected individuals, and giving away the first few feedback devices for free. Making households aware of the possibility of purchasing feedback devices was found to be least effective. However, making households aware proved to be most cost-efficient. This study shows that actively managing the roll-out of feedback devices can increase their impacts on energy-conservation both effectively and cost-efficiently. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Nanometer-scale temperature imaging for independent observation of Joule and Peltier effects in phase change memory devices.

    Science.gov (United States)

    Grosse, Kyle L; Pop, Eric; King, William P

    2014-09-01

    This paper reports a technique for independent observation of nanometer-scale Joule heating and thermoelectric effects, using atomic force microscopy (AFM) based measurements of nanometer-scale temperature fields. When electrical current flows through nanoscale devices and contacts the temperature distribution is governed by both Joule and thermoelectric effects. When the device is driven by an electrical current that is both periodic and bipolar, the temperature rise due to the Joule effect is at a different harmonic than the temperature rise due to the Peltier effect. An AFM tip scanning over the device can simultaneously measure all of the relevant harmonic responses, such that the Joule effect and the Peltier effect can be independently measured. Here we demonstrate the efficacy of the technique by measuring Joule and Peltier effects in phase change memory devices. By comparing the observed temperature responses of these working devices, we measure the device thermopower, which is in the range of 30 ± 3 to 250 ± 10 μV K(-1). This technique could facilitate improved measurements of thermoelectric phenomena and properties at the nanometer-scale.

  13. Nanometer-scale temperature imaging for independent observation of Joule and Peltier effects in phase change memory devices

    Energy Technology Data Exchange (ETDEWEB)

    Grosse, Kyle L. [Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801 (United States); Pop, Eric [Department of Electrical Engineering, Stanford University, Stanford, California 94305 (United States); King, William P., E-mail: wpk@illinois.edu [Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801 (United States); Departments of Electrical and Computer Engineering and Materials Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801 (United States)

    2014-09-15

    This paper reports a technique for independent observation of nanometer-scale Joule heating and thermoelectric effects, using atomic force microscopy (AFM) based measurements of nanometer-scale temperature fields. When electrical current flows through nanoscale devices and contacts the temperature distribution is governed by both Joule and thermoelectric effects. When the device is driven by an electrical current that is both periodic and bipolar, the temperature rise due to the Joule effect is at a different harmonic than the temperature rise due to the Peltier effect. An AFM tip scanning over the device can simultaneously measure all of the relevant harmonic responses, such that the Joule effect and the Peltier effect can be independently measured. Here we demonstrate the efficacy of the technique by measuring Joule and Peltier effects in phase change memory devices. By comparing the observed temperature responses of these working devices, we measure the device thermopower, which is in the range of 30 ± 3 to 250 ± 10 μV K{sup −1}. This technique could facilitate improved measurements of thermoelectric phenomena and properties at the nanometer-scale.

  14. Structural and phase transition changes of sodium dodecyl sulfate micellar solution in alcohols probed by small-angle neutron scattering (SANS)

    Energy Technology Data Exchange (ETDEWEB)

    Putra, Edy Giri Rachman [Neutron Scattering Laboratory, National Nuclear Energy Agency of Indonesia (BATAN), Gedung 40 BATAN, Kawasan Puspiptek Serpong, Tangerang 15314 (Indonesia); Patriati, Arum [Neutron Scattering Laboratory, National Nuclear Energy Agency of Indonesia (BATAN), Gedung 40 BATAN, Kawasan Puspiptek Serpong, Tangerang 15314 (Indonesia); Department of Chemistry, Faculty of Mathematics and Natural Sciences, University of Gadjah Mada, Bulaksumur, Yogyakarta 55281, Indonesia giri@batan.go.id (Indonesia)

    2015-04-16

    Small-angle neutron scattering (SANS) measurements on 0.3M sodium dodecyl sulfate (SDS) micellar solutions have been performed in the presence of n-alcohols, from ethanol to decanol at different alcohol concentrations, 2–10 wt%. The ellipsoid micellar structure which occurred in the 0.3M SDS in aqueous solution with the size range of 30–50 Å has different behavior at various hydrocarbon chain length and concentration of alcohols. At low concentration and short chain-length of alcohols, such as ethanol, propanol, and butanol, the size of micelles reduced and had a spherical-like structure. The opposite effect occurred as medium to long chain alcohols, such as hexanol, octanol and decanol was added into the 0.3M SDS micellar solutions. The micelles structure changed to be more elongated in major axis and then crossed the critical phase transition from micellar solution into liquid crystal phase as lamellar structure emerged by further addition of alcohols. The inter-lamellar distances were also depending on the hydrocarbon chain length and concentration of alcohols. In the meantime, the persistent micellar structures occurred in addition of medium chain of n-alcohol, pentanol at all concentrations.

  15. Structural and phase transition changes of sodium dodecyl sulfate micellar solution in alcohols probed by small-angle neutron scattering (SANS)

    International Nuclear Information System (INIS)

    Putra, Edy Giri Rachman; Patriati, Arum

    2015-01-01

    Small-angle neutron scattering (SANS) measurements on 0.3M sodium dodecyl sulfate (SDS) micellar solutions have been performed in the presence of n-alcohols, from ethanol to decanol at different alcohol concentrations, 2–10 wt%. The ellipsoid micellar structure which occurred in the 0.3M SDS in aqueous solution with the size range of 30–50 Å has different behavior at various hydrocarbon chain length and concentration of alcohols. At low concentration and short chain-length of alcohols, such as ethanol, propanol, and butanol, the size of micelles reduced and had a spherical-like structure. The opposite effect occurred as medium to long chain alcohols, such as hexanol, octanol and decanol was added into the 0.3M SDS micellar solutions. The micelles structure changed to be more elongated in major axis and then crossed the critical phase transition from micellar solution into liquid crystal phase as lamellar structure emerged by further addition of alcohols. The inter-lamellar distances were also depending on the hydrocarbon chain length and concentration of alcohols. In the meantime, the persistent micellar structures occurred in addition of medium chain of n-alcohol, pentanol at all concentrations

  16. Angle imaging: Advances and challenges

    Science.gov (United States)

    Quek, Desmond T L; Nongpiur, Monisha E; Perera, Shamira A; Aung, Tin

    2011-01-01

    Primary angle closure glaucoma (PACG) is a major form of glaucoma in large populous countries in East and South Asia. The high visual morbidity from PACG is related to the destructive nature of the asymptomatic form of the disease. Early detection of anatomically narrow angles is important and the subsequent prevention of visual loss from PACG depends on an accurate assessment of the anterior chamber angle (ACA). This review paper discusses the advantages and limitations of newer ACA imaging technologies, namely ultrasound biomicroscopy, Scheimpflug photography, anterior segment optical coherence tomography and EyeCam, highlighting the current clinical evidence comparing these devices with each other and with clinical dynamic indentation gonioscopy, the current reference standard. PMID:21150037

  17. Glaucoma, Open-Angle

    Science.gov (United States)

    ... Home » Statistics and Data » Glaucoma, Open-angle Listen Glaucoma, Open-angle Open-angle Glaucoma Defined In open-angle glaucoma, the fluid passes ... 2010 2010 U.S. Age-Specific Prevalence Rates for Glaucoma by Age and Race/Ethnicity The prevalence of ...

  18. Evolution and change of He bubbles in He-containing Ti films upon thermal treatment studied by small-angle X-ray scattering and transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Guangai [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900 (China); College of Nuclear Science and Technology, University of Science and Technology of China, Hefei, 230029 (China); Wu, Erdong, E-mail: ewu@imr.ac.cn [National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016 (China); Huang, Chaoqiang [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900 (China); College of Nuclear Science and Technology, University of Science and Technology of China, Hefei, 230029 (China); Cheng, Chun [National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016 (China); Yan, Guanyun [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900 (China); Wang, Xiaolin [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900 (China); College of Nuclear Science and Technology, University of Science and Technology of China, Hefei, 230029 (China); Liu, Shi [National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016 (China); Tian, Qiang; Chen, Bo [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900 (China); Wu, Zhonghua [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Liu, Yi; Wang, Jie [Institute of Shanghai Apply Physics, Chinese Academy of Sciences, Shanghai 201800 (China)

    2014-05-02

    Evolution and change of He bubbles in magnetron sputtering prepared He-containing Ti films under thermal treatment are studied by small-angle X-ray scattering (SAXS), transmission electron microscopy (TEM) and X-ray diffraction. Incorporation of He introduces a large number of He-vacancy clusters and some voids in the films, and significantly increases SAXS intensity and causes anisotropic scattering. The change of He induced defects during annealing is affected by thermal diffusion and migration of trapped He to the surface and between interfaces of He induced defects within the films. Annealing at 200 and 400 °C reduces intensity and anisotropy of SAXS, in accord with observed shrinking and disappearance of the voids. The simultaneous growth of non-uniformly distributed He bubbles to the sizes of 1–2 nm and a population level of 10{sup 5}/μm{sup 3} are detected in the temperature range. The changes are explained by migration and coalescence mechanisms, which requires low apparent activation energy. Inconsistence between TEM and SAXS observations is noted and attributed to thinning induced internal stress relaxation of TEM specimen. Remarkable enlargement of He bubbles, associated with increased SAXS intensity and fractal dimension, is observed after 600 °C annealing, indicating involvement of Ostwald Ripening (OR) mechanism. The OR process dominates at 800 °C, where the high temperature provides activation energy for accelerated He dissociation from small bubbles into larger ones, and generating textured microstructure and agglomerated bubble clusters. The inhomogeneous bubble size distribution observed at this temperature covers a broad range of about 10–50 nm and possessing a population density level of 10{sup 3}/μm{sup 3}. - Highlights: • Change of He bubbles in thermally treated Ti–He films is studied by SAXS and TEM. • SAXS reveals size distribution and fractional population of He bubbles in films. • He-vacancy clusters in Ti–He film

  19. In situ microfluidic dialysis for biological small-angle X-ray scattering

    DEFF Research Database (Denmark)

    Skou, Magda; Skou, Soren; Jensen, Thomas Glasdam

    2014-01-01

    Owing to the demand for low sample consumption and automated sample changing capabilities at synchrotron small-angle X-ray (solution) scattering (SAXS) beamlines, X-ray microfluidics is receiving continuously increasing attention. Here, a remote-controlled microfluidic device is presented for sim...... in incidental sample purification. Hence, this versatile microfluidic device enables investigation of experimentally induced structural changes under dynamically controllable sample conditions. (C) 2014 International Union of Crystallography......Owing to the demand for low sample consumption and automated sample changing capabilities at synchrotron small-angle X-ray (solution) scattering (SAXS) beamlines, X-ray microfluidics is receiving continuously increasing attention. Here, a remote-controlled microfluidic device is presented...

  20. A reference device for evaluating the thermal behavior of installed multilayered wall containing a phase change material

    International Nuclear Information System (INIS)

    Pagliolico, S.L.; Sassi, G.; Cascone, Y.; Bongiovanni, R.M.

    2015-01-01

    Highlights: • Thermal analysis of installed wallboards embedding phase change material layer. • Simple devices and real conditions for thermal analysis toward a standardization. • Scanning calorimetric measurements as initial condition for data regression. • Bias correction of calorimetric measurements data by installation factors. • Practical approach to identify a reliable thermal curve for capacitive wallboards. - Abstract: Thermal inertia of lightweight building envelopes can be improved including phase change materials in multilayered wallboards. The thermal modeling of buildings for design purposes needs a robust description of the thermal properties of installed phase change materials. A standard method would improve the thermal characterization of commercial products. The aim of the study is to develop a simple methodology to obtain reliable thermal data for phase change materials integrated in multilayered wallboards. The methodology modifies differential scanning calorimetry measurements on phase change material by installation factors to obtain the apparent specific heat vs. temperature for the wallboard layer embedding phase change material. Simple cubic cells were realized as reference devices to simulate a confined environment. A dynamic model of heat transfer was developed to simulate the thermal behavior of devices. Installation factors were calculated by regression of the monitored temperatures inside and outside the devices operating under real environmental conditions. The apparent specific heat of phase change material, measured by differential scanning calorimetry at different rates, resulted in a spread of curves vs. temperature. Mean curves were used as initial condition for regression. The mean calculation method did not significantly affect the installed resulted curve. A unique curve of apparent specific heat vs. temperature best fit data measured over a wide range of experimental devices and conditions. Good regression

  1. Mobile Device Trends in Orthopedic Surgery: Rapid Change and Future Implications.

    Science.gov (United States)

    Andrawis, John P; Muzykewicz, David A; Franko, Orrin I

    2016-01-01

    Mobile devices are increasingly becoming integral communication and clinical tools. Monitoring the prevalence and utilization characteristics of surgeons and trainees is critical to understanding how these new technologies can be best used in practice. The authors conducted a prospective Internet-based survey over 7 time points from August 2010 to August 2014 at all nationwide American Council for Graduate Medical Education-accredited orthopedic programs. The survey questionnaire was designed to evaluate the use of devices and mobile applications (apps) among trainees and physicians in the clinical setting. Results were analyzed and summarized for orthopedic surgeons and trainees. During the 48-month period, there were 7 time points with 467, 622, 329, 223, 237, 111, and 134 responses. Mobile device use in the clinical setting increased across all fields and levels of training during the study period. Orthopedic trainees increased their use of Smartphone apps in the clinical setting from 60% to 84%, whereas attending use increased from 41% to 61%. During this time frame, use of Apple/Android platforms increased from 45%/13% to 85%/15%, respectively. At all time points, 70% of orthopedic surgeons believed their institution/hospital should support mobile device use. As measured over a 48-month period, mobile devices have become an ubiquitous tool in the clinical setting among orthopedic surgeons and trainees. The authors expect these trends to continue and encourage providers and trainees to be aware of the limitations and risks inherent with new technology. Copyright 2016, SLACK Incorporated.

  2. Design considerations for a backlight with switchable viewing angles

    Science.gov (United States)

    Fujieda, Ichiro; Takagi, Yoshihiko; Rahadian, Fanny

    2006-08-01

    Small-sized liquid crystal displays are widely used for mobile applications such as cell phones. Electronic control of a viewing angle range is desired in order to maintain privacy for viewing in public as well as to provide wide viewing angles for solitary viewing. Conventionally, a polymer-dispersed liquid crystal (PDLC) panel is inserted between a backlight and a liquid crystal panel. The PDLC layer either transmits or scatters the light from the backlight, thus providing an electronic control of viewing angles. However, such a display system is obviously thick and expensive. Here, we propose to place an electronically-controlled, light-deflecting device between an LED and a light-guide of a backlight. For example, a liquid crystal lens is investigated for other applications and its focal length is controlled electronically. A liquid crystal phase grating either transmits or diffracts an incoming light depending on whether or not a periodic phase distribution is formed inside its liquid crystal layer. A bias applied to such a device will control the angular distribution of the light propagating inside a light-guide. Output couplers built in the light-guide extract the propagating light to outside. They can be V-shaped grooves, pyramids, or any other structures that can refract, reflect or diffract light. When any of such interactions occur, the output couplers translate the changes in the propagation angles into the angular distribution of the output light. Hence the viewing-angle characteristic can be switched. The designs of the output couplers and the LC devices are important for such a backlight system.

  3. Solar panel foundation device

    Energy Technology Data Exchange (ETDEWEB)

    Hawley, W.W.

    1983-03-29

    A transportable solar panel foundation device which has a bottom member, at least one upstanding side member, and an essentially open top. The side members are angled to permit nesting of a plurality of the foundation devices, and reinforcement pads are carried by the foundation device to support legs for one or more solar panels.

  4. Method for determining the wedge angle from the daily measurements made with the measurement enabled devices DC6; Metodo para la determinacion del angulo de cuna a partir de las medidas diarias realizadas con el dispositio de medida QC6

    Energy Technology Data Exchange (ETDEWEB)

    Marques Fraguela, E.; Suero Rodrigo, M. A.

    2011-07-01

    The aim of this paper is to present a method for determining the angle of the wedges virtual electron linear accelerator (ALE) Siemens Primus, from the daily measurements made with the measurement system PTW-QC6Plus and found to be sufficiently sensitive to determine variations of {+-} 1 of this parameter. In addition, we study the behavior statistically CUFLE angle over a year.

  5. Evaluation of cartilage surface injuries using 3D-double echo steady state (3D-DESS): Effect of changing flip angle from 40 deg to 90 deg

    International Nuclear Information System (INIS)

    Moriya, Susumu; Yokobayashi, Tsuneo; Ishikawa, Mitsunori; Miki, Yukio; Kanagaki, Mitsunori; Yamamoto, Akira; Okudaira, Shuzo; Nakamura, Shinichiro

    2011-01-01

    Background. In magnetic resonance imaging (MRI) with 3D-double-echo steady-state (3D-DESS) sequences, the cartilage-synovial fluid contrast is reported to be better with a flip angle of 90 deg than with the conventional flip angle of 40 deg, and the detection rate of knee cartilage injury may be improved. Purpose. To compare the diagnostic performance and certainty of diagnosis with 3D-DESS images made using two flip angle settings, 40 deg and 90 deg, for knee cartilage surface lesions of Grade 2 or above confirmed by arthroscopy. Material and Methods. Images were obtained with 3D-DESS flip angles of 40 deg and 90 deg at 1.0T in 13 consecutive patients (2 men, 11 women, age range 18-68 years) evaluated for superficial cartilage injury by arthroscopy. Two radiologists classified the presence or absence of cartilage damage of ≥Grade 2 as 'positive (p)' or 'negative (n)', respectively. The rate of agreement with arthroscopic diagnosis was then examined, and the diagnostic performance compared. Diagnostic confidence was assessed scoring the presence or absence of cartilage damage into three categories: 3 = can diagnose with absolute confidence; 2 = can diagnose with a level of certainty as probably present or probably absent; and 1 = cannot make a diagnosis. Results. In a comparison of the rate of agreement between diagnosis by 3D-DESS images and arthroscopy, the rate of agreement was significantly higher and diagnostic performance was better in 90 deg images for the medial femoral condyle only. Diagnostic confidence was significantly better with 90 deg flip angle images than with 40 deg flip angle images for all six cartilage surfaces. Conclusion. In evaluating knee cartilage surface lesions with 3D-DESS sequences, a flip angle setting of 90 deg is more effective than the conventional setting of 40 deg

  6. Evaluation of cartilage surface injuries using 3D-double echo steady state (3D-DESS): Effect of changing flip angle from 40 deg to 90 deg

    Energy Technology Data Exchange (ETDEWEB)

    Moriya, Susumu; Yokobayashi, Tsuneo; Ishikawa, Mitsunori (Ishikawa Clinic, Kyoto (Japan)), email: smoyari@yahoo.co.jp; Miki, Yukio (Dept. of Radiology, Osaka City Univ. Graduate School of Medicine, Osaka (Japan)); Kanagaki, Mitsunori; Yamamoto, Akira (Dept. of Diagnostic Imaging and Nuclear Medicine, Kyoto Univ., Kyoto (Japan)); Okudaira, Shuzo (Dept. of Orthopaedics, Kyoto Police Hospital, Kyoto (Japan)); Nakamura, Shinichiro (Center for Musculoskeletal Research, Univ. of Tennessee, Knoxville, TN (United States))

    2011-12-15

    Background. In magnetic resonance imaging (MRI) with 3D-double-echo steady-state (3D-DESS) sequences, the cartilage-synovial fluid contrast is reported to be better with a flip angle of 90 deg than with the conventional flip angle of 40 deg, and the detection rate of knee cartilage injury may be improved. Purpose. To compare the diagnostic performance and certainty of diagnosis with 3D-DESS images made using two flip angle settings, 40 deg and 90 deg, for knee cartilage surface lesions of Grade 2 or above confirmed by arthroscopy. Material and Methods. Images were obtained with 3D-DESS flip angles of 40 deg and 90 deg at 1.0T in 13 consecutive patients (2 men, 11 women, age range 18-68 years) evaluated for superficial cartilage injury by arthroscopy. Two radiologists classified the presence or absence of cartilage damage of >=Grade 2 as 'positive (p)' or 'negative (n)', respectively. The rate of agreement with arthroscopic diagnosis was then examined, and the diagnostic performance compared. Diagnostic confidence was assessed scoring the presence or absence of cartilage damage into three categories: 3 = can diagnose with absolute confidence; 2 = can diagnose with a level of certainty as probably present or probably absent; and 1 = cannot make a diagnosis. Results. In a comparison of the rate of agreement between diagnosis by 3D-DESS images and arthroscopy, the rate of agreement was significantly higher and diagnostic performance was better in 90 deg images for the medial femoral condyle only. Diagnostic confidence was significantly better with 90 deg flip angle images than with 40 deg flip angle images for all six cartilage surfaces. Conclusion. In evaluating knee cartilage surface lesions with 3D-DESS sequences, a flip angle setting of 90 deg is more effective than the conventional setting of 40 deg

  7. Synthesis of functional nanomaterials via colloidal mask templating and glancing angle deposition (GLAD)”

    DEFF Research Database (Denmark)

    Dolatshahi-Pirouz, Alireza; Jensen, Thomas Bo; Vorup-Jensen, Thomas

    2010-01-01

    We present a simple method for the fabrication of separated brush-like networks with both improved optical and biological properties. The brush networks were fabricated by combing the glancing angle deposition (GLAD) technique with colloidal mask templating. By changing the deposition angle durin...... of multifunctional nanomaterials which could have potential impact on devices where both controlled optical properties and cell surface interactions are needed (for instance controlled cell adhesion on optical biosensor materials).......We present a simple method for the fabrication of separated brush-like networks with both improved optical and biological properties. The brush networks were fabricated by combing the glancing angle deposition (GLAD) technique with colloidal mask templating. By changing the deposition angle during...

  8. A Designer Fluid for Aluminum Phase Change Devices, Vol. 1 of 3: General Inorganic Aqueous Solution (IAS) Chemistry

    Science.gov (United States)

    2016-11-17

    out in wicked phase change heat transfer devices. Wen [18] used nanoparticle suspensions to successfully increase the boiling heat transfer...Aqueous Solution of an Anionic Surfactant,” Journal of Heat Transfer 122, No. 4: 708. [18] Wen , D. and Ding, Y., 2005, “Experimental Investigation...Li, Y., 1974, “Diffusion of Ions in Sea Water and in Deep -Sea Sediments,” Geochimica et Cosmochimica Acta, Vol. 88, pp. 703-714. [36] Negishi, K

  9. Angle closure glaucoma in congenital ectropion uvea.

    Science.gov (United States)

    Wang, Grace M; Thuente, Daniel; Bohnsack, Brenda L

    2018-06-01

    Congenital ectropion uvea is a rare anomaly, which is associated with open, but dysplastic iridocorneal angles that cause childhood glaucoma. Herein, we present 3 cases of angle-closure glaucoma in children with congenital ectropion uvea. Three children were initially diagnosed with unilateral glaucoma secondary to congenital ectropion uvea at 7, 8 and 13 years of age. The three cases showed 360° of ectropion uvea and iris stromal atrophy in the affected eye. In one case, we have photographic documentation of progression to complete angle closure, which necessitated placement of a glaucoma drainage device 3 years after combined trabeculotomy and trabeculectomy. The 2 other cases, which presented as complete angle closure, also underwent glaucoma drainage device implantation. All three cases had early glaucoma drainage device encapsulation (within 4 months) and required additional surgery (cycloablation or trabeculectomy). Congenital ectropion uvea can be associated with angle-closure glaucoma, and placement of glaucoma drainage devices in all 3 of our cases showed early failure due to plate encapsulation. Glaucoma in congenital ectropion uvea requires attention to angle configuration and often requires multiple surgeries to obtain intraocular pressure control.

  10. Small angle spectrometers: Summary

    International Nuclear Information System (INIS)

    Courant, E.; Foley, K.J.; Schlein, P.E.

    1986-01-01

    Aspects of experiments at small angles at the Superconducting Super Collider are considered. Topics summarized include a small angle spectrometer, a high contingency spectrometer, dipole and toroid spectrometers, and magnet choices

  11. Contact Angle Goniometer

    Data.gov (United States)

    Federal Laboratory Consortium — Description:The FTA32 goniometer provides video-based contact angle and surface tension measurement. Contact angles are measured by fitting a mathematical expression...

  12. Change of the dominant luminescent mechanism with increasing current density in molecularly doped organic light-emitting devices

    International Nuclear Information System (INIS)

    Zhou Liang; Zhang Hongjie; Meng Qingguo; Liu Fengyi; Yu Jiangbo; Deng Ruiping; Peng Zeping; Li Zhefeng; Guo Zhiyong

    2007-01-01

    We have fabricated and measured a series of electroluminescent devices with the structure of ITO/TPD/Eu(TTA) 3 phen (x):CBP/BCP/ALQ/LiF/Al, where x is the weight percentage of Eu(TTA) 3 phen (from 0% to 6%). At very low current density, carrier trapping is the dominant luminescent mechanism and the 4% doped device shows the highest electroluminescence (EL) efficiency among all these devices. With increasing current density, Foerster energy transfer participates in EL process. At the current density of 10.0 and 80.0 mA/cm 2 , 2% and 3% doped devices show the highest EL efficiency, respectively. From analysis of the EL spectra and the EL efficiency-current density characteristics, we found that the EL efficiency is manipulated by Foerster energy transfer efficiency at high current density. So we suggest that the dominant luminescent mechanism changes gradually from carrier trapping to Foerster energy transfer with increasing current density. Moreover, the conversion of dominant EL mechanism was suspected to be partly responsible for the EL efficiency roll-off because of the lower EL quantum efficiency of Foerster energy transfer compared with carrier trapping

  13. WORM memory devices based on conformation change of a PVK derivative with a rigid spacer in side chain

    International Nuclear Information System (INIS)

    Liu Yuanhua; Li Najun; Xia Xuewei; Xu Qingfeng; Ge Jianfeng; Lu Jianmei

    2010-01-01

    A nonvolatile write-once-read-many-times (WORM) memory device based on poly((4-vinylbenzyl)-9H-carbazole) (PVCz) was fabricated by a simple and conventional process. The as-fabricated device was found to be at its OFF state and could be programmed irreversibly to the ON state with a low transition voltage of -1.7 V. The device exhibits a high ON/OFF current ratio of up to 10 6 , high stability in retention time up to 8 h and number of read cycles up to 10 8 under a read voltage of -1.0 V in both ON and OFF states. The results of X-ray diffraction (XRD) and fluorescence emission spectra in different states of PVCz indicate that the electrical bistable phenomenon is caused by the voltage-induced conformation change of the pendant carbazole groups. With high performance, low power consumption and low production cost, the device fabricated with PVCz has a potential application for nonvolatile memory.

  14. Characterizations and thermal stability improvement of phase-change memory device containing Ce-doped GeSbTe films

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Yu-Jen; Tsai, Min-Chuan; Wang, Chiung-Hsin; Hsieh, Tsung-Eong, E-mail: tehsieh@mail.nctu.edu.tw

    2012-02-29

    Phase-transition temperature of GeSbTe (GST) chalcogenide film was drastically increased from 159 to 236 Degree-Sign C by cerium (Ce) doping (up to 8.6 at.%) without altering the resistivity property of GST. Grain refinement via the solid-solution mechanism and the amplification of p-type semiconducting behavior in Ce-doped GST were observed. They were correlated with the enhancement of thermal stability and data retention property of GST as revealed by exothermal and isothermal analyses. Phase-change memory (PCM) device characterized at various temperatures revealed an effective thermal stability improvement on the threshold voltage of PCM device by Ce doping. - Highlights: Black-Right-Pointing-Pointer Ce doping increased phase-change temperature of GST from 159 to 236 Degree-Sign C. Black-Right-Pointing-Pointer No suppression of resistivity level in amorphous Ce-doped GST. Black-Right-Pointing-Pointer Resistance ratio of amorphous and crystalline Ce-doped GST was preserved at 10{sup 5}. Black-Right-Pointing-Pointer p-type semiconducting behavior of GST was enhanced by Ce-doping. Black-Right-Pointing-Pointer Ce-doping improved the thermal stability of threshold voltage of GST PCM device.

  15. Light Scattering at Various Angles

    Science.gov (United States)

    Latimer, Paul; Pyle, B. E.

    1972-01-01

    The Mie theory of scattering is used to provide new information on how changes in particle volume, with no change in dry weight, should influence light scattering for various scattering angles and particle sizes. Many biological cells (e.g., algal cells, erythrocytes) and large subcellular structures (e.g., chloroplasts, mitochondria) in suspension undergo this type of reversible volume change, a change which is related to changes in the rates of cellular processes. A previous study examined the effects of such volume changes on total scattering. In this paper scattering at 10° is found to follow total scattering closely, but scattering at 45°, 90°, 135°, and 170° behaves differently. Small volume changes can cause very large observable changes in large angle scattering if the sample particles are uniform in size; however, the natural particle size heterogeneity of most samples would mask this effect. For heterogeneous samples of most particle size ranges, particle shrink-age is found to increase large angle scattering. PMID:4556610

  16. Loop-Mediated Isothermal Amplification Using a Lab-on-a-Disc Device with Thin-film Phase Change Material.

    Science.gov (United States)

    Ko, Junguk; Yoo, Jae-Chern

    2018-03-05

    The design and fabrication of temperature measurement systems that facilitate successful realization of DNA amplification using a lab-on-a-disc (LOD) device are a highly challenging task. The major challenge lies in the fact that such a system must be directly attached to a heating chamber in a way that enables the accurate measurement of temperature of the chamber while allowing the LOD to rotate. This paper presents a temperature control system for implementing isothermal amplification of DNA samples using an LOD device. The proposed system utilizes a thin-film phase change material and non-contact heating system to remotely measure the actual temperature of the chamber and, if required, rapidly heat it to the desired temperature. The results of the experiments performed in this study demonstrate that the proposed system provides an automated platform for molecular amplification and exhibits an operational performance comparable to that of traditional microcentrifuge tube-based isothermal amplification systems.

  17. An economic evaluation of adaptive e-learning devices to promote weight loss via dietary change for people with obesity

    Directory of Open Access Journals (Sweden)

    Miners Alec

    2012-07-01

    Full Text Available Abstract Background The prevalence of obesity is over 25 % in many developed countries. Obesity is strongly associated with an increased risk of fatal and chronic conditions such as cardiovascular disease and type 2 diabetes. Therefore it has become a major public health concern for many economies. E-learning devices are a relatively novel approach to promoting dietary change. The new generation of devices are ‘adaptive’ and use interactive electronic media to facilitate teaching and learning. E-Learning has grown out of recent developments in information and communication technology, such as the Internet, interactive computer programmes, interactive television and mobile phones. The aim of this study is to assess the cost-effectiveness of e-learning devices as a method of promoting weight loss via dietary change. Methods An economic evaluation was performed using decision modelling techniques. Outcomes were expressed in terms of Quality-Adjusted Life-Years (QALYs and costs were estimated from a health services perspective. All parameter estimates were derived from the literature. A systematic review was undertaken to derive the estimate of relative treatment effect. Results The base case results from the e-Learning Economic Evaluation Model (e-LEEM suggested that the incremental cost-effectiveness ratio was approximately £102,000 per Quality-Adjusted Life-Year (QALY compared to conventional care. This finding was robust to most alternative assumptions, except a much lower fixed cost of providing e-learning devices. Expected value of perfect information (EVPI analysis showed that while the individual level EVPI was arguably negligible, the population level value was between £37 M and £170 M at a willingness to pay between £20,000 to £30,000 per additional QALY. Conclusion The current economic evidence base suggests that e-learning devices for managing the weight of obese individuals are unlikely to be cost-effective unless their

  18. An economic evaluation of adaptive e-learning devices to promote weight loss via dietary change for people with obesity.

    Science.gov (United States)

    Miners, Alec; Harris, Jody; Felix, Lambert; Murray, Elizabeth; Michie, Susan; Edwards, Phil

    2012-07-07

    The prevalence of obesity is over 25 % in many developed countries. Obesity is strongly associated with an increased risk of fatal and chronic conditions such as cardiovascular disease and type 2 diabetes. Therefore it has become a major public health concern for many economies. E-learning devices are a relatively novel approach to promoting dietary change. The new generation of devices are 'adaptive' and use interactive electronic media to facilitate teaching and learning. E-Learning has grown out of recent developments in information and communication technology, such as the Internet, interactive computer programmes, interactive television and mobile phones. The aim of this study is to assess the cost-effectiveness of e-learning devices as a method of promoting weight loss via dietary change. An economic evaluation was performed using decision modelling techniques. Outcomes were expressed in terms of Quality-Adjusted Life-Years (QALYs) and costs were estimated from a health services perspective. All parameter estimates were derived from the literature. A systematic review was undertaken to derive the estimate of relative treatment effect. The base case results from the e-Learning Economic Evaluation Model (e-LEEM) suggested that the incremental cost-effectiveness ratio was approximately £102,000 per Quality-Adjusted Life-Year (QALY) compared to conventional care. This finding was robust to most alternative assumptions, except a much lower fixed cost of providing e-learning devices. Expected value of perfect information (EVPI) analysis showed that while the individual level EVPI was arguably negligible, the population level value was between £37 M and £170 M at a willingness to pay between £20,000 to £30,000 per additional QALY. The current economic evidence base suggests that e-learning devices for managing the weight of obese individuals are unlikely to be cost-effective unless their fixed costs are much lower than estimated or future devices prove to

  19. Deposition and Characterization of CVD-Grown Ge-Sb Thin Film Device for Phase-Change Memory Application

    Directory of Open Access Journals (Sweden)

    C. C. Huang

    2012-01-01

    Full Text Available Germanium antimony (Ge-Sb thin films with tuneable compositions have been fabricated on SiO2/Si, borosilicate glass, and quartz glass substrates by chemical vapour deposition (CVD. Deposition takes place at atmospheric pressure using metal chloride precursors at reaction temperatures between 750 and 875°C. The compositions and structures of these thin films have been characterized by micro-Raman, scanning electron microscope (SEM with energy dispersive X-ray analysis (EDX and X-ray diffraction (XRD techniques. A prototype Ge-Sb thin film phase-change memory device has been fabricated and reversible threshold and phase-change switching demonstrated electrically, with a threshold voltage of 2.2–2.5 V. These CVD-grown Ge-Sb films show promise for applications such as phase-change memory and optical, electronic, and plasmonic switching.

  20. Transverse Carpal Ligament and Forearm Fascia Release for the Treatment of Carpal Tunnel Syndrome Change the Entrance Angle of Flexor Tendons to the A1 Pulley: The Relationship between Carpal Tunnel Surgery and Trigger Finger Occurence

    Directory of Open Access Journals (Sweden)

    Nazım Karalezli

    2013-01-01

    Full Text Available Purpose. The appearance of trigger finger after decompression of the carpal tunnel without a preexisting symptom has been reported in a few articles. Although, the cause is not clear yet, the loss of pulley action of the transverse carpal ligament has been accused mostly. In this study, we planned a biomechanical approach to fresh cadavers. Methods. The study was performed on 10 fresh amputees of the arm. The angles were measured with (1 the transverse carpal ligament and the distal forearm fascia intact, (2 only the transverse carpal ligament incised, (3 the distal forearm fascia incised to the point 3 cm proximal from the most proximal part of the transverse carpal ligament in addition to the transverse carpal ligament. The changes between the angles produced at all three conditions were compared to each other. Results. We saw that the entrance angle increased in all of five fingers in an increasing manner from procedure 1 to 3, and it was seen that the maximal increase is detected in the middle finger from procedure 1 to procedure 2 and the minimal increase is detected in little finger. Discussion. Our results support that transverse carpal ligament and forearm fascia release may be a predisposing factor for the development of trigger finger by the effect of changing the enterance angle to the A1 pulley and consequently increase the friction in this anatomic area. Clinical Relevance. This study is a cadaveric study which is directly investigating the effect of a transverse carpal ligament release on the enterance angle of flexor tendons to A1 pulleys in the hand.

  1. Surface morphological changes on the human dental enamel and cement after the Er:YAG laser irradiation at different incidence angles

    International Nuclear Information System (INIS)

    Tannous, Jose Trancoso

    2001-01-01

    This is a morphological analysis study through SEM of the differences of the laser tissue interaction as a function of the laser beam irradiation angle, under different parameters of energy. Fourteen freshly extracted molars stored in a 0,9% sodium chloride solution were divided in seven pairs and were irradiated with 100, 200, 300, 400, 500, 600 and 700 mJ per pulse, respectively. Each sample received three enamel irradiations and three cement irradiations, either in the punctual or in the contact mode, one near to the other, with respectively 30, 45 and 90 inclinations degrees of dental surface-laser-beam incidence. Four Er:YAG pulses (2,94 μm, 7-20 Hz, 0,1-1 J energy/pulse - Opus 20 - Opus Dent) with water cooling system (0,4 ml/s) were applied. After the laser irradiation the specimens were analysed through scanning electron microscope (SEM). The results were analysed by SEM micrographs showing a great difference on the laser tissue interaction characteristics as a function of the irradiation angle of the laser beam. All the observations led to conclude that, considering the laser parameters used, the incidence angle variation is a very important parameter regarding the desired morphological effects. This represents an extremely relevant detail on the technical description of the Er:YAG laser irradiation protocols on dental tissues. (author)

  2. An Ontology of Omnipresent and Omniscient Cameras: Changes to Telejournalism and the Ubiquity of Devices for Recording Reality

    Directory of Open Access Journals (Sweden)

    Maura Martins

    2016-12-01

    Full Text Available The proliferation of technological devices that visually register the world has led to changes in the narrative formats of telejournalism. The various types of cameras used by television stations – surveillance, amateur, hidden and even professional ones - give broadcasters a plethora of strategies for reaching an audience who tend to dominate and distrust the well-known media languages. This paper presents a proposal for categorizing the cameras used in daily telejournalism in order to better understand the specifics of the phenomenon. Overall, all these cameras appear to be used for creating a realist aesthetic with low media interference.

  3. Surface texture change on-demand and microfluidic devices based on thickness mode actuation of dielectric elastomer actuators (DEAs)

    Science.gov (United States)

    Ankit, Ankit; Nguyen, Anh Chien; Mathews, Nripan

    2017-04-01

    Tactile feedback devices and microfluidic devices have huge significance in strengthening the area of robotics, human machine interaction and low cost healthcare. Dielectric Elastomer Actuators (DEAs) are an attractive alternative for both the areas; offering the advantage of low cost and simplistic fabrication in addition to the high actuation strains. The inplane deformations produced by the DEAs can be used to produce out-of-plane deformations by what is known as the thickness mode actuation of DEAs. The thickness mode actuation is achieved by adhering a soft passive layer to the DEA. This enables a wide area of applications in tactile applications without the need of complex systems and multiple actuators. But the thickness mode actuation has not been explored enough to understand how the deformations can be improved without altering the material properties; which is often accompanied with increased cost and a trade off with other closely associated material properties. We have shown the effect of dimensions of active region and non-active region in manipulating the out-of-plane deformation. Making use of this, we have been able to demonstrate large area devices and complex patterns on the passive top layer for the surface texture change on-demand applications. We have also been able to demonstrate on-demand microfluidic channels and micro-chambers without the need of actually fabricating the channels; which is a cost incurring and cumbersome process.

  4. The impact of changes in LVEF and renal function on the prognosis of ICD patients after elective device replacement.

    Science.gov (United States)

    Vandenberk, Bert; Robyns, Tomas; Garweg, Christophe; Floré, Vincent; Foulon, Stefaan; Voros, Gabor; Ector, Joris; Willems, Rik

    2017-10-01

    A proportion of patients with an implantable cardioverter-defibrillator (ICD) in prevention of sudden cardiac death will only receive their first appropriate ICD therapy (AT) after device replacement. Clinical reassessment at the time of replacement could be helpful to guide the decision to replace or not in the future. All patients with an ICD for primary or secondary prevention in ischemic (ICM) or nonischemic cardiomyopathy were included in a single-center retrospective registry. The association of changes in left ventricular ejection fraction (LVEF; cut-off at 35%), worsening renal function (decrease in estimated glomerular filtration rate > 15 mL/min), and worsening New York Heart Association class at elective device replacement with mortality and AT was analyzed using adjusted Cox regression analysis. A total of 238 (33%) out of 727 patients received elective device replacement (86.1% male, 74.4% ICM, 42.9% primary prevention). During this replacement 20.2% received a device upgrade. The mean time to replacement was 6.4 ± 2.0 years and mean follow-up after replacement was 3.4 ± 3.0 years. Of patients who did not receive AT before replacement 23.1% received their first AT after replacement. Worsening renal function (hazard ratio [HR] 2.79, 95% confidence interval [CI] 1.50-5.18) and a consistently LVEF ≤35% compared to a consistently LVEF >35% (HR 2.15, 95% CI 1.10-4.19) at the time of replacement were independent predictors of mortality. Independent predictors of first AT after replacement could not be identified. Although reassessment of LVEF and renal function at replacement can be helpful in predicting total mortality, the clinical utility to guide reimplantation seemed limited. Our experience indicates that approximately 25% of patients received their first AT only after replacement. © 2017 Wiley Periodicals, Inc.

  5. The Steerable Microcatheter: A New Device for Selective Catheterisation

    Energy Technology Data Exchange (ETDEWEB)

    Soyama, Takeshi [Hokkaido University Hospital, Department of Diagnostic and Interventional Radiology (Japan); Yoshida, Daisuke [Sapporo Yamanoue Hospital, Department of Radiology (Japan); Sakuhara, Yusuke, E-mail: yusaku@med.hokudai.ac.jp; Morita, Ryo; Abo, Daisuke; Kudo, Kohsuke [Hokkaido University Hospital, Department of Diagnostic and Interventional Radiology (Japan)

    2017-06-15

    The steerable microcatheter (SwiftNINJA, Sumitomo Bakelite, Tokyo, Japan), which has a remote-controlled flexible tip manipulated using a dial in the handgrip, was recently developed and delivered to the market. This device enables the user to change the angle of the microcatheter tip manually, and potentially makes selective catheterisation easier. We evaluated its unique characteristics and utility in selective catheterisation and coil embolization. This article describes: (1) the advantages of this device in catheterisations involving acute angle branches, and (2) a new technique of compact coil packing with the use of intentional folding by the bendable tip of the catheter.

  6. The Steerable Microcatheter: A New Device for Selective Catheterisation

    International Nuclear Information System (INIS)

    Soyama, Takeshi; Yoshida, Daisuke; Sakuhara, Yusuke; Morita, Ryo; Abo, Daisuke; Kudo, Kohsuke

    2017-01-01

    The steerable microcatheter (SwiftNINJA, Sumitomo Bakelite, Tokyo, Japan), which has a remote-controlled flexible tip manipulated using a dial in the handgrip, was recently developed and delivered to the market. This device enables the user to change the angle of the microcatheter tip manually, and potentially makes selective catheterisation easier. We evaluated its unique characteristics and utility in selective catheterisation and coil embolization. This article describes: (1) the advantages of this device in catheterisations involving acute angle branches, and (2) a new technique of compact coil packing with the use of intentional folding by the bendable tip of the catheter.

  7. Vaginal flora changes on Pap smears after insertion of levonorgestrel-releasing intrauterine device.

    Science.gov (United States)

    Donders, Gilbert G G; Berger, Judith; Heuninckx, Hélène; Bellen, Gert; Cornelis, Ann

    2011-04-01

    The levonorgestrel intrauterine system (LNG-IUS) combines a uterine foreign body and the continuous release of low-dose levonorgestrel for contraception. Its influence on the rate of vulvovaginal infections and flora disturbance is insufficiently known, but important for contraceptive advice in women, especially those who develop recurrent vaginosis or Candida vulvovaginitis. Slides of 286 women who had a Pap smear taken before and 1 to 2 years after placement of a LNG-IUS were blindly reviewed for the presence of abnormal vaginal flora (AVF), bacterial vaginosis (BV), aerobic vaginitis (AV) and Candida vaginitis (CV). Prior to insertion, there were no differences in vaginal flora abnormalities between women using different kinds of contraception. LNG-IUS users did not have different rates of AVF, BV, AV or CV, but the general risk to develop any infection was increased. Uterine bleeding after insertion did not seem to predict a different flora type. We found that Pap smears suggested more vaginal infections after 1 year of LNG-IUS use than prior to insertion of the device. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Changes in functional connectivity correlate with behavioral gains in stroke patients after therapy using a brain-computer interface device

    Directory of Open Access Journals (Sweden)

    Brittany Mei Young

    2014-07-01

    Full Text Available Brain-computer interface (BCI technology is being incorporated into new stroke rehabilitation devices, but little is known about brain changes associated with its use. We collected anatomical and functional MRI of 9 stroke patients with persistent upper extremity motor impairment before, during, and after therapy using a BCI system. Subjects were asked to perform finger tapping of the impaired hand during fMRI. Action Research Arm Test (ARAT, 9-Hole Peg Test (9-HPT, and Stroke Impact Scale (SIS domains of Hand Function (HF and Activities of Daily Living (ADL were also assessed. Group-level analyses examined changes in whole-brain task-based functional connectivity (FC to seed regions in the motor network observed during and after BCI therapy. Whole-brain FC analyses seeded in each thalamus showed FC increases from baseline at mid-therapy and post-therapy (p< 0.05. Changes in FC between seeds at both the network and the connection levels were examined for correlations with changes in behavioral measures. Average motor network FC was increased post-therapy, and changes in average network FC correlated (p < 0.05 with changes in performance on ARAT (R2=0.21, 9-HPT (R2=0.41, SIS HF (R2=0.27, and SIS ADL (R2=0.40. Multiple individual connections within the motor network were found to correlate in change from baseline with changes in behavioral measures. Many of these connections involved the thalamus, with change in each of four behavioral measures significantly correlating with change from baseline FC of at least one thalamic connection. These preliminary results show changes in FC that occur with the administration of rehabilitative therapy using a BCI system. The correlations noted between changes in FC measures and changes in behavioral outcomes indicate that both adaptive and maladaptive changes in FC may develop with this therapy and also suggest a brain-behavior relationship that may be stimulated by the neuromodulatory component of BCI therapy.

  9. Chemically driven switches for online detection of pH changes in microfluidic devices

    NARCIS (Netherlands)

    Mela, P.; Onclin, S.; Goedbloed, M.H.; Levi, S.; Levi, S.A.; van Hulst, N.F.; van den Berg, Albert

    2003-01-01

    The internal walls of microfabricated fluidic channels were functionalized with a selfassembled monolayer of Rhodamine B lactam. This molecule has the capability to interconvert between its open fluorescent amide form and the closed non-fluorescent lactam form upon changes of the pH conditions. The

  10. Consideration of Shoulder Joint's Image with the Changed Tube Angle of the Shoulder Oblique Projection in Supine Position

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jae Hyun; Choi, Nam Gil [Dept. of Radiology, Chonnam National University Hospital, Kwangju (Korea, Republic of)

    2008-06-15

    There is a standard shoulder oblique method (Grashey method) available to view the shoulder joint. This method projects AP view of the shoulder joint so that the Humerus head's subuxation or joint degeneration can be easily visualized. However, in this view, the patients, with supine or sitting or erect position, have to keep their body obliquely. Whereas, the patients who are not well or operated, usually feel very uncomfortable to keep their body in this position and hence, we need other persons' help and much efforts will be needed to get the good quality shoulder joint view. Therefore, we thought of examining a method which shows the joint well by angling the tube to Medio-Lateral direction and without keeping the patients' one side upward in supine position. For this study, total 15 subjects with no history of neurological or psychiatric illness, were recruited for examinations. They consisted of 9 males and 6 females. Statistic group analysis was performed with ANOVA test. Scores of the evaluation of the experts were 1.01{+-}0.54 at 25 degrees, 2.50{+-}0.50 at 30 degrees, 2.85{+-}0.36 at 35 degrees and 2.33{+-}0.47 at 40 degrees, respectively, and they were significant(p<0.05, Table 1). Joint space of the Humerus head and Scapula were well distinguished at 35 degrees, 30 degrees and 40 degrees with the almost same score. However, the degree of distortion at 40 degrees was more severe than that at 30 degrees. Ultimately, 30-35 degrees views were shown to yield good quality shoulder oblique images. In conclusion, this method may be very useful for the patients who are uncomfortable and for the emergency patients. In order to get similar or comparable view, the same X-tube angle is recommended to be used before and after the operation. Therefore, we hope that this new angled method seems to be efficient.

  11. Comparison of fasciotomy wound closures using traditional dressing changes and the vacuum-assisted closure device.

    Science.gov (United States)

    Zannis, John; Angobaldo, Jeff; Marks, Malcolm; DeFranzo, Anthony; David, Lisa; Molnar, Joseph; Argenta, Louis

    2009-04-01

    Fasciotomy wounds can be a major contributor to length of stay for patients as well as a difficult reconstructive challenge. Once the compartment pressure has been relieved and stabilized, the wound should be closed as quickly and early as possible to avoid later complications. Skin grafting can lead to morbidity and scarring at both the donor and fasciotomy site. Primary closure results in a more functional and esthetic outcome with less morbidity for the patient, but can often be difficult to achieve secondary to edema, skin retraction, and skin edge necrosis. Our objective was to examine fasciotomy wound outcomes, including time to definitive closure, comparing traditional wet-to-dry dressings, and the vacuum-assisted closure (VAC) device. This retrospective chart review included a consecutive series of patients over a 10-year period. This series included 458 patients who underwent 804 fasciotomies. Of these fasciotomy wounds, 438 received exclusively VAC. dressings, 270 received only normal saline wet-to-dry dressings, and 96 were treated with a combination of both. Of the sample, 408 patients were treated with exclusively VAC therapy or wet-to-dry dressings and 50 patients were treated with a combination of both. In comparing all wounds, there was a statistically significant higher rate of primary closure using the VAC versus traditional wet-to-dry dressings (P lower extremities and P extremities). The time to primary closure of wounds was shorter in the VAC. group in comparison with the non-VAC group. This study has shown that the use of the VAC for fasciotomy wound closure results in a higher rate of primary closure versus traditional wet-to-dry dressings. In addition, the time to primary closure of wounds or time to skin grafting is shorter when the VAC was employed. The VAC used in the described settings decreases hospitalization time, allows for earlier rehabilitation, and ultimately leads to increased patient satisfaction.

  12. Reactive Ion Etching as Cleaning Method Post Chemical Mechanical Polishing for Phase Change Memory Device

    International Nuclear Information System (INIS)

    Min, Zhong; Zhi-Tang, Song; Bo, Liu; Song-Lin, Feng; Bomy, Chen

    2008-01-01

    In order to improve nano-scale phase change memory performance, a super-clean interface should be obtained after chemical mechanical polishing (CMP) of Ge 2 Sb 2 Te 5 phase change films. We use reactive ion etching (RIE) as the cleaning method. The cleaning effect is analysed by scanning electron microscopy and an energy dispersive spectrometer. The results show that particle residue on the surface has been removed. Meanwhile, Ge 2 Sb 2 Te 5 material stoichiometric content ratios are unchanged. After the top electrode is deposited, current-voltage characteristics test demonstrates that the set threshold voltage is reduced from 13 V to 2.7V and the threshold current from 0.1mA to 0.025mA. Furthermore, we analyse the RIE cleaning principle and compare it with the ultrasonic method

  13. Angle comparison using an autocollimator

    Science.gov (United States)

    Geckeler, Ralf D.; Just, Andreas; Vasilev, Valentin; Prieto, Emilio; Dvorácek, František; Zelenika, Slobodan; Przybylska, Joanna; Duta, Alexandru; Victorov, Ilya; Pisani, Marco; Saraiva, Fernanda; Salgado, Jose-Antonio; Gao, Sitian; Anusorn, Tonmueanwai; Leng Tan, Siew; Cox, Peter; Watanabe, Tsukasa; Lewis, Andrew; Chaudhary, K. P.; Thalmann, Ruedi; Banreti, Edit; Nurul, Alfiyati; Fira, Roman; Yandayan, Tanfer; Chekirda, Konstantin; Bergmans, Rob; Lassila, Antti

    2018-01-01

    Autocollimators are versatile optical devices for the contactless measurement of the tilt angles of reflecting surfaces. An international key comparison (KC) on autocollimator calibration, EURAMET.L-K3.2009, was initiated by the European Association of National Metrology Institutes (EURAMET) to provide information on the capabilities in this field. The Physikalisch-Technische Bundesanstalt (PTB) acted as the pilot laboratory, with a total of 25 international participants from EURAMET and from the Asia Pacific Metrology Programme (APMP) providing measurements. This KC was the first one to utilise a high-resolution electronic autocollimator as a standard. In contrast to KCs in angle metrology which usually involve the full plane angle, it focused on relatively small angular ranges (+/-10 arcsec and +/-1000 arcsec) and step sizes (10 arcsec and 0.1 arcsec, respectively). This document represents the approved final report on the results of the KC. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Optimal reconstruction angles

    International Nuclear Information System (INIS)

    Cook, G.O. Jr.; Knight, L.

    1979-07-01

    The question of optimal projection angles has recently become of interest in the field of reconstruction from projections. Here, studies are concentrated on the n x n pixel space, where literative algorithms such as ART and direct matrix techniques due to Katz are considered. The best angles are determined in a Gauss--Markov statistical sense as well as with respect to a function-theoretical error bound. The possibility of making photon intensity a function of angle is also examined. Finally, the best angles to use in an ART-like algorithm are studied. A certain set of unequally spaced angles was found to be preferred in several contexts. 15 figures, 6 tables

  15. Instrument-free exothermic heating with phase change temperature control for paper microfluidic devices

    Science.gov (United States)

    Singleton, Jered; Zentner, Chris; Buser, Josh; Yager, Paul; LaBarre, Paul; Weigl, Bernhard H.

    2013-03-01

    Many infectious diseases, as well as some cancers, that affect global health are most accurately diagnosed through nucleic acid amplification and detection. There is a great need to simplify nucleic acid-based assay systems for use in global health in low-resource settings as well as in settings that do not have convenient access to laboratory staff and equipment such as doctors' offices and home care settings. In developing countries, unreliable electric power, inadequate supply chains, and lack of maintenance for complex diagnostic instruments are all common infrastructure shortfalls. Many elements of instrument-free, disposable, nucleic acid amplification assays have been demonstrated in recent years. However, the problem of instrument-free,1 low-cost, temperature-controlled chemical heating remains unsolved. In this paper we present the current status and results of work towards developing disposable, low-cost, temperature-controlled heaters designed to support isothermal nucleic acid amplification assays that are integrated with a two-dimensional paper network. Our approach utilizes the heat generated through exothermic chemical reactions and controls the heat through use of engineered phase change materials to enable sustained temperatures required for nucleic acid amplification. By selecting appropriate exothermic and phase change materials, temperatures can be controlled over a wide range, suitable for various isothermal amplification methods, and maintained for over an hour at an accuracy of +/- 1°C.

  16. The Effect of Changing Focal Trough in a Panoramic Device on the Accuracy of Distance Measurements

    Directory of Open Access Journals (Sweden)

    Mehrdad Abdinian

    2018-01-01

    Full Text Available >Introduction: Magnification and distortion are the most important limitations of panoramic radiography. The aim of this study was to determine the effects of changing focal trough option of Planmeca SCARA 3 on the accuracy of linear distance measurements.Materials and Methods: In this in-vitro study, 28 pieces of gutta-percha were attached to the assumptive place of each lost root of an adult dry skull with average size and normal shape. The actual measurements were obtained by a digital caliper. The panoramic images of the skull were taken in six different sizes and shapes of focal trough. This procedure was repeated ten times with new gutta-percha. Paired t-test was used to compare the values of different actual and radiographic images of gutta-percha dimensions.Results: The mean difference [standard deviation (SD] between actual measurement and panoramic radiography in the different groups was from 0.37 (1.1 to 0.58 (2.87 mm. The mean (SD difference of linear measurements between real and radiographic images was 0.52 (0.43 mm in average size, V-shaped group, which was statistically and clinically significant (P = 0.00.Conclusion: Changing the focal trough option of Planmeca SCARA 3 has minimal effects on the accuracy of linear measurements in panoramic radiographs.

  17. Optimum Tilt Angle at Tropical Region

    Directory of Open Access Journals (Sweden)

    S Soulayman

    2015-02-01

    Full Text Available : One of the important parameters that affect the performance of a solar collector is its tilt angle with the horizon. This is because of the variation of tilt angle changes the amount of solar radiation reaching the collector surface. Meanwhile, is the rule of thumb, which says that solar collector Equator facing position is the best, is valid for tropical region? Thus, it is required to determine the optimum tilt as for Equator facing and for Pole oriented collectors. In addition, the question that may arise: how many times is reasonable for adjusting collector tilt angle for a definite value of surface azimuth angle? A mathematical model was used for estimating the solar radiation on a tilted surface, and to determine the optimum tilt angle and orientation (surface azimuth angle for the solar collector at any latitude. This model was applied for determining optimum tilt angle and orientation in the tropical zones, on a daily basis, as well as for a specific period. The optimum angle was computed by searching for the values for which the radiation on the collector surface is a maximum for a particular day or a specific period. The results reveal that changing the tilt angle 12 times in a year (i.e. using the monthly optimum tilt angle maintains approximately the total amount of solar radiation near the maximum value that is found by changing the tilt angle daily to its optimum value. This achieves a yearly gain in solar radiation of 11% to 18% more than the case of a solar collector fixed on a horizontal surface.

  18. Comparison of optical coherence tomography findings and visual field changes in patients with primary open-angle glaucoma and amyotrophic lateral sclerosis.

    Science.gov (United States)

    Liu, Ziyuan; Wang, Hongli; Fan, Dongsheng; Wang, Wei

    2018-02-01

    Recent studies revealing genetic connection of primary open angle glaucoma (POAG) and amyotrophic lateral sclerosis (ALS) have received particular attention. Exploring the evidence for common pathogenesis of these two progressive neurological disorders may assist in understanding the mechanism and searching for new treatment. Retinal nerve fiber layer (RNFL) defect and corresponding visual field (VF) impairment are well known neuropathy signs in glaucoma. In our study, thickness of certain retinal layer in ALS patients was analyzed to detect ganglion cell's soma and axon, and for first time visual field was examined for ALS. The correlation of retinal involvement and ALS progression were also investigated. The results were compared with those of POAG. The study may provide new knowledge for these two neurodegenerative diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. A multicenter, retrospective chart review study comparing index therapy change rates in open-angle glaucoma or ocular hypertension patients newly treated with latanoprost or travoprost-Z monotherapy

    Directory of Open Access Journals (Sweden)

    Edward Deepak P

    2011-06-01

    Full Text Available Abstract Background Because latanoprost and the original formulation of travoprost that included benzalkonium chloride (BAK have been shown to be similar with regard to tolerability, we compared initial topical intraocular pressure (IOP-lowering medication change rates in patients newly treated with latanoprost or travoprost-Z monotherapy. Methods At 14 clinical practice sites, medical records were abstracted for patients with a diagnosis of open-angle glaucoma or ocular hypertension and who were ≥40 years of age, had a baseline and at least one follow-up visit, and had no prior history of ocular prostaglandin use. Data regarding demographics, ocular/systemic medical histories, clinical variables, therapy initiations and reasons for changes, adverse events, and resource utilization were recorded from randomly chosen eligible charts. Primary outcomes were rates of and reasons for changing from the initial therapy within six months and across the full study period (1000 days. Results Data from 900 medical charts (latanoprost, 632; travoprost-Z, 268 were included. For both cohorts, average follow-up was >1 year. Cohorts were similar with regard to age (median ~67 years, gender distribution (>50% female, and diagnosis (~80% with open-angle glaucoma. Within six months, rates of index therapy change for latanoprost versus travoprost-Z were 21.2% (134/632 and 28.7% (77/268, respectively (p = 0.0148; across the full study period, rates were 34.5% (218/632 and 45.2% (121/268, respectively (p = 0.0026. Among those who changed their index therapy, insufficient IOP control was the most commonly reported reason followed by adverse events; hyperemia was the most commonly reported adverse event at index therapy change. Conclusions In this "real world" study of changes in therapy in patients prescribed initial monotherapy with latanoprost with BAK or travoprost-Z with SofZia, medication changes were common in both treatment groups but statistically

  20. A multicenter, retrospective chart review study comparing index therapy change rates in open-angle glaucoma or ocular hypertension patients newly treated with latanoprost or travoprost-Z monotherapy.

    Science.gov (United States)

    Fain, Joel M; Kotak, Sameer; Mardekian, Jack; Bacharach, Jason; Edward, Deepak P; Rauchman, Steven; Brevetti, Teresa; Fox, Janet L; Lovelace, Cherie

    2011-06-13

    Because latanoprost and the original formulation of travoprost that included benzalkonium chloride (BAK) have been shown to be similar with regard to tolerability, we compared initial topical intraocular pressure (IOP)-lowering medication change rates in patients newly treated with latanoprost or travoprost-Z monotherapy. At 14 clinical practice sites, medical records were abstracted for patients with a diagnosis of open-angle glaucoma or ocular hypertension and who were ≥40 years of age, had a baseline and at least one follow-up visit, and had no prior history of ocular prostaglandin use. Data regarding demographics, ocular/systemic medical histories, clinical variables, therapy initiations and reasons for changes, adverse events, and resource utilization were recorded from randomly chosen eligible charts. Primary outcomes were rates of and reasons for changing from the initial therapy within six months and across the full study period (1000 days). Data from 900 medical charts (latanoprost, 632; travoprost-Z, 268) were included. For both cohorts, average follow-up was >1 year. Cohorts were similar with regard to age (median ~67 years), gender distribution (>50% female), and diagnosis (~80% with open-angle glaucoma). Within six months, rates of index therapy change for latanoprost versus travoprost-Z were 21.2% (134/632) and 28.7% (77/268), respectively (p = 0.0148); across the full study period, rates were 34.5% (218/632) and 45.2% (121/268), respectively (p = 0.0026). Among those who changed their index therapy, insufficient IOP control was the most commonly reported reason followed by adverse events; hyperemia was the most commonly reported adverse event at index therapy change. In this "real world" study of changes in therapy in patients prescribed initial monotherapy with latanoprost with BAK or travoprost-Z with SofZia, medication changes were common in both treatment groups but statistically significantly more frequent with travoprost-Z.

  1. Measurement of Angle Kappa Using Ultrasound Biomicroscopy and Corneal Topography.

    Science.gov (United States)

    Yeo, Joon Hyung; Moon, Nam Ju; Lee, Jeong Kyu

    2017-06-01

    To introduce a new convenient and accurate method to measure the angle kappa using ultrasound biomicroscopy (UBM) and corneal topography. Data from 42 eyes (13 males and 29 females) were analyzed in this study. The angle kappa was measured using Orbscan II and calculated with UBM and corneal topography. The angle kappa of the dominant eye was compared with measurements by Orbscan II. The mean patient age was 36.4 ± 13.8 years. The average angle kappa measured by Orbscan II was 3.98° ± 1.12°, while the average angle kappa calculated with UBM and corneal topography was 3.19° ± 1.15°. The difference in angle kappa measured by the two methods was statistically significant (p topography to calculate the angle kappa. This method is convenient to use and allows for measurement of the angle kappa without an expensive device. © 2017 The Korean Ophthalmological Society

  2. Nanoscale observations of the operational failure for phase-change-type nonvolatile memory devices using Ge2Sb2Te5 chalcogenide thin films

    International Nuclear Information System (INIS)

    Yoon, Sung-Min; Choi, Kyu-Jeong; Lee, Nam-Yeal; Lee, Seung-Yun; Park, Young-Sam; Yu, Byoung-Gon

    2007-01-01

    In this study, a phase-change memory device was fabricated and the origin of device failure mode was examined using transmission electron microscopy (TEM) and energy dispersive X-ray spectroscopy (EDS). Ge 2 Sb 2 Te 5 (GST) was used as the active phase-change material in the memory device and the active pore size was designed to be 0.5 μm. After the programming signals of more than 2x10 6 cycles were repeatedly applied to the device, the high-resistance memory state (reset) could not be rewritten and the cell resistance was fixed at the low-resistance state (set). Based on TEM and EDS studies, Sb excess and Ge deficiency in the device operating region had a strong effect on device reliability, especially under endurance-demanding conditions. An abnormal segregation and oxidation of Ge also was observed in the region between the device operating and inactive peripheral regions. To guarantee an data endurability of more than 1x10 10 cycles of PRAM, it is very important to develop phase-change materials with more stable compositions and to reduce the current required for programming

  3. Observation of reversible, rapid changes in drug susceptibility of hypoxic tumor cells in a microfluidic device.

    Science.gov (United States)

    Germain, Todd; Ansari, Megan; Pappas, Dimitri

    2016-09-14

    Hypoxia is a major stimulus for increased drug resistance and for survival of tumor cells. Work from our group and others has shown that hypoxia increases resistance to anti-cancer compounds, radiation, and other damage-pathway cytotoxic agents. In this work we utilize a microfluidic culture system capable of rapid switching of local oxygen concentrations to determine changes in drug resistance in prostate cancer cells. We observed rapid adaptation to hypoxia, with drug resistance to 2 μM staurosporine established within 30 min of hypoxia. Annexin-V/Sytox Green apoptosis assays over 9 h showed 78.0% viability, compared to 84.5% viability in control cells (normoxic cells with no staurosporine). Normoxic cells exposed to the same staurosporine concentration had a viability of 48.6% after 9 h. Hypoxia adaptation was rapid and reversible, with Hypoxic cells treated with 20% oxygen for 30 min responding to staurosporine with 51.6% viability after drug treatment for 9 h. Induction of apoptosis through the receptor-mediated pathway, which bypasses anti-apoptosis mechanisms induced by hypoxia, resulted in 39.4 ± 7% cell viability. The rapid reversibility indicates co-treatment of oxygen with anti-cancer compounds may be a potential therapeutic target. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Self-actuated rate of change of pressure scram device for nuclear reactors

    International Nuclear Information System (INIS)

    Noyes, R.C.; Zaman, S.U.; Stuteville, D.W.

    1979-01-01

    A sensor chamber having one cavity containing coolant separated by a diaphragm from another cavity containing a fixed mass of inert gas is located within a safety assembly of a liquid metal-cooled nuclear reactor. The liquid cavity is in fluid communication with the coolant outside the chamber through a flow limiting orifice. An actuating bellows in fluid communication with the gas cavity is in contact with coolant outside the chamber and is connected to a push rod, which serves as a trigger for a poison bundle relase mechanism. During slow changes in reactor coolant pressure experienced under normal operation, the diaphragm moves to equalize the gas cavity and liquid cavity pressures with the coolant pressure outside the chamber. The actuating bellows does not move because it is biased so that a threshold pressure difference is required before it will expand. Under a more rapid drop in coolant pressure, such as is associated with a loss of forced flow, the threshold is overcome and the actuating bellows will also move, thereby triggering the release mechanism to shut down the reactor. The actuating bellows may be connected to the liquid cavity rather than to the gas cavity

  5. Predictors of changes in health status between and within patients 12 months post left ventricular assist device implantation

    DEFF Research Database (Denmark)

    Brouwers, Corline; de Jonge, Nicolaas; Caliskan, Kadir

    2014-01-01

    improvements in health status between baseline and 3 months follow-up as assessed by the KCCQ (clinical summary score: F = 33.49, P physical component score: F = 31.59, P ... 3 months and 12 months follow-up (P > 0.05 for all). Higher scores on anxiety and depression over time, older age, lower ejection fraction, and more co-morbidity were associated with poorer health status scores on one or both of the KCCQ and SF-12 subscales. The majority of the between......BACKGROUND: Improving patient-reported outcomes (e.g. health status) has become an important goal in left ventricular assist device (LVAD) therapy, in addition to reducing mortality and morbidity. We examined predictors of changes in health status scores between and within patients 12 months post...

  6. Phase-change materials for non-volatile memory devices: from technological challenges to materials science issues

    Science.gov (United States)

    Noé, Pierre; Vallée, Christophe; Hippert, Françoise; Fillot, Frédéric; Raty, Jean-Yves

    2018-01-01

    Chalcogenide phase-change materials (PCMs), such as Ge-Sb-Te alloys, have shown outstanding properties, which has led to their successful use for a long time in optical memories (DVDs) and, recently, in non-volatile resistive memories. The latter, known as PCM memories or phase-change random access memories (PCRAMs), are the most promising candidates among emerging non-volatile memory (NVM) technologies to replace the current FLASH memories at CMOS technology nodes under 28 nm. Chalcogenide PCMs exhibit fast and reversible phase transformations between crystalline and amorphous states with very different transport and optical properties leading to a unique set of features for PCRAMs, such as fast programming, good cyclability, high scalability, multi-level storage capability, and good data retention. Nevertheless, PCM memory technology has to overcome several challenges to definitively invade the NVM market. In this review paper, we examine the main technological challenges that PCM memory technology must face and we illustrate how new memory architecture, innovative deposition methods, and PCM composition optimization can contribute to further improvements of this technology. In particular, we examine how to lower the programming currents and increase data retention. Scaling down PCM memories for large-scale integration means the incorporation of the PCM into more and more confined structures and raises materials science issues in order to understand interface and size effects on crystallization. Other materials science issues are related to the stability and ageing of the amorphous state of PCMs. The stability of the amorphous phase, which determines data retention in memory devices, can be increased by doping the PCM. Ageing of the amorphous phase leads to a large increase of the resistivity with time (resistance drift), which has up to now hindered the development of ultra-high multi-level storage devices. A review of the current understanding of all these

  7. Observation of reversible, rapid changes in drug susceptibility of hypoxic tumor cells in a microfluidic device

    Energy Technology Data Exchange (ETDEWEB)

    Germain, Todd; Ansari, Megan; Pappas, Dimitri, E-mail: d.pappas@ttu.edu

    2016-09-14

    Hypoxia is a major stimulus for increased drug resistance and for survival of tumor cells. Work from our group and others has shown that hypoxia increases resistance to anti-cancer compounds, radiation, and other damage-pathway cytotoxic agents. In this work we utilize a microfluidic culture system capable of rapid switching of local oxygen concentrations to determine changes in drug resistance in prostate cancer cells. We observed rapid adaptation to hypoxia, with drug resistance to 2 μM staurosporine established within 30 min of hypoxia. Annexin-V/Sytox Green apoptosis assays over 9 h showed 78.0% viability, compared to 84.5% viability in control cells (normoxic cells with no staurosporine). Normoxic cells exposed to the same staurosporine concentration had a viability of 48.6% after 9 h. Hypoxia adaptation was rapid and reversible, with Hypoxic cells treated with 20% oxygen for 30 min responding to staurosporine with 51.6% viability after drug treatment for 9 h. Induction of apoptosis through the receptor-mediated pathway, which bypasses anti-apoptosis mechanisms induced by hypoxia, resulted in 39.4 ± 7% cell viability. The rapid reversibility indicates co-treatment of oxygen with anti-cancer compounds may be a potential therapeutic target. - Highlights: • Microfluidic system switches rapidly between normoxia and hypoxia (5 min). • Observation of rapid adaptation of PC3 cells to hypoxia and normoxia (30 min). • Drug susceptibility in tumor cells restored after chip switched to normoxia for 30 min.

  8. Thermonuclear device

    International Nuclear Information System (INIS)

    Takano, Hirohisa; Nakamoto, Kazunari; Hanai, Satoshi.

    1984-01-01

    Purpose: To provide coils of high mechanical strength for use at the center of a torus type thermonuclear device. Constitution: A plurality of copper plates having cooling holes and bolt holes and insulation paper sheets of the same shape are prepared. The copper plate is different from the insulation paper sheet only in that the position-phase angle of the opening portion is larger by 15 - 30 0 . The copper plates and the insulation paper sheets are alternately stacked by a required number of turns while displacing the angle, and then clamped by bolts to form a mechanically strong coil with no metallurgical joining. Further, since the insulation paper sheets are not present in the radial direction and only one insulation paper sheet is inserted for each turn in the direction of the coil height, the space occupied by the coil can be decreased. According to this invention, the magnetic flux density at the center of the device can be increased as compared with the conventional case to thereby apply a higher voltage on the side of plasmas. (Moriyama, K.)

  9. Angles in hyperbolic lattices

    DEFF Research Database (Denmark)

    Risager, Morten S.; Södergren, Carl Anders

    2017-01-01

    It is well known that the angles in a lattice acting on hyperbolic n -space become equidistributed. In this paper we determine a formula for the pair correlation density for angles in such hyperbolic lattices. Using this formula we determine, among other things, the asymptotic behavior of the den......It is well known that the angles in a lattice acting on hyperbolic n -space become equidistributed. In this paper we determine a formula for the pair correlation density for angles in such hyperbolic lattices. Using this formula we determine, among other things, the asymptotic behavior...... of the density function in both the small and large variable limits. This extends earlier results by Boca, Pasol, Popa and Zaharescu and Kelmer and Kontorovich in dimension 2 to general dimension n . Our proofs use the decay of matrix coefficients together with a number of careful estimates, and lead...

  10. Deformable paper origami optoelectronic devices

    KAUST Repository

    He, Jr-Hau

    2017-01-19

    Deformable optoelectronic devices are provided, including photodetectors, photodiodes, and photovoltaic cells. The devices can be made on a variety of paper substrates, and can include a plurality of fold segments in the paper substrate creating a deformable pattern. Thin electrode layers and semiconductor nanowire layers can be attached to the substrate, creating the optoelectronic device. The devices can be highly deformable, e.g. capable of undergoing strains of 500% or more, bending angles of 25° or more, and/or twist angles of 270° or more. Methods of making the deformable optoelectronic devices and methods of using, e.g. as a photodetector, are also provided.

  11. Sample processing device and method

    DEFF Research Database (Denmark)

    2011-01-01

    A sample processing device is disclosed, which sample processing device comprises a first substrate and a second substrate, where the first substrate has a first surface comprising two area types, a first area type with a first contact angle with water and a second area type with a second contact...... angle with water, the first contact angle being smaller than the second contact angle. The first substrate defines an inlet system and a preparation system in areas of the first type which two areas are separated by a barrier system in an area of the second type. The inlet system is adapted to receive...

  12. Contact angles on stretched solids

    Science.gov (United States)

    Mensink, Liz; Snoeijer, Jacco

    2017-11-01

    The surface energy of solid interfaces plays a central role in wetting, as they dictate the liquid contact angle. Yet, it has been challenging to measure the solid surface energies independently, without making use of Young's law. Here we present Molecular Dynamics (MD) simulations by which we measure the surface properties for all interfaces, including the solids. We observe change in contact angles upon stretching the solid substrates, showing that the surface energy is actually strain dependent. This is clear evidence of the so-called Shuttleworth effect, making it necessary to distinguish surface energy from surface tension. We discuss how this effect gives rise to a new class of elasto-capillary phenomena. ERC Consolidator Grant No. 616918.

  13. Microfluidic Device to Measure the Speed of C. elegans Using the Resistance Change of the Flexible Electrode

    Directory of Open Access Journals (Sweden)

    Jaehoon Jung

    2016-03-01

    Full Text Available This work presents a novel method to assess the condition of Caenorhabditis elegans (C. elegans through a resistance measurement of its undulatory locomotion speed inside a micro channel. As the worm moves over the electrode inside the micro channel, the length of the electrode changes, consequently behaving like a strain gauge. In this paper, the electrotaxis was applied for controlling the direction of motion of C. elegans as an external stimulus, resulting in the worm moving towards the cathode of the circuit. To confirm the proposed measurement method, a microfluidic device was developed that employs a sinusoidal channel and a thin polydimethylsiloxane (PDMS layer with an electrode. The PDMS layer maintains a porous structure to enable the flexibility of the electrode. In this study, 6 measurements were performed to obtain the speed of an early adult stage C. elegans, where the measured average speed was 0.35 (±0.05 mm/s. The results of this work demonstrate the application of our method to measure the speed of C. elegans undulatory locomotion. This novel approach can be applied to make such measurements without an imaging system, and more importantly, allows directly to detect the locomotion of C. elegans using an electrical signal (i.e., the change in resistance.

  14. Implementation of electronic locking devices for adolescents at German tobacco vending machines: intended and unintended changes of supply and demand.

    Science.gov (United States)

    Schneider, S; Meyer, C; Yamamoto, S; Solle, D

    2009-08-01

    Starting from 1 January 2007, electronic locking devices based on proof-of-age (via electronic cash cards or a European driving licence) were installed in approximately 500,000 vending machines across Germany to restrict the purchase of cigarettes to those over the age of 16. To examine changes in the number of tobacco vending machines before and after the introduction of these new measures. The total number of commercial tobacco sources in 2 selected districts (70,000 inhabitants) in Cologne were recorded and mapped. This major German city was the ideal setting for this study as investigators were able to use existing sociogeographical data from the area. A complete inventory was compiled in autumn 2005 and 2007. A total of 780 students aged 12 to 15 were also interviewed in the study areas. The main outcome measures were quantities and locations of commercial tobacco sources. Between 2005 and 2007 the total number of tobacco sources decreased from 315 to 277 within the study area. Although the most obvious reduction was detected in the number of outdoor vending machines (-48%), the number of indoor vending machines also decreased by 8%. Adolescents changed from vending machines to other sources for cigarettes, particularly kiosks or friends (+31% points usage rate, pvending machines decreased, this has not had a significant impact on cigarette acquisition by underage smokers as they were able to circumvent this new security measure in several different ways.

  15. Numerical Study of Solidification in a Plate Heat Exchange Device with a Zigzag Configuration Containing Multiple Phase-Change-Materials

    Directory of Open Access Journals (Sweden)

    Peilun Wang

    2016-05-01

    Full Text Available Latent heat thermal energy storage (TES plays an important role in the advocation of TES in contrast to sensible energy storage because of the large storage energy densities per unit mass/volume possible at a nearly constant thermal energy. In the current study, a heat exchange device with a zigzag configuration containing multiple phase-change-materials (m-PCMs was considered, and an experimental system was built to validate the model for a single PCM. A two-dimensional numerical model was developed using the ANSYS Fluent 14.0 software program. The energy fractions method was put forward to calculate the average Ste number and the influence of Re and Ste numbers on the discharge process were studied. The influence of phase change temperature among m-PCMs on the solidification process has also been studied. A new boundary condition was defined to determine the combined effect of the Re and Ste numbers on the discharging process. The modelling results show that for a given input power, the Ste (or Re number has a significant impact on the discharging process; however, the period value of inlet velocity has almost no impact on it. Besides, the zigzag plate with m-PCMs has a good impact on the temperature shock as “filter action” in the discharging process.

  16. Device-length changes and implant function following surgical implantation of the KineSpring in cadaver knees

    Directory of Open Access Journals (Sweden)

    McNicholas MJ

    2015-01-01

    Full Text Available Michael J McNicholas,1 Stefan M Gabriel,2 Anton G Clifford,2 Evelyne M Hasler2 1Aintree University Hospital, Teaching Hospital, Major Trauma Centre, NHS Foundation Trust, Liverpool, UK; 2Moximed, Hayward, CA, USA Introduction: The KineSpring implant system has been shown to provide load reductions at the medial compartment of the knee, and has demonstrated clinical success in reducing pain and increasing function in patients with medial knee osteoarthritis. These results depend on the ability of the KineSpring to rotate, lengthen, and shorten to accommodate knee motions, and in response to knee position and loading. Purpose: The present study was undertaken to determine length changes of the implanted KineSpring in response to a range of knee positions, external knee loads, and placements by different orthopedic surgeons. Materials and methods: KineSpring system components were implanted in ten cadaver leg specimens by ten orthopedic surgeons, and absorber-length changes were measured under combined loading and in different positions of the knee. Results and conclusion: Spring compression consistent with knee-load reduction, and device lengthening and shortening to accommodate knee loads and motions were seen. These confirm the functionality of the KineSpring when implanted medially to the knee. Keywords: KineSpring, knee, function, preservation, offloading, osteoarthritis

  17. Angle- and strain-independent coloured free-standing films incorporating non-spherical colloidal photonic crystals.

    Science.gov (United States)

    Yeo, Seon Ju; Tu, Fuquan; Kim, Seung-hyun; Yi, Gi-Ra; Yoo, Pil J; Lee, Daeyeon

    2015-02-28

    Colloidal photonic crystals (CPCs) provide a convenient way to generate structural colour with high stability against degradation under environmental factors. For a number of applications including flexible electronic and energy devices, it is important to generate flexible structural colour that maintains its colour regardless of the angle of observation and the extent of mechanical deformation. However, it is challenging to simultaneously achieve these goals because anisotropy in typical CPC structures (e.g., CPC films) tends to lead to angle-dependent photonic properties and also changes in the lattice constant due to mechanical deformation lead to changes in the photonic properties of CPCs. To overcome these challenges, we present a means of fabricating large-area free-standing films of CPC structures that exhibit angle- and strain-independent photonic characteristics. First, monodisperse double emulsions encapsulating colloidal crystal arrays are prepared using a microfluidic device. By inducing crystallization of highly charged polystyrene particles in the core of double emulsions using osmotic annealing, we generate angle independent colloidal photonic crystal (CPC) supraparticles. Moreover, the shape and crystallinity of the CPC supraparticles can be tuned by changing the concentration of salt in the solution used for osmotic annealing. Subsequently, an array of CPC supraparticles is embedded inside an elastomeric matrix to form a flexible free-standing film, which exhibits structural colours that are independent of viewing angles and externally applied strain.

  18. Uncertainty in T1 mapping using the variable flip angle method with two flip angles

    International Nuclear Information System (INIS)

    Schabel, Matthias C; Morrell, Glen R

    2009-01-01

    Propagation of errors, in conjunction with the theoretical signal equation for spoiled gradient echo pulse sequences, is used to derive a theoretical expression for uncertainty in quantitative variable flip angle T 1 mapping using two flip angles. This expression is then minimized to derive a rigorous expression for optimal flip angles that elucidates a commonly used empirical result. The theoretical expressions for uncertainty and optimal flip angles are combined to derive a lower bound on the achievable uncertainty for a given set of pulse sequence parameters and signal-to-noise ratio (SNR). These results provide a means of quantitatively determining the effect of changing acquisition parameters on T 1 uncertainty. (note)

  19. Research on recognition of ramp angle based on transducer

    Directory of Open Access Journals (Sweden)

    Wenhao GU

    2015-12-01

    Full Text Available Focusing on the recognition of ramp angle, the relationship between the signal of vehicle transducer and real ramp angle is studied. The force change of vehicle on the ramp, and the relationship between the body tilt angle and front and rear suspension scale is discussed. According to the suspension and tire deformation, error angle of the ramp angle is deduced. A mathematical model is established with Matlab/Simulink and used for simulation to generate error curve of ramp angle. The results show that the error angle increases with the increasing of the ramp angle, and the limit value can reach 6.5%, while the identification method can effectively eliminate this error, and enhance the accuracy of ramp angle recognition.

  20. Morphologic features of puncture sites after exoseal vascular closure device implantation: Changes on follow-up computed tomography

    International Nuclear Information System (INIS)

    Ryu, Hwa Seong; Jang, Joo Yeon; Kim, Tae Un; Lee, Jun Woo; Park, Jung Hwan; Choo, Ki Seok; Cho, Mong; Yoon, Ki Tae; Hong, Young Ki; Jeon, Ung Bae

    2017-01-01

    The study aimed to evaluate the morphologic changes in transarterial chemoembolization (TACE) puncture sites implanted with an ExoSeal vascular closure device (VCD) using follow-up computed tomography (CT). 16 patients who used ExoSeal VCD after TACE were enrolled. Using CT images, the diameters and anterior wall thicknesses of the puncture sites in the common femoral artery (CFA) were compared with those of the contralateral CFA before TACE, at 1 month after every TACE session, and at the final follow-up period. The rates of complications were also evaluated. There were no puncture- or VCD-related complications. Follow-up CT images of the CFA's of patients who used ExoSeal VCDs showed eccentric vascular wall thickening with soft-tissue densities considered to be hemostatic plugs. Final follow-up CT images (mean, 616 days; range, 95–1106 days) revealed partial or complete resorption of the hemostatic plugs. The CFA puncture site diameters did not differ statistically from those of the contralateral CFA on the final follow-up CT (p > 0.05), regardless of the number of VCDs used. Follow-up CT images of patients who used ExoSeal VCDs showed no significant vascular stenosis or significant vessel wall thickening

  1. Morphologic features of puncture sites after exoseal vascular closure device implantation: Changes on follow-up computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Hwa Seong; Jang, Joo Yeon; Kim, Tae Un; Lee, Jun Woo; Park, Jung Hwan; Choo, Ki Seok; Cho, Mong; Yoon, Ki Tae; Hong, Young Ki; Jeon, Ung Bae [Pusan National University Yangsan Hospital, Yangsan (Korea, Republic of)

    2017-05-15

    The study aimed to evaluate the morphologic changes in transarterial chemoembolization (TACE) puncture sites implanted with an ExoSeal vascular closure device (VCD) using follow-up computed tomography (CT). 16 patients who used ExoSeal VCD after TACE were enrolled. Using CT images, the diameters and anterior wall thicknesses of the puncture sites in the common femoral artery (CFA) were compared with those of the contralateral CFA before TACE, at 1 month after every TACE session, and at the final follow-up period. The rates of complications were also evaluated. There were no puncture- or VCD-related complications. Follow-up CT images of the CFA's of patients who used ExoSeal VCDs showed eccentric vascular wall thickening with soft-tissue densities considered to be hemostatic plugs. Final follow-up CT images (mean, 616 days; range, 95–1106 days) revealed partial or complete resorption of the hemostatic plugs. The CFA puncture site diameters did not differ statistically from those of the contralateral CFA on the final follow-up CT (p > 0.05), regardless of the number of VCDs used. Follow-up CT images of patients who used ExoSeal VCDs showed no significant vascular stenosis or significant vessel wall thickening.

  2. Insulator-metal transition in substrate-independent VO2 thin film for phase-change devices.

    Science.gov (United States)

    Taha, Mohammad; Walia, Sumeet; Ahmed, Taimur; Headland, Daniel; Withayachumnankul, Withawat; Sriram, Sharath; Bhaskaran, Madhu

    2017-12-20

    Vanadium has 11 oxide phases, with the binary VO 2 presenting stimuli-dependent phase transitions that manifest as switchable electronic and optical features. An elevated temperature induces an insulator-to-metal transition (IMT) as the crystal reorients from a monoclinic state (insulator) to a tetragonal arrangement (metallic). This transition is accompanied by a simultaneous change in optical properties making VO 2 a versatile optoelectronic material. However, its deployment in scalable devices suffers because of the requirement of specialised substrates to retain the functionality of the material. Sensitivity to oxygen concentration and larger-scale VO 2 synthesis have also been standing issues in VO 2 fabrication. Here, we address these major challenges in harnessing the functionality in VO 2 by demonstrating an approach that enables crystalline, switchable VO 2 on any substrate. Glass, silicon, and quartz are used as model platforms to show the effectiveness of the process. Temperature-dependent electrical and optical characterisation is used demonstrating three to four orders of magnitude in resistive switching, >60% chromic discrimination at infrared wavelengths, and terahertz property extraction. This capability will significantly broaden the horizon of applications that have been envisioned but remained unrealised due to the lack of ability to realise VO 2 on any substrate, thereby exploiting its untapped potential.

  3. Left ventricular remodeling and change of systolic function after closure of patent ductus arteriosus in adults: device and surgical closure.

    Science.gov (United States)

    Jeong, Young-Hoon; Yun, Tae-Jin; Song, Jong-Min; Park, Jung-Jun; Seo, Dong-Man; Koh, Jae-Kon; Lee, Se-Whan; Kim, Mi-Jeong; Kang, Duk-Hyun; Song, Jae-Kwan

    2007-09-01

    Left ventricular (LV) remodeling and predictors of LV systolic function late after closure of patent ductus arteriosus (PDA) in adults remain to be clearly demonstrated. In 45 patients with PDA, including 28 patients who received successful occlusion using the Amplatzer device (AD group) (AGA, Golden Valley, MN) and 17 patients who received surgical closure (OP group), echocardiography studies were performed before closure and 1 day (AD group) or within 7 days (OP group) after closure, and then were repeated at > or = 6 months (17 +/- 13 months). In both groups, LV ejection fraction (EF) and end-diastolic volume index were significantly decreased immediately after closure, whereas end-systolic volume index did not change. During the long-term follow-up period, end-systolic as well as end-diastolic volume indices decreased significantly in both groups and LV EF recovered compared to the immediate postclosure state. However, LV EF remained low compared to the preclosure state. Five patients (11.1%) including 3 patients in the AD group and 2 patients in the OP group showed persistent late LV systolic dysfunction (EF or = 62% had a sensitivity of 72% and a specificity of 83% for predicting late normal LV EF after closure. Left ventricular EF remains low late after PDA closure compared with preclosure state in adults. Preclosure LV EF is the best index to predict late postclosure LV EF.

  4. Supersonic flaw detection device for nozzle

    International Nuclear Information System (INIS)

    Hata, Moriki.

    1996-01-01

    In a supersonic flaw detection device to be attached to a body surface of a reactor pressure vessel for automatically detecting flaws of a welded portion of a horizontally connected nozzle by using supersonic waves, a running vehicle automatically running along a circumferential direction of the nozzle comprises a supersonic flaw detection means for detecting flaws of the welded portion of the nozzle by using supersonic waves, and an inclination angle sensor for detecting the inclination angle of the running vehicle relative to the central axis of the nozzle. The running distance of the vehicle running along the circumference of the nozzle, namely, the position of the running vehicle from a reference point of the nozzle can be detected accurately by dividing the distance around the nozzle by the inclination angle detected by the inclination angle sensor. Accordingly, disadvantages in the prior art, for example, that the detected values obtained by using an encoder are changed by slipping or idle running of the magnet wheels are eliminated, and accurate flaw detection can be conducted. In addition, an operation of visually adjusting the reference point for the device can be eliminated. An operator's exposure dose can be reduced. (N.H.)

  5. The quadriceps angle

    DEFF Research Database (Denmark)

    Miles, James Edward; Frederiksen, Jane V.; Jensen, Bente Rona

    2012-01-01

    : Pelvic limbs from red foxes (Vulpes vulpes). METHODS: Q angles were measured on hip dysplasia (HD) and whole limb (WL) view radiographs of each limb between the acetabular rim, mid-point (Q1: patellar center, Q2: femoral trochlea), and tibial tuberosity. Errors of 0.5-2.0 mm at measurement landmarks...

  6. open angle glaucoma (poag)?

    African Journals Online (AJOL)

    there is a build up of pressure due to poor outflow of aqueous humor. The outflow obstruction could occur at the trabecular meshwork of the anterior chamber angle or subsequently in the episcleral vein due to raised venous pressure. Such build up of pressure results in glaucoma . Elevated intraocular pressure remains the ...

  7. The lateral angle revisited

    DEFF Research Database (Denmark)

    Morgan, Jeannie; Lynnerup, Niels; Hoppa, R.D.

    2013-01-01

    measurements taken from computed tomography (CT) scans. Previous reports have observed that the lateral angle size in females is significantly larger than in males. The method was applied to an independent series of 77 postmortem CT scans (42 males, 35 females) to validate its accuracy and reliability...... method appears to be of minimal practical use in forensic anthropology and archeology....

  8. At Right Angles

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 17; Issue 9. At Right Angles. Shailesh A Shirali. Information and Announcements Volume 17 Issue 9 September 2012 pp 920-920. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/017/09/0920-0920 ...

  9. Wide angle isotope separator

    International Nuclear Information System (INIS)

    Kantrowitz, A.

    1976-01-01

    A method and apparatus is described for particle separation. The method uses a wide angle radially expanding vapor of a particle mixture. In particular, selective ionization of one isotope type in the particle mixture is produced in a multichamber separator and the ionized isotope type is accelerated out of the path of the vapor expansion for separate collection

  10. Small-angle reflectometry of milk protein (β -casein) at the air/serum interface and its conformational changes due to fat content and temperature

    International Nuclear Information System (INIS)

    Heidari, R.; White, J.W.

    2003-01-01

    Full text: The surface structure of dispersed emulsions play a key role in stability of the system. Proteins being one of the most important surface-active components in foods stabilise interfaces by self-interaction, resulting in a stiff visco-elastic adsorbed layer. These interactions are sensitive to disruptive effects of lipids. Previous kinetics studies by the group 1 using the X-ray reflectivity method to investigate the surface adsorption of milk proteins indicate that β -casein had a stronger affinity for the air-liquid interface compared to whey proteins. It has been shown that initially a dense protein layer, with the thickness of 20 Angstroms is formed then a second more diffuse layer with lower volume density of protein follows. Here we report the conformational changes (with particular emphasise on the β -casein tail) occurred at the air-milk serum interface due to the effects of milk fat content, temperature and the milk preparation technique (ie homogenisation vs microfluidisation). In the effect of fat content on the adsorption of protein into the interface the key conclusion is that at lower temperatures the surface composition remains unchanged. The compositional changes, however, become significant at room temperature indicating adsorption of less reflective-water-soluble components into the surface layer. Repulsive interactions between casein aggregates are also involved. Microfluidised samples having the advantage of smaller particle size prove to be more stable to fat or temperature effects compared to the corresponding homogenised milks

  11. Interactions of aquatic animals with the ORPC OCGen® in Cobscook Bay, Maine: Monitoring behavior change and assessing the probability of encounter with a deployed MHK device

    Energy Technology Data Exchange (ETDEWEB)

    Zydlewski, Gayle Barbin [Univ. of Maine, Orono, ME (United States). School of Marine Sciences; Staines, Garrett [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Viehman, Haley [Acadia Univ., Wolfville, NS (Canada); Shen, Haixue [Louisiana State Univ., Baton Rouge, LA (United States); Altenritter, Megan [Univ. of Maine, Orono, ME (United States)

    2016-10-19

    Commercial viability of the marine hydrokinetic (MHK) energy industry is contingent on numerous and diverse factors. A major factor is the effects deployed devices have on animals. This factor is multi-faceted since it is dependent on the availability of appropriate scientific approaches to detect these effects. One of the animal groups with overlapping distributions of MHK devices are fishes. As such, individual fish behavior is likely to be influenced by the presence and operation of MHK devices. Depending on the scale of deployment there are implications for changes to essential fish habitat and effects that can be explored during deployment of a single device yet most changes are likely to be realized when multiple devices are deployed over large areas. It is not only important to document these effects and examine the need for mitigation, but also determine whether the methods involved can be used within the economic constraints of this nascent industry. The results presented in this report benefit the MHK industry by providing transferrable environmental monitoring approaches for MHK projects, specifically related to the interactions between static and dynamic tidal turbines and fish. In addition, some of the data can be used to generalize conditions (e.g., the temporal periodicity of fish presence in tidal regions and probability of fish encountering a device) at other MHK sites with similar physical conditions and fish assemblages. Ocean Renewable Power Company, LLC (ORPC) deployed and tested a prototype OCGen® tidal module in Cobscook Bay, Maine, in the summer of 2014. University of Maine researchers proposed an approach to inform other researchers, regulators, and industry members of the effects of this deployment on fish. While the approach was specifically applied to the OCGen® module, results are applicable to other pilot projects and inform future array deployments. Research funded under this grant allowed us to quantify fish presence as well as

  12. Proposed changes to the reimbursement of pharmaceuticals and medical devices in Poland and their impact on market access and the pharmaceutical industry

    Science.gov (United States)

    Badora, Karolina; Caban, Aleksandra; Rémuzat, Cécile; Dussart, Claude; Toumi, Mondher

    2017-01-01

    ABSTRACT In Poland, two proposed amendments to the reimbursement act are currently in preparation; these are likely to substantially change the pricing and reimbursement landscape for both drugs and medical devices. Proposed changes include: alignment of medical device reimbursement with that of pharmaceuticals; relaxing the strict reimbursement criteria for ultra-orphan drugs; establishment of an additional funding category for vaccines; introduction of compassionate use, and a simplified reimbursement pathway for well-established off-label indications; appreciation of manufacturers’ innovation and research and development efforts by creating a dedicated innovation budget; introduction of a mechanism preventing excessive parallel import; prolonged duration of reimbursement decisions and reimbursement lists; and increased flexibility in defining drug programmes. Both amendments are still at a draft stage and many aspects of the new regulations remain unclear. Nonetheless, the overall direction of some of the changes is already evident and warrants discussion due to their high expected impact on pharmaceutical and device manufacturers. Here we evaluate the main changes proposed to the reimbursement of drugs, vaccines, and medical devices, and examine the impact they are likely to have on market access and pharmaceutical industry in Poland. PMID:29081924

  13. Small angle neutron scattering

    International Nuclear Information System (INIS)

    Bernardini, G.; Cherubini, G.; Fioravanti, A.; Olivi, A.

    1976-09-01

    A method for the analysis of the data derived from neutron small angle scattering measurements has been accomplished in the case of homogeneous particles, starting from the basic theory without making any assumption on the form of particle size distribution function. The experimental scattering curves are interpreted with the aid the computer by means of a proper routine. The parameters obtained are compared with the corresponding ones derived from observations at the transmission electron microscope

  14. Determination of solid angle

    International Nuclear Information System (INIS)

    Qiu, S.; Amano, H.; Kasai, A.

    1988-01-01

    The solid angle in extended alpha source measurement for a series of counting geometries has been obtained by two methods: (1) calculated by means of the Nelson Blachmen series; (2) interpolated from the data table given by Gardner. A particular consequence of the application of the Nelson Blachmen series was deduced which was different from that given by the original author. The applicability of these two methods, as well as an experimentally measured method, is also evaluated. (author)

  15. Effect of tungsten on the phase-change properties of Ge_8Sb_2Te_1_1 Thin Films for the Phase-change device

    International Nuclear Information System (INIS)

    Park, Cheol-Jin; Kong, Heon; Lee, Hyun-Yong; Yeo, Jong-Bin

    2017-01-01

    In this study, the electrical, optical, and structural properties of tungsten (W)-doped Ge_8Sb_2Te_1_1 thin films were investigated. Previously, GeSbTe alloys were doped with various materials in an attempt to improve the thermal stability. Ge_8Sb_2Te_1_1 and W-doped Ge_8Sb_2Te_1_1 films with a thickness of 200 nm were fabricated by using an RF magnetron reactive co-sputtering system at room temperature on Si (p-type, 100) and glass substrate. The fabricated thin films were annealed in a furnace in the ∼ 0 - 400 ℃ temperature range. The optical properties were analyzed using a UV-Vis-IR spectrophotometer, and by using Beer’s Law equation, the optical-energy band gap (E_o_p), slope B"1"/"2, and slope 1/F were calculated. For the crystalline materials, an increase in the slope B"1"/"2 and 1/F was observed, exhibiting a good effect on the thermal stability in the amorphous state after the phase change. The structural properties were analyzed by X-ray diffraction, and the result showed that the W-doped Ge_8Sb_2Te_1_1 had a face-centered-cubic (fcc) crystalline structure increased crystallization temperature (T_c). An increase in the T_c increased the thermal stability in the amorphous state. The electrical properties were analyzed using a 4-point probe, exhibiting an increase in the sheet resistance (R_s) in the amorphous and the crystalline states indicating a reduced programming current in the memory device.

  16. Effect of tungsten on the phase-change properties of Ge8Sb2Te11 thin films for the phase-change device

    Science.gov (United States)

    Park, Cheol-Jin; Kong, Heon; Lee, Hyun-Yong; Yeo, Jong-Bin

    2017-07-01

    In this study, the electrical, optical, and structural properties of tungsten (W)-doped Ge8Sb2Te11 thin films were investigated. Previously, GeSbTe alloys were doped with various materials in an attempt to improve the thermal stability. Ge8Sb2Te11 and W-doped Ge8Sb2Te11 films with a thickness of 200 nm were fabricated by using an RF magnetron reactive co-sputtering system at room temperature on Si ( p-type, 100) and glass substrate. The fabricated thin films were annealed in a furnace in the 0 - 400 ° C temperature range. The optical properties were analyzed using a UV-Vis-IR spectrophotometer, and by using Beer's Law equation, the optical-energy band gap ( E op ), slope B 1/2, and slope 1/ F were calculated. For the crystalline materials, an increase in the slope B 1/2 and 1/ F was observed, exhibiting a good effect on the thermal stability in the amorphous state after the phase change. The structural properties were analyzed by X-ray diffraction, and the result showed that the W-doped Ge8Sb2Te11 had a face-centered-cubic (fcc) crystalline structure increased crystallization temperature ( T c ). An increase in the T c increased the thermal stability in the amorphous state. The electrical properties were analyzed using a 4-point probe, exhibiting an increase in the sheet resistance ( R s ) in the amorphous and the crystalline states indicating a reduced programming current in the memory device.

  17. Gonioscopy in primary angle closure glaucoma.

    Science.gov (United States)

    Bruno, Christina A; Alward, Wallace L M

    2002-06-01

    Primary angle closure is a condition characterized by obstruction to aqueous humor outflow by the peripheral iris, and results in changes in the iridocorneal angle that are visible through gonioscopic examination. Gonioscopy in these eyes, however, can be difficult. This chapter discusses techniques that might help in the examination. These include beginning the examination with the inferior angle, methods to help in looking over the iris, cycloplegia, locating the corneal wedge, indentation, van Herick estimation, examining the other eye, and topical glycerin. Finally, there is a discussion about the pathology associated with the closed angle, with emphasis on the appearance of iris bombé, plateau iris, and the distinction between iris processes and peripheral anterior synechiae.

  18. Hong's grading for evaluating anterior chamber angle width.

    Science.gov (United States)

    Kim, Seok Hwan; Kang, Ja Heon; Park, Ki Ho; Hong, Chul

    2012-11-01

    To compare Hong's grading method with anterior segment optical coherence tomography (AS-OCT), gonioscopy, and the dark-room prone-position test (DRPT) for evaluating anterior chamber width. The anterior chamber angle was graded using Hong's grading method, and Hong's angle width was calculated from the arctangent of Hong's grades. The correlation between Hong's angle width and AS-OCT parameters was analyzed. The area under the receiver operating characteristic curve (AUC) for Hong's grading method when discriminating between narrow and open angles as determined by gonioscopy was calculated. Correlation analysis was performed between Hong's angle width and intraocular pressure (IOP) changes determined by DRPT. A total of 60 subjects were enrolled. Of these subjects, 53.5 % had a narrow angle. Hong's angle width correlated significantly with the AS-OCT parameters (r = 0.562-0.719, P < 0.01). A Bland-Altman plot showed relatively good agreement between Hong's angle width and the angle width obtained by AS-OCT. The ability of Hong's grading method to discriminate between open and narrow angles was good (AUC = 0.868, 95 % CI 0.756-0.942). A significant linear correlation was found between Hong's angle width and IOP change determined by DRPT (r = -0.761, P < 0.01). Hong's grading method is useful for detecting narrow angles. Hong's grading correlated well with AS-OCT parameters and DRPT.

  19. The influence of flip angle on the magic angle effect

    International Nuclear Information System (INIS)

    Zurlo, J.V.; Blacksin, M.F.; Karimi, S.

    2000-01-01

    Objective. To assess the impact of flip angle with gradient sequences on the ''magic angle effect''. We characterized the magic angle effect in various gradient echo sequences and compared the signal- to-noise ratios present on these sequences with the signal-to-noise ratios of spin echo sequences.Design. Ten normal healthy volunteers were positioned such that the flexor hallucis longus tendon remained at approximately at 55 to the main magnetic field (the magic angle). The tendon was imaged by a conventional spin echo T1- and T2-weighted techniques and by a series of gradient techniques. Gradient sequences were altered by both TE and flip angle. Signal-to-noise measurements were obtained at segments of the flexor hallucis longus tendon demonstrating the magic angle effect to quantify the artifact. Signal-to-noise measurements were compared and statistical analysis performed. Similar measurements were taken of the anterior tibialis tendon as an internal control.Results and conclusions. We demonstrated the magic angle effect on all the gradient sequences. The intensity of the artifact was affected by both the TE and flip angle. Low TE values and a high flip angle demonstrated the greatest magic angle effect. At TE values less than 30 ms, a high flip angle will markedly increase the magic angle effect. (orig.)

  20. Efficacy and safety of combination therapy with latanoprost after a change in therapeutic regimen from timolol to brinzolamide in Japanese adult patients with primary open-angle glaucoma and ocular hypertension: open, non-randomized 12-week study

    Directory of Open Access Journals (Sweden)

    Shusaku Ishikawa

    2008-09-01

    Full Text Available Shusaku Ishikawa1, Yoshimi Nakamura1, Yuko Nakamura1, Hiroshi Sakai1, Shoichi Sawaguchi1, Kazuo Terashima2, Makoto Kanno2, Hidetoshi Yamashita21Department of Ophthalmology, University of the Ryukyus Faculty of Medicine, Okinawa, Japan; 2Department of Ophthalmology and Visual Science, Yamagata University Faculty of Medicine, Yamagata, JapanPurpose: To compare the efficacy of brinzolamide in Japanese patients with primary open-angle glaucoma (POAG or ocular hypertension (OH after a change from timolol in combination therapy with latanoprost.Methods: A 12-week, prospective, open-label, comparative study was performed in 20 patients [11 males and 9 females, mean age of 64.5 ± 11.0 (SDy] with POAG or OH treated with both latanoprost once daily and timolol 0.5% twice daily. During the study brinzolamide was substituted for timolol. Intraocular pressure (IOP was measured at baseline, 4, 8, and 12 weeks. Blood pressure (BP, pulse rate (PR, and adverse events were also recorded.Results: IOPs at baseline, 4, 8, and 12 weeks were 18.6 ± 2.1 mmHg, 17.8 ± 2.6 mmHg, 17.4 ± 2.5 mmHg, and 17.3 ± 3.5 mmHg, respectively. IOP reduction at 4 and 8 weeks was statistically significant (p < 0.05. The PR was significantly increased at 12 weeks (p < 0.01, but BP was not significantly affected. Four ocular adverse events were noted, but all were mild and transient.Conclusions: Substituting brinzolamide 1% for timolol 0.5% in combination therapy with latanoprost 0.005% demonstrated significant IOP reduction with improvement in PR with POAG or OH. Combination therapy using latanoprost and brinzolamide may be recommended for better IOP control with fewer systemic adverse events.Keywords: open-angle glaucoma, brinzolamide/latanprost combination therapy, timolol/latanoprost combination therapy, intraocular pressure

  1. Nonimaging radiant energy device

    Science.gov (United States)

    Winston, Roland; Ning, Xiaohui

    1993-01-01

    A nonimaging radiant energy device may include a hyperbolically shaped reflective element with a radiant energy inlet and a radiant energy outlet. A convex lens is provided at the radiant energy inlet and a concave lens is provided at the radiant energy outlet. Due to the provision of the lenses and the shape of the walls of the reflective element, the radiant energy incident at the radiant energy inlet within a predetermined angle of acceptance is emitted from the radiant energy outlet exclusively within an acute exit angle. In another embodiment, the radiant energy device may include two interconnected hyperbolically shaped reflective elements with a respective convex lens being provided at each aperture of the device.

  2. Variable angle correlation spectroscopy

    International Nuclear Information System (INIS)

    Lee, Y.K.; Lawrence Berkeley Lab., CA

    1994-05-01

    In this dissertation, a novel nuclear magnetic resonance (NMR) technique, variable angle correlation spectroscopy (VACSY) is described and demonstrated with 13 C nuclei in rapidly rotating samples. These experiments focus on one of the basic problems in solid state NMR: how to extract the wealth of information contained in the anisotropic component of the NMR signal while still maintaining spectral resolution. Analysis of the anisotropic spectral patterns from poly-crystalline systems reveal information concerning molecular structure and dynamics, yet in all but the simplest of systems, the overlap of spectral patterns from chemically distinct sites renders the spectral analysis difficult if not impossible. One solution to this problem is to perform multi-dimensional experiments where the high-resolution, isotropic spectrum in one dimension is correlated with the anisotropic spectral patterns in the other dimensions. The VACSY technique incorporates the angle between the spinner axis and the static magnetic field as an experimental parameter that may be incremented during the course of the experiment to help correlate the isotropic and anisotropic components of the spectrum. The two-dimensional version of the VACSY experiments is used to extract the chemical shift anisotropy tensor values from multi-site organic molecules, study molecular dynamics in the intermediate time regime, and to examine the ordering properties of partially oriented samples. The VACSY technique is then extended to three-dimensional experiments to study slow molecular reorientations in a multi-site polymer system

  3. Real-time monitoring of luminescent lifetime changes of PtOEP oxygen sensing film with LED/photodiode-based time-domain lifetime device.

    Science.gov (United States)

    Ji, Shaomin; Wu, Wanhua; Wu, Yubo; Zhao, Taiyang; Zhou, Fuke; Yang, Yubin; Zhang, Xin; Liang, Xiaofen; Wu, Wenting; Chi, Lina; Wang, Zhonggang; Zhao, Jianzhang

    2009-05-01

    A cost-effective LED/photodiode(PD)-based time-domain luminescent lifetime measuring device with rugged electronics and simplified algorithms was assembled and successfully used to characterize oxygen sensing films, by continuously monitoring phosphorescence lifetime changes of phosphorescent platinum octaethylporphyrin (PtOEP) in cardo poly(aryl ether ketone) polymer (IMPEK-C) vs. variation of the oxygen partial pressure in a gas mixture (O(2)/N(2)). The results determined by both phosphorescence lifetime and intensity monitoring were compared and the lifetime mode gave results which are in good agreement with the intensity mode. The lifetime-based linear Stern-Volmer plot indicates that the PtOEP molecules are nearly homogeneously distributed in the sensing film. The phosphorescent lifetime of the PtOEP film changes from 75 micros in neat N(2) to less than 2 micros in neat O(2). The sensing system (by combination of the PtOEP sensing film with the home-assembled lifetime device) gives a high lifetime-based O(2) sensing resolution, e.g. about 2 micros Torr(-1) for low O(2) concentration (below 3.5% O(2), V/V). This feasible lifetime device configuration is affordable to most sensor laboratories and the device may facilitate the study of O(2) sensing material with the continuous lifetime monitoring method.

  4. Effect of laser peripheral iridotomy on anterior chamber angle anatomy in primary angle closure spectrum eyes

    Science.gov (United States)

    Kansara, Seema; Blieden, Lauren S.; Chuang, Alice Z.; Baker, Laura A.; Bell, Nicholas P.; Mankiewicz, Kimberly A.; Feldman, Robert M.

    2015-01-01

    Purpose To evaluate the change in trabecular-iris circumference volume (TICV) after laser peripheral iridotomy (LPI) in primary angle closure (PAC) spectrum eyes Patients and Methods Forty-two chronic PAC spectrum eyes from 24 patients were enrolled. Eyes with anterior chamber abnormalities affecting angle measurement were excluded. Intraocular pressure, slit lamp exam, and gonioscopy were recorded at each visit. Anterior segment optical coherence tomography (ASOCT) with 3D mode angle analysis scans were taken with the CASIA SS-1000 (Tomey Corp., Nagoya, Japan) before and after LPI. Forty-two pre-LPI ASOCT scans and 34 post-LPI ASOCT scans were analyzed using the Anterior Chamber Analysis and Interpretation (ACAI, Houston, TX) software. A mixed-effect model analysis was used to compare the trabecular-iris space area (TISA) changes among 4 quadrants, as well as to identify potential factors affecting TICV. Results There was a significant increase in all average angle parameters after LPI (TISA500, TISA750, TICV500, and TICV750). The magnitude of change in TISA500 in the superior angle was significantly less than the other angles. The changes in TICV500 and TICV750 were not associated with any demographic or ocular characteristics. Conclusion TICV is a useful parameter to quantitatively measure the effectiveness of LPI in the treatment of eyes with PAC spectrum disease. PMID:26066504

  5. Angle-averaged Compton cross sections

    International Nuclear Information System (INIS)

    Nickel, G.H.

    1983-01-01

    The scattering of a photon by an individual free electron is characterized by six quantities: α = initial photon energy in units of m 0 c 2 ; α/sub s/ = scattered photon energy in units of m 0 c 2 ; β = initial electron velocity in units of c; phi = angle between photon direction and electron direction in the laboratory frame (LF); theta = polar angle change due to Compton scattering, measured in the electron rest frame (ERF); and tau = azimuthal angle change in the ERF. We present an analytic expression for the average of the Compton cross section over phi, theta, and tau. The lowest order approximation to this equation is reasonably accurate for photons and electrons with energies of many keV

  6. Angle-averaged Compton cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Nickel, G.H.

    1983-01-01

    The scattering of a photon by an individual free electron is characterized by six quantities: ..cap alpha.. = initial photon energy in units of m/sub 0/c/sup 2/; ..cap alpha../sub s/ = scattered photon energy in units of m/sub 0/c/sup 2/; ..beta.. = initial electron velocity in units of c; phi = angle between photon direction and electron direction in the laboratory frame (LF); theta = polar angle change due to Compton scattering, measured in the electron rest frame (ERF); and tau = azimuthal angle change in the ERF. We present an analytic expression for the average of the Compton cross section over phi, theta, and tau. The lowest order approximation to this equation is reasonably accurate for photons and electrons with energies of many keV.

  7. Structural changes of electron and ion beam-deposited contacts in annealed carbon-based electrical devices

    KAUST Repository

    Batra, Nitin M; Patole, Shashikant P.; Abdelkader, Ahmed; Anjum, Dalaver H.; Deepak, Francis L; Da Costa, Pedro M. F. J.

    2015-01-01

    The use of electron and ion beam deposition to make devices containing discrete nanostructures as interconnectors is a well-known nanofabrication process. Classically, one-dimensional materials such as carbon nanotubes (CNTs) have been electrically characterized by resorting to these beam deposition methods. While much attention has been given to the interconnectors, less is known about the contacting electrodes (or leads). In particular, the structure and chemistry of the electrode–interconnector interface is a topic that deserves more attention, as it is critical to understand the device behavior. Here, the structure and chemistry of Pt electrodes, deposited either with electron or ion beams and contacted to a CNT, are analyzed before and after thermally annealing the device in a vacuum. Free-standing Pt nanorods, acting as beam-deposited electrode models, are also characterized pre- and post-annealing. Overall, the as-deposited leads contain a non-negligible amount of amorphous carbon that is consolidated, upon heating, as a partially graphitized outer shell enveloping a Pt core. This observation raises pertinent questions regarding the definition of electrode–nanostructure interfaces in electrical devices, in particular long-standing assumptions of metal-CNT contacts fabricated by direct beam deposition methods.

  8. Structural changes of electron and ion beam-deposited contacts in annealed carbon-based electrical devices

    KAUST Repository

    Batra, Nitin M

    2015-10-09

    The use of electron and ion beam deposition to make devices containing discrete nanostructures as interconnectors is a well-known nanofabrication process. Classically, one-dimensional materials such as carbon nanotubes (CNTs) have been electrically characterized by resorting to these beam deposition methods. While much attention has been given to the interconnectors, less is known about the contacting electrodes (or leads). In particular, the structure and chemistry of the electrode–interconnector interface is a topic that deserves more attention, as it is critical to understand the device behavior. Here, the structure and chemistry of Pt electrodes, deposited either with electron or ion beams and contacted to a CNT, are analyzed before and after thermally annealing the device in a vacuum. Free-standing Pt nanorods, acting as beam-deposited electrode models, are also characterized pre- and post-annealing. Overall, the as-deposited leads contain a non-negligible amount of amorphous carbon that is consolidated, upon heating, as a partially graphitized outer shell enveloping a Pt core. This observation raises pertinent questions regarding the definition of electrode–nanostructure interfaces in electrical devices, in particular long-standing assumptions of metal-CNT contacts fabricated by direct beam deposition methods.

  9. Structural changes of electron and ion beam-deposited contacts in annealed carbon-based electrical devices.

    Science.gov (United States)

    Batra, Nitin M; Patole, Shashikant P; Abdelkader, Ahmed; Anjum, Dalaver H; Deepak, Francis L; Costa, Pedro M F J

    2015-11-06

    The use of electron and ion beam deposition to make devices containing discrete nanostructures as interconnectors is a well-known nanofabrication process. Classically, one-dimensional materials such as carbon nanotubes (CNTs) have been electrically characterized by resorting to these beam deposition methods. While much attention has been given to the interconnectors, less is known about the contacting electrodes (or leads). In particular, the structure and chemistry of the electrode-interconnector interface is a topic that deserves more attention, as it is critical to understand the device behavior. Here, the structure and chemistry of Pt electrodes, deposited either with electron or ion beams and contacted to a CNT, are analyzed before and after thermally annealing the device in a vacuum. Free-standing Pt nanorods, acting as beam-deposited electrode models, are also characterized pre- and post-annealing. Overall, the as-deposited leads contain a non-negligible amount of amorphous carbon that is consolidated, upon heating, as a partially graphitized outer shell enveloping a Pt core. This observation raises pertinent questions regarding the definition of electrode-nanostructure interfaces in electrical devices, in particular long-standing assumptions of metal-CNT contacts fabricated by direct beam deposition methods.

  10. Myocardial changes in patients with end-stage heart failure during continuous flow left ventricular assist device support

    NARCIS (Netherlands)

    Lok, S.I.

    2013-01-01

    With respect to the clinical outcome, cf-LVADs provide sufficient ventricular unloading and circulatory support. The post-operative mortality and morbidity in our centre are comparable with other recent experiences with this device. Based on these data, Heart Mate II (HM II) LVAD therapy can be

  11. Qualitative Assessment of an Electronic Activity-Tracking Device: Strengths, Weaknesses, and Considerations in Behavior Change Interventions for Health Educators

    Science.gov (United States)

    Ball, James W.; Bice, Matthew R.; Adkins, Megan M.

    2015-01-01

    Motivating people to engage in regular physical activity (PA) is a constant struggle for many health education professionals. The purchase of activity-tracking devices (Fitbit, Nike Fuel Band, etc…) has been a popular trend in recent years, presumably to assist users to increase their PA. However, limited research has examined consumer feedback…

  12. Temperature indicating device

    International Nuclear Information System (INIS)

    Angus, J.P.; Salt, D.

    1988-01-01

    A temperature indicating device comprises a plurality of planar elements some undergoing a reversible change in appearance at a given temperature the remainder undergoing an irreversible change in appearance at a given temperature. The device is useful in indicating the temperature which an object has achieved as well as its actual temperature. The reversible change is produced by liquid crystal devices. The irreversible change is produced by an absorbent surface carrying substances e.g. waxes which melt at predetermined temperatures and are absorbed by the surface; alternatively paints may be used. The device is used for monitoring processes of encapsulation of radio active waste. (author)

  13. Evaluation of touch-sensitive screen tablet terminal button size and spacing accounting for effect of fingertip contact angle.

    Science.gov (United States)

    Nishimura, T; Doi, K; Fujimoto, H

    2015-08-01

    Touch-sensitive screen terminals enabling intuitive operation are used as input interfaces in a wide range of fields. Tablet terminals are one of the most common devices with a touch-sensitive screen. They have a feature of good portability, enabling use under various conditions. On the other hand, they require a GUI designed to prevent decrease of usability under various conditions. For example, the angle of fingertip contact with the display changes according to finger posture during operation and how the case is held. When a human fingertip makes contact with an object, the contact area between the fingertip and contact object increases or decreases as the contact angle changes. A touch-sensitive screen detects positions using the change in capacitance of the area touched by the fingertip; hence, differences in contact area between the touch-sensitive screen and fingertip resulting from different forefinger angles during operation could possibly affect operability. However, this effect has never been studied. We therefore conducted an experiment to investigate the relationship between size/spacing and operability, while taking the effect of fingertip contact angle into account. As a result, we have been able to specify the button size and spacing conditions that enable accurate and fast operation regardless of the forefinger contact angle.

  14. CDC field mapping device - ''ROTOTRACK''

    International Nuclear Information System (INIS)

    Yamada, R.; Hawtree, J.; Kaczar, K.; Leverence, R.; McGuire, K.; Newman-Holmes, C.; Schmidt, E.E.; Shallenberger, J.

    1985-10-01

    A field mapping device for the magnet of the Collider Detector at Fermilab (CDF) was constructed. The device was used for extensive study of the CDF magnetic field distribution. The mechanical and electrical features of the device, as well as the data acquisition system and software, are described. The mechanical system was designed so that the errors on the position and angle of the probe were +-0.75 mm and +-1 mrad, respectively

  15. Equilibrium contact angle or the most-stable contact angle?

    Science.gov (United States)

    Montes Ruiz-Cabello, F J; Rodríguez-Valverde, M A; Cabrerizo-Vílchez, M A

    2014-04-01

    It is well-established that the equilibrium contact angle in a thermodynamic framework is an "unattainable" contact angle. Instead, the most-stable contact angle obtained from mechanical stimuli of the system is indeed experimentally accessible. Monitoring the susceptibility of a sessile drop to a mechanical stimulus enables to identify the most stable drop configuration within the practical range of contact angle hysteresis. Two different stimuli may be used with sessile drops: mechanical vibration and tilting. The most stable drop against vibration should reveal the changeless contact angle but against the gravity force, it should reveal the highest resistance to slide down. After the corresponding mechanical stimulus, once the excited drop configuration is examined, the focus will be on the contact angle of the initial drop configuration. This methodology needs to map significantly the static drop configurations with different stable contact angles. The most-stable contact angle, together with the advancing and receding contact angles, completes the description of physically realizable configurations of a solid-liquid system. Since the most-stable contact angle is energetically significant, it may be used in the Wenzel, Cassie or Cassie-Baxter equations accordingly or for the surface energy evaluation. © 2013 Elsevier B.V. All rights reserved.

  16. Electromagnetic brake/clutch device

    Science.gov (United States)

    Vranish, John M. (Inventor)

    1994-01-01

    An electromagnetic brake/clutch device includes a drive shaft supported by at least one bearing for transmitting torque, a housing, affixed to prevent its rotation, surrounding the drive shaft, and an electromagnetically activated device within the housing to selectively prevent and allow rotation of the drive shaft. The electromagnetically activated device includes a plurality of cammed rollers to prevent counter-clockwise rotation of the drive shaft. The drive shaft includes a circumferential disk and the housing includes a reaction ring for engagement with the plurality of cammed rollers. The plurality of cammed rollers are released from engagement with the circumferential disk and the reaction ring by a plurality of tripping mechanisms within the housing. The tripping action uses the locking force to act as a release force merely by changing the boundary conditions of the roller interface angles. The tripping mechanisms include trippers for disengaging the plurality of cammed rollers and an anvil shaped portion for providing lateral movement of the trippers. The plurality of cammed rollers is preloaded to engagement with the circumferential disk and reaction ring by a spring, and is located with respect to an adjacent tripping mechanism with another spring.

  17. Integrated health outcomes research strategies in drug or medical device development, pre- and postmarketing: time for change.

    Science.gov (United States)

    Badía, Xavier; Guyver, Alice; Magaz, Sol; Bigorra, Juan

    2002-06-01

    The implementation of health outcomes research as a healthcare decision-making tool has expanded rapidly in the last decade. Drugs and medical devices are increasingly being required to demonstrate not only their efficacy and safety characteristics, but also their performance in at least three core dimensions of health outcomes research: clinical effectiveness, patient-reported outcomes and economic outcomes. However, the current integration of health outcomes research lacks coordination and communication and as a result, money and time is being spent on the generation of health outcomes research data which can be both insufficient and fail to satisfy the information demands of all the relevant stakeholders. In response to this, a new paradigm is evolving which involves the implementation of health outcomes research strategies that encompass the development, pre- and postmarketing stages of a drug or medical device.

  18. Evanescent-wave coupled right angled buried waveguide: Applications in carbon nanotube mode-locking

    International Nuclear Information System (INIS)

    Mary, R.; Thomson, R. R.; Kar, A. K.; Brown, G.; Beecher, S. J.; Popa, D.; Sun, Z.; Torrisi, F.; Hasan, T.; Milana, S.; Bonaccorso, F.; Ferrari, A. C.

    2013-01-01

    We present an evanescent-field device based on a right-angled waveguide. This consists of orthogonal waveguides, with their points of intersection lying along an angled facet of the chip. Light guided along one waveguide is incident at the angled dielectric-air facet at an angle exceeding the critical angle, so that the totally internally reflected light is coupled into the second waveguide. By depositing a nanotube film on the angled surface, the chip is then used to mode-lock an Erbium doped fiber ring laser with a repetition rate of 26 MHz, and pulse duration of 800 fs

  19. Skeletal and soft tissue changes and stability in cleft lip and palate patients after distraction osteogenesis using a new intraoral maxillary device.

    Science.gov (United States)

    Ansari, Edward; Tomat, Catherine; Kadlub, Natacha; Diner, Patrick A; Bellocq, Thomas; Vazquez, Marie-Paule; Picard, Arnaud

    2015-04-01

    The authors have recently reported on the use of an internal maxillary distraction device. In this study, we report on the hard and soft tissue movements achieved with this intraoral distraction device, and the stability changes after distraction osteogenesis for maxillary hypoplasia in patients with cleft lip and palate. Ten male patients with severe hypoplasia of the maxilla, with complete uni- or bilateral cleft lip and palate were included. The mean age of the patients at the time of operation was 11.91 years (±3.41). To evaluate the distraction process and stability, superimpositions on the preoperative lateral cephalograms were performed. The mean follow-up (FU) was 15.42 months (±3.94). Cephalometric measurements at all of the maxillary hard and soft tissue points improved significantly. Maxillary point A was advanced by 8.25 mm (±3.17; P distraction soft tissue point A' had advanced 7.10 mm (±2.69; P distraction. Maxillary horizontal relapse at point A was 14.1% at FU. Vertical relapse was not significant. This rigid intraoral distraction device can be successfully used in the correction of severe maxillary hypoplasia. The marked aesthetic improvement and low psychological encumbrance make this device viable for the treatment of cleft-related hypoplasia of the maxilla. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  20. Variation in emission and energy recovery concerning incident angle in a scheme recovering high energy ions by secondary electrons

    International Nuclear Information System (INIS)

    Wada, Takayuki; Konno, Shota; Nakamoto, Satoshi; Takeno, Hiromasa; Furuyama, Yuichi; Taniike, Akira

    2016-01-01

    As an energy recovery device for fast protons produced in D- 3 He nuclear fusion, secondary electron (SE) direct energy converter (SEDEC) was proposed in addition to traveling wave direct energy converter (TWDEC). Some protons passing through a TWDEC come into an SEDEC, where protons penetrate to a number of foil electrodes and emitted SEs are recovered. Following to a development of SE orbit control by magnetic field, dependence on incident angle of protons was examined to optimize structure of SEDEC. Based on a theoretical expectation, experiments were performed by changing incident angle of protons and variation in emission and energy recovery were measured. Both emission and energy recovery increased as the angle increased, and differences with theoretical expectation are discussed. (author)

  1. Predicting Peri-Device Leakage of Left Atrial Appendage Device Closure Using Novel Three-Dimensional Geometric CT Analysis.

    Science.gov (United States)

    Chung, Hyemoon; Jeon, Byunghwan; Chang, Hyuk-Jae; Han, Dongjin; Shim, Hackjoon; Cho, In Jeong; Shim, Chi Young; Hong, Geu-Ru; Kim, Jung-Sun; Jang, Yangsoo; Chung, Namsik

    2015-12-01

    After left atrial appendage (LAA) device closure, peri-device leakage into the LAA persists due to incomplete occlusion. We hypothesized that pre-procedural three-dimensional (3D) geometric analysis of the interatrial septum (IAS) and LAA orifice can predict this leakage. We investigated the predictive parameters of LAA device closure obtained from baseline cardiac computerized tomography (CT) using a novel 3D analysis system. We conducted a retrospective study of 22 patients who underwent LAA device closure. We defined peri-device leakage as the presence of a Doppler signal inside the LAA after device deployment (group 2, n = 5) compared with patients without peri-device leakage (group 1, n = 17). Conventional parameters were measured by cardiac CT. Angles θ and φ were defined between the IAS plane and the line, linking the LAA orifice center and foramen ovale. Group 2 exhibited significantly better left atrial (LA) function than group 1 (p = 0.031). Pre-procedural θ was also larger in this group (41.9° vs. 52.3°, p = 0.019). The LAA cauliflower-type morphology was more common in group 2. Overall, the patients' LA reserve significantly decreased after the procedure (21.7 mm(3) vs. 17.8 mm(3), p = 0.035). However, we observed no significant interval changes in pre- and post-procedural values of θ and φ in either group (all p > 0.05). Angles between the IAS and LAA orifice might be a novel anatomical parameter for predicting peri-device leakage after LAA device closure. In addition, 3D CT analysis of the LA and LAA orifice could be used to identify clinically favorable candidates for LAA device closure.

  2. Innovative energy absorbing devices based on composite tubes

    Science.gov (United States)

    Tiwari, Chandrashekhar

    Analytical and experimental study of innovative load limiting and energy absorbing devices are presented here. The devices are based on composite tubes and can be categorized in to two groups based upon the energy absorbing mechanisms exhibited by them, namely: foam crushing and foam fracturing. The device based on foam crushing as the energy absorbing mechanism is composed of light weight elastic-plastic foam filling inside an angle ply composite tube. The tube is tailored to have a high Poisson’s ratio (>20). Upon being loaded the device experiences large transverse contraction resulting in rapid decrease in diameter. At a certain axial load the foam core begins to crush and energy is dissipated. This device is termed as crush tube device. The device based upon foam shear fracture as the energy absorbing mechanism involves an elastic-plastic core foam in annulus of two concentric extension-twist coupled composite tubes with opposite angles of fibers. The core foam is bonded to the inner and outer tube walls. Upon being loaded axially, the tubes twist in opposite directions and fracture the core foam in out of plane shear and thus dissipate the energy stored. The device is termed as sandwich core device (SCD). The devices exhibit variations in force-displacement characteristics with changes in design and material parameters, resulting in wide range of energy absorption capabilities. A flexible matrix composite system was selected, which was composed of high stiffness carbon fibers as reinforcements in relatively low stiffness polyurethane matrix, based upon large strain to failure capabilities and large beneficial elastic couplings. Linear and non-linear analytical models were developed encapsulating large deformation theory of the laminated composite shells (using non-linear strain energy formulation) to the fracture mechanics of core foam and elastic-plastic deformation theory of the foam filling. The non-linear model is capable of including material and

  3. Analyzing the installation angle error of a SAW torque sensor

    International Nuclear Information System (INIS)

    Fan, Yanping; Ji, Xiaojun; Cai, Ping

    2014-01-01

    When a torque is applied to a shaft, normal strain oriented at ±45° direction to the shaft axis is at its maximum, which requires two one-port SAW resonators to be bonded to the shaft at ±45° to the shaft axis. In order to make the SAW torque sensitivity high enough, the installation angle error of two SAW resonators must be confined within ±5° according to our design requirement. However, there are few studies devoted to the installation angle analysis of a SAW torque sensor presently and the angle error was usually obtained by a manual method. Hence, we propose an approximation method to analyze the angle error. First, according to the sensitive mechanism of the SAW device to torque, the SAW torque sensitivity is deduced based on the linear piezoelectric constitutive equation and the perturbation theory. Then, when a torque is applied to the tested shaft, the stress condition of two SAW resonators mounted with an angle deviating from ±45° to the shaft axis, is analyzed. The angle error is obtained by means of the torque sensitivities of two orthogonal SAW resonators. Finally, the torque measurement system is constructed and the loading and unloading experiments are performed twice. The torque sensitivities of two SAW resonators are obtained by applying average and least square method to the experimental results. Based on the derived angle error estimation function, the angle error is estimated about 3.447°, which is close to the actual angle error 2.915°. The difference between the estimated angle and the actual angle is discussed. The validity of the proposed angle error analysis method is testified to by the experimental results. (technical design note)

  4. Changes after surgically-assisted maxillary expansion (SARME) to the dentoalveolar, palatal and nasal structures by using tooth-borne distraction devices.

    Science.gov (United States)

    Seeberger, Robin; Kater, Wolfgang; Schulte-Geers, Michael; Davids, Rolf; Freier, Kolja; Thiele, Oliver

    2011-07-01

    Different devices are available to aid surgically-assisted maxillary expansion. In this study we have evaluated the changes to the anchoring teeth, the hard palate, and the lower nasal passage made by tooth-borne distraction devices. Thirty-one patients (mean (SD) age 28 (2) years) with deficiencies in the transverse width of the maxilla were examined by computed tomography and cone beam scans before and after operation. The data were analysed with the help of Wilcoxon's signed rank test and Spearman's r correlation. The mean (SD) distraction width was 6.5 (2.3) mm. All anchorage teeth were tilted (pdistraction width, with changes in the intercoronal and interapical distances of the anchoring premolars (pdistraction width and the overall gain in width of the lower nasal passage (pmaxillary expansion with tooth-borne devices has significant effects on the anchoring teeth, the nasal floor, and the hard palate. Both tilting of the teeth and an evenly distributed movement of the segments were seen. Copyright © 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  5. A comparison of the sensitivity of EQ-5D, SF-6D and TTO utility values to changes in vision and perceived visual function in patients with primary open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Bozzani Fiammetta Maria

    2012-08-01

    Full Text Available Abstract Background Economic viability of treatments for primary open-angle glaucoma (POAG should be assessed objectively to prioritise health care interventions. This study aims to identify the methods for eliciting utility values (UVs most sensitive to differences in visual field and visual functioning in patients with POAG. As a secondary objective, the dimensions of generic health-related and vision-related quality of life most affected by progressive vision loss will be identified. Methods A total of 132 POAG patients were recruited. Three sets of utility values (EuroQoL EQ-5D, Short Form SF-6D, Time Trade Off and a measure of perceived visual functioning from the National Eye Institute Visual Function Questionnaire (VFQ-25 were elicited during face-to-face interviews. The sensitivity of UVs to differences in the binocular visual field, visual acuity and visual functioning measures was analysed using non-parametric statistical methods. Results Median utilities were similar across Integrated Visual Field score quartiles for EQ-5D (P = 0.08 whereas SF-6D and Time-Trade-Off UVs significantly decreased (p = 0.01 and p = 0.001, respectively. The VFQ-25 score varied across Integrated Visual Field and binocular visual acuity groups and was associated with all three UVs (P ≤ 0.001; most of its vision-specific sub-scales were associated with the vision markers. The most affected dimension was driving. A relationship with vision markers was found for the physical component of SF-36 and not for any dimension of EQ-5D. Conclusions The Time-Trade-Off was more sensitive than EQ-5D and SF-6D to changes in vision and visual functioning associated with glaucoma progression but could not measure quality of life changes in the mildest disease stages.

  6. Early intraocular pressure change after peripheral iridotomy with ultralow fluence pattern scanning laser and Nd:YAG laser in primary angle-closure suspect: Kowloon East Pattern Scanning Laser Study Report No. 3.

    Science.gov (United States)

    Chan, Jeffrey Chi Wang; Choy, Bonnie Nga Kwan; Chan, Orlando Chia Chieh; Li, Kenneth Kai Wang

    2018-02-01

    Our purpose was to assess the early intraocular pressure (IOP) changes of ultralow fluence laser iridotomy using pattern scanning laser followed by neodymium:yttrium-aluminum-gamet (Nd:YAG) laser. This is a prospective interventional study. Thirty-three eyes of 33 adult Chinese primary angle-closure suspect subjects were recruited for prophylactic laser peripheral iridotomy. Sequential laser peripheral iridotomy was performed using pattern scanning laser followed by Nd:YAG laser. Visual acuity (VA) and IOP were measured before treatment, at 1 h, 1 day, 1 week, 1 month, 3 months and 6 months after laser. Laser energy used and complications were documented. Corneal endothelial cell count was examined at baseline and 6 months. Patency of the iridotomy was assessed at each follow-up visit. All subjects achieved patent iridotomy in a single session. The mean energy used was 0.335+/-0.088 J for the pattern scanning laser, and 4.767+/-5.780 mJ for the Nd:YAG laser. The total mean energy was 0.339+/-0.089 J. None of the eyes developed a clinically significant IOP spike (≥ 8 mmHg) at 1 h and 1 day after laser use. Only four eyes developed higher IOP at 1 h and all were ≤3 mmHg compared to baseline. The mean IOP was 13.8+/-2.5 mmHg at 1 h and 11.5+/-2.2 mmHg at 1 day, both were significantly lower than baseline (15.8+/-2.1 mmHg) (P laser compared to baseline (0.23 vs 0.26). There was also no statistically significant difference in mean VA at other follow-up visits compared to baseline. Peripheral iridotomy closure was encountered in two (6.1%) eyes, one at 1 month and another at 6 months follow-up. There were no complications including hyphema, peripheral anterior synechia formation nor prolonged inflammation throughout the follow-up period. There was no significant loss in corneal endothelial cell counts at 6 months (2255+/-490) compared to baseline (2303+/-386) (P = 0.347). Sequential LPI using an ultralow fluence pattern scanning laser

  7. Persistent weight loss with a non-invasive novel medical device to change eating behaviour in obese individuals with high-risk cardiovascular risk profile.

    Directory of Open Access Journals (Sweden)

    Peter von Seck

    Full Text Available In evidence-based weight-loss programs weight regain is common after an initial weight reduction. Eating slowly significantly lowers meal energy intake and hunger ratings. Despite this knowledge, obese individuals do not implement this behaviour. We, thus tested the hypothesis of changing eating behaviour with an intra-oral medical device leading to constant weight reduction in overweight and obesity. Six obese patients (6 men, age 56 ± 14, BMI 29 ± 2 kg / m2 with increased CVRF profile were included in this prospective study. All patients had been treated for obesity during the last 10 years in a single centre and had at least 3 frustrate evidence-based diets. Patients received a novel non-invasive intra-oral medical device to slow eating time. Further advice included not to count calories, to avoid any other form of diet, to take their time with their meals, and to eat whatever they liked. This device was used only during meals for the first 4 to 8 weeks for a total of 88 [20-160] hours. Follow-up period was 23 [15-38] months. During this period, patients lost 11% [5-20%] (p5%, and 67% (4/6 achieved a >10% bodyweight loss. In the course of the study, altered eating patterns were observed. There were no complications with the medical device. Of note, all patients continued to lose weight after the initial intervention period (p<0.001 and none of them had weight regain. With this medical device, overweight and obese patients with a history of previously frustrating attempts to lose weight achieved a significant and sustained weight loss over two years. These results warrant the ongoing prospective randomised controlled trial to prove concept and mechanism of action.German Clinical Trials Register DRKS00011357.

  8. The double Brewster angle effect

    Science.gov (United States)

    Thirion-Lefevre, Laetitia; Guinvarc'h, Régis

    2018-01-01

    The Double Brewster angle effect (DBE) is an extension of the Brewster angle to double reflection on two orthogonal dielectric surfaces. It results from the combination of two pseudo-Brewster angles occurring in complementary incidence angles domains. It can be observed for a large range of incidence angles provided that double bounces mechanism is present. As a consequence of this effect, we show that the reflection coefficient at VV polarization can be at least 10 dB lower than the reflection coefficient at HH polarization over a wide range of incidence angle - typically from 20 to 70∘. It is experimentally demonstrated using a Synthetic Aperture Radar (SAR) image that this effect can be seen on buildings and forests. For large buildings, the difference can reach more than 20 dB. xml:lang="fr"

  9. A device for measuring electron beam characteristics

    Directory of Open Access Journals (Sweden)

    M. Andreev

    2017-01-01

    Full Text Available This paper presents a device intended for diagnostics of electron beams and the results obtained with this device. The device comprises a rotating double probe operating in conjunction with an automated probe signal collection and processing system. This provides for measuring and estimating the electron beam characteristics such as radius, current density, power density, convergence angle, and brightness.

  10. Physical characteristics comparison of virtual wedge device with physical wedge

    International Nuclear Information System (INIS)

    Cho, Jung Keun; Choi, Kye Sook; Lim, Cheong Hwan; Kim, Jeong Koo; Jung, Hong Ryang; Lee, Jung Ok; Lee, Man Goo

    2001-01-01

    We compared the characteristics of Siemens virtual wedge device with physical wedges for clinical application. We investigated the characteristics of virtual and physical wedges for various wedge angles (15, 30, 45, and 60) using 6- and 15- MV photon beams. Wedge factors were measured in water using an ion chamber for various field sizes and depths. In case of virtual wedge device, as upper jaw moves during irradiation, wedge angles were estimated by accumulated doses. These measurements were performed at off-axis points perpendicular to the beam central axis in water for a 15 cm x 20 cm radiation field size at the depth of 10 cm. Surface does without and with virtual or physical wedges were measured using a parallel plate ion chamber at surface. Field size was 15 cm * 20 cm and a polystyrene phantom was used. For various field sizes, virtual and physical wedge factors were changed by maximum 2.1% and 3.9%, respectively. For various depths, virtual and physical wedge factors were changed by maximum 1.9% and 2.9%, respectively. No major difference was found between the virtual and physical wedge angles and the difference was within 0.5. Surface dose with physical wedge was reduced by maximum 20% (x-ray beam : 6 MV, wedge angle : 45, SSD : 80 cm) relative to one with virtual wedge or without wedge. Comparison of the characteristics of Siemens virtual wedge device with physical wedges was performed. Depth dependence of virtual wedge factor was smaller than that of physical wedge factor. Virtual and physical wedge factors were nearly independent of field sizes. The accuracy of virtual and physical wedge angles was excellent. Surface dose was found to be reduced using a physical wedge

  11. Physical characteristics comparison of virtual wedge device with physical wedge

    International Nuclear Information System (INIS)

    Choi, Dong Rak; Shin, Kyung Hwan; Lee, Kyu Chan; Kim, Dae Yong; Ahn, Yong Chan; Lim, Do Hoon; Kim, Moon Kyung; Huh, Seung Jae

    1999-01-01

    We have compared the characteristics of Siemens virtual wedge device with physical wedges for clinical application. We investigated the characteristics of virtual and physical wedges for various wedge angles (15, 30, 45, and 60 ) using 6- and 15MV photon beams. Wedge factors were measured in water using an ion chamber for various field sizes and depths. In case of virtual wedge device, as upper jaw moves during irradiation, wedge angles were estimated by accumulated doses. These measurements were performed at off-axis points perpendicular to the beam central axis in water for a 15 cm x 20 cm radiation field size at the depth of 10 cm. Surface doses without and with virtual or physical wedges were measured using a parallel plate ion chamber at surface. Field size was 15 cm x 20 cm and a polystyrene phantom was used. For various field sizes, virtual and physical wedge factors were changed by maximum 2.1% and 3.9%, respectively. For various depths, virtual and physical wedge factors were changed by maximum 1.9% and 2.9%, respectively. No major difference was found between the virtual and physical wedge angles and the difference was within 0.5 .deg. . Surface dose with physical wedge was reduced by maximum 20% (x-ray beam: 6 MV, wedge angle: 45 .deg. , SSD: 80cm) relative to one with virtual wedge or without wedge. Comparison of the characteristics of Siemens virtual wedge device with physical wedges was performed. Depth dependence of virtual wedge factor was smaller than that of physical wedge factor. Virtual and physical wedge factors were nearly independent of field sizes. The accuracy of virtual and physical wedge angles was excellent. Surface dose was found to be reduced using physical wedge

  12. Assessment of behavioral changes associated with oral meloxicam administration at time of dehorning in calves using a remote triangulation device and accelerometers

    Directory of Open Access Journals (Sweden)

    Theurer Miles E

    2012-04-01

    Full Text Available Abstract Background Dehorning is common in the cattle industry, and there is a need for research evaluating pain mitigation techniques. The objective of this study was to determine the effects of oral meloxicam, a non-steroidal anti-inflammatory, on cattle behavior post-dehorning by monitoring the percent of time spent standing, walking, and lying in specific locations within the pen using accelerometers and a remote triangulation device. Twelve calves approximately ten weeks of age were randomized into 2 treatment groups (meloxicam or control in a complete block design by body weight. Six calves were orally administered 0.5 mg/kg meloxicam at the time of dehorning and six calves served as negative controls. All calves were dehorned using thermocautery and behavior of each calf was continuously monitored for 7 days after dehorning using accelerometers and a remote triangulation device. Accelerometers monitored lying behavior and the remote triangulation device was used to monitor each calf’s movement within the pen. Results Analysis of behavioral data revealed significant interactions between treatment (meloxicam vs. control and the number of days post dehorning. Calves that received meloxicam spent more time at the grain bunk on trial days 2 and 6 post-dehorning; spent more time lying down on days 1, 2, 3, and 4; and less time at the hay feeder on days 0 and 1 compared to the control group. Meloxicam calves tended to walk more at the beginning and end of the trial compared to the control group. By day 5, the meloxicam and control group exhibited similar behaviors. Conclusions The noted behavioral changes provide evidence of differences associated with meloxicam administration. More studies need to be performed to evaluate the relationship of behavior monitoring and post-operative pain. To our knowledge this is the first published report demonstrating behavioral changes following dehorning using a remote triangulation device in conjunction

  13. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    Science.gov (United States)

    Roberts, B.

    1986-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  14. Small angle neutron scattering

    Directory of Open Access Journals (Sweden)

    Cousin Fabrice

    2015-01-01

    Full Text Available Small Angle Neutron Scattering (SANS is a technique that enables to probe the 3-D structure of materials on a typical size range lying from ∼ 1 nm up to ∼ a few 100 nm, the obtained information being statistically averaged on a sample whose volume is ∼ 1 cm3. This very rich technique enables to make a full structural characterization of a given object of nanometric dimensions (radius of gyration, shape, volume or mass, fractal dimension, specific area… through the determination of the form factor as well as the determination of the way objects are organized within in a continuous media, and therefore to describe interactions between them, through the determination of the structure factor. The specific properties of neutrons (possibility of tuning the scattering intensity by using the isotopic substitution, sensitivity to magnetism, negligible absorption, low energy of the incident neutrons make it particularly interesting in the fields of soft matter, biophysics, magnetic materials and metallurgy. In particular, the contrast variation methods allow to extract some informations that cannot be obtained by any other experimental techniques. This course is divided in two parts. The first one is devoted to the description of the principle of SANS: basics (formalism, coherent scattering/incoherent scattering, notion of elementary scatterer, form factor analysis (I(q→0, Guinier regime, intermediate regime, Porod regime, polydisperse system, structure factor analysis (2nd Virial coefficient, integral equations, characterization of aggregates, and contrast variation methods (how to create contrast in an homogeneous system, matching in ternary systems, extrapolation to zero concentration, Zero Averaged Contrast. It is illustrated by some representative examples. The second one describes the experimental aspects of SANS to guide user in its future experiments: description of SANS spectrometer, resolution of the spectrometer, optimization of

  15. In vitro tests for aerosol deposition. III: effect of inhaler insertion angle on aerosol deposition.

    Science.gov (United States)

    Delvadia, Renish R; Longest, P Worth; Hindle, Michael; Byron, Peter R

    2013-06-01

    Inhaler orientation with respect to a patient's mouth may be an important variable determining the efficiency of aerosol lung delivery. The effect of insertion angle on regional deposition was evaluated for a series of inhalers using concurrent in vitro and computational fluid dynamics (CFD) analysis. Geometrically realistic physical mouth-throat (MT) and upper tracheobronchial (TB) models were constructed to connect different inhalers at a series of insertion angles relative to the horizontal plane of the model. These models were used to assess albuterol sulfate deposition from the Novolizer(®) dry powder inhaler (DPI), Proventil(®) HFA pressurized metered dose inhaler (MDI), and Respimat(®) Soft Mist™ Inhaler (SMI) following the actuation of a single dose. Drug deposition from Novolizer DPI was studied for Salbulin(®) and an experimental "drug only" formulation. Albuterol sulfate was recovered and quantified from the device and the MT and TB regions. Significant differences in MT and total lung dose (TLD) of albuterol sulfate deposition were not observed for Salbulin Novolizer DPI and Respimat SMI inserted at different angles. In contrast, drug-only Novolizer DPI and Proventil HFA MDI showed a significant difference in MT and TLD deposition using different insertion angles. For drug-only Novolizer DPI and Proventil HFA MDI, the lowest and the highest MT depositions were observed at +10° and -20°, respectively; for Respimat SMI and Salbulin Novolizer DPI, these angles were -10° and +10°, and +20° and -20°, respectively. CFD simulations were in agreement with the experimental results and illustrated shifts in local particle deposition associated with changes in insertion angle. The effect of inhaler orientation at the inhaler-mouth interface on MT aerosol deposition appeared to be dependent on velocity, aerosol size, and formulation. These findings not only demonstrate the need for patient education on correct inhaler orientation, but provide important

  16. The Effect of Gap Angle on Tensile Strength of Preceramic Base Metal Solder Joints.

    Science.gov (United States)

    Fattahi, Farnaz; Hashemi Ardakani, Zahra; Hashemi Ardakani, Maryam

    2015-12-01

    Soldering is a process commonly used in fabricating dental prosthesis. Since most soldered prosthesis fail at the solder joints; the joint strength is of utmost importance. The purpose of this study was to evaluate the effect of gap angle on the tensile strength of base metal solder joints. A total number of 40 Ni-Cr samples were fabricated according to ADA/ISO 9693 specifications for tensile test. Samples were cut at the midpoint of the bar, and were placed at the considered angles by employing an explicitly designed device. They were divided into 4 groups regarding the gap angle; Group C (control group) with parallel gap on steady distance of 0.2mm, Group 1: 10°, Group 2: 20°, and Group3: 30° gap angles. When soldered, the specimens were all tested for tensile strength using a universal testing machine at a cross-head speed of 0.5 mm/min with a preload of 10N. Kruskal-Wallis H test was used to compare tensile strength among the groups (ptensile strength values obtained from the study groups were respectively 307.84, 391.50, 365.18, and 368.86 MPa. The tensile strength was not statistically different among the four groups in general (p≤ 0.490). Making the gap angular at the solder joints and the subsequent unsteady increase of the gap distance would not change the tensile strength of the joint.

  17. Inspection device in liquid

    International Nuclear Information System (INIS)

    Nagaoka, Etsuo.

    1996-01-01

    The present invention provides an inspection device in PWR reactor core in which inspection operations are made efficient by stabilizing a posture of the device in front-to-back, vertical and left-to-right directions by a simple structure. When the device conducts inspection while running in liquid, the front and the back directions of the device main body are inspected using a visual device while changing the posture by operating a front-to-back direction propulsion device and a right-to-left direction propulsion device, and a vertical direction propulsion device against to rolling, pitching and yawing of the device main body. In this case, a spherical magnet moves freely in the gravitational direction in a vibration-damping fluid in a non-magnetic spherical shell following the change of the posture of the device main body, in which the vibrations due to the movement of the spherical magnet is settled by the vibration-damping fluid thereby stabilizing the posture of the device main body. At a typical inspection posture, the settling effect is enhanced by the attraction force between the spherical magnets in the spherical shell and each of magnetic force-attracted magnetic members disposed to the outer circumference of the shell, and the posture of the device main body can be confirmed in front-to-back, right-to-left and vertical directions by each of the posture confirming magnetic sensors. (N.H.)

  18. Freestanding nanostructures via reactive ion beam angled etching

    Directory of Open Access Journals (Sweden)

    Haig A. Atikian

    2017-05-01

    Full Text Available Freestanding nanostructures play an important role in optical and mechanical devices for classical and quantum applications. Here, we use reactive ion beam angled etching to fabricate optical resonators in bulk polycrystalline and single crystal diamond. Reported quality factors are approximately 30 000 and 286 000, respectively. The devices show uniformity across 25 mm samples, a significant improvement over comparable techniques yielding freestanding nanostructures.

  19. Faraday cage angled-etching of nanostructures in bulk dielectrics

    OpenAIRE

    Latawiec, Pawel; Burek, Michael J.; Sohn, Young-Ik; Lončar, Marko

    2016-01-01

    For many emerging optoelectronic materials, heteroepitaxial growth techniques do not offer the same high material quality afforded by bulk, single-crystal growth. However, the need for optical, electrical, or mechanical isolation at the nanoscale level often necessitates the use of a dissimilar substrate, upon which the active device layer stands. Faraday cage angled-etching (FCAE) obviates the need for these planar, thin-film technologies by enabling in-situ device release and isolation thro...

  20. Automated analysis of angle closure from anterior chamber angle images.

    Science.gov (United States)

    Baskaran, Mani; Cheng, Jun; Perera, Shamira A; Tun, Tin A; Liu, Jiang; Aung, Tin

    2014-10-21

    To evaluate a novel software capable of automatically grading angle closure on EyeCam angle images in comparison with manual grading of images, with gonioscopy as the reference standard. In this hospital-based, prospective study, subjects underwent gonioscopy by a single observer, and EyeCam imaging by a different operator. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. An eye was classified as having angle closure if there were two or more quadrants of closure. Automated grading of the angle images was performed using customized software. Agreement between the methods was ascertained by κ statistic and comparison of area under receiver operating characteristic curves (AUC). One hundred forty subjects (140 eyes) were included, most of whom were Chinese (102/140, 72.9%) and women (72/140, 51.5%). Angle closure was detected in 61 eyes (43.6%) with gonioscopy in comparison with 59 eyes (42.1%, P = 0.73) using manual grading, and 67 eyes (47.9%, P = 0.24) with automated grading of EyeCam images. The agreement for angle closure diagnosis between gonioscopy and both manual (κ = 0.88; 95% confidence interval [CI), 0.81-0.96) and automated grading of EyeCam images was good (κ = 0.74; 95% CI, 0.63-0.85). The AUC for detecting eyes with gonioscopic angle closure was comparable for manual and automated grading (AUC 0.974 vs. 0.954, P = 0.31) of EyeCam images. Customized software for automated grading of EyeCam angle images was found to have good agreement with gonioscopy. Human observation of the EyeCam images may still be needed to avoid gross misclassification, especially in eyes with extensive angle closure. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  1. The Pocketable Electronic Devices in Radiation Oncology (PEDRO) Project: How the Use of Tools in Medical Decision Making is Changing?

    Science.gov (United States)

    De Bari, Berardino; Franco, Pierfrancesco; Niyazi, Maximilian; Cornetto, Andrea Peruzzo; Qvortrup, Camilla; Martin, Arturo Navarro; Cacicedo, Jon; Fernandez, Gonçalo; Louro, Luís Vasco; Lestrade, Laëtitia; Ciammella, Patrizia; Greto, Daniela; Checkrine, Tarik; Youssef, Elkholti; Filippi, Andrea Riccardo; Poulsen, Laurids Østergaard; Alongi, Filippo

    2016-04-01

    To analyze the impact of mobile electronic devices (MEDs) and apps in the daily clinical activity of young radiation or clinical oncologists in 5 Western European countries (Italy, Germany, Spain, Portugal, and Denmark). A web-based questionnaire was sent to 462 young (≤40 years) members of the national radiation or clinical oncology associations of the countries involved in the study. The 15 items investigated diffusion of MEDs (smartphones and/or tablets), their impact on daily clinical activity, and the differences perceived by participants along time. A total of 386 (83.5%) of the 462 correctly filled questionnaires were statistically evaluated. Up to 65% of respondents declared to use an electronic device during their clinical activity. Conversely, 72% considered low to moderate impact of smartphones/tables on their daily practice. The daily use significantly increased from 2009 to 2012: users reporting a use ≥6 times/d raised from 5% to 39.9%. Professional needs fulfillment was declared by less than 68% of respondents and compliance to apps indications by 66%. Significant differences were seen among the countries, in particular concerning the feeling of usefulness of MEDs in the daily clinical life. The perception of the need of a comprehensive Web site containing a variety of applications (apps) for clinical use significantly differed among countries in 2009, while it was comparable in 2012. This survey showed a large diffusion of MEDs in young professionals working in radiation oncology. Looking at these data, it is important to verify the consistency of information found within apps, in order to avoid potential errors eventually detrimental for patients. "Quality assurance" criteria should be specifically developed for medical apps and a comprehensive Web site gathering all reliable applications and tools might be useful for daily clinical practice. © The Author(s) 2015.

  2. From every angle

    CERN Multimedia

    Anaïs Schaeffer

    2013-01-01

    For nearly 60 years, CERN’s surveyors have measured the Laboratory’s tunnels and caverns both in preparation for the accurate positioning of magnets and detectors, and to plot their shapes, dimensions and other lumps and bumps. Now that they have the very latest 3D laser scanner, nothing will get past them.   A measurement campaign carried out using laser scanners in the ISOLDE Hall. About 15 years ago, the arrival of 3D laser scanners, digital devices which can reconstruct various objects in the form of 3D images, opened the door to a whole host of possibilities in the topography world. These new tools have been used at CERN since 2004 to produce increasingly detailed digital images of the LHC tunnels and experiments. The CERN surveyors’ high-performance laser scanner has become an irreplaceable tool in many instances. It is capable of measuring every 2 millimetres from a distance of 10 metres (and therefore 4 millimetres from a distance of 2...

  3. Animal magnetocardiography using superconducting quantum interference device gradiometers assisted with magnetic nanoparticle injection: A sensitive method for early detecting electromagnetic changes induced by hypercholesterolemia

    Science.gov (United States)

    Wu, C. C.; Hong, B. F.; Wu, B. H.; Yang, S. Y.; Horng, H. E.; Yang, H. C.; Tseng, W. Y. Isaac; Tseng, W. K.; Liu, Y. B.; Lin, L. C.; Lu, L. S.; Lee, Y. H.

    2007-01-01

    In this work, the authors used a superconducting quantum interference device (SQUID) magnetocardiography (MCG) system consisted of 64-channel low-transition-temperature SQUID gradiometers to detect the MCG signals of hepercholesterolemic rabbits. In addition, the MCG signals were recorded before and after the injection of magnetic nanoparticles into the rabbits' ear veins to investigate the effects of magnetic nanoparticles on the MCG signals. These MCG data were compared to those of normal rabbits to reveal the feasibility for early detection of the electromagnetic changes induced by hypercholesterolemia using MCG with the assistance of magnetic nanoparticle injection.

  4. Measurement of the angle gamma

    International Nuclear Information System (INIS)

    Aleksan, R.; Sphicas, P.; Massachusetts Inst. of Tech., Cambridge, MA

    1993-12-01

    The angle γ as defined in the Wolfenstein approximation is not completely out of reach of current or proposed dedicated B experiments. This work represents but a first step in the direction of extracting the third angle of the unitarity triangle by study the feasibility of using new decay modes in a hadronic machine. (A.B.). 11 refs., 1 fig., 7 tabs

  5. Nucleation of small angle boundaries

    CSIR Research Space (South Africa)

    Nabarro, FRN

    1996-12-01

    Full Text Available The internal stresses induced by the strain gradients in an array of lattice cells delineated by low-angle dislocation boundaries are partially relieved by the creation of new low-angle boundaries. This is shown to be a first-order transition...

  6. Device for regulating light water nuclear reactors by changing the boric acid concentration in the cooling water circuit

    International Nuclear Information System (INIS)

    Brown, W.W.; Van der Schoot, M.R.

    1980-01-01

    Small changes in boric acid concentration can be carried out quickly by a combination of an ion exchanger with temperature-dependent capacity and an evaporator. No boric acid need be extracted from the circuit or added to it. However, if large changes of concentration are required, boric acid has to be added. The evaporator is then used to separate distilled water and concentrated boric acid when the cooling water is diluted. (DG) [de

  7. Self-tracking solar concentrator with an acceptance angle of 32°.

    Science.gov (United States)

    Zagolla, Volker; Dominé, Didier; Tremblay, Eric; Moser, Christophe

    2014-12-15

    Solar concentration has the potential to decrease the cost associated with solar cells by replacing the receiving surface aperture with cheaper optics that concentrate light onto a smaller cell aperture. However a mechanical tracker has to be added to the system to keep the concentrated light on the size reduced solar cell at all times. The tracking device itself uses energy to follow the sun's position during the day. We have previously shown a mechanism for self-tracking that works by making use of the infrared energy of the solar spectrum, to activate a phase change material. In this paper, we show an implementation of a working 53 x 53 mm(2) self-tracking system with an acceptance angle of 32° ( ± 16°). This paper describes the design optimizations and upscaling process to extend the proof-of-principle self-tracking mechanism to a working demonstration device including the incorporation of custom photodiodes for system characterization. The current version demonstrates an effective concentration of 3.5x (compared to 8x theoretical) over 80% of the desired acceptance angle. Further improvements are expected to increase the efficiency of the system and open the possibility to expand the device to concentrations as high as 200x (C(geo) = 400x, η = 50%, for a solar cell matched spectrum).

  8. Variable-flip-angle spin-echo imaging (VFSE)

    International Nuclear Information System (INIS)

    Kasai, Toshifumi; Sugimura, Kazuro; Kawamitsu, Hideaki; Yasui, Kiyoshi; Ishida, Tetsuya; Tsukamoto, Tetsuji.

    1990-01-01

    T 2 weighted imaging provides images with high object contrast for pathologic conditions in which the water content of tissues is increased. The authors predicted theoretical analysis of the effects of changing flip angle, and analyzed the effects in MR imaging of both phantoms and humans. Variable flip angle spin echo MR imaging (VFSE) with a 1,000/80 (repetition time msec/echo time msec) can obtain T 2 weighted image when flip angle is smaller than 80 degrees. VFSE with 40 to 60 degrees flip angle have higher contrast than other flip angle images. Signal to noise ratio (S/N) of VFSE are 55% at a 30 degree, 76% at a 45 degree, 92% at a 60 degree respectively as compared with conventional spin echo image (2000/80, flip angle 90 degree). VFSE is applicable to obtain T 2 weighted image reduced imaging time. (author)

  9. Development of an angle-scanning spectropolarimeter: Preliminary results

    Science.gov (United States)

    Nouri, Sahar A.; Gregory, Don A.; Fuller, Kirk

    2018-02-01

    A fixed-angle spectropolarimeter capable of measuring the Mueller matrix of particle deposits and conventional optical elements over the 300-1100 nm spectral range has been built, calibrated and extensively tested. A second generation of this instrument is being built which can scan from 0° to near 180° in both scattering angle and sample orientation, enabling studies of the bidirectional Mueller matrices of nanoparticle arrays, atmospheric aerosol deposits, and nano- and microstructured surfaces. This system will also provide a much needed metrology capability for fully characterizing the performance of optical devices and device components from the near-infrared through the medium wave ultraviolet. Experimental results taken using the first generation fixed-angle arrangement will be presented along with the rationale for building the second.

  10. The Effect of Inclination Angle on Critical Heat Flux in a Locally Heated Liquid Film Moving Under the Action of Gas Flow in a Mini-Channel

    Directory of Open Access Journals (Sweden)

    Tkachenko Egor M.

    2016-01-01

    Full Text Available Intensively evaporating liquid films moving under the action of the cocurrent gas flow in a microchannel are promising for the use in modern cooling systems of semiconductor devices with high local heat release. This work has studied the dependence of the critical heat flux on the inclination angle of the channel. It has been found that the inclination angle in the plane parallel to the flow has no significant effect on the critical heat flux. Whereas the inclination angle in the plane perpendicular to the flow, on the contrary, significantly changes the value of the critical heat flux. However, for a given flow rate of fluid there is a threshold gas velocity at which the critical heat flux does not differ from the case of zero inclination of the channel. Thus, it can be concluded that the cooling system based on shear-driven liquid films can be potentially used when direction of the gravity changes.

  11. Optimum tilt angle and orientation for solar collectors in Syria

    International Nuclear Information System (INIS)

    Skeiker, Kamal

    2009-01-01

    One of the important parameters that affect the performance of a solar collector is its tilt angle with the horizon. This is because of the variation of tilt angle changes the amount of solar radiation reaching the collector surface. A mathematical model was used for estimating the solar radiation on a tilted surface, and to determine the optimum tilt angle and orientation (surface azimuth angle) for the solar collector in the main Syrian zones, on a daily basis, as well as for a specific period. The optimum angle was computed by searching for the values for which the radiation on the collector surface is a maximum for a particular day or a specific period. The results reveal that changing the tilt angle 12 times in a year (i.e. using the monthly optimum tilt angle) maintains approximately the total amount of solar radiation near the maximum value that is found by changing the tilt angle daily to its optimum value. This achieves a yearly gain in solar radiation of approximately 30% more than the case of a solar collector fixed on a horizontal surface.

  12. Ultrathin metal-semiconductor-metal resonator for angle invariant visible band transmission filters

    International Nuclear Information System (INIS)

    Lee, Kyu-Tae; Seo, Sungyong; Yong Lee, Jae; Jay Guo, L.

    2014-01-01

    We present transmission visible wavelength filters based on strong interference behaviors in an ultrathin semiconductor material between two metal layers. The proposed devices were fabricated on 2 cm × 2 cm glass substrate, and the transmission characteristics show good agreement with the design. Due to a significantly reduced light propagation phase change associated with the ultrathin semiconductor layer and the compensation in phase shift of light reflecting from the metal surface, the filters show an angle insensitive performance up to ±70°, thus, addressing one of the key challenges facing the previously reported photonic and plasmonic color filters. This principle, described in this paper, can have potential for diverse applications ranging from color display devices to the image sensors.

  13. Relationship between the Angle of Repose and Angle of Internal ...

    African Journals Online (AJOL)

    ). The angle of internal friction ... compression chambers. Lorenzen, 1957 (quoted by Mohsenin,. 1986), reported that the design of deep ... tiongiven for lateral pressure in deep bins as presented by Mohsenin. (1986). The presence of moisture ...

  14. Three-dimensional transient cooling simulations of a portable electronic device using PCM (phase change materials) in multi-fin heat sink

    International Nuclear Information System (INIS)

    Wang, Yi-Hsien; Yang, Yue-Tzu

    2011-01-01

    Transient three-dimensional heat transfer numerical simulations were conducted to investigate a hybrid PCM (phase change materials) based multi-fin heat sink. Numerical computation was conducted with different amounts of fins (0 fin, 3 fins and 6 fins), various heating power level (2 W, 3 W and 4 W), different orientation tests (vertical/horizontal/slanted), and charge and discharge modes. Calculating time step (0.03 s, 0.05 s, and 0.07 s) size was discussed for transient accuracy as well. The theoretical model developed is validated by comparing numerical predictions with the available experimental data in the literature. The results showed that the transient surface temperatures are predicted with a maximum discrepancy within 10.2%. The operation temperature can be controlled well by the attendance of phase change material and the longer melting time can be conducted by using a multi-fin hybrid heat sink respectively. -- Highlights: → Electronic device cooling use phase change materials. → N-eicosane is adapted as phase change materials. → Present surface transient temperatures prediction error is within 10.2%. → Hybrid PCM-heat sink system provides stable operation temperature. → Orientation effects show independent on the phase change performance.

  15. Power generating device

    Energy Technology Data Exchange (ETDEWEB)

    Onodera, Toshihiro

    1989-05-02

    The existing power generating device consisting of static components only lacks effective measures to utilize solar energy and maintain power generation, hence it is inevitable to make the device much larger and more complicated in order to utilize it as the primary power source for artificial satellites. In view of the above, in order to offer a power generating device useful for the primary power source for satellites which is simple and can keep power generation by solar energy, this invention proposes a power generating device composed of the following elements: (1) a rectangular parallelopiped No. II superconductor plate; (2) a measure to apply a magnetic field to one face of the above superconductor plate; (3) a measure to provide a temperature difference within the range between the starting temperature and the critical temperature of superconductivity to a pair of faces meeting at right angles with the face to which the magnetic field was applied by the above measure; (4) a measure to provide an electrode on each of the other pair of faces meeting at right angles with the face to which the magnetic field was applied by the above measure and form a closed circuit by connecting the each electrode above to each of a pair of electrodes of the load respectively; and (5) a switching measure which is installed in the closed circuit prepared by the above measure and shuts off the closed circuit when the direction of the electric current running the above closed circuit is reversed. 6 figs.

  16. Design of a self-calibration high precision micro-angle deformation optical monitoring scheme

    Science.gov (United States)

    Gu, Yingying; Wang, Li; Guo, Shaogang; Wu, Yun; Liu, Da

    2018-03-01

    In order to meet the requirement of high precision and micro-angle measurement on orbit, a self-calibrated optical non-contact real-time monitoring device is designed. Within three meters, the micro-angle variable of target relative to measuring basis can be measured in real-time. The range of angle measurement is +/-50'', the angle measurement accuracy is less than 2''. The equipment can realize high precision real-time monitoring the micro-angle deformation, which caused by high strength vibration and shock of rock launching, sun radiation and heat conduction on orbit and so on.

  17. Viewing angle switching of patterned vertical alignment liquid crystal display

    International Nuclear Information System (INIS)

    Lim, Young Jin; Jeong, Eun; Chin, Mi Hyung; Lee, Seung Hee; Ji, Seunghoon; Lee, Gi-Dong

    2008-01-01

    Viewing angle control of a patterned vertical alignment (PVA) liquid crystal display using only one panel is investigated. In conventional PVA modes, a vertically aligned liquid crystal (LC) director tilts down in four directions making 45 deg. with respect to crossed polarizers to exhibit a wide viewing angle. In the viewing angle control device, one pixel was divided into two sub-pixels such that the LC director in the main pixel is controlled to be tilted down in multiple directions making an angle with the polarizer, playing the role of main display with the wide viewing angle, while the LC director in the sub-pixel is controlled to be tilted down to the polarizer axis, playing the role of sub-pixel to the viewing angle control for the narrow viewing angle. Using sub-pixel control, light leakage or any type of information such as characters and image can be generated in oblique viewing directions without distorting the image quality in the normal direction, which will prevent others from peeping at the displayed image by overlapping the displayed image with the made image

  18. Two Comments on Bond Angles

    Science.gov (United States)

    Glaister, P.

    1997-09-01

    Tetrahedral Bond Angle from Elementary Trigonometry The alternative approach of using the scalar (or dot) product of vectors enables the determination of the bond angle in a tetrahedral molecule in a simple way. There is, of course, an even more straightforward derivation suitable for students who are unfamiliar with vectors, or products thereof, but who do know some elementary trigonometry. The starting point is the figure showing triangle OAB. The point O is the center of a cube, and A and B are at opposite corners of a face of that cube in which fits a regular tetrahedron. The required bond angle alpha = AÔB; and using Pythagoras' theorem, AB = 2(square root 2) is the diagonal of a face of the cube. Hence from right-angled triangle OEB, tan(alpha/2) = (square root 2) and therefore alpha = 2tan-1(square root 2) is approx. 109° 28' (see Fig. 1).

  19. ASSESSMENT OF LENS THICKNESS IN ANGLE CLOSURE DISEASE

    Directory of Open Access Journals (Sweden)

    Nishat Sultana Khayoom

    2016-08-01

    Full Text Available BACKGROUND Anterior chamber depth and lens thickness have been considered as important biometric determinants in primary angle-closure glaucoma. Patients with primary narrow angle may be classified as a primary angle closure suspect (PACS, or as having primary angle closure (PAC or primary angle closure glaucoma (PACG. 23.9% of patients with primary angle closure disease are in India, which highlights the importance of understanding the disease, its natural history, and its underlying pathophysiology, so that we may try to establish effective methods of treatment and preventative measures to delay, or even arrest, disease progression, thereby reducing visual morbidity. AIM To determine the lens thickness using A-scan biometry and its significance in various stages of angle closure disease. MATERIALS AND METHODS Patients attending outpatient department at Minto Ophthalmic Hospital between October 2013 to May 2015 were screened for angle closure disease and subsequently evaluated at glaucoma department. In our study, lens thickness showed a direct correlation with shallowing of the anterior chamber by determining the LT/ ACD ratio. A decrease in anterior chamber depth is proportional to the narrowing of the angle which contributes to the progression of the angle closure disease from just apposition to occlusion enhancing the risk for optic nerve damage and visual field loss. Hence, if the lens thickness values are assessed earlier in the disease process, appropriate intervention can be planned. CONCLUSION Determination of lens changes along with anterior chamber depth and axial length morphometrically can aid in early detection of angle closure. The role of lens extraction for PACG is a subject of increased interest. Lens extraction promotes the benefits of anatomical opening of the angle, IOP reduction and improved vision. This potential intervention may be one among the armamentarium of approaches for PACG. Among the current treatment modalities

  20. The phase-change kinetics of amorphous Ge2Sb2Te5 and device characteristics investigated by thin-film mechanics

    International Nuclear Information System (INIS)

    Cho, Ju-Young; Kim, Dohyung; Park, Yong-Jin; Yang, Tae-Youl; Lee, Yoo-Yong; Joo, Young-Chang

    2015-01-01

    For high switching speed and high reliability of phase-change random access memory (PcRAM), we need to identify materials that enable fast crystallization at elevated temperatures but are stable at and above room temperature. Achieving this goal requires a breakthrough in our understanding of the unique crystallization kinetics of amorphous phase change materials as a fragile glass, described as the non-Arrhenius behavior of atomic mobility. It is a highly rewarding task to unravel the unconventional crystallization kinetics and related properties, because these properties can be utilized to predict the device characteristics. This manuscript utilizes the thin-film mechanics to investigate the crystallization kinetics of amorphous Ge 2 Sb 2 Te 5 phase-change materials doped with Al, Bi, C and N, which is an effective method to analyze the structural changes in amorphous materials. Crystallization temperature, super-cooled liquid region, glass transition temperature and fragility are measured to describe the crystallization kinetics tuned by doping; characteristic fragile-to-strong transition is observed for C and N dopings due to their structural feature as an interstitial dopant. Consequently, doping effects on the phase stability and atomic mobility manifested by the crystallization temperature and the super-cooled liquid region (or 1/fragility) successfully correspond with PcRAM characteristics, i.e., reliability and switching speed, respectively

  1. Comparative Effectiveness of Different Phase Change Materials to Improve Cooling Performance of Heat Sinks for Electronic Devices

    Directory of Open Access Journals (Sweden)

    Ahmad Hasan

    2016-08-01

    Full Text Available This paper thermo-physically characterizes salt hydrate, paraffin wax and milk fat as phase change materials (PCMs. The three PCMs are compared in terms of improving heat sink (HS performance for cooling electronic packaging. An experimental study is carried out on commercially available finned HS with and without PCM under natural ventilation (NV and forced ventilation (FV at different heat loads (4 W to 10 W. The results indicate that integration of all of the PCMs into the HS improves its cooling performance; however, milk fat lags behind the other two PCMs in terms of cooling produced. A three-dimensional pressure-based conjugate heat transfer model has been developed and validated with experimental results. The model predicts the parametric influence of PCM melting range, thermal conductivity and density on HS thermal management performance. The HS cooling performance improves with increased density and conductivity while it deteriorates with the wider melting range of the PCMs.

  2. Demonstration of angle widening using EyeCam after laser peripheral iridotomy in eyes with angle closure.

    Science.gov (United States)

    Perera, Shamira A; Quek, Desmond T; Baskaran, Mani; Tun, Tin A; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2010-06-01

    To evaluate EyeCam in detecting changes in angle configuration after laser peripheral iridotomy (LPI) in comparison to gonioscopy, the reference standard. Prospective comparative study. Twenty-four subjects (24 eyes) with primary angle-closure glaucoma (PACG) were recruited. Gonioscopy and EyeCam (Clarity Medical Systems) imaging of all 4 angle quadrants were performed, before and 2 weeks after LPI. Images were graded according to angle structures visible by an observer masked to clinical data or the status of LPI, and were performed in a random order. Angle closure in a quadrant was defined as the inability to visualize the posterior trabecular meshwork. We determined the number of quadrants with closed angles and the mean number of clock hours of angle closure before and after LPI in comparison to gonioscopy. Using EyeCam, all 24 eyes showed at least 1 quadrant of angle widening after LPI. The mean number of clock hours of angle closure decreased significantly, from 8.15 +/- 3.47 clock hours before LPI to 1.75 +/- 2.27 clock hours after LPI (P gonioscopy showed 1.0 +/- 1.41 (95% CI, 0.43-1.57) quadrants opening from closed to open after LPI compared to 2.0 +/- 1.28 (95% CI, 1.49-2.51, P = .009) quadrants with EyeCam. Intra-observer reproducibility of grading the extent of angle closure in clock hours in EyeCam images was moderate to good (intraclass correlation coefficient 0.831). EyeCam may be used to document changes in angle configuration after LPI in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.

  3. Dancing droplets: Contact angle, drag, and confinement

    Science.gov (United States)

    Benusiglio, Adrien; Cira, Nate; Prakash, Manu

    2015-11-01

    When deposited on a clean glass slide, a mixture of water and propylene glycol forms a droplet of given contact angle, when both pure liquids spread. (Cira, Benusiglio, Prakash: Nature, 2015). The droplet is stabilized by a gradient of surface tension due to evaporation that induces a Marangoni flow from the border to the apex of the droplets. The apparent contact angle of the droplets depends on both their composition and the external humidity as captured by simple models. These droplets present remarkable properties such as lack of a large pinning force. We discuss the drag on these droplets as a function of various parameters. We show theoretical and experimental results of how various confinement geometries change the vapor gradient and the dynamics of droplet attraction.

  4. Didactical Design Enrichment of Angle in Geometry

    Science.gov (United States)

    Setiadi, D. R.; Suryadi, D.; Mulyana, E.

    2017-09-01

    The underlying problem of this research is the lack of student’s competencies in understanding the concept of angle in geometry as the results of the teaching and learning pattern that only to receive the topic rather than to construct the topic and has not paid attention to the learning trajectory. The purpose of this research is to develop the didactical design of angle in space learning activity. The used research method is a method of qualitative research in the form of a didactical design research through three phases of analysis i.e. didactical situation analysis, metapedadidactical analysis, and retrospective analysis, which conducted in students from 10th grade at one of private schools in Bandung. Based on the results of research and discussion, the didactical design that has been made, is capable to change student’s learning habit and quite capable to develop student’s competencies although not optimal.

  5. Are ultrasound-guided ophthalmic blocks injurious to the eye? A comparative rabbit model study of two ultrasound devices evaluating intraorbital thermal and structural changes.

    Science.gov (United States)

    Palte, Howard D; Gayer, Steven; Arrieta, Esdras; Scot Shaw, Eric; Nose, Izuru; Lee, Elizabete; Arheart, Kristopher L; Dubovy, Sander; Birnbach, David J; Parel, Jean-Marie

    2012-07-01

    Since Atkinson's original description of retrobulbar block in 1936, needle-based anesthetic techniques have become integral to ophthalmic anesthesia. These techniques are unfortunately associated with rare, grave complications such as globe perforation. Ultrasound has gained widespread acceptance for peripheral nerve blockade, but its translation to ocular anesthesia has been hampered because sonic energy, in the guise of thermal or biomechanical insult, is potentially injurious to vulnerable eye tissue. The US Food and Drug Administration (FDA) has defined guidelines for safe use of ultrasound for ophthalmic examination, but most ultrasound devices used by anesthesiologists are not FDA-approved for ocular application because they generate excessive energy. Regulating agencies state that ultrasound examinations can be safely undertaken as long as tissue temperatures do not increase >1.5°C above physiological levels. Using a rabbit model, we investigated the thermal and mechanical ocular effects after prolonged ultrasonic exposure to single orbital- and nonorbital-rated devices. In a dual-phase study, aimed at detecting ocular injury, the eyes of 8 rabbits were exposed to continuous 10-minute ultrasound examinations from 2 devices: (1) the Sonosite Micromaxx (nonorbital rated) and (2) the Sonomed VuMax (orbital rated) machines. In phase I, temperatures were continuously monitored via thermocouples implanted within specific eye structures (n = 4). In phase II the eyes were subjected to ultrasonic exposure without surgical intervention (n = 4). All eyes underwent light microscopy examinations, followed at different intervals by histology evaluations conducted by an ophthalmic pathologist. Temperature changes were monitored in the eyes of 4 rabbits. The nonorbital-rated transducer produced increases in ocular tissue temperature that surpassed the safe limit (increases >1.5°C) in the lens of 3 rabbits (at 5.0, 5.5, and 1.5 minutes) and cornea of 2 rabbits (both at 1

  6. Photovoltaic device

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Jason A; Keenihan, James R; Gaston, Ryan S; Kauffmann, Keith L; Langmaid, Joseph A; Lopez, Leonardo; Maak, Kevin D; Mills, Michael E; Ramesh, Narayan; Teli, Samar R

    2017-03-21

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  7. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-06-02

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  8. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  9. Contact angle control of sessile drops on a tensioned web

    Science.gov (United States)

    Park, Janghoon; Kim, Dongguk; Lee, Changwoo

    2018-04-01

    In this study, the influence of the change of tension applied to flexible and thin web substrate on the contact angle of sessile drop in roll-to-roll system was investigated. Graphene oxide and deionized water solutions were used in the experiments. Tension was changed to 29, 49, and 69 N, and the casting distance of the micropipette and the material was set to 10, 20, and 40 mm, and the droplet volume was set to 10, 20, and 30 μL, respectively. Statistical analysis of three variables and analysis of the variance methodology showed that the casting distance was most significant for the contact angle change, and the most interesting tension variable was also affected. The change in tension caused the maximum contact angle to change by 5.5°. The tension was not uniform in the width direction. When the droplet was applied in the same direction in the width direction, it was confirmed that the tension unevenness had great influence on the contact angle up to 11°. Finally, the casting distance, which has a large effect on the contact angle, was calibrated in the width direction to reduce the width direction contact angle deviation to 1%. This study can be applied to fine patterning research using continuous inkjet printing and aerosol jet printing, which are roll-to-roll processes based on droplet handling.

  10. Metasurface Enabled Wide-Angle Fourier Lens.

    Science.gov (United States)

    Liu, Wenwei; Li, Zhancheng; Cheng, Hua; Tang, Chengchun; Li, Junjie; Zhang, Shuang; Chen, Shuqi; Tian, Jianguo

    2018-06-01

    Fourier optics, the principle of using Fourier transformation to understand the functionalities of optical elements, lies at the heart of modern optics, and it has been widely applied to optical information processing, imaging, holography, etc. While a simple thin lens is capable of resolving Fourier components of an arbitrary optical wavefront, its operation is limited to near normal light incidence, i.e., the paraxial approximation, which puts a severe constraint on the resolvable Fourier domain. As a result, high-order Fourier components are lost, resulting in extinction of high-resolution information of an image. Other high numerical aperture Fourier lenses usually suffer from the bulky size and costly designs. Here, a dielectric metasurface consisting of high-aspect-ratio silicon waveguide array is demonstrated experimentally, which is capable of performing 1D Fourier transform for a large incident angle range and a broad operating bandwidth. Thus, the device significantly expands the operational Fourier space, benefitting from the large numerical aperture and negligible angular dispersion at large incident angles. The Fourier metasurface will not only facilitate efficient manipulation of spatial spectrum of free-space optical wavefront, but also be readily integrated into micro-optical platforms due to its compact size. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Nanoscale surface modifications to control capillary flow characteristics in PMMA microfluidic devices

    Directory of Open Access Journals (Sweden)

    Mukhopadhyay Subhadeep

    2011-01-01

    Full Text Available Abstract Polymethylmethacrylate (PMMA microfluidic devices have been fabricated using a hot embossing technique to incorporate micro-pillar features on the bottom wall of the device which when combined with either a plasma treatment or the coating of a diamond-like carbon (DLC film presents a range of surface modification profiles. Experimental results presented in detail the surface modifications in the form of distinct changes in the static water contact angle across a range from 44.3 to 81.2 when compared to pristine PMMA surfaces. Additionally, capillary flow of water (dyed to aid visualization through the microfluidic devices was recorded and analyzed to provide comparison data between filling time of a microfluidic chamber and surface modification characteristics, including the effects of surface energy and surface roughness on the microfluidic flow. We have experimentally demonstrated that fluid flow and thus filling time for the microfluidic device was significantly faster for the device with surface modifications that resulted in a lower static contact angle, and also that the incorporation of micro-pillars into a fluidic device increases the filling time when compared to comparative devices.

  12. Frequency scaling for angle gathers

    KAUST Repository

    Zuberi, M. A H; Alkhalifah, Tariq Ali

    2014-01-01

    Angle gathers provide an extra dimension to analyze the velocity after migration. Space-shift and time shift-imaging conditions are two methods used to obtain angle gathers, but both are reasonably expensive. By scaling the time-lag axis of the time-shifted images, the computational cost of the time shift imaging condition can be considerably reduced. In imaging and more so Full waveform inversion, frequencydomain Helmholtz solvers are used more often to solve for the wavefields than conventional time domain extrapolators. In such cases, we do not need to extend the image, instead we scale the frequency axis of the frequency domain image to obtain the angle gathers more efficiently. Application on synthetic data demonstrate such features.

  13. Effects of knee extension constraint training on knee flexion angle and peak impact ground-reaction force.

    Science.gov (United States)

    Liu, Hui; Wu, Will; Yao, Wanxiang; Spang, Jeffrey T; Creighton, R Alexander; Garrett, William E; Yu, Bing

    2014-04-01

    Low compliance with training programs is likely to be one of the major reasons for inconsistency of the data regarding the effectiveness of current anterior cruciate ligament (ACL) injury prevention programs. Training methods that reduce training time and cost could favorably influence the effectiveness of ACL injury prevention programs. A newly designed knee extension constraint training device may serve this purpose. (1) Knee extension constraint training for 4 weeks would significantly increase the knee flexion angle at the time of peak impact posterior ground-reaction force and decrease peak impact ground-reaction forces during landing of a stop-jump task and a side-cutting task, and (2) the training effects would be retained 4 weeks after completion of the training program. Controlled laboratory study. Twenty-four recreational athletes were randomly assigned to group A or B. Participants in group A played sports without wearing a knee extension constraint device for 4 weeks and then played sports while wearing the device for 4 weeks, while participants in group B underwent a reversed protocol. Both groups were tested at the beginning of week 1 and at the ends of weeks 4 and 8 without wearing the device. Knee joint angles were obtained from 3-dimensional videographic data, while ground-reaction forces were measured simultaneously using force plates. Analyses of variance were performed to determine the training effects and the retention of training effects. Participants in group A significantly increased knee flexion angles and decreased ground-reaction forces at the end of week 8 (P ≤ .012). Participants in group B significantly increased knee flexion angles and decreased ground-reaction forces at the ends of weeks 4 and 8 (P ≤ .007). However, participants in group B decreased knee flexion angles and increased ground-reaction forces at the end of week 8 in comparison with the end of week 4 (P ≤ .009). Knee extension constraint training for 4 weeks

  14. Simulation on a limited angle beam gamma ray tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jung, Sung Hee; Moon, Jin Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    Limited angle beam tomography was introduced in the medical field more than two decades ago, where it was mainly used for cardiovascular diagnostics. Later, it was also used to trace multiphase flows. In these studies, the detection systems were fixed and a scanning electron beam was rapidly swept across an xray target using deflection coils. Thus very fast scanning was possible in these studies, but their geometry resulted in a heavy and bulky system because of a complex control system and vacuum tube. Because of its heavy hardware, limited angle beam tomography has remained as indoor equipment. If the source section is replaced by a gamma ray source, limited angle beam tomography will have a very light source device. In addition, limited angle beam tomography with a gamma ray source can be designed using an open type portable gantry because it does not need a vacuum guide for an electron beam. There is a lot of need for a portable tomographic system but so far no definitive solution has been created. The inspection of industrial on-line pipes, wood telephone poles, and cultural assets are some application areas. This study introduces limited angle beam gamma ray tomography, its simulation, and image reconstruction results. Image reconstruction was performed on the virtual experimental data from a Monte Carlo simulation. Image reconstruction algorithms that are known to be useful for limited angle data were applied and their results compared

  15. A gallery approach for off-angle iris recognition

    Science.gov (United States)

    Karakaya, Mahmut; Yoldash, Rashiduddin; Boehnen, Christopher

    2015-05-01

    It has been proven that hamming distance score between frontal and off-angle iris images of same eye differs in iris recognition system. The distinction of hamming distance score is caused by many factors such as image acquisition angle, occlusion, pupil dilation, and limbus effect. In this paper, we first study the effect of the angle variations between iris plane and the image acquisition systems. We present how hamming distance changes for different off-angle iris images even if they are coming from the same iris. We observe that increment in acquisition angle of compared iris images causes the increment in hamming distance. Second, we propose a new technique in off-angle iris recognition system that includes creating a gallery of different off-angle iris images (such as, 0, 10, 20, 30, 40, and 50 degrees) and comparing each probe image with these gallery images. We will show the accuracy of the gallery approach for off-angle iris recognition.

  16. Variable angle asymmetric cut monochromator

    International Nuclear Information System (INIS)

    Smither, R.K.; Fernandez, P.B.

    1993-09-01

    A variable incident angle, asymmetric cut, double crystal monochromator was tested for use on beamlines at the Advanced Photon Source (APS). For both undulator and wiggler beams the monochromator can expand area of footprint of beam on surface of the crystals to 50 times the area of incident beam; this will reduce the slope errors by a factor of 2500. The asymmetric cut allows one to increase the acceptance angle for incident radiation and obtain a better match to the opening angle of the incident beam. This can increase intensity of the diffracted beam by a factor of 2 to 5 and can make the beam more monochromatic, as well. The monochromator consists of two matched, asymmetric cut (18 degrees), silicon crystals mounted so that they can be rotated about three independent axes. Rotation around the first axis controls the Bragg angle. The second rotation axis is perpendicular to the diffraction planes and controls the increase of the area of the footprint of the beam on the crystal surface. Rotation around the third axis controls the angle between the surface of the crystal and the wider, horizontal axis for the beam and can make the footprint a rectangle with a minimum. length for this area. The asymmetric cut is 18 degrees for the matched pair of crystals, which allows one to expand the footprint area by a factor of 50 for Bragg angles up to 19.15 degrees (6 keV for Si[111] planes). This monochromator, with proper cooling, will be useful for analyzing the high intensity x-ray beams produced by both undulators and wigglers at the APS

  17. Angle independent velocity spectrum determination

    DEFF Research Database (Denmark)

    2014-01-01

    An ultrasound imaging system (100) includes a transducer array (102) that emits an ultrasound beam and produces at least one transverse pulse-echo field that oscillates in a direction transverse to the emitted ultrasound beam and that receive echoes produced in response thereto and a spectral vel...... velocity estimator (110) that determines a velocity spectrum for flowing structure, which flows at an angle of 90 degrees and flows at angles less than 90 degrees with respect to the emitted ultrasound beam, based on the received echoes....

  18. Temperature dependence of Brewster's angle.

    Science.gov (United States)

    Guo, Wei

    2018-01-01

    In this work, a dielectric at a finite temperature is modeled as an ensemble of identical atoms moving randomly around where they are trapped. Light reflection from the dielectric is then discussed in terms of atomic radiation. Specific calculation demonstrates that because of the atoms' thermal motion, Brewster's angle is, in principle, temperature-dependent, and the dependence is weak in the low-temperature limit. What is also found is that the Brewster's angle is nothing but a result of destructive superposition of electromagnetic radiation from the atoms.

  19. Adaptive force regulation of muscle strengthening rehabilitation device with magnetorheological fluids.

    Science.gov (United States)

    Dong, Shufang; Lu, Ke-Qian; Sun, Jian Qiao; Rudolph, Katherine

    2006-03-01

    In rehabilitation from neuromuscular trauma or injury, strengthening exercises are often prescribed by physical therapists to recover as much function as possible. Strengthening equipment used in clinical settings range from low-cost devices, such as sandbag weights or elastic bands to large and expensive isotonic and isokinetic devices. The low-cost devices are incapable of measuring strength gains and apply resistance based on the lowest level of torque that is produced by a muscle group. Resistance that varies with joint angle can be achieved with isokinetic devices in which angular velocity is held constant and variable torque is generated when the patient attempts to move faster than the device but are ineffective if a patient cannot generate torque rapidly. In this paper, we report the development of a versatile rehabilitation device that can be used to strengthen different muscle groups based on the torque generating capability of the muscle that changes with joint angle. The device is low cost, is smaller than other commercially available machines, and can be programmed to apply resistance that is unique to a particular patient and that will optimize strengthening. The core of the device, a damper with smart magnetorheological fluids, provides passive exercise force. A digital adaptive control is capable of regulating exercise force precisely following the muscle strengthening profile prescribed by a physical therapist. The device could be programmed with artificial intelligence to dynamically adjust the target force profile to optimize rehabilitation effects. The device provides both isometric and isokinetic strength training and can be developed into a small, low-cost device that may be capable of providing optimal strengthening in the home.

  20. Pair creation at large inherent angles

    International Nuclear Information System (INIS)

    Chen, P.; Tauchi, T.; Schroeder, D.V.

    1992-01-01

    In the next-generation linear colliders, the low-energy e + e - pairs created during the collision of high-energy e + e - beams would cause potential deleterious background problems to the detectors. At low collider energies, the pairs are made essentially by the incoherent process, where the pair is created by the interaction of beamstrahlung photons on the individual particles in the oncoming beam. This problem was first identified by Zolotarev, et al. At energies where the beamstrahlung parameter Υ lies approximately in the range 0.6 approx-lt Υ approx-lt 100, pair creation from the beamstrahlung photons is dominated by a coherent process, first noted by Chen. The seriousness of this pair creation problem lies in the transverse momenta that the pair particles carry when leaving the interaction point (IP) with large angles. Since the central issue is the transverse momentum for particles with large angles, the authors notice that there is another source for it. Namely, when the pair particles are created at low energies, the intrinsic angles of these pairs when produced may already be large. In this paper they reinvestigate the problem, following essentially the same equivalent photon approach, but with changes in specific details including the virtual photon spectrum. In addition, various assumptions are made more explicit. The formulas derived are then applied to the collider parameters designed by Palmer

  1. Measurement of Critical Contact Angle in a Microgravity Space Experiment

    Science.gov (United States)

    Concus, P.; Finn, R.; Weislogel, M.

    1998-01-01

    Mathematical theory predicts that small changes in container shape or in contact angle can give rise to large shifts of liquid in a microgravity environment. This phenomenon was investigated in the Interface Configuration Experiment on board the USMT,2 Space Shuttle flight. The experiment's "double proboscis" containers were designed to strike a balance between conflicting requirements of sizable volume of liquid shift (for ease of observation) and abruptness of the shift (for accurate determination of critical contact angle). The experimental results support the classical concept of macroscopic contact angle and demonstrate the role of hysteresis in impeding orientation toward equilibrium.

  2. Optimal fringe angle selection for digital fringe projection technique.

    Science.gov (United States)

    Wang, Yajun; Zhang, Song

    2013-10-10

    Existing digital fringe projection (DFP) systems mainly use either horizontal or vertical fringe patterns for three-dimensional shape measurement. This paper reveals that these two fringe directions are usually not optimal where the phase change is the largest to a given depth variation. We propose a novel and efficient method to determine the optimal fringe angle by projecting a set of horizontal and vertical fringe patterns onto a step-height object and by further analyzing two resultant phase maps. Experiments demonstrate the existence of the optimal angle and the success of the proposed optimal angle determination method.

  3. A simple algorithm for calculating the scattering angle in atomic collisions

    International Nuclear Information System (INIS)

    Belchior, J.C.; Braga, J.P.

    1996-01-01

    A geometric approach to calculate the classical atomic scattering angle is presented. The trajectory of the particle is divided into several straight-lines and changing in direction from one sector to the other is used to calculate the scattering angle. In this model, calculation of the scattering angle does not involve either the direct evaluation of integrals nor classical turning points. (author)

  4. Current diagnosis of tumors developed in the internal auditory canal and cerebellopontine angle

    International Nuclear Information System (INIS)

    Vignaud, J.; Doyon, D.

    1988-01-01

    The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle [fr

  5. Comparison of different passive knee extension torque-angle assessments

    International Nuclear Information System (INIS)

    Freitas, Sandro R; Vaz, João R; Bruno, Paula M; Valamatos, Maria J; Mil-Homens, Pedro

    2013-01-01

    Previous studies have used isokinetic dynamometry to assess joint torques and angles during passive extension of the knee, often without reporting upon methodological errors and reliability outcomes. In addition, the reliability of the techniques used to measure passive knee extension torque-angle and the extent to which reliability may be affected by the position of the subjects is also unclear. Therefore, we conducted an analysis of the intra- and inter-session reliability of two methods of assessing passive knee extension: (A) a 2D kinematic analysis coupled to a custom-made device that enabled the direct measurement of resistance to stretch and (B) an isokinetic dynamometer used in two testing positions (with the non-tested thigh either flexed at 45° or in the neutral position). The intra-class correlation coefficients (ICCs) of torque, the slope of the torque-angle curve, and the parameters of the mathematical model that were fit to the torque-angle data for the above conditions were measured in sixteen healthy male subjects (age: 21.4 ± 2.1 yr; BMI: 22.6 ± 3.3 kg m −2 ; tibial length: 37.4 ± 3.4 cm). The results found were: (1) methods A and B led to distinctly different torque-angle responses; (2) passive torque-angle relationship and stretch tolerance were influenced by the position of the non-tested thigh; and (3) ICCs obtained for torque were higher than for the slope and for the mathematical parameters that were fit to the torque-angle curve. In conclusion, the measurement method that is used and the positioning of subjects can influence the passive knee extension torque-angle outcome. (paper)

  6. Improved light extraction from white organic light-emitting devices using a binary random phase array

    Energy Technology Data Exchange (ETDEWEB)

    Inada, Yasuhisa, E-mail: inada.yasuhisa@jp.panasonic.com; Nishiwaki, Seiji; Hirasawa, Taku; Nakamura, Yoshitaka; Hashiya, Akira; Wakabayashi, Shin-ichi; Suzuki, Masa-aki [R and D Division, Panasonic Corporation, 1006 Kadoma, Kadoma City, Osaka 571-8501 (Japan); Matsuzaki, Jumpei [Device Development Center, Eco Solutions Company, Panasonic Corporation, 1048 Kadoma, Osaka 571-8686 Japan (Japan)

    2014-02-10

    We have developed a binary random phase array (BRPA) to improve the light extraction performance of white organic light-emitting devices (WOLEDs). We demonstrated that the scattering of incoming light can be controlled by employing diffraction optics to modify the structural parameters of the BRPA. Applying a BRPA to the substrate of the WOLED leads to enhanced extraction efficiency and suppression of angle-dependent color changes. Our systematic study clarifies the effect of scattering on the light extraction of WOLEDs.

  7. Improved light extraction from white organic light-emitting devices using a binary random phase array

    International Nuclear Information System (INIS)

    Inada, Yasuhisa; Nishiwaki, Seiji; Hirasawa, Taku; Nakamura, Yoshitaka; Hashiya, Akira; Wakabayashi, Shin-ichi; Suzuki, Masa-aki; Matsuzaki, Jumpei

    2014-01-01

    We have developed a binary random phase array (BRPA) to improve the light extraction performance of white organic light-emitting devices (WOLEDs). We demonstrated that the scattering of incoming light can be controlled by employing diffraction optics to modify the structural parameters of the BRPA. Applying a BRPA to the substrate of the WOLED leads to enhanced extraction efficiency and suppression of angle-dependent color changes. Our systematic study clarifies the effect of scattering on the light extraction of WOLEDs

  8. Multi-angle compound imaging

    DEFF Research Database (Denmark)

    Jespersen, Søren Kragh; Wilhjelm, Jens Erik; Sillesen, Henrik

    1998-01-01

    This paper reports on a scanning technique, denoted multi-angle compound imaging (MACI), using spatial compounding. The MACI method also contains elements of frequency compounding, as the transmit frequency is lowered for the highest beam angles in order to reduce grating lobes. Compared to conve......This paper reports on a scanning technique, denoted multi-angle compound imaging (MACI), using spatial compounding. The MACI method also contains elements of frequency compounding, as the transmit frequency is lowered for the highest beam angles in order to reduce grating lobes. Compared...... to conventional B-mode imaging MACI offers better defined tissue boundaries and lower variance of the speckle pattern, resulting in an image with reduced random variations. Design and implementation of a compound imaging system is described, images of rubber tubes and porcine aorta are shown and effects...... on visualization are discussed. The speckle reduction is analyzed numerically and the results are found to be in excellent agreement with existing theory. An investigation of detectability of low-contrast lesions shows significant improvements compared to conventional imaging. Finally, possibilities for improving...

  9. Femoral varus: what's the angle

    DEFF Research Database (Denmark)

    Miles, James Edward; Svalastoga, Eiliv Lars; Eriksen, Thomas

    angles were calculated using Microsoft Excel for the three previously reported techniques and a novel method, which we believed would be more reliable. Reliability between readings was assessed using the within-subject standard deviation and repeatability coefficient, and the effect of angulation...

  10. Effect of stifle angle on the magnitude of the tibial plateau angle measurement in dogs with intact and transected cranial cruciate ligament. A cadaveric study.

    Science.gov (United States)

    Aulakh, K S; Harper, T A M; Lanz, O I; Daniel, G B; Werre, S R

    2011-01-01

    To determine the effect of stifle angle on the magnitude of the radiographic tibial plateau angle (TPA) in normal and cranial cruciate ligament (CCL) -deficient stifles. Three pairs of canine cadaver hindlimbs from three skeletally mature dogs were positioned in a custom-made positioning device. A lateral radiograph of each specimen was obtained before and after transection of the CCL at four stifle angles (90°, 110°, 135° and 140-150° [i.e. maximum extension]), based on goniometric measurements. Four observers determined the radiographic TPA twice for each radiograph with a minimum of two days between each measurement. The radiographic TPA measurements in all specimens at different stifle angles with intact CCL and transected CCL were compared with mixed-model ANOVA. The effect of stifle angle, CCL transection, and interaction between the two on observer TPA measurement variability was also determined using the coefficient of variation. Tibial plateau angle was not statistically different in the stifle angles for either the intact or transected CCL. There was also no statistical difference for TPA between intact and transected CCL groups at each of the stifle angles. Stifle angle, CCL transection and interaction between the two did not have any significant effect for intra-observer and inter-observer variation. The angle of the stifle during radiography does not influence the magnitude of the TPA measurement as determined on true lateral radiographs of the stifle and tibia in cadaveric canine limbs.

  11. Sealing device

    Science.gov (United States)

    Garcia-Crespo, Andres Jose

    2013-12-10

    A sealing device for sealing a gap between a dovetail of a bucket assembly and a rotor wheel is disclosed. The sealing device includes a cover plate configured to cover the gap and a retention member protruding from the cover plate and configured to engage the dovetail. The sealing device provides a seal against the gap when the bucket assemply is subjected to a centrifugal force.

  12. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  13. Gauging device

    International Nuclear Information System (INIS)

    Qurnell, F.D.; Patterson, C.B.

    1979-01-01

    A gauge supporting device for measuring say a square tube comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a compression member or members. The tensioned guides provide planes of reference for measuring devices moved therealong on a carriage. The device is especially useful for making on site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (UK)

  14. Support and maneuvering device

    Science.gov (United States)

    Wood, R.L.

    1987-03-23

    A support and maneuvering device includes an elongated flexible inflatable enclosure having a fixed end and a movable end. The movable end is collapsible toward the fixed end to a contracted position when the enclosure is in a noninflated condition. Upon inflation, the movable end is movable away from the fixed end to an extended position. The movable end includes means for mounting an article such as a solar reflector thereon. The device also includes a plurality of position controlling means disposed about the movable end to effect adjusting movement of portions thereof by predetermined amounts and for controlling an angle at which the article disposed at the movable end is oriented. The plurality of position controlling means limits a suitable number degrees of freedom of the movable end for transmitting a steering motion thereto and for controlling the position thereof. 9 figs.

  15. The impact of changing antiseptic skin preparation agent used for cardiac implantable electronic device (CIED) procedures on the risk of infection.

    Science.gov (United States)

    Qintar, Mohammed; Zardkoohi, Omeed; Hammadah, Muhammad; Hsu, Amy; Wazni, Oussama; Wilkoff, Bruce L; Tarakji, Khaldoun G

    2015-02-01

    Cardiac implantable electronic device (CIED) infection is a major complication that is associated with increased morbidity and mortality. Recent data suggested a relationship between the antiseptic agent used for skin preparation at time of CIED procedure and risk for infection. On April 30, 2011, we changed the antiseptic agent used for skin preparation at our tertiary care facility from chlorhexidine-alcohol to povidone-iodine for all CIED procedures. We retrospectively reviewed records of all patients who underwent CIED procedure 1 year before and after the change. CIED infection was defined as pocket or endovascular systemic infection that required removal within 1 year of the index procedure. We examined if the change affected the risk of CIED infection. A total of 2,792 patients underwent 2,840 CIED procedures; 1,748 (61.5%) had implantable cardioverter defibrillator procedures and 1,092 (38.4%) had permanent pacemaker procedures. Chlorhexidine-alcohol agent was used in 1,450 (51.1%) procedures, and povidone-iodine agent was used in 1,390 (48.9%). After 1 year of follow-up, 31 patients (1.09%) developed CIED infection that required system removal. The 1-year infection rate was 1.1% among both antiseptic agent groups and there were no significant differences in the infection presentations among both groups (P = 0.950). Multivariate Cox proportional hazards regression model showed that risk factors for infection within 1 year included age, diabetes, and African American race. In one large cohort of patients undergoing CIED procedures, the antiseptic agent used for skin preparation (chlorhexidine-alcohol vs povidone-iodine) was not associated with increased risk of developing CIED infection. ©2014 Wiley Periodicals, Inc.

  16. Improvement of reliability and speed of phase change memory devices with N7.9(Ge46.9Bi7.2Te45.9 films

    Directory of Open Access Journals (Sweden)

    J. H. Park

    2015-08-01

    Full Text Available In this study, we propose a nitrogen-incorporated GeBiTe ternary phase of N7.9(Ge46.9Bi7.2Te45.9 as a phase change material for reliable PCM (Phase Change Memory with high speed operation. We found that the N7.9(Ge46.9Bi7.2Te45.9 film shows the resistance value of 40 kΩ after annealing at 440oC for 10 minutes, which is much higher than the value of 3.4 kΩ in the case of conventional N7.0(Ge22.0Sb22.0Te56.0 films. A set operation time of 14 nsec was achieved in the devices due to the increased probability of the nucleation by the addition of the elemental Bi. The long data retention time of 10 years at 85oC on the base of 1% failure was obtained as the result of higher activation energy of 2.52 eV for the crystallization compared to the case of N7.0(Ge22.0Sb22.0Te56.0 film, in which the activation energy is 2.1 eV. In addition, a reset current reduction of 27% and longer cycles of endurance as much as 2 order of magnitude compared to the case of N7.0(Ge22.0Sb22.0Te56.0 were observed at a set operation time of 14 nsec. Our results show that N7.9(Ge46.9Bi7.2Te45.9 is highly promising for use as a phase change material in reliable PCMs with high performance and also in forthcoming storage class memory applications, too.

  17. Improvement of reliability and speed of phase change memory devices with N7.9(Ge46.9Bi7.2Te45.9) films

    Science.gov (United States)

    Park, J. H.; Kim, S.-W.; Kim, J. H.; Ko, D.-H.; Wu, Z.; Cho, S. L.; Ahn, D.; Ahn, D. H.; Lee, J. M.; Nam, S. W.

    2015-08-01

    In this study, we propose a nitrogen-incorporated GeBiTe ternary phase of N7.9(Ge46.9Bi7.2Te45.9) as a phase change material for reliable PCM (Phase Change Memory) with high speed operation. We found that the N7.9(Ge46.9Bi7.2Te45.9) film shows the resistance value of 40 kΩ after annealing at 440oC for 10 minutes, which is much higher than the value of 3.4 kΩ in the case of conventional N7.0(Ge22.0Sb22.0Te56.0) films. A set operation time of 14 nsec was achieved in the devices due to the increased probability of the nucleation by the addition of the elemental Bi. The long data retention time of 10 years at 85oC on the base of 1% failure was obtained as the result of higher activation energy of 2.52 eV for the crystallization compared to the case of N7.0(Ge22.0Sb22.0Te56.0) film, in which the activation energy is 2.1 eV. In addition, a reset current reduction of 27% and longer cycles of endurance as much as 2 order of magnitude compared to the case of N7.0(Ge22.0Sb22.0Te56.0) were observed at a set operation time of 14 nsec. Our results show that N7.9(Ge46.9Bi7.2Te45.9) is highly promising for use as a phase change material in reliable PCMs with high performance and also in forthcoming storage class memory applications, too.

  18. Development of scanning micromirror with discrete steering angles

    International Nuclear Information System (INIS)

    Wang, Z F; Noell, W; Zickar, M; Rooij, N F de; Lim, S P

    2006-01-01

    This paper describes the development of a new MEMS-based optical mirror, which can perform optical switching (or scanning) function with discrete reflection angles in an outof- plane configuration. The device is fabricated through the Deep Reactive Ion Etching (DRIE) process on silicon-on-insulator (SOI) wafer, followed by wafer dicing and assembly with two metalised glass dies. The MEMS mirror can be tilted under electrostatic force between the opposite electrodes embedded on SOI and glass structures. The most outstanding feature of this MEMS mirror is the discrete and therefore, reliable tilting angles, which generated by its unique mechanical structural design and electrostatic-driven mechanism. In this paper, the concept of the new scanning mirror is presented, followed by the introduction of device design, mechanical simulation, microfabrication process, assembly solution, and some testing results. The potential applications of this new MEMS mirror include optical scanning, optical sensing (or detection), and optical switching

  19. Device for contamination monitoring against radiation contamination of people

    International Nuclear Information System (INIS)

    Rische, U.W.; Gerlach, R.

    1986-01-01

    The monitor has detector devices at an angle to each other made as a rigid component which can be rotated around a vertical axis in the angle between the joined detector devices. A reset drive which can be tensioned is provided at the axis of rotation. If it is in its rest position, a platform is situated as floor plate with a foot detector between the vertical detector devices. (orig./HP) [de

  20. Application and development of non contact angle-wide viewing system in vitreous retinal surgery

    Directory of Open Access Journals (Sweden)

    Rong-Hua He

    2016-07-01

    Full Text Available Wide-angle viewing system as an important auxiliary device can clearly observe the whole fundus field of vision in vitreous surgery, which enable vitreoretinal surgery more efficient, safer and more effective. So it has very high application value in ophthalmologic operation. In this paper, we studied the development and application of wide-angle viewing system in vitreoretinal surgery in recent years, from which we summed up the advantage of non-contact wide-angle viewing system in clinical field, and pointed out the shortcomings. The ultimate goal is to make the non-contact wide-angle viewing system better applied in vitreous surgery.

  1. Side effects of intraoral devices for OSAS treatment.

    Science.gov (United States)

    Teixeira, Andressa Otranto de Britto; Andrade, Ana Luiza Ladeia; Almeida, Rhita Cristina da Cunha; Almeida, Marco Antonio de Oliveira

    2017-10-14

    Intraoral devices have increasingly assumed a key role in the treatment of obstructive sleep apnea syndrome, but there are limitations to their indication and side effects that result from their continuous use, as well as the use of the continuous positive airway pressure device. To evaluate the changes in dental positioning caused by the continuous use of mandibular advancement devices. A prospective longitudinal study with a sample of 15 patients, with evaluation of complete documentation after a mean time of 6.47 months, assessed changes in dental positioning due to the use of the Twin Block oral device for the treatment of patients with apnea. The following variables were evaluated: overjet, overbite, upper and lower intermolar distances, upper and lower intercanine distances, Little's irregularity index and the incisor mandibular plane angle. An intraclass correlation test was performed and a correlation index>0.08 was accepted. After verifying the normal sample distribution (Shapiro-Wilks), a parametric test was used (t test), with a significance level set at 5%. There was a decrease in the values of overjet, overbite and Little's irregularity index, whereas there was an increase in the lower intercanine distance and IMPA values. All these variables are influenced, at different levels, by the forward inclination of the lower incisors, an action that can be expected due to the force applied by the device on the dentition. The other variables did not show statistically significant differences. After a mean time of 6.47 months of use of the mandibular advancement device, there were statistically significant changes in the dental positioning, but they were not clinically relevant. However, it is relevant that this device is commonly in use over long periods of time, making the monitoring of these patients of the utmost importance for the duration of their therapy. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia C

  2. Fusion devices

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1977-01-01

    Three types of thermonuclear fusion devices currently under development are reviewed for an electric utilities management audience. Overall design features of laser fusion, tokamak, and magnetic mirror type reactors are described and illustrated. Thrusts and trends in current research on these devices that promise to improve performance are briefly reviewed. Twenty photographs and drawings are included

  3. BRAKE DEVICE

    Science.gov (United States)

    O'Donnell, T.J.

    1959-03-10

    A brake device is described for utilization in connection with a control rod. The device comprises a pair of parallelogram link mechanisms, a control rod moveable rectilinearly therebetween in opposite directions, and shoes resiliently supported by the mechanism for frictional engagement with the control rod.

  4. PLASMA DEVICE

    Science.gov (United States)

    Gow, J.D.; Wilcox, J.M.

    1961-12-26

    A device is designed for producing and confining highenergy plasma from which neutrons are generated in copious quantities. A rotating sheath of electrons is established in a radial electric field and axial magnetic field produced within the device. The electron sheath serves as a strong ionizing medium to gas introdueed thereto and also functions as an extremely effective heating mechanism to the resulting plasma. In addition, improved confinement of the plasma is obtained by ring magnetic mirror fields produced at the ends of the device. Such ring mirror fields are defined by the magnetic field lines at the ends of the device diverging radially outward from the axis of the device and thereafter converging at spatial annular surfaces disposed concentrically thereabout. (AFC)

  5. Disorders of the cerebellopontine angle

    International Nuclear Information System (INIS)

    Block, F.

    2006-01-01

    Disorders of the cerebellopontine angle may present by symptoms like vertigo, hearing problems, affection of the trigeminal or facial nerve. Ipsilateral ataxia and contralateral hemiparesis develop in case of a rather large tumor in this region and display an involvement of the cerebellum and/or brainstem. However, some of these typical symptoms are not recognized by the patient. Thus, in case of a suspicion of a disorder of the cerebellopontine angle the relevant functions have to be tested clinically. In addition, electrophysiology can confirm dysfunction of these cranial nerves. Mainstay of the therapy should be the treatment of the underlying cause. Nevertheless, not seldom it is necessary to treat symptoms like vertigo or facial pain. (orig.) [de

  6. Measurement of the angle gamma

    International Nuclear Information System (INIS)

    Aleksan, R.; Kayser, B.; Sphicas, P.

    1993-01-01

    The angle γ at least as defined in the Wolfenstein approximation is not completely out of reach of current or proposed dedicated B experiments. This conclusion certainly depends crucially on the assumed trigger and tagging efficiencies and also on the expected backgrounds. The work summarized here represents but a first step in the direction of extracting the third angle of the unitarity triangle. The theoretical developments during the workshop have resulted in a clearer understanding of the quantities studied. On the experimental side, new decay modes (i.e. in addition to the traditional ρK s decay) have resulted in expections for observing CP violation in B s decays which are not unreasonable. It is conceivable that a dedicated B experiment can probe a fundamental aspect of the Standard Model, the CKM matrix, in multiple ways. In the process, new physics can appear anywhere along the line

  7. Fuel pattern recognition device

    International Nuclear Information System (INIS)

    Sato, Tomomi.

    1995-01-01

    The device of the present invention monitors normal fuel exchange upon fuel exchanging operation carried out in a reactor of a nuclear power plant. Namely, a fuel exchanger is movably disposed to the upper portion of the reactor and exchanges fuels. An exclusive computer receives operation signals of the fuel exchanger during operation as inputs, and outputs reactor core fuel pattern information signals to a fuel arrangement diagnosis device. An underwater television camera outputs image signals of a fuel pattern in the reactor core to an image processing device. If there is any change in the image signals for the fuel pattern as a result of the fuel exchange operation of the fuel exchanger, the image processing device outputs the change as image signals to the fuel pattern diagnosis device. The fuel pattern diagnosis device compares the pattern information signals from the exclusive computer with the image signals from the image processing device, to diagnose the result of the fuel exchange operation performed by the fuel exchanger and inform the diagnosis by means of an image display. (I.S.)

  8. LHC Report: playing with angles

    CERN Multimedia

    Mike Lamont for the LHC team

    2016-01-01

    Ready (after a machine development period), steady (running), go (for a special run)!   The crossing angles are an essential feature of the machine set-up. They have to be big enough to reduce the long-range beam-beam effect. The LHC has recently enjoyed a period of steady running and managed to set a new record for “Maximum Stable Luminosity Delivered in 7 days” of 3.29 fb-1 between 29 August and 4 September. The number of bunches per beam remains pegged at 2220 because of the limitations imposed by the SPS beam dump. The bunch population is also somewhat reduced due to outgassing near one of the injection kickers at point 8. Both limitations will be addressed during the year-end technical stop, opening the way for increased performance in 2017. On 10 and 11 September, a two day machine development (MD) period took place. The MD programme included a look at the possibility of reducing the crossing angle at the high-luminosity interaction points. The crossing angles are an ess...

  9. Powering biomedical devices

    CERN Document Server

    Romero, Edwar

    2013-01-01

    From exoskeletons to neural implants, biomedical devices are no less than life-changing. Compact and constant power sources are necessary to keep these devices running efficiently. Edwar Romero's Powering Biomedical Devices reviews the background, current technologies, and possible future developments of these power sources, examining not only the types of biomedical power sources available (macro, mini, MEMS, and nano), but also what they power (such as prostheses, insulin pumps, and muscular and neural stimulators), and how they work (covering batteries, biofluids, kinetic and ther

  10. Anomalous and resonance small-angle scattering

    International Nuclear Information System (INIS)

    Epperson, J.E.; Thiyagarajan, P.

    1988-01-01

    Significant changes in the small-angle scattered intensity can be induced by making measurements with radiation close to an absorption edge of an appropriate atomic species contained in the sample. These changes can be related quantitatively to the real and imaginary anomalous-dispersion terms for the scattering factor (X-rays) or scattering length (neutrons). The physics inherent in these anomalous-dispersion terms is first discussed before consideration of how they enter the relevant scattering theory. Two major areas of anomalous-scattering research have emerged; macromolecules in solution and unmixing of metallic alloys. Research in each area is reviewed, illustrating both the feasibility and potential of these techniques. All the experimental results reported to date have been obtained with X-rays. However, it is pointed out that the formalism is the same for the analog experiment with neutrons, and a number of suitable isotopes exist which exhibit resonance in an accessible range of energy. Potential applications of resonance small-angle neutron scattering are discussed. (orig.)

  11. Increasing efficacy of graminicides with a forward angled spray

    DEFF Research Database (Denmark)

    Jensen, Peter Kryger

    2012-01-01

    Control of annual grass species with vertically oriented leaves in agricultural crops by application of foliar acting herbicides with conventional hydraulic sprayers can be increased using forward angled nozzles. Changing the spray angle from the normally predominantly vertical spray towards...... an angled spray increases the potential target size of vertically oriented targets. This theory was tested in field experiments from 2005 to 2009 investigating control of three different grass species and a dicotyledonous weed species at early growth stages using foliar acting herbicides. Lolium perenne...... efficacy on L. perenne at early growth stages using nozzles with different spray quality, at different driving speeds and in different wind conditions. Similarly graminicide efficacy was increased when nozzles were angled 60° forward controlling A. myosuroides. Experiments investigating control of the two...

  12. Angle-dependent magnetoresistance and quantum oscillations in high-mobility semimetal LuPtBi

    KAUST Repository

    Xu, Guizhou; Hou, Zhipeng; Wang, Yue; Zhang, Xiaoming; Zhang, Hongwei; Liu, Enke; Xi, X; Xu, Feng; Wu, Guangheng; Zhang, Xixiang; Wang, Wenhong

    2017-01-01

    The recent discovery of ultrahigh mobility and large positive magnetoresistance in topologically non-trivial Half-Heusler semimetal LuPtBi provides a unique playground for studying exotic physics and significant perspective for device applications. As an fcc-structured electron-hole-compensated semimetal, LuPtBi theoretically exhibits six symmetrically arranged anisotropic electron Fermi pockets and two nearly-spherical hole pockets, offering the opportunity to explore the physics of Fermi surface with a simple angle-related magnetotransport properties. In this work, through the angle-dependent transverse magnetoresistance measurements, in combination with high-field SdH quantum oscillations, we achieved to map out a Fermi surface with six anisotropic pockets in the high-temperature and low-field regime, and furthermore, identify a possible magnetic field driven Fermi surface change at lower temperatures. Reasons account for the Fermi surface change in LuPtBi are discussed in terms of the field-induced electron evacuation due to Landau quantization.

  13. Angle-dependent magnetoresistance and quantum oscillations in high-mobility semimetal LuPtBi

    KAUST Repository

    Xu, Guizhou

    2017-03-14

    The recent discovery of ultrahigh mobility and large positive magnetoresistance in topologically non-trivial Half-Heusler semimetal LuPtBi provides a unique playground for studying exotic physics and significant perspective for device applications. As an fcc-structured electron-hole-compensated semimetal, LuPtBi theoretically exhibits six symmetrically arranged anisotropic electron Fermi pockets and two nearly-spherical hole pockets, offering the opportunity to explore the physics of Fermi surface with a simple angle-related magnetotransport properties. In this work, through the angle-dependent transverse magnetoresistance measurements, in combination with high-field SdH quantum oscillations, we achieved to map out a Fermi surface with six anisotropic pockets in the high-temperature and low-field regime, and furthermore, identify a possible magnetic field driven Fermi surface change at lower temperatures. Reasons account for the Fermi surface change in LuPtBi are discussed in terms of the field-induced electron evacuation due to Landau quantization.

  14. Significant issues and changes for ANSI/ASME OM-1 1981, part 1, ASME OMc code-1994, and ASME OM Code-1995, Appendix I, inservice testing of pressure relief devices in light water reactor power plants

    Energy Technology Data Exchange (ETDEWEB)

    Seniuk, P.J.

    1996-12-01

    This paper identifies significant changes to the ANSI/ASME OM-1 1981, Part 1, and ASME Omc Code-1994 and ASME OM Code-1995, Appendix I, {open_quotes}Inservice Testing of Pressure Relief Devices in Light-Water Reactor Power Plants{close_quotes}. The paper describes changes to different Code editions and presents insights into the direction of the code committee and selected topics to be considered by the ASME O&M Working Group on pressure relief devices. These topics include scope issues, thermal relief valve issues, as-found and as-left set-pressure determinations, exclusions from testing, and cold setpoint bench testing. The purpose of this paper is to describe some significant issues being addressed by the O&M Working Group on Pressure Relief Devices (OM-1). The writer is currently the chair of OM-1 and the statements expressed herein represents his personal opinion.

  15. Significant issues and changes for ANSI/ASME OM-1 1981, part 1, ASME OMc code-1994, and ASME OM Code-1995, Appendix I, inservice testing of pressure relief devices in light water reactor power plants

    International Nuclear Information System (INIS)

    Seniuk, P.J.

    1996-01-01

    This paper identifies significant changes to the ANSI/ASME OM-1 1981, Part 1, and ASME Omc Code-1994 and ASME OM Code-1995, Appendix I, open-quotes Inservice Testing of Pressure Relief Devices in Light-Water Reactor Power Plantsclose quotes. The paper describes changes to different Code editions and presents insights into the direction of the code committee and selected topics to be considered by the ASME O ampersand M Working Group on pressure relief devices. These topics include scope issues, thermal relief valve issues, as-found and as-left set-pressure determinations, exclusions from testing, and cold setpoint bench testing. The purpose of this paper is to describe some significant issues being addressed by the O ampersand M Working Group on Pressure Relief Devices (OM-1). The writer is currently the chair of OM-1 and the statements expressed herein represents his personal opinion

  16. Sealing devices

    International Nuclear Information System (INIS)

    Coulson, R.A.

    1980-01-01

    A sealing device for minimising the leakage of toxic or radioactive contaminated environments through a biological shield along an opening through which a flexible component moves that penetrates the shield. The sealing device comprises an outer tubular member which extends over a length not less than the maximum longitudinal movement of the component along the opening. An inner sealing block is located intermediate the length of the component by connectors and is positioned in the bore of the outer tubular member to slide in the bore and effect a seal over the entire longitudinal movement of the component. The cross-section of the device may be circular and the block may be of polytetrafluoroethylene or of nylon impregnated with molybdenum or may be metallic. A number of the sealing devices may be combined into an assembly for a plurality of adjacent longitudinally movable components, each adapted to sustain a tensile load, providing the various drives of a master-slave manipulator. (author)

  17. Highly efficient inverted top emitting organic light emitting diodes using a transparent top electrode with color stability on viewing angle

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung-Bum; Lee, Jeong-Hwan; Moon, Chang-Ki; Kim, Jang-Joo, E-mail: jjkim@snu.ac.kr [Department of Materials Science and Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of)

    2014-02-17

    We report a highly efficient phosphorescent green inverted top emitting organic light emitting diode with excellent color stability by using the 1,4,5,8,9,11-hexaazatriphenylene-hexacarbonitrile/indium zinc oxide top electrode and bis(2-phenylpyridine)iridium(III) acetylacetonate as the emitter in an exciplex forming co-host system. The device shows a high external quantum efficiency of 23.4% at 1000 cd/m{sup 2} corresponding to a current efficiency of 110 cd/A, low efficiency roll-off with 21% at 10 000 cd/m{sup 2} and low turn on voltage of 2.4 V. Especially, the device showed very small color change with the variation of Δx = 0.02, Δy = 0.02 in the CIE 1931 coordinates as the viewing angle changes from 0° to 60°. The performance of the device is superior to that of the metal/metal cavity structured device.

  18. Ferroelectric devices

    CERN Document Server

    Uchino, Kenji

    2009-01-01

    Updating its bestselling predecessor, Ferroelectric Devices, Second Edition assesses the last decade of developments-and setbacks-in the commercialization of ferroelectricity. Field pioneer and esteemed author Uchino provides insight into why this relatively nascent and interdisciplinary process has failed so far without a systematic accumulation of fundamental knowledge regarding materials and device development.Filling the informational void, this collection of information reviews state-of-the-art research and development trends reflecting nano and optical technologies, environmental regulat

  19. Feasibility of studying large p/sub perpendicular to/ in ISABELLE's wide-angle hall

    International Nuclear Information System (INIS)

    Aronson, S.; Danby, G.; Engelmann, R.; Foley, K.; McCarthy, R.; Paige, F.; Pope, B.; Thorndike, A.

    1979-01-01

    The experimental area at 6 o'clock in the present ISABELLE site plan has a configuration suitable for studying particles produced at large angles relative to the beam lines. It is natural to think of housing a program of large p/perpendicular to/ studies in this area. A particular device has been considered, namely a pair of multiparticle spectrometers back-to-back at 90 0 to the beams, as a vehicle for carrying out this program. Enough details are presented to allow for a reasonable test of the planned 6 o'clock area as a site for such experiments. In summer, this study shows that a rather ambitious program of experiments can be performed in this area with some relatively easily implemented changes in the hall design

  20. Small angle scattering and polymers

    International Nuclear Information System (INIS)

    Cotton, J.P.

    1996-01-01

    The determination of polymer structure is a problem of interest for both statistical physics and industrial applications. The average polymer structure is defined. Then, it is shown why small angle scattering, associated with isotopic substitution, is very well suited to the measurement of the chain conformation. The corresponding example is the old, but pedagogic, measurement of the chain form factor in the polymer melt. The powerful contrast variation method is illustrated by a recent determination of the concentration profile of a polymer interface. (author) 12 figs., 48 refs

  1. Ultrasonic sensor for sodium perspective device

    International Nuclear Information System (INIS)

    Ogawa, Fujio; Onuki, Koji.

    1995-01-01

    The present invention concerns an ultrasonic wave sensor for a sodium perspective device disposed in an FBR type reactor, which can change the directing angle of the ultrasonic sensor irrespective of the external conditions in liquid sodium. Namely, the sensor comprises (1) a sensor main body, (2) a diaphragm disposed on an oscillating surface of ultrasonic waves generated from the sensor main body, (3) a pressurizing and depressurizing nozzle connected to the sensor main body, and (4) a pressure detector disposed to these nozzles. A gas is charged/discharged to and from the sensor main body to control a gas pressure in the main body. If the gas pressure is made higher, the diaphragm is deformed convexly. If the gas pressure is lowered, the diaphragm is deformed concavely. The directing angle is greater when it is deformed a convexly, and it is smaller when it is deformed concavely. Accordingly, ultrasonic wave receiving/sending range in the sodium can be varied optionally by controlling the gas pressure in the main body. (I.S.)

  2. Effect of incidence angle on the wake turbulence of a turbine rotor blade

    International Nuclear Information System (INIS)

    Chang, Sung Il; Lee, Sang Woo

    2005-01-01

    This paper describes effects of incidence angle on the wake turbulent flow of a high-turning turbine rotor blade. For three incidence angles of -5, 0 and 5 degrees, energy spectra as well as profiles of mean velocity magnitude and turbulence intensity at mid-span are reported in the wake. Vortex shedding frequencies are obtained from the energy spectra. The result shows that as the incidence angle changes from -5 to 5 degrees, the suction-side wake tends to be widened and the deviation angle is increased. Strouhal numbers based on the shedding frequencies have a nearly constant value, regardless of the tested incidence angles

  3. A LEGO Mindstorms Brewster angle microscope

    Science.gov (United States)

    Fernsler, Jonathan; Nguyen, Vincent; Wallum, Alison; Benz, Nicholas; Hamlin, Matthew; Pilgram, Jessica; Vanderpoel, Hunter; Lau, Ryan

    2017-09-01

    A Brewster Angle Microscope (BAM) built from a LEGO Mindstorms kit, additional LEGO bricks, and several standard optics components, is described. The BAM was built as part of an undergraduate senior project and was designed, calibrated, and used to image phospholipid, cholesterol, soap, and oil films on the surface of water. A BAM uses p-polarized laser light reflected off a surface at the Brewster angle, which ideally yields zero reflectivity. When a film of different refractive index is added to the surface a small amount of light is reflected, which can be imaged in a microscope camera. Films of only one molecule (approximately 1 nm) thick, a monolayer, can be observed easily in the BAM. The BAM was used in a junior-level Physical Chemistry class to observe phase transitions of a monolayer and the collapse of a monolayer deposited on the water surface in a Langmuir trough. Using a photometric calculation, students observed a change in thickness of a monolayer during a phase transition of 7 Å, which was accurate to within 1 Å of the value determined by more advanced methods. As supplementary material, we provide a detailed manual on how to build the BAM, software to control the BAM and camera, and image processing software.

  4. An Angle Criterion for Riesz Bases

    DEFF Research Database (Denmark)

    Lindner, Alexander M; Bittner, B.

    1999-01-01

    We present a characterization of Riesz bases in terms ofthe angles between certain finite dimensional subspaces. Correlationsbetween the bounds of the Riesz basis and the size of the angles arederived....

  5. Ion implantation in advanced planar and vertical devices

    International Nuclear Information System (INIS)

    Gossmann, Hans-Joachim L.

    2005-01-01

    The extent ('gate overlap') and slope ('abruptness') of the lateral junction are quickly replacing vertical junction depth as the most important physical junction metrics in advanced device architectures. This is in particular true for ultra-thin body devices, where the vertical junction is limited by a geometric constraint. The optimum gate overlap is quite small, or may even be negative, making a process without the need of high-tilt implantation feasible, even for dopant activation with negligible diffusion by flash annealing or laser thermal processing. Dopant activation by solid phase epitaxial regrowth might require high-tilt implants for a positive overlap. The use of such implants, however, is expected to lead to severe gate-poly and gate-oxide degradation. Scaling the 150 nm technology has drastically shrunk the overlap, accomplished by an equally aggressive reduction in thermal budget. For a 65 nm node device, a significant fraction of the overlap originates in the as-implanted dopant profile and the importance of diffusion is diminished. As a consequence small changes in the as-implanted profile are beginning to have a disproportionate impact on device characteristics. Small angular deviations of the incident beam from normal incidence, as seen by the wafer, lead to large changes in on-current. This can be alleviated significantly by a quad implant provided the tilt-angle is sufficiently large, in the order >5 deg.

  6. Multi-angle Imaging SpectroRadiometer

    Science.gov (United States)

    Diner, David J. (Principal Investigator)

    MISR views the sunlit Earth simultaneously at nine widely spaced angles and provides ongoing global coverage with high spatial detail. Its imagery is carefully calibrated to provide accurate measures of the brightness, contrast, and color of reflected sunlight. MISR provides new types of information for scientists studying Earth's climate, such as the regional and global distribution of different types of atmospheric particles and aerosols. The change in reflection at different view angles provides the means to distinguish aerosol types, cloud forms, and land surface cover. Combined with stereoscopic techniques, this enables construction of 3-D cloud models and estimation of the total amount of sunlight reflected by Earth's diverse environments. MISR was built for NASA by the Jet Propulsion Laboratory (JPL) in Pasadena, California. It is part of NASA's first Earth Observing System (EOS) spacecraft, the Terra spacecraft, which was launched into polar orbit from Vandenberg Air Force Base on December 18, 1999. MISR has been continuously providing data since February 24, 2000. [Mission Objectives] The MISR instrument acquires systematic multi-angle measurements for global monitoring of top-of-atmosphere and surface albedos and for measuring the shortwave radiative properties of aerosols, clouds, and surface scenes in order to characterize their impact on the Earth's climate. The Earth's climate is constantly changing -- as a consequence of both natural processes and human activities. Scientists care a great deal about even small changes in Earth's climate, since they can affect our comfort and well-being, and possibly our survival. A few years of below-average rainfall, an unusually cold winter, or a change in emissions from a coal-burning power plant, can influence the quality of life of people, plants, and animals in the region involved. The goal of NASA's Earth Observing System (EOS) is to increase our understanding of the climate changes that are occurring on our

  7. Effects of Angle Variations in Suspension Push-up Exercise.

    Science.gov (United States)

    Gulmez, Irfan

    2017-04-01

    Gulmez, I. Effects of angle variations in suspension push-up exercise. J Strength Cond Res 31(4): 1017-1023, 2017-This study aimed to determine and compare the amount of loads on the TRX Suspension Trainer (TRX) straps and ground reaction forces at 4 different angles during TRX push-ups. Twenty-eight male (mean age, 24.1 ± 2.9 years; height, 179.4 ± 8.0 m; weight, 78.8 ± 9.8 kg) physical education and sports university students participated in this study. The subjects were tested at TRX angles (0, 15, 30, 45°) during the TRX push-ups. Force data were recorded by a force platform and load cells integrated into the TRX straps. The results show that as the TRX angle was reduced, the load applied to the TRX straps increased and simultaneously the load measured by the force platform decreased. This was true for both the elbow joint changing from flexion to extension and vice versa. When the TRX angle was set at 0° and subjects' elbows were at extension during TRX push-up, 50.4% of the subjects' body weight, and when the elbows were at flexion, 75.3% of the body weight was registered by the sensors on the TRX straps. The results of this study can be used in the calculation of the training load and volume (resistance training programming) during TRX push-up exercises at varying angles.

  8. Detection device for inside of space

    International Nuclear Information System (INIS)

    Kojima, Kosuke.

    1996-01-01

    A securing plate is disposed to a support column which can be inserted to a space, and a rotational member on which equipments for detection are loaded is disposed rotatably in the longitudinal direction of the support column at a predetermined distance from the securing plate. Shape memory alloy wires that shrink when current is supplied are stretched circumferentially each at a predetermined distance obliquely relative to the support column between the rotational member and the securing plate. In addition, there are disposed a sensor for detecting the rotational angle of the rotational member, a calculator for determining the deviation of the angle of the rotation based on the difference of the detected rotational angle and a predetermined rotational angle as a reference, a deviation counter for obtaining deviation count signals based on the deviation of the rotational angle, a D-A convertor for converting the deviation count signals to analog signals, a pulse width modulation device for duty ratio control based on the analog signals and output pulse signals, and a power amplifier for amplifying the pulse signals and applying them to the shape memory wires. Since the device is reduced in the size and weight, handling is facilitated, and the rotational angle can be controlled accurately. The device can be used for detection of an end plate in a pressure vessel. (N.H.)

  9. Guide device

    International Nuclear Information System (INIS)

    Brammer, C.M. Jr.

    1977-01-01

    Disclosed is a fuel handling guide tube centering device for use in nuclear reactors during fuel assembly handling operations. The device comprises an outer ring secured to the flange of a nuclear reactor pressure vessel, a rotatable table rotatably coupled to the outer ring, and a plurality of openings through the table. Truncated locating cones are positioned in each of the openings in the table, and the locating cones center the guide tube during fuel handling operations. The openings in the table are located such that each fuel assembly in the nuclear core may be aligned with one of the openings by a suitable rotation of the table. The locating cones thereby provide alignment between the fuel handling mechanism located in the guide tube and the individual fuel assemblies of the cone. The need for a device to provide alignment is especially critical for floating nuclear power plants, where wave motion may exist during fuel handling operations. 5 claims, 4 figures

  10. Dye and pigment-free structural colors and angle-insensitive spectrum filters

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Lingjie Jay; Hollowell, Andrew E.; Wu, Yi-Kuei

    2017-01-17

    Optical spectrum filtering devices displaying minimal angle dependence or angle insensitivity are provided. The filter comprises a localized plasmonic nanoresonator assembly having a metal material layer defining at least one nanogroove and a dielectric material disposed adjacent to the metal material layer. The dielectric material is disposed within the nanogroove(s). The localized plasmonic nanoresonator assembly is configured to funnel and absorb a portion of an electromagnetic spectrum in the at least one nanogroove via localized plasmonic resonance to generate a filtered output having a predetermined range of wavelengths that displays angle insensitivity. Thus, flexible, high efficiency angle independent color filters having very small diffraction limits are provided that are particularly suitable for use as pixels for various display devices or for use in anti-counterfeiting and cryptography applications. The structures can also be used for colored print applications and the elements can be rendered as pigment-like particles.

  11. IMU-Based Joint Angle Measurement for Gait Analysis

    Directory of Open Access Journals (Sweden)

    Thomas Seel

    2014-04-01

    Full Text Available This contribution is concerned with joint angle calculation based on inertial measurement data in the context of human motion analysis. Unlike most robotic devices, the human body lacks even surfaces and right angles. Therefore, we focus on methods that avoid assuming certain orientations in which the sensors are mounted with respect to the body segments. After a review of available methods that may cope with this challenge, we present a set of new methods for: (1 joint axis and position identification; and (2 flexion/extension joint angle measurement. In particular, we propose methods that use only gyroscopes and accelerometers and, therefore, do not rely on a homogeneous magnetic field. We provide results from gait trials of a transfemoral amputee in which we compare the inertial measurement unit (IMU-based methods to an optical 3D motion capture system. Unlike most authors, we place the optical markers on anatomical landmarks instead of attaching them to the IMUs. Root mean square errors of the knee flexion/extension angles are found to be less than 1° on the prosthesis and about 3° on the human leg. For the plantar/dorsiflexion of the ankle, both deviations are about 1°.

  12. The new INRIM rotating encoder angle comparator (REAC)

    International Nuclear Information System (INIS)

    Pisani, Marco; Astrua, Milena

    2017-01-01

    A novel angle comparator has been built and tested at INRIM. The device is based on a double air bearing structure embedding a continuously rotating encoder, which is read by two heads: one fixed to the base of the comparator and a second fixed to the upper moving part of the comparator. The phase measurement between the two heads’ signals is proportional to the relative angle suspended between them (and, therefore, the angle between the base and the upper, movable part of the comparator). The advantage of this solution is to reduce the encoder graduation errors and to cancel the cyclic errors due to the interpolation of the encoder lines. By using only two pairs of reading heads, we have achieved an intrinsic accuracy of  ±0.04″ (rectangular distribution) that can be reduced through self-calibration. The residual cyclic errors have shown to be less than 0.01″ peak-to-peak. The random fluctuations are less than 0.01″ rms on a 100 s time interval. A further advantage of the rotating encoder is the intrinsic knowledge of the absolute position without the need of a zeroing procedure. Construction details of the rotating encoder angle comparator (REAC), characterization tests, and examples of practical use are given. (paper)

  13. Investigations of time resolved x-ray wide-angle scattering and x-ray small-angle scattering at DESY

    International Nuclear Information System (INIS)

    Zachmann, H.G.; Gehrke, R.; Prieske, W.; Riekel, C.

    1985-01-01

    Instrumentation is described for the simultaneous wide-angle and small-angle x-ray scattering. The method was applied to the study of the isothermal crystallization of polyethylene terephthalates. In agreement with the classical theories of crystallization, the data showed that the density difference between the crystals and the non-crystalline regions does not change with time. The mechanisms of melting, recrystallization, and crystal thickening were investigated by small-angle x-ray scattering with stepwise changes and continuous changes of temperature using polyethylene terephthalate

  14. Evaluation of Lumbosacral Angle (LSA and its Impact on Patients with Lumbar Disc Herniation

    Directory of Open Access Journals (Sweden)

    Abdurrahman Aycan

    2016-04-01

    Full Text Available Aim: One of the most common causes of low back pain is lumbar disc herniation (LDH. One of the treatments for patients with LDH is a surgical operation. Changes in the lumbar lordosis angle have a negative impact on patients, clinically. The significance of changes in the lordosis-sacral inclination angle that are associated with muscle spasms and are seen after LDH surgery is known. In this study, we would like to examine the clinical impact on patients due to changes in the lumbosacral angle measured before and after surgical operations in patients with LDH. Material and Method: Between 2005%u20132007, preoperative and postoperative lumbosacral angles of 139 patients operated on for a diagnosis of lumbar disc herniation were measured. Patients were evaluated with the Oswestry Scale, Visual Analogue Scale, Narcotic Score, and Patient Satisfaction Evaluation. Lumbar lordosis angle, sacral inclination angle, and disc height were calculated by direct radiography. Statistical analysis was performed with GraphPad Prisma V.3 software package. Results: In this study, increases of lordosis angles and sacral inclination angles have been observed, postoperatively. It has been shown that these have a positive impact on the clinical course. Discussion: The clinical effects of the biomechanics of angles of patients with LDH are clear. Biomechanical parameters should be considered at preoperative treatment, postoperative treatment, and postoperative controls. The patient%u2019s lordosis angle, neighboring disc structure, and relationship with the sacrum must be carefully evaluated for surgical decision.

  15. Trans-palpebral illumination: an approach for wide-angle fundus photography without the need for pupil dilation

    OpenAIRE

    Toslak, Devrim; Thapa, Damber; Chen, Yanjun; Erol, Muhammet Kazim; Paul Chan, R. V.; Yao, Xincheng

    2016-01-01

    It is technically difficult to construct wide-angle fundus imaging devices due to the complexity of conventional transpupillary illumination and imaging mechanisms. We report here a new method, i.e., trans-palpebral illumination, for wide-angle fundus photography without the need for pupil dilation. By constructing a smartphone-based prototype imaging device, we demonstrated a 152° view in a single-shot image. The unique combination of low-cost smartphone design and automatic illumination opt...

  16. The Q-angle and sport

    DEFF Research Database (Denmark)

    Hahn, Thomas; Foldspang, Anders

    1997-01-01

    Quadriceps muscle contraction tends to straighten the Q angle. We expected that sports comprising a high amount of quadriceps training could be associated with low Q angles. The aim of the present study was to estimate the Q angle in athletes and to investigate its potential associations with par......Quadriceps muscle contraction tends to straighten the Q angle. We expected that sports comprising a high amount of quadriceps training could be associated with low Q angles. The aim of the present study was to estimate the Q angle in athletes and to investigate its potential associations...... with participation in sport. Three hundred and thirty-nine athletes had their Q angle measured. The mean of right-side Q angles was higher than left side, and the mean Q angle was higher in women than in men. The Q angle was positively associated with years of jogging, and negatively with years of soccer, swimming...... and sports participation at all. It is concluded that the use of Q angle measurements is questionable....

  17. Small angle X-ray scattering from hydrating tricalcium silicate

    International Nuclear Information System (INIS)

    Vollet, D.

    1983-01-01

    The small-angle X-ray scattering technique was used to study the structural evolution of hydrated tricalcium silicate at room temperature. The changes in specific area of the associated porosity and the evolution of density fluctuations in the solid hydrated phase were deduced from the scattering data. A correlation of these variations with the hydration mechanism is tried. (Author) [pt

  18. Medical Devices

    NARCIS (Netherlands)

    Verkerke, Gijsbertus Jacob; Mahieu, H.F.; Geertsema, A.A.; Hermann, I.F.; van Horn, J.R.; Hummel, J. Marjan; van Loon, J.P.; Mihaylov, D.; van der Plaats, A.; Schraffordt Koops, H.; Schutte, H.K.; Veth, R.P.H.; de Vries, M.P.; Rakhorst, G.; Shi, Donglu

    2004-01-01

    The development of new medical devices is a very time-consuming and costly process. Besides the time between the initial idea and the time that manufacturing and testing of prototypes takes place, the time needed for the development of production facilities, production of test series, marketing,

  19. Electrochemical device

    Science.gov (United States)

    Grimes, Patrick G.; Einstein, Harry; Bellows, Richard J.

    1988-01-12

    A tunnel protected electrochemical device features channels fluidically communicating between manifold, tunnels and cells. The channels are designed to provide the most efficient use of auxiliary power. The channels have a greater hydraulic pressure drop and electrical resistance than the manifold. This will provide a design with the optimum auxiliary energy requirements.

  20. Assistive Devices

    Science.gov (United States)

    If you have a disability or injury, you may use a number of assistive devices. These are tools, products or types of equipment that help you perform tasks and activities. They may help you move around, see, communicate, eat, or get ...

  1. Detection device

    Science.gov (United States)

    Smith, J.E.

    1981-02-27

    The present invention is directed to a detection device comprising: (1) an entrance chamber; (2) a central chamber; and (3) an exit chamber. The central chamber includes an ionizing gas, anode, and means for connecting the anode with an external power supply and pulse counter.

  2. Wafer scale oblique angle plasma etching

    Science.gov (United States)

    Burckel, David Bruce; Jarecki, Jr., Robert L.; Finnegan, Patrick Sean

    2017-05-23

    Wafer scale oblique angle etching of a semiconductor substrate is performed in a conventional plasma etch chamber by using a fixture that supports a multiple number of separate Faraday cages. Each cage is formed to include an angled grid surface and is positioned such that it will be positioned over a separate one of the die locations on the wafer surface when the fixture is placed over the wafer. The presence of the Faraday cages influences the local electric field surrounding each wafer die, re-shaping the local field to be disposed in alignment with the angled grid surface. The re-shaped plasma causes the reactive ions to follow a linear trajectory through the plasma sheath and angled grid surface, ultimately impinging the wafer surface at an angle. The selected geometry of the Faraday cage angled grid surface thus determines the angle at with the reactive ions will impinge the wafer.

  3. Proximal thoracic aorta dimensions after continuous-flow left ventricular assist device implantation: Longitudinal changes and relation to aortic valve insufficiency.

    Science.gov (United States)

    Fine, Nowell M; Park, Soon J; Stulak, John M; Topilsky, Yan; Daly, Richard C; Joyce, Lyle D; Pereira, Naveen L; Schirger, John A; Edwards, Brooks S; Lin, Grace; Kushwaha, Sudhir S

    2016-04-01

    In this study we examined the impact of continuous-flow left ventricular assist device (CF-LVAD) support on proximal thoracic aorta dimensions. Aortic root and ascending aorta diameter were measured from serial echocardiograms before and after CF-LVAD implantation in patients with ≥6 months of support, and correlated with the development of >mild aortic valve insufficiency (AI). Of 162 patients included, mean age was 58 ± 11 years and 128 (79%) were male. Seventy-nine (63%) were destination therapy patients. Mean aortic root and ascending aorta diameters at baseline, 1 month, 6 months, 12 months and long-term follow-up (mean 2.0 ± 1.4 years) were 3.5 ± 0.4, 3.5 ± 0.3, 3.9 ± 0.3, 3.9 ± 0.2 and 4.0 ± 0.3, and 3.3 ± 0.2, 3.3 ± 0.3, 3.6 ± 0.2, 3.6 ± 0.3 and 3.6 ± 0.3 cm, respectively. Only change in aortic root diameter from 1-month to 6-month follow-up reached statistical significance (p = 0.03). Nine (6%) patients had accelerated proximal thoracic aorta expansion (>0.5 cm/year), occurring predominantly in the first 6 months after implantation. These patients were older and more likely to have hypertension and baseline proximal thoracic aorta dilation. Forty-five (28%) patients developed >mild AI at long-term follow-up, including 7 of 9 (78%) of those with accelerated proximal thoracic aorta expansion. All 7 had aortic valves that remained closed throughout the cardiac cycle, and this, along with duration of CF-LVAD support and increase in aortic root diameter, were significantly associated with developing >mild AI. CF-LVAD patients have small increases in proximal thoracic aorta dimensions that predominantly occur within the first 6 months after implantation and then stabilize. Increasing aortic root diameter was associated with AI development. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  4. Effects of Three Motivationally Targeted Mobile Device Applications on Initial Physical Activity and Sedentary Behavior Change in Midlife and Older Adults: A Randomized Trial.

    Directory of Open Access Journals (Sweden)

    Abby C King

    Full Text Available While there has been an explosion of mobile device applications (apps promoting healthful behaviors, including physical activity and sedentary patterns, surprisingly few have been based explicitly on strategies drawn from behavioral theory and evidence.This study provided an initial 8-week evaluation of three different customized physical activity-sedentary behavior apps drawn from conceptually distinct motivational frames in comparison with a commercially available control app.Ninety-five underactive adults ages 45 years and older with no prior smartphone experience were randomized to use an analytically framed app, a socially framed app, an affectively framed app, or a diet-tracker control app. Daily physical activity and sedentary behavior were measured using the smartphone's built-in accelerometer and daily self-report measures.Mixed-effects models indicated that, over the 8-week period, the social app users showed significantly greater overall increases in weekly accelerometry-derived moderate to vigorous physical activity relative to the other three arms (P values for between-arm differences = .04-.005; Social vs. Control app: d = 1.05, CI = 0.44,1.67; Social vs. Affect app: d = 0.89, CI = 0.27,1.51; Social vs. Analytic app: d = 0.89, CI = 0.27,1.51, while more variable responses were observed among users of the other two motivationally framed apps. Social app users also had significantly lower overall amounts of accelerometry-derived sedentary behavior relative to the other three arms (P values for between-arm differences = .02-.001; Social vs. Control app: d = 1.10,CI = 0.48,1.72; Social vs. Affect app: d = 0.94, CI = 0.32,1.56; Social vs. Analytic app: d = 1.24, CI = 0.59,1.89. Additionally, Social and Affect app users reported lower overall sitting time compared to the other two arms (P values for between-arm differences < .001; Social vs. Control app: d = 1.59,CI = 0.92, 2.25; Social vs. Analytic app: d = 1.89,CI = 1.17, 2.61; Affect

  5. Effects of Three Motivationally Targeted Mobile Device Applications on Initial Physical Activity and Sedentary Behavior Change in Midlife and Older Adults: A Randomized Trial.

    Science.gov (United States)

    King, Abby C; Hekler, Eric B; Grieco, Lauren A; Winter, Sandra J; Sheats, Jylana L; Buman, Matthew P; Banerjee, Banny; Robinson, Thomas N; Cirimele, Jesse

    2016-01-01

    While there has been an explosion of mobile device applications (apps) promoting healthful behaviors, including physical activity and sedentary patterns, surprisingly few have been based explicitly on strategies drawn from behavioral theory and evidence. This study provided an initial 8-week evaluation of three different customized physical activity-sedentary behavior apps drawn from conceptually distinct motivational frames in comparison with a commercially available control app. Ninety-five underactive adults ages 45 years and older with no prior smartphone experience were randomized to use an analytically framed app, a socially framed app, an affectively framed app, or a diet-tracker control app. Daily physical activity and sedentary behavior were measured using the smartphone's built-in accelerometer and daily self-report measures. Mixed-effects models indicated that, over the 8-week period, the social app users showed significantly greater overall increases in weekly accelerometry-derived moderate to vigorous physical activity relative to the other three arms (P values for between-arm differences = .04-.005; Social vs. Control app: d = 1.05, CI = 0.44,1.67; Social vs. Affect app: d = 0.89, CI = 0.27,1.51; Social vs. Analytic app: d = 0.89, CI = 0.27,1.51), while more variable responses were observed among users of the other two motivationally framed apps. Social app users also had significantly lower overall amounts of accelerometry-derived sedentary behavior relative to the other three arms (P values for between-arm differences = .02-.001; Social vs. Control app: d = 1.10,CI = 0.48,1.72; Social vs. Affect app: d = 0.94, CI = 0.32,1.56; Social vs. Analytic app: d = 1.24, CI = 0.59,1.89). Additionally, Social and Affect app users reported lower overall sitting time compared to the other two arms (P values for between-arm differences < .001; Social vs. Control app: d = 1.59,CI = 0.92, 2.25; Social vs. Analytic app: d = 1.89,CI = 1.17, 2.61; Affect vs. Control

  6. [Experimental hypertony caused by obstruction of the anterior chamber angle ab interno (author's transl)].

    Science.gov (United States)

    Maguritsas, N; Vikas, C; Theodossiadis, G; Vergados, I; Velissaropoulos, P

    1976-07-01

    In 30 rabbits, separated into 3 groups (A, B and C), the entire area (A), three quarters (B) half of the anterior chamber angle (C) was experimentally obstructed by means of a homologous scleral graft. In groups A and B a statistically significant change of the intraocular pressure and of the cornea diameter was shown as compared with the control eye and group C. This change is due to the obstructed area of the angle. The increased intraocular pressure lasted for some months. The graft was well tolerated by the tissue of the angle and the obstruction of the angle was total, as was confirmed by means of the histological preparations.

  7. Cooling device in thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Tsutomu.

    1988-01-01

    Purpose: To prevent loss of cooling effect over the entire torus structure directly after accidental toubles in a cooling device of a thermonuclear device. Constitution: Coolant recycling means of a cooling device comprises two systems, which are alternately connected with in-flow pipeways and exit pipeways of adjacent modules. The modules are cooled by way of the in-flow pipeways and the exist pipeways connected to the respective modules by means of the coolant recycling means corresponding to the respective modules. So long as one of the coolant recycling means is kept operative, since every one other modules of the torus structure is still kept cooled, the heat generated from the module put therebetween, for which the coolant recycling is interrupted, is removed by means of heat conduction or radiation from the module for which the cooling is kept continued. No back-up emergency cooling system is required and it can provide high economic reliability. (Kamimura, M.)

  8. Evaluation of blotchy pigments in the anterior chamber angle as a sign of angle closure

    Directory of Open Access Journals (Sweden)

    Harsha L Rao

    2012-01-01

    Full Text Available Background: Blotchy pigments in the anterior chamber (AC angle are considered diagnostic of primary angle closure (PAC. But there are no reports either on the prevalence of blotchy pigments in AC angles or the validity of this sign. Aims: To determine the prevalence of blotchy pigments in AC angles and to evaluate their relationship with glaucomatous optic neuropathy (GON in eyes with occludable angles. Setting and Design: Cross-sectional, comparative study. Materials and Methods: Gonioscopy was performed in 1001 eyes of 526 subjects (245 eyes of 148 consecutive, occludable angle subjects and 756 eyes of 378 non-consecutive, open angle subjects, above 35 years of age. Quadrant-wise location of blotchy pigments was documented. Statistical Analysis: Odds of blotchy pigments in occludable angles against that in open angles were evaluated. Relationship of GON with blotchy pigments in occludable angle eyes was evaluated using a multivariate model. Results: Prevalence of blotchy pigments in occludable angles was 28.6% (95% CI, 22.9-34.3 and in open angles was 4.7% (95% CI, 3.2-6.3. Blotchy pigments were more frequently seen in inferior (16% and superior quadrants (15% of occludable angles, and inferior quadrant of open angles (4%. Odds of superior quadrant blotchy pigments in occludable angles were 33 times that in open angles. GON was seen in 107 occludable angle eyes. Blotchy pigments were not significantly associated with GON (odds ratio = 0.5; P = 0.1. Conclusions: Blotchy pigments were seen in 28.6% of occludable angle eyes and 4.7% of open angles eyes. Presence of blotchy pigments in the superior quadrant is more common in occludable angles. Presence of GON in occludable angle eyes was not associated with blotchy pigments.

  9. Evaluation of blotchy pigments in the anterior chamber angle as a sign of angle closure

    Science.gov (United States)

    Rao, Harsha L; Mungale, Sachin C; Kumbar, Tukaram; Parikh, Rajul S; Garudadri, Chandra S

    2012-01-01

    Background: Blotchy pigments in the anterior chamber (AC) angle are considered diagnostic of primary angle closure (PAC). But there are no reports either on the prevalence of blotchy pigments in AC angles or the validity of this sign. Aims: To determine the prevalence of blotchy pigments in AC angles and to evaluate their relationship with glaucomatous optic neuropathy (GON) in eyes with occludable angles. Setting and Design: Cross-sectional, comparative study. Materials and Methods: Gonioscopy was performed in 1001 eyes of 526 subjects (245 eyes of 148 consecutive, occludable angle subjects and 756 eyes of 378 non-consecutive, open angle subjects), above 35 years of age. Quadrant-wise location of blotchy pigments was documented. Statistical Analysis: Odds of blotchy pigments in occludable angles against that in open angles were evaluated. Relationship of GON with blotchy pigments in occludable angle eyes was evaluated using a multivariate model. Results: Prevalence of blotchy pigments in occludable angles was 28.6% (95% CI, 22.9-34.3) and in open angles was 4.7% (95% CI, 3.2-6.3). Blotchy pigments were more frequently seen in inferior (16%) and superior quadrants (15%) of occludable angles, and inferior quadrant of open angles (4%). Odds of superior quadrant blotchy pigments in occludable angles were 33 times that in open angles. GON was seen in 107 occludable angle eyes. Blotchy pigments were not significantly associated with GON (odds ratio = 0.5; P = 0.1). Conclusions: Blotchy pigments were seen in 28.6% of occludable angle eyes and 4.7% of open angles eyes. Presence of blotchy pigments in the superior quadrant is more common in occludable angles. Presence of GON in occludable angle eyes was not associated with blotchy pigments. PMID:23202393

  10. Electronic control devices

    International Nuclear Information System (INIS)

    Hartill, D.L.

    1981-01-01

    The subject of these lectures is the translation of information from particle detectors to computers. Large solid angle general purpose detectors at the intersection regions of high energy e+e- storage rings and pp and pp storage rings are discussed. Three choices for data acquisition are reviewed: use CAMAC (Computer Aided Measurement and Control), start from scratch and design a system, or wait for the final version of the proposed FASTBUS to be developed. The do-it-yourself procedure includes designs of drift chamber discriminator, time to amplitude converter, and data card block diagram. Trigger systems, the fast decision making systems judging an event interesting enough for a read-out cycle to be initiated, are discussed. Finally, a FASTBUS system layout, with its goals of minimum bus speed, general system topologies, and support multiple smart devices is given

  11. Equipment abnormality monitoring device

    International Nuclear Information System (INIS)

    Ando, Yasumasa

    1991-01-01

    When an operator hears sounds in a plantsite, the operator compares normal sounds of equipment which he previously heard and remembered with sounds he actually hears, to judge if they are normal or abnormal. According to the method, there is a worry that abnormal conditions can not be appropriately judged in a case where the number of objective equipments is increased and in a case that the sounds are changed gradually slightly. Then, the device of the present invention comprises a plurality of monitors for monitoring the operation sound of equipments, a recording/reproducing device for recording and reproducing the signals, a selection device for selecting the reproducing signals among the recorded signals, an acoustic device for converting the signals to sounds, a switching device for switching the signals to be transmitted to the acoustic device between to signals of the monitor and the recording/reproducing signals. The abnormality of the equipments can be determined easily by comparing the sounds representing the operation conditions of equipments for controlling the plant operation and the sounds recorded in their normal conditions. (N.H.)

  12. Electronic security device

    Science.gov (United States)

    Eschbach, Eugene A.; LeBlanc, Edward J.; Griffin, Jeffrey W.

    1992-01-01

    The present invention relates to a security device having a control box (12) containing an electronic system (50) and a communications loop (14) over which the system transmits a signal. The device is constructed so that the communications loop can extend from the control box across the boundary of a portal such as a door into a sealed enclosure into which access is restricted whereby the loop must be damaged or moved in order for an entry to be made into the enclosure. The device is adapted for detecting unauthorized entries into such enclosures such as rooms or containers and for recording the time at which such entries occur for later reference. Additionally, the device detects attempts to tamper or interfere with the operation of the device itself and records the time at which such events take place. In the preferred embodiment, the security device includes a microprocessor-based electronic system (50) and a detection module (72) capable of registering changes in the voltage and phase of the signal transmitted over the loop.

  13. Electronic security device

    International Nuclear Information System (INIS)

    Eschbach, E.A.; LeBlanc, E.J.; Griffin, J.W.

    1992-01-01

    The present invention relates to a security device having a control box containing an electronic system and a communications loop over which the system transmits a signal. The device is constructed so that the communications loop can extend from the control box across the boundary of a portal such as a door into a sealed enclosure into which access is restricted whereby the loop must be damaged or moved in order for an entry to be made into the enclosure. The device is adapted for detecting unauthorized entries into such enclosures such as rooms or containers and for recording the time at which such entries occur for later reference. Additionally, the device detects attempts to tamper or interfere with the operation of the device itself and records the time at which such events take place. In the preferred embodiment, the security device includes a microprocessor-based electronic system and a detection module capable of registering changes in the voltage and phase of the signal transmitted over the loop. 11 figs

  14. New Design of Blade Untwisting Device of Cyclone Unit

    Directory of Open Access Journals (Sweden)

    D. I. Misiulia

    2010-01-01

    Full Text Available The paper presents a new design of a blade untwisting device where blades are considered as a main element of the device. A profile of the blades corresponds to a circular arch. An inlet angle of  the blades is determined by stream aerodynamics in an exhaust pipe, and an exit angle is determined by rectilinear gas motion. Optimum geometrical parameters of the untwisting device have been determined and its application allows to reduce a pressure drop in the ЦН-15 cyclones by 28–30 % while screw-blade untwisting device recovers only 19–20 % of energy.

  15. Capillary surfaces in a wedge: Differing contact angles

    Science.gov (United States)

    Concus, Paul; Finn, Robert

    1994-01-01

    The possible zero-gravity equilibrium configurations of capillary surfaces u(x, y) in cylindrical containers whose sections are (wedge) domains with corners are investigated mathematically, for the case in which the contact angles on the two sides of the wedge may differ. In such a situation the behavior can depart in significant qualitative ways from that for which the contact angles on the two sides are the same. Conditions are described under which such qualitative changes must occur. Numerically computed surfaces are depicted to indicate the behavior.

  16. Method and apparatus for controlling pitch and flap angles of a wind turbine

    Science.gov (United States)

    Deering, Kenneth J [Seattle, WA; Wohlwend, Keith P [Issaquah, WA

    2009-05-12

    A wind turbine with improved response to wind conditions is provided. Blade flap angle motion is accompanied by a change in pitch angle by an amount defining a pitch/flap coupling ratio. The coupling ratio is non-constant as a function of a flap angle and is preferably a substantially continuous, non-linear function of flap angle. The non-constant coupling ratio can be provided by mechanical systems such as a series of linkages or by configuring electronic or other control systems and/or angle sensors. A link with a movable proximal end advantageously is part of the mechanical system. The system can provide relatively large coupling ratios and relatively large rates of coupling ratio changes especially for near-feather pitches and low flap angles.

  17. The paediatric Bohler's angle and crucial angle of Gissane: a case series

    Directory of Open Access Journals (Sweden)

    Crawford Haemish A

    2011-01-01

    Full Text Available Abstract Background Bohler's angle and the crucial angle of Gissane can be used to assess calcaneal fractures. While the normal adult values of these angles are widely known, the normal paediatric values have not yet been established. Our aim is to investigate Bohler's angle and the crucial angle of Gissane in a paediatric population and establish normal paediatric reference values. Method We measured Bohler's angle and the crucial angle of Gissane using normal plain ankle radiographs of 763 patients from birth to 14 years of age completed over a five year period from July 2003 to June 2008. Results In our paediatric study group, the mean Bohler's angle was 35.2 degrees and the mean crucial angle of Gissane was 111.3 degrees. In an adult comparison group, the mean Bohler's angle was 39.2 degrees and the mean crucial angle of Gissane was 113.8 degrees. The differences in Bohler's angle and the crucial angle of Gissane between these two groups were statistically significant. Conclusion We have presented the normal values of Bohler's angle and the crucial angle of Gissane in a paediatric population. These values may provide a useful comparison to assist with the management of the paediatric calcaneal fracture.

  18. Thermonuclear device

    International Nuclear Information System (INIS)

    Tezuka, Masaru.

    1993-01-01

    Protrusions and recesses are formed to a vacuum vessel and toroidal magnetic coils, and they are engaged. Since the vacuum vessel is generally supported firmly by a rack or the like by support legs, the toroidal magnetic field coils can be certainly supported against tumbling force. Then, there can be attained strong supports for the toroidal magnetic field coils, in addition to support by wedges on the side of inboard and support by share panels on the side of outboard, capable of withstanding great electromagnetic forces which may occur in large-scaled next-generation devices. That is, toroidal magnetic field coils excellent from a view point of deformation and stress can be obtained, to provide a thermonuclear device of higher reliability. (N.H.)

  19. Thermonuclear device

    International Nuclear Information System (INIS)

    Oosaki, Osamu; Masuda, Kenju.

    1980-01-01

    Purpose: To provide excellent electric properties and high reliability in a thermonuclear device by improving a current collecting board connected to a coil device. Constitution: A current collecting board element perforated with an opening for enserting a connecting terminal is sized to be inserted into a plating tank, and is surface treated in the plating tank. Only the current collecting board element preferably surface treated is picked up. A plurality of such current collecting board elements are connected and welded to form a large current collecting board. In this manner, the current collecting board having several m 2 to several ten order m 2 in area can be obtained as preferably surface treated at the connecting terminal hole. The current collecting board element can be determined in shape with the existing facility without increasing the size of a surface treating tank. (Kamimura, M.)

  20. Thermonuclear device

    International Nuclear Information System (INIS)

    Yagi, Yasuomi; Takahashi, Ken; Hashimoto, Hiroshi.

    1984-01-01

    Purpose: To improve the plasma confining performances by bringing the irregular magnetic fields nearly to zero and decreasing the absolute value of the irregular magnetic fields at every positions. Constitution: The winding direction of a plurality of coil elements, for instance, double pan cake coils of toroidal coils in a torus type or mirror type thermonuclear device are reversed to each other in their laminating direction, whereby the irregular magnetic fields due to the coil-stepped portions in each toroidal coils are brought nearly to zero. This enables to bring the average irregular magnetic fields as a whole in the thermonuclear device nearly to zero, as well as, decrease the absolute value of the irregular magnetic fields in each positions. Thus, the plasma confining performances can be improved. (Moriyama, K.)

  1. Plasma facing device of thermonuclear device

    International Nuclear Information System (INIS)

    Sumita, Hideo; Ioki, Kimihiro.

    1993-01-01

    The present invention improves integrity of thermal structures of a plasma facing device. That is, in the plasma facing device, an armour block portion from a metal cooling pipe to a carbon material comprises a mixed material of the metal as the constituent material of the cooling pipe and ceramics. Then, the mixing ratio of the composition is changed continuously or stepwise to suppress peakings of remaining stresses upon production and thermal stresses upon exertion of thermal loads. Accordingly, thermal integrity of the structural materials can further be improved. In this case, a satisfactory characteristic can be obtained also by using ceramics instead of carbon for the mixed material, and the characteristic such as heat expansion coefficient is similar to that of the armour tile. (I.S.)

  2. Effect of tungsten on the phase-change properties of Ge{sub 8}Sb{sub 2}Te{sub 11} Thin Films for the Phase-change device

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheol-Jin; Kong, Heon; Lee, Hyun-Yong; Yeo, Jong-Bin [Chonnam National University, Gwangju (Korea, Republic of)

    2017-07-15

    In this study, the electrical, optical, and structural properties of tungsten (W)-doped Ge{sub 8}Sb{sub 2}Te{sub 11} thin films were investigated. Previously, GeSbTe alloys were doped with various materials in an attempt to improve the thermal stability. Ge{sub 8}Sb{sub 2}Te{sub 11} and W-doped Ge{sub 8}Sb{sub 2}Te{sub 11} films with a thickness of 200 nm were fabricated by using an RF magnetron reactive co-sputtering system at room temperature on Si (p-type, 100) and glass substrate. The fabricated thin films were annealed in a furnace in the ∼ 0 - 400 ℃ temperature range. The optical properties were analyzed using a UV-Vis-IR spectrophotometer, and by using Beer’s Law equation, the optical-energy band gap (E{sub op}), slope B{sup 1/2}, and slope 1/F were calculated. For the crystalline materials, an increase in the slope B{sup 1/2} and 1/F was observed, exhibiting a good effect on the thermal stability in the amorphous state after the phase change. The structural properties were analyzed by X-ray diffraction, and the result showed that the W-doped Ge{sub 8}Sb{sub 2}Te{sub 11} had a face-centered-cubic (fcc) crystalline structure increased crystallization temperature (T{sub c}). An increase in the T{sub c} increased the thermal stability in the amorphous state. The electrical properties were analyzed using a 4-point probe, exhibiting an increase in the sheet resistance (R{sub s}) in the amorphous and the crystalline states indicating a reduced programming current in the memory device.

  3. Nanoscale memory devices

    International Nuclear Information System (INIS)

    Chung, Andy; Deen, Jamal; Lee, Jeong-Soo; Meyyappan, M

    2010-01-01

    This article reviews the current status and future prospects for the use of nanomaterials and devices in memory technology. First, the status and continuing scaling trends of the flash memory are discussed. Then, a detailed discussion on technologies trying to replace flash in the near-term is provided. This includes phase change random access memory, Fe random access memory and magnetic random access memory. The long-term nanotechnology prospects for memory devices include carbon-nanotube-based memory, molecular electronics and memristors based on resistive materials such as TiO 2 . (topical review)

  4. "Distinvar" device

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    The alignment of one of the accelerator magnets being checked by the AR Division survey group. A "distinvar" device, invented by the group, using calibrated invar wires stretched between the fixed survey pillar (on the left) and a fixed point on the magnet. In two days it is thus possible to measure the alignment of the 100 magnets with an accuracy better than 1/10.

  5. Latching device

    Science.gov (United States)

    Ulrich, G. W. (Inventor)

    1975-01-01

    A latching device is suited for use in establishing a substantially motionless connection between a stationary receiver and a movable latching mechanism. The latching mechanism includes a pivotally supported restraining hook continuously urged into a capturing relationship with the receiver, characterized by a spring-biased pawl having a plurality of aligned teeth. The teeth are seated in the surface of the throat of the hook and positionable into restraining engagement with a rigid restraining shoulder projected from the receiver.

  6. Standing phase angle reduction for power system restoration

    Energy Technology Data Exchange (ETDEWEB)

    Hazarika, D. [Assam Engineering College (India). Electrical Engineering Dept.; Sinha, A.K. [IIT Khargpur (India). Electrical Engineering Dept.

    1998-01-01

    The paper describes a methodology for the reduction of standing phase angle (SPA) difference between two buses of a power system, which is essential before interconnecting a line between two buses. This problem is encountered normally during restoration operations of a power system. For this purpose, the standing phase angle difference between two specific buses is represented in terms of sensitivity factors associated with the change in real power injections at the buses. To arrive at the desired standing phase angle difference between two buses, the modified contribution at generation/load buses have been evaluated based on 'higher the sensitivity higher the participation' logic. This methodology acts as a direct help to reduce excessive SPA difference between two buses to an acceptable limit, which otherwise requires regulation of various generation levels on a trial and error basis. (author)

  7. Effect of inlet cone pipe angle in catalytic converter

    Science.gov (United States)

    Amira Zainal, Nurul; Farhain Azmi, Ezzatul; Arifin Samad, Mohd

    2018-03-01

    The catalytic converter shows significant consequence to improve the performance of the vehicle start from it launched into production. Nowadays, the geometric design of the catalytic converter has become critical to avoid the behavior of backpressure in the exhaust system. The backpressure essentially reduced the performance of vehicles and increased the fuel consumption gradually. Consequently, this study aims to design various models of catalytic converter and optimize the volume of fluid flow inside the catalytic converter by changing the inlet cone pipe angles. Three different geometry angles of the inlet cone pipe of the catalytic converter were assessed. The model is simulated in Solidworks software to determine the optimum geometric design of the catalytic converter. The result showed that by decreasing the divergence angle of inlet cone pipe will upsurge the performance of the catalytic converter.

  8. Lifting devices in nuclear facilities

    International Nuclear Information System (INIS)

    The rule is valid for lifts, cranes, winches, rail travel trolleys, load lifting devices and fuel element changing devices for light-water reactors, insofar as these are used in plants to produce or to fission nuclear fuels or to process irradiated nuclear fuels or in the storage or other use of nuclear fuels. (LH) [de

  9. A scoping review on smart mobile devices and physical strain.

    Science.gov (United States)

    Tegtmeier, Patricia

    2018-01-01

    Smart mobile devices gain increasing importance at work. Integrating these smart mobile devices into the workplace creates new opportunities and challenges for occupational health and safety. Therefore the aim of the following scoping review was to identify ergonomic challenges with the use of smart mobile devices at work with respect to physical problems. A review of 36 papers based on literature including January 2016 was conducted. Biomechanical measures in the reviewed studies demonstrated i.e., head flexion angles exceeding 20° in 20 out of 26 different conditions described. Furthermore, laterally deviated wrists were frequently noted and thumb and finger flexor muscle activities generally greater than 5% MVC were reported. The reviewed literature indicated an elevated biomechanical risk, especially for the neck, the wrists and thumb. This was due to poor posture, ongoing and intermitted muscle tension, and/or repetitive movements. Papers addressing specific risks for smartphone and tablet use in different work environments are scarce. As the technology, as well as the use of smart mobile devices is rapidly changing, further research, especially for prolonged periods in the workplace is needed.

  10. Contact angle of a nanodrop on a nanorough solid surface.

    Science.gov (United States)

    Berim, Gersh O; Ruckenstein, Eli

    2015-02-21

    The contact angle of a cylindrical nanodrop on a nanorough solid surface is calculated, for both hydrophobic and hydrophilic surfaces, using the density functional theory. The emphasis of the paper is on the dependence of the contact angle on roughness. The roughness is modeled by rectangular pillars of infinite length located on the smooth surface of a substrate, with fluid-pillar interactions different in strength from the fluid-substrate ones. It is shown that for hydrophobic substrates the trend of the contact angle to increase with increasing roughness, which was noted in all previous studies, is not universally valid, but depends on the fluid-pillar interactions, pillar height, interpillar distance, as well as on the size of the drop. For hydrophilic substrate, an unusual kink-like dependence of the contact angle on the nanodrop size is found which is caused by the change in the location of the leading edges of the nanodrop on the surface. It is also shown that the Wenzel and Cassie-Baxter equations can not explain all the peculiarities of the contact angle of a nanodrop on a nanorough surface.

  11. Repulsion-based model for contact angle saturation in electrowetting.

    Science.gov (United States)

    Ali, Hassan Abdelmoumen Abdellah; Mohamed, Hany Ahmed; Abdelgawad, Mohamed

    2015-01-01

    We introduce a new model for contact angle saturation phenomenon in electrowetting on dielectric systems. This new model attributes contact angle saturation to repulsion between trapped charges on the cap and base surfaces of the droplet in the vicinity of the three-phase contact line, which prevents these surfaces from converging during contact angle reduction. This repulsion-based saturation is similar to repulsion between charges accumulated on the surfaces of conducting droplets which causes the well known Coulombic fission and Taylor cone formation phenomena. In our model, both the droplet and dielectric coating were treated as lossy dielectric media (i.e., having finite electrical conductivities and permittivities) contrary to the more common assumption of a perfectly conducting droplet and perfectly insulating dielectric. We used theoretical analysis and numerical simulations to find actual charge distribution on droplet surface, calculate repulsion energy, and minimize energy of the total system as a function of droplet contact angle. Resulting saturation curves were in good agreement with previously reported experimental results. We used this proposed model to predict effect of changing liquid properties, such as electrical conductivity, and system parameters, such as thickness of the dielectric layer, on the saturation angle, which also matched experimental results.

  12. Numerical study of hub taper angle on podded propeller performance

    International Nuclear Information System (INIS)

    Islam, M.F.; Veitch, B.; Bose, N.; Liu, P.

    2005-01-01

    Presently, the majority of podded propulsion systems are of the pulling type, because this type provides better hydrodynamic efficiency than the pushing type. There are several possible explanations for the better overall performance of a puller type podded propulsor. One is related to the difference in hub shape. Puller and pusher propellers have opposite hub taper angles, hence different hub and blade root shape. These differences cause changes in the flow condition and possibly influence the overall performance. The current study focuses on the variation in performance of pusher and puller propellers with the same blade sections, but different hub taper angles. A hyperboloidal low order source doublet steady/unsteady time domain panel method code was modified and used to evaluate effects of hub taper angle on the open water propulsive performance of some fixed pitch screw propellers used in podded propulsion systems. The modified code was first validated against measurements of two model propellers in terms of average propulsive performance and good agreement was found. Major findings include significant effects of hub taper angle on propulsive performance of tapered hub propellers and noticeable effects of hub taper angle on sectional pressure distributions of tapered hub propeller blades. (author)

  13. A thermodynamic model of contact angle hysteresis.

    Science.gov (United States)

    Makkonen, Lasse

    2017-08-14

    When a three-phase contact line moves along a solid surface, the contact angle no longer corresponds to the static equilibrium angle but is larger when the liquid is advancing and smaller when the liquid is receding. The difference between the advancing and receding contact angles, i.e., the contact angle hysteresis, is of paramount importance in wetting and capillarity. For example, it determines the magnitude of the external force that is required to make a drop slide on a solid surface. Until now, fundamental origin of the contact angle hysteresis has been controversial. Here, this origin is revealed and a quantitative theory is derived. The theory is corroborated by the available experimental data for a large number of solid-liquid combinations. The theory is applied in modelling the contact angle hysteresis on a textured surface, and these results are also in quantitative agreement with the experimental data.

  14. Large - scale Rectangular Ruler Automated Verification Device

    Science.gov (United States)

    Chen, Hao; Chang, Luping; Xing, Minjian; Xie, Xie

    2018-03-01

    This paper introduces a large-scale rectangular ruler automated verification device, which consists of photoelectric autocollimator and self-designed mechanical drive car and data automatic acquisition system. The design of mechanical structure part of the device refer to optical axis design, drive part, fixture device and wheel design. The design of control system of the device refer to hardware design and software design, and the hardware mainly uses singlechip system, and the software design is the process of the photoelectric autocollimator and the automatic data acquisition process. This devices can automated achieve vertical measurement data. The reliability of the device is verified by experimental comparison. The conclusion meets the requirement of the right angle test procedure.

  15. Approach to the determination of the contact angle in hydrophobic samples with simultaneous correction of the effect of the roughness

    Science.gov (United States)

    Domínguez, Noemí; Castilla, Pau; Linzoain, María Eugenia; Durand, Géraldine; García, Cristina; Arasa, Josep

    2018-04-01

    This work presents the validation study of a method developed to measure contact angles with a confocal device in a set of hydrophobic samples. The use of this device allows the evaluation of the roughness of the surface and the determination of the contact angle in the same area of the sample. Furthermore, a theoretical evaluation of the impact of the roughness of a nonsmooth surface in the calculation of the contact angle when it is not taken into account according to Wenzel's model is also presented.

  16. Ultrasonic viewing device

    International Nuclear Information System (INIS)

    Ito, Juro.

    1979-01-01

    Purpose: To improve the safety of reactor operation by enabling to detect the states and positions of fuel assemblies over a wide range with a set of ultrasonic viewing device comprising a rotatable ultrasonic transmitter-receiver and a reflector mounted with an adjustable angle. Constitution: A driving portion for a ultrasonic viewing device is provided to a rotary plug closing the opening of a reactor vessel and a guide pipe suspending below the coolant level is provided to the driving portion. An ultrasonic transmitter-receiver is provided at the end of the holder tube in the guide pipe. A reflector is provided at the upper position of the reactor core so as to correspond to the ultrasonic transmitter-receiver. The ultrasonic transmitter-receiver, positioned by the driving portion, performs horizontal movement for scanning the entire surface of the top of the reactor core, as well as vertical movement covering the gap between the upper mechanism on the reactor and the reactor core, whereby the confirmation for the separation of the control rod and the detection for the states of the reactor core can be conducted by the reflection waves from the reflector. (Moriyama, K.)

  17. Numerical simulation of the effects of variation of angle of attack and sweep angle on vortex breakdown over delta wings

    Science.gov (United States)

    Ekaterinaris, J. A.; Schiff, Lewis B.

    1990-01-01

    In the present investigation of the vortical flowfield structure over delta wings at high angles of attack, three-dimensional Navier-Stokes numerical simulations were conducted to predict the complex leeward flowfield characteristics; these encompass leading-edge separation, secondary separation, and vortex breakdown. Attention is given to the effect on solution accuracy of circumferential grid-resolution variations in the vicinity of the wing leading edge, and well as to the effect of turbulence modeling on the solutions. When a critical angle-of-attack was reached, bubble-type vortex breakdown was found. With further angle-of-attack increase, a change from bubble-type to spiral-type vortex breakdown was predicted by the numerical solution.

  18. Behavior of Tilted Angle Shear Connectors

    Science.gov (United States)

    Khorramian, Koosha; Maleki, Shervin; Shariati, Mahdi; Ramli Sulong, N. H.

    2015-01-01

    According to recent researches, angle shear connectors are appropriate to transfer longitudinal shear forces across the steel-concrete interface. Angle steel profile has been used in different positions as L-shaped or C-shaped shear connectors. The application of angle shear connectors in tilted positions is of interest in this study. This study investigates the behaviour of tilted-shaped angle shear connectors under monotonic loading using experimental push out tests. Eight push-out specimens are tested to investigate the effects of different angle parameters on the ultimate load capacity of connectors. Two different tilted angles of 112.5 and 135 degrees between the angle leg and steel beam are considered. In addition, angle sizes and lengths are varied. Two different failure modes were observed consisting of concrete crushing-splitting and connector fracture. By increasing the size of connector, the maximum load increased for most cases. In general, the 135 degrees tilted angle shear connectors have a higher strength and stiffness than the 112.5 degrees type. PMID:26642193

  19. Behavior of Tilted Angle Shear Connectors.

    Directory of Open Access Journals (Sweden)

    Koosha Khorramian

    Full Text Available According to recent researches, angle shear connectors are appropriate to transfer longitudinal shear forces across the steel-concrete interface. Angle steel profile has been used in different positions as L-shaped or C-shaped shear connectors. The application of angle shear connectors in tilted positions is of interest in this study. This study investigates the behaviour of tilted-shaped angle shear connectors under monotonic loading using experimental push out tests. Eight push-out specimens are tested to investigate the effects of different angle parameters on the ultimate load capacity of connectors. Two different tilted angles of 112.5 and 135 degrees between the angle leg and steel beam are considered. In addition, angle sizes and lengths are varied. Two different failure modes were observed consisting of concrete crushing-splitting and connector fracture. By increasing the size of connector, the maximum load increased for most cases. In general, the 135 degrees tilted angle shear connectors have a higher strength and stiffness than the 112.5 degrees type.

  20. The qualitative criterion of transient angle stability

    DEFF Research Database (Denmark)

    Lyu, R.; Xue, Y.; Xue, F.

    2015-01-01

    In almost all the literatures, the qualitative assessment of transient angle stability extracts the angle information of generators based on the swing curve. As the angle (or angle difference) of concern and the threshold value rely strongly on the engineering experience, the validity and robust...... of these criterions are weak. Based on the stability mechanism from the extended equal area criterion (EEAC) theory and combining with abundant simulations of real system, this paper analyzes the criterions in most literatures and finds that the results could be too conservative or too optimistic. It is concluded...

  1. A probe for Eddy current inspection devices

    International Nuclear Information System (INIS)

    1974-01-01

    The invention relates to a surface probe for Eddy current inspection devices. According to the invention, said probe comprises two magnetic core windings, with their axes in parallel relationship and at right angles to the surface of the part to be inspected. This can be applied to the nondestructive inspection of reactor components [fr

  2. Current sheath curvature correlation with the neon soft x-ray emission from plasma focus device

    International Nuclear Information System (INIS)

    Zhang, T; Lin, X; Chandra, K A; Tan, T L; Springham, S V; Patran, A; Lee, P; Lee, S; Rawat, R S

    2005-01-01

    The insulator sleeve length is one of the major parameters that can severely affect the neon soft x-ray yield from a plasma focus. The effect of the insulation sleeve length on various characteristic timings of plasma focus discharges and hence the soft x-ray emission characteristics has been investigated using a resistive divider. The pinhole images and laser shadowgraphy are used to explain the observed variation in the average soft x-ray yield (measured using a diode x-ray spectrometer) with variation of the insulator sleeve length. We have found that for a neon filled plasma focus device the change in insulator sleeve length changes the current sheath curvature angle and thus the length of the focused plasma column. The optimized current sheath curvature angle is found to be between 39 0 and 41 0 , at the specific axial position of 6.2-9.3 cm from the cathode support plate, for our 3.3 kJ plasma focus device. A strong dependence of the neon soft x-ray yield on the current sheath curvature angle has thus been reported

  3. Evaluation of anterior chamber angle under dark and light conditions in angle closure glaucoma: An anterior segment OCT study.

    Science.gov (United States)

    Masoodi, Habibeh; Jafarzadehpur, Ebrahim; Esmaeili, Alireza; Abolbashari, Fereshteh; Ahmadi Hosseini, Seyed Mahdi

    2014-08-01

    To evaluate changes of nasal and temporal anterior chamber angle (ACA) in subjects with angle closure glaucoma using Spectralis AS-OCT (SAS-OCT) under dark and light conditions. Based on dark-room gonioscopy, 24 subjects with open angles and 86 with narrow angles participated in this study. The nasal and temporal angle opening distance at 500 μm anterior to the scleral spur (AOD500), nasal and temporal ACA were measured using SAS-OCT in light and dark conditions. In 2 groups, ACA and AOD500 in nasal and temporal quadrants were significantly greater in light compared to dark (all with p=0.000). The AOD500 and ACA were significantly higher in nasal than temporal in measured conditions for 2 groups except the ACA and AOD500 of normal group measured in light. The difference between nasal and temporal in dark (29.07 ± 65.71 μm for AOD500 and 5.7 ± 4.07° for ACA) was greater than light (24.86 ± 79.85 μm for AOD500 and 2.09 ± 7.21° for ACA) condition. But the difference was only significant for ACA (p=0.000). The correlation analysis showed a negative correlation between AOD500 and pupil diameter in temporal and nasal quadrants (both with p=0.000). While temporal AOD500 difference correlated with spherical equivalent, temporal and asal gonioscopy, nasal AOD correlated with IOP, temporal and nasal gonioscopy. Clinically important changes in ACA structure could be detected with SAS-OCT in nasal and temporal quadrants under different illumination intensity. The results could help in improvement of examination condition for better and more accurate assessment of individuals with angle closure glaucoma. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  4. Damping device

    International Nuclear Information System (INIS)

    Banks, E.L. Jr.; Dowell, T.P.

    1976-01-01

    The description is given of a damper which includes a pair of telescopic components interconnected by relative linear movement one in relation to the other, by a screw and ball nut device, with a braking surface on one of the components, a brake engaging the braking surface, an inertia mass entrained by the other components, non-deformable and distinct brake actuating gear, independently mobile in relation to the other braking system and fixed and controlled by the inertia mass, positively to engage the braking surface. This damper is for retaining the parts of a nuclear power station so that can withstand earthquakes [fr

  5. Thermonuclear device

    International Nuclear Information System (INIS)

    Inoue, Toyokazu; Murata, Toru.

    1983-01-01

    Purpose: To shield superconducting coils for use in the generation of magnetic field against neutron irradiation thereby preventing tritium contamination. Constitution: The thermonuclear device comprises, in its inside, a vacuum container for containing plasmas, superconducting coils disposed to the outside of the vacuum container and neutron absorbers disposed between the super-conducting coils and the vacuum container. since neutrons issued from the plasma are absorbed by neutron absorbers and not irradiated to the superconducting coils, generation of tritium due to the reaction between 3 He in the liquid helium as the coolants for the super-conducting coils and the neutrons is prevented. (Aizawa, K.)

  6. Strainer device

    International Nuclear Information System (INIS)

    Mokuya, Kenji.

    1975-01-01

    Object: To provide a strainer device, which is adapted to facilitate flushing and is particularly suited for installation in the cooling system of a liquid metal cooled fast breeding reactor. Structure: A casing accommodating a strainer and a blind plate for the selection of a flow path is provided at a suitable portion of the duct line. The blind plate is adapted to be rotated by an opening and closing means consisting of a rod. bellows, shaft and so forth. At the time of flushing, the duct line is sealed by the blind plate. (Nakamura, S.)

  7. Sharper angle, higher risk? The effect of cutting angle on knee mechanics in invasion sport athletes.

    Science.gov (United States)

    Schreurs, Mervin J; Benjaminse, Anne; Lemmink, Koen A P M

    2017-10-03

    Cutting is an important skill in team-sports, but unfortunately is also related to non-contact ACL injuries. The purpose was to examine knee kinetics and kinematics at different cutting angles. 13 males and 16 females performed cuts at different angles (45°, 90°, 135° and 180°) at maximum speed. 3D kinematics and kinetics were collected. To determine differences across cutting angles (45°, 90°, 135° and 180°) and sex (female, male), a 4×2 repeated measures ANOVA was conducted followed by post hoc comparisons (Bonferroni) with alpha level set at α≤0.05a priori. At all cutting angles, males showed greater knee flexion angles than females (pcutting angles with no differences in the amount of knee flexion -42.53°±8.95°, females decreased their knee flexion angle from -40.6°±7.2° when cutting at 45° to -36.81°±9.10° when cutting at 90°, 135° and 180° (pcutting towards sharper angles (pcutting angles and then stabilized compared to the 45° cutting angle (pcutting to sharper angles (pcutting angles demand different knee kinematics and kinetics. Sharper cutting angles place the knee more at risk. However, females and males handle this differently, which has implications for injury prevention. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Scalable devices

    KAUST Repository

    Krüger, Jens J.

    2014-01-01

    In computer science in general and in particular the field of high performance computing and supercomputing the term scalable plays an important role. It indicates that a piece of hardware, a concept, an algorithm, or an entire system scales with the size of the problem, i.e., it can not only be used in a very specific setting but it\\'s applicable for a wide range of problems. From small scenarios to possibly very large settings. In this spirit, there exist a number of fixed areas of research on scalability. There are works on scalable algorithms, scalable architectures but what are scalable devices? In the context of this chapter, we are interested in a whole range of display devices, ranging from small scale hardware such as tablet computers, pads, smart-phones etc. up to large tiled display walls. What interests us mostly is not so much the hardware setup but mostly the visualization algorithms behind these display systems that scale from your average smart phone up to the largest gigapixel display walls.

  9. Thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Takuro; Maki, Koichi.

    1997-01-01

    The present invention provides a thermonuclear device, in which integrity of a measuring device is kept, the reactor wall temperature and wear of armour materials are monitored accurately even under intense radiation rays, so that the flow rate of coolants and plasma power can be controlled by using the signals. Infrared rays generated from the surface of the armour materials disposed on a first wall are detected to measure the reactor wall temperature. Coolant flow rate and plasma power are controlled based on the obtained reactor wall temperature. In addition, infrared rays generated from the back of the armour materials are detected to obtain the surface temperature in order to avoid intense radiation rays from plasmas. The coolant flow rate and the plasma power are controlled based on the obtained temperature on the surface of the reactor thereby controlling the temperature of the first wall and the armour material to 300degC or lower in a case of the first wall made of stainless steel and 1000degC or lower in a case of the armour material made of graphite. (I.S.)

  10. Thermonuclear device

    International Nuclear Information System (INIS)

    Kuriyama, Masaaki; Yamamoto, Masahiro; Furuyama, Masayuki; Saito, Ryusei.

    1981-01-01

    Purpose: To enable the efficient and rapid cooling of a vacuum vessel by cooling with gas when the temperature of the vacuum vessel is higher than the boiling point of water and cooling with water when the temperature is lower than the boiling point of water. Constitution: A cooling pipe is provided through an insulating pipe on the outer periphery of a vacuum vessel. The cooling pipe communicates through a cooling gas valve and a coolant valve with a cooling gas supply device and a coolant supply device, and a heat exchanger is disposed at the pipe. When the vessel is higher than the boiling point of the coolant the coolant valve is closed and the cooling gas valve is opened and gas is supplied to cool the vessel. The gas is recoverd through a heat exchanger. On the other hand, when the temperature of vessel is lower than the boiling point of the coolant, the gas valve is closed, the coolant valve is opened, and the vessel is cooled with coolant. The vacuum vessel can be cooled for short time employing both the gas and the coolant together. (Yoshino, Y.)

  11. Irradiation device

    International Nuclear Information System (INIS)

    Suzuki, Toshimitsu.

    1989-01-01

    In an irradiation device for irradiating radiation rays such as electron beams to pharmaceuticals, etc., since the distribution of scanned electron rays was not monitored, the electron beam intensity could be determined only indirectly and irradiation reliability was not satisfactory. In view of the above, a plurality of monitor wires emitting secondary electrons are disposed in the scanning direction near a beam take-out window of a scanning duct, signals from the monitor wires are inputted into a display device such as a cathode ray tube, as well as signals from the monitor wires at the central portion are inputted into counting rate meters to measure the radiation dose as well. Since secondary electrons are emitted when electron beams pass through the monitor wires and the intensity thereof is in proportion with the intensity of incident electron beams, the distribution of the radiation dose can be monitored by measuring the intensity of the emitted secondary electrons. Further, uneven irradiation, etc. can also be monitored to make the radiation of irradiation rays reliable. (N.H.)

  12. Mineral extraction and transport device

    Energy Technology Data Exchange (ETDEWEB)

    Plaga, K.

    1991-08-21

    A device for the extraction and transport of stratified mineral deposits notably coal, having a transport run with lengths of transport troughing, an extraction run with lengths of extraction troughing, and a power-driven traction chain guided round return devices and carrying extraction bodies together with optional transport units. The transport and extraction troughing have guide members on which the extraction bodies and the transport units are guided with the aid of guide formations. Each extraction body consists of a headpiece having two laterally protruding guide formations, and an endpiece having two laterally protruding guide formations and a centrepiece. The headpiece and the endpiece are swivellably linked to the centrepiece through an axis running substantially at right angles to the traction axis of the traction chain and substantially at right angles to the floor of the lengths of transport troughing in the transport run. The centrepiece has an additional articulation about an axis substantially orthogonal to the swivel axis of the headpiece and the endpiece. Guide members are additionally provided in the vicinity of the return devices whereby the guide formations on each headpiece and endpiece receive continued guidance.

  13. Haptic device for telerobotic surgery

    Science.gov (United States)

    Salisbury, Curt; Salisbury, Jr., J. Kenneth

    2014-12-30

    A haptic device for telerobotic surgery, including a base; a linkage system having first and second linkage members coupled to the base; a motor that provides a motor force; a transmission including first and second driving pulleys arranged such that their faces form an angle and their axes form a plane, first and second idler pulleys offset from the plane and arranged between the first and second driving pulleys such that their axes divide the angle between the first and second driving pulleys, and a cable that traverses the first and second driving pulleys and the set of idler pulleys and transfers the motor force to the linkage system; an end effector coupled to distal ends of the first and second linkage members and maneuverable relative to the base; and a controller that modulates the motor force to simulate a body part at a point portion of the end effector.

  14. Page 1 '---------------------------- Presenting features ofprimary angle ...

    African Journals Online (AJOL)

    coma were assessed. The diagnosis of primary angle-closure glaucoma was made on presentation if the intra-ocular pressure was > 21 mmHg, or if a glaucomatous visual field was found, in the presence of a partially or totally closed angle or peripheral anterior synechiae. Provocation tests were not performed. Patients ...

  15. Gaugings at angles from orientifold reductions

    International Nuclear Information System (INIS)

    Roest, Diederik

    2009-01-01

    We consider orientifold reductions to N= 4 gauged supergravity in four dimensions. A special feature of this theory is that different factors of the gauge group can have relative angles with respect to the electro-magnetic SL(2) symmetry. These are crucial for moduli stabilization and de Sitter vacua. We show how such gaugings at angles generically arise in orientifold reductions.

  16. Automatic Cobb Angle Determination From Radiographic Images

    NARCIS (Netherlands)

    Sardjono, Tri Arief; Wilkinson, Michael H. F.; Veldhuizen, Albert G.; van Ooijen, Peter M. A.; Purnama, Ketut E.; Verkerke, Gijsbertus J.

    2013-01-01

    Study Design. Automatic measurement of Cobb angle in patients with scoliosis. Objective. To test the accuracy of an automatic Cobb angle determination method from frontal radiographical images. Summary of Background Data. Thirty-six frontal radiographical images of patients with scoliosis. Methods.

  17. Practical evaluation of action-angle variables

    International Nuclear Information System (INIS)

    Boozer, A.H.

    1984-02-01

    A practical method is described for establishing action-angle variables for a Hamiltonian system. That is, a given nearly integrable Hamiltonian is divided into an exactly integrable system plus a perturbation in action-angle form. The transformation of variables, which is carried out using a few short trajectory integrations, permits a rapid determination of trajectory properties throughout a phase space volume

  18. The Nasolabial Angle Among Patients with Total Cleft Lip and Palate.

    Science.gov (United States)

    Paradowska-Stolarz, Anna M; Kawala, Beata

    2015-01-01

    Nasolabial angle is the angle that is measured between points columella, subnasale and labiale superius. The reference values vary from 90 to 120 degrees (the mean value is 109.8 degrees). In some disorders, nasolabial angle might change. This influences the facial profile. One of such deformities are clefts. The nasolabial angle might be decreased in cleft patients due to deformation of the nose and upper lip that might be caused by the reconstructive surgical procedures performed. The aim of the study was to compare the nasolabial angle between the groups of patients with total clefts of the lip, alveolar bone and palate and healthy individuals. The cephalometric X-rays of 118 patients with clefts (73 boys and 45 girls) and 101 healthy individuals (32 boys and 69 girls) were taken into account to measure nasolabial angle and compared. In patients with cleft deformities, the nasolabial angle values were smaller than in healthy individuals. Among the patients with clefts, the ones with a bilateral type of deformity are characterized by the highest mean values of nasolabial angle. The angle is smaller in groups of girls when compared to boys. Nasolabial angle in patients with total clefts of lip, alveolar bone and palate is statistically smaller than in healthy individuals. This might be a result of either the deformation of the upper lip or (more probably) the nose. The orthodontic treatment should be individualized.

  19. Apparent contact angle and contact angle hysteresis on liquid infused surfaces.

    Science.gov (United States)

    Semprebon, Ciro; McHale, Glen; Kusumaatmaja, Halim

    2016-12-21

    We theoretically investigate the apparent contact angle and contact angle hysteresis of a droplet placed on a liquid infused surface. We show that the apparent contact angle is not uniquely defined by material parameters, but also has a dependence on the relative size between the droplet and its surrounding wetting ridge formed by the infusing liquid. We derive a closed form expression for the contact angle in the limit of vanishing wetting ridge, and compute the correction for small but finite ridge, which corresponds to an effective line tension term. We also predict contact angle hysteresis on liquid infused surfaces generated by the pinning of the contact lines by the surface corrugations. Our analytical expressions for both the apparent contact angle and contact angle hysteresis can be interpreted as 'weighted sums' between the contact angles of the infusing liquid relative to the droplet and surrounding gas phases, where the weighting coefficients are given by ratios of the fluid surface tensions.

  20. A lattice determination of gA and left angle x right angle from overlap fermions

    International Nuclear Information System (INIS)

    Guertler, M.; Schiller, A.; Streuer, T.; Freie Univ. Berlin

    2004-10-01

    We present results for the nucleon's axial charge g A and the first moment left angle x right angle of the unpolarized parton distribution function from a simulation of quenched overlap fermions. (orig.)

  1. Practical microwave electron devices

    CERN Document Server

    Meurant, Gerard

    2013-01-01

    Practical Microwave Electron Devices provides an understanding of microwave electron devices and their applications. All areas of microwave electron devices are covered. These include microwave solid-state devices, including popular microwave transistors and both passive and active diodes; quantum electron devices; thermionic devices (including relativistic thermionic devices); and ferrimagnetic electron devices. The design of each of these devices is discussed as well as their applications, including oscillation, amplification, switching, modulation, demodulation, and parametric interactions.

  2. Spectroscopic refractometer for transparent and absorbing liquids by reflection of white light near the critical angle

    International Nuclear Information System (INIS)

    Sánchez-Pérez, C.; García-Valenzuela, A.

    2012-01-01

    We propose and evaluate a spectroscopic refractometer device to measure the refractive index dispersion of transparent and absorbing solutions. The angle-dependent reflectivity of a white beam of light in an internal reflection configuration around the critical angle is spectrally analyzed. The refractive index in a wavelength range from 400 nm to 900 nm is obtained from the angle-reflectivity curve around the critical angle at each wavelength. The device does not use angle scanning mechanisms, decreasing considerably the complexity of the instrument in comparison to previous proposals. As a result, the measurements are obtained relatively fast. Nevertheless, a good experimental resolution in refractive index of about Δn ≈ 10 −4 at all the wavelengths is achieved in the case of transparent solutions. The calibration procedure of the device is discussed in detail. We also present measurements of the refractive index dispersion of rhodamine 6G-methanol solutions, which has a strong absorption band in the visible spectra.

  3. Laser peripheral iridoplasty for angle-closure.

    Science.gov (United States)

    Ng, Wai Siene; Ang, Ghee Soon; Azuara-Blanco, Augusto

    2012-02-15

    Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations.   To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles (PACs), PAC and PACG. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 12), MEDLINE (January 1950 to January 2012), EMBASE (January 1980 to January 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 5 January 2012. We included only randomised controlled trials (RCTs) in this review. Patients with narrow angles, PAC or PACG were eligible. We excluded studies that included only patients with acute presentations

  4. Contact Angles and Surface Tension of Germanium-Silicon Melts

    Science.gov (United States)

    Croell, A.; Kaiser, N.; Cobb, S.; Szofran, F. R.; Volz, M.; Rose, M. Franklin (Technical Monitor)

    2001-01-01

    Precise knowledge of material parameters is more and more important for improving crystal growth processes. Two important parameters are the contact (wetting) angle and the surface tension, determining meniscus shapes and surface-tension driven flows in a variety of methods (Czochralski, EFG, floating-zone, detached Bridgman growth). The sessile drop technique allows the measurement of both parameters simultaneously and has been used to measure the contact angles and the surface tension of Ge(1-x)Si(x) (0 less than or equal to x less than or equal to 1.3) alloys on various substrate materials. Fused quartz, Sapphire, glassy carbon, graphite, SiC, carbon-based aerogel, pyrolytic boron nitride (pBN), AIN, Si3N4, and polycrystalline CVD diamond were used as substrate materials. In addition, the effect of different cleaning procedures and surface treatments on the wetting behavior were investigated. Measurements were performed both under dynamic vacuum and gas atmospheres (argon or forming gas), with temperatures up to 1100 C. In some experiments, the sample was processed for longer times, up to a week, to investigate any changes of the contact angle and/or surface tension due to slow reactions with the substrate. For pure Ge, stable contact angles were found for carbon-based substrates and for pBN, for Ge(1-x)Si(x) only for pBN. The highest wetting angles were found for pBN substrates with angles around 170deg. For the surface tension of Ge, the most reliable values resulted in gamma(T) = (591- 0.077 (T-T(sub m)) 10(exp -3)N/m. The temperature dependence of the surface tension showed similar values for Ge(1-x)Si(x), around -0.08 x 10(exp -3)N/m K, and a compositional dependence of 2.2 x 10(exp -3)N/m at%Si.

  5. Location Estimation of Mobile Devices

    Directory of Open Access Journals (Sweden)

    Kamil ŽIDEK

    2009-06-01

    Full Text Available This contribution describes mathematical model (kinematics for Mobile Robot carriage. The mathematical model is fully parametric. Model is designed universally for any measures three or four wheeled carriage. The next conditions are: back wheels are driving-wheel, front wheels change angle of Robot turning. Position of the front wheel gives the actual position of the robot. Position of the robot is described by coordinates x, y and by angle of the front wheel α in reference position. Main reason for model implementation is indoor navigation. We need some estimation of robot position especially after turning of the Robot. Next use is for outdoor navigation especially for precising GPS information.

  6. Scoliosis angle. Conceptual basis and proposed definition

    Energy Technology Data Exchange (ETDEWEB)

    Marklund, T [Linkoepings Hoegskola (Sweden)

    1978-01-01

    The most commonly used methods of assessing the scoliotic deviation measure angles that are not clearly defined in relation to the anatomy of the patient. In order to give an anatomic basis for such measurements it is proposed to define the scoliotic deviation as the deviation the vertebral column makes with the sagittal plane. Both the Cobb and the Ferguson angles may be based on this definition. The present methods of measurement are then attempts to measure these angles. If the plane of these angles is parallel to the film, the measurement will be correct. Errors in the measurements may be incurred by the projection. A hypothetical projection, called a 'rectified orthogonal projection', is presented, which correctly represents all scoliotic angles in accordance with these principles. It can be constructed in practice with the aid of a computer and by performing measurements on two projections of the vertebral column; a scoliotic curve can be represented independent of the kyphosis and lordosis.

  7. The resection angle in apical surgery

    DEFF Research Database (Denmark)

    von Arx, Thomas; Janner, Simone F M; Jensen, Simon S

    2016-01-01

    OBJECTIVES: The primary objective of the present radiographic study was to analyse the resection angle in apical surgery and its correlation with treatment outcome, type of treated tooth, surgical depth and level of root-end filling. MATERIALS AND METHODS: In the context of a prospective clinical...... study, cone beam computed tomography (CBCT) scans were taken before and 1 year after apical surgery to measure the angle of the resection plane relative to the longitudinal axis of the root. Further, the surgical depth (distance from the buccal cortex to the most lingual/palatal point of the resection...... or with the retrofilling length. CONCLUSIONS: Statistically significant differences were observed comparing resection angles of different tooth groups. However, the angle had no significant effect on treatment outcome. CLINICAL RELEVANCE: Contrary to common belief, the resection angle in maxillary anterior teeth...

  8. Experimental study of crossing angle collision

    International Nuclear Information System (INIS)

    Chen, T.; Rice, D.; Rubin, D.; Sagan, D.; Tigner, M.

    1993-01-01

    The non-linear coupling due to the beam-beam interaction with crossing angle has been studied. The major effect of a small (∼12mrad) crossing angle is to excite 5Q x ±Q s =integer coupling resonance family on large amplitude particles, which results in bad lifetime. On the CESR, a small crossing angle (∼2.4mr) was created at the IP and a reasonable beam-beam tune-shift was achieved. The decay rate of the beam is measured as a function of horizontal tune with and without crossing angle. The theoretical analysis, simulation and experimental measurements have a good agreement. The resonance strength as a function of crossing angle is also measured

  9. Apparent Contact Angle and Contact Angle Hysteresis on Liquid Infused Surfaces

    OpenAIRE

    Semprebon, Ciro; McHale, Glen; Kusumaatmaja, Halim

    2016-01-01

    We theoretically investigate the apparent contact angle and contact angle hysteresis of a droplet placed on a liquid infused surface. We show that the apparent contact angle is not uniquely defined by material parameters, but also has a strong dependence on the relative size between the droplet and its surrounding wetting ridge formed by the infusing liquid. We derive a closed form expression for the contact angle in the limit of vanishing wetting ridge, and compute the correction for small b...

  10. Biomolecular detection device

    Science.gov (United States)

    Huo, Qisheng [Albuquerque, NM; Liu, Jun [Albuquerque, NM

    2008-10-21

    A device for detecting and measuring the concentration of biomolecules in solution, utilizing a conducting electrode in contact with a solution containing target biomolecules, with a film with controllable pore size distribution characteristics applied to at least one surface of the conducting electrode. The film is functionalized with probe molecules that chemically interact with the target biomolecules at the film surface, blocking indicator molecules present in solution from diffusing from the solution to the electrode, thereby changing the electrochemical response of the electrode.

  11. Thermonuclear device

    International Nuclear Information System (INIS)

    Furuyama, Masayuki.

    1979-01-01

    Purpose: To provide the subject device wherein a conductive short-circuiting ring is installed in the vicinity of the bonded part of bellows and thick portion of vacuum vessel in the small circumferential direction of torus, thereby to reduce the electromagnetic force generated at the bellows. Constitution: A conductive short-circuiting ring is provided in the vicinity of the connected part of a thick portion and bellows portion. By this organization, a saddle type current generated at the thick portion by a vertical magnetic field flows through the short-circuiting ring because the resistance at a part where the short-circuiting ring is provided is reduced, and the current flowing through the bellows is remarkably reduced. For this reason, the electromagnetic force generated at the bellows is reduced thereby to prevent the bellows from being destroyed by the electromagnetic force. (Yoshihara, H.)

  12. Electrophoresis device

    Science.gov (United States)

    Rhodes, P. H.; Snyder, R. S. (Inventor)

    1982-01-01

    A device for separating cellular particles of a sample substance into fractionated streams of different cellular species includes a casing having a distribution chamber, a separation chamber, and a collection chamber. The electrode chambers are separated from the separation chamber interior by means of passages such that flow variations and membrane variations around the slotted portion of the electrode chamber do not enduce flow perturbations into the laminar buffer curtain flowing in the separation chamber. The cellular particles of the sample are separated under the influence of the electrical field and the separation chamber into streams of different cellular species. The streams of separated cells enter a partition array in the collection chamber where they are fractionated and collected.

  13. Thermonuclear device

    International Nuclear Information System (INIS)

    Suzuki, Shohei

    1988-01-01

    Purpose: To obtain high voltage withstanding current introduction terminals not suffering from the effects of the reduction in the creeping voltage withstanding property by the application of magnetic fields. Constitution: This invention concerns a current introduction terminal for supplying electric current to coils for use in a thermonuclear device, etc. The conductor of the current introduction terminal on the side of vacuum is completely covered with solid insulator. This can eliminate the portion of securing the creeping withstanding voltage. The voltage withstanding characteristics of the solid insulator covering the portion of the conductor on the side of vacuum has a constant value irrespective of the atmosphere or the absence or presence of magnetic fields. Accordingly, the voltage withstanding characteristics of the current introduction terminal on the side of vacuum are determined by the property of the solid insulator, which is not reduced by the application of magnetic fields. (Ikeda, J.)

  14. Survival and Growth of Cottonwood Clones After Angle Planting and Base Angle Treatments

    Science.gov (United States)

    W.K. Randall; Harvey E. Kennedy

    1976-01-01

    Presently, commercial cottonwood plantations in the lower Mississippi Valley are established using vertically planted, unrooted cuttings with a flat (90°) base. Neither survival nor first-year growth of a group of six Stoneville clones was improved by angle planting or cutting base angles diagonally. For one clone, survival was significantly better when base angle was...

  15. Safety device of thermonuclear device

    International Nuclear Information System (INIS)

    Aoki, Isao; Ueda, Shuzo; Seki, Yasushi; Sakurai, Akiko; Kasahara, Fumio; Obara, Atsushi; Yamauchi, Michinori.

    1997-01-01

    The present invention provides a safety device against an event of intrusion of coolants in a vacuum vessel. Namely, a coolant supply system comprises cooling tubes for supplying coolants to main reactor structure components including a vacuum vessel. A detection means detects leakage of coolants in the vacuum vessel. A coolant supply control means controls the supply of coolants to the main reactor structural components based on the leakage detection signals of the detection means. A stagnated material discharging means discharges stagnated materials in the main reactor structural components caused by the leakage of coolants. The leakage of coolants (for example, water) in the vacuum vessel can thus be detected by the water detection device in the vacuum vessel. A control value of a coolant supply means is closed by the leakage detection signals. The supply of coolants to the main reactor structural components is restricted to suppress the leakage. The stagnated materials are discharged to a tank by way of a water draining valve. (I.S.)

  16. Using trajectory sensitivity analysis to find suitable locations of series compensators for improving rotor angle stability

    DEFF Research Database (Denmark)

    Nasri, Amin; Eriksson, Robert; Ghandhar, Mehrdad

    2014-01-01

    This paper proposes an approach based on trajectory sensitivity analysis (TSA) to find most suitable placement of series compensators in the power system. The main objective is to maximize the benefit of these devices in order to enhance the rotor angle stability. This approach is formulated...

  17. Neutron elastic scattering at very small angles

    CERN Multimedia

    2002-01-01

    This experiment will measure neutron-proton elastic scattering at very small angles and hence very small four-momentum transfer, |t|. The range of |t| depends on the incident neutron momentum of the events but the geometrical acceptance will cover the angular range 0.025 < $\\Theta_{lab}$ < 1.9 mrad. The higher figure could be extended to 8.4 mrad by changing the geometry of the experiment in a later phase. \\\\ \\\\ The neutron beam will be highly collimated and will be derived from a 400 GeV external proton beam of up to $4 \\times 10^{10}$ protons per pulse in the SPS North Area Hall 1. The hydrogen target will be gaseous, operating at 40 atm. pressure and acts as a multiwire proportional chamber to detect the recoil protons. The forward neutron will be detected and located by interaction in a neutron vertex detector and its energy measured by a conventional steel plate calorimeter. \\\\ \\\\ The experiment will cover the angular region of nucleon-nucleon scattering which is dominated by Coulomb scattering ...

  18. Asymmetric-cut variable-incident-angle monochromator.

    Science.gov (United States)

    Smither, R K; Graber, T J; Fernandez, P B; Mills, D M

    2012-03-01

    A novel asymmetric-cut variable-incident-angle monochromator was constructed and tested in 1997 at the Advanced Photon Source of Argonne National Laboratory. The monochromator was originally designed as a high heat load monochromator capable of handling 5-10 kW beams from a wiggler source. This was accomplished by spreading the x-ray beam out on the surface an asymmetric-cut crystal and by using liquid metal cooling of the first crystal. The monochromator turned out to be a highly versatile monochromator that could perform many different types of experiments. The monochromator consisted of two 18° asymmetrically cut Si crystals that could be rotated about 3 independent axes. The first stage (Φ) rotates the crystal around an axis perpendicular to the diffraction plane. This rotation changes the angle of the incident beam with the surface of the crystal without changing the Bragg angle. The second rotation (Ψ) is perpendicular to the first and is used to control the shape of the beam footprint on the crystal. The third rotation (Θ) controls the Bragg angle. Besides the high heat load application, the use of asymmetrically cut crystals allows one to increase or decrease the acceptance angle for crystal diffraction of a monochromatic x-ray beam and allows one to increase or decrease the wavelength bandwidth of the diffraction of a continuum source like a bending-magnet beam or a normal x-ray-tube source. When the monochromator is used in the doubly expanding mode, it is possible to expand the vertical size of the double-diffracted beam by a factor of 10-15. When this was combined with a bending magnet source, it was possible to generate an 8 keV area beam, 16 mm wide by 26 mm high with a uniform intensity and parallel to 1.2 arc sec that could be applied in imaging experiments.

  19. Increase of rotation angle of soil layers during plow operation

    Science.gov (United States)

    Vasilenko, VV; Afonichev, D. N.; Vasilenko, S. V.; Khakhulin, A. N.

    2018-03-01

    One of the advantages of plowing is the ability of the plow to hide the weed seeds deep into the soil. The depth of the embankment exceeds 10-12 cm, from there the weeds can not rise to the surface of the soil. They perish halfway. But for this, it is necessary to wrap the soil layers at an angle close to 180 °. Modern ploughs can not turn the layers of soil at an angle of more than 135 °, therefore the plow is required to be equipped with additional working elements. The aim of the study is to create an adaptation to the plow to expand the furrow before laying the next soil layer. In a wide furrow, the formation will completely tip, the previous layer will not interfere with it. The device is a set of vertical shields. Each shield is fixed behind the working body of the plow. It is installed with an angle of attack of 20-25 ° to move the previous layer to expand the furrow by 10-12 cm. The model and industrial samples of the plow have shown improved agrotechnical indicators. The average angle of the formation rotation was 177 °, the burial of plant residues in the soil increased from 61 to 99%. The field surface with blocks more than 5 cm decreased from 36.3 to 13.4%, the height of the ridges decreased from 7 to 4 cm. The force of soil pressure on the shield was measured by a strain gage. It is 130-330 N depending on the depth of processing and the speed of movement. The increase in power costs for the four-hull plow was 190-750 W. The coulters on the plow are unnecessary, and this saves energy more than its increase for shields.

  20. Creation of the {pi} angle standard for the flat angle measurements

    Energy Technology Data Exchange (ETDEWEB)

    Giniotis, V; Rybokas, M, E-mail: gi@ap.vtu.l, E-mail: MRybokas@gama.l [Department of Information Technologies, Vilnius Gediminas Technical University, Sauletekio al. 11, 10223 Vilnius-40 (Lithuania)

    2010-07-01

    Angle measurements are based mainly on multiangle prisms - polygons with autocollimators, rotary encoders for high accuracy and circular scales as the standards of the flat angle. Traceability of angle measurements is based on the standard of the plane angle - prism (polygon) calibrated at an appropriate accuracy. Some metrological institutions have established their special test benches (comparators) equipped with circular scales or rotary encoders of high accuracy and polygons with autocollimators for angle calibration purposes. Nevertheless, the standard (etalon) of plane angle - polygon has many restrictions for the transfer of angle unit - radian (rad) and other units of angle. It depends on the number of angles formed by the flat sides of the polygon that is restricted by technological and metrological difficulties related to the production and accuracy determination of the polygon. A possibility to create the standard of the angle equal to {pi} rad or half the circle or the full angle is proposed. It can be created by the circular scale with the rotation axis of very high accuracy and two precision reading instruments, usually, photoelectric microscopes (PM), placed on the opposite sides of the circular scale using the special alignment steps. A great variety of angle units and values can be measured and its traceability ensured by applying the third PM on the scale. Calibration of the circular scale itself and other scale or rotary encoder as well is possible using the proposed method with an implementation of {pi} rad as the primary standard angle. The method proposed enables to assure a traceability of angle measurements at every laboratory having appropriate environment and reading instruments of appropriate accuracy together with a rotary table with the rotation axis of high accuracy - rotation trajectory (runout) being in the range of 0.05 {mu}m. Short information about the multipurpose angle measurement test bench developed is presented.

  1. Assessment of novel digital and smartphone goniometers for measurement of canine stifle joint angles.

    Science.gov (United States)

    Freund, Kristin A; Kieves, Nina R; Hart, Juliette L; Foster, Sasha A; Jeffery, Unity; Duerr, Felix M

    2016-07-01

    OBJECTIVE To evaluate accuracy and reliability of 3 novel goniometers for measurement of canine stifle joint angles and compare the results with those obtained with a universal goniometer (UG). SAMPLE 8 pelvic limbs from 4 canine cadavers. PROCEDURES Each limb was secured to a wooden platform at 3 arbitrarily selected fixed stifle joint angles. Goniometry was performed with 2 smartphone-based applications (novel goniometers A and B), a digital goniometer (novel goniometer C), and a UG; 3 evaluators performed measurements in triplicate for each angle with each device. Results were compared with stifle joint angle measurements on radiographs (used as a gold standard). Accuracy was determined by calculation of bias and total error, coefficients of variation were calculated to estimate reliability, and strength of linear association between radiographic and goniometer measurements was assessed by calculation of correlation coefficients. RESULTS Mean coefficient of variation was lowest for the UG (4.88%), followed by novel goniometers B (7.37%), A (7.57%), and C (12.71%). Correlation with radiographic measurements was highest for the UG (r = 0.97), followed by novel goniometers B (0.93), A (0.90), and C (0.78). Constant bias was present for all devices except novel goniometer B. The UG and novel goniometer A had positive constant bias; novel goniometer C had negative constant bias. Total error at 50° and 100° angles was > 5% for all devices. CONCLUSIONS AND CLINICAL RELEVANCE None of the devices accurately represented radiographically measured stifle joint angles. Additional veterinary studies are indicated prior to the use of novel goniometers in dogs.

  2. Color printing enabled by phase change materials on paper substrate

    Directory of Open Access Journals (Sweden)

    Hong-Kai Ji

    2017-12-01

    Full Text Available We have coated phase change materials (PCMs on rough and flexible substrates to achieve multicolor changeable devices. The principle of the device is based on an earlier discovery that lights have strong interference effect in PCM films, leading to various colors by reflection. In this work, paper substrates are laminated by parylene layers to protect the device from water before coated with functional PCM films. The PCM-based color printing (PCP on paper is not affected by rough surfaces and shows a similar color appearance as that on smooth surfaces. In particular, the color-printed device can be patterned by UV lithography to display a clear and tunable optical image, and it exhibits a low sensitivity to the angle of view. Such PCP has potential applications for low-cost, disposable, and flexible displays.

  3. Color printing enabled by phase change materials on paper substrate

    Science.gov (United States)

    Ji, Hong-Kai; Tong, Hao; Qian, Hang; Liu, Nian; Xu, Ming; Miao, Xiang-Shui

    2017-12-01

    We have coated phase change materials (PCMs) on rough and flexible substrates to achieve multicolor changeable devices. The principle of the device is based on an earlier discovery that lights have strong interference effect in PCM films, leading to various colors by reflection. In this work, paper substrates are laminated by parylene layers to protect the device from water before coated with functional PCM films. The PCM-based color printing (PCP) on paper is not affected by rough surfaces and shows a similar color appearance as that on smooth surfaces. In particular, the color-printed device can be patterned by UV lithography to display a clear and tunable optical image, and it exhibits a low sensitivity to the angle of view. Such PCP has potential applications for low-cost, disposable, and flexible displays.

  4. Modified Angle's Classification for Primary Dentition.

    Science.gov (United States)

    Chandranee, Kaushik Narendra; Chandranee, Narendra Jayantilal; Nagpal, Devendra; Lamba, Gagandeep; Choudhari, Purva; Hotwani, Kavita

    2017-01-01

    This study aims to propose a modification of Angle's classification for primary dentition and to assess its applicability in children from Central India, Nagpur. Modification in Angle's classification has been proposed for application in primary dentition. Small roman numbers i/ii/iii are used for primary dentition notation to represent Angle's Class I/II/III molar relationships as in permanent dentition, respectively. To assess applicability of modified Angle's classification a cross-sectional preschool 2000 children population from central India; 3-6 years of age residing in Nagpur metropolitan city of Maharashtra state were selected randomly as per the inclusion and exclusion criteria. Majority 93.35% children were found to have bilateral Class i followed by 2.5% bilateral Class ii and 0.2% bilateral half cusp Class iii molar relationships as per the modified Angle's classification for primary dentition. About 3.75% children had various combinations of Class ii relationships and 0.2% children were having Class iii subdivision relationship. Modification of Angle's classification for application in primary dentition has been proposed. A cross-sectional investigation using new classification revealed various 6.25% Class ii and 0.4% Class iii molar relationships cases in preschool children population in a metropolitan city of Nagpur. Application of the modified Angle's classification to other population groups is warranted to validate its routine application in clinical pediatric dentistry.

  5. Modified angle's classification for primary dentition

    Directory of Open Access Journals (Sweden)

    Kaushik Narendra Chandranee

    2017-01-01

    Full Text Available Aim: This study aims to propose a modification of Angle's classification for primary dentition and to assess its applicability in children from Central India, Nagpur. Methods: Modification in Angle's classification has been proposed for application in primary dentition. Small roman numbers i/ii/iii are used for primary dentition notation to represent Angle's Class I/II/III molar relationships as in permanent dentition, respectively. To assess applicability of modified Angle's classification a cross-sectional preschool 2000 children population from central India; 3–6 years of age residing in Nagpur metropolitan city of Maharashtra state were selected randomly as per the inclusion and exclusion criteria. Results: Majority 93.35% children were found to have bilateral Class i followed by 2.5% bilateral Class ii and 0.2% bilateral half cusp Class iii molar relationships as per the modified Angle's classification for primary dentition. About 3.75% children had various combinations of Class ii relationships and 0.2% children were having Class iii subdivision relationship. Conclusions: Modification of Angle's classification for application in primary dentition has been proposed. A cross-sectional investigation using new classification revealed various 6.25% Class ii and 0.4% Class iii molar relationships cases in preschool children population in a metropolitan city of Nagpur. Application of the modified Angle's classification to other population groups is warranted to validate its routine application in clinical pediatric dentistry.

  6. Preferred nasolabial angle in Middle Eastern population.

    Science.gov (United States)

    Alharethy, Sami

    2017-05-01

    To define the preferred nasolabial angle measurement in Middle Eastern population. An observational study was conducted from January 2012 to January 2016 at the Department of Otolaryngology, Head and Neck Surgery, King Abdulaziz University Hospital, King Saud University, Riyadh, Kingdom of Saudi Arabia. A total of 1027 raters, 506 males, and 521 females were asked to choose the most ideal nasolabial angle for 5 males and 5 females lateral photographs whose nasolabial angle were modified with Photoshop into the following angles (85°, 90°, 95°, 100°, 105°, and 110°). Male raters preferred the angle of 89.5° ± 3.5° (mean ± SD) for males and 90.8° ± 5.6° for females. While female raters preferred the angle of 89.3° ± 3.8° for males and 90.5° ± 4.8° for females. ANOVA test compare means among groups: p: 0.342, and there is no statistically significant difference between groups. The results of our study showed an even more acute angles than degrees found in the literature. It shows that what young generation in our region prefers and clearly reflects that what could be explained as under rotation of the nasal tip in other cultures is just the ideal for some Middle Eastern population.

  7. Device for detecting the specific gravity of a liquid. [Patent application

    Science.gov (United States)

    Derouin, C.R.; Kerwin, W.J.; McCormick, J.B.; Bobbett, R.E.

    1980-11-18

    A device for detecting the specific gravity of a liquid and a device for detecting the state of charge of a liquid phase electrolyte battery are described. In one embodiment of the present invention, a change in the critical angle of total internal reflection is utilized to determine the index of refraction of the liquid to be measured. It is shown that the index of refraction of the liquid is a function of the specific gravity of the liquid. In applications for measuring the state of charge of a battery, the specific gravity is proportional to the state of charge of the battery. A change in intensity of rays intersecting an interface surface indicates the critical angle which is a direct indication of the specific gravity of the liquid and the state of charge of a battery. In another embodiment, a light beam is projected through a transparent medium and then through a portion of the liquid to be measured. A change in refraction due to a change in the index of refraction of the liquid produces a deflection of the beam which is measured by a detector. The magnitude of deflection of the beam is directly proportional to the specific gravity of the liquid and the state of charge of a battery.

  8. Extraglottic airway devices: technology update

    Directory of Open Access Journals (Sweden)

    Sharma B

    2017-08-01

    Full Text Available Bimla Sharma, Chand Sahai, Jayashree Sood Department of Anaesthesiology, Pain and Perioperative Medicine, Sir Ganga Ram Hospital, New Delhi, India Abstract: Extraglottic airway devices (EADs have revolutionized the field of airway management. The invention of the laryngeal mask airway was a game changer, and since then, there have been several innovations to improve the EADs in design, functionality, safety and construction material. These have ranged from changes in the shape of the mask, number of cuffs and material used, like rubber, polyvinylchloride and latex. Phthalates, which were added to the construction material in order to increase device flexibility, were later omitted when this chemical was found to have serious adverse reproductive outcomes. The various designs brought out by numerous companies manufacturing EADs resulted in the addition of several devices to the airway market. These airway devices were put to use, many of them with inadequate or no evidence base regarding their efficacy and safety. To reduce the possibility of compromising the safety of the patient, the Difficult Airway Society (DAS formed the Airway Device Evaluation Project Team (ADEPT to strengthen the evidence base for airway equipment and vet the new extraglottic devices. A preuse careful analysis of the design and structure may help in better understanding of the functionality of a particular device. In the meantime, the search for the ideal EAD continues. Keywords: extraglottic airway devices, laryngeal mask airway, other extraglottic airway devices, safety, technology update

  9. Tuning for optimal performance in angle control, uniformity, and energy purity

    International Nuclear Information System (INIS)

    Liebert, Reuel B.; Olson, Joseph C.; Arevalo, Edwin A.; Downey, Daniel F.

    2005-01-01

    Advances in reducing the sizes of device structures and line widths place increasing demands on the accuracy of dopant placement and the control of dopant motion during activation anneals. Serial process high current ion implantation systems seek to produce beams in which the angles are controlled to high precision avoiding the angles introduced by conical structures used for holding wafers on spinning discs in batch systems. However, ion optical corrections and control of incident beam angle, dose uniformity, high throughput and energy purity often present apparently contradictory requirements in machine design. Data is presented to illustrate that tuning procedures can be used to simultaneously optimize angle purity in both x and y planes as well as control energy purity and dose uniformity

  10. SU-E-T-195: Gantry Angle Dependency of MLC Leaf Position Error

    Energy Technology Data Exchange (ETDEWEB)

    Ju, S; Hong, C; Kim, M; Chung, K; Kim, J; Han, Y; Ahn, S; Chung, S; Shin, E; Shin, J; Kim, H; Kim, D; Choi, D [Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2014-06-01

    Purpose: The aim of this study was to investigate the gantry angle dependency of the multileaf collimator (MLC) leaf position error. Methods: An automatic MLC quality assurance system (AutoMLCQA) was developed to evaluate the gantry angle dependency of the MLC leaf position error using an electronic portal imaging device (EPID). To eliminate the EPID position error due to gantry rotation, we designed a reference maker (RM) that could be inserted into the wedge mount. After setting up the EPID, a reference image was taken of the RM using an open field. Next, an EPID-based picket-fence test (PFT) was performed without the RM. These procedures were repeated at every 45° intervals of the gantry angle. A total of eight reference images and PFT image sets were analyzed using in-house software. The average MLC leaf position error was calculated at five pickets (-10, -5, 0, 5, and 10 cm) in accordance with general PFT guidelines using in-house software. This test was carried out for four linear accelerators. Results: The average MLC leaf position errors were within the set criterion of <1 mm (actual errors ranged from -0.7 to 0.8 mm) for all gantry angles, but significant gantry angle dependency was observed in all machines. The error was smaller at a gantry angle of 0° but increased toward the positive direction with gantry angle increments in the clockwise direction. The error reached a maximum value at a gantry angle of 90° and then gradually decreased until 180°. In the counter-clockwise rotation of the gantry, the same pattern of error was observed but the error increased in the negative direction. Conclusion: The AutoMLCQA system was useful to evaluate the MLC leaf position error for various gantry angles without the EPID position error. The Gantry angle dependency should be considered during MLC leaf position error analysis.

  11. Estimation of Sideslip Angle Based on Extended Kalman Filter

    Directory of Open Access Journals (Sweden)

    Yupeng Huang

    2017-01-01

    Full Text Available The sideslip angle plays an extremely important role in vehicle stability control, but the sideslip angle in production car cannot be obtained from sensor directly in consideration of the cost of the sensor; it is essential to estimate the sideslip angle indirectly by means of other vehicle motion parameters; therefore, an estimation algorithm with real-time performance and accuracy is critical. Traditional estimation method based on Kalman filter algorithm is correct in vehicle linear control area; however, on low adhesion road, vehicles have obvious nonlinear characteristics. In this paper, extended Kalman filtering algorithm had been put forward in consideration of the nonlinear characteristic of the tire and was verified by the Carsim and Simulink joint simulation, such as the simulation on the wet cement road and the ice and snow road with double lane change. To test and verify the effect of extended Kalman filtering estimation algorithm, the real vehicle test was carried out on the limit test field. The experimental results show that the accuracy of vehicle sideslip angle acquired by extended Kalman filtering algorithm is obviously higher than that acquired by Kalman filtering in the area of the nonlinearity.

  12. Angle-dependent bandgap engineering in gated graphene superlattices

    Energy Technology Data Exchange (ETDEWEB)

    García-Cervantes, H.; Sotolongo-Costa, O. [Centro de Investigación en Ciencias, IICBA, Universidad Autónoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, 62209 Cuernavaca, Morelos, México (Mexico); Gaggero-Sager, L. M. [CIICAp, IICBA, Universidad Autónoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, 62209 Cuernavaca, Morelos, México (Mexico); Naumis, G. G. [Instituto Física, Depto. de Física-Química, Universidad Nacional Autónoma de México (UNAM). Apdo. Postal 20-364, 01000, México D.F., México (Mexico); Rodríguez-Vargas, I., E-mail: isaac@fisica.uaz.edu.mx [Centro de Investigación en Ciencias, IICBA, Universidad Autónoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, 62209 Cuernavaca, Morelos, México (Mexico); Unidad Académica de Física, Universidad Autónoma de Zacatecas, Calzada Solidaridad Esquina Con Paseo La Bufa S/N, 98060 Zacatecas, Zac., México (Mexico)

    2016-03-15

    Graphene Superlattices (GSs) have attracted a lot of attention due to its peculiar properties as well as its possible technological implications. Among these characteristics we can mention: the extra Dirac points in the dispersion relation and the highly anisotropic propagation of the charge carriers. However, despite the intense research that is carried out in GSs, so far there is no report about the angular dependence of the Transmission Gap (TG) in GSs. Here, we report the dependence of TG as a function of the angle of the incident Dirac electrons in a rather simple Electrostatic GS (EGS). Our results show that the angular dependence of the TG is intricate, since for moderated angles the dependence is parabolic, while for large angles an exponential dependence is registered. We also find that the TG can be modulated from meV to eV, by changing the structural parameters of the GS. These characteristics open the possibility for an angle-dependent bandgap engineering in graphene.

  13. Angle-dependent bandgap engineering in gated graphene superlattices

    International Nuclear Information System (INIS)

    García-Cervantes, H.; Sotolongo-Costa, O.; Gaggero-Sager, L. M.; Naumis, G. G.; Rodríguez-Vargas, I.

    2016-01-01

    Graphene Superlattices (GSs) have attracted a lot of attention due to its peculiar properties as well as its possible technological implications. Among these characteristics we can mention: the extra Dirac points in the dispersion relation and the highly anisotropic propagation of the charge carriers. However, despite the intense research that is carried out in GSs, so far there is no report about the angular dependence of the Transmission Gap (TG) in GSs. Here, we report the dependence of TG as a function of the angle of the incident Dirac electrons in a rather simple Electrostatic GS (EGS). Our results show that the angular dependence of the TG is intricate, since for moderated angles the dependence is parabolic, while for large angles an exponential dependence is registered. We also find that the TG can be modulated from meV to eV, by changing the structural parameters of the GS. These characteristics open the possibility for an angle-dependent bandgap engineering in graphene.

  14. Predicting bifurcation angle effect on blood flow in the microvasculature.

    Science.gov (United States)

    Yang, Jiho; Pak, Y Eugene; Lee, Tae-Rin

    2016-11-01

    Since blood viscosity is a basic parameter for understanding hemodynamics in human physiology, great amount of research has been done in order to accurately predict this highly non-Newtonian flow property. However, previous works lacked in consideration of hemodynamic changes induced by heterogeneous vessel networks. In this paper, the effect of bifurcation on hemodynamics in a microvasculature is quantitatively predicted. The flow resistance in a single bifurcation microvessel was calculated by combining a new simple mathematical model with 3-dimensional flow simulation for varying bifurcation angles under physiological flow conditions. Interestingly, the results indicate that flow resistance induced by vessel bifurcation holds a constant value of approximately 0.44 over the whole single bifurcation model below diameter of 60μm regardless of geometric parameters including bifurcation angle. Flow solutions computed from this new model showed substantial decrement in flow velocity relative to other mathematical models, which do not include vessel bifurcation effects, while pressure remained the same. Furthermore, when applying the bifurcation angle effect to the entire microvascular network, the simulation results gave better agreements with recent in vivo experimental measurements. This finding suggests a new paradigm in microvascular blood flow properties, that vessel bifurcation itself, regardless of its angle, holds considerable influence on blood viscosity, and this phenomenon will help to develop new predictive tools in microvascular research. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Anthropometric characterisation of elbow angles and lines among Indian children

    Directory of Open Access Journals (Sweden)

    Bhanu Awasthi

    2017-01-01

    Full Text Available Background: For understanding injuries in paediatric elbow and checking the degree of reduction after manipulation, various radiological criteria using anthropometric parameters are used. Since anthropometric parameters of Caucasians are different from European and Mongoloids, their parameters cannot be applied on our population. Hence, there is a need to characterise anthropometric parameters of elbow among children in the Indian population. Materials and Methods: The study population comprised all cases of injury to the elbow joint between 3 and 13 years of age reporting to the Department of Orthopaedics during the study. The X-rays films were preserved, and the angles and lines (as anthropometric parameters were drawn on the radiographs. Results: Mean ± (standard deviation [SD] for Baumann angle in children included in this study was 75° ± 4.70°. Mean ± (SD of Baumann angle in males was 76° ± 4.44° and females was 74° ± 5.37°. Mean ± (SD for lateral capitellohumeral angle in children from 3 to 13 years of age was 49 ± 5.75. Conclusions: As the values of normal side have been found to affect the functional and cosmetic outcome of the affected extremity, slight changes in values of our population in comparison to that of the Western population can significantly affect the outcome.

  16. Magnetic nanoparticles studied by small angle X-ray scattering

    International Nuclear Information System (INIS)

    Oliveira, Cristiano Luis Pinto; Antonel, Soledad; Negri, Martin

    2011-01-01

    Full text: Magnetic nanoparticles have attracted much attention in the past decades because of their potential applications in high-density magnetic recording, magnetic fluids, data storage, spin-tronics, solar cells, sensors and catalysis. Among the magnetic nanoparticles, cobalt ferrite (CoFe 2 O 4 ) has been widely studied due to high electromagnetic performance, excellent chemical stability, mechanical hardness, and high cubic magnetocrystalline anisotropy. These properties make it a promising candidate for many applications in commercial electronics such as video, audio tapes, high-density digital recording media, and magnetic fluids. Other interesting application is the use of magnetic nanocompounds in the design of magneto elastomers. Magnetoelastomers are dispersions of magnetic particles into an elastomer polymer matrix. These materials are highly promising for applications in the development of sensors and actuators, mainly because of the possibility to optimize the quality parameters of the devices by systematically changing the chemical nature of both the inorganic particles and the organic polymeric matrix, with the consequent modification of the magnetic, electric and elastic properties. Moreover, nanoparticles of cobalt-iron oxides (cobalt ferrite, CoFe 2 O 4 ) appears as very interesting compounds for magnetoelasticity, not only because present magnetic anisotropy, moderate-high magnetization and high coercitivity at room temperature, but also because the possibility to modulate its magnetic properties by chemical synthesis, that is by synthesizing nanoparticles of different sizes having thus not only different magnetic parameters but also different magnetic behavior (superparamagnetism or ferromagnetism). That means that most of the magnetic properties of CoFe 2 O 4 ferrite strongly depend on the size and shape of the nanoparticles, which are closely related to the method of preparation. On the other hand, nickel nanoparticles are very interesting

  17. Magnetic nanoparticles studied by small angle X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Cristiano Luis Pinto [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica. Grupo de Fluidos Complexos; Antonel, Soledad; Negri, Martin [Universidad de Buenos Aires (UBA) (Argentina). Facultad de Ciencias Exactas y Naturales. Dept. de Quimica Inorganica, Analitica y Quimica Fisica

    2011-07-01

    Full text: Magnetic nanoparticles have attracted much attention in the past decades because of their potential applications in high-density magnetic recording, magnetic fluids, data storage, spin-tronics, solar cells, sensors and catalysis. Among the magnetic nanoparticles, cobalt ferrite (CoFe{sub 2}O{sub 4}) has been widely studied due to high electromagnetic performance, excellent chemical stability, mechanical hardness, and high cubic magnetocrystalline anisotropy. These properties make it a promising candidate for many applications in commercial electronics such as video, audio tapes, high-density digital recording media, and magnetic fluids. Other interesting application is the use of magnetic nanocompounds in the design of magneto elastomers. Magnetoelastomers are dispersions of magnetic particles into an elastomer polymer matrix. These materials are highly promising for applications in the development of sensors and actuators, mainly because of the possibility to optimize the quality parameters of the devices by systematically changing the chemical nature of both the inorganic particles and the organic polymeric matrix, with the consequent modification of the magnetic, electric and elastic properties. Moreover, nanoparticles of cobalt-iron oxides (cobalt ferrite, CoFe{sub 2}O{sub 4}) appears as very interesting compounds for magnetoelasticity, not only because present magnetic anisotropy, moderate-high magnetization and high coercitivity at room temperature, but also because the possibility to modulate its magnetic properties by chemical synthesis, that is by synthesizing nanoparticles of different sizes having thus not only different magnetic parameters but also different magnetic behavior (superparamagnetism or ferromagnetism). That means that most of the magnetic properties of CoFe{sub 2}O{sub 4} ferrite strongly depend on the size and shape of the nanoparticles, which are closely related to the method of preparation. On the other hand, nickel

  18. Criticality alarm device

    International Nuclear Information System (INIS)

    Kasai, Kenji.

    1994-01-01

    The device of the present invention is utilized, for example, to a reprocessing facility for storing and processing nuclear fuels and measures and controls the nuclear fuel assembly system so as not to exceed criticality. That is, a conventional criticality alarm device applies a predetermined processing to neutron fluxes generated from a nuclear fuel assembly system containing nuclear fuels and outputs an alarm. The device of the present invention comprises (1) a neutron flux supply source for increasing and decreasing neutron fluxes periodically and supplying them to nuclear fuel assemblies, (2) a detector for detecting neutron fluxes in the nuclear fuel assemblies, (3) a critical state judging section for judging the critical state of the nuclear fuel assemblies based on the periodically changing signals obtained from the detector (2) and (4) an alarm section for outputting criticality alarms depending on the result of the judgement. The device of the present invention can accurately recognize the critical state of the nuclear fuel assembly system and can forecast reaching of the nuclear fuel assembly to criticality or prompt neutron critical state. (I.S.)

  19. Programmable ubiquitous telerobotic devices

    Science.gov (United States)

    Doherty, Michael; Greene, Matthew; Keaton, David; Och, Christian; Seidl, Matthew L.; Waite, William; Zorn, Benjamin G.

    1997-12-01

    We are investigating a field of research that we call ubiquitous telepresence, which involves the design and implementation of low-cost robotic devices that can be programmed and operated from anywhere on the Internet. These devices, which we call ubots, can be used for academic purposes (e.g., a biologist could remote conduct a population survey), commercial purposes (e.g., a house could be shown remotely by a real-estate agent), and for recreation and education (e.g., someone could tour a museum remotely). We anticipate that such devices will become increasingly common due to recent changes in hardware and software technology. In particular, current hardware technology enables such devices to be constructed very cheaply (less than $500), and current software and network technology allows highly portable code to be written and downloaded across the Internet. In this paper, we present our prototype system architecture, and the ubot implementation we have constructed based on it. The hardware technology we use is the handy board, a 6811-based controller board with digital and analog inputs and outputs. Our software includes a network layer based on TCP/IP and software layers written in Java. Our software enables users across the Internet to program the behavior of the vehicle and to receive image feedback from a camera mounted on it.

  20. Magnetic-bubble devices

    International Nuclear Information System (INIS)

    Fairholme, R.J.

    1978-01-01

    Magnetic bubbles were first described only ten years ago when research workers were discussing orthoferrites containing μm diameter bubbles. However, problems of material fabrication limit crystals to a few mm across which severely curtailed device development. Since then materials have changed and rare-earth-iron garnet films can be grown up 3 inches in diameter with bubble diameters down to sizes below 1 μm. The first commercial products have device capacities in the range 64 000 to 100 000 bits with bubble diameters between 4 and 6 μm. Chip capacities of 1 Mbit are presently under development in the laboratory, as are new techniques to use submicrometre bubbles. The operation and fabrication of a bubble device is described using the serial loop devices currently being manufactured at Plessey as models. Chip organization is one important variable which directly affects the access time. A range of access times and capacities is available which offers a wide range of market opportunities, ranging from consumer products to fixed head disc replacements. some of the application areas are described. (author)

  1. Computing angle of arrival of radio signals

    Science.gov (United States)

    Borchardt, John J.; Steele, David K.

    2017-11-07

    Various technologies pertaining to computing angle of arrival of radio signals are described. A system that is configured for computing the angle of arrival of a radio signal includes a cylindrical sheath wrapped around a cylindrical object, where the cylindrical sheath acts as a ground plane. The system further includes a plurality of antennas that are positioned about an exterior surface of the cylindrical sheath, and receivers respectively coupled to the antennas. The receivers output measurements pertaining to the radio signal. A processing circuit receives the measurements and computes the angle of arrival of the radio signal based upon the measurements.

  2. Measurement of the infrared optical constants for spectral modeling: n and k values for (NH4)2SO4 via single-angle reflectance and ellipsometric methods

    Energy Technology Data Exchange (ETDEWEB)

    Blake, Thomas A.; Brauer, Carolyn S.; Kelly-Gorham, Molly Rose K.; Burton, Sarah D.; Bliss, Mary; Myers, Tanya L.; Johnson, Timothy J.; Tiwald, Thomas E.

    2017-05-05

    The optical constants n and k can be used to model infrared spectra, including refraction, absorption, reflectance, and emissivity, but obtaining reliable values for solid materials (pure or otherwise) presents a challenge: In the past, the best results for n and k have been obtained from bulk, homogeneous materials, free of defects. That is, materials where the Fresnel equations are operant since there is no light scattering. Since it is often not possible to obtain a pure macroscopic (crystalline) material, it may be possible to press the material into a (uniform, void-free) disk. We have recently been able to do this with ammonium sulfate powder and then measured the n & k values via two independent methods: 1) Ellipsometry - which measures the changes in amplitude and phase of light reflected from the material of interest as a function of wavelength and angle of incidence, and 2) Single angle specular reflectance with an FT spectrometer using a specular reflectance device within an FT instrument which measures the change in amplitude of light reflected from the material of interest as a function of wavelength and angle of incidence over a wide wavelength range. The quality of the derived n & k values was tested by generating the reflectance spectra of the pellet and comparing to the calculated to measured reflectance spectra of the pure material which has been previously published. The comparison to literature values showed good accuracy and good agreement, indicating promise to measure other materials by such methods.

  3. Cobb Angle Changes in Thoracic and Lumbar Spine Fractures ...

    African Journals Online (AJOL)

    The annual incidence of spinal column fracture is 350 per million populations. with Motor vehicular accident being the major single cause of spine injuries. The victims are predominantly young and male. The aim of this study to evaluate the clinical outcome of conservative treatment of closed thoracic and lumbar spine ...

  4. A novel method for device-related electroencephalography artifact suppression to explore cochlear implant-related cortical changes in single-sided deafness.

    Science.gov (United States)

    Kim, Kyungsoo; Punte, Andrea Kleine; Mertens, Griet; Van de Heyning, Paul; Park, Kyung-Joon; Choi, Hongsoo; Choi, Ji-Woong; Song, Jae-Jin

    2015-11-30

    Quantitative electroencephalography (qEEG) is effective when used to analyze ongoing cortical oscillations in cochlear implant (CI) users. However, localization of cortical activity in such users via qEEG is confounded by the presence of artifacts produced by the device itself. Typically, independent component analysis (ICA) is used to remove CI artifacts in auditory evoked EEG signals collected upon brief stimulation and it is effective for auditory evoked potentials (AEPs). However, AEPs do not reflect the daily environments of patients, and thus, continuous EEG data that are closer to such environments are desirable. In this case, device-related artifacts in EEG data are difficult to remove selectively via ICA due to over-completion of EEG data removal in the absence of preprocessing. EEGs were recorded for a long time under conditions of continuous auditory stimulation. To obviate the over-completion problem, we limited the frequency of CI artifacts to a significant characteristic peak and apply ICA artifact removal. Topographic brain mapping results analyzed via band-limited (BL)-ICA exhibited a better energy distribution, matched to the CI location, than data obtained using conventional ICA. Also, source localization data verified that BL-ICA effectively removed CI artifacts. The proposed method selectively removes CI artifacts from continuous EEG recordings, while ICA removal method shows residual peak and removes important brain activity signals. CI artifacts in EEG data obtained during continuous passive listening can be effectively removed with the aid of BL-ICA, opening up new EEG research possibilities in subjects with CIs. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Thermonuclear device

    International Nuclear Information System (INIS)

    Suzuki, Shohei.

    1980-01-01

    Purpose: To improve the plasma confining efficiency in a thermonuclear device having magnet coils using super-conducting wires by decreasing the uneven magnetic field resulted from current supply terminals and wirings. Constitution: Current introduction terminals of magnet coils using superconducting wires are short circuitted with a superconducting short circuit wire. Upon supplying current to the coils, the resistance of the coils is rendered superconductive and the resistance of the short circuit wire is rendered normally conductive heated by a heater and the switch is closed. In this case, most parts of the current are flown through the resistance of the coils and the switch is opened when the current arrives at a predetermined value to render the resistance of the short circuit wire superconductive. Then, the current transfers from the thyristor power source to the resistance of the short circuit wire, whereby the resistance of the coils and that of the short circuit wire from a permanent current loop. In this conditions, since current flows through the short circuit wire and the coils and not to the current introduction terminals, no uniform magnetic field is generated. (Kawakami, Y.)

  6. Reluctance device

    International Nuclear Information System (INIS)

    Claridge, A.N.; Smith, A.J.

    1983-01-01

    A reluctance device comprises two or more phases, each of which has a rotor mounted for rotation within a tubular member and an annular stator positioned externally of the tubular member. The rotor and the internal surface of the tubular member are each provided with aligned, axially spaced apart annular arrays of teeth, the teeth on the rotor confronting those on the tubular member in radially spaced apart relationship. The stator encloses a coil which, when electrically energised, creates a plurality of magnetic flux paths each of which extends radially between the rotor and stator via the confronting teeth and the tubular member, and axially along both the rotor and the portion of the stator located radially outwardly of the coil. The portion of the tubular member intermediate the teeth thereon is provided with a non-magnetic insert in order to resist the axial passage of magnetic flux therethrough. In one of the claims, the tubular member comprises a portion of a nuclear reactor which is adapted to contain a reactor control rod, the rotor constituting a portion of the drive mechanism for the control rod contained in operation within the tubular member. (author)

  7. Reactor shutdown device

    Energy Technology Data Exchange (ETDEWEB)

    Harada, Kiyoshi; Aono, Hidehiro [Hitachi Ltd., Tokyo (Japan); Fujita, Kaoru; Ishikawa, Tsuyoshi

    1996-02-20

    The present invention concerns a reactor shutdown device of a LMFBR type reactor, and provides a magnetic circuit having a sharp changing property of holding force relative to temperature change. Namely, a magnetic bridge is attached to a portion of the magnetic circuit. Then, required conditions are satisfied. Alternatively, even if the temperature dependent change of magnetic saturation of a temperature sensing alloy itself is somewhat moderated, the holding force from an erroneous dropping preventive temperature to a separating temperature can be abruptly reduced while keeping the holding force at a temperature lower than the erroneous dropping preventive temperature. Provision of the magnetic bridge increases the temperature dependent change of the holding force of the entire magnetic circuit. As a result, margin for the design of the temperature sensing alloy is extended. Actual design is enabled, and the range for selecting the temperature sensing alloy can be enlarged. (I.S.).

  8. Reactor shutdown device

    International Nuclear Information System (INIS)

    Harada, Kiyoshi; Aono, Hidehiro; Fujita, Kaoru; Ishikawa, Tsuyoshi.

    1996-01-01

    The present invention concerns a reactor shutdown device of a LMFBR type reactor, and provides a magnetic circuit having a sharp changing property of holding force relative to temperature change. Namely, a magnetic bridge is attached to a portion of the magnetic circuit. Then, required conditions are satisfied. Alternatively, even if the temperature dependent change of magnetic saturation of a temperature sensing alloy itself is somewhat moderated, the holding force from an erroneous dropping preventive temperature to a separating temperature can be abruptly reduced while keeping the holding force at a temperature lower than the erroneous dropping preventive temperature. Provision of the magnetic bridge increases the temperature dependent change of the holding force of the entire magnetic circuit. As a result, margin for the design of the temperature sensing alloy is extended. Actual design is enabled, and the range for selecting the temperature sensing alloy can be enlarged. (I.S.)

  9. Improvement of a device for region radiation survey

    International Nuclear Information System (INIS)

    Poltinnikov, S.A.

    1978-01-01

    The electromechnanical device based on coding the turning angle of an automobile wheel by the number of electric pulses controlling the step motor of a film gate of gamma radiometer is proposed. The device is intended for automatizing recordings of gamma-radiation levels depending on a certain distance in a given terrain. The device has been tested at car speeds from 10 to 80 km/hr

  10. Protection device for a thermonuclear device

    International Nuclear Information System (INIS)

    Kawashima, Shuichi.

    1986-01-01

    Purpose: To exactly detect the void coefficients of coolants even under high magnetic fields thereby detect the overheat of a thermonuclear device at an early stage. Constitution: The protecting device of this invention comprises a laser beam generation device, a laser beam detection device and an accident detection device. The laser generation device always generates laser beams, which are permeated through coolants and detected by the laser beam detection device, the optical amount of which is transmitted to the accident detection device. The accident detection device judges the excess or insufficiency of the detected optical amount with respect to the optical amount of the laser beams under the stationary state as a reference and issues an accident signal. Since only the optical cables that do not undergo the effect of the magnetic fields are exposed to high magnetic fields in the protection device of this invention, a high reliability can be maintained. (Kamimura, M.)

  11. Modelling of surface evolution of rough surface on divertor target in fusion devices

    International Nuclear Information System (INIS)

    Dai, Shuyu; Liu, Shengguang; Sun, Jizhong; Kirschner, A.; Kawamura, G.; Tskhakaya, D.; Ding, Rui; Luo, Guangnan; Wang, Dezhen

    2015-01-01

    Highlights: • We study the surface evolution of rough surface on divertor target in fusion devices. • The effects of gyration motion and E × B drift affect 3D angular distribution. • A larger magnetic field angle leads to a reduced net eroded areal density. • The rough surface evolution affects the physical sputtering yield. - Abstract: The 3D Monte-Carlo code SURO has been used to study the surface evolution of rough surface on the divertor target in fusion devices. The edge plasma at divertor region is modelled by the SDPIC code and used as input data for SURO. Coupled with SDPIC, SURO can perform more sophisticated simulations to calculate the local angle and surface evolution of rough surface. The simulation results show that the incident direction of magnetic field, gyration and E × B force has a significant impact on 3D angular distribution of background plasma and accordingly on the erosion of rough surface. The net eroded areal density of rough surface is studied by varying the magnetic field angle with surface normal. The evolution of the microscopic morphology of rough surface can lead to a significant change in the physical sputtering yield

  12. Optical fibre angle sensor used in MEMS

    International Nuclear Information System (INIS)

    Golebiowski, J; Milcarz, Sz; Rybak, M

    2014-01-01

    There is a need for displacement and angle measurements in many movable MEMS structures. The use of fibre optical sensors helps to measure micrometre displacements and small rotation angles. Advantages of this type of transducers are their simple design, high precision of processing, low costs and ability of a non-contact measurement. The study shows an analysis of a fibre-optic intensity sensor used for MEMS movable structure rotation angle measurement. An intensity of the light in the photodetector is basically dependent on a distance between a reflecting surface and a head surface of the fibre transmitting arm, and the deflection angle. Experimental tests were made for PMMA 980/1000 plastic fibres, Θ NA =33°. The study shows both analytical and practical results. It proves that calculated and experimental characteristics for the analysed transducers are similar.

  13. Low angle X-ray scattering

    International Nuclear Information System (INIS)

    Torrianni, I.L.

    1983-01-01

    The theoretical and experimental problems appearing in diffraction experiments at very low angles by several kinds of materials are discussed. The importance of synchrotron radiation in such problems is shown. (L.C.) [pt

  14. Directional Wide-Angle Range Finder (DWARF)

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation, the Directional Wide-Angle Range Finder (DWARF) is the creation of a laser range-finder with a wide field-of-view (FOV) and a directional...

  15. Angle measurement with laser feedback instrument.

    Science.gov (United States)

    Chen, Wenxue; Zhang, Shulian; Long, Xingwu

    2013-04-08

    An instrument for angle measurement based on laser feedback has been designed. The measurement technique is based on the principle that when a wave plate placed into a feedback cavity rotates, its phase retardation varies. Phase retardation is a function of the rotating angle of the wave plate. Hence, the angle can be converted to phase retardation. The phase retardation is measured at certain characteristic points identified in the laser outputting curve that are then modulated by laser feedback. The angle of a rotating object can be measured if it is connected to the wave plate. The main advantages of this instrument are: high resolution, compact, flexible, low cost, effective power, and fast response.

  16. Precision Guidance with Impact Angle Requirements

    National Research Council Canada - National Science Library

    Ford, Jason

    2001-01-01

    This paper examines a weapon system precision guidance problem in which the objective is to guide a weapon onto a non-manoeuvring target so that a particular desired angle of impact is achieved using...

  17. DEVICE FOR CONTROL OF OXYGEN PARTIAL PRESSURE

    Science.gov (United States)

    Bradner, H.; Gordon, H.S.

    1957-12-24

    A device is described that can sense changes in oxygen partial pressure and cause a corresponding mechanical displacement sufficient to actuate meters, valves and similar devices. A piston and cylinder arrangement contains a charge of crystalline metal chelate pellets which have the peculiar property of responding to variations in the oxygen content of the ambient atmosphere by undergoing a change in dimension. A lever system amplifies the relative displacement of the piston in the cylinder, and actuates the controlled valving device. This partial pressure oxygen sensing device is useful in controlled chemical reactions or in respiratory devices such as the oxygen demand meters for high altitude aircraft.

  18. A study on projection angles for an optimal image of PNS water's view on children

    International Nuclear Information System (INIS)

    Son, Sang Hyuk; Song, Young Geun; Kim, Sung Kyu; Hong, Sang Woo; Kim, Je Bong

    2007-01-01

    This study is to calculate the proper angle for the optimal image of PNS Water's view on children, comparing and analyzing the PNS Water's projection angles between children and adults at every age. This study randomly selected 50 patients who visited the Medical Center from January to May in 2005, and examined the incidence path of central ray, taking a PNS Water's and skull trans-Lat. view in Water's filming position while attaching a lead ball mark on the Orbit, EAM, and acanthion of the patient's skull. And then, we calculated the incidence angles (angle A) of the line connected from OML and the petrous ridge to the inferior margin of maxilla on general (random) patient's skull image, following the incidence path of central ray. Finally, we analyzed two pieces of the graphs at ages, developing out the patient's ideal images at PNS Water's filming position taken by a digital camera, and calculating the angle (angle B) between OML and IP(Image Plate). The angle between OML and IP is about 43 .deg. in 4-years-old children, which is higher than 37 .deg. as age increases the angle decreases, it goes to 37 .deg. around 30 years of age. That is similar result to maxillary growth period. We can get better quality of Water's image for children when taking the PNS Water's view if we change the projection angles, considering maxillary growth for patients in every age stage

  19. Axial vector mass spectrum and mixing angles

    International Nuclear Information System (INIS)

    Caffarelli, R.V.; Kang, K.

    1976-01-01

    Spectral sum rules of the axial-vector current and axial-vector current-pseudoscalar field are used to study the axial-vector mass spectrum and mixing angles, as well as the decay constants and mixing angles of the pseudoscalar mesons. In general, the result is quite persuasive for the existence of the Jsup(PC) = 1 ++ multiplet in which one has a canonical D-E mixing. (Auth.)

  20. Contact angle hysteresis on superhydrophobic stripes.

    Science.gov (United States)

    Dubov, Alexander L; Mourran, Ahmed; Möller, Martin; Vinogradova, Olga I

    2014-08-21

    We study experimentally and discuss quantitatively the contact angle hysteresis on striped superhydrophobic surfaces as a function of a solid fraction, ϕS. It is shown that the receding regime is determined by a longitudinal sliding motion of the deformed contact line. Despite an anisotropy of the texture the receding contact angle remains isotropic, i.e., is practically the same in the longitudinal and transverse directions. The cosine of the receding angle grows nonlinearly with ϕS. To interpret this we develop a theoretical model, which shows that the value of the receding angle depends both on weak defects at smooth solid areas and on the strong defects due to the elastic energy of the deformed contact line, which scales as ϕS(2)lnϕS. The advancing contact angle was found to be anisotropic, except in a dilute regime, and its value is shown to be determined by the rolling motion of the drop. The cosine of the longitudinal advancing angle depends linearly on ϕS, but a satisfactory fit to the data can only be provided if we generalize the Cassie equation to account for weak defects. The cosine of the transverse advancing angle is much smaller and is maximized at ϕS ≃ 0.5. An explanation of its value can be obtained if we invoke an additional energy due to strong defects in this direction, which is shown to be caused by the adhesion of the drop on solid sectors and is proportional to ϕS(2). Finally, the contact angle hysteresis is found to be quite large and generally anisotropic, but it becomes isotropic when ϕS ≤ 0.2.