Sample records for angiography intrakranielle mr-angiographie

  1. Abdominal MR angiography

    International Nuclear Information System (INIS)

    Wegmueller, H.; Vock, P.

    1993-01-01

    The two techniques currently most often used for MR angiography, those based on time-of-flight effects and on phase-contrast, are introduced, and our results with three-dimensional phase contrast angiography of the abdomen are presented. Several basic differences from other imaging procedures render MR angiography clinically useful for screening for renal artery stenosis in critical situations, such as renal failure or intolerance to contrast agents. In the future, the spectrum of applications of MR angiography will broaden and include other indications, such as portal venous hypertension and follow-up studies after surgical portal systemic shunting. (orig.) [de

  2. Intracranial MR angiography

    International Nuclear Information System (INIS)

    Davis, W.L.; Blatter, D.D.; Parker, D.L.; Robison, R.O.; Harnsberger, H.R.

    1991-01-01

    This paper compares the more traditional three-dimensional (3D) time-of-flight MR angiography with a novel new technique, MOTSA, in the evaluation of both normal and abnormal intracranial anatomy. The authors performed sequential, location-matched 3D TOF and MOTSA MR angiography in 10 subjects with normal and 25 with abnormal intracranial anatomy. Images were evaluated for visualization of specific vessels and depiction of pathologic anatomy. All images were subjected to an objective scoring system. Digital angiography was available in 15 of 25 abnormal cases. In the normal cases, large- and small-vessel visualization was improved. Significant improvement in visualization of venous anatomy was also observed. In the abnormal cases, pathologic anatomy was better visualized, providing important diagnostic information. Multiple overlapping thin-slab-acquisition MR angiography demonstrates vessel visualization that is increased over that of 3D TOF MR angiography in both normal and abnormal cases. Because of the decrease in saturation effects and phase dispersion, MOTSA is especially useful in the evaluation of complex intracranial vascular abnormalities

  3. MR angiography with Vasovist

    Energy Technology Data Exchange (ETDEWEB)

    Goyen, Mathias [University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20251 Hamburg (Germany)], E-mail: goyen@uke.uni-hamburg.de

    2007-12-15

    Vasovist (Gadofosveset) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. This blood pool contrast agent reversibly binds to albumin providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive clinical and pre-clinical testing to evaluate the safety and efficacy of the drug. The clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (aorto-iliac, renal, pedal), examination of potential drug interaction with warfarin, and comparison with X-ray angiography. The clinical trials show that Vasovist-enhanced MR angiography is safe and well tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. This review article highlights the product characteristics of Vasovist, gives an overview of the clinical development program and discusses selected clinical applications.

  4. MR angiography with Vasovist

    International Nuclear Information System (INIS)

    Goyen, Mathias

    2007-01-01

    Vasovist (Gadofosveset) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. This blood pool contrast agent reversibly binds to albumin providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive clinical and pre-clinical testing to evaluate the safety and efficacy of the drug. The clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (aorto-iliac, renal, pedal), examination of potential drug interaction with warfarin, and comparison with X-ray angiography. The clinical trials show that Vasovist-enhanced MR angiography is safe and well tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. This review article highlights the product characteristics of Vasovist, gives an overview of the clinical development program and discusses selected clinical applications

  5. Contrast-enhanced MR angiography in Leriche's syndrome

    International Nuclear Information System (INIS)

    Link, J.; Steffens, J.C.; Brossmann, J.; Heller, M.; Loose, R.

    1998-01-01

    Purpose: To determine the usefulness of contrast-enhanced MR angiography for the diagnosis of Leriche's syndrome. Material and methods: Leriche's syndrome was seen in 7 patients via DSA. In [dition, contrast-enhanced MR angiography was performed (T R 7.8 ms/T E 2.1 ms, flip angle 30 , slab thickness 116 mm, slice thickness 1.82 mm, 64 partitions, FOV 500x438 mm, matrix 224x512). Results: Diagnosis of Leriche's syndrome was possible by contrast-enhanced MR angiography in each case. Visualisation of the femoral arteries was not possible in two patients by intraarterial DSA, in three other patients there was an insufficient contrast in the femoral arteries with DSA. Contrast-enhanced MR angiography revealed good visualisation of the femoral arteries in these patients. In [dition, contrast-enhanced MR angiography allowed complete visualisation of the patent lower limb arteries. In intraarterial DSA visualisation of the lower limb arteries was achieved reached in only one patient, but was incomplete. Conclusion: Contrast-enhanced MR angiography yielded the correct diagnosis of Leriche's syndrome in all 7 patients. Contrast-enhanced MR angiography was superior to DSA in the assessment of the distal run-off vessels in five of seven patients. (orig.) [de

  6. MR angiography in pediatric neurological disorders

    International Nuclear Information System (INIS)

    Lee, B.C.P.; Park, T.S.; Kaufman, B.A.

    1995-01-01

    MR angiography using 3D and 2D time-of-flight techniques were used to evaluate pediatric neurological disorders. MRA (arteriography) and MRV (venography) were abnormal in 63 and 45 cases, respectively. Conventional cerebral angiography was performed in 30 cases. These techniques were compared with MRI and conventional angiography. In addition, the value of MR angiography for surgical planning was subjectively evaluated. Our results showed that intracranial vessels were invariably better shown on MR angiography than on MRI. MRA and MRV were most useful in evaluating vascular distortions related to congenital brain malformations and intracranial tumors. MRA was valuable in detecting arterial narrowing but overestimated the degree of stenosis compared with conventional angiography. MRV was the technique of choice for evaluation of dural sinus and cerebral venous thrombosis and compression. MRA played little to no role in preoperative planning of vascular malformations and aneurysms. It did not appear to be accurate in assessing tumor vascularity or lesions in small arteries and arteritis. (orig.)

  7. Vasovist-enhanced MR angiography

    International Nuclear Information System (INIS)

    Goyen, M.; Shamsi, K.; Schoenberg, S.O.

    2006-01-01

    Vasovist (MS-325) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. Vasovist reversibly binds to albumin, providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive testing to evaluate the safety and efficacy of the drug; the clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (AIOD, renal, pedal), examination of potential drug interaction with warfarin and comparison with XRA. The clinical trials show that Vasovist-enhanced MR angiography is safe and well-tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. (orig.)

  8. Vasovist-enhanced MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Goyen, M. [Univ. Medical Center, Hamburg-Eppendorf, Hamburg (Germany); Shamsi, K. [Berlex Lab., Inc., Montville, NJ (United States); Schoenberg, S.O. [Dept. of Clinical Radiology, Univ. Hospitals Grosshadern, Munich (Germany)

    2006-02-15

    Vasovist (MS-325) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. Vasovist reversibly binds to albumin, providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive testing to evaluate the safety and efficacy of the drug; the clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (AIOD, renal, pedal), examination of potential drug interaction with warfarin and comparison with XRA. The clinical trials show that Vasovist-enhanced MR angiography is safe and well-tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. (orig.)

  9. Evaluation of the pedal artery: comparison of three-dimensional gadolinium-enhanced MR angiography with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Kang, Sung Gwon; Byun, Joo Nam; Kim, Young Cheol; Choi, Jeong Yeol; Kim, Dong Hyun [College of Medicine, Chosun Univ., Kwangju (Korea, Republic of)

    2002-07-01

    To compare the three-dimensional gadolinium-enhanced MR angiography with digital subtraction angiography (DSA) for evaluation of the pedal artery. In 12 extremities of 11 patients, both digital subtraction angiography (DSA) and contrast-enhanced MR angiography (CE-MR angiography) were performed during the same week. Among ten of the 11 patients, the following conditions were present: atherosclerosis (n=4), diabetic foot (n=3), Buerger's disease (n=1), calciphylactic arteriopathy (n=1) and arteriovenous malformation of the foot (n=1). The remaining patient underwent angiography prior to flap surgery. For MR angiography, a 1.5T system using an extremity or head coil was used. A three-dimensional FISP (fast imaging with steady state precession) sequence was obtained before enhancement, followed by four sequential acquisitions (scan time, 20 secs, scan interval time, 10 secs) 10 seconds after intravenous bolus injection of normal saline (total 10 cc), following intravenous administration of gadolinium (0.02 mmol/kg, 3 ml/sec). Arterial segments of the ankle and foot were classified as the anterior or posterior tibial artery, the distal peroneal artery, the medial or lateral plantar artery, the pedal arch, and the dorsalis pedis artery. Two radiologists independently analysed visualization of each arteraial segment and the mean of visible arterial segments in one extreminty using CE-MR angiography and DSA. Among 84 arterial segments, 16 were invisible at both CE-MR angiography and DSA, while 39 were demonstrated by both modalities. Twenty-six segments were visible only at CE-MR angiography and three only at DSA. CE-MR angiography displayed a higher number of arterial segments than DSA (mean, 5.42 vs. mean 3.50, respectively), a difference which was statistically significant (p<0.000). The difference between each arterial segment was not statistically significant, except for the dorsalis pedis artery (t test, p<0.000). In that it provides additional information for

  10. Gadolinium-enhanced MR angiography of arterial occlusive disease in lower extremity : comparison with conventional digital subtraction angiography

    International Nuclear Information System (INIS)

    Shin, Sang June; Koh, Young Hwan; Cha, Joo Hee; Kim, Hyu Beom; Chung, Jin Wook; Park, Jae Hyung

    2000-01-01

    To compare the diagnostic value of gadolinium-enhanced MR angiography with that of conventional digital subtraction angiography for the evaluation of lower extremity arterial occlusive diseases. In 26 patients with symptomatic lower extremity arterial occlusive disease, both conventional digital subtraction angiography (DSA) and gadolinium-enhanced MR angiography (CE-MRA) were performed during the same week. MR angiography was performed using three-dimensional gradient-echo acquisition before, and two sequential acquisitions after, the administration of gadolinium (0.2 mmol/kg). In 23 patients, two separate, contiguous areas were scanned using additional doses. In three patients, only one field with a suspicious lesion was scanned. Three radiologists independently analyzed the CE-MRA and DSA findings of each vascular segment (20 segments per arterial tree) for the presence of obstructive lesions; the grade assigned was either mild or none (less than 50%), stenotic (50%-99%), or occlusion (100%). From among a total of 462 segments, DSA detected 99 which were significantly narrowed (stenosis, 33; occlusion, 66). Using MR angiography, 102 segments (stenosis 39; occlusion, 63) were identified, and 94 lesions (stenosis, 32; occlusion, 62) were graded correctly. Seven lesions were overestimated and four were underestimated. For the detection of hemodynamically significant stenosis or occlusions using MR angiography, sensitivity, specificity, and diagnostic accuracy were 95%, 98%, and 98% (G=3D0.995, P less than 0.001), respectively. To prove the absence of lesions, we repeated DSA in two patients with arterial spasm due to puncture. Three occluded segments seen on DSA, which revealed intact segments on MR angiography, suggested slow distal flow after reconstitution. For the evaluation of lower extremity arterial occlusive disease, the diagnostic value of gadolinium-enhanced MR angiography is comparable with that of digital subtraction angiography. The advantages of the

  11. Correlation of angiography and MR imaging in cerebral vasculitis

    International Nuclear Information System (INIS)

    Cloft, H.J.; Phillips, C.D.; Dix, J.E.; McNulty, B.C.; Kallmes, D.F.; Zagardo, M.T.

    1999-01-01

    Purpose: MR imaging and cerebral angiography were correlated in patients with primary angiitis of the central nervous system (PACNS) to assess the relative roles of these imaging modalities in the diagnosis. Material and Methods: In 9 patients, MR imaging and angiography were compared with regard to the relative involvement of each major vascular territory. Vascular territories assessed were the anterior, middle, and posterior cerebral arteries, and the posterior fossa. Results: All patients had angiographic findings consistent with vasculitis in multiple vascular territories. MR findings ranged from normal to diffusely abnormal. One patient had a completely normal MR investigation. Of 50 territories affected by vasculitis on angiography, 17 (34%) were normal on MR. Conclusion: Relative to cerebral angiography, MR imaging is a poor indicator of the presence or absence of PACNS. Angiography is indicated when clinical suspicion of PACNS is strong, regardless of the findings on MR. (orig.)

  12. MR angiography (MRA)

    Energy Technology Data Exchange (ETDEWEB)

    Hasuo, Kanehiro [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1995-12-01

    The primary goal of vascular imaging is the visualization of morphology and hemodynamics. Catheter angiography has been regarded as a gold standard for this purpose. However, MR angiography (MRA) is now increasingly being recognized as an important noninvasive technique for the depiction of vascular diseases and is partially superseding catheter angiography. The author evaluated the usefulness of MRA in the diagnosis of cerebral aneurysms and moyamoya disease. All aneurysms 5 mm or larger in diameter could be detected and most of those less than 5 mm in diameter were also detectable with using a combination of MIP images, target MIP images and source images. In moyamoya disease, the diagnosis could be made in all. For hemodynamic changes, flow directions in the circle of Willis could be visualized by phase-contrast MRA in a normal volunteer. In addition, MRA successfully showed the patency of surgical collaterals in cases of moyamoya disease. Despite some limitations compared with catheter angiography, MRA has a high sensitivity and specificity in the diagnosis of cerebrovascular abnormalities. Furthermore, screening of cerebral aneurysms or cerebrovascular occlusive diseases seems to be a new, and important indication for MRA. (author).

  13. CT and MR angiography

    International Nuclear Information System (INIS)

    Bert, A.L.; Marshal, G.

    1995-01-01

    CT-angiography is a new vessel imaging technique based on the volumetric scanning of the region of interst during the first pass of IV bolus injection of contrast medium. MR-angiography is a titally noninvasive technique. The differentiation of flowing blood from the adjecent stationary tissues is based on the detection of blood motion. The flowing blood is highlighted with white light. CT- and MR-angiographic techniques are used to establish% stenoses and occlusions in intracranial arteries; aneurisms; trombosis of intracranial veins and venous angioma; diseases of neck vessels, thoracic vessels, abdominal vessels. Blood flow direction in cirrotic patients with portal hypertension can be determined in the portal vein, as well as the presence of thrombosis

  14. Value of MR-angiography in brain infarction

    International Nuclear Information System (INIS)

    Pirronello, Veronica; Capizzano, Aristides A.; Chouela, Carolina L.; Ternak, Alejandro; Ramirez, Susana; Mazzuco, Juan C.

    2004-01-01

    A retrospective study has been performed in a series of 237 patients, with brain and neck MR and MR angiography techniques. 108/237 (45.5%) patients presented either hemorrhage or lacunar and non lacunar ischemic stroke, 67 of which showed restricted diffusion. Diffusion and perfusion techniques can significantly contribute to study acute stroke. In our series MR angiography showed a 4% sensitivity to detect small arteries pathology. (author)

  15. Breath-hold two-dimensional MR angiography of coronary arteries. Comparison with conventional coronary angiography in ten cases

    International Nuclear Information System (INIS)

    Li Liwei; Zhang Wanshi; Liu Chaozhong; Lu Xiaoyan; Xu Jiaxing

    1997-01-01

    Purpose: To assess the diagnostic value of two-dimensional coronary magnetic resonance (MR) angiography in patients evaluated for ischemic heart disease. Materials and methods: Ten patients who underwent selective cardiac catheterization with coronary MR angiography were evaluated with two-dimensional coronary MR angiography. Coronary MR angiography was performed with breath-hold fat-suppressed ECG-gated Turbo-FLASH with K-space segmentation using a 1.5 T imager. Results: The left main coronary artery, proximal left anterior descending artery, circumflex artery and right coronary artery were demonstrated in all cases. Continuous segments (mean) of left anterior descending, circumflex and right coronary arteries visualized on MRA were 6.72 +- 3.16 cm, 3.67 +- 4.81 cm and 7.93 +- 3.12 cm respectively. The overall sensitivity for detection of hemodynamically significant coronary artery lesion (≥50%) was 62.5% respectively. Conclusion: Breath-hold two-dimensional coronary MR angiography was useful in showing relatively long segments of the main coronary arteries and also has potential in depicting hemodynamically significant coronary artery lesions

  16. MR angiography of the TMJ in asymptomatic volunteers

    International Nuclear Information System (INIS)

    Takagi, Ritsuo; Ohashi, Yasushi; Westesson, P.L.; Togashi, Hirosuke

    1998-01-01

    To evaluate the vascular anatomy of the temporomandibular joint (TMJ) and surrounding soft tissue non-invasively, we applied magnetic resonance (MR) angiography for delineating the arterial architecture around the TMJ. MR angiograms of the left and right TMJs in asymptomatic volunteers were obtained using 3D/Time-of-flight (TOF) (First Field Echo, TR/TE/FLIP=46 ms/6.8 ms/17 deg) with intravenous contrast. These MR angiograms were compared with experimental angiograms of human TMJ autopsy specimens in order to identify each of the branches of the arteries on the MR angiograms. This study enabled the depiction by MR angiography of arterial vessels around the TMJ region to some degree. In conclusion, MR angiography appears promising as a non-invasive tool to evaluate the vascular anatomy of the TMJ. (author)

  17. Electrocardiographically gated snapshot MR angiography

    International Nuclear Information System (INIS)

    Brown, D.G.; Holsinger, A.E.; Riederer, S.J.

    1990-01-01

    The purpose of this paper is to evaluate the effectiveness of applying ultrashort (∼12 msec) TR times and measuring the central phase encodings first in improving the accuracy of vascular depiction in MR angiography. The imaging method combines ultrashort TR imaging techniques with time-of-flight MR angiography. The central phase-encoding views are acquired first, and an inversion-recovery contrast preparation pulse is applied prior to image acquisition to null signal from static tissues. In initial studies, the method was tested on phantoms and volunteers. The contrast-preparation phase effectively nulls static spins at the start of image acquisition. During the TL period fresh blood flows into the imaging section; even slowly moving blood is fully replaced

  18. MR and angiography: Evaluation of the hemodynamics of portal hypertension

    International Nuclear Information System (INIS)

    Torres, W.E.; Gaylord, G.M.; Whitmire, L.; Chuang, V.P.; Bernardino, M.E.

    1986-01-01

    Forty-two MR imaging examinations and angiographic procedures in 38 patients with portal hypertension were compared for how well the images depicted portal perfusion and direction of flow, portal vein thrombosis, and the presence and type of shunt. Thirty-three MR imaging studies indicated grade I or II portal flow. In 29 cases portal flow was grade I or II by angiography; in the remaining cases the flow was grade IV. In a total of eight cases portal flow was grade IV by angiography, but none appeared to be grade IV on MR imaging. Both MR imaging and angiography detected portal vein thrombosis (41 of 42 cases). MR imaging and angiography agreed as to whether a shunt was present or absent, and patent or occluded (41 of 42 cases). Currently, MR imaging is an unsatisfactory modality by which to grade portal flow. MR imaging does depict portal vein thrombosis well, and can be used to determine patency of surgical shunts

  19. Rapid line scan MR angiography

    International Nuclear Information System (INIS)

    Frahm, J.; Merboldt, K.D.; Hanicke, W.; Bruhn, H.

    1987-01-01

    Direct MR angiography may be performed using line scan imaging techniques combined with presaturation of stationary spins. Thus, a single line scan echo yields a projection of vessels due to the signal from reflowing unsaturated spins. Reconstruction of an angiographic image is performed line by line at slightly incremented positions. In particular, line scan angiography is direct and fast without a sensitivity to artifacts even for high flow rates. Image resolution and field of view may be chosen without restrictions, and zoom images using enhanced gradients may be recorded without aliasing artifacts. The method is robust with respect to eddy currents and pulsatile flow. Line scan MR angiograms of phantoms, animals, and human volunteers have been recorded using 90 0 radio frequency pulses and gradient-recalled echoes

  20. Contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Bosmans, H.; Marchal, G.

    1996-01-01

    Despite many optimizations, the current limitations of plain MR angiography include: Saturation that impairs the visualization of veins and arteries with slow flow and spin-dephasing signal voids in locations with turbulent flow. Recently, the use of contrast agents has been proposed to cope with these remaining problems. Because of induced shortening of the T1 of the blood, saturation in the blood vessels is overcome. As a result, arteries and veins are visualized with the same signal intensity, which makes the technique less flow-dependent. In combination with short T1-weighted acquisitions, today CE MRA can be obtained while the patient is holding his breath. This last approach is most promising for abdominal applications since the respiratory motion can be frozen. As these acquisitions also use very short echo times, spin dephasing can be reduced. In conclusion, the use of contrast agents has greatly increased the clinical usefulness of MR angiography. (orig.) [de

  1. MR imaging and MR angiography in popliteal artery entrapment syndrome

    International Nuclear Information System (INIS)

    Atilla, S.; Akpek, S.; Yuecel, C.; Tali, E.T.; Isik, S.; Ilgit, E.T.

    1998-01-01

    Popliteal artery entrapment (PAE) syndrome is an uncommon congenital anomaly seen in young adults causing ischemic symptoms in the lower extremities. It is the result of various types of anomalous relationships between the popliteal artery and the neighboring muscular structures. The purpose of this study was to define the role of MR imaging combined with MR angiography in the diagnosis of PAE cases. Four cases with segmental occlusion and medial displacement of popliteal artery in digital subtraction angiography (DSA) examinations were diagnosed as PAE syndrome by MR imaging and MR angiography. The DSA and MRA images are compared. All of the cases showed various degrees of abnormal intercondylar insertion of the medial head of the gastrocnemius muscle. The MR images showed detailed anatomy of the region revealing the cause of the arterial entrapment. Subclassification of the cases were done and fat tissue filling the normal localization of the muscle was evaluated. The DSA and MRA images demonstrated the length and localization of the occluded segment and collateral vascular developments equally. It is concluded that angiographic evaluation alone in PAE syndrome might result in overlooking the underlying cause of the arterial occlusion, which in turn leads to unsuccessful therapy procedures such as balloon angioplasty. Magnetic resonance imaging combined with MR angiography demonstrates both the vascular anatomy and the variations in the muscular structures in the popliteal fossa successfully, and this combination seems to be the most effective way of evaluating young adults with ischemic symptoms suggesting PAE syndrome. (orig.)

  2. Usefulness of MR angiography in renal tumor

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Toshitsugu; Morimoto, Kouji; Nishimura, Kenji; Tsujimura, Akira; Yasunaga, Yutaka; Matsumiya, Kiyomi; Takaha, Minato (Osaka National Hospital (Japan))

    1992-11-01

    MR angiography using a gradient-echo, pulse sequence FLASH (fast, low-angle shot) method during breath-hold with a MAGNETOM H-15 scanner (1.5 Tesla; Siemens Medical System) was performed on 27 patients with renal tumor at our clinic between Feburary 20, 1990 and September 30, 1991 and we studied to evaluate its usefulness. Of these 27 patients, 22 patients including one patient under hemodialysis treatment had renal cell carcinoma and one patient had oncocytoma pathologically proven from the excised specimens. The remaining four patients including two patients associated with inferior vena cava tumor thrombus were clinically diagnosed as renal cell carcinoma based on the result of imaging examinations such as excretory urography, ultrasonography, computed tomography and conventional angiography. However, they could not be operated on because their tumors were too advanced. By reconstruction of the data of consecutive coronal scans of the abdominal blood vessels such as the abdominal aorta, inferior vena cava and renal arteries and veins simultaneously without any intravenous contrast materials. Our present study revealed that MR angiography has some advantages, especially with regard to preoperative angiographic information about the abdomen of patients with renal tumor. That is, MR angiography can delineate many kinds of arteries and veins of the abdomen simultaneously and in a broader range, as well as it can be performed on the patients with hypersensitivity to iodinate contrast materials or renal insufficiency in a usual fashion. Furthermore, our present study suggested that the MR angiography is useful for assessing the presence and extent of inferior vena caval tumor thrombus of renal cell carcinoma and for clearly distinguishing tumor lesion and the surrounding normal renal parenchyma in the patients with renal tumor. (author).

  3. Usefulness of MR angiography in renal tumor

    International Nuclear Information System (INIS)

    Oka, Toshitsugu; Morimoto, Kouji; Nishimura, Kenji; Tsujimura, Akira; Yasunaga, Yutaka; Matsumiya, Kiyomi; Takaha, Minato

    1992-01-01

    MR angiography using a gradient-echo, pulse sequence FLASH (fast, low-angle shot) method during breath-hold with a 'MAGNETOM H-15' scanner (1.5 Tesla; Siemens Medical System) was performed on 27 patients with renal tumor at our clinic between Feburary 20, 1990 and September 30, 1991 and we studied to evaluate its usefulness. Of these 27 patients, 22 patients including one patient under hemodialysis treatment had renal cell carcinoma and one patient had oncocytoma pathologically proven from the excised specimens. The remaining four patients including two patients associated with inferior vena cava tumor thrombus were clinically diagnosed as renal cell carcinoma based on the result of imaging examinations such as excretory urography, ultrasonography, computed tomography and conventional angiography. However, they could not be operated on because their tumors were too advanced. By reconstruction of the data of consecutive coronal scans of the abdominal blood vessels such as the abdominal aorta, inferior vena cava and renal arteries and veins simultaneously without any intravenous contrast materials. Our present study revealed that MR angiography has some advantages, especially with regard to preoperative angiographic information about the abdomen of patients with renal tumor. That is, MR angiography can delineate many kinds of arteries and veins of the abdomen simultaneously and in a broader range, as well as it can be performed on the patients with hypersensitivity to iodinate contrast materials or renal insufficiency in a usual fashion. Furthermore, our present study suggested that the MR angiography is useful for assessing the presence and extent of inferior vena caval tumor thrombus of renal cell carcinoma and for clearly distinguishing tumor lesion and the surrounding normal renal parenchyma in the patients with renal tumor. (author)

  4. Clinical application of pelvic MR angiography for gynecologic diseases

    Energy Technology Data Exchange (ETDEWEB)

    Ohnishi, Takeshi [Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1996-08-01

    Magnetic resonance (MR) imaging is the second most important method next to the ultrasound for the diagnosis of gynecological disorders. MR angiography provides a new noninvasive method for evaluating vascular occlusive disease of the lower extremities and the branches of abdominal aorta. To our knowledge, no determinant of efficacy of MR angiography and images of gynecological diseases have yet been made. Maximum intensity projection image was obtained from the data set by the three dimensional contrast enhanced MR angiography (3D-CE MRA) with newly designed fat suppression method. MR angiogram reveals well visualization of lower abdominal aorta and its branches. Furthermore, uterine arteries were identified in 49.3% of the cases, branching from the internal iliac artery. Leiomyoma of the uterus showed an enhanced uterus in 53.7% of the eases. All cases of endometriosis demonstrated a homogeneous, high signal intensity being a specific finding. In conclusion, maximum intensity projection image of pelvis showed a good visualization of the lower abdominal aorta and its branches. Uterine artery and, in a few cases, ovarian artery can be demonstrated on MR angiography. All cases of endometriosis showed a significant, high signal intensity. This technique is noninvasive and be a supplementary method for diagnosis and follow up of vasculature of gynecological disorders. (author)

  5. Clinical application of pelvic MR angiography for gynecologic diseases

    International Nuclear Information System (INIS)

    Ohnishi, Takeshi

    1996-01-01

    Magnetic resonance (MR) imaging is the second most important method next to the ultrasound for the diagnosis of gynecological disorders. MR angiography provides a new noninvasive method for evaluating vascular occlusive disease of the lower extremities and the branches of abdominal aorta. To our knowledge, no determinant of efficacy of MR angiography and images of gynecological diseases have yet been made. Maximum intensity projection image was obtained from the data set by the three dimensional contrast enhanced MR angiography (3D-CE MRA) with newly designed fat suppression method. MR angiogram reveals well visualization of lower abdominal aorta and its branches. Furthermore, uterine arteries were identified in 49.3% of the cases, branching from the internal iliac artery. Leiomyoma of the uterus showed an enhanced uterus in 53.7% of the eases. All cases of endometriosis demonstrated a homogeneous, high signal intensity being a specific finding. In conclusion, maximum intensity projection image of pelvis showed a good visualization of the lower abdominal aorta and its branches. Uterine artery and, in a few cases, ovarian artery can be demonstrated on MR angiography. All cases of endometriosis showed a significant, high signal intensity. This technique is noninvasive and be a supplementary method for diagnosis and follow up of vasculature of gynecological disorders. (author)

  6. MR-angiography

    International Nuclear Information System (INIS)

    Seiderer, M.

    1989-01-01

    Three categories of MRI techniques for vascular imaging are discussed: 2d-angiography using rephasing and dephasing pulse sequences and slice selective imaging; 3d-angiography using rehpasing and dephasing pulse sequences and fas 3d-imaging techniques; 3d-angiography using signal intensity modulation caused by pre- and post-contrast data acquisition (e.g. Gadolinium-DTPA) in combination with fast 3d-imaging (only one type of pulse sequence). (H.W.). 6 figs

  7. MR inflow angiography for the evaluation of dural sinus patency

    International Nuclear Information System (INIS)

    Poncelet, B.; Baleriaux, D.; Grand, C.; Van Dijk, P.; De Graaf, R.; Segebarth, C.

    1990-01-01

    This paper assesses dural sinus patency with two-dimensional inflow MR angiography. Twelve patients with potential dural sinus (superior sagittal and transverse sinus) involvement related to tumors of the falx or the convexity (meningiomas, metastasis) were examined with digital subtraction angiography (DSA), Mr imaging (1.5-T Gyroscan system), including T1-weighted (pre- and post-agadolinium) and T2-weighted spin-echo imaging, and MR angiography. For the MR angiographic study, a gradient-echo fast field echo sequence with flow compensation was used. Thin (2-mm), contiguous coronal or transverse sections were acquired sequentially. Three-dimensional reconstruction with MIP processing was then performed. CT, DSA, and MR imaging were performed for presurgical evaluation. Surgical confirmation of sinus patency was obtained for all patients

  8. Prospective comparison of MR angiography and color duplex US with conventional angiography for peripheral arterial occlusive disease

    International Nuclear Information System (INIS)

    Mulligan, S.A.; Matsuda, T.; Lanzer, P.; Gross, G.; Routh, W.; Keller, F.; Koslin, D.B.; Berland, L.; Fields, M.; Doyle, M.; Cranney, G.; Lee, J.; Pohost, G.

    1990-01-01

    This paper evaluates color Doppler US (CDUS) and MR angiographic (MRA) assessment of peripheral vascular disease of the lower extremities, using blinded prospective comparison with conventional angiography. Conventional angiography, two-dimensional inflow MRA, and CDUS were performed in 12 patients. Four diagnostic categories were used to grade arterial lesions by evaluating peak velocity. Revascularization interventions were planned by the vascular surgeon, blinded from the imaging method utilized and from data derived from CDUS, MRA, and conventional angiography

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of ...

  10. MR angiography in the diagnosis of tumors in the head and neck

    International Nuclear Information System (INIS)

    Vogl, T.J.; Balzer, J.O.; Juergens, M.; Lissner, J.; Grevers, G.

    1992-01-01

    40 normal individuals and 153 patients with lesions in the head and neck were examined by conventional imaging methods and by means of MR angiography (1.5 Tesla Magnetome). The problems to be solved concerned the ralationship between tumors and vessels and vascular anomalies and abnormalities at the skull base (56 cases), the facial skeleton (62 cases) and the neck (35 cases). Digital subtraction angiography was performed in 54 patients and the findings corelated with MR angiography. Optimal results were obtained by using a FISP 3D sequence; in this way arterial structures could be rendered reproducibly down to a diameter of 2 mm. The venous system in the head and neck was best shown by a FLASH 2D sequence. Correlation with arterial DSA showed high accuracy of MR angiography (91%) concerning displacement of vessels, the topography and the recognition of vascular occlusions. Our results indicate that MR angiography is a rapid and reliable procedure for evaluating the arterial and venous changes due to tumors in the head and neck region. (orig.) [de

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic ... called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a catheter makes it ...

  13. Feasibility of MR-guided angioplasty of femoral artery stenoses using real-time imaging and intraarterial contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Paetzel, C.; Zorger, N.; Bachthaler, M.; Voelk, M.; Seitz, J.; Herold, T.; Feuerbach, S.; Lenhart, M.; Nitz, W.R.

    2004-01-01

    Purpose: To show the feasibility of magnetic resonance (MR) for guided interventional therapy of femoral and popliteal artery stenoses with commercially available materials supported by MR real-time imaging and intraarterial MR angiography. Materials and Methods: Three patients (1 female, 2 male), suffering from symptomatic arterial occlusive disease with stenoses of the femoral (n=2) or popliteal (n=1) arteries were included. Intraarterial digital subtraction angiography was performed in each patient pre- and post-interventionally as standard of reference to quantify stenoses. The degree of the stenoses reached from 71-88%. The MR images were acquired on a 1.5 T MR scanner (Magnetom Sonata; Siemens, Erlangen, Germany). For MR-angiography, a Flash 3D sequence was utilized following injection of 5 mL diluted gadodiamide (Omniscan; Amersham Buchler, Braunschweig, Germany) via the arterial access. Two maximum intensity projections (MIP) were used as road maps and localizer for the interactive positioning of a continuously running 2D-FLASH sequence with a temporal solution of 2 images per second. During the intervention, an MR compatible monitor provided the image display inside the scanner room. Safety guidelines were followed during imaging in the presence of a conductive guidewire. The lesion was crossed by a commercially available balloon catheter (Wanda, Boston Scientific; Ratingen, Germany), which was mounted on a 0.035'' guidewire (Terumo; Leuven, Belgium). The visibility was provided by radiopaque markers embedded in the balloon and was improved by injection of 1 mL gadodiamide into the balloon. After dilation, the result was checked by intraarterial MR angiography and catheter angiography. Results: The stenoses could be correctly localized by intraarterial MR angiography. There was complete correlation between intraarterial MR angiography and digital subtraction angiography. The combination of guidewire and balloon was visible and the balloon was placed

  14. MR angiography

    International Nuclear Information System (INIS)

    Masaryk, T.J.; Ross, J.S.

    1991-01-01

    This paper reports on preliminary research and recent clinical experience which indicates that MR angiography can play a role in routine scanning by providing useful information regarding the anatomy of the cerebral circulation. Used in conjunction with conventional spin-echo studies it may improve the overall sensitivity and specificity of MRI in a cost-effective fashion. It does not, however, replace conventional arteriography at this time for either extracranial or intracranial disease. The use of intravascular contrast agents with new fast-scan techniques also provides dynamic information regarding tissue perfusion in a fashion analogous to that of xenon CT. While this work is preliminary, and the exact agents and mathematical models have yet to be defined, the ability to perform parenchymal, angiographic, and physiologic imaging at a single setting is potentially very powerful. Clearly, the role of MR flow techniques deserves further investigation into possible technical refinements, so that accuracy relative to other diagnostic studies and impact upon patient management can be assessed in a meaningful way

  15. MR angiography in diagnosing and following up the treatment result: arteria lusoria

    International Nuclear Information System (INIS)

    Vogl, T.J.; Juergens, M.; Harms, J.; Pegios, W.; Zimmermann, A.; Hetzer, R.; Felix, R.

    1994-01-01

    Diagnostic and therapeutic procedures are presented in a 29-year-old female patient who suffered from severe dysphagia and rapid loss in weight. In the conventional X-ray examination and barium swallow an aberrant right subclavian artery was suspected. MR imaging (MRI) and MR angiography (MRA) were done to plan the surgical correction. Post-operative MRA documented exactly the complex topography after surgical correction and the flow pattern in the implanted Gore-Tex stretch graft prosthesis. Non-invasive MR angiography renders possible the concrete planning of complex corrections of thoracic vessels replacing invasive catheter angiography. (orig.) [de

  16. MR angiography of eddy-current-free MR imaging system with a 3T permanent magnet

    International Nuclear Information System (INIS)

    Nishimura, H.; Watanabe, S.; Takeuchi, H.

    1991-01-01

    This paper reports that, the authors main purpose was to evaluate two-dimensional time flight MR angiography in the visualization of vascular structure by using an eddy-current-free 0.3-T permanent magnet MR imaging system. The authors have developed multisection acquisition technique for two-dimensional time-of-flight MR angiography with the use of velocity-compensated gradient echoes. MR angiograms were obtained with a ray-tracing algorithm of the new modified maximum intensity projection at various viewing angles. These angiograms are displayed on cathode-ray tubes in a high-speed cyclic mode to depict the front-rear relation of vessels for better recognition. With an eddy-current-free permanent magnet system, two-dimensional time-of-flight angiography could clearly depict intracranial vascular structure, cervical vessels, and vessels of the extremities with thin-section (2 or 3 mm) acquisition. A high flip angle (90 degrees) with a short TR enabled better differentiation between blood flow and stationary tissues. Stenosis of the carotids could be detected in accordance with digital subtraction angiography

  17. Software-triggered contrast-enhanced three-dimensional MR angiography of the intracranial arteries.

    Science.gov (United States)

    Isoda, H; Takehara, Y; Isogai, S; Takeda, H; Tanaka, T; Takahashi, M; Nozaki, A; Sun, Y

    2000-02-01

    We investigated the effectiveness of software-triggered contrast-enhanced three-dimensional (3D) MR angiography in evaluating intracranial arteries. We studied 38 patients with suspected brain lesions. Imaging was performed using a 1.5-T superconducting MR system with a commercially available head coil. To monitor signal intensity changes we used software to place a tracker volume at the basilar artery or the internal carotid artery. A 20-ml bolus of gadodiamide hydrate was administered through the antecubital vein at a rate of 2-4 ml/sec, followed by a saline flush. Three-dimensional MR angiography using a spoiled gradient-echo sequence with centric K-space ordering was triggered by the arrival of the contrast bolus in the tracker volume. Imaging times ranged from 12 to 20 sec. We used MR images to assess the effectiveness of contrast-enhanced 3D MR angiography in revealing intracranial arteries with minimal venous overlap. The software triggered imaging on the arrival of the contrast bolus in 81.6% of examinations. In 77.6% of examinations, the resulting MR angiograms revealed intracranial arteries with minimal venous overlap. Software-triggered contrast-enhanced 3D MR angiography with centric K-space ordering is a promising technique for viewing intracranial arteries.

  18. Acute chest pain: The role of MR imaging and MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Hunold, Peter, E-mail: peter.hunold@uk-sh.de [Clinic for Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23538 Lübeck (Germany); Bischoff, Peter, E-mail: peter.bischoff@uk-sh.de [Clinic for Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23538 Lübeck (Germany); Barkhausen, Jörg, E-mail: joerg.barkhausen@uk-sh.de [Clinic for Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23538 Lübeck (Germany); Vogt, Florian M., E-mail: florian.vogt@uk-sh.de [Clinic for Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23538 Lübeck (Germany)

    2012-12-15

    MR imaging (MRI) and MR angiography (MRA) have gained a high level of diagnostic accuracy in cardiovascular disease. MRI in cardiac disease has been established as the non-invasive standard of reference in many pathologies. However, in acute chest pain the situation is somewhat special since many of the patients presenting in the emergency department suffer from potentially life-threatening disease including acute coronary syndrome, pulmonary embolism, and acute aortic syndrome. Those patients need a fast and definitive evaluation under continuous monitoring of vital parameters. Due to those requirements MRI seems to be less suitable compared to X-ray coronary angiography and multislice computed tomography angiography (CTA). However, MRI allows for a comprehensive assessment of all clinically stable patients providing unique information on the cardiovascular system including ischemia, inflammation and function. Furthermore, MRI and MRA are considered the method of choice in patients with contraindications to CTA and for regular follow-up in known aortic disease. This review addresses specific features of MRI and MRA for different cardiovascular conditions presenting with acute chest pain.

  19. Comparison between fast contrast-enhanced MR angiography and DSA in diagnosing spinal cord vascular malformations

    International Nuclear Information System (INIS)

    Wang Wu; Li Minghua; Fang Chun; Wang Jue; Xiao Yunfeng

    2007-01-01

    Objective: To evaluate the diagnostic and clinical value of fast contrast-enhanced MR angiography (CE-MRA) with elliptic centric phase-encoding in spinal cord vascular malformations. Methods Fast three-dimensional contrast-enhanced MR angiography with elliptic centric phase-encoding and superconducting 1.5T system was applied prospectively in twenty-five consecutive patients with clinically suspected of spinal cord vascular malformations. All cases were performed with selective spinal digital subtraction angiography, including 18 cases treated by surgery and 2 of them with embolization before surgery, MR angiography follow up were undertaken in ten patients after surgery. Comparing fast contrast-enhanced MR angiography with DSA in diagnosing spinal cord vascular malformations included the origin of feeding artery, the feeding artery, the fistula or the nidus, the draining vein, and the vessel image quality based on the gold standard of selective spinal digital subtraction angiography. Results: Surgically proven diseases included spinal arteriovenous malformations(3 cases), spinal cord perimedullary arteriovenous fistulas (5 cases), spinal dural arteriovenous fistulas (8 cases), paravertebral arteriovenous fistulas (1 case), and spontaneous spinal epidural hematomas (2 eases). Comparing with DSA, the accuracy of MR angiography in diagnosing spinal cord vascular malformations; and detecting the origin of the feeding artery, the feeding artery, the shunt or the nidus and the draining vein were 93.8%, 92%, 96.2%, 100% and 100%, respectively. Overall the degree vascular enhencement were judged to be similar(P>0.05), but the vessel continuity of MRA was inferior to DSA (P<0.05). However, 9 cases of MRA showed no abnormal vascular malformation coinciding with those of surgery. Posttreatment MR angiography did not depict any abnormal vessels again. Conclusions: Fast three-dimensional contrast-enhanced MR angiography with elliptic centric phase-encoding may provide

  20. Three-Dimensional Respiratory-Gated Coronary Mr Angiography with Reference to X-Ray Coronary Angiography

    International Nuclear Information System (INIS)

    Ikonen, A. E. J.; Manninen, H. I.; Vainio, P.; Vanninen, R. L.; Matsi, P. J.; Soimakallio, S.; Hirvonen, T.P.J.; Hartikainen, J.E.K.

    2003-01-01

    Purpose: To assess the clinical value of three-dimensional coronary MR angiography (CMRA) in the detection of significant coronary artery stenosis using conventional X-ray angiography as the standard reference. Material and Methods: Sixty-nine patients underwent X-ray coronary angiography and CMRA because of suspected or previously diagnosed coronary artery disease. MRI was performed with a 1.5-T whole body imaging system using ECG-triggered 3D gradient echo sequence with retrospective navigator echo respiratory gating and fat suppression. Results: A total of 276 coronary artery segments were analyzed. The X-ray coronary angiography was normal in 22 patients. Significant proximal stenoses (exceeding 50%) or occlusions were present in 102 coronary artery segments. In all, 120 stenoses or occlusions were identified in CMRA. Sixteen percent of the coronary artery segments had to be excluded because of poor image quality. The overall sensitivity and specificity for MRA for identification of significant stenosis were 75% and 62%, respectively. CMRA correctly detected 89% of patients with at least one vessel disease, but 6 patients with coronary artery disease would have been missed. Conclusions: Because of the high data exclusion and false-negative case rate, CMRA with retrospective navigator echo triggering is at present not suitable as a clinical screening method in coronary artery disease

  1. Collateral vessels in moyamoya disease : comparison of MR and MRA with conventional angiography

    International Nuclear Information System (INIS)

    Shim, Joo Eun; Yoon, Dae Young; Yi, Jeong Geun; Kim, Ho Chul; Choi, Chul Sun; Bae, Sang Hoon

    1998-01-01

    To determine the value of magnetic resonance imaging (MR) and magnetic resonance angiography (MRA) in assessing collateral vessels of moyamoya disease. Twenty-four patients with moyamoya disease who underwent MR, 3D TOF MRA, and conventional angiography participated in this study. Two radiologists working independently and with no knowledge of the angiographic findings, interpreted the MR and MRA images. To determine the presence of parenchymal and leptomeningeal collaterals (48 hemispheres) and transdural collaterals (38 hemispheres in 19 patients were depicted by angiography of the external carotid), the findings were compared with those of angiography. Parenchymal, leptomeningeal, and transdural collaterals were depicted by conventional angiography in 34 (71%), 32 (67%), and 11 (29%) hemispheres respectively. The sensitivity and specificity of MR/MRA for collateral vessels were 79.1/88.1 % for parenchymal collaterals, 72.1/88.1 % for leptomeningeal collaterals, and 0.1/18.1 % for transdural collaterals, respectively. Respective sensitivity and specificity of MR/MRA were 88.94/94.1% for leptomeningeal collaterals, and 18.93/55.1 % for transdural collaterals, when the prominent posterior cerebral and external carotid artery were regarded as secondary signs of leptomeningeal and transdural collateral vessels. In moyamoya disease, MR and MRA are useful imaging modalities for the assessment of collateral vessels. The prominent posterior cerebral artery and external carotid artery can be useful secondary signs of leptomeningeal and transdural collateral vessels. (author). 18 refs., 2 figs

  2. Pediatric head and neck lesions: assessment of vascularity by MR digital subtraction angiography.

    Science.gov (United States)

    Chooi, Weng Kong; Woodhouse, Neil; Coley, Stuart C; Griffiths, Paul D

    2004-08-01

    Pediatric head and neck lesions can be difficult to characterize on clinical grounds alone. We investigated the use of dynamic MR digital subtraction angiography as a noninvasive adjunct for the assessment of the vascularity of these abnormalities. Twelve patients (age range, 2 days to 16 years) with known or suspected vascular abnormalities were studied. Routine MR imaging, time-of-flight MR angiography, and MR digital subtraction angiography were performed in all patients. The dynamic sequence was acquired in two planes at one frame per second by using a thick section (6-10 cm) selective radio-frequency spoiled fast gradient-echo sequence and an IV administered bolus of contrast material. The images were subtracted from a preliminary mask sequence and viewed as a video-inverted cine loop. In all cases, MR digital subtraction angiography was successfully performed. The technique showed the following: 1) slow flow lesions (two choroidal angiomas, eyelid hemangioma, and scalp venous malformation); 2) high flow lesions that were not always suspected by clinical examination alone (parotid hemangioma, scalp, occipital, and eyelid arteriovenous malformations plus a palatal teratoma); 3) a hypovascular tumor for which a biopsy could be safely performed (Burkitt lymphoma); and 4) a hypervascular tumor of the palate (cystic teratoma). Our early experience suggests that MR digital subtraction angiography can be reliably performed in children of all ages without complication. The technique provided a noninvasive assessment of the vascularity of each lesion that could not always have been predicted on the basis of clinical examination or routine MR imaging alone.

  3. MR angiography of in situ and transplanted renal arteries

    International Nuclear Information System (INIS)

    Smith, H.J.; Bakke, S.J.

    1993-01-01

    Three-dimensional (3D) time-of-flight (TOF) MR angiography (MRA) was performed in 34 patients with suspected renal artery disease. In situ (i.e., nontransplanted) renal arteries were studied with MRA in 14 patients. Of these, 12 had conventional angiography for comparison. Twenty-four MRAs of transplanted renal arteries were obtained in 20 patients; 8 of these had angiography as well. Significant stenoses of in situ renal arteries were diagnosed with a sensitivity of 100% and a specificity of 95%. The stenoses were all proximal; 3D TOF MRA proved inadequate for depiction of peripheral renal arteries. MRA and angiography showed good agreement between findings in 7 of 8 patients with renal transplants. In one patient with a renal transplant, MRA showed a significant stenosis of the arterial anastomosis which appeared completely normal at i.a. DSA, indicating that findings at MRA still need to be confirmed by more established alternative methods. (orig.)

  4. Nonenhanced MR angiography techniques

    International Nuclear Information System (INIS)

    Lanzman, R.S.; Kroepil, P.; Blondin, D.; Schmitt, P.

    2011-01-01

    Especially in regard to the potential risks for the development of nephrogenic systemic fibrosis (NSF) following the administration of Gadolinium-based contrast material, nonenhanced MR angiography (MRA) methods are becoming ever more important. Besides well-established time-of-flight (TOF) and phase-contrast (PC) MRA, alternative imaging techniques based on balanced steady-state free precession (bSSFP) and turbo-spin-echo (TSE) sequences are increasingly used in combination with or without arterial spin labeling (ASL) strategies. This article provides an overview of the principles and clinical values of different nonenhanced MRA techniques. In addition, recent nonenhanced MRA developments are presented. (orig.)

  5. MR imaging and MR angiography in preoperative evaluation of intracranial meningiomas

    International Nuclear Information System (INIS)

    Goldmann, A.; Kunz, U.; Bader, C.; Leibing, U.; Friedrich, J.M.; Oldenkott, P.

    1994-01-01

    A group of 41 patients with intracranial meningiomas were examined by MR imaging (MRI) and MR angiography (MRA) to assess the clinical value of MRA in the preoperative evaluation of these patients. The results of MRA were compared with the results of intraarterial cerebral catheter X-ray angiography (XRA; n 19) and with the operative findings (n = 41). Our results showed a good correlation between MRA and XRA/surgery in demonstrating the relationship between the tumor and adjacent venous and arterial structures. Use of MRA was also helpful in demonstrating the degree of intrinsic tumor vascularity. It also supplied important information for operative planning. Adjunct XRA was mandatory if detailed information about tumor-feeding vessels was requested by the neurosurgeon, especially in highly vascularized angiomatous meningiomas and in meningiomas suspected of tumor feeding by vessels of the internal carotid artery. (orig.)

  6. MR imaging and MR angiography in preoperative evaluation of intracranial meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Goldmann, A. [Dept. of Diagnostic Radiology, Univ. of Ulm (Germany); Kunz, U. [Dept. of Neurosurgery, Military Hospital, Academic Hospital of the University, Ulm (Germany); Bader, C. [Dept. of Diagnostic Radiology, Univ. of Ulm (Germany); Leibing, U. [Dept. of Diagnostic Radiology, Univ. of Ulm (Germany); Friedrich, J.M. [Dept. of Diagnostic Radiology, Univ. of Ulm (Germany); Oldenkott, P. [Dept. of Neurosurgery, Military Hospital, Academic Hospital of the University, Ulm (Germany)

    1994-12-01

    A group of 41 patients with intracranial meningiomas were examined by MR imaging (MRI) and MR angiography (MRA) to assess the clinical value of MRA in the preoperative evaluation of these patients. The results of MRA were compared with the results of intraarterial cerebral catheter X-ray angiography (XRA; n = 19) and with the operative findings (n = 41). Our results showed a good correlation between MRA and XRA/surgery in demonstrating the relationship between the tumor and adjacent venous and arterial structures. Use of MRA was also helpful in demonstrating the degree of intrinsic tumor vascularity. It also supplied important information for operative planning. Adjunct XRA was mandatory if detailed information about tumor-feeding vessels was requested by the neurosurgeon, especially in highly vascularized angiomatous meningiomas and in meningiomas suspected of tumor feeding by vessels of the internal carotid artery. (orig.)

  7. 2D MR angiography of the aortic aneurysm

    International Nuclear Information System (INIS)

    Amanuma, Makoto; Hasegawa, Makoto; Watabe, Tsuneya; Heshiki, Atsuko

    1992-01-01

    2D time-of-flight MR angiography was performed in 6 cases of thoracic aortic aneurysm. Oblique saturation pulses were used to suppress the signals of the pulmonary artery and SVC, providing excellent selective MR aortograms. Three dimensional extension of the aneurysm and its relation with cervical branches were easily assessed. It could be possible to replace invasive aortography by this technique. (author)

  8. Comparison of gadofosveset-enhanced three-dimensional magnetic resonance angiography with digital subtraction angiography for lower-extremity peripheral arterial occlusive disease

    International Nuclear Information System (INIS)

    Grijalba, Fermin Urtasun; Esandi, Mercedes Ciriza

    2010-01-01

    Background: Minimally invasive imaging techniques are increasingly used for clinical decision making in patients with peripheral arterial occlusive disease (PAOD). Purpose: To assess whether gadofosveset-enhanced three-dimensional (3D) magnetic resonance (MR) angiography could replace digital subtraction angiography (DSA) for the evaluation of lower-extremity PAOD. Material and Methods: Thirty patients with symptomatic PAOD underwent prospectively both MR angiography and DSA. Gadofosveset-enhanced 3D MR angiography was performed on a 1.5T system equipped with a peripheral angio matrix coil. Four blinded observers independently analyzed MR angiograms and DSA images. The lower arterial vascular system was divided into three anatomic segments (aortoiliac, femoropopliteal, infrapopliteal) for review. The status of each segment was graded as normal, stenosis less than 50%, stenosis greater than 50%, or occluded and/or aneurismatic. Principal and secondary lesions were reported. Results: Although interobserver agreement for both was excellent, it was higher for DSA (?=0.92) than for MR angiography (?=0.86) for reporting the principal and secondary lesions in all segments. For different anatomic locations, the interobserver agreement of MR angiography and DSA was as follows: aortoiliac (?=0.93, k=0.95), femoropopliteal (?=0.86, k=0.90), and infrapopliteal (?=0.78, k=0.85). The lowest agreement was found for MR angiography on infrapopliteal segments (?=0.78). In four (13.3%) cases, MR angiography showed lesions that were not found by DSA. Five (16.6%) aneurysm cases, not observed by DSA, were shown by MR angiography. Conclusion: Gadofosveset-enhanced 3D MR angiography can be proposed for first-line imaging in the management of lower-limb PAOD patients and permits the selective use of DSA as a second-line examination when MR angiography fails or in an endovascular approach

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... further information please consult the ACR Manual on Contrast Media and its references. The risk of serious allergic ... View full size with caption Related Articles and Media Angioplasty and Vascular Stenting MR Angiography (MRA) Contrast Materials CT Angiography (CTA) X-ray, Interventional Radiology ...

  10. Microembolism after cerebral angiography

    International Nuclear Information System (INIS)

    Manaka, Hiroshi; Sakai, Hideki; Nagata, Izumi

    2000-01-01

    Acute microemboli are detected more precisely with the recently developed diffusion-weighted MR imaging (DWI). We happened to obtain 24 DWIs after 350 diagnostic cerebral angiographies in 1999. DWIs after cerebral angiographies showed bright lesions in 7 patients (28%), of whom 6 had no neurological symptoms after cerebral angiography. Seven of the 24 patients had risk factors for arteriosclerosis. Only one patient had embolic events due to angiography. Microemboli related to cerebral angiographies are inevitable in some patients. Most are silent, however, we should investigate the cause of microemboli and should make cerebral angiography safer. (author)

  11. Carotid Artery Stenosis: Comparison of 3D Time-of-Flight MR Angiography and Contrast-Enhanced MR Angiography at 3T

    Directory of Open Access Journals (Sweden)

    Ivan Platzek

    2014-01-01

    Full Text Available Purpose. The aim of this study was to assess the correlation of 3D time-of-flight MR angiography (TOF MRA and contrast-enhanced MR angiography (CEMRA for carotid artery stenosis evaluation at 3T. Material and Methods. Twenty-three patients (5 f, 18 m; mean age 61 y, age range 45–78 y with internal carotid artery stenosis detected with ultrasonography were examined on a 3.0T MR system. The MR examination included both 3D TOF MRA and CEMRA of the carotid arteries. MR images were evaluated independently by two board-certified radiologists. Stenosis evaluation was based on a five-point scale. Stenosis grades determined by TOF and CEMRA were compared using Spearman’s rank correlation coefficient and the Wilcoxon test. Cohen’s Kappa was used to evaluate interrater reliability. Results. CEMRA detected stenosis in 24 (52% of 46 carotids evaluated, while TOF detected stenosis in 27 (59% of 46 carotids. TOF MRA yielded significantly higher results for stenosis grade in comparison to CEMRA (P=0.014. Interrater agreement was very good for both TOF MRA (κ=0.93 and CEMRA (κ=0.93. Conclusion. At 3T, 3D TOF MRA should not be used as replacement for contrast-enhanced MRA of the carotid arteries, as it results in significantly higher stenosis grades.

  12. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Rajaram, Smitha [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Academic Unit of Radiology, C Floor, Royal Hallamshire Hospital, Sheffield (United Kingdom); Swift, Andrew J.; Wild, Jim M. [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Capener, David; Telfer, Adam [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Davies, Christine; Hill, Catherine [Sheffield Teaching Hospitals Trust, Department of Radiology, Sheffield (United Kingdom); Condliffe, Robin; Elliot, Charles; Kiely, David G. [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Hurdman, Judith [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom)

    2012-02-15

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  13. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Rajaram, Smitha; Swift, Andrew J.; Wild, Jim M.; Capener, David; Telfer, Adam; Davies, Christine; Hill, Catherine; Condliffe, Robin; Elliot, Charles; Kiely, David G.; Hurdman, Judith

    2012-01-01

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  14. Symptomatic middle cerebral artery stenosis and occlusion. Comparison of three-dimensional time-of-flight magnetic resonance angiography with conventional angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, Motoshi; Yano, Hirohito; Shinoda, Jun; Funakoshi, Takashi [Daiyukai General Hospital, Ichinomiya, Aichi (Japan); Kumagai, Morio

    1994-10-01

    The usefulness of magnetic resonance (MR) angiography using the three-dimensional time-of-flight method for the characterization of symptomatic middle cerebral artery (MCA) occlusive lesions was evaluated in 10 patients with MCA occlusion and 10 with MCA stenosis. All lesions were symptomatic and documented by conventional angiography. There was no false-negative MR angiogram that failed to demonstrate the MCA occlusive lesion. MR angiography correctly evaluated the location of lesions and the difference between stenosis and occlusion. Stenosis appeared as a focal signal loss (<1.0cm) of the MCA at the site of stenosis, and occlusion as a complete signal loss of the MCA distal to the site of occlusion. However, MR angiography could not distinguish diffuse stenosis and one point stenosis demonstrated by conventional angiography. MR angiography is a useful noninvasive diagnostic method for evaluating occlusive lesions of the MCA in symptomatic patients. (author).

  15. Extremely long posterior communicating artery diagnosed by MR angiography: report of two cases.

    Science.gov (United States)

    Uchino, Akira; Suzuki, Chihiro; Tanaka, Masahiko

    2015-07-01

    We report two cases of an extremely long left posterior communicating artery (PCoA) diagnosed by magnetic resonance (MR) angiography. The PCoA arose from the normal point of the supraclinoid internal carotid artery and fused with the posterior cerebral artery (PCA) at its posterior ambient segment, forming an extremely long PCoA and extremely long precommunicating segment of the PCA. To our knowledge, this is the first report of such variation. Careful observation of MR angiographic images is important for detecting rare arterial variations. To identify these anomalous arteries on MR angiography, partial maximum-intensity-projection images are useful.

  16. Magnetic resonance angiography of arteriovenous malformation in the brainstem

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Hirofumi; Kida, Yoshihisa; Kobayashi, Tatsuya; Tanaka, Takayuki; Iwakoshi, Takayasu; Kai, Osamu; Hirose, Mitsuhiko [Komaki City Hospital, Aichi (Japan)

    1993-11-01

    The magnetic resonance (MR) angiography appearance of arteriovenous malformation (AVM) in the tegmentum and pons is described. The interpeduncular perforating branches of the posterior cerebral artery and median pontine branches of the basilar artery were seen more clearly by MR angiography than by conventional angiography. MR angiography was very useful for the follow-up of AVM after stereotactic radiosurgery. (author).

  17. Dynamic contrast-enhanced subtraction MR angiography in intracranial vascular abnormalities

    International Nuclear Information System (INIS)

    Takano, K.; Ono, H.; Utsunomiya, H.; Okazaki, M.; Tanaka, A.

    1999-01-01

    We present our clinical experience with dynamic contrast-enhanced MR angiography (MRA) with subtraction for assessing intracranial vascular abnormalities. Ten patients with various cerebrovascular disorders underwent dynamic contrast-enhanced MRA on a 1.0-T system. Thirty sections (2 mm) were acquired in 29-30 s. Maximum intensity projection images and subtracted source images were compared with those obtained by conventional angiography. In all cases, the presence or absence of abnormalities in the targeted vessels, as well as the morphology of the sagittal sinuses, was clearly visualized as in conventional angiography, without any obstructions such as hyperintense hematomas or thrombi, or intraluminal turbulence. Although the temporal and spatial resolutions with current hardware are insufficient, these preliminary results suggest that dynamic contrast-enhanced MRA with subtraction may be useful for assessing vascular lesions with hemorrhage or thrombus, and the dural sinuses. (orig.)

  18. Craniofacial duplication (diprosopus): CT, MR imaging, and MR angiography findings case report.

    Science.gov (United States)

    Hähnel, Stefan; Schramm, Peter; Hassfeld, Stefan; Steiner, Hans H; Seitz, Angelika

    2003-01-01

    Diprosopus is one of the rarest malformations in humans. In addition to the facial structures, the cerebral frontal lobes were duplicated in this case. Three pairs of anterior cerebral arteries were detected, and the rostral parts of the superior sagittal sinus were duplicated. Computed tomography, magnetic resonance (MR) imaging, and MR angiography allowed study of the degree of duplicative changes in diprosopus, especially for planning cosmetic correction. Copyright RSNA, 2002

  19. Pediatric CT angiography

    International Nuclear Information System (INIS)

    Siegel, M.J.

    2005-01-01

    Advances in CT technology are having profound impact on imaging children and have made CT angiography possible even in neonates. Even with the tiny anatomy of neonates, small volumes of contrast material, and small venous access catheters, successful CT angiography can be performed with attention to detail. Meticulous attention to patient preparation, the proper selection of technical factors, and optimal delivery of contrast material are crucial. Data post-processing and the creation of 3-D reconstructions are also essential in establishing a correct diagnosis. The applications fo CT angiography are different in children than in adults and most applications in children involve assessment of congenital and postoperative vascular and cardiac diseases. The use of CT angiography offers the opportunity to eliminate the long periods of sedation associated with MR and reduce the radiation exposure associated with conventional angiography. Generally, the benefits of CT angiography in children outweigh the risk, namely that of radiation exposure. However, care must still be taken to minimize the radiation exposure. (orig.)

  20. Striatocapsular infarction: MRI and MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Croisille, P. (Dept. of Neuroradiology, Hopital Neurologique et Neurochirurgical Pierre Wertheimer, Lyon (France)); Turjman, F. (Dept. of Neuroradiology, Hopital Neurologique et Neurochirurgical Pierre Wertheimer, Lyon (France)); Croisile, B. (Dept. of Neurology, Hopital Neurologique et Neurochirurgical Pierre Wertheimer, Lyon (France)); Tournut, P. (Dept. of Neuroradiology, Hopital Neurologique et Neurochirurgical Pierre Wertheimer, Lyon (France)); Laharotte, J.C. (Dept. of Neuroradiology, Hopital Neurologique et Neurochirurgical Pierre Wertheimer, Lyon (France)); Aimard, G. (Dept. of Neurology, Hopital Neurologique et Neurochirurgical Pierre Wertheimer, Lyon (France)); Trillet, M. (Dept. of Neurology, Hopital Neurologique et Neurochirurgical Pierre Wertheimer, Lyon (France)); Duquesnel, J. (Dept. of Neuroradiology, Hopital Neurologique et Neurochirurgical Pierre Wertheimer, Lyon (France)); Froment, J.C. (Dept. of Neuroradiology, Hopital Neurologique et Neurochirurgical Pierre

    1994-08-01

    We present a case of left striatocapsular infarction manifest clinically as a transient right hemiparesis. MRI showed a left striatocapsular infarct. Striatocapsular infarction, unlike lacunar infarction, is often associated with occlusive disease of the carotid artery. In order to screen the carotid vessels, cervical MR angiography (MRA) was performed during the same examination, demonstrating a left internal carotid artery occlusion, confirmed by contrast arteriography. MRA, a noninvasive modality, can be a useful adjunct to MRI, when diagnostic information concerning the cervical carotid artery is needed. (orig.)

  1. Non-contrast MR angiography for diagnosis of congenital heart disease

    International Nuclear Information System (INIS)

    Matsuo, Mikaru; Yoshioka, Kunihiro; Takahashi, Shin; Oyama, Kotaro

    2006-01-01

    Fast imaging employing steady state acquisition (FIESTA) has been reported to be suitable for cardiac imaging in adolescents and adults. The purpose of this study was to establish the applicability and limitation of MR Angiography using FIESTA in the diagnosis of congenital heart disease. Thirty-five patients with congenital heart disease underwent MR Angiography using FIESTA and the 3D Gd-enhanced fast spoiled gradient recalled acquisition in the steady state (SPGR) technique. The measurements of the vascular diameters and diagnostic quality of the two techniques were compared. Correlations between FIESTA and the 3D Gd-fast SPGR technique were excellent in vascular diameter (aAo 0.90, arch 0.78, dAo 0.92, SCA 0.70, RPA 0.90, LPA 0.95). The agreement of the vascular diameters in the Bland-Altman method was good (aAo 0.22 mm, arch 0.07 mm, dAo 0.14 mm, SCA 0.31 mm, RPA 0.45 mm, LPA 0.12 mm). However, MR angiography (MRA) by 3D Gd-enhanced SPGR had a higher resolution than that by FIESTA. Due to signal loss caused at the regions of vascular stenosis or Blalock-Taussig shunt on FIESTA, we could not evaluate the vascular diameter or patency at those lesions. FIESTA is a useful technique of non-enhanced MRA for non-invasive diagnosis of congenital heart disease. However, MRA by FIESTA was not adequate for multiplanar reconstruction. (author)

  2. MR-Guided PTA in Experimental Bilateral Rabbit Renal Artery Stenosis and MR Angiography Follow-Up Versus Histomorphometry

    International Nuclear Information System (INIS)

    Le Blanche, Alain-Ferdinand; Rossert, Jerome; Wassef, Michel; Levy, Bernard; Bigot, Jean-Michel; Boudghene, Frank

    2000-01-01

    Purpose: To assess in vivo 1) MR-guided percutaneous transluminal renal angioplasty (PTRA) in experimental bilateral rabbit renal artery stenosis (RAS); 2) postprocedural follow-up by gadolinium-enhanced MR angiography versus histomorphometry.Methods: Fifteen male NZW rabbits of mean weight 4.0 kg (range 3.5-4.2 kg) underwent bilateral RAS induction by combined overdilation-deendothelialization with a gadolinium-filled balloon, passively MR-guided by the artifact of a 0.014-inch guidewire. After 4 weeks the rabbits were randomized into two groups: group A (n = 8) underwent right-sided PTRA for treatment of RAS, group B (n = 7) underwent left-sided PTRA. After another 4 weeks the rabbits were killed to assess by histomorphometry recurrent stenosis and contralateral induction injury stenosis lesions. Each step was preceded by gadolinium-enhanced three-dimensional MR angiography, and the cortex-to-aorta (C/A) signal intensity ratio was calculated.Results: RAS induction was successful in all cases. Fourteen arteries developed restenosis and 13 only initial stenosis. MR-guided PTRAs were feasible in 22 arteries (73%). For a successful catheterization of the ostium (20 arteries, 66% success rate), 10-25 steps were required. Five to eight steps were required for balloon localization and inflation for each PTRA. The restenosis effect was reflected by a 16% (12%-27%) decrease in C/A values on MR angiograms (p < 0.05).Conclusion: MR guidance and MR angiography represent a feasible, less invasive alternative for performing and assessing experimental PTRA in RAS

  3. Ischemic lesions related to cerebral angiography: Evaluation by diffusion weighted MR imaging

    International Nuclear Information System (INIS)

    Kato, Koki; Tomura, Noriaki; Takahashi, Satoshi; Sakuma, Ikuo; Watarai, Jiro

    2003-01-01

    We examined the incidence of ischemic lesions occurring after cerebral angiography by means of diffusion weighted MR imaging (DWI). Fifty patients were included in this study. Balloon occlusion tests of the internal carotid artery were performed in 9 of the 50 patients. DWI was performed on the same day as the cerebral angiography or on the following day. No new neurological deficits were found after cerebral angiography. However, 13 of the 50 cases revealed new ischemic lesions after cerebral angiography. The incidence of ischemic lesions was significantly different between patients who underwent balloon occlusion tests and patients who did not. The incidence of ischemic lesions was not influenced by the duration of the procedure, use of additional catheters, total amount of contrast material or the type of contrast material. The incidence of clinically silent ischemic lesions related to cerebral angiography is greater than the incidence of neurological complications. In patients who underwent occlusion tests of the internal carotid artery, the incidence of silent lesions was significantly higher than in patients who did not. (orig.)

  4. An investigation of cerebral magnetic resonance angiography, 4

    International Nuclear Information System (INIS)

    Takeda, Sadanori; Sadamoto, Kazuhiko; Ohue, Shiro; Todo, Hirooki; Sakaki, Saburo.

    1991-01-01

    We have been studying MR angiography using the 0.5 tesla system. Recently we developed three-dimensional MR angiography on the 0.5 tesla system using the gradient-echo technique. The purpose of this study is to evaluate the clinical ability of this newly developed 3-D MR angiography to detect intracranial vascular diseases in comparison with SE or 2-D MR angiography. Twenty-eight patients (15 cerebral aneurysms, 8 arteriovenous malformations, and 5 others) were examined. Three-dimensional MR angiography was performed with TRs of from 60 to 90 msec, TEs of from 16 to 22 msec, flip angls of from 15 to 45 degrees, and a 256x256x16 or 32 matrix. The imaging volumes ranged in thickness from 48 to 64 mm. In our study, a subtraction technique composed of rephased and dephased sequences was applied. As the result of utilizing 0.5 tesla 3-D MR angiography with optimal parameters, good visualization of main cerebral arteries such as second-order branches was obtained. Cerebral aneurysms, AVMs, and arterial occlusions were also well demonstrated, but some of the giant aneurysms were displayed insufficiently for the various flows to be determined. We concluded that 3-D MR angiography on the 0.5 tesla system has the ability to detect intracranial vascular lesions and should be the method for the screening and follow-up of intracranial vascular diseases. (author)

  5. Technique for arterial-phase contrast-enhanced three-dimensional MR angiography of the carotid and vertebral arteries.

    Science.gov (United States)

    Isoda, H; Takehara, Y; Isogai, S; Takeda, H; Kaneko, M; Nozaki, A; Sun, Y; Foo, T K

    1998-08-01

    Our goal was to evaluate whether contrast-enhanced three-dimensional MR angiography using the MR Smartprep technique would enable us to obtain arterial-phase MR angiograms of the carotid and vertebral arteries. The study included 35 patients with suspected lesions of the neck in whom the MR Smartprep technique was used for MR angiography performed with a 1.5-T superconducting system. The tracker volume was placed primarily in the middle part of the right common carotid artery. The imaging volume was placed in a coronal direction to include the carotid and vertebral arteries from the aortic arch to the skull base. A centric phase-ordering scheme was used. Imaging times were 20 to 38 seconds for 14 patients and 11 to 16 seconds for 21 patients. By using a smaller tracker volume and an imaging time of less than 16 seconds, we were able to achieve a 100% successful triggering rate and to delineate selectively arterial-phase carotid and vertebral arteries with almost no venous contamination. Contract-enhanced 3-D MR angiography with the MR Smartprep technique was useful for showing arterial-phase carotid and vertebral arteries selectively.

  6. The value of applying nitroglycerin in 3D coronary MR angiography with real-time navigation technique

    International Nuclear Information System (INIS)

    Hackenbroch, M.; Meyer, C.; Schmiedel, A.; Hofer, U.; Flacke, S.; Kovacs, A.; Schild, H.; Sommer, T.; Tiemann, K.; Skowasch, D.

    2004-01-01

    Purpose: Nitroglycerin administration results in dilation of epicardial coronary vessels and in an increase in coronary blood flow, and has been suggested to improve MR coronary angiography. This study evaluates systematically whether administration of nitroglycerin improves the visualization of coronary arteries and, as a result, the detection of coronary artery stenosis during free breathing 3D coronary MR angiography. Materials and Methods: Coronary MR angiography was performed in 44 patients with suspected coronary artery disease at a 1.5 Tesla System (Intera, Philips Medical Systems) (a) with and (b) without continuous administration of intravenous nitroglycerin at a dose rate of 2.5 mg/h, using an ECG gated gradient echo sequence with real-time navigator correction (turbo field echo, in-plane resolution 0.70 x 0.79 mm 2 , acquisition window 80 ms). Equivalent segments of the coronary arteries in the sequences with and without nitroglycerin were evaluated for visualized vessel length and diameter, qualitative assessment of visualization using a four point grading scale and detection of stenoses >50%. Catheter coronary angiography was used as a gold-standard. Results: No significant differences were found between scans with and without nitroglycerin as to average length of the contiguously visualized vessel length (p>0.05) and diameter (p>0.05). There was also no significant difference in the coronary MR angiography with and without nitroglycerin in the average qualitative assessment score of the visualization of LM, proximal LAD, proximal CX, and proximal and distal RCA (2.1±0.8 and 2.2±0.7; p> 0.05). Sensitivity (77% [17/22] vs. 82% [18/22] p>0.05) and specificity (72% [13/18] vs. 72% [13/18] p>0.05) for the detection of coronary artery stenosis also did not differ significantly between scans with and without intravenous administration of nitroglycerin. Conclusion: Administration of nitroglycerin does not improve visualization of the coronary arteries and

  7. 3D-shaded surface rendering of gadolinium-enhanced MR angiography in congenital heart disease

    International Nuclear Information System (INIS)

    Okuda, S.; Kikinis, R.; Dumanli, H.; Geva, T.; Powell, A.J.; Chung, T.

    2000-01-01

    Background. Gadolinium-enhanced three-dimensional (3D) MR angiography is a useful imaging technique for patients with congenital heart disease. Objective. This study sought to determine the added value of creating 3D shaded surface displays compared to standard maximal intensity projection (MIP) and multiplanar reformatting (MPR) techniques when analyzing 3D MR angiography data. Materials and methods. Seventeen patients (range, 3 months to 51 years old) with a variety of congenital cardiovascular defects underwent gadolinium-enhanced 3D MR angiography of the thorax. Color-coded 3D shaded surface models were rendered from the image data using manual segmentation and computer-based algorithms. Models could be rotated, translocated, or zoomed interactively by the viewer. Information available from the 3D models was compared to analysis based on viewing standard MIP/MPR displays. Results. Median postprocessing time for the 3D models was 6 h (range, 3-25 h) compared to approximately 20 min for MIP/MPR viewing. No additional diagnostic information was gained from 3D model analysis. All major findings with MIP/MPR postprocessing were also apparent on the 3D models. Qualitatively, the 3D models were more easily interpreted and enabled adjacent vessels to be distinguished more readily. Conclusion. Routine use of 3D shaded surface reconstructions for visualization of contrast enhanced MR angiography in congenital heart disease cannot be recommended. 3D surface rendering may be more useful for presenting complex anatomy to an audience unfamiliar with congenital heart disease and as an educational tool. (orig.)

  8. Hemodynamics of ovarian veins: MR angiography in women with uterine leiomyomata

    International Nuclear Information System (INIS)

    Kin, Yoko; Katsumori, Tetsuya; Kasahara, Toshiyuki; Nozaki, Taiki; Ito, Hirotoshi; Nishimura, Tsunehiko

    2007-01-01

    Purpose: The passive reflux into ovarian veins (OVs) is well known as a common finding in normal asymptomatic women. The purpose of this study was to investigate the hemodynamics of OVs in women with myomatous uterus. Materials and methods: Thirty-two women with symptomatic uterine leiomyomata underwent time-of-flight MR (TOF-MR) angiography, including venography and arteriography, and contrast-enhanced MRI. The frequency of reflux into OVs on TOF-MR angiography was retrospectively assessed with uterine volume, and compared to that of normal women in previous publication. The statistical evaluation was performed using Fisher's exact test. Results: The mean uterine volume was 932 ± 612 ml (range, 301-2627 ml). The reflux into left OVs was observed in 4 of 32 women (13%) and that into right OVs was noted in 0 of 32 women (0%). These rates were significantly lower than those of normal asyptomatic women in the previous publication (p < 0.05). The reflux into OVs was observed in 0 of 19 women (0%) with 600 ml or larger myomatous uterus, whereas it was noted in 4 of the remaining 13 women (31%) with less than 600 ml myomatous uterus, with significant difference between the two groups (p = 0.02). Conclusions: We found that reflux into OVs was infrequent in the vast majority of women with myomatous uterus, especially those with larger uterus due to leiomyomata on the basis of TOF-MR angiography. These findings suggested myomatous uterus could affect the flow direction of OVs, and passive reflux into OVs might be prevented due to the influence of antegrade flow of OVs

  9. MR coronary angiography with breath-hold targeted volumes: preliminary clinical results

    NARCIS (Netherlands)

    R.J.M. van Geuns (Robert Jan); P.A. Wielopolski (Piotr); H.G. de Bruin (Hein); B.J.W.M. Rensing (Benno); M. Hulshoff (Maarten); P.M.A. van Ooijen (Peter); P.J. de Feyter (Pim); M. Oudkerk (Matthijs)

    2000-01-01

    textabstractPURPOSE: To assess the clinical value of a magnetic resonance (MR) coronary angiography strategy involving a small targeted volume to image one coronary segment in a single breath hold for the detection of greater than 50% stenosis. MATERIALS AND METHODS:

  10. Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography.

    Science.gov (United States)

    Zhang, Tao; Yousaf, Ufra; Hsiao, Albert; Cheng, Joseph Y; Alley, Marcus T; Lustig, Michael; Pauly, John M; Vasanawala, Shreyas S

    2015-10-01

    Pediatric contrast-enhanced MR angiography is often limited by respiration, other patient motion and compromised spatiotemporal resolution. To determine the reliability of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography method for depicting abdominal arterial anatomy in young children. With IRB approval and informed consent, we retrospectively identified 27 consecutive children (16 males and 11 females; mean age: 3.8 years, range: 14 days to 8.4 years) referred for contrast-enhanced MR angiography at our institution, who had undergone free-breathing spatiotemporally accelerated time-resolved contrast-enhanced MR angiography studies. A radio-frequency-spoiled gradient echo sequence with Cartesian variable density k-space sampling and radial view ordering, intrinsic motion navigation and intermittent fat suppression was developed. Images were reconstructed with soft-gated parallel imaging locally low-rank method to achieve both motion correction and high spatiotemporal resolution. Quality of delineation of 13 abdominal arteries in the reconstructed images was assessed independently by two radiologists on a five-point scale. Ninety-five percent confidence intervals of the proportion of diagnostically adequate cases were calculated. Interobserver agreements were also analyzed. Eleven out of 13 arteries achieved acceptable image quality (mean score range: 3.9-5.0) for both readers. Fair to substantial interobserver agreement was reached on nine arteries. Free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography frequently yields diagnostic image quality for most abdominal arteries in young children.

  11. Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Tao; Cheng, Joseph Y. [Stanford University, Department of Radiology, Stanford, CA (United States); Stanford University, Department of Electrical Engineering, Stanford, CA (United States); Yousaf, Ufra; Alley, Marcus T.; Vasanawala, Shreyas S. [Stanford University, Department of Radiology, Stanford, CA (United States); Hsiao, Albert [University of California, San Diego, Department of Radiology, San Diego, CA (United States); Lustig, Michael [Stanford University, Department of Electrical Engineering, Stanford, CA (United States); University of California, Berkeley, Department of Electrical Engineering and Computer Sciences, Berkeley, CA (United States); Pauly, John M. [Stanford University, Department of Electrical Engineering, Stanford, CA (United States)

    2015-10-15

    Pediatric contrast-enhanced MR angiography is often limited by respiration, other patient motion and compromised spatiotemporal resolution. To determine the reliability of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography method for depicting abdominal arterial anatomy in young children. With IRB approval and informed consent, we retrospectively identified 27 consecutive children (16 males and 11 females; mean age: 3.8 years, range: 14 days to 8.4 years) referred for contrast-enhanced MR angiography at our institution, who had undergone free-breathing spatiotemporally accelerated time-resolved contrast-enhanced MR angiography studies. A radio-frequency-spoiled gradient echo sequence with Cartesian variable density k-space sampling and radial view ordering, intrinsic motion navigation and intermittent fat suppression was developed. Images were reconstructed with soft-gated parallel imaging locally low-rank method to achieve both motion correction and high spatiotemporal resolution. Quality of delineation of 13 abdominal arteries in the reconstructed images was assessed independently by two radiologists on a five-point scale. Ninety-five percent confidence intervals of the proportion of diagnostically adequate cases were calculated. Interobserver agreements were also analyzed. Eleven out of 13 arteries achieved acceptable image quality (mean score range: 3.9-5.0) for both readers. Fair to substantial interobserver agreement was reached on nine arteries. Free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography frequently yields diagnostic image quality for most abdominal arteries in young children. (orig.)

  12. Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography

    International Nuclear Information System (INIS)

    Zhang, Tao; Cheng, Joseph Y.; Yousaf, Ufra; Alley, Marcus T.; Vasanawala, Shreyas S.; Hsiao, Albert; Lustig, Michael; Pauly, John M.

    2015-01-01

    Pediatric contrast-enhanced MR angiography is often limited by respiration, other patient motion and compromised spatiotemporal resolution. To determine the reliability of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography method for depicting abdominal arterial anatomy in young children. With IRB approval and informed consent, we retrospectively identified 27 consecutive children (16 males and 11 females; mean age: 3.8 years, range: 14 days to 8.4 years) referred for contrast-enhanced MR angiography at our institution, who had undergone free-breathing spatiotemporally accelerated time-resolved contrast-enhanced MR angiography studies. A radio-frequency-spoiled gradient echo sequence with Cartesian variable density k-space sampling and radial view ordering, intrinsic motion navigation and intermittent fat suppression was developed. Images were reconstructed with soft-gated parallel imaging locally low-rank method to achieve both motion correction and high spatiotemporal resolution. Quality of delineation of 13 abdominal arteries in the reconstructed images was assessed independently by two radiologists on a five-point scale. Ninety-five percent confidence intervals of the proportion of diagnostically adequate cases were calculated. Interobserver agreements were also analyzed. Eleven out of 13 arteries achieved acceptable image quality (mean score range: 3.9-5.0) for both readers. Fair to substantial interobserver agreement was reached on nine arteries. Free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography frequently yields diagnostic image quality for most abdominal arteries in young children. (orig.)

  13. Inflammatory aortic arch syndrome: contrast-enhanced, three-dimensional MR - angiography in stenotic lesions

    International Nuclear Information System (INIS)

    Both, M.; Mueller-Huelsbeck, S.; Biederer, J.; Heller, M.; Reuter, M.

    2004-01-01

    Purpose: To determine the value of contrast-enhanced, three-dimensional MR angiography for the evaluation of stenotic and occlusive vascular lesions in inflammatory aortic arch syndrome. Materials and Methods: 14 patients with inflammatory aortic arch syndrome (giant cell arteritis: n = 8, Takayasu arteritis: n = 4, ankylosing spondylitis: n = 1 sarcoidosis: n = 1) underwent MR angiography of the aortic arch and the supra-aortic vessels (n = 15,2 patients were examined twice) and of the abdominal aorta (n = 2). MRA was performed using a 3D-FLASH sequence (TR/TE 4.6/1.8 ms, flip angle 30 ) on a 1.5T system. MRA imaging was compared with the findings of DSA, which served as gold standard. Results: In a total of 467 examined vascular territories, DSA revealed 50 stenoses and 35 occlusions. All lesions were detected by MRA. In 23 segments, the degree of stenosis was overestimated by MRA. Sensitivity and specificity of MRA were 100% and 94,3%, positive and negative predictive values were 73.6 and 100%, and the accuracy was 95,1%. Conclusions: Despite a tendency to overestimate stenoses, contrast-enhanced three-dimensional MR angiography is a valid, non-invasive technique in the assessment of inflammatory aortic arch syndrome. (orig.) [de

  14. Three-dimensional MR angiography of the intracranial circulation in neonates following extracorporeal membrane oxygenation

    International Nuclear Information System (INIS)

    Lewin, J.S.; Masaryk, T.J.; Wiznitzer, M.; Ross, J.S.; Modic, M.T.; Stork, E.K.; Bryan, P.J.; Butler, H.

    1988-01-01

    Extracorporeal membrane oxygenation (ECMO) is a neonatal systemic oxygenation technique that involves cannulation and subsequent ligation of the right internal jugular vein and common carotid artery. The purpose of this study was to implement a comprehensive neurovascular evaluation in these patients by means of a new three-dimensional MR angiography technique that used reduced echo time and voxel size, gradient refocusing, and time-of-flight effects to maximize vascular contrast. A standard T2-weighted multiecho MR imaging study was also performed. The patient population consisted of 12 infants who had undergone ECMO. Vascular examinations of diagnostic quality were performed in 80% of patients. The findings indicate that MR angiography is a reliable method for evaluation of the intracranial circulation in patients following ECMO therapy

  15. Retrograde flow in the dural sinuses detected by three-dimensional time-of-flight MR angiography

    International Nuclear Information System (INIS)

    Uchino, Akira; Nomiyama, Keita; Takase, Yukinori; Nakazono, Takahiko; Tominaga, Yukiko; Imaizumi, Takeshi; Kudo, Sho

    2007-01-01

    Retrograde flow in the left dural sinuses is sometimes detected by three-dimensional time-of-flight (3D-TOF) magnetic resonance (MR) angiography. The purpose of this study was to evaluate the incidence of this phenomenon and its characteristic features on 3D-TOF MR angiograms. We retrospectively reviewed cranial MR angiography images of 1,078 patients examined at our institution. All images were obtained by the 3D-TOF technique with one of two 1.5-T scanners. Maximum intensity projection (MIP) images in the horizontal rotation view were displayed stereoscopically. We reviewed the source images, inferosuperior MIP images, and horizontal MIP images and identified retrograde flow in the dural sinuses. We found retrograde flow in the dural sinuses of 67 patients on the source images from 3D-TOF MR angiography; the incidence was 6.2%. In 47 of the 67 patients, retrograde flow was identified in the left inferior petrosal sinus, in 13, it was seen in the left sigmoid sinus, and in 6, it was seen in the left inferior petrosal and left sigmoid sinuses. The remaining patient had retrograde flow in the left inferior petrosal and left and right sigmoid sinuses. The mean age of the patients with retrograde flow was slightly greater than that of the patients without this phenomenon (70 years vs 63 years). Retrograde flow in the dural sinuses frequently occurs on the left side in middle-aged and elderly patients during 3D-TOF MR angiography performed with the patient in the supine position. This phenomenon should not be misdiagnosed as a dural arteriovenous fistula. (orig.)

  16. Preoperative evaluation of neurovascular relationship by using contrast-enhanced and unenhanced 3D time-of-flight MR angiography in patients with trigeminal neuralgia

    International Nuclear Information System (INIS)

    Qin, Zhou; Zhiling, Liu; Chuanfu, Li; Qingshi Zeng; Chuncheng, Qu; Shilei, Ni

    2011-01-01

    Background Microvascular decompression is an etiological strategy for the therapy of trigeminal neuralgia (TN). Preoperative identification of neurovascular compression, therefore, could have an impact on the determination of appropriate treatment for TN. Purpose To evaluate the value of contrast-enhanced and unenhanced three-dimensional (3D) time-of-flight (TOF) MR angiography in the visualization of neurovascular relationship in patients with TN. Material and Methods Thirty-seven patients with unilateral TN underwent unenhanced and contrast-enhanced 3D TOF MR angiography with a 3.0-T MR system. Images were reviewed by a radiologist blinded to clinical details. Vascular contact with the trigeminal nerve was identified, and the nature of the involved vessels (artery or vein) was determined. All patients underwent microvascular decompression. Results In 37 patients with TN, contrast-enhanced 3D TOF MR angiography identified surgically verified neurovascular contact in 35 of 36 symptomatic nerves, and there was no false-positive. Based on surgical findings, the sensitivity of MR imaging was 97.2% and specificity 100%. The nature of the offending vessel was correctly identified in 94.4% of the patients by using the combination of contrast-enhanced and unenhanced MR angiography. Conclusion Contrast-enhanced 3D TOF MR angiography is useful in the detection of vascular contact with the trigeminal nerve in patients with TN, and this MR imaging in combination with unenhanced MR angiography could help in the identification of the nature of the responsible vessels

  17. MR coronary angiography with breath-hold targeted volumes : Preliminary clinical results

    NARCIS (Netherlands)

    van Geuns, R J; Wielopolski, P A; de Bruin, Hein G.; Rensing, B J; Hulshoff, Marc; van Ooijen, P M; de Feyter, P J; Oudkerk, M

    2000-01-01

    PURPOSE: To assess the clinical value of a magnetic resonance (MR) coronary angiography strategy involving a small targeted volume to image one coronary segment in a single breath hold for the detection of greater than 50% stenosis. MATERIALS AND METHODS: Thirty-eight patients referred for elective

  18. High-resolution coronary MR angiography for evaluation of patients with anomalous coronary arteries: visualization of the intramural segment

    Energy Technology Data Exchange (ETDEWEB)

    Biko, David M. [UCSF Benioff Children' s Hospital Oakland, Department of Diagnostic Imaging, Oakland, CA (United States); The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Chung, Claudia; Chung, Taylor [UCSF Benioff Children' s Hospital Oakland, Department of Diagnostic Imaging, Oakland, CA (United States); Hitt, David M. [Philips Healthcare, Cleveland, OH (United States); Kurio, Gregory [UCSF Benioff Children' s Hospital Oakland, Department of Cardiology, Oakland, CA (United States); Reinhartz, Olaf [UCSF Benioff Children' s Hospital Oakland, Department of Cardiac Surgery, Oakland, CA (United States)

    2015-08-15

    Anomalous origin of the coronary artery from the contralateral coronary sinus is a rare coronary anomaly associated with sudden death. The inter-arterial course is most closely associated with sudden death, but it has been suggested that the presence of an intramural segment of a right anomalous coronary is associated with more symptoms and therefore may be an important criterion for intervention in these patients. To demonstrate that MR angiography can accurately determine the presence or absence of an intramural segment in an anomalous coronary artery. All studies of children who underwent MR angiography for the evaluation of an anomalous coronary artery were retrospectively reviewed by two pediatric radiologists in consensus. Criteria for an intramural anomalous coronary artery were the presence of a small or slit-like ostium and the relative smaller size of the proximal intramural portion of the coronary artery in relation to the more distal epicardial coronary artery. The anomalous coronary artery was classified as not intramural if these two findings were absent. These findings were correlated with operative reports confirming the presence or absence of an intramural segment. Twelve patients (86%) met MR angiography criteria for the presence of an intramural course. Only 2 patients (14%) met MR angiography criteria for a non-intramural course. When correlating with intraoperative findings, MR angiography was successful in distinguishing between intramural and non-intramural anomalous coronary arteries in all cases (P = 0.01). MR angiography may be able to reliably identify the intramural segment of an anomalous coronary artery in older children using the imaging criteria of a small or slit-like ostium and relative decrease in size of the proximal portion of the anomalous coronary artery compared to the distal portion of the anomalous coronary artery. Determining the presence of the intramural segment may help with surgical planning and may be an important

  19. Evaluation of intracranial arteriovenous malformations before and after embolization with dynamic MR digital subtraction angiography

    International Nuclear Information System (INIS)

    Chen Shuang; Feng Xiaoyuan; Baleriaux, D.; Metens, T.

    2005-01-01

    Objective: To evaluate the clinical utility and accuracy of dynamic MR digital subtraction angiography (MR-DSA) in the detection of intracranial arteriovenous malformations before and after embolization. Methods: A prospective blinded comparison of MR-DSA, 3D contrast-enhanced T 1 -weighted MR angiography (3D-CEMRA), proton-weighted imaging and conventional digital subtraction angiography (DSA) were underwent in 22 consecutive AVMs patients before and after embolization. Two readers independently interpreted images and compared with DSA images. Results: There was complete agreement between MR-DSA and DSA for classification and size of nidus before and after embolization in all cases. MR-DSA showed the modified hemodynamic features (the time of nidus, early venous enhancement delayed after carotid arteries appearance) in 17 cases, and nidus size were reduced in 13 cases (including 4 complete embolized cases) after embolization, which were 100% consistence compared with DSA. MR-DSA failed to depict 1 intranidal aneurysm and missed 1 less dilated artery and draining vein after embolization respectively, which were demonstrated clearly by 3D-CEMRA confirmed with DSA. The relatively more or less hyperintensity could be seen on proton-weighted imaging in all cases after embolization than before. Conclusion: MR-DSA is a fast, efficient, and noninvasive technique to provide hemodynamic information relevant for AVMs before and after embolization. Proton imaging is sensitive in delineation of the embolized region, MR-DSA, 3D-CEMRA and proton-weighted imaging should be combined in the evaluation and follow-up AVMs after partial embolization. (authors)

  20. Enhanced MR angiography of the lower extremities with synergy spine coil

    International Nuclear Information System (INIS)

    Takashima, Hiroyuki; Watanabe, Naoki

    2002-01-01

    A synergy spine coil is a phased-array coil designed for spine imaging. The coil's sensitive area is narrow in both the x-axis and y-axis directions but very wide in the z-axis direction. It is therefore suitable for using in long parts of the body, such as the spine. We used the coil for enhanced MR angiography in the lower extremities, which requires a very long field of view on the z-axis direction. Using on the NEMA (National Electrical Manufacturers Association) standard test for special-purpose coils, the sensitive volume of the synergy spine coil was first measured by using a phantom. It was found that the sensitive lengths along x-axis and y-axis were 300 mm and 120 mm, respectively, while that along z-axis could set at any length required for the examination by modifying the element number. The above area was confirmed to be sufficient for obtaining enhanced MR angiograms of the lower extremities. The results of this study showed the use of the synergy spine coil in enhanced MR angiography of the lower extremities is superior to the use of a conventional whole body coil for obtaining good MR angiograms with a good single-to-noise ratio (SNR). (author)

  1. TOF MR angiography of cerebral arteriovenous malformations before and after radiotherapy

    International Nuclear Information System (INIS)

    Schlemmer, H.P.; Hess, T.; Debus, J.; Knopp, M.V.; Schad, L.R.; Engenhart, R.

    1994-01-01

    We studied whether 3D time-of-flight (TOF) MR angiography can be used for therapy planning and monitoring. MRI and TOF-MRA studies of 28 patients undergoing radiotherapy were evaluated. They were compared to conventional angiography to assess the MRA study. A correct identification of the arterial feeder and the nidus was possible in about 75% of the patients. In combination with the MRI study, an important 3D dataset for treatment planning could be obtained that includes therapeutically relevant information on the localization and spatial structure of the AVM as well as the adjacent brain tissue. As a noninvasive technique, close-meshed follow-up studies could be performed with MRA. (orig./MG) [de

  2. Clinical application of gadolinium-enhanced three-dimensional pulmonary MR angiography

    International Nuclear Information System (INIS)

    Takano, Katsuyuki

    1999-01-01

    Twenty-nine patients with suspected pulmonary lesions, and three normal volunteers, underwent gadolinium-enhanced three-dimensional (3D) pulmonary MR angiography (MRA). The MRA were obtained during intravenous administration of gadolinium-based contrast material, in a single breath-hold. Conspicuity of the normal pulmonary segmental arteries was estimated on the MRA. Abnormal findings such as ''vascular involvement'', ''abnormal connection'', stenosis'', or ''dilatation'' on the MRA were compared with those on conventional angiography or CT. Normal pulmonary segmental arteries, except for A 4,5,6,8and9 of the left pulmonary artery, could be clearly visualized. Blind reading of four different findings lead to characteristic findings for each pulmonary disease that can be aid in their differential diagnoses. This technique shows promise as a noninvasive diagnosis of lung diseases. (author)

  3. Evaluation of three-dimensional contrast-enhanced MR angiography in pediatric body vascular lesions

    International Nuclear Information System (INIS)

    Tanaka, Yasunori; Katayama, Hiroshi; Yamamoto, Kazuhiro; Shimizu, Tadafumi; Narabayashi, Isamu

    1998-01-01

    Evaluation of three-dimensional contrast-enhanced MR angiography in the pediatric body vascular lesions. This study examined the usefulness of three-dimensional gadolinium-enhanced magnetic resonance angiography (3D-enhanced MRA) for pediatric body vascular lesions. Fifteen 3D-enhanced MRAs were performed on fourteen pediatric patients aged from one month to fifteen years, using a 3D fast SPGR sequence. Maximum intensity projection (MIP) and multiplanar reconstruction (MPR) images were obtained from the imaging data in all cases, and eleven MIP images were obtained after subtraction of precontrast-enhanced imaging data from postcontrast-enhanced imaging data. In six cases, MIP and MPR images were correlated with cine or digital subtraction angiographies, and the eleven subtracted MIP images were compared with those before subtraction. Clinical usefulness was demonstrated in fourteen (93%) of the fifteen cases, and in seven (64%) of the eleven cases in which subtraction was performed, image quality was improved. In comparison with cine or digital subtraction angiographies, however, only one (17%) MRA was superior. It was considered that 3D-enhanced MRA was useful for pediatric body vascular lesions because of advantages such as lower invasiveness compared with that of conventional angiography, absence of radiation exposure, safety of contrast media, easy availability of MPR images, and short scanning time. In conclusion, if a pediatric body vascular lesion is suspected, 3D-enhanced MRA should be performed before conventional angiography. It also seems that 3D-enhanced MRA may be useful for follow-up. (author)

  4. Usefulness of MR angiography in cases of central vertigo.

    Science.gov (United States)

    Fujita, Nobuya; Yamanaka, Toshiaki; Hosoi, Hiroshi

    2002-07-01

    Syndromal vertigo is defined as a combination of vestibular function disturbance and cranial nerve or cerebral function disturbance. There is evidence that MR angiography (MRA), providing angiogram-like images of the intracranial and extracranial arterial flow, could replace invasive methods for diagnosing central vertigo. The purpose of this study was to provide simplified MRA criteria for identifying morbidity and to analyze the relation between imaging findings and clinical manifestations. Thirty-three individuals with symptoms of syndromal vertigo and vertebrobasilar territory disease were examined by equilibriometry, MR imaging (MRI) and MRA. Under MRA, vertebral artery (VA) stenosis was more common than VA occlusion (23 vs. nine cases, respectively). A basilar artery (BA) deviation was found in eight cases (24.2%). Twenty-five VA or BA abnormalities (75.8%) were found, and eight combined VA and BA abnormalities (24.2%) were found. We emphasize three points as follows. MRA is advantageous over conventional angiography for less invasive method. MRA can reveal abnormalities even in cases of 'solo-vertigo' with no observed neurologic abnormalities. In our series, abnormalities were confirmed by MRA even in cases with no concomitant such as hypertension, coronary heart disease, or diabetes mellitus, which are regarded as latent risk factors for stroke.

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ... about radiology? Share your patient story here Images × ... Related Articles and Media Angioplasty and Vascular Stenting MR Angiography (MRA) Contrast ...

  6. Diagnostic yield and accuracy of CT angiography, MR angiography, and digital subtraction angiography for detection of macrovascular causes of intracerebral haemorrhage: Prospective, multicentre cohort study

    NARCIS (Netherlands)

    C.J.J. Van Asch (Charlotte J.J.); B.K. Velthuis (Birgitta K.); G.J.E. Rinkel (Gabriël J.E.); A. Algra (Ale); G.A.P. de Kort (G. A P); T.D. Witkamp (Theo); J.C.M. De Ridder (Johanna C.M.); K.M. Van Nieuwenhuizen (Koen M.); F.-E. De Leeuw (Frank-Erik); W.J. Schonewille (Wouter); P.L.M. de Kort (Paul); D.W.J. Dippel (Diederik); T.W.M. Raaymakers (Theodora W.M.); J. Hofmeijer; M.J.H. Wermer (Marieke); H. Kerkhoff (Henk); K. Jellema (Korné); I.M. Bronner (Irene M.); M.J.M. Remmers (Michel ); H.P. Bienfait (Henri); R.J.G.M. Witjes (Ron J.G.M.); J.P. Greving (Jacoba); C.J.M. Klijn (Catharina J.M.); H.F. de Leeuw (Frank); H.B. Boogaarts; E.J. van Dijk (Ewoud); W.J. Schonewille; W.M.J. Pellikaan; C. Puppels-De Waard; P.L.M. De Kort; J.P. Peluso; J. van Tuijl (Jordie); J. Hofmeijer; F.B.M. Joosten (Frank); D.W.J. Dippel (Diederik); L. Khajeh (Ladbon); T.W.M. Raaijmakers; M.J. Wermer; M.A.A. van Walderveen (Marianne); H. Kerkhoff; E. Zock; K. Jellema (Korné); G.J. Lycklama à Nijeholt (Geert); I.M. Bronner; M.J.M. Remmers; R.J.G.M. Witjes; H.P. Bienfait; K.E. Droogh-Greve; R. Donders (Rogier); V.I.H. Kwa; T.H.C.M.L. Schreuder (Tobien H. C. M. L.); C.L. Franke (Cees); J.S. Straver; C. Jansen; S.L.M. Bakker (Stef); C.C. Pleiter (C.); M.C. Visser; C.J.J. Van Asch; B.K. Velthuis (Birgitta); G.J.E. Rinkel (Gabriel); K.M. Van Nieuwenhuizen; C.J.M. Klijn (Catharina J.M.)

    2015-01-01

    textabstractStudy question What are the diagnostic yield and accuracy of early computed tomography (CT) angiography followed by magnetic resonance imaging/angiography (MRI/MRA) and digital subtraction angiography (DSA) in patients with non-traumatic intracerebral haemorrhage? Methods This

  7. Contrast-enhanced MR angiography vs intra-arterial digital subtraction angiography for carotid imaging: activity-based cost analysis

    International Nuclear Information System (INIS)

    U-King-Im, Jean Marie; Cross, Justin J.; Higgins, Nicholas J.; Graves, Martin J.; Antoun, Nagui M.; Gillard, Jonathan H.; Hollingworth, William; Trivedi, Rikin A.; Kirkpatrick, Peter J.

    2004-01-01

    The aim of this study was to compare the costs of performing contrast-enhanced MR angiography (CE MRA) with intra-arterial digital subtraction angiography (DSA) for the evaluation of carotid atherosclerotic disease. Activity-based cost analysis was used to identify the costs of performing each procedure. The variable direct costs of performing CE MRA and DSA were determined in 20 patients by using detailed time and motion studies. All personnel directly involved in the cases were tracked to the nearest minute and all consumable items used were recorded. Moreover, procedure times were prospectively recorded for an additional 80 patients who underwent both DSA and CE MRA. The variable direct costs of bed usage in the angiography day-case unit, all direct fixed costs as well as indirect costs were assessed from hospital and departmental accounting records. Total costs for each procedure were calculated and compared using Wilcoxon signed-rank sum test. Mean aggregate costs were and euro;721 for DSA and and euro;306 for CE MRA, resulting in potential savings of and euro;415 per patient (p<0.0001). On average, a DSA procedure thus cost approximately 2.4 (95% confidence intervals: 2.2-2.6) times more than CE MRA to our medical institution. Sensitivity analyses confirmed the robustness of our conclusions across wide ranges of plausible values for various parameters. Assuming equal diagnostic performance, institutions may have substantial cost savings if CE MRA is used instead of DSA for carotid imaging. (orig.)

  8. Contrast-enhanced MR angiography vs intra-arterial digital subtraction angiography for carotid imaging: activity-based cost analysis

    Energy Technology Data Exchange (ETDEWEB)

    U-King-Im, Jean Marie; Cross, Justin J.; Higgins, Nicholas J.; Graves, Martin J.; Antoun, Nagui M.; Gillard, Jonathan H. [University Department of Radiology, Addenbrooke' s Hospital, CB2 2QQ, Cambridge (United Kingdom); Hollingworth, William [Department of Radiology, University of Washington, WA 98103, Seattle (United States); Trivedi, Rikin A. [University Department of Radiology, Addenbrooke' s Hospital, CB2 2QQ, Cambridge (United Kingdom); Academic Department of Neurosurgery, Addenbrooke' s Hospital, CB2 2QQ, Cambridge (United Kingdom); Kirkpatrick, Peter J. [Academic Department of Neurosurgery, Addenbrooke' s Hospital, CB2 2QQ, Cambridge (United Kingdom)

    2004-04-01

    The aim of this study was to compare the costs of performing contrast-enhanced MR angiography (CE MRA) with intra-arterial digital subtraction angiography (DSA) for the evaluation of carotid atherosclerotic disease. Activity-based cost analysis was used to identify the costs of performing each procedure. The variable direct costs of performing CE MRA and DSA were determined in 20 patients by using detailed time and motion studies. All personnel directly involved in the cases were tracked to the nearest minute and all consumable items used were recorded. Moreover, procedure times were prospectively recorded for an additional 80 patients who underwent both DSA and CE MRA. The variable direct costs of bed usage in the angiography day-case unit, all direct fixed costs as well as indirect costs were assessed from hospital and departmental accounting records. Total costs for each procedure were calculated and compared using Wilcoxon signed-rank sum test. Mean aggregate costs were and euro;721 for DSA and and euro;306 for CE MRA, resulting in potential savings of and euro;415 per patient (p<0.0001). On average, a DSA procedure thus cost approximately 2.4 (95% confidence intervals: 2.2-2.6) times more than CE MRA to our medical institution. Sensitivity analyses confirmed the robustness of our conclusions across wide ranges of plausible values for various parameters. Assuming equal diagnostic performance, institutions may have substantial cost savings if CE MRA is used instead of DSA for carotid imaging. (orig.)

  9. Time-resolved MR angiography of the renal artery: morphology and perfusion

    International Nuclear Information System (INIS)

    Krause, U.J.; Pabst, T.; Koestler, H.; Helbig, C.; Kenn, W.; Hahn, D.

    2002-01-01

    Purpose: To prove the hypothesis that renal artery stenosis and changes in renal perfusion can be detected with contrast-enhanced time-resolved MR angiography in a single examination. Material and Methods: In 71 patients, 137 renal arteries and 14 accessory renal arteries were studied. The examinations were performed on a 1.5 T system. A T 1 -weighted gradient echo sequence with a temporal resolution of 7 s was used. Single dose of contrast material (0.1 mmol/kg Gd-DTPA) was injected with a power injector with a flow rate of 2 ml/s. Criterion for the assessment of renal perfusion was the slope ratio of the signal intensity time curve in both kidneys. Results: Forty renal artery stenoses and one occlusion of a renal artery were detected. In 48 kidneys (35%) segmental arteries were evaluated. The accuracy of the slope ratio (limit value 0.75) concerning the detection of unilateral renal artery stenosis was 92.6% (sensitivity 75%, specificity 95.7%). Conclusion: Time-resolved MR angiography can detect changes in renal perfusion in patients with unilateral renal artery stenosis. (orig.) [de

  10. Assessment of blood supply to intracranial pathologies in children using MR digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Chooi, Weng Kong; Coley, Stuart C. [Royal Hallamshire Hospital, Department of Radiology, Sheffield (United Kingdom); Connolly, Dan J.A. [Royal Hallamshire Hospital, Department of Radiology, Sheffield (United Kingdom); Sheffield Children' s Hospital, Department of Radiology, Sheffield (United Kingdom); Griffiths, Paul D. [Royal Hallamshire Hospital, Department of Radiology, Sheffield (United Kingdom); Sheffield Children' s Hospital, Department of Radiology, Sheffield (United Kingdom); University of Sheffield, Academic Unit of Radiology, Sheffield (United Kingdom); Floor C, Royal Hallamshire Hospital, Section of Academic Radiology, Sheffield (United Kingdom)

    2006-10-15

    MR digital subtraction angiography (MR-DSA) is a contrast-enhanced MR angiographic sequence that enables time-resolved evaluation of the cerebral circulation. We describe the feasibility and technical success of our attempts at MR-DSA for the assessment of intracranial pathology in children. We performed MR-DSA in 15 children (age range 5 days to 16 years) referred for MR imaging because of known or suspected intracranial pathology that required a dynamic assessment of the cerebral vasculature. MR-DSA consisted of a thick (6-10 mm) slice-selective RF-spoiled fast gradient-echo sequence (RF-FAST) acquired before and during passage of an intravenously administered bolus of Gd-DTPA. The images were subtracted and viewed as a cine loop. MR-DSA was performed successfully in all patients. High-flow lesions were shown in four patients; these included vein of Galen aneurysmal malformation, dural fistula, and two partially treated arteriovenous malformations (AVMs). Low-flow lesions were seen in three patients, all of which were tumours. Normal flow was confirmed in eight patients including two with successfully treated AVMs, and in three patients with cavernomas. Our early experience suggests that MR-DSA is a realistic, non-invasive alternative to catheter angiography in certain clinical settings. (orig.)

  11. Assessment of blood supply to intracranial pathologies in children using MR digital subtraction angiography

    International Nuclear Information System (INIS)

    Chooi, Weng Kong; Coley, Stuart C.; Connolly, Dan J.A.; Griffiths, Paul D.

    2006-01-01

    MR digital subtraction angiography (MR-DSA) is a contrast-enhanced MR angiographic sequence that enables time-resolved evaluation of the cerebral circulation. We describe the feasibility and technical success of our attempts at MR-DSA for the assessment of intracranial pathology in children. We performed MR-DSA in 15 children (age range 5 days to 16 years) referred for MR imaging because of known or suspected intracranial pathology that required a dynamic assessment of the cerebral vasculature. MR-DSA consisted of a thick (6-10 mm) slice-selective RF-spoiled fast gradient-echo sequence (RF-FAST) acquired before and during passage of an intravenously administered bolus of Gd-DTPA. The images were subtracted and viewed as a cine loop. MR-DSA was performed successfully in all patients. High-flow lesions were shown in four patients; these included vein of Galen aneurysmal malformation, dural fistula, and two partially treated arteriovenous malformations (AVMs). Low-flow lesions were seen in three patients, all of which were tumours. Normal flow was confirmed in eight patients including two with successfully treated AVMs, and in three patients with cavernomas. Our early experience suggests that MR-DSA is a realistic, non-invasive alternative to catheter angiography in certain clinical settings. (orig.)

  12. Assessment of blood supply to intracranial pathologies in children using MR digital subtraction angiography.

    Science.gov (United States)

    Chooi, Weng Kong; Connolly, Dan J A; Coley, Stuart C; Griffiths, Paul D

    2006-10-01

    MR digital subtraction angiography (MR-DSA) is a contrast-enhanced MR angiographic sequence that enables time-resolved evaluation of the cerebral circulation. We describe the feasibility and technical success of our attempts at MR-DSA for the assessment of intracranial pathology in children. We performed MR-DSA in 15 children (age range 5 days to 16 years) referred for MR imaging because of known or suspected intracranial pathology that required a dynamic assessment of the cerebral vasculature. MR-DSA consisted of a thick (6-10 mm) slice-selective RF-spoiled fast gradient-echo sequence (RF-FAST) acquired before and during passage of an intravenously administered bolus of Gd-DTPA. The images were subtracted and viewed as a cine loop. MR-DSA was performed successfully in all patients. High-flow lesions were shown in four patients; these included vein of Galen aneurysmal malformation, dural fistula, and two partially treated arteriovenous malformations (AVMs). Low-flow lesions were seen in three patients, all of which were tumours. Normal flow was confirmed in eight patients including two with successfully treated AVMs, and in three patients with cavernomas. Our early experience suggests that MR-DSA is a realistic, non-invasive alternative to catheter angiography in certain clinical settings.

  13. A simulation study of enhancement duration in three-dimensional contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Ohkubo, Masaki; Ohgoshi, Yukio; Inoue, Tomoko; Naito, Kenichi; Suzuki, Kiyotaka

    2001-01-01

    In our study on three-dimensional (3D) contrast-enhanced MR angiography we performed a computer simulation to investigate quantitative vessel visibility. In the simulation, we evaluated the relative loss of signal intensity in a vessel due to shortened duration of contrast-enhancement. The mid-point of enhancement-duration was assumed to be at the point in which the data in the center of k-space (k y axis) was acquired. Signal intensity of a vessel decreased as the enhancement-duration was shortened and the diameter of the vessel was decreased. When the duration was shortened 40%, the signal intensity of a vessel in which the diameter was more than 2 pixels was preserved by approximately 70% or more. This suggests that the vessel visibility is high. When the duration was shortened 20%, the signal intensity of a vessel in which the diameter was less than 2 pixels decreased to less than approximately 40% or less. The simulation was confirmed by using 3D MR angiography with a tube phantom filled with Gd-DTPA to simulate a vessel model. At anytime during data acquisition, we could set the phantom on the region being scanned or take it out by using the ''pause'' function of the MR scanner. This made it possible to change the enhancement-duration to match the simulation. Results of the phantom study were comparable to those of the simulation, suggesting that the simulation was valid. Our results and simple techniques for both the simulation and the phantom study using the ''pause'' function, were considered useful in the study of 3D MR angiography. (author)

  14. Evaluation of the portal venous system using MR angiography in patients with severe liver dysfunction

    International Nuclear Information System (INIS)

    Fukatsu, Hiroshi; Ando, Yoko; Yamakawa, Koji; Ishigaki, Takeo

    1994-01-01

    Fifteen patients of chronic liver dysfunction were examined with 2D TOF MR angiography to assess the portal venous system condition. All of the collateral pathways except esophageal varices were clearly demonstrated in all cases, portal vein thromboses were accurately diagnosed in two cases. Portal vein visualization index were determined as follows: good delineation of the main portal vein only; good delineation of the first tributaries of the intrahepatic portal vein; good delineation of the second or further tributaries. This index showed good correlation with the clinical stage proposed by Japan liver cancer study group. These results suggested that MR angiography has a potential for the evaluation of the portal system in patients with severe liver dysfunction. (author)

  15. Maximum intensity projection MR angiography using shifted image data

    International Nuclear Information System (INIS)

    Machida, Yoshio; Ichinose, Nobuyasu; Hatanaka, Masahiko; Goro, Takehiko; Kitake, Shinichi; Hatta, Junicchi.

    1992-01-01

    The quality of MR angiograms has been significantly improved in past several years. Spatial resolution, however, is not sufficient for clinical use. On the other hand, MR image data can be filled at anywhere using Fourier shift theorem, and the quality of multi-planar reformed image has been reported to be improved remarkably using 'shifted data'. In this paper, we have clarified the efficiency of 'shifted data' for maximum intensity projection MR angiography. Our experimental studies and theoretical consideration showd that the quality of MR angiograms has been significantly improved using 'shifted data' as follows; 1) remarkable reduction of mosaic artifact, 2) improvement of spatial continuity for the blood vessels, and 3) reduction of variance for the signal intensity along the blood vessels. In other words, the angiograms looks much 'finer' than conventional ones, although the spatial resolution is not improved theoretically. Furthermore, we found the quality of MR angiograms dose not improve significantly with the 'shifted data' more than twice as dense as ordinal ones. (author)

  16. Diagnosis of the hypothenar hammer syndrome by high-resolution contrast-enhanced MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Winterer, J.T.; Ghanem, N.; Schaefer, O.; Lehnhardt, S.; Thuerl, C.; Laubenberger, J. [Department of Diagnostic Radiology, University of Freiburg, Hugstetter Strasse 55, 79106 Freiburg (Germany); Roth, M. [Center of Geriatric Medicine and Gerontology Freiburg, University of Freiburg, Hugstetter Strasse 55, 79106 Freiburg (Germany); Horch, R.E. [Department of Plastic and Hand Surgery, University of Freiburg, Hugstetter Strasse 55, 79106 Freiburg (Germany)

    2002-10-01

    Our objective was to describe the imaging features of hypothenar hammer syndrome using minimally invasive contrast-enhanced MR angiography in comparison with oscillography study. In five patients with hypothenar hammer syndrome Gd-BOPTA-enhanced elliptically reordered 3D pulse sequence MR was compared with oscillography findings and clinical symptoms focusing on angiographic appearance of vessel injury, distribution pattern of hand vasculature and joining branches between the radial and ulnar artery supply. All patients showed segmental occlusion at the site of trauma impact with varying involvement of the superficial palmar arch, common volar digital arteries. Embolic disease was present in 50% of patients and could be clearly identified with MRA. Good correspondence was found between angiographic appearance including the presence of collaterals, clinical symptoms and oscillography. Bilateral comparison was helpful in distinguishing between vessel variants and pathology. Bilateral Gd-BOPTA-enhanced MR angiography is a minimally invasive method to depict clearly the localization and extent of vessel injury in hypothenar hammer syndrome providing valuable information about distribution pattern of hand vasculature and presence of collaterals; however, no flow data can be obtained. (orig.)

  17. Diagnosis of the hypothenar hammer syndrome by high-resolution contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Winterer, J.T.; Ghanem, N.; Schaefer, O.; Lehnhardt, S.; Thuerl, C.; Laubenberger, J.; Roth, M.; Horch, R.E.

    2002-01-01

    Our objective was to describe the imaging features of hypothenar hammer syndrome using minimally invasive contrast-enhanced MR angiography in comparison with oscillography study. In five patients with hypothenar hammer syndrome Gd-BOPTA-enhanced elliptically reordered 3D pulse sequence MR was compared with oscillography findings and clinical symptoms focusing on angiographic appearance of vessel injury, distribution pattern of hand vasculature and joining branches between the radial and ulnar artery supply. All patients showed segmental occlusion at the site of trauma impact with varying involvement of the superficial palmar arch, common volar digital arteries. Embolic disease was present in 50% of patients and could be clearly identified with MRA. Good correspondence was found between angiographic appearance including the presence of collaterals, clinical symptoms and oscillography. Bilateral comparison was helpful in distinguishing between vessel variants and pathology. Bilateral Gd-BOPTA-enhanced MR angiography is a minimally invasive method to depict clearly the localization and extent of vessel injury in hypothenar hammer syndrome providing valuable information about distribution pattern of hand vasculature and presence of collaterals; however, no flow data can be obtained. (orig.)

  18. Three-dimensional magnetic resonance angiography of vascular lesions in children.

    Science.gov (United States)

    Katayama, H; Shimizu, T; Tanaka, Y; Narabayashi, I; Tamai, H

    2000-01-01

    We applied three-dimensional (3D) magnetic resonance (MR) angiography to vascular lesions in children and evaluated the clinical usefulness of this technique. Ten patients, whose ages ranged from 1 month to 16 years, underwent 3D MR angiography for 12 vascular lesions, including lesions in seven pulmonary arteries, two thoracic aortae, a pair of renal arteries, and one iliac artery. Three-dimensional MR angiography was performed with body-or pelvic-phased array coils on a 1.5-T scanner using fast spoiled gradient echo sequence. Data were acquired with the following parameters: TE, 1.9 ms; TR, 10.1 ms; flip angle, 20-60 degrees ; 1 or 2 NEX; field of view, 24-48 x 18-40 cm; matrix, 256 or 512 x 128 or 256; slice thickness, 1.2-7.5 mm; and 12, 28, or 60 partitions. Vascular imaging was enhanced with 20% gadolinium-diethylenetriaminepentaacetic acid. The examination was performed under breath-holding in six patients and with shallow breathing in four patients. In a comparative study with other noninvasive methods, 3D MR angiography was superior in seven of nine cases to other noninvasive examinations and in two cases, all methods evaluated the lesions. Furthermore, six cases were compared with conventional angiography. In five of the six cases, both methods depicted the lesions similarly, and in one case, MR angiography was more effective. A quantitative comparison of vascular diameter in the MR image was made with that in the conventional angiographic image. The correlation between them was excellent: y = 1.145x-2.090 (r = 0.987; P children.

  19. Angiography and interventional radiology of the kidneys; Angiographie und interventionelle Radiologie der Nieren

    Energy Technology Data Exchange (ETDEWEB)

    Hansmann, J.; Richter, G.M.; Hallscheidt, P.; Duex, M.; Noeldge, G.; Kaufmann, G.W. [Heidelberg Univ. (Germany). Abt. Radiodiagnostik

    1999-05-01

    For imaging of renal pathology a broad spectrum of radiologic diagnostic procedures are available which are, sometimes and particularly more recently, competing among each other in their diagnostic yield and relevance. For tumorous lesions ultrasound, computed tomography and magnetic resonance imaging are performed predominantly. Angiography is no longer required with the exception of highly selected cases and in some specific preoperative workup requirements. Until recently, catheter based digital subtraction angiography has been considered as gold standard. However, non-invasive techniques such as CT-angiography and MR-angiography are evolving parallel to their quantum leap of resolutions and readiness to use. Nevertheless, well accepted criteria for quality assessement of these new modalities are still lacking. More comparison studies are urgently warranted. Despite the availability of ultrashort pulse sequences applying the T1 relaxation reduction effect of gadolinium enhanced MR techniques overestimation of renal artery stenosis still poses a substantial problem. Renal intervention implies a variety of procedures such as plain angioplasty, stent placement, embolization of traumatic and both benign and malignant tumors. These methods have emerged over the last two decades from a more experimental nature to a fully accepted treatment option. When renal artery angioplasty is embedded in an aggressive approach including stenting as an adjunct for more complex cases, renal ostial lesions and a well organized follow-up regimen its therapeutic potential for treatment of renal insufficiency, malignant hypertension, for organ preservation bears a very high potential. Provided adequate periinterventional drug regimen restenosis rates may be as low as 10%. In highly selected cases capillary embolization might be used as an alternative to nephrectomy with a similar clinical outcome. Particularly the development of superselective small caliber embolization catheters

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography uses a catheter, x-ray ... are the limitations of Catheter Angiography? What is Catheter Angiography? Angiography is a minimally invasive medical test ...

  1. MR angiography of cerebral aneurysms

    International Nuclear Information System (INIS)

    Miki, Hitoshi; Tanada, Shuji; Sakaki, Saburo; Hamamoto, Ken; Sadamoto, Kazuhiko.

    1992-01-01

    Time-of-flight (TOF) MR angiography (MRA) and phase-contrast (PC) MRA are examined clinically for evaluating cerebral aneurysms. In the morphological diagnosis of cerebral aneurysms, three-dimensional (3D) MRA is superior to two-dimensional (2D) MRA because 3D MRA has a higher S/N ratio and a higher spatial resolution. However, it is difficult to decide which, 3D TOF MRA or 3D PC MRA, is superior, for both methods have many scan parameters. In our study, 3D PC MRA was performed using two methods; one had the same acquisition time as 3D TOF MRA, while the other had the same spatial resolution as 3D TOF MRA. The detectability of aneurysms by each MRA method was evaluated in comparison with 3D TOF MRA. In fifteen patients (6 males and 9 females), a total of 16 cerebral aneurysms (3 ruptured and 13 unruptured) were studied. The lesion sizes ranged from 2.5 to 18 mm. All the 16 lesions were examined by means of 3D TOF MRA, 3D PC MRA, and conventional angiography. MR imaging was performed with a 1.5 tesla MRI system (Signa). All of the 16 cerebral aneurysms were detected by 3D TOF MRA, while only 11 of them were detected by 3D PC MRA. When 3D PC MRA was performed with the same acquisition time as 3D TOF MRA, 3D PC MRA was superior in showing one of the 7 aneurysms. When 3D PC MRA was performed with same spatial resolution as 3D TOF MRA, 3D PC MRA was superior in showing two of the 10 aneurysms. 3D TOF MRA was superior to 3D PC MRA in the detection of cerebral aneurysms because of the long acquisition times and the different flow velocity, which induced different signal intensities between the aneurysms and parent arteries in 3D PC MRA. 3D PC MRA was superior to 3D TOF MRA in patients with large thrombotic aneurysms of the internal carotid artery. We consider that 3D TOF MRA should be the first choice for screening and following-up cerebral aneurysms. 3D PC MRA should then be performed for large cerebral aneurysms in addition to 3D TOF MRA. (author)

  2. CT Angiography in the Diagnosis of Brain Death

    International Nuclear Information System (INIS)

    Sawicki, Marcin; Bohatyrewicz, Romuald; Walecka, Anna; Sołek-Pastuszka, Joanna; Rowiński, Olgierd; Walecki, Jerzy

    2014-01-01

    Summary Brain death is defined as the irreversible cessation of functioning of the entire brain, including the brainstem. Brain death is principally established using clinical criteria including coma, absence of brainstem reflexes and loss of central drive to breathe assessed with apnea test. In situations in which clinical testing cannot be performed or when uncertainty exists about the reliability of its parts due to confounding conditions ancillary tests (i.a. imaging studies) may be useful. The objective of ancillary tests in the diagnosis of brain death is to demonstrate the absence of cerebral electrical activity (EEG and evoked potentials) or cerebral circulatory arrest. In clinical practice catheter cerebral angiography, perfusion scintigraphy, transcranial Doppler sonography, CT angiography and MR angiography are used. Other methods, like perfusion CT, xenon CT, MR spectroscopy, diffusion weighted MRI and functional MRI are being studied as potentially useful in the diagnosis of brain death. CT angiography has recently attracted attention as a promising alternative to catheter angiography – a reference test in the diagnosis of brain death. Since 1998 several major studies were published and national guidelines were introduced in several countries (e.g. in France, Austria, Switzerland, the Netherlands and Canada). This paper reviews technique, characteristic findings and criteria for the diagnosis of cerebral circulatory arrest in CT angiography

  3. Intra-Arterial MR Perfusion Imaging of Meningiomas: Comparison to Digital Subtraction Angiography and Intravenous MR Perfusion Imaging.

    Directory of Open Access Journals (Sweden)

    Mark A Lum

    Full Text Available To evaluate the ability of IA MR perfusion to characterize meningioma blood supply.Studies were performed in a suite comprised of an x-ray angiography unit and 1.5T MR scanner that permitted intraprocedural patient movement between the imaging modalities. Patients underwent intra-arterial (IA and intravenous (IV T2* dynamic susceptibility MR perfusion immediately prior to meningioma embolization. Regional tumor arterial supply was characterized by digital subtraction angiography and classified as external carotid artery (ECA dural, internal carotid artery (ICA dural, or pial. MR perfusion data regions of interest (ROIs were analyzed in regions with different vascular supply to extract peak height, full-width at half-maximum (FWHM, relative cerebral blood flow (rCBF, relative cerebral blood volume (rCBV, and mean transit time (MTT. Linear mixed modeling was used to identify perfusion curve parameter differences for each ROI for IA and IV MR imaging techniques. IA vs. IV perfusion parameters were also directly compared for each ROI using linear mixed modeling.18 ROIs were analyzed in 12 patients. Arterial supply was identified as ECA dural (n = 11, ICA dural (n = 4, or pial (n = 3. FWHM, rCBV, and rCBF showed statistically significant differences between ROIs for IA MR perfusion. Peak Height and FWHM showed statistically significant differences between ROIs for IV MR perfusion. RCBV and MTT were significantly lower for IA perfusion in the Dural ECA compared to IV perfusion. Relative CBF in IA MR was found to be significantly higher in the Dural ICA region and MTT significantly lower compared to IV perfusion.

  4. Preoperative evaluation of the artery of adamkiewicz by MR angiography and CT angiography in patients with a thoracic aortic aneurysm

    International Nuclear Information System (INIS)

    Niinuma, Hiroyuki; Ohira, Atsushi; Makita, Shinji; Moriai, Yoshiteru; Hiramori, Katsuhiko; Yoshioka, Kunihiro; Nakajima, Takayuki; Kawazoe, Kohei

    2002-01-01

    Paraplegia is known as an extremely serious and important complication of surgical repair in patients with a thoraco-abdominal aortic aneurysm. It is important to evaluate the artery of Adamkiewicz (AdA) before surgical repair to prevent paraplegia. But the AdA is difficult to visualize by the invasive and hazardous, conventional selective angiography. The aim of this study was to visualize AdA by MR angiography (MRA) and CT angiography (CTA). Twenty-one consecutive patients with a thoracic aortic aneurysm underwent both gadolinium-enhanced, three-dimensional MRA and CTA using multislice helical CT. The AdA was successfully visualized in 15 of the 21 patients (71.4%) by MRA, and in 17 of those 21 patients (80.9%) by CTA. Its continuity was depicted in 12 of 15 patients (80%) by MRA, and in 9 of 17 patients (47%) by CTA. AdA was visualized at 85.7% by MRA or CTA, respectively. This study shows that CTA is a much more sensitive method to detect AdA than MRA. On the other hand, MRA is better to evaluate the continuity of AdA from the descending aorta to the anterior spinal artery, than CTA. Therefore, MRA and CTA are both useful for a preoperative evaluation of AdA and its detailed vascular anatomy from the aorta to the anterior spinal artery. (author)

  5. Generalised brain edema and brain infarct in ergotamine abuse: Visualization by CT, MR and angiography

    International Nuclear Information System (INIS)

    Toedt, C.; Hoetzinger, H.; Salbeck, R.; Beyer, H.K.

    1989-01-01

    Abuse of ergotamine can release a generalised brain edema and brain infarctions. This can be visualized by CT, MR and angiography. The reason, however, can only be found in the patients history. (orig.) [de

  6. MR angiography in the evaluation of a renovascular cause of neonatal hypertension

    International Nuclear Information System (INIS)

    Mustafa, Amira E.; Valentini, Rudolph P.; Mattoo, Tej K.; Bloom, David A.; Imam, Abubakr A.

    2006-01-01

    Neonatal hypertension occurs in 2% of all infants and it is caused by renovascular abnormalities in 70% of these infants. The gold standard for diagnosing renovascular disease is conventional renal angiography. However, in neonates the procedure is not commonly used because of its invasive and technically challenging nature. MRI and MR angiography (MRA) are less invasive yet reliable means of detecting renovascular disease in adults. There is minimal literature on the use of MRI/MRA in neonatal hypertension. We report a neonate with hypertension secondary to a renovascular abnormality in which MRI/MRA was helpful in uncovering segmental renal artery stenosis. The infant underwent partial nephrectomy with subsequent resolution of his hypertension. Further studies are needed to validate the use of MRI/MRA in the evaluation of neonatal hypertension. (orig.)

  7. MR Angiography for the Evaluation of Non-Systemic Vasculitic Neuropathy

    International Nuclear Information System (INIS)

    Sanada, M.; Terada, M.; Yasuda, H.; Suzuki, E.; Kashiwagi, A.

    2003-01-01

    Peripheral neuropathy due to vasculitis without any complications of vasculitis in other organs was first reported in 1987. This condition was termed non-systemic vasculitic neuropathy (NSVN). Although vasculitis is believed to develop in small arteries and arterioles in this disease, the level of vascular involvement has not been fully established. We present a case of NSVN followed up by MR angiography, which was thought to be useful to assess the level as well as the state of vascular lesions in this condition

  8. MR Angiography for the Evaluation of Non-Systemic Vasculitic Neuropathy

    Energy Technology Data Exchange (ETDEWEB)

    Sanada, M.; Terada, M.; Yasuda, H. [Shiga Univ. of Medical Science (Japan). Div. of Neurology; Suzuki, E.; Kashiwagi, A. [Shiga Univ. of Medical Science (Japan). Div. of Endocrinology and Metabolism

    2003-05-01

    Peripheral neuropathy due to vasculitis without any complications of vasculitis in other organs was first reported in 1987. This condition was termed non-systemic vasculitic neuropathy (NSVN). Although vasculitis is believed to develop in small arteries and arterioles in this disease, the level of vascular involvement has not been fully established. We present a case of NSVN followed up by MR angiography, which was thought to be useful to assess the level as well as the state of vascular lesions in this condition.

  9. Carotid-anterior cerebral artery anastomosis on MR angiography: a university hospital-based study

    Energy Technology Data Exchange (ETDEWEB)

    Uchino, Akira; Saito, Naoko; Okada, Yoshitaka; Inoue, Kaiji [Saitama Medical University International Medical Center, Department of Diagnostic Radiology, Hidaka, Saitama (Japan)

    2012-01-15

    Rarely in the anterior circulation, an anastomosis of the carotid and anterior cerebral arteries occurs when an anomalous branch arises from the ophthalmic segment of the internal carotid artery and anastomoses with the A1-A2 junction of the anterior communicating artery. Right-side predominance is known. To our knowledge, the incidence of carotid-anterior cerebral artery anastomosis has not been reported, so we researched cases in our institution records to determine incidence and investigated characteristic features of the condition on magnetic resonance (MR) angiography. To isolate such cases, we retrospectively reviewed cranial MR angiographic images of 3,491 consecutive patients in our institution. We found three cases with carotid-anterior cerebral artery anastomosis (two men, one woman), representing an incidence of 0.086%. The anastomosis was on the right in all three cases. A normal A1 segment of the anterior cerebral artery (ACA) was present in two cases but could not be identified in the remaining case on MR angiographic images that included source images. Two of the three patients demonstrated associated arterial variations in their carotid systems. On MR angiography, we observed a 0.086% incidence of carotid-anterior cerebral artery anastomosis in our institution and reaffirmed the right-side predominance of this anomaly. We found a high frequency of other associated arterial variations in the carotid system. (orig.)

  10. Evaluation of diagnostic accuracy of cerebral aneurysms on MR angiography

    International Nuclear Information System (INIS)

    Miki, Hitoshi

    1996-01-01

    The purpose of this study was to evaluate the diagnostic accuracy of MR angiography (MRA) for detection of intracranial aneurysms (IAs) by prospective and retrospective examinations. The detection rates for MRA were: 3D time-of-flight (TOF), 94.2% (n=69); 3D phase contrast (PC), 75% (n=20); 2D TOF, 68% (n=25); and 2D PC, 59.4% (n=32). In aneurysms smaller than 5-mm, the detection rates were: 3D TOF, 87.9% (n=33); 3D PC, 42.9% (n=7); 2D TOF, 0% (n=8); and 2D PC, 14.3% (n=14). In the detection of IAs smaller than 5-mm, 3D TOF was superior to other MRA methods. Four IAs could not be detected by 3D TOF with a standard voxel size. These four IAs smaller than 3-mm were detected by 3D TOF with a small voxel size. In the blinded examination, the detection rate of IAs using MIP images was 71.8%, however, it using MIP and source images was 93.5%. False positive cases were reduced by using source images. In prospective study including 200 cases, IAs smaller than 5-mm were detected in 12 individuals underwent conventional angiography or CT angiography. Seven of them were true positive, however, 5 smaller than 2-mm on MRA were false positive. In conclusions, IAs 3-mm or larger can be identified by 3D TOF MRA with a small voxel size; however, IAs smaller than 2-mm on MRA are difficult to detect without false positive. (author)

  11. Fusion of CT Angiography or MR Angiography with Unenhanced CBCT and Fluoroscopy Guidance in Endovascular Treatments of Aorto-Iliac Steno-Occlusion: Technical Note on a Preliminary Experience

    Energy Technology Data Exchange (ETDEWEB)

    Ierardi, Anna Maria; Duka, Ejona [University of Insubria, Interventional Radiology, Department of Radiology (Italy); Radaelli, Alessandro [Philips Healthcare (Netherlands); Rivolta, Nicola; Piffaretti, Gabriele [University of Insubria, Vascular Surgery Department (Italy); Carrafiello, Gianpaolo, E-mail: gcarraf@gmail.com [University of Insubria, Interventional Radiology, Department of Radiology (Italy)

    2016-01-15

    AimTo evaluate the feasibility of image fusion (IF) of pre-procedural arterial-phase CT angiography or MR angiography with intra-procedural fluoroscopy for road-mapping in endovascular treatment of aorto-iliac steno-occlusive disease.Materials and MethodsBetween September and November, 2014, we prospectively evaluated 5 patients with chronic aorto-iliac steno-occlusive disease, who underwent endovascular treatment in the angiography suite. Fusion image road-mapping was performed using angiographic phase CT images or MR images acquired before and intra-procedural unenhanced cone-beam CT. Radiation dose of the procedure, volume of intra-procedural iodinated contrast medium, fluoroscopy time, and overall procedural time were recorded. Reasons for potential fusion imaging inaccuracies were also evaluated.ResultsImage co-registration and fusion guidance were feasible in all procedures. Mean radiation dose of the procedure was 60.21 Gycm2 (range 55.02–63.75 Gycm2). The mean total procedure time was 32.2 min (range 27–38 min). The mean fluoroscopy time was 12 min and 3 s. The mean procedural iodinated contrast material dose was 24 mL (range 20–40 mL).ConclusionsIF gives Interventional Radiologists the opportunity to use new technologies in order to improve outcomes with a significant reduction of contrast media administration.

  12. Fusion of CT Angiography or MR Angiography with Unenhanced CBCT and Fluoroscopy Guidance in Endovascular Treatments of Aorto-Iliac Steno-Occlusion: Technical Note on a Preliminary Experience

    International Nuclear Information System (INIS)

    Ierardi, Anna Maria; Duka, Ejona; Radaelli, Alessandro; Rivolta, Nicola; Piffaretti, Gabriele; Carrafiello, Gianpaolo

    2016-01-01

    AimTo evaluate the feasibility of image fusion (IF) of pre-procedural arterial-phase CT angiography or MR angiography with intra-procedural fluoroscopy for road-mapping in endovascular treatment of aorto-iliac steno-occlusive disease.Materials and MethodsBetween September and November, 2014, we prospectively evaluated 5 patients with chronic aorto-iliac steno-occlusive disease, who underwent endovascular treatment in the angiography suite. Fusion image road-mapping was performed using angiographic phase CT images or MR images acquired before and intra-procedural unenhanced cone-beam CT. Radiation dose of the procedure, volume of intra-procedural iodinated contrast medium, fluoroscopy time, and overall procedural time were recorded. Reasons for potential fusion imaging inaccuracies were also evaluated.ResultsImage co-registration and fusion guidance were feasible in all procedures. Mean radiation dose of the procedure was 60.21 Gycm2 (range 55.02–63.75 Gycm2). The mean total procedure time was 32.2 min (range 27–38 min). The mean fluoroscopy time was 12 min and 3 s. The mean procedural iodinated contrast material dose was 24 mL (range 20–40 mL).ConclusionsIF gives Interventional Radiologists the opportunity to use new technologies in order to improve outcomes with a significant reduction of contrast media administration

  13. Gadolinium-enhanced MR angiography of the thoracoabdominal aorta diseases

    International Nuclear Information System (INIS)

    D'Ippolito, Giuseppe; Wolosker, Nelson; Galvao Filho, Mario; Kalil, Jorge A.; Wolosker, Angela; Borri, Maria Lucia

    1998-01-01

    Gadolinium-enhanced MR angiography (GEMRA) of the thoracoabdominal aorta is a noninvasive technique that can rapidly delineate the branch vessels diseases, without flow or respiration artifacts, obtained with non contrast MRA. The objective of this paper is to show the main clinical applications of GEMRA, compared to non contrast sequences. We have evaluated 30 patients with thorocoabdominal aorta diseases. These patients have been examined with GEMRA (3D, FFE sequences) obtained after 30 mlIV contrast injection and non contrast MRA (2D-TOF sequences). In our experience, gadolinium-enhanced MRA is a high resolution and speedy technique with advantages over non contrast MRA. (author)

  14. Angiography

    International Nuclear Information System (INIS)

    Grinnell, V.S.; Mehringer, C.M.; Hieshima, G.B.

    1987-01-01

    The history of angiography is short, with its centennial approaching. A very brief review of milestones begins with the discovery of x-rays in 1895. Only a few months later contrast agents too toxic for human use were being injected into cadavers, severed limbs, and animals. The next major developments came in the late 1970s when percutaneous translumbar aortography and cerebral angiography were described. Contrast agents were now less toxic, and clinically useful angiography was a reality. In 1953 a technique for percutaneous vascular catheterization which formed the basis of many catheterization techniques to follow was described. In the 1970s the development of less invasive diagnostic methods such as computed tomography and diagnostic ultrasound decreased the indications for angiography, but newer interventional techniques such as embolization therapy and angioplasty have taken up the slack. Angiography remains the most important way to demonstrate vascular diseases graphically. Specific techniques such as angioplasty and digital subtraction angiography will be dealt with in other chapters. The authors hope to provide an overview of major areas of angiographic utilization. The basic techniques of arterial puncture and catheterization have been well described elsewhere

  15. Prevalence of Unruptured Intracranial Aneurysm on MR Angiography

    International Nuclear Information System (INIS)

    Jeon, Tae Yeon; Jeon, Pyoung; Kim, Keon Ha

    2011-01-01

    To evaluate the prevalence of incidentally found unruptured intracranial aneurysms (UIAs) on the brain MR angiography (MRA) from a community-based general hospital. This was a prospectively collected retrospective study, carried out from January 2004 to December 2004. The subjects included 3049 persons from a community-based hospital in whom MRA was performed according to a standardized protocol in an outpatient setting. Age- and sex-specific prevalence of UIAs was calculated. The results by MRA were compared with intra-arterial digital subtraction angiography (DSA) findings. Unruptured intracranial aneurysms were found in 137 (5%) of the 3049 patients (M:F 43:94; mean age, 60.2 years). The prevalence of UIAs was 5% (n = 94) in women and 4% (n = 43) in men, respectively (p = 0.2046) and showed no age-related increase. The most common site of aneurysm was at the distal internal carotid artery (n = 64, 39%), followed by the middle cerebral artery (n = 40, 24%). In total, 99% of aneurysms measured less than 12 mm, and 93% of aneurysms measured less than 7 mm. Direct comparisons between MRA and DSA were available in 70 patients with 83 UIAs; the results revealed two false positive and two false negative results. This community-hospital based study suggested a higher prevalence of UIAs observed by MRA than previously reported. These findings should be anticipated in the design and use of neuroimaging in clinical practice.

  16. MR angiography of the cerebral vessels with inflow-increased visualization by overcontiguous imaging and advanced processing

    International Nuclear Information System (INIS)

    McLachian, S.; Simon, H.E.; de Graaf, R.; Ho, A.M.; Ruccio, W.J.; Steidley, J.W.; Pradhan, R.B.

    1989-01-01

    The purpose of this study was to increase the visualization of cerebral vessels with MR angiography by using an inflow technique from transverse sections. Difficulties with visualization include the tortuous nature of the vessels and slow blood flow. The MR method is a transverse two-dimensional multiple single-section sequence with a velocity-compensated gradient echo and presaturation. A S15 imager with 10-mTm gradients and a prototype angiographic package is used. Overcontiguous acquisition yields smaller effective center-to-center sections. Interpolation is used to generate interleaved plane projections. A combination of image parameter swill reduce the level of the stationary tissue relative to the flowing blood. For vessels that are not perpendicular to the section, overlapping the sections by 25%--33% is shown to reduce the staircase appearance without affecting the apparent size of the vessels. Interpolation of the MR images will further reduce this artifact, giving the vessels a smooth structure. MR angiography of the brain performed with an inflow technique allows the visualization of vessels in the brain even if the vessels follow tortuous paths. Presaturation and user-defined regions of interest can be used for ease of interpretation

  17. Usefulness of three-dimensional contrast-enhanced MR angiography in the evaluation of pelvic and lower extremity arteries

    International Nuclear Information System (INIS)

    Kim, Young Kon; Han, Young Min; Lee, Jeong Min

    2002-01-01

    To evaluate the feasibility and clinical usefulness of three-dimensional contrast-enhanced MR angiography (3D-CE-MRA) as a screening test in the evaluation of pelvic and lower extremity arterial diseases. Forty-four patients who underwent 3D-CE-MRA were included in this study. Coronal 3-dimensional gradient-echo, pre-and post contrast image were acquired with a dedicated peripheral vascular coil and moving-bed technique on a 1.5T MR system. Timing of start of data acquisition was determined by MR fluoroscopy technique, and 0.2 mmol/kg Gd-DTPA was injected into an antecubital vein, at a rate of 1cc/sec with an autoinjector. For quantitative analysis, signal to noise ratio (SNR) and artery to soft tissue contrast to noise ratio (CNR) of lower extremities arterial system including lower abdominal aorta were calculated. For qualitative analysis, arterial systems were divided into six segments, and were evaluated in terms of conspicuity of arterial systems and the degree of venous enhancement by three- and four-point scale respectively. In eight patients who underwent both MR angiography and conventional angiography as standard reference. Imaging analysis was done by means of consensus between two experienced radiologists. The mean time for the examination was about 15 min (± 5 min). The mean SNR of arterial system was 26.5±11.6, and mean artery to soft tissue contrast to noise ratio (CNR) was 24.6±11.2. Among the total 525 arterial segments 498 arterial segments (94.5%) could be demonstrated with good delineation of entire arterial tree. Good arterial imaging without or with minimal venous enhancement were demonstrated in 98.5% (260/264) in above knee and 89% (211/261) in below knee (p<0.01). Ten of 525 segments (1.9%) demonstrated severe venous overlapping and it mostly occurred in the calf region. In comparison with DSA, the sensitivity and the specificity for MR angiography for the detection of occlusions were 96% and 98.8%, respectively, and for the detection of

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... Z Catheter Angiography Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material ... vessels in the body. Angiography is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging ( ...

  19. Contrast-enhanced MR angiography of abdominal vessels: Is there still a role for angiography?

    Energy Technology Data Exchange (ETDEWEB)

    Vosshenrich, R.; Fischer, U. [Department of Radiology, Georg-August-Universitaet Goettingen (Germany)

    2002-01-01

    The purpose of this review article is to describe recent advantages in contrast-enhanced (CE) three-dimensional (3D) magnetic resonance angiography (MRA) in comparison with other vascular imaging techniques, and to discuss their current clinical applications for the imaging of abdominal vessels. Principles and technical considerations are presented and clinical applications are reviewed for different vascular diseases. In ruptured aortic aneurysms and acute dissections CT is the method of first choice. Contrast-enhanced 3D MRA can be well used for therapeutic planning and follow-up in patients with stable disease. A comprehensive MR examination including CE 3D MRA, MR urography and MR nephrogram has the potential to replace the conventional studies for the evaluation of renal vascular disease. It is an accurate method for imaging the origins of coeliac and superior mesenteric arteries, although the image resolution is too low for reliable assessment of the inferior mesenteric artery. Contrast-enhanced 3D MRA has emerged as the method of choice for studying the portal venous system in liver transplant recipients, in patients with portal hypertension and in cases with abdominal tumours for preoperative evaluation. Additional non-invasive flow measurements are useful in monitoring portal hypertension. The abdominal veins can be well imaged using unenhanced MR techniques. Imaging may be facilitated with intravascular contrast media. Contrast-enhanced 3D MRA can replace intra-arterial DSA for diagnosis, therapy planning and follow-up in patients with abdominal vascular disease. Catheter-based arteriography will still be used for interventional procedures such as percutaneous transluminal angioplasty, stent placement and embolisation. (orig.)

  20. CT coronary angiography vs. invasive coronary angiography in CHD

    Directory of Open Access Journals (Sweden)

    Anja Hagen

    2012-04-01

    Full Text Available Scientific background: Various diagnostic tests including conventional invasive coronary angiography and non-invasive computed tomography (CT coronary angiography are used in the diagnosis of coronary heart disease (CHD. Research questions: The present report aims to evaluate the clinical efficacy, diagnostic accuracy, prognostic value cost-effectiveness as well as the ethical, social and legal implications of CT coronary angiography versus invasive coronary angiography in the diagnosis of CHD. Methods: A systematic literature search was conducted in electronic data bases (MEDLINE, EMBASE etc. in October 2010 and was completed with a manual search. The literature search was restricted to articles published from 2006 in German or English. Two independent reviewers were involved in the selection of the relevant publications. The medical evaluation was based on systematic reviews of diagnostic studies with invasive coronary angiography as the reference standard and on diagnostic studies with intracoronary pressure measurement as the reference standard. Study results were combined in a meta-analysis with 95 % confidence intervals (CI. Additionally, data on radiation doses from current non-systematic reviews were taken into account. A health economic evaluation was performed by modelling from the social perspective with clinical assumptions derived from the meta-analysis and economic assumptions derived from contemporary German sources. Data on special indications (bypass or in-stent-restenosis were not included in the evaluation. Only data obtained using CT scanners with at least 64 slices were considered. Results: No studies were found regarding the clinical efficacy or prognostic value of CT coronary angiography versus conventional invasive coronary angiography in the diagnosis of CHD. Overall, 15 systematic reviews with data from 44 diagnostic studies using invasive coronary angiography as the reference standard (identification of obstructive

  1. Unusual Congenital Aortic Anomaly with Rare Common Celiamesenteric Trunk Variation: MR Angiography and Digital Substraction Angiography Findings

    International Nuclear Information System (INIS)

    Tosun, Ozgur; Sanlidilek, Umman; Cetin, Huseyin; Ozdemir, Ozcan; Kurt, Aydin; Sakarya, Mehmet Emin; Tas, Ismet

    2007-01-01

    Magnetic resonance angiography and digital substraction angiography (DSA) findings in a case with a rare congenital thoracoabdominal aortic hypoplasia and common celiamesenteric trunk variation with occlusion of infrarenal abdominal aorta are described here. To our knowledge, this aortic anomaly has not been previously described in the English literature. DSA is the optimum imaging modality for determination of aortic hypoplasia, associated vascular malformations, collateral vessels, and direction of flow within vessels

  2. Comparison of two-dimensional MR angiography and microsphere measurement of renal blood flow for detection of renal artery stenosis

    International Nuclear Information System (INIS)

    Powers, T.A.; Lorenz, C.H.; Shetty, A.N.; Holburn, G.E.; Price, R.R.

    1990-01-01

    This paper compares depiction of the renal arteries by MR angiography to renal blood flow as determined with microspheres in a dog model of renal artery stenosis. A left renal artery stenosis was created by placement of a silk ligature. Nb-95-labeled microspheres were injected into the left ventricle and a reference blood sample was drawn. The dog was imaged in the 1.5-T MR imager with two-dimensional MR angiography sequences. The kidneys were excised, weighted, divided into sections, and counted. Two dogs were studied to date. In dog 1, left renal blood flow (RBF) was 42 mL/min/100 g and right RBF was 337 mL/min/100 g. In dog 2 left RBF was 44 mL/min/100 g and right RBF was 608 mL/min/100 g

  3. Assessment of the signal intensity distribution pattern within the unruptured cerebral aneurysms using color-coded 3D MR angiography

    International Nuclear Information System (INIS)

    Satoh, Toru; Omi, Megumi; Ohsako, Chika

    2005-01-01

    To evaluate the interaction between the MR signal intensity distribution pattern and bleb formation/deformation of the aneurysmal dome, fifty cases of the unruptured cerebral aneurysms were investigated with the color-coded 3D MR angiography. Patterns were categorized into central-type, neck-type and peripheral-type according to the distribution of MR signals with low-, moderate- and high signal intensity areas. Imaging analysis revealed the significant relationship (P<0.02) of the peripheral-type aneurysms to the bleb formation and deformation of the dome, compared with those of central- and neck-type. Additionally, peripheral-type signal intensity distribution pattern was shown with aneurysms harboring relatively large dome size and lateral-type growth including internal carotid aneurysms. Prospective analysis of intraaneurysmal flow pattern with the color-coded 3D MR angiography may provide patient-specific analysis of intraaneurysmal flow status in relation to the morphological change of the corresponding aneurysmal dome in the management of unruptured cerebral aneurysms. (author)

  4. MR-angiography in vasculitis and benign angiopathy of the central nervous system

    International Nuclear Information System (INIS)

    Schlueter, A.; Hirsch, W.; Jassoy, A.; Behrmann, C.; Spielmann, R.P.; Kornhuber, M.; Keysser, G.

    2001-01-01

    To evaluate TOF 3D magnetic resonance angiography (MRA) of the intracranial arteries in patients with vasculitis or vasculitis-like benign angiopathy of the central nervous system (CNS). Method: The results of MRA in 20 patients with clinically and radiographically proven vasculitis (17/20) or vasculitis-like benign angiopathy (3/20) of the CNS were retrospectively analysed. Patients with hyperintense lesions of more than 3 mm on T 2 -weighted MRI images were included in this trial. An inflammatory, embolic, neurodegenerative or metastatic origin of these lesions was excluded by extensive clinical studies. For the MR-examination a TOF 3D FISP sequence was used on a 1.5 T imager. Results: MRA showed characteristic changes for vasculitis or angiopathy in 15 of 20 patients (75%). Conclusions: In patients suspected of having a vasculitis or vasculitis-like angiopathy, MRA is recommended as a non-invasive modality. If the results of MRI and extensive clinical studies are carefully correlated, MRA may substitute conventional angiography in cases with typical vascular changes. (orig.) [de

  5. Anomalous vessel in the middle ear: the role of CT and MR angiography

    International Nuclear Information System (INIS)

    Caldas, J.G.M.P.; Iffenecker, C.; Lasjaunias, P.; Doyon, D.; Attal, P.

    1998-01-01

    An 8-year-old child was examined because of conductive hearing loss with a retrotympanic mass on otoscopy. CT and MR angiography showed a large inferior tympanic artery traversing the hypotympanum and joining a thin, irregular internal carotid artery with a normal middle meningeal artery. These investigations, coupled with knowledge of the embryological development allowed a diagnosis of a complex vascular anomaly in the middle ear and avoided potential surgical complications. (orig.)

  6. Conventional and CT angiography in children: dosimetry and dose comparisons

    International Nuclear Information System (INIS)

    Frush, Donald P.; Yoshizumi, Terry

    2006-01-01

    Tremendous advances have been made in imaging in children with both congenital and acquired heart disease. These include technical advances in cardiac catheterization and conventional angiography, especially with advancements in interventional procedures, as well as noninvasive imaging with MR and CT angiography. With rapid advances in multidetector CT (MDCT) technology, most recently 64-detector array systems (64-slice MDCT), have come a number of advantages over MR. However, both conventional and CT angiography impart radiation dose to children. Although the presence of radiation exposure to children has long been recognized, it is apparent that our ability to assess this dose, particularly in light of the rapid advancements, has been limited. Traditional methods of dosimetry for both conventional and CT angiography are somewhat cumbersome or involve a potential for substantial uncertainty. Recent developments in dosimetry, including metal oxide semiconductor field effect transistors (MOSFET) and the availability of anthropomorphic, tissue-equivalent phantoms have provided new opportunities for dosimetric assessments. Recent work with this technology in state-of-the-art cardiac angiography suites as well as with MDCT have offered direct comparisons of doses in infants and children undergoing diagnostic cardiac evaluation. It is with these dose data that assessment of risks, and ultimately the assessment of risk-benefit, can be better achieved. (orig.)

  7. Multidetector-row CT angiography of hepatic artery: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Jeong, Yong Yeon; Yoon, Woong; Kim, Jae Kyu; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun

    2003-01-01

    To determine the usefulness of three-dimensional CT angiography using multidetector-row CT (MD-CT) for delineating the arterial anatomy of the liver. Hepatic arterial three-dimensional CT angiography was performed using MDCT (lightspeed Qx/I; GE medical systems, milwaukee, Wis., U.S.A.) in 45 patients with HCC undergoing conventional angiography for transcatheter hepatic arterial chemoembolization. The scanning parameters during the early arterial phase were 2.5 mm slice thickness, 7.5 mm rotation of table speed, and a pitch of 3. Images were obtained by one radiologist using maximum intensity projection from axial CT images obtained during the early arterial phase. Two radiologists blinded to the findings of conventional angiography independently evaluated the hepatic arterial anatomy and the quality of the images obtained. Compared with conventional angiography, reader A correctly evaluated the hepatic arterial anatomy depicted at three-dimensional CT angiography. Reader B's evaluation was correct in 40 of 45 patients. Interobserver agreement was good (kappa value, 0.73), and both readers assessed the quality of three-dimensional CT angiography as excellent. Three-dimensional CT angiography using MDCT was accurate for delineating the arterial anatomy of the liver, and interobserver agreement was good. The modality may provide, prior to conventional angiography, valuable information regrading a patient's hepatic arterial anatomy

  8. Three-dimensional black blood MR angiography of the liver during breath holding. A comparison with two-dimensional time-of-flight MR angiography

    International Nuclear Information System (INIS)

    Suto, Y.; Ohuchi, Y.; Kimura, T.; Shirakawa, T.; Mizuuchi, N.; Takizawa, O.; Yamane, T.; Kamba, M.; Moriyama, S.; Ohta, Y.

    1994-01-01

    In 2-D time-of-flight MR angiography (2-D TOF MRA) of the liver, artifacts caused by respiratory motion are unavoidable. Therefore, a 3-D black blood MRA of the liver was attempted in 7 healthy volunteers, using a 3-D gradient echo sequence which allows imaging during breath holding. 2-D TOF MRA was performed as well. In all subjects, 3-D MRA allowed visualization of the trunk, 1st-, and 2nd-order branches of the portal vein without interruption. Right 3rd-order branches were visualized without interruption in 6 of 7 subjects (85%). However, with 2-D MRA, the transverse portion of the left main portal vein could not be visualized in any subject, and the periphery of the portal vein was less clear than with 3-D MRA. (orig.)

  9. Application of MR digital subtraction angiography to the diagnosis of cerebral arteriovenous malformations

    International Nuclear Information System (INIS)

    Katase, Shichiro; Tsuchiya, Kazuhiro; Osawa, Ayako; Hachiya, Junichi

    2000-01-01

    We evaluated the utility of MR DSA using rapid thick-section T1-weighted imaging and bolus injections of gadolinium to diagnose cerebral arteriovenous malformations (AVMs). We reviewed MR DSA images obtained from 16 patients (9 men and 7 women; average age, 35.8 years). Anatomic depictions of each component of the AVMs were rated using a four-point grade scale and compared with conventional and/or MR angiograms. We were able to obtain serial images demonstrating passage of gadolinium through the AVM. The average scores for feeders, nidus, and drainers was 1.4, 2.2, and 1.8, respectively with the overall average of 2.1. The MR DSA technique that we have developed presently has limited value in depicting the anatomic details of cerebral AVMs. However, we believe that MR DSA is valuable and should be used in addition to conventional MR imaging and angiography in patients with cerebral AVM at the time of their initial diagnosis and during follow-up after therapy. (author)

  10. MRI and MR angiography of persistent trigeminal artery

    International Nuclear Information System (INIS)

    Piotin, M.; Miralbes, S.; Cattin, F.; Marchal, H.; Amor-Sahli, M.; Moulin, T.; Bonneville, J.F.

    1996-01-01

    We describe the MRA and MR angiography (MRA) features of persistent trigeminal artery (PTA) found incidentally in eight patients, with special attention to its origin, site and course. The different patterns of posterior communicating arteries were also noted. The PTA were shown on sagittal, coronal and axial MRI and on MRA. In four cases, the PTA arose from the lateral aspect of the intracavernous internal carotid artery, ran caudally, passing round the bottom of the dorsum sellae to join the basilar artery. In the other four cases, it arose from the medial aspect, ran caudally through the sella turcica and pierced the dorsum sellae to join the basilar artery. The posterior communicating arteries were present unilaterally in five cases and bilaterally in one, and absent bilaterally in two. Identification of a PTA with a trans-sellar course is crucial if a trans-sphenoidal surgery is planned. (orig.). With 3 figs

  11. Imaging of the digital arteries: Digital subtraction angiography versus conventional angiography

    International Nuclear Information System (INIS)

    Menanteau, B.P.; Treutenaere, J.M.; Marcus, C.; Ladam, V.; Gausserand, F.

    1986-01-01

    The authors report their experience with the use of digital subtraction angiography (DSA) and conventional angiography of the hand. Of the 95 patients in the study group, 80 underwent conventional angiography and 15 underwent DSA. They analyzed the studies with regard to the type and amount of contrast agent used, the number of radiographs needed, and the diagnostic quality of the images. Conventional angiography often requires general anesthesia, magnification, and pharmaco-angiographic techniques to improve the image-based diagnosis. In comparison with conventional angiography, intraarterial DSA is characterized by improved contrast sensitivity and inferior spatial resolution. However, DSA provides images as acceptable as those of conventional angiography. Smaller catheters can be used, and the examination is performed under local anesthesia. The authors conclude that intraarterial DSA is now the technique of choice for examining patients with chronic ischemia of the hand

  12. MR-angiography in vasculitis and benign angiopathy of the central nervous system; MR-Angiographie in der Diagnostik von Vaskulitiden und benignen Angiopathien des Zentralnervensystems

    Energy Technology Data Exchange (ETDEWEB)

    Schlueter, A.; Hirsch, W.; Jassoy, A.; Behrmann, C.; Spielmann, R.P. [Klinik fuer Diagnostische Radiologie, Martin-Luther-Univ. Halle-Wittenberg (Germany); Kornhuber, M. [Klinik fuer Neurologie, Martin-Luther-Univ. Halle-Wittenberg (Germany); Keysser, G. [Klinik fuer Innere Medizin I, Martin-Luther-Univ. Halle-Wittenberg (Germany)

    2001-06-01

    To evaluate TOF 3D magnetic resonance angiography (MRA) of the intracranial arteries in patients with vasculitis or vasculitis-like benign angiopathy of the central nervous system (CNS). Method: The results of MRA in 20 patients with clinically and radiographically proven vasculitis (17/20) or vasculitis-like benign angiopathy (3/20) of the CNS were retrospectively analysed. Patients with hyperintense lesions of more than 3 mm on T{sub 2}-weighted MRI images were included in this trial. An inflammatory, embolic, neurodegenerative or metastatic origin of these lesions was excluded by extensive clinical studies. For the MR-examination a TOF 3D FISP sequence was used on a 1.5 T imager. Results: MRA showed characteristic changes for vasculitis or angiopathy in 15 of 20 patients (75%). Conclusions: In patients suspected of having a vasculitis or vasculitis-like angiopathy, MRA is recommended as a non-invasive modality. If the results of MRI and extensive clinical studies are carefully correlated, MRA may substitute conventional angiography in cases with typical vascular changes. (orig.) [German] Ziel der Studie war es, den Wert der TOF 3D Magnetresonanzangiographie (MRA) bei Patienten mit Vaskulitis oder vaskulitisaehnlichen, benignen Angiopathien des Zentralnervensystems (ZNS) zu erfassen. Methoden: Die MRA-Aufnahmen von 20 Patienten mit klinisch und bildgebend nachgewiesener Vaskulitis (17/20) oder vaskulitisaehnlicher, benigner Angiopathie (3/20) des ZNS wurden retrospektiv ausgewertet. Eingeschlossen wurden Patienten mit Laesionen des Hirnparenchymsgroessen 3 mm in den T{sub 2}-gewichteten Sequenzen der MRT, wobei diese Veraenderungen aufgrund umfangreicher klinischer Untersuchungen nicht auf das Vorliegen neurodegenerativer, anderweitig entzuendlicher, metastatischer oder embolischer Ursachen zurueckzufuehren waren. Fuer die MRA wurde eine TOF 3D FISP-Sequenz auf einem 1,5T MR-Geraet verwendet. Ergebnisse: MR-angiographisch wurden bei 15/20 Patienten (75

  13. Whole-heart MR coronary angiography - first results

    International Nuclear Information System (INIS)

    Ozgun, M.; Quante, M.; Fischbach, R.; Heindel, W.; Maintz, D.; Hoffmeier, A.; Botnar, R.

    2006-01-01

    Purpose: To evaluate a new coronary MR angiography technique covering the whole coronary artery tree in one data set acquisition. Materials and methods: Six healthy volunteers and 15 patients with known CAD were examined with a navigator gated and corrected (NAV) free-breathing 3D steady-state free precession sequence covering the whole heart (WH-MRA) (TR=5.4, TE-2.7, SENSE factor=2, 160 slices, 0.75 mm reconstructed slice thickness, in-plane resolution =0.99 x 0.99 mm 2 , scan time 14 min [50% NAV efficiency]) and a vessel targeted 3D SSFP MRA sequence (t-MRA) (TR=5.6 ms, TE-2.8 ms, 20 slices of 1.5 mm reconstructed slice thickness, in-plane resolution =0.99 x 0.99 mm 2 , scan time=7 min [50% NAV efficiency]). Subjective image quality (4-point scale) and objective image quality parameters including vessel sharpness, vessel diameter and CNR were calculated for WH-MRA and t-MRA. In patients, the accuracy for detection of stenosis larger than 50% was compared to the accuracy of X-ray coronary angiography (XA), which was considered the standard. Results: WH-MRA demonstrated good vessel visibility in healthy subjects (100%) whereas vessel visibility in patients was limited (78% in an 8 segment evaluation). Vessel sharpness was inferior to that of t-MRA in patients (37 vs. 42%) but equal in healthy subjects (42%). Vessel diameter did not differ significantly between WH-MRA and t-MRA. CNR was significantly reduced for WH-MRA (CNR 7.4 vs. 11.5). The diagnostic accuracy for the detection of CAD was comparable for both MRA approaches (85.5 vs. 86.2%). Conclusion: WH-MRA allows good coronary artery visualization in healthy subjects and patients and provides a simplified scanning procedure and advantages in 3D post-processing. Regarding image parameters and the detection of CAD, the results are comparable to those acquired with t-MRA. The major disadvantage remains the high number of diagnostically insufficient images. (orig.)

  14. Renal MR angiography and perfusion in the pig using hyperpolarized water.

    Science.gov (United States)

    Wigh Lipsø, Kasper; Hansen, Esben Søvsø Szocska; Tougaard, Rasmus Stilling; Laustsen, Christoffer; Ardenkjaer-Larsen, Jan Henrik

    2017-09-01

    To study hyperpolarized water as an angiography and perfusion tracer in a large animal model. Protons dissolved in deuterium oxide (D 2 O) were hyperpolarized in a SPINlab dissolution dynamic nuclear polarization (dDNP) polarizer and subsequently investigated in vivo in a pig model at 3 Tesla (T). Approximately 15 mL of hyperpolarized water was injected in the renal artery by hand over 4-5 s. A liquid state polarization of 5.3 ± 0.9% of 3.8 M protons in 15 mL of deuterium oxide was achieved with a T 1 of 24 ± 1 s. This allowed injection through an arterial catheter into the renal artery and subsequently high-contrast imaging of the entire kidney parenchyma over several seconds. The dynamic images allow quantification of tissue perfusion, with a mean cortical perfusion of 504 ± 123 mL/100 mL/min. Hyperpolarized water MR imaging was successfully demonstrated as a renal angiography and perfusion method. Quantitative perfusion maps of the kidney were obtained in agreement with literature and control experiments with gadolinium contrast. Magn Reson Med 78:1131-1135, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  15. Evaluation of MR angiography and blood flow measurement in abdominal and peripheral arterial occlusive disease

    Energy Technology Data Exchange (ETDEWEB)

    Tabuchi, Kenji [Dokkyo Univ. School of Medicine, Mibu, Tochigi (Japan)

    2000-03-01

    To assess the characteristics of blood flow measurement with MR Angiography (MRA) to evaluate the status of vascular stenoses, two or three dimensional time-of-flight MRA and velocity-encoded cine MR were performed in the 230 segments of 35 patients, with abdominal and peripheral arterial occlusive diseases. In 11 of these 35 patients digital subtraction angiography was additionally underwent, and the stenotic findings was compared with MRA. There were 17 segments in which the velocity could not be measured, because the blood flow exceeded the upper limit of peak-encoded velocity (VENC) which was set at 120 cm/sec. Therefore, it is necessary to set the upper limit of VENC at higher than 120 cm/sec. There were 11 stenotic findings in DSA and 20 stenotic findings in MRA. Pulsatility Index (PI=(max velocity-min. velocity)/average velocity) were used for evaluating the blood flow waveform, and there were significant difference between the 11 stenotic findings of DSA and the others'. In summery, MRA was considered as useful examination to assess the degree of the vascular stenoses in abdominal and peripheral arterial occlusive disease. (author)

  16. Peripheral Vasculature: High-Temporal- and High-Spatial-Resolution Three-dimensional Contrast-enhanced MR Angiography1

    Science.gov (United States)

    Haider, Clifton R.; Glockner, James F.; Stanson, Anthony W.; Riederer, Stephen J.

    2009-01-01

    Purpose: To prospectively evaluate the feasibility of performing high-spatial-resolution (1-mm isotropic) time-resolved three-dimensional (3D) contrast material–enhanced magnetic resonance (MR) angiography of the peripheral vasculature with Cartesian acquisition with projection-reconstruction–like sampling (CAPR) and eightfold accelerated two-dimensional (2D) sensitivity encoding (SENSE). Materials and Methods: All studies were approved by the institutional review board and were HIPAA compliant; written informed consent was obtained from all participants. There were 13 volunteers (mean age, 41.9; range, 27–53 years). The CAPR sequence was adapted to provide 1-mm isotropic spatial resolution and a 5-second frame time. Use of different receiver coil element sizes for those placed on the anterior-to-posterior versus left-to-right sides of the field of view reduced signal-to-noise ratio loss due to acceleration. Results from eight volunteers were rated independently by two radiologists according to prominence of artifact, arterial to venous separation, vessel sharpness, continuity of arterial signal intensity in major arteries (anterior and posterior tibial, peroneal), demarcation of origin of major arteries, and overall diagnostic image quality. MR angiographic results in two patients with peripheral vascular disease were compared with their results at computed tomographic angiography. Results: The sequence exhibited no image artifact adversely affecting diagnostic image quality. Temporal resolution was evaluated to be sufficient in all cases, even with known rapid arterial to venous transit. The vessels were graded to have excellent sharpness, continuity, and demarcation of the origins of the major arteries. Distal muscular branches and the communicating and perforating arteries were routinely seen. Excellent diagnostic quality rating was given for 15 (94%) of 16 evaluations. Conclusion: The feasibility of performing high-diagnostic-quality time-resolved 3D

  17. Preoperative cerebral aneurysm assessment by three-dimensional CT angiography. Feasibility of surgery without cerebral angiography

    International Nuclear Information System (INIS)

    Kashiwagi, Shiro; Yamashita, Katsuhiro; Kato, Shoichi; Ito, Haruhide; Kurokawa, Kensuke; Watanabe, Yutaka

    1999-01-01

    The purpose of this study is to assess the capability of three-dimensional CT angiography (3D-CTA) to replace conventional catheter angiography as a preoperative examination for unruptured intracranial aneurysms. A prospective study was designed to evaluate 18 patients with 20 unruptured intracranial aneurysms (13 middle cerebral artery aneurysms, 6 anterior communicating artery aneurysms, and 1 internal carotid posterior communicating artery aneurysm) who underwent surgery. There were 12 women and 6 men with the average age of 63 years old. All patients were initially diagnosed as having intracranial aneurysms by MR angiography, followed by 3D-CTA and conventional catheter angiography for confirmation. Three experienced neurosurgeons were in charge of the operations. One of the neurosurgeons (surgeon 1) was provided with only 3D-CTA as the preoperative radiological evaluation, while the others (surgeon 2 and 3) were given through assessments with MRA, 3D-CTA, and conventional angiography. Surgeon 1 carried out the operations under careful observation by the surgeons 2 and 3. Problems encountered by the surgeon 1 during surgery were recorded. Neck clipping in 19 aneurysms and dome wrapping in 1 were successfully accomplished. All patients were discharged without complication. Surgeries went smoothly in 16 aneurysms with 3D-CTA alone. Discrepancies between the 3D-CTA findings and microsurgical anatomy were noted in 4 aneurysms: the size of the neck was overestimated in 3 aneurysms, the relationships to parent arteries were obscure in 2 aneurysms, and a perforating artery problematic to neck clipping was missed in 1 aneurysms by 3D-CTA. The results of this study support the notion that 3D-CTA can replace conventional catheter angiography as preoperative examination in the majority of regular-sized anterior circulation aneurysms. Nevertheless, surgeons should recognize and be prepared for the fact that 3D-CTA can give false impression about the aneurysm neck and

  18. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography ...

  19. Magnetic resonance angiography (MRA)

    International Nuclear Information System (INIS)

    Arlart, I.P.; Guhl, L.

    1992-01-01

    An account is given in this paper of the physical and technical principles underlying the 'time-of-flight' technique for imaging of vessels by magnetic resonance tomography. Major indications for the new procedure of magnetic resonance angiography at present are intracerebral and extracerebral vessels, with digital subtraction angiography quite often being required to cope with minor alterations (small aneurysms, small occlusions). Magnetic resonance angiography and digital subtraction angiography are compared to each other for advantages and disadvantages. Basically, replacement of radiological angiography by magnetic resonance angiography appears to be possible only within limits, since X-ray diagnostics primarily provides morphological information about vessels, whereas flow dynamics is visualized by the 'time-of-flight' technique. (orig.) [de

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you're taking and allergies, especially ... is Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... far outweighs the risk. If you have a history of allergy to x-ray contrast material, your ... Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. Angiography uses ... has narrowed the arteries to the legs and help prepare for endovascular intervention or surgery. detect disease ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... resonance imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an ... The catheter used in angiography is a long plastic tube about as thick as a strand of ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... lies. The catheter used in angiography is a long plastic tube about as thick as a strand of spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Interventional radiologist performing an angiography exam View ... ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored by Please note ...

  6. Diagnosis of occlusive arterial disease and assessment of IVR with fat-suppressed gadolinium-enhanced three-dimensional MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Amano, Yasuo; Gemma, Kazuhito; Kawamata, Hiroshi; Okajima, Yuhji; Watari, Jun; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan); Maki, Toshio; Tsuchihashi, Toshio

    1996-10-01

    Fat-suppressed gadolinium-enhanced three-dimensional MR angiography (FS-CE-3D-MRA) was performed to make a diagnosis of occlusive arterial disease and evaluate the effectiveness of IVR treatment for it. FS-CE-3D-MRA delineated stenosis of common iliac arteries, which was confirmed by X-ray angiography. FS-CE-3D-MRA also detected ulcerated plaque and arterial wall irregularity. The effectiveness of IVR as atherectomy and stent placement was accurately assessed with FS-CE-3D-MRA. FS-CE-3D-MRA was useful in evaluating occlusive arterial disease with short examination times and high spatial resolution, although iliac circumflexial arteries were not detected by this technique. (author)

  7. Renal contrast-enhanced MR angiography: timing errors and accurate depiction of renal artery origins.

    Science.gov (United States)

    Schmidt, Maria A; Morgan, Robert

    2008-10-01

    To investigate bolus timing artifacts that impair depiction of renal arteries at contrast material-enhanced magnetic resonance (MR) angiography and to determine the effect of contrast agent infusion rates on artifact generation. Renal contrast-enhanced MR angiography was simulated for a variety of infusion schemes, assuming both correct and incorrect timing between data acquisition and contrast agent injection. In addition, the ethics committee approved the retrospective evaluation of clinical breath-hold renal contrast-enhanced MR angiographic studies obtained with automated detection of contrast agent arrival. Twenty-two studies were evaluated for their ability to depict the origin of renal arteries in patent vessels and for any signs of timing errors. Simulations showed that a completely artifactual stenosis or an artifactual overestimation of an existing stenosis at the renal artery origin can be caused by timing errors of the order of 5 seconds in examinations performed with contrast agent infusion rates compatible with or higher than those of hand injections. Lower infusion rates make the studies more likely to accurately depict the origin of the renal arteries. In approximately one-third of all clinical examinations, different contrast agent uptake rates were detected on the left and right sides of the body, and thus allowed us to confirm that it is often impossible to optimize depiction of both renal arteries. In three renal arteries, a signal void was found at the origin in a patent vessel, and delayed contrast agent arrival was confirmed. Computer simulations and clinical examinations showed that timing errors impair the accurate depiction of renal artery origins. (c) RSNA, 2008.

  8. Pancreatic adenocarcinoma: combination of MR imaging, MR angiography and MR cholangiopancreatography for the diagnosis and assessment of resectability

    International Nuclear Information System (INIS)

    Catalano, C.; Pavone, P.; Laghi, A.; Panebianco, V.; Scipioni, A.; Fanelli, F.; Brillo, R.; Passariello, R.

    1998-01-01

    The purpose of this study was to determine the possibility of integrating MR cholangiopancreatography (MRCP) and MR angiography (MRA) to conventional MR images in the diagnosis and assessment of resectability of pancreatic adenocarcinoma. Twenty-three patients with pancreatic adenocarcinoma were prospectively examined with MR. Conventional MR images were acquired in all patients. Three-dimensional MRCP and MRA images were acquired in all patients with suspected biliary and vascular involvement. Acquisition time was less than 45 min in all cases. Images were independently evaluated by two radiologists, with final reading decided by consensus among readers. Diagnosis was confirmed with surgery in 16 patients and with percutaneous biopsy in 7. Concordance among readers was high with a kappa value of 0.83. Pancreatic adenocarcinoma was observed in all patients. Correct assessment of unresectability due to vascular involvement was found in 22 of 23 patients. Biliary obstruction was evident in 13 patients, involving the biliary and pancreatic ducts in 9 and the biliary ducts only in 4. Technical advances permit extensive use of MRI in the evaluation of abdominal pathologies. The combination of MR imaging, MRCP, and MRA can provide sufficient information for the diagnosis and assessment of resectability of pancreatic adenocarcinoma, which otherwise would require three different exams. (orig.)

  9. Magnetic resonance angiography vs. angiography in tetralogy of Fallot.

    Science.gov (United States)

    Rao, Uppalapati Venkateswara; Vanajakshamma, Velam; Rajasekhar, Durgaprasad; Lakshmi, Amancharla Yadagiri; Reddy, Reddivari Niranjan

    2013-08-01

    : To determine whether gadolinium-enhanced three-dimensional magnetic resonance angiography can provide a noninvasive alternative to diagnostic catheterization for evaluation of pulmonary artery anatomy in tetralogy of Fallot. Thirty-five consecutive patients with tetralogy of Fallot, who attended the cardiology outpatient department between January 2008 and December 2009, were included in the study. There were 21 males and 14 females, with a mean age of 9 ± 4.15 years (range, 3-21 years). Thirty-two patients had tetralogy of Fallot with varying severities of valvular and infundibular stenosis. Three patients had tetralogy of Fallot with pulmonary atresia. All patients underwent both cardiac catheterization with X-ray angiography and 3-dimensional magnetic resonance angiography within one month. Measurements of right and left pulmonary arteries and aortopulmonary collaterals were equal by both methods. There was a good correlation between magnetic resonance angiography and catheterization measurements of branch pulmonary arteries. Gadolinium-enhanced three-dimensional magnetic resonance angiography can be used as a reliable noninvasive alternative to X-ray cineangiography for delineation of pulmonary arterial anatomy in sick infants and young children, obviating the need for catheterization.

  10. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. ...

  11. Coronary Artery Anomalies and Variants: Technical Feasibility of Assessment with Coronary MR Angiography at 3 T1

    Science.gov (United States)

    Gharib, Ahmed M.; Ho, Vincent B.; Rosing, Douglas R.; Herzka, Daniel A.; Stuber, Matthias; Arai, Andrew E.; Pettigrew, Roderic I.

    2008-01-01

    The purpose of this study was to prospectively use a whole-heart three-dimensional (3D) coronary magnetic resonance (MR) angiography technique specifically adapted for use at 3 T and a parallel imaging technique (sensitivity encoding) to evaluate coronary arterial anomalies and variants (CAAV). This HIPAA-compliant study was approved by the local institutional review board, and informed consent was obtained from all participants. Twenty-two participants (11 men, 11 women; age range, 18–62 years) were included. Ten participants were healthy volunteers, whereas 12 participants were patients suspected of having CAAV. Coronary MR angiography was performed with a 3-T MR imager. A 3D free-breathing navigator-gated and vector electrocardiographically–gated segmented k-space gradient-echo sequence with adiabatic T2 preparation pulse and parallel imaging (sensitivity encoding) was used. Whole-heart acquisitions (repetition time msec/echo time msec, 4/1.35; 20° flip angle; 1 × 1 × 2-mm acquired voxel size) lasted 10–12 minutes. Mean examination time was 41 minutes ± 14 (standard deviation). Findings included aneurysms, ectasia, arteriovenous fistulas, and anomalous origins. The 3D whole-heart acquisitions developed for use with 3 T are feasible for use in the assessment of CAAV. © RSNA, 2008 PMID:18372470

  12. MR angiography in tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Kalita, Jayantee; Prasad, Sreeram; Maurya, Pradeep K.; Misra, Usha K. (Dept. of Neurology, Sanjay Gandhi Post Graduate Inst. of Medical Sciences, Lucknow (India)), Email: drukmisra@rediffmail.com; Kumar, Sunil (Dept. of Radiodiagnosis, Sanjay Gandhi Post Graduate Inst. of Medical Sciences, Lucknow (India))

    2012-04-15

    Background: Infarctions in tuberculous meningitis (TBM) are common but there is a paucity of studies on MR angiography (MRA). Purpose: To evaluate the pattern and predictors of MRA abnormality in patients with TBM. Material and Methods: Sixty-seven patients with TBM were subjected to clinical, laboratory, magnetic resonance imaging (MRI), and MRA evaluation. The severity of meningitis, focal deficit, CSF findings, and stroke co-morbidities were recorded. Presence of exudates, infarction, hydrocephalous, and tuberculoma on MRI were noted. On intracranial MRA, occlusion or more than 50% narrowing of proximal middle cerebral artery (MCA), anterior cerebral artery (ACA) and posterior cerebral artery (PCA), and basilar artery were considered abnormal. The MRA abnormality was correlated with clinical, laboratory, and MRI findings. Results: Sixty-seven patients, aged 3-75 years (median 34 years) were included. MRI was abnormal in 61 (91%) patients; basal exudates in 24, hydrocephalous in 23, tuberculoma in 33, and infarction in 40. MRA was abnormal in 34 (50.7%); MCA was most commonly involved (n = 21), followed by PCA (n = 14), ICA (n = 8), ACA (n 5), basilar artery (n = 5), and vertebral and superior cerebellar artery (1 each). One-fourth of the patients had abnormality in both anterior and posterior circulations. MRA abnormality was related to hydrocephalous and infarction; corresponding infarct was present in 61.8% patients; 41.7% patients with abnormal MRA developed infarct at 3 months but none with normal MRA. Conclusion: Half the patients with TBM had MRA abnormality involving both anterior and posterior circulations and 61.8% of them had corresponding infarcts

  13. Magnetic Resonance Imaging and Angiography for the Prerupture Diagnosis of Rudimentary Uterine Horn Pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Ozeren, S.; Caliskan, E.; Corakci, A.; Ozkan, S.; Demirci, A. [Kocaeli Univ., Faculty of Medicine, Kocaeli (Turkey). Dept. of Obstetrics and Gynecology

    2004-12-01

    Magnetic resonance (MR) imaging and MR angiography were used for the differential diagnosis and preoperative planning of a 17 weeks of age rudimentary horn pregnancy. A 26-year-old primigravida was referred to our hospital with a preliminary diagnosis of abdominal pregnancy. After an inconclusive ultrasound evaluation we were able to identify a rudimentary horn pregnancy, extent of the placental invasion, and the vascular supply via MR imaging and time of flight sequence MR angiography. The obtained data were also used for preoperative planning, which resulted in an uncomplicated, prerupture laparotomy for pregnancy termination and a healthy female.

  14. Fusion of magnetic resonance angiography and magnetic resonance imaging for surgical planning for meningioma. Technical note

    International Nuclear Information System (INIS)

    Kashimura, Hiroshi; Ogasawara, Kuniaki; Arai, Hiroshi

    2008-01-01

    A fusion technique for magnetic resonance (MR) angiography and MR imaging was developed to help assess the peritumoral angioarchitecture during surgical planning for meningioma. Three-dimensional time-of-flight (3D-TOF) and 3D-spoiled gradient recalled (SPGR) datasets were obtained from 10 patients with intracranial meningioma, and fused using newly developed volume registration and visualization software. Maximum intensity projection (MIP) images from 3D-TOF MR angiography and axial SPGR MR imaging were displayed at the same time on the monitor. Selecting a vessel on the real-time MIP image indicated the corresponding points on the axial image automatically. Fusion images showed displacement of the anterior cerebral or middle cerebral artery in 7 patients and encasement of the anterior cerebral arteries in I patient, with no relationship between the main arterial trunk and tumor in 2 patients. Fusion of MR angiography and MR imaging can clarify relationships between the intracranial vasculature and meningioma, and may be helpful for surgical planning for meningioma. (author)

  15. Detection of aneurysms in subarachnoidal hemorrhage - CT-angiography versus digital subtraction angiography

    International Nuclear Information System (INIS)

    Roehnert, W.; Haenig, V.; Hietschold, V.; Abolmaali, N.

    1998-01-01

    Purpose: The value of CT-angiography (CT-A) for the visualization of intracranial aneurysms was more closely defined by comparison with digital subtraction angiography (DSA). Methods: Over a period of 18 months a total of 106 patients in whom a subarachnoidal hemorrhage had been detected on native CT were examined in parallel by spiral CT and DSA. CT-angiography was performed under standardized parameters and included processing with 3D surface reconstructions. Results: In 64 patients (60.4%) at total of 72 aneurysms were detected. In four cases (6.2%) there were two and in two cases (3.1%) even three aneurysms. The findings of DSA and CTA agreed in 98 cases (92.5%). In four patients (3.8%) a false negative results was obtained in CTA and the initial DSA. Conclusions: Digital subtraction angiography must still be considered as the gold standard in the diagnosis of cerebral aneurysms. On account of its excellent spatial delineation of aneurysms and possibilities for exact measurements, CT-angiography represents a valuable, supplementary method - in some cases also an alternative method - to digital subtraction angiography. (orig.) [de

  16. Angiography and interventional radiology of the kidneys

    International Nuclear Information System (INIS)

    Hansmann, J.; Richter, G.M.; Hallscheidt, P.; Duex, M.; Noeldge, G.; Kaufmann, G.W.

    1999-01-01

    For imaging of renal pathology a broad spectrum of radiologic diagnostic procedures are available which are, sometimes and particularly more recently, competing among each other in their diagnostic yield and relevance. For tumorous lesions ultrasound, computed tomography and magnetic resonance imaging are performed predominantly. Angiography is no longer required with the exception of highly selected cases and in some specific preoperative workup requirements. Until recently, catheter based digital subtraction angiography has been considered as gold standard. However, non-invasive techniques such as CT-angiography and MR-angiography are evolving parallel to their quantum leap of resolutions and readiness to use. Nevertheless, well accepted criteria for quality assessement of these new modalities are still lacking. More comparison studies are urgently warranted. Despite the availability of ultrashort pulse sequences applying the T1 relaxation reduction effect of gadolinium enhanced MR techniques overestimation of renal artery stenosis still poses a substantial problem. Renal intervention implies a variety of procedures such as plain angioplasty, stent placement, embolization of traumatic and both benign and malignant tumors. These methods have emerged over the last two decades from a more experimental nature to a fully accepted treatment option. When renal artery angioplasty is embedded in an aggressive approach including stenting as an adjunct for more complex cases, renal ostial lesions and a well organized follow-up regimen its therapeutic potential for treatment of renal insufficiency, malignant hypertension, for organ preservation bears a very high potential. Provided adequate periinterventional drug regimen restenosis rates may be as low as 10%. In highly selected cases capillary embolization might be used as an alternative to nephrectomy with a similar clinical outcome. Particularly the development of superselective small caliber embolization catheters

  17. Ferumoxytol as an off-label contrast agent in body 3T MR angiography: a pilot study in children

    Energy Technology Data Exchange (ETDEWEB)

    Ruangwattanapaisarn, Nichanan [Mahidol University, Department of Diagnostic and Therapeutic Radiology, Ramathibodi Hospital, Bangkok (Thailand); Stanford University, Department of Radiology, Stanford, CA (United States); Hsiao, Albert; Vasanawala, Shreyas S. [Stanford University, Department of Radiology, Stanford, CA (United States)

    2015-06-15

    Ferumoxytol is an ultrasmall superparamagnetic iron oxide (USPIO) nanoparticle agent used to treat iron deficiency anemia in adults with chronic kidney disease. We aim to determine the feasibility of using ferumoxytol for clinical pediatric cardiac and vascular imaging. We retrospectively identified 23 consecutive children who underwent MRI with ferumoxytol (11 males; mean age: 7.4 years, range: 3 days-18 years), yielding 12 abdominal MR angiography and 15 cardiac MRI studies. Medical records were reviewed for the clinical indication, ferumoxytol dose, injection rate, sedation and any complication. A two-reader consensus scored the images on a five-point scale for overall image quality and delineation of various anatomical structures. Signal-to-background ratios for abdominal aorta and inferior vena cava for abdominal cases and blood pool-myocardium contrast ratios for cardiac cases were calculated. The confidence intervals for obtaining a score of three or above for each image parameter were calculated by using adjusted Wald method. For abdominal MR angiography, average scores for overall image quality, as well as delineation of the hepatic artery, superior mesenteric artery, renal artery and veins were 4.5, 4.3, 4.3, 3.7 and 4.7, respectively. For cardiac exams, the average scores for overall image quality, systemic arteries, pulmonary arteries, pulmonary veins, valves and ventricles were 4.4, 4.6, 4.1, 4.8, 4.1 and 4.7, respectively. For all parameters, the lower bound for the proportion of cases to have a score of 3 or above was 65%. Signal-to-background ratios for aorta and abdominal veins averaged 86 +/- 74 and 86 +/- 77 for full-dose images, and 23 and 18 for half-dose images, respectively. Mean blood pool to myocardium contrast ratio was 3:3. Ferumoxytol can provide excellent image quality for pediatric body MR angiography/MR venography at a dose of 1.5 or 3 mg Fe/kg. Further investigation should be directed toward understanding the lowest dose that can be

  18. Coronary angiography using synchrotron radiation

    International Nuclear Information System (INIS)

    Akatsuka, Takao; Hiranaka, Yukio; Takeda, Tohru; Hyodo, Kazuyuki.

    1990-01-01

    Invasive coronary angiography is the imaging technique of choice for diagnosis of ischemic heart disease. Recently, the application of synchrotron radiation in coronary angiography has been investigated in the world, with the aim of developing the noninvasive technique for visualizing the heart. In this article, backgrounds and present situation of coronary angiography using synchrotron radiation are reviewed. Firstly, visual imaging techniques of the cardiovascular system are discussed in terms of angiography and digital subtraction angiography (DSA). Conventional temporal, energy, and hybrid subtraction modes used in DSA are referred to. Secondly, the application of synchrotron radiation is presented, focusing on the property of synchrotron radiation and K-edge subtraction angiography. Two kinds of synchrotron radiation beam methods are outlined. Interpretation of image data and various subtraction procedures remain unestablished. There is much to be done before coronary angiography using synchrotron radiation comes into a clinical practice. (N.K.)

  19. High-resolution ex vivo magnetic resonance angiography: a feasibility study on biological and medical tissues

    Directory of Open Access Journals (Sweden)

    Boel Lene WT

    2010-03-01

    Full Text Available Abstract Background In biomedical sciences, ex vivo angiography is a practical mean to elucidate vascular structures three-dimensionally with simultaneous estimation of intravascular volume. The objectives of this study were to develop a magnetic resonance (MR method for ex vivo angiography and to compare the findings with computed tomography (CT. To demonstrate the usefulness of this method, examples are provided from four different tissues and species: the human placenta, a rice field eel, a porcine heart and a turtle. Results The optimal solution for ex vivo MR angiography (MRA was a compound containing gelatine (0.05 g/mL, the CT contrast agent barium sulphate (0.43 mol/L and the MR contrast agent gadoteric acid (2.5 mmol/L. It was possible to perform angiography on all specimens. We found that ex vivo MRA could only be performed on fresh tissue because formalin fixation makes the blood vessels permeable to the MR contrast agent. Conclusions Ex vivo MRA provides high-resolution images of fresh tissue and delineates fine structures that we were unable to visualise by CT. We found that MRA provided detailed information similar to or better than conventional CTA in its ability to visualize vessel configuration while avoiding interfering signals from adjacent bones. Interestingly, we found that vascular tissue becomes leaky when formalin-fixed, leading to increased permeability and extravascular leakage of MR contrast agent.

  20. Coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2009-07-01

    Coronary CT angiography has attained increasing scientific attention at academic institutions and has become a highly accurate diagnostic modality. Extending this knowledge into a practice setting is the purpose of 'Coronary CT Angiography'. This book will assist you in integrating cardiac CT into your daily practice, while also giving an overview of the current technical status and applications. The specific features of scanners from all four main vendors are also presented providing an objective overview of noninvasive coronary angiography using CT. (orig.)

  1. Angiography in angiology

    International Nuclear Information System (INIS)

    Zeitler, E.; Grosse-Vorholt, R.

    1980-01-01

    A review is given of recent developments in angiography including advances in the equipment, in the technique and in image processing. Indications for and interpretation of angiography are discussed and angiographic-therapeutic procedures are considered. (C.F.)

  2. Coronary MR angiography: current status

    International Nuclear Information System (INIS)

    Danias, P.G.; Manning, W.J.

    2000-01-01

    Since first described in the early 1990s, coronary magnetic resonance angiography (MRA) has evolved as a promising noninvasive modality for imaging of the coronary arteries and evaluation of coronary artery disease. Despite technical limitations, coronary MRA has established value for imaging of anomalous coronary arteries and assessment of bypass graft patency. Current research focuses on the development of optimal respiratory compensation strategies, improved spatial and temporal resolution and faster acquisition of image data. The accurate detection of stenoses and assessment of the severity of coronary atherosclerosis is presently being evaluated with large multi-center studies. With further technique enhancements and more clinical experience, coronary MRA is likely to become the dominant noninvasive modality in clinical cardiology. (orig.) [de

  3. Carotid stenosis: a comparison between MR and spiral CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Magarelli, N.; Carriero, A.; Bonomo, L. [Institute of Radiology, University ``G. D`Annunzio``, Chieti (Italy); Scarabino, T.; Simeone, A.L.; Florio, F. [IRCCS, Foggia (Italy); Salvolini, U. [Department of Neuroradiology, University of Ancona (Italy)

    1998-06-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.) With 6 figs., 4 tabs., 17 refs.

  4. Carotid stenosis: a comparison between MR and spiral CT angiography

    International Nuclear Information System (INIS)

    Magarelli, N.; Carriero, A.; Bonomo, L.; Scarabino, T.; Simeone, A.L.; Florio, F.; Salvolini, U.

    1998-01-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.)

  5. Improvement of chemical shift selective saturation (CHESS) pulse for MR angiography

    International Nuclear Information System (INIS)

    Ishimori, Yoshiyuki; Sashie, Hiroyuki; Hiraga, Akira; Matsuda, Tsuyoshi

    2000-01-01

    We improved the fat suppression technique based on chemical shift selective saturation (CHESS). To do this, we shortened the duration of the CHESS pulse to achieve a short repetition time (TR) for MR angiography (MRA). A short-duration CHESS pulse causes broad frequency band saturation, creating extensive offset from the resonance frequency of water. In our phantom experiment, the best parameters of the short-duration CHESS pulse were 3.84 ms in duration, -650 Hz in offset frequency from water resonance, and had a 130-degree flip angle. With this technique, MRA will be able to be carried out without a significant increase in TR. Thus, better vessel contrast will be maintained in time-of-flight (TOF) MRA or contrast-enhanced MRA when using the maximum intensity projection (MIP) method. (author)

  6. Equilibrium-phase MR angiography: Comparison of unspecific extracellular and protein-binding gadolinium-based contrast media with respect to image quality.

    Science.gov (United States)

    Erb-Eigner, Katharina; Taupitz, Matthias; Asbach, Patrick

    2016-01-01

    The purpose of this study was to compare contrast and image quality of whole-body equilibrium-phase high-spatial-resolution MR angiography using a non-protein-binding unspecific extracellular gadolinium-based contrast medium with that of two contrast media with different protein-binding properties. 45 patients were examined using either 15 mL of gadobutrol (non-protein-binding, n = 15), 32 mL of gadobenate dimeglumine (weakly protein binding, n = 15) or 11 mL gadofosveset trisodium (protein binding, n = 15) followed by equilibrium-phase high-spatial-resolution MR-angiography of four consecutive anatomic regions. The time elapsed between the contrast injection and the beginning of the equilibrium-phase image acquisition in the respective region was measured and was up to 21 min. Signal intensity was measured in two vessels per region and in muscle tissue. Relative contrast (RC) values were calculated. Vessel contrast, artifacts and image quality were rated by two radiologists in consensus on a five-point scale. Compared with gadobutrol, gadofosveset trisodium revealed significantly higher RC values only when acquired later than 15 min after bolus injection. Otherwise, no significant differences between the three contrast media were found regarding vascular contrast and image quality. Equilibrium-phase high-spatial-resolution MR-angiography using a weakly protein-binding or even non-protein-binding contrast medium is equivalent to using a stronger protein-binding contrast medium when image acquisition is within the first 15 min after contrast injection, and allows depiction of the vasculature with high contrast and image quality. The protein-binding contrast medium was superior for imaging only later than 15 min after contrast medium injection. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Magnetic resonance angiography

    International Nuclear Information System (INIS)

    Kauczor, H.U.; Gamroth, A.H.; Schad, L.R.; Semmler, W.; Kaick, G. van; Tuengerthal, S.J.; Hausmann, R.

    1992-01-01

    MR angiography (MRA) proved to be promising combined to MR-Imaging (MRI) in the assessment of intrathoracic masses. Sequential FLASH 2D-angiograms were acquired in breathhold technique using the following parameters: TR=30 ms, TE=10 ms, FA=30deg. Section thickness was 5 mm with 1 mm overlap between sequential sections. Individual conditions of the examination were achieved by an automatised control procedure. Targeted MIP-postprocessing resulted in 3D-reconstructions illustrating vascular anatomy and avoiding superimposition. Presentation should be done by cine-mode for better spatial impression. This method was evaluated in a prospective study of 21 patients with malignant pulmonary and mediastinal masses in addition to spin-echo imaging. The diagnostic contribution concerning the relationship between the mass and the vasculature like displacement, stenosis, and poststenotic perfusion defect were assessed. (orig.) [de

  8. MR angiography, MR imaging and proton MR spectroscopy in-vivo assessment of skeletal muscle ischemia in diabetic rats.

    Directory of Open Access Journals (Sweden)

    Stefano Delli Pizzi

    Full Text Available To prospectively evaluate the feasibility of using magnetic resonance (MR techniques for in-vivo assessing a rat diabetic model of limb ischemia. Unilateral hind limb ischemia was induced by ligation of the iliac-femoral artery in male streptozotocin-treated and non-diabetic control rats. Four weeks after ligation, rats underwent MR Angiography (MRA, T(1-weighted and Short Time Inversion Recovery (STIR sequences and muscle Proton MR Spectroscopy ((1H-MRS on both hind limbs. After MR examinations, immunoblotting and immunofluorescence analysis were performed. MRA showed a signal void due to flow discontinuation distal to the artery ligation. T(1-weighted and STIR images showed, respectively, the presence of tissue swelling (p = 0.018 for non-diabetic; p = 0.027 for diabetic rats and signal hyperintensity in tissue affected by occlusion. Mean total creatine/water for the occluded limb was significantly lower than for the non-occluded limbs in both non-diabetic (5.46×10(-4 vs 1.14×10(-3, p = 0.028 and diabetic rats (1.37×10(-4 vs 1.10×10(-3; p = 0.018. MR Imaging and (1H-MRS changes were more pronounced in diabetic than in non-diabetic occluded limbs (p = 0.032. MR findings were confirmed by using histological findings. Combined MR techniques can be used to demonstrate the presence of structural and metabolic changes produced by iliac-femoral artery occlusion in rat diabetic model of limb ischemia.

  9. Evaluation of the patency of an extracranial-intracranial bypass using magnetic resonance angiography with selective presaturation of bypass vessels

    Energy Technology Data Exchange (ETDEWEB)

    Mabuchi, Shoji; Nakayama, Naoki; Isu, Toyohiko; Harata, Tatsuo; Nanbu, Toshikazu [Kushiro Rousai Hospital, Hokkaido (Japan)

    1994-06-01

    Three-dimensional time-of-flight magnetic resonance (MR) angiography using radiofrequency presaturation pulses was used to evaluate the patency of extracranial-intracranial (EC/IC) bypass in 11 patients. Presaturation causes signal loss in the vascular territory supplied by the presaturated EC/IC bypass graft. In all patients with a patent EC/IC bypass graft confirmed on conventional angiography, disappearance of the signal of the middle cerebral artery receiving blood flow from the bypass graft was clearly observed on MR angiograms with presaturation, indicating patency of the EC/IC bypass graft. MR angiography with presaturation pulses is a noninvasive and repeatable method for evaluation of the function of an EC/IC bypass graft. (author).

  10. Phase-contrast MR angiography of intracranial dural arteriovenous fistulae

    International Nuclear Information System (INIS)

    Cellerini, M.; Mascalchi, M.; Mangiafico, S.; Ferrito, G.P.; Scardigli, V.; Pellicano, G.; Quilici, N.

    1999-01-01

    MRI and phase-contrast MR angiography (PC MRA) were obtained in 13 patients with angiographically confirmed intracranial dural arteriovenous fistulae (DAVF). Three- and two-dimensional PC MRA was obtained with low (6-20 cm/s) and high (>40 cm/s) velocity encoding along the three main body axes. MRI showed focal or diffuse signal abnormalities in the brain parenchyma in six patients, dilated cortical veins in seven, venous pouches in four with type IV DAVF and enlargement of the superior ophthalmic vein in three patients with DAVF of the cavernous sinus. However, it showed none of the fistula sites and did not allow reliable identification of feeding arteries. 3D PC MRA enabled identification of the fistula and enlarged feeding arteries in six cases each. Stenosis or occlusion of the dural sinuses was detected in six of eight cases on 3D PC MRA with low velocity encoding. In six patients with type II DAVF phase reconstruction of 2D PC MRA demonstrated flow reversal in the dural sinuses or superior ophthalmic vein. (orig.)

  11. Usefulness of MR angiography with fat- and water-suppression technique

    International Nuclear Information System (INIS)

    Ohta, Fumihito; Kagawa, Takato; Kawamitsu, Hideaki; Fukuma, Atsushi; Nagao, Seiichi; Takaya, Mikio; Kimura, Reishin; Yamasaki, Toshiki; Moritake, Kouzo

    1994-01-01

    The purpose of this study was to improve visualization of intracranial vessels by the use of time-of-flight MR angiography with the fat- and water-suppression technique (TOF-MRA-presat). Two groups of individuals were studied. They were 35 patients with ischemic cerebrovascular disorders (lacunar group) and 22 volunteers (control group). TOF-MRA-presat suppressed the signal of the background tissue, including fat and brain parenchyma. The contrast between background tissue and blood vessels was thus improved. The visibility of the ophthalmic artery, the posterior communicating artery, and the superior cerebellar artery in the control group increased noticeably in the TOF-MRA-presat images as compared with the TOF-MRA images. Similarly, the visibility of the insular segment of the middle cerebral artery, the posterior temporal artery, and the calcarine artery in the lacunar group was also better in TOF-MRA-presat images than in TOF-MRA-images. These results indicate that TOF-MRA-presat dose improve the visualization of intracranial vessels. (author)

  12. Angiography - interventional diagnostic applications

    International Nuclear Information System (INIS)

    Schild, H.

    1994-01-01

    The angiography system is very different from the other systems used in diagnostic radiology. The invasivity of angiography requires special, high standards in theoretical and practical training and experience both of beginners and experienced personnel. This textbook fully meets the demand for in-depth and exhaustive information, as it presents: - The fundamentals and techniques of angiography, the vascular anatomy, and many hints and tips of great help in practice. - A comprehensive survey of diagnostic problems and examination approaches, including neuro-angiography, with 221 reproductions of original angiographs, and additional schematic representations. - A special chapter devoted to indication and relevant techniques for the major vascular interventional examinations. - A great number of tables explain at a glance standard examination techniques, indications and diagnostic criteria. (orig./CB) [de

  13. Peripheral MR Angiography of Klippel-Trenaunay Syndrome

    International Nuclear Information System (INIS)

    Fontana, Alessandro; Olivetti, Lucio

    2004-01-01

    Klippel-Trenaunay syndrome (KTS) is a rare congenital vascular disease of unknown etiology that affects one or more limbs. It is characterized clinically by three physical findings (the so-called triad): port-wine stain hemangioma, hypertrophy of the bony and/or soft tissue, and varicose veins. A review of the medical literature in 1999 revealed about 1,000 case studies. We present here the case of a patient with clinical diagnosis of KTS studied using peripheral magnetic resonance angiography

  14. Artifacts in MR angiography of the intracranial vessels using the 3D TOF and 3D PC techniques

    International Nuclear Information System (INIS)

    Park, Dong Woo; Lee, Seung Ro; Hahm, Chang Kok; Kim, Yong Soo; Park, Choong Ki

    1997-01-01

    To classify artifacts and to assess their frequency in magnetic resonance angiography of intracranial vessels using three- dimensional time-of-flight and phase-contrast techniques. One hundred and eleven patients with suspected cerebrovascular disease were imaged on a 1.5T superconducting magnetic resonance machine employing three- dimensional time-of-flight and phase-contrast magnetic resonance angiographic techniques. We retrospectively reviewed the artifacts in three- dimensional time-of-flight and phase-contrast magnetic resonance angiography of the intracranial circulatory system, comparing them with routine spin-echo magnetic resonance images and magnetic resonance angiography source images, and partially with conventional angiography. Artifacts in magnetic resonance angiography were classified as flow-related, and flow-unrealted, by patient, hardware, magnetic resonance angiography acquisition and postprocessing techniques. Type and frequency of flow-related artifacts included saturation artifact (100%), dephasing artifact (100%), phase-encoding ghost artifact (97%), turbulence artifact (14%) and flow displacement artifact (5%) on three- dimensional time-of-flight and phase-contrast magnetic resonance angiography, and phase aliasing artifact (2%) on three-dimensional phase-contrast magnetic resonance angiography. Type and frequency of flow-unrelated artifacts included stair-step artifact (100%) by three- dimensional reconstruction process, magnetic susceptibility artifact by carotid canal (69%) and metal (4%), maximum intensity projection artifact (30%) by maximum intensity projection algorithm, and motion artifact by respiration (20%) and voluntary movement (8%); these were seen on both time-of-flight and phase-contrast magnetic resonance angiography. Paramagnetic substance artifact by fat and paranasal sinus mucosa (100%), hematoma (14%) and gadolinium (5%) were seen on time-of-flight magnetic resonance angiography. In three- dimensional time-of-flight and

  15. Analysis of flow dynamics of main pulmonary artery by cine phase contrast MR angiography

    International Nuclear Information System (INIS)

    Honda, Norinari; Machida, Kikuo; Mamiya, Toshio

    1996-01-01

    Nineteen studies of cine phase contrast MR angiography (PCMRA) of main pulmonary artery (MPA) entered the study. Cine PCMRA was obtained by a 1.5T MR imager with a gradient echo sequence coupled with velocity encoding bipolar pulses. Retrospective EKG gating was used. Mean velocity, maximum velocity, and maximum flow rate of MPA were 6.2 to 28 cm/s (mean/SD 13/5.1, n=18), 61 to 148 cm/s (mean/SD 102/30, n=13), and 12,561 to 30,113 ml/min (mean/SD 18,730/5,464, n=18), respectively. Retrograde flow in the MPA was noted to begin at late-to mid-systole. Retrograde flow occurred first in the posterior part (15/19) or occurred from periphery (4/19). Thus hemodynamic parameters and velocity maps of MPA can be obtained by cine PCMRA. (author)

  16. Optimized respiratory-resolved motion-compensated 3D Cartesian coronary MR angiography.

    Science.gov (United States)

    Correia, Teresa; Ginami, Giulia; Cruz, Gastão; Neji, Radhouene; Rashid, Imran; Botnar, René M; Prieto, Claudia

    2018-04-22

    To develop a robust and efficient reconstruction framework that provides high-quality motion-compensated respiratory-resolved images from free-breathing 3D whole-heart Cartesian coronary magnetic resonance angiography (CMRA) acquisitions. Recently, XD-GRASP (eXtra-Dimensional Golden-angle RAdial Sparse Parallel MRI) was proposed to achieve 100% scan efficiency and provide respiratory-resolved 3D radial CMRA images by exploiting sparsity in the respiratory dimension. Here, a reconstruction framework for Cartesian CMRA imaging is proposed, which provides respiratory-resolved motion-compensated images by incorporating 2D beat-to-beat translational motion information to increase sparsity in the respiratory dimension. The motion information is extracted from interleaved image navigators and is also used to compensate for 2D translational motion within each respiratory phase. The proposed Optimized Respiratory-resolved Cartesian Coronary MR Angiography (XD-ORCCA) method was tested on 10 healthy subjects and 2 patients with cardiovascular disease, and compared against XD-GRASP. The proposed XD-ORCCA provides high-quality respiratory-resolved images, allowing clear visualization of the right and left coronary arteries, even for irregular breathing patterns. Compared with XD-GRASP, the proposed method improves the visibility and sharpness of both coronaries. Significant differences (p respiratory phases with larger motion amplitudes and subjects with irregular breathing patterns. A robust respiratory-resolved motion-compensated framework for Cartesian CMRA has been proposed and tested in healthy subjects and patients. The proposed XD-ORCCA provides high-quality images for all respiratory phases, independently of the regularity of the breathing pattern. © 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  17. Comparison of MR angiography with conventional angiography in cervical and intracranial vascular disease

    International Nuclear Information System (INIS)

    Choi, D. S.; Chang, K. H.; Jung, H. W.; Han, M. H.

    1995-01-01

    To assess the usefulness of magnetic resonance angiography (MRA) in evaluation of stenosis of carotid and large cerebral vessels and cerebral aneurysm. Twenty-seven patients with either arterial stenosis in cervical or intracranial major vessels (n = 18) or cerebral aneurysm (n = 8) or both (n 1) were examined with both MRA and conventional angiography (CA). MRA was performed with 3D TOF technique with magnetization transfer suppression at 1.5T system (Magnetom, Siemens, Germany); both intracranial MRA and cervical MRA in 16 patients, intracranial MRA only in the remaining patients. For evaluation of arterial stenosis, 32 carotid bifurcations and 383 segments of intracranial major vessels were assessed in blind fashion, and were compared with those of CA. Each arterial segment was arbitrarily classified into one of five grades (< 10, 10-49, 50-74, 75-99, 100%) for carotid bifurcation and one of four (< 10, 10-49, 50-99, 100%) for intracranial vessels. For aneurysm, its location, size shape and direction were compared. For arterial stenosis, concordance rate between MRA and CA was 88% (28/32) in carotid bifurcation and 89% (340/383) in intracranial vessels. All discordant cases were overgraded on MRA. For aneurysm, 7 of 9 were demonstrated on both MRA and CA, one of which was partially demonstrated on MRA. One of the other two patients showed aneurysm only on MRA, whereas the remaining one revealed aneurysm only on CA. MRA may be performed as a screening test for occlusive disease of cervical and major intracranial vessels and cerebral aneurysm

  18. MR angiography of the carotid arteries and intracranial circulation: advantage of a high relaxivity contrast agent

    International Nuclear Information System (INIS)

    Anzalone, N.; Scotti, R.; Iadanza, A.

    2006-01-01

    Several studies have shown the usefulness of contrast-enhanced MR angiography (CE-MRA) for imaging the supraortic vessels, and, as a consequence, it has rapidly become a routine imaging modality. The main advantage over unenhanced techniques is the possibility to acquire larger volumes, allowing demonstration of the carotid artery from its origin to the intracranial portion. Most published studies on CE-MRA of the carotid arteries have been performed with standard Gd-based chelates whose T1 relaxivity values are similar. Recently new gadolinium chelates such as gadobenate dimeglumine (Gd-BOP-TA, MultiHance; Bracco Imaging, Milan, Italy) have been developed which have markedly higher intravascular T1 relaxivity values. When administered at an equivalent dose to that of a standard agent, these newer contrast agents produce significantly greater intravascular signal enhancement. The availability of an appropriate high-relaxivity contrast agent might also help to overcome some of the intrinsic technical problems (e. g. those related to flow) that affect time-of-flight (TOF) and phase contrast (PC) MR angiography of the intracranial vasculature. To avoid the problem of superimposition of veins, ultrafast gradient echo MRA techniques with very short TR and TE have been developed. Although the precise sequence parameters vary between manufacturers, they are basically similar. The choice between performing a time-resolved or high spatial resolution CE-MRA examination depends upon the precise clinical application. The most common applications include the study of cerebral aneurysms, arteriovenous malformations, dural arteriovenous fistulas and dural venous diseases

  19. Dynamic coronary MR angiography in a pig model with hyperpolarized water

    DEFF Research Database (Denmark)

    Lipsø, Hans Kasper Wigh; Hansen, Esben Søvsø Szocska; Tougaard, Rasmus Stilling

    2018-01-01

    To investigate dynamic coronary MR angiography using hyperpolarized water as a positive contrast agent. Hyperpolarization can increase the signal by several orders of magnitude, and has recently been translated to human cardiac application. The aim was to achieve large 1 H signal enhancement...... to allow high-resolution imaging of the coronary arteries. Protons in D2 O were hyperpolarized by dissolution dynamic nuclear polarization. A total of 18 mL of hyperpolarized water was injected into the coronary arteries of healthy pigs (N = 9; 3 injections in 3 animals). The MRI images were acquired...... with a gradient-echo sequence in an oblique slab covering the main left coronary arteries with 0.55 mm in-plane resolution. The acquisition time was 870 ms per frame. A more than 200-fold signal enhancement compared with thermally polarized water at 3 T was obtained. Coronary angiographic images with a signal...

  20. Risk of renal allograft rejection following angiography

    International Nuclear Information System (INIS)

    Heideman, M.; Claes, G.; Nilson, A.E.

    1976-01-01

    In a retrospective study of 173 immediately functioning primary kidney transplants, correlation between angiography and renal allograft rejection was studied during the first 14 days. It was found that rejection was more frequent in kidneys undergoing angiography than in those not undergoing angiography. It was also found that in kidneys undergoing angiography an overwhelming number of the rejections started the day after angiography. These differences in rejection frequency could not be explained by differences in HLA matching or the origin of the kidneys. These findings suggest a possible connection indicating that the angiography might elicit an acute rejection episode. A possible mechanism for starting this reaction might be activation of the complement system which was found in 50 percent of the patients undergoing angiography in peripheral blood and in 100 percent when studied in vitro

  1. Digital subtraction angiography in ischemic cerebrovascular accidents

    Energy Technology Data Exchange (ETDEWEB)

    Manelfe, C.; Bonafe, A.; Ducos de Lahitte, M.; Rascol, A.; Prere, J.; Guiraud, B.; Marc-Vergnes, J.P. (Hopital Purpan, 31 - Toulouse (France))

    1983-12-29

    Recent advances in computer and radiological technology have permitted reassessment of intravenous angiography in the evaluation of cerebrovascular disorders. Although digital subtraction angiography is a relatively new technique, it has rapidly gained a widespread acceptance. It has extended the use of angiography to outpatients and to people in whom conventional angiography is contraindicated. This reliable, safe, and relatively noninvasive technique offers the user two benefits: real-time subtraction and enhanced image quality. The system allows angiographic evaluation of the extracranial and intracranial vessels by means of intravenous injection of contrast material. Extracranial studies clearly demonstrate stenoses and occlusions of the major cervicocephalic arteries. Intracranial studies usually detect major cerebrovascular occlusions and provide insight into the collateral flow patterns. Intravenous digital subtraction angiography permits accurate assessment of cervicocephalic vessels after surgical repair. Although intravenous digital subtraction angiography obviates the need for conventional angiography in many cases, movements from the patients, or superimposition of vascular structures can substantially degrade the quality of the images. Digital subtraction angiography with intra-arterial injection of contrast medium will be contemplated in patients with poor intravenous digital subtraction angiography studies prior to surgery.

  2. Digital subtraction angiography in ischemic cerebrovascular accidents

    International Nuclear Information System (INIS)

    Manelfe, C.; Bonafe, A.; Ducos de Lahitte, M.; Rascol, A.; Prere, J.; Guiraud, B.; Marc-Vergnes, J.P.

    1983-01-01

    Recent advances in computer and radiological technology have permitted reassessment of intravenous angiography in the evaluation of cerebrovascular disorders. Although digital subtraction angiography is a relatively new technique, it has rapidly gained a widespread acceptance. It has extended the use of angiography to outpatients and to people in whom conventional angiography is contraindicated. This reliable, safe, and relatively noninvasive technique offers the user two benefits: real-time subtraction and enhanced image quality. The system allows angiographic evaluation of the extracranial and intracranial vessels by means of intravenous injection of contrast material. Extracranial studies clearly demonstrate stenoses and occlusions of the major cervicocephalic arteries. Intracranial studies usually detect major cerebrovascular occlusions and provide insight into the collateral flow patterns. Intravenous digital subtraction angiography permits accurate assessment of cervicocephalic vessels after surgical repair. Although intravenous digital subtraction angiography obviates the need for conventional angiography in many cases, movements from the patients, or superimposition of vascular structures can substantially degrade the quality of the images. Digital subtraction angiography with intra-arterial injection of contrast medium will be contemplated in patients with poor intravenous digital subtraction angiography studies prior to surgery [fr

  3. MR respiratory navigator echo gated coronary angiography at 3 T

    International Nuclear Information System (INIS)

    Chang Shixin; Wang Yibin; Zong Genlin; Hao Nanxin; Du Yushan

    2007-01-01

    Objective: To investigate the techniques and influence factors for the respiratory navigator echo triggered whole-heart coronary MR angiography (WH-CMRA) and evaluate its application in visualizing coronary arteries and the image quality. Methods: Ninety two volunteers were acquired with WH-CMRA at 3 T MR scanner using respiratory navigator-echo gated TFE sequence. Imaging quality was visually graded as 0-IV grade according to the visual inspection, average length, diameter and sharpness of coronary arteries. The correlation between the imaging quality and respiratory pattern, heart rate and navigator efficiency was analyzed. Results: The imaging quality in 92 cases was that 28 were graded as IV, 53 were graded as III, 9 were graded as II and 2 were graded as I. The successful rate of scan was 88% (81/92). The imaging quality is mainly graded as IV when the heart rate was less than 75 beats per minute (bpm) and the sharpness of vessel was (48±11)%. When heart rate was more than 75 bpm, the image quality was mostly graded as 111 and the sharpness was (33±15)%. The correlation between heart rate and imaging quality score was negative (r= -0.726, P O.05). Conclusion: 3 T WH-CMRA technique could facilitated the visualization of whole coronary arteries at free breathing but having indications on heart rate. (authors)

  4. Is fasting necessary for elective cerebral angiography?

    Science.gov (United States)

    Kwon, O-K; Oh, C W; Park, H; Bang, J S; Bae, H-J; Han, M K; Park, S-H; Han, M H; Kang, H-S; Park, S-K; Whang, G; Kim, B-C; Jin, S-C

    2011-05-01

    In order to prevent unexpected events such as aspiration pneumonia, cerebral angiography has been performed under fasting in most cases. We investigated prospectively the necessity of fasting before elective cerebral angiography. The study is an open-labeled clinical trial without random allocation. In total, 2554 patients who underwent elective cerebral angiography were evaluated on development of nausea, vomiting, and pulmonary aspiration during and after angiography. Potential risks and benefits associated with fasting were provided in written documents and through personal counseling to patients before the procedure. The patients chose their fasting or nonfasting option. No restriction in diet was given after angiography. The patients were observed for 24 hours. Nausea and vomiting during and within 1 hour after angiography was considered as a positive event associated with cerebral angiography. The overall incidence of nausea and vomiting during and within 1 hour after angiography was 1.05% (27/2554 patients). There was no patient with pulmonary aspiration. No statistical difference in nausea and vomiting development between the fasting and the diet groups was found. The incidence of nausea and vomiting associated with cerebral angiography is low and not affected by diet or fasting. Pulmonary aspiration had no difference between the diet and the fasting group. Our study suggests that fasting may not be necessary for patients who undergo elective cerebral angiography.

  5. Indications for coronary angiography

    International Nuclear Information System (INIS)

    Kaltenbach, M.; Vallbracht, C.

    1985-01-01

    Today selective coronary angiography, introduced by Sones in 1957, is used as clinical routine for diagnosing morphological changes in the coronary arteries. Hitherto, more recent techniques such as digital subtraction angiography cannot provide comparable information. Strict criteria for its indication depending on possible therapeutic consequences, have to be applied, although the risk is low with a letality of 0.01 to 0.05 percent. Radionuclear investigations can be used as additional tool in selected cases. The careful indication for coronary angiography usually implies the possible need for coronary bypass graft surgery of balloon angioplasty. (orig./MG) [de

  6. Multi-section CT angiography compared with digital subtraction angiography in diagnosing major arterial hemorrhage in inflammatory pancreatic disease

    International Nuclear Information System (INIS)

    Hyare, Harpreet; Desigan, Sharmini; Nicholl, Helen; Guiney, Michael J.; Brookes, Jocelyn A.; Lees, William R.

    2006-01-01

    Purpose: Major arterial hemorrhage is an uncommon but serious complication of pancreatitis with high morbidity and mortality. Digital subtraction angiography (DSA) has long been the gold standard for the detection of a visceral artery pseudoaneurysm or for the site of active bleeding in patients with pancreatitis. Multi-section CT angiography is a minimally invasive technique which can provide high-resolution and high-contrast images of the arterial lumen and wall, with a much lower risk of complication and morbidity compared to DSA. The aim of this study was to determine the accuracy of multi-section CT angiography for the diagnosis of arterial complications of inflammatory pancreatitic disease. Materials and methods: A retrospective analysis of all patients undergoing visceral angiography for major bleeding as a complication of pancreatitis between 1998 and 2004 was performed. Twenty-nine studies in 25 patients (20 males, 5 females) with a mean age of 50.9 years (range 11-67 years) were identified where multi-section CT angiography was performed in the 24 h preceding the digital subtraction angiogram. Results: Digital subtraction angiography detected a pseudoaneurysm or contrast extravasation in 19 studies and no bleeding was demonstrated in 9 studies. CT angiography correctly identified the site and type of bleeding in 18 of the 19 positive studies. CT angiography detected extravasation of contrast in one study that was not demonstrated on digital subtraction angiography. The sensitivity and specificity for multi-section CT angiography for the detection of major arterial bleeding on a background of pancreatitis were 0.947 and 0.900, respectively. Conclusion: Multi-section CT angiography is a sensitive and accurate technique for the detection of major arterial hemorrhage in inflammatory pancreatic disease and should be considered as the first investigation in the management of these patients

  7. The value of MR angiography in the diagnosis of deep vein thrombosis of the lower limbs: comparative study with DSA

    International Nuclear Information System (INIS)

    Feng Min; Wang Shuzhi; Gu Jianping; Sun Jun; Mao Cunnan; Lu Lingquan; Yin Xindao

    2007-01-01

    Objective: To assess the clinical values of MR angiography (MRA) in the detection of deep vein thrombosis of the lower limbs. Methods: Two-dimensional time of flight (2D TOF) MRA was performed in thirty patients who were suspected of having deep vein thrombosis in the lower limbs. The findings of MRA were compared to that of digital subtraction angiography (DSA). Results: twenty-five cases showed deep vein thrombosis in the lower limbs, the MRA findings included venous filling defect (14 cases), occlusions and interruptions of veins (8 cases), venous recanalizations (3 cases), collateral veins (25 cases). Taking the results of DSA as a golden standard, MRA detected all of the affected cases with only one case as the false positive. Conclusion: 2D TOF MRA is a method of choice in the diagnosis of deep vein thrombosis of the lower limbs. (authors)

  8. 3D-CT angiography. Intracranial arterial lesions

    Energy Technology Data Exchange (ETDEWEB)

    Asato, Mikio; Tong, X.Q.; Tamura, Shozo [Miyazaki Medical Coll., Kiyotake (Japan)] [and others

    1997-06-01

    Since its introduction, three dimensional CT angiography (3D-CTA) on spiral (helical) CT has played an important role in clinical imaging. Initially it was reported to be useful in depicting aortic abnormalities, afterwards the merit in detecting intracranial aneurysm by 3D-CTA was also described. We have investigated the usefullness of 3D-CTA in detecting patients of intracranial aneurysm as well as arterio-venous malformation (AVM), Moyamoya disease and stenosis of middle cerebral artery, meanwhile the MR angiography (MRA) and digital subtraction angiography (DSA) examination of these patients were also studied as comparison to the 3D-CTA results. The sensitivity and specificity on investigating intracranial aneurysm were similar with other reports so far. 3D-CTA was possible to identify the feeding artery, nidus and draining vein of AVM, although DSA showed higher detectability. Occlusion of internal carotid artery and post-operative anastomosis in Moyamoya disease were all demonstrated by 3D-CTA, however the Moyamoya collaterals were shown better on MRA. 3D-CTA revealed the site of stenosis of middle cerebral artery in all of our cases, but in general maximum intensity projection (MIP) images can provide more exact information about the degree of stenosis. Five years has passed since the emergence of spiral CT and utilizing of 3D-CTA in clinical applications. With the development of hard and soft ware in the near future, it is possible to delineate more small vessels by 3D-CTA. We predict that 3D-CTA would be widely used for detecting vasculature of the whole body, and may take the place of conventional angiography in many cases. (author)

  9. The accuracy and utility of contrast-enhanced MR angiography for localization of spinal dural arteriovenous fistulas: the Toronto experience

    Energy Technology Data Exchange (ETDEWEB)

    Lindenholz, Arjen [University Medical Center Groningen, Department of Neurosurgery AB71, PO Box 30001, Groningen (Netherlands); Toronto Western Hospital, Department of Medical Imaging, Division of Neuroradiology, Toronto, ON (Canada); TerBrugge, Karel G.; Farb, Richard I. [Toronto Western Hospital, Department of Medical Imaging, Division of Neuroradiology, Toronto, ON (Canada); Dijk, J.M.C. van [University Medical Center Groningen, Department of Neurosurgery AB71, PO Box 30001, Groningen (Netherlands)

    2014-11-15

    The purpose of this study was to determine the accuracy and utility of contrast-enhanced MR angiography (CE-MRA) in spinal dural arteriovenous fistulas (SDAVF). A retrospective analysis from 1999-2012 identified 70 patients clinically suspected of harboring a SDAVF. Each patient underwent consecutive conventional MR-imaging, CE-MRA, and digital subtraction angiography (DSA). The presence or absence of serpentine flow voids, T2-weighted hyperintensity, and cord enhancement were evaluated, as well as location of the fistula as predicted by CE-MRA. DSA was used as the reference standard. Of the 70 cases, 53 were determined to be a SDAVF, 10 cases were shown to be other forms of vascular malformation, and 7 were DSA-negative. On MRI, all reported cases of SDAVF showed serpentine flow voids (100 %). T2-weighted hyperintensity was seen in 48 of 50 cases (96 %), extending to the conus in 41 of 48 cases (85 %). Cord enhancement was seen in 38 of 41 cases (93 %). CE-MRA correctly localized the SDAVF in 43 of the 53 cases (81 %). CE-MRA is a useful non-invasive examination for the detection and localization of SDAVF. CE-MRA facilitates but does not replace DSA as confirmation of location, fistula type, and arterial detail, which are required before treatment. (orig.)

  10. Digital angiography in pulmonary embolism

    International Nuclear Information System (INIS)

    Bjoerk, L.

    1986-01-01

    Pulmonary digital subtraction angiography was diagnostic in 98.3% of patients with possible acute pulmonary embolism. The procedure was well tolerated even in severely ill patients. A large image intensifier made simultaneous imaging of both lungs possible reducing the number of contrast injections necessary. Small volumes of low iso-osmolar concentration of modern contrast media were used. There was no need for catherization of the pulmonary artery. Theoretical considerations and our limited experience indicate that this will reduce the number of complications compared with conventional pulmonary angiography. The procedure is rapidly performed and the diagnostic accuracy high. This makes digital subtraction angiography cost effective. Digital pulmonary angiography can be recommended as the primary diagnostic method in most patients with possible pulmonary embolism. (orig.)

  11. Infrared-laser-based fundus angiography

    Science.gov (United States)

    Klingbeil, Ulrich; Canter, Joseph M.; Lesiecki, Michael L.; Reichel, Elias

    1994-06-01

    Infrared fundus angiography, using the fluorescent dye indocyanine green (ICG), has shown great potential in delineating choroidal neovascularization (CNV) otherwise not detectable. A digital retinal imaging system containing a diode laser for illumination has been developed and optimized to perform high sensitivity ICG angiography. The system requires less power and generates less pseudo-fluorescence background than nonlaser devices. During clinical evaluation at three retinal centers more than 200 patients, the majority of which had age-related macular degeneration, were analyzed. Laser based ICG angiography was successful in outlining many of the ill-defined or obscure CNV as defined by fluorescein angiography. The procedure was not as successful with classic CNV. ICG angiograms were used to prepare and guide laser treatment.

  12. MR-angiography allows defining severity grades of cerebral vasospasm in an experimental double blood injection subarachnoid hemorrhage model in rats.

    Directory of Open Access Journals (Sweden)

    Vesna Malinova

    Full Text Available Magnetic resonance (MR imaging has been used for the detection of cerebral vasospasm (VSP related infarction in experimental subarachnoid hemorrhage (eSAH in rats. Conventional angiography is generally used to visualize VSP, which is an invasive technique with a possible increase in morbidity and mortality. In this study we evaluated the validity of MR-angiography (MRA in detecting VSP and its feasibility to define VSP severity grades after eSAH in rats.SAH was induced using the double-hemorrhage model in 12 rats. In two rats, saline solution was injected instead of blood (sham group. MR was performed on day 1, 2 and on day 5. T1-, T2-, T2*-weighted and time-of-flight MR sequences were applied, which were analyzed by two blinded neuroradiologists. Vessel narrowing of 25-50% was defined as mild, 50-75% as moderate and >75% as severe VSP.We performed a total of 34 MRAs in 14 rats. In 14 rats, MRA was performed on day 2 and day 5. In six rats MRA was additionally performed on day1 before the blood injection. A good visualization of cerebral vessels was possible in all cases. No VSP was seen in the sham group neither on day 2 nor on day 5. We found vasospasm on day 2 in 7 of the 14 rats (50% whereas all 7 rats had mild and one rat had additionally moderate and severe vasospasm in one vessel, respectively. On day 5 we found vasospasm in 8 of the 14 rats (60% whereas 4 rats had severe vasospasm, 1 rat had moderate vasospasm and 3 rats demonstrated mild vasospasm. In 4 of the 14 rats (30% an ischemic lesion was detected on day 5. Three of these rats had severe vasospasm and one rat had mild vasospasm. Severe vasospasm on day 5 was statistically significant correlated with the occurrence of ischemic lesions (Fisher's Exact test, OR 19.5, p = 0.03.MRA is a noninvasive diagnostic tool, which allows a good visualization of the cerebral vasculature and provides reproducible results concerning the detection of VSP and the differentiation into three severity

  13. Pulmonary MR angiography and perfusion imaging—A review of methods and applications

    Energy Technology Data Exchange (ETDEWEB)

    Johns, Christopher S.; Swift, Andrew J.; Hughes, Paul J.C. [University of Sheffield (United Kingdom); Ohno, Yoshiharu [Division of Functional and Diagnostic Imaging Research, Department of Radiology, KobeUniversity Graduate School of Medicine, Kobe, Hyogo (Japan); Schiebler, Mark [UW-Madison School of Medicine and Public Health, Madison, WI (United States); Wild, Jim M., E-mail: j.m.wild@sheffield.ac.uk [University of Sheffield (United Kingdom)

    2017-01-15

    Highlights: • This article represents an overview of the methodology and clinical applications of pulmonary MRA and perfusion imaging. • Both contrast enhanced and non-contrast enhanced metholodology for MRA and perfusion are covered. • The current clinical uses and future directions of MRA and MR perfusion are discussed. - Abstract: The pulmonary vasculature and its role in perfusion and gas exchange is an important consideration in many conditions of the lung and heart. Currently the mainstay of imaging of the vasculature and perfusion of the lungs lies with CT and nuclear medicine perfusion scans, both of which require ionizing radiation exposure. Improvements in MRI techniques have increased the use of MRI in pulmonary vascular imaging. Here we review MRI methods for imaging the pulmonary vasculature and pulmonary perfusion, both using contrast enhanced and non-contrast enhanced methodology. In many centres pulmonary MR angiography and dynamic contrast enhanced perfusion MRI are now well established in the routine workflow of patients particularly with pulmonary hypertension and thromboembolic disease. However, these imaging modalities offer exciting new directions for future research and clinical use in other respiratory diseases where consideration of pulmonary perfusion and gas exchange can provide insight in to pathophysiology.

  14. Pulmonary MR angiography and perfusion imaging—A review of methods and applications

    International Nuclear Information System (INIS)

    Johns, Christopher S.; Swift, Andrew J.; Hughes, Paul J.C.; Ohno, Yoshiharu; Schiebler, Mark; Wild, Jim M.

    2017-01-01

    Highlights: • This article represents an overview of the methodology and clinical applications of pulmonary MRA and perfusion imaging. • Both contrast enhanced and non-contrast enhanced metholodology for MRA and perfusion are covered. • The current clinical uses and future directions of MRA and MR perfusion are discussed. - Abstract: The pulmonary vasculature and its role in perfusion and gas exchange is an important consideration in many conditions of the lung and heart. Currently the mainstay of imaging of the vasculature and perfusion of the lungs lies with CT and nuclear medicine perfusion scans, both of which require ionizing radiation exposure. Improvements in MRI techniques have increased the use of MRI in pulmonary vascular imaging. Here we review MRI methods for imaging the pulmonary vasculature and pulmonary perfusion, both using contrast enhanced and non-contrast enhanced methodology. In many centres pulmonary MR angiography and dynamic contrast enhanced perfusion MRI are now well established in the routine workflow of patients particularly with pulmonary hypertension and thromboembolic disease. However, these imaging modalities offer exciting new directions for future research and clinical use in other respiratory diseases where consideration of pulmonary perfusion and gas exchange can provide insight in to pathophysiology.

  15. Angiography and the gastrointestinal bleeder

    International Nuclear Information System (INIS)

    Baum, S.

    1982-01-01

    The role of angiography in the diagnosis and treatment of gastrointestinal hemorrhage is discussed. Three categories of gastrointestinal bleeding are considered: upper gastrointestinal bleeding due to gastroesophageal varices, upper gastrointestinal bleeding of arterial or capillary origin, and lower gastrointestinal bleeding. The advantages and disadvantages of angiography are compared with those of radionuclide scanning and endoscopy or colonoscopy. It is anticipated that, as radionuclide scans are more widely employed, angiography will eventually be performed only in those patients with positive scans

  16. MR angiography of the body. Technique and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Neri, Emanuele [Pisa Univ. Radiodiagnostica 1 Universitaria (Italy). Diagnostic and Interventional Radiology Dept. of Oncology, Transplants, and Advanced Technologies in Medicine; Cosottini, Mirco [Pisa Univ. (Italy). Unit of Neuroradiology Dept. of Neurosciences; Caramella, Davide (eds.) [Pisa Univ. (Italy). Diagnostic and Interventional Radiology Dept. of Oncology, Transplants, and Advanced Technologies in Medicine

    2010-07-01

    Magnetic resonance angiography (MRA) continues to undergo exciting technological advances that are rapidly being translated into clinical practice. It also has evident advantages over other imaging modalities, including better patient safety compared with CT angiography and superior accuracy and contrast resolution compared with ultrasonography. With the aid of numerous high-quality illustrations, this book reviews the current role of MRA of the body. It is divided into three sections. The first section is devoted to issues relating to image acquisition technique and sequences. Individual chapters focus on flow-based MRA, contrast media, contrast-enhanced MRA, artifacts, and image processing. The second and principal section of the book addresses the clinical applications of MRA in various parts of the body, including the neck vessels, the spine, the thoracic aorta and pulmonary vessels, the heart and coronary arteries, the abdominal aorta and renal arteries, and peripheral vessels. The role of the blood pool contrast agents for the diagnosis and characterization of vascular disease is fully explored. The final section considers the role of MRA in patients undergoing liver or pancreas and kidney transplantation. This book will be an invaluable aid to all radiologists who work with MRA. (orig.)

  17. Benefit of cone-beam computed tomography angiography in acute management of angiographically undetectable ruptured arteriovenous malformations.

    Science.gov (United States)

    Rahal, Jason P; Malek, Adel M

    2013-10-01

    Ruptured arteriovenous malformations (AVMs) are a frequent cause of intracerebral hemorrhage (ICH). In some cases, compression from the associated hematoma in the acute setting can partially or completely occlude an AVM, making it invisible on conventional angiography techniques. The authors report on the successful use of cone-beam CT angiography (CBCT-A) to precisely identify the underlying angioarchitecture of ruptured AVMs that are not visible on conventional angiography. Three patients presented with ICH for which they underwent examination with CBCT-A in addition to digital subtraction angiography and other imaging modalities, including MR angiography and CT angiography. All patients underwent surgical evacuation due to mass effect from the hematoma. Clinical history, imaging studies, and surgical records were reviewed. Hematoma volumes were calculated. In all 3 cases, CBCT-A demonstrated detailed anatomy of an AVM where no lesion or just a suggestion of a draining vein had been seen with other imaging modalities. Magnetic resonance imaging demonstrated enhancement in 1 patient; CT angiography demonstrated a draining vein in 1 patient; 2D digital subtraction angiography and 3D rotational angiography demonstrated a suggestion of a draining vein in 2 cases and no finding in the third. In the 2 patients in whom CBCT-A was performed prior to surgery, the demonstrated AVM was successfully resected without evidence of a residual lesion. In the third patient, CBCT-A allowed precise targeting of the AVM nidus using Gamma Knife radiosurgery. Cone-beam CT angiography should be considered in the evaluation and subsequent treatment of ICH due to ruptured AVMs. In cases in which the associated hematoma compresses the AVM nidus, CBCT-A can have higher sensitivity and anatomical accuracy than traditional angiographic modalities, including digital subtraction angiography.

  18. MR angiography of the iliofemoral artery system

    International Nuclear Information System (INIS)

    Steffens, J.C.; Link, J.; Brinkmann, G.; Reuter, M.; Heller, M.

    1997-01-01

    During the last years, magnetic resonance angiography (MRA) has become a widely used modality for intracerebral and carotid artery imaging. Due to technical limitations, the clinical impact of MRA in the iliofemoral arteries has been rather poor. New developments in MRA like ECG-triggered sequences and the occurrence of contrast-enhanced MRA has overcome most of these limitations. Therefore, a major advance in clinical use of these diagnostic tools can be predicted. This paper discussed the advantages of ECG-gated 2D-Phase contrast, ECG-gated 2D-Time-of-Flight and contrast enhanced FLASH 3D angiography sequences from a clinical point of view. 2D-PC-MRA is a robust technique, which provides an overview of the iliofemoral artery system in less than 5 minutes. Limitations are the true 2D impression of the sequence and the partial venous overlay. 2D-TOF-MRA on the other hand is time consuming, however it enables 3D reconstruction and effective venous suppression can be applied. Contrast enhanced MRA as the third sequence discussed provides high resolution images in less than 30 sec. However contrast bolus timing might be a problem. In conclusion the authors suggest a combination of 2D-PC-MRA and additional 2D-TOF sequences at questionable vacular areas as the modality of choice, due to the fact, that MRA of the iliofemoral arteries is mostly only one step of a complete lower limb examination. Contrast MRA might become the method of choice in the future however problems with multiple contrast injections and upper limits of contrast dose have to be solved. (orig.) [de

  19. MR angiography in the follow-up of coiled cerebral aneurysms after treatment with Guglielmi detachable coils

    International Nuclear Information System (INIS)

    Nome, T.; Bakke, S. J.; Nakstad, P. H.

    2002-01-01

    Purpose: Intra-arterial digital subtraction angiography (DSA) has been considered the gold standard examination in the follow-up of patients treated with Guglielmi detachable coils (GDCs). However, DSA is an invasive and expensive investigation and results in exposure to ionising radiation to both patient and operator. The aim of this study was to compare MR angiography (MRA) with DSA with regard to patency of the occlusion of aneurysms following GDC treatment. Material and Methods: We performed 75 MRA and DSA examinations on 51 patients treated with GDCs. The examinations were performed 3-36 months after embolisation and the interval between MRA and DSA was less than 1 week. Hard copies of both studies were interpreted retrospectively and independently for residual flow within the aneurysm, residual aneurysmal neck, and parent and branch vessel flow. Results: Patency status of parent and branch vessel flow was correctly identified with MRA in all patients except 1. The sensitivity of MRA in revealing residual flow within the aneurysm was 97%. The specificity in ruling out residual flow within the aneurysm was 91%. Conclusion: MRA may replace DSA in the long-term follow-up of coiled cerebral aneurysms. The initial follow-up examination should, however, include both modalities

  20. Contrast-enhanced thoracic 3D-MR angiography in infants and children

    International Nuclear Information System (INIS)

    Holmqvist, C.; Larsson, E.M.; Staahlberg, F.; Laurin, S.

    2000-01-01

    To optimise breath-hold contrast-enhanced MR angiography (MRA) in infants and children with suspected congenital heart or thoracic vessel malformation. Thirty-nine children (median age 1 year) were examined, using five different ultrafast MRA sequences with a TR between 3.2 and 5.0 ms and the contrast agent meglumine gadoterate. A test injection was used to determine contrast travel time. Different parameters for contrast injection were evaluated. Signal-to-noise ratio (SNR) measurements were performed and image quality and injection timing were evaluated. MRA was successful in all patients and image quality was considered very good in 52%. Adequate SNR was achieved with no significant differences between the MR sequences. SNR decreased only 25 - 30% between subsequent scans. The mean contrast dose was 0.23 mmol/kg. The mean scan time was 12.5±3.8 s; the shorter scan times made dynamic examinations possible with high temporal resolution. Highest spatial resolution was obtained with TR 4.6/5.0 sequences. A contrast dose of 0.2 mmol/kg b.w. is recommended with an injection rate of 0.5 to 1.2 ml/s, depending on patient size and scan time. The scan delay time should equal the contrast travel time for optimal vessel enhancement. In the future, contrast-enhanced MRA may be a potential alternative to angiocardiography in infants and children

  1. MDCT angiography and transcatheter embolization in management ...

    African Journals Online (AJOL)

    Hassan Abdelsalam

    2015-12-18

    Dec 18, 2015 ... 14 patients did not have a MDCT and proceeded straight to angiography;. 6 of them showed active bleeding on angiography. Conclusion: MDCT is an excellent technique before angiography and embolization in cases with acute gastrointestinal bleeding. Transcatheter embolization is an effective tool for ...

  2. Digital subtraction angiography of the heart and lungs

    International Nuclear Information System (INIS)

    Moodie, D.S.; Yiannikas, J.

    1986-01-01

    This book contains 12 chapters. Some of the chapter titles are: Physical Principles of Cardiac Digital Subtraction Angiography, The Use of Intravenous Digital Subtraction Angiography in Evaluating Patients with Complex Congenital Heart Disease, Exercise Intravenous Digital Subtraction Angiograpny, Cardiomyopathic and Cardiac Neoplastic Disease, Digital Subtraction Angiography in the Catheterization Laboratory, and Cardiac Digital Subtraction Angiography - Future Directions

  3. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    International Nuclear Information System (INIS)

    Gao Sijia; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui; Zang Peizhuo; Shi Qiang; Wang Qiang; Liang Chuansheng; Xu Ke

    2009-01-01

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with χ 2 -test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show AVM not AVF. The

  4. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Gao Sijia [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)], E-mail: scarlettgao@126.com; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Zang Peizhuo [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Shi Qiang; Wang Qiang [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Liang Chuansheng [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Xu Ke [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)

    2009-07-15

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with {chi}{sup 2}-test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show

  5. Application of OCT angiography in ophthalmology

    Directory of Open Access Journals (Sweden)

    Ai-Ping Yang

    2017-11-01

    Full Text Available Optical coherence tomography angiography(OCTAis a new technology of angiography in recent years. In addition to the advantages of traditional OCT, it can observe blood flow in different retinal and choroidal segmentation slab. By using the pseudo-color, abnormal vascular structure can be distinguished from normal vascular structure of the retina. Dye injection is not needed with OCTA, which is different from fundus fluorescein angiography(FFAand indocyanine green angiography(ICGA. OCTA provides more and more accurate blood flow information. However, like other biometric technology, OCTA has its limitations and shortcomings. This review will analyze and summarize the operating principle of OCTA, its application in ophthalmology, as well as its advantages and limitations.

  6. Sequential gadolinium-enhanced magnetic resonance angiography of the aortoiliac and the femoropopliteal arteries with repetitive administration of low-dose contrast agent

    International Nuclear Information System (INIS)

    Ito, Koichiro; Kumazaki, Tatsuo

    2000-01-01

    To obtain a wide-range contrast MR angiography in a single examination, we performed two sequential administrations of low-dose (0.08 mmol/kg) gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) with three dimensional inversion recovery prepared fast spoiled gradient recalled acquisition in the steady-state (3D IR-fast SPGR) sequence. Signal characteristics of the sequence were estimated by computed simulations and an in vitro study. A clinical study of 19 examinations was done with sequential MR angiography of the aortoiliac and femoropopliteal arteries. Great signal differences were observed between the high and low Gd concentrations. Higher Gd concentrations generated significantly stronger signals. Greater signals were produced at TIs of longer than 150 msec than at shorter than 100 msec. In the clinical study, the arteries were visualized with sufficient signals even with a small amount of contrast agent. Contrast-to-noise ratios between the arteries and surrounding skeletal muscles or fat tissues ranged from 10.5±9.6 to 4.7±2.2 and 6.6±2.8 to -3.1±11.2, respectively. No venous enhancement was found with diluted contrast agent on the second MR angiography. Two consecutive contrast MR angiographies can be obtained with repetitive administration of low-dose contrast agent. (author)

  7. Sequential gadolinium-enhanced magnetic resonance angiography of the aortoiliac and the femoropopliteal arteries with repetitive administration of low-dose contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Koichiro [Nippon Medical School, Inba, Chiba (Japan). Chiba Hokusoh Hospital; Kumazaki, Tatsuo

    2000-12-01

    To obtain a wide-range contrast MR angiography in a single examination, we performed two sequential administrations of low-dose (0.08 mmol/kg) gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) with three dimensional inversion recovery prepared fast spoiled gradient recalled acquisition in the steady-state (3D IR-fast SPGR) sequence. Signal characteristics of the sequence were estimated by computed simulations and an in vitro study. A clinical study of 19 examinations was done with sequential MR angiography of the aortoiliac and femoropopliteal arteries. Great signal differences were observed between the high and low Gd concentrations. Higher Gd concentrations generated significantly stronger signals. Greater signals were produced at TIs of longer than 150 msec than at shorter than 100 msec. In the clinical study, the arteries were visualized with sufficient signals even with a small amount of contrast agent. Contrast-to-noise ratios between the arteries and surrounding skeletal muscles or fat tissues ranged from 10.5{+-}9.6 to 4.7{+-}2.2 and 6.6{+-}2.8 to -3.1{+-}11.2, respectively. No venous enhancement was found with diluted contrast agent on the second MR angiography. Two consecutive contrast MR angiographies can be obtained with repetitive administration of low-dose contrast agent. (author)

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... medical test that helps physicians diagnose and treat medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ...

  9. Angiography in non-traumatic brain haematoma. An analysis of 100 cases

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, P.D. [Sheffield Univ. (United Kingdom). Academic Dept. of Radiology; Beveridge, C.J.; Gholkar, A. [Newcastle General Hospital, Newcastle upon Tyne (United Kingdom). Dept. of Neuroradiology

    1997-09-01

    Purpose: The primary purpose of this project was to study the anatomical characteristics of intracerebral haematoma (ICH) in order to determine features that may negate the need for angiography in some patients. Material and Methods: The study was prospective and designed to investigate the underlying cause of non-traumatic ICH in 100 cases assessed by conventional angiography. Patients were excluded if there was a history of trauma or known pre-existing brain abnormality. All patients were examined with CT and angiography within 4 days of the ictus. Results: Ruptured aneurysms or arteriovenous malformations (AVMs) were diagnosed on the initial angiogram in 49% of cases: 27 AVMs and 22 aneurysms. One case of superior sagittal sinus thrombosis was also detected. Vascular abnormalities were found most frequently in the under-40 age group and in cases in which subarachnoid haemorrhage, intraventricular haemorrhage or extracerebral haematoma accompanied the ICH. The temporal lobe was the most frequent anatomical location (37%). When a temporal lobe haematoma extended into the Sylvian fissure from the inferior pole of the temporal lobe or when it was associated with subarachnoid haemorrhage, structural abnormalities were found in over 90% of cases. Conclusions: There are groups of patients with ICH in whom the CT features are highly suggestive of AVM or aneurysm rupture. If the initial angiography is negative in these cases, careful follow up by repeat angiography and/or MR imaging is essential. However, potentially treatable abnormalities cannot be excluded with certainty by the distribution of the haematoma on CT alone, even if there is a history of pre-existing hypertension. (orig.).

  10. Angiography in non-traumatic brain haematoma. An analysis of 100 cases

    International Nuclear Information System (INIS)

    Griffiths, P.D.; Beveridge, C.J.; Gholkar, A.

    1997-01-01

    Purpose: The primary purpose of this project was to study the anatomical characteristics of intracerebral haematoma (ICH) in order to determine features that may negate the need for angiography in some patients. Material and Methods: The study was prospective and designed to investigate the underlying cause of non-traumatic ICH in 100 cases assessed by conventional angiography. Patients were excluded if there was a history of trauma or known pre-existing brain abnormality. All patients were examined with CT and angiography within 4 days of the ictus. Results: Ruptured aneurysms or arteriovenous malformations (AVMs) were diagnosed on the initial angiogram in 49% of cases: 27 AVMs and 22 aneurysms. One case of superior sagittal sinus thrombosis was also detected. Vascular abnormalities were found most frequently in the under-40 age group and in cases in which subarachnoid haemorrhage, intraventricular haemorrhage or extracerebral haematoma accompanied the ICH. The temporal lobe was the most frequent anatomical location (37%). When a temporal lobe haematoma extended into the Sylvian fissure from the inferior pole of the temporal lobe or when it was associated with subarachnoid haemorrhage, structural abnormalities were found in over 90% of cases. Conclusions: There are groups of patients with ICH in whom the CT features are highly suggestive of AVM or aneurysm rupture. If the initial angiography is negative in these cases, careful follow up by repeat angiography and/or MR imaging is essential. However, potentially treatable abnormalities cannot be excluded with certainty by the distribution of the haematoma on CT alone, even if there is a history of pre-existing hypertension. (orig.)

  11. Feasibility study of 2D thick-slice MR digital subtraction angiography

    International Nuclear Information System (INIS)

    Ishimori, Yoshiyuki; Takeuchi, Miho; Higashimura, Kyouji; Komuro, Hiroyuki

    2000-01-01

    Conditions required to perform contrast MR digital subtraction angiography using a two-dimensional thick-slice high-speed gradient echo were investigated. The conditions in the phantom experiment included: slice profile, flip angle, imaging matrix, fat suppression, duration of IR pulse and frequency selectivity, flip angle of IR pulse and inversion time. Based on the results of the experiment, 2D thick-slice MRDSA was performed in volunteers. Under TR/TE=5.3-9/1.3-1.8 ms conditions, the requirements were a slice thick enough to include the target region, a flip angle of 10 degrees, and a phase matrix of 96 or more. Fat suppression was required for adipose-tissue-rich regions, such as the abdomen. The optimal conditions for applying the IR preparation pulse of the IR prepped fast gradient recalled echo as spectrally selective inversion recovery appeared to be: duration of IR pulse =20 ms, flip angle =100 degrees, and inversion time =40 ms. The authors concluded that it was feasible to perform 2D thick-slice MRDSA with time resolution within 1 second. (K.H.)

  12. Coronary CT angiography: Diagnostic value and clinical challenges.

    Science.gov (United States)

    Sabarudin, Akmal; Sun, Zhonghua

    2013-12-26

    Coronary computed tomography (CT) angiography has been increasingly used in the diagnosis of coronary artery disease due to improved spatial and temporal resolution with high diagnostic value being reported when compared to invasive coronary angiography. Diagnostic performance of coronary CT angiography has been significantly improved with the technological developments in multislice CT scanners from the early generation of 4-slice CT to the latest 320- slice CT scanners. Despite the promising diagnostic value, coronary CT angiography is still limited in some areas, such as inferior temporal resolution, motion-related artifacts and high false positive results due to severe calcification. The aim of this review is to present an overview of the technical developments of multislice CT and diagnostic value of coronary CT angiography in coronary artery disease based on different generations of multislice CT scanners. Prognostic value of coronary CT angiography in coronary artery disease is also discussed, while limitations and challenges of coronary CT angiography are highlighted.

  13. Superselective pseudo-continuous arterial spin labeling angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jensen-Kondering, Ulf [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Lindner, Thomas, E-mail: thomas.lindner@uksh.de [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Osch, Matthias J.P. van [C. J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden (Netherlands); Rohr, Axel; Jansen, Olav [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Helle, Michael [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Now with Philips GmbH Innovative Technologies, Research Laboratories, Hamburg (Germany)

    2015-09-15

    Highlights: • Superselective arterial spin labeling was capable of acquiring angiograms of individually selected arteries. • Image quality was similar compared with a routinely used time-of-flight angiography. • Superselective arterial spin labeling was utilized in patients with arterio-venous malformations and made it possible to visualize individual feeding vessels in a complete non-invasive way - Abstract: Purpose: To evaluate the utility of a novel non-contrast enhanced, vessel-selective magnetic resonance angiography (MRA) approach based on superselective pseudo-continuous arterial spin labeling (ASL) for the morphologic assessment of intracranial arteries when compared to a clinically used time-of-flight (TOF) MRA. Materials and methods: Three sets of selective ASL angiographies (right and left internal carotid artery, basilar artery) as well as one TOF data set were obtained from each of the five volunteers included in this study on a clinical 1.5T system. The depiction of arterial segments as well as their delineation was evaluated and independently analyzed by two radiologists. Additionally, the ASL angiography approach was performed in two patients suffering from arterio-venous malformations (AVM) in order to illustrate potential applications in a clinical setting. Results: In both angiography techniques, intracranial arteries and their segments (distal branches up to A5 segments of the anterior cerebral arteries, M8 segments of the middle cerebral arteries, and P5 segments of the posterior cerebral arteries) were continuously depicted with excellent inter-reader agreement (κ > 0.81). In AVM patients, reconstructed images of the TOF angiography presented similar information about the size and shape of the AVM as did superselective ASL angiography. In addition, the acquired ASL angiograms of selected vessels allowed assessing the blood supply of individually labeled arteries to the AVM which could also be confirmed by digital subtraction angiography

  14. Superselective pseudo-continuous arterial spin labeling angiography

    International Nuclear Information System (INIS)

    Jensen-Kondering, Ulf; Lindner, Thomas; Osch, Matthias J.P. van; Rohr, Axel; Jansen, Olav; Helle, Michael

    2015-01-01

    Highlights: • Superselective arterial spin labeling was capable of acquiring angiograms of individually selected arteries. • Image quality was similar compared with a routinely used time-of-flight angiography. • Superselective arterial spin labeling was utilized in patients with arterio-venous malformations and made it possible to visualize individual feeding vessels in a complete non-invasive way - Abstract: Purpose: To evaluate the utility of a novel non-contrast enhanced, vessel-selective magnetic resonance angiography (MRA) approach based on superselective pseudo-continuous arterial spin labeling (ASL) for the morphologic assessment of intracranial arteries when compared to a clinically used time-of-flight (TOF) MRA. Materials and methods: Three sets of selective ASL angiographies (right and left internal carotid artery, basilar artery) as well as one TOF data set were obtained from each of the five volunteers included in this study on a clinical 1.5T system. The depiction of arterial segments as well as their delineation was evaluated and independently analyzed by two radiologists. Additionally, the ASL angiography approach was performed in two patients suffering from arterio-venous malformations (AVM) in order to illustrate potential applications in a clinical setting. Results: In both angiography techniques, intracranial arteries and their segments (distal branches up to A5 segments of the anterior cerebral arteries, M8 segments of the middle cerebral arteries, and P5 segments of the posterior cerebral arteries) were continuously depicted with excellent inter-reader agreement (κ > 0.81). In AVM patients, reconstructed images of the TOF angiography presented similar information about the size and shape of the AVM as did superselective ASL angiography. In addition, the acquired ASL angiograms of selected vessels allowed assessing the blood supply of individually labeled arteries to the AVM which could also be confirmed by digital subtraction angiography

  15. An investigation of cerebral magnetic resonance angiography, 5

    International Nuclear Information System (INIS)

    Takeda, Sadanori; Sadamoto, Kazuhiko; Ohue, Shiro; Todo, Hirooki; Sakaki, Saburo.

    1992-01-01

    A number of studies of MR angiography (MRA) as a noninvasive screening method for vascular diseases have been reported recently. Almost all of them were investigated using high tesla magnets (1.5 tesla). We have been investigating three-dimensional MRA using a medium tesla (0.5 tesla) system (HITACHI G-50). The purpose of this study is to evaluate the usefulness of 3-D MRA for the screening of cerebral aneurysms. Twenty patients with 25 cerebral aneurysms were included in this study. The sizes of the aneurysms ranged from 2 to 35 mm. Twenty-three aneurysms were located on the anterior circulation, and 2 on the posterior circulation. MR angiography was performed with a gradient-echo sequence at a TR of 50 msec, a TE of 16 msec, and a flip angle of 25 degrees. The imaging volumes ranged in thickness from 48 to 64 mm, with 32 partitions. We used a sequence-subtraction technique composed of rephased and dephased sequences; it provides a good visualization of the main cerebral arteries. Cerebral aneurysms were detected on 3-D MRA in 23 lesions (92%). We consider that 0.5 tesla 3-D MRA could be useful for the screening of nonruptured aneurysms. (author)

  16. Intraarterial digital subtraction angiography after coronary bypass surgery - an alternative to coronary angiography

    International Nuclear Information System (INIS)

    Hauenstein, H.K.; Roeren, T.; Schlosser, V.; Urbani, B.

    1985-01-01

    Intraarterial digital subtraction angiography after coronary bypass surgery - an alternative to coronary angiography. Intraarterial DSA is a suitable method for early postoperative control of coronary artery bypass grafts. Small quantities of contrast media with low iodine content are injected into the aortic root. Investigations can be carried out with a routine fluoroscopic and digital equipment; additional cine-technique and analogue memory disc are not necessary. At an image rate of 3/s the bypass anastomoses can be exactly visualized in 75%, whereas diagnostic information was not sufficient in only 4% of all cases. The use of modern F-5-catheters and the nonselective injection make this method a less invasive alternative to coronary angiography. It is paticularly useful in evaluation of short- and long-term results. (orig.) [de

  17. Non-enhanced ECG-gated respiratory-triggered 3-D steady-state free-precession MR angiography with slab-selective inversion: initial experience in visualisation of renal arteries in free-breathing children without renal artery abnormality

    International Nuclear Information System (INIS)

    Klee, Dirk; Lanzman, Rotem Shlomo; Blondin, Dirk; Antoch, Gerald; Schaper, Joerg; Schmitt, Peter; Oh, Jun; Salgin, Burak; Mayatepek, Ertan

    2012-01-01

    ECG-gated non-enhanced balanced steady-state free precession (bSSFP) MR angiography requires neither breath-holding nor administration of contrast material. To investigate the image quality of free-breathing ECG-gated non-enhanced bSSFP MR angiography of renal arteries in children. Fourteen boys and seven girls (mean age, 9.7 years; range, 7 weeks-17 years) with no history of renovascular disease were included. MRI was performed at 1.5 T. Subjective image quality of axial and coronal maximum-intensity-projection reconstructions of four segments (I, aorta and renal artery ostium; II, main renal artery; III, segmental branches; IV, intrarenal vessels) was evaluated using a 4-point scale (4 = excellent, 3 = good, 2 = acceptable, 1 = non-diagnostic). Image quality was excellent for segments I (mean ± SD, 3.9 ± 0.3) and II (4.0 ± 0.1), good for segment III (3.4 ± 0.9) and acceptable for segment IV (2.3 ± 1.1). Mean image quality did not differ between sedated and non-sedated children. bSSFP MR angiography enables visualisation of renal arteries in children. (orig.)

  18. Diagnostic and interventional angiography of superior mesenteric artery

    Energy Technology Data Exchange (ETDEWEB)

    Simonetti, G; Urigo, F; Canalis, G C; Guazzaroni, M; Caboni, M; Rossi, P; Passariello, R

    1986-01-01

    The widespread diffusion of digital imaging progressivaly reduces the indications to conventional angiography in all vascular districts. On the contrary, angiography of mesenteric arteries still works as a valid complementary diagnostic tool in granulomatous and neoplastic lesions of ileum. Today, in selected patients, angiography is the first diagnostic approach to vascular ischemic and hemorrhagic pathology of ileum; timely resort to interventional angiography improve a dramatic prognosis. 70 refs.

  19. Hemifacial spasm; The value of vertebral angiography

    International Nuclear Information System (INIS)

    Yang, Hak Seok; Kim, Myung Soon; Han, Yong Pyo

    1992-01-01

    In order to evaluate the value of vertebral angiography in assesment of hemifacial spasm, We reviewed retrospectively the vertebral angiography of 28 patients (30 cases) with surgically proved hemifacial spasm but normal CT scans of posterior fossa. There were 9 males and 19 females. Angiography revealed vascular focus of hemifacial spasm located at anterior inferior cerebellar artery , posterior inferior cerebellar artery, and vertebral artery in 19, 9, and 2 cases respectively. Right side was involved in 20 cases. All involved vessels were elongated, tortuous, and dilated. In conclusion, vertebral angiography was valuable in evaluating hemifacial spasm of vascular origin in the posterior fossa

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... to your primary care or referring physician , who will discuss the results with you. top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need ...

  1. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  2. Digital subtraction angiography for breast cancer

    International Nuclear Information System (INIS)

    Tsurumi, Kiyohiko; Okuyama, Nobuo

    1987-01-01

    We performed digital subtraction angiography (DSA) on 42 patients with breast diseases to investigate its efficiency. As a result we came to the following conclusions: 1. The sensitivity was well evaluated in intraarterial digital subtraction angiography (IA-DSA) of breast. 2. IA-DSA could diagnose difficult cases like cancer which had undergone augmentation mammoplasty, or like Paget's disease and others. 3. DSA was a safe examination method. 4. The sensitivity of IA-DSA of breast cancer is superior to intravenous digital subtraction angiography (IV-DSA). (author)

  3. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography ...

  4. Accuracy of 3 T MR angiography in vertebral artery stenosis and coincidence with other cerebrovascular stenoses

    International Nuclear Information System (INIS)

    Choi, Hyun Seok; Kim, Dong Ik; Kim, Dong Joon; Kim, Jinna; Kim, Eun Soo; Lee, Seung-Koo

    2010-01-01

    Ostium of vertebral artery (VA) is a common site of pseudostenosis on contrast-enhanced MR angiography (CE-MRA). The purpose of this study was to determine the diagnostic accuracy of CE-MRA at 3 T in the evaluation of ostial stenosis of VA and to find associated coincidental stenoses using logistic regression analysis. One hundred and thirty-five VA ostial regions from 72 patients who received CE-MRA of neck vessels, intracranial time of flight (TOF) MRA, and digital subtraction angiography (DSA) were retrospectively reviewed. The sensitivity and specificity of the CE-MRA in detection of ostial stenosis were calculated with reference standard of DSA. Ostial stenosis on MRA was correlated with coincidental lesions in intracranial and cervical arteries by logistic regression analysis. The sensitivity and specificity of the CE-MRA were 100% and 80.4% for detection of significant stenosis. In case of significant stenoses, CE-MRA showed a tendency of overestimation with a false-positive rate of 52.5%. Logistic regression analysis showed that the stenoses of middle cerebral artery (MCA) on TOF MRA was associated with significant stenoses of VA ostia (OR = 5.84, 95% confidence intervals 1.41-24.17). CE-MRA is sensitive in detection of VA ostial stenosis although it has high false-positive rate. True positive ostial stenosis should be considered in cases of coincidental stenoses of MCA on TOF MRA. (orig.)

  5. Latest techniques in head and neck CT angiography

    International Nuclear Information System (INIS)

    Schuknecht, B.

    2004-01-01

    Continuous evolution of multi row CT is increasingly making CT angiography a viable imaging modality for assessment of the supraaortic and intracranial vessels as an anatomically and functionally coherent vascular system. Extended non-invasive examinations with reduced contrast volume have become feasible with the availability of 16 and 64 row MDCT scanners. Prerequisites to obtain high resolution CT angiographies of the head and neck vessels with superior detail include the administration of low contrast volume, high contrast density (400 mg I/ml) contrast media, adequate timing and data acquisition, optimal flow rate (4 ml/s) and saline flushing. Non-invasiveness, delineation of vessel calcification, virtual independence from hemodynamic conditions, and the ability to provide quantification without needing to correct for magnification are all attributes that favour CT angiography over digital subtraction angiography and to some extent even magnetic resonance angiography as an alternative non-invasive technique. CT angiography is established as a modality of choice for the assessment of patients with acute stroke and chronic steno-occlusive disease. CT angiography may indicate the presence of extra- or intracranial acute vessel occlusion and dissection, predisposing atherosclerotic steno-occlusive disease and thus indicate thrombo-embolism or local appositional thrombosis as the principle pathogenic factor. CT angiography is used to assess anatomy, and to depict the presence, location and extent of calcified and non-calcified plaque as a cause of high grade stenosis. Despite relatively limited sensitivity CT angiography is indicated for suspected or confirmed aneurysms that demand further verification of their presence, geometry, or relationship to parent artery branches and osseous anatomic landmarks. Low volume high density contrast media have substantially increased the ability of CT angiography to depict small aneurysms, small branches, and collateral vessels

  6. Angiography in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Zeitler, E

    1982-04-05

    We report on the cooperative possibilities the radiologist has as to diagnosis and therapy of portal hypertension. The catheter angiography allows to make a differentiation between pre- and intrahepatic bloc and the localization of bleeding esophagus varices. Only after all endoscopic measures with sclerotherapy and Laser coagulation have failed, catheter angiography will be carried out as a therapeutic measure. The future development, however, will give the opportunity to a series of therapeutic attempts on the field of interventional radiology.

  7. Magnetic resonance angiography for the head and neck region

    International Nuclear Information System (INIS)

    Aschenbach, R.; Esser, D.

    2004-01-01

    Magnetic resonance angiography is a noninvasive method in vascular imaging using noncontrast- enhanced and contrast-enhanced techniques. The contrast media used in contrast- enhanced magnetic resonance angiography are different from the X-ray contrast media and do not affect the thyroid gland or renal function. In detecting hypervascularized lesions in the head and neck, contrast-enhanced magnetic resonance angiography is the method of choice, which provides an acceptable quality in comparison to digital subtraction angiography. Future developments in magnetic resonance imaging techniques will cause a wider use of magnetic resonance angiography, especially in head and neck imaging. Digital subtraction angiography should therefore only be used in problem cases and for preoperative embolization [de

  8. Comparison of CO2 DSA and conventional angiography using non-ionic contrast media in lower extremity angiography

    International Nuclear Information System (INIS)

    Kim, Jae Kyu; Park, Sung Jae; Koh, Seok Wan; Seo, Jeong Jin; Kang, Heoung Keun; Chung, Hyon De

    1994-01-01

    The purpose of this study is to compare CO 2 DSA and nonionic contrast media angiography in respect to the quality of the opacification of collaterals and incidence of side-effects in peripheral occlusive arterial disease. Sixteen patients who were suspected to have peripheral occlusive arterial disease were performed angiography with nonionic contrast media and CO 2 at the same location with the same catheter. The causes of the lesions were atherosclerosis(n=7) and Buerger's disease(n=9). CO 2 DSA was compared with nonionic contrast media angiography in respect to the quality of image in the diagnosis of the lesions, opacifications of collaterals and side-effects. In atherosclerosis; quality of the images of CO 2 DSA was same as that of nonionic contrast media angiography in 6 patients and was poor in 1 patient; opacifications of collaterals of CO 2 DSA were same as that of nonionic contrast media angiography in 5 patients and was poor in 2 patients. In Buerger's disease; quality of the images of CO 2 DSA was same as that of nonionic contrast media angiography in 2 patients and was poor in 7 patients; opacifications of collaterals of CO 2 DSA were same as that of nonionic contrast media angiography in 1 patient and was poor in 8 patients. Leg pain was the only side-effect after CO 2 injection occurring in 4 out of 16 patients. CO 2 could be used as safe contrast media in patient with risk factors for nonionic contrast media and for diagnosis of the atherosclerosis in lower extremity. For the procedures such as vascular intervention requiring large amount of contrast media CO 2 could effectively replace nonionic contrast media

  9. Videodensitometric quantitative angiography after coronary balloon angioplasty, compared to edge-detection quantitative angiography and intracoronary ultrasound imaging

    NARCIS (Netherlands)

    Peters, R. J.; Kok, W. E.; Pasterkamp, G.; von Birgelen, C.; Prins, M. [=Martin H.; Serruys, P. W.

    2000-01-01

    AIMS: To assess the value of videodensitometric quantification of the coronary lumen after angioplasty by comparison to two other techniques of coronary artery lumen quantification. METHODS AND RESULTS: Videodensitometric quantitative angiography, edge detection quantitative angiography and 30 MHz

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... congenital abnormalities in blood vessels, especially arteries in children (e.g., malformations in the heart or other ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an artery ... examined, a contrast material is injected through the tube and images are captured using a small dose ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... accurate pictures of the blood vessels and may eliminate the need for surgery. Tell your doctor if ... are the benefits vs. risks? Benefits Angiography may eliminate the need for surgery. If surgery remains necessary, ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... angiogram may be performed in less than an hour; however, it may last several hours. top of ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... a tendency to bleed. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... diagnosis and treatment in a single procedure. An example is finding an area of severe arterial narrowing, ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... possible to combine diagnosis and treatment in a single procedure. Catheter angiography produces very detailed, clear and ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... blood flow to the brain and cause a stroke. identify a small aneurysm or arteriovenous malformation (abnormal ... you. top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need for ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... iodine. If angiography is essential, a variety of methods is used to decrease risk of allergy: You ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. Catheter angiography ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. An example ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... examine blood vessels in key areas of the body for abnormalities such as aneurysms and disease such ... to produce pictures of blood vessels in the body. Angiography is performed using: x-rays with catheters ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... rare, and radiology departments are well-equipped to deal with them. There is a small risk that ... standard x-ray contrast. Catheter angiography should be done very cautiously—if at all—in patients who ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... possible charges you will incur. Web page review process: This Web page is reviewed regularly by a ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... few millimeters) in the skin where the catheter can be inserted into an artery. The catheter is ... need for surgery. If surgery remains necessary, it can be performed more accurately. Catheter angiography presents a ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... 20 minutes (or by using a special closure device). When the examination is complete, you may be ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... rays ). top of page What are some common uses of the procedure? Catheter angiography is used to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... far outweighs the risk. If you have a history of allergy to x-ray contrast material, your ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... and x-rays. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material to examine ... removable dental appliances, eye glasses and any metal objects or clothing that might interfere with the x- ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... American College of Radiology (ACR) and the European Society of Urogenital Radiology note that the available data ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... most cases, the kidneys will regain their normal function within five to seven days. Rarely, the catheter ... limitations of Catheter Angiography? Patients with impaired kidney function, especially those who also have diabetes, are not ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... in key areas of the body, including the: brain neck heart chest abdomen (such as the kidneys ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... The video is produced by the x-ray machine and a detector that is suspended over a ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need for surgery. ... in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... serious allergic reaction to contrast materials that contain iodine is extremely rare, and radiology departments are well- ... having a reaction to contrast materials that contain iodine. If angiography is essential, a variety of methods ...

  16. Angiography in portal hypertension

    International Nuclear Information System (INIS)

    Zeitler, E.

    1982-01-01

    We report on the cooperative possibilities the radiologist has as to diagnosis and therapy of portal hypertension. The catheter angiography allows to make a differentiation between pre- and intrahepatic bloc and the localization of bleeding esophagus varices. Only after all endoscopic measures with sclerotherapy and Laser coagulation have failed, catheter angiography will be carried out as a therapeutic measure. The future development, however, will give the opportunity to a series of therapeutic attempts on the field of interventional radiology. (orig.) [de

  17. A novel MR contrast agent for angiography and perfusion: Hyperpolarized water

    DEFF Research Database (Denmark)

    Lipsø, Hans Kasper Wigh

    , hyperpolarized by dissolution Dynamic Nuclear Polarization (d-DNP), can be applied as an MRI contrast agent for angiography and perfusion. The first part of the project focuses on development of a protocol for production of large samples of hyperpolarized protons in D2O. The samples are polarized and dissolved...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... Contrast Materials CT Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  20. Comparison of 3T and 7T susceptibility-weighted angiography of the substantia nigra in diagnosing Parkinson disease.

    Science.gov (United States)

    Cosottini, M; Frosini, D; Pesaresi, I; Donatelli, G; Cecchi, P; Costagli, M; Biagi, L; Ceravolo, R; Bonuccelli, U; Tosetti, M

    2015-03-01

    Standard neuroimaging fails in defining the anatomy of the substantia nigra and has a marginal role in the diagnosis of Parkinson disease. Recently 7T MR target imaging of the substantia nigra has been useful in diagnosing Parkinson disease. We performed a comparative study to evaluate whether susceptibility-weighted angiography can diagnose Parkinson disease with a 3T scanner. Fourteen patients with Parkinson disease and 13 healthy subjects underwent MR imaging examination at 3T and 7T by using susceptibility-weighted angiography. Two expert blinded observers and 1 neuroradiology fellow evaluated the 3T and 7T images of the sample to identify substantia nigra abnormalities indicative of Parkinson disease. Diagnostic accuracy and intra- and interobserver agreement were calculated separately for 3T and 7T acquisitions. Susceptibility-weighted angiography 7T MR imaging can diagnose Parkinson disease with a mean sensitivity of 93%, specificity of 100%, and diagnostic accuracy of 96%. 3T MR imaging diagnosed Parkinson disease with a mean sensitivity of 79%, specificity of 94%, and diagnostic accuracy of 86%. Intraobserver and interobserver agreement was excellent at 7T. At 3T, intraobserver agreement was excellent for experts, and interobserver agreement ranged between good and excellent. The less expert reader obtained a diagnostic accuracy of 89% at 3T. Susceptibility-weighted angiography images obtained at 3T and 7T differentiate controls from patients with Parkinson disease with a higher diagnostic accuracy at 7T. The capability of 3T in diagnosing Parkinson disease might encourage its use in clinical practice. The use of the more accurate 7T should be supported by a dedicated cost-effectiveness study. © 2015 by American Journal of Neuroradiology.

  1. Inversion prepared coronary MR angiography: direct visualization of coronary blood flow

    International Nuclear Information System (INIS)

    Katoh, M.; Spuentrup, E.; Buecker, A.; Guenther, R.W.; Stuber, M.; Manning, W.J.; Botnar, R.M.

    2005-01-01

    Purpose: visualization of coronary blood flow by means of a slice-selective inversion pre-pulse in concert with bright-blood coronary MRA. Materials and methods: coronary magnetic resonance angiography (MRA) of the right coronary artery (RCA) was performed in eight healthy adult subjects on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Medical Systems, Best, NL) using a free-breathing navigator-gated and cardiac-triggered 3D steady-state free-precession (SSFP) sequence with radial k-space sampling. Imaging was performed with and without a slice-selective inversion pre-pulse, which was positioned along the main axis of the coronary artery but perpendicular to the imaging volume. Objective image quality parameters such as SNR, CNR, maximal visible vessel length, and vessel border definition were analyzed. Results: in contrast to conventional bright-blood 3D coronary MRA, the selective inversion pre-pulse provided a direct measure of coronary blood flow. In addition, CNR between the RCA and right ventricular blood pool was increased and the vessels had a tendency towards better delineation. Blood SNR and CNR between right coronary blood and epicardial fat were comparable in both sequences. (orig.)

  2. The diagnostic value of three-dimensional dynamic contrast-enhanced MR angiography for intracranial aneurysms

    International Nuclear Information System (INIS)

    Liu Qi; Lu Jianping; Wang Fei; Wang Li; Tian Jianming; Jin Aiguo; Zeng Hao

    2003-01-01

    Objective: To assess the clinical value of three-dimensional dynamic contrast-enhanced MR angiography (3D DCE-MRA) in the detection for intracranial aneurysm. Methods: 3D DCE-MRA was performed in 54 patients highly suspected with intracranial aneurysms. Then conventional digital subtraction angiography (DSA) and feasible endovascular treatment were performed simultaneously. A three-dimensional fast imaging with steady state precession (3D FISP) was used for 3D DCE-MRA(Gd-DTPA dose, 0.2 mmol per kilogram for body weight; acquisition time, 10 seconds). The source images were subtracted from mask images and transferred to computer workstation. All images were subsequently post-processed using three-dimensional reconstruction. 3D DCE-MRA images and DSA images were compared for demonstration of the aneurysm, its neck, and relationship with parent artery, and the usefulness for endovascular treatment was evaluated. Results: There were 39 cases with 45 intracranial aneurysms. The sensitivity, specificity, and accuracy of 3D DCE-MRA were 96%, 73% and 90%, respectively. Aneurysm and its neck depiction at 3D DCE-MRA was significantly better than that at DSA, especially for aneurysms adjacent to the cavernous sinus and near the PICA of vertebral artery. 3D DEC-MRA could guide neurosurgeons to the desired DSA projection, and helped them make plan for interventional or surgical treatment in advance. But the diagnosis should be very carefully made for small aneurysms located in the periphery and the arterial bifurcation. Conclusion: 3D DEC-MRA is a fast, noninvasive and efficient technique for diagnosing intracranial aneurysms. Its three dimensional information is helpful for DSA demonstration and treatment planning. Any uncertain diagnosis requires DSA confirmation

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... with you. top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need for surgery. If ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  4. The potential for neurovascular intravenous angiography using K-edge digital subtraction angiography

    International Nuclear Information System (INIS)

    Schueltke, E.; Fiedler, S.; Kelly, M.; Griebel, R.; Juurlink, B.; LeDuc, G.; Esteve, F.; Le Bas, J.-F.; Renier, M.; Nemoz, C.; Meguro, K.

    2005-01-01

    Background: Catheterization of small-caliber blood vessels in the central nervous system can be extremely challenging. Alternatively, intravenous (i.v.) administration of contrast agent is minimally invasive and therefore carries a much lower risk for the patient. With conventional X-ray equipment, volumes of contrast agent that could be safely administered to the patient do not allow acquisition of high-quality images after i.v. injection, because the contrast bolus is extremely diluted by passage through the heart. However, synchrotron-based digital K-edge subtraction angiography does allow acquisition of high-quality images after i.v. administration of relatively small doses of contrast agent. Materials and methods: Eight adult male New Zealand rabbits were used for our experiments. Animals were submitted to both angiography with conventional X-ray equipment and synchrotron-based digital subtraction angiography. Results: With conventional X-ray equipment, no contrast was seen in either cerebral or spinal blood vessels after i.v. injection of iodinated contrast agent. However, using K-edge digital subtraction angiography, as little as 1 ml iodinated contrast agent, when administered as i.v. bolus, yielded images of small-caliber blood vessels in the central nervous system (both brain and spinal cord). Conclusions: If it would be possible to image blood vessels of the same diameter in the central nervous system of human patients, the synchrotron-based technique could yield high-quality images at a significantly lower risk for the patient than conventional X-ray imaging. Images could be acquired where catheterization of feeding blood vessels has proven impossible

  5. Magnetic resonance angiography for patients with positional vertigo

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Toru; Tominaga, Satoru; Fujiki, Hiroya (Takarazuka City Hospital, Hyogo (Japan)); Kumoi, Takeo

    1993-11-01

    Magnetic resonance angiography (MRA) can image the blood vessels without invasion. Using MRA, we studied the vascular morphology of the vertebral artery in patients with positional nystagmus and vertigo. Fifteen patients without vestibular disorder such as benign positional vertigo were examined. Six cases underwent conventional vertebral angiography, including digital subtraction angiography (DSA) for comparison with MRA. In all cases. we observed the vertebral artery from the bifurcation to the basilar artery with MRA. In 12 cases, abnormal findings of elongation, bending, narrowing or obstruction of the vertebral artery were found. In five cases, arterial compression and elongation increased in association with head rotation. A difference in the vessel diameter on each side was observed in 4 cases. Accordingly, some abnormal vessels were found in 14 of 15 cases in our study. This rate was very close to previous results obtained with conventional angiography. In two cases, MRA findings differed from conventional angiography due to peculiar artifacts of MRA. Therefore, MRA may be the first choice for the patients with vertigo, followed by conventional angiography, if necessary. (author).

  6. Magnetic resonance angiography for patients with positional vertigo

    International Nuclear Information System (INIS)

    Seo, Toru; Tominaga, Satoru; Fujiki, Hiroya; Kumoi, Takeo.

    1993-01-01

    Magnetic resonance angiography (MRA) can image the blood vessels without invasion. Using MRA, we studied the vascular morphology of the vertebral artery in patients with positional nystagmus and vertigo. Fifteen patients without vestibular disorder such as benign positional vertigo were examined. Six cases underwent conventional vertebral angiography, including digital subtraction angiography (DSA) for comparison with MRA. In all cases. we observed the vertebral artery from the bifurcation to the basilar artery with MRA. In 12 cases, abnormal findings of elongation, bending, narrowing or obstruction of the vertebral artery were found. In five cases, arterial compression and elongation increased in association with head rotation. A difference in the vessel diameter on each side was observed in 4 cases. Accordingly, some abnormal vessels were found in 14 of 15 cases in our study. This rate was very close to previous results obtained with conventional angiography. In two cases, MRA findings differed from conventional angiography due to peculiar artifacts of MRA. Therefore, MRA may be the first choice for the patients with vertigo, followed by conventional angiography, if necessary. (author)

  7. On the system of cine-angiography

    International Nuclear Information System (INIS)

    Wakamatsu, Koji; Togi, Hideaki; Yokoyama, Hironori

    1979-01-01

    National Institute of Circulatory Disease Centre have four angiography apparatuses which deal with more than 80 cases of cerebral blood vessel and 100 cases of heart blood vessel each month. Most of the angiography is cine-photography. Five more angiography apparatuses are expected to be operated in operation and RI examination rooms in the future. The problems on cine-angiography system were discussed as follows: (1) The proper dose must be chosen in order to obtain good quality of cine-images. (2) The cine resolution depends much on dose. (3) The lower X-ray tube voltage can give better contrast. (4) Suitable capacity for an X-ray tube is over 60 kW at 2 sec rating. (5) Cine-autophotography requires rapid response and a circuit for lock. (6) Influence of side scattering can be solved by a blanking circuit in biplane cine-photography. (7) Self-developing is desirable to improve the quality of cine-images. (Kobatake, H.)

  8. Automatic registration using implicit shape representations: applications in intraoperative 3D rotational angiography to preoperative CTA registration

    International Nuclear Information System (INIS)

    Subramanian, Navneeth; Pichon, Eric; Solomon, Stephen B.

    2009-01-01

    A solution for automatic registration of 3D rotational angiography (XA) to CT/MR of the liver. Targeted for use in treatment planning of liver interventions. A shape-based approach to registration is proposed that does not require specification of landmarks nor is it prone to local minima like purely intensity-based registration methods. Through the use of vessel characteristics, accurate registration is possible even in the presence of deformations induced by catheters and respiratory motion. Registration was performed on eight pairs of multiphase CT angiography and 3D rotational digital angiography datasets. Quantitative validation of the registration accuracy using vessel landmarks was performed on these datasets. The validation study showed that the method has a registration error of 9.41±4.13 mm. In addition, the computation time is well below 60 s making it attractive for clinical application. A new method for fully automatic 3DXA to CT/MR image registration was developed and found to be efficient and accurate using clinically realistic datasets. (orig.)

  9. Comparison of spiral CT angiography with conventional digital subtraction angiography in the evaluation of renal transplant donors: a pilot study

    International Nuclear Information System (INIS)

    Chu, C.; Young, N.; Lau, H.

    2001-01-01

    Conventional digital subtraction renal arteriography (IA-DSA) has been traditionally used as the preoperative imaging modality for assessment of renal vascular anatomy for renal transplant donors. This study evaluates the potential use of spiral CT angiography in replacing IA-DSA in the preoperative assessment of this group of patients. Seven patients underwent both spiral CT angiography and IA-DSA between October 1997 and April 1998. It is concluded that spiral CT angiography can demonstrate the number, length and location of renal arteries and it is suggested that spiral CT angiography can potentially replace IA-DSA in the preoperative assessment of renal donors. Copyright (2001) Blackwell Science Pty Ltd

  10. Complications with Outpatient Angiography and Interventional Procedures

    International Nuclear Information System (INIS)

    Young, Noel; Chi, Ka-Kit; Ajaka, Joe; McKay, Lesa; O'Neill, Diane; Wong, Kai Ping

    2002-01-01

    Purpose: To prospectively identify the complications, and rates of complication, in outpatient angiography and interventional procedures. Methods: There were 1050 consecutive patients, 646 men and 404 women, aged 17-89 years, with a total of 1239 procedures studied in a 2-year period, 1997 to 1999. Results: There were 560 cases of aorto-femoral angiography,resulting in 124 complications (22%), with pain or hematoma in 110.There were 206 cases of neck and cerebral angiography, resulting in 51 complications (25%), with pain and hematoma in 34, transient ischemic attack in 2 and cerebrovascular accident in 1. There were 197 interfentional procedures, with 177 being balloon dilatations, resulting in 68 complications (35%), with 2 having hematomas and 1 having hematoma/abscess requiring active treatment. There were 276 cases having various 'other' procedures (e.g., renal angiography),resulting in 65 complications (24%), with pain and hematoma in 61. No procedure-related death occurred. Eighteen cases (1.5%) had significant complications, with contrast allergy in eight. Conclusion: Outpatient angiography and intervention are relatively safe, with low significant complication rates

  11. Sensitivity encoding (SENSE) for high spatial resolution time-or-flight MR angiography of the intracranial arteries at 3.0 T

    International Nuclear Information System (INIS)

    Willinek, W.A.; Falkenhausen, M. von; Born, M.; Hadizadeh, D.; Manka, C.; Textor, H.J.; Schild, H.H.; Kuhl, C.K.

    2004-01-01

    Methods: In a prospective study TOF MR angiography of the circle of Willis was performed with SENSE in 24 patients on a clinical whole body 3.0 T MR system (Intera, Philips Medical Systems, NL). In the SENSE (S-MRA), a SENSE factor of 2.5 was used to shorten acquisition time and to increase the anatomic coverage (5:12 min.; 150 slices). A matrix of 832x 572 was acquired and reconstructed to 1024 yielding a non-zerofilled voxel size of 0.30x0.44x1.00mm 3 (0.13 mm 3 ). Two readers were asked to review the images regarding the presence of vascular disease, and to rate, in consensus, the quality of the angiograms on a 5-point scale (5 = excellent through 1 = non-diagnostic). Results were compared with the results in 15 subjects who underwent intracranial TOF MRA at 3.0 T without SENSE (NS-MRA: acquisition time, 7:57 min.; 100 slices). Digital subtraction angiography (DSA) served as standard of reference in the 4/24 patients in whom vascular disease was identified. Results: S-MRA at 3.0 T was judged to provide image quality that was adequate for diagnosis or better in 24/24. Median score of image quality of S-MRA and NS-MRA were 5 and 5, respectively. In the 4 patients with DSA correlation, a total of 8 pathologic findings (7 steno-occlusive diseases, 1 aneurysm) were correctly identified on S-MRA. (orig.) [de

  12. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography.

    Science.gov (United States)

    Kadziela, Jacek; Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure.

  13. Evaluation of paraclinoid aneurysm by using contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Tsuboi, Toshiyuki; Takahashi, Kazuya; Date, Isao; Mandai, Shinya; Kinugasa, Kazushi; Nishimoto, Akira

    2004-01-01

    Juxta-dural ring aneurysms of the internal carotid artery have different clinical courses and risks of subarachnoid hemorrhage (SAH) depending upon their positions in the intradural or extradural spaces. The goal of this study was to localize such aneurysms using contrast enhanced-MR Angiography (CE-MRA). CE-MRA studies were performed in 18 patients with juxta-dural ring aneurysms using three-dimensional time-of-flight spoiled gradient-recalled acquisition in the steady state (3D-TOF-SPGR) sequence. Imaging parameters were as follows: 33/3.4/1 (repetition time/echo time/number of excitation (TR/TE/NEX)), flip angle 25 deg, 256 x 192 matrix, 0.8-mm slice thickness, 60 sections in total (one slab), 180-mm field of view, with no magnetization transfer contrast (MTC), superior saturation (S sat) pulse, total imaging time 6 minutes 53 seconds. We evaluated both the source images of CE-MRA and multiplanar reconstruction (MPR) images. When the hyperintensity of the aneurysm was located within the hyperintensity of the contrast-enhanced cavernous sinus, we diagnosed the lesion as an intracavernous, ''extradural'' aneurysm. In addition, we compared CE-MRA with operative findings. Seven patients out of 18 were treated surgically. In all, MRI findings corresponded well with the operative findings. We believe CE-MRA and its MPR images using 3D-TOF-SPGR sequence is a useful technique to evaluate juxta-dural ring aneurysms. (author)

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... the equipment look like? How does the procedure work? How is the ... and treat medical conditions. Angiography uses one of three imaging technologies and, ...

  15. Gas enhanced magnetic resonance angiography of the cerebrum using carbon dioxide and oxygen - preliminary results

    DEFF Research Database (Denmark)

    Pedersen, Mads Møller; Hansen, Kristoffer Lindskov; Ohlhues, Anders

    Purpose/introduction Standard imaging of the cerebral arteries is performed using intravenous contrast in CT angiography and x-ray angiography. Magnetic resonance angiography (MRA) of the cerebral arteries using intravenous contrast media does not perform well. Contrast in the venous bed...... and Methods Two healthy volunteers were scanned during inhalation of three different gas mixtures: Gas I (air), Gas II (5% CO2, 21 % O2, 74 % N2), Gas III (5% CO2, 95% O2). For each gas mixture a time of flight (TOF) series on the cerebral arteries was performed. Following each TOF series an ECG-gated phase...... contrast sequence was performed to calculate volume flow in the common carotid arteries. MRA data was acquired with a 1.5 T Siemens VISION MR-system (SIEMENS Medical Systems, Germany) using a standard circularly polarized head coil. Reconstructed images of TOF series and volume flow measurements were...

  16. MR imaging of persistent primitive trigeminal artery

    International Nuclear Information System (INIS)

    Ashikaga, Ryuichiro; Araki, Yutaka; Ono, Yukihiko; Ishida, Osamu; Mabuchi, Nobuhisa.

    1997-01-01

    The persistent trigeminal artery is the most common anomaly of the primitive carotid-vertebrobasilar anastomoses. We reviewed MR images and MR angiographies of 11 patients with primitive trigeminal artery. In 8 of the 11 cases, PTA were identified with conventional long TR spin-echo images. In 8 of 11 cases, a hypoplastic basilar trunk associated with PTA was seen on both MR images and MR angiographies. In 7 of 11 cases, a hypoplasia or agenesis of the ipsilateral posterior communicating artery was seen on MR angiographies. (author)

  17. A comparison between magnetic resonance angiography at 3 teslas (time-of-flight and contrast-enhanced and flat-panel digital subtraction angiography in the assessment of embolized brain aneurysms

    Directory of Open Access Journals (Sweden)

    Guilherme S. Nakiri

    2011-01-01

    Full Text Available PURPOSE: To compare the time-of-flight and contrast-enhanced- magnetic resonance angiography techniques in a 3 Tesla magnetic resonance unit with digital subtraction angiography with the latest flat-panel technology and 3D reconstruction in the evaluation of embolized cerebral aneurysms. INTRODUCTION: Many embolized aneurysms are subject to a recurrence of intra-aneurismal filling. Traditionally, imaging surveillance of coiled aneurysms has consisted of repeated digital subtraction angiography. However, this method has a small but significant risk of neurological complications, and many authors have advocated the use of noninvasive imaging methods for the surveillance of embolized aneurysms. METHODS: Forty-three aneurysms in 30 patients were studied consecutively between November 2009 and May 2010. Two interventional neuroradiologists rated the time-of-flight-magnetic resonance angiography, the contrast-enhanced-magnetic resonance angiography, and finally the digital subtraction angiography, first independently and then in consensus. The status of aneurysm occlusion was assessed according to the Raymond scale, which indicates the level of recanalization according to degrees: Class 1: excluded aneurysm; Class 2: persistence of a residual neck; Class 3: persistence of a residual aneurysm. The agreement among the analyses was assessed by applying the Kappa statistic. RESULTS: Inter-observer agreement was excellent for both methods (K = 0.93; 95 % CI: 0.84-1. Inter-technical agreement was almost perfect between time-of-flight-magnetic resonance angiography and digital subtraction angiography (K = 0.98; 95 % CI: 0.93-1 and between time-of-flight-magnetic resonance angiography and contrast-enhanced-magnetic resonance angiography (K = 0.98; 95% CI: 0.93-1. Disagreement occurred in only one case (2.3%, which was classified as Class I by time-of-flight-magnetic resonance angiography and Class II by digital subtraction angiography. The agreement between

  18. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot ... I’d like to talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA ...

  19. New method of digital angiography

    International Nuclear Information System (INIS)

    Hashiya, Junichi; Korenaga, Takeo; Sakurai, Kenji; Sakai, Fumikazu; Kato, Hisatoyo; Takano, Masao.

    1982-01-01

    New experience of digital angiography using Fuji Intelligent Diagnostic X-ray System was reported. The system utilizes newly developed high sensitivity imaging plate in conjunction with computerized image processor instead of image intensifier-TV series, thus drastically improving image quality. Initial clinical trial was made in 46 cases including intravenous digital subtraction angiography and transcatheter digital arteriography. The advantages of this method were summerized as: 1. better resolution, 2. wider field size, 3. more sophisticated image manipulation program. (author)

  20. Magnetic resonance angiography (MRA) of the circle of Willis: a prospective comparison with conventional angiography in 54 subjects

    International Nuclear Information System (INIS)

    Patrux, B.; Laissy, J.P.; Jouini, S.; Kawiecki, W.; Coty, P.; Thiebot, J.

    1994-01-01

    We prospectively correlated the findings of magnetic resonance angiography (MRA) with those of transfemoral four-vessel angiography in 54 patients to investigate the direction of flow within the circle of Willis. Our primary goal was to assess the direction of flow using the size of the vessel and signal intensity, without saturation techniques. Analysis of the circle of Willis, especially the communicating arteries, was performed double-blind by two groups of two radiologists. Three types of arteries were identified: high flow or cross-cerebral circulation, patent and nonvisualised arteries. Cerebral angiography was the standard for comparison between the two methods. MRA did not reveal any arteries invisible on angiography, thus providing a specificity of 100%. The sensitivity of MRA was 89.2% for the anterior and 81.3% for the posterior communicating arteries, and 100% for the anterior, middle and posterior cerebral arteries. MRA was shown to be a useful technique for the assessment of patency of the circle of Willis. (orig.)

  1. Magnetic resonance angiography (MRA) of the circle of Willis: a prospective comparison with conventional angiography in 54 subjects

    Energy Technology Data Exchange (ETDEWEB)

    Patrux, B. (Neuroradiology, CHU Charles Nicolle, Rouen (France)); Laissy, J.P. (Neuroradiology, CHU Charles Nicolle, Rouen (France) Dept. of Radiology, CHU Bichat, Paris (France)); Jouini, S. (Neuroradiology, CHU Charles Nicolle, Rouen (France)); Kawiecki, W. (Siemens Medical Systems, Saint-Denis (France)); Coty, P. (Neuroradiology, CHU Charles Nicolle, Rouen (France)); Thiebot, J. (Neuroradiology, CHU Charles Nicolle, Rouen (France))

    1994-04-01

    We prospectively correlated the findings of magnetic resonance angiography (MRA) with those of transfemoral four-vessel angiography in 54 patients to investigate the direction of flow within the circle of Willis. Our primary goal was to assess the direction of flow using the size of the vessel and signal intensity, without saturation techniques. Analysis of the circle of Willis, especially the communicating arteries, was performed double-blind by two groups of two radiologists. Three types of arteries were identified: high flow or cross-cerebral circulation, patent and nonvisualised arteries. Cerebral angiography was the standard for comparison between the two methods. MRA did not reveal any arteries invisible on angiography, thus providing a specificity of 100%. The sensitivity of MRA was 89.2% for the anterior and 81.3% for the posterior communicating arteries, and 100% for the anterior, middle and posterior cerebral arteries. MRA was shown to be a useful technique for the assessment of patency of the circle of Willis. (orig.)

  2. Preoperative MR angiography evaluation of transjugular intrahepatic portosystemic shunt

    International Nuclear Information System (INIS)

    Guo Li; Yang Dakuan; Yuan Shuguang; Yan Dong; Wang Jiaping; Li Yingchun

    2010-01-01

    Objective: To discuss the application of MR angiography (MRA) in deciding the puncture points of transjugular intrahepatic portosystemic shunt (TIPS). Methods: Preoperative MRA was performed in 59 patients with portal hypertension (study group) in order to search for the causes of portal hypertension, to observe the patterns and route of the hepatic and portal veins and to measure the vascular diameter at the scheduled puncture site. MRA was also performed in 50 healthy subjects, which was served as the control group. The results were compared between two groups. Results: The diseases in the study group included simple cirrhosis (n=49), cirrhosis accompanied with hepatocellular carcinoma (n=4), pure portal vein thrombosis (n=3), splenic vein stenosis (n=1) and Budd-Chiari syndrome (n=2). In study group the type I, II and III of the hepatic vein classification were seen in 14, 39 and 12 cases respectively,while in control group in 12, 34 and 14 cases respectively. In study group, the right, middle and left hepatic vein which had the diameter larger enough for puncturing existed in 52, 40 and 28 cases respectively, while in control group in 46, 34 and 23 cases respectively. The safe point for puncture via the right and the left branch of the portal vein was located beyond the distance of (16.2 ± 3.1) mm and (14.2 ± 3.8) mm respectively. Conclusion: MRA is a valuable non-invasive examination, which is of great value in determining the causes of portal hypertension and in planning the puncturing sites before performing TIPS. (authors)

  3. Treatment of arteriovenous malformations with stereotactic radiosurgery employing both magnetic resonance angiography and standard angiography as a database

    International Nuclear Information System (INIS)

    Petereit, D.; Mehta, M.; Turski, P.; Levin, A.; Strother, C.; Mistretta, C.; Mackie, R.; Gehring, M.; Kubsad, S.; Kinsella, T.

    1993-01-01

    Twenty-one arteriovenous malformations were prospectively evaluated using magnetic resonance angiography, compare it to stereotactic angiography, employ magnetic resonance angiography in follow-up, and semiquanitfy flow. A correlative evaluation between flow and response to stereotactic radiosurgery was carried out. Phase contrast angiograms were obtained at flow velocities of 400, 200, 100, 60 and 20 cm/sec. The fractionated velocities provided images that selectively demonstrated the arterial and venous components of the arteriovenous malformations. Qualitative assessment of the velocity within the arteriovenous malformations and the presence of fistulae were also determined by multiple velocity images. In addition, 3-dimensional time-of-flight magnetic resonance angiograms were obtained to define the exact size and shape of the nidus. This technique also permitted evaluation of the nidus and feeding arteries for the the presence of low flow aneurysms. Correlation between the two imaging modalities was carried out by subjective and semiquantitative estimation of flow velocity and estimation of nidus size. The following velocity parameters were employed: fast, intermediate, slow, and none. Early analysis suggests that slower flowing arteriovenous malformations may obliterate faster after stereotactic radiosurgery an flow parameters should be employed to predict response. In conclusion, magnetic resonance angiography permits semiquantitative flow velocity assessment and may therefore be superior to stereotactic angiography. An additional advantage of magnetic resonance angiography is the generation of serial transverse images which can replace the conventional CT scan employed for stereotactic radiosurgery treatment planning. A single diagnostic test may therefore be used for diagnosis, radiosurgical treatment planning, follow-up, and treatment selection by identifying patients likely to respond early to radiosurgical management

  4. Gadofosveset-enhanced MR angiography of the pedal arteries in patients with diabetes mellitus and comparison with selective intraarterial DSA

    International Nuclear Information System (INIS)

    Roehrl, Boris; Kunz, Rainer Peter; Oberholzer, Katja; Pitton, Michael Bernhard; Dueber, Christoph; Kreitner, Karl-Friedrich; Neufang, Achim

    2009-01-01

    To compare gadofosveset-enhanced magnetic resonance angiography (MRA) of the pedal vasculature with selective intraarterial DSA. Eighteen patients with PAOD and type II diabetes were prospectively examined at 1.5 T. For contrast enhancement, 0.03 mmol/kg body weight gadofosveset was used. MR imaging consisted of dynamic and of high-resolution steady-state imaging. Selective digital subtraction angiography (DSA) was performed within 5 days and served as standard of reference. Image analysis was done by two observers. There were no differences between MRA and DSA regarding overall image quality. First-pass MRA detected significantly more patent vessel segments than did DSA (P < 0.001, kappa = 0.46). Interobserver agreement of MRA was very good with respect to the detection of patent vessel segments and the assessment of hemodynamically relevant stenoses (kappa = 0.97 and 0.89, respectively). Steady-state imaging depicted significantly more patent metatarsal arteries than did dynamic imaging, and delineated inflammatory complications including osteomyelitis, soft-tissue abscesses, and fistulas related to the diabetic foot. Gadofosveset-enhanced MRA of the pedal vasculature proved to be superior to DSA. It offered a long imaging time window, and allowed for better depiction of the pedal outflow. Steady-state imaging delineated inflammatory complications associated with the diabetic foot. (orig.)

  5. Gadofosveset-enhanced MR angiography of the pedal arteries in patients with diabetes mellitus and comparison with selective intraarterial DSA

    Energy Technology Data Exchange (ETDEWEB)

    Roehrl, Boris; Kunz, Rainer Peter; Oberholzer, Katja; Pitton, Michael Bernhard; Dueber, Christoph; Kreitner, Karl-Friedrich [Johannes Gutenberg University Mainz, Department of Diagnostic and Interventional Radiology, Mainz (Germany); Neufang, Achim [Johannes Gutenberg University Mainz, Department of Cardiothoracic and Vascular Surgery, Mainz (Germany)

    2009-12-15

    To compare gadofosveset-enhanced magnetic resonance angiography (MRA) of the pedal vasculature with selective intraarterial DSA. Eighteen patients with PAOD and type II diabetes were prospectively examined at 1.5 T. For contrast enhancement, 0.03 mmol/kg body weight gadofosveset was used. MR imaging consisted of dynamic and of high-resolution steady-state imaging. Selective digital subtraction angiography (DSA) was performed within 5 days and served as standard of reference. Image analysis was done by two observers. There were no differences between MRA and DSA regarding overall image quality. First-pass MRA detected significantly more patent vessel segments than did DSA (P < 0.001, kappa = 0.46). Interobserver agreement of MRA was very good with respect to the detection of patent vessel segments and the assessment of hemodynamically relevant stenoses (kappa = 0.97 and 0.89, respectively). Steady-state imaging depicted significantly more patent metatarsal arteries than did dynamic imaging, and delineated inflammatory complications including osteomyelitis, soft-tissue abscesses, and fistulas related to the diabetic foot. Gadofosveset-enhanced MRA of the pedal vasculature proved to be superior to DSA. It offered a long imaging time window, and allowed for better depiction of the pedal outflow. Steady-state imaging delineated inflammatory complications associated with the diabetic foot. (orig.)

  6. Clinical experience of magnetic resonance angiography in hand surgery

    International Nuclear Information System (INIS)

    Kawabata, Hidehiko; Yasui, Natsuo; Kitano, Motohiro; Sai, Eikoh

    1996-01-01

    Magnetic resonance angiography was performed in fourteen patients with congenital hand abnormalities. A two-dimentional time-of-flight imaging clearly demonstrated presence or absence of the radial, ulnar, and anterior interosseous arteires at forearm. However, smaller arteries such as digital arteries were depressed sometimes. This fact makes clinical application of the method somewhat limited. At present. appropriate applications in orthopaedic fields are evaluation of run-off of the major vessels after trauma or atherosclerotic diseases, venous vascular problems such as thrombophlebitis and aneurysm, and preoperative and post operative evaluation in microsurgery. If more detailed information is required, for example, in differential diagnosis of tumors conventional angiography or digital subtraction angiography is recommended. Because magnetic resonance angiography is non-invasive and does not need anesthesia, it is suitable especially for children. No requirement of contrast medium makes it easy to apply angiography to high risk patients and allergic patients to iodine. Technical advancement in near future will rise up magnetic resonance angiography to a standard evaluation method for vascular problems in orthopaedic fields very soon. (author)

  7. Digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Ludwig, J.W.; Eikelboom, B.C.; Van Schaik, C.C.; Taams, A.J.; Teeuwen, C.

    1985-01-01

    Besides the non-invasive techniques, angiography remains essential. The disadvantages of angiography are the complexity of the procedure and the possibility of complications. Digital subtraction angiography (DSA) is a considerable improvement in the examination of vessels. In DSA, subtraction combined with enhancement of the signals allows the use of intravenous injection to obtain good images of the arteries. However, when the contrast material is supplied intravenously, a rather large amount of contrast material is necessary to obtain images of good quality. Quantities of 30-40 cc of contrast material are required. The advantage of the intravenous injection of contrast material rather than the use of a catheter to deliver the contrast material in loco is that it is almost non-invasive thus circumventing the complications caused by catheter manipulation in the arterial system. This makes it possible to apply this method on an out-patient basis. DSA can also be applied with intra-arterial selective injection of the contrast material. In this case, the strong enhancement with DSA allows the use of a small quantity of contrast material while still obtaining images of the vessels with good contrast definition

  8. Uterine artery embolization angiography and fertility related aspects

    Directory of Open Access Journals (Sweden)

    Irina A. Horhoianu

    2016-05-01

    Full Text Available Purpose. Uterine artery embolization is a minimally invasive technique. It applies the principle of targeted anatomical structure devascularisation with utility in fibroid conservative therapy, including for future fertility preserving status. The objective of our paper represents a description and evaluation of angiography utility as a predictive method for fertility maintenance. Material and Methods. The angiography and ultrasound aspects obtained from a prospective study in which selected patients have undergone uterine artery embolization for fertility preservation are detailed. Results. The following angiography aspects have been detected: left- right shunt and utero-ovarian collaterals; these have been compared with the ultrasound aspects related to the fibroid evolution form a volumetric and Doppler ultrasound point of view. The angiographical description predicts the impact on post embolization fibroid evolution and upon fertility. An analysis is made in order to assess the way in which angiography can contribute to fertility alteration. Conclusions. The angiography aspects during embolization and the following ultrasound aspects can represent predictive factors as to fertility evolution after uterine artery embolization.

  9. Selective angiography in fifty patients with primary hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Shou-Zhong, Wang; Xing-Rong, Chen; Gong-Xian, Wang

    1983-06-01

    Selective angiography is of great importance in the diagnosis of primary hepatocellular carcinoma. It offers information on the findings, multicentricity, localisation, extension, and type of growth. This paper discusses angiography from the methodical point of view, the findings to be obtained, the types of hepatocellular carcinoma, and the diagnostic efficiency of selective angiography in the evaluation of this type of tumour.

  10. Digital angiography and surgery in the same room

    International Nuclear Information System (INIS)

    Goldman, M.L.; Hack, S.N.; Sarrafizadeh, M.S.; Marar, H.G.; Behar, D.J.; Chigurupati, R.C.; Klein, S.I.; Widlus, D.M.; Fortune, J.B.

    1986-01-01

    Albany Medical Center and private industries (XRE and United X-ray corporations) have collaborated to develop a room within the operating suite that allows high-speed and high-resolution digital angiography and surgery to be performed simultaneously. Patients who have sustained massive trauma can be transferred directly from the ambulance to this new facility. While the patient is undergoing exploratory laparotomy, other vital areas of the body can be evaluated by angiography. This combined approach of surgery and angiography has also led to improved management of patients with massive or occult intestinal hemorrhage and patients with peripheral vascular disease. Other patients undergoing difficult emergency or elective surgery, as in the biliary tract, can now have available the benefits of an operating room facility that also allows high-resolution fluoroscopy and complete angiography to be undertaken

  11. A comparison of patient dose levels between 3/4 vessel conventional angiography and computed tomography angiography during examinations to investigate subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Spanton, David; Strudwick, Ruth M.

    2007-01-01

    The aim of this study was to investigate and compare the levels of ionising radiation dose received by patients whilst undergoing radiological examination for Subarachnoid haemorrhage by conventional angiography (single and bi plane) and computed tomography angiography. The results obtained from previous examinations have been compared to consider which method of investigation delivers the lowest ionising radiation dose to the patient. Consideration was also given to comparing single plane angiography to bi plane angiography as empirical evidence suggested that radiologists received no formal training and only a small amount of informal training on newly installed equipment at the hospital in which the research was carried out. Would this lead to patients being inadvertently exposed to increased radiation as radiologists familiarised themselves with the equipment? The dose received by 30 patients examined for SAH by each modality was converted to effective dose (mSv) for comparison. These results were then further compared by removing the lowest and highest recorded doses to eliminate any bias that may have been caused by skewed data. The results showed that CTA consistently delivered a lower dose to patients than single or bi plane angiography and that bi plane delivered a lower mean average dose than single plane angiography, with or without any skewed data

  12. Fluorescence angiography in retinal tumours

    Energy Technology Data Exchange (ETDEWEB)

    Fuhrmann, M [Staedtisches Klinikum Berlin-Buch (German Democratic Republic)

    1980-01-01

    On the basis of the available photographic material the results of fluorescein angiography are reported in 4 cases of retinoblastoma and 3 cases of Bourneville's disease. The clinical diagnosis of retinoblastoma was confirmed histologically in all cases since the first eye had been removed for the same reason previously. One child had not yet been treated, and in 3 cases radioactive isotopes were used in the treatment. In the group of phacomatosis the patients had only periodical outpatient examinations. The importance of this angiography in the diagnosis and follow-up of these diseases is stressed.

  13. Transient Global Amnesia following Neural and Cardiac Angiography May Be Related to Ischemia

    Directory of Open Access Journals (Sweden)

    Hongzhou Duan

    2016-01-01

    Full Text Available Introduction. Transient global amnesia (TGA following angiography is rare, and the pathogenesis has not been illustrated clearly till now. The aim of this research is to explore the pathogenesis of TGA following angiography by analyzing our data and reviewing the literature. Methods. We retrospectively studied 20836 cases with angiography in our hospital between 2007 and 2015 and found 9 cases with TGA following angiography. The data of these 9 cases were analyzed. Results. We found all 9 cases with TGA following neural angiography (5 in 4360 or cardiac angiography (4 in 8817 and no case with TGA following peripheral angiography (0 in 7659. Statistical difference was found when comparing the neural and cardiac angiography group with peripheral group (p=0.022. Two cases with TGA were confirmed with small acute infarctions in hippocampus after angiography. This might be related to the microemboli which were rushed into vertebral artery following blood flow during neural angiography or cardiac angiography. There was no statistical difference when comparing the different approaches for angiography (p=0.82 and different contrast agents (p=0.619. Conclusion. Based on the positive findings of imaging study and our analysis, we speculate that ischemia in the medial temporal lobe with the involvement of the hippocampus might be an important reason of TGA following angiography.

  14. Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism : a prospective study

    NARCIS (Netherlands)

    Oudkerk, M; van Beek, EJR; Wielopolski, P; van Ooijen, PMA; Brouwers-Kuyper, EMJ; Bongaerts, AHH; Berghout, A

    2002-01-01

    Background Diagnostic strategies for pulmonary embolism are complex and consist of non-invasive diagnostic tests done to avoid conventional pulmonary angiography as much as possible. We aimed to assess the diagnostic accuracy of magnetic resonance angiography (MRA) for the diagnosis of pulmonary

  15. Variation in form on the circle of Willis as studied by 3D-TOF MR angiography

    International Nuclear Information System (INIS)

    Hoshino, Haruhiko; Takagi, Makoto; Inafuku, Tetsuya; Adachi, Tomohide; Segawa, Hiroshi

    1996-01-01

    The circles of Willis in 2011 patients were examined by 3-dimensional time-of-flight MR angiography in order to evaluate the variations. The A1 segment of the anterior cerebral artery was not found in 4.8% on the right side and in 3.4% on the left side. In the older patients, MRA failed to demonstrate either the right or left A1 segment. A fetal configuration, whereby P1 segments had a smaller diameter than the posterior communicating artery and the posterior cerebral artery derived predominantly from the carotid artery, occurred in 19.8% on the right side and in 16.7% on the left side. MRA did not reveal the posterior communicating artery to be more common in the elderly. The circulatory states in the circle of Willis may alter with aging. (author)

  16. The comparative study on diagnostic validity of cerebral aneurysm by computed tomography angiography versus digital subtraction angiography after subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Masih Saboori

    2011-01-01

    Full Text Available Background: In order to declare the preoperative diagnostic value of brain aneurysms, two radiological modalities, computed tomographic angiography and digital subtraction angiography were compared. Methods: In this descriptive analytic study, diagnostic value of computed tomographic angiography (CTA was com-pared with digital subtraction angiography (DSA. Sensitivity, specificity, positive and negative predictive values were calculated and compared between the two modalities. All data were analyzed with SPSS software, version 16. Results: Mean age of patients was 49.5 ± 9.13 years. 57.9 % of subjects were female. CTA showed 89% sensitivity and 100% specificity whereas DSA demonstrated 74% sensitivity and 100% specificity. Positive predictive value of both methods was 100%, but negative predictive value of CTA and DSA was 85% and 69%, respectively. Conclusions: Based on our data, CTA is a valuable diagnostic modality for detection of brain aneurysm and su-barachnoid hemorrhage.

  17. Differential diagnosis of benign and malignant intraductal papillary mucinous tumors of the pancreas: MR cholangiopancreatography and MR angiography

    International Nuclear Information System (INIS)

    Choi, Byung Se; Kim, Tae Kyoung; Kim, Ah Young; Kim, Kyoung Won; Park, Sung Won; Kim, Pyo Nyun; Ha, Kyun Kwon; Lee, Moon Gyu; Kim, Song Cheol

    2003-01-01

    To compare the usefulness of magnetic resonance cholangiopancreatography (MRCP) and MR angiography (MRA) in differentiating malignant from benign intraductal papillary mucinous tumors of the pancreas (IPMTs), and to determine the findings which suggest malignancy. During a 6-year period, 46 patients with IPMT underwent MRCP. Morphologically, tumor type was classified as main duct, branch duct, or combined. The diameter of the main pancreatic duct (MPD), the extent of the dilated MPD, and the location and size of the cystic lesion, septum, and communicating channel were assessed. For all types of IPMTs, enhanced mural nodules and portal vein narrowing were evaluated at MRA. Combined-type IPMTs were more frequently malignant (78%) than benign (42%) (p<0.05). Compared with benign lesions, malignant lesions were larger, and the caliber of the communicating channel was also larger (p < 0.05). Their dilated MPD was more extensive and of greater diameter (p<0.05), and the presence of mural nodules was more frequent (p<0.001). Combined MRCP and MRA might be useful for the differential diagnosis of malignant and benign IPMTs of the pancreas

  18. Dynamic 3D-MR-angiography for assessing rheumatoid disease of the hand—A feasibility study

    International Nuclear Information System (INIS)

    Notohamiprodjo, Mike; Glaser, Christian; Horng, Annie; Helck, Andreas; Bauner, Kerstin U.; Reiser, Maximilian F.; Hatz, Hans J.; Weckbach, Sabine

    2012-01-01

    Purpose: To investigate highly temporally resolved MR-angiography (MRA) with time-resolved imaging with stochastic trajectories (TWIST) of the hand as supplementary tool for dynamic assessment of synovitis and vascular pathologies in rheumatoid diseases. Material and methods: A coronal dynamic TWIST–MRA-sequence (0.7 mm × 0.7 mm × 1.4 mm, temporal resolution 2.5 s, time of acquisition 4 min) of the predominantly affected hand of 17 patients with suspected rheumatoid disease was acquired after contrast administration (Multihance, Bracco Imaging SpA) at 3 T (Magnetom VERIO, 8-channel-knee-coil, Siemens Healthcare). As standard of reference, contrast enhanced non fat-saturated coronal and fat-saturated axial T1-w sequences were acquired. These static sequences and the dynamic TWIST–MRA–maximum-intensity-projections (MIP) were separately assessed by two readers in consensus, recording the number of synovial lesions (wrist, intercarpal, metacarpophaleangal/proximal/distal interphalangeal joints), signs of tenosynovitis and vasculitis. Diagnostic confidence was rated (4-point-scale: 4 = excellent; 1 = non-diagnostic). Statistical significance was tested using the Wilcoxon-rank-sum-test. Results: An insignificantly lower number of synovial lesions (n = 72 vs. 89; p = 0.1) and only 3/9 cases with tenosynovitis were identified by the TWIST–MRA. For detected lesions, diagnostic confidence was comparable (MRA: 3.64; static T1-w post contrast: 3.47). In patients with high clinical activity dynamic MRA showed very early synovial enhancement. Only dynamic MRA detected 3 cases of vasculitis (subsequently confirmed with digital-subtraction-angiography). Conclusion: TWIST–MRA facilitates fast detection of synovitis. Although dynamic MRA of the hand is inferior to static contrast enhanced sequences in assessing the number of synovitic and tenosynovitic lesions, its high temporal resolution allows for fast visual grading of disease activity and assessment of vasculitis

  19. Abnormal pulmonary vein drainage in upper right lobe associated with double aortic arch : magnetic resonance angiography

    International Nuclear Information System (INIS)

    Busto, M.; Dolz, J.L.; Capdevilla, A.; Castanon, M.; Mulet, J.

    1997-01-01

    We present the magnetic resonance (MR) and magnetic resonance angiography (MRA) findings in a case of abnormal pulmonary vein drainage from upper right lobe to superior vena cava, associated with double aortic arch, in a six-month-old boy. (Author) 9 refs

  20. Development of serial magnification angiography and its clinical significance

    International Nuclear Information System (INIS)

    Sasaki, Tsuneo; Matsubara, Kazuhito; Ishiguchi, Tsuneo; Mashita, Shinichi; Kaii, Osamu

    1979-01-01

    In order to apply serial magnification angiography to clinical examinations so easily, a serial cardioangiography apparatus was equipped with a tube having 0.1 mm focal spot and with DRX-431HD diode. A CAT-FK Type catheter bed (Toshiba) was used as a roentgenographic table and a PUCK film changer was used. Thus, serial magnification angiography can be easily used to clinical examinations, and can be set in a usual x-ray photographic studio. Serial magnification angiography was used to examine the cerebral vessels in 6 patients, vessels of the pulmonary circulation in 1 patient, bronchial arteries in 6 patients, the celiac artery in 18 patients, the superior mesenteric artery in 2 patients, inferior mesenteric artery in 2 patients, the renal artery in 2 patients, and the adrenal vein in 7 patients. Owing to this angiography, minute changes in the vessel in the lesion can be observed and fine neovascularity can be detected. Thus, serial magnification angiography makes diagnoses of vascular disorders easier. (Ichikawa, K.)

  1. Angiography of the upper extremity

    International Nuclear Information System (INIS)

    Janevski, B.K.

    1982-01-01

    This thesis provides a description of the technical and medical aspects of arteriography of the upper extremity and an extensive analysis of the angiographic anatomy and pathology of 750 selective studies performed in more than 500 patients. A short historical review is provided of angiography as a whole and of arteriography of the hand in particular. The method of percutaneous transfemoral catheterization of the arteries of the upper extremity and particularly the arteries of the hand is considered, discussing the problems the angiographer encounters frequently, describing the angiographic complications which may occur and emphasizing the measures to keep them to a minimum. The use of vasodilators in hand angiography is discussed. A short description of the embryological patterns persisting in the arteries of the arm is included in order to understand the congenital variations of the arteries of the upper extremity. The angiographic patterns and clinical aspects of the most common pathological processes involving the arteries of the upper extremities are presented. Special attention is paid to the correlation between angiography and pathology. (Auth.)

  2. Simultaneous static and cine nonenhanced MR angiography using radial sampling and highly constrained back projection reconstruction.

    Science.gov (United States)

    Koktzoglou, Ioannis; Mistretta, Charles A; Giri, Shivraman; Dunkle, Eugene E; Amin, Parag; Edelman, Robert R

    2014-10-01

    To describe a pulse sequence for simultaneous static and cine nonenhanced magnetic resonance angiography (NEMRA) of the peripheral arteries. The peripheral arteries of 10 volunteers and 6 patients with peripheral arterial disease (PAD) were imaged with the proposed cine NEMRA sequence on a 1.5 Tesla (T) system. The impact of multi-shot imaging and highly constrained back projection (HYPR) reconstruction was examined. The propagation rate of signal along the length of the arterial tree in the cine nonenhanced MR angiograms was quantified. The cine NEMRA sequence simultaneously provided a static MR angiogram showing vascular anatomy as well as a cine display of arterial pulse wave propagation along the entire length of the peripheral arteries. Multi-shot cine NEMRA improved temporal resolution and reduced image artifacts. HYPR reconstruction improved image quality when temporal reconstruction footprints shorter than 100 ms were used (P cine NEMRA was slower in patients with PAD than in volunteers. Simultaneous static and cine NEMRA of the peripheral arteries is feasible. Multi-shot acquisition and HYPR reconstruction can be used to improve arterial conspicuity and temporal resolution. Copyright © 2013 Wiley Periodicals, Inc.

  3. Effective selection of hypertensive patients for angiography

    International Nuclear Information System (INIS)

    van der Voorde, F.; Derkx, F.H.M.; Bossuyt, P.M.M.; Segaar, R.W.; de Wind, A.; Pieterman, H.

    1989-01-01

    The authors prospectively observed 373 severe hypertensives with either diastolic blood pressure (BP) ≥ 105 and age ≤ 40, or BP with three drugs ≥ 105 (regardless of age). Excluded were patients who were older than 75 or who had creatinine >400. History, physical examination, and laboratory data were used to identify high-yield criteria for arteriography. All patients underwent angiography as the gold standard; angiography showed 127 unilateral renal artery stenoses, 73 bilateral renal artery stenoses, and 173 (nonstenosed) essential hypertensives. The authors constructed a logistic regression model of height, weight, age, smoking, and hypertension duration, which could be used to identify 90% of stenosed patients with 50% fewer angiographies in the essential hypertensives

  4. MR angiography and the preoperative evaluation of renal arteries

    International Nuclear Information System (INIS)

    Nakahara, Kimitoshi; Yokoyama, Hiroshi; Tsuji, Yuji

    2001-01-01

    To determine the accuracy of gadolinium-enhanced, three-dimensional, magnetic resonance angiography (3D-MRA) in the visualization of the arterial anatomy of the kidney, we compared preoperative 3D-MRA results with surgical findings in 37 patients who underwent renal surgery. 3D-MRA findings were confirmed surgically in 30 of these patients (81%). However, 4 of 7 accessory renal arteries were missed by this imaging technique. Furthermore, 3D-MRA failed to visualize renal arteries in all of the three atrophic kidneys. 3D-MRA is a safe and reliable procedure for the preoperative evaluation of renal arteries. However, the depiction of smaller renal arteries, such as accessory and atrophic arteries, is less accurate. (author)

  5. MR angiography and the preoperative evaluation of renal arteries

    Energy Technology Data Exchange (ETDEWEB)

    Nakahara, Kimitoshi; Yokoyama, Hiroshi; Tsuji, Yuji [Fukuoka Univ. (Japan). School of Medicine

    2001-04-01

    To determine the accuracy of gadolinium-enhanced, three-dimensional, magnetic resonance angiography (3D-MRA) in the visualization of the arterial anatomy of the kidney, we compared preoperative 3D-MRA results with surgical findings in 37 patients who underwent renal surgery. 3D-MRA findings were confirmed surgically in 30 of these patients (81%). However, 4 of 7 accessory renal arteries were missed by this imaging technique. Furthermore, 3D-MRA failed to visualize renal arteries in all of the three atrophic kidneys. 3D-MRA is a safe and reliable procedure for the preoperative evaluation of renal arteries. However, the depiction of smaller renal arteries, such as accessory and atrophic arteries, is less accurate. (author)

  6. Digital subtraction cerebral angiography by intraarterial injection: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Gould, R.; Norman, D.; Newton, T.H.; Lane, B.

    1983-01-01

    For 4 months, a prototype digital subtraction system was used to obtain images of the cerebral vasculature after intraarterial contrast injections. In 12 instances, the intraarterial injections were recorded with both a digital subtraction unit and conventional direct magnification film-screen system. The digital subtraction and conventional film subtraction images were compared and graded for quality and information content by three skilled observers. In addition, quantitative measurements of contrast-detail performance and spatial resolution were obtained on both the digital system and the screen-film imaging chain. In a clinical setting, both the digital subtraction and conventional film-screen systems provided similar quality images and angiographic information. Contrast-detail curves demonstrated that digital subtraction angiography outperformed conventional film technique for low-contrast objects. Digital subtraction angiography also reduced the time required to obtain the angiogram, markedly reduced film cost, and lowered the contrast agent burden

  7. Fluorescence angiography in retinal tumours

    International Nuclear Information System (INIS)

    Fuhrmann, M.

    1980-01-01

    On the basis of the available photographic material the results of fluorescein angiography are reported in 4 cases of retinoblastoma and 3 cases of Bourneville's disease. The clinical diagnosis of retinoblastoma was confirmed histologically in all cases since the first eye had been removed for the same reason previously. One child had not yet been treated, and in 3 cases radioactive isotopes were used in the treatment. In the group of phacomatosis the patients had only periodical outpatient examinations. The importance of this angiography in the diagnosis and follow-up of these diseases is stressed. (author)

  8. Optimization of Ecg Gating in Quantitative Femoral Angiography

    International Nuclear Information System (INIS)

    Nilsson, S.; Berglund, I.; Erikson, U.; Johansson, J.; Walldius, G.

    2003-01-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase

  9. Optimization of Ecg Gating in Quantitative Femoral Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, S.; Berglund, I.; Erikson, U. [Univ. Hospital, Uppsala (Sweden). Dept. of Oncology, Radiology and Clinical Immunology; Johansson, J.; Walldius, G. [Karolinska Hospital, Stockholm (Sweden). King Gustav V Research Inst.

    2003-09-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase.

  10. Echo-planar MR imaging of dissolved hyperpolarized 129Xe. Potential for M angiography

    International Nuclear Information System (INIS)

    Maansson, S.

    2002-01-01

    Purpose: The feasibility of hyperpolarized 129 Xe for fast MR angiography (MRA) was evaluated using the echo-planar imaging (EPI) technique. Material and Methods: Hyperpolarized Xe gas was dissolved in ethanol; a carrier agent with high solubility for Xe (Ostwald solubility coefficient 2.5) and long relaxation times. The dissolved Xe was injected as a bolus into a flow phantom where the mean flow velocity was 15 cm/s. Ultrafast EPI images with 44 ms scan time were acquired of the flowing bolus and the signal-to-noise ratios (SNR) were measured. Results: The relaxation times of hyperpolarized Xe in ethanol were measured to T1=160±11 s and T2 ≅ 20 s. The resulting images of the flowing liquid were of reasonable quality and had an SNR of about 70. Conclusion: Based on the SNR of the obtained Xe EPI images; it was estimated that rapid in vivo MRA with 129 Xe may be feasible; provided that an efficient; biologically acceptable carrier for Xe can be found and polarization levels of more than 25% can be achieved in isotopically enriched 129 Xe

  11. Catheter versus non-catheter angiography in isolated third nerve palsy

    International Nuclear Information System (INIS)

    Lee, A.G.

    2007-01-01

    To discuss the controversies surrounding the indications for catheter angiography versus non-catheter and less invasive angiography techniques (e.g. magnetic resonance angiography (MRA) and computerized tomography angiography (CTA)) in the evaluation of patients with a third nerve palsy. Clinical opinion-perspective and literature review. The patient with an isolated third nerve palsy might have a vasculopathic (and typically benign, self limited course) etiology or a life threatening intracranial posterior communicating artery aneurysm. Although it is clear that non-isolated third nerve palsies require imaging directed at the topographical localization of the clinical findings, the evaluation of the neurologically isolated third nerve palsy remains controversial. The completeness of the external (i.e. somatic) motor dysfunction and the presence or absence of internal (i.e. pupillary) dysfunction are generally used to guide the choice of initial neuroimaging. Advances in MRA and CTA technology have reduced but not eliminated our dependence upon catheter angiography in this setting. A properly performed and interpreted MRA or CTA probably will be able to detect greater than 95 % of aneurysms producing a third nerve palsy. The issues surrounding the use of catheter angiography in third nerve palsy are reviewed. If the clinician is highly confident in the capability, availability, and reliability of the neuroradiologist and of their institutional experience and quality of less invasive non-catheter MRA and CTA and if the risk of aneurysm is low or if the risk of angiography is high (e.g. elderly, renal failure, iodinated contrast allergy, risk of stroke) then MRI and MRA (or CTA) may be a reasonable alternative to catheter angiography. Patients with a moderate or uncertain risk of aneurysm and a lower risk for catheter angiography or if there is a low confidence in the quality or the interpretation of the institutional MRA (or CTA) may still require catheter

  12. Intra-arterial digital subtraction angiography (IA-DSA) with carbon dioxide

    International Nuclear Information System (INIS)

    Takeda, Toshiaki; Ido, Kunio; Yuasa, Yuji

    1988-01-01

    Intra-Arterial Digital Subtraction Angiography (IA-DSA) with Carbon Dioxide (CO 2 ) was performed on 41 patients mainly with liver or renal diseases, and its angiographic manifestation was compared with that of conventional angiography. Although the image quality of the arterial or capillary phase was inferior to that of conventional angiography with iodinated contrast media, the detectablity of arterio-venous shunting was excellent. In fact, DSA with CO 2 revealed the presence of A-V (A-P) shunt in 26 patients (26/41:63.4 % HCC, 13/15:86.7% metastatic liver tumor, 2/3:66.7 % RCC, 1/5:20 %). On the other hand, conventional angiography was able to show in only 5 cases. DSA with CO 2 will become an effective method for detecting minute arterio-venous shunting which can not be demonstrated with conventional angiography. (author)

  13. Comparison between angiography and CT scan in the urologic field

    Energy Technology Data Exchange (ETDEWEB)

    Fujioka, Toshio; Takao, Masaya; Odajima, Kunio; Nakamura, Hiroshi

    1988-02-01

    Seventy-five consecutive patients with urological diseases were examined preoperatively by means of computerized tomography and renal angiography. Classification of the diseases were 53 renal diseases which included renal cell carcinoma, sarcoma, cyst, renal bleeding, arteriovenous fistula, trauma, hydronephrosis and tuberculosis, 11 vesical diseases which included bladder tumor and endometriosis, 9 adrenal diseases which included primary aldosteronism, Cushing syndrome, pheochromocytoma, and metastatic tumor, and 1 case of intra-abdominal testes. For renal diseases, both angiography and CT were useful imaging tools. For vesical diseases, CT was a more useful imaging method but, for adrenal diseases, angiography was superior to CT. CT offers certain advantages over conventional techniques but, in the near future, it may be replaced by MRI. On the contrary, angiography will remain popular for a long time, because angiography is the only way to show which vessels feed organs.

  14. MRI and MR angiography of vertebral artery dissection

    International Nuclear Information System (INIS)

    Mascalchi, M.; Bianchi, M.C.; Mangiafico, S.; Ferrito, G.; Puglioli, M.; Marin, E.; Mugnai, S.; Canapicchi, R.; Quilici, N.; Inzitari, D.

    1997-01-01

    A review of 4,500 angiograms yielded 11 patients with dissection of the vertebral arteries who had MRI and (in 4 patients) MR angiography (MRA) in the acute phase of stroke. One patient with incidental discovery at arteriography of asymptomatic vertebral artery dissection and two patients with acute strokes with MRI and MRA findings consistent with vertebral artery dissection were included. Dissection occurred after neck trauma or chiropractic manipulation in 4 patients and was spontaneous in 10. Dissection involved the extracranial vertebral artery in 9 patients, the extra-intracranial junction in 1, and the intracranial artery in 4. MRI demonstrated infarcts in the brain stem, cerebellum, thalamus or temporo-occipital regions in 7 patients with extra- or extra-intracranial dissections and a solitary lateral medullary infarct in 4 patients (3 with intracranial and 1 with extra-intracranial dissection). In 2 patients no brain abnormality related to vertebral artery dissection was found and in one MRI did not show subarachnoid haemorrhage revealed by CT. Intramural dissecting haematoma appeared as crescentic or rounded high signal on T1-weighted images in 10 patients examined 3-20 days after the onset of symptoms. The abnormal vessel stood out in the low signal cerebrospinal fluid in intracranial dissections, whereas it was more difficult to detect in extracranial dissections because of the intermediate-to-high signal of the normal perivascular structures and slow flow proximal and distal to the dissection. In two patients examined within 36 h of the onset, mural thickening was of intermediate signal intensity on T1-weighted images and high signal on spin-density and T2-weighted images. MRA showed abrupt stenosis in 2 patients and disappearance of flow signal at and distal to the dissection in 5. Follow-up arteriography, MRI or MRA showed findings consistent with occlusion of the dissected vessel in 6 of 8 patients. (orig.). With 7 figs., 3 tabs

  15. Spiral CT angiography of renal arteries: comparison with angiography

    International Nuclear Information System (INIS)

    Wittenberg, G.; Kenn, W.; Tschammler, A.; Sandstede, J.; Hahn, D.

    1999-01-01

    A prospective study was carried out to determine the accuracy of spiral CT angiography (CTA) in the detection of renal artery stenosis (RAS). Eighty-two patients with arterial hypertension underwent CTA and digital subtraction angiography (DSA) to exclude RAS. For CTA a contrast medium bolus of 100-150 ml (flow rate 3 ml/s) was injected. A 24 or 40 s CTA was started at the origin of the superior mesenteric artery after a delay time determined by test bolus injection (collimation = 2 mm, pitch = 1/1.5). For stenosis detection transverse images supported by maximum intensity projections (MIP) or multiplanar reconstruction projections were used. Of 197 renal arteries examined (including 33 accessory arteries), 34 RAS were visualized using DSA. With CTA, one hemodynamic RAS was missed and one additional hemodynamic RAS was found. Sensitivity/specificity was calculated to be 94 %/98 %. For hemodynamically relevant RAS (> 50 %) the sensitivity/specificity was 96 %/99 %. CTA additionally depicted five adrenal masses. The high accuracy rate of RAS detection thus allows the use of CTA as a screening method in patients with arterial hypertension to exclude a renovascular cause. (orig.)

  16. Angiography in tumors of cartilaginous genesis

    International Nuclear Information System (INIS)

    Korolev, V.I.

    1986-01-01

    Angiography was used for 122 patients with tumors and tumor-like processes of the cartilage. Angiography was carried out by the S. Seldinger method. Normal angioarchitecture was observed in 16 patients with benign tumors (20 patients), characters of malignant tumor are determined in 4 patients. Normal angioarchitecture is determined in 9.4% of patients with chondrosarcoma (102 patients). The examination carried out showed that angiographic symptotics in chondrosarcomas varied depending on the stage, localization and the degree of morphologic differentiation

  17. Venous digital subtraction angiography for diagnosis of renal artery stenosis in arterial hypertony

    International Nuclear Information System (INIS)

    Schoerner, W.; Kempter, H.; Banzer, D.; Aviles, C.; Weiss, T.; Felix, R.

    1984-01-01

    Venous digital subtraction angiography was performed in 248 patients for the diagnosis of renal arterial stenosis. In 88% of the investigations the stenosis could be found. Comparison of digital angiography and conventional angiography was made for 57 renal arteries (25 investigations). In 52 renal arteries we found the same results with both methods, in 5 renal arteries we found the same results with both methods, in 5 renal arteries the digital angiography showed false positive results. The spatial resolution of digital subtraction angiography is sufficient for the correct diagnosis of significant renal arterial stenosis. With regard to the lower invasion of digital subtraction angiography compared to conventional angiography the first method should be used for clarification of renal arterial hypertension. (orig.)

  18. Susceptibility-weighted angiography (SWAN) of cerebral veins and arteries compared to TOF-MRA

    International Nuclear Information System (INIS)

    Boeckh-Behrens, T.; Lutz, J.; Lummel, N.; Burke, M.; Wesemann, T.; Schöpf, V.; Brückmann, H.; Linn, J.

    2012-01-01

    Problem: High resolution, non-contrast imaging of both cerebral veins and arteries by use of gradient echo T2 star weighted angiography (SWAN) is a new method for susceptibility-weighted imaging with short acquisition times. We assessed the potential of this sequence for the depiction of both cerebral veins and arteries. Methods: 15 healthy volunteers were included in the study. MRI was performed on a 3 T MR scanner using the following sequences: (1) a 3D multi-echo gradient echo T2 star weighted angiography (SWAN), (2) an arterial 3D TOF MR angiography and (3) a venous 2D TOF. With regard to the SWAN sequence, both MinIP and MIP images were reconstructed and systematically compared to MIP reconstructions of the artTOF and the venTOF. To suggest possible clinical implications of our findings, we additionally included two illustrative cases. Results: With regard to the visualization of the cerebral veins, the MinIP reconstructions of the SWAN sequence were considerably superior compared to the venTOF. Concerning the depiction of the main segments of the big cerebral arteries the value of the MIP reconstructions of the SWAN was comparable to that of the artTOF with limitations in the homogenity and in the depiction of smaller arteries. Conclusions: SWAN allows for high-resolution visualization of both cerebral veins and arteries in one sequence without application of contrast agent and with significantly shortened scan time compared to the combined scan time of TOF-MRA and TOF-MRV. By use of either MinIP or MIP reconstructions, the arteries can be distinguished from the veins.

  19. Microsurgical management of cerebral aneurysms based in CT angiography with three-dimensional reconstruction (3D-CTA) and without preoperative cerebral angiography

    International Nuclear Information System (INIS)

    Gonzalez-Darder, J.M.; Pesudo-Martinez, J.V.; Feliu-Tatay, R.A.

    2001-01-01

    Objective. To study the possibilities of the microsurgical management of ruptured intracranial aneurysms with the sole preoperative information provided by computed tomography angiography with three-dimensional reconstruction (3D-CTA). Methods. Patients were studied with 3D-CTA after diagnosis of subarachnoid hemorrhage. If the study had an adequate quality and revealed an aneurysm congruent with the clinical findings or neurological examination and/or with the location of the bleeding on computed tomography (CT) scan an early microsurgical clipping of the lesion was done. When the quality of the 3D-CTA study was not adequate or the quality being adequate displayed no lesions or the findings were not accurate enough to warrant direct microsurgical treatment, the patient was studied with cerebral digital substraction (DS) angiography. A total of 44 consecutive patients harboring a total of 47 intracranial aneurysms diagnosed by 3D-CTA and without preoperative DS angiography were submitted to microsurgical clipping and included in the study. Results. The overall mortality was 15.9 % and the favorable results evaluated 6 months after discharge by means of the Glasgow outcome scale reached 70.4 %. All lesions were successfully clipped. Surgery was done a mean of 4.1 days after the admission bleeding. A total of four microlesions undiagnosed by 3D-CTA were found at surgery and clipped. Postoperative DS angiography and necropsy findings were also used as control of the 3D-CTA findings but no additional information was provided excepting the finding in DS angiography of an asymptomatic intracavemous aneurysm. Therefore the sensitivity of the 3D-CTA for diagnosis of symtomatic aneurysms was 100 % and the overall sensitivity 90.4 %. Conclusions. We have reached similar results in patients operated on with or without preoperative angiography. 3D-CTA provides very valuable anatomical information, which has an additional value in the microsurgical treatment of aneurysms of the

  20. Assessment of chronic thromboembolic pulmonary hypertension by three-dimensional contrast-enhanced MR angiography - comparison with selective intraarterial DSA

    International Nuclear Information System (INIS)

    Kreitner, K.F.; Ley, S.; Kauczor, H.U.; Kalden, P.; Pitton, M.B.; Thelen, M.; Mayer, E.; Laub, G.

    2000-01-01

    Purpose: This study compares contrast-enhanced 3D-MR angiography (MRA) of the pulmonary arteries with selective intraarterial DSA in patients with chronic thromboembolic pulmonary hypertension. Materials and methods: 20 patients preoperatively underwent a contrast-enhanced 3D-MRA of the pulmonary arteries at 1.5 T using the phased-array body coil. For MRA, we used a 3D-Flash-sequence after bolus timing. 2 radiologists analyzed the acquired image material in consensus with respect to the detection of central thromboembolic material and the visualization of the pulmonary arterial tree. Finally, the MR angiograms were compared with selective DSA images using surgical findings as the definitive standard. Results: MRA demonstrated central thromboembolic material, vessel cut-offs and abnormal proximal-to-distal tapering in all patients. Compared to DSA, MRA depicted the pulmonary vessels up to the segmental level in all cases, it was inferior to DSA in delineation of the subsegmental arteries (sensitivity 87%, specificity 100%). The central beginning of the thromboembolic occlusions seen at MRA corresponded to the beginning of the deobliteration procedure during pulmonary thromboendarterectomy in every case. (orig.) [de

  1. The value of MR angiography in predicting the risk of torsion of a pelvic spleen during pregnancy

    International Nuclear Information System (INIS)

    Karantanas, A.H.; Stagianis, K.D.

    2002-01-01

    A case of an enlarged pelvic spleen, studied with MRI and MR angiography (MRA), is presented in a 32-year-old female wishing to become pregnant. An ectopic located spleen may be complicated by an acute abdomen due to torsion of the splenic vascular pedicle, resulting in splenic infarction. Displacement of the spleen and splenic pedicle during pregnancy may further increase the risk of torsion. Urgent splenectomy during pregnancy is associated with a high fetal and maternal mortality and morbidity. On the other hand, elective splenectomy of a pelvic spleen before pregnancy can result in adhesion formation, compromising the patient's fertility. The abilities of MRI and MRA in predicting the risk of these life-threatening complications during pregnancy are discussed, in order to evaluate the benefit-risk ratio of surgical treatment by splenectomy of splenopexia. (orig.)

  2. The value of MR angiography in predicting the risk of torsion of a pelvic spleen during pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Karantanas, A.H. [Department of CT-MRI, Larissa General Hospital (Greece); Stagianis, K.D. [Department of Obstetrics and Gynecology, University Hospital, Larissa (Greece)

    2002-02-01

    A case of an enlarged pelvic spleen, studied with MRI and MR angiography (MRA), is presented in a 32-year-old female wishing to become pregnant. An ectopic located spleen may be complicated by an acute abdomen due to torsion of the splenic vascular pedicle, resulting in splenic infarction. Displacement of the spleen and splenic pedicle during pregnancy may further increase the risk of torsion. Urgent splenectomy during pregnancy is associated with a high fetal and maternal mortality and morbidity. On the other hand, elective splenectomy of a pelvic spleen before pregnancy can result in adhesion formation, compromising the patient's fertility. The abilities of MRI and MRA in predicting the risk of these life-threatening complications during pregnancy are discussed, in order to evaluate the benefit-risk ratio of surgical treatment by splenectomy of splenopexia. (orig.)

  3. Comparison between digital subtraction angiography and magnetic resonance angiography in investigation of nonlacunar ischemic stroke in young patients: preliminary results.

    Science.gov (United States)

    Conforto, Adriana Bastos; Fregni, Felipe; Puglia, Paulo; Leite, Claudia da Costa; Yamamoto, Fabio Iuji; Coracini, Karen F; Scaff, Milberto

    2006-06-01

    We preliminarily investigated the relevance of performing digital subtraction angiography (DSA) in addition to magnetic resonance angiography (MRA) in definition of ischemic stroke etiology in young patients. DSAs and MRAs from 17 young patients with nonlacunar ischemic stroke were blindly analyzed and their impact on stroke management was evaluated. Etiologies were the same considering results of either DSA or MRA in 12/17 cases. In 15/17 patients no changes would have been made in treatment, regardless of the modality of angiography considered. These preliminary results suggest that DSA may be redundant in two thirds of ischemic strokes in young patients. Further larger prospective studies are necessary to determine indications of DSA in this age group.

  4. Magnetic resonance angiography: Physical principles and clinical applications

    International Nuclear Information System (INIS)

    Hausmann, R.; Mueller, E.

    1992-01-01

    Within the last four years magnetic resonance angiography (MRA) developed very rapidly towards a well accepted screening technique for vascular examinations as a fast add-on to conventional MR. This review describes the basic physical principles as well as the different methods like time-of-flight and phase-sensitive MRA for visualization of blood vessels. Different applications of 3D, 2D sequential and 3D multivolume MRA are shown from various regions of the head and body. A short outlock to quantitative flow measurments is given in the last chapter including some interesting applications of these techniques which show the still expanding potential of magnetic resonance. (orig.) [de

  5. Multislice CT Angiography in Renal Artery Stent Evaluation: Prospective Comparison with Intra-Arterial Digital Subtraction Angiography

    International Nuclear Information System (INIS)

    Raza, Syed A.; Chughtai, Aamer R.; Wahba, Mona; Cowling, Mark G.; Taube, David; Wright, Andrew R.

    2004-01-01

    Purpose: To assess the role of multislice computed tomography angiography (MCTA) in the evaluation of renal artery stents, using intra-arterial digital subtraction angiography (DSA) as the gold standard. Methods: Twenty consecutive patients (15 men, 5 women) with 23 renal artery stents prospectively underwent both MCTA and DSA. Axial images, multiplanar reconstructions and maximum intensity projection images were used for diagnosis. The MCTA and DSA images were each interpreted without reference to the result of the other investigation. Results:The three cases of restenosis on DSA were detected correctly by MCTA; in 19 cases where MCTA showed a fully patent stent, the DSA was also negative. Sensitivity and negative predictive value (NPV) of MCTA were therefore 100%. In four cases, MCTA showed apparently minimal disease which was not shown on DSA. These cases are taken as false positive giving a specificity of 80% and a positive predictive value of 43%. Conclusion: The high sensitivity and NPV suggest MCTA may be useful as a noninvasive screen for renal artery stentrestenosis. MCTA detected mild disease in a few patients which was not confirmed on angiography

  6. Synchrotron-based intravenous cerebral angiography in a small animal model

    International Nuclear Information System (INIS)

    Kelly, Michael E; Schueltke, Elisabeth; Fiedler, Stephan; Nemoz, Christian; Guzman, Raphael; Corde, Stephanie; Esteve, Francois; LeDuc, Geraldine; Juurlink, Bernhard H J; Meguro, Kotoo

    2007-01-01

    K-edge digital subtraction angiography (KEDSA), a recently developed synchrotron-based technique, utilizes monochromatic radiation and allows acquisition of high-quality angiography images after intravenous administration of contrast agent. We tested KEDSA for its suitability for intravenous cerebral angiography in an animal model. Adult male New Zealand rabbits were subjected to either angiography with conventional x-ray equipment or synchrotron-based intravenous KEDSA, using an iodine-based contrast agent. Angiography with conventional x-ray equipment after intra-arterial administration of contrast agent demonstrated the major intracranial vessels but no smaller branches. KEDSA was able to visualize the major intracranial vessels as well as smaller branches in both radiography mode (planar images) and tomography mode. Visualization was achieved with as little as 0.5 ml kg -1 of iodinated contrast material. We were able to obtain excellent visualization of the cerebral vasculature in an animal model using intravenous injection of contrast material, using synchrotron-based KEDSA

  7. Postmortem CT Angiography Compared with Autopsy: A Forensic Multicenter Study.

    Science.gov (United States)

    Grabherr, Silke; Heinemann, Axel; Vogel, Hermann; Rutty, Guy; Morgan, Bruno; Woźniak, Krzysztof; Dedouit, Fabrice; Fischer, Florian; Lochner, Stefanie; Wittig, Holger; Guglielmi, Giuseppe; Eplinius, Franziska; Michaud, Katarzyna; Palmiere, Cristian; Chevallier, Christine; Mangin, Patrice; Grimm, Jochen M

    2018-05-01

    Purpose To determine if postmortem computed tomography (CT) and postmortem CT angiography help to detect more lesions than autopsy in postmortem examinations, to evaluate the strengths and weaknesses of each method, and to define their indications. Materials and Methods Postmortem CT angiography was performed on 500 human corpses and followed by conventional autopsy. Nine centers were involved. All CT images were read by an experienced team including one forensic pathologist and one radiologist, blinded to the autopsy results. All findings were recorded for each method and categorized by anatomic structure (bone, organ parenchyma, soft tissue, and vascular) and relative importance in the forensic case (essential, useful, and unimportant). Results Among 18 654 findings, autopsies helped to identify 61.3% (11 433 of 18 654), postmortem CT helped to identify 76.0% (14 179 of 18 654), and postmortem CT angiography helped to identify 89.9% (16 780 of 18 654; P < .001). Postmortem CT angiography was superior to autopsy, especially at helping to identify essential skeletal lesions (96.1% [625 of 650] vs 65.4% [425 of 650], respectively; P < .001) and vascular lesions (93.5% [938 of 1003] vs 65.3% [655 of 1003], respectively; P < .001). Among the forensically essential findings, 23.4% (1029 of 4393) were not detected at autopsy, while only 9.7% (428 of 4393) were missed at postmortem CT angiography (P < .001). The best results were obtained when postmortem CT angiography was combined with autopsy. Conclusion Postmortem CT and postmortem CT angiography and autopsy each detect important lesions not detected by the other method. More lesions were identified by combining postmortem CT angiography and autopsy, which may increase the quality of postmortem diagnosis. Online supplemental material is available for this article.

  8. Pediatric angiography

    International Nuclear Information System (INIS)

    Fitz, A.R.

    1987-01-01

    Angiography of the cerebral and visceral arterial systems is performed much less frequently than it was before the advent of computed tomographic scanning (CT). Most institutions have experienced at least a 50% reduction in the number of angiograms performed since installing a CT scanner. However, angiography still plays an important role in the confirmation of diagnoses made using a scanner, and in providing valuable information to the surgeon prior to excision of tumors or the repair of traumatized organs. Recently a number of sophisticated therapeutic procedures requiring vascular catheterization and the injection of contrast agents have been developed. In these procedures catheters are selectively placed in blood vessels perfusing a pathological process, such as an arteriovenous malformation, or at the site of an arterial stenosis; embolization of the arteriovenous malformation or tumor, or dilatation of the stenotic segment, is then performed. Whether the vessel catheterization is for diagnostic or therapeutic purposes, the basic approach is the same, and the technologist's duties are similar. The principal difference between a diagnostic and a therapeutic procedure is the length of time required to carry out the study; therapeutic procedures often require significantly longer periods of general anesthesia or sedation than do diagnostic studies

  9. Diagnostic accuracy of multi-slice computed tomographic angiography in the detection of cerebral aneurysms

    International Nuclear Information System (INIS)

    Haghighatkhah, H. R.; Sabouri, S.; Borzouyeh, F.; Bagherzadeh, M. H.; Bakhshandeh, H.; Jalali, A. H.

    2008-01-01

    Multislice computed tomographic angiography is a rapid and minimally invasive method for the detection of intracranial aneurysms. The purpose of this study was to compare Multislice computed tomographic angiography with digital subtraction angiography In the diagnosis of cerebral aneurysms. Patients and Methods: In this cross sectional study we evaluated 111 consecutive patients [42(37.8%) male and 69(62.2%) female], who were admitted under clinical symptoms and signs. suggestive of harboring an intracranial aneurysm by using a four detector Multislice computed tomographic angiography. Then we compared results of Multislice computed tomographic angiography with digital subtraction angiography results as a gold standard method. Digital subtraction angiography was performed by bilateral selective common carotid artery injections and either unilateral or bilateral vertebral artery injections, as necessary. Multislice computed tomographic angiography images were interpreted by one radiologist and digital subtraction angiography was performed by another radiologist who was blinded to the interpretation of the Multislice computed tomographic angiograms. Results: The mean ±S D age of the patients was 49.1±13.6 years (range: 12-84 years). We performed Multislice computed tomographic in 111 and digital subtraction angiography in 85 patients. The sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratio of Multislice computed tomographic angiography, when compared with digital subtraction angiography as the gold standard, were 100%, 90%, 87.5%, 100%, 10 and 0, respectively. Conclusion: Multislice computed tomographic angiography seems to be an accurate and noninvasive imaging modality in the diagnosis of intracranial aneurysms

  10. Angiography in renal tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Doo Suk [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1974-10-15

    Angiographies on forty cases of renal tuberculosis performed at the National Medical Center during a period 1960 through 1970 were reviewed. Abdominal angiography was performed via the femoral route. Some were followed by selective nephroangiography. All patients were subjected to urographyior to angiography. The results of X-ray findings in the forty cases with renal tuberculosis were follows. 1. The age varied 18 to 57 years, average 30.5 years. Twenty one patients were male, and nineteen were female. 2. The right kidney was involved in 17 cases and the left in 15 cases. Both kidneys were involved in 8 cases. 3. Urographic examination revealed pathologic changes in all patients. 4. Focal destruction in the collecting system was the most common finding in the urography of 16 patients. 5. A varying degree of hydronephrosis was present in 15 patients, of whom nine had complained of palpable mass due to hydronephrosis. 6. In the 7 patients with extensive destruction there was no observable excretion contrast medium from the diseased kidney. 7. Angiographic examination was normal in 6 of the 40 patients. 8. Decreased vascularity in the subsegmental or smaller arteries of the affected kidney was the most frequent finding, being found in 34 patients. 9. Occlusion or abrupt termination of the subsegmental arteries was present in 4 patients. 10. Eighteen of the patients had signs of an expansive process within the cavity, the vessels being displaced and stretched around the lesions.

  11. Incidence of ischemic lesions in diffusion-weighted imaging after transbrachial digital subtraction angiography

    International Nuclear Information System (INIS)

    Aschenbach, R.; Majeed, A.; Eger, C.; Basche, S.; Kerl, J.M.; Vogl, T.J.

    2008-01-01

    Purpose: to evaluate the frequency of ischemia after transbrachial digital subtraction angiography under ambulant conditions using diffusion-weighted imaging. Materials and methods: 200 patients were included in a prospective study design and received transbrachial digital subtraction angiography under ambulant conditions. Before and after digital subtraction angiography, diffusion-weighted imaging of the brain was performed. Results: in our study population no new lesions were found in diffusion-weighted imaging after digital subtraction angiography during the 3-hour window after angiography. One new lesion was found 3 days after angiography as a late onset complication. Therefore, the frequency of neurological complications is at the level of the confidence interval of 0 - 1.5%. Conclusion: the transbrachial approach under ambulant conditions is a safe method for digital subtraction angiography resulting in a low rate of ischemic lesions in diffusion-weighted imaging. (orig.)

  12. MR angiography in the diagnosis of cerebral venous angiomas: 3D TOF versus phase contrast

    International Nuclear Information System (INIS)

    Choi, Hye Young; Kim, Myung Hyen; Park, Hyung Chun; Lee, Min Hee; Kim, Yoo Kyung; Lee, Sun Wha

    1995-01-01

    To seek adequate sequence of MR angiography (MRA) on developmental venous anomaly in the brain. We collected ten cases who demonstrated developmental venous anomaly on MR image. Eight patients among them, both 3D time-of-fight (TOF) with or without Gadolinium-DTPA enhancement and phase contrast(PC) were performed: TOF without enhancement in five. TOF with enhancement in six, and PC with 10 cm/sec in five, PC with 30 cm/sec in three, and PC with 5 cm/sec velocity encoding (VNEC) in two cases. On enhanced 3D TOF, both dilated collecting veins and medullary veins were well depicted in five of six cases, however, the signal intensity of the collecting and medullary veins are less than arteries. Dilated hyperintense collecting veins were well demonstrated on 3D PC with below the 10 cm/sec VNEC in all seven cases, but the medullary veins were poorly defined. Unenhanced 3D TOF MRA could not reveal any dilated collecting and medullary veins in all five cases. Enhanced 3D TOF could demonstrate the collecting and medullary veins of developmental venous anomaly, however, 3D PC with below the 10 cm/sec VNEC could show the dilated collecting and larger draining veins. We considered that combined enhanced 3D TOF MRA and PC with VENC 10 cm/sec can substitute for conventional angiogram in the diagnosis of developmental venous anomaly

  13. Evaluation of spinal cord vessels using multi-slice CT angiography

    International Nuclear Information System (INIS)

    Chen Shuang; Zhu Ruijiang; Feng Xiaoyuan

    2006-01-01

    Objective: To evaluate the value of Multi-slice spiral CT angiography for spinal cord vessels. Methods: 11 adult subjects with suspected of myelopathy were performed with Multi-slice spiral CT angiography, An iodine contrast agent was injected at 3.5 ml/s, for total 100 ml. The parameters were axial 16 slice mode, 0.625 mm slice thickness, 0.8 s rotation, delay time depending on smartprep(15-25 s), multi-phase scan. The coronal and sagittal MPR and SSD were generated on a workstation compared with spinal digital subtraction angiography (DSA) to analyze normal or abnormal spinal cord vessels. Results: Normal findings at spinal CTA and digital subtraction angiography in six adult normal subjects and spinal cord vascular malformations (1 intradural extramedullary AVF, 4 dural AVFs) in five cases, Recognizable intradural vessels corresponding to anterior median (midline) veins and/or anterior spinal arteries were show in six adult normal subjects. Abnormal intradural vessels were detected in all five spinal cord vascular malformation with CT angiography, in comparison with digital subtraction angiography these vessels were primarily enlarged veins of the coronal venous plexus on the cord surface, radiculomedullary-dural arteries could not be clearly shown in four dural AVF, only one anterior spinal artery was detected in one patient with intradural medullary AVF, which direct shunt between anterior spinal artery and perimedullary vein with tortuous draining vessel. Conclusion: Multi-slice CT angiography is able to visualize the normal or abnormal spinal cord vessels. It could be used as a noninvasive method to screen the spinal cord vascular disease. (authors)

  14. MR angiography in portal hypertension: state of the art

    International Nuclear Information System (INIS)

    Vosshenrich, R.; Fischer, U.; Grabbe, E.

    2001-01-01

    When imaging the portal vascular system colour-coded sonography and CT angiography are used as an alternative to intraarterial DSA. Today fast CE 3D- MRA is the imaging modality of choice in the diagnostic of patients with portal hypertension. It enables a clear picture of the portalvenous vascular system and portalsystemic shunts. Statements regarding velocity and direction of blood flow can be made with additional use of TOF and PC techniques. CE-3D MRA can be used preoperatively before liver transplantation or shunt surgery. In the follow-up of interventional or surgical procedures exact statements concerning haemodynamically significant pathologies e.g. vascular thromboses, stenoses and occlusions can be made. Patient consent is symplify and the numbers of complications can be reduced as well as duration of surgery minimized applying this technique (orig.) [de

  15. Whole-Body MR Imaging Including Angiography: Predicting Recurrent Events in Diabetics.

    Science.gov (United States)

    Bertheau, Robert C; Bamberg, Fabian; Lochner, Elena; Findeisen, Hannes M; Parhofer, Klaus G; Kauczor, Hans-Ulrich; Schoenberg, Stefan O; Weckbach, Sabine; Schlett, Christopher L

    2016-05-01

    Whether whole-body MRI can predict occurrence of recurrent events in patients with diabetes mellitus. Whole-body MRI was prospectively applied to 61 diabetics and assessed for arteriosclerosis and ischemic cerebral/myocardial changes. Occurrence of cardiocerebral events and diabetic comorbidites was determined. Patients were stratified whether no, a single or recurrent events arose. As a secondary endpoint, events were stratified into organ system-specific groups. During a median follow-up of 70 months, 26 diabetics developed a total of 39 events; 18 (30%) developed one, 8 (13%) recurrent events. Between diabetics with no, a single and recurrent events, a stepwise higher burden was observed for presence of left ventricular (LV) hypo-/akinesia (3/28/75%, p < 0.0001), myocardial delayed-contrast-enhancement (17/33/63%, p = 0.001), carotid artery stenosis (11/17/63%, p = 0.005), peripheral artery stenosis (26/56/88%, p = 0.0006) and vessel score (1.00/1.30/1.76, p < 0.0001). After adjusting for clinical characteristics, LV hypo-/akinesia (hazard rate ratio = 6.57, p < 0.0001) and vessel score (hazard rate ratio = 12.29, p < 0.0001) remained independently associated. Assessing organ system risk, cardiac and cerebral MR findings predicted more strongly events in their respective organ system. Vessel-score predicted both cardiac and cerebral, but not non-cardiocerebral, events. Whole-body MR findings predict occurrence of recurrent events in diabetics independent of clinical characteristics, and may concurrently provide organ system-specific risk. • Patients with long-standing diabetes mellitus are at high risk for recurrent events. • Whole-body MRI predicts occurrence of recurrent events independently of clinical characteristics. • The vessel score derived from whole-body angiography is a good general risk-marker. • Whole-body MRI may also provide organ-specific risk assessment. • Current findings may indicate benefits of

  16. Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Yoon [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Severance Hospital, Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Seoul (Korea, Republic of); Kim, Chan Kyo; Park, Byung Kwan [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Kim, EunJu [Philips Healthcare Korea, Seoul (Korea, Republic of)

    2014-09-13

    To investigate the feasibility of noncontrast-enhanced MR angiography (NC-MRA) using the repetitive artery and venous labelling (RAVEL) technique to evaluate renal arteries compared to contrast-enhanced MR angiography (CE-MRA). Twenty-five subjects with normal renal function underwent NC-MRA using a RAVEL technique and CE-MRA at 3 T. Two independent readers analysed the MRA images. Image quality, number of renal arteries, presence or absence of an early branching vessel, and diameter of the main renal arteries were evaluated. The overall image quality of NC-MRA was fair or greater in 88 % of right and 92 % of left renal arteries, while it was 96 % in both sides with CE-MRA. On NC-MRA, the number of renal arteries in all subjects was perfectly predicted by both readers. Sensitivity and specificity for predicting early branching vessels were 82 % and 100 % for reader 1 and 82 % and 95 % for reader 2. Inter-modality agreement for comparing the diameters of main renal arteries was good or excellent at all segments for both readers. Inter-reader agreement was moderate or good at all segments except at the right distal segment on NC-MRA. NC-MRA with the RAVEL technique at 3 T may have comparable diagnostic feasibility for evaluating renal arteries compared to CE-MRA. (orig.)

  17. Clinical utility and cost-effectiveness of CT-angiography in the diagnosis of nontraumatic subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Jabbarli, Ramazan; Shah, Mukesch; Hippchen, Beate; Velthoven, Vera van [University Hospital of Freiburg, Department of Neurosurgery, Freiburg/Breisgau (Germany); Taschner, Christian [University Hospital of Freiburg, Department of Neuroradiology, Freiburg (Germany); Kaier, Klaus [University Hospital of Freiburg, Institute for Medical Biometry and Medical Informatics, Freiburg (Germany)

    2014-10-15

    CT-angiography gains an increasing role in the initial diagnosis of patients with nontraumatic subarachnoid hemorrhage (SAH). However, the implementation of CT-angiography does not always exclude the necessity of conventional angiography. Our objective was to determine the practical utility and cost-effectiveness of CT-angiography. All patients with nontraumatic subarachnoid hemorrhage admitted to our university hospital after implementation of CT-angiography between June 1, 2011 and June 30, 2012 were retrospectively analyzed in regard to factors of treatment flow, radiation exposure, harms of contrast medium loading, and diagnostic costs. A control group of the same size was assembled from previously admitted SAH patients, who did not undergo pretreatment CT-angiography. Furthermore, cost-effectiveness analysis was performed. The final analysis consisted of 93 patients in each group. Of 93 patients with pretreatment CT-angiography, 74 had to undergo conventional angiography for diagnostic and/or therapeutic purposes. CT-angiography had significant impact on the reduction of collective effective radiation dose by 4.419 mSv per person (p = 0.0002) and was not associated with additional harms. Despite the significantly earlier detection of aneurysms with CT-angiography (p < 0.0001), there were no significant differences in the timing of aneurysm repair and duration of ICU and general hospital stay. There was an increase of diagnostic costs - the cost-effectiveness analysis showed, however, that benefits of CT-angiography in respect to radiation exposure and risk of conventional angiography-related complications justify the additional costs of CT-angiography. Although the implementation of CT-angiography in SAH diagnosis cannot completely replace conventional angiography, it can be approved in regard to radiation hygiene and cost-effectiveness. (orig.)

  18. Magnetic resonance angiography of fetal vasculature at 3.0 T

    OpenAIRE

    Neelavalli, Jaladhar; Krishnamurthy, Uday; Jella, Pavan K.; Mody, Swati S.; Yadav, Brijesh K.; Hendershot, Kelly; Hernandez-Andrade, Edgar; Yeo, Lami; Cabrera, Maria D.; Haacke, Ewart M.; Hassan, Sonia S.; Romero, Roberto

    2016-01-01

    Magnetic resonance angiography has not been used much previously for visualizing fetal vessels in utero for reasons that include a contraindication for the use of exogenous contrast agents, maternal respiratory motion and fetal motion. In this work, we report the feasibility of using an appropriately modified clinical time-of-flight magnetic resonance imaging sequence for non-contrast angiography of human fetal and placental vessels at 3.0 T. Using this 2D angiography technique, it is possibl...

  19. Branching pattern of lenticulostriate arteries observed by MR angiography at 3.0 T

    International Nuclear Information System (INIS)

    Akashi, Toshiaki; Taoka, Toshiaki; Ochi, Tomoko; Miyasaka, Toshiteru; Wada, Takeshi; Sakamoto, Masahiko; Kichikawa, Kimihiko; Takewa, Megumi

    2012-01-01

    We hypothesized that the pattern of branching of the lenticulostriate arteries (LSAs) is involved in the variation of the distribution of the infarction within the LSA region. Our purpose was to evaluate the visibility of LSAs in 3D time-of-flight (TOF) MR angiography (MRA) with a 3.0 T scanner and to investigate the branching patterns of LSAs. We performed 3D TOF MRA at 3.0 T for 100 healthy subjects. We assessed the number of LSAs and the number of branches arising from each LSA by evaluating MRA source images. In 200 hemispheres, 330 LSAs were visualized (mean=1.65/hemisphere). In 3.5% of all hemispheres, no LSA was depicted; one LSA was depicted in 39%, two in 46.5%, and three in 11%. The maximum number of depicted LSA branches was five in 2% of all subjects, four in 7%, three in 26%, and two in 49% (mean=2.3/subject). A large LSA trunk with three or more branches was found in 35% of subjects. Visualization of LSAs was possible in 96.5% of subjects by use of 3.0 T MRA. LSA branching patterns were variable, and a large LSA trunk with three or more branches was common. (author)

  20. Diagnostic accuracy of CT angiography in acute gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Chua, A. E.; Ridley, L. J.

    2008-01-01

    Full text: The aim of the study was to carry out a systematic review determining the accuracy of CT angiography in the diagnosis of acute gastrointestinal bleeding. A search of published work in Medline and manual searching of reference lists of articles was conducted. Studies were included if they compared CT angiography to a reference standard of upper gastrointestinal endoscopy, colonoscopy, angiography or surgery in the diagnosis of acute gastrointestinal bleeding. Eight published studies evaluating 129 patients were included. Data were used to form 2 x2 tables. Computed tomography angiography showed pooled sensitivity of 86% (95% confidence interval 78-92%) and specificity of 95% (95% confidence interval 76-100%), without showing significant heterogeneity (x 2 = 3.5, P=0.6) and (x 2 - 5.4, P = 0.6), respectively. Summary receiver operating characteristic analysis showed an area under the curve of 0.93. Computed tomography angiography is accurate in the diagnosis of acute gastrointestinal bleeding and can show the precise location and aetiology of bleeding, thereby directing further management. Strong recommendations for use of CT cannot be made from this review because of the methodological limitations and further large prospective studies are needed to define the role of CT in acute gastrointestinal bleeding.

  1. Radiosurgery for arteriovenous malformations based on magnetic resonance angiography

    International Nuclear Information System (INIS)

    Mehta, Minesh; Kubsad, Shrikant; Petereit, Daniel; Turski, Patrick; Levin, Allan; Kinsella, Timothy

    1993-01-01

    Magnetic Resonance Angiography (MRA) was performed to establish its feasibility, compare it with standard angiography (SA), employ MRA in follow-up and semiquantify AVM flow velocity (FV). A correlative evaluation between flow velocity and response to stereotactic radiosurgery was also attempted. (author). 8 refs., 1 tab

  2. CT angiography versus 3D rotational angiography in patients with subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Bechan, R.S.; Peluso, J.P.; Sluzewski, M.; Rooij, W.J. van [Sint Elisabeth Ziekenhuis Tilburg, Department of Radiology, Tilburg (Netherlands); Rooij, S.B. van [Medisch Centrum Alkmaar, Department of Radiology, Alkmaar (Netherlands); Sprengers, M.E.; Majoie, C.B. [Academisch Medisch Centrum, Department of Radiology, Amsterdam (Netherlands)

    2015-12-15

    CT angiography (CTA) is increasingly used as primary diagnostic tool to replace digital subtraction angiography (DSA) in patients with subarachnoid hemorrhage (SAH). However, 3D rotational angiography (3DRA) has substituted DSA as a reference standard. In this prospective observational study, we compare CTA with 3DRA of all cerebral vessels in a large cohort of patients with SAH. Of 179 consecutive patients with SAH admitted between March 2013 and July 2014, 139 underwent 64- to 256-detector row CTA followed by complete cerebral 3DRA within 24 h. In 86 patients (62 %), 3DRA was performed under general anesthesia. Two observers from outside hospitals reviewed CTA data. In 118 of 139 patients (85 %), 3DRA diagnosed the cause of hemorrhage: 113 ruptured aneurysms, three arterial dissections, one micro-arteriovenous malformation (AVM), and one reversible vasoconstriction syndrome. On CTA, both observers missed all five non-aneurysmal causes of SAH. Sensitivity of CTA in depicting ruptured aneurysms was 0.88-0.91, and accuracy was 0.88-0.92. Of 113 ruptured aneurysms, 28 were ≤3 mm (25 %) and of 95 additional aneurysms, 71 were ≤3 mm (75 %). Sensitivity of depicting aneurysms ≤3 mm was 0.28-0.43. Of 95 additional aneurysms, the two raters missed 65 (68 %) and 58 (61 %). Sensitivity in detection was lower in aneurysms of the internal carotid artery than in other locations. CTA had some limitations as primary diagnostic tool in patients with SAH. All non-aneurysmal causes for SAH and one in ten ruptured aneurysms were missed. Performance of CTA was poor in aneurysms ≤3 mm. The majority of additional aneurysms were not depicted on CTA. (orig.)

  3. 3D Deep Learning Angiography (3D-DLA) from C-arm Conebeam CT.

    Science.gov (United States)

    Montoya, J C; Li, Y; Strother, C; Chen, G-H

    2018-05-01

    Deep learning is a branch of artificial intelligence that has demonstrated unprecedented performance in many medical imaging applications. Our purpose was to develop a deep learning angiography method to generate 3D cerebral angiograms from a single contrast-enhanced C-arm conebeam CT acquisition in order to reduce image artifacts and radiation dose. A set of 105 3D rotational angiography examinations were randomly selected from an internal data base. All were acquired using a clinical system in conjunction with a standard injection protocol. More than 150 million labeled voxels from 35 subjects were used for training. A deep convolutional neural network was trained to classify each image voxel into 3 tissue types (vasculature, bone, and soft tissue). The trained deep learning angiography model was then applied for tissue classification into a validation cohort of 8 subjects and a final testing cohort of the remaining 62 subjects. The final vasculature tissue class was used to generate the 3D deep learning angiography images. To quantify the generalization error of the trained model, we calculated the accuracy, sensitivity, precision, and Dice similarity coefficients for vasculature classification in relevant anatomy. The 3D deep learning angiography and clinical 3D rotational angiography images were subjected to a qualitative assessment for the presence of intersweep motion artifacts. Vasculature classification accuracy and 95% CI in the testing dataset were 98.7% (98.3%-99.1%). No residual signal from osseous structures was observed for any 3D deep learning angiography testing cases except for small regions in the otic capsule and nasal cavity compared with 37% (23/62) of the 3D rotational angiographies. Deep learning angiography accurately recreated the vascular anatomy of the 3D rotational angiography reconstructions without a mask. Deep learning angiography reduced misregistration artifacts induced by intersweep motion, and it reduced radiation exposure

  4. Pulmonary angiography with lopamidol 370

    International Nuclear Information System (INIS)

    Braun, S.D.; Saeed, M.; Perlmutt, L.M.; Newman, G.E.; Illescas, F.F.; Cohan, R.H.; Dunnick, N.R.

    1986-01-01

    Fifty-one consecutive patients who underwent pulmonary angiography with iopamidol, 370 mg/ml, were studied prospectively. Patients were asked to grade any heat or pain felt on injection, and were observed for coughing. Right atrial and pulmonary artery pressures were obtained before the first and after the final contrast agent injection. Pressure changes were compared with those in a consecutive group of 25 patients who underwent examinations performed with Na-meglumine diatrizoate, 370 mg/ml. Film quality was evaluated for patient motion. Iopamidol generated marked discomfort in only three patients. Pressure changes were largely unremarkable. In no case was there any significant motion artifact secondary to coughing. Iopamidol is a safe, well-tolerated contrast agent for pulmonary angiography. It improves image quality by nearly eliminating coughing

  5. Noninvasive follow-up of GDC-treated saccular aneurysms by MR angiography

    International Nuclear Information System (INIS)

    Weber, W.; Henkes, H.; Nahser, H.C.; Roer, N.; Kuehne, D.; Yousry, T.A.; Felber, S.R.

    2001-01-01

    The aim of this study was to determine sensitivity and specificity of magnetic resonance angiography (MRA) for the assessment of durable occlusion of intracranial aneurysms with Guglielmi detachable coils (GDC) and to point out the influence of MRA results in re-intervention strategies. Forty-five patients with 54 aneurysms that were previously treated by endovascular occlusion with GDC were selected for this study. All patients underwent digital subtraction angiography (DSA) and MRA examinations on the same day. The time-of-flight MRA studies were performed on a 1-T scanner. The MRA images were first read by radiologists who were not aware of the DSA results. In a second consensus reading by the neuroradiologists who had performed all interventional procedures of this series, the decision was made as to whether re-treatment was necessary. The distribution of aneurysm sizes, configurations and treatment results were sufficient for an unbiased evaluation. The first blinded evaluation revealed a sensitivity of 71% and a specificity of 95% for MRA assessment of aneurysm reperfusion. In the second consensus reading, the sensitivity increased to 92% and the specificity was 98%. The blinded reading indicates that MRA is a useful adjunct to DSA for the assessment of durable results after endovascular treatment of intracranial aneurysms. In the consensus reading it became obvious that sensitivity and specificity of MRA can be increased to 92 and 98%, respectively, if the results were evaluated by experienced neuroradiologists, including prior knowledge of all other examinations. We have already increased the follow-up intervals for DSA and use MRA intermittently, based on these results. (orig.)

  6. 2D time-of-flight MR angiography using concatenated saturation bands for determining direction of flow in the intracranial vessels

    International Nuclear Information System (INIS)

    Nesbit, G.M.; DeMarco, J.K.

    1997-01-01

    We prospectively studied 15 patients to assess 2D time-of-flight (TOF) magnetic resonance angiography (MRA) with concatenated saturation bands for determining the direction of intracranial blood flow. This MRA sequence was compared to T2-weighted spin-echo MRI, 3D-TOF MRA, and intra-arterial angiography (IAA) as regards demonstration of vessels and determination of the direction of flow in the circle of Willis and its branches. The 2D-TOF MRA sequence demonstrated flow in 98.5 % vessel segments identified on IAA, 3D-TOF demonstrating 92 % and spin-echo images 77 %. The direction of flow shown on the 2D-TOF sequence was correct in 94 % when compared to conventional angiography, the remaining six segments not demonstrating flow. In ten patients, the flow abnormalities demonstrated by this MRA technique provided clinical information similar to that of conventional angiography in nine, but it was incomplete in three, and misleading in one. Slow retrograde flow in ophthalmic artery collaterals and differentiation of arteries and veins presented some problems. 2D-TOF MRA with concatenated saturation bands provides flow direction information using widely available, easily applicable TOF techniques, and can be a useful adjunct to MRI and MRA if information on flow direction is needed. (orig.). With 5 figs., 3 tabs

  7. Supra-aortic low-dose contrast-enhanced time-resolved magnetic resonance (MR) angiography at 3 T: comparison with time-of-flight MR angiography and high-resolution contrast-enhanced MR angiography.

    Science.gov (United States)

    Lee, Youn-Joo; Kim, Bum-soo; Koo, Ja-Sung; Kim, Bom-Yi; Jang, Jinhee; Choi, Hyun Seok; Jung, So-Lyung; Ahn, Kook-Jin

    2015-06-01

    Low-dose, time-resolved, contrast-enhanced, magnetic resonance angiography (TR-CEMRA) has been described previously; however, a comparative study between low dose TR-CEMRA and time-of-flight MRA (TOF-MRA) in the diagnosis of supra-aortic arterial stenosis has not yet been published. To demonstrate the feasibility and effectiveness of low-dose TR-CEMRA compared with TOF-MRA, using high-resolution contrast-enhanced MRA (HR-CEMRA) as the reference standard. This prospective study consisted of 30 consecutive patients. All patients underwent TOF-MRA of the neck and circle of Willis and supra-aortic HR-CEMRA, followed by supra-aortic low-dose TR-CEMRA. Gadoterate meglumine (Gd-DOTA, Dotarem(®), Guerbet, Roissy CdG Cedex, France) was injected at a dose of 0.1 mmol/kg for HR-CEMRA, followed by a 0.03 mmol/kg bolus for low-dose TR-CEMRA. Three readers evaluated the assessibility and image quality, and then two readers classified each stenosis into the following categories: normal (0-30%), mild stenosis (31-50%), moderate (51-70%), severe (71-99%), and occlusion. TR-CEMRA and HR-CEMRA showed a greater number of assessable arterial segments than TOF-MRA (P supra-aortic arterial stenosis, and could be more useful option than TOF-MRA. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  8. Combined use of intraarterial digital subtraction angiography with conventional retrograde brachial vertebral angiography

    International Nuclear Information System (INIS)

    Yamaguchi, Tatsuo; Ogawa, Toshihide; Inugami, Atsushi; Kawata, Yasushi; Shishido, Fumio; Uemura, Kazuo

    1985-01-01

    For 102 patients who had the examination of conventional bilaterally retrograde brachial vertebral angiography (retrograde VAG), intraarterial digital subtraction angiography (DSA) was successively performed to investigate steno-occlusive lesions of proximal vertebral and subclavian arteries. All the patients had no complication due to the DSA procedure. In 50% of 72 ischemic stroke cases, positive findings were found either in the origin of the vertebral artery or in the subclavian artery. Stenosis of more than 50% of the lumen of the vertebral artery were found in 14% of the cases at the origin of the right one and also in 14% in the left one. Occlusion of the vertebral artery was found in 4% in the left side only. In 30 cases with non-ischemic brain diseases, positive findings were noted in 10%. Intraarterial DSA combined with retrograde VAG was thought to be useful, especially in the examination for ischemic stroke. (author)

  9. Poststenotic signal attenuation on 3 D phase-contrast MR angiography: a useful finding in haemodynamically significant carotid artery stenosis

    International Nuclear Information System (INIS)

    Iseda, T.; Nakano, S.; Miyahara, D.; Uchinokura, S.; Goya, T.; Wakisaka, S.

    2000-01-01

    We performed blinded visual evaluation of MR angiography (MRA) films in 44 patients with unilateral carotid artery stenosis to determine whether a flow gap and poststenotic signal attenuation on 3 D-PC MRA were useful signs of severe carotid artery stenosis. Although nine patients with a flow gap alone had various degrees of stenosis ranging from 22.2 to 77.3 % without any decrease in regional cerebral blood flow (rCBF), 13 patients with both a flow gap and poststenotic signal attenuation had severe stenoses of 80 % or more, with a definite decrease in baseline rCBF. The presence of both a flow gap and poststenotic signal attenuation on 3 D-PC MRA appeared to be a reliable marker of severe carotid artery stenosis with a decrease in rCBF. (orig.)

  10. Subtraction MR venography acquired from time-resolved contrast-enhanced MR angiography: Comparison with phase-contrast MR venography and single-phase contrast-enhanced MR venography

    International Nuclear Information System (INIS)

    Jang, Jin Hee; Kim, Bum Soo; KIm, Bom Yi; Choi, Hyun Seok; Jung, So Lyung; Ahn, Kook Jin; Sung, Ji Kyeong

    2015-01-01

    To evaluate the image characteristics of subtraction magnetic resonance venography (SMRV) from time-resolved contrast-enhanced MR angiography (TRMRA) compared with phase-contrast MR venography (PCMRV) and single-phase contrast-enhanced MR venography (CEMRV). Twenty-one patients who underwent brain MR venography (MRV) using standard protocols (PCMRV, CEMRV, and TRMRA) were included. SMRV was made by subtracting the arterial phase data from the venous phase data in TRMRA. Co-registration and subtraction of the two volume data was done using commercially available software. Image quality and the degree of arterial contamination of the three MRVs were compared. In the three MRVs, 19 pre-defined venous structures (14 dural sinuses and 5 cerebral veins) were evaluated. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the three MRVs were also compared. Single-phase contrast-enhanced MR venography showed better image quality (median score 4 in both reviewers) than did the other two MRVs (p < 0.001), whereas SMRV (median score 3 in both reviewers) and PCMRV (median score 3 in both reviewers) had similar image quality (p ≥ 0.951). SMRV (median score 0 in both reviewers) suppressed arterial signal better than did the other MRVs (median score 1 in CEMRV, median score 2 in PCMRV, both reviewers) (p < 0.001). The dural sinus score of SMRV (median and interquartile range [IQR] 48, 43-50 for reviewer 1, 47, 43-49 for reviewer 2) was significantly higher than for PCMRV (median and IQR 31, 25-34 for reviewer 1, 30, 23-32 for reviewer 2) (p < 0.01) and did not differ from that of CEMRV (median and IQR 50, 47-52 for reviewer 1, 49, 45-51 for reviewer 2) (p = 0.146 in reviewer 1 and 0.123 in reviewer 2). The SNR and CNR of SMRV (median and IQR 104.5, 83.1-121.2 and 104.1, 74.9-120.5, respectively) were between those of CEMRV (median and IQR 150.3, 111-182.6 and 148.4, 108-178.2) and PCMRV (median and IQR 59.4, 49.2-74.9 and 53.6, 43.8-69.2). Subtraction magnetic

  11. Magnetic resonance angiography of fetal vasculature at 3.0 T

    Science.gov (United States)

    Krishnamurthy, Uday; Jella, Pavan K.; Mody, Swati S.; Yadav, Brijesh K.; Hendershot, Kelly; Hernandez-Andrade, Edgar; Yeo, Lami; Cabrera, Maria D.; Haacke, Ewart M.; Hassan, Sonia S.; Romero, Roberto

    2016-01-01

    Magnetic resonance angiography has not been used much previously for visualizing fetal vessels in utero for reasons that include a contraindication for the use of exogenous contrast agents, maternal respiratory motion and fetal motion. In this work, we report the feasibility of using an appropriately modified clinical time-of-flight magnetic resonance imaging sequence for non-contrast angiography of human fetal and placental vessels at 3.0 T. Using this 2D angiography technique, it is possible to visualize fetal vascular networks in late pregnancy. PMID:27189488

  12. Magnetic resonance angiography of fetal vasculature at 3.0 T

    International Nuclear Information System (INIS)

    Neelavalli, Jaladhar; Krishnamurthy, Uday; Yadav, Brijesh K.; Haacke, Ewart M.; Jella, Pavan K.; Hendershot, Kelly; Cabrera, Maria D.; Mody, Swati S.; Hernandez-Andrade, Edgar; Yeo, Lami; Hassan, Sonia S.; Romero, Roberto

    2016-01-01

    Magnetic resonance angiography has not been used much previously for visualizing fetal vessels in utero for reasons that include a contraindication for the use of exogenous contrast agents, maternal respiratory motion and fetal motion. In this work, we report the feasibility of using an appropriately modified clinical time-of-flight magnetic resonance imaging sequence for non-contrast angiography of human fetal and placental vessels at 3.0 T. Using this 2D angiography technique, it is possible to visualize fetal vascular networks in late pregnancy. (orig.)

  13. Magnetic resonance angiography of fetal vasculature at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Neelavalli, Jaladhar; Krishnamurthy, Uday; Yadav, Brijesh K.; Haacke, Ewart M. [Wayne State University School of Medicine, Department of Radiology, Detroit, MI (United States); Wayne State University, Department of Biomedical Engineering, Detroit, MI (United States); Jella, Pavan K.; Hendershot, Kelly; Cabrera, Maria D. [Wayne State University School of Medicine, Department of Radiology, Detroit, MI (United States); Mody, Swati S. [Wayne State University School of Medicine, Department of Radiology, Detroit, MI (United States); Children' s Hospital of Michigan, Department of Radiology, Detroit, MI (United States); Hernandez-Andrade, Edgar; Yeo, Lami; Hassan, Sonia S. [Wayne State University, Department of Obstetrics and Gynecology, Detroit, MI (United States); Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD, and Detroit, MI (United States); Romero, Roberto [Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD, and Detroit, MI (United States); University of Michigan, Department of Obstetrics and Gynecology, Ann Arbor, MI (United States); Michigan State University, Department of Epidemiology and Biostatistics, East Lansing, MI (United States); Wayne State University, Center for Molecular Medicine and Genetics, Detroit, MI (United States)

    2016-12-15

    Magnetic resonance angiography has not been used much previously for visualizing fetal vessels in utero for reasons that include a contraindication for the use of exogenous contrast agents, maternal respiratory motion and fetal motion. In this work, we report the feasibility of using an appropriately modified clinical time-of-flight magnetic resonance imaging sequence for non-contrast angiography of human fetal and placental vessels at 3.0 T. Using this 2D angiography technique, it is possible to visualize fetal vascular networks in late pregnancy. (orig.)

  14. Three dimensional CT angiography (3D-CTA) in ruptured aneurysm surgery on acute stage

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Endo, Yuji; Nakano, Masayuki

    1998-01-01

    We evaluated three-dimensional CT angiography (3D-CTA) for the treatment of acutely ruptured cerebral aneurysms. Sixty patients with subarachnoid hemorrhage from cerebral aneurysms were investigated both by 3D-CTA and conventional angiography and 26 patients were studied using 3D-CTA without conventional angiography. In the 60 cases, both 3D-CTA and the conventional angiography revealed 100% accuracy in diagnosing ruptured aneurysms, and 3D-CTA and the conventional angiography showed 96% and 92% accuracy for unruptured aneurysms respectively. 3D-CTA was equal or superior to the conventional angiography. Based on these data, since December, 1996, we have operated on 26 consecutive patients with ruptured aneurysms located in the anterior circulation of the circle of Willis, using 3D-CTA without conventional angiography. Thirty-one aneurysms, including 5 associated unruptured aneurysms, were visualized by 3D-CTA and verified at surgery. All aneurysms were clipped successfully. We think that it will be possible to operate on most ruptured aneurysms using only 3D-CTA without the conventional angiography except for the cases of the following situations: if a cerebral infarction is present, conventional angiography is required to evaluate for a stenotic or occlusive lesion of the intracranial arteries, cervical carotid, or vertebral arteries; in cases of giant or large aneurysms, the dynamic information provided by the conventional angiography is needed in case bypass surgery is necessary; and for aneurysms close to bony structures, such as an internal carotid-ophthalmic artery aneurysm, conventional angiography is necessary. (author)

  15. Three-dimensional coronary MR angiography with continuous administration of Gd-DTPA. Delineation and detection of coronary artery stenosis

    International Nuclear Information System (INIS)

    Yokoyama, Kenichi

    1999-01-01

    Three-dimensional coronary MR angiography (3D coronary MRA) with Gd-DTPA administration was performed in 19 patients to evaluate the vascular delineation and diagnostic capability for stenotic lesions. A 3D fast low-angle shot (FLASH) with a navigator echo respiratory gating technique was used with a superconducting 1.5 tesla MR system (Vision, Siemens Medical Systems, Erlangen, Germany). Administration of the conventional T 1 contrast agent with extra-cellular distribution produced a significant increase in the SNR and CNR of the proximal coronary arterial images. Visual score of both the source images and the multiplanar reconstruction (MPR) images assessed by three radiologists was superior to those on control images (without contrast enhancement). The MRA findings of stenotic lesions of the coronary artery were compared with the results of the conventional coronary angiographic study. Overall sensitivity and specificity for the detection of stenosis were almost the same as those of control images. In conclusion, 3D coronary MRA with Gd-DTPA administration improved coronary artery delineation. However, further technical improvements are required to enhance the value of the technique in detecting stenoses. (author)

  16. Magnetic resonance angiography of arteriovenous malformation in the thalamus

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Hirofumi; Kida, Yoshihisa; Kobayashi, Tatsuya; Tanaka, Takayuki; Iwakoshi, Takayasu; Kai, Osamu; Hirose, Mitsuhiko [Komaki City Hospital, Aichi (Japan)

    1993-11-01

    A comparative study of magnetic resonance angiography and conventional angiography of arteriovenous malformation in the thalamus showed that both methods clearly visualized the feeding arteries: perforating branches of the posterior cerebral artery, posterior choroidal artery and lenticulostriate artery. Draining veins such as the internal cerebral vein were also demonstrated well. (author).

  17. The evaluation of a formalized queue management system for coronary angiography waiting lists.

    Science.gov (United States)

    Alter, D A; Newman, Alice M; Cohen, Eric A; Sykora, Kathy; Tu, Jack V

    2005-11-01

    Lengthy waiting lists for coronary angiography have been described in many health care systems worldwide. The extent to which formal queue management systems may improve the prioritization and survival of patients in the angiography queue is unknown. To prospectively evaluate the performance of a formal queue management system for patients awaiting coronary angiography in Ontario. The coronary angiography urgency scale, a formal queue management system developed in 1993 using a modified Delphi panel, allocates recommended maximum waiting times (RMWTs) in accordance with clinical necessity. By using a provincial clinical registry, 35,617 consecutive patients referred into the coronary angiography queue between April 1, 2001, and March 31, 2002, were prospectively tracked. Cox proportional hazards models were used to examined mortality risk across urgency after adjusting for additional clinical and comorbid factors. Good agreement was determined in urgency ratings between scores from the coronary angiography urgency scale and implicit physician judgement, which was obtained independently at the time of the index referral (weighted kappa = 0.49). The overall mortality in the queue was 0.3% (0.47%, 0.26% and 0.13% for urgent, semiurgent and elective patients, respectively). Urgency, as specified by the coronary angiography urgency scale, was the strongest predictor of death in the queue (Pqueue management system may decrease mortality in the coronary angiography queue. The authors recommend its implementation in health care systems where patients experience excessive waiting time delays for coronary angiography.

  18. Gallbladder visualization on CT shortly after angiography with ioxaglate

    International Nuclear Information System (INIS)

    Tajima, H.; Kaizu, T.; Ichikawa, T.; Kumazaki, T.

    1994-01-01

    Thirty-five patients underwent CT examination 15 to 30 min after abdominal angiography with ioxaglate. The gallbladder was visualized in 12 patients in the absence of clinical evidence of renal impairment. Gallbladder opacification on CT examinations shortly after angiography shows that the hepatobiliary tract is important in the excretion of ioxaglate. (orig.)

  19. Fluorine cardiovascular magnetic resonance angiography in vivo at 1.5 T with perfluorocarbon nanoparticle contrast agents.

    Science.gov (United States)

    Neubauer, Anne M; Caruthers, Shelton D; Hockett, Franklin D; Cyrus, Tillman; Robertson, J David; Allen, J Stacy; Williams, Todd D; Fuhrhop, Ralph W; Lanza, Gregory M; Wickline, Samuel A

    2007-01-01

    While the current gold standard for coronary imaging is X-ray angiography, evidence is accumulating that it may not be the most sensitive technique for detecting unstable plaque. Other imaging modalities, such as cardiovascular magnetic resonance (CMR), can be used for plaque characterization, but suffer from long scan and reconstruction times for determining regions of stenosis. We have developed an intravascular fluorinated contrast agent that can be used for angiography with cardiovascular magnetic resosnace at clinical field strengths (1.5 T). This liquid perfluorocarbon nanoparticle contains a high concentration of fluorine atoms that can be used to generate contrast on 19F MR images without any competing background signal from surrounding tissues. By using a perfluorocarbon with 20 equivalent fluorine molecules, custom-built RF coils, a modified clinical scanner, and an efficient steady-state free procession sequence, we demonstrate the use of this agent for angiography of small vessels in vitro, ex vivo, and in vivo. The surprisingly high signal generated with very short scan times and low doses of perfluorocarbon indicates that this technique may be useful in clinical settings when coupled with advanced imaging strategies.

  20. Comparison of magnetic resonance angiography and conventional angiography in sickle cell disease: clinical significance and realibility

    International Nuclear Information System (INIS)

    Kandeel, A.Y.; Zimmerman, R.A.; Ohene-Frempong, K.

    1996-01-01

    We retrospectively reviewed the medical records and conventional angiograms of 21 patients with known sickle cell disease, who underwent a total of 50 magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) studies. MRA and conventional angiography were assessed separately for evidence of stenosis or occulusion. Follow up MRI/MRA studies were also assessed for evidence of progression, regression or stability of the disease in these patients. In the carotid circulation, MRA made the correct diagnosis in 85% of the vessels evaluated with a sensitivity of 80.5% and a specificity of 94%. MRA was also found to show evidence of disease progression, more often than did MRI or the clinical condition of the patients. (orig.)

  1. Diagnostic value of multislice computed tomography angiography in coronary artery disease: A meta-analysis

    International Nuclear Information System (INIS)

    Sun Zhonghua; Jiang Wen

    2006-01-01

    Purpose: To perform a meta-analysis of the diagnostic value of multislice CT (MSCT) angiography in the detection of coronary artery disease (CAD) when compared to conventional coronary angiography. Materials and methods: A search of PubMed and MEDLINE databases for English literature was performed. Only studies with at least 10 patients comparing MSCT angiography with conventional coronary angiography in the detection of CAD were included. Diagnostic value of MSCT angiography compared to coronary angiography was compared and analyzed at segment-, vessel- and patient-based assessment. Results: 47 studies (67 comparisons) met the criteria and were included in our study. Pooled overall sensitivity, specificity and 95% confidence interval for MSCT angiography in the detection of CAD were 83% (79%, 89%), 93% (91%, 96%) at segment-based analysis; 90% (87%, 94%), 87% (80%, 93%) at vessel-based analysis; and 91% (88%, 95%), 86% (81%, 92%) at patient-based analysis, respectively. Diagnostic accuracy of MSCT angiography in evaluating assessable segments was significantly improved with 64-slice scanners when compared to that with 4- and 16-slice scanners (p < 0.05). Conclusion: Our meta-analysis showed that MSCT angiography has potential diagnostic accuracy in the detection of CAD. Diagnostic performance of MSCT angiography has been significantly improved with the latest 64-slice CT, with resultant high qualitative and quantitative diagnostic accuracy. 16-slice CT was limited in spatial resolution which makes it difficult to perform quantitative assessment of coronary artery stenoses

  2. Contrast-enhanced 3D MR angiography of the chest and abdomen with breath-holding using phase reordering

    International Nuclear Information System (INIS)

    Amanuma, Makoto; Sugimoto, Eiichi; Enomoto, Kyoko; Watabe, Tsuneya; Heshiki, Atsuko; Hirata, Hisashi; Kimura, Toshihiko; Takizawa, Osamu.

    1995-01-01

    This report presents the feasibility of phase-reordered contrast-enhanced three-dimensional MR angiography in 32 consecutive patients with vascular abnormalities in the chest and abdomen. To suppress motion artifacts due to respiratory corruption, a phase-reordering technique was introduced so that the low frequency components of the phase data were obtained first during the imaging period. Image quality and degree of motion suppression were assessed by four radiologists independently without information on breath-holding time. Abnormalities were detected in 30 cases (93.8%), and their extent was correctly assessed in 28 cases (87.5%). More confident assessment was possible in abnormalities of the pulmonary vessels and thoracic aorta than in those of the abdominal aorta and portal venous system. With phase reordering, more than 20 seconds of breath-holding ensured image quality sufficient to correctly assess the vascular abnormalities. While this technique is easy and requires only single breath-holding, it can provide excellent MRA without slice-to-slice spatial misregistration. (author)

  3. Correlation between coronary computed tomographic angiography and fractional flow reserve

    DEFF Research Database (Denmark)

    Kristensen, Thomas Skaarup; Engstrøm, Thomas; Kelbæk, Henning

    2010-01-01

    Coronary CT angiography (CCTA) has become an important modality to evaluate the presence of coronary artery disease. Coronary artery stenosis of intermediate severity remains a therapeutic dilemma. Measurement of fractional flow reserve (FFR) during coronary angiography is the most established...

  4. First experience of combined cardiac PET/64-detector CT angiography with invasive angiographic validation

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Endozo, Raymondo; Menezes, Leon J.; Prvulovich, Elizabeth; Ell, Peter J.; Speechly-Dick, Marie-Elsya; McEwan, Jean; Pugliese, Francesca; Habib, Said B.

    2009-01-01

    Despite modern CT systems and expert evaluators, the diagnostic performance of coronary CT angiography is limited by overestimation of vessel stenosis which reduces the positive predictive value (PPV) of the test. The aim of this study was to evaluate the performance of combined cardiac PET/64-detector CT angiography. Included in this retrospective study were 33 consecutive patients (5 women, 28 men; mean age 61.6 years, range 47-87 years, mean BMI 27.3±5.2 kg/m 2 ) with clinically suspected flow-limiting coronary artery disease who underwent combined cardiac PET/64-detector CT angiography and invasive angiography. Combined PET/CT images were reported by an experienced dual-accredited radiologist/nuclear physician. An experienced cardiac CT radiologist re-read the CT images without PET. Stenotic disease was defined as >50% vessel narrowing. Invasive coronary angiography was used as a reference standard. Local ethics committee approval and patient consent were obtained. CT angiography (without PET data) was concordant with invasive angiography in 31/33 patients and at a patient level, the sensitivity in detecting significant coronary artery lesions was 100%, the specificity was 82%, the PPV was 92% and the negative predictive value (NPV) was 100%. Using combined PET/CT angiography the findings were concordant with invasive angiography in 32/33 patients and at a patient level, the sensitivity was 96%, the specificity was 100%, the PPV was 100% and the NPV was 91%. The use of integrated cardiac PET/64-detector CT angiography is feasible and appears to improve some aspects of the diagnostic performance of 64-detector coronary artery angiography in detecting coronary artery disease. (orig.)

  5. Spontaneous rectus sheath hematoma: The utility of CT angiography

    Directory of Open Access Journals (Sweden)

    Antonio Pierro, MD

    2018-04-01

    Full Text Available We described the utility of computed tomography (CT angiography in detection of bleeding vessels for a rapid percutaneous arterial embolization of the spontaneous rectus sheath hematoma. A 70-year-old woman comes to our attention with acute abdominal pain and a low hemoglobin level. An unenhanced CT was performed demonstrating a large rectus sheath hematoma. A conservative management was initially established. Despite this therapy, the abdominal pain increased together with a further decrease of hemoglobin values. A CT angiography was then performed, demonstrating an active bleeding within the hematoma and addressing the patient to a rapid percutaneous arterial embolization. Keywords: Rectus sheath hematoma, Acute abdomen, Arterial embolization, CT angiography, Active bleeding

  6. Nosocomial septicemia and therapeutic angiography. Report of four cases

    International Nuclear Information System (INIS)

    Meyer, Ph.; Reizine, D.; Merland, J.J.; Guerin, J.M.

    1988-01-01

    Therapeutic angiography may be responsible for rare, but serious infectious complications.The authors report 4 cases occurring immediately following angiography. Three modes of contamination are proposed. Contamination by material used during the angiography is due to multiresistant hospital organisms. Penetration of cutaneous organisms into the circulation from the puncture site and bacterial contamination of a focus of tissue necrosis distal to the embolisation explain the other cases. Curative treatment is difficult because of the possibility of contamination of the embolisation material. Prophylactic treatment is essential and consists of respect of the rules of surgical asepsis, bacteriological control of the fluids used and eradication of adjacent septic foci. Routine antibiotic prophylaxis has yet to be evaluated [fr

  7. Evaluation of angiography performed by radiographers and nurses

    International Nuclear Information System (INIS)

    Chalmers, N.; Conway, B.; Andrew, H.; Parkinson, A.; Butterfield, J.S.; Fawcitt, R. A.

    2002-01-01

    AIM: To evaluate out-patient angiography performed by nurses and radiographers. MATERIALS AND METHODS: A protocol for out-patient angiography performed by nurses and radiographers was drawn up and approved by the Trust's Risk Management Committee. Following training, two experienced radiographers and one nurse undertook elective peripheral or renal angiography according to the protocol on 187 patients. Angiograms were performed using a 3F catheter introduced into the abdominal aorta from a femoral approach. Patients were discharged after 2 hours and contacted by telephone the following morning. RESULTS: No patient refused consent for the procedure. One hundred and seventy-two patients underwent successful catheterization without assistance from a radiologist. Radiologist assistance was required with femoral puncture or catheter/guidewire manipulation in 15 cases (8%). Images were considered diagnostic by the reporting radiologist in all but one case. This patient was recalled for further aortogram and pressure measurements. There was a single puncture site complication due to transient stenosis of the common femoral artery at the puncture site. This is thought to have been the result of subintimal injection of local anaesthetic, and it resolved spontaneously over 30 minutes. There were no delayed complications. CONCLUSION: Experienced nurses and radiographers can rapidly acquire the skills to perform diagnostic angiography safely and efficiently. Chalmers, N. et al. (2002)

  8. Digital subtraction angiography of the thoracic aorta

    International Nuclear Information System (INIS)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-01-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram

  9. Digital subtraction angiography of the thoracic aorta

    Energy Technology Data Exchange (ETDEWEB)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-02-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram.

  10. Clinical application of digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Morimoto, Tadashi; Kaku, Suiei; Morikawa, Eiji

    1984-01-01

    Intra-arterial digital subtraction angiography (IA-DSA) by the direct puncture of the carotid artery was described with special reference to its techniques, and cases were presented. This method was safe and painless and could be performed repeatedly. Cerebral angiographic images obtained by this method were either superior or fully compatible to the conventional cerebral angiography. It is therefore of great diagnostic value and can replace the conventional method. Furthermore, since the pretreatment is unnecessary and the time required is short, IA-DSA can be used as an adjuvant method for emergency diagnosis. (Namekawa, K)

  11. Application of longitudinal magnification effect to magnification stereoscopic angiography. A new method of cerebral angiography

    Energy Technology Data Exchange (ETDEWEB)

    Doi, K.; Rossmann, K.; Duda, E.E.

    1976-01-01

    A new method of stereoscopic cerebral angiography was developed which employs 2X radiographic magnification. In order to obtain the same depth perception in the object as with conventional contact stereoscopic angiography, one can make the x-ray exposures at two focal spot positions which are separated by only 1 inch, whereas the contact technique requires a separation of 4 inches. The smaller distance is possible because, with 2X magnification, the transverse detail in the object is magnified by a factor of two, but the longitudinal detail, which is related to the stereo effect, is magnified by a factor of four, due to the longitudinal magnification effect. The small focal spot separation results in advantages such as improved stereoscopic image detail, better image quality, and low radiation exposure to the patient.

  12. Application of longitudinal magnification effect to magnification stereoscopic angiography. A new method of cerebral angiography

    International Nuclear Information System (INIS)

    Doi, K.; Rossmann, K.; Duda, E.E.

    1976-01-01

    A new method of stereoscopic cerebral angiography was developed which employs 2X radiographic magnification. In order to obtain the same depth perception in the object as with conventional contact stereoscopic angiography, one can make the x-ray exposures at two focal spot positions which are separated by only 1 inch, whereas the contact technique requires a separation of 4 inches. The smaller distance is possible because, with 2X magnification, the transverse detail in the object is magnified by a factor of two, but the longitudinal detail, which is related to the stereo effect, is magnified by a factor of four, due to the longitudinal magnification effect. The small focal spot separation results in advantages such as improved stereoscopic image detail, better image quality, and low radiation exposure to the patient

  13. Early diagnosis of retinopathy in juvenile diabetes by fluorescence angiography

    International Nuclear Information System (INIS)

    Krzywicki, S.; Slankiewicz, A.; Jablonska-Budaj, U.

    1980-01-01

    The authors defined the usefulness of the fluorescein angiography of the retina and choroid in the early stage diagnosis of diabetic retinopathy in children comparing its results to the traditional ophthalmoscopy. Examination involved 50 children from 4 to 18 (30 boys and 20 girls) on insulin treatment. The duration of the disease was 1 to 14 years (average 7.36 years). Ophthalmoscopy showed pathological changes in 24% of the children. The fluorescein angiography visualized more microaneurysms compared to ophthalmoscopy and showed them sometimes in the eyes where they had not been found in eye fundus studies. By means of angiography the early and advanced stages of vascular complications were found in 64% of patients. Comparing to ophthalmoscopy a 40% increase was noted. Fluorescein angiography can lead to the decrease in the number of patients with markedly impaired visual acuity and cases of blindness in the diabetic population. (author)

  14. Early diagnosis of retinopathy in juvenile diabetes by fluorescence angiography

    Energy Technology Data Exchange (ETDEWEB)

    Krzywicki, S; Slankiewicz, A; Jablonska-Budaj, U [Szpital-Pomnik Centrum Zdrowia Dziecka, Warsaw (Poland). Zespol Problemowy Okulistiky

    1980-09-01

    The authors defined the usefulness of the fluorescein angiography of the retina and choroid in the early stage diagnosis of diabetic retinopathy in children comparing its results to the traditional ophthalmoscopy. Examination involved 50 children from 4 to 18 (30 boys and 20 girls) on insulin treatment. The duration of the disease was 1 to 14 years (average 7.36 years). Ophthalmoscopy showed pathological changes in 24% of the children. The fluorescein angiography visualized more microaneurysms compared to ophthalmoscopy and showed them sometimes in the eyes where they had not been found in eye fundus studies. By means of angiography the early and advanced stages of vascular complications were found in 64% of patients. Comparing to ophthalmoscopy a 40% increase was noted. Fluorescein angiography can lead to the decrease in the number of patients with markedly impaired visual acuity and cases of blindness in the diabetic population.

  15. Normal variants of the intracranial circulation demonstrated by MR angiography at 3 T

    International Nuclear Information System (INIS)

    Parmar, H.; Sitoh, Y.Y.; Hui, F.

    2005-01-01

    Magnetic resonance angiography (MRA) at 3 T offers increased signal to noise ratio with better background suppression, leading to exquisite depiction of the intracranial circulation. We present a pictorial review of the normal variations and anomalies of the intracranial circulation detected on MRA performed on a high field 3 T clinical scanner using parallel imaging techniques. The salient imaging features of these anomalies and normal variations are discussed with relevance to clinical practice

  16. Delayed angiography in the investigation of intracerebral hematomas caused by small arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Willinsky, R.A. (Dept. of Radiology, Toronto Hospital, Western Div., Toronto, ON (Canada) Univ. of Toronto, Brain Vascular Malformation Study Group, ON (Canada)); Fitzgerald, M. (Dept. of Radiology, Toronto Hospital, Western Div., Toronto, ON (Canada)); TerBrugge, K. (Dept. of Radiology, Toronto Hospital, Western Div., Toronto, ON (Canada) Univ. of Toronto, Brain Vascular Malformation Study Group, ON (Canada)); Montanera, W. (Dept. of Radiology, Toronto Hospital, Western Div., Toronto, ON (Canada)); Wallace, M. (Div. of Neurosurgery, Dept. of Surgery, Toronto Hospital, Western Div., ON (Canada) Univ. of Toronto, Brain Vascular Malformation Study Group, ON (Canada))

    1993-04-01

    We reviewed the clinical and radiological features of ten patients with small arteriovenous malformations that caused intracerebral hematomas. In six patients, angiography showed a small nidus (less than 1 cm in diameter) with a shunt at the site of the hematoma, and in four only an early-filling vein was evident. Six patients had only delayed angiography (4 weeks or more after the ictus). In three, angiography within 2 days of the ictus failed to reveal the cause of the bleed, but repeat angiography showed an early-filling vein in two, and a nidus with shunting in one. In only one patient did early angiography reveal the malformation. MRI was obtained in eight patients, and in two prominent vessels were evident in the wall of the hematoma cavity. In investigation of an unexplained intracerebral hematoma, MRI may be useful to exclude a neoplasm or cavernoma, although the latter may be not be evident in the presence of a recent hematoma. We suggest early MRI and angiography for investigation of an unexplained, nonhypertensive intracerebral bleed, with follow-up MRI and dealyed angiography if the initial studies fail to reveal the cause. (orig.)

  17. Variations of the posterior cerebral artery diagnosed by MR angiography at 3 tesla

    Energy Technology Data Exchange (ETDEWEB)

    Uchino, Akira; Saito, Naoko; Takahashi, Masahiro; Okano, Nanami; Tanisaka, Megumi [Saitama Medical University International Medical Center, Department of Diagnostic Radiology, Hidaka, Saitama (Japan)

    2016-02-15

    Fenestration, early bifurcation, and duplication of the posterior cerebral artery (PCA) and the so-called hyperplastic anterior choroidal artery (AChA), considered a variation of the PCA, are rare. We evaluated the prevalence and characteristic features of these PCA variations on magnetic resonance (MR) angiography. We reviewed intracranial MR angiographic images of 2402 patients examined using a 3-tesla scanner. Images from the skull base to the intracranial region were obtained using the standard time-of-flight technique. We excluded images of 52 patients with insufficient image quality or occlusion of the PCA(s) and retrospectively evaluated the images of 2350 patients using a picture archiving and communication system. We observed PCA fenestration in eight (0.34 %) patients, most at the P1 segment and P1-P2 junction and all small in size, early bifurcation at the P1-P2 junction or proximal P2A segment in eight (0.34 %) patients, complete duplication in one patient, and hyperplastic AChA in 13 (0.55 %) patients. Eleven of the 13 hyperplastic AChAs supplied only the territory of the temporal branch of the PCA, and the remaining two supplied the entire territory of the PCA. We observed PCA variations in 30 (1.28 %) patients. We believe the name ''hyperplastic AChA'' inaccurately describes variations of the PCA in which the AChA supplies part of or all of the territory of the PCA and propose ''accessory PCA'' to describe an AChA that supplies part of the territory of the PCA or ''replaced PCA'' to describe that vessel that supplies the territory all branches of the PCA. (orig.)

  18. Digital subtraction angiography in pediatric cerebrovascular occlusive disease

    International Nuclear Information System (INIS)

    Faerber, E.N.; Griska, L.A.B.; Swartz, J.D.; Capitanio, M.A.; Popky, G.L.

    1984-01-01

    While conventional angiography has been used to demonstrate cerebrovascular occlusive disease in the past, digital subtraction angiography (DSA) is capable of showing progressive vascular involvement with ease, simplicity, and extremely low morbidity, making it particularly well suited for children and outpatients either alone or coordinated with computed tomography. The authors discuss the usefulness and advantages of DSA as demonstrated in 7 infants and children with hemiplegia, 4 of whom had sickle-cell disease

  19. Contrast settling in cerebral aneurysm angiography

    International Nuclear Information System (INIS)

    Wang Zhijie; Hoffmann, Kenneth R; Guterman, Lee R; Wang Zhou; Rudin, Stephen; Meng Hui

    2005-01-01

    During angiography, blood flow is visualized with a radiopaque contrast agent, which is denser than blood. In complex vasculature, such as cerebral saccular aneurysms, the density difference may produce an appreciable gravity effect, where the contrast material separates from blood and settles along the gravity direction. Although contrast settling has been occasionally reported before, the fluid mechanics behind it have not been explored. Furthermore, the severity of contrast settling in cerebral aneurysms varies significantly from case to case. Therefore, a better understanding of the physical principles behind this phenomenon is needed to evaluate contrast settling in clinical angiography. In this study, flow in two identical groups of sidewall aneurysm models with varying parent-vessel curvature was examined by angiography. Intravascular stents were deployed into one group of the models. To detect contrast settling, we used lateral view angiography. Time-intensity curves were analysed from the angiographic data, and a computational fluid dynamic analysis was conducted. Results showed that contrast settling was strongly related to the local flow dynamics. We used the Froude number, a ratio of flow inertia to gravity force, to characterize the significance of gravity force. An aneurysm with a larger vessel curvature experienced higher flow, which resulted in a larger Froude number and, thus, less gravitational settling. Addition of a stent reduced the aneurysmal flow, thereby increasing the contrast settling. We found that contrast settling resulted in an elevated washout tail in the time-intensity curve. However, this signature is not unique to contrast settling. To determine whether contrast settling is present, a lateral view should be obtained in addition to the anteroposterior (AP) view routinely used clinically so as to rule out contrast settling and hence to enable a valid time-intensity curve analysis of blood flow in the aneurysm

  20. Hepatic Artery Angiography and Embolization for Hemobilia Following Laparoscopic Cholecystectomy

    International Nuclear Information System (INIS)

    Nicholson, Tony; Travis, Simon; Ettles, Duncan; Dyet, John; Sedman, Peter; Wedgewood, Kevin; Royston, Christopher

    1999-01-01

    Purpose: The effectiveness of angiography and embolization in diagnosis and treatment were assessed in a cohort of patients presenting with upper gastrointestinal hemorrhage secondary to hepatic artery pseudoaneurysm following laparoscopic cholecystectomy. Methods: Over a 6-year period 1513 laparoscopic cholecystectomies were carried out in our region. Nine of these patients (0.6%) developed significant upper gastrointestinal bleeding, 5-43 days after surgery. All underwent emergency celiac and selective right hepatic artery angiography. All were treated by coil embolization of the right hepatic artery proximal and distal to the bleeding point. Results: Pseudoaneurysms of the hepatic artery adjacent to cholecystectomy clips were demonstrated in all nine patients at selective right hepatic angiography. In three patients celiac axis angiography alone failed to demonstrate the pseudoaneurysm. Embolization controlled hemorrhage in all patients with no further bleeding and no further intervention. One patient developed a candidal liver abscess in the post-procedure period. All patients are alive and well at follow-up. Conclusion: Selective right hepatic angiography is vital in the diagnosis of upper gastrointestinal hemorrhage following laparoscopic cholecystectomy. Embolization offers the advantage of minimally invasive treatment in unstable patients, does not disrupt recent biliary reconstruction, allows distal as well as proximal control of the hepatic artery, and is an effective treatment for this potentially life-threatening complication

  1. Prediction of parent artery of anterior communicating artery aneurysm on CT angiography

    International Nuclear Information System (INIS)

    Chung, Jin Young; Han, Tae Il; Kim, Dae Hong; Han, Hyun Young; Kim, Hyun Jung; Song, Mun Kab

    1999-01-01

    To determine whether CT angiography can predict the parent artery of an anterior communicating aneurysm on the basis of characteristics of the aneurysm and precommunication anterior cerebral artery. Eighteen patients with anterior communication aneurysm were studied prospectively using CT angiography and conventional angiography. The parent artery of an aneurysm was predicted by evaluating aneurysm neck location, direction of aneurysm projection, and size of the precommunicating anterior cerebral artery, as seen on CT angiography. A somatom Plus-4 spiral CT scanner was used and shaded-surface display three-dimensional images were constructed. Aneurysm neck was located near the parent artery in 12 cases(66.7%), and aneurysm projection was against the parent artery in 11 cases(61.1%). The parent artery of the anterior cerebral artery was larger in 15 cases(83.3%), including ten cases of hypoplasia or agenesis of the contralateral anterior cerebral artery. In 17 of 18 aneurysms(94.4%) the parent artery seen on DSA was correctly predicted by CT angiography. The parent artery of an anterior communicating aneurysm can be predicted by evaluating aneurysm neck location, direction of aneurysm projection, and precommunicating anterior cerebral artery, as seen on CT angiography

  2. Evaluation of three-dimensional gadolinium-enhanced MR angiography using the timing monitoring function of contrast material (Smart Prep technique)

    International Nuclear Information System (INIS)

    Tsuchihashi, Toshio; Sasaki, Sadayuki; Yoshizawa, Satoshi; Maki, Toshio; Kitagawa, Matsuo; Suzuki, Takeshi

    1998-01-01

    The Smart Prep technique for gadolinium-enhanced three-dimensional MR angiography (3D-MRA) was evaluated in clinical practice. By monitoring signal intensity in the region of interest (tracking volume) in the target vessel, start timing after contrast injection can be optimized using the Smart Prep technique. Successful triggering was obtained in the chest, abdomen, and pelvic areas in about 80% of the cases in this study. Failures with this technique were mainly due to changes in tracking volume caused by patient motion and respiration. We noted that the scan started earlier than expected in the thoracic aorta when part of the heart or pulmonary artery was included in the tracking volume. Thus, care must be taken in defining the size and location of the tracking volume in gadolinium-enhanced 3D-MRA using the Smart Prep technique. (author)

  3. CAPILLARY NETWORK ANOMALIES IN BRANCH RETINAL VEIN OCCLUSION ON OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    Science.gov (United States)

    Rispoli, Marco; Savastano, Maria Cristina; Lumbroso, Bruno

    2015-11-01

    To analyze the foveal microvasculature features in eyes with branch retinal vein occlusion (BRVO) using optical coherence tomography angiography based on split spectrum amplitude decorrelation angiography technology. A total of 10 BRVO eyes (mean age 64.2 ± 8.02 range between 52 years and 76 years) were evaluated by optical coherence tomography angiography (XR-Avanti; Optovue). The macular angiography scan protocol covered a 3 mm × 3 mm area. The focus of angiography analysis were two retinal layers: superficial vascular network and deep vascular network. The following vascular morphological congestion parameters were assessed in the vein occlusion area in both the superficial and deep networks: foveal avascular zone enlargement, capillary non-perfusion occurrence, microvascular abnormalities appearance, and vascular congestion signs. Image analyses were performed by 2 masked observers and interobserver agreement of image analyses was 0.90 (κ = 0.225, P network of BRVO, a decrease in capillary density with foveal avascular zone enlargement, capillary non-perfusion occurrence, and microvascular abnormalities appearance was observed (P network showed the main vascular congestion at the boundary between healthy and nonperfused retina. Optical coherence tomography angiography in BRVO allows to detect foveal avascular zone enlargement, capillary nonperfusion, microvascular abnormalities, and vascular congestion signs both in the superficial and deep capillary network in all eyes. Optical coherence tomography angiography technology is a potential clinical tool for BRVO diagnosis and follow-up, providing stratigraphic vascular details that have not been previously observed by standard fluorescein angiography. The normal retinal vascular nets and areas of nonperfusion and congestion can be identified at various retinal levels. Optical coherence tomography angiography provides noninvasive images of the retinal capillaries and vascular networks.

  4. CT angiography of the renal arteries and veins: normal anatomy and variants.

    Science.gov (United States)

    Hazırolan, Tuncay; Öz, Meryem; Türkbey, Barış; Karaosmanoğlu, Ali Devrim; Oğuz, Berna Sayan; Canyiğit, Murat

    2011-03-01

    Conventional angiography has long been regarded as gold standard imaging modality for evaluation of the renal vasculature. Introduction of multidetector computed tomography (MDCT) angiography had a groundbreaking impact on evaluation of the renal vessels and is gradually replacing conventional angiography as standard imaging. Herein, we review and illustrate the normal and variant anatomy of renal vessels with special emphasis on imaging protocols and reconstruction techniques in MDCT.

  5. MR angiography of the pelvic and lower leg arteries: starting with time-resolved imaging of the lower leg is recommended

    International Nuclear Information System (INIS)

    Schmitt, R.; Christopoulos, G.; Brunner, S.; Froehner, S.; Dobritz, M.; Fellner, F.

    2001-01-01

    58 patients suffering from peripheral arterial vascular disease were examined using contrast-enhanced MR angiography with the intention of optimizing the visualization of lower leg arteries. Different from the customary acquisition order, were first the arteries of the lower legs depicted with three time-resolved phases. Afterwards, the iliacal and femoral vessels were imaged by applying the floating-table technique in two steps. In all cases, the lower leg arteries were depicted without overlying veins. By injecting the contrast agent in two phases, imaging quality of the iliofemoral arteries was not significantly reduced. - In conclusion, we would recommend the hybrid technique of peripheral contrast-enhanced MRA with primarily starting the acquisition of the lower legs in cases of foot infections or ulcerations where the transit time is reduced bi- or unilaterally. (orig.) [de

  6. Intraarterial digital subtraction angiography applied to diagnosis of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, Sadahiko; Sano, Akira; Imanaka, Kazufumi; Sasai, Keisuke; Nagae, Toshiyuki; Mizutani, Masaru; Hatabu, Hiroto; Sadatou, Norihiro; Kuroda, Yasumasa

    1985-12-01

    This paper deals with diagnostic values of intraarterial digital subtraction angiography (IADSA) for evaluating hepatocellular carcinoma. The present series consists of 44 patients with hepatocellular carcinoma, who underwent IADSA combined with conventional hepatic angiography 67 times in total. The evaluated vessels by IADSA included 70 hepatic arteries and 36 portal veins. Comparative studies on the image quality of IADSA with conventional angiography were made in referring to the tumor stain for arteriograms and resolution of intrahepatic portal branches for portograms. Diagnostic superiority including equality of DSA image to conventional was noted in arteriograms: 72.7 % in the right lobe and 86 % in the left. Most deteriorated DSA images were caused by misregistration artifacts. IADSA portography revealed basically diagnostic values to demonstrate lobar, segmental or more peripheral branches in about 95 % of cases studied. DSA, characterized by high contrast resolution and real-time subtraction, offered important and effective informations for interventional angiography as well as resectability of the tumors, requiring less contrast medium.

  7. Diagnosis of clinical staging of bladder cancer by CT and angiography

    International Nuclear Information System (INIS)

    Kobayashi, Isao; Igawa, Mikio; Ohnishi, Yoshio; Nakano, Hiroshi; Nihira, Hiromi; Mori, Masaki; Okada, Mitsuo.

    1984-01-01

    The preoperative staging of bladder cancer is of fundamental importance for prognostic evaluation and surgical indication. We studied the accuracy of computed tomography (CT) and angiography in defining the extent of local invasion in 16 patients with surgically proven carcinoma of the bladder. The overall accuracy of CT and angiographic staging in these cases was 75 % and 50 % respectively. In low stage, the accuracy was 90 % in CT and 70 % in angiography. In high stage, the accuracy was 50 % in CT and 16.7 % in angiography. Our results seems to indicate lower accuracy in high stage bladder cancer compared with other research. Data from a much larger series are required to ascertain whether the additional information provided by CT and angiography will produce any improvement in patient management. (author)

  8. The pattern of renal vessels in live related potential donors pool. A multislice computed tomography angiography review

    International Nuclear Information System (INIS)

    Mishra, A.; Ehtuish, Ehtuish F.

    2006-01-01

    To assess the renal vessel anatomy, compare the findings with the perioperative findings, to determine the sensitivity of multislice computed tomography (CT) angiography in the work-up of live potential donors and to discuss and compare the results of the present study with the reported results using single slice CT, magnetic resonance (MRI) and conventional angiography (CA).Retrospective analysis of the angiographic data of 118 of prospective live related kidney donors was carried out from October 2004 to August 2005 at the National Organ Transplant Centre, Tripoli Central Hospital, Libya. All donors underwent renal angiography on multislice (16-slice) CT scan using 80 cc intravenous contrast with 1.25 mm slice thickness followed by maximum intensity projection (MIP) and volume rendering techniques (VRT) post-processing algorithms. The number of vessels, vessel bifurcation, vessel morphology and venous anatomy were analyzed and the findings were compared with the surgical findings. Multislice spiral CT angiography (MSCTA) showed clear delineation of the main renal arteries in all donors with detailed vessel morphology. The study revealed 100% sensitivity in detection of accessory renal vessels, with an overall incidence of 26.7%, which is the most common distribution in the parahilar region. The present study showed 100% sensitivity in the visualization and detection of main and accessory renal vessels. These results were comparable with conventional angiography which has so far been considered as the gold standard and were found superior in specificity and accuracy to the use of single slice CT (SSCT) and MR in the angiographic work-up of live renal donors. Due to improved detection of accessory vessels less than 2 mm in diameter, a higher incidence of aberrant vessels was seen on the right side as has been suggested so far. (author)

  9. The emerging role of multidetector row CT angiography in the diagnosis of cervical arterial dissection: preliminary study

    International Nuclear Information System (INIS)

    Elijovich, Lucas; Kazmi, Khuram; Gauvrit, Jean Y.; Law, Meng

    2006-01-01

    Cervical artery dissection is an important cause of ischemic stroke, particularly in young patients. The diagnosis can be made with invasive catheter angiography or non-invasive imaging, either with MRI in conjunction with MR angiography (MRA) or CT angiography (CTA). Both modalities have been shown to have a high specificity and sensitivity. New developments such as multi-slice CTA (MSCTA) are emerging as an alternative methods for imaging the cervical and intracranial arteries. However, the contribution of modern MSCTA to carotid artery dissection has not been reported. We present a retrospective series of seven patients in whom both MSCTA and cervical axial T1 MRI and MRA were performed in the acute to subacute setting of internal carotid artery dissection. Carotid artery dissection was identified in all seven patients by MSCTA. The combination of MRI and MRA identified dissection in five of the seven patients. Additionally, a pseudoaneurysm was identified by MSCTA that was missed by MRI and MRA. Our findings confirm that MSCTA is a complementary technique in comparison to cervical axial T1 MRI and cervical MRA for diagnosing carotid artery dissection, and at times may provide additional information that can impact patient management. (orig.)

  10. Clinical application of electron beam computed tomography in intravenous three-dimensional coronary angiography

    International Nuclear Information System (INIS)

    Luo Chufan; Du Zhimin; Hu Chengheng; Li Yi; Zeng Wutao; Ma Hong; Li Xiangmin; Zhou Xuhui

    2002-01-01

    Objective: To investigate the clinical application of intravenous three-dimensional coronary angiography using electron beam computed tomography (EBCT) as compared with selective coronary angiography. Methods: Intravenous EBCT and selective coronary angiography were performed during the same period in 38 patients. The value of EBCT angiography for diagnosing coronary artery disease was evaluated. Results: The number of coronary arteries adequately evaluated by EBCT angiography was 134 out of 152 vessels (88.2%), including 100% of the left main coronary arteries, 94.7% of the left anterior descending arteries, 81.6% of the left circumflex arteries and 76.3 % of the right coronary arteries. Significantly more left main and heft anterior descending coronary arteries were adequately visualized than the left circumflex and right coronary arteries (P < 0.05). The sensitivity, specificity, accuracy, and positive and negative predictive value of EBCT angiography for diagnosing coronary artery disease were 88.0%, 84.6%, 86.8%, 91.7% and 78.6%, respectively. Of the 38 arteries with ≥ 50% stenosis, EBCT underestimated 8, for a sensitivity of 78.9%. Of the 96 arteries without significant stenosis, EBCT overestimated 7 stenosis, for a specificity of 92.7%. Conclusion: Intravenous electron beam computed tomographic coronary angiography is a promising noninvasive method for diagnosing coronary artery disease

  11. Evaluation of angiography performed by radiographers and nurses

    Energy Technology Data Exchange (ETDEWEB)

    Chalmers, N.; Conway, B.; Andrew, H.; Parkinson, A.; Butterfield, J.S.; Fawcitt, R. A

    2002-04-01

    AIM: To evaluate out-patient angiography performed by nurses and radiographers. MATERIALS AND METHODS: A protocol for out-patient angiography performed by nurses and radiographers was drawn up and approved by the Trust's Risk Management Committee. Following training, two experienced radiographers and one nurse undertook elective peripheral or renal angiography according to the protocol on 187 patients. Angiograms were performed using a 3F catheter introduced into the abdominal aorta from a femoral approach. Patients were discharged after 2 hours and contacted by telephone the following morning. RESULTS: No patient refused consent for the procedure. One hundred and seventy-two patients underwent successful catheterization without assistance from a radiologist. Radiologist assistance was required with femoral puncture or catheter/guidewire manipulation in 15 cases (8%). Images were considered diagnostic by the reporting radiologist in all but one case. This patient was recalled for further aortogram and pressure measurements. There was a single puncture site complication due to transient stenosis of the common femoral artery at the puncture site. This is thought to have been the result of subintimal injection of local anaesthetic, and it resolved spontaneously over 30 minutes. There were no delayed complications. CONCLUSION: Experienced nurses and radiographers can rapidly acquire the skills to perform diagnostic angiography safely and efficiently. Chalmers, N. et al. (2002)

  12. Interventional and intravascular MR angiography

    International Nuclear Information System (INIS)

    Ladd, M.E.; Debatin, J.F.

    2000-01-01

    Magnetic resonance imaging (MRI) has a number of characteristics which make it attractive for guidance of intravascular therapeutic procedures, including high soft tissue contrast, imaging in any arbitrary oblique plane, lack of ionizing radiation, and the ability to provide functional information, such as flow velocity and volume per unit time. For MR guidance of vascular interventions to be safe, catheters and guidewires must be visualized relative to the vascular system and surrounding tissues. A number of approaches for making instruments visible in an MR environment are presented, including both passive and active techniques. Passive techniques depend on contrast agents or susceptibility artifacts, whereas active techniques, including MR tracking, MR profiling, and active field inhomogeneity, use some form of electrical coil built into the instrument. The potential for obtaining high-resolution images of the vessel wall using coils built into a catheter is also discussed. These images provide the capability to distinguish and identify various plaque components. The additional capabilities of MRI could potentially open up new applications beyond those currently performed under X-ray fluoroscopic guidance. (orig.) [de

  13. Vascular imaging with spiral CT. The way to CY angiography

    International Nuclear Information System (INIS)

    Prokop, M.; Schaefer, C.; Kalender, W.A.; Polacin, A.; Galanski, M.

    1993-01-01

    Spiral CT is a technique that allows for high-quality two-dimensional angiographic projections and 3D imaging of vascular structures. The authors present the technical and methodological principles of the technique, including scan parameters and parameters of contrast application for various clinical imaging tasks. They present their experience with over 150 clinical cases using spiral CT angiography. Suitable applications of this technique include cogenital anomalies, aneurysms, dissections, stenoses, thrombi and vascular tumor involvement. Given a problem-adapted examination technique, pathologic changes in vessels of as little as 2 mm can be visualized. In some cases with complex vascular anatomy, spiral CT angiography can be superior to arterial angiography. (orig.) [de

  14. Clinical Assessment of a New Stereoscopic Digital Angiography System

    International Nuclear Information System (INIS)

    Moll, Thierry; Douek, Philippe; Finet, Gerard; Turjman, Francis; Picard, Catherine; Revel, Didier; Amiel, Michel

    1998-01-01

    Purpose: To assess the clinical feasibility of an experimental modified angiographic system capable of real-time digital stereofluoroscopy and stereography in X-ray angiography, using a twin-focus tube and a stereoscopic monitor. Methods: We report the experience obtained in 37 patients with a well-documented examination. The patients were examined for coronary angiography (11 cases), aortography (7 cases), pulmonary angiography (6 cases), inferior vena cava filter placement (2 cases), and cerebral angiography (11 cases). Six radiologists were asked to use stereoscopic features for fluoroscopy and angiography. A questionnaire was designed to record their subjective evaluation of stereoscopic image quality, ergonomics of the system, and its medical interest. Results: Stereofluoroscopy was successfully used in 25 of 37 cases; diplopia and/or ghost images were reported in 6 cases. It was helpful for aortic catheterization in 10 cases and for selective catheterization in 5 cases. In stereoangiography, depth was easily and accurately perceived in 27 of 37 cases; diplopia and/or ghost images were reported in 4 cases. A certain gain in the three-dimensional evaluation of the anatomy and relation between vessels and lesions was noted. As regards ergonomic considerations, polarized spectacles were not considered cumbersome. Visual fatigue and additional work were variously reported. Stereoshift tuning before X-ray acquisition was not judged to be a limiting factor. Conclusion: A twin-focus X-ray tube and a polarized shutter for stereoscopic display allowed effective real-time three-dimensional perception of angiographic images. Our clinical study suggests no clear medical interest for diagnostic examinations, but the field of interventional radiology needs to be investigated

  15. Diagnosing coronary artery disease after a positive coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Nissen, L; Winther, S; Westra, J

    2018-01-01

    Aims: Perfusion scans after coronary computed tomography angiography (CCTA) in patients with suspected coronary artery disease (CAD) may reduce unnecessary invasive coronary angiographies (ICAs). However, the diagnostic accuracy of perfusion scans after primary CCTA is unknown. The aim...

  16. Optical coherence tomography angiography in age-related macular degeneration: The game changer.

    Science.gov (United States)

    Lupidi, Marco; Cerquaglia, Alessio; Chhablani, Jay; Fiore, Tito; Singh, Sumit Randhir; Cardillo Piccolino, Felice; Corbucci, Roberta; Coscas, Florence; Coscas, Gabriel; Cagini, Carlo

    2018-04-01

    Optical coherence tomography angiography is one of the biggest advances in ophthalmic imaging. It enables a depth-resolved assessment of the retinal and choroidal blood flow, far exceeding the levels of detail commonly obtained with dye angiographies. One of the first applications of optical coherence tomography angiography was in detecting the presence of choroidal neovascularization in age-related macular degeneration and establishing its position in relation to the retinal pigmented epithelium and Bruch's membrane, and thereby classifying the CNV as type 1, type 2, type 3, or mixed lesions. Optical coherence tomography angiograms, due to the longer wavelength used by optical coherence tomography, showed a more distinct choroidal neovascularization vascular pattern than fluorescein angiography, since there is less suffering from light scattering or is less obscured by overlying subretinal hemorrhages or exudation. Qualitative and quantitative assessments of optical coherence tomography angiography findings in exudative and nonexudative age-related macular degeneration have been largely investigated within the past 3 years both in clinical and experimental settings. This review constitutes an up-to-date of all the potential applications of optical coherence tomography angiography in age-related macular degeneration in order to better understand how to translate its theoretical usefulness into the current clinical practice.

  17. Multislice computed tomographic coronary angiography: experience in a UK centre

    International Nuclear Information System (INIS)

    Morgan-Hughes, G.J.; Marshall, A.J.; Roobottom, C.A.

    2003-01-01

    AIM: To evaluate the technique of coronary angiography with retrospectively electrocardiogram (ECG)-gated four-slice helical computed tomography (CT). MATERIALS AND METHODS: Within 1 month of undergoing routine day-case diagnostic coronary angiography, 30 consecutive patients also underwent retrospectively ECG-gated multislice CT coronary angiography. This enabled direct comparison of seven segments of proximal and mid-coronary artery for each patient by two blinded assessors. Each segment of coronary artery from the multislice CT image was evaluated initially for 'assessability' and those segments deemed assessable were subsequently investigated for the presence or absence of a significantly (n=70%) stenotic lesion. RESULTS: Overall 68% of proximal and mid-coronary artery segments were assessable. The sensitivity and specificity of four-slice CT coronary angiography in assessable segments for detecting the presence or absence (n=70%) of stenoses were 72 and 86%, respectively. These results correspond to a positive predictive value of 53% and a 93% negative predictive value. If the 32% of non-assessable segments are added into the calculation then the sensitivity and specificity fall to 49 and 66%, respectively. CONCLUSION: Although multislice CT coronary angiography is a promising technique, the overall assessability and diagnostic accuracy of four-slice CT acquisition is not sufficient to justify routine clinical use. Further, evaluation should investigate the benefit of the reduction in temporal and spatial resolution offered by 16 and 32 slice acquisition

  18. The clinical value of three-dimensional contrast-enhanced MR angiography in abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Liu Qi; Lu Jianping; Tian Jianming; Wang Fei; Wang Li; Jin Aiguo; Zeng Hao; Gong Jianguo

    2004-01-01

    Objective: To evaluate the clinical value of three-dimensional contrast-enhanced MR angiography (3D CE-MRA) and its 3D reconstruction in the diagnosis of abdominal aortic aneurysms (AAA). Methods: Sixty-three patients with clinically diagnosed AAA underwent 3D CE-MRA combined with other sequences. 3D CE-MRA was performed with a 3D FISP sequence(TR, TE, FA=3.64 ms, 1.44 ms, 25 degrees, matrix=196 x 512, eff. slice=1.8 mm, FOV 30 cm x 40 cm, acquisition time=18-20 s) after injection of 0.2 mmol Gd-DTPA per kg b. w. A bolus-test was done before angiography to optimize imaging delay time. After 3D CE-MRA a T 1 -weighted sequence was acquired on the axial plane. The source images were subtracted from mask images and transferred to computer workstation, and subsequently post-processed using 3D reconstruction. All sequences were used to depict the type, location, extent, and thrombosis of the AAA, the morphology of its proximal neck, the distal aortoiliac inflow tract, and the relationship with the branches of aorta. The length, diameter, and angle of the aneurysm sac, and proximal and distal arteries were measured. The clinical role was evaluated for treatment planning. Results: High-quality 3D CE-MRA/MRI images were obtained in all patients. Among them, fifty-six had infrarenal AAA, five juxtarenal AAA, and two AAA with suprarenal extension. The mean diameter of aneurysms was 5.3 cm. The thrombosis was thicker than 2.0 cm in 26 patients. 3D CE-MRA clearly demonstrated the morphology and extent of AAA, and its proximal neck and distal aortoiliac inflow tract. The accurate parameters needed by endovascular treatment were gained simultaneously. Aneurysm and its neck depiction at 3D CE-MRA was better than that at DSA. The endovascular and surgical treatment were selected according the images (31 endovascular treatment, 4 surgical treatment, 28 conservative treatment only). The parameters at 3D CE-MRA coincided well with those at DSA in all cases (P>0.1). Conclusion: 3D CE

  19. Digital subtraction angiography in patients with central vertigo

    International Nuclear Information System (INIS)

    Inamori, Toru; Takayasu, Yukio; Umetani, Yoshio; Taruoka, Akinori.

    1985-01-01

    Digital subtraction angiography (DSA) is a recently developed non-invasive intravenous angiography which has become possible through real time digital subtraction of x-ray transmission data from an image intensifier and television system. The output signals of the image intensifier-television camera system are digitized by an analog-digital converter. The digital information, 512x512 pixels and 9 bits deep, is fed into the image processing assembly after logarithmic amplification, where 2-8 frames are added and subtracted from mask images for the final digital images. Intravenous digital subtraction angiography was performed in 21 patients with intractable dizzy spells of central origin resistant to treatment. These patients showed some signs of CNS disturbance, although there were no significant findings on CT scans. Surprisingly, findings were abnormal in 14 of 21 patients (66.7%). DSA is, therefore, considered to be an important aid in the diagnosis of vertigo of the central type. (J.P.N.)

  20. Evaluation of fast highly undersampled contrast-enhanced MR angiography (sparse CE-MRA) in intracranial applications - initial study

    International Nuclear Information System (INIS)

    Gratz, Marcel; Quick, Harald H.; Schlamann, Marc; Goericke, Sophia; Maderwald, Stefan

    2017-01-01

    To assess the image quality of sparsely sampled contrast-enhanced MR angiography (sparse CE-MRA) providing high spatial resolution and whole-head coverage. Twenty-three patients scheduled for contrast-enhanced MR imaging of the head, (N = 19 with intracranial pathologies, N = 9 with vascular diseases), were included. Sparse CE-MRA at 3 Tesla was conducted using a single dose of contrast agent. Two neuroradiologists independently evaluated the data regarding vascular visibility and diagnostic value of overall 24 parameters and vascular segments on a 5-point ordinary scale (5 = very good, 1 = insufficient vascular visibility). Contrast bolus timing and the resulting arterio-venous overlap was also evaluated. Where available (N = 9), sparse CE-MRA was compared to intracranial Time-of-Flight MRA. The overall rating across all patients for sparse CE-MRA was 3.50 ± 1.07. Direct influence of the contrast bolus timing on the resulting image quality was observed. Overall mean vascular visibility and image quality across different features was rated good to intermediate (3.56 ± 0.95). The average performance of intracranial Time-of-Flight was rated 3.84 ± 0.87 across all patients and 3.54 ± 0.62 across all features. Sparse CE-MRA provides high-quality 3D MRA with high spatial resolution and whole-head coverage within short acquisition time. Accurate contrast bolus timing is mandatory. (orig.)

  1. Evaluation of fast highly undersampled contrast-enhanced MR angiography (sparse CE-MRA) in intracranial applications - initial study

    Energy Technology Data Exchange (ETDEWEB)

    Gratz, Marcel; Quick, Harald H. [University of Duisburg-Essen, Erwin L. Hahn Institute for MR Imaging, Essen (Germany); University Hospital Essen, High Field and Hybrid MR Imaging, Essen (Germany); Schlamann, Marc [University Hospital Giessen and Marburg GmbH, Neuroradiology, Giessen (Germany); University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Goericke, Sophia [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Maderwald, Stefan [University of Duisburg-Essen, Erwin L. Hahn Institute for MR Imaging, Essen (Germany)

    2017-03-15

    To assess the image quality of sparsely sampled contrast-enhanced MR angiography (sparse CE-MRA) providing high spatial resolution and whole-head coverage. Twenty-three patients scheduled for contrast-enhanced MR imaging of the head, (N = 19 with intracranial pathologies, N = 9 with vascular diseases), were included. Sparse CE-MRA at 3 Tesla was conducted using a single dose of contrast agent. Two neuroradiologists independently evaluated the data regarding vascular visibility and diagnostic value of overall 24 parameters and vascular segments on a 5-point ordinary scale (5 = very good, 1 = insufficient vascular visibility). Contrast bolus timing and the resulting arterio-venous overlap was also evaluated. Where available (N = 9), sparse CE-MRA was compared to intracranial Time-of-Flight MRA. The overall rating across all patients for sparse CE-MRA was 3.50 ± 1.07. Direct influence of the contrast bolus timing on the resulting image quality was observed. Overall mean vascular visibility and image quality across different features was rated good to intermediate (3.56 ± 0.95). The average performance of intracranial Time-of-Flight was rated 3.84 ± 0.87 across all patients and 3.54 ± 0.62 across all features. Sparse CE-MRA provides high-quality 3D MRA with high spatial resolution and whole-head coverage within short acquisition time. Accurate contrast bolus timing is mandatory. (orig.)

  2. Cost-effectiveness of identifying aortoiliac and femoropopliteal arterial disease with angiography or duplex scanning

    International Nuclear Information System (INIS)

    Coffi, S.B.; Ubbink, D.Th.; Dijkgraaf, M.G.W.; Reekers, J.A.; Legemate, D.A.

    2008-01-01

    Objectives: Cost-effectiveness analysis of three diagnostic imaging strategies for the assessment of aortoiliac and femoropopliteal arteries in patients with peripheral arterial occlusive disease. The strategies were: angiography as the reference strategy, duplex scanning (DS) plus supplementary angiography (S1) and DS plus confirmative angiography (S2). Design, materials and methods: A decision model was built with sensitivity and specificity data from literature, supplemented with prospective hospital cost data in Euro ( Euro ). The probability of correctly identifying the status of a lesion was taken as the primary outcome. We compared strategies by assessing the extra costs per additional correctly identified case. Results: Assuming no false positive or false negative results, angiography is the most effective strategy if the prevalence of significant obstructive lesions in the aortoiliac and femoropopliteal tract exceeds 70%, or if the sensitivity of duplex scanning is lower than 83%. In case of lower prevalence, strategy S1 becomes equally or even more effective than angiography. At a prevalence of 75%, performing angiography costs Euro 8443 per extra correctly identified case compared with strategy S1. Conclusions: In most situations angiography is more effective than diagnostic strategy S1. However, if society is unwilling to pay more than Euro 8443 for knowing a patient's disease status, diagnostic strategy S1 is a cost-effective alternative to angiography, especially at lower prevalence values

  3. Intravenous coronary angiography by electron beam computed tomography : a clinical evaluation

    NARCIS (Netherlands)

    Rensing, B J; Bongaerts, A; van Geuns, R J; van Ooijen, P; Oudkerk, M; de Feyter, P J

    1998-01-01

    BACKGROUND: -Noninvasive detection of coronary stenoses with electron beam CT (EBCT) after intravenous injection of contrast medium has recently emerged. We sought to determine the diagnostic accuracy of EBCT angiography in the clinical setting using conventional coronary angiography as the "gold

  4. Prognostic value of combined CT angiography and myocardial perfusion imaging versus invasive coronary angiography and nuclear stress perfusion imaging in the prediction of major adverse cardiovascular events

    DEFF Research Database (Denmark)

    Chen, Marcus Y.; Rochitte, Carlos E.; Arbab-Zadeh, Armin

    2017-01-01

    Purpose: To compare the prognostic importance (time to major adverse cardiovascular event [MACE]) of combined computed tomography (CT) angiography and CT myocardial stress perfusion imaging with that of combined invasive coronary angiography (ICA) and stress single photon emission CT myocardial p...

  5. Conventional renal angiography versus renal digital subtraction angiography (DSA) in the study of renovascular hypertension

    International Nuclear Information System (INIS)

    Essinger, A.; Morsier, B. de; Narbel, M.; Raimondi, S.

    1988-01-01

    A cost-benefit analysis comparing conventional renal angiography, IV and IA DSA and spot film cameras has been made in order to quantify the advantages and disadvantages of these techniques in screening for renal artery stenosis. DSA is the best modality of imaging, using very little films, easy to archive, with a spatial resolution inferior to conventional angiography but partially compensated by contrast resolution. The surface dose per image using a 512/512 matrix is two thirds less than a conventional film, giving thus an acceptable dose as long as technical personnel is well trained and thus the number of exposures is kept low. Spot film camera, due to its excellent spatial resolution, its low radiation dose and its low price, can also be used as a screening procedure but requires an arterial injection. DSA has furthermore the advantage of quantifying renal artery stenosis making future percutaneous transluminal angioplasty easier

  6. Optimization of three-dimensional time-of-flight magnetic resonance angiography of the intracranial arteries

    International Nuclear Information System (INIS)

    Harada, Kuniaki; Honmou, Osamu; Odawara, Yoshihiro; Bando, Michio; Houkin, Kiyohiro

    2006-01-01

    The signal-to-noise ratio obtained from arteries in three-dimensional (3D) time-of-flight (TOF) magnetic resonance (MR) angiography is often too low to allow clinical diagnosis because the radiofrequency pulse decreases the magnetization of protons in the blood and suppresses the in-flow effect in the slab. The present study adjusted the position of the head coil to boost arterial signal intensity. Ten healthy volunteers, eight men and two women aged 24-78 years, underwent 3D TOF MR angiography of the intracranial arteries with the same standard GE transmit-receive birdcage head coil using both normal and half position (lower edge of the coil level with the mouth) methods. Our subjects were divided into Group 1 consisted of five relatively young volunteers aged 24-42 years (mean 31.2 years), and Group 2 consisted of five older volunteers aged 70-78 years (mean 73 years). The following four arteries were chosen for analysis: the internal carotid artery (ICA), the proximal middle cerebral artery segment (M 1 ), and the two distal middle cerebral artery segments (M 2 , M 3 ). The half position method increased the signal-to-noise ratio in the ICA, M 1 , M 2 , and M 3 by 15%, 25%, 36%, and 44%, respectively. In general, this method resulted in the generation of stronger signals in the M 2 and M 3 in younger subjects and in all arteries examined in older subjects. The half position method can provide better MR angiograms in certain brain regions of younger people, and in all brain regions in older patients. (author)

  7. Diagnosis of arterial sequestration using multidetector CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Yu Hong, E-mail: yuhong.2002@hotmail.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China); Li Huimin, E-mail: lihuiminphd@163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China); Liu Shiyuan, E-mail: cjr.liushiyuan@vip.163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China); Xiao Xiangsheng, E-mail: cjr.xxsh@vip.163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China)

    2010-11-15

    Background: Arterial sequestration is a rare congenital disorder. The diagnostic evaluation of this condition using multidetector computerized tomography (MDCT) has not been described previously. The purpose of this study was to describe the characteristic features of this disorder and to assess the use of MDCT in visualizing the characteristic anatomic features. Methods: We retrospectively reviewed the records of seven patients with anomalous systemic blood supply to left lower lobe of the lung. All the patients had undergone MDCT angiography. To evaluate the lung parenchyma, bronchial branching pattern, and vascular anatomy, four series of images were systematically reconstructed as follows: contiguous transverse CT scans viewed at mediastinal and pulmonary window settings, oblique coronal and sagittal maximum intensity projections (MIP), multiplanar reconstruction (MPR), and three-dimensional volume-rendered images (VR) of airway and thoracic vascular structures. Results: All 7 cases had isolated and tortuous arterial anatomy from the descending thoracic aorta to the basal segment of the left lower lobe; however, variable distribution of branches was observed. Characteristic findings of anomalous systemic arterial (ASA) supply were distinct from those seen in other pulmonary sequestration syndromes and were well visualized by the use of noninvasive MDCT. Conclusion: Complex CT findings allow clear imaging of arterial sequestration and the ASA blood supply; MDCT angiography has demonstrated its value and accuracy in diagnosing this condition, obviating the use of digital subtraction angiography and magnetic resonance angiography for the diagnosis of arterial sequestration.

  8. Diagnosis of arterial sequestration using multidetector CT angiography

    International Nuclear Information System (INIS)

    Yu Hong; Li Huimin; Liu Shiyuan; Xiao Xiangsheng

    2010-01-01

    Background: Arterial sequestration is a rare congenital disorder. The diagnostic evaluation of this condition using multidetector computerized tomography (MDCT) has not been described previously. The purpose of this study was to describe the characteristic features of this disorder and to assess the use of MDCT in visualizing the characteristic anatomic features. Methods: We retrospectively reviewed the records of seven patients with anomalous systemic blood supply to left lower lobe of the lung. All the patients had undergone MDCT angiography. To evaluate the lung parenchyma, bronchial branching pattern, and vascular anatomy, four series of images were systematically reconstructed as follows: contiguous transverse CT scans viewed at mediastinal and pulmonary window settings, oblique coronal and sagittal maximum intensity projections (MIP), multiplanar reconstruction (MPR), and three-dimensional volume-rendered images (VR) of airway and thoracic vascular structures. Results: All 7 cases had isolated and tortuous arterial anatomy from the descending thoracic aorta to the basal segment of the left lower lobe; however, variable distribution of branches was observed. Characteristic findings of anomalous systemic arterial (ASA) supply were distinct from those seen in other pulmonary sequestration syndromes and were well visualized by the use of noninvasive MDCT. Conclusion: Complex CT findings allow clear imaging of arterial sequestration and the ASA blood supply; MDCT angiography has demonstrated its value and accuracy in diagnosing this condition, obviating the use of digital subtraction angiography and magnetic resonance angiography for the diagnosis of arterial sequestration.

  9. [Evaluation of diabetic microangiopathy using optical coherence tomography angiography].

    Science.gov (United States)

    Czakó, Cecília; Sándor, Gábor László; Ecsedy, Mónika; Szepessy, Zsuzsanna; Borbándy, Ágnes; Resch, Miklós; Papp, András; Récsán, Zsuzsa; Horváth, Hajnalka; Nagy, Zoltán Zsolt; Kovács, Illés

    2018-02-01

    Optical coherence tomography angiography is a non-invasive imaging technique that is able to visualize the different retinal vascular layers using motion contrast to detect blood flow without intravenous dye injection. This method might help to assess microangiopathy in diabetic retinopathy during screening and follow-up. To quantify retinal microvasculature alterations in both eyes of diabetic patients in relation to systemic risk factors using optical coherence tomography angiography. Both eyes of 36 diabetic patients and 45 individuals without diabetes were examined. Duration of diabetes, insulin therapy, blood pressure, HbA 1c , dyslipidemia, axial length and the presence of diabetic retinopathy were recorded. Retinal vessel density was measured by optical coherence tomography angiography. The effect of risk factors on vessel density and between-eye asymmetry was assessed using multivariable regression analysis. Vessel density was significantly lower and between-eye difference was significantly higher in diabetic patients compared to controls (pdiabetes duration (pdiabetic retinopathy compared to control subjects (pdiabetes compared to healthy subjects. By using optical coherence tomography angiography, the detection of these microvascular alterations is possible before clinically detectable diabetic retinopathy and might serve as a useful tool in both screening and timing of treatment. Orv Hetil. 2018; 159(8): 320-326.

  10. Neurologic complications of cerebral angiography in childhood moyamoya syndrome

    International Nuclear Information System (INIS)

    Robertson, R.L.; Chavali, R.V.; Robson, C.D.; Barnes, P.D.; Burrows, P.E.; Eldredge, E.A.; Scott, R.M.

    1998-01-01

    Purpose. To determine the incidence of neurologic complications of cerebral angiography in children with moyamoya syndrome (MMS) as compared to children without MMS. Materials and methods. One-hundred-ninety consecutive cerebral angiograms obtained in 152 children were evaluated. Sixty of these angiograms were obtained in 40 children with MMS. Patients underwent neurologic evaluation prior to and after the procedure. For this study, a neurologic complication was defined as any new focal neurologic deficit or alteration in mental status occurring during the procedure or within the ensuing 24 hours. Results. There were 2 neurologic complications within 24 hours of angiography, one in the MMS group and one in the non-MMS group. One patient with MMS became mute following angiography. The symptom resolved within 12 hours. One patient without MMS being examined postoperatively for residual arteriovenous malformation developed intracranial hemorrhage requiring reexploration 12 hours after the angiogram. Using a two-tail Fisher's exact test, there was no significant statistical difference in the ischemic (P = 0.3) or hemorrhagic (P = 1.0) complication rates between the group of patients with MMS and the non-MMS groups. Conclusion. The risk of a neurologic complication from cerebral angiography in children with MMS is low and not statistically different from the risk in children with other cerebrovascular disorders. (orig.)

  11. Clinical application of iopamidol (pamiray 300) for cerebral angiography

    International Nuclear Information System (INIS)

    Park, Sung Ho; Suh, Sang Hyun; Kim, Jin Na; Kim, Eung Yeop; Kim, Dong Joon; Lee, Seung Koo; Kim, Dong Ik

    2007-01-01

    The aim of this study was to assess the clinical safety and efficacy of Pamiray 300 (Iopamidol; Dongkook Pharm, Seoul, Korea) as a nonionic contrast medium for cerebral angiography. One hundred patients undergoing cerebral angiography were randomly assigned to receive Pamiray 300 after written consent had been obtained. Patients with adverse reactions were divided into two groups. One group consisted of patients with minor adverse events such as heat sensation and pain, and the other group consisted of patients with major adverse events such as dyspnea, laryngeal edema and shock. The qualities of the radiographic images were stratified into five grades by three independent radiologists. No abnormality induced by Pamiray 300 was seen by a physical and neurological examination, blood pressure measurement, electrocardiogram, respiration rate measurement and partial fraction of arterial oxygen recording. No major and severe adverse events occurred throughout the study. Patient sex, age, disease category, underlying disease and administered contrast dosage showed no statistical significance with regards to the occurrence of adverse events. The opacification of blood vessels in all patients was 'good' or 'excellent'. Based on the results of this study, Pamiray 300 is a safe, efficacious and well-tolerated contrast medium for use in cerebral angiography. Thus, Pamiray 300 can be used as a competitive medium in cerebral angiography

  12. Post-mortem CT-coronary angiography

    DEFF Research Database (Denmark)

    Pøhlsgaard, Camilla; Leth, Peter Mygind

    2007-01-01

    post-mortem coronary angiography and computerized tomography.  We describe how to prepare and inject the contrast medium, and how to establish a CT-protocol that optimizes spatial resolution, low contrast resolution and noise level. Testing of the method on 6 hearts, showed that the lumen...

  13. Comparison of digital subtraction angiography with gadolinium-enhanced magnetic resonance angiography in the diagnosis of renal artery stenosis

    International Nuclear Information System (INIS)

    Thornton, J.; O'Callaghan, J.; Varghese, J.C.; Lee, M.J.; Walshe, J.; O'Brien, E.

    1999-01-01

    Renal artery stenosis (RAS) is a treatable cause of hypertension and renal failure for which no ideal screening technique is currently available. We evaluated the use of dynamic gadolinium-enhanced magnetic resonance angiography (MRA) for the diagnosis of RAS. Sixty-two patients with secondary hypertension were enrolled in the study. All patients had conventional renal angiography and gadolinium enhanced MRA. The sequence used was a 3D FMP SPGR sequence with the following parameters (TR: 26 ms, TE: 6.9 ms, flip angle 40 , field of view 36 x 36 cm, matrix 246 x 256, 1 excitation). Gadolinium 0.3 mmol/kg was administered and 60 1.5-mm-thick partitions were obtained over a duration of 3.5 min. The MRA images were then compared with conventional digital subtraction angiography (DSA) images. Conventional DSA demonstrated 138 renal arteries, whereas gadolinium-enhanced MRA demonstrated 129 (93 %). Twenty-one renal artery stenoses and four occluded arteries were seen at conventional DSA. Gadolinium-enhanced MRA had a sensitivity of 88 %, specificity of 98 %, accuracy of 96 %, positive predictive value of 92 % and negative predictive value of 97 % when compared with conventional DSA. Gadolinium-enhanced MRA is an accurate technique for identifying patients with RAS. It is less sensitive in picking up accessory renal arteries. (orig.)

  14. Max CAPR: high-resolution 3D contrast-enhanced MR angiography with acquisition times under 5 seconds.

    Science.gov (United States)

    Haider, Clifton R; Borisch, Eric A; Glockner, James F; Mostardi, Petrice M; Rossman, Phillip J; Young, Phillip M; Riederer, Stephen J

    2010-10-01

    High temporal and spatial resolution is desired in imaging of vascular abnormalities having short arterial-to-venous transit times. Methods that exploit temporal correlation to reduce the observed frame time demonstrate temporal blurring, obfuscating bolus dynamics. Previously, a Cartesian acquisition with projection reconstruction-like (CAPR) sampling method has been demonstrated for three-dimensional contrast-enhanced angiographic imaging of the lower legs using two-dimensional sensitivity-encoding acceleration and partial Fourier acceleration, providing 1mm isotropic resolution of the calves, with 4.9-sec frame time and 17.6-sec temporal footprint. In this work, the CAPR acquisition is further undersampled to provide a net acceleration approaching 40 by eliminating all view sharing. The tradeoff of frame time and temporal footprint in view sharing is presented and characterized in phantom experiments. It is shown that the resultant 4.9-sec acquisition time, three-dimensional images sets have sufficient spatial and temporal resolution to clearly portray arterial and venous phases of contrast passage. It is further hypothesized that these short temporal footprint sequences provide diagnostic quality images. This is tested and shown in a series of nine contrast-enhanced MR angiography patient studies performed with the new method.

  15. MR imaging of the pulmonary vasculature - an update

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, Mark R.; Fisher, Mark T. [University of Iowa, Department of Radiology, Carver College of Medicine, Iowa City, Iowa (United States); Beek, Edwin J.R. van [University of Iowa, Department of Radiology, Carver College of Medicine, Iowa City, Iowa (United States); University of Iowa Hospitals and Clinics, JPP 3895, Department of Radiology, Iowa City, Iowa (United States)

    2006-06-15

    Although the advent of multi-detector row computed tomography (CT) angiography has been at the heart of improving the diagnostic management of pulmonary vascular disease, MR technology has also moved forward. This review outlines the current state of affairs of MR techniques for the assessment of pulmonary vascular diseases such as pulmonary hypertension, pulmonary arteritis and arteriovenous malformations. It highlights the main areas of MR angiography and MR perfusion imaging and discusses novel methods, such as non-contrast enhanced direct thrombus imaging, and will discuss its merits in the context of other diagnostic modalities. (orig.)

  16. First results of spiral CT angiography in the evaluation of carotid artery stenosis

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Brossmann, J.; Grabener, M.; Voss, C.; Heller, M.

    1995-01-01

    To determine the value of spiral CT angiography in Maximum Intensity Projection (MIP)-technique for evaluation of carotid artery stenosis. A comparison of the MIP technique with intraarterial DSA was done in 24 patients with 40 stenoses. Quantification of stenosis was determined according to the NASCET study: mild (0-29%), moderate (30-69%), severe (70-99%) and occlusion (100%). Totally the correlation of spiral CT angiography with DSA was 80% (r=0.93; p=0.0001). In the moderate stenosis group (r=1; p=0.1573), severe stenosis group (r=0.89; p=0.002) and the occlusion group (r=1; p=0.0009) there was a good correlation with DSA. In the mild stenosis group (r=0.55; p=0.0704) correlation of spiral CT angiography with DSA was poor. Spiral CT angiography allows an excellent delineation of calcifications. Tandem lesions and collateral flow cannot be shown with spiral CT angiography. (orig./MG) [de

  17. Multidetector CT angiography of renal vasculature: normal anatomy and variants

    Energy Technology Data Exchange (ETDEWEB)

    Tuerkvatan, Aysel; Oezdemir, Mustafa; Cumhur, Turhan; Oelcer, Tuelay [Tuerkiye Yueksek ihtisas Hospital, Department of Radiology, Sihhiye, Ankara (Turkey)

    2009-01-15

    Knowledge of the variations in renal vascular anatomy is important before laparoscopic donor or partial nephrectomy and vascular reconstruction for renal artery stenosis or abdominal aortic aneurysm. Recently, multidetector computed tomographic (MDCT) angiography has become a principal imaging investigation for assessment of the renal vasculature and has challenged the role of conventional angiography. It is an excellent imaging technique because it is a fast and non-invasive tool that provides highly accurate and detailed evaluation of normal renal vascular anatomy and variants. The number, size and course of the renal arteries and veins are easily identified by MDCT angiography. The purpose of this pictorial essay is to illustrate MDCT angiographic appearance of normal anatomy and common variants of the renal vasculature. (orig.)

  18. Multidetector CT angiography of renal vasculature: normal anatomy and variants

    International Nuclear Information System (INIS)

    Tuerkvatan, Aysel; Oezdemir, Mustafa; Cumhur, Turhan; Oelcer, Tuelay

    2009-01-01

    Knowledge of the variations in renal vascular anatomy is important before laparoscopic donor or partial nephrectomy and vascular reconstruction for renal artery stenosis or abdominal aortic aneurysm. Recently, multidetector computed tomographic (MDCT) angiography has become a principal imaging investigation for assessment of the renal vasculature and has challenged the role of conventional angiography. It is an excellent imaging technique because it is a fast and non-invasive tool that provides highly accurate and detailed evaluation of normal renal vascular anatomy and variants. The number, size and course of the renal arteries and veins are easily identified by MDCT angiography. The purpose of this pictorial essay is to illustrate MDCT angiographic appearance of normal anatomy and common variants of the renal vasculature. (orig.)

  19. Prevalence of fenestrated basilar artery with magnetic resonance angiography: a transversal study.

    Science.gov (United States)

    Arráez-Aybar, L A; Villar-Martin, A; Poyatos-Ruiperez, C; Rodriguez-Boto, G; Arrazola-Garcia, J

    2013-08-01

    Fenestration of the basilar artery (BA) is a rare anatomical variation in comparison to those of the other intracranial arteries constituting the cerebral arterial circle. The incidence is difficult to ascertain and data vary according to type of series and modalities of detection. Basilar artery fenestration (BAF) has been reported in association with arteriovenous malformations, vascular variants, other developmental anomalies and neurovascular conflicts as a consequence of relations between the arterial branches of the BA and the nerves and other structures in the posterior cranial fossa. However, the real clinical interest of BAF is due to the possible formation of an aneurysm at the junction of the fenestrated segment and less frequently to the thrombosis of the vessels. With the aim to establish the prevalence of BAF in our population, we made a transversal pilot study of the first 200 MR angiographies performed on patients attending for the first time to control their base pathology (vascular or not). We have described three patients with this condition (representing a prevalence of 1.5 % on MR angiography) to shed additional light on this anomaly, two cases located at 1/3 proximal end (type 1-BAF) and one case located at joint 1/3 medium-1/3 distal end, locating distal to the anterior inferior cerebellar artery (type 4-BAF). In neither case was any other lesion found (i.e. aneurysm, infarctions, ischemia or thromboembolism). The pertinent clinical anatomy and embryological basis for this variation are reviewed, and the possible clinical implications and associated findings are discussed.

  20. Time-resolved CT angiography in aortic dissection

    International Nuclear Information System (INIS)

    Meinel, Felix G.; Nikolaou, Konstantin; Weidenhagen, Rolf; Hellbach, Katharina; Helck, Andreas; Bamberg, Fabian; Reiser, Maximilian F.; Sommer, Wieland H.

    2012-01-01

    Objectives: We performed this study to assess feasibility and additional diagnostic value of time-resolved CT angiography of the entire aorta in patients with aortic dissection. Materials and methods: 14 consecutive patients with known or suspected aortic dissection (aged 60 ± 9 years) referred for aortic CT angiography were scanned on a dual-source CT scanner (Somatom Definition Flash; Siemens, Forchheim, Germany) using a shuttle mode for multiphasic image acquisition (range 48 cm, time resolution 6 s, 6 phases, 100 kV, 110 mAs/rot). Effective radiation doses were calculated from recorded dose length products. For all phases, CT densities were measured in the aortic lumen and renal parenchyma. From the multiphasic data, 3 phases corresponding to a triphasic standard CT protocol, served as a reference and were compared against findings from the time-resolved datasets. Results: Mean effective radiation dose was 27.7 ± 3.5 mSv. CT density of the true lumen peaked at 355 ± 53 HU. Compared to the simulated triphasic protocol, time-resolved CT angiography added diagnostic information regarding a number of important findings: the enhancement delay between true and false lumen (n = 14); the degree of membrane oscillation (n = 14); the perfusion delay in arteries originating from the false lumen (n = 9). Other additional information included true lumen collapse (n = 4), quantitative assessment of renal perfusion asymmetry (n = 2), and dynamic occlusion of aortic branches (n = 2). In 3/14 patients (21%), these additional findings of the multiphasic protocol altered patient management. Conclusions: Multiphasic, time-resolved CT angiography covering the entire aorta is feasible at a reasonable effective radiation dose and adds significant diagnostic information with therapeutic consequences in patients with aortic dissection.

  1. Detection and characterization of intracranial aneurysms: magnetic resonance angiography versus digital subtraction angiography

    International Nuclear Information System (INIS)

    Shahzad, R.; Younas, F.

    2011-01-01

    Objective: To compare magnetic resonance angiography (MRA) with Intra-arterial digital subtraction angiography (IA-DSA) in detection and characterization of intracranial aneurysms. Study Design: Comparative cross-sectional study. Place and Duration of Study: Department of Diagnostic Imaging, Lahore General Hospital, Lahore, from January to June 2007. Methodology: Thirty patients presented with aneurysmal subarachnoid haemorrhage (SAH) and focal neurological signs were selected by convenience sampling. Three dimensional time of flight (3D TOF) MRA using maximum intensity projection (MIP) was performed on all patients along with DSA. Results of 3D TOF MRA were compared with those of IA-DSA taking IA-DSA as Gold standard. Results: Out of 30 patients 14 (46.7%) were males and 16 (53.3%) were females with mean age of 41+-14.1 years. MRA detected 29 out of 30 aneurysmal lesions with sensitivity of 96.7%. Regarding characterization of aneurysms results of MRA were comparable to those of IA-DSA. Conclusion: 3D TOF MRA technique showed a high sensitivity in this study. This technique can be used as a non-invasive screening test for intracranial aneurysms and as a suitable alternative primary examination to IA-DSA prior to aneurysmal surgery. (author)

  2. Evaluation of renal vascular in living donors before transplantation using dynamic contrast enhanced MR angiography

    International Nuclear Information System (INIS)

    Wang Hong; Mu Xuetao; Zhong Xin; Dong Yuru; Dong Yue; Ma Yi; Wu Chunnan

    2010-01-01

    Objective: To explore whether dynamic contrast-enhanced MRA (DCE MRA) can provide an effective assessment of renal vascular in living donors before transplantation. Methods: Thirty five healthy living renal donor candidates were scanned on MR system before transplantation. After injection of Gd-DTPA 1 ml in vein, a test-bolus scan was used to get the time delay of Gd-DTPA reaching renal artery. Then, a 3D T 1 -weighted fast low-angle shot sequence (3D FLASH) was performed in the coronal plane. The 3D FLASH scan would repeat four times with an inter-phase of 10 seconds. Thus, the imaging of the renal arterial, venous and collecting systems were got. Two radiologists observed renal arteries and veins on original imaging and MIP reconstmcted imaging. The quality of MR angiography was evaluated on a five- point scale and the vascular anatomy or variations of the arterial and venous systems were recorded, using intraoperative findings as a standard of reference. Results: The quality for all MRA was good or very good for the most of living renal donors. Among 70 renals, several variations of vascular were found, including 5 left accessory artery, 9 right accessory artery, 3 left proximal arterial branch and 6 right proximal arterial branch. Among 70 renal veins, 1 right accessory veins and 2 left varicocele were observed. One small accessory artery of right kidney was missed with DCE MRA, but identified by operation. Conclusion: DCE MRA was noninvasive tool for evaluation of the renal vasculature and variations with high accuracy. It would be a good modality in preoperative evaluation of living renal donors. (authors)

  3. Intra-arterial Ultra-low-Dose CT Angiography of Lower Extremity in Diabetic Patients

    Energy Technology Data Exchange (ETDEWEB)

    Özgen, Ali, E-mail: draliozgen@hotmail.com [Yeditepe University Hospital, Department of Radiology (Turkey); Sanioğlu, Soner [Yeditepe University Hospital, Department of Cardiovascular Surgery (Turkey); Bingöl, Uğur Anıl [Yeditepe University Hospital, Department of Plastic Surgery (Turkey)

    2016-08-15

    PurposeTo image lower extremity arteries by CT angiography using a very low-dose intra-arterial contrast medium in patients with high risk of developing contrast-induced nephropathy (CIN).Materials and MethodsThree cases with long-standing diabetes mellitus and signs of lower extremity atherosclerotic disease were evaluated by CT angiography using 0.1 ml/kg of the body weight of contrast medium given via 10-cm-long 4F introducer by puncturing the CFA. Images were evaluated by an interventional radiologist and a cardiovascular surgeon. Density values of the lower extremity arteries were also calculated. Findings in two cases were compared with digital subtraction angiography images performed for percutaneous revascularization. Blood creatinine levels were followed for possible CIN.ResultsIntra-arterial CT angiography images were considered diagnostic in all patients and optimal in one patient. No patient developed CIN after intra-arterial CT angiography, while one patient developed CIN after percutaneous intervention.ConclusionIntra-arterial CT angiography of lower extremity might be performed in selected patients with high risk of developing CIN. Our limited experience suggests that as low as of 0.1 ml/kg of the body weight of contrast medium may result in adequate diagnostic imaging.

  4. Case Report of Bullous Pemphigoid following Fundus Fluorescein Angiography

    Directory of Open Access Journals (Sweden)

    Goktug Demirci

    2010-05-01

    Full Text Available Purpose: To report a first case of bullous pemphigoid (BP following intravenous fluorescein for fundus angiography. Clinical Features: A 70-year-old male patient was admitted to the intensive care unit with BP and sepsis. He reported a history of fundus fluorescein angiography with a pre-diagnosis of senile macular degeneration 2 months prior to presentation. At that time, fluorescein extravasated at the antecubital region. Following the procedure, pruritus and erythema began at the wrists bilaterally, and quickly spread to the entire body. The patient also reported a history of allergy to human albumin solution (Plamasteril®; Abbott 15 years before, during bypass surgery. On dermatologic examination, erythematous patches were present on the scalp, chest and anogenital region. Vesicles and bullous lesions were present on upper and lower extremities. On day 2 of hospitalization, tense bullae appeared on the upper and lower extremities. The patient was treated with oral methylprednisolone 48 mg (Prednol®; Mustafa Nevzat, topical clobetasol dipropionate 0.05% cream (Dermovate®; Glaxo SmithKline, and topical 4% urea lotion (Excipial Lipo®; Orva for presumptive bullous pemphigoid. Skin punch biopsy provided tissue for histopathology, direct immunofluorescence examination, and salt extraction, which were all consistent with BP. After 1 month, the patient was transferred to the intensive care unit with sepsis secondary to urinary tract infection; he died 2 weeks later from sepsis and cardiac failure. Conclusions: To our knowledge, this is the first reported case of BP following fundus fluorescein angiography in a patient with known human albumin solution allergy. Consideration should be made to avoid fluorescein angiography, change administration route, or premedicate with antihistamines in patients with known human albumin solution allergy. The association between fundus fluorescein angiography and BP should be further investigated.

  5. Radiological findings of dissecting aneurysm -a correlative study of CT with angiography-

    International Nuclear Information System (INIS)

    Bae, Tae Yeong; Park, Jae Hyung; Kim, Seung Hyup; Han, Man Chung

    1987-01-01

    This study comprised 16 patients with aortic dissecting aneurysm who were admitted to Seoul National University Hospital from May 1984 to January 1987. CT findings in 16 cases of aortic dissecting aneurysm were correlated with angiographic findings retrospectively. The results were analysed. 1. Number of male was 11 and that of female was 5. Male patients in fifties were most common and 4 in number. 13 patients had hypertension or history of hypertension among 14 patients. There were one case of Marfan's syndrome, preeclampsia and Takayasu's arteritis respectively. 2. There were 5 cases of DeBakey type I, 1 case of type II and 9 cases of types III dissecting aneurysm. Type III was most common. 3. CT confirmed as superior vena cava which was not identified whether it was superior vena cava or unopacified false lumen by angiography in one case. Regarding distal extent, authors defined A whose extent was proximal to diaphragm and B beyond it for convenience sake. There was one false negative case in CT among 16 cases which was diagnosed as dissecting aneurysm type IIIB by angiography and confirmed as type III surgically. One case was diagnosed as type IB by CT and as type IIIB by angiography and confirmed as type I surgically. Extent was more accurate in CT than angiography. One case was diagnosed as type II by CT but misdiagnosed as right atrial tumor by angiography. 4. Diagnostic sensitivities of CT and angiography in this study were 94% (15/16) respectively. CT was more advantageous in hemothorax, hemopericardium, hemomediastinum, unopacified false lumen, aortic wall calcification and getting information about mediastinum. In angiography aortic regurgitation and tear site and involvement of abdominal vessels could be observed

  6. Feasibility and utility of transradial cerebral angiography: experience during the learning period

    International Nuclear Information System (INIS)

    Kim, Ji Hyung; Park, Yong Sung; Chung, Chul Gu; Park, Kyeong Sug; Chung, Dong Jin; Kim, Hyun Jin

    2006-01-01

    We wanted to present our experiences for performing transradial cerebral angiography during the learning period, and we also wanted to demonstrate this procedure's technical feasibility and utility in various clinical situations. Thirty-two patients were enrolled in the study. All of them had unfavorable situations for performing transfemoral angiography, i.e., IV lines in the bilateral femoral vein, a phobia for groin puncture, decreased blood platelet counts, large hematoma or bruise, atherosclerosis in the bilateral femoral artery and the insistence of patients for choosing another procedure. After con firming the patency of the ulnar artery with a modified Allen's test and a pulse oximeter, the procedure was done using a 21-G micorpuncture set and 5-F Simon II catheters. After angiography, hemostasis was achieved with 1-2 minutes of manual compression and the subsequent application of a hospital-made wrist brace for two hours. The technical feasibility and procedure-related immediate and delayed complications were evaluated. The procedure was successful in 30/32 patients (93.8%). Failure occurred in two patients; one patient had hypoplasia of the radial artery and one patient had vasospasm following multiple puncture trials for the radial artery. Transradial cerebral angiography was technically feasible without significant difficulties even though it was tried during the learning period. Pain in the forearm or arm developed in some patients during the procedures, but this was usually mild and transient. Procedure-related immediate complications included severe bruising in one patient and a small hematoma in one patient. Any clinically significant complication or delayed complication such as radial artery occlusion was not demonstrated in our series. Transradial cerebral angiography is a useful alternative for the patients who have unfavorable clinical situations or contraindications for performing transfemoral cerebral angiography. For the experienced

  7. Radiological findings of dissecting aneurysm -a correlative study of CT with angiography-

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Tae Yeong; Park, Jae Hyung; Kim, Seung Hyup; Han, Man Chung [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1987-06-15

    This study comprised 16 patients with aortic dissecting aneurysm who were admitted to Seoul National University Hospital from May 1984 to January 1987. CT findings in 16 cases of aortic dissecting aneurysm were correlated with angiographic findings retrospectively. The results were analysed. 1. Number of male was 11 and that of female was 5. Male patients in fifties were most common and 4 in number. 13 patients had hypertension or history of hypertension among 14 patients. There were one case of Marfan's syndrome, preeclampsia and Takayasu's arteritis respectively. 2. There were 5 cases of DeBakey type I, 1 case of type II and 9 cases of types III dissecting aneurysm. Type III was most common. 3. CT confirmed as superior vena cava which was not identified whether it was superior vena cava or unopacified false lumen by angiography in one case. Regarding distal extent, authors defined A whose extent was proximal to diaphragm and B beyond it for convenience sake. There was one false negative case in CT among 16 cases which was diagnosed as dissecting aneurysm type IIIB by angiography and confirmed as type III surgically. One case was diagnosed as type IB by CT and as type IIIB by angiography and confirmed as type I surgically. Extent was more accurate in CT than angiography. One case was diagnosed as type II by CT but misdiagnosed as right atrial tumor by angiography. 4. Diagnostic sensitivities of CT and angiography in this study were 94% (15/16) respectively. CT was more advantageous in hemothorax, hemopericardium, hemomediastinum, unopacified false lumen, aortic wall calcification and getting information about mediastinum. In angiography aortic regurgitation and tear site and involvement of abdominal vessels could be observed.

  8. Feasibility and utility of transradial cerebral angiography: experience during the learning period

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Hyung; Park, Yong Sung; Chung, Chul Gu; Park, Kyeong Sug; Chung, Dong Jin; Kim, Hyun Jin [Konyang University Hospital, Daejeon (Korea, Republic of)

    2006-03-15

    We wanted to present our experiences for performing transradial cerebral angiography during the learning period, and we also wanted to demonstrate this procedure's technical feasibility and utility in various clinical situations. Thirty-two patients were enrolled in the study. All of them had unfavorable situations for performing transfemoral angiography, i.e., IV lines in the bilateral femoral vein, a phobia for groin puncture, decreased blood platelet counts, large hematoma or bruise, atherosclerosis in the bilateral femoral artery and the insistence of patients for choosing another procedure. After con firming the patency of the ulnar artery with a modified Allen's test and a pulse oximeter, the procedure was done using a 21-G micorpuncture set and 5-F Simon II catheters. After angiography, hemostasis was achieved with 1-2 minutes of manual compression and the subsequent application of a hospital-made wrist brace for two hours. The technical feasibility and procedure-related immediate and delayed complications were evaluated. The procedure was successful in 30/32 patients (93.8%). Failure occurred in two patients; one patient had hypoplasia of the radial artery and one patient had vasospasm following multiple puncture trials for the radial artery. Transradial cerebral angiography was technically feasible without significant difficulties even though it was tried during the learning period. Pain in the forearm or arm developed in some patients during the procedures, but this was usually mild and transient. Procedure-related immediate complications included severe bruising in one patient and a small hematoma in one patient. Any clinically significant complication or delayed complication such as radial artery occlusion was not demonstrated in our series. Transradial cerebral angiography is a useful alternative for the patients who have unfavorable clinical situations or contraindications for performing transfemoral cerebral angiography. For the experienced

  9. Comparative evaluation of 64-slice CT angiography and digital subtraction angiography in assessing the cervicocranial vasculature

    Directory of Open Access Journals (Sweden)

    Randolf Klingebiel

    2008-08-01

    Full Text Available Randolf Klingebiel1, Max Kentenich3, Hans-Christian Bauknecht3, Florian Masuhr2, Eberhard Siebert1, Markus Busch2, Georg Bohner11Department of Neuroradiology, 2Department of Neurology, 3Department of Radiology, Charité Universitary Medicine Berlin, GermanyBackground: Noninvasive 64-slice computed tomography angiography (64-MSCTA closely approximates conventional catheter angiography (DSA in terms of detail resolution. Objective: Retrospective evaluation of cervicocranial (cc 64-MSCTA in comparison with DSA in patients with presumptive cc vascular disorders.Material and methods: Twenty-four 64-MSCTA studies (32 mm detector width, slice thickness 0.5 mm, 120 kv, 150 mAs, pitch 0.75 of patients with presumptive cc vascular pathology (13 men, 11 women, mean age 38.3 ± 11.3 yrs, range 19–54 yrs were assessed in comparison with DSA studies without abnormal findings in age-matched patients (11 men, 13 women, mean age 39.7 ± 11.9 yrs, range 18–54 yrs. Study readings were performed in a blinded manner by two neuroradiologists with respect to image quality and assessibility of various cc vascular segments by using a five-point scale. Radiation exposure was calculated for 64-MSCTA.Results: Each reader assessed 384/528 different vessel segments (64-MSCTA/DSA. Superior image quality was attributed to DSA with respect to the C1 ICA–C6 ICA, A3 ACA, and P3 PCA segments as well the AICA and SCA. 64-MSCTA was scored superior for C7 ICA and V4 VA segments. A significantly increased number of nonassessable V2- and V3 VA segments in DSA studies was noted. The effective dose for 64-MSCTA amounted to 2.2 mSv.Conclusions: 64-MSCTA provides near-equivalent diagnostic information of the cc vasculature as compared with DSA. According to our results, DSA should be considered primarily when peripheral vessels (A3/P3 or ICA segments close to the skull base (C2-5 are of interest, such as in primary angiitis or stenoocclusive ICA disease, respectively.Keywords: CT-angiography

  10. Contrast-enhanced magnetic resonance angiography of persistent fifth aortic arch in children

    International Nuclear Information System (INIS)

    Zhong, Yumin; Zhu, Ming; Sun, Aimin; Li, Yuhua; Jaffe, Richard B.; Gao, Wei

    2007-01-01

    Cine angiography and echocardiography have been utilized to diagnose congenital aortic arch anomalies. However, the visualization of great vessels by echocardiography is limited, while cine angiography requires cardiac catheterization with ionizing radiation. Contrast-enhanced magnetic resonance angiography (MRA) is a noninvasive modality suitable for visualization of congenital aortic arch anomalies. To evaluate the utility of contrast-enhanced MRA in the diagnosis of persistent fifth aortic arch, a rare congenital aortic arch anomaly, and to compare the diagnostic accuracy of MRA with that of echocardiography and cine angiography. In four pediatric patients, contrast-enhanced MRA studies were performed for diagnosing persistent fifth aortic arch. The findings of MRA were compared with echocardiographic findings and confirmed by cine angiography and operation. Transthoracic surface echocardiography noted an aberrant vessel arising from the ascending aorta in two of four patients; the etiology of this vessel was uncertain. In the other two patients a diagnosis of coarctation was made. Of the four patients, only one was diagnosed with interruption of the aortic arch. Contrast-enhanced MRA clarified uncertain echocardiographic findings, enabling the correct diagnosis of persistent fifth aortic arch with fourth aortic arch interruption in all four patients. Contrast-enhanced MRA is a safe, accurate, and fast imaging technique for the evaluation of persistent fifth aortic arch and may obviate the need for conventional cine angiography. Cardiac catheterization may be reserved for some types of complicated congenital heart disease and for obtaining hemodynamic information. (orig.)

  11. Early evaluation of coronary artery bypass grafts: CT or selective angiography

    International Nuclear Information System (INIS)

    Wilson, P.C.; Gutierrez, O.; Moss, A.

    1984-01-01

    A prospective study was performed in 27 patients to compare the value of computed tomography and selective angiography in assessing coronary artery graft patency in the early post-operative period. The sensitivity of CT to graft patency was 85% with no falsely patent determinations. Dynamic CT was not found useful in predicting graft stenosis. There were no complications associated with CT studies, and two related to selective angiography. It is concluded that CT is the procedure of choice for graft evaluation in the early post-operative period; but that angiography is mandatory for the assessment of late symptom recurrence. A review is made of the results described in previous series. (orig.)

  12. Determination of Stent Stenosis: An In Vivo Experimental Comparison of Intravascular Ultrasound and Angiography with Histology

    International Nuclear Information System (INIS)

    Schuermann, Karl; Vorwerk, Dierk; Uppenkamp, Robert; Klosterhalfen, Bernd; Buecker, Arno; Guenther, Rolf W.

    1998-01-01

    Purpose: To compare intravascular ultrasound (IVUS) and angiography with histology in determining the degree of stent stenosis in an in vivo experiment. Methods: In 16 sheep, a total of 64 stents were implanted into the external iliac arteries. Two stents were inserted on either side. Patency was followed by angiography and IVUS. Four types of stent were used: two Dacron-covered (Cragg Endopro and heparinized Cragg Endopro) and two non-covered (Cragg and Memotherm stents). Eight animals were killed after 1 month, eight others after 6 months. Histological sections were prepared from the stented vessels. Measurements of the patent and total stent diameters determined by IVUS, angiography, and histology were compared. Results: Correlation between IVUS and angiography was 0.75, between IVUS and histology 0.77, and between angiography and histology 0.85. A mean stent stenosis of 17 ± 11% (range 0-51%) was found on angiography, of 10 ± 11% (0-46%) on IVUS, and of 20 ± 11% (4%-49%) on histology. In comparison with histology, IVUS underestimated the degree of stenosis by 10 ± 8%, and angiography underestimated it by 3 ± 6%. Resolution of IVUS was calculated to be about 0.35 mm and that of angiography to be about 0.15 mm. Conclusion: Under experimental conditions, IVUS was not superior to angiography in determining the degree of stent stenosis in long-segment stenoses of iliac artery stents, when measurements were correlated with histology. Angiography is sufficient for following the patency of iliac artery stents

  13. 'Table step-shift DSA' for peripheral angiography

    International Nuclear Information System (INIS)

    Kojima, Kanji; Seo, Hiroyuki; Kawase, Yoshirou; Hino, Ichirou; Satou, Katashi; Takashima, Hitoshi; Ohkawa, Motoomi; Tamai, Toyosato; Tanabe, Masatada

    1987-01-01

    We developed a new technique of digital subtraction angiography (DSA) for peripheral angiography, which make it possible to obtain DSA images of two contiguous positions with a single injection of contrast material. It is made by the combination with DSA system (Toshiba Digiformer X-03A) and the angio-table with step-shift function (Toshiba CAT-FX), which is widely used in the conventional angiography for pelvis and lower extrimities. When DSA image of the first position is sufficiently demonstrated, the table is semi-automatically translated to the second position by the switching of the operator, observing TV-monitor. The images are stored into the digital image disc. DSA image of the second position can be given by the remasking method. We examined 40 times ''table step-shift DSA'' on 18 patients, which consist of 19 IVDSA with central injection and 21 IADSA for abdomen and lower leg. In 90 % and 72.5 % of images the procedure was diagnostic for the 1st and 2nd position respectively. The causes of nondiagnostic image were mostly from the prolonged blood flow and its difference in both sides. With this technique we could reduce the contrast material load and the time consumption of the examination. (author)

  14. Neurologic complications of cerebral angiography in childhood moyamoya syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, R.L.; Chavali, R.V.; Robson, C.D.; Barnes, P.D.; Burrows, P.E. [Department of Radiology, Children`s Hospital Medical Center, Boston, MA (United States); Eldredge, E.A. [Department of Anesthesia, Children`s Hospital Medical Center and Harvard Medical School, Boston, MA (United States); Scott, R.M. [Department of Neurosurgery, Children`s Hospital Medical Center and Harvard Medical School, Boston, MA (United States)

    1998-11-01

    Purpose. To determine the incidence of neurologic complications of cerebral angiography in children with moyamoya syndrome (MMS) as compared to children without MMS. Materials and methods. One-hundred-ninety consecutive cerebral angiograms obtained in 152 children were evaluated. Sixty of these angiograms were obtained in 40 children with MMS. Patients underwent neurologic evaluation prior to and after the procedure. For this study, a neurologic complication was defined as any new focal neurologic deficit or alteration in mental status occurring during the procedure or within the ensuing 24 hours. Results. There were 2 neurologic complications within 24 hours of angiography, one in the MMS group and one in the non-MMS group. One patient with MMS became mute following angiography. The symptom resolved within 12 hours. One patient without MMS being examined postoperatively for residual arteriovenous malformation developed intracranial hemorrhage requiring reexploration 12 hours after the angiogram. Using a two-tail Fisher`s exact test, there was no significant statistical difference in the ischemic (P = 0.3) or hemorrhagic (P = 1.0) complication rates between the group of patients with MMS and the non-MMS groups. Conclusion. The risk of a neurologic complication from cerebral angiography in children with MMS is low and not statistically different from the risk in children with other cerebrovascular disorders. (orig.) With 8 tabs., 37 refs.

  15. Clinical application of iopamidol (pamiray 300) for cerebral angiography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Ho; Suh, Sang Hyun; Kim, Jin Na; Kim, Eung Yeop; Kim, Dong Joon; Lee, Seung Koo; Kim, Dong Ik [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2007-08-15

    The aim of this study was to assess the clinical safety and efficacy of Pamiray 300 (Iopamidol; Dongkook Pharm, Seoul, Korea) as a nonionic contrast medium for cerebral angiography. One hundred patients undergoing cerebral angiography were randomly assigned to receive Pamiray 300 after written consent had been obtained. Patients with adverse reactions were divided into two groups. One group consisted of patients with minor adverse events such as heat sensation and pain, and the other group consisted of patients with major adverse events such as dyspnea, laryngeal edema and shock. The qualities of the radiographic images were stratified into five grades by three independent radiologists. No abnormality induced by Pamiray 300 was seen by a physical and neurological examination, blood pressure measurement, electrocardiogram, respiration rate measurement and partial fraction of arterial oxygen recording. No major and severe adverse events occurred throughout the study. Patient sex, age, disease category, underlying disease and administered contrast dosage showed no statistical significance with regards to the occurrence of adverse events. The opacification of blood vessels in all patients was 'good' or 'excellent'. Based on the results of this study, Pamiray 300 is a safe, efficacious and well-tolerated contrast medium for use in cerebral angiography. Thus, Pamiray 300 can be used as a competitive medium in cerebral angiography.

  16. Intraoperative digital angiography: Peripheral vascular applications

    International Nuclear Information System (INIS)

    Bell, K.; Reifsteck, J.E.; Binet, E.F.; Fleisher, H.J.

    1986-01-01

    Intraoperative digital angiography is the procedure of choice for the peripheral vascular surgeon who wishes to evaluate his results before terminating anesthesia. Two operating suites at the John L. McClellan Memorial Veterans Hospital are equipped with permanent ceiling-mounted Philips C-arm fluoroscopes and share an ADAC 4100 digital angiographic system. In the last 18 months, 40 peripheral vascular intraoperative digital angiographic procedures have been performed, in all but two cases using direct arterial puncture. In 65% of cases, the intraoperative study showed no significant abnormality. In 12.5%, minor abnormalities not requiring reoperation were seen. In 22.5% of cases, the intraoperative digital angiogram revealed a significant abnormality requiring immediate operative revision. None of the patients who underwent reoperation experienced postoperative sequelae. Intraoperative digital angiography is useful in identifying complications of peripheral vascular operations

  17. The value of 3D-CT angiography and duplex sonography in comparison to arteriography in carotid artery stenoses

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Wesner, F.; Hoepfner, M.; Schwarzenberg, H.; Heller, M.

    1997-01-01

    To determine the value of 3D-CT angiography, duplex sonography in comparison to selective digital subtraction angiography for evaluation of carotid artery stenoses. Methods: 30 patients with 51 stenoses of carotid artery underwent 3D-CT angiography, duplex sonography and angiography. Quantification of stenosis was determined according to the NASCET study and categorized into mild (0-29%), moderate (30-69%), severe (70-99%) and occluded (100%). Results: The agreement of 3D-CT angiography with intraarterial digital subtraction angiography (DSA) was 62% (r=0.89; p [de

  18. Digital subtraction angiography in head and neck radiology

    Energy Technology Data Exchange (ETDEWEB)

    Carmody, R F; Seeger, J F; Smith, R L; Horsley, W W; Miller, R W

    1984-07-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 44 patients with suspected otolaryngologic abnormalities. Sixteen had IVDSA for pulsatile tinnitus or suspected glomus tumor of the petrous bone. Nine patients were evaluated because of pulsatile neck masses, and 12 others had suspected tumors of the neck, face, and paranasal sinuses. Seven had IVDSA following head and neck trauma. The technique of examination is described. The current indications of IVDSA in head and neck radiology are discussed. It is concluded that IVDSA is a suitable substitute for conventional angiography for many otolaryngologic conditions and, because of its safety, can be used more liberally.

  19. Transient cortical blindness following vertebral angiography in a young adult with cerebellar haemangioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Till, Viktor; Stojanovic, Sanja; Avramov, Predrag [Clinical Centre of Vojvodina, Centre of Radiology, Novi Sad (RS); Koprivsek, Katarina [Institute of Oncology, Diagnostic Imaging Department, Sremska Kamenica (RS); Vulekovic, Petar [Clinical Centre of Vojvodina, Neurosurgery Clinic, Novi Sad (RS)

    2009-11-15

    Transient cortical blindness is reported to occur in 0.3% to 1% of cerebral angiography procedures. It develops within minutes of contrast medium injection and lasts for up to several days. We report a long episode of transient cortical blindness in a 17-year-old boy with cerebellar haemangioblastoma, which started during the preoperative vertebral angiography and lasted for 5 days. CT performed 2 days after the sudden onset of bilateral visual loss showed multiple asymmetrical lesions within the brain parenchyma in the distribution of the posterior cerebral circulation. Even though the patient's vision was completely restored 5 days after angiography, repeat MRI performed 2 months after angiography showed improvement but with residual lesions in the thalami, cerebellum and occipital lobe. (orig.)

  20. Whole-body MR angiography with body coil acquisition at 3 T in patients with peripheral arterial disease using the contrast agent gadofosveset trisodium

    DEFF Research Database (Denmark)

    Nielsen, Yousef W; Eiberg, Jonas P; Løgager, Vibeke B

    2009-01-01

    Whole-body magnetic resonance angiography (WB-MRA) at 3 T with body coil acquisition has not previously been investigated. In this study, WB-MRA was performed in this manner using the blood pool contrast agent gadofosveset trisodium.......Whole-body magnetic resonance angiography (WB-MRA) at 3 T with body coil acquisition has not previously been investigated. In this study, WB-MRA was performed in this manner using the blood pool contrast agent gadofosveset trisodium....

  1. Digital subtraction angiography: first 900 cases

    International Nuclear Information System (INIS)

    Rodgers, H.

    1984-01-01

    The diagnostic technique of digital subtraction angiography (DSA) is briefly outlined. The operational and technical experiences with a DR-960 DSA system used in the examination of the first 900 cases at St. Thomas' Hospital, London are described. (U.K.)

  2. Patency of runoff detected by MR angiography at 3.0 T with cuff-compression: a predictor of successful endovascular recanalization below the knee

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Yue-Qi; Zhao, Jun-Gong; Wang, Jue; Tan, Hua-Qiao; Lu, Hai-Tao; Cheng, Ying-Sheng; Wei, Li-Ming; Zhang, Pei-Lei [Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, Department of Diagnostic and Interventional Radiology, Shanghai (China); Liu, Fang [Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, Department of Endocrinology, Shanghai (China)

    2014-11-15

    Our aim was to assess the reliability of detecting distal runoff vessels using contrast-enhanced MR angiography (CE-MRA) that were occult on digital subtraction angiography (DSA) for predicting the outcome of endovascular recanalization (ER). This retrospective analysis comprised 63 patients with diabetes (98 limbs) who underwent ER for infrapopliteal lesions. Before ER, they underwent CE-MRA and DSA for peripheral arterial disease; runoff vessels were detected with CE-MRA, but not with DSA. Immediate and follow-up postoperative outcomes were assessed. Univariate analysis was performed to identify variables associated with successful ER. Successful ER was achieved in 85.7 % of limbs, and runoff score was significantly lower than in failure limbs (5.1 ± 1.1 vs. 6.2 ± 1.3; P < 0.05). During follow-up, sustained ankle-brachial index (ABI) improvement was found in 76.6 % claudication patients, and walking distance improvement in 86.5 %; pain was relieved in 70.6 % of critical limb ischemia (CLI) limbs, ulceration healed in 81.3 %, and limb-salvage rate was 100 %. Restenosis/occlusion rate was higher for patients with CLI at 12 months (48.8 % vs. 96.3 % in claudication; P < 0.01). Runoff score was associated with a significantly higher likelihood of ER success (odds ratio = 4.096, 95 % confidence interval: 2.056-8.158; P < 0.001). Runoff vessels detected using CE-MRA could indicate immediate success and better outcome of ER for infrapopliteal occlusions. (orig.)

  3. Diagnosis of myocardial ischemia combining multiphase postmortem CT-angiography, histology, and postmortem biochemistry.

    Science.gov (United States)

    Vanhaebost, Jessica; Ducrot, Kewin; de Froidmont, Sébastien; Scarpelli, Maria Pia; Egger, Coraline; Baumann, Pia; Schmit, Gregory; Grabherr, Silke; Palmiere, Cristian

    2017-02-01

    The aim of this study was to assess whether the identification of pathological myocardial enhancement at multiphase postmortem computed tomography angiography was correlated with increased levels of troponin T and I in postmortem serum from femoral blood as well as morphological findings of myocardial ischemia. We further aimed to investigate whether autopsy cases characterized by increased troponin T and I concentrations as well as morphological findings of myocardial ischemia were also characterized by pathological myocardial enhancement at multiphase postmortem computed tomography angiography. Two different approaches were used. In one, 40 forensic autopsy cases that had pathological enhancement of the myocardium (mean Hounsfield units ≥95) observed at postmortem angiography were retrospectively selected. In the second approach, 40 forensic autopsy cases that had a cause of death attributed to acute myocardial ischemia were retrospectively selected. The preliminary results seem to indicate that the identification of a pathological enhancement of the myocardium at postmortem angiography is associated with the presence of increased levels of cardiac troponins in postmortem serum and morphological findings of ischemia. Analogously, a pathological enhancement of the myocardium at postmortem angiography can be retrospectively found in the great majority of autopsy cases characterized by increased cardiac troponin levels in postmortem serum and morphological findings of myocardial ischemia. Multiphase postmortem computed tomography angiography is a useful tool in the postmortem setting for investigating ischemically damaged myocardium.

  4. Digital subtraction angiography in traumatology

    International Nuclear Information System (INIS)

    Steudel, A.; Harder, T.; Lackner, K.; Schneider, B.; Orellano, L.; Bonn Univ.; Bonn Univ.

    1986-01-01

    The methods, indications and results of digital subtraction angiography in traumatology are presented, based on 56 examinations. The different use of intravenous or intraarterial DSA will be discussed with respect to expanding and localisation of traumatic vascular injury. DSA is recommended as the method of choice for follow-up after vascular reconstructive procedure. (orig.) [de

  5. Angiography-based C-arm CT for the assessment of extrahepatic shunting before radioembolization

    International Nuclear Information System (INIS)

    Heusner, Till Alexander; Hahn, S.; Forsting, M.; Antoch, G.; Hamami, M.E.; Poeppel, T.; Bockisch, A.; Ertle, J.; Hilgard, P.

    2010-01-01

    Purpose: to retrospectively assess the accuracy of angiography-based C-arm CT for the detection of extrahepatic shunting before SIRT. Materials and methods: 30 patients (mean age: 64 ± 12 years) with hypervascularized hepatic tumors underwent hepatic angiography, coil embolization of gastrointestinal collaterals and 99mTc-macroaggregated albumin (MAA) SPECT/CT before SIRT. Before MAA injection via a microcatheter from the intended treatment position, an angiography and angiography-based C-arm CT (XperCT trademark, Philips Healthcare) were acquired. Angiographies and XperCT trademark were performed from 48 microcatheter positions followed by MAA injections and MAA-SPECT/CT. MAA-SPECT/CT served as the reference standard for determining the accuracy of hepatic arteriography and C-arm CT for the detection of extrahepatic shunting. Results: MAA-SPECT/CT revealed extrahepatic shunting in 5 patients (17%). Hepatic arteriography yielded a true negative in 22 (73%), a false negative in 5 (17%), and an unclear result in 3 patients (10%). C-arm CT yielded a true positive in 3 (10%), true negative in 24 (80%), false positive in 1 (3%), and false negative in 2 patients (7%). The specificity and the NPV of hepatic arteriography for the detection of extrahepatic shunting were 88% and 81%, respectively. For C-arm CT the sensitivity, specificity, PPV, NPV, and accuracy for the detection of extrahepatic shunting were 60%, 96%, 75%, 92%, and 90%, respectively. Conclusion: C-arm CT offers additional information to angiography when assessing SIRT patients for extrahepatic shunting. More accurate detection of extrahepatic shunting may optimize the workflow in SIRT preparations by avoiding unnecessary repeat angiographies. (orig.)

  6. Radiation Exposure During Uterine Fibroid Embolization (UFE): A Confounder-Controlled Comparison Between a State-of-the-Art Angiography Unit and a Conventional Angiography unit.

    Science.gov (United States)

    Sommer, Christof-Matthias; Voigt, Wieland; Klapp Oliger, Michel; Schlett, Christopher L; Erpenbach, Stefan; Thomas, Katrina; Hatopp, Andreas; Kurz, Patrick; Richter, Goetz M

    2018-03-01

     To compare radiation exposure of a state-of-the-art and a conventional angiography unit in patients undergoing uterine fibroid embolization (UFE).  Between January 2009 and December 2016, 286 patients underwent UFE in our Interdisciplinary Fibroid Center. The inclusion criteria for this retrospective analysis were first-time transarterial embolization for symptomatic fibroids, bilateral embolization, procedures applying a state-of-the-art (Group 1) or a conventional angiography unit (Group 2), and bilateral technical success with an adequate embolization endpoint after the injection of microspheres. Study endpoints included radiation exposure, major complications, morphological success (MRI), and clinical success (questionnaire on quality-of-life). Propensity score matching controlled for confounders.  The inclusion criteria were met by 58 (Group 1) and 177 (Group 2) patients. After propensity score matching, there was no significant difference between Group 1 (n = 46) and Group 2 (n = 92) regarding age, body-mass index, volume of the dominant fibroid and the uterus, fluoroscopy time, and amount of embolic agent (p ≥ 0.10 each). The dose-area product was significantly lower in Group 1 than in Group 2 (1159.0 cGycm 2 vs. 3123.5 cGycm 2 ; p  0.99). There were no significant differences between both groups regarding shrinkage of the dominant fibroid and the uterus and no relevant differences regarding patient-reported quality-of-life.  A state-of-the-art angiography unit has the potential to reduce radiation exposure in patients undergoing UFE without increasing the risk of major complications and with comparably high morphological and clinical success.   · A state-of-the-art angiography unit potentially reduces radiation exposure in patients undergoing UFE.. · Reduced radiation exposure does not seem to negatively influence the rate of major complications.. · Reduced exposure does not seem to negatively affect morphological and clinical

  7. A quantitative study of ramped radio frequency, magnetization transfer, and slab thickness in three-dimensional time-of-flight magnetic resonance angiography in a patient population.

    Science.gov (United States)

    Goodrich, K C; Blatter, D D; Parker, D L; Du, Y P; Meyer, K J; Bernstein, M A

    1996-06-01

    The authors compare the effectiveness of various magnetic resonance (MR) angiography acquisition strategies in enhancing the visibility of small intracranial vessels. Blood vessel contrast-to-noise ratio (CNR) in time-of-flight MR angiography was studied as a function of vessel size and several selectable imaging parameters. Contrast-to-noise measurements were made on 257 vessel segments ranging in size from 0.3 mm to 4.2 mm in patients who recently had undergone intraarterial cerebral angiography. Imaging parameters studied included magnetization transfer, spatially variable radio frequency (RF) pulse profile (ramped RF), and imaging slab thickness. The combination of thin slabs (16 slices/slab), ramped RF, and magnetization transfer resulted in the highest CNR for all but the smallest vessel sizes. The smallest vessels (slab (64 slices/slab) with ramped RF and magnetization transfer. Magnetization transfer always improved vessel CNR, but the improvement diminished as the slab thickness was reduced. The CNR increased with a decrease in slab thickness for all but the smallest vessel sizes. Overall, the results provide a quantitative demonstration that inflow enhancement of blood is reduced for small vessels. Thus, whereas magnetization transfer is important at all vessel sizes, it becomes the primary factor in improving the visibility of the smallest vessels.

  8. Descriptive retrospective analysis of the diagnostic yield and morbidity of four vessel catheter-directed cerebral angiography and multidetector computed tomographic angiography (MDCTA) performed at Inkosi Albert Luthuli Central Hospital (IALCH)

    International Nuclear Information System (INIS)

    Sabri, A.; Robbs, J.V.; Maharajh, J.; Sikwila, T.C.

    2011-01-01

    Imaging studies are indispensable in order to determine the source, location and pattern of intra and extra-axial brain haemorrhages. In our study of 277 patients carried out over an 18 month period, the most common reason of referral was subarachnoid haemorrhage followed by trauma. Aneurysms were the most common diagnosis (36%) with anterior and posterior communicating arteries being the most common locations. Fifty percent (50%) of patients investigated had a normal study. Our findings show that the yield from MDCTA and conventional angiography was relatively comparable, however, conventional angiography was superior in detection of aneurysms; hence, in cases were the MDCTA result was found to be normal despite a high index of suspicion for a subarachnoid haemorrhage, a follow-up MDCTA study or conventional angiography is useful. Moreover, conventional angiography was superior in detection of multiple aneurysms.

  9. Descriptive retrospective analysis of the diagnostic yield and morbidity of four vessel catheter-directed cerebral angiography and multidetector computed tomographic angiography (MDCTA) performed at Inkosi Albert Luthuli Central Hospital (IALCH)

    Energy Technology Data Exchange (ETDEWEB)

    Sabri, A., E-mail: sabri.ali@gmail.com [University of Kwazulu Natal, College of Health Sciences, Nelson R Mandela School of Medicine, School of Surgical Disciplines, Department of Radiology, Private Bag 7, Congella 4013, Durban (South Africa); Robbs, J.V., E-mail: jvrobbs@mweb.co.za [University of Kwazulu Natal, College of Health Sciences, Nelson R Mandela School of Medicine, School of Surgical Disciplines, Department of Surgery, Durban (South Africa); Maharajh, J., E-mail: Jaynund.Maharajh@kznhealth.gov.za [University of Kwazulu Natal, College of Health Sciences, Nelson R Mandela School of Medicine, School of Surgical Disciplines, Department of Radiology, Private Bag 7, Congella 4013, Durban (South Africa); Sikwila, T.C., E-mail: tcsikwila@yahoo.co.uk [University of Kwazulu Natal, College of Health Sciences, Nelson R Mandela School of Medicine, School of Surgical Disciplines, Department of Radiology, Private Bag 7, Congella 4013, Durban (South Africa)

    2011-11-15

    Imaging studies are indispensable in order to determine the source, location and pattern of intra and extra-axial brain haemorrhages. In our study of 277 patients carried out over an 18 month period, the most common reason of referral was subarachnoid haemorrhage followed by trauma. Aneurysms were the most common diagnosis (36%) with anterior and posterior communicating arteries being the most common locations. Fifty percent (50%) of patients investigated had a normal study. Our findings show that the yield from MDCTA and conventional angiography was relatively comparable, however, conventional angiography was superior in detection of aneurysms; hence, in cases were the MDCTA result was found to be normal despite a high index of suspicion for a subarachnoid haemorrhage, a follow-up MDCTA study or conventional angiography is useful. Moreover, conventional angiography was superior in detection of multiple aneurysms.

  10. National Synchrotron Light Source angiography personnel protection interlock

    International Nuclear Information System (INIS)

    Gmuer, N.; Larson, R.; Thomlinson, W.

    1992-06-01

    This document has been written to describe the safety system operation at the NSLS X17B2 beamline Synchrotron Medical Research Facility (SMERF). The angiography exposure process involves scanning a patient up and down through dual fixed-position x-ray beams; exposure is controlled by opening and closing a fast-acting Safety Shutter mechanism at precise times in relation to the up and down motion of the scan chair. The fast-acting Safety Shutter mechanism is the primary radiation-stopping element protecting the patient while the chair is at rest and while it is reversing directions during the scan. Its fail-safe and fast operation is essential for the safety of the patient. Operation of X17B2 as a human subject angiography station necessitates the implementation of a personnel protection interlock system that, in conjunction with the Safety Shutters: permits safe access to the patient exposure area while the synchrotron radiation beam is illuminating the upstream dual energy monochromator; allows a patient to be imaged by the monochromatized beam under the supervision of a Responsible Physician, with scan chair motion and precision shutter actuation regulated by an angiography control computer, while providing a suitable number of safeguards against accidental radiation exposure; has different modes of operation to accommodate equipment set-up, test, and calibration; and patient exposure; and ensures the quick extinction of the beam if a potentially unsafe condition is detected. The interlock system which performs these safety functions is called the Angiography Personnel Protection Interlock (APPI). The APPI Document is organized such that the level of detail changes from a general overview to detailed engineering drawings of the hardware system

  11. National Synchrotron Light Source angiography personnel protection interlock

    Energy Technology Data Exchange (ETDEWEB)

    Gmuer, N.; Larson, R.; Thomlinson, W.

    1992-06-01

    This document has been written to describe the safety system operation at the NSLS X17B2 beamline Synchrotron Medical Research Facility (SMERF). The angiography exposure process involves scanning a patient up and down through dual fixed-position x-ray beams; exposure is controlled by opening and closing a fast-acting Safety Shutter mechanism at precise times in relation to the up and down motion of the scan chair. The fast-acting Safety Shutter mechanism is the primary radiation-stopping element protecting the patient while the chair is at rest and while it is reversing directions during the scan. Its fail-safe and fast operation is essential for the safety of the patient. Operation of X17B2 as a human subject angiography station necessitates the implementation of a personnel protection interlock system that, in conjunction with the Safety Shutters: permits safe access to the patient exposure area while the synchrotron radiation beam is illuminating the upstream dual energy monochromator; allows a patient to be imaged by the monochromatized beam under the supervision of a Responsible Physician, with scan chair motion and precision shutter actuation regulated by an angiography control computer, while providing a suitable number of safeguards against accidental radiation exposure; has different modes of operation to accommodate equipment set-up, test, and calibration; and patient exposure; and ensures the quick extinction of the beam if a potentially unsafe condition is detected. The interlock system which performs these safety functions is called the Angiography Personnel Protection Interlock (APPI). The APPI Document is organized such that the level of detail changes from a general overview to detailed engineering drawings of the hardware system.

  12. Mono-energy coronary angiography with a compact light source

    Science.gov (United States)

    Eggl, Elena; Mechlem, Korbinian; Braig, Eva; Kulpe, Stephanie; Dierolf, Martin; Günther, Benedikt; Achterhold, Klaus; Herzen, Julia; Gleich, Bernhard; Rummeny, Ernst; Noël, Peter B.; Pfeiffer, Franz; Muenzel, Daniela

    2017-03-01

    While conventional x-ray tube sources reliably provide high-power x-ray beams for everyday clinical practice, the broad spectra that are inherent to these sources compromise the diagnostic image quality. For a monochromatic x-ray source on the other hand, the x-ray energy can be adjusted to optimal conditions with respect to contrast and dose. However, large-scale synchrotron sources impose high spatial and financial demands, making them unsuitable for clinical practice. During the last decades, research has brought up compact synchrotron sources based on inverse Compton scattering, which deliver a highly brilliant, quasi-monochromatic, tunable x-ray beam, yet fitting into a standard laboratory. One application that could benefit from the invention of these sources in clinical practice is coronary angiography. Being an important and frequently applied diagnostic tool, a high number of complications in angiography, such as renal failure, allergic reaction, or hyperthyroidism, are caused by the large amount of iodine-based contrast agent that is required for achieving sufficient image contrast. Here we demonstrate monochromatic angiography of a porcine heart acquired at the MuCLS, the first compact synchrotron source. By means of a simulation, the CNR in a coronary angiography image achieved with the quasi-mono-energetic MuCLS spectrum is analyzed and compared to a conventional x-ray-tube spectrum. The results imply that the improved CNR achieved with a quasi-monochromatic spectrum can allow for a significant reduction of iodine contrast material.

  13. Comparison of fluoro and cine coronary angiography: balancing acceptable outcomes with a reduction in radiation dose.

    Science.gov (United States)

    Olcay, Ayhan; Guler, Ekrem; Karaca, Ibrahim Oguz; Omaygenc, Mehmet Onur; Kizilirmak, Filiz; Olgun, Erkam; Yenipinar, Esra; Cakmak, Huseyin Altug; Duman, Dursun

    2015-04-01

    Use of last fluoro hold (LFH) mode in fluoroscopy, which enables the last live image to be saved and displayed, could reduce radiation during percutaneous coronary intervention when compared with cine mode. No previous study compared coronary angiography radiation doses and image quality between LFH and conventional cine mode techniques. We compared cumulative dose-area product (DAP), cumulative air kerma, fluoroscopy time, contrast use, interobserver variability of visual assessment between LFH angiography, and conventional cine angiography techniques. Forty-six patients were prospectively enrolled into the LFH group and 82 patients into the cine angiography group according to operator decision. Mean cumulative DAP was higher in the cine group vs the LFH group (50058.98 ± 53542.71 mGy•cm² vs 11349.2 ± 8796.46 mGy•cm²; Pcine group vs the LFH group (3.87 ± 5.08 minutes vs 1.66 ± 1.51 minutes; Pcine group vs the LFH group (112.07 ± 43.79 cc vs 88.15 ± 23.84 cc; Pcine and LFH angiography groups (0.66680 ± 0.19309 vs 0.54193 ± 0.31046; P=.20). Radiation doses, contrast use, and fluoroscopy times are lower in fluoroscopic LFH angiography vs cine angiography. Interclass variability of visual stenosis estimation between three operators was not different between cine and LFH groups. Fluoroscopic LFH images conventionally have inferior diagnostic quality when compared with cine coronary angiography, but with new angiographic systems with improved LFH image quality, these images may be adequate for diagnostic coronary angiography.

  14. Rest and exercise radionuclide angiography for diagnosis in chronic ischemic heart disease

    International Nuclear Information System (INIS)

    Gibbons, R.J.

    1991-01-01

    Rest and exercise radionuclide angiography is frequently employed for the diagnosis of chest pain syndromes. Its value and limitations in this regard have been well studied, but proper utilization of the technique requires an understanding of five critical concepts: (1) Radionuclide angiography is superior to treadmill exercise testing and probably equivalent to thallium scintigraphy, although the published series did not use current methods. (2) The true specificity of radionuclide angiography is about 80%, intermediate between the early optimistic estimates and the later pessimistic ones. (3) The peak exercise ejection fraction is the preferred test parameter for diagnosis, although exercise hemodynamics, symptoms, and electrocardiographic changes should also be considered. (4) Although radionuclide angiography is clearly helpful for noninvasive diagnosis, significant numbers of patients will continue to fall in an uncertain category. (5) The proper application of the technique requires recognition of its limitations and careful attention to technical details. When properly applied, this modality can make an important contribution to clinical decision making. 58 references

  15. Diagnosis of echinococcosis of the liver by angiography

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, K.; Treugut, H.; Mahnke, B.; Barth, V.

    1980-07-01

    Twenty patients with Echinococcus cysticus and 15 with E. alveolaris were studied. Selective upper abdominal angiographies, performed in most of these cases, were reviewed retrospectively for typical angiographic changes. In a large percentage, E. cysticus demonstrated typical cystic and expansive signs; atypical vessels were rarely seen. How the 'rim sign' develops is demonstrated. Usual signs of E. alveolaris are incomplete solid and necrotic space occupying lesions, as seen also in malignancy. Although angiography offers a high diagnostic rate in hepatic manifestation of this parasitic disease, it has been superseded today by sonography and computer tomography. It is, however, still a valuable investigation in pre-operative work-up.

  16. Diagnosis of echinococcosis of the liver by angiography

    International Nuclear Information System (INIS)

    Schulze, K.; Treugut, H.; Mahnke, B.; Barth, V.; Katharinenhospital, Stuttgart

    1980-01-01

    Twenty patients with Echinococcus cysticus and 15 with E. alveolaris were studied. Selective upper abdominal angiographies, performed in most of these cases, were reviewed retrospectively for typical angiographic changes. In a large percentage, E. cysticus demonstrated typical cystic and expansive signs; atypical vessels were rarely seen. How the 'rim sign' develops is demonstrated. Usual signs of E. alveolaris are incomplete solid and necrotic space occupying lesions, as seen also in malignancy. Although angiography offers a high diagnostic rate in hepatic manifestation of this parasitic disease, it has been superseded today by sonography and computer tomography. It is, however, still a valuable investigation in pre-operative work-up. (orig.) [de

  17. Digital subtraction angiography in head and neck radiology

    International Nuclear Information System (INIS)

    Carmody, R.F.; Seeger, J.F.; Smith, R.L.; Horsley, W.W.; Miller, R.W.

    1984-01-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 44 patients with suspected otolaryngologic abnormalities. Sixteen had IVDSA for pulsatile tinnitus or suspected glomus tumor of the petrous bone. Nine patients were evaluated because of pulsatile neck masses, and 12 others had suspected tumors of the neck, face, and paranasal sinuses. Seven had IVDSA following head and neck trauma. The technique of examination is described. The current indications of IVDSA in head and neck radiology are discussed. It is concluded that IVDSA is a suitable substitute for conventional angiography for many otolaryngologic conditions and, because of its safety, can be used more liberally. (orig.)

  18. Renal computed angiography. Part I: Renal CT arteriography in hypertension

    International Nuclear Information System (INIS)

    Al-Amin, M.; Hadjidekov, V.

    2012-01-01

    Visualization of renal vasculature is needed in several clinical condition among which hypertension is dominant. CT angiography now day replaces catheter angiography as non-invasive method. The goal of this study is to present initial authors experience in visualization of renal arteries using 64 MDCT and to evaluated the utility in hypertensive patients. MDCT assures excellent assessment of renal arteries conditions. Multiplanar reconstruction and allow better delineation in tortuous vessels course and anatomic variants. (authors)

  19. Gallbladder visualization on CT shortly after abdominal angiography with iodixanol

    International Nuclear Information System (INIS)

    Tajima, Hiroyuki; Murakami, Ryusuke; Goto, Shinsuke; Aoyama, Toshiya; Kaizu, Toshihide; Ichikawa, Taro; Kumazaki, Tatsuo; Onda, Masahiko

    1996-01-01

    Fifteen patients underwent CT examination shortly after abdominal angiography with iodixanol. Gallbladder opacification was observed in 13 patients in the absence of clinical evidence of renal impairment. Among them, 2 patients showed a strong opacification on CT. There was no significant relationship between visualization of the gallbladder and the total dose of contrast medium. Gallbladder opacification on CT examination shortly after angiography shows that the hepatobiliary tract is important in the excretion of iodixanol. (author)

  20. Transient global amnesia after cerebral angiography still occurs: Case report and literature review

    DEFF Research Database (Denmark)

    Foss-Skiftesvik, Jon; Snoer, Agneta Henriette; Wagner, Aase

    2014-01-01

    Transient global amnesia is considered a very rare complication of diagnostic cerebral angiography, and has only been reported in a limited number of case reports more than 15 years ago. We describe a patient experiencing transient global amnesia following cerebral digital subtraction angiography....... While the condition by definition is self-limiting, its differential diagnoses may cause severe morbidity and/or mortality if left untreated. It is therefore important to build and maintain awareness of transient global amnesia as a possible complication of cerebral angiography....

  1. Magnetic resonance angiography of the pediatric abdomen and pelvis: techniques and imaging findings.

    Science.gov (United States)

    Sada, David M; Vellody, Ranjith; Liu, Peter S

    2013-11-01

    Although traditional catheter-based angiography has been the gold standard for pediatric abdominal and pelvic vascular imaging for the past several decades, advances in magnetic resonance angiography (MRA) have made it a viable alternative. MRA offers several advantages in that it is noninvasive, can be performed without ionizing radiation, and does not necessarily rely on contrast administration. The ability of modern MRA techniques to define variant vascular anatomy and detect vascular disease may obviate traditional angiography in some patients. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. MR Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types

    Directory of Open Access Journals (Sweden)

    Matthias C. Burg

    2011-01-01

    Full Text Available Purpose. To evaluate stent lumen visibility of a large sample of different peripheral arterial (iliac, renal, carotid stents using magnetic resonance angiography in vitro. Materials and Methods. 21 different stents and one stentgraft (10 nitinol, 7 316L, 2 tantalum, 1 cobalt superalloy, 1 PET + cobalt superalloy, and 1 platinum alloy were examined in a vessel phantom (vessel diameters ranging from 5 to 13 mm filled with a solution of Gd-DTPA. Stents were imaged at 1.5 Tesla using a T1-weighted 3D spoiled gradient-echo sequence. Image analysis was performed measuring three categories: Signal intensity in the stent lumen, lumen visibility of the stented lumen, and homogeneity of the stented lumen. The results were classified using a 3-point scale (good, intermediate, and poor results. Results. 7 stents showed good MR lumen visibility (4x nitinol, 2x tantalum, and 1x cobalt superalloy. 9 stents showed intermediate results (5x nitinol, 2x 316L, 1x PET + cobalt superalloy, and 1x platinum alloy and 6 stents showed poor results (1x nitinol, and 5x 316L. Conclusion. Stent lumen visibility varies depending on the stent material and type. Some products show good lumen visibility which may allow the detection of stenoses inside the lumen, while other products cause artifacts which prevent reliable evaluation of the stent lumen with this technique.

  3. Digital subtraction angiography and intraarterial contrast medium injection for coronary examinations

    Energy Technology Data Exchange (ETDEWEB)

    Tobio, R; Kallmeyer, C; Castello, J

    1985-01-01

    Digital subtraction angiography (DSA) is an established method of vasography, most extensively used as i.v. DSA. Intraarterial injection, however, applying selective or non-selective contrast medium injection, seems to be at least as important a technique although it has not yet met with corresponding interest. The article explains advantages of the technique for angiographic examinations, in particular of coronary angiography.

  4. Focal time-to-peak changes on perfusion MRI in children with Moyamoya disease: correlation with conventional angiography

    International Nuclear Information System (INIS)

    Choi, Hyun Seok; Kim, Dong-Seok; Shim, Kyu-Won; Kim, Jinna; Kim, Eun Soo; Lee, Seung-Koo

    2011-01-01

    Background: Moyamoya disease is a chronic progressive steno-occlusion of the distal internal carotid arteries with unknown etiology. As the classical presentation of childhood Moyamoya disease is ischemic stroke, cerebral hemodynamic evaluation is important for patient selection for surgery to prevent recurrent ischemic attacks. Perfusion MR imaging has been applied to evaluate cerebral hemodynamics. Purpose: To correlate the 'basal time-to-peak preservation sign', 'auto-synangiosis sign', and 'posterior involvement sign' on time-to-peak map of perfusion MRI with catheter angiography. Material and Methods: Thirty-four children (6.91 ± 3.08 years) with Moyamoya disease who underwent both perfusion-weighted MRI and catheter angiography were enrolled in this study. Given catheter angiography as a reference standard, basal time-to-peak preservation sign, auto-synangiosis sign, and posterior involvement sign were evaluated on time-to-peak maps. Results: The basal time-to-peak preservation sign was accurate for the diagnosis of childhood Moyamoya disease; both sensitivity and specificity were 100%. The auto-synangiosis sign showed lower sensitivity (65%), however, with an acceptable specificity (98%). The posterior involvement sign showed lower sensitivity (61%) but had an acceptable specificity (96%). Conclusion: The basal time-to-peak preservation sign may be a universal finding in childhood Moyamoya disease. The auto-synangiosis and posterior involvement sign may be useful in determining transdural collateral status and posterior circulation involvement in childhood Moyamoya disease

  5. Data on copper level in the blood of patients with normal and abnormal angiography

    Directory of Open Access Journals (Sweden)

    Leila Amiri

    2016-12-01

    Full Text Available In this data article, we measured the levels of copper in the blood of patients undergoing coronary angiography. The samples were taken from patients with cardiovascular disease in Bushehr׳s university hospital, Iran. Patients were divided in two groups: normal angiography and abnormal angiography. After the chemical digestion of samples, the concentration levels of Cu in both groups were determined by using inductively coupled plasma optical spectrometry (ICP-OES.

  6. Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Koike, Yuya, E-mail: r06118@hotmail.co.jp; Nishimura, Jun-ichi, E-mail: jun-ichi-n@nifty.com; Hase, Soichiro, E-mail: haseman@hotmail.co.jp; Yamasaki, Motoshige, E-mail: genyamasaki@gmail.com [Kawasaki Saiwai Hospital, Department of Interventional Radiology (Japan)

    2015-04-15

    PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasation of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.

  7. Angiography of histopathologic variants of synovial sarcoma

    International Nuclear Information System (INIS)

    Lois, J.F.; Fischer, H.J.; Mirra, J.M.; Gomes, A.S.; California Univ., Los Angeles

    1986-01-01

    Synovial sarcomas are rare soft tissue tumors which histopathologically can be divided into monophasic, biphasic and mixed variants. As part of a protocol for intra-arterial chemotherapy 12 patients with biopsy proven synovial sarcoma underwent angiography. The angiograms on these patients were reviewed to determine whether synovial sarcomas and their variants demonstrated a characteristic angiographic appearance. Synovial sarcomas appeared angiographically as soft tissue masses which showed a fine network of tumor vessels with an inhomogeneous capillary blush. Their degree of vascularity varied according to their histopathology. Monophasic synovial sarcomas demonstrated in general a higher degree of neovascularity than the biphasic form. This finding was also suggested by histopathologic analysis of the vessels in the tumor. Although angiography did not show a distinctive vascular pattern it may be useful to evaluate tumor size and vascularity. (orig.)

  8. Scimitar syndrome: multi detector computed tomography angiography findings of a case

    International Nuclear Information System (INIS)

    Aslan, A.; Bozlar, U.; Ors, F.; Tasar, M.

    2012-01-01

    Full text: Introduction: Scimitar syndrome also known as pulmonary venolobar syndrome is a rare congenital abnormality. This abnormality consists of ipsilateral anomalous pulmonary venous drainage of right lung into the inferior vena cava (IVC), with hypoplasia of the right lung, an anomalous systemic arterial supply from supradiaphragmatic aorta to the right lower lobe and dextrocardia. Objectives and tasks: In this article, we aimed to present multidetector computed tomography (MDCT) angiography findings of a case with scimitar syndrome. Material and methods: 21 year old male with dextrocardia and anomalous curvilinear density in the right lower lobe directed toward the right hemidiaphragm on chest radiography was evaluated with MDCT angiography examination. Results: Dextrocardia and interruption of IVC with azygous continuation was detected in MDCT angiography examination. Vertically directing right superior pulmonary vein was draining to the suprahepatic segment of IVC. Pulmonary sequestration in the right lower lobe taking feeder from celiac trunk was detected. Right pulmonary artery was hypoplastic and bronchial tree was abnormal, manifesting as a mirror image in both lung lobes. Conclusion: MDCT angiography is very successful imaging method in demonstrating the anomalous pulmonary vein and assessing pulmonary arterial and bronchial anomalies

  9. Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: Comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Pozzi-Mucelli, Fabio; Bruni, Stefano; Doddi, Marco; Calgaro, Antonio; Braini, Massimiliano; Cova, Maria

    2007-01-01

    Purpose: To compare the contribution of 64 channel multidetector row computed tomography angiography (64MDCT-angiography) with digital subtraction angiography (DSA) in the detection of intracranial aneurysms. Methods and materials: Twenty-nine patients (10 males and 19 females, age: 40-84 years; average: 61.9 years) with clinical and imaging findings strongly suggesting the presence of subaracnoid hemorrhage underwent 64MDCT-angiography and DSA with a short interval between the two examinations (less than 12 h-5 days). CT parameters were: 64 mm x 0.5 mm collimation, pitch-0.828 and helical pitch-53. DSA were performed with standard technique (four vessel catheterization) and multiple projections. Axial CT scans as well as maximum intensity projection, volume rendering and multiplanar reformations and angiographic views were independently reviewed by four readers (two for 64MDCT-angiography and two for DSA). Consensus was reached for discordant cases. DSA was considered as the standard of reference. Results: In 29 patients, 28 aneurysms were found (14 patients had 1 aneurysm, 4 patients had 2 aneurysms and 2 patients had 3 aneurysms; in 9 patients no aneurysm were found). 64MDCT-angiography detected 26/28 aneurysms. No false-positive sites were recognized. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 92.8, 100, 100, 99.4 and 99.5%. Conclusions: 64MDCT-angiography is helpful in detecting intracranial aneurysms with results similar to those of DSA but with less discomfort and risks for the patients and can be considered for the first line imaging technique. Conventional angiography is still needed in doubtful cases or negative MDCT-angiography associated with a strong clinical suspect

  10. The Efficacy of Iopamidol (Pamiray 370) in Aortic and Extremity CT Angiography

    International Nuclear Information System (INIS)

    Lee, Yoo Jin; Lee, Jong Min; Lee, Hui Joong; Park, Ji Won

    2010-01-01

    To evaluate the clinical safety and radiological feasibility of a domestic iopamidol-based contrast media (Pamiray 370) during an aortic and extremity CT angiography. Between August and December of 2008, 100 patients (M:F=51:49; mean age, 59 years) underwent an aortic and extremity CT angiography using Pamiray 370 based with informed consent. All changes in vital signs, clinical symptoms, and adverse reactions to the contrast media were monitored. Two radiologists assessed the image quality of the CT angiography. A statistical comparison was conducted using an independent t-test and a Mann-Whitney test based on the 100-patient group studied using Optiray 350. The contrast enhancement of the descending aorta in the arterial phase showed a statistically greater efficacy (p<0.001) of Pamiray 370 compared to Optiray 350, which was the routine contrast media for CT angiography for our institute. Adverse reaction signs were evident in 3%(3/100) of the subjects. All of them showed mild and transient reactions such as vomiting (n=2) and coughing (n=1), with no medical treatment required. Contrast media related symptoms including dizziness (n=7), nausea (n=3), headaches (n=2), and injection site pain (n=1), were noted in 12%(12/100). The clinical efficacy of Pamiray 370 was acceptable for the aortic and extremity CT angiography, in terms of clinical safety, tolerance, and image quality

  11. Detection of intra-cardiac thrombi and congestive heart failure in cats using computed tomographic angiography.

    Science.gov (United States)

    Vititoe, Kyle P; Fries, Ryan C; Joslyn, Stephen; Selmic, Laura E; Howes, Mark; Vitt, Jordan P; O'Brien, Robert T

    2018-04-16

    Arterial thromboembolism is a life-threatening condition in cats most commonly secondary to cardiac disease. Echocardiography is the reference standard to evaluate for presence of a thrombus. In humans, computed tomographic (CT) angiography is becoming widely used to detect left atrial thrombi precluding the use of sedation. The purpose of this prospective, controlled, methods comparison pilot study was threefold: (1) describe new CT angiography protocol used in awake cats with cardiac disease and congestive heart failure; (2) determine accuracy of continuous and dynamic acquisition CT angiography to identify and characterize cardiac thrombi from spontaneous echocardiographic contrast using transthoracic echocardiography as our reference standard; (3) identify known negative prognostic factors and comorbidities of the thorax that CT angiography may provide that complement or supersede echocardiographic examination. Fourteen cats with heart disease were recruited; 7 with thrombi and 7 with spontaneous echocardiographic contrast. Echocardiography and awake CT angiography were performed using a microdose of contrast. Six of 7 thrombi were identified on CT angiography as filling defects by at least one reviewer within the left auricle (n = 6) and right heart (n = 1). Highest sensitivity (71.4%) was in continuous phase and highest specificity (85.7%) was in dynamic studies with fair to moderate interobserver agreement (0.38 and 0.44). CT angiography identified prognostic cardiac information (left atrial enlargement, congestive heart failure, arterial thromboembolism) and comorbidities (suspected idiopathic pulmonary fibrosis, asthma). This study indicates CT angiography can readily identify cardiac thrombi, important prognostic information and comorbidities, and can be safely performed in cats with cardiac disease and congestive heart failure. © 2018 American College of Veterinary Radiology.

  12. Advantages of time-resolved contrast-enhanced 4D MR angiography in splenic arterial steal syndrome.

    Science.gov (United States)

    Obmann, Verena C; Chalian, Majid; Mansoori, Bahar; Sanchez, Edmund; Gulani, Vikas

    2018-03-07

    Splenic artery steal syndrome (SASS) is a severe complication affecting up to 10% of orthotopic liver transplant (OLT) patients. In this case report, we present a 35-year-old male with OLT secondary to liver failure due to hemochromatosis, who developed SASS. We describe potential application of different imaging techniques for diagnosis of SASS with focus on the value of time-resolved contrast enhanced 4D magnetic resonance angiography (MRA). Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Radiation exposure in X-ray angiography and comparisons between digital and conventional methods of imaging

    International Nuclear Information System (INIS)

    Schaberg, J.

    1987-01-01

    The more recent developments and techniques in the field of angiography are examined for associated radiation exposure risks for patients and investigators and then compared to the conventional methods of angiography. It could be shown that digital subtraction angiography is generally associated with a lesser risk of somatic exposure of the patient, provided that the equipment used offers an adjustable useful-beam range and focus. The fact that above-table X-ray tubes are now generally replaced with X-ray systems installed under the examination table permits the relatively high doses, to which investigators are exposed during angiography, to be reduced by a factor of 3. (DG) [de

  14. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children

    Energy Technology Data Exchange (ETDEWEB)

    Ayyala, Rama S.; Lee, Edward Y. [Boston Children' s Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Zurakowski, David [Boston Children' s Hospital and Harvard Medical School, Departments of Anesthesiology and Surgery, Boston, MA (United States)

    2015-11-15

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  15. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children

    International Nuclear Information System (INIS)

    Ayyala, Rama S.; Lee, Edward Y.; Zurakowski, David

    2015-01-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  16. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children.

    Science.gov (United States)

    Ayyala, Rama S; Zurakowski, David; Lee, Edward Y

    2015-11-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  17. Spiral CT-angiography of the aorta

    NARCIS (Netherlands)

    Balm, R.; Eikelboom, B. C.; van Leeuwen, M. S.; Noordzij, J.

    1994-01-01

    AIMS: To determine whether the new technique of CT-angiography was accurate in displaying the complex anatomy of the aorta and its major branches. METHODS: Seventeen patients with a variety of aortic pathology were examined. Using a spiral CT-scanner a volumetric scan was made during injection of

  18. The use of Metrizamid in experimental renal angiography

    International Nuclear Information System (INIS)

    Pokorny, L.; Kelemen, J.

    1980-01-01

    A possible application of the non-ionizing contrast material metrizamid (Amipaque Vascularsup(R), Amipaquesup(R)) for renal angiography was experimentally investigated in dogs. 1.5, 3, 10 or 25 ml contrast medium was injected into one kidney. The animals were killed immediately, 3 hours, 24 hours, 7 or 28 days after angiography, and the kidneys were histologically investigated. In several cases the angiograms showed small alterations (transitory vasospasm, inhomogeneous spots on the nephrogram). Histology revealed in the initial period a homogeneous, pinkish, protein-like substance in the Bowman capsule and in the lumen of the tubuli, whereas later infiltrations by round cells and local accumulation of connective tissues were found. (L.E.)

  19. Indications for intra-arterial digital subtraction angiography (DSA) in vascular disease

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Friedmann, G.; Peters, P.E.; Moedder, U.

    1983-01-01

    Digital subtraction angiography (DSA), using a direct arterial route, diminishes the risk of the examination by reducing the contrast dose by about 75%, making the examination more rapid and making it less likely that catheters will have to be changed. At the same time superimposition is avoided, one of the advantages of selective catheterisation. In view of the low contrast dose, it is possible to carry out several examinations at one time and to use additional projections for intracranial and peripheral disease, thereby improving the diagnostic value of the examination. For certain problems, intra-arterial DSA is already able to replace conventional angiography. The small field size and poor spatial resolution still make conventional angiography necessary as the basic form of investigation in most other circumstances. (orig.) [de

  20. Magnetic resonance angiography of cerebral developmental venous anomalies: its role in differential diagnosis

    International Nuclear Information System (INIS)

    Ostertun, B.; Solymosi, L.

    1993-01-01

    CT, MRI and contrast angiography of 20 patients with 21 developmental venous anomalies (DVAs), so-called venous angiomas, were compared with magnetic resonance angiography employing a two-dimensional time-of-flight technique (2D-MRA). MRA was diagnostic in 17 DVAs, when both the primary 2D slices and the maximum-intensity-protection images were read. Contrast angiography still provides the best visualization of both DVA components: dilated medullary veins and transcerebral draining vein; however, it is an invasive procedure and delivers no information about brain parenchyma. We regard MRI as necessary in cases with a suspected DVA because of the high rate of association with cavernomas: 33% in this study. Acute neurological symptoms were caused by haemorrhage from an associated cavernoma and not from the DVA in 4 such cases. Thus MRA combined with MRI obviates angiography in most cases and offers a noninvasive diagnostic strategy adequate for DVAs. (orig.)

  1. Effects of video information on anxiety, stress and depression of patients undergoing coronary angiography

    International Nuclear Information System (INIS)

    Jamshidi, N.; Abbaszadeh, A.; Kalyani, M.N.

    2009-01-01

    Objective: Anxiety and stress are common in patients undergoing invasive procedures. Coronary angiography is a definitive diagnostic evaluation for coronary artery disease and valvular disease. It is necessary to give information to the patients in order to minimize levels of anxiety and stress to this invasive procedure. The aim of this study was to evaluate the effect of patients education by video on levels of anxiety, stress and depression of patients undergoing coronary angiography. Methodology: In a quasi-experimental, pretest-posttest design, 128 patients were randomly assigned to either control or experimental group. Control group received verbal routine education by nurses and experimental group received an informative video about coronary angiography procedure as well as pre and post angiography interventions. Using Depression, Anxiety, Stress Scale (DASS-21) levels of these variables were measured before and after education. Results: Seventy eight (60.9%) males and fifty (39.1%) females participated in the study. There was a statistically significant reduction in the Anxiety, stress and depression levels of experimental group after video information (P = .000). There was a statistically significant correlation between sex with anxiety (P = .000) and stress (P = .04). Conclusions: The use of patients education by informative video is a useful method for decreasing psychological parameters of patients undergoing coronary angiography procedure. Results of the study confirm the usefulness of video information prior to an Invasive angiography procedure. (author)

  2. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Angiography (MRA) Transcript Welcome to Radiology Info dot org Hello, I’m Dr. Elliot Fishman, a radiologist ... question you might have, visit Radiology Info dot org. Thank you for your time and for your ...

  3. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Disorders Video: The Basketball Game: An MRI Story Radiology and You Sponsored by Image/Video Gallery Your ... Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot org Hello, I’m Dr. Elliot ...

  4. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography ( ... posted: How to Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI ...

  5. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... mild sedative prior to the examination. For more information about Magnetic Resonance Angiography of MRA or any ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  6. Evaluation of protocolized angiography in performing the interventional procedure for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Jiang Jianqiang; Shi Haibin; Liu Sheng; Yang Zhengqiang; Zhou Chungao; Zhou Weizhong

    2010-01-01

    Objective: To assess the clinical value of protocolized angiography,including the superior mesenteric artery (SMA), the celiac artery and the common hepatic artery angiography, in detecting the atypical tumor feeding arteries of hepatocellular carcinoma (HCC) during transarterial chemoembolization (TACE) procedure. Methods: The clinical data of all patients who received the initial TACE for HCC during the period of January 2005-December 2009 were collected and were retrospectively analyzed. Both the angiograms and procedure reports were reviewed. According to the angiography protocols used in interventional procedure the patients were divided into two groups. Group A included 526 patients who received the protocolized angiography, including the SMA, the celiac artery and the common hepatic artery, while Group B composed of 850 patients who underwent the routine angiography of the common hepatic artery. For all patients in both groups the atypical tumor feeding arteries were searched for when the tumor staining was incomplete. The anatomic variations of tumor feeding arteries were classified and were statistically analyzed. Results: The detection rate of tumor supply from the branches of SMA, left gastric artery, phrenic artery and celiac artery was 14.1%, 6.7%, 4.6% and 0.5% respectively in group A, while it was 8.9%, 3.3%, 2.6% and 0% respectively in group B. Significant difference in all above four detection rates existed between two groups (P 0.05). Conclusion: Compared with the conventional common hepatic arteriography during TACE, the diagnostic protocolized angiography, including the SMA, the celiac artery and the common hepatic artery, can markedly improve the detection rates of atypical tumor feeders of HCC, such as the accessory hepatic artery, which means that the tumor will be occluded more completely and be controlled more promptly. (authors)

  7. Optical Coherence Tomography Angiography Features of Iris Racemose Hemangioma in 4 Cases.

    Science.gov (United States)

    Chien, Jason L; Sioufi, Kareem; Ferenczy, Sandor; Say, Emil Anthony T; Shields, Carol L

    2017-10-01

    Optical coherence tomography angiography (OCTA) allows visualization of iris racemose hemangioma course and its relation to the normal iris microvasculature. To describe OCTA features of iris racemose hemangioma. Descriptive, noncomparative case series at a tertiary referral center (Ocular Oncology Service of Wills Eye Hospital). Patients diagnosed with unilateral iris racemose hemangioma were included in the study. Features of iris racemose hemangioma on OCTA. Four eyes of 4 patients with unilateral iris racemose hemangioma were included in the study. Mean patient age was 50 years, all patients were white, and Snellen visual acuity was 20/20 in each case. All eyes had sectoral iris racemose hemangioma without associated iris or ciliary body solid tumor on clinical examination and ultrasound biomicroscopy. By anterior segment OCT, the racemose hemangioma was partially visualized in all cases. By OCTA, the hemangioma was clearly visualized as a uniform large-caliber vascular tortuous loop with intense flow characteristics superimposed over small-caliber radial iris vessels against a background of low-signal iris stroma. The vascular course on OCTA resembled a light bulb filament (filament sign), arising from the peripheral iris (base of light bulb) and forming a tortuous loop on reaching its peak (midfilament) near the pupil (n = 3) or midzonal iris (n = 1), before returning to the peripheral iris (base of light bulb). Intravenous fluorescein angiography performed in 1 eye depicted the iris hemangioma; however, small-caliber radial iris vessels were more distinct on OCTA than intravenous fluorescein angiography. Optical coherence tomography angiography is a noninvasive vascular imaging modality that clearly depicts the looping course of iris racemose hemangioma. Optical coherence tomography angiography depicted fine details of radial iris vessels, not distinct on intravenous fluorescein angiography.

  8. Ventilation-perfusion imaging and pulmonary angiography: changing pattern of use

    International Nuclear Information System (INIS)

    Teates, C.D.; Bezirdjian, D.R.; Bray, S.T.; Tegtmeyer, C.J.

    1981-01-01

    The hospital and departmental records of the University of Virginia Medical Center from 1976 to 1980 show an increasing frequency of ventilation studies relative to perfusion studies and a decrease in frequency of ventilation-perfusion diagnosis of pulmonary embolus. Pulmonary angiograms have increased from one per 68 nuclear studies to one per 14. A review of 70 patients with correlating angiography or autopsy shows that 89% of nuclear studies were accurate. We have revised our interpretation criteria and indications for pulmonary angiography

  9. Comparison of X-ray radiation exposure during digital subtraction angiography (DSA) and multislice CT angiography (CTA)

    International Nuclear Information System (INIS)

    Bai, Mei; Liu, Bin; Zheng, Junzheng

    2008-01-01

    Full text: Purpose: To compare radiation risk during digital subtraction angiography (DSA) and CT angiography (CTA). Materials and methods: Eighty patients randomly divided into two groups of 40 patients each, were evaluated for coronary atherosclerotic heart disease with 64-slice spiral CT angiography and DSA respectively. For CTA group we divided patients into two subgroups: regular mode and ECG modulation mode. Matix of thermoluminescent dosimeters (TLDs) were placed on patients' skin surface during each examination to access peak skin dose (PSD). A male ART phantom was equipped with TLDs in six different positions to assess achievable organ dose. Effective dose was calculated by commercially available computer programs. Results: For DSA, PSD was 64mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 11.07mGy, 5.87mGy, 1.42mGy, 2.11mGy, 6.76mGy and 0.001mGy respectively, and effective dose was 4mSv. For regular mode CTA, PSD was 74.5mGy, and CTD vol was 37.9mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 58mGy, 64.2mGy, 6.6mGy, 9.9mGy, 2.7mGy, 0.072mGy respectively, and effective dose was 16mSv. For ECG modulation mode, PSD was 50.9mGy, and CTD vol was 26.3mGy. Conclusion: According to measured PSD value, deterministic radiation risk for regular mode CTA was little higher than DSA. However for stochastic radiation risk which can be indicated by organ dose and effective dose, regular mode CTA was much higher than DSA. Comparing with regular mode, ECG modulation mode can effectively reduce both stochastic and deterministic radiation risk. (author)

  10. Understanding the basic concepts of CO2 angiography

    Science.gov (United States)

    Zannoli, Romano; Bianchini, David; Rossi, Pier Luca; Caridi, James G.; Corazza, Ivan

    2016-11-01

    The diagnostic quality of carbon dioxide angiography depends both on optimal setting of radiological aspects (X-ray emission and image post-processing) and on the mechanical behavior of the injected gas bubbles. The gas behavior differs in large cavities (d > 12 mm), medium sized vessels (d > 6 mm), and small diameter vessels (d rules governing the phenomenon in the particular situation. In most cases, it is impossible to fill a vessel completely with gas, and to obtain an adequate angiogram, the gas volume and injection pressure must be properly selected, patient's position must be adjusted and radiological image optimization algorithms, like Digital Subtraction Angiography (DSA) and stacking, must be applied. In this optimization process, the cultural and practical intervention of a medical physicist is fundamental. Obtaining a good quality CO2 angiogram is not only a matter of medical operator experience or radiological system performance, but involves matching a wide knowledge of medical physics to particular pathophysiological conditions and to unusual measurement tests. Most medical physicists are used to dealing mainly with radiological problems, and other physical aspects are considered beyond their interest. In CO2 angiography, non-radiological aspects strongly interfere with radiological issues and an optimal result can only be obtained by tackling the two simultaneously.

  11. Change of anxiety in patients undergoing coronary angiography

    International Nuclear Information System (INIS)

    Huang Zuo; Wu Zonggui; Wang Yongmei

    2004-01-01

    Objective: To investigate the change of anxiety in patients undergoing coronary angiography. Methods: The Spielberger State-Trait Anxiety Inventory was carried out in hundred and forty five patients, 104 men, 41 women, mean age (63 ± 9) years, before and after the coronary angiography procedure respectively. Results: The state anxiety score after the procedure was significantly decreased from 35.8 ± 10.2 to 31.7 ± 9.9 (P<0.01). The trait anxiety score after the procedure was slighytly lowered from 35.7 ± 8.8 to 34.4 ± 9.4 (P=0.019). Sub- group analysis showed that the state anxiety score in 55 patients with normal coronary artery was markedly decreased from 37.5 ± 10.5 to 28.8 ± 8.2 (P<0.01) while the state anxiety score in 90 patients with abnormal coronary artery was unchanged. The score in those patients with abnormal coronary artery was much higher than that of patients with normal coronary artery (33.5 ± 10.4 vs 28.8 ± 8.2, P<0.01). The trait anxiety scores in both group were not changed. Conclusion: Good news about normal coronary artery after angiography may reduce the anxiety in patients suspected of coronary heart disease. (authors)

  12. Ultra-wide-field angiography improves the detection and classification of diabetic retinopathy.

    Science.gov (United States)

    Wessel, Matthew M; Aaker, Grant D; Parlitsis, George; Cho, Minhee; D'Amico, Donald J; Kiss, Szilárd

    2012-04-01

    To evaluate patients with diabetic retinopathy using ultra-wide-field fluorescein angiography and to compare the visualized retinal pathology with that seen on an overly of conventional 7 standard field (7SF) imaging. Two hundred and eighteen eyes of 118 diabetic patients who underwent diagnostic fluorescein angiography using the Optos Optomap Panoramic 200A imaging system were included. The visualized area of the retina, retinal nonperfusion, retinal neovascularization, and panretinal photocoagulation were quantified by two independent masked graders. The respective areas identified on the ultra-wide-field fluorescein angiography image were compared with an overly of a modified 7SF image as outlined in the Early Treatment Diabetic Retinopathy Study. Ultra-wide-field fluorescein angiograms imaging, on average, demonstrated 3.2 times more total retinal surface area than 7SF. When compared with 7SF, ultra-wide-field fluorescein angiography showed 3.9 times more nonperfusion (P diabetic retinopathy. Improved retinal visualization may alter the classification of diabetic retinopathy and may therefore influence follow-up and treatment of these patients.

  13. Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function.

    Science.gov (United States)

    Park, Sung Yoon; Kim, Chan Kyo; Kim, EunJu; Park, Byung Kwan

    2015-02-01

    To investigate the feasibility of noncontrast-enhanced MR angiography (NC-MRA) using the repetitive artery and venous labelling (RAVEL) technique to evaluate renal arteries compared to contrast-enhanced MR angiography (CE-MRA). Twenty-five subjects with normal renal function underwent NC-MRA using a RAVEL technique and CE-MRA at 3 T. Two independent readers analysed the MRA images. Image quality, number of renal arteries, presence or absence of an early branching vessel, and diameter of the main renal arteries were evaluated. The overall image quality of NC-MRA was fair or greater in 88% of right and 92% of left renal arteries, while it was 96% in both sides with CE-MRA. On NC-MRA, the number of renal arteries in all subjects was perfectly predicted by both readers. Sensitivity and specificity for predicting early branching vessels were 82% and 100% for reader 1 and 82% and 95% for reader 2. Inter-modality agreement for comparing the diameters of main renal arteries was good or excellent at all segments for both readers. Inter-reader agreement was moderate or good at all segments except at the right distal segment on NC-MRA. NC-MRA with the RAVEL technique at 3 T may have comparable diagnostic feasibility for evaluating renal arteries compared to CE-MRA. • Accurate pre-treatment evaluation of renal artery anatomy helps clinical decision-making. • NC-MRA using RAVEL offers acceptable imaging quality for renal artery evaluation. • The 3 T RAVEL technique provides excellent diagnostic performance for renal artery evaluation. • The 3 T RAVEL technique may be an alternative to contrast-enhanced MRA.

  14. Angiorressonância magnética do crânio: revisão de 100 casos Magnetic resonance angiography of the brain: review of 100 cases

    Directory of Open Access Journals (Sweden)

    Leonardo Portugal Guimarães Amaral

    2004-06-01

    Full Text Available Neste trabalho foram analisados, retrospectivamente, os exames de 100 pacientes que se submeteram a angiografia por ressonância magnética (angio-RM do crânio com diferentes indicações clínicas. Os objetivos deste trabalho foram discutir as vantagens e desvantagens da técnica 3D TOF em exames de angio-RM cerebral e verificar as principais indicações de angio-RM na avaliação das lesões vasculares intracranianas e a freqüência dos principais achados nestes exames. As principais indicações para a realização de angio-RM neste trabalho foram cefaléia (n = 29, acidente vascular encefálico (n = 14 e ataque isquêmico transitório (n = 11. Em 11 casos não havia indicação clínica e os demais tiveram indicações diversas. Cinqüenta e dois por cento dos exames apresentaram alguma alteração. Os principais achados foram estenose vascular (n = 30, aneurisma (n = 10, variações anatômicas (n = 6, malformações vasculares (n = 4 e trombose dos seios durais (n = 2. A técnica 3D TOF, única utilizada neste trabalho, mostrou-se eficiente na maioria dos casos, com um tempo relativamente curto para sua aquisição. Como desvantagem, não se mostra eficaz para cobrir grandes volumes.In this study we reviewed the scans of 100 patients submitted to magnetic resonance angiography (MR angiography of the brain for different clinical indications. The objectives of the study were to discuss the advantages and disadvantages of the 3D TOF in cerebral MR angiography, to review the main indications of MR angiography in the evaluation of intracranial vascular lesions, and to assess the frequency of the most important findings. The main indications for MR angiography were headache (n = 29, stroke (n = 14, transient ischemic attack (n = 11 and other causes (n = 35. In 11 patients the clinical indication could not be recovered from the patients records. Fifty two percent of the exams showed abnormalities. The main findings were vascular stenosis (n

  15. Optical Coherence Tomography Angiography in Retinal Diseases.

    Science.gov (United States)

    Chalam, K V; Sambhav, Kumar

    2016-01-01

    Optical coherence tomography angiography (OCTA) is a new, non-invasive imaging system that generates volumetric data of retinal and choroidal layers. It has the ability to show both structural and blood flow information. Split-spectrum amplitude-decorrelation angiography (SSADA) algorithm (a vital component of OCTA software) helps to decrease the signal to noise ratio of flow detection thus enhancing visualization of retinal vasculature using motion contrast. Published studies describe potential efficacy for OCTA in the evaluation of common ophthalmologic diseases such as diabetic retinopathy, age related macular degeneration (AMD), retinal vascular occlusions and sickle cell disease. OCTA provides a detailed view of the retinal vasculature, which allows accurate delineation of microvascular abnormalities in diabetic eyes and vascular occlusions. It helps quantify vascular compromise depending upon the severity of diabetic retinopathy. OCTA can also elucidate the presence of choroidal neovascularization (CNV) in wet AMD. In this paper, we review the knowledge, available in English language publications regarding OCTA, and compare it with the conventional angiographic standard, fluorescein angiography (FA). Finally, we summarize its potential applications to retinal vascular diseases. Its current limitations include a relatively small field of view, inability to show leakage, and tendency for image artifacts. Further larger studies will define OCTA's utility in clinical settings and establish if the technology may offer a non-invasive option of visualizing the retinal vasculature, enabling us to decrease morbidity through early detection and intervention in retinal diseases.

  16. Deep neural network-based computer-assisted detection of cerebral aneurysms in MR angiography.

    Science.gov (United States)

    Nakao, Takahiro; Hanaoka, Shouhei; Nomura, Yukihiro; Sato, Issei; Nemoto, Mitsutaka; Miki, Soichiro; Maeda, Eriko; Yoshikawa, Takeharu; Hayashi, Naoto; Abe, Osamu

    2018-04-01

    The usefulness of computer-assisted detection (CAD) for detecting cerebral aneurysms has been reported; therefore, the improved performance of CAD will help to detect cerebral aneurysms. To develop a CAD system for intracranial aneurysms on unenhanced magnetic resonance angiography (MRA) images based on a deep convolutional neural network (CNN) and a maximum intensity projection (MIP) algorithm, and to demonstrate the usefulness of the system by training and evaluating it using a large dataset. Retrospective study. There were 450 cases with intracranial aneurysms. The diagnoses of brain aneurysms were made on the basis of MRA, which was performed as part of a brain screening program. Noncontrast-enhanced 3D time-of-flight (TOF) MRA on 3T MR scanners. In our CAD, we used a CNN classifier that predicts whether each voxel is inside or outside aneurysms by inputting MIP images generated from a volume of interest (VOI) around the voxel. The CNN was trained in advance using manually inputted labels. We evaluated our method using 450 cases with intracranial aneurysms, 300 of which were used for training, 50 for parameter tuning, and 100 for the final evaluation. Free-response receiver operating characteristic (FROC) analysis. Our CAD system detected 94.2% (98/104) of aneurysms with 2.9 false positives per case (FPs/case). At a sensitivity of 70%, the number of FPs/case was 0.26. We showed that the combination of a CNN and an MIP algorithm is useful for the detection of intracranial aneurysms. 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:948-953. © 2017 International Society for Magnetic Resonance in Medicine.

  17. The evaluation of three-dimensional dynamic contrast enhanced MR angiography in portal hypertension

    International Nuclear Information System (INIS)

    Wu Zhuo; Liang Biling; Liu Qingyu; Zhong Jinglian; Ye Ruixin; Ling Yunbiao; Ou Qingjia

    2006-01-01

    Objective: To evaluate the techniques of three-dimensional dynamic contrast enhanced MR angiography (3D DCE MRA)with normative timing of sequences, enhancive 3D slab thickness and subtraction in portosystemic collaterals. Methods: Before April 2003, 12 patients were performed with 75-90 mm of 3D slab thickness and 3-5 repeated sequences estimated by breath, after April 2003, 18 patients were performed with 150-180 mm of 3D slab thickness and 5 normative repeated sequences respectively at 0, 20, 40, 60 and 90 s. After subtracting selective arterial phase images from subsequent portal venous phase images, two radiologists assessed visualization of portal collaterals independently with a four - point scale for ranking of image quality in maximum intensity projection (MIP) images with and without subtraction. Results: Average scores for image quality in visualization of the portal vein with subtraction were significantly depressed compared with the scores without subtraction (2.53±0.49 versus 2.74±0.31, P<0.05). However, subtraction three dimension-maximum intensity projection (3D-MIP) gave superior visualization of portal collaterals compared with non-subtraction 3D-MIP(2.58±0.30 versus 1.63±0.50). A statistically significant difference (P<0.01) was found between the two groups of esophageal varices. Most of portosystemic shunts demonstrated in the same time as the portal vein at about 20s, but some of collaterals demonstrated in delay time. Conclusion: Subtraction 3D-MIP demonstrates portosystemic collaterals more clearly than non-subtraction; normative timing of sequences ensure against omitting varices displayed late, 3 D slab thickness provides details about paraumbilical vein and retroperitoneal collaterals. (authors)

  18. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive test ... of the major blood vessels throughout your body. It may be performed with or without contrast material ...

  19. A general protocol of ultra-high resolution MR angiography to image the cerebro-vasculature in 6 different rats strains at high field.

    Science.gov (United States)

    Pastor, Géraldine; Jiménez-González, María; Plaza-García, Sandra; Beraza, Marta; Padro, Daniel; Ramos-Cabrer, Pedro; Reese, Torsten

    2017-09-01

    Differences in the cerebro-vasculature among strains as well as individual animals might explain variability in animal models and thus, a non-invasive method tailored to image cerebral vessel of interest with high signal to noise ratio is required. Experimentally, we describe a new general protocol of three-dimensional time-of-flight magnetic resonance angiography to visualize non-invasively the cerebral vasculature in 6 different rat strains. Flow compensated angiograms of Sprague Dawley, Wistar Kyoto, Lister Hooded, Long Evans, Fisher 344 and Spontaneous Hypertensive Rat strains were obtained without the use of contrast agents. At 11.7T using a repetition time of 60ms, an isotropic resolution of up to 62μm was achieved; total imaging time was 98min for a 3D data set. The visualization of the cerebral arteries was improved by removing extra-cranial vessels prior to the calculation of maximum intensity projection to obtain the angiograms. Ultimately, we demonstrate that the newly implemented method is also suitable to obtain angiograms following middle cerebral artery occlusion, despite the presence of intense vasogenic edema 24h after reperfusion. The careful selection of the excitation profile and repetition time at a higher static magnetic field allowed an increase in spatial resolution to reliably detect of the hypothalamic artery, the anterior choroidal artery as well as arterial branches of the peri-amygdoidal complex and the optical nerve in six different rat strains. MR angiography without contrast agent can be utilized to study cerebro-vascular abnormalities in various animal models. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Clinical application of magnetic resonance coronary angiography

    International Nuclear Information System (INIS)

    Murakami, Akihiko; Onoe, Teruyuki; Kodera, Akifumi; Ohtsuki, Tetsuya; Shiomi, Akio; Ida, Masaaki; Sawada, Takahisa

    1999-01-01

    We performed the magnetic resonance coronary angiography (MRCA) in the cases which underwent coronary angiography (CAG) and obtained images were compared. Lesion with significant constriction more than 75% on CAG were determined as abnormal findings on MRCA, however, lesions with about 50% constriction were as the normal findings. On the assessment of the re-constriction after PTCA, the changes in signal were found in about half of cases. This may come from the contribution of flexion lesions, the difficulty to assess moderate constriction after PTCA, etc. For the anomalous aortic origin of coronary artery, peripheral large vessels could be simultaneously imaged by MRCA and be also assessed among their clear spatial relationship. Although MRCA has some problems on the assessment for flexion or moderate constriction, these results suggested that MRCA is useful to clinical application as the non-invasive examination. (K.H.)