Sample records for angioplasty balloon

  1. Balloon catheter coronary angioplasty

    International Nuclear Information System (INIS)

    The author has produced a reference and teaching book on balloon angioplasty. Because it borders in surgery and is performed on an awake patient without circulatory assistance, it is a complex and demanding procedure that requires thorough knowledge before it is attempted. The text is divided into seven sections. The first section describes coronary anatomy and pathophysiology, defines the objectives and mechanisms of the procedure and lists four possible physiologic results. The next section describes equipment in the catheterization laboratory, catheters, guidewires and required personnel. The following section is on the procedure itself and includes a discussion of examination, testing, technique and follow-up. The fourth section details possible complications that can occur during the procedure, such as coronary spasms, occlusion, thrombosis, perforations and ruptures, and also discusses cardiac surgery after failed angioplasty. The fifth section details complex or unusual cases that can occur. The sixth and seventh sections discuss radiation, alternative procedures and the future of angioplasty

  2. Cutting Balloon angioplasty for cardiac transplant vasculopathy.

    OpenAIRE

    Takano, Y.; Currier, JW; Yeatman, LA; Kobashigawa, JA; Rogers, AD; Cianfichi, LJ; Fishbein, MC; Tobis, JM

    2002-01-01

    We performed Cutting Balloon angioplasty on 20 lesions in 11 heart transplant recipients 7.5 +/- 3.8 years after transplantation. The mean percentage of diameter stenosis decreased from 88.3% +/- 13.8% to 19.6% +/- 13.7% after Cutting Balloon angioplasty without complication. Seven patients underwent follow-up angiography at 4.9 +/- 1.7 months in a total of 12 lesions, and all lesions showed restenosis with a mean diameter stenosis of 84.4% +/- 19.2%. Cutting Balloon angioplasty can be used t...

  3. Intravascular ultrasound imaging following balloon angioplasty.

    Science.gov (United States)

    Tobis, J M; Mahon, D J; Moriuchi, M; Honye, J; McRae, M

    1991-01-01

    Despite its long history and reliability, contrast angiography has several inherent limitations. Because it is a two-dimensional projection image of the lumen contour, the wall thickness cannot be measured and the plaque itself is not visualized. This results in an underestimation of the amount of atherosclerotic disease by angiography. An assessment of atherosclerosis could be improved by an imaging modality: (1) that has an inherent larger magnification than angiography and (2) that directly visualizes the plaque. Intravascular ultrasound fulfils these criteria. This presentation will provide evidence that intravascular ultrasound may prove complimentary or even superior to angiography as an imaging modality. Intravascular ultrasound demonstrates excellent representations of lumen and plaque morphology of in vitro specimens compared with histology. There is very close intraobserver and interobserver variability of measurements made from intravascular ultrasound images. Phantom studies of stenoses in a tube model demonstrate that angiography can misrepresent the severity of stenosis when the lumen contour is irregular and not a typical ellipse, whereas intravascular ultrasound reproduces the cross-sectional morphology more accurately since it images the artery from within. In vitro studies of the atherosclerotic plaque tissue characteristics compare closely with the echo representation of fibrosis, calcification, and lipid material. In addition, in vitro studies of balloon angioplasty demonstrate that intravascular ultrasound accurately represents the changes in the structure of artery segments following balloon dilatation. PMID:1833473

  4. Three dimensional intravascular ultrasonic assessment of the local mechanism of restenosis after balloon angioplasty

    NARCIS (Netherlands)

    M.A. Costa (Marco); P.J. de Feyter (Pim); K. Kozuma (Ken); A.L. Gaster; M. Sabaté (Manel); I.P. Kay (Ian Patrick); J.M.R. Ligthart (Jürgen); P. Thayssen; M.J.B.M. van den Brand (Marcel); P.W.J.C. Serruys (Patrick); D.P. Foley (David); W.J. van der Giessen (Wim)

    2001-01-01

    textabstractOBJECTIVE: To assess the mechanism of restenosis after balloon angioplasty. DESIGN: Prospective study. PATIENTS: 13 patients treated with balloon angioplasty. INTERVENTIONS: 111 coronary subsegments (2 mm each) were analysed after balloon angioplasty and at a six month follow up using th

  5. Modeling plaque fissuring and dissection during balloon angioplasty intervention.

    Science.gov (United States)

    Gasser, T Christian; Holzapfel, Gerhard A

    2007-05-01

    Balloon angioplasty intervention is traumatic to arterial tissue. Fracture mechanisms such as plaque fissuring and/or dissection occur and constitute major contributions to the lumen enlargement. However, these types of mechanically-based traumatization of arterial tissue are also contributing factors to both acute procedural complications and chronic restenosis of the treatment site. We propose physical and finite element models, which are generally useable to trace fissuring and/or dissection in atherosclerotic plaques during balloon angioplasty interventions. The arterial wall is described as an anisotropic, heterogeneous, highly deformable, nearly incompressible body, whereas tissue failure is captured by a strong discontinuity kinematics and a novel cohesive zone model. The numerical implementation is based on the partition of unity finite element method and the interface element method. The later is used to link together meshes of the different tissue components. The balloon angioplasty-based failure mechanisms are numerically studied in 3D by means of an atherosclerotic-prone human external iliac artery, with a type V lesion. Image-based 3D geometry is generated and tissue-specific material properties are considered. Numerical results show that in a primary phase the plaque fissures at both shoulders of the fibrous cap and stops at the lamina elastica interna. In a secondary phase, local dissections between the intima and the media develop at the fibrous cap location with the smallest thickness. The predicted results indicate that plaque fissuring and dissection cause localized mechanical trauma, but prevent the main portion of the stenosis from high stress, and hence from continuous tissue damage. PMID:17385047

  6. Parallel wire balloon angioplasty for undilatable venous stenosis in hemodialysis fistula

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Tae Beom; You, Jin Jong; Cho, Jae Min [Gyeongsang National University Hospital, Jinju (Korea, Republic of)] (and others)

    2007-05-15

    The purpose of this study was to assess the value of the parallel wire balloon angioplasty technique for treating dysfunctional hemdialysis fistula with rigid stenosis, and this type of lesion was resistant to conventional angioplasty. Between March 2002 and August 2003, we included 6 patients (mean age: 59, males: 2, females: 4) who were treated via parallel the wire balloon angioplasty technique and their hemodialysis fistula has stenoses that were resistant to conventional angioplasty. We performed conventional angioplasty in all patients, but we failed to achieve sufficient dilatation. In the cases of highly resistant stenosis, an additional 0.016 inch wire was inserted into the 7 F vascular sheath. During angioplasty, a 0.016 inch guide wire was inserted between the balloon and the stenosis and then it was pushed to and fro until the balloon indentation disappeared. After the procedure, we performed angiography to identify the residual stenosis and the procedure-related complications. The undilatable stenoses in 5 patients were successfully resolved without complications via the parallel wire angioplasty technique. In one patient, indentation of balloon was not resolved, but the residual stenosis was both minimal and hemodynamically insignificant. The parallel wire angioplasty technique seems to be a feasible and cost-effective method for treating a dysfunctional hemodialysis fistula with undilatable and rigid stenosis.

  7. Absence of Bacteria on Coronary Angioplasty Balloons from Unselected Patients

    DEFF Research Database (Denmark)

    Hansen, Gorm Mørk; Nilsson, Martin; Nielsen, Claus Henrik;

    2015-01-01

    Periodontitis is a chronic, bacterially-induced inflammatory disease of the tooth-supporting tissues, which may result in transient bacteremia and a systemic inflammatory response. Periodontitis is associated with coronary artery disease independently of established cardiovascular risk factors, and...... translocation of bacteria from the oral cavity to the coronary arteries may play a role in the development of coronary artery disease. Very few studies have used angioplasty balloons for in vivo sampling from diseased coronary arteries, and with varying results. Therefore, the aim of this study was to assess if...... patients with stable angina, unstable angina/non-ST elevation myocardial infarction, and ST-elevation myocardial infarction (n = 15 in each group) were collected and analyzed using a PCR assay with high sensitivity and specificity for 16S rRNA genes of the oral microbiome. Despite elimination of extraction...

  8. A cutting balloon for coronary angioplasty: new trend in the prevention of restenoses

    International Nuclear Information System (INIS)

    Results on application of angioplasty with a cutting balloon in 8 men with ischemia heart disease are presented all patients had injury of one coronary vessel. The first experience makes it possible to consider that application of a cutting balloon is not dangerous, the arteria wall traumatization is small and restonoses frequency should be consequently smaller. 7 refs.; 3 figs

  9. Comparison of a nitinol stent versus balloon angioplasty for treatment of a dysfunctional arteriovenous graft

    International Nuclear Information System (INIS)

    This study aimed to 1) evaluate the outcome of placing a nitinol stent for treating dysfunctional arteriovenous grafts (AVG), and 2) compare the results with those of successful balloon angioplasty. Between February 2008 and October 2011, we retrospectively reviewed the interventional data and medical records of 29 patients (21 men, 8 women; mean age, 67.4 years) who underwent interventional procedures for dysfunctional AVG. Stents were placed only in cases with inadequate angioplasty results. Stent patency was evaluated and compared to cases of successful balloon angioplasty using the Kaplan Meier analysis. Eleven stents and 18 angioplasties were performed successfully at the venous anastomotic site of AVG. The primary patency at 3, 6, 12, and 18 months did not differ significantly for stent placement and angioplasty (52%, 29%, 15%, 15% vs. 71%, 50%, 34%, 34%; mean survival, 164 vs. 253 days, p = 0.283). Secondary patency of the stent also did not differ significantly from angioplasty (80%, 80%, 49%, 49% vs. 76%, 57%, 57%, 36%; mean survival, 405 vs. 385 days, p = 0.553). Nitinol stent placement was effective for treating dysfunctional AVG, but did not improve the primary and secondary patency compared to successful angioplasty

  10. Postpartum cerebral angiopathy: atypical features and treatment with intracranial balloon angioplasty

    International Nuclear Information System (INIS)

    Postpartum cerebral angiopathy (PCA) is an uncommon cause of ischemic and hemorrhagic stroke in young women. It is usually clinically benign and not relapsing. We describe a patient with non-hemorrhagic PCA who had an atypical progressive neurological deficit from bilateral hemisphere watershed ischemia despite treatment with aggressive medical therapy and intracranial balloon angioplasty. (orig.)

  11. Postpartum cerebral angiopathy: atypical features and treatment with intracranial balloon angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Song, J.K. [Center for Endovascular Surgery, Hyman-Newman Inst. for Neurology and Neurosurgery, New York, NY (United States); Cacayorin, E.D. [Interventional Neuroradiology, Dept. of Radiology, Univ. of Texas Medical School, Houston, TX (United States); Fisher, S.; Seifert, T.D.; Alexandrov, A.V.; Malkoff, M.D.; Grotta, J.C.; Campbell, M.S. [Div. of Stroke Neurology, Dept. of Neurology, Univ. of Texas Medical School, Houston, TX (United States)

    2004-12-01

    Postpartum cerebral angiopathy (PCA) is an uncommon cause of ischemic and hemorrhagic stroke in young women. It is usually clinically benign and not relapsing. We describe a patient with non-hemorrhagic PCA who had an atypical progressive neurological deficit from bilateral hemisphere watershed ischemia despite treatment with aggressive medical therapy and intracranial balloon angioplasty. (orig.)

  12. Wiktor stent implantation in patients with restenosis following balloon angioplasty of a native coronary artery

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); M.E. Bertrand (Michel); V. Wiegand; G. Kober; J.F. Marquis; B. Valeix; R. Uebis; J. Piessen; P.P.T. de Jaegere (Peter)

    1992-01-01

    textabstractIntracoronary stenting has been introduced as an adjunct to balloon angioplasty aimed at overcoming its limitations, namely acute vessel closure and late restenosis. This study reports the first experience with the Wiktor stent implanted in the first 50 consecutive patients. All patients

  13. Cost-effectiveness analysis of orbital atherectomy plus balloon angioplasty vs balloon angioplasty alone in subjects with calcified femoropopliteal lesions

    Directory of Open Access Journals (Sweden)

    Weinstock B

    2014-03-01

    Full Text Available Barry Weinstock,1 Raymond Dattilo,2 Tiffini Diage3 1Orlando Health Heart Institute, Mid-Florida Cardiology Specialists, Orlando, FL, USA; 2Department of Cardiology, St Francis Health Center, Topeka, KS, USA; 3North American Science Association (NAMSA, Sunnyvale, CA, USA Introduction: As cost considerations become increasingly critical when selecting optimal endovascular treatment strategies, a cost-benefit analysis was conducted comparing the Diamondback 360°® Orbital Atherectomy System (OAS (Cardiovascular Systems, Inc., St Paul, MN, USA and balloon angioplasty (BA vs BA alone for treatment of calcified femoropopliteal lesions. Patients and methods: The clinical outcomes from COMPLIANCE 360°, a prospective, multicenter, randomized study comparing OAS+BA vs BA alone for treatment of calcified femoropopliteal lesions, were correlated with cost data and previously published quality of life data. Site of service, hospital charges, and associated medical resource utilization were obtained from Uniform Billing statements for index treatments and associated revascularizations out to 1 year. Hospital costs were estimated using hospital-specific, procedure-specific cost-to-charge ratios. Length of stay and procedural data were collected from participating study sites. Results: Twenty-five subjects with 38 lesions and 25 subjects with 27 lesions were randomized to the OAS+BA and BA-alone groups, respectively. Mean hospital charges (US$51,755 vs US$39,922 and estimated hospital costs (US$15,100 vs US$11,016 were higher for OAS+BA compared with BA alone (not statistically significant. Stent utilization was statistically significantly higher with BA-alone treatment for all subjects (1.1 vs 0.1, P=0.001 and in the subset of subjects with one lesion (1.0 vs 0.1, P<0.00001. There was a significant difference in cost for single-lesion versus multiple-lesion treatment. Using costs and quality-adjusted life years (QALYs for the single-lesion cohort, the 1-year

  14. Evaluation of interventional angioplasty by using thrombolysis and balloon dilatation in treating pulmonary embolism

    International Nuclear Information System (INIS)

    Objective: To evaluate the interventional angioplasty by using thrombolysis and balloon dilatation in the treatment of pulmonary embolism. Methods: Eight patients with pulmonary embolism were treated with interventional management including fragmentation of the thrombus, thrombolysis with urokinase flush infusion, balloon dilatation and continuing low-dose infusion for 24 hours. Anticoagulation with heparin was given simultaneously. Results: The pulmonary artery was completely recanalized in three patients, and partially recanalized in five patients. The blood oxygen saturation reached 100% in 3 cases and was over 93% in 5 cases. Conclusion: Interventional angioplasty by means of thrombolysis or balloon dilatation is an effective therapy for pulmonary embolism in reopening the embolized pulmonary artery, bringing the pulmonary hemodynamics to normal condition and correcting the hypoxemia. (authors)

  15. Rupture of the Renal Artery After Cutting Balloon Angioplasty in a Young Woman With Fibromuscular Dysplasia

    International Nuclear Information System (INIS)

    A 24-year-old woman with uncontrollable high blood pressure for 3 months had significant stenosis of the left renal artery caused by fibromuscular dysplasia (FMD). The lesion was resistant to percutaneous transluminal angioplasty at 18 atm with a semicompliant balloon. Angioplasy with a 6 x 10 mm cutting balloon (CB) caused rupture of the artery. Low-pressure balloon inflation decreased but did not stop the leak. An attempt to place a stent-graft (Jostent; Jomed, Rangendingen, Germany) failed, and a bare, 6-mm balloon-expandable stent (Express SD; Boston Scientific, MN) was deployed to seal the leak, which had decreased considerably after long-duration balloon inflation. The bleeding continued, and the patient underwent emergent surgical revascularization of the renal artery with successful placement of a 6-mm polytetrafluoroethylene bypass graft. CBs should be used very carefully in the treatment of renal artery stenosis, particularly in patients with FMD

  16. Cutting-Balloon Angioplasty Versus Balloon Angioplasty as Treatment for Short Atherosclerotic Lesions in the Superficial Femoral Artery: Randomized Controlled Trial

    International Nuclear Information System (INIS)

    Purpose: To evaluate the treatments of a short-segment atherosclerotic stenosis in the superficial femoral arteries with the cutting balloon angioplasty (CBA) versus conventional balloon angioplasty [percutaneous transluminal angioplasty (PTA)] in a randomized controlled trial. Material and Methods: The study group comprised 60 patients (33 men, 27 women; average age 64 years) with a short (≤5 cm) focal SFA de novo atherosclerotic stenosis associated with a history of intermittent claudication or rest pain. The primary end point of this study was the rate of binary restenosis in the treated segment 12 months after the intervention. All patients were evenly randomized to either the PTA or CBA treatment arms. Follow-up angiograms and ankle–brachial index (ABI) measurements were performed after 12 months. The evaluation of the restenosis rates and factors influencing its occurrence were calculated by logistic regression analysis. Results: In the intention-to-treat analysis, restenosis rates after 2-month follow-up were 9 of 30 (30 %) in the PTA group and 4 of 30 (13 %) in the CBA group (p = 0.117). In the actual treatment analysis, after exclusion of patients who required nitinol stent placement for a suboptimal result after angioplasty alone (5 patients in the PTA group and none in the CBA group), restenosis rates were 9 of 25 (36 %) and 4 of 30 (13 %), respectively (p = 0.049). In the intention-to-treat analysis there were also significant differences in ABI values between the PTA and CBA groups at 0.77 ± 0.11 versus 0.82 ± 0.12, respectively (p = 0.039), at 12 months. Conclusion: Based on the presented results of the trial, CBA seems to be a safer and more effective than PTA for treatment of short atherosclerotic lesions in the superior femoral artery

  17. Cutting-Balloon Angioplasty Versus Balloon Angioplasty as Treatment for Short Atherosclerotic Lesions in the Superficial Femoral Artery: Randomized Controlled Trial

    Energy Technology Data Exchange (ETDEWEB)

    Poncyljusz, Wojciech, E-mail: wponcyl@poczta.onet.pl; Falkowski, Aleksander, E-mail: bakhis@hot.pl [Pomeranian Medical University, Department of Interventional Radiology (Poland); Safranow, Krzysztof, E-mail: chrissaf@mp.pl; Rac, Monika, E-mail: carmon@pum.edu.pl [Pomeranian Medical University, Department of Biochemistry and Medical Chemistry (Poland); Zawierucha, Dariusz, E-mail: dariusz13@yahoo.com [Interventional Radiology, Sacred Heart Medical Center, River Bend (United States)

    2013-12-15

    Purpose: To evaluate the treatments of a short-segment atherosclerotic stenosis in the superficial femoral arteries with the cutting balloon angioplasty (CBA) versus conventional balloon angioplasty [percutaneous transluminal angioplasty (PTA)] in a randomized controlled trial. Material and Methods: The study group comprised 60 patients (33 men, 27 women; average age 64 years) with a short ({<=}5 cm) focal SFA de novo atherosclerotic stenosis associated with a history of intermittent claudication or rest pain. The primary end point of this study was the rate of binary restenosis in the treated segment 12 months after the intervention. All patients were evenly randomized to either the PTA or CBA treatment arms. Follow-up angiograms and ankle-brachial index (ABI) measurements were performed after 12 months. The evaluation of the restenosis rates and factors influencing its occurrence were calculated by logistic regression analysis. Results: In the intention-to-treat analysis, restenosis rates after 2-month follow-up were 9 of 30 (30 %) in the PTA group and 4 of 30 (13 %) in the CBA group (p = 0.117). In the actual treatment analysis, after exclusion of patients who required nitinol stent placement for a suboptimal result after angioplasty alone (5 patients in the PTA group and none in the CBA group), restenosis rates were 9 of 25 (36 %) and 4 of 30 (13 %), respectively (p = 0.049). In the intention-to-treat analysis there were also significant differences in ABI values between the PTA and CBA groups at 0.77 {+-} 0.11 versus 0.82 {+-} 0.12, respectively (p = 0.039), at 12 months. Conclusion: Based on the presented results of the trial, CBA seems to be a safer and more effective than PTA for treatment of short atherosclerotic lesions in the superior femoral artery.

  18. Acute occlusion of the coronary artery after transluminal balloon coronary angioplasty

    International Nuclear Information System (INIS)

    The research was aimed at elucidation of the relationship of the clinical and angiographic factors, on the one hand, and development of acute occlusion following transluminal balloon coronary angioplasty TBCA, on the other. TBCA was carried out in 162 patients. Eight (4.9 %) patients developed acute occlusion of the coronary artery, which was complicated by acute myocardial infarction in 50 % cases. 35 refs.; 4 tabs

  19. Unusual Response of Subclavian In-Stent Restenosis to Balloon Angioplasty in a Patient with HIV

    Directory of Open Access Journals (Sweden)

    Mohammad Atif Rana

    2015-01-01

    Full Text Available Human Immunodeficiency Virus (HIV infection and use of protease inhibitors have been associated with accelerated atherosclerosis. Increased rates of coronary in-stent restenosis are reported in these patients. There is limited data available on peripheral vascular disease interventions on these patients. Herein we report an aggressive subclavian in-stent restenosis with an unexpected response to balloon angioplasty treatment with a large, mobile tissue flap formation and its treatment with another stent.

  20. Ureteric angioplasty balloon placement to increase localised dosage of BCG for renal pelvis TCC.

    LENUS (Irish Health Repository)

    Forde, J C

    2012-03-01

    Endoscopic percutaneous resection of a renal pelvis transitional cell carcinoma (TCC) is a viable treatment option in those who would be rendered dialysis dependent following a nephroureterectomy. We report endoscopic percutaneous resection of an upper tract TCC recurrence in a single functioning kidney followed by antegrade renal pelvis BCG instillation with novel placement of inflated angioplasty balloon in the ureter to help localise its effect.

  1. Characterization of Pebax angioplasty balloon surfaces with AFM, SEM, TEM, and SAXS.

    Science.gov (United States)

    Warner, Jacob A; Forsyth, Bruce; Zhou, Fang; Myers, Jason; Frethem, Chris; Haugstad, Greg

    2016-04-01

    In the medical device industry, angioplasty balloons have been widely used in the less invasive treatment of heart disease by expanding and relieving clogged structures in various arterial segments. However, new applications using thin coatings on the balloon surface have been explored to enhance therapeutic value in the delivery of pharmaceuticals (drug-elution) or control thermal energy output (RF ablation). In this study, angioplasty balloon materials comprised of poly(ether-block-amide) (Pebax) were investigated via atomic force microscopy (AFM), transmission electron microscopy (TEM), scanning electron microscopy (SEM), and small-angle X-ray scattering (SAXS) to characterize physical properties at the balloon surface that may affect coating adhesion. The soft segment of this Pebax 1074 material is polyethylene oxide (PEO) and the hard segment is nylon-12. The morphology of the hard segments of this block co-polymer are found via AFM stiffness measurements to be (40 ± 20) nm by (300 ± 150) nm and are oriented parallel to the surface of the balloon. SAXS measurements found the lamellar spacing to be (18.5 ± 0.5) nm, and demonstrate a preferential orientation in agreement with TEM and AFM measurements. Fixation of this balloon in resin, followed by cryo-sectioning is shown to provide a novel manner in which to investigate surface characteristics on the balloon such as material or coating thickness as well as uniformity in comparison to the bulk structure. These outputs were deemed critical to improve overall balloon processing such as molding and surface treatment options for robust designs toward better procedural outcomes targeting new therapeutic areas. PMID:25891789

  2. Cutting Balloon-Assisted Angioplasty of an Anastomotic Carotid-Brachial Bypass Graft Stenosis: A Case Report

    International Nuclear Information System (INIS)

    Neointimal hyperplasia leads to anastomotic stenosis in bypass grafts. These stenoses are often resistant to conventional balloon dilatation. We present a case of a carotid-brachial bypass graft stenosis, which was treated by a 5-mm cutting balloon angioplasty with a good angiographic and clinical result

  3. Infrapopliteal Percutaneous Transluminal Balloon Angioplasty: Clinical Results and Influence Factors

    Energy Technology Data Exchange (ETDEWEB)

    Song, Jang Hyeon; Lee, Seung Jin; Jung, Hye Doo; Lim, Jae Hoon; Chang, Nam Kyu; Yim, Nam Yeol; Kim, Jae Kyu [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Lee, Keun Bae [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2011-09-15

    To assess the efficacy of percutaneous transluminal angioplasty (PTA) in patients with infrapopliteal arterial disease, and to determine the influencing factor for prognosis. A total of 55 patients (60 limbs) with infrapopliteal arterial stenosis or occlusion underwent PTA. Atherosclerotic risk factors, clinical symptoms, TransAtlantic Inter-Society Consensus (TASC) classification, and vascular wall calcification were evaluated before PTA. The number of patent infrapopliteal arteries was estimated, and the outcome was evaluated by symptom relief and limb salvage. Technical success was achieved in 53/60 limbs (88.3%) and 81/93 arteries (87.1%), TASC classification (p = 0.038) and vascular calcification (p = 0.002) influenced on technical failure. During follow-up, 26 of 55 limbs (47%) achieved symptom relief and 42/55 limbs (76%) underwent limb salvage. Non-diabetic patients (9/12, 75%) were superior to diabetic patients (17/43, 40%) in terms of symptom relief (p = 0.024). TASC classification and vascular wall calcification influenced on symptom relief and limb salvage. The number of patent infrapopliteal arteries after PTA influenced symptom relief (p < 0.001) and limb amputation (p = 0.003). PTA in patients with chronic critical limb ischemia is worthwhile as a primary treatment. The influence factors should be considered before PTA, and PTA should be performed in as many involved arteries as possible.

  4. Balloon pulmonary angioplasty: a treatment option for inoperable patients with chronic thromboembolic pulmonary hypertension

    Directory of Open Access Journals (Sweden)

    Aiko eOgawa

    2015-02-01

    Full Text Available In chronic thromboembolic pulmonary hypertension, stenoses or obstructions of the pulmonary arteries due to organized thrombi can cause an elevation in pulmonary artery resistance, which in turn can result in pulmonary hypertension. Chronic thromboembolic pulmonary hypertension can be cured surgically by pulmonary endarterectomy; however, patients deemed unsuitable for pulmonary endarterectomy due to lesion, advanced age, or comorbidities have a poor prognosis and limited treatment options. Recently, advances have been made in balloon pulmonary angioplasty for these patients, and this review highlights this recent progress.

  5. The effects of 103Pd radioactive stent on restenosis after balloon angioplasty in rabbits

    International Nuclear Information System (INIS)

    Objective: To investigate the preventive effects of 103Pd radioactive stent on restenosis after balloon angioplasty in rabbits. Methods: 50 New Zealand white rabbits were balloon injured on abdominal aorta and followed by intravascular stent with ordinary or 103Pd radioactive stent, respectively. At the end of 3 days, 1, 2, 4 and 8 weeks after injury, the animals were killed in time-subgroups. Abdominal aortas were examined immuno-histochemically and pathologically. Before sacrifice, the two 8-week subgroups of rabbits received angiography. Result: Compared with the rabbits received ordinary stent, the rate of neo-intimal proliferation and vascular stenosis in rabbits received 103Pd radioactive stent were suppressed. Conclusion: It is showed that 103Pd radioactive stent could prevent arterial restenosis and the 103Pd being used as a radioactive agent in the procedure is safe and effective

  6. Critical appraisal of paclitaxel balloon angioplasty for femoral–popliteal arterial disease

    Science.gov (United States)

    Herten, Monika; Torsello, Giovanni B; Schönefeld, Eva; Stahlhoff, Stefan

    2016-01-01

    Peripheral arterial disease, particularly critical limb ischemia, is an area with urgent need for optimized therapies because, to date, vascular interventions often have limited life spans. In spite of initial encouraging technical success after femoropopliteal percutaneous transluminal angioplasty or stenting, postprocedural restenosis remains the major problem. The challenging idea behind the drug-coated balloon (DCB) concept is the biological modification of the injury response after balloon dilatation. Antiproliferative drugs administered via DCBs or drug-eluting stents are able to suppress neointimal hyperplasia, the main cause of restenosis. This article reviews the results of DCB treatments of femoropopliteal and infrapopliteal lesions in comparison to standard angioplasty with uncoated balloons. A systematic literature search was performed in 1) medical journals (ie, MEDLINE), 2) international registers for clinical studies (ie, www.clinicaltrials.gov), and 3) abstracts of scientific sessions. Several controlled randomized trials with follow-up periods of up to 5 years demonstrated the efficacy of paclitaxel –DCB technology. However, calcified lesions seem to affect the efficacy of DCB. Combinations of preconditioning methods with DCBs showed promising results. Although the mechanical abrasion of calcium via atherectomy or laser ablation showed favorable periprocedural results, the long-term impact on restenosis and clinical outcome has to be demonstrated. Major advantages of the DCBs are the rapid delivery of drug at uniform concentrations with a single dose, their efficacy in areas wherein stents have been contraindicated until now (ie, bifurcation, ostial lesions), and in leaving no stent scaffold behind. Reinterventions are easier to perform because DCBs leave no metal behind. Various combinations of DCBs with other treatment modalities may prove to be viable options in future. The follow-up results of clinical studies will evaluate the long

  7. Intravascular ultrasound imaging of peripheral arteries as an adjunct to balloon angioplasty and atherectomy.

    Science.gov (United States)

    Korogi, Y; Hirai, T; Takahashi, M

    1996-01-01

    This article reviews many of the applications of intravascular ultrasound (US) imaging for peripheral arterial diseases. In vitro studies demonstrate an excellent correlation between ultrasound measurements of lumen and plaque cross-sectional area compared with histologic sections. In vivo clinical studies reveal the enhanced diagnostic capabilities of this technology compared with angiography. Intravascular US imaging can provide valuable information on the degree, eccentricity, and histologic type of stenosis before intervention, and on the morphological changes in the arterial wall and the extent of excision after intervention. Intravascular US may also serve as a superior index for gauging the diameter of balloon, stent, laser probe, and/or atherectomy catheter appropriate for a proposed intervention. Significant new insights into the mechanisms of balloon angioplasty and atherectomy have been established by intravascular US findings. Intravascular US imaging has been shown to be a more accurate method than angiography for determining the cross-sectional area of the arterial lumen, and for assessing severity of stenosis. Quantitative assessment of the luminal cross-sectional area after the balloon dilatation should be more accurate than angiography as intimal tears or dissections produced by the dilatation may not be accurately evaluated with angiography. At the present time, intravascular US is still a controversial imaging technique. Outcome studies are currently being organized to assess the clinical value and cost effectiveness of intravascular ultrasound in the context of these interventional procedures. PMID:8653738

  8. Deep sea water prevents balloon angioplasty-induced hyperplasia through MMP-2: an in vitro and in vivo study.

    Directory of Open Access Journals (Sweden)

    Pei-Chuan Li

    Full Text Available Major facts about the development of restenosis include vascular smooth muscle cells (VSMCs proliferation and migration. A previous study showed that in vitro treatment with magnesium chloride has the potential to affect the proliferation and migration of VSMCs. Magnesium is the major element in deep sea water (DSW and is a biologically active mineral. It is unclear whether DSW intake can prevent abnormal proliferation and migration of VSMCs as well as balloon angioplasty-induced neointimal hyperplasia. Thus, we attempted to evaluate the anti-restenotic effects of DSW and its possible molecular mechanisms. Several concentrations of DSW, based on the dietary recommendations (RDA for magnesium, were applied to a model of balloon angioplasty in SD rats. The results showed that DSW intake markedly increased magnesium content within the vascular wall and reduced the development of neointimal hyperplasia. The immunohistochemical analysis also showed that the expression of proteins associated with cell proliferation and migration were decreased in the balloon angioplasty groups with DSW supplement. Furthermore, in vitro treatment with DSW has a dose-dependent inhibitory effect on serum-stimulated proliferation and migration of VSMCs, whose effects might be mediated by modulation of mitogen-activated protein kinase (MAPK signaling and of the activity of matrix metalloproteinase-2 (MMP-2. Our study suggested that DSW intake can help prevent neointimal hyperplasia (or restenosis, whose effects may be partially regulated by magnesium and other minerals.

  9. Inferior knee arterial endoluminal angioplasty in treating severe lower limb ischemia though the DEEP balloon catheter

    International Nuclear Information System (INIS)

    Objective: To evaluate the efficacy of inferior knee arterial endoluminal angioplasty for treating severe lower limb ischemia with the use of the DEEP balloon catheter. Methods: Eleven patients (17 limbs) with severe ischemia of lower extremities from August 2007 to April 2008 were retrospectively studied. All involved limbs suffered from rest pain including 6 limbs (6/17)complicated with ulcer, 2 (2/17) with toe gangrene or 3 (3/17)with both of the complaints. ABI (Ankle bxancial index) were 0.2-0.5 and 0.51-0.7 in 12 limbs and 5 limbs respectively, with average value 0.47. Results: The success rate of operation was 100% (17/17). Pain relieved obviously in 13 limbs (13/17) and reduced in 2 limbs (2/17). 2 limbs (2/17) still suffered from pain and underwent upper-knee amputation and other 2 with ulcerations(2/ 17)were healed. 3 (3/17) with toe gangrene underwent partial foot amputation, 1 with dried gangrene remained unchanged and the other was lost. Another one showed ulcer healed and toe was lost. Increase of ABI was more than 0.5 in 10 limbs(10/17) and 0.3-0.5 in 5 limbs(5/17) with average value of 0.83. 10 patients with sixteen limbs were followed up in an average period of 4.3 months (1-9 months). Of the 15 immediate pain-relieved limbs, 12(12/15) limbs remained free of pain and pain recurred in 3 other limbs; and 2 of them with pain-reduced after PTA again; the other 1 underwent amputation, Average value of ABI was 0.70. Conclusions: Inferior arterial endoluminal angioplasty for the treatment of severe limb ischemia with application of the DEEP balloon catheter show high successful rate and short-term encouraging clinical results but mid-term and long-terms follow up should be undertaken for further investigation. (authors)

  10. Randomized Trial of the SMART Stent versus Balloon Angioplasty in Long Superficial Femoral Artery Lesions: The SUPER Study

    Energy Technology Data Exchange (ETDEWEB)

    Chalmers, Nicholas, E-mail: nicholas.chalmers@cmft.nhs.uk [Manchester Royal Infirmary, Department of Radiology (United Kingdom); Walker, Paul T. [James Cook University Hospital, Department of Radiology (United Kingdom); Belli, Anna-Maria [St. George' s Healthcare NHS Trust, Department of Radiology (United Kingdom); Thorpe, Anthony P. [Aberdeen Royal Infirmary, Department of Radiology (United Kingdom); Sidhu, Paul S. [King' s College Hospital, Department of Radiology (United Kingdom); Robinson, Graham [Hull Royal Infirmary, Department of Radiology (United Kingdom); Ransbeeck, Mariella van [Johnson and Johnson Medical NV/SA, Cordis (Belgium); Fearn, Steven A. [Johnson and Johnson Medical Ltd., Cordis (United Kingdom)

    2013-04-15

    To determine whether primary stenting reduces the rate of restenosis compared with balloon angioplasty alone in the endovascular treatment of long superficial femoral artery lesions; and to assess the effect of treatment on quality of life. A total of 150 patients with superior femoral artery occlusion or severe stenosis of 5-22 cm length from 17 UK centers were randomized to either primary stenting with the SMART stent or balloon angioplasty (i.e., percutaneous transluminal angioplasty, PTA). Bailout stent placement was permitted in case of inadequate result from PTA. The primary end point was restenosis measured by duplex ultrasound at 1 year. Quality-of-life assessments were performed by the EuroQol (EQ)-5D questionnaire. Mean lesion length was 123.0 mm in the stent group and 116.8 mm in the PTA group. A total of 140 (93.3 %) of 150 had total occlusions. At 12 months' follow-up, restenosis measured by Duplex ultrasound was not significantly different between the stent and PTA groups by intention-to-treat or as-treated analyses: 47.2 versus 43.5 % (p = 0.84) and 40.8 versus 46.7 % (p = 0.68), respectively. There were fewer target lesion revascularizations in patients randomized to stenting, but this did not reach statistical significance (12.5 vs. 20.8 %, p = 0.26). There was no difference in the rate of amputation. Patients in both groups reported improved quality of life. Primary stenting of long lesions in predominantly occluded superficial femoral arteries does not reduce the rate of binary restenosis compared with balloon angioplasty and bailout stenting. Both treatment strategies conferred a meaningful and sustained improvement to the quality of life of patients with severe superficial femoral artery disease.

  11. Neuroendocrine Responses to Transvascular Autonomic Modulation: A Modified Balloon Angioplasty in Multiple Sclerosis Patients.

    Science.gov (United States)

    Arata, M; Sternberg, Z

    2016-02-01

    Balloon angioplasty (BA) is a treatment modality to correct vascular lesions in multiple sclerosis (MS) patients, who present with chronic cerebrospinal venous insufficiency (CCSVI). We hypothesized that BA clinical benefits stems in part from improvement in cardiovascular autonomic nervous system (ANS) function. We adopted the Transvascular Autonomic Modulation (TVAM), as a modified BA technique, with the objective of further enhancing ANS functional activities. TVAM involved dilation of multiple vascular beds, including IJVs, azygos and renal veins, and application of manual compression. Since the ANS regulates the function of the hypothalamus pituitary (HPA) axis, we examined TVAM effects on HPA axis in MS patients, and determined the relationship between ANS function and HPA activity. The adrenocorticotropic hormone (ACTH) and cortisol serum levels, systolic and diastolic blood pressure (BP), and heart rate variability (HRV) parameters were measured before and 24 h after TVAM procedure in 72 MS patients. Baseline ACTH and cortisol serum levels were lower than normal ranges in 18% and 25% MS patients respectively. The intervention resulted in significant reductions in both ACTH and cortisol (pcounter to the stress-mediated increases in serum levels of these hormones, which are expected following an invasive procedure. The clinical implications of this unexpected response warrant further investigations. PMID:25789986

  12. The comparison a 16-year follow-up results of balloon angioplasty for aortic coarctation in children of different age groups: a single-center experience

    OpenAIRE

    Yakup Ergül; Kemal Nişli; Aygün Dindar; Rukiye Eker Ömeroğlu; Ümrah Aydoğan

    2011-01-01

    Objective: Pediatric patients with different age groups who underwent balloon angioplasty for aortic coarctation were evaluated for recoarctation, aneurysm, peripheral arterial injuries and concomitant diseases. Methods: From January 1994 to 2010, 80 patients with aortic coarctation (native/recoarctation) were evaluated, retrospectively. According to age at angioplasty, patients were divided into three groups: Group A (0-3 months, n=29, 25 male/4 female, average weight 4±1.2 kg), Group B (3-1...

  13. Low-pressure balloon angioplasty with adjuvant pharmacological therapy in patients with acute ischemic stroke caused by intracranial arterial occlusions

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, Raul G. [Massachusetts General Hospital, Harvard Medical School, Department of Radiology, Endovascular Neurosurgery/Interventional Neuroradiology Section, Boston, MA (United States); Massachusetts General Hospital, Harvard Medical School, Department of Neurosurgery, Endovascular Neurosurgery/Interventional Neuroradiology Section, Boston, MA (United States); Massachusetts General Hospital, Harvard Medical School, Department of Neurology, Neurocritical Care and Vascular Neurology Section, Boston, MA (United States); Massachusetts General Hospital, Boston, MA (United States); Schwamm, Lee H.; Buonanno, Ferdinando S.; Koroshetz, Walter J. [Massachusetts General Hospital, Harvard Medical School, Department of Neurology, Neurocritical Care and Vascular Neurology Section, Boston, MA (United States); Yoo, Albert J.; Rabinov, James D.; Pryor, Johnny C.; Hirsch, Joshua A. [Massachusetts General Hospital, Harvard Medical School, Department of Radiology, Endovascular Neurosurgery/Interventional Neuroradiology Section, Boston, MA (United States); Massachusetts General Hospital, Harvard Medical School, Department of Neurosurgery, Endovascular Neurosurgery/Interventional Neuroradiology Section, Boston, MA (United States)

    2008-04-15

    The use of coronary balloons in the cerebral vasculature is limited due to their poor trackability and increased risk of vessel injury. We report our experience using more compliant elastomer balloons for thrombus resistant to intraarterial (IA) pharmacological and mechanical thrombolysis in acute stroke. We retrospectively analyzed 12 consecutive patients with an occluded intracranial artery treated with angioplasty using a low-pressure elastomer balloon. Angiograms were graded according to the Thrombolysis in Cerebral Infarction (TICI) and Qureshi grading systems. Outcomes were categorized as independent (modified Rankin scale, mRS, score {<=}2), dependent (mRS score 3-5), or dead (mRS score 6). Included in the study were 12 patients (mean age 66{+-}17 years, range 31-88 years; mean baseline National Institutes of Health stroke scale score 17{+-}3, range 12-23). The occlusion sites were: internal carotid artery (ICA) terminus (five patients, including two concomitant cervical ICA occlusions), M1 segment (two patients), and basilar artery (two patients). Pharmacological treatment included intravenous (IV) t-PA only (two patients), IA urokinase only (nine patients), both IV t-PA and IA urokinase (one patient), and IV and/or IA eptifibatide (eight patients). Mean time to treatment was 5.9{+-}3.9 h (anterior circulation) and 11.0{+-}7.2 h (posterior circulation). Overall recanalization rate (TICI grade 2/3) was 91.6%. Procedure-related morbidity occurred in one patient (distal posterior inferior cerebellar artery embolus). There were no symptomatic hemorrhages. Outcomes at 90 days were independent (five patients), dependent (three patients) and dead (four patients, all due to progression of stroke with withdrawal of care). Angioplasty of acutely occluded intracranial arteries with low-pressure elastomer balloons results in high recanalization rates with an acceptable degree of safety. Prior use of thrombolytics may increase the chances of recanalization, and

  14. Absence of Bacteria on Coronary Angioplasty Balloons from Unselected Patients: Results with Use of a High Sensitivity Polymerase Chain Reaction Assay

    Science.gov (United States)

    Hansen, Gorm Mørk; Nilsson, Martin; Nielsen, Claus Henrik; Holmstrup, Palle; Helqvist, Steffen; Tolker-Nielsen, Tim; Givskov, Michael; Hansen, Peter Riis

    2015-01-01

    Periodontitis is a chronic, bacterially-induced inflammatory disease of the tooth-supporting tissues, which may result in transient bacteremia and a systemic inflammatory response. Periodontitis is associated with coronary artery disease independently of established cardiovascular risk factors, and translocation of bacteria from the oral cavity to the coronary arteries may play a role in the development of coronary artery disease. Very few studies have used angioplasty balloons for in vivo sampling from diseased coronary arteries, and with varying results. Therefore, the aim of this study was to assess if bacterial DNA from primarily oral bacteria could be detected on coronary angioplasty balloons by use of an optimized sampling process combined with an internally validated sensitive polymerase chain reaction (PCR) assay. Coronary angioplasty balloons and control samples from a total of 45 unselected patients with stable angina, unstable angina/non-ST elevation myocardial infarction, and ST-elevation myocardial infarction (n = 15 in each group) were collected and analyzed using a PCR assay with high sensitivity and specificity for 16S rRNA genes of the oral microbiome. Despite elimination of extraction and purification steps, and demonstration of sensitivity levels of 25–125 colony forming units (CFU), we did not detect bacterial DNA from any of the coronary angioplasty balloons. A subsequent questionnaire indicated that the prevalence of periodontitis in the study cohort was at least 39.5%. Although coronary angioplasty balloons are unlikely to be useful for detection of bacteria with current PCR techniques in unselected patients with coronary artery disease, more studies are warranted to determine the extent to which bacteria contribute to atherosclerosis and its clinical manifestations and whether the presence of bacteria in the arteries is a transient phenomenon. PMID:26695491

  15. Low-pressure balloon angioplasty with adjuvant pharmacological therapy in patients with acute ischemic stroke caused by intracranial arterial occlusions

    International Nuclear Information System (INIS)

    The use of coronary balloons in the cerebral vasculature is limited due to their poor trackability and increased risk of vessel injury. We report our experience using more compliant elastomer balloons for thrombus resistant to intraarterial (IA) pharmacological and mechanical thrombolysis in acute stroke. We retrospectively analyzed 12 consecutive patients with an occluded intracranial artery treated with angioplasty using a low-pressure elastomer balloon. Angiograms were graded according to the Thrombolysis in Cerebral Infarction (TICI) and Qureshi grading systems. Outcomes were categorized as independent (modified Rankin scale, mRS, score ≤2), dependent (mRS score 3-5), or dead (mRS score 6). Included in the study were 12 patients (mean age 66±17 years, range 31-88 years; mean baseline National Institutes of Health stroke scale score 17±3, range 12-23). The occlusion sites were: internal carotid artery (ICA) terminus (five patients, including two concomitant cervical ICA occlusions), M1 segment (two patients), and basilar artery (two patients). Pharmacological treatment included intravenous (IV) t-PA only (two patients), IA urokinase only (nine patients), both IV t-PA and IA urokinase (one patient), and IV and/or IA eptifibatide (eight patients). Mean time to treatment was 5.9±3.9 h (anterior circulation) and 11.0±7.2 h (posterior circulation). Overall recanalization rate (TICI grade 2/3) was 91.6%. Procedure-related morbidity occurred in one patient (distal posterior inferior cerebellar artery embolus). There were no symptomatic hemorrhages. Outcomes at 90 days were independent (five patients), dependent (three patients) and dead (four patients, all due to progression of stroke with withdrawal of care). Angioplasty of acutely occluded intracranial arteries with low-pressure elastomer balloons results in high recanalization rates with an acceptable degree of safety. Prior use of thrombolytics may increase the chances of recanalization, and glycoprotein IIb

  16. Ultrasonography-guided Balloon Angioplasty in an Autogenous Arteriovenous Fistula: Preliminary Results

    International Nuclear Information System (INIS)

    Percutaneous trasnluminal angioplasty (PTA) of a malfunctioning arteriovenous fistula (AVF) in hemodialysis patients requires the use of contrast angiography and fluoroscopy guidance. We attempted to perform this procedure under duplex ultrasound guidance to reduce the amount of contrast agent administered and to reduce the radiation dose during the interventional procedures. From September 2006 to February 2007, 45 patients received interventional treatment due to malfunctioning hemodialysis access in our hospital. Among the patients, we selected 10 patients diagnosed with stenosis of an autogenous arteriovenous fistula based on a physical examination. There were six males and four females aged 51-78 years (mean age, 59 years). Seven of these patients had a Brescia-Cinimo type fistula and three patients had a basilic vein transposition. All procedures were performed in the angiography suite. All procedures that required angioplasty were performed under duplex ultrasound guidance and then contrast angiography was performed to confirm the final patency of the vessels. Conventional angioplasty was also performed under fluoroscopy guidance for any lesions that required an additional angioplasty. The volume flow before and after the PTA and procedure time were recorded. Clinical success was defined as the performance of one or more successful hemodialysis sessions after treatment. Eight of ten patients did not require an additional angioplasty by conventional angiography after the duplex- guided angioplasty. One case showed recoiling of stenosis after the duplex-guided PTA and another case was missed at duplex scanning due to the extremely short nature of the recoiling of stenosis. The mean volume flow before and after PTA was 167 ml/min (range, 80-259 ml/min) and 394.2 ml/min (range, 120-586 ml/min), respectively. No complications associated with the duplex-guide procedure occurred. In nine cases, PTA enabled hemodialysis to be conducted more than one time. In one

  17. Ultrasonography-guided Balloon Angioplasty in an Autogenous Arteriovenous Fistula: Preliminary Results

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Chang [Daejeon St Mary' s Hospital, Daejeon (Korea, Republic of); Cho, June Sik [Chungnam National University College of Medicine, Daejeon (Korea, Republic of)

    2007-09-15

    Percutaneous trasnluminal angioplasty (PTA) of a malfunctioning arteriovenous fistula (AVF) in hemodialysis patients requires the use of contrast angiography and fluoroscopy guidance. We attempted to perform this procedure under duplex ultrasound guidance to reduce the amount of contrast agent administered and to reduce the radiation dose during the interventional procedures. From September 2006 to February 2007, 45 patients received interventional treatment due to malfunctioning hemodialysis access in our hospital. Among the patients, we selected 10 patients diagnosed with stenosis of an autogenous arteriovenous fistula based on a physical examination. There were six males and four females aged 51-78 years (mean age, 59 years). Seven of these patients had a Brescia-Cinimo type fistula and three patients had a basilic vein transposition. All procedures were performed in the angiography suite. All procedures that required angioplasty were performed under duplex ultrasound guidance and then contrast angiography was performed to confirm the final patency of the vessels. Conventional angioplasty was also performed under fluoroscopy guidance for any lesions that required an additional angioplasty. The volume flow before and after the PTA and procedure time were recorded. Clinical success was defined as the performance of one or more successful hemodialysis sessions after treatment. Eight of ten patients did not require an additional angioplasty by conventional angiography after the duplex- guided angioplasty. One case showed recoiling of stenosis after the duplex-guided PTA and another case was missed at duplex scanning due to the extremely short nature of the recoiling of stenosis. The mean volume flow before and after PTA was 167 ml/min (range, 80-259 ml/min) and 394.2 ml/min (range, 120-586 ml/min), respectively. No complications associated with the duplex-guide procedure occurred. In nine cases, PTA enabled hemodialysis to be conducted more than one time. In one

  18. Balloon angioplasty of popliteal and crural arteries in elderly with critical chronic limb ischemia

    International Nuclear Information System (INIS)

    Objective: Elderly patients with extensive infrainguinal peripheral vascular disease and critical chronic limb ischemia (CCLI) are poor surgical candidates. Our purpose was to evaluate angiographic and clinical results of popliteal, infrapopliteal, and multi-level disease percutaneous transluminal angioplasty (PTA) in such patients. Design: Retrospective study of angiographic and clinical files in selected group. Materials and methods: Between 1996 and 2002, 38 elderly patients aged 80-94 years old (mean age 83.3) with critical leg ischemia were treated with PTA. All patients were at high surgical risk. 31/38 (81.5%) patients had chronic non-healing wounds, and 14/38 (37%) had multi-level disease of superficial femoral, popliteal and crural arteries. One hundred and two lesions were treated by angioplasty. Immediate angiographic and 1 year clinical results were retrospectively analyzed. Results: The overall procedural success rate was 32/38 (84.2%). There were three major complications (7.9%), but no deaths, and three technical failures, all were of infrapopliteal lesions. After 1 year, 27 patients could be followed, five patients died during the first year of unrelated causes. Twenty-three patients (85.2%), were clinically re-occluded within 1 year, but complete and partial wound healing was achieved in 80% (16/20) and rest pain improvement in 57% (4/7), so that overall limb salvage was 74% (20/27). Conclusions: Elderly patients with multi-level CCLI have a short patency term following angioplasty of 14.8% after 1 year. Nevertheless, this temporary vascular patency enables wound healing or improvement in 74% of these patients, thus such endovascular interventions are recommended in this age group

  19. Observation and nursing of complications due to high re-perfusion injury occurring after balloon angioplasty for diabetic vascular diseases of lower extremity

    International Nuclear Information System (INIS)

    Objective: To evaluate the symptomatic nursing in treating the complications caused by high re-perfusion which develops after balloon angioplasty for the treatment of diabetic vascular diseases of lower extremity. Methods: Eighteen patients with lower limb ischemia caused by diabetes mellitus developed high re-perfusion injury complications after receiving balloon angioplasty. The patients were randomly and equally divided into study group and control group. The special nursing measures designed by the author's department, including raising the diseased lower limb, enforcing the flexion and extension movement of the leg, cold compress, wound exposure, etc. were carried out for patients of study group, while no special nursing measures were adopted for patients of control group. The clinical results, such as limb pain, swelling and subcutaneous petechia after re-perfusion injury, were evaluated and compared between two groups. Results: After the treatment, the limb pain, swelling and subcutaneous petechia due to high re-perfusion injury in study group were relieved more markedly than that in control group, the difference in evaluation score between two groups was statistically significant (P<0.01). Conclusion: The special symptomatic nursing measures are very effective in relieving the high re-perfusion injury after balloon angioplasty for the treatment of diabetic lower limb ischemia. (authors)

  20. Cephalic arch stenosis in autogenous brachiocephalic hemodialysis fistulas: results of cutting balloon angioplasty

    DEFF Research Database (Denmark)

    Heerwagen, Søren Thorup; Lönn, Lars; Schroeder, Torben V; Hansen, Marc Allan

    2010-01-01

    Cephalic arch stenosis is a known cause of hemodialysis access failure in patients with brachiocephalic fistulas (BCFs). Outcomes of endovascular treatment are affected by resistance of the stenosis to balloon dilation, a high vein rupture rate and the development of early restenosis. The purpose...

  1. Balloon angioplasty of infrapopliteal artery in chronic lower limb ischemia with diabetes

    International Nuclear Information System (INIS)

    Objective: To evaluate the technique, successful rate and perioperative complications together with the therapy and prevention of using PTA in treating diabetic patients with infrapopliteal arterial diseases. Methods: Angiographic and clinical data of 27 patients with diabetic lower limb ischemia treated by PTA from January 2006 to May 2007 were retrospectively reviewed. Rutherf0rd-Becker categories and ankle- brachial index(ABI)were evaluated before and after the treatment. The effects were compared between different lesion types (stenosis or occlusion)and between different ways of balloon technique. The complications were also analyzed, together with the primary, discussion of the therapy and prevention. Results: 24 patients showed improvement of ischemic symptoms, and 3 cases fell in failure. The intra-procedural main complications included acute thrombosis, vascular wall perforation, distal emboli resulting from plaque falling off and dissection. There were statistically significant differences between the effects of two type lesions and between different balloon methods. Conclusions: 1. The condition of lower limb arteries should be assessed carefully before operation. 2. PTA shows safe and good clinical result and ought to be recommended in treating diabetic patients with peripheral arterial diseases, especially the lower extremity ischemia. (authors)

  2. Preparation and characterisation of polyamide 11/montmorillonite (MMT) nanocomposites for use in angioplasty balloon applications

    Energy Technology Data Exchange (ETDEWEB)

    Halim, Khairul Anwar A. [Department of Polymer Engineering, Athlone Institute of Technology, Athlone (Ireland); School of Materials Engineering, Universiti Malaysia Perlis, Perlis (Malaysia); Farrell, Joseph B. [Department of Polymer Engineering, Athlone Institute of Technology, Athlone (Ireland); Kennedy, James E., E-mail: jkennedy@ait.ie [Department of Polymer Engineering, Athlone Institute of Technology, Athlone (Ireland)

    2013-12-16

    With increased demands on catheter balloon functionality, there is an emphasis to blend new materials which can improve mechanical performance. Polymer nanocomposites were prepared by melt blending polyamide 11 (PA 11) with organically modified montmorillonite nanoclay. The effects of incorporating the nanoclay on the short-term mechanical properties of PA 11 were assessed using a design of experiments (DoEs) approach. X-ray diffraction (XRD), transmission electron microscopy (TEM), differential scanning calorimetry (DSC) and dynamic mechanical thermal analysis techniques (DMA) were used to characterise the morphology of the nanocomposites. Design of experiments studies revealed that the optimum nanocomposites properties can be achieved by carefully controlling the melt compounding parameters. XRD and TEM data proved that exfoliated clay morphologies existed within the matrix at low clay loading (2%). Whereas the interaction between the polymer matrix and nanoclay was quantified in the DMA spectra, showed a significant increase in storage modulus (up to 80%). The reinforcing effect of nanoclay within the PA 11 was further investigated using mechanical testing, where significant increases in the ultimate tensile strength and strain at break of reinforced tri-layer balloon tubing were observed. - Highlights: • TEM reveals the coexistence of exfoliated and intercalated nanostructures. • Isothermal crystallisation studies found that the nano-clays reduced the crystallisation time. • Significant increase in the storage modulus was due to the reinforcing effect of the nano-clay platelets. • It was observed that the activation energy values decreased due to the presence of nanoclay.

  3. Endovascular recanalization of acute intracranial vertebrobasilar artery occlusion using local fibrinolysis and additional balloon angioplasty

    International Nuclear Information System (INIS)

    Vertebrobasilar artery occlusion (VBO) produces high mortality and morbidity due to low recanalization rate utilization in endovascular therapy. The use of percutaneous transluminal angioplasty (PTA) to improve recanalization rate additional to local intra-arterial fibrinolysis (LIF) was investigated in this study. Results obtained following recanalization therapy in acute intracranial VBO are reported. Eighteen consecutive patients with acute VBO underwent LIF with or without PTA, from August 2000 to May 2006. Eight patients were treated using LIF alone, and ten required additional PTA. Rate of recanalization, neurological status before treatment, and clinical outcomes were evaluated. Of 18 patients, 17 achieved recanalization. One procedure-related complication of subarachnoid hemorrhage occurred. Overall survival rate was 94.4% at discharge. Seven patients achieved good outcomes [modified Rankin scale (mRS) 0-2], and the other 11 had poor outcomes (mRS 3-6). Five of six patients who scored 9-14 on the Glasgow Coma Scale (GCS) before treatment displayed good outcomes, whereas ten of 12 patients who scored 3-8 on the GCS showed poor outcomes. GCS prior to treatment showed a statistically significant correlation to outcomes (p < 0.05). Moreover, the National Institutes of Health Stroke Scale (NIHSS) before treatment correlated well with mRS (correlation coefficient 0.487). No statistical difference between the good and poor outcome groups was observed for the duration of symptoms, age, etiology, and occlusion site. Endovascular recanalization can reduce mortality and morbidity of acute VBO. Good GCS and NIHSS scores prior to treatment can predict the efficacy of endovascular recanalization. (orig.)

  4. Endovascular recanalization of acute intracranial vertebrobasilar artery occlusion using local fibrinolysis and additional balloon angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwagi, Junji; Okahara, Mika [Shinbeppu Hospital, Department of Radiology, Beppu, Oita (Japan); Kiyosue, Hiro; Tanoue, Shuichi; Sagara, Yoshiko; Mori, Hiromu [Oita University Faculty of Medicine, Department of Radiology, Yufu, Oita (Japan); Hori, Yuzo [Nagatomi Neurosurgical Hospital, Department of Radiology, Oita, Oita (Japan); Abe, Toshi [Kurume University School of Medicine, Department of Radiology, Kurume, Fukuoka (Japan)

    2010-05-15

    Vertebrobasilar artery occlusion (VBO) produces high mortality and morbidity due to low recanalization rate utilization in endovascular therapy. The use of percutaneous transluminal angioplasty (PTA) to improve recanalization rate additional to local intra-arterial fibrinolysis (LIF) was investigated in this study. Results obtained following recanalization therapy in acute intracranial VBO are reported. Eighteen consecutive patients with acute VBO underwent LIF with or without PTA, from August 2000 to May 2006. Eight patients were treated using LIF alone, and ten required additional PTA. Rate of recanalization, neurological status before treatment, and clinical outcomes were evaluated. Of 18 patients, 17 achieved recanalization. One procedure-related complication of subarachnoid hemorrhage occurred. Overall survival rate was 94.4% at discharge. Seven patients achieved good outcomes [modified Rankin scale (mRS) 0-2], and the other 11 had poor outcomes (mRS 3-6). Five of six patients who scored 9-14 on the Glasgow Coma Scale (GCS) before treatment displayed good outcomes, whereas ten of 12 patients who scored 3-8 on the GCS showed poor outcomes. GCS prior to treatment showed a statistically significant correlation to outcomes (p < 0.05). Moreover, the National Institutes of Health Stroke Scale (NIHSS) before treatment correlated well with mRS (correlation coefficient 0.487). No statistical difference between the good and poor outcome groups was observed for the duration of symptoms, age, etiology, and occlusion site. Endovascular recanalization can reduce mortality and morbidity of acute VBO. Good GCS and NIHSS scores prior to treatment can predict the efficacy of endovascular recanalization. (orig.)

  5. Utility of birefringence changes due to collagen thermal denaturation rate process analysis: vessel wall temperature estimation for new short term heating balloon angioplasty

    Science.gov (United States)

    Kaneko, Kenji; Shimazaki, Natsumi; Gotoh, Maya; Nakatani, Eriko; Arai, Tsunenori

    2007-02-01

    Our photo thermal reaction heating architecture balloon realizes less than 10 s short term heating that can soften vessel wall collagen without damaging surrounding tissue thermally. New thermal balloon angioplasty, photo-thermo dynamic balloon angioplasty (PTDBA) has experimentally shown sufficient opening with 2 atm low pressure dilation and prevention of chronic phase restenosis and acute phase thrombus in vivo. Even though PTDBA has high therapeutic potential, the most efficient heating condition is still under study, because relationship of treatment and thermal dose to vessel wall is not clarified yet. To study and set the most efficient heating condition, we have been working on establishment of temperature history estimation method from our previous experimental results. Heating target of PTDBA, collagen, thermally denatures following rate process. Denaturation is able to be quantified with measured collagen birefringence value. To express the denaturation with equation of rate process, the following ex vivo experiments were performed. Porcine extracted carotid artery was soaked in two different temperature saline baths to enforce constant temperature heating. Higher temperature bath was set to 40 to 80 degree Celsius and soaking duration was 5 to 40 s. Samples were observed by a polarizing microscope and a scanning electron microscope. The birefringence was measured by polarizing microscopic system using Brace-Koehler compensator 1/30 wavelength. The measured birefringence showed temperature dependency and quite fit with the rate process equation. We think vessel wall temperature is able to be estimated using the birefringence changes due to thermal denaturation.

  6. Safety and efficacy of limus-eluting stents and balloon angioplasty for sirolimus-eluting in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideaki [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Mahmoudi, Michael [University of Surrey, Guildford Road, Surrey, GU2-7XH (United Kingdom); Kitabata, Hironori; Torguson, Rebecca; Chen, Fang; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D. [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Waksman, Ron, E-mail: ron.waksman@medstar.net [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States)

    2015-03-15

    Objectives: The aim of this study was to compare the safety and efficacy of everolimus-eluting stent (EES), sirolimus-eluting stent (SES), and plain old balloon angioplasty (POBA) for the treatment of SES in-stent restenosis (S-ISR). Background: The optimal treatment for drug-eluting in-stent restenosis remains controversial. Methods: The study cohort comprised 310 consecutive patients (444 lesions) who presented with S-ISR to our institution and underwent treatment with EES (43 patients), SES (102), or POBA (165). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac event (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors for coronary artery disease except for smoking. The 1-year analyzed clinical parameters were similar in the three groups: MACE (EES = 14%, SES = 18%, POBA = 20%; p = 0.65), death (EES = 2.3%, SES = 6.2%, POBA = 6.1%; p = 0.61), MI (EES = 4.8%, SES = 2.1%, POBA = 2.5%; p = 0.69), TLR (EES = 11.9%, SES = 12.1%, POBA = 24%; p = 0.78), and TVR (EES = 11.9%, SES = 24.8%, POBA = 22.2%; p = 0.23). There were no cases of definite ST. MACE-free rate was significantly lower in patients with recurrent in-stent restenosis (log-rank p = 0.006). Presentation with acute MI, number of treated lesions and a previous history of MI were found to be independent predictors of MACE. Conclusions: In patients presenting with S-ISR, treatment with implantation of an EES, SES, or POBA is associated with similar clinical outcomes. Patients presenting with recurrent ISR may have a poorer clinical outcome.

  7. Monitoring of gadolinium-BOPTA uptake into the vessel wall during magnetic resonance (MR)-guided angioplasty of the peripheral arteries with a paclitaxel/gadolinium-BOPTA-coated balloon. An experimental study at 3 Tesla

    International Nuclear Information System (INIS)

    Purpose: The success of paclitaxel distribution within the vessel wall during paclitaxel-coated balloon angioplasty to prevent restenosis cannot be monitored under X-ray guidance. The aim of this pilot study was to demonstrate the feasibility of monitoring Gadolinium-BOPTA delivery within the vessel wall during magnetic resonance (MR)-guided paclitaxel/Gadolinium-BOPTA-coated balloon angioplasty of the peripheral arteries. Materials and methods: 6 pigs (47 ± 2 kg) were investigated. All experiments were performed using a 3 Tesla MR scanner. MR-guided bilaterial angioplasty of the iliac arteries was performed using a paclitaxel/MR contrast agent-coated balloon catheter. The feasibility of monitoring the delivery of Gadolinium-BOPTA to the vessel was assessed in 4 animals. In two additional animals, bilateral stenosis was surgically induced in the iliac arteries. Delivery of paclitaxel to the vessel wall was monitored using a 3 D T1-weighted gradient echo (GE) sequence for delineation of the vessel wall. Normalized signal intensity (SI) of the vessel wall was measured before and repeatedly after the intervention for 45 min. in all animals. Results: Paclitaxel/gadolinium-BOPTA-coated balloon angioplasty was successfully accomplished in all iliac arteries (n = 12). In animals with stenosis MR-angiography demonstrated successful dilatation (n = 4). The normalized SI of the vessel wall on T1-weighted GE images significantly increased after the intervention in all animals with and without stenosis for more than 45 min. (p < 0.001). Conclusion: Monitoring of Gadolinium-BOPTA into the vessel wall during MR-guided coated balloon angioplasty is feasible. This is a first step towards providing a tool for the online control of homogenous drug delivery after paclitaxel-coated balloon angioplasty. (orig.)

  8. Monitoring of gadolinium-BOPTA uptake into the vessel wall during magnetic resonance (MR)-guided angioplasty of the peripheral arteries with a paclitaxel/gadolinium-BOPTA-coated balloon. An experimental study at 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Neizel, M.; Kelm, M. [University Hospital Duesseldorf (Germany). Dept. of Cardiology, Pneumology and Angiology; Ruebben, A.; Weiss, N. [Aachen Resonance, Aachen (Germany); Guenther, R.W. [University Hospital Aachen (Germany). Dept. of Radiology; Krombach, G.A. [University Hospital Giessen (Germany). Dept. of Radiology

    2014-04-15

    Purpose: The success of paclitaxel distribution within the vessel wall during paclitaxel-coated balloon angioplasty to prevent restenosis cannot be monitored under X-ray guidance. The aim of this pilot study was to demonstrate the feasibility of monitoring Gadolinium-BOPTA delivery within the vessel wall during magnetic resonance (MR)-guided paclitaxel/Gadolinium-BOPTA-coated balloon angioplasty of the peripheral arteries. Materials and methods: 6 pigs (47 ± 2 kg) were investigated. All experiments were performed using a 3 Tesla MR scanner. MR-guided bilaterial angioplasty of the iliac arteries was performed using a paclitaxel/MR contrast agent-coated balloon catheter. The feasibility of monitoring the delivery of Gadolinium-BOPTA to the vessel was assessed in 4 animals. In two additional animals, bilateral stenosis was surgically induced in the iliac arteries. Delivery of paclitaxel to the vessel wall was monitored using a 3 D T1-weighted gradient echo (GE) sequence for delineation of the vessel wall. Normalized signal intensity (SI) of the vessel wall was measured before and repeatedly after the intervention for 45 min. in all animals. Results: Paclitaxel/gadolinium-BOPTA-coated balloon angioplasty was successfully accomplished in all iliac arteries (n = 12). In animals with stenosis MR-angiography demonstrated successful dilatation (n = 4). The normalized SI of the vessel wall on T1-weighted GE images significantly increased after the intervention in all animals with and without stenosis for more than 45 min. (p < 0.001). Conclusion: Monitoring of Gadolinium-BOPTA into the vessel wall during MR-guided coated balloon angioplasty is feasible. This is a first step towards providing a tool for the online control of homogenous drug delivery after paclitaxel-coated balloon angioplasty. (orig.)

  9. Local Administration of NF-κ B Decoy Oligonucleotides to Prevent Restenosis after Balloon Angioplasty: An Experimental Study in New Zealand White Rabbits

    International Nuclear Information System (INIS)

    Purpose. To evaluate the efficacy of NF-κ B oligonucleotides (ODN) administered by local administration with the channeled balloon catheter to prevent restenosis after balloon angioplasty in restenotic iliac arteries of New Zealand white rabbits. Materials and Methods. In vitro, 8000 rabbit vascular smooth muscle cells (rVSMC) where transfected with a liposomal carrier (TfX50) with 100 ng of decoy and scrambled ODN. Inhibition of proliferation was measured using a MTT assay after 24 hours in comparison to control. In vivo, 22 male New Zealand White rabbits were fed a 1% cholesterol diet and received denudation of both common iliac arteries with a 3 mm balloon catheter to induce an arterial stenosis. Four weeks after stenosis induction, local application of NF-κ B in two different concentrations (1 μg: n = 14; 10 μg: n = 8) was performed randomly on one common iliac artery. Scrambled oligonucleotides without specific binding capacities were injected into the contralateral side. The channeled balloon catheter allows simultaneous balloon dilation (8 atm) of the stenosis and local application of a drug solution (2 atm). Four weeks after local drug delivery the animals were killed and the vessels were excised and computerized morphometric measurements were performed. Results. NF-κ B decoy ODN but not scrambled ODN inhibited proliferation of rVSMC in vitro. Following local ODN application in the animals, no acute vascular complications were seen. NF-κ B ODN resulted in a statistically non significant reduction of neointimal area compared to the control group. The neointimal area was 0.97 mm2 using 1 μg NF-κ B ODN compared to 0.98 mm2 in the control group. The higher dose resulted in a neointimal area of 0.97 mm2 compared to 1.07mm2 at the control side. Conclusions. Local drug delivery of NF-κ B ODN using the 'channeled balloon' catheter could not reduce neointimal hyperplasia in stenostic rabbit iliac arteries. Application modalities have to be improved to

  10. Infrapopliteal angioplasty with a long over-the-wire balloon for the treatment of severe limb ischemia in diabetic patients: a retrospective analysis

    International Nuclear Information System (INIS)

    Objective: To retrospectively evaluate the safety and efficacy of percutaneous transluminal angioplasty (PTA) by using a long over-the-wire (OTW) balloon for the treatment of severe limb ischemia in diabetic patients. Methods: During the period from April 2007 to March 2008, infrapopliteal PTA by using a long OTW balloon was performed in 34 patients. The patients, with a mean age of (71.8±7.4) years, had 53 affected limbs with a total of 119 vascular lesions. All patients presented with a chief complaint of limb ischemic symptoms. Angiographic findings were retrospectively analysed and the lesions were categorized according to the length and severity. The mean follow-up period was (7.4±2.6) months. Magnetic resonance angiography (MRA) of the lower limb was conducted every three months during the follow-up period, and the clinical data were collected and analysed. Results: Infrapopliteal PTA by using a long OTW balloon was successfully carried out in 92.4% of vascular lesions (110/119). Ankel-brachial index (ABI) and transcutaneous oxygen tension (TcPO2) were improved from preoperative (0.50±0.18) and (18.85±12.08) mmHg to postoperative (0.81±0.12) and (39.85±12.67) mmHg, respectively. At the end of follow-up, 29 patients maintained a stable outcome. Recurrence of symptoms were seen in five patients, and three of them had to receive a second PTA. Although two major amputations and four minor amputations had to be done, 94% limb salvage rate and 59% patency rate were obtained. Conclusion: Infrapopliteal PTA by using a long OTW balloon for the treatment of severe limb ischemia in diabetic patients, is clinically feasible and safe. Its midterm outcome is satisfactory and encouraging although its long-term effect needs to be evaluated with further study. (authors)

  11. Unintended Thermal Injuries from Radiofrequency Ablation: Organ Protection with an Angioplasty Balloon Catheter in an Animal Model

    Directory of Open Access Journals (Sweden)

    Martha-Grace Knuttinen

    2014-01-01

    Full Text Available Objectives: The aim of this study was to investigate a novel approach of using a balloon catheter as a protective device to separate liver from the diaphragm or nearby bowel during radiofrequency ablation (RFA of hepatic dome tumors in an animal model. Materials and Methods: All experimental procedures were approved by animal Institutional Review Board. Using a 3 cm RF needle electrode, 70 hepatic ablation zones were created using ultrasound in 7 pigs. 50 lesions were created using balloon interposition between liver and diaphragm; 20 lesions were created using the balloon device interposed posteriorly between liver and bowel. Additional 21 control lesions were performed. Animals were sacrificed immediately; diaphragm and bowel were then visually inspected and sectioned. Diaphragmatic and bowel injury was then classified according to the depth of thickness. Results: Control lesions caused full thickness injury, either to diaphragm or bowel. During ablation of lesions with balloon interposition, there was significantly less diaphragmatic injury, P < 0.001 and less bowel injury, P < 0.01. Conclusion: Using balloon interposition as a protective device has advantages over previous saline infusion or CO 2 insufflation, providing a safe way to expand percutaneous RFA of liver tumors located on the undersurface of the diaphragm. In addition, this method may be used in protection of other organs adjacent to areas being ablated.

  12. Drug-eluting versus plain balloon angioplasty for the treatment of failing dialysis access: Final results and cost-effectiveness analysis from a prospective randomized controlled trial (NCT01174472)

    Energy Technology Data Exchange (ETDEWEB)

    Kitrou, Panagiotis M., E-mail: panoskitrou@gmail.com [Department of Interventional Radiology, Patras University Hospital, School of Medicine, Rion 26504 (Greece); Katsanos, Konstantinos [Department of Interventional Radiology, Guy' s and St. Thomas’ Hospitals, NHS Foundation Trust, King' s Health Partners, London SE1 7EH (United Kingdom); Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris [Department of Interventional Radiology, Patras University Hospital, School of Medicine, Rion 26504 (Greece)

    2015-03-15

    Highlights: •1-Year target lesion primary patency significantly higher after PCB application compared to plain balloon angioplasty in the failing dialysis access. •Significant difference in favor of PCB in cumulative primary patency of AVGs at 1 year. •No significant difference in cumulative primary patency of AVFs treated with PCB at 1 year. •Cost effectiveness analysis performed. •Paclitaxel-coated balloon angioplasty proves to be a cost-effective option for treating dialysis access. -- Abstract: Objective: To report the final results and cost-effectiveness analysis of a prospective randomized controlled trial investigating drug-eluting balloon (DEB) versus plain balloon angioplasty (BA) for the treatment of failing dialysis access ( (NCT01174472)). Methods: 40 patients were randomized to angioplasty with either DEB (n = 20) or BA (n = 20) for treatment of significant venous stenosis causing a failing dialysis access. Both arteriovenous fistulas (AVF) and synthetic arteriovenous grafts (AVG) were included. Angiographic follow up was scheduled every two months. Primary endpoints were technical success and target lesion primary patency at 1 year. Cumulative and survival analysis was performed. Incremental net benefit (INB) and incremental cost effectiveness ratio (ICER) were calculated and the cost-effectiveness acceptability curve (CEAC) was drawn. Results: Baseline variables were equally distributed between the two groups. At 1 year, cumulative target lesion primary patency was significantly higher after DEB application (35% vs. 5% after BA, p < 0.001). Overall, median primary patency was 0.64 years in case of DEB vs. 0.36 years in case of BA (p = 0.0007; unadjusted HR = 0.27 [95%CI: 0.13–0.58]; Cox adjusted HR = 0.23 [95%CI: 0.10–0.50]). ICER was 2198 Euros (€) per primary patency year of dialysis access gained. INB was 1068€ (95%CI: 31–2105€) for a willingness-to-pay (WTP) threshold of 5000€ (corresponding acceptability probability >97

  13. Drug-eluting versus plain balloon angioplasty for the treatment of failing dialysis access: Final results and cost-effectiveness analysis from a prospective randomized controlled trial (NCT01174472)

    International Nuclear Information System (INIS)

    Highlights: •1-Year target lesion primary patency significantly higher after PCB application compared to plain balloon angioplasty in the failing dialysis access. •Significant difference in favor of PCB in cumulative primary patency of AVGs at 1 year. •No significant difference in cumulative primary patency of AVFs treated with PCB at 1 year. •Cost effectiveness analysis performed. •Paclitaxel-coated balloon angioplasty proves to be a cost-effective option for treating dialysis access. -- Abstract: Objective: To report the final results and cost-effectiveness analysis of a prospective randomized controlled trial investigating drug-eluting balloon (DEB) versus plain balloon angioplasty (BA) for the treatment of failing dialysis access ( (NCT01174472)). Methods: 40 patients were randomized to angioplasty with either DEB (n = 20) or BA (n = 20) for treatment of significant venous stenosis causing a failing dialysis access. Both arteriovenous fistulas (AVF) and synthetic arteriovenous grafts (AVG) were included. Angiographic follow up was scheduled every two months. Primary endpoints were technical success and target lesion primary patency at 1 year. Cumulative and survival analysis was performed. Incremental net benefit (INB) and incremental cost effectiveness ratio (ICER) were calculated and the cost-effectiveness acceptability curve (CEAC) was drawn. Results: Baseline variables were equally distributed between the two groups. At 1 year, cumulative target lesion primary patency was significantly higher after DEB application (35% vs. 5% after BA, p < 0.001). Overall, median primary patency was 0.64 years in case of DEB vs. 0.36 years in case of BA (p = 0.0007; unadjusted HR = 0.27 [95%CI: 0.13–0.58]; Cox adjusted HR = 0.23 [95%CI: 0.10–0.50]). ICER was 2198 Euros (€) per primary patency year of dialysis access gained. INB was 1068€ (95%CI: 31–2105€) for a willingness-to-pay (WTP) threshold of 5000€ (corresponding acceptability probability >97

  14. Factors influencing technical success and outcome of percutaneous balloon angioplasty in de novo native hemodialysis arteriovenous fistulas

    Energy Technology Data Exchange (ETDEWEB)

    Heye, Sam, E-mail: sam.heye@uzleuven.be [University Hospitals Leuven, Department of Radiology, Herestraat 49, 3000 Leuven (Belgium); Maleux, Geert, E-mail: geert.maleux@uzleuven.be [University Hospitals Leuven, Department of Radiology, Herestraat 49, 3000 Leuven (Belgium); Vaninbroukx, Johan, E-mail: johan.vaninbroukx@uzleuven.be [University Hospitals Leuven, Department of Radiology, Herestraat 49, 3000 Leuven (Belgium); Claes, Kathleen, E-mail: Kathleen.claes@uzleuven.be [University Hospitals Leuven, Department of Nephrology, Herestraat 49, 3000 Leuven (Belgium); Kuypers, Dirk, E-mail: dirk.kuypers@uzleuven.be [University Hospitals Leuven, Department of Nephrology, Herestraat 49, 3000 Leuven (Belgium); Oyen, Raymond, E-mail: raymond.oyen@uzleuven.be [University Hospitals Leuven, Department of Radiology, Herestraat 49, 3000 Leuven (Belgium)

    2012-09-15

    Objective: To determine predictors of technical success, dysfunction recurrence and patency after percutaneous transluminal angioplasty (PTA) of de novo dysfunctional hemodialysis arteriovenous fistulas (AVFs). Methods: Retrospective analysis of first time PTA of 167 AVF in 162 patients (100 men, 66 ± 13 years). Anatomical (location, length, grade and number of stenoses) and clinical variables (sex, age, prior AVF, diabetes mellitus and AVF age, side and location) were reviewed. Results: 217 stenoses or segmental occlusions were treated. Technical success rate (84.4%) was higher in radiocephalic AVF compared to brachial artery–median vein AVF (p = 0.030) and was negatively correlated with initial stenosis (p = 0.049). Dysfunction recurrence was seen in 52.7% and correlated negatively with technical success (p = 0.013) and AVF age (p = 0.008). Early dysfunction (within 6 months) was negatively correlated with AVF age (p = 0.016) and positively with diabetes (p = 0.003). Higher AVF age resulted in higher primary (p = 0.005) and secondary patency rates (p = 0.037–0.005). Conclusions: Technical success of PTA in hemodialysis AVF is affected by AVF type and initial stenosis and has significant effect on dysfunction recurrence, but not on AVF longevity. Younger AVF has increased risk for (early) recurrent dysfunction and lower patency rates. Patients with diabetes mellitus have higher risk for early dysfunction.

  15. Factors influencing technical success and outcome of percutaneous balloon angioplasty in de novo native hemodialysis arteriovenous fistulas

    International Nuclear Information System (INIS)

    Objective: To determine predictors of technical success, dysfunction recurrence and patency after percutaneous transluminal angioplasty (PTA) of de novo dysfunctional hemodialysis arteriovenous fistulas (AVFs). Methods: Retrospective analysis of first time PTA of 167 AVF in 162 patients (100 men, 66 ± 13 years). Anatomical (location, length, grade and number of stenoses) and clinical variables (sex, age, prior AVF, diabetes mellitus and AVF age, side and location) were reviewed. Results: 217 stenoses or segmental occlusions were treated. Technical success rate (84.4%) was higher in radiocephalic AVF compared to brachial artery–median vein AVF (p = 0.030) and was negatively correlated with initial stenosis (p = 0.049). Dysfunction recurrence was seen in 52.7% and correlated negatively with technical success (p = 0.013) and AVF age (p = 0.008). Early dysfunction (within 6 months) was negatively correlated with AVF age (p = 0.016) and positively with diabetes (p = 0.003). Higher AVF age resulted in higher primary (p = 0.005) and secondary patency rates (p = 0.037–0.005). Conclusions: Technical success of PTA in hemodialysis AVF is affected by AVF type and initial stenosis and has significant effect on dysfunction recurrence, but not on AVF longevity. Younger AVF has increased risk for (early) recurrent dysfunction and lower patency rates. Patients with diabetes mellitus have higher risk for early dysfunction

  16. Percutaneous Balloon Angioplasty for Severe Native Aortic Coarctation in Young Infants Less Than 6 Months: Medium- to Long-term Follow-up

    Science.gov (United States)

    He, Lan; Liu, Fang; Wu, Lin; Qi, Chun-Hua; Zhang, Li-Feng; Huang, Guo-Ying

    2015-01-01

    Background: Although balloon angioplasty (BA) has been performed for more than 20 years, its use as a treatment for native coarctation of the aorta (CoA) during childhood, especially in young infants, remains controversial. This study aimed to assess the effects and potential role of percutaneous transcatheter BA for native CoA as an alternative therapy to surgical repair in young infants. Methods: The 37 patients aged from 6 days to 6 months with severe CoA in congestive heart failure or circulatory shock were admitted for BA. Patient's weight ranged from 2.4 to 6.1 kg. All 37 patients were experiencing cardiac dysfunction, and eight patients were in cardiac shock with severe metabolic acidosis. Eleven patients had an isolated CoA, whereas the others had a CoA associated with other cardiac malformations. Cardiac catheterization and aortic angiography were performed under general anesthesia with intubation. Transfemoral arterial approaches were used for the BA. The size of the balloon ranged from 3 mm × 20 mm to 8 mm × 20 mm, and a coronary artery balloon catheter was preferred over a regular peripheral vascular balloon catheter. Results: The femoral artery was successfully punctured in all but one patient, with that patient undergoing a carotid artery puncture. The systolic peak pressure gradient (PG) across the coarctation was 41.0 ± 16.0 mmHg (range 13–76 mmHg). The mean diameter of the narrowest coarctation site was 1.7 ± 0.6 mm (range 0.5–2.8 mm). All patients had successful dilation; the PG significantly decreased to 13.0 ± 11.0 mmHg (range 0–40 mmHg), and the diameter of coarctation significantly improved to 3.8 ± 0.9 mm (range 2.5–5.3 mm). No intraoperative complications occurred for any patients. However, in one case that underwent a carotid artery puncture, a giant aneurysm formed at the puncture site and required surgical repair. The following observations were made during the follow-up period from 6-month to 7-year: (1) The PG across the

  17. Percutaneous Balloon Angioplasty for Severe Native Aortic Coarctation in Young Infants Less Than 6 Months: Medium-to Long-term Follow-up

    Institute of Scientific and Technical Information of China (English)

    Lan He; Fang Liu; Lin Wu; Chun-Hua Qi; Li-Feng Zhang; Guo-Ying Huang

    2015-01-01

    Background:Although balloon angioplasty (BA) has been performed for more than 20 years,its use as a treatment for native coarctation of the aorta (CoA) during childhood,especially in young infants,remains controversial.This study aimed to assess the effects and potential role of percutaneous transcatheter BA for native CoA as an alternative therapy to surgical repair in young infants.Methods:The 37 patients aged from 6 days to 6 months with severe CoA in congestive heart failure or circulatory shock were admitted for BA.Patient's weight ranged from 2.4 to 6.1 kg.All 37 patients were experiencing cardiac dysfunction,and eight patients were in cardiac shock with severe metabolic acidosis.Eleven patients had an isolated CoA,whereas the others had a CoA associated with other cardiac malformations.Cardiac catheterization and aortic angiography were performed under general anesthesia with intubation.Transfemoral arterial approaches were used for the BA.The size of the balloon ranged from 3 mm × 20 mm to 8 mm × 20 mm,and a coronary artery balloon catheter was preferred over a regular peripheral vascular balloon catheter.Results:The femoral artery was successfully punctured in all but one patient,with that patient undergoing a carotid artery puncture.The systolic peak pressure gradient (PG) across the coarctation was 41.0 ± 16.0 mmHg (range 13-76 mmHg).The mean diameter of the narrowest coarctation site was 1.7 ± 0.6 mm (range 0.5-2.8 mm).All patients had successful dilation;the PG significantly decreased to 13.0 ± 1 1.0 mmHg (range 0-40 mmHg),and the diameter of coarctation significantly improved to 3.8 ± 0.9 mm (range 2.5-5.3 mm).No intraoperative complications occurred for any patients.However,in one case that underwent a carotid artery puncture,a giant aneurysm formed at the puncture site and required surgical repair.The following observations were made during the follow-up period from 6-month to 7-year:(1) The PG across the coarctation measured by

  18. Carbon dioxide-guided angioplasty

    International Nuclear Information System (INIS)

    Revascularization procedures are frequently necessary in patients with severe peripheral vascular disease and renal insufficiency (often coexistent with diabetes mellitus). This paper examines the use of carbon dioxide as the contrast agent in percutaneous revascularization procedures (balloon angioplasty). Over the past 10 months, our protocol has used CO2 as the contrast agent for balloon angioplasty in a select group of patients (n = 12) with peripheral vascular disease and renal insufficiency. Some had coexistent diabetes mellitus. With digital subtraction angiography, CO2 was the only contrast agent used during revascularization. Pressure gradients were obtained in appropriate patients

  19. Percutaneous transluminal angioplasty

    International Nuclear Information System (INIS)

    Percutaneous transluminal angioplasty (PTA) is an accepted procedure for the management of arteriosclerotic occlusive disease and other vascular disorders that compromise blood flow through a vessel to various target structures (e.g., heart, kidney, extremities). The Gruentzig-type balloon dilation catheter has made PTA a versatile, relatively low-risk, relatively low-cost procedure. Its cost effectiveness has been well documented, particularly when consideration is given not only to hospital time but also to loss of productivity. In many institutions, PTA now replaces time-honored surgical procedures. This feature of angioplasty mandates that the angiographer participate actively with surgeons and other clinicians in choosing appropriate patients for PTA. This paper attempts to provide angiographers currently performing or intending to perform PTA with proper guidelines for the selection of patients for the procedure, based on anatomic, physiologic, and clinical grounds. Technical factors involved in performing PTA are included, as are common and uncommon problems and potential complications and how to avoid them. The information presented is drawn from experience that the authors acquired in the performance of over 4,000 angioplasty procedures. Adjuncts to PTA, including fibrinolysis and digital imaging, are given considerations as are the potential for laser-aided transluminal angioplasty

  20. Aorto-iliac angioplasty

    International Nuclear Information System (INIS)

    This paper reports on the results and complications of aortoiliac balloon percutaneous transluminal angioplasty (PTA) and Simpson atherectomy that are compared to determine the role of the latter procedure in the management of aortoiliac disease. In 1984--1988, 92 patients underwent 126 angioplasties of the aortoiliac region. In 1986--1989, 21 patients underwent iliac artery atherectomy. Both groups had similar symptoms, risk factors, and age ranges. The overall technical success rate was 97.6or PTA and 100% for atherectomy. The initial clinical success was 92.8% for PTA and 100% for atherectomy. The 2-year clinical patency rate was 60% for PTA and 64% for artherectomy. Complications requiring surgery occurred in four of 126 (3%) PTA patients and one of 21 (5%) atherectomy patients. Groin hematomas were observed in 16% of PTA patients and 19% of atherectomy patients

  1. Morphologic alterations after transluminal angioplasty

    International Nuclear Information System (INIS)

    Despite the widespread clinical use of percutaneous transluminal angioplasty, the mechanism by which enlargement of the arterial lumen is achieved by this technique has been poorly understood. In the original description of transluminal angioplasty in 1964, the effectiveness of the procedure was attributed to compression of the atheromatous plaque against a relatively unyielding artery wall. This mechanism was subsequently endorsed in relation to angioplasty using the balloon catheter. The concept of plaque compression or displacement or of herniation of the puttylike athermatous intima into the artery wall was generally accepted by the early pioneers in transluminal angioplasty. This mechanism did not, however, correspond to clinical and morphologic observations that plaques were generally rigid and calcific rather than plastic and could not readily be compressed or deformed. Angiographic observations before and after dilatation have not always been helpful in defining the mechanism since angiography reveals only the lumen contour and does not provide sufficient information concerning the thickness of the arterial wall or the size, configuration, or precise boundaries of plaques. Although direct observation of lesions and associated artery walls immediately after balloon dilatation could provide the necessary information, such data are difficult to obtain since arteries and plaques are rarely directly inspected after dilatation in the living patient. Knowledge of the morphologic consequences of balloon dilatation in human arteries has therefore been obtained mainly from experimental studies of postmortem arteries and corresponding angiographic images and from specimens obtained from amputated limbs or after death

  2. Coronary Angioplasty

    Science.gov (United States)

    ... page from the NHLBI on Twitter. What Is Percutaneous Coronary Intervention? Español Percutaneous (per-ku-TA-ne-us) coronary intervention (PCI), commonly known as coronary angioplasty (AN-jee- ...

  3. Novel paclitaxel-coated angioplasty balloon catheter based on cetylpyridinium salicylate: Preparation, characterization and simulated use in an in vitro vessel model

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, Svea, E-mail: svea.petersen@uni-rostock.de [Institute for Biomedical Engineering, University of Rostock, Friedrich-Barnewitz-Straße 4, 18119 Rostock (Germany); Kaule, Sebastian [Institute for Biomedical Engineering, University of Rostock, Friedrich-Barnewitz-Straße 4, 18119 Rostock (Germany); Stein, Florian [Institute for Chemistry, Analytical and Technical Chemistry University of Rostock, Albert-Einstein-Straße 3a, 18059 Rostock (Germany); Minrath, Ingo; Schmitz, Klaus-Peter [Institute for Biomedical Engineering, University of Rostock, Friedrich-Barnewitz-Straße 4, 18119 Rostock (Germany); Kragl, Udo [Institute for Chemistry, Analytical and Technical Chemistry University of Rostock, Albert-Einstein-Straße 3a, 18059 Rostock (Germany); Sternberg, Katrin [Institute for Biomedical Engineering, University of Rostock, Friedrich-Barnewitz-Straße 4, 18119 Rostock (Germany)

    2013-10-15

    Drug-coated balloons (DCB), which have emerged as therapeutic alternative to drug-eluting stents in percutaneous cardiovascular intervention, are well described with regard to clinical efficiency and safety within a number of clinical studies. In vitro studies elucidating the correlation of coating method and composition with DCB performance are however rare but considered important for the understanding of DCB requirements and the improvement of established DCB. In this context, we evaluated the applicability of a pipetting, dip-coating, and spray-coating process for the establishment of DCB based on paclitaxel (PTX) and the ionic liquid cetylpyridinium salicylate (Cetpyrsal) as novel innovative additive in three different compositions. Among tested methods and compositions, the pipetting process with 50 wt.% PTX resulted in most promising coatings as drug load was less controllable by the other processes and higher PTX contents led to considerable drug crystallization, as visualized by electron microscopy, accelerating PTX loss during short-term elution. Applying these conditions, homogeneous coatings could be applied on balloon catheter, whose simulated use in an in vitro vessel model revealed percental drug losses of 36 and 28% during transit and percental drug transfers of 12 and 40% under expansion for coatings applied in expanded and folded balloon condition, respectively. In comparison to literature values, these results support the high potential of Cetpyrsal as novel DCB matrix regarding low drug loss and efficient drug transfer. - Highlights: • We provide detailed in vitro data for definition of DCB coating requirements. • An in vitro vessel model for evaluating drug delivery from DCB is presented. • Innovative ionic liquid-based coatings for DCB are developed. • The coating shows low drug loss and efficient drug transfer.

  4. Novel paclitaxel-coated angioplasty balloon catheter based on cetylpyridinium salicylate: Preparation, characterization and simulated use in an in vitro vessel model

    International Nuclear Information System (INIS)

    Drug-coated balloons (DCB), which have emerged as therapeutic alternative to drug-eluting stents in percutaneous cardiovascular intervention, are well described with regard to clinical efficiency and safety within a number of clinical studies. In vitro studies elucidating the correlation of coating method and composition with DCB performance are however rare but considered important for the understanding of DCB requirements and the improvement of established DCB. In this context, we evaluated the applicability of a pipetting, dip-coating, and spray-coating process for the establishment of DCB based on paclitaxel (PTX) and the ionic liquid cetylpyridinium salicylate (Cetpyrsal) as novel innovative additive in three different compositions. Among tested methods and compositions, the pipetting process with 50 wt.% PTX resulted in most promising coatings as drug load was less controllable by the other processes and higher PTX contents led to considerable drug crystallization, as visualized by electron microscopy, accelerating PTX loss during short-term elution. Applying these conditions, homogeneous coatings could be applied on balloon catheter, whose simulated use in an in vitro vessel model revealed percental drug losses of 36 and 28% during transit and percental drug transfers of 12 and 40% under expansion for coatings applied in expanded and folded balloon condition, respectively. In comparison to literature values, these results support the high potential of Cetpyrsal as novel DCB matrix regarding low drug loss and efficient drug transfer. - Highlights: • We provide detailed in vitro data for definition of DCB coating requirements. • An in vitro vessel model for evaluating drug delivery from DCB is presented. • Innovative ionic liquid-based coatings for DCB are developed. • The coating shows low drug loss and efficient drug transfer

  5. Angioplasty and stent placement - heart

    Science.gov (United States)

    ... angioplasty; Coronary artery angioplasty; Percutaneous transluminal coronary angioplasty; Heart artery dilatation ... to carefully guide the catheter up into your heart and arteries. Dye will be injected into your ...

  6. Intravascular ultrasound imaging following balloon angioplasty.

    OpenAIRE

    Tobis, JM; Mahon, DJ; Moriuchi, M; Honye, J; McRae, M

    1991-01-01

    Despite its long history and reliability, contrast angiography has several inherent limitations. Because it is a two-dimensional projection image of the lumen contour, the wall thickness cannot be measured and the plaque itself is not visualized. This results in an underestimation of the amount of atherosclerotic disease by angiography. An assessment of atherosclerosis could be improved by an imaging modality: (1) that has an inherent larger magnification than angiography and (2) that directl...

  7. Infrapopliteal angioplasty in the treatment of ischaemic diabetic lower limbs

    International Nuclear Information System (INIS)

    Objective: To evaluate the clinical effect of infrapopliteal arterial balloon angioplasty in the treatment of ischaemic diabetic lower limbs. Methods: 53 cases of ischaemic diabetic lower limb containing 64 ischemic limbs were treated with infrapopliteal angioplasty by Amphirion Deep Balloon. Observation of clinical remission including the ulcers was carried out before and after the procedure. Results: 119 ateries of the 53 cases were chosen for PTA and 101 PTA in 50 cases were accomplished, with technical success rate of 84.9%. All the 50 patients got clinical remission including the shrinkage of ulcers and none amputation. Conclusin: Infrapopliteal arterial angioplasty is effective, minimal invasive and safe for the ischaemic diabetic lower limbs. (authors)

  8. Percutaneous endoluminal angioplasty of post endarterectomy carotid stenoses

    International Nuclear Information System (INIS)

    Percutaneous transluminal angioplasty of the carotid artery was performed in four patients with recurrent stenosis following endarterectomy. Balloon catheter dilatation was successful in 3 of the 4 lesions. Post dilatation angiography demonstrated an increase in luminal diameter: there were no neurological complications with the procedure. PTA appears to be an effective method of treating recurrent stenosis following carotid endarterectomy. (orig.)

  9. 微创Sky手术与球囊成形术治疗脊柱骨质疏松压缩性骨折的效果比较%Comparative study on the effect of Sky minimally invasive surgery and balloon angioplasty in the treatment of spinal osteoporotic compression fractures

    Institute of Scientific and Technical Information of China (English)

    吕海文

    2016-01-01

    Objective To compare the effect of Sky minimally invasive surgery and balloon angioplasty in the treatment of spinal osteoporotic compression fractures.Methods 61 cases of spinal osteoporotic compression fractures in our hospital from April 2012 to August 2013 were selected and divided into two groups according to the random number table,of whom 30 cases were treated with Sky bone expander surgery (Sky group),31 cases were treated with percutaneous balloon vertebroplasty (balloon group).Compared the effect of two groups combined with postoperative follow-up.Results There was no statistically significant difference in treatment efficiency between Sky group and balloon group (93.3% vs.93.5%,P>0.05).There were no statistically significant differences in operation time,intraoperative blood loss and self-rating pain score between Sky group and balloon group [(41.4±5.3)min vs.(39.5±5.5)min,(17.6±4.1)ml vs.(19.0±4.3)ml,(2.9± 1.1) vs.(3.1 ± 1.0);P>0.05].There were no postoperative complications in both two groups.Conclusion Sky minimally invasive surgery and balloon angioplasty are both effective methods for the treatment of spinal osteoporotic compression fractures,which can significantly improve spinal function and relief spinal pain.%目的 比较微创Sky手术与球囊成形术治疗脊柱骨质疏松压缩性骨折的效果.方法 选取我院2012年4月至2013年8月61例脊柱骨质疏松压缩性骨折患者,根据随机数表分为两组,其中30例采用Sky骨扩张器手术治疗(记为Sky组),31例采用经皮球囊扩张椎体成形术治疗(记为球囊组).结合术后随访观察两组治疗效果.结果 Sky组治疗有效率相较球囊组差异无统计学意义(93.3%vs.93.5%,P>0.05);Sky组手术时长[(41.4±5.3) min]、术中出血量[(17.6±4.1)ml]、患者自我疼痛评分(2.9±1.1)与球囊组[(39.5±5.5) min、(19.0±4.3) ml、(3.1±1.0)]相比,差异无统计学意义(P>0.05);两组术后均未出现并发症.结论 微

  10. Changes of nitric oxide and endothelin serum level after carotid balloon denudation or stent assisted angioplasty: an experimental and clinical observation%颈动脉球囊扩张与支架置入术后血清一氧化氮和内皮素变化的实验与临床观察

    Institute of Scientific and Technical Information of China (English)

    刘加春; 王大明; 钱江南; 李雅国; 王利军; 姜学丽; 翟乐乐; 陆军; 祁鹏

    2009-01-01

    Objective To observe the changes of nitric oxide (NO) and endothelin (ET) serum level in the Guangxi BA-MA minipigs whose carotid arteries were injured by balloon denudation and in the patients with catotid stent assisted angioplasty. Methods Twelve Guangxi BA-MA minipigs were choosen. High fat/cholesterol feeding and endovascular balloon denudation were used to create a carotid artery atherosclerotic stenosis animal model. Blood samples were collected from peripheral veins before starting the procedure, and again, at 2 and 3 weeks after the procedure, respectively. Serum NO and ET concentrations of blood samples were tested. Nineteen patients with carotid artery stenosis who underwent stent assisted angioplasty were randomly selected, and their serum NO and ET were tested using the same methods as above. Results In the animal group, there was a significant decrease of mean NO concentration at 2 weeks after carotid injury (t-test, P<0.05 ), however, no significant change of ET was observed. A very significant increase of ET was observed at 3 weeks after the procedure (t-test, P <0.01 ). In the patient group, there were no significant differences among serum NO or ET concentration of peripheral vein blood before, immediately after, and 6 h after the endovascular treatment. Conclusions In this study, a decrease of NO concentration and an increase of ET concentration of peripheral vein blood are found in BA-MA minipigs after carotid arteries are injured by balloon denudation, which might be a cue for the formation of atherosclerosis. However, no significant changes are observed in this group of patients who underwet carotid angioplasty treatment. Therefore, further studies are needed.%目的:观察小型猪颈动脉球囊扩张前后和颈动脉狭窄患者狭窄扩张、支架置入术前后血清一氧化氮(NO)和内皮素(ET)的变化.方法:选取12头广西巴马小型猪,分别于颈动脉球囊损伤前、损伤后2周和3周检测静脉血血清中NO

  11. Coronary Angioplasty Stent Placement

    Medline Plus

    Full Text Available Coronary Angioplasty Stent Placement Shawnee Mission Heart & Vascular Center, Shawnee Mission, Kansas February 19, 2009 Welcome to this OR-Live westbound cast presentation, live from Shawnee Mission Medical Center ...

  12. Intracoronary irradiation with rhenium 188 to reduce restenosis following a coronary angioplasty. Preliminary results

    International Nuclear Information System (INIS)

    This paper shows the preliminary results from our contribution to a coordinated project with the International Atomic Energy Agency, which corroborates that the intracoronary irradiation allows to reduce the restenosis following a percutaneous transluminal coronary angioplasty (PTCA) in patients with ischemic cardiopathy as a result of neointima hyperplasia reduction. In the treatment, both beta and gamma emitters can be used, but with the latter (specifically with rhenium 188), its is possible to use an angioplasty balloon catheter for therapy purposes

  13. Protective effect of collateral vessels during coronary angioplasty.

    OpenAIRE

    Norell, M. S.; Lyons, J. P.; Gardener, J E; Layton, C A; Balcon, R

    1989-01-01

    To assess the potential protective role of collateral vessels 27 patients undergoing angioplasty of the left anterior descending coronary artery were studied by intravenous digital subtraction left ventriculography. Fifteen patients had no collateral vessels (group 1) and 12 had some degree of collateral supply (group 2). During balloon inflation ST segment elevation in group 1 (4.9 mm) was significantly greater than that in group 2 (0.9 mm). Similarly the reduction in left ventricular ejecti...

  14. [Percutaneous coronary Excimer laser angioplasty in patients with coronary heart disease].

    Science.gov (United States)

    Karsch, K R; Haase, K K; Mauser, M; Ickrath, O; Voelker, W; Baumbach, A; Seipel, L

    1990-07-01

    To verify the efficacy and safety of percutaneous coronary excimer laser angioplasty in patients with coronary artery disease a prospective study was conducted in 60 patients. The application of laser light was possible in 55 of the 60 patients. A novel 1.4-mm diameter catheter with 20 quartz fibers of 100-microns diameter, each arranged concentrically around a central lumen suitable for an 0.014-inch flexible guide wire was used. The light source was a commercial excimer laser emitting energy at a wavelength of 308 nm, with a pulse duration of 60 ns. The laser was operated at 20 Hz; mean energy transmission was 30 +/- 5 mJ/mm2. In 23 of the 55 patients treated with excimer laser energy the qualitative angiographic results were sufficient. In 32 patients additional balloon angioplasty was necessary, either because of an insufficient result or due to vessel closure after laser ablation. In 47 of the 55 patients control angiography was performed within the 6-month follow-up period. Rate of restenosis was higher in patients treated with laser ablation and subsequent balloon angioplasty (16 of 28) than in patients treated with laser ablation alone (6 of 19). Results of the 6-month observation period suggest that 1) coronary excimer laser angioplasty in combination with subsequent balloon angioplasty results in a considerable increase of the restenosis rate; 2) the exclusive use of laser ablation also results in a restenosis rate comparable to balloon angioplasty alone; and 3) the impact of this new method using improved application systems and higher energy transmission has to be determined in further studies. PMID:2399764

  15. Coronary Angioplasty Stent Placement

    Medline Plus

    Full Text Available ... and suction out the clot, and that helps open up the vessel. I think we’ve been ... The balloons and wires that we use to open the blockages up, they have become much more ...

  16. Coronary Angioplasty Stent Placement

    Medline Plus

    Full Text Available ... change. The catheters that we use to gain access into the vessels are smaller. They’re more user- friendly. The balloons and wires that we use to open the blockages up, they have become much more ...

  17. Coronary Angioplasty Stent Placement

    Medline Plus

    Full Text Available ... paves the path so we can pass the metal stent. And then we take a stent and ... open up that balloon, and it expands that metal stent, which is generally stainless steel in compound, ...

  18. The mechanism of angioplasty

    International Nuclear Information System (INIS)

    A model was developed which allows the dilatation of iliac cadaver arteries under normal blood pressure conditions (mean pressure 100 mmHg). Segments of the iliac artery were put under pressure and dilated with balloons under similar conditions as in clinical practice. Purposely oversized balloons were used because most of the arteries did not contain severely stenotic plaques and consequently the commercially available balloons had no effect because of their comparatively small diameter. In spite of the use of oversized balloons, the cadaver arteries could not be significantly dilated. Rupture of the intima and media was almost invariably present. Leakage of distending fluid through the adventitia occurred commonly. The 'therapeutic range' between minimal dilation and partial or total rupture in postmortem studies is small. (orig.)

  19. Use of Reactor-Produced Radioisotopes for Prevention Restenosis After Angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, F.F.; Pipes, D.W.

    1999-12-21

    Coronary heart disease leads to myocardial infarction and is a major cause of death in the US. Myocardial infarctions result from atherosclerotic plaque deposits in the coronary arteries, reducing blood flow through these arteries which supply oxygen and nutrients to the heart muscle. The two major approaches for restoring adequate blood flow are coronary bypass graft surgery and coronary angioplasty. Angioplasty is a routinely used clinical procedure, where a deflated balloon attached to the end of a long catheter is inserted into an artery in the leg and then advanced through the aorta into the blocked regions of the coronary arteries. After positioning in the occluded region of the artery, the balloon is inflated with a pressurized saline solution which opens the artery restoring blood flow by pressing the atherosclerotic plaque into the vessel wall. Angioplasty is a widely performed procedure with the coronary arteries and is a much less expensive alternative to coronary bypass surgery. The best patients for angioplasty are those with single occlusions and this method is preferred over bypass grafting because of the significantly reduced expense. The reformation of plaque deposits in arteries (restenosis) following angioplasty, however, is a major clinical problem encountered in as high as 40 percent of patients. Because reduction of health care costs is a major national priority, development of effective new preventative methods for restenoses is an important national priority.

  20. Use of Reactor-Produced Radioisotopes for Prevention Restenosis After Angioplasty

    International Nuclear Information System (INIS)

    Coronary heart disease leads to myocardial infarction and is a major cause of death in the US. Myocardial infarctions result from atherosclerotic plaque deposits in the coronary arteries, reducing blood flow through these arteries which supply oxygen and nutrients to the heart muscle. The two major approaches for restoring adequate blood flow are coronary bypass graft surgery and coronary angioplasty. Angioplasty is a routinely used clinical procedure, where a deflated balloon attached to the end of a long catheter is inserted into an artery in the leg and then advanced through the aorta into the blocked regions of the coronary arteries. After positioning in the occluded region of the artery, the balloon is inflated with a pressurized saline solution which opens the artery restoring blood flow by pressing the atherosclerotic plaque into the vessel wall. Angioplasty is a widely performed procedure with the coronary arteries and is a much less expensive alternative to coronary bypass surgery. The best patients for angioplasty are those with single occlusions and this method is preferred over bypass grafting because of the significantly reduced expense. The reformation of plaque deposits in arteries (restenosis) following angioplasty, however, is a major clinical problem encountered in as high as 40 percent of patients. Because reduction of health care costs is a major national priority, development of effective new preventative methods for restenoses is an important national priority

  1. Study on the dynamic change of endothelin in the development of stenosis of aorta after balloon injury in rabbits

    International Nuclear Information System (INIS)

    Objective: To study the dynamic change of endothelin (ET) in the blood with pathological and immunohistochemical changes of ET(ET-immunoreaction, ET-IR) in the development of stenosis of rabbit aorta after transluminal angioplasty. Methods: According to the different periods of being killed after micro-balloon angioplasty, 30 rabbits were divided randomly into 6 groups including 6-hour group, 1-day group, 3-day group, 7-day group, 15-day group and 22-day group. 3 out of 5 rabbits in each group were created as models of aortic endothelium injury by micro-balloon angioplasty, the rest 2 rabbits were taken as control. ET levels in the plasma were measured by ELISA before, as well as after micro-balloon angioplasty. Pathomorphological examination of the local traumatic aorta was carried out to observe the intimal thickness and the extent of lumen stenosis, and ET-IR was assessed by immunohistochemical technique performed on aortic wall after micro-balloon angioplasty. Results: (1) The major change of vascular stenosis was proliferation of vascular smooth muscle cell (VSMC) and endothelium. (2) ET levels in the plasma and ET-IR on the local aortic wall were significantly increased after micro-balloon angioplasty. Conclusions: The experimental results show that the major pathologic change of vascular stenosis is the obvionus proliferation of VSMC and endothelium. Further more, ET is a key factor in the development of vascular stenosis. (authors)

  2. Segmentally enclosed thrombolysis in percutaneous transluminal angioplasty for femoropopliteal occlusions

    DEFF Research Database (Denmark)

    Jørgensen, B; Tønnesen, K H; Nielsen, J D; Holstein, P; Bülow, J; Jørgensen, M; Andersen, E

    1991-01-01

    Segmentally enclosed thrombolysis (SET) was performed immediately following 34 percutaneous transluminal angioplasties (PTAs) for femoropopliteal occlusions. The dilated segment was sealed off with a double balloon catheter, and recombinant tissue plasminogen activator (rt-PA) 1 mg/ml and heparin...... clinically relevant changes in plasma fibrinogen occurred. Two puncture site hemorrhages did not coincide with the coagulopathy induced by SET. One-year patency was 80%. Early rethrombosis occurred in 9% versus 41% in our previous series on standard PTA for femoropopliteal occlusions (p less than 0...

  3. Assessment of left ventricular performance during percutaneous transluminal coronary angioplasty: a study by intravenous digital subtraction ventriculography.

    OpenAIRE

    Norell, M. S.; Lyons, J. P.; Gershlick, A H; Gardener, J E; Rothman, M. T.; Layton, C A; Balcon, R

    1988-01-01

    Left ventricular performance during percutaneous transluminal coronary angioplasty was assessed in 52 patients by intravenous digital subtraction ventriculography. After injection of contrast into the right atrium ventriculograms were obtained before and during balloon inflation. In 37 patients they were also obtained after the procedure. A 12 lead electrocardiogram was monitored throughout. During balloon inflation the left ventricular ejection fraction fell (from 73% to 57%) in all but one ...

  4. Percutaneous peripheral laser angioplasty with a pulsed Nd:YAG laser and sapphire tips

    Science.gov (United States)

    Kvasnicka, Jan; Stanek, Frantisek; Boudik, Frantisek; Kubecek, Vaclav; Krivanek, Jiri; Keclik, Richard; Prochazkova, Helena; Hamal, Karel

    1990-07-01

    Percutaneous transluminal laser angioplasty with a pulsed Nd:YAG laser (1,064 nm wavelength, 100 jig pulse duration, up to 0.4 J per pulse, 10 Hz repetition rate) coupled to optical fibers with sapphire tips of 1.8, 2.2 and 2.9 mm diameter was performed in 17 chronic occlusions of iliac, femoral, popliteal and fibular arteries in 15 patients. Clinically the procedure was successful in 14 cases. The probe formed a primary channel of at least 2.0 mm width which was further dilated by conventional balloon catheter. Ankle/brachial systolic pressure index (ABPI) increased from 0.46 0.13 to 0.84 0.21 after the procedure. Two failures were due to an extensive dissection which occurred after balloon angioplasty and resulted in an early reocclusion. In the remaining case a balloon catheter could not be introduced through the 30 cm long primary channel which reoccluded shortly after the recanalization. The initial patency rate was 82 % and in 5 patients followed for more then 6 months the ABPI showed only a minor decrease. These first results are encouraging and it is likely that this method could become an important alternative to conventional balloon angioplasty.

  5. Percutaneous transluminal laser angioplasty

    International Nuclear Information System (INIS)

    In this paper the authors report on a new technique-percutaneous transluminal laser angioplasty (PLR) which was performed on 9 patients with iliac and/or femoro-popliteal artery occlusion. All patients were males (mean age: 64.5 years) and had arterial occlusion (mean lenght: cm 12.5). PLR was performed with an argon laser (max power: 16 Watts). In 8 out of 9 patients (88.8%) a complete recanalization was obtained of the occluded arterial tract, without complications. In one case only (12.2%) there was an arterial wall perforation with unsatisfactory results. In our opinion, PLR has proven a simple methodology, which can be performed on any patient due to the very low incidence of severe complications and distal embolism. Moreover PLR has quite low costs, and does not prevent eventual surgical/percutaneous interventions

  6. Percutaneous transluminal angioplasty (PTA) of the infrarenal abdominal aorta

    International Nuclear Information System (INIS)

    The results of percutaneous transluminal angioplasty (PTA) (n=13) of the lower abdominal aorta are reported in 12 patients. The mean patient age was relatively low (46 years). In 7 cases there were isolated aortic obstructions (6 stenoses, 1 occlusion). In the remaining 6 aortic stenoses, there were also major atherosclerotic lesions distally. The mean diameter of the aortic section in which PTA was performed, measured 8.2 mm. The total diameter of the PTA balloon(s) averaged 19.1 mm. The arterial gradient dropped significantly from 41.4 mm Hg (mean) to 2 mm Hg after PTA. The arm-ankle index increases significantly from 0.64 to 0.97. The follow-up included 9 patients; 1 showed restenosis 38 month after PTA. There were no clinically relevant complications. The data published on abdominal PTA in atherosclerotic lesions are summarized. (orig.)

  7. Renal artery stent angioplasty for renovascular hypertension

    International Nuclear Information System (INIS)

    Objective: To evaluate the therapeutic results of expandable stent for treatment of atherosclerotic renovascular obstructive disease. Methods: 15 patients (10 men and 5 women, 41-75 years old; mean age, 52 years) with renal arterial hypertension underwent renal stent angioplasty including renal arterial stenosis 89%(n=13) and fully obstruction without function in 2, of which 2 patients had bilateral involvement. The stenotic range of all arterial segments showed 60% to 90% width of the normal arterial diameter. 16 stents were implanted under the guidance of fluoroscopy. The most of stents implanted were Palmaz (n=12, 75%) with regular clinical and angiographic follow up. Results: Technical success (residual stenosis <30%) was achieved in all patients without serious complication. During the follow-up (6-15 months; mean, 8 ± 4 months), hypertension was improved in 9 patients and cured in 4 patients with a total benefit of 86% and no efficacy in 2(13%). The average systolic blood pressure decreased from 27.12 ± 3.09 kPa to 18.62 ± 3.12 kPa and the average diastolic blood pressure decreased from 17.73 ± 1.92 kPa to 11.12 ± 2.43 kPa after stent treatment (P<0.05). Serum creatinine remained stable in 60% (n=9) patients with improvement in 33% (n=5) and worsened in 6% (n=1) patients. Follow-up angiography was performed in all patients with 1 case of a restenosis. 6 months after expanding through stent by using balloon, the two follow up angiographies showed a stable restenosis about 20%. Conclusions: Percutaneous transluminal stent placement is highly beneficial for patients who had renal arterial obstructive disease. The success of stent angioplasty of complete obstructive renal arteries reveals wide prospects for interventional method. (authors)

  8. Angiotensin Ⅱ type 2 receptor gene mediated by the tetracycline-regulatable system inhibits neointimal hyperplasia in rat carotid arteries after balloon angioplasty%血管紧张素Ⅱ2型受体在体可调控表达对大鼠颈动脉新生内膜增生的影响

    Institute of Scientific and Technical Information of China (English)

    苗莉; 罗先润; 景涛; 张辉; 刘安丰; 娄云霄; 何国祥

    2011-01-01

    Objective Transducing the angiotensin Ⅱ type 2 receptor (AT2R) gene into rat balloon injury carotid arteries can attenuate neointimal hyperplasia, but how to regulate the expression of the AT2.R gene according to our need is very important in utilizing transgenie technology. The purpose of the current study is to investigate the effects of the AT2R gene medicated by the tetracy-cline regulatable system on neointimal hyperplasia in rat carotid arteries after balloon angioplasty. Methods After establishment of the rat model of carotid balloon injury restenosis, we locally perfused into the rat carotid arteries PBS (the control group), mesenchy-mal stem cells (the MSC group) or MSC/AT2R (the MSC/AT2R group) with AT2R medicated by the tetracycline regulatable system, the latter again subdivided into a doxycycline administration (Dox) and non-doxycycline Dox administration (non-Dox) group. At 14 and 28 days after the operation, we evaluated the expression of AT2R by immunohistochemistry and RT-PCR and measured the neointi-ma/media (I/M) area ratio was by morphometric analysis. Results In the MSC/AT2R + Dox group, the expressions of AT2R mRNA and protein in the neointima were significantly up-regulated from day 14 to 28 after injury (P <0.01), and the I/M ratio significantly reduced (P<0.01). The transplanted MSC showed no obvious effect on the neointimal hyperplasia. Conclusion The expression of the AT2R gene can be regulated efficiently in vivo by local delivery of MSC with dual-stable expression of the AT2R gene, and thus inhibit neointimal hyperplasia.%目的 血管紧张素Ⅱ2型受体(angiotensinⅡtype 2 receptor,AT2R)基因转染可减轻血管损伤后新生内膜的过度增生,但如何主动调控转入体内基因的表达有着重要的临床意义.文中以四环素可调控系统下的AT2R基因转染的骨髓间充质干细胞(mesenchymal stem cell,MSC)为载体,探讨AT2R在体可调控表达及对大鼠颈动脉新生内膜的影响.方法 大鼠

  9. Prediction of outcome after femoropopliteal balloon angioplasty by intravascular ultrasound

    DEFF Research Database (Denmark)

    Vogt, K C; Just, S; Rasmussen, John Bøje Grønvall;

    1997-01-01

    arteries remained patent. Two occlusions and two stenoses developed during the first 3 months after the intervention and one occlusion occurred after 1 year. The following IVUS parameters were related to a favourable patency: presence of calcification; dissection or plaque rupture and residual stenosis of...... less than 70%. The arteriographically determined diameter reduction did not show predictive value. CONCLUSION: This study shows that in contrast to arteriography, IVUS revealed parameters predictive for patency following PTA....

  10. Angioplasty - Multiple Languages: MedlinePlus

    Science.gov (United States)

    ... Supplements Videos & Tools You Are Here: Home → Multiple Languages → All Health Topics → Angioplasty URL of this page: https://medlineplus.gov/languages/angioplasty.html Other topics A-Z A B ...

  11. Successful Venous Angioplasty of Superior Vena Cava Syndrome after Heart Transplantation

    Directory of Open Access Journals (Sweden)

    Thomas Strecker

    2014-01-01

    Full Text Available Introduction. For patients with terminal heart failure, heart transplantation (HTX has become an established therapy. Before transplantation there are many repeated measurements with a pulmonary artery catheter (PAC via the superior vena cava (SVC necessary. After transplantation, endomyocardial biopsy (EMB is recommended for routine surveillance of heart transplant rejection again through the SVC. Case Presentation. In this report, we present a HTX patient who developed a SVC syndrome as a possible complication of all these procedures via the SVC. This 35-year-old Caucasian male could be successfully treated by balloon dilatation/angioplasty. Conclusion. The SVC syndrome can lead to pressure increase in the venous system such as edema in the head and the upper part of the body and further serious complications like cerebral bleeding and ischemia, or respiratory problems. Balloon angioplasty and stent implantation are valid methods to treat stenoses of the SVC successfully.

  12. Treatment of blue digit syndrome with percutaneous transluminal angioplasty-angiographic features

    International Nuclear Information System (INIS)

    Since 1978, the authors have treated nine patients with blue toe syndrome and one patient with blue finger syndrome using percutaneous transluminal angioplasty rather than surgery. None of the patients had distal embolization as a consequence of the balloon dilation. Nine patients have had no evidence of recurrent embolization on follow-up. One patient had a questionable single episode of recurrent embolization. The angiographic, hemodynamic, and clinical features of these ten patients which have been associated with a successful result are outlined

  13. Stent angioplasty of iliac artery stenoses under MR-control: initial clinical results

    International Nuclear Information System (INIS)

    Purpose: To investigate the feasibility of MR-guided stent angioplasty of iliac artery stenozls under passive visualization. Material and methods: Three patients with short, concentric stenoses of the iliac arteries were enrolled. The vascular interventions were performed on a 1.5 T MR scanner (Magnetom Symphony, Siemens, Erlangen, Germany). Stents, guidewires, and balloon catheters were visualized on the basis of susceptibility artifacts. Contrast-enhanced MR angiography (ceMRA) was used to localized the stenosis prior to stent deployment. Nitinol stents were placed under MR-guidance using a fast 2D gradient echo technique. Balloon dilatiation was performed with an angioplasty catheter inflated with diluted gadolinium-DTPA. Postinterventional results were evaluated by ceMRA, DSA, and Doppler indices. Results: Position of the stent, stent deployment, and balloon dilatation were depicted by MR. All stents were correctly placed within the stenosis. Stent positions as monitored by MRI were identical to those seen on DSA images. All patients were treated successfully by the MR-guided intervention. Conclusion: An MR-guided stent angioplasty of simple iliac artery stenoses is feasible under passive visualization. (orig.)

  14. Drug-eluting balloon catheters for lower limb peripheral arterial disease: the evidence to date

    Directory of Open Access Journals (Sweden)

    Barkat M

    2016-05-01

    Full Text Available Mohamed Barkat,1 Francesco Torella,1 George A Antoniou2 1Liverpool Vascular and Endovascular Service, Royal Liverpool University Hospital, Liverpool, 2Department of Vascular and Endovascular Surgery, The Royal Oldham Hospital, Pennine Acute Hospitals NHS Trust, Manchester, UK Abstract: A significant proportion of patients with severe lower limb peripheral arterial disease require revascularization. Over the past decade, an endovascular-first approach even for complex disease has gained widespread use among vascular specialists. An important limitation of percutaneous transluminal balloon angioplasty or stenting remains the occurrence of restenosis. Drug-coated balloons have emerged as an exciting technology developed to overcome the limitations of standard balloon angioplasty and stenting. Drug-eluting devices inhibit neointimal growth of vascular smooth muscle cells with the potential of preventing restenosis. This review provides a synopsis of the up-to-date evidence on the role of drug-coated balloons in the treatment of lower limb peripheral arterial disease. Bibliographic searches were conducted using MEDLINE, EMBASE, and the Cochrane Library electronic database. Eleven randomized clinical trials, two systematic reviews, and a published registry providing the best available evidence were identified. Current evidence suggests that angioplasty with drug-coated balloon is reliable, safe, and efficient in increasing patency rates and reducing target lesion revascularization and restenosis. However, it remains unknown whether these improved results can translate into beneficial clinical outcomes, as current randomized clinical trials have failed to demonstrate a significant benefit in limb salvage and mortality. Further randomized trials focusing on clinical and functional outcomes of drug-eluting balloons and on cost versus clinical benefit are required. Keywords: drug-eluting balloon, drug-coated balloon, angioplasty, peripheral arterial

  15. Peripheral Applications of Drug-Coated Balloons: Past, Present and Future

    Energy Technology Data Exchange (ETDEWEB)

    Krokidis, Miltiadis, E-mail: mkrokidis@hotmail.com; Spiliopoulos, Stavros, E-mail: stavspiliop@upatras.gr; Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Sabharwal, Tarun, E-mail: tarun_sabharwal@yahoo.co.uk [Guy' s and St. Thomas' Hospitals, NHS Foundation Trust, Department of Radiology (United Kingdom)

    2013-04-15

    Drug-coated balloon (DCB) technologies represent the latest and hottest development in the field of endovascular treatment of peripheral arterial disease. Initial experience with paclitaxel-coated balloon use in the femoral artery has demonstrated lower mid-term restenosis and superior mid-term clinical outcomes in terms of improved wound healing and reduced repeat angioplasty rates compared with standard balloon angioplasty. Many companies are presently developing and/or improving DCB catheters and therefore ongoing, technical improvements of the already existing platforms, new drugs, and innovative carriers are expected. The ongoing basic research studies and various multicenter randomized, controlled trials that are currently in progress will offer valuable scientific insights regarding the long-term effectiveness and other crucial issues, such as efficacy in various vascular beds, optimal balloon dosage, and post angioplasty antiplatelet therapy. Future applications of these devices also could include in-stent restenosis, anastomotic stenosis of surgical bypass, and benign stenoses of the central venous system. The authors envision that DCB angioplasty will evolve to a major paradigm shift in the endovascular treatment of occlusive vascular diseases.

  16. Randomised comparison of coronary stenting with and without balloon predilatation in selected patients

    OpenAIRE

    Le Breton, H; Boschat, J; Commeau, P; Brunel, P.; Gilard, M; Breut, C; Bar, O.; Geslin, P; Tirouvanziam, A; Maillard, L.; Moquet, B; Barragan, P.; Dupouy, P.; Grollier, G; Berland, J.

    2001-01-01

    BACKGROUND—The SWIBAP (stent without balloon predilatation) prospective randomised trial was designed to compare direct coronary stenting with stenting preceded by lesion predilatation with an angioplasty balloon.
OBJECTIVE—To determine the feasibility and safety of direct stenting in non-complex coronary lesions in a prospective study.
PATIENTS AND DESIGN—All patients  3.0 mm, who granted their informed consent, were randomised into the trial. In group I, the stent was placed without balloon...

  17. Drug-Coated Balloons for Infrainguinal Peripheral Artery Disease.

    Science.gov (United States)

    Sethi, Sanjum S; Lee, Michael S

    2016-07-01

    Revascularization of infrainguinal peripheral artery disease has traditionally been accomplished via percutaneous transluminal angioplasty. However, long-term results have been hampered by high rates of restenosis. Along with the advent of stents, paclitaxel-coated balloons are an emerging therapeutic option for the invasive management of infrainguinal peripheral artery disease. Paclitaxel has been successful in inhibiting neointimal hyperplasia, the main mechanism for in-stent restenosis. Technological advances have facilitated the development of paclitaxel-coated balloons, which show promise in early trials for femoropopliteal stenosis relative to uncoated balloons. For infrapopliteal stenoses, the data remain scant and conflicted. Therefore, large-scale randomized clinical trials with long-term follow-up evaluating safety and effectiveness between various strategies need to be performed to determine the optimal invasive management strategy for infrainguinal peripheral artery disease. PMID:27342205

  18. Factors influencing acute high-grade restenosis in emergency percutaneous transluminal coronary angioplasty for acute myocardial infarction.

    OpenAIRE

    Kusachi, Shozo; Iwasaki,Kohichirou; Nishiyama, Osamu; Ueda, Minoru; Kita, Toshimasa; Hata,Takato; Taniguchi, Gyou; Watanabe, Hirofumi; Hina, Kazuyoshi; Saito, Daiji; Tsuji, Takao; Haraoka,Shoichi

    1989-01-01

    We studied the factors which may induce acute high grade restenosis in emergency percutaneous transluminal coronary angioplasty (PTCA). PTCA was attempted in 50 patients with acute myocardial infarction, and the balloon catheter passed successfully across the occlusion site in 47 (94%) of the patients. These 47 patients were analyzed. "Acute restenosis" was defined as a lesion which was revascularized to less than 50% luminal reduction narrowed again to more than 75% luminal reduction...

  19. Effect of endovascular primary stent-assisted angioplasty on atherosclerotic intracranial stenosis

    International Nuclear Information System (INIS)

    Objective: To analyse the preliminary outcome and its relevant factors of endovascular stent-assisted angioplasty for intracranial stenosis. Methods: Sixty-one atherosclerotic intracranial stenosis in 57 patients (23 stenosis in posterior and 38 in anterior circulation) were treated with endovascular angioplasty using balloon-expandable coronary stents. Results: Technical success was achieved in all patients, with no procedural and associated complications except one of intracranial hemorrhage. Angiographic results immediately after stenting suggested that the residual postprocedure stenosis was 0%-32% (mean 8.7% ± 4.4%), with significant reduction from preprocedure stenosis (74.5% ± 6.7%). The patients were clinically asymptomatic and had no recurrent TIA and stroke. Follow-up angiogram in 43 patients revealed no restenosis (<50%), though 3 patients revealed mild endothelial hyperplasia. Conclusions: Endovascular stenting for intracranial stenosis is safe and feasible, and would be favorable for decreasing incidence of stroke during short-term follow up

  20. Clinical effects of intracoronary brachytherapy on diffuse in-stent restenosis after coronary angioplasty

    International Nuclear Information System (INIS)

    Objective: To investigate the effect of intracoronary brachytherapy using 90Sr/90Yon in-stent restenosis in patients with coronary disease. Methods: Thirty-nine patients (male 29, female 10) with in-stent restenosis after percutaneous coronary intervention (PCI) were studied. The patients were divided randomly into two groups: single-balloon group (21 cases, control group) and brachytherapy group (18 cases, treatment group). All the lesions were treated with balloon angioplasty satisfactorily. After that the patients in treatment group took a brachytherapy using the Beta-Cath system (Novoste). After the operation, there was a 9-months follow-up. Results: Within the follow-up, one case (5.6%) in treatment group was found to be with in-stent restenosis and 8 cases(38.1%) in control group. There was significant difference between the two groups (P= 0.006). Conclusion: The brachytherapy using 90Sr/90Y after balloon angioplasty is safe, effective and feasible for containing diffuse in-stent restenosis in patients. (authors)

  1. Study on the dynamic change of endothelin and the effect of treatment by captopril in the development of stenosis of aorta after balloon injury in rabbits

    International Nuclear Information System (INIS)

    Objective: To study the dynamic change of endothelin (ET) in the blood, the pathological change, and the ET-IR (ET-immunoreaction, ET-IR) in the development of stenosis after balloon injury of rabbit aorta, and to investigate the effect of captopril on the prevention of restenosis after transluminal angioplasty. Methods: According to the different time of being killed after micro-balloon angioplasty, 48 rabbits were divided randomly into 6 groups such as 6-hour group, 1-day group, 3-day group, 7-day group, 15-day group, and 22-day group. 6 out of 8 rabbits of each group were created models of aortic endothelium injury by micro-balloon angioplasty, and 3 of them were given captopril (2 mg·kg-1·d-1 p. o.) from 1 day before balloon injury to the day being killed. The rest 2 rabbits in each group were controls. ET level in the plasma was measured by ELISA before, as well as after micro-balloon angioplasty, and pathomorphological examination of local aorta was carried out to observe the intimal thickness and the extent of lumen stenosis, and ET-IR was assessed by immunohistochemical technique in the aortic wall. Results: (1) The major change of vascular stenosis was the proliferation of vascular smooth muscle cell (VSMC) and endothelium. (2) ET levels in the plasma and ET-IR in the local aortic wall were significantly increased after micro-balloon angioplasty. (3) The intimal thickness and extent of lumen stenosis in the group of medical treatment by captopril were significantly lower than those in injury group. Conclusions: The experimental results show that the major pathologic change of vascular stenosis is the significant proliferation of VSMC and endothelium. Further more, ET is a key factor in the development of vascular stenosis, and captopril can prevent restenosis after angioplasty. (author)

  2. Balloon-assisted ultrasound-guided direct percutaneous embolization of a peripheral pseudoaneurysm with n-butyl cyanoacrylate

    International Nuclear Information System (INIS)

    We report the ultrasound-guided direct percutaneous injection of n-butyl cyanoacrylate to embolize an iatrogenic peripheral pseudoaneurysm secondary in a 33-year-old patient undergoing hemodialysis. We protected the parent artery with inflation of an angioplasty balloon across the neck during the cyanoacrylate injection. Complete occlusion of the pseudoaneurysm was achieved without ischemic complication. (orig.)

  3. Carotid angioplasty with cerebral protection

    International Nuclear Information System (INIS)

    Background. Carotid endarterectomy (CEA) is widely used in the management of high-grade carotid stenosis. It is a surgical procedure requiring general anaesthesia and is suitable only for lesions located at or close to the carotid bifurcation. It may develop complications, such as stroke, death, cranial nerve palsies, wound haematoma and cardiac complications. The risk of complications is increased in patients with recurrent carotid artery stenosis following CEA, in subjects undergoing radiotherapy to the neck, and in patients with cardiopulmonary disease. The drawbacks of CEA have led physicians to search for alternative treatment options. Carotid angioplasty and stenting (CAS) is less invasive than CEA. The method is particularly suitable for the treatment of recurrent stenosis after previous CEA and distal internal artery stenosis, which is inaccessible for CEA. CAS does not cause cranial nerve palsies. Moreover, it does not require general anaesthesia and causes lower morbidity and mortality in patients with severe cardiopulmonary disease. The complications of CAS include stroke due to distal immobilisation of a plaque or thrombus dislodged during the procedure, abrupt vessel occlusion due to thrombosis, dissection or vasospasm, and restenosis due to intimal hyperplasia. CAS is a relatively new procedure; therefore, it is essential to establish its efficacy and safety before it is introduced widely into clinical practice. Patients and methods. In Slovenia, we have also started with carotid angioplasty by the study: Slovenian Carotid Angioplasty Study (SCAS). We performed CAS in 17 patients (12 males and 5 females) aged from 69 to 82 years. All patients were symptomatic with stenosis greater than 70 %. 10 patients suffered transient ischemic attacks, 4 patients minor strokes and 3 patients amaurosis fugax. Results. Technical success (< 30 % residual stenosis) was achieved in all cases. In 14 patients, no residual stenosis was found, in 2 patients a 15 % residual

  4. Below-the-ankle Angioplasty and Stenting for Limb Salvage: Anatomical Considerations and Long-term Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Diamantopoulos, Athanasios; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris [School of Medicine, Patras University Hospital, Department of Interventional Radiology (Greece)

    2013-08-01

    PurposeTo report the long-term angiographic and clinical results in a series of below-the-ankle (BTA) angioplasty procedures and to present some biomechanical issues related to the unique anatomical geometry of the ankle.MethodsWe performed a retrospective analysis of BTA angioplasty procedures. Clinical end points included technical success, patient mortality, salvage of the treated foot, and repeat target lesion revascularization. Imaging end points included primary patency, binary restenosis of the target lesion at the 50 % threshold, and stent integrity (stent fracture, deformation, or collapse). Univariate subgroup analysis was performed.ResultsIn total, 40 limbs in 37 patients (age 73.5 {+-} 8.2 years) with critical limb ischemia were included and 42 inframalleolar lesions (4.2 {+-} 1.4 cm) were analyzed. Technical success was achieved in 95.2 % (40 of 42). Provisional stent placement was performed in 45.2 % (19 of 42). Two patients died, and two major amputations occurred up to 3 years. At 1 year, overall primary vessel patency was 50.4 {+-} 9.1 %, lesion binary restenosis rate was 64.1 {+-} 8.3 %, and repeat intervention-free survival was 93.6 {+-} 4.3 % according to life table analysis of all treated lesions. Pairwise subgroup analysis showed that BTA self-expanding stents were associated with significantly higher restenosis and poorer primary patency compared to plain balloon angioplasty or sirolimus-eluting balloon-expandable stents. Significant deformation and/or fracture of balloon-expandable stents placed BTA were identified in five of 11. Dynamic imaging showed that the dorsalis pedis artery is kinked during foot dorsiflexion, whereas the distal posterior tibial artery is kinked during plantar flexion of the foot.ConclusionBTA angioplasty for critical limb ischemia treatment is safe and feasible with satisfactory long-term results. BTA stent placement must be reserved for bailout indications.

  5. Sleep Apnea Tied to Complications After Angioplasty

    Science.gov (United States)

    ... page: https://medlineplus.gov/news/fullstory_159391.html Sleep Apnea Tied to Complications After Angioplasty Nightly breathing ... 15, 2016 WEDNESDAY, June 15, 2016 (HealthDay News) -- Sleep apnea may increase the risk of serious complications ...

  6. Restenosis following balloon dilation of benign esophageal stenosis

    Institute of Scientific and Technical Information of China (English)

    Ying-Sheng Cheng; Ming-Hua Li; Ren-Jie Yang; Hui-Zhen Zhang; Zai-Xian Ding; Qi-Xin Zhuang; Zhi-Ming Jiang; Ke-Zhong Shang

    2003-01-01

    AIM: To elucidate the mechanism of restenosis following balloon dilation of benign esophageal stenosis.METHODS: A total of 49 rats with esophageal stenosis were induced in 70 rats using 5 ml of 50 % sodium hydroxide solution and the double-balloon method, and an esophageal restenosis (RS) model was developed by esophageal stenosis using dilation of a percutaneous transluminal coronary angioplasty (PTCA) balloon catheter. These 49 rats were divided into two groups: rats with benign esophageal stricture caused by chemical burn only (control group, n=21) and rats with their esophageal stricture treated with balloon catheter dilation (experimental group, n=28). Imaging analysis and immunohistochemistry were used for both quantitative and qualitative analyses of esophageal stenosis and RS formation in the rats, respectively.RESULTS: Cross-sectional areas and perimeters of the esophageal mucosa layer, muscle layer, and the entire esophageal layers increased significantly in the experimental group compared with the control group. Proliferating cell nuclear antigen (PCNA) was expressed on the 5th day after dilation, and was still present at 1 month. Fibronectin (FN)was expressed on the 1st day after dilation, and was still present at 1 month.CONCLUSION: Expression of PCNA and FN plays an important role in RS after balloon dilation of benign esophageal stenosis.

  7. Percutaneous transluminal angioplasty and stenting of carotid arteries: Early results

    Directory of Open Access Journals (Sweden)

    Čolić Momčilo

    2008-01-01

    Full Text Available INTRODUCTION Treatment of carotid stenosis could be surgical: eversion endarterectomy, conventional endarterectomy and patch-plasty, resection with graft interposition and bypass procedure or, in the past few years, carotid artery angioplasty (PTA with stent implantation. OBJECTIVE The aim of this study is to present early results of carotid artery angioplasty and stenting, as well as to identify indications for this procedure. METHOD Twenty-three patients with stenosis of internal carotid artery were included in the prospective study which was performed in the period from July 2006 to July 2007. For PTA and stenting of the carotid artery we used Balloon dilatation catheter Ultra-softTM SV and Carotid WallstentTM MonorailTM. During the procedure, brain protection by embolic protection system Filter Wire EZ was essentially performed. Descriptive statistical methods were performed to present and describe the patient characteristics, risk factors and results. RESULTS 23 patients were examined. In four (17.39% cases there was asymptomatic, while in 19 (82.61% there was symptomatic homodynamic significant stenosis of the internal carotid artery. Four of these 19 patients (17.39% had late restenosis following carotid endarterectomy, four (17.39% important respiratory failure, and 11 (47.83% important heart disease. Patients were followed up for the first 30 postopertive days. In that period, there were no mortality and no needs for surgical conversions. In one case (4.35%, residual stenosis of 30% remained. Two patients (8.70% had TIA and one (4.35% had CVI. CONCLUSION Main indications for PTA and stenting of carotid arteries are: surgically inaccessible lesions (at or above C2; or subclavial; radiation-induced carotid stenosis; prior ispilateral radical neck dissection; prior carotid endarterectomy (restenosis, severe cardiac and pulmonary conditions. Limitations and contraindications to carotid angioplasty and stentning include: significant

  8. Recanalization by means of laser and angioplasty in atherosclerotic lesions of the lower limbs

    International Nuclear Information System (INIS)

    From January to November 1989, 31 iliac and femoro-popliteal atherosclerotic lesions were treated in 29 patients (age range: 33-80 years) by means of percutaneous laser-assisted angioplasty. The lesions were 6 iliac tubolar stenoses, 6 iliac occlusions and 19 femoro-popliteal occlusions, 2-20 cm long. The laser equipment employed was in 10 cases a Cardiolase 4000 Nd: YAG 'hot tip' unit, and in 21 cases a Nd: YAG 'sapphire contact probe' unit. Initial success was achieved in 23/31 lesions (74%); the follow-up, by clinical examination, Doppler US, and ankle-arm pressure index performed every 4ty month, showed 1-year actuarial patency of 80% for femoro-popliteal occlusion and 100% for iliac lesion, with 87% cumulative patency. Overall complication rate was 22.5%. There were 6 local complications, 4 of which were hematomas at the arterial puncture site, and 2 were perforation of the superficial femoral artery, all without any clinical sequelae; one patient developed rethrotrombosis within 72 hours from treatment,which needed amputation after an emergency bypass. Preliminary results show no significant improvement when compared with conventional balloon angioplasty results both in immediate success rate and in short-to-midterm patency; furthermore, laser therapy was burdened by a higher complication rate. We believe that laser angioplasty should be employed only in arterial occlusion uncrossable with angiographic guidance alone

  9. The role of the adventitia in the arterial response to angioplasty: the effect of intravascular radiation

    International Nuclear Information System (INIS)

    Purpose: In the current series of experiments we have characterized cell proliferation leading to vascular lesion formation in a porcine model for post-angioplasty restenosis and examined the mechanism of action of intravascular beta irradiation in the prevention of lesion formation in this model. Methods and Materials: Juvenile male pigs were subjected to balloon overstretch injury of the left anterior descending and circumflex coronary arteries using clinical angioplasty catheters. Proliferating cells were labelled by injections of 50 mg/kg of bromo-deoxyuridine (BrDU) 24, 16 and 8 hrs prior to sacrifice and were detected by immunohistochemistry using a specific antibody to BrDU. In some cases, BrDU was given as a pulse 3 days after angioplasty and the animals sacrificed on day 14 to follow the migration of the cells which had proliferated earlier. Characterization of the proliferating cells was performed by immunohistochemistry using antibodies to specific cytoskeletal proteins specific for smooth muscle cells and myofibroblasts. Some vessels were treated at the time of angioplasty with 14 or 28 Gy (to a depth of 2 mm) intravascular irradiation using a flexible catheter with a pure beta emitter 90 SR/Y and the effect on cell proliferation and terminal transferase-mediated UTP nick-end labelling (TUNEL) examined 3 or 7 days later. Results: The first major site of cell proliferation between 2-3 days after angioplasty is the adventitia and not the medial wall. Seven days after angioplasty cell proliferation is predominant in the neointima and is reduced in the media and adventitia. Differential staining with antibodies directed against smooth muscle alpha actin and other cytoskeletal proteins indicates that the proliferating adventitial cells are myofibroblasts. Pulse label studies with BrDU indicates that the proliferating adventitial myofibroblasts migrate into the neointima and contribute to the mass of the restenosis lesion. Fourteen days after angioplasty the

  10. Weather Balloon Ascent Rate

    Science.gov (United States)

    Denny, Mark

    2016-05-01

    The physics of a weather balloon is analyzed. The surprising aspect of the motion of these balloons is that they ascend to great altitudes (typically 35 km) at a more or less constant rate. Such behavior is not surprising near the ground—say for a helium-filled party balloon rising from street level to the top of the Empire State building—but it is unexpected for a balloon that rises to altitudes where the air is rarefied. We show from elementary physical laws why the ascent rate is approximately constant.

  11. Initial clinical experience with a new pulsed dye laser device in angioplasty of limb ischemia and shunt fistula obstructions

    International Nuclear Information System (INIS)

    Selective plaque ablation with laser radiation at 405-530 nm in vitro has been reported. The possibilities are investigated of a new pulsed dye laser device for in vivo recanalization of arteries in ischemic lower limbs and stenoses/occlusions of arterio-venous hemo-dialysis shunt fistulae. A specially designed 9F or 7F multifiber catheter was used for treatment of 10 patients with lower limb artery obliterations and 11 patients with malfunctioning hemodialysis access fistulae (HAF). The recanalization technical success was 5/5 in the iliac arteries (IA), 4/5 in the superficial femoral arteries (SFA), and 11/11 in the HAF. Early re-occlusions occurred in one SFA and IA, respectively, caused by very bad run-off. There was one clinically insignificant SFA perforation. Additional balloon angioplasty was considered necessary in 10/16 lesions. Mean ankle-arm index increased from 0.68 to 0.97. With two exceptions all HAF patients were re-integrated in the dialysis program. Pulsed dye laser angioplasty promises to be an effective and fast method for plaque ablation debulking. The first clinical experience confirms previous in vitro results. In particular laser recanalization may become the method of choice for treatment of rigid HAF obstructions and it seems to be superior to vascular surgery or balloon angioplasty alone. (author). 15 refs.; 2 figs

  12. Laser angioplasty using a lensed-fiber delivery system and a pulsed Nd:YAG laser: early clinical results

    Science.gov (United States)

    White, Christopher J.; Ramee, Stephen R.; Mesa, Juan E.; Hollier, Larry H.; Murgo, Joseph P.; Aita, Michael; Samson, Gene; Godfrey, Maureen A.

    1990-07-01

    We performed a clinical trial to evaluate the safety and efficacy of a unique lensed-fiber delivery system with a pulsed Neodymium-yttrium aluminum garnet (Nd-YAG) laser in patients with atherosclerotic peripheral vascular disease. The lensed-fiber consists of a spherical silica lens, 1 .5 mm in diameter, mounted at the distal tip of a 300 im silica optical fiber. The Nd-YAG laser is pulsed at 10 Hz, and we delivered 0.5 J/pulse with a pulse duration of 100 msecs in 2- to 5-second bursts. Successful recanalization of stenoses or occlusions was obtained in 9 of 10 patients and was manifested by improvement in blood flow as measured angiographically and with ankle-brachial blood pressure index improvement (> 0. 15). There were no arterial perforations or dissections associated with the laser angioplasty. All successfully recanalized patients required adjunctive balloon angioplasty to obtain a satisfactory reduction in luminal diameter stenosis of the treated artery. We conclude that this unique delivery system and the pulsed Nd-YAG laser are a safe and effect method of recanalizing arterial stenoses not amenable to conventional balloon angioplasty alone.

  13. The Application of Dual-wire Balloon in The Treatment of Coronary Bifurcation Lesions

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Objectives To assess the efficiency and safety of dual-wire balloon angioplasty side branch combined stenting the main branch in the treatment of coronary bifurcation lesions. Methods This study included thirty-six patients with 41 coronary bifurcation lesions. Selective dual-wire balloon angioplasty was performed in side branch and/or in main branch, and implantation of stents was performed in main branch only. Clinical outcome and major adverse cardiac events were observed inhospital and follow-up. Results Success rate of side branch dilatation before main branch stenting was 100%; main branch direct stenting performed in 4 cases; success main branch dilatation performed in the other 37 cases; kissing technique was performed successfully in 5 cases, which side branch was jailed after main branch stenting with TIMI grade 0-2 flow. No Q-wave myocardial infarction, acute revascularization and death occurred during in-hospital.Clinical follow-up was available in all patients. No Q-wave myocardial infarction, revascularization and death occurred, angina pectoris recurred in three patients,released by strengthen drug treatment. Conclusions Dual-wire balloon angioplasty side branch combined stenting the main branch is simple, safe and effective for the treatment of coronary bifurcation lesions.

  14. Roles of thrombin and platelet membrane glycoprotein IIb/IIIa in platelet-subendothelial deposition after angioplasty in an ex vivo whole artery model

    International Nuclear Information System (INIS)

    Platelet deposition at the site of injury caused by balloon angioplasty is associated with acute closure and restenosis. In a new ex vivo whole artery angioplasty model, the authors examined the roles of thrombin inhibition with D-Phe-Pro-ArgCH2Cl (PPACK) and inhibition of the platelet membrane fibrinogen receptor glycoprotein IIb/IIIa (GPIIb/IIIa) with monoclonal antibody 7E3 on platelet deposition at the site of balloon injury. Fresh rabbit aortas were mounted in a perfusion chamber. One half of the mounted arterial segment was dilated with a standard angioplasty balloon catheter and the uninjured half served as the control segment. The vessels were perfused with human blood at physiological pressure and shear rates of 180-250 second-1 for 30 minutes. Platelet deposition was measured using 111In-labeled platelets and scanning electron microscopy. With heparin (2 units/ml) anticoagulation, 8.2 ± 2.2 x 10(6) platelets/cm2 were deposited at the site of balloon injury compared with 0.7 ± 0.2 x 10(6) platelets/cm2 on uninjured segments (p less than 0.02, n = 7). PPACK was tested at a concentration (10 microM) that totally inhibited platelet aggregation in response to thrombin. 7E3 was tested at a concentration (10 micrograms/ml) that totally inhibited platelet aggregation. Platelet deposition at the site of balloon injury was reduced 47% by PPACK and 70% by 7E3 compared with heparin. At shear rates seen in nonstenotic coronary arteries, PPACK and 7E3 are more effective than heparin in reducing platelet deposition at the site of balloon injury. The significant inhibition of platelet deposition by PPACK demonstrates the importance of heparin-resistant thrombin in platelet thrombus formation

  15. Angioplasty of a persistent sciatic artery: case report Angioplastia de artéria isquiática persistente: relato de caso

    OpenAIRE

    Denis Szejnfeld; Sergio Quilici Belczak; Igor Rafael Sincos; Ricardo Aun

    2011-01-01

    Transluminal balloon angioplasty is a good choice for the treatment of lower limb arterial occlusion. Although there are some guidelines addressing its indications, some situations are so unusual that there is no consensus on their management. The presence of a persistent sciatic artery is a rare congenital anomaly of the circulatory system and may be associated with early atheromatous degeneration and occlusion. The authors describe the case of an 81-year-old woman that presented with a hist...

  16. Bursting water balloons

    CERN Document Server

    Lund, Hugh M

    2011-01-01

    The impact and rupture of water-filled balloons upon a flat, rigid surface is studied experimentally, for which three distinct stages of the flow are observed. Due to the impact, waves are formed on the balloon's surface for which the restoring force is tension in the latex. Immediately following rupture of the membrane, a shear instability created by the retraction of the balloon is observed. At later times, a larger-scale growth of the interfacial amplitude is observed, that may be regarded as a manifestation of a phenomenon known as the Richtmyer-Meshkov instability. This flow is closely related to the classical understanding of the Richtmyer-Meshkov instability for when there exists a density difference between the fluids inside and outside the balloon. Further, it is shown experimentally that this growth of the interface may also occur when there is no density difference across the balloon, a situation that does not arise for the standard Richtmyer-Meshkov instability.

  17. Balloon dacryocystoplasty study in the management of adult epiphora.

    LENUS (Irish Health Repository)

    Fenton, S

    2012-02-03

    PURPOSE: To determine the efficacy of dacryocystoplasty with balloon dilation in the treatment of acquired obstruction of the nasolacrimal system in adults. METHODS: Balloon dacryocystoplasty was performed in 52 eyes of 42 patients under general anaesthetic. A Teflon-coated guidewire was introduced through the canaliculus and manipulated through the nasolacrimal system and out of the nasal aperture. A 4 mm wide 3 cm coronary angioplasty balloon catheter was threaded over the guidewire in a retrograde fashion and dilated at the site of obstruction. RESULTS: There was complete obstruction in 30% of cases and partial obstruction in 70%. The most common site of obstruction was the nasolacrimal duct. The procedure was technically successful in 94% of cases. The overall re-obstruction rate was 29% within 1 year of the procedure. There was an anatomical failure rate of 17% for partial obstruction and 69% for complete obstruction within 1 year. CONCLUSIONS: Balloon dacryocystoplasty has a high recurrence rate. There may be a limited role for this procedure in partial obstructions. Further refinements of the procedure are necessary before it can be offered as a comparable alternative to a standard surgical dacryocystorhinostomy.

  18. Transluminal angioplasty, fibrinolysis, and newer vascular interventions

    International Nuclear Information System (INIS)

    This refresher course presents an overview of the current status of transluminal angioplasty in the treatment of peripheral vascular disease, renovascular hypertension, and upper extremity vasculature. Indications for therapy, accepted techniques, and the diagnosis and treatment of complications are major topic areas. Newer areas of increasing application are discussed, particularly popliteal and tibial angioplasty. Newer devices and procedures such as lasers, percutaneous atherectomy, and mechanical recanalization devices are reviewed and their role in the current therapeutic armamentarium discussed. The current status of catheter-directed fibrinolytic techniques is presented, particularly as they relate to the concomitant use of transluminal angioplasty. The choice of lytic agents and newer agents is reviewed. Long-term results and complication rates are discussed by anatomic area

  19. Holmium:YAG laser angioplasty: treatment of acute myocardial infarction

    Science.gov (United States)

    Topaz, On

    1993-06-01

    We report our clinical experience with a group of 14 patients who presented with acute myocardial infarction. A holmium:YAG laser was applied to the infarct-related artery. This laser emits 250 - 600 mJ per pulse, with a pulse length of 250 microseconds and repetition rate of 5 Hz. Potential benefits of acute thrombolysis by lasers include the absence of systemic lytic state; a shortened thrombus clearing time relative to using thrombolytics; safe removal of the intracoronary thrombus and facilitation of adjunct balloon angioplasty. Potential clinical difficulties include targeting the obstructive clot and plaque, creation of debris and distal emboli and laser-tissue damage. It is conceivable that holmium:YAG laser can be a successful thrombolytic device as its wave length (2.1 microns) coincides with strong water absorption peaks. Since it is common to find an atherosclerotic plaque located under or distal to the thrombotic occlusion, this laser can also be applied for plaque ablation, and the patient presenting with acute myocardial infarction can clearly benefit from the combined function of this laser system.

  20. MR-Guided Percutaneous Angioplasty: Assessment of Tracking Safety, Catheter Handling and Functionality

    International Nuclear Information System (INIS)

    Purpose: Magnetic resonance (MR)-guided percutaneous vascular interventions have evolved to a practical possibility with the advent of open-configuration MR systems and real-time tracking techniques. The purpose of this study was to assess an MR-tracking percutaneous transluminal angioplasty (PTA) catheter with regard to its safety profile and functionality. Methods: Real-time, biplanar tracking of the PTA catheter was made possible by incorporating a small radiofrequency (RF) coil in the catheter tip and connecting it to a coaxial cable embedded in the catheter wall. To evaluate potentially hazardous thermal effects due to the incorporation of the coil, temperature measurements were performed within and around the coil under various scanning and tracking conditions at 1.5 Tesla (T). Catheter force transmission and balloon-burst pressure of the MR-tracking PTA catheter were compared with those of a standard PTA catheter. The dilatative capability of the angioplasty balloon was assessed in vitro as well as in vivo, in an isolated femoral artery segment in a swine. Results: The degree of heating at the RF coil was directly proportional to the power of the RF pulses. Heating was negligible with MR tracking, conventional spin-echo and low-flip gradient-echo sequences. Sequences with higher duty cycles, such as fast spin echo, produced harmful heating effects. Force transmission of the MR-tracking PTA catheter was slightly inferior to that of the standard PTA catheter, while balloon-burst pressures were similar to those of conventional catheters. The MR-tracking PTA catheter functioned well both in vitro and in vivo. Conclusion: The in vivo use of an MR-tracking PTA catheter is safe under most scanning conditions

  1. Balloon Design Software

    Science.gov (United States)

    Farley, Rodger

    2007-01-01

    PlanetaryBalloon Version 5.0 is a software package for the design of meridionally lobed planetary balloons. It operates in a Windows environment, and programming was done in Visual Basic 6. By including the effects of circular lobes with load tapes, skin mass, hoop and meridional stress, and elasticity in the structural elements, a more accurate balloon shape of practical construction can be determined as well as the room-temperature cut pattern for the gore shapes. The computer algorithm is formulated for sizing meridionally lobed balloons for any generalized atmosphere or planet. This also covers zero-pressure, over-pressure, and super-pressure balloons. Low circumferential loads with meridionally reinforced load tapes will produce shapes close to what are known as the "natural shape." The software allows for the design of constant angle, constant radius, or constant hoop stress balloons. It uses the desired payload capacity for given atmospheric conditions and determines the required volume, allowing users to design exactly to their requirements. The formulations are generalized to use any lift gas (or mixture of gases), any atmosphere, or any planet as described by the local acceleration of gravity. PlanetaryBalloon software has a comprehensive user manual that covers features ranging from, but not limited to, buoyancy and super-pressure, convenient design equations, shape formulation, and orthotropic stress/strain.

  2. The Descending Helium Balloon

    Science.gov (United States)

    Helseth, Lars Egil

    2014-01-01

    I describe a simple and fascinating experiment wherein helium leaks out of a rubber balloon, thereby causing it to descend. An estimate of the volumetric leakage rate is made by measuring its rate of descent.

  3. Primary coronary angioplasty in acute myocardial infarction.

    OpenAIRE

    Grech, E. D.; Ramsdale, D. R.

    1996-01-01

    It is well established that recanalisation of the infarct-related artery is of great benefit in the early hours after acute myocardial infarction. This can be achieved by the use of thrombolytic agents and/or by percutaneous transluminal coronary angioplasty (PTCA). This article reviews data on the role of primary PTCA and summarises current opinion on its use.

  4. Resistive ballooning mode equation

    Energy Technology Data Exchange (ETDEWEB)

    Bateman, G.; Nelson, D. B.

    1978-10-01

    A second-order ordinary differential equation on each flux surface is derived for the high mode number limit of resistive MHD ballooning modes in tokamaks with arbitrary cross section, aspect ratio, and shear. The equation is structurally similar to that used to study ideal MHD ballooning modes computationally. The model used in this paper indicates that all tokamak plasmas are unstable, with growth rate proportional to resistivity when the pressure gradient is less than the critical value needed for ideal MHD stability.

  5. New developments in the clinical use of drug-coated balloon catheters in peripheral arterial disease

    Science.gov (United States)

    Naghi, Jesse; Yalvac, Ethan A; Pourdjabbar, Ali; Ang, Lawrence; Bahadorani, John; Reeves, Ryan R; Mahmud, Ehtisham; Patel, Mitul

    2016-01-01

    Peripheral arterial disease (PAD) involving the lower extremity is a major source of morbidity and mortality. Clinical manifestations of PAD span the spectrum from lifestyle limiting claudication to ulceration and gangrene leading to amputation. Advancements including balloon angioplasty, self-expanding stents, drug-eluting stents, and atherectomy have resulted in high technical success rates for endovascular therapy in patients with PAD. However, these advances have been limited by somewhat high rates of clinical restenosis and clinically driven target lesion revascularization. The recent introduction of drug-coated balloon technology shows promise in limiting neointimal hyperplasia induced by vascular injury after endovascular therapies. This review summarizes the contemporary clinical data in the emerging area of drug-coated balloons.

  6. Percutaneous coronary excimer laser angioplasty in patients with stable and unstable angina pectoris. Acute results and incidence of restenosis during 6-month follow-up.

    Science.gov (United States)

    Karsch, K R; Haase, K K; Voelker, W; Baumbach, A; Mauser, M; Seipel, L

    1990-06-01

    A clinical study was conducted to evaluate the efficacy and safety of percutaneous coronary excimer laser angioplasty in 60 patients with coronary artery disease. Forty-nine patients had stable exertional angina, and 11 patients had unstable angina despite medical therapy. A novel 1.4-mm diameter catheter with 20 quartz fibers of 100-microns diameter each arranged concentrically around a central lumen suitable for a 0.014-in. flexible guide wire was coupled to an excimer laser. A commercial excimer laser emitting energy at a wavelength of 308 nm with a pulse duration of 60 nsec was used. The laser was operated at 20 Hz. Mean energy transmission was 30 +/- 5 mJ/mm2. In five of the 60 patients, laser angioplasty was not attempted. In 23 patients with laser ablation alone, percent stenosis decreased from 76 +/- 14% before to 27 +/- 17% after ablation and was 34 +/- 15% at the early follow-up angiogram. In 32 patients, additional balloon angioplasty was performed because of vessel closure after laser ablation in 11 and an insufficient qualitative result in 21 patients. Of the 11 patients with unstable angina, one patient died due to vessel closure 3 hours after intervention, and two patients developed a myocardial infarction. In 22 of 47 patients with late follow-up angiography, restenosis within the 6-month follow-up period occurred. Rate of restenosis was higher in patients treated with laser ablation and balloon angioplasty (16 of 28) than in patients treated with laser ablation alone (six of 19). These results suggest that coronary excimer laser angioplasty for ablation of obstructive lesions is feasible and safe in patients with stable angina. However, development of new catheter systems is necessary for an improved success rate. PMID:2344680

  7. Intervention with rotational atherectomy, sharp balloon and implant of conventional Stent in ostium lesion of right coronary artery, calcified

    International Nuclear Information System (INIS)

    Atherosclerotic lesions from the right coronary artery ostium have a low incidence in the manifestation of coronary disease. The high content of smooth muscle cells in the coronary ostium is related to a low success probability of a percutaneous intervention. We present a clinical complex case of a 61 years old female with right coronary artery ostium disease to whom we performed an angioplasty with cutting balloon and rotational arterectomy with successful results

  8. [Coronary angioplasty in elderly patients].

    Science.gov (United States)

    Liistro, Francesco; Colombo, Antonio

    2002-01-01

    effect on the long-term outcome. These considerations could be "out of time" if the results obtained with the use of drug-eluting stents observed in selected patient populations will be confirmed in larger trials and in routine clinical practice. Whereas the advantages of the percutaneous versus the surgical approach in the elderly have not been fully clarified in patients with stable or unstable angina, primary angioplasty appears to be a very promising strategy in old patients with acute myocardial infarction. The improved clinical success with percutaneous revascularization in the elderly (acute mortality in patients > 85 years: 28.4% reperfused vs 38.5% not reperfused; p = 0.001) has to be related to the use of stents and to IIb/IIIa antagonists. In conclusion, when an old patient needs myocardial revascularization, the percutaneous approach should, in our opinion, be considered the treatment of choice in subjects either with stable or unstable angina and in those with acute myocardial infarction. At present, surgical revascularization provides better results in diabetic patients. The advent of drug-eluting stents may change many of the current limitations of percutaneous revascularization and further expand the use of this strategy. PMID:11899566

  9. A clinical study on perforator stroke resulting from Wingspan stent angioplasty for symptomatic intracranial artery stenosis

    International Nuclear Information System (INIS)

    Objective: To evaluate the incidence, potential hazards and effective countermeasure for perforator stroke (PS) resulting from stent angioplasty of symptomatic intracranial artery stenosis. Methods: Peri-operation PS complications of 258 patients receiving Gateway balloon-Wingspan stenting for severe symptomatic intracranial stenosis were analyzed. The incidence, clinical course, and prognosis of PS resulting from stenting were recorded. Special attention was given to the anatomical features, clinical manifestation and video materials of patients with PS. χ2 test was used for statistics. Results: Two hundred and fifty-five patients received stent angioplasty successfully and 7 patients had PS (incidence rate 2.7%). The patients with basilar artery stenosis had a higher incidence of PS resulting from intracranial stenting (6.1%, 4/66) than patients with middle cerebral artery stenosis (2.5%, 3/118) (χ2=2.320, P= 0.025). The potential hazards for PS included preoperative perforator stroke adjacent to the stenotic segment and prominent dissection during operation. Six patients presented symptoms after awake from general anaesthesia and one had symptoms 3 hours after stenting. One deteriorated gradually and the others reached the maximum deficit almost at once. At the follow-up of 3 months, 3 patients were disabled and scored one, two, two by mRS respectively. Conclusion: The incidence of PS resulting from intracranial stenting was low and the prognosis was not disastrous. Stenosis at basilar artery and preoperative perforator stroke adjacent to the stenotic segment were potential risk factors for PS complication. Proper maneuver of angioplasty may decrease the incidence of PS and improve the prognosis. (authors)

  10. Universal stratospheric balloon gradiometer

    Science.gov (United States)

    Tsvetkov, Yury; Filippov, Sergey; Brekhov, Oleg; Nikolaev, Nikolay

    The study of the interior structure of the Earth and laws of its evolution is one of the most difficult problems of natural science. Among the geophysical fields the anomaly magnetic field is one of the most informational in questions of the Earth’s crust structure. Many important parameters of an environment are expedient for measuring at lower altitudes, than satellite ones. So, one of the alternatives is stratospheric balloon survey. The balloon flight altitudes cover the range from 20 to 50 km. At such altitudes there are steady zone air flows due to which the balloon flight trajectories can be of any direction, including round-the-world (round-the-pole). For investigation of Earth's magnetic field one of the examples of such sounding system have been designed, developed and maintained at IZMIRAN and MAI during already about 25 years. This system consists of three instrumental containers uniformly placed along a vertical 6 km line. Up today this set has been used only for geomagnetic purposes. So we describe this system on example of the measuring of the geomagnetic field gradient. System allows measuring a module and vertical gradient of the geomagnetic field along the whole flight trajectory and so one’s name is - stratospheric balloon magnetic gradiometer (SMBG). The GPS-receivers, located in each instrumental container, fix the flight coordinates to within several tens meters. Process of SBMG deployment, feature of the exit of rope from the magazine at the moment of balloon launching has been studied. Used magazine is cellular type. The hodograph of the measuring base of SBMG and the technique of correction of the deviations of the measuring base from the vertical line (introduction of the amendments for the deviation) during the flight have been investigated. It is shown that estimation of the normal level of values of the vertical gradient of the geomagnetic field is determined by the accuracy of determining the length of the measuring base SBMG

  11. Peripheral macroembolism complicating laser angioplasty of arteries of extremities - therapy with radiologic interventional methods

    International Nuclear Information System (INIS)

    From 1987 to 1989 in the Barmherzige Brueder Hospital in Linz/Austria 160 arteries of extremities were treated with laser-assisted balloon dilatation. During these interventions peripheral macroembolism occurred 8 times. The mean length of the recanalised segment was 8.7 cm and thus longer than average (6.5 cm). All 8 cases were successfully treated by aspiration or aspiration combined with local lysis. No adverse effects on long-term results were noted. In 4 cases an early occlusion of the recanalised segment was diagnosed within 48 hours after laser-assisted angioplasty, three times accompanied by embolism. These emboli, too, were removed by aspriation and lysis. To reduce the risk of embolisation strict rules of indication concerning the age of an occlusion have to be observed and mechanical trauma has to be minimised. (orig.)

  12. Venus Altitude Cycling Balloon Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The ISTAR Group ( IG) and team mate Thin Red Line Aerospace (TRLA) propose a Venus altitude cycling balloon (Venus ACB), an innovative superpressure balloon...

  13. Mars Solar Balloon Lander Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Solar Balloon Lander (MSBL) is a novel concept which utilizes the capability of solar-heated hot air balloons to perform soft landings of scientific...

  14. Angioplasty - Multiple Languages: MedlinePlus

    Science.gov (United States)

    ... Chinese - Simplified (简体中文) Chinese - Traditional (繁體中文) French (français) Hindi (हिन्दी) Japanese (日本語) Korean (한국어) Russian (Русский) ... cardiaque - français (French) Bilingual PDF Health Information Translations Hindi (हिन्दी) Heart Cath and and Heart Angioplasty ...

  15. Percutaneous Transluminal Coronary Angioplasty after Cardiac Transplantation

    OpenAIRE

    Avedissian, Michael G.; Bush, Howard S; Leachman, D. Richard; Fighali, Sayid; Frazier, O. H.

    1989-01-01

    This report describes the 1st use of percutaneous transluminal coronary angioplasty in a posttransplant patient at the Texas Heart Institute. The patient, a 44-year-old man, experienced 3 episodes of moderate allograft rejection, hypercholesterolemia, transient severe hyperglycemia, and transient severe renal insufficiency in the posttransplant period. His cholesterol levels became elevated immediately and remained between 200 and 250 mg/dL, despite treatment with gemfibrozil. He had increasi...

  16. Design Issues for Therapeutic Ultrasound Angioplasty Waveguides

    OpenAIRE

    Noone, Declan, (Thesis); Gavin, Graham; McGuinness, Garrett

    2008-01-01

    Therapeutic ultrasound angioplasty is a new minimally invasive cardiovascular procedure for disrupting atherosclerotic lesions. Mechanical energy is transmitted in the form of ultrasound waves via long, flexible wire waveguides navigated to the lesion site through the vascular system. The underpinning principle of this technology is that plaque may be disrupted through a combination of direct contact ablation, pressure waves, cavitation and acoustic streaming, which all depend on the amplitud...

  17. JACEE long duration balloon flights

    International Nuclear Information System (INIS)

    JACEE balloon-borne emulsion chamber detectors are used to observe the spectra and interactions of cosmic ray protons and nuclei in the energy range 1-100A TeV. Experience with long duration mid-latitude balloon flights and characteristics of the detector system that make it ideal for planned Antarctic balloon flights are discussed. 5 refs., 2 figs

  18. Evidence of a cellular protective effect by antecedent angina independent of collateral flow recruitment during coronary angioplasty in humans

    International Nuclear Information System (INIS)

    The main aim of this study was to elucidate whether the beneficial effect of antecedent angina is a cellular protective effect or the result of an increase of collateral flow. Of 42 patients with angina who underwent percutaneous transluminal coronary angioplasty (PTCA) for proximal left anterior descending artery (LAD) stenosis, 22 had experienced antecedent anginal pain (AP) within 7 days prior to PTCA. 99mTc-sestamibi was injected during balloon inflation, and quantitative analysis of ischemic severity during coronary occlusion was calculated (SS). An electrocardiogram was recorded during ballooning to calculate the sum of ST elevation (ΣST). ΣST was significantly reduced in patients with AP compared with patients without AP (1.88±0.89 mV vs 1.18±0.74 mV, p=0.0088); however, no difference was observed in defect severity. A close correlation was observed between SS and ΣST in both groups. The multivariate regression model demonstrated that both a large SS (p<0.0001) and the absence of preceding AP (p=0.001) were significantly related to the elevation of ΣST. Recent angina can render the myocardium more resistant to subsequent ischemia during angioplasty and is true preconditioning rather than simply an increase of flow. (author)

  19. Comments on ideal ballooning

    International Nuclear Information System (INIS)

    Ideal ballooning modes are investigated for the case of plane magnetized slab geometry. Toroidal effects are simulated by a gravitational acceleration periodically varying along magnetic field lines. High shear is shown to be very effective in stabilizing these modes even when field line curvature is most unfavorable to their stability

  20. Critical limb ischaemia in a diabetic population from an Asian Centre: angiographic pattern of disease and 3-year limb salvage rate with percutaneous angioplasty as first line of treatment

    OpenAIRE

    Tan, M; Pua, U; Wong, DES; Punamiya, SJ; Chua, GC; Teo, N

    2010-01-01

    Purpose: Lower extremity amputation prevention (LEAP) is an ongoing program in our institution aimed at salvaging limbs in patients with critical limb ischemia (CLI). Patients in the LEAP program with reconstructible anatomy on initial Doppler imaging received either bypass surgery or percutaneous transluminal balloon angioplasty (PTA). We present the 3 year limb salvage rate and angiographic disease patterns in 42 consecutive diabetic patients with CLI who received PTA in 2005. Methods and M...

  1. Deposition of In-111-labeled platelets after percutaneous transluminal angioplasty

    International Nuclear Information System (INIS)

    Platelet aggregation is presumed to occur at angioplasty sites after intimal disruption. This deposition may lead to acute thromboembolic events and is probably an initial event in recurring arteriosclerotic plaque formation. Thus far the author have studied this process in ten patients undergoing percutaneous transluminal angioplasty (PTA) by labeling the patient's platelets with In-111 on the day prior to PTA. The patient is imaged before the angioplasty procedure and 4 and 24 hours after the procedure. Platelet aggregation at the angioplasty site can be visualized and platelet volume quantified in all patients. The technique is being used in the evaluation of platelet aggregation after PTA. The author attempt to determine the frequency and volume of aggregation, correlate these findings with physical findings, assess the effect of platelet-inhibiting drugs, and assess the anatomic site of angioplasty in terms of predilection for platelet aggregation

  2. High plasma coenzyme Q10 concentration is correlated with good left ventricular performance after primary angioplasty in patients with acute myocardial infarction

    Science.gov (United States)

    Huang, Ching-Hui; Kuo, Chen-Ling; Huang, Ching-Shan; Tseng, Wan-Min; Lian, Ie Bin; Chang, Chia-Chu; Liu, Chin-San

    2016-01-01

    Abstract Exogenous administration of coenzyme Q10 (CoQ10) has been shown in experimental models to have a protective effect against ischemia–reperfusion injury. However, it is unclear whether follow-up plasma CoQ10 concentration is prognostic of left ventricular (LV) performance after primary balloon angioplasty in patients with acute ST segment elevation myocardial infarction (STEMI). We prospectively recruited 55 patients with STEMI who were treated with primary coronary balloon angioplasty. Plasma CoQ10 concentrations were measured before primary angioplasty (baseline) and 3 days, 7 days, and 1 month after STEMI using high-performance liquid chromatography. Echocardiography was performed at baseline and at 6-month follow-up. The control group comprised 54 healthy age- and sex-matched volunteers. Serial circulating CoQ10 concentrations significantly decreased with time in the STEMI group. The LV ejection fraction at 6-month follow-up positively correlated with the 1-month plasma CoQ10 tertile. Higher plasma CoQ10 concentrations at 1 month were associated with favorable LV remodeling and systolic function 6 months after STEMI. Multiple linear regression analysis showed that changes in CoQ10 concentrations at 1-month follow-up were predictive of LV systolic function 6 months after STEMI. Changes in CoQ10 concentrations correlated negatively with baseline oxidized low-density lipoprotein and fibrinogen concentrations and correlated positively with leukocyte mitochondrial copy number at baseline. Patients with STEMI who had higher plasma CoQ10 concentrations 1 month after primary angioplasty had better LV performance at 6-month follow-up. In addition, higher plasma CoQ10 concentration was associated with lower grade inflammatory and oxidative stress status. Therefore, plasma CoQ10 concentration may serve as a novel prognostic biomarker of LV systolic function after revascularization therapy for acute myocardial infarction. PMID:27495100

  3. Carotid angioplasty and stenting in the elderly

    International Nuclear Information System (INIS)

    To investigate the technical success rate as well as the procedural and mid-term complication rates of carotid angioplasty and stenting in elderly patients, a group excluded from large randomized endarterectomy trials given their perceived high surgical risk. Of 200 consecutive carotid angioplasty and/or stenting procedures performed between March 1996 and March 2005, 21 procedures were performed without cerebral protection devices in 20 patients over the age of 79 years (mean age: 83 years, 12 men, eight women). These patients' medical records were retrospectively reviewed for vascular imaging reports and available clinical follow-up. Procedural and mid-term complication rates were calculated and compared to a previously published cohort of 133 consecutive patients ≤79 years of age who also underwent endovascular treatment at our institution. Carotid stenosis was reduced from a mean of 82% to no significant stenosis in all procedures. The procedural stroke rate was zero of 21 procedures. The procedural transient ischemic attack rate (TIA) was one of 21 procedures (4.8%). Mean follow-up was 24.6 months (range: 1.0-79.5 months) with at least a 30-day follow-up for 20 of the 21 procedures (95.2%). There were no new strokes. There was one recurrent ipsilateral TIA at 1.9 months. In five cases with follow-up carotid ultrasonography, no hemodynamically significant restenosis had occurred. There were three myocardial infarctions (MI) occurring at 0.5, 2.1, and 15.2 months, of which the last MI was fatal. The composite 30-day stroke and death rate was zero of 21 procedures (95% confidence interval: 0-14%). No significant difference was found in the 30-day rate of stroke, TIA, MI, or death between the elderly and younger patients. Carotid angioplasty and stenting in elderly patients can be performed successfully with acceptable procedural and mid-term complication rates comparable to younger patients. (orig.)

  4. Primary Infrainguinal Subintimal Angioplasty in Diabetic Patients

    International Nuclear Information System (INIS)

    The aim of this study was to prospectively evaluate technical and clinical results of infrainguinal subintimal angioplasty in a series of diabetic patients with limb-threatening ischemia. From July 2003 to December 2007, 60 consecutive diabetic patients (M/F = 41/19; mean age, 69.4 ± 9.4 years) with Fontaine stage IV critical limb ischemia, not suitable for surgical recanalization, underwent primary infrainguinal subintimal angioplasty. The technical success, perioperative morbidity and mortality, and clinical success (defined by ulcer healing) were evaluated. Kaplan-Meier life-table analysis was obtained for cumulative clinical success, limb salvage, and survival rates. The procedure was technically successful in 55 of 60 (91.7%) patients; in 5 cases we were not able to achieve a reentry. Periprocedural mortality was 5% (3 patients); three patients (5%) required major amputation periprocedurally. Mean follow-up was 23 months (range, 0-48 months). On an intention-to-treat basis, the limb salvage rate was 93.3% (56/60 patients); ulcer healing was observed in 45 of 60 (75%) patients and it was significantly (p < 0.05) associated with serum creatinine and HbA1c levels, diabetes duration, and infrapopliteal recanalization. One- and three-year cumulative survival rates were 91.5% and 83.1%, respectively; serum creatinine levels, patient age, and clinical success were significant predictors of survival. In conclusion, infrainguinal primary subintimal angioplasty is a safe and effective treatment in diabetic patients with limb-threatening ischemia not suitable for surgical recanalization. This procedure is aimed to create a 'temporary bypass' that facilitates ulcer healing.

  5. Occult, massive hematomas following antegrade femoral angioplasty

    International Nuclear Information System (INIS)

    Small groin hematomas are not uncommon after percuatenous antegrade femoral angioplasty (PAFA) and are usually apparent clinically. The authors describe three patients of 235 who underwent PAFA, in whom occult, massive hemorrhage was detected after the procedure. All patients underwent fluoroscopically guided antegrade punctures, with adequate hemostasis achieved after the procedure. CT revealed extraperitoneal hematomas in two patients. One patient required surgical intervention with ligation of the inferior epigastric artery. The authors postulate that these hematomas arose due to inadvertent injury to a branch of the common femoral artery during the puncture. The radiologist should be aware of the chance occurrence of this occult, potentially life-threatening complication

  6. Re-stenosis and successful angioplasty

    International Nuclear Information System (INIS)

    Histologic analysis was undertaken on a sample of 20 perfusion-fixed arteries from NZW rabbits 1 month after angioplasty of focal femoral arteriosclerotic lesions. The samples chosen were representative of re-stenosis (>50% stenosis), good result, or aneurysm as defined angiographically. All good results but only half of the restenosis had histologic evidence of a tear into media or adventitia. Tears into adventitia were more likely to have a good result. New myointimal proliferation was more severe with restenosis. An arterial tear was necessary but not sufficient for a good result; outcome was ultimately dependent on the degree of intimal hyperplasia

  7. Prevention of Intracranial In-stent Restenoses: Predilatation with a Drug Eluting Balloon, Followed by the Deployment of a Self-Expanding Stent

    International Nuclear Information System (INIS)

    Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54–86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followed by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.

  8. Prevention of Intracranial In-stent Restenoses: Predilatation with a Drug Eluting Balloon, Followed by the Deployment of a Self-Expanding Stent

    Energy Technology Data Exchange (ETDEWEB)

    Vajda, Zsolt, E-mail: Z.Vajda@klinikum-stuttgart.de; Guethe, Thomas, E-mail: T.Guethe@klinikum-stuttgart.de; Perez, Marta Aguilar, E-mail: M.Aguilar@klinikum-stuttgart.de; Kurre, Wiebke, E-mail: w.kurre@klinikum-stuttgart.de [Klinikum Stuttgart, Katharinenhospital, Klinik fuer Neuroradiologie, Neurozentrum (Germany); Schmid, Elisabeth, E-mail: ESchmid@klinikum-stuttgart.de; Baezner, Hansjoerg, E-mail: H.Baezner@klinikum-stuttgart.de [Klinikum Stuttgart, Klinik fuer Neurologie, Neurozentrum (Germany); Henkes, Hans, E-mail: hhhenkes@aol.com [Klinikum Stuttgart, Katharinenhospital, Klinik fuer Neuroradiologie, Neurozentrum (Germany)

    2013-04-15

    Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54-86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followed by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.

  9. Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery

    International Nuclear Information System (INIS)

    Background: To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Methods: Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. Results: The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Conclusions: Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found

  10. Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Weber, W. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany); Mayer, T.E. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Henkes, H. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany); Kis, B. [Department of Neurology, Alfried Krupp Hospital, Essen (Germany) and Department of Psychiatry and Psychotherapy, University of Duisburg-Essen, Virchow Street 174, D-45147 Essen (Germany)]. E-mail: bernhard.kis@uni-duisburg-essen.de; Hamann, G.F. [Department of Neurology, Klinikum Grosshadern, University of Munich (Germany); Holtmannspoetter, M. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Brueckmann, H. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Kuehne, D. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany)

    2005-11-01

    Background: To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Methods: Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. Results: The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Conclusions: Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found.

  11. Effects of ilexonin a on IL-6 and M-CSF following ballon angioplasty in rabbit common carotid artery

    International Nuclear Information System (INIS)

    Objective: To observe the effects of ilexonin A(IA) on IL-6 and M-CSF following ballon angioplasty in rabbit common carotide artery to provide experimental basis for percutaneous coronary interventions. Mehtods: 30 Japanese rabbits were fed with high cholesterol food for 4 weeks. Then they were divided into three groups randomly. Each group had ten rabbits. 1) Control group: the incision was sew directly after right carotide artery of the rabbit was seeked. 2) Balloon dilation group: the proximal of the carotide artery was cuted, the ballon was delivered and distended, after it was drawn repeatly, the incision was closed. 3) IA therapy group: operation was the same to the balloon dilation group, then IA was administered in vein. All of them were fed with high cholesterol diet for 4 weeks and the blood samples were collected 1 d before the operation and 1 d, 1,2,4 weeks after the operation. The serum IL-6 and M-CSF levels were determined with radioimmunoassay. The pathological changes of injuried artery were observed. Results: 1) The IL-6 level in balloon dilation group was higher than that in IA therapy group after the operation (P<0.05), and came back later to preoperation level. 2) Though the M-CSF level in IA therapy group was increased, but it was lower than that in dilation group (P<0.05). 3) The pathological results demonstrated that the artery endothelial in control group was smooth and no foam cell in sight. In bolloon dilation group, the endangium was thickened, the vascular smooth muscle cells proliferated, there were many foam cells and the lumen was constrictive. In IA therapy group, the number of foam cells reduced, the constrictive degree of lumen was alleviated. Conclusion: IA can redece the levels of serum IL-6 and M-CSF and inhibit the proliferation of vascular smooth muscle cells following ballon angioplasty. (authors)

  12. Obesity and gastric balloon

    Directory of Open Access Journals (Sweden)

    Mohammed I Yasawy

    2014-01-01

    Full Text Available Background: The obesity epidemic, which is among the most common nutritional disorders, is rising rapidly worldwide. It leads to several health problems such as metabolic disorders, stroke, and even cancer. Efforts to control obesity with exercise and diet have a limited value in obese patients and different approaches to do this have been tried. In this paper, we share our experience with bioenteric intragastric balloon (BIB in treating obesity: Its safety, tolerability, and its efficacy in weight reduction. Materials and Methods: From January 2009 to September 2012, a total of 190 gastric balloons was inserted on patients at the endoscopy unit in King Fahd Hospital of the University, Al-Khobar. This is an evaluation of the first 100 patients. All the patients had a body mass index of over 30 kg/m 2 and were within the age range of 17-55 with a mean age of 32 years. After consent, preballoon investigation tests and anesthesia evaluation, BIB was inserted under monitored anesthesia care sedation in the endoscopy suite. The balloon was filled with 500-700 mls of stained saline. All patients′ were given an analgesic and antiemetic for a week and antisecretory proton pump inhibitor′s for 6 months. Diet and the importance of the exercise were part of the preballoon insertion phase and protocol. The balloon was removed after 6-12 months. Results: The weight loss response to BIB in the 100 patients are classified into four groups: In the uncooperative, noncompliant patients - the maximum weight loss was 7 kg, while in the most compliant patients the weight loss reached up to 39 kg. In addition, there was significant improvement into diabetes mellitus, hypertension, dyslipidemia, and fatty liveras. Its safety and tolerability were extremely acceptable. Conclusion: Our data indicates that in well-selected patients, BIB is an effective device, which with minimum complications helps to achieve body weight loss and resolve many obesity related

  13. Obesity and gastric balloon

    OpenAIRE

    Yasawy, Mohammed I; Al-Quorain, Abdulaziz A.; Anas M Hussameddin; Yasawy, Zakia M.; Al-Sulaiman, Raid M.

    2014-01-01

    Background: The obesity epidemic, which is among the most common nutritional disorders, is rising rapidly worldwide. It leads to several health problems such as metabolic disorders, stroke, and even cancer. Efforts to control obesity with exercise and diet have a limited value in obese patients and different approaches to do this have been tried. In this paper, we share our experience with bioenteric intragastric balloon (BIB) in treating obesity: Its safety, tolerability, and its efficacy in...

  14. Clad ballooning model in MELCOR

    International Nuclear Information System (INIS)

    Clad ballooning may substantially decrease the flow of fluids through the affected core region and may expose the inner cladding surface to oxidation in the vicinity of rupture sites. The cladding ballooning model was not included in MELCOR 1.8.4. and consideration of incorporating the cladding ballooning model is scheduled as a post-1.8.4 release activity. The purpose of this paper is to analyze the effect of the clad ballooning model by the modified MELCOR 1.8.4 with this model. The typical accident sequence of a large LOCA scenario is selected. The clad ballooning model accelerates the accident progression compared to that without the ballooning model. The amount of hydrogen does not change much and it may be caused by ignoring the effect of flow area change. Future study is planning to analyze the flow redistribution

  15. Magnetic Particle / Magnetic Resonance Imaging: In-Vitro MPI-Guided Real Time Catheter Tracking and 4D Angioplasty Using a Road Map and Blood Pool Tracer Approach.

    Directory of Open Access Journals (Sweden)

    Johannes Salamon

    Full Text Available In-vitro evaluation of the feasibility of 4D real time tracking of endovascular devices and stenosis treatment with a magnetic particle imaging (MPI / magnetic resonance imaging (MRI road map approach and an MPI-guided approach using a blood pool tracer.A guide wire and angioplasty-catheter were labeled with a thin layer of magnetic lacquer. For real time MPI a custom made software framework was developed. A stenotic vessel phantom filled with saline or superparamagnetic iron oxide nanoparticles (MM4 was equipped with bimodal fiducial markers for co-registration in preclinical 7T MRI and MPI. In-vitro angioplasty was performed inflating the balloon with saline or MM4. MPI data were acquired using a field of view of 37.3×37.3×18.6 mm3 and a frame rate of 46 volumes/sec. Analysis of the magnetic lacquer-marks on the devices were performed with electron microscopy, atomic absorption spectrometry and micro-computed tomography.Magnetic marks allowed for MPI/MRI guidance of interventional devices. Bimodal fiducial markers enable MPI/MRI image fusion for MRI based roadmapping. MRI roadmapping and the blood pool tracer approach facilitate MPI real time monitoring of in-vitro angioplasty. Successful angioplasty was verified with MPI and MRI. Magnetic marks consist of micrometer sized ferromagnetic plates mainly composed of iron and iron oxide.4D real time MP imaging, tracking and guiding of endovascular instruments and in-vitro angioplasty is feasible. In addition to an approach that requires a blood pool tracer, MRI based roadmapping might emerge as a promising tool for radiation free 4D MPI-guided interventions.

  16. Magnetic Particle / Magnetic Resonance Imaging: In-Vitro MPI-Guided Real Time Catheter Tracking and 4D Angioplasty Using a Road Map and Blood Pool Tracer Approach

    Science.gov (United States)

    Jung, Caroline; Kaul, Michael Gerhard; Werner, Franziska; Them, Kolja; Reimer, Rudolph; Nielsen, Peter; vom Scheidt, Annika; Adam, Gerhard; Knopp, Tobias; Ittrich, Harald

    2016-01-01

    Purpose In-vitro evaluation of the feasibility of 4D real time tracking of endovascular devices and stenosis treatment with a magnetic particle imaging (MPI) / magnetic resonance imaging (MRI) road map approach and an MPI-guided approach using a blood pool tracer. Materials and Methods A guide wire and angioplasty-catheter were labeled with a thin layer of magnetic lacquer. For real time MPI a custom made software framework was developed. A stenotic vessel phantom filled with saline or superparamagnetic iron oxide nanoparticles (MM4) was equipped with bimodal fiducial markers for co-registration in preclinical 7T MRI and MPI. In-vitro angioplasty was performed inflating the balloon with saline or MM4. MPI data were acquired using a field of view of 37.3×37.3×18.6 mm3 and a frame rate of 46 volumes/sec. Analysis of the magnetic lacquer-marks on the devices were performed with electron microscopy, atomic absorption spectrometry and micro-computed tomography. Results Magnetic marks allowed for MPI/MRI guidance of interventional devices. Bimodal fiducial markers enable MPI/MRI image fusion for MRI based roadmapping. MRI roadmapping and the blood pool tracer approach facilitate MPI real time monitoring of in-vitro angioplasty. Successful angioplasty was verified with MPI and MRI. Magnetic marks consist of micrometer sized ferromagnetic plates mainly composed of iron and iron oxide. Conclusions 4D real time MP imaging, tracking and guiding of endovascular instruments and in-vitro angioplasty is feasible. In addition to an approach that requires a blood pool tracer, MRI based roadmapping might emerge as a promising tool for radiation free 4D MPI-guided interventions. PMID:27249022

  17. Use of Rhenium-188 Liquid-Filled Balloons for Inhibition of Coronary Restenosis After PTCA - A New Opportunity for Nuclear Medicine

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, F.F., Jr.; Spencer, R.H.; Stabin, M.

    1999-05-13

    Although the use of ionizing radiation for the treatment of benign lesions such as keloids has been available for nearly one hundred years, only recently have the cost effective benefits of such technology for the inhibition of arterial restenosis following controlled vessel damage from balloon angioplasty been fully realized. In particular, the use of balloons filled with solutions of beta-emitting radioisotopes for vessel irradiation provide the benefit of uniform vessel irradiation. Use of such contained ("unsealed") sources is expected to represent a new opportunity for nuclear medicine physicians working in conjunction with interventional cardiologists to provide this new approach for restenosis therapy.

  18. Breakthrough in Mars balloon technology

    Science.gov (United States)

    Kerzhanovich, V. V.; Cutts, J. A.; Cooper, H. W.; Hall, J. L.; McDonald, B. A.; Pauken, M. T.; White, C. V.; Yavrouian, A. H.; Castano, A.; Cathey, H. M.; Fairbrother, D. A.; Smith, I. S.; Shreves, C. M.; Lachenmeier, T.; Rainwater, E.; Smith, M.

    2004-01-01

    Two prototypes of Mars superpressure balloons were flight tested for aerial deployment and inflation in the Earth's stratosphere in June, 2002. One was an 11.3 m diameter by 6.8 m high pumpkin balloon constructed from polyethylene film and Zylon (PBO) tendons, the second was a 10 m diameter spherical balloon constructed from 12 μm thick Mylar film. Aerial deployment and inflation occurred under parachute descent at 34 km altitude, mimicing the dynamic pressure environment expected during an actual Mars balloon mission. Two on-board video cameras were used on each flight to provide real-time upward and downward views of the flight train. Atmospheric pressure and temperature were also recorded. Both prototypes successfully deployed from their storage container during parachute descent at approximately 40 m/s. The pumpkin balloon also successfully inflated with a 440 g charge of helium gas injected over a 1.5-min period. Since the helium inflation system was deliberately retained after inflation in this test, the pumpkin balloon continued to fall to the ocean where it was recovered for post-flight analysis. The less robust spherical balloon achieved only a partial (~70%) inflation before a structural failure occurred in the balloon film resulting in the loss of the vehicle. This structural failure was diagnosed to result from the vigorous oscillatory motion of the partially inflated balloon, possibly compounded by contact between the balloon film and an instrumentation box above it on the flight train. These two flights together represent significant progress in the development of Mars superpressure balloon technology and pave the way for future flight tests that will include post-deployment flight of the prototype balloons at a stable altitude.

  19. Application of new balloon catheters in the treatment of congenital heart defects

    Science.gov (United States)

    Fiszer, Roland; Szkutnik, Małgorzata; Smerdziński, Sebastian; Chodór, Beata; Białkowski, Jacek

    2016-01-01

    Introduction Balloon angioplasty (BAP) and aortic or pulmonary balloon valvuloplasty (BAV, BPV) are well-established treatment options in congenital heart defects. Recently, significant technological progress has been made and new catheters have been implemented in clinical practice. Aim To analyze the results of BAP, BAV and BPV with the new balloon catheter Valver and its second generation Valver II, which the company Balton (Poland) launched and developed. These catheters have not been clinically evaluated yet. Material and methods We performed 64 interventions with Valver I and Valver II. With Valver I the following procedures were performed: 17 BPV (including 9 in tetralogy of Fallot – TOF), 10 BAV and 27 BAP in coarctations of the aorta (CoA) – including 9 native and 18 after surgery. With Valver II ten interventions were done – 3 BPV, 2 pulmonary supravalvular BAP (after switch operations), 2 BAP of recoarctations and 3 other BAP. Age of the patients ranged from a few days to 40 years. Results All procedures were completed successfully, without rupture of any balloon catheters. The pressure gradient drop was statistically significant in all groups: BPV in isolated pulmonary valvular stenosis 28.1 mm Hg (mean), BPV in TOF 18.7 mm Hg, BAV 32.8 mm Hg, BAP in native CoA 15.4 mm Hg and in recoarctations 18.6 mm Hg. In 3 cases during rapid deflation of Valver I, wrinkles of the balloons made it impossible to insert the whole balloon into the vascular sheath (all were removed surgically from the groin). No such complication occured with Valver II. Conclusions Valver balloon catheters are an effective treatment modality in different valvular and vascular stenoses. PMID:27625686

  20. Titan Balloon Convection Model Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This innovative research effort is directed at determining, quantitatively, the convective heat transfer coefficients applicable to a Montgolfiere balloon operating...

  1. Percutaneous transluminal angioplasty of chronic arterial occlusive disease below the knee joint

    International Nuclear Information System (INIS)

    The purpose of this study was to determine the safety and efficacy of the percutaneous transluminal angioplasty(PTA) in patients with chronic arterial occlusive disease below the knee joint. We retrospectively analyzed the results of 36 procedures in 16 patients. There were 15 men and one woman, aged 57-75 years(mean, 62 years). Indications were disabling claudication (SVS/ISCVS grade 1, category 3) in five cases, rest pain(grade 2, category 4) in three cases, and non-healing ulceration or gangrene(grade3, category 5) in eight cases. PTA was performed by using small vessel balloon catheter of 2-4 mm and 3 mm monorail balloon catheter in tibioperoneal vessels and 5-6 mm balloon catheter in distal popliteal artery and tibioperoneal trunk. Combined thrombolytic therapy with Urokinase was performed in 14 patients. Involved infrapopliteal vessels were four distal popliteal arteries, 15 tibioperoneal trunks, six anterior tibial arteries, five posterior tibial arteries, and seven peroneal arteries. Technical success was determined when post-PTA angiogram showed less than 30% of residual stenosis. Clinical success was defined as improvement of clinical symptoms, such as disappearance of claudication or rest pain, and healing of ulcereation. Technical success was achieved in 30 of 36 arteries(83%). Clinical success was achieved in 12 of 16 patients(75%) at an average follow-up of 13.3 months(range, 2-46 months). Clinical success rate was 100% in grade 1 category 3 patients, 67% in grade 2 category 4 patients, and 63% in grade 3 category 5 patients. Complication included two distal emboli, one vessel rupture, one vessel thrombosis, and one occluding intimal flap. PTA was an effective method for treatment of chronic arterial occlusive disease below the knee joint and considered as the procedure of first choice. Severe claudicant(grade1) should be included in the indication of the tibioperoneal PTA

  2. Treatment of pacemaker-induced superior vena cava syndrome by balloon angioplasty and stenting.

    LENUS (Irish Health Repository)

    Klop, B

    2011-01-01

    Superior vena cava (SVC) syndrome is a rare but serious complication after pacemaker implantation. This report describes three cases of SVC syndrome treated with venoplasty and venous stenting, with an average follow-up of 30.7 (±3.1) months. These cases illustrate that the definitive diagnosis, and the extent and location of venous obstruction, can only be determined by venography.

  3. Balloon Angioplasty and Drug Eluting Stenting for Treatment of Peripheral Arterial Occlusive Disease

    Directory of Open Access Journals (Sweden)

    Akın İzgi

    2010-08-01

    Full Text Available Peripheral arterial disease is one of the manifestations of systemic atherosclerosis. In the last decade, remarkable technological advances, especially in the stent area, have shifted revascularization strategies from traditional open surgical approaches toward less morbide percutaneous endovascular treatments. However, even with new designed nitinol bare stents, restenosis remains as the major obstacle of this procedures. More recently, drug eluting stent platforms have been used to treat atherosclerotic peripheral arterial disease. In this article, we reviewed new studies relevant to drug eluting stents for lower extremity peripheral arterial occlusive disease.

  4. Clopidogrel Responsiveness in Patients Undergoing Peripheral Angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Pastromas, Georgios, E-mail: geopastromas@gmail.com; Spiliopoulos, Stavros, E-mail: stavspiliop@upatras.gr; Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Diamantopoulos, Athanasios, E-mail: adiamantopoulos@gmail.com; Kitrou, Panagiotis, E-mail: panoskitrou@gmail.com; Karnabatidis, Dimitrios, E-mail: karnaby@med.upatras.gr; Siablis, Dimitrios, E-mail: siablis@med.upatras.gr [Patras University Hospital, Department of Interventional Radiology (Greece)

    2013-12-15

    Purpose: To investigate the incidence and clinical significance of platelet responsiveness in patients receiving clopidogrel after peripheral angioplasty procedures. Materials and Methods: This prospective study included patients receiving antiplatelet therapy with clopidogrel 75 mg after infrainguinal angioplasty or stenting and who presented to our department during routine follow-up. Clopidogrel responsiveness was tested using the VerifyNow P2Y12 Assay. Patients with residual platelet reactivity units (PRU) {>=} 235 were considered as nonresponders (NR group NR), whereas patients with PRU < 235 were considered as normal (responders [group R]). Primary end points were incidence of resistance to clopidogrel and target limb reintervention (TLR)-free survival, whereas secondary end points included limb salvage rates and the identification of any independent predictors influencing clinical outcomes. Results: In total, 113 consecutive patients (mean age 69 {+-} 8 years) with 139 limbs were enrolled. After clopidogrel responsiveness analysis, 61 patients (53.9 %) with 73 limbs (52.5 %) were assigned to group R and 52 patients (46.1 %) with 66 limbs (47.5 %) to group NR. Mean follow-up interval was 27.7 {+-} 22.9 months (range 3-95). Diabetes mellitus, critical limb ischemia, and renal disease were associated with clopidogrel resistance (Fisher's exact test; p < 0.05). According to Kaplan-Meier analysis, TLR-free survival was significantly superior in group R compared with group NR (20.7 vs. 1.9 %, respectively, at 7-year follow-up; p = 0.001), whereas resistance to clopidogrel was identified as the only independent predictor of decreased TLR-free survival (hazard rate 0.536, 95 % confidence interval 0.31-0.90; p = 0.01). Cumulative TLR rate was significantly increased in group NR compared with group R (71.2 % [52 of 73] vs. 31.8 % [21 of 66], respectively; p < 0.001). Limb salvage was similar in both groups. Conclusion: Clopidogrel resistance was related with

  5. Clopidogrel Responsiveness in Patients Undergoing Peripheral Angioplasty

    International Nuclear Information System (INIS)

    Purpose: To investigate the incidence and clinical significance of platelet responsiveness in patients receiving clopidogrel after peripheral angioplasty procedures. Materials and Methods: This prospective study included patients receiving antiplatelet therapy with clopidogrel 75 mg after infrainguinal angioplasty or stenting and who presented to our department during routine follow-up. Clopidogrel responsiveness was tested using the VerifyNow P2Y12 Assay. Patients with residual platelet reactivity units (PRU) ≥ 235 were considered as nonresponders (NR group NR), whereas patients with PRU < 235 were considered as normal (responders [group R]). Primary end points were incidence of resistance to clopidogrel and target limb reintervention (TLR)-free survival, whereas secondary end points included limb salvage rates and the identification of any independent predictors influencing clinical outcomes. Results: In total, 113 consecutive patients (mean age 69 ± 8 years) with 139 limbs were enrolled. After clopidogrel responsiveness analysis, 61 patients (53.9 %) with 73 limbs (52.5 %) were assigned to group R and 52 patients (46.1 %) with 66 limbs (47.5 %) to group NR. Mean follow-up interval was 27.7 ± 22.9 months (range 3–95). Diabetes mellitus, critical limb ischemia, and renal disease were associated with clopidogrel resistance (Fisher’s exact test; p < 0.05). According to Kaplan–Meier analysis, TLR-free survival was significantly superior in group R compared with group NR (20.7 vs. 1.9 %, respectively, at 7-year follow-up; p = 0.001), whereas resistance to clopidogrel was identified as the only independent predictor of decreased TLR-free survival (hazard rate 0.536, 95 % confidence interval 0.31–0.90; p = 0.01). Cumulative TLR rate was significantly increased in group NR compared with group R (71.2 % [52 of 73] vs. 31.8 % [21 of 66], respectively; p < 0.001). Limb salvage was similar in both groups. Conclusion: Clopidogrel resistance was related with

  6. Nationwide Eclipse Ballooning Project

    Science.gov (United States)

    Colman Des Jardins, Angela; Berk Knighton, W.; Larimer, Randal; Mayer-Gawlik, Shane; Fowler, Jennifer; Harmon, Christina; Koehler, Christopher; Guzik, Gregory; Flaten, James; Nolby, Caitlin; Granger, Douglas; Stewart, Michael

    2016-05-01

    The purpose of the Nationwide Eclipse Ballooning Project is to make the most of the 2017 rare eclipse event in four main areas: public engagement, workforce development, partnership development, and science. The Project is focused on two efforts, both student-led: online live video of the eclipse from the edge of space and the study of the atmospheric response to the eclipse. These efforts, however, involving more than 60 teams across the US, are challenging in many ways. Therefore, the Project is leveraging the NASA Space Grant and NOAA atmospheric science communities to make it a success. The first and primary topic of this poster is the NASA Space Grant supported online live video effort. College and high school students on 48 teams from 31 states will conduct high altitude balloon flights from 15-20 locations across the 8/21/2017 total eclipse path, sending live video and images from near space to a national website. Video and images of a total solar eclipse from near space are fascinating and rare. It’s never been done live and certainly not in a network of coverage across a continent. In addition to the live video to the web, these teams are engaged in several other science experiments as secondary payloads. We also briefly highlight the eclipse atmospheric science effort, where about a dozen teams will launch over one hundred radiosondes from across the 2017 path, recording an unprecedented atmospheric data sample. Collected data will include temperature, density, wind, humidity, and ozone measurements.

  7. Percutaneous transluminal angioplasty after vascular surgery

    International Nuclear Information System (INIS)

    Percutaneous transluminal angioplasty (PTA) was used to treat 32 patients with 80%-95% stenoses in vascular bypass grafts and anastomotic stenoses. Eight lesions were in femoropopliteal, three in femorotibial, and one in femorofemoral crossover grafts. Twenty patients had stenoses at the prosimal or distal graft anastomoses. PTA was successful and enabled surgical intervention to be avoided in 29 of the 32 patients. Postdilation angiography demonstrated a substantial increase in luminal diameter and Doppler ankle-arm indexes were improved in all 29 successful cases. Long-term follow-up was available in 26 patients. After an average of 15 months, the graft was occluded in nine (35%) of the 26. In the other 17 patients (65%), the graft remained patent. The dilation of graft stenoses may be controversial and is difficult due to the diversity of underlying causes, such as intimal thickening, fibrotic reaction, and suture scar. The author's experience indicates that PTA is an efficient and safe treatment

  8. Intracoronary radionuclide therapy with liquid 188Re-filled balloons; radiopharmaceutical and dosimetric studies

    International Nuclear Information System (INIS)

    Percutaneous transluminal coronary angioplasty associated with radioactive liquid-filled balloons has demonstrated to be useful to inhibit the growth of neo intimal tissue. The present study pursued optimizing the relation risk/benefit during a procedure of brachytherapy with 188Re associated to angioplasty. Since the possibility of balloon rupture exists, to increase the security during the treatment different agents such as 188Re-DTPA, 188Re-Citrate and 188Re-EC vs 188ReO4 were evaluated. Dosimetric studies using Mirdose 3, after iv injection to Wistar rats, evaluation of a number of safety requirements in order to estimate radiation dose delivered to operating personnel and absorbed doses estimated by Monte Carlo method (PENELOPE). It is a safe procedure, both for the patient and the working staff; in case of ballon rupture the use of the above mentioned radiopharmaceuticals increases its security. 188Reβ emitor achieves a local dosis, diminishing the dose in healthy tissue (au)

  9. Excimer laser coronary angioplasty: experience with a prototype multifibre catheter in patients with stable angina pectoris.

    Science.gov (United States)

    Kochs, M; Haerer, W; Eggeling, T; Hoeher, M; Schmidt, A; Hombach, V

    1992-03-01

    Percutaneous excimer laser coronary angioplasty (ELCA) was performed in a first group of 20 patients with stable angina pectoris caused by significant coronary stenosis, and long-term follow-up was evaluated. Prototype 4 to 5.5 French multifibre catheters with 18-20 quartz fibres of 100 microns diameter, concentrically arranged around a central lumen for taking up a guide wire, were coupled to a commercial XeCl excimer laser. Energy was delivered at a wavelength of 308 nm with a pulse duration of 60 or 120 ns. Operating at a repetition rate of 20 Hz, mean energy transmission was 13.4 +/- 6.8 mJ per pulse. In all but one patient the lesion could be passed by the catheter. Percent diameter stenosis decreased from 77.1 +/- 10.8% to 53.1 +/- 11.8% after ELCA. Complications were frequently observed, intracoronary thrombus formation in eight instances, dissection in six patients and spasm in five cases, causing total vessel occlusion in five procedures. All complications could be managed efficaciously by thrombolytic and vasodilating drugs and/or balloon angioplasty. Subsequent PTCA was performed in case of complication or insufficient stenosis reduction after ELCA in 18 patients with adequate results (residual stenosis, 28.5 +/- 10.2%). Long-term follow-up angiography, which could be performed in 16 of 19 laser treatments, demonstrated significant restenosis in only three patients. Our preliminary results suggest that, using ELCA, ablation of atherosclerotic lesions is feasible in most cases. However, compared with PTCA, stenosis reduction is significantly less, and the acute complication rate is much higher. Thus, further improvements of the catheter system are necessary in order to realize the advantages of excimer laser ablation, which can be demonstrated by experimental studies. PMID:1597220

  10. Angioplasty of forearm arteries as a finger salvage procedure for patient with end-stage renal failure.

    Science.gov (United States)

    Law, Yuk; Chan, Yiu Che; Cheng, Stephen Wing-Keung

    2016-01-01

    Due to the relatively low metabolic demand and extensive collaterals of the upper limb, peripheral arterial disease seldom leads to tissue loss, except in patients with end-stage renal failure (ESRF), rheumatologic diseases, Raynaud's disease, frostbites, or distal emboli. We report a case of a 51-year-old lady with ESRF who presented to our tertiary referral vascular center with infected gangrene of her right ring finger. Duplex ultrasound showed that her forearm arteries were severely diseased. Digital subtraction angiogram showed severe multilevel stenoses/occlusions in her forearm radial and ulnar arteries. These lesions were successfully angioplastized with 2 mm × 25 mm angioplasty balloon. Completion angiogram showed good radiological results with some post-dilatation spasm which improved with intra-arterial glyceryl trinitrate. The sepsis improved after revascularization, and the distal phalanx was allowed to self-demarcate with dressings and autoamputate with good clinical results. Our case illustrated that even in delayed setting, patients could still benefit from specialist vascular care with a combination of expert care and angioplasty of forearm arteries, with successful salvage of her finger. PMID:27143949

  11. Angioplasty of forearm arteries as a finger salvage procedure for patient with end-stage renal failure

    Science.gov (United States)

    Law, Yuk; Chan, Yiu Che; Cheng, Stephen Wing-Keung

    2016-01-01

    Due to the relatively low metabolic demand and extensive collaterals of the upper limb, peripheral arterial disease seldom leads to tissue loss, except in patients with end-stage renal failure (ESRF), rheumatologic diseases, Raynaud’s disease, frostbites, or distal emboli. We report a case of a 51-year-old lady with ESRF who presented to our tertiary referral vascular center with infected gangrene of her right ring finger. Duplex ultrasound showed that her forearm arteries were severely diseased. Digital subtraction angiogram showed severe multilevel stenoses/occlusions in her forearm radial and ulnar arteries. These lesions were successfully angioplastized with 2 mm × 25 mm angioplasty balloon. Completion angiogram showed good radiological results with some post-dilatation spasm which improved with intra-arterial glyceryl trinitrate. The sepsis improved after revascularization, and the distal phalanx was allowed to self-demarcate with dressings and autoamputate with good clinical results. Our case illustrated that even in delayed setting, patients could still benefit from specialist vascular care with a combination of expert care and angioplasty of forearm arteries, with successful salvage of her finger. PMID:27143949

  12. Percutaneous Transluminal Angioplasty of Hepatic Artery Stenosis in Patients After Orthotopic Liver Transplantation: Mid-term Results

    International Nuclear Information System (INIS)

    Purpose: This study was designed to present our experience with percutaneous treatment of hepatic artery stenosis in orthotopic liver transplant patients and to evaluate the efficacy, technical outcomes, and mid-term clinical results of the procedure. Methods: Twenty-two percutaneous transluminal angioplasties (PTAs) were performed in 19 liver transplant recipients at our institution between 1998 and 2010. Stents were placed into the hepatic/celiac artery in 16 PTAs, but balloon dilatation alone was performed in 6 because of the anatomical condition of the vessel. PTA/stenting was indicated in 17 patients because of elevated liver enzymes; 2 patients were asymptomatic. The objective of treating stenosis was prevention of long-term complications, including thrombosis. Results: Technical success was achieved in all patients. There was only one complication: dissection of the treated artery without any subsequent adverse effects. In all patients, elevated liver enzyme levels improved after treatment. No restenosis was observed in any patient during a mean follow-up of 2.6 years (1 month to 5.5 years). Conclusions: Percutaneous angioplasty/stent placement is a safe method for the treatment of hepatic artery stenosis after orthotopic liver transplantation, with a high technical success rate and promising mid-term results.

  13. US Air Force Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Worksheets containing pilot balloon data computed from releases at Air Force stations in the western United States. Elevation and azimuth angles are used to compute...

  14. [Balloon valvuloplasty in stenotic bioprosthesis].

    Science.gov (United States)

    Astudillo, R; Farell, J; Ariza, H; González Carmona, V M; Abundes, A; Tello, R; López Cuellar, M

    1992-01-01

    The results of balloon valvuloplasty performed on five patients with stenotic bioprosthesis treated in the Hospital de Cardiología Centro Médico Nacional Siglo XXI, are presented. All five bioprosthesis were right sided, two in tricuspid position, one in pulmonary valve position and two in valvulated conduits from right ventricle to pulmonary artery. In all cases a pressure gradient reduction was achieved, an improvement of clinical functional class and heart failure manifestations were obtained. Mansfields balloons were used. One in two patients, and two balloons in three. We had not complications with the procedure. We conclude that balloon valvuloplasty on bioprosthesis is a safe and dependable procedure to be used in right sided bioprosthesis. PMID:1482221

  15. Superpressure Tow Balloon for Extending Durations and Modifying Trajectories of High Altitude Balloon Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation involves the concept of using a Superpressure Tow Balloon (STB) with existing NASA high altitude balloon designs to form a tandem balloon...

  16. Simple balloon dilation for drug-eluting in-stent restenosis: An optical coherent tomography analysis

    Energy Technology Data Exchange (ETDEWEB)

    Arikawa, Ryo [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Yamaguchi, Hiroshi, E-mail: hyamaguchi@tsm.bbiq.jp [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Takaoka, Junichiro; Miyamura, Akihiro; Atsuchi, Nobuhiko; Ninomiya, Toshiko; Atsuchi, Yoshihiko [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Ohishi, Mitsuru [Department of Cardiovascular Medicine and Hypertension, Graduate School of Medical and Dental Science, Kagoshima University, Kagoshima (Japan); Terashima, Mitsuyasu [Department of Cardiology, Toyohashi Heart Center, Toyohashi (Japan); Kaneda, Hideaki [Okinaka Memorial Institute for Medical Research, Tokyo (Japan)

    2015-01-15

    Background: Although drug-eluting stent (DES) has significantly reduced restenosis, the treatment of DES-in-stent restenosis (ISR) remains a challenge with high restenosis rate. Methods: We examined whether morphologic appearance of restenosis tissue by optical coherent tomography (OCT) had an impact on outcomes after balloon angioplasty for DES-ISR. The morphologic appearance of restenosis tissue was qualitatively assessed for tissue structures such as homogeneous, layered, and heterogeneous patterns. Results: Using OCT, 50 patients with DES-ISR were divided into 2 groups: 25 lesions with homogeneous or layered patterns (homo/layered group) and 25 lesions with heterogeneous patterns (hetero group). Acute gain was larger in the hetero group (1.33 ± 0.41 mm vs. 1.06 ± 0.32 mm in the homo/layered group, P = 0.03). On intravascular ultrasound analysis, post-procedural percent neointimal area was smaller in the hetero group (27.4 ± 9.2% vs. 34.0 ± 11.2% in the homo/layered group, P = 0.05). Angiographic follow-up was performed in 37 lesions (74%). Follow-up minimal lumen diameter was larger in the hetero group (1.75 ± 0.89 mm vs. 1.01 ± 0.81 mm in the homo/layered group, P = 0.04). Target lesion revascularization rates tended to be lower in the hetero group (20% vs. 43% in the homo/layered group, P = 0.12). Conclusions: Balloon angioplasty was more effective for DES-ISR with heterogeneous tissue appearance than DES-ISR with homogeneous/layered tissue appearance. OCT assessment of DES-ISR morphology may be a useful adjunct in determining clinical strategies. Simple balloon dilatation is a possible treatment strategy for DES-ISR lesions with a heterogeneous appearance on OCT images.

  17. Endovascular brachytherapy to prevent restenosis after angioplasty

    International Nuclear Information System (INIS)

    Endovascular radiotherapy is the first effective prophylaxis of restenosis after percutaneous transluminal angioplasty (PTA) and stenting. The FDA recently approved two devices for the delivery of intracoronary radiation following coronary artery stenting. Published multicenter, double-blind, randomized trials of intracoronary radiation therapy report good results for preventing in-stent restenosis, while the data for the peripheral circulation are still inconclusive. Beta-emitters are easier applicable and probably also safer, whereas gamma-emitters have been more extensively evaluated clinically so far. Primary indication for endovascular brachytherapy are patients at high risk for restenosis, such as previous restenoses, in-stent hyperplasia, long stented segment, long PTA lesion, narrow residual vascular lumen and diabetes. Data from coronary circulation suggest a safety margin of at least 4 to 10 mm at both ends of the angioplastic segment to avoid edge restenosis. To prevent late thrombosis of the treated coronary segment, antiplatelet therapy with clopidogrel and aspirin are recommended for at least 6 months after PTA and for 12 months after a newly implanted stent. An established medication regimen after radiotherapy of peripheral arteries is still lacking. (orig.)

  18. Mechanical and acoustic analysis in ultrasonic angioplasty

    Science.gov (United States)

    Detwiler, Paul W.; Watkins, James F.; Rose, Eric A.; Ratner, A.; Vu, Louis P.; Severinsky, J. Y.; Rosenschein, Uri

    1991-05-01

    The goal of this study was to investigate the relationship between ultrasonic tissue ablation and passive mechanical elasticity. Experience with ultrasonic angioplasty in experimental settings (in-vivo and in-vitro) together with clinical experience in peripheral vascular disease is reported. A model composed exclusively of a hydroxyproline ballistic gelatin matrix showed a negative correlation between material elasticity and the rate of ultrasonic ablation. This model provided a means of studying the effects of collagen content on ablation, exclusive of other biologic components. Ballistic gelatin ablation (mg/sec) was found to increase logarithmically with decreasing protein concentration over the range studied (20.00 to 1.25%). Ablation as a function of gelatin elasticity behaved in a similar manner. Temperature of the material ablated was also demonstrated to affect the rate of ablation. We conclude that the previously reported differences in ablation between thrombi and blood vessel are predictable based on the large difference in their mechanical elasticity, and that this difference provides a wide margin of safety.

  19. Astro research fellowship: low dose radiation to prevent restenosis after angioplasty

    International Nuclear Information System (INIS)

    Purpose: To determine the optimal time to deliver a single dose of external radiation therapy (12 Gy) postoperatively following balloon angioplasty (on same day, day 2 or day 4) to prevent restenosis in a non-stented swine model. To model an endovascular radioactive source for prevention of restenosis in the same animal model. Materials and Methods: Both external iliac arteries in eleven red duroc swine were injured using balloon overdilation (3 inflations, 60 secs. each, 16 psi), and the first five were additionally injured using denudation. One artery in each animal was then irradiated using anteroposterior and posterioranterior fields using Co-60 with 12 Gy prescribed to the midplane, with the other artery serving as a control. Irradiation was delivered on the same day, day 2 or day 4. Animals were sacrificed 3 months following injury, and histomorphometric analysis was performed. Additionally, a prototype endovascular beta source was designed and manufactured for clinical testing, based on Monte Carlo estimations. Results: Neointima formation was noted in both radiated and control arteries. The mean neointimal thickness in the radiated and control arteries was 116 ± 39 μm and 131 ± 47 μm respectively. Time of radiation delivery did not have a significant effect in preventing restenosis. Physical measurements of the endovascular source are in progress using a water based phantom. Animal testing will commence on ten red duroc swine. Conclusion: External radiation at this low dose does not appear to prevent restenosis in an unstented animal model. We hope to begin animal experiments using an endovascular source to prevent restenosis

  20. Endovascular brachytherapy (EVBT) with rhenium-188 for restenosis prophylaxis after angioplasty of infrainguinal lesions. Early experience

    International Nuclear Information System (INIS)

    Purpose: Restenosis remains a major problem in percutaneous transluminal angioplasty (PTA) of peripheral arteries. The aim of this feasibility study was to evaluate the technical feasibility and safety of a new endovascular brachytherapy (EVBT) device with Rhenium-188 in restenosis prophylaxis of infrainguinal arteries. Materials and Methods: From March 2006 to April 2009, 52 patients with 71 infrainguinal arterial lesions were treated with Re-188 to prevent restenosis after PTA. 40 patients with 53 lesions (24 de-novo lesions and 29 restenoses) were reexamined (clinic, color-coded duplex ultrasound) after a mean follow-up period of 12.7 months (2.6 to 25.1 months). The liquid beta-emitter Re-188 was introduced to the target lesion via an EVBT certified PTA balloon and a tungsten applicator. After the calculated irradiation time, Re-188 was aspirated back into the tungsten applicator. A dose of 13 Gy was applied at a depth of 2 mm into the vessel wall. Results: After a mean follow-up of 12.7 months, the overall restenosis rate after Re-PTA was 15.1 % (8/53 lesions). The restenosis rate for de-novo lesions was 20.8 % (5/24) and 10.3 % for restenoses (3/29). In 4 patients reintervention was necessary (3 PTAs and 2 major amputations). No periprocedural complications were observed. No elevated radiation dose for the patient or the interventionalist was measured. Conclusion: EVBT with a Re-188 filled balloon catheter was technically feasible and safe after PTA of infrainguinal arterial lesions with restenosis rates lower than expected compared to published results. Treatment of restenoses seems to be more effective than de-novo lesions. (orig.)

  1. Drug-Coated Balloon Venoplasty for In-Stent Restenosis in a Patient With Recurrent Pulmonary Vein Stenosis Post Ablation for Atrial Fibrillation: Initial Experience With a New Treatment Technique.

    Science.gov (United States)

    Rosenberg, Jonathan; Fisher, Westby G; Guerrero, Mayra; Smart, Steve; Levisay, Justin; Feldman, Ted; Salinger, Michael

    2016-05-01

    Pulmonary vein stenosis (PVS) is an uncommon but serious complication following radiofrequency ablation for atrial fibrillation. Occurrence of this complication has risen with increased rates of ablation procedures, with >50,000 AF ablation procedures performed per year, and can occur within weeks to months post procedure. Currently, the main therapies for PVS include percutaneous interventions with balloon angioplasty and stenting, but these treatments are complicated by a high rate of restenosis. The optimal treatment for recurrent pulmonary vein in-stent restenosis has not been determined. We describe the novel use of a paclitaxel drug-coated balloon for the treatment of in-stent restenosis of the pulmonary veins. PMID:27145055

  2. [Ultrasound coronary angioplasty: state of the art and new clinical aspects].

    Science.gov (United States)

    Rosenschein, U; Budde-Schwartzman, B

    1997-12-01

    stable angina or AMI were treated by ultrasound angioplasty. Residual stenosis after ultrasound treatment was 71%, after balloon dilation reduced to 34%. In the 6-month follow-up angiograms showed no major adverse effect or restenosis. Our experience with coronary ultrasound thrombolysis (CUT) is based on the analysis of 33 patients' data in the feasibility (Table 1) plus multicenter phase of the ACUTE trial (Analysis of Coronary Ultrasound Thrombolysis Endpoints) (Figure 3). Our patients were exclusively treated for AMI by ultrasound angioplasty and afterwards by PTCA if required (Figure 4). The average final percent stenosis was 20% (Figure 5). The main efficacy parameters, device success and angiographic success rates were 100%, clinical success rate was 91.7% (Figure 6 and Table 2). The adverse clinical events of CUT are limited--at least in our studies--to reocclusion of infarct-related artery and ischemia and could be reversed by additional PTCA. No adverse clinical side effects were observed during sonication of the coronary tree. Final angiography revealed residual stenosis of 20% without morphological signs. These excellent results suggest that bioselectivity of ultrasound together with the developed skills of the catheter system induces rapid and selective thrombolysis with no need to cross the target lesion before sonication. But what is the better solution for thrombosis and which for plaque disruption? The development of transluminal balloon catheter really modified therapeutic approach to obstructive coronary and peripheral arterial disease but it is still accompanied by a high rate of abrupt closure, AMI and death. Although the use of intravenous thrombolytic agents is well established in the treatment of AMI and these agents are widely used, a large patient collective remains (up to 33% and more) in whom their use is inadvisable due to recent stroke, surgery, trauma or other contraindications. (ABSTRACT TRUNCATED) PMID:9483436

  3. Percutaneous transluminal ultrasonic angioplasty: preliminary clinical report of ultrasound plaque ablation in totally occluded peripheral arteries.

    Science.gov (United States)

    Monteverde-Grether, C; Valez y Tello de Meneses, M; Nava-López, G; Jauregui, R; Borges, J; Abundes, A; López-Cuéllar, M; Armilla, M

    1991-01-01

    Peripheral arterial obstructive disease has been treated with ultrasound ablation. Thirty two patients (pts), mean age 67 +/- 10 years underwent angiosonoplasty, with a prototype ultrasonic system, due to severe claudication (31%), rest pain (44%), rest pain and ulceration (25%). Angiosonoplasty was successful in 26/32 (81%) stenoses, (1/2 iliac, 9/2 femorals, 11/12 popliteal, 5/6 tibial). Angiography before and after angiosonoplasty confirmed that the lesions were successfully opened, (81%, p less than 0.05). A mean of 3 +/- 2 passes were required to adequately remove sufficient plaque. Balloon angioplasty was used in combination with angiosonoplasty in 11/32 (34%) occluded vessels. Complications included groin hematoma in 4 pts (12%) and vascular spasm in two patients (6%). Within 24 hours, 27/32 (94%) pts were discharged clinically improved. Reocclusion occurred in 4 pts (12%) immediately after the procedure. Ankle brachial indices significantly increased from 0.52 +/- 0.10 before to 0.70 +/- 0.12 after (p less than 0.05). In conclusion, the use of ultrasound energy to ablate atherosclerotic plaque would appear safe, and has shown no restenosis and a low incidence of complications over a six month period. PMID:1840288

  4. [Reperfusion therapy in acute myocardial infarction: primary percutaneous transluminal coronary angioplasty or thrombolysis?].

    Science.gov (United States)

    Bilkis, Valdas; Kibarskis, Aleksandras; Abraitis, Vytautas

    2004-01-01

    Randomized controlled trials that compared primary percutaneous transluminal coronary angioplasty with thrombolysis have shown that primary angioplasty is more effective than intravenous thrombolysis in reducing mortality and morbidity in patients with acute myocardial infarction. Three large myocardial infarction registries - MITI, NRMI-2 and French registry - failed to show an advantage of primary angioplasty compared with thrombolysis. One of the latest trials mentioned in this paper restored the place of primary angioplasty as superior to thrombolysis in acute myocardial infarction. Data of patients treated with primary percutaneous transluminal coronary angioplasty in Clinic of Cardiology of Vilnius University are presented. PMID:15079110

  5. The case for angioplasty in patients with symptomatic intracranial atherosclerosis.

    Science.gov (United States)

    McTaggart, Ryan A; Marks, Michael P

    2014-01-01

    Intracranial atherosclerotic disease (ICAD) is likely the most common cause of stroke worldwide and remains highly morbid even with highly monitored medical therapy. Recent results of the SAMMPRIS trial, which randomized patients to stenting plus aggressive medical management versus aggressive medical management alone have shown that additional treatment of intracranial atherosclerotic lesions with the Wingspan stent is inferior to aggressive medical management alone. In light of these results, there has been renewed interest in angioplasty alone to treat symptomatic ICAD. This article will briefly review the natural history of ICAD and discuss the possible future for endovascular treatment of ICAD with primary intracranial angioplasty in appropriately selected patients. PMID:24782816

  6. Superior caval venous syndrome after atrial switch procedure: relief of complete venous obstruction by gradual angioplasty and placement of stents.

    Science.gov (United States)

    Michel-Behnke, I; Hagel, K J; Bauer, J; Schranz, D

    1998-10-01

    Superior caval venous syndrome is one of the late problems known to occur after Mustard repair of complete transposition. Reoperation may leave residual stenosis, and carries substantial risk for the patient. It is now feasible to use intravascular stents to overcome systemic venous baffle obstructions, and such an approach is probably more effective. The purpose of our study therefore, was to assess immediate and medium term results of inserting stents subsequent to gradual balloon enlargement of acquired atresia of the intraatrial baffle in patients who had undergone an atrial switch operation. We investigated five patients with complete obstruction of the superior caval venous pathway at perforation of the atretic segment was achieved using a guide wire technique. The procedure was successful in all patients. Gradual angioplasty was performed and intravascular stents were implanted. The pressure in the superior caval vein dropped to normal values, symptoms improved, and the patency of the newly created venoatrial communication was proven at mid-term follow-up. Thus critical obstructions at the superior caval venous pathway after the Mustard procedure can be reopened by interventional catheterization. Implantation of balloon-expandable intravascular stents is safe and effective in the acute relief of the obstructions, but careful long-term follow-up is mandatory. PMID:9855097

  7. The challenge to balloon science

    Science.gov (United States)

    Jones, W. Vernon

    A thorough review of the NASA balloon program in 1995 confirmed both the inherent importance of balloon science investigations and their value for developing technology for future space missions. A follow-on study in 1996 looked into restructuring the entire suborbital program, in order to find more efficient and effective ways of doing business. These studies were mandated by the adverse impact of NASA's declining budgets and work force constraints on all aspects of space research. The challenge is to accomplish more with less. The balloon program began stepping up to this challenge several years ago with the advent of 10 - 20 day long-duration flights in Antarctica. We must now push ahead with enhanced flight capabilities and with new science instrument technologies, as we forge alliances with other modes of low-cost access to space. Specifically, the development of sealed superpressure balloons could extend flight duration by another order of magnitude, to about 100 days, making ballooning even more competitive with space missions.

  8. BLOCKING SUN WITH ORBITING BALLOONS

    Energy Technology Data Exchange (ETDEWEB)

    Chul Park [Department of Aerospace Engineering, Kor ea Advanced Institute of Science and Technology, Daejeon (Korea)

    2008-09-30

    Sun's radiation power reaching Earth's surface can be reduced by letting large balloons circle the Earth in orbits at approximately 1000 km altitude. These balloons, made of plastic films 1 mm in thickness, of a diameter of approximately 46 km, will weigh about 10,000 tons each. A balloon will consist of one hundred of 100 ton pieces. They are transported to the orbit piece by piece, and are assembled there into the spherical shape. They are kept inflated with the vapor pressure of potassium and the electrostatic forces. The inclination angles of these balloons with respect to the solar ecliptic plane can be varied from zero to 90 degrees, although efficiency is highest with the zero degree inclination. If zero degree inclination is chosen, twenty-three of these will reduce the average sun's radiation by 0.01%. In the 1000 km orbits, which are stable and are populated only by space debris, these balloons will serve also to remove the debris.

  9. Sensor System for Super-Pressure Balloon Performance Modeling Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Long-duration balloon flights are an exciting new area of scientific ballooning, enabled by the development of large super-pressure balloons. As these balloons...

  10. Balloon Exoplanet Nulling Interferometer (BENI)

    Science.gov (United States)

    Lyon, Richard G.; Clampin, Mark; Woodruff, Robert A.; Vasudevan, Gopal; Ford, Holland; Petro, Larry; Herman, Jay; Rinehart, Stephen; Carpenter, Kenneth; Marzouk, Joe

    2009-01-01

    We evaluate the feasibility of using a balloon-borne nulling interferometer to detect and characterize exosolar planets and debris disks. The existing instrument consists of a 3-telescope Fizeau imaging interferometer with 3 fast steering mirrors and 3 delay lines operating at 800 Hz for closed-loop control of wavefront errors and fine pointing. A compact visible nulling interferometer is under development which when coupled to the imaging interferometer would in-principle allow deep suppression of starlight. We have conducted atmospheric simulations of the environment above 100,000 feet and believe balloons are a feasible path forward towards detection and characterization of a limited set of exoplanets and their debris disks. Herein we will discuss the BENI instrument, the balloon environment and the feasibility of such as mission.

  11. Transcutaneous angioplasty of vertebral artery atheromatous ostial stricture

    International Nuclear Information System (INIS)

    The authors report experience of intravascular angioplasty of atheromatous ostial strictures of the vertebral artery in 24 patients. After reviewing the technique, they authive the indications provided through Doppler velocimetric data. The results seem to be encouraging as symptoms disappeared completely in 21 patients. (orig.)

  12. Subintimal angioplasty: predictors of long-term success.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2009-08-01

    To determine the clinical outcomes and success rates after percutaneous subintimal angioplasty (SIA) in patients with lower-limb occlusive lesions causing intermittent claudication (IC) or critical limb ischemia (CLI) at midterm to long-term follow-up. The secondary aim was to elicit factors predictive of a successful outcome.

  13. Percutaneous coronary angioplasty in a cardiac transplant recipient.

    OpenAIRE

    Gammage, M D; Shiu, M F; English, T A

    1988-01-01

    Two years after an orthotopic cardiac transplant a 28 year old man was found to have clinically significant stenosis of the right coronary artery at routine coronary angiography. This lesion was accompanied by a perfusion defect on exercise thallium scintigraphy. Percutaneous transluminal coronary angioplasty of the lesion improved the angiographic appearance of the stenosis and reduced the exercise thallium perfusion defect.

  14. Transluminal angioplasty in the management of mesenteric angina

    International Nuclear Information System (INIS)

    The efficacy of transluminal angioplasty for the treatment of peripheral atherosclerotic disease has been well documented. The successful treatment of abdominal angina has been reported, although the follow-up is too short to accurately evaluate the long term results of this procedure. (orig.)

  15. Fatty acid metabolic disorder detected by 123I-BMIPP SPECT shortly after elective percutaneous transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    To evaluate clinical significance of decreased or unchanged BMIPP uptake in repeated SPECT, 23 patients underwent BMIPP SPECT before elective PTCA (BM-1), soon after PTCA (72 hours, BM-2), and 3 months later (BM-3). SPECT imagings were divided into 7 segments and were semi-quantitatively evaluated by 2 cardiologists in the blinded fashion. Decreased uptake at BM-2 compared with BM-1 was evaluated by comparing with stress Thallium-201 SPECT performed in the same schedule but on the different date (Tl-1,2,3), ischemic manifestation at PTCA, and wall motion change of LVG. Patients with restenosis were excluded from this study. BM-2 showed decreased uptake in 14 (61%), unchanged in 2 (9%), and increased in 7 (30%) patients, while stress Tl showed increased perfusion in all patients. Among 91 myocardial segments correspondent to PTCA vessels, 30 (33%) showed overt uptake reduction, and only 13 (14%) segments showed increased uptake. BM-2 uptake reduction was significantly associated with the absence of collateral artery (odds ratio, OR=3.1, p<0.01), multi vessel disease (OR=2.0, p=0.01), total balloon inflating time (p<0.05), ST elevation on ECG (OR=3.6, p=0.01), chest pain during PTCA (OR=3.1, p<0.1), while pre-dilatation by using small size balloon catheter prevented BM-2 uptake reduction (OR=6.0, p=0.01). Multiple logistic regression analysis showed that chest pain, balloon inflating time and pre-dilatation were independently associated with BM-2 uptake reduction. Three months after PTCA, the segments with BM-2 reduction hail stress Tl uptake similar to the segments without BM-2 reduction, however, they showed poorer recovery of BM-3 uptake and LV wall motion. BMIPP uptake reduction shortly after angioplasty was associated with ischemic manifestation and poor LV motion recovery, thus, it may be a sensitive representation of the stunned myocardium. (J.P.N.)

  16. Ballonnen in zee = balloons as marine litter

    NARCIS (Netherlands)

    Franeker, van J.A.

    2008-01-01

    Releasing balloons seems harmless. However, remains of balloons, especially valves and ribbons are becoming a common and persistent type of marine litter found on beaches. Following Dutch Queens day 2007, large numbers of Dutch balloons were found in Normandy, France. Animals may become entangled in

  17. Global electrodynamics from superpressure balloons

    Science.gov (United States)

    Holzworth, R. H.; Hu, H.

    1995-01-01

    Electric field and conductivity measurements in the stratosphere between November 1992 and March 1993 have been made using superpressure balloons in the southern hemisphere. Over 400 payload-days of data have been made during a record setting experiment called ELBBO (Extended Life Balloon Borne Observatories). This experiment resulted in 4 flights aloft simultaneously for over 2 months including one flight which lasted over 4 months. Electrodynamical coupling between the atmosphere and ionosphere is studied using the measured electric fields, and a simple empirical model of the stratospheric conductivity. Altitude profiles of conductivity have been obtained from several superpressure balloon flights using the large end-of-flight altitude swings on the last few days of each flight (as the balloon begins to loose superpressure). Coupling between the fields and atmospheric inertial waves has been observed. Effects and dynamics of the global circuit suggest that standard models are missing significant phenomena. Large scale ionospheric convection activity has been studied from the polar cap to the middle latitudes. Cusp latitude fields have been continuously measured for many days in a row.

  18. Early outcome of high energy Laser (Excimer) facilitated coronary angioplasty ON hARD and complex calcified and balloOn-resistant coronary lesions: LEONARDO Study

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosini, Vittorio; Sorropago, Giovanni; Laurenzano, Eugenio [Montevergine Clinic, Mercogliano (Italy); Golino, Luca, E-mail: lucagolino.jazz@alice.it [Montevergine Clinic, Mercogliano (Italy); Moriggia-Pelascini Hospital, Gravedona, Como (Italy); Casafina, Alfredo; Schiano, Vittorio [Montevergine Clinic, Mercogliano (Italy); Gabrielli, Gabriele [University Hospital Ospedali Riuniti, Ancona (Italy); Ettori, Federica; Chizzola, Giuliano [Spedali Civili University Hospital, Brescia (Italy); Bernardi, Guglielmo; Spedicato, Leonardo [University Hospital S. Maria Misericordia, Udine (Italy); Armigliato, Pietro [Istituto Italiano Ricerche Mediche, Verona (Italy); Spampanato, Carmine [Telethon Institute of Genetics and Medicine (TIGEM), Naples (Italy); Furegato, Martina [Istituto Italiano Ricerche Mediche, Verona (Italy)

    2015-04-15

    Aim: An innovative xenon–chlorine (excimer) pulsed laser catheter (ELCA X80) has been recently used for the treatment of complex coronary lesions, as calcified stenosis, chronic total occlusions and non-compliant plaques. Such complex lesions are difficult to adequately treat with balloon angioplasty and/or intracoronary stenting. The aim of this study was to examine the acute outcome of this approach on a cohort of patients with coronary lesions. Methods and Results: Eighty patients with 100 lesions were enrolled through four centers, and excimer laser coronary angioplasty was performed on 96 lesions (96%). Safety and effectiveness data were compared between patients treated with standard laser therapy and those treated with increased laser therapy. Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success in was obtained in 87 lesions (90.6%). There was no perforation, major side branch occlusion, spasm, no-reflow phenomenon, dissection nor acute vessel closure. Increased laser parameters were used successfully for 49 resistant lesions without complications. Conclusions: This study suggests that laser-facilitated coronary angioplasty is a simple, safe and effective device for the management of complex coronary lesions. Furthermore, higher laser energy levels delivered by this catheter improved the device performance without increasing complications. - Highlights: • We planned this multicenter study to examine the acute outcome of an innovative xenon–chlorine (excimer) pulsed laser catheter (ELCA X80) for treatment of complex coronary lesions. • We enrolled 80 patients with 100 lesions and performed excimer laser coronary angioplasty in 96 lesions (96%). • Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success was obtained in 87 lesions (90.6%). • Increased laser parameters were used successfully for 49 resistant

  19. Preparatory catheter-directed thrombolysis together with assisted endovascular angioplasty for the treatment of chronic occlusive arterial disorders of lower extremities

    International Nuclear Information System (INIS)

    Objective: To evaluate the safety and efficacy of preparatory catheter-directed thrombolysis together with assisted endovascular angioplasty in treating chronic occlusive arterial disorders of lower extremities. Methods: From January 2008 to December 2009, preparatory catheter-directed thrombolysis together with assisted endovascular angioplasty was performed in 12 patients with chronic occlusive arterial disorders of lower extremities, including 8 males and 4 females with an average age of 56.3 years (within a range of 38-71 years). All 12 patients had a history of chronic ischemia of lower limb,the mean ill duration was 19.3 months (3-48 months). All patients complained of intermittent claudication with a mean distance of 125 m (50-200 m). Rest pain occurred in 5 patients (42%), toe necrosis was seen in 3 patients (25%) and critically ischemic limb in 4 patients (33%). Ankle-brachial index (ABI) was 0.00 0.65 with a mean of 0.33. In all 12 patients catheter-directed thrombolysis with rt-PA or urokinase was initially carried out, which was followed by endovascular angioplasty (balloon dilatation or stent placement) in two days. The clinical data and the therapeutic results were analyzed. Results: Technical success was achieved in all 12 patients. The mean time of thrombolysis was 48 hours. Of 12 patients, rt-PA was employed in 4 and urokinase in 8. The occluded length of the diseased arteries before the treatment was 60-150 mm, with a mean of 80 mm. After catheter-directed thrombolysis,the occluded length decreased to 10-50 mm (mean of 30 mm). Endovascular angioplasty was successfully completed in all patients after thrombolysis therapy. Postoperative ABI was 0.64-1.0 (mean of 0.86), which was increased by 0.53 when compared to the preoperative figure. During the perioperative period neither complications needed to be surgically treated nor death occurred. All patients were followed up, and the arteries remained open after one year in all cases. Conclusion

  20. Angioplasty in patients with vertebrobasilarintracranial atherosclerotic stenosis and stenting of the vertebral artery ostium: results from a single center experience

    International Nuclear Information System (INIS)

    Full text: Medical therapy in patients with TIA or stroke in the vertebrobasilar system (VBS) is not always optimal to change the natural history of the disease. Alternative treatment includes endovascular angioplasty with and without stenting. The purpose of the study was to report the results from angiography and clinical outcome in a small cohort of patients with VBS pathology who underwent angioplasty and/or stenting. Fourteen patients (mean age of 60.5 ±8.4 years) were treated. All patients underwent digital subtractive cerebral angiography to find a stenosis that met criteria for endovascular therapy. Neuroimaging before procedure included angio-CT/MRI. extra and transcranial colour duplex scanning was used for hemodynamic evaluation of the stenosis and recanalization before, and 1 year after the treatment. Clinical outcome according to modified Rankin Scale (mRS) and mortality were assessed on day 90 and one year after the treatment. Standard medical treatment was given to all patients. Results: TIA had 9 patients, and previous stroke had 8 patients.Left vertebral artery (VA) was affected in 6 patients, right in 8 patients. Tandem VS stenoses had 1 patient (ostium and VA4-segment). Contralateral VA thrombosis was found in 4 patients and a hypoplastic VA in 1. Mean degree of VBS stenosis in all patients was 87.5 ±7.2%. Successful balloon angioplasty of the intracranial AV4 stenosis was achieved in 3 patients, however not in one other with a severe basilar artery stenosis. Eight patients with extracranial atherosclerotic stenosis of the ostium (VAO) and 1 with right VA1 dissection received stents with excellent angiogpahic results. Balloon predialtation was achieved with mean pressure of 10.8 ±2.8 mm Hg.The mean length of the stents was 18.3 ±11.2 mm, with mean diameter 4.2 mm. Types of stents used were: 1 Pulsar, 1 Integrity, 2 orsiro, 1 CristalloIdeale, 1 energy, and 3 drug eluding stents endeavor Resolute. Mean scopia time was 8.5 ±8 minutes, and mean

  1. Left main coronary stenosis as a late complication of percutaneous angioplasty:an old problem,but still a problem

    Institute of Scientific and Technical Information of China (English)

    Giuseppe Faggian; Gianluca Rigatelli; Francesco Santini; Giuseppe Petrilli; Paolo Cardaioli; Loris Roncon; Alessandro Mazzucco

    2009-01-01

    Objective Accelerated left main coronary stenosis (LMCS) is a known potential late complication of coronary artery catheter procedures. The aim of this study was to assess the current occurrence of LMCS as a delayed complication of percutaneous angioplasty (PTCA) of the left coronary branches in our institution. Methods The medical records of patients referred for coronary artery by-pass surgery from the same Cardiology Unit in the January 2003 to December 2006 period and presenting a significant (> 50%) LMCS as a new finding following a PTCA of the left coronary artery branches, were reviewed. Patients with retrospective evidence of any LMCS at previous coronary angiographies preceding the percutaneous procedure were excluded. Results Thirty-seven patients (5 females, mean age 71.1±8.6 years) out of 944 (4%) having undergone a PTCA, fulfilled the inclusion criteria, 19 (51%) after a procedure also involving the LAD coronary artery. Extraback-up guiding catheters were used in most cases. Use of multiple wires or balloons was observed in 3 cases (8%). Rotablator and proximal occlusion device were used in one case respectively (3%). Twenty patients (54%) have had more than one percutaneous coronary intervention on the left coronary branches. The mean time elapsed from the first angioplasty and surgical intervention was 18.1±7.8 months. Conclusions The potential occurrence of LMCS following a percutaneous intervention procedure, especially when complicated and repeated, should not be underestimated in the current era. This evidence may offer the rationale to schedule non-invasive imaging tests to monitor left main coronary patency after the procedure as well as to fuel further research to develop less traumatic materials.

  2. Angioplasty and stent placement in chronic occlusion of the superficial femoral artery: technique and results.

    OpenAIRE

    Conroy, RM; Gordon, IL; Tobis, JM; Hiro, T; Kasaoka, S; Stemmer, EA; Wilson, SE

    2000-01-01

    PURPOSE: To improve the patency rate for angioplasty in chronic occlusion of the superficial femoral artery by deploying stents after angioplasty. MATERIALS AND METHODS: Angioplasty and stent placement were performed in 61 arteries in 48 male patients. The mean occlusion length was 13.5 cm and the mean stent length was 30 cm. Patency rates were analyzed at 6 months and at 1, 2, 3, and 4 years. The predictors of restenosis were analyzed by univariate and multiple logistic regression. RESULTS: ...

  3. Deep arterial injury during experimental angioplasty: relation to a positive indium-111-labeled platelet scintigram, quantitative platelet deposition and mural thrombosis

    International Nuclear Information System (INIS)

    Although it is not clear why coronary occlusion and restenosis occur after successful coronary angioplasty, factors related to the procedure may influence early and late results. The possible adverse effects of a medial tear documented histologically and produced during balloon angioplasty of the common carotid arteries were studied in 30 fully heparinized (100 U/kg body weight) normal pigs. Scanning electron microscopy showed endothelial denudation and extensive platelet deposition in all dilated arterial segments. Visible macroscopic mural thrombus was present within an hour of the procedure in 29 (91%) of the 32 arteries that had a medial tear documented by histologic study; the tear produced an indium-111-labeled platelet deposition of 116.4 +/- 26.5 X 10(6)/cm2 (mean +/- SE) and total thrombotic occlusion in 2 arteries (4%). None of the 24 arteries without a medial tear had a thrombus, and the mean platelet deposition in that group was 7.0 +/- 0.5 X 10(6)/cm2 (p less than 0.0008). In 12 pigs scanned with a gamma camera, visible thrombus was associated with platelet deposition in excess of 20 X 10(6)/cm2 in 12 arteries, 9 of which had a positive indium-111-labeled platelet scintigram. Thus, arterial angioplasty causes deep arterial injury, which appears to be a major cause of mural thrombosis, heavy platelet deposition, a positive indium-111-labeled platelet scintigram and acute arterial occlusion. A positive indium-111-labeled platelet scintigram was always associated with macroscopic thrombus of at least 20 > 10(6) platelets/cm2 and underlying deep arterial injury

  4. A Mars 2011 Balloon Mission Trade Study

    Science.gov (United States)

    Smith, I.; Lew, T.; Perry, W.

    Mars Scouts are competitively selected PI-led missions to further Mars exploration in ways that satisfy NASA s overall objectives but are not currently in the planned line of missions The current 2006 Announcement of Opportunity AO for Mars Scouts has just closed The goal of this SwRI study was to develop a new balloon mission concept to where it could be credibly proposed for the AO The balloon system was defined in the study as consisting of two parts the balloon flight system BFS and the balloon deployment inflation system DIS The BFS includes the balloon envelope accessory hardware and gondola The balloon includes the envelope seams end fittings load core inflation tube diffusers payload tether shock attenuator and separation hardware The DIS includes the balloon container deployment hardware sequencer tankage gas and control hardware Trade studies were performed to better define the mission design space These studies included 1 effect of varied atmospheric thermal loads 2 effect of varying latitudes 3 effect of payload mass for varying altitudes 4 effect of radiative material properties on balloon size mass 5 effect of material areal densities on balloon size mass and 6 effect of inflation gas on system masses Results of the balloon trade study for the Mars 2011 mission opportunity will be presented

  5. PEBS - Positron Electron Balloon Spectrometer

    CERN Document Server

    Von Doetinchem, P; Kirn, T; Yearwood, G R; Schael, S

    2007-01-01

    The best measurement of the cosmic ray positron flux available today was performed by the HEAT balloon experiment more than 10 years ago. Given the limitations in weight and power consumption for balloon experiments, a novel approach was needed to design a detector which could increase the existing data by more than a factor of 100. Using silicon photomultipliers for the readout of a scintillating fiber tracker and of an imaging electromagnetic calorimeter, the PEBS detector features a large geometrical acceptance of 2500 cm^2 sr for positrons, a total weight of 1500 kg and a power consumption of 600 W. The experiment is intended to measure cosmic ray particle spectra for a period of up to 20 days at an altitude of 40 km circulating the North or South Pole. A full Geant 4 simulation of the detector concept has been developed and key elements have been verified in a testbeam in October 2006 at CERN.

  6. Below knee angioplasty in elderly patients: Predictors of major adverse clinical outcomes.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2011-03-01

    To determine predictors of clinical outcome following percutaneous transluminal angioplasty (PTA) in elderly patients with below knee atherosclerotic lesions causing intermittent claudication (IC) or critical limb ischaemia (CLI).

  7. The Case for Angioplasty in Patients with Symptomatic Intracranial Atherosclerosis

    Directory of Open Access Journals (Sweden)

    Ryan A Mctaggart

    2014-04-01

    Full Text Available Intracranial atherosclerotic disease (ICAD is likely the most common cause of stroke worldwide and remains highly morbid even with highly monitored medical therapy. Recent results of the SAMMPRIS trial which randomized patients to stenting plus aggressive medical management versus aggressive medical management alone have shown that additional treatment of intracranial atherosclerotic lesions with the Wingspan stent is inferior to aggressive medical management alone. In light of these results there has been renewed interest in angioplasty alone to treat symptomatic ICAD. This article will briefly review the natural history of intracranial atherosclerotic disease (ICAD and discuss the possible future for endovascular treatment of ICAD with primary intracranial angioplasty in appropriately selected patients.

  8. Evaluation of a Dedicated Balloon Catheter for Infrapopliteal Difficult Calcified Lesions in Diabetic Patients With Critical Limb Ischemia

    International Nuclear Information System (INIS)

    The purpose of this study was to assess the technical performance and immediate procedural outcome of a new balloon catheter in the treatment of calcified lesions in infrapopliteal arterial disease. Sixty-one patients (81 vessels) with infrapopliteal arterial disease were evaluated. Seventy-four of the 81 treated vessels had total occlusions. The ReeKross 18 peripheral transluminal angioplasty catheter (ClearStream, Wexford, Ireland) is an 0.018-inch guidewire system with 4F sheath compatibility and a rigid shaft intended for enhanced pushability. Only technical procedural outcomes were recorded. In 37 of 61 patients (50 infrapopliteal severely stenosed or occluded vessels), an attempt with a standard balloon was made before the ReeKross 18 was used. In 24 patients, the ReeKross 18 was used as the primary catheter in 23 cases involving crural arteries and in 8 cases involving the foot. The ReeKross 18 crossed the lesion in 55 of 59 (93.2%) patients and 72 of 77 (94.5%) vessels, respectively. Postdilatation results for the 51 patients (64 target lesions) in whom ReeKross 18 balloon dilation was achieved showed <30% residual stenosis in all but 4 patients (5 lesions). Of the patients treated with the ReeKross 18 as the primary catheter, the technical success rate (no adjunctive treatment/stent) was obtained in 20 of 24 (83.3%) patients (27 of 31 [87.1%] target lesions). In the treatment of difficult calcified lesions, the choice of a high-pushability angioplasty catheter, such as the ReeKross 18, warrants consideration.

  9. Early Results with the Use of Heparin-bonded Stent Graft to Rescue Failed Angioplasty of Chronic Femoropopliteal Occlusive Lesions: TASC D Lesions Have a Poor Outcome

    Energy Technology Data Exchange (ETDEWEB)

    Kuhan, Ganesh, E-mail: gkuhan@nhs.net; Abisi, Said; Braithwaite, Bruce D.; MacSweeney, Shane T. R. [Nottingham University Hospitals, Vascular and Endovascular Unit, Queens Medical Centre (United Kingdom); Whitaker, Simon C.; Habib, Said B. [Nottingham University Hospitals, Department of Radiology, Queen' s Medical Centre (United Kingdom)

    2012-10-15

    Purpose: To evaluate early patency rate of the heparin-bonded stent grafts in atherosclerotic long femoropopliteal occlusive disease, and to identify factors that affect outcome. Methods: Heparin-bonded Viabahn stent grafts were placed in 33 limbs in 33 patients during 2009-2010. The stents were deployed to rescue failed conventional balloon angioplasty. Mean age was 69 (range 44-88) years, and 67 % (22 of 33) were men. Most procedures (21 of 33, 64 %) were performed for critical limb ischemia (33 % for rest pain, 30 % tissue loss). Kaplan-Meier plots and Cox regression analysis were used to identify significant risk factors. Results: The average length of lesions treated was 25 {+-} 10 cm, and they were predominantly TASC (Transatlantic Intersociety Consensus) D (n = 13) and C (n = 17) lesions. The median primary patency was 5.0 months (95 % confidence interval 1.22-8.77). The mean secondary patency was 8.6 months (95 % confidence interval 6.82-10.42). Subsequently, 4 patients underwent bypass surgery and 5 patients underwent major amputation. One patient died. There were 5 in-stent or edge-stent stenoses. Cox multivariate regression analysis identified TASC D lesions to be a significant risk factor for early occlusion (p = 0.035). Conclusion: TASC D lesions of femoropopliteal occlusions have poor patency rates with the use of heparin-bonded stent grafts after failed conventional angioplasty. Alternative options should be considered for these patients.

  10. Hyperspectral Polarimeter for Monitoring Balloon Strain Project

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's latest generation of superpressure, ultra long duration balloons (ULDB) extend the flight time for stratospheric experiments to levels previously...

  11. Efficacy of Drug-Eluting Balloons for Patients With In-Stent Restenosis: A Meta-Analysis of 8 Randomized Controlled Trials.

    Science.gov (United States)

    Gao, Shen; Shen, Jing; Mukku, Venkata Kishore; Wang, Mei Jia; Akhtar, Muzina; Liu, Wei

    2016-08-01

    The optimal treatment for in-stent restenosis (ISR) of both bare-metal stent (BMS) and drug-eluting stent (DES) is currently unclear. The aim of this meta-analysis was to assess the role of drug-eluting balloon (DEB) as an optional treatment for ISR. We searched PubMed, MEDLINE, EMBASE, BIOS, and Web of Science from 2005 to July 2014. Eight studies, enrolling 1413 patients were included. Main end points were late lumen loss (LLL), binary in-segment restenosis (BR), major adverse cardiac events (MACEs), target lesion revascularization (TLR), death, myocardial infarction (MI), and stent thrombosis (ST). When compared to plain old balloon angioplasty (POBA), DEB treatment significantly reduced the risk of MACE (risk rato [RR] 0.37, P option to treat ISR when compared to POBA. However, it had similar effects as DES. PMID:26483569

  12. Endovascular brachytherapy (EVBT) with rhenium-188 for restenosis prophylaxis after angioplasty of infrainguinal lesions. Early experience; Endovaskulaere Brachytherapie (EVBT) mit Rhenium-188 zur Restenoseprophylaxe nach Angioplastie infrainguinaler Laesionen. Erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Leissner, G.G.; Winterstein, A.; Bohndorf, K.; Wohlgemuth, W.A. [Klinikum Augsburg (Germany). Klinik fuer Diagnostische Radiologie und Neuroradiologie; Wengenmair, H. [Klinikum Augsburg (Germany). Medizinische Physik und Strahlenschutz; Sciuk, J. [Klinikum Augsburg (Germany). Klinik fuer Nuklearmedizin; Woelfle, K.D. [Klinikum Augsburg (Germany). Klinik fuer Gefaesschirurgie; Weinrich, K. [Klinikum Augsburg (Germany). II. Medizinische Klinik, Angiologie

    2011-08-15

    Purpose: Restenosis remains a major problem in percutaneous transluminal angioplasty (PTA) of peripheral arteries. The aim of this feasibility study was to evaluate the technical feasibility and safety of a new endovascular brachytherapy (EVBT) device with Rhenium-188 in restenosis prophylaxis of infrainguinal arteries. Materials and Methods: From March 2006 to April 2009, 52 patients with 71 infrainguinal arterial lesions were treated with Re-188 to prevent restenosis after PTA. 40 patients with 53 lesions (24 de-novo lesions and 29 restenoses) were reexamined (clinic, color-coded duplex ultrasound) after a mean follow-up period of 12.7 months (2.6 to 25.1 months). The liquid beta-emitter Re-188 was introduced to the target lesion via an EVBT certified PTA balloon and a tungsten applicator. After the calculated irradiation time, Re-188 was aspirated back into the tungsten applicator. A dose of 13 Gy was applied at a depth of 2 mm into the vessel wall. Results: After a mean follow-up of 12.7 months, the overall restenosis rate after Re-PTA was 15.1 % (8/53 lesions). The restenosis rate for de-novo lesions was 20.8 % (5/24) and 10.3 % for restenoses (3/29). In 4 patients reintervention was necessary (3 PTAs and 2 major amputations). No periprocedural complications were observed. No elevated radiation dose for the patient or the interventionalist was measured. Conclusion: EVBT with a Re-188 filled balloon catheter was technically feasible and safe after PTA of infrainguinal arterial lesions with restenosis rates lower than expected compared to published results. Treatment of restenoses seems to be more effective than de-novo lesions. (orig.)

  13. Paclitaxel-Coated Balloons: Review of a Promising Interventional Approach to Preventing Restenosis in Femoropopliteal Arteries.

    Science.gov (United States)

    Teleb, Mohamed; Wardi, Miraie; Gosavi, Sucheta; Said, Sarmad; Mukherjee, Debabrata

    2016-06-01

    Peripheral arterial disease (PAD), a major cause of morbidity and mortality worldwide, is characterized by intermittent claudication and is associated with chronic diseases such as diabetes and hypertension. The goal of treatment is to address the underlying cause and to modify risk factors. Although medical management is the first-line treatment of PAD, some individuals may have severe symptoms and require revascularization with percutaneous transluminal angioplasty with or without stent placement or surgery. Interventional approaches may, however, be associated with high prevalence of restenosis and subsequent complications such as critical limb ischemia and amputation. Drug-eluting balloons (DEBs) are a new interventional technology with the primary goal of preventing restenosis. We review the clinical trials and studies that assessed the efficacy and safety profile of DEB and will focus on the restenosis rate in femoropopliteal arteries including target lesion revascularization (TLR) and late lumen lesion (LLL) using different modalities of intervention such as stents and DEB. Average data collected from the trials reported included restenosis rate of 25%, 0.3 mm LLL, and 14% reduction in TLR with DEB versus uncoated balloons. Below the knee (BTK) only intervention studies were excluded from this review as endovascular approach is usually reserved for critical limb ischemia for BTK disease. Interventional approach to treat PAD with DEB appears to be a promising technology. Additional larger studies are needed to further define safety, efficacy, and longer term outcome with this novel technology. PMID:27231422

  14. A COMPARISON OF HIRUDIN WITH HEPARIN IN THE PREVENTION OF RESTENOSIS AFTER CORONARY ANGIOPLASTY

    NARCIS (Netherlands)

    SERRUYS, PW; HERRMAN, JPR; SIMON, R; RUTSCH, W; BODE, C; LAARMAN, GJ; VANDIJK, R; VANDENBOS, AA; UMANS, VAWM; FOX, KAA; CLOSE, P; DECKERS, JW

    1995-01-01

    Background. The likelihood of restenosis is a major limitation of coronary angioplasty. We studied whether hirudin, a highly selective inhibitor of thrombin with irreversible effects, would prevent restenosis after angioplasty. We compared two regimens of recombinant hirudin with heparin. Methods. W

  15. Impact of Diabetes on Long-Term Outcome After Primary Angioplasty

    DEFF Research Database (Denmark)

    De Luca, Giuseppe; Dirksen, Maurits T; Spaulding, Christian;

    2012-01-01

    Diabetes has been shown to be associated with worse survival and repeat target vessel revascularization (TVR) after primary angioplasty. The aim of the current study was to evaluate the impact of diabetes on long-term outcome in patients undergoing primary angioplasty treated with bare metal stents...

  16. Application of percutaneous angioplasty in the cases of vertebroclavicular steal syndrome

    International Nuclear Information System (INIS)

    The case of the percutaneous angioplasty method application for a patient with nonspecific aortoarteritis, subtotal stenosis of the left sybclavian artery with tendency to vertebro-clavicular steal syndrome is presented. Good results of treatment are shown and advantages of percutaneous angioplasty in the case of vertebro-clavicular steal syndrome are marked

  17. Percutaneous transluminal angioplasty of the superficial femoral artery by retrograde catheterization via the popliteal artery

    DEFF Research Database (Denmark)

    Tønnesen, K H; Sager, P; Karle, A; Henriksen, L; Jørgensen, B

    1988-01-01

    We report the results of 50 angioplasty procedures via the popliteal artery. A 3-year follow-up including control of blood pressures at ankle and toe levels show results comparable to reports in the literature. This new approach for angioplasty of the superficial femoral artery and eventually of ...

  18. Impact of diabetes on long-term outcome after primary angioplasty: insights from the DESERT cooperation

    NARCIS (Netherlands)

    Luca, G. De; Dirksen, M.T.; Spaulding, C.; Kelbaek, H.; Schalij, M.; Thuesen, L.; Hoeven, B. van der; Vink, M.A.; Kaiser, C.; Musto, C.; Chechi, T.; Spaziani, G.; Llera, L.S. Diaz de la; Pasceri, V.; Lorenzo, E. Di; Violini, R.; Suryapranata, H.; Stone, G.W.; cooperation, D.

    2013-01-01

    OBJECTIVE: Diabetes has been shown to be associated with worse survival and repeat target vessel revascularization (TVR) after primary angioplasty. The aim of the current study was to evaluate the impact of diabetes on long-term outcome in patients undergoing primary angioplasty treated with bare me

  19. Balloon dilatations of esophageal strictures

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jeong Jin; Juhng, Seon Kwan; Kim, Jae Kyu; Chung, Hyon De [Chonnam National University College of Medicine, Seoul (Korea, Republic of)

    1990-04-15

    Most benign esophageal strictures can be successfully dilated with conventional bougienage technique. But occasionally strictures are so tight, lengthy, or sometimes irregular that this technique fail, and surgical intervention is required. Since 1974 Gruentzig balloon catheter has succeed when used for strictures in the cardiac and peripheral vasculatures, the biliary and urinary tracts, the colon of neonates after inflammatory disease and also in the esophagus. Fluoroscopically guided balloon catheters were used to dilate 30 esophageal strictures in 30 patients over 3 years at Department of Diagnostic Radiology, Chonnam University, College of Medicine. The distribution of age was from 7 years to 71 days and the ratio of male to female was 15:15. The causes of benign stricture (23 cases) were post-operative strictures (13), chemical (4), achalasia (3), chronic inflammation (2), esophageal rupture (1) and those of malignant stricture (7 cases) were post-radiation stricture of primary esophageal cancer (6) and metastatic esophageal cancer (1). The success rate of procedure was 93% (28/30). The causes of failure were the failure of passage of stricture due to markedly dilated proximal segment of esophagus (1 case) and too long segment of stricture (1 case). Complication of procedure was the diverticular-formation of esophagus in 3 cases, but has no clinical significance in follow-up esophagography. In conclusion, fluoroscopically guided balloon dilation of esophageal stricture appears to be safe, effective treatment and may be have theoretical advantages over conventional bougienage and also should be considered before other methods of treatment are used.

  20. Balloon dilatations of esophageal strictures

    International Nuclear Information System (INIS)

    Most benign esophageal strictures can be successfully dilated with conventional bougienage technique. But occasionally strictures are so tight, lengthy, or sometimes irregular that this technique fail, and surgical intervention is required. Since 1974 Gruentzig balloon catheter has succeed when used for strictures in the cardiac and peripheral vasculatures, the biliary and urinary tracts, the colon of neonates after inflammatory disease and also in the esophagus. Fluoroscopically guided balloon catheters were used to dilate 30 esophageal strictures in 30 patients over 3 years at Department of Diagnostic Radiology, Chonnam University, College of Medicine. The distribution of age was from 7 years to 71 days and the ratio of male to female was 15:15. The causes of benign stricture (23 cases) were post-operative strictures (13), chemical (4), achalasia (3), chronic inflammation (2), esophageal rupture (1) and those of malignant stricture (7 cases) were post-radiation stricture of primary esophageal cancer (6) and metastatic esophageal cancer (1). The success rate of procedure was 93% (28/30). The causes of failure were the failure of passage of stricture due to markedly dilated proximal segment of esophagus (1 case) and too long segment of stricture (1 case). Complication of procedure was the diverticular-formation of esophagus in 3 cases, but has no clinical significance in follow-up esophagography. In conclusion, fluoroscopically guided balloon dilation of esophageal stricture appears to be safe, effective treatment and may be have theoretical advantages over conventional bougienage and also should be considered before other methods of treatment are used

  1. Simulation of stratospheric balloon environment

    International Nuclear Information System (INIS)

    The behavior of materials used for the construction of stratospheric balloons is studied at DERTS by means of irradiations performed in reals time and simulating the exact flight environment. Two chambers were designed in the laboratory and are described together with the experimental procedure. In order to reduce cost and save time, it is worth accelerating the simulation when only a preliminary evaluation of the sample's properties is required. For this reason, a systematic study was undertaken in order to evaluate the respective effects of different parameters on the material degradation. The results of this study are given

  2. Evaluation of effect of coronary angioplasty using dipyridamole 99mTc myocardial imaging

    International Nuclear Information System (INIS)

    To evaluate the effect of coronary angioplasty in patients with coronary artery disease, we performed dipyridamole 99mTc myocardial imaging pre-and post-angioplasty. Within one month, 97.8% myocardial segments showing redistribution before angioplasty became normal or improved after angioplasty, but none improved in segments showing 'fixed' defect only. Within one month, effective rate of treatment was 76.7% in 30 patients but 95.8% in 24 patients showing redistribution before angioplasty. Follow-up study within 6 months showed that the effective rate of treatment was 66.7% in 30 patients and 83.3% in 24 patients respectively. The myocardial imagings of three patients kept normal during one year follow-up. In 12.5% cases, the myocardial imaging showed reischemia which was confirmed by angiography

  3. The application of subintimal recanalization in percutaneous transluminal angioplasty for chronic long-segment occlusion of femoropopliteal artery

    International Nuclear Information System (INIS)

    Objective: To discuss the technical points and clinical efficacy of subintimal recanalization technique in treating chronic long-segment total occlusion of femoropoliteal artery. Methods: Forty-two patients with chronic long-segment total occlusion of femoropoliteal artery underwent subintimal recanalization treatment. The basic procedure of subintimal recanalization was as follows. First, a subintimal path in the wall of the occluded artery was created by inserting a super-slip guide wire and the guide wire was then pushed into the true lumen of the outflow tract, which was followed by balloon angioplasty and stent placement to insure the patency of the re-canalized path. The technical points were discussed and the clinical results were evaluated. Results: The subintimal recanalization of occluded arterial segment was successfully achieved in 39 patients. The clinical symptoms were promptly and remarkably relieved after the procedure. The technical success rate was 92.9% (39/42). Technical failure occurred in three patients because the guide wire could not be managed into the true lumen of the outflow tract. Conclusion: The subintimal recanalization is an effective and safe technique for the treatment of chronic long-segment total occlusion of femoropoliteal artery. (authors)

  4. Early Cosmic Ray Research with Balloons

    International Nuclear Information System (INIS)

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster

  5. Promising role of drug-coated balloons in the tibial vessels?

    Science.gov (United States)

    Langhoff, Ralf; Behne, Andrea; Buschmann, Eva

    2016-10-01

    In order to assess the role of drug-coated balloons (DCB) in below-the-knee (BTK) artery interventions, we analyzed randomized trials which compare coated to non-coated balloons and additionally a direct comparison of drug-eluting stents (DES) with DCB. As angioplasty with non-coated balloons is per guideline-recommendation still standard of care for below-the-knee artery endovascular treatment, we focused on the direct comparison of efficacy and clinical outcome data of both treatment modalities. Data from peer reviewed and published trials were consulted. For each single study, primary and secondary endpoints were reported and compared. Three single-center, non-core lab adjudicated trials showed encouraging data which suggests that DCB in BTK arteries effectively inhibit the risk of early restenosis, but the pivotal, prospectively randomized, multicenter, core lab adjudicated trials failed to match with these result. Limitations of DEB treatment and trials in BTK arteries had been reported, hence a technical evaluation of possible side effects of DCB treatment and of trial design was taken into account. On the basis of the results available, the distinguishing findings of drug eluting effects in the femoropopliteal region cannot be transferred to BTK arteries. Refinement of the existing DCB technology and of future trial design should be considered. To adjudicate on DCB technology applied for BTK treatment is premature and it is mandatory to be kept under evaluation, because the potential benefit, with respect to the compelling results in the femoropoliteal arteries, could be huge to improve endovascular BTK and especially CLI treatment. PMID:27465390

  6. Carotid angioplasty and stent placement for restenosis after endarterectomy

    International Nuclear Information System (INIS)

    Recurrent carotid stenosis following endarterectomy is a common complication, and reoperation may be associated with increased morbidity. The goal of this study was to determine the procedural safety and long-term complication rates of carotid angioplasty and stenting for recurrent stenosis. Of 248 consecutive carotid angioplasty and/or stenting procedures performed at our institution between March 1996 and November 2005, 83 procedures for recurrent stenosis following endarterectomy were performed in 75 patients (mean age 68 years; 43 men, 32 women) without cerebral protection devices. The patients' medical records were retrospectively reviewed for vascular imaging reports and available clinical follow-up. Procedural and long-term complication rates were calculated. Recurrent stenosis was reduced from a mean of 80.6% to no significant stenosis in 82 of 83 procedures. The procedural stroke rate was 3 out of 83 procedures (3.6%). The procedural transient ischemic attack (TIA) rate was 2 out of 83 procedures (2.4%). Mean follow-up was 22.4 months (range 0.1 to 86.7 months) with at least 6 months follow-up for 54 of 83 procedures (65%). There were five TIAs and no strokes on follow-up (new TIAs at 25.5 and 43.4 months; recurrent TIAs at 1, 11.1, and 12 months, all with normal angiograms). The composite 30-day stroke, myocardial infarction, or death rate was 5 of 83 procedures (6.0%). In this series, angioplasty and stenting were effective in relieving stenosis secondary to recurrent carotid disease after endarterectomy, and have low rates of ischemic complications. (orig.)

  7. Risk assessment after coronary angioplasty with SPECT myocardial perfusion studies

    International Nuclear Information System (INIS)

    The chest pain can be use for stratifying the risk of the patients after coronary angioplasty. Nevertheless this strategy has shown to have a low accuracy in the detection of restenosis and myocardial ischemia. Aims: To establish the usefulness of the SPECT studies in the risk stratification after the coronary angioplasty. Evaluate the incidence of silent ischemia or symptomatic, and its impact on the prognosis. Method: There were included 107 patients (p) submitted to a gated SPECT between the year of the coronary angioplasty. The analysis of the images was performed according to different scores (SSS, SRS, SDS). These data was correlated with the symptoms of the patients. We define group 1 (G1) as the asymptomatic without ischemia (n 59p), group 2 (G2) as silent ischemia (n = 28p) and group 3 (G3) as symptomatic with ischemia (n = 20p). A clinical follow-up was done in search of events (target vessel revascularization, unstable angina, AMI and death). Results: Significant differences were not observed in the clinical variables between the different groups. The SSS was lower in the G1 compare with G2 and G3 (p 0.0001) and was similar between the last two, p = NS (SSS: G1: 2.2 ± 4.9; G2: 7.6 ± 5.9; G3: 9.5 ± 6.8). The SDS was greater in G3 vs. G1 and G2, p = 0.0001, and greater in G2 vs. G1, p = 0.0001 (SDS: G1: 0; G2: 4.8 ± 3.5; G3: 7.2 ± 6.5). No differences where observed in the SRS between the three groups. In the follow-up the total percentage of events was lesser when compare the G1 with the G2 and G3 (G1: 3.3%; G2 and G3: 18.7%; p 0.02). The percentage of annual events of the G3 symptomatic with ischemia (11.03%) and G2 silent ischemia (4.04%) did not present differences (p 0.7). When the events of the G2 (4.04%) were compared with the G1 (1.24%) we observed a trend to major frequency of events in the G2 (p = 0.6). Conclusions: The presence of myocardial ischemia after coronary angioplasty is a determinant of the prognosis. Nevertheless, the extension

  8. Long-term results of brachiocephalic artery percutaneous transluminal angioplasty

    International Nuclear Information System (INIS)

    This paper establishes the ling-term and angiographic sequelae of percutaneous transluminal angioplasty (PTA) of stenoses of the origins of the brachycephalic arteries. From November of the proximal segments of the brachycephalic arteries. Clinical follow-up after PTA was 45 months. Two patients had recurrence of vertigo, after 16 and 75 months. There was no evidence of restenosis in the patient whose recurrence was after 16 months, but considerable restenosis was noted in the patient whose symptoms recurred after 75 months. That patient underwent successful repeated PTA

  9. Transluminar catheter angioplasty of abdominal aorta in Takayasu's arteritis

    International Nuclear Information System (INIS)

    Nine patients with Takayasu's arteritis and a long stenotic segment of the abdominal aorta were treated by percutaneous transluminal angioplasty (PTA). Intermittent claudication dissappeared in six of seven cases, the femoral pulse reappeared in all five; ankle/arm indices increased in seven cases; elevated blood pressure normalized in seven of eight cases. Seven patients were followed for 3 to 28 months. They were all free of symptoms from the lower extremities. In three patients with or without renal artery stenosis and with hypertension, the blood pressure decreased after PTA of the abdominal aorta only. PTA may be a valuable treatment in Takayasu's arteritis and stenosis of the abdominal aorta. (orig.)

  10. Percutaneous transluminal angioplasty after bypass operations on the lower extremities

    International Nuclear Information System (INIS)

    To prevent bypass thrombosis, percutaneous transluminal angioplasty (PTA) was performed on 32 stenoses in 25 patients following vascular surgery. Seventeen patients showed 23 stenoses at the level of the anastomoses or in the bypass itself; 8 patients exhibited 9 stenoses proximal or distal to the bypass. Twenty-two patients underwent successful PTA and showed an increase in the ankle/arm Doppler index from 0.38±0.13 to 0.76±0.11 after PTA. The long-term patency rates at 6, 12 and 24 months were 75%, 57% and 39%, respectively. The reason for three unsuccessful PTAs are discussed. (orig.)

  11. Successful technical and clinical outcome using a second generation balloon expandable coronary stent for transplant renal artery stenosis: Our experience

    Science.gov (United States)

    Salsamendi, Jason; Pereira, Keith; Baker, Reginald; Bhatia, Shivank S; Narayanan, Govindarajan

    2015-01-01

    Transplant renal artery stenosis (TRAS) is a vascular complication frequently seen because of increase in the number of renal transplantations. Early diagnosis and management is essential to optimize a proper graft function. Currently, the endovascular treatment of TRAS using angioplasty and/or stenting is considered the treatment of choice with the advantage that it does not preclude subsequent surgical correction. Treatment of TRAS with the use of stents, particularly in tortuous transplant renal anatomy presents a unique challenge to an interventional radiologist. In this study, we present three cases from our practice highlighting the use of a balloon-expandable Multi-Link RX Ultra coronary stent system (Abbott Laboratories, Abbott Park, Illinois, USA) for treating high grade focal stenosis along very tortuous renal arterial segments. Cobalt–Chromium alloy stent scaffold provides excellent radial force, whereas the flexible stent design conforms to the vessel course allowing for optimal stent alignment. PMID:26629289

  12. Successful technical and clinical outcome using a second generation balloon expandable coronary stent for transplant renal artery stenosis: Our experience.

    Science.gov (United States)

    Salsamendi, Jason; Pereira, Keith; Baker, Reginald; Bhatia, Shivank S; Narayanan, Govindarajan

    2015-10-01

    Transplant renal artery stenosis (TRAS) is a vascular complication frequently seen because of increase in the number of renal transplantations. Early diagnosis and management is essential to optimize a proper graft function. Currently, the endovascular treatment of TRAS using angioplasty and/or stenting is considered the treatment of choice with the advantage that it does not preclude subsequent surgical correction. Treatment of TRAS with the use of stents, particularly in tortuous transplant renal anatomy presents a unique challenge to an interventional radiologist. In this study, we present three cases from our practice highlighting the use of a balloon-expandable Multi-Link RX Ultra coronary stent system (Abbott Laboratories, Abbott Park, Illinois, USA) for treating high grade focal stenosis along very tortuous renal arterial segments. Cobalt-Chromium alloy stent scaffold provides excellent radial force, whereas the flexible stent design conforms to the vessel course allowing for optimal stent alignment. PMID:26629289

  13. Esophageal achalasia : results of balloon dilation

    International Nuclear Information System (INIS)

    To evaluate the clinical effectiveness of fluoroscopically guided balloon dilation in the treatment of esophageal achalasia. Under fluoroscopic guidance, 21 balloon dilation procedures were performed in 14 patients with achalasia. A balloon with a diameter of 20 mm was used for the initial attempt.If the patient tolerated this well, the procedure was repeated with a 10-20 mm balloon, placed alongside at the same session. If, however the patient complained of severe chest pain and/or a postprocedural esophagogram showed an improvement,the additional balloon was not used. For patients whose results were unsatisfactory, the dilation procedure was repeated at sessions three to seven days apart. Succesful dilation was achieved in 13 of 14 patients(92.9%), who needed a total of 20 sessions of balloon dilation, ranging from one to three sessions per patient(mean, 1.54 sessions). Esophageal rupture occured in one of 14 patients(7.1%) ; of the 13 patients who underwent a successful dilation procedure, 12(92.3%) were free of recurrent symptoms during the follow-up period of 1-56(mean, 18.5) months. The remaning patient(7.7%) had a recurrence seven months after dilation. Fluoroscopically guided balloon dilation seems to be safe and effective in the treatment of esophageal achalasia

  14. Esophageal achalasia : results of balloon dilation

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Won Woo; Kang, Sung Gwon; Yoon, Kwon Ha; Kim, Nam Hyeon; Lee, Hyo Jeong; Yoon, Hyun Ki; Sung, Kyu Bo; Song, Ho Young [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-08-01

    To evaluate the clinical effectiveness of fluoroscopically guided balloon dilation in the treatment of esophageal achalasia. Under fluoroscopic guidance, 21 balloon dilation procedures were performed in 14 patients with achalasia. A balloon with a diameter of 20 mm was used for the initial attempt.If the patient tolerated this well, the procedure was repeated with a 10-20 mm balloon, placed alongside at the same session. If, however the patient complained of severe chest pain and/or a postprocedural esophagogram showed an improvement,the additional balloon was not used. For patients whose results were unsatisfactory, the dilation procedure was repeated at sessions three to seven days apart. Succesful dilation was achieved in 13 of 14 patients(92.9%), who needed a total of 20 sessions of balloon dilation, ranging from one to three sessions per patient(mean, 1.54 sessions). Esophageal rupture occured in one of 14 patients(7.1%) ; of the 13 patients who underwent a successful dilation procedure, 12(92.3%) were free of recurrent symptoms during the follow-up period of 1-56(mean, 18.5) months. The remaning patient(7.7%) had a recurrence seven months after dilation. Fluoroscopically guided balloon dilation seems to be safe and effective in the treatment of esophageal achalasia.

  15. Intracoronary radiation therapy using Re-188 after percutaneous coronary angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Chae, In Ho; Lee, Myoung Mook; Lee, Dong Soo [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    1999-07-01

    Percutaneous coronary angioplasty is well established therapeutic modality in the management of coronary artery disease. However, the high restenosis rate of 30 to 50% limits its usefulness. The principal mechanism of restenosis, intimal hyperplasia, is the proliferative response of vessel wall to injury, which consists largely of smooth muscle cells. A large body of animal investigations and a limited number of clinical studies have established the ability of ionizing radiation to reduce neointimal proliferation and restenosis rate significantly. Human studies have been reported that intravascular radiation after first restenosis inhibits a second restenosis. Encouraged by these reports, we are also conducting a double blind, placebo-controlled, randomized trial to evaluate this new therapeutic modality in patients with coronary artery stenosis. The objective of our trial is to determine the safety and efficacy of catheter-based solutional beta emitting radioisotope system in preventing restenosis after angioplasty. This review describes the vascular brachytherapy systems and isotopes that have been utilized in the initial clinical trials performed in this area of past PTCA coronary restenosis. The results of many worldwide ongoing clinical trials will determine whether this new technology will change the future practice of vascular intervention.

  16. Exploring expectations and needs of patients undergoing angioplasty.

    Science.gov (United States)

    Aazami, Sanaz; Jaafarpour, Molouk; Mozafari, Mosayeb

    2016-09-01

    This study aimed to explore needs and expectations of Iranian patients who undergone angioplasty procedures. Coronary artery disease is the leading cause of morbidity and mortality worldwide. Recently, Percutaneous Coronary Intervention (PCI) has frequently been used as a substitute for coronary artery surgery, representing a less invasive and more cost-effective procedure. However, little information is known about the experiences and needs of patients undergone PCI. This research involved a qualitative study that employed the content analysis method. A semi-structured in-depth interview protocol was carried out using a face-to-face approach. Researchers reached to theoretical saturation by interviewing 18 patients who undergone angioplasty. Constant comparison analysis was used with simultaneous data collection. Three themes emerged from this study including Uncertainty, Procedural knowledge and Social Support. The findings from this study enhance our understanding on expectations and needs of patients who undergone PCI. These findings help nurses and health-care providers to develop and provide pre and post-procedural care according to each individual needs and experiences. This Iranian study not only contributes to other international study but also, emphasizes on the need for pre-procedural awareness and post-procedural support of patients who undergone PCI. PMID:27568316

  17. Airborne Internet Providing Tethered Balloon System

    Directory of Open Access Journals (Sweden)

    Suvriti Dhawan1

    2015-12-01

    Full Text Available In this paper we shall introduce a new system for providing wireless network communication over a specified area using ’lighter than air’ balloons. This technology will replace the existing fiber optic network system. This will be done by using a tethered balloon along with the payload (containing a receiver, a transmitter and a radio communication device.This payload will be suspended from the ground at an altitude (depending on the area of coverage required. Users under this area will be able to access this system directly for internet connectivity. This system can be used over large areas like universities, companies and societies to provide internet facility to their users through Wi-Fi or over an area where the user is specified (commercial purposes. Currently Google is working on similar idea called the ’Google Loon’ in which they use high altitude balloons which float at an altitude twice as high as air planes and the weather. They recently tested this system over New-Zealand by providing internet to their pilot testers on ground. Their balloons not being stationary, move with directional winds and have to be replaced one after the other to maintain consistency. This can be a huge problem over the areas where upper atmospheric winds are not in favorable direction. We can resolve this problem by using our stationary tethered balloon system which can communicate with the loon balloons to provide internet facility over a desired area. Moreover when our balloon will communicate with the loon balloon it will increase the coverage area as the loon balloon has to communicate to a point which is above the ground. Our system will not only replace the existing fiber optic system but it will also be selfsustaining i.e. It will generate its own power using solar panels.

  18. Investigating Diffusion and Entropy with Carbon Dioxide-Filled Balloons

    Science.gov (United States)

    Jadrich, James; Bruxvoort, Crystal

    2010-01-01

    Fill an ordinary latex balloon with helium gas and you know what to expect. Over the next day or two the volume will decrease noticeably as helium escapes from the balloon. So what happens when a latex balloon is filled with carbon dioxide gas? Surprisingly, carbon dioxide balloons deflate at rates as much as an order of magnitude faster than…

  19. Accurate Determination of the Volume of an Irregular Helium Balloon

    Science.gov (United States)

    Blumenthal, Jack; Bradvica, Rafaela; Karl, Katherine

    2013-01-01

    In a recent paper, Zable described an experiment with a near-spherical balloon filled with impure helium. Measuring the temperature and the pressure inside and outside the balloon, the lift of the balloon, and the mass of the balloon materials, he described how to use the ideal gas laws and Archimedes' principal to compute the average molecular…

  20. The balloon and the airship technological heritage

    Science.gov (United States)

    Mayer, N. J.

    1981-01-01

    The balloon and the airship are discussed with emphasis on the identification of commonalities and distinctions. The aerostat technology behind the shape and structure of the vehicles is reviewed, including a discussion of structural weight, internal pressure, buckling, and the development of a stable tethered balloon system. Proper materials for the envelope are considered, taking elongation and stress into account, and flight operation and future developments are reviewed. Airships and tethered balloons which are designed to carry high operating pressure with low gas loss characteristics are found to share similar problems in low speed flight operations, while possessing interchangeable technologies.

  1. Looners: Inside the world of balloon fetishism

    OpenAIRE

    McIntyre, Karen E

    2011-01-01

    In the spring of 1997, Shaun had just broken up with a boyfriend, and his roommate had moved out. Living alone for the first time and relieved of the fear that someone might walk in the door, he was finally able to indulge his fantasy. The young man sat on his couch and started blowing up balloons. Shaun had loved playing with balloons since he was a child. When he hit puberty, he felt his first orgasm rubbing against a balloon. It was then that his relationship with the object took ...

  2. Recent Developments in Balloon Support Instrumentation at TIFR Balloon Facility, Hyderabad.

    Science.gov (United States)

    Vasudevan, Rajagopalan

    2012-07-01

    The Balloon Facility of Tata Institute of Fundamental Research has been conducting stratospheric balloon flights regularly for various experiments in Space Astronomy and Atmospheric Sciences. A continuous improvement in Balloon flight Support instrumentation by the Control Instrumentation Group to keep in space with the growing complexities of the scientific payloads have contributed to the total success of balloon flights conducted recently. Recent improvements in display of Balloon position during balloon flight by showing on real time the balloon GPS position against Google TM maps is of immense help in selecting the right spot for payload landing and safe recovery . For further speeding up the payload recovery process, a new GPS-GSM payload system has been developed which gives SMS of the payload position information to the recovery team on their cell phones. On parallel footing, a new GPS- VHF system has been developed using GPS and Radio Modems for Balloon Tracking and also for obtaining the payload impact point. On the Telecommand side, a single board Telecommand/ Timer weighing less than 2 Kg has been specially developed for use in the mesosphere balloon test flight. The interference on the existing Short Range Telemetry System has been eliminated by introducing a Band Pass Filter and LNA in the Receiving system of the modules, thereby enhancing its reliability. In this paper , we present the details of the above mentioned developments.

  3. Shielded Mars Balloon Launcher (SMBL) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Aurora Flight Sciences, along with its partner Vertigo Industries, proposes a novel approach to deployment of balloon-based payloads into the Martian atmosphere....

  4. Retrieving Balloon Data in Flight Project

    Data.gov (United States)

    National Aeronautics and Space Administration —   NASA has plans to fly stratospheric ULDBs for missions of 100 days or more in the next few years. As these balloons circumnavigate the globe multiple...

  5. Attitude determination for balloon-borne experiments

    CERN Document Server

    Gandilo, N N; Amiri, M; Angile, F E; Benton, S J; Bock, J J; Bond, J R; Bryan, S A; Chiang, H C; Contaldi, C R; Crill, B P; Devlin, M J; Dober, B; Dore, O P; Farhang, M; Filippini, J P; Fissel, L M; Fraisse, A A; Fukui, Y; Galitzki, N; Gambrel, A E; Golwala, S; Gudmundsson, J E; Halpern, M; Hasselfield, M; Hilton, G C; Holmes, W A; Hristov, V V; Irwin, K D; Jones, W C; Kermish, Z D; Klein, J; Korotkov, A L; Kuo, C L; MacTavish, C J; Mason, P V; Matthews, T G; Megerian, K G; Moncelsi, L; Morford, T A; Mroczkowski, T K; Nagy, J M; Netterfield, C B; Novak, G; Nutter, D; O'Brient, R; Pascale, E; Poidevin, F; Rahlin, A S; Reintsema, C D; Ruhl, J E; Runyan, M C; Savini, G; Scott, D; Shariff, J A; Soler, J D; Thomas, N E; Trangsrud, A; Truch, M D; Tucker, C E; Tucker, G S; Tucker, R S; Turner, A D; Ward-Thompson, D; Weber, A C; Wiebe, D V; Young, E Y

    2014-01-01

    An attitude determination system for balloon-borne experiments is presented. The system provides pointing information in azimuth and elevation for instruments flying on stratospheric balloons over Antarctica. In-flight attitude is given by the real-time combination of readings from star cameras, a magnetometer, sun sensors, GPS, gyroscopes, tilt sensors and an elevation encoder. Post-flight attitude reconstruction is determined from star camera solutions, interpolated by the gyroscopes using an extended Kalman Filter. The multi-sensor system was employed by the Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry (BLASTPol), an experiment that measures polarized thermal emission from interstellar dust clouds. A similar system was designed for the upcoming flight of SPIDER, a Cosmic Microwave Background polarization experiment. The pointing requirements for these experiments are discussed, as well as the challenges in designing attitude reconstruction systems for high altitude balloon flights. ...

  6. Percutaneous transvenous balloon occlusion of arteriovenous fistula

    International Nuclear Information System (INIS)

    The closure of arteriovenous fistulas, using a balloon catheter introduced through the vein draining the fistula, is discussed. The application of this method to the closure of an iatrogenic vertebrovertebral fistula is described. (orig.)

  7. Magnetometer for Balloons and UAVs Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I SBIR project will investigate a new, low-cost approach to atomic magnetometry that is suited for operation from UAVs and research balloons. Atomic...

  8. Is echocardiography or magnetic resonance imaging superior for precoarctation angioplasty evaluation?

    Science.gov (United States)

    Mendelsohn, A M; Banerjee, A; Donnelly, L F; Schwartz, D C

    1997-09-01

    We compared the dimensions of the aorta obtained by two-dimensional transthoracic echocardiography (echo) (median, 2.5 mo preangioplasty) and magnetic resonance imaging (MRI) (median, 4.2 mo preangioplasty) to those obtained by angiography (cath) in 13 patients (age, 7.7 +/- 1.6 yr; mean +/- SEM) who underwent evaluation for coarctation balloon angioplasty between April 1993-January 1996. Echo measurements were obtained from the suprasternal and subcostal sagittal planes, MRI measurements from axial and sagittal oblique views, and cath measurements from the straight lateral or oblique views. Measurements of the diameters of the aortic isthmus, coarctation, descending aorta at the diaphragm, and isthmus length were made by all three modalities. Presence of aorto-aortic collaterals was determined, and the coarctation length was delineated. Investigators were blinded to other measurement data prior to statistical analysis. Data analysis by repeated analysis of variance (ANOVA) and Student-Newman-Keuls testing revealed no statistically significant difference between systolic pressure gradient by clinical examination (32.2 +/- 5.9 mm Hg), peak instantaneous Doppler evaluation (37.5 +/- 2.9 mm Hg), or preangioplasty systolic pressure gradient (32.1 +/- 3.3 mm Hg). With the exception of measurements of the descending aorta (echo, 11.7 +/- 0.9 mm vs. MRI, 13.3 +/- 0.8 mm vs. cath, 14.0 +/- 1.3 mm; P = 0.04), there was no statistically significant difference in dimensions of the aortic isthmus (9.2 +/- 0.6 mm vs. 10.5 +/- 0.9 mm vs. 10.8 +/- 0.9 mm), coarctation site diameter (4.8 +/- 0.6 mm vs. 5.6 +/- 0.9 mm vs. 5.3 +/- 0.8 mm), or isthmus length (12.4 +/- 2.1 mm vs. 12.1 +/- 2.2 mm vs. 10.9 +/- 1.7 mm). The correlation coefficients derived from comparisons of MRI vs. cath to echo vs. cath were similar for all dimensions except for isthmus length (P cardiac function and intracardiac anomalies. Both modalities detected the single patient with a long segment coarctation. We

  9. Test ventilation with smoke, bubbles, and balloons

    Energy Technology Data Exchange (ETDEWEB)

    Pickering, P.L.; Cucchiara, A.L.; McAtee, J.L.; Gonzales, M.

    1987-01-01

    The behavior of smoke, bubbles, and helium-filled balloons was videotaped to demonstrate the mixing of air in the plutonium chemistry laboratories, a plutonium facility. The air-distribution patterns, as indicated by each method, were compared. Helium-filled balloons proved more useful than bubbles or smoke in the visualization of airflow patterns. The replay of various segments of the videotape proved useful in evaluating the different techniques and in identifying airflow trends responsible for air mixing. 6 refs.

  10. Effects of a behavioural intervention on quality of life and related variables in angioplasty patients

    DEFF Research Database (Denmark)

    Appels, Ad; van Elderen, Therese; Bär, Frits;

    2006-01-01

    The EXhaustion Intervention Trial investigated the effect of a behavioural intervention programme on exhaustion, health-related quality of life (HRQL), depression, anxiety, hostility, and anginal complaints in angioplasty patients who felt exhausted after percutaneous coronary intervention (PCI)....

  11. Gondola development for CNES stratospheric balloons

    Science.gov (United States)

    Vargas, A.; Audoubert, J.; Cau, M.; Evrard, J.; Verdier, N.

    The CNES has been supporting scientific ballooning since its establishment in 1962. The two main parts of the balloon system or aerostat are the balloon itself and the flight train, comprising the house-keeping gondola, for the control of balloon flight (localization and operational telemetry & telecommand - TM/TC), and the scientific gondola with its dedicated telecommunication system. For zero pressure balloon, the development of new TM/TC system for the housekeeping and science data transmission are going on from 1999. The main concepts are : - for balloon house-keeping and low rate scientific telemetry, the ELITE system, which is based on single I2C bus standardizing communication between the different components of the system : trajectography, balloon control, power supply, scientific TM/TC, .... In this concept, Radio Frequency links are developed between the house keeping gondola and the components of the aerostat (balloon valve, ballast machine, balloon gas temperature measurements, ...). The main objectives are to simplify the flight train preparation in term of gondola testing before flight, and also by reducing the number of long electrical cables integrated in the balloon and the flight train; - for high rate scientific telemetry, the use of functional interconnection Internet Protocol (IP) in interface with the Radio Frequency link. The main idea is to use off-the-shelf IP hardware products (routers, industrial PC, ...) and IP software (Telnet, FTP, Web-HTTP, ...) to reduce the development costs; - for safety increase, the adding, in the flight train, of a totally independent house keeping gondola based on the satellite Inmarsat M and Iridium telecommunication systems, which permits to get real time communications between the on-board data mobile and the ground station, reduced to a PC computer with modem connected to the phone network. These GEO and LEO telecommunication systems give also the capability to operate balloon flights over longer distance

  12. Effects of granulocyte-macrophage colony stimulating factor on the repair of vessel intima damaged by balloon

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xing-hua; MA Xiao-jing; ZHAO Tong

    2005-01-01

    Background The dysfunction of vascular endothelial cells plays a key role in starting and facilitating restenosis. The acceleration of intima repair and the recovery of endothelial function would reduce the restenosis rate. This study was undertaken to assess the effect of granulocyte-macrophage colony stimulating factor (GM-CSF) on the repair of damaged iliac arteries.Methods Twenty-four male New Zealand white rabbits undergoing primary iliac artery deendothelialization were randomly divided into two groups (GM-CSF group and control group). The GM-CSF group received a subcutaneous injection of GM-CSF (10 μg·kg-1·d-1), and the control group was given a subcutaneous injection of equivalent saline. The iliac arteries of all animals were damaged by balloon after 7 days. The levels of nitric oxide (NO) were detected before, 1 week, 2 weeks and 4 weeks after angioplasty. The repair and hyperplasia of the intima were observed microscopically and the indices of stenosis were evaluated by computerized planimetry after 4 weeks of angioplasty.Results The NO levels of the GM-CSF group were higher than those of the control group 2 weeks and 4 weeks after angioplasty [(91.92±11.57) μmol/L vs. (81.67±12.18) μmol/L; (97.67±10.13) μmol/L vs. (83.16±12.64) μmol/L]. Four weeks after balloon damage, histological examination showed that neointima formation, vascular smooth muscle cells and fibrous tissue of the GM-CSF group were less than those of the control group. The endothelium of the GM-CSF group was more integrated, and stenosis of lumen was slighter than that of the control group. Morphometry showed the lumen area of the GM-CSF group was larger than that of the control group [(1.27±0.31) mm2 vs. (0.92±0.24) mm2], the neointimal area and percent of intima hyperplasia were significantly smaller than those of the control group [(0.85±0.34) mm2 vs. (1.18±0.38) mm2; (40±7)% vs. (55±6)%].Conclusion GM-CSF could facilitate the repair of the intima, reduce neointima

  13. Transcutaneous oximetry compared to ankle-brachial-index measurement in the evaluation of percutaneous transluminal angioplasty

    International Nuclear Information System (INIS)

    Objective: To investigate transcutaneous oximetry as parameter of the microcirculation is correlated to ankle-brachial-index as parameter of the macrocirculation after peripheral angioplasty procedures. Design: Prospective study. Materials and methods: 60 patients suffering from intermittent claudication were scheduled for angioplasty treatment. 45 patients were considered as eligible for angioplasty after angiographic evaluation, 15 patients underwent angiography only. Transcutaneous oximetry measurements were performed before the procedure, at the end of intervention, 24 h as well as 2 and 4 weeks after percutaneous transluminal angioplasty. Ankle-brachial-indices were obtained before intervention, 24 h as well as 2 and 4 weeks later. Results: Ankle-brachial-indices increased significantly at 24 h after angioplasty in patients being treated with angioplasty. Transcutaneous oximetry values dropped significantly at the end of the procedure and returned close to the baseline levels at 2 and 4 weeks after angioplasty. Ankle-brachial-indices and transcutaneous oximetry were positively correlated before (r = 0.3833, p = 0.009) as well as 4 weeks after angioplasty (r = 0.4596, p = 0.001). Immediately after radiological interventions, ankle-brachial-indices and transcutaneous oximetry are not positively correlated. In patients undergoing angiography only, transcutaneous oximetry levels drop significantly immediately after angiography and remain at decreased levels even at 4 weeks after intervention. Conclusion: Transcutaneous oximetry as parameter of the microcirculation is positively correlated with ankle-brachial-index as parameter of the macrocirculation before and at 4 weeks after angioplasty. Intraarterial angiography leads to a sudden decrease in skin microcirculation without affecting macrocirculation. As indicated by a lack of recovery in transcutaneous oximetry levels after 4 weeks, angiography alone results in a prolonged impaired microcirculation which may

  14. More accurate assessment of stenotic lesions in percutaneous transluminal angioplasty.

    Science.gov (United States)

    Janevski, B K; Breslau, P J; Jorning, P J

    1986-01-01

    Eighty patients underwent percutaneous transluminal dilatation and recanalisation of atheromatous lesions of the arteries of the lower extremities in the University Hospital of Maastricht in the period of 1980 to 1984. Out of 80 attempted procedures of the iliac and femoro-popliteal tract 71 (89%) were technically possible and were considered initially successful. In all cases of iliac artery lesions a retrograde arteriogram was performed prior to PTA. Intra-arterial pressure measurements at rest and after hyperemia were used for exact assessment of the hemodynamic significance of the stenosis before and after PTA. A follow-up of all patients successfully treated by angioplasty was performed. The early hemodynamic success rate of PTA for iliac lesions was 90 per cent and for femoral-popliteal segment 83 per cent. There was no morbidity or mortality. The cumulative 3-year patency rate for both segments was 74 per cent. PMID:2943842

  15. Radiation risk to patients from percutaneous transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    This paper reports that percutaneous transluminal coronary angioplasty (PTCA) is commonly used to control coronary atherosclerosis, and in many patients repeated applications occur. We investigated the current level of radiation dose and the corresponding risk for PTCA patients. The frequency of PTCA and patient demographics were also examined. Data for 1,503 Ottawa Heart Institute patients undergoing PTCA between January 1, 1987, and December 31, 1989, were analyzed retrospectively. Entrance exposures were estimated from records of the fluoroscopy time per case, the number of cine frames used, and exposure rate measurements. These were converted to average organ doses by using the Monte Carlo results of the Rosenstein group. Risks of including fatal cancers were estimated according to ICRP Report 60 (draft)

  16. ON THE SAFETY OF CONTRAST MEDIA USAGE DURING CORONARY ANGIOPLASTY IN KIDNEY TRANSPLANT RECIPIENTS

    Directory of Open Access Journals (Sweden)

    I. G. Ryadovoy

    2010-06-01

    Full Text Available In the present study influence of contrast media on renal transplant function in patients with ischemic heart disease treated by coronary angioplasty and stenting waz estimated. Results are based on clinical and angiographic data, the analysis of amount of contrast media, average speed of it introduction, level of creatinine before and at the first 48 hours after coronary angioplasty in 42 patients with renal transplant. 

  17. Matrix metalloproteinase 9 level as an indicator for restenosis following cervical and intracranial angioplasty and stenting

    OpenAIRE

    Jun-peng Liu; Yin-zhou Wang; Yong-kun Li; Qiong Cheng; Zheng Zheng

    2015-01-01

    Cervical and intracranial angioplasty and stenting is an effective and safe method of reducing the risk of ischemic stroke, but it may be affected by in-stent restenosis. The present study investigated serum level of matrix metalloproteinase 9 as a predictor of restenosis after 40 patients underwent cervical and/or intracranial angioplasty and stenting. Results showed that restenosis occurred in 30% (3/10) of patients when the serum level of matrix metalloproteinase 9 at 3 days after surgery ...

  18. Angioplasty of symptomatic high-grade internal carotid artery stenosis with intraluminal thrombus: therapeutic approach

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, A.; Mayol, A. [Seccion de Neurorradiologia Intervencionista, Servicio de Radiologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Gil-Peralta, A.; Gonzalez-Marcos, J.R. [Servicio de Neurologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Boza, F. [Servicio de Neurofisiologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Ruano, J. [Unidad de Cuidados Intensivos, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain)

    2004-04-01

    Intraluminal thrombus in the internal carotid artery (ICA) is usually found in patients with severe atheromatous stenosis. Having reviewed 300 carotid angioplasties for symptomatic >70% ICA stenosis, we found three patients (1%) with intraluminal thrombus. Conservative treatment with anticoagulants and double antiplatelet coverage can result in lysis of the thrombus without severe risks. Percutaneous transluminal angioplasty and stenting, preferably with distal protection, can be an excellent alternative to carotid endarterectomy. (orig.)

  19. Combination of Rotational Atherothrombectomy and Paclitaxel-Coated Angioplasty for Femoropopliteal Occlusion

    OpenAIRE

    Scheer, F; CW Lüdtke; P Kamusella; Wiggermann, P; Vieweg, H; Schlöricke, E; Lichtenberg, M.; R Andresen; Wissgott, C

    2015-01-01

    OBJECTIVE The rotational atherothrombectomy with Straub Rotarex® is a safe and efficient treatment of acute/subactute vascular occlusions. The purpose of this study was to evaluate the benefit of paclitaxel-coated angioplasty after rotational atherothrombectomy over an observation period of six months. MATERIALS AND METHODS Overall, 29 patients were treated with the Rotarex catheter in combination with paclitaxel-coated angioplasty. All patients had acute/subacute and chronic occlusions of th...

  20. Comparative efficacy of eptifibatide and abciximab in primary angioplasty study

    Directory of Open Access Journals (Sweden)

    Rohan Jayasinghe

    2011-02-01

    Full Text Available Rohan Jayasinghe1 Matias Yudi1 Sanjay Jayasinghe21Cardiology Department, Gold Coast Hospital, Griffith University, Queensland, Australia; 2Centre for Immunisation Research, Sydney, AustraliaBackground: Primary percutaneous intervention is the safest and most effective treatment modality for acute ST-segment elevation myocardial infarction (MI in centers where catheterization facilities exist. Intravenous glycoprotein IIb/IIIa inhibitor therapy during the procedures has been proven to provide added benefits. For the two agents, abciximab and eptifibatide, commonly used in this context, there is only limited comparative data available for the clinicians. Hitherto, there is no data published from the Asia–Pacific region on this topic.Method: A retrospective comprehensive analysis was carried out, comparing patients who were treated with abciximab (n = 125 and eptifibatide (n = 125 during primary angioplasty over a 3-year period. The primary outcome measure was in-hospital mortality. The other outcome measures studied include MI, stroke, blood transfusion, contrast nephropathy, significant bleeding, and vascular complications. A comparative cost analysis was carried out to ascertain the average overall differential cost.Results: In-hospital mortality, MI, stroke, blood transfusion, contrast nephropathy, significant bleeding, and vascular complication were observed at a higher rate in the patients who were treated with abciximab. However, these differences did not reach statistical significance. Due to the higher cost per unit and longer hospital stay, therapy with abciximab costs more than that with eptifibatide.Conclusions: Both abciximab and eptifibatide are safe and effective adjunct therapeutic agents in the setting of primary angioplasty. However, there is a trend toward higher adverse event with the former agent that was not statistically significant. Therapy with abciximab costs more per patient.Keywords: abciximab, eptifibatide, PCI, STEMI

  1. Cerebral angioplasty practice at major medical centers in the United States

    International Nuclear Information System (INIS)

    Concern has been expressed recently regarding the proliferation of angioplasty and/or stenting of cerebral vessels. However, little is known about the volume of angioplasties being performed or the number of experienced interventionalists. A questionnaire was mailed to directors of accredited radiology residency programs in the United States, to define the level of expertise available at teaching hospitals in terms of angioplasty and/or stenting. Of 200 programs surveyed, 111 responded (56 %). Of 111 program directors 47 (42 %) indicated that cerebral angioplasty was being performed at their center. The greatest experience is currently for angioplasty of post-subarachnoid hemorrhage vasospasm (mean 16 procedures performed) and the least experience for dilation of basilar artery atherosclerosis (mean five procedures performed). The reported stroke and/or death rate in centers performing angioplasty of the extracranial carotid system is 1.5 %. Comparisons with other medical specialties (e. g., cardiologists, neurologists, neurosurgeons) are necessary to determine the full scope of extracranial neurovascular procedures being performed and the corresponding complication rates. (orig.)

  2. The French Balloon Program 2013 - 2017

    Science.gov (United States)

    Dubourg, Vincent; Vargas, André; Raizonville, Philippe

    2016-07-01

    With over 50 years' experience in the field, the French Centre National d'Etudes Spatiales (CNES) goes on supporting - as designer and operator - a significant scientific ballooning program. In particular so because balloons still give a unique and valuable access to near space science. From 2008 to 2013, an important renovation effort was achieved, beginning by Zero Pressure Balloons (ZPB) systems, to comply with more stringent Safety constraints and to the growing reliability and performance requirements from scientific missions. The paper will give an overview of the CNES new capabilities and services for operational balloon activities, and their availability status. The scientific launch campaigns of the past two years will be presented. A focus will be made on the results of the Stratoscience 2015 flight campaign from Timmins, Ontario, using the NOSYCA command and control system for ZPB, qualified in flight in 2013. In particular, the PILOT telescope successfully flew during the 2015 campaign, key figures about the flight and mission will be given. An outlook of the new stratospheric long duration flight systems currently in process of developement at CNES will be given, as well as the presentation of the Stratéole 2 project, dedicated to the survey of the low stratosphere and upper troposphere in equatorial regions, with a fleet of small suprer pressure balloons (SPB). As far as tropospheric balloons are concerned, the Aeroclipper initiative will be presented, aiming at qualifying a quasi-tethered balloon, pushed by the winds close to the sea surface, for the study of cyclones. The scientific launch campaigns and the main payloads in the study for the near future will also be presented.

  3. Balloon dilatation of intrahepatic biliary strictures in liver transplantation

    International Nuclear Information System (INIS)

    Objective: To evaluate the efficacy of balloon dilatation in the treatment of intrahepatic biliary strictures in patients with liver transplantation. Methods: Of the 100 patients with liver transplantation, 16 patients had intrahepatic biliary strictures and received balloon dilatation treatment. Results: Initial technical balloon dilatation was successful in 14 caes but failed in 2 cases. There were no procedure-related complications. 4 restenosis occurred and they were treated with repeated balloon dilatation treatment. Conclusion: Balloon dilatation represented an effective and relatively safe treatment for biliary stricture in liver transplant recipients. For restenosis, balloon dilatation was also an effective treatment

  4. Brachytherapy using holmium-166 liquid balloon system for in-stent restenosis: 6 months clinical and angiographic follow-up

    International Nuclear Information System (INIS)

    In western country, 3 systems of brachytherapy using commercial radioactive source has been established. However, brachytherapy using holmium-166 liquid balloon system (HLBS) for the patient with stent restenosis has not been studied enough. 30 patients (male 23, mean age 58.9 7.7) were enrolled. Target dose was 15 Gy at 1 mm distance from the intimal surface. Clinical diagnoses of the study patients included stable angina 10 and unstable angina 20 patients. Target lesion included LAD 19, LCx 5 and RCA 6 arteries. Pre-brachytherapy treatment included cutting balloon angioplasty in 25, rotational atherectomy in 5 patients. Fractionation and stepping was done in 6 patients each. Follow-up angiography was done in 19 patients. Of them, 4 cases developed angiographic restenosis (21%) including 3 cases of total occlusion. 6 month MACE (major adverse cardiac event) occurred in 5 patients including one sudden cardiac death in a patient with 80 year-old, triple-vessel diseased patient. Vascular brachytherapy using HLBS is a safe and effective treatment modality for in-stent restenosis showing acceptable angiographic and clinical result

  5. Ballooning mode instability at the plasmapause

    Science.gov (United States)

    Lakhina, G. S.; Mond, M.; Hameiri, E.

    1990-01-01

    The ballooning mode instability, which can excite hydromagnetic waves at the plasmapause, is studied in the presence of azimuthal plasma flows induced during geomagnetically disturbed periods. A general sufficient criterion for the ballooning mode stability is derived, for a change in the potential energy greater than or equal to 0, which involves the integration over an entire field line. A local stability analysis at the equatorial plasmapause region shows that the ballooning modes could be spontaneously generated via instability under at least two conditions: one is similar to the usual interchange condition, and the second to the quasi-interchange modes. Both of these local instability conditions can be derived from the general stability criterion. Finally an exact solution for the equilibrium state with flow is derived analytically, and the change in the potential energy is computed numerically. It is found that, in the cases studied, the flow does not spontaneously excite the ballooning modes; it only further stabilizes (or destabilizes) the ballooning spectrum if originally the system is stable (or unstable). The analysis would be useful for the interpretation of some of the low-frequency modes observed at the ground and near the equatorial plasmapause.

  6. Near ultraviolet spectrograph for balloon platform

    Science.gov (United States)

    Sreejith, A. G.; Safonova, Margarita; Murthy, Jayant

    2015-06-01

    Small and compact scientific payloads may be easily designed constructed and own on high altitude balloons. Despite the fact that large orbital observatories provide accurate observations and statistical studies of remote and/or faint space sources, small telescopes on board balloons or rockets are still attractive because of their low cost and rapid response time. We describe here a near ultraviolet (NUV) spectrograph designed to be own on a high{altitude balloon platform. Our basic optical design is a modified Czerny-Turner system using off the shelf optics. We compare different methods of aberration corrections in such a system. We intend the system to be portable and scalable to different telescopes. The use of reflecting optics reduces the transmission loss in UV. We plan on using an image intensified CMOS sensor operating in photon counting mode as the detector of choice.

  7. Performance of latex balloons for optical computed tomography

    Science.gov (United States)

    Jordan, K.; Walsh, A.; Peng, M.; Battista, J.

    2013-06-01

    Latex balloons filled with radiation sensitive hydrogels were evaluated as 3D dosimeters with optical computed tomography (CT) readout. Custom balloons, with less than 10 cm diameters, were made from latex sheets. Commercial, 13 cm diameter, clear balloons were investigated for larger volumes. Ferrous-xylenol orange and genipin gelatin gels selected for 1 and 30 Gy experiments, respectively. The thin stretched latex membrane allowed optical imaging to within 1 mm of the interior balloon edge. Reconstructed dose distributions demonstrated valid measurements to within 2 mm of the balloon surface. The rubber membrane provides a hybrid approach to deforming hydrogels. Uniform irradiation of a deformed gel resulted in a uniform dose being measured when scanned in the relaxed, initial balloon shape. The 13 cm diameter balloons were also effective and inexpensive vessels for hydrogels due to their high clarity, thinness and mechanical strength. Latex balloons represent an inexpensive method to obtain useful information from nearly the entire dosimeter volume.

  8. Balloon catheter dilatation of esophageal strictures

    International Nuclear Information System (INIS)

    The authors performed 27 fluoroscopically guided balloon dilatation in 12 patients of esophageal stricture during recent 3 years. The causes of esophageal stricture were corrosive esophagitis (N=2) and congenital narrowing (N=1), including postoperative narrowing in achalasia (N=3), esophageal varix (N=3), lye stricture (N=2) and esophageal cancer (N=1). Successful dilatation of the stricture was achieved during the procedure in 10 patients(83%). Major complication such as esophageal rupture was not found. The authors conclude that fluoroscopically guided esophageal balloon dilatation is a safe and effective method for treatment of symptomatic esophageal strictures

  9. Balloon catheter dilatation of esophageal strictures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeung Sook; Yoon, Yup; Sung, Dong Yook; Choi, Woo Suk; Nam, Kyung Jin; Lim, Jae Hoon [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    1990-07-15

    The authors performed 27 fluoroscopically guided balloon dilatation in 12 patients of esophageal stricture during recent 3 years. The causes of esophageal stricture were corrosive esophagitis (N=2) and congenital narrowing (N=1), including postoperative narrowing in achalasia (N=3), esophageal varix (N=3), lye stricture (N=2) and esophageal cancer (N=1). Successful dilatation of the stricture was achieved during the procedure in 10 patients(83%). Major complication such as esophageal rupture was not found. The authors conclude that fluoroscopically guided esophageal balloon dilatation is a safe and effective method for treatment of symptomatic esophageal strictures.

  10. High altitude balloon experiments at IIA

    Science.gov (United States)

    Nayak, Akshata; Sreejith, A. G.; Safonova, Margarita; Murthy, Jayant

    Recent advances in balloon experiments as well as in electronics have made it possible to fly scientific payloads at costs accessible to university departments. We have begun a program of high altitude ballooning at the Indian Institute of Astrophysics, Bengaluru. The primary purpose of this activity is to test low-cost ultraviolet (UV) payloads for eventual space flight, but we will also try scientific exploration of the phenomena occurring in the upper atmosphere, including sprites and meteorite impacts. We present the results of the initial experiments carried out at the CREST campus of IIA, Hosakote, and describe our plans for the future.

  11. Performance of the EUSO-Balloon electronics

    Science.gov (United States)

    Barrillon, P.; Bacholle, S.; Bayer, J.; Blaksley, C.; Blin, S.; Cafagna, F.; Dagoret, S.; Fornaro, C.; Gorodetzky, P.; Jung, A.; Karczmarczyk, J.; De La Taille, C.; Medina Tanco, G.; Miyamoto, H.; Moretto, C.; Osteria, G.; Park, I.; Perfetto, F.; Prévôt, G.; Prat, P.; Rabanal Reina, J.; Rojas, J.; Santiago, L.; Scotti, V.; Silva, H.; Szabelski, J.

    2016-01-01

    The 24th of August 2014, the EUSO-Balloon instrument went for a night flight for several hours, 40 km above Timmins (Canada) balloon launching site, concretizing the hard work of an important part of the JEM-EUSO collaboration started 3 years before. This instrument consists of a telescope made of two lenses and a complex electronic chain divided in two main sub-systems: the PDM (Photo Detector Module) and the DP (Data Processor). Each of them is made of several innovative elements developed and tested in a short time. This paper presents their performances before and during the flight.

  12. Catalytic Generation of Lift Gases for Balloons

    Science.gov (United States)

    Zubrin, Robert; Berggren, Mark

    2011-01-01

    A lift-gas cracker (LGC) is an apparatus that generates a low-molecular-weight gas (mostly hydrogen with smaller amounts of carbon monoxide and/or carbon dioxide) at low gauge pressure by methanol reforming. LGCs are undergoing development for use as sources of buoyant gases for filling zero-gauge-pressure meteorological and scientific balloons in remote locations where heavy, high-pressure helium cylinders are not readily available. LGCs could also be used aboard large, zero-gauge-pressure, stratospheric research balloons to extend the duration of flight.

  13. Balloon dilatation of alimentary tract strictures

    International Nuclear Information System (INIS)

    From a series of balloon dilatations of alimentary tract strictures 11 patients with different types of gastric and oesophagogastric anastomotic stenoses are reported. The dilatation of gastric outflow tract obstructions was highly effective in the treatment of retention. In 7 out of 8 cases with gastric outflow stenosis surgery could be entirely avoided and replaced by balloon dilatation. The importance of eliminating retention in the healing of gastric ulcer is discussed. Fistulation in oesophagogastric anastomoses due to stenosis of the outflow portion was successfully treated. The importance of achieving a free outflow tract in order to prevent insufficiency of the anastomosis and formation of a fistula is stressed. (orig.)

  14. Particle Astrophysics in NASA's Long Duration Balloon Program

    International Nuclear Information System (INIS)

    A century after Viktor Hess' discovery of cosmic rays, balloon flights still play a central role in the investigation of cosmic rays over nearly their entire spectrum. We report on the current status of NASA balloon program for particle astrophysics, with particular emphasis on the very successful Antarctic long-duration balloon program, and new developments in the progress toward ultra-long duration balloons

  15. Plasma levels following application of paclitaxel-coated balloon catheters in patients with stenotic or occluded femoropopliteal arteries

    International Nuclear Information System (INIS)

    Purpose: Paclitaxel-coated balloon catheters inhibit restenosis after coronary and peripheral angioplasty (PCI,PTA). The aim of this study was to investigate paclitaxel plasma levels and laboratory parameters following PTA with paclitaxel-coated balloons (PCB) in peripheral arteries. Materials and Methods: This single treatment arm, multicenter study included 14 patients with Rutherford stage 1 - 5 with occlusions of up to 5 cm or ≥ 70 % diameter stenosis of the superficial femoral or popliteal arteries (SFA, PA). PTA was performed using up to three PCB catheters. The paclitaxel plasma levels and safety laboratory parameters were determined by collecting blood samples pre-intervention, immediately post-intervention, at 0.5, 1, 2, 4, 8, 24 hours and 1 and 4 weeks post-intervention (p. i.). Vital signs were monitored to assess clinical safety. Results: PTA was performed successfully in all patients. Paclitaxel plasma levels were always below a level and duration known to cause systemic side effects. A mean peak paclitaxel plasma level (40 ng/ml) was reached immediately p. i. and decreased rapidly below detectable levels in more than half of the patients already 2 hours p. i. The paclitaxel plasma concentrations returned to values below detectable levels at 24 hours p. i. in all patients. Laboratory parameters and vital signs did not give any reason for safety concerns. No adverse events associated with balloon coating were observed. Conclusion: The results of 14 patients with peripheral arterial occlusive disease show no systemic bioavailability of paclitaxel > 24 hours after PTA with one or more PCB catheters, indicating that the PCB catheter is safe with regard to possible systemic effects. (orig.)

  16. Endovascular treatment with angioplasty or stenting versus endarterectomy in patients with carotid artery stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): long-term follow-up of a randomised trial.

    LENUS (Irish Health Repository)

    Ederle, Jörg

    2009-10-01

    Endovascular treatment (angioplasty with or without stenting) is an alternative to carotid endarterectomy for carotid artery stenosis but there are scarce long-term efficacy data showing that it prevents stroke. We therefore report the long-term results of the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS).

  17. Increased Production of Sonic Hedgehog by Ballooned Hepatocytes

    OpenAIRE

    Rangwala, Fatima; Cynthia D Guy; Lu, Jiuyi; SUZUKI, Ayako; Burchette, James L.; Abdelmalek, Manal F; Chen, Wei; Diehl, Anna Mae

    2011-01-01

    Ballooned hepatocytes distinguish nonalcoholic steatohepatitis (NASH) from steatosis. Such cells contain dilated endoplasmic reticulum and ubiquitin aggregates, characteristics of endoplasmic reticulum stress. Hepatocyte ballooning increases risk for fibrosis in NASH, suggesting ballooned hepatocytes release pro-fibrogenic factors. Hedgehog ligands function as pro-fibrogenic factors in liver diseases, but mechanisms for Hedgehog ligand production remain poorly understood. We evaluated the hyp...

  18. Auditory Risk of Exploding Hydrogen-Oxygen Balloons

    Science.gov (United States)

    Gee, Kent L.; Vernon, Julia A.; Macedone, Jeffrey H.

    2010-01-01

    Although hydrogen-oxygen balloon explosions are popular demonstrations, the acoustic impulse created poses a hearing damage risk if the peak level exceeds 140 dB at the listener's ear. The results of acoustical measurements of hydrogen-oxygen balloons of varying volume and oxygen content are described. It is shown that hydrogen balloons may be…

  19. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine...

  20. Adjuvant revascularization of intracranial artery occlusion with angioplasty and/or stenting

    International Nuclear Information System (INIS)

    In conjunction with intravenous and/or intra-arterial thrombolysis, adjuvant revascularization of intracranial artery occlusion by angioplasty vs. stenting remains controversial. We evaluated outcome in patients with intracranial occlusion after angioplasty and/or stenting. Thirty-three patients who underwent angioplasty or stenting (17 stenting and 16 angioplasty) for intracranial arterial occlusion during the past 5 years were enrolled from prospective neurointerventional database. We compared recanalization rate [defined as thrombolysis in myocardial infarction (TIMI) grade II/III flow], adverse events, and clinical outcome [modified Rankin scale (mRS) at 1 and 6 months]. We also tried to determine independent variables associated with clinical outcome. Median initial National Institutes of Health Stroke Scale (NIHSS) was 13 and median time to treatment was 12 h from symptom onset. The successful recanalization rate was mean 79%. Symptomatic hemorrhage occurred in 15% (5/33). Events (27%, 9/33) at 1 month included four deaths, four major, and one minor stroke. Good outcome (mRS ≤ 2) was achieved in 17 patients (52%) at 6 months and was significantly related to age, initial NIHSS, TIMI flow, and stenting on bivariate analysis. On multivariable analysis, stenting was the only variable significantly associated with a 6-month, good clinical outcome (OR, 14.48; 95% CI, 1.76 to 118.93; p = 0.013) Intracranial revascularization with angioplasty and/or stenting may improve the clinical outcome in selected patients with intracranial occlusion. Multiple factors are related to favorable clinical outcome. (orig.)

  1. Short-term outcome of stent-assisted angioplasty for extracranial carotid stenosis

    International Nuclear Information System (INIS)

    Objective: To evaluate the safety and short-term outcome of stent-assisted angioplasty for extracranial carotid stenosis. Methods: From October 2000 to September 2002, 93 cases of extracranial carotid stenosis, including 86 cases of carotid bifurcation stenosis, 4 of extracranial internal carotid stenosis, 2 of common carotid stenosis and 1 of functional external carotid stenosis, were treated by self-expandable stent placement and angioplasty. Results: Stent placement and angioplasty were successfully administered in all the 93 patients. The average stenosis rate was reduced from (79.5 ± 14.6)% before treatment to (11.2 ± 7.8)% after stent-assisted angioplasty. There were only 1 case of TIA (1.1%) and 1 case of minor stroke (1.1%) during the operation, without mortality or major stroke. No cerebral ischemic attach occurred in the 91 patients during clinical follow up for a period of 3-25 months with an average of 7.9 months. twenty-nine patients were angiographically followed up 6 months after treatment with only one asymptomatic restenosis (3.4%). Conclusions: Endovascular stent-assisted angioplasty for extracranial stenosis is safe and effective with considerable good short-term outcome

  2. Effect of percutaneous transluminal coronary angioplasty on coronary reserve

    International Nuclear Information System (INIS)

    This study was done to assess the effect of percutaneous transluminal coronary angioplasty (PTCA) on regional myocardial perfusion (RMP) in the region distal to a stenosis in 48 patients. Quantitative RMP in ml/100g/min was measured from the washout of Xe-133 following selective injection into the involved coronary artery. After successful dilation, determined by a reduction in %stenosis to a ≤ 50% lesion and in pressure gradient across the lesion, the RMP measurement was repeated. In these patients, means %stenosis was 85% pre PTCA and 29% post PTCA with mean pressure gradient of 60 Hg pre PTCA and 21 mm Hg post PTCA. 21 of these 48 patients also had RMP measured after isoproterenol (ISO) both pre and post PTCA to increase myocardial oxygen demand to assess coronary reserve. Heart rate (HR) and systolic blood pressure (SBP) were constant pre and post PTCA which allowed a valid comparison. The results are presented. A group of 13 patients with normal coronary arteries and ventricular function showed a mean control RMP of 78 +- 15 and a mean ISO RMP of 140 +- 26. The data demonstrate that following successful PTCA quantitative RMP improves both at rest and with an ISO challenge and is similar to RMP in normal coronary arteries

  3. New fiber-optic tip for laser angioplasty

    International Nuclear Information System (INIS)

    A class of fiber tip radiating laser light mainly along a cone coaxial to the fiber has been extensively studied in the past few years, and tests have been carried out, for example, in gastroentherology to remove occluding cancers. Their interest in treating obstructions in blood vessels or bronchos is also well known. In practice, however, these fiber tips consisting of cones or truncated cones are not safe in medical applications, in particular, in endoscopy. The cones indeed still radiate a non-negligible part of the light on-axis, particularly in the case of truncated cones. In these cases, the wall of vessels or other cavities can be damaged. Moreover, the conical tips can easily break. Recently more study sapphire tips have become available, but their size frequently does not fit the vessel lumen while the high refractive index results in a different optical behavior with respect to quartz cone tips. For these reasons a new probe has been studied, particularly for laser angioplasty, consisting of a cone fiber tip inserted in a quartz microcapsule. This capsule is sealed on the top by a toroidal-shaped lens structure, which avoids the on-axis radiation and gives rise to a sharp corolla-shaped beam. A typical overall radiation diagram shows a dark central cone with half-aperture of 30-450, depending on the aperture of the cone tip, surrounded by a bright crown with uniform intensity

  4. Primary coronary angioplasty in 9,434 patients during acute myocardial infarction: predictors of major in- hospital adverse events from 1996 to 2000 in Brazil

    Directory of Open Access Journals (Sweden)

    Mattos Luiz Alberto

    2002-01-01

    Full Text Available OBJECTIVE: To verify the results after the performance of primary coronary angioplasty in Brazil in the last 4 years. METHODS: During the first 24 hours of acute myocardial infarction onset, 9,434 (12.2% patients underwent primary PTCA. We analyzed the success and occurrence of major in-hospital events, comparing them over the 4-year period. RESULTS: Primary PTCA use increased compared with that of all percutaneous interventions (1996=10.6% vs. 2000=13.1%; p<0.001. Coronary stent implantation increased (1996=20% vs. 2000=71.9%; p<0.001. Success was greater (1998=89.5% vs. 1999=92.5%; p<0.001. Reinfarction decreased (1998=3.9% vs. 99=2.4% vs. 2000=1.5%; p<0.001 as did emergency bypass surgery (1996=0.5% vs. 2000=0.2%; p=0.01. In-hospital deaths remained unchanged (1996=5.7% vs. 2000=5.1%, p=0.53. Balloon PTCA was one of the independent predictors of a higher rate of unsuccessful procedures (odds ratio 12.01 [CI=95%] 1.58-22.94, and stent implantation of lower mortality rates (odds ratio 4.62 [CI=95%] 3.19-6.08. CONCLUSION: The success rate has become progressively higher with a significant reduction in reinfarction and urgent bypass surgery, but in-hospital death remains nearly unchanged. Coronary stenting was a predictor of a lower death rate, and balloon PTCA was associated with greater procedural failure.

  5. Einfluß unterschiedlicher klinischer und anamnestischer Parameter auf die Erfolgsaussichten der perkutanen transluminalen renalen Angioplastie : eine retrospektive Studie

    OpenAIRE

    Bröhr, Marlon Andreas Paul

    2002-01-01

    Between 1993 and 1998 171 patients had a percutaneous transluminal angioplasty of the renal artery. It was examinated in which way different clinal and anamnestic parameters (sex, age, nicotin-abusus, use of stens, pathogenesis of the stenosis) did influence the long-time results of percutaneous transluminal angioplasty of the renal artery.

  6. Space and Earth Observations from Stratospheric Balloons

    Science.gov (United States)

    Peterzen, Steven; Ubertini, Pietro; Masi, Silvia; Ibba, Roberto; Ivano, Musso; Cardillo, Andrea; Romeo, Giovanni; Dragøy, Petter; Spoto, Domenico

    Stratospheric balloons are rapidly becoming the vehicle of choice for near space investigations and earth observations by a variety of science disciplines. With the ever increasing research into climatic change, instruments suspended from stratospheric balloons offer the science team a unique, stable and reusable platform that can circle the Earth in the polar region or equatorial zone for thirty days or more. The Italian Space Agency (ASI) in collaboration with Andoya Rocket Range (Andenes, Norway) has opened access in the far northern latitudes above 78o N from Longyearbyen, Svalbard. In 2006 the first Italian UltraLite Long Duration Balloon was launched from Baia Terra Nova, Mario Zuchelli station in Antarctica and now ASI is setting up for the their first equatorial stratospheric launch from their satellite receiving station and rocket launch site in Malindi, Kenya. For the equatorial missions we have analysed the statistical properties of trajectories considering the biennal oscillation and the seasonal effects of the stratospheric winds. Maintaining these launch sites offer the science community 3 point world coverage for heavy lift balloons as well as the rapidly deployed Ultralight payloads and TM system ASI developed to use for test platforms, micro experiments, as well as a comprehensive student pilot program

  7. The effect of ballooning model in ISAAC

    International Nuclear Information System (INIS)

    The purpose of this paper is to analyze the ballooning effect in the fuel channel with the ISAAC (Integrated Severe Accident Analysis code for CANDU Plants) computer code which was developed for the severe accident analysis at CANDU plants. Cladding/PT ballooning model parameter in the ISAAC code is used to analyze its effect mainly on the hydrogen production from the fuel channel. According to the current ISAAC version, cladding failure occurs when the cladding temperature exceeds a user-specified failure temperature, resulting in a fission products release from the fuel rod to the primary system. The typical accident sequences of a loss of feed water (LOFW) and a large LOCA (LLOCA) scenario are selected. Unlike the PWRs, the ballooning effect in CANDU plants is not so clear during the low pressure sequences. Instead, pressure tube ballooning during the high pressure sequences decreases the amount of hydrogen generated from the fuel when pressure tube-calandria tube contact occurs, resulting in a cladding and pressure tube temperature decrease. (authors)

  8. Treatment of tuberculous bronchostenosis: balloon bronchoplasty

    International Nuclear Information System (INIS)

    The purpose of this study is to evaluate the efficacy of the balloon bronchoplasty in the treatment of the tuberculous bronchostenosis. Balloon bronchoplasty was performed in thirteen patients with stenosis of the left main bronchus (two with combined left upper and lower lobar bronchostenosis) using a inflatable balloon catheter under a fluoroscopic guide. We analysed the changes in the severity of dyspnea and wheezing, serial FEV1/FVC as a parameter of the airflow obstruction, and bronchial diameter and lung volume on chest radiographs. The extent of pulmonary tuberculosis was correlated with the improvement of FEV1/ FVC. There was an improvement of dyspnea in 69% (9/13), decrease of wheezing in 69% (9/13), significant increase of FEV1/FVC in 18% (2/11). The increase of the bronchial diameter and lung volume were seen in 84% (11/13) and 53% (7/13), respectively. The significant increase of FEV1/FVC was seen in 28% (2/7) of the patients with lung involvement of tuberculous less than one third of left upper lobe, whereas there was no increase in those of more than one third. The was no complication except transient leukocytosis, fever and blood-tinged sputum. In conclusion, balloon bronchoplasty is effective in the treatment of medically intractable tuberculous bronchostenosis, and can be considered as an initial method of treatment

  9. A case of balloon rupture during insertion of an intragastric balloon for treatment of morbid obesity

    OpenAIRE

    Bor, Serhat; TURAN, İlker; ÖZÜTEMİZ, Ömer

    2007-01-01

    The therapeutic options for treatment of morbid obesity are diet, exercise, behavioral modifications, medical treatment and bariatric surgery. An alternative approach to surgery is the endoscopic placement in the stomach of balloons which are filled with liquid, providing a sensation of fullness that decreases food consumption. The rate of complications associated with the placement of intragastric balloons is low. A significant late complication is deflation and/or displacement of the...

  10. Stratospheric Balloon Platforms for Near Space Access

    Science.gov (United States)

    Dewey, R. G.

    2012-12-01

    For over five decades, high altitude aerospace balloon platforms have provided a unique vantage point for space and geophysical research by exposing scientific instrument packages and experiments to space-like conditions above 99% of Earth's atmosphere. Reaching altitudes in excess of 30 km for durations ranging from hours to weeks, high altitude balloons offer longer flight durations than both traditional sounding rockets and emerging suborbital reusable launch vehicles. For instruments and experiments requiring access to high altitudes, engineered balloon systems provide a timely, responsive, flexible, and cost-effective vehicle for reaching near space conditions. Moreover, high altitude balloon platforms serve as an early means of testing and validating hardware bound for suborbital or orbital space without imposing space vehicle qualifications and certification requirements on hardware in development. From float altitudes above 30 km visible obscuration of the sky is greatly reduced and telescopes and other sensors function in an orbit-like environment, but in 1g. Down-facing sensors can take long-exposure atmospheric measurements and images of Earth's surface from oblique and nadir perspectives. Payload support subsystems such as telemetry equipment and command, control, and communication (C3) interfaces can also be tested and operationally verified in this space-analog environment. For scientific payloads requiring over-flight of specific areas of interests, such as an active volcano or forest region, advanced mission planning software allows flight trajectories to be accurately modeled. Using both line-of-sight and satellite-based communication systems, payloads can be tracked and controlled throughout the entire mission duration. Under NASA's Flight Opportunities Program, NSC can provide a range of high altitude flight options to support space and geophysical research: High Altitude Shuttle System (HASS) - A balloon-borne semi-autonomous glider carries

  11. Intracoronary radionuclide therapy with liquid 188Re-filled balloons: Radiopharmaceutical and dosimetric studies

    International Nuclear Information System (INIS)

    Full text: Percutaneous transluminal coronary angioplasty (PCTA) associated with radioactive liquid-filled balloons has demostrated useful to inhibit the growth of neointimal tissue and as consequence offers a potential method to decrease restenosis rate. Near 40 to 60% of the patients suffered from restenosis, being necessary to reiterate angioplasty. The spectrum of late effects from the variety of sources types, dosimetric aspects and delivery systems has not became clear. An attractive radionucleid for this purpose is 188Re, that is eluated from a 188W/188Re generator. The generator can be used during 6 months, depending on the initial activity. The specific activity can be increased by a concentration system up to a maximum of 20 GBq/mL. The present study had the purpose of optimizing the relation risk/benefit during a procedure of brachytherapy with 188Re associated to angioplasty. The possibility of balloon rupture exists, with the passage of the radioactive solution towards the patient bloodstream. In order to increase the security during the treatment the evaluation of different agents such as 188Re- DTPA, 188Re-Citrate and 188Re-EC vs 188ReO4- (as the standard agent) was performed. Labelling procedures were optimized considering pH, temperature, reaction time and carrier adition. Dosimetric studies using Mirdose 3, after iv injection to Wistar rats of the three radiopharmaceuticals were performed. Biodistrubion at 1 and 3 hs post-administration and dose estimation showed no difference between all the radiopharmaceuticals, presenting low uptake in thyroid and stomach, and faster renal elimination than 188ReO4-, with smaller residence times in all the organs. As the preparation of 188Re-Citrate and 188Re-EC required less strong conditions than 188Re-DTPA, one of these radiopharmaceuticals could be selected to improve the security of the procedure. A second point of this study was the evaluation of a number of safety requirements in order to estimate

  12. NASA balloon design and flight - Philosophy and criteria

    Science.gov (United States)

    Smith, I. S., Jr.

    1993-01-01

    The NASA philosophy and criteria for the design and flight of scientific balloons are set forth and discussed. The thickness of balloon films is standardized at 20.3 microns to isolate potential film problems, and design equations are given for specific balloon parameters. Expressions are given for: flight-stress index, total required thickness, cap length, load-tape rating, and venting-duct area. The balloon design criteria were used in the design of scientific balloons under NASA auspices since 1986, and the resulting designs are shown to be 95 percent effective. These results represent a significant increase in the effectiveness of the balloons and therefore indicate that the design criteria are valuable. The criteria are applicable to four balloon volume classes in combination with seven payload ranges.

  13. Measurements of gondola motion on a stratospheric balloon flight

    CERN Document Server

    Safonova, Margarita; Sreejith, A G; Sarpotdar, Mayuresh; Ambily, S; Prakash, Ajin; Mathew, Joice; Murthy, Jayant; Anand, Devarajan; Kapardhi, B V N; Kumar, B Suneel; Kulkarni, P M

    2016-01-01

    Balloon experiments are an economically feasible method of conducting observations in astronomy that are not possible from the ground. The astronomical payload may include a telescope, a detector, and a pointing/stabilization system. Determining the attitude of the payload is of primary importance in such applications, to accurately point the detector/telescope to the desired direction. This is especially important in generally unstable lightweight balloon flights. However, the conditions at float altitudes, which can be reached by zero pressure balloons, could be more stable, enabling accurate pointings. We have used the Inertial Measurement Unit (IMU), placed on a stratospheric zero pressure balloon, to observe 3-axis motion of a balloon payload over a fight time of 4.5 hours, from launch to the float altitude of 31.2 km. The balloon was launched under nominal atmospheric conditions on May 8th 2016, from a Tata Institute of Fundamental Research Balloon Facility, Hyderabad.

  14. Gadopentetate dimeglumine as a contrast agent in peripheral angioplasty. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, J.M.; Smiddy, P.; Molloy, M.P. [St. Jame`s Hospital, Dublin (Ireland). Dept. of Diagnostic Imaging; O`Hare, N.J. [St. Jame`s Hospital, Dublin (Ireland). Dept. of Medical Physics

    1998-09-01

    Gadopentetate dimeglumine (Gd-DTPA) is widely used as a contrast agent in MR imaging. We report on a case in which Gd-DTPA was used as the contrast agent during angioplasty in a patient who had recently had an adverse reaction to a non-ionic iodinated contrast medium. Gd-DTPA allowed a diagnostic angiogram to be performed with no side effects, and may thus be a useful contrast agent at angioplasty in patients with contra-indications to iodinated contrast media. (orig.)

  15. Medical angioplasty - Hope and expectations: An optimistic overview

    Directory of Open Access Journals (Sweden)

    Mohammed F Abdul-Mohsen

    2011-01-01

    Full Text Available Primary and secondary prevention of cardiovascular diseases (CVD are markedly overlooked worldwide. The use of these kinds of preventive methods will greatly improve outcome of or even reverse major CVD, especially coronary atherosclerosis. Comprehensive lifestyle changes combined with aggressive medical therapy [lipid lowering agents "statins", antiplatelet agents, beta-blockers and angiotensin-converting enzyme inhibitors] for patients suffering from coronary heart disease significantly reduce all major adverse cardiovascular events (MACE, especially in those with stable coronary artery disease (CAD, even if their coronary lesions are significant. The main mechanistic pathways for the significant reduction of MACE are: Stabilization of atheromatous plaques through endothelial function reparation, strengthening of the fibrous cap of the atheromatous plaque and reduction of atheroma burden, i.e., reversal of the process of coronary artery stenosis, the great dream of "medical angioplasty". Despite the compelling data indicating the great beneficial effects of both primary and secondary prevention of coronary atherosclerosis, the US national survey data reveals that only a minority of patients eligible by guidelines for these therapies in fact receive them. Hence, we strongly believe that our main duties as cardiologists is to improve the up-to-date knowledge of the practicing physicians about utility of aggressive medical therapy for both prevention and reversal of CVD, and also to promote useful primary and secondary prevention programs among physicians and patients. Meanwhile, further improvement and refinement of the current therapeutic modalities and introduction of new modalities for the management of lipid parameters other than LDL-C, such as HDL-C, triglyceride, lipoprotein (a, LDL particle size and susceptibility to oxidation may add further favourable effects in prevention and reversal of atherosclerotic process. Cardiologists should be

  16. [Exercise tolerance in patients after successful percutaneous transluminal coronary angioplasty].

    Science.gov (United States)

    Tsumoto, S; Nakagawa, Y; Asakuma, S; Naruse, H; Komasa, N; Ohyanagi, M; Tateishi, J; Yasutomi, N; Fujitani, K; Iwasaki, T

    1991-01-01

    In 32 patients with successful percutaneous transluminal coronary angioplasty (PTCA), we performed treadmill exercise tests (TMET) before and about one month after PTCA to assess the correlation between the improvement in coronary artery lesions and exercise tolerance. Either the Bruce protocol (B: n = 12) or the modified Bruce protocol (MB: n = 20) was used; with the latter being applied to patients whose cardiac function seemed depressed. In 15 patients, oxygen consumption (VO2) was measured by analyzing the expired gases, 13 patients underwent exercise thallium-201 myocardial perfusion scintigraphy before and after PTCA, whose results were compared with those of TMET. In both B and MB protocols, the treadmill walking time was significantly prolonged after PTCA, compared to that before PTCA (B: 7.4 +/- 1.3 vs 9.5 +/- 1.9, MB: 11.4 +/- 3.5 vs 12.7 +/- 3.5 min). Heart rates (HR) and rate pressure products (RPP) were significantly increased after PTCA in both protocols (HR B: 139 +/- 18 vs 154 +/- 17, MB: 121 +/- 20 vs 137 +/- 19 bpm, RPP B: 26,500 +/- 5,600 vs 30,300 +/- 6,700, MB: 19,400 +/- 6,200 vs 22,700 +/- 6,600 mmHg.bpm), however, systolic blood pressure did not change significantly after PTCA in either protocol. While there was a significant improvement in VO2 after PTCA (21.6 +/- 6.3 vs 25.7 +/- 4.2 ml/kg/min), the O2-pulse remained unchanged. Thallium-201 myocardial scintigraphy revealed improvement of myocardial perfusion in 8 of the 13 cases examined.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1841916

  17. Prediction of Prolonged Hemodynamic Instability During Carotid Angioplasty and Stenting

    Science.gov (United States)

    Rhim, Jong Kook; Park, Jeong Jin; Choi, Hyuk Jai; Cho, Young Dae; Sheen, Seung Hun; Jang, Kyung-Sool

    2016-01-01

    Purpose The aim of this study was to assess the risk factors of prolonged hemodynamic instability (HDI) after carotid angioplasty and stenting (CAS). Herein, a simplified predictive scoring system for prolonged HDI is proposed. Materials and Methods Sixty-six patients who had CAS from 2011 to 2016 at a single institution were evaluated. Prolonged HDI was defined as systolic blood pressure >160 mm Hg or <90 mm Hg or heart rate <50 beats/min, lasting over 30 minutes despite medical treatments. For the study, clinical data and radiologic data, including plaque morphology and stenosis were analyzed. Results Prolonged HDI was observed in 21 patients (31.8%). Multivariable analysis revealed that calcification (OR, 6.726; p=0.006), eccentric stenosis (OR, 3.645; p=0.047) and extensive plaque distribution (OR, 7.169; p=0.006) were related to prolonged HDI. According to these results, a simplified scoring scale was proposed based on the summation of points: 2 points for calcified plaque, 2 points for extensive plaque distribution, and 1 point for eccentric stenosis. The percentages of prolonged HDI according to the total score were as follows: score 0, 8.7%; score 1, 20.0%; score 2, 38.5%; score 3, 72.7%; score 4, 66.7%; score 5, 100%. From the analysis, the total score in patients with prolonged HDI was significantly higher than those without prolonged HDI (p<0.001). Conclusion Prolonged HDI can be associated with calcification of plaque, eccentric stenosis and extensive plaque distribution, and a simplified scoring system enables prediction of prolonged HDI according to our cohort.

  18. Sonic Thermometer for High-Altitude Balloons

    Science.gov (United States)

    Bognar, John

    2012-01-01

    The sonic thermometer is a specialized application of well-known sonic anemometer technology. Adaptations have been made to the circuit, including the addition of supporting sensors, which enable its use in the high-altitude environment and in non-air gas mixtures. There is a need to measure gas temperatures inside and outside of superpressure balloons that are flown at high altitudes. These measurements will allow the performance of the balloon to be modeled more accurately, leading to better flight performance. Small thermistors (solid-state temperature sensors) have been used for this general purpose, and for temperature measurements on radiosondes. A disadvantage to thermistors and other physical (as distinct from sonic) temperature sensors is that they are subject to solar heating errors when they are exposed to the Sun, and this leads to issues with their use in a very high-altitude environment

  19. Pneumothorax, music and balloons: A case series

    OpenAIRE

    2013-01-01

    We describe two cases of spontaneous pneumothorax in young healthy adults with no underlying structural lung disease. The onset of pneumothorax was following physical activity including playing musical instruments and blowing of balloons. There is sparse data evaluating the pathophysiology of primary spontaneous pneumothorax in relation to increased mouth pressures. These cases highlight the possible physical effect of valsalva manoeuvre on transpulmonary pressures, and the potential risk of ...

  20. A Balloon-Gondola Dedicated for Waterlanding

    Science.gov (United States)

    Evrard, J.; Roudil, G.; Catalano, C.; Von Ballmoos, P.

    2015-09-01

    As balloon flights over populated areas are increasingly considered a safety risk, new launch sites are chosen to ensure that sparsely inhabited regions are overflown. Particular vigilance is requested for the selection of the zones where flight termination and landing take place. While open sea would ideally fulfil the safety requirements for flight track and termination, traditional balloon experiments are lost or severely damaged on water landings. EUSO-Balloon, a pathfinder mission for Cosmic-Ray physics, has deliberately been designed as a water-landing gondola as the instrument eventually will observe Energetic Air Showers above open water. In order to maximize the chances for a dry recovery of all the sensitive equipment after a water-landing, the gondola features a number of special devices: inside a watertight capsule using a Fresnel lens as a porthole, the electronics is mounted on a ‘dry-shelf' with limber holes (drain holes). Also, the entire capsule is held above the waterline by a collar of floaters. To minimize damage to the payload and warrant the integrity of the leak-tight capsule at splashdown, efficient deceleration is achieved by using the instruments optical baffle (nadir-pointing) as a cylinder; the pressure of the air-cushion in the enclosed volume being passively controlled by calibrated evacuation-holes. Upon its maiden flight of August 25, 2014 from Timmins, Ontario, EUSO-Balloon not only accomplished its science goals, but it also accidentally landed in a small lake, validating the water-landing capacity it was designed for.

  1. Lightweight Reusable Solar Array For Balloons

    Science.gov (United States)

    Aaron, K.; Tensor, P.; Nock, K.; Wyszkowski, C.

    We will discuss a new lightweight reusable solar array system, dubbed HighPower, which is being developed for the Ultra-Long Duration Balloon (ULDB) program using NASA/SBIR funding, but which is also applicable to other balloon systems. The system uses a vertically deployed stack of panels suspended from their corners by cables. The stack act likes a two-dimensional Venetian blind. By raising and lowering opposite corners, the array of parallel panels can be pointed over most of the upper hemisphere. This allows the panels to remain normal to the sun despite the slow rotation of the gondola and without requiring rotation of the system (no slip rings) or heavy cantilevered rotation joints. The system is sized to generate 2000 W using six 2m x 2m panels. The modularity of the system allows panels to be added or removed to tailored the power to the needs of the mission. Prior to cut -down of the balloon, the panels can be retracted and stowed compactly in the lower part of the gondola. This will protect the array during landing, allowing the array to be reused on subsequent flights.

  2. Long Duration Balloon Charge Controller Stack Integration

    Science.gov (United States)

    Clifford, Kyle

    NASA and the Columbia Scientific Balloon Facility are interested in updating the design of the charge controller on their long duration balloon (LDB) in order to enable the charge controllers to be directly interfaced via RS232 serial communication by a ground testing computers and the balloon's flight computer without the need to have an external electronics stack. The design involves creating a board that will interface with the existing boards in the charge controller in order to receive telemetry from and send commands to those boards, and interface with a computer through serial communication. The inputs to the board are digital status inputs indicating things like whether the photovoltaic panels are connected or disconnected; and analog inputs with information such as the battery voltage and temperature. The outputs of the board are 100ms duration command pulses that will switch relays that do things like connect the photovoltaic panels. The main component of this design is a PIC microcontroller which translates the outputs of the existing charge controller into serial data when interrogated by a ground testing or flight computer. Other components involved in the design are an AD7888 12-bit analog to digital converter, a MAX3232 serial transceiver, various other ICs, capacitors, resistors, and connectors.

  3. MAXIS Balloon Observations of Electron Microburst Precipitation

    Science.gov (United States)

    Millan, R. M.; Hunter, A. E.; McCarthy, M. P.; Lin, R. P.; Smith, D. M.

    2003-12-01

    Quantifying and understanding losses is an integral part of understanding relativistic electron variability in the radiation belts. SAMPEX observations indicate that electron microburst precipitation is a major loss mechanism during active periods; the loss of relativistic electrons during a six hour period due to microburst precipitation was recently estimated to be comparable to the total number of trapped electrons in the outer zone (Lorentzen et al., 2001). Microburst precipitation was first observed from a balloon (Anderson and Milton, 1964), but these early measurements were only sensitive to MAXIS 2000 long duration balloon campaign. MAXIS was launched from McMurdo Station in Antarctica carrying a germanium spectrometer, a BGO scintillator and two X-ray imagers designed to measure the bremsstrahlung produced by precipitating electrons. The balloon circumnavigated the south pole in 18 days covering magnetic latitudes ranging from 58o-90o South. During the week following a moderate geomagnetic storm (with Dst reaching -91 nT), MAXIS detected a total of over 16 hours of microburst precipitation. We present high resolution spectra obtained with the MAXIS germanium spectrometer which allow us to determine the precipitating electron energy distribution. The precipitating distribution will then be compared to the trapped distribution measured by the GPS and LANL satellites. We also examine the spatial distribution of the precipitation.

  4. Subintimal angioplasty for the treatment of long segment occlusion of superficial femoral artery: the midterm results

    International Nuclear Information System (INIS)

    Objective: To discuss the clinical value of subintimal angioplasty in treating long segment occlusion of superficial femoral artery and to observe its midterm results. Methods: Subintimal angioplasty was performed in 45 patients with long segment occlusion of superficial femoral artery, whose clinical presentation was intermittent claudication or critical limb ischemia. The primary patency, limb salvage and factors influencing long-term patency were observed, and the clinical data were analyzed. Results: Of the total 45 cases, the subintimal angioplasty was successfully accomplished in 43. The success rate of antegrade approach technique via the superficial femoral artery was 80% (n=36), the occlusion was recanalized by using retrograde approach technique via ipsilateral popliteal artery in 7 case. The total technical success rate was 95.6%. The primary patency in 43 successful cases at 6, 12, 24 and 36 months was 85.7%, 69.0% 57.3% and 50.9%, respectively. No statistically significant difference in primary patency existed between the group of intermittent claudication and the group of critical limb ischemia (P>0.05). Statistically significant prediction factors for primary patency included the number of the run off vessels below the knee and the length of the occlusion (P<0.05). Conclusion: Subintimal angioplasty is an effective procedure for the treatment of long segment occlusions of superficial femoral artery with satisfactory mid-term results. (authors)

  5. HEMOPERFUSION DURING CORONARY ANGIOPLASTY - 1ST EUROPEAN EXPERIENCE WITH A NEW HEMOPERFUSION PUMP

    NARCIS (Netherlands)

    DEMUINCK, ED; MEEDER, J; MAGIELSE, C; BOM, VJJ; VANDIJK, RB; VERKERKE, GJ; LIE, KI

    1994-01-01

    Hemolysis tests with fresh human blood were performed in vitro with a new 5 ml, piston-type hemoperfusion pump, designed to prevent myocardial ischemia during coronary angioplasty. Despite driving pressures greater than 3 atmospheres, shear stress greater than 200 Pa, turbulent pump flow, and the pr

  6. Implication of Laser Technology Than That of Shape Memory Alloy [NiTinol] in Angioplasty

    Directory of Open Access Journals (Sweden)

    C. Anil Kumar

    2009-11-01

    Full Text Available Modern Angioplasty is an alternative to bypass heart surgery because of safety and validity. As we know that the Heart diseases has risen to become that number of deaths in most of the developing or developed countries due to the high increase rates of obesity, drug dependence, and diabetes. Stents are used throughout the body but the most critical area being coronary arteries. Convention Material like Stainless Steel 316LN is used before, now a day’s Smart Materials like Nitinol is having wider application in Angioplasty. This paper presents the comparison and limitations of the Shape memory alloy [Nitinol] technology with that of Laser technology. The several materials used in angioplasty for stenting are Stainless steel 316LN, Titanium and Nitinol. Laser technology finds more beneficial due to its rapid growth in technology and also more advantageous because of the alloys used are resistant to corrosion, yet the corrosion occurs when two dissimilar surfaces are in contact and this happens in almost all alloys These devices have been used for only a few years and, although initial results look promising, long-term effects have not been fully investigated. It's important to note that, if restenosis recur there is no good method to simply remove the blockage, and follow-up treatments may require laser surgery or localized drug delivery using other angioplasty devices.

  7. Assessment of percutaneous transluminal coronary angioplasty by quantitative coronary angiography: diameter versus densitometric area measurements

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); J.H.C. Reiber (Johan); W. Wijns (William); M.J.B.M. van den Brand (Marcel); C.J. Kooijman; H.J. ten Katen (Harald); P.G. Hugenholtz (Paul)

    1984-01-01

    textabstractCineangiograms of 138 patients who underwent percutaneous transluminal coronary angioplasty (PTCA) were analyzed with a computer-based coronary angiography analysis system. The results before and after dilatation are presented. In a first study group (120 patients), the severity of the o

  8. Quantitative evaluation of cerebral blood flow by XeCT in stenting angioplasty for carotid artery

    International Nuclear Information System (INIS)

    Objective: To evaluate the hemodynamic characteristics of severe carotid artery stenosis and curative effect of stent angioplasty through XeCT. Methods: From April 2006 to November 2006, 13 patients with severe carotid artery stenoses underwent stent angioplasty in our hospital, including 11 male and 2 females, in an average age of 57.31 ± 6.12. All patients underwent XeCT examination to evaluate the quantitative cerebral blood flow (CBF). The ischemic cortex is categorized into 4 kinds, the normal region, oligemia area, reversible ischemic site and ischemic core center. Measurement and comparison of the changes were taken before and after the therapy. Results: Preoperative XeCT revealed different decrease of CBF in the ipsilateral cortex, especially in MCA distributing territory. Ischemic areas reduced significantly after the stenting angioplasty. Oligemia area reduced from 32.63% to 14.22%. Reversible ischemic area reduced from 13.54% to 8.38%. Normal area increased from 47.51% to 71.13%. But ischemic core center showed no significant changes. Conclusions: XeCT is beneficial for evaluation of the hemodynamic characteristics of carotid artery stenoses and also for accurately demonstrating the curative effects of the stent angioplasty. (authors)

  9. Short- and long-term functional effects of percutaneous transluminal angioplasty in hemodialysis vascular access

    NARCIS (Netherlands)

    Van der Linden, J; Smits, JHM; Wolterbeek, DW; Zijlstra, JJ; De Jong, GHT; Van den Dorpel, MA; Blankestijn, PJ

    2002-01-01

    The efficacy of percutaneous transluminal angioplasty (PTA) is usually expressed as the angiographic result. Access flow (Qa) measurements offer a means to quantify the functional effects. This study was performed to evaluate the short-term functional and angiographic effects of PTA and to determine

  10. Five-year follow-up of angiographic disease progression after medicine, angioplasty, or surgery

    OpenAIRE

    Oliveira Sergio A; Stolf Noedir A; Góis Aécio FT; Soares Paulo R; Lopes Neuza; Borges Jorge; Hueb Whady A.; Ramires Jose AF

    2010-01-01

    Abstract Background Progression of atherosclerosis in coronary artery disease is observed through consecutive angiograms. Prognosis of this progression in patients randomized to different treatments has not been established. This study compared progression of coronary artery disease in native coronary arteries in patients undergoing surgery, angioplasty, or medical treatment. Methods Patients (611) with stable multivessel coronary artery disease and preserved ventricular function were randoml...

  11. Iliac artery myointimal hyperplasia in rabbits submitted to angioplasty and treated with Moringa oleifera

    Directory of Open Access Journals (Sweden)

    Jânio Cipriano Rolim

    2016-02-01

    Full Text Available Objective: to assess post-angioplasty myointimal hyperplasia in iliac artery of rabbits treated with extract of Moringa oleifera leaves. Methods : we conducted a randomized trial in laboratory animals for five weeks of follow-up, developed in the Vivarium of Pharmaceutical Technology Laboratory of the Universidade Federal da Paraíba. We used rabbits from the New Zealand breed, subjected to a hypercholesterolemic diet and angioplasty of the external iliac artery, randomized into two groups: M200 Group (n=10 - rabbits treated with 200mg/kg/day of Moringa oleifera leaves extract orally; SF group (n=10 - rabbits treated with 0.9% saline orally. After five weeks, the animals were euthanized and the iliac arteries prepared for histology. Histological sections were analyzed by digital morphometry. Statistical analysis was performed using the Student's t test. The significance level was 0.05. Results : there was no significant difference in myointimal hyperplasia between M200 and SF groups when comparing the iliac arteries submitted to angioplasty. Conclusion : there was no difference of myointimal hyperplasia between groups treated with saline and Moringa oleifera after angioplasty.

  12. High-fidelity translesional pressure gradients during percutaneous transluminal coroanry angioplasty: correlation with quantitative coronary angiography

    NARCIS (Netherlands)

    C. Lamm; M. Dohnal; P.W.J.C. Serruys (Patrick); H.U. Emanuelsson (Hakan)

    1993-01-01

    textabstractA fiberoptic pressure sensor mounted on an 0.018-inch guidewire (Pressure Guide) was used to measure the transstenotic pressure gradient in 30 patients undergoing percutaneous transluminal coronary angioplasty (PTCA) with lesions considered suitable for quantitative coronary angiographic

  13. Intradural vertebral endarterectomy with nonautologous patch angioplasty for refractory vertebrobasilar ischemia: Case report and literature review

    OpenAIRE

    Timothy Uschold; Adib A Abla; Wilson, David A.; McDougall, Cameron G.; Peter Nakaji

    2014-01-01

    Background: The natural history of patients with symptomatic vertebrobasilar ischemic symptoms due to chronic bilateral vertebral artery occlusive disease is progressive, and poses significant challenges when refractory to medical therapy. Surgical treatment options depend largely on location and characteristics of the atheroma (s), and generally include percutaneous transluminal angioplasty (PTA) with or without stent placement, posterior circulation revascularization (bypass), extracranial ...

  14. Experimental and numerical investigation of wire waveguides for therapeutic ultrasound angioplasty

    OpenAIRE

    Noone, Declan, (Thesis)

    2008-01-01

    Therapeutic ultrasound angioplasty is an emerging minimally invasive cardiovascular procedure for disrupting atherosclerotic lesions using small diameter wire waveguides. The lesions are damaged through a combination of direct ablation, pressure waves, cavitation and acoustic streaming caused by distal-tip displacements at ultrasonic frequencies. Numerical and experimental methods are used to investigate the outputs of the wire waveguides during ultrasonic activation. A commercially avail...

  15. Immediate versus deferred coronary angioplasty in non-ST-segment elevation acute coronary syndromes

    NARCIS (Netherlands)

    R.K. Riezebos; E. Ronner; E. ter Bals; T. Slagboom; P.C. Smits; J.M. ten Berg; F. Kiemeneij; G. Amoroso; M.S. Patterson; M.J. Suttorp; J.G.P. Tijssen; G.J. Laarman

    2009-01-01

    BACKGROUND: The field of acute coronary syndromes is characterised by an increasing tendency towards early invasive catheter-based diagnostics and therapeutics-a practice based on observational and retrospective data. OBJECTIVE: To compare immediate versus deferred angioplasty in patients with non-S

  16. Percutaneous transluminal angioplasty of iliac and femoral arteries in severe lower-limb ischaemia

    DEFF Research Database (Denmark)

    Jørgensen, B; Henriksen, L O; Karle, A;

    1988-01-01

    Percutaneous transluminal angioplasty was performed 92 times in 86 patients with severe lower-limb ischaemia (40% occlusion), giving rise to rest pain and/or gangrene. The patients were thereafter observed for periods up to 5 years. Criteria for success were appearance of normal groin pulse (iliac...

  17. Late hemodynamic failure following percutaneous transluminal angioplasty for long and multifocal femoropopliteal stenoses

    DEFF Research Database (Denmark)

    Jørgensen, B; Tønnesen, K H; Holstein, P

    1991-01-01

    The outcome of percutaneous transluminal angioplasty (PTA) was evaluated for treatment of 87 limbs with femoropopliteal stenoses, including 55 short stenoses (2.4 +/- 1.6 cm, mean +/- SD), seven single long stenoses (10.4 +/- 2.0 cm), and 25 multifocal stenoses (2.1 +/- 1.6 cm), where two to four...

  18. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    International Nuclear Information System (INIS)

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful

  19. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won [Konyang University Hospital, Daejeon (Korea, Republic of)

    2005-12-15

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful.

  20. A New Approach: Regional Nerve Blockade for Angioplasty of the Lower Limb

    International Nuclear Information System (INIS)

    Purpose. An audit study investigated the pilot use of regional nerve block analgesia (as an alternative to sedative/opiate, general or central neuraxial anesthesia) performed by radiologists with the assistance of imaging techniques during complex prolonged angiography. Methods. Radiologists were trained by anesthetic consultants to administer and use lower limb peripheral nerve block for difficult prolonged angioplasty procedures for patients with severe lower limb rest pain who were unable to lie in the supine position. In a pilot study 25 patients with limb-threatening ischemia received sciatic and femoral nerve blockade for angioplasty. The technique was developed and perfected in 12 patients and in a subsequent 13 patients the details of the angiography procedures, peripheral anesthesia, supplementary analgesia, complications, and pain assessment scores were recorded. Pain scores were also recorded in 11 patients prior to epidural/spinal anesthesia for critical ischemic leg angioplasty. Results. All patients with peripheral nerve blockade experienced a reduction in their ischemic rest pain to a level that permitted angioplasty techniques to be performed without spinal, epidural or general analgesia. In patients undergoing complex angioplasty intervention, the mean pain score by visual analogue scale was 3.7, out of a maximum score of 10. Conclusions. The successful use of peripheral nerve blocks was safe and effective as an alternative to sedative/opiate, epidural or general anesthesia in patients undergoing complex angiography and has optimized the use of radiological and anesthetic department resources. This has permitted the frequent radiological treatment of patients with limb-threatening ischemia and reduced delays caused by the difficulty in enlisting the help of anesthetists, often at short notice, from the busy operating lists

  1. Retrospective Study of Rapid-Exchange Monorail Versus Over-the-Wire Technique for Femoropopliteal Angioplasty

    International Nuclear Information System (INIS)

    PurposeThe purpose of this study was to compare procedural outcome of rapid-exchange (RX) monorail versus conventional over-the-wire (OTW) technique for femoropopliteal angioplasty.Materials and MethodsDemographic data, procedure details, angioplasty success, and complications of 328 consecutive percutaneous transluminal angioplasties (PTAs) were collected from a prospective database and retrospectively analyzed. Procedure details included duration of fluoroscopy, area-dose product, amount of contrast agent, sheath sizes, access route, length of stenosis, presence of total occlusion, technical and anatomical success (residual stenosis <30% in the absence of complications), need for bail-out stenting, and periprocedural complications. The RX technique alone was used in 102 of 328 cases (31%); the OTW technique, in 226 of 328 of cases (68%).ResultsTechnical success was 98% for the RX versus 95.4% for the OTW technique (p = 0.2). A significantly greater number of stents had to be implanted due to angioplasty failure when the OTW technique was used (RX, 5.9%; OTW, 13.7%; p = 0.04). There were no significant differences in fluorocopy time, dose-area product, or amount of contrast medium used. The RX system facilitated the use of smaller sheath sizes (5 Fr = 38% and 6 Fr = 59% for RX versus 5 Fr = 16.8% and ≥6 Fr = 82.5% for OTW) but showed only a tendency toward lower overall complication rates (16.6% [17/102] in the RX group versus 19.9% [45/226] in the OTW group; p = 0.09). There was no effect on length of hospitalization. RX monorail systems were not associated with higher procedural costs when compared to conventional OTW technique.ConclusionWe conclude that RX monorail systems seem to enhance the technical success of femoropopliteal angioplasty. Although smaller sheath sizes can be used due to the lower profile of the RX systems, there is only a tendency toward lower complication rates.

  2. Clinical observation of intraluminal stent angioplasty in the treatment of renal arterial stenoses

    International Nuclear Information System (INIS)

    Objective: To evaluate the clinical application of intraluminal stent angioplasty (PTRAS) in the treatment of renal arterial stenoses. Methods: A retrospective study was done in 28 patients with renal arterial stenoses. Primary renal artery stenting was performed in 28 consecutive patients (36 renal arteries). Blood pressure, serum creating, the number of anti-hypertensive medications were recorded at 1, 6, 12 month post stent angioplasty respectively. Arterial angiography was also taken 1 year later to evaluate the incidence of restenosis. Results: Technical success rate was 100% achieving in all patients without serious complications. Primary successful patently rate reached 82% (renal artery 86%), secondary successful rate was 89% (renal artery 90%). Systolic and diastolic blood pressure were reduced significantly (P<0.01) at 1,6,12 month after stent angioplasty comparing with baseline and clinical improvement (cured + improved) of hypertension reached 100%, 92.9%, 89.3% respectively. There were no significant differences between serum creatine level and the number of anti-hypertensive medications before and after stent angioplasty. One year later, 14.3% of all patients showed improvement of renal function, 64.3% remained in stabilization and 21.4% fell into deterioration. Angiographic restenosis was found in 3 cases one year after stent angioplasty. Complications included 1 hematoma at puncture site and 3 transient azotaemia. Conclusions: PTRAS can be performed safely with high technical success and beneficial to the majority of patients with hypertension or renal insufficiency and therefore it should be the first choice in treating renal arterial stenoses

  3. Fluoroscopically Guided Balloon Dilation for Postintubation Tracheal Stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woong Hee; Kim, Jin Hyoung, E-mail: m1fenew@daum.net; Park, Jung-Hun [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of)

    2013-10-15

    Purpose: Little was known about the safety and long-term efficacy of fluoroscopically guided balloon dilation for postintubation tracheal stenosis. The purpose of this study was to evaluate the safety and long-term efficacy of fluoroscopically guided balloon dilation in patients with postintubation tracheal stenosis. Methods: From February 2000 to November 2010, 14 patients underwent fluoroscopically guided balloon dilation for postintubation tracheal stenosis. Technical success, clinical success, and complications were evaluated. Patients were followed up for recurrent symptoms. Results: In all patients, fluoroscopically guided balloon dilation was technically and clinically successful with no major complications. Following the initial procedure, six patients (43 %) remained asymptomatic during a follow-up period. Obstructive symptoms recurred in eight patients (57 %) within 6 months (mean, 1.7 months), who were treated with repeat balloon dilation (n = 4) and other therapies. Of the four patients who underwent repeat balloon dilation, three became asymptomatic. One patient became asymptomatic after a third balloon dilation. On long-term (mean, 74 months) follow-up, 71 % of patients experienced relief of symptoms following fluoroscopically guided balloon dilation. Conclusions: Fluoroscopically guided balloon dilation may be safe, is easy to perform, and resulted in effective treatment in patients with postintubation tracheal stenosis.

  4. Acoustical characterization of exploding hydrogen-oxygen balloons.

    Science.gov (United States)

    Vernon, Julia A; Gee, Kent L; Macedone, Jeffrey H

    2012-03-01

    Exploding hydrogen-oxygen balloons are popular chemistry demonstrations. Although initial research experimentally quantified potential hearing risk via analysis of peak levels [K. L. Gee et al., J. Chem. Educ. 87, 1039-1044 (2010)], further waveform and spectral analyses have been conducted to more fully characterize these impulsive noise sources. While hydrogen-only balloons produce inconsistent reactions and relatively low, variable levels, stoichiometrically mixed hydrogen-oxygen balloons produce consistent high-amplitude noise waveforms. Preliminary consideration is also given to the potential use of these exploding balloons in architectural acoustics applications. PMID:22423815

  5. The role of scientific ballooning for exploration of the magnetosphere

    International Nuclear Information System (INIS)

    The magnetosphere is explored in situ by satellites, but measurements near the low altitude magnetospheric boundary by rockets, balloons and groundbased instruments play a very significant role. The geomagnetic field provides a frame with anisotropic wave and particle propagation effects, enabling remote sensing of the distant magnetosphere by means of balloon-borne and groundbased instruments. Examples will be given of successful studies, with coordinated satellite and balloon observations, of substorm, pulsation and other phenomena propagating both along and across the geomagnetic field. Continued efforts with sophisticated balloon-borne instrumentations should contribute substantially to our understanding of magnetospheric physics. (Author)

  6. Planetary Science with Balloon-Borne Telescopes

    Science.gov (United States)

    Kremic, Tibor; Cheng, Andy; Hibbitts, Karl; Young, Eliot

    2015-01-01

    The National Aeronautics and Space Administration (NASA) and the planetary science community have recently been exploring the potential contributions of stratospheric balloons to the planetary science field. A study that was recently concluded explored the roughly 200 or so science questions raised in the Planetary Decadal Survey report and found that about 45 of those questions are suited to stratospheric balloon based observations. In September of 2014, a stratospheric balloon mission called BOPPS (which stands for Balloon Observation Platform for Planetary Science) was flown out of Fort Sumner, New Mexico. The mission had two main objectives, first, to observe a number of planetary targets including one or more Oort cloud comets and second, to demonstrate the applicability and performance of the platform, instruments, and subsystems for making scientific measurements in support planetary science objectives. BOPPS carried two science instruments, BIRC and UVVis. BIRC is a cryogenic infrared multispectral imager which can image in the.6-5 m range using an HgCdTe detector. Narrow band filters were used to allow detection of water and CO2 emission features of the observed targets. The UVVis is an imager with the science range of 300 to 600 nm. A main feature of the UVVis instrument is the incorporation of a guide camera and a Fine Steering Mirror (FSM) system to reduce image jitter to less than 100 milliarcseconds. The BIRC instrument was used to image targets including Oort cloud comets Siding Spring and Jacques, and the dwarf planet 1 Ceres. BOPPS achieved the first ever earth based CO2 observation of a comet and the first images of water and CO2 of an Oort cloud comet (Jacques). It also made the first ever measurement of 1Ceres at 2.73 m to refine the shape of the infrared water absorption feature on that body. The UVVis instrument, mounted on its own optics bench, demonstrated the capability for image correction both from atmospheric disturbances as well as some

  7. Stratospheric Balloons for Planetary Science and the Balloon Observation Platform for Planetary Science (BOPPS) Mission Summary

    Science.gov (United States)

    Kremic, Tibor; Cheng, Andrew F.; Hibbitts, Karl; Young, Eliot F.; Ansari, Rafat R.; Dolloff, Matthew D.; Landis, Rob R.

    2015-01-01

    NASA and the planetary science community have been exploring the potential contributions approximately 200 questions raised in the Decadal Survey have identified about 45 topics that are potentially suitable for addressing by stratospheric balloon platforms. A stratospheric balloon mission was flown in the fall of 2014 called BOPPS, Balloon Observation Platform for Planetary Science. This mission observed a number of planetary targets including two Oort cloud comets. The optical system and instrumentation payload was able to provide unique measurements of the intended targets and increase our understanding of these primitive bodies and their implications for us here on Earth. This paper will discuss the mission, instrumentation and initial results and how these may contribute to the broader planetary science objectives of NASA and the scientific community. This paper will also identify how the instrument platform on BOPPS may be able to contribute to future balloon-based science. Finally the paper will address potential future enhancements and the expected science impacts should those enhancements be implemented.

  8. Comparative study of conducting iliac angioplasties with digital subtraction and conventional angiography. Incidence on true (consumable) costs

    International Nuclear Information System (INIS)

    Differences in time and cost were evaluated between the performance of iliac angioplasty with conventional (AC) and digital subtraction (AN) angiography, after a total of 27 angioplasties (13 with AC and 14 with AN). Excluding amortization of material and personnel costs, findings confirmed a certain number of advantages for AN: gain in time of about 34%, decrease of about 14% in charges, and notably of 83% in expenditure on films and 50% on contrast media

  9. Captopril for prevention of Contrast Induced Nephropathy in patients undergoing Coronary Angioplasty: A double blind placebo controlled clinical trial

    OpenAIRE

    Hashemi, M.; Kharazi, A; Shahidi, S.

    2005-01-01

    Background: Contrast induced nephropathy is a potential cause of mortality and morbidity in patients undergoing angiography–angioplasty. Except for hydrating and probably low – isoosmolar contrast agents in high risk groups, other modalities have not provided benefit. We investigated preventive effects of captopril for contrast induced nephropathy during angiography–angioplasty. Methods: In a double blind placebo controlled clinical trial, 88 patients were randomized to two groups: 42 pa...

  10. Long term results of endovascular treatment in renal arterial stenosis from Takayasu arteritis: Angioplasty versus stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hong Suk, E-mail: hongsukpark@gmail.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Do, Young Soo, E-mail: ysdo@skku.edu [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Kim, Duk-Kyung, E-mail: dukkyung.kim@samsung.com [Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, Sung Wook, E-mail: sw.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Shin, Sung Wook, E-mail: sw88.shin@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Cho, Sung Ki, E-mail: sungkismc@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Hyun, Dongho, E-mail: mesentery.hyun@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, In Wook, E-mail: inwook.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of)

    2013-11-01

    Purpose: To retrospectively evaluate and compare the long term patency and antihypertensive effect of angioplasty and stent insertion in renal artery stenosis caused by Takayasu arteritis, with CT angiography and clinical follow-up. Materials and methods: We retrospectively analyzed and compared effects on hypertension and patency of renal artery in 16 patients (age ranging from 16 to 58 years, mean: 32.1 years) with renovascular hypertension caused by Takayasu arteritis who underwent endovascular treatment including angioplasty (n = 13) and stent placement (n = 9) for 22 stenotic renal arteries. Results: Technical success was 95% (21/22) without major complications. In the last follow-up CT angiogram (mean 85 ± 41 months), restenosis was 8% (1/12) in angioplasty and 66% (6/9) in stent. Patency rates of angioplasty were 100%, 91.7%, 91.7% and primary unassisted and primary assisted patency rates of stent placement were 55.6%, 33.3%, 33.3% and 88.9%, 66.7%, 55.6% at 1-, 3- and 5-years, respectively. In clinical follow-up (mean 120 ± 37.8 months, range 48–183 months), beneficial effects on hypertension were obtained in 87% of patients (13/15) and there was no significant difference between the patients who were treated by only angioplasty and the patients who received stent placement in at least one renal artery, regardless of whether or not angioplasty had been performed in the other renal artery. Conclusion: Compared with stent placement, angioplasty demonstrated better long term patency and similar clinical benefit on renovascular hypertension in renal artery stenosis of Takayasu arteritis. We suggest that stent placement should be reserved for obvious angioplasty failure.

  11. Long term results of endovascular treatment in renal arterial stenosis from Takayasu arteritis: Angioplasty versus stent placement

    International Nuclear Information System (INIS)

    Purpose: To retrospectively evaluate and compare the long term patency and antihypertensive effect of angioplasty and stent insertion in renal artery stenosis caused by Takayasu arteritis, with CT angiography and clinical follow-up. Materials and methods: We retrospectively analyzed and compared effects on hypertension and patency of renal artery in 16 patients (age ranging from 16 to 58 years, mean: 32.1 years) with renovascular hypertension caused by Takayasu arteritis who underwent endovascular treatment including angioplasty (n = 13) and stent placement (n = 9) for 22 stenotic renal arteries. Results: Technical success was 95% (21/22) without major complications. In the last follow-up CT angiogram (mean 85 ± 41 months), restenosis was 8% (1/12) in angioplasty and 66% (6/9) in stent. Patency rates of angioplasty were 100%, 91.7%, 91.7% and primary unassisted and primary assisted patency rates of stent placement were 55.6%, 33.3%, 33.3% and 88.9%, 66.7%, 55.6% at 1-, 3- and 5-years, respectively. In clinical follow-up (mean 120 ± 37.8 months, range 48–183 months), beneficial effects on hypertension were obtained in 87% of patients (13/15) and there was no significant difference between the patients who were treated by only angioplasty and the patients who received stent placement in at least one renal artery, regardless of whether or not angioplasty had been performed in the other renal artery. Conclusion: Compared with stent placement, angioplasty demonstrated better long term patency and similar clinical benefit on renovascular hypertension in renal artery stenosis of Takayasu arteritis. We suggest that stent placement should be reserved for obvious angioplasty failure

  12. Ballooning Spiders: The Case for Electrostatic Flight

    CERN Document Server

    Gorham, Peter W

    2013-01-01

    We consider general aspects of the physics underlying the flight of Gossamer spiders, also known as ballooning spiders. We show that existing observations and the physics of spider silk in the presence of the Earth's static atmospheric electric field indicate a potentially important role for electrostatic forces in the flight of Gossamer spiders. A compelling example is analyzed in detail, motivated by the observed "unaccountable rapidity" in the launching of such spiders from H.M.S. Beagle, recorded by Charles Darwin during his famous voyage.

  13. Thrombus aspiration catheter is a Dottering balloon.

    Science.gov (United States)

    Sheshagiri Rao, D; Barik, Ramachandra; Prasad, Akula Siva

    2016-01-01

    Coronary angiogram in a young man with history of STEMI with delayed presentation revealed subtotal occlusion of left anterior descending artery (LAD) with large thrombotic filling defect distal to the critical lesion. PCI was preferred without delay because of ongoing chest pain. Several runs of thrombus aspiration failed to detect any visible thrombus. However, the immediate angiogram after thrombus aspiration showed complete distal embolization of the thrombus which could have been achieved by Dottering or balloon dilatation. In contrary to the general perception, does thrombus aspiration push more thrombus than it can aspirate? PMID:27543477

  14. Ballooning instability precursors to high β disruptions

    International Nuclear Information System (INIS)

    Strongly ballooning modes have been found as precursors to high β disruptions on TFTR. The modes are typically localized to a region spanning about 60 degree in the toroidal direction. The toroidal localization is associated with lower frequency, global Magneto-Hydro-Dynamic (MHD) activity, typically an ideal n = 1 kink mode. They have moderate to high frequency (f = 10--20 frot), implying toroidal mode numbers in the range n = 10--20. The growth rates for the modes are large, of order 104/sec

  15. General theory of kinetic ballooning modes

    International Nuclear Information System (INIS)

    The ballooning mode formalism, previously developed for the ideal MHD problem, is applied here to the kinetic problem in tokamaks. The general two-dimensional equation governing drift and trapped-electron eigenmodes reduces to a one-dimensional integral equation along the lines of force with the radial structure determined by a WKB procedure. Comparisons made between the present one-dimensional code and a previous two-dimensional code embodying identical physical assumptions indicate reasonable agreement. This correspondence holds both for the structure along the field line and for the radial structure in the special case of closely spaced turning points

  16. Double-balloon endoscopy: Who needs it?

    DEFF Research Database (Denmark)

    Hendel, J.W.; Vilmann, P.; Jensen, T.

    2008-01-01

    Objective. Double-balloon endoscopy (DBE) made the small bowel accessible to inspection and therapy in its entirety. However, DBE is a time-consuming procedure that requires a highly skilled endoscopist, several nurses and - more often than not - anesthesiological support. This makes the selection...... of patients for DBE a pivotal point. The mainstay of this screening examination of the small bowel is capsule endoscopy (CE). The aim of this study was to describe the results of this screening procedure and the subsequent DBE in patients with suspected mid-gastrointestinal bleeding (MGIB). Material...

  17. Pneumothorax, music and balloons: A case series

    Directory of Open Access Journals (Sweden)

    Shiferaw Dejene

    2013-01-01

    Full Text Available We describe two cases of spontaneous pneumothorax in young healthy adults with no underlying structural lung disease. The onset of pneumothorax was following physical activity including playing musical instruments and blowing of balloons. There is sparse data evaluating the pathophysiology of primary spontaneous pneumothorax in relation to increased mouth pressures. These cases highlight the possible physical effect of valsalva manoeuvre on transpulmonary pressures, and the potential risk of developing pneumothorax in otherwise healthy individuals. This aspect of pneumothorax development is worthy of further exploration, to better elucidate the mechanism and enhance our understanding of this common respiratory presentation.

  18. Pneumothorax, music and balloons: A case series.

    Science.gov (United States)

    Dejene, Shiferaw; Ahmed, Fahim; Jack, Kastelik; Anthony, Arnorld

    2013-07-01

    We describe two cases of spontaneous pneumothorax in young healthy adults with no underlying structural lung disease. The onset of pneumothorax was following physical activity including playing musical instruments and blowing of balloons. There is sparse data evaluating the pathophysiology of primary spontaneous pneumothorax in relation to increased mouth pressures. These cases highlight the possible physical effect of valsalva manoeuvre on transpulmonary pressures, and the potential risk of developing pneumothorax in otherwise healthy individuals. This aspect of pneumothorax development is worthy of further exploration, to better elucidate the mechanism and enhance our understanding of this common respiratory presentation. PMID:23922614

  19. Explosive Ballooning Flux Tubes in Tokamaks

    CERN Document Server

    Ham, C J; Brochard, G; Wilson, H R

    2016-01-01

    Tokamak stability to, potentially explosive, `ballooning' displacements of elliptical magnetic flux tubes is examined in large aspect ratio equilibrium. Above a critical pressure gradient the energy stored in the plasma may be lowered by finite (but not infinitesimal) displacements of such tubes (metastability). Above a higher pressure gradient, the linear stability boundary, such tubes are linearly and nonlinearly unstable. The flux tube displacement can be of the order of the pressure gradient scale length. Plasma transport from displaced flux tubes may result in rapid loss of confinement.

  20. Guidelines and Suggestions for Balloon Gondola Design

    Science.gov (United States)

    Franco, Hugo

    2016-01-01

    The Columbia Scientific Balloon Facility is responsible for ensuring that science payloads meet the appropriate design requirements. The ultimate goal is to ensure that payloads stay within the allowable launch limits as well as survive the termination event. The purpose of this presentation is to provide some general guidelines for Gondola Design. These include rules and reasons on why CSBF has a certain preference and location for certain components within the gondola as well as other suggestions. Additionally, some recommendations are given on how to avoid common pitfalls.

  1. Simultaneous stent expansion/balloon deflation technique to salvage failed balloon remodeling.

    Science.gov (United States)

    Ladner, Travis R; He, Lucy; Davis, Brandon J; Froehler, Michael T; Mocco, J

    2016-04-01

    Herniation, with possible embolization, of coils into the parent vessel following aneurysm coiling remains a frequent challenge. For this reason, balloon or stent assisted embolization remains an important technique. Despite the use of balloon remodeling, there are occasions where, on deflation of the balloon, some coils, or even the entire coil mass, may migrate. We report the successful use of a simultaneous adjacent stent deployment bailout technique in order to salvage coil prolapse during balloon remodeling in three patients. Case No 1 was a wide neck left internal carotid artery bifurcation aneurysm, measuring 9 mm×7.9 mm×6 mm with a 5 mm neck. Case No 2 was a complex left superior hypophyseal artery aneurysm, measuring 5.3 mm×4 mm×5 mm with a 2.9 mm neck. Case No 3 was a ruptured right posterior communicating artery aneurysm, measuring 4 mm×4 mm×4.5 mm with a 4 mm neck. This technique successfully returned the prolapsed coil mass into the aneurysm sac in all cases without procedural complications. The closed cell design of the Enterprise VRD (Codman and Shurtleff Inc, Raynham, Massachusetts, USA) makes it ideal for this bailout technique, by allowing the use of an 0.021 inch delivery catheter (necessary for simultaneous access) and by avoiding the possibility of an open cell strut getting caught on the deflated balloon. We hope this technique will prove useful to readers who may find themselves in a similar predicament. PMID:25801773

  2. Flight Qualification of the NASA's Super Pressure Balloon

    Science.gov (United States)

    Cathey, Henry; Said, Magdi; Fairbrother, Debora

    Designs of new balloons to support space science require a number of actual flights under various flight conditions to qualify them to as standard balloon flight offerings to the science community. Development of the new Super Pressure Balloon for the National Aeronautics and Space Administration’s Balloon Program Office has entailed employing new design, analysis, and production techniques to advance the state of the art. Some of these advances have been evolutionary steps and some have been revolutionary steps requiring a maturing understanding of the materials, designs, and manufacturing approaches. The NASA Super Pressure Balloon development end goal is to produce a flight vehicle that is qualified to carry a ton of science instrumentation, at an altitude greater than 33 km while maintaining a near constant pressure altitude for extended periods of up to 100 days, and at any latitude on the globe. The NASA’s Balloon Program Office has pursued this development in a carefully executed incremental approach by gradually increasing payload carrying capability and increasing balloon volume to reach these end goal. A very successful test flight of a ~200,700 m3 balloon was launch in late 2008 from Antarctica. This balloon flew for over 54 days at a constant altitude and circled the Antarctic continent almost three times. A larger balloon was flown from Antarctica in early 2011. This ~422,400 m3 flew at a constant altitude for 22 days making one circuit around Antarctica. Although the performance was nominal, the flight was terminated via command to recover high valued assets from the payload. The balloon designed to reach the program goals is a ~532,200 m3 pumpkin shaped Super Pressure Balloon. A test flight of this balloon was launched from the Swedish Space Corporation’s Esrange Balloon Launch Facilities near Kiruna, Sweden on 14 August, 2012. This flight was another success for this development program. Valuable information was gained from this short test

  3. Salvage living donor liver transplantation after percutaneous transluminal angioplasty for recurrent Budd-Chiari syndrome: a case report

    Directory of Open Access Journals (Sweden)

    Mitoro Akira

    2011-03-01

    Full Text Available Abstract Introduction Budd-Chiari syndrome is a very rare pathological entity that ultimately leads to liver failure. Several therapeutic modalities, including percutaneous transluminal angioplasty, have been attempted to save the life of patients with Budd-Chiari syndrome. Few reports have described a salvage living donor liver transplantation performed after percutaneous transluminal angioplasty in a patient with acute Budd-Chiari syndrome. Case presentation A 26-year-old Japanese man developed severe progressive manifestations, such as massive ascites and hematemesis due to rupture of esophageal varices. After making several investigations, we diagnosed the case as Budd-Chiari syndrome. We first performed percutaneous transluminal angioplasty to dilate a short-segment stenosis of his inferior vena cava. The first percutaneous transluminal angioplasty greatly improved the clinical manifestations. However, after a year, re-stenosis was detected, and a second percutaneous transluminal angioplasty failed to open the severe stricture of his inferior vena cava. Since our patient had manifestations of acute liver failure, we decided to perform salvage living donor liver transplantation from his brother. The transplantation was successfully performed and all clinical manifestations were remarkably alleviated. Conclusion In cases of recurrent Budd-Chiari syndrome, the blocked hepatic venous outflow is not always relieved, even with invasive therapies. We have to take into account the possibility of adopting alternative salvage therapies if the first therapeutic modalities fail. When invasive therapy such as percutaneous transluminal angioplasty fails, liver transplantation should be considered as an alternative option.

  4. Recent developments in the scientific ballooning in India

    Science.gov (United States)

    Manchanda, R.; Sreenivasan, S.; Subbarao, J.; Kumar, P.

    RECENT DEVELOPMENTS IN THE SCIENTIFIC BALLOONING IN INDIA R. K. Manchanda1, S. Sreenivasan2, J. V. Subbarao2, P. R. Kumar2 1. Tata Institute of Fundamental Research Colaba, Mumbai-400 005, India. 2. TIFR Balloon Facility, PO Box 5, ECIL Post Office, Hyderabad-500 762, India ravi@tifr.res.in/FAX: +91-22-2152110 National Balloon facility operated by TIFR in Hyderabad, India is the only one of its kind in the world, which combines both, the in-house balloon production and a complete flight support for scientific ballooning. In the past few years we executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to 780,000 m3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years and the results of the test flight conducted to qualify new sub systems will be presented.

  5. Methods for tracking of balloons and rockets at Esrange

    Science.gov (United States)

    Hedqvist, Tomas

    2001-08-01

    At Esrange several methods are used for tracking of balloons and rockets with help of radar, Vaisala sounding data, ARGOS and GPS information. Information from these different sources is fed into a computer system for processing, and for display on adapted systems. Data from balloon flights are displayed on a digital map, which includes population data and a system to predict impact point of the balloon. Data from rocket flights can be displayed either on a digital map, or in a system for range safety purpose. Signals from various sources are converted into a data format used in the new ATC (Air Traffic Control) transponder system in order to ease future integration into this system. Data from the GPS system in NMEA format can also be adopted directly into the tracking system for both balloon and rocket flight. Balloon tracking data is also transferred via Internet to ATCs centres for flight safety reasons. Future developments: A new system for wind measurements will be created from "throw away" GPS sondes. In air traffic transponders, the expensive altimeter will be replaced by an inexpensive GPS system. For recovery, Argos-GPS on balloons will be used for real-time tracking, position information via satellites and as a support system for recovery by helicopter. Balloons equipped with the Inmarsat system, for long duration balloon flights, will have their position displayed in the digital map system.

  6. The Evaluation of Endoscopic Balloon Dilation Treatment for

    Directory of Open Access Journals (Sweden)

    Shokri-Shirvani Javad

    2009-10-01

    Full Text Available Balloon dilatation of stricture is one of the new treatment methods among patients with gastric outlet obstruction (GOO. However, the prevalence and underlying etiologies of GOO in various populations are different. The goal of the present study was to determine the effectiveness of endoscopic balloon dilatation and factors that would affect its success rate patients with benign etiology for GOO. Forty-five patients with the symptoms of benign GOO were randomly selected. Gastric outlet was delineated using double channel videoendoscopy. The information of initial balloon dilation was collected from recorded files. Balloon dilatation was repeated during the mean follow up of 9.9 ± 5.8 months. The severity of gastric pain was measured immediately before balloon dilatation and one month after procedure and was rated on a 10 cm visual analogue scale. The mean age of patients was 43.7 ± 18.1 years and 86.7% of them were men. Furthermore, 71.1% were H pylori positive. Response rate to endoscopic balloon dilatation was 80% and 8 patients underwent surgical resection. Weight loss was more frequent in non-responding group. The pain severity was significantly reduced more in responding subjects. No meaningful relationships were found between the responses to balloon dilatation and positive H pylori and cigarette smoking. Endoscopic balloon dilation is safe and effective for most patients with benign gastric outlet obstruction and has favorable long-term outcome.

  7. Reversible transient apical ballooning syndrome with coronary lesions

    Institute of Scientific and Technical Information of China (English)

    Yunshan Cao; Min Zhang; Xiang Li; Ping Xie; Lynn Cronin

    2009-01-01

    Transient apical ballooning syndrome(Tako-Tsubo syndrome or ampulla cardiomyopathy) occurs predominantly in women over 60 years of age with a history of recent physical or psychological stress. We present a case of a male patient with reversible transient apical ballooning syndrome with significant coronary lesions and other ECG changes that did not explain the clinical symptoms.

  8. Failure of epoprostenol (prostacyclin, PGI2) to inhibit platelet aggregation and to prevent restenosis after coronary angioplasty: results of a randomised placebo controlled trial.

    OpenAIRE

    Gershlick, A H; Spriggins, D.; Davies, S W; Syndercombe Court, Y D; Timmins, J.; Timmis, A D; Rothman, M. T.; Layton, C; Balcon, R

    1994-01-01

    OBJECTIVE--To study the effect of epoprostenol (prostacyclin, PGI2) given before, during, and for 36 h after coronary angioplasty on restenosis at six months and to evaluate the transcardiac gradient of platelet aggregation before and after percutaneous transluminal coronary angioplasty (PTCA) in treated and placebo groups. DESIGN--Double blind placebo controlled randomised study. PATIENTS--135 patients with successful coronary angioplasty. METHODS--Intravenous infusion of PGI2 (4 ng/kg/ml) o...

  9. Spectrum of the ballooning Schroedinger equation

    International Nuclear Information System (INIS)

    The ballooning Schroedinger equation (BSE) is a model equation for investigating global modes that can, when approximated by a Wentzel-Kramers-Brillouin (WKB) ansatz, be described by a ballooning formalism locally to a field line. This second order differential equation with coefficients periodic in the independent variable θk is assumed to apply even in cases where simple WKB quantization conditions break down, thus providing an alternative to semiclassical quantization. Also, it provides a test bed for developing more advanced WKB methods: e.g. the apparent discontinuity between quantization formulae for open-quotes trappedclose quotes and open-quotes passingclose quotes modes, whose ray paths have different topologies, is removed by extending the WKB method to include the phenomena of tunnelling and reflection. The BSE is applied to instabilities with shear in the real part of the local frequency, so that the dispersion relation is inherently complex. As the frequency shear is increased, it is found that trapped modes go over to passing modes, reducing the maximum growth rate by averaging over θk

  10. EUSO-Balloon: The first flight

    Science.gov (United States)

    Scotti, Valentina; Osteria, Giuseppe

    2016-07-01

    EUSO-Balloon is a pathfinder mission for JEM-EUSO, the near-UV telescope proposed to be installed on board the International Space Station (ISS). The main objective of this pathfinder mission is to perform a full scale end-to-end test of all the key technologies of JEM-EUSO detectors and to measure the UV background. The JEM-EUSO instrument consists of UV telescope designed to focus the signal of the UV tracks generated by Extreme Energy Cosmic Rays propagating in Earth's atmosphere, onto a finely pixelized UV camera. The EUSO-Balloon instrument, smaller than the one designed for the ISS, was launched on August 2014 from Timmins (Ontario, Canada). The flight lasted about five hours and the instrument reached a float altitude of about 40 km. From this altitude the telescope registered, at a rate of 400 000 frames/s, the nightglow background on forests, lakes and clouds, as well as city lights and artificial air showers tracks generated by means of a laser installed on an helicopter flying inside its field of view. In this contribution we will describe the instrument and its performance during the first flight.

  11. Balloon concepts for scientific investigation of Mars and Jupiter

    Science.gov (United States)

    Ash, R. L.

    1979-01-01

    Opportunities for scientific investigation of the atmospheric planets using buoyant balloons have been explored. Mars and Jupiter were considered in this study because design requirements at those planets bracket nominally the requirements at Venus, and plans are already underway for a joint Russian-French balloon system at Venus. Viking data has provided quantitative information for definition of specific balloon systems at Mars. Free flying balloons appear capable of providing valuable scientific support for more sophisticated Martian surface probes, but tethered and powered aerostats are not attractive. The Jovian environment is so extreme, hot atmosphere balloons may be the only scientific platforms capable of extended operations there. However, the estimated system mass and thermal energy required are very large.

  12. The ballooning of fuel cladding tubes: theory and experiment

    International Nuclear Information System (INIS)

    Under some conditions, fuel clad ballooning can result in considerable strain before rupture. If ballooning were to occur during a loss-of-coolant accident (LOCA), the resulting substantial blockage of the sub-channel would restrict emergency core cooling. However, circumferential temperature gradients that would occur during a LOCA may significantly limit the average strain at failure. Understandably, the factors that control ballooning and rupture of fuel clad are required for the analysis of a LOCA. Considerable international effort has been spent on studying the deformation of Zircaloy fuel cladding under conditions that would occur during a LOCA. This effort has established a reasonable understanding of the factors that control the ballooning, failure time, and average failure strain of fuel cladding. In this paper, both the experimental and theoretical studies of the fuel clad ballooning are reviewed. (author)

  13. Correlating coating characteristics with the performance of drug-coated balloons--a comparative in vitro investigation of own established hydrogel- and ionic liquid-based coating matrices.

    Directory of Open Access Journals (Sweden)

    Sebastian Kaule

    Full Text Available Drug-coated balloons (DCB, which have emerged as a therapeutic alternative to drug-eluting stents in percutaneous cardiovascular intervention, are well described with regard to clinical efficacy and safety within a number of clinical studies. In vitro studies elucidating the correlation between coating additive and DCB performance are however rare but considered important for the understanding of DCB requirements and the improvement of established DCB. In this regard, we examined three different DCB-systems, which were developed in former studies based on the ionic liquid cetylpyridinium salicylate, the body-own hydrogel hyaluronic acid and the pharmaceutically well-established hydrogel polyvinylpyrrolidone, considering coating morphology, coating thickness, drug-loss, drug-transfer to the vessel wall, residual drug-concentration on the balloon surface and entire drug-load during simulated use in an in vitro vessel model. Moreover, we investigated particle release of the different DCB during simulated use and determined the influence of the three coatings on the mechanical behavior of the balloon catheter. We could show that coating characteristics can be indeed correlated with the performance of DCB. For instance, paclitaxel incorporation in the matrix can reduce the drug wash-off and benefit a high drug transfer. Additionally, a thin coating with a smooth surface and high but delayed solubility can reduce drug wash-off and decrease particle burden. As a result, we suggest that it is very important to characterize DCB in terms of mentioned properties in vitro in addition to their clinical efficacy in order to better understand their function and provide more data for the clinicians to improve the tool of DCB in coronary angioplasty.

  14. Percutaneous balloon mitral valvuloplasty by the Inoue balloon technique: the procedure of choice for treatment of mitral stenosis.

    Science.gov (United States)

    Cheng, T O; Holmes, D R

    1998-03-01

    The Inoue technique of percutaneous balloon mitral valvuloplasty, introduced in 1984, is a truly startling advance in cardiology in modern times. It is time to reeducate our colleagues that when they hear the opening snap in patients with mitral stenosis, they should automatically open these stenotic mitral valves with an Inoue balloon catheter rather than submit these patients to surgical correction. PMID:9514461

  15. Amputation-Free Survival after Crural Percutaneous Transluminal Angioplasty for Critical Limb Ischemia

    DEFF Research Database (Denmark)

    Strøm, M; Konge, L; Lönn, L; Schroeder, T V; Rørdam, P

    2015-01-01

    BACKGROUND AND AIM: To evaluate the amputation-free survival after below the knee percutaneous transluminal angioplasty in a consecutive group of patients with critical ischemia of the lower extremity. MATERIALS AND METHODS: A total of 70 consecutive patients with critical ischemia were treated......-up clinical examinations were performed within 6 weeks and after 1 year. All medical records were crosschecked with the national vascular registry ensuring a valid 1-year status in 97% of the patients. RESULTS: A total of 15 major amputations were performed during follow-up, with 11 amputations performed...... within the first year. Complications after percutaneous transluminal angioplasty were rare. Cumulative mortality after 1 and 2 years was 22% and 34%, respectively. Amputation-free survival at 1 and 2 years of follow-up was 68% and 58%, respectively. There were no association between known risk factors...

  16. Spontaneous Coronary Dissection: “Live Flash” Optical Coherence Tomography Guided Angioplasty

    Science.gov (United States)

    Bento, Angela Pimenta; Fernandes, Renato Gil dos Santos Pinto; Neves, David Cintra Henriques Silva; Patrício, Lino Manuel Ribeiro; de Aguiar, José Eduardo Chambel

    2016-01-01

    Optical Coherence tomography (OCT) is a light-based imaging modality which shows tremendous potential in the setting of coronary imaging. Spontaneous coronary artery dissection (SCAD) is an infrequent cause of acute coronary syndrome (ACS). The diagnosis of SCAD is made mainly with invasive coronary angiography, although adjunctive imaging modalities such as computed tomography angiography, IVUS, and OCT may increase the diagnostic yield. The authors describe a clinical case of a young woman admitted with the diagnosis of ACS. The ACS was caused by SCAD detected in the coronary angiography and the angioplasty was guided by OCT. OCT use in the setting of SCAD has been already described and the true innovation in this case was this unique use of OCT. The guidance of angioplasty with live and short images was very useful as it allowed clearly identifying the position of the guidewires at any given moment without the use of prohibitive amounts of contrast. PMID:26989520

  17. Popliteal artery thrombosis in a patient with Cogan syndrome: Treatment with thrombolysis and percutaneous transluminal angioplasty

    International Nuclear Information System (INIS)

    A 31-year-old woman with Cogan syndrome (a rare form of systemic vasculitis) was evaluated for a cold, painful left foot with diminished pulses. Arteriography demonstrated thrombosis of the left popliteal artery with evidence of vasculitis. Thrombolytic therapy was begun with initial success but eventual rethrombosis. After reinitiating thrombolytic therapy combined with intraarterial vasodilator therapy, successful angioplasty was performed with sustained results, at 6-month follow-up

  18. [Comparison of the results of coronary angioplasty and stenting during one year following surgery].

    Science.gov (United States)

    Simonenko, V B; Seĭdov, V G; Zakharov, S V; Evsiukov, V V; Liubchuk, I V

    2007-01-01

    The purpose of the study was to compare long-term results of angioplasty and coronary arterial stenting (CAS) depending on the initial degree of coronary arterial (CA) lesion according to morphological stenosis classification, as well as to evaluate the influence of re-stenosis on myocardial contractility dynamics, anginal recurrence rate, and exercise tolerance. The subjects, 228 men after angioplasty and 184 men after CAS with wire stents without drug coating, were included in the study between 1989 and 2005. Coronarography was repeated in 358 patients one year after surgery. The patients were divided into two groups. The first group consisted of 161 patients, to who 180 stents were implanted. The second group consisted of 197patients, in who 226 angioplasty procedures were performed. Data were processed using standard variational statistical methods, i.e. the calculation of mean values and standard deviation. Statistical calculations were carried out using Analysis ToolPak- VBA software of Microsoft Excel 2000. The study found that one year after either intervention the number of patients without anginal symptoms fell significantly compared with this number during the in-hospital period. In group 2 the frequency of restenosis was higher and the number of patients with anginal symptoms was significantly bigger than in group 1; the number of asymptomatic patients was significantly bigger in group 1. Initial morphological characteristics of CA lesion had a significant effect on the long-term frequency of restenosis following endovascular treatment. Restenosis was 2 to 2.5 times more frequent in patients with C type CA lesion vs. patients with A type regardless the method of endovascular intervention. The results of the study demonstrate the importance of taking into account initial morphological characteristics of CA lesion; CAS is more preferable than angioplasty, especially in patients with C type CA lesion. PMID:17520881

  19. Comparison between primary angioplasty and thrombolytic therapy on erectile dysfunction after acute ST elevation myocardial infarction

    OpenAIRE

    Akdemir, Ramazan; Karakurt, Özlem; Orcan, Salih; Karakoyunlu, Nihat; Mucahit Balci, Mustafa; SAĞNAK, Levent; Ersoy, Hamit; Bulent Vatan, Mehmet; Kilic, Harun; Yeter, Ekrem

    2012-01-01

    Acute ST elevation myocardial infarction has high mortality and morbidity rates. The majority of patients with this condition face erectile dysfunction in addition to other health problems. In this study, we aimed to investigate the effects of two different reperfusion strategies, primary angioplasty and thrombolytic therapy, on the prevalence of erectile dysfunction after acute myocardial infarction. Of the 71 patients matching the selection criteria, 45 were treated with primary coronary an...

  20. Results of Primary Angioplasty in a Reference Center: in-Hospital Outcomes

    OpenAIRE

    Ramos, R.; Patrício, L; Bernardes, L; Cacela, D; Sousa, L.; Fiarresga, A; Gonçalves, JM; Toste, A; Lousinha, A; Oliveira, JA; Ferreira, ML; Andreozzi, V; Cruz Ferreira, R

    2009-01-01

    INTRODUCTION: Primary angioplasty is accepted as the preferred treatment for acute myocardial infarction in the first 12 hours. However, outcomes depend to a large extent on the volume of activity and experience of the center. Continuous monitoring of methods and results obtained is therefore crucial to quality control. OBJECTIVE: To describe the demographic, clinical and angiographic characteristics as well as in-hospital outcomes of patients undergoing primary PCI in a high-volume Portu...

  1. Immediate versus deferred coronary angioplasty in non-ST-segment elevation acute coronary syndromes

    OpenAIRE

    Riezebos, R.K.; Ronner, E.; Bals, ter, E.; Slagboom, T.; Smits, P.C.; Berg, ten, A.J.W.M.; Kiemeneij, F.; Amoroso, G.; Patterson, M S; Suttorp, M J; Tijssen, J.G.P.; Laarman, G.J.

    2009-01-01

    BACKGROUND: The field of acute coronary syndromes is characterised by an increasing tendency towards early invasive catheter-based diagnostics and therapeutics-a practice based on observational and retrospective data. OBJECTIVE: To compare immediate versus deferred angioplasty in patients with non-ST-segment elevation acute coronary syndromes (NSTE-ACS). METHODS: A randomised, prospective multicentre trial was performed in patients admitted with NSTE-ACS, eligible for percutaneous coronary in...

  2. The use of abciximab associated with primary angioplasty for treating acute myocardial infarction

    OpenAIRE

    Manuel Lisandro Hernández Brito; Newton F. Stadler de Souza Filho; Álvaro Vieira Moura; Luiz Augusto Lavalle; Rubens Zenobio Darwich; Marisa Leal; Eva Cantalejo Munhoz

    2002-01-01

    OBJECTIVE: To assess the benefit resulting from the use of abciximab associated with primary angioplasty. The following parameters were analyzed in-hospital, at 30 days, and 6 months: (a) flow in the culprit artery; (b) ventricular function; (c) combined outcome of death, acute myocardial infarction, and aditional revascularization. METHODS: From November 1997 to June 1999, a longitudinal nonrandomized study with historical data of 137 patients with acute myocardial infarction within the firs...

  3. The use of abciximab associated with primary angioplasty for treating acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Brito Manuel Lisandro Hernández

    2002-01-01

    Full Text Available OBJECTIVE: To assess the benefit resulting from the use of abciximab associated with primary angioplasty. The following parameters were analyzed in-hospital, at 30 days, and 6 months: (a flow in the culprit artery; (b ventricular function; (c combined outcome of death, acute myocardial infarction, and aditional revascularization. METHODS: From November 1997 to June 1999, a longitudinal nonrandomized study with historical data of 137 patients with acute myocardial infarction within the first 12 hours. Patients undergoing primary angioplasty and were divided into 2 groups: those receiving (A abciximab (26 or (B conventional therapy (111. TIMI flow and regional ventricular function estimated by the standard deviation (SD/chordis index were analyzed. RESULTS: At the end of angioplasty, TIMI 3 flow was observed in 76.9% and 83.8% of the patients in groups A and B, respectively (P=0.58. In the reevaluation, patients with TIMI flow <3 showed a 100% improvement in group A and a 33% in group B (P<0.0001. A significant improvement (P<0.0001 in regional ventricular function, by SD/chordis index, occurred in each group; no significant difference between groups however, was observed (29.9% x 20.2%; P=0.58. A nonsignificant reduction in the combined outcome in the in-hospital phase (3.85% A x 9.0% B; P=0.34 and on the 30th day (4.0% x 12.0%; P=0.22 was observed in group A. CONCLUSION: Abciximab improved blood flow. Primary angioplasty improved regional ventricular function independent of antithrombotic therapy. Abciximab showed a trend toward reducing the combined outcome in the in-hospital phase and on the 30th day.

  4. Significance of Cardiac Troponin T Release in Detecting Minor Myocardial Injury After Percutaneous Transluminal Coronary Angioplasty

    OpenAIRE

    ALPER, Gülinnaz

    1999-01-01

    Cardiac Troponin T (TnT) is a regulatory contractile protein not normally found in blood. Its detection in the circulation has been shown to be a sensitive and specific marker for myocardial cell damage. This study was designed to evaluate the diagnostic efficiency of TnT enzyme immunoassay in detecting myocardial damage in patients with stable angina pectoris undergoing visually successful percutaneous transluminal coronary angioplasty (PTCA) and to compare this newly developed test with t...

  5. Noninvasive Positive Pressure Ventilation against Reperfusion Pulmonary Edema following Percutaneous Transluminal Pulmonary Angioplasty

    OpenAIRE

    Kiyoshi Moriyama; Sayuri Sugiyama; Koji Uzawa; Mariko Kotani; Toru Satoh; Tomoko Yorozu

    2011-01-01

    A 69-year-old man with chronic thromboembolic pulmonary hypertension (CTEPH) was on amblatory oxygen inhalation therapy (3 L/min) and scheduled for percutaneous transluminal pulmonary angioplasty (PTPA). The patient's New York Heart Association functional status was class III with recent worsening of dyspnea and apparent leg edema. Transthoracic echocardiography revealed right ventricular enlargement with mean pulmonary artery pressure of 42 mmHg. After PTPA, he was complicated with postopera...

  6. Vibrational angioplasty in recanalization of chronic femoropopliteal arterial occlusions: Single center experience

    International Nuclear Information System (INIS)

    Purpose: This prospective study aims to present the overall success rate, safety and long-term outcome of vibrational angioplasty technique, in the treatment of chronic total femoropopliteal occlusions in our institute. Methods: Between October 2000 and December 2008, patients with chronic total femoropoliteal arterial occlusions, treated with vibrational angioplasty during the same session after a failed attempt with conventional recanalization technique, were included. Patient's follow up included serial ankle-brachial index measurements and arterial duplex ultrasound examinations at 1, 3, 6, 12, 24, 36 and 48 months. Results: Twenty-seven patients (16 males and 11 females) and twenty-eight lesions were included in our study. Twenty-five lesions (89.3%) were successfully recanalized. Pain relief was noticed in twenty-one cases. From ten lesions with tissue loss (ulcer or gangrene) in successfully recanalized occlusions, six healed without major, or minor amputation. One non-healing amputation stump was healed after recanalization, without further complications. Four limbs underwent amputation (one minor and three major) despite successful recanalization, however all had an excellent healing of the amputation stump without further complications. The Kaplan–Meier test demonstrated 90%, 85% and 70% amputation-free survival rate at 12, 24 and 36 months, respectively. No major or minor complications were encountered. Conclusions: Vibrational angioplasty is a safe, effective and durable endovascular technique for the treatment of chronic total occlusions in patients with limb ischemia that would be difficult to recanalize using conventional intraluminal techniques

  7. Transluminal stent-assisted angioplasty for the vertebro-basilar ischemia

    International Nuclear Information System (INIS)

    Objective: To study the safety and efficacy of transluminal stent-assisted angioplasty in the treatment of vertebro-basilar ischemia. Methods: Between June 2002 and April 2002, the transluminal stent-assisted angioplasty was performed in 16 patients with symptomatic vertebro-basilar artery stenosis. Results: The vertebral artery stenosis with contralateral stenosis or occlusion were found in 7 patients, unilateral significant stenosis of the dominant vertebral artery in 7, symptomatic basilar artery stenosis in 1, and the significant unilateral lesion of a non-dominant VA. When symptoms indicated ischemia in the ipsilateral posterior cerebellar artery (PICA) in another. The successful rate of stent implantation was 100% without any serious complications. The degree of stenosis was significantly improved from 73.2% to 5.1%, P < 0.01. Within mean follow-up of 4.4 months (ranged from 1 month to 12 months), there was no neurologic complication. Conclusions: Preliminary results suggest that transluminal stent-assisted angioplasty in the treatment of vertebro-basilar ischemia to be a safe and effective. Long-term angiographic and clinical follow-up for monitoring a larger number of patients is needed

  8. Percutaneous trans-ulnar artery approach for coronary angiography and angioplasty; A case series study

    Science.gov (United States)

    Roghani-Dehkordi, Farshad; Hadizadeh, Mahmood; Hadizadeh, Fatemeh

    2015-01-01

    BACKGROUND Coronary angiography is the gold standard method for diagnosis of coronary heart disease and usually performed by femoral approach that has several complications. To reduce these complications, upper extremity approach is increasingly used and is becoming preferred access site by many interventionists. Although radial approach is relatively well studied, safety, feasibility and risk of applying ulnar approach in not clearly known yet. METHODS We followed 97 patients (man = 56%, mean ± standard deviation of age = 57 ± 18) who had undergone coronary angiography or angioplasty via ulnar approach for 6-10 months and recorded their outcomes. RESULTS In 97 patients out of 105 ones (92.38%), procedure through ulnar access were successfully done. Unsuccessful puncture (3 patients), wiring (2 patients), passing of sheet (2 patients), and anatomically unsuitable ulnar artery (1 patient) were the reasons of failure. In 94 patients (89.52%), the angiography and angioplasty was done without any complications. Five patients (5.1%) hematoma and 11 patients (11%) experienced low-grade pain that resolved with painkiller. No infection, amputation or need for surgery was reported. CONCLUSION This study demonstrated that ulnar access in our patients was a safe and practical approach for coronary angiography or angioplasty, without any major complication. Bearing in mind its high success rate, it can be utilized when a radial artery is not useful for the catheterization and in cases such as prior harvesting of the radial artery (in prior coronary artery bypass grafting). PMID:26715936

  9. Vibrational angioplasty in recanalization of chronic femoropopliteal arterial occlusions: Single center experience

    Energy Technology Data Exchange (ETDEWEB)

    Kapralos, Ioannis, E-mail: jkapgr@yahoo.gr [251 Hellenic Air Force General Hospital, Athens (Greece); Kehagias, Elias, E-mail: eliaskmd@yahoo.gr [Interventional Radiology Unit, Department of Radiology, Faculty of Medicine, University of Crete, Heraklion, Crete (Greece); Ioannou, Christos, E-mail: ioannou@med.uoc.g [Faculty of Medicine, University of Crete, Heraklion, Crete (Greece); Bouloukaki, Izolde, E-mail: izolthi@gmail.com [Interventional Radiology Unit, Department of Radiology, Faculty of Medicine, University of Crete, Heraklion, Crete (Greece); Kostas, Theodoros, E-mail: kostasth@mailbox.gr [Faculty of Medicine, University of Crete, Heraklion, Crete (Greece); Katsamouris, Asterios, E-mail: asterios@med.uoc.gr [Faculty of Medicine, University of Crete, Heraklion, Crete (Greece); Tsetis, Dimitrios, E-mail: tsetis@med.uoc.gr [Interventional Radiology Unit, Department of Radiology, Faculty of Medicine, University of Crete, Heraklion, Crete (Greece)

    2014-01-15

    Purpose: This prospective study aims to present the overall success rate, safety and long-term outcome of vibrational angioplasty technique, in the treatment of chronic total femoropopliteal occlusions in our institute. Methods: Between October 2000 and December 2008, patients with chronic total femoropoliteal arterial occlusions, treated with vibrational angioplasty during the same session after a failed attempt with conventional recanalization technique, were included. Patient's follow up included serial ankle-brachial index measurements and arterial duplex ultrasound examinations at 1, 3, 6, 12, 24, 36 and 48 months. Results: Twenty-seven patients (16 males and 11 females) and twenty-eight lesions were included in our study. Twenty-five lesions (89.3%) were successfully recanalized. Pain relief was noticed in twenty-one cases. From ten lesions with tissue loss (ulcer or gangrene) in successfully recanalized occlusions, six healed without major, or minor amputation. One non-healing amputation stump was healed after recanalization, without further complications. Four limbs underwent amputation (one minor and three major) despite successful recanalization, however all had an excellent healing of the amputation stump without further complications. The Kaplan–Meier test demonstrated 90%, 85% and 70% amputation-free survival rate at 12, 24 and 36 months, respectively. No major or minor complications were encountered. Conclusions: Vibrational angioplasty is a safe, effective and durable endovascular technique for the treatment of chronic total occlusions in patients with limb ischemia that would be difficult to recanalize using conventional intraluminal techniques.

  10. Matrix metalloproteinase 9 level as an indicator for restenosis following cervical and intracranial angioplasty and stenting

    Directory of Open Access Journals (Sweden)

    Jun-peng Liu

    2015-01-01

    Full Text Available Cervical and intracranial angioplasty and stenting is an effective and safe method of reducing the risk of ischemic stroke, but it may be affected by in-stent restenosis. The present study investigated serum level of matrix metalloproteinase 9 as a predictor of restenosis after 40 patients underwent cervical and/or intracranial angioplasty and stenting. Results showed that restenosis occurred in 30% (3/10 of patients when the serum level of matrix metalloproteinase 9 at 3 days after surgery was 2.5 times higher than preoperative level. No restenosis occurred when the serum level of matrix metalloproteinase 9 at 3 days after surgery was not 2.5 times higher than preoperative level. Restenosis occurred in 12% (2/17 of patients when the serum level of matrix metalloproteinase 9 was higher than preoperative level for more than 30 days after surgery, but only occurred in 4% (1/23 of patients when the serum level of matrix metalloproteinase 9 was higher than preoperative level for less than 30 days after surgery. However, the differences observed were not statistically significant (P > 0.05. Experimental findings indicate that when the serum level of matrix metalloproteinase 9 is 2.5 times higher than preoperative level at 3 days after cervical and intracranial angioplasty and stenting, it may serve as a predictor of in-stent restenosis.

  11. Microgravity combustion experiment using high altitude balloon.

    Science.gov (United States)

    Kan, Yuji

    In JAXA, microgravity experiment system using a high altitude balloon was developed , for good microgravity environment and short turn-around time. In this publication, I give an account of themicrogravity experiment system and a combustion experiment to utilize the system. The balloon operated vehicle (BOV) as a microgravity experiment system was developed from 2004 to 2009. Features of the BOV are (1) BOV has double capsule structure. Outside-capsule and inside-capsule are kept the non-contact state by 3-axis drag-free control. (2) The payload is spherical shape and itsdiameter is about 300 mm. (3) Keep 10-4 G level microgravity environment for about 30 seconds However, BOV’s payload was small, and could not mount large experiment module. In this study, inherits the results of past, we established a new experimental system called “iBOV” in order toaccommodate larger payload. Features of the iBOV are (1) Drag-free control use for only vertical direction. (2) The payload is a cylindrical shape and its size is about 300 mm in diameter and 700 mm in height. (3) Keep 10-3-10-4 G level microgravity environment for about 30 seconds We have "Observation experiment of flame propagation behavior of the droplets column" as experiment using iBOV. This experiment is a theme that was selected first for technical demonstration of iBOV. We are conducting the flame propagation mechanism elucidation study of fuel droplets array was placed at regular intervals. We conducted a microgravity experiments using TEXUS rocket ESA and drop tower. For this microgravity combustion experiment using high altitude balloon, we use the Engineering Model (EM) for TEXUS rocket experiment. The EM (This payload) consists of combustion vessel, droplets supporter, droplets generator, fuel syringe, igniter, digital camera, high-speed camera. And, This payload was improved from the EM as follows. (1) Add a control unit. (2) Add inside batteries for control unit and heater of combustion

  12. A complex dissected chronic occlusion: targeted balloon dilatation of false lumen to access true lumen, combined localized subintimal tracking and reentry, parallel wire, contralateral injection and a useful antegrade lumen re-entry technique

    Directory of Open Access Journals (Sweden)

    James W. Tam

    2012-02-01

    Full Text Available Chronic total occlusion (CTO angioplasty is one of the most challenging procedures remaining for the interventional operator. Recanalizing CTOs can improve exercise capacity, symptoms, left ventricular function and possibly reduce mortality. Multiple strategies such as escalating wire, parallel wire, seesaw, contralateral injection, subintimal tracking and re-entry (STAR, retrograde wire techniques (controlled antegrade retrograde subintimal tracking, CART, reverse CART, confluent balloon, rendezvous in coronary, and other techniques have all been described. Selection of the most appropriate approach is based on assessment of vessel course, length of occluded segment, presence of bridging collaterals, presence of bifurcating side branches at the occlusion site, and other variables. Today, with significant operator expertise and the use of available techniques, the literature reports a 50-95% success rate for recanalizing CTOs.

  13. A Survey of Titan Balloon Concepts and Technology Status

    Science.gov (United States)

    Hall, Jeffery L.

    2011-01-01

    This paper surveys the options for, and technology status of, balloon vehicles to explore Saturn's moon Titan. A significant amount of Titan balloon concept thinking and technology development has been performed in recent years, particularly following the spectacular results from the descent and landing of the Huygens probe and remote sensing observations by the Cassini spacecraft. There is widespread recognition that a balloon vehicle on the next Titan mission could provide an outstanding and unmatched capability for in situ exploration on a global scale. The rich variety of revealed science targets has combined with a highly favorable Titan flight environment to yield a wide diversity of proposed balloon concepts. The paper presents a conceptual framework for thinking about balloon vehicle design choices and uses it to analyze various Titan options. The result is a list of recommended Titan balloon vehicle concepts that could perform a variety of science missions, along with their projected performance metrics. Recent technology developments for these balloon concepts are discussed to provide context for an assessment of outstanding risk areas and technological maturity. The paper concludes with suggestions for technology investments needed to achieve flight readiness.

  14. Boston's balloon dilatation for treatment of cardiac achalasia

    International Nuclear Information System (INIS)

    Objective: To review and summarize effectiveness and method of the Boston's balloon dilation in cardiac achalasia. Methods: The intensified guide wire was inserted into stomach through mouth cavity under TV control. The Boston's balloon was inserted to the cardiac stricture through the guide wire and dilatated with 15% contrast medium with to a maximum diameter for five minutes and then the balloon was dilatated again for 3-5 minutes, all together for 3-4 times. The severe stricture must be pre-dilatated with 20-25 mm diameter balloon. Results: The balloon insertion was technically successful in all 26 patients. The once success of balloon dilation was achieved in 24 patients and twice in other 2. Follow-up time was from 2 weeks to 31 months (mean 10.6 months). Recurrent stenosis had not occurred in all patients. Remission rate of dysphagia was 100%. Esophageal reflux occurred in 3 patients. Conclusions: The Boston's balloon dilatation is simple and effective for treatment of cardiac achalasia. The method sometimes may replace surgical procedure

  15. Procoagulant platelet balloons: evidence from cryopreparation and electron microscopy.

    Science.gov (United States)

    Hess, M W; Siljander, P

    2001-05-01

    Visualisation of the procoagulant transformation of human platelets has recently become possible through use of an in vitro approach combined with fluorescence and phase contrast microscopy. Here, we extended these studies to the ultrastructural level by employing both rapid freezing/freeze-substitution and conventional ambient-temperature chemical fixation for transmission and scanning electron microscopy. Procoagulant transformation was only inducible by adhering platelets to collagen fibrils or to the collagen-related peptide and exposing them to physiological extracellular Ca2+ levels. Under these conditions prominent, 2- to 4-micron-wide balloon-like structures were regularly observed, regardless of the specimen fixation protocol. In strong contrast to normal platelets in their vicinity, the balloons' subcellular architecture proved remarkably poor: dilute cytoplasm, no cytoskeleton, only a few, randomly distributed organelles and/or their remnants. Cryofixed balloons displayed intact and smooth surfaces whereas conventional specimen processing caused plasma membrane perforations and shrinkage of the balloons. Our results clearly show that neither the balloons themselves, nor their simple ultrastructure reflect fixation artefacts caused by inadequate membrane stabilisation. The balloons are interpreted as to be transformed and/or fragmented procoagulant platelets. Thus, the generation of balloons represents a genuine, final stage of platelet ontogenesis, presumably occurring alternatively to aggregate formation. PMID:11449892

  16. Graph-Based Path-Planning for Titan Balloons

    Science.gov (United States)

    Blackmore, Lars James; Fathpour, Nanaz; Elfes, Alberto

    2010-01-01

    A document describes a graph-based path-planning algorithm for balloons with vertical control authority and little or no horizontal control authority. The balloons are designed to explore celestial bodies with atmospheres, such as Titan, a moon of Saturn. The algorithm discussed enables the balloon to achieve horizontal motion using the local horizontal winds. The approach is novel because it enables the balloons to use arbitrary wind field models. This is in contrast to prior approaches that used highly simplified wind field models, such as linear, or binary, winds. This new approach works by discretizing the space in which the balloon operates, and representing the possible states of the balloon as a graph whose arcs represent the time taken to move from one node to another. The approach works with arbitrary wind fields, by looking up the wind strength and direction at every node in the graph from an arbitrary wind model. Having generated the graph, search techniques such as Dijkstra s algorithm are then used to find the set of vertical actuation commands that takes the balloon from the start to the goal in minimum time. In addition, the set of reachable locations on the moon or planet can be determined.

  17. Assessment of "silent" restenosis and long-term follow-up after successful angioplasty in single vessel coronary artery disease: the value of quantitative exercise electrocardiography and quantitative coronary angiography

    NARCIS (Netherlands)

    G-J. Laarman (GertJan); H.E. Luijten; L.G.P.M. van Zeyl; K.J. Beatt (Kevin); J.G.P. Tijssen (Jan); P.W.J.C. Serruys (Patrick); P.J. de Feyter (Pim)

    1990-01-01

    textabstractExercise electrocardiographic (ECG) testing during follow-up after coronary angioplasty is widely applied to evaluate the efficacy of angioplasty, even in asymptomatic patients. One hundred forty-one asymptomatic patients without previous myocardial infarction underwent quantitative exer

  18. Ballooning of CANDU pressure tubes. Model assessment

    International Nuclear Information System (INIS)

    The transient creep equations used to analyze the possible ballooning and failure of Zr-2.5% Nb pressure tubes during a loss-of-coolant accident (LOCA) were developed and verified using as-received Zr-2.5% Nb pressure tube material. But in a CANDU reactor, the pressure tubes absorb deuterium and are exposed to a continuous neutron fluence. Consequently, a literature survey was done to determine how irradiation damage and deuterium might affect the creep rate and ductility of Zr-2.5% Nb pressure tubes in the temperature range from 600 to 800 degrees C. It was found that irradiation damage, dissolved deuterium and deuteride blisters could possibly affect the creep rate and ductility of ZR-2.5% Nb pressure tubes in this temperature range, but deuteride platelets are expected to have little effect. Further tests are required to determine the effect of irradiation damage and deuterium on the creep rate and ductility of pressure tubes

  19. Balloon brachytherapy: how I do it

    International Nuclear Information System (INIS)

    To describe the technical aspects of insertion of MammoSite Radiation System, cosmetic issues, patients selection for the procedure and their satisfaction. Seventy patients underwent brachytherapy after insertion of the MammoSite catheter and received a boost HDR totaling 1500 cGy in six fractions over a three day period. Each patient then received 5 weeks of external beam radiotherapy to the whole breast. Only T1-2 patients were treated. All patients had excellent cosmetic results. The complications (minimal skin erythema, hematoma, balloon leak, seroma, were minimal. The safety and effectiveness of the MammoSite Radiation Therapy System as a replacement for whole breast irradiation in the treatment of breast cancer has not yet been established. (author)

  20. Long-term results after primary infrapopliteal angioplasty for limb ischemia; Langzeitergebnisse nach Ballonangioplastie kruraler Arterien

    Energy Technology Data Exchange (ETDEWEB)

    Alfke, H. [Klinikum Luedenscheid (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Marburg Univ. (Germany). Klinik fuer Strahlendiagnostik; Vannucchi, A. [Marburg Univ. (Germany). Klinik fuer Strahlendiagnostik; Froelich, J.J. [Marburg Univ. (Germany). Klinik fuer Strahlendiagnostik; Klinikum Bad Hersfeld (Germany). Klinik fuer Radiologie und Nuklearmedizin; El-Sheik, M.; Wagner, H.J. [Marburg Univ. (Germany). Klinik fuer Strahlendiagnostik; Vivantes-Klinikum im Friedrichshain (Germany). Inst. fuer Radiologie und Interventionelle Therapie

    2007-08-15

    Purpose: To evaluate the technical success rate, procedure-related complications, and clinical long-term results for patients who underwent infrapopliteal angioplasty. Materials and Methods: We retrospectively evaluated all patients who underwent infrapopliteal angioplasty to treat critical chronic limb ischemia or severe claudication from 1/1997 to 12/1999. We excluded patients with acute (< 2 weeks) limb ischemia. Procedure-related data were prospectively documented in a database and analyzed with a focus on the technical success rate and procedure-related complications. In addition all clinical documents were analyzed, and a follow-up examination was performed or telephone interviews were conducted with patients, relatives and referring doctors for follow-up. The primary end points were the limb salvage rate and patient survival rate. The secondary end points included the complication rate, technical success rate, and walking distance. Results: 112 patients with a mean age of 72 years (41 women, 71 men) underwent crural angioplasty on 121 limbs. Four patients suffered from severe claudication (Rutherford category 3) and all others had critical chronic limb ischemia (category 4 to 6). The complication rate was 2.7 %. The technical success rate was 92 %. The ankle brachial index increased from 0.59 to 0.88. The mean walking distance increased significantly from 52 {+-} 66 to 284 {+-} 346 meters at the time of follow-up. The limb salvage rate was 83.6 % after one year and 81.1 % after three years. The mean survival rate according to Kaplan-Meier was 79.4 %, 69.2 %, and 54.2 % at 1, 2, and 3 years, respectively. Patients with at least one patent run-off vessel after angioplasty had a significantly better limb salvage rate. Diabetes was not a risk factor for limb salvage. Conclusion: Infrapopliteal angioplasty shows a high technical success rate with an acceptable complication rate. The clinical long-term success seems favorable if a least one open run-off vessel was

  1. Migration of Bakri balloon through an unsuspected uterine perforation during the treatment of secondary postpartum hemorrhage.

    Science.gov (United States)

    Leparco, Soizic; Viot, Alexandre; Benachi, Alexandra; Deffieux, Xavier

    2013-06-01

    The current case describes an unreported complication of Bakri balloon placement: the migration of the Bakri balloon to the broad ligament through an unsuspected uterine rupture. Finally, a hysterectomy had been required. The Bakri balloon may be involuntary introduced in an unexpected uterine rupture, even if the balloon is placed with ultrasound guidance. PMID:23470856

  2. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Pretolesi, F.; Derchi, L.E. [Dept. of Radiology, University of Genoa (Italy); Redaelli, G.; Papagni, L. [IRCCS, Ist. Auxologico Italiano, Milan (Italy)

    2001-04-01

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  3. Effect of poloidally asymmetric sheared flow on resistive ballooning turbulence

    International Nuclear Information System (INIS)

    The shear flow induced through the Reynolds stress tensor by turbulence with ballooning character is poloidally asymmetric. For circular cross section tokamak plasmas, its main component is the (m=1, n=0). The effect of such a sheared flow on both linear and nonlinear instability is analyzed. Its effect on the linear stability properties of resistive ballooning modes is compared with the effect of poloidally symmetric sheared flows. It is shown that asymmetry in the flow does not reduce its effectiveness in stabilizing the linear resistive ballooning modes. It is also effective in reducing the turbulence level and decreasing the turbulence induced diffusivities. copyright 1999 American Institute of Physics

  4. An investigation of electrostatically deposited radionuclides on latex balloons

    International Nuclear Information System (INIS)

    Use of Canadian Nuclear Society (CNS) education material for a community science education event to promote science awareness, science culture and literacy (Science Rendezvous 2011) lead to investigation of observed phenomena. Experiments are done on balloons that are electrostatically charged then left to collect particulate. Alpha spectroscopy was performed to identify alpha emitting radioisotopes present on the balloons. The time dependent behaviour of the activity was investigated. Additionally, the Alpha activity of the balloon was compared to Beta activity. The grounds for further investigations are proposed. (author)

  5. Validation of IASI ozone profiles, using balloon sounding data

    OpenAIRE

    Delcloo, Andy; Hurtmans, Daniel; Coheur, Pierre-François; Clerbaux, Cathy

    2011-01-01

    Here we present a validation study of IASI vertical ozone profiles. This has been done using balloon ozone sonde data, which have a vertical resolution of about 100 m and measures ozone from the surface up to an altitude of about 30 km. IASI vertical ozone profiles are given as partial ozone columns [in DU per layer] between varying pressure levels. To validate the satellite derived ozone layers with the balloon ozone sounding data we integrate the ozone measured by the balloon ozone sounding...

  6. Intragastric balloon for morbid obesity causing chronic gastric dilatation

    International Nuclear Information System (INIS)

    We describe the radiographic findings observed in a morbidly obese and diabetic patient with an intragastric air-filled balloon introduced as a therapeutic measure to reduce food intake. The balloon was associated with chronic gastric dilatation and had to be removed 3 months after insertion. However, together with diet and behavioural therapy, it proved effective in reducing body weight and ameliorating glycaemic control. Although rarely used, intragastric balloons for the treatment of morbid obesity are still encountered in radiological practice. Radiologists must be able to recognize them and to understand their complications. (orig.)

  7. Results of the first EUSO-Balloon flight

    Science.gov (United States)

    Miyamoto, H.; Bertaina, M.; JEM-EUSO Collaboration

    2016-05-01

    EUSO-Balloon, a balloon-borne diffractive fluorescence telescope, was launched by the French Space Agency ONES from the Timmins base in Ontario (Canada) on August 25th in 2014. After reaching the floating altitude of about 38 km, EUSO-Balloon imaged the UV background for more than 5 hours before descending to ground using the key technologies of JEM-EUSO. A detailed and precise measurement of the UV background in different atmospheric and ground conditions was achieved. The instrument proved the capability of detecting Extensive Air Showers (EAS) by observing laser tracks with similar characteristics. This contribution will summarise the first results obtained concerning all the topics described above.

  8. An investigation of electrostatically deposited radionuclides on latex balloons

    Energy Technology Data Exchange (ETDEWEB)

    Price, T.; Caly, A., E-mail: Terry.Price@gmail.com [Univ. of Ontario Inst. of Technology, Oshawa, Ontario (Canada)

    2012-07-01

    Use of Canadian Nuclear Society (CNS) education material for a community science education event to promote science awareness, science culture and literacy (Science Rendezvous 2011) lead to investigation of observed phenomena. Experiments are done on balloons that are electrostatically charged then left to collect particulate. Alpha spectroscopy was performed to identify alpha emitting radioisotopes present on the balloons. The time dependent behaviour of the activity was investigated. Additionally, the Alpha activity of the balloon was compared to Beta activity. The grounds for further investigations are proposed. (author)

  9. Pharmacokinetic study of paclitaxel concentration and distribution in the iliac arterial wall after drug eluting balloon angioplasty: Atherosclerotic animal model study

    OpenAIRE

    Fernández Parra, María del Rocío; Laborda García, Alicia; Gregorio Ariza, Miguel Ángel de; Blas Giral, Ignacio de

    2013-01-01

    El uso de fármacos inhibidores de la proliferación celular para moderar la respuesta hipertrófica de la célula, a través de distintos dispositivos de liberación local, se ha convertido en la actualidad en un tratamiento de referencia. Se conocen algunos aspectos sobre el mecanismo de acción, farmacocinética, incluso en relación con los resultados clínicos, sin embargo, muchos otros siguen siendo desconocidos. Esta falta de conocimiento es más importante en lo referente a los balones liberador...

  10. Derivatives of the local ballooning growth rate with respect to surface label, field line label and ballooning parameter

    International Nuclear Information System (INIS)

    For comprehensive ballooning analysis in three-dimensional (stellarator) systems, an extensive set of ballooning eigenvalue calculations is generally required. For several applications, it is convenient to know how the local ballooning stability will change as a function of the surface label ψ, the field line label α and the angle-like ballooning parameter ηk. A particularly important application is in the ray tracing problem [Dewar and Glasser 1983], when results from the local ballooning analysis are extended to make predictions regarding global stability. This article presents an explicit method for calculating the derivatives of the ballooning eigenvalue with respect to (ψ, α,ηk). The required derivatives satisfy δλ = ∂λ/∂ψ|α,ηk δψ + ∂λ/∂α|ψ,ηk δα+ ∂λ/ ∂ηk| ψ,α δηk, (1) for infinitesimal variations δψ,δα and δηk. The method is an application of eigenvalue perturbation analysis. The ballooning equation, with eigenvalue λ and eigenfunction ξ, may be written ∂ηP∂ηξ + Qξ = λRξ, (2). A small change in (ψ, α, ηk) induces a change in the ballooning coefficients, and a corresponding variation in the ballooning eigenvalue. The eigenvalue derivatives are calculated ∂λ/∂ψ|α,ζ = ηδPψ∂ + δQψ - λδRψ|ξ> (3) where Pψ, Qψ, and Rψ are the changes in the coefficients due to a small change in ψ,with similar expressions for ∂λ/∂α and ∂λ/∂ηk. Preliminary results of ray-tracing calculations will be presented. (author)

  11. Low Cost Variable Conductance Heat Pipe for Balloon Payload Project

    Data.gov (United States)

    National Aeronautics and Space Administration — While continuously increasing in complexity, the payloads of terrestrial high altitude balloons need a thermal management system to reject their waste heat and to...

  12. Current status of intragastric balloon for obesity treatment

    Science.gov (United States)

    Kim, Seung Han; Chun, Hoon Jai; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Jeen, Yoon Tae

    2016-01-01

    Endoscopic bariatric therapy may be a useful alternative to pharmacological treatment for obesity, and it provides greater efficacy with lower risks than do conventional surgical procedures. Among the various endoscopic treatments for obesity, the intragastric balloon is associated with significant efficacy in body weight reduction and relief of comorbid disease symptoms. Anatomically, this treatment is based on gastric space-occupying effects that increase the feeling of satiety and may also affect gut neuroendocrine signaling. The simplicity of the intragastric balloon procedure may account for its widespread role in obesity treatment and its applicability to various degrees of obesity. However, advances in device properties and procedural techniques are still needed in order to improve its safety and cost-effectiveness. Furthermore, verification of the physiological outcomes of intragastric balloon treatment and the clinical predictive factors for treatment responses should be considered. In this article, we discuss the types, efficacy, safety, and future directions of intragastric balloon treatment. PMID:27350727

  13. Proposed techniques for launching instrumented balloons into tornadoes

    Science.gov (United States)

    Grant, F. C.

    1971-01-01

    A method is proposed to introduce instrumented balloons into tornadoes by means of the radial pressure gradient, which supplies a buoyancy force driving to the center. Presented are analytical expressions, verified by computer calculations, which show the possibility of introducing instrumented balloons into tornadoes at or below the cloud base. The times required to reach the center are small enough that a large fraction of tornadoes are suitable for the technique. An experimental procedure is outlined in which a research airplane puts an instrumented, self-inflating balloon on the track ahead of the tornado. The uninflated balloon waits until the tornado closes to, typically, 750 meters; then it quickly inflates and spirals up and into the core, taking roughly 3 minutes. Since the drive to the center is automatically produced by the radial pressure gradient, a proper launch radius is the only guidance requirement.

  14. 10 meter Sub-Orbital Large Balloon Reflector (LBR) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Besides serving as a launch vehicle, the carrier balloon provides a stable mount for the enclosed telescope. Looking up, the LBR will serve as a telescope. Looking...

  15. Isothermal pumping analysis for high-altitude tethered balloons

    OpenAIRE

    Kuo, Kirsty A.; Hunt, Hugh E.M.

    2015-01-01

    High-altitude tethered balloons have potential applications in communications, surveillance, meteorological observations and climate engineering. To maintain balloon buoyancy, power fuel cells and perturb atmospheric conditions, fluids could be pumped from ground level to altitude using the tether as a hose. This paper examines the pumping requirements of such a delivery system. Cases considered include delivery of hydrogen, sulfur dioxide (SO2) and powders as fluid-based slurries. Isothermal...

  16. Small Research Balloons in a Physics Course for Education Majors

    Science.gov (United States)

    Bruhweiler, F. C.; Verner, E.; Long, T.; Montanaro, E.

    2013-12-01

    At The Catholic Univ. of America, we teach an experimental physics course entitled Physics 240: The Sun-Earth Connection, which is designed for the undergraduate education major. The emphasis is on providing hands-on experience and giving the students an exciting experience in physics. As part of this course, in the Spring 2013 semester, we instituted a project to plan, build, launch, and retrieve a small (~1.3 kg) research balloon payload. The payload flown was a small GPS unit that sent its position to an Internet site, a small wide-angle high-resolution video camera, and an analog refrigerator thermometer placed in the field of view of the camera. All data were stored on the camera sim-card. Students faced the problems of flying a small research balloon in the congested, densely populated Northeast Corridor of the US. They used computer simulators available on the Web to predict the balloon path and flight duration given velocities for the Jet Stream and ground winds, as well as payload mass and amount of helium in the balloon. The first flight was extremely successful. The balloon was launched 140 km NW of Washington DC near Hagerstown, MD and touched down 10 miles (16 km) NW of York, PA, within 1.6 km of what was predicted. The balloon reached 73,000 ft (22,000 m) and the thermometer indicated temperatures as low as -70 degrees Fahrenheit (-57 C) during the flight. Further balloon flights are planned in conjunction with this course. Additional exercises and experiments will be developed centered around these flights. Besides learning that science can be exciting, students also learn that science is not always easily predictable, and that these balloon flights give an understanding of many of problems that go into real scientific space missions. This project is supported in part by an educational supplement to NASA grant NNX10AC56G

  17. Percutaneous Transhepatic Balloon Dilatation of Benign Biliary Strictures

    OpenAIRE

    Trambert, Jonathan J.; Bron, Klaus M.; Zajko, Albert B.; Starzl, Thomas E.; Iwatsuki, Shunzaburo

    1987-01-01

    Between February 1981 and June 1984, 15 patients with benign biliary strictures were treated with percutaneous transhepatic balloon dilatation. Three of these patients had received liver transplants. The treatment began with a course of balloon dilatation therapy, after which a stent catheter was left across the stricture. Six weeks later, after duct patency had been shown by cholangiography, the stent catheter was removed from all but two patients, both of whom had intrahepatic sclerosing ch...

  18. How to Inflate the Balloon Can Be Dangerous?

    OpenAIRE

    Yürümez, Yusuf; Küçük, Egemen; YAVUZ, Yücel; Eşme, Hıdır; SOLAK, Okan; Yücel, Murat

    2013-01-01

    Spontaneous pneumomediastinum is a quite rare clinical condition. A variety of reasons are responsible from etiology thats are increases intra-alveolar pressure and leading to rupture of alveoli. In this study 38-year-old male patient has been submitted that he has crackling sensation and pain in the neck region, hoarseness and shortness of breath two hours after inflating the balloon. Inflating the balloon that not included in the literature and appear to be innocent should be included among...

  19. Balloon observations of solar ultraviolet irradiance at solar minimum

    International Nuclear Information System (INIS)

    Balloon observations of solar irradiance between 200 and 240 nm have been performed in 1976 and 1977 corresponding to minimum conditions of solar activity. Ultraviolet spectra have been recorded for different zenith angles at an altitude of 41 km by means of a spectrometer with a spectral bandpass of 0.4 nm. Solar irradiances at 1 a.u. confirm previous values obtained by balloon. They are compared with other measurements and discussed in terms of possible long-term variability. (author)

  20. Development of a tiny tandem balloon system for atmospheric observation

    Science.gov (United States)

    Saito, Yoshitaka; Yamada, Kazuhiko; Fujiwara, Masatomo

    2016-07-01

    A tandem balloon system with a combination of a zero-pressure balloon on top and a super-pressure balloon on the bottom has a unique trajectory characteristic, with different flight altitudes between day and night and thus with ascending and descending motions at dawn and dusk, respectively. This characteristic provides a unique opportunity to explore the atmosphere, e.g., the upper tropospheric and lower stratospheric region with cross-tropopause measurements twice a day. We started development of a tiny tandem balloon system using a 10 m^{3} super-pressure balloon and a 100 m^{3} zero-pressure balloon, with a capability of carrying 3 kg of payload. One of the scientific targets is to measure water vapor, cloud particles, and temperature around the tropical tropopause which is the entry point of the stratospheric and mesospheric meridional circulation. For the data transfer, the iridium satellite communication module, SBD9603 is used. In this paper, the current status of the development will be reported.

  1. Burn Injury Arise From Flying Balloon Toys

    Directory of Open Access Journals (Sweden)

    Yalcin Kulahci

    2007-08-01

    Full Text Available Many of peoples are faced minor or major burn injuries in their life. Even the most widespread burn cause is flame injuries, too different burn cause pointed out in literature like Acetylen burns. The cases which imply in literature, mostly causes from explosion of high pressure acetylene tube, metal oxygene patch flame or carbide lamp using from cave explorers. An interesting acetylene burn cause in Turkey was publised by the authors. This cases was to come into being from flying toy balloons flame. 80 person was injured from flying toy ballons flame in a meeting in 2002. Although this potential risks of acetylene, helium have not any of some risk. But helium was provided from other countries and have more price. The injuries which caused from acetylene burns like 1st -2nd degree burns. Consequently that was known helium is more avaliable for using in toy sector, and never cause burn injuries like this. [TAF Prev Med Bull. 2007; 6(4: 291-296

  2. Balloon catheter dilatation of benign urethral strictures

    International Nuclear Information System (INIS)

    The authors report their experience of benign urethral stricture dilatation by balloon catheter in 11 male patients. Ten posterior and 2 anterior urethral strictures were treated; in 1 patients several narrowings coexisted at various levels. Etiology was inflammatory in 4 cases, iatrogen in 3, post-traumatic in 2, and equivocal in 2. The patients were studied both before and soon after dilatation by means of retrograde and voiding cystourethrogram and uroflowgraphy; the follow-up (2-14 months) was performed by urodynamic alone. In all cases, dilatation was followed by the restoration of urethral gauge, together with prompt functional improvement of urodynamic parameters. The latter result subsisted in time in 9 patients. In 2 cases recurrences were observed demonstrated at once by clinics and urodynamics. Both lesions were successfully re-treated. Neither early not late complication occurred. In spite of the limited material, the valuable results obtained, together with the absence of complications, the peculiar morphology of recurrences, and the chance of repeating it make the procedure advisable as a valid alternative to conventional techniques for these pathologies

  3. Ballooning mode spectrum in general toroidal systems

    Energy Technology Data Exchange (ETDEWEB)

    Dewar, R.L.; Glasser, A.H.

    1982-04-01

    A WKB formalism for constructing normal modes of short-wavelength ideal hydromagnetic, pressure-driven instabilities (ballooning modes) in general toroidal magnetic containment devices with sheared magnetic fields is developed. No incompressibility approximation is made. A dispersion relation is obtained from the eigenvalues of a fourth order system of ordinary differential equations to be solved by integrating along a line of force. Higher order calculations are performed to find the amplitude equation and the phase change at a caustic. These conform to typical WKB results. In axisymmetric systems, the ray equations are integrable, and semiclassical quantization leads to a growth rate spectrum consisting of an infinity of discrete eigenvalues, bounded above by an accumulation point. However, each eigenvalue is infinitely degenerate. In the nonaxisymmetric case, the rays are unbounded in a four dimensional phase space, and semiclassical quantization breaks down, leading to broadening of the discrete eigenvalues and accumulation point of the axisymmetric case into continuum bands. Analysis of a model problem indicates that the broadening of the discrete eigenvalues is numerically very small, the dominant effect being broadening of the accumulation point.

  4. Alpha particle effects on MHD ballooning

    International Nuclear Information System (INIS)

    During the period, as the first step towards the goal of detail understanding of the effects of alpha particle on MHD Ballooning Modes, a new numerical approach to investigate the stability of low-frequency fluctuations in high temperature tokamaks was developed by solving the gyrokinetic equations for the ion and electron directly as an initial value problem. The advantage of this approach is the inclusion of many important kinetic features of the problem without approximations and computationally more economical than particle-pushing simulation. The ion-temperature-gradient-mode was investigated to benchmark this new simulation technique. Previous results in literature were recovered. Both the adiabatic electron model and the full drift-kinetic electron model are studied. Numerical result shows that the full drift-kinetic electron model is more unstable. The development of subcycling technique to handle the fast electron bounce time is particularly significant to apply this new approach to the alpha particle problem since alpha particle bounce frequency is also significantly higher than the mode frequency. This new numerical technique will be the basis of future study of the microstability in high temperature tokamaks with alpha particles (or any energetic species). 15 refs., 13 figs

  5. Angioplasty treatment and stent implant vs. surgical treatment in patients with stenosis of the cervical carotid artery

    International Nuclear Information System (INIS)

    Angioplasty with stent implant is a less invasive procedure than surgical intervention in the treatment of significant stenosis of the common cervical carotid artery (common and internal) (5). Currently the major published studies, in which angioplasty and surgical treatment are compared, show similar results in the major events, as cerebrovascular accidents and mortality, but a greater significant difference in the apparition of acute myocardial infarction, during surgical intervention (5,11). The objective of this study is to compare in both treatment methods the major and minor clinical events, like cerebrovascular accident, acute myocardial infarction, death, bradycardia, hypotension and encephalopathy during the intervention, the hospitalization and the follow-up year, as well as the re-intervention, the time of hospital stay and the complications of the surgical incision. Materials and methods: in this study of historical cohort, 46 patients with significant stenosis of the cervical carotid arteries, who were subjected to intervention from January 1st 2001 to December 31st 2003, were included. 21 patients were treated with angioplasty and stent implant and 25 with surgery (endarterectomy) Results: 1 (4.8%) major cerebrovascular accident occurred during angioplasty, whereas none occurred in the patients treated with surgery. 1 (4%) acute myocardial infarction occurred during intervention in the group of patients treated with surgery, and none in the patients treated with angioplasty. No deaths occurred in any of the groups during intervention, hospitalization and the follow-up year. After 8 months 1 (4%) patient treated with surgery was intervened again with angioplasty and stent implant. There were no statistically significant differences between both groups during hospitalization, and in the apparition of minor complications as bradycardia and hypotension. 2 (8%) complications related to the incision of the neck compromising cranial nerves, occurred in the

  6. Contribution of inhibitory receptor glycoprotein iib / iiia in coronary angioplasty and acute coronary syndrome, about 152 patients

    International Nuclear Information System (INIS)

    The aim of our study was to evaluate the immediate results and long-term intake of anti-GP IIb / IIIa inhibitors for patients with acute coronary syndrome treated with coronary angioplasty. The use of anti-GP IIb / IIIa is a valid therapeutic option in patients with acute coronary syndrome with signs of severity and for patients undergoing complex angioplasty. Adverse effects of anti-GP IIb / IIIa can be seen to encourage vigilance and careful monitoring during the administration of these molecules and perfect knowledge of their pharmacological properties for appropriate use.

  7. [Correction of dyslipidemia in patients with arteriosclerosis obliterans as a method for improving the results of endovascular angioplasty].

    Science.gov (United States)

    Petukhov, V A; Seitmykhamedov, M D; Dibirov, A D; Dubovik, S G; Sergeeva, N A; Prokubovskiĭ, V I

    1992-01-01

    The authors analyse the results of endovascular angioplasty of the pelvic and lower limb arteries in 147 patients of various age suffering from arteriosclerosis obliterans. It was found that the results of endovascular angioplasty depended on the state of the lipid balance. The necessity for correcting the shifts in the lipid metabolism is shown. The article evaluates the results of dyslipidemia correction by dietotherapy, pharmacotherapy, and operation for partial ilio-shunting in patients with arteriosclerosis obliterans of the pelvic and lower limb arteries. The efficacy of the listed methods of treatment are analysed according to the severity of dyslipidemia. PMID:1457133

  8. Impotence due to external Iliac steal syndrome: Treatment with percutaneous transluminal angioplasty and stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Gur, Serkan [Sifa University, Dept. of Radiology, Izmir (Turkmenistan); Oguzkurt, Levent; Kaya, Bilal; Tekbas, Guven; Ozkan, Ugur [Baskent University, Faculty of Medicine, Dept. of Radiology, Adana (Turkmenistan)

    2013-01-15

    We report a case of erectile dysfunction caused by external iliac artery occlusion, associated with pelvic steal syndrome; bilateral internal iliac arteries were patent. The patient stated that he had experienced erectile dysfunction at similar times along with claudication, but he did not mention it before angiography. He expressed that the erectile dysfunction did not last long and that he felt completely okay after the interventional procedure, in addition to his claudication. Successful treatment of the occlusion, by percutaneous transluminal angioplasty and stent implantation, helped resolve erectile dysfunction completely and treat the steal syndrome.

  9. Impotence due to external Iliac steal syndrome: Treatment with percutaneous transluminal angioplasty and stent placement

    International Nuclear Information System (INIS)

    We report a case of erectile dysfunction caused by external iliac artery occlusion, associated with pelvic steal syndrome; bilateral internal iliac arteries were patent. The patient stated that he had experienced erectile dysfunction at similar times along with claudication, but he did not mention it before angiography. He expressed that the erectile dysfunction did not last long and that he felt completely okay after the interventional procedure, in addition to his claudication. Successful treatment of the occlusion, by percutaneous transluminal angioplasty and stent implantation, helped resolve erectile dysfunction completely and treat the steal syndrome.

  10. Study of Traditional Chinese Medicine in Intervening Vascular Remodeling after Percutaneous Transluminal Coronary Angioplasty

    Institute of Scientific and Technical Information of China (English)

    鹿小燕; 徐浩; 史大卓; 陈可冀

    2004-01-01

    Interventional therapy of coronary heart disease (CHD) includes percutaneous transluminal coronary angioplasty (PTCA), stent implantation etc. Owing to its revascularization without cardiac surgery, it has been the main effective method in treating CHD. But at the same time, there exists the problem of restenosis (RS). After PTCA, RS rate can reach 30% to 50%, even with direct stenting into the vessels, it still reaches 20% to 35%. So this affects long-term effect of interventional therapy, which directly relates to prognosis of patients with CHD and has been a hot spot of study in the field of preventing and treating CHD.

  11. Study of Traditional Chinese Medicine in Intervening Vascular Remodeling after Percutaneous Transluminal Coronary Angioplasty

    Institute of Scientific and Technical Information of China (English)

    鹿小燕; 徐浩; 史大卓; 陈可冀

    2004-01-01

    Interventional therapy of coronary heart disease (CHD) includes percutaneous transluminal coronary angioplasty (PTCA), stent implantation etc. Owing to its revascularization without cardiac surgery, it has been the main effective method in treating CHD. But at the same time, there exists the problem of restenosis (RS). After PTCA, RS rate can reach 30% to 50%, even with directstenting into the vessels, it still reaches 20% to 35%. So this affects long-term effect of interventional therapy, which directly relates to prognosis of patients with CHD and has been a hot spot of study in the field of preventing and treating CHD.

  12. Two cases of radiation-induced skin injury following percutaneous transluminal coronary angioplasty (PTCA)

    International Nuclear Information System (INIS)

    Two cases of radiation-induced skin injury following percutaneous transluminal coronary angioplasty (PTCA) are reported. Case 1 is a 52-year-old man who underwent PTCA for 7 times. Case 2 is a 67-year-old man who underwent PTCA for 5 times. In both cases, a cutaneous lesion developed into an ulcer over the right infrascapular region. The ulcer was treated surgically. The histopathological features were compatible with chronic radiation dermatitis. To avoid such injury in interventional procedures with long fluoroscopic time, it is very important for medical staffs to recognize the radiation-induced skin injury and to reduce the patient's absorbed dose as much as possible. (author)

  13. Vascular responses to endovascular irradiation of 188Re in the rabbit model after angioplasty

    International Nuclear Information System (INIS)

    The effects on vascular restenosis of intravascular radiation delivery from 188Rhenium (Re)-perrhenate liquid-filled balloon through beta-particle radiation are controversial. To determine the effect of beta-radiation on vascular injury in hypercholesterolemic rabbits, thirty rabbits fed with a high cholesterol diet were enrolled into this study. All the rabbits underwent percutaneous transluminal balloon overstretch over left iliac artery. After balloon overstretch, the catheter was withdrawn and immediately followed by irradiation using low dose 188Re solution (10 Gray) in the vascular wall 0.5 mm distal to intimal surface. After 2 and 6 weeks, arteries were harvested for histological and immunological analysis. This rabbit study suggest that endovascular 188Re low dose irradiation at the non-injury segment of iliac artery may enhance intima hyperplasia and smooth muscle cell proliferation. (author)

  14. Drive Mechanisms for Peeling-Ballooning Modes and Implications for Kinetic Ballooning Modes

    Science.gov (United States)

    Lunniss, Amelia; Wilson, Howard; Snyder, Phil

    2015-11-01

    The EPED model of the H-mode pedestal in tokamak plasmas combines a kinetic ballooning mode (KBM) criterion for the critical pressure gradient with a non-local peeling-ballooning (P-B) mode stability criterion to provide an integrated picture of pedestal structure and ELMs. Employing a set of model tokamak equilibria with pedestal gradients constrained by the KBM criterion, we explore the P-B stability for different pedestal widths. The narrowest widths, corresponding to early in the ELM cycle, are stable. Once a critical width is realised, an intermediate-n P-B mode is destabilised, which we show to be driven by a combination of the kink and curvature contributions to δW, exceeding field line bending. Although formally of O(n-1) , we show that the kink term survives to very large n because of steep current density gradients in the pedestal. This kink term is not presently retained in gyro-kinetic codes, but may be important for an accurate prediction of the KBM stability criterion in realistic low collisionality tokamak pedestals. This project has received part funding from the European Union's Horizon 2020 research and innovation programme under grant agreement number 633053. The views and opinions expressed herein do not necessarily reflect those of the European Commission.

  15. Development of a super-pressure balloon with a diamond-shaped net --- result of a ground inflation test of a 2,000 cubic-meter balloon ---

    Science.gov (United States)

    Saito, Yoshitaka; Nakashino, Kyoichi; Akita, Daisuke; Matsushima, Kiyoho; Shimadu, Shigeyuki; Goto, Ken; Hashimoto, Hiroyuki; Matsuo, Takuma

    2016-07-01

    A light super-pressure balloon has been developed using a method to cover a balloon with a diamond-shaped net of high-tensile fibers. The goal is to fly a payload of 900 kg to the altitude of 37 km with a 300,000 m^{3} balloon. Beginning from a demonstration test of the net-balloon with a 10 m^{3} balloon in 2010, we have been polished the net-balloon through ground inflation tests and flight tests, including a flight test of a 3,000 m ^{3} balloon in the tandem balloon configuration with a 15,000 m^{3} zero-pressure balloon in 2012, and a flight test of a 10 m^{3} balloon in the tandem balloon configuration with a 2 kg rubber balloon in 2013, as reported in the last COSPAR. In 2014, we developed a 5,000 m^{3} balloon and performed a ground inflation test to find that the balloon burst from a lip panel for termination with a differential pressure of 425 Pa. It was due to a stress concentration at the edge of a thick tape attached along the termination mechanism. In 2015, we modified the balloon by adding tapes on the lip panel to avoid the stress concentration, and also shorten the net length to leave some margin of the film and performed a ground inflation test again to find the balloon showed asymmetrical deployment and burst from the edge of the net with a differential pressure of 348 Pa. We consider it is due to the margin of the film along the circumferential direction, and proposed a gore shape which circumference length is kept as determined by the pumpkin shape of the balloon but setting meridian length longer than that. We developed a 10 m^{3} balloon with the gore design to find that the balloon deployed symmetrically and showed the burst pressure of 10,000 Pa. In 2016, we are going to develop a 2,000 m^{3} balloon with the gore design and perform its ground inflation test. In this paper, we are going to report its result with the sequence of the development.

  16. Treatment of hemodialysis vascular access rupture irresponsive to prolonged balloon tamponade: Retrospective evaluation of the effectiveness of N-butyl cyanoacrylate seal-off technique

    Energy Technology Data Exchange (ETDEWEB)

    Weng, Mei Jul; Liang, Huei Lung; Pan, Huay Ben [Dept. of Radiology, Kaohsiung Veterans General Hospital, Kaohsiung (China); Chen, Matt Chiung Yu [Dept. of Radiology, Yuan' s General Hospital, Kaohsiung (China)

    2013-01-15

    The current study retrospectively evaluated whether the percutaneous N-butyl cyanoacrylate (NBCA) seal-off technique is an effective treatment for controlling the angioplasty-related ruptures, which are irresponsive to prolonged balloon tamponade, during interventions for failed or failing hemodialysis vascular accesses. We reviewed 1588 interventions performed during a 2-year period for dysfunction and/or failed hemodialysis vascular access sites in 1569 patients. For the angioplasty-related ruptures, which could not be controlled with repeated prolonged balloon tamponade, the rupture sites were sealed off with an injection of a glue mixture (NBCA and lipiodol), via a needle/needle sheath to the rupture site, under a sonographic guidance. Technical success rate, complications and clinical success rate were reported. The post-seal-off primary and secondary functional patency rates were calculated by a survival analysis with the Kaplan-Meier method. Twenty ruptures irresponsive to prolonged balloon tamponade occurred in 1588 interventions (1.3%). Two technical failures were noted; one was salvaged with a bailout stent-graft insertion and the other was lost after access embolization. Eighteen accesses (90.0%) were salvaged with the seal-off technique; of them, 16 ruptures were completely sealed off, and two lesions were controlled as acute pseudoaneurysms. Acute pseudoaneurysms were corrected with stentgraft insertion in one patient, and access ligation in the other. The most significant complication during the follow-up was delayed pseudoaneurysm, which occurred in 43.8% (7 of 16) of the completely sealed off accesses. Delayed pseudoaneurysms were treated with surgical revision (n = 2), access ligation (n = 2) and observation (n = 3). During the follow-up, despite the presence of pseudoaneurysms (acute = 1, delayed = 7), a high clinical success rate of 94.4% (17 of 18) was achieved, and they were utilized for hemodialysis at the mean of 411.0 days. The post

  17. Treatment of hemodialysis vascular access rupture irresponsive to prolonged balloon tamponade: Retrospective evaluation of the effectiveness of N-butyl cyanoacrylate seal-off technique

    International Nuclear Information System (INIS)

    The current study retrospectively evaluated whether the percutaneous N-butyl cyanoacrylate (NBCA) seal-off technique is an effective treatment for controlling the angioplasty-related ruptures, which are irresponsive to prolonged balloon tamponade, during interventions for failed or failing hemodialysis vascular accesses. We reviewed 1588 interventions performed during a 2-year period for dysfunction and/or failed hemodialysis vascular access sites in 1569 patients. For the angioplasty-related ruptures, which could not be controlled with repeated prolonged balloon tamponade, the rupture sites were sealed off with an injection of a glue mixture (NBCA and lipiodol), via a needle/needle sheath to the rupture site, under a sonographic guidance. Technical success rate, complications and clinical success rate were reported. The post-seal-off primary and secondary functional patency rates were calculated by a survival analysis with the Kaplan-Meier method. Twenty ruptures irresponsive to prolonged balloon tamponade occurred in 1588 interventions (1.3%). Two technical failures were noted; one was salvaged with a bailout stent-graft insertion and the other was lost after access embolization. Eighteen accesses (90.0%) were salvaged with the seal-off technique; of them, 16 ruptures were completely sealed off, and two lesions were controlled as acute pseudoaneurysms. Acute pseudoaneurysms were corrected with stentgraft insertion in one patient, and access ligation in the other. The most significant complication during the follow-up was delayed pseudoaneurysm, which occurred in 43.8% (7 of 16) of the completely sealed off accesses. Delayed pseudoaneurysms were treated with surgical revision (n = 2), access ligation (n = 2) and observation (n = 3). During the follow-up, despite the presence of pseudoaneurysms (acute = 1, delayed = 7), a high clinical success rate of 94.4% (17 of 18) was achieved, and they were utilized for hemodialysis at the mean of 411.0 days. The post

  18. British Society of Interventional Radiology Iliac Artery Angioplasty-Stent Registry III.

    Science.gov (United States)

    Uberoi, Raman; Milburn, Simon; Moss, Jon; Gaines, Peter

    2009-09-01

    The objective of this study was to audit current practice in iliac artery intervention in the United Kingdom. In 2001 the British Society of Interventional Radiology Iliac Artery Angioplasty-Stent (BIAS) III registry provided the first national database for iliac intervention. It recommended that data collection needed to continue in order to facilitate the dissemination of comparative data to individual units. BIAS III was designed to continue this work and has a simplified data set with an online submission form. Interventionalists were invited to complete a 3-page tick sheet for all iliac angioplasties and stents. Questions covered risk factors, procedural data, and outcome. Data for 2233 patients were submitted from 37 institutions over a 43-month period. Consultants performed 80% of the procedures, 62% of which were for claudication. Fifty-four percent of lesions were treated with stents and 25% of patients underwent bilateral intervention, resulting in a residual stenosis of <50% in 98%. Ninety-seven percent of procedures had no limb complication and there was a 98% inpatient survival rate. In conclusion, these figures provide an essential benchmark for both audit and patient information. National databases need to be expanded across the range of interventional procedures, and their collection made simple and, preferably, online. PMID:19644643

  19. British Society of Interventional Radiology Iliac Artery Angioplasty-Stent Registry III

    International Nuclear Information System (INIS)

    The objective of this study was to audit current practice in iliac artery intervention in the United Kingdom. In 2001 the British Society of Interventional Radiology Iliac Artery Angioplasty-Stent (BIAS) III registry provided the first national database for iliac intervention. It recommended that data collection needed to continue in order to facilitate the dissemination of comparative data to individual units. BIAS III was designed to continue this work and has a simplified data set with an online submission form. Interventionalists were invited to complete a 3-page tick sheet for all iliac angioplasties and stents. Questions covered risk factors, procedural data, and outcome. Data for 2233 patients were submitted from 37 institutions over a 43-month period. Consultants performed 80% of the procedures, 62% of which were for claudication. Fifty-four percent of lesions were treated with stents and 25% of patients underwent bilateral intervention, resulting in a residual stenosis of <50% in 98%. Ninety-seven percent of procedures had no limb complication and there was a 98% inpatient survival rate. In conclusion, these figures provide an essential benchmark for both audit and patient information. National databases need to be expanded across the range of interventional procedures, and their collection made simple and, preferably, online.

  20. Radiation dose and risk from fluoroscopically guided percutaneous transluminal angioplasty and stenting in the abdominal region

    International Nuclear Information System (INIS)

    The objective of this study was to estimate the radiation dose and associated risks resulting from fluoroscopically guided percutaneous transluminal angioplasty with or without stent placement in the abdominal region. Average examination parameters for renal and aortoiliac procedures were derived using data from 80 consecutive procedures performed in our institute. Organ and effective doses were estimated for endovascular procedures with the use of a Monte Carlo (MC) transport code and an adult mathematical phantom. Thermoluminescent dosimeters were used in an anthropomorphic phantom to verify MC calculations. Radiation-induced risks were estimated. Results are presented as doses normalized to dose area product, so that the patient dose from any technique and X-ray unit can be easily calculated for iliac and renal PTA/stenting sessions. The average effective dose varied from 75 to 371 μSv per Gycm2 depending on the beam quality, procedure scheme and sex of the patient. Differences up to 17% were observed between MC-calculated data and data derived from thermoluminescent dosimetry. The radiation-induced cancer risk may be considerable for younger individuals undergoing transluminal angioplasty with stent placement. (orig.)

  1. Five-year follow-up of angiographic disease progression after medicine, angioplasty, or surgery

    Directory of Open Access Journals (Sweden)

    Oliveira Sergio A

    2010-10-01

    Full Text Available Abstract Background Progression of atherosclerosis in coronary artery disease is observed through consecutive angiograms. Prognosis of this progression in patients randomized to different treatments has not been established. This study compared progression of coronary artery disease in native coronary arteries in patients undergoing surgery, angioplasty, or medical treatment. Methods Patients (611 with stable multivessel coronary artery disease and preserved ventricular function were randomly assigned to CABG, PCI, or medical treatment alone (MT. After 5-year follow-up, 392 patients (64% underwent new angiography. Progression was considered a new stenosis of ≥ 50% in an arterial segment previously considered normal or an increased grade of previous stenosis > 20% in nontreated vessels. Results Of the 392 patients, 136 underwent CABG, 146 PCI, and 110 MT. Baseline characteristics were similar among treatment groups, except for more smokers and statin users in the MT group, more hypertensives and lower LDL-cholesterol levels in the CABG group, and more angina in the PCI group at study entry. Analysis showed greater progression in at least one native vessel in PCI patients (84% compared with CABG (57% and MT (74% patients (p Conclusion The angioplasty treatment conferred greater progression in native coronary arteries, especially in the left anterior descending territories and treated vessels. The progression was independently associated with hypertension, male sex, and previous myocardial infarction.

  2. Intradural vertebral endarterectomy with nonautologous patch angioplasty for refractory vertebrobasilar ischemia: Case report and literature review

    Directory of Open Access Journals (Sweden)

    Timothy Uschold

    2014-01-01

    Full Text Available Background: The natural history of patients with symptomatic vertebrobasilar ischemic symptoms due to chronic bilateral vertebral artery occlusive disease is progressive, and poses significant challenges when refractory to medical therapy. Surgical treatment options depend largely on location and characteristics of the atheroma (s, and generally include percutaneous transluminal angioplasty (PTA with or without stent placement, posterior circulation revascularization (bypass, extracranial vertebral artery reconstruction, or vertebral artery endarterectomy. Case Description: We present the case of a 56-year-old male with progressive vertebrobasilar ischemia due to tandem lesions in the right vertebral artery at the origin and intracranially in the V4 segment. The contralateral vertebral artery was occluded to the level of posterior inferior cerebellar artery (PICA and posterior communicating arteries were absent. Following PTA and stent placement at the right vertebral artery origin, the patient was successfully treated with intradural vertebral artery endarterectomy (V4EA and patch angioplasty via the far lateral approach. Distal endovascular intervention at the V4 segment proved not technically feasible after multiple attempts. Conclusions: V4EA is an uncommonly performed procedure, but may be considered for carefully selected patients. The authors′ techniques and indications are discussed. Historical outcomes, relevant anatomic considerations, and lessons learned are reviewed from the literature.

  3. Endovascular gamma irradiation for the prevention restenosis after angioplasty of femoropopliteal de novo stenoses

    International Nuclear Information System (INIS)

    The purpose of this study was to investigate the effectiveness and detect side effects of centered, overlapped endovascular gamma irradiation after angioplasty of de novo femoropopliteal stenoses. Thirty patients (age 65.3±9.2 years) with arterial occlusive disease were prospectively enrolled to receive endovascular gamma irradiation (192-iridium, 14 Gy centered at 2 mm vessel wall) immediately after percutaneous transluminal angioplasty (PTA) of femoropopliteal stenoses. Irradiation overlapped dilatation by 1-2 cm at each end. Follow-up involved angiography after 12 months; duplex sonography; and interviews before and after PTA and at 1, 6, and 12 months follow-up. PTA and centered endovascular irradiation were performed successfully in all patients. Three thromboembolic complications occurred during irradiation. Angiographic and clinical follow-up was possible in 28 patients. The angiographic degree of stenosis was 73.8%±16.3% before and 3.6%±23.5% after PTA and was 3.5%±43.7% at the 1-year follow-up. Restenosis (>50%) of the target lesion developed in three patients (10.7%) and edge stenoses (>30%) in nine patients (32.1%). An aneurysm of the irradiated segment in one patient was treated by stenting. The rate of retreatment was 17.9%. The vessel diameter after endovascular gamma irradiation and PTA of femoropopliteal stenoses remained stable. Restenosis, induction of edge stenoses, and aneurysm were reasons for reinterventions. (orig.)

  4. Radiation dose and risk from fluoroscopically guided percutaneous transluminal angioplasty and stenting in the abdominal region

    Energy Technology Data Exchange (ETDEWEB)

    Stratakis, John; Damilakis, John [University of Crete, Department of Medical Physics, P.O. Box 2208, Iraklion, Crete (Greece); Tsetis, Dimitrios; Gourtsoyiannis, Nicholas [University of Crete, Department of Radiology, P.O. Box 2208, Iraklion, Crete (Greece)

    2007-09-15

    The objective of this study was to estimate the radiation dose and associated risks resulting from fluoroscopically guided percutaneous transluminal angioplasty with or without stent placement in the abdominal region. Average examination parameters for renal and aortoiliac procedures were derived using data from 80 consecutive procedures performed in our institute. Organ and effective doses were estimated for endovascular procedures with the use of a Monte Carlo (MC) transport code and an adult mathematical phantom. Thermoluminescent dosimeters were used in an anthropomorphic phantom to verify MC calculations. Radiation-induced risks were estimated. Results are presented as doses normalized to dose area product, so that the patient dose from any technique and X-ray unit can be easily calculated for iliac and renal PTA/stenting sessions. The average effective dose varied from 75 to 371 {mu}Sv per Gycm{sup 2} depending on the beam quality, procedure scheme and sex of the patient. Differences up to 17% were observed between MC-calculated data and data derived from thermoluminescent dosimetry. The radiation-induced cancer risk may be considerable for younger individuals undergoing transluminal angioplasty with stent placement. (orig.)

  5. Aerial Deployment and Inflation System for Mars Helium Balloons

    Science.gov (United States)

    Lachenmeler, Tim; Fairbrother, Debora; Shreves, Chris; Hall, Jeffery, L.; Kerzhanovich, Viktor V.; Pauken, Michael T.; Walsh, Gerald J.; White, Christopher V.

    2009-01-01

    A method is examined for safely deploying and inflating helium balloons for missions at Mars. The key for making it possible to deploy balloons that are light enough to be buoyant in the thin, Martian atmosphere is to mitigate the transient forces on the balloon that might tear it. A fully inflated Mars balloon has a diameter of 10 m, so it must be folded up for the trip to Mars, unfolded upon arrival, and then inflated with helium gas in the atmosphere. Safe entry into the Martian atmosphere requires the use of an aeroshell vehicle, which protects against severe heating and pressure loads associated with the hypersonic entry flight. Drag decelerates the aeroshell to supersonic speeds, then two parachutes deploy to slow the vehicle down to the needed safe speed of 25 to 35 m/s for balloon deployment. The parachute system descent dynamic pressure must be approximately 5 Pa or lower at an altitude of 4 km or more above the surface.

  6. Time-dependent strains and stresses in a pumpkin balloon

    Science.gov (United States)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    2006-01-01

    This paper presents a study of pumpkin-shaped superpressure balloons, consisting of gores made from a thin polymeric film attached to high stiffness, meridional tendons. This type of design is being used for the NASA ULDB balloons. The gore film shows considerable time-dependent stress relaxation, whereas the behaviour of the tendons is essentially time-independent. Upon inflation and pressurization, the "instantaneous", i.e. linear-elastic strain and stress distribution in the film show significantly higher values in the meridional direction. However, over time, and due to the biaxial visco-elastic stress relaxation of the the material, the hoop strains increase and the meridional stresses decrease, whereas the remaining strain and stress components remain substantially unchanged. These results are important for a correct assessment of the structural integrity of a pumpkin balloon in a long-duration mission, both in terms of the material performance and the overall stability of the shape of the balloon. An experimental investigation of the time dependence of the biaxial strain distribution in the film of a 4 m diameter, 48 gore pumpkin balloon is presented. The inflated shape of selected gores has been measured using photogrammetry and the time variation in strain components at some particular points of these gores has been measured under constant pressure and temperature. The results show good correlation with a numerical study, using the ABAQUS finite-element package, that includes a widely used model of the visco-elastic response of the gore material:

  7. Complexity Analysis of Balloon Drawing for Rooted Trees

    CERN Document Server

    Lin, Chun-Cheng; Poon, Sheung-Hung; Fan, Jia-Hao

    2010-01-01

    In a balloon drawing of a tree, all the children under the same parent are placed on the circumference of the circle centered at their parent, and the radius of the circle centered at each node along any path from the root reflects the number of descendants associated with the node. Among various styles of tree drawings reported in the literature, the balloon drawing enjoys a desirable feature of displaying tree structures in a rather balanced fashion. For each internal node in a balloon drawing, the ray from the node to each of its children divides the wedge accommodating the subtree rooted at the child into two sub-wedges. Depending on whether the two sub-wedge angles are required to be identical or not, a balloon drawing can further be divided into two types: even sub-wedge and uneven sub-wedge types. In the most general case, for any internal node in the tree there are two dimensions of freedom that affect the quality of a balloon drawing: (1) altering the order in which the children of the node appear in...

  8. Development of Ultra-Thin Polyethylene Balloons for High Altitude Research upto Mesosphere

    Science.gov (United States)

    Kumar, B. Suneel; Nagendra, N.; Ojha, D. K.; Peter, G. Stalin; Vasudevan, R.; Anand, D.; Kulkarni, P. M.; Reddy, V. Anmi; Rao, T. V.; Sreenivasan, S.

    Ever since its inception four decades back, Balloon Facility of Tata Institute of Fundamental Research (TIFR), Hyderabad has been functioning with the needs of its user scientists at its focus. During the early nineties, when the X-ray astronomy group at TIFR expressed the need for balloons capable of carrying the X-ray telescopes to altitudes up to 42 km, the balloon group initiated research and development work on indigenous balloon grade films in various thickness not only for the main experiment but also in parallel, took up the development of thin films in thickness range 5 to 6 μm for fabrication of sounding balloons required for probing the stratosphere up to 42 km as the regular 2000-gram rubber balloon ascents could not reach altitudes higher than 38 km. By the year 1999, total indigenization of sounding balloon manufacture was accomplished. The work on balloon grade ultra-thin polyethylene film in thickness range 2.8 to 3.8 μm for fabrication of balloons capable of penetrating mesosphere to meet the needs of user scientists working in the area of atmospheric dynamics commenced in 2011. Pursuant to the successful trials with 61,000-m3 balloon made of 3.8-μm Antrix film reaching stratopause (48 km) for the first time in the history of balloon facility in the year 2012, fine tuning of launch parameters like percentage free lift was carried out to take the same volume balloons to higher mesospheric altitudes. Three successful flights with a total suspended load of 10 kg using 61,000-m3 balloons were carried out in the month of January 2014 and all the three balloons crossed into the mesosphere reaching altitudes of over 51 km. All the balloons flown so far are closed system with no escape ducts. Balloon fabrication, development of launch hardware, flight control instruments and launch technique for these mesospheric balloon flights are discussed in this paper.

  9. Monte Carlo calculations of dose distribution for intramural delivery of radioisotopes using a direct injection balloon catheter

    International Nuclear Information System (INIS)

    Purpose: A unique method of delivering radiation dose to the coronary vessel wall to prevent restenosis is by direct injection of radioactive compounds into the vessel wall using a specially designed angioplasty balloon catheter. The radiation dose distribution resulting from such intramural delivery was investigated using Monte Carlo simulations. Materials and methods: The radioisotope source distribution was modeled for two configurations within the vessel wall: (1) uniform to a depth of 0.5 mm and (2) confined to discrete pools surrounding the delivery injection ports. Monte Carlo MCNP4B computer simulations were utilized to estimate the associated radiation dose distribution for the following radioisotopes: 188Re, 186Re, 32P, 153Sm, 111In, 123I, and 99mTc. Results: For the uniform case where the radioisotopes are distributed uniformly to the depth of 0.5 mm into the vessel wall, an essentially constant radiation dose is delivered within the source distribution. Outside of the source volume, the dose falls off at a rate depending on the emission properties of the particular radioisotope. The nonuniform case involving discrete pools of activity showed the dose distribution being confined largely to the regions surrounding the delivery ports with significant regions between these ports receiving very little dose. Conclusions: Direct injection of selected radioisotopes into the arterial wall appears to represent a potentially effective method for delivering radiation dose for the prevention of restenosis. Sufficiently high doses may be obtained from relatively low activity and the dose falls off rapidly outside of the target area for certain radioisotopes

  10. Treatment of symptomatic intracranial atheromatous stenosis with the Gateway balloon and Wingspan stent system: short and medium term results

    International Nuclear Information System (INIS)

    Objective: To assess the safety, feasibility and short-mid term effectiveness of the Wingspan stent in the treatment of high-grade symptomatic intracranial atheromatous stenosis. Methods: Sixty-three patients with symptomatic intracranial atheromatous stenosis (≥70%) were treated with the Gateway balloon-Wingspan stent system. The pre-and post-treatment improvement of symptoms, severity of stenosis, successful rate of treatment, complications were evaluated. Physician-reported follow-up in all 63 patients lasted an average period of 9.3 months. The χ2 test was used for statistics. Results: Sixty-three lesions involved the intracranial internal carotid artery (n=12), middle cerebral artery (n=22), V4 segment vertebral artery (n=15), basilar artery (n=14). Sixty-two lesions were successfully treated with the deployment of the self-expanding Wingspan stent with residual stenosis ≤30%. One case failed because of intracranial hemorrhage during the operation. The successful rate of stenting is 98.0% (62/63). The mean stenosis was (82.3 ± 9.2)% before treatment, and it improved to (23.0 ± 11.2)% after stent placement. During the follow-up period, 1 patient died of postprocedural hyper-perfusion, one had ischemic stroke after procedure, one presented Homer syndrome at the 11th day, one had ischemic stroke at the 5th month after the procedure, while the other patients had significantly improved. The frequency of ≥50% restenosis on follow-up angiography or computed tomography was 10% (1/10). Conclusions: Angioplasty and stenting for high-grade symptomatic intracranial artery stenosis with the Gateway-Wingspan stent system are safe and effective with high rate of technical success, but moderately high rate of residual stenosis and restenosis exist. With the improvement of operation skill and stent system, a better outcome in the future could be achieved. (authors)

  11. Cardiac troponin T and CK-MB mass release after visually successful percutaneous transluminal coronary angioplasty in stable angina pectoris

    DEFF Research Database (Denmark)

    Ravkilde, J; Nissen, H; Mickley, H;

    1994-01-01

    The incidence of cardiac troponin T (Tn-T) and creatine kinase (CK) isoenzyme MB mass release was studied in 23 patients with stable angina pectoris undergoing visually successful percutaneous transluminal coronary angioplasty (PTCA). Serial blood samples were drawn for measurement of serum Tn...

  12. High-n ballooning modes in highly elongated tokamaks

    International Nuclear Information System (INIS)

    An analytic study of stability against high-n ballooning modes is highly elongated axisymmetric plasmas is presented and compared with computational results. - From the equation for the marginal pressure gradient, it is found that local shear has an important effect on the stability of elongated plasmas, and that stability deteriorates through high elongation since the stabilizing effects of field line bending and local shear are reduced. The net contribution of the local shear to stability decreases with elongation for strong ballooning modes (eigenfunctions strongly localized near the outer edge of the toroidal flux surfaces) but increases for interchange modes (eigenfunctions more uniform along the flux surfaces). - The computational study of high-n ballooning modes in a highly elongated plasma reveals that lowering the aspect ratio and broadening the pressure profile enhance the marginal beta for βsub(p) less than unity but severely reduce the marginal beta for βsub(p) larger than unity. (author)

  13. Review of the British scientific sounding rocket and balloon programmes

    International Nuclear Information System (INIS)

    This review describes the UK scientific sounding rocket programmes which have utilised Skylarks for 21 years, Petrels for 10 years and Fulmars for 2 years. The SRC's ongoing programme is now based on the Petrel and Fulmar rockets, and approved proposals by 5 UK scientific groups covering 1978 and 1979 are outlined. The British scientific balloon programme, which serves 14 scientific groups within UK universities, involves a planned 10 flights per annum using balloons of 3 M cu ft to 31 M cu ft capacity and payloads up to 2 tons in weight. The review outlines the balloon programme of flights planned mainly from Palestine in Texas and Alice Springs/Mildura in Australia. (author)

  14. Iridium: Global OTH data communications for high altitude scientific ballooning

    Science.gov (United States)

    Denney, A.

    While the scientific community is no stranger to embracing commercially available technologies, the growth and availability of truly affordable cutting edge technologies is opening the door to an entirely new means of global communications. For many years high altitude ballooning has provided science an alternative to costly satellite based experimental platforms. As with any project, evolution becomes an integral part of development. Specifically in the NSBF ballooning program, where flight durations have evolved from the earlier days of hours to several weeks and plans are underway to provide missions up to 100 days. Addressing increased flight durations, the harsh operational environment, along with cumbersome and outdated systems used on existing systems, such as the balloon vehicles Support Instrumentation Package (SIP) and ground-based systems, a new Over-The-Horizon (OTH) communications medium is sought. Current OTH equipment planning to be phased-out include: HF commanding systems, ARGOS PTT telemetry downlinks and INMARSAT data terminals. Other aspects up for review in addition to the SIP to utilize this communications medium include pathfinder balloon platforms - thereby, adding commanding abilities and increased data rates, plus providing a package for ultra-small experiments to ride aloft. Existing communication systems employed by the National Scientific Balloon Facility ballooning program have been limited not only by increased cost, slow data rates and "special government use only" services such as TDRSS (Tracking and Data Relay Satellite System), but have had to make special provisions to geographical flight location. Development of the Support Instrumentation Packages whether LDB (Long Duration Balloon), ULDB (Ultra Long Duration Balloon) or conventional ballooning have been plagued by non-standard systems configurations requiring additional support equipment for different regions and missions along with a myriad of backup for redundancy. Several

  15. Dynamic electromechanical instability of a dielectric elastomer balloon

    Science.gov (United States)

    Chen, Feifei; Zhu, Jian; Wang, Michael Yu

    2015-11-01

    Electromechanical instability, a significant phenomenon in dielectric elastomers, has been well studied in the literature. However, most previous work was based on the assumption that dielectric elastomers undergo quasi-static deformation. This letter investigates the dynamic electromechanical instability of a dielectric elastomer balloon which renders four types of oscillation subject to a parametric combination of DC and AC voltages. The simulated oscillations show that dynamic electromechanical instability occurs within quite a large range of excitation frequency, in the form of snap-through or snap-back, when the DC and AC voltages reach critical values. The balloon is at its most susceptible to dynamic electromechanical instability when the superharmonic, harmonic or subharmonic resonance is excited. Taking all excitation parameters into account, this letter analyzes the global critical condition which triggers the dynamic electromechanical instability of the balloon.

  16. Popping balloons: formation of a crack network in rubber membranes

    Science.gov (United States)

    Moulinet, Sebastien; Adda-Bedia, Mokhtar; Equipe Morphogenèse et phénomènes multi-échelle Team

    2015-03-01

    Everyone can make the observation: a rubber balloon inflated until it spontaneously pop breaks into a large number of shreds. In contrast, a balloon pierced with a needle at an early stage of its inflation breaks into two large pieces. Using model latex balloons, we have experimentally investigated the transition between these two breaking regimes. We have showed that, above a threshold stress in the latex membrane, a single crack become unstable and separates into two new cracks. Then, a cascade of tip-splitting generates a network of cracks that eventually form a large number of fragments. We have observed that the instability of the crack occurs when it reaches a limit velocity that could the speed of sound. By studying the energy balance during the explosion, we can determine the intrinsic fracture energy of rubber, a measurement difficult to achieve with usual tensile testing.

  17. Extrusion process optimization for toughness in balloon films

    Science.gov (United States)

    Cantor, K. M.; Harrison, I. R.

    1993-01-01

    An experimental optimization process for blown film extrusion is described and examined in terms of the effects of the technique on the toughness of balloon films. The optimization technique by Cantor (1990) is employed which involves the identification of key process variables including screw speed, nip speed, bubble diameter, and frost-line height for analysis to optimize the merit function. The procedure is employed in the extrusion of a low-density polyethylene polymer, and the resulting optimized materials are toughness- and puncture-tested. Balloon toughness is optimized in the analytical relationship, and the process parameters are modified to attain optimal toughness. The film produced is shown to have an average toughness of 24.5 MPa which is a good value for this key property of balloon materials for high-altitude flights.

  18. Tokamak resistive magnetohydrodynamic ballooning instability in the negative shear regime

    Institute of Scientific and Technical Information of China (English)

    Shi Bing-Ren; Lin Jian-Long; Li Ji-Quan

    2007-01-01

    Improved confinement of tokamak plasma with central negative shear is checked against the resistive ballooning mode. In the negative shear regime, the plasma is always unstable for purely growing resistive ballooning mode. For a simplest tokamak equilibrium model, the s-α model, characteristics of this kind of instability are fully clarified by numerically solving the high n resistive magnetohydrodynamic ballooning eigen-equation. Dependences of the growth rate on the resistivity, the absolute shear value, the pressure gradient are scanned in detail. It is found that the growth rate is a monotonically increasing function of a while it is not sensitive to the changes of the shear s, the initial phase θ0 and the resistivity parameter εR.

  19. Balloon vetebroplasty with calcium phosphate cement augmentation for direct restoration of traumatic thoracolumbar vertebral fractures

    NARCIS (Netherlands)

    Verlaan, JJ; van Helden, WH; Oner, FC; Verbout, AJ; Dhert, WJA

    2002-01-01

    Study Design. A human cadaveric model was used to evaluate balloon vertebroplasty in traumatic vertebral fractures. Objectives. To assess the feasibility and safety of balloon vertebroplasty followed by calcium phosphate cement augmentation to prevent recurrent kyphosis. Summary of Background Data.

  20. Membranous duodenal stenosis: Initial experience with balloon dilatation in four children

    Energy Technology Data Exchange (ETDEWEB)

    Rijn, R.R. van [Department of Radiology, Academic Medical Centre Amsterdam (Netherlands); Lienden, K.P. van [Department of Radiology, Academic Medical Centre Amsterdam (Netherlands); Fortuna, T.L. [Dalhousie University, Medical school, Halifax (Canada); Department of Diagnostic Imaging, Hospital for Sick Children, Toronto (Canada); D' Alessandro, L.C.A. [University of Western Ontario, Schulich School of Medicine, London (Canada); Department of Diagnostic Imaging, Hospital for Sick Children, Toronto (Canada); Connolly, B. [Department of Diagnostic Imaging, Hospital for Sick Children, Toronto (Canada); Chait, P.G. [Department of Diagnostic Imaging, Hospital for Sick Children, Toronto (Canada)]. E-mail: peter.chait@rogers.com

    2006-07-15

    Introduction: We present a novel approach to the treatment of membranous duodenal stenosis (MDS). To our knowledge this is the first paper to describe balloon dilatation for this entity. Material and methods: Four children, 2 boys and 2 girls, aged between 8 and 28 days, underwent duodenal balloon dilatation. Balloon dilatation was performed under general anaesthesia using standard angiography balloons per os. Balloon diameters ranged from 6 to 14 mm. Results: All balloon dilatations were successful. None of the procedures showed procedural or post-procedural complications. None of the patients subsequently required surgical intervention. To date all children are doing well. Discussion: The initial experience with balloon dilation of MDS showed a 100% success rate, without procedural or post-procedural complications. The results obtained in this small group of patients suggest that the use of balloon dilatation in cases of MDS may be a safe technique that can be readily performed by an experienced interventional radiologist.

  1. Membranous duodenal stenosis: Initial experience with balloon dilatation in four children

    International Nuclear Information System (INIS)

    Introduction: We present a novel approach to the treatment of membranous duodenal stenosis (MDS). To our knowledge this is the first paper to describe balloon dilatation for this entity. Material and methods: Four children, 2 boys and 2 girls, aged between 8 and 28 days, underwent duodenal balloon dilatation. Balloon dilatation was performed under general anaesthesia using standard angiography balloons per os. Balloon diameters ranged from 6 to 14 mm. Results: All balloon dilatations were successful. None of the procedures showed procedural or post-procedural complications. None of the patients subsequently required surgical intervention. To date all children are doing well. Discussion: The initial experience with balloon dilation of MDS showed a 100% success rate, without procedural or post-procedural complications. The results obtained in this small group of patients suggest that the use of balloon dilatation in cases of MDS may be a safe technique that can be readily performed by an experienced interventional radiologist

  2. To sail the skies of Mars - Scientific ballooning on the red planet

    Science.gov (United States)

    Gaidos, Eric J.; Burke, James D.

    1988-01-01

    Balloons represent a novel approach to exploring the surface of Mars. One promising aerostat system incorporates a solar-powered balloon as a means of generating diurnally varying lift and so can 'hop' across the surface, obtaining detailed information at a large number of sites. Two important areas of research and testing are underway on solar balloon technology and balloon payload design. The solar balloon concept has been demonstrated on earth, but more work is needed on a 'flyable' version for Mars. Particular attention must be paid to radiation heat transfer and aerodynamic effects. A special 'snake' payload concept has been demonstrated that allows for balloon system traverses of the surface and provides a usable instrument platform. A balloon system of this type could obtain unique surface imaging and physical and chemical data. The flight of the balloon also provides in situ atmospheric boundary-layer and circulation measurements.

  3. Captopril for prevention of Contrast Induced Nephropathy in patients undergoing Coronary Angioplasty: A double blind placebo controlled clinical trial

    Directory of Open Access Journals (Sweden)

    M Hashemi

    2005-09-01

    Full Text Available Background: Contrast induced nephropathy is a potential cause of mortality and morbidity in patients undergoing angiography–angioplasty. Except for hydrating and probably low – isoosmolar contrast agents in high risk groups, other modalities have not provided benefit. We investigated preventive effects of captopril for contrast induced nephropathy during angiography–angioplasty. Methods: In a double blind placebo controlled clinical trial, 88 patients were randomized to two groups: 42 patients received captopril (12.5 mg every 8 hours from 2 hours before the procedure until 48 hours thereafter, and 46 patients received placebo in the same manner. Serum creatinine was measured before and 48 hours after angioplasty. The data were analyzed by SPSS software, using unpaired student t-test for comparing mean creatinine rise in both groups and paired student t-test for the changes in serum creatinine in each group. Results: The mean creatinine rise in captopril group (0.214 mg/dl and placebo group (0.226 mg/dl were not significantly different. The incidence of acute renal failure (creatinine rise more than 0.5 mg/dl in the captopril (11.9 % and placebo group (10.8 % were not significantly different. Conclusion: Captopril does not effectively prevent contrast nephropathy, but it is not harmful for renal function and can be administered safely during angiography – angioplasty in patients with normal renal function. However, the effect of captopril in patients with high- risk characteristics remains to be clarified. Of note, we found a trend for less creatinine rise in diabetics who received captopril during the procedure in comparison to diabetics who received placebo. Keywords: Angiography, Angioplasty, Contrast induced Nephropathy, Captopril, Angiotension Converting Enzyme Inhibitor, Creatinine

  4. Intimal Hyperplasia in Balloon Dilated Coronary Arteries is Reduced by Local Delivery of the NO Donor, SIN-1 Via a cGMP-Dependent Pathway

    Directory of Open Access Journals (Sweden)

    Arner Anders

    2011-06-01

    Full Text Available Abstract Background To elucidate the mechanism by which local delivery of 3-morpholino-sydnonimine (SIN-1 affects intimal hyperplasia after percutaneous transluminal coronary angioplasty (PTCA. Methods Porcine coronary arteries were treated with PTCA and immediately afterwards locally treated for 5 minutes, with a selective cytosolic guanylate cyclase inhibitor, 1 H-(1,2,4oxadiazole(4,3-alphaquinoxaline-1-one (ODQ + SIN-1 or only SIN-1 using a drug delivery-balloon. Arteries were angiographically depicted, morphologically evaluated and analyzed after one and eight weeks for actin, myosin and intermediate filaments (IF and nitric oxide synthase (NOS contents. Results Luminal diameter after PCI in arteries treated with SIN-1 alone and corrected for age-growth was significantly larger as compared to ODQ + SIN-1 or to controls (p Conclusions After PTCA local delivery of high concentrations of the NO donor SIN-1 for 5 minutes inhibited injury induced neointimal hyperplasia. This favorable effect was abolished by inhibition of guanylyl cyclase indicating mediation of a cyclic guanosine 3',5'-monophosphate (cGMP-dependent pathway. The momentary events at the time of injury play crucial role in the ensuring development of intimal hyperplasia.

  5. The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII)

    Science.gov (United States)

    Rinehart, Stephen A.

    2010-01-01

    Astronomical studies at infrared wavelengths have dramatically improved our understanding of the universe. The relatively low angular resolution of these missions, however, is insufficient to resolve the physical scale on which mid-to far-infrared emission arises. We will build the Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII), an eight-meter Michelson interferometer to fly on a high-altitude balloon. BETTII's spectral-spatial capability, provided by an instrument using double-Fourier techniques, will address key questions about the nature of disks in young star clusters and active galactic nuclei and the envelopes of evolved stars. BETTII will also lay the technological groundwork for future space interferometers.

  6. Balloon-borne video cassette recorders for digital data storage

    International Nuclear Information System (INIS)

    A high-speed, high-capacity digital data storage system has been developed for a new balloon-borne gamma-ray telescope. The system incorporates sophisticated, yet easy to use and economical consumer products: the portable video cassette recorder (VCR) and a relatively newer item - the digital audio processor. The in-flight recording system employs eight VCRs and will provide a continuous data storage rate of 1.4 megabits/sec throughout a 40 hour balloon flight. Data storage capacity is 25 gigabytes and power consumption is only 10 watts

  7. Testing in a stratospheric balloon of a semiconductor detector altimeter

    International Nuclear Information System (INIS)

    An altimeter containing a semiconductor detector has been operated on flight. We have used a stratospheric balloon launched from AIRE-SUR-ADOUR with the C.N.E.S. collaboration. During this assay two apparatus have been used. The first allowed to follow the balloon during its ascension and descent, the second to follow its evolution at its maximum altitude. Informations transmitted by radio and recorded on Magnetophon, have been studied after the flight. Results are identical with these given by the barometer used by the C.N.E.S. in this essay. (authors)

  8. Nonlinear simulation of resistive ballooning modes in Large Helical Device

    International Nuclear Information System (INIS)

    Nonlinear simulations of a magneto-hydrodynamic (MHD) plasma in full three-dimensional geometry of the Large Helical Device (LHD) are conducted to study nonlinear evolution of pressure-driven instabilities. A series of simulations for a resistive plasma shows growth of resistive ballooning instability. The growth rate of the most unstable resistive ballooning mode is shown to be proportional to the one-third power of the resistivity. Nonlinear saturation of the instability and its slow decay are observed. After the nonlinear saturation, the pressure takes a profile similar to so-called pedestal. A possible scenario of nonlinear relaxation of a plasma toward a new equilibrated state is discussed. (author)

  9. Polymer blends for LDB applications. [Long Duration Ballooning

    Science.gov (United States)

    Lichkus, Andrew M.; Harrison, Ian R.

    1991-01-01

    A series of LCP/PE blends have been studied to determine the potential of such systems to produce a high modulus balloon film material which retains the balloon fabrication and low temperature flight advantages of the current PE films. Blown films of blends of 5 and 15 percent LCP in PE have been produced which show a 28 percent enhancement in modulus over the neat PE matrix. These results are substantially lower than anticipated and are explained in terms of the LCP reinforcement aspect ratio and fibril diameter.

  10. BETTII: The Balloon Experimental Twin Telescope for Infrared Interferometry

    Science.gov (United States)

    Rinehart, Stephen

    2011-01-01

    Astronomical studies at infrared wavelengths have dramatically improved our understanding the universe. The relatively low angular resolution of these missions, however, is insufficient to resolve the physical scale on which mid-to far-infrared emission arises. We will build the Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII),8oeight-meter Michelson interferometer to fly on a high-altitude balloon. BETTII's spectral-spatial capability, provided by an instrument using double-Fourier techniques, will address key questions about the nature of disks io young star clusters and active galactic nuclei and the envelopes of evolved stars. BETTII will also lay the technological groundwork for future space interferometers.

  11. The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII)

    Science.gov (United States)

    Rinehart, Stephen

    2012-01-01

    The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-meter baseline far-infrared interferometer to fly on a high altitude balloon. BETTII uses a double-Fourier Michelson interferometer to simultaneously obtain spatial and spectral information on science targets; the long baseline provides subarcsecond angular resolution, a capability unmatched by other far-infrared facilities. Here, we present key aspects of the overall design of the mission and provide an overview of the current status of the project. We also discuss briefly the implications of this experiment for future space-based far-infrared interferometers.

  12. AIAA Educator Academy: The Space Weather Balloon Module

    Science.gov (United States)

    Longmier, B.; Henriquez, E.; Bering, E. A.; Slagle, E.

    2013-12-01

    Educator Academy is a K-12 STEM curriculum developed by the STEM K-12 Outreach Committee of the American Institute of Aeronautics and Astronautics (AIAA). Consisting of three independent curriculum modules, K-12 students participate in inquiry-based science and engineering challenges to improve critical thinking skills and enhance problem solving skills. The Space Weather Balloon Curriculum Module is designed for students in grades 9-12. Throughout this module, students learn and refine physics concepts as well as experimental research skills. Students participate in project-based learning that is experimental in nature. Students are engaged with the world around them as they collaborate to launch a high altitude balloon equipped with HD cameras.The program leaders launch high altitude weather balloons in collaboration with schools and students to teach physics concepts, experimental research skills, and to make space exploration accessible to students. A weather balloon lifts a specially designed payload package that is composed of HD cameras, GPS tracking devices, and other science equipment. The payload is constructed and attached to the balloon by the students with low-cost materials. The balloon and payload are launched with FAA clearance from a site chosen based on wind patterns and predicted landing locations. The balloon ascends over 2 hours to a maximum altitude of 100,000 feet where it bursts and allows the payload to slowly descend using a built-in parachute. The payload is located using the GPS device. In April 2012, the Space Weather Balloon team conducted a prototype field campaign near Fairbanks Alaska, sending several student-built experiments to an altitude of 30km, underneath several strong auroral displays. To better assist teachers in implementing one or more of these Curriculum Modules, teacher workshops are held to give teachers a hands-on look at how this curriculum is used in the classroom. And, to provide further support, teachers are each

  13. Cosmic ray abundance measurements with the CAKE balloon experiment

    CERN Document Server

    Cecchini, S; Giacomelli, G; Manzoor, S; Medinaceli, E; Patrizii, L; Togo, V

    2005-01-01

    We present the results from the CAKE (Cosmic Abundance below Knee Energy) balloon experiment which uses nuclear track detectors. The final experiment goal is the determination of the charge spectrum of CR nuclei with Z $>$ 30 in the primary cosmic radiation. The detector, which has a geometric acceptance of $\\sim$ 1.7 m$^2$sr, was exposed in a trans-mediterranean stratospheric balloon flight. Calibrations of the detectors used (CR39 and Lexan), scanning strategies and algorithms for tracking particles in an automatic mode are presented. The present status of the results is discussed

  14. Angiography for renal artery stenosis: no additional impairment of renal function by angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Lufft, Volkmar; Fels, Lueder M.; Egbeyong-Baiyee, Daniel; Olbricht, Christoph J. [Abteilung Nephrologie, Medizinische Hochschule Hannover (Germany); Hoogestraat-Lufft, Linda; Galanski, Michael [Abteilung Diagnostische Radiologie, Medizinische Hochschule Hannover (Germany)

    2002-04-01

    The aim of this study was to compare renal function between patients with renal angiography and patients with renal angiography and angioplasty (AP) for renal artery stenosis (RAS). Forty-seven patients with suspected RAS were prospectively investigated by digital subtraction angiography (DSA) using non-ionic low osmolar contrast media (CM). In 22 patients RAS was detected and in 16 cases an angioplasty was performed in the same session. The following parameters were determined 1 day prior to and after the DSA, respectively: serum creatinine (S-Crea, {mu}mol/l) and single-shot inulin clearance (In-Cl, ml/min) for the evaluation of renal function; and urine alpha 1-microglobuline (AMG, {mu}g/g Crea) and beta-N-acetyl-glucoseaminidase (beta-NAG, U/g Crea) as markers of tubular toxicity. Serum creatinine was measured additionally 2 days after CM had been injected. In both groups with and without AP 174{+-}65 and 104{+-}56 ml of CM (p<0.0005) were used, respectively. There were no differences with regard to renal function or risk factors for CM nephrotoxicity between both groups. In the group with AP S-Crea and In-Cl (each: mean{+-}SD) did not change significantly (before DSA: 171{+-}158 and 61{+-}24, after DSA: 189{+-}177 and 61{+-}25, respectively), beta-NAG (median) rose from 4 to 14 (p<0.05) and AMG from 8 to 55 (n.s., because of high SD). In the group without AP S-Crea increased from 134{+-}109 to 141{+-}113 (p<0.01), In-Cl dropped from 65{+-}26 to 62{+-}26 (p<0,01), beta NAG (median) rose from 4 to 8 (p=0.01), and AMG from 7 to 10 (n.s.). A rise in baseline S-Crea by more than 25% or 44 {mu}mol/l occurred in 4 and 2 patients in the group with and without AP, respectively. Creatinine increase was reversible in all cases within 7 days. In this study using sensitive methods to detect changes of renal function and tubular toxicity no additional renal function impairment in DSA with angioplasty for RAS compared with DSA alone could be demonstrated. Our data suggest

  15. Long-term follow-up after embolization of pulmonary arteriovenous malformations with detachable silicone balloons

    DEFF Research Database (Denmark)

    Andersen, Poul Erik; Kjeldsen, Anette D

    2007-01-01

    ) with pulmonary angiography. Fifty-four percent of the balloons were deflated at latest radiographic chest film follow-up, but at pulmonary angiographic follow-up all embolized malformations were without flow irrespective of whether or not the balloons were visible. Detachable silicone balloons are not...

  16. Two cases of radiation-induced skin injury following percutaneous transluminal coronary angioplasty (PTCA)

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Chiho; Ichino, Naoki; Araki, Yoshiko; Mouri, Yuki; Yamatodani, Yoshiko [Minoo City Hospital, Osaka (Japan); Morikawa, Kaoru

    1999-02-01

    Two cases of radiation-induced skin injury following percutaneous transluminal coronary angioplasty (PTCA) are reported. Case 1 is a 52-year-old man who underwent PTCA for 7 times. Case 2 is a 67-year-old man who underwent PTCA for 5 times. In both cases, a cutaneous lesion developed into an ulcer over the right infrascapular region. The ulcer was treated surgically. The histopathological features were compatible with chronic radiation dermatitis. To avoid such injury in interventional procedures with long fluoroscopic time, it is very important for medical staffs to recognize the radiation-induced skin injury and to reduce the patient`s absorbed dose as much as possible. (author)

  17. Value of P-31 MR spectroscopy for percutaneous transluminal angioplasty of the iliofemoral arteries

    International Nuclear Information System (INIS)

    Phosphorus metabolism of the calf muscles has been determined by P-31 MR spectroscopy for evaluation of percutaneous transluminal angioplasty (PTA) of the lower extremities. Seventeen patients with atherosclerotic stenosis or occlusion of the iliac and femoral arteries underwent P-31 MR spectroscopy before and after PTA. Seven normal controls also underwent P-31 MRS of the lower extremities. The average ratio of β-adenosine triphosphate β-ATP), phosphocreatine (PCr), and inorganic phosphate (Pi) to the total signal per minute was compared. A 1.5-T superconductive MR unit was used. In patients with atherosclerotic disease, the ratio of β-ATP was lower before PTA at all measurement points before, during, and after exercise. A minimal drop in the values was observed with exercise, and the recovery was very slow after exercise

  18. Radionuclide examination of ischemic heart disease patients after percutaneous transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    Twenty five patients were examined prior to percutaneous transluminal coronary angioplasty (PTCA) and one week following it by exercise thallium scintigraphy, 6 of them were also examined summation radionuclide ventriculography. The results of the tests allowed to conclude that myocardial perfusion definitely improved in 18 patients, no change was found in 3 patients and a trend towards deterioration was recorded in 4 patients. The deteriorated or unchanged results of the radionuclide examinations could presumably be attributed to incomplete dilation of significant arterial stenosis, rapidly produced restenosis or extensive anatomical alteration in the coronary circulation. Best results were obtained when complete dilation could be achieved of the left anterior descending coronary artery in patients without any additional coronary artery lesions and myocardial infarction in their history. It was also found that growing experience of the PTCA team greatly improved the success rate of the procedure. (author). 4 figs., 2 tabs., 20 refs

  19. Long Duration Balloon flights development. (Italian Space Agency)

    Science.gov (United States)

    Peterzen, S.; Masi, S.; Dragoy, P.; Ibba, R.; Spoto, D.

    Stratospheric balloons are rapidly becoming the vehicle of choice for near space investigations and earth observations by a variety of science disciplines. With the ever increasing research into climatic change, earth observations, near space research and commercial component testing, instruments suspended from stratospheric balloons offer the science team a unique, stable and reusable platform that can circle the Earth in the polar region or equatorial zone for thirty days or more. The Italian Space Agency (ASI) in collaboration with Andoya Rocket Range (Andenes, Norway) has opened access in the far northern latitudes above 78º N from Longyearbyen, Svalbard. In 2006 the first Italian UltraLite Long Duration Balloon was launched from Baia Terra Nova, Mario Zuchelli station in Antarctica and now ASI is setting up for the their first equatorial stratospheric launch from their satellite receiving station and rocket launch site in Malindi, Kenya. For the equatorial missions we have analysed the statistical properties of trajectories considering the biennial oscillation and the seasonal effects of the stratospheric winds. Maintaining these launch sites offer the science community 3 point world coverage for heavy lift balloons as well as the rapidly deployed Ultra-light payloads and TM systems ASI developed to use for test platforms, micro experiments, as well as a comprehensive student pilot program. This paper discusses the development of the launch facilities and international LDB development.

  20. [Expansion dilatation balloons for cervical ripening in obstetric practice].

    Science.gov (United States)

    Ducarme, G; Grange, J; Vital, M

    2016-02-01

    During recent decades, mechanical devices have been substituted by pharmacological methods. Their place in the therapeutic arsenal remains important with a renewed obstetrical interest for these devices. Due to a lack of data they are still not recommended as first-line. This review thus attempted to examine the use of expansion dilatation balloons (Foley catheter and double-balloons) to analyze their effectiveness in case of native uterus and previous cesarean section. Twenty-seven clinical trials had compared balloons catheter and prostaglandins in patients without a history of uterine scar. The risk of cesarean section did not differ. Mechanical methods seemed to be more effective in achieving delivery within 24hours, with fewer episodes of excessive uterine contractions, but they necessitated more oxytocin during labor. Ten clinical trials analyzed dilatation balloons in patients with previous cesarean section. More than 70% women had favorable cervical ripening (Bishop score>6), and vaginal delivery was reported between 35 and 70% of patients. The risk of uterine rupture was low between 0.64 and 0.72%, with neither increased risk of severe neonatal and maternal morbidity nor increased risk of infectious morbidity. Mechanical methods are effective and safe for third trimester cervical ripening, mainly in women with previous cesarean section. Potential advantages may include wide availability and reduction of some of the side effects. PMID:26774842

  1. High-Altitude Balloon Observatories for Planetary Science

    Science.gov (United States)

    Arnold, S. P.; Tibor, K.; Cheng, A. F.; Hibbitts, C.; Young, E. F.; Andrews, J.; Landis, R.

    2013-12-01

    Recent studies have shown that progress can be made on over 20% of the key questions called out in the current Planetary Science Decadal Survey by a high-altitude balloon borne observatory. Therefore NASA has been assessing concepts for a gondola based observatory that would achieve the most possible science in a low risk and cost effective manner. As a first application of the concept, a stratospheric balloon mission to observe the newly discovered comet ISON is being developed and planned to fly in late 2013. This flight will demonstrate some of the characteristic features of balloon borne observatories and how those impact planetary science observations. That flight will result in mission proven instrument payloads which can be applied to future flights and science investigations. This paper documents the current status of stratospheric balloon applications to planetary science and some of the contributions that BRRISON will provide for a potential future planetary observatory system. The paper will also discuss the science benefits to be expected if larger aperture telescopes are flown, better pointing systems are realized, or different instruments are utilized with the telescopes. The paper concludes with a high level summary of ways to interface and utilize the potential platform for the readers own scientific interests.

  2. Meshed-Pumpkin Super-Pressure Balloon Design

    Science.gov (United States)

    Jones, Jack; Yavrouian, Andre

    2003-01-01

    An improved, lightweight design has been proposed for super-pressure balloons used to carry scientific instruments at high altitudes in the atmosphere of Earth for times as long as 100 days. [A super-pressure balloon is one in which the pressure of the buoyant gas (typically, helium) is kept somewhat above ambient pressure in order to maintain approximately constant density and thereby regulate the altitude.] The proposed design, called "meshed pumpkin," incorporates the basic concept of the pumpkin design, which is so named because of its appearance. The pumpkin design entails less weight than does a spherical design, and the meshed-pumpkin design would reduce weight further. The basic idea of the meshed-pumpkin design is to reinforce the membrane of a pumpkin balloon by attaching a strong, lightweight fabric mesh to its outer surface. The reinforcement would make it possible to reduce the membrane mass to one-third or less of that of the basic pumpkin design while retaining sufficient strength to enable the balloon to remain at approximately constant altitude for months.

  3. Balloon atrial septostomy under echocardiographic guide: case series

    Directory of Open Access Journals (Sweden)

    SM Meraji

    2012-12-01

    Full Text Available Background: Balloon atrial septostomy is an emergent procedure in pediatric cardiology. Nowadays, most patients in need of the procedure have acceptable outcomes after surgical repair. Thus, it is important to perform this procedure as safe as possible. By performing early arterial switch operation and prostaglandin infusion, the rate of balloon atrial septostomy has markedly decreased. However, not all centers performing early arterial switch repairs have abandoned atrial septostomy, even in patients who respond favorably to prostaglandin infusion.Case presentation: In total, eight 1- to 15-day old term neonates admitted in Shahid Rajaee Heart Center in Tehran, Iran from October 2009 to February 2011, with congenital heart diseases were scheduled for balloon atrial septostomy. In six cases the procedure was done exclusively under echocardiographic guidance and in two cases with the help of fluoroscopy. Success was defined as the creation of an atrial septal defect with a diameter equal to or more than 5 mm and ample mobility of its margins.Results: Male sex was predominant (87% and the mean age of the neonates was six days. The diagnosis in all cases was simple transposition of great arteries. The procedure was successful in all patients with any cardiovascular complication.Conclusion: Balloon atrial septostomy is an emergent procedure that can be done safely and effectively under echocardiographic guidance. According to the feasibility of this technique it could be performed fast, safe and effective at bedside, avoiding patient transportation to hemodynamic laboratory or referral center.

  4. [Intra-graft balloon pumping--a clinical case report].

    Science.gov (United States)

    Nagata, M; Tashiro, T; Tanaka, K; Haruta, Y; Todo, K

    1991-12-01

    A 29-year-old female underwent tube graft replacement of distal aortic arch and descending aorta for dissecting aneurysm. After 42 minutes of aortic cross-clamping the patient was initially weaned satisfactorily from cardiopulmonary bypass (CPB). However, cardiac arrhythmia and cardiac arrest necessitated reestablishment of CPB. Electro-cardiography showed inferior myocardial infarction. To wean CPB intraaortic balloon pumping (IABP) was mandatory. But because of dissecting aortic aneurysm IABP in conventional method was contra-indicated. Intra graft balloon pumping (IGBP) was initiated while the patient was on full CPB. A low-porosity woven Dacron tube graft (22 mm) was anastomosed end-to-side to ascending aorta. A balloon was inserted into the tube graft to establish IGBP. This IGBP provided effective circulatory assist. The patient was weaned from CPB 1 hours after reestablishment of IGBP. Postoperative course was stable. The patient was returned to the operating room for removal of the balloon 3 days postoperatively. We reported the case for whom IGBP was effective. IGBP was effective circulatory support for the patient when conventional use of IABP was contra-indicated. PMID:1774515

  5. Balloon-borne gamma-ray telescope with nuclear emulsion

    OpenAIRE

    Takahashi, Satoru; Group, for the Emulsion Gamma-ray Telescope

    2010-01-01

    By detecting the beginning of electron pairs with nuclear emulsion, precise gamma-ray direction and gamma-ray polarization can be detected. With recent advancement in emulsion scanning system, emulsion analyzing capability is becoming powerful. Now we are developing the balloon-borne gamma-ray telescope with nuclear emulsion. Overview and status of our telescope is described.

  6. Stability of infernal and ballooning modes in advanced tokamak scenarios

    NARCIS (Netherlands)

    Holties, H. A.; Huysmans, G. T. A.; Goedbloed, J. P.; Kerner, W.; Parail, V.V.; Soldner, F. X.

    1996-01-01

    A numerical parameter study has been performed in order to find MHD stable operating regimes for advanced tokamak experiments In this study we have concentrated on internal modes. Ballooning stability and stability with respect to infernal modes are considered. The calculations confirm that pressure

  7. 75 FR 77673 - National Environmental Policy Act: Scientific Balloon Program

    Science.gov (United States)

    2010-12-13

    ... E Street, SW., Washington, DC 20546-0001 (202-358-0168). On the Internet at: http://sites.wff.nasa... and draft FONSI on the Internet; 4. Consultations with Federal, State, and local agencies; and 5... positive economic impact each year during balloon campaigns at CSBF Fort Sumner from the purchase of...

  8. Balloon dilatation of the esophageal stricture in infants and children

    International Nuclear Information System (INIS)

    Balloon dilatation has been applied in treating of various pathologic narrowing of the hollow viscus. It is now accepted as a very effective modality especially in treating esophageal stenosis obviating surgical procedure. We performed 128 balloon dilatations in 29 patients with the number of dilatations in each patient ranging from once to 12 times. The age distribution of the patients was from 3 weeks to 6 years, with the median age of 3 months. Twenty nine patients consisted of 25 postoperative esophageal strictures (21 esophageal atresia with tracheoesophageal fistula, 1 congenital esophageal stenosis, 2 tracheobronchial remnant, and 1 congenital esophageal stenosis with esophageal atresia), 2 achalasia, 1 congenital esophageal stenosis, and 1 corrosive esophagitis. We had successful dilatation in 22 patients, who showed subsequent relief of symptoms and improvement in the diameter of stenotic segment. In 14 patients, esophageal perforation occurred during the procedure, one requiring emergency thoracotomy and the other three conservative management. Seven patients had no improvement in stenotic sites after several balloon dilatations. Failed cases were congenital stenosis, achalasia, corrosive esophagitis and four postoperative strictures. We believe that balloon dilatation is the procedure of choice in the treatment of postoperative esophageal stricture in infants and children and is a safe method as the perforation which can complicate the procedure could be managed conservatively

  9. Balloon dilatation of the esophageal stricture in infants and children

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Sung Wook; Kim, In One; Kim, Woo Sun; Yeon, Kyung Mo; Kim, Woo Ki; Park, Kwi Won; Han, Man Chung [Seoul Natioal University College of Medicine, Seoul (Korea, Republic of); Lee, Gi Jae [Inje University Paik Hospital, Seoul (Korea, Republic of); Yu, Pil Mun [Dankuk University College of Medicine, Seoul (Korea, Republic of)

    1992-09-15

    Balloon dilatation has been applied in treating of various pathologic narrowing of the hollow viscus. It is now accepted as a very effective modality especially in treating esophageal stenosis obviating surgical procedure. We performed 128 balloon dilatations in 29 patients with the number of dilatations in each patient ranging from once to 12 times. The age distribution of the patients was from 3 weeks to 6 years, with the median age of 3 months. Twenty nine patients consisted of 25 postoperative esophageal strictures (21 esophageal atresia with tracheoesophageal fistula, 1 congenital esophageal stenosis, 2 tracheobronchial remnant, and 1 congenital esophageal stenosis with esophageal atresia), 2 achalasia, 1 congenital esophageal stenosis, and 1 corrosive esophagitis. We had successful dilatation in 22 patients, who showed subsequent relief of symptoms and improvement in the diameter of stenotic segment. In 14 patients, esophageal perforation occurred during the procedure, one requiring emergency thoracotomy and the other three conservative management. Seven patients had no improvement in stenotic sites after several balloon dilatations. Failed cases were congenital stenosis, achalasia, corrosive esophagitis and four postoperative strictures. We believe that balloon dilatation is the procedure of choice in the treatment of postoperative esophageal stricture in infants and children and is a safe method as the perforation which can complicate the procedure could be managed conservatively.

  10. Scientific Ballooning Technologies Workshop STO-2 Thermal Design and Analysis

    Science.gov (United States)

    Ferguson, Doug

    2016-01-01

    The heritage thermal model for the full STO-2 (Stratospheric Terahertz Observatory II), vehicle has been updated to model the CSBF (Columbia Scientific Balloon Facility) SIP-14 (Scientific Instrument Package) in detail. Analysis of this model has been performed for the Antarctica FY2017 launch season. Model temperature predictions are compared to previous results from STO-2 review documents.

  11. Using Hydrogen Balloons to Display Metal Ion Spectra

    Science.gov (United States)

    Maynard, James H.

    2008-01-01

    We have optimized a procedure for igniting hydrogen-filled balloons containing metal salts to obtain the brightest possible flash while minimizing the quantity of airborne combustion products. We report air quality measurements in a lecture hall immediately after the demonstration. While we recommend that this demonstration be done outdoors or in…

  12. Balloon-assisted coiling through a 5-French system

    International Nuclear Information System (INIS)

    We present a catheter technique that utilizes a 5F system for the purpose of balloon-assisted coiling in the setting of intracranial aneurysms. A standard 5F short sheath is placed in the common femoral artery, and a 5F diagnostic catheter is placed through the sheath and used for selective vessel angiography. When endovascular intervention is pursued, the diagnostic catheter is placed in the appropriate vessel and systemic heparinization is ensured. Over an exchange length wire, the 5F vertebral catheter and 5F short sheath are exchanged for a 5F Shuttle (Cook) sheath. We then routinely place a 10, 14 or 18 microcatheter over an appropriately gauged microguidewire into the aneurysm. As needed, balloon catheters are then placed across the neck of the aneurysm for remodeling purposes. During the course of the procedure, control angiography is performed through the Shuttle sheath. Following the placement of coils, the microcatheter and balloon catheter are removed and a final biplane image is obtained via the 5F Shuttle sheath. This technique has been employed in 15 patients who required balloon-assisted coiling of an intracranial aneurysm. There were no technical difficulties or arterial access site complications from the procedures. Catheter mobility and torque were not affected, nor was the quality of our imaging. We conclude that this small-diameter system provides ample ''room'' for catheter placement and interventional treatment while reducing the known risks of postprocedural complications. Angiographic images remain excellent and are comparable to those obtained by larger catheters. (orig.)

  13. Determinants of success of coronary angioplasty in patients with a chronic total occlusion: a multiple logistic regression model to improve selection of patients.

    OpenAIRE

    Tan, K H; Sulke, N.; Taub, N A; Watts, E.; Karani, S.; Sowton, E

    1993-01-01

    OBJECTIVE--To study the determinants of success of coronary angioplasty in patients with chronic total occlusions, and to formulate a multiple logistic regression model to improve selection of patients. DESIGN--A retrospective analysis of clinical and angiographic data on a consecutive series of patients. PATIENTS--312 patients (mean age 55, range 31 to 79 years, 86% men) who underwent coronary angioplasty procedure for a chronic total occlusion between 1981 and 1992. RESULTS--Procedural succ...

  14. Stent-Graft for the Management of Hepatic Artery Rupture Subsequent to Transcatheter Thrombolysis and Angioplasty in a Liver Transplant Recipient

    International Nuclear Information System (INIS)

    Arterial rupture subsequent to angioplasty occurs in about 5% of cases. Thrombolysis with re-establishment of flow without resolving underlying anatomic defects such as hepatic arterial stenosis leads to re-thrombosis. We present a case of arterial anastomotic rupture after thrombolysis and angioplasty of an underlying anastomotic hepatic arterial stenosis. Both the underlying anatomic defect and the rupture were resolved successfully with placement of a stent-graft, with a resultant patent artery for 1 year after the procedure.

  15. Frequency and predictors for angiographically improved inflow of contrast medium after carotid angioplasty and stenting

    International Nuclear Information System (INIS)

    Percutaneous transluminal carotid angioplasty and stenting (PTAS) can result in immediate improvement in cerebral blood flow (CBF) evident through faster transit of contrast medium on angiography. To evaluate frequency and predictors of changes in inflow of contrast medium before and after PTAS, we reviewed 86 patients (mean age 68.6 ± 9.1 years) treated for symptomatic or asymptomatic carotid stenosis. Clinical data and lesion characteristics were extracted from charts and digital angiograms, respectively. Perfusion change was assessed qualitatively by comparing pre- and poststenting images matched for projection and time from injection. Improved inflow was defined on the basis of spatial or temporal distribution of contrast medium: grade -1: fewer vessels visible after stenting; 0: no change; 1: more distal small arteries visible; 2: time-matched poststenting image showing a capillary blush; 3: time-matched poststenting image showing small veins, 4 time-matched poststenting image showing large veins and sinuses. Faster inflow of contrast medium was observed in 74 % of patients (grades 1: 34 %,and 4: 4.7 %). In linear regression analysis, higher degrees of ipsilateral stenosis were associated with greater changes in inflow of contrast medium (P < 0.05). Right internal carotid lesions were associated with greater change in inflow than left-sided lesions (P < 0.01). In 31 patients (36 %) we initially showed contralateral anterior cerebral artery (ACA) filling, and in 39 % of these, normal filling was restored after stenting. Lesser contralateral carotid stenosis was associated with crossed ACA filling and with restoration of normal filling pattern after stenting. Faster appearance of a contrast-medium blush is seen in most cases of carotid angioplasty and stenting and depends on the degree of hemodynamic inflow obstruction relieved by stenting. (orig.)

  16. The influence of admission glucose on epicardial and microvascular flow after primary angioplasty

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Background Patients with elevated admission glucose levels may be at increased risk of death after myocardial infarction, independent of other baseline risk factors and more severe coronary artery disease. However, data regarding admission glucose and epicardial and microvascular flow after primary angioplasty is limited.Methods Angioplasty was performed in 308 ST-segment elevated myocardial infarction patients. Patients were divided into 3 groups on the basis of admission glucose level: group 1, <7.8 mmol/L; group 2, (7.8 - 11.0) mmol/L; and group 3, ≥11.0 mmol/L. Results Compared with group 1, patients in group 2 and group 3 were more often female and older. Triglycerides (TG) in group 3 were significantly higher than group 1. At angiography, they more frequently had 2-vessel or 3-vessel disease. In the infarct-related artery, there was no relationship between hyperglycemia and thrombolysis in myocardial infarction (TIMI) 3 flow after percutaneous coronary intervention (PCI) (89.7%, 86.0% and 86.3%, P=NS). However, corrected TIMI frame count (CTFC) in group 2 and group 3 were more than group 1. TIMI myocardial perfusion grade (TMPG) 0-1 grade among patients with hyperglycemia after PCI were more frequent (30.9% and 29.0% vs 17.3%, P<0.05). There was less frequent complete ST-segment resolution (STR) and early T wave inversion among patients with hyperglycemia after PCI. Conclusion Elevated admission glucose levels in ST-segment elevation myocardial infarction patients treated with primary PCI are independently associated with impaired microvascular flow. Abnormal microvascular flow may contribute at least in part to the poor outcomes observed in patients with elevated admission glucose.

  17. Outpatient angioplasty and stenting facilitated by percutaneous arterial suture closure devices

    International Nuclear Information System (INIS)

    Aim: To review our practice of outpatient percutaneous vascular interventions facilitated by an arterial suture device. Materials and methods: A retrospective review of all patients attending this tertiary centre for iliac or femoral intervention was undertaken between February 2001 and December 2004. All patients who underwent angioplasty or stenting had their puncture sites closed using a Perclose suture. Patients were kept flat for 15 min and allowed to fully mobilize at 60 min. Puncture sites were scored for visible bruising, haematoma and pain at discharge and on outpatient follow-up. Patient preference for future outpatient treatment was assessed. Results: Fifty-seven outpatients underwent 81 punctures. Forty-eight (84%) patients underwent iliac angioplasty; of those 42% underwent stent placement. Six patients (10%) required inpatient admission, five secondary to failed suture deployment. One patient had a non-closer-related puncture site intimal flap occlusion successfully repaired at surgery. Fifty-one (90%) patients discharged with a mean time of 157 min (60-280 min). Forty-six (92%) patients had no visible bruising or palpable haematoma on discharge. No patient had a haematoma greater than 2.5 cm. No discharged patient required readmission. Thirty percent reported a moderate to severe groin pain score (2-5/5) at discharge, increasing to 40% at follow-up. Forty-seven (98%) of the 48 patients, who expressed a preference, would be happy to undergo outpatient treatment again. Conclusion: Outpatient treatment is feasible, well tolerated and preferable to patients, but 10% will require inpatient admission. A planned post-procedure analgesia regimen or advice should be considered

  18. Patient Experience, Pain, and Quality of Life after Lower Limb Angioplasty: A Multisite Prospective Cohort Study

    Energy Technology Data Exchange (ETDEWEB)

    Culverwell, A. D., E-mail: adamculverwell@doctors.net.uk [Leeds General Infirmary (United Kingdom); Tapping, C. R.; Ettles, D. F. [Hull Royal Infirmary (United Kingdom); Kessel, D. [Leeds General Infirmary (United Kingdom)

    2012-08-15

    Purpose: To explore the experience of patients undergoing endovascular lower limb angioplasty and evaluate the improvements in quality of life and disease-related symptoms after the procedure. Methods: Patients completed a questionnaire before treatment and three questionnaires after the procedure (immediately after the procedure, and again 4 weeks and 3 months later). Anxiety, patient understanding, procedure-related pain, and disease-related pain were assessed by a visual analog score (VAS). Complications, analgesic requirements, and satisfaction were recorded. Changes to quality of life were assessed by the validated SF36 questionnaire. Results: A total of 88 patients (41%) responded. Overall, disease-related pain decreased over 3 months after the procedure. Smokers had more pain both before and after the procedure (P < 0.05). Explanation was considered better if provided by radiologist (P < 0.05). Sixty-nine percent of patients found the procedures less painful (mean VAS 2.5) than they had anticipated (VAS 5.5). Fifty percent of patients experienced adverse effects related to their puncture site, but this was highest among patients who had undergone the procedure before and smokers. The greatest quality-of-life improvements were in emotional and general health. Higher levels of disease-related pain were associated with worse general, emotional, and physical health (P < 0.05). Conclusion: Lower limb angioplasty provides symptomatic and quality-of-life improvements. Implementation of simple measures could improve patient satisfaction-for example, treatment should be explained by the radiologist in advance. Routine prescription of analgesics with particular attention to smokers and those undergoing repeat interventions is suggested.

  19. Lightweight Liquid Helium Dewar for High-Altitude Balloon Payloads

    Science.gov (United States)

    Kogut, Alan; James, Bryan; Fixsen, Dale

    2013-01-01

    Astrophysical observations at millimeter wavelengths require large (2-to-5- meter diameter) telescopes carried to altitudes above 35 km by scientific research balloons. The scientific performance is greatly enhanced if the telescope is cooled to temperatures below 10 K with no emissive windows between the telescope and the sky. Standard liquid helium bucket dewars can contain a suitable telescope for telescope diameter less than two meters. However, the mass of a dewar large enough to hold a 3-to-5-meter diameter telescope would exceed the balloon lift capacity. The solution is to separate the functions of cryogen storage and in-flight thermal isolation, utilizing the unique physical conditions at balloon altitudes. Conventional dewars are launched cold: the vacuum walls necessary for thermal isolation must also withstand the pressure gradient at sea level and are correspondingly thick and heavy. The pressure at 40 km is less than 0.3% of sea level: a dewar designed for use only at 40 km can use ultra thin walls to achieve significant reductions in mass. This innovation concerns new construction and operational techniques to produce a lightweight liquid helium bucket dewar. The dewar is intended for use on high-altitude balloon payloads. The mass is low enough to allow a large (3-to-5-meter) diameter dewar to fly at altitudes above 35 km on conventional scientific research balloons without exceeding the lift capability of the balloon. The lightweight dewar has thin (250- micron) stainless steel walls. The walls are too thin to support the pressure gradient at sea level: the dewar launches warm with the vacuum space vented continuously during ascent to eliminate any pressure gradient across the walls. A commercial 500-liter storage dewar maintains a reservoir of liquid helium within a minimal (hence low mass) volume. Once a 40-km altitude is reached, the valve venting the vacuum space of the bucket dewar is closed to seal the vacuum space. A vacuum pump then

  20. Comparative Efficacy of Pulse-Spray Thrombolysis and Angioplasty Versus Surgical Salvage Procedures for Treatment of Recurrent Occlusion of PTFE Dialysis Access Grafts

    International Nuclear Information System (INIS)

    Purpose: To compare the efficacy of surgery versus pulse-spray thrombolysis and angioplasty in patients with recurrent thrombosis of polytetrafluoroethylene (PTFE) dialysis access grafts. Methods: We analyzed 96 consecutive interventions for thrombosed PTFE dialysis access grafts in 18 patients. Primary patency after thrombolysis and angioplasty (n= 25) was compared with primary patency following thrombectomy alone (n= 50) or thrombectomy followed by graft revision (n= 21) using life-table analysis. A Cox proportional hazards model that accounted for graft age and number of previous interventions was used to generate the relative risk for recurrent occlusion following therapy. Results: Life-table analysis showed that patency after thrombolysis and angioplasty was greater than that following thrombectomy alone (p= 0.02). After accounting for the age of the graft and the number of previous interventions (average six per patient), the relative risk for recurrent occlusion [3.0; 95% confidence intervals (CI): 1.5, 6.4] was greater for thrombectomy alone than for thrombolysis/angioplasty [0.6; CI = 0.3, 1.3]. The relative risks of repeat occlusion following thrombolysis/angioplasty [0.6; CI = 0.3, 1.3] and thrombectomy/surgical revision [1.0; CI = 0.5, 1.7] were similar. Conclusion: Outcome data from our retrospective study on recurrent thrombosis of PTFE dialysis access grafts suggest that thrombolysis/angioplasty is superior to thrombectomy alone, and equivalent to thrombectomy/surgical revision

  1. Aggressive nonsurgical management of acute coronary artery occlusions developing immediately after percutaneous transluminal coronary angioplasty (PTCA)

    International Nuclear Information System (INIS)

    In 368 consecutive percutaneous transluminal coronary angiography (PTCA) procedures, acute occlusion of the dilated artery developed within the first hour after the procedure in 24 cases (6.5%). Four patients underwent emergency bypass surgery. In 17 of the remaining 20 patients, repeat balloon dilation was immediately attempted, and was successful in 11 instances (65%). Five of the six cases in which repeat balloon dilation was not successful responded well to surgical or medical therapy. The author conclude that acute occlusions of dilated coronary arteries shortly after PTCA do not automatically necessitate emergency bypass. Approximately two thirds of such cases can be managed by repeat dilation, converting a potential complication into a successful outcome

  2. Cryo-balloon catheter position planning using AFiT

    Science.gov (United States)

    Kleinoeder, Andreas; Brost, Alexander; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2012-02-01

    Atrial fibrillation (AFib) is the most common heart arrhythmia. In certain situations, it can result in life-threatening complications such as stroke and heart failure. For paroxsysmal AFib, pulmonary vein isolation (PVI) by catheter ablation is the recommended choice of treatment if drug therapy fails. During minimally invasive procedures, electrically active tissue around the pulmonary veins is destroyed by either applying heat or cryothermal energy to the tissue. The procedure is usually performed in electrophysiology labs under fluoroscopic guidance. Besides radio-frequency catheter ablation devices, so-called single-shot devices, e.g., the cryothermal balloon catheters, are receiving more and more interest in the electrophysiology (EP) community. Single-shot devices may be advantageous for certain cases, since they can simplify the creation of contiguous (gapless) lesion sets around the pulmonary vein which is needed to achieve PVI. In many cases, a 3-D (CT, MRI, or C-arm CT) image of a patient's left atrium is available. This data can then be used for planning purposes and for supporting catheter navigation during the procedure. Cryo-thermal balloon catheters are commercially available in two different sizes. We propose the Atrial Fibrillation Planning Tool (AFiT), which visualizes the segmented left atrium as well as multiple cryo-balloon catheters within a virtual reality, to find out how well cryo-balloons fit to the anatomy of a patient's left atrium. First evaluations have shown that AFiT helps physicians in two ways. First, they can better assess whether cryoballoon ablation or RF ablation is the treatment of choice at all. Second, they can select the proper-size cryo-balloon catheter with more confidence.

  3. Dosimetric fundamentals of endovascular brachytherapy using Re-188 to prevent restenosis after angioplasty

    International Nuclear Information System (INIS)

    Various radionuclides can be used for endovascular brachytherapy. A new concept is to inflate the balloon of a dilitation catheter with a radioactive solution. Re-188 can be eluated from a generator system and is available daily. The aim of this study was to obtain dosimetric data for this radionuclide. The dose decrease of Re-188 was calculated and measured with a TLD-system radial to a balloon catheter typically used in cardiology (diameter: 3 mm, length: 20 mm). Using a specific acitivity of 370 MBq/ml a dose of 0,3 Gy could be achieved within 1 min in a TLD in contact with the balloon. Paired TLDs differed about 3%. A fast dose reduction of 50% and 10% were stated within 0.5 mm and 2.5 mm, respectively. Calculated and measured values were in good agreement. The data are comparable to those known for Y-90. Calculations of dose distribution are consistent with TLD measurements of Re-188. Using a specific activity of 1.85 GBq/ml, a dose of 10-15 Gy at the coronary artery wall can be achieved within 2-3 min. (orig./MG)

  4. Fluorescence Lyman-Alpha Stratospheric Hygrometer (FLASH): application on meteorological balloons, long duration balloons and unmanned aerial vehicles.

    Science.gov (United States)

    Lykov, Alexey; Khaykin, Sergey; Yushkov, Vladimir; Efremov, Denis; Formanyuk, Ivan; Astakhov, Valeriy

    The FLASH instrument is based on the fluorescent method, which uses H2O molecules photodissociation at a wavelength lambda=121.6 nm (Lalpha - hydrogen emission) followed by the measurement of the fluorescence of excited OH radicals. The source of Lyman-alpha radiation is a hydrogen discharge lamp while the detector of OH fluorescence at 308 -316 nm is a photomultiplier run in photon counting mode. The intensity of the fluorescent light as well as the instrument readings is directly proportional to the water vapor mixing ratio under stratospheric conditions with negligible oxygen absorption. Initially designed for rocket-borne application, FLASH has evolved into a light-weight balloon sonde (FLASH-B) for measurements in the upper troposphere and stratosphere on board meteorological and small plastic balloons. This configuration has been used in over 100 soundings at numerous tropical mid-latitude and polar locations within various international field campaigns. An airborne version of FLASH instrument is successfully utilized onboard stratospheric M55-Geophysica aircraft and tropospheric airborne laboratory YAK42-Roshydromet. The hygrometer was modified for application onboard stratospheric long-duration balloons (FLASH-LDB version). This version was successfully used onboard CNES super-pressure balloon launched from SSC Esrange in March 2007 and flown during 10 days. Special design for polar long duration balloon PoGOLite was created for testing work during polar day in June 2013. Installation and measurement peculiarities as well as observational results are presented. Observations of water vapour using FLASH-B instrument, being of high quality are rather costly as the payload recovery is often complicated and most of the time impossible. Following the goal to find a cost-efficient solution, FLASH was adapted for use onboard Unmanned Aerial Vehicles (UAV). This solution was only possible thanks to compactness and light-weight (0.5 kg) of FLASH instrument. The

  5. Eventos adversos e motivos de descarte relacionados ao reuso de produtos médicos hospitalares em angioplastia coronária Adverse events and reasons for discard related to the reuse of cardiac catheters in percutaneous transluminal coronary angioplasty

    Directory of Open Access Journals (Sweden)

    Margarete Ártico Batista

    2006-09-01

    the brand-new and reuse of medical equipment. METHOD: Sixty patients were studied (48.3% with unstable angina, 45% with acute myocardial infarction and 6.7% with other diagnoses. During the procedure and stay in the Intensive Coronary Unit, the occurrence of fever, hypotension or hypertension, chills, sudoresis, bleeding, nausea and vomits were observed. Seven products were evaluated: catheter introducer, catheter guides (0.35 and 0.014, catheter balloons for angioplasty, indeflators and manifolds. In total, 76 brand-new and 410 reused apparatuses were studied to verify the occurrence of discard, whether this happened before or during the procedure and for what reasons. P-values < 0.05 were considered signicant. RESULTS: Twenty-six patients presented adverse effects. Hypotension was the most common seen in 11(18.3% cases. There was no significant association between this adverse effect and reuse or not of the equipment. Three brand-new products and 55 of the reused products were discarded as they were incomplete. CONCLUSION: The adverse effects presented by patients submitted to coronary vessel angioplasty were not associated to the reuse of the medical equipment. The integrity and functionality were the main reasons of discard.

  6. Percutaneous transluminal angioplasty of brachiocephalic arteries: Indications and long-term success in a series of 25 patients

    International Nuclear Information System (INIS)

    The clinical records and procedural details of 28 angioplasty procedures performed on 25 patients were reviewed. Long-term follow-up was conducted by examining the referring physicians' records and by direct telephone contact with the patient. Nine patients had neurologic symptoms only, eight patients had arm claudication symptoms only, seven patients had both neurologic and arm symptoms, and two patients underwent dilation procedures to provide graft inflow. Procedural complications were a stroke in the contralateral carotid distribution during follow-up thoracic aortography, and an embolus to the fifth digit (of no clinical significance). Long-term success of the angioplasty procedure did not correlate with initial symptoms, degree of stenosis, lesion length, or postangioplasty appearance. All patients with arm and neurologic symptoms and who were followed up for 3 years, with the exception of the patient who suffered a periprocedural stroke

  7. The exposure of radiologists and patients to radiation during coronary angiography and percutaneous transluminal coronary angioplasty (PTCA)

    International Nuclear Information System (INIS)

    The exposure of radiologists and patients to radiation during coronary angiography and percutaneous transluminal coronary angioplasty (PTCA) in Finland was studied using phantom measurements. Additional tests were made concerning the performance of TV fluoroscopy systems, cine fluorographic units and film processing. These tests include sensitometric quality control of film processing, automatic exposure control in fluoroscopy and cinefluorography, and contrast and resolution in a cine frame and TV image

  8. Gore-Tex small-vessel angioplasty: A suitable substitute for the use of autogenous saphenous vein grafts

    OpenAIRE

    Garcia-Rinaldi, Raul; Rea, John E.; Gallagher, Michael W.; Laevsky, Marlene J.; Ogburn, Michael; Porter, Robert H.

    1980-01-01

    Autogenous saphenous vein has been the material of choice for small-vessel angioplasty and for circulatory access graft reconstruction. In an effort to conserve autogenous saphenous vein, we used expanded polytetrafluoroethylene (PTFE) grafts in 45 patients over a 12-month period. We used Gore-Tex* to reconstruct 17 circulatory access grafts, 16 carotid arteries, two brachial arteries, seven femoral arteries, and three popliteal anterior or posterior tibial arteries. The indications for recon...

  9. Percutaneous transluminal angioplasty in a patient with internal carotid artery stenosis following gamma knife radiosurgery for recurrent pituitary adenoma

    OpenAIRE

    Hidemichi Ito; Hidetaka Onodera; Taigen Sase; Masashi Uchida; Hiroyuki Morishima; Kotaro Oshio; Takashi Shuto; Yuichiro Tanaka

    2015-01-01

    Background: Intracranial vascular complications following radiosurgery are extremely rare. Case Description: We report a case of stenosis in the internal carotid artery 5 years after gamma knife radiosurgery for a recurrent pituitary adenoma. Percutaneous transluminal angioplasty was performed successfully with anatomical and functional improvement. Conclusion: These results suggested the importance of monitoring for arterial stenosis in the long-term follow-up. Moreover, this is the ...

  10. The data processor of the EUSO-Balloon experiment

    International Nuclear Information System (INIS)

    The JEM-EUSO instrument is a wide-angle refractive telescope in near-ultraviolet wavelength region being proposed for attachment to the Japanese Experiment Module (JEM) onboard International Space Station (ISS). The main scientific goal of the mission is the study of Extreme Energy Cosmic Rays (EECR) above 5 × 1019 eV. The instrument consists of high transmittance optical Fresnel lenses with a diameter of 2.5 m, a focal surface covered by ∼ 5000 Multi Anode Photo Multiplier Tubes of 64 pixels, front-end readout, trigger and system electronics. The EUSO-Balloon experiment is a pathfinder mission in which a telescope of smaller dimension than the one designed for the ISS will be mounted onboard a stratospheric balloon. The main objective of this pathfinder mission, planned for 2014, is to perform a full scale end-to-end test of all the key technologies and instrumentation of JEM-EUSO detectors and to prove the global detection chain. Furthermore, EUSO-Balloon will measure the atmospheric and terrestrial UV background components, in different observational modes, fundamental for the development of the simulations. Through a series of stratospheric balloon flights performed by the French Space Agency CNES, EUSO-Balloon also has the potential to detect Extensive Air Showers from above, paving the way for any future large scale, space-based EECR observatory. In this paper we will present the Data Processor (DP) of EUSO-Balloon, which is the component of the Electronics System which performs the data management and the instrument control. More in detail, the DP controls the front-end electronics, performs the 2nd level trigger filtering, tags events with arrival time and payload position through a GPS system, manages the Mass Memory for data storage, measures live and dead time of the telescope, provides signals for time synchronization of the event, performs housekeeping monitor, and handles the interface to the telemetry system. The DP has to operate at high altitude

  11. Early intervention in acute myocardial infarction: significance for myocardial salvage of immediate intravenous streptokinase therapy followed by coronary angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Miller, H.I.; Almagor, Y.; Keren, G.; Chernilas, J.; Roth, A.; Eschar, Y.; Shapira, I.; Shargorodsky, B.; Berenfeld, D.; Laniado, S.

    1987-03-01

    Sixteen patients with acute myocardial infarction underwent treatment with streptokinase up to 3 hours after the onset of chest pain. Nine patients (group I) received streptokinase within 1 hour of the onset of pain, and seven patients (group II) received it within 2 to 3 hours. All underwent multigated radionuclide ventriculography after streptokinase therapy and 1 week later. Percutaneous transluminal coronary angioplasty of the infarct artery was performed within 24 hours in all patients. An effort-limited treadmill stress test was performed before discharge. There was no mortality or serious complication. Mean peak total creatine kinase was 521 +/- 289 mU/ml in group I, and 1,614 +/- 709 mU/ml in group II (p less than 0.05). The mean initial left ventricular ejection fraction was 47 +/- 11% in group I and 37 +/- 10% in group II. After early angioplasty (within 24 hours) and at 1 week recovery, left ventricular ejection fraction increased to 53 +/- 9% in group I (p less than 0.05) and to 40 +/- 7% in group II (p = NS). Seven of the nine patients in group I had normal radionuclide ventriculograms at discharge compared with none of the seven patients in group II. Thrombolytic therapy administered less than 1 hour after the onset of symptoms of acute myocardial infarction followed by angioplasty of the infarct artery results in preservation of left ventricular function, whereas therapy given after 2 hours has only a limited effect.

  12. Safety and efficacy of angioplasty with intracoronary stenting in patients with unstable coronary syndromes. Comparison with stable coronary syndromes

    Directory of Open Access Journals (Sweden)

    Luís C. L. Correia

    2000-06-01

    Full Text Available OBJECTIVE: To assess safety and efficacy of coronary angioplasty with stent implantation in unstable coronary syndromes. METHODS: Retrospective analysis of in-hospital and late evolution of 74 patients with unstable coronary syndromes (unstable angina or infarction without elevation of the ST segment undergoing coronary angioplasty with stent placement. These 74 patients were compared with 31 patients with stable coronary syndromes (stable angina or stable silent ischemia undergoing the same procedure. RESULTS: No death and no need for revascularization of the culprit artery occurred in the in-hospital phase. The incidences of acute non-Q-wave myocardial infarction were 1.4% and 3.2% (p=0.6 in the unstable and stable coronary syndrome groups, respectively. In the late follow-up (11.2±7.5 months, the incidences of these events combined were 5.7% in the unstable coronary syndrome group and 6.9% (p=0.8 in the stable coronary syndrome group. In the multivariate analysis, the only variable with a tendency to significance as an event predictor was diabetes mellitus (p=0.07; OR=5.2; 95% CI=0.9-29.9. CONCLUSION: The in-hospital and late evolutions of patients with unstable coronary syndrome undergoing angioplasty with intracoronary stent implantation are similar to those of the stable coronary syndrome group, suggesting that this procedure is safe and efficacious when performed in unstable coronary syndrome patients.

  13. Effects of Endovascular Brachytherapy with 192Ir Afterloading System on Expression of Type Ⅰ Collagen after Angioplasty

    Institute of Scientific and Technical Information of China (English)

    向定成; 杨传红; 候友贤; 龚志华; 易绍东; 邱建

    2003-01-01

    Objectives To investi-gate the effect and mechanism of endovascularbrachytherapy with 192Ir on expression of type Ⅰ collagen, metalloproteinases - 1 (MMP - 1) and the tissueinhibitor (TIMP- 1 ) after angioplasty. MethodsRestenotic model of domestic microswine was em-ployed and the iliac arteries were randomized to radi-ation group ( n = 12), which were treated with 20 ~ 25Gy of 192Ir, and non - radiation group ( n = 36) afterangioplasty. The target vessels were harvested in theend of 3 months and 6 months after angioplasty. Im-munohistochemistry and in situ hybridization were usedto detect proteins of type Ⅰ collagen, MMP-1 andTIMP- 1, and mRNA expression of type Ⅰ collagen.Results The protein and mRNA of type Ⅰ collagen,the ratios of TIMP-1/MMP-1 were significantlylower iu radiation group than in non- radiation group( P < 0.05 or 0.01 ). The peak of transcription of typeⅠ collagen mRNA was at 6 months and 3 months in non-radiation group and radiation group respectively.Conclusions Endovascular brachytherapy with192Ir might modify the metabolism of extracellular ma-trix after angioplasty by inhibiting the synthesis of typeⅠ collagen and the activities of MMP - 1 and TIMP - 1.

  14. Twenty-year evolution of Percutaneous coronary intervention and its impact on clinical outcomes a report from the NHLBI-sponsored, multicenter 1985–86 Percutaneous transluminal coronary angioplasty and 1997–2006 Dynamic Registries

    Science.gov (United States)

    Venkitachalam, Lakshmi; Kip, Kevin E; Selzer, Faith; Wilensky, Robert L; Slater, James; Mulukutla, Suresh R; Marroquin, Oscar C; Block, Peter C; Williams, David O; Kelsey, Sheryl F

    2009-01-01

    Background Percutaneous coronary intervention has undergone rapid progress both in technology and adjunct therapy. However, documentation of long-term temporal trends in relation to contemporary practice is lacking. Methods and Results We analyzed PCI use and outcomes in 8976 consecutive patients in the multicenter NHLBI-sponsored 1985–86 Percutaneous coronary transluminal coronary angioplasty (PTCA) and 1997–2006 Dynamic Registries waves [wave 1: 1997–98, bare metal stents; wave 2: 1999, uniform use of stents; wave 3: 2001–02, brachytherapy; waves 4 and 5: 2004–2006, drug-eluting stents]. Patients undergoing PCI in the recent waves were older and more often reported comorbidities than those in the balloon era. PCI was more often performed for acute coronary syndromes and, in spite of the greater disease burden, was more often selective. Procedural success was achieved and maintained more often in the stent era. Significant reductions were observed in in-hospital rates (%) of myocardial infarction (PTCA Registry: 4.9, wave 1: 2.7, wave 2: 2.8, wave 3: 1.9, wave 4: 2.6, wave 5: 2, Ptrend:<0.001) and emergency CABG (PTCA Registry: 3.7, wave 1: 0.4, wave 2: 0.4, wave 3: 0.3, wave 4:0.4, wave 5: 0, Ptrend:<0.001). Compared to the PTCA Registry, risk for repeat revascularization (31–365 days following index PCI) was significantly lower in the Dynamic waves (adjusted hazard ratio, wave 1: 0.72, wave 2: 0.51, wave 3: 0.51, wave 4: 0.30, wave 5: 0.36; P< 0.05 for all). Conclusion Percutaneous interventions, in the last two decades, has evolved to include more urgent, comorbid cases, yet achieving high success rates with significantly reduced need for repeat revascularization. PMID:20031687

  15. Stabilization of ballooning modes with sheared toroidal rotation

    International Nuclear Information System (INIS)

    A new code demonstrates the stabilization of MHD ballooning modes by sheared toroidal rotation. A shifted-circle model is used to elucidate the physics, and numerically reconstructed equilibria are used to analyze DIII-D discharges. In the ballooning representation, the modes shift periodically along the field line to the next point of unfavorable curvature. The shift frequency (dΩ/dq, where Ω is the angular toroidal velocity and q is the safety factor) is proportional to the rotation shear and inversely proportional to the magnetic shear. Stability improves with increasing shift frequency and, in the shifted circle model, direct stable access to the second stability regime occurs when this frequency is a fraction of the Alfven frequency, ωA = VA/qR. Shear stabilization is also demonstrated for an equilibrium reconstruction of a DIII-D VH-mode. (author). 9 refs, 3 figs

  16. The Balloon Experimental Twin Telescope for Infrared Interferometry

    Science.gov (United States)

    Rinehart, Stephen A.

    2008-01-01

    Astronomical studies at infrared wavelengths have dramatically improved our understanding of the universe, and observations with Spitzer, the upcoming Herschel mission, and SOFIA will continue to provide exciting new discoveries. The relatively low angular resolution of these missions, however, is insufficient to resolve the physical scales on which mid- to far-infrared emission arises, resulting in source and structure ambiguities that limit our ability to answer key science questions. Interferometry enables high angular resolution at these wavelengths, a powerful tool for scientific discovery, We will build the Balloon Experimental Twin Telescope for Infrared Interferometry (BETII), an eight-meter baseline Michelson stellar interferometer to fly on a high-altitude balloon. BETTII's spectral-spatial capability, provided by an instrument using double-Fourier techniques, will address key questions about the nature of disks in young star clusters and active galactic nuclei and the envelopes of evolved stars. BETTII will also lay the technological groundwork for future space interferometers,

  17. [Adherence and fidelity in patients treated with intragastric balloon].

    Science.gov (United States)

    Mazure, R A; Cancer, E; Martínez Olmos, M A; De Castro, M L; Abilés, V; Abilés, J; Bretón, I; Álvarez, V; Peláez, N; Culebras, J M

    2014-01-01

    A correct treatment of obesity needs a program of habits modification regardless of the selected technique, especially if it is minimally invasive as the intragastric balloon (BIG). The adherence of the obese patients with regard to recommended drugs measures to medium- and long-term is less than 50%. Given that the results obtained using the technique of gastric balloon must be seen influenced by adherence to the modification of habits program and its fulfillment, we reviewed series published in attention to the program proposed with the BIG. The series published to date provide few details about the used Therapeutic Programs as well as the adherence of patients to them, and even less concerning the Monitoring Plan and the loyalty of the patient can be seen. We conclude the convenience to agree on a follow-up strategy, at least the 6 months during which the BIG remain in the stomach. PMID:24483961

  18. Saturated gravity wave spectra measured with balloons in Mendoza (Argentina)

    Science.gov (United States)

    de la Torre, A.; Giraldez, A.; Alexander, P.

    1994-09-01

    Spectral results from a sounding of temperature and wind velocity between 11.9 and 23.1 km performed with an open type stratospheric balloon near the Andes Mountains, are reported. The use of this kind of balloons and high performance instruments, allowed to attain better spatial resolution (around 2.5 meters during the descent) than previous results and other sounding techniques. This high resolution permitted to study the complete interval of altitude data in three consecutive subintervals (below, around and above the tropopause). Each of these subintervals shows different saturation characteristics. Some differences have been found with the general pattern of power spectral densities reported by different theories. A large amplitude wave of around 1.8 km and possibly originated in the mountain relief, is clearly observed in the temperature, vertical and shear wind velocity components.

  19. Developing International Standards for Meteorological Balloon to Facilitate Industrial Progress

    Institute of Scientific and Technical Information of China (English)

    Deng Yizhi

    2011-01-01

    Meteorological balloon is made of natural rubber latex with a special process.On natural conditions,it carries the air sounding instrument into the high air to detect the meteorological elements in the air.As a means of delivery used in the aerological sounding,it is widely used in the meteorological,sailing,aeronautical,aerospace and other fields,and plays an extremely important role in the weather report,disaster prevention,disaster relief,guaranteeing ships and aircrafts to leave ports safely,and scientific research in relevant spaces,etc.Especially,the role of meteorological balloons is not ignorable in the forecast of extremely adverse weather frequently occurring around the world in recent years.

  20. Designing the Balloon Experimental Twin Telescope for Infrared Interferometry

    Science.gov (United States)

    Rinehart, Stephen

    2011-01-01

    While infrared astronomy has revolutionized our understanding of galaxies, stars, and planets, further progress on major questions is stymied by the inescapable fact that the spatial resolution of single-aperture telescopes degrades at long wavelengths. The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-meter boom interferometer to operate in the FIR (30-90 micron) on a high altitude balloon. The long baseline will provide unprecedented angular resolution (approx. 5") in this band. In order for BETTII to be successful, the gondola must be designed carefully to provide a high level of stability with optics designed to send a collimated beam into the cryogenic instrument. We present results from the first 5 months of design effort for BETTII. Over this short period of time, we have made significant progress and are on track to complete the design of BETTII during this year.