WorldWideScience

Sample records for angioplasty balloon

  1. Cutting Balloon angioplasty for cardiac transplant vasculopathy.

    OpenAIRE

    Takano, Y.; Currier, JW; Yeatman, LA; Kobashigawa, JA; Rogers, AD; Cianfichi, LJ; Fishbein, MC; Tobis, JM

    2002-01-01

    We performed Cutting Balloon angioplasty on 20 lesions in 11 heart transplant recipients 7.5 +/- 3.8 years after transplantation. The mean percentage of diameter stenosis decreased from 88.3% +/- 13.8% to 19.6% +/- 13.7% after Cutting Balloon angioplasty without complication. Seven patients underwent follow-up angiography at 4.9 +/- 1.7 months in a total of 12 lesions, and all lesions showed restenosis with a mean diameter stenosis of 84.4% +/- 19.2%. Cutting Balloon angioplasty can be used t...

  2. Cutting balloon angioplasty for intrastent restenosis treatment

    Directory of Open Access Journals (Sweden)

    João Orávio de Freitas Jr

    1999-05-01

    Full Text Available We describe here two patients with angiographic diagnosis of intrastent restenosis and regional myocardial ischemia. One stent restenosis was located in a native coronary artery and the other in a vein graft. Both were treated with cutting balloon angioplasty (CBA, inflated at low pressures. Angiographic success was obtained and both patients were discharged in the day after the procedure. Cutting balloon angioplasty using low inflation pressures achieved important luminal gains, in these two cases of intrastent restenosis. Further studies are necessary before the effectiveness of this procedure can be precisely defined.

  3. AUTOPERFUSION BALLOON CATHETER FOR COMPLICATED CORONARY ANGIOPLASTY - A PROSPECTIVE-STUDY WITH RETROSPECTIVE CONTROLS

    NARCIS (Netherlands)

    DEMUINCK, ED; VANDIJK, RB; DENHEIJER, P; MEEDER, JG; LIE, KI

    1992-01-01

    Prolonged angioplasty balloon inflation with an autoperfusion balloon for failed conventional coronary angioplasty, was compared with emergency surgery for this condition. Restenosis was assessed 6 weeks after successful intervention with the autoperfusion balloon. Forty consecutive patients with pe

  4. Intravascular ultrasound imaging following balloon angioplasty.

    Science.gov (United States)

    Tobis, J M; Mahon, D J; Moriuchi, M; Honye, J; McRae, M

    1991-01-01

    Despite its long history and reliability, contrast angiography has several inherent limitations. Because it is a two-dimensional projection image of the lumen contour, the wall thickness cannot be measured and the plaque itself is not visualized. This results in an underestimation of the amount of atherosclerotic disease by angiography. An assessment of atherosclerosis could be improved by an imaging modality: (1) that has an inherent larger magnification than angiography and (2) that directly visualizes the plaque. Intravascular ultrasound fulfils these criteria. This presentation will provide evidence that intravascular ultrasound may prove complimentary or even superior to angiography as an imaging modality. Intravascular ultrasound demonstrates excellent representations of lumen and plaque morphology of in vitro specimens compared with histology. There is very close intraobserver and interobserver variability of measurements made from intravascular ultrasound images. Phantom studies of stenoses in a tube model demonstrate that angiography can misrepresent the severity of stenosis when the lumen contour is irregular and not a typical ellipse, whereas intravascular ultrasound reproduces the cross-sectional morphology more accurately since it images the artery from within. In vitro studies of the atherosclerotic plaque tissue characteristics compare closely with the echo representation of fibrosis, calcification, and lipid material. In addition, in vitro studies of balloon angioplasty demonstrate that intravascular ultrasound accurately represents the changes in the structure of artery segments following balloon dilatation. PMID:1833473

  5. A Rare and Serious Unforeseen Complication of Cutting Balloon Angioplasty

    Directory of Open Access Journals (Sweden)

    Praveen Vemula

    2014-01-01

    Full Text Available Cutting balloon angioplasty (CBA is one of the adept ways of treating “in-stent restenosis.” Various complications related to cutting balloon angioplasty have been reported including arterial rupture, delayed perforation and fracture of microsurgical blades. Here we report a very unusual and inadvertent extraction of a stent previously deployed in the ramus intermedius coronary branch by a cutting balloon catheter. This required repeat stenting of the same site for an underlying dissection. Even though stent extraction is a rare complication it can be serious due to dissection, perforation, and closure of the artery. Physicians performing coronary artery interventions would need to be aware of this rare and serious complication especially if any difficulty is encountered while withdrawing the cutting balloon. Therefore, after removal, cutting balloon should be examined thoroughly for possible stent dislodgment or extraction when used for “in-stent restenosis.”

  6. Three dimensional intravascular ultrasonic assessment of the local mechanism of restenosis after balloon angioplasty

    NARCIS (Netherlands)

    M.A. Costa (Marco); P.J. de Feyter (Pim); K. Kozuma (Ken); A.L. Gaster; M. Sabaté (Manel); I.P. Kay (Ian Patrick); J.M.R. Ligthart (Jürgen); P. Thayssen; M.J.B.M. van den Brand (Marcel); P.W.J.C. Serruys (Patrick); D.P. Foley (David); W.J. van der Giessen (Wim)

    2001-01-01

    textabstractOBJECTIVE: To assess the mechanism of restenosis after balloon angioplasty. DESIGN: Prospective study. PATIENTS: 13 patients treated with balloon angioplasty. INTERVENTIONS: 111 coronary subsegments (2 mm each) were analysed after balloon angioplasty and at a six month follow up using th

  7. Modeling plaque fissuring and dissection during balloon angioplasty intervention.

    Science.gov (United States)

    Gasser, T Christian; Holzapfel, Gerhard A

    2007-05-01

    Balloon angioplasty intervention is traumatic to arterial tissue. Fracture mechanisms such as plaque fissuring and/or dissection occur and constitute major contributions to the lumen enlargement. However, these types of mechanically-based traumatization of arterial tissue are also contributing factors to both acute procedural complications and chronic restenosis of the treatment site. We propose physical and finite element models, which are generally useable to trace fissuring and/or dissection in atherosclerotic plaques during balloon angioplasty interventions. The arterial wall is described as an anisotropic, heterogeneous, highly deformable, nearly incompressible body, whereas tissue failure is captured by a strong discontinuity kinematics and a novel cohesive zone model. The numerical implementation is based on the partition of unity finite element method and the interface element method. The later is used to link together meshes of the different tissue components. The balloon angioplasty-based failure mechanisms are numerically studied in 3D by means of an atherosclerotic-prone human external iliac artery, with a type V lesion. Image-based 3D geometry is generated and tissue-specific material properties are considered. Numerical results show that in a primary phase the plaque fissures at both shoulders of the fibrous cap and stops at the lamina elastica interna. In a secondary phase, local dissections between the intima and the media develop at the fibrous cap location with the smallest thickness. The predicted results indicate that plaque fissuring and dissection cause localized mechanical trauma, but prevent the main portion of the stenosis from high stress, and hence from continuous tissue damage.

  8. Treatment of benign ureteral stricture by double J stents using high-pressure balloon angioplasty

    Institute of Scientific and Technical Information of China (English)

    YU Hua-liang; YE Lin-yang; LIN Mao-hu; YANG Yu; MIAO Rui; HU Xiao-juan

    2011-01-01

    Background Balloon dilatation angioplasty is a minimally invasive surgery for treating benign ureteral stricture. The aim of this study was to investigate the effect of placing double J (D-J) stents using high-pressure balloon angioplasty in treating benign ureteral stricture.Methods A total of 42 patients (48 cases) with benign ureteral stricture (42 had benign ureteral stricture) were investigated by inserting dual D-J stents using high-pressure balloon angioplasty. The control group contained 50 patients (57 cases) employing the conventional balloon angioplasty with a single D-J stent inserted for comparison.Results The overall effective rate of the treated and control groups was 87.8% (36/41) and 62.7% (32/51), respectively (P <0.05).Conclusion This new approach produces a better curative effect than the conventional balloon angioplasty with a single D-J stent insertion in treating benign ureteral stricture.

  9. Parallel wire balloon angioplasty for undilatable venous stenosis in hemodialysis fistula

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Tae Beom; You, Jin Jong; Cho, Jae Min [Gyeongsang National University Hospital, Jinju (Korea, Republic of)] (and others)

    2007-05-15

    The purpose of this study was to assess the value of the parallel wire balloon angioplasty technique for treating dysfunctional hemdialysis fistula with rigid stenosis, and this type of lesion was resistant to conventional angioplasty. Between March 2002 and August 2003, we included 6 patients (mean age: 59, males: 2, females: 4) who were treated via parallel the wire balloon angioplasty technique and their hemodialysis fistula has stenoses that were resistant to conventional angioplasty. We performed conventional angioplasty in all patients, but we failed to achieve sufficient dilatation. In the cases of highly resistant stenosis, an additional 0.016 inch wire was inserted into the 7 F vascular sheath. During angioplasty, a 0.016 inch guide wire was inserted between the balloon and the stenosis and then it was pushed to and fro until the balloon indentation disappeared. After the procedure, we performed angiography to identify the residual stenosis and the procedure-related complications. The undilatable stenoses in 5 patients were successfully resolved without complications via the parallel wire angioplasty technique. In one patient, indentation of balloon was not resolved, but the residual stenosis was both minimal and hemodynamically insignificant. The parallel wire angioplasty technique seems to be a feasible and cost-effective method for treating a dysfunctional hemodialysis fistula with undilatable and rigid stenosis.

  10. Absence of Bacteria on Coronary Angioplasty Balloons from Unselected Patients

    DEFF Research Database (Denmark)

    Hansen, Gorm Mørk; Nilsson, Martin; Nielsen, Claus Henrik;

    2015-01-01

    Periodontitis is a chronic, bacterially-induced inflammatory disease of the tooth-supporting tissues, which may result in transient bacteremia and a systemic inflammatory response. Periodontitis is associated with coronary artery disease independently of established cardiovascular risk factors......, and translocation of bacteria from the oral cavity to the coronary arteries may play a role in the development of coronary artery disease. Very few studies have used angioplasty balloons for in vivo sampling from diseased coronary arteries, and with varying results. Therefore, the aim of this study was to assess...... patients with stable angina, unstable angina/non-ST elevation myocardial infarction, and ST-elevation myocardial infarction (n = 15 in each group) were collected and analyzed using a PCR assay with high sensitivity and specificity for 16S rRNA genes of the oral microbiome. Despite elimination of extraction...

  11. Prediction of Outcome after Femoropopliteal Balloon Angioplasty by Intervascular Ultrasound

    DEFF Research Database (Denmark)

    Schroeder, Torben Veith; Vogt, Katja; Just, S.;

    1997-01-01

    original, intravascular ultrasound, percutaneous transluminal angioplasty, peripheral arteries, plaquemorphology, prediction of outcome......original, intravascular ultrasound, percutaneous transluminal angioplasty, peripheral arteries, plaquemorphology, prediction of outcome...

  12. Cephalic arch stenosis in autogenous brachiocephalic hemodialysis fistulas: results of cutting balloon angioplasty

    DEFF Research Database (Denmark)

    Heerwagen, Søren Thorup; Lönn, Lars; Schroeder, Torben V;

    2010-01-01

    Cephalic arch stenosis is a known cause of hemodialysis access failure in patients with brachiocephalic fistulas (BCFs). Outcomes of endovascular treatment are affected by resistance of the stenosis to balloon dilation, a high vein rupture rate and the development of early restenosis. The purpose...... of this retrospective study was to report outcomes after cutting balloon angioplasty (CBA) of cephalic arch stenosis....

  13. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); P.P.T. de Jaegere (Peter); F. Kiemeneij (Ferdinand); C.M. Miguel (Carlos); W.R. Rutsch (Wolfgang); G.R. Heyndrickx (Guy); H.U. Emanuelsson (Hakan); J. Marco (Jean); V.M.G. Legrand (Victor); P.H. Materne (Phillipe); J.A. Belardi (Jorge); U. Sigwart (Ulrich); A. Colombo (Antonio); J-J. Goy (Jean-Jacques); P.A. van den Heuvel (Paul); J. Delcan; M-A.M. Morel (Marie-Angèle)

    1994-01-01

    textabstractBalloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical outcomes as c

  14. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease.

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); P.P.T. de Jaegere (Peter); F. Kiemeneij (Ferdinand); C.M. Miguel (Carlos); W.R. Rutsch (Wolfgang); G.R. Heyndrickx (Guy); H.U. Emanuelsson (Hakan); J. Marco (Jean); V.M.G. Legrand (Victor); P.H. Materne (Phillipe); J.A. Belardi (Jorge); U. Sigwart (Ulrich); A. Colombo (Antonio); J-J. Goy (Jean-Jacques); P. van den Heuvel; J. Delcan; M-A.M. Morel (Marie-Angèle)

    1994-01-01

    textabstractBACKGROUND. Balloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical o

  15. Comparison of a nitinol stent versus balloon angioplasty for treatment of a dysfunctional arteriovenous graft

    International Nuclear Information System (INIS)

    This study aimed to 1) evaluate the outcome of placing a nitinol stent for treating dysfunctional arteriovenous grafts (AVG), and 2) compare the results with those of successful balloon angioplasty. Between February 2008 and October 2011, we retrospectively reviewed the interventional data and medical records of 29 patients (21 men, 8 women; mean age, 67.4 years) who underwent interventional procedures for dysfunctional AVG. Stents were placed only in cases with inadequate angioplasty results. Stent patency was evaluated and compared to cases of successful balloon angioplasty using the Kaplan Meier analysis. Eleven stents and 18 angioplasties were performed successfully at the venous anastomotic site of AVG. The primary patency at 3, 6, 12, and 18 months did not differ significantly for stent placement and angioplasty (52%, 29%, 15%, 15% vs. 71%, 50%, 34%, 34%; mean survival, 164 vs. 253 days, p = 0.283). Secondary patency of the stent also did not differ significantly from angioplasty (80%, 80%, 49%, 49% vs. 76%, 57%, 57%, 36%; mean survival, 405 vs. 385 days, p = 0.553). Nitinol stent placement was effective for treating dysfunctional AVG, but did not improve the primary and secondary patency compared to successful angioplasty

  16. Comparison of a nitinol stent versus balloon angioplasty for treatment of a dysfunctional arteriovenous graft

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yeo Chang; Shin, Byung Seok; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dankook Univ. Hospital, Cheonan (Korea, Republic of); Ohm, Joon Young [The Catholic Univ. of Korea College of Medicine/Bucheon St. Mary' s Hospital, Bucheon (Korea, Republic of); Kim, Ho Jun [Konyang Univ. Hospital, Daejeon (Korea, Republic of)

    2012-06-15

    This study aimed to 1) evaluate the outcome of placing a nitinol stent for treating dysfunctional arteriovenous grafts (AVG), and 2) compare the results with those of successful balloon angioplasty. Between February 2008 and October 2011, we retrospectively reviewed the interventional data and medical records of 29 patients (21 men, 8 women; mean age, 67.4 years) who underwent interventional procedures for dysfunctional AVG. Stents were placed only in cases with inadequate angioplasty results. Stent patency was evaluated and compared to cases of successful balloon angioplasty using the Kaplan Meier analysis. Eleven stents and 18 angioplasties were performed successfully at the venous anastomotic site of AVG. The primary patency at 3, 6, 12, and 18 months did not differ significantly for stent placement and angioplasty (52%, 29%, 15%, 15% vs. 71%, 50%, 34%, 34%; mean survival, 164 vs. 253 days, p = 0.283). Secondary patency of the stent also did not differ significantly from angioplasty (80%, 80%, 49%, 49% vs. 76%, 57%, 57%, 36%; mean survival, 405 vs. 385 days, p = 0.553). Nitinol stent placement was effective for treating dysfunctional AVG, but did not improve the primary and secondary patency compared to successful angioplasty.

  17. Prediction of outcome after femoropopliteal balloon angioplasty by intravascular ultrasound

    DEFF Research Database (Denmark)

    Vogt, K C; Just, S; Rasmussen, John Bøje Grønvall;

    1997-01-01

    OBJECTIVE: To evaluate intravascular ultrasound (IVUS) as a control procedure after femoropopliteal percutaneous transluminal angioplasty (PTA), and compare it with arteriography. DESIGN: Descriptive study. MATERIAL: Arteriographic and intravascular ultrasound data obtained from 18 patients (20...

  18. Postpartum cerebral angiopathy: atypical features and treatment with intracranial balloon angioplasty

    International Nuclear Information System (INIS)

    Postpartum cerebral angiopathy (PCA) is an uncommon cause of ischemic and hemorrhagic stroke in young women. It is usually clinically benign and not relapsing. We describe a patient with non-hemorrhagic PCA who had an atypical progressive neurological deficit from bilateral hemisphere watershed ischemia despite treatment with aggressive medical therapy and intracranial balloon angioplasty. (orig.)

  19. Postpartum cerebral angiopathy: atypical features and treatment with intracranial balloon angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Song, J.K. [Center for Endovascular Surgery, Hyman-Newman Inst. for Neurology and Neurosurgery, New York, NY (United States); Cacayorin, E.D. [Interventional Neuroradiology, Dept. of Radiology, Univ. of Texas Medical School, Houston, TX (United States); Fisher, S.; Seifert, T.D.; Alexandrov, A.V.; Malkoff, M.D.; Grotta, J.C.; Campbell, M.S. [Div. of Stroke Neurology, Dept. of Neurology, Univ. of Texas Medical School, Houston, TX (United States)

    2004-12-01

    Postpartum cerebral angiopathy (PCA) is an uncommon cause of ischemic and hemorrhagic stroke in young women. It is usually clinically benign and not relapsing. We describe a patient with non-hemorrhagic PCA who had an atypical progressive neurological deficit from bilateral hemisphere watershed ischemia despite treatment with aggressive medical therapy and intracranial balloon angioplasty. (orig.)

  20. Wiktor stent implantation in patients with restenosis following balloon angioplasty of a native coronary artery

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); M.E. Bertrand (Michel); V. Wiegand; G. Kober; J.F. Marquis; B. Valeix; R. Uebis; J. Piessen; P.P.T. de Jaegere (Peter)

    1992-01-01

    textabstractIntracoronary stenting has been introduced as an adjunct to balloon angioplasty aimed at overcoming its limitations, namely acute vessel closure and late restenosis. This study reports the first experience with the Wiktor stent implanted in the first 50 consecutive patients. All patients

  1. Evaluation of interventional angioplasty by using thrombolysis and balloon dilatation in treating pulmonary embolism

    International Nuclear Information System (INIS)

    Objective: To evaluate the interventional angioplasty by using thrombolysis and balloon dilatation in the treatment of pulmonary embolism. Methods: Eight patients with pulmonary embolism were treated with interventional management including fragmentation of the thrombus, thrombolysis with urokinase flush infusion, balloon dilatation and continuing low-dose infusion for 24 hours. Anticoagulation with heparin was given simultaneously. Results: The pulmonary artery was completely recanalized in three patients, and partially recanalized in five patients. The blood oxygen saturation reached 100% in 3 cases and was over 93% in 5 cases. Conclusion: Interventional angioplasty by means of thrombolysis or balloon dilatation is an effective therapy for pulmonary embolism in reopening the embolized pulmonary artery, bringing the pulmonary hemodynamics to normal condition and correcting the hypoxemia. (authors)

  2. Cutting-Balloon Angioplasty Versus Balloon Angioplasty as Treatment for Short Atherosclerotic Lesions in the Superficial Femoral Artery: Randomized Controlled Trial

    Energy Technology Data Exchange (ETDEWEB)

    Poncyljusz, Wojciech, E-mail: wponcyl@poczta.onet.pl; Falkowski, Aleksander, E-mail: bakhis@hot.pl [Pomeranian Medical University, Department of Interventional Radiology (Poland); Safranow, Krzysztof, E-mail: chrissaf@mp.pl; Rac, Monika, E-mail: carmon@pum.edu.pl [Pomeranian Medical University, Department of Biochemistry and Medical Chemistry (Poland); Zawierucha, Dariusz, E-mail: dariusz13@yahoo.com [Interventional Radiology, Sacred Heart Medical Center, River Bend (United States)

    2013-12-15

    Purpose: To evaluate the treatments of a short-segment atherosclerotic stenosis in the superficial femoral arteries with the cutting balloon angioplasty (CBA) versus conventional balloon angioplasty [percutaneous transluminal angioplasty (PTA)] in a randomized controlled trial. Material and Methods: The study group comprised 60 patients (33 men, 27 women; average age 64 years) with a short ({<=}5 cm) focal SFA de novo atherosclerotic stenosis associated with a history of intermittent claudication or rest pain. The primary end point of this study was the rate of binary restenosis in the treated segment 12 months after the intervention. All patients were evenly randomized to either the PTA or CBA treatment arms. Follow-up angiograms and ankle-brachial index (ABI) measurements were performed after 12 months. The evaluation of the restenosis rates and factors influencing its occurrence were calculated by logistic regression analysis. Results: In the intention-to-treat analysis, restenosis rates after 2-month follow-up were 9 of 30 (30 %) in the PTA group and 4 of 30 (13 %) in the CBA group (p = 0.117). In the actual treatment analysis, after exclusion of patients who required nitinol stent placement for a suboptimal result after angioplasty alone (5 patients in the PTA group and none in the CBA group), restenosis rates were 9 of 25 (36 %) and 4 of 30 (13 %), respectively (p = 0.049). In the intention-to-treat analysis there were also significant differences in ABI values between the PTA and CBA groups at 0.77 {+-} 0.11 versus 0.82 {+-} 0.12, respectively (p = 0.039), at 12 months. Conclusion: Based on the presented results of the trial, CBA seems to be a safer and more effective than PTA for treatment of short atherosclerotic lesions in the superior femoral artery.

  3. Optical coherence tomography layer thickness characterization of a mock artery during angioplasty balloon deployment

    Science.gov (United States)

    Azarnoush, Hamed; Vergnole, Sébastien; Boulet, Benoît; Lamouche, Guy

    2011-03-01

    Optical coherence tomography (OCT) is used to study the deformation of a mock artery in an angioplasty simulation setup. An OCT probe integrated in a balloon catheter provides intraluminal real-time images during balloon inflation. Swept-source OCT is used for imaging. A 4 mm semi-compliant polyurethane balloon is used for experiments. The balloon is inflated inside a custom-built multi-layer artery phantom. The phantom has three layers to mock artery layers, namely, intima, media and adventitia. Semi-automatic segmentation of phantom layers is performed to provide a detailed assessment of the phantom deformation at various inflation pressures. Characterization of luminal diameter and thickness of different layers of the mock artery is provided for various inflation pressures.

  4. Ureteric angioplasty balloon placement to increase localised dosage of BCG for renal pelvis TCC.

    LENUS (Irish Health Repository)

    Forde, J C

    2012-03-01

    Endoscopic percutaneous resection of a renal pelvis transitional cell carcinoma (TCC) is a viable treatment option in those who would be rendered dialysis dependent following a nephroureterectomy. We report endoscopic percutaneous resection of an upper tract TCC recurrence in a single functioning kidney followed by antegrade renal pelvis BCG instillation with novel placement of inflated angioplasty balloon in the ureter to help localise its effect.

  5. Unusual Response of Subclavian In-Stent Restenosis to Balloon Angioplasty in a Patient with HIV

    Directory of Open Access Journals (Sweden)

    Mohammad Atif Rana

    2015-01-01

    Full Text Available Human Immunodeficiency Virus (HIV infection and use of protease inhibitors have been associated with accelerated atherosclerosis. Increased rates of coronary in-stent restenosis are reported in these patients. There is limited data available on peripheral vascular disease interventions on these patients. Herein we report an aggressive subclavian in-stent restenosis with an unexpected response to balloon angioplasty treatment with a large, mobile tissue flap formation and its treatment with another stent.

  6. Characterization of Pebax angioplasty balloon surfaces with AFM, SEM, TEM, and SAXS.

    Science.gov (United States)

    Warner, Jacob A; Forsyth, Bruce; Zhou, Fang; Myers, Jason; Frethem, Chris; Haugstad, Greg

    2016-04-01

    In the medical device industry, angioplasty balloons have been widely used in the less invasive treatment of heart disease by expanding and relieving clogged structures in various arterial segments. However, new applications using thin coatings on the balloon surface have been explored to enhance therapeutic value in the delivery of pharmaceuticals (drug-elution) or control thermal energy output (RF ablation). In this study, angioplasty balloon materials comprised of poly(ether-block-amide) (Pebax) were investigated via atomic force microscopy (AFM), transmission electron microscopy (TEM), scanning electron microscopy (SEM), and small-angle X-ray scattering (SAXS) to characterize physical properties at the balloon surface that may affect coating adhesion. The soft segment of this Pebax 1074 material is polyethylene oxide (PEO) and the hard segment is nylon-12. The morphology of the hard segments of this block co-polymer are found via AFM stiffness measurements to be (40 ± 20) nm by (300 ± 150) nm and are oriented parallel to the surface of the balloon. SAXS measurements found the lamellar spacing to be (18.5 ± 0.5) nm, and demonstrate a preferential orientation in agreement with TEM and AFM measurements. Fixation of this balloon in resin, followed by cryo-sectioning is shown to provide a novel manner in which to investigate surface characteristics on the balloon such as material or coating thickness as well as uniformity in comparison to the bulk structure. These outputs were deemed critical to improve overall balloon processing such as molding and surface treatment options for robust designs toward better procedural outcomes targeting new therapeutic areas. PMID:25891789

  7. Angioplasty and stent - heart - discharge

    Science.gov (United States)

    Drug-eluting stents - discharge; PCI - discharge; Percutaneous coronary intervention - discharge; Balloon angioplasty - discharge; Coronary angioplasty - discharge; Coronary artery angioplasty - discharge; Cardiac ...

  8. Infrapopliteal Percutaneous Transluminal Balloon Angioplasty: Clinical Results and Influence Factors

    Energy Technology Data Exchange (ETDEWEB)

    Song, Jang Hyeon; Lee, Seung Jin; Jung, Hye Doo; Lim, Jae Hoon; Chang, Nam Kyu; Yim, Nam Yeol; Kim, Jae Kyu [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Lee, Keun Bae [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2011-09-15

    To assess the efficacy of percutaneous transluminal angioplasty (PTA) in patients with infrapopliteal arterial disease, and to determine the influencing factor for prognosis. A total of 55 patients (60 limbs) with infrapopliteal arterial stenosis or occlusion underwent PTA. Atherosclerotic risk factors, clinical symptoms, TransAtlantic Inter-Society Consensus (TASC) classification, and vascular wall calcification were evaluated before PTA. The number of patent infrapopliteal arteries was estimated, and the outcome was evaluated by symptom relief and limb salvage. Technical success was achieved in 53/60 limbs (88.3%) and 81/93 arteries (87.1%), TASC classification (p = 0.038) and vascular calcification (p = 0.002) influenced on technical failure. During follow-up, 26 of 55 limbs (47%) achieved symptom relief and 42/55 limbs (76%) underwent limb salvage. Non-diabetic patients (9/12, 75%) were superior to diabetic patients (17/43, 40%) in terms of symptom relief (p = 0.024). TASC classification and vascular wall calcification influenced on symptom relief and limb salvage. The number of patent infrapopliteal arteries after PTA influenced symptom relief (p < 0.001) and limb amputation (p = 0.003). PTA in patients with chronic critical limb ischemia is worthwhile as a primary treatment. The influence factors should be considered before PTA, and PTA should be performed in as many involved arteries as possible.

  9. Balloon pulmonary angioplasty: a treatment option for inoperable patients with chronic thromboembolic pulmonary hypertension

    Directory of Open Access Journals (Sweden)

    Aiko eOgawa

    2015-02-01

    Full Text Available In chronic thromboembolic pulmonary hypertension, stenoses or obstructions of the pulmonary arteries due to organized thrombi can cause an elevation in pulmonary artery resistance, which in turn can result in pulmonary hypertension. Chronic thromboembolic pulmonary hypertension can be cured surgically by pulmonary endarterectomy; however, patients deemed unsuitable for pulmonary endarterectomy due to lesion, advanced age, or comorbidities have a poor prognosis and limited treatment options. Recently, advances have been made in balloon pulmonary angioplasty for these patients, and this review highlights this recent progress.

  10. Critical appraisal of paclitaxel balloon angioplasty for femoral–popliteal arterial disease

    Science.gov (United States)

    Herten, Monika; Torsello, Giovanni B; Schönefeld, Eva; Stahlhoff, Stefan

    2016-01-01

    Peripheral arterial disease, particularly critical limb ischemia, is an area with urgent need for optimized therapies because, to date, vascular interventions often have limited life spans. In spite of initial encouraging technical success after femoropopliteal percutaneous transluminal angioplasty or stenting, postprocedural restenosis remains the major problem. The challenging idea behind the drug-coated balloon (DCB) concept is the biological modification of the injury response after balloon dilatation. Antiproliferative drugs administered via DCBs or drug-eluting stents are able to suppress neointimal hyperplasia, the main cause of restenosis. This article reviews the results of DCB treatments of femoropopliteal and infrapopliteal lesions in comparison to standard angioplasty with uncoated balloons. A systematic literature search was performed in 1) medical journals (ie, MEDLINE), 2) international registers for clinical studies (ie, www.clinicaltrials.gov), and 3) abstracts of scientific sessions. Several controlled randomized trials with follow-up periods of up to 5 years demonstrated the efficacy of paclitaxel –DCB technology. However, calcified lesions seem to affect the efficacy of DCB. Combinations of preconditioning methods with DCBs showed promising results. Although the mechanical abrasion of calcium via atherectomy or laser ablation showed favorable periprocedural results, the long-term impact on restenosis and clinical outcome has to be demonstrated. Major advantages of the DCBs are the rapid delivery of drug at uniform concentrations with a single dose, their efficacy in areas wherein stents have been contraindicated until now (ie, bifurcation, ostial lesions), and in leaving no stent scaffold behind. Reinterventions are easier to perform because DCBs leave no metal behind. Various combinations of DCBs with other treatment modalities may prove to be viable options in future. The follow-up results of clinical studies will evaluate the long

  11. Intravascular ultrasound imaging of peripheral arteries as an adjunct to balloon angioplasty and atherectomy.

    Science.gov (United States)

    Korogi, Y; Hirai, T; Takahashi, M

    1996-01-01

    This article reviews many of the applications of intravascular ultrasound (US) imaging for peripheral arterial diseases. In vitro studies demonstrate an excellent correlation between ultrasound measurements of lumen and plaque cross-sectional area compared with histologic sections. In vivo clinical studies reveal the enhanced diagnostic capabilities of this technology compared with angiography. Intravascular US imaging can provide valuable information on the degree, eccentricity, and histologic type of stenosis before intervention, and on the morphological changes in the arterial wall and the extent of excision after intervention. Intravascular US may also serve as a superior index for gauging the diameter of balloon, stent, laser probe, and/or atherectomy catheter appropriate for a proposed intervention. Significant new insights into the mechanisms of balloon angioplasty and atherectomy have been established by intravascular US findings. Intravascular US imaging has been shown to be a more accurate method than angiography for determining the cross-sectional area of the arterial lumen, and for assessing severity of stenosis. Quantitative assessment of the luminal cross-sectional area after the balloon dilatation should be more accurate than angiography as intimal tears or dissections produced by the dilatation may not be accurately evaluated with angiography. At the present time, intravascular US is still a controversial imaging technique. Outcome studies are currently being organized to assess the clinical value and cost effectiveness of intravascular ultrasound in the context of these interventional procedures. PMID:8653738

  12. Angioplasty and stent placement - peripheral arteries - discharge

    Science.gov (United States)

    Percutaneous transluminal angioplasty - peripheral artery - discharge; PTA - peripheral artery - discharge; Angioplasty - peripheral artery - discharge; Balloon angioplasty - peripheral artery- discharge; PAD - PTA ...

  13. Preliminary experience with drug-coated balloon angioplasty in primary percutaneous coronary intervention

    Institute of Scientific and Technical Information of China (English)

    Hee; Hwa; Ho; Julian; Tan; Yau; Wei; Ooi; Kwok; Kong; Loh; Than; Htike; Aung; Nwe; Tun; Yin; Dasdo; Antonius; Sinaga; Fahim; Haider; Jafary; Paul; Jau; Lueng; Ong

    2015-01-01

    We evaluated the clinical feasibility of using drugcoated balloon(DCB) angioplasty in patients undergoingprimary percutaneous coronary intervention(PPCI). Between January 2010 to September 2014,89 STelevation myocardial infarction patients(83% male,mean age 59 ± 14 years) with a total of 89 coronary lesions were treated with DCB during PPCI. Clinical outcomes are reported at 30 d follow-up. Left anterior descending artery was the most common target vessel for PCI(37%). Twenty-eight percent of the patients had underlying diabetes mellitus. Mean left ventricular ejection fraction was 44% ± 11%. DCB-only PCI was the predominant approach(96%) with the remaining 4% of patients receiving bail-out stenting. Thrombolysis in Myocardial Infarction(TIMI) 3 flow was successfully restored in 98% of patients. An average of 1.2 ± 0.5 DCB were used per patient,with mean DCB diameter of 2.6 ± 0.5 mm and average length of 23.2 ± 10.2 mm. At 30-d follow-up,there were 4 deaths(4.5%). No patients experienced abrupt closure of the infarctrelated artery and there was no reported target-lesion failure. Our preliminary experience showed that DCB angioplasty in PPCI was feasible and associated with a high rate of TIMI 3 flow and low 30-d ischaemic event.

  14. Influence of inflation pressure and balloon size on the development of intimal hyperplasia after balloon angioplasty. A study in the atherosclerotic rabbit.

    Science.gov (United States)

    Sarembock, I J; LaVeau, P J; Sigal, S L; Timms, I; Sussman, J; Haudenschild, C; Ezekowitz, M D

    1989-10-01

    To evaluate the effect of balloon size and inflation pressure on acute and subsequent outcome following balloon angioplasty (BA), 70 New Zealand White rabbits with bilateral femoral atherosclerosis were assigned to four groups: group 1, oversized balloon, low inflation pressure (n = 35 vessels; balloon size, 3.0 mm/inflation pressure, 5 atm); group 2, oversized balloon, high inflation pressure (n = 36; 3.0 mm/10 atm); group 3, appropriate size, low inflation pressure (n = 17; 2.5 mm/5 atm); and group 4, appropriate size balloon, high inflation pressure (n = 19; 2.5 mm/10 atm). Angiograms were obtained before, 10 minutes after, and 28 days after BA and read by two blinded observers using electronic calipers. The in vivo balloon-to-vessel ratio was measured for each group. There were eight non-BA controls. Rabbits were sacrificed either immediately (n = 34) or at 28 days after BA (n = 36), with the femoral vessels pressure perfused for histologic and morphometric analysis. The latter was performed at 28 days only. Absolute angiographic diameters increased in all groups immediately after BA (p less than 0.01). Acute angiographic success, defined as greater than 20% increase in luminal diameter, was higher using high inflation pressure (group 2, 32/36 [89%] and group 4, 16/19 [84%] vs. group 1, 23/35 [66%] and group 3, 9/17 [53%]; p less than 0.05). A 3.0-mm balloon resulted in significant oversizing irrespective of inflation pressure (balloon-to-vessel ratio, 1.5 +/- 0.1 vs. 1.1 +/- 0.1 to 1, for the 2.5-mm balloon). Vessels exposed to high inflation pressure had a significantly higher incidence of mural thrombus, dissection (p less than 0.01), and medial necrosis versus low pressure (p less than 0.05). At 28 days, the rates of restenosis (defined as greater than 50% loss of initial gain) were 14/20 (70%), 11/16 (69%), 5/10 (50%), and 5/10 (50%) for groups 1 through 4 (p = NS; a trend in favor of the groups using an oversized balloon). There was an increase in the

  15. Deep sea water prevents balloon angioplasty-induced hyperplasia through MMP-2: an in vitro and in vivo study.

    Directory of Open Access Journals (Sweden)

    Pei-Chuan Li

    Full Text Available Major facts about the development of restenosis include vascular smooth muscle cells (VSMCs proliferation and migration. A previous study showed that in vitro treatment with magnesium chloride has the potential to affect the proliferation and migration of VSMCs. Magnesium is the major element in deep sea water (DSW and is a biologically active mineral. It is unclear whether DSW intake can prevent abnormal proliferation and migration of VSMCs as well as balloon angioplasty-induced neointimal hyperplasia. Thus, we attempted to evaluate the anti-restenotic effects of DSW and its possible molecular mechanisms. Several concentrations of DSW, based on the dietary recommendations (RDA for magnesium, were applied to a model of balloon angioplasty in SD rats. The results showed that DSW intake markedly increased magnesium content within the vascular wall and reduced the development of neointimal hyperplasia. The immunohistochemical analysis also showed that the expression of proteins associated with cell proliferation and migration were decreased in the balloon angioplasty groups with DSW supplement. Furthermore, in vitro treatment with DSW has a dose-dependent inhibitory effect on serum-stimulated proliferation and migration of VSMCs, whose effects might be mediated by modulation of mitogen-activated protein kinase (MAPK signaling and of the activity of matrix metalloproteinase-2 (MMP-2. Our study suggested that DSW intake can help prevent neointimal hyperplasia (or restenosis, whose effects may be partially regulated by magnesium and other minerals.

  16. Randomized Trial of the SMART Stent versus Balloon Angioplasty in Long Superficial Femoral Artery Lesions: The SUPER Study

    Energy Technology Data Exchange (ETDEWEB)

    Chalmers, Nicholas, E-mail: nicholas.chalmers@cmft.nhs.uk [Manchester Royal Infirmary, Department of Radiology (United Kingdom); Walker, Paul T. [James Cook University Hospital, Department of Radiology (United Kingdom); Belli, Anna-Maria [St. George' s Healthcare NHS Trust, Department of Radiology (United Kingdom); Thorpe, Anthony P. [Aberdeen Royal Infirmary, Department of Radiology (United Kingdom); Sidhu, Paul S. [King' s College Hospital, Department of Radiology (United Kingdom); Robinson, Graham [Hull Royal Infirmary, Department of Radiology (United Kingdom); Ransbeeck, Mariella van [Johnson and Johnson Medical NV/SA, Cordis (Belgium); Fearn, Steven A. [Johnson and Johnson Medical Ltd., Cordis (United Kingdom)

    2013-04-15

    To determine whether primary stenting reduces the rate of restenosis compared with balloon angioplasty alone in the endovascular treatment of long superficial femoral artery lesions; and to assess the effect of treatment on quality of life. A total of 150 patients with superior femoral artery occlusion or severe stenosis of 5-22 cm length from 17 UK centers were randomized to either primary stenting with the SMART stent or balloon angioplasty (i.e., percutaneous transluminal angioplasty, PTA). Bailout stent placement was permitted in case of inadequate result from PTA. The primary end point was restenosis measured by duplex ultrasound at 1 year. Quality-of-life assessments were performed by the EuroQol (EQ)-5D questionnaire. Mean lesion length was 123.0 mm in the stent group and 116.8 mm in the PTA group. A total of 140 (93.3 %) of 150 had total occlusions. At 12 months' follow-up, restenosis measured by Duplex ultrasound was not significantly different between the stent and PTA groups by intention-to-treat or as-treated analyses: 47.2 versus 43.5 % (p = 0.84) and 40.8 versus 46.7 % (p = 0.68), respectively. There were fewer target lesion revascularizations in patients randomized to stenting, but this did not reach statistical significance (12.5 vs. 20.8 %, p = 0.26). There was no difference in the rate of amputation. Patients in both groups reported improved quality of life. Primary stenting of long lesions in predominantly occluded superficial femoral arteries does not reduce the rate of binary restenosis compared with balloon angioplasty and bailout stenting. Both treatment strategies conferred a meaningful and sustained improvement to the quality of life of patients with severe superficial femoral artery disease.

  17. Changes in Right Ventricular Dysfunction After Balloon Pulmonary Angioplasty in Patients With Chronic Thromboembolic Pulmonary Hypertension.

    Science.gov (United States)

    Tsugu, Toshimitsu; Murata, Mitsushige; Kawakami, Takashi; Minakata, Yugo; Kanazawa, Hideaki; Kataoka, Masaharu; Endoh, Jin; Tsuruta, Hikaru; Itabashi, Yuji; Maekawa, Yuichiro; Abe, Takayuki; Fukuda, Keiichi

    2016-10-01

    The aim was to investigate the effect of balloon pulmonary angioplasty (BPA) on right ventricular (RV) function in chronic thromboembolic pulmonary hypertension. Twenty-six patients with chronic thromboembolic pulmonary hypertension were enrolled and were divided into 2 groups, group H with high (>30 mm Hg) mean pulmonary arterial pressure and group L with low (25 to 30 mm Hg) mean pulmonary arterial pressure. RV function was assessed using 2-dimensional speckle-tracking echocardiography as well as 3-dimensional echocardiography, and RV dyssynchrony was assessed by the RV strain curves. Exercise capacity was evaluated by the 6-minute walk distance. RV dilatation was significantly reduced after BPA. In group H, RV ejection fraction, RV free wall longitudinal strain and RV dyssynchrony were all impaired before BPA and were ameliorated after BPA. In group L, RV ejection fraction as well as RV dyssynchrony were impaired without the reduction of RV free wall longitudinal strain and were improved after BPA, indicating that RV dysfunction may be attributable to the RV dyssynchrony in group L. Furthermore, RV dyssynchrony at baseline was the only parameter that was correlated with improvement in the 6-minute walk distance after BPA. RV dyssynchrony may affect RV function and could be the useful parameter for clinical outcome after BPA. PMID:27530827

  18. Efficacy of cardiac rehabilitation after balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension

    Science.gov (United States)

    Fukui, Shigefumi; Ogo, Takeshi; Takaki, Hiroshi; Ueda, Jin; Tsuji, Akihiro; Morita, Yoshiaki; Kumasaka, Reon; Arakawa, Tetsuo; Nakanishi, Michio; Fukuda, Tetsuya; Yasuda, Satoshi; Ogawa, Hisao; Nakanishi, Norifumi; Goto, Yoichi

    2016-01-01

    Objective To determine safety and efficacy of cardiac rehabilitation (CR) initiated immediately following balloon pulmonary angioplasty (BPA) in patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH) who presented with continuing exercise intolerance and symptoms on effort even after a course of BPA; 2–8 sessions/patient. Methods Forty-one consecutive patients with inoperable CTEPH who underwent their final BPA with improved resting mean pulmonary arterial pressure of 24.7±5.5 mm Hg and who suffered remaining exercise intolerance were prospectively studied. Participants were divided into two groups just after the final BPA (6.8±2.3 days): patients with (CR group, n=17) or without (non-CR group, n=24) participation in a 12-week CR of 1-week inhospital training followed by an 11-week outpatient programme. Cardiopulmonary exercise testing, haemodynamics, and quality of life (QOL) were assessed before and after CR. Results No significant between-group differences were found for any baseline characteristics. At week 12, peak oxygen uptake (VO2), per cent predicted peak VO2 (70.7±9.4% to 78.2±12.8%, pBPA and subsequent CR is a new treatment strategy for inoperable CTEPH to improve exercise capacity to near-normal levels and HF symptoms, with a good safety profile. PMID:27220694

  19. Finite Element Modeling of Balloon Angioplasty by Considering Overstretch of Remnant Non-diseased Tissues in Lesions

    Science.gov (United States)

    Gasser, T. Christian; Holzapfel, Gerhard A.

    2007-06-01

    The paper deals with the modeling of balloon angioplasty by considering the balloon-induced overstretch of remnant non-diseased tissues in atherosclerotic arteries. A stenotic artery is modeled as a heterogenous structure composed of adventitia, media and a model plaque, and residual stresses are considered. The constitutive models are able to capture the anisotropic elastic tissue response in addition to the inelastic phenomena associated with tissue stretches beyond the physiological domain. The inelastic model describes the experimentally-observed changes of the wall during balloon inflation, i.e. non-recoverable deformation, and tissue weakening. The contact of the artery with a balloon catheter is simulated by a point-to-surface strategy. The states of deformations and stresses within the artery before, during and after balloon inflation are computed, compared and discussed. The 3D stress states at physiological loading conditions before and after balloon inflation differ significantly, and even compressive normal stresses may occur in the media after dilation.

  20. Effect and outcome of balloon angioplasty and stenting of the iliac arteries evaluated by intravascular ultrasound

    DEFF Research Database (Denmark)

    Vogt, K J; Rasmussen, John Bøje Grønvall; Just, S;

    1999-01-01

    To document the mechanism of percutaneous transluminal angioplasty (PTA) and stenting of the iliac arteries, and to relate the effect to patency.......To document the mechanism of percutaneous transluminal angioplasty (PTA) and stenting of the iliac arteries, and to relate the effect to patency....

  1. Prolonged high-pressure balloon angioplasty of femoropopliteal lesions:Impact on stent implantation rate and mid-term outcome

    Institute of Scientific and Technical Information of China (English)

    Gianluca Rigatelli; Mariano Palena; Paolo Cardaioli; Fabio dellAvvocata; Massimo Giordan; Dobrin Vassilev; Marco Manzi

    2014-01-01

    Objectives To assess the impact on stent implantation rate and mid-term outcomes of prolonged high pressure angioplasty of femoropopliteal lesions. Methods We retrospectively enrolled 620 consecutive patients from January 2011 to December 2011 (75.6 ±12.3 years, 355 males, 76.5%in Rutherford class 5-6), referred for critical limb ischemia and submitted to prolonged high-pressure angioplasty of femoropopliteal lesions. The definition of prolonged high-pressure angioplasty includes dilation to at least 18 atm for at least 120 s. Proce-dural data, and clinical and instrumental follow-up were analyzed to assess stent implantation rate and mid-term outcomes. Results The preferred approach was ipsilateral femoral antegrade in 433/620 patients (69.7%) and contralateral cross-over in 164/620 (26.4%) and pop-liteal retrograde+femoral antegrade in 23/620 (3.7%). Techniques included subintimal angioplasty in 427/620 patients (68.8%) and endolu-minal angioplasty in 193/620 patients (31.2%). The prolonged high pressure balloon angioplasty procedure was successful in 86.2%(minor intra-procedural complications rate 15.7%), stent implantation was performed in 74 patients (11.9%), with a significant improvement of ankle-brachial index (0.29 ±0.6 vs. 0.88 ±0.3, P<00.1) and Rutherford class (5.3 ±0.8 vs. 0.7 ±1.9, P<0.01), a primary patency rate of 86.7%, restenosis of 18.6%on Doppler ultrasound and a target lesion revascularization of 14.8%at a mean follow-up of 18.1 ±6.4 months (range 1-24 months). Secondary patency rate was 87.7%. Conclusions Prolonged high pressure angioplasty of femoropopliteal lesions appears to be safe and effective allowing for an acceptable patency and restenosis rates on mid-term.

  2. Optical coherence tomography monitoring of angioplasty balloon inflation in a deployment tester

    Science.gov (United States)

    Azarnoush, Hamed; Vergnole, Sébastien; Bourezak, Rafik; Boulet, Benoit; Lamouche, Guy

    2010-08-01

    We present an innovative integration of an intravascular optical coherence tomography probe into a computerized balloon deployment system to monitor the balloon inflation process. The high-resolution intraluminal imaging of the balloon provides a detailed assessment of the balloon quality and, consequently, a technique to improve the balloon manufacturing process. A custom-built swept-source optical coherence tomography system is used for real-time imaging. A semicompliant balloon with a nominal diameter of 4 mm is fabricated for the experiments. Imaging results correspond to balloon deployment in air and inside an artery phantom. A characterization of the balloon diameter, wall thickness, compliance, and elastic modulus is provided, based on image segmentation. Using the images obtained from the probe pullback, a three-dimensional visualization of the inflated balloon is presented.

  3. Lumen narrowing after percutaneous transluminal coronary balloon angioplasty follows a near gaussian distribution: a quantitative angiographic study in 1,445 successfully dilated lesions

    NARCIS (Netherlands)

    B.J.W.M. Rensing (Benno); W.R.M. Hermans (Walter); P.J. de Feyter (Pim); J.G.P. Tijssen (Jan); P.W.J.C. Serruys (Patrick); J.W. Deckers (Jaap)

    1992-01-01

    textabstractTo determine whether significant angiographic narrowing and restenosis after successful coronary balloon angioplasty is a specific disease entity occurring in a subset of dilated lesions or whether it is the tail end of a gaussian distributed phenomenon, 1,445 successfully dilated lesion

  4. Absence of Bacteria on Coronary Angioplasty Balloons from Unselected Patients: Results with Use of a High Sensitivity Polymerase Chain Reaction Assay.

    Science.gov (United States)

    Hansen, Gorm Mørk; Nilsson, Martin; Nielsen, Claus Henrik; Holmstrup, Palle; Helqvist, Steffen; Tolker-Nielsen, Tim; Givskov, Michael; Hansen, Peter Riis

    2015-01-01

    Periodontitis is a chronic, bacterially-induced inflammatory disease of the tooth-supporting tissues, which may result in transient bacteremia and a systemic inflammatory response. Periodontitis is associated with coronary artery disease independently of established cardiovascular risk factors, and translocation of bacteria from the oral cavity to the coronary arteries may play a role in the development of coronary artery disease. Very few studies have used angioplasty balloons for in vivo sampling from diseased coronary arteries, and with varying results. Therefore, the aim of this study was to assess if bacterial DNA from primarily oral bacteria could be detected on coronary angioplasty balloons by use of an optimized sampling process combined with an internally validated sensitive polymerase chain reaction (PCR) assay. Coronary angioplasty balloons and control samples from a total of 45 unselected patients with stable angina, unstable angina/non-ST elevation myocardial infarction, and ST-elevation myocardial infarction (n = 15 in each group) were collected and analyzed using a PCR assay with high sensitivity and specificity for 16S rRNA genes of the oral microbiome. Despite elimination of extraction and purification steps, and demonstration of sensitivity levels of 25-125 colony forming units (CFU), we did not detect bacterial DNA from any of the coronary angioplasty balloons. A subsequent questionnaire indicated that the prevalence of periodontitis in the study cohort was at least 39.5%. Although coronary angioplasty balloons are unlikely to be useful for detection of bacteria with current PCR techniques in unselected patients with coronary artery disease, more studies are warranted to determine the extent to which bacteria contribute to atherosclerosis and its clinical manifestations and whether the presence of bacteria in the arteries is a transient phenomenon.

  5. Ultrasonography-guided Balloon Angioplasty in an Autogenous Arteriovenous Fistula: Preliminary Results

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Chang [Daejeon St Mary' s Hospital, Daejeon (Korea, Republic of); Cho, June Sik [Chungnam National University College of Medicine, Daejeon (Korea, Republic of)

    2007-09-15

    Percutaneous trasnluminal angioplasty (PTA) of a malfunctioning arteriovenous fistula (AVF) in hemodialysis patients requires the use of contrast angiography and fluoroscopy guidance. We attempted to perform this procedure under duplex ultrasound guidance to reduce the amount of contrast agent administered and to reduce the radiation dose during the interventional procedures. From September 2006 to February 2007, 45 patients received interventional treatment due to malfunctioning hemodialysis access in our hospital. Among the patients, we selected 10 patients diagnosed with stenosis of an autogenous arteriovenous fistula based on a physical examination. There were six males and four females aged 51-78 years (mean age, 59 years). Seven of these patients had a Brescia-Cinimo type fistula and three patients had a basilic vein transposition. All procedures were performed in the angiography suite. All procedures that required angioplasty were performed under duplex ultrasound guidance and then contrast angiography was performed to confirm the final patency of the vessels. Conventional angioplasty was also performed under fluoroscopy guidance for any lesions that required an additional angioplasty. The volume flow before and after the PTA and procedure time were recorded. Clinical success was defined as the performance of one or more successful hemodialysis sessions after treatment. Eight of ten patients did not require an additional angioplasty by conventional angiography after the duplex- guided angioplasty. One case showed recoiling of stenosis after the duplex-guided PTA and another case was missed at duplex scanning due to the extremely short nature of the recoiling of stenosis. The mean volume flow before and after PTA was 167 ml/min (range, 80-259 ml/min) and 394.2 ml/min (range, 120-586 ml/min), respectively. No complications associated with the duplex-guide procedure occurred. In nine cases, PTA enabled hemodialysis to be conducted more than one time. In one

  6. Balloon angioplasty of popliteal and crural arteries in elderly with critical chronic limb ischemia

    International Nuclear Information System (INIS)

    Objective: Elderly patients with extensive infrainguinal peripheral vascular disease and critical chronic limb ischemia (CCLI) are poor surgical candidates. Our purpose was to evaluate angiographic and clinical results of popliteal, infrapopliteal, and multi-level disease percutaneous transluminal angioplasty (PTA) in such patients. Design: Retrospective study of angiographic and clinical files in selected group. Materials and methods: Between 1996 and 2002, 38 elderly patients aged 80-94 years old (mean age 83.3) with critical leg ischemia were treated with PTA. All patients were at high surgical risk. 31/38 (81.5%) patients had chronic non-healing wounds, and 14/38 (37%) had multi-level disease of superficial femoral, popliteal and crural arteries. One hundred and two lesions were treated by angioplasty. Immediate angiographic and 1 year clinical results were retrospectively analyzed. Results: The overall procedural success rate was 32/38 (84.2%). There were three major complications (7.9%), but no deaths, and three technical failures, all were of infrapopliteal lesions. After 1 year, 27 patients could be followed, five patients died during the first year of unrelated causes. Twenty-three patients (85.2%), were clinically re-occluded within 1 year, but complete and partial wound healing was achieved in 80% (16/20) and rest pain improvement in 57% (4/7), so that overall limb salvage was 74% (20/27). Conclusions: Elderly patients with multi-level CCLI have a short patency term following angioplasty of 14.8% after 1 year. Nevertheless, this temporary vascular patency enables wound healing or improvement in 74% of these patients, thus such endovascular interventions are recommended in this age group

  7. Percutaneous transluminal angioplasty and stenting of the vertebral artery ostium with balloon-mounted bare coronary stents

    Directory of Open Access Journals (Sweden)

    Javad Kojuri

    2011-01-01

    Full Text Available Background : Vertebral artery ostial stenosis (VAOS is one of the most frequent causes of posterior circulation stroke. Percutaneous angioplasty and stenting (PTAS is one of the treatment modalities. Patients and Methods : This is a longitudinal observational study from September 2006 to February 2009, conducted at hospitals affiliated with the Shiraz University of Medical Sciences, Shiraz, southern Iran. The patient cohort included patients with posterior circulation stroke or transient ischemic attack (TIA and more than 70% VAOS, and patients with asymptomatic VAOS of more than 70% and aplasia or total occlusion of the contralateral VA or subclavian artery. All the patients underwent PTAS with balloon-mounted bare coronary stents. Technical success, procedural complications, composite outcomes of death, stroke or TIA in the vertebrobasilar territory during the first 30 days, stroke or TIA in the vertebrobasilar territory, and restenosis during follow-up, were assessed. Results : During the study period, 81 patients (mean age 68 + 8.9 years, 63 (78% males, 71 symptomatic and 18 asymptomatic underwent the procedure. Technical success was achieved in 88 (99% patients. Procedure-related complications, other than puncture site complications, were seen in two patients (2.2%. The composite outcome of death, stroke or TIA in the vertebrobasilar territory during the first 30 days was 1%. None of the patients had clinical recurrence or restenosis during the follow-up (mean follow-up 14 months. Conclusion : Percutaneous transluminal angioplasty and stenting of the proximal VA was feasible and safe. The risk of restenosis should be analyzed in long-term studies with angiographic follow-up.

  8. Observation and nursing of complications due to high re-perfusion injury occurring after balloon angioplasty for diabetic vascular diseases of lower extremity

    International Nuclear Information System (INIS)

    Objective: To evaluate the symptomatic nursing in treating the complications caused by high re-perfusion which develops after balloon angioplasty for the treatment of diabetic vascular diseases of lower extremity. Methods: Eighteen patients with lower limb ischemia caused by diabetes mellitus developed high re-perfusion injury complications after receiving balloon angioplasty. The patients were randomly and equally divided into study group and control group. The special nursing measures designed by the author's department, including raising the diseased lower limb, enforcing the flexion and extension movement of the leg, cold compress, wound exposure, etc. were carried out for patients of study group, while no special nursing measures were adopted for patients of control group. The clinical results, such as limb pain, swelling and subcutaneous petechia after re-perfusion injury, were evaluated and compared between two groups. Results: After the treatment, the limb pain, swelling and subcutaneous petechia due to high re-perfusion injury in study group were relieved more markedly than that in control group, the difference in evaluation score between two groups was statistically significant (P<0.01). Conclusion: The special symptomatic nursing measures are very effective in relieving the high re-perfusion injury after balloon angioplasty for the treatment of diabetic lower limb ischemia. (authors)

  9. Cephalic arch stenosis in autogenous brachiocephalic hemodialysis fistulas: results of cutting balloon angioplasty

    DEFF Research Database (Denmark)

    Heerwagen, Søren Thorup; Lönn, Lars; Schroeder, Torben V;

    2010-01-01

    Cephalic arch stenosis is a known cause of hemodialysis access failure in patients with brachiocephalic fistulas (BCFs). Outcomes of endovascular treatment are affected by resistance of the stenosis to balloon dilation, a high vein rupture rate and the development of early restenosis. The purpose...

  10. Preparation and characterisation of polyamide 11/montmorillonite (MMT) nanocomposites for use in angioplasty balloon applications

    Energy Technology Data Exchange (ETDEWEB)

    Halim, Khairul Anwar A. [Department of Polymer Engineering, Athlone Institute of Technology, Athlone (Ireland); School of Materials Engineering, Universiti Malaysia Perlis, Perlis (Malaysia); Farrell, Joseph B. [Department of Polymer Engineering, Athlone Institute of Technology, Athlone (Ireland); Kennedy, James E., E-mail: jkennedy@ait.ie [Department of Polymer Engineering, Athlone Institute of Technology, Athlone (Ireland)

    2013-12-16

    With increased demands on catheter balloon functionality, there is an emphasis to blend new materials which can improve mechanical performance. Polymer nanocomposites were prepared by melt blending polyamide 11 (PA 11) with organically modified montmorillonite nanoclay. The effects of incorporating the nanoclay on the short-term mechanical properties of PA 11 were assessed using a design of experiments (DoEs) approach. X-ray diffraction (XRD), transmission electron microscopy (TEM), differential scanning calorimetry (DSC) and dynamic mechanical thermal analysis techniques (DMA) were used to characterise the morphology of the nanocomposites. Design of experiments studies revealed that the optimum nanocomposites properties can be achieved by carefully controlling the melt compounding parameters. XRD and TEM data proved that exfoliated clay morphologies existed within the matrix at low clay loading (2%). Whereas the interaction between the polymer matrix and nanoclay was quantified in the DMA spectra, showed a significant increase in storage modulus (up to 80%). The reinforcing effect of nanoclay within the PA 11 was further investigated using mechanical testing, where significant increases in the ultimate tensile strength and strain at break of reinforced tri-layer balloon tubing were observed. - Highlights: • TEM reveals the coexistence of exfoliated and intercalated nanostructures. • Isothermal crystallisation studies found that the nano-clays reduced the crystallisation time. • Significant increase in the storage modulus was due to the reinforcing effect of the nano-clay platelets. • It was observed that the activation energy values decreased due to the presence of nanoclay.

  11. Utility of birefringence changes due to collagen thermal denaturation rate process analysis: vessel wall temperature estimation for new short term heating balloon angioplasty

    Science.gov (United States)

    Kaneko, Kenji; Shimazaki, Natsumi; Gotoh, Maya; Nakatani, Eriko; Arai, Tsunenori

    2007-02-01

    Our photo thermal reaction heating architecture balloon realizes less than 10 s short term heating that can soften vessel wall collagen without damaging surrounding tissue thermally. New thermal balloon angioplasty, photo-thermo dynamic balloon angioplasty (PTDBA) has experimentally shown sufficient opening with 2 atm low pressure dilation and prevention of chronic phase restenosis and acute phase thrombus in vivo. Even though PTDBA has high therapeutic potential, the most efficient heating condition is still under study, because relationship of treatment and thermal dose to vessel wall is not clarified yet. To study and set the most efficient heating condition, we have been working on establishment of temperature history estimation method from our previous experimental results. Heating target of PTDBA, collagen, thermally denatures following rate process. Denaturation is able to be quantified with measured collagen birefringence value. To express the denaturation with equation of rate process, the following ex vivo experiments were performed. Porcine extracted carotid artery was soaked in two different temperature saline baths to enforce constant temperature heating. Higher temperature bath was set to 40 to 80 degree Celsius and soaking duration was 5 to 40 s. Samples were observed by a polarizing microscope and a scanning electron microscope. The birefringence was measured by polarizing microscopic system using Brace-Koehler compensator 1/30 wavelength. The measured birefringence showed temperature dependency and quite fit with the rate process equation. We think vessel wall temperature is able to be estimated using the birefringence changes due to thermal denaturation.

  12. Safety and efficacy of limus-eluting stents and balloon angioplasty for sirolimus-eluting in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideaki [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Mahmoudi, Michael [University of Surrey, Guildford Road, Surrey, GU2-7XH (United Kingdom); Kitabata, Hironori; Torguson, Rebecca; Chen, Fang; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D. [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Waksman, Ron, E-mail: ron.waksman@medstar.net [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States)

    2015-03-15

    Objectives: The aim of this study was to compare the safety and efficacy of everolimus-eluting stent (EES), sirolimus-eluting stent (SES), and plain old balloon angioplasty (POBA) for the treatment of SES in-stent restenosis (S-ISR). Background: The optimal treatment for drug-eluting in-stent restenosis remains controversial. Methods: The study cohort comprised 310 consecutive patients (444 lesions) who presented with S-ISR to our institution and underwent treatment with EES (43 patients), SES (102), or POBA (165). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac event (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors for coronary artery disease except for smoking. The 1-year analyzed clinical parameters were similar in the three groups: MACE (EES = 14%, SES = 18%, POBA = 20%; p = 0.65), death (EES = 2.3%, SES = 6.2%, POBA = 6.1%; p = 0.61), MI (EES = 4.8%, SES = 2.1%, POBA = 2.5%; p = 0.69), TLR (EES = 11.9%, SES = 12.1%, POBA = 24%; p = 0.78), and TVR (EES = 11.9%, SES = 24.8%, POBA = 22.2%; p = 0.23). There were no cases of definite ST. MACE-free rate was significantly lower in patients with recurrent in-stent restenosis (log-rank p = 0.006). Presentation with acute MI, number of treated lesions and a previous history of MI were found to be independent predictors of MACE. Conclusions: In patients presenting with S-ISR, treatment with implantation of an EES, SES, or POBA is associated with similar clinical outcomes. Patients presenting with recurrent ISR may have a poorer clinical outcome.

  13. Monitoring of gadolinium-BOPTA uptake into the vessel wall during magnetic resonance (MR)-guided angioplasty of the peripheral arteries with a paclitaxel/gadolinium-BOPTA-coated balloon. An experimental study at 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Neizel, M.; Kelm, M. [University Hospital Duesseldorf (Germany). Dept. of Cardiology, Pneumology and Angiology; Ruebben, A.; Weiss, N. [Aachen Resonance, Aachen (Germany); Guenther, R.W. [University Hospital Aachen (Germany). Dept. of Radiology; Krombach, G.A. [University Hospital Giessen (Germany). Dept. of Radiology

    2014-04-15

    Purpose: The success of paclitaxel distribution within the vessel wall during paclitaxel-coated balloon angioplasty to prevent restenosis cannot be monitored under X-ray guidance. The aim of this pilot study was to demonstrate the feasibility of monitoring Gadolinium-BOPTA delivery within the vessel wall during magnetic resonance (MR)-guided paclitaxel/Gadolinium-BOPTA-coated balloon angioplasty of the peripheral arteries. Materials and methods: 6 pigs (47 ± 2 kg) were investigated. All experiments were performed using a 3 Tesla MR scanner. MR-guided bilaterial angioplasty of the iliac arteries was performed using a paclitaxel/MR contrast agent-coated balloon catheter. The feasibility of monitoring the delivery of Gadolinium-BOPTA to the vessel was assessed in 4 animals. In two additional animals, bilateral stenosis was surgically induced in the iliac arteries. Delivery of paclitaxel to the vessel wall was monitored using a 3 D T1-weighted gradient echo (GE) sequence for delineation of the vessel wall. Normalized signal intensity (SI) of the vessel wall was measured before and repeatedly after the intervention for 45 min. in all animals. Results: Paclitaxel/gadolinium-BOPTA-coated balloon angioplasty was successfully accomplished in all iliac arteries (n = 12). In animals with stenosis MR-angiography demonstrated successful dilatation (n = 4). The normalized SI of the vessel wall on T1-weighted GE images significantly increased after the intervention in all animals with and without stenosis for more than 45 min. (p < 0.001). Conclusion: Monitoring of Gadolinium-BOPTA into the vessel wall during MR-guided coated balloon angioplasty is feasible. This is a first step towards providing a tool for the online control of homogenous drug delivery after paclitaxel-coated balloon angioplasty. (orig.)

  14. Distal coronary hemoperfusion during percutaneous transluminal coronary angioplasty

    NARCIS (Netherlands)

    deMuinck, ED; denHeijer, P; vanDijk, RB; Crijns, HJGM; Hillige, HL; Lie, KI

    1996-01-01

    Distal coronary hemoperfusion during percutaneous transluminal coronary angioplasty (PTCA)-with an autoperfusion balloon or active system-facilitates prolonged balloon inflation. Prolonged inflations may tack up intimal dissections and improve the primary angioplasty result in complex lesions. Addit

  15. Local Administration of NF-κ B Decoy Oligonucleotides to Prevent Restenosis after Balloon Angioplasty: An Experimental Study in New Zealand White Rabbits

    International Nuclear Information System (INIS)

    Purpose. To evaluate the efficacy of NF-κ B oligonucleotides (ODN) administered by local administration with the channeled balloon catheter to prevent restenosis after balloon angioplasty in restenotic iliac arteries of New Zealand white rabbits. Materials and Methods. In vitro, 8000 rabbit vascular smooth muscle cells (rVSMC) where transfected with a liposomal carrier (TfX50) with 100 ng of decoy and scrambled ODN. Inhibition of proliferation was measured using a MTT assay after 24 hours in comparison to control. In vivo, 22 male New Zealand White rabbits were fed a 1% cholesterol diet and received denudation of both common iliac arteries with a 3 mm balloon catheter to induce an arterial stenosis. Four weeks after stenosis induction, local application of NF-κ B in two different concentrations (1 μg: n = 14; 10 μg: n = 8) was performed randomly on one common iliac artery. Scrambled oligonucleotides without specific binding capacities were injected into the contralateral side. The channeled balloon catheter allows simultaneous balloon dilation (8 atm) of the stenosis and local application of a drug solution (2 atm). Four weeks after local drug delivery the animals were killed and the vessels were excised and computerized morphometric measurements were performed. Results. NF-κ B decoy ODN but not scrambled ODN inhibited proliferation of rVSMC in vitro. Following local ODN application in the animals, no acute vascular complications were seen. NF-κ B ODN resulted in a statistically non significant reduction of neointimal area compared to the control group. The neointimal area was 0.97 mm2 using 1 μg NF-κ B ODN compared to 0.98 mm2 in the control group. The higher dose resulted in a neointimal area of 0.97 mm2 compared to 1.07mm2 at the control side. Conclusions. Local drug delivery of NF-κ B ODN using the 'channeled balloon' catheter could not reduce neointimal hyperplasia in stenostic rabbit iliac arteries. Application modalities have to be improved to

  16. Randomized trial of Legflow® paclitaxel eluting balloon and stenting versus standard percutaneous transluminal angioplasty and stenting for the treatment of intermediate and long lesions of the superficial femoral artery (RAPID trial): Study protocol for a randomized controlled trial

    NARCIS (Netherlands)

    A. Karimi; S.W. de Boer (Sanne W.); D.A.F. Van Den Heuvel; B. Fioole (Bram); D. Vroegindeweij (Dammis); J.M.M. Heyligers (Jan); P.N.M. Lohle (Paul N.M.); O.E. Elgersma (Otto E.); R.P.T. Nolthenius (Rudolf ); J.A. Vos (Jan Albert); J.-P.P.M. de Vries (Jean-Paul)

    2013-01-01

    textabstractBackground: Restenosis after percutaneous transluminal angioplasty (PTA) of the superficial femoral artery (SFA) may occur in 45% of patients at 2 years follow-up. Paclitaxel-coated balloons have been found to reduce neointimal hyperplasia, and thus reduce restenosis. Recently, the Legfl

  17. 切割球囊扩张在股浅动脉长段闭塞治疗中的作用%Angioplasty with cutting balloon in patient with long segmental obstruction of superficial femoral artery

    Institute of Scientific and Technical Information of China (English)

    王爱林; 徐恒; 刘军; 韩圣辉

    2012-01-01

    Objective To compare the technical success rate and midterm results of cutting balloon angioplasty (CBA) to conventional balloon angioplasty (BA) for treatment of long segmental obstruction of the superficial femoral artery. Methods Between March 2009 and May 2010, 33 patients with long segmental obstruction of the superficial femoral artery treated with conventional angioplasty underwent cutting angioplasty. Follow-up consisted clinical examination and computed tomographic angiography at interval of one year. Results After conventional angioplasty there were still severe stenoses in the treated segments of the superficial femoral artery among the 33 selected patients. The stenosis rate decreased from 60% -95% (average 78%) post-conventional angioplasty to 15% -45% (average 36%) after cutting balloon angioplasty. Three patients complicated minor vessel dissection without other major complication. The one year patency of the cutting balloon angioplasty was 66% , which is better than the patency of the conventional balloon angioplasty ( 37% ) . Conclusion Cutting balloon angioplasty provides better vessel patency additional to balloon angioplasty in the treatment of the long segmental obstruction of the superficial femoral artery.%目的 分析评价在常规球囊扩张基础上加用切割球囊治疗股浅动脉长段闭塞的治疗效果和中期通畅率.方法 应用了切割球囊扩张治疗33例股浅动脉长段闭塞患者,导丝通过闭塞段后,首先应用常规球囊进行扩张后,进行动脉造影,对常规球囊扩张后仍有明显狭窄部位进行切割球囊扩张,再次动脉造影评价切割球囊扩张效果.术后对经过治疗的24例患者进行1年的中期随访,并与前期完成的24例单纯常规球囊扩张的1年通畅率进行比较,总结分析两者的中期通畅率、再狭窄的病变特点.结果 在股浅动脉长段闭塞部位进行常规球囊扩张后,均存在不同部位的短段重度狭窄,狭窄部位位于

  18. Unintended Thermal Injuries from Radiofrequency Ablation: Organ Protection with an Angioplasty Balloon Catheter in an Animal Model

    Directory of Open Access Journals (Sweden)

    Martha-Grace Knuttinen

    2014-01-01

    Full Text Available Objectives: The aim of this study was to investigate a novel approach of using a balloon catheter as a protective device to separate liver from the diaphragm or nearby bowel during radiofrequency ablation (RFA of hepatic dome tumors in an animal model. Materials and Methods: All experimental procedures were approved by animal Institutional Review Board. Using a 3 cm RF needle electrode, 70 hepatic ablation zones were created using ultrasound in 7 pigs. 50 lesions were created using balloon interposition between liver and diaphragm; 20 lesions were created using the balloon device interposed posteriorly between liver and bowel. Additional 21 control lesions were performed. Animals were sacrificed immediately; diaphragm and bowel were then visually inspected and sectioned. Diaphragmatic and bowel injury was then classified according to the depth of thickness. Results: Control lesions caused full thickness injury, either to diaphragm or bowel. During ablation of lesions with balloon interposition, there was significantly less diaphragmatic injury, P < 0.001 and less bowel injury, P < 0.01. Conclusion: Using balloon interposition as a protective device has advantages over previous saline infusion or CO 2 insufflation, providing a safe way to expand percutaneous RFA of liver tumors located on the undersurface of the diaphragm. In addition, this method may be used in protection of other organs adjacent to areas being ablated.

  19. Drug-eluting versus plain balloon angioplasty for the treatment of failing dialysis access: Final results and cost-effectiveness analysis from a prospective randomized controlled trial (NCT01174472)

    Energy Technology Data Exchange (ETDEWEB)

    Kitrou, Panagiotis M., E-mail: panoskitrou@gmail.com [Department of Interventional Radiology, Patras University Hospital, School of Medicine, Rion 26504 (Greece); Katsanos, Konstantinos [Department of Interventional Radiology, Guy' s and St. Thomas’ Hospitals, NHS Foundation Trust, King' s Health Partners, London SE1 7EH (United Kingdom); Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris [Department of Interventional Radiology, Patras University Hospital, School of Medicine, Rion 26504 (Greece)

    2015-03-15

    Highlights: •1-Year target lesion primary patency significantly higher after PCB application compared to plain balloon angioplasty in the failing dialysis access. •Significant difference in favor of PCB in cumulative primary patency of AVGs at 1 year. •No significant difference in cumulative primary patency of AVFs treated with PCB at 1 year. •Cost effectiveness analysis performed. •Paclitaxel-coated balloon angioplasty proves to be a cost-effective option for treating dialysis access. -- Abstract: Objective: To report the final results and cost-effectiveness analysis of a prospective randomized controlled trial investigating drug-eluting balloon (DEB) versus plain balloon angioplasty (BA) for the treatment of failing dialysis access ( (NCT01174472)). Methods: 40 patients were randomized to angioplasty with either DEB (n = 20) or BA (n = 20) for treatment of significant venous stenosis causing a failing dialysis access. Both arteriovenous fistulas (AVF) and synthetic arteriovenous grafts (AVG) were included. Angiographic follow up was scheduled every two months. Primary endpoints were technical success and target lesion primary patency at 1 year. Cumulative and survival analysis was performed. Incremental net benefit (INB) and incremental cost effectiveness ratio (ICER) were calculated and the cost-effectiveness acceptability curve (CEAC) was drawn. Results: Baseline variables were equally distributed between the two groups. At 1 year, cumulative target lesion primary patency was significantly higher after DEB application (35% vs. 5% after BA, p < 0.001). Overall, median primary patency was 0.64 years in case of DEB vs. 0.36 years in case of BA (p = 0.0007; unadjusted HR = 0.27 [95%CI: 0.13–0.58]; Cox adjusted HR = 0.23 [95%CI: 0.10–0.50]). ICER was 2198 Euros (€) per primary patency year of dialysis access gained. INB was 1068€ (95%CI: 31–2105€) for a willingness-to-pay (WTP) threshold of 5000€ (corresponding acceptability probability >97

  20. Drug-eluting versus plain balloon angioplasty for the treatment of failing dialysis access: Final results and cost-effectiveness analysis from a prospective randomized controlled trial (NCT01174472)

    International Nuclear Information System (INIS)

    Highlights: •1-Year target lesion primary patency significantly higher after PCB application compared to plain balloon angioplasty in the failing dialysis access. •Significant difference in favor of PCB in cumulative primary patency of AVGs at 1 year. •No significant difference in cumulative primary patency of AVFs treated with PCB at 1 year. •Cost effectiveness analysis performed. •Paclitaxel-coated balloon angioplasty proves to be a cost-effective option for treating dialysis access. -- Abstract: Objective: To report the final results and cost-effectiveness analysis of a prospective randomized controlled trial investigating drug-eluting balloon (DEB) versus plain balloon angioplasty (BA) for the treatment of failing dialysis access ( (NCT01174472)). Methods: 40 patients were randomized to angioplasty with either DEB (n = 20) or BA (n = 20) for treatment of significant venous stenosis causing a failing dialysis access. Both arteriovenous fistulas (AVF) and synthetic arteriovenous grafts (AVG) were included. Angiographic follow up was scheduled every two months. Primary endpoints were technical success and target lesion primary patency at 1 year. Cumulative and survival analysis was performed. Incremental net benefit (INB) and incremental cost effectiveness ratio (ICER) were calculated and the cost-effectiveness acceptability curve (CEAC) was drawn. Results: Baseline variables were equally distributed between the two groups. At 1 year, cumulative target lesion primary patency was significantly higher after DEB application (35% vs. 5% after BA, p < 0.001). Overall, median primary patency was 0.64 years in case of DEB vs. 0.36 years in case of BA (p = 0.0007; unadjusted HR = 0.27 [95%CI: 0.13–0.58]; Cox adjusted HR = 0.23 [95%CI: 0.10–0.50]). ICER was 2198 Euros (€) per primary patency year of dialysis access gained. INB was 1068€ (95%CI: 31–2105€) for a willingness-to-pay (WTP) threshold of 5000€ (corresponding acceptability probability >97

  1. Factors influencing technical success and outcome of percutaneous balloon angioplasty in de novo native hemodialysis arteriovenous fistulas

    Energy Technology Data Exchange (ETDEWEB)

    Heye, Sam, E-mail: sam.heye@uzleuven.be [University Hospitals Leuven, Department of Radiology, Herestraat 49, 3000 Leuven (Belgium); Maleux, Geert, E-mail: geert.maleux@uzleuven.be [University Hospitals Leuven, Department of Radiology, Herestraat 49, 3000 Leuven (Belgium); Vaninbroukx, Johan, E-mail: johan.vaninbroukx@uzleuven.be [University Hospitals Leuven, Department of Radiology, Herestraat 49, 3000 Leuven (Belgium); Claes, Kathleen, E-mail: Kathleen.claes@uzleuven.be [University Hospitals Leuven, Department of Nephrology, Herestraat 49, 3000 Leuven (Belgium); Kuypers, Dirk, E-mail: dirk.kuypers@uzleuven.be [University Hospitals Leuven, Department of Nephrology, Herestraat 49, 3000 Leuven (Belgium); Oyen, Raymond, E-mail: raymond.oyen@uzleuven.be [University Hospitals Leuven, Department of Radiology, Herestraat 49, 3000 Leuven (Belgium)

    2012-09-15

    Objective: To determine predictors of technical success, dysfunction recurrence and patency after percutaneous transluminal angioplasty (PTA) of de novo dysfunctional hemodialysis arteriovenous fistulas (AVFs). Methods: Retrospective analysis of first time PTA of 167 AVF in 162 patients (100 men, 66 ± 13 years). Anatomical (location, length, grade and number of stenoses) and clinical variables (sex, age, prior AVF, diabetes mellitus and AVF age, side and location) were reviewed. Results: 217 stenoses or segmental occlusions were treated. Technical success rate (84.4%) was higher in radiocephalic AVF compared to brachial artery–median vein AVF (p = 0.030) and was negatively correlated with initial stenosis (p = 0.049). Dysfunction recurrence was seen in 52.7% and correlated negatively with technical success (p = 0.013) and AVF age (p = 0.008). Early dysfunction (within 6 months) was negatively correlated with AVF age (p = 0.016) and positively with diabetes (p = 0.003). Higher AVF age resulted in higher primary (p = 0.005) and secondary patency rates (p = 0.037–0.005). Conclusions: Technical success of PTA in hemodialysis AVF is affected by AVF type and initial stenosis and has significant effect on dysfunction recurrence, but not on AVF longevity. Younger AVF has increased risk for (early) recurrent dysfunction and lower patency rates. Patients with diabetes mellitus have higher risk for early dysfunction.

  2. Percutaneous Balloon Angioplasty for Severe Native Aortic Coarctation in Young Infants Less Than 6 Months: Medium-to Long-term Follow-up

    Institute of Scientific and Technical Information of China (English)

    Lan He; Fang Liu; Lin Wu; Chun-Hua Qi; Li-Feng Zhang; Guo-Ying Huang

    2015-01-01

    Background:Although balloon angioplasty (BA) has been performed for more than 20 years,its use as a treatment for native coarctation of the aorta (CoA) during childhood,especially in young infants,remains controversial.This study aimed to assess the effects and potential role of percutaneous transcatheter BA for native CoA as an alternative therapy to surgical repair in young infants.Methods:The 37 patients aged from 6 days to 6 months with severe CoA in congestive heart failure or circulatory shock were admitted for BA.Patient's weight ranged from 2.4 to 6.1 kg.All 37 patients were experiencing cardiac dysfunction,and eight patients were in cardiac shock with severe metabolic acidosis.Eleven patients had an isolated CoA,whereas the others had a CoA associated with other cardiac malformations.Cardiac catheterization and aortic angiography were performed under general anesthesia with intubation.Transfemoral arterial approaches were used for the BA.The size of the balloon ranged from 3 mm × 20 mm to 8 mm × 20 mm,and a coronary artery balloon catheter was preferred over a regular peripheral vascular balloon catheter.Results:The femoral artery was successfully punctured in all but one patient,with that patient undergoing a carotid artery puncture.The systolic peak pressure gradient (PG) across the coarctation was 41.0 ± 16.0 mmHg (range 13-76 mmHg).The mean diameter of the narrowest coarctation site was 1.7 ± 0.6 mm (range 0.5-2.8 mm).All patients had successful dilation;the PG significantly decreased to 13.0 ± 1 1.0 mmHg (range 0-40 mmHg),and the diameter of coarctation significantly improved to 3.8 ± 0.9 mm (range 2.5-5.3 mm).No intraoperative complications occurred for any patients.However,in one case that underwent a carotid artery puncture,a giant aneurysm formed at the puncture site and required surgical repair.The following observations were made during the follow-up period from 6-month to 7-year:(1) The PG across the coarctation measured by

  3. MYOCARDIAL PROTECTION DURING CORONARY ANGIOPLASTY WITH AUTOPERFUSION AND FORCED PERFUSION - AN IN-VITRO COMPARISON

    NARCIS (Netherlands)

    DEMUINCK, ED; VERKERKE, BJ; RAKHORST, G; LIE, KI

    1994-01-01

    During coronary angioplasty, perfusion distal to the inflated angioplasty balloon can be maintained with autoperfusion balloon catheters and coronary perfusion pumps. The blood flow rates through the autoperfusion balloon catheters and the flow rates achieved with a perfusion pump were compared in v

  4. Laser angioplasty for cardiovascular disease

    Science.gov (United States)

    Okada, Masayoshi

    2005-07-01

    Recently, endovascular interventions such as balloon angioplasty, atherectomy and the stenting method, except for conventional surgery have been clinically employed for the patients with atheromatous plaques of the peripheral- and the coronary arteries, because the number of patients with arteriosclerosis is now increasing in the worldwide. Among these procedures, restenoses after endovascular interventions have been remarkably disclosed in 20-40 % of the patients who underwent percutaneous coronary interventions. Thus, there are still some problems in keeping long-term patency by means of endovascular techniques such as balloon angioplasty and atherectomy (1, 2). For reduction of these problems , laser angioplasty using Argon laser was applied experimentally and clinically. Based on excellent experimental studies, laser was employed for 115 patients with stenotic ,or obstructive lesions occluding more thasn 75 % of the peripheral and the coronary arteries angiographycally.

  5. Morphologic alterations after transluminal angioplasty

    International Nuclear Information System (INIS)

    Despite the widespread clinical use of percutaneous transluminal angioplasty, the mechanism by which enlargement of the arterial lumen is achieved by this technique has been poorly understood. In the original description of transluminal angioplasty in 1964, the effectiveness of the procedure was attributed to compression of the atheromatous plaque against a relatively unyielding artery wall. This mechanism was subsequently endorsed in relation to angioplasty using the balloon catheter. The concept of plaque compression or displacement or of herniation of the puttylike athermatous intima into the artery wall was generally accepted by the early pioneers in transluminal angioplasty. This mechanism did not, however, correspond to clinical and morphologic observations that plaques were generally rigid and calcific rather than plastic and could not readily be compressed or deformed. Angiographic observations before and after dilatation have not always been helpful in defining the mechanism since angiography reveals only the lumen contour and does not provide sufficient information concerning the thickness of the arterial wall or the size, configuration, or precise boundaries of plaques. Although direct observation of lesions and associated artery walls immediately after balloon dilatation could provide the necessary information, such data are difficult to obtain since arteries and plaques are rarely directly inspected after dilatation in the living patient. Knowledge of the morphologic consequences of balloon dilatation in human arteries has therefore been obtained mainly from experimental studies of postmortem arteries and corresponding angiographic images and from specimens obtained from amputated limbs or after death

  6. Local hemodynamic changes caused by main branch stent implantation and subsequent virtual side branch balloon angioplasty in a representative coronary bifurcation.

    Science.gov (United States)

    Williams, Andrew R; Koo, Bon-Kwon; Gundert, Timothy J; Fitzgerald, Peter J; LaDisa, John F

    2010-08-01

    Abnormal blood flow patterns promoting inflammation, cellular proliferation, and thrombosis may be established by local changes in vessel geometry after stent implantation in bifurcation lesions. Our objective was to quantify altered hemodynamics due to main vessel (MV) stenting and subsequent virtual side branch (SB) angioplasty in a coronary bifurcation by using computational fluid dynamics (CFD) analysis. CFD models were generated from representative vascular dimensions and intravascular ultrasound images. Time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and fractional flow reserve (FFR) were quantified. None of the luminal surface was exposed to low TAWSS (stenting introduced eccentric areas of low TAWSS along the lateral wall of the MV. Virtual SB angioplasty resulted in a more concentric region of low TAWSS in the MV distal to the carina and along the lateral wall of the SB. The luminal surface exposed to low TAWSS was similar before and after virtual SB angioplasty (rest: 43% vs. 41%; hyperemia: 18% vs. 21%) and primarily due to stent-induced flow alterations. Sites of elevated OSI (>0.1) were minimal but more impacted by general vessel geometry established after MV stenting. FFR measured at a jailed SB was within the normal range despite angiographic stenosis of 54%. These findings indicate that the most commonly used percutaneous interventional strategy for a bifurcation lesion causes abnormal local hemodynamic conditions. These results may partially explain the high clinical event rates in bifurcation lesions.

  7. Coronary Angioplasty

    Science.gov (United States)

    ... page from the NHLBI on Twitter. What Is Percutaneous Coronary Intervention? Español Percutaneous (per-ku-TA-ne-us) coronary intervention (PCI), commonly known as coronary angioplasty (AN-jee- ...

  8. Novel paclitaxel-coated angioplasty balloon catheter based on cetylpyridinium salicylate: Preparation, characterization and simulated use in an in vitro vessel model

    International Nuclear Information System (INIS)

    Drug-coated balloons (DCB), which have emerged as therapeutic alternative to drug-eluting stents in percutaneous cardiovascular intervention, are well described with regard to clinical efficiency and safety within a number of clinical studies. In vitro studies elucidating the correlation of coating method and composition with DCB performance are however rare but considered important for the understanding of DCB requirements and the improvement of established DCB. In this context, we evaluated the applicability of a pipetting, dip-coating, and spray-coating process for the establishment of DCB based on paclitaxel (PTX) and the ionic liquid cetylpyridinium salicylate (Cetpyrsal) as novel innovative additive in three different compositions. Among tested methods and compositions, the pipetting process with 50 wt.% PTX resulted in most promising coatings as drug load was less controllable by the other processes and higher PTX contents led to considerable drug crystallization, as visualized by electron microscopy, accelerating PTX loss during short-term elution. Applying these conditions, homogeneous coatings could be applied on balloon catheter, whose simulated use in an in vitro vessel model revealed percental drug losses of 36 and 28% during transit and percental drug transfers of 12 and 40% under expansion for coatings applied in expanded and folded balloon condition, respectively. In comparison to literature values, these results support the high potential of Cetpyrsal as novel DCB matrix regarding low drug loss and efficient drug transfer. - Highlights: • We provide detailed in vitro data for definition of DCB coating requirements. • An in vitro vessel model for evaluating drug delivery from DCB is presented. • Innovative ionic liquid-based coatings for DCB are developed. • The coating shows low drug loss and efficient drug transfer

  9. Novel paclitaxel-coated angioplasty balloon catheter based on cetylpyridinium salicylate: Preparation, characterization and simulated use in an in vitro vessel model

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, Svea, E-mail: svea.petersen@uni-rostock.de [Institute for Biomedical Engineering, University of Rostock, Friedrich-Barnewitz-Straße 4, 18119 Rostock (Germany); Kaule, Sebastian [Institute for Biomedical Engineering, University of Rostock, Friedrich-Barnewitz-Straße 4, 18119 Rostock (Germany); Stein, Florian [Institute for Chemistry, Analytical and Technical Chemistry University of Rostock, Albert-Einstein-Straße 3a, 18059 Rostock (Germany); Minrath, Ingo; Schmitz, Klaus-Peter [Institute for Biomedical Engineering, University of Rostock, Friedrich-Barnewitz-Straße 4, 18119 Rostock (Germany); Kragl, Udo [Institute for Chemistry, Analytical and Technical Chemistry University of Rostock, Albert-Einstein-Straße 3a, 18059 Rostock (Germany); Sternberg, Katrin [Institute for Biomedical Engineering, University of Rostock, Friedrich-Barnewitz-Straße 4, 18119 Rostock (Germany)

    2013-10-15

    Drug-coated balloons (DCB), which have emerged as therapeutic alternative to drug-eluting stents in percutaneous cardiovascular intervention, are well described with regard to clinical efficiency and safety within a number of clinical studies. In vitro studies elucidating the correlation of coating method and composition with DCB performance are however rare but considered important for the understanding of DCB requirements and the improvement of established DCB. In this context, we evaluated the applicability of a pipetting, dip-coating, and spray-coating process for the establishment of DCB based on paclitaxel (PTX) and the ionic liquid cetylpyridinium salicylate (Cetpyrsal) as novel innovative additive in three different compositions. Among tested methods and compositions, the pipetting process with 50 wt.% PTX resulted in most promising coatings as drug load was less controllable by the other processes and higher PTX contents led to considerable drug crystallization, as visualized by electron microscopy, accelerating PTX loss during short-term elution. Applying these conditions, homogeneous coatings could be applied on balloon catheter, whose simulated use in an in vitro vessel model revealed percental drug losses of 36 and 28% during transit and percental drug transfers of 12 and 40% under expansion for coatings applied in expanded and folded balloon condition, respectively. In comparison to literature values, these results support the high potential of Cetpyrsal as novel DCB matrix regarding low drug loss and efficient drug transfer. - Highlights: • We provide detailed in vitro data for definition of DCB coating requirements. • An in vitro vessel model for evaluating drug delivery from DCB is presented. • Innovative ionic liquid-based coatings for DCB are developed. • The coating shows low drug loss and efficient drug transfer.

  10. Angioplasty and stent placement -- peripheral arteries

    Science.gov (United States)

    Percutaneous transluminal angioplasty - peripheral artery; PTA - peripheral artery; Angioplasty - peripheral arteries; Iliac artery -angioplasty; Femoral artery - angioplasty; Popliteal artery - angioplasty; Tibial ...

  11. 球囊血管成形术对血浆TNF-α、ET水平及局部血管组织ET-IR的影响%Effect of balloon angioplasty on plasma ET and TNF-α levels and tissue endothe lin immunoreactivity in experimental atherosclerotic rabbits

    Institute of Scientific and Technical Information of China (English)

    杜荣增; 吴宗贵; 黄佐; 黄高忠; 张国元

    2001-01-01

    目的 :通过建立兔髂动脉粥样硬化(AS)模型,观察球囊 血管成形术(BA)对血浆肿瘤坏死因子α(TNF-α)、内皮素(ET)水平及局部血管组织E T免疫反应性(ET-IR)的影响。方法:20只新西兰雄性大白兔经高脂饲 料喂养至少8周造成AS,然后进行髂动脉BA,18只兔获得成功。检测了BA前、即刻及24 h后 血浆ET和TNF-α水平,ET采用放射免疫法测定,TNF-α采用生物活性法测定。同时,应用 免疫组织化学技术评价血管组织ET-IR。结果:BA前后即刻:血浆ET水 平(pg/ml)分别为76.4±13.58和92.67±11.38(P0.05);而血浆TNF-α水平(U/ml)分别为31.35±6.23和56.26±7.37(P 0.05)。 BA后局部髂动脉血管壁ET-IR较未经BA的髂动脉明显增加。结论:BA 后血浆ET、TNF-α水平升高及局部血管壁ET-IR增加可能与局部血管内膜损伤有关,提示E T、TNF-α可能参与了PTCA后急性冠脉收缩及再狭窄过程。%Objective: To assess the effect of balloon angiopl asty on circulating endothelin (ET) and TNF-α levels and tissue endothelin in experimental atherosclerosis in rabbits. Methods: After 20 New Z ealand rabbits had a high cholesterol diet for at least 8 weeks, successful ball oon angioplasty was performed in rihgt iliac arteries in 18 rabbits. Circulatin g levels of ET and TNF-α were measured before as well as immediately and 24 h after balloon angioplasty. Tissue endothelin immunoreactivity in atherosclerotic iliac artery wall after balloon angioplasty was assessed by immunohistochemica l technique. Results: Plasma levels of ET and TNF-α were signi ficantly increased immediately after ballon angioplasty (76.40±13.58)pg/ml vs (92.67±11.38) pg/ml and (31.35±6.23) U/ml vs (56.26±7.37) U/ml, resp ectively (P0.05). T issue endothelin immunoreactiuvity was markedly increased in right iliac artery wall after balloon angioplasty than that in opposite iliac artery wall. Conclusion: The increase of plasma

  12. Angioplasty and stent placement - heart

    Science.gov (United States)

    ... angioplasty; Coronary artery angioplasty; Percutaneous transluminal coronary angioplasty; Heart artery dilatation ... to carefully guide the catheter up into your heart and arteries. Dye will be injected into your ...

  13. Intravascular ultrasound imaging following balloon angioplasty.

    OpenAIRE

    Tobis, JM; Mahon, DJ; Moriuchi, M; Honye, J; McRae, M

    1991-01-01

    Despite its long history and reliability, contrast angiography has several inherent limitations. Because it is a two-dimensional projection image of the lumen contour, the wall thickness cannot be measured and the plaque itself is not visualized. This results in an underestimation of the amount of atherosclerotic disease by angiography. An assessment of atherosclerosis could be improved by an imaging modality: (1) that has an inherent larger magnification than angiography and (2) that directl...

  14. Percutaneous endoluminal angioplasty of post endarterectomy carotid stenoses

    International Nuclear Information System (INIS)

    Percutaneous transluminal angioplasty of the carotid artery was performed in four patients with recurrent stenosis following endarterectomy. Balloon catheter dilatation was successful in 3 of the 4 lesions. Post dilatation angiography demonstrated an increase in luminal diameter: there were no neurological complications with the procedure. PTA appears to be an effective method of treating recurrent stenosis following carotid endarterectomy. (orig.)

  15. Distal coronary hemoperfusion during percutaneous transluminal coronary angioplasty

    NARCIS (Netherlands)

    Muinck, Ebo Derk de

    1994-01-01

    In this thesis several aspects of passive and active coronary perfusion during coronary angioplasty are investigated. The autoperfusion balloon catheters that were evaluated are the Stack® and the RX-60® catheters (Advanced Cardiovascular Systems, inc., Santa Clara, California, U.S.A). The coronary

  16. Segmentally enclosed thrombolysis in percutaneous transluminal angioplasty for femoropopliteal occlusions

    DEFF Research Database (Denmark)

    Jørgensen, B; Tønnesen, K H; Nielsen, J D;

    1991-01-01

    Segmentally enclosed thrombolysis (SET) was performed immediately following 34 percutaneous transluminal angioplasties (PTAs) for femoropopliteal occlusions. The dilated segment was sealed off with a double balloon catheter, and recombinant tissue plasminogen activator (rt-PA) 1 mg/ml and heparin...

  17. Safety and efficacy of recombinant Hirudin (CGP 39 393) versus Heparin in patients with stable angina undergoing coronary angioplasty

    NARCIS (Netherlands)

    A.A. van den Bos (Arjan); G.R. Heyndrickx (Guy); G-J. Laarman (GertJan); H. Suryapranata (Harry); F. Zijlstra (Felix); P. Close (Philip); J.J.M.M. Rijnierse (Joep); H.R. Büller (Harry); P.W.J.C. Serruys (Patrick); J.W. Deckers (Jaap)

    1993-01-01

    textabstractBACKGROUND. Enhanced thrombin activity has been associated with acute and long-term complications following balloon angioplasty (percutaneous transluminal coronary angioplasty (PTCA). We evaluated, in a 2-to-1 randomized, double-blind trial, the effects of recombinant hirudin, CGP 39 393

  18. THE KISSING BALLOON TECHNIQUE WITH 2 OVER-THE-WIRE BALLOON CATHETERS THROUGH A SINGLE 8-FRENCH GUIDING CATHETER

    NARCIS (Netherlands)

    DENHEIJER, P; BERNINK, PJLM; VANDIJK, RB; TWISK, SPM; LIE, KI

    1991-01-01

    Some of the newer over-the-wire coronary angioplasty catheters have shaft sizes of 3.0 French (F) or less. The inner diameter of modern 8-F guiding catheters is large enough to accommodate two of such balloon catheters. We report a kissing balloon procedure with two over-the-wire catheters through a

  19. 微创Sky手术与球囊成形术治疗脊柱骨质疏松压缩性骨折的效果比较%Comparative study on the effect of Sky minimally invasive surgery and balloon angioplasty in the treatment of spinal osteoporotic compression fractures

    Institute of Scientific and Technical Information of China (English)

    吕海文

    2016-01-01

    Objective To compare the effect of Sky minimally invasive surgery and balloon angioplasty in the treatment of spinal osteoporotic compression fractures.Methods 61 cases of spinal osteoporotic compression fractures in our hospital from April 2012 to August 2013 were selected and divided into two groups according to the random number table,of whom 30 cases were treated with Sky bone expander surgery (Sky group),31 cases were treated with percutaneous balloon vertebroplasty (balloon group).Compared the effect of two groups combined with postoperative follow-up.Results There was no statistically significant difference in treatment efficiency between Sky group and balloon group (93.3% vs.93.5%,P>0.05).There were no statistically significant differences in operation time,intraoperative blood loss and self-rating pain score between Sky group and balloon group [(41.4±5.3)min vs.(39.5±5.5)min,(17.6±4.1)ml vs.(19.0±4.3)ml,(2.9± 1.1) vs.(3.1 ± 1.0);P>0.05].There were no postoperative complications in both two groups.Conclusion Sky minimally invasive surgery and balloon angioplasty are both effective methods for the treatment of spinal osteoporotic compression fractures,which can significantly improve spinal function and relief spinal pain.%目的 比较微创Sky手术与球囊成形术治疗脊柱骨质疏松压缩性骨折的效果.方法 选取我院2012年4月至2013年8月61例脊柱骨质疏松压缩性骨折患者,根据随机数表分为两组,其中30例采用Sky骨扩张器手术治疗(记为Sky组),31例采用经皮球囊扩张椎体成形术治疗(记为球囊组).结合术后随访观察两组治疗效果.结果 Sky组治疗有效率相较球囊组差异无统计学意义(93.3%vs.93.5%,P>0.05);Sky组手术时长[(41.4±5.3) min]、术中出血量[(17.6±4.1)ml]、患者自我疼痛评分(2.9±1.1)与球囊组[(39.5±5.5) min、(19.0±4.3) ml、(3.1±1.0)]相比,差异无统计学意义(P>0.05);两组术后均未出现并发症.结论 微

  20. Changes of nitric oxide and endothelin serum level after carotid balloon denudation or stent assisted angioplasty: an experimental and clinical observation%颈动脉球囊扩张与支架置入术后血清一氧化氮和内皮素变化的实验与临床观察

    Institute of Scientific and Technical Information of China (English)

    刘加春; 王大明; 钱江南; 李雅国; 王利军; 姜学丽; 翟乐乐; 陆军; 祁鹏

    2009-01-01

    Objective To observe the changes of nitric oxide (NO) and endothelin (ET) serum level in the Guangxi BA-MA minipigs whose carotid arteries were injured by balloon denudation and in the patients with catotid stent assisted angioplasty. Methods Twelve Guangxi BA-MA minipigs were choosen. High fat/cholesterol feeding and endovascular balloon denudation were used to create a carotid artery atherosclerotic stenosis animal model. Blood samples were collected from peripheral veins before starting the procedure, and again, at 2 and 3 weeks after the procedure, respectively. Serum NO and ET concentrations of blood samples were tested. Nineteen patients with carotid artery stenosis who underwent stent assisted angioplasty were randomly selected, and their serum NO and ET were tested using the same methods as above. Results In the animal group, there was a significant decrease of mean NO concentration at 2 weeks after carotid injury (t-test, P<0.05 ), however, no significant change of ET was observed. A very significant increase of ET was observed at 3 weeks after the procedure (t-test, P <0.01 ). In the patient group, there were no significant differences among serum NO or ET concentration of peripheral vein blood before, immediately after, and 6 h after the endovascular treatment. Conclusions In this study, a decrease of NO concentration and an increase of ET concentration of peripheral vein blood are found in BA-MA minipigs after carotid arteries are injured by balloon denudation, which might be a cue for the formation of atherosclerosis. However, no significant changes are observed in this group of patients who underwet carotid angioplasty treatment. Therefore, further studies are needed.%目的:观察小型猪颈动脉球囊扩张前后和颈动脉狭窄患者狭窄扩张、支架置入术前后血清一氧化氮(NO)和内皮素(ET)的变化.方法:选取12头广西巴马小型猪,分别于颈动脉球囊损伤前、损伤后2周和3周检测静脉血血清中NO

  1. [Role of angioplasty in the treatment of renal artery stenosis].

    Science.gov (United States)

    Armero, S; Bonello, L; Paganelli, F; Barragan, P; Roquebert, P-O; Commeau, P

    2011-12-01

    Atherosclerotic renal artery stenosis is frequent and is associated with a high incidence of morbidity and mortality, with a strong correlation with coronary artery disease, (Kalra et al., 2005; Cheung et al., 2002; Guo et al., 2007 [1-3]). The atherosclerotic renal artery stenosis is an independent predictive factor of death (Conlon et al., 1998 [4]). The treatment of this lesion does not have strong evidence. A lot of studies in this area suggest the angioplasty is superior in a big majority between surgery, and angioplasty with stent is superior between balloon angioplasty, but some studies fail to prove the superiority of angioplasty versus medical treatment. These studies have sadly a lot of mistakes and nowadays we don't know what is the treatment for our patients in a lot of cases. The angioplasty is indicated when there is a failure of antihypertensive medications for control of blood pressure, when it is associated with a renal insufficiency quickly progressive or when there is a lesion on each renal artery. Other studies must be organized for prove the superiority of angioplasty when there is a real stenosis, maybe with the use of fractional flow reserve.

  2. Angioplasty and stent placement - carotid artery

    Science.gov (United States)

    Carotid angioplasty and stenting; CAS; Angioplasty - carotid artery; Carotid artery stenosis - angioplasty; ... Carotid angioplasty and stenting (CAS) is done using a small surgical cut. Your surgeon will make a surgical cut ...

  3. Coronary Angioplasty Stent Placement

    Medline Plus

    Full Text Available Coronary Angioplasty Stent Placement Shawnee Mission Heart & Vascular Center, Shawnee Mission, Kansas February 19, 2009 Welcome to this OR-Live westbound cast presentation, live from Shawnee Mission Medical Center ...

  4. Protective effect of collateral vessels during coronary angioplasty.

    OpenAIRE

    Norell, M. S.; Lyons, J. P.; Gardener, J E; Layton, C A; Balcon, R

    1989-01-01

    To assess the potential protective role of collateral vessels 27 patients undergoing angioplasty of the left anterior descending coronary artery were studied by intravenous digital subtraction left ventriculography. Fifteen patients had no collateral vessels (group 1) and 12 had some degree of collateral supply (group 2). During balloon inflation ST segment elevation in group 1 (4.9 mm) was significantly greater than that in group 2 (0.9 mm). Similarly the reduction in left ventricular ejecti...

  5. 可注射珊瑚人工骨与经皮球囊成型修复股骨头坏死%Percutaneous balloon angioplasty combined with injectable coral artificial bone repairs femoral head necrosis

    Institute of Scientific and Technical Information of China (English)

    朱康华; 孟志斌; 黄涛; 谭海涛; 孙博; 庞学毅

    2016-01-01

    BACKGROUND: There are many methods for the treatment of femoral head necrosis, such as core decompression, bone graft, arthroplasty and joint replacement, and each of which has its own shortcomings. So, percutaneous bal oon angioplasty combined with coral artificial bone provides a new attempt for the treatment of femoral head necrosis. OBJECTIVE: To observe the effect of percutaneous bal oon angioplasty combined with coral artificial bone on femoral head necrosis repair. METHODS: Twenty-four Duroc piglets were enrol ed to establish bilateral femoral head necrosis models by liquid nitrogen freezing method. Then, model piglets were randomly treated with percutaneous bal oon angioplasty combined with injectable coral artificial bone (experimental group) or bone cement (control group) on one affected side, and meanwhile, given no treatment on the contralateral side (blank control group). At 2, 4, 8 and 16 weeks after surgery, X-ray examination, biomechanical test and histological detection were conducted. RESULTS AND CONCLUSION: X-ray showed that at 16 weeks after surgery, numerous new bones could be found in the experimental group and there was a fuzzy boundary between the artificial bone and surrounding tissues; no new bone formed in the control group, and the boundary was clear; in the blank control group, the surface of the femoral head col apsed, and bone trabeculae arranged disorderly, which were seriously destroyed. And in the histological detection at 16 weeks after surgery, there were numerous bone trabecula and osteoblasts around the coral bone in the experimental group, and the coral artificial bone almost dissolved; in the control group, bone cement was in an irregular shape and no bone trabecula formed; in the blank control group, bone trabecula were damaged in the col apsed area, whose structure was in disorder. Additional y, biomechanical changes in the experimental group were significantly better than those in the other two groups at different time

  6. Femoral artery recanalisation with percutaneous angioplasty and segmentally enclosed plasminogen activator

    DEFF Research Database (Denmark)

    Jørgensen, B; Tønnesen, K H; Bülow, J;

    1989-01-01

    To establish whether re-occlusion of the femoral artery could be prevented, in 6 consecutive patients undergoing percutaneous transluminal angioplasty (PTA) for superficial femoral artery occlusion the recanalised segment was isolated, with a 7-French double-balloon catheter. 5 mg recombined human...

  7. Angioplasty simulation using ChainMail method

    Science.gov (United States)

    Le Fol, Tanguy; Acosta-Tamayo, Oscar; Lucas, Antoine; Haigron, Pascal

    2007-03-01

    Tackling transluminal angioplasty planning, the aim of our work is to bring, in a patient specific way, solutions to clinical problems. This work focuses on realization of simple simulation scenarios taking into account macroscopic behaviors of stenosis. It means simulating geometrical and physical data from the inflation of a balloon while integrating data from tissues analysis and parameters from virtual tool-tissues interactions. In this context, three main behaviors has been identified: soft tissues crush completely under the effect of the balloon, calcified plaques, do not admit any deformation but could move in deformable structures, the blood vessel wall undergoes consequences from compression phenomenon and tries to find its original form. We investigated the use of Chain-Mail which is based on elements linked with the others thanks to geometric constraints. Compared with time consuming methods or low realism ones, Chain-Mail methods provide a good compromise between physical and geometrical approaches. In this study, constraints are defined from pixel density from angio-CT images. The 2D method, proposed in this paper, first initializes the balloon in the blood vessel lumen. Then the balloon inflates and the moving propagation, gives an approximate reaction of tissues. Finally, a minimal energy level is calculated to locally adjust element positions, throughout elastic relaxation stage. Preliminary experimental results obtained on 2D computed tomography (CT) images (100x100 pixels) show that the method is fast enough to handle a great number of linked-element. The simulation is able to verify real-time and realistic interactions, particularly for hard and soft plaques.

  8. 脉冲电场介导AT2R基因在血管局部表达及其对血管新生内膜的影响%Electroporation-mediated angiotensin Ⅱ type 2 receptor expression improves neo intimal hyperplasia of carotid arteries in rats after balloon angioplasty

    Institute of Scientific and Technical Information of China (English)

    刘德峰; 屈小玲; 刘建平

    2011-01-01

    Objective To determine the effects of electroporation on the transfection of angiotensin Ⅱ type 2 receptor (AT2R) gene into rat carotid arteries and predict its role in neointimal hyperplasia of carotid arteries after balloon angioplasty. Methods After the establishment of rat carotid balloon injury restenosis model, 18 SD rats were divided into AT2R transfection group, empty plasmid transfection group (GFP), and non-transfection group (n = 6 ). AT2R gene plasmid or empty plasmid was transfected by electroporation into rat carotid arteries. Their arteries were harvested at 3, 14 and 21 d after gene transfer, with 2 rats at each time points. The expression of AT2B and morphology of the arteries were evaluated by immunohistochemistry and HE staining respoctively. Results Electroporation-mediated transfection of AT2R gene into injured rat carotid arteries significantly up-regulated the levels of AT2R mRNA in the neointima in a time dependent manner from day 3 to day 14 ( strong to moderate to mild expression). But no expression of AT2B was found in the other 2 groups at these 3 time points. At day 21, AT2R transfection significantly reduced intimal/medial area ratio as compared with non-transfection group and GFP transfection group (0.76 ± 0.08 vs 1.39 ± 0.08 and 1.32 ± 0. 10, P < 0.01 ). No significant difference was found between non-transfection group and GFP transfection group. Conclusion Our results indicate that electroporation is an effective means to introduce naked AT2R DNA into the blood vessel wall, and gene transfer of AT2R in vessel wall may effectively inhibit VSMC proliferation and neointimal hyperplasia in the rat carotid arteries after balloon angioplasty.%目的 研究脉冲电场对血管紧张素2型受体(AT2R)基因在血管局部表达的作用,探讨AT2R基因在体转染对大鼠颈动脉球囊损伤后新生内膜增生的作用.方法 大鼠颈动脉球囊损伤后,用脉冲电穿孔法介导AT2R cDNA真核表达质粒或空质粒载

  9. Use of Reactor-Produced Radioisotopes for Prevention Restenosis After Angioplasty

    International Nuclear Information System (INIS)

    Coronary heart disease leads to myocardial infarction and is a major cause of death in the US. Myocardial infarctions result from atherosclerotic plaque deposits in the coronary arteries, reducing blood flow through these arteries which supply oxygen and nutrients to the heart muscle. The two major approaches for restoring adequate blood flow are coronary bypass graft surgery and coronary angioplasty. Angioplasty is a routinely used clinical procedure, where a deflated balloon attached to the end of a long catheter is inserted into an artery in the leg and then advanced through the aorta into the blocked regions of the coronary arteries. After positioning in the occluded region of the artery, the balloon is inflated with a pressurized saline solution which opens the artery restoring blood flow by pressing the atherosclerotic plaque into the vessel wall. Angioplasty is a widely performed procedure with the coronary arteries and is a much less expensive alternative to coronary bypass surgery. The best patients for angioplasty are those with single occlusions and this method is preferred over bypass grafting because of the significantly reduced expense. The reformation of plaque deposits in arteries (restenosis) following angioplasty, however, is a major clinical problem encountered in as high as 40 percent of patients. Because reduction of health care costs is a major national priority, development of effective new preventative methods for restenoses is an important national priority

  10. Use of Reactor-Produced Radioisotopes for Prevention Restenosis After Angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, F.F.; Pipes, D.W.

    1999-12-21

    Coronary heart disease leads to myocardial infarction and is a major cause of death in the US. Myocardial infarctions result from atherosclerotic plaque deposits in the coronary arteries, reducing blood flow through these arteries which supply oxygen and nutrients to the heart muscle. The two major approaches for restoring adequate blood flow are coronary bypass graft surgery and coronary angioplasty. Angioplasty is a routinely used clinical procedure, where a deflated balloon attached to the end of a long catheter is inserted into an artery in the leg and then advanced through the aorta into the blocked regions of the coronary arteries. After positioning in the occluded region of the artery, the balloon is inflated with a pressurized saline solution which opens the artery restoring blood flow by pressing the atherosclerotic plaque into the vessel wall. Angioplasty is a widely performed procedure with the coronary arteries and is a much less expensive alternative to coronary bypass surgery. The best patients for angioplasty are those with single occlusions and this method is preferred over bypass grafting because of the significantly reduced expense. The reformation of plaque deposits in arteries (restenosis) following angioplasty, however, is a major clinical problem encountered in as high as 40 percent of patients. Because reduction of health care costs is a major national priority, development of effective new preventative methods for restenoses is an important national priority.

  11. Assessment of left ventricular performance during percutaneous transluminal coronary angioplasty: a study by intravenous digital subtraction ventriculography.

    OpenAIRE

    Norell, M. S.; Lyons, J. P.; Gershlick, A H; Gardener, J E; Rothman, M. T.; Layton, C A; Balcon, R

    1988-01-01

    Left ventricular performance during percutaneous transluminal coronary angioplasty was assessed in 52 patients by intravenous digital subtraction ventriculography. After injection of contrast into the right atrium ventriculograms were obtained before and during balloon inflation. In 37 patients they were also obtained after the procedure. A 12 lead electrocardiogram was monitored throughout. During balloon inflation the left ventricular ejection fraction fell (from 73% to 57%) in all but one ...

  12. Percutaneous peripheral laser angioplasty with a pulsed Nd:YAG laser and sapphire tips

    Science.gov (United States)

    Kvasnicka, Jan; Stanek, Frantisek; Boudik, Frantisek; Kubecek, Vaclav; Krivanek, Jiri; Keclik, Richard; Prochazkova, Helena; Hamal, Karel

    1990-07-01

    Percutaneous transluminal laser angioplasty with a pulsed Nd:YAG laser (1,064 nm wavelength, 100 jig pulse duration, up to 0.4 J per pulse, 10 Hz repetition rate) coupled to optical fibers with sapphire tips of 1.8, 2.2 and 2.9 mm diameter was performed in 17 chronic occlusions of iliac, femoral, popliteal and fibular arteries in 15 patients. Clinically the procedure was successful in 14 cases. The probe formed a primary channel of at least 2.0 mm width which was further dilated by conventional balloon catheter. Ankle/brachial systolic pressure index (ABPI) increased from 0.46 0.13 to 0.84 0.21 after the procedure. Two failures were due to an extensive dissection which occurred after balloon angioplasty and resulted in an early reocclusion. In the remaining case a balloon catheter could not be introduced through the 30 cm long primary channel which reoccluded shortly after the recanalization. The initial patency rate was 82 % and in 5 patients followed for more then 6 months the ABPI showed only a minor decrease. These first results are encouraging and it is likely that this method could become an important alternative to conventional balloon angioplasty.

  13. Percutaneous transluminal laser angioplasty

    International Nuclear Information System (INIS)

    In this paper the authors report on a new technique-percutaneous transluminal laser angioplasty (PLR) which was performed on 9 patients with iliac and/or femoro-popliteal artery occlusion. All patients were males (mean age: 64.5 years) and had arterial occlusion (mean lenght: cm 12.5). PLR was performed with an argon laser (max power: 16 Watts). In 8 out of 9 patients (88.8%) a complete recanalization was obtained of the occluded arterial tract, without complications. In one case only (12.2%) there was an arterial wall perforation with unsatisfactory results. In our opinion, PLR has proven a simple methodology, which can be performed on any patient due to the very low incidence of severe complications and distal embolism. Moreover PLR has quite low costs, and does not prevent eventual surgical/percutaneous interventions

  14. Angiotensin Ⅱ type 2 receptor gene mediated by the tetracycline-regulatable system inhibits neointimal hyperplasia in rat carotid arteries after balloon angioplasty%血管紧张素Ⅱ2型受体在体可调控表达对大鼠颈动脉新生内膜增生的影响

    Institute of Scientific and Technical Information of China (English)

    苗莉; 罗先润; 景涛; 张辉; 刘安丰; 娄云霄; 何国祥

    2011-01-01

    Objective Transducing the angiotensin Ⅱ type 2 receptor (AT2R) gene into rat balloon injury carotid arteries can attenuate neointimal hyperplasia, but how to regulate the expression of the AT2.R gene according to our need is very important in utilizing transgenie technology. The purpose of the current study is to investigate the effects of the AT2R gene medicated by the tetracy-cline regulatable system on neointimal hyperplasia in rat carotid arteries after balloon angioplasty. Methods After establishment of the rat model of carotid balloon injury restenosis, we locally perfused into the rat carotid arteries PBS (the control group), mesenchy-mal stem cells (the MSC group) or MSC/AT2R (the MSC/AT2R group) with AT2R medicated by the tetracycline regulatable system, the latter again subdivided into a doxycycline administration (Dox) and non-doxycycline Dox administration (non-Dox) group. At 14 and 28 days after the operation, we evaluated the expression of AT2R by immunohistochemistry and RT-PCR and measured the neointi-ma/media (I/M) area ratio was by morphometric analysis. Results In the MSC/AT2R + Dox group, the expressions of AT2R mRNA and protein in the neointima were significantly up-regulated from day 14 to 28 after injury (P <0.01), and the I/M ratio significantly reduced (P<0.01). The transplanted MSC showed no obvious effect on the neointimal hyperplasia. Conclusion The expression of the AT2R gene can be regulated efficiently in vivo by local delivery of MSC with dual-stable expression of the AT2R gene, and thus inhibit neointimal hyperplasia.%目的 血管紧张素Ⅱ2型受体(angiotensinⅡtype 2 receptor,AT2R)基因转染可减轻血管损伤后新生内膜的过度增生,但如何主动调控转入体内基因的表达有着重要的临床意义.文中以四环素可调控系统下的AT2R基因转染的骨髓间充质干细胞(mesenchymal stem cell,MSC)为载体,探讨AT2R在体可调控表达及对大鼠颈动脉新生内膜的影响.方法 大鼠

  15. Influences on vascular wall smooth muscle cells with novel short-duration thermal angioplasty

    Science.gov (United States)

    Kunio, M.; Shimazaki, N.; Arai, T.; Sakurada, M.

    2012-02-01

    We investigated the influences on smooth muscle cells after our novel short-duration thermal angioplasty, Photo-thermo Dynamic Balloon Angioplasty (PTDBA), to reveal the mechanism that can suppress neo-intimal hyperplasia after PTDBA. We obtained the sufficient arterial dilatations by short-duration heating (angioplasty in vivo. The measured neo-intimal hyperplasia occupancy rate was less than 20% after PTDBA in vivo. We prospect that the inhibition of the growth factor's expression by stretch-fixing may result to suppress the neo-intimal hyperplasia. In addition, the decrease of smooth muscle cells' density in the vessel media by heating might be another reason for the neo-intimal hyperplasia suppression.

  16. Successful Venous Angioplasty of Superior Vena Cava Syndrome after Heart Transplantation

    Directory of Open Access Journals (Sweden)

    Thomas Strecker

    2014-01-01

    Full Text Available Introduction. For patients with terminal heart failure, heart transplantation (HTX has become an established therapy. Before transplantation there are many repeated measurements with a pulmonary artery catheter (PAC via the superior vena cava (SVC necessary. After transplantation, endomyocardial biopsy (EMB is recommended for routine surveillance of heart transplant rejection again through the SVC. Case Presentation. In this report, we present a HTX patient who developed a SVC syndrome as a possible complication of all these procedures via the SVC. This 35-year-old Caucasian male could be successfully treated by balloon dilatation/angioplasty. Conclusion. The SVC syndrome can lead to pressure increase in the venous system such as edema in the head and the upper part of the body and further serious complications like cerebral bleeding and ischemia, or respiratory problems. Balloon angioplasty and stent implantation are valid methods to treat stenoses of the SVC successfully.

  17. The clinical application of percutaneous transluminal balloon angioplasty for hemodialysis patients with stenosis of arteriovenous ifstula%经皮腔内血管成形术在血透患者动静脉内瘘血管狭窄中的应用

    Institute of Scientific and Technical Information of China (English)

    郑尘非; 孙文学; 贾秀芬; 缪克凯; 潘慧君; 刘毅; 黄朝兴

    2015-01-01

    Objective: To report the technical success and long-term clinical outcomes of arteriovenous ifstula (AVF) stenosis after percutaneous transluminal balloon angioplasty (PTA).Methods: A total of 30 patients with stenosis of AVF were enrolled. There were 16 men and 14 women, and the median age was 64.8±13.2 years. Mean time between ifstula creation and intervention was 16.5±13.8 months. The mean duration of hemodialysis time was 31.5±30.2 months. They were examined by digital subtraction angiography (DSA) when they under-went PTA. After the treatment of PTA, all of the patients were examined by 64-multislice spiral computed tomog-raphy angiography every 3 months.Results: The technical success rate was 90.0% in the hemodialysis patients (17 native AVFs and 10 arteriovenous grafts). Primary patency at ifrst, second, third, fourth and iffth three months was 100%, 91.3%, 79.5%, 72.6% and 62.2% respectively. Univariate analysis indicated that there was no signiif-cant correlation between the clinical factors (including age, diabetes mellitus, location, length, grade, and number of stenosis) and primary patency (P>0.05).Conclusion: PTA is an effective treatment method for arteriovenous stenosis, which has high rates of technical success and less complication.%目的:探讨经皮腔内血管成形术(PTA)治疗动静脉内瘘(AVF)狭窄的疗效。方法:回顾性分析30例上肢AVF狭窄患者的临床资料,其中男16例,女14例,平均年龄(64.8±13.2)岁;瘘管平均使用时间(16.5±13.8)月,患者平均透析时间(31.5±30.2)月。所有患者在数字减影血管造影(DSA)下行PTA,术后每3个月经64层螺旋CT血管造影对AVF功能进行评估。结果:本组手术成功率90.0%,其中17例自体AVF和10例人工血管动静脉内瘘(AVG)。术后27例患者首次开通率3个月为100%,6个月为91.3%,9个月为79.5%,12个月为72.6%,15个月为62.2%;术后AVF首次通畅率的单因素Cox风

  18. Angioplasty - Multiple Languages: MedlinePlus

    Science.gov (United States)

    ... Supplements Videos & Tools You Are Here: Home → Multiple Languages → All Health Topics → Angioplasty URL of this page: https://medlineplus.gov/languages/angioplasty.html Other topics A-Z A B ...

  19. [The practical clinical guidelines of the Sociedad Española de Cardiología on interventional cardiology: coronary angioplasty and other technics].

    Science.gov (United States)

    Esplugas, E; Alfonso, F; Alonso, J J; Asín, E; Elizaga, J; Iñiguez, A; Revuelta, J M

    2000-02-01

    Interventional cardiology has had an extraordinary expansion in last years. This clinical guideline is a review of the scientific evidence of the techniques in relation to clinical and anatomic findings. The review includes: 1. Coronary arteriography. 2. Coronary balloon angioplasty. 3. Coronary stents. 4. Other techniques: directional atherectomy, rotational atherectomy, transluminal extraction atherectomy, cutting balloon, laser angioplasty and transmyocardial laser and endovascular radiotherapy. 5. Platelet glycoprotein IIb/IIIa inhibitors. 6. New diagnostic techniques: intravascular ultrasound, coronary angioscopy, Doppler and pressure wire. For the recommendations we have used the classification system: class I, IIa, IIb, III like in the guidelines of the American College of Cardiology and the American Heart Association.

  20. Intravascular optical coherence tomography to characterize tissue deformation during angioplasty: preliminary experiments with artery phantoms

    Science.gov (United States)

    Azarnoush, Hamed; Vergnole, Sébastien; Pazos, Valérie; Bisaillon, Charles-Étienne; Boulet, Benoit; Lamouche, Guy

    2012-09-01

    We explored the potential of intravascular optical coherence tomography (IVOCT) to assess deformation during angioplasty balloon inflation. Using a semi-compliant balloon and artery phantoms, we considered two experimental scenarios. The goal for the first scenario was to investigate if variation in the elasticity of the structure surrounding the balloon could be sensed by IVOCT monitoring. In this scenario, we used three single-layer phantoms with various mechanical properties. Image analysis was performed to extract the inner and outer diameters of the phantoms at various pressures. The goal for the second scenario was twofold. First, we investigated the IVOCT capability to monitor a more complex balloon inflation process. The balloon was in a folded state prior to inflation. This allowed studying two stages of deformation: during balloon unfolding and during balloon expansion. Second, we investigated IVOCT capability to monitor the deformation in a three-layer phantom used to better mimic a true artery. So, not only were the IVOCT images processed to provide the inner and outer diameters of the phantom, but the layer thicknesses were also determined. In both scenarios, IVOCT monitoring revealed to be very efficient in providing relevant information about the phantom deformation during balloon inflation.

  1. Emerging Stent and Balloon Technologies in the Femoropopliteal Arteries

    Directory of Open Access Journals (Sweden)

    Georgios Pastromas

    2014-01-01

    Full Text Available Endovascular procedures for the management of the superficial femoral (SFA and popliteal artery disease are increasingly common. Over the past decade, several stent technologies have been established which may offer new options for improved clinical outcomes. This paper reviews the current evidence for SFA and popliteal artery angioplasty and stenting, with a focus on randomized trials and registries of nitinol self-expanding stents, drug-eluting stents, dug-coated balloons, and covered stent-grafts. We also highlight the limitations of the currently available data and the future routes in peripheral arterial disease (PAD stent and balloon technology.

  2. Primary angioplasty for infarction due to isolated right ventricular artery occlusion

    Institute of Scientific and Technical Information of China (English)

    Anwar; A; Chahal; Min-Young; Kim; Alexander; N; Borg; Yahya; Al-Najjar

    2014-01-01

    We report an unusual case of an isolated right ventricular infarction with haemodynamic compromise caused by spontaneous isolated proximal occlusion of the right ventricular branch of the right coronary artery(RCA), successfully treated by balloon angioplasty. A 58-yearold gentleman presented with epigastric pain radiating into both arms. Electrocardiograph with right ventricular leads confirmed ST elevation in V4 R and a diagnosis of isolated right ventricular infarction was made. Urgent primary percutaneous intervention was performed which revealed occlusion of the right ventricular branch of the RCA. During the procedure, the patient’s blood pressure dropped to 80/40 mm Hg, and echocardiography showed impaired right ventricular systolic function. Despite aggressive fluid resuscitation, the patient remained hypotensive, continued to have chest pain and persistent electrocardiograph changes, and hence balloon angioplasty was performed on the proximal right ventricular branch which restored flow to the vessel and revealed a severe ostial stenosis. This was treated with further balloon angioplasty which restored TIMI 3 flow with resolution of patient’s symptoms. Repeat echocardiography showed complete resolution of theST-elevation in leads V4 R and V5 R and partial resolution in V1. Subsequent dobutamine-stress echocardiography at 4 wk showed good left and right ventricular contractions. The patient was discharged after a 3-d inpatient stay without any complications.

  3. Peripheral Applications of Drug-Coated Balloons: Past, Present and Future

    Energy Technology Data Exchange (ETDEWEB)

    Krokidis, Miltiadis, E-mail: mkrokidis@hotmail.com; Spiliopoulos, Stavros, E-mail: stavspiliop@upatras.gr; Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Sabharwal, Tarun, E-mail: tarun_sabharwal@yahoo.co.uk [Guy' s and St. Thomas' Hospitals, NHS Foundation Trust, Department of Radiology (United Kingdom)

    2013-04-15

    Drug-coated balloon (DCB) technologies represent the latest and hottest development in the field of endovascular treatment of peripheral arterial disease. Initial experience with paclitaxel-coated balloon use in the femoral artery has demonstrated lower mid-term restenosis and superior mid-term clinical outcomes in terms of improved wound healing and reduced repeat angioplasty rates compared with standard balloon angioplasty. Many companies are presently developing and/or improving DCB catheters and therefore ongoing, technical improvements of the already existing platforms, new drugs, and innovative carriers are expected. The ongoing basic research studies and various multicenter randomized, controlled trials that are currently in progress will offer valuable scientific insights regarding the long-term effectiveness and other crucial issues, such as efficacy in various vascular beds, optimal balloon dosage, and post angioplasty antiplatelet therapy. Future applications of these devices also could include in-stent restenosis, anastomotic stenosis of surgical bypass, and benign stenoses of the central venous system. The authors envision that DCB angioplasty will evolve to a major paradigm shift in the endovascular treatment of occlusive vascular diseases.

  4. Randomised comparison of coronary stenting with and without balloon predilatation in selected patients

    OpenAIRE

    Le Breton, H; Boschat, J; Commeau, P; Brunel, P.; Gilard, M; Breut, C; Bar, O.; Geslin, P; Tirouvanziam, A; Maillard, L.; Moquet, B; Barragan, P.; Dupouy, P.; Grollier, G; Berland, J.

    2001-01-01

    BACKGROUND—The SWIBAP (stent without balloon predilatation) prospective randomised trial was designed to compare direct coronary stenting with stenting preceded by lesion predilatation with an angioplasty balloon.
OBJECTIVE—To determine the feasibility and safety of direct stenting in non-complex coronary lesions in a prospective study.
PATIENTS AND DESIGN—All patients  3.0 mm, who granted their informed consent, were randomised into the trial. In group I, the stent was placed without balloon...

  5. Drug-Coated Balloons for Infrainguinal Peripheral Artery Disease.

    Science.gov (United States)

    Sethi, Sanjum S; Lee, Michael S

    2016-07-01

    Revascularization of infrainguinal peripheral artery disease has traditionally been accomplished via percutaneous transluminal angioplasty. However, long-term results have been hampered by high rates of restenosis. Along with the advent of stents, paclitaxel-coated balloons are an emerging therapeutic option for the invasive management of infrainguinal peripheral artery disease. Paclitaxel has been successful in inhibiting neointimal hyperplasia, the main mechanism for in-stent restenosis. Technological advances have facilitated the development of paclitaxel-coated balloons, which show promise in early trials for femoropopliteal stenosis relative to uncoated balloons. For infrapopliteal stenoses, the data remain scant and conflicted. Therefore, large-scale randomized clinical trials with long-term follow-up evaluating safety and effectiveness between various strategies need to be performed to determine the optimal invasive management strategy for infrainguinal peripheral artery disease. PMID:27342205

  6. Heme oxygenase-1 alleviates cigarette smoke-induced restenosis after vascular angioplasty by attenuating inflammation in rat model.

    Science.gov (United States)

    Ni, Leng; Wang, Zhanqi; Yang, Genhuan; Li, Tianjia; Liu, Xinnong; Liu, Changwei

    2016-03-14

    Cigarette smoke is not only a profound independent risk factor of atherosclerosis, but also aggravates restenosis after vascular angioplasty. Heme oxygenase-1 (HO-1) is an endogenous antioxidant and cytoprotective enzyme. In this study, we investigated whether HO-1 upregulating by hemin, a potent HO-1 inducer, can protect against cigarette smoke-induced restenosis in rat's carotid arteries after balloon injury. Results showed that cigarette smoke exposure aggravated stenosis of the lumen, promoted infiltration of inflammatory cells, and induced expression of inflammatory cytokines and adhesion molecules after balloon-induced carotid artery injury. HO-1 upregulating by hemin treatment reduced these effects of cigarette smoke, whereas the beneficial effects were abolished in the presence of Zincprotoporphyrin IX, an HO-1 inhibitor. To conclude, hemin has potential therapeutic applications in the restenosis prevention after the smokers' vascular angioplasty.

  7. Factors influencing acute high-grade restenosis in emergency percutaneous transluminal coronary angioplasty for acute myocardial infarction.

    OpenAIRE

    Kusachi, Shozo; Iwasaki,Kohichirou; Nishiyama, Osamu; Ueda, Minoru; Kita, Toshimasa; Hata,Takato; Taniguchi, Gyou; Watanabe, Hirofumi; Hina, Kazuyoshi; Saito, Daiji; Tsuji, Takao; Haraoka,Shoichi

    1989-01-01

    We studied the factors which may induce acute high grade restenosis in emergency percutaneous transluminal coronary angioplasty (PTCA). PTCA was attempted in 50 patients with acute myocardial infarction, and the balloon catheter passed successfully across the occlusion site in 47 (94%) of the patients. These 47 patients were analyzed. "Acute restenosis" was defined as a lesion which was revascularized to less than 50% luminal reduction narrowed again to more than 75% luminal reduction...

  8. Restenosis following balloon dilation of benign esophageal stenosis

    Institute of Scientific and Technical Information of China (English)

    Ying-Sheng Cheng; Ming-Hua Li; Ren-Jie Yang; Hui-Zhen Zhang; Zai-Xian Ding; Qi-Xin Zhuang; Zhi-Ming Jiang; Ke-Zhong Shang

    2003-01-01

    AIM: To elucidate the mechanism of restenosis following balloon dilation of benign esophageal stenosis.METHODS: A total of 49 rats with esophageal stenosis were induced in 70 rats using 5 ml of 50 % sodium hydroxide solution and the double-balloon method, and an esophageal restenosis (RS) model was developed by esophageal stenosis using dilation of a percutaneous transluminal coronary angioplasty (PTCA) balloon catheter. These 49 rats were divided into two groups: rats with benign esophageal stricture caused by chemical burn only (control group, n=21) and rats with their esophageal stricture treated with balloon catheter dilation (experimental group, n=28). Imaging analysis and immunohistochemistry were used for both quantitative and qualitative analyses of esophageal stenosis and RS formation in the rats, respectively.RESULTS: Cross-sectional areas and perimeters of the esophageal mucosa layer, muscle layer, and the entire esophageal layers increased significantly in the experimental group compared with the control group. Proliferating cell nuclear antigen (PCNA) was expressed on the 5th day after dilation, and was still present at 1 month. Fibronectin (FN)was expressed on the 1st day after dilation, and was still present at 1 month.CONCLUSION: Expression of PCNA and FN plays an important role in RS after balloon dilation of benign esophageal stenosis.

  9. Below-the-ankle Angioplasty and Stenting for Limb Salvage: Anatomical Considerations and Long-term Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Diamantopoulos, Athanasios; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris [School of Medicine, Patras University Hospital, Department of Interventional Radiology (Greece)

    2013-08-01

    PurposeTo report the long-term angiographic and clinical results in a series of below-the-ankle (BTA) angioplasty procedures and to present some biomechanical issues related to the unique anatomical geometry of the ankle.MethodsWe performed a retrospective analysis of BTA angioplasty procedures. Clinical end points included technical success, patient mortality, salvage of the treated foot, and repeat target lesion revascularization. Imaging end points included primary patency, binary restenosis of the target lesion at the 50 % threshold, and stent integrity (stent fracture, deformation, or collapse). Univariate subgroup analysis was performed.ResultsIn total, 40 limbs in 37 patients (age 73.5 {+-} 8.2 years) with critical limb ischemia were included and 42 inframalleolar lesions (4.2 {+-} 1.4 cm) were analyzed. Technical success was achieved in 95.2 % (40 of 42). Provisional stent placement was performed in 45.2 % (19 of 42). Two patients died, and two major amputations occurred up to 3 years. At 1 year, overall primary vessel patency was 50.4 {+-} 9.1 %, lesion binary restenosis rate was 64.1 {+-} 8.3 %, and repeat intervention-free survival was 93.6 {+-} 4.3 % according to life table analysis of all treated lesions. Pairwise subgroup analysis showed that BTA self-expanding stents were associated with significantly higher restenosis and poorer primary patency compared to plain balloon angioplasty or sirolimus-eluting balloon-expandable stents. Significant deformation and/or fracture of balloon-expandable stents placed BTA were identified in five of 11. Dynamic imaging showed that the dorsalis pedis artery is kinked during foot dorsiflexion, whereas the distal posterior tibial artery is kinked during plantar flexion of the foot.ConclusionBTA angioplasty for critical limb ischemia treatment is safe and feasible with satisfactory long-term results. BTA stent placement must be reserved for bailout indications.

  10. Carotid angioplasty with cerebral protection

    International Nuclear Information System (INIS)

    Background. Carotid endarterectomy (CEA) is widely used in the management of high-grade carotid stenosis. It is a surgical procedure requiring general anaesthesia and is suitable only for lesions located at or close to the carotid bifurcation. It may develop complications, such as stroke, death, cranial nerve palsies, wound haematoma and cardiac complications. The risk of complications is increased in patients with recurrent carotid artery stenosis following CEA, in subjects undergoing radiotherapy to the neck, and in patients with cardiopulmonary disease. The drawbacks of CEA have led physicians to search for alternative treatment options. Carotid angioplasty and stenting (CAS) is less invasive than CEA. The method is particularly suitable for the treatment of recurrent stenosis after previous CEA and distal internal artery stenosis, which is inaccessible for CEA. CAS does not cause cranial nerve palsies. Moreover, it does not require general anaesthesia and causes lower morbidity and mortality in patients with severe cardiopulmonary disease. The complications of CAS include stroke due to distal immobilisation of a plaque or thrombus dislodged during the procedure, abrupt vessel occlusion due to thrombosis, dissection or vasospasm, and restenosis due to intimal hyperplasia. CAS is a relatively new procedure; therefore, it is essential to establish its efficacy and safety before it is introduced widely into clinical practice. Patients and methods. In Slovenia, we have also started with carotid angioplasty by the study: Slovenian Carotid Angioplasty Study (SCAS). We performed CAS in 17 patients (12 males and 5 females) aged from 69 to 82 years. All patients were symptomatic with stenosis greater than 70 %. 10 patients suffered transient ischemic attacks, 4 patients minor strokes and 3 patients amaurosis fugax. Results. Technical success (< 30 % residual stenosis) was achieved in all cases. In 14 patients, no residual stenosis was found, in 2 patients a 15 % residual

  11. Sleep Apnea Tied to Complications After Angioplasty

    Science.gov (United States)

    ... page: https://medlineplus.gov/news/fullstory_159391.html Sleep Apnea Tied to Complications After Angioplasty Nightly breathing ... 15, 2016 WEDNESDAY, June 15, 2016 (HealthDay News) -- Sleep apnea may increase the risk of serious complications ...

  12. Emergency surgical revascularisation for coronary angioplasty complications.

    OpenAIRE

    Carey, J A; Davies, S W; Balcon, R.; Layton, C.; Magee, P; Rothman, M. T.; Timmis, A. D.; Wright, J. E.; Walesby, R K

    1994-01-01

    OBJECTIVES--To evaluate trends in referrals for emergency operations after percutaneous transluminal coronary angioplasty (PTCA) complications; to analyse morbidity and mortality and assess the influence of PTCA backup on elective surgery. DESIGN--A retrospective analysis of patients requiring emergency surgical revascularisation within 24 hours of percutaneous transluminal coronary angioplasty. PATIENTS--Between January 1980 and December 1990, 75 patients requiring emergency surgery within 2...

  13. GHOST balloons around Antarctica

    Science.gov (United States)

    Stearns, Charles R.

    1988-01-01

    The GHOST balloon position as a function of time data shows that the atmospheric circulation around the Antarctic Continent at the 100 mb and 200 mb levels is complex. The GHOST balloons supposedly follow the horizontal trajectory of the air at the balloon level. The position of GHOST balloon 98Q for a three month period in 1968 is shown. The balloon moved to within 2 deg of the South Pole on 1 October 1968 and then by 9 December 1968 was 35 deg from the South Pole and close to its position on 1 September 1968. The balloon generally moved from west to east but on two occasions moved in the opposite direction for a few days. The latitude of GHOST balloons 98Q and 149Z which was at 200 mb is given. Both balloons tended to get closer to the South Pole in September and October. Other GHOST balloons at the same pressure and time period may not indicate similar behavior.

  14. Weather Balloon Ascent Rate

    Science.gov (United States)

    Denny, Mark

    2016-05-01

    The physics of a weather balloon is analyzed. The surprising aspect of the motion of these balloons is that they ascend to great altitudes (typically 35 km) at a more or less constant rate. Such behavior is not surprising near the ground—say for a helium-filled party balloon rising from street level to the top of the Empire State building—but it is unexpected for a balloon that rises to altitudes where the air is rarefied. We show from elementary physical laws why the ascent rate is approximately constant.

  15. The Application of Dual-wire Balloon in The Treatment of Coronary Bifurcation Lesions

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Objectives To assess the efficiency and safety of dual-wire balloon angioplasty side branch combined stenting the main branch in the treatment of coronary bifurcation lesions. Methods This study included thirty-six patients with 41 coronary bifurcation lesions. Selective dual-wire balloon angioplasty was performed in side branch and/or in main branch, and implantation of stents was performed in main branch only. Clinical outcome and major adverse cardiac events were observed inhospital and follow-up. Results Success rate of side branch dilatation before main branch stenting was 100%; main branch direct stenting performed in 4 cases; success main branch dilatation performed in the other 37 cases; kissing technique was performed successfully in 5 cases, which side branch was jailed after main branch stenting with TIMI grade 0-2 flow. No Q-wave myocardial infarction, acute revascularization and death occurred during in-hospital.Clinical follow-up was available in all patients. No Q-wave myocardial infarction, revascularization and death occurred, angina pectoris recurred in three patients,released by strengthen drug treatment. Conclusions Dual-wire balloon angioplasty side branch combined stenting the main branch is simple, safe and effective for the treatment of coronary bifurcation lesions.

  16. Clefting in pumpkin balloons

    Science.gov (United States)

    Baginski, F.; Schur, W.

    NASA's effort to develop a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, focuses on a pumpkin shape super-pressure design. It has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired stable state instead. Hoop stress considerations in the pumpkin design leads to choosing the lowest possible bulge radius, while robust deployment is favored by a large bulge radius. Some qualitative understanding of design aspects on undesired equilibria in pumpkin balloons has been obtained via small-scale balloon testing. Poorly deploying balloons have clefts, but most gores away from the cleft deploy uniformly. In this paper, we present models for pumpkin balloons with clefts. Long term success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and means for quantitative assessment of measures that prevent their occurrence. This paper attempts to determine numerical thresholds of design parameters that distinguish between properly deploying designs and improperly deploying designs by analytically investigating designs in the vicinity of criticality. Design elements which may trigger the onset undesired equilibria and remedial measures that ensure deployment are discussed.

  17. Roles of thrombin and platelet membrane glycoprotein IIb/IIIa in platelet-subendothelial deposition after angioplasty in an ex vivo whole artery model

    International Nuclear Information System (INIS)

    Platelet deposition at the site of injury caused by balloon angioplasty is associated with acute closure and restenosis. In a new ex vivo whole artery angioplasty model, the authors examined the roles of thrombin inhibition with D-Phe-Pro-ArgCH2Cl (PPACK) and inhibition of the platelet membrane fibrinogen receptor glycoprotein IIb/IIIa (GPIIb/IIIa) with monoclonal antibody 7E3 on platelet deposition at the site of balloon injury. Fresh rabbit aortas were mounted in a perfusion chamber. One half of the mounted arterial segment was dilated with a standard angioplasty balloon catheter and the uninjured half served as the control segment. The vessels were perfused with human blood at physiological pressure and shear rates of 180-250 second-1 for 30 minutes. Platelet deposition was measured using 111In-labeled platelets and scanning electron microscopy. With heparin (2 units/ml) anticoagulation, 8.2 ± 2.2 x 10(6) platelets/cm2 were deposited at the site of balloon injury compared with 0.7 ± 0.2 x 10(6) platelets/cm2 on uninjured segments (p less than 0.02, n = 7). PPACK was tested at a concentration (10 microM) that totally inhibited platelet aggregation in response to thrombin. 7E3 was tested at a concentration (10 micrograms/ml) that totally inhibited platelet aggregation. Platelet deposition at the site of balloon injury was reduced 47% by PPACK and 70% by 7E3 compared with heparin. At shear rates seen in nonstenotic coronary arteries, PPACK and 7E3 are more effective than heparin in reducing platelet deposition at the site of balloon injury. The significant inhibition of platelet deposition by PPACK demonstrates the importance of heparin-resistant thrombin in platelet thrombus formation

  18. Effect of percutaneous transluminal angioplasty on the stenosis of autogenous radiocephalic ateriovenous fistula for hemodialysis

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Sun Min; Kim, Jeong Ho; Byun, Sung Su; Kang, Jin MMo; Choi, Sang Tae; Kim, Jong Woo; Kim, Hyung Sik; Choi, Hye Young [Gachon University Gil Medical Center, Incheon (Korea, Republic of); Park, Jae Hyung [Dept. of Radiology, Seonam University College of Medicine, Myongji Hospital, Goyang (Korea, Republic of)

    2016-02-15

    The purpose of this study was to evaluate the effectiveness of percutaneous transluminal angioplasty (PTA) on stenosis of autogenous radiocephalic arteriovenous fistula (RCF) for hemodialysis and to determine the factors influencing patency. This retrospective study included 136 patients referred for PTA of RCF stenosis between March 2005 and July 2014. The technical success rate, complications, and patency rate were evaluated. The following factors were analyzed as they might influence patency: age, gender, site and duration of arteriovenous fistula, underlying disease, body mass index, hypercholesterolemia, smoking, peripheral artery or coronary artery occlusive disease, stenosis length/grade, cutting balloon, and balloon size. The initial technical success rate was 91.9% (125/136). Complications included vessel rupture (n = 2) and vessel dissection (n = 2). The patency rates at 6, 12, 24, and 48 months after PTA were 81.9, 67.1, 52.7, and 42.3%, respectively. The patency rate was higher in cases with longer (> 3 cm) stenosis (p = 0.04). Use of cutting balloon and larger size of balloon catheter made the patency longer, but this difference was not statistically significant (p = 0.637, 0.258). PTA is a safe and effective way to manage stenosis in RCF. The length of stenosis was the only factor which affected the patency rate in this study.

  19. Role of interferon-γ on smooth muscle cells proliferation and migration after balloon injury by inhibiting transforming growth factor-β signal pathway

    Institute of Scientific and Technical Information of China (English)

    MEI Yu; WANG Gui-zhao; HUANG Yong-lin

    2003-01-01

    @@ Objective Restenosis after balloon angioplasty resuits from abnormal proliferation of phenotypically modulated vascular smooth muscle cells (SMCs) that migrate and synthesize large amounts of extracellular matrix. A vafety of growth factors have been shown to play a role in the development of restenotic lesions including transforming growth factor-β (TGF-β).

  20. Bursting water balloons

    CERN Document Server

    Lund, Hugh M

    2011-01-01

    The impact and rupture of water-filled balloons upon a flat, rigid surface is studied experimentally, for which three distinct stages of the flow are observed. Due to the impact, waves are formed on the balloon's surface for which the restoring force is tension in the latex. Immediately following rupture of the membrane, a shear instability created by the retraction of the balloon is observed. At later times, a larger-scale growth of the interfacial amplitude is observed, that may be regarded as a manifestation of a phenomenon known as the Richtmyer-Meshkov instability. This flow is closely related to the classical understanding of the Richtmyer-Meshkov instability for when there exists a density difference between the fluids inside and outside the balloon. Further, it is shown experimentally that this growth of the interface may also occur when there is no density difference across the balloon, a situation that does not arise for the standard Richtmyer-Meshkov instability.

  1. Balloon dacryocystoplasty study in the management of adult epiphora.

    LENUS (Irish Health Repository)

    Fenton, S

    2012-02-03

    PURPOSE: To determine the efficacy of dacryocystoplasty with balloon dilation in the treatment of acquired obstruction of the nasolacrimal system in adults. METHODS: Balloon dacryocystoplasty was performed in 52 eyes of 42 patients under general anaesthetic. A Teflon-coated guidewire was introduced through the canaliculus and manipulated through the nasolacrimal system and out of the nasal aperture. A 4 mm wide 3 cm coronary angioplasty balloon catheter was threaded over the guidewire in a retrograde fashion and dilated at the site of obstruction. RESULTS: There was complete obstruction in 30% of cases and partial obstruction in 70%. The most common site of obstruction was the nasolacrimal duct. The procedure was technically successful in 94% of cases. The overall re-obstruction rate was 29% within 1 year of the procedure. There was an anatomical failure rate of 17% for partial obstruction and 69% for complete obstruction within 1 year. CONCLUSIONS: Balloon dacryocystoplasty has a high recurrence rate. There may be a limited role for this procedure in partial obstructions. Further refinements of the procedure are necessary before it can be offered as a comparable alternative to a standard surgical dacryocystorhinostomy.

  2. The usefulness of wire-loop technique for percutaneous angioplasty of insufficient hemodialysis fistula

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Hun; Goo, Dong Erk; Kim, Dae Ho; Choi, Deuk Lin; Moon, Chul [College of Medicine, Soonchunhyang University, Seoul (Korea, Republic of)

    2000-10-01

    To evaluate the usefulness of the wire-loop technique, used to perform percutaneous transluminal angioplasty (PTA) in occluded arteriovenous fistula when standard methods fail to pass the balloon catheter across the stenotic segment. In 30 patients (M:F = 14:16; aged 27-77 (mean, 51.3) years), the Wire-Loop technique was used to perform percutaneous transluminal angioplasty of insufficiently hemodialysed arteriovenous fistula where a balloon catheter had failed to pass through the stenotic lesion after a guide wire had successfully passed. Native and Gore-tex fistula were used in 22 and eight cases, respectively.Sixteen stenoses were located in the central vein, and fourteen in the peripheral. The puncture sites used in order to perform the technique were the femoral vein in all cases of central stenosis; three basilic, four cephalic, and five femoral veins in cases of peripheral stenosis and one femoral and one radial artery in cases of anastomotic stenosis. The guide wire was passed through the stenotic lesion, pulled out using the snare technique, and then stretched in order to tighten it. The balloon catheter was then passed through the lesion and traditional balloon angioplasty was performed. The technical success rate and complications of the technique, and the patency rate of recanalized arteriovenous fistula, were evaluated. In 26 of the thirty patients, (86.7%), the procedure was technically successful. In the remaining four cases, failure was due to venous dissection (n=1), marked residual stenosis (n=2), or cardiac arrest (n=1) during the procedure. The average procedure time was 105 (range, 40-210) minutes, and in three cases rupture of the vein occurred. The patency rate of PTA was 80% (24/30) at four months, 63% (19/30) at six months, and 30% (9/30) at twelve months. The expected technical success rate of traditional PTA, without the Wire-Loop technique, would have been 79.3%, but using the technique, the rate increased to 86.7%. The Wire

  3. Balloon Design Software

    Science.gov (United States)

    Farley, Rodger

    2007-01-01

    PlanetaryBalloon Version 5.0 is a software package for the design of meridionally lobed planetary balloons. It operates in a Windows environment, and programming was done in Visual Basic 6. By including the effects of circular lobes with load tapes, skin mass, hoop and meridional stress, and elasticity in the structural elements, a more accurate balloon shape of practical construction can be determined as well as the room-temperature cut pattern for the gore shapes. The computer algorithm is formulated for sizing meridionally lobed balloons for any generalized atmosphere or planet. This also covers zero-pressure, over-pressure, and super-pressure balloons. Low circumferential loads with meridionally reinforced load tapes will produce shapes close to what are known as the "natural shape." The software allows for the design of constant angle, constant radius, or constant hoop stress balloons. It uses the desired payload capacity for given atmospheric conditions and determines the required volume, allowing users to design exactly to their requirements. The formulations are generalized to use any lift gas (or mixture of gases), any atmosphere, or any planet as described by the local acceleration of gravity. PlanetaryBalloon software has a comprehensive user manual that covers features ranging from, but not limited to, buoyancy and super-pressure, convenient design equations, shape formulation, and orthotropic stress/strain.

  4. Holmium:YAG laser angioplasty: treatment of acute myocardial infarction

    Science.gov (United States)

    Topaz, On

    1993-06-01

    We report our clinical experience with a group of 14 patients who presented with acute myocardial infarction. A holmium:YAG laser was applied to the infarct-related artery. This laser emits 250 - 600 mJ per pulse, with a pulse length of 250 microseconds and repetition rate of 5 Hz. Potential benefits of acute thrombolysis by lasers include the absence of systemic lytic state; a shortened thrombus clearing time relative to using thrombolytics; safe removal of the intracoronary thrombus and facilitation of adjunct balloon angioplasty. Potential clinical difficulties include targeting the obstructive clot and plaque, creation of debris and distal emboli and laser-tissue damage. It is conceivable that holmium:YAG laser can be a successful thrombolytic device as its wave length (2.1 microns) coincides with strong water absorption peaks. Since it is common to find an atherosclerotic plaque located under or distal to the thrombotic occlusion, this laser can also be applied for plaque ablation, and the patient presenting with acute myocardial infarction can clearly benefit from the combined function of this laser system.

  5. Transluminal angioplasty, fibrinolysis, and newer vascular interventions

    International Nuclear Information System (INIS)

    This refresher course presents an overview of the current status of transluminal angioplasty in the treatment of peripheral vascular disease, renovascular hypertension, and upper extremity vasculature. Indications for therapy, accepted techniques, and the diagnosis and treatment of complications are major topic areas. Newer areas of increasing application are discussed, particularly popliteal and tibial angioplasty. Newer devices and procedures such as lasers, percutaneous atherectomy, and mechanical recanalization devices are reviewed and their role in the current therapeutic armamentarium discussed. The current status of catheter-directed fibrinolytic techniques is presented, particularly as they relate to the concomitant use of transluminal angioplasty. The choice of lytic agents and newer agents is reviewed. Long-term results and complication rates are discussed by anatomic area

  6. [Subintimal angioplasty and diabetic foot revascularisation].

    Science.gov (United States)

    Pierret, Charles; Tourtier, Jean-Pierre; Bordier, Lise; Blin, Emmanuel; Duverger, Vincent

    2011-01-01

    Diabetic wounds foot are responsible for 5-10% minor or major amputation in France. In fact, amputation risk of lower limbs is 15-30% higher for diabetic patients. University of Texas classification (UT) is the reference for diabetic foot wound. It distinguish non ischemic and ischemic wound with more amputation. If ischaemia is combined, revascularization may be considered for salvage of the limb. Some revascularization techniques are well known: as surgical by-pass, angioplasty with or without stent, or hybrid procedures with the both. Subintimal angioplasty is a more recent endovascular technique, in assessment for old patients who are believed to be unsuitable candidates for conventional by-pass or angioplasty.

  7. The Descending Helium Balloon

    Science.gov (United States)

    Helseth, Lars Egil

    2014-01-01

    I describe a simple and fascinating experiment wherein helium leaks out of a rubber balloon, thereby causing it to descend. An estimate of the volumetric leakage rate is made by measuring its rate of descent.

  8. Laser-driven short-duration heating angioplasty: chronic artery lumen patency and histology in porcine iliac artery

    Science.gov (United States)

    Shimazaki, Natsumi; Kunio, Mie; Naruse, Sho; Arai, Tsunenori; Sakurada, Masami

    2012-02-01

    We proposed a short-duration heating balloon angioplasty. We designed a prototype short-duration heating balloon catheter that can heat artery media to 60-70°C within 15-25 s with a combination of laser-driven heat generation and continuous fluid irrigation in the balloon. The purpose of this study was to investigate chronic artery lumen patency as well as histological alteration of artery wall after the short-duration heating balloon dilatation with porcine healthy iliac artery. The short-term heating balloon dilated sites were angiographically patent in acute (1 hour) and in chronic phases (1 and 4 weeks). One week after the dilatation, smooth muscle cells (SMCs) density in the artery media measured from H&E-stained specimens was approx. 20% lower than that in the reference artery. One and four weeks after the dilatations, normal structure of artery adventitia was maintained without any incidence of thermal injury. Normal lamellar structure of the artery media was also maintained. We found that the localized heating restricted to artery media by the short-duration heating could maintain adventitial function and artery normal structure in chronic phase.

  9. New developments in the clinical use of drug-coated balloon catheters in peripheral arterial disease

    Science.gov (United States)

    Naghi, Jesse; Yalvac, Ethan A; Pourdjabbar, Ali; Ang, Lawrence; Bahadorani, John; Reeves, Ryan R; Mahmud, Ehtisham; Patel, Mitul

    2016-01-01

    Peripheral arterial disease (PAD) involving the lower extremity is a major source of morbidity and mortality. Clinical manifestations of PAD span the spectrum from lifestyle limiting claudication to ulceration and gangrene leading to amputation. Advancements including balloon angioplasty, self-expanding stents, drug-eluting stents, and atherectomy have resulted in high technical success rates for endovascular therapy in patients with PAD. However, these advances have been limited by somewhat high rates of clinical restenosis and clinically driven target lesion revascularization. The recent introduction of drug-coated balloon technology shows promise in limiting neointimal hyperplasia induced by vascular injury after endovascular therapies. This review summarizes the contemporary clinical data in the emerging area of drug-coated balloons.

  10. Coronary angioplasty for early postinfarction unstable angina

    NARCIS (Netherlands)

    P.J. de Feyter (Pim); P.W.J.C. Serruys (Patrick); A. Soward; M.J.B.M. van den Brand (Marcel); E. Bos (Egbert); P.G. Hugenholtz (Paul)

    1986-01-01

    textabstractCoronary angioplasty was performed in 53 patients in whom unstable angina had reoccurred after 48 hr and within 30 days after sustained myocardial infarction. Single-vessel disease was present in 64% of the patients and multivessel disease in 36%. The preceding myocardial infarction had

  11. Primary coronary angioplasty in acute myocardial infarction.

    OpenAIRE

    Grech, E. D.; Ramsdale, D. R.

    1996-01-01

    It is well established that recanalisation of the infarct-related artery is of great benefit in the early hours after acute myocardial infarction. This can be achieved by the use of thrombolytic agents and/or by percutaneous transluminal coronary angioplasty (PTCA). This article reviews data on the role of primary PTCA and summarises current opinion on its use.

  12. Intervention with rotational atherectomy, sharp balloon and implant of conventional Stent in ostium lesion of right coronary artery, calcified

    International Nuclear Information System (INIS)

    Atherosclerotic lesions from the right coronary artery ostium have a low incidence in the manifestation of coronary disease. The high content of smooth muscle cells in the coronary ostium is related to a low success probability of a percutaneous intervention. We present a clinical complex case of a 61 years old female with right coronary artery ostium disease to whom we performed an angioplasty with cutting balloon and rotational arterectomy with successful results

  13. Universal stratospheric balloon gradiometer

    Science.gov (United States)

    Tsvetkov, Yury; Filippov, Sergey; Brekhov, Oleg; Nikolaev, Nikolay

    The study of the interior structure of the Earth and laws of its evolution is one of the most difficult problems of natural science. Among the geophysical fields the anomaly magnetic field is one of the most informational in questions of the Earth’s crust structure. Many important parameters of an environment are expedient for measuring at lower altitudes, than satellite ones. So, one of the alternatives is stratospheric balloon survey. The balloon flight altitudes cover the range from 20 to 50 km. At such altitudes there are steady zone air flows due to which the balloon flight trajectories can be of any direction, including round-the-world (round-the-pole). For investigation of Earth's magnetic field one of the examples of such sounding system have been designed, developed and maintained at IZMIRAN and MAI during already about 25 years. This system consists of three instrumental containers uniformly placed along a vertical 6 km line. Up today this set has been used only for geomagnetic purposes. So we describe this system on example of the measuring of the geomagnetic field gradient. System allows measuring a module and vertical gradient of the geomagnetic field along the whole flight trajectory and so one’s name is - stratospheric balloon magnetic gradiometer (SMBG). The GPS-receivers, located in each instrumental container, fix the flight coordinates to within several tens meters. Process of SBMG deployment, feature of the exit of rope from the magazine at the moment of balloon launching has been studied. Used magazine is cellular type. The hodograph of the measuring base of SBMG and the technique of correction of the deviations of the measuring base from the vertical line (introduction of the amendments for the deviation) during the flight have been investigated. It is shown that estimation of the normal level of values of the vertical gradient of the geomagnetic field is determined by the accuracy of determining the length of the measuring base SBMG

  14. Mars Solar Balloon Lander Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Solar Balloon Lander (MSBL) is a novel concept which utilizes the capability of solar-heated hot air balloons to perform soft landings of scientific...

  15. Venus Altitude Cycling Balloon Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The ISTAR Group ( IG) and team mate Thin Red Line Aerospace (TRLA) propose a Venus altitude cycling balloon (Venus ACB), an innovative superpressure balloon...

  16. JACEE long duration balloon flights

    International Nuclear Information System (INIS)

    JACEE balloon-borne emulsion chamber detectors are used to observe the spectra and interactions of cosmic ray protons and nuclei in the energy range 1-100A TeV. Experience with long duration mid-latitude balloon flights and characteristics of the detector system that make it ideal for planned Antarctic balloon flights are discussed. 5 refs., 2 figs

  17. Short and long term outcomes of primary angioplasty in patients aged 75 years and over

    Directory of Open Access Journals (Sweden)

    Turgay Işık

    2011-06-01

    Full Text Available The treatment of elderly patients with ST segment elevated myocardial infarction (STEMI remains controversial. This study aimed to investigate the effects of primary angioplasty in elderly patients on in-hospital and long term major adverse cardiac events (MACE.Materials and methods: From October 2003 to March 2008, we retrospectively enrolled 220 patients aged 75 years and over with STEMI who underwent primary angioplasty. Patients’ characteristics, in-hospital and long term events were recorded.Results: Male/Female ratio of patients was 129/91 and mean age was 78.7 ± 3.6 (range, 75-97 years, and 58.6% of male. Of these patients 29.2% were diabetics, 69.8% were hypertensive, 34.4% were smoker and 43.5% were anemic at admission. Anterior myocardial infarction was diagnosed in 52.3% of patients. Mean pain-balloon time was 222 ± 116 minutes. Eighty two (38.2% of these 220 patients had three-vessel disease and 12 (5.7% were diagnosed as cardiogenic shock. Procedural success was observed in 79.6% of patients. Heart failure was observed 27.7% in hospital and intra aortic pump was used in 14.5% of patients. There was no significant difference between age groups in long term major cardiac events and in hospital mortality. Diabetes, leukocyte count at admission and in hospital heart failure were independent predictors of short term MACE and low hemoglobin level at admission and peak CKMB levels were independent predictors of long term MACE.Conclusions: Primary angioplasty in patients aged 75 years and over seems to be associated with low procedural complication, high procedural success, improved short and long term survival.

  18. Peripheral macroembolism complicating laser angioplasty of arteries of extremities - therapy with radiologic interventional methods

    International Nuclear Information System (INIS)

    From 1987 to 1989 in the Barmherzige Brueder Hospital in Linz/Austria 160 arteries of extremities were treated with laser-assisted balloon dilatation. During these interventions peripheral macroembolism occurred 8 times. The mean length of the recanalised segment was 8.7 cm and thus longer than average (6.5 cm). All 8 cases were successfully treated by aspiration or aspiration combined with local lysis. No adverse effects on long-term results were noted. In 4 cases an early occlusion of the recanalised segment was diagnosed within 48 hours after laser-assisted angioplasty, three times accompanied by embolism. These emboli, too, were removed by aspriation and lysis. To reduce the risk of embolisation strict rules of indication concerning the age of an occlusion have to be observed and mechanical trauma has to be minimised. (orig.)

  19. Percutaneous Transluminal Coronary Angioplasty after Cardiac Transplantation

    OpenAIRE

    Avedissian, Michael G.; Bush, Howard S; Leachman, D. Richard; Fighali, Sayid; Frazier, O. H.

    1989-01-01

    This report describes the 1st use of percutaneous transluminal coronary angioplasty in a posttransplant patient at the Texas Heart Institute. The patient, a 44-year-old man, experienced 3 episodes of moderate allograft rejection, hypercholesterolemia, transient severe hyperglycemia, and transient severe renal insufficiency in the posttransplant period. His cholesterol levels became elevated immediately and remained between 200 and 250 mg/dL, despite treatment with gemfibrozil. He had increasi...

  20. Ballon angioplasty and stenting for acute ischemic stroke%急性缺血性卒中患者的球囊血管成形和支架置入术治疗

    Institute of Scientific and Technical Information of China (English)

    石明超; 王守春

    2009-01-01

    药物溶栓治疗急性缺血性卒中存在一定的局限性,球囊血管成形和支架置入术已成为急性缺血性卒中治疗的研究热点.文章综述了球囊血管成形和支架置入术治疗急性缺血性卒中的有效性和安全性.%Thrombolytic agents for the treatment of acute ischemic stroke have some limitations. Balloon angioplasty and stenting have become the research hotspot in the treatment of acute ischemic stroke. 1his article reviews the effectiveness and safety of balloon angioplasty and stenting in the treatment of acute ischemic stroke.

  1. How does subintimal angioplasty compare to transluminal angioplasty for the treatment of femoral occlusive disease?

    Science.gov (United States)

    Klimach, S G; Gollop, N D; Ellis, J; Cathcart, P

    2014-01-01

    A best evidence topic in surgery was written according to a structured protocol. The question addressed how subintimal angioplasty (SIA) compares to transluminal angioplasty (TA) for the treatment of femoral occlusive disease. One hundred and thirty two papers were found using the reported search; the 5 which represented the best evidence to answer the question are discussed. The evidence on this subject is limited; there are no randomised controlled trials (RCTs) comparing SIA to TA for pathologically equivalent lesions. However SIA remains a safe and effective alternative to surgical bypass grafting when TA cannot be performed.

  2. Critical limb ischaemia in a diabetic population from an Asian Centre: angiographic pattern of disease and 3-year limb salvage rate with percutaneous angioplasty as first line of treatment

    OpenAIRE

    Tan, M; Pua, U; Wong, DES; Punamiya, SJ; Chua, GC; Teo, N

    2010-01-01

    Purpose: Lower extremity amputation prevention (LEAP) is an ongoing program in our institution aimed at salvaging limbs in patients with critical limb ischemia (CLI). Patients in the LEAP program with reconstructible anatomy on initial Doppler imaging received either bypass surgery or percutaneous transluminal balloon angioplasty (PTA). We present the 3 year limb salvage rate and angiographic disease patterns in 42 consecutive diabetic patients with CLI who received PTA in 2005. Methods and M...

  3. Percutaneous transluminal coronary angioplasty for culprit lesions in patients with post myocardial infarction angina based on dextrocardia and anomalous coronary arteries. Case reports and methods.

    Science.gov (United States)

    Yabe, Y; Tsukahara, R

    1995-05-01

    Four cases of successful coronary angioplasty for anomalous coronary arteries, including dextrocardia associated with three-vessel disease, single left coronary artery with proximal left anterior descending lesion, anomalous right coronary artery (RCA) from adjacent left coronary sinus of Valsalva associated with proximal RCA lesion, and anomalous left circumflex angulated lesion bifurcated from the RCA, were encountered. Four cases with 8 target lesions who had a mean age of 63.5 +/- 11.5 years old are presented. All the targets lesions were completely dilated through balloon angioplasty, including use of a newly developed support device for cases with large jeopardized myocardium. The factors for complete revascularization were appropriate selection of catheters and originality and ingenuity of procedural technique based on the anatomic characteristics.

  4. Prevention of Intracranial In-stent Restenoses: Predilatation with a Drug Eluting Balloon, Followed by the Deployment of a Self-Expanding Stent

    Energy Technology Data Exchange (ETDEWEB)

    Vajda, Zsolt, E-mail: Z.Vajda@klinikum-stuttgart.de; Guethe, Thomas, E-mail: T.Guethe@klinikum-stuttgart.de; Perez, Marta Aguilar, E-mail: M.Aguilar@klinikum-stuttgart.de; Kurre, Wiebke, E-mail: w.kurre@klinikum-stuttgart.de [Klinikum Stuttgart, Katharinenhospital, Klinik fuer Neuroradiologie, Neurozentrum (Germany); Schmid, Elisabeth, E-mail: ESchmid@klinikum-stuttgart.de; Baezner, Hansjoerg, E-mail: H.Baezner@klinikum-stuttgart.de [Klinikum Stuttgart, Klinik fuer Neurologie, Neurozentrum (Germany); Henkes, Hans, E-mail: hhhenkes@aol.com [Klinikum Stuttgart, Katharinenhospital, Klinik fuer Neuroradiologie, Neurozentrum (Germany)

    2013-04-15

    Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54-86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followed by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.

  5. High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction

    Science.gov (United States)

    Huang, Ching-Hui; Kuo, Chen-Ling; Huang, Ching-Shan; Tseng, Wan-Min; Lian, Ie Bin; Chang, Chia-Chu; Liu, Chin-San

    2016-01-01

    Abstract Exogenous administration of coenzyme Q10 (CoQ10) has been shown in experimental models to have a protective effect against ischemia–reperfusion injury. However, it is unclear whether follow-up plasma CoQ10 concentration is prognostic of left ventricular (LV) performance after primary balloon angioplasty in patients with acute ST segment elevation myocardial infarction (STEMI). We prospectively recruited 55 patients with STEMI who were treated with primary coronary balloon angioplasty. Plasma CoQ10 concentrations were measured before primary angioplasty (baseline) and 3 days, 7 days, and 1 month after STEMI using high-performance liquid chromatography. Echocardiography was performed at baseline and at 6-month follow-up. The control group comprised 54 healthy age- and sex-matched volunteers. Serial circulating CoQ10 concentrations significantly decreased with time in the STEMI group. The LV ejection fraction at 6-month follow-up positively correlated with the 1-month plasma CoQ10 tertile. Higher plasma CoQ10 concentrations at 1 month were associated with favorable LV remodeling and systolic function 6 months after STEMI. Multiple linear regression analysis showed that changes in CoQ10 concentrations at 1-month follow-up were predictive of LV systolic function 6 months after STEMI. Changes in CoQ10 concentrations correlated negatively with baseline oxidized low-density lipoprotein and fibrinogen concentrations and correlated positively with leukocyte mitochondrial copy number at baseline. Patients with STEMI who had higher plasma CoQ10 concentrations 1 month after primary angioplasty had better LV performance at 6-month follow-up. In addition, higher plasma CoQ10 concentration was associated with lower grade inflammatory and oxidative stress status. Therefore, plasma CoQ10 concentration may serve as a novel prognostic biomarker of LV systolic function after revascularization therapy for acute myocardial infarction. PMID:27495100

  6. Cleft formation in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank E.; Brakke, Kenneth A.; Schur, Willi W.

    NASA’s development of a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, centers on a pumpkin shape super-pressure design. Under certain circumstances, it has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired state instead. Success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and developing of means for the quantitative assessment of design measures that prevent the occurrence of undesired equilibrium. In this paper, we will use the concept of stability to classify cyclically symmetric equilibrium states at full inflation and pressurization. Our mathematical model for a strained equilibrium balloon, when applied to a shape that mimics the Phase IV-A balloon of Flight 517, predicts instability at float. Launched in Spring 2003, this pumpkin balloon failed to deploy properly. Observations on pumpkin shape type super-pressure balloons that date back to the 1980s suggest that within a narrowly defined design class of pumpkin shape super-pressure balloons where individual designs are fully described by the number of gores ng and by a single measure of the bulging gore shape, the designs tend to become more vulnerable with the growing number of gores and with the diminishing size of the bulge radius rB Weight efficiency considerations favor a small bulge radius, while robust deployment into the desired cyclically symmetrical configuration becomes more likely with an increased bulge radius. In an effort to quantify this dependency, we will explore the stability of a family of balloon shapes parametrized by (ng, rB) which includes a design that is very similar, but not identical, to the balloon of Flight 517. In addition, we carry out a number of simulations that demonstrate other aspects related to multiple equilibria of pumpkin balloons.

  7. Breakthrough in Mars balloon technology

    Science.gov (United States)

    Kerzhanovich, V. V.; Cutts, J. A.; Cooper, H. W.; Hall, J. L.; McDonald, B. A.; Pauken, M. T.; White, C. V.; Yavrouian, A. H.; Castano, A.; Cathey, H. M.; Fairbrother, D. A.; Smith, I. S.; Shreves, C. M.; Lachenmeier, T.; Rainwater, E.; Smith, M.

    2004-01-01

    Two prototypes of Mars superpressure balloons were flight tested for aerial deployment and inflation in the Earth's stratosphere in June, 2002. One was an 11.3 m diameter by 6.8 m high pumpkin balloon constructed from polyethylene film and Zylon (PBO) tendons, the second was a 10 m diameter spherical balloon constructed from 12 μm thick Mylar film. Aerial deployment and inflation occurred under parachute descent at 34 km altitude, mimicing the dynamic pressure environment expected during an actual Mars balloon mission. Two on-board video cameras were used on each flight to provide real-time upward and downward views of the flight train. Atmospheric pressure and temperature were also recorded. Both prototypes successfully deployed from their storage container during parachute descent at approximately 40 m/s. The pumpkin balloon also successfully inflated with a 440 g charge of helium gas injected over a 1.5-min period. Since the helium inflation system was deliberately retained after inflation in this test, the pumpkin balloon continued to fall to the ocean where it was recovered for post-flight analysis. The less robust spherical balloon achieved only a partial (~70%) inflation before a structural failure occurred in the balloon film resulting in the loss of the vehicle. This structural failure was diagnosed to result from the vigorous oscillatory motion of the partially inflated balloon, possibly compounded by contact between the balloon film and an instrumentation box above it on the flight train. These two flights together represent significant progress in the development of Mars superpressure balloon technology and pave the way for future flight tests that will include post-deployment flight of the prototype balloons at a stable altitude.

  8. Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery

    International Nuclear Information System (INIS)

    Background: To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Methods: Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. Results: The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Conclusions: Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found

  9. Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Weber, W. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany); Mayer, T.E. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Henkes, H. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany); Kis, B. [Department of Neurology, Alfried Krupp Hospital, Essen (Germany) and Department of Psychiatry and Psychotherapy, University of Duisburg-Essen, Virchow Street 174, D-45147 Essen (Germany)]. E-mail: bernhard.kis@uni-duisburg-essen.de; Hamann, G.F. [Department of Neurology, Klinikum Grosshadern, University of Munich (Germany); Holtmannspoetter, M. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Brueckmann, H. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Kuehne, D. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany)

    2005-11-01

    Background: To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Methods: Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. Results: The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Conclusions: Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found.

  10. Primary Infrainguinal Subintimal Angioplasty in Diabetic Patients

    International Nuclear Information System (INIS)

    The aim of this study was to prospectively evaluate technical and clinical results of infrainguinal subintimal angioplasty in a series of diabetic patients with limb-threatening ischemia. From July 2003 to December 2007, 60 consecutive diabetic patients (M/F = 41/19; mean age, 69.4 ± 9.4 years) with Fontaine stage IV critical limb ischemia, not suitable for surgical recanalization, underwent primary infrainguinal subintimal angioplasty. The technical success, perioperative morbidity and mortality, and clinical success (defined by ulcer healing) were evaluated. Kaplan-Meier life-table analysis was obtained for cumulative clinical success, limb salvage, and survival rates. The procedure was technically successful in 55 of 60 (91.7%) patients; in 5 cases we were not able to achieve a reentry. Periprocedural mortality was 5% (3 patients); three patients (5%) required major amputation periprocedurally. Mean follow-up was 23 months (range, 0-48 months). On an intention-to-treat basis, the limb salvage rate was 93.3% (56/60 patients); ulcer healing was observed in 45 of 60 (75%) patients and it was significantly (p < 0.05) associated with serum creatinine and HbA1c levels, diabetes duration, and infrapopliteal recanalization. One- and three-year cumulative survival rates were 91.5% and 83.1%, respectively; serum creatinine levels, patient age, and clinical success were significant predictors of survival. In conclusion, infrainguinal primary subintimal angioplasty is a safe and effective treatment in diabetic patients with limb-threatening ischemia not suitable for surgical recanalization. This procedure is aimed to create a 'temporary bypass' that facilitates ulcer healing.

  11. Carotid angioplasty and stenting in the elderly

    International Nuclear Information System (INIS)

    To investigate the technical success rate as well as the procedural and mid-term complication rates of carotid angioplasty and stenting in elderly patients, a group excluded from large randomized endarterectomy trials given their perceived high surgical risk. Of 200 consecutive carotid angioplasty and/or stenting procedures performed between March 1996 and March 2005, 21 procedures were performed without cerebral protection devices in 20 patients over the age of 79 years (mean age: 83 years, 12 men, eight women). These patients' medical records were retrospectively reviewed for vascular imaging reports and available clinical follow-up. Procedural and mid-term complication rates were calculated and compared to a previously published cohort of 133 consecutive patients ≤79 years of age who also underwent endovascular treatment at our institution. Carotid stenosis was reduced from a mean of 82% to no significant stenosis in all procedures. The procedural stroke rate was zero of 21 procedures. The procedural transient ischemic attack rate (TIA) was one of 21 procedures (4.8%). Mean follow-up was 24.6 months (range: 1.0-79.5 months) with at least a 30-day follow-up for 20 of the 21 procedures (95.2%). There were no new strokes. There was one recurrent ipsilateral TIA at 1.9 months. In five cases with follow-up carotid ultrasonography, no hemodynamically significant restenosis had occurred. There were three myocardial infarctions (MI) occurring at 0.5, 2.1, and 15.2 months, of which the last MI was fatal. The composite 30-day stroke and death rate was zero of 21 procedures (95% confidence interval: 0-14%). No significant difference was found in the 30-day rate of stroke, TIA, MI, or death between the elderly and younger patients. Carotid angioplasty and stenting in elderly patients can be performed successfully with acceptable procedural and mid-term complication rates comparable to younger patients. (orig.)

  12. Carotid angioplasty and stenting in the elderly

    Energy Technology Data Exchange (ETDEWEB)

    Kadkhodayan, Yasha [Washington University School of Medicine, Interventional Neuroradiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Cross, DeWitte T.; Moran, Christopher J. [Washington University School of Medicine, Interventional Neuroradiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurological Surgery, St. Louis, MO (United States); Derdeyn, Colin P. [Washington University School of Medicine, Interventional Neuroradiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurological Surgery, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurology, St. Louis, MO (United States)

    2007-11-15

    To investigate the technical success rate as well as the procedural and mid-term complication rates of carotid angioplasty and stenting in elderly patients, a group excluded from large randomized endarterectomy trials given their perceived high surgical risk. Of 200 consecutive carotid angioplasty and/or stenting procedures performed between March 1996 and March 2005, 21 procedures were performed without cerebral protection devices in 20 patients over the age of 79 years (mean age: 83 years, 12 men, eight women). These patients' medical records were retrospectively reviewed for vascular imaging reports and available clinical follow-up. Procedural and mid-term complication rates were calculated and compared to a previously published cohort of 133 consecutive patients {<=}79 years of age who also underwent endovascular treatment at our institution. Carotid stenosis was reduced from a mean of 82% to no significant stenosis in all procedures. The procedural stroke rate was zero of 21 procedures. The procedural transient ischemic attack rate (TIA) was one of 21 procedures (4.8%). Mean follow-up was 24.6 months (range: 1.0-79.5 months) with at least a 30-day follow-up for 20 of the 21 procedures (95.2%). There were no new strokes. There was one recurrent ipsilateral TIA at 1.9 months. In five cases with follow-up carotid ultrasonography, no hemodynamically significant restenosis had occurred. There were three myocardial infarctions (MI) occurring at 0.5, 2.1, and 15.2 months, of which the last MI was fatal. The composite 30-day stroke and death rate was zero of 21 procedures (95% confidence interval: 0-14%). No significant difference was found in the 30-day rate of stroke, TIA, MI, or death between the elderly and younger patients. Carotid angioplasty and stenting in elderly patients can be performed successfully with acceptable procedural and mid-term complication rates comparable to younger patients. (orig.)

  13. Titan Balloon Convection Model Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This innovative research effort is directed at determining, quantitatively, the convective heat transfer coefficients applicable to a Montgolfiere balloon operating...

  14. Occult, massive hematomas following antegrade femoral angioplasty

    International Nuclear Information System (INIS)

    Small groin hematomas are not uncommon after percuatenous antegrade femoral angioplasty (PAFA) and are usually apparent clinically. The authors describe three patients of 235 who underwent PAFA, in whom occult, massive hemorrhage was detected after the procedure. All patients underwent fluoroscopically guided antegrade punctures, with adequate hemostasis achieved after the procedure. CT revealed extraperitoneal hematomas in two patients. One patient required surgical intervention with ligation of the inferior epigastric artery. The authors postulate that these hematomas arose due to inadvertent injury to a branch of the common femoral artery during the puncture. The radiologist should be aware of the chance occurrence of this occult, potentially life-threatening complication

  15. Application of new balloon catheters in the treatment of congenital heart defects

    Science.gov (United States)

    Fiszer, Roland; Szkutnik, Małgorzata; Smerdziński, Sebastian; Chodór, Beata; Białkowski, Jacek

    2016-01-01

    Introduction Balloon angioplasty (BAP) and aortic or pulmonary balloon valvuloplasty (BAV, BPV) are well-established treatment options in congenital heart defects. Recently, significant technological progress has been made and new catheters have been implemented in clinical practice. Aim To analyze the results of BAP, BAV and BPV with the new balloon catheter Valver and its second generation Valver II, which the company Balton (Poland) launched and developed. These catheters have not been clinically evaluated yet. Material and methods We performed 64 interventions with Valver I and Valver II. With Valver I the following procedures were performed: 17 BPV (including 9 in tetralogy of Fallot – TOF), 10 BAV and 27 BAP in coarctations of the aorta (CoA) – including 9 native and 18 after surgery. With Valver II ten interventions were done – 3 BPV, 2 pulmonary supravalvular BAP (after switch operations), 2 BAP of recoarctations and 3 other BAP. Age of the patients ranged from a few days to 40 years. Results All procedures were completed successfully, without rupture of any balloon catheters. The pressure gradient drop was statistically significant in all groups: BPV in isolated pulmonary valvular stenosis 28.1 mm Hg (mean), BPV in TOF 18.7 mm Hg, BAV 32.8 mm Hg, BAP in native CoA 15.4 mm Hg and in recoarctations 18.6 mm Hg. In 3 cases during rapid deflation of Valver I, wrinkles of the balloons made it impossible to insert the whole balloon into the vascular sheath (all were removed surgically from the groin). No such complication occured with Valver II. Conclusions Valver balloon catheters are an effective treatment modality in different valvular and vascular stenoses. PMID:27625686

  16. Development of novel short-term heating angioplasty: thermal denaturation dynamics of collagen in artery wall

    Science.gov (United States)

    Shimazaki, N.; Tokunaga, H.; Katou, Y.; Hayashi, T.; Arai, T.

    2009-02-01

    We have studied to develop the new thermal angioplasty methodology, photo-thermo dynamic balloon angioplasty (PTDBA), which provides artery dilatation with short-term (<15s) and uniform heating through the balloon by the combination of the efficient laser driven heat generation and fluid perfusion. Thermal denaturation degree of the collagen in artery media may be the important factor to attain sufficient artery dilatation for the PTDBA. In order to predict the optimum heating condition i.e. the balloon temperature and heating duration, we investigated the thermal denaturation dynamics of artery collagen in ex vivo. The extracted fresh porcine carotid artery was used. The temperature-dependent light scattering property and mechanical property of the artery specimen were simultaneously measured during artery temperature rising by specially made setup to assess the denaturation of arterial collagen. The change rate of the backscattered light intensity from the artery specimen; I(T)/I0 with 633nm was measured to evaluate the artery scattering property change with the thermal denaturation. The artery specimen was heated from 25°C to 80°C with constant temperature rising rate of 3°C/min. The measured I(T)/I0 was suddenly increased over 48°C. This boundary temperature might be the initiation temperature of the arterial collagen denaturation. We defined the variation of the I(T)/I0 as the collagen denaturation ratio, and calculated the reactive enthalpy by the chemical equilibrium theory. Since the calculated enthalpy was similar to the enthalpy in literature report, the variety of I(T)/I0 during the temperature rising might be attributed to the collagen conformational change due to the denaturation. In terms of the artery internal force measurement, the artery force was decreased with increasing of the artery temperature up to 65°C (i.e. softening), and increased over 65°C (i.e. shrinkage). We confirmed that the changes of the backscattered light (at 633nm in

  17. Magnetic Particle / Magnetic Resonance Imaging: In-Vitro MPI-Guided Real Time Catheter Tracking and 4D Angioplasty Using a Road Map and Blood Pool Tracer Approach

    Science.gov (United States)

    Jung, Caroline; Kaul, Michael Gerhard; Werner, Franziska; Them, Kolja; Reimer, Rudolph; Nielsen, Peter; vom Scheidt, Annika; Adam, Gerhard; Knopp, Tobias; Ittrich, Harald

    2016-01-01

    Purpose In-vitro evaluation of the feasibility of 4D real time tracking of endovascular devices and stenosis treatment with a magnetic particle imaging (MPI) / magnetic resonance imaging (MRI) road map approach and an MPI-guided approach using a blood pool tracer. Materials and Methods A guide wire and angioplasty-catheter were labeled with a thin layer of magnetic lacquer. For real time MPI a custom made software framework was developed. A stenotic vessel phantom filled with saline or superparamagnetic iron oxide nanoparticles (MM4) was equipped with bimodal fiducial markers for co-registration in preclinical 7T MRI and MPI. In-vitro angioplasty was performed inflating the balloon with saline or MM4. MPI data were acquired using a field of view of 37.3×37.3×18.6 mm3 and a frame rate of 46 volumes/sec. Analysis of the magnetic lacquer-marks on the devices were performed with electron microscopy, atomic absorption spectrometry and micro-computed tomography. Results Magnetic marks allowed for MPI/MRI guidance of interventional devices. Bimodal fiducial markers enable MPI/MRI image fusion for MRI based roadmapping. MRI roadmapping and the blood pool tracer approach facilitate MPI real time monitoring of in-vitro angioplasty. Successful angioplasty was verified with MPI and MRI. Magnetic marks consist of micrometer sized ferromagnetic plates mainly composed of iron and iron oxide. Conclusions 4D real time MP imaging, tracking and guiding of endovascular instruments and in-vitro angioplasty is feasible. In addition to an approach that requires a blood pool tracer, MRI based roadmapping might emerge as a promising tool for radiation free 4D MPI-guided interventions. PMID:27249022

  18. Magnetic Particle / Magnetic Resonance Imaging: In-Vitro MPI-Guided Real Time Catheter Tracking and 4D Angioplasty Using a Road Map and Blood Pool Tracer Approach.

    Directory of Open Access Journals (Sweden)

    Johannes Salamon

    Full Text Available In-vitro evaluation of the feasibility of 4D real time tracking of endovascular devices and stenosis treatment with a magnetic particle imaging (MPI / magnetic resonance imaging (MRI road map approach and an MPI-guided approach using a blood pool tracer.A guide wire and angioplasty-catheter were labeled with a thin layer of magnetic lacquer. For real time MPI a custom made software framework was developed. A stenotic vessel phantom filled with saline or superparamagnetic iron oxide nanoparticles (MM4 was equipped with bimodal fiducial markers for co-registration in preclinical 7T MRI and MPI. In-vitro angioplasty was performed inflating the balloon with saline or MM4. MPI data were acquired using a field of view of 37.3×37.3×18.6 mm3 and a frame rate of 46 volumes/sec. Analysis of the magnetic lacquer-marks on the devices were performed with electron microscopy, atomic absorption spectrometry and micro-computed tomography.Magnetic marks allowed for MPI/MRI guidance of interventional devices. Bimodal fiducial markers enable MPI/MRI image fusion for MRI based roadmapping. MRI roadmapping and the blood pool tracer approach facilitate MPI real time monitoring of in-vitro angioplasty. Successful angioplasty was verified with MPI and MRI. Magnetic marks consist of micrometer sized ferromagnetic plates mainly composed of iron and iron oxide.4D real time MP imaging, tracking and guiding of endovascular instruments and in-vitro angioplasty is feasible. In addition to an approach that requires a blood pool tracer, MRI based roadmapping might emerge as a promising tool for radiation free 4D MPI-guided interventions.

  19. Buddy balloon for TAVI.

    Science.gov (United States)

    Balkin, Jonathan; Silberman, Shuli; Almagor, Yaron

    2013-11-15

    Percutaneous transfemoral aortic valve replacement is a new rapidly evolving technique that has made significant progress in recent years. The technology is however limitted and in some cases has resulted in failure to deliver the prosthetic valve. We describe a new technique using a buddy balloon, from the contralateral femoral artery, to assist in crossing the native aortic valve in those cases where extreme calcification and or tortuosity have caused the delivery system to hang up on the aortic wall. The technique is easily applied and facilitates the success of the procedure in cases which may otherwise have to be converted to open surgical aortic valve replacement.

  20. Treatment of pacemaker-induced superior vena cava syndrome by balloon angioplasty and stenting.

    LENUS (Irish Health Repository)

    Klop, B

    2011-01-01

    Superior vena cava (SVC) syndrome is a rare but serious complication after pacemaker implantation. This report describes three cases of SVC syndrome treated with venoplasty and venous stenting, with an average follow-up of 30.7 (±3.1) months. These cases illustrate that the definitive diagnosis, and the extent and location of venous obstruction, can only be determined by venography.

  1. A Methane Balloon Inflation Chamber

    Science.gov (United States)

    Czerwinski, Curtis J.; Cordes, Tanya J.; Franek, Joe

    2005-01-01

    The various equipments, procedure and hazards in constructing the device for inflating a methane balloon using a standard methane outlet in a laboratory are described. This device is fast, safe, inexpensive, and easy to use as compared to a hydrogen gas cylinder for inflating balloons.

  2. Percutaneous transluminal angioplasty of infrarenal arteries in intermittent claudication

    DEFF Research Database (Denmark)

    Henriksen, L O; Jørgensen, B; Holstein, P E;

    1988-01-01

    Percutaneous transluminal angioplasty was performed on 55 iliac and 31 femoropopliteal arteries in 71 patients with intermittent claudication (23 women, 48 men). The two-year patency rate was 80% after iliac and 41% after femoropopliteal angioplasty. In 17 femoropopliteal cases with lesions greater...... than or equal to 5 cm the 2-year patency rate was only 32%, but the corresponding figure for shorter lesions was 53%. Complicating haematoma appeared in 10% of the cases and the arterial state deteriorated in one patient. There was no distal embolization. Percutaneous transluminal angioplasty...

  3. Nationwide Eclipse Ballooning Project

    Science.gov (United States)

    Colman Des Jardins, Angela; Berk Knighton, W.; Larimer, Randal; Mayer-Gawlik, Shane; Fowler, Jennifer; Harmon, Christina; Koehler, Christopher; Guzik, Gregory; Flaten, James; Nolby, Caitlin; Granger, Douglas; Stewart, Michael

    2016-05-01

    The purpose of the Nationwide Eclipse Ballooning Project is to make the most of the 2017 rare eclipse event in four main areas: public engagement, workforce development, partnership development, and science. The Project is focused on two efforts, both student-led: online live video of the eclipse from the edge of space and the study of the atmospheric response to the eclipse. These efforts, however, involving more than 60 teams across the US, are challenging in many ways. Therefore, the Project is leveraging the NASA Space Grant and NOAA atmospheric science communities to make it a success. The first and primary topic of this poster is the NASA Space Grant supported online live video effort. College and high school students on 48 teams from 31 states will conduct high altitude balloon flights from 15-20 locations across the 8/21/2017 total eclipse path, sending live video and images from near space to a national website. Video and images of a total solar eclipse from near space are fascinating and rare. It’s never been done live and certainly not in a network of coverage across a continent. In addition to the live video to the web, these teams are engaged in several other science experiments as secondary payloads. We also briefly highlight the eclipse atmospheric science effort, where about a dozen teams will launch over one hundred radiosondes from across the 2017 path, recording an unprecedented atmospheric data sample. Collected data will include temperature, density, wind, humidity, and ozone measurements.

  4. Clopidogrel Responsiveness in Patients Undergoing Peripheral Angioplasty

    International Nuclear Information System (INIS)

    Purpose: To investigate the incidence and clinical significance of platelet responsiveness in patients receiving clopidogrel after peripheral angioplasty procedures. Materials and Methods: This prospective study included patients receiving antiplatelet therapy with clopidogrel 75 mg after infrainguinal angioplasty or stenting and who presented to our department during routine follow-up. Clopidogrel responsiveness was tested using the VerifyNow P2Y12 Assay. Patients with residual platelet reactivity units (PRU) ≥ 235 were considered as nonresponders (NR group NR), whereas patients with PRU < 235 were considered as normal (responders [group R]). Primary end points were incidence of resistance to clopidogrel and target limb reintervention (TLR)-free survival, whereas secondary end points included limb salvage rates and the identification of any independent predictors influencing clinical outcomes. Results: In total, 113 consecutive patients (mean age 69 ± 8 years) with 139 limbs were enrolled. After clopidogrel responsiveness analysis, 61 patients (53.9 %) with 73 limbs (52.5 %) were assigned to group R and 52 patients (46.1 %) with 66 limbs (47.5 %) to group NR. Mean follow-up interval was 27.7 ± 22.9 months (range 3–95). Diabetes mellitus, critical limb ischemia, and renal disease were associated with clopidogrel resistance (Fisher’s exact test; p < 0.05). According to Kaplan–Meier analysis, TLR-free survival was significantly superior in group R compared with group NR (20.7 vs. 1.9 %, respectively, at 7-year follow-up; p = 0.001), whereas resistance to clopidogrel was identified as the only independent predictor of decreased TLR-free survival (hazard rate 0.536, 95 % confidence interval 0.31–0.90; p = 0.01). Cumulative TLR rate was significantly increased in group NR compared with group R (71.2 % [52 of 73] vs. 31.8 % [21 of 66], respectively; p < 0.001). Limb salvage was similar in both groups. Conclusion: Clopidogrel resistance was related with

  5. Clopidogrel Responsiveness in Patients Undergoing Peripheral Angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Pastromas, Georgios, E-mail: geopastromas@gmail.com; Spiliopoulos, Stavros, E-mail: stavspiliop@upatras.gr; Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Diamantopoulos, Athanasios, E-mail: adiamantopoulos@gmail.com; Kitrou, Panagiotis, E-mail: panoskitrou@gmail.com; Karnabatidis, Dimitrios, E-mail: karnaby@med.upatras.gr; Siablis, Dimitrios, E-mail: siablis@med.upatras.gr [Patras University Hospital, Department of Interventional Radiology (Greece)

    2013-12-15

    Purpose: To investigate the incidence and clinical significance of platelet responsiveness in patients receiving clopidogrel after peripheral angioplasty procedures. Materials and Methods: This prospective study included patients receiving antiplatelet therapy with clopidogrel 75 mg after infrainguinal angioplasty or stenting and who presented to our department during routine follow-up. Clopidogrel responsiveness was tested using the VerifyNow P2Y12 Assay. Patients with residual platelet reactivity units (PRU) {>=} 235 were considered as nonresponders (NR group NR), whereas patients with PRU < 235 were considered as normal (responders [group R]). Primary end points were incidence of resistance to clopidogrel and target limb reintervention (TLR)-free survival, whereas secondary end points included limb salvage rates and the identification of any independent predictors influencing clinical outcomes. Results: In total, 113 consecutive patients (mean age 69 {+-} 8 years) with 139 limbs were enrolled. After clopidogrel responsiveness analysis, 61 patients (53.9 %) with 73 limbs (52.5 %) were assigned to group R and 52 patients (46.1 %) with 66 limbs (47.5 %) to group NR. Mean follow-up interval was 27.7 {+-} 22.9 months (range 3-95). Diabetes mellitus, critical limb ischemia, and renal disease were associated with clopidogrel resistance (Fisher's exact test; p < 0.05). According to Kaplan-Meier analysis, TLR-free survival was significantly superior in group R compared with group NR (20.7 vs. 1.9 %, respectively, at 7-year follow-up; p = 0.001), whereas resistance to clopidogrel was identified as the only independent predictor of decreased TLR-free survival (hazard rate 0.536, 95 % confidence interval 0.31-0.90; p = 0.01). Cumulative TLR rate was significantly increased in group NR compared with group R (71.2 % [52 of 73] vs. 31.8 % [21 of 66], respectively; p < 0.001). Limb salvage was similar in both groups. Conclusion: Clopidogrel resistance was related with

  6. Subintimal angioplasty for femoro-popliteal occlusive disease.

    Science.gov (United States)

    Markose, George; Miller, Fiona N A C; Bolia, Amman

    2010-11-01

    There has been a longstanding debate about the roles of surgical bypass graft, percutaneous transluminal angioplasty, subintimal angioplasty, and conservative management for femoro-popliteal occlusive disease. Subintimal angioplasty was first described in 1987 as a method of performing an endovascular arterial bypass. The subintimal space at the start of the occlusion is entered with a catheter and a wire loop is used to cross the occlusion and reenter the vessel lumen distally. In patients with critical limb ischemia, there is high quality evidence demonstrating that the limb salvage rate and amputation-free survival rates for surgery and endovascular treatment are similar, but surgery is more expensive than angioplasty in the short term. In patients with intermittent claudication, surgical bypass using an autologous saphenous vein graft is currently believed to be the gold standard, but this is increasingly questioned in the light of recent advances in endovascular techniques. Surgical bypass with vein graft offers a 2-year patency of 81%, compared with 67% for a polytetrafluoroethylene (PTFE) graft and at best 67% for subintimal angioplasty. The better patency offered by surgery must be balanced against a higher morbidity and mortality. To conclude, subintimal angioplasty is an extremely valuable technique in the management of critical limb ischemia. Based on the evidence to date, this technique is likely to have an increasing role in the management of intermittent claudication over the coming years, particularly if the risk of general anaesthesia is high or there is no suitable vein.

  7. Percutaneous transluminal angioplasty in a patient with chronic cerebrospinal venous insufficiency and persistent left superior vena cava.

    Science.gov (United States)

    Lupattelli, T; Benassi, F; Righi, E; Bavera, P; Bellagamba, G

    2014-04-01

    Chronic cerebrospinal venous insufficiency (CCSVI) is a syndrome characterized by stenoses of the internal jugular veins (IJVs) and/or azygos veins and formation of collateral venous channels. A case of a 57-year-old patient with CCSVI in whom the venous outflow from the left IJV to the right atrium occurred through a venous anomaly, the persistent left superior vena cava (PLSVC), is reported. PLSVC is caused by persistence of the left anterior cardinal vein that drains blood from the limb effluent from the left and the left side of head and neck into coronary sinus (Type a), or in the left atrium (Type b). PLSVC can be associated either with innominate vein hypoplasia or other congenital heart abnormalities. Because of evidence of left innominate vein hypoplasia, angioplasty was not performed using the ordinary route but passing with the balloon directly through the PLSVC up to the left IJV. Finally, angioplasty was carried out in a standard manner in the right IJV as well as in the azygous vein. Confirmation angiogram revealed complete reopening of all treated vessels with no evidence of peri- and postoperative complications. The patient was discharged home the following day in good general conditions. PLSVC is a rare congenital vein anomaly but in case of concomitant innominate vein hypoplasia may prove to be a valuable alternative to treat patients with IJV diseases.

  8. Angioplasty of forearm arteries as a finger salvage procedure for patient with end-stage renal failure.

    Science.gov (United States)

    Law, Yuk; Chan, Yiu Che; Cheng, Stephen Wing-Keung

    2016-01-01

    Due to the relatively low metabolic demand and extensive collaterals of the upper limb, peripheral arterial disease seldom leads to tissue loss, except in patients with end-stage renal failure (ESRF), rheumatologic diseases, Raynaud's disease, frostbites, or distal emboli. We report a case of a 51-year-old lady with ESRF who presented to our tertiary referral vascular center with infected gangrene of her right ring finger. Duplex ultrasound showed that her forearm arteries were severely diseased. Digital subtraction angiogram showed severe multilevel stenoses/occlusions in her forearm radial and ulnar arteries. These lesions were successfully angioplastized with 2 mm × 25 mm angioplasty balloon. Completion angiogram showed good radiological results with some post-dilatation spasm which improved with intra-arterial glyceryl trinitrate. The sepsis improved after revascularization, and the distal phalanx was allowed to self-demarcate with dressings and autoamputate with good clinical results. Our case illustrated that even in delayed setting, patients could still benefit from specialist vascular care with a combination of expert care and angioplasty of forearm arteries, with successful salvage of her finger. PMID:27143949

  9. Percutaneous Transluminal Angioplasty of Hepatic Artery Stenosis in Patients After Orthotopic Liver Transplantation: Mid-term Results

    International Nuclear Information System (INIS)

    Purpose: This study was designed to present our experience with percutaneous treatment of hepatic artery stenosis in orthotopic liver transplant patients and to evaluate the efficacy, technical outcomes, and mid-term clinical results of the procedure. Methods: Twenty-two percutaneous transluminal angioplasties (PTAs) were performed in 19 liver transplant recipients at our institution between 1998 and 2010. Stents were placed into the hepatic/celiac artery in 16 PTAs, but balloon dilatation alone was performed in 6 because of the anatomical condition of the vessel. PTA/stenting was indicated in 17 patients because of elevated liver enzymes; 2 patients were asymptomatic. The objective of treating stenosis was prevention of long-term complications, including thrombosis. Results: Technical success was achieved in all patients. There was only one complication: dissection of the treated artery without any subsequent adverse effects. In all patients, elevated liver enzyme levels improved after treatment. No restenosis was observed in any patient during a mean follow-up of 2.6 years (1 month to 5.5 years). Conclusions: Percutaneous angioplasty/stent placement is a safe method for the treatment of hepatic artery stenosis after orthotopic liver transplantation, with a high technical success rate and promising mid-term results.

  10. US Air Force Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Worksheets containing pilot balloon data computed from releases at Air Force stations in the western United States. Elevation and azimuth angles are used to compute...

  11. Superpressure Tow Balloon for Extending Durations and Modifying Trajectories of High Altitude Balloon Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation involves the concept of using a Superpressure Tow Balloon (STB) with existing NASA high altitude balloon designs to form a tandem balloon...

  12. Simple balloon dilation for drug-eluting in-stent restenosis: An optical coherent tomography analysis

    Energy Technology Data Exchange (ETDEWEB)

    Arikawa, Ryo [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Yamaguchi, Hiroshi, E-mail: hyamaguchi@tsm.bbiq.jp [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Takaoka, Junichiro; Miyamura, Akihiro; Atsuchi, Nobuhiko; Ninomiya, Toshiko; Atsuchi, Yoshihiko [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Ohishi, Mitsuru [Department of Cardiovascular Medicine and Hypertension, Graduate School of Medical and Dental Science, Kagoshima University, Kagoshima (Japan); Terashima, Mitsuyasu [Department of Cardiology, Toyohashi Heart Center, Toyohashi (Japan); Kaneda, Hideaki [Okinaka Memorial Institute for Medical Research, Tokyo (Japan)

    2015-01-15

    Background: Although drug-eluting stent (DES) has significantly reduced restenosis, the treatment of DES-in-stent restenosis (ISR) remains a challenge with high restenosis rate. Methods: We examined whether morphologic appearance of restenosis tissue by optical coherent tomography (OCT) had an impact on outcomes after balloon angioplasty for DES-ISR. The morphologic appearance of restenosis tissue was qualitatively assessed for tissue structures such as homogeneous, layered, and heterogeneous patterns. Results: Using OCT, 50 patients with DES-ISR were divided into 2 groups: 25 lesions with homogeneous or layered patterns (homo/layered group) and 25 lesions with heterogeneous patterns (hetero group). Acute gain was larger in the hetero group (1.33 ± 0.41 mm vs. 1.06 ± 0.32 mm in the homo/layered group, P = 0.03). On intravascular ultrasound analysis, post-procedural percent neointimal area was smaller in the hetero group (27.4 ± 9.2% vs. 34.0 ± 11.2% in the homo/layered group, P = 0.05). Angiographic follow-up was performed in 37 lesions (74%). Follow-up minimal lumen diameter was larger in the hetero group (1.75 ± 0.89 mm vs. 1.01 ± 0.81 mm in the homo/layered group, P = 0.04). Target lesion revascularization rates tended to be lower in the hetero group (20% vs. 43% in the homo/layered group, P = 0.12). Conclusions: Balloon angioplasty was more effective for DES-ISR with heterogeneous tissue appearance than DES-ISR with homogeneous/layered tissue appearance. OCT assessment of DES-ISR morphology may be a useful adjunct in determining clinical strategies. Simple balloon dilatation is a possible treatment strategy for DES-ISR lesions with a heterogeneous appearance on OCT images.

  13. Serum iron concentration, but not hemoglobin, correlates with TIMI risk score and 6-month left ventricular performance after primary angioplasty for acute myocardial infarction.

    Directory of Open Access Journals (Sweden)

    Ching-Hui Huang

    Full Text Available Anemia is associated with high mortality and poor prognosis after acute coronary syndrome (ACS. Increased red cell distribution width (RDW is a strong independent predictor for adverse outcomes in ACS. The common underlying mechanism for anemia and increased RDW value is iron deficiency. It is not clear whether serum iron deficiency without anemia affects left ventricular (LV performance after primary angioplasty for acute myocardial infarction (AMI. We investigated the prognostic value of serum iron concentration on LV ejection fraction (EF at 6 months and its relationship to thrombolysis in myocardial infarction (TIMI risk score in post MI patients.We recruited 55 patients who were scheduled to undergo primary coronary balloon angioplasty after AMI and 54 age- and sex-matched volunteers. Serum iron concentration and interleukin-6 levels were measured before primary angioplasty. LVEF was measured by echocardiography at baseline and after 6 months. TIMI risk score was calculated for risk stratification.Serum iron concentration was significantly lower in those in whom LVEF had not improved ≥ 10% from baseline (52.7 ± 24.1 versus 80.8 ± 50.8 µg/dl, P = 0.016 regardless of hemoglobin level, and was significantly lower in the AMI group than in the control group (62.5 ± 37.7 versus 103.0 ± 38.1 µg/dl, P<0.001. Trend analysis revealed that serum iron concentration decreased as TIMI risk score increased (P = 0.002. In addition, lower serum iron concentrations were associated with higher levels of inflammatory markers. Multiple linear regression showed that baseline serum iron concentration can predict LV systolic function 6 months after primary angioplasty for AMI even after adjusting for traditional prognostic factors.Hypoferremia is not only a marker of inflammation but also a potential prognostic factor for LV systolic function after revascularization therapy for AMI, and may be a novel biomarker for therapeutic intervention.

  14. Astro research fellowship: low dose radiation to prevent restenosis after angioplasty

    International Nuclear Information System (INIS)

    Purpose: To determine the optimal time to deliver a single dose of external radiation therapy (12 Gy) postoperatively following balloon angioplasty (on same day, day 2 or day 4) to prevent restenosis in a non-stented swine model. To model an endovascular radioactive source for prevention of restenosis in the same animal model. Materials and Methods: Both external iliac arteries in eleven red duroc swine were injured using balloon overdilation (3 inflations, 60 secs. each, 16 psi), and the first five were additionally injured using denudation. One artery in each animal was then irradiated using anteroposterior and posterioranterior fields using Co-60 with 12 Gy prescribed to the midplane, with the other artery serving as a control. Irradiation was delivered on the same day, day 2 or day 4. Animals were sacrificed 3 months following injury, and histomorphometric analysis was performed. Additionally, a prototype endovascular beta source was designed and manufactured for clinical testing, based on Monte Carlo estimations. Results: Neointima formation was noted in both radiated and control arteries. The mean neointimal thickness in the radiated and control arteries was 116 ± 39 μm and 131 ± 47 μm respectively. Time of radiation delivery did not have a significant effect in preventing restenosis. Physical measurements of the endovascular source are in progress using a water based phantom. Animal testing will commence on ten red duroc swine. Conclusion: External radiation at this low dose does not appear to prevent restenosis in an unstented animal model. We hope to begin animal experiments using an endovascular source to prevent restenosis

  15. Angioplasty and stent treatment of transplant renal artery stenosis.

    Science.gov (United States)

    Del Pozo, Maitane; Martí, Jordi; Guirado, Lluís; Facundo, Carme; Canal, Cristina; de la Torre, Pablo; Ballarín, José; Díaz, Joan M

    2012-07-17

    Transplant renal artery stenosis is a major complication that requires a therapeutic approach involving surgery or angioplasty. The aim of this study was to analyse the evolution of renal transplant patients with renal allograft artery stenosis treated by angioplasty and stent placement. Thirteen patients were diagnosed with transplant renal artery stenosis. Clinical suspicion was based on deterioration of renal function and/or poorly controlled hypertension with compatible Doppler ultrasound findings. The diagnosis was confirmed by arteriography, performing an angioplasty with stent placement during the same operation. A progressive improvement in renal function was observed during the first 3 months after the angioplasty, and renal function then remained stable over 2 years. In addition, blood pressure improved during the first 2 years, and as a consequence there was no need to increase the average number of anti-hypertensive drugs administered (2.5 drugs per patient). In conclusion, angioplasty with stent placement is a safe and effective procedure for the treatment of transplant renal artery stenosis.

  16. Mechanical and acoustic analysis in ultrasonic angioplasty

    Science.gov (United States)

    Detwiler, Paul W.; Watkins, James F.; Rose, Eric A.; Ratner, A.; Vu, Louis P.; Severinsky, J. Y.; Rosenschein, Uri

    1991-05-01

    The goal of this study was to investigate the relationship between ultrasonic tissue ablation and passive mechanical elasticity. Experience with ultrasonic angioplasty in experimental settings (in-vivo and in-vitro) together with clinical experience in peripheral vascular disease is reported. A model composed exclusively of a hydroxyproline ballistic gelatin matrix showed a negative correlation between material elasticity and the rate of ultrasonic ablation. This model provided a means of studying the effects of collagen content on ablation, exclusive of other biologic components. Ballistic gelatin ablation (mg/sec) was found to increase logarithmically with decreasing protein concentration over the range studied (20.00 to 1.25%). Ablation as a function of gelatin elasticity behaved in a similar manner. Temperature of the material ablated was also demonstrated to affect the rate of ablation. We conclude that the previously reported differences in ablation between thrombi and blood vessel are predictable based on the large difference in their mechanical elasticity, and that this difference provides a wide margin of safety.

  17. BLOCKING SUN WITH ORBITING BALLOONS

    Energy Technology Data Exchange (ETDEWEB)

    Chul Park [Department of Aerospace Engineering, Kor ea Advanced Institute of Science and Technology, Daejeon (Korea)

    2008-09-30

    Sun's radiation power reaching Earth's surface can be reduced by letting large balloons circle the Earth in orbits at approximately 1000 km altitude. These balloons, made of plastic films 1 mm in thickness, of a diameter of approximately 46 km, will weigh about 10,000 tons each. A balloon will consist of one hundred of 100 ton pieces. They are transported to the orbit piece by piece, and are assembled there into the spherical shape. They are kept inflated with the vapor pressure of potassium and the electrostatic forces. The inclination angles of these balloons with respect to the solar ecliptic plane can be varied from zero to 90 degrees, although efficiency is highest with the zero degree inclination. If zero degree inclination is chosen, twenty-three of these will reduce the average sun's radiation by 0.01%. In the 1000 km orbits, which are stable and are populated only by space debris, these balloons will serve also to remove the debris.

  18. Sensor System for Super-Pressure Balloon Performance Modeling Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Long-duration balloon flights are an exciting new area of scientific ballooning, enabled by the development of large super-pressure balloons. As these balloons...

  19. Balloon Exoplanet Nulling Interferometer (BENI)

    Science.gov (United States)

    Lyon, Richard G.; Clampin, Mark; Woodruff, Robert A.; Vasudevan, Gopal; Ford, Holland; Petro, Larry; Herman, Jay; Rinehart, Stephen; Carpenter, Kenneth; Marzouk, Joe

    2009-01-01

    We evaluate the feasibility of using a balloon-borne nulling interferometer to detect and characterize exosolar planets and debris disks. The existing instrument consists of a 3-telescope Fizeau imaging interferometer with 3 fast steering mirrors and 3 delay lines operating at 800 Hz for closed-loop control of wavefront errors and fine pointing. A compact visible nulling interferometer is under development which when coupled to the imaging interferometer would in-principle allow deep suppression of starlight. We have conducted atmospheric simulations of the environment above 100,000 feet and believe balloons are a feasible path forward towards detection and characterization of a limited set of exoplanets and their debris disks. Herein we will discuss the BENI instrument, the balloon environment and the feasibility of such as mission.

  20. Structure variations of pumpkin balloon

    Science.gov (United States)

    Yajima, N.; Izutsu, N.; Honda, H.

    2004-01-01

    A lobed pumpkin balloon by 3-D gore design concept is recognized as a basic form for a super-pressure balloon. This paper deals with extensions of this design concept for other large pressurized membrane structures, such as a stratospheric airship and a balloon of which volume is controllable. The structural modifications are performed by means of additional ropes, belts or a strut. When the original pumpkin shape is modified by these systems, the superior characteristics of the 3-D gore design, incorporating large bulges with a small local radius and unidirectional film tension, should be maintained. Improved design methods which are adequate for the above subjects will be discussed in detail. Application for ground structures are also mentioned.

  1. Limb-salvage angioplasty in poor surgical chronic liver disease and diabetic patients.

    Science.gov (United States)

    Hamdy, Hussam; El-Kolly, M; Ezzat, H; Abbas, M; Farouk, Y; Naser, M; Magdy, M; Elraouf, A

    2013-08-01

    Critical limb ischemia (CLI) in high surgical risk patients with chronic liver diseases has a grave prognosis with a one-year mortality rate of 20% and a one-year amputation rate of 25% after the initial diagnosis. According to Trans-Atlantic Inter-Society Consensus (TASC)-II Guidelines, revascularization (surgical & endovascular) is the treatment of choice for patients with critical limb ischemia (CLI). The primary goal of revascularization is to relieve ischemic rest pain, heal ulcers, prevent amputation, improve patient's quality of life (limb salvage) and secondary goal was the periprocedural complications. Endovascular techniques include balloon angioplasty, stents, stent-grafts, and plaque debulking procedures. Surgical options, identification of patients at risk of postoperative complications could have an impact on the indications for a procedure as well as permitting modifications of treatment to reduce the surgical risk This study evaluated the treatment out comas after limb salvage angioplasty for patients who otherwise would be candidates for primary amputation due to poor co-morbid conditions as chronic liver disease and diabetes. The clinical evaluation, laboratory investigations and abdominal ultrasonography were performed to all patients to evaluate their liver status. Patients were classified according to Child-pugh classification into child A, B & C. All patients were subjected to either detailed arterial duplex or C.T. angiography to assess their arterial lesions from January 2008- January 2010. 95 patients with critical limb ischemia (Rutherford categories 4, 5, 6) were treated by primary percutaneous transluminal angioplasty (PTA). No patient was excluded on the basis of the extent of arterial occlusive disease. The primary end points were immediate technical success, clinical improvement and limb salvages rates. Secondary end points were periprocedural complications and mortality. Most of the patients were male (54.7%) with mean age 62 (48

  2. Development of novel short-term heating angioplasty: diameter and elasticity change of vascular wall ex vivo

    Science.gov (United States)

    Shimazaki, Natsumi; Kaneko, Kenji; Nakatani, Eriko; Arai, Tsunenori

    2007-02-01

    In order to investigate the optimum operation parameters on novel short-term heating (angioplasty in which we demonstrated sufficient vascular dilatation with lower pressure by heat- induced denaturation of arterial collagen. And we have also demonstrated the suppression of intimal hyperplasia in animal experiments. We need to understand the PTDB dilatation mechanism to determine the optimum operation parameters. The prototype PTDB with diameter of 3mm was used in our experiments. The internal diameters of extracted fresh porcine carotid arteries at pre- and post- PTDB dilatation were measured. Balloon parameters were follows; pressure P=2atm, peak temperature in balloon T=60-80 °C, and heating duration t=4-30s. Morphological change in the media of dilated artery with PTDB were microscopically examined with Weigert staining. Elastic properties were carried out by stress-strain measurements with calculation of young's modulus. We found that PTDB dilatation provided the effect to prevent elastic recoil. We explained that the reason of this effect might be arrangement of micro- structure in the media, i.e., heat-denatured collagen fibers sustained the elastic recoil due to rubbery elastin fibers. The arterial elasticity was not significant different after PTDB dilatation. It was suggested that there could be no compliance mismatch after PTDB dilatation in physiological range. We found that a part of PTDB dilatation mechanism, in which the vascular wall structure played an important role. The optimum operation parameters for PTDB might be determined in consideration of collagen denaturation progress and arterial composition.

  3. The case for angioplasty in patients with symptomatic intracranial atherosclerosis.

    Science.gov (United States)

    McTaggart, Ryan A; Marks, Michael P

    2014-01-01

    Intracranial atherosclerotic disease (ICAD) is likely the most common cause of stroke worldwide and remains highly morbid even with highly monitored medical therapy. Recent results of the SAMMPRIS trial, which randomized patients to stenting plus aggressive medical management versus aggressive medical management alone have shown that additional treatment of intracranial atherosclerotic lesions with the Wingspan stent is inferior to aggressive medical management alone. In light of these results, there has been renewed interest in angioplasty alone to treat symptomatic ICAD. This article will briefly review the natural history of ICAD and discuss the possible future for endovascular treatment of ICAD with primary intracranial angioplasty in appropriately selected patients. PMID:24782816

  4. Ballonnen in zee = balloons as marine litter

    NARCIS (Netherlands)

    Franeker, van J.A.

    2008-01-01

    Releasing balloons seems harmless. However, remains of balloons, especially valves and ribbons are becoming a common and persistent type of marine litter found on beaches. Following Dutch Queens day 2007, large numbers of Dutch balloons were found in Normandy, France. Animals may become entangled in

  5. Simulating clefts in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank; Brakke, Kenneth

    2010-02-01

    The geometry of a large axisymmetric balloon with positive differential pressure, such as a sphere, leads to very high film stresses. These stresses can be significantly reduced by using a tendon re-enforced lobed pumpkin-like shape. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin shape, including the constant bulge angle (CBA) design, the constant bulge radius (CBR) design, CBA/CBR hybrids, and NASA’s recent constant stress (CS) design. Utilizing a hybrid CBA/CBR pumpkin design, Flight 555-NT in June 2006 formed an S-cleft and was unable to fully deploy. In order to better understand the S-cleft phenomenon, a series of inflation tests involving four 27-m diameter 200-gore pumpkin balloons were conducted in 2007. One of the test vehicles was a 1/3-scale mockup of the Flight 555-NT balloon. Using an inflation procedure intended to mimic ascent, the 1/3-scale mockup developed an S-cleft feature strikingly similar to the one observed in Flight 555-NT. Our analysis of the 1/3-scale mockup found it to be unstable. We compute asymmetric equilibrium configurations of this balloon, including shapes with an S-cleft feature.

  6. Global electrodynamics from superpressure balloons

    Science.gov (United States)

    Holzworth, R. H.; Hu, H.

    1995-01-01

    Electric field and conductivity measurements in the stratosphere between November 1992 and March 1993 have been made using superpressure balloons in the southern hemisphere. Over 400 payload-days of data have been made during a record setting experiment called ELBBO (Extended Life Balloon Borne Observatories). This experiment resulted in 4 flights aloft simultaneously for over 2 months including one flight which lasted over 4 months. Electrodynamical coupling between the atmosphere and ionosphere is studied using the measured electric fields, and a simple empirical model of the stratospheric conductivity. Altitude profiles of conductivity have been obtained from several superpressure balloon flights using the large end-of-flight altitude swings on the last few days of each flight (as the balloon begins to loose superpressure). Coupling between the fields and atmospheric inertial waves has been observed. Effects and dynamics of the global circuit suggest that standard models are missing significant phenomena. Large scale ionospheric convection activity has been studied from the polar cap to the middle latitudes. Cusp latitude fields have been continuously measured for many days in a row.

  7. Stability of the pumpkin balloon

    Science.gov (United States)

    Baginski, Frank

    A large axisymmetric balloon with positive differential pressure, e.g., a sphere, leads to high film stresses. These can be significantly reduced by using a lobed pumpkin-like shape re-enforced with tendons. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin-shape at full inflation, including the constant bulge angle (CBA) design and the constant bulge radius (CBR) design. The authors and others have carried out stability studies of CBA and CBR designs and found instabilities under various conditions. While stability seems to be a good indicator of deployment problems for large balloons under normal ascent conditions, one cannot conclude that a stable design will deploy reliably. Nevertheless, stability analysis allows one to quantify certain deployment characteristics. Ongoing research by NASA's Balloon Program Office utilizes a new design approach developed by Rodger Farley, NASA/GSFC, that takes into account film and tendon strain. We refer to such a balloon as a constant stress (CS) pumpkin design. In June 2006, the Flight 555-NT balloon (based on a hybrid CBR/CBA design) developed an S-cleft and did not deploy. In order to understand the S-cleft phenomena and study a number of aspects related to the CS-design, a series of inflation tests were conducted at TCOM, Elizabeth City, NC in 2007. The test vehicles were 27 meter diameter pumpkins distinguished by their respective equatorial bulge angles (BA). For example, BA98 indicates an equatorial bulge angle of 98° . BA90, BA55, and BA00 are similarly defined. BA98 was essentially a one-third scale version of of the Flight 555 balloon (i.e., 12 micron film instead of 38.1 micron, mini-tendons, etc.). BA90 and BA55 were Farley CS-designs. BA00 was derived from the BA55 design so that a flat chord spanned adjacent tendons. In this paper, we will carry out stability studies of BA98, BA90, BA55, and BA00. We discuss the deployment problem of pumpkin balloons in light of 2007 inflation

  8. Transcutaneous angioplasty of vertebral artery atheromatous ostial stricture

    International Nuclear Information System (INIS)

    The authors report experience of intravascular angioplasty of atheromatous ostial strictures of the vertebral artery in 24 patients. After reviewing the technique, they authive the indications provided through Doppler velocimetric data. The results seem to be encouraging as symptoms disappeared completely in 21 patients. (orig.)

  9. Percutaneous coronary angioplasty in a cardiac transplant recipient.

    OpenAIRE

    Gammage, M D; Shiu, M F; English, T A

    1988-01-01

    Two years after an orthotopic cardiac transplant a 28 year old man was found to have clinically significant stenosis of the right coronary artery at routine coronary angiography. This lesion was accompanied by a perfusion defect on exercise thallium scintigraphy. Percutaneous transluminal coronary angioplasty of the lesion improved the angiographic appearance of the stenosis and reduced the exercise thallium perfusion defect.

  10. A meta-analytic overview of thrombectomy during primary angioplasty

    NARCIS (Netherlands)

    Luca, G. De; Navarese, E.P.; Suryapranata, H.

    2013-01-01

    INTRODUCTION: Even though primary angioplasty restores TIMI 3 flow in more than 90% of STEMI patients, the results in terms of myocardial perfusion are still unsatisfactory in a relatively large proportion of patients. Great interest has been focused in the last years on distal embolization as major

  11. Subintimal angioplasty: predictors of long-term success.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2009-08-01

    To determine the clinical outcomes and success rates after percutaneous subintimal angioplasty (SIA) in patients with lower-limb occlusive lesions causing intermittent claudication (IC) or critical limb ischemia (CLI) at midterm to long-term follow-up. The secondary aim was to elicit factors predictive of a successful outcome.

  12. Early outcome of high energy Laser (Excimer) facilitated coronary angioplasty ON hARD and complex calcified and balloOn-resistant coronary lesions: LEONARDO Study

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosini, Vittorio; Sorropago, Giovanni; Laurenzano, Eugenio [Montevergine Clinic, Mercogliano (Italy); Golino, Luca, E-mail: lucagolino.jazz@alice.it [Montevergine Clinic, Mercogliano (Italy); Moriggia-Pelascini Hospital, Gravedona, Como (Italy); Casafina, Alfredo; Schiano, Vittorio [Montevergine Clinic, Mercogliano (Italy); Gabrielli, Gabriele [University Hospital Ospedali Riuniti, Ancona (Italy); Ettori, Federica; Chizzola, Giuliano [Spedali Civili University Hospital, Brescia (Italy); Bernardi, Guglielmo; Spedicato, Leonardo [University Hospital S. Maria Misericordia, Udine (Italy); Armigliato, Pietro [Istituto Italiano Ricerche Mediche, Verona (Italy); Spampanato, Carmine [Telethon Institute of Genetics and Medicine (TIGEM), Naples (Italy); Furegato, Martina [Istituto Italiano Ricerche Mediche, Verona (Italy)

    2015-04-15

    Aim: An innovative xenon–chlorine (excimer) pulsed laser catheter (ELCA X80) has been recently used for the treatment of complex coronary lesions, as calcified stenosis, chronic total occlusions and non-compliant plaques. Such complex lesions are difficult to adequately treat with balloon angioplasty and/or intracoronary stenting. The aim of this study was to examine the acute outcome of this approach on a cohort of patients with coronary lesions. Methods and Results: Eighty patients with 100 lesions were enrolled through four centers, and excimer laser coronary angioplasty was performed on 96 lesions (96%). Safety and effectiveness data were compared between patients treated with standard laser therapy and those treated with increased laser therapy. Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success in was obtained in 87 lesions (90.6%). There was no perforation, major side branch occlusion, spasm, no-reflow phenomenon, dissection nor acute vessel closure. Increased laser parameters were used successfully for 49 resistant lesions without complications. Conclusions: This study suggests that laser-facilitated coronary angioplasty is a simple, safe and effective device for the management of complex coronary lesions. Furthermore, higher laser energy levels delivered by this catheter improved the device performance without increasing complications. - Highlights: • We planned this multicenter study to examine the acute outcome of an innovative xenon–chlorine (excimer) pulsed laser catheter (ELCA X80) for treatment of complex coronary lesions. • We enrolled 80 patients with 100 lesions and performed excimer laser coronary angioplasty in 96 lesions (96%). • Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success was obtained in 87 lesions (90.6%). • Increased laser parameters were used successfully for 49 resistant

  13. Scientific ballooning in India: recent developments

    Science.gov (United States)

    Joshi, M. N.; Damle, S. V.

    The National Scientific Balloon Facility (NBF) of the Tata Institute of Fundamental Research (TIFR) has been conducting regular balloon flights for various experiments in the areas of Space Astronomy and Atmospheric Sciences. A continuous improvement in all aspects of Scientific Ballooning through a sustained R and D programme ensures uptodate services and a better handle on the design specifications for the balloon. Recent developments in balloon grade films, continuous improvements in design specifications, balloon manufacturing methods, flight operational procedures and improved balloon flight capabilities have resulted in a greatly improved flight performance in the last five years. A launch capability upgradation programme in terms of new launch spool and new launch vehicle has been initiated to be able to safely launch balloons with gross lifts upto 3500 kg, balloon volumes upto 450,000 m^3 and payloads upto 1400 kg. A series of steps have been initiated to improve long duration flight capabilities. In this paper, we present details on some of these aspects of Scientific Ballooning in India.

  14. A Mars 2011 Balloon Mission Trade Study

    Science.gov (United States)

    Smith, I.; Lew, T.; Perry, W.

    Mars Scouts are competitively selected PI-led missions to further Mars exploration in ways that satisfy NASA s overall objectives but are not currently in the planned line of missions The current 2006 Announcement of Opportunity AO for Mars Scouts has just closed The goal of this SwRI study was to develop a new balloon mission concept to where it could be credibly proposed for the AO The balloon system was defined in the study as consisting of two parts the balloon flight system BFS and the balloon deployment inflation system DIS The BFS includes the balloon envelope accessory hardware and gondola The balloon includes the envelope seams end fittings load core inflation tube diffusers payload tether shock attenuator and separation hardware The DIS includes the balloon container deployment hardware sequencer tankage gas and control hardware Trade studies were performed to better define the mission design space These studies included 1 effect of varied atmospheric thermal loads 2 effect of varying latitudes 3 effect of payload mass for varying altitudes 4 effect of radiative material properties on balloon size mass 5 effect of material areal densities on balloon size mass and 6 effect of inflation gas on system masses Results of the balloon trade study for the Mars 2011 mission opportunity will be presented

  15. Experimental Study of Adenovirus Vector Mediated-hVEGF165 Gene on Prevention of Restenosis after Angioplasty

    Institute of Scientific and Technical Information of China (English)

    刘启功; 陆再英; 岳远坤; 林立; 张卫东; 颜进

    2004-01-01

    This study evaluated the effects of adenovirus vector mediated human vascular endothelial growth factor-165 (hVEGF165) gene on prevention of restenosis after angioplasty. Rabbit models of bilateral carotid artery injury were established by balloon denudation. The recombinant adenoviruses containing hVEGF165 cDNA was directly injected into left side of the injured carotid arteries.On day 3 and week 3 after transfection the expression of VEGF was observed by RT-PCR and immunohistochemistry. The thrombokinesis, reendothelialization (rET) and intimal hyperplasia in carotid arteries were evaluated by computerized image analysis system 3 weeks after gene transfer.The changes in the VEGF gene-treated side were compared with the control side. Our results showed that 3 days and 3 weeks after hVEGF165 gene transfer the VEGF mRNA and antigen expression were detected in vivo. 3 weeks after the transfer, the carotid artery rET was markedly better in the VEGF gene-treated group compared with the control. The thrombokinesis, intima area/media area (I/M), maximal intimal and medial thicknesses (ITmax and MTmax) demonstrated a statistically significant decrease in arteries treated with VEGF gene as compared with the control group. It is concluded that VEGF gene transfer could be achieved by intra-arterial injection of recombinant adenoviruses. It might accelerate the restoration of endothelial integrity, inhibit thrombokinesis and attenuate intimal hyperplasia in the injured arteries after VEGF gene transfer. This procedure could be useful in preventing restenosis after angioplasty.

  16. Left main coronary stenosis as a late complication of percutaneous angioplasty:an old problem,but still a problem

    Institute of Scientific and Technical Information of China (English)

    Giuseppe Faggian; Gianluca Rigatelli; Francesco Santini; Giuseppe Petrilli; Paolo Cardaioli; Loris Roncon; Alessandro Mazzucco

    2009-01-01

    Objective Accelerated left main coronary stenosis (LMCS) is a known potential late complication of coronary artery catheter procedures. The aim of this study was to assess the current occurrence of LMCS as a delayed complication of percutaneous angioplasty (PTCA) of the left coronary branches in our institution. Methods The medical records of patients referred for coronary artery by-pass surgery from the same Cardiology Unit in the January 2003 to December 2006 period and presenting a significant (> 50%) LMCS as a new finding following a PTCA of the left coronary artery branches, were reviewed. Patients with retrospective evidence of any LMCS at previous coronary angiographies preceding the percutaneous procedure were excluded. Results Thirty-seven patients (5 females, mean age 71.1±8.6 years) out of 944 (4%) having undergone a PTCA, fulfilled the inclusion criteria, 19 (51%) after a procedure also involving the LAD coronary artery. Extraback-up guiding catheters were used in most cases. Use of multiple wires or balloons was observed in 3 cases (8%). Rotablator and proximal occlusion device were used in one case respectively (3%). Twenty patients (54%) have had more than one percutaneous coronary intervention on the left coronary branches. The mean time elapsed from the first angioplasty and surgical intervention was 18.1±7.8 months. Conclusions The potential occurrence of LMCS following a percutaneous intervention procedure, especially when complicated and repeated, should not be underestimated in the current era. This evidence may offer the rationale to schedule non-invasive imaging tests to monitor left main coronary patency after the procedure as well as to fuel further research to develop less traumatic materials.

  17. Viscoelastic behaviour of pumpkin balloons

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    2008-11-01

    The lobes of the NASA ULDB pumpkin-shaped super-pressure balloons are made of a thin polymeric film that shows considerable time-dependent behaviour. A nonlinear viscoelastic model based on experimental measurements has been recently established for this film. This paper presents a simulation of the viscoelastic behaviour of ULDB balloons with the finite element software ABAQUS. First, the standard viscoelastic modelling capabilities available in ABAQUS are examined, but are found of limited accuracy even for the case of simple uniaxial creep tests on ULDB films. Then, a nonlinear viscoelastic constitutive model is implemented by means of a user-defined subroutine. This approach is verified by means of biaxial creep experiments on pressurized cylinders and is found to be accurate provided that the film anisotropy is also included in the model. A preliminary set of predictions for a single lobe of a ULDB is presented at the end of the paper. It indicates that time-dependent effects in a balloon structure can lead to significant stress redistribution and large increases in the transverse strains in the lobes.

  18. Angioplasty and stent placement in chronic occlusion of the superficial femoral artery: technique and results.

    OpenAIRE

    Conroy, RM; Gordon, IL; Tobis, JM; Hiro, T; Kasaoka, S; Stemmer, EA; Wilson, SE

    2000-01-01

    PURPOSE: To improve the patency rate for angioplasty in chronic occlusion of the superficial femoral artery by deploying stents after angioplasty. MATERIALS AND METHODS: Angioplasty and stent placement were performed in 61 arteries in 48 male patients. The mean occlusion length was 13.5 cm and the mean stent length was 30 cm. Patency rates were analyzed at 6 months and at 1, 2, 3, and 4 years. The predictors of restenosis were analyzed by univariate and multiple logistic regression. RESULTS: ...

  19. Deep arterial injury during experimental angioplasty: relation to a positive indium-111-labeled platelet scintigram, quantitative platelet deposition and mural thrombosis

    International Nuclear Information System (INIS)

    Although it is not clear why coronary occlusion and restenosis occur after successful coronary angioplasty, factors related to the procedure may influence early and late results. The possible adverse effects of a medial tear documented histologically and produced during balloon angioplasty of the common carotid arteries were studied in 30 fully heparinized (100 U/kg body weight) normal pigs. Scanning electron microscopy showed endothelial denudation and extensive platelet deposition in all dilated arterial segments. Visible macroscopic mural thrombus was present within an hour of the procedure in 29 (91%) of the 32 arteries that had a medial tear documented by histologic study; the tear produced an indium-111-labeled platelet deposition of 116.4 +/- 26.5 X 10(6)/cm2 (mean +/- SE) and total thrombotic occlusion in 2 arteries (4%). None of the 24 arteries without a medial tear had a thrombus, and the mean platelet deposition in that group was 7.0 +/- 0.5 X 10(6)/cm2 (p less than 0.0008). In 12 pigs scanned with a gamma camera, visible thrombus was associated with platelet deposition in excess of 20 X 10(6)/cm2 in 12 arteries, 9 of which had a positive indium-111-labeled platelet scintigram. Thus, arterial angioplasty causes deep arterial injury, which appears to be a major cause of mural thrombosis, heavy platelet deposition, a positive indium-111-labeled platelet scintigram and acute arterial occlusion. A positive indium-111-labeled platelet scintigram was always associated with macroscopic thrombus of at least 20 > 10(6) platelets/cm2 and underlying deep arterial injury

  20. Below knee angioplasty in elderly patients: Predictors of major adverse clinical outcomes.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2011-03-01

    To determine predictors of clinical outcome following percutaneous transluminal angioplasty (PTA) in elderly patients with below knee atherosclerotic lesions causing intermittent claudication (IC) or critical limb ischaemia (CLI).

  1. Basic study of effects on the smooth muscle cells' proliferation with novel short-term thermal angioplasty in vitro and in vivo

    Science.gov (United States)

    Kunio, M.; Shimazaki, N.; Ito, A.; Hayashi, T.; Arai, T.; Sakurada, M.

    2011-03-01

    We investigated the effect on smooth muscle cells' proliferation with stretch-fixing in both in vitro and in vivo porcine study to determine the optimum heat condition of novel short-term thermal angioplasty, Photo-thermo Dynamic Balloon Angioplasty (PTDBA). With PTDBA, we have obtained the sufficient arterial dilatation by short-term heating (< 15 s, < 70 °C) and low dilatation pressure (< 0.4 MPa) without excessive neo-intimal hyperplasia on chronic phase. The smooth muscle cells were found to be fixed with stretched shape in vascular wall after PTDBA in vivo. The deformation rate of smooth muscle cells' nuclei was 1.6 +/- 0.1 after PTDBA (15 s, 65 °C, 0.35 MPa). The smooth muscle cells, which were extracted from porcine arteries, were cultured on the specially designed equipment to give stretch-fixing stimulus in vitro. The cell proliferation was inhibited at 20 % stretching compared to 15 % stretching significantly (p < 0.05). The immunostaining specimens of basic Fibroblast Growth Factor (bFGF) and its receptor FGFR-1 were made from the porcine arteries in vivo. We found that the expressions of bFGF and FGFR-1 in the media were not observed after PTDBA. We think that these results suggested the possibility for the inhibition of the excessive cell proliferation after PTDBA.

  2. Early Results with the Use of Heparin-bonded Stent Graft to Rescue Failed Angioplasty of Chronic Femoropopliteal Occlusive Lesions: TASC D Lesions Have a Poor Outcome

    Energy Technology Data Exchange (ETDEWEB)

    Kuhan, Ganesh, E-mail: gkuhan@nhs.net; Abisi, Said; Braithwaite, Bruce D.; MacSweeney, Shane T. R. [Nottingham University Hospitals, Vascular and Endovascular Unit, Queens Medical Centre (United Kingdom); Whitaker, Simon C.; Habib, Said B. [Nottingham University Hospitals, Department of Radiology, Queen' s Medical Centre (United Kingdom)

    2012-10-15

    Purpose: To evaluate early patency rate of the heparin-bonded stent grafts in atherosclerotic long femoropopliteal occlusive disease, and to identify factors that affect outcome. Methods: Heparin-bonded Viabahn stent grafts were placed in 33 limbs in 33 patients during 2009-2010. The stents were deployed to rescue failed conventional balloon angioplasty. Mean age was 69 (range 44-88) years, and 67 % (22 of 33) were men. Most procedures (21 of 33, 64 %) were performed for critical limb ischemia (33 % for rest pain, 30 % tissue loss). Kaplan-Meier plots and Cox regression analysis were used to identify significant risk factors. Results: The average length of lesions treated was 25 {+-} 10 cm, and they were predominantly TASC (Transatlantic Intersociety Consensus) D (n = 13) and C (n = 17) lesions. The median primary patency was 5.0 months (95 % confidence interval 1.22-8.77). The mean secondary patency was 8.6 months (95 % confidence interval 6.82-10.42). Subsequently, 4 patients underwent bypass surgery and 5 patients underwent major amputation. One patient died. There were 5 in-stent or edge-stent stenoses. Cox multivariate regression analysis identified TASC D lesions to be a significant risk factor for early occlusion (p = 0.035). Conclusion: TASC D lesions of femoropopliteal occlusions have poor patency rates with the use of heparin-bonded stent grafts after failed conventional angioplasty. Alternative options should be considered for these patients.

  3. The Case for Angioplasty in Patients with Symptomatic Intracranial Atherosclerosis

    Directory of Open Access Journals (Sweden)

    Ryan A Mctaggart

    2014-04-01

    Full Text Available Intracranial atherosclerotic disease (ICAD is likely the most common cause of stroke worldwide and remains highly morbid even with highly monitored medical therapy. Recent results of the SAMMPRIS trial which randomized patients to stenting plus aggressive medical management versus aggressive medical management alone have shown that additional treatment of intracranial atherosclerotic lesions with the Wingspan stent is inferior to aggressive medical management alone. In light of these results there has been renewed interest in angioplasty alone to treat symptomatic ICAD. This article will briefly review the natural history of intracranial atherosclerotic disease (ICAD and discuss the possible future for endovascular treatment of ICAD with primary intracranial angioplasty in appropriately selected patients.

  4. Hyperspectral Polarimeter for Monitoring Balloon Strain Project

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's latest generation of superpressure, ultra long duration balloons (ULDB) extend the flight time for stratospheric experiments to levels previously...

  5. Scientific Ballooning Activities and Recent Developments in Technology and Instrumentation of the TIFR Balloon Facility, Hyderabad

    Science.gov (United States)

    Buduru, Suneel Kumar

    2016-07-01

    The Balloon Facility of Tata Institute of Fundamental Research (TIFR-BF) is a unique center of expertise working throughout the year to design, fabricate and launch scientific balloons mainly for space astronomy, atmospheric science and engineering experiments. Recently TIFR-BF extended its support to new user scientists for conducting balloon launches for biological and middle atmospheric sciences. For the first time two balloon launches conducted for sending live lab rats to upper stratosphere and provided launch support for different balloon campaigns such as Tropical Tropopause Dynamics (TTD) to study water vapour content in upper tropospheric and lower stratospheric regions over Hyderabad and the other balloon campaign to study the Asian Tropopause Aerosol Layer (BATAL) during the Indian summer monsoon season. BATAL is the first campaign to conduct balloon launches during active (South-West) monsoon season using zero pressure balloons of different volumes. TIFR-BF also provided zero pressure and sounding balloon support to various research institutes and organizations in India and for several international space projects. In this paper, we present details on our increased capability of balloon fabrication for carrying heavier payloads, development of high strength balloon load tapes and recent developments of flight control and safety systems. A summary of the various flights conducted in two years will be presented along with the future ballooning plans.

  6. [Changes in left ventricular dP/dt during transluminal coronary angioplasty].

    Science.gov (United States)

    Crochet, D; Petitier, H; Grossetête, R

    1985-03-01

    The authors studied changes of LV dP/dt during transcutaneous coronary angioplasty (TCA). The aim of the study was to detect the alterations of LV function during coronary occlusion and to evaluate the immediate effects of PCA on myocardial function. Six patients with incapacitating angina and isolated left anterior descending disease were successfully treated by TCA using Gruntzig's technique. The study protocol included several recording sequences per patient during the phases of balloon inflation at progressively increasing pressures from 2 to 10 hours. Each sequence comprised a recording under basal conditions and every 5 seconds during inflation (20 seconds) and deflation (45 seconds) of the following parameters: heart rate, aortic and LV pressures, positive and negative peaks of LV dP/dt, and the intracoronary pressure gradient at the beginning and the end of each sequence. The first part of the results based on 27 recorded sequences analysed the bad effects of myocardial ischaemia; coronary occlusion induced a significant fall (p less than 0.01) in the positive and negative peak dP/dt values and on elevation (p less than 0.01) in LV end diastolic pressure, without affecting LV systolic pressure or heart rate. These changes have the following characteristics: they are early, occurring within seconds of coronary occlusion; they affect LV contraction and relaxation simultaneously, but the effects are more marked on LV relaxation; the severity is proportional to the duration of occlusion; they are totally reversible; the disturbances of relaxation return to normal more quickly than those of contraction.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Efficacy of Drug-Eluting Balloons for Patients With In-Stent Restenosis: A Meta-Analysis of 8 Randomized Controlled Trials.

    Science.gov (United States)

    Gao, Shen; Shen, Jing; Mukku, Venkata Kishore; Wang, Mei Jia; Akhtar, Muzina; Liu, Wei

    2016-08-01

    The optimal treatment for in-stent restenosis (ISR) of both bare-metal stent (BMS) and drug-eluting stent (DES) is currently unclear. The aim of this meta-analysis was to assess the role of drug-eluting balloon (DEB) as an optional treatment for ISR. We searched PubMed, MEDLINE, EMBASE, BIOS, and Web of Science from 2005 to July 2014. Eight studies, enrolling 1413 patients were included. Main end points were late lumen loss (LLL), binary in-segment restenosis (BR), major adverse cardiac events (MACEs), target lesion revascularization (TLR), death, myocardial infarction (MI), and stent thrombosis (ST). When compared to plain old balloon angioplasty (POBA), DEB treatment significantly reduced the risk of MACE (risk rato [RR] 0.37, P option to treat ISR when compared to POBA. However, it had similar effects as DES. PMID:26483569

  8. Paclitaxel-Coated Balloons: Review of a Promising Interventional Approach to Preventing Restenosis in Femoropopliteal Arteries.

    Science.gov (United States)

    Teleb, Mohamed; Wardi, Miraie; Gosavi, Sucheta; Said, Sarmad; Mukherjee, Debabrata

    2016-06-01

    Peripheral arterial disease (PAD), a major cause of morbidity and mortality worldwide, is characterized by intermittent claudication and is associated with chronic diseases such as diabetes and hypertension. The goal of treatment is to address the underlying cause and to modify risk factors. Although medical management is the first-line treatment of PAD, some individuals may have severe symptoms and require revascularization with percutaneous transluminal angioplasty with or without stent placement or surgery. Interventional approaches may, however, be associated with high prevalence of restenosis and subsequent complications such as critical limb ischemia and amputation. Drug-eluting balloons (DEBs) are a new interventional technology with the primary goal of preventing restenosis. We review the clinical trials and studies that assessed the efficacy and safety profile of DEB and will focus on the restenosis rate in femoropopliteal arteries including target lesion revascularization (TLR) and late lumen lesion (LLL) using different modalities of intervention such as stents and DEB. Average data collected from the trials reported included restenosis rate of 25%, 0.3 mm LLL, and 14% reduction in TLR with DEB versus uncoated balloons. Below the knee (BTK) only intervention studies were excluded from this review as endovascular approach is usually reserved for critical limb ischemia for BTK disease. Interventional approach to treat PAD with DEB appears to be a promising technology. Additional larger studies are needed to further define safety, efficacy, and longer term outcome with this novel technology.

  9. Angioplasty alone versus angioplasty and stenting for subclavian artery stenosis--a systematic review and meta-analysis.

    Science.gov (United States)

    Chatterjee, Saurav; Nerella, Nishant; Chakravarty, Saneka; Shani, Jacob

    2013-01-01

    Subclavian artery stenosis has long been treated with great success with bypass surgery. Percutaneous intervention, often used in combination with stent placement, has come into vogue for the past few years as a safe and effective therapeutic modality. This study aimed to compare angioplasty alone with angioplasty followed by stent placement by combining available data. The objective of this study was to perform a review of the available literature to compare the efficacy of percutaneous transluminal angioplasty (PTA) alone with PTA followed by stent placement for proximal subclavian artery stenosis. Successful recanalization was defined as patency at the end of 1 year, and reocclusions and restenoses were noted as events for the purpose of pooling the data. The authors searched the Specialized Register and the Cochrane Central Register of Controlled Trials (CENTRAL) in The Cochrane Library, PubMed, EMBASE, and CINAHL databases for relevant trials/studies comparing PTA and PTA with stenting. Review authors independently assessed the methodological quality of studies (focusing on the adequacy of the randomization process, allocation concealment, blinding, completeness of follow-up, and intention-to-treat analysis) and selected studies for inclusion. All retrospective observational studies were also included in the analysis in the absence of double-blinded randomized trials for increasing sample size. All analyses were done using RevMan 5.0. Odds ratio was calculated using Mantel-Haenszel test with a fixed effect model. All included studies were assessed by all authors for potential sources of bias. Eight studies were included in the analysis having 544 participants. Stenting after PTA was significantly superior to angioplasty alone for treatment of subclavian artery stenosis and maintenance of patency at 1 year, as indicated by absence of events (P = 0.004; 95% confidence interval, odds ratio 2.37 [1.32-4.26]) without significant complication rates for either

  10. Promising role of drug-coated balloons in the tibial vessels?

    Science.gov (United States)

    Langhoff, Ralf; Behne, Andrea; Buschmann, Eva

    2016-10-01

    In order to assess the role of drug-coated balloons (DCB) in below-the-knee (BTK) artery interventions, we analyzed randomized trials which compare coated to non-coated balloons and additionally a direct comparison of drug-eluting stents (DES) with DCB. As angioplasty with non-coated balloons is per guideline-recommendation still standard of care for below-the-knee artery endovascular treatment, we focused on the direct comparison of efficacy and clinical outcome data of both treatment modalities. Data from peer reviewed and published trials were consulted. For each single study, primary and secondary endpoints were reported and compared. Three single-center, non-core lab adjudicated trials showed encouraging data which suggests that DCB in BTK arteries effectively inhibit the risk of early restenosis, but the pivotal, prospectively randomized, multicenter, core lab adjudicated trials failed to match with these result. Limitations of DEB treatment and trials in BTK arteries had been reported, hence a technical evaluation of possible side effects of DCB treatment and of trial design was taken into account. On the basis of the results available, the distinguishing findings of drug eluting effects in the femoropopliteal region cannot be transferred to BTK arteries. Refinement of the existing DCB technology and of future trial design should be considered. To adjudicate on DCB technology applied for BTK treatment is premature and it is mandatory to be kept under evaluation, because the potential benefit, with respect to the compelling results in the femoropoliteal arteries, could be huge to improve endovascular BTK and especially CLI treatment. PMID:27465390

  11. Emergency endovascular repair of iliac artery rupture caused by post-stenting angioplasty with an endograft

    Institute of Scientific and Technical Information of China (English)

    ZHOU Yu-bin; WU Dan-ming; XU Ke; WANG Cheng-gang; YI Wei; JIA Qi; SUN Yu-xin

    2007-01-01

    @@ Iliac artery rupture is a rare complication of poststenting angioplasty and can lead to massive lifethreatening haemorrhage. Conventional surgery can not repair the damaged vessel easily and may cause substantial blood loss and high operative morbidity and mortality. We report our experience with a selfexpanding covered endoprosthesis for endovascular repair of the rupture of an iliac artery caused by stenting angioplasty.

  12. Percutaneous transluminal angioplasty of the superficial femoral artery by retrograde catheterization via the popliteal artery

    DEFF Research Database (Denmark)

    Tønnesen, K H; Sager, P; Karle, A;

    1988-01-01

    We report the results of 50 angioplasty procedures via the popliteal artery. A 3-year follow-up including control of blood pressures at ankle and toe levels show results comparable to reports in the literature. This new approach for angioplasty of the superficial femoral artery and eventually...

  13. The Dutch experience in percutaneous transluminal angioplasty of narrowed saphenous veins used for aortocoronary arterial bypass

    NARCIS (Netherlands)

    W.H.T. Plokker; H.J. Meester (Hannie); P.W.J.C. Serruys (Patrick)

    1991-01-01

    textabstractOf 19,994 percutaneous transluminal coronary angioplasty procedures performed in The Netherlands between April 1980 and January 1989, the long-term follow-up of 454 patients who underwent angioplasty of greater than or equal to 1 saphenous vein bypass graft was reviewed. In 46% of patien

  14. Impact of Diabetes on Long-Term Outcome After Primary Angioplasty

    DEFF Research Database (Denmark)

    De Luca, Giuseppe; Dirksen, Maurits T; Spaulding, Christian;

    2012-01-01

    Diabetes has been shown to be associated with worse survival and repeat target vessel revascularization (TVR) after primary angioplasty. The aim of the current study was to evaluate the impact of diabetes on long-term outcome in patients undergoing primary angioplasty treated with bare metal stents...

  15. A COMPARISON OF HIRUDIN WITH HEPARIN IN THE PREVENTION OF RESTENOSIS AFTER CORONARY ANGIOPLASTY

    NARCIS (Netherlands)

    SERRUYS, PW; HERRMAN, JPR; SIMON, R; RUTSCH, W; BODE, C; LAARMAN, GJ; VANDIJK, R; VANDENBOS, AA; UMANS, VAWM; FOX, KAA; CLOSE, P; DECKERS, JW

    1995-01-01

    Background. The likelihood of restenosis is a major limitation of coronary angioplasty. We studied whether hirudin, a highly selective inhibitor of thrombin with irreversible effects, would prevent restenosis after angioplasty. We compared two regimens of recombinant hirudin with heparin. Methods. W

  16. Impact of diabetes on long-term outcome after primary angioplasty: insights from the DESERT cooperation

    NARCIS (Netherlands)

    Luca, G. De; Dirksen, M.T.; Spaulding, C.; Kelbaek, H.; Schalij, M.; Thuesen, L.; Hoeven, B. van der; Vink, M.A.; Kaiser, C.; Musto, C.; Chechi, T.; Spaziani, G.; Llera, L.S. Diaz de la; Pasceri, V.; Lorenzo, E. Di; Violini, R.; Suryapranata, H.; Stone, G.W.; cooperation, D.

    2013-01-01

    OBJECTIVE: Diabetes has been shown to be associated with worse survival and repeat target vessel revascularization (TVR) after primary angioplasty. The aim of the current study was to evaluate the impact of diabetes on long-term outcome in patients undergoing primary angioplasty treated with bare me

  17. The protective effect of bergamot oil extract on lecitine-like oxyLDL receptor-1 expression in balloon injury-related neointima formation.

    Science.gov (United States)

    Mollace, Vincenzo; Ragusa, Salvatore; Sacco, Iolanda; Muscoli, Carolina; Sculco, Francesca; Visalli, Valeria; Palma, Ernesto; Muscoli, Saverio; Mondello, Luigi; Dugo, Paola; Rotiroti, Domenicantonio; Romeo, Francesco

    2008-06-01

    Lectin-like oxyLDL receptor-1 (LOX-1) has recently been suggested to be involved in smooth muscle cell (SMC) proliferation and neointima formation in injured blood vessels. This study evaluates the effect of the nonvolatile fraction (NVF), the antioxidant component of bergamot essential oil (BEO), on LOX-1 expression and free radical generation in a model of rat angioplasty. Common carotid arteries injured by balloon angioplasty were removed after 14 days for histopathological, biochemical, and immunohistochemical studies. Balloon injury led to a significant restenosis with SMC proliferation and neointima formation, accompanied by increased expression of LOX-1 receptor, malondialdehyde and superoxide formation, and nitrotyrosine staining. Pretreatment of rats with BEO-NVF reduced the neointima proliferation together with free radical formation and LOX-1 expression in a dose-dependent manner. These results suggest that natural antioxidants may be relevant in the treatment of vascular disorders in which proliferation of SMCs and oxyLDL-related endothelial cell dysfunction are involved.

  18. Reevaluation of the balloon in gastrointestinal manometry.

    Science.gov (United States)

    Wilkes, P R; Hoskin, R W; Semlacher, E A; MacCannell, K L; Tyberg, J V

    1994-09-01

    Although the flow-through catheter (FTC) system has been useful and satisfactorily accurate for gastrointestinal manometry, we hypothesized that a cylindrical, liquid-filled balloon would also accurately reflect stress imposed by a sphincter. Latex balloons were fitted over the side ports of a closed-end catheter. The responses of the balloon and FTC system were compared in a cylindrical chamber commonly identified as a Starling resistor. Independent, constant-pressure sources were used to control both the inwardly directed "contact pressure" of the Starling resistor (Ps) and the intraluminal fluid pressure (P(lum)). The balloon transducers responded linearly and accurately (slope = 1) to changes in both Ps and P(lum) within the test range (0-200 mmHg, 0-26.7 kPa). When either P(lum) or Ps was held constant and the other changed, the balloon transducers always accurately measured the higher of the two pressures. Although the performance of the FTC system was improved after the Starling resistor was lubricated, the FTC system sometimes responded inaccurately to changes in Ps. The ability of the balloon transducers to measure the contractions of the lower esophageal sphincter and of the esophagus was demonstrated. We conclude that the balloon transducer can measure sphincter pressure accurately and suggest that, in certain circumstances, it might be advantageous relative to the FTC system. PMID:7842396

  19. The patients' perception of recovery after coronary angioplasty.

    Science.gov (United States)

    Higgins, M; Dunn, S; Theobald, K

    2000-08-01

    Coronary angioplasty and stent placement is associated with short hospital stays. Patients are expected to recover at home, alone, following limited care time with nurses. The purpose of the study was to describe participants' perceptions of recovery after angioplasty. Eight men and three women were interviewed 1 month after discharge from hospital. Verbatim transcripts were analysed for major themes using the qualitative techniques of grounded theory. Data analysis revealed three major categories: awareness of the problem, coping response and appraisal of the situation. These were linked via a problem solving process. In step one, the problem was identified. In step two, coping responses were taken to try and solve the problem. In step three, the results of the coping responses were appraised or evaluated. These categories were further defined by four phases identified as: pre-admission, admission, during the angioplasty and recovery. This paper describes the recovery phase. Awareness of the problem in the recovery phase was associated with 'relief from chest pain' for most participants. In contrast, anxiety continued and was associated with 'uncertainty over future health'. Participants described coping responses of "taking control of their life again" by undertaking both physical and psychological strategies. Finally, the situation was appraised to be either a 'good' or a 'bad' recovery. This appraisal was based on such considerations as the absence of chest pain, improvement in well-being and energy levels. The results of this study highlight patients' concerns and support the need for greater emphasis on their psychosocial needs. This care must be provided within the time constraints of short hospital stays. Nurses must also consider providing support to patients in the pre-admission and recovery phases.

  20. Transradial approach for coronary angioplasty in Chinese elderly patients

    Institute of Scientific and Technical Information of China (English)

    CAO Zheng; ZHOU Yu-jie; ZHAO Ying-xin; LIU Yu-yang; SHI Dong-mei; GUO Yong-he; CHENG Wan-jun; NIE Bin; WANG Jian-long

    2008-01-01

    Background The radiaI artery is currently regarded as a useful vascular access site for coronary procedures.This study was conducted to investigate the feasibility and safety of the percutaneous radial artery approach for angioplasty in the elderly.Methods Two thousand and fifty-eight consecutive patients (762 elderly,age≥65 years;and 1296 non-elderly,age <65 years,respectively) who underwent transradial coronary angioplasty were recruited in this study.Study endpoints included procedure success rate,procedure time,vascular complications at access site,and major adverse cardiac and cerebrovascular events during hospitalization.Results Elderly patients were more likely to present with unstable angina and renal dysfunction.The incidence of radial and brachiocephalic trunk anatomical tortuosity was higher in elderly patients than that in non-elderly patients (11.5% vs 3.7%;8.9% vs 2.6%,P<0.01,respectively).However,procedural success rate(94.7% vs 95.6%)and total mean procedure time ((67.9±27.3)minutes vs (58.6±38.5) minutes) for transradial coronary angioplasty were not significantly different between the two groups.Clinical course during the hospitalization was slightly worse in the elderly patients because of more adverse cardiac and cerebrovascular events after the procedure.However,the incidence of vascular complications was not significantly different between the elderly and non-elderly patients.Conclusion Although the incidence of radial and brachiocephalic trunk anatomical tortuosity is higher in elderly patients,transradial coronary intervention can be performed with similar safety and procedural success in these patients as compared with non-elderly patients.

  1. Carotid angioplasty and stent placement for restenosis after endarterectomy

    Energy Technology Data Exchange (ETDEWEB)

    Kadkhodayan, Yasha [Washington University School of Medicine, Interventional Neuroradiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Moran, Christopher J.; Cross, DeWitte T. [Washington University School of Medicine, Interventional Neuroradiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurological Surgery, St. Louis, MO (United States); Derdeyn, Colin P. [Washington University School of Medicine, Interventional Neuroradiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurological Surgery, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurology, St. Louis, MO (United States)

    2007-04-15

    Recurrent carotid stenosis following endarterectomy is a common complication, and reoperation may be associated with increased morbidity. The goal of this study was to determine the procedural safety and long-term complication rates of carotid angioplasty and stenting for recurrent stenosis. Of 248 consecutive carotid angioplasty and/or stenting procedures performed at our institution between March 1996 and November 2005, 83 procedures for recurrent stenosis following endarterectomy were performed in 75 patients (mean age 68 years; 43 men, 32 women) without cerebral protection devices. The patients' medical records were retrospectively reviewed for vascular imaging reports and available clinical follow-up. Procedural and long-term complication rates were calculated. Recurrent stenosis was reduced from a mean of 80.6% to no significant stenosis in 82 of 83 procedures. The procedural stroke rate was 3 out of 83 procedures (3.6%). The procedural transient ischemic attack (TIA) rate was 2 out of 83 procedures (2.4%). Mean follow-up was 22.4 months (range 0.1 to 86.7 months) with at least 6 months follow-up for 54 of 83 procedures (65%). There were five TIAs and no strokes on follow-up (new TIAs at 25.5 and 43.4 months; recurrent TIAs at 1, 11.1, and 12 months, all with normal angiograms). The composite 30-day stroke, myocardial infarction, or death rate was 5 of 83 procedures (6.0%). In this series, angioplasty and stenting were effective in relieving stenosis secondary to recurrent carotid disease after endarterectomy, and have low rates of ischemic complications. (orig.)

  2. Who is responsible for the consequences? A case of stent thrombosis subsequent to noncompliance with post angioplasty treatment regimen.

    Science.gov (United States)

    Sajwani, Salma Abdul Aziz; Allana, Saleema

    2014-01-01

    Coronary artery disease (CAD) is a major cause of mortality internationally and in Pakistan. Angioplasty has been proven to be an effective treatment for CAD. Stent thrombosis is a known but preventable complication of angioplasty. Several factors may lead to stent thrombosis with non-compliance with the prescribed drug regimen, being one of the most important factors. We report a case of stent thrombosis after four months of angioplasty. After exploring of patient's post angioplasty routines, it was found that the patient was non-compliant with the prescribed anti- platelets and other prescribed drugs. This time the patient presented with another acute myocardial infarction, and he went through angioplasty again.

  3. Airborne Internet Providing Tethered Balloon System

    Directory of Open Access Journals (Sweden)

    Suvriti Dhawan1

    2015-12-01

    Full Text Available In this paper we shall introduce a new system for providing wireless network communication over a specified area using ’lighter than air’ balloons. This technology will replace the existing fiber optic network system. This will be done by using a tethered balloon along with the payload (containing a receiver, a transmitter and a radio communication device.This payload will be suspended from the ground at an altitude (depending on the area of coverage required. Users under this area will be able to access this system directly for internet connectivity. This system can be used over large areas like universities, companies and societies to provide internet facility to their users through Wi-Fi or over an area where the user is specified (commercial purposes. Currently Google is working on similar idea called the ’Google Loon’ in which they use high altitude balloons which float at an altitude twice as high as air planes and the weather. They recently tested this system over New-Zealand by providing internet to their pilot testers on ground. Their balloons not being stationary, move with directional winds and have to be replaced one after the other to maintain consistency. This can be a huge problem over the areas where upper atmospheric winds are not in favorable direction. We can resolve this problem by using our stationary tethered balloon system which can communicate with the loon balloons to provide internet facility over a desired area. Moreover when our balloon will communicate with the loon balloon it will increase the coverage area as the loon balloon has to communicate to a point which is above the ground. Our system will not only replace the existing fiber optic system but it will also be selfsustaining i.e. It will generate its own power using solar panels.

  4. Risk assessment after coronary angioplasty with SPECT myocardial perfusion studies

    International Nuclear Information System (INIS)

    The chest pain can be use for stratifying the risk of the patients after coronary angioplasty. Nevertheless this strategy has shown to have a low accuracy in the detection of restenosis and myocardial ischemia. Aims: To establish the usefulness of the SPECT studies in the risk stratification after the coronary angioplasty. Evaluate the incidence of silent ischemia or symptomatic, and its impact on the prognosis. Method: There were included 107 patients (p) submitted to a gated SPECT between the year of the coronary angioplasty. The analysis of the images was performed according to different scores (SSS, SRS, SDS). These data was correlated with the symptoms of the patients. We define group 1 (G1) as the asymptomatic without ischemia (n 59p), group 2 (G2) as silent ischemia (n = 28p) and group 3 (G3) as symptomatic with ischemia (n = 20p). A clinical follow-up was done in search of events (target vessel revascularization, unstable angina, AMI and death). Results: Significant differences were not observed in the clinical variables between the different groups. The SSS was lower in the G1 compare with G2 and G3 (p 0.0001) and was similar between the last two, p = NS (SSS: G1: 2.2 ± 4.9; G2: 7.6 ± 5.9; G3: 9.5 ± 6.8). The SDS was greater in G3 vs. G1 and G2, p = 0.0001, and greater in G2 vs. G1, p = 0.0001 (SDS: G1: 0; G2: 4.8 ± 3.5; G3: 7.2 ± 6.5). No differences where observed in the SRS between the three groups. In the follow-up the total percentage of events was lesser when compare the G1 with the G2 and G3 (G1: 3.3%; G2 and G3: 18.7%; p 0.02). The percentage of annual events of the G3 symptomatic with ischemia (11.03%) and G2 silent ischemia (4.04%) did not present differences (p 0.7). When the events of the G2 (4.04%) were compared with the G1 (1.24%) we observed a trend to major frequency of events in the G2 (p = 0.6). Conclusions: The presence of myocardial ischemia after coronary angioplasty is a determinant of the prognosis. Nevertheless, the extension

  5. Successful angioplasty during pregnancy for renal artery stenosis.

    Science.gov (United States)

    Margueritte, François; Velasco, Stephane; Pourrat, Olivier; Pierre, Fabrice

    2016-03-01

    Renal artery stenosis can be diagnosed during pregnancy and treated at the same time. A 30-year-old woman had a sudden, severe but asymptomatic hypertensive crisis at 21 weeks of gestation. The diagnosis of renal artery stenosis suspected on Doppler ultrasonography was confirmed and treated by renal angioplasty, which reduced her blood pressure. At 27 weeks of gestation, her blood pressure increased again, associated with significant proteinuria, suggesting pre-eclampsia. A cesarean section was performed giving birth to a healthy 940-g child. Renal artery stenosis should be considered when sudden and early-onset hypertension appears during pregnancy.

  6. Accurate Determination of the Volume of an Irregular Helium Balloon

    Science.gov (United States)

    Blumenthal, Jack; Bradvica, Rafaela; Karl, Katherine

    2013-01-01

    In a recent paper, Zable described an experiment with a near-spherical balloon filled with impure helium. Measuring the temperature and the pressure inside and outside the balloon, the lift of the balloon, and the mass of the balloon materials, he described how to use the ideal gas laws and Archimedes' principal to compute the average molecular…

  7. Investigating Diffusion and Entropy with Carbon Dioxide-Filled Balloons

    Science.gov (United States)

    Jadrich, James; Bruxvoort, Crystal

    2010-01-01

    Fill an ordinary latex balloon with helium gas and you know what to expect. Over the next day or two the volume will decrease noticeably as helium escapes from the balloon. So what happens when a latex balloon is filled with carbon dioxide gas? Surprisingly, carbon dioxide balloons deflate at rates as much as an order of magnitude faster than…

  8. Successful technical and clinical outcome using a second generation balloon expandable coronary stent for transplant renal artery stenosis: Our experience.

    Science.gov (United States)

    Salsamendi, Jason; Pereira, Keith; Baker, Reginald; Bhatia, Shivank S; Narayanan, Govindarajan

    2015-10-01

    Transplant renal artery stenosis (TRAS) is a vascular complication frequently seen because of increase in the number of renal transplantations. Early diagnosis and management is essential to optimize a proper graft function. Currently, the endovascular treatment of TRAS using angioplasty and/or stenting is considered the treatment of choice with the advantage that it does not preclude subsequent surgical correction. Treatment of TRAS with the use of stents, particularly in tortuous transplant renal anatomy presents a unique challenge to an interventional radiologist. In this study, we present three cases from our practice highlighting the use of a balloon-expandable Multi-Link RX Ultra coronary stent system (Abbott Laboratories, Abbott Park, Illinois, USA) for treating high grade focal stenosis along very tortuous renal arterial segments. Cobalt-Chromium alloy stent scaffold provides excellent radial force, whereas the flexible stent design conforms to the vessel course allowing for optimal stent alignment. PMID:26629289

  9. Looners: Inside the world of balloon fetishism

    OpenAIRE

    McIntyre, Karen E

    2011-01-01

    In the spring of 1997, Shaun had just broken up with a boyfriend, and his roommate had moved out. Living alone for the first time and relieved of the fear that someone might walk in the door, he was finally able to indulge his fantasy. The young man sat on his couch and started blowing up balloons. Shaun had loved playing with balloons since he was a child. When he hit puberty, he felt his first orgasm rubbing against a balloon. It was then that his relationship with the object took ...

  10. The balloon and the airship technological heritage

    Science.gov (United States)

    Mayer, N. J.

    1981-01-01

    The balloon and the airship are discussed with emphasis on the identification of commonalities and distinctions. The aerostat technology behind the shape and structure of the vehicles is reviewed, including a discussion of structural weight, internal pressure, buckling, and the development of a stable tethered balloon system. Proper materials for the envelope are considered, taking elongation and stress into account, and flight operation and future developments are reviewed. Airships and tethered balloons which are designed to carry high operating pressure with low gas loss characteristics are found to share similar problems in low speed flight operations, while possessing interchangeable technologies.

  11. Stratospheric electric field measurements with transmediterranean balloons

    Science.gov (United States)

    de La Morena, B. A.; Alberca, L. F.; Curto, J. J.; Holzworth, R. H.

    1993-01-01

    The horizontal component of the stratospheric electric field was measured using a balloon in the ODISEA Campaign of Transmediterranean Balloon Program. The balloon flew between Trapani (Sicily) and El Arenosillo (Huelva, Spain) along the 39 deg N parallel at a height between 34 and 24 km. The high values found for the field on fair-weather and its quasi-turbulent variation, both in amplitude and direction, are difficult to explain with the classical electric field source. A new source, first described by Holzworth (1989), is considered as possibly causing them.

  12. Recent Developments in Balloon Support Instrumentation at TIFR Balloon Facility, Hyderabad.

    Science.gov (United States)

    Vasudevan, Rajagopalan

    2012-07-01

    The Balloon Facility of Tata Institute of Fundamental Research has been conducting stratospheric balloon flights regularly for various experiments in Space Astronomy and Atmospheric Sciences. A continuous improvement in Balloon flight Support instrumentation by the Control Instrumentation Group to keep in space with the growing complexities of the scientific payloads have contributed to the total success of balloon flights conducted recently. Recent improvements in display of Balloon position during balloon flight by showing on real time the balloon GPS position against Google TM maps is of immense help in selecting the right spot for payload landing and safe recovery . For further speeding up the payload recovery process, a new GPS-GSM payload system has been developed which gives SMS of the payload position information to the recovery team on their cell phones. On parallel footing, a new GPS- VHF system has been developed using GPS and Radio Modems for Balloon Tracking and also for obtaining the payload impact point. On the Telecommand side, a single board Telecommand/ Timer weighing less than 2 Kg has been specially developed for use in the mesosphere balloon test flight. The interference on the existing Short Range Telemetry System has been eliminated by introducing a Band Pass Filter and LNA in the Receiving system of the modules, thereby enhancing its reliability. In this paper , we present the details of the above mentioned developments.

  13. Percutaneous transluminal angioplasty (PTA) of supra-aortic arteries especially the internal carotid artery

    Energy Technology Data Exchange (ETDEWEB)

    Kachel, R.; Basche, S. (Medizinische Akademie, Erfurt (Germany, F.R.). Radiologische Klinik); Heerklotz, I.; Grossmann, K. (Medizinische Akademie, Erfurt (Germany, F.R.). Klinik fuer Innere Medizin); Endler, S. (Medizinische Akademie, Erfurt (Germany, F.R.). Klinik fuer Neurologie und Psychiatrie)

    1991-06-01

    We present our experience with 105 patients in whom percutaneous transluminal angioplasty was performed in 112 stenosed or occluded supra-aortic arteries. Symtoms of cerebrovascular and/or vertebrobasilar insufficiency were present in 104 of the 105 patients. The angioplasty was successful in 35 stenoses of the internal carotid artery, 2 stenoses of the common carotid artery, 1 stenosis of the external carotid artery, 15 stenoses of the vertebral artery, 3 stenoses of the innominate artery and 44 stenoses of the subclavian artery. There were only 4 minor-complications (2 haematomas, 1 transient ischemic attack, 1 small thrombus of the internal carotid artery which was detected by 111-indium platelet scintigraphy and treated by thrombendarterectomy before the appearance of neurological symptoms). All patients were symptom free after angioplasty. During the observations period of 3 to 109 months (average 58 months) there were only two cases with re-stenosis after subclavian angioplasty. The results of more than 700 personal and international published percutaneous transluminal angioplasties of supra-aortic arteries are presented. The results suggest that angioplasty of supra-aortic arteries is an effective method. On strict definition of the indications, the complication rate for angioplasty of the supra-aortic arteries is not likely to be higher than that for operative treatment. (orig.).

  14. Shielded Mars Balloon Launcher (SMBL) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Aurora Flight Sciences, along with its partner Vertigo Industries, proposes a novel approach to deployment of balloon-based payloads into the Martian atmosphere....

  15. Magnetometer for Balloons and UAVs Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I SBIR project will investigate a new, low-cost approach to atomic magnetometry that is suited for operation from UAVs and research balloons. Atomic...

  16. Deployment Instabilities of Lobed-Pumpkin Balloon

    Science.gov (United States)

    Nakashino, Kyoichi

    A lobed-pumpkin balloon, currently being developed in ISAS/JAXA as well as in NASA, is a promising vehicle for long duration scientific observations in the stratosphere. Recent ground and flight experiments, however, have revealed that the balloon has deployment instabilities under certain conditions. In order to overcome the instability problems, a next generation SPB called 'tawara' type balloon has been proposed, in which an additional cylindrical part is appended to the standard lobed-pumpkin balloon. The present study investigates the deployment stability of tawara type SPB in comparison to that of standard lobed-pumpkin SPB through eigenvalue analysis on the basis of finite element methods. Our numerical results show that tawara type SPB enjoys excellent deployment performance over the standard lobed-pumpkin SPBs.

  17. Attitude determination for balloon-borne experiments

    CERN Document Server

    Gandilo, N N; Amiri, M; Angile, F E; Benton, S J; Bock, J J; Bond, J R; Bryan, S A; Chiang, H C; Contaldi, C R; Crill, B P; Devlin, M J; Dober, B; Dore, O P; Farhang, M; Filippini, J P; Fissel, L M; Fraisse, A A; Fukui, Y; Galitzki, N; Gambrel, A E; Golwala, S; Gudmundsson, J E; Halpern, M; Hasselfield, M; Hilton, G C; Holmes, W A; Hristov, V V; Irwin, K D; Jones, W C; Kermish, Z D; Klein, J; Korotkov, A L; Kuo, C L; MacTavish, C J; Mason, P V; Matthews, T G; Megerian, K G; Moncelsi, L; Morford, T A; Mroczkowski, T K; Nagy, J M; Netterfield, C B; Novak, G; Nutter, D; O'Brient, R; Pascale, E; Poidevin, F; Rahlin, A S; Reintsema, C D; Ruhl, J E; Runyan, M C; Savini, G; Scott, D; Shariff, J A; Soler, J D; Thomas, N E; Trangsrud, A; Truch, M D; Tucker, C E; Tucker, G S; Tucker, R S; Turner, A D; Ward-Thompson, D; Weber, A C; Wiebe, D V; Young, E Y

    2014-01-01

    An attitude determination system for balloon-borne experiments is presented. The system provides pointing information in azimuth and elevation for instruments flying on stratospheric balloons over Antarctica. In-flight attitude is given by the real-time combination of readings from star cameras, a magnetometer, sun sensors, GPS, gyroscopes, tilt sensors and an elevation encoder. Post-flight attitude reconstruction is determined from star camera solutions, interpolated by the gyroscopes using an extended Kalman Filter. The multi-sensor system was employed by the Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry (BLASTPol), an experiment that measures polarized thermal emission from interstellar dust clouds. A similar system was designed for the upcoming flight of SPIDER, a Cosmic Microwave Background polarization experiment. The pointing requirements for these experiments are discussed, as well as the challenges in designing attitude reconstruction systems for high altitude balloon flights. ...

  18. Retrieving Balloon Data in Flight Project

    Data.gov (United States)

    National Aeronautics and Space Administration —   NASA has plans to fly stratospheric ULDBs for missions of 100 days or more in the next few years. As these balloons circumnavigate the globe multiple...

  19. Exploring expectations and needs of patients undergoing angioplasty.

    Science.gov (United States)

    Aazami, Sanaz; Jaafarpour, Molouk; Mozafari, Mosayeb

    2016-09-01

    This study aimed to explore needs and expectations of Iranian patients who undergone angioplasty procedures. Coronary artery disease is the leading cause of morbidity and mortality worldwide. Recently, Percutaneous Coronary Intervention (PCI) has frequently been used as a substitute for coronary artery surgery, representing a less invasive and more cost-effective procedure. However, little information is known about the experiences and needs of patients undergone PCI. This research involved a qualitative study that employed the content analysis method. A semi-structured in-depth interview protocol was carried out using a face-to-face approach. Researchers reached to theoretical saturation by interviewing 18 patients who undergone angioplasty. Constant comparison analysis was used with simultaneous data collection. Three themes emerged from this study including Uncertainty, Procedural knowledge and Social Support. The findings from this study enhance our understanding on expectations and needs of patients who undergone PCI. These findings help nurses and health-care providers to develop and provide pre and post-procedural care according to each individual needs and experiences. This Iranian study not only contributes to other international study but also, emphasizes on the need for pre-procedural awareness and post-procedural support of patients who undergone PCI. PMID:27568316

  20. Intracoronary radiation therapy using Re-188 after percutaneous coronary angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Chae, In Ho; Lee, Myoung Mook; Lee, Dong Soo [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    1999-07-01

    Percutaneous coronary angioplasty is well established therapeutic modality in the management of coronary artery disease. However, the high restenosis rate of 30 to 50% limits its usefulness. The principal mechanism of restenosis, intimal hyperplasia, is the proliferative response of vessel wall to injury, which consists largely of smooth muscle cells. A large body of animal investigations and a limited number of clinical studies have established the ability of ionizing radiation to reduce neointimal proliferation and restenosis rate significantly. Human studies have been reported that intravascular radiation after first restenosis inhibits a second restenosis. Encouraged by these reports, we are also conducting a double blind, placebo-controlled, randomized trial to evaluate this new therapeutic modality in patients with coronary artery stenosis. The objective of our trial is to determine the safety and efficacy of catheter-based solutional beta emitting radioisotope system in preventing restenosis after angioplasty. This review describes the vascular brachytherapy systems and isotopes that have been utilized in the initial clinical trials performed in this area of past PTCA coronary restenosis. The results of many worldwide ongoing clinical trials will determine whether this new technology will change the future practice of vascular intervention.

  1. Power Systems Design for Long Duration Ballooning

    Science.gov (United States)

    Stilwell, Bryan; Chuzel, Alain

    2016-01-01

    The Columbia Scientific Balloon Facility has been designing and building high-altitude balloon power systems for over 26 years. With that experience, we have found certain types of PV panels, batteries, and charge controllers that are reliable in stratospheric environments. The ultimate goal is to ensure that power systems will provide power reliably throughout the duration of an LDB flight. The purpose of this presentation is to provide some general guidelines and best practices for power system design.

  2. Test ventilation with smoke, bubbles, and balloons

    Energy Technology Data Exchange (ETDEWEB)

    Pickering, P.L.; Cucchiara, A.L.; McAtee, J.L.; Gonzales, M.

    1987-01-01

    The behavior of smoke, bubbles, and helium-filled balloons was videotaped to demonstrate the mixing of air in the plutonium chemistry laboratories, a plutonium facility. The air-distribution patterns, as indicated by each method, were compared. Helium-filled balloons proved more useful than bubbles or smoke in the visualization of airflow patterns. The replay of various segments of the videotape proved useful in evaluating the different techniques and in identifying airflow trends responsible for air mixing. 6 refs.

  3. New stent delivery balloon: a technical note.

    Science.gov (United States)

    di Mario, C; Reimers, B; Reinhardt, R; Ferraro, M; Moussa, I; Colombo, A

    1997-12-01

    This study reports the first clinical application of a new noncompliant balloon composed of a middle polyurethane layer sandwiched between an inner layer of polyethylene terephtalate and an outer membrane that provides for consistent even expansion. With this balloon design, the very low compliance and high pressure resistance of polyethylene terephthalate are associated with the high elasticity of polyurethane, preventing balloon damage from stent crimping and expansion and allowing a firm embedding of the stent struts. Palmaz-Schatz stent implantation was successful in 33/35 stents (94%), and the two stents that could not be advanced up to the lesion were successfully withdrawn. High pressure expansion of the stent was obtained during deployment with no balloon ruptures at inflation pressures equal or lower than 16 atmospheres (atm). Accurate positioning of the stent was facilitated by the two markers at the balloon ends and by the optimal visualization after contrast injection, even with 6 Fr guiding catheters. This new delivery system maintains the advantages of hand-crimped stents on noncompliant balloons, reducing the risk of stent loss. PMID:9408637

  4. Effects of granulocyte-macrophage colony stimulating factor on the repair of vessel intima damaged by balloon

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xing-hua; MA Xiao-jing; ZHAO Tong

    2005-01-01

    Background The dysfunction of vascular endothelial cells plays a key role in starting and facilitating restenosis. The acceleration of intima repair and the recovery of endothelial function would reduce the restenosis rate. This study was undertaken to assess the effect of granulocyte-macrophage colony stimulating factor (GM-CSF) on the repair of damaged iliac arteries.Methods Twenty-four male New Zealand white rabbits undergoing primary iliac artery deendothelialization were randomly divided into two groups (GM-CSF group and control group). The GM-CSF group received a subcutaneous injection of GM-CSF (10 μg·kg-1·d-1), and the control group was given a subcutaneous injection of equivalent saline. The iliac arteries of all animals were damaged by balloon after 7 days. The levels of nitric oxide (NO) were detected before, 1 week, 2 weeks and 4 weeks after angioplasty. The repair and hyperplasia of the intima were observed microscopically and the indices of stenosis were evaluated by computerized planimetry after 4 weeks of angioplasty.Results The NO levels of the GM-CSF group were higher than those of the control group 2 weeks and 4 weeks after angioplasty [(91.92±11.57) μmol/L vs. (81.67±12.18) μmol/L; (97.67±10.13) μmol/L vs. (83.16±12.64) μmol/L]. Four weeks after balloon damage, histological examination showed that neointima formation, vascular smooth muscle cells and fibrous tissue of the GM-CSF group were less than those of the control group. The endothelium of the GM-CSF group was more integrated, and stenosis of lumen was slighter than that of the control group. Morphometry showed the lumen area of the GM-CSF group was larger than that of the control group [(1.27±0.31) mm2 vs. (0.92±0.24) mm2], the neointimal area and percent of intima hyperplasia were significantly smaller than those of the control group [(0.85±0.34) mm2 vs. (1.18±0.38) mm2; (40±7)% vs. (55±6)%].Conclusion GM-CSF could facilitate the repair of the intima, reduce neointima

  5. Is echocardiography or magnetic resonance imaging superior for precoarctation angioplasty evaluation?

    Science.gov (United States)

    Mendelsohn, A M; Banerjee, A; Donnelly, L F; Schwartz, D C

    1997-09-01

    We compared the dimensions of the aorta obtained by two-dimensional transthoracic echocardiography (echo) (median, 2.5 mo preangioplasty) and magnetic resonance imaging (MRI) (median, 4.2 mo preangioplasty) to those obtained by angiography (cath) in 13 patients (age, 7.7 +/- 1.6 yr; mean +/- SEM) who underwent evaluation for coarctation balloon angioplasty between April 1993-January 1996. Echo measurements were obtained from the suprasternal and subcostal sagittal planes, MRI measurements from axial and sagittal oblique views, and cath measurements from the straight lateral or oblique views. Measurements of the diameters of the aortic isthmus, coarctation, descending aorta at the diaphragm, and isthmus length were made by all three modalities. Presence of aorto-aortic collaterals was determined, and the coarctation length was delineated. Investigators were blinded to other measurement data prior to statistical analysis. Data analysis by repeated analysis of variance (ANOVA) and Student-Newman-Keuls testing revealed no statistically significant difference between systolic pressure gradient by clinical examination (32.2 +/- 5.9 mm Hg), peak instantaneous Doppler evaluation (37.5 +/- 2.9 mm Hg), or preangioplasty systolic pressure gradient (32.1 +/- 3.3 mm Hg). With the exception of measurements of the descending aorta (echo, 11.7 +/- 0.9 mm vs. MRI, 13.3 +/- 0.8 mm vs. cath, 14.0 +/- 1.3 mm; P = 0.04), there was no statistically significant difference in dimensions of the aortic isthmus (9.2 +/- 0.6 mm vs. 10.5 +/- 0.9 mm vs. 10.8 +/- 0.9 mm), coarctation site diameter (4.8 +/- 0.6 mm vs. 5.6 +/- 0.9 mm vs. 5.3 +/- 0.8 mm), or isthmus length (12.4 +/- 2.1 mm vs. 12.1 +/- 2.2 mm vs. 10.9 +/- 1.7 mm). The correlation coefficients derived from comparisons of MRI vs. cath to echo vs. cath were similar for all dimensions except for isthmus length (P cardiac function and intracardiac anomalies. Both modalities detected the single patient with a long segment coarctation. We

  6. The French Balloon Program 2013 - 2017

    Science.gov (United States)

    Dubourg, Vincent; Vargas, André; Raizonville, Philippe

    2016-07-01

    With over 50 years' experience in the field, the French Centre National d'Etudes Spatiales (CNES) goes on supporting - as designer and operator - a significant scientific ballooning program. In particular so because balloons still give a unique and valuable access to near space science. From 2008 to 2013, an important renovation effort was achieved, beginning by Zero Pressure Balloons (ZPB) systems, to comply with more stringent Safety constraints and to the growing reliability and performance requirements from scientific missions. The paper will give an overview of the CNES new capabilities and services for operational balloon activities, and their availability status. The scientific launch campaigns of the past two years will be presented. A focus will be made on the results of the Stratoscience 2015 flight campaign from Timmins, Ontario, using the NOSYCA command and control system for ZPB, qualified in flight in 2013. In particular, the PILOT telescope successfully flew during the 2015 campaign, key figures about the flight and mission will be given. An outlook of the new stratospheric long duration flight systems currently in process of developement at CNES will be given, as well as the presentation of the Stratéole 2 project, dedicated to the survey of the low stratosphere and upper troposphere in equatorial regions, with a fleet of small suprer pressure balloons (SPB). As far as tropospheric balloons are concerned, the Aeroclipper initiative will be presented, aiming at qualifying a quasi-tethered balloon, pushed by the winds close to the sea surface, for the study of cyclones. The scientific launch campaigns and the main payloads in the study for the near future will also be presented.

  7. Percutaneous transluminal angioplasty of iliac and femoral arteries in severe lower-limb ischaemia

    DEFF Research Database (Denmark)

    Jørgensen, B; Henriksen, L O; Karle, A;

    1988-01-01

    Percutaneous transluminal angioplasty was performed 92 times in 86 patients with severe lower-limb ischaemia (40% occlusion), giving rise to rest pain and/or gangrene. The patients were thereafter observed for periods up to 5 years. Criteria for success were appearance of normal groin pulse (iliac...... angioplasty) or persistent greater than or equal to 0.15 rise in arm/ankle blood pressure index (femoropopliteal angioplasty). The respective technical success rates were 82% and 64%. The complication rate was 10.9%, including 5.4% distal embolization. Patency rates were higher in iliac than...... in femoropopliteal lesions, in stenotic than occluded vessels, and also when the lesion was shorter than 5 cm and if there was good run-off. Limb salvage exceeded patency by 10% in the iliac procedures and by 15% in the femoropopliteal. Percutaneous transluminal angioplasty is recommended for selected cases...

  8. Simple risk stratification at admission to identify patients with reduced mortality from primary angioplasty

    DEFF Research Database (Denmark)

    Thune, Jens Jakob; Hoefsten, Dan Eik; Lindholm, Matias Greve;

    2005-01-01

    BACKGROUND: Randomized trials comparing fibrinolysis with primary angioplasty for acute ST-elevation myocardial infarction have demonstrated a beneficial effect of primary angioplasty on the combined end point of death, reinfarction, and disabling stroke but not on all-cause death. Identifying......-risk group might have a reduced mortality with an invasive strategy. METHODS AND RESULTS: We classified 1527 patients from the Danish Multicenter Randomized Study on Fibrinolytic Therapy Versus Acute Coronary Angioplasty in Acute Myocardial Infarction (DANAMI-2) trial with information for all variables...... necessary for calculating the TIMI risk score as low risk (TIMI risk score, 0 to 4) or high risk (TIMI risk score > or =5) and investigated the effect of primary angioplasty versus fibrinolysis on mortality and morbidity in the 2 groups. Follow-up was 3 years. We classified 1134 patients as low risk and 393...

  9. Effects of a behavioural intervention on quality of life and related variables in angioplasty patients

    DEFF Research Database (Denmark)

    Appels, Ad; van Elderen, Therese; Bär, Frits;

    2006-01-01

    The EXhaustion Intervention Trial investigated the effect of a behavioural intervention programme on exhaustion, health-related quality of life (HRQL), depression, anxiety, hostility, and anginal complaints in angioplasty patients who felt exhausted after percutaneous coronary intervention (PCI)....

  10. Abnormally high failure rate for femoral angioplasty in patients with pseudoxanthoma elasticum

    NARCIS (Netherlands)

    Ammi, Myriam; Kranenburg, Guido; Omarjee, Loukman; Martin, Ludovic; Spiering, Wilko; Lefthériotis, Georges

    2015-01-01

    Pseudoxanthoma elasticum (PXE) is an inherited disease characterized by skin lesions, central blindness, and progressive peripheral occlusive disease. Severe claudication is a frequent symptom for which angioplasty represents a possible therapeutic avenue. We report the outcomes of four patients wit

  11. Angioplasty of symptomatic high-grade internal carotid artery stenosis with intraluminal thrombus: therapeutic approach

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, A.; Mayol, A. [Seccion de Neurorradiologia Intervencionista, Servicio de Radiologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Gil-Peralta, A.; Gonzalez-Marcos, J.R. [Servicio de Neurologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Boza, F. [Servicio de Neurofisiologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Ruano, J. [Unidad de Cuidados Intensivos, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain)

    2004-04-01

    Intraluminal thrombus in the internal carotid artery (ICA) is usually found in patients with severe atheromatous stenosis. Having reviewed 300 carotid angioplasties for symptomatic >70% ICA stenosis, we found three patients (1%) with intraluminal thrombus. Conservative treatment with anticoagulants and double antiplatelet coverage can result in lysis of the thrombus without severe risks. Percutaneous transluminal angioplasty and stenting, preferably with distal protection, can be an excellent alternative to carotid endarterectomy. (orig.)

  12. ON THE SAFETY OF CONTRAST MEDIA USAGE DURING CORONARY ANGIOPLASTY IN KIDNEY TRANSPLANT RECIPIENTS

    Directory of Open Access Journals (Sweden)

    I. G. Ryadovoy

    2010-01-01

    Full Text Available In the present study influence of contrast media on renal transplant function in patients with ischemic heart disease treated by coronary angioplasty and stenting waz estimated. Results are based on clinical and angiographic data, the analysis of amount of contrast media, average speed of it introduction, level of creatinine before and at the first 48 hours after coronary angioplasty in 42 patients with renal transplant. 

  13. Combination of Rotational Atherothrombectomy and Paclitaxel-Coated Angioplasty for Femoropopliteal Occlusion

    OpenAIRE

    Scheer, F; CW Lüdtke; P Kamusella; Wiggermann, P; Vieweg, H; Schlöricke, E; Lichtenberg, M.; R Andresen; Wissgott, C

    2015-01-01

    OBJECTIVE The rotational atherothrombectomy with Straub Rotarex® is a safe and efficient treatment of acute/subactute vascular occlusions. The purpose of this study was to evaluate the benefit of paclitaxel-coated angioplasty after rotational atherothrombectomy over an observation period of six months. MATERIALS AND METHODS Overall, 29 patients were treated with the Rotarex catheter in combination with paclitaxel-coated angioplasty. All patients had acute/subacute and chronic occlusions of th...

  14. Comparative efficacy of eptifibatide and abciximab in primary angioplasty study

    Directory of Open Access Journals (Sweden)

    Rohan Jayasinghe

    2011-02-01

    Full Text Available Rohan Jayasinghe1 Matias Yudi1 Sanjay Jayasinghe21Cardiology Department, Gold Coast Hospital, Griffith University, Queensland, Australia; 2Centre for Immunisation Research, Sydney, AustraliaBackground: Primary percutaneous intervention is the safest and most effective treatment modality for acute ST-segment elevation myocardial infarction (MI in centers where catheterization facilities exist. Intravenous glycoprotein IIb/IIIa inhibitor therapy during the procedures has been proven to provide added benefits. For the two agents, abciximab and eptifibatide, commonly used in this context, there is only limited comparative data available for the clinicians. Hitherto, there is no data published from the Asia–Pacific region on this topic.Method: A retrospective comprehensive analysis was carried out, comparing patients who were treated with abciximab (n = 125 and eptifibatide (n = 125 during primary angioplasty over a 3-year period. The primary outcome measure was in-hospital mortality. The other outcome measures studied include MI, stroke, blood transfusion, contrast nephropathy, significant bleeding, and vascular complications. A comparative cost analysis was carried out to ascertain the average overall differential cost.Results: In-hospital mortality, MI, stroke, blood transfusion, contrast nephropathy, significant bleeding, and vascular complication were observed at a higher rate in the patients who were treated with abciximab. However, these differences did not reach statistical significance. Due to the higher cost per unit and longer hospital stay, therapy with abciximab costs more than that with eptifibatide.Conclusions: Both abciximab and eptifibatide are safe and effective adjunct therapeutic agents in the setting of primary angioplasty. However, there is a trend toward higher adverse event with the former agent that was not statistically significant. Therapy with abciximab costs more per patient.Keywords: abciximab, eptifibatide, PCI, STEMI

  15. Ballooning mode instability at the plasmapause

    Science.gov (United States)

    Lakhina, G. S.; Mond, M.; Hameiri, E.

    1990-01-01

    The ballooning mode instability, which can excite hydromagnetic waves at the plasmapause, is studied in the presence of azimuthal plasma flows induced during geomagnetically disturbed periods. A general sufficient criterion for the ballooning mode stability is derived, for a change in the potential energy greater than or equal to 0, which involves the integration over an entire field line. A local stability analysis at the equatorial plasmapause region shows that the ballooning modes could be spontaneously generated via instability under at least two conditions: one is similar to the usual interchange condition, and the second to the quasi-interchange modes. Both of these local instability conditions can be derived from the general stability criterion. Finally an exact solution for the equilibrium state with flow is derived analytically, and the change in the potential energy is computed numerically. It is found that, in the cases studied, the flow does not spontaneously excite the ballooning modes; it only further stabilizes (or destabilizes) the ballooning spectrum if originally the system is stable (or unstable). The analysis would be useful for the interpretation of some of the low-frequency modes observed at the ground and near the equatorial plasmapause.

  16. Femoro-popliteal artery occlusions treated by percutaneous transluminal angioplasty and enclosed thrombolysis

    DEFF Research Database (Denmark)

    Tønnesen, K H; Holstein, P; Andersen, E

    1991-01-01

    Removal of fibrin from the site of a newly dilated femoro-popliteal occlusion may be an attractive way of preventing rethrombosis. A double balloon catheter with a dilating tip balloon and an occlusive balloon 10, 15 or 20 cm approximately were introduced percutaneously. Following successful dila...

  17. Near ultraviolet spectrograph for balloon platform

    Science.gov (United States)

    Sreejith, A. G.; Safonova, Margarita; Murthy, Jayant

    2015-06-01

    Small and compact scientific payloads may be easily designed constructed and own on high altitude balloons. Despite the fact that large orbital observatories provide accurate observations and statistical studies of remote and/or faint space sources, small telescopes on board balloons or rockets are still attractive because of their low cost and rapid response time. We describe here a near ultraviolet (NUV) spectrograph designed to be own on a high{altitude balloon platform. Our basic optical design is a modified Czerny-Turner system using off the shelf optics. We compare different methods of aberration corrections in such a system. We intend the system to be portable and scalable to different telescopes. The use of reflecting optics reduces the transmission loss in UV. We plan on using an image intensified CMOS sensor operating in photon counting mode as the detector of choice.

  18. There is a Text in 'The Balloon'

    DEFF Research Database (Denmark)

    Elias, Camelia

    2009-01-01

    From the Introduction: Camelia Elias' "There is a Text in 'The Balloon': Donald Barthelme's Allegorical Flights" provides its reader with a much-need and useful distinction between fantasy and the fantastic: "whereas fantasy in critical discourse can be aligned with allegory, in which a supernatu......From the Introduction: Camelia Elias' "There is a Text in 'The Balloon': Donald Barthelme's Allegorical Flights" provides its reader with a much-need and useful distinction between fantasy and the fantastic: "whereas fantasy in critical discourse can be aligned with allegory, in which...... York in Donald Barthelme's short story  "The Balloon" from 1968 is discussed in the light of the chapter's epistemological understanding of fantasy....

  19. High altitude balloon experiments at IIA

    Science.gov (United States)

    Nayak, Akshata; Sreejith, A. G.; Safonova, Margarita; Murthy, Jayant

    Recent advances in balloon experiments as well as in electronics have made it possible to fly scientific payloads at costs accessible to university departments. We have begun a program of high altitude ballooning at the Indian Institute of Astrophysics, Bengaluru. The primary purpose of this activity is to test low-cost ultraviolet (UV) payloads for eventual space flight, but we will also try scientific exploration of the phenomena occurring in the upper atmosphere, including sprites and meteorite impacts. We present the results of the initial experiments carried out at the CREST campus of IIA, Hosakote, and describe our plans for the future.

  20. Particle Astrophysics in NASA's Long Duration Balloon Program

    CERN Document Server

    Gorham, Peter W

    2013-01-01

    A century after Viktor Hess' discovery of cosmic rays, balloon flights still play a central role in the investigation of cosmic rays over nearly their entire spectrum. We report on the current status of NASA balloon program for particle astrophysics, with particular emphasis on the very successful Antarctic long-duration balloon program, and new developments in the progress toward ultra-long duration balloons.

  1. Particle Astrophysics in NASA's Long Duration Balloon Program

    International Nuclear Information System (INIS)

    A century after Viktor Hess' discovery of cosmic rays, balloon flights still play a central role in the investigation of cosmic rays over nearly their entire spectrum. We report on the current status of NASA balloon program for particle astrophysics, with particular emphasis on the very successful Antarctic long-duration balloon program, and new developments in the progress toward ultra-long duration balloons

  2. Small dense low density lipoprotein particles are associated with poor outcome after angioplasty in peripheral artery disease.

    Directory of Open Access Journals (Sweden)

    Vincenzo Jacomella

    Full Text Available PURPOSE: In patients suffering from symptomatic peripheral artery disease (PAD, percutaneous revascularization is the treatment of choice. However, restenosis may occur in 10 to 60% in the first year depending on a variety of factors. Small dense low density lipoprotein (sdLDL particles are associated with an increased risk for cardiovascular events, but their role in the process of restenosis is not known. We conducted a prospective study to analyze the association of sdLDL particles with the outcome of balloon angioplasty in PAD. The composite primary endpoint was defined as improved walking distance and absence of restenosis. METHODS: Patients with angiographically documented PAD of the lower extremities who were scheduled for lower limb revascularization were consecutively recruited for the study. At baseline and at three month follow-up triglyceride, total cholesterol, LDL size and subclasses and HDL cholesterol and ankle-brachial index (ABI were measured. Three months after the intervention duplex sonography was performed to detect restenosis. RESULTS: Sixty-four patients (53% male with a mean age of 68.6±9.9 years were included. The proportion of small- dense LDL particles (class III and IV was significantly lower (33.1±11.0% vs. 39.4±12.1%, p = 0.038 in patients who reached the primary end-point compared with those who did not. Patients with improved walking distance and without restenosis had a significantly higher LDL size at baseline (26.6±1.1 nm vs. 26.1±1.1 nm, p = 0.046 and at follow-up (26.7±1.1 nm vs. 26.2±0.9 nm, p = 0.044 than patients without improvement. CONCLUSIONS: Small-dense LDL particles are associated with worse early outcome in patients undergoing percutaneous revascularization for symptomatic PAD.

  3. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine...

  4. Auditory Risk of Exploding Hydrogen-Oxygen Balloons

    Science.gov (United States)

    Gee, Kent L.; Vernon, Julia A.; Macedone, Jeffrey H.

    2010-01-01

    Although hydrogen-oxygen balloon explosions are popular demonstrations, the acoustic impulse created poses a hearing damage risk if the peak level exceeds 140 dB at the listener's ear. The results of acoustical measurements of hydrogen-oxygen balloons of varying volume and oxygen content are described. It is shown that hydrogen balloons may be…

  5. Increased Production of Sonic Hedgehog by Ballooned Hepatocytes

    OpenAIRE

    Rangwala, Fatima; Cynthia D Guy; Lu, Jiuyi; SUZUKI, Ayako; Burchette, James L.; Abdelmalek, Manal F; Chen, Wei; Diehl, Anna Mae

    2011-01-01

    Ballooned hepatocytes distinguish nonalcoholic steatohepatitis (NASH) from steatosis. Such cells contain dilated endoplasmic reticulum and ubiquitin aggregates, characteristics of endoplasmic reticulum stress. Hepatocyte ballooning increases risk for fibrosis in NASH, suggesting ballooned hepatocytes release pro-fibrogenic factors. Hedgehog ligands function as pro-fibrogenic factors in liver diseases, but mechanisms for Hedgehog ligand production remain poorly understood. We evaluated the hyp...

  6. Plasma levels following application of paclitaxel-coated balloon catheters in patients with stenotic or occluded femoropopliteal arteries

    Energy Technology Data Exchange (ETDEWEB)

    Freyhardt, Patrick; Kroencke, T.J.; Schreiter, N.F.; Sixt, S.; Rastan, A. [Charite Universitaetsmedizin, Berlin (Germany). Klinik fuer Strahlenheilkunde; Zeller, T.; Schwarzwaelder, U. [Herzzentrum Bad Krozingen (Germany). Abt. fuer Klinische und Interventionelle Angiologie; Stiepani, H.; Werk, M. [Martin-Luther-Krankenhaus, Berlin (Germany). Klinik fuer Radiologie und Nuklearmedizin

    2011-05-15

    Purpose: Paclitaxel-coated balloon catheters inhibit restenosis after coronary and peripheral angioplasty (PCI,PTA). The aim of this study was to investigate paclitaxel plasma levels and laboratory parameters following PTA with paclitaxel-coated balloons (PCB) in peripheral arteries. Materials and Methods: This single treatment arm, multicenter study included 14 patients with Rutherford stage 1 - 5 with occlusions of up to 5 cm or {>=} 70 % diameter stenosis of the superficial femoral or popliteal arteries (SFA, PA). PTA was performed using up to three PCB catheters. The paclitaxel plasma levels and safety laboratory parameters were determined by collecting blood samples pre-intervention, immediately post-intervention, at 0.5, 1, 2, 4, 8, 24 hours and 1 and 4 weeks post-intervention (p. i.). Vital signs were monitored to assess clinical safety. Results: PTA was performed successfully in all patients. Paclitaxel plasma levels were always below a level and duration known to cause systemic side effects. A mean peak paclitaxel plasma level (40 ng/ml) was reached immediately p. i. and decreased rapidly below detectable levels in more than half of the patients already 2 hours p. i. The paclitaxel plasma concentrations returned to values below detectable levels at 24 hours p. i. in all patients. Laboratory parameters and vital signs did not give any reason for safety concerns. No adverse events associated with balloon coating were observed. Conclusion: The results of 14 patients with peripheral arterial occlusive disease show no systemic bioavailability of paclitaxel > 24 hours after PTA with one or more PCB catheters, indicating that the PCB catheter is safe with regard to possible systemic effects. (orig.)

  7. Acetylbritannilactone Inhibits Neointimal Hyperplasia after Balloon Injury of Rat Artery by Suppressing Nuclear Factor-{kappa}B Activation.

    Science.gov (United States)

    Liu, Bin; Han, Mei; Wen, Jin-Kun

    2008-01-01

    Based on our previous observations that 1-O-acetylbritannilactone (R)-4((3aS,4S,7aR)-4-hydroxy-6-methyl-3-methylene-2-oxo-2,3,3a,4,7,7a-hexahydrobenzofuran-5-yl)pentyl acetate (ABL) suppresses prostaglandin E(2) and nitric oxide synthesis in macrophages, the present study was designed to explore the effect of ABL on neointimal hyperplasia after balloon injury and its mechanism of action. In male Sprague-Dawley rats, 26 mg/kg ABL or polyglycol (control) was administered daily from 3 days before injury to 2 weeks after conventional balloon injury. ABL administration led to a significant reduction in neointimal formation (neointima to media ratio, 1.94 +/- 0.43 versus 0.84 +/- 0.29, P < 0.01) and proliferative activity of vascular smooth muscle cells after balloon injury in rats. Western blot analysis revealed that this is correlated to the inhibition of nuclear factor (NF)-kappaB activation and to the reduced expression of cyclooxygenase-2. Investigation of potential signaling pathways demonstrated that ABL inhibited NF-kappaB activation via the blockade of the inhibitor of NF-kappaB kinase-beta activation and the suppression of the degradation of the inhibitors of NF-kappaB-alpha. These findings suggest that ABL is a potential inhibitor of neointimal formation because it blocks injury-induced NF-kappaB activation and may have beneficial effects in reducing the risk of restenosis after angioplasty. PMID:17911374

  8. Application of bidirectional subintimal angioplasty in atherosclerotic occlusion of lower extremities%双向内膜下血管成形术在治疗下肢动脉闭塞症中的应用

    Institute of Scientific and Technical Information of China (English)

    路军良; 李京雨; 张强; 徐力扬; 刘涛

    2009-01-01

    Objective To discuss the therapeutic efficacy of bidirectional subintimal angioplasty in the treatment of atherosclerotic occlusive of lower limbs. Methods Five patients with long segment of obstructed artery in lower limb were enrolled in the study. Of five patients, occlusion of the lower segment of abdominal aorta and bilateral iliac artery was seen in one, occlusion of iliac artery in 2 and occlusion of superficial femoral artery in the remaining two. Antegrade subintimal angioplasty procedure was unsuccessful in all five patients as the wire could not be placed into the true lumen, so retrograde subintimal angioplasty by puncturing the distal segment of the occlusive artery was employed. Through the newly created channel the retrograde guide wire was manipulated to be pulled out of vessel through the antegrade catheter. The subintimal tract was dilated with angioplasty balloon and the stent implantation was performed. Results Bidirectional subintimal angioplasty was successfully accomplished in all five patients, with a total of nine stents being implanted. Conclusion Bidirectional subintimal angioplasty is a safe and effective procedure for bringing the subintimal recanalization to success, this technique can be regarded as a remedial measure when unidirectional subintimal angioplasty ends up in failure.%目的 探讨双向内膜下血管成形术在治疗周围动脉完全闭塞性病变中的意义.方法 采用双向内膜下血管成形术治疗5例长段动脉闭塞患者,其中腹主动脉下端合并两侧髂总动脉及髂外动脉闭塞1例,髂外动脉闭塞2例,股浅动脉闭塞2例.在单向内膜下再通时,进人真腔失败后而在患肢闭塞动脉远端血管穿刺,使用导丝从病变对侧进入闭塞段内膜下,在病变内膜下腔,采用导丝贯穿至对侧导管技术,成功后,将导丝从对侧导管引出体外,然后用球囊扩张成型并植入支架.结果 本组5例患者均成功完成双向

  9. Single-balloon versus double-balloon bipedicular kyphoplasty for osteoporotic vertebral compression fractures.

    Science.gov (United States)

    Wang, Heng; Sun, Zhenzhong; Wang, Zhiwen; Jiang, Weimin

    2015-04-01

    Twenty-eight patients with osteoporotic vertebral compression fractures (OVCF) were treated with single-balloon bipedicular kyphoplasty (Group A), and 40 patients were treated with double-balloon bipedicular kyphoplasty (Group B). Visual Analogue Scale (VAS) score, vertebral height, and kyphotic angle (KA) were evaluated pre-operatively, post-operatively (3 days after surgery) and at final follow-up. Operative time, X-ray exposure frequency and costs were recorded. The mean operative time and X-ray exposure frequency in Group A were greater than in Group B (pkyphoplasty is a safe and cost-effective surgical method for the treatment of OVCF. It can achieve pain relief comparable with double-balloon bipedicular kyphoplasty. However, double-balloon bipedicular kyphoplasty is more efficacious in terms of the restoration of vertebral height and reduction of KA, and the operative time and X-ray exposure frequency are lower.

  10. Survey of balloon design problems and prospects for large super-pressure balloons in the next century

    Science.gov (United States)

    Yajima, Nobuyuki

    About a half century has passed since modern scientific ballooning started in the 1950's. All this while, size and payload capabilities of zero-pressure balloons have improved rapidly. On the other hand, a super-pressure balloon which can take the place of a conventional large zero-pressure balloon has not yet become operational. To investigate this problem, previous research on balloon design is surveyed. It is concluded that quite important design problems have been left unsolved. Problems occur when a load tape assembly is introduced to the natural shape balloon system. The author proposed a new balloon design concept, named 3-D gore design, at the last COSPAR held in Nagoya in 1998. This theory improves the conventional natural shape design concept for the balloon reinforced by load tapes. This new design concept enables enhancing the strength of a balloon dramatically. In addition, the strength does not depend on balloon size. This theory will accelerate the development of large super-pressure balloons which will play a leading role in scientific ballooning in the 21st century.

  11. Attitude determination for balloon-borne experiments

    Science.gov (United States)

    Gandilo, N. N.; Ade, P. A. R.; Amiri, M.; Angilè, F. E.; Benton, S. J.; Bock, J. J.; Bond, J. R.; Bryan, S. A.; Chiang, H. C.; Contaldi, C. R.; Crill, B. P.; Devlin, M. J.; Dober, B.; Doré, O. P.; Farhang, M.; Filippini, J. P.; Fissel, L. M.; Fraisse, A. A.; Fukui, Y.; Galitzki, N.; Gambrel, A. E.; Golwala, S.; Gudmundsson, J. E.; Halpern, M.; Hasselfield, M.; Hilton, G. C.; Holmes, W. A.; Hristov, V. V.; Irwin, K. D.; Jones, W. C.; Kermish, Z. D.; Klein, J.; Korotkov, A. L.; Kuo, C. L.; MacTavish, C. J.; Mason, P. V.; Matthews, T. G.; Megerian, K. G.; Moncelsi, L.; Morford, T. A.; Mroczkowski, T. K.; Nagy, J. M.; Netterfield, C. B.; Novak, G.; Nutter, D.; O'Brient, R.; Pascale, E.; Poidevin, F.; Rahlin, A. S.; Reintsema, C. D.; Ruhl, J. E.; Runyan, M. C.; Savini, G.; Scott, D.; Shariff, J. A.; Soler, J. D.; Thomas, N. E.; Trangsrud, A.; Truch, M. D.; Tucker, C. E.; Tucker, G. S.; Tucker, R. S.; Turner, A. D.; Ward-Thompson, D.; Weber, A. C.; Wiebe, D. V.; Young, E. Y.

    2014-07-01

    An attitude determination system for balloon-borne experiments is presented. The system provides pointing information in azimuth and elevation for instruments flying on stratospheric balloons over Antarctica. In-flight attitude is given by the real-time combination of readings from star cameras, a magnetometer, sun sensors, GPS, gyroscopes, tilt sensors and an elevation encoder. Post-flight attitude reconstruction is determined from star camera solutions, interpolated by the gyroscopes using an extended Kalman Filter. The multi-sensor system was employed by the Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry (BLASTPol), an experiment that measures polarized thermal emission from interstellar dust clouds. A similar system was designed for the upcoming flight of Spider, a Cosmic Microwave Background polarization experiment. The pointing requirements for these experiments are discussed, as well as the challenges in designing attitude reconstruction systems for high altitude balloon flights. In the 2010 and 2012 BLASTPol flights from McMurdo Station, Antarctica, the system demonstrated an accuracy of < 5' rms in-flight, and < 5" rms post-flight.

  12. Treatment of tuberculous bronchostenosis: balloon bronchoplasty

    International Nuclear Information System (INIS)

    The purpose of this study is to evaluate the efficacy of the balloon bronchoplasty in the treatment of the tuberculous bronchostenosis. Balloon bronchoplasty was performed in thirteen patients with stenosis of the left main bronchus (two with combined left upper and lower lobar bronchostenosis) using a inflatable balloon catheter under a fluoroscopic guide. We analysed the changes in the severity of dyspnea and wheezing, serial FEV1/FVC as a parameter of the airflow obstruction, and bronchial diameter and lung volume on chest radiographs. The extent of pulmonary tuberculosis was correlated with the improvement of FEV1/ FVC. There was an improvement of dyspnea in 69% (9/13), decrease of wheezing in 69% (9/13), significant increase of FEV1/FVC in 18% (2/11). The increase of the bronchial diameter and lung volume were seen in 84% (11/13) and 53% (7/13), respectively. The significant increase of FEV1/FVC was seen in 28% (2/7) of the patients with lung involvement of tuberculous less than one third of left upper lobe, whereas there was no increase in those of more than one third. The was no complication except transient leukocytosis, fever and blood-tinged sputum. In conclusion, balloon bronchoplasty is effective in the treatment of medically intractable tuberculous bronchostenosis, and can be considered as an initial method of treatment

  13. Endovascular treatment with angioplasty or stenting versus endarterectomy in patients with carotid artery stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): long-term follow-up of a randomised trial.

    LENUS (Irish Health Repository)

    Ederle, Jörg

    2009-10-01

    Endovascular treatment (angioplasty with or without stenting) is an alternative to carotid endarterectomy for carotid artery stenosis but there are scarce long-term efficacy data showing that it prevents stroke. We therefore report the long-term results of the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS).

  14. Primary coronary angioplasty in 9,434 patients during acute myocardial infarction: predictors of major in- hospital adverse events from 1996 to 2000 in Brazil

    Directory of Open Access Journals (Sweden)

    Mattos Luiz Alberto

    2002-01-01

    Full Text Available OBJECTIVE: To verify the results after the performance of primary coronary angioplasty in Brazil in the last 4 years. METHODS: During the first 24 hours of acute myocardial infarction onset, 9,434 (12.2% patients underwent primary PTCA. We analyzed the success and occurrence of major in-hospital events, comparing them over the 4-year period. RESULTS: Primary PTCA use increased compared with that of all percutaneous interventions (1996=10.6% vs. 2000=13.1%; p<0.001. Coronary stent implantation increased (1996=20% vs. 2000=71.9%; p<0.001. Success was greater (1998=89.5% vs. 1999=92.5%; p<0.001. Reinfarction decreased (1998=3.9% vs. 99=2.4% vs. 2000=1.5%; p<0.001 as did emergency bypass surgery (1996=0.5% vs. 2000=0.2%; p=0.01. In-hospital deaths remained unchanged (1996=5.7% vs. 2000=5.1%, p=0.53. Balloon PTCA was one of the independent predictors of a higher rate of unsuccessful procedures (odds ratio 12.01 [CI=95%] 1.58-22.94, and stent implantation of lower mortality rates (odds ratio 4.62 [CI=95%] 3.19-6.08. CONCLUSION: The success rate has become progressively higher with a significant reduction in reinfarction and urgent bypass surgery, but in-hospital death remains nearly unchanged. Coronary stenting was a predictor of a lower death rate, and balloon PTCA was associated with greater procedural failure.

  15. Measurements of gondola motion on a stratospheric balloon flight

    CERN Document Server

    Safonova, Margarita; Sreejith, A G; Sarpotdar, Mayuresh; Ambily, S; Prakash, Ajin; Mathew, Joice; Murthy, Jayant; Anand, Devarajan; Kapardhi, B V N; Kumar, B Suneel; Kulkarni, P M

    2016-01-01

    Balloon experiments are an economically feasible method of conducting observations in astronomy that are not possible from the ground. The astronomical payload may include a telescope, a detector, and a pointing/stabilization system. Determining the attitude of the payload is of primary importance in such applications, to accurately point the detector/telescope to the desired direction. This is especially important in generally unstable lightweight balloon flights. However, the conditions at float altitudes, which can be reached by zero pressure balloons, could be more stable, enabling accurate pointings. We have used the Inertial Measurement Unit (IMU), placed on a stratospheric zero pressure balloon, to observe 3-axis motion of a balloon payload over a fight time of 4.5 hours, from launch to the float altitude of 31.2 km. The balloon was launched under nominal atmospheric conditions on May 8th 2016, from a Tata Institute of Fundamental Research Balloon Facility, Hyderabad.

  16. Early outcomes after carotid angioplasty with stenting performed by neurologists

    Directory of Open Access Journals (Sweden)

    Bathala Lokesh

    2010-01-01

    Full Text Available Aims: To evaluate the results of carotid artery angioplasty and stenting (CAS in treating extracranial carotid artery stenosis performed by neurologists in our center and compare the results with other large published series. Materials and Methods: Data for all patients who underwent CAS from January 2003 through November 2007, was retrieved from the Nanjing Stroke Registry. Perioperative and post-procedural complications within 30 days following stenting were analyzed and compared with that from other series. A total number of 75 patients were enrolled, with a mean age of 65.9 ± 8.8 years, and 64 (85.3% of them were male. Results: Procedural success was achieved in 74 patients (98.7%. Pre-treatment stenosis was 73.8 ± 14.9 and post-treatment residual stenosis was less than 10%. Thirty-four patients (45.3% had bilateral carotid artery disease and seven (9.3% had tandem stenosis. The neurological complication rate was 3.9% (one major and two minor strokes. Bradycardia in four (5.3% and hypotension in 13 (17.3% were observed during procedures. Using the Fischer′s exact t test, the complication rate compared with the large published series did not reveal any statistically significant difference (P > 0.05. Conclusions: We conclude that neurologists, with adequate training, can develop and add this technical skill to the existing cognitive skill of vascular neurology and safely perform stenting.

  17. Einfluß unterschiedlicher klinischer und anamnestischer Parameter auf die Erfolgsaussichten der perkutanen transluminalen renalen Angioplastie : eine retrospektive Studie

    OpenAIRE

    Bröhr, Marlon Andreas Paul

    2002-01-01

    Between 1993 and 1998 171 patients had a percutaneous transluminal angioplasty of the renal artery. It was examinated in which way different clinal and anamnestic parameters (sex, age, nicotin-abusus, use of stens, pathogenesis of the stenosis) did influence the long-time results of percutaneous transluminal angioplasty of the renal artery.

  18. Amputation-Free Survival after Crural Percutaneous Transluminal Angioplasty for Critical Limb Ischemia

    DEFF Research Database (Denmark)

    Strøm, M; Konge, L; Lönn, L;

    2016-01-01

    BACKGROUND AND AIM: To evaluate the amputation-free survival after below the knee percutaneous transluminal angioplasty in a consecutive group of patients with critical ischemia of the lower extremity. MATERIALS AND METHODS: A total of 70 consecutive patients with critical ischemia were treated...... with below the knee percutaneous transluminal angioplasty at the vascular center at Rigshospitalet with the purpose of limb salvage. All patients were deemed unfit for major surgery due to anatomical limitations or severe co-morbidity, and no prior attempts of revascularization were performed. Follow...... within the first year. Complications after percutaneous transluminal angioplasty were rare. Cumulative mortality after 1 and 2 years was 22% and 34%, respectively. Amputation-free survival at 1 and 2 years of follow-up was 68% and 58%, respectively. There were no association between known risk factors...

  19. Balloon-borne gamma-ray polarimetry

    CERN Document Server

    Pearce, Mark

    2011-01-01

    The physical processes postulated to explain the high-energy emission mechanisms of compact astrophysical sources often yield polarised soft gamma rays (X-rays). PoGOLite is a balloon-borne polarimeter operating in the 25-80 keV energy band. The polarisation of incident photons is reconstructed using Compton scattering and photoelectric absorption in an array of phoswich detector cells comprising plastic and BGO scintillators, surrounded by a BGO side anticoincidence shield. The polarimeter is aligned to observation targets using a custom attitude control system. The maiden balloon flight is scheduled for summer 2011 from the Esrange Space Centre with the Crab and Cygnus X-1 as the primary observational targets.

  20. Gadopentetate dimeglumine as a contrast agent in peripheral angioplasty. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, J.M.; Smiddy, P.; Molloy, M.P. [St. Jame`s Hospital, Dublin (Ireland). Dept. of Diagnostic Imaging; O`Hare, N.J. [St. Jame`s Hospital, Dublin (Ireland). Dept. of Medical Physics

    1998-09-01

    Gadopentetate dimeglumine (Gd-DTPA) is widely used as a contrast agent in MR imaging. We report on a case in which Gd-DTPA was used as the contrast agent during angioplasty in a patient who had recently had an adverse reaction to a non-ionic iodinated contrast medium. Gd-DTPA allowed a diagnostic angiogram to be performed with no side effects, and may thus be a useful contrast agent at angioplasty in patients with contra-indications to iodinated contrast media. (orig.)

  1. Endovascular angioplasty before resection of a sphenoidal meningioma with vascular encasement.

    Science.gov (United States)

    Chivoret, N; Fontaine, D; Lachaud, S; Chau, Y; Sedat, J

    2011-09-01

    We describe a case of sphenoid wing meningioma presenting with cerebral infarction due to extended vascular encasement in which endovascular angioplasty was performed before surgery to avoid perioperative ischemia. A severe stenosis involved the intracranial internal carotid artery and the proximal segments of the middle and anterior cerebral arteries. Endovascular dilatation was followed by complete surgical resection. Preoperative mild aphasia and hemiparesia resolved completely after surgery. Endovascular angioplasty of arterial trunks and their branches can be proposed before the resection of skull base meningiomas encasing these arteries to decrease the risk of perioperative brain ischemia related to their surgical manipulation or vasospasm.

  2. Pneumothorax, music and balloons: A case series

    OpenAIRE

    2013-01-01

    We describe two cases of spontaneous pneumothorax in young healthy adults with no underlying structural lung disease. The onset of pneumothorax was following physical activity including playing musical instruments and blowing of balloons. There is sparse data evaluating the pathophysiology of primary spontaneous pneumothorax in relation to increased mouth pressures. These cases highlight the possible physical effect of valsalva manoeuvre on transpulmonary pressures, and the potential risk of ...

  3. Coronary artery dissection by an oversized balloon.

    Science.gov (United States)

    Yafi, Wael; Jacquemin, Laurent

    2014-01-01

    Percutaneous coronary intervention (PCI) as a treatment of coronary artery disease can be a simple, rapid procedure with a clear benefit for the patient, but it could also become a complex procedure with fatal consequences. These complications depend on the lesion itself, material used and also on operating staff. In this case we report a coronary artery dissection of the circumflex (CX) artery caused by inflation of an oversized balloon. We discuss here the management and evolution of this complication. PMID:25479753

  4. Double balloon enteroscopy examinations in general anesthesia

    Institute of Scientific and Technical Information of China (English)

    Laszlo; Zubek; Lena; Szabo; Peter; Laszlo; Lakatos; Janos; Papp; Janos; Gal; Gabor; Elo

    2010-01-01

    AIM:To demonstrate that the double balloon enteroscopy(DBE) can be safely performed in general anesthesia with intubation.METHODS:We performed a retrospective examination between August 2005 and November 2008 amongpatients receiving intubation narcosis due to DBE examination.The patients were grouped based on sex,age and physical status.Anesthesia records includedduration of anesthesia,quantity of medication usedand anesthesia-related complications.We determinedthe frequency of complications in the differen...

  5. Numerical Modelling Of Pumpkin Balloon Instability

    Science.gov (United States)

    Wakefield, D.

    Tensys have been involved in the numerical formfinding and load analysis of architectural stressed membrane structures for 15 years. They have recently broadened this range of activities into the `lighter than air' field with significant involvement in aerostat and heavy-lift hybrid airship design. Since early 2004 they have been investigating pumpkin balloon instability on behalf of the NASA ULDB programme. These studies are undertaken using inTENS, an in-house finite element program suite based upon the Dynamic Relaxation solution method and developed especially for the non-linear analysis and patterning of membrane structures. The paper describes the current state of an investigation that started with a numerical simulation of the lobed cylinder problem first studied by Calladine. The influence of material properties and local geometric deformation on stability is demonstrated. A number of models of complete pumpkin balloons have then been established, including a 64-gore balloon with geometry based upon Julian Nott's Endeavour. This latter clefted dramatically upon initial inflation, a phenomenon that has been reproduced in the numerical model. Ongoing investigations include the introduction of membrane contact modelling into inTENS and correlation studies with the series of large-scale ULDB models currently in preparation.

  6. Lightweight Reusable Solar Array For Balloons

    Science.gov (United States)

    Aaron, K.; Tensor, P.; Nock, K.; Wyszkowski, C.

    We will discuss a new lightweight reusable solar array system, dubbed HighPower, which is being developed for the Ultra-Long Duration Balloon (ULDB) program using NASA/SBIR funding, but which is also applicable to other balloon systems. The system uses a vertically deployed stack of panels suspended from their corners by cables. The stack act likes a two-dimensional Venetian blind. By raising and lowering opposite corners, the array of parallel panels can be pointed over most of the upper hemisphere. This allows the panels to remain normal to the sun despite the slow rotation of the gondola and without requiring rotation of the system (no slip rings) or heavy cantilevered rotation joints. The system is sized to generate 2000 W using six 2m x 2m panels. The modularity of the system allows panels to be added or removed to tailored the power to the needs of the mission. Prior to cut -down of the balloon, the panels can be retracted and stowed compactly in the lower part of the gondola. This will protect the array during landing, allowing the array to be reused on subsequent flights.

  7. ST monitoring for myocardial ischemia during and after coronary angioplasty.

    Science.gov (United States)

    Mizutani, M; Ben Freedman, S; Barns, E; Ogasawara, S; Bailey, B P; Bernstein, L

    1990-08-15

    We performed 12-lead electrocardiographic monitoring in 97 patients during coronary angioplasty (PTCA) of a single vessel to correlate ischemic ST changes with clinical, angiographic and coronary hemodynamic variables and to determine the optimum lead or combination of leads for their detection. Ischemia (chest pain or ST change, group A) occurred in 79 patients (80%), but in only 15 of 23 patients (65%) with collaterals (p less than 0.05). Ischemia occurred more often in left anterior descending and left circumflex PTCA than right coronary PTCA, but pain was the only manifestation more often in left circumflex and right coronary PTCA. Ischemic ST change was silent in 16% and this proportion did not differ in clinical or angiographic groups except for diabetes with 3 of 5 (60%) having silent ischemia (p less than 0.05). Patients in group A (ischemia) compared to group B (no ischemia) had less severe lesions (85 +/- 9 vs 91 +/- 7%, p less than 0.01), higher transstenotic gradients (62 +/- 19 vs 53 +/- 9 mm Hg, p less than 0.05) and lower distal occluded pressures (24 +/- 11 vs 33 +/- 10 mm Hg, p less than 0.01), suggesting less collateral flow. Compared with a 12-lead electrocardiogram, the best single lead for detecting ST change during PTCA in each artery had a sensitivity of 80% and this increased to 93% using the best 2 leads. The best 3 leads (V3/III/V5 for left anterior descending and III/V2/V5 for right coronary and left circumflex) increased sensitivity to 100%.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Medical angioplasty - Hope and expectations: An optimistic overview

    Directory of Open Access Journals (Sweden)

    Mohammed F Abdul-Mohsen

    2011-01-01

    Full Text Available Primary and secondary prevention of cardiovascular diseases (CVD are markedly overlooked worldwide. The use of these kinds of preventive methods will greatly improve outcome of or even reverse major CVD, especially coronary atherosclerosis. Comprehensive lifestyle changes combined with aggressive medical therapy [lipid lowering agents "statins", antiplatelet agents, beta-blockers and angiotensin-converting enzyme inhibitors] for patients suffering from coronary heart disease significantly reduce all major adverse cardiovascular events (MACE, especially in those with stable coronary artery disease (CAD, even if their coronary lesions are significant. The main mechanistic pathways for the significant reduction of MACE are: Stabilization of atheromatous plaques through endothelial function reparation, strengthening of the fibrous cap of the atheromatous plaque and reduction of atheroma burden, i.e., reversal of the process of coronary artery stenosis, the great dream of "medical angioplasty". Despite the compelling data indicating the great beneficial effects of both primary and secondary prevention of coronary atherosclerosis, the US national survey data reveals that only a minority of patients eligible by guidelines for these therapies in fact receive them. Hence, we strongly believe that our main duties as cardiologists is to improve the up-to-date knowledge of the practicing physicians about utility of aggressive medical therapy for both prevention and reversal of CVD, and also to promote useful primary and secondary prevention programs among physicians and patients. Meanwhile, further improvement and refinement of the current therapeutic modalities and introduction of new modalities for the management of lipid parameters other than LDL-C, such as HDL-C, triglyceride, lipoprotein (a, LDL particle size and susceptibility to oxidation may add further favourable effects in prevention and reversal of atherosclerotic process. Cardiologists should be

  9. [Exercise tolerance in patients after successful percutaneous transluminal coronary angioplasty].

    Science.gov (United States)

    Tsumoto, S; Nakagawa, Y; Asakuma, S; Naruse, H; Komasa, N; Ohyanagi, M; Tateishi, J; Yasutomi, N; Fujitani, K; Iwasaki, T

    1991-01-01

    In 32 patients with successful percutaneous transluminal coronary angioplasty (PTCA), we performed treadmill exercise tests (TMET) before and about one month after PTCA to assess the correlation between the improvement in coronary artery lesions and exercise tolerance. Either the Bruce protocol (B: n = 12) or the modified Bruce protocol (MB: n = 20) was used; with the latter being applied to patients whose cardiac function seemed depressed. In 15 patients, oxygen consumption (VO2) was measured by analyzing the expired gases, 13 patients underwent exercise thallium-201 myocardial perfusion scintigraphy before and after PTCA, whose results were compared with those of TMET. In both B and MB protocols, the treadmill walking time was significantly prolonged after PTCA, compared to that before PTCA (B: 7.4 +/- 1.3 vs 9.5 +/- 1.9, MB: 11.4 +/- 3.5 vs 12.7 +/- 3.5 min). Heart rates (HR) and rate pressure products (RPP) were significantly increased after PTCA in both protocols (HR B: 139 +/- 18 vs 154 +/- 17, MB: 121 +/- 20 vs 137 +/- 19 bpm, RPP B: 26,500 +/- 5,600 vs 30,300 +/- 6,700, MB: 19,400 +/- 6,200 vs 22,700 +/- 6,600 mmHg.bpm), however, systolic blood pressure did not change significantly after PTCA in either protocol. While there was a significant improvement in VO2 after PTCA (21.6 +/- 6.3 vs 25.7 +/- 4.2 ml/kg/min), the O2-pulse remained unchanged. Thallium-201 myocardial scintigraphy revealed improvement of myocardial perfusion in 8 of the 13 cases examined.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1841916

  10. Prediction of Prolonged Hemodynamic Instability During Carotid Angioplasty and Stenting

    Science.gov (United States)

    Rhim, Jong Kook; Park, Jeong Jin; Choi, Hyuk Jai; Cho, Young Dae; Sheen, Seung Hun; Jang, Kyung-Sool

    2016-01-01

    Purpose The aim of this study was to assess the risk factors of prolonged hemodynamic instability (HDI) after carotid angioplasty and stenting (CAS). Herein, a simplified predictive scoring system for prolonged HDI is proposed. Materials and Methods Sixty-six patients who had CAS from 2011 to 2016 at a single institution were evaluated. Prolonged HDI was defined as systolic blood pressure >160 mm Hg or <90 mm Hg or heart rate <50 beats/min, lasting over 30 minutes despite medical treatments. For the study, clinical data and radiologic data, including plaque morphology and stenosis were analyzed. Results Prolonged HDI was observed in 21 patients (31.8%). Multivariable analysis revealed that calcification (OR, 6.726; p=0.006), eccentric stenosis (OR, 3.645; p=0.047) and extensive plaque distribution (OR, 7.169; p=0.006) were related to prolonged HDI. According to these results, a simplified scoring scale was proposed based on the summation of points: 2 points for calcified plaque, 2 points for extensive plaque distribution, and 1 point for eccentric stenosis. The percentages of prolonged HDI according to the total score were as follows: score 0, 8.7%; score 1, 20.0%; score 2, 38.5%; score 3, 72.7%; score 4, 66.7%; score 5, 100%. From the analysis, the total score in patients with prolonged HDI was significantly higher than those without prolonged HDI (p<0.001). Conclusion Prolonged HDI can be associated with calcification of plaque, eccentric stenosis and extensive plaque distribution, and a simplified scoring system enables prediction of prolonged HDI according to our cohort.

  11. Fluoroscopically Guided Balloon Dilation for Postintubation Tracheal Stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woong Hee; Kim, Jin Hyoung, E-mail: m1fenew@daum.net; Park, Jung-Hun [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of)

    2013-10-15

    Purpose: Little was known about the safety and long-term efficacy of fluoroscopically guided balloon dilation for postintubation tracheal stenosis. The purpose of this study was to evaluate the safety and long-term efficacy of fluoroscopically guided balloon dilation in patients with postintubation tracheal stenosis. Methods: From February 2000 to November 2010, 14 patients underwent fluoroscopically guided balloon dilation for postintubation tracheal stenosis. Technical success, clinical success, and complications were evaluated. Patients were followed up for recurrent symptoms. Results: In all patients, fluoroscopically guided balloon dilation was technically and clinically successful with no major complications. Following the initial procedure, six patients (43 %) remained asymptomatic during a follow-up period. Obstructive symptoms recurred in eight patients (57 %) within 6 months (mean, 1.7 months), who were treated with repeat balloon dilation (n = 4) and other therapies. Of the four patients who underwent repeat balloon dilation, three became asymptomatic. One patient became asymptomatic after a third balloon dilation. On long-term (mean, 74 months) follow-up, 71 % of patients experienced relief of symptoms following fluoroscopically guided balloon dilation. Conclusions: Fluoroscopically guided balloon dilation may be safe, is easy to perform, and resulted in effective treatment in patients with postintubation tracheal stenosis.

  12. Acoustical characterization of exploding hydrogen-oxygen balloons.

    Science.gov (United States)

    Vernon, Julia A; Gee, Kent L; Macedone, Jeffrey H

    2012-03-01

    Exploding hydrogen-oxygen balloons are popular chemistry demonstrations. Although initial research experimentally quantified potential hearing risk via analysis of peak levels [K. L. Gee et al., J. Chem. Educ. 87, 1039-1044 (2010)], further waveform and spectral analyses have been conducted to more fully characterize these impulsive noise sources. While hydrogen-only balloons produce inconsistent reactions and relatively low, variable levels, stoichiometrically mixed hydrogen-oxygen balloons produce consistent high-amplitude noise waveforms. Preliminary consideration is also given to the potential use of these exploding balloons in architectural acoustics applications. PMID:22423815

  13. HEMOPERFUSION DURING CORONARY ANGIOPLASTY - 1ST EUROPEAN EXPERIENCE WITH A NEW HEMOPERFUSION PUMP

    NARCIS (Netherlands)

    DEMUINCK, ED; MEEDER, J; MAGIELSE, C; BOM, VJJ; VANDIJK, RB; VERKERKE, GJ; LIE, KI

    1994-01-01

    Hemolysis tests with fresh human blood were performed in vitro with a new 5 ml, piston-type hemoperfusion pump, designed to prevent myocardial ischemia during coronary angioplasty. Despite driving pressures greater than 3 atmospheres, shear stress greater than 200 Pa, turbulent pump flow, and the pr

  14. Iliac artery myointimal hyperplasia in rabbits submitted to angioplasty and treated with Moringa oleifera

    Directory of Open Access Journals (Sweden)

    Jânio Cipriano Rolim

    2016-02-01

    Full Text Available Objective: to assess post-angioplasty myointimal hyperplasia in iliac artery of rabbits treated with extract of Moringa oleifera leaves. Methods : we conducted a randomized trial in laboratory animals for five weeks of follow-up, developed in the Vivarium of Pharmaceutical Technology Laboratory of the Universidade Federal da Paraíba. We used rabbits from the New Zealand breed, subjected to a hypercholesterolemic diet and angioplasty of the external iliac artery, randomized into two groups: M200 Group (n=10 - rabbits treated with 200mg/kg/day of Moringa oleifera leaves extract orally; SF group (n=10 - rabbits treated with 0.9% saline orally. After five weeks, the animals were euthanized and the iliac arteries prepared for histology. Histological sections were analyzed by digital morphometry. Statistical analysis was performed using the Student's t test. The significance level was 0.05. Results : there was no significant difference in myointimal hyperplasia between M200 and SF groups when comparing the iliac arteries submitted to angioplasty. Conclusion : there was no difference of myointimal hyperplasia between groups treated with saline and Moringa oleifera after angioplasty.

  15. Five-year follow-up of angiographic disease progression after medicine, angioplasty, or surgery

    OpenAIRE

    Oliveira Sergio A; Stolf Noedir A; Góis Aécio FT; Soares Paulo R; Lopes Neuza; Borges Jorge; Hueb Whady A.; Ramires Jose AF

    2010-01-01

    Abstract Background Progression of atherosclerosis in coronary artery disease is observed through consecutive angiograms. Prognosis of this progression in patients randomized to different treatments has not been established. This study compared progression of coronary artery disease in native coronary arteries in patients undergoing surgery, angioplasty, or medical treatment. Methods Patients (611) with stable multivessel coronary artery disease and preserved ventricular function were randoml...

  16. Short- and long-term functional effects of percutaneous transluminal angioplasty in hemodialysis vascular access

    NARCIS (Netherlands)

    J. van der Linden (Joke); J.H. Smits (Johannes); J.H. Assink (Jan Hendrik); D.W. Wolterbeek (Derk); J.J. Zijlstra (Jan); G.H.T. de Jong (Gijs); M.A. van den Dorpel; P.J. Blankestijn (Peter)

    2002-01-01

    textabstractThe efficacy of percutaneous transluminal angioplasty (PTA) is usually expressed as the angiographic result. Access flow (Qa) measurements offer a means to quantify the functional effects. This study was performed to evaluate the short-term functional and angiographic e

  17. Late hemodynamic failure following percutaneous transluminal angioplasty for long and multifocal femoropopliteal stenoses

    DEFF Research Database (Denmark)

    Jørgensen, B; Tønnesen, K H; Holstein, P

    1991-01-01

    The outcome of percutaneous transluminal angioplasty (PTA) was evaluated for treatment of 87 limbs with femoropopliteal stenoses, including 55 short stenoses (2.4 +/- 1.6 cm, mean +/- SD), seven single long stenoses (10.4 +/- 2.0 cm), and 25 multifocal stenoses (2.1 +/- 1.6 cm), where two to four...

  18. Comparison between primary angioplasty and thrombolytic therapy on erectile dysfunction after acute ST elevation myocardial infarction

    Institute of Scientific and Technical Information of China (English)

    Ramazan Akdemir; Ekrem Yeter; (O)zlem Karakurt; Salih Orcan; Nihat Karakoyunlu; Mustafa Mucahit Balci; Levent Sa(g)nak; Hamit Ersoy; Mehmet Bulent Vatan; Harun Kilic

    2012-01-01

    Acute ST elevation myocarclial infarction has high mortality and morbidity rates.The majority of patients with this condition face erectile dysfunction in addition to other health problems,In this study,we aimed to investigate the effects of two different reperfusion strategies,primary angioplasty and thrombolytic therapy,on the prevalence of erectile dysfunction after acute myocardial infarction.Of the 71 patients matching the selection criteria,45 were treated with primary coronary angioplasty with stenting,and 26 were treated with thrombolytic agents.Erectile function was evaluated using the International Index of Erectile Function in the hospital to characterize each patient's sexual function before the acute myocardial infarction and 6 months after the event.The time required to restore blood flow to the artery affected by the infarct was found to be associated with the occurrence of erectile dysfunction after acute myocardial infarction.The increase in the prevalence of erectile dysfunction after acute myocardial infarction was 44.4% in the angioplasty group and 76.9% in the thrombolytic therapy group (P=0.008).In conclusion,this study has shown that reducing the time of reperfusion decreases the erectile dysfunction prevalence,and primary angioplasty is superior to thrombolytic therapy for decreasing the prevalence of erectile dysfunction after acute myocardial infarction.

  19. The prognostic importance of heart failure and age in patients treated with primary angioplasty

    NARCIS (Netherlands)

    Henriques, JPS; Zijlstra, F; de Boer, MJ; van't Hof, AWJ; Gosselink, ATM; Suryapranata, H; Hoorntje, JCA; Dambrink, Jan Hendrik Everwijn

    2003-01-01

    Background: Effective risk stratification is essential in the management of patients with acute myocardial infarction. Available models have not yet been studied and validated in patients treated with primary angioplasty for acute myocardial infarction. Methods: The prognostic value of heart failure

  20. Assessment of percutaneous transluminal coronary angioplasty by quantitative coronary angiography: diameter versus densitometric area measurements

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); J.H.C. Reiber (Johan); W. Wijns (William); M.J.B.M. van den Brand (Marcel); C.J. Kooijman; H.J. ten Katen (Harald); P.G. Hugenholtz (Paul)

    1984-01-01

    textabstractCineangiograms of 138 patients who underwent percutaneous transluminal coronary angioplasty (PTCA) were analyzed with a computer-based coronary angiography analysis system. The results before and after dilatation are presented. In a first study group (120 patients), the severity of the o

  1. Drug therapy or coronary angioplasty for the treatment of coronary artery disease : New insights

    NARCIS (Netherlands)

    Amoroso, G; Van Boven, AJ; Crijns, HJGM

    2001-01-01

    Background In the last decade percutaneous transluminal coronary angioplasty has become a very popular strategy For the treatment of coronary artery disease, although its efficacy in reducing ischemic events and the subsequent need for revascularization has yet to be proved. Methods We reviewed the

  2. A clinical trial comparing primary coronary angioplasty with tissue plasminogen activator for acute myocardial infarction

    NARCIS (Netherlands)

    M.L. Simoons (Maarten); S.G. Ellis (Stephen)

    1997-01-01

    textabstractBACKGROUND: Among physicians who treat patients with acute myocardial infarction, there is controversy about the magnitude of the clinical benefit of primary (i.e., immediate) coronary angioplasty as compared with thrombolytic therapy. METHODS: As part of the Global Use of Strategies to

  3. High-fidelity translesional pressure gradients during percutaneous transluminal coroanry angioplasty: correlation with quantitative coronary angiography

    NARCIS (Netherlands)

    C. Lamm; M. Dohnal; P.W.J.C. Serruys (Patrick); H.U. Emanuelsson (Hakan)

    1993-01-01

    textabstractA fiberoptic pressure sensor mounted on an 0.018-inch guidewire (Pressure Guide) was used to measure the transstenotic pressure gradient in 30 patients undergoing percutaneous transluminal coronary angioplasty (PTCA) with lesions considered suitable for quantitative coronary angiographic

  4. Short- and long-term functional effects of percutaneous transluminal angioplasty in hemodialysis vascular access

    NARCIS (Netherlands)

    Van der Linden, J; Smits, JHM; Wolterbeek, DW; Zijlstra, JJ; De Jong, GHT; Van den Dorpel, MA; Blankestijn, PJ

    2002-01-01

    The efficacy of percutaneous transluminal angioplasty (PTA) is usually expressed as the angiographic result. Access flow (Qa) measurements offer a means to quantify the functional effects. This study was performed to evaluate the short-term functional and angiographic effects of PTA and to determine

  5. Immediate versus deferred coronary angioplasty in non-ST-segment elevation acute coronary syndromes

    NARCIS (Netherlands)

    R.K. Riezebos; E. Ronner; E. ter Bals; T. Slagboom; P.C. Smits; J.M. ten Berg; F. Kiemeneij; G. Amoroso; M.S. Patterson; M.J. Suttorp; J.G.P. Tijssen; G.J. Laarman

    2009-01-01

    BACKGROUND: The field of acute coronary syndromes is characterised by an increasing tendency towards early invasive catheter-based diagnostics and therapeutics-a practice based on observational and retrospective data. OBJECTIVE: To compare immediate versus deferred angioplasty in patients with non-S

  6. Restenosis after coronary angioplasty: the paradox of increased lumen diameter and restenosis

    NARCIS (Netherlands)

    K.J. Beatt (Kevin); P.W.J.C. Serruys (Patrick); H.E. Luijten; B.J.W.M. Rensing (Benno); H. Suryapranata (Harry); P.J. de Feyter (Pim); M.J.B.M. van den Brand (Marcel); G-J. Laarman (GertJan); G.A. van Es (Gerrit Anne); J.R.T.C. Roelandt (Jos)

    1992-01-01

    textabstractRestenosis after coronary angioplasty is the single complication that most limits this revascularization procedure in clinical practice. The process is largely unpredictable and the lesion-related factors predisposing to restenosis are poorly understood, with little consensus in publishe

  7. Stratospheric composition from balloon based measurements

    Energy Technology Data Exchange (ETDEWEB)

    Mencaraglia, F.; Carli, B. [Ist. per le Ricerche sulle Onde Elettromagnetiche, Firenze (Italy); Bonetti, A.; Ciarpallini, P. [Univ. di Firenze (Italy); Carlotti, M.; Lepri, G. [Univ. di Bologna (Italy); Alboni, F.; Cortesi, U.; Ridolfi, M. [Fondazione per la Metereologia Applicata, Firenze (Italy)

    1995-12-31

    Measurements of the composition of the earth`s atmosphere is of fundamental importance for the study of atmospheric chemistry and for developing models that can predict the evolution of the atmosphere itself. Here, the chemical composition of the lower stratosphere has been measured using a polarizing interferometer operating in the far infrared and submillimetric spectral region. The instrument was flown three times (in 1992, 1993 and 1994) from the NSBF balloon base (Fort Sumner, New Mexico) in coincidence with overpasses of the UARS satellite, for a total of about 50 hours of measurements. In this paper the authors report some of the results obtained from the data analysis made up to now.

  8. Guidelines and Suggestions for Balloon Gondola Design

    Science.gov (United States)

    Franco, Hugo

    2016-01-01

    The Columbia Scientific Balloon Facility is responsible for ensuring that science payloads meet the appropriate design requirements. The ultimate goal is to ensure that payloads stay within the allowable launch limits as well as survive the termination event. The purpose of this presentation is to provide some general guidelines for Gondola Design. These include rules and reasons on why CSBF has a certain preference and location for certain components within the gondola as well as other suggestions. Additionally, some recommendations are given on how to avoid common pitfalls.

  9. General theory of kinetic ballooning modes

    International Nuclear Information System (INIS)

    The ballooning mode formalism, previously developed for the ideal MHD problem, is applied here to the kinetic problem in tokamaks. The general two-dimensional equation governing drift and trapped-electron eigenmodes reduces to a one-dimensional integral equation along the lines of force with the radial structure determined by a WKB procedure. Comparisons made between the present one-dimensional code and a previous two-dimensional code embodying identical physical assumptions indicate reasonable agreement. This correspondence holds both for the structure along the field line and for the radial structure in the special case of closely spaced turning points

  10. Pneumothorax, music and balloons: A case series

    Directory of Open Access Journals (Sweden)

    Shiferaw Dejene

    2013-01-01

    Full Text Available We describe two cases of spontaneous pneumothorax in young healthy adults with no underlying structural lung disease. The onset of pneumothorax was following physical activity including playing musical instruments and blowing of balloons. There is sparse data evaluating the pathophysiology of primary spontaneous pneumothorax in relation to increased mouth pressures. These cases highlight the possible physical effect of valsalva manoeuvre on transpulmonary pressures, and the potential risk of developing pneumothorax in otherwise healthy individuals. This aspect of pneumothorax development is worthy of further exploration, to better elucidate the mechanism and enhance our understanding of this common respiratory presentation.

  11. Thrombus aspiration catheter is a Dottering balloon.

    Science.gov (United States)

    Sheshagiri Rao, D; Barik, Ramachandra; Prasad, Akula Siva

    2016-01-01

    Coronary angiogram in a young man with history of STEMI with delayed presentation revealed subtotal occlusion of left anterior descending artery (LAD) with large thrombotic filling defect distal to the critical lesion. PCI was preferred without delay because of ongoing chest pain. Several runs of thrombus aspiration failed to detect any visible thrombus. However, the immediate angiogram after thrombus aspiration showed complete distal embolization of the thrombus which could have been achieved by Dottering or balloon dilatation. In contrary to the general perception, does thrombus aspiration push more thrombus than it can aspirate? PMID:27543477

  12. Ballooning Spiders: The Case for Electrostatic Flight

    CERN Document Server

    Gorham, Peter W

    2013-01-01

    We consider general aspects of the physics underlying the flight of Gossamer spiders, also known as ballooning spiders. We show that existing observations and the physics of spider silk in the presence of the Earth's static atmospheric electric field indicate a potentially important role for electrostatic forces in the flight of Gossamer spiders. A compelling example is analyzed in detail, motivated by the observed "unaccountable rapidity" in the launching of such spiders from H.M.S. Beagle, recorded by Charles Darwin during his famous voyage.

  13. Double-balloon endoscopy: Who needs it?

    DEFF Research Database (Denmark)

    Hendel, J.W.; Vilmann, P.; Jensen, T.

    2008-01-01

    Objective. Double-balloon endoscopy (DBE) made the small bowel accessible to inspection and therapy in its entirety. However, DBE is a time-consuming procedure that requires a highly skilled endoscopist, several nurses and - more often than not - anesthesiological support. This makes the selection...... of patients for DBE a pivotal point. The mainstay of this screening examination of the small bowel is capsule endoscopy (CE). The aim of this study was to describe the results of this screening procedure and the subsequent DBE in patients with suspected mid-gastrointestinal bleeding (MGIB). Material...

  14. Pneumothorax, music and balloons: A case series.

    Science.gov (United States)

    Dejene, Shiferaw; Ahmed, Fahim; Jack, Kastelik; Anthony, Arnorld

    2013-07-01

    We describe two cases of spontaneous pneumothorax in young healthy adults with no underlying structural lung disease. The onset of pneumothorax was following physical activity including playing musical instruments and blowing of balloons. There is sparse data evaluating the pathophysiology of primary spontaneous pneumothorax in relation to increased mouth pressures. These cases highlight the possible physical effect of valsalva manoeuvre on transpulmonary pressures, and the potential risk of developing pneumothorax in otherwise healthy individuals. This aspect of pneumothorax development is worthy of further exploration, to better elucidate the mechanism and enhance our understanding of this common respiratory presentation. PMID:23922614

  15. Flight Qualification of the NASA's Super Pressure Balloon

    Science.gov (United States)

    Cathey, Henry; Said, Magdi; Fairbrother, Debora

    Designs of new balloons to support space science require a number of actual flights under various flight conditions to qualify them to as standard balloon flight offerings to the science community. Development of the new Super Pressure Balloon for the National Aeronautics and Space Administration’s Balloon Program Office has entailed employing new design, analysis, and production techniques to advance the state of the art. Some of these advances have been evolutionary steps and some have been revolutionary steps requiring a maturing understanding of the materials, designs, and manufacturing approaches. The NASA Super Pressure Balloon development end goal is to produce a flight vehicle that is qualified to carry a ton of science instrumentation, at an altitude greater than 33 km while maintaining a near constant pressure altitude for extended periods of up to 100 days, and at any latitude on the globe. The NASA’s Balloon Program Office has pursued this development in a carefully executed incremental approach by gradually increasing payload carrying capability and increasing balloon volume to reach these end goal. A very successful test flight of a ~200,700 m3 balloon was launch in late 2008 from Antarctica. This balloon flew for over 54 days at a constant altitude and circled the Antarctic continent almost three times. A larger balloon was flown from Antarctica in early 2011. This ~422,400 m3 flew at a constant altitude for 22 days making one circuit around Antarctica. Although the performance was nominal, the flight was terminated via command to recover high valued assets from the payload. The balloon designed to reach the program goals is a ~532,200 m3 pumpkin shaped Super Pressure Balloon. A test flight of this balloon was launched from the Swedish Space Corporation’s Esrange Balloon Launch Facilities near Kiruna, Sweden on 14 August, 2012. This flight was another success for this development program. Valuable information was gained from this short test

  16. Long-term outcome of primary angioplasty compared with fibrinolysis across age groups: a Danish Multicenter Randomized Study on Fibrinolytic Therapy Versus Acute Coronary Angioplasty in Acute Myocardial Infarction (DANAMI-2) substudy

    DEFF Research Database (Denmark)

    Fosbøl, Emil Loldrup; Thune, Jens Jakob; Kelbaek, Henning;

    2008-01-01

    BACKGROUND: Primary angioplasty in patients with acute ST-elevation myocardial infarction has been shown to be superior to fibrinolysis. Whether elderly patients have the same long-term benefit from angioplasty, compared with fibrinolysis, as younger patients is unknown. METHODS: The effect...... of angioplasty versus fibrinolysis was investigated in 1,572 patients from the DANAMI-2 study across age groups. End points were total mortality and a composite end point of death, reinfarction, or disabling stroke. Follow-up was 3 years. RESULTS: Increasing age was associated with mortality (adjusted hazard...... ratio [HR] 2.45 per 10 year increment, 95% confidence interval [CI] 1.78-3.37, P angioplasty over fibrinolysis on the combined outcome was independent of age: patients aged

  17. Endovascular brachytherapy to prevent restenosis after angioplasty; Endovaskulaere Brachytherapie in der Restenoseprophylaxe nach Angioplastie und Stentimplantation: Eine Uebersicht

    Energy Technology Data Exchange (ETDEWEB)

    Wohlgemuth, W.A.; Bohndorf, K. [Klinikum Augsburg (Germany). Klinik fuer Diagnostische Radiologie und Neuroradiologie

    2003-02-01

    Endovascular radiotherapy is the first effective prophylaxis of restenosis after percutaneous transluminal angioplasty (PTA) and stenting. The FDA recently approved two devices for the delivery of intracoronary radiation following coronary artery stenting. Published multicenter, double-blind, randomized trials of intracoronary radiation therapy report good results for preventing in-stent restenosis, while the data for the peripheral circulation are still inconclusive. Beta-emitters are easier applicable and probably also safer, whereas gamma-emitters have been more extensively evaluated clinically so far. Primary indication for endovascular brachytherapy are patients at high risk for restenosis, such as previous restenoses, in-stent hyperplasia, long stented segment, long PTA lesion, narrow residual vascular lumen and diabetes. Data from coronary circulation suggest a safety margin of at least 4 to 10 mm at both ends of the angioplastic segment to avoid edge restenosis. To prevent late thrombosis of the treated coronary segment, antiplatelet therapy with clopidogrel and aspirin are recommended for at least 6 months after PTA and for 12 months after a newly implanted stent. An established medication regimen after radiotherapy of peripheral arteries is still lacking. (orig.) [German] Die endovaskulaere Radiotherapie stellt das erste erfolgreiche Therapiekonzept in der Restenoseprophylaxe nach PTA und Stentimplantation dar. Am 3.11.2000 hat die amerikanische Food and Drug Administration erstmalig zwei Brachytherapiegeraete zur Restenoseprophylaxe nach Koronararterien-Stenting zugelassen. Grosse multizentrische, kontrollierte Studien wurden fuer das koronare Stromgebiet mit positiven Ergebnissen publiziert, die Datenlage im peripheren Stromgebiet ist noch ungenuegend. Beta-Strahler bieten Vorteile in der Anwendung, moeglicherweise auch in der Sicherheit, Gamma-Strahler dagegen sind besser klinisch evaluiert. Die primaere Indikation zur endovaskulaeren Brachytherapie

  18. Reversible transient apical ballooning syndrome with coronary lesions

    Institute of Scientific and Technical Information of China (English)

    Yunshan Cao; Min Zhang; Xiang Li; Ping Xie; Lynn Cronin

    2009-01-01

    Transient apical ballooning syndrome(Tako-Tsubo syndrome or ampulla cardiomyopathy) occurs predominantly in women over 60 years of age with a history of recent physical or psychological stress. We present a case of a male patient with reversible transient apical ballooning syndrome with significant coronary lesions and other ECG changes that did not explain the clinical symptoms.

  19. 21 CFR 870.1350 - Catheter balloon repair kit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the... effect the repair or replacement. (b) Classification. Class III (premarket approval). (c) Date PMA...

  20. Recent developments in the scientific ballooning in India

    Science.gov (United States)

    Manchanda, R.; Sreenivasan, S.; Subbarao, J.; Kumar, P.

    RECENT DEVELOPMENTS IN THE SCIENTIFIC BALLOONING IN INDIA R. K. Manchanda1, S. Sreenivasan2, J. V. Subbarao2, P. R. Kumar2 1. Tata Institute of Fundamental Research Colaba, Mumbai-400 005, India. 2. TIFR Balloon Facility, PO Box 5, ECIL Post Office, Hyderabad-500 762, India ravi@tifr.res.in/FAX: +91-22-2152110 National Balloon facility operated by TIFR in Hyderabad, India is the only one of its kind in the world, which combines both, the in-house balloon production and a complete flight support for scientific ballooning. In the past few years we executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to 780,000 m3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years and the results of the test flight conducted to qualify new sub systems will be presented.

  1. Influence of a history of smoking on short term (six month) clinical and angiographic outcome after successful coronary angioplasty

    NARCIS (Netherlands)

    A.G. Violaris (Andonis); A. Thury (Attila); R. Melkert (Rein); P.W.J.C. Serruys (Patrick); E.S. Regar (Eveline)

    2000-01-01

    textabstractOBJECTIVES: To assess the influence of smoking on restenosis after coronary angioplasty. DESIGN AND PATIENTS: The incidence of smoking on restenosis was investigated in 2948 patients. They were prospectively enrolled in four major restenosis trials in which quantitative

  2. EUSO-Balloon: The first flight

    Science.gov (United States)

    Scotti, Valentina; Osteria, Giuseppe

    2016-07-01

    EUSO-Balloon is a pathfinder mission for JEM-EUSO, the near-UV telescope proposed to be installed on board the International Space Station (ISS). The main objective of this pathfinder mission is to perform a full scale end-to-end test of all the key technologies of JEM-EUSO detectors and to measure the UV background. The JEM-EUSO instrument consists of UV telescope designed to focus the signal of the UV tracks generated by Extreme Energy Cosmic Rays propagating in Earth's atmosphere, onto a finely pixelized UV camera. The EUSO-Balloon instrument, smaller than the one designed for the ISS, was launched on August 2014 from Timmins (Ontario, Canada). The flight lasted about five hours and the instrument reached a float altitude of about 40 km. From this altitude the telescope registered, at a rate of 400 000 frames/s, the nightglow background on forests, lakes and clouds, as well as city lights and artificial air showers tracks generated by means of a laser installed on an helicopter flying inside its field of view. In this contribution we will describe the instrument and its performance during the first flight.

  3. Spectrum of the ballooning Schroedinger equation

    International Nuclear Information System (INIS)

    The ballooning Schroedinger equation (BSE) is a model equation for investigating global modes that can, when approximated by a Wentzel-Kramers-Brillouin (WKB) ansatz, be described by a ballooning formalism locally to a field line. This second order differential equation with coefficients periodic in the independent variable θk is assumed to apply even in cases where simple WKB quantization conditions break down, thus providing an alternative to semiclassical quantization. Also, it provides a test bed for developing more advanced WKB methods: e.g. the apparent discontinuity between quantization formulae for open-quotes trappedclose quotes and open-quotes passingclose quotes modes, whose ray paths have different topologies, is removed by extending the WKB method to include the phenomena of tunnelling and reflection. The BSE is applied to instabilities with shear in the real part of the local frequency, so that the dispersion relation is inherently complex. As the frequency shear is increased, it is found that trapped modes go over to passing modes, reducing the maximum growth rate by averaging over θk

  4. Balloon concepts for scientific investigation of Mars and Jupiter

    Science.gov (United States)

    Ash, R. L.

    1979-01-01

    Opportunities for scientific investigation of the atmospheric planets using buoyant balloons have been explored. Mars and Jupiter were considered in this study because design requirements at those planets bracket nominally the requirements at Venus, and plans are already underway for a joint Russian-French balloon system at Venus. Viking data has provided quantitative information for definition of specific balloon systems at Mars. Free flying balloons appear capable of providing valuable scientific support for more sophisticated Martian surface probes, but tethered and powered aerostats are not attractive. The Jovian environment is so extreme, hot atmosphere balloons may be the only scientific platforms capable of extended operations there. However, the estimated system mass and thermal energy required are very large.

  5. An overview of instrumentation capabilities for Scientific ballooning in India

    Science.gov (United States)

    Devarajan, Anand; Reddy Vizapur, Anmi; Rao Tanneeru, Venkateswara; Bangaru, Kapardhi; Trivedi, Dharmesh; Rodi, Ashish; Ojha, Devendra; Koli, Santosh

    2016-07-01

    The Balloon Facility of Tata Institute of Fundamental Research (TIFR-BF) in India, launches scientific balloons for research in the field of astronomy, astrobiology and atmospheric sciences. TIFR-BF not only has the capability to design, fabricate and launch zero-pressure balloons, but also provide operational and engineering support for launching them. The Control Instrumentation Group (CIG) at the balloon facility handles all electronics related to telemetry, telecommand, tracking, real-time data display, data storage, air-safety and payload recovery. In the recent past, it has designed and developed customized electronics and payload orientation mechanism to meet specific experimental objectives. Small, inexpensive and rugged industrial grade radio data modems were successfully deployed in balloon flights for low bit rate data and image telemetry. This paper will provide an overview and in-flight performance of some of the recent developments in instrumentation and electronics systems. Our plans for future upgradations will also be discussed.

  6. The ballooning of fuel cladding tubes: theory and experiment

    International Nuclear Information System (INIS)

    Under some conditions, fuel clad ballooning can result in considerable strain before rupture. If ballooning were to occur during a loss-of-coolant accident (LOCA), the resulting substantial blockage of the sub-channel would restrict emergency core cooling. However, circumferential temperature gradients that would occur during a LOCA may significantly limit the average strain at failure. Understandably, the factors that control ballooning and rupture of fuel clad are required for the analysis of a LOCA. Considerable international effort has been spent on studying the deformation of Zircaloy fuel cladding under conditions that would occur during a LOCA. This effort has established a reasonable understanding of the factors that control the ballooning, failure time, and average failure strain of fuel cladding. In this paper, both the experimental and theoretical studies of the fuel clad ballooning are reviewed. (author)

  7. A New Paradigm in Space Based Experiments Using Rubber Balloons

    CERN Document Server

    Chakrabarti, Sandip K; Palit, Sourav; Chakraborty, Subhankar; Mondal, Sushanta; Bhattacharyya, Arnab; Middya, Susanta; Chakrabarti, Sonali

    2013-01-01

    Indian Centre for Space Physics is engaged in long duration balloon borne experiments with typical payloads less than ~ 3kg. Low cost rubber balloons are used. In a double balloon system, the booster balloon lifts the orbiter balloon to its cruising altitude where data is taken for a long time. Here we present results of muon detections and recent solar activities, including the light curves and flare spectra in the 20-100keV range. We not only show that we have successfully obtained several flares and there spectra at different altitudes, we also found that the high energy X-ray flux of strong flares at altitudes of 10-13 km (the flight altitude of commercial planes) could be more than the contribution due to cosmic rays.

  8. Correlating coating characteristics with the performance of drug-coated balloons--a comparative in vitro investigation of own established hydrogel- and ionic liquid-based coating matrices.

    Directory of Open Access Journals (Sweden)

    Sebastian Kaule

    Full Text Available Drug-coated balloons (DCB, which have emerged as a therapeutic alternative to drug-eluting stents in percutaneous cardiovascular intervention, are well described with regard to clinical efficacy and safety within a number of clinical studies. In vitro studies elucidating the correlation between coating additive and DCB performance are however rare but considered important for the understanding of DCB requirements and the improvement of established DCB. In this regard, we examined three different DCB-systems, which were developed in former studies based on the ionic liquid cetylpyridinium salicylate, the body-own hydrogel hyaluronic acid and the pharmaceutically well-established hydrogel polyvinylpyrrolidone, considering coating morphology, coating thickness, drug-loss, drug-transfer to the vessel wall, residual drug-concentration on the balloon surface and entire drug-load during simulated use in an in vitro vessel model. Moreover, we investigated particle release of the different DCB during simulated use and determined the influence of the three coatings on the mechanical behavior of the balloon catheter. We could show that coating characteristics can be indeed correlated with the performance of DCB. For instance, paclitaxel incorporation in the matrix can reduce the drug wash-off and benefit a high drug transfer. Additionally, a thin coating with a smooth surface and high but delayed solubility can reduce drug wash-off and decrease particle burden. As a result, we suggest that it is very important to characterize DCB in terms of mentioned properties in vitro in addition to their clinical efficacy in order to better understand their function and provide more data for the clinicians to improve the tool of DCB in coronary angioplasty.

  9. Long term results of endovascular treatment in renal arterial stenosis from Takayasu arteritis: Angioplasty versus stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hong Suk, E-mail: hongsukpark@gmail.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Do, Young Soo, E-mail: ysdo@skku.edu [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Kim, Duk-Kyung, E-mail: dukkyung.kim@samsung.com [Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, Sung Wook, E-mail: sw.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Shin, Sung Wook, E-mail: sw88.shin@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Cho, Sung Ki, E-mail: sungkismc@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Hyun, Dongho, E-mail: mesentery.hyun@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, In Wook, E-mail: inwook.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of)

    2013-11-01

    Purpose: To retrospectively evaluate and compare the long term patency and antihypertensive effect of angioplasty and stent insertion in renal artery stenosis caused by Takayasu arteritis, with CT angiography and clinical follow-up. Materials and methods: We retrospectively analyzed and compared effects on hypertension and patency of renal artery in 16 patients (age ranging from 16 to 58 years, mean: 32.1 years) with renovascular hypertension caused by Takayasu arteritis who underwent endovascular treatment including angioplasty (n = 13) and stent placement (n = 9) for 22 stenotic renal arteries. Results: Technical success was 95% (21/22) without major complications. In the last follow-up CT angiogram (mean 85 ± 41 months), restenosis was 8% (1/12) in angioplasty and 66% (6/9) in stent. Patency rates of angioplasty were 100%, 91.7%, 91.7% and primary unassisted and primary assisted patency rates of stent placement were 55.6%, 33.3%, 33.3% and 88.9%, 66.7%, 55.6% at 1-, 3- and 5-years, respectively. In clinical follow-up (mean 120 ± 37.8 months, range 48–183 months), beneficial effects on hypertension were obtained in 87% of patients (13/15) and there was no significant difference between the patients who were treated by only angioplasty and the patients who received stent placement in at least one renal artery, regardless of whether or not angioplasty had been performed in the other renal artery. Conclusion: Compared with stent placement, angioplasty demonstrated better long term patency and similar clinical benefit on renovascular hypertension in renal artery stenosis of Takayasu arteritis. We suggest that stent placement should be reserved for obvious angioplasty failure.

  10. Long term results of endovascular treatment in renal arterial stenosis from Takayasu arteritis: Angioplasty versus stent placement

    International Nuclear Information System (INIS)

    Purpose: To retrospectively evaluate and compare the long term patency and antihypertensive effect of angioplasty and stent insertion in renal artery stenosis caused by Takayasu arteritis, with CT angiography and clinical follow-up. Materials and methods: We retrospectively analyzed and compared effects on hypertension and patency of renal artery in 16 patients (age ranging from 16 to 58 years, mean: 32.1 years) with renovascular hypertension caused by Takayasu arteritis who underwent endovascular treatment including angioplasty (n = 13) and stent placement (n = 9) for 22 stenotic renal arteries. Results: Technical success was 95% (21/22) without major complications. In the last follow-up CT angiogram (mean 85 ± 41 months), restenosis was 8% (1/12) in angioplasty and 66% (6/9) in stent. Patency rates of angioplasty were 100%, 91.7%, 91.7% and primary unassisted and primary assisted patency rates of stent placement were 55.6%, 33.3%, 33.3% and 88.9%, 66.7%, 55.6% at 1-, 3- and 5-years, respectively. In clinical follow-up (mean 120 ± 37.8 months, range 48–183 months), beneficial effects on hypertension were obtained in 87% of patients (13/15) and there was no significant difference between the patients who were treated by only angioplasty and the patients who received stent placement in at least one renal artery, regardless of whether or not angioplasty had been performed in the other renal artery. Conclusion: Compared with stent placement, angioplasty demonstrated better long term patency and similar clinical benefit on renovascular hypertension in renal artery stenosis of Takayasu arteritis. We suggest that stent placement should be reserved for obvious angioplasty failure

  11. Salvage living donor liver transplantation after percutaneous transluminal angioplasty for recurrent Budd-Chiari syndrome: a case report

    Directory of Open Access Journals (Sweden)

    Mitoro Akira

    2011-03-01

    Full Text Available Abstract Introduction Budd-Chiari syndrome is a very rare pathological entity that ultimately leads to liver failure. Several therapeutic modalities, including percutaneous transluminal angioplasty, have been attempted to save the life of patients with Budd-Chiari syndrome. Few reports have described a salvage living donor liver transplantation performed after percutaneous transluminal angioplasty in a patient with acute Budd-Chiari syndrome. Case presentation A 26-year-old Japanese man developed severe progressive manifestations, such as massive ascites and hematemesis due to rupture of esophageal varices. After making several investigations, we diagnosed the case as Budd-Chiari syndrome. We first performed percutaneous transluminal angioplasty to dilate a short-segment stenosis of his inferior vena cava. The first percutaneous transluminal angioplasty greatly improved the clinical manifestations. However, after a year, re-stenosis was detected, and a second percutaneous transluminal angioplasty failed to open the severe stricture of his inferior vena cava. Since our patient had manifestations of acute liver failure, we decided to perform salvage living donor liver transplantation from his brother. The transplantation was successfully performed and all clinical manifestations were remarkably alleviated. Conclusion In cases of recurrent Budd-Chiari syndrome, the blocked hepatic venous outflow is not always relieved, even with invasive therapies. We have to take into account the possibility of adopting alternative salvage therapies if the first therapeutic modalities fail. When invasive therapy such as percutaneous transluminal angioplasty fails, liver transplantation should be considered as an alternative option.

  12. Tratamiento del vasoespasmo cerebral asociado a hemorragia subaracnoidea espontánea mediante angioplastia percutánea con balón: reporte de tres casos Treatment of cerebral vasospasm associated with subarachnoid hemorrhage by means of percutaneous balloon agioplasty: report of three cases

    Directory of Open Access Journals (Sweden)

    Carlos Mario Jiménez Yepes

    2002-03-01

    Full Text Available Reportamos el uso de la angioplastia percutánea con balón en tres pacientes con diagnóstico de vasoespasmo cerebral secundario a hemorragia subaracnoidea espontánea. Todos los pacientes estaban en mala condición clínica neurológica pero dentro de la ventana terapéutica para isquemia cerebral. El tratamiento fue considerado exitoso tanto en términos angiográficos como clínicos. La terapia endovascular mediante la angioplastia cerebral percutánea con balón es una herramienta útil en el vasoespasmo cerebral, en pacientes debidamente seleccionados y que estén dentro de la ventana terapéutica, que parece ser de doce horas luego de instalados los signos y síntomas. Succesful treatment of cerebral vasospasm by using percutaneous balloon angioplasty is reported in three cases. All patients were in bad condition with a short therapeutic window. All of them had a good recovery, both in terms of angiographic and clinical criteria. Use of endovascular therapy of spastic vessels by means of balloon percutaneous angioplasty in selected patients, is a good choice for treatment of cerebral vasospasm associated with spontaneous subarachnoid hemorrhage.

  13. Microgravity combustion experiment using high altitude balloon.

    Science.gov (United States)

    Kan, Yuji

    In JAXA, microgravity experiment system using a high altitude balloon was developed , for good microgravity environment and short turn-around time. In this publication, I give an account of themicrogravity experiment system and a combustion experiment to utilize the system. The balloon operated vehicle (BOV) as a microgravity experiment system was developed from 2004 to 2009. Features of the BOV are (1) BOV has double capsule structure. Outside-capsule and inside-capsule are kept the non-contact state by 3-axis drag-free control. (2) The payload is spherical shape and itsdiameter is about 300 mm. (3) Keep 10-4 G level microgravity environment for about 30 seconds However, BOV’s payload was small, and could not mount large experiment module. In this study, inherits the results of past, we established a new experimental system called “iBOV” in order toaccommodate larger payload. Features of the iBOV are (1) Drag-free control use for only vertical direction. (2) The payload is a cylindrical shape and its size is about 300 mm in diameter and 700 mm in height. (3) Keep 10-3-10-4 G level microgravity environment for about 30 seconds We have "Observation experiment of flame propagation behavior of the droplets column" as experiment using iBOV. This experiment is a theme that was selected first for technical demonstration of iBOV. We are conducting the flame propagation mechanism elucidation study of fuel droplets array was placed at regular intervals. We conducted a microgravity experiments using TEXUS rocket ESA and drop tower. For this microgravity combustion experiment using high altitude balloon, we use the Engineering Model (EM) for TEXUS rocket experiment. The EM (This payload) consists of combustion vessel, droplets supporter, droplets generator, fuel syringe, igniter, digital camera, high-speed camera. And, This payload was improved from the EM as follows. (1) Add a control unit. (2) Add inside batteries for control unit and heater of combustion

  14. Microcontroller uses in Long-Duration Ballooning

    Science.gov (United States)

    Jones, Joseph

    This paper discusses how microcontrollers are being utilized to fulfill the demands of long duration ballooning (LDB) and the advantages of doing so. The Columbia Scientific Balloon Facility (CSBF) offers the service of launching high altitude balloons (120k ft) which provide an over the horizon telemetry system and platform for scientific research payloads to collect data. CSBF has utilized microcontrollers to address multiple tasks and functions which were previously performed by more complex systems. A microcontroller system has been recently developed and programmed in house to replace our previous backup navigation system which is used on all LDB flights. A similar microcontroller system was developed to be independently launched in Antarctica before the actual scientific payload. This system's function is to transmit its GPS position and a small housekeeping packet so that we can confirm the upper level float winds are as predicted from satellite derived models. Microcontrollers have also been used to create test equipment to functionally check out the flight hardware used in our telemetry systems. One test system which was developed can be used to quickly determine if our communication link we are providing for the science payloads is functioning properly. Another system was developed to provide us with the ability to easily determine the status of one of our over the horizon communication links through a closed loop system. This test system has given us the capability to provide more field support to science groups than we were able to in years past. The trend of utilizing microcontrollers has taken place for a number of reasons. By using microcontrollers to fill these needs, it has given us the ability to quickly design and implement systems which meet flight critical needs, as well as perform many of the everyday tasks in LDB. This route has also allowed us to reduce the amount of time required for personnel to perform a number of the tasks required

  15. Impact of Age on Long-Term Outcome After Primary Angioplasty With Bare-Metal or Drug-Eluting Stent (From the DESERT Cooperation)

    DEFF Research Database (Denmark)

    De Luca, Giuseppe; Dirksen, Maurits T; Spaulding, Christian;

    2013-01-01

    stent thrombosis, which may be more pronounced in elderly patients. Therefore, the aim of this study was to evaluate the impact of age on outcome in patients with STEMI who underwent primary angioplasty with bare-metal stents (BMS) or DES. Our population comprised 6,298 patients who underwent primary...... angioplasty and stent implantation included in the Drug-Eluting Stent in Primary Angioplasty (DESERT) Cooperation database. Age was significantly associated with female gender (p...

  16. Failure of epoprostenol (prostacyclin, PGI2) to inhibit platelet aggregation and to prevent restenosis after coronary angioplasty: results of a randomised placebo controlled trial.

    OpenAIRE

    Gershlick, A H; Spriggins, D.; Davies, S W; Syndercombe Court, Y D; Timmins, J.; Timmis, A D; Rothman, M. T.; Layton, C; Balcon, R

    1994-01-01

    OBJECTIVE--To study the effect of epoprostenol (prostacyclin, PGI2) given before, during, and for 36 h after coronary angioplasty on restenosis at six months and to evaluate the transcardiac gradient of platelet aggregation before and after percutaneous transluminal coronary angioplasty (PTCA) in treated and placebo groups. DESIGN--Double blind placebo controlled randomised study. PATIENTS--135 patients with successful coronary angioplasty. METHODS--Intravenous infusion of PGI2 (4 ng/kg/ml) o...

  17. National Report France: The French Balloon Programme 2013-2016

    Science.gov (United States)

    Dubourg, V.; Vassaux, D.; Vargas, A.; Cocquerez, P.; Louvel, S.; Douchin, F.; Saccocio, M.; Mirc, F.

    2015-09-01

    With over 50 years' experience in the field, the French Centre National dEtudes Spatiales (CNES) goes on supporting a significant scientific ballooning program. In particular so because balloons still give a unique access to near space science. Over the past 6 years, most of the systems, beginning by the Zero Pressure Balloons, had to be renewed to comply with more stringent Safety constraints and to growing performance and reliability requirements from the scientific missions. This paper will give an overview of the CNES new capabilities and services for operational balloon activities, and their availability status. The scientific launch campaigns of the past two years will be presented. A focus will be made on the results of the Stratoscience 2014 flight campaign from Timmins, Ontario, using the NOSYCA command and control system for zero pressure balloons, qualified in 2013. The ChArMEx campaign (Chemistry-AeRosol Mediterranean Experiment) performed in 2013 from the Baleares islands and from the south of France, with Boundary Layer Pressurized Balloons will also be presented as well as the LOAC-VOLTAIRE experiment, carried out from Aire-sur-l'Adour (France), through the flights of 20 instrumented light expandable balloons. An outlook of the new stratospheric long duration flight systems currently studied at CNES will be given. The scientific launch campaigns and the main payloads in the study for the near future will also be presented.

  18. Graph-Based Path-Planning for Titan Balloons

    Science.gov (United States)

    Blackmore, Lars James; Fathpour, Nanaz; Elfes, Alberto

    2010-01-01

    A document describes a graph-based path-planning algorithm for balloons with vertical control authority and little or no horizontal control authority. The balloons are designed to explore celestial bodies with atmospheres, such as Titan, a moon of Saturn. The algorithm discussed enables the balloon to achieve horizontal motion using the local horizontal winds. The approach is novel because it enables the balloons to use arbitrary wind field models. This is in contrast to prior approaches that used highly simplified wind field models, such as linear, or binary, winds. This new approach works by discretizing the space in which the balloon operates, and representing the possible states of the balloon as a graph whose arcs represent the time taken to move from one node to another. The approach works with arbitrary wind fields, by looking up the wind strength and direction at every node in the graph from an arbitrary wind model. Having generated the graph, search techniques such as Dijkstra s algorithm are then used to find the set of vertical actuation commands that takes the balloon from the start to the goal in minimum time. In addition, the set of reachable locations on the moon or planet can be determined.

  19. Ballooning of CANDU pressure tubes. Model assessment

    International Nuclear Information System (INIS)

    The transient creep equations used to analyze the possible ballooning and failure of Zr-2.5% Nb pressure tubes during a loss-of-coolant accident (LOCA) were developed and verified using as-received Zr-2.5% Nb pressure tube material. But in a CANDU reactor, the pressure tubes absorb deuterium and are exposed to a continuous neutron fluence. Consequently, a literature survey was done to determine how irradiation damage and deuterium might affect the creep rate and ductility of Zr-2.5% Nb pressure tubes in the temperature range from 600 to 800 degrees C. It was found that irradiation damage, dissolved deuterium and deuteride blisters could possibly affect the creep rate and ductility of ZR-2.5% Nb pressure tubes in this temperature range, but deuteride platelets are expected to have little effect. Further tests are required to determine the effect of irradiation damage and deuterium on the creep rate and ductility of pressure tubes

  20. The Norwegian Sounding Rocket and Balloon Program

    Science.gov (United States)

    Skatteboe, Rolf

    2001-08-01

    The status and recent developments of the Norwegian Sounding Rocket and Balloon Program are presented with focus on national activities and recent achievements. The main part of the Norwegian program is sounding rocket launches conducted by Andøya Rocket Range from the launch facilities on Andøya and at Svalbard. For the majority of the programs, the scientific goal is investigation of processes in the middle and upper atmosphere. The in situ measurements are supplemented by a large number of ground-based support instruments located at the ALOMAR Observatory. The ongoing and planned projects are described and the highlights of the latest completed projects are given. The scientific program for the period 2001-2003 will be reviewed. Several new programs have been started to improve the services available to the international science comunity. The Hotel Payload project and MiniDusty are important examples that will be introduced in the paper. Available space related infrastructure is summarized.

  1. Intragastric balloon: ethics, medical need and cosmetics.

    Science.gov (United States)

    Kotzampassi, Katerina; Shrewsbury, Anne D

    2008-01-01

    The development of the intragastic balloon as a safe, noninvasive, alternative method to weight reduction raises all the ethical questions routinely faced by practitioners of other forms of cosmetic surgery. In the case of the morbidly, severely or merely obese, the surgeon is faced with a medical decision in a situation defined by medical parameters. The case of the overweight or normal may, however, create an ethical dilemma in which the doctor is forced to make decisions of a nonmedical nature, for which his training has not prepared him, and relating essentially to his personal attitudes and moral beliefs, culture and the recognition that 'if I don't, somebody else--possibly less competent--will'.

  2. Treatment of renovascular hypertension by transluminal angioplasty--13 years experience in a single centre

    DEFF Research Database (Denmark)

    Øvrehus, Kristian A; Andersen, Poul E; Jacobsen, Ib A

    2007-01-01

    OBJECTIVE: The study is a follow-up on treatment of renovascular hypertension (RVH) with percutaneous transluminal renal angioplasty (PTRA). METHODS: Patients were screened on the basis of clinical criteria of increased probability of RVH with renography and in selected cases with renal vein renin......: with improved control of blood pressure; group III: unchanged blood pressure control. Grouping was performed immediately after treatment, at 1 month, 6 months and at the latest follow-up. One hundred-and-twenty-two patients (124 atherosclerotic and 12 fibromuscular lesions) were treated during 13 years...... stable. CONCLUSION: PTRA is an effective treatment of RVH in patients selected by signs of a flow-restricting stenosis. Twelve percent were normotensive after angioplasty and a further 77% had better controlled hypertension. Few complications were seen and renal function was on average unchanged...

  3. Restenosis after infrapopliteal angioplasty - clinical importance, study update and further directions.

    Science.gov (United States)

    Baumann, Frederic; Diehm, Nicolas

    2013-11-01

    Patients with critical limb ischemia (CLI) represent the most severe form of peripheral arterial disease (PAD) and exhibit high mortality rates. Frequently, PAD in CLI patients involves the infrapopliteal arterial segment challenging endovascular revascularization strategies. Restenosis remains the major drawback of tibial angioplasty encountered in more than two thirds of CLI patients undergoing tibial revascularization. In contrast to earlier observations, tibial patency was recently shown to be essential to attain an optimal clinical outcome in CLI patients subsequent to tibial angioplasty. The exact pathopyhsiological mechanisms of tibial restenosis remains unclear. To date, most of our knowledge on tibial restenosis and its pathophysiology is derived from coronary arteries, based on the similarity of coronary arteries to tibial artery morphology. Nervertheless, multiple antirestenosis concepts are investigated within clinical trials to reduce tibial restenosis.Purpose of the present manuscript is to provide a current update on the pathophysiology of tibial restenosis and potential antirestenosis strategies.

  4. Spontaneous Coronary Dissection: “Live Flash” Optical Coherence Tomography Guided Angioplasty

    Science.gov (United States)

    Bento, Angela Pimenta; Fernandes, Renato Gil dos Santos Pinto; Neves, David Cintra Henriques Silva; Patrício, Lino Manuel Ribeiro; de Aguiar, José Eduardo Chambel

    2016-01-01

    Optical Coherence tomography (OCT) is a light-based imaging modality which shows tremendous potential in the setting of coronary imaging. Spontaneous coronary artery dissection (SCAD) is an infrequent cause of acute coronary syndrome (ACS). The diagnosis of SCAD is made mainly with invasive coronary angiography, although adjunctive imaging modalities such as computed tomography angiography, IVUS, and OCT may increase the diagnostic yield. The authors describe a clinical case of a young woman admitted with the diagnosis of ACS. The ACS was caused by SCAD detected in the coronary angiography and the angioplasty was guided by OCT. OCT use in the setting of SCAD has been already described and the true innovation in this case was this unique use of OCT. The guidance of angioplasty with live and short images was very useful as it allowed clearly identifying the position of the guidewires at any given moment without the use of prohibitive amounts of contrast. PMID:26989520

  5. [Comparison of the results of coronary angioplasty and stenting during one year following surgery].

    Science.gov (United States)

    Simonenko, V B; Seĭdov, V G; Zakharov, S V; Evsiukov, V V; Liubchuk, I V

    2007-01-01

    The purpose of the study was to compare long-term results of angioplasty and coronary arterial stenting (CAS) depending on the initial degree of coronary arterial (CA) lesion according to morphological stenosis classification, as well as to evaluate the influence of re-stenosis on myocardial contractility dynamics, anginal recurrence rate, and exercise tolerance. The subjects, 228 men after angioplasty and 184 men after CAS with wire stents without drug coating, were included in the study between 1989 and 2005. Coronarography was repeated in 358 patients one year after surgery. The patients were divided into two groups. The first group consisted of 161 patients, to who 180 stents were implanted. The second group consisted of 197patients, in who 226 angioplasty procedures were performed. Data were processed using standard variational statistical methods, i.e. the calculation of mean values and standard deviation. Statistical calculations were carried out using Analysis ToolPak- VBA software of Microsoft Excel 2000. The study found that one year after either intervention the number of patients without anginal symptoms fell significantly compared with this number during the in-hospital period. In group 2 the frequency of restenosis was higher and the number of patients with anginal symptoms was significantly bigger than in group 1; the number of asymptomatic patients was significantly bigger in group 1. Initial morphological characteristics of CA lesion had a significant effect on the long-term frequency of restenosis following endovascular treatment. Restenosis was 2 to 2.5 times more frequent in patients with C type CA lesion vs. patients with A type regardless the method of endovascular intervention. The results of the study demonstrate the importance of taking into account initial morphological characteristics of CA lesion; CAS is more preferable than angioplasty, especially in patients with C type CA lesion. PMID:17520881

  6. Flow diverter as a rescue therapy for a complicated basilar angioplasty.

    Science.gov (United States)

    Velioglu, Murat; Ozturk, Ersin; Sonmez, Guner; Kendirli, Tansel; Mutlu, Hakan; Basekim, Cinar

    2013-01-01

    Intracranial atherosclerotic disease is a major cause of ischemic stroke. Stenting and aggressive medical management for preventing recurrent stroke in intracranial stenosis was terminated prematurely due to a high stroke and death rate in patients randomized for intracranial stent placement. However, for some patients, angioplasty and/or stent placement remains the best approach. Flow diverters (FDs) are designed to produce a hemodynamic flow diversion by constituting a laminar flow pattern in the parent artery and are mainly used in non-ruptured complex wide-neck aneurysms as well as in ruptured aneurysms. Herein, we present a case where an FD was used in a complicated angioplasty for basilar artery atherosclerosis. A 72-year-old female patient was admitted to our hospital with left side weakness and vertigo. Her diffusion magnetic resonance imaging and magnetic resonance angiography showed right-sided pontine and left-sided occipital acute infarcts with left-sided pontine and right-sided occipital chronic infarcted areas and preocclusive mid-basilar stenosis. The patient was under supervised medical treatment. Despite chronic brain stem and occipital infarcts her modified Rankin Scale was 2. Diagnostic angiography showed no posterior communicating arteries and no pial-pial collaterals and a critical mid-basilar artery stenosis. We decided to perform intracranial angioplasty to increase the perfusion of posterior circulation and reduce the risk of additional embolic infarcts. Angioplasty was complicated with dissection and vessel perforation. We used an FD for rescue therapy to avoid rebleeding. The patient was discharged with good clinical and angiographic results.

  7. Rare occurrence of simultaneous coronary artery perforation and intracoronary thrombus formation following angioplasty

    Institute of Scientific and Technical Information of China (English)

    Su-Yan Bian; Liu-Fa Duan

    2013-01-01

    Both coronary artery perforation and intracoronary thrombus formation are life-threatening complications of percutaneous coronary interventions, which rarely occur simultaneously during angioplasty. We herein report a case of stent-related, left circumflex artery perforation, and subsequently acute left main artery thrombosis after the leakage was embolized with 7 microcoils. Intracoronary thromboectomy and systemic anticoagulant therapy were carefully used with good results. This case also represents some of our uncertainties regarding the best management of the patient.

  8. Immediate versus deferred coronary angioplasty in non-ST-segment elevation acute coronary syndromes

    OpenAIRE

    Riezebos, R.K.; Ronner, E.; Bals, ter, E.; Slagboom, T.; Smits, P.C.; Berg, ten, A.J.W.M.; Kiemeneij, F.; Amoroso, G.; Patterson, M S; Suttorp, M J; Tijssen, J.G.P.; Laarman, G.J.

    2009-01-01

    BACKGROUND: The field of acute coronary syndromes is characterised by an increasing tendency towards early invasive catheter-based diagnostics and therapeutics-a practice based on observational and retrospective data. OBJECTIVE: To compare immediate versus deferred angioplasty in patients with non-ST-segment elevation acute coronary syndromes (NSTE-ACS). METHODS: A randomised, prospective multicentre trial was performed in patients admitted with NSTE-ACS, eligible for percutaneous coronary in...

  9. Noninvasive Positive Pressure Ventilation against Reperfusion Pulmonary Edema following Percutaneous Transluminal Pulmonary Angioplasty

    OpenAIRE

    Kiyoshi Moriyama; Sayuri Sugiyama; Koji Uzawa; Mariko Kotani; Toru Satoh; Tomoko Yorozu

    2011-01-01

    A 69-year-old man with chronic thromboembolic pulmonary hypertension (CTEPH) was on amblatory oxygen inhalation therapy (3 L/min) and scheduled for percutaneous transluminal pulmonary angioplasty (PTPA). The patient's New York Heart Association functional status was class III with recent worsening of dyspnea and apparent leg edema. Transthoracic echocardiography revealed right ventricular enlargement with mean pulmonary artery pressure of 42 mmHg. After PTPA, he was complicated with postopera...

  10. Percutaneous transluminal angioplasty and stenting for severe stenosis of the intracranial extradural internal carotid artery causing transient ischemic attack or minor stroke.

    Science.gov (United States)

    Ko, Jun Kyeung; Choi, Chang Hwa; Cha, Seung Heon; Choi, Byung Kwan; Cho, Won Ho; Kang, Tae Ho; Sung, Sang Min; Cho, Han Jin; Lee, Tae Hong

    2015-08-01

    The purpose of this study is to assess the technical feasibility and clinical efficacy of percutaneous transluminal angioplasty and stenting (PTAS) for symptomatic stenosis of the intracranial extradural (petrous and cavernous) internal carotid artery (ICA).Review of medical records identified 26 consecutive patients who underwent PTAS using a balloon-expandable coronary stent (n = 15, 57.7%) or a Wingspan self-expandable stent (n = 11, 42.3%) for treatment of severe stenosis (>70%) involving the intracranial extradural ICA. The inclusion criteria were transient ischemic attack with an ABCD(2) score of ≥3 (n = 12, 46.2%) or minor stroke with an NIHSS score of ≤4 (n = 14, 53.8%). Technical success rates, complications, and angiographic and clinical outcomes were analyzed retrospectively.PTAS was technically successful in all patients. The mean stenosis ratio decreased from 77.1% to 10.0% immediately after PTAS. The overall incidence of procedural complications was 23.1%, and the postoperative permanent morbidity/mortality rate was 7.7%. A total of 22 patients were tracked over an average period of 29.9 months. During the observation period, 20 patients (90.9%) had no further cerebrovascular events and stroke recurrence occurred in two patients (9.1%), resulting in an annual stroke risk of 3.7%. Two cases (11.1%) of significant in-stent restenosis (>50%) were found on follow-up angiography (n = 18).PTAS for severe stenosis (>70%) involving the intracranial extradural ICA showed a good technical feasibility and favorable clinical outcome in patients with transient ischemic attack or minor stroke.

  11. Validation of IASI ozone profiles, using balloon sounding data

    OpenAIRE

    Delcloo, Andy; Hurtmans, Daniel; Coheur, Pierre-François; Clerbaux, Cathy

    2011-01-01

    Here we present a validation study of IASI vertical ozone profiles. This has been done using balloon ozone sonde data, which have a vertical resolution of about 100 m and measures ozone from the surface up to an altitude of about 30 km. IASI vertical ozone profiles are given as partial ozone columns [in DU per layer] between varying pressure levels. To validate the satellite derived ozone layers with the balloon ozone sounding data we integrate the ozone measured by the balloon ozone sounding...

  12. Balloon-dilatation of esophageal strictures in children

    Energy Technology Data Exchange (ETDEWEB)

    Johnsen, A.; Ingemann Jensen, L.; Mauritzen, K.

    1986-07-01

    Dilatation of benign esophageal strictures by means of a balloon-catheter is a well-established procedure in adults. This method is also useful in children. The technique is described and the results of treatment in 10 children are reported. In all our patients the stricture developed after an operation for esophageal atresia with an end-to-end anastomosis. Dilatation with a balloon-catheter seems to have the same or an even better effect than the traditional dilatation with bougies. Complications following balloon-dilatations have been few and negligible in this series and dilatations can be performed using sedation instead of general anaesthesia. Therefore, this method is recommended.

  13. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    International Nuclear Information System (INIS)

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  14. Results of the first EUSO-Balloon flight

    Science.gov (United States)

    Miyamoto, H.; Bertaina, M.; JEM-EUSO Collaboration

    2016-05-01

    EUSO-Balloon, a balloon-borne diffractive fluorescence telescope, was launched by the French Space Agency ONES from the Timmins base in Ontario (Canada) on August 25th in 2014. After reaching the floating altitude of about 38 km, EUSO-Balloon imaged the UV background for more than 5 hours before descending to ground using the key technologies of JEM-EUSO. A detailed and precise measurement of the UV background in different atmospheric and ground conditions was achieved. The instrument proved the capability of detecting Extensive Air Showers (EAS) by observing laser tracks with similar characteristics. This contribution will summarise the first results obtained concerning all the topics described above.

  15. An investigation of electrostatically deposited radionuclides on latex balloons

    Energy Technology Data Exchange (ETDEWEB)

    Price, T.; Caly, A., E-mail: Terry.Price@gmail.com [Univ. of Ontario Inst. of Technology, Oshawa, Ontario (Canada)

    2012-07-01

    Use of Canadian Nuclear Society (CNS) education material for a community science education event to promote science awareness, science culture and literacy (Science Rendezvous 2011) lead to investigation of observed phenomena. Experiments are done on balloons that are electrostatically charged then left to collect particulate. Alpha spectroscopy was performed to identify alpha emitting radioisotopes present on the balloons. The time dependent behaviour of the activity was investigated. Additionally, the Alpha activity of the balloon was compared to Beta activity. The grounds for further investigations are proposed. (author)

  16. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Pretolesi, F.; Derchi, L.E. [Dept. of Radiology, University of Genoa (Italy); Redaelli, G.; Papagni, L. [IRCCS, Ist. Auxologico Italiano, Milan (Italy)

    2001-04-01

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  17. Matrix metalloproteinase 9 level as an indicator for restenosis following cervical and intracranial angioplasty and stenting

    Directory of Open Access Journals (Sweden)

    Jun-peng Liu

    2015-01-01

    Full Text Available Cervical and intracranial angioplasty and stenting is an effective and safe method of reducing the risk of ischemic stroke, but it may be affected by in-stent restenosis. The present study investigated serum level of matrix metalloproteinase 9 as a predictor of restenosis after 40 patients underwent cervical and/or intracranial angioplasty and stenting. Results showed that restenosis occurred in 30% (3/10 of patients when the serum level of matrix metalloproteinase 9 at 3 days after surgery was 2.5 times higher than preoperative level. No restenosis occurred when the serum level of matrix metalloproteinase 9 at 3 days after surgery was not 2.5 times higher than preoperative level. Restenosis occurred in 12% (2/17 of patients when the serum level of matrix metalloproteinase 9 was higher than preoperative level for more than 30 days after surgery, but only occurred in 4% (1/23 of patients when the serum level of matrix metalloproteinase 9 was higher than preoperative level for less than 30 days after surgery. However, the differences observed were not statistically significant (P > 0.05. Experimental findings indicate that when the serum level of matrix metalloproteinase 9 is 2.5 times higher than preoperative level at 3 days after cervical and intracranial angioplasty and stenting, it may serve as a predictor of in-stent restenosis.

  18. +Ophitoxaemia and myocardial infarction--the issues during primary angioplasty: a review.

    Science.gov (United States)

    Gupta, Prabha Nini; Thomas, Jinesh; Francis, Preetham Kumar; Shylaja, Sajith Vamadevan

    2014-10-23

    'The Big four' are the most poisonous snakes in India, and especially in Kerala. These include the cobra, the viper, the krait and the sea snake. Most of the poisonous snakebites in India occur in Kerala. We believe there are only a few reports of myocardial infarction after snakebites and most of these are viper bites. We believe this is the second case of primary angioplasty for a snakebite. There are at least a few potential issues in performing a primary angioplasty in a snakebite case, namely (1) Is it a thrombus or a spasm? (2) Are the bleeding parameters deranged? Will the patient tolerate tirofiban and other glycoprotein (GB) 2b3a inhibitors? Will he develop dangerous bleeding due to the high dose of heparin needed? Further, would we save the patient from myocardial infarction only to lose him to renal failure, both due to the nephrotoxicity of the venom, the kidney being further damaged by the contrast media used for the angioplasty? We discuss all these issues as they crossed our mind, and hope it will help further treatment in others. We would like to review the available literature on these points and describe a recent case of ours.

  19. Vibrational angioplasty in recanalization of chronic femoropopliteal arterial occlusions: Single center experience

    Energy Technology Data Exchange (ETDEWEB)

    Kapralos, Ioannis, E-mail: jkapgr@yahoo.gr [251 Hellenic Air Force General Hospital, Athens (Greece); Kehagias, Elias, E-mail: eliaskmd@yahoo.gr [Interventional Radiology Unit, Department of Radiology, Faculty of Medicine, University of Crete, Heraklion, Crete (Greece); Ioannou, Christos, E-mail: ioannou@med.uoc.g [Faculty of Medicine, University of Crete, Heraklion, Crete (Greece); Bouloukaki, Izolde, E-mail: izolthi@gmail.com [Interventional Radiology Unit, Department of Radiology, Faculty of Medicine, University of Crete, Heraklion, Crete (Greece); Kostas, Theodoros, E-mail: kostasth@mailbox.gr [Faculty of Medicine, University of Crete, Heraklion, Crete (Greece); Katsamouris, Asterios, E-mail: asterios@med.uoc.gr [Faculty of Medicine, University of Crete, Heraklion, Crete (Greece); Tsetis, Dimitrios, E-mail: tsetis@med.uoc.gr [Interventional Radiology Unit, Department of Radiology, Faculty of Medicine, University of Crete, Heraklion, Crete (Greece)

    2014-01-15

    Purpose: This prospective study aims to present the overall success rate, safety and long-term outcome of vibrational angioplasty technique, in the treatment of chronic total femoropopliteal occlusions in our institute. Methods: Between October 2000 and December 2008, patients with chronic total femoropoliteal arterial occlusions, treated with vibrational angioplasty during the same session after a failed attempt with conventional recanalization technique, were included. Patient's follow up included serial ankle-brachial index measurements and arterial duplex ultrasound examinations at 1, 3, 6, 12, 24, 36 and 48 months. Results: Twenty-seven patients (16 males and 11 females) and twenty-eight lesions were included in our study. Twenty-five lesions (89.3%) were successfully recanalized. Pain relief was noticed in twenty-one cases. From ten lesions with tissue loss (ulcer or gangrene) in successfully recanalized occlusions, six healed without major, or minor amputation. One non-healing amputation stump was healed after recanalization, without further complications. Four limbs underwent amputation (one minor and three major) despite successful recanalization, however all had an excellent healing of the amputation stump without further complications. The Kaplan–Meier test demonstrated 90%, 85% and 70% amputation-free survival rate at 12, 24 and 36 months, respectively. No major or minor complications were encountered. Conclusions: Vibrational angioplasty is a safe, effective and durable endovascular technique for the treatment of chronic total occlusions in patients with limb ischemia that would be difficult to recanalize using conventional intraluminal techniques.

  20. Matrix metalloproteinase 9 level as an indicator for restenosis following cervical and intracranial angioplasty and stenting

    Institute of Scientific and Technical Information of China (English)

    Jun-peng Liu; Yin-zhou Wang; Yong-kun Li; Qiong Cheng; Zheng Zheng

    2015-01-01

    Cervical and intracranial angioplasty and stenting is an effective and safe method of reducing the risk of ischemic stroke, but it may be affected by in-stent restenosis. The present study in-vestigated serum level of matrix metalloproteinase 9 as a predictor of restenosis after 40 patients underwent cervical and/or intracranial angioplasty and stenting. Results showed that resteno-sis occurred in 30% (3/10) of patients when the serum level of matrix metalloproteinase 9 at 3 days after surgery was 2.5 times higher than preoperative level. No restenosis occurred when the serum level of matrix metalloproteinase 9 at 3 days after surgery was not 2.5 times higher than preoperative level. Restenosis occurred in 12% (2/17) of patients when the serum level of matrix metalloproteinase 9 was higher than preoperative level for more than 30 days after surgery, but only occurred in 4% (1/23) of patients when the serum level of matrix metalloproteinase 9 was higher than preoperative level for less than 30 days after surgery. However, the differences observed were not statistically signiifcant (P > 0.05). Experimental ifndings indicate that when the serum level of matrix metalloproteinase 9 is 2.5 times higher than preoperative level at 3 days after cervi-cal and intracranial angioplasty and stenting, it may serve as a predictor of in-stent restenosis.

  1. Percutaneous trans-ulnar artery approach for coronary angiography and angioplasty; A case series study

    Science.gov (United States)

    Roghani-Dehkordi, Farshad; Hadizadeh, Mahmood; Hadizadeh, Fatemeh

    2015-01-01

    BACKGROUND Coronary angiography is the gold standard method for diagnosis of coronary heart disease and usually performed by femoral approach that has several complications. To reduce these complications, upper extremity approach is increasingly used and is becoming preferred access site by many interventionists. Although radial approach is relatively well studied, safety, feasibility and risk of applying ulnar approach in not clearly known yet. METHODS We followed 97 patients (man = 56%, mean ± standard deviation of age = 57 ± 18) who had undergone coronary angiography or angioplasty via ulnar approach for 6-10 months and recorded their outcomes. RESULTS In 97 patients out of 105 ones (92.38%), procedure through ulnar access were successfully done. Unsuccessful puncture (3 patients), wiring (2 patients), passing of sheet (2 patients), and anatomically unsuitable ulnar artery (1 patient) were the reasons of failure. In 94 patients (89.52%), the angiography and angioplasty was done without any complications. Five patients (5.1%) hematoma and 11 patients (11%) experienced low-grade pain that resolved with painkiller. No infection, amputation or need for surgery was reported. CONCLUSION This study demonstrated that ulnar access in our patients was a safe and practical approach for coronary angiography or angioplasty, without any major complication. Bearing in mind its high success rate, it can be utilized when a radial artery is not useful for the catheterization and in cases such as prior harvesting of the radial artery (in prior coronary artery bypass grafting). PMID:26715936

  2. Assessment of "silent" restenosis and long-term follow-up after successful angioplasty in single vessel coronary artery disease: the value of quantitative exercise electrocardiography and quantitative coronary angiography

    NARCIS (Netherlands)

    G-J. Laarman (GertJan); H.E. Luijten; L.G.P.M. van Zeyl; K.J. Beatt (Kevin); J.G.P. Tijssen (Jan); P.W.J.C. Serruys (Patrick); P.J. de Feyter (Pim)

    1990-01-01

    textabstractExercise electrocardiographic (ECG) testing during follow-up after coronary angioplasty is widely applied to evaluate the efficacy of angioplasty, even in asymptomatic patients. One hundred forty-one asymptomatic patients without previous myocardial infarction underwent quantitative exer

  3. Long-term results after primary infrapopliteal angioplasty for limb ischemia; Langzeitergebnisse nach Ballonangioplastie kruraler Arterien

    Energy Technology Data Exchange (ETDEWEB)

    Alfke, H. [Klinikum Luedenscheid (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Marburg Univ. (Germany). Klinik fuer Strahlendiagnostik; Vannucchi, A. [Marburg Univ. (Germany). Klinik fuer Strahlendiagnostik; Froelich, J.J. [Marburg Univ. (Germany). Klinik fuer Strahlendiagnostik; Klinikum Bad Hersfeld (Germany). Klinik fuer Radiologie und Nuklearmedizin; El-Sheik, M.; Wagner, H.J. [Marburg Univ. (Germany). Klinik fuer Strahlendiagnostik; Vivantes-Klinikum im Friedrichshain (Germany). Inst. fuer Radiologie und Interventionelle Therapie

    2007-08-15

    Purpose: To evaluate the technical success rate, procedure-related complications, and clinical long-term results for patients who underwent infrapopliteal angioplasty. Materials and Methods: We retrospectively evaluated all patients who underwent infrapopliteal angioplasty to treat critical chronic limb ischemia or severe claudication from 1/1997 to 12/1999. We excluded patients with acute (< 2 weeks) limb ischemia. Procedure-related data were prospectively documented in a database and analyzed with a focus on the technical success rate and procedure-related complications. In addition all clinical documents were analyzed, and a follow-up examination was performed or telephone interviews were conducted with patients, relatives and referring doctors for follow-up. The primary end points were the limb salvage rate and patient survival rate. The secondary end points included the complication rate, technical success rate, and walking distance. Results: 112 patients with a mean age of 72 years (41 women, 71 men) underwent crural angioplasty on 121 limbs. Four patients suffered from severe claudication (Rutherford category 3) and all others had critical chronic limb ischemia (category 4 to 6). The complication rate was 2.7 %. The technical success rate was 92 %. The ankle brachial index increased from 0.59 to 0.88. The mean walking distance increased significantly from 52 {+-} 66 to 284 {+-} 346 meters at the time of follow-up. The limb salvage rate was 83.6 % after one year and 81.1 % after three years. The mean survival rate according to Kaplan-Meier was 79.4 %, 69.2 %, and 54.2 % at 1, 2, and 3 years, respectively. Patients with at least one patent run-off vessel after angioplasty had a significantly better limb salvage rate. Diabetes was not a risk factor for limb salvage. Conclusion: Infrapopliteal angioplasty shows a high technical success rate with an acceptable complication rate. The clinical long-term success seems favorable if a least one open run-off vessel was

  4. CLIMB: cosmic light isotopes and muons with balloons

    Energy Technology Data Exchange (ETDEWEB)

    Pearce, M. E-mail: pearce@particle.kth.se; Adriani, O.; Boezio, M.; Bonvicini, V.; Carlson, P.; Mocchiutti, E.; Papini, P.; Straulino, S.; Vacchi, A.; Vannuccini, E.; Zampa, G.; Zampa, N

    2004-06-01

    A new balloon-borne experiment is proposed which will measure high-energy light isotopes at the top of the Earth's atmosphere and cosmic ray muons at fixed altitudes within the Earth's atmosphere.

  5. Design Evolution and Methodology for Pumpkin Super-Pressure Balloons

    Science.gov (United States)

    Farley, Rodger

    The NASA Ultra Long Duration Balloon (ULDB) program has had many technical development issues discovered and solved along its road to success as a new vehicle. It has the promise of being a sub-satellite, a means to launch up to 2700 kg to 33.5 km altitude for 100 days from a comfortable mid-latitude launch point. Current high-lift long duration ballooning is accomplished out of Antarctica with zero-pressure balloons, which cannot cope with the rigors of diurnal cycles. The ULDB design is still evolving, the product of intense analytical effort, scaled testing, improved manufacturing, and engineering intuition. The past technical problems, in particular the s-cleft deformation, their solutions, future challenges, and the methodology of pumpkin balloon design will generally be described.

  6. Current status of intragastric balloon for obesity treatment

    Science.gov (United States)

    Kim, Seung Han; Chun, Hoon Jai; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Jeen, Yoon Tae

    2016-01-01

    Endoscopic bariatric therapy may be a useful alternative to pharmacological treatment for obesity, and it provides greater efficacy with lower risks than do conventional surgical procedures. Among the various endoscopic treatments for obesity, the intragastric balloon is associated with significant efficacy in body weight reduction and relief of comorbid disease symptoms. Anatomically, this treatment is based on gastric space-occupying effects that increase the feeling of satiety and may also affect gut neuroendocrine signaling. The simplicity of the intragastric balloon procedure may account for its widespread role in obesity treatment and its applicability to various degrees of obesity. However, advances in device properties and procedural techniques are still needed in order to improve its safety and cost-effectiveness. Furthermore, verification of the physiological outcomes of intragastric balloon treatment and the clinical predictive factors for treatment responses should be considered. In this article, we discuss the types, efficacy, safety, and future directions of intragastric balloon treatment. PMID:27350727

  7. 10 meter Sub-Orbital Large Balloon Reflector (LBR) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Besides serving as a launch vehicle, the carrier balloon provides a stable mount for the enclosed telescope. Looking up, the LBR will serve as a telescope. Looking...

  8. Proposed techniques for launching instrumented balloons into tornadoes

    Science.gov (United States)

    Grant, F. C.

    1971-01-01

    A method is proposed to introduce instrumented balloons into tornadoes by means of the radial pressure gradient, which supplies a buoyancy force driving to the center. Presented are analytical expressions, verified by computer calculations, which show the possibility of introducing instrumented balloons into tornadoes at or below the cloud base. The times required to reach the center are small enough that a large fraction of tornadoes are suitable for the technique. An experimental procedure is outlined in which a research airplane puts an instrumented, self-inflating balloon on the track ahead of the tornado. The uninflated balloon waits until the tornado closes to, typically, 750 meters; then it quickly inflates and spirals up and into the core, taking roughly 3 minutes. Since the drive to the center is automatically produced by the radial pressure gradient, a proper launch radius is the only guidance requirement.

  9. Low Cost Variable Conductance Heat Pipe for Balloon Payload Project

    Data.gov (United States)

    National Aeronautics and Space Administration — While continuously increasing in complexity, the payloads of terrestrial high altitude balloons need a thermal management system to reject their waste heat and to...

  10. Isothermal pumping analysis for high-altitude tethered balloons

    OpenAIRE

    Kuo, Kirsty A.; Hunt, Hugh E.M.

    2015-01-01

    High-altitude tethered balloons have potential applications in communications, surveillance, meteorological observations and climate engineering. To maintain balloon buoyancy, power fuel cells and perturb atmospheric conditions, fluids could be pumped from ground level to altitude using the tether as a hose. This paper examines the pumping requirements of such a delivery system. Cases considered include delivery of hydrogen, sulfur dioxide (SO2) and powders as fluid-based slurries. Isothermal...

  11. Small Research Balloons in a Physics Course for Education Majors

    Science.gov (United States)

    Bruhweiler, F. C.; Verner, E.; Long, T.; Montanaro, E.

    2013-12-01

    At The Catholic Univ. of America, we teach an experimental physics course entitled Physics 240: The Sun-Earth Connection, which is designed for the undergraduate education major. The emphasis is on providing hands-on experience and giving the students an exciting experience in physics. As part of this course, in the Spring 2013 semester, we instituted a project to plan, build, launch, and retrieve a small (~1.3 kg) research balloon payload. The payload flown was a small GPS unit that sent its position to an Internet site, a small wide-angle high-resolution video camera, and an analog refrigerator thermometer placed in the field of view of the camera. All data were stored on the camera sim-card. Students faced the problems of flying a small research balloon in the congested, densely populated Northeast Corridor of the US. They used computer simulators available on the Web to predict the balloon path and flight duration given velocities for the Jet Stream and ground winds, as well as payload mass and amount of helium in the balloon. The first flight was extremely successful. The balloon was launched 140 km NW of Washington DC near Hagerstown, MD and touched down 10 miles (16 km) NW of York, PA, within 1.6 km of what was predicted. The balloon reached 73,000 ft (22,000 m) and the thermometer indicated temperatures as low as -70 degrees Fahrenheit (-57 C) during the flight. Further balloon flights are planned in conjunction with this course. Additional exercises and experiments will be developed centered around these flights. Besides learning that science can be exciting, students also learn that science is not always easily predictable, and that these balloon flights give an understanding of many of problems that go into real scientific space missions. This project is supported in part by an educational supplement to NASA grant NNX10AC56G

  12. The Hubble party balloon and the expanding universe

    Science.gov (United States)

    Zendri, G.; Rosi, T.; Oss, S.

    2016-09-01

    We show that the metaphor of the inflated balloon used to describe expanding space-time according to the Hubble law can be transformed into a simple laboratory experiment. We obtain, in terms of measured recession speeds and distances of ink dots drawn on a party balloon, easy renditions of various cosmological models, such as the static one and the Einstein-De Sitter universe.

  13. Development of a tiny tandem balloon system for atmospheric observation

    Science.gov (United States)

    Saito, Yoshitaka; Yamada, Kazuhiko; Fujiwara, Masatomo

    2016-07-01

    A tandem balloon system with a combination of a zero-pressure balloon on top and a super-pressure balloon on the bottom has a unique trajectory characteristic, with different flight altitudes between day and night and thus with ascending and descending motions at dawn and dusk, respectively. This characteristic provides a unique opportunity to explore the atmosphere, e.g., the upper tropospheric and lower stratospheric region with cross-tropopause measurements twice a day. We started development of a tiny tandem balloon system using a 10 m^{3} super-pressure balloon and a 100 m^{3} zero-pressure balloon, with a capability of carrying 3 kg of payload. One of the scientific targets is to measure water vapor, cloud particles, and temperature around the tropical tropopause which is the entry point of the stratospheric and mesospheric meridional circulation. For the data transfer, the iridium satellite communication module, SBD9603 is used. In this paper, the current status of the development will be reported.

  14. Burn Injury Arise From Flying Balloon Toys

    Directory of Open Access Journals (Sweden)

    Yalcin Kulahci

    2007-08-01

    Full Text Available Many of peoples are faced minor or major burn injuries in their life. Even the most widespread burn cause is flame injuries, too different burn cause pointed out in literature like Acetylen burns. The cases which imply in literature, mostly causes from explosion of high pressure acetylene tube, metal oxygene patch flame or carbide lamp using from cave explorers. An interesting acetylene burn cause in Turkey was publised by the authors. This cases was to come into being from flying toy balloons flame. 80 person was injured from flying toy ballons flame in a meeting in 2002. Although this potential risks of acetylene, helium have not any of some risk. But helium was provided from other countries and have more price. The injuries which caused from acetylene burns like 1st -2nd degree burns. Consequently that was known helium is more avaliable for using in toy sector, and never cause burn injuries like this. [TAF Prev Med Bull. 2007; 6(4: 291-296

  15. Burn Injury Arise From Flying Balloon Toys

    Directory of Open Access Journals (Sweden)

    Yalcin Kulahci

    2007-08-01

    Full Text Available Many of peoples are faced minor or major burn injuries in their life. Even the most widespread burn cause is flame injuries, too different burn cause pointed out in literature like Acetylen burns. The cases which imply in literature, mostly causes from explosion of high pressure acetylene tube, metal oxygene patch flame or carbide lamp using from cave explorers. An interesting acetylene burn cause in Turkey was publised by the authors. This cases was to come into being from flying toy balloons flame. 80 person was injured from flying toy ballons flame in a meeting in 2002. Although this potential risks of acetylene, helium have not any of some risk. But helium was provided from other countries and have more price. The injuries which caused from acetylene burns like 1st -2nd degree burns. Consequently that was known helium is more avaliable for using in toy sector, and never cause burn injuries like this. [TAF Prev Med Bull 2007; 6(4.000: 291-296

  16. Alpha particle effects on MHD ballooning

    International Nuclear Information System (INIS)

    During the period, as the first step towards the goal of detail understanding of the effects of alpha particle on MHD Ballooning Modes, a new numerical approach to investigate the stability of low-frequency fluctuations in high temperature tokamaks was developed by solving the gyrokinetic equations for the ion and electron directly as an initial value problem. The advantage of this approach is the inclusion of many important kinetic features of the problem without approximations and computationally more economical than particle-pushing simulation. The ion-temperature-gradient-mode was investigated to benchmark this new simulation technique. Previous results in literature were recovered. Both the adiabatic electron model and the full drift-kinetic electron model are studied. Numerical result shows that the full drift-kinetic electron model is more unstable. The development of subcycling technique to handle the fast electron bounce time is particularly significant to apply this new approach to the alpha particle problem since alpha particle bounce frequency is also significantly higher than the mode frequency. This new numerical technique will be the basis of future study of the microstability in high temperature tokamaks with alpha particles (or any energetic species). 15 refs., 13 figs

  17. Acute cell death rate of vascular smooth muscle cells during or after short heating up to 20s ranging 50 to 60°C as a basic study of thermal angioplasty

    Science.gov (United States)

    Shinozuka, Machiko; Shimazaki, Natsumi; Ogawa, Emiyu; Machida, Naoki; Arai, Tsunenori

    2014-02-01

    We studied the relations between the time history of smooth muscle cells (SMCs) death rate and heating condition in vitro to clarify cell death mechanism in heating angioplasty, in particular under the condition in which intimal hyperplasia growth had been prevented in vivo swine experiment. A flow heating system on the microscope stage was used for the SMCs death rate measurement during or after the heating. The cells were loaded step-heating by heated flow using a heater equipped in a Photo-thermo dynamic balloon. The heating temperature was set to 37, 50-60°C. The SMCs death rate was calculated by a division of PI stained cell number by Hoechst33342 stained cell number. The SMCs death rate increased 5-10% linearly during 20 s with the heating. The SMCs death rate increased with duration up to 15 min after 5 s heating. Because fragmented nuclei were observed from approximately 5 min after the heating, we defined that acute necrosis and late necrosis were corresponded to within 5 min after the heating and over 5 min after the heating, respectively. This late necrosis is probably corresponding to apoptosis. The ratio of necrotic interaction divided the acute necrosis rate by the late necrosis was calculated based on this consideration as 1.3 under the particular condition in which intimal hyperplasia growth was prevented in vivo previous porcine experiment. We think that necrotic interaction rate is larger than expected rate to obtain intimal hyperplasia suppression.

  18. Too much coronary angioplasty in the USA?: less may be better - the conflicting roles of inexactness of medicine as a science, asymmetric information, technologic imperative, unnecessary care and ethicomedicinomics in US healthcare.

    Science.gov (United States)

    Onuigbo, M A C; Agbasi, N

    2014-09-01

    US healthcare expenditure per capita far exceeds that of any other nation in the world. Indeed, over the last 15 years, the USA has distantly surpassed most countries in the developed world in total healthcare expenditures per capita with the USA now spending 17.4% of its gross domestic product (GDP) on healthcare ($7960 per capita), compared with only 8.5% of GDP in Japan ($2878 per capita), a distant second. Consequently, by current projections, the US healthcare bill will have ballooned from $2.5 trillion in 2009 to over $4.6 trillion by 2020. Such spending growth rates are unsustainable and the system would soon go broke if not corrected. The drivers of these spending growth rates in US healthcare are several and varied. Indeed, in September 2012, the Institute of Medicine reported that US healthcare squandered $750 billion in 2009 through unneeded care, Byzantine paperwork, fraud and other wasteful activities. Recently, the question was raised as to whether we have too much coronary angioplasty in the USA. In this analysis, we examine these and other various related aspects of US healthcare, make comparisons with other national healthcare delivery systems, and suggest several reengineering modalities to help fix these compellingly glaring glitches and maladies of US healthcare.

  19. Development of a super-pressure balloon with a diamond-shaped net --- result of a ground inflation test of a 2,000 cubic-meter balloon ---

    Science.gov (United States)

    Saito, Yoshitaka; Nakashino, Kyoichi; Akita, Daisuke; Matsushima, Kiyoho; Shimadu, Shigeyuki; Goto, Ken; Hashimoto, Hiroyuki; Matsuo, Takuma

    2016-07-01

    A light super-pressure balloon has been developed using a method to cover a balloon with a diamond-shaped net of high-tensile fibers. The goal is to fly a payload of 900 kg to the altitude of 37 km with a 300,000 m^{3} balloon. Beginning from a demonstration test of the net-balloon with a 10 m^{3} balloon in 2010, we have been polished the net-balloon through ground inflation tests and flight tests, including a flight test of a 3,000 m ^{3} balloon in the tandem balloon configuration with a 15,000 m^{3} zero-pressure balloon in 2012, and a flight test of a 10 m^{3} balloon in the tandem balloon configuration with a 2 kg rubber balloon in 2013, as reported in the last COSPAR. In 2014, we developed a 5,000 m^{3} balloon and performed a ground inflation test to find that the balloon burst from a lip panel for termination with a differential pressure of 425 Pa. It was due to a stress concentration at the edge of a thick tape attached along the termination mechanism. In 2015, we modified the balloon by adding tapes on the lip panel to avoid the stress concentration, and also shorten the net length to leave some margin of the film and performed a ground inflation test again to find the balloon showed asymmetrical deployment and burst from the edge of the net with a differential pressure of 348 Pa. We consider it is due to the margin of the film along the circumferential direction, and proposed a gore shape which circumference length is kept as determined by the pumpkin shape of the balloon but setting meridian length longer than that. We developed a 10 m^{3} balloon with the gore design to find that the balloon deployed symmetrically and showed the burst pressure of 10,000 Pa. In 2016, we are going to develop a 2,000 m^{3} balloon with the gore design and perform its ground inflation test. In this paper, we are going to report its result with the sequence of the development.

  20. Treatment of hemodialysis vascular access rupture irresponsive to prolonged balloon tamponade: Retrospective evaluation of the effectiveness of N-butyl cyanoacrylate seal-off technique

    Energy Technology Data Exchange (ETDEWEB)

    Weng, Mei Jul; Liang, Huei Lung; Pan, Huay Ben [Dept. of Radiology, Kaohsiung Veterans General Hospital, Kaohsiung (China); Chen, Matt Chiung Yu [Dept. of Radiology, Yuan' s General Hospital, Kaohsiung (China)

    2013-01-15

    The current study retrospectively evaluated whether the percutaneous N-butyl cyanoacrylate (NBCA) seal-off technique is an effective treatment for controlling the angioplasty-related ruptures, which are irresponsive to prolonged balloon tamponade, during interventions for failed or failing hemodialysis vascular accesses. We reviewed 1588 interventions performed during a 2-year period for dysfunction and/or failed hemodialysis vascular access sites in 1569 patients. For the angioplasty-related ruptures, which could not be controlled with repeated prolonged balloon tamponade, the rupture sites were sealed off with an injection of a glue mixture (NBCA and lipiodol), via a needle/needle sheath to the rupture site, under a sonographic guidance. Technical success rate, complications and clinical success rate were reported. The post-seal-off primary and secondary functional patency rates were calculated by a survival analysis with the Kaplan-Meier method. Twenty ruptures irresponsive to prolonged balloon tamponade occurred in 1588 interventions (1.3%). Two technical failures were noted; one was salvaged with a bailout stent-graft insertion and the other was lost after access embolization. Eighteen accesses (90.0%) were salvaged with the seal-off technique; of them, 16 ruptures were completely sealed off, and two lesions were controlled as acute pseudoaneurysms. Acute pseudoaneurysms were corrected with stentgraft insertion in one patient, and access ligation in the other. The most significant complication during the follow-up was delayed pseudoaneurysm, which occurred in 43.8% (7 of 16) of the completely sealed off accesses. Delayed pseudoaneurysms were treated with surgical revision (n = 2), access ligation (n = 2) and observation (n = 3). During the follow-up, despite the presence of pseudoaneurysms (acute = 1, delayed = 7), a high clinical success rate of 94.4% (17 of 18) was achieved, and they were utilized for hemodialysis at the mean of 411.0 days. The post

  1. [Correction of dyslipidemia in patients with arteriosclerosis obliterans as a method for improving the results of endovascular angioplasty].

    Science.gov (United States)

    Petukhov, V A; Seitmykhamedov, M D; Dibirov, A D; Dubovik, S G; Sergeeva, N A; Prokubovskiĭ, V I

    1992-01-01

    The authors analyse the results of endovascular angioplasty of the pelvic and lower limb arteries in 147 patients of various age suffering from arteriosclerosis obliterans. It was found that the results of endovascular angioplasty depended on the state of the lipid balance. The necessity for correcting the shifts in the lipid metabolism is shown. The article evaluates the results of dyslipidemia correction by dietotherapy, pharmacotherapy, and operation for partial ilio-shunting in patients with arteriosclerosis obliterans of the pelvic and lower limb arteries. The efficacy of the listed methods of treatment are analysed according to the severity of dyslipidemia. PMID:1457133

  2. Time course, predictors and clinical implications of stent thrombosis following primary angioplasty. Insights from the DESERT cooperation

    DEFF Research Database (Denmark)

    De Luca, Giuseppe; Dirksen, Maurits T; Spaulding, Christian;

    2013-01-01

    on the timing of stent thrombosis (ST) with both DES and bare metal stents (BMS) and its prognostic significance in patients undergoing pPCI. The Drug-Eluting Stent in Primary Angioplasty (DESERT) cooperation is based on a pooled database including individual data of randomised trials that evaluate the long...... angioplasty with BMS or DES. At 1201 ± 440 days, ST occurred in 267 patients (4.25%). Most of the events were acute or subacute (within 30 days) and very late (> 1 years), with different distribution between DES vs BMS. Patients with ST were more often diabetic (21.7% vs 15.1%, p=0.005), more frequently had...

  3. Contribution of inhibitory receptor glycoprotein iib / iiia in coronary angioplasty and acute coronary syndrome, about 152 patients

    International Nuclear Information System (INIS)

    The aim of our study was to evaluate the immediate results and long-term intake of anti-GP IIb / IIIa inhibitors for patients with acute coronary syndrome treated with coronary angioplasty. The use of anti-GP IIb / IIIa is a valid therapeutic option in patients with acute coronary syndrome with signs of severity and for patients undergoing complex angioplasty. Adverse effects of anti-GP IIb / IIIa can be seen to encourage vigilance and careful monitoring during the administration of these molecules and perfect knowledge of their pharmacological properties for appropriate use.

  4. Determination of membrane tension during balloon distension of intestine.

    Science.gov (United States)

    Gregersen, H; Kassab, G S; Fung, Y C

    2004-09-01

    During the last decades, it has become increasingly common to make balloons distension in visceral organs in vivo. In particular this is true for studies of gastrointestinal motor function and biomechanics. Balloon distension is often used for assessment of small intestinal compliance and tension based on Laplace's law for cylindrical pressure pipes. This commonly used law is valid only when the balloon-distended intestine is cylindrical. Experimentally, it is seen that the diameter of the balloon-distended intestine is not a constant, but variable in the axial direction. Hence, it is necessary to improve Laplace's law for intestinal investigation. In this paper we develop the framework for determination of the tension distribution in circumferential and longitudinal direction during balloon distension. When the radii of curvature are measured from a photograph of the intestinal profile, then the membrane stress resultants can be computed everywhere in the intestine in contact with the balloon from the equations of equilibrium. The experimental data were obtained from small intestinal segments from five pigs and three guinea pigs. Papaverine was injected before the animals were sacrificed to relax the intestinal smooth muscle. The segments were immersed in a bath with calcium-free Krebs solution with dextran and EGTA. A balloon was distended in the lumen with pressures up to 15 cmH2O in the pigs and 10 cmH2O in the guinea pigs and radii were measured along the z-axis. The tension in circumferential direction had its maximum approximately 25% away from the middle of the balloon. The circumferential tension was 2-3 times higher than the longitudinal tension. In conclusion when we know the shape of the intestine, we can compute the circumferential and longitudinal components of tension. The large variation in tensions along the z axis must be considered when performing balloon distension studies in the gastrointestinal tract for studying physiological and

  5. The History of Primary Angioplasty and Stenting for Acute Myocardial Infarction.

    Science.gov (United States)

    Smilowitz, Nathaniel R; Feit, Frederick

    2016-01-01

    The evolution of the management of acute myocardial infarction (MI) has been one of the crowning achievements of modern medicine. At the turn of the twentieth century, MI was an often-fatal condition. Prolonged bed rest served as the principal treatment modality. Over the past century, insights into the pathophysiology of MI revolutionized approaches to management, with the sequential use of surgical coronary artery revascularization, thrombolytic therapy, and percutaneous coronary intervention (PCI) with primary coronary angioplasty, and placement of intracoronary stents. The benefits of prompt revascularization inspired systems of care to provide rapid access to PCI. This review provides a historical context for our current approach to primary PCI for acute MI.

  6. Study of Traditional Chinese Medicine in Intervening Vascular Remodeling after Percutaneous Transluminal Coronary Angioplasty

    Institute of Scientific and Technical Information of China (English)

    鹿小燕; 徐浩; 史大卓; 陈可冀

    2004-01-01

    Interventional therapy of coronary heart disease (CHD) includes percutaneous transluminal coronary angioplasty (PTCA), stent implantation etc. Owing to its revascularization without cardiac surgery, it has been the main effective method in treating CHD. But at the same time, there exists the problem of restenosis (RS). After PTCA, RS rate can reach 30% to 50%, even with directstenting into the vessels, it still reaches 20% to 35%. So this affects long-term effect of interventional therapy, which directly relates to prognosis of patients with CHD and has been a hot spot of study in the field of preventing and treating CHD.

  7. Study of Traditional Chinese Medicine in Intervening Vascular Remodeling after Percutaneous Transluminal Coronary Angioplasty

    Institute of Scientific and Technical Information of China (English)

    鹿小燕; 徐浩; 史大卓; 陈可冀

    2004-01-01

    Interventional therapy of coronary heart disease (CHD) includes percutaneous transluminal coronary angioplasty (PTCA), stent implantation etc. Owing to its revascularization without cardiac surgery, it has been the main effective method in treating CHD. But at the same time, there exists the problem of restenosis (RS). After PTCA, RS rate can reach 30% to 50%, even with direct stenting into the vessels, it still reaches 20% to 35%. So this affects long-term effect of interventional therapy, which directly relates to prognosis of patients with CHD and has been a hot spot of study in the field of preventing and treating CHD.

  8. Impotence due to external Iliac steal syndrome: Treatment with percutaneous transluminal angioplasty and stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Gur, Serkan [Sifa University, Dept. of Radiology, Izmir (Turkmenistan); Oguzkurt, Levent; Kaya, Bilal; Tekbas, Guven; Ozkan, Ugur [Baskent University, Faculty of Medicine, Dept. of Radiology, Adana (Turkmenistan)

    2013-01-15

    We report a case of erectile dysfunction caused by external iliac artery occlusion, associated with pelvic steal syndrome; bilateral internal iliac arteries were patent. The patient stated that he had experienced erectile dysfunction at similar times along with claudication, but he did not mention it before angiography. He expressed that the erectile dysfunction did not last long and that he felt completely okay after the interventional procedure, in addition to his claudication. Successful treatment of the occlusion, by percutaneous transluminal angioplasty and stent implantation, helped resolve erectile dysfunction completely and treat the steal syndrome.

  9. Complexity Analysis of Balloon Drawing for Rooted Trees

    CERN Document Server

    Lin, Chun-Cheng; Poon, Sheung-Hung; Fan, Jia-Hao

    2010-01-01

    In a balloon drawing of a tree, all the children under the same parent are placed on the circumference of the circle centered at their parent, and the radius of the circle centered at each node along any path from the root reflects the number of descendants associated with the node. Among various styles of tree drawings reported in the literature, the balloon drawing enjoys a desirable feature of displaying tree structures in a rather balanced fashion. For each internal node in a balloon drawing, the ray from the node to each of its children divides the wedge accommodating the subtree rooted at the child into two sub-wedges. Depending on whether the two sub-wedge angles are required to be identical or not, a balloon drawing can further be divided into two types: even sub-wedge and uneven sub-wedge types. In the most general case, for any internal node in the tree there are two dimensions of freedom that affect the quality of a balloon drawing: (1) altering the order in which the children of the node appear in...

  10. Time-dependent strains and stresses in a pumpkin balloon

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    This paper presents a study of pumpkin-shaped superpressure balloons consisting of gores made from a thin polymeric film attached to high stiffness meridional tendons This type of design is being used for the NASA ULDB balloons The gore film shows considerable time-dependent stress relaxation whereas the behaviour of the tendons is essentially time-independent Upon inflation and pressurization the instantaneous i e linear-elastic strain and stress distributions in the film show significantly higher values in the meridional direction However over time and due to the biaxial visco-elastic stress relaxation of the the gore material the em hoop strains increase and the em meridional stresses decrease whereas the em remaining strain and stress components remain substantially unchanged These results are important for a correct assessment of the structural integrity of a pumpkin balloon in a long-duration mission both in terms of the material performance and the overall stability of the shape of the balloon An experimental investigation of the time dependence of the biaxial strain distribution in the film of a 4 m diameter 48 gore pumpkin balloon is presented The inflated shape of selected gores has been measured using photogrammetry and the time variation in strain components at some particular points of these gores has been measured under constant pressure and temperature The results show good correlation with a numerical study using the ABAQUS finite-element package that includes a widely used model of

  11. Aerial Deployment and Inflation System for Mars Helium Balloons

    Science.gov (United States)

    Lachenmeler, Tim; Fairbrother, Debora; Shreves, Chris; Hall, Jeffery, L.; Kerzhanovich, Viktor V.; Pauken, Michael T.; Walsh, Gerald J.; White, Christopher V.

    2009-01-01

    A method is examined for safely deploying and inflating helium balloons for missions at Mars. The key for making it possible to deploy balloons that are light enough to be buoyant in the thin, Martian atmosphere is to mitigate the transient forces on the balloon that might tear it. A fully inflated Mars balloon has a diameter of 10 m, so it must be folded up for the trip to Mars, unfolded upon arrival, and then inflated with helium gas in the atmosphere. Safe entry into the Martian atmosphere requires the use of an aeroshell vehicle, which protects against severe heating and pressure loads associated with the hypersonic entry flight. Drag decelerates the aeroshell to supersonic speeds, then two parachutes deploy to slow the vehicle down to the needed safe speed of 25 to 35 m/s for balloon deployment. The parachute system descent dynamic pressure must be approximately 5 Pa or lower at an altitude of 4 km or more above the surface.

  12. Ballooning osteolysis in 71 failed total ankle arthroplasties.

    Science.gov (United States)

    Singh, Gurpal; Reichard, Theresa; Hameister, Rita; Awiszus, Friedemann; Schenk, Katja; Feuerstein, Bernd; Roessner, Albert; Lohmann, Christoph

    2016-08-01

    Background and purpose - Aseptic loosening is a major cause of failure in total ankle arthroplasty (TAA). In contrast to other total joint replacements, large periarticular cysts (ballooning osteolysis) have frequently been observed in this context. We investigated periprosthetic tissue responses in failed TAA, and performed an element analysis of retrieved tissues in failed TAA. Patients and methods - The study cohort consisted of 71 patients undergoing revision surgery for failed TAA, all with hydroxyapatite-coated implants. In addition, 5 patients undergoing primary TAA served as a control group. Radiologically, patients were classified into those with ballooning osteolysis and those without, according to defined criteria. Histomorphometric, immunohistochemical, and elemental analysis of tissues was performed. Von Kossa staining and digital microscopy was performed on all tissue samples. Results - Patients without ballooning osteolysis showed a generally higher expression of lymphocytes, and CD3+, CD11c+, CD20+, and CD68+ cells in a perivascular distribution, compared to diffuse expression. The odds of having ballooning osteolysis was 300 times higher in patients with calcium content >0.5 mg/g in periprosthetic tissue than in patients with calcium content ≤0.5 mg/g (p < 0.001). Interpretation - There have been very few studies investigating the pathomechanisms of failed TAA and the cause-effect nature of ballooning osteolysis in this context. Our data suggest that the hydroxyapatite coating of the implant may be a contributory factor.

  13. Development of Ultra-Thin Polyethylene Balloons for High Altitude Research upto Mesosphere

    Science.gov (United States)

    Kumar, B. Suneel; Nagendra, N.; Ojha, D. K.; Peter, G. Stalin; Vasudevan, R.; Anand, D.; Kulkarni, P. M.; Reddy, V. Anmi; Rao, T. V.; Sreenivasan, S.

    Ever since its inception four decades back, Balloon Facility of Tata Institute of Fundamental Research (TIFR), Hyderabad has been functioning with the needs of its user scientists at its focus. During the early nineties, when the X-ray astronomy group at TIFR expressed the need for balloons capable of carrying the X-ray telescopes to altitudes up to 42 km, the balloon group initiated research and development work on indigenous balloon grade films in various thickness not only for the main experiment but also in parallel, took up the development of thin films in thickness range 5 to 6 μm for fabrication of sounding balloons required for probing the stratosphere up to 42 km as the regular 2000-gram rubber balloon ascents could not reach altitudes higher than 38 km. By the year 1999, total indigenization of sounding balloon manufacture was accomplished. The work on balloon grade ultra-thin polyethylene film in thickness range 2.8 to 3.8 μm for fabrication of balloons capable of penetrating mesosphere to meet the needs of user scientists working in the area of atmospheric dynamics commenced in 2011. Pursuant to the successful trials with 61,000-m3 balloon made of 3.8-μm Antrix film reaching stratopause (48 km) for the first time in the history of balloon facility in the year 2012, fine tuning of launch parameters like percentage free lift was carried out to take the same volume balloons to higher mesospheric altitudes. Three successful flights with a total suspended load of 10 kg using 61,000-m3 balloons were carried out in the month of January 2014 and all the three balloons crossed into the mesosphere reaching altitudes of over 51 km. All the balloons flown so far are closed system with no escape ducts. Balloon fabrication, development of launch hardware, flight control instruments and launch technique for these mesospheric balloon flights are discussed in this paper.

  14. High-n ballooning modes in highly elongated tokamaks

    International Nuclear Information System (INIS)

    An analytic study of stability against high-n ballooning modes is highly elongated axisymmetric plasmas is presented and compared with computational results. - From the equation for the marginal pressure gradient, it is found that local shear has an important effect on the stability of elongated plasmas, and that stability deteriorates through high elongation since the stabilizing effects of field line bending and local shear are reduced. The net contribution of the local shear to stability decreases with elongation for strong ballooning modes (eigenfunctions strongly localized near the outer edge of the toroidal flux surfaces) but increases for interchange modes (eigenfunctions more uniform along the flux surfaces). - The computational study of high-n ballooning modes in a highly elongated plasma reveals that lowering the aspect ratio and broadening the pressure profile enhance the marginal beta for βsub(p) less than unity but severely reduce the marginal beta for βsub(p) larger than unity. (author)

  15. Extrusion process optimization for toughness in balloon films

    Science.gov (United States)

    Cantor, K. M.; Harrison, I. R.

    1993-01-01

    An experimental optimization process for blown film extrusion is described and examined in terms of the effects of the technique on the toughness of balloon films. The optimization technique by Cantor (1990) is employed which involves the identification of key process variables including screw speed, nip speed, bubble diameter, and frost-line height for analysis to optimize the merit function. The procedure is employed in the extrusion of a low-density polyethylene polymer, and the resulting optimized materials are toughness- and puncture-tested. Balloon toughness is optimized in the analytical relationship, and the process parameters are modified to attain optimal toughness. The film produced is shown to have an average toughness of 24.5 MPa which is a good value for this key property of balloon materials for high-altitude flights.

  16. Tokamak resistive magnetohydrodynamic ballooning instability in the negative shear regime

    Institute of Scientific and Technical Information of China (English)

    Shi Bing-Ren; Lin Jian-Long; Li Ji-Quan

    2007-01-01

    Improved confinement of tokamak plasma with central negative shear is checked against the resistive ballooning mode. In the negative shear regime, the plasma is always unstable for purely growing resistive ballooning mode. For a simplest tokamak equilibrium model, the s-α model, characteristics of this kind of instability are fully clarified by numerically solving the high n resistive magnetohydrodynamic ballooning eigen-equation. Dependences of the growth rate on the resistivity, the absolute shear value, the pressure gradient are scanned in detail. It is found that the growth rate is a monotonically increasing function of a while it is not sensitive to the changes of the shear s, the initial phase θ0 and the resistivity parameter εR.

  17. Ideal MHD Ballooning modes, shear flow and the stable continuum

    CERN Document Server

    Taylor, J B

    2012-01-01

    There is a well established theory of Ballooning modes in a toroidal plasma. The cornerstone of this is a local eigenvalue lambda on each magnetic surface - which also depends on the ballooning phase angle k. In stationary plasmas lambda(k) is required only near its maximum, but in rotating plasmas its average over k is required. Unfortunately in many case lambda(k) does not exist for some range of k, because the spectrum there contains only a stable continuum. This limits the application of the theory, and raises the important question of whether this "stable interval" gives rise to significant damping. This question is re-examined using a new, simplified, model - which leads to the conclusion that there is no appreciable damping at small shear flow. In particular, therefore, a small shear flow should not affect Ballooning mode stability boundaries.

  18. Ideal ballooning modes, shear flow and the stable continuum

    Science.gov (United States)

    Taylor, J. B.

    2012-11-01

    There is a well-established theory of ballooning modes in a toroidal plasma. The cornerstone of this is a local eigenvalue λ on each magnetic surface—which also depends on the ballooning phase angle k. In stationary plasmas, λ(k) is required only near its maximum, but in rotating plasmas its average over k is required. Unfortunately in many cases λ(k) does not exist for some range of k, because the spectrum there contains only a stable continuum. This limits the application of the theory, and raises the important question of whether this ‘stable interval’ gives rise to significant damping. This question is re-examined using a new, simplified, model—which leads to the conclusion that there is no appreciable damping at small shear flow. In particular, therefore, a small shear flow should not affect ballooning mode stability boundaries.

  19. Dynamic electromechanical instability of a dielectric elastomer balloon

    Science.gov (United States)

    Chen, Feifei; Zhu, Jian; Wang, Michael Yu

    2015-11-01

    Electromechanical instability, a significant phenomenon in dielectric elastomers, has been well studied in the literature. However, most previous work was based on the assumption that dielectric elastomers undergo quasi-static deformation. This letter investigates the dynamic electromechanical instability of a dielectric elastomer balloon which renders four types of oscillation subject to a parametric combination of DC and AC voltages. The simulated oscillations show that dynamic electromechanical instability occurs within quite a large range of excitation frequency, in the form of snap-through or snap-back, when the DC and AC voltages reach critical values. The balloon is at its most susceptible to dynamic electromechanical instability when the superharmonic, harmonic or subharmonic resonance is excited. Taking all excitation parameters into account, this letter analyzes the global critical condition which triggers the dynamic electromechanical instability of the balloon.

  20. To sail the skies of Mars - Scientific ballooning on the red planet

    Science.gov (United States)

    Gaidos, Eric J.; Burke, James D.

    1988-01-01

    Balloons represent a novel approach to exploring the surface of Mars. One promising aerostat system incorporates a solar-powered balloon as a means of generating diurnally varying lift and so can 'hop' across the surface, obtaining detailed information at a large number of sites. Two important areas of research and testing are underway on solar balloon technology and balloon payload design. The solar balloon concept has been demonstrated on earth, but more work is needed on a 'flyable' version for Mars. Particular attention must be paid to radiation heat transfer and aerodynamic effects. A special 'snake' payload concept has been demonstrated that allows for balloon system traverses of the surface and provides a usable instrument platform. A balloon system of this type could obtain unique surface imaging and physical and chemical data. The flight of the balloon also provides in situ atmospheric boundary-layer and circulation measurements.

  1. Membranous duodenal stenosis: Initial experience with balloon dilatation in four children

    International Nuclear Information System (INIS)

    Introduction: We present a novel approach to the treatment of membranous duodenal stenosis (MDS). To our knowledge this is the first paper to describe balloon dilatation for this entity. Material and methods: Four children, 2 boys and 2 girls, aged between 8 and 28 days, underwent duodenal balloon dilatation. Balloon dilatation was performed under general anaesthesia using standard angiography balloons per os. Balloon diameters ranged from 6 to 14 mm. Results: All balloon dilatations were successful. None of the procedures showed procedural or post-procedural complications. None of the patients subsequently required surgical intervention. To date all children are doing well. Discussion: The initial experience with balloon dilation of MDS showed a 100% success rate, without procedural or post-procedural complications. The results obtained in this small group of patients suggest that the use of balloon dilatation in cases of MDS may be a safe technique that can be readily performed by an experienced interventional radiologist

  2. Balloon vetebroplasty with calcium phosphate cement augmentation for direct restoration of traumatic thoracolumbar vertebral fractures

    NARCIS (Netherlands)

    Verlaan, JJ; van Helden, WH; Oner, FC; Verbout, AJ; Dhert, WJA

    2002-01-01

    Study Design. A human cadaveric model was used to evaluate balloon vertebroplasty in traumatic vertebral fractures. Objectives. To assess the feasibility and safety of balloon vertebroplasty followed by calcium phosphate cement augmentation to prevent recurrent kyphosis. Summary of Background Data.

  3. Near Space Lab-Rat Experimentation using Stratospheric Balloon

    Science.gov (United States)

    Buduru, Suneel Kumar; Reddy Vizapur, Anmi; Rao Tanneeru, Venkateswara; Trivedi, Dharmesh; Devarajan, Anand; Pandit Manikrao Kulkarni, MR..; Ojha, Devendra; Korra, Sakram; Neerudu, Nagendra; Seng, Lim; Godi, Stalin Peter

    2016-07-01

    First ever balloon borne lab-rat experiment up to near space stratospheric altitude levels carried out at TIFR Balloon Facility, Hydeabad using zero pressure balloons for the purpose of validating the life support system. A series of two balloon experiments conducted under joint collaboration with IN.Genius, Singapore in the year 2015. In these experiments, three lab-rats sent to stratosphere in a pressurized capsule designed to reach an altitude of 30 km by keeping constant pressure, temperature and maintained at a precise rate of oxygen supply inside the capsule. The first experiment conducted on 1 ^{st} February, 2015 with a total suspended weight of 225 kg. During the balloon ascent stage at 18 km altitude, sensors inside the capsule reported drastic drop in internal pressure while oxygen and temperatures maintained at correct levels resulted in premature fligt termination at 20.1 km. All the three lab-rats recovered without life due to the collapse of their lungs caused by the depressurization inside the capsule. The second experiment conducted on 14th March, 2015 using a newly developed capsule with rectification of depressurization fault by using improved sealing gaskets and hermitically sealed connectors for sending lab-rats again to stratosphere comprising a total suspended load of 122.3 kg. The balloon flight was terminated after reaching 29.5 km in 110 minutes and succesfully recovered all the three lab-rats alive. This paper focuses on lessons learnt of the development of the life support system as an integral pressurized vessel, flight control instrumentation, flight simulation tests using thermo-vaccum chamber with pre-flight operations.

  4. Balloon-Borne Infrasound Detection of Energetic Bolide Events

    Science.gov (United States)

    Young, Eliot F.; Ballard, Courtney; Klein, Viliam; Bowman, Daniel; Boslough, Mark

    2016-10-01

    Infrasound is usually defined as sound waves below 20 Hz, the nominal limit of human hearing. Infrasound waves propagate over vast distances through the Earth's atmosphere: the CTBTO (Comprehensive Nuclear-Test-Ban Treaty Organization) has 48 installed infrasound-sensing stations around the world to detect nuclear detonations and other disturbances. In February 2013, several CTBTO infrasound stations detected infrasound signals from a large bolide that exploded over Chelyabinsk, Russia. Some stations recorded signals that had circumnavigated the Earth, over a day after the original event. The goal of this project is to improve upon the sensitivity of the CTBTO network by putting microphones on small, long-duration super-pressure balloons, with the overarching goal of studying the small end of the NEO population by using the Earth's atmosphere as a witness plate.A balloon-borne infrasound sensor is expected to have two advantages over ground-based stations: a lack of wind noise and a concentration of infrasound energy in the "stratospheric duct" between roughly 5 - 50 km altitude. To test these advantages, we have built a small balloon payload with five calibrated microphones. We plan to fly this payload on a NASA high-altitude balloon from Ft Sumner, NM in August 2016. We have arranged for three large explosions to take place in Socorro, NM while the balloon is aloft to assess the sensitivity of balloon-borne vs. ground-based infrasound sensors. We will report on the results from this test flight and the prospects for detecting/characterizing small bolides in the stratosphere.

  5. Five-year follow-up of angiographic disease progression after medicine, angioplasty, or surgery

    Directory of Open Access Journals (Sweden)

    Oliveira Sergio A

    2010-10-01

    Full Text Available Abstract Background Progression of atherosclerosis in coronary artery disease is observed through consecutive angiograms. Prognosis of this progression in patients randomized to different treatments has not been established. This study compared progression of coronary artery disease in native coronary arteries in patients undergoing surgery, angioplasty, or medical treatment. Methods Patients (611 with stable multivessel coronary artery disease and preserved ventricular function were randomly assigned to CABG, PCI, or medical treatment alone (MT. After 5-year follow-up, 392 patients (64% underwent new angiography. Progression was considered a new stenosis of ≥ 50% in an arterial segment previously considered normal or an increased grade of previous stenosis > 20% in nontreated vessels. Results Of the 392 patients, 136 underwent CABG, 146 PCI, and 110 MT. Baseline characteristics were similar among treatment groups, except for more smokers and statin users in the MT group, more hypertensives and lower LDL-cholesterol levels in the CABG group, and more angina in the PCI group at study entry. Analysis showed greater progression in at least one native vessel in PCI patients (84% compared with CABG (57% and MT (74% patients (p Conclusion The angioplasty treatment conferred greater progression in native coronary arteries, especially in the left anterior descending territories and treated vessels. The progression was independently associated with hypertension, male sex, and previous myocardial infarction.

  6. The Mechanical Study of Vascular Endothelial Growth Factor on the Prevention of Restenosis after Angioplasty

    Institute of Scientific and Technical Information of China (English)

    LIU; Qigong; LU; Zaiying; ZHOU; Honglian; YAN; Jin; ZHANG; Weidong

    2001-01-01

    The mechanism of vascular endothelial growth factor (VEGF) on the prevention of restenosis after angioplasty was investigated. The cultured vascular endothelial cells (VEC) were incubated with the conditioned medium (CM) from vascular smooth muscle cells (VSMC) infected with recombinant adenoviruses containing the hVEGF165 gene. To observe the effects of VEGF on proliferation and NO, ET, 6-keto-PGF1α secretion of VEC, WST-1 method, Griess method and radioimmunoassay were used respectively. The PDGF-B mRNA transcription in VECs was detected by RT-PCR. It was showed that NO, 6-keto-PGF1α and OD value were markedly increased in a dosedependent manner in the VEGF-treated groups as compared with those in the control group, while ET and PDGF-B mRNA were significantly decreased in the VEGF-treated groups (P<0. 05 or P<0. 01). Adenovirus vector mediated hVEGF165 gene could promote the proliferation of VECs and im prove NO, PGI2 secretion, inhibit ET secretionand PDGF-B mRNA transcription in the VECs. Theabove results offered further theoretical evidence for VEGF on the prevention of restenosis after angioplasty.

  7. Intradural vertebral endarterectomy with nonautologous patch angioplasty for refractory vertebrobasilar ischemia: Case report and literature review

    Directory of Open Access Journals (Sweden)

    Timothy Uschold

    2014-01-01

    Full Text Available Background: The natural history of patients with symptomatic vertebrobasilar ischemic symptoms due to chronic bilateral vertebral artery occlusive disease is progressive, and poses significant challenges when refractory to medical therapy. Surgical treatment options depend largely on location and characteristics of the atheroma (s, and generally include percutaneous transluminal angioplasty (PTA with or without stent placement, posterior circulation revascularization (bypass, extracranial vertebral artery reconstruction, or vertebral artery endarterectomy. Case Description: We present the case of a 56-year-old male with progressive vertebrobasilar ischemia due to tandem lesions in the right vertebral artery at the origin and intracranially in the V4 segment. The contralateral vertebral artery was occluded to the level of posterior inferior cerebellar artery (PICA and posterior communicating arteries were absent. Following PTA and stent placement at the right vertebral artery origin, the patient was successfully treated with intradural vertebral artery endarterectomy (V4EA and patch angioplasty via the far lateral approach. Distal endovascular intervention at the V4 segment proved not technically feasible after multiple attempts. Conclusions: V4EA is an uncommonly performed procedure, but may be considered for carefully selected patients. The authors′ techniques and indications are discussed. Historical outcomes, relevant anatomic considerations, and lessons learned are reviewed from the literature.

  8. Interleukin-6 and asymmetric dimethylarginine are associated with platelet activation after percutaneous angioplasty with stent implantation.

    Science.gov (United States)

    Gremmel, Thomas; Perkmann, Thomas; Kopp, Christoph W; Seidinger, Daniela; Eichelberger, Beate; Koppensteiner, Renate; Steiner, Sabine; Panzer, Simon

    2015-01-01

    Data linking in vivo platelet activation with inflammation and cardiovascular risk factors are scarce. Moreover, the interrelation between endothelial dysfunction as early marker of atherosclerosis and platelet activation has not been studied, so far. We therefore sought to investigate the associations of inflammation, endothelial dysfunction and cardiovascular risk factors with platelet activation and monocyte-platelet aggregate (MPA) formation in 330 patients undergoing angioplasty with stent implantation for atherosclerotic cardiovascular disease. P-selectin expression, activation of glycoprotein IIb/IIIa and MPA formation were determined by flow cytometry. Interleukin (IL)-6, high sensitivity C-reactive protein and asymmetric dimethylarginine (ADMA) were measured by commercially available assays. IL-6 was the only parameter which was independently associated with platelet P-selectin expression and activated GPIIb/IIIa as well as with leukocyte-platelet interaction in multivariate regression analysis (all p<0.05). ADMA was independently associated with GPIIb/IIIa activation (p<0.05). Patients with high IL-6 exhibited a significantly higher expression of P-selectin than patients with low IL-6 (p=0.001), whereas patients with high ADMA levels showed a more pronounced activation of GPIIb/IIIa than patients with low ADMA (p=0.003). In conclusion, IL-6 and ADMA are associated with platelet activation after percutaneous angioplasty with stent implantation. It remains to be established whether they act prothrombotic and atherogenic themselves or are just surrogate markers for atherosclerosis with concomitant platelet activation.

  9. Interleukin-6 and asymmetric dimethylarginine are associated with platelet activation after percutaneous angioplasty with stent implantation.

    Directory of Open Access Journals (Sweden)

    Thomas Gremmel

    Full Text Available Data linking in vivo platelet activation with inflammation and cardiovascular risk factors are scarce. Moreover, the interrelation between endothelial dysfunction as early marker of atherosclerosis and platelet activation has not been studied, so far. We therefore sought to investigate the associations of inflammation, endothelial dysfunction and cardiovascular risk factors with platelet activation and monocyte-platelet aggregate (MPA formation in 330 patients undergoing angioplasty with stent implantation for atherosclerotic cardiovascular disease. P-selectin expression, activation of glycoprotein IIb/IIIa and MPA formation were determined by flow cytometry. Interleukin (IL-6, high sensitivity C-reactive protein and asymmetric dimethylarginine (ADMA were measured by commercially available assays. IL-6 was the only parameter which was independently associated with platelet P-selectin expression and activated GPIIb/IIIa as well as with leukocyte-platelet interaction in multivariate regression analysis (all p<0.05. ADMA was independently associated with GPIIb/IIIa activation (p<0.05. Patients with high IL-6 exhibited a significantly higher expression of P-selectin than patients with low IL-6 (p=0.001, whereas patients with high ADMA levels showed a more pronounced activation of GPIIb/IIIa than patients with low ADMA (p=0.003. In conclusion, IL-6 and ADMA are associated with platelet activation after percutaneous angioplasty with stent implantation. It remains to be established whether they act prothrombotic and atherogenic themselves or are just surrogate markers for atherosclerosis with concomitant platelet activation.

  10. BETTII: The Balloon Experimental Twin Telescope for Infrared Interferometry

    Science.gov (United States)

    Rinehart, Stephen

    2011-01-01

    Astronomical studies at infrared wavelengths have dramatically improved our understanding the universe. The relatively low angular resolution of these missions, however, is insufficient to resolve the physical scale on which mid-to far-infrared emission arises. We will build the Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII),8oeight-meter Michelson interferometer to fly on a high-altitude balloon. BETTII's spectral-spatial capability, provided by an instrument using double-Fourier techniques, will address key questions about the nature of disks io young star clusters and active galactic nuclei and the envelopes of evolved stars. BETTII will also lay the technological groundwork for future space interferometers.

  11. The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII)

    Science.gov (United States)

    Rinehart, Stephen

    2012-01-01

    The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-meter baseline far-infrared interferometer to fly on a high altitude balloon. BETTII uses a double-Fourier Michelson interferometer to simultaneously obtain spatial and spectral information on science targets; the long baseline provides subarcsecond angular resolution, a capability unmatched by other far-infrared facilities. Here, we present key aspects of the overall design of the mission and provide an overview of the current status of the project. We also discuss briefly the implications of this experiment for future space-based far-infrared interferometers.

  12. Cosmic ray abundance measurements with the CAKE balloon experiment

    CERN Document Server

    Cecchini, S; Giacomelli, G; Manzoor, S; Medinaceli, E; Patrizii, L; Togo, V

    2005-01-01

    We present the results from the CAKE (Cosmic Abundance below Knee Energy) balloon experiment which uses nuclear track detectors. The final experiment goal is the determination of the charge spectrum of CR nuclei with Z $>$ 30 in the primary cosmic radiation. The detector, which has a geometric acceptance of $\\sim$ 1.7 m$^2$sr, was exposed in a trans-mediterranean stratospheric balloon flight. Calibrations of the detectors used (CR39 and Lexan), scanning strategies and algorithms for tracking particles in an automatic mode are presented. The present status of the results is discussed

  13. Testing in a stratospheric balloon of a semiconductor detector altimeter

    International Nuclear Information System (INIS)

    An altimeter containing a semiconductor detector has been operated on flight. We have used a stratospheric balloon launched from AIRE-SUR-ADOUR with the C.N.E.S. collaboration. During this assay two apparatus have been used. The first allowed to follow the balloon during its ascension and descent, the second to follow its evolution at its maximum altitude. Informations transmitted by radio and recorded on Magnetophon, have been studied after the flight. Results are identical with these given by the barometer used by the C.N.E.S. in this essay. (authors)

  14. Balloon-Borne System Would Aim Instrument Toward Sun

    Science.gov (United States)

    Polites, M. E.

    1992-01-01

    Proposed system including digital control computer, control sensors, and control actuators aims telescope or other balloon-borne instrument toward Sun. Pointing system and instrument flown on gondola, suspended from balloon. System includes reaction wheel, which applies azimuthal control torques to gondola, and torque motor to apply low-frequency azimuthal torques between gondola and cable. Three single-axis rate gyroscopes measure yaw, pitch, and roll. Inclinometer measures roll angle. Two-axis Sun sensor measures deviation, in yaw and pitch, of attitude of instrument from line to apparent center of Sun. System provides initial coarse pointing, then maintains fine pointing.

  15. Polymer blends for LDB applications. [Long Duration Ballooning

    Science.gov (United States)

    Lichkus, Andrew M.; Harrison, Ian R.

    1991-01-01

    A series of LCP/PE blends have been studied to determine the potential of such systems to produce a high modulus balloon film material which retains the balloon fabrication and low temperature flight advantages of the current PE films. Blown films of blends of 5 and 15 percent LCP in PE have been produced which show a 28 percent enhancement in modulus over the neat PE matrix. These results are substantially lower than anticipated and are explained in terms of the LCP reinforcement aspect ratio and fibril diameter.

  16. Intimal Hyperplasia in Balloon Dilated Coronary Arteries is Reduced by Local Delivery of the NO Donor, SIN-1 Via a cGMP-Dependent Pathway

    Directory of Open Access Journals (Sweden)

    Arner Anders

    2011-06-01

    Full Text Available Abstract Background To elucidate the mechanism by which local delivery of 3-morpholino-sydnonimine (SIN-1 affects intimal hyperplasia after percutaneous transluminal coronary angioplasty (PTCA. Methods Porcine coronary arteries were treated with PTCA and immediately afterwards locally treated for 5 minutes, with a selective cytosolic guanylate cyclase inhibitor, 1 H-(1,2,4oxadiazole(4,3-alphaquinoxaline-1-one (ODQ + SIN-1 or only SIN-1 using a drug delivery-balloon. Arteries were angiographically depicted, morphologically evaluated and analyzed after one and eight weeks for actin, myosin and intermediate filaments (IF and nitric oxide synthase (NOS contents. Results Luminal diameter after PCI in arteries treated with SIN-1 alone and corrected for age-growth was significantly larger as compared to ODQ + SIN-1 or to controls (p Conclusions After PTCA local delivery of high concentrations of the NO donor SIN-1 for 5 minutes inhibited injury induced neointimal hyperplasia. This favorable effect was abolished by inhibition of guanylyl cyclase indicating mediation of a cyclic guanosine 3',5'-monophosphate (cGMP-dependent pathway. The momentary events at the time of injury play crucial role in the ensuring development of intimal hyperplasia.

  17. Cardiac troponin T and CK-MB mass release after visually successful percutaneous transluminal coronary angioplasty in stable angina pectoris

    DEFF Research Database (Denmark)

    Ravkilde, J; Nissen, H; Mickley, H;

    1994-01-01

    The incidence of cardiac troponin T (Tn-T) and creatine kinase (CK) isoenzyme MB mass release was studied in 23 patients with stable angina pectoris undergoing visually successful percutaneous transluminal coronary angioplasty (PTCA). Serial blood samples were drawn for measurement of serum Tn-T,...

  18. Comparison of costs of percutaneous transluminal coronary angioplasty and coronary bypass surgery for patients with angina pectoris

    NARCIS (Netherlands)

    C. van Halem; F. van den Brink; P.J. de Feyter (Pim); P.W.J.C. Serruys (Patrick); H. Suryapranata (Harry); K.J. Meeter; E. Bos (Egbert); F.J. van Dalen (Frederik); M.J.B.M. van den Brand (Marcel)

    1990-01-01

    textabstractTo determine the costs of a procedure, the total costs of the department that provides the service must be considered and, in addition, the direct cost of the specific procedure. Applying this principle to the cost accounting of angioplasty and bypass surgery results in a direct, i.e. pr

  19. Pharmacological approaches to the prevention of restenosis following angioplasty. The search for the Holy Grail? (part II)

    NARCIS (Netherlands)

    J.P.R. Herrman; W.R.M. Hermans (Walter); J. Vos (Jeroen); P.W.J.C. Serruys (Patrick)

    1993-01-01

    textabstractPart I of this article reviewed the results of studies investigating the effectiveness of antithrombotic, antiplatelet, antiproliferative, anti-inflammatory, calcium channel blocker and lipid-lowering drugs in preventing or reducing restenosis after angioplasty. However, despite 15 years

  20. Prolonged binding of radiolabeled recombinant tissue-type plasminogen activator after angioplasty and enclosed thrombolysis of the femoropopliteal arteries

    DEFF Research Database (Denmark)

    Tønnesen, K H; Vinberg, N; Folkenborg, O

    1992-01-01

    The authors measured the binding of indium-111-labeled recombinant tissue-type plasminogen activator (rt-PA) within the recanalized femoropopliteal segment after percutaneous transluminal angioplasty (PTA) and enclosed thrombolysis. In patients with long occlusions (n = 3), 91 micrograms of rt...

  1. A successful patch angioplasty with auto-pulmonary wall for congenital coronary left main trunk occlusion in a young child.

    Science.gov (United States)

    Terada, Takafumi; Sakurai, Hajime; Nonaka, Toshimichi; Sakurai, Takahisa; Sugiura, Junya; Taneichi, Tetsuyoshi; Ohtsuka, Ryohei

    2015-12-01

    Congenital occlusion of the left main coronary trunk is a life-threatening abnormality, and its optimal management remains controversial. This report describes a case of successful patch angioplasty with auto-pulmonary artery for a 12-year-old boy with congenital left main trunk occlusion. We divided the main pulmonary artery, harvested a pulmonary artery wall strip, and performed patch angioplasty of the occluded left main trunk ostium. We were able to clearly expose the left main trunk behind the pulmonary artery because the obstruction was divided for the patch material. The postoperative course was uneventful, and coronary angiography at 4 months after surgery showed excellent patency of the left main trunk. The auto-pulmonary arterial wall was easy to handle during angioplasty, and its favorable durability has been established both in the Ross procedures and in an arterial switch procedure. Therefore, we conclude that patch angioplasty using a piece of the pulmonary arterial wall represents a good alternative to conventional coronary artery bypass grafting.

  2. Successful percutaneous transluminal angioplasty and stenting for symptomatic intracranial vertebral artery stenosis using intravascular ultrasound virtual histology.

    Science.gov (United States)

    Takayama, Katsutoshi; Taoka, Toshiaki; Nakagawa, Hiroyuki; Myouchin, Kaoru; Wada, Takeshi; Sakamoto, Masahiko; Fukusumi, Akio; Iwasaki, Satoru; Kurokawa, Shinichiro; Kichikawa, Kimihiko

    2007-06-01

    This is the first report of percutaneous transluminal angioplasty (PTA) of an intracranial artery applying intravascular ultrasound virtual histology (IVUS-VH), which has been recently developed for tissue characterization of coronary artery plaque. We report a case of successful PTA and stenting for symptomatic intracranial vertebral artery stenosis using IVUS-VH.

  3. Long-term follow-up after embolization of pulmonary arteriovenous malformations with detachable silicone balloons

    DEFF Research Database (Denmark)

    Andersen, Poul Erik; Kjeldsen, Anette D

    2007-01-01

    ) with pulmonary angiography. Fifty-four percent of the balloons were deflated at latest radiographic chest film follow-up, but at pulmonary angiographic follow-up all embolized malformations were without flow irrespective of whether or not the balloons were visible. Detachable silicone balloons are not...

  4. Evaluation of percutaneous transluminal angioplasty for treatment of infrapopliteal arteriosclerosis obliterans%经皮腔内血管成形术治疗膝下动脉粥样硬化闭塞症的评价

    Institute of Scientific and Technical Information of China (English)

    张玉超; 黄英; 李维敏; 陆信武; 黄新天; 陆民; 蒋米尔

    2012-01-01

    Objective To assess the therapeutic effect of percutaneous transluminal angioplasty ( PTA )on the treatment of infrapopliteal arteriosclerosis obliterans( ASOs ). Methods From Jan. 2007 to Jun. 2011, clinical data of patients with infrapopliteal ASO undergoing PTA at our department were retrospectively reviewed. Results Infrapopliteal PTA was performed on 138 lower limbs for 138 patients( mean age,77. 31 ±7. 52 year - old ). The mean diameter of balloon catheters used for infrapopliteal arteries was 2. 8 mm( 2 mm ~4 mm ), with the mean length of 110. 6 mm( 40 mm ~ 170 mm ). There were no severe complications occurring intraoperatively or postoperatively. Early results showed that all patients had significant improvement in ischemic symptoms( 100% ), and no patients had limb loss. During a mean follow -up of 24. 1 months( 4 ~ 58 months ), the rate of improvement in ischemic symptoms for treated limbs was 78. 4% and the limb salvage rate was 93. 9% at 2 years. Conclusion Minimal invasive PTA for the treatment of infrapopliteal ASO is safe and effective for improving ischemic symptoms of lower limbs and limb salvage.%目的 评价经皮腔内血管成形术(percutaneous transluminal angioplasty,PTA)治疗膝下动脉粥样硬化闭塞症(arteriosclerosis obliterans,ASO)的疗效.方法 回顾性研究2007年1月至2011年6月我科收治的累及膝下动脉ASO并行PTA治疗的患者的临床资料.结果 138例患者,平均年龄(77.31±7.52)岁,治疗膝下动脉所用球囊平均直径 2.8mm(2~4mm),平均长度110.6mm(40~170mm),术中及术后无严重并发症.术后早期治疗肢体临床症状明显改善率为100%,无截肢患者.平均随访24.1个月(4~58个月),治疗肢体术后2年临床症状明显改善率78.4%,救肢率93.9%.结论 PTA治疗膝下动脉ASO可有效改善临床缺血症状并提高救肢率.

  5. [Intra-graft balloon pumping--a clinical case report].

    Science.gov (United States)

    Nagata, M; Tashiro, T; Tanaka, K; Haruta, Y; Todo, K

    1991-12-01

    A 29-year-old female underwent tube graft replacement of distal aortic arch and descending aorta for dissecting aneurysm. After 42 minutes of aortic cross-clamping the patient was initially weaned satisfactorily from cardiopulmonary bypass (CPB). However, cardiac arrhythmia and cardiac arrest necessitated reestablishment of CPB. Electro-cardiography showed inferior myocardial infarction. To wean CPB intraaortic balloon pumping (IABP) was mandatory. But because of dissecting aortic aneurysm IABP in conventional method was contra-indicated. Intra graft balloon pumping (IGBP) was initiated while the patient was on full CPB. A low-porosity woven Dacron tube graft (22 mm) was anastomosed end-to-side to ascending aorta. A balloon was inserted into the tube graft to establish IGBP. This IGBP provided effective circulatory assist. The patient was weaned from CPB 1 hours after reestablishment of IGBP. Postoperative course was stable. The patient was returned to the operating room for removal of the balloon 3 days postoperatively. We reported the case for whom IGBP was effective. IGBP was effective circulatory support for the patient when conventional use of IABP was contra-indicated. PMID:1774515

  6. Complications of flow-directed balloon-tipped catheters.

    Science.gov (United States)

    Smart, F W; Husserl, F E

    1990-01-01

    Acute or short-term complications following the use of flow-directed balloon-tipped catheters are well recognized. Long-term sequelae are rarely reported. We report herein an early complication of pulmonary arterial rupture with infarction followed by the delayed development of a pulmonary arterial aneurysm.

  7. Balloon atrial septostomy under echocardiographic guide: case series

    Directory of Open Access Journals (Sweden)

    SM Meraji

    2012-12-01

    Full Text Available Background: Balloon atrial septostomy is an emergent procedure in pediatric cardiology. Nowadays, most patients in need of the procedure have acceptable outcomes after surgical repair. Thus, it is important to perform this procedure as safe as possible. By performing early arterial switch operation and prostaglandin infusion, the rate of balloon atrial septostomy has markedly decreased. However, not all centers performing early arterial switch repairs have abandoned atrial septostomy, even in patients who respond favorably to prostaglandin infusion.Case presentation: In total, eight 1- to 15-day old term neonates admitted in Shahid Rajaee Heart Center in Tehran, Iran from October 2009 to February 2011, with congenital heart diseases were scheduled for balloon atrial septostomy. In six cases the procedure was done exclusively under echocardiographic guidance and in two cases with the help of fluoroscopy. Success was defined as the creation of an atrial septal defect with a diameter equal to or more than 5 mm and ample mobility of its margins.Results: Male sex was predominant (87% and the mean age of the neonates was six days. The diagnosis in all cases was simple transposition of great arteries. The procedure was successful in all patients with any cardiovascular complication.Conclusion: Balloon atrial septostomy is an emergent procedure that can be done safely and effectively under echocardiographic guidance. According to the feasibility of this technique it could be performed fast, safe and effective at bedside, avoiding patient transportation to hemodynamic laboratory or referral center.

  8. Balloon dilatation of the esophageal stricture in infants and children

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Sung Wook; Kim, In One; Kim, Woo Sun; Yeon, Kyung Mo; Kim, Woo Ki; Park, Kwi Won; Han, Man Chung [Seoul Natioal University College of Medicine, Seoul (Korea, Republic of); Lee, Gi Jae [Inje University Paik Hospital, Seoul (Korea, Republic of); Yu, Pil Mun [Dankuk University College of Medicine, Seoul (Korea, Republic of)

    1992-09-15

    Balloon dilatation has been applied in treating of various pathologic narrowing of the hollow viscus. It is now accepted as a very effective modality especially in treating esophageal stenosis obviating surgical procedure. We performed 128 balloon dilatations in 29 patients with the number of dilatations in each patient ranging from once to 12 times. The age distribution of the patients was from 3 weeks to 6 years, with the median age of 3 months. Twenty nine patients consisted of 25 postoperative esophageal strictures (21 esophageal atresia with tracheoesophageal fistula, 1 congenital esophageal stenosis, 2 tracheobronchial remnant, and 1 congenital esophageal stenosis with esophageal atresia), 2 achalasia, 1 congenital esophageal stenosis, and 1 corrosive esophagitis. We had successful dilatation in 22 patients, who showed subsequent relief of symptoms and improvement in the diameter of stenotic segment. In 14 patients, esophageal perforation occurred during the procedure, one requiring emergency thoracotomy and the other three conservative management. Seven patients had no improvement in stenotic sites after several balloon dilatations. Failed cases were congenital stenosis, achalasia, corrosive esophagitis and four postoperative strictures. We believe that balloon dilatation is the procedure of choice in the treatment of postoperative esophageal stricture in infants and children and is a safe method as the perforation which can complicate the procedure could be managed conservatively.

  9. Scientific Ballooning Technologies Workshop STO-2 Thermal Design and Analysis

    Science.gov (United States)

    Ferguson, Doug

    2016-01-01

    The heritage thermal model for the full STO-2 (Stratospheric Terahertz Observatory II), vehicle has been updated to model the CSBF (Columbia Scientific Balloon Facility) SIP-14 (Scientific Instrument Package) in detail. Analysis of this model has been performed for the Antarctica FY2017 launch season. Model temperature predictions are compared to previous results from STO-2 review documents.

  10. Investigating obscure gastrointestinal bleeding : capsule endoscopy or double balloon enteroscopy?

    NARCIS (Netherlands)

    Westerhof, J.; Weersma, R. K.; Koornstra, J. J.

    2009-01-01

    The possibility to visualise the small bowel has dramatically improved with the introduction of capsule endoscopy (CE) and double balloon enteroscopy (DBE). CE and DBE have become standard practice in investigating suspected diseases of the small bowel. An important reason to perform small bowel inv

  11. Hot Air Balloon: An Unusual Cause of Multicasualty Trauma Incident.

    Science.gov (United States)

    Persoz, Marc-Olivier; Dami, Fabrice; Ciavatta, Ettore; Vallotton, Laurent; Albrecht, Roland; Carron, Pierre-Nicolas

    2016-01-01

    Hot air balloon incidents are few and far between compared with the total number of flights. Nevertheless, hot air balloon incidents may produce severe trauma involving several patients and are linked to significant mortality. The prehospital management of injured patients starts after having secured potential surrounding dangers, such as fire or explosion. In the context of a rescue by helicopter, close attention must be paid to potential obstacles, like trees or electrical wires, and the risk of aspiration of the balloon envelope into the rotor. Patients involved in such incidents are often split up in a closed perimeter around the crash point. The severity of the trauma depends essentially on the height of the fall. The most frequent traumatic lesions involve fractures of the lower limbs, the spine, and the pelvis as well as severe burns caused by the balloon fire. Because of the number of patients present, an initial triage is usually required at the site. The use of rescue helicopters can be helpful. They can perform aerial reconnaissance, provide on-site high-level resources, enable access to the patients even in hostile environments, and quickly transport them to trauma center hospitals. PMID:27255882

  12. Latex micro-balloon pumping in centrifugal microfluidic platforms.

    Science.gov (United States)

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Harun, Sulaiman Wadi; Al-Faqheri, Wisam; Thio, Tzer Hwai Gilbert; Kazemzadeh, Amin; Madou, Marc

    2014-03-01

    Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-step processes on a single microfluidic disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a latex membrane is introduced. It operates at low rotational speeds and pumps a larger volume of liquid towards the centre of the disc. Two different micro-balloon pumping mechanisms have been designed to study the pump performance at a range of rotational frequencies from 0 to 1500 rpm. The behaviour of the micro-balloon pump on the centrifugal microfluidic platforms has been theoretically analysed and compared with the experimental data. The experimental data show that the developed pumping method dramatically decreases the required rotational speed to pump liquid compared to the previously developed pneumatic pumping methods. It also shows that within a range of rotational speed, a desirable volume of liquid can be stored and pumped by adjusting the size of the micro-balloon.

  13. Meshed-Pumpkin Super-Pressure Balloon Design

    Science.gov (United States)

    Jones, Jack; Yavrouian, Andre

    2003-01-01

    An improved, lightweight design has been proposed for super-pressure balloons used to carry scientific instruments at high altitudes in the atmosphere of Earth for times as long as 100 days. [A super-pressure balloon is one in which the pressure of the buoyant gas (typically, helium) is kept somewhat above ambient pressure in order to maintain approximately constant density and thereby regulate the altitude.] The proposed design, called "meshed pumpkin," incorporates the basic concept of the pumpkin design, which is so named because of its appearance. The pumpkin design entails less weight than does a spherical design, and the meshed-pumpkin design would reduce weight further. The basic idea of the meshed-pumpkin design is to reinforce the membrane of a pumpkin balloon by attaching a strong, lightweight fabric mesh to its outer surface. The reinforcement would make it possible to reduce the membrane mass to one-third or less of that of the basic pumpkin design while retaining sufficient strength to enable the balloon to remain at approximately constant altitude for months.

  14. [Expansion dilatation balloons for cervical ripening in obstetric practice].

    Science.gov (United States)

    Ducarme, G; Grange, J; Vital, M

    2016-02-01

    During recent decades, mechanical devices have been substituted by pharmacological methods. Their place in the therapeutic arsenal remains important with a renewed obstetrical interest for these devices. Due to a lack of data they are still not recommended as first-line. This review thus attempted to examine the use of expansion dilatation balloons (Foley catheter and double-balloons) to analyze their effectiveness in case of native uterus and previous cesarean section. Twenty-seven clinical trials had compared balloons catheter and prostaglandins in patients without a history of uterine scar. The risk of cesarean section did not differ. Mechanical methods seemed to be more effective in achieving delivery within 24hours, with fewer episodes of excessive uterine contractions, but they necessitated more oxytocin during labor. Ten clinical trials analyzed dilatation balloons in patients with previous cesarean section. More than 70% women had favorable cervical ripening (Bishop score>6), and vaginal delivery was reported between 35 and 70% of patients. The risk of uterine rupture was low between 0.64 and 0.72%, with neither increased risk of severe neonatal and maternal morbidity nor increased risk of infectious morbidity. Mechanical methods are effective and safe for third trimester cervical ripening, mainly in women with previous cesarean section. Potential advantages may include wide availability and reduction of some of the side effects. PMID:26774842

  15. Stability of infernal and ballooning modes in advanced tokamak scenarios

    NARCIS (Netherlands)

    Holties, H. A.; Huysmans, G. T. A.; Goedbloed, J. P.; Kerner, W.; Parail, V.V.; Soldner, F. X.

    1996-01-01

    A numerical parameter study has been performed in order to find MHD stable operating regimes for advanced tokamak experiments In this study we have concentrated on internal modes. Ballooning stability and stability with respect to infernal modes are considered. The calculations confirm that pressure

  16. Balloon-assisted coiling through a 5-French system

    International Nuclear Information System (INIS)

    We present a catheter technique that utilizes a 5F system for the purpose of balloon-assisted coiling in the setting of intracranial aneurysms. A standard 5F short sheath is placed in the common femoral artery, and a 5F diagnostic catheter is placed through the sheath and used for selective vessel angiography. When endovascular intervention is pursued, the diagnostic catheter is placed in the appropriate vessel and systemic heparinization is ensured. Over an exchange length wire, the 5F vertebral catheter and 5F short sheath are exchanged for a 5F Shuttle (Cook) sheath. We then routinely place a 10, 14 or 18 microcatheter over an appropriately gauged microguidewire into the aneurysm. As needed, balloon catheters are then placed across the neck of the aneurysm for remodeling purposes. During the course of the procedure, control angiography is performed through the Shuttle sheath. Following the placement of coils, the microcatheter and balloon catheter are removed and a final biplane image is obtained via the 5F Shuttle sheath. This technique has been employed in 15 patients who required balloon-assisted coiling of an intracranial aneurysm. There were no technical difficulties or arterial access site complications from the procedures. Catheter mobility and torque were not affected, nor was the quality of our imaging. We conclude that this small-diameter system provides ample ''room'' for catheter placement and interventional treatment while reducing the known risks of postprocedural complications. Angiographic images remain excellent and are comparable to those obtained by larger catheters. (orig.)

  17. Using Hydrogen Balloons to Display Metal Ion Spectra

    Science.gov (United States)

    Maynard, James H.

    2008-01-01

    We have optimized a procedure for igniting hydrogen-filled balloons containing metal salts to obtain the brightest possible flash while minimizing the quantity of airborne combustion products. We report air quality measurements in a lecture hall immediately after the demonstration. While we recommend that this demonstration be done outdoors or in…

  18. Does endovascular treatment of infra-inguinal arterial disease with drug-eluting stents offer better results than angioplasty with or without bare metal stents?

    Science.gov (United States)

    Antoniou, George A; Georgakarakos, Efstratios I; Antoniou, Stavros A; Georgiadis, George S

    2014-08-01

    A best evidence topic in vascular and endovascular surgery was developed according to a structured protocol. The question addressed was whether treatment of infra-inguinal arterial occlusive disease with drug-eluting stents (DESs) provides improved outcomes compared with bare metal stents (BMSs) or percutaneous balloon angioplasty (PTA) alone. Altogether, 136 papers were found using the reported searches, of which 5 provided the best evidence to answer the question. All papers represent either level 1 or 2 evidence. The authors, journal, date, country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Main outcome measures varied among the studies, and included patency, in-stent restenosis, target lesion revascularization, major adverse events, clinical improvement and limb salvage. Evidence on the comparative efficacy of DESs in femoro-popliteal arterial disease is mainly based on two randomized, controlled trials. Paclitaxel-eluting stents were evaluated in the Zilver PTX trial and demonstrated superior 2-year results to either BMSs or PTA, as indicated/shown by patency (DES vs PTA, 74.8 vs 26.5%, P < 0.01), clinical benefit (DES vs PTA, P < 0.01) and event-free survival (DES vs PTA, 86.6 vs 77.9%, P = 0.02). However, the SIROCCO trial found that the sirolimus-eluting stent did not exhibit statistically significant differences in 2-year in-stent restenosis (22.9 vs 21.1%) and target lesion revascularization (6 vs 13%) compared with the BMS. Treatment of infra-politeal arterial disease with DESs was related with superior outcomes to those of BMSs, as indicated/shown by patency, freedom from target lesion revascularization and freedom from major adverse events. Furthermore, the ACHILLES trial, the only published trial comparing the infra-popliteal DES with PTA, revealed lower angiographic restenosis (22.4 vs 41.9%, P = 0.019) and greater vessel patency (75 vs 57.1%, P = 0.025) in the DES group at 1 year

  19. Lightweight Liquid Helium Dewar for High-Altitude Balloon Payloads

    Science.gov (United States)

    Kogut, Alan; James, Bryan; Fixsen, Dale

    2013-01-01

    Astrophysical observations at millimeter wavelengths require large (2-to-5- meter diameter) telescopes carried to altitudes above 35 km by scientific research balloons. The scientific performance is greatly enhanced if the telescope is cooled to temperatures below 10 K with no emissive windows between the telescope and the sky. Standard liquid helium bucket dewars can contain a suitable telescope for telescope diameter less than two meters. However, the mass of a dewar large enough to hold a 3-to-5-meter diameter telescope would exceed the balloon lift capacity. The solution is to separate the functions of cryogen storage and in-flight thermal isolation, utilizing the unique physical conditions at balloon altitudes. Conventional dewars are launched cold: the vacuum walls necessary for thermal isolation must also withstand the pressure gradient at sea level and are correspondingly thick and heavy. The pressure at 40 km is less than 0.3% of sea level: a dewar designed for use only at 40 km can use ultra thin walls to achieve significant reductions in mass. This innovation concerns new construction and operational techniques to produce a lightweight liquid helium bucket dewar. The dewar is intended for use on high-altitude balloon payloads. The mass is low enough to allow a large (3-to-5-meter) diameter dewar to fly at altitudes above 35 km on conventional scientific research balloons without exceeding the lift capability of the balloon. The lightweight dewar has thin (250- micron) stainless steel walls. The walls are too thin to support the pressure gradient at sea level: the dewar launches warm with the vacuum space vented continuously during ascent to eliminate any pressure gradient across the walls. A commercial 500-liter storage dewar maintains a reservoir of liquid helium within a minimal (hence low mass) volume. Once a 40-km altitude is reached, the valve venting the vacuum space of the bucket dewar is closed to seal the vacuum space. A vacuum pump then

  20. Angiography for renal artery stenosis: no additional impairment of renal function by angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Lufft, Volkmar; Fels, Lueder M.; Egbeyong-Baiyee, Daniel; Olbricht, Christoph J. [Abteilung Nephrologie, Medizinische Hochschule Hannover (Germany); Hoogestraat-Lufft, Linda; Galanski, Michael [Abteilung Diagnostische Radiologie, Medizinische Hochschule Hannover (Germany)

    2002-04-01

    The aim of this study was to compare renal function between patients with renal angiography and patients with renal angiography and angioplasty (AP) for renal artery stenosis (RAS). Forty-seven patients with suspected RAS were prospectively investigated by digital subtraction angiography (DSA) using non-ionic low osmolar contrast media (CM). In 22 patients RAS was detected and in 16 cases an angioplasty was performed in the same session. The following parameters were determined 1 day prior to and after the DSA, respectively: serum creatinine (S-Crea, {mu}mol/l) and single-shot inulin clearance (In-Cl, ml/min) for the evaluation of renal function; and urine alpha 1-microglobuline (AMG, {mu}g/g Crea) and beta-N-acetyl-glucoseaminidase (beta-NAG, U/g Crea) as markers of tubular toxicity. Serum creatinine was measured additionally 2 days after CM had been injected. In both groups with and without AP 174{+-}65 and 104{+-}56 ml of CM (p<0.0005) were used, respectively. There were no differences with regard to renal function or risk factors for CM nephrotoxicity between both groups. In the group with AP S-Crea and In-Cl (each: mean{+-}SD) did not change significantly (before DSA: 171{+-}158 and 61{+-}24, after DSA: 189{+-}177 and 61{+-}25, respectively), beta-NAG (median) rose from 4 to 14 (p<0.05) and AMG from 8 to 55 (n.s., because of high SD). In the group without AP S-Crea increased from 134{+-}109 to 141{+-}113 (p<0.01), In-Cl dropped from 65{+-}26 to 62{+-}26 (p<0,01), beta NAG (median) rose from 4 to 8 (p=0.01), and AMG from 7 to 10 (n.s.). A rise in baseline S-Crea by more than 25% or 44 {mu}mol/l occurred in 4 and 2 patients in the group with and without AP, respectively. Creatinine increase was reversible in all cases within 7 days. In this study using sensitive methods to detect changes of renal function and tubular toxicity no additional renal function impairment in DSA with angioplasty for RAS compared with DSA alone could be demonstrated. Our data suggest

  1. Prevalence and prognostic implications of non-sustained ventricular tachycardia in ST-segment elevation myocardial infarction after revascularization with either fibrinolysis or primary angioplasty

    DEFF Research Database (Denmark)

    Høfsten, Dan Eik; Wachtell, Kristian; Lund, Birgit;

    2007-01-01

    AIMS: We compared the prevalence and prognostic implications of non-sustained ventricular tachycardia (nsVT) detected early after ST-segment elevation myocardial infarction (STEMI) in patients randomized to either fibrinolysis or primary angioplasty in the DANAMI-2 trial. METHODS AND RESULTS......: Holter recordings were available in 1017 patients (fibrinolysis: n=501; primary angioplasty: n=516). Primary endpoint was all-cause mortality. The prevalence of nsVT was 8.8% in fibrinolysis-treated, and 8.1% in primary angioplasty-treated patients (P=0.71). During 4519 patient-years of follow-up (median...... 4.3 years), 116 patients died [fibrinolysis vs. angioplasty: HR=1.1 (95% CI, 0.8-1.6), P=0.47]. In univariate analysis, nsVT patients treated with fibrinolysis, had significantly higher mortality when compared with those without nsVT (P

  2. [The role of ionized radiation in prevention of restenosis after coronary angioplasty].

    Science.gov (United States)

    Przewłocki, T; Pieniazek, P; Tracz, W; Kostkiewicz, M; Olszowska, M; Podolec, P

    1997-01-01

    Restenosis occurs to be an Achilles heel of coronary interventions. Three overlapping processes: elastic recoil, neointimal proliferation and arterial remodelling are responsible for development of arterial renarrowing. The only method which proved efficient in reducing the restenosis rate is coronary stenting. Stents deployed using high pressure technique diminish restenosis rate by about one third. Stents eliminate elastic recoil and arterial remodelling but aggravate neointimal proliferation. A concept of radiation therapy was introduced to solve the problem of neointimal hyperplasia. Experiments on animal models of restenosis proved that both gamma as well as beta irradiation inhibited neointimal proliferation after arterial injury. Results of experimental investigations concerning both intraarterial irradiation during angioplasty as well as radioactive stent implantation are reviewed. Authors discuss also results of first clinical trials, the design and preliminary results of some larger studies like PARIS, SCRIPPS, GENEVA, BERT, IRIS, WRIST. Further investigational directions in intravascular radiation therapy are also presented. PMID:9591455

  3. Budd-Chiari and inferior caval vein syndromes due to membranous obstruction of the liver veins. Successful treatment with angioplasty and transcaval TIPS

    DEFF Research Database (Denmark)

    Holland-Fischer, Peter

    2004-01-01

    -up the stents remain open and the patient is symptom free. This successful combination of stent placement and TIPS has not been described before. The case report is followed by a review of the literature on the use of angioplasty in short hepatic vein stenosis and TIPS in Budd-Chiari syndrome. It is concluded...... that angioplasty and TIPS are safe and efficient procedures to reduce liver engorgement and complications of portal hypertension in selected patients with Budd-Chiari syndrome....

  4. Using High Resolution Balloon Photography to Provide Topographic Data

    Science.gov (United States)

    Russell, K.; Bauer, T.

    2009-12-01

    For site-scale projects, the Bureau of Reclamation has used low altitude balloon photogrammetry to obtain high-resolution photographs and detailed topographic information. These data are collected in a fraction of the time and effort it would take to obtain a similar level of detail using traditional methods. This is accomplished at a significantly reduced cost compared to flying LiDAR or aerial photography, which can be prohibitively expensive for small or medium scale projects. Low altitude balloon photogrammetry is a process where overlapping photographs and ground survey control points are input into a photogrammetry software program (AdamTechnology 3DM Analyst Mine Mapping Suite) to produce orthophotographs and digital terrain model (DTM) elevation points. To acquire the photos a digital camera is attached to an 8-foot diameter helium balloon. The balloon is tethered and flown above the location of interest. The camera is controlled remotely while a live image is transmitted to a receiver on the ground. Ground survey control is established by using GPS equipment to survey ground targets placed within the area to be photographed. There are limitations to the process. Data collection is very weather dependent; too much wind causes the balloon to be unstable. Site conditions also determine the feasibility: power lines, trees, and steep embankments can cause difficulties maneuvering the balloon. Although some of the photographs show the underwater portion of the channel; there is little agreement between GPS points and the processed DTM elevations in the channel. The balloon has been used to survey large woody debris (LWD) structures and channel morphology in the Middle Fork John Day River (central Oregon) and monitoring debris after the removal of Chiloquin Dam (Sprague River, southern Oregon). Seventeen LWD structures were installed on the Middle Fork John Day River near John Day, OR in 2007 and 2008 to provide aquatic habitat. Balloon photos were obtained in

  5. MYOCARDIAL PERFUSION ASSESSMENT IN FORECASTING EFFECT OF CORONARY ANGIOPLASTY IN PATIENTS WITH ISCHEMIC CHRONIC HEART FAILURE

    Directory of Open Access Journals (Sweden)

    A. B. Mironkov

    2015-01-01

    Full Text Available Aim. To define influence of the left ventricle (LV perfusion defects on the clinical status dynamics after coronary angioplasty in patients with the expressed myocardium dysfunction of ischemic etiology. Materials and methods. Examined 86 patients (81 men and 5 women aged from 46 to 73 years before and in 2–3 days after percutaneous coronary intervention with diagnosis: CAD, CHF with NYHA class III–IV, echocardiography parameters of LV: ejection fraction less than 40%, end-diastolic volume is more than 200 ml. Perfusion defects of myocardium estimated with use of ECG-gated single photon emission computed tomography. Predictors were defined: perfusion defects on LV apex (in score, perfusion defects in the area of LAD, LCx and RCA (%, the LV global perfusion defects (in score and %. Results. In 42% of cases 6-minute walk test increased to 3 times; The NYHA class decreased by 2 classes (group 1. In 28 cases 6-minute walk test increased to 2 times and the NYHA class decreased on 1 class. In 22 patients 6-minute walk test increased less than 50% of reference values and there was no dynamics NYHA class (50 patients of the group 2. Initial extent of LV global perfusion defects in group 1 – 41,2 ± 4,0%, in group 2 – 58,3 ± 2,4% (р = 0,0004. Similar values are received for perfusion indicators in the area of LAD and the LV apex. Prevalence of myocardial perfusion defects at rest reflects prevalence of a cardiosclerosis in a cardiac muscle. Conclusion. Degree of LV myocardial perfusion defects in patients with the expressed heart failure of ischemic etiology is the key indicator influencing clinical efficiency of coronary angioplasty. Critical size for definition of the favorable forecast of revascularization are 60% and more perfusion defects testifying that in a cardiac muscle the focal cardiosclerosis prevails over the functioning myocardium. 

  6. Patient Experience, Pain, and Quality of Life after Lower Limb Angioplasty: A Multisite Prospective Cohort Study

    Energy Technology Data Exchange (ETDEWEB)

    Culverwell, A. D., E-mail: adamculverwell@doctors.net.uk [Leeds General Infirmary (United Kingdom); Tapping, C. R.; Ettles, D. F. [Hull Royal Infirmary (United Kingdom); Kessel, D. [Leeds General Infirmary (United Kingdom)

    2012-08-15

    Purpose: To explore the experience of patients undergoing endovascular lower limb angioplasty and evaluate the improvements in quality of life and disease-related symptoms after the procedure. Methods: Patients completed a questionnaire before treatment and three questionnaires after the procedure (immediately after the procedure, and again 4 weeks and 3 months later). Anxiety, patient understanding, procedure-related pain, and disease-related pain were assessed by a visual analog score (VAS). Complications, analgesic requirements, and satisfaction were recorded. Changes to quality of life were assessed by the validated SF36 questionnaire. Results: A total of 88 patients (41%) responded. Overall, disease-related pain decreased over 3 months after the procedure. Smokers had more pain both before and after the procedure (P < 0.05). Explanation was considered better if provided by radiologist (P < 0.05). Sixty-nine percent of patients found the procedures less painful (mean VAS 2.5) than they had anticipated (VAS 5.5). Fifty percent of patients experienced adverse effects related to their puncture site, but this was highest among patients who had undergone the procedure before and smokers. The greatest quality-of-life improvements were in emotional and general health. Higher levels of disease-related pain were associated with worse general, emotional, and physical health (P < 0.05). Conclusion: Lower limb angioplasty provides symptomatic and quality-of-life improvements. Implementation of simple measures could improve patient satisfaction-for example, treatment should be explained by the radiologist in advance. Routine prescription of analgesics with particular attention to smokers and those undergoing repeat interventions is suggested.

  7. The influence of admission glucose on epicardial and microvascular flow after primary angioplasty

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Background Patients with elevated admission glucose levels may be at increased risk of death after myocardial infarction, independent of other baseline risk factors and more severe coronary artery disease. However, data regarding admission glucose and epicardial and microvascular flow after primary angioplasty is limited.Methods Angioplasty was performed in 308 ST-segment elevated myocardial infarction patients. Patients were divided into 3 groups on the basis of admission glucose level: group 1, <7.8 mmol/L; group 2, (7.8 - 11.0) mmol/L; and group 3, ≥11.0 mmol/L. Results Compared with group 1, patients in group 2 and group 3 were more often female and older. Triglycerides (TG) in group 3 were significantly higher than group 1. At angiography, they more frequently had 2-vessel or 3-vessel disease. In the infarct-related artery, there was no relationship between hyperglycemia and thrombolysis in myocardial infarction (TIMI) 3 flow after percutaneous coronary intervention (PCI) (89.7%, 86.0% and 86.3%, P=NS). However, corrected TIMI frame count (CTFC) in group 2 and group 3 were more than group 1. TIMI myocardial perfusion grade (TMPG) 0-1 grade among patients with hyperglycemia after PCI were more frequent (30.9% and 29.0% vs 17.3%, P<0.05). There was less frequent complete ST-segment resolution (STR) and early T wave inversion among patients with hyperglycemia after PCI. Conclusion Elevated admission glucose levels in ST-segment elevation myocardial infarction patients treated with primary PCI are independently associated with impaired microvascular flow. Abnormal microvascular flow may contribute at least in part to the poor outcomes observed in patients with elevated admission glucose.

  8. Eventos adversos e motivos de descarte relacionados ao reuso de produtos médicos hospitalares em angioplastia coronária Adverse events and reasons for discard related to the reuse of cardiac catheters in percutaneous transluminal coronary angioplasty

    Directory of Open Access Journals (Sweden)

    Margarete Ártico Batista

    2006-09-01

    the brand-new and reuse of medical equipment. METHOD: Sixty patients were studied (48.3% with unstable angina, 45% with acute myocardial infarction and 6.7% with other diagnoses. During the procedure and stay in the Intensive Coronary Unit, the occurrence of fever, hypotension or hypertension, chills, sudoresis, bleeding, nausea and vomits were observed. Seven products were evaluated: catheter introducer, catheter guides (0.35 and 0.014, catheter balloons for angioplasty, indeflators and manifolds. In total, 76 brand-new and 410 reused apparatuses were studied to verify the occurrence of discard, whether this happened before or during the procedure and for what reasons. P-values < 0.05 were considered signicant. RESULTS: Twenty-six patients presented adverse effects. Hypotension was the most common seen in 11(18.3% cases. There was no significant association between this adverse effect and reuse or not of the equipment. Three brand-new products and 55 of the reused products were discarded as they were incomplete. CONCLUSION: The adverse effects presented by patients submitted to coronary vessel angioplasty were not associated to the reuse of the medical equipment. The integrity and functionality were the main reasons of discard.

  9. Designing the Balloon Experimental Twin Telescope for Infrared Interferometry

    Science.gov (United States)

    Rinehart, Stephen

    2011-01-01

    While infrared astronomy has revolutionized our understanding of galaxies, stars, and planets, further progress on major questions is stymied by the inescapable fact that the spatial resolution of single-aperture telescopes degrades at long wavelengths. The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-meter boom interferometer to operate in the FIR (30-90 micron) on a high altitude balloon. The long baseline will provide unprecedented angular resolution (approx. 5") in this band. In order for BETTII to be successful, the gondola must be designed carefully to provide a high level of stability with optics designed to send a collimated beam into the cryogenic instrument. We present results from the first 5 months of design effort for BETTII. Over this short period of time, we have made significant progress and are on track to complete the design of BETTII during this year.

  10. Stabilization of ballooning modes with sheared toroidal rotation

    International Nuclear Information System (INIS)

    A new code demonstrates the stabilization of MHD ballooning modes by sheared toroidal rotation. A shifted-circle model is used to elucidate the physics, and numerically reconstructed equilibria are used to analyze DIII-D discharges. In the ballooning representation, the modes shift periodically along the field line to the next point of unfavorable curvature. The shift frequency (dΩ/dq, where Ω is the angular toroidal velocity and q is the safety factor) is proportional to the rotation shear and inversely proportional to the magnetic shear. Stability improves with increasing shift frequency and, in the shifted circle model, direct stable access to the second stability regime occurs when this frequency is a fraction of the Alfven frequency, ωA = VA/qR. Shear stabilization is also demonstrated for an equilibrium reconstruction of a DIII-D VH-mode. (author). 9 refs, 3 figs

  11. Developing International Standards for Meteorological Balloon to Facilitate Industrial Progress

    Institute of Scientific and Technical Information of China (English)

    Deng Yizhi

    2011-01-01

    Meteorological balloon is made of natural rubber latex with a special process.On natural conditions,it carries the air sounding instrument into the high air to detect the meteorological elements in the air.As a means of delivery used in the aerological sounding,it is widely used in the meteorological,sailing,aeronautical,aerospace and other fields,and plays an extremely important role in the weather report,disaster prevention,disaster relief,guaranteeing ships and aircrafts to leave ports safely,and scientific research in relevant spaces,etc.Especially,the role of meteorological balloons is not ignorable in the forecast of extremely adverse weather frequently occurring around the world in recent years.

  12. [Adherence and fidelity in patients treated with intragastric balloon].

    Science.gov (United States)

    Mazure, R A; Cancer, E; Martínez Olmos, M A; De Castro, M L; Abilés, V; Abilés, J; Bretón, I; Álvarez, V; Peláez, N; Culebras, J M

    2014-01-01

    A correct treatment of obesity needs a program of habits modification regardless of the selected technique, especially if it is minimally invasive as the intragastric balloon (BIG). The adherence of the obese patients with regard to recommended drugs measures to medium- and long-term is less than 50%. Given that the results obtained using the technique of gastric balloon must be seen influenced by adherence to the modification of habits program and its fulfillment, we reviewed series published in attention to the program proposed with the BIG. The series published to date provide few details about the used Therapeutic Programs as well as the adherence of patients to them, and even less concerning the Monitoring Plan and the loyalty of the patient can be seen. We conclude the convenience to agree on a follow-up strategy, at least the 6 months during which the BIG remain in the stomach. PMID:24483961

  13. Electrodynamics of the stratosphere using 5000 cu m superpressure balloons

    Science.gov (United States)

    Holzworth, R. H.

    1983-01-01

    The Electrodynamics of the Middle Atmosphere research project encompasses the design of a microprocessor-controlled payload and the launch of up to eight small superpressure balloons in the 1982-1984 period. The primary payload instrument will measure the vector electric field from dc to 10 kHz, and the payloads will include instruments measuring local ionization, electrical conductivity, magnetic field, and temperature and pressure fluctuations. In addition, optical lightning will be recorded. The simultaneous measurement of these stratospheric parameters by several balloons, for periods extending over several solar rotations, will allow the study of electrical coupling between atmosphere and magnetosphere, of global current systems, and of global response to solar flares and magnetospheric storms.

  14. NEW APPROACHES: A hot air balloon from dustbin liners

    Science.gov (United States)

    Weaver, Nicholas

    1998-07-01

    This article describes how a simple hot air balloon, inflated by a hair dryer, can be made out of household bin liners and Sellotape. It can be used at sixth-form level as an application of the ideal gas equation, = constant, and is rather more exciting than heated pistons. It gives a taste of a simple engineering design process, although the students do have to be reasonably adept at geometry and algebra.

  15. Intraaortic Balloon Pump Counterpulsation and Cerebral Autoregulation: an observational study

    OpenAIRE

    Boots Rob; Barnett Adrian G; Timms Daniel; Dunster Kimble; Geng Shureng; Bellapart Judith; Fraser John F

    2010-01-01

    Abstract Background The use of Intra-aortic counterpulsation is a well established supportive therapy for patients in cardiac failure or after cardiac surgery. Blood pressure variations induced by counterpulsation are transmitted to the cerebral arteries, challenging cerebral autoregulatory mechanisms in order to maintain a stable cerebral blood flow. This study aims to assess the effects on cerebral autoregulation and variability of cerebral blood flow due to intra-aortic balloon pump and in...

  16. Double-balloon enteroscopy in detecting small intestinal bleeding

    Institute of Scientific and Technical Information of China (English)

    ZHI Fa-chao; PAN De-shou; ZHOU Dian-yuan; XIAO Bing; JIANG Bo; WAN Tian-mo; GUO Yu; ZHOU Dan; WANG Li-hui; CHEN Jin-feng; XIE Lu

    2005-01-01

    @@ Digestive tract hemorrhage is a common disease of the digestive system, but about 0.4%-5% intestinal bleeding can not be detected with gastroscope or colonscope.1 Since the intestine is long, tortuous, far away from both ends of the digestive tract and unfixed in position, clinical diagnosis of the bleeding is relatively difficult. Yamamoto and Sugano2 reported the clinical application of double-balloon enteroscope at American DDW in 2003.

  17. Effect of Externally Driven Magnetic Islands on Resistive Ballooning Turbulence

    OpenAIRE

    NISHIMURA, Seiya; Yagi, Masatoshi

    2011-01-01

    Turbulent transport in the edge region of tokamak plasmas is simulated using a reduced set of magnetohydrodynamic equations. Repetitive and intermittent transport bursts driven by resistive ballooning turbulence with external heating are observed. The effect of a resonant magnetic perturbation (RMP) on turbulent heat transport is examined, where the electromagnetic response of the plasma to the RMP is solved consistently. The penetration of the RMP excites a magnetic island chain and damps th...

  18. Balloon Kyphoplasty: An Effective Treatment for Kummell Disease?

    Science.gov (United States)

    Kim, Pius

    2016-01-01

    Objective The purpose of this study was to evaluate the efficacy of balloon kyphoplasty for treating Kummel disease accompanying severe osteoporosis. Methods Twelve patients with single-level Kummell disease accompanied by severe osteoporosis were enrolled in this investigation. After postural reduction for 1 or 2 days, balloon kyphoplasty was performed on the collapsed vertebrae. Clinical results, radiological parameters, and related complications were assessed at 7 days, 1 month and 6 months after the procedure. Results Prior to kyphoplasty, the mean pain score (according to the visual analogue scale) was 8.0. Seven days after the procedure, this score improved to 2.5. Despite the significant improvement compared to preoperative value, the score increased to 4.0 at 6 months after the procedure. The mean preoperative vertebral height loss was 55.4%. Kyphoplasty reduced this loss to 31.6%, but it increased to 38.7% at 6 months after the procedure. The kyphotic angle improved significantly from 22.4°±4.9° (before the procedure) to 10.1°±3.8° after surgery, However, the improved angle was not maintained 6 months after the procedure. The mean correction loss for the kyphotic deformity was 7.2° at 6 months after the procedure. Three out of 12 patients sustained adjacent fractures after balloon kyphoplasty within 6 months. Conclusion Although balloon kyphoplasty for treating Kummell disease is known to provide stabilization and pain relief, it may be associated with the development of adjacent fractures and aggravated kyphosis. PMID:27799987

  19. Latex Micro-balloon Pumping in Centrifugal Microfluidic Platforms

    OpenAIRE

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Al-Faqheri, Wisam; Thio, Tzer Hwai Gilbert; Kazemzadeh, Amin; Wadi harun, Sulaiman; Madou, Marc

    2014-01-01

    Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-stepped processes on a single microfluidics disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a...

  20. The Rocket Balloon (Rocketball): Applications to Science, Technology, and Education

    Science.gov (United States)

    Esper, Jaime

    2009-01-01

    Originally envisioned to study upper atmospheric phenomena, the Rocket Balloon system (or Rocketball for short) has utility in a range of applications, including sprite detection and in-situ measurements, near-space measurements and calibration correlation with orbital assets, hurricane observation and characterization, technology testing and validation, ground observation, and education. A salient feature includes the need to reach space and near-space within a critical time-frame and in adverse local meteorological conditions. It can also provide for the execution of technology validation and operational demonstrations at a fraction of the cost of a space flight. In particular, planetary entry probe proof-of-concepts can be examined. A typical Rocketball operational scenario consists of a sounding rocket launch and subsequent deployment of a balloon above a desired location. An obvious advantage of this combination is the additional mission 'hang-time' rendered by the balloon once the sounding rocket flight is completed. The system leverages current and emergent technologies at the NASA Goddard Space Flight Center and other organizations.

  1. A Sensitivity Analysis of fMRI Balloon Model

    KAUST Repository

    Zayane, Chadia

    2015-04-22

    Functional magnetic resonance imaging (fMRI) allows the mapping of the brain activation through measurements of the Blood Oxygenation Level Dependent (BOLD) contrast. The characterization of the pathway from the input stimulus to the output BOLD signal requires the selection of an adequate hemodynamic model and the satisfaction of some specific conditions while conducting the experiment and calibrating the model. This paper, focuses on the identifiability of the Balloon hemodynamic model. By identifiability, we mean the ability to estimate accurately the model parameters given the input and the output measurement. Previous studies of the Balloon model have somehow added knowledge either by choosing prior distributions for the parameters, freezing some of them, or looking for the solution as a projection on a natural basis of some vector space. In these studies, the identification was generally assessed using event-related paradigms. This paper justifies the reasons behind the need of adding knowledge, choosing certain paradigms, and completing the few existing identifiability studies through a global sensitivity analysis of the Balloon model in the case of blocked design experiment.

  2. The balloon-borne electron telescope with scintillating fibers (BETS)

    CERN Document Server

    Torii, S; Tateyama, N; Yoshida, K; Ouchi, Y; Yamagami, T; Saitô, Y; Murakami, H; Kobayashi, T; Komori, Y; Kasahara, K; Yuda, T; Nishimura, J

    2000-01-01

    we describe a new detector system developed for high-altitude balloon flights to observe the cosmic-ray electrons above 10 GeV. The balloon borne electron telescope with Scintillating (BETS) fibers instrument is an imaging calorimeter which is capable of selecting electrons against the large background of protons. The calorimeter is composed of a sandwich of scintillating optical-fiber belts and lead plates with a combination of three plastic scintillators for the shower trigger. The total thickness of lead is 40 mm (~7.1 r.l.) and the number of fiber belts is nine. In each belt, alternating layers are oriented in orthogonal (x and y) directions. Two sets of an intensified CCD camera are adopted for read-out of the scintillating fibers in the x and y direction, respectively. The accelerator beam tests were carried out to study the performance of detector for electrons in 1996 and for protons in 1997 at CERN-SPS. The instrument was successfully flown aboard high-altitude balloon in 1997 and 1998. It is demonst...

  3. Precision Attitude Control for the BETTII Balloon-Borne Interferometer

    Science.gov (United States)

    Benford, Dominic J.; Fixsen, Dale J.; Rinehart. Stephen

    2012-01-01

    The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-meter baseline far-infrared interferometer to fly on a high altitude balloon. Operating at wavelengths of 30-90 microns, BETTII will obtain spatial and spectral information on science targets at angular resolutions down to less than half an arcsecond, a capability unmatched by other far-infrared facilities. This requires attitude control at a level ofless than a tenth of an arcsecond, a great challenge for a lightweight balloon-borne system. We have designed a precision attitude determination system to provide gondola attitude knowledge at a level of 2 milliarcseconds at rates up to 100Hz, with accurate absolute attitude determination at the half arcsecond level at rates of up to 10Hz. A mUlti-stage control system involving rigid body motion and tip-tilt-piston correction provides precision pointing stability to the level required for the far-infrared instrument to perform its spatial/spectral interferometry in an open-loop control. We present key aspects of the design of the attitude determination and control and its development status.

  4. Inverted Meckel's diverticulum preoperatively diagnosed using double-balloon enteroscopy.

    Science.gov (United States)

    Takagaki, Kosuke; Osawa, Satoshi; Ito, Tatsuhiro; Iwaizumi, Moriya; Hamaya, Yasushi; Tsukui, Hiroe; Furuta, Takahisa; Wada, Hidetoshi; Baba, Satoshi; Sugimoto, Ken

    2016-05-01

    An inverted Meckel's diverticulum is a rare gastrointestinal congenital anomaly that is difficult to diagnose prior to surgery and presents with anemia, abdominal pain, or intussusception. Here, we report the case of 57-year-old men with an inverted Meckel's diverticulum, who was preoperatively diagnosed using double-balloon enteroscopy. He had repeatedly experienced epigastric pain for 2 mo. Ultrasonography and computed tomography showed intestinal wall thickening in the pelvis. Double-balloon enteroscopy via the anal route was performed for further examination, which demonstrated an approximately 8-cm, sausage-shaped, submucosal tumor located approximately 80 cm proximal to the ileocecal valve. A small depressed erosion was observed at the tip of this lesion. Forceps biopsy revealed heterotopic gastric mucosa. Thus, the patient was diagnosed with an inverted Meckel's diverticulum, and single-incision laparoscopic surgery was performed. This case suggests that an inverted Meckel's diverticulum should be considered as a differential diagnosis for a submucosal tumor in the ileum. Balloon-assisted enteroscopy with forceps biopsy facilitate a precise diagnosis of this condition. PMID:27158212

  5. A Low Cost Weather Balloon Borne Solar Cell Calibration Payload

    Science.gov (United States)

    Snyder, David B.; Wolford, David S.

    2012-01-01

    Calibration of standard sets of solar cell sub-cells is an important step to laboratory verification of on-orbit performance of new solar cell technologies. This paper, looks at the potential capabilities of a lightweight weather balloon payload for solar cell calibration. A 1500 gr latex weather balloon can lift a 2.7 kg payload to over 100,000 ft altitude, above 99% of the atmosphere. Data taken between atmospheric pressures of about 30 to 15 mbar may be extrapolated via the Langley Plot method to 0 mbar, i.e. AMO. This extrapolation, in principle, can have better than 0.1 % error. The launch costs of such a payload arc significantly less than the much larger, higher altitude balloons, or the manned flight facility. The low cost enables a risk tolerant approach to payload development. Demonstration of 1% standard deviation flight-to-flight variation is the goal of this project. This paper describes the initial concept of solar cell calibration payload, and reports initial test flight results. .

  6. Balloon Cell Urethral Melanoma: Differential Diagnosis and Management

    Directory of Open Access Journals (Sweden)

    M. McComiskey

    2015-01-01

    Full Text Available Introduction. Primary malignant melanoma of the urethra is a rare tumour (0.2% of all melanomas that most commonly affects the meatus and distal urethra and is three times more common in women than men. Case. A 76-year-old lady presented with vaginal pain and discharge. On examination, a 4 cm mass was noted in the vagina and biopsy confirmed melanoma of a balloon type. Preoperative CT showed no distant metastases and an MRI scan of the pelvis demonstrated no associated lymphadenopathy. She underwent anterior exenterative surgery and vaginectomy also. Histology confirmed a urethral nodular malignant melanoma. Discussion. First-line treatment of melanoma is often surgical. Adjuvant treatment including chemotherapy, radiotherapy, or immunotherapy has also been reported. Even with aggressive management, malignant melanoma of the urogenital tract generally has a poor prognosis. Recurrence rates are high and the mean period between diagnosis and recurrence is 12.5 months. A 5-year survival rate of less than 20% has been reported in balloon cell melanomas along with nearly 20% developing local recurrence. Conclusion. To the best of our knowledge, this case is the first report of balloon cell melanoma arising in the urethra. The presentation and surgical management has been described and a literature review provided.

  7. The exposure of radiologists and patients to radiation during coronary angiography and percutaneous transluminal coronary angioplasty (PTCA)

    International Nuclear Information System (INIS)

    The exposure of radiologists and patients to radiation during coronary angiography and percutaneous transluminal coronary angioplasty (PTCA) in Finland was studied using phantom measurements. Additional tests were made concerning the performance of TV fluoroscopy systems, cine fluorographic units and film processing. These tests include sensitometric quality control of film processing, automatic exposure control in fluoroscopy and cinefluorography, and contrast and resolution in a cine frame and TV image

  8. Gore-Tex small-vessel angioplasty: A suitable substitute for the use of autogenous saphenous vein grafts

    OpenAIRE

    Garcia-Rinaldi, Raul; Rea, John E.; Gallagher, Michael W.; Laevsky, Marlene J.; Ogburn, Michael; Porter, Robert H.

    1980-01-01

    Autogenous saphenous vein has been the material of choice for small-vessel angioplasty and for circulatory access graft reconstruction. In an effort to conserve autogenous saphenous vein, we used expanded polytetrafluoroethylene (PTFE) grafts in 45 patients over a 12-month period. We used Gore-Tex* to reconstruct 17 circulatory access grafts, 16 carotid arteries, two brachial arteries, seven femoral arteries, and three popliteal anterior or posterior tibial arteries. The indications for recon...

  9. Percutaneous transluminal angioplasty in a patient with internal carotid artery stenosis following gamma knife radiosurgery for recurrent pituitary adenoma

    OpenAIRE

    Hidemichi Ito; Hidetaka Onodera; Taigen Sase; Masashi Uchida; Hiroyuki Morishima; Kotaro Oshio; Takashi Shuto; Yuichiro Tanaka

    2015-01-01

    Background: Intracranial vascular complications following radiosurgery are extremely rare. Case Description: We report a case of stenosis in the internal carotid artery 5 years after gamma knife radiosurgery for a recurrent pituitary adenoma. Percutaneous transluminal angioplasty was performed successfully with anatomical and functional improvement. Conclusion: These results suggested the importance of monitoring for arterial stenosis in the long-term follow-up. Moreover, this is the ...

  10. [Dextrocardia in situs inversus totalis with obstructive coronary disease. Its treatment by coronary angioplasty by the brachial approach].

    Science.gov (United States)

    da Silva, M J; Arie, S; Garcia, D P; Bellotti, G; Pileggi, F

    1992-10-01

    Dextrocardia in "situs inversus totalis" with obstructive coronary disease is a rare clinical situation, with few cases treated by coronary angioplasty using the femoral approach being reported. In this report we describe the case of a 61-year-old male patient who underwent successful dilatation of two arteries by the brachial approach. We discuss technical aspects related to the procedure, which may be easily performed when proper equipment is available.

  11. Safety and efficacy of angioplasty with intracoronary stenting in patients with unstable coronary syndromes. Comparison with stable coronary syndromes

    Directory of Open Access Journals (Sweden)

    Luís C. L. Correia

    2000-06-01

    Full Text Available OBJECTIVE: To assess safety and efficacy of coronary angioplasty with stent implantation in unstable coronary syndromes. METHODS: Retrospective analysis of in-hospital and late evolution of 74 patients with unstable coronary syndromes (unstable angina or infarction without elevation of the ST segment undergoing coronary angioplasty with stent placement. These 74 patients were compared with 31 patients with stable coronary syndromes (stable angina or stable silent ischemia undergoing the same procedure. RESULTS: No death and no need for revascularization of the culprit artery occurred in the in-hospital phase. The incidences of acute non-Q-wave myocardial infarction were 1.4% and 3.2% (p=0.6 in the unstable and stable coronary syndrome groups, respectively. In the late follow-up (11.2±7.5 months, the incidences of these events combined were 5.7% in the unstable coronary syndrome group and 6.9% (p=0.8 in the stable coronary syndrome group. In the multivariate analysis, the only variable with a tendency to significance as an event predictor was diabetes mellitus (p=0.07; OR=5.2; 95% CI=0.9-29.9. CONCLUSION: The in-hospital and late evolutions of patients with unstable coronary syndrome undergoing angioplasty with intracoronary stent implantation are similar to those of the stable coronary syndrome group, suggesting that this procedure is safe and efficacious when performed in unstable coronary syndrome patients.

  12. Effects of Endovascular Brachytherapy with 192Ir Afterloading System on Expression of Type Ⅰ Collagen after Angioplasty

    Institute of Scientific and Technical Information of China (English)

    向定成; 杨传红; 候友贤; 龚志华; 易绍东; 邱建

    2003-01-01

    Objectives To investi-gate the effect and mechanism of endovascularbrachytherapy with 192Ir on expression of type Ⅰ collagen, metalloproteinases - 1 (MMP - 1) and the tissueinhibitor (TIMP- 1 ) after angioplasty. MethodsRestenotic model of domestic microswine was em-ployed and the iliac arteries were randomized to radi-ation group ( n = 12), which were treated with 20 ~ 25Gy of 192Ir, and non - radiation group ( n = 36) afterangioplasty. The target vessels were harvested in theend of 3 months and 6 months after angioplasty. Im-munohistochemistry and in situ hybridization were usedto detect proteins of type Ⅰ collagen, MMP-1 andTIMP- 1, and mRNA expression of type Ⅰ collagen.Results The protein and mRNA of type Ⅰ collagen,the ratios of TIMP-1/MMP-1 were significantlylower iu radiation group than in non- radiation group( P < 0.05 or 0.01 ). The peak of transcription of typeⅠ collagen mRNA was at 6 months and 3 months in non-radiation group and radiation group respectively.Conclusions Endovascular brachytherapy with192Ir might modify the metabolism of extracellular ma-trix after angioplasty by inhibiting the synthesis of typeⅠ collagen and the activities of MMP - 1 and TIMP - 1.

  13. Same-day discharge after angioplasty for peripheral vascular disease: is it a safe and feasible option?

    Science.gov (United States)

    Maher, Paula

    2014-09-01

    Peripheral vascular disease affects 20% of the population >55 years of age. Patients who become symptomatic are managed by a number of technique's including medical management, percutaneous angioplasty, bypass surgery, and in nonreconstructable situations, limb amputation. Clinicians treating patients by means of angioplasty have traditionally carried out these procedures on an inpatient basis. Limited resources and pressure on the availability of inpatient beds has necessitated clinicians to reevaluate how many of these patients are managed. Treating suitable patients as day cases is an attractive option that frees up resources and is financially advantageous. This paper examines the feasibility of same-day discharge after angioplasty, with a particular emphasis on achieving safe patient outcomes. It explores how advances in endovascular technologies and techniques have contributed to making same-day discharge an ever more feasible option. Nurse led pre-admission clinics run by specialist nurses facilitate safe and appropriate patient selection, where patients at risk for postprocedural problems can be identified effectively based on predefined clinical criteria.

  14. Early clinical outcome and complications related to balloon kyphoplasty

    Directory of Open Access Journals (Sweden)

    Martin Bergmann

    2012-06-01

    Full Text Available The treatment of painful osteoporotic vertebral compression fractures using transpedicular cement augmentation has grown significantly over the last two decades. The benefits of balloon kyphoplasty compared to conservative treatment remain controversial and are discussed in the literature. The complication rates of vertebroplasty and kyphoplasty are considered to be low. The focus of this study was the analysis of acute and clinically relevant complications related to this procedure. In our department, all patients treated between February 2002 and February 2011 with percutaneous cement augmentation (372 patients, 522 augmented vertebral bodies were prospectively recorded. Demographic data, comorbidities, fracture types, intraoperative data and all complications were documented. The pre- and postoperative pain-level and neurological status (Frankel-Score were evaluated. All patients underwent a standardized surgical procedure. Two hundred and ninety-seven patients were treated solely by balloon kyphoplasty; 216 females (72.7% and 81 males (27.3%. Average patient age was 76.21 years (±10.71, range 35-98 years. Average American Society Anestesiologists score was 3.02. According to the Orthopedic Trauma Association classification, there were 69 A 1.1 fractures, 177 A 1.2 fractures, 178 A 3.1.1 fractures and 3 A 3.1.3 fractures. Complications were divided into preoperative, intraoperative and postoperative events. There were 4 pre-operative complications: 3 patients experienced persistent pain after the procedure. In one case, the pedicles could not be visualized during the procedure and the surgery was terminated. One hundred and twenty-nine (40.06% of the patients showed intraoperative cement leaking outside the vertebras, one severe hypotension and tachycardia as reaction to the inflation of the balloons, and there was one cardiac arrest during surgery. Postoperative subcutaneous hematomas were observed in 3 cases, 13 patients developed a

  15. Planetary Balloon-Based Science Platform Evaluation and Program Implementation

    Science.gov (United States)

    Dankanich, John W.; Kremic, Tibor; Hibbitts, Karl; Young, Eliot F.; Landis, Rob

    2016-01-01

    This report describes a study evaluating the potential for a balloon-based optical telescope as a planetary science asset to achieve decadal class science. The study considered potential science achievable and science traceability relative to the most recent planetary science decadal survey, potential platform features, and demonstration flights in the evaluation process. Science Potential and Benefits: This study confirms the cost the-benefit value for planetary science purposes. Forty-four (44) important questions of the decadal survey are at least partially addressable through balloon based capabilities. Planetary science through balloon observations can provide significant science through observations in the 300 nm to 5 m range and at longer wavelengths as well. Additionally, balloon missions have demonstrated the ability to progress from concept to observation to publication much faster than a space mission increasing the speed of science return. Planetary science from a balloon-borne platform is a relatively low-cost approach to new science measurements. This is particularly relevant within a cost-constrained planetary science budget. Repeated flights further reduce the cost of the per unit science data. Such flights offer observing time at a very competitive cost. Another advantage for planetary scientists is that a dedicated asset could provide significant new viewing opportunities not possible from the ground and allow unprecedented access to observations that cannot be realized with the time allocation pressures faced by current observing assets. In addition, flight systems that have a relatively short life cycle and where hardware is generally recovered, are excellent opportunities to train early career scientists, engineers, and project managers. The fact that balloon-borne payloads, unlike space missions, are generally recovered offers an excellent tool to test and mature instruments and other space craft systems. Desired Gondola Features: Potential

  16. Intestinal cholesterol embolism resulting from intra-aortic balloon pumping: a case report

    OpenAIRE

    Yamaguchi, Satoshi; Kakazu, Masanori; Osamu, Arasaki

    2014-01-01

    Introduction Intra-aortic balloon pumping is used in elective percutaneous coronary intervention for increasing coronary blood flow. However, intra-aortic balloon pumping may decrease visceral blood flow and cause mesenteric ischemia by visceral artery obstruction. Case presentation We report the case of a 79-year-old Asian man in whom elective percutaneous coronary intervention was performed with intra-aortic balloon pumping. He died from mesenteric ischemia 25 hours after the procedure. Mic...

  17. Gene Therapy for the Prevention of in- Stent Restenosis Post Coronary Angioplasty

    Directory of Open Access Journals (Sweden)

    P Ranjzad

    2005-10-01

    Full Text Available Around the world, Coronary Artery Disease (CAD is quickly becoming the most common cause of morbidity and mortality. Percutaneous coronary interventions- angioplasty and stent insertion- have proved effective and reliable treatments for CAD but their long-term efficacy is limited by the high rate of restenosis. This occurs in 30 – 50% of patients undergoing angioplasty and results in symptoms requiring repeat intervention in up to 75% of them. Stent insertion has been shown to reduce this rate but in-stent restenosis still occurs in 20-40% of cases. The high incidence of restenosis represents a large economic burden on health resources. As a consequence of the resistance of restenosis to traditional therapeutic approaches, gene therapy has emerged an attractive potential therapy for this problem. Excessive extracellular matrix (ECM deposition in the neointima is the main mechanism leading to luminal loss after coronary stenting. Transforming growth factor-β (TGF-β is a major regulator of ECM deposition and there is substantial evidence to suggest its role in restenosis. TGF-β1 is the predominant isoform in vascular tissues and its production is observed to be upregulated in human restenotic lesions and in the intima of injured animal vessels. The aim of this study is to develop, investigate and compare the effects of two potentially therapeutic recombinant, replication-deficient adenoviruses, which will give rise to the expression of transgenic proteins which antagonise the fibrogenic effects of TGF-β1 in coronary arteries post stent insertion. The cDNA for these proteins have each been inserted into replication deficient adenovirus vectors under the control of the Major Immediate/Early Murine Cytomegalovirus (MIEmCMV promoter. Virus identity and the presence of transgenes have been confirmed by restriction analysis and Southern blotting respectively. Efficient transgene expression has been confirmed in cultured porcine coronary vascular

  18. High-Altitude Ballooning Program at the Indian Institute of Astrophysics

    CERN Document Server

    Nayak, A; Safonova, M; Murthy, Jayant

    2013-01-01

    We have begun a program of high altitude ballooning at the Indian Institute of Astrophysics, Bangalore. Recent advances in balloons as well as in electronics have made possible scientific payloads at costs accessible to university departments. The primary purpose of this activity is to test low-cost ultraviolet (UV) payloads for eventual space flight, but to also explore phenomena occurring in the upper atmosphere, including sprites and meteorite impacts, using balloon-borne payloads. This paper discusses the results of three tethered balloon experiments carried out at the CREST campus of IIA, Hosakote and our plans for the future. We also describe the stages of payload development for these experiments.

  19. Development of ultra-thin polyethylene balloons for high altitude research upto mesosphere

    CERN Document Server

    Kumar, B Suneel; Ojha, D K; Peter, G Stalin; Vasudevan, R; Anand, D; Kulkarni, P M; Reddy, V Anmi; Rao, T V; Sreenivasan, S

    2014-01-01

    Ever since its inception four decades back, Balloon Facility of Tata Institute of Fundamental Research (TIFR), Hyderabad has been functioning with the needs of its user scientists at its focus. During the early nineties, when the X-ray astronomy group at TIFR expressed the need for balloons capable of carrying the X-ray telescopes to altitudes up to 42 km, the balloon group initiated research and development work on indigenous balloon grade films in various thickness not only for the main experiment but also in parallel, took up the development of thin films in thickness range 5 to 6 microns for fabrication of sounding balloons required for probing the stratosphere up to 42 km as the regular 2000 grams rubber balloon ascents could not reach altitudes higher than 38 km. By the year 1999, total indigenisation of sounding balloon manufacture was accomplished. The work on balloon grade ultra-thin polyethylene film in thickness range 2.8 to 3.8 microns for fabrication of balloons capable of penetrating mesosphere ...

  20. Thromboembolic events associated with single balloon-, double balloon-, and stent-assisted coil embolization of asymptomatic unruptured cerebral aneurysms: evaluation with diffusion-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takigawa, Tomoji; Suzuki, Kensuke; Sugiura, Yoshiki; Suzuki, Ryotaro; Takano, Issei; Shimizu, Nobuyuki; Tanaka, Yoshihiro; Hyodo, Akio [Dokkyo Medical University Koshigaya Hospital, Department of Neurosurgery, Koshigaya, Saitama (Japan)

    2014-12-15

    The introduction of the balloon remodeling and stent-assisted technique has revolutionized the approach to coil embolization for wide-neck aneurysms. The purpose of this study was to determine the frequency of thromboembolic events associated with single balloon-assisted, double balloon-assisted, and stent-assisted coil embolization for asymptomatic unruptured aneurysms. A retrospective review was undertaken by 119 patients undergoing coiling with an adjunctive technique for unruptured saccular aneurysms (64 single balloon, 12 double balloon, 43 stent assisted). All underwent diffusion-weighted imaging (DWI) within 24 h after the procedure. DWI showed hyperintense lesions in 48 (40 %) patients, and ten (21 %) of these patients incurred neurological deterioration (permanent, two; transient, eight). Hyperintense lesions were detected significantly more often in procedures with the double balloon-assisted technique (7/12, 58 %) than with the single balloon-assisted technique (16/64, 25 %, p = 0.05). Occurrence of new lesions was significantly higher with the use of stent-assisted technique (25/43, 58 %) than with the single balloon-assisted technique (p = 0.001). Symptomatic ischemic rates were similar between the three groups. The increased number of microcatheters was significantly related to the DWI abnormalities (two microcatheters, 15/63 (23.8 %); three microcatheters, 20/41 (48.8 %) (p = 0.008); four microcatheters, 12/15 (80 %) (p = 0.001)). Thromboembolic events detected on DWI related to coil embolization for unruptured aneurysms are relatively common, especially in association with the double balloon-assisted and stent-assisted techniques. Furthermore, the number of microcatheters is highly correlated with DWI abnormalities. The high rate of thromboembolic events suggests the need for evaluation of platelet reactivity and the addition or change of antiplatelet agents. (orig.)

  1. Outcomes of Percutaneous Management of Anastomotic Ureteral Strictures in Renal Transplantation: Chronic Nephroureteral Stent Placement with and without Balloon Dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Uflacker, A., E-mail: andreuflacker@gmail.com; Sheeran, D., E-mail: dsheeran9@gmail.com; Khaja, M., E-mail: mkhaja@mac.com [University of Virginia/Interventional Radiology (United States); Patrie, J., E-mail: jp4h@virginia.edu [UVA Health System/Radiology (United States); Elias, G., E-mail: gae2y@virginia.edu [VCU Medical Center/Radiology (United States); Saad, W., E-mail: wspikes@yahoo.com [University of Michigan Health System (United States)

    2015-06-15

    PurposeThis study was designed o evaluate outcomes of percutaneous management of anastomotic ureteral strictures in renal transplants using nephroureteral stents with or without balloon dilatation.MethodsA retrospective audit of 1,029 consecutive renal transplants was performed. Anastomotic ureteral strictures were divided into two groups: nephroureteral stent only (NUS) and NUS+PTA (nephroureteral stent plus percutaneous transluminal angioplasty), with each cohort subdivided into early versus late presentation (obstructive uropathy occurring <90 day or >90 days from transplant, respectively). Overall and 6-month technical success were defined as removal of NUS any time with <30 % residual stenosis (any time lapse less or more than 6 months) and at >6 months, respectively. Patency was evaluated from NUS removal to last follow-up for both groups and compared.ResultsSixty-seven transplant patients with 70 ureteric anastomotic strictures (6.8 %, n = 70/1,029) underwent 72 percutaneous treatments. 34 % were late (>90 days, n = 24/70), and 66 % were early (<90 days, n = 46/70). Overall technical success was 82 % (n = 59/72) and 6-month success was 58 % (n = 42/72). Major and minor complications were 2.8 % (n = 2/72), and 12.5 % (n = 9/72). NUS+PTA did not improve graft survival (p = 0.354) or patency (p = 0.9) compared with NUS alone. There was no difference in graft survival between treated and nontreated groups (p = 0.74).ConclusionsThere is no advantage to PTA in addition to placement of NUS, although PTA did not negatively impact graft survival or long-term patency and both interventions were safe and effective. Neither the late or early groups benefited from PTA in addition to NUS. Earlier obstructions showed greater improvement in serum creatinine than later obstructions.

  2. Experimental investigation of undesired stable equilibria in pumpkin shape super-pressure balloon designs

    Science.gov (United States)

    Schur, W.

    The scientific community's desire for large capacity, constant altitude, long duration stratospheric platforms is not likely going to be met by un-reinforced spherical super-pressure balloons. More likely, the pneumatic envelope for the large-scale super-pressure balloon of the future will be a tendon reinforced structure in which the tendons perform the primary pressure load confining function and the skin serves as a gas barrier and transfers the local pressure load to the tendons. NASA's Ultra Long Duration Balloon (ULDB), which is currently under development, is of that type. By separating the load carrying function of the tendons and the skin a number of advantages are gained. Perhaps most important is the fact that the required skin strength remains to first order independent of the balloon size. Only the size and number of tendons are dictated by the balloon size. By designing the balloon to be at least quasi statically determinate, the stress distributions are more certain, and stress raisers due to fabrication imperfections are more easily controlled and it becomes unnecessary to account for load path uncertainties by providing everywhere excessive strength and structural weight. Furthermore, it becomes possible to use for the envelope skin a visco-elastic film (polyethylene) that has proven performance in the stratospheric environment. The silhouette shape of this balloon type has prompted early researchers to name this design a "pumpkin" shape balloon. Later investigators accepted this terminology. The pumpkin shape balloon concept was adopted by NASA for its ULDB design at the end of 1998 when advantages of that design over a spherical shape design were convincingly demonstrated. Two stratospheric test flights of large-scale super-pressure balloons demonstrated the functioning of this balloon type. In the second successful flight the switch was made from an excessively strong and heavy skin, a holdover from the earlier concept of a spherical design, to

  3. Below knee angioplasty in elderly patients: Predictors of major adverse clinical outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Keeling, Aoife N.; Khalidi, Karim; Leong, Sum [Department of Academic Radiology, Beaumont Hospital, Beaumont Road, Dublin 9 (Ireland); Wang, Tim T. [Department of Biosurgery and Surgical Technology, Imperial College London, St. Mary' s Hospital, London W2 1NY (United Kingdom); Ayyoub, Alaa S.; McGrath, Frank P. [Department of Academic Radiology, Beaumont Hospital, Beaumont Road, Dublin 9 (Ireland); Athanasiou, Thanos [Department of Biosurgery and Surgical Technology, Imperial College London, St. Mary' s Hospital, London W2 1NY (United Kingdom); Lee, Michael J., E-mail: mlee@rcsi.ie [Department of Academic Radiology, Beaumont Hospital, Beaumont Road, Dublin 9 (Ireland)

    2011-03-15

    Aim: To determine predictors of clinical outcome following percutaneous transluminal angioplasty (PTA) in elderly patients with below knee atherosclerotic lesions causing intermittent claudication (IC) or critical limb ischaemia (CLI). Materials and methods: Over 7.5 years, 76 patients (CLI 72%, n = 55) underwent below knee PTA. The composite end-point of interest was major adverse clinical outcome (MACO) of the treated limb at follow-up which was defined as clinical failure, need for subsequent endovascular or surgical revascularization or amputation. Actuarial freedom from MACO was assessed using Kaplan-Meier curves and multivariable Cox proportional hazards regression. Results: IC was improved in 95% at mean 3.4 years (range 0.5-108 months). Successful limb salvage and ulcer healing were seen in 73% with CLI. Most failures were in the CLI group (27% CLI vs. 5% IC), with an amputation rate of 16% for CLI vs. 5% for IC and persistent ulceration in 24% of CLI. Significant independent predictors of MACO were ulceration (hazard ratio 4.02, 95% CI = 1.55-10.38) and family history of atherosclerosis (hazard ratio 2.53, 95% CI = 1.1-5.92). Conclusion: Primary below knee PTA is a feasible therapeutic option in this elderly population. Limb ulceration and family history of atherosclerosis may be independent predictors of adverse outcome.

  4. Femoral versus Radial Access in Primary Angioplasty. Analysis of the ACCEPT Registry

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Pedro Beraldo de, E-mail: pedroberaldo@cardiol.br; Andrade, Mônica Vieira Athanazio de; Barbosa, Robson Alves; Labrunie, André [Santa Casa de Misericórdia de Marília, São Paulo -SP (Brazil); Hernandes, Mauro Esteves [Santa Casa de Votuporanga, São Paulo -SP (Brazil); Marino, Roberto Luiz [Hospital Madre Teresa, Belo Horizonte -MG (Brazil); Precoma, Dalton Bertolim [Sociedade Hospital Angelina Caron, Campina Grande do Sul -PR (Brazil); Sá, Francisco Carleial Feijó de [Hospital do Coração do Cariri, Barbalha -CE (Brazil); Berwanger, Otávio [Instituto de Ensino e Pesquisa do Hospital do Coração, São Paulo -SP (Brazil); Mattos, Luiz Alberto Piva e [Sociedade Brasileira de Cardiologia, São Paulo -SP (Brazil); Instituto Dante Pazzanese de Cardiologia, São Paulo -SP (Brazil); Unidades de Hemodinâmica e Intervenção Cardiovascular Rede D' Or / São Luiz, São Paulo, SP (Brazil)

    2014-06-15

    The radial access provides a lower risk of bleeding and vascular complications related to the puncture site in comparison to the femoral access. Recent studies have suggested a reduction in mortality associated with the radial access in patients with acute myocardial infarction undergoing percutaneous coronary intervention. To compare the occurrence of adverse cardiovascular ischemic and hemorrhagic events in patients undergoing primary angioplasty according to the type of arterial access route. From August 2010 to December 2011, 588 patients undergoing primary percutaneous coronary intervention during acute ST-segment elevation myocardial infarction were assessed; they were recruited from 47 centers participating in the ACCEPT registry. Patients were grouped and compared according to the arterial access used for the procedure. The mean age was 61.8 years; 75% were males and 24% had diabetes mellitus. There was no difference between groups as regards the procedure success rate, as well as regards the occurrence of death, reinfarction, or stroke at six months of follow-up. Severe bleeding was reported in 1.1% of the sample analyzed, with no statistical difference related to the access used. The femoral and radial accesses are equally safe and effective for the performance of primary percutaneous coronary intervention. The low rate of cardiovascular events and of hemorrhagic complications reflects the quality of the participating centers and the operators expertise with the use of both techniques.

  5. Carotid angioplasty with stenting for chronic internal carotid artery occlusion: technical note

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Nozomu; Tanasawa, Toshihiko; Okada, Takeshi; Endo, Otone; Yamamoto, Naohito [Kainan Hospital Aichi Prefectural Welfare Federation of Agricultural Cooperatives, Department of Neurosurgery, Aichi (Japan); Miyachi, Shigeru; Hattori, Kenichi [Nagoya University Graduate School of Medicine, Department of Neurosurgery, Nagoya (Japan)

    2006-11-15

    Carotid angioplasty with stenting (CAS) is becoming accepted as an effective and reliable treatment option for severe carotid artery stenosis. However, it is rarely applied for carotid occlusion, especially in its chronic stage. We report our experience of CAS for chronic internal carotid artery occlusion representing compromised cerebral blood flow using various protection methods. A 77-year-old woman, who was already diagnosed with severe left internal carotid artery stenosis, suddenly had right hemiparesis and aphasia. At that time, she was treated conservatively because her neurological status was quite good, in spite of left carotid artery occlusion. Her symptoms improved in the short term, except slight aphasia, but deteriorated again 18 days from the onset, and magnetic resonance imaging (MRI) showed new ischemic lesions. CAS was then performed for the occluded carotid artery on the 23rd day from the first onset. Using the proximal protection technique, the occluded lesion was crossed carefully with a microguidewire. Stents were also placed successfully with the distal protection technique. The occluded carotid artery was completely recanalized without any unfavorable events or neurological deterioration. In this patient, CAS was successfully to treat chronic carotid artery occlusion. These procedures and techniques are reviewed and discussed. (orig.)

  6. Femoral versus Radial Access in Primary Angioplasty. Analysis of the ACCEPT Registry

    Directory of Open Access Journals (Sweden)

    Pedro Beraldo de Andrade

    2014-07-01

    Full Text Available Background: The radial access provides a lower risk of bleeding and vascular complications related to the puncture site in comparison to the femoral access. Recent studies have suggested a reduction in mortality associated with the radial access in patients with acute myocardial infarction undergoing percutaneous coronary intervention. Objective: To compare the occurrence of adverse cardiovascular ischemic and hemorrhagic events in patients undergoing primary angioplasty according to the type of arterial access route. Methods: From August 2010 to December 2011, 588 patients undergoing primary percutaneous coronary intervention during acute ST-segment elevation myocardial infarction were assessed; they were recruited from 47 centers participating in the ACCEPT registry. Patients were grouped and compared according to the arterial access used for the procedure. Results: The mean age was 61.8 years; 75% were males and 24% had diabetes mellitus. There was no difference between groups as regards the procedure success rate, as well as regards the occurrence of death, reinfarction, or stroke at six months of follow-up. Severe bleeding was reported in 1.1% of the sample analyzed, with no statistical difference related to the access used. Conclusions: The femoral and radial accesses are equally safe and effective for the performance of primary percutaneous coronary intervention. The low rate of cardiovascular events and of hemorrhagic complications reflects the quality of the participating centers and the operators expertise with the use of both techniques.

  7. Effect of Carvedilol on the Coronary Vascular Endothelial Function after Percutaneous Transluminal Coronary Angioplasty

    Institute of Scientific and Technical Information of China (English)

    苏显明; 马奕; 崔长琮

    2003-01-01

    Objectives To understand the effect of carvedilol on the coronary vascular endothelial function of the patients with coronary heart disease after percutaneous transluminal coronary angioplasty (PTCA). Methods 51cases, having one or more than two branches narrow ( ≥ 70% ) , were diagnosed by coronary angiography. These patients were divided randomly into carvedilol group (n = 28 ) and control group (n = 23) who did not take carvedilol.Endothelin (ET) and nitro dioxide (NO) levels of peripheral blood were measured before and after PTCA,before and after two weeks by taking carvedilol. Results Compared with the ET and NO levels before PTCA, ET were markedly increased and NO were decreased after PTCA (p < 0.05); compared with the ET and NO levels before taking carvedilol, ET were decreased and NO were increased after two week (p <0.05) , but the ET and NO levels of the control group did not change in the period of two weeks observation (p > 0.05). Conclusions Carvedilol may improve the coronary vascular endothelial function after PTCA.

  8. Percutaneous Aspiration Thrombectomy for the Treatment of Arterial Thromboembolic Occlusions Following Percutaneous Transluminal Angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Schleder, Stephan, E-mail: stephan.schleder@ukr.de [University Hospital Regensburg, Department of Radiology (Germany); Diekmann, Matthias [Radiology Center Rahlstedt (Germany); Manke, Christoph [General Hospital Fulda, Department of Radiology (Germany); Heiss, Peter [University Hospital Regensburg, Department of Radiology (Germany)

    2015-02-15

    PurposeThis study was designed to evaluate the technical success and the early clinical outcome of patients undergoing percutaneous aspiration thrombectomy (PAT) for the treatment of arterial thromboembolism following percutaneous infrainguinal transluminal angioplasty (PTA).MethodsIn this single-center study, during a period of 7 years retrospectively, 47 patients (22 male, 47 %) with a mean age of 73 (range 53–96) years were identified in whom PAT was performed for the treatment of thromboembolic complications of infrainguinal PTA. Primary technical success was defined as residual stenosis of <50 % in diameter after sole PAT, whereas secondary technical success was defined as residual stenosis of <50 % in diameter after PAT and additional PTA and/or stenting. Clinical outcome parameters (e.g., need for further intervention, minor/major amputation) were evaluated for the 30-day postinterventional period.ResultsPrimary technical success was achieved in 64 % of patients (30/47); secondary technical success was obtained in 96 % of patients (45/47). Clinical outcome data were available in 38 patients. In 87 % of patients (33/38), there was no need for further intervention within the 30-day postinterventional period. In three patients, minor amputations were conducted due to preexisting ulcerations (Rutherford Category 5 respectively).ConclusionsPAT enables endovascular treatment of iatrogenic thromboembolic complications after PTA with good technical and early clinical results and minimal morbidity.

  9. Below knee angioplasty in elderly patients: predictors of major adverse clinical outcomes.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2012-02-01

    AIM: To determine predictors of clinical outcome following percutaneous transluminal angioplasty (PTA) in elderly patients with below knee atherosclerotic lesions causing intermittent claudication (IC) or critical limb ischaemia (CLI). MATERIALS AND METHODS: Over 7.5 years, 76 patients (CLI 72%, n = 55) underwent below knee PTA. The composite end-point of interest was major adverse clinical outcome (MACO) of the treated limb at follow-up which was defined as clinical failure, need for subsequent endovascular or surgical revascularization or amputation. Actuarial freedom from MACO was assessed using Kaplan-Meier curves and multivariable Cox proportional hazards regression. RESULTS: IC was improved in 95% at mean 3.4 years (range 0.5-108 months). Successful limb salvage and ulcer healing were seen in 73% with CLI. Most failures were in the CLI group (27% CLI vs. 5% IC), with an amputation rate of 16% for CLI vs. 5% for IC and persistent ulceration in 24% of CLI. Significant independent predictors of MACO were ulceration (hazard ratio 4.02, 95% CI = 1.55-10.38) and family history of atherosclerosis (hazard ratio 2.53, 95% CI = 1.1-5.92). CONCLUSION: Primary below knee PTA is a feasible therapeutic option in this elderly population. Limb ulceration and family history of atherosclerosis may be independent predictors of adverse outcome.

  10. Femoral versus Radial Access in Primary Angioplasty. Analysis of the ACCEPT Registry

    International Nuclear Information System (INIS)

    The radial access provides a lower risk of bleeding and vascular complications related to the puncture site in comparison to the femoral access. Recent studies have suggested a reduction in mortality associated with the radial access in patients with acute myocardial infarction undergoing percutaneous coronary intervention. To compare the occurrence of adverse cardiovascular ischemic and hemorrhagic events in patients undergoing primary angioplasty according to the type of arterial access route. From August 2010 to December 2011, 588 patients undergoing primary percutaneous coronary intervention during acute ST-segment elevation myocardial infarction were assessed; they were recruited from 47 centers participating in the ACCEPT registry. Patients were grouped and compared according to the arterial access used for the procedure. The mean age was 61.8 years; 75% were males and 24% had diabetes mellitus. There was no difference between groups as regards the procedure success rate, as well as regards the occurrence of death, reinfarction, or stroke at six months of follow-up. Severe bleeding was reported in 1.1% of the sample analyzed, with no statistical difference related to the access used. The femoral and radial accesses are equally safe and effective for the performance of primary percutaneous coronary intervention. The low rate of cardiovascular events and of hemorrhagic complications reflects the quality of the participating centers and the operators expertise with the use of both techniques

  11. Below knee angioplasty in elderly patients: Predictors of major adverse clinical outcomes

    International Nuclear Information System (INIS)

    Aim: To determine predictors of clinical outcome following percutaneous transluminal angioplasty (PTA) in elderly patients with below knee atherosclerotic lesions causing intermittent claudication (IC) or critical limb ischaemia (CLI). Materials and methods: Over 7.5 years, 76 patients (CLI 72%, n = 55) underwent below knee PTA. The composite end-point of interest was major adverse clinical outcome (MACO) of the treated limb at follow-up which was defined as clinical failure, need for subsequent endovascular or surgical revascularization or amputation. Actuarial freedom from MACO was assessed using Kaplan-Meier curves and multivariable Cox proportional hazards regression. Results: IC was improved in 95% at mean 3.4 years (range 0.5-108 months). Successful limb salvage and ulcer healing were seen in 73% with CLI. Most failures were in the CLI group (27% CLI vs. 5% IC), with an amputation rate of 16% for CLI vs. 5% for IC and persistent ulceration in 24% of CLI. Significant independent predictors of MACO were ulceration (hazard ratio 4.02, 95% CI = 1.55-10.38) and family history of atherosclerosis (hazard ratio 2.53, 95% CI = 1.1-5.92). Conclusion: Primary below knee PTA is a feasible therapeutic option in this elderly population. Limb ulceration and family history of atherosclerosis may be independent predictors of adverse outcome.

  12. Primary percutaneous transluminal coronary angioplasty in the acute infarction of the right ventricle

    Directory of Open Access Journals (Sweden)

    Gligić Branko

    2003-01-01

    Full Text Available Background. Predilection site for the acute myocardial infarction of the right ventricle, (AMI-RV is the upper third of the right coronary artery and for this reason such an infarction is followed by numerous complications, primarily by conduction disorders and very often by sudden and rapid cardiogenic shock development. Methods. Primary percutaneous transluminal coronary angioplasty (PPTCA was performed on three patients in whom the acute infarction of the right ventricular was diagnosed and who had been hospitalized six hours after the beginning of chest pain. In all three patients intracoronary stent was implanted. On the admission patients had been in the threatening cardiogenic shock, with the prominent chest pain and with the elevation of ST-segment in V4R>2 mV. In the course of intervention patients were administered low-molecular intracoronary heparin with direct platelet glycoprotein IIb/IIIa inhibitors (abciximab, according to the established procedure applied in such cases. Results. The complete dilatation of the infarcted artery was established with the signs of reperfusion and the further clinical course was completely normal, there was no heart failure and patients had no subjective difficulties. Conclusion. Invasive approach in the treatment of AMI-RV is justifiable, and possibly the therapy of choice of these patients, providing well trained and equipped team is available.

  13. Treatment of an Immature Autogenous Arteriovenous Fistula with Percutaneous Transluminal Angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Rae [Kangwon National University, Chuncheon (Korea, Republic of)

    2008-11-15

    The purpose of this study was to evaluate the efficacy of percutaneous transluminal angioplasty (PTA) in facilitating maturation of autogenous arteriovenous fistulae. There were 12 immature autogenous arteriovenous fistulae. We performed 15 PTAs transvenously. Post-intervention anatomic and clinical successes were estimated, and the 6-month and 1-year primary and secondary patency rates were calculated using Kaplan-Meier analysis. All immature fistulae had underlying stenosis (n=20): arteriovenous anastomosis (n=1) and venous outflow (n=19): 1) within 5 cm from the anastomosis (n=10); 2) more than 5 cm but less than 10 cm from the anastomosis (n=5); 3) more than 10 cm from the anastomosis, including central veins (n=4). Six fistulae had two or more stenoses. Repeat intervention was necessary in two patients. The anatomical success rate was 94.3%, and the clinical success rate was 86.7%. The 6-month and 1-year primary patency rates were 72.7% and 54.5%, and the secondary patency rates were 100% and 81.8%, respectively. All immature hemodialysis fistulae have underlying stenosis, most of which are located near the arteriovenous anastomosis. Early interventional procedures are helpful in the salvage and maintenance of immature arteriovenous fistulae, with a high degree of success

  14. Optimization and audit of radiation dose during percutaneous transluminal coronary angioplasty

    Directory of Open Access Journals (Sweden)

    Livingstone Roshan

    2007-01-01

    Full Text Available The percutaneous transluminal coronary angioplasty (PTCA is one of the interventional procedures which impart high radiation doses to patients compared to the other cardiologic procedures. This study intends to audit and optimize radiation dose imparted to patients undergoing PTCA. Forty-four patients who underwent PTCA involving single or multiple stent placement guided under cardiovascular X-ray machine were included in the study. Radiation doses were measured using dose area product (DAP meter for patients undergoing single and multiple stent placements during PTCA. A dose reduction of 27-47% was achieved using copper filters and optimal exposure parameters. The mean DAP values before optimization were 66.16 and 122.68 Gy cm 2 for single and multiple stent placement respectively. These values were 48.67 and 65.44 Gy cm 2 respectively after optimization. In the present scenario, due to the increase in the number of PTCAs performed and the associated risk from radiation, periodical audit of radiation doses for interventional procedures are recommended.

  15. Long-Duration Altitude-Controlled Balloons for Venus: A Feasibility Study Informed by Balloon Flights in Remote Environments on Earth

    Science.gov (United States)

    Voss, P. B.; Nott, J.; Cutts, J. A.; Hall, J. L.; Beauchamp, P. M.; Limaye, S. S.; Baines, K. H.; Hole, L. R.

    2013-12-01

    In situ exploration of the upper atmosphere of Venus, approximately 65-77 km altitude, could answer many important questions (Limaye 2013, Crisp 2013). This region contains a time-variable UV absorber of unknown composition that controls many aspects of the heat balance on Venus. Understanding the composition and dynamics of this unknown absorber is an important science goal; in situ optical and chemical measurements are needed. However, conventional approaches do not provide access to this altitude range, repeated traverses, and a mission lifetime of several months needed to effectively carry out the science. This paper examines concepts for altitude-controlled balloons not previously flown on planetary missions that could potentially provide the desired measurements. The concepts take advantage of the fact that at 60 km altitude, for example, the atmospheric density on Venus is about 40% of the sea-level density on earth and the temperature is a moderate 230 K. The solar flux is approximately double that on earth, creating some thermal challenges, but making photovoltaic power highly effective. Using a steady-state thermodynamic model and flight data from Earth, we evaluate the suitability of two types of altitude-controlled balloons for a potential mission on Venus. Such balloons could repeatedly measure profiles, avoid diurnal temperature extremes, and navigate using wind shear. The first balloon design uses air ballast (AB) whereby ambient air can be compressed into or released from a constant-volume balloon, causing it to descend or ascend accordingly. The second design uses lift-gas compression (LGC) to change the volume of a zero-pressure balloon, thereby changing its effective density and altitude. For an altitude range of 60-75 km on Venus, we find that the superpressure volume for a LGC balloon is about 5% of that needed for an AB balloon while the maximum pressurization is the same for both systems. The compressor work per km descent of the LGC balloon

  16. The readout electronic of EUSO-Balloon experiment

    Science.gov (United States)

    Ahmad, S.; Barrillon, P.; Blaksley, C.; Blin-Bondil, S.; Ebersoldt, A.; Dagoret-Campagne, S.; de la Taille, C.; Dulucq, F.; Gorodetzky, P.; Miyamoto, H.; Moretto, C.; Prévôt, G.; Reina, J. A. R.

    2014-03-01

    The EUSO-Balloon experiment is a pathfinder for the satellite mission JEM-EUSO whose goal will be to observe Extensive Air Showers produced in the atmosphere by the passage can detect fluorescent UV photons released by the EAS thanks to Multi-anode photomultipliers (MAPMT) arranged in 6 × 6 matrices inside Photo Detector Modules (PDM). A set of lenses is used to focus the photons on the PDM which can be compared to a UV camera taking pictures every 2.5 μs period (GTU: Gate Time Unit). The experiment consists in launching a balloon, at an altitude of 40 km, equipped with complete PDM and Data Processing systems. This project, supported by CNES and constructed by the JEM-EUSO collaboration, is meant to prove that the technology of such an instrument is possible and that the performance is satisfying, raising the Technical Readiness Level (TRL) of JEM-EUSO. Moreover, complex trigger algorithms will be assessed and the main back ground (night glow plus star light) will be studied. A complex readout electronic chain has been designed for the EUSO-Balloon project. It contains two elements: the 9 EC units and the 6 EC-ASIC boards. The EC unit includes four 64-channel Multi-Anode Photomultipliers and a set of pcbs used to supply the 14 different high voltages needed by the MAPMTs and to read out the analog anode signals. These signals are transmitted to the EC-ASIC boards which contain 6 SPACIROC ASICs each. During the year 2012, prototypes of each board were produced and tested successfully, leading to the production of the flight model PCBs in 2013.

  17. Biogenic nonmethane hydrocarbon emissions estimated from tethered balloon observations

    Science.gov (United States)

    Davis, K. J.; Lenschow, D. H.; Zimmerman, P. R.

    1994-01-01

    A new technique for estimating surface fluxes of trace gases, the mixed-layer gradient technique, is used to calculate isoprene and terpene emissions from forests. The technique is applied to tethered balloon measurements made over the Amazon forest and a pine-oak forest in Alabama at altitudes up to 300 m. The observations were made during the dry season Amazon Boundary Layer Experiment (ABLE 2A) and the Rural Oxidants in the Southern Environment 1990 experiment (ROSE I). Results from large eddy simulations of scalar transport in the clear convective boundary layer are used to infer fluxes from the balloon profiles. Profiles from the Amazon give a mean daytime emission of 3630 +/- 1400 micrograms isoprene sq m/h, where the uncertainty represents the standard deviation of the mean of eight flux estimates. Twenty profiles from Alabama give emissions of 4470 +/- 3300 micrograms isoprene sq m/h, 1740 +/- 1060 micrograms alpha-pinene sq m/h, and 790 +/- 560 micrograms beta-pinene sq m/h, respectively. These results are in agreement with emissions derived from chemical budgets. The emissions may be overestimated because of uncertainty about how to incorporate the effects of the canopy on the mixed-layer gradients. The large variability in these emission estimates is probably due to the relatively short sampling times of the balloon profiles, though spatially heterogeneous emissions may also play a role. Fluxes derived using this technique are representative of an upwind footprint of several kilometers and are independent of hydrocarbon oxidation rate and mean advection.

  18. Fine tracking system for balloon-borne telescopes

    OpenAIRE

    Ricci, M.; Pedichini, F.; Lorenzetti, D.

    2011-01-01

    We present the results of a study along with a first prototype of a high precision system (? 1 arcsec) for pointing and tracking light (near-infrared) telescopes on board stratospheric balloons. Such a system is essentially composed by a star sensor and by a star tracker, able to recognize the field and to adequately track the telescope, respectively. We present the software aimed at processing the star sensor image and the predictive algorithm that allows the fine tracking of the source at a...

  19. Balloon-borne observations of mid-latitude hydrofluoric acid

    Science.gov (United States)

    Sen, B.; Toon, G. C.; Blavier, J.-F.; Szeto, J. T.; Fleming, E. L.; Jackman, C. H.

    1995-01-01

    Measurements of stratospheric hydrofluoric acid (HF) have been made by the JPL MkIV interferometer during high-altitude balloon flights. Infrared solar absorption spectra were acquired near 35 deg N at altitudes between local tropopause and 38 km. Volume mixing ratio profiles of HF derived from 4 flights (1990-93), in conjunction with simultaneously observed N2O profiles, indicate an average rate of HF increase of (5.5 +/- 0.3)% per year, in agreement with time-dependent, two-dimensional model simulations (6% per year) and ATMOS measurements.

  20. Pointing System for the Balloon-Borne Astronomical Payloads

    CERN Document Server

    Nirmal, K; Mathew, Joice; Sarpotdar, Mayuresh; Suresh, Ambily; Prakash, Ajin; Safonova, Margarita; Murthy, Jayant

    2016-01-01

    We describe the development and implementation of a light-weight, fully autonomous 2-axis pointing and stabilization system designed for balloon-borne astronomical payloads. The system is developed using off-the-shelf components such as Arduino Uno controller, HMC 5883L magnetometer, MPU-9150 Inertial Measurement Unit (IMU) and iWave GPS receiver unit. It is a compact and rugged system which can also be used to take images/video in a moving vehicle, or in areal photography. The system performance is evaluated from the ground, as well as in conditions simulated to imitate the actual flight by using a tethered launch.