WorldWideScience

Sample records for aneurysm phantoms psaps

  1. 911 Master PSAP Registry

    Data.gov (United States)

    Federal Communications Commission — Updated as of 5Oct2017. The Registry lists PSAPs by an FCC assigned identification number, PSAP Name, State, County, City, and provides information on any type of...

  2. Experimental study on blood flow patterns through the phantoms of the intracranial arterial aneurysms using color Doppler imaging

    International Nuclear Information System (INIS)

    Chung, Tae Sub; Jeong, Eun Kee; Rhim, Yoon Chul; Kim, Sung Bin; Lee, Dong Hoon; Kim, Dae In

    1994-01-01

    The occurrence, growth, thrombosis, and rupture of intracranial saccular aneurysms can be directly related to the effect of hemodynamic forces. We developed the phantom flow models and compared with the computer simulation program to analyse the flow pattern and hemodynamics that might be responsible for the intracranial arterial aneurysms. We designed the arterial phantoms of three major sites of intracranial arterial aneurysm ; 1) basilar artery tip, 2) internal carotid artery bifurcation, 3) curved area of internal carotid artery. Flow patterns in the aneurysmal portion of phantoms were evaluated with color Doppler system on the connection with automatic closed type of circulation system. Then, we compared the results with computer simulation. The hemodynamic characteristics of the phantoms were identical with those obtained by computerisation's. Three distinct zones of flow were identified by color Doppler studies on the aneurysm of the curved area of an internal carotid artery : 1) an inflow zone entering the aneurysm at the distal aspect of its orifice, 2) an outflow zone exiting the aneurysm at the proximal aspect of its orifice, 3) a central slow vortex.However, the phantoms of basilar artery tip and artery bifurcation showed a direct inflow stream at the dome of an aneurysm. Flow dynamics in the various phantoms of the aneurysms can be successfully evaluated with color Doppler imaging, and were consistent with those predicted by computer simulations

  3. Turnover in intracranial aneurysm phantoms: its relation to neck size

    International Nuclear Information System (INIS)

    Chung, Tae Sub; Lee, Young Jun; Rhim, Yoon Chul

    2003-01-01

    To evaluate the physiologic background of aneurysms poorly visualized during 3D-TOF MRA, contrast-enhanced MRA (CEMRA) and DSA due to hemodynamic isolation. Using handmade elastic silicon phantoms to represent terminal basilar tip aneurysms, 3D-TOF MRA, CEMRA and DSA were used to determine blood turnover. Aneurysmal neck size was 2 mm and 10 mm, and the use of a pulsatile pump also helped recreate human physiologic parameters. We compared the results with those of computational fluid dynamics. DSA images of the narrow-necked aneurysm showed that a small volume of contrast medium washed into it during the systolic phase. As the width of its neck increased, the turnover volume of fragments of contrast bolus also increased. At CEMRA, the broad-necked aneurysm was visualized as the main bolus of Gd-DTPA passed through it, and at delayed CEMRA, the narrow-necked aneurysm was visualized faintly after the passage of bolus Gd-DTPA. The results correlated closely with those of 3D-TOF MRA and computational fluid dynamics. The visualization of intracranial aneurysms at 3D-TOF MRA, CEMRA and DSA was greatly dependent upon blood turnover, which varied according to aneurysmal neck size. A narrow-necked aneurysm might be missed at 3D-TOF MRA, CEMRA and DSA due to hemodynamic isolation

  4. Phantom-based experimental validation of computational fluid dynamics simulations on cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Sun Qi; Groth, Alexandra; Bertram, Matthias; Waechter, Irina; Bruijns, Tom; Hermans, Roel; Aach, Til [Philips Research Europe, Weisshausstrasse 2, 52066 Aachen (Germany) and Institute of Imaging and Computer Vision, RWTH Aachen University, Sommerfeldstrasse 24, 52074 Aachen (Germany); Philips Research Europe, Weisshausstrasse 2, 52066 Aachen (Germany); Philips Healthcare, X-Ray Pre-Development, Veenpluis 4-6, 5684PC Best (Netherlands); Institute of Imaging and Computer Vision, RWTH Aachen University, Sommerfeldstrasse 24, 52074 Aachen (Germany)

    2010-09-15

    Purpose: Recently, image-based computational fluid dynamics (CFD) simulation has been applied to investigate the hemodynamics inside human cerebral aneurysms. The knowledge of the computed three-dimensional flow fields is used for clinical risk assessment and treatment decision making. However, the reliability of the application specific CFD results has not been thoroughly validated yet. Methods: In this work, by exploiting a phantom aneurysm model, the authors therefore aim to prove the reliability of the CFD results obtained from simulations with sufficiently accurate input boundary conditions. To confirm the correlation between the CFD results and the reality, virtual angiograms are generated by the simulation pipeline and are quantitatively compared to the experimentally acquired angiograms. In addition, a parametric study has been carried out to systematically investigate the influence of the input parameters associated with the current measuring techniques on the flow patterns. Results: Qualitative and quantitative evaluations demonstrate good agreement between the simulated and the real flow dynamics. Discrepancies of less than 15% are found for the relative root mean square errors of time intensity curve comparisons from each selected characteristic position. The investigated input parameters show different influences on the simulation results, indicating the desired accuracy in the measurements. Conclusions: This study provides a comprehensive validation method of CFD simulation for reproducing the real flow field in the cerebral aneurysm phantom under well controlled conditions. The reliability of the CFD is well confirmed. Through the parametric study, it is possible to assess the degree of validity of the associated CFD model based on the parameter values and their estimated accuracy range.

  5. Phantom-based experimental validation of computational fluid dynamics simulations on cerebral aneurysms

    International Nuclear Information System (INIS)

    Sun Qi; Groth, Alexandra; Bertram, Matthias; Waechter, Irina; Bruijns, Tom; Hermans, Roel; Aach, Til

    2010-01-01

    Purpose: Recently, image-based computational fluid dynamics (CFD) simulation has been applied to investigate the hemodynamics inside human cerebral aneurysms. The knowledge of the computed three-dimensional flow fields is used for clinical risk assessment and treatment decision making. However, the reliability of the application specific CFD results has not been thoroughly validated yet. Methods: In this work, by exploiting a phantom aneurysm model, the authors therefore aim to prove the reliability of the CFD results obtained from simulations with sufficiently accurate input boundary conditions. To confirm the correlation between the CFD results and the reality, virtual angiograms are generated by the simulation pipeline and are quantitatively compared to the experimentally acquired angiograms. In addition, a parametric study has been carried out to systematically investigate the influence of the input parameters associated with the current measuring techniques on the flow patterns. Results: Qualitative and quantitative evaluations demonstrate good agreement between the simulated and the real flow dynamics. Discrepancies of less than 15% are found for the relative root mean square errors of time intensity curve comparisons from each selected characteristic position. The investigated input parameters show different influences on the simulation results, indicating the desired accuracy in the measurements. Conclusions: This study provides a comprehensive validation method of CFD simulation for reproducing the real flow field in the cerebral aneurysm phantom under well controlled conditions. The reliability of the CFD is well confirmed. Through the parametric study, it is possible to assess the degree of validity of the associated CFD model based on the parameter values and their estimated accuracy range.

  6. HSIP E911 Public Safety Answering Point (PSAP)

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — 911 Public Safety Answering Point (PSAP) service area boundaries in New Mexico According to the National Emergency Number Association (NENA), a Public Safety...

  7. Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models

    Directory of Open Access Journals (Sweden)

    Anderson Chun On Tsang

    2015-04-01

    Full Text Available Purpose: The aim of this study was to validate a computational fluid dynamics (CFD simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. Methods: Computational and physical models of patient-specific bifurcation and sidewall aneurysms were constructed from computed tomography angiography with use of stereolithography, a three-dimensional printing technology. Flow dynamics parameters before and after flow-diverter treatment were measured with pulse-wave and color Doppler ultrasonography, and then compared with CFD simulations. Results: CFD simulations showed drastic flow reduction after flow-diverter treatment in both aneurysms. The mean volume flow rate decreased by 90% and 85% for the bifurcation aneurysm and the side-wall aneurysm, respectively. Velocity contour plots from computer simulations before and after flow diversion closely resembled the patterns obtained by color Doppler ultrasonography. Conclusion: The CFD estimation of flow reduction in aneurysms treated with a flow-diverting stent was verified by Doppler ultrasonography in patient-specific phantom models of bifurcation and side-wall aneurysms. The combination of CFD and ultrasonography may constitute a feasible and reliable technique in studying the treatment of intracranial aneurysms with flow-diverting stents.

  8. Active and Passive Supplier Assessment Program (ASAP & PSAP) WWW Sites http://nepp.nasa.gov/imd/asap http://nepp.nasa.gov/imd/psap

    Science.gov (United States)

    Brusse, Jay

    2000-01-01

    The Active and Passive Supplier Assessment Programs (ASAP and PSAP) WWW Sites provide general information to the electronic parts community regarding the availability of electronic parts. They also provide information to NASA regarding modifications to commonly used procurement specifications and test methods. The ASAP and PSAP www sites are ongoing resources produced by Code 562 in support of the NASA HQ funded NASA Electronic Parts and Packaging (NEPP) Program. These WWW sites do not provide information pertaining to patented or proprietary information. All of the information contained in these www sites is available through various other public domain resources such as US Military Qualified Producers Listings (QPLs) and Qualified Manufacturer Listings (QMLs) and industry working groups such as the Electronics Industry Alliance (EIA) and the Space Parts Working Group (SPWG).

  9. A multimodality vascular imaging phantom of an abdominal aortic aneurysm with a visible thrombus

    Energy Technology Data Exchange (ETDEWEB)

    Allard, Louise; Chayer, Boris; Qin Zhao [Laboratory of Biorheology and Medical Ultrasonics, Research Center, University of Montreal Hospital (CRCHUM), Quebec H2L 2W5 (Canada); Soulez, Gilles [Department of Radiology, University of Montreal Hospital (CHUM), Quebec H2L 2M1 (Canada); Department of Radiology, Radio-Oncology and Nuclear Medicine, University of Montreal, Quebec H3T 1J4 (Canada); Institute of Biomedical Engineering, University of Montreal, Quebec H3T 1J4 (Canada); Roy, David [Institute of Biomedical Engineering, University of Montreal, Quebec H3T 1J4 (Canada); Cloutier, Guy [Laboratory of Biorheology and Medical Ultrasonics, Research Center, University of Montreal Hospital (CRCHUM), Quebec H2L 2W5 (Canada); Department of Radiology, Radio-Oncology and Nuclear Medicine, University of Montreal, Quebec H3T 1J4 (Canada); Institute of Biomedical Engineering, University of Montreal, Quebec H3T 1J4 (Canada)

    2013-06-15

    Purpose: With the continuous development of new stent grafts and implantation techniques, it has now become technically feasible to treat abdominal aortic aneurysms (AAA) with challenging anatomy using endovascular repair with standard, fenestrated, or branched stent-grafts. In vitro experimentations are very useful to improve stent-graft design and conformability or imaging guidance for stent-graft delivery or follow-up. Vascular replicas also help to better understand the limitation of endovascular approaches in challenging anatomy and possibly improve surgical planning or training by practicing high risk clinical procedures in the laboratory to improve outcomes in the operating room. Most AAA phantoms available have a very basic anatomy, which is not representative of the clinical reality. This paper presents a method of fabrication of a realistic AAA phantom with a visible thrombus, as well as some mechanical properties characterizing such phantom. Methods: A realistic AAA geometry replica of a real patient anatomy taken from a multidetector computed tomography (CT) scan was manufactured. To demonstrate the multimodality imaging capability of this new phantom with a thrombus visible in magnetic resonance (MR) angiography, CT angiography (CTA), digital subtraction angiography (DSA), and ultrasound, image acquisitions with all these modalities were performed by using standard clinical protocols. Potential use of this phantom for stent deployment was also tested. A rheometer allowed defining hyperelastic and viscoelastic properties of phantom materials. Results: MR imaging measurements of SNR and CNR values on T1 and T2-weighted sequences and MR angiography indicated reasonable agreement with published values of AAA thrombus and abdominal components in vivo. X-ray absorption also lay within normal ranges of AAA patients and was representative of findings observed on CTA, fluoroscopy, and DSA. Ultrasound propagation speeds for developed materials were also in

  10. A multimodality vascular imaging phantom of an abdominal aortic aneurysm with a visible thrombus

    International Nuclear Information System (INIS)

    Allard, Louise; Chayer, Boris; Qin Zhao; Soulez, Gilles; Roy, David; Cloutier, Guy

    2013-01-01

    Purpose: With the continuous development of new stent grafts and implantation techniques, it has now become technically feasible to treat abdominal aortic aneurysms (AAA) with challenging anatomy using endovascular repair with standard, fenestrated, or branched stent-grafts. In vitro experimentations are very useful to improve stent-graft design and conformability or imaging guidance for stent-graft delivery or follow-up. Vascular replicas also help to better understand the limitation of endovascular approaches in challenging anatomy and possibly improve surgical planning or training by practicing high risk clinical procedures in the laboratory to improve outcomes in the operating room. Most AAA phantoms available have a very basic anatomy, which is not representative of the clinical reality. This paper presents a method of fabrication of a realistic AAA phantom with a visible thrombus, as well as some mechanical properties characterizing such phantom. Methods: A realistic AAA geometry replica of a real patient anatomy taken from a multidetector computed tomography (CT) scan was manufactured. To demonstrate the multimodality imaging capability of this new phantom with a thrombus visible in magnetic resonance (MR) angiography, CT angiography (CTA), digital subtraction angiography (DSA), and ultrasound, image acquisitions with all these modalities were performed by using standard clinical protocols. Potential use of this phantom for stent deployment was also tested. A rheometer allowed defining hyperelastic and viscoelastic properties of phantom materials. Results: MR imaging measurements of SNR and CNR values on T1 and T2-weighted sequences and MR angiography indicated reasonable agreement with published values of AAA thrombus and abdominal components in vivo. X-ray absorption also lay within normal ranges of AAA patients and was representative of findings observed on CTA, fluoroscopy, and DSA. Ultrasound propagation speeds for developed materials were also in

  11. Development of an artifact-free aneurysm clip

    Directory of Open Access Journals (Sweden)

    Brack Alexander

    2016-09-01

    Full Text Available For the treatment of intracranial aneurysms with aneurysm clips, usually a follow-up inspection in MRI is required. To avoid any artifacts, which can make a proper diagnosis difficult, a new approach for the manufacturing of an aneurysm clip entirely made from fiber-reinforced plastics has been developed. In this paper the concept for the design of the clip, the development of a new manufacturing technology for the fiber-reinforced components as well as first results from the examination of the components in phantom MRI testing is shown.

  12. 3D printed abdominal aortic aneurysm phantom for image guided surgical planning with a patient specific fenestrated endovascular graft system

    Science.gov (United States)

    Meess, Karen M.; Izzo, Richard L.; Dryjski, Maciej L.; Curl, Richard E.; Harris, Linda M.; Springer, Michael; Siddiqui, Adnan H.; Rudin, Stephen; Ionita, Ciprian N.

    2017-03-01

    Following new trends in precision medicine, Juxatarenal Abdominal Aortic Aneurysm (JAAA) treatment has been enabled by using patient-specific fenestrated endovascular grafts. The X-ray guided procedure requires precise orientation of multiple modular endografts within the arteries confirmed via radiopaque markers. Patient-specific 3D printed phantoms could familiarize physicians with complex procedures and new devices in a risk-free simulation environment to avoid periprocedural complications and improve training. Using the Vascular Modeling Toolkit (VMTK), 3D Data from a CTA imaging of a patient scheduled for Fenestrated EndoVascular Aortic Repair (FEVAR) was segmented to isolate the aortic lumen, thrombus, and calcifications. A stereolithographic mesh (STL) was generated and then modified in Autodesk MeshMixer for fabrication via a Stratasys Eden 260 printer in a flexible photopolymer to simulate arterial compliance. Fluoroscopic guided simulation of the patient-specific FEVAR procedure was performed by interventionists using all demonstration endografts and accessory devices. Analysis compared treatment strategy between the planned procedure, the simulation procedure, and the patient procedure using a derived scoring scheme. Results: With training on the patient-specific 3D printed AAA phantom, the clinical team optimized their procedural strategy. Anatomical landmarks and all devices were visible under x-ray during the simulation mimicking the clinical environment. The actual patient procedure went without complications. Conclusions: With advances in 3D printing, fabrication of patient specific AAA phantoms is possible. Simulation with 3D printed phantoms shows potential to inform clinical interventional procedures in addition to CTA diagnostic imaging.

  13. PIV-measured versus CFD-predicted flow dynamics in anatomically realistic cerebral aneurysm models.

    Science.gov (United States)

    Ford, Matthew D; Nikolov, Hristo N; Milner, Jaques S; Lownie, Stephen P; Demont, Edwin M; Kalata, Wojciech; Loth, Francis; Holdsworth, David W; Steinman, David A

    2008-04-01

    Computational fluid dynamics (CFD) modeling of nominally patient-specific cerebral aneurysms is increasingly being used as a research tool to further understand the development, prognosis, and treatment of brain aneurysms. We have previously developed virtual angiography to indirectly validate CFD-predicted gross flow dynamics against the routinely acquired digital subtraction angiograms. Toward a more direct validation, here we compare detailed, CFD-predicted velocity fields against those measured using particle imaging velocimetry (PIV). Two anatomically realistic flow-through phantoms, one a giant internal carotid artery (ICA) aneurysm and the other a basilar artery (BA) tip aneurysm, were constructed of a clear silicone elastomer. The phantoms were placed within a computer-controlled flow loop, programed with representative flow rate waveforms. PIV images were collected on several anterior-posterior (AP) and lateral (LAT) planes. CFD simulations were then carried out using a well-validated, in-house solver, based on micro-CT reconstructions of the geometries of the flow-through phantoms and inlet/outlet boundary conditions derived from flow rates measured during the PIV experiments. PIV and CFD results from the central AP plane of the ICA aneurysm showed a large stable vortex throughout the cardiac cycle. Complex vortex dynamics, captured by PIV and CFD, persisted throughout the cardiac cycle on the central LAT plane. Velocity vector fields showed good overall agreement. For the BA, aneurysm agreement was more compelling, with both PIV and CFD similarly resolving the dynamics of counter-rotating vortices on both AP and LAT planes. Despite the imposition of periodic flow boundary conditions for the CFD simulations, cycle-to-cycle fluctuations were evident in the BA aneurysm simulations, which agreed well, in terms of both amplitudes and spatial distributions, with cycle-to-cycle fluctuations measured by PIV in the same geometry. The overall good agreement

  14. Flow and wall shear stress characterization after endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model.

    Science.gov (United States)

    Boersen, Johannes T; Groot Jebbink, Erik; Versluis, Michel; Slump, Cornelis H; Ku, David N; de Vries, Jean-Paul P M; Reijnen, Michel M P J

    2017-12-01

    Endovascular aneurysm repair (EVAR) with a modular endograft has become the preferred treatment for abdominal aortic aneurysms. A novel concept is endovascular aneurysm sealing (EVAS), consisting of dual endoframes surrounded by polymer-filled endobags. This dual-lumen configuration is different from a bifurcation with a tapered trajectory of the flow lumen into the two limbs and may induce unfavorable flow conditions. These include low and oscillatory wall shear stress (WSS), linked to atherosclerosis, and high shear rates that may result in thrombosis. An in vitro study was performed to assess the impact of EVAR and EVAS on flow patterns and WSS. Four abdominal aortic aneurysm phantoms were constructed, including three stented models, to study the influence of the flow divider on flow (Endurant [Medtronic, Minneapolis, Minn], AFX [Endologix, Irvine, Calif], and Nellix [Endologix]). Experimental models were tested under physiologic resting conditions, and flow was visualized with laser particle imaging velocimetry, quantified by shear rate, WSS, and oscillatory shear index (OSI) in the suprarenal aorta, renal artery (RA), and common iliac artery. WSS and OSI were comparable for all models in the suprarenal aorta. The RA flow profile in the EVAR models was comparable to the control, but a region of lower WSS was observed on the caudal wall compared with the control. The EVAS model showed a stronger jet flow with a higher shear rate in some regions compared with the other models. Small regions of low WSS and high OSI were found near the distal end of all stents in the common iliac artery compared with the control. Maximum shear rates in each region of interest were well below the pathologic threshold for acute thrombosis. The different stent designs do not influence suprarenal flow. Lower WSS is observed in the caudal wall of the RA after EVAR and a higher shear rate after EVAS. All stented models have a small region of low WSS and high OSI near the distal outflow

  15. Abdominal aortic aneurysms: virtual imaging and analysis through a remote web server

    International Nuclear Information System (INIS)

    Neri, Emanuele; Bargellini, Irene; Vignali, Claudio; Bartolozzi, Carlo; Rieger, Michael; Jaschke, Werner; Giachetti, Andrea; Tuveri, Massimiliano

    2005-01-01

    The study describes the application of a web-based software in the planning of the endovascular treatment of abdominal aortic aneurysms (AAA). The software has been developed in the framework of a 2-year research project called Aneurysm QUAntification Through an Internet Collaborative System (AQUATICS); it allows to manage remotely Virtual Reality Modeling Language (VRML) models of the abdominal aorta, derived from multirow computed tomography angiography (CTA) data sets, and to obtain measurements of diameters, angles and centerline lengths. To test the reliability of measurements, two radiologists performed a detailed analysis of multiple 3D models generated from a synthetic phantom, mimicking an AAA. The system was tested on 30 patients with AAA; CTA data sets were mailed and the time required for segmentation and measurement were collected for each case. The Bland-Altman plot analysis showed that the mean intra- and inter-observer differences in measures on phantoms were clinically acceptable. The mean time required for segmentation was 1 h (range 45-120 min). The mean time required for measurements on the web was 7 min (range 4-11 min). The AQUATICS web server may provide a rapid, standardized and accurate tool for the evaluation of AAA prior to the endovascular treatment. (orig.)

  16. Comparative analysis for evaluating the traceability of interventional devices using blood vessel phantom models made of PVA-H or silicone.

    Science.gov (United States)

    Yu, Chang-Ho; Kwon, Tae-Kyu; Park, Chan Hee; Ohta, Makoto; Kim, Sung Hoon

    2015-01-01

    In this paper, we investigated the parameters with effective traceability to assess the mechanical properties of interventional devices. In our evaluation system, a box-shaped poly (vinyl alcohol) hydrogel (PVA-H) and silicone were prepared with realistic geometry, and the measurement and evaluation of traceability were carried out on devices using load hand force. The phantom models had a total of five curve pathways to reach the aneurysm sac. Traceability depends on the performance of the interventional devices in order to pass through the curved part of the model simulation track. The traceability of the guide wire was found to be much better than that of the balloon and stent loading catheter, as it reached the aneurysm sac in both phantom models. Observation using the video record is another advantage of our system, because the high transparency of the materials with silicone and PVA-H can allow visualization of the inside of an artery.

  17. Brain aneurysm repair

    Science.gov (United States)

    ... aneurysm repair; Dissecting aneurysm repair; Endovascular aneurysm repair - brain; Subarachnoid hemorrhage - aneurysm ... Your scalp, skull, and the coverings of the brain are opened. A metal clip is placed at ...

  18. The intracranial aneurysm: cost-effective of the aneurysm intra-artery GDC embolization and the aneurysm incarcerated operation

    International Nuclear Information System (INIS)

    Pan Jie; Zhang Shizheng

    2008-01-01

    Objective: To evaluate the cost-effectiveness of the aneurysm intra-artery GDC embolization and the aneurysm clapping of intracranial aneurysm, and to give the instruction for the clinical practice. Methods: A case control study (1 vs. 1) was developed to evaluate the cost in hospital, the cost for return visit and the Quality-adusted Life-Year (QALY) and lifetime costs of the intra-artery GDC embolization and the aneurysm clapping of intraeranial aneurysm, under the matching of the age, sex, living place, the size and place of the aneurysm, and the Hunt and Hess score. Clinically effectiveness dates were derived from the medical records. Cost dates were derived from follow-up by telephones or letters. The correlation analysis was done with the SPSS 13.0. Results: The cost in hospital in AC group was (54 945±16 946)RMBs, which was higher than the ones in AE group (63 768±12 665) RMBs, (t=1.71, P 0.05). Conclusion: The results suggest that the two therapies have no difference in cost effective rate. Considering the physical and mental loss, the aneurysm intra-arteu GDC embolization was better than the aneurysm clapping for the patients with aneurysm that diameter less than 25 mm. (authors)

  19. Brain Aneurysm

    Science.gov (United States)

    A brain aneurysm is an abnormal bulge or "ballooning" in the wall of an artery in the brain. They are sometimes called berry aneurysms because they ... often the size of a small berry. Most brain aneurysms produce no symptoms until they become large, ...

  20. Investigation of the velocity field in a full-scale model of a cerebral aneurysm

    International Nuclear Information System (INIS)

    Roloff, Christoph; Bordás, Róbert; Nickl, Rosa; Mátrai, Zsolt; Szaszák, Norbert; Szilárd, Szabó; Thévenin, Dominique

    2013-01-01

    Highlights: • We investigate flow fields inside a phantom model of a full-scale cerebral aneurysm. • An artificial blood fluid is used matching viscosity and density of real blood. • We present Particle Tracking results of fluorescent tracer particles. • Instantaneous model inlet velocity profiles and volume flow rates are derived. • Trajectory fields at three of six measurement planes are presented. -- Abstract: Due to improved and now widely used imaging methods in clinical surgery practise, detection of unruptured cerebral aneurysms becomes more and more frequent. For the selection and development of a low-risk and highly effective treatment option, the understanding of the involved hemodynamic mechanisms is of great importance. Computational Fluid Dynamics (CFD), in vivo angiographic imaging and in situ experimental investigations of flow behaviour are powerful tools which could deliver the needed information. Hence, the aim of this contribution is to experimentally characterise the flow in a full-scale phantom model of a realistic cerebral aneurysm. The acquired experimental data will then be used for a quantitative validation of companion numerical simulations. The experimental methodology relies on the large-field velocimetry technique PTV (Particle Tracking Velocimetry), processing high speed images of fluorescent tracer particles added to the flow of a blood-mimicking fluid. First, time-resolved planar PTV images were recorded at 4500 fps and processed by a complex, in-house algorithm. The resulting trajectories are used to identify Lagrangian flow structures, vortices and recirculation zones in two-dimensional measurement slices within the aneurysm sac. The instantaneous inlet velocity distribution, needed as boundary condition for the numerical simulations, has been measured with the same technique but using a higher frame rate of 20,000 fps in order to avoid ambiguous particle assignment. From this velocity distribution, the time

  1. A methodology for developing anisotropic AAA phantoms via additive manufacturing.

    Science.gov (United States)

    Ruiz de Galarreta, Sergio; Antón, Raúl; Cazón, Aitor; Finol, Ender A

    2017-05-24

    An Abdominal Aortic Aneurysm (AAA) is a permanent focal dilatation of the abdominal aorta at least 1.5 times its normal diameter. The criterion of maximum diameter is still used in clinical practice, although numerical studies have demonstrated the importance of biomechanical factors for rupture risk assessment. AAA phantoms could be used for experimental validation of the numerical studies and for pre-intervention testing of endovascular grafts. We have applied multi-material 3D printing technology to manufacture idealized AAA phantoms with anisotropic mechanical behavior. Different composites were fabricated and the phantom specimens were characterized by biaxial tensile tests while using a constitutive model to fit the experimental data. One composite was chosen to manufacture the phantom based on having the same mechanical properties as those reported in the literature for human AAA tissue; the strain energy and anisotropic index were compared to make this choice. The materials for the matrix and fibers of the selected composite are, respectively, the digital materials FLX9940 and FLX9960 developed by Stratasys. The fiber proportion for the composite is equal to 0.15. The differences between the composite behavior and the AAA tissue are small, with a small difference in the strain energy (0.4%) and a maximum difference of 12.4% in the peak Green strain ratio. This work represents a step forward in the application of 3D printing technology for the manufacturing of AAA phantoms with anisotropic mechanical behavior. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Aneurysm Recurrence Volumetry Is More Sensitive than Visual Evaluation of Aneurysm Recurrences.

    Science.gov (United States)

    Schönfeld, M H; Schlotfeldt, V; Forkert, N D; Goebell, E; Groth, M; Vettorazzi, E; Cho, Y D; Han, M H; Kang, H-S; Fiehler, J

    2016-03-01

    Considerable inter-observer variability in the visual assessment of aneurysm recurrences limits its use as an outcome parameter evaluating new coil generations. The purpose of this study was to compare visual assessment of aneurysm recurrences and aneurysm recurrence volumetry with an example dataset of HydroSoft coils (HSC) versus bare platinum coils (BPC). For this retrospective study, 3-dimensional time-of-flight magnetic resonance angiography datasets acquired 6 and 12 months after endovascular therapy using BPC only or mainly HSC were analyzed. Aneurysm recurrence volumes were visually rated by two observersas well as quantified by subtraction of the datasets after intensity-based rigid registration. A total of 297 aneurysms were analyzed (BPC: 169, HSC: 128). Recurrences were detected by aneurysm recurrence volumetry in 9 of 128 (7.0 %) treated with HSC and in 24 of 169 (14.2 %) treated with BPC (odds ratio: 2.39, 95 % confidence interval: 1.05-5.48; P = 0.039). Aneurysm recurrence volumetry revealed an excellent correlation between observers (Cronbach's alpha = 0.93). In contrast, no significant difference in aneurysm recurrence was found for visual assessment (3.9 % in HSC cases and 4.7 % in BPC cases). Recurrences were observed in aneurysms smaller than the sample median in 10 of 33 (30.3 %) by aneurysm recurrence volumetry and in 1 of 13 (7.7 %) by visual assessment. Aneurysm recurrences were detected more frequently by aneurysm recurrence volumetry when compared with visual assessment. By using aneurysm recurrence volumetry, differences between treatment groups were detected with higher sensitivity and inter-observer validity probably because of the higher detection rate of recurrences in small aneurysms.

  3. Aneurysmal wall enhancement and perianeurysmal edema after endovascular treatment of unruptured cerebral aneurysms

    International Nuclear Information System (INIS)

    Su, I. Chang; Willinsky, Robert A.; Agid, Ronit; Fanning, Noel F.

    2014-01-01

    Perianeurysmal edema and aneurysm wall enhancement are previously described phenomenon after coil embolization attributed to inflammatory reaction. We aimed to demonstrate the prevalence and natural course of these phenomena in unruptured aneurysms after endovascular treatment and to identify factors that contributed to their development. We performed a retrospective analysis of consecutively treated unruptured aneurysms between January 2000 and December 2011. The presence and evolution of wall enhancement and perianeurysmal edema on MRI after endovascular treatment were analyzed. Variable factors were compared among aneurysms with and without edema. One hundred thirty-two unruptured aneurysms in 124 patients underwent endovascular treatment. Eighty-five (64.4 %) aneurysms had wall enhancement, and 9 (6.8 %) aneurysms had perianeurysmal brain edema. Wall enhancement tends to persist for years with two patterns identified. Larger aneurysms and brain-embedded aneurysms were significantly associated with wall enhancement. In all edema cases, the aneurysms were embedded within the brain and had wall enhancement. Progressive thickening of wall enhancement was significantly associated with edema. Edema can be symptomatic when in eloquent brain and stabilizes or resolves over the years. Our study demonstrates the prevalence and some appreciation of the natural history of aneurysmal wall enhancement and perianeurysmal brain edema following endovascular treatment of unruptured aneurysms. Aneurysmal wall enhancement is a common phenomenon while perianeurysmal edema is rare. These phenomena are likely related to the presence of inflammatory reaction near the aneurysmal wall. Both phenomena are usually asymptomatic and self-limited, and prophylactic treatment is not recommended. (orig.)

  4. Coronary artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Koischwitz, D.; Harder, T.; Schuppan, U.; Thurn, P.

    1982-04-01

    Seven saccular coronary artery aneurysms have been demonstrated in the course of 1452 selective coronary artery angiograms. In six patients they were arterio-sclerotic; in one patient the aneurysm must have been congenital or of mycotic-embolic origin. The differential diagnosis between true aneurysms and other causes of vascular dilatation is discussed. Coronary artery aneurysms have a poor prognosis because of the possibility of rupture with resultant cardiac tamponade, or the development of thrombo-embolic myocardial infarction. These aneurysms can only be diagnosed by means of coronary angiography and require appropriate treatment.

  5. Comparison of the strain field of abdominal aortic aneurysm measured by magnetic resonance imaging and stereovision: a feasibility study for prediction of the risk of rupture of aortic abdominal aneurysm.

    Science.gov (United States)

    Wang, Yufei; Joannic, David; Delassus, Patrick; Lalande, Alain; Juillion, Patrick; Fontaine, Jean-François

    2015-04-13

    The prediction of the risk of rupture of abdominal aortic aneurysm (AAA) is a complex problem. Currently the criteria to predict rupture of abdominal aortic aneurysms are aneurysm diameter and growth rates. It is generally believed that study of the wall strain distribution could be helpful to find a better decision criterion for surgery of aortic aneurysms before their rupture. The wall strain distribution depends on many biological and biomechanical factors such as elastic properties of the aorta, turbulent blood flow, anatomy of the aorta, presence of thrombus or not and so on. Recently, numerical simulations to estimate rupture-potential have received many attentions. However, none of the medical imaging tools for screening and monitoring of AAAs were studied in terms of mechanical behavior and experimentally to demonstrate their capability to measure relevant variables. The aim of this study was to develop a metrological approach for deployment testing of the ability of techniques for measuring local in-vitro deformations based on comparison of stereovision and MRI. In this paper, we present the implementation approach and results of the study based on cylindrical phantoms with or without AAA representing, respectively, healthy and unhealthy artery. Through this study, an experimental device was developed for the behavior study of AAA during a cardiac cycle. The results show that the stereovision techniques used in laboratory is well suited and is qualitatively and quantitatively equivalent with MRI measurements. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Microsurgical treatment of carotid-ophthalmic aneurysm associated with multiple anterior and posterior circulation aneurysms

    Science.gov (United States)

    Wang, Jiantao; Kan, Zhisheng; Wang, Shuo

    2017-01-01

    Abstract Background: The clipping of multiple intracranial aneurysms in 1 stage is uncommon. In this case, we report clipping of an ophthalmic aneurysm associated with multiple anterior and posterior circulation aneurysms via the Dolenc approach. Methods: The main symptoms of the patient are headache, along with nausea and vomiting. The patient's arteriogram revealed a wide-necked aneurysm of the right ophthalmic artery, an irregular aneurysm of the anterior communicating artery, and a basilar artery aneurysm. The surgical intervention for these aneurysms is a challenge because of the complex anatomical relationship with the surrounding structures. The 3 aneurysms, which were not amenable to a single intervention, were successfully clipped in 1 incision. Results: After surgery, the patient reported feeling well. One year after surgery, the patient had no SAH recurrence. Conclusions: Occasionally, surgical treatment was used even for aneurysms of the carotid-ophthalmic artery with aneurysms of anterior communicating artery and basilar artery, which are contraindicated for interventional therapy. PMID:28422878

  7. Measurement with microscopic MRI and simulation of flow in different aneurysm models

    Energy Technology Data Exchange (ETDEWEB)

    Edelhoff, Daniel, E-mail: daniel.edelhoff@tu-dortmund.de; Frank, Frauke; Heil, Marvin; Suter, Dieter [Experimental Physics III, TU Dortmund University, Otto-Hahn-Street 4, Dortmund 44227 (Germany); Walczak, Lars; Weichert, Frank [Computer Science VII, TU Dortmund University, Otto-Hahn-Street 16, Dortmund 44227 (Germany); Schmitz, Inge [Institute for Pathology, Ruhr Universität Bochum, Bürkle-de-la-Camp-Platz 1, Bochum 44789 (Germany)

    2015-10-15

    Purpose: The impact and the development of aneurysms depend to a significant degree on the exchange of liquid between the regular vessel and the pathological extension. A better understanding of this process will lead to improved prediction capabilities. The aim of the current study was to investigate fluid-exchange in aneurysm models of different complexities by combining microscopic magnetic resonance measurements with numerical simulations. In order to evaluate the accuracy and applicability of these methods, the fluid-exchange process between the unaltered vessel lumen and the aneurysm phantoms was analyzed quantitatively using high spatial resolution. Methods: Magnetic resonance flow imaging was used to visualize fluid-exchange in two different models produced with a 3D printer. One model of an aneurysm was based on histological findings. The flow distribution in the different models was measured on a microscopic scale using time of flight magnetic resonance imaging. The whole experiment was simulated using fast graphics processing unit-based numerical simulations. The obtained simulation results were compared qualitatively and quantitatively with the magnetic resonance imaging measurements, taking into account flow and spin–lattice relaxation. Results: The results of both presented methods compared well for the used aneurysm models and the chosen flow distributions. The results from the fluid-exchange analysis showed comparable characteristics concerning measurement and simulation. Similar symmetry behavior was observed. Based on these results, the amount of fluid-exchange was calculated. Depending on the geometry of the models, 7% to 45% of the liquid was exchanged per second. Conclusions: The result of the numerical simulations coincides well with the experimentally determined velocity field. The rate of fluid-exchange between vessel and aneurysm was well-predicted. Hence, the results obtained by simulation could be validated by the experiment. The

  8. Flow and wall shear stress characterization following endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model

    NARCIS (Netherlands)

    Boersen, Johannes T.; Groot Jebbink, Erik; Versluis, Michel; Slump, Cornelis H.; Ku, David N.; de Vries, Jean-Paul P.M.; Reijnen, Michel M.P.J.

    2017-01-01

    Background Endovascular aneurysm repair (EVAR) with a modular endograft has become the preferred treatment for abdominal aortic aneurysms. A novel concept is endovascular aneurysm sealing (EVAS), consisting of dual endoframes surrounded by polymer-filled endobags. This dual-lumen configuration is

  9. Infected aortic aneurysm and inflammatory aortic aneurysm. In search of an optimal differential diagnosis

    International Nuclear Information System (INIS)

    Ishizaka, Nobukazu; Sohmiya, Koichi; Miyamura, Masatoshi; Umeda, Tatsuya; Tsuji, Motomu; Katsumata, Takahiro; Miyata, Tetsuro

    2012-01-01

    Infected aortic aneurysm and inflammatory aortic aneurysm each account for a minor fraction of the total incidence of aortic aneurysm and are associated with periaortic inflammation. Despite the similarity, infected aortic aneurysm generally shows a more rapid change in clinical condition, leading to a fatal outcome; in addition, delayed diagnosis and misuse of corticosteroid or immunosuppressing drugs may lead to uncontrolled growth of microorganisms. Therefore, it is mandatory that detection of aortic aneurysm is followed by accurate differential diagnosis. In general, infected aortic aneurysm appears usually as a saccular form aneurysm with nodularity, irregular configuration; however, the differential diagnosis may not be easy sometimes for the following reasons: symptoms, such as abdominal and/or back pain and fever, and blood test abnormalities, such as elevated C-reactive protein and enhanced erythrocyte sedimentation rate, are common in infected aortic aneurysm, but they are not found infrequently in inflammatory aortic aneurysm; some inflammatory aortic aneurysms are immunoglobulin (Ig) G4-related, but not all of them; the prevalence of IgG4 positivity in infected aortic aneurysm has not been well investigated; enhanced uptake of 18F-fluorodeoxyglucose (FDG) by 18F-FDG-positron emission tomography may not distinguish between inflammation mediated by autoimmunity and that mediated by microorganism infection. Here we discuss the characteristics of these two forms of aortic aneurysm and the points of which we have to be aware before reaching a final diagnosis. (author)

  10. Microsurgical clipping of ophthalmic artery aneurysms: surgical results and visual outcomes with 208 aneurysms.

    Science.gov (United States)

    Kamide, Tomoya; Tabani, Halima; Safaee, Michael M; Burkhardt, Jan-Karl; Lawton, Michael T

    2018-01-26

    OBJECTIVE While most paraclinoid aneurysms can be clipped with excellent results, new postoperative visual deficits are a concern. New technology, including flow diverters, has increased the popularity of endovascular therapy. However, endovascular treatment of paraclinoid aneurysms is not without procedural risks, is associated with higher rates of incomplete aneurysm occlusion and recurrence, and may not address optic nerve compression symptoms that surgical debulking can. The increasing endovascular management of paraclinoid aneurysms should be justified by comparisons to surgical benchmarks. The authors, therefore, undertook this study to define patient, visual, and aneurysm outcomes in the most common type of paraclinoid aneurysm: ophthalmic artery (OphA) aneurysms. METHODS Results from microsurgical clipping of 208 OphA aneurysms in 198 patients were retrospectively reviewed. Patient demographics, aneurysm morphology (size, calcification, etc.), clinical characteristics, and patient outcomes were recorded and analyzed. RESULTS Despite 20% of these aneurysms being large or giant in size, complete aneurysm occlusion was accomplished in 91% of 208 cases, with OphA patency preserved in 99.5%. The aneurysm recurrence rate was 3.1% and the retreatment rate was 0%. Good outcomes (modified Rankin Scale score 0-2) were observed in 96.2% of patients overall and in all 156 patients with unruptured aneurysms. New visual field defects (hemianopsia or quadrantanopsia) were observed in 8 patients (3.8%), decreased visual acuity in 5 (2.4%), and monocular blindness in 9 (4.3%). Vision improved in 9 (52.9%) of the 17 patients with preoperative visual deficits. CONCLUSIONS The most important risk associated with clipping OphA aneurysms is a new visual deficit. Meticulous microsurgical technique is necessary during anterior clinoidectomy, aneurysm dissection, and clip application to optimize visual outcomes, and aggressive medical management postoperatively might potentially

  11. Aneurysm in the brain

    Science.gov (United States)

    ... gov/ency/article/001414.htm Aneurysm in the brain To use the sharing features on this page, ... aneurysm occurs in a blood vessel of the brain, it is called a cerebral, or intracranial, aneurysm. ...

  12. Hepatic artery aneurysms (HAAs)

    International Nuclear Information System (INIS)

    Nosratini, H.

    2004-01-01

    The hepatic artery aneurysms are rare, especially in interahepatic branches, The frequency consists of 75-80% extrahepatic and 20-25% intrahepatic. Catheterization is achieved usually from common femoral artery, other methods implemented in the case of unsuccessful catheterization from femoral artery, are translumbar and brachial catheterization. The study consist of 565 patients that were referred to the angiography ward, During seven years of assessment, five cases of hepatic artery aneurysm were found; this is a rare condition reported in the English literature. In the literature as well as in this case report the hepatic artery aneurysms are rare. In reported series the extrahepatic artery aneurysms are found more often than in the intrahepatic artery aneurysm but in this case report intrahepatic artery aneurysms are more than extrahepatic one. (author)

  13. Brain aneurysm repair - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000123.htm Brain aneurysm repair - discharge To use the sharing features ... this page, please enable JavaScript. You had a brain aneurysm . An aneurysm is a weak area in ...

  14. Influence of endoleaks on aneurysm volume and hemodynamics after endovascular aneurysm repair

    International Nuclear Information System (INIS)

    Pitton, M.B.; Welter, B.; Schmenger, P.; Thelen, M.; Dueber, C.; Neufang, A.

    2003-01-01

    Purpose: To evaluate the aneurysm volume and the intra-aneurysmatic pressure and maximal pressure pulse (dp/dtmax) in completely excluded aneurysms and cases with endoleaks. Materials and Methods: In 36 mongrel dogs, experimental autologous aneurysms were treated with stent-grafts. All aortic side branches were ligated in 18 cases (group I) but were preserved in group II (n=18). Aneurysm volumes were calculated from CT scans before and after intervention, and from follow-up CT scans at 1 week, 6 weeks and 6 months. Finally, for hemodynamic measurements, manometer-tipped catheters were introduced into the excluded aneurysm sac (group I and II), selectively in endoleaks (group II), and intraluminally for aortic reference measurement. Systemic hypertension was induced by volume load and pharmacologic stress. Pressure curves and dp/dt were simultaneously recorded and the ratios of aneurysm pressure to systemic reference pressure calculated. Results: At follow-up, type-II, endoleaks were excluded in all cases of group I by selective angiography. In contrast, endoleaks were evident in all cases of group II. Volumetric analysis of the aneurysms showed a benefit for group I with an improved aneurysm shrinkage: ΔVolume +0.08%, -1.62% and -9.76% at 1 week, 6 weeks and 6 months follow-up (median, group I), compared to +1.43%, +0.67%, and -4.04% (group II), p [de

  15. Endovascular treatment of very small intracranial aneurysms

    DEFF Research Database (Denmark)

    Iskandar, A; Nepper-Rasmussen, J

    2011-01-01

    to large aneurysms (> 3 mm). However the data also suggest that endovascular treatment of very small aneurysms might be associated with an increased risk of procedural ruptures and mortality. At nine-month follow-up results indicate significantly less compaction in the very small aneurysms....... endovascular treatment was attempted in 956 consecutive intracranial aneurysms. Of 956 aneurysms, 111 aneurysms were very small aneurysms with a maximal diameter of 3 mm or less. We conducted a retrospective analysis of angiographic and clinical outcome following coiling of very small aneurysms...... aneurysms and less than 90% aneurysm occlusion in six aneurysms. Complications occurred in the treatment of 15 aneurysms, including eight procedural ruptures, six thromboembolic events and one case of early hemorrhage. Compared with larger aneurysms, treatment of very small aneurysms was associated...

  16. Aneurysmal Subarachnoid Hemorrhage

    Science.gov (United States)

    2015-01-01

    Aneurysmal subarachnoid hemorrhage (SAH) is a worldwide health burden with high fatality and permanent disability rates. The overall prognosis depends on the volume of the initial bleed, rebleeding, and degree of delayed cerebral ischemia (DCI). Cardiac manifestations and neurogenic pulmonary edema indicate the severity of SAH. The International Subarachnoid Aneurysm Trial (ISAT) reported a favorable neurological outcome with the endovascular coiling procedure compared with surgical clipping at the end of 1 year. The ISAT trial recruits were primarily neurologically good grade patients with smaller anterior circulation aneurysms, and therefore the results cannot be reliably extrapolated to larger aneurysms, posterior circulation aneurysms, patients presenting with complex aneurysm morphology, and poor neurological grades. The role of hypothermia is not proven to be neuroprotective according to a large randomized controlled trial, Intraoperative Hypothermia for Aneurysms Surgery Trial (IHAST II), which recruited patients with good neurological grades. Patients in this trial were subjected to slow cooling and inadequate cooling time and were rewarmed rapidly. This methodology would have reduced the beneficial effects of hypothermia. Adenosine is found to be beneficial for transient induced hypotension in 2 retrospective analyses, without increasing the risk for cardiac and neurological morbidity. The neurological benefit of pharmacological neuroprotection and neuromonitoring is not proven in patients undergoing clipping of aneurysms. DCI is an important cause of morbidity and mortality following SAH, and the pathophysiology is likely multifactorial and not yet understood. At present, oral nimodipine has an established role in the management of DCI, along with maintenance of euvolemia and induced hypertension. Following SAH, hypernatremia, although less common than hyponatremia, is a predictor of poor neurological outcome. PMID:25272066

  17. The effect of endoleak on intra-aneurysmal pressure after EVE for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Huang Sheng; Jing Zaiping; Mei Zhijun; Lu Qingsheng; Zhao Jun; Zhang Suzhen; Zhao Xin; Cai Lili; Tang Jingdong; Xiong Jiang; Liao Mingfang

    2003-01-01

    Objective: To investigate the intra-aneurysmal pressure curve in the presence of endoleak after endovascular exclusion (EVE) for abdominal aortic aneurysm (AAA). Methods: Infrarenal aortic aneurysms were created with bovine jugular vein segments or patches. Then they were underwent incomplete endovascular exclusion of the aneurysm and formation of endoleaks. The pressures of blood flow outside the graft into the sac were measured. Results: The intrasac pressure was higher than systemic pressure in the presence of endoleak. After sealing the endoleak, pressure decreased significantly, and the pressure cure showed approximately linear. Conclusion: The change of intra-aneurysmal pressure curve reflected the load on aneurysmal wall after EVE, and can also help to determine the endoleak existence

  18. Treatment planning for image-guided neuro-vascular interventions using patient-specific 3D printed phantoms

    Science.gov (United States)

    Russ, M.; O'Hara, R.; Setlur Nagesh, S. V.; Mokin, M.; Jimenez, C.; Siddiqui, A.; Bednarek, D.; Rudin, S.; Ionita, C.

    2015-03-01

    Minimally invasive endovascular image-guided interventions (EIGIs) are the preferred procedures for treatment of a wide range of vascular disorders. Despite benefits including reduced trauma and recovery time, EIGIs have their own challenges. Remote catheter actuation and challenging anatomical morphology may lead to erroneous endovascular device selections, delays or even complications such as vessel injury. EIGI planning using 3D phantoms would allow interventionists to become familiarized with the patient vessel anatomy by first performing the planned treatment on a phantom under standard operating protocols. In this study the optimal workflow to obtain such phantoms from 3D data for interventionist to practice on prior to an actual procedure was investigated. Patientspecific phantoms and phantoms presenting a wide range of challenging geometries were created. Computed Tomographic Angiography (CTA) data was uploaded into a Vitrea 3D station which allows segmentation and resulting stereo-lithographic files to be exported. The files were uploaded using processing software where preloaded vessel structures were included to create a closed-flow vasculature having structural support. The final file was printed, cleaned, connected to a flow loop and placed in an angiographic room for EIGI practice. Various Circle of Willis and cardiac arterial geometries were used. The phantoms were tested for ischemic stroke treatment, distal catheter navigation, aneurysm stenting and cardiac imaging under angiographic guidance. This method should allow for adjustments to treatment plans to be made before the patient is actually in the procedure room and enabling reduced risk of peri-operative complications or delays.

  19. Aneurysm occlusion in elderly patients with aneurysmal subarachnoid haemorrhage : a cost-utility analysis

    NARCIS (Netherlands)

    Koffijberg, H.; Buskens, E.; Rinkel, G. J. E.

    Background Aneurysm occlusion after subarachnoid haemorrhage (SAH) aims to improve outcome by reducing the rebleeding risk. With increasing age, overall prognosis decreases, and the complications of aneurysm occlusion increase. The balance of risks for aneurysm occlusion in elderly SAH patients in

  20. Brain Aneurysm: Treatment Options

    Science.gov (United States)

    ... inoperable aneurysms. Decisions regarding management of an unruptured brain aneurysm are based on the careful comparison of the short- and ... so Tired? How Do I Deal With Depression? Learning Principles to Aid Recovery The Memory Book ... Aneurysm Foundation Support Community Research & Grants BAF Research ...

  1. Difference in aneurysm characteristics between patients with familial and sporadic aneurysmal subarachnoid haemorrhage

    NARCIS (Netherlands)

    Mensing, Liselore A.; Rinkel, Gabriel J E; Vlak, Monique H M; Van Der Schaaf, Irene C.; Ruigrok, Ynte M.

    2016-01-01

    Object Patients with familial intracranial aneurysms (IA) have a higher risk of rupture than patients with sporadic IA. We compared geometric and morphological risk factors for aneurysmal rupture between patients with familial and sporadic aneurysmal subarachnoid hemorrhage (aSAH) to analyse if

  2. Ex vivo repair of renal artery aneurysm associated with surgical treatment of abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Kostić Dušan M.

    2004-01-01

    Full Text Available INTRODUCTION Renal artery aneurysms is relatively uncommon with reported incidence ranges from 0.3% to 1%. However, considering all visceral artery aneurysms the percentage of renal artery aneurysms is relatively high between 15-25%. The distal forms of renal artery aneurysms sometimes require "ex vivo" reconstruction and kidney autotransplantation. CASE REPORT A 75-year-old male presented with the right abdominal and back pain. He suffered from a long history of arterial hypertension and chronic renal failure over the last few months (urea blood = 19.8 mmol/l; creatinine = 198 mmol/l. Duplex ultrasonography showed abdominal aortic aneurysm. Subsequent translumbarangiography revealed juxtarenal abdominal aortic aneurysm associated with distal right renal artery aneurysm. The operation was performed under combined thoracic epidural analgesia and general anesthesia using transperitoneal approach. After the laparotomy, the ascending colon was mobilized and reflected medially followed by Kocher maneuver. The result was visualization of the anterior aspect of the right kidney, the collecting system, ureter as well as the right renal vein and artery with large saccular aneurysm located distally. After mobilization of the renal vessels and careful dissection of the ureter, the kidney was explanted. The operation was continued by two surgical teams. The first team performed abdominal aortic aneurysm resection and reconstruction with bifurcated Dacron graft. The second team performed ex vivo reparation of renal artery aneurysm. All time during the explantation, the kidney was perfused by Collins' solution. The saccular right renal artery aneurysm 4 cm in diameter was located at the kidney hilus at the first bifurcation. Three branches originated from the aneurysm. The aneurysm was resected completely. The longest and widest of three branches arising from the aneurysmal sac was end-to-end anastomized with 6 mm PTFE graft. After this intervention, one of

  3. Brain Aneurysm Statistics and Facts

    Science.gov (United States)

    ... Statistics and Facts A- A A+ Brain Aneurysm Statistics and Facts An estimated 6 million people in ... Understanding the Brain Warning Signs/ Symptoms Brain Aneurysm Statistics and Facts Seeking Medical Attention Risk Factors Aneurysm ...

  4. Vascular Variations Associated with Intracranial Aneurysms.

    Science.gov (United States)

    Orakdogen, Metin; Emon, Selin Tural; Somay, Hakan; Engin, Taner; Is, Merih; Hakan, Tayfun

    2017-01-01

    To investigate the vascular variations in patients with intracranial aneurysm in circle of Willis. We used the data on 128 consecutive intracranial aneurysm cases. Cerebral angiography images were analyzed retrospectively. Arteries were grouped as anterior cerebral arterial system (ACS), posterior cerebral arterial system (PCS) and middle cerebral arterial system (MCS) for grouping vascular variations. Lateralization, being single/multiple, gender; and also any connection with accompanying aneurysms" number, localization, dimension, whether bleeding/incidental aneurysm has been inspected. Variations were demonstrated in 57.8% of the cases. The most common variation was A1 variation (34.4%). The rate of variations was 36.7%, 24.2% and 10.2% respectively in ACS, PCS and MCS. MCS variations were significantly higher in males. Anterior communicating artery (ACoA) aneurysm observance rates were significantly higher and posterior communicating artery (PCoA) aneurysm and middle cerebral artery (MCA) aneurysm observance rates were significantly lower when compared to "no ACS variation detected" cases. In "PCS variation detected" cases, PCoA aneurysm observance rates and coexistence of multiple variations were significantly higher. The rate of vascular variations in patients with aneurysms was 57.8%. Arterial hypoplasia and aplasia were the most common variations. ACS was the most common region that variations were located in; they were mostly detected on the right side. Coexistence of ACoA aneurysm was higher than PCoA and MCA aneurysms. In the PCS variations group, PCoA aneurysms were the most common aneurysms that accompanying the variation and multiple variations were more common than in the other two groups. The variations in MCS were most common in males.

  5. Symbol phantoms

    International Nuclear Information System (INIS)

    Yamaguchi, Hiroshi; Hongo, Syozo; Takeshita, Hiroshi

    1990-01-01

    We have developed Japanese phantoms in two procedures for computation of organ doses exposed to internal and/or external radiation sources. One method is to make mathematical phantoms on the basis of ORNL mathematical phantoms. Parameters to specify organs of Japanese mathematical phantom are determined by interpolations of the ORNL data, which define the organs of Caucasian males and females of various ages, i.e. new born, 1, 5, 10, 15 years and adult, with survey data for Japanese physiques. Another procedure is to build 'symbol phantoms' for the Japanese public. The concept and its method of the symbol phantom enables us to make a phantom for an individual when we have all of his transversal section images obtained by a medical imaging device like MRI, and thus we may achieve more realistic phantoms for Japanese public than the mathematical phantoms. Both studies are in progress in NIRS. (author)

  6. The influence of atmospheric pressure on aortic aneurysm rupture--is the diameter of the aneurysm important?

    Science.gov (United States)

    Urbanek, Tomasz; Juśko, Maciej; Niewiem, Alfred; Kuczmik, Wacław; Ziaja, Damian; Ziaja, Krzysztof

    2015-01-01

    The rate of aortic aneurysm rupture correlates with the aneurysm's diameter, and a higher rate of rupture is observed in patients with larger aneurysms. According to the literature, contradictory results concerning the relationship between atmospheric pressure and aneurysm size have been reported. In this paper, we assessed the influence of changes in atmospheric pressure on abdominal aneurysm ruptures in relationship to the aneurysm's size. The records of 223 patients with ruptured abdominal aneurysms were evaluated. All of the patients had been admitted to the department in the period 1997-2007 from the Silesia region. The atmospheric pressures on the day of the rupture and on the days both before the rupture and between the rupture events were compared. The size of the aneurysm was also considered in the analysis. There were no statistically significant differences in pressure between the days of rupture and the remainder of the days within an analysed period. The highest frequency of the admission of patients with a ruptured aortic aneurysm was observed during periods of winter and spring, when the highest mean values of atmospheric pressure were observed; however, this observation was not statistically confirmed. A statistically non-significant trend towards the higher rupture of large aneurysms (> 7 cm) was observed in the cases where the pressure increased between the day before the rupture and the day of the rupture. This trend was particularly pronounced in patients suffering from hypertension (p = 0.1). The results of this study do not support the hypothesis that there is a direct link between atmospheric pressure values and abdominal aortic aneurysm ruptures.

  7. Ruptured submitral aneurysm

    Directory of Open Access Journals (Sweden)

    V. Shukla

    2016-09-01

    Full Text Available Submitral aneurysm is a rare entity, with around few hundred cases reported till date. Presentation can be varied. We describe here a case of submitral aneurysm in a young male with rupture into the left atrium cavity.

  8. Evaluation of Aneurysm Neck Angle Change After Endovascular Aneurysm Repair Clinical Investigations

    Energy Technology Data Exchange (ETDEWEB)

    Le, Trong Binh; Moon, Mi Hyoung [Inha University Hospital, Endovascular Training Center (Korea, Republic of); Jeon, Yong Sun, E-mail: radjeon@inha.ac.kr [Inha University Hospital, Inha University School of Medicine, Department of Radiology (Korea, Republic of); Hong, Kee Chun [Inha University School of Medicine, Department of Vascular Surgery (Korea, Republic of); Cho, Soon Gu [Inha University Hospital, Inha University School of Medicine, Department of Radiology (Korea, Republic of); Park, Keun-Myoung [Inha University School of Medicine, Department of Vascular Surgery (Korea, Republic of)

    2016-05-15

    PurposeTo evaluate the aneurysm neck angle changes and post-endovascular aneurysm repair (EVAR) complications.MethodsWe retrospectively analyzed 72 cases of elective EVAR for abdominal aortic aneurysm among 109 consecutive cases from December 2005 to April 2014. Patients were divided into angulated and non-angulated groups. The angulated group was defined as neck angulation ≥60°. Neck angle was evaluated pre- and post-EVAR during short- (within 1 month), mid- (3–6 months), and long-term (>1 year) follow-up. Aneurysm sac diameter change, aneurysm neck morphology other than angulation, endoleaks, and other post-procedural complications were also documented.ResultsA total of 34 patients were enrolled in the angulated group. There were no statistical differences in age, sex, follow-up duration, and aneurysm neck profile between the two groups (p > 0.05). Both groups showed statistically significant and consistent decreases in angulation during the follow-up period (p < 0.01). The angulated group revealed 22.45 % more straightening than the non-angulated group. Recoil of the Endurant device occurred in the angulated group. No statistically significant intergroup differences were observed in any endoleaks, complications, or re-intervention rates (p > 0.05). Pre-EVAR angle was the only predictor for post-procedural angle change (p < 0.001).ConclusionEVAR is applicable for patients with highly angulated aneurysm neck and provides consistent neck straightening over long-term follow-up. Recoil was evident in the angulated group using the Endurant device.

  9. Impact of Aneurysm Projection on Intraoperative Complications During Surgical Clipping of Ruptured Posterior Communicating Artery Aneurysms.

    Science.gov (United States)

    Fukuda, Hitoshi; Hayashi, Kosuke; Yoshino, Kumiko; Koyama, Takashi; Lo, Benjamin; Kurosaki, Yoshitaka; Yamagata, Sen

    2016-03-01

    Surgical clipping of ruptured posterior communicating artery (PCoA) aneurysms is a well-established procedure to date. However, preoperative factors associated with procedure-related risk require further elucidation. To investigate the impact of the direction of aneurysm projection on the incidence of procedure-related complications during surgical clipping of ruptured PCoA aneurysms. A total of 65 patients with ruptured PCoA aneurysms who underwent surgical clipping were retrospectively analyzed from a single-center, prospective, observational cohort database in this study. The aneurysms were categorized into lateral and posterior projection groups, depending on direction of the dome. Characteristics and operative findings of each projection group were identified. We also evaluated any correlation of aneurysm projection with the incidence of procedure-related complications. Patients with ruptured PCoA aneurysms with posterior projection more likely presented with good-admission-grade subarachnoid hemorrhage (P = .01, χ test) and were less to also have intracerebral hematoma (P = .01). These aneurysms were found to be associated with higher incidence of intraoperative rupture (P = .02), complex clipping with fenestrated clips (P = .02), and dense adherence to PCoA or its perforators (P = .04) by univariate analysis. Aneurysms with posterior projection were also correlated with procedure-related complications, including postoperative cerebral infarction or hematoma formation (odds ratio, 5.87; 95% confidence interval, 1.11-31.1; P = .04) by multivariable analysis. Ruptured PCoA aneurysms with posterior projection carried a higher risk of procedure-related complications of surgical clipping than those with lateral projection.

  10. Aneurysmal subarachnoid hemorrhage: outcome of aneurysm clipping versus coiling in anterior circulation aneurysm

    International Nuclear Information System (INIS)

    Wadd, I.H.; Haroon, A.; Ansari, S.

    2015-01-01

    To compare the neurological outcome of microsurgical clipping versus coiling in patients with anterior circulation aneurysm. Study Design: Comparative study. Place and Duration of Study: Department of Neurosurgery, Lahore General Hospital, Lahore, from January 2010 to December 2013. Methodology: Patients aged 14 - 60 years, with ruptured cerebral aneurysm of anterior circulation and World Federation of Neurosurgical Society (WFNS) grades 1, 2 and 3 were included. Patients more than 60 years, medically unfit patient and posterior circulation aneurysms and WFNS grades 4 and 5 were excluded. Aneurysm sac obliteration was done in randomized manner with microsurgical clipping or coiling. Postoperatively, the patients were assessed and followed-up upto one year for outcome parameters on the bases of WFNS grade and Modified Ranking Scale (mRS) as favourable (mRS =2 ) and unfavourable (mRS > 2). Results: Among 140 subjects selected for study, 70 were included in group A, i.e. coiling and other 70 were in group B, i.e. clipping. The median age of patients in group A was 52.5 ± 10 years and in group B was 51.00 ± years. Overall, 56 (40%) males, 28 (60%) males in each group; and 84 (60%) females, 42 (60%) in each group were included. The male to female ratio in this study was 1:1.5. In group A, i.e. coiling, 27 (38.6%) patients had no disability (grades 1 and 2), 25 (35.7%) were slightly disabled (grade 3) and 18 (25.7%) had moderate disability (grade 4); whereas in group B, i.e. clipping group 23 (32.9%) patients had no disability (grades 1 and 2), 23 (32.9%) were slightly disabled (grade 3) and 24 (34.3%) had moderate disability (grade 4). At one year follow-up, in group A, favourable outcome was achieved in 56 (80%) of patients compared to 48 (68.6%) in group B; whilst, 14 (20%) patients in group A and 22 (33.1%) in group B showed unfavourable outcome. Although mortality rate was higher in clipping (n=3, 4.3%) as compared to coiling (n=1, 1.4%), but was not statistically

  11. Transcatheter Coil Embolization of Splenic Artery Aneurysm

    International Nuclear Information System (INIS)

    Yamamoto, Satoshi; Hirota, Shozo; Maeda, Hiroaki; Achiwa, Sachiko; Arai, Keisuke; Kobayashi, Kaoru; Nakao, Norio

    2008-01-01

    The purpose of this study was to evaluate clinical results and technical problems of transcatheter coil embolization for splenic artery aneurysm. Subjects were 16 patients (8 men, 8 women; age range, 40-80 years) who underwent transcatheter embolization for splenic artery aneurysm (14 true aneurysms, 2 false aneurysms) at one of our hospitals during the period January 1997 through July 2005. Two aneurysms (12.5%) were diagnosed at the time of rupture. Multiple splenic aneurysms were found in seven patients. Aneurysms were classified by site as proximal (or strictly ostial) (n = 3), middle (n = 3), or hilar (n = 10). The indication for transcatheter arterial embolization was a false or true aneurysm 20 mm in diameter. Embolic materials were fibered coils and interlocking detachable coils. Embolization was performed by the isolation technique, the packing technique, or both. Technically, all aneurysms were devascularized without severe complications. Embolized aneurysms were 6-40 mm in diameter (mean, 25 mm). Overall, the primary technical success rate was 88% (14 of 16 patients). In the remaining 2 patients (12.5%), partial recanalization occurred, and re-embolization was performed. The secondary technical success rate was 100%. Seven (44%) of the 16 study patients suffered partial splenic infarction. Intrasplenic branching originating from the aneurysm was observed in five patients. We conclude that transcatheter coil embolization should be the initial treatment of choice for splenic artery aneurysm

  12. Conversion of ICRP male reference phantom to polygon-surface phantom

    Science.gov (United States)

    Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi

    2013-10-01

    The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (original ICRP reference phantoms, it is believed that the polygon-surface version of ICRP reference phantoms properly developed will not only provide the same or similar dose values (say, difference <5 or 10%) for highly penetrating radiations, but also provide correct dose values for the weakly penetrating

  13. Primary extracranial vertebral artery aneurysms.

    Science.gov (United States)

    Morasch, Mark D; Phade, Sachin V; Naughton, Peter; Garcia-Toca, Manuel; Escobar, Guillermo; Berguer, Ramon

    2013-05-01

    Extracranial vertebral artery aneurysms are uncommon and are usually associated with trauma or dissection. Primary cervical vertebral aneurysms are even rarer and are not well described. The presentation and natural history are unknown and operative management can be difficult. Accessing aneurysms at the skull base can be difficult and, because the frail arteries are often afflicted with connective tissue abnormalities, direct repair can be particularly challenging. We describe the presentation and surgical management of patients with primary extracranial vertebral artery aneurysms. In this study we performed a retrospective, multi-institutional review of patients with primary aneurysms within the extracranial vertebral artery. Between January 2000 and January 2011, 7 patients, aged 12-56 years, were noted to have 9 primary extracranial vertebral artery aneurysms. All had underlying connective tissue or another hereditary disorder, including Ehler-Danlos syndrome (n=3), Marfan's disease (n=2), neurofibromatosis (n=1), and an unspecified connective tissue abnormality (n=1). Eight of 9 aneurysms were managed operatively, including an attempted bypass that ultimately required vertebral ligation; the contralateral aneurysm on this patient has not been treated. Open interventions included vertebral bypass with vein, external carotid autograft, and vertebral transposition to the internal carotid artery. Special techniques were used for handling the anastomoses in patients with Ehler-Danlos syndrome. Although endovascular exclusion was not performed in isolation, 2 hybrid procedures were performed. There were no instances of perioperative stroke or death. Primary extracranial vertebral artery aneurysms are rare and occur in patients with hereditary disorders. Operative intervention is warranted in symptomatic patients. Exclusion and reconstruction may be performed with open and hybrid techniques with low morbidity and mortality. Copyright © 2013 Elsevier Inc. All rights

  14. MR angiography of cerebral aneurysms

    International Nuclear Information System (INIS)

    Miki, Hitoshi; Tanada, Shuji; Sakaki, Saburo; Hamamoto, Ken; Sadamoto, Kazuhiko.

    1992-01-01

    Time-of-flight (TOF) MR angiography (MRA) and phase-contrast (PC) MRA are examined clinically for evaluating cerebral aneurysms. In the morphological diagnosis of cerebral aneurysms, three-dimensional (3D) MRA is superior to two-dimensional (2D) MRA because 3D MRA has a higher S/N ratio and a higher spatial resolution. However, it is difficult to decide which, 3D TOF MRA or 3D PC MRA, is superior, for both methods have many scan parameters. In our study, 3D PC MRA was performed using two methods; one had the same acquisition time as 3D TOF MRA, while the other had the same spatial resolution as 3D TOF MRA. The detectability of aneurysms by each MRA method was evaluated in comparison with 3D TOF MRA. In fifteen patients (6 males and 9 females), a total of 16 cerebral aneurysms (3 ruptured and 13 unruptured) were studied. The lesion sizes ranged from 2.5 to 18 mm. All the 16 lesions were examined by means of 3D TOF MRA, 3D PC MRA, and conventional angiography. MR imaging was performed with a 1.5 tesla MRI system (Signa). All of the 16 cerebral aneurysms were detected by 3D TOF MRA, while only 11 of them were detected by 3D PC MRA. When 3D PC MRA was performed with the same acquisition time as 3D TOF MRA, 3D PC MRA was superior in showing one of the 7 aneurysms. When 3D PC MRA was performed with same spatial resolution as 3D TOF MRA, 3D PC MRA was superior in showing two of the 10 aneurysms. 3D TOF MRA was superior to 3D PC MRA in the detection of cerebral aneurysms because of the long acquisition times and the different flow velocity, which induced different signal intensities between the aneurysms and parent arteries in 3D PC MRA. 3D PC MRA was superior to 3D TOF MRA in patients with large thrombotic aneurysms of the internal carotid artery. We consider that 3D TOF MRA should be the first choice for screening and following-up cerebral aneurysms. 3D PC MRA should then be performed for large cerebral aneurysms in addition to 3D TOF MRA. (author)

  15. Conversion of ICRP male reference phantom to polygon-surface phantom

    International Nuclear Information System (INIS)

    Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi

    2013-01-01

    The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (<2 man-months), we were able to construct the polygon-surface phantom with the organ masses perfectly matching the ICRP reference values. The analysis of the calculated dose values also implies that the dose values are indeed not very sensitive to the detailed morphology of the organ models in the phantom

  16. Morphological parameters associated with ruptured posterior communicating aneurysms.

    Science.gov (United States)

    Ho, Allen; Lin, Ning; Charoenvimolphan, Nareerat; Stanley, Mary; Frerichs, Kai U; Day, Arthur L; Du, Rose

    2014-01-01

    The rupture risk of unruptured intracranial aneurysms is known to be dependent on the size of the aneurysm. However, the association of morphological characteristics with ruptured aneurysms has not been established in a systematic and location specific manner for the most common aneurysm locations. We evaluated posterior communicating artery (PCoA) aneurysms for morphological parameters associated with aneurysm rupture in that location. CT angiograms were evaluated to generate 3-D models of the aneurysms and surrounding vasculature. Univariate and multivariate analyses were performed to evaluate morphological parameters including aneurysm volume, aspect ratio, size ratio, distance to ICA bifurcation, aneurysm angle, vessel angles, flow angles, and vessel-to-vessel angles. From 2005-2012, 148 PCoA aneurysms were treated in a single institution. Preoperative CTAs from 63 patients (40 ruptured, 23 unruptured) were available and analyzed. Multivariate logistic regression revealed that smaller volume (p = 0.011), larger aneurysm neck diameter (0.048), and shorter ICA bifurcation to aneurysm distance (p = 0.005) were the most strongly associated with aneurysm rupture after adjusting for all other clinical and morphological variables. Multivariate subgroup analysis for patients with visualized PCoA demonstrated that larger neck diameter (p = 0.018) and shorter ICA bifurcation to aneurysm distance (p = 0.011) were significantly associated with rupture. Intracerebral hemorrhage was associated with smaller volume, larger maximum height, and smaller aneurysm angle, in addition to lateral projection, male sex, and lack of hypertension. We found that shorter ICA bifurcation to aneurysm distance is significantly associated with PCoA aneurysm rupture. This is a new physically intuitive parameter that can be measured easily and therefore be readily applied in clinical practice to aid in the evaluation of patients with PCoA aneurysms.

  17. Symptomatic unruptured cerebral aneurysms. Features and surgical outcome

    International Nuclear Information System (INIS)

    Date, Isao

    2010-01-01

    Development of less invasive imaging studies, such as magnetic resonance angiography, has increased the chances that unruptured cerebral aneurysms are found. The rupture risk of 'symptomatic' aneurysms is higher than for 'asymptomatic' aneurysms; so 'symptomatic' aneurysms are more often surgically treated. Many reviews examine 'asymptomatic' unruptured cerebral aneurysms, but few evaluate 'symptomatic' aneurysms. The author has treated many patients with symptomatic unruptured cerebral aneurysms and found that improved cranial nerve signs can be expected if the surgical treatment is performed before the symptoms become irreversible; the critical period is approximately 3 months. It is important to suppress the pulsation of the aneurysms compressing the cranial nerves; both a clipping procedure and endovascular coiling are effective. Cranial nerve signs are more commonly the symptoms of unruptured cerebral aneurysms, but large to giant aneurysms can also be the causes of hemiparesis, hydrocephalus, epilepsy, or even cerebral infarction. This review summarizes the features and surgical outcome of symptomatic unruptured cerebral aneurysms. (author)

  18. A comparative study on patient specific absolute dosimetry using slab phantom, acrylic body phantom and goat head phantom

    Directory of Open Access Journals (Sweden)

    Om Prakash Gurjar

    2015-01-01

    Full Text Available Purpose: To compare the results of patient specific absolute dosimetry using slab phantom, acrylic body phantom and goat head phantom. Methods: Fifteen intensity modulated radiotherapy (IMRT plans already planned on treatment planning system (TPS for head-and-neck cancer patients were exported on all three kinds of phantoms viz. slab phantom, acrylic body phantom and goat head phantom, and dose was calculated using anisotropic analytic algorithm (AAA. All the gantry angles were set to zero in case of slab phantom while set to as it is in actual plan in case of other two phantoms. All the plans were delivered by linear accelerator (LA and dose for each plan was measured by 0.13 cc ion chamber. The percentage (% variations between planned and measured doses were calculated and analyzed. Results: The mean % variations between planned and measured doses of all IMRT quality assurance (QA plans were as 0.65 (Standard deviation (SD: 0.38 with confidence limit (CL 1.39, 1.16 (SD: 0.61 with CL 2.36 and 2.40 (SD: 0.86 with CL 4.09 for slab phantom, acrylic head phantom and goat head phantom respectively. Conclusion: Higher dose variations found in case of real tissue phantom compare to results in case of slab and acrylic body phantoms. The algorithm AAA does not calculate doses in heterogeneous medium as accurate as it calculates in homogeneous medium. Therefore the patient specific absolute dosimetry should be done using heterogeneous phantom mimicking density wise as well as design wise to the actual human body.  

  19. Combined treatment for complex intracranial aneurysm

    Directory of Open Access Journals (Sweden)

    Chiriac A.

    2015-06-01

    Full Text Available Complex aneurysms often cannot be completely excluded by a single approaches. Today successful treatment of these lesions requires a combination between microsurgical and endovascular techniques. Planning of combined treatment require a very good understanding of aneurysm anatomy and a close collaboration between neurosurgeon and neuroendovascular interventionist. Endovascular coiling can usually be used as early treatment for a partially aneurysm occlusion including the ruptured area and followed by definitive clipping. On the other hand microsurgical clipping also can be used as first treatment for complex aneurysm neck reconstruction, allowing successful secondary placement of coils inside the remnant aneurysm sac

  20. Giant true celiac artery aneurysm

    International Nuclear Information System (INIS)

    Aljabri, Badr

    2009-01-01

    Celiac artery aneurysms are rare and usually asymptomatic. The management of these aneurysms is challenging, especially when they are large and involve the confluence of the trifurcation. We present here a case of a large celiac artery aneurysm involving its branches in a young woman. Preoperative investigations, intraoperative findings, and the operative procedure are also presented and discussed. (author

  1. Early Enlargement of Aneurysmal Sac and Separation of EndoBags of Nellix Endovascular Aneurysm Sealing System as Signs of Increased Risk of Later Aneurysm Rupture

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Lik Fai, E-mail: rickieclf@yahoo.com.hk [Princess Margaret Hospital, Department of Radiology (China); Cheung, Kwok Fai; Chan, Kwong Man [Princess Margaret Hospital, Department of Surgery (China); Ma, Johnny Ka Fai; Luk, Wing Hang [Princess Margaret Hospital, Department of Radiology (China); Chan, Micah Chi King [Princess Margaret Hospital, Department of Surgery (China); Ng, Carol Wing Kei; Mahboobani, Neeraj Ramesh [Princess Margaret Hospital, Department of Radiology (China); Ng, Wai Kin [Princess Margaret Hospital, Department of Surgery (China); Wong, Ting [Princess Margaret Hospital, Department of Radiology (China)

    2016-11-15

    Nellix Endovascular Aneurysm Sealing (EVAS) system is a new concept and technology of abdominal aortic aneurysm (AAA) repair. Elective EVAS using Nellix device was performed for a 83-year-old man with AAA. 2-month post-EVAS CTA surveillance demonstrated mild enlargement of aneurysmal sac and separation of the EndoBags, but without detectable endoleak. The patient developed sudden AAA rupture with retroperitoneal hematoma at about 4 months after EVAS. We postulated that early enlargement of aneurysmal sac and separation of EndoBags of Nellix devices after EVAS, even without detectable endoleak, might indicate significant aneurysmal wall weakening with increased risk of later AAA rupture. To the best of the authors’ knowledge, this was the first reported case of aortic rupture after EVAS without detectable endoleak during and after the procedure.

  2. Early Enlargement of Aneurysmal Sac and Separation of EndoBags of Nellix Endovascular Aneurysm Sealing System as Signs of Increased Risk of Later Aneurysm Rupture

    International Nuclear Information System (INIS)

    Cheng, Lik Fai; Cheung, Kwok Fai; Chan, Kwong Man; Ma, Johnny Ka Fai; Luk, Wing Hang; Chan, Micah Chi King; Ng, Carol Wing Kei; Mahboobani, Neeraj Ramesh; Ng, Wai Kin; Wong, Ting

    2016-01-01

    Nellix Endovascular Aneurysm Sealing (EVAS) system is a new concept and technology of abdominal aortic aneurysm (AAA) repair. Elective EVAS using Nellix device was performed for a 83-year-old man with AAA. 2-month post-EVAS CTA surveillance demonstrated mild enlargement of aneurysmal sac and separation of the EndoBags, but without detectable endoleak. The patient developed sudden AAA rupture with retroperitoneal hematoma at about 4 months after EVAS. We postulated that early enlargement of aneurysmal sac and separation of EndoBags of Nellix devices after EVAS, even without detectable endoleak, might indicate significant aneurysmal wall weakening with increased risk of later AAA rupture. To the best of the authors’ knowledge, this was the first reported case of aortic rupture after EVAS without detectable endoleak during and after the procedure.

  3. Interobserver variability in the assessment of aneurysm occlusion with the WEB aneurysm embolization system.

    Science.gov (United States)

    Fiorella, David; Arthur, Adam; Byrne, James; Pierot, Laurent; Molyneux, Andy; Duckwiler, Gary; McCarthy, Thomas; Strother, Charles

    2015-08-01

    The WEB (WEB aneurysm embolization system, Sequent Medical, Aliso Viejo, California, USA) is a self-expanding, nitinol, mesh device designed to achieve aneurysm occlusion after endosaccular deployment. The WEB Occlusion Scale (WOS) is a standardized angiographic assessment scale for reporting aneurysm occlusion achieved with intrasaccular mesh implants. This study was performed to assess the interobserver variability of the WOS. Seven experienced neurovascular specialists were trained to apply the WOS. These physicians independently reviewed angiographic image sets from 30 patients treated with the WEB under blinded conditions. No additional clinical information was provided. Raters graded each image according to the WOS (complete occlusion, residual neck or residual aneurysm). Final statistics were calculated using the dichotomous outcomes of complete occlusion or incomplete occlusion. The interobserver agreement was measured by the generalized κ statistic. In this series of 30 test case aneurysms, observers rated 12-17 as completely occluded, 3-9 as nearly completely occluded, and 9-11 as demonstrating residual aneurysm filling. Agreement was perfect across all seven observers for the presence or absence of complete occlusion in 22 of 30 cases. Overall, interobserver agreement was substantial (κ statistic 0.779 with a 95% CI of 0.700 to 0.857). The WOS allows a consistent means of reporting angiographic occlusion for aneurysms treated with the WEB device. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  4. Tobacco smoking and aortic aneurysm

    DEFF Research Database (Denmark)

    Sode, Birgitte F; Nordestgaard, Børge; Grønbæk, Morten

    2013-01-01

    BACKGROUND: We determined the predictive power of tobacco smoking on aortic aneurysm as opposed to other risk factors in the general population. METHODS: We recorded tobacco smoking and other risk factors at baseline, and assessed hospitalization and death from aortic aneurysm in 15,072 individuals...... aneurysm in males and females consuming above 20g tobacco daily was 3.5% and 1.3%, among those >60years with plasma cholesterol >5mmol/L and a systolic blood pressure >140mmHg. CONCLUSIONS: Tobacco smoking is the most important predictor of future aortic aneurysm outcomes in the general population...

  5. Patient- and Aneurysm-Specific Risk Factors for Intracranial Aneurysm Growth : A Systematic Review and Meta-Analysis

    NARCIS (Netherlands)

    Backes, Daan; Rinkel, Gabriel J E; Laban, Kamil G.; Algra, Ale; Vergouwen, Mervyn D I

    2016-01-01

    BACKGROUND AND PURPOSE—: Follow-up imaging is often performed in intracranial aneurysms that are not treated. We performed a systematic review and meta-analysis on patient- and aneurysm-specific risk factors for aneurysm growth. METHODS—: We searched EMBASE and MEDLINE for cohort studies describing

  6. Retrospective analysis of the prevalence of asymptomatic cerebral aneurysm in 4518 patients undergoing magnetic resonance angiography. When does cerebral aneurysm develop?

    International Nuclear Information System (INIS)

    Horikoshi, Toru; Yamagata, Zentaro; Nukui, Hideaki; Akiyama, Iwao

    2002-01-01

    The natural history of cerebral aneurysms was investigated by measuring the prevalence of incidentally found unruptured aneurysms in the general population and evaluating the characteristics including risk factors. 'De novo' formation of aneurysm was also demographically estimated. The prevalence of incidental aneurysm was evaluated among 4518 patients who underwent magnetic resonance (MR) angiography for various reasons in a neurosurgical institute. Double the number of patients were randomly selected from the remaining patients without aneurysm as the Control group so that sex and age group were matched to the Aneurysm group. One hundred twenty seven patients (2.8%) had diagnoses of aneurysm. The prevalence of asymptomatic aneurysm among middle-aged and elderly patients were predominant in women and increased with age in both sexes. Patients with aneurysms had significantly more hypertension and family history of subarachnoid hemorrhage compared to the controls. The prevalence was markedly increased in the 8th decade in men and the 7th decade in women, and new aneurysms seemed to develop predominantly around these decades. Cerebral aneurysms become detectable on MR angiography in the middle or later decades, and women tend to develop aneurysm earlier than men. Hypertension and family history of subarachnoid hemorrhage are probably risk factors for the development of aneurysm. (author)

  7. The role of inflammation in cerebral aneurysms

    Directory of Open Access Journals (Sweden)

    Ali H Turkmani

    2015-06-01

    Full Text Available The natural history of unruptured intracranial aneurysms (IAs is poorly understood. At present, risk factors for aneurysm rupture are limited to demographics and rudimentary anatomic features of the aneurysm. The first sign of aneurysm destabilization and rupture may be subarachnoid hemorrhage, a potentially devastating brain injury with high morbidity and mortality. An emerging body of literature suggests a complex inflammatory cascade likely promotes aneurysm wall remodeling and progressive ballooning of the arterial wall, ultimately terminating in aneurysm rupture. These events likely begin with hemodynamic, flow-related endothelial injury; the injured endothelium stimulates inflammation, including the recruitment and transmigration of inflammatory cells, particularly macrophages. Various proteases are secreted by the inflammatory infiltrate, resulting in degradation of the extracellular matrix and the structural changes unique to IAs. Detailed understanding of these inflammatory processes may result in (1 early identification of patients at high risk for aneurysm rupture, perhaps via arterial wall imaging, and (2 targeted, noninvasive therapies to treat or even prevent cerebral aneurysms.

  8. Surgical management of recurrent intracranial aneurysms after embolization

    Directory of Open Access Journals (Sweden)

    Hua-wei WANG

    2015-03-01

    Full Text Available Background Endovascular therapy is the first treatment choice for intracranial aneurysms currently, but it has a high recurrence rate. Some patients require surgical clipping because of the difficulty of re-embolization. This study retrospectively analyzed the clinical data of 11 cases who underwent clipping operation because of the recurrence after endovascular therapy. Combining with domestic and foreign related literatures, this paper discusses the principles and techniques of surgical treatment for recurrent aneurysms.  Methods There were a total of 11 patients with 12 recurrent aneurysms after embolization, including 3 anterior communicating artery (ACoA aneurysms, 3 middle cerebral artery (MCA aneurysms, 2 posterior communicating artery (PCoA aneurysms, one anterior cerebral artery (ACA aneurysm, one vertebral artery (VA aneurysm, one basilar tip aneurysm and one superior cerebellar artery (SCA aneurysm. There were 7 small aneurysms and 4 large aneurysms. All patients underwent surgical clipping under microscope. After operation, 11 aneurysms were complete clipped, and one was proximally blocked. The coils were reserved in 7 aneurysms, and were removed or partially removed in 5 aneurysms.  Results All patients were followed up for an average of 22 months after surgery. There were 9 cases (9/11 with the Glasgow Outcome Scale (GOS score improved or remaining unchanged compared with preoperation. One of them presented left limb weakness after operation, with the muscle strength Grade 3, while recovered to Grade 4-5 on discharge. The other 2 patients died after surgery. One case had a critical condition before surgery, and the other was secondary to thrombosis and pneumonia. Both of them had a GOS score of 2 when discharged, and died after discharge.  Conclusions There is high surgical difficulty in recurrent aneurysms, however, with adequate preoperative evaluation and surgical design, it can still promise safe and effective results

  9. Ruptured gastroepiploic artery aneurysm: A case report

    Directory of Open Access Journals (Sweden)

    Ahmad S. Ashrafi

    Full Text Available Introduction: Gastroepiploic artery aneurysms are extremely rare, with few reported cases in the literature. The risk of rupture however, is high and thus warrants attention. Presentation of case: Here we present a rare case of a women who presented to the emergency department in shock and was found to have a ruptured gastroepiploic artery aneurysm during surgical exploration. Suture ligation of the aneurysm was completed. Discussion: Although rare, gastroepiploic artery aneurysms have up to a 90% rate of rupture and therefore require intervention. A laparoscopic approach has been described however, in cases where rupture has occurred, urgent laparotomy and control of hemorrhage is needed. Conclusion: We describe a rare case of a ruptured gastroepiploic aneurysm that was successfully managed with urgent laparotomy and aneurysmal resection. Keywords: Gastroepiploic, Aneurysm, Hemorrhage, Case report

  10. Intra-aneurysmal flow disruption after implantation of the Medina® Embolization Device depends on aneurysm neck coverage.

    Science.gov (United States)

    Frölich, Andreas Maximilian; Nawka, Marie Teresa; Ernst, Marielle; Frischmuth, Isabell; Fiehler, Jens; Buhk, Jan-Hendrik

    2018-01-01

    Flow disruption achieved by braided intrasaccular implants is a novel treatment strategy for cerebrovascular aneurysms. We hypothesized that the degree of intra-aneurysmal flow disruption can be quantified in vitro and is influenced by device position across the aneurysm neck. We tested this hypothesis using the Medina® Embolization Device (MED). Ten different patient-specific elastic vascular models were manufactured. Models were connected to a pulsatile flow circuit, filled with a blood-mimicking fluid and treated by two operators using a single MED. Intra-aneurysmal flow velocity was measured using conventional and high-frequency digital subtraction angiography (HF-DSA) before and after each deployment. Aneurysm neck coverage by the implanted devices was assessed with flat detector computed tomography on a three-point Likert scale. A total of 80 individual MED deployments were performed by the two operators. The mean intra-aneurysmal flow velocity reduction after MED implantation was 33.6% (27.5-39.7%). No significant differences in neck coverage (p = 0.99) or flow disruption (p = 0.84) were observed between operators. The degree of flow disruption significantly correlated with neck coverage (ρ = 0.42, 95% CI: 0.21-0.59, p = 0.002) as well as with neck area (ρ = -0,35, 95% CI: -0.54 --0.13, p = 0.024). On multiple regression analysis, both neck coverage and total neck area were independent predictors of flow disruption. The degree of intra-aneurysmal flow disruption after MED implantation can be quantified in vitro and varies considerably between different aneurysms and different device configurations. Optimal device coverage across the aneurysm neck improves flow disruption and may thus contribute to aneurysm occlusion.

  11. Abdominal Aortic Aneurysm (AAA)

    Science.gov (United States)

    ... Professions Site Index A-Z Abdominal Aortic Aneurysm (AAA) Abdominal aortic aneurysm (AAA) occurs when atherosclerosis or plaque buildup causes the ... weak and bulge outward like a balloon. An AAA develops slowly over time and has few noticeable ...

  12. Coil embolization of an enlarging fusiform myxomatous cerebral aneurysm

    Directory of Open Access Journals (Sweden)

    Frances Lazarow, MD

    2018-04-01

    Full Text Available Myxomatous cerebral aneurysms are rare sequelae of cardiac atrial myxoma. These aneurysms are generally fusiform, multiple, and distal. Pathogenesis and evolution of these aneurysms is still debated. There are currently no guidelines on the management of aneurysms secondary to atrial myxoma. We present a case of a 52-year-old man with multiple fusiform aneurysms 3 years after resection of a left atrial myxoma. One of these aneurysms was followed with cerebral angiography and showed substantial interval enlargement. This aneurysm was subsequently embolized. All aneurysms were stable 6 months post-embolization. Keywords: Myxomatous aneurysm, Fusiform, Coil embolization

  13. de novo'' aneurysms following endovascular procedures

    International Nuclear Information System (INIS)

    Briganti, F.; Cirillo, S.; Caranci, F.; Esposito, F.; Maiuri, F.

    2002-01-01

    Two personal cases of ''de novo'' aneurysms of the anterior communicating artery (ACoA) occurring 9 and 4 years, respectively, after endovascular carotid occlusion are described. A review of the 30 reported cases (including our own two) of ''de novo'' aneurysms after occlusion of the major cerebral vessels has shown some features, including a rather long time interval after the endovascular procedure of up to 20-25 years (average 9.6 years), a preferential ACoA (36.3%) and internal carotid artery-posterior communicating artery (ICA-PCoA) (33.3%) location of the ''de novo'' aneurysms, and a 10% rate of multiple aneurysms. These data are compared with those of the group of reported spontaneous ''de novo'' aneurysms after SAH or previous aneurysm clipping. We agree that the frequency of ''de novo'' aneurysms after major-vessel occlusion (two among ten procedures in our series, or 20%) is higher than commonly reported (0 to 11%). For this reason, we suggest that patients who have been submitted to endovascular major-vessel occlusion be followed up for up to 20-25 years after the procedure, using non-invasive imaging studies such as MR angiography and high-resolution CT angiography. On the other hand, periodic digital angiography has a questionable risk-benefit ratio; it may be used when a ''de novo'' aneurysm is detected or suspected on non-invasive studies. The progressive enlargement of the ACoA after carotid occlusion, as described in our case 1, must be considered a radiological finding of risk for ''de novo'' aneurysm formation. (orig.)

  14. Endovascular treatment for pediatric intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Xianli; Jiang, Chuhan; Li, Youxiang; Yang, Xinjian; Wu, Zhongxue [Capital Medical University, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Beijing, Hebei (China)

    2009-11-15

    The purpose of this study is to report the characteristics and outcomes of pediatric patients with intracranial aneurysms. From 1998 to 2005, 25 pediatric patients (aged {<=}17 years) with intracranial aneurysm were treated at our institute. Eleven of 25 patients had subarachnoid hemorrhage. In ten patients, the aneurysm was an incidental finding. One patient presented with cranial nerves dysfunction and three with neurological deficits. The locations of the aneurysms were as follows: vertebral artery (VA; n = 9), middle cerebral artery (MCA; n = 5), posterior cerebral artery (PCA; n = 4), basilar artery (BA; n = 2), anterior communicating artery (n = 2), anterior cerebral artery (n = 2), and internal carotid artery (n = 1). Five patients were treated with selective embolization with coils. Sixteen patients were treated with parent vessel occlusion (PVO). Eight PVOs were performed with balloons and eight were performed with coils. One patient with a VA aneurysm was spontaneously thrombosed 4 days after the initial diagnostic angiogram. In three patients treated with stent alone or stent-assisted coiling, one with BA trunk aneurysm died. One aneurismal recurrence occurred and was retreated. At a mean follow-up duration of 23.5 months, 96% of patients had a Glasgow Outcome Scale score of 4 or 5. Pediatric intracranial aneurysms occur more commonly in male patients and have a predilection for the VA, PCA, and MCA. PVO is an effective and safe treatment for fusiform aneurysms. Basilar trunk fusiform aneurysms were difficult to treat and were associated with a high mortality rate. (orig.)

  15. Appearance of femoropopliteal segment aneurysms in patients with abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Maksić Milanko

    2012-01-01

    Full Text Available Background/Aim. To promote better treatment outcome, as well as economic benefit it is very important to find out patients with simultaneous occurrence of both aortic and arterial aneurysms. The aim of this prospective study was to determine the frequency and factors affecting femoropopliteal (F-P segment aneurysms appearance in patients with abdominal aortic aneurysms (AAA. Methods. This study included 70 patients who had underwent elective or urgent surgery of AAA from January 1, 2006 to December 31, 2007. After ultrasonographic examination of F-P segment, all the patients were divided into two groups - those with adjunctive F-P segment aneurysm (n = 20 and the group of 50 patients with no adjunctive F-P segment aneurysm. In both groups demographic characteristics (gender, age, risk factors (diabetes mellitus, elevated serum levels of cholesterol and triglycerides, arterial hypertension, smoking, obesity and cardiovascular comorbidity (cerebrovascular desease, ischemic heart desease were investigated. Results. Twenty (28.57% patients who had been operated on because of AAA, had adjunctive aneurysmal desease of F-P segment. Diabetes was no statistically significantly more present among the patients who, beside AAA, had adjunctive aneurismal desease of F-P segment (χ2 = 0.04; DF = 1; p > 0.05. Also, in both groups there was no statistically significant difference in gender structure (χ2 = 2. 05; DF = 2; p > 0.05, age (χ2 = 5. 46; DF = 1; p > 0.05, total cholesterol level (χ2 = 0.89; DF = 1; p > 0.05 and triglyceride (χ2 = 0.89; DF = 1; p > 0.05 levels, the presence of arterial hypertension (χ2 = 1.38; DF = 2; p > 0.05, smoking (χ2 = 1.74; DF = 1; p > 0.05, obesity (χ2 = 1.76; DF = 1; p > 0.05 and presence of cerebrovascular desease (χ2 = 2.34; DF = 1; p > 0.05. Conversly, ischemic heart desease was statistically significantly more present among the patients who, beside AAA, had adjunctive aneurismal desease of F-P segment (χ2 = 5

  16. Development of a posterior cerebral artery aneurysm subsequent to occlusion of the contralateral internal carotid artery for giant cavernous aneurysm

    International Nuclear Information System (INIS)

    Wolf, R.L.; Hurst, R.W.; Imbesi, S.G.; Galetta, S.L.; Sinson, G.P.; Grossman, R.I.

    2002-01-01

    We report a case of a patient who developed a left posterior cerebral artery aneurysm 5 years after balloon occlusion of the right internal carotid artery for a giant cavernous aneurysm. The location of the new aneurysm was outside of the primary collateral pathways to the contralateral, proximally occluded, anterior circulation, illustrating the complexity of hemodynamic factors contributing to the development of intracranial saccular aneurysms. The appearance of an aneurysm in this setting supports the hypothesis that degenerative factors and hemodynamic stresses are important in the etiology of intracranial aneurysms. (orig.)

  17. Study on the related factors influencing the formation of intra-aneurysmal thrombosis in the established side-wall aneurysmal model in canine

    International Nuclear Information System (INIS)

    Zhou Bing; Li Minghua; Wang Jianbo; Zhu Yueqi; Yuan Jianhua; Yu Wenqiang

    2011-01-01

    Objective: To analyze the related factors influencing the formation of intra-aneurysmal thrombosis (IAT) in the established side-wall aneurysmal model in canine, and to discuss the measures to prevent the occurrence of IAT. Methods: Twenty canines were randomly divided into 4 groups for building side-wall aneurysmal model: group A, vertical aneurysm without use of postoperative anticoagulation medication; group B, vertical aneurysm with use of postoperative anticoagulation medication; group C, oblique aneurysm without use of postoperative anticoagulation medication; and group D, oblique aneurysm with use of postoperative anticoagulation medication. Angiography was performed to evaluate the IAT. The potential related factors influencing the formation of IAT, including sex, age, operative time, aneurysmal morphology, postoperative anticoagulation medication and cervical hematoma, were statistically analysed with emphasis on aneurysmal morphology and the use of postoperative anticoagulation medication. The statistical software SPSS 12.0 was employed. Results: A total of 40 aneurysms were successfully established in 20 canines. Cervical hematoma occurred in 7 canines and IAT developed in 8 aneurysms. The univariate analysis showed that the formation of IAT was significantly influenced by the aneurysmal morphology and cervical hematoma. Surprisingly, the formation of IAT bore no relation to the postoperative anticoagulation, whether the medication was employed or not, which was further confirmed by stratified analysis. Conclusion: To establish oblique aneurysm and to reduce the occurrence of cervical hematoma can effectively decrease the incidence of IAT in established side-wall aneurysmal model in canine. The postoperative anticoagulation medication can not decrease the incidence of IAT. (authors)

  18. Endovascular Exclusion of Renal Artery Aneurysm

    International Nuclear Information System (INIS)

    Andersen, Poul Erik; Rohr, Nils

    2005-01-01

    A patient who was operated for an abdominal aortic aneurysm 7 years earlier presented with recently discovered iliac and renal artery aneurysms. The renal artery had an angulation of 90 o , but the aneurysm was successfully excluded using a covered vascular stent graft placed over an extrastiff guidewire. Even in cases of complex anatomy of a renal aneurysm, endovascular treatment should be considered. With development of more flexible and low-profile endoprosthesis with accurate deployment, these have become more usable

  19. Giant serpentine intracranial aneurysm: a case report

    International Nuclear Information System (INIS)

    Park, Jae Seong; Lee, Myeong Sub; Kim, Myung Soon; Kim, Dong Jin; Park, Joong Wha; Whang, Kum

    2001-01-01

    The authors present a case of giant serpentine aneurysm (a partially thrombosed aneurysm containing tortuous vascular channels with a separate entrance and outflow pathway). Giant serpentine aneurysms form a subgroup of giant intracranial aneurysms, distinct from saccular and fusiform varieties, and in this case, too, the clinical presentation and radiographic features of CT, MR imaging and angiography were distinct

  20. Endovascular treatment of PICA aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Mukonoweshuro, W.; Laitt, R.D.; Hughes, D.G. [Radiology Dept., Greater Manchester Neurosciences Unit, Hope Hospital, Salford, Manchester (United Kingdom)

    2003-03-01

    Endovascular treatment of aneurysms of the posterior inferior cerebellar artery (PICA) avoids manipulation of the brainstem or lower cranial nerves and should therefore carry a lower risk of neurological morbidity than surgical clipping. We reviewed our experience of 23 patients with PICA aneurysms treated by endovascular occlusion with Guglielmi detachable coils and documented their long-term outcome on follow-up. We observed a 28 day procedure-related neurological morbidity of 13% (3/23 patients). One patient suffered permanent neurological complications. There were no procedure-related deaths. None of our patients suffered a re-bleed from their treated aneurysms. Our series shows endovascular treatment of ruptured PICA aneurysms to be safe and effective. (orig.)

  1. Epidemiology and genetics of intracranial aneurysms

    International Nuclear Information System (INIS)

    Caranci, F.; Briganti, F.; Cirillo, L.; Leonardi, M.; Muto, M.

    2013-01-01

    Intracranial aneurysms are acquired lesions (5–10% of the population), a fraction of which rupture leading to subarachnoid hemorrhage with devastating consequences. Until now, the exact etiology of intracranial aneurysms formation remains unclear. The low incidence of subarachnoid hemorrhage in comparison with the prevalence of unruptured IAs suggests that the vast majority of intracranial aneurysms do not rupture and that identifying those at highest risk is important in defining the optimal management. The most important factors predicting rupture are aneurysm size and site. In addition to ambiental factors (smoking, excessive alcohol consumption and hypertension), epidemiological studies have demonstrated a familiar influence contributing to the pathogenesis of intracranial aneurysms, with increased frequency in first- and second-degree relatives of people with subarachnoid hemorrhage. In comparison to sporadic aneurysms, familial aneurysms tend to be larger, more often located at the middle cerebral artery, and more likely to be multiple. Other than familiar occurrence, there are several heritable conditions associated with intracranial aneurysm formation, including autosomal dominant polycystic kidney disease, neurofibromatosis type I, Marfan syndrome, multiple endocrine neoplasia type I, pseudoxanthoma elasticum, hereditary hemorrhagic telangiectasia, and Ehlers-Danlos syndrome type II and IV. The familial occurrence and the association with heritable conditions indicate that genetic factors may play a role in the development of intracranial aneurysms. Genome-wide linkage studies in families and sib pairs with intracranial aneurysms have identified several loci on chromosomes showing suggestive evidence of linkage, particularly on chromosomes 1p34.3–p36.13, 7q11, 19q13.3, and Xp22. For the loci on 1p34.3–p36.13 and 7q11, a moderate positive association with positional candidate genes has been demonstrated (perlecan gene, elastin gene, collagen type 1 A2

  2. Epidemiology and genetics of intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Caranci, F., E-mail: ferdinandocaranci@libero.it [Unit of Neuroradiology, Department of Diagnostic Radiology and Radiotherapy, Federico II University, Naples (Italy); Briganti, F., E-mail: frabriga@unina.it [Unit of Neuroradiology, Department of Diagnostic Radiology and Radiotherapy, Federico II University, Naples (Italy); Cirillo, L.; Leonardi, M. [Neuroradiology service, Bellaria Hospital, Bologna (Italy); Muto, M., E-mail: mutomar@tiscali.it [Neuroradiology Service Cardarelli Hospital Naples (Italy)

    2013-10-01

    Intracranial aneurysms are acquired lesions (5–10% of the population), a fraction of which rupture leading to subarachnoid hemorrhage with devastating consequences. Until now, the exact etiology of intracranial aneurysms formation remains unclear. The low incidence of subarachnoid hemorrhage in comparison with the prevalence of unruptured IAs suggests that the vast majority of intracranial aneurysms do not rupture and that identifying those at highest risk is important in defining the optimal management. The most important factors predicting rupture are aneurysm size and site. In addition to ambiental factors (smoking, excessive alcohol consumption and hypertension), epidemiological studies have demonstrated a familiar influence contributing to the pathogenesis of intracranial aneurysms, with increased frequency in first- and second-degree relatives of people with subarachnoid hemorrhage. In comparison to sporadic aneurysms, familial aneurysms tend to be larger, more often located at the middle cerebral artery, and more likely to be multiple. Other than familiar occurrence, there are several heritable conditions associated with intracranial aneurysm formation, including autosomal dominant polycystic kidney disease, neurofibromatosis type I, Marfan syndrome, multiple endocrine neoplasia type I, pseudoxanthoma elasticum, hereditary hemorrhagic telangiectasia, and Ehlers-Danlos syndrome type II and IV. The familial occurrence and the association with heritable conditions indicate that genetic factors may play a role in the development of intracranial aneurysms. Genome-wide linkage studies in families and sib pairs with intracranial aneurysms have identified several loci on chromosomes showing suggestive evidence of linkage, particularly on chromosomes 1p34.3–p36.13, 7q11, 19q13.3, and Xp22. For the loci on 1p34.3–p36.13 and 7q11, a moderate positive association with positional candidate genes has been demonstrated (perlecan gene, elastin gene, collagen type 1 A2

  3. [Congenital anomalies of cerebral artery and intracranial aneurysm].

    Science.gov (United States)

    Nakajima, K; Ito, Z; Hen, R; Uemura, K; Matsuoka, S

    1976-02-01

    It is well known that congenital anomalies such as polycystic kidney, aortic coarctation, Marfan syndrome, Ehler-Danlos syndrome are apt to be complicated by intracranial aneurysms. In this report we attempt to reveal the relation and incidence between cerebrovascular anomalies and intracranial aneurysms. The etiology of aneurysms has been discussed, too. 12 cases of persistent trigeminl artery, 2 cases of persistent hypoglossal artery and 11 cases of fenestration were obtained from 3841 patients who were angiographically examined in our clinic for 5 years. The incidence is 0.31%, 0.05% and 0.29%, respectively. Persistent trigeminal arteries were complicated by 2 cases of intracranial aneurysms and one case of arterivenous malformations (AVM), persistent hypoglossal arteries were complicated by one case of aneurysm, and fenestrations were complicated by 2 cases of aneurysms and one case of AVM. One case of congenital agenesis of right internal carotid artery was obtained which was complicated by aneurysm of anterior communicating artery. Totally, 8 cases of aneurysms and AVM were obtained from 26 cases of cerebrovascular anomalies (incidence 30.8%). On the other hand, thalamic or caudate hemorrhage revealed the highest incidence of complication of intracranial aneurysms among intracerebral hematomas (10.7%). Compared with the incidence of aneurysms between cerebro vascular anomalies (30.8%) and thalamic or caudate hemorrhage (10.7%), the difference is statistically signigicant (P less than 0.05). The cause of intracranial aneurysm has not yet been clarified. But it is well accepted that the defect of tunica media vasorum is most responsible factor as to the occurrence of intracranial aneurysms. We concluded that the genetic error of cerebral vessels including defect of media caused intracranial aneurysms, and this result was supported from the evidence that cerebrovascular anomalies showed statistically high incidence of complication of intracranial aneurysms.

  4. Mycotic Aneurysm of the Aortic Arch

    Directory of Open Access Journals (Sweden)

    Ji Hye Seo

    2014-08-01

    Full Text Available A mycotic aneurysm of the thoracic aorta is rare. We report a case of mycotic aneurysm that developed in the aortic arch. An 86-year-old man was admitted with fever and general weakness. Blood culture yielded methicillin-resistant Staphylococcus aureus. Chest X-ray showed an enlarged aortic arch, and computed tomography scan revealed an aneurysm in the aortic arch. The patient was treated only with antibiotics and not surgically. The size of the aneurysm increased rapidly, resulting in bronchial obstruction and superimposed pneumonia. The patient died of respiratory failure.

  5. Stent-assisted coiling of wide-neck bifurcation aneurysms with a branch incorporated in the aneurysm base: long-term follow-up in 49 patients with 53 aneurysms.

    Science.gov (United States)

    Lubicz, Boris; Morais, Ricardo; Bruyère, Pierre-Julien; Ligot, Noémie; Mine, Benjamin

    2017-06-01

    Wide-neck bifurcation intracranial aneurysms (WNBA) with a branch incorporated in the aneurysm base remain difficult to treat by embolization. We aim to report our long-term follow-up of stent-assisted coiling (SAC) in this subgroup of patients. This study was approved by our local ethical committee. A retrospective review of our prospectively maintained database identified all patients treated in our institution by SAC for a WNBA with a branch incorporated in the aneurysm base. Technical issues, immediate, long-term outcomes were evaluated. Between 2007 and 2015, 49 patients with 53 intracranial aneurysms (IAs) (52 unruptured, 1 ruptured) were identified and successfully treated. No morbidity/mortality occurred. The incorporated branch was preserved in all patients but one who was treated during a vasospasm phase. At the first 6-month imaging control, the branch was patent. Immediate occlusion was near-complete in 11/53 aneurysms (20.8%), neck remnant in 20/53 aneurysms (37.7%), and incomplete in 22/53 aneurysms (41.5%). Available imaging follow-up of 47 IAs, ranging from 3 to 84 months (mean 26 months ± 19.6 months), showed 27 progressive thrombosis (57.4%), 17 stable occlusions (36.2%), 1 minor recanalization (2.1%), and 2 significant recanalizations that were retreated (4.3%). The latest imaging control showed 30 near-complete occlusions (63.8%), 13 neck remnants (27.7%), and 4 incomplete occlusions (8.5%). Stent-assisted coiling is safe and effective for the treatment of WNBA with a branch incorporated in the aneurysm base. Despite poor immediate anatomical results, long-term follow-up shows a high rate of progressive thrombosis achieving adequate and stable occlusion in most patients.

  6. Aneurysmal wall enhancement and perianeurysmal edema after endovascular treatment of unruptured cerebral aneurysms.

    LENUS (Irish Health Repository)

    Su, I-Chang

    2014-06-01

    Perianeurysmal edema and aneurysm wall enhancement are previously described phenomenon after coil embolization attributed to inflammatory reaction. We aimed to demonstrate the prevalence and natural course of these phenomena in unruptured aneurysms after endovascular treatment and to identify factors that contributed to their development.

  7. Computer tomographic phantom

    International Nuclear Information System (INIS)

    Lonn, A.H.R.; Jacobsen, D.R.; Zech, D.J.

    1988-01-01

    A reference phantom for computer tomography employs a flexible member with means for urging the flexible member into contact along the curved surface of the lumbar region of a human patient. In one embodiment, the reference phantom is pre-curved in an arc greater than required. Pressure from the weight of a patient laying upon the reference phantom is effective for straightening out the curvature sufficiently to achieve substantial contact along the lumbar region. The curvature of the reference phantom may be additionally distorted by a resilient pad between the resilient phantom and a table for urging it into contact with the lumbar region. In a second embodiment of the invention, a flexible reference phantom is disposed in a slot in the top of a resilient cushion. The resilient cushion and reference phantom may be enclosed in a flexible container. A partially curved reference phantom in a slot in a resilient cushion is also contemplated. (author)

  8. Isolated iliac artery aneurysms with associated hydronephrosis.

    LENUS (Irish Health Repository)

    O'Driscoll, D

    2012-02-03

    An isolated iliac artery aneurysm is where there is aneurysmal dilatation of one or more branches of the iliac system, with no associated dilatation of the aorta. Such aneurysms are rare and comprise 1% of all intra-abdominal aneurysms. The signs and symptoms of such an aneurysm are influenced by its concealed location within the bony pelvis. Awareness of these special characteristics improves the chances of early diagnosis and proper treatment before possible rupture. We present the clinical and radiological features of three such aneurysms. Ultrasound was the first imaging modality to be performed. Ipsilateral hydronephrosis was demonstrated in each case, this lead to imaging the pelvis and the correct diagnosis. We review the clinical and radiological literature and conclude that the pelvis should be imaged in all cases of unexplained hydronephrosis.

  9. An anatomic risk model to screen post endovascular aneurysm repair patients for aneurysm sac enlargement.

    Science.gov (United States)

    Png, Chien Yi M; Tadros, Rami O; Beckerman, William E; Han, Daniel K; Tardiff, Melissa L; Torres, Marielle R; Marin, Michael L; Faries, Peter L

    2017-09-01

    Follow-up computed tomography angiography (CTA) scans add considerable postimplantation costs to endovascular aneurysm repairs (EVARs) of abdominal aortic aneurysms (AAAs). By building a risk model, we hope to identify patients at low risk for aneurysm sac enlargement to minimize unnecessary CTAs. 895 consecutive patients who underwent EVAR for AAA were reviewed, of which 556 met inclusion criteria. A Probit model was created for aneurysm sac enlargement, with preoperative aneurysm morphology, patient demographics, and operative details as variables. Our final model included 287 patients and had a sensitivity of 100%, a specificity of 68.9%, and an accuracy of 70.4%. Ninety-nine (35%) of patients were assigned to the high-risk group, whereas 188 (65%) of patients were assigned to the low-risk group. Notably, regarding anatomic variables, our model reported that age, pulmonary comorbidities, aortic neck diameter, iliac artery length, and aneurysms were independent predictors of post-EVAR sac enlargement. With the exception of age, all statistically significant variables were qualitatively supported by prior literature. With regards to secondary outcomes, the high-risk group had significantly higher proportions of AAA-related deaths (5.1% versus 1.1%, P = 0.037) and Type 1 endoleaks (9.1% versus 3.2%, P = 0.033). Our model is a decent predictor of patients at low risk for post AAA EVAR aneurysm sac enlargement and associated complications. With additional validation and refinement, it could be applied to practices to cut down on the overall need for postimplantation CTA. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Familial Abdominal Aortic Aneurysm : Clinical Features and Genetics

    NARCIS (Netherlands)

    K.M. van de Luijtgaarden (Koen)

    2016-01-01

    markdownabstractAbstract Cardiovascular disease is the most important cause of death in the world and encompasses occlusive as well as aneurysmal disease. The most common aneurysm in humans is the abdominal aortic aneurysm (AAA). The question is why the aorta dilates in aneurysmal disease and

  11. Traumatic aneurysms of the pericallosal arteries

    International Nuclear Information System (INIS)

    Nakstad, P.; Nornes, H.; Hauge, H.N.

    1986-01-01

    Of a total of 912 operated intracranial aneurysms only three were classified as traumatic (0.3%). They were found in children after severe head trauma and were all located on the pericallosal artery or its branches and not a bifurcations. Shearing forces between the falx, the arteries and the brain at the time of injury are held responsible for the development of these aneurysms. Unlike these traumatic aneurysms, 29 ''spontaneous'' pericallosal aneurysms (3.2%) in adults were located at the bifurcations of the artery. As significantly fewer reports of traumatic aneurysms have been published during the last decade than before 1976, it is suggested that some might have been overlooked as a consequence of CT replacing cerebral angiography in the neuroradiological evaluation of severe head injury. This possibility should be kept in mind, especially when dealing with children after head injury and when CT scans indicate brain damage around the falx. The possibility of overlooking traumatic pericallosal aneurysms is described by other authors and discussed further in this paper. (orig.)

  12. Bilateral giant femoropopliteal artery aneurysms: a case report

    Directory of Open Access Journals (Sweden)

    Perdikides Theodossios P

    2008-04-01

    Full Text Available Abstract Introduction Popliteal artery aneurysms are the most common peripheral arterial aneurysms, and are frequently bilateral. Acute limb ischemia, rupture and compression phenomena can complicate these aneurysms when the diameter exceeds 2 cm. Case Presentation We report an 82-year-old male patient with two giant femoropopliteal aneurysms, 10.5 and 8.5 cm diameters, managed in our institution. Both aneurysms were resected and a polytetrafluoroethylene (PTFE femoropopliteal interposition graft was placed successfully. Management and literature review are discussed. Conclusion We believe this is the first report in the medical literature of bilateral giant femoropopliteal aneurysms.

  13. Dose distribution in organs: patient-specific phantoms versus reference phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, I.V.B., E-mail: isabelle.lacerda@ufpe.br [Universidade Federal de Pernambuco (UFPE), Recife (Brazil); Vieira, J.W. [Instituto Federal de Pernambuco (IFPE), Recife (Brazil); Oliveira, M.L.; Lima, F.R.A. [Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE/CNEN-PB), Recife (Brazil)

    2017-07-01

    Discrepancies between ICRP phantoms and real patients lead to disparities on patient-dose estimations. This paper aims to compare distribution of dose in organs of male/female specific-phantoms and ICRP reference phantoms. The absorbed dose estimation was performed using the EGSnrc Monte Carlo code and a parallel source algorithm. In this work were used a patient-specific phantom for a man (1.73m/70.3kg) and another for a woman (1.63m/60.3kg) and the male and female ICRP reference phantoms. The comparison of the absorbed dose from each phantom gender was performed using the relative error. The results were expressed in terms of conversion coefficients to brain, lungs, liver and kidneys. The greatest absolute relative error between the organs of the patient-specific phantom and the reference phantom was 22.92% in the liver and 62.84% in the kidneys, respectively for man and woman. There are errors that cannot be disregarded. This paper shows the need for a specific study for each patient or for the population of each country, since there are different body types, which affects the distribution of the organ doses. (author)

  14. Dose distribution in organs: patient-specific phantoms versus reference phantoms

    International Nuclear Information System (INIS)

    Lacerda, I.V.B.; Vieira, J.W.; Oliveira, M.L.; Lima, F.R.A.

    2017-01-01

    Discrepancies between ICRP phantoms and real patients lead to disparities on patient-dose estimations. This paper aims to compare distribution of dose in organs of male/female specific-phantoms and ICRP reference phantoms. The absorbed dose estimation was performed using the EGSnrc Monte Carlo code and a parallel source algorithm. In this work were used a patient-specific phantom for a man (1.73m/70.3kg) and another for a woman (1.63m/60.3kg) and the male and female ICRP reference phantoms. The comparison of the absorbed dose from each phantom gender was performed using the relative error. The results were expressed in terms of conversion coefficients to brain, lungs, liver and kidneys. The greatest absolute relative error between the organs of the patient-specific phantom and the reference phantom was 22.92% in the liver and 62.84% in the kidneys, respectively for man and woman. There are errors that cannot be disregarded. This paper shows the need for a specific study for each patient or for the population of each country, since there are different body types, which affects the distribution of the organ doses. (author)

  15. Endovascular coil embolization for anterior choroidal artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byung Moon; Chung, Eun Chul [Sungkyunkwan University School of Medicine, Department of Radiology, Kangbuk Samsung Hospital, Seoul (Korea); Kim, Dong Ik; Kim, Dong Joon; Suh, Sang Hyun [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea); Kim, Sun Yong [Ajou University College of Medicine, Department of Radiology, Suwon (Korea); Shin, Yong Sam [Ajou University College of Medicine, Department of Neurosurgery, Suwon (Korea); Park, Sung Il [Soonchunhyang University College of Medicine, Department of Radiology, Bucheon Hospital, Bucheon (Korea); Choi, Chun Sik; Won, Yu.Sam [Sungkyunkwan University School of Medicine, Department of Neurosurgery, Kangbuk Samsung Hospital, Seoul (Korea)

    2008-03-15

    We retrospectively evaluated the ischemic complications related to the anterior choroidal artery (AChA) and clinical outcome after coiling of AChA aneurysms. We included 37 patients (27 with subarachnoid hemorrhage, 10 without) harboring 38 AChA aneurysms (23 ruptured, 15 unruptured) who were treated by coiling at four institutions. Ischemic complications related to the AChA and clinical outcomes were retrospectively evaluated. Intraprocedural transient AChA occlusion occurred in five aneurysms, all of which had AChA incorporated into the aneurysm neck. Two of the five patients suffered postprocedural transient contralateral hemiparesis, but recovered completely. The remaining three patients had no postprocedural symptoms. Incidence of transient AChA occlusion was significantly higher in those aneurysms in which the AChA was incorporated into aneurysm neck (group 2) than in those in which the AChA was not incorporated (group 1). Of the 37 patients, 31 (83.8%) had good recoveries (modified Rankin scale score 0-2). Two patients died from the consequences of subarachnoid hemorrhage. During follow-up for a mean of 27 months (range 4-72 months), none of the 35 living patients re-bled. A total of 29 aneurysms in 28 patients were followed-up angiographically. Recurrences were found in 5 of the 29 aneurysms during follow-up (mean 18 months, range 6-45 months). Re-embolization achieved near complete occlusion of two recurrent aneurysms, both of which were still stable at the time of the next two follow-up angiographies. The other three recurrent aneurysms were not retreated due to the small size of the recurrences. Coiling of AChA aneurysms resulted in good outcomes without AChA-related permanent ischemic complications. Transient AChA occlusion, potentially associated with ischemic complications, was significantly more frequent in the aneurysm in which the AChA was incorporated into the aneurysm neck. (orig.)

  16. Endovascular Aortic Aneurysm Repair for Abdominal Aortic Aneurysm: Single Center Experience in 122 Patients

    International Nuclear Information System (INIS)

    Lee, Yun Young; Song, Jang Hyeon; Kim, Yong Tae; Yim, Nam Yeol; Kim, Jae Kyu; Lee, Ho Kyun; Choi, Soo Jin Na; Chung, Sang Young; Kim, Soo Hyun; Chang, Nam Kyu

    2013-01-01

    To analyze a single center experience of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms. Results of 122 patients who underwent EVAR were analyzed, retrospectively. Sex, age, aneurysmal morphology, hostile neck anatomy, preprocedural and postprocedural sac-diameter, technical and clinical success, postprocedural complication and need of additional procedure were analyzed. A total of 111 male and 11 female patients were included. Morphology of the aneurysms was as follows: fusiform (n = 108), saccular (n = 3) and ruptured type (n = 11). Sixty-four patients had hostile neck anatomy. The preprocedural mean sac-diameter was 52.4 mm. Postprocedural sac-diameter was decreased or stable in 110 patients (90.2%) and increased in 8 patients (6.6%). Technical success rate was 100% and clinical success rate was 86.1%. Fifty-one patients showed endoleak (41.8%) and 15 patients (12.3%) underwent secondary intervention due to type I endoleak (n = 4), type II endoleak (n = 4) and stent-graft thrombosis (n = 7). EVAR is a safe and effective therapy for abdominal aortic aneurysm, and it has high technical success and clinical success rate, and low complication rate.

  17. Extra-anatomic endovascular repair of an abdominal aortic aneurysm with a horseshoe kidney supplied by the aneurysmal aorta.

    Science.gov (United States)

    Rey, Jorge; Golpanian, Samuel; Yang, Jane K; Moreno, Enrique; Velazquez, Omaida C; Goldstein, Lee J; Chahwala, Veer

    2015-07-01

    Abdominal aortic aneurysm complicated by a horseshoe kidney (HSK, fused kidney) represents a unique challenge for repair. Renal arteries arising from the aneurysmal aorta can further complicate intervention. Reports exist describing the repair of these complex anatomies using fenestrated endografts, hybrid open repairs (debranching), and open aneurysmorrhaphy with preservation of renal circulation. We describe an extra-anatomic, fully endovascular repair of an abdominal aortic aneurysm with a HSK partially supplied by a renal artery arising from the aneurysm. We successfully applied aortouni-iliac endografting, femorofemoral bypass, and retrograde renal artery perfusion via the contralateral femoral artery to exclude the abdominal aortic aneurysm and preserve circulation to the HSK. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Radiological image interpretation for hematoma and small tumors simulated in a head and neck phantom

    International Nuclear Information System (INIS)

    Thompson, Larissa; Campos, Tarcisio Passos Ribeiro

    2009-01-01

    Subarachnoidal hemorrhages (HSA) are caused by aneurysms and their symptom usually becomes evident after a rupture. Nevertheless, there are situations in which the aneurysms compress a nerve or produce a bleed before the rupture happens, as consequence one alert signal like headache occurs. It, often occurs after minutes or weeks previous the major rupture. The main goal is to prevent a massive hemorrhage. Thus the Computer Tomography (CT) scan of skull provides a basic and specific function: to reveal the position where the hemorrhage was produced, guiding to a additional medical procedures. On the other hand, CT does not prevent the cerebral tumor development, but precise diagnostic for some symptoms such as vomits, nauseas, epileptic attacks, weakness in arms or legs, require this image protocol. CT has its fundamental importance to tumor detection. Indeed CT reveals its importance in the tumor early diagnosis. Specialized training in CT analysis shall be done. Ahead of a precise diagnosis to manager an early intervention, a CT diagnostic training is suitable for a favorable prognostic. In this context, focusing on propose of radiological inquires; a head and neck phantom will be used to simulate hematomas and cerebral tumors. Images of CT of skull will be used to identify these lesions physically implanted in phantom. The radiological response will be analyzed with the purpose of validation of the skull's CT diagnosis, for a double blind test. The diagnostic with non contrast CT shows only higher 5mm diameter subjects (tumors) identified by the double blind test. Hemorrhage is identified by only the administrator (single-blind test). As conclusion, the author's launches the hypothesis that this object simulator shall provide assistance for specialized training on pathology interpretation on radiological images. (author)

  19. Safety and efficacy of aneurysm treatment with WEB

    DEFF Research Database (Denmark)

    Pierot, Laurent; Costalat, Vincent; Moret, Jacques

    2016-01-01

    OBJECT WEB is an innovative intrasaccular treatment for intracranial aneurysms. Preliminary series have shown good safety and efficacy. The WEB Clinical Assessment of Intrasaccular Aneurysm Therapy (WEBCAST) trial is a prospective European trial evaluating the safety and efficacy of WEB in wide......-neck bifurcation aneurysms. METHODS Patients with wide-neck bifurcation aneurysms for which WEB treatment was indicated were included in this multicentergood clinical practices study. Clinical data including adverse events and clinical status at 1 and 6 months were collected and independently analyzed by a medical....... RESULTS Ten European neurointerventional centers enrolled 51 patients with 51 aneurysms. Treatment with WEB was achieved in 48 of 51 aneurysms (94.1%). Adjunctive implants (coils/stents) were used in 4 of 48 aneurysms (8.3%). Thromboembolic events were observed in 9 of 51 patients (17.6%), resulting...

  20. Interventional procedures of the isolated iliac arterial aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Ohm, Joon Young [The Catholic Univ. of Korea College of Medicine, Bucheon (Korea, Republic of); Shin, Byung Seok; Ahn, Moon Sang [Chungnam National Univ. Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dankook Univ. Hospital, Cheonan (Korea, Republic of); Kim, Ho Jun [Konyang Univ. Hospital, Daejeon (Korea, Republic of)

    2012-05-15

    To report the results of treatment isolated iliac arterial aneurysms by interventional procedures. Over a period of 5 years, 7 isolated iliac artery aneurysms (4 in the common iliac artery, 3 in the internal iliac artery) in 7 patients (3 women, 4 men; mean age, 65.7 years) were treated using interventional procedures. The mean aneurysm size was 35 mm (range, 30-45 mm). The common iliac aneurysms were treated using a unilateral stent graft (2 balloon expandable, 2 self expandable) with coil embolization of the internal iliac artery (n = 3), except for 1 aneurysm that ruptured. Coil embolization alone was performed for aneurysms involving only the internal iliac artery (n = 3). All patients were treated successfully, except for 1 with an initial remnant of type 2 endoleak. There were no perioperative complications. No leakage or complication occurred at the mean follow up of 14 months (range 2-29 months). One patient with a ruptured aneurysm died of multi organ failure during the follow up period. Three aneurysms had decreased in size on follow up CT. Interventional procedures with stent grafting and coil embolization are safe and effective treatments for isolated iliac artery aneurysms.

  1. Advances in the imaging of cerebral aneurysm inflammation

    Directory of Open Access Journals (Sweden)

    Michael R Levitt

    2015-06-01

    Full Text Available Cerebral aneurysm formation, growth and rupture are thought to be the result of a complex interaction between cerebrovascular hemodynamics and pathobiology. Recently, new evidence has emerged regarding the role of inflammation in the walls of cerebral aneurysms. Noninvasive methods to characterize the degree of inflammation in aneurysms could enable clinicians to estimate the risk of future aneurysm growth and rupture, influencing treatment. This review examines emerging techniques of imaging inflammatory biomarkers in cerebral aneurysms.

  2. Carotid artery aneurysm resulting in myxedema coma

    Directory of Open Access Journals (Sweden)

    Elizabeth M. Lamos

    2015-06-01

    Full Text Available Intra-sellar aneurysms are a rare, but important consideration when evaluating pituitary masses. Identification of aneurysms is critical to appropriate treatment and avoiding perilous consequences. These vascular aneurysms can result in severe endocrine dysfunction due to mass effect, stripping of the vascular supply to the pituitary, or hemorrhage. Here we describe a novel case of spontaneous myxedema coma and pituitary apoplexy secondary to a large internal carotid artery aneurysm.

  3. The pretzel sign: angiographic pattern of tortuous intra-aneurysmal blood flow in a giant serpentine aneurysm.

    LENUS (Irish Health Repository)

    Fanning, N F

    2012-02-03

    Giant serpentine aneurysms (GSAs) form a specific subgroup of giant cerebral aneurysms that have pathognomonic angiographic features. We report the angiographic findings of a GSA demonstrating a striking convoluted dynamic flow pattern, which we have called the \\'pretzel sign\\'. The aneurysm was successfully treated by permanent occlusion of the parent vessel using a detachable balloon. GSAs should be identified prior to treatment in view of their particular management requirements.

  4. The pathogenesis shared between abdominal aortic aneurysms and intracranial aneurysms: a microarray analysis.

    Science.gov (United States)

    Wang, Wen; Li, Hao; Zhao, Zheng; Wang, Haoyuan; Zhang, Dong; Zhang, Yan; Lan, Qing; Wang, Jiangfei; Cao, Yong; Zhao, Jizong

    2018-04-01

    Abdominal aortic aneurysms (AAAs) and intracranial saccular aneurysms (IAs) are the most common types of aneurysms. This study was to investigate the common pathogenesis shared between these two kinds of aneurysms. We collected 12 IAs samples and 12 control arteries from the Beijing Tiantan Hospital and performed microarray analysis. In addition, we utilized the microarray datasets of IAs and AAAs from the Gene Expression Omnibus (GEO), in combination with our microarray results, to generate messenger RNA expression profiles for both AAAs and IAs in our study. Functional exploration and protein-protein interaction (PPI) analysis were performed. A total of 727 common genes were differentially expressed (404 was upregulated; 323 was downregulated) for both AAAs and IAs. The GO and pathway analyses showed that the common dysregulated genes were mainly enriched in vascular smooth muscle contraction, muscle contraction, immune response, defense response, cell activation, IL-6 signaling and chemokine signaling pathways, etc. The further protein-protein analysis identified 35 hub nodes, including TNF, IL6, MAPK13, and CCL5. These hub node genes were enriched in inflammatory response, positive regulation of IL-6 production, chemokine signaling pathway, and T/B cell receptor signaling pathway. Our study will gain new insight into the molecular mechanisms for the pathogenesis of both types of aneurysms and provide new therapeutic targets for the patients harboring AAAs and IAs.

  5. Successful Endovascular Treatment of a Left Common Carotid Artery Aneurysm Following Failed Surgery of a Right Common Carotid Artery Aneurysm

    International Nuclear Information System (INIS)

    Cil, Barbaros E.; Ucar, Ibrahim; Ozsoy, Fatma; Arat, Anil; Yorgancioglu, Cem; Boeke, Erkmen

    2005-01-01

    Aneurysm of the common carotid artery is a rare and serious disease requiring prompt treatment in order to avoid neurologic complications. A 39-year-old man presented with voice impairment and a pulsatile mass at the right side of his neck and was found by color Doppler examination to have bilateral common carotid artery aneurysms of unknown origin. The right-sided large aneurysm was treated with placement of an 8 mm interposition Gore-Tex graft between the right common and internal carotid arteries. The surgical graft thrombosed 7 days after the surgery but the left-sided aneurysm was successfully treated by a Jostent peripheral stent-graft. Color Doppler examination showed a patent stent and no filling of the aneurysm on his first and sixth-month follow-up. Bilateral common carotid artery aneurysm is an exceptionally unusual condition and endovascular treatment of carotid artery aneurysms with covered stents may become an effective treatment alternative for these lesions

  6. A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Werner; Kuehne, Dietmar [Alfried Krupp Hospital, Department of Radiology and Neuroradiology, Essen (Germany); Bendszus, Martin; Solymosi, Laszlo [University of Wuerzburg, Department of Neuroradiology, Wuerzburg (Germany); Kis, Bernhard [University of Duisburg-Essen, Research Unit, Rheinische Kliniken Essen, Department of Psychiatry and Psychotherapy, Essen (Germany); Boulanger, Thierry [Centre Hospitalier of Luxembourg, Service of Neuroradiology, Luxembourg (Luxembourg)

    2007-07-15

    We report the results of a prospective clinical study using a new self-expanding nitinol stent (Enterprise) designed for the treatment of wide-necked intracranial aneurysms. We treated 31 saccular, wide-necked intracranial aneurysms in 30 patients. Ten aneurysms had recanalized after prior endovascular treatment without a stent, and 21 aneurysms had not been treated before. Stent deployment was successful in all procedures. Additional coil embolization was performed in all aneurysms. Initial complete angiographic occlusion was achieved in 6 aneurysms, a neck remnant was left in 18 aneurysms and there were 7 residual aneurysms. Angiographic follow-up examinations of 30 lesions after 6 months demonstrated 15 complete occlusions, 8 neck remnants and 7 residual aneurysms. One patient refused the 6-month angiographic follow-up. Spontaneous occlusion of the aneurysm had occurred in 14 patients, and 6 aneurysms showed recanalization. Four of these residual aneurysms were retreated. At the 6-month follow-up, 29 parent arteries were unaffected, whereas two parent vessels demonstrated minor asymptomatic narrowing at the stent site. Two patients experienced one or more possible or probable device-related serious adverse events during the 6-month follow-up period. There was no procedural morbidity or mortality at 6 months after the procedure. The reported results demonstrated the safety and feasibility of the Cordis Neurovascular Enterprise stent in the treatment of wide-necked intracranial aneurysms. Initial clinical and angiographic results are favorable. (orig.)

  7. Advances in open microsurgery for cerebral aneurysms.

    Science.gov (United States)

    Davies, Jason M; Lawton, Michael T

    2014-02-01

    Endovascular techniques introduced strong extrinsic forces that provoked reactive changes in aneurysm surgery. Microsurgery has become less invasive, more appealing to patients, lower risk, and efficacious for complex aneurysms, particularly those unfavorable for or failing endovascular therapy. To review specific advances in open microsurgery for aneurysms. A university-based, single-surgeon practice was examined for the use of minimally invasive craniotomies, surgical management of recurrence after coiling, the use of intracranial-intracranial bypass techniques, and cerebrovascular volume-outcome relationships. The mini-pterional, lateral supraorbital, and orbital-pterional craniotomies are minimally invasive alternatives to standard craniotomies. Mini-pterional and lateral supraorbital craniotomies were used in one-fourth of unruptured patients, increasing from 22% to 28%, whereas 15% of patients underwent orbital-pterional craniotomies and trended upward from 11% to 20%. Seventy-four patients were treated for coil recurrences (2.3% of all aneurysms) with direct clip occlusion (77%), clip occlusion after coil extraction (7%), or parent artery occlusion with bypass (16%). Intracranial-intracranial bypass (in situ bypass, reimplantation, reanastomosis, and intracranial grafts) transformed the management of giant aneurysms and made the surgical treatment of posterior inferior cerebellar artery aneurysms competitive with endovascular therapy. Centralization maximized the volume-outcome relationships observed with clipping. Aneurysm microsurgery has embraced minimalism, tailoring the exposure to the patient's anatomy with the smallest possible craniotomy that provides adequate exposure. The development of intracranial-intracranial bypasses is an important advancement that makes microsurgery a competitive option for complex and recurrent aneurysms. Trends toward centralizing aneurysm surgery in tertiary centers optimize results achievable with open microsurgery.

  8. Idiopathic subvalvular aortic aneurysm masquerading as acute coronary syndrome.

    Science.gov (United States)

    Natarajan, Balaji; Ramanathan, Sundar; Subramaniam, Natarajan; Janardhanan, Rajesh

    2016-09-02

    Subvalvular aneurysms are the least common type of left ventricular (LV) aneurysms and can be fatal. Subaortic LV aneurysms are much rarer than submitral LV aneurysms and mostly reported in infancy. They can be congenital or acquired secondary to infections, cardiac surgery or trauma. Here, we report a unique presentation of a large, idiopathic subaortic aneurysm in an adult masquerading as an acute coronary syndrome. Diagnosis was made with the help of a CT aortography. Aneurysm was surgically resected with good results. This case highlights the clinical presentation and management of subaortic aneurysms, an important differential for congenital aortic malformations. 2016 BMJ Publishing Group Ltd.

  9. Extracranial internal carotid artery aneurysm: case illustration

    Directory of Open Access Journals (Sweden)

    Zenteno Marco

    2017-12-01

    Full Text Available Extracranial internal carotid artery aneurysms (EICAA are uncommon lesion. These aneurysms can be classified as true or false aneurysms, atherosclerotic, dysplastic, infectious, posttraumatic and iatrogenic aneurysms. The most common presentation is central neurologic dysfunction, either a stroke or a transient ischemic attack. The rupture of these aneurysms can lead to severely impairment and can affect the quality of life of the patients or even may lead to death. Management of these lesions is required in most cases to prevent complications, however there is no treatment guideline or expert consensus for the management. We present a case of an unusual EICAA, associated with kinking of the affected vessel and review the literature.

  10. Phantom position dependence

    International Nuclear Information System (INIS)

    Thorson, M.R.; Endres, G.W.R.

    1981-01-01

    Sensitivity of the Hanford dosimeter response to its position relative to the phantom and the neutron source has always been recognized. A thorough investigation was performed to quantify dosimeter response according to: (a) dosimeter position on phantom, (b) dosimeter distance from phantom, and (c) angular relationship of dosimeter relative to neutron source and phantom. Results were obtained for neutron irradiation at several different energies

  11. Hemodynamics Modeling and Simulation of Anterior Communicating Artery Aneurysms

    Directory of Open Access Journals (Sweden)

    Jianjun Li

    2014-07-01

    Full Text Available It is a general agreement that hemodynamics plays very important role in the initiation, growth, and rupture of cerebral aneurysms and hemodynamics in the anterior communicating artery aneurysms is considered the most complex in all cerebral aneurysms and it is difficult to find some reasonable relationship between the hemodynamics parameters and the rupture risk. In this paper, the 3D geometries of four anterior communicating artery aneurysms were generated from the CTA data and the computational models with bilateral feeding arteries for the four aneurysms were constructed. The blood flow was simulated by computational fluid dynamics software and the hemodynamics parameters such as velocity, wall shear stress, and oscillatory shear index were calculated. The following results were observed: one of the four models only needs the left feeding artery; the max normalized wall shear stress locates at the aneurysmal neck of the largest aneurysm; the max oscillatory shear index locates at the aneurysmal sac of the largest aneurysm. The conclusion was drawn that the anterior communicating artery aneurysm has higher rupture risk from the hemodynamics viewpoint if the max wall shear stress locates at the neck and the max oscillatory shear index locates at the dome.

  12. Intracranial Aneurysms of Neuro-Ophthalmologic Relevance.

    Science.gov (United States)

    Micieli, Jonathan A; Newman, Nancy J; Barrow, Daniel L; Biousse, Valérie

    2017-12-01

    Intracranial saccular aneurysms are acquired lesions that often present with neuro-ophthalmologic symptoms and signs. Recent advances in neurosurgical techniques, endovascular treatments, and neurocritical care have improved the optimal management of symptomatic unruptured aneurysms, but whether the chosen treatment has an impact on neuro-ophthalmologic outcomes remains debated. A review of the literature focused on neuro-ophthalmic manifestations and treatment of intracranial aneurysms with specific relevance to neuro-ophthalmologic outcomes was conducted using Ovid MEDLINE and EMBASE databases. Cavernous sinus aneurysms were not included in this review. Surgical clipping vs endovascular coiling for aneurysms causing third nerve palsies was compared in 13 retrospective studies representing 447 patients. Complete recovery was achieved in 78% of surgical patients compared with 44% of patients treated with endovascular coiling. However, the complication rate, hospital costs, and days spent in intensive care were reported as higher in surgically treated patients. Retrospective reviews of surgical clipping and endovascular coiling for all ocular motor nerve palsies (third, fourth, or sixth cranial nerves) revealed similar results of complete resolution in 76% and 49%, respectively. Improvement in visual deficits related to aneurysmal compression of the anterior visual pathways was also better among patients treated with clipping than with coiling. The time to treatment from onset of visual symptoms was a predictive factor of visual recovery in several studies. Few reports have specifically assessed the improvement of visual deficits after treatment with flow diverters. Decisions regarding the choice of therapy for intracranial aneurysms causing neuro-ophthalmologic signs ideally should be made at high-volume centers with access to both surgical and endovascular treatments. The status of the patient, location of the aneurysm, and experience of the treating physicians

  13. The influence of neck thrombus on clinical outcome and aneurysm morphology after endovascular aneurysm repair

    NARCIS (Netherlands)

    F.M.V. Bastos Gonçalves (Frederico); H.J.M. Verhagen (Hence); K. Chinsakchai (Khamin); J.W. van Keulen (Jasper); M.T. Voûte (Michiel); H.J.A. Zandvoort (Herman); F.L. Moll (Frans); J.A. van Herwaarden (Joost)

    2012-01-01

    textabstractObjective: This study investigated the influence of significant aneurysm neck thrombus in clinical and morphologic outcomes after endovascular aneurysm repair (EVAR). Methods: The patient population was derived from a prospective EVAR database from two university institutions in The

  14. Recurrence of ICA-PCoA aneurysms after neck clipping.

    Science.gov (United States)

    Sakaki, T; Takeshima, T; Tominaga, M; Hashimoto, H; Kawaguchi, S

    1994-01-01

    Between 1975 and 1992, 2211 patients underwent aneurysmal neck clipping at the Nara Medical University clinic and associated hospitals. The aneurysm in 931 of these patients was situated at the junction of the internal carotid artery (ICA) and posterior communicating artery (PCoA). Seven patients were readmitted 4 to 17 years after the first surgery because of regrowth and rupture of an ICA-PCoA aneurysmal sac that had arisen from the residual neck. On angiograms obtained following aneurysmal neck clipping, a large primitive type of PCoA was demonstrated in six patients and a small PCoA in one. A small residual aneurysm was confirmed in only two patients and angiographically complete neck clipping in five. Recurrent ICA-PCoA aneurysms were separated into two types based on the position of the old clip in relation to the new growth. Type 1 aneurysms regrow from the entire neck and balloon eccentrically. In this type, it is possible to apply the clip at the neck as in conventional clipping for a ruptured aneurysm. Type 2 includes aneurysms in which the proximal portion of a previous clip is situated at the corner of the ICA and aneurysmal neck and the distal portion on the enlarged dome of the aneurysm, because the sac is regrowing from a portion of the residual neck. In this type of aneurysm, a Sugita fenestrated clip can occlude the residual neck, overriding the old clip. Classifying these aneurysms into two groups is very useful from a surgical point of view because it is possible to apply a new clip without removing the old clip, which was found to be adherent to surrounding tissue.

  15. The Effect of Hemodynamics on Cerebral Aneurysm Morphology

    Science.gov (United States)

    Metcalfe, Ralph; Mantha, Aishwarya; Karmonik, Christof; Strother, Charles

    2004-11-01

    One of the difficulties in applying principles of hemodynamics to the study of blood flow in aneurysms are the drastic variations in possible shape of both the aneurysms and the parent arteries in the region of interest. We have taken data from three para-opthalmic internal carotid artery aneurysms using 3D-digital subtraction angiography (3D-DSA) and performed CFD simulations of steady and unsteady flows through the three different cases using the same pressure gradients and pulsatile flow waveforms (based on the Ku model for flow through the Carotid bifurcation). We have found that the total pressure differential within the aneurysms is consistent with the direction of flow, and that the dynamic pressure gradient within the aneurysm is very small compared with the static pressure variations. Wall shear stresses were highest near regions of sharp arterial curvature, but always remained low inside the aneurysm. These results suggest a more complex role for hemodynamics in aneurysm generation, growth and rupture.

  16. Morphological and clinical risk factors for posterior communicating artery aneurysm rupture.

    Science.gov (United States)

    Matsukawa, Hidetoshi; Fujii, Motoharu; Akaike, Gensuke; Uemura, Akihiro; Takahashi, Osamu; Niimi, Yasunari; Shinoda, Masaki

    2014-01-01

    Recent studies have shown that posterior circulation aneurysms, specifically posterior communicating artery (PCoA) aneurysms, are more likely to rupture than other aneurysms. To date, few studies have investigated the factors contributing to PCoA aneurysm rupture. The authors aimed to identify morphological and clinical characteristics predisposing to PCoA aneurysm rupture. The authors retrospectively reviewed 134 consecutive patients with PCoA aneurysms managed at their facility between July 2003 and December 2012. The authors divided patients into groups of those with aneurysmal rupture (n = 39) and without aneurysmal rupture (n = 95) and compared morphological and clinical characteristics. Morphological characteristics were mainly evaluated by 3D CT angiography and included diameter of arteries (anterior cerebral artery, middle cerebral artery, and internal carotid artery), size of the aneurysm, dome-to-neck ratio, neck direction of the aneurysmal dome around the PCoA (medial, lateral, superior, inferior, and posterior), aneurysm bleb formation, whether the PCoA was fetal type, and the existence of other intracranial unruptured aneurysm(s). Patients with ruptured PCoA aneurysms were significantly younger (a higher proportion were PCoA aneurysms showed a lateral direction of the aneurysmal dome around the PCoA, had bleb formation, and the aneurysm was > 7 mm in diameter and/or the dome-to-neck ratio was > 2.0. Multivariate logistic regression analysis showed age PCoA (OR 6.7, p = 0.0001), and bleb formation (OR 11, p PCoA aneurysm rupture. The present results demonstrated that lateral projection of a PCoA aneurysm may be related to rupture.

  17. Microneurosurgical management of anterior choroid artery aneurysms.

    Science.gov (United States)

    Lehecka, Martin; Dashti, Reza; Laakso, Aki; van Popta, Jouke S; Romani, Rossana; Navratil, Ondrej; Kivipelto, Leena; Kivisaari, Riku; Foroughi, Mansoor; Kokuzawa, Jouji; Lehto, Hanna; Niemelä, Mika; Rinne, Jaakko; Ronkainen, Antti; Koivisto, Timo; Jääskelainen, Juha E; Hernesniemi, Juha

    2010-05-01

    Anterior choroid artery aneurysms (AChAAs) constitute 2%-5% of all intracranial aneurysms. They are usually small, thin walled with one or several arteries originating at their base, and often associated with multiple aneurysms. In this article, we review the practical microsurgical anatomy, the preoperative imaging, surgical planning, and the microneurosurgical steps in the dissection and the clipping of AChAAs. This review, and the whole series on intracranial aneurysms (IAs), are mainly based on the personal microneurosurgical experience of the senior author (J.H.) in two Finnish centers (Helsinki and Kuopio) that serve, without patient selection, the catchment area in Southern and Eastern Finland. These two centers have treated more than 10,000 patients with IAs since 1951. In the Kuopio Cerebral Aneurysm Database of 3005 patients with 4253 IAs, 831 patients (28%) had altogether 980 internal carotid artery (ICA) aneurysms, of whom 95 patients had 99 (2%) AChAAs. Ruptured AChAAs, found in 39 patients (41%), with median size of 6 mm (range = 2-19 mm), were associated with intracerebral hematoma (ICH) in only 1 (3%) patient. Multiple aneurysms were seen in 58 (61%) patients. The main difficulty in microneurosurgical management of AChAAs is to preserve flow in the anterior choroid artery originating at the base and often attached to the aneurysm dome. This necessitates perfect surgical strategy based on preoperative knowledge of 3 dimensional angioarchitecture and proper orientation during the microsurgical dissection. Copyright © 2010 Elsevier Inc. All rights reserved.

  18. Postprocedural Monitoring of Cerebral Aneurysms

    International Nuclear Information System (INIS)

    Kaehaerae, V.

    2006-01-01

    The treatment of intracranial aneurysms has been revolutionized since the introduction of electrolytically detachable platinum coils in 1991. Since this basic innovation, many refinements of the embolic materials and techniques have emerged. Today, in Europe, half of all aneurysms are treated endoarterially and this share is growing. The reassuring results of the International Subarachnoid Aneurysm Trial (ISAT) have changed the treatment strategy from neurosurgical clipping to embolization. However, the role of these alternative modes of treatment varies between institutions and countries. An angiographic follow-up pattern after endovascular treatment has remained largely undefined and in the same way there has been much diversity in applying alternative imaging modalities. Although some institutions continue to perform intervalled digital subtraction angiography, magnetic resonance angiography has assumed an increasing role. A vast majority of patients with embolized aneurysms are eligible to be monitored solely by non-contrast three-dimensional time-of-flight technique

  19. Surgical approach to posterior inferior cerebellar artery aneurysms.

    Science.gov (United States)

    La Pira, Biagia; Sturiale, Carmelo Lucio; Della Pepa, Giuseppe Maria; Albanese, Alessio

    2018-02-01

    The far-lateral is a standardised approach to clip aneurysms of the posterior inferior cerebellar artery (PICA). Different variants can be adopted to manage aneurysms that differ in morphology, topography, ruptured status, cerebellar swelling and surgeon preference. We distinguished five paradigmatic approaches aimed to manage aneurysms that are: proximal unruptured; proximal ruptured requiring posterior fossa decompression (PFD); proximal ruptured not requiring PFD; distal unruptured; distal ruptured. Preoperative planning in the setting of PICA aneurysm surgery is of paramount importance to perform an effective and safe procedure, to ensure an adequate PFD and optimal proximal control before aneurysm manipulation.

  20. Complications of endovascular treatment of cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Orrù, Emanuele, E-mail: surgeon.ema@gmail.com [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Roccatagliata, Luca, E-mail: lroccatagliata@neurologia.unige.it [Neuroradiology Department, IRCCS San Martino University Hospital and IST, Largo Rosanna Benzi 10, Genoa 16132 (Italy); Department of Health Sciences (DISSAL), University of Genoa (Italy); Cester, Giacomo, E-mail: giacomo.cester@sanita.padova.it [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Causin, Francesco, E-mail: francesco.causin@sanita.padova.it [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Castellan, Lucio, E-mail: lucio.castellan@hsanmartino.it [Neuroradiology Department, IRCCS San Martino University Hospital and IST, Largo Rosanna Benzi 10, Genoa 16132 (Italy)

    2013-10-01

    The number of neuroendovascular treatments of both ruptured and unruptured aneurysms has increased substantially in the last two decades. Complications of endovascular treatments of cerebral aneurysms are rare but can potentially lead to acute worsening of the neurological status, to new neurological deficits or death. Some of the possible complications, such as vascular access site complications or systemic side effects associated with contrast medium (e.g. contrast medium allergy, contrast induced nephropathy) can also be encountered in diagnostic angiography. The most common complications of endovascular treatment of cerebral aneurysms are related to acute thromboembolic events and perforation of the aneurysm. Overall, the reported rate of thromboembolic complications ranges between 4.7% and 12.5% while the rate of intraprocedural rupture of cerebral aneurysms is about 0.7% in patients with unruptured aneurysms and about 4.1% in patients with previously ruptured aneurysms. Thromboembolic and hemorrhagic complications may occur during different phases of endovascular procedures and are related to different technical, clinical and anatomic reasons. A thorough knowledge of the different aspects of these complications can reduce the risk of their occurrence and minimize their clinical sequelae. A deep understanding of complications and of their management is thus part of the best standard of care.

  1. Computed tomographic diagnosis of pulmonary artery aneurysm

    International Nuclear Information System (INIS)

    Maeno, Kouji; Kontani, Kazuhiro; Ito, Makoto; Sakurai, Noboru; Sawada, Taisei; Fukeda, Yasuhiko; Takata, Shigeo; Ikeda, Takayuki; Hattori, Nobu.

    1986-01-01

    Pulmonary artery aneurysms are rare lesions. Clagett et al reported that one aneurysm of the pulmonary artery may be found in approximately 14,000 necropsies. We have experienced a case of giant pulmonary artery aneurysm confirmed by computed tomography. A 38 year-old man with atrial septal defect admitted to Kanazawa City Hospital. He had been pointed out of a right hilar mass when he was 26 years old. His complaint was bloody sputum and cough. Pulmonary angiography was not useful for the definite diagnosis because of its mural thrombi. Enhanced computed tomography showed a giant pulmonary artery aneurysm with a mural thrombi in its cavity. This shows that enhanced computed tomography is very useful for the diagnosis of a pulmonary artery aneurysm with a mural thrombi in its cavity. (author)

  2. Computed tomographic diagnosis of pulmonary artery aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Maeno, Kouji; Kontani, Kazuhiro; Ito, Makoto; Sakurai, Noboru; Sawada, Taisei; Fukeda, Yasuhiko; Takata, Shigeo; Ikeda, Takayuki; Hattori, Nobu

    1986-05-01

    Pulmonary artery aneurysms are rare lesions. Clagett et al reported that one aneurysm of the pulmonary artery may be found in approximately 14,000 necropsies. We have experienced a case of giant pulmonary artery aneurysm confirmed by computed tomography. A 38 year-old man with atrial septal defect admitted to Kanazawa City Hospital. He had been pointed out of a right hilar mass when he was 26 years old. His complaint was bloody sputum and cough. Pulmonary angiography was not useful for the definite diagnosis because of its mural thrombi. Enhanced computed tomography showed a giant pulmonary artery aneurysm with a mural thrombi in its cavity. This shows that enhanced computed tomography is very useful for the diagnosis of a pulmonary artery aneurysm with a mural thrombi in its cavity.

  3. Advances in endovascular aneurysm treatment: are we making a difference?

    International Nuclear Information System (INIS)

    Katz, Jeffrey M.; Ougorets, Igor; Tsiouris, Apostolos J.; Biondi, Alessandra; Salvaggio, Kimberly A.; Gobin, Y. Pierre; Stieg, Philip E.; Riina, Howard A.

    2005-01-01

    Recent advancements in endovascular aneurysm repair, including bioactive and expansile coils and intracranial stents, hold promise for improved aneurysm occlusion rates. We report the immediate and midterm clinical and angiographic outcomes of a consecutive series of patients treated since the advent of these technologies. Clinical and radiological records of 134 patients with 142 aneurysms treated between 2001 and 2004 were retrospectively evaluated by an independent neurologist. Endovascular procedures were analyzed by an independent neuroradiologist blinded to all clinical information. Seventy-two ruptured and 60 un-ruptured saccular aneurysms, nine fusiform and one post-traumatic aneurysm were treated. Matrix coils were used in 53% of saccular aneurysms and HydroCoils in 13% of all aneurysms. Neuroform stents were deployed in 19% of aneurysms. Angiographic total or subtotal occlusion was achieved in 76% of cases and in 96% at last follow-up. Aneurysm recanalization was observed in 14% over a mean follow-up of 12 months, and 18% of aneurysms were retreated. Clinically relevant complications occurred in 6.0%, resulting in procedure-related morbidity of 0.6% and 0.6% mortality at 6 months. No aneurysm bled over a cumulative 1,347 months of observation. Newer embolization technologies can be exploited successfully even in more complex aneurysms with very low morbidity and mortality. (orig.)

  4. Intravenous DSA as a screening method for cerebral aneurysms

    International Nuclear Information System (INIS)

    Fukaya, Hiroyuki; Sunami, Kaneo; Hoshi, Seiichiro; Komiya, Hirokazu; Saeki, Naokatsu.

    1990-01-01

    Intravenous DSA (IVDSA) was evaluated as a screening method for cerebral aneurysms. It was performed 390 times in 372 cases. Clinically useful images were obtained in 94.1% in all examinations. Nineteen aneurysms were visualized in cerebral angiography among 21 cases with SAH or 3rd nerve palsy, whereas in IVDSA 15 aneurysms were noted. Aneurysms not visualized in IVDSA were all 4 mm or less in size. Therefore, aneurysms, more than 4 mm in size, which have higher risks for rupture, were detectable in IVDSA. Based on these findings, IVDSA is considered to be clinically useful in screening for aneurysms. In all 372 cases, 33 aneurysms were suspected in IVDSA findings, whereas in cerebral angiography 21 of them turned to be aneurysms. Such 12 false positive cases were distributed mainly at anterior communicating and middle cerebral arteries. Improvement of image resolution, avoidance of vessel overlapping and proper selection of screened cases should be investigated for further development of this screening method. (author)

  5. Aneurysm pulsatility after endovascular exclusion: an experimental study using human aortic aneurysms

    Directory of Open Access Journals (Sweden)

    Hussein Amin Orra

    2008-01-01

    Full Text Available OBJECTIVE: To measure the pulsatility of human aneurysms before and after complete exclusion with an endograft. METHOD: Five aortic aneurysms obtained during necropsy were submitted to pulsatile perfusion before and after implantation of a bifurcated endograft. The specimens were contained in a closed chamber filled with saline solution. A vertical tube attached to the chamber was used to measure volume dislocation in each systole. Mural thrombus was kept intact, and the space around the device was filled with human blood. After each experiment, the aneurysm was opened to check for the correct positioning and attachment of the device. RESULTS: The level of the saline column oscillated during pulsation in each case, with respective amplitudes of 17, 16, 13, 7, and 25 cm before the endograft insertion. After the insertion, the amplitudes dropped to 13, 12, 9, 3.5, and 23 cm, respectively. The differences were not significant. During the post-experimental examination, all devices were found to be in position and well attached to the neck and iliacs. No endoleak was detected during perfusion or by visual inspection. CONCLUSION: Pulsation of an endograft is transmitted to the aneurysm wall even in the absence of endoleak, and should not be interpreted as procedural failure.

  6. [Albert Einstein and his abdominal aortic aneurysm].

    Science.gov (United States)

    Cervantes Castro, Jorge

    2011-01-01

    The interesting case of Albert Einstein's abdominal aortic aneurysm is presented. He was operated on at age 69 and, finding that the large aneurysm could not be removed, the surgeon elected to wrap it with cellophane to prevent its growth. However, seven years later the aneurysm ruptured and caused the death of the famous scientist.

  7. Abciximab for thrombolysis during intracranial aneurysm coiling

    International Nuclear Information System (INIS)

    Gralla, Jan; Rennie, Adam T.M.; Corkill, Rufus A.; Lalloo, Shivendra T.; Molyneux, Andrew; Byrne, James V.; Kuker, Wilhem

    2008-01-01

    Thrombotic events are a common and severe complication of endovascular aneurysm treatment with significant impact on patients' outcome. This study evaluates risk factors for thrombus formation and assesses the efficacy and safety of abciximab for clot dissolution. All patients treated with abciximab during (41 patients) or shortly after (22 patients) intracranial aneurysm coil embolisation were retrieved from the institutional database (2000 to 2007, 1,250 patients). Sixty-three patients (mean age, 55.3 years, ±12.8) had received either intra-arterial or intravenous abciximab. Risk factors for clot formation were assessed and the angiographic and clinical outcome evaluated. No aneurysm rupture occurred during or after abciximab application. The intra-procedural rate of total recanalisation was 68.3%. Thromboembolic complications were frequently found in aneurysms of the Acom complex and of the basilar artery, whilst internal carotid artery aneurysms were underrepresented. Two patients died of treatment-related intracranial haemorrhages into preexisting cerebral infarcts. Two patients developed a symptomatic groin haematoma. Abciximab is efficacious and safe for thrombolysis during and after endovascular intracranial aneurysm treatment in the absence of preexisting ischaemic stroke. (orig.)

  8. Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?

    International Nuclear Information System (INIS)

    Baumueller, Stephan; Nguyen, Thi Dan Linh; Goetti, Robert Paul; Lachat, Mario; Seifert, Burkhardt; Pfammatter, Thomas; Frauenfelder, Thomas

    2011-01-01

    Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard. Materials and Methods: Forty-nine consecutive patients (73 ± 7.5 years, range 51–88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular to the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard. Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001). Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.

  9. Training model for cerebral aneurysm clipping

    Directory of Open Access Journals (Sweden)

    Hiroshi Tenjin, M.D., Ph.D.

    2017-12-01

    Full Text Available Clipping of cerebral aneurysms is still an important skill in neurosurgery. We have made a training model for the clipping of cerebral aneurysms. The concepts for the model were 1: training model for beginners, 2: three dimensional manipulation using an operating microscope, 3: the aneurysm model is to be perfused by simulated blood causing premature rupture. The correct relationship between each tissue, and softness of the brain and vessels were characteristics of the model. The skull, brain, arteries, and veins were made using a 3D printer with data from DICOM. The brain and vessels were made from polyvinyl alcohol (PVA. One training course was held and this model was useful for training of cerebral aneurysm surgery for young neurosurgeons.

  10. Models of experimental saccular aneurysms of carotid arteries in canine

    International Nuclear Information System (INIS)

    Zhang Haixia; Cheng Yingsheng; Li Minghua

    2006-01-01

    Objective: To study the availability by making experimental saccular aneurysm models of carotid arteries in canine similar to human intracranial aneurysms. Methods: Twenty healthy canines with experimental saccular side-wall aneurysms of carotid arteries were created successfully by surgery. Results: Forty experimental saccular side-wall aneurysms of carotid arteries were created successfully with 36 aneurysms and parent arteries maintaining patency with each other and four spontaneously occluded confirmed by angiography. Model successful rate reached 90%. Conclusions: Experimental saccular side-wall aneurysms of carotid arteries in canines were one of best models created for simulating human intracranial aneurysms. (authors)

  11. Impact of Right-Sided Aneurysm, Rupture Status, and Size of Aneurysm on Perforator Infarction Following Microsurgical Clipping of Posterior Communicating Artery Aneurysms with a Distal Transsylvian Approach.

    Science.gov (United States)

    Tanabe, Jun; Ishikawa, Tatsuya; Moroi, Junta; Sakata, Yoshinori; Hadeishi, Hiromu

    2018-03-01

    Posterior communicating artery (PCoA) aneurysms are among the most common aneurysms. Because blockage of the PCoA and perforators can cause adverse outcomes, occlusion of these arteries by surgical clipping should be avoided. The impact of factors on PCoA perforator infarction when using a distal transsylvian approach for PCoA aneurysms was examined. A total of 183 patients underwent PCoA aneurysm clipping, excluding application of fenestrated clips. Patients were divided into 2 groups: patients with PCoA perforator infarction (infarction group) and patients without infarction (noninfarction group). Multiple factors were analyzed in the 2 groups. Twenty-two of the 183 patients (12.0%) showed perforator infarction, mainly on magnetic resonance imaging evaluation, resulting in permanent deficits in 2 patients (1.1%). The proportion of right-sided operations (86.4% vs. 53.4%; P = 0.005) and surgery for rupture (90.9% vs. 55.9%; P = 0.002) were significantly higher in the infarction group than in the noninfarction group. Aneurysms were significantly larger in the infarction group (8.4 ± 3.8 mm) than in the noninfarction group (6.3 ± 3.0 mm; P = 0.02). Ruptured status (odds ratio [OR], 7.35; P = 0.01), right side (OR, 5.19; P = 0.01), and aneurysm size (OR, 1.18; P = 0.02) remained independent predictors of perforator infarction on multivariate logistic regression analysis. Ruptured status, right side, and large PCoA aneurysm were independent predictors of PCoA perforator infarction. Symptoms due to PCoA perforating infarction were mostly transient and rarely affected outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Endovascular Aneurysm Repair of Acute Occlusion of Abdominal Aortic Aneurysm with Intra-Aneurysmal Dissection.

    Science.gov (United States)

    Terai, Yasuhiko; Mitsuoka, Hiroshi; Nakai, Masanao; Goto, Shinnosuke; Miyano, Yuta; Tsuchiya, Hirokazu; Yamazaki, Fumio

    2015-11-01

    To report a rare case of acute abdominal aortic aneurysm (AAA) occlusion successfully treated by endovascular aneurysm repair (EVAR). An 89-year-old man complained of severe back pain and weakness in the bilateral lower extremities. Although there were neither acute ischemic signs on the brain computed tomography (CT) nor critical leg ischemia, the patient presented progressing weakness in the bilateral lower extremities and decreased sensation in the perianal and saddle area. Contrast-enhanced CT demonstrated an infrarenal AAA, the formation of an ulcer-like lesion in the aneurysmal wall, and the complete occlusion of distal AAA because of the caudal extension of intramural hematoma. Both common iliac arteries were patent because of the development of collateral vessels. The neurologic symptoms were considered to be caused by the occlusion of lumbar radicular arteries. EVAR seemed anatomically feasible, if the occlusion could be crossed by guidewires from both side of the common femoral artery. Wires easily traversed the occlusion, and the stent graft could be smoothly unwrapped and opened. The patient could recover decent iliac arterial flow. The neurovascular deficits recovered within 4 days after the procedure. Although our experience may not be reproduced in all case of AAA occlusion, EVAR warrants consideration to reduce the high mortality rate associated with the classical treatments. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Management of aneurysmal subarachnoid hemorrhage.

    Science.gov (United States)

    Etminan, N; Macdonald, R L

    2017-01-01

    Spontaneous subarachnoid hemorrhage (SAH) affects people with a mean age of 55 years. Although there are about 9/100 000 cases per year worldwide, the young age and high morbidity and mortality lead to loss of many years of productive life. Intracranial aneurysms account for 85% of cases. Despite this, the majority of survivors of aneurysmal SAH have cognitive deficits, mood disorders, fatigue, inability to return to work, and executive dysfunction and are often unable to return to their premorbid level of functioning. The main proven interventions to improve outcome are aneurysm repair in a timely fashion by endovascular coiling rather than neurosurgical clipping when feasible and administration of nimodipine. Management also probably is optimized by neurologic intensive care units and multidisciplinary teams. Improved diagnosis, early aneurysm repair, administration of nimodipine, and advanced neurointensive care support may be responsible for improvement in survival from SAH in the last few decades. © 2017 Elsevier B.V. All rights reserved.

  14. Surgical management of giant posterior communicating artery aneurysms.

    Science.gov (United States)

    Velat, Gregory J; Zabramski, Joseph M; Nakaji, Peter; Spetzler, Robert F

    2012-09-01

    Giant posterior communicating artery (PCoA) aneurysms (> 25 mm) are rare lesions associated with a poor prognosis and high rates of morbidity and mortality. To review the clinical results of giant PCoA aneurysms surgically treated at our institution, focusing on operative nuances. All cases of giant PCoA aneurysms treated surgically at our institution were identified from a prospectively maintained patient database. Patient demographic factors, medical comorbidities, rupture status, neurological presentation, clinical outcomes, and surgical records were critically reviewed. From 1989 to 2010, 11 patients (10 women) underwent surgical clipping of giant PCoA aneurysms. Presenting signs and symptoms included cranial nerve palsies, diminished mental status, headache, visual changes, and seizures. Five aneurysms were ruptured on admission. All aneurysms were clipped primarily except 1, which was treated by parent artery sacrifice and extracranial-to-intracranial bypass after intraoperative aneurysm rupture. Perioperative morbidity and mortality rates were 36% (4 of 11) and 18.3% (2 of 11), respectively. Excellent or good clinical outcomes, defined as modified Rankin Scale scores ≤ 2, were achieved in 86% (5 of 6) of patients available for long-term clinical follow-up (mean, 12.5 ± 13.6 months). Giant PCoA aneurysms are rare vascular lesions that may present with a variety of neurological signs and symptoms. These lesions can be successfully managed surgically with satisfactory morbidity and mortality rates. To the best of our knowledge, this is the largest surgical series of giant PCoA aneurysms published to date.

  15. Individualized management for intracranial vertebral artery dissecting aneurysms

    Directory of Open Access Journals (Sweden)

    SHANG Yan-guo

    2012-02-01

    Full Text Available Objective To discuss the individualized management strategy for intracranial vertebral artery dissecting aneurysms. Methods Eighteen patients with intracranial vertebral artery dissecting aneurysms were treated with different surgical methods. Results Eighteen patients underwent different surgical treatment. Five patients underwent complete occlusion of the aneurysm and parent artery by coiling, 5 were treated by stent -assisted coiling (3 densely packed coiling and 2 non-densely packed coiling, 4 underwent stent-only therapy and 3 of them presented hemodynamic improvement after surgery, 3 were treated by direct surgical clipping, and 1 underwent occipital artery-posterior inferior cerebellar artery bypass. Two aneurysms ruptured immaturely, in which one patient died on the third day after operation and one patient occurred moderate disablity. Only 1 patient who underwent complete occlusion of aneurysm and parent artery presented temporarily ischemic symptoms. No adverse effects were seen in other patients. Seventeen patients were followed up for 1 month to 3 years, and all the aneurysms were stable. Conclusion There are many kinds of therapeutic methods for intracranial vertebral artery dissecting aneurysms. The patients should be treated according to several factors such as the clinical manifestations, aneurysm configuration, and relationship with the posterior inferior cerebellar artery. The treatment should be individualized.

  16. Value of three-dimensional computed tomography in screening cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Tamaki; Sugiura, Yusuke; Suzuki, Atsushi; Yamagata, Yoshitaka [Hyogo Medical Coll. (Japan)

    1997-10-01

    We performed three-dimensional computed tomography (3D-CT) in 6 patients of cerebral aneurysm. Prior cerebral angiography showed a total of 17 aneurysms. 3D-CT alone detected 10 cerebral aneurysm (59%). It was possible to identify aneurysms larger than 10 mm even when located near the circle of Willis. It was difficult to identify aneurysms when smaller than 7 mm regardless of their location. 3D-CT was of limited value in detecting cerebral aneurysms, particularly when located near the circle of Willis with complex vascular network. As cases of oculomotor palsy may be caused by lesions other than cerebral aneurysm, we advocate that 3D-CT be performed after magnetic resonance imaging (MRI) in screening cases of suspected cerebral aneurysm. (author)

  17. Shape-memory polymer foam device for treating aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, Jason M.; Benett, William J.; Small, Ward; Wilson, Thomas S.; Maitland, Duncan J; Hartman, Jonathan

    2017-05-30

    A system for treating an aneurysm in a blood vessel or vein, wherein the aneurysm has a dome, an interior, and a neck. The system includes a shape memory polymer foam in the interior of the aneurysm between the dome and the neck. The shape memory polymer foam has pores that include a first multiplicity of pores having a first pore size and a second multiplicity of pores having a second pore size. The second pore size is larger than said first pore size. The first multiplicity of pores are located in the neck of the aneurysm. The second multiplicity of pores are located in the dome of the aneurysm.

  18. Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography

    International Nuclear Information System (INIS)

    Young, N.; Kingston, R.J.; Markson, G.; Dorsch, N.W.C.; McMahon, J.

    2001-01-01

    The goal of this study was to assess the usefulness of spiral CT angiography (CTA) with three- dimensional reconstructions in defining intracranial aneurysms, particularly around the Circle of Willis. Two hundred consecutive patients with angiographic and/or surgical correlation were studied between 1993 and 1998, with CTA performed on a GE HiSpeed unit and Windows workstation. The following clinical situations were evaluated: conventional CT suspicion of an aneurysm; follow-up of treated aneurysm remnants or of untreated aneurysms; subarachnoid haemorrhage (SAH) and negative angiography; family or past aneurysm history; and for improved definition of aneurysm anatomy. Spiral CTA detected 140 of 144 aneurysms, and an overall sensitivity of 97%, including 30 of 32 aneurysms 3 mm or less in size. In 38 patients with SAH and negative angiography, CTA found six of the seven aneurysms finally diagnosed. There was no significant artefact in 17 of 23 patients (74%) with clips. The specificity of CTA was 86% with 8 false-positive cases. Spiral CTA is very useful in demonstrating intracranial aneurysms. (orig.)

  19. Aortic Disease in the Young: Genetic Aneurysm Syndromes, Connective Tissue Disorders, and Familial Aortic Aneurysms and Dissections

    Directory of Open Access Journals (Sweden)

    Marcelo Cury

    2013-01-01

    Full Text Available There are many genetic syndromes associated with the aortic aneurysmal disease which include Marfan syndrome (MFS, Ehlers-Danlos syndrome (EDS, Loeys-Dietz syndrome (LDS, familial thoracic aortic aneurysms and dissections (TAAD, bicuspid aortic valve disease (BAV, and autosomal dominant polycystic kidney disease (ADPKD. In the absence of familial history and other clinical findings, the proportion of thoracic and abdominal aortic aneurysms and dissections resulting from a genetic predisposition is still unknown. In this study, we propose the review of the current genetic knowledge in the aortic disease, observing, in the results that the causative genes and molecular pathways involved in the pathophysiology of aortic aneurysm disease remain undiscovered and continue to be an area of intensive research.

  20. Cerebral aneurysms – an audit

    African Journals Online (AJOL)

    Enrique

    Abstract. We performed an audit to determine the profile of cerebral aneurysms at the Universitas Hospital Bloem- fontein, the only government hospital with a vascular suite in the Free State and Northern Cape area. Two hun- dred and twenty-three government patients, diagnosed with cerebral aneurysms during the period.

  1. Magnetic resonance imaging of large and giant intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Kenichi; Saito, Akira; Nakasu, Yoko; Matsuda, Masayuki; Handa, Jyoji [Shiga University of Medical Science, Shiga (Japan); Todo, Giro

    1990-06-01

    Twelve large or giant intracranial aneurysms were studied with magnetic resonance (MR) imaging, and the findings were compared with those from computed tomographic (CT) scanning. Characteristic MR features of such aneurysms are: round, extra-axial mass with hypointensity rim; signal void, paradoxical enhancement, or even-echo rephasing due to blood flow; and laminated, eccentric thrombus with increased signal intensity when fresh, perianeurysmal hemorrhage occurs in the acute or subacute stage after aneurysmal rupture. MR imaging, however, often fails to identify or characterize the area of calcification. For the diagnosis of large or giant intracranial aneurysms, MR imaging is apparently superior to CT scanning in differentiating aneurysms from tumors, delineating the blood flow and intraluminal thrombus, and detecting the exact size of the aneurysm. It may also provide useful information concerning the growth mechanisms of aneurysms with or without thrombus formation. (author).

  2. Giant aneurysm in 6 years old child - case report

    International Nuclear Information System (INIS)

    Sirakov, S.; Penkov, M.; Todorov, Y; Minkin, K.

    2014-01-01

    Intracranial saccular aneurysms rare in childhood is. Even among the reported series of childhood aneurysms, it is unusual to find their occurrence in children less than 7 years old. The pathogenesis of these lesions is also a matter of debate and speculations. The peak age of incidence of juvenile cerebral aneurysms appear to be 12 years, occurrence below the age of 7 being rarity. We show a case of 6 years old boy with giant aneurysm. found because of episodes of headache and vomiting. Discussion of pathogenesis for the rare pathology. After discussion of multidisciplinary team, of neuroradiologist and neurosurgeons was decided to be perform endovascular embolization, because of the better outcome for the patient. We performed endovascular treatment of the aneurysm with achieving total embolization. The patient recovery completely, and after 4 days went home. (authors) Key words: GIANT ANEURYSM. SACCULAR ANEURYSM. EMBOLIZATION. STENT ASSISTED COILING

  3. Hemodynamic response during aneurysm clipping surgery among experienced neurosurgeons.

    Science.gov (United States)

    Bunevicius, Adomas; Bilskiene, Diana; Macas, Andrius; Tamasauskas, Arimantas

    2016-02-01

    Neurosurgery is a challenging field associated with high levels of mental stress. The goal of this study was to investigate the hemodynamic response of experienced neurosurgeons during aneurysm clipping surgery and to evaluate whether neurosurgeons' hemodynamic responses are associated with patients' clinical statuses. Four vascular neurosurgeons (all male; mean age 51 ± 10 years; post-residency experience ≥7 years) were studied during 42 aneurysm clipping procedures. Blood pressure (BP) and heart rate (HR) were assessed at rest and during seven phases of surgery: before the skin incision, after craniotomy, after dural opening, after aneurysm neck dissection, after aneurysm clipping, after dural closure and after skin closure. HR and BP were significantly greater during surgery relative to the rest situation (p ≤ 0.03). There was a statistically significant increase in neurosurgeons' HR (F [6, 41] = 10.88, p neurosurgeon experience, the difference in BP as a function of aneurysm rupture was not significant (p > 0.08). Aneurysm location, intraoperative aneurysm rupture, admission WFNS score, admission Glasgow Coma Scale scores and Fisher grade were not associated with neurosurgeons' intraoperative HR and BP (all p > 0.07). Aneurysm clipping surgery is associated with significant hemodynamic system activation among experienced neurosurgeons. The greatest HR and BP were after aneurysm neck dissection and clipping. Aneurysm location and patient clinical status were not associated with intraoperative changes of neurosurgeons' HR and BP.

  4. Is tube repair of aortic aneurysm followed by aneurysmal change in the common iliac arteries?

    Science.gov (United States)

    Provan, J L; Fialkov, J; Ameli, F M; St Louis, E L

    1990-10-01

    To address the concern that tube repair of an abdominal aortic aneurysm might be followed by aneurysmal change in the common iliac arteries, 23 patients who had undergone the operation were re-examined 3 to 5 years later. Although 9 had had minimal ectasia of these arteries preoperatively, in none of the 23 was there symptomatic or radiologic evidence of aneurysmal change on follow-up. Measurements of the maximum intraluminal diameters were made by computed tomography; they indicated no significant differences between the preoperative and follow-up sizes of the common iliac arteries. The variation in time to follow-up also showed no significant correlation with change in artery diameter.

  5. Endovascular treatment of renal aneurysms: A series of 18 cases

    International Nuclear Information System (INIS)

    Sédat, J.; Chau, Y.; Baque, J.

    2012-01-01

    Purpose: To retrospectively analyze the results and complications of the endovascular treatment of 18 renal aneurysms. Methods: From 2002 to 2011, 15 patients (aged 31–76), with 18 renal aneurysms, were admitted in our institution for treatment by embolization. Except one, all were wide-necked aneurysms. One aneurysm was treated by occluding the parent artery considering its distal location; a small-necked aneurysm was treated by simple coiling, and the remaining 16 were embolized utilizing adjunctive techniques to protect the parent artery. We analyzed the rates of technical success, complication and clinical consequence, post-operative occlusion and recurrence. Results: There was a 100% technical success rate. 15 aneurysms showed a total occlusion on the post-treatment angiogram. 2 aneurysms demonstrated neck remnants, and one had an intrasaccular residual in-flow. Two minor post-operative complications were encountered but resolved over time. No delayed clinical complications were observed and the long-term angiographic follow-up demonstrated stability of the occlusion of the target renal aneurysm with no major recurrence. Conclusion: Complications of the embolization of renal aneurysms are rare. Endovascular treatment should therefore be considered at first for the treatment of renal aneurysms.

  6. Morphology parameters for intracranial aneurysm rupture risk assessment.

    Science.gov (United States)

    Dhar, Sujan; Tremmel, Markus; Mocco, J; Kim, Minsuok; Yamamoto, Junichi; Siddiqui, Adnan H; Hopkins, L Nelson; Meng, Hui

    2008-08-01

    The aim of this study is to identify image-based morphological parameters that correlate with human intracranial aneurysm (IA) rupture. For 45 patients with terminal or sidewall saccular IAs (25 unruptured, 20 ruptured), three-dimensional geometries were evaluated for a range of morphological parameters. In addition to five previously studied parameters (aspect ratio, aneurysm size, ellipticity index, nonsphericity index, and undulation index), we defined three novel parameters incorporating the parent vessel geometry (vessel angle, aneurysm [inclination] angle, and [aneurysm-to-vessel] size ratio) and explored their correlation with aneurysm rupture. Parameters were analyzed with a two-tailed independent Student's t test for significance; significant parameters (P 41; 95% confidence interval, 1.03-1.92) and undulation index (odds ratio, 1.51; 95% confidence interval, 1.08-2.11) had the strongest independent correlation with ruptured IA. From the receiver operating characteristic analysis, size ratio and aneurysm angle had the highest area under the curve values of 0.83 and 0.85, respectively. Size ratio and aneurysm angle are promising new morphological metrics for IA rupture risk assessment. Because these parameters account for vessel geometry, they may bridge the gap between morphological studies and more qualitative location-based studies.

  7. Infectious or Noninfectious? Ruptured, Thrombosed Inflammatory Aortic Aneurysm with Spondylolysis

    Energy Technology Data Exchange (ETDEWEB)

    Stefanczyk, Ludomir; Elgalal, Marcin, E-mail: telgalal@yahoo.co.uk [Medical University of Lodz, Department of Radiology and Diagnostic Imaging (Poland); Papiewski, Andrzej [Medical University of Lodz, Department of Gastroenterological Surgery (Poland); Szubert, Wojciech [Medical University of Lodz, Department of Radiology and Diagnostic Imaging (Poland); Szopinski, Piotr [Institute of Hematology and Transfusion Medicine, Clinic of Vascular Surgery (Poland)

    2013-06-15

    Osteolysis of vertebrae due to inflammatory aortic aneurysm is rarely observed. However, it is estimated that up to 10 % of infectious aneurysms coexist with bone tissue destruction, most commonly the vertebrae. Inflammatory aneurysms with no identified infection factor, along with infiltration of adjacent muscle and in particular extensive destruction of bone tissue have rarely been described in the literature. A case of inflammatory aneurysm with posterior wall rupture and inflammatory infiltration of the iliopsoas muscle and spine, together with extensive vertebral body destruction, is presented. The aneurysm was successfully treated with endovascular aneurysm repair EVAR.

  8. Infectious or Noninfectious? Ruptured, Thrombosed Inflammatory Aortic Aneurysm with Spondylolysis

    International Nuclear Information System (INIS)

    Stefańczyk, Ludomir; Elgalal, Marcin; Papiewski, Andrzej; Szubert, Wojciech; Szopiński, Piotr

    2013-01-01

    Osteolysis of vertebrae due to inflammatory aortic aneurysm is rarely observed. However, it is estimated that up to 10 % of infectious aneurysms coexist with bone tissue destruction, most commonly the vertebrae. Inflammatory aneurysms with no identified infection factor, along with infiltration of adjacent muscle and in particular extensive destruction of bone tissue have rarely been described in the literature. A case of inflammatory aneurysm with posterior wall rupture and inflammatory infiltration of the iliopsoas muscle and spine, together with extensive vertebral body destruction, is presented. The aneurysm was successfully treated with endovascular aneurysm repair EVAR.

  9. Comprehensive Overview of Contemporary Management Strategies for Cerebral Aneurysms.

    Science.gov (United States)

    Manhas, Amitoz; Nimjee, Shahid M; Agrawal, Abhishek; Zhang, Jonathan; Diaz, Orlando; Zomorodi, Ali R; Smith, Tony; Powers, Ciarán J; Sauvageau, Eric; Klucznik, Richard P; Ferrell, Andrew; Golshani, Kiarash; Stieg, Philip E; Britz, Gavin W

    2015-10-01

    Aneurysmal subarachnoid hemorrhage (SAH) remains an important health issue in the United States. Despite recent improvements in the diagnosis and treatment of cerebral aneurysms, the mortality rate following aneurysm rupture. In those patients who survive, up to 50% are left severely disabled. The goal of preventing the hemorrhage or re-hemorrhage can only be achieved by successfully excluding the aneurysm from the circulation. This article is a comprehensive review by contemporary vascular neurosurgeons and interventional neuroradiolgists on the modern management of cerebral aneurysms. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Koike, Yuya, E-mail: r06118@hotmail.co.jp; Nishimura, Jun-ichi, E-mail: jun-ichi-n@nifty.com; Hase, Soichiro, E-mail: haseman@hotmail.co.jp; Yamasaki, Motoshige, E-mail: genyamasaki@gmail.com [Kawasaki Saiwai Hospital, Department of Interventional Radiology (Japan)

    2015-04-15

    PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasation of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.

  11. Treatment strategy for ruptured abdominal aortic aneurysms.

    Science.gov (United States)

    Davidovic, L

    2014-07-01

    Rupture is the most serious and lethal complication of the abdominal aortic aneurysm. Despite all improvements during the past 50 years, ruptured abdominal aortic aneurysms are still associated with very high mortality. Namely, including patients who die before reaching the hospital, the mortality rate due to abdominal aortic aneurysm rupture is 90%. On the other hand, during the last twenty years, the number of abdominal aortic aneurysms significantly increased. One of the reasons is the fact that in majority of countries the general population is older nowadays. Due to this, the number of degenerative AAA is increasing. This is also the case for patients with abdominal aortic aneurysm rupture. Age must not be the reason of a treatment refusal. Optimal therapeutic option ought to be found. The following article is based on literature analysis including current guidelines but also on my Clinics significant experience. Furthermore, this article show cases options for vascular medicine in undeveloped countries that can not apply endovascular procedures at a sufficient level and to a sufficient extent. At this moment the following is evident. Thirty-day-mortality after repair of ruptured abdominal aortic aneurysms is significantly lower in high-volume hospitals. Due to different reasons all ruptured abdominal aortic aneurysms are not suitable for EVAR. Open repair of ruptured abdominal aortic aneurysm should be performed by experienced open vascular surgeons. This could also be said for the treatment of endovascular complications that require open surgical conversion. There is no ideal procedure for the treatment of AAA. Each has its own advantages and disadvantages, its own limits and complications, as well as indications and contraindications. Future reductions in mortality of ruptured abdominal aortic aneurysms will depend on implementation of population-based screening; on strategies to prevent postoperative organ injury and also on new medical technology

  12. A fluid-structure interaction study using patient-specific ruptured and unruptured aneurysm: the effect of aneurysm morphology, hypertension and elasticity.

    Science.gov (United States)

    Lee, C J; Zhang, Y; Takao, H; Murayama, Y; Qian, Y

    2013-09-27

    Fluid-structure interaction (FSI) simulations using five patient-specific aneurysm geometries are carried out to investigate the difference between ruptured and unruptured aneurysms. Two different blood pressure conditions (normal and hypertension, for all cases), and two different values of elastic modulus (1 and 2MPa, for two cases) are tested. Ruptured aneurysms (RA) generally displayed larger displacement at the dome, lower area-average WSS and higher von Mises stress than unruptured aneurysms (URA) regardless of elasticity or blood pressure condition. RAs had a longitudinal expansion whereas URAs had a radial expansion, which was the key difference between the two types. The difference in expansion pattern may be one of the keys to explaining aneurysm rupture, and further analysis is required in the future to confirm this theory. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. [Transesophageal echocardiography diagnosis of ruptured aneurysm of the Valsalva sinus associated with aneurysm of the interatrial septum].

    Science.gov (United States)

    Imperadore, Ferdinando; Ferro, Aldo; Graffigna, Angelo; Vergara, Giuseppe

    2002-01-01

    Aneurysms of the sinus of Valsalva are uncommon heart defects that often remain undetected unless rupture occurs. They have been reported in association with other cardiac anomalies. The present case report deals with a 51-year-old man who was referred to our division with a diagnosis of recent-onset progressive heart failure. Echocardiographic evaluation, both transthoracic and transesophageal, disclosed rupture of an aneurysm of the non-coronary sinus of Valsalva into the right atrium. This anomaly was associated with an aneurysm of the atrial septum.

  14. CT findings of subarachnoid hemorrhage due to ruptured cerebral aneurysm

    International Nuclear Information System (INIS)

    Kim, Pyo Nyun; Bae, Won Kyung; Kim, Il Young; Lee, Kyung Soo; Lee, Byoung Ho; Kim, Ki Jung

    1990-01-01

    CT scans were analysed retrospectively in 130 patients with subarachnoid hemorrhage (SAH) due to ruptured cerebral aneurysm to evaluate the relationship of the locations of aneurysms and the patterns of hemorrhage. Hemorrhage corresponded to the site of aneurysmal origin in a general way and in more specific ways to anterior communicating and middle cerebral artery aneurysms when there was parenchymal or cisternal hemorrhage. In anterior communicating artery aneurysm, SAH in the interhemispheric fissure, both sylvian fissures, and basal cistern was usually noted and intracerebral hemorrhage in anteroinferior frontal lobe was sometimes associated. In cases of middle cerebral artery aneurysm, hemorrhage in the ipsilateral sylvian fissure, interhemispheric fissure, and ipsilateral basal cistern was usual. Intracerebral hemorrhage in lateral temporal lobe was sometimes associated. Posterior communicating artery aneurysm demonstrated SAH in the ipsilateral basal cistern or in entire cisternal spaces specifically, so with higher incidence of involvement of the quadrigeminal and superior cerebellar cistern than anterior cerebral or middle cerebral artery aneurysm. We suggest the locations of aneurysm might be predicted with patterns of SAH and / or associated intracerebral hemorrhage with CT

  15. Endoport-Assisted Microsurgical Treatment of a Ruptured Periventricular Aneurysm

    Directory of Open Access Journals (Sweden)

    Ching-Jen Chen

    2016-01-01

    Full Text Available Background and Importance. Ruptured periventricular aneurysms in patients with moyamoya disease represent challenging pathologies. The most common methods of treatment include endovascular embolization and microsurgical clipping. However, rare cases arise in which the location and anatomy of the aneurysm make these treatment modalities particularly challenging. Clinical Presentation. We report a case of a 34-year-old female with moyamoya disease who presented with intraventricular hemorrhage. CT angiography and digital subtraction angiography revealed an aneurysm located in the wall of the atrium of the right lateral ventricle. Distal endovascular access was not possible, and embolization risked the sacrifice of arteries supplying critical brain parenchyma. Using the BrainPath endoport system, the aneurysm was able to be accessed. Since the fusiform architecture of the aneurysm prevented clip placement, the aneurysm was ligated with electrocautery. Conclusion. We demonstrate the feasibility of endoport-assisted approach for minimally invasive access and treatment of uncommon, distally located aneurysms.

  16. Traumatic intracranial aneurysm: a case report

    International Nuclear Information System (INIS)

    Kang, Si Won; Chun, Kyung Ah; Baik, Joon Hyun; Shin, Kyung Sub

    1994-01-01

    The occurrence of traumatic aneurysm is rare in head injury, but this complication is important as it is a potentially treatable cause delayed onset of intracranial hemorrhage. Authors report one case of traumatic aneurysm involving A1 and A2 junction of anterior cerebral artery. A-28-year-old man with traffic accident was examined with brain CT and cerebral angiography. 1) Brain CT: Initial scan shows multiple skull fractures involving right frontal bones with subarachnoid hemorrhage and pneumocephalus. Follow-up scan shows intracerebral hemorrhage at bilateral frontal lobes. 2) Cerebral angiography: A traumatic aneurysm which is slowly filling and delayed emptying is noted at the junctional portion of A1 and A2 segment of the anterior cerebral artery. This report demonstrates radiologic findings of traumatic aneurysm at anterior cerebral artery with the brief review of the literatures

  17. Construct canine intracranial aneurysm model by endovascular technique

    International Nuclear Information System (INIS)

    Liang Xiaodong; Liu Yizhi; Ni Caifang; Ding Yi

    2004-01-01

    Objective: To construct canine bifurcation aneurysms suitable for evaluating the exploration of endovascular devices for interventional therapy by endovascular technique. Methods: The right common carotid artery of six dogs was expanded with a pliable balloon by means of endovascular technique, then embolization with detached balloon was taken at their originations DAS examination were performed on 1, 2, 3 d after the procedurse. Results: 6 aneurysm models were created in six dogs successfully with the mean width and height of the aneurysms decreasing in 3 days. Conclusions: This canine aneurysm model presents the virtue in the size and shape of human cerebral bifurcation saccular aneurysms on DSA image, suitable for developing the exploration of endovascular devices for aneurismal therapy. The procedure is quick, reliable and reproducible. (authors)

  18. Nuclear medical diagnostic with ventricular aneurysm

    International Nuclear Information System (INIS)

    Litter, H.

    1987-01-01

    In the diagnostic of ventricular aneurysms myocardial scintigraphy and above all radionuclide ventriculography (RNV) have special importance. Because of the non-invasive method and the as a result safe and easy use even with stress studies, RNV can provide a very valuable aid with aneurysm patients in early diagnosis, evaluation of the operability and as well as in the prognosis. It must be noted, however, that the differentiation of multivascular diseases and sometimes ventricular aneurysms can be difficult and the inclusion of an angiocardiograph as a radiological invasive examination procedure seems fitting. (orig./MG) [de

  19. Current management of inguinal false aneurysms

    DEFF Research Database (Denmark)

    Houlind, Kim; Jepsen, Jørn M; Saicu, Cristian

    2017-01-01

    False aneurysms are formed as a result of bleeding causing a hematoma to compress the surrounding tissue. The majority of false aneurysms presenting to the vascular surgeon are caused by iatrogenic injury to an artery. Although anastomotic failure occurs, a much higher number is caused by bleeding...... vessels. endovascular treatment with coils or covered stent grafts have proven useful in infected ilio-femoral false aneurysms. Open surgical repair may be the best treatment in the setting of imminent rupture, massive haematoma and skin necrosis. We present three patient cases treated with open surgery...

  20. Radiological analysis of subarachnoid hemorrhage from ruptured intracranial aneurysms

    International Nuclear Information System (INIS)

    Lee, Jong Doo; Suh, Jung Ho; Kim, Dong Ik

    1988-01-01

    The CT findings of 98 patients with subarachnoid hemorrhage due to aneurysmal rupture were analyzed and compared with cerebral angiography for the purpose of preangiographic prediction of aneurysmal location as well as evaluation of the CT features corresponding to the vasospasm or ischemic neurologic dysfunctions. The results were as follows: 1.Aneurysms could be identified on initial cerebral angiography in 82 out of 98 patients with subarachnoid hemorrhage and anterior communicating artery aneurysms were most common (42 cases), followed by MCA, posterior communicating artery, ICA, basilar artery in order of frequency. 2.The CT findings of those patients were hemorrhage in subarachnoid space (69%), localized hematoma (47%), ventricular dilatation (31%), enhancing nodule (23%), cisternal enhancement (20%), cerebral infarction (15%), ventricular hemorrhage (14%), and epidural hemorrhage (3%). 3.Localized hematoma was more prevalent in anterior communicating artery aneurysm rupture (54%), and less frequently in MCA, posterior communicating artery and ICA aneurysms. 4.Most of aneurysmal sac could be identified as enhancing nodule on CT when the real size were over 1 cm. 5.The size of ruptured aneurysm could be predicted in many patients with ACA and MCA aneurysm according to the CT features such as hemorrhagic patterns, location of hematomas or enhancing nodules. 6.Localized hematoma or blood clots and cerebral infarction are considered to be the CT features corresponding to the angiographic vasospasm

  1. Aneurysms with persistent filling after failed treatment with the Pipeline embolization device.

    Science.gov (United States)

    Daou, Badih; Atallah, Elias; Chalouhi, Nohra; Starke, Robert M; Oliver, Jeffrey; Montano, Maria; Jabbour, Pascal; Rosenwasser, Robert H; Tjoumakaris, Stavropoula I

    2018-05-04

    OBJECTIVE The Pipeline embolization device (PED) has become a valuable tool in the treatment of cerebral aneurysms. Although failures with PED treatment have been reported, the characteristics and course of these aneurysms remain a topic of uncertainty. METHODS Electronic medical records and imaging studies were reviewed for all patients treated with the PED between July 2010 and March 2015 to identify characteristics of patients and aneurysms with residual filling after PED treatment. RESULTS Of 316 cases treated at a single institution, 281 patients had a long-term follow-up. A total of 52 (16.4%) aneurysms with residual filling were identified and constituted the study population. The mean patient age in this population was 58.8 years. The mean aneurysm size was 10.1 mm ± 7.15 mm. Twelve aneurysms were fusiform (23%). Of the aneurysms with residual filling, there were 20 carotid ophthalmic (CO) aneurysms (20% of all CO aneurysms treated), 10 other paraclinoid aneurysms (16.4% of all paraclinoid aneurysms), 7 posterior communicating artery (PCoA) aneurysms (21.9% of all PCoA aneurysms), 7 cavernous internal carotid artery (ICA) aneurysms (14.9% of all cavernous ICA aneurysms), 4 vertebrobasilar (VB) junction aneurysms (14.8% of all VB junction aneurysms), and 3 middle cerebral artery (MCA) aneurysms (25% of all MCA aneurysms). Eleven patients underwent placement of more than one PED (21.2%), with a mean number of devices of 1.28 per case. Eight of 12 aneurysms were previously treated with a stent (15.4%). Nineteen patients underwent re-treatment (36.5%); the 33 patients who did not undergo re-treatment (63.5%) were monitored by angiography or noninvasive imaging. In multivariate analysis, age older than 65 years (OR 2.65, 95% CI 1.33-5.28; p = 0.05), prior stent placement across the target aneurysm (OR 2.94, 95% CI 1.15-7.51; p = 0.02), aneurysm location in the distal anterior circulation (MCA, PCoA, and anterior choroidal artery: OR 2.72, 95% CI 1.19-6.18; p

  2. Shared Genetic Risk Factors of Intracranial, Abdominal, and Thoracic Aneurysms

    NARCIS (Netherlands)

    van 't Hof, Femke N G; Ruigrok, Ynte M; Lee, Cue Hyunkyu; Ripke, Stephan; Anderson, Graig; de Andrade, Mariza; Baas, Annette F; Blankensteijn, Jan D; Böttinger, Erwin P; Bown, Matthew J; Broderick, Joseph; Bijlenga, Philippe; Carrell, David S; Crawford, Dana C; Crosslin, David R; Ebeling, Christian; Eriksson, Johan G; Fornage, Myriam; Foroud, Tatiana; von Und Zu Fraunberg, Mikael; Friedrich, Christoph M; Gaál, Emília I; Gottesman, Omri; Guo, Dong-Chuan; Harrison, Seamus C; Hernesniemi, Juha; Hofman, Albert; Inoue, Ituro; Jääskeläinen, Juha E; Jones, Gregory T; Kiemeney, Lambertus A L M; Kivisaari, Riku; Ko, Nerissa; Koskinen, Seppo; Kubo, Michiaki; Kullo, Iftikhar J; Kuivaniemi, Helena; Kurki, Mitja I; Laakso, Aki; Lai, Dongbing; Leal, Suzanne M; Lehto, Hanna; LeMaire, Scott A; Low, Siew-Kee; Malinowski, Jennifer; McCarty, Catherine A; Milewicz, Dianna M; Mosley, Thomas H; Nakamura, Yusuke; Nakaoka, Hirofumi; Niemelä, Mika; Pacheco, Jennifer; Peissig, Peggy L; Pera, Joanna; Rasmussen-Torvik, Laura; Ritchie, Marylyn D; Rivadeneira, Fernando; van Rij, Andre M; Santos-Cortez, Regie Lyn P; Saratzis, Athanasios; Slowik, Agnieszka; Takahashi, Atsushi; Tromp, Gerard; Uitterlinden, André G; Verma, Shefali S; Vermeulen, Sita H; Wang, Gao T; Han, Buhm; Rinkel, Gabriël J E; de Bakker, Paul I W

    2016-01-01

    BACKGROUND: Intracranial aneurysms (IAs), abdominal aortic aneurysms (AAAs), and thoracic aortic aneurysms (TAAs) all have a familial predisposition. Given that aneurysm types are known to co-occur, we hypothesized that there may be shared genetic risk factors for IAs, AAAs, and TAAs. METHODS AND

  3. Shared genetic risk factors of intracranial, abdominal, and thoracic aneurysms

    NARCIS (Netherlands)

    van 't Hof, Femke N G; Ruigrok, Ynte M; Lee, Cue Hyunkyu; Ripke, Stephan; Anderson, Graig; de Andrade, Mariza; Baas, Annette F; Blankensteijn, Jan D; Böttinger, Erwin P; Bown, Matthew J; Broderick, Joseph; Bijlenga, Philippe; Carrell, David S; Crawford, Dana C; Crosslin, David R; Ebeling, Christian; Eriksson, Johan G; Fornage, Myriam; Foroud, Tatiana; von Und Zu Fraunberg, Mikael; Friedrich, Christoph M; Gaál, Emília I; Gottesman, Omri; Guo, Dong-Chuan; Harrison, Seamus C; Hernesniemi, Juha; Hofman, Albert; Inoue, Ituro; Jääskeläinen, Juha E; Jones, Gregory T; Kiemeney, Lambertus A L M; Kivisaari, Riku; Ko, Nerissa; Koskinen, Seppo; Kubo, Michiaki; Kullo, Iftikhar J; Kuivaniemi, Helena; Kurki, Mitja I; Laakso, Aki; Lai, Dongbing; Leal, Suzanne M; Lehto, Hanna; LeMaire, Scott A; Low, Siew-Kee; Malinowski, Jennifer; McCarty, Catherine A; Milewicz, Dianna M; Mosley, Thomas H; Nakamura, Yusuke; Nakaoka, Hirofumi; Niemelä, Mika; Pacheco, Jennifer; Peissig, Peggy L; Pera, Joanna; Rasmussen-Torvik, Laura; Ritchie, Marylyn D; Rivadeneira, Fernando; van Rij, Andre M; Santos-Cortez, Regie Lyn P; Saratzis, Athanasios; Slowik, Agnieszka; Takahashi, Atsushi; Tromp, Gerard; Uitterlinden, André G; Verma, Shefali S; Vermeulen, Sita H; Wang, Gao T; Han, Buhm; Rinkel, Gabriël J E; de Bakker, Paul I W

    2016-01-01

    Background--Intracranial aneurysms (IAs), abdominal aortic aneurysms (AAAs), and thoracic aortic aneurysms (TAAs) all have a familial predisposition. Given that aneurysm types are known to co-occur, we hypothesized that there may be shared genetic risk factors for IAs, AAAs, and TAAs. Methods and

  4. Influence of hemodynamic factors on rupture of intracranial aneurysms: patient-specific 3D mirror aneurysms model computational fluid dynamics simulation.

    Science.gov (United States)

    Lu, G; Huang, L; Zhang, X L; Wang, S Z; Hong, Y; Hu, Z; Geng, D Y

    2011-08-01

    Hemodynamics factors play an important role in the rupture of cerebral aneurysms. The purpose of this study was to evaluate the impact of hemodynamic factors on the rupture of the MANs with 3D reconstruction model CFD simulation. RDSA was performed in 9 pairs of intracranial MANs. Each pair was divided into ruptured and unruptured groups. The hemodynamic factors of the aneurysms and their parent arteries were compared. There was a significant difference in the WSS at peak systole between the regions of the aneurysms and their parent arteries in the ruptured group (ie, 6.49 ± 3.48 Pa versus 8.78 ± 3.57 Pa, P =.015) but not in the unruptured group (ie, 9.80 ± 4.12 Pa versus 10.17 ± 7.48 Pa, P =.678). The proportion of the low WSS area to the whole area of the aneurysms was 12.20 ± 18.08% in the ruptured group and 3.96 ± 6.91% in the unruptured group; the difference between the 2 groups was statistically significant (P =.015). The OSI was 0.0879 ± 0.0764 in the ruptured group, which was significantly higher than that of the unruptured group (ie, 0.0183 ± 0.0191, P =.008). MANs may be a useful disease model to investigate possible causes linked to ruptured aneurysms. The ruptured aneurysms manifested lower WSS compared with their parent arteries, a higher proportion of the low WSS area to the whole area of aneurysm, and higher OSI compared with the unruptured aneurysms.

  5. Association Between Vascular Anatomy and Posterior Communicating Artery Aneurysms.

    Science.gov (United States)

    Can, Anil; Ho, Allen L; Emmer, Bart J; Dammers, Ruben; Dirven, Clemens M F; Du, Rose

    2015-11-01

    Hemodynamic stress, conditioned by the geometry and morphology of the vessel trees, plays an important role in the formation of intracranial aneurysms. The aim of this study was to identify image-based location-specific morphologic parameters that are associated with posterior communicating artery (PCoA) aneurysms. Morphologic parameters obtained from computed tomography angiography of 56 patients with PCoA aneurysms and 23 control patients were evaluated with 3D Slicer, an open-source image analysis software, to generate 3-dimensional models of the aneurysms and surrounding vasculature. Segment lengths, diameters, and vessel-to-vessel angles were examined. To control for genetic and clinical risk factors, the unaffected contralateral side of patients with unilateral PCoA aneurysms was used as a control group for internal carotid artery (ICA)-related parameters. A separate control group with visible PCoAs and aneurysms elsewhere was used as a control group for PCoA-related parameters. Internal carotid artery-related parameters were not statistically different between the PCoA aneurysm and control groups. Univariate and multivariate subgroup analysis for patients with visualized PCoAs demonstrated that a larger PCoA diameter was significantly associated with the presence of a PCoA aneurysm (odds ratio = 12.1, 95% confidence interval = 1.3-17.1, P = 0.04) after adjusting for other morphologic parameters. Larger PCoA diameters are associated with the presence of PCoA aneurysms. These parameters may provide objective metrics to assess aneurysm formation and growth risk stratification in high-risk patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Hemodynamics before and after bleb formation in cerebral aneurysms

    Science.gov (United States)

    Cebral, Juan R.; Radaelli, Alessandro; Frangi, Alejandro; Putman, Christopher M.

    2007-03-01

    We investigate whether blebs in cerebral aneurysms form in regions of low or high wall shear stress (WSS), and how the intraaneurysmal hemodynamic pattern changes after bleb formation. Seven intracranial aneurysms harboring well defined blebs were selected from our database and subject-specific computational models were constructed from 3D rotational angiography. For each patient, a second anatomical model representing the aneurysm before bleb formation was constructed by smoothing out the bleb. Computational fluid dynamics simulations were performed under pulsatile flow conditions for both models of each aneurysm. In six of the seven aneurysms, the blebs formed in a region of elevated WSS associated to the inflow jet impaction zone. In one, the bleb formed in a region of low WSS associated to the outflow zone. In this case, the inflow jet maintained a fairly concentrated structure all the way to the outflow zone, while in the other six aneurysms it dispersed after impacting the aneurysm wall. In all aneurysms, once the blebs formed, new flow recirculation regions were formed inside the blebs and the blebs progressed to a state of low WSS. Assuming that blebs form due to a focally damaged arterial wall, these results seem to indicate that the localized injury of the vessel wall may be caused by elevated WSS associated with the inflow jet. However, the final shape of the aneurysm is probably also influenced by the peri-aneurysmal environment that can provide extra structural support via contact with structures such as bone or dura matter.

  7. A coil placement technique to treat intracranial aneurysm with incorporated artery.

    Science.gov (United States)

    Luo, Chao-Bao; Chang, Feng-Chi; Lin, Chung-Jung; Guo, Wan-Yuo

    2018-03-01

    Endovascular coil embolization is an accepted treatment option for intracranial aneurysms. However, the coiling of aneurysms with an incorporated artery (IA) poses a high risk of IA occlusion. Here we report our experience of endovascular coil placement using a technique that avoids IA occlusion in aneurysms with IAs. Over a 6-year period, 185 patients harboring 206 intracranial aneurysms underwent endosaccular coiling. Forty-two of these patients with 45 aneurysms were treated by coil placement to avoid IAs occlusion. We assessed the anatomy of the aneurysms and IAs, technical feasibility of the procedure, and degree of aneurysm occlusion. Clinical and angiographic outcomes were assessed as well. Aneurysms were located in the supra-clinoid intracranial internal carotid artery (n = 24), anterior cerebral artery (n = 6), middle cerebral artery (n = 7), and vertebrobasilar artery (n = 8). The IA was at the aneurysm neck in 34 patients, body in 10, and dome in 1. Immediate post-coiling angiogram showed preservation of blood flow through the IA in all aneurysms. Coil compaction with aneurysmal regrowth was found in 7 of 36 patients having follow-up conventional angiography. One patient had an IA territory infarction after embolization. All 42 patients were followed up (mean: 21 months) and showed no re-bleeding. This technique is effective and safe in managing intracranial aneurysms with IAs. Although aneurysmal recurrence may occur in some aneurysms because of insufficient coiling, this technique is simpler to perform and requires less skill than other techniques. It can be an alternative option for treating some selected intracranial aneurysms with IAs. Copyright © 2017. Published by Elsevier Taiwan LLC.

  8. Intravascular volume after aneurysmal subarachnoid hemorrhage

    NARCIS (Netherlands)

    Hoff, R.G.

    2009-01-01

    Intravascular volume after aneurysmal subarachnoid hemorrhage A subarachnoid hemorrhage (SAH) from a ruptured cerebral aneurysm is a devastating disorder with an often poor prognosis. The occurrence of delayed cerebral ischemia (DCI) is one of the most important factors determining outcome in

  9. Fourier analysis of intracranial aneurysms: towards an objective and quantitative evaluation of the shape of aneurysms

    International Nuclear Information System (INIS)

    Rohde, Stefan; Lahmann, Katharina; Nafe, Reinhold; Yan, Bernard; Berkefeld, Joachim; Beck, Juergen; Raabe, Andreas

    2005-01-01

    Shape irregularities of intracranial aneurysms may indicate an increased risk of rupture. To quantify morphological differences, Fourier analysis of the shape of intracranial aneurysms was introduced. We compared the morphology of 45 unruptured (UIA) and 46 ruptured intracranial aneurysms (RIA) in 70 consecutive patients on the basis of 3D-rotational angiography. Fourier analysis, coefficient of roundness and qualitative shape assessment were determined for each aneurysm. Morphometric analysis revealed significantly smaller coefficient of roundness (P<0.02) and higher values for Fourier amplitudes numbers 2, 3 and 7 (P<0.01) in the RIA group, indicating more complex and irregular morphology in RIA. Qualitative assessment from 3D-reconstructions showed surface irregularities in 78% of RIA and 42% of UIA (P<0.05). Our data have shown significant differences in shape between RIA and UIA, and further developments of Fourier analysis may provide an objective factor for the assessment of the risk of rupture. (orig.)

  10. Application of Revasculization Technique in Aneurysm Surgery : Kyorin University Experience

    OpenAIRE

    栗田, 浩樹; 山口, 竜一; 池田, 俊貴; 原田, 洋一; 塩川, 芳昭; Hiroki, KURITA; Ryuichi, YAMAGUCHI; Toshiki, IKEDA; Youichi, HARADA; Yoshiaki, SHIOKAWA; 杏林大学医学部脳神経外科・脳卒中センター; 杏林大学医学部脳神経外科・脳卒中センター; 杏林大学医学部脳神経外科・脳卒中センター; 杏林大学医学部脳神経外科・脳卒中センター; 杏林大学医学部脳神経外科・脳卒中センター

    2008-01-01

    Between February 2004 and September 2005, revasculization technique was used in 10 patients with intracranial aneurysm to obliterate the aneurysm and to prevent ischemic complications. Five high-flow external carotid-internal carotid (EC-IC) bypasses with radial artery graft (EC-RA-M2) followed by proximal IC occlusion/trapping were used to obliterate unruptured IC-cavernous large/giant aneurysms and ruptured IC anterior wall aneurysms. One patient with ruptured VA-union dissecting aneurysm w...

  11. WEB-DL endovascular treatment of wide-neck bifurcation aneurysms

    DEFF Research Database (Denmark)

    Lubicz, B; Klisch, J; Gauvrit, J-Y

    2014-01-01

    BACKGROUND AND PURPOSE: Flow disruption with the WEB-DL device has been used safely for the treatment of wide-neck bifurcation aneurysms, but the stability of aneurysm occlusion after this treatment is unknown. This retrospective multicenter European study analyzed short- and midterm data...... in patients treated with WEB-DL. MATERIALS AND METHODS: Twelve European neurointerventional centers participated in the study. Clinical data and pre- and postoperative short- and midterm images were collected. An experienced interventional neuroradiologist independently analyzed the images. Aneurysm occlusion...... was classified into 4 grades: complete occlusion, opacification of the proximal recess of the device, neck remnant, and aneurysm remnant. RESULTS: Forty-five patients (34 women and 11 men) 35-74 years of age (mean, 56.3 ± 9.6 years) with 45 aneurysms treated with the WEB device were included. Aneurysm locations...

  12. Transient coronary aneurysm formation after Nevo™ stent implantation versus persistent coronary aneurysm after Cypher Select™ stent implantation

    DEFF Research Database (Denmark)

    Christiansen, Evald Høj; Lassen, Jens Flensted; Jensen, Lisette Okkels

    2011-01-01

    We implanted a Cypher Select™ coronary stent and two months later a Nevo™ sirolimus-eluting coronary stent in another vessel. At a prescheduled angiographic follow-up, coronary aneurysms were seen in the two stented segments, 6 and 8 months after stent implantation, respectively. Six months later......, the aneurysm had healed in the Nevo, but was still present in the Cypher stented segment. We hypothesize that aneurysm formation was induced by sirolimus and the polymer of the implanted stents, and that subsequent healing was possible in the Nevo stent after degradation of the polymer....

  13. Small Intracranial Aneurysm Treatment Using Target (®) Ultrasoft (™) Coils.

    Science.gov (United States)

    Jindal, Gaurav; Miller, Timothy; Iyohe, Moronke; Shivashankar, Ravi; Prasad, Vikram; Gandhi, Dheeraj

    2016-06-01

    The introduction of small, soft, complex-shaped microcoils has helped facilitate the endovascular treatment of small intracranial aneurysms (IAs) over the last several years. Here, we evaluate the initial safety and efficacy of treating small IAs using only Target(®) Ultrasoft(™) coils. A retrospective review of a prospectively maintained clinical database at a single, high volume, teaching hospital was performed from September 2011 to May 2015. IAs smaller than or equal to 5.0 mm in maximal dimension treated with only Target(®) Ultrasoft(™) coils were included. A total of 50 patients with 50 intracranial aneurysms were included. Subarachnoid hemorrhage from index aneurysm rupture was the indication for treatment in 23 of 50 (46%) cases, and prior subarachnoid hemorrhage (SAH) from another aneurysm was the indication for treatment in eight of 50 (16%) cases. The complete aneurysm occlusion rate was 70% (35/50), the minimal residual aneurysm rate was 14% (7/50), and residual aneurysm rate was 16% (8/50). One intraoperative aneurysm rupture occurred. Three patients died during hospitalization from clinical sequelae of subarachnoid hemorrhage. Follow-up at a mean of 13.6 months demonstrated complete aneurysm occlusion in 75% (30/40) of cases, near complete occlusion in 15% (6/40) of cases, and residual aneurysm in 10% (4/40) of cases, all four of which were retreated. Our initial results using only Target(®) Ultrasoft(™) coils for the endovascular treatment of small intracranial aneurysms demonstrate initial excellent safety and efficacy profiles.

  14. Endovascular therapeutic strategies in ruptured intracranial aneurysms

    International Nuclear Information System (INIS)

    Machi, Paolo; Lobotesis, Kyriakos; Vendrell, Jean Francoise; Riquelme, Carlos; Eker, Omer; Costalat, Vincent; Bonafe, Alain

    2013-01-01

    The aim of the present study was to evaluate endovascular techniques used currently which were not available at the time of ISAT inclusion period, such as balloon remodelling and flow-divertion, in order to assess whether these new technologies have improved the endovascular approach outcomes. We present a review of articles, published in major journals, with the aim to evaluate the efficacy and the safety of coiling with balloon remodelling for the treatment of ruptured aneurysms in comparison to coiling performed without such coadjutant techniques. Furthermore, we reviewed publications reporting on the treatment of ruptured aneurysms in the acute phase with the one of the most recent technologies available nowadays: the flow diverting stent. Looking at the recent literature the results regarding ruptured aneurysms treated with balloon assisted coiling (BAC) have shown an improvement in terms of anatomical results and morbi-mortality rates. Case series of ruptured middle cerebral artery (MCA) aneurysms treated by EVT report results similar to those obtained by surgical clipping. Several articles recently report encouraging results in treating ruptured dissecting and blister aneurysms with flow diverters. Questions regarding the best treatment available for ruptured aneurysms are yet to be answered. Hence there is a need for a subsequent trial aiming to answer these unresolved issues

  15. Cranio-orbital approach for complex aneurysmal surgery.

    LENUS (Irish Health Repository)

    Kelleher, M O

    2012-02-03

    Certain aneurysms of the anterior circulation continue to offer a technical challenge for safe exposure and clipping. The purpose of this paper was to describe the cranio-orbital approach for surgical clipping of complex aneurysms and to evaluate prospectively the associated complications of this approach. Prospective audit of all patients undergoing cranio-orbital approach for aneurysm surgery from 1997 to 2004 by the senior author. Twenty-five patients, eight male and 17 female, median age of 52 years, range 28-73. All patients had a standard pterional approach supplemented by an orbital osteotomy. In the 7-year period 367 patients underwent treatment for their aneurysms (169 clipped and 198 coiled). Of the 169 patients who were operated on, 29 had a skull base approach, of which 25 were cranio-orbital. The aneurysm location was as follows: 16 middle cerebral artery (MCA), three carotid bifurcation, four anterior communicating artery (ACOMM), one ophthalmic and one basilar. There were no approach-related complications. The cranio-orbital craniotomy can be a useful adjunct in the surgical treatment of giant or complex aneurysms. It offers the following advantages over a standard pterional approach: reduces operative distance; allows easy splitting of the sylvian fissure; and provides a wide arc of exposure with multiple working corridors.

  16. Vortex dynamics in ruptured and unruptured intracranial aneurysms

    Science.gov (United States)

    Trylesinski, Gabriel

    Intracranial aneurysms (IAs) are a potentially devastating pathological dilation of brain arteries that affect 1.5-5 % of the population. Causing around 500 000 deaths per year worldwide, their detection and treatment to prevent rupture is critical. Multiple recent studies have tried to find a hemodynamics predictor of aneurysm rupture, but concluded with distinct opposite trends using Wall Shear Stress (WSS) based parameters in different clinical datasets. Nevertheless, several research groups tend to converge for now on the fact that the flow patterns and flow dynamics of the ruptured aneurysms are complex and unstable. Following this idea, we investigated the vortex properties of both unruptured and ruptured cerebral aneurysms. A brief comparison of two Eulerian vortex visualization methods (Q-criterion and lambda 2 method) showed that these approaches gave similar results in our complex aneurysm geometries. We were then able to apply either one of them to a large dataset of 74 patient specific cases of intracranial aneurysms. Those real cases were obtained by 3D angiography, numerical reconstruction of the geometry, and then pulsatile CFD simulation before post-processing with the mentioned vortex visualization tools. First we tested the two Eulerian methods on a few cases to verify their implementation we made as well as compare them with each other. After that, the Q-criterion was selected as method of choice for its more obvious physical meaning (it shows the balance between two characteristics of the flow, its swirling and deformation). Using iso-surfaces of Q, we started by categorizing the patient-specific aneurysms based on the gross topology of the aneurysmal vortices. This approach being unfruitful, we found a new vortex-based characteristic property of ruptured aneurysms to stratify the rupture risk of IAs that we called the Wall-Kissing Vortices, or WKV. We observed that most ruptured aneurysms had a large amount of WKV, which appears to agree with

  17. Coiling of ruptured pericallosal artery aneurysms.

    NARCIS (Netherlands)

    Menovsky, T.; Rooij, W.J.J. van; Sluzewski, M.; Wijnalda, D.

    2002-01-01

    OBJECTIVE: To assess the technical feasibility of treating ruptured pericallosal artery aneurysms with detachable coils and to evaluate the anatomic and clinical results. METHODS: Over a period of 27 months, 12 patients with a ruptured pericallosal artery aneurysm were treated with detachable

  18. Rupture of popliteal arterial aneurysm due to salmonella infection

    International Nuclear Information System (INIS)

    Kim, Dong Hun; Oh, Hyung Woo; Kim, Dong Hyun; Byun, Joo Nam

    2006-01-01

    We report here on a case of popliteal aneurysm and rupture that occurred over a 10-day period and this was all secondary to salmonella infection. Computed tomography (CT) angiography of the extremity that was performed before and after aneurysmal rupture showed the aneurysm's rapid evolution to rupture over a short period of time. We also review the pathogenesis, clinical presentation, diagnostic approach and management of salmonella aneurysms

  19. Phantom pain and phantom sensations in upper limb amputees : an epidemiological study

    NARCIS (Netherlands)

    Kooijman, CM; Dijkstra, PU; Geertzen, JHB; Elzinga, A; van der Schans, CP

    Phantom pain in subjects with an amputated limb is a well-known problem. However, estimates of the prevalence of phantom pain differ considerably in the literature. Various factors associated with phantom pain have been described including pain before the amputation, gender, dominance, and time

  20. Individual virtual phantom reconstruction for organ dosimetry based on standard available phantoms

    International Nuclear Information System (INIS)

    Babapour Mofrad, F.; Aghaeizadeh Zoroofi, R.; Abbaspour Tehran Fard, A.; Akhlaghpoor, Sh.; Chen, Y. W.; Sato, Y.

    2010-01-01

    In nuclear medicine application often it is required to use computational methods for evaluation of organ absorbed dose. Monte Carlo Simulation and phantoms have been used in many works before. The shape, size and volume In organs are varied, and this variation will produce error in dose calculation if no correction is applied. Materials and Methods: A computational framework for constructing individual phantom for dosimetry was performed on five liver CT scan data sets of Japanese normal individuals. The Zubal phantom was used as an original phantom to be adjusted by each individual data set. This registration was done by Spherical Harmonics and Thin-Plate Spline methods. Hausdorff distance was calculated for each case. Results: Result of Hausdorff distance for five lndividual phantoms showed that before registration ranged from 140.9 to 192.1, and after registration it changed to 52.5 to 76.7. This was caused by Index similarity ranged from %56.4 to %70.3. Conclusion: A new and automatic three-dimensional (3D) phantom construction approach was-suggested for individual internal dosimetry simulation via Spherical Harmonics and Thin-Plate Spline methods. The results showed that the Individual comparable phantom can be calculated with acceptable accuracy using geometric registration. This method could be used for race-specific statistical phantom modeling with major application in nuclear medicine for absorbed dose calculation.

  1. Endothelial cell proliferation in swine experimental aneurysm after coil embolization.

    Directory of Open Access Journals (Sweden)

    Yumiko Mitome-Mishima

    Full Text Available After coil embolization, recanalization in cerebral aneurysms adversely influences long-term prognosis. Proliferation of endothelial cells on the coil surface may reduce the incidence of recanalization and further improve outcomes after coil embolization. We aimed to map the expression of proliferating tissue over the aneurysmal orifice and define the temporal profile of tissue growth in a swine experimental aneurysm model. We compared the outcomes after spontaneous thrombosis with those of coil embolization using histological and morphological techniques. In aneurysms that we not coiled, spontaneous thrombosis was observed, and weak, easily detachable proliferating tissue was evident in the aneurysmal neck. In contrast, in the coil embolization group, histological analysis showed endothelial-like cells lining the aneurysmal opening. Moreover, immunohistochemical and morphological analysis suggested that these cells were immature endothelial cells. Our results indicated the existence of endothelial cell proliferation 1 week after coil embolization and showed immature endothelial cells in septal tissue between the systemic circulation and the aneurysm. These findings suggest that endothelial cells are lead to and proliferate in the former aneurysmal orifice. This is the first examination to evaluate the temporal change of proliferating tissue in a swine experimental aneurysm model.

  2. Follow-up observation of intracranial aneurysms with Guglielmi detachable coil embolization

    International Nuclear Information System (INIS)

    Li Minghua; Cheng Yingsheng; Gu Binxian; Chen Junyan; Wang Wu; Xu Tao; Xu Shiding; Liu Jianmin; Xu Yi

    2002-01-01

    Objective: To evaluate the middle-long term efficacy of intracranial aneurysms with Guglielmi detachable Coil (GDC) embolization. Methods: 131 cases with 134 aneurysms were embolized with GDC. Of them, 39 aneurysms were in the anterior communication artery, 45 in the posterior communication artery, 19 in the siphon segment of internal carotid artery, 14 in the mediate cerebral artery, 3 in the anterior cerebral artery, 9 in the posterior circle and 5 in other. A wide-neck (neck > 4 mm, or aneurysm body/neck 2 = 8.643, P < 0.01. Follow-up DSA showed no change in 118 aneurysms which were a total or nearly total occlusion on post-embolization DSA. In 16 aneurysms with subtotal or partial occlusion, re-open of aneurysm showed in 9 cases, reduced in 3, no change in 4 on follow-up DSA. Conclusion: Although the recent-medium-term efficacy of intracranial aneurysms with GDC embolization is in the affirmative, a period follow-up DSA is essential, especially in aneurysms with subtotal or partial occlusion. Again, re-embolization with GDC is recommended in a re-open aneurysm

  3. Correlation between the clinical presentation and DSA of intracranial aneurysms

    International Nuclear Information System (INIS)

    Fang Chun; Hua Jia; Chen Kemin; Yin Yan; Ge Xin; Ying Yiping

    2001-01-01

    Objective: To evaluate the correlation between the clinical presentation and cerebral angiographic features of intracranial aneurysms. Methods: The authors retrospectively analyzed the relationship between the size, location and shape of 48 patient's cerebral aneurysms and their clinical presentations. Results: Clinical symptoms of cerebral aneurysms were related with their size, location and shape. Aneurysms in different location or at same location may cause similar symptoms or different symptoms. Rotation DSA is a useful examination supplemented to conventional DSA. Conclusions: The relationship between the location and the presentation of intracranial aneurysms is not specific. Rotation DSA plays important role in showing the characteristics of the cerebral aneurysms

  4. ADAMTS-1 in abdominal aortic aneurysm.

    Directory of Open Access Journals (Sweden)

    Emina Vorkapic

    Full Text Available Extracellular matrix degradation is a hallmark of abdominal aortic aneurysm (AAA. Among proteases that are capable of degrading extracellular matrix are a disintegrin and metalloproteases with thrombospondin motifs (ADAMTS. Pathogenesis of these proteases in AAA has not been investigated until date.Human aneurysmal and control aortas were collected and analyzed with RT-PCR measuring the ADAMTS-1, 4,5,6,8,9,10,13,17 and ADAMTSL-1. Expression of a majority of the investigated ADAMTS members on mRNA level was decreased in aneurysm compared to control aorta. ADAMTS-1 was one of the members that was reduced most. Protein analysis using immunohistochemistry and western blot for localization and expression of ADAMTS-1 revealed that ADAMTS-1 was present predominantly in areas of SMCs and macrophages in aneurysmal aorta and higher expressed in AAA compared to control aortas. The role of ADAMTS-1 in AAA disease was further examined using ADAMTS-1 transgenic/apoE-/- mice with the experimental angiotensin II induced aneurysmal model. Transgenic mice overexpressing ADAMTS-1 showed to be similar to ADAMTS-1 wild type mice pertaining collagen, elastin content and aortic diameter.Several of the ADAMTS members, and especially ADAMTS-1, are down regulated at mRNA level in AAA, due to unknown mechanisms, at the same time ADAMTS-1 protein is induced. The cleavage of its substrates, don't seem to be crucial for the pathogenesis of AAA but rather more important in the development of thoracic aortic aneurysm and atherosclerosis as shown in previous studies.

  5. Aneurysm Repair

    Science.gov (United States)

    ... the aneurysm. The stent graft acts as a barrier between the blood and the diseased wall of ... Search THI Resources Office of Research Administration Library & Learning Resource Center Scientific Publications & Grants Visual Communications & Public ...

  6. True aneurysm of the proximal occipital artery: Case report

    Directory of Open Access Journals (Sweden)

    Giulio Illuminati

    Full Text Available Introduction: True aneurysms of the proximal occipital artery are rare, may cause neurological symptoms due to compression of the hypoglossal nerve and their resection may be technically demanding. Presentation of case: The case of an aneurysm of the proximal occipital artery causing discomfort and tongue deviation by compression on the hypoglossal nerve is reported. Postoperative course after resection was followed by complete regression of symptoms. Conclusion: Surgical resection, as standard treatment of aneurysms of the occipital artery, with the eventual technical adjunct of intubation by the nose is effective in durably relieving symptoms and preventing aneurysm-related complication. Keywords: Arterial aneurysm, Occipital artery, Case report

  7. Endovascular treatment of posterior cerebral artery aneurysms using detachable coils

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Hong Gee [Kangwon National University Hospital, Department of Radiology, Chuncheon, Kangwon-do (Korea); Konkuk University Hospital, Department of Radiology, Seoul (Korea); Kim, Sam Soo; Han, Heon [Kangwon National University Hospital, Department of Radiology, Chuncheon, Kangwon-do (Korea); Kang, Hyun-Seung [Konkuk University Hospital, Department of Neurosurgery, Seoul (Korea); Moon, Won-Jin [Konkuk University Hospital, Department of Radiology, Seoul (Korea); Byun, Hong Sik [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea)

    2008-03-15

    Aneurysms of the posterior cerebral artery (PCA) are rare, and most of the studies reported in the literature in which the endovascular approach was applied were carried out on a limited number of patients with PCA aneurysms. We retrospectively reviewed our cases of PCA aneurysms - at various locations and of differing shapes - that received endovascular treatment and evaluated the treatment outcome. From January 1996 to December 2006, 13 patients (eight females and five males) with 17 PCA aneurysms (nine fusiform and eight saccular) were treated using the endovascular approach. The age of the patients ranged from 20 to 67 years, with a mean age of 44 years. Of the 13 patients, ten presented with intracranial hemorrhage, and one patient, with a large P2 aneurysm, presented with trigeminal neuralgia; the aneurysms were asymptomatic in the remaining two patients. All 13 patients were successfully treated, with only one procedure-related symptomatic complication. Seven patients were treated by occlusion of the aneurysm and parent artery together; five patients, by selective embolization of the aneurysm; one patient, by partial coiling. Although infarctions were found in two patients treated with selective embolization and in three patients treated with parent artery occlusion, only one patient with a ruptured P2 aneurysm treated with parent artery occlusion developed transient amnesia as an ischemic symptom. Posterior cerebral artery aneurysms can be treated safely with either occlusion of the aneurysm together with the PCA or with a selective coil embolization. Infarctions may occur after endovascular treatment, but they are rarely the cause of a disabling symptom. (orig.)

  8. Bilateral Distal Anterior Cerebral Artery Aneurysms Mimicking So-called "Kissing Aneurysms": A Case Report

    OpenAIRE

    山口, 竜一; 伊藤, 宣行; 前村, 栄治; 塩川, 芳昭; 齋藤, 勇; Ryuichi, YAMAGUCHI; Nobuyuki, ITO; Eiji, MAEMURA; Yoshiaki, SHIOKAWA; Isamu, SAITO; 公立阿伎留病院脳神経外科; 公立阿伎留病院脳神経外科; 公立阿伎留病院脳神経外科; 杏林大学医学部脳神経外科; 杏林大学医学部脳神経外科

    2003-01-01

    A 71-year-old woman presented disturbance of consciousness due to subarachnoid hemorrhage (SAH). A computed tomography (CT) on admission revealed diffuse thick SAH and intracerebral hematoma in the right frontal lobe. Conventional angiography and three-dimensional CT angiography showed symmetrical aneurysms located on the bilateral pericallosal arteries at bifurcation of the callosomarginal arteries. The operation was performed on the next day after onset of SAH. The aneurysms were clipped vi...

  9. Intrinsic, Transitional, and Extrinsic Morphological Factors Associated With Rupture of Intracranial Aneurysms.

    Science.gov (United States)

    Ho, Allen L; Lin, Ning; Frerichs, Kai U; Du, Rose

    2015-09-01

    As diagnosis and treatment of unruptured intracranial aneurysms continues to increase, management principles remain largely based on size. This is despite mounting evidence that aneurysm location and other morphologic variables could play a role in predicting overall risk of rupture. Morphological parameters can be divided into 3 main groups, those that are intrinsic to the aneurysm, those that are extrinsic to the aneurysm, and those that involve both the aneurysm and surrounding vasculature (transitional). We present an evaluation of intrinsic, transitional, and extrinsic factors and their association with ruptured aneurysms. Using preoperative computed tomographic angiography, we generated 3-dimensional models of aneurysms and their surrounding vasculature with Slicer software. Using univariate and multivariate analyses, we examined the association of intrinsic, transitional, and extrinsic aspects of aneurysm morphology with rupture. Between 2005 and 2013, 227 cerebral aneurysms in 4 locations were evaluated/treated at a single institution, and computed tomographic angiographies of 218 patients (97 unruptured and 130 ruptured) were analyzed. Ruptured aneurysms analyzed were associated with clinical factors of absence of multiple aneurysms and history of no prior rupture, and morphologic factors of greater aspect ratio. On multivariate analysis, aneurysm rupture remained associated with history of no prior rupture, greater flow angle, greater daughter-daughter vessel angle, and smaller parent-daughter vessel angle. By studying the morphology of aneurysms and their surrounding vasculature, we identified several parameters associated with ruptured aneurysms that include intrinsic, transitional, and extrinsic factors of cerebral aneurysms and their surrounding vasculature.

  10. 911 Call Center (PSAP) Service Areas, Master coverage of "atom" features used as a source to generate several derivative layers for the Sheriff RMS and E-911 map rolls. Cover is painstakingly maintained interactively by GIS staff. All atom boundaries are snapped to the road centerline cover, Published in 2008, 1:1200 (1in=100ft) scale, Sedgwick County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — 911 Call Center (PSAP) Service Areas dataset current as of 2008. Master coverage of "atom" features used as a source to generate several derivative layers for the...

  11. Intracranial aneurysms: optimized diagnostic tools call for thorough interdisciplinary treatment strategies.

    Science.gov (United States)

    Mueller, Oliver M; Schlamann, Marc; Mueller, Daniela; Sandalcioglu, I Erol; Forsting, Michael; Sure, Ulrich

    2011-09-01

    Intracranial aneurysms (IAs) require deliberately selected treatment strategies as they are incrementally found prior to rupture and deleterious subarachnoid haemorrhage (SAH). Multiple and recurrent aneurysms necessitate both neurointerventionalists and neurosurgeons to optimize aneurysmal occlusion in an interdisciplinary effort. The present study was conducted to condense essential strategies from a single neurovascular centre with regard to the lessons learned. Medical charts of 321 consecutive patients treated for IAs at our centre from September 2008 until December 2010 were retrospectively analysed for clinical presentation of the aneurysms, multiplicity and treatment pathways. In addition, a selective Medline search was performed. A total of 321 patients with 492 aneurysms underwent occlusion of their symptomatic aneurysm: 132 (41.1%) individuals were treated surgically, 189 (58.2%) interventionally; 138 patients presented with a SAH, of these 44.2% were clipped and 55.8% were coiled. Aneurysms of the middle cerebral artery were primarily occluded surgically (88), whereas most of the aneurysms of the internal carotid artery and anterior communicating artery (114) were treated endovascularly. Multiple aneurysms (range 2-5 aneurysms/individual) were diagnosed in 98 patients (30.2%). During the study period 12 patients with recurrent aneurysms were allocated to another treatment modality (previously clip to coil and vice versa). Our data show that successful interdisciplinary occlusion of IAs is based on both neurosurgical and neurointerventional therapy. In particular, multiple and recurrent aneurysms require tailored individual approaches to aneurysmal occlusion. This is achieved by a consequent interdisciplinary pondering of the optimal strategy to occlude IAs in order to prevent SAH.

  12. Experimental Study of Flow Through Carotid Aneurysms

    Science.gov (United States)

    Masoomi, Faezeh; Mejia-Alvarez, Ricardo

    2017-11-01

    There is evidence that traditional endovascular techniques like coiling are not effective for treatment of wide-neck cerebral aneurysms. Flow Diverter Stents (FDS) have emerged as promising devices for treating complex aneurysms since they enable treatment of aneurysms that were considered untreatable before. Recent studies suggest a number of associated risks with FDS, including in-stent thrombosis, perianeurysmal edema, delayed hemorrhage, and perforator occlusions. Chong et al. simulated hemodynamic behavior using patient-specific data. From their study, it is possible to infer that the standard deviation of energy loss could be a good predictor for intervention success. The aim of this study is to investigate the flow in models of cerebral aneurysms before and after FDS insertion using PIV. These models will be based on actual clinical studies and will be fabricated with advanced additive manufacturing techniques. These data will then be used to explore flow parameters that could inform the likelihood of post-intervention aneurysm rupture, and help determine FDS designs that better suit any particular patient before its procedure.

  13. Hemodynamic alterations after stent implantation in 15 cases of intracranial aneurysm.

    Science.gov (United States)

    Wang, Chao; Tian, Zhongbin; Liu, Jian; Jing, Linkai; Paliwal, Nikhil; Wang, Shengzhang; Zhang, Ying; Xiang, Jianping; Siddiqui, Adnan H; Meng, Hui; Yang, Xinjian

    2016-04-01

    Stent-assisted coiling technology has been widely used in the treatment of intracranial aneurysms. In the current study, we investigated the intra-aneurysmal hemodynamic alterations after stent implantation and their association with the aneurysm location. We first retrospectively studied 15 aneurysm cases [8 internal carotid artery-ophthalmic artery (ICA-OphA) aneurysms and 7 posterior communicating artery (PcoA) aneurysms] treated with Enterprise stents and coils. Then, based on the patient-specific geometries before and after stenting, we built virtual stenting computational fluid dynamics (CFD) simulation models. Before and after the stent deployment, the average wall shear stress (WSS) on the aneurysmal sac at systolic peak changed from 7.04 Pa (4.14 Pa, 15.77 Pa) to 6.04 Pa (3.86 Pa, 11.13 Pa), P = 0.001; the spatially averaged flow velocity in the perpendicular plane of the aneurysm dropped from 0.5 m/s (0.28 m/s, 0.7 m/s) to 0.33 m/s (0.25 m/s, 0.49 m/s), P = 0.001, respectively. Post stent implantation, the WSS in ICA-OphA aneurysms and PcoA aneurysms decreased by 14.4 % (P = 0.012) and 16.6 % (P = 0.018), respectively, and the flow velocity also reduced by 10.3 % (P = 0.029) and 10.5 % (P = 0.013), respectively. Changes in the WSS, flow velocity, and pressure were not significantly different between ICA-OphA and PcoA aneurysms (P > 0.05). Stent implantation did not significantly change the peak systolic pressure in either aneurysm type. After the stent implantation, both the intra-aneurysmal flow velocity and WSS decreased independently of aneurysm type (ICA-OphA and PcoA). Little change was observed in peak systolic pressure.

  14. Stent-assisted coil embolization of intracranial aneurysms: a single center experience.

    Science.gov (United States)

    Luo, Chao-Bao; Teng, Michael Mu-Huo; Chang, Feng-Chi; Lin, Chung-Jung; Guo, Wan-Yuo; Chang, Cheng-Yen

    2012-07-01

    Endovascular detachable coil embolization has become an important method in the management of intracranial aneurysms. However, coil embolization alone may fail to treat some wide-neck aneurysms. Herein, we report our experience with and outcome of stent-assisted coil embolization (SACE) of intracranial aneurysms. Over a 5-year period, a total of 59 patients diagnosed with 63 intracranial aneurysms underwent SACE. Of the total 63 aneurysms, 6 aneurysms were treated by SACE as a salvageable procedure because of coil instability after detachment. There were 17 men and 42 women enrolled in the study, with ages ranging from 24 to 86 years (mean: 60 years). We retrospectively assessed the clinical data, aneurysm characteristics, and angiographic and clinical outcomes of all patient cases. The mean aneurysm size was 9.4 mm, and the mean neck size was 5.5 mm. Clinical and angiographic follow-up exceeding 6 months were available in 51 and 40 patients, respectively. The mean clinical follow-up time was 28 months (range: 6-49 months). Successful stent deployment was found in 60 aneurysms (95%). Midterm total or subtotal angiographic aneurismal occlusion was obtained in 56 aneurysms (89%), with further thrombosis of the aneurismal sac occurring in 4 (10%). Stable coiling aneurysm was found in 24 (78%), aneurysm recurrence was observed in 5 (13%), and permanent procedural morbidity was observed in two patients (3.4%). During the follow-up period, there were no hemorrhagic events and no stent displacement. Despite a modest procedural complication rate, and some evidence of aneurismal recurrence, SACE was proved to be both effective and safe in managing wide-neck intracranial aneurysms. Our results also demonstrated the midterm durability and stability of aneurysm treated by SACE. Furthermore, SACE can be a salvageable procedure in cases with coil instability after detachment. Copyright © 2012. Published by Elsevier B.V.

  15. De novo giant A2 aneurysm following anterior communicating artery occlusion.

    Science.gov (United States)

    Ibrahim, Tarik F; Hafez, Ahmad; Andrade-Barazarte, Hugo; Raj, Rahul; Niemela, Mika; Lehto, Hanna; Numminen, Jussi; Jarvelainen, Juha; Hernesniemi, Juha

    2015-01-01

    De novo intracranial aneurysms are reported to occur with varying incidence after intracranial aneurysm treatment. They are purported to be observed, however, with increased incidence after Hunterian ligation; particularly in cases of carotid artery occlusion for giant or complex aneurysms deemed unclippable. We report a case of right-sided de novo giant A2 aneurysm 6 years after an anterior communicating artery (ACoA) aneurysm clipping. We believe this de novo aneurysm developed in part due to patient-specific risk factors but also a significant change in cerebral hemodynamics. The ACoA became occluded after surgery that likely altered the cerebral hemodynamics and contributed to the de novo aneurysm. We believe this to be the first reported case of a giant de novo aneurysm in this location. Following parent vessel occlusion (mostly of the carotid artery), there are no reports of any de novo aneurysms in the pericallosal arteries let alone a giant one. The patient had a dominant right A1 and the sudden increase in A2 blood flow likely resulted in increased wall shear stress, particularly in the medial wall of the A2 where the aneurysm occurred 2 mm distal to the A1-2 junction. ACoA preservation is a key element of aneurysm surgery in this location. Suspected occlusion of this vessel may warrant closer radiographic follow-up in patients with other risk factors for aneurysm development.

  16. Endovascular treatment of the posterior inferior cerebellar artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Bradac, G.B.; Bergui, M. [Neuroradiology, Univ. di Torino, Turin (Italy)

    2004-12-01

    Aneurysms may arise at various locations along the course of the posterior inferior cerebellar artery. Brainstem and cranial nerves manipulation make the surgical approach to proximal aneurysms difficult, while the occlusion of the parent vessel is sometimes unavoidable in peripheral aneurysms. Endovascular treatment can be a good alternative, but also with this approach the location of the aneurysm is critical. If occlusion of the parent vessel is planned, anatomical variations and vascular territories of the brainstem should be considered. We report our experience with 18 consecutive aneurysms (12 proximal, 6 peripheral) treated by coils. Complete occlusion was achieved in 14 patients and subtotal in 4. In three patients the parent vessel had to be sacrificed. During treatment two perforations occurred; aneurysms were completely occluded without clinical consequences. Two small asymptomatic cerebellar infarctions were seen on postoperative computed tomography. Clinical outcome was good in 16 patients. (orig.)

  17. Prediction of parent artery of anterior communicating artery aneurysm on CT angiography

    International Nuclear Information System (INIS)

    Chung, Jin Young; Han, Tae Il; Kim, Dae Hong; Han, Hyun Young; Kim, Hyun Jung; Song, Mun Kab

    1999-01-01

    To determine whether CT angiography can predict the parent artery of an anterior communicating aneurysm on the basis of characteristics of the aneurysm and precommunication anterior cerebral artery. Eighteen patients with anterior communication aneurysm were studied prospectively using CT angiography and conventional angiography. The parent artery of an aneurysm was predicted by evaluating aneurysm neck location, direction of aneurysm projection, and size of the precommunicating anterior cerebral artery, as seen on CT angiography. A somatom Plus-4 spiral CT scanner was used and shaded-surface display three-dimensional images were constructed. Aneurysm neck was located near the parent artery in 12 cases(66.7%), and aneurysm projection was against the parent artery in 11 cases(61.1%). The parent artery of the anterior cerebral artery was larger in 15 cases(83.3%), including ten cases of hypoplasia or agenesis of the contralateral anterior cerebral artery. In 17 of 18 aneurysms(94.4%) the parent artery seen on DSA was correctly predicted by CT angiography. The parent artery of an anterior communicating aneurysm can be predicted by evaluating aneurysm neck location, direction of aneurysm projection, and precommunicating anterior cerebral artery, as seen on CT angiography

  18. Aneurysm-Specific miR-221 and miR-146a Participates in Human Thoracic and Abdominal Aortic Aneurysms

    Directory of Open Access Journals (Sweden)

    Premakumari Venkatesh

    2017-04-01

    Full Text Available Altered microRNA expression is implicated in cardiovascular diseases. Our objective was to determine microRNA signatures in thoracic aortic aneurysms (TAAs and abdominal aortic aneurysms (AAAs compared with control non-aneurysmal aortic specimens. We evaluated the expression of fifteen selected microRNA in human TAA and AAA operative specimens compared to controls. We observed significant upregulation of miR-221 and downregulation of miR-1 and -133 in TAA specimens. In contrast, upregulation of miR-146a and downregulation of miR-145 and -331-3p were found only for AAA specimens. Upregulation of miR-126 and -486-5p and downregulation of miR-30c-2*, -155, and -204 were observed in specimens of TAAs and AAAs. The data reveal microRNA expression signatures unique to aneurysm location and common to both thoracic and abdominal pathologies. Thus, changes in miR-1, -29a, -133a, and -221 are involved in TAAs and miR-145, -146, and -331-3p impact AAAs. This work validates prior studies on microRNA expression in aneurysmal diseases.

  19. Diagnosis and treatment of traumatic intracranial aneurysm in childhood

    International Nuclear Information System (INIS)

    Yu Juming; Fan Guoping; Zhong Weixing; Zhang Yongping; Peng Haiteng; Zhu Ming; Cheng Yongde

    2008-01-01

    Objective: To evaluate the diagnosis, safety and efficacy of interventional therapy and surgery for child traumatic intracranial aneurysms. Methods: Five patients with traumatic intracranial aneurysms including three males and two females, age ranged from 2 to 10 years old; 5 had undertaken CT and MR scanings. All of them showed traumatic subarachnoid hemorrhage in 2, intracerebral hematoma in the right occipital and the left temporal respectively in 2 and another one with somewhat bleeding at the posterior fossa and right trigone of lateral ventricles and subdural bleeding at the tentorium edge. The detailed vascular involvement diagnosis were made by DSA revealing one of left C1 segmental internal carotid artery traumatic aneurysm, one of the branch of right sylvian artery traumatic aneurysm, one of left middle cerebral artery traumatic aneurysm, one of left posterior cerebral artery traumatic aneurysm, one of the branch of right posterior inferior cerebellar artery traumatic aneurysm. Two of them were treated by embolization therapy with CDC and two by surgery. Results: The CDC embolization in 2 cases and the surgical operation for another 2 were all succeeded without death or complications. The last case was followed up closely. Conclusions: Traumatic intracranial aneurysm is rare in childhood but endovascular treatment with CDC and surgery is efficient and safe, yet the long-term efficacy is still relied on follow-up. (authors)

  20. Spontaneous non aneurysmal subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Bian Jieyong; Wang Zhong; Zhou Dai

    2000-01-01

    Objective: To study the etiology and the treatment of spontaneous non-aneurysmal subarachnoid hemorrhage. Methods: Twenty five cases of cerebral vessel angiography negative patients were analysed retrospectively, the majority of them had been undergone CT, DSA, MRI examination in order to define the etiological factor. Results: Among them, there was 1 case of spinal arteria-vena malformation, 1 case of hemorrhagic blood and 2 cases according to the revealing of MRI could be explained as bled vascular-occult malformation or cavernous angioma. Conclusion: The management and prognosis of patients in whom non-aneurysm is founded on the initial angiogram depends on the pattern of hemorrhage of the initial CT scanning, repeated angiography should be avoided for the case of premise encephalic non-aneurysmal SAH and MRI examination may be indicated to defining of etiological factors

  1. Hypertrophic cardiomyopathy with mid-ventricular obstruction and apical aneurysm

    Directory of Open Access Journals (Sweden)

    N.D. Oryshchyn

    2016-11-01

    Full Text Available A case report of apical left ventricular aneurysm in patient with hypertrophic cardiomyopathy with mid-ventricular obstruction (diagnosis and surgical treatment is presented. We revealed apical aneurysm and mid-ventricular obstruction during echocardiography and specified anatomical characteristics of aneurysm during computer tomography. There was no evidence of obstructive coronary artery disease during coronary angiography. Taking into consideration multiple cerebral infarcts, aneurysm resection and left ventricular plastics was performed. Electronic microscopy of myocardium confirmed the diagnosis of hypertrophic cardiomyopathy.

  2. Comparative evaluation of cerebral aneurysms with selective arterially enhanced CT and DSA

    International Nuclear Information System (INIS)

    Vanderschelden, P.; Flandroy, P.; Dondelinger, R.F.; Martin, D.; Lenelle, J.

    1998-01-01

    The purpose of our study was to compare selective arterially enhanced spiral computed tomographs (ACT) with digital subtraction angiographies (DSA) in the presurgical assessment of cerebral aneurysms. A total of 24 aneurysms in 18 patients were explored in a prospective study by ACT and DSA, using an interactive combined CT-angiography suite. Dimensions of the aneurysm, its relation to the parent vessel, and the aneurysmal index were defined on DSA and on surface-shaded display of 3D reformatted images obtained from ACT. Results were correlated with surgical findings. Three aneurysms suspected on DSA were not confirmed by ACT. One fusiform aneurysm suspected on DSA corresponded to a sacciform aneurysm on ACT. Surgical findings confirmed 20 sacciform aneurysms. The aneurysmal index could be measured in all 20 cases of sacciform aneurysms on ACT and could not be determined with confidence in 55 % of the cases on DSA. DSA and ACT gave identical results in 35 % of cases. In 10 %, the index measured by ACT was superior to that determined by DSA for aneurysms which had a diameter of less than 3 mm. In conclusion, the combination of DSA and ACT improved the results of DSA alone. ACT is a reliable method to measure the aneurysmal index in aneurysms with a diameter superior to 3 mm. (orig.)

  3. Flow diversion in vasculitic intracranial aneurysms? Repair of giant complex cavernous carotid aneurysm in polyarteritis nodosa using Pipeline embolization devices: first reported case.

    Science.gov (United States)

    Martinez Santos, Jaime; Kaderali, Zul; Spears, Julian; Rubin, Laurence A; Marotta, Thomas R

    2016-07-01

    Intracranial aneurysms in polyarteritis nodosa (PAN) are exceedingly rare lesions with unpredictable behavior that pose real challenges to microsurgical and endovascular interventions owing to their inflammatory nature. We introduce a safe and effective alternative for treating these aneurysms using Pipeline embolization devices (PEDs). A 20-year-old man presented with diplopia, headaches, chronic abdominal pain, and weight loss. Diagnostic evaluations confirmed PAN, including bilateral giant cavernous carotid aneurysms. Cyclophosphamide and steroids achieved significant and sustained clinical improvement, with a decision to follow the aneurysms serially. Seven years later the left unruptured aneurysm enlarged, causing a sudden severe headache and a cavernous sinus syndrome. Treatment of the symptomatic aneurysm was pursued using flow diversion (PED) and the internal carotid artery was successfully reconstructed with a total of four overlapping PEDs. At 6 months follow-up, complete exclusion of the aneurysm was demonstrated, with symptomatic recovery. This is the first description of using a flow-diverting technique in an inflammatory vasculitis. In this case, PEDs not only attained a definitive closure of the aneurysm but also reconstructed the damaged and fragile arterial segment affected with vasculitis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. Portal circulation aneurysms: two case reviews

    International Nuclear Information System (INIS)

    Perret, W. L.; Silva, A de.; Elzarka, A.; Schelleman, A.

    2007-01-01

    Venous aneurysms of the superior mesenteric vein and portal vein are an uncommon occurrence and often an incidental finding. They can also be associated with hepatocellular disease and portal hypertension. We present CT and ultrasound findings of these entities. The management of venous aneurysms is generally conservative with serial imaging

  5. Transluminal color-coded three-dimensional magnetic resonance angiography for visualization of signal Intensity distribution pattern within an unruptured cerebral aneurysm: preliminarily assessment with anterior communicating artery aneurysms

    International Nuclear Information System (INIS)

    Satoh, T.; Ekino, C.; Ohsako, C.

    2004-01-01

    The natural history of unruptured cerebral aneurysm is not known; also unknown is the potential growth and rupture in any individual aneurysm. The authors have developed transluminal color-coded three-dimensional magnetic resonance angiography (MRA) obtained by a time-of-flight sequence to investigate the interaction between the intra-aneurysmal signal intensity distribution patterns and configuration of unruptured cerebral aneurysms. Transluminal color-coded images were reconstructed from volume data of source magnetic resonance angiography by using a parallel volume-rendering algorithm with transluminal imaging technique. By selecting a numerical threshold range from a signal intensity opacity chart of the three-dimensional volume-rendering dataset several areas of signal intensity were depicted, assigned different colors, and visualized transparently through the walls of parent arteries and an aneurysm. Patterns of signal intensity distribution were analyzed with three operated cases of an unruptured anterior communicating artery aneurysm and compared with the actual configurations observed at microneurosurgery. A little difference in marginal features of an aneurysm was observed; however, transluminal color-coded images visualized the complex signal intensity distribution within an aneurysm in conjunction with aneurysmal geometry. Transluminal color-coded three-dimensional magnetic resonance angiography can thus provide numerical analysis of the interaction between spatial signal intensity distribution patterns and aneurysmal configurations and may offer an alternative and practical method to investigate the patient-specific natural history of individual unruptured cerebral aneurysms. (orig.)

  6. Application of dual volume reconstruction technique in embolization of intracranial aneurysms

    Directory of Open Access Journals (Sweden)

    Xiang-hai ZHANG

    2014-03-01

    Full Text Available Objective To explore the value of dual volume reconstruction technique in Guglielmi detachable coil (GDC embolization of intracranial aneurysms. Methods Three-dimensional imaging data of 20 patients received GDC embolization of intracranial aneurysms from Jun. 2012 to Apr. 2013 were analyzed for dual volume reconstruction. The value of application of dual volume reconstruction was evaluated by the detection rate of coils bolus, degree of aneurysm occlusion, the length of aneurysm sac and aneurysm neck before and after embolization, and the characteristics and clinical value of the reconstructed images. Results  A total of 20 coil boluses were detected by dual volume reconstruction images, and the detection rate was 100%. Among all of 20 patients, no visualization of contrast medium in the aneurysm was found in 13 patients, while contrast agent was found in the aneurysm sac in 3 patients and in the aneurysm neck in 4 patients. The length of aneurysm neck and sac was somewhat changed before and after embolization with no statistically significant difference (P>0.05. The dual volume reconstruction could reveal coil bolus, vessels, cranium and fusion images, and the aneurysms could be shown by different imaging modes according to the clinical requirement. Conclusion Dual volume reconstruction technique can display the location of coil bolus, degree of occlusion and aneurysm size, and evaluate the embolization effect by multifarious imaging modes, providing a great deal of information for the evaluation of GDC embolization of intracranial aneurysm. DOI: 10.11855/j.issn.0577-7402.2014.02.13

  7. Headache, cerebral aneurysms, and the use of triptans and ergot derivatives.

    Science.gov (United States)

    Baron, Eric P

    2015-05-01

    Uncertainty exists regarding the correlation between unruptured cerebral aneurysms and their role in headache etiology. It is also unclear whether surgical endovascular treatment may improve or worsen the headache, and if there are predictable factors for headache outcome such as pre-existing headache features, aneurysm characteristics, or other medical history. There is debate regarding safe treatment of migraine in patients with aneurysms, both before and after endovascular treatments. Particularly, there is hesitancy to use the triptans and ergot derivatives such as dihydroergotamine because of their vasoconstrictive effects and concern for adverse events related to the aneurysm such as aneurysmal instability and rupture. To review the literature regarding the anatomy, pathophysiology, and association between headache, untreated vs surgically treated aneurysms, and the use of triptans and ergot derivatives for migraine treatment in this setting. Associations between some headaches and aneurysms may exist. Some chronic headaches may respond to surgical aneurysm repair while others may worsen. These associations are undefined by current literature because of variable results, study methods, and limited data. Prospective studies are needed which incorporate pre- and post-procedure headache character and diagnosis, aneurysm characteristics, type of aneurysm repair, associated risk factors for worsening post-procedure headache, and ultimately combining all of these data to better predict headache outcome following surgical aneurysm treatment. Lastly, the caution and avoidance of triptan and ergot derivative use for migraine in the setting of aneurysm is not supported by the current evidence, and much of this concern may be excessive and unwarranted, although more evidence confirming safety is needed. © 2015 American Headache Society.

  8. Postoperative subdural hygroma and chronic subdural hematoma after unruptured aneurysm surgery: age, sex, and aneurysm location as independent risk factors.

    Science.gov (United States)

    Park, Jaechan; Cho, Jae-Hoon; Goh, Duck-Ho; Kang, Dong-Hun; Shin, Im Hee; Hamm, In-Suk

    2016-02-01

    This study investigated the incidence and risk factors for the postoperative occurrence of subdural complications, such as a subdural hygroma and resultant chronic subdural hematoma (CSDH), following surgical clipping of an unruptured aneurysm. The critical age affecting such occurrences and follow-up results were also examined. The case series included 364 consecutive patients who underwent aneurysm clipping via a pterional or superciliary keyhole approach for an unruptured saccular aneurysm in the anterior cerebral circulation between 2007 and 2013. The subdural hygromas were identified based on CT scans 6-9 weeks after surgery, and the volumes were measured using volumetry studies. Until their complete resolution, all the subdural hygromas were followed using CT scans every 1-2 months. Meanwhile, the CSDHs were classified as nonoperative or operative lesions that were treated by bur-hole drainage. The age and sex of the patients, aneurysm location, history of a subarachnoid hemorrhage (SAH), and surgical approach (pterional vs superciliary) were all analyzed regarding the postoperative occurrence of a subdural hygroma or CSDH. The follow-up results of the subdural complications were also investigated. Seventy patients (19.2%) developed a subdural hygroma or CSDH. The results of a multivariate analysis showed that advanced age (p = 0.003), male sex (p 60 years, which achieved a 70% sensitivity and 69% specificity with regard to predicting such subdural complications. The female patients ≤ 60 years of age showed a negligible incidence of subdural complications for all aneurysm groups, whereas the male patients > 60 years of age showed the highest incidence of subdural complications at 50%-100%, according to the aneurysm location. The subdural hygromas detected 6-9 weeks postoperatively showed different follow-up results, according to the severity. The subdural hygromas that converted to a CSDH were larger in volume than the subdural hygromas that resolved

  9. Should indications for WEB aneurysm treatment be enlarged? Report of a series of 20 patients with aneurysms in "atypical" locations for WEB treatment.

    Science.gov (United States)

    Pierot, L; Biondi, A; Narata, A-P; Mihalea, C; Januel, A-C; Metaxas, G; Bibi, R; Caroff, J; Soize, S; Cognard, C; Spelle, L; Herbreteau, D

    2017-06-01

    Flow disruption with the WEB device is an innovative technique for the endovascular treatment of wide neck bifurcation aneurysms. Good clinical practice trials have shown high safety of this treatment with good efficacy. Technical developments (single layer devices and smaller microcatheters) facilitate the treatment, potentially leading to enlargement of indications. This series is collecting aneurysms in "atypical" locations for WEB treatment and analyzing safety and efficacy of this treatment. In each participating center, patients with aneurysms treated with WEB were prospectively included in a local database. Patients treated for aneurysms in "atypical" locations were extracted. Patient and aneurysm characteristics, intraoperative complications, and anatomical results at the end of the procedure and at last follow-up were collected and analyzed. Five French neurointerventional centers included 20 patients with 20 aneurysms in "atypical" locations for WEB treatment treated with WEB. Aneurysm locations were ICA carotid-ophthalmic in 9 aneurysms (45.0%), ICA posterior communicating in 4 (20.0%), Pericallosal artery in 5 (25.0%), and basilar artery between P1 and superior cerebellar artery in 2 (10.0%). There were no complications (thromboembolic or intraoperative rupture) in this series. At follow-up (mean: 7.4 months), adequate occlusion was obtained in 100.0% of aneurysms. This series confirms that it is possible to enlarge indications of WEB treatment to "atypical" locations with good safety and efficacy. These data have to be confirmed in large prospective series. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. International Subarachnoid Aneurysm Trial 2009 : Endovascular Coiling of Ruptured Intracranial Aneurysms Has No Significant Advantage Over Neurosurgical Clipping

    NARCIS (Netherlands)

    Bakker, Nicolaas A.; Metzemaekers, Jan D. M.; Groen, Rob J. M.; Mooij, Jan Jakob A.; Van Dijk, J. Marc C.

    In the May 2009 issue of The Lancet Neurology, the 5-year follow-up results of the International Subarachnoid Aneurysm Trial (ISAT) were published. The authors concluded that, although the significant difference between coiling and neurosurgical clipping of ruptured intracranial aneurysms in terms

  11. Internal mammary artery aneurysm in Marfan syndrome: case report

    Energy Technology Data Exchange (ETDEWEB)

    Common, A A; Pressacco, J; Wilson, J K [Univ. of Toronto, Dept. of Mecial Imaging, Toronto, Ontario (Canada)

    1999-02-01

    Marfan syndrome has a pleomorphic phenotype. Those affected have abnormalities in the eyes and in the nervous, cardiovascular and musculoskeletal systems. Among these abnormalities are many reported aneurysms, involving the ascending, descending thoracic and abdominal aorta, the sinus of Valsalva, and the internal carotid artery. We report a left internal mammary artery (LIMA) aneurysm in a patient with Marfan syndrome and no other known predisposition to such an aneurysm. No other case of LIMA aneurysm in Marfan syndrome has, to our knowledge, been reported. (author)

  12. Internal mammary artery aneurysm in Marfan syndrome: case report

    International Nuclear Information System (INIS)

    Common, A.A.; Pressacco, J.; Wilson, J.K.

    1999-01-01

    Marfan syndrome has a pleomorphic phenotype. Those affected have abnormalities in the eyes and in the nervous, cardiovascular and musculoskeletal systems. Among these abnormalities are many reported aneurysms, involving the ascending, descending thoracic and abdominal aorta, the sinus of Valsalva, and the internal carotid artery. We report a left internal mammary artery (LIMA) aneurysm in a patient with Marfan syndrome and no other known predisposition to such an aneurysm. No other case of LIMA aneurysm in Marfan syndrome has, to our knowledge, been reported. (author)

  13. Epidemiological study of 183 patients with spontaneous rupture of cerebral aneurysm

    International Nuclear Information System (INIS)

    Antonova, D.; Tasheva, E.

    2015-01-01

    Cerebral vessels aneurysms represent a significant part of the cerebral vessels pathology. There is no extensive study on that in Bulgaria. We present a study of 183 patients with spontaneous rupture of cerebral aneurysm, diagnosed and treated in UMHATEM ‘Pirogov’, Sofia. We used clinical methods - data from subject history, analysis of the accompanying documentation, subject medical chart; imaging-diagnostics methods - CT, DSA and MRI; and statistical methods. A total of 183 patients with ruptured intracranial aneurysms were studied. 65% were females and 35% were men.The ration female/male is 1.86, The mean age of all patients is 53.1 ±10.1 years. The highest incidence of ruptured aneurysms is seen in the age group 50 to 59 years. Aneurysms of a. cerebri media and a. communicants anterior are the most frequent (63.4% in total); while the lest are those of a basilaris (4.9%). 88.5% of the aneurysms in the studied group are small, 9.8% are large and 1.6% are giant. Intracranial hematomas are seen in 13.1% of the patients with ruptured aneurysms. Most frequently hematomas are connected with a. cerebri media and a.communicants anterior (87.5% in total). Patients with multiple aneurysms are 11.5% in total, 85.7% of them with an aneurysm of a.cerebri media. The incidence of ruptured cerebral aneurysms is higher amongst female. Frequency in the fifth decade of life is the highest. Most often seen are the aneurysms of a. cerebri media and a. communicants anterior, and the least - those of a. basilaris. Intracranial hematomas most frequently are associated with ruptures of a. cerebri media and a. communicants anterior, in patients with multiple aneurysms the highest is the frequency of aneurysms of a. cerebri media. (authors)

  14. Characterizing saccular aortic arch aneurysms from the geometry-flow dynamics relationship.

    Science.gov (United States)

    Natsume, Kayoko; Shiiya, Norihiko; Takehara, Yasuo; Sugiyama, Masataka; Satoh, Hiroshi; Yamashita, Katsushi; Washiyama, Naoki

    2017-06-01

    Low wall shear stress (WSS) has been reported to be associated with accelerated atherosclerosis, aneurysm growth, or rupture. We evaluated the geometry of aortic arch aneurysms and their relationship with WSS by using the 4-dimensional flow magnetic resonance imaging to better characterize the saccular aneurysms. We analyzed the geometry in 100 patients using multiplanar reconstruction of computed tomography. We evaluated WSS and vortex flow using 4-dimensional flow magnetic resonance imaging in 16 of them, which were compared with 8 age-matched control subjects and eight healthy young volunteers. Eighty-two patients had a saccular aneurysm, and 18 had a fusiform aneurysm. External diameter/aneurysm length ratio and sac depth/neck width ratio of the fusiform aneurysms were constant at 0.76 ± 0.18 and 0.23 ± 0.09, whereas those of saccular aneurysms, especially those involving the outer curvature, were higher and more variable. Vortex flow was always present in the aneurysms, resulting in low WSS. When the sac depth/neck width ratio was less than 0.8, peak WSS correlated inversely with luminal diameter even in the saccular aneurysms. When this ratio exceeded 0.8, which was the case only with the saccular aneurysms, such correlation no longer existed and WSS was invariably low. Fusiform aneurysms elongate as they dilate, and WSS is lower as the diameter is larger. Saccular aneurysms dilate without proportionate elongation, and they, especially those occupying the inner curvature, have higher and variable sac depth/neck width ratio. When this ratio exceeds 0.8, WSS is low regardless of diameter, which may explain their malignant clinical behavior. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  15. Endovascular treatment of intracranial aneurysms using liquid polymer injection

    International Nuclear Information System (INIS)

    Liu Jianmin; Huang Qinghai; Xu Yi; Hong Bo

    2004-01-01

    Objective: To report our preliminary clinical experience in embolization of intracranial aneurysms with liquid polymer (Onyx). Methods: One case of posterior communicating artery aneurysm was treated with Onyx and microcoils, while the other one with multiple basilar aneurysms was treated by Onyx combined with stent-coiling technique. Results: All the aneurysms were totally occluded with patency of parent arteries. There was no procedure-related complication. The patients recovered well during clinical follow-up for 3 months. The angiographic follow-up in one patient showed the result was stable and Onyx was totally apart from the flow in parent artery. Conclusions: Short-term result suggests that endovascular treatment of intracranial aneurysms with liquid polymer is safe and effective, however more experience is needed. (authors)

  16. Double microcatheter technique for coiling intracranial aneurysms with unfavorable configurations

    Directory of Open Access Journals (Sweden)

    WANG Shu-yuan

    2013-03-01

    Full Text Available Background Although stent-assisted technique has been widely used clinically, it is still hard to perform coiling treatment for complicated intracranial aneurysms, including relatively wide-necked tiny aneurysms and lobulated wide-necked aneurys ms with important branch vessels arising from the neck. This study aims to investigate the feasibility and clinical results of endovascular treatment for intracranial aneurysms with unfavorable configurations by using double microcatheter technique. Methods Thirty-three cases with complicated aneurysms were treated by using double microcatheter technique from April 2008 to November 2012. The locations of these aneurysms were anterior communicating artery (7 cases, posterior communicating artery (14 cases, ophthalmic artery (3 cases, anterior choroidal artery (3 cases, origin of posterior inferior cerebellar artery (3 cases, bifurcation of middle cerebral artery (2 cases and top of basilar artery (1 case. The mean neck- to-body (width ratio was 0.80 ± 0.21 (0.53-1.33. The mean body (width-to-dome (height ratio was 1.12 ± 0.37 (0.55-2.12. The mean dome (height-to-neck ratio was 1.26 ± 0.41 (0.65-2.96. The diameter of neck ≥4 mm was seen in 7 aneurysms, neck≥height in 9 and neck ≥width in 8. Besides, there were 9 very small aneurysms (the maximum diameter≤3 mm and 13 aneurysms with important branch vessels arising from the neck. All of these aneurysms were treated with coiling by using double microcatheter technique. Results All aneurysms were successfully embolized. Immediate postembolization angiography showed no residual contrast filling in 19 aneurysms, and residual filling in 14. There were some small loops protruding from the neck without influencing the blood flow in 12 cases. At discharge, according to modified Rankin Scale (mRS, 30 patients with 0-1 scores presented excellent clinical outcomes and 3 patients with 2 scores had cognitive dysfunction and moderate disability due to vasospasm

  17. Noninvasive radiodiagnosis of aneurysms of the thoracic aorta

    International Nuclear Information System (INIS)

    Todua, F.I.; Petsko, A.P.; Arablinskij, A.V.; Kazanchyan, P.O.; Nikitaev, N.S.; Sultanaliev, T.A.

    1990-01-01

    The paper is concerned with analysis of the results of X-ray investigation of 45 patients with aneurysms of the distal part of the arch and descending part of the thoracic aorta. X-ray investigation helped to establish correct diagnosis of aneurysm of the aorta in 42 of 45 patients (93.3 %) on the basis of the detection of intense additional shadow formation in left pulmonary field, unseparable from the aortic shadow. The use of a new method of ultrasound diagnosis-duplex scanning-made it possible to establish the presence of aneurysm and to determine its sizes as well as to visualize the relation of the left subclavicular artery to aneurysm in 17 of 21 patients. CT-semiotics of aneurysms of the descending part of the thoracic aorta consisted in its dilatation over 3.5 cm, wall calcification, thrombosis of the cavity and change of the adjacent structures. Basing on the analysis of these signs correct diagnosis was established in 34 of 35 examinees (97.1 %)

  18. Renal aneurysm and arteriovenous fistula

    International Nuclear Information System (INIS)

    Savastano, S.; Feltrin, G.P.; Miotto, D.; Chiesura-Corona, M.; Padua Univ.

    1990-01-01

    Embolization was performed in six patients with renal artery aneurysms (n=2) and arteriovenous fistulas (AVF) (n=5). The aneurysms were observed in one patient with fibromuscular dysplasia and in another with Ehlers-Danlos syndrome. All the AVFs were intraparenchymal and secondary to iatrogenic trauma. Elective embolization was performed in five patients with good clinical results at follow-up between 1 and 9 years. Because of rupture of the aneurysm emergency embolization was attempted without success in the patient with Ehlers-Danlos syndrome, and nephrectomy was carried out. A postembolization syndrome complicated three procedures in which Gelfoam and polyvinyl alcohol were used; in two of these cases unexpected reflux of the particulate material occurred, resulting in limited undesired ablation of the ipsilateral renal parenchyma. Embolization is the most reliable and effective treatment for intrarenal vascular abnormalities since it minimizes the parenchymal damage. (orig.)

  19. Contrast settling in cerebral aneurysm angiography

    International Nuclear Information System (INIS)

    Wang Zhijie; Hoffmann, Kenneth R; Guterman, Lee R; Wang Zhou; Rudin, Stephen; Meng Hui

    2005-01-01

    During angiography, blood flow is visualized with a radiopaque contrast agent, which is denser than blood. In complex vasculature, such as cerebral saccular aneurysms, the density difference may produce an appreciable gravity effect, where the contrast material separates from blood and settles along the gravity direction. Although contrast settling has been occasionally reported before, the fluid mechanics behind it have not been explored. Furthermore, the severity of contrast settling in cerebral aneurysms varies significantly from case to case. Therefore, a better understanding of the physical principles behind this phenomenon is needed to evaluate contrast settling in clinical angiography. In this study, flow in two identical groups of sidewall aneurysm models with varying parent-vessel curvature was examined by angiography. Intravascular stents were deployed into one group of the models. To detect contrast settling, we used lateral view angiography. Time-intensity curves were analysed from the angiographic data, and a computational fluid dynamic analysis was conducted. Results showed that contrast settling was strongly related to the local flow dynamics. We used the Froude number, a ratio of flow inertia to gravity force, to characterize the significance of gravity force. An aneurysm with a larger vessel curvature experienced higher flow, which resulted in a larger Froude number and, thus, less gravitational settling. Addition of a stent reduced the aneurysmal flow, thereby increasing the contrast settling. We found that contrast settling resulted in an elevated washout tail in the time-intensity curve. However, this signature is not unique to contrast settling. To determine whether contrast settling is present, a lateral view should be obtained in addition to the anteroposterior (AP) view routinely used clinically so as to rule out contrast settling and hence to enable a valid time-intensity curve analysis of blood flow in the aneurysm

  20. RARE PRESENTATION OF SYMPTOMATIC BILATERAL PROXIMAL POPLITEAL ARTERY ANEURYSM

    Directory of Open Access Journals (Sweden)

    Thulasikumar Ganapathy

    2016-07-01

    Full Text Available True Popliteal artery aneurysm is the most common of all the peripheral artery aneurysms. We present a case of proximal popliteal artery aneurysm involvement both lower limb presented with gangrene in one lower limb and incapacitating claudication pain on the other lower limb. We have successfully repaired both sides aneurysm in the same sitting with Poly Tetra Fluro Ethylene (PTFE graft, as the patient also had multiple venous perforators’ involvement on both sides, which left us only with synthetic graft repair option rather than venous graft repair.

  1. Phantom pain after eye amputation

    DEFF Research Database (Denmark)

    Rasmussen, Marie L R; Prause, Jan U; Toft, Peter B

    2011-01-01

    Purpose: To characterize the quality of phantom pain, its intensity and frequency following eye amputation. Possible triggers and relievers of phantom pain are investigated. Methods: The hospital database was searched using surgery codes for patients who received ocular evisceration, enucleation...... was conducted by a trained interviewer. Results: Of the 173 patients in the study, 39 experienced phantom pain. The median age of patients who had experienced phantom pain was 45 years (range: 19–88). Follow-up time from eye amputation to participation in the investigation was 4 years (range: 2–46). Phantom...... scale, ranging from 0 to 100, was 36 (range: 1–89). One-third of the patients experienced phantom pain every day. Chilliness, windy weather and psychological stress/fatigue were the most commonly reported triggers for pain. Conclusions: Phantom pain after eye amputation is relatively common. The pain...

  2. Hybrid pregnant reference phantom series based on adult female ICRP reference phantom

    Science.gov (United States)

    Rafat-Motavalli, Laleh; Miri-Hakimabad, Hashem; Hoseinian-Azghadi, Elie

    2018-03-01

    This paper presents boundary representation (BREP) models of pregnant female and her fetus at the end of each trimester. The International Commission on Radiological Protection (ICRP) female reference voxel phantom was used as a base template in development process of the pregnant hybrid phantom series. The differences in shape and location of the displaced maternal organs caused by enlarging uterus were also taken into account. The CT and MR images of fetus specimens and pregnant patients of various ages were used to replace the maternal abdominal pelvic organs of template phantom and insert the fetus inside the gravid uterus. Each fetal model contains 21 different organs and tissues. The skeletal model of the fetus also includes age-dependent cartilaginous and ossified skeletal components. The replaced maternal organ models were converted to NURBS surfaces and then modified to conform to reference values of ICRP Publication 89. The particular feature of current series compared to the previously developed pregnant phantoms is being constructed upon the basis of ICRP reference phantom. The maternal replaced organ models are NURBS surfaces. With this great potential, they might have the feasibility of being converted to high quality polygon mesh phantoms.

  3. Assessment of long-term effects of aneurysms trapping and extracranial-intracranial bypass surgery in patients with complex cerebral aneurysms

    Directory of Open Access Journals (Sweden)

    MAO Zhi-qi

    2012-02-01

    Full Text Available Objective To study the long-term effects of extracranial-intracranial (EC-IC bypass and aneurysms trapping in patients with complex cerebral aneurysms. Methods Seventeen patients with complex aneurysms, who underwent EC-IC bypass and aneurysms trapping from 2008 to 2009, were followed up. Clinical records were reviewed, modified Rankin Scale (mRS was recorded at admission, discharging, and follow-up point, and activities of daily living (ADL scale (Barthel Index at admission and follow-up point. Results Seventeen patients (11 males and 6 females were followed up. At admission mRS scores were 1.06 ± 0.87, Barthel index 91.10 ± 10.30. Superficial temporal artery-middle cerebral artery (STA-MCA was performed in 8 cases, extracarotid artery-great saphenous vein-middle cerebral artery (ECA-GSV-MCA in 5 cases, extracarotid artery-radial artery-middle cerebral artery (ECA-RA-MCA in 3 cases, occipital artery-posterior inferior cerebellar artery (OA-PICA in 1 case. Patients were followed up for 19-39 months (mean 28.67 months. At follow-up point, 2 patients (11.76% died, operation-related mortality was 5.88% (1/17, operation-related morbidity 5.88% (1/17, mRS scores 1.07 ± 1.16, Barthel index 96.40 ± 10.30. Conclusion Patients with complex aneurysms who were impossible to be treated with surgical clipping or endovascular intervention could be cured with extracranial-intracranial bypass and aneurysms trapping, and good follow-up results were acquired.

  4. Aneurysm Complications

    Science.gov (United States)

    ... Susco Chair of Research North Shore University Hospital, Brain Aneurysm Center Chair of Research The Christopher C. Getch, MD Chair of Research Carol W. Harvey Memorial Chair of Research Kristen’s Legacy of Love Chair of Research TeamCindy Alcatraz Chair of Research ...

  5. 18F-FDG PET-CT uptake is a feature of both normal diameter and aneurysmal aortic wall and is not related to aneurysm size

    International Nuclear Information System (INIS)

    Barwick, Tara D.; Lyons, O.T.A.; Waltham, M.; Mikhaeel, N.G.; O'Doherty, M.J.

    2014-01-01

    Aortic metabolic activity is suggested to correlate with presence and progression of aneurysmal disease, but has been inadequately studied. This study investigates the 2-[ 18 F] fluoro-2-deoxy-D-glucose ( 18 F-FDG) uptake in a population of infra-renal abdominal aortic aneurysms (AAA), compared to a matched non-aneurysmal control group. The Positron Emission Tomography - Computed Tomography (PET/CT) database was searched for infra-renal AAA. Exclusion criteria were prior repair, vasculitis, and saccular/mycotic thoracic or thoraco-abdominal aneurysms. Matching of 159 non-aneurysmal ( max ) and target to background mediastinal blood pool ratio (TBR) were documented. Predictors of FDG uptake (age, sex, aortic diameter, hypertension, statin use, and diabetes) were assessed using univariate analysis. Follow-up questionnaires were sent to referring clinicians. Aneurysms (n = 151) and controls (n = 159) were matched (p > 0.05) for age, sex, diabetes, hypertension, smoking status, statin use, and indication for PET/CT. Median aneurysm diameter was 5.0 cm (range 3.2-10.4). On visual analysis there was no significant difference in the overall numbers with increased visual uptake 24 % (36/151) in the aneurysm group vs. 19 % (30/159) in the controls, p = ns. SUV max was slightly lower in the aneurysm group vs. controls (mean (2 SD) 1.75(0.79) vs. 1.84(0.58), p = 0.02). However there was no difference in TBR between the AAA group and controls (mean (2 SD) 1.03 (0.46) vs. 1.05(0.31), p = 0.36). During a median 18 (interquartile range 8-35) months' follow-up 20 were repaired and four were confirmed ruptured. The level of metabolic activity as assessed by 18 F-FDG PET/CT in infra-renal AAA does not correlate with aortic size and does not differ between aneurysms and matched controls. (orig.)

  6. History, Evolution, and Continuing Innovations of Intracranial Aneurysm Surgery.

    Science.gov (United States)

    Lai, Leon T; O'Neill, Anthea H

    2017-06-01

    Evolution in the surgical treatment of intracranial aneurysms is driven by the need to refine and innovate. From an early application of the Hunterian carotid ligation to modern-day sophisticated aneurysm clip designs, progress has been made through dedication and technical maturation of cerebrovascular neurosurgeons to overcome challenges in their practices. The global expansion of endovascular services has challenged the existence of aneurysm surgery, changing the complexity of the aneurysm case mix and volume that are referred for surgical repair. Concepts of how to best treat intracranial aneurysms have evolved over generations and will continue to do so with further technological innovations. As with the evolution of any type of surgery, innovations frequently arise from the criticism of current techniques. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Morphological and Hemodynamic Discriminators for Rupture Status in Posterior Communicating Artery Aneurysms.

    Science.gov (United States)

    Lv, Nan; Wang, Chi; Karmonik, Christof; Fang, Yibin; Xu, Jinyu; Yu, Ying; Cao, Wei; Liu, Jianmin; Huang, Qinghai

    2016-01-01

    The conflicting findings of previous morphological and hemodynamic studies on intracranial aneurysm rupture may be caused by the relatively small sample sizes and the variation in location of the patient-specific aneurysm models. We aimed to determine the discriminators for aneurysm rupture status by focusing on only posterior communicating artery (PCoA) aneurysms. In 129 PCoA aneurysms (85 ruptured, 44 unruptured), clinical, morphological and hemodynamic characteristics were compared between the ruptured and unruptured cases. Multivariate logistic regression analysis was performed to determine the discriminators for rupture status of PCoA aneurysms. While univariate analyses showed that the size of aneurysm dome, aspect ratio (AR), size ratio (SR), dome-to-neck ratio (DN), inflow angle (IA), normalized wall shear stress (NWSS) and percentage of low wall shear stress area (LSA) were significantly associated with PCoA aneurysm rupture status. With multivariate analyses, significance was only retained for higher IA (OR = 1.539, p PCoA aneurysms.

  8. Endovascular stenting for treatment of complex intracranial aneurysms: preliminary outcome

    International Nuclear Information System (INIS)

    Huang Qinghai; Liu Jianmin; Xu Yi; Hong Bo; Zhao Wenyuan; Zhou Xiaoping

    2004-01-01

    Objective: To summarize the technique and efficiency of combined endovascular stenting and Guglielmi detachable coils (GDC) packing for the treatment of intracranial wide-necked bifurcation aneurysms and recanalized aneurysms. Methods: The coronary stents were implanted across the necks of 5 intracranial wide-necked aneurysms (two at bifurcation of ICA, one at basilar artery and two recanalized PcoA aneurysms). The porous stents covered the ostia of vital side branches and perforating vessels in three cases. Microcatheters were introduced into the aneurysmal sac through the stent mesh and then followed by GDCs embolizing the aneurysms. Results: The stents were deployed in parent artery in all cases. Total occlusion was obtained in 4 cases, while more than 90% in one case with patency of the parent arteries and vital perforating arteries. Follow-up angiography performed in all patients 3-6 months later revealed no intrastent stenosis. All the patients recovered well except III nerve palsy in one patient which diminished 3 months later. Conclusion: Endovaseular therapy combined stent implantation and microcoil placement maybe a valid alteration for the treatment of wide-necked bifurcation aneurysms and recanalized aneurysms, which shows promise clinical application in the future. The ostia of vital side branches covered with stents showed no effect on hemodynamics. (authors)

  9. Reverse waffle cone technique in management of stent dislodgement into intracranial aneurysms.

    Science.gov (United States)

    Luo, Chao-Bao; Lai, Yen-Jun; Teng, Michael Mu-Huo; Chang, Feng-Chi; Lin, Chung-Jung; Guo, Wan-Yuo

    2013-09-01

    Stent-assisted coil embolization (SACE) is a common method to manage intracranial wide-neck aneurysm. Using this technique, a stent must be successfully deployed into the parent artery to cross the aneurysm neck. We describe the reverse waffle cone technique in management of intra-procedural stent dislodgement during SACE of internal carotid artery (ICA) wide-neck aneurysms. Two patients with unruptured wide-neck ICA aneurysms underwent SACE. Intra-procedural forward stent migration occurred during catheterization with proximal stent dislodgement and migration into the aneurysm sac. Navigation of a second stent to bridge the aneurysm neck failed in one patient because the second stent was impeded by the dislodged stent. Using the reverse waffle cone technique, a microcatheter was navigated into the aneurysm sacs. Coils were safely detached into each aneurysm sac without any device assistance. The two wide-neck aneurysms were successfully treated with preservation of flow to the internal carotid arteries. The complication of intra-procedural distal stent migration and dislodgement, with proximal stent prolapse into an aneurysm sac, may not result in a failure to coil the aneurysm. The reverse waffle cone technique provides an effective treatment in the management of this complication. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. A coil placement technique to treat intracranial aneurysm with incorporated artery

    Directory of Open Access Journals (Sweden)

    Chao-Bao Luo

    2018-03-01

    Conclusion: This technique is effective and safe in managing intracranial aneurysms with IAs. Although aneurysmal recurrence may occur in some aneurysms because of insufficient coiling, this technique is simpler to perform and requires less skill than other techniques. It can be an alternative option for treating some selected intracranial aneurysms with IAs.

  11. Multilevel segmentation of intracranial aneurysms in CT angiography images

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yan [Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California 94122 and University of Lyon, CREATIS, CNRS UMR 5220, INSERM U1206, UCB Lyon1, INSA Lyon, Lyon 69100 (France); Zhang, Yue, E-mail: y.zhang525@gmail.com [Veterans Affairs Medical Center, San Francisco, California 94121 and University of Lyon, CREATIS, CNRS UMR 5220, INSERM U1206, UCB Lyon1, INSA Lyon, Lyon 69100 (France); Navarro, Laurent [Ecole Nationale Superieure des Mines de Saint-Etienne, Saint-Etienne 42015 (France); Eker, Omer Faruk [CHU Montpellier, Neuroradiologie, Montpellier 34000 (France); Corredor Jerez, Ricardo A. [Ecole Polytechnique Federale de Lausanne, Lausanne 1015 (Switzerland); Chen, Yu; Zhu, Yuemin; Courbebaisse, Guy [University of Lyon, CREATIS, CNRS UMR 5220, INSERM U1206, UCB Lyon1, INSA Lyon, Lyon 69100 (France)

    2016-04-15

    Purpose: Segmentation of aneurysms plays an important role in interventional planning. Yet, the segmentation of both the lumen and the thrombus of an intracranial aneurysm in computed tomography angiography (CTA) remains a challenge. This paper proposes a multilevel segmentation methodology for efficiently segmenting intracranial aneurysms in CTA images. Methods: The proposed methodology first uses the lattice Boltzmann method (LBM) to extract the lumen part directly from the original image. Then, the LBM is applied again on an intermediate image whose lumen part is filled by the mean gray-level value outside the lumen, to yield an image region containing part of the aneurysm boundary. After that, an expanding disk is introduced to estimate the complete contour of the aneurysm. Finally, the contour detected is used as the initial contour of the level set with ellipse to refine the aneurysm. Results: The results obtained on 11 patients from different hospitals showed that the proposed segmentation was comparable with manual segmentation, and that quantitatively, the average segmentation matching factor (SMF) reached 86.99%, demonstrating good segmentation accuracy. Chan–Vese method, Sen’s model, and Luca’s model were used to compare the proposed method and their average SMF values were 39.98%, 40.76%, and 77.11%, respectively. Conclusions: The authors have presented a multilevel segmentation method based on the LBM and level set with ellipse for accurate segmentation of intracranial aneurysms. Compared to three existing methods, for all eleven patients, the proposed method can successfully segment the lumen with the highest SMF values for nine patients and second highest SMF values for the two. It also segments the entire aneurysm with the highest SMF values for ten patients and second highest SMF value for the one. This makes it potential for clinical assessment of the volume and aspect ratio of the intracranial aneurysms.

  12. Natural history of cerebral saccular aneurysms | Ojini | West African ...

    African Journals Online (AJOL)

    Aneurysms less than 5mm have a very low rupture rate while those greater than 10mm have a significant risk of subsequent rupture. There is no consensus on the influence of the other reported risk factors such as hypertension, cigarette smoking and aneurysm location, on aneurysmal rupture. Those who have suffered a ...

  13. Changes of incompletely embolized aneurysm with tungsten coils : an experimental study in dogs

    International Nuclear Information System (INIS)

    Yu, In Kyu; Han, Moon Hee; Kim, Sung Hyun; Won, Hyung Jin; Chang, Kee Hyun; Yeon, Kyung Mo; Choe, Ghee Young; Kim, Sam Soo

    1999-01-01

    To evaluate changes of residual aneurysms according to the size of aneurysmal neck and thrombogenicity of a tungsten coil after incomplete embolization of experimental lateral aneurysms. Eleven experimental lateral aneurysms with different aneurysmal neck size were created in the common carotid arteries of mongrel dogs. They were then divided into narrow-neck(n=3), wide-neck(n=6) and spontaneously thrombosed control(n=2) groups. After confirmation of aneurysmal patency, incomplete embolizations of varying degrees (about 30% to near total occlusion) were performed using 5mm-diameter tungsten coils. Angiography was performed immediately before and after, and one and six weeks after embolizations. The size of residual aneurysm was measured on each angiogram. After the last angiography embolized aneurysms were excised and examined under light and electron microscopes. On angiograms obtained 6 weeks after embolization, all residual narrow neck aneurysms were completely occluded, whereas in those with a wide-neck, therre was either no change (n=4) or a slight increase in size(n=2). On light microscopy, all narrow-neck aneurysms showed total organized fibrosis while all control aneurysms and half those with a wide neck showed unorganized thrombi. The embolized group showed a higher degree of organization in the aneurysmal cavity than did the control group. Neointima formation was seen in all embolized aneurysms, but no aneurysm showed foreign body reaction. On electron microscopy, uniform thickness of plasma coatings was noted on the surface of the tungsten coils. A wide-neck residual aneurysm may persist or increase in size, while one with a narrow-neck can be thrombosed after incomplete embolization with tungsten coils in a lateral aneurym. Careful consideration might be necessary in the embolization of wide-neck aneurysms. With plasma coatings on its surface and organized fibrosis, tungsten coil can be an useful for embolization of an aneurysm

  14. Surgical treatment of pararenal aortic aneurysms in the elderly.

    Science.gov (United States)

    Illuminati, G; D'Urso, A; Ceccanei, G; Caliò, F; Vietri, F

    2007-12-01

    Until fenestrated endografts will become the standard treatment of pararenal aortic aneurysms, open surgical repair will currently be employed for the repair of this condition. Suprarenal aortic control and larger surgical dissection represent additional technical requirements for the treatment of pararenal aneurysms compared to those of open infrarenal aortic aneurysms, which may be followed by an increased operative mortality and morbidity rate. As this may be especially true when dealing with pararenal aneurysms in an elderly patients' population, we decided to retrospectively review our results of open pararenal aortic aneurysm repair in elderly patients, in order to compare them with those reported in the literature. Twenty-one patients over 75 years of age were operated on for pararenal aortic aneurysms in a ten-year period. Exposure of the aorta was obtained by means of a retroperitoneal access, through a left flank incision on the eleventh rib. When dealing with interrenal aortic aneurysm the left renal artery was revascularized with a retrograde bypass arising from the aortic graft, proximally bevelled on the ostium of the right renal artery. Two patients died of acute intestinal ischemia, yielding a postoperative mortality of 9.5%. Nonfatal complications included 2 pleural effusions, a transitory rise in postoperative serum creatinine levels in 3 cases, and one retroperitoneal hematoma. Mean renal ischemia time was 23 min, whereas mean visceral ischemia time was 19 min. Mean inhospital stay was 11 days. Pararenal aortic aneurysms in the elderly can be surgically repaired with results that are similar to those obtained in younger patients.

  15. Morphological and Hemodynamic Discriminators for Rupture Status in Posterior Communicating Artery Aneurysms.

    Directory of Open Access Journals (Sweden)

    Nan Lv

    Full Text Available The conflicting findings of previous morphological and hemodynamic studies on intracranial aneurysm rupture may be caused by the relatively small sample sizes and the variation in location of the patient-specific aneurysm models. We aimed to determine the discriminators for aneurysm rupture status by focusing on only posterior communicating artery (PCoA aneurysms.In 129 PCoA aneurysms (85 ruptured, 44 unruptured, clinical, morphological and hemodynamic characteristics were compared between the ruptured and unruptured cases. Multivariate logistic regression analysis was performed to determine the discriminators for rupture status of PCoA aneurysms.While univariate analyses showed that the size of aneurysm dome, aspect ratio (AR, size ratio (SR, dome-to-neck ratio (DN, inflow angle (IA, normalized wall shear stress (NWSS and percentage of low wall shear stress area (LSA were significantly associated with PCoA aneurysm rupture status. With multivariate analyses, significance was only retained for higher IA (OR = 1.539, p < 0.001 and LSA (OR = 1.393, p = 0.041.Hemodynamics and morphology were related to rupture status of intracranial aneurysms. Higher IA and LSA were identified as discriminators for rupture status of PCoA aneurysms.

  16. A clinical feature and therapeutic strategy in pituitary adenomas associated with intracranial aneurysms

    International Nuclear Information System (INIS)

    Sasagawa, Yasuo; Tachibana, Osamu; Shiraga, Shunsuke; Takata, Hisasi; Akai, Takuya; Iizuka, Hideaki

    2012-01-01

    We studied the clinical feature and treatment strategy of pituitary adenomas associated with intracranial aneurysms. Among 102 pituitary adenoma patients (mean age: 54.8 years old) who received MR angiography and/or 3D-CT angiography,seven patients (6.9%) had intracranial aneurysms. The association of an aneurysm was more common in large size adenomas (p<0.05). According to the location of the aneurysms,five patients had these in the paraclinoid portion or cavernous portion of the internal carotid artery. Using MR images,we classified the aneurysms associated with pituitary adenomas as non-adjacent,adjacent,and intra-adenoma types. In non-adjacent types,an aneurysm is located apart from the adenoma,and has less chance of exposure during transsphenoidal surgery. In adjacent types,an aneurysm is located adjacent to the adenoma,and could be exposed during transsphenoidal surgery. In intra-adenoma types,an aneurysm is encased in the adenoma. In non-adjacent type aneurysms,a resection of the pituitary adenoma can be carried out before aneurysm treatment due to the low risk of rupture during surgery. In adjacent types,a tumor resection can precede aneurysm treatment in cases of low rupture risk aneurysms and untreatable aneurysms. In intra-adenoma types,adenoma resection should come after treatment of the aneurysms. Neurosurgeons should be careful about not only the presence of aneurysms in preoperative images during transsphenoidal surgery planning,but also their locations and proximity to adenomas. Such information may be crucial in deciding the order of treatment. (author)

  17. Epidemiology, genetic, natural history and clinical presentation of giant cerebral aneurysms.

    Science.gov (United States)

    Lonjon, M; Pennes, F; Sedat, J; Bataille, B

    2015-12-01

    Giant cerebral aneurysms represent 5% of intracranial aneurysms, and become symptomatic between 40 and 70 years with a female predominance. In the paediatric population, the giant aneurysm rate is higher than in the adult population. Classified as saccular, fusiform and serpentine, the natural history of giant cerebral aneurysms is characterized by thrombosis, growth and rupture. The pathogenesis of these giant aneurysms is influenced by a number of risk factors, including genetic variables. Genome-wide association studies have identified some chromosomes highlighting candidate genes. Although these giant aneurysms can occur at the same locations as their smaller counterparts, a predilection for the cavernous location has been observed. Giant aneurysms present with symptoms caused by a mass effect depending on their location or by rupture; ischemic manifestations rarely reveal the aneurysm. If the initial clinical descriptions have been back up by imagery, the clinical context with a pertinent analysis of the risk factors remain the cornerstone for the management decisions of these lesions. Five year cumulative rupture rates for patients with giant aneurysm were 40% for those located on the anterior part of circle of Willis and 50% for those on the posterior part. The poor outcome of untreated patients justifies the therapeutic risks. Copyright © 2015. Published by Elsevier Masson SAS.

  18. Aneurysm of the superficial femoral artery in an infant

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, M.; Komuro, H.; Matoba, K.; Kaneko, M. [Dept. of Paediatric Surgery, Inst. of Clinical Medicine, Univ. of Tsukuba, Ibaraki (Japan); Niitsu, M.; Itai, Y. [Dept. of Radiology, Inst. of Clinical Medicine, Univ. of Tsukuba, Ibaraki (Japan)

    2003-04-01

    An isolated arterial aneurysm in childhood is extremely rare. We report a 1-year-old girl with an aneurysm of the right superficial femoral artery, presenting as an asymptomatic mass of the thigh. The aneurysm involved the whole superficial femoral artery (9 cm in length), and surgical treatment would have required replacement of the affected artery. Conservative treatment was chosen, influenced by the patient's rapid growth at that time. Non-invasive, 3-D contrast-enhanced magnetic resonance angiography (MRA) was useful as an alternative to conventional angiography for detailed evaluation of the femoral arteries, including the aneurysm. (orig.)

  19. Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

    International Nuclear Information System (INIS)

    Kiarashi, Nooshin; Nolte, Adam C.; Sturgeon, Gregory M.; Ghate, Sujata V.; Segars, William P.; Nolte, Loren W.; Samei, Ehsan

    2015-01-01

    Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power

  20. Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

    Energy Technology Data Exchange (ETDEWEB)

    Kiarashi, Nooshin [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 and Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708 (United States); Nolte, Adam C. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Sturgeon, Gregory M.; Ghate, Sujata V. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 (United States); Segars, William P. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27708 (United States); Nolte, Loren W. [Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708 and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Samei, Ehsan [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 (United States); Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708 (United States); Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27708 (United States); Department of Physics, Duke University, Durham, North Carolina 27708 (United States); and others

    2015-07-15

    Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power

  1. Endovascular treatment of a true posterior communicating artery aneurysm.

    Science.gov (United States)

    Munarriz, Pablo M; Castaño-Leon, Ana M; Cepeda, Santiago; Campollo, Jorge; Alén, Jose F; Lagares, Alfonso

    2014-01-01

    Posterior communicating artery (PCoA) aneurysms are most commonly located at the junction of the internal carotid artery and the PCoA. "True" PCoA aneurysms, which originate from the PCoA itself, are rarely encountered. Most previously reported cases were treated surgically mainly before the endovascular option became available. A 53-year-old male presented with sudden onset of right hemiparesis and aphasia. Left middle cerebral artery stroke was diagnosed. Further studies revealed a 3 mm left PCoA aneurysm arising from the PCoA itself, attached to neither the internal carotid artery nor the posterior cerebral artery. Endovascular treatment was performed and the aneurysm was coiled completely. Technical advances in endovascular interventional technology have permitted an additional approach to these lesions. The possible endovascular significance of the treatment of true PCoA aneurysms is discussed.

  2. Mesenteric ischaemia after endovascular coiling of ruptured cerebral aneurysms.

    LENUS (Irish Health Repository)

    Kamel, M H

    2012-02-03

    Three patients were referred to a national neurosurgical centre following CT evidence of subarachnoid haemorrhage. The three patients, who were referred from different institutions within a seven week period, were Fisher grade 3 and WFNS Grade I at all times. Angiography showed a PCOM aneurysm in one case, a ruptured Basilar tip aneurysm and an unruptured ACOM aneurysm in another case, and an ACOM aneurysm in the third case. It was decided that the aneurysms were suitable for endovascular coiling. These patients had unremarkable intraoperative catheterizations and coiling but subsequently deteriorated post-operatively due to mesenteric ischaemia. Two patients required colectomy for mesenteric ischaemia, and the third arrested secondary to sepsis from bowel perforation. We discuss the various causes that may explain this association, and we alert the neurosurgical community for this complication which has not been reported before.

  3. Greater saphenous vein anomaly and aneurysm with subsequent pulmonary embolism

    OpenAIRE

    Ma, Truong; Kornbau, Craig

    2017-01-01

    Abstract Venous aneurysms often present as painful masses. They can present either in the deep or superficial venous system. Deep venous system aneurysms have a greater risk of thromboembolism. Though rare, there have been case reports of superficial aneurysms and thrombus causing significant morbidity such as pulmonary embolism. We present a case of an anomalous greater saphenous vein connection with an aneurysm and thrombus resulting in a pulmonary embolism. This is the only reported case o...

  4. Update on the prevention of death from ruptured abdominal aortic aneurysm.

    Science.gov (United States)

    Jacomelli, Jo; Summers, Lisa; Stevenson, Anne; Lees, Tim; Earnshaw, Jonothan J

    2017-09-01

    Objectives To monitor the early effect of a national population screening programme for abdominal aortic aneurysm in 65-year-old men. Setting The study used national statistics for death rates from abdominal aortic aneurysm (Office of National Statistics) and hospital admission data in England (Hospital Episode Statistics). Methods Information concerning deaths from abdominal aortic aneurysm (ruptured and non-ruptured) (1999-2014) and hospital admissions for ruptured abdominal aortic aneurysm (2000-2015) was examined. Results The absolute number of deaths from abdominal aortic aneurysm in men and women aged 65 and over has decreased by around 30% from 2001 to 2014, but as the population has increased, the relative reduction was 45.6% and 40.0%, respectively. Some 65% of all abdominal aortic aneurysm deaths are in men aged over 65; women aged 65 and over account for around 31%. Deaths from ruptured abdominal aortic aneurysm in men aged 60-74 (the screened group) appear to be declining at the same rate as in men aged 75 and over. The relative decline in admissions to hospital with ruptured abdominal aortic aneurysm may be greater in men and women aged 60-74 (which contains the screened group of men), than those older, giving the first possible evidence that abdominal aortic aneurysm screening is having an effect. Conclusion The death rate from abdominal aortic aneurysm is declining rapidly in England. There is the first evidence that screening may be contributing to this reduction.

  5. False iliac artery aneurysm following renal transplantation

    DEFF Research Database (Denmark)

    Levi, N; Sønksen, Jens Otto Reimers; Schroeder, T V

    1999-01-01

    We report a very rare case of a false iliac artery aneurysm following renal transplantation. The patient was a 51-year-old women who presented with a painful 10 x 10 cm pulsating mass in her left iliac fossa. The patient had received a second cadaveric renal transplantation 5 years previously....... The graft never functioned and transplant nephrectomy was performed 2 weeks later. A CT-scanning showed a 10 x 10 cm large aneurysm arising from the left external iliac artery. At operation a large false aneurysm was identified arising from the original transplant anastomotic site. Due to the extent...

  6. Internal Carotid Artery Blister-Like Aneurysm Caused by Aspergillus – Case Report

    International Nuclear Information System (INIS)

    Ogawa, Masaki; Sakurai, Keita; Kawaguchi, Takatsune; Naiki-Ito, Aya; Nakagawa, Motoo; Okita, Kenji; Matsukawa, Noriyuki; Shibamoto, Yuta

    2015-01-01

    Blister-like aneurysm of the supraclinoid internal carotid artery (ICA) is a well-documented cause of subarachnoid hemorrhage. Generally, this type of aneurysm is associated with various conditions such as hypertension, arteriosclerosis, and ICA dissection. Although Aspergillus is the most common organism causing intracranial fungal aneurysmal formation, there is no report of a blister-like aneurysm caused by Aspergillus infection. An 83-year-old man received corticosteroid pulse therapy followed by oral steroid therapy for an inflammatory pseudotumor of the clivus. Two months later, the patient was transported to an emergency department due to the diffuse subarachnoid hemorrhage, classified as Fisher group 4. Subsequent 3D computed tomography angiogram revealed a blister-like aneurysm at the superior wall of the left ICA. Six days later, the patient died of subarachnoid hemorrhage caused by the left ICA aneurysm rerupture. Autopsy revealed proliferation of Aspergillus hyphae in the wall of the aneurysm. Notably, that change was present more densely in the inner membrane than in the outer one. Thus, it was considered that Aspergillus hyphae caused infectious aneurysm formation in the left ICA via hematogenous seeding rather than direct invasion. The blister-like aneurysm is a rare but important cause of subarachnoid hemorrhage. This case report documents another cause of blister-like aneurysms, that is an infectious aneurysm associated with Aspergillus infection

  7. Unraveling the relationship between arterial flow and intra-aneurysmal hemodynamics.

    Science.gov (United States)

    Morales, Hernán G; Bonnefous, Odile

    2015-02-26

    Arterial flow rate affects intra-aneurysmal hemodynamics but it is not clear how their relationship is. This uncertainty hinders the comparison among studies, including clinical evaluations, like a pre- and post-treatment status, since arterial flow rates may differ at each time acquisition. The purposes of this work are as follows: (1) To study how intra-aneurysmal hemodynamics changes within the full physiological range of arterial flow rates. (2) To provide characteristic curves of intra-aneurysmal velocity, wall shear stress (WSS) and pressure as functions of the arterial flow rate. Fifteen image-based aneurysm models were studied using computational fluid dynamics (CFD) simulations. The full range of physiological arterial flow rates reported in the literature was covered by 11 pulsatile simulations. For each aneurysm, the spatiotemporal-averaged blood flow velocity, WSS and pressure were calculated. Spatiotemporal-averaged velocity inside the aneurysm linearly increases as a function of the mean arterial flow (minimum R(2)>0.963). Spatiotemporal-averaged WSS and pressure at the aneurysm wall can be represented by quadratic functions of the arterial flow rate (minimum R(2)>0.996). Quantitative characterizations of spatiotemporal-averaged velocity, WSS and pressure inside cerebral aneurysms can be obtained with respect to the arterial flow rate. These characteristic curves provide more information of the relationship between arterial flow and aneurysm hemodynamics since the full range of arterial flow rates is considered. Having these curves, it is possible to compare experimental studies and clinical evaluations when different flow conditions are used. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Visceral artery aneurysms and pseudoaneurysms. Retrospective analysis of interventional endovascular therapy of 43 aneurysms; Aneurysmen und Pseudoaneurysmen viszeraler Arterien. Retrospektive Analyse der interventionellen radiologischen Therapie von 43 Aneurysmen

    Energy Technology Data Exchange (ETDEWEB)

    Ruhnke, Hannes; Kroencke, Thomas J. [Klinikum Augsburg (Germany). Dept. of Diagnostic and Interventional Radiology and Neuroradiology

    2017-07-15

    To evaluate the results of interventional endovascular therapy of incidental and symptomatic visceral artery aneurysms in the elective and emergency situation. 43 aneurysms in 38 patients (19 female, 19 male, mean age: 57 ± 16 years [18-82]) were treated between 2011 and 2015. The characteristics of the aneurysms (true vs. false aneurysm, size, etiology, location, symptoms) were considered. Furthermore, we evaluated the intervention with respect to technical success, embolic/occlusive agents used, therapy-associated complications and post-interventional follow-up. 23 true aneurysms (maximum diameter: 22 ± 18 mm [11 - 67mm]) and 20 false aneurysms (maximum diameter: 9 ± 33 mm [3 - 150 mm]) were evaluated. The splenic (n = 14) and renal arteries (n = 18) were most frequently affected. The etiology was most commonly degenerative-atherosclerotic (47%) or iatrogenic post-operative (19%). 18/48 interventions were performed due to active bleeding. False aneurysms were associated significantly more often with active bleeding (63 vs. 25%, p = 0.012). 41/48 treatments were technically successful. Re-intervention was necessary 6 times. In 2 cases the endovascular approach did not succeed. There was a complication rate of 10%, whereby only 4 minor and 1 major complications occurred. No patient suffered from permanent sequelae. Aneurysms were primarily treated by using coils and if necessary additional embolic agents (liquid embolic agent or vascular plugs) (75%). In the follow-up period, reperfusion of treated aneurysms occurred at a rate of 7% (n = 3). Interventional endovascular therapy of visceral artery aneurysms is safe and effective in the elective treatment of incidental aneurysms as well as in significantly more frequent hemorrhaging false aneurysms in the emergency situation.

  9. Sex-related differences in patients treated surgically for aneurysmal subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Horiuchi, Tetsuyoshi; Tanaka, Yuichiro; Hongo, Kazuhiro

    2006-01-01

    Sex-related differences were examined in the clinical course of patients treated surgically for aneurysmal subarachnoid hemorrhage. Retrospective analyses were carried out to evaluate sex-related differences in aneurysm location, aneurysm size, preoperative neurological condition, preoperative computed tomography findings, and outcome among 2577 patients who underwent surgical repair of ruptured aneurysms. The internal carotid artery was most frequently affected in women and the anterior cerebral artery in men. Intracerebral or intraventricular hematoma was more common in men than in women. Some differences may be related to the location of the aneurysm. Sex-related differences were prominent in the 5th decade of life. These findings might be related to the menopause. Sex hormones may be involved in aneurysm formation. (author)

  10. Acute retroperitoneal bleeding due to inferior mesenteric artery aneurysm: Case report

    Directory of Open Access Journals (Sweden)

    Ferrón JA

    2010-06-01

    Full Text Available Abstract Background Visceral artery aneurysms (VAA, although uncommon, are increasingly being detected. We describe a case of spontaneous retroperitoneal hemorrhage from a ruptured IMA aneurysm associated with stenosis of the superior mesenteric artery (SMA and celiac trunk, successfully treated with surgery. Methods A 65-year-old man presented with abdominal pain and hypovolemic shock. Abdominal CT scan showed an aneurysm of the inferior mesenteric artery with retroperitoneal hematoma. In addition, an obstructive disease of the superior mesenteric artery and celiac axis was observed. Results Upon emergency laparotomy a ruptured inferior mesenteric artery aneurysm was detected. The aneurysm was excised and the artery reconstructed by end-to-end anastomosis. Conclusions This report discusses the etiology, presentation, diagnosis and case management of inferior mesenteric artery aneurysms.

  11. The Woven EndoBridge (WEB) as primary treatment for unruptured intracranial aneurysms.

    Science.gov (United States)

    van Rooij, Sanne Bt; van Rooij, Willem Jan; Peluso, Jo P; Sluzewski, Menno

    2018-01-01

    Purpose The intrasaccular flow disruptor Woven EndoBridge (WEB) device is developed for the treatment of wide-necked aneurysms without supportive devices. We used the WEB as primary treatment for unruptured aneurysms suitable for the device, regardless of neck size. Methods Between February 2015 and June 2017, 59 aneurysms in 51 patients were selectively treated with the WEB. There were 15 men and 36 women with a mean age of 59 years. Mean aneurysm size was 7.0 mm (range 3-22 mm). Of 59 aneurysms, 45 (76%) had a wide neck defined as ≥4 mm or dome-neck ratio ≤1.5. No stents or supporting balloons were used. Results Initial WEB position was judged good in all 59 unruptured aneurysms. One patient with a basilar tip aneurysm had a late thrombotic posterior cerebral artery occlusion by protrusion of the WEB over the artery. There were no procedural ruptures. Overall complication rate was 2.0% (1 of 51, 95% CI 0.01-11.3%). Imaging follow-up was available in 55 of 59 aneurysms (93%). At 3 months, 41 of 57 aneurysms (72%) were completely occluded, 12 (21%) had a neck remnant and 4 (7%) were incompletely occluded. Conclusion WEB treatment is safe and effective in selected unruptured aneurysms suitable for the device, regardless of neck size or location. There was no need for supportive devices. Three-quarters of all unruptured small aneurysms could be treated with the WEB. In our opinion, the WEB is a valuable alternative to coils, especially in wide-necked aneurysms.

  12. NMR-CT image and symbol phantoms

    International Nuclear Information System (INIS)

    Hongo, Syozo; Yamaguchi, Hiroshi; Takeshita, Hiroshi

    1990-01-01

    We have developed Japanese phantoms in two procedures. One is described as a mathematical expression. Another is 'symbol phantoms' in 3 dimensional picture-elements, each of which symbolize an organ name. The concept and the algorithm of the symbol phantom enables us to make a phantom for a individual in terms of all his transversal section images. We got 85 transversal section images of head and trunk parts, and those of 40 legs parts by using NMR-CT. We have made the individual phantom for computation of organ doses. The transversal section images were not so clear to identify all organs needed to dose estimation that we had to do hand-editing the shapes of organs with viewing a typical section images: we could not yet make symbol phantom in a automatic editing. Symbols were coded to be visual cords as ASCII characters. After we got the symbol phantom of the first stage, we can edit it easily using a word-processor. Symbol phantom could describe more freely the shape of organs than mathematical phantom. Symbol phantom has several advantages to be an individual phantom, but the only difficult point is how to determine its end-point as a reference man when we apply the method to build the reference man. (author)

  13. Posttraumatic True Aneurysm of the Axillary Artery Following Blunt Trauma

    Directory of Open Access Journals (Sweden)

    Tugrul Goncu

    2010-01-01

    Full Text Available The majority of the axillary artery aneurysm cases arise as pseudoaneurysms secondary to blunt or iatrogenic trauma. Isolated traumatic true axillary artery aneurysm is a relatively unusual disorder and generally occurs with repetitive blunt trauma. A 22-year-old female patient with distal axillary artery true aneurysm due to simple blunt axillothoracic trauma is presented. The aneurysm was excised with subpectoral-axillary approach and saphenous vein graft interposition was applied. Long-term follow-up with the patient was uneventful.

  14. Return of visual function after bilateral visual loss following flow diversion embolization of a giant ophthalmic aneurysm due to both reduction in mass effect and reduction in aneurysm pulsation.

    Science.gov (United States)

    Patel, Saharsh; Fargen, Kyle M; Peters, Keith; Krall, Peter; Samy, Hazem; Hoh, Brian L

    2015-01-01

    Large and giant paraclinoid aneurysms are challenging to treat by either surgical or endovascular means. Visual dysfunction secondary to optic nerve compression and its relationship with aneurysm size, pulsation and thrombosis is poorly understood. We present a patient with a giant paraclinoid aneurysm resulting in bilateral visual loss that worsened following placement of a Pipeline Embolization Device and adjunctive coiling. Visual worsening occurred in conjunction with aneurysm thrombosis, increase in maximal aneurysm diameter and new adjacent edema. Her visual function spontaneously improved in a delayed fashion to better than pre-procedure, in conjunction with reduced aneurysmal mass effect, size and pulsation artifact on MRI. This report documents detailed ophthalmologic and MRI evidence for the role of thrombosis, aneurysm mass effect and aneurysm pulsation as causative etiologies for both cranial nerve dysfunction and delayed resolution following flow diversion treatment of large cerebral aneurysms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. Aneurysmal bone cyst primary - about eight pediatric cases ...

    African Journals Online (AJOL)

    The aneurysmal bone cyst is a pseudotumoral lesion that can take several aspects. ... specific forms and atypical aneurysmal bone cyst which often pose a diagnostic challenge requiring radiological ... All patients had standard radiographs.

  16. Renovascular hypertension and intrarenal artery aneurysms in a preschool child

    International Nuclear Information System (INIS)

    Hobbs, David J.; Barletta, Gina-Marie; Bunchman, Timothy E.; Mowry, Jeanne A.

    2009-01-01

    Renovascular hypertension from renal artery aneurysmal formation is a rare complication of fibromuscular dysplasia. Few data exist to direct the management of intrarenal artery aneurysms in pediatric patients. We report the presentation, diagnosis and management of renovascular hypertension and intrarenal aneurysmal disease in a preschool child. (orig.)

  17. Renovascular hypertension and intrarenal artery aneurysms in a preschool child

    Energy Technology Data Exchange (ETDEWEB)

    Hobbs, David J.; Barletta, Gina-Marie; Bunchman, Timothy E. [Michigan State University College of Human Medicine, Grand Rapids, MI (United States); Helen DeVos Children' s Hospital, Pediatric Nephrology, Dialysis and Transplantation, Grand Rapids, MI (United States); Mowry, Jeanne A. [Oregon Health Sciences University, Pediatric Nephrology, Northwest Permanente, P.C. and Doernbecher Children' s Hospital, Portland, OR (United States)

    2009-09-15

    Renovascular hypertension from renal artery aneurysmal formation is a rare complication of fibromuscular dysplasia. Few data exist to direct the management of intrarenal artery aneurysms in pediatric patients. We report the presentation, diagnosis and management of renovascular hypertension and intrarenal aneurysmal disease in a preschool child. (orig.)

  18. Case of radiation induced aneurysm of extracranial carotid artery

    Energy Technology Data Exchange (ETDEWEB)

    Tashiro, Takashi; Ikota, Toshio; Yamashita, Kousuke; Kodama, Takao

    1988-08-01

    An unusual case of post-irradiation aneurysm of extracranial internal carotid artery is presented. A 70-year-old man, complaining of left cervical throbbing mass with focal pain, was admitted on February 8, 1985. It was noted, from his past history, that he had had surgery of the removal of cervical lymphnodes and that unknown dosage of irradiation had been added to the cervical region 30 years before. Left carotid angiography (on admission) demonstrated a giant aneurysm in the cervical portion of internal carotid artery. Right carotid angiography with compression of left carotid artery revealed good cross filling through anterior communicating artery. Computed tomography with contrast media showed a ring like enhanced mass, which was thought to suggest that a large part of the aneurysm was filled with intraluminal thrombosis. During 30 days of evaluation, the aneurysm grew larger and his cervical pain became untolerable. Operation, the resection of the aneurysm and the reconstruction (of circulation) with vein graft, was challenged on March 12. It was so difficult with meticulous work that the ligation of left common carotid artery was performed after all. Seven days after the operation, he suffered from the gastrointestinal bleeding, which was enough to lead him to hypovolemic shock. Thereafter, right hemiparesis and aphasia were brought about. Two months later, he died of pneumonia. On histological examination, it was demonstrated that the aneurysm communicated with the necrotic tissue and that the normal structure of the blood vessel was not observed in the aneurysmal wall and consisted of the collagenous fiber and granulated tissue. The aneurysm was interpreted as a false one.

  19. The mechanism of cerebral aneurysmal formation

    International Nuclear Information System (INIS)

    Yokoi, Toshihiro; Nozaki, Kazuhiko

    2010-01-01

    Cerebral aneurysm is a disease of poor prognosis and MR- and CT-angiographies are used for its diagnosis and in the preventive therapy of its rupture. Here discussed are formation and growth leading to rupture of the lesion for its advanced diagnosis and prevention of rupturing. Beginning from findings in animal experimentation in mice, rats and monkeys, discussed are pathology of the aneurysm, genes related with its formation, molecular biological approaches concerning apoptosis and NF-kB/TNF-α related inflammatory reactions, participation of sex hormone, clinical hemodynamic analyses based on 3D data from CT and MRI findings, and clinical studies. Authors consider that local hemodynamic stress loading is possibly related to cerebral aneurysm formation as it is yielded at the loading part of the vessel in human and in animal models. The aneurysm is possibly a result of remodeling disturbance by the load and subsequent excessive involution of the artery. In the process, probably included are the inflammation, apoptosis, degradation of extracellular matrix and functional impairment of endotherial cells. Future elucidation of molecular mechanisms underlying the aneurismal growth and rupture will bring about the improved treatment to prevent the disease by stabilizing the aneurismal wall. (T.T.)

  20. Tiny intracranial aneurysms: Endovascular treatment by coil embolisation or sole stent deployment

    International Nuclear Information System (INIS)

    Lu Jun; Liu Jiachun; Wang Lijun; Qi Peng; Wang Daming

    2012-01-01

    Purpose: Tiny intracranial aneurysms pose a significant therapeutic challenge for interventional neuroradiologists. The authors report their preliminary results of endovascular treatment of these aneurysms. Methods: Between January 2002 and December 2009, 52 tiny intracranial aneurysms (defined as ≤3 mm in maximum diameter) in 46 patients (22 men; mean age, 57.9 years) were treated by endosaccular coil embolisation or sole stent deployment in the parent artery. Of 52 aneurysms, 29 had ruptured and 23 remained unruptured. The initial angiographic results, procedural complications, and clinical outcomes were assessed at discharge. Imaging follow-up was performed with cerebral angiography. Results: One aneurysm coiling procedure failed because of unsuccessful micro-catheterization. Forty-three aneurysms were successfully coil embolized, of which complete occlusion was obtained in 14, subtotal occlusion in 18 and incomplete occlusion in 11. The other 8 aneurysms were treated by sole stent deployment in the parent artery. Procedural complications (2 intraprocedural ruptures and 3 thromboembolic events) occurred in 5 (9.6%) of 52 aneurysms, resulting in permanent morbidity in only 1 (2.2%, 1/46) patient. No rebleeding occurred during clinical follow-up (mean duration, 46.7 months). Of the 16 coiled aneurysms that receiving repetitive angiography, 6 initially completely and 3 subtotally occluded aneurysms remained unchanged, 4 initially subtotally and 3 incompletely occluded aneurysms progressed to total occlusion. Five sole stent deployed aneurysms received angiographic follow-up (mean duration, 10.0 months), of which 3 remained unchanged, 1 became smaller and 1 progressed to total occlusion. Conclusion: Endovascular treatment of tiny intracranial aneurysms is technical feasible and relatively safe. Coil embolisation seems to be effective in preventing early recanalisation, whereas sole stenting technique needs further investigation to determine its effectiveness.

  1. The value of MDCT in diagnosis of splenic artery aneurysms

    International Nuclear Information System (INIS)

    Sun Cong; Liu Cheng; Wang Ximing; Wang Daoping

    2008-01-01

    Objective: To evaluate the clinical value of multiple detector computed tomography (MDCT) in the diagnosis and planning the treatment of splenic aneurysms. Methods: Eight cases with splenic artery aneurysms (SAA) were retrospectively reviewed. Sixty four-slice spiral CT scans were performed. Intravenous contrast material was injected at 4 ml/s, and arterial and venous phase images were obtained. Subsequently, arterial phase images were analyzed and made for CT angiography. The diagnosis was made by using axial and reconstructive images. All of the patients were also performed Doppler color echocardiography. Results: All patients showed splenic artery and splenic artery aneurysms clearly with CT arterial phase images. Among them, six patients had splenic artery aneurysms, one had giant splenic artery aneurysms (GSAA) and one had splenic artery pseudoaneurysms. Ultrasound examination only diagnosed six of them. Conclusion: MDCT is a noninvasive and valuable method in diagnosis of splenic artery aneurysms and has high value in determination of treatment plan

  2. The value of MDCT in diagnosis of splenic artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Sun Cong [Shandong University, Shandong Provincial Medical Imaging Institute, Road jing-wu No. 324, Jinan, Shandong 250021 (China)], E-mail: suncong03@163.com; Liu Cheng; Wang Ximing; Wang Daoping [Shandong University, Shandong Provincial Medical Imaging Institute, Road jing-wu No. 324, Jinan, Shandong 250021 (China)

    2008-03-15

    Objective: To evaluate the clinical value of multiple detector computed tomography (MDCT) in the diagnosis and planning the treatment of splenic aneurysms. Methods: Eight cases with splenic artery aneurysms (SAA) were retrospectively reviewed. Sixty four-slice spiral CT scans were performed. Intravenous contrast material was injected at 4 ml/s, and arterial and venous phase images were obtained. Subsequently, arterial phase images were analyzed and made for CT angiography. The diagnosis was made by using axial and reconstructive images. All of the patients were also performed Doppler color echocardiography. Results: All patients showed splenic artery and splenic artery aneurysms clearly with CT arterial phase images. Among them, six patients had splenic artery aneurysms, one had giant splenic artery aneurysms (GSAA) and one had splenic artery pseudoaneurysms. Ultrasound examination only diagnosed six of them. Conclusion: MDCT is a noninvasive and valuable method in diagnosis of splenic artery aneurysms and has high value in determination of treatment plan.

  3. Surgical approach to giant aneurysms of the anterior circulation.

    Science.gov (United States)

    Giombini, S; Solero, C L; Ferraresi, S; Melcarne, A; Broggi, G; Pluchino, F

    1988-01-01

    The surgical approach to cerebral giant aneurysms is still a source of great concern. We describe our experience with giant aneurysms of the anterior circulation and discuss the different surgical techniques adopted. During the period January 1972-December 1985, a total of 33 patients were operated upon at the Istituto Neurologico "C. Besta" of Milan for a giant aneurysm of the anterior circulation. Nineteen cases had suffered subarachnoid haemorrhage before admission; in 14 cases the hospitalization was due to evidence of mass effect on the surrounding neurovascular structures. All aneurysms were directly approached: in 24 cases the neck was occluded by a suitable clip, in 4 cases intramural thrombosis was attempted, in 3 cases the aneurysms were definitively trapped and in one case aneurysmorrhaphy was performed after resection of the sac. Operative mortality was 12%. Long-term follow-up shows good results whenever exclusion of the aneurysm from cerebral circulation had been achieved, either after removal of the sac or not; on the contrary, only fair or poor results were evident when other surgical techniques were adopted, either electively or out of necessity. The importance of intraoperative protection and monitoring of brain function is stressed.

  4. 18F-FDG PET-CT uptake is a feature of both normal diameter and aneurysmal aortic wall and is not related to aneurysm size

    Energy Technology Data Exchange (ETDEWEB)

    Barwick, Tara D. [Imperial College Healthcare NHS Trust, Charing Cross Hospital, Department of Radiology/Nuclear Medicine, London (United Kingdom); Hammersmith Hospital, Department of Surgery and Cancer, Imperial College London, London (United Kingdom); Lyons, O.T.A.; Waltham, M. [King' s College London, BHF Centre of Research Excellence and NIHR Biomedical Research Centre at King' s Health Partners, Academic Department of Surgery, London (United Kingdom); Mikhaeel, N.G. [Guy' s and St Thomas' Foundation NHS Trust, Department of Oncology, London (United Kingdom); O' Doherty, M.J. [King' s Health Partners, Clinical PET Centre, St Thomas' Hospital, London (United Kingdom)

    2014-12-15

    Aortic metabolic activity is suggested to correlate with presence and progression of aneurysmal disease, but has been inadequately studied. This study investigates the 2-[{sup 18}F] fluoro-2-deoxy-D-glucose ({sup 18}F-FDG) uptake in a population of infra-renal abdominal aortic aneurysms (AAA), compared to a matched non-aneurysmal control group. The Positron Emission Tomography - Computed Tomography (PET/CT) database was searched for infra-renal AAA. Exclusion criteria were prior repair, vasculitis, and saccular/mycotic thoracic or thoraco-abdominal aneurysms. Matching of 159 non-aneurysmal (<3 cm diameter) controls from the same population was assessed. Infra-renal aortic wall FDG uptake was assessed using visual analysis; maximum standardized uptake value (SUV{sub max}) and target to background mediastinal blood pool ratio (TBR) were documented. Predictors of FDG uptake (age, sex, aortic diameter, hypertension, statin use, and diabetes) were assessed using univariate analysis. Follow-up questionnaires were sent to referring clinicians. Aneurysms (n = 151) and controls (n = 159) were matched (p > 0.05) for age, sex, diabetes, hypertension, smoking status, statin use, and indication for PET/CT. Median aneurysm diameter was 5.0 cm (range 3.2-10.4). On visual analysis there was no significant difference in the overall numbers with increased visual uptake 24 % (36/151) in the aneurysm group vs. 19 % (30/159) in the controls, p = ns. SUV{sub max} was slightly lower in the aneurysm group vs. controls (mean (2 SD) 1.75(0.79) vs. 1.84(0.58), p = 0.02). However there was no difference in TBR between the AAA group and controls (mean (2 SD) 1.03 (0.46) vs. 1.05(0.31), p = 0.36). During a median 18 (interquartile range 8-35) months' follow-up 20 were repaired and four were confirmed ruptured. The level of metabolic activity as assessed by {sup 18}F-FDG PET/CT in infra-renal AAA does not correlate with aortic size and does not differ between aneurysms and matched controls

  5. Technical Considerations of Giant Right Coronary Artery Aneurysm Exclusion

    Directory of Open Access Journals (Sweden)

    James Barr

    2016-01-01

    Full Text Available Giant coronary artery aneurysms are rare clinical entities. We report the case of a 49-year-old man who presented with dyspnoea and exertional chest pain. Investigations confirmed an aneurysmal right coronary artery measuring 4 cm with a fistulous communication to the right atrium. Following right atriotomy, the fistula was oversewn and the aneurysmal right coronary artery ligated at its origin and at several points along its course. A saphenous vein graft was anastomosed to the posterior descending artery. Persistent ventricular fibrillation occurred upon chest closure, attributed to ischaemia following ligation of the aneurysmal coronary artery. Emergent resternotomy and internal defibrillation were successfully performed. The sternum was stented open to reduce right ventricular strain and closed the following day. The patient made an unremarkable recovery. We here address the technical challenges associated with surgical repair of right coronary aneurysms and the physiology and management of potential complications.

  6. Morphological and Hemodynamic Discriminators for Rupture Status in Posterior Communicating Artery Aneurysms

    OpenAIRE

    Lv, Nan; Wang, Chi; Karmonik, Christof; Fang, Yibin; Xu, Jinyu; Yu, Ying; Cao, Wei; Liu, Jianmin; Huang, Qinghai

    2016-01-01

    Background and Purpose The conflicting findings of previous morphological and hemodynamic studies on intracranial aneurysm rupture may be caused by the relatively small sample sizes and the variation in location of the patient-specific aneurysm models. We aimed to determine the discriminators for aneurysm rupture status by focusing on only posterior communicating artery (PCoA) aneurysms. Materials and Methods In 129 PCoA aneurysms (85 ruptured, 44 unruptured), clinical, morphological and hemo...

  7. Effect of electromagnetic radiation on the coils used in aneurysm embolization.

    Science.gov (United States)

    Lv, Xianli; Wu, Zhongxue; Li, Youxiang

    2014-06-01

    This study evaluated the effects of electromagnetic radiation in our daily lives on the coils used in aneurysm embolization. Faraday's electromagnetic induction principle was applied to analyze the effects of electromagnetic radiation on the coils used in aneurysm embolization. To induce a current of 0.5mA in less than 5 mm platinum coils required to stimulate peripheral nerves, the minimum magnetic field will be 0.86 μT. To induce a current of 0.5 mA in platinum coils by a hair dryer, the minimum aneurysm radius is 2.5 mm (5 mm aneurysm). To induce a current of 0.5 mA in platinum coils by a computer or TV, the minimum aneurysm radius is 8.6 mm (approximate 17 mm aneurysm). The minimum magnetic field is much larger than the flux densities produced by computer and TV, while the minimum aneurysm radius is much larger than most aneurysm sizes to levels produced by computer and TV. At present, the effects of electromagnetic radiation in our daily lives on intracranial coils do not produce a harmful reaction. Patients with coiled aneurysm are advised to avoid using hair dryers. This theory needs to be proved by further detailed complex investigations. Doctors should give patients additional instructions before the procedure, depending on this study.

  8. The Use of Flow Diverting Stents to Treat Para-Ophthalmic Aneurysms

    Directory of Open Access Journals (Sweden)

    Pervinder Bhogal

    2017-08-01

    Full Text Available Background and purposeFew publications have dealt exclusively with the use of flow diverter stents for the treatment of para-ophthalmic aneurysms. We sought to determine the efficacy of flow diverting stents (FDSs to treat aneurysms in this specific location.MethodsWe retrospectively reviewed our database of prospectively collected information for all patients treated with flow diversion for an unruptured saccular para-ophthalmic aneurysm between September 2009 and January 2016. The aneurysm fundus size, neck size, number and type of FDS, complications, and follow-up data were recorded.ResultsWe identified 74 patients that matched our inclusion criteria. Of these patients, 18 patients were male (24.3%. The average fundus size was 4.8 mm, 11 aneurysms had previous coil occlusions and 63 were treated solely with flow diversion. At an initial angiographic follow-up (mean avg. 3.2 months, 71.8% of the aneurysms were occluded, and at the last follow-up (mean avg. 31.8 months, 88.9% of aneurysms were occluded. One patient suffered permanent morbidity (1.36% secondary to interruption of the antiplatelet medication and another died (1.36% secondary to in-stent thrombosis that was also due to an interruption in the antiplatelet medication.ConclusionTreatment of saccular para-ophthalmic aneurysms with FDS is feasible and carries a high degree of technical success with low complication rates and excellent rates of aneurysm exclusion.

  9. Aneurysmal subarachnoid hemorrhage with concomitant posterior communicating artery fenestration.

    Science.gov (United States)

    Weiner, Gregory M; Grandhi, Ramesh; Zwagerman, Nathan T; Agarwal, Nitin; Friedlander, Robert M

    2015-02-01

    Fenestrations of the posterior communicating artery (PCoA) are extremely rare. Associated aneurysms have only been documented three times in the literature, and none associated with a subarachnoid hemorrhage. We describe a 52-year-old female who presented with a subarachnoid hemorrhage secondary to a ruptured saccular aneurysm at the proximal limb of a fenestrated right PCoA. The patient was also found to have bilateral middle cerebral artery (MCA) aneurysms. Surgical management included surmising the etiology of the subarachnoid hemorrhage with subsequent clipping of both the right PCoA and MCA aneurysm. The potential embryological mechanisms leading to a PCoA fenestration are discussed.

  10. True aneurysm of the proximal occipital artery: Case report.

    Science.gov (United States)

    Illuminati, Giulio; Cannistrà, Marco; Pizzardi, Giulia; Pasqua, Rocco; Frezzotti, Francesca; Calio', Francesco G

    2018-01-01

    True aneurysms of the proximal occipital artery are rare, may cause neurological symptoms due to compression of the hypoglossal nerve and their resection may be technically demanding. The case of an aneurysm of the proximal occipital artery causing discomfort and tongue deviation by compression on the hypoglossal nerve is reported. Postoperative course after resection was followed by complete regression of symptoms. Surgical resection, as standard treatment of aneurysms of the occipital artery, with the eventual technical adjunct of intubation by the nose is effective in durably relieving symptoms and preventing aneurysm-related complication. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Pitfalls in the use of spiral CT for identification of intracranial aneurysms

    International Nuclear Information System (INIS)

    Young, N.; Kingston, R.J.; Dorsch, N.W.C.

    1999-01-01

    We describe problems encountered in our first 136 patients, with 95 aneurysms, who underwent spiral CT for investigation of possible aneurysms involving the circle of Willis and adjacent major vessels, and who had surgical and/or angiographic confirmation. There were seven false-positive cases, of which the first three could be explained by operator inexperience. There were four false negatives, all small aneurysms; two were not seen because of operator error and two were hidden by an adjacent larger aneurysm. Clip artefacts prevented diagnostic studies in six of 21 postoperative studies. One aneurysm was outside the CT field of view, being on a pericallosal artery. One basilar artery tip aneurysm was excluded from the field of the CT study because of a planning error. Inspection of the axial source images is critical if the diagnosis of small or thrombosed aneurysms is to be made. Close attention to image acquisition and computer modelling is required to reduce errors in spiral CT angiography of intracranial aneurysms. (orig.)

  12. Construction of Chinese reference female phantom

    International Nuclear Information System (INIS)

    Sheng Yinxiangzi; Liu Lixing; Xia Xiaobin

    2013-01-01

    In this study, a Voxel-based Chinese Reference female Phantom (VCRP-woman) is developed from an individual female phantom which was based on high resolution cross-sectional color photographs. An in-house C ++ program was developed to adjust the phantom. Finally, a reference female phantom with have the same height, weighte and similar organs masses with the Chinese reference adult female data. The adjusted phantom is then imported to MCNPX to calculate the organs absorbed dose and effective dose conversion coefficients. Results are compared between VCRP-woman and the ICRP adult reference female phantom. (authors)

  13. Phantom Sensations, Supernumerary Phantom Limbs and Apotemnophilia: Three Body Representation Disorders.

    Science.gov (United States)

    Tatu, Laurent; Bogousslavsky, Julien

    2018-01-01

    Body representation disorders continue to be mysterious and involve the anatomical substrate that underlies the mental representation of the body. These disorders sit on the boundaries of neurological and psychiatric diseases. We present the main characteristics of 3 examples of body representation disorders: phantom sensations, supernumerary phantom limb, and apotemnophilia. The dysfunction of anatomical circuits that regulate body representation can sometimes have paradoxical features. In the case of phantom sensations, the patient feels the painful subjective sensation of the existence of the lost part of the body after amputation, surgery or trauma. In case of apotemnophilia, now named body integrity identity disorder, the subject wishes for the disappearance of the existing and normal limb, which can occasionally lead to self-amputation. More rarely, a brain-damaged patient with 4 existing limbs can report the existence of a supernumerary phantom limb. © 2018 S. Karger AG, Basel.

  14. CT findings of portal vein aneurysm

    International Nuclear Information System (INIS)

    Yang, Dal Mo; Chang, Mi Son; Yoon, Myung Hwan; Kim, Hak Soo; Kim, Hyung Sik; Chung, Hyo Sun; Chung, Jin Woo

    1999-01-01

    To describe the CT findings of portal vein aneurysm in eight patients. All patients included in this study (two men and six women) underwent CT examinations between October 1996 and June1998. Of these eight, three were suffering from hepatic disease and portal hypertension. We determined the location, shape, size, and characteristics of the lesions, and the presence or absence of portal vein anomaly. Seven patients had intrahepatic portal vein aneurysm (at the umbilical portion of the left portal vein in five patients, between the transverse and umbilical portion of the left portal vein in one, and at the bifurcation of the anterior and posterior branch of the right portal vein in one), while extrahepatic portal vein aneurysm, at the confluence of the superior mesenteric and splenic vein was found in only one. Lesions were cyst-shaped in seven cases and saccular in one, and showed well-circumscribed, markedly enhanced mass, which communicated with the portal vein and/or gives off major branches. Portal vein anomaly, in which the right anterior segmental portal vein originated from the umbilical portion of the left portal vein, was seen in three patients. In all three, intrahepatic portal vein aneurysm was present at the umbilical portion of the left portal vein, and in one, the umbilical protion of the left portal vein was located to the right of the Cantlic line. CT examination can help reveal portal vein aneurysm by detecting a well-circumscribed, markedly enhanced mass which communicates with the portal vein and/or gives off major branches

  15. Surgical clipping is still a good choice for the treatment of paraclinoid aneurysms

    Directory of Open Access Journals (Sweden)

    Felix Hendrik Pahl

    2016-04-01

    Full Text Available ABSTRACT Paraclinoid aneurysms are lesions located adjacent to the clinoid and ophthalmic segments of the internal carotid artery. In recent years, flow diverter stents have been introduced as a better endovascular technique for treatment of these aneurysms. Method From 2009 to 2014, a total of 43 paraclinoid aneurysms in 43 patients were surgically clipped. We retrospectively reviewed the records of these patients to analyze clinical outcomes. Results Twenty-six aneurysms (60.5% were ophthalmic artery aneurysms, while 17 were superior hypophyseal artery aneurysms (39.5%. The extradural approach to the clinoid process was used to clip these aneurysms. One hundred percent of aneurysms were clipped (complete exclusion in 100% on follow-up angiography. The length of follow-up ranged from 1 to 60 months (mean, 29.82 months. Conclusion Surgical clipping continues to be a good option for the treatment of paraclinoid aneurysms.

  16. 21. Phantom pain.

    NARCIS (Netherlands)

    Wolff, A.P.; Vanduynhoven, E.; Kleef, M. van; Huygen, F.; Pope, J.E.; Mekhail, N.

    2011-01-01

    Phantom pain is pain caused by elimination or interruption of sensory nerve impulses by destroying or injuring the sensory nerve fibers after amputation or deafferentation. The reported incidence of phantom limb pain after trauma, injury or peripheral vascular diseases is 60% to 80%. Over half the

  17. Coil embolization of mycotic pulmonary artery aneurysm: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeen Woo; Lee, Jae Kyo; Hwang, Mi Soo; Cho, Kil Ho [College of Medicine, Yeungnam University, Taegu (Korea, Republic of)

    2000-02-01

    Aneurysms of the pulmonary artery are rare, with mycotic aneurysms occurring most frequently. This latter type may also occur in association with a lung abscess or septicemia, particularly in drug addicts. As far as we are aware, the radiologic findings of mycotic aneurysm of the pulmanary artery have not been reported in Korea. We present the simple chest radiographs, as well as the CT and angiographic findings, of a case of aneurysm of the pulmonary artery which was successfully embolized using a coil. (author)

  18. Coil embolization of mycotic pulmonary artery aneurysm: a case report

    International Nuclear Information System (INIS)

    Kim, Jeen Woo; Lee, Jae Kyo; Hwang, Mi Soo; Cho, Kil Ho

    2000-01-01

    Aneurysms of the pulmonary artery are rare, with mycotic aneurysms occurring most frequently. This latter type may also occur in association with a lung abscess or septicemia, particularly in drug addicts. As far as we are aware, the radiologic findings of mycotic aneurysm of the pulmanary artery have not been reported in Korea. We present the simple chest radiographs, as well as the CT and angiographic findings, of a case of aneurysm of the pulmonary artery which was successfully embolized using a coil. (author)

  19. Paediatric dissecting posterior cerebral aneurysms: report of two cases and review of the literature

    International Nuclear Information System (INIS)

    Vilela, Pedro; Goulao, Augusto

    2006-01-01

    Intracranial aneurysms in the paediatric population are uncommon, accounting for 2% to 6% of all aneurysms, and spontaneous arterial dissection is rarely reported as the cause of aneurysms in children, especially in the posterior cerebral artery. Two cases of paediatric spontaneous posterior cerebral artery dissecting aneurysms are reported, one in a 33-month-old male child presenting with aneurysmal rupture and subarachnoid haemorrhage and the other in a 9-year-old boy with an unruptured aneurysm. The first child was successfully treated by endovascular parent vessel occlusion without neurological deficit and in the second a spontaneous thrombosis of the aneurysm and its parent artery occurred associated with hydrocephalus and a favourable outcome. Dissecting aneurysms are dynamic lesions with variable and unpredictable evolution and close follow-up and/or early treatment is warranted. Spontaneous arterial dissection is a rare, probably still under-recognized, cause of intracranial aneurysms that may be responsible for a significant number of aneurysms and spontaneous aneurysmal thromboses in children. (orig.)

  20. Paediatric dissecting posterior cerebral aneurysms: report of two cases and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Vilela, Pedro; Goulao, Augusto [Garcia de Orta Hospital, Neuroradiology Department, Almada (Portugal)

    2006-08-15

    Intracranial aneurysms in the paediatric population are uncommon, accounting for 2% to 6% of all aneurysms, and spontaneous arterial dissection is rarely reported as the cause of aneurysms in children, especially in the posterior cerebral artery. Two cases of paediatric spontaneous posterior cerebral artery dissecting aneurysms are reported, one in a 33-month-old male child presenting with aneurysmal rupture and subarachnoid haemorrhage and the other in a 9-year-old boy with an unruptured aneurysm. The first child was successfully treated by endovascular parent vessel occlusion without neurological deficit and in the second a spontaneous thrombosis of the aneurysm and its parent artery occurred associated with hydrocephalus and a favourable outcome. Dissecting aneurysms are dynamic lesions with variable and unpredictable evolution and close follow-up and/or early treatment is warranted. Spontaneous arterial dissection is a rare, probably still under-recognized, cause of intracranial aneurysms that may be responsible for a significant number of aneurysms and spontaneous aneurysmal thromboses in children. (orig.)

  1. Two Cases of True Uterine Artery Aneurysms Diagnosed during Pregnancy

    DEFF Research Database (Denmark)

    Schlütter, Jacob Mørup; Johansen, Gry; Helmig, Rikke Bek

    2016-01-01

    We report 2 cases of true uterine artery aneurysms diagnosed during pregnancy. Both cases presented with nonspecific symptoms such as urethral obstruction, minimal vaginal bleeding and lower abdominal pain in the 2nd trimester. Both aneurysms were diagnosed by color Doppler ultrasound. In the fir...... masses, vague bladder symptoms or radiating pelvic pain. The diagnosis is readily made by color Doppler imaging. Elective Caesarean section should be the preferred mode of delivery to avoid rupture of the aneurysm during labor.......We report 2 cases of true uterine artery aneurysms diagnosed during pregnancy. Both cases presented with nonspecific symptoms such as urethral obstruction, minimal vaginal bleeding and lower abdominal pain in the 2nd trimester. Both aneurysms were diagnosed by color Doppler ultrasound. In the first...

  2. Unruptured Brain Aneurysms

    Science.gov (United States)

    ... treated with either endovascular coiling or open surgical clipping. However, if the unruptured aneurysm is treated successfully, ... Medical Advisory Board Publications BAF Newsletters Annual Reports News Public Service Announcements Press Releases Blog Administrative Tax ...

  3. A refined method for creating saccular aneurysms in the rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Krings, Timo [Department of Neuroradiology, University Hospital of the University of Technology Aachen, Pauwelsstrase 30, 52057, Aachen (Germany); Department of Neurosurgery, University Hospital of the University of Technology Aachen, Pauwelsstrase 30, 52057, Aachen (Germany); Moeller-Hartmann, Walter; Meetz, Alexander; Dreeskamp, Heiko; Stein, Klaus-Peter; Thron, Armin [Department of Neuroradiology, University Hospital of the University of Technology Aachen, Pauwelsstrase 30, 52057, Aachen (Germany); Hans, Franz-Josef; Thiex, Ruth; Gilsbach, Joachim M. [Department of Neurosurgery, University Hospital of the University of Technology Aachen, Pauwelsstrase 30, 52057, Aachen (Germany); Brunn, Anna [Department of Neuropathology, University Hospital of the University of Technology Aachen, Pauwelsstrase 30, 52057, Aachen (Germany); Scherer, Kira [Department of Laboratory Animal Science, University Hospital of the University of Technology Aachen, Pauwelsstrase 30, 52057, Aachen (Germany)

    2003-07-01

    We describe a refined animal model of human intracerebral aneurysms for testing endovascular devices for interventional neuroradiological procedures. Saccular aneurysms resulting from a stump of the right common carotid artery (CCA) were created in 15 New Zealand White rabbits by intraluminal incubation of elastase that was applied to the CCA after distal ligation of the CCA and proximal occlusion of the vessel using a pliable balloon. Subsequently a microcatheter was advanced to a position cranial to the balloon and the elastase was infused under fluoroscopic guidance to avoid retrograde flow to the trachea via aberrant vessels. Contrast-enhanced (CE) MRA at 1.5 T and conventional digital subtraction angiography was performed to test for aneurysm size, morphology and neck anatomy. In all 15 animals aneurysms resulted from the stump of the right CCA, ranging in size from 2.0 to 9.9 mm (mean 6.3 mm) in craniocaudal direction, 1.0 to 5.5 mm (mean 3.8 mm) in mediolateral direction and 1.0 to 3.8 mm (mean 2.4 mm) in neck diameter. Aneurysm morphology could be adequately demonstrated using CE MRA. On histological evaluation a loss of the internal elastic lamina was noted. The described method represents an easy, reliable, and reproducible method of aneurysm creation in the rabbit in an area of high shear stress. These aneurysms can be used for testing new endovascular devices for embolization of intracranial aneurysms. (orig.)

  4. A refined method for creating saccular aneurysms in the rabbit

    International Nuclear Information System (INIS)

    Krings, Timo; Moeller-Hartmann, Walter; Meetz, Alexander; Dreeskamp, Heiko; Stein, Klaus-Peter; Thron, Armin; Hans, Franz-Josef; Thiex, Ruth; Gilsbach, Joachim M.; Brunn, Anna; Scherer, Kira

    2003-01-01

    We describe a refined animal model of human intracerebral aneurysms for testing endovascular devices for interventional neuroradiological procedures. Saccular aneurysms resulting from a stump of the right common carotid artery (CCA) were created in 15 New Zealand White rabbits by intraluminal incubation of elastase that was applied to the CCA after distal ligation of the CCA and proximal occlusion of the vessel using a pliable balloon. Subsequently a microcatheter was advanced to a position cranial to the balloon and the elastase was infused under fluoroscopic guidance to avoid retrograde flow to the trachea via aberrant vessels. Contrast-enhanced (CE) MRA at 1.5 T and conventional digital subtraction angiography was performed to test for aneurysm size, morphology and neck anatomy. In all 15 animals aneurysms resulted from the stump of the right CCA, ranging in size from 2.0 to 9.9 mm (mean 6.3 mm) in craniocaudal direction, 1.0 to 5.5 mm (mean 3.8 mm) in mediolateral direction and 1.0 to 3.8 mm (mean 2.4 mm) in neck diameter. Aneurysm morphology could be adequately demonstrated using CE MRA. On histological evaluation a loss of the internal elastic lamina was noted. The described method represents an easy, reliable, and reproducible method of aneurysm creation in the rabbit in an area of high shear stress. These aneurysms can be used for testing new endovascular devices for embolization of intracranial aneurysms. (orig.)

  5. Repair of left coronary artery aneurysm, recurrent ascending aortic aneurysm, and mitral valve prolapse 19 years after Bentall's procedure in a patient with Marfan syndrome.

    Science.gov (United States)

    Badmanaban, Balaji; Mallon, Peter; Campbell, Norman; Sarsam, Mazin A I

    2004-01-01

    A 45-year-old female with Marfan syndrome had a Bentall's procedure performed 19 years ago. She presented with a 4-year history of gradually worsening dyspnea and decreasing exercise tolerance. Investigations revealed severe mitral valve prolapse, a left main stem coronary artery (LMSCA) aneurysm, and a recurrent aneurysm of the ascending aorta. The mitral valve was replaced and the aortic aneurysmal sac and the LMSCA aneurysm were then repaired by a modified Bentall procedure. The patient made an uneventful recovery and was discharged home.

  6. Surgical repair of an aberrant splenic artery aneurysm: report of a case.

    Science.gov (United States)

    Illuminati, Giulio; LaMuraglia, Glenn; Nigri, Giuseppe; Vietri, Francesco

    2007-03-01

    Aneurysms of the splenic artery are the most common splanchnic aneurysms. Aneurysms of a splenic artery with an anomalous origin from the superior mesenteric artery are however rare, with eight previously reported cases. Their indications for treatment are superposable to those of aneurysms affecting an orthotopic artery. Methods of treatment of this condition include endovascular, minimally invasive techniques and surgical resection. We report one more case of aneurysm of an aberrant splenic artery, treated with surgical resection, and preservation of the spleen.

  7. Virtual reality cerebral aneurysm clipping simulation with real-time haptic feedback.

    Science.gov (United States)

    Alaraj, Ali; Luciano, Cristian J; Bailey, Daniel P; Elsenousi, Abdussalam; Roitberg, Ben Z; Bernardo, Antonio; Banerjee, P Pat; Charbel, Fady T

    2015-03-01

    With the decrease in the number of cerebral aneurysms treated surgically and the increase of complexity of those treated surgically, there is a need for simulation-based tools to teach future neurosurgeons the operative techniques of aneurysm clipping. To develop and evaluate the usefulness of a new haptic-based virtual reality simulator in the training of neurosurgical residents. A real-time sensory haptic feedback virtual reality aneurysm clipping simulator was developed using the ImmersiveTouch platform. A prototype middle cerebral artery aneurysm simulation was created from a computed tomographic angiogram. Aneurysm and vessel volume deformation and haptic feedback are provided in a 3-dimensional immersive virtual reality environment. Intraoperative aneurysm rupture was also simulated. Seventeen neurosurgery residents from 3 residency programs tested the simulator and provided feedback on its usefulness and resemblance to real aneurysm clipping surgery. Residents thought that the simulation would be useful in preparing for real-life surgery. About two-thirds of the residents thought that the 3-dimensional immersive anatomic details provided a close resemblance to real operative anatomy and accurate guidance for deciding surgical approaches. They thought the simulation was useful for preoperative surgical rehearsal and neurosurgical training. A third of the residents thought that the technology in its current form provided realistic haptic feedback for aneurysm surgery. Neurosurgical residents thought that the novel immersive VR simulator is helpful in their training, especially because they do not get a chance to perform aneurysm clippings until late in their residency programs.

  8. Neonatal Intracranial Aneurysm Rupture Treated by Endovascular Management: A Case Report

    Directory of Open Access Journals (Sweden)

    Yi-Pei Tai

    2010-08-01

    Full Text Available Pediatric intracranial aneurysm rupture is rare, and is traditionally managed by surgical clipping. To the best of our knowledge, endovascular embolization of aneurysms in neonates has not previously been reported in Taiwan. We report a 9-day-old boy with intracranial aneurysms who underwent endovascular embolization, representing the youngest reported case in Taiwan. The 9-day-old boy presented with non-specific symptoms of irritable crying, seizure and respiratory distress. Computed tomography disclosed intraventricular hemorrhage, subarachnoid hemorrhage and focal intracranial hemorrhage around the right cerebellum. Subsequent computed tomographic angiography showed two sequential fusiform aneurysms, measuring 3 mm, located in the right side posterior inferior cerebellar artery (PICA. The patient underwent endovascular embolization because of the high risk of aneurysm re-rupture and the impossibility of surgical clipping due to the fusiform nature of the aneurysms. A postembolization angiogram revealed complete obliteration of the right distal PICA and proximal aneurysm. The distal PICA aneurysm was revascularized from the collateral circulation, but demonstrated a slow and delayed filling pattern. The patient's condition remained stable over the following week, and he was discharged without anticonvulsant therapy. No significant developmental delay was noted at follow-up at when he was 3 months old. This case emphasizes the need for clinical practitioners to consider a diagnosis of intracranial hemorrhage in neonates with seizure and increased intracranial pressure. Neonatal intracranial aneurysms can be treated safely by endovascular treatment.

  9. Annular subvalvular left ventricular aneurysm in Bahia, Brazil.

    Science.gov (United States)

    Guimarães, A C; Filho, A S; Esteves, J P; Abreu, W N; Vinhaes, L A; de Almeida Souza, J A; Machado, A

    1976-10-01

    Two cases of left ventricular aneurysm, a 16-year-old black boy and a 23-year-old white girl, from Bahia, Brazil, are presented. In both patients there was enlargement of the cardiac silhouette and a prominent bulge of the left inferior border. On the right oblique view a ring of calcium at the ventricular opening of the aneurysms was visualized. A left ventriculogram showed a huge aneurysm in the first case and a bulge on the lateral wall of the left ventricle in the other. Cardiac catheterization showed a rise in left and right ventricular end-diastolic pressures and in the mean pulmonary artery pressure. In the first case the contour of the right ventricular pressure curve showed a restrictive pattern. The similarities of these aneurysms with the annular submitral type described in young black Africans are stressed.

  10. MULTIDETECTOR COMPUTED TOMOGRAPHY FOR IDENTIFICATION OF INSTABILITY OF AORTIC ANEURYSM WALL

    Directory of Open Access Journals (Sweden)

    M. V. Vishnyakova Jr.

    2015-01-01

    Full Text Available Background: Aortic aneurysm is characterized by high incidence, polymorphic clinical features and sudden onset of severe complications.Aim: To develop a standard multidetector computed tomography (MDCT protocol for aortic aneurysm examination and image analysis for detection the signs of aortic wall instability.Materials and methods: The data of 279 patients with aortic aneurysm who underwent MDCT examination during 2009–2014 was analyzed to identify aortic wall instability signs.Results: Complicated course of aortic aneurysm was observed in 100 cases (36%. The most common sign of aortic wall instability was aortic dissection. According to our results, a new definition of aortic aneurysm complications was elaborated. It included signs of aortic wall instability with incomplete and/or complete disruption of aortic wall layers. A scheme of the most common patterns of aortic wall abnormalities was proposed, allowing a radiologist to reach high accuracy in characterizing this pathology.Conclusion: A dedicated MDCT protocol for aortic aneurysm detection and image analysis can increase quality of radiologic assessment of aneurysm wall allowing to approach to the level of histological accuracy.

  11. A Case of Ruptured Splenic Artery Aneurysm in Pregnancy

    Directory of Open Access Journals (Sweden)

    Elizabeth K. Corey

    2014-01-01

    Full Text Available Background. Rupture of a splenic artery aneurysm is rare complication of pregnancy that is associated with a significant maternal and fetal mortality. Case. A multiparous female presented in the third trimester with hypotension, tachycardia, and altered mental status. A ruptured splenic artery aneurysm was discovered at the time of laparotomy and cesarean delivery. The patient made a full recovery following resection of the aneurysm. The neonate survived but suffered severe neurologic impairment. Conclusion. The diagnosis of ruptured splenic artery aneurysm should be considered in a pregnant woman presenting with signs of intra-abdominal hemorrhage. Early intervention by a multidisciplinary surgical team is key to preserving the life of the mother and fetus.

  12. Primary mycotic aneurysm of the common carotid artery: Case report

    International Nuclear Information System (INIS)

    Lukasiewicz, A.; Molski, S.; Jundzill, W.; Meder, G.; Lasek, W.

    2006-01-01

    Aneurysms of the common carotid artery are relatively rare. Mycotic aneurysms in such location occur even less frequently. Causative factors can be sepsis, recent surgery, or dental procedures. Immunosuppression may also be a burdening factor. The authors present the case of a 70-year-old male patient with primary mycotic carotid artery aneurysm. The patient was diagnosed with ultrasound and multidetector spiral computed tomography and treated operatively with a PTFE prosthesis. Culture-appropriate antibiotic therapy was administered during the perioperative period. The rarity of extracranial carotid artery aneurysms might cause diagnostic and treatment difficulties. Open surgery is the recommended method, although the endovascular approach is gaining more acceptance. The choice of treatment modality might be facilitated by a detailed morphologic description of the aneurysm and its surroundings. Available methods of imaging are described. (author)

  13. True posterior communicating artery aneurysms: are they more prone to rupture? A biomorphometric analysis.

    Science.gov (United States)

    He, Wenzhuan; Hauptman, Jason; Pasupuleti, Latha; Setton, Avi; Farrow, Maria G; Kasper, Lydia; Karimi, Reza; Gandhi, Chirag D; Catrambone, Jeffrey E; Prestigiacomo, Charles J

    2010-03-01

    Posterior communicating artery (PCoA) aneurysms can occur at the junction with the internal carotid artery, posterior cerebral artery (PCA), or the proximal PCoA itself. Hemodynamic stressors contribute to aneurysm formation and may be associated with parent vessel size and aneurysm location. This study evaluates the correlation of various biomorphometric characteristics in 2 of the aforementioned types of PCoA aneurysms. Patients with PCoA aneurysms were analyzed using CT angiography. Source images and reconstructions were used to determine which aneurysms originated purely from the PCoA and those that originated from the internal carotid artery/PCoA junction. Morphometric analysis was performed on the aneurysm, the precommunicating segment of the PCA (P(1)), the ambient segment of the PCA (P(2)), and both PCoA arteries and were correlated to clinical presentation. Parametric and nonparametric analyses were performed to test for significance. A total of 77 PCoA aneurysms were analyzed, and 10 were found to be true PCoA aneurysms (13.0%). The ipsilateral PCoA/P(1) ratio (1.77 +/- 0.44 vs 0.82 +/- 0.46, p = 0.0001) and ipsilateral P(2)/P(1) ratio (1.73 +/- 0.40 vs 1.22 +/- 0.41, p = 0.0003) were significantly larger in true PCoA aneurysms. Interestingly, aneurysm size was statistically larger in the junctional aneurysms (0.14 +/- 0.1 vs 0.072 +/- 0.04 cm(3), p = 0.03). The prevalence of ruptured aneurysms was similar in both groups (approximately 80%, p value not significant). These data suggest that true PCoA aneurysms have a larger PCoA relative to the ipsilateral P(1) segment. To the authors' knowledge, this represents the first such biomorphometric comparison of these different types of PCoA aneurysms. Although statistically smaller in size, true PCoA aneurysms also have a similar prevalence of presenting as a ruptured aneurysm, suggesting that they might be more prone to rupture than a junctional aneurysms of similar size. Further analysis will be required to

  14. Enhancing brain lesions after endovascular treatment of aneurysms

    DEFF Research Database (Denmark)

    Cruz, J P; Marotta, T; O'Kelly, C

    2014-01-01

    present 7 patients from 5 different institutions that developed MR imaging-enhancing brain lesions after endovascular therapy of aneurysms, detected after a median time of 63 days. The number of lesions ranged from 4-46 (median of 10.5), sized 2-20 mm, and were mostly in the same vascular territory used......Complications of endovascular therapy of aneurysms mainly include aneurysm rupture and thromboembolic events. The widespread use of MR imaging for follow-up of these patients revealed various nonvascular complications such as aseptic meningitis, hydrocephalus, and perianeurysmal brain edema. We...

  15. ''de novo'' aneurysms following endovascular procedures

    Energy Technology Data Exchange (ETDEWEB)

    Briganti, F.; Cirillo, S.; Caranci, F. [Department of Neurological Sciences, Services of Neuroradiology, ' ' Federico II' ' University, Naples (Italy); Esposito, F.; Maiuri, F. [Department of Neurological Sciences, Services of Neurosurgery, ' ' Federico II' ' University, Naples (Italy)

    2002-07-01

    Two personal cases of ''de novo'' aneurysms of the anterior communicating artery (ACoA) occurring 9 and 4 years, respectively, after endovascular carotid occlusion are described. A review of the 30 reported cases (including our own two) of ''de novo'' aneurysms after occlusion of the major cerebral vessels has shown some features, including a rather long time interval after the endovascular procedure of up to 20-25 years (average 9.6 years), a preferential ACoA (36.3%) and internal carotid artery-posterior communicating artery (ICA-PCoA) (33.3%) location of the ''de novo'' aneurysms, and a 10% rate of multiple aneurysms. These data are compared with those of the group of reported spontaneous ''de novo'' aneurysms after SAH or previous aneurysm clipping. We agree that the frequency of ''de novo'' aneurysms after major-vessel occlusion (two among ten procedures in our series, or 20%) is higher than commonly reported (0 to 11%). For this reason, we suggest that patients who have been submitted to endovascular major-vessel occlusion be followed up for up to 20-25 years after the procedure, using non-invasive imaging studies such as MR angiography and high-resolution CT angiography. On the other hand, periodic digital angiography has a questionable risk-benefit ratio; it may be used when a ''de novo'' aneurysm is detected or suspected on non-invasive studies. The progressive enlargement of the ACoA after carotid occlusion, as described in our case 1, must be considered a radiological finding of risk for ''de novo'' aneurysm formation. (orig.)

  16. Morphological and hemodynamic analysis of mirror posterior communicating artery aneurysms.

    Directory of Open Access Journals (Sweden)

    Jinyu Xu

    Full Text Available BACKGROUND AND PURPOSE: Hemodynamic factors are commonly believed to play an important role in the pathogenesis, progression, and rupture of cerebral aneurysms. In this study, we aimed to identify significant hemodynamic and morphological parameters that discriminate intracranial aneurysm rupture status using 3-dimensional-angiography and computational fluid dynamics technology. MATERIALS AND METHODS: 3D-DSA was performed in 8 patients with mirror posterior communicating artery aneurysms (Pcom-MANs. Each pair was divided into ruptured and unruptured groups. Five morphological and three hemodynamic parameters were evaluated for significance with respect to rupture. RESULTS: The normalized mean wall shear stress (WSS of the aneurysm sac in the ruptured group was significantly lower than that in the unruptured group (0.52±0.20 versus 0.81±0.21, P = .012. The percentage of the low WSS area in the ruptured group was higher than that in the unruptured group (4.11±4.66% versus 0.02±0.06%, P = .018. The AR was 1.04±0.21 in the ruptured group, which was significantly higher than 0.70±0.17 in the unruptured group (P = .012. By contrast, parameters that had no significant differences between the two groups were OSI (P = .674, aneurysm size (P = .327, size ratio (P = .779, vessel angle (P = 1.000 and aneurysm inclination angle (P = 1.000. CONCLUSIONS: Pcom-MANs may be a useful disease model to investigate possible causes of aneurysm rupture. The ruptured aneurysms manifested lower WSS, higher percentage of low WSS area, and higher AR, compared with the unruptured one. And hemodynamics is as important as morphology in discriminating aneurysm rupture status.

  17. Endovascular treatment of ruptured true posterior communicating artery aneurysms.

    Science.gov (United States)

    Yang, Yonglin; Su, Wandong; Meng, Qinghai

    2015-01-01

    Although true posterior communicating artery (PCoA) aneurysms are rare, they are of vital importance. We reviewed 9 patients with this fatal disease, who were treated with endovascular embolization, and discussed the meaning of endovascular embolization for the treatment of true PCoA aneurysms. From September 2006 to May 2012, 9 patients with digital substraction angiography (DSA) confirmed true PCoA aneurysms were treated with endovascular embolization. Patients were followed-up with a minimal duration of 17 months and assessed by Glasgow Outcome Scale (GOS) score. All the patients presented with spontaneous subarachnoid hemorrhage from the ruptured aneurysms. The ratio of males to females was 1:2, and the average age of onset was 59.9 (ranging from 52 to 72) years. The preoperative Hunt-Hess grade scores were I to III. All patients had recovered satisfactorily. No permanent neurological deficits were left. Currently, endovascular embolization can be recommended as the top choice for the treatment of most true PCoA aneurysms, due to its advanced technique, especially the application of the stent-assisted coiling technique, combined with its advantage of mininal invasiveness and quick recovery. However, the choice of treatment methods should be based on the clinical and anatomical characteristics of the aneurysm and the skillfulness of the surgeon.

  18. Arterial occlusion to treat basilar artery dissecting aneurysm

    NARCIS (Netherlands)

    Cui, Qing Ke; Liu, Wei Dong; Liu, Peng; Li, Xue Yuan; Zhang, Lian Qun; Ma, Long Jia; Ren, Yun Fei; Wu, Ya Ping; Wang, Zhi Gang

    2015-01-01

    Object: To explore the clinical feasibility of employing occlusion to treat basilar artery dissecting aneurysm. Methods: One patient, male and 46 years old, suffered transient numbness and weakness on the right limbs. Cerebral angiography indicated basilar artery dissecting aneurysm. The patient

  19. Giant intracranial aneurysm embolization with a yield stress fluid material: insights from CFD analysis.

    Science.gov (United States)

    Wang, Weixiong; Graziano, Francesca; Russo, Vittorio; Ulm, Arthur J; De Kee, Daniel; Khismatullin, Damir B

    2013-01-01

    The endovascular treatment of intracranial aneurysms remains a challenge, especially when the aneurysm is large in size and has irregular, non-spherical geometry. In this paper, we use computational fluid dynamics to simulate blood flow in a vertebro-basilar junction giant aneurysm for the following three cases: (1) an empty aneurysm, (2) an aneurysm filled with platinum coils, and (3) an aneurysm filled with a yield stress fluid material. In the computational model, blood and the coil-filled region are treated as a non-Newtonian fluid and an isotropic porous medium, respectively. The results show that yield stress fluids can be used for aneurysm embolization provided the yield stress value is 20 Pa or higher. Specifically, flow recirculation in the aneurysm and the size of the inflow jet impingement zone on the aneurysm wall are substantially reduced by yield stress fluid treatment. Overall, this study opens up the possibility of using yield stress fluids for effective embolization of large-volume intracranial aneurysms.

  20. The same sequence variant on 9p21 associates with myocardial infarction, abdominal aortic aneurysm and intracranial aneurysm

    DEFF Research Database (Denmark)

    Helgadottir, Anna; Thorleifsson, Gudmar; Magnusson, Kristinn P

    2008-01-01

    . Here we report that rs10757278-G is associated with, in addition to CAD, abdominal aortic aneurysm (AAA; odds ratio (OR) = 1.31, P = 1.2 x 10(-12)) and intracranial aneurysm (OR = 1.29, P = 2.5 x 10(-6)), but not with T2D. This variant is the first to be described that affects the risk of AAA...

  1. Importance of stent-graft design for aortic arch aneurysm repair

    Directory of Open Access Journals (Sweden)

    C Singh

    2017-02-01

    Full Text Available Aneurysm of the aorta is currently treated by open surgical repair or endovascular repair. However, when the aneurysm occurs in regions between the aortic arch and proximal descending aorta, it can be a complex pathology to treat due to its intricate geometry. When complex aortic aneurysms are treated with the conventional procedures, some of the patients present with significant post-operative complications and high mortality rate. Consequently, a clinically driven hybrid innovation known as the frozen elephant trunk procedure was introduced to treat complex aortic aneurysms. Although this procedure significantly reduces mortality rate and operating time, it is still associated with complications such as endoleaks, spinal cord ischemia, renal failure and stroke. Some of these complications are consequences of a mismatch in the biomechanical behaviour of the stent-graft device and the aorta. Research on complex aneurysm repair tended to focus more on the surgical procedure than the stent-graft design. Current stent-graft devices are suitable for straight vessels. However, when used to treat aortic aneurysm with complex geometry, these devices are ineffective in restoring the normal biological and biomechanical function of the aorta. A stent-graft device with mechanical properties that are comparable with the aorta and aortic arch could possibly lead to fewer post-operative complications, thus, better outcome for patients with complex aneurysm conditions. This review highlights the influence stent-graft design has on the biomechanical properties of the aorta which in turn can contribute to complications of complex aneurysm repair. Design attributes critical for minimising postoperative biomechanical mismatch are also discussed.

  2. Endovascular Management of Ruptured Pancreaticoduodenal Artery Aneurysms Associated with Celiac Axis Stenosis

    International Nuclear Information System (INIS)

    Suzuki, Kojiro; Tachi, Yasushi; Ito, Shinji; Maruyama, Kunihiro; Mori, Yoshine; Komada, Tomohiro; Matsushima, Masaya; Ota, Toyohiro; Naganawa, Shinji

    2008-01-01

    The purpose of this study was to assess the efficacy of transcatheter arterial embolization for ruptured pancreaticoduodenal artery (PDA) aneurysms associated with celiac axis stenosis (CS). Seven patients (four men and three women; mean age, 64; range, 43-84) were treated with transcatheter arterial embolization between 2002 and 2007. They were analyzed with regard to the clinical presentation, radiological finding, procedure, and outcome. All patients presented with sudden epigastric pain or abdominal discomfort. Contrast-enhanced CT showed a small aneurysm and retroperitoneal hematoma around the pancreatic head in all patients. The aneurysms ranged from 0.3 to 0.9 cm in size. In one patient, two aneurysms were detected. The aneurysms were located in the pancreaticoduodenal artery (n = 5) and the dorsal pancreatic artery (n = 3). Embolization was performed with microcoils in all aneurysms (n = 8). N-Butyl 2-cyanoacrylate (n = 1) and gelatine particle (n = 1) were also used. Complete occlusion was achieved in four patients. In the other three patients, a significantly reduced flow to the aneurysm remained at final angiography. However, these aneurysms were thrombosed on follow-up CT within 2 weeks. And there was no recurrence of the symptoms and bleeding during follow-up (mean, 28 months; range, 5-65 months) in all patients. In conclusion, transcatheter arterial embolization for PDA aneurysms associated with CS is effective. Significant reduction of the flow to the aneurysm at final angiography may be predictive of future thrombosis.

  3. Use of flow-diverting devices in fusiform vertebrobasilar giant aneurysms

    DEFF Research Database (Denmark)

    Ertl, L; Holtmannspötter, M; Patzig, M

    2014-01-01

    BACKGROUND AND PURPOSE: Fusiform vertebrobasilar giant aneurysms are a rare (... and imaging follow-up. In this article, we present our experience with the treatment of fusiform vertebrobasilar giant aneurysms by flow diverting stents. We aim to stimulate a discussion of the best management paradigm for this challenging aneurysm subtype. MATERIALS AND METHODS: We retrospectively...... identified 6 patients with fusiform vertebrobasilar giant aneurysms who had been treated with flow-diverting stents between October 2009 and March 2012 in our center. The available data were re-evaluated. The modified Rankin Scale score was assessed before intervention, during the stay in hospital...

  4. Virtual reality system for diagnosis and therapeutic planning of cerebral aneurysms.

    Science.gov (United States)

    Mo, Da-peng; Bao, Sheng-de; Li, Liang; Yi, Zhi-qiang; Zhang, Jia-yong; Zhang, Yang

    2010-08-01

    The virtual reality (VR) system can provide the neurosurgeon to intuitively interact with and manipulate the three dimensional (3-D) image similarly to manipulate a real object. It was seldom reported that the system was used in diagnosis and treatment of cerebral aneurysms. This study aimed to investigate the application of VR system in diagnosis and therapeutic planning of cerebral aneurysms. A total of 24 cases of cerebral aneurysms were enrolled in this study from 2006 to 2008, which diagnosed by 3-D digital subtraction angiography (3D-DSA) or VR-based computed tomography angiographies (CTA). The VR system and 3D-DSA system were used to observe and measure aneurysms and the adjacent vessels. The data of observation and measurements were compared between VR image and 3D-DSA image. All the patients underwent surgical plan and simulated neurosurgical procedures in the VR system. There were 28 aneurysms detected in VR system and 3D-DSA system. The VR system generated clear and vivid 3-D virtual images which clearly displayed the location and size of the aneurysms and their precise anatomical spatial relations to the parent arteries and skull. The location, size and shape of the aneurysms and their anatomical relationship with the adjacent vessels were similar between 3-D virtual image and 3D-DSA, but the spatial relationship between aneurysms and skull only been displayed by VR system. This VR system also could simulate simple surgical procedures and surgical environments. The VR system can provide a highly effective way to provide precise imaging details as same as 3D-DSA system and assist the diagnosis of cerebral aneurysms with virtual 3-D data based on CTA. It significantly enhances the chosen therapeutic strategy of cerebral aneurysms.

  5. Renal arterial aneurysm--an incidental finding at autopsy.

    Directory of Open Access Journals (Sweden)

    Vaideeswar P

    1998-01-01

    Full Text Available Herein we describe a rare case of saccular renal artery aneurysm seen as an incidental autopsy finding in an elderly, hypertensive female. The aneurysm was seen as a small exophytic mass with calcified wall and lumen occluded by recanalized thrombus.

  6. Hepatic artery aneurysm repair: a case report

    Directory of Open Access Journals (Sweden)

    Jaunoo SS

    2009-01-01

    Full Text Available Abstract Introduction Hepatic artery aneurysms remain a clinically significant entity. Their incidence continues to rise slowly and mortality from spontaneous rupture is high. Repair is recommended in those aneurysms greater than 2 cm in diameter. It is not surprising that vascular comorbidities, such as ischaemic heart disease, are common in surgical patients, particularly those with arterial aneurysms such as these. The decision of when to operate on patients who require urgent surgery despite having recently suffered an acute coronary syndrome remains somewhat of a grey and controversial area. We discuss the role of delayed surgery and postoperative followup of this vascular problem. Case presentation A 58-year-old man was admitted with a 5.5 cm hepatic artery aneurysm. The aneurysm was asymptomatic and was an incidental finding as a result of an abdominal computed tomography scan to investigate an episode of haemoptysis (Figure 1. Three weeks prior to admission, the patient had suffered a large inferior myocardial infarction and was treated by thrombolysis and primary coronary angioplasty. Angiographic assessment revealed a large aneurysm of the common hepatic artery involving the origins of the hepatic, gastroduodenal, left and right gastric arteries and the splenic artery (Figures 2 and 3. Endovascular treatment was not considered feasible and immediate surgery was too high-risk in the early post-infarction period. Therefore, surgery was delayed for 3 months when aneurysm repair with reconstruction of the hepatic artery was successfully performed. Graft patency was confirmed with the aid of an abdominal arterial duplex. Plasma levels of conventional liver function enzymes and of alpha-glutathione-S-transferase were within normal limits. This was used to assess the extent of any hepatocellular damage perioperatively. The patient made a good recovery and was well at his routine outpatient check-ups. Conclusion There is no significant

  7. Outcome of emergency endovascular treatment of large internal iliac artery aneurysms with guidewires

    International Nuclear Information System (INIS)

    Cambj-Sapunar, Liana; Maskovic, Josip; Brkljacic, Boris; Radonic, Vedran; Dragicevic, Dragan; Ajduk, Marko

    2010-01-01

    Purpose: Guidewires have been reported as a useful occlusion material for large aneurysms of different locations with good short-term results. In this study we retrospectively evaluate long-term results of emergency embolization technique with guidewires in symptomatic internal iliac artery aneurysm (IIAA) impending rupture. Patients and methods: In four patients presented with acute abdominal pain, multidetector computed tomography revealed unstable, 7-14 cm large, IIAAs. Two patients were treated with coil embolization of distal branches followed by occlusion of aneurysmal sac with guidewires. In two patients embolization of aneurysmal sac alone was performed. Results: In three patients complete or near complete occlusion of the aneurysmal sac was achieved and abdominal pain ceased within hours. Two patients treated with embolization of distal iliac artery branches and aneurysmal sac developed claudication that lasted up to 1 year. Their aneurysms remained thrombosed and they were without symptoms until they died 31 and 56 months later of causes unrelated to IIAA. Two patients treated with embolization of the aneurysm alone were free of ischemic symptoms. Because of incomplete embolization of the sac in one patient open surgery treatment in a non-emergency setting was performed. Complete filling of aneurysmal sac was achieved in other patient but 2 years later his aneurysm re-opened and required open surgery treatment. Conclusion: Embolization of aneurysmal sac of large IIAA with guidewires may be effective for immediate treatment of impending rupture. Long-term results were better when embolization of the aneurysmal sac was combined with embolization of distal IIA branches.

  8. Virtual Reality Cerebral Aneurysm Clipping Simulation With Real-time Haptic Feedback

    Science.gov (United States)

    Alaraj, Ali; Luciano, Cristian J.; Bailey, Daniel P.; Elsenousi, Abdussalam; Roitberg, Ben Z.; Bernardo, Antonio; Banerjee, P. Pat; Charbel, Fady T.

    2014-01-01

    Background With the decrease in the number of cerebral aneurysms treated surgically and the increase of complexity of those treated surgically, there is a need for simulation-based tools to teach future neurosurgeons the operative techniques of aneurysm clipping. Objective To develop and evaluate the usefulness of a new haptic-based virtual reality (VR) simulator in the training of neurosurgical residents. Methods A real-time sensory haptic feedback virtual reality aneurysm clipping simulator was developed using the Immersive Touch platform. A prototype middle cerebral artery aneurysm simulation was created from a computed tomography angiogram. Aneurysm and vessel volume deformation and haptic feedback are provided in a 3-D immersive VR environment. Intraoperative aneurysm rupture was also simulated. Seventeen neurosurgery residents from three residency programs tested the simulator and provided feedback on its usefulness and resemblance to real aneurysm clipping surgery. Results Residents felt that the simulation would be useful in preparing for real-life surgery. About two thirds of the residents felt that the 3-D immersive anatomical details provided a very close resemblance to real operative anatomy and accurate guidance for deciding surgical approaches. They believed the simulation is useful for preoperative surgical rehearsal and neurosurgical training. One third of the residents felt that the technology in its current form provided very realistic haptic feedback for aneurysm surgery. Conclusion Neurosurgical residents felt that the novel immersive VR simulator is helpful in their training especially since they do not get a chance to perform aneurysm clippings until very late in their residency programs. PMID:25599200

  9. Left ventricular pseudoaneurysm versus aneurysm a diagnosis dilemma

    Directory of Open Access Journals (Sweden)

    Samarjit Bisoyi

    2016-01-01

    Full Text Available Free wall rupture of the left ventricle (LV is a rare but life-threatening complication of acute myocardial infaction. Very rarely such rupture may be contained by the adhering pericardium creating a pseudoaneurysm. This condition warrants for an emergency surgery. Left ventricular aneurysm is the discrete thinning of the ventricular wall (<5 mm with akinetic or dyskinetic wall motion causing an out-pouching of the ventricle. Given the propensity for pseudoaneurysms to rupture leading to cardiac tamponade, shock, and death, compared with a more benign natural history for true aneurysms, accurate diagnosis of these conditions is important. True aneurysm, usually, calls for an elective surgery. Clinically differentiating the two conditions remains a challenge. We report the case of a patient with LV pseudoaneurysm, initially diagnosed as true aneurysm at our institution. We have attempted to review the existing literature and discussed the characteristic findings of each entity.

  10. Ruptured tuberculous false aneurysm of the abdominal aorta: a case report.

    Science.gov (United States)

    Mechchat, Alae; Lekehal, Brahim; Mesnaoui, Abbes; Ammar, Fannid; Bensaid, Younes

    2011-01-01

    Tuberculous false aneurysm of the aorta is rare and has an unpredictable complication of aneurysm rupture. We report a case of a 32-year old woman who was referred to the Department of Vascular Surgery, Avicenne Hospital for severe abdominal pain. Chest x-ray revealed miliary tuberculosis. Contrast enhanced computed tomography (CT) scan showed a false aortic aneurysm involving the juxtarenal aorta. Antituberculous treatment was started because of high presumption of tuberculosis. Five days later, the patient presented with symptoms of aneurysm rupture. She underwent an emergency a surgical resection of the aneurysm with repair of the aortic wall defect by a Dacron Silver patch. The histopathologic examination of the aortic wall showed features of tuberculosis.

  11. Neurofibromatosis Type 1: Transcatheter Arterial Embolization for Ruptured Occipital Arterial Aneurysms

    International Nuclear Information System (INIS)

    Kanematsu, Masayuki; Kato, Hiroki; Kondo, Hiroshi; Goshima, Satoshi; Tsuge, Yusuke; Kojima, Toshiaki; Watanabe, Haruo

    2011-01-01

    Two cases of ruptured aneurysms in the posterior cervical regions associated with type-1 neurofibromatosis treated by transcatheter embolization are reported. Patients presented with acute onset of swelling and pain in the affected areas. Emergently performed contrast-enhanced CT demonstrated aneurysms and large hematomas widespread in the posterior cervical regions. Angiography revealed aneurysms and extravasations of the occipital artery. Patients were successfully treated by percutaneous transcatheter arterial microcoil embolization. Transcatheter arterial embolization therapy was found to be an effective method for treating aneurysmal rupture in the posterior cervical regions occurring in association with type-1 neurofibromatosis. A literature review revealed that rupture of an occipital arterial aneurysm, in the setting of neurofibromatosis type 1, has not been reported previously.

  12. Comparison of CT angiography and digital subtraction angiography in the evaluation of intracranial aneurysmal neck

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Baik, Seung Kug; Shin, Mi Jeong; Choi, Han Yong

    2001-01-01

    To compare the usefulness of three-dimensional multislice CT angiography(CTA) and digital subtraction angiography (DSA) in the evaluation of intracranial aneurysmal neck. Nineteen patients with intracranial aneurysm (23 cases) underwent DSA and subsequent CTA. Using a multislice CT scanner and the SSD(shaded surface display) technique, clipping, cutting and the MPR technique, three-dimensional images were obtained. These were (a) external, (b) internal, from the direction of the parent artery, (c) internal, from the direction of the aneurysmal dome, and (d) an aneurysmal cutting image. The CTA findings were retrospectively compared with the DSA images. Twenty aneurysms were small and three were large. In eleven cases aneurysm neck was small, in nine it was wide, and in three it was relatively wide. For aneurysmal neck evaluation, CTA was superior to DSA in six of nine wide-neck aneurysms and all three large-sized wide-neck aneurysms. In small neck aneurysms 8 of 11 cases and in relatively wide neck all 3 cases showed similarly good images by both modalities. Of the 23 cases demonstrated by four different images, 14 cases showed the best image in internal image from parent artery direction and 6 cases showed similarly good image in both aneurysmal cutting image and internal image from parent artery direction. In the evaluation of wide neck aneurysms, 7 of 9 cases showed the best image at internal image from parent artery direction, compared with other three different images. In two cases of aneurysms, calcification was visible in the aneurysmal wall, so it was difficult to evaluate the aneurysmal neck. CTA was superior to DSA in the evaluating the intracranial aneurysmal neck. CTA maybe an additional available modality to evaluate the aneurysmal neck which is difficult to detect by the DSA. And the information of intracranial aneurysmal neck through CTA will be of value in surgical and endovascular treatment

  13. Mycotic aneurysms : radiological diagnosis and therapeutic alternatives

    International Nuclear Information System (INIS)

    Urbano, J.; Arjonilla, M. A.

    2002-01-01

    To review mycotic aneurysms, their radiological diagnosis and therapeutic alternatives. Five men and a woman between 69 and 84 years old were diagnosed during the last 4 years with mycotic aneurysms. Three were in the aorta, one in the thoracic and two in the abdominal region; one was affecting the left primitive iliac artery, another the left popliteal artery and, in the last case, the medial cerebral artery. Hemo cultures were done on all patients. The surgical specimen was cultivated in 4. CAT was done on 5 patients, angiography on another five and Doppler ultrasound scan on two. Five patients showed positive hemo cultures and in two the surgical specimen culture was positive. The findings of the CAT were decisive in being able to suspect that the lesions were mycotic in nature. Three patients had to undergo emergency, expiring either in surgery or in postoperative care. One case was treated by means of aortic endo prosthesis, and one year later the patient remains asymptomatic. The cerebral aneurysm was embolized with metal coils and the patient remains asymptomatic three years later. The popliteal aneurysm underwent surgical intervention using an established protocol with good results. CAT is decisive in the diagnosis of mycotic aneurysms. Once detected, they must be treated without delay as their natural evolution is one of rapid expansion and rupture. Angiographies help in planning the treatment. Radiological intervention plays an important role in the treatment. (Author) 13 refs

  14. True pancreaticoduodenal artery aneurysms: A decision analysis

    International Nuclear Information System (INIS)

    Takao, Hidemasa; Nojo, Takeshi; Ohtomo, Kuni

    2010-01-01

    Purpose: True pancreaticoduodenal artery aneurysms are rare. No definitive study evaluating the natural history of these lesions or their preferred method of treatment has been published. The purpose of this study was to evaluate the outcome of preventive treatment of unruptured pancreaticoduodenal artery aneurysms using a Markov model. Materials and methods: With the use of a Markov model, we performed a decision analysis to evaluate the outcome of preventive treatment of unruptured pancreaticoduodenal artery aneurysms. The risk of rupture and the mortality of preventive treatment are unknown. Therefore, we performed sensitivity analysis using these parameters. Effectiveness was measured in life expectancy. Results: For 80-year-old patients, preventive treatment was dominated by no treatment if mortality rates of preventive treatment were greater than 1.4%, greater than 2.6%, greater than 3.8%, and greater than 4.8% at annual rupture rates of 1%, 2%, 3%, and 4%, respectively. For 50-year-old patients, preventive treatment was dominated by no treatment if mortality rates of preventive treatment were greater than 3.3%, greater than 5.9%, greater than 8.0%, and greater than 9.7% at annual rupture rates of 1%, 2%, 3%, and 4%, respectively. Conclusion: The effectiveness of preventive treatment of unruptured pancreaticoduodenal artery aneurysms depends on the aneurysm rupture rate, mortality rate of preventive treatment, and patient age. Taking into account the effects of these parameters is important in making treatment decisions.

  15. Cartilage and bone neoformation in rabbit carotid bifurcation aneurysms after endovascular coil embolization

    Directory of Open Access Journals (Sweden)

    H Plenk

    2008-11-01

    Full Text Available Occurrence and histomorphology of cartilage and bone neoformations was retrospectively evaluated in rabbit experimental aneurysms after endovascular coil embolization. During product development, 115 carotid bifurcation aneurysms were treated with hydrogel-containing devices (HydroCoil®, n=77; HydroSoft®, n=28; prototype Hydrogel-only, n=10; MicroVentionTerumo, Aliso Viejo, CA. Additional 29 aneurysms were treated with standard (n=22 or with degradable polymer-covered (n=7 platinum coils. After 4 to 52 weeks, the retrieved aneurysms were methylmethacrylate embedded, and ground sections were surface-stained with Rapid Bone Stain and Giemsa solution. Cartilage and/or bone tissue was assessed by light microscopy; respective tissue areas in the aneurysms were determined by computerized histomorphometry. Cartilage neoformation was observed from 26 to 52 weeks. Single chondrocytes to hyaline or fibrous cartilage areas, occupying up to 29% of the aneurysm cavity, were found in 6 aneurysms, treated with HydroCoil (n=4, Hydrogel-only (n=1, and resorbable polymer (n=1 devices. Chondral ossification associated cartilage neoformation in 2 of these 4 HydroCoil-treated aneurysms. Membranous woven and lamellar bone ossicles were observed from 13 to 52 weeks in 7 aneurysms, treated with HydroCoil (n=3 and platinum coil (n=4 devices. Altogether, cartilage and/or bone neoformation was observed in 13 (9% of 144 rabbit bifurcation aneurysms treated with various embolic devices. Incidence was low until 26 weeks, but increased at 52 weeks in both, HydroCoil and standard platinum coil treated aneurysms. As the neoformations were predominantly located in proximity to the aneurysm neck, they could be related to the long-term mechanobiology of cell differentiation during fibrovascular healing of blood flow-exposed embolized aneurysms.

  16. Thermoreversible gelation polymer as an embolic material for aneurysm treatment: a delivery device for dermal fibroblasts and basic fibroblast growing factor into experimental aneurysms in rats.

    Science.gov (United States)

    Dobashi, Hisashi; Akasaki, Yasuharu; Yuki, Ichiro; Arai, Takao; Ohashi, Hiroki; Murayama, Yuichi; Takao, Hiroyuki; Abe, Toshiaki

    2013-11-01

    This study evaluates whether thermoreversible gelation polymer (TGP) can be used as a delivery device to deploy dermal fibroblasts and cytokines into experimental aneurysms in rats. The right common iliac artery of rats was surgically ligated and an experimental aneurysm was created by applying exogenous elastase. Seven days later, two aneurysms were harvested and used as controls (Group A), two were embolized with pure TGP (Group B), two were embolized with TGP and basic fibroblast growth factor (bFGF) (Group C) and two were embolized with TGP loaded with rat dermal fibroblasts (Group D). The aneurysms were also embolized with TGP mixed with dermal fibroblasts and bFGF at different concentrations (10 ng/ml: Group E (n=2), 100 ng/ml: Group F (n=2), 1000 ng/ml: Group G (n=2)). Each aneurysm sample was harvested after 7 days and histologic analyses were performed. The most advanced thrombus organization in the aneurysm, such as prominent fibroblast proliferation and collagen deposition, was observed in Groups E, F and G, although there was no noticeable difference between the groups. Moderate thrombus organization was seen in Group D and minimal thrombus organization was seen in Groups B and C. TGP mixed with both dermal fibroblasts and bFGF induced the most advanced thrombus organization in the experimental aneurysms followed by TGP mixed only with dermal fibroblasts. TGP may be useful as a delivery device to deploy fibroblasts and cytokines into aneurysms.

  17. Evolution of dosimetric phantoms

    International Nuclear Information System (INIS)

    Reddy, A.R.

    2010-01-01

    In this oration evolution of the dosimetric phantoms for radiation protection and for medical use is briefly reviewed. Some details of the development of Indian Reference Phantom for internal dose estimation are also presented

  18. Comparative Study of Cerebral Protection during Surgery of Thoracic Aortic Aneurysm

    OpenAIRE

    Sueda, Taijiro; Nomimura, Takayuki; Kagawa, Tetsuya; Morita, Satoru; Hayashi, Saiho; Orihashi, Kazumasa; Shikata, Hiroo; Ryuu, Gou; Hamanaka, Yoshiharu; Matsuura, Yuichiro; Kawaue, Yasushi; Kanehiro, Keiichi; Ishihara, Hiroshi

    1992-01-01

    During the past 5 years, 30 cases of thoracic aortic aneurysm were treated. Selective cerebral perfusion (SCP) and retrograde cerebral perfusion (RCP) were conducted for cerebral protection during aortic cross clamping. SCP was carried out in 5 cases of dissecting aneurysm (all Stanford type A, including a case of AAE) and 3 cases of arch aneurysm. RCP was conducted in 5 cases of dissecting aneurysm (4 Stanford type A; 1 Stanford type B with retrograde dissection) and 2 cases of aortic arch a...

  19. Hemodynamic and morphological characteristics of unruptured posterior communicating artery aneurysms with oculomotor nerve palsy.

    Science.gov (United States)

    Lv, Nan; Yu, Ying; Xu, Jinyu; Karmonik, Christof; Liu, Jianmin; Huang, Qinghai

    2016-08-01

    OBJECT Unruptured posterior communicating artery (PCoA) aneurysms with oculomotor nerve palsy (ONP) have a very high risk of rupture. This study investigated the hemodynamic and morphological characteristics of intracranial aneurysms with high rupture risk by analyzing PCoA aneurysms with ONP. METHODS Fourteen unruptured PCoA aneurysms with ONP, 33 ruptured PCoA aneurysms, and 21 asymptomatic unruptured PCoA aneurysms were included in this study. The clinical, morphological, and hemodynamic characteristics were compared among the different groups. RESULTS The clinical characteristics did not differ among the 3 groups (p > 0.05), whereas the morphological and hemodynamic analyses showed that size, aspect ratio, size ratio, undulation index, nonsphericity index, ellipticity index, normalized wall shear stress (WSS), and percentage of low WSS area differed significantly (p PCoA aneurysms with ONP demonstrated a distinctive morphological-hemodynamic pattern that was significantly different compared with asymptomatic unruptured PCoA aneurysms and was similar to ruptured PCoA aneurysms. The larger size, more irregular shape, and lower WSS might be related to the high rupture risk of PCoA aneurysms.

  20. Common hepatic artery aneurysm: Pseudopseudocyst of the pancreas

    International Nuclear Information System (INIS)

    Shultz, S.; Druy, E.M.; Friedman, A.C.

    1985-01-01

    The preoperative diagnosis of hepatic artery aneurysm is uncommon, and its presentation as a pancreatic mass is rare. Because of its great potential for rupture early diagnosis and treatment is essential. The authors report two cases of aneurysms of the common hepatic artery, which on CT presented as a cystic mass in the head of the pancreas. These cases illustrate the importance of using 10-mm serial sections through the pancreas after a bolus injection of intravenous contrast material in order to allow distinction between hepatic artery aneurysm and other, more common, cystic masses of the pancreas

  1. Ruptured Aortic Aneurysm From Late Type II Endoleak Treated by Transarterial Embolization

    International Nuclear Information System (INIS)

    Gunasekaran, Senthil; Funaki, Brian; Lorenz, Jonathan

    2013-01-01

    Endoleak is the most common complication after endovascular aneurysm repair. The most common type of endoleak, a type II endoleak, typically follows a benign course and is only treated when associated with increasing aneurysm size. In this case report, we describe a ruptured abdominal aortic aneurysm due to a late, type II endoleak occurring 10 years after endovascular aneurysm repair that was successfully treated by transarterial embolization.

  2. Multiple intracranial aneurysms following radiation therapy for pituitary adenoma

    International Nuclear Information System (INIS)

    Moriyama, Takumi; Shigemori, Minoru; Hirohata, Yu; Konishi, Jun; Yuge, Tatuo; Tokunaga, Takayuki; Kuramoto, Shinken.

    1992-01-01

    A rare case is reported in which multiple cerebral aneurysm occurred after radiotherapy. A female aged 51 was hospitalized with a chief complaint of consciousness disorder. The patient was discharged from the hospital 1 year before, after undergoing subtotal extirpation of a tumor through the transsphenoidal sinus in a case of pituitary adenoma, and post-operative radiotherapy (topical 50 Gy). Mild hyperlipidemia associated with hypothyroidism was observed by blood biochemical test during hospitalization. Multiple cerebral infarction was observed by CT scanning and MR imaging. Conservative treatment including intensified endocrine-supplementing treatment was performed. Thyroid gland function and hyperlipidemia improved, but the consciousness disorder occurred suddenly 6 weeks after hospitalization. Subarachnoid hemorrhage and hydrocephalus were observed by CT scanning. Cerebral angiography detected a saccular aneurysm in the trifuraction of the right middle cerebral artery, 3 fusiform aneurysms in the periphery of the right middle cerebral artery, 2 fusiform aneurysms in the posterior cerebral artery. These findings were not observed at the initial hospitalization but were unexceptionally confined to all the irradiation fields. The patient died 8 weeks after hospitalization, and no autoptic findings was obtained. We presumed that radiation vasculopathy, caused by radiation therapy done one year previously, had led to the occurrence of multiple cerebral aneurysms. We think that hyperlipidemia may have acted as an exacerbating factor responsible for these aneurysms. (author)

  3. A case of radiation induced aneurysm of extracranial carotid artery

    International Nuclear Information System (INIS)

    Tashiro, Takashi; Ikota, Toshio; Yamashita, Kousuke; Kodama, Takao

    1988-01-01

    An unusual case of post-irradiation aneurysm of extracranial internal carotid artery is presented. A 70-year-old man, complaining of left cervical throbbing mass with focal pain, was admitted on February 8, 1985. It was noted, from his past history, that he had had surgery of the removal of cervical lymphnodes and that unknown dosage of irradiation had been added to the cervical region 30 years before. Left carotid angiography (on admission) demonstrated a giant aneurysm in the cervical portion of internal carotid artery. Right carotid angiography with compression of left carotid artery revealed good cross filling through anterior communicating artery. Computed tomography with contrast media showed a ring like enhanced mass, which was thought to suggest that a large part of the aneurysm was filled with intraluminal thrombosis. During 30 days of evaluation, the aneurysm grew larger and his cervical pain became untolerable. Operation, the resection of the aneurysm and the reconstruction (of circulation) with vein graft, was challenged on March 12. It was so difficult with meticulous work that the ligation of left common carotid artery was performed after all. Seven days after the operation, he suffered from the gastrointestinal bleeding, which was enough to lead him to hypovolemic shock. Thereafter, right hemiparesis and aphasia were brought about. Two months later, he died of pneumonia. On histological examination, it was demonstrated that the aneurysm communicated with the necrotic tissue and that the normal structure of the blood vessel was not observed in the aneurysmal wall and consisted of the collagenous fiber and granulated tissue. The aneurysm was interpreted as a false one. (author)

  4. The preparation of aneurysm model in rabbits by vessel ligation and elastase-induced technique

    International Nuclear Information System (INIS)

    Lu Chuan; Xie Qianyu; Liu Linxiang

    2010-01-01

    Objective: To establish an aneurysm model, which is quite similar to the human intracranial aneurysm in morphology, in rabbits by means of vessel ligation together with elastase-induced technique. Methods: Sixteen New Zealand white rabbits were used in this study. Distal carotid ligation and intraluminal elastase incubation was employed in ten rabbits (study group) to create aneurysm on the right common carotid artery. And surgical suture of a segment of the left carotid common artery was carried out in six rabbits (used as control group) to establish the aneurysm model. DSA exam of the created aneurysms by using catheterization via femoral artery was performed at one week and at one month after surgery. The patency, morphology and pathology of the aneurysms were observed. The results were statistically analyzed. Results: The aneurysms in both groups remained patent after they were created. Angiography one week after the surgery showed that all the aneurysms in study group were patent, while in control group only two aneurysms showed opacification with contrast medium and the remaining four aneurysms were all occluded. DSA at one month after the procedure demonstrated that all the aneurysms in study group remained patent, and the previous two patent aneurysms in control group became occluded. The mean width and length of the aneurysmal cavity in study group immediately after the procedure were (3.70 ± 0.16) mm and (6.53 ± 0.65) mm respectively, which enlarged to (5.06 ± 0.31) mm and (9.0 ± 0.52) mm respectively one month after the surgery. The difference in size changes was statistically significant (P < 0.05). Pathologically, almost complete absence of the internal elastic lamina and medial wall elastin of the aneurysms was observed. Conclusion: The aneurysm model prepared with vessel ligation together with elastase-induced technique carries high patent rate and possesses the feature of spontaneous growing, moreover, its morphology is quite similar to the

  5. Splenic artery aneurysm rupture in pregnancy

    International Nuclear Information System (INIS)

    Khan, H.R.; Low, S.; Selinger, M.; Nelson, N.

    2004-01-01

    Rupture of a splenic artery aneurysm, commonly associated with pregnancy is a rare and catastrophic event. We report here a case of a patient in her second pregnancy who presented with a short history of left hypochondriac and epigastric pain, followed by collapse at 32 weeks gestation. Sudden fetal distress lead to emergency caesarean delivery when splenic artery aneurysm rupture was diagnosed. With timely involvement of multidisciplinary personnel both mother and baby survived and had an uneventful recovery. (author)

  6. Intracranial arterial aneurysm vasculopathies: targeting the outer vessel wall

    International Nuclear Information System (INIS)

    Krings, Timo; Piske, Ronie L.; Lasjaunias, Pierre L.

    2005-01-01

    The pathogenesis of intracranial arterial aneurysms (AA) remains unclear, despite their clinical importance. An improved understanding of this disease is important in choosing therapeutic options. In addition to the ''classical'' berry-type aneurysm, there are various other types of intracranial AA such as infectious, dissecting or giant, partially-thrombosed aneurysms. From the clinician's perspective, the hypothesis that some of these intracranial AA might be due to abluminal factors has been proposed for several years. Indeed, this hypothesis and the empirical use of anti-inflammatory drugs in giant intracranial aneurysms have been confirmed by recent studies reporting that an enzyme involved in the inflammatory cascade (5-lipoxygenase or 5-LO) promotes the pathogenesis of specific aneurysms in humans. 5-LO generates different forms of leukotrienes which are potent mediators of inflammation. Adventitial inflammation leads to a weakening of the media from the abluminal part of the vessel wall due to the release of proinflammatory factors that invade the media, thereby degrading the extracellular matrix, the elastic lamina of the vascular wall, and, finally, the integrity of the vessel lumen. This in turn results in a dilation of the vessel and aneurysm formation. Moreover, neoangiogenesis of vasa vasorum is found in close proximity to 5-LO activated macrophages. In addition to this biological cascade, we argue that repeated subadventitial haemorrhages from the new vasa vasorum play an important role in aneurysm pathogenesis, due to a progressive increase in size mediated by the apposition of new layers of intramural haematoma within the vessel wall. Intracranial giant AA can therefore be regarded as a proliferative disease of the vessel wall induced by extravascular activity. (orig.)

  7. Spontaneous Retroperitoneal Hemorrhage from Adrenal Artery Aneurysm

    International Nuclear Information System (INIS)

    Gonzalez Valverde, F.M.; Balsalobre, M.; Torregrosa, N.; Molto, M.; Gomez Ramos, M.J.; Vazquez Rojas, J.L.

    2007-01-01

    Spontaneous adrenal hemorrhage is a very rare but serious disorder of the adrenal gland that can require emergent treatment. We report on a 42-year-old man who underwent selective angiography for diagnosis and treatment of retroperitoneal hemorrhage from small adrenal artery aneurysm. This case gives further details about the value of transluminal artery embolization in the management of visceral aneurysm rupture

  8. Giant aneurysm in a left coronary artery fistula

    DEFF Research Database (Denmark)

    Frestad, Daria; Helqvist, Steffen; Helvind, Morten

    2013-01-01

    Congenital coronary artery fistula complicated with giant coronary artery aneurysm is a very rare condition. In this case report, we present a 65-year-old woman, referred to us with a continuous heart murmur, occasional atypical chest pain and few episodes of fainting. A giant aneurysm...

  9. Aneurysm and dissection in a patient with syphilitic aortitis

    Directory of Open Access Journals (Sweden)

    Fernando Pivatto Júnior

    2017-05-01

    Full Text Available In the antibiotic era, aortic aneurysm is a rare complication of syphilis, what makes the diagnostic assumption even more difficult. Nonetheless, this condition should be suspected in patients with aortic aneurysm. Reports of aortic dissection complicating syphilitic aortitis have been distinctly rare in the literature, and their cause-effect relationship has not been definitely established. In this case report, we present a 62-year-old woman with aortic aneurysm and dissection associated with an unexpected diagnosis of syphilitic aortitis.

  10. DSA volumetric 3D reconstructions of intracranial aneurysms: A pictorial essay

    Science.gov (United States)

    Cieściński, Jakub; Serafin, Zbigniew; Strześniewski, Piotr; Lasek, Władysław; Beuth, Wojciech

    2012-01-01

    Summary A gold standard of cerebral vessel imaging remains the digital subtraction angiography (DSA) performed in three projections. However, in specific clinical cases, many additional projections are required, or a complete visualization of a lesion may even be impossible with 2D angiography. Three-dimensional (3D) reconstructions of rotational angiography were reported to improve the performance of DSA significantly. In this pictorial essay, specific applications of this technique are presented in the management of intracranial aneurysms, including: preoperative aneurysm evaluation, intraoperative imaging, and follow-up. Volumetric reconstructions of 3D DSA are a valuable tool for cerebral vessels imaging. They play a vital role in the assessment of intracranial aneurysms, especially in evaluation of the aneurysm neck and the aneurysm recanalization. PMID:22844309

  11. Cavitation instability as a trigger of aneurysm rupture.

    Science.gov (United States)

    Volokh, K Y

    2015-10-01

    Aneurysm formation and growth is accompanied by microstructural alterations in the arterial wall. Particularly, the loss of elastin may lead to tissue disintegration and appearance of voids or cavities at the micron scale. Unstable growth and coalescence of voids may be a predecessor and trigger for the onset of macroscopic cracks. In the present work, we analyze the instability of membrane (2D) and bulk (3D) voids under hydrostatic tension by using two experimentally calibrated constitutive models of abdominal aortic aneurysm enhanced with energy limiters. The limiters provide the saturation value for the strain energy, which indicates the maximum energy that can be stored and dissipated by an infinitesimal material volume. We find that the unstable growth of voids can start when the critical stress is considerably less than the aneurysm strength. Moreover, this critical stress may even approach the arterial wall stress in the physiological range. This finding suggests that cavitation instability can be a rational indicator of the aneurysm rupture.

  12. Diagnosis of ruptured intracranial aneurysm in acute stage

    International Nuclear Information System (INIS)

    Yoshiyama, Masataka; Nakagawa, Toshifumi

    1980-01-01

    Subarachnoid hemorrhage at an acute stage within one day from the onset to the first CT scan was classified into subarachnoid hemorrhage secondary to intracranial aneurysm, subarachnoid hemorrhage of unknown origin and subarachnoid hemorrhage of which angiography could not be carried out, and the first CT findings, the severity, and the prognosis of these subarachnoid hemorrhage were compared and discussed. CT findings of subarachnoid hemorrhage secondary to intracranial aneurysm showed various changes according to progress in the severity with time, and intracranial hematoma, intraventricular clots and ventricular dilatation increased according to progress in the severity. Ruptured intracranial aneurysm in middle cerebral artery, anterior cerebral artery and anterior communicating artery could be found easily by CT, but that in internal carotid artery and vertabral basilar artery was difficult to be detected by CT. When cerebral angiography was carried out repeatedly for ruptured intracranial aneurysm of unknown origin, the time of performance must be consifered with attention to angiospasms or hematoma. (Tsunoda, M.)

  13. Experimental studies on canine terminal carotid arterial aneurysm models pre- and post-embolized with microcoil

    International Nuclear Information System (INIS)

    Wang Qihong; Zhou Liangfu; Gong Jianqiu; Dai Jianhua; Zhang Xiaojun; Zhang Xinyuan

    2005-01-01

    Objective: To establish canine terminal saccular aneurysm model of common carotid artery (CCA), and evaluate the images and hemodynamic changes of aneurysm cavities pre- and post-embolized with microcoil (MC). Methods: Seven CCA terminal saccular aneurysm models had been created by using improved microsurgical technique. Seven to fourteen days after surgery, models were undergone color Doppler, Magnetic resonance image (MRI), Magnetic resonance angiography (MRA), digital subtraction angiography (DSA), and then the analysis of computational fluid dynamics (CFD) on these animal models were conducted. Afterwards they were compactly packed with MC, and then aneurysms again were examed under these methods, and simulation of pathological changes. Results: Models were created successfully with good MC compactly pack aneurysm cavities. DSA combined with other imaging methods can improve the diagnosis of aneurysms completely. CFD models can show the imitation hemodynamics of canine carotid aneurysms. Conclusions: This kind of aneurysm model is an ideal one on the area for the research of aneurysm embolization. Non-DSA imaging examination can noninvasively, repeatedly, clearly evaluate aneurysms pre- and post-embolized with MC. The interference on the inflow zone of the aneurysm is an effective method for cure and preventing recurrence of aneurysms. (authors)

  14. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    International Nuclear Information System (INIS)

    Mühlenbruch, Georg; Nikoubashman, Omid; Steffen, Björn; Dadak, Mete; Palmowski, Moritz; Wiesmann, Martin

    2013-01-01

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  15. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenbruch, Georg, E-mail: gmuehlenbruch@ukaachen.de; Nikoubashman, Omid; Steffen, Bjoern; Dadak, Mete [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany); Palmowski, Moritz [RWTH Aachen University, Department of Nuclear Medicine, University Hospital (Germany); Wiesmann, Martin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany)

    2013-02-15

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  16. Analysis of blood flow patterns in aortic aneurysm by cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Matsuoka, Hiroshi

    1993-01-01

    Cine MRI (0.5 T) using rephased gradient echo technique was performed to study the patterns of blood flow in the aortic aneurysm of 16 patients with aortic aneurysm, and the data were compared with those of 5 healthy volunteers. In the transaxial section, the blood flow in normal aorta appeared as homogeneous high intensity during systole. On the other hand, the blood flow in the aneurysm appeared as inhomogeneous flow enhancement with flow void. In the sagittal scan, the homogeneous flow enhancement in a normal aorta was also observed during systole and its apex of flow enhancement was 'taper'. The blood flow patterns in the aneurysm were classified as 'irregular', 'zonal', 'eddy', and 'obscure' depending on the contrast of flow enhancement and flow void. Their apexes were 'taper' or 'round'. The blood flow patterns in the aneurysm were related to the size of aneurysm. In patients with a large size 'aneurysm, their flow patterns were 'eddy' or 'obscure' and the flow enhancement was 'round'. On the other hand, in patients with a small size aneurysm, their flow patterns were 'irregular' or 'zonal', and their flow enhancement was 'taper'. Though the exact mechanism of abnormal flow patterns in an aortic aneurysm remains to be determined, cine MRI gives helpful informations in assessing blood flow dynamics in the aneurysm. (author)

  17. Comparison of Enterprise with Neuroform stent-assisted coiling of intracranial aneurysms.

    Science.gov (United States)

    Kadkhodayan, Yasha; Rhodes, Nicholas; Blackburn, Spiros; Derdeyn, Colin P; Cross, DeWitte T; Moran, Christopher J

    2013-04-01

    The Enterprise stent is the first closed-cell stent designed to treat wide-necked intracranial aneurysms. Advantages of the design can include improvement in keeping coils within an aneurysm and the ability of the stent to be recaptured. We compared the technical and clinical complications of the Enterprise stent with the open-cell Neuroform stent, its primary alternative. Patients undergoing Enterprise and Neuroform stent-assisted aneurysm coiling were enrolled in prospective registries starting in March 2007 and February 2003, respectively. All consecutive patients through December 2011 were included. Deployment success and difficulty, stent movement and misplacement, and procedural complications were compared. Enterprise deployment success was high (108 of 115 attempts, 93.9%) with 102 aneurysms receiving a stent compared with Neuroform (173 of 214 attempts, 80.8%, p = 0.001) with 163 aneurysms. Enterprise was easier to deploy (1.7% vs 15.9% difficult deployment, p Enterprise stent (8.7% vs 1.4%, p = 0.0021). The Enterprise stent enabled treatment of 10 additional aneurysms that could not be treated with Neuroform and had a higher rate of immediate aneurysm occlusion (87.3% vs 73.0%, p = 0.0058). Enterprise was easier to deploy and enabled treatment of additional aneurysms; however, there were more thromboembolic complications. On the basis of these findings, we prefer to use the Neuroform stent first and rely on the Enterprise stent as an easy-to-deliver backup for stent-assisted coiling.

  18. Endoluminal embolization of bilateral atherosclerotic common iliac aneurysms with fibrin tissue glue (Beriplast)

    International Nuclear Information System (INIS)

    Beese, Richard C.; Tomlinson, Mark A.; Buckenham, Timothy M.

    2000-01-01

    The standard surgical approach to nonleaking iliac aneurysms found at repair of a leaking abdominal aortic aneurysm is to minimize the operative risk by repairing the abdominal aorta only. This means that the bypassed iliac aneurysms may have to be repaired later. As this population of patients are usually elderly with coexisting medical problems, interventional radiology is being used to embolize these aneurysms, thus avoiding the morbidity and mortality associated with further general anesthesia and surgery. Various materials and stents have been reported to be effective in the treatment of iliac aneurysms. We report the successful use of endoluminal fibrin tissue glue (Beriplast) to treat two large iliac aneurysms in a patient who had had a previous abdominal aortic aneurysm repair. We discuss the technique involved and the reasons why we used tissue glue in this patient.

  19. A novel flow diverter(Tubridge) for the treatment of recurrent aneurysms: A single-center experience

    International Nuclear Information System (INIS)

    Zhang, Yong Xin; Huang, Qing Hai; Fang, Yibin; Yang, Peng Fei; Xu, Yi; Hong Bo; Liu, Jian Min

    2017-01-01

    The Tubridge flow diverter (FD) is a novel device aimed at reconstructing the parent artery and occluding complex aneurysms. Retreatment of recurrent aneurysms using the FD is challenging. We report our initial experience in the repair of aneurysm recurrence with the FD. A database was reviewed prospectively, and 8 patients with 8 recurrent aneurysms (mean size, 16.7 mm) were identified. Four aneurysms had previously ruptured. The previous aneurysm treatment consisted of coiling in 1 aneurysm and single-stent-assisted coiling in 7 aneurysms. The procedural complications and clinical and angiographic outcomes were analyzed. Six aneurysms were treated by using a single Tubridge FD alone, while the remaining 2 were treated with FD + coiling. The immediate results of the 8 aneurysms were that they all showed incomplete occlusion. Neither major ischemic nor hemorrhagic complications occurred; however, 1 patient experienced a vasospasm. Follow-up angiographies were available for 7 aneurysms; the mean follow-up was 16.9 months (7–36 months). Five aneurysms were completely occluded, whereas 2 had a residual neck. Severe asymptomatic stenosis of 1 parent artery of a vertebral artery dissecting aneurysm was found. All visible branches covered by the FD were patent. All patients were clinically assessed as having attained a favorable outcome (modified Rankin Scale score ≤ 2) at discharge and follow-up. In selected patients, the Tubridge FD can provide a safe and efficient option for the retreatment of recurrent aneurysms. Nevertheless, attention should be paid to several technical points

  20. A novel flow diverter(Tubridge) for the treatment of recurrent aneurysms: A single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yong Xin; Huang, Qing Hai; Fang, Yibin; Yang, Peng Fei; Xu, Yi; Hong Bo; Liu, Jian Min [Dept. of Neurosurgery, Changhai Hospital, Second Military Medical University, Shanghai (China)

    2017-09-15

    The Tubridge flow diverter (FD) is a novel device aimed at reconstructing the parent artery and occluding complex aneurysms. Retreatment of recurrent aneurysms using the FD is challenging. We report our initial experience in the repair of aneurysm recurrence with the FD. A database was reviewed prospectively, and 8 patients with 8 recurrent aneurysms (mean size, 16.7 mm) were identified. Four aneurysms had previously ruptured. The previous aneurysm treatment consisted of coiling in 1 aneurysm and single-stent-assisted coiling in 7 aneurysms. The procedural complications and clinical and angiographic outcomes were analyzed. Six aneurysms were treated by using a single Tubridge FD alone, while the remaining 2 were treated with FD + coiling. The immediate results of the 8 aneurysms were that they all showed incomplete occlusion. Neither major ischemic nor hemorrhagic complications occurred; however, 1 patient experienced a vasospasm. Follow-up angiographies were available for 7 aneurysms; the mean follow-up was 16.9 months (7–36 months). Five aneurysms were completely occluded, whereas 2 had a residual neck. Severe asymptomatic stenosis of 1 parent artery of a vertebral artery dissecting aneurysm was found. All visible branches covered by the FD were patent. All patients were clinically assessed as having attained a favorable outcome (modified Rankin Scale score ≤ 2) at discharge and follow-up. In selected patients, the Tubridge FD can provide a safe and efficient option for the retreatment of recurrent aneurysms. Nevertheless, attention should be paid to several technical points.

  1. Mycotic pulmonary artery aneurysm as an unusual complication of thoracic actinomycosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung-Soo; Lee, Sang-Yeub [Wonkwang University College, Iksan (Korea, Republic of); Oh, Yu-Whan; Noh, Hyung-Jun; Lee, Ki-Yeol; Kang, Eun-Young [Korea University Hospital and Korea University College, Seoul (Korea, Republic of)

    2004-03-15

    Although pulmonary artery aneurysms are a rare vascular anomaly, they are seen in a wide variety of conditions, such as congenital heart disease, infection, trauma, pulmonary hypertension, cystic medial necrosis and generalized vasculitis. To our knowledge, mycotic aneurysms caused by pulmonary actinomycosis have not been reported in the radiologic literature. Herein, a case of pulmonary actinomycosis complicated by mycotic aneurysm is presented. On CT scans, this case showed focal aneurysmal dilatation of a peripheral pulmonary artery within necrotizing pneumonia of the right lower lobe, which was successfully treated with transcatheter embolization using wire coils.

  2. Mycotic pulmonary artery aneurysm as an unusual complication of thoracic actinomycosis

    International Nuclear Information System (INIS)

    Kim, Hyung-Soo; Lee, Sang-Yeub; Oh, Yu-Whan; Noh, Hyung-Jun; Lee, Ki-Yeol; Kang, Eun-Young

    2004-01-01

    Although pulmonary artery aneurysms are a rare vascular anomaly, they are seen in a wide variety of conditions, such as congenital heart disease, infection, trauma, pulmonary hypertension, cystic medial necrosis and generalized vasculitis. To our knowledge, mycotic aneurysms caused by pulmonary actinomycosis have not been reported in the radiologic literature. Herein, a case of pulmonary actinomycosis complicated by mycotic aneurysm is presented. On CT scans, this case showed focal aneurysmal dilatation of a peripheral pulmonary artery within necrotizing pneumonia of the right lower lobe, which was successfully treated with transcatheter embolization using wire coils

  3. Ruptured aortic aneurysm in a coyote (Canis latrans) from South Carolina.

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Debra, Lee; Schrecengost, Joshua; Kilgo, John; Ray, Scott; Miller, Karl V.

    2007-07-01

    Abstract – A radio-collared adult female coyote (Canis latrans) from South Carolina was found dead with no apparent signs of trauma or struggle. Necropsy revealed a ruptured aortic aneurysm within the thoracic cavity as well as severe heartworm infection, with paracites present in the caudal vena cava. Histologically, inflammatory cell infiltrates were frequent in the aneurysm and consisted of eosinophils, neutrophils, lymphocytes, plasma cells, and macrophages. Bacteria, fungi, and paracites were not found in the aneurysm. Death was due to exsanguinations. This represents a first report of an aneurysm in a coyote.

  4. Hemodynamic patterns of anterior communicating artery aneurysms: a possible association with rupture

    Science.gov (United States)

    Castro, Marcelo A.; Putman, Christopher M.; Cebral, Juan R.

    2007-03-01

    The aim of this study is to characterize the different flows present at anterior communicating artery (AcoA) aneurysms and investigate possible associations with rupture. For that purpose, patient-specific computational models of 26 AcoA aneurysms were constructed from 3D rotational angiography images. Bilateral images were acquired in 15 patients who had both A1 segments of the anterior cerebral arteries and models were created by fusing the reconstructed left and right arterial trees. Computational fluid dynamics simulations were performed under pulsatile flow conditions. Visualizations of the flow velocity pattern were created to classify the aneurysms into the following flow types: A) inflow from both A1 segments, B) flow jet in the parent artery splits into three secondary jets, one enters the aneurysm and the other two are directed to the A2 segments, C) the parent artery jet splits into two secondary jets, one is directed to one of the A2 segments and the other enters the aneurysm before being directed to the other A2 segment, and D) the parent artery jet enters the aneurysm before being directed towards the A2 segments. The maximum wall shear stress in the aneurysm at the systolic peak (MWSS) was calculated. Most aneurysms in group A were unruptured and had the lowest MWSS. Group B had the same number of unruptured and ruptured aneurysms, and a low MWSS. Groups C and D had high rupture ratios, being the average MWSS significantly higher in group C. Finally, it was found that the MWSS was higher for ruptured aneurysms of all flow types.

  5. Development of a static bioactive stent prototype and dynamic aneurysm-on-a-chip(TM) model for the treatment of aneurysms

    Science.gov (United States)

    Reece, Lisa M.

    Aneurysms are pockets of blood that collect outside blood vessel walls forming dilatations and leaving arterial walls very prone to rupture. Current treatments include: (1) clipping, and (2) coil embolization, including stent-assisted coiling. While these procedures can be effective, it would be advantageous to design a biologically active stent, modified with magnetic stent coatings, allowing cells to be manipulated to heal the arterial lining. Further, velocity, pressure, and wall shear stresses aid in the disease development of aneurysmal growth, but the shear force mechanisms effecting wound closure is elusive. Due to these factors, there is a definite need to cultivate a new stent device that will aid in healing an aneurysm in situ. To this end, a static bioactive stent device was synthesized. Additionally, to study aneurysm pathogenesis, a lab-on-a-chip device (a dynamic stent device) is the key to discovering the underlying mechanisms of these lesions. A first step to the reality of a true bioactive stent involves the study of cells that can be tested against the biomaterials that constitute the stent itself. The second step is to test particles/cells in a microfluidic environment. Therefore, biocompatability data was collected against PDMS, bacterial nanocellulose (BNC), and magnetic bacterial nanocellulose (MBNC). Preliminary static bioactive stents were synthesized whereby BNC was grown to cover standard nitinol stents. In an offshoot of the original research, a two-dimensional microfluidic model, the Aneurysm-on-a-ChipTM (AOC), was the logical answer to study particle flow within an aneurysm "sac" - this was the dynamic bioactive stent device. The AOC apparatus can track particles/cells when it is coupled to a particle image velocimetry software (PIV) package. The AOC fluid flow was visualized using standard microscopy techniques with commercial microparticles/cells. Movies were taken during fluid flow experiments and PIV was utilized to monitor.

  6. Indentification of inflow zone of cerebral aneurysm by MRA for effective coil embolization

    International Nuclear Information System (INIS)

    Kudo, Takumi; Satow, Tetsu; Yamada, Naoaki; Hyuga, Takanori; Miyamoto, Susumu; Murao, Kenichi

    2008-01-01

    It is important to pack the inflow zone of intracerebral aneurysm to prevent coil compaction or recanalization after coil embolization of the aneurysm. In this study, we report the usefulness of magnetic resonance angiography (MRA) to identify the inflow zone of the aneurysm. Between November 2004 and March 2006, 21 patients (IC paraclinoid, 11 cases; BA tip, 3 cases; A-com, 4 cases; IC-top, 2 cases; P1, 1 case) underwent interventional coil embolization for cerebral aneurysms and MRA was used to try to depict the inflow zone of the aneurysm. We designed a 3D time-of-flight MRA technique targeted to the aneurysm with a large flip angle to emphasize the streamline into the aneurysm. We grasped the position of the inflow zone in the aneurysm by MRA before intervention. The inflow zone was packed by coils tightly with balloon neck remodeling technique anchor catheter assist technique, if necessary. The inflow zone was depicted in all 21 cases by MRA. In sidewall type aneurysms, the inflow zone existed beside the distal neck in all cases. In terminal type aneurysms, the inflow zone existed on an extension line from patent artery. Dome filling was not detected in all cases after treatment. Small neck remnant was detected in 6 cases that slightly increased in 4 cases, vanished in 1 case, remained and unchanged in 1 case 6 months after treatment. None of the cases required additional treatment. For effective coil embolization, it is important to grasp the position of the inflow zone of the aneurysm and to pack the point as tightly as possible. Identification of the inflow zone of aneurysm by MRA is useful for coil embolization. (author)

  7. Application of a novel retrievable self-expanding stent in intracranial aneurysm treatment

    International Nuclear Information System (INIS)

    Yang Zhigang; Liu Jianmin; Xu Yi; Huang Qinghai; Hong Bo; Zhao Wenyuan; Zhao Rui

    2008-01-01

    Objective: To assess the value of a novel retrievable self-expanding stent system (LEO) in intracranial aneurysm treatment. Methods: 43 patients with 44 intracranial aneurysms treated with LEO stent were retrospectively analized, including 16 aneurysms with single-stent deployment, 25 with stent-assisted technique, 2 with double-stent deployment and one with double-stent assisted coils. Follow up was carried out through imaging and clinical course. Results: The stent was easy for repositioning and all the stents were delivered successfully, except 1 stent with unsatisfactory position, 1 with acute in-stent thrombosis. During follow up, 1 case showed chronic in-stent thrombus and one with intimal hyperplasia. 22 aneurysms got compact coiled during procedure. Among 29 follow up cases, 72.4% aneurysms were cured or improved, 13.8% were stable and three dissection aneurysms enlarged within short period and two patients died. Conclusion: The new retrievable self-expanding stent (LEO), with the advantages of controlled delivery, easy deployment and choice for various types is a valuable system for vascular reconstruction of intracranial aneurysm with thrombosis. (authors)

  8. The impact of anthropometric patient-phantom matching on organ dose: A hybrid phantom study for fluoroscopy guided interventions

    International Nuclear Information System (INIS)

    Johnson, Perry B.; Geyer, Amy; Borrego, David; Ficarrotta, Kayla; Johnson, Kevin; Bolch, Wesley E.

    2011-01-01

    Purpose: To investigate the benefits and limitations of patient-phantom matching for determining organ dose during fluoroscopy guided interventions. Methods: In this study, 27 CT datasets representing patients of different sizes and genders were contoured and converted into patient-specific computational models. Each model was matched, based on height and weight, to computational phantoms selected from the UF hybrid patient-dependent series. In order to investigate the influence of phantom type on patient organ dose, Monte Carlo methods were used to simulate two cardiac projections (PA/left lateral) and two abdominal projections (RAO/LPO). Organ dose conversion coefficients were then calculated for each patient-specific and patient-dependent phantom and also for a reference stylized and reference hybrid phantom. The coefficients were subsequently analyzed for any correlation between patient-specificity and the accuracy of the dose estimate. Accuracy was quantified by calculating an absolute percent difference using the patient-specific dose conversion coefficients as the reference. Results: Patient-phantom matching was shown most beneficial for estimating the dose to heavy patients. In these cases, the improvement over using a reference stylized phantom ranged from approximately 50% to 120% for abdominal projections and for a reference hybrid phantom from 20% to 60% for all projections. For lighter individuals, patient-phantom matching was clearly superior to using a reference stylized phantom, but not significantly better than using a reference hybrid phantom for certain fields and projections. Conclusions: The results indicate two sources of error when patients are matched with phantoms: Anatomical error, which is inherent due to differences in organ size and location, and error attributed to differences in the total soft tissue attenuation. For small patients, differences in soft tissue attenuation are minimal and are exceeded by inherent anatomical differences

  9. Wall stress on ascending thoracic aortic aneurysms with bicuspid compared with tricuspid aortic valve.

    Science.gov (United States)

    Xuan, Yue; Wang, Zhongjie; Liu, Raymond; Haraldsson, Henrik; Hope, Michael D; Saloner, David A; Guccione, Julius M; Ge, Liang; Tseng, Elaine

    2018-03-08

    Guidelines for repair of bicuspid aortic valve-associated ascending thoracic aortic aneurysms have been changing, most recently to the same criteria as tricuspid aortic valve-ascending thoracic aortic aneurysms. Rupture/dissection occurs when wall stress exceeds wall strength. Recent studies suggest similar strength of bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms; thus, comparative wall stress may better predict dissection in bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms. Our aim was to determine whether bicuspid aortic valve-ascending thoracic aortic aneurysms had higher wall stresses than their tricuspid aortic valve counterparts. Patients with bicuspid aortic valve- and tricuspid aortic valve-ascending thoracic aortic aneurysms (bicuspid aortic valve = 17, tricuspid aortic valve = 19) greater than 4.5 cm underwent electrocardiogram-gated computed tomography angiography. Patient-specific 3-dimensional geometry was reconstructed and loaded to systemic pressure after accounting for prestress geometry. Finite element analyses were performed using the LS-DYNA solver (LSTC Inc, Livermore, Calif) with user-defined fiber-embedded material model to determine ascending thoracic aortic aneurysm wall stress. Bicuspid aortic valve-ascending thoracic aortic aneurysms 99th-percentile longitudinal stresses were 280 kPa versus 242 kPa (P = .028) for tricuspid aortic valve-ascending thoracic aortic aneurysms in systole. These stresses did not correlate to diameter for bicuspid aortic valve-ascending thoracic aortic aneurysms (r = -0.004) but had better correlation to tricuspid aortic valve-ascending thoracic aortic aneurysms diameter (r = 0.677). Longitudinal stresses on sinotubular junction were significantly higher in bicuspid aortic valve-ascending thoracic aortic aneurysms than in tricuspid aortic valve-ascending thoracic aortic aneurysms (405 vs 329 kPa, P = .023). Bicuspid

  10. Enterprise Deployment Through PulseRider To Treat Anterior Communicating Artery Aneurysm Recurrence.

    Science.gov (United States)

    Valente, Iacopo; Limbucci, Nicola; Nappini, Sergio; Rosi, Andrea; Laiso, Antonio; Mangiafico, Salvatore

    2018-02-01

    PulseRider (Pulsar Vascular, Los Gatos, California, USA) is a new endovascular device designed to treat wide-neck bifurcation intracranial aneurysms. Deployment of a stent through a PulseRider to treat an aneurysm's recurrence has never been described before. We report the case of a 55-year-old man who underwent coiling of an 8-mm anterior communicating artery aneurysm with assistance of a PulseRider neck reconstruction device. The 6-month digital subtraction angiography control showed aneurysm recurrence, so we deployed an Enterprise 2 closed-cell stent (Codman, Miami Lakes, Florida, USA) in the A1-A2 segment passing across the previously implanted PulseRider. Enterprise correctly expanded and allowed for adequate coiling of the aneurysm. An Enterprise stent can be safely opened through a PulseRider in order to treat aneurysm recurrence. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. 3D Printing Openable Imaging Phantom Design

    International Nuclear Information System (INIS)

    Kim, Myoung Keun; Won, Jun Hyeok; Lee, Seung Wook

    2017-01-01

    The purpose of this study is to design an openable phantom that can replace the internal measurement bar used for contrast comparison in order to increase the efficiency of manufacturing imaging phantom used in the medical industry and to improve convenience using 3D printer. Phantom concept design, 3D printing, and Image reconstruction were defined as the scope of the thesis. Also, we study metal artifact reduction with openable phantom. We have designed a Openable phantom using 3D printing, and have investigated metal artifact reduction after inserting a metallic material inside the phantom. The openable phantom can be adjusted at any time to suit the user's experiment and can be easily replaced and useful.

  12. Endovascular treatment of basilar tip aneurysms associated with moyamoya disease

    International Nuclear Information System (INIS)

    Arita, K.; Kurisu, K.; Ohba, S.; Shibukawa, M.; Kiura, H.; Sakamoto, S.; Uozumi, T.; Nakahara, T.

    2003-01-01

    We report the efficacy and safety of endovascular treatment of basilar tip aneurysms (BTA) in five patients with moyamoya disease. The patients underwent intra-aneurysmal embolisation with detachable platinum coils. Three BTA presented with subarachnoid haemorrhage (SAH); the other two were asymptomatic. In four cases, one embolisation procedure produced >95% angiographic obliteration of the aneurysm. In the other patient, 80-90% obliteration was achieved initially, but due to growth of the residual aneurysm, the procedure was repeated 7 months later. Two patients experienced transient oculomotor paresis as a procedure-related complication. Mean follow-up was 43.6±34.0 months (range 8-92 months). One patient died of putaminal haemorrhage unrelated to the aneurysm 15 months after embolisation. The other four had no subsequent SAH and survived without sequelae. Endovascular embolisation using detachable platinum coils proved to be a safe and efficient treatment modality for BTA associated with moyamoya disease. (orig.)

  13. Asymptomatic giant coronary aneurysm in an adolescent with Behcet's syndrome

    Directory of Open Access Journals (Sweden)

    Kahn Philip J

    2012-01-01

    Full Text Available Abstract Objective Behcet's is an idiopathic multi-organ syndrome, which may have onset during childhood. Vascular involvement is uncommon, with rarely reported coronary aneurysm formation. We present a case report of a teenager girl who developed recalcitrant life-threatening Behcet's vasculitis, involving both small and large venous and arterial systems including a giant coronary aneurysm. Case report De-identified data were collected retrospectively in case report format. Although our sixteen year old female with Behcet's vasculitis had resolution of many arterial aneurysms, she had persistent venous thrombosis of large vessels, as well as persistent, giant arterial aneurysms requiring intra-arterial coiling of a lumbar artery and coronary bypass grafting despite intensive immunosuppression including glucocorticoids, cyclophosphamide, infliximab, methotrexate, azathioprine and intravenous immunoglobulin. Conclusions Vascular manifestations may be seen in Behcet's syndrome, including asymptomatic coronary aneurysm, which may be refractory to immunosuppression and ultimately require surgical intervention. Increased awareness is essential for prompt diagnosis and management.

  14. Transcatheter Embolization of a Renal Artery Aneurysm Using Ethylene Vinyl Alcohol Copolymer

    International Nuclear Information System (INIS)

    Rautio, Riitta; Haapanen, Arto

    2007-01-01

    Our aim was to treat a clinically silent renal artery aneurysm. The patient was a 76-year-old man with elevated prostate-specific antigen and prostata biopsies with a gradus II-III adenocarcinoma who was incidentally found to have an aneurysm in his right renal artery. We performed a successful transcatheter embolization of the aneurysm using ethylene vinyl alcohol copolymer (Onyx). To avoid migration of the liquid material into the parent artery, a balloon was inflated in the orifice of the neck of the aneurysm while the liquid was injected. Five-month follow-up computed tomography (CT) imaging confirmed total occlusion of the aneurysm

  15. Pulmonary artery aneurysm

    African Journals Online (AJOL)

    Enrique

    Introduction. Pulmonary artery aneurysms are a rare finding in general radiological practice. The possible causes are myriad and diverse in pathophysiolo- gy. Patients with post-stenotic dilata- tion of the main pulmonary artery usually present fairly late with insidi- ous cardiorespiratory symptoms. Diagnosis requires ...

  16. Aneurysmal bone cyst and other nonneoplastic conditions

    International Nuclear Information System (INIS)

    Dahlin, D.C.; McLeod, R.A.

    1982-01-01

    Aneurysmal bone cyst is a benign proliferative tumefaction of bone. Histologic similarities indicate a kinship among classic aneurysmal bone cysts, essentially 'solid' proliferative lesions in bones; giant cell reparative granulomas of the jaws, at the base of the skull, and in the small bones of the hands and feet; skeletal lesions of hyperparathyroidism; and even pseudosarcomatous myositis ossificans, proliferative myositis, and proliferative fasciitis. (orig.)

  17. Aneurysmal malformation of the extrahepatic portal vein: a case report

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Kang, Sung Soo; Kim, Chong Soo; Han, Hyeun Young

    1999-01-01

    Aneurysmal malformation of the portal vein is a rare entity. To our knowledge, only scattered reports of portal vein aneurysms appear in the literature in English, and there is no previously published report in Korean. We describe a case exhibiting aneurysmal malformation of the extrahepatic portal vein at the hepatic hilum ; the findings demonstrated by ultrasound, CT and angiography are discussed, a review of previously described cases is included

  18. Diagnosing aneurysmal and unicameral bone cysts with magnetic resonance imaging.

    Science.gov (United States)

    Sullivan, R J; Meyer, J S; Dormans, J P; Davidson, R S

    1999-09-01

    The differential between aneurysmal bone cysts and unicameral bone cysts usually is clear clinically and radiographically. Occasionally there are cases in which the diagnosis is not clear. Because natural history and treatment are different, the ability to distinguish between these two entities before surgery is important. The authors reviewed, in a blinded fashion, the preoperative magnetic resonance images to investigate criteria that could be used to differentiate between the two lesions. All patients had operative or pathologic confirmation of an aneurysmal bone cyst or unicameral bone cyst. The authors analyzed the preoperative magnetic resonance images of 14 patients with diagnostically difficult bone cysts (eight children with unicameral bone cysts and six children with aneurysmal bone cysts) and correlated these findings with diagnosis after biopsy or cyst aspiration and contrast injection. The presence of a double density fluid level within the lesion strongly indicated that the lesion was an aneurysmal bone cyst, rather than a unicameral bone cyst. Other criteria that suggested the lesion was an aneurysmal bone cyst were the presence of septations within the lesion and signal characteristics of low intensity on T1 images and high intensity on T2 images. The authors identified a way of helping to differentiate between aneurysmal bone cysts and unicameral bone cysts on magnetic resonance images. Double density fluid level, septation, and low signal on T1 images and high signal on T2 images strongly suggest the bone cyst in question is an aneurysmal bone cyst, rather than a unicameral bone cyst. This may be helpful before surgery for the child who has a cystic lesion for which radiographic features do not allow a clear differentiation of unicameral bone cyst from aneurysmal bone cyst.

  19. Percutaneous treatment of a ruptured superior mesenteric artery aneurysm in a child

    Energy Technology Data Exchange (ETDEWEB)

    Oechsle, Susanne; Vollert, Kurt; Buecklein, Wolfgang; Michl, Wolfgang; Roemer, Frank W. [Klinikum Augsburg, Department of Radiology, Augsburg (Germany)

    2006-03-15

    Splanchnic artery aneurysms are very rare in children. We report a 10-year-old girl with a large atraumatic ruptured superior mesenteric artery aneurysm that was considered inoperable. She was ultimately treated with two percutaneous US-guided thrombin injections, which led to complete occlusion of the aneurysm. The aetiology of the aneurysm remained unclear, but a family history was suggestive of a congenital connective tissue disease such as Ehlers-Danlos syndrome subtype IV. (orig.)

  20. Percutaneous treatment of a ruptured superior mesenteric artery aneurysm in a child

    International Nuclear Information System (INIS)

    Oechsle, Susanne; Vollert, Kurt; Buecklein, Wolfgang; Michl, Wolfgang; Roemer, Frank W.

    2006-01-01

    Splanchnic artery aneurysms are very rare in children. We report a 10-year-old girl with a large atraumatic ruptured superior mesenteric artery aneurysm that was considered inoperable. She was ultimately treated with two percutaneous US-guided thrombin injections, which led to complete occlusion of the aneurysm. The aetiology of the aneurysm remained unclear, but a family history was suggestive of a congenital connective tissue disease such as Ehlers-Danlos syndrome subtype IV. (orig.)

  1. The subresolution DaTSCAN phantom: a cost-effective, flexible alternative to traditional phantom technology.

    Science.gov (United States)

    Taylor, Jonathan C; Vennart, Nicholas; Negus, Ian; Holmes, Robin; Bandmann, Oliver; Lo, Christine; Fenner, John

    2018-03-01

    The Alderson striatal phantom is frequently used to assess I-FP-CIT (Ioflupane) image quality and to test semi-quantification software. However, its design is associated with a number of limitations, in particular: unrealistic image appearances and inflexibility. A new physical phantom approach is proposed on the basis of subresolution phantom technology. The design incorporates thin slabs of attenuating material generated through additive manufacturing, and paper sheets with radioactive ink patterns printed on their surface, created with a conventional inkjet printer. The paper sheets and attenuating slabs are interleaved before scanning. Use of thin layers ensures that they cannot be individually resolved on reconstructed images. An investigation was carried out to demonstrate the performance of such a phantom in producing simplified I-FP-CIT uptake patterns. Single photon emission computed tomography imaging was carried out on an assembled phantom designed to mimic a healthy patient. Striatal binding ratio results and linear striatal dimensions were calculated from the reconstructed data and compared with that of 22 clinical patients without evidence of Parkinsonian syndrome, determined from clinical follow-up. Striatal binding ratio results for the fully assembled phantom were: 3.1, 3.3, 2.9 and 2.6 for the right caudate, left caudate, right putamen and right caudate, respectively. All were within two SDs of results derived from a cohort of clinical patients. Medial-lateral and anterior-posterior dimensions of the simulated striata were also within the range of values seen in clinical data. This work provides the foundation for the generation of a range of more clinically realistic, physical phantoms.

  2. Treatment of ruptured intracranial aneurysms: implications of the ISAT on clipping versus coiling

    International Nuclear Information System (INIS)

    Berg, R. van den; Rinkel, G.J.E.; Vandertop, W.P.

    2003-01-01

    Patients with a ruptured intracranial aneurysm should be treated as soon as possible after the haemorrhage to prevent rebleeding and to allow vigorous treatment of ischemic events in case of vasospasm. The choice of treatment, endovascular or surgical, should be based on the angio-architectural aspects of the aneurysm. 3D rotational subtraction angiography will more clearly show the aneurysm morphology and will therefore help in the decision-making process. If an aneurysm is suitable for endovascular treatment ('coiling'), this should be the treatment of first choice, as has been clarified in the ISAT study. Location of the aneurysm only influences the treatment decision in aneurysms located at the basilar artery bifurcation. These aneurysms are preferably treated by endovascular means. The long-term results of endovascular and surgical treatment are still the subject of debate. For both treatment modalities, re-growth of the treated aneurysm has been described, but solid comparative data is missing. In analogy with the ISAT, referral of patients with a ruptured intracranial aneurysm should be performed as soon as possible after the haemorrhage. Preferably, this should be a hospital where neurosurgeons, interventional neuroradiologists, as well as neurologists (with expertise on medical treatment of patients with a subarachnoid haemorrhage) collaborate

  3. Comparison of devices used for stent-assisted coiling of intracranial aneurysms.

    Directory of Open Access Journals (Sweden)

    Benjamin Izar

    Full Text Available INTRODUCTION: Two self-expandable stents, the Neuroform and the Enterprise stent, are widely used for stent-assisted coiling (SAC of complex shaped intracranial aneurysms. However, comparative knowledge about technical feasibility, peri- and post-procedural morbidity and mortality, packing densities as well as follow-up data is limited. MATERIAL AND METHODS: We conducted a retrospective study to investigate differences in aneurysms stented with the Enterprise or Neuroform stents. Angiographic follow-up (mean 19.42 months was available in 72.6% (61/84 of aneurysms treated with stent-assisted coiling. We further sought to compare stent-assisted coiling to a matched patient population with aneurysms treated by conventional coil embolization. RESULTS: The stenting success rate of the Enterprise was higher compared to the Neuroform stent (46/48 and 42/51, respectively. In 5 of 9 cases in which the Neuroform stent was not navigable to the landing zone, we successfully deployed an Enterprise stent instead. Eventually, 42 aneurysms were coiled after stenting in each group. We observed no significant differences in peri-procedural complication rate, post-procedural hospital stay, packing density, recurrence rate or number of in-stent stenosis. Strikingly, 36.1% of followed aneurysms in the SAC group showed progressive occlusion on angiographic follow-up imaging. The packing density was significantly higher in aneurysms treated by SAC as compared to conventionally coiled aneurysms, while recanalization rate was significantly lower in the SAC group. CONCLUSION: The procedural success rate is higher using the Enterprise, but otherwise both stents exhibited similar characteristics. Lower recurrence frequency and complication rates comparable to conventional coil embolization emphasize the importance of stent-assisted coiling in the treatment of complex aneurysms. Progressive occlusion on angiographic follow-up was a distinct and frequent observation in the

  4. Parent artery occlusion for ruptured "true" posterior communicating artery aneurysm.

    Science.gov (United States)

    Mitsuhashi, Takashi; Takeda, Nobuaki; Oishi, Hidenori; Arai, Hajime

    2015-04-01

    A case of a patient with a ruptured true posterior communicating artery (PCoA) aneurysm is reported, who had been managed by early endovascular parent artery occlusion with coils. The small blister aneurysm was located at the proximal PCoA itself and directed superiorly. Postoperative course was uneventful. During 1-month follow-up, the patient recovered well and could care for herself. Aneurysms of the PCoA itself are very rare. As reported to date, surgical procedures would favor microsurgical clipping over endovascular coil embolization. Endovascular treatment may be a good alternative to surgical trapping for true PCoA blister aneurysm. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  5. [False traumatic aneurysm of the ulnar artery in a teenager].

    Science.gov (United States)

    Nour, M; Talha, H; El Idrissi, R; Lahraoui, Y; Ouazzani, L; Oubejja, H; Erraji, M; Zerhouni, H; Ettayebi, F

    2014-12-01

    Most aneurysms of hand arteries are traumatic. It is a generally rare unrecognized pathology. Complications are serious (embolism and thromboses of interdigital arteries). Two main causes can be recalled: acute trauma, with development of a false aneurysm; repeated microtrauma (hand hammer syndrome), with occurrence of an arterial dysplasic aneurysm. The diagnosis is based on the presence of a pulsatile mass, with finger dysesthesia, unilateral Raynaud's phenomenon. It is confirmed by duplex Doppler. Arteriography is necessary but can be replaced by an angio-MR. We report a case of false traumatic aneurysm of the ulnar artery in a teenager. This case illustrates this rare condition and opens discussion on therapeutic options. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  6. Spontaneous dissecting aneurysm of the extracranial vertebral artery (20 cases)

    Energy Technology Data Exchange (ETDEWEB)

    Chiras, J; Marciano, S; Vega Molina, J; Touboul, J; Poirier, B; Bories, J

    1985-07-01

    Spontaneous dissecting aneurysm of the vertebral artery is an infrequent cause of vertebro basilar ischemic strokes. Previously reported cases concern essentially occlusion of the basilar artery. Only 14 cases of spontaneous dissecting aneurysm concern the extracranial vertebral artery among these eight were angiographically documented. In this study based upon 15 patients (20 dissecting aneurysms), the authors discuss etiological factors, such as hypertension or fibromuscular dysplasia: on clinical findings they insist upon the diagnostic value of preliminary symptoms, cervical pain or posterior headaches; the most frequent angiographic appearance was a long and irregular stenosis of one or two segments of the vertebral artery. The prognosis of these aneurysms most often appears favourable in this group.

  7. Inflammatory aneurysms of the abdominal aorta

    International Nuclear Information System (INIS)

    Cilotti, A.; Bagnolesi, P.; Cigoni, R.; Bimbi, M; Bartolozzi, C.

    1991-01-01

    The authors report their experience with US and CT in 31 cases of inflammatory aneurysms out of a study population of 200 patients with abdominal aortic aneurysms. The work started with a case that had not been diagnosed at US, either due to the operator's poor knowledge of this pathologic condition or because of improper examination tecnique. The authors stress the importance of a highfrequency probe and proper gain settings which are often necessary for a good visualization of the anterior aortic wall. The correct diagnosis of the inflammatory nature of the aneurysm has been assessed by US ever since, in all cases except for very obese and meteoric patients. in our series, US diagnostic accuracy was 78% versus 33% reported in literature. US was not accurate in evaluating adjacent structures involvement within fibrous tissues (ureteral narrowing, caval narrowing)-which CT did. Neither US nor CT exhibited reliable diagnostic accuracy in demonstrating enteric involvement within fibrous tissues

  8. "True" posterior communicating aneurysms: Three cases, three strategies.

    Science.gov (United States)

    Nery, Breno; Araujo, Ricardo; Burjaili, Bruno; Smith, Timothy R; Rodrigues, Jose Carlos; Silva, Marcelo Nery

    2016-01-01

    The authors provide a review of true aneurysms of the posterior communicating artery (PCoA). Three cases admitted in our hospital are presented and discussed as follows. First patient is a 51-year-old female presenting with a Fisher II, Hunt-Hess III (headache and confusion) subarachnoid hemorrhage (SAH) from a ruptured true aneurysm of the right PCoA. She underwent a successful ipsilateral pterional craniotomy for aneurysm clipping and was discharged on postoperative day 4 without neurological deficit. Second patient is a 53-year-old female with a Fisher I, Hunt-Hess III (headache, mild hemiparesis) SAH and multiple aneurisms, one from left ophthalmic carotid artery and one (true) from right PCoA. These lesions were approached and successfully treated by a single pterional craniotomy on the left side. The patient was discharged 4 days after surgery, with complete recovery of muscle strength during follow-up. Third patient is a 69-year-old male with a Fisher III, Hunt-Hess III (headache and confusion) SAH, from a true PCoA on the right. He had a left subclavian artery occlusion with flow theft from the right vertebral artery to the left vertebral artery. The patient underwent endovascular treatment with angioplasty and stent placement on the left subclavian artery that resulted in aneurysm occlusion. In conclusion, despite their seldom occurrence, true PCoA aneurysms can be successfully treated with different strategies.

  9. Multiple intracranial aneurysms following radiation therapy for pituitary adenoma. Case report

    Energy Technology Data Exchange (ETDEWEB)

    Nishi, Tohru; Matsukado, Yasuhiko; Kodama, Takafumi; Hiraki, Toshiro

    1987-03-01

    A 57-year-old man was admitted because of visual disturbance due to a recurrent pituitary adenoma. Nine years ago craniotomy was performed for the chromophobe adenoma and postoperative radiation therapy was applied with tumor dose of 50 Gy. Digital subtraction angiography indicated existence of an aneurysm at the carotid bifurcation and the finding was confirmed by conventional angiography, which revealed a saccular aneurysm and irregularity of the carotid walls. In surgery there were not only the saccular aneurysm found in the angiogram, but also three other fusiform aneurysms and severe sclerotic change at the major arteries adjoining the sellar region. Azzarelli et al. reported a fatal case due to the development of arteriosclerotic intracranial fusiform aneurysms following radiation therapy for suprasellar germinoma. This case is the second case which indicates the development of intracranial aneurysm following radiation therapy. Emphasis is placed on careful follow-up examination for radiated pituitary adenoma with computed tomography, digital subtraction angiography, or occasionally conventional angiography, even though the postoperative condition of the primary lesion is stabilized.

  10. Cellular responses of bioabsorbable polymeric material and Guglielmi detachable coil in experimental aneurysms.

    Science.gov (United States)

    Murayama, Yuichi; Viñuela, Fernando; Tateshima, Satoshi; Gonzalez, Nestor R; Song, Joon K; Mahdavieh, Haleh; Iruela-Arispe, Luisa

    2002-04-01

    Acceleration of healing mechanisms is a promising approach to improve current limitations of endovascular aneurysm therapy with the use of platinum coils. We evaluated a new endovascular therapeutic, bioabsorbable polymeric material (BPM), which may promote cellular reaction in the aneurysms. Four different concentrations of lactide/glycolic acid copolymer [poly(D-L-lactic-co-glycolic acid)] (PLGA), 85/15, 75/25, 65/35, and 50/50, were used as BPMs. Sixteen experimental aneurysms were created in 8 swine. Eight-millimeter-long spiral-shaped BPMs were surgically implanted in the aneurysms without tight packing (n=3 for each BPM). Guglielmi detachable coils (GDCs) were used as control (n=4). The animals were killed 14 days after embolization, and angiographic, histological, and immunohistochemical analyses were performed. Despite loose packing of aneurysms with BPMs, faster BPMs such as 50/50 or 65/35 PLGA demonstrated more mature collagen formation and fibrosis in the sac and neck of the aneurysm. One aneurysm treated with 65/35 PLGA, 1 treated with 75/25 PLGA, and all 3 treated with 85/15 PLGA showed a neck remnant on angiography. There was a linear relationship between collagen levels and polymer degradation properties (r=-0.9513). This preliminary animal study indicates that acceleration of aneurysm healing with the use of BPM is feasible. This concept can be applied to decrease and perhaps prevent aneurysmal recanalization after endovascular treatment of cerebral aneurysms.

  11. Wall enhancement on high-resolution magnetic resonance imaging may predict an unsteady state of an intracranial saccular aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Peng; Zhang, Hong-Qi [Capital Medical University, Department of Neurosurgery, Xuanwu Hospital, Beijing (China); Yang, Qi [Capital Medical University, Department of Radiology, Xuanwu Hospital, Beijing (China); Wang, Dan-Dan [Capital Medical University, Department of Clinical Pathology, Xuanwu Hospital, Beijing (China); Guan, Shao-Chen [Capital Medical University, Department of Evidence-Based Medicine, Xuanwu Hospital, Beijing (China)

    2016-10-15

    The aneurysm wall has been reported to play a critical role in the formation, development, and even rupture of an aneurysm. We used high-resolution magnetic resonance imaging (HRMRI) to investigate the aneurysm wall in an effort to identify evidence of inflammation invasion and define its relationship with aneurysm behavior. Patients with intracranial aneurysms who were prospectively evaluated using HRMRI between July 2013 and June 2014 were enrolled in this study. The aneurysm's wall enhancement and evidence of inflammation invasion were determined. In addition, the relationship between aneurysm wall enhancement and aneurysm size and symptoms, including ruptured aneurysms, giant unruptured intracranial aneurysms (UIAs) presenting as mass effect, progressively growing aneurysms, and aneurysms associated with neurological symptoms, was statistically analyzed. Twenty-five patients with 30 aneurysms were available for the current study. Fourteen aneurysms showed wall enhancement, including 6 ruptured and 8 unruptured aneurysms. Evidence of inflammation was identified directly through histological studies and indirectly through intraoperative investigations and clinical courses. The statistical analysis indicated no significant correlation between aneurysm wall enhancement and aneurysm size. However, there was a strong correlation between wall enhancement and aneurysm symptoms, with a kappa value of 0.86 (95 % CI 0.68-1). Aneurysm wall enhancement on HRMRI might be a sign of inflammatory change. Symptomatic aneurysms exhibited wall enhancement on HRMRI. Wall enhancement had a high consistent correlation of symptomatic aneurysms. Therefore, wall enhancement on HRMRI might predict an unsteady state of an intracranial saccular aneurysm. (orig.)

  12. Treatment of anterior communicating artery aneurysms with Guglielmi detachable coils

    International Nuclear Information System (INIS)

    Xu Yi; Liu Jianmin; Hong Bo; Zhao Wenyuan; Huang Qinghai; Zhang Xin; Zhang Long

    2003-01-01

    Objective: To summarize the experience on endovascular treatment of anterior communicating artery aneurysms with Guglielmi detachable coils (GDCs) in 262 cases. Methods: All aneurysms were embolized with GDCs. Catheterization at both ICA was used to monitor the patency of parent arteries for patients with well-developed A1 segment of both ACAs. Microcatheter-assisted or microwire-assisted technique was undertaken to keep patency of parent arteries if the aneurysmal neck was involved with A2 segment. Thirty-four cases with multiple aneurysms had been treated successfully only in one session. Results: Complete embolization was achieved in 160 cases, while subtotal in 56 (>90%) and partial in 46 (<90%). Occlusion of parent arteries developed in 10 cases because of over-occlusion, and cerebral infarction was found in 16 cases after the procedure. Three cases with procedure-related thrombosis were revascularized by urokinase profusion. Follow-up angiograms of 3-6 months showed recanalization in 8 cases requiring a second time session. One case of recurrent aneurysm after GDC treatment was cured by surgical clipping. Conclusions: The result of endovascular treatment of anterior communicating artery aneurysms is fruitful and seems to be an alternative method in improving the rate of occlusion and reducing the cerebral infarction

  13. Inflammation and intracranial aneurysms: mechanisms of initiation, growth, and rupture

    Directory of Open Access Journals (Sweden)

    Peter S Amenta

    2015-06-01

    Full Text Available Outcomes following aneurysmal subarachnoid hemorrhage remain poor in many patients, despite advances in microsurgical and endovascular management. Consequently, considerable effort has been placed in determining the mechanisms of aneurysm formation, growth, and rupture. Various environmental and genetic factors are implicated as key components in the aneurysm pathogenesis. Currently, sufficient evidence exists to incriminate the inflammatory response as the common pathway leading to aneurysm generation and rupture. Central to this model is the interaction between the vessel wall and inflammatory cells. Dysfunction of the endothelium and vascular smooth muscle cells (VSMCs promotes a chronic pathological inflammatory response that progressively weakens the vessel wall. We review the literature pertaining to the cellular and chemical mechanisms of inflammation that contribute to aneurysm development. Hemodynamic stress and alterations in blood flow are discussed regarding their role in promoting chronic inflammation. Endothelial cell and VSMC dysfunction are examined concerning vascular remodeling. The contribution of inflammatory cytokines, especially tumor necrosis factor-α is illustrated. Inflammatory cell infiltration, particularly macrophage-mediated deterioration of vascular integrity, is reviewed. We discuss the inflammation as a means to determine aneurysms at greatest risk of rupture. Finally, future therapeutic implications of pharmacologic modulation of the inflammation are discussed.

  14. Predictors of residual flow in embolized intracranial ruptured aneurysms at early follow-up.

    Science.gov (United States)

    Serafin, Zbigniew; Strześniewski, Piotr; Beuth, Wojciech

    2014-01-01

    The possibility of recanalization and the need for retreatment are the most important drawbacks of intracranial aneurysm embolization. The purpose of the study was to prospectively analyze the results of early follow-up angiography of embolized ruptured aneurysms in an attempt to determine factors predicting the presence of residual flow. Evaluation included 72 patients with 72 aneurysms, which were followed-up 3 months after the treatment. Analysis of residual flow predictors included: age and gender, clinical state in Hunt-Hess scale, aneurysm localization, aneurysm three dimensions and volume, neck width, sac-to-neck ratio, initial result of embolization, number of coils used and the use of hydrogel coils and stents. Mean sac diameter was 6.5±3.9 mm, and mean neck width was 2.9±1.4 mm. Follow-up angiography presented residual flow in 26 aneurysms (36.1%): class 2 in 8 aneurysms (11.1%), and class 3 in 18 cases (25.0%). Stable aneurysm filling was observed in 45 cases (62.5%), progression of residual flow in 25 cases (34.7%), and regression in 2 cases (2.8%). According to ROC analysis independent predictors of residual flow were aneurysm neck diameter (AUC 0.857, 95% CI: 0.755-0.928, p<0.0001) and sac-to-neck ratio (AUC 0.817, 95% CI: 0.708-0.898, p<0.0001). Cut-off point of the ROC curve was established at 2.8 mm for neck diameter, and 1.73 for sac-to-neck ratio. Aneurysm neck diameter and sac-to-neck ratio are independently related to the residual flow in embolized ruptured aneurysms at early follow-up.

  15. Three dimensional CT angiography (3D-CTA) in ruptured aneurysm surgery on acute stage

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Endo, Yuji; Nakano, Masayuki

    1998-01-01

    We evaluated three-dimensional CT angiography (3D-CTA) for the treatment of acutely ruptured cerebral aneurysms. Sixty patients with subarachnoid hemorrhage from cerebral aneurysms were investigated both by 3D-CTA and conventional angiography and 26 patients were studied using 3D-CTA without conventional angiography. In the 60 cases, both 3D-CTA and the conventional angiography revealed 100% accuracy in diagnosing ruptured aneurysms, and 3D-CTA and the conventional angiography showed 96% and 92% accuracy for unruptured aneurysms respectively. 3D-CTA was equal or superior to the conventional angiography. Based on these data, since December, 1996, we have operated on 26 consecutive patients with ruptured aneurysms located in the anterior circulation of the circle of Willis, using 3D-CTA without conventional angiography. Thirty-one aneurysms, including 5 associated unruptured aneurysms, were visualized by 3D-CTA and verified at surgery. All aneurysms were clipped successfully. We think that it will be possible to operate on most ruptured aneurysms using only 3D-CTA without the conventional angiography except for the cases of the following situations: if a cerebral infarction is present, conventional angiography is required to evaluate for a stenotic or occlusive lesion of the intracranial arteries, cervical carotid, or vertebral arteries; in cases of giant or large aneurysms, the dynamic information provided by the conventional angiography is needed in case bypass surgery is necessary; and for aneurysms close to bony structures, such as an internal carotid-ophthalmic artery aneurysm, conventional angiography is necessary. (author)

  16. Case Series of Ruptured Jamaican Berry Aneurysms Four Decades ...

    African Journals Online (AJOL)

    Having bled, the aneurysms exposed themselves by causing sudden severe headaches, and various neurological problems, depending on their locations. We found more females than males. The posterior communicating artery aneurysm was predominant. There were no cerebro-vascular spasms postoperatively.

  17. Non-coronary sinus of Valsalva aneurysm diagnosed after a road traffic accident

    OpenAIRE

    Ribeiro, A; Fernandes, F; Costeira, A; Simões, A; Rodrigues, P

    1999-01-01

    A 38 year old man with a huge unruptured sinus of Valsalva aneurysm, complicated with severe valvar aortic regurgitation, is described. The aneurysm was detected by echocardiography in the asymptomatic patient who presented with an intense precordial diastolic rumble after a road traffic accident. The patient had successful surgery for the aneurysm and aortic valve replacement. Possible aetiologies for the aneurysm and a brief revision of clinical aspects and treatment are discussed.


Keywor...

  18. Temporo-sylvian anastomosis and aneurysm clipping in a case of left M1 aneurysm with progressive evolution after initial embolization; Case report

    Directory of Open Access Journals (Sweden)

    Ion Georgiana

    2015-06-01

    Full Text Available A giant unrupted middle cerebral artery aneurysm partially thrombosed, previously endovascularly treated after a mild right hemiparesis remitted. After 12 months, in routine check we discovered a reperfusion of the aneurysm and decide ECIC bypass and clipping, with a good outcome

  19. Aortocaval fistula (ACF) in patients operated for ruptured aortic aneurysm (rAAA)

    DEFF Research Database (Denmark)

    Warning, Karina; Houlind, Kim Christian; Ravn, Hans

    Aortocaval fistula (ACF) in patients operated for Ruptured Acute Aorta Aneurysm (rAAA): A surgical challenge. Introduction Aortocaval fistula is a rare complication of abdominal aortic aneurysm (AAA). It been reported to be present in less than 1% of all AAAs. ACF arise in patients with large...... aneurysms and is typically discovered peroperatively in patients with rAAA. Open surgical treatment is associated with high mortality and morbidity. ACF is a result of spontaneously rupture of large atherosclerotic aneurysms into the inferior vena cava in 80%, 15% arise after trauma and 5% are iatrogenic....... Patients During the last 9 month, we have operated three cases with rAAA and ACF. All patients had an open, acute operation. All ACFs detected during operation. Common for all operations was that the patients had large aneurysms (>10 cm) and extensive bleeding (3-4 l) immediately when the aneurysm...

  20. Early experience with the multilayer aneurysm repair stent in the endovascular treatment of trans/infragenicular popliteal artery aneurysms: a mixed bag.

    Science.gov (United States)

    Thakar, Tejal; Chaudhuri, Arindam

    2013-06-01

    To present a preliminary experience using a multilayer flow-modulating stent for trans/infragenicular popliteal endovascular aneurysm repair. Five men (mean age 76 years, range 62-86) with 6 popliteal artery aneurysms (PAAs) measuring 22 to 39 mm in diameter (mean 30) underwent endovascular repair using the Cardiatis Multilayer Aneurysm Repair System (MARS) between June and August 2011. Radiological assessments post procedure using duplex ultrasonography and biplanar knee radiographs (additional contrast studies as necessary) sought evidence of aneurysm exclusion, graft patency, and preservation of branches and runoff vessels. Technical success was achieved in each case. There was one symptomatic stent occlusion requiring thrombectomy at 4 days, with reocclusion, and one leak via the stent struts into the sac with no branch outflow identified. Two further symptomatic stent occlusions were identified within a 6-week follow-up period, totaling 3 occlusions among the 6 devices deployed. No firm conclusion can be reached on the efficacy of the MARS in PAAs due to the inherent limitations of this small series, although a 50% thrombosis rate is a poor outcome. The risk of early thrombosis in flow-modulating stents deployed in the popliteal artery exists, as it does with earlier generation stent-grafts. Larger prospective trials and the influence of more aggressive antithrombotic/anticoagulant therapy should be considered to enable accurate evaluation of this device in popliteal artery aneurysms.

  1. 3D printing of an aortic aneurysm to facilitate decision making and device selection for endovascular aneurysm repair in complex neck anatomy.

    Science.gov (United States)

    Tam, Matthew D B S; Laycock, Stephen D; Brown, James R I; Jakeways, Matthew

    2013-12-01

    To describe rapid prototyping or 3-dimensional (3D) printing of aneurysms with complex neck anatomy to facilitate endovascular aneurysm repair (EVAR). A 75-year-old man had a 6.6-cm infrarenal aortic aneurysm that appeared on computed tomographic angiography to have a sharp neck angulation of ~90°. However, although the computed tomography (CT) data were analyzed using centerline of flow, the true neck length and relations of the ostial origins were difficult to determine. No multidisciplinary consensus could be reached as to which stent-graft to use owing to these borderline features of the neck anatomy. Based on past experience with rapid prototyping technology, a decision was taken to print a model of the aneurysm to aid in visualization of the neck anatomy. The CT data were segmented, processed, and converted into a stereolithographic format representing the lumen as a 3D volume, from which a full-sized replica was printed within 24 hours. The model demonstrated that the neck was adequate for stent-graft repair using the Aorfix device. Rapid prototyping of aortic aneurysms is feasible and can aid decision making and device delivery. Further work is required to test the value of 3D replicas in planning procedures and their impact on procedure time, radiation dose, and procedure cost.

  2. Intracranial infective aneurysms presenting with haemorrhage: An analysis of angiographic findings, management and outcome

    International Nuclear Information System (INIS)

    Venkatesh, Sudhakar K.; Phadke, Rajendra V.; Kalode, Ravi R.; Kumar, Sunil; Jain, Vijendra K.

    2000-01-01

    AIM: This study is an analysis of angiographic findings in 17 patients with infective aneurysms who presented with intracranial haemorrhage and reviews the management and outcome in the context of the existing literature. MATERIALS AND METHODS: A retrospective study of infective aneurysms in 17 patients was carried out. Cranial angiography was performed in all patients. The location, size and outline of aneurysms were analysed. Ten patients were managed conservatively and six patients underwent surgery for the ruptured infective aneurysms and were followed up for a period of 35.8 months and 23 months, respectively. RESULTS: Twenty-two aneurysms were identified (five unruptured) in 17 patients. Twenty aneurysms (90.9%) were distal in location and two (9.1%) proximal. Sixty percent were in the posterior circulation with 55% in the posterior cerebral artery (PCA) territory, 27.3% in the middle cerebral artery (MCA) territory and 9.1% in the anterior cerebral artery (ACA) territory. Fourteen aneurysms were small (3-5 mm) and eight were medium sized (6-9 mm). 72.7% of aneurysms had irregular outline and 27.3% regular outline. Out of the 10 ruptured aneurysms managed conservatively, eight resolved. One patient died, presumably due to rebleed, and one had infarction due to parent vessel thrombosis. Six aneurysms were surgically managed with good results. Of the five unruptured aneurysms one was surgically managed and the remaining four conservatively managed patients did not bleed during follow-up. CONCLUSION: Patients with ruptured infective aneurysms fared well with medical management and the outcome in this series is better than that reported in literature. Patients on conservative management, however, need closer monitoring with angiographic follow-up. Active management is required with enlarging or persisting aneurysms. Venkatesh, S.K. (2000)

  3. A study of the hemodynamics of anterior communicating artery aneurysms

    Science.gov (United States)

    Cebral, Juan R.; Castro, Marcelo A.; Putman, Christopher M.

    2006-03-01

    In this study, the effects of unequal physiologic flow conditions in the internal carotid arteries on the intra-aneurysmal hemodynamics of anterior communicating artery aneurysms were investigated. Patient-specific vascular computational fluid dynamics models of five cerebral aneurysms were constructed from bilateral 3D rotational angiography images. The aneurysmal hemodynamics was analyzed under a range of physiologic flow conditions including the effects of unequal mean flows and phase shifts between the flow waveforms of the left and right internal carotid arteries. A total of five simulations were performed for each patient, and unsteady wall shear stress (WSS) maps were created for each flow condition. Time dependent curves of average WSS magnitude over selected regions on the aneurysms were constructed and used to analyze the influence of the inflow conditions. It was found that mean flow imbalances in the feeding vessels tend to shift the regions of elevated WSS (flow impingement region) towards the dominating inflow jet and to change the magnitude of the WSS peaks. However, the overall qualitative appearance of the WSS distribution and velocity simulations is not substantially affected. In contrast, phase differences tend to increase the temporal complexity of the hemodynamic patterns and to destabilize the intra-aneurysmal flow pattern. However, these effects are less important when the A1 confluence is less symmetric, i.e. dominated by one of the A1 segments. Conditions affecting the flow characteristics in the parent arteries of cerebral aneurysms with more than one avenue of inflow should be incorporated into flow models.

  4. Circumferential and fusiform intracranial aneurysms: reconstructive endovascular treatment with self-expandable stents

    Energy Technology Data Exchange (ETDEWEB)

    Lubicz, Boris [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Hopital Erasme, Service de Radiologie (EA 2691), Brussels (Belgium); Collignon, Laurent; Baleriaux, Danielle [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Lefranc, Florence; Bruneau, Michael; Brotchi, Jacques; Witte, Olivier de [Erasme University Hospital, Department of Neurosurgery, Brussels (Belgium)

    2008-06-15

    We report our experience with endovascular treatment (EVT) of circumferential and fusiform intracranial aneurysms by a reconstructive approach with self-expandable stents. A retrospective review of our prospectively maintained database identified all circumferential and fusiform aneurysms treated by a reconstructive endovascular approach over a 3-year period. Clinical charts, procedural data, and angiographic results were reviewed. From April 2004 to May 2007, 13 patients were identified, of whom 12 were asymptomatic and 1 presented with a subarachnoid hemorrhage. Two patients with an aneurysm {<=}2 mm were treated by stent-within-stent placement without coiling (group 1). In 11 patients with a larger aneurysm, stenting with subsequent coiling was performed (group 2). In this latter approach, a balloon was temporarily inflated within the stent to ensure safe coil delivery. All patients showed an excellent clinical outcome. Asymptomatic procedural complications occurred in three patients, two with cervical internal carotid artery dissection and one with retroperitoneal hematoma. In patients of group 1, the aneurysm had completely disappeared at 6 months. In patients of group 2, aneurysm occlusion was complete in three and incomplete in eight. Follow-up angiography in 12 patients showed four with further thrombosis, six with stable results, and two with minor recanalization. Circumferential and fusiform intracranial aneurysms may be treated by a reconstructive endovascular approach with self-expandable stents. In small aneurysms, a stent-within-stent technique is effective, whereas stenting and subsequent coiling is indicated in larger aneurysms. This therapeutic protocol is associated with good clinical and anatomical results. (orig.)

  5. Parent artery occlusion for ruptured “true” posterior communicating artery aneurysm

    Science.gov (United States)

    Takeda, Nobuaki; Oishi, Hidenori; Arai, Hajime

    2015-01-01

    A case of a patient with a ruptured true posterior communicating artery (PCoA) aneurysm is reported, who had been managed by early endovascular parent artery occlusion with coils. The small blister aneurysm was located at the proximal PCoA itself and directed superiorly. Postoperative course was uneventful. During 1-month follow-up, the patient recovered well and could care for herself. Aneurysms of the PCoA itself are very rare. As reported to date, surgical procedures would favor microsurgical clipping over endovascular coil embolization. Endovascular treatment may be a good alternative to surgical trapping for true PCoA blister aneurysm. PMID:25953771

  6. Treatment Challenges of a Primary Vertebral Artery Aneurysm Causing Recurrent Ischemic Strokes

    Directory of Open Access Journals (Sweden)

    Davide Strambo

    2017-01-01

    Full Text Available Background. Extracranial vertebral artery aneurysms are a rare cause of embolic stroke; surgical and endovascular therapy options are debated and long-term complication may occur. Case Report. A 53-year-old man affected by neurofibromatosis type 1 (NF1 came to our attention for recurrent vertebrobasilar embolic strokes, caused by a primary giant, partially thrombosed, fusiform aneurysm of the left extracranial vertebral artery. The aneurysm was treated by endovascular approach through deposition of Guglielmi Detachable Coils in the proximal segment of the left vertebral artery. Six years later the patient presented stroke recurrence. Cerebral angiography and Color Doppler Ultrasound well characterized the unique hemodynamic condition developed over the years responsible for the new embolic event: the aneurysm had been revascularized from its distal portion by reverse blood flow coming from the patent vertebrobasilar axis. A biphasic Doppler signal in the left vertebral artery revealed a peculiar behavior of the blood flow, alternately directed to the aneurysm and backwards to the basilar artery. Surgical ligation of the distal left vertebral artery and excision of the aneurysm were thus performed. Conclusion. This is the first described case of NF1-associated extracranial vertebral artery aneurysm presenting with recurrent embolic stroke. Complete exclusion of the aneurysm from the blood circulation is advisable to achieve full resolution of the embolic source.

  7. Middle and long-term follow-up of intracranial aneurysms treated with Matrix detachable coils

    International Nuclear Information System (INIS)

    Wu Xi; Liu Jianmin; Huang Qinghai; Xu Yi

    2008-01-01

    Objective: This study was undertaken to evaluate the safety of the polyglycolic/polylactic acid (PGLA)-coated Matrix detachable coils (Matrix) and analyze factors which may relate to the recanalization rate of the Matrix coils in the treatment of intracranial aneurysms. Methods: 75 patients underwent 79 aneurysm treatments with Matrix coils from May 2003 to July 2005 were retrospectively investigated. Morphological changes were compared postoperatively with last-follow-up digital subtraction angiography (DSA) by using the Raymond scale. We defined incomplete recanalization or stable aneurysms as uncured, while those of progressive occlusion or complete occlusion aneurysms demonstrated on the last-follow-up imagings as cured. We also utilized Cox model for analyzing the relationships between factors including age, gender, degree of aneurysmal occlusion, stenting, aneurysm neck size, aneurysm maximum size and Matrix coils length (%) and the long-term angiographic follow-up results. Results: The correlative surgical complications rate with Matrix coils was 13.3%. The total rate of recanalization was 11.4%. Large aneurysms treated with combined stenting got 40% recanalization. No statistic relationships were shown between the factors forementioned and the recanalization rate, but progressive occlusion was observed in 11 (61%)incompletely treated aneurysms. Conclusions: Matrix detachable coil technique is safe for intracranial aneurysm and would further decrease the recurrence of large aneurysm with combination of stenting but long term efficacy needs further follow-up and large scale randomized control study. (authors)

  8. Internal Carotid Artery Aneurysms Presenting with Epistaxis - Our Experience and Review of Literature.

    Science.gov (United States)

    Garg, Kanwaljeet; Gurjar, Hitesh Kumar; Singh, Pankaj Kumar; Singh, Manmohan; Chandra, P Sarat; Sharma, Bhawani Shankar

    Intracranial internal carotid artery aneurysms are an extremely rare cause of spontaneous epistaxis, with a few documented cases. The management of such cases is challenging due to the relative anatomical inaccessibility of the bleeding point. The aim of the present study was to acquaint the readers with this rare type of aneurysm presenting with epistaxis and to report our experience of treating cases of severe epistaxis due to internal carotid artery (ICA) aneurysms. Data of 4 patients with İCA aneurysms presenting with epistaxis from June 2011 to July 2013 was retrospectively reviewed. The age of patients ranged from 16 to 62 years. Duration of epistaxis ranged from 3 months to 3 years. Two patients had severe epistaxis following transnasal biopsy. Two patients had a history of trauma. Two patients developed hemodynamically instability. All the patients were managed with trapping of the aneurysm. Complete exclusion of aneurysm from circulation was achieved in all the patients. ICA aneurysms can rarely present as life-endangering epistaxis. In patients presenting with a history of craniocerebral trauma, traumatic pseudoaneurysm must be considered as a differential diagnosis. Trapping of the aneurysm is a good option if there is good cross circulation.

  9. Distal posterior cerebral artery aneurysms: Retrospective review of characteristics and endovascular treatment

    International Nuclear Information System (INIS)

    Baek, Jin Wook; Jeong, Bae Woong; Seung, Won Bae

    2016-01-01

    The objective of this study was to review the clinical outcome after treatment of distal posterior cerebral artery (PCA) aneurysms via endovascular approach. Eleven patients with 11 distal PCA aneurysms who were treated via endovascular approach in Inje University Busan Paik Hospital and Kosin University Gospel Hospital from December 2002 to December 2013 were retrospectively reviewed. Among the 11 patients, there were 3 males (27.3%) and 8 females (72.7%). The mean age was 56.6 years (range 44 -72 years) and the mean aneurysm size was 8.45 mm (3 - 30 mm). Four (36.4%) aneurysms were located in the P2 segment, 6 (54.5%) in the P3 segment and 1 (9.1%) in the P1/2 junction. Seven (63.6%) aneurysms were treated with preservation of the parent artery; and the remaining 4 (36.4%) aneurysms were treated with parent artery occlusion. After treatment, the overall complication rate was 27% with the morbidity rate of 9.1% and the mortality rate of 18%. Endovascular treatment of distal PCA aneurysm might be used to minimize neurologic deficit, considering the diverse and rich collaterals of posterior cerebral artery

  10. Mycotic aneurysm in a turtle hunter: brief review and a case report

    Directory of Open Access Journals (Sweden)

    Harsha Moole

    2015-06-01

    Full Text Available Salmonella-associated mycotic aneurysm is a rare, but dreaded, complication of salmonellosis. Immunocompromised and elderly populations are more susceptible to develop this extra-intestinal complication. Salmonella is spread via fecal–oral and vehicle-borne routes. Reptiles, especially small pet turtles, have been linked with an increased risk of Salmonella infection. Diagnosis of mycotic aneurysm is a challenge due to atypical presentations. Recently, widespread use of CT scan imaging to evaluate for unexplained abdominal pain and sepsis has led to early identification of mycotic aneurysms. Antibiotic therapy and surgical intervention are the cornerstones of management. Open surgery has been the gold standard of treatment but is associated with increased morbidity and mortality. A relatively new alternative to open surgery is endovascular aneurysm repair (EVAR. It is comparatively less invasive and is associated with reduced early morbidity and mortality in the setting of mycotic aneurysm. However, there is a risk of late infection. Here, we present a patient with Salmonella mycotic aneurysm initially treated conservatively with antibiotic therapy who later underwent successful interval EVAR with no complications to date. Also included is a brief review of Salmonella-associated mycotic aneurysms.

  11. Distal posterior cerebral artery aneurysms: Retrospective review of characteristics and endovascular treatment

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jin Wook [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Jeong, Bae Woong [Dept. of Diagnostic Radiology, Inje University College of Medicine, Busan Paik Hospital, Busan (Korea, Republic of); Seung, Won Bae [Dept. of Neurosurgery, Kosin University College of Medicine, Gospel Hospital, Busan (Korea, Republic of)

    2016-04-15

    The objective of this study was to review the clinical outcome after treatment of distal posterior cerebral artery (PCA) aneurysms via endovascular approach. Eleven patients with 11 distal PCA aneurysms who were treated via endovascular approach in Inje University Busan Paik Hospital and Kosin University Gospel Hospital from December 2002 to December 2013 were retrospectively reviewed. Among the 11 patients, there were 3 males (27.3%) and 8 females (72.7%). The mean age was 56.6 years (range 44 -72 years) and the mean aneurysm size was 8.45 mm (3 - 30 mm). Four (36.4%) aneurysms were located in the P2 segment, 6 (54.5%) in the P3 segment and 1 (9.1%) in the P1/2 junction. Seven (63.6%) aneurysms were treated with preservation of the parent artery; and the remaining 4 (36.4%) aneurysms were treated with parent artery occlusion. After treatment, the overall complication rate was 27% with the morbidity rate of 9.1% and the mortality rate of 18%. Endovascular treatment of distal PCA aneurysm might be used to minimize neurologic deficit, considering the diverse and rich collaterals of posterior cerebral artery.

  12. Physiological remodeling of bifurcation aneurysms: preclinical results of the eCLIPs device.

    Science.gov (United States)

    Marotta, Thomas R; Riina, Howard A; McDougall, Ian; Ricci, Donald R; Killer-Oberpfalzer, Monika

    2018-02-01

    OBJECTIVE Intracranial bifurcation aneurysms are complex lesions for which current therapy, including simple coiling, balloon- or stent-assisted coiling, coil retention, or intrasaccular devices, is inadequate. Thromboembolic complications due to a large burden of intraluminal metal, impedance of access to side branches, and a high recurrence rate, due largely to the unmitigated high-pressure flow into the aneurysm (water hammer effect), are among the limitations imposed by current therapy. The authors describe herein a novel device, eCLIPs, and its use in a preclinical laboratory study that suggests the device's design and functional features may overcome many of these limitations. METHODS A preclinical model of wide-necked bifurcation aneurysms in rabbits was used to assess functional features and efficacy of aneurysm occlusion by the eCLIPs device. RESULTS The eCLIPs device, in bridging the aneurysm neck, allows coil retention, disrupts flow away from the aneurysm, leaves the main vessel and side branches unencumbered by intraluminal metal, and serves as a platform for endothelial growth across the neck, excluding the aneurysm from the circulation. CONCLUSIONS The eCLIPs device permits physiological remodeling of the bifurcation.

  13. The effect of inlet waveforms on computational hemodynamics of patient-specific intracranial aneurysms.

    Science.gov (United States)

    Xiang, J; Siddiqui, A H; Meng, H

    2014-12-18

    Due to the lack of patient-specific inlet flow waveform measurements, most computational fluid dynamics (CFD) simulations of intracranial aneurysms usually employ waveforms that are not patient-specific as inlet boundary conditions for the computational model. The current study examined how this assumption affects the predicted hemodynamics in patient-specific aneurysm geometries. We examined wall shear stress (WSS) and oscillatory shear index (OSI), the two most widely studied hemodynamic quantities that have been shown to predict aneurysm rupture, as well as maximal WSS (MWSS), energy loss (EL) and pressure loss coefficient (PLc). Sixteen pulsatile CFD simulations were carried out on four typical saccular aneurysms using 4 different waveforms and an identical inflow rate as inlet boundary conditions. Our results demonstrated that under the same mean inflow rate, different waveforms produced almost identical WSS distributions and WSS magnitudes, similar OSI distributions but drastically different OSI magnitudes. The OSI magnitude is correlated with the pulsatility index of the waveform. Furthermore, there is a linear relationship between aneurysm-averaged OSI values calculated from one waveform and those calculated from another waveform. In addition, different waveforms produced similar MWSS, EL and PLc in each aneurysm. In conclusion, inlet waveform has minimal effects on WSS, OSI distribution, MWSS, EL and PLc and a strong effect on OSI magnitude, but aneurysm-averaged OSI from different waveforms has a strong linear correlation with each other across different aneurysms, indicating that for the same aneurysm cohort, different waveforms can consistently stratify (rank) OSI of aneurysms. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Oculomotor nerve palsy by posterior communicating artery aneurysms: influence of surgical strategy on recovery.

    Science.gov (United States)

    Güresir, Erdem; Schuss, Patrick; Seifert, Volker; Vatter, Hartmut

    2012-11-01

    Resolution of oculomotor nerve palsy (ONP) after clipping of posterior communicating artery (PCoA) aneurysms has been well documented. However, whether additional decompression of the oculomotor nerve via aneurysm sac dissection or resection is superior to pure aneurysm clipping is the subject of much debate. Therefore, the objective in the present investigation was to analyze the influence of surgical strategy--specifically, clipping with or without aneurysm dissection--on ONP resolution. Between June 1999 and December 2010, 18 consecutive patients with ruptured and unruptured PCoA aneurysms causing ONP were treated at the authors' institution. Oculomotor nerve palsy was evaluated on admission and at follow-up. The electronic database MEDLINE was searched for additional data in published studies of PCoA aneurysms causing ONP. Two reviewers independently extracted data. Overall, 8 studies from the literature review and 6 patients in the current series (121 PCoA aneurysms) met the study inclusion criteria. Ninety-four aneurysms were treated with simple aneurysm neck clipping and 27 with clipping plus aneurysm sac decompression. The surgical strategy, simple aneurysm neck clipping versus clipping plus oculomotor nerve decompression, had no effect on full ONP resolution on univariate (p = 0.5) and multivariate analyses. On multivariate analysis, patients with incomplete ONP at admission were more likely to have full resolution of the palsy than were those with complete ONP at admission (p = 0.03, OR = 4.2, 95% CI 1.1-16). Data in the present study indicated that ONP caused by PCoA aneurysms improves after clipping without and with oculomotor nerve decompression. The resolution of ONP is inversely associated with the initial severity of ONP.

  15. Brain Aneurysm: Recovery

    Science.gov (United States)

    ... people, but they are growing larger as medical technology continues to grow and early detection and treatment becomes more prevalent. Read More “I’ve met many people through The Brain Aneurysm Foundation. Each one with their own unique story. Of survival, of appreciation for what we still ...

  16. A computer-simulated liver phantom (virtual liver phantom) for multidetector computed tomography evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Funama, Yoshinori [Kumamoto University, Department of Radiological Sciences, School of Health Sciences, Kumamoto (Japan); Awai, Kazuo; Nakayama, Yoshiharu; Liu, Da; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto (Japan); Miyazaki, Osamu; Goto, Taiga [Hitachi Medical Corporation, Tokyo (Japan); Hori, Shinichi [Gate Tower Institute of Image Guided Therapy, Osaka (Japan)

    2006-04-15

    The purpose of study was to develop a computer-simulated liver phantom for hepatic CT studies. A computer-simulated liver phantom was mathematically constructed on a computer workstation. The computer-simulated phantom was calibrated using real CT images acquired by an actual four-detector CT. We added an inhomogeneous texture to the simulated liver by referring to CT images of chronically damaged human livers. The mean CT number of the simulated liver was 60 HU and we added numerous 5-to 10-mm structures with 60{+-}10 HU/mm. To mimic liver tumors we added nodules measuring 8, 10, and 12 mm in diameter with CT numbers of 60{+-}10, 60{+-}15, and 60{+-}20 HU. Five radiologists visually evaluated similarity of the texture of the computer-simulated liver phantom and a real human liver to confirm the appropriateness of the virtual liver images using a five-point scale. The total score was 44 in two radiologists, and 42, 41, and 39 in one radiologist each. They evaluated that the textures of virtual liver were comparable to those of human liver. Our computer-simulated liver phantom is a promising tool for the evaluation of the image quality and diagnostic performance of hepatic CT imaging. (orig.)

  17. Thoracic aortic aneurysm in a child due to cystic medial necrosis

    International Nuclear Information System (INIS)

    Kuribayashi, Sachio; Watabe, Tsuneya; Ohtaki, Makoto; Matsuyama, Shoya; Ogawa, Junichi

    1983-01-01

    The valuable role of computed tomography (CT) was stressed in the diagnosis of thoracic aortic aneurysm in an asymptomatic 12-year-old child. She initially presented mediastinal mass on plain chest film. A saccular thoracic aortic aneurysm was highly suspected from the CT findings, and it was confirmed on angiography. Pathological examination of the aneurysmal wall revealed cystic medial necrosis. (author)

  18. Computerized transverse tomography of vascular lesions of the brain. II. Aneurysms

    International Nuclear Information System (INIS)

    Pressman, B.D.; Gilbert, G.E.; Davis, D.O.

    1975-01-01

    Computerized transverse tomography (CTT) is an excellent screening examination for intracerebral disease. Unfortunately, the detection rate of small aneurysms by this procedure is not high. Nevertheless, CTT may be useful in aneurysm cases since it may indicate the need for further evaluation in patients with associated hematomas, encephalomalacia, or ventricular dilatation, even if the aneurysm itself is not delineated. (U.S.)

  19. The predictive role of health-promoting behaviours and perceived stress in aneurysmal rupture.

    Science.gov (United States)

    Lee, Mi-Sun; Park, Chang G; Hughes, Tonda L; Jun, Sang-Eun; Whang, Kum; Kim, Nahyun

    2018-03-01

    To examine the roles of two modifiable factors-health-promoting behaviours and perceived stress-in predicting aneurysmal rupture. Unruptured intracranial aneurysm detection produces significant stress and anxiety in patients because of the risk of rupture. Compared to nonmodifiable risk factors for rupture such as age, gender and aneurysm size/location, less attention has been given to modifiable risk factors. Two modifiable factors, health-promoting behaviours and perceived stress, have hardly been examined as potential predictors of rupture. This study used a cross-sectional design. We assessed 155 patients with intracranial aneurysms-that is, subarachnoid haemorrhage (n = 77) or unruptured intracranial aneurysm (n = 78)-to examine (i) baseline characteristics (patient and aneurysmal factors), (ii) health-related factors (lifestyle habits and health-promoting behaviour) and (iii) perceived stress levels (psychological stress and physical stress). Patient records provided medical histories and aneurysmal factors; other data were collected using a structured questionnaire addressing lifestyle habits, the Health-Promoting Lifestyle Profile-II to measure health-promoting behaviour and the Perceived Stress Questionnaire to measure perceived-psychological stress and perceived-physical stress levels. Bivariate analysis indicated that aneurysm rupture risk was associated with female gender, aneurysm size/location, defecation frequency, hyperlipidaemia, sedentary time, low Health-Promoting Lifestyle Profile-II mean scores and high perceived-psychological stress scores. After adjusting for known risk factors, the mean Health-Promoting Lifestyle Profile-II and perceived-psychological stress scores remained robust predictors of rupture. Furthermore, known risk factors combined with these scores had greater predictive power than known risk factors alone. Health-promoting behaviour and psychological stress are promising modifiable factors for reducing risk of aneurysmal

  20. Volume changes of extremely large and giant intracranial aneurysms after treatment with flow diverter stents

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Angelo; Byrne, James V. [ohn Radcliffe Hospital, Oxford Neurovascular and Neuroradiology Research Unit, Nuffield Department of Surgical Sciences, Oxford (United Kingdom); Rane, Neil; Kueker, Wilhelm; Cellerini, Martino; Corkill, Rufus [John Radcliffe Hospital, Department of Neuroradiology, Oxford (United Kingdom)

    2014-01-15

    This study assessed volume changes of unruptured large and giant aneurysms (greatest diameter >20 mm) after treatment with flow diverter (FD) stents. Clinical audit of the cases treated in a single institution, over a 5-year period. Demographic and clinical data were retrospectively collected from the hospital records. Aneurysm volumes were measured by manual outlining at sequential slices using computerised tomography (CT) or magnetic resonance (MR) angiography data. The audit included eight patients (seven females) with eight aneurysms. Four aneurysms involved the cavernous segment of the internal carotid artery (ICA), three the supraclinoid ICA and one the basilar artery. Seven patients presented with signs and symptoms of mass effect and one with seizures. All but one aneurysm was treated with a single FD stent; six aneurysms were also coiled (either before or simultaneously with FD placement). Minimum follow-up time was 6 months (mean 20 months). At follow-up, three aneurysms decreased in size, three were unchanged and two increased. Both aneurysms that increased in size showed persistent endosaccular flow at follow-up MR; in one case, failure was attributed to suboptimal position of the stent; in the other case, it was attributed to persistence of a side branch originating from the aneurysm (similar to the endoleak phenomenon of aortic aneurysms). At follow-up, five aneurysms were completely occluded; none of these increased in volume. Complete occlusion of the aneurysms leads, in most cases, to its shrinkage. In cases of late aneurysm growth or regrowth, consideration should be given to possible endoleak as the cause. (orig.)

  1. Diagnosis of mycotic abdominal aortic aneurysm using 67-gallium citrate

    International Nuclear Information System (INIS)

    Blumoff, R.L.; McCartney, W.; Jaques, P.; Johnson, G. Jr.

    1982-01-01

    Mycotic aneurysms of the abdominal aorta are uncommon, but potentially lethal problems. Clinical subtleties may suggest their presence, but in the past, definitive diagnosis has been dependent on surgical exploration or autopsy findings. A case is presented in which 67-gallium citrate abdominal scanning localized the site of sepsis in an abdominal aortic aneurysm and allowed for prompt and successful surgical therapy. This noninvasive technique is recommended as a adjunct in the diagnosis of mycotic abdominal aortic aneurysms

  2. Diagnosing thoracic venous aneurysm: A contemporary imaging perspective

    Directory of Open Access Journals (Sweden)

    Rohit Aggarwal

    2017-01-01

    Full Text Available Thoracic venous aneurysms are a rare clinical entity and contrast-enhanced computed tomography has been the cornerstone of their diagnosis. We are reporting a rare case of isolated left brachiocephalic vein aneurysm, which was surgically managed, highlighting the role of dynamic contrast-enhanced magnetic resonance imaging as a definitive diagnostic modality in this patient.

  3. Glue embolization of the giant aneurysm by reducing thrombosis-induced volume expansion effect

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Yoo Kyung; Suh, Dae Chul [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2015-04-15

    A giant aneurysm due to a large intra-aneurysmal volume can be complicated by a delayed massive volume expansion caused by thrombus formation. To prevent such a severe mass effect, we obliterated the aneurysmal lumen by gluing and prevented further development of thrombosis. A 52-year-old female with a giant aneurysm at the cavernous segment of the internal carotid artery presented with tinnitus and intermittent diplopia. After confirming with a negative occlusion test, the right internal carotid artery was trapped by coiling and with further obliteration of the aneurysmal lumen by gluing. She developed a mild diplopia after the procedure and recovered without any deficit. The magnetic resonance angiography showed a stable occlusion of the aneurysm and good collateral filling of the cerebral vessel 15 months later.

  4. Glue embolization of the giant aneurysm by reducing thrombosis-induced volume expansion effect

    International Nuclear Information System (INIS)

    Yeom, Yoo Kyung; Suh, Dae Chul

    2015-01-01

    A giant aneurysm due to a large intra-aneurysmal volume can be complicated by a delayed massive volume expansion caused by thrombus formation. To prevent such a severe mass effect, we obliterated the aneurysmal lumen by gluing and prevented further development of thrombosis. A 52-year-old female with a giant aneurysm at the cavernous segment of the internal carotid artery presented with tinnitus and intermittent diplopia. After confirming with a negative occlusion test, the right internal carotid artery was trapped by coiling and with further obliteration of the aneurysmal lumen by gluing. She developed a mild diplopia after the procedure and recovered without any deficit. The magnetic resonance angiography showed a stable occlusion of the aneurysm and good collateral filling of the cerebral vessel 15 months later.

  5. Idiopathic multiple aneurysm of external carotid artery

    Directory of Open Access Journals (Sweden)

    Saravanan Balachandran

    2014-01-01

    Full Text Available Aneurysms of external carotid artery are rare. Treatments for these are undertaken for the prevention of complications like hemorrhage or rupture, and embolism. We present a 71-year-old male with idiopathic multiple aneurysm for the past 34 years on conservative management and regular follow up for the past 4 years. This case was discussed for the rarity of idiopathic multiple aneurysm of the external carotid artery and the need for individualized treatment protocol to be followed as in this case, only watchful observation considering the age and patient compliance. In this world of evolving surgical techniques and newer treatment modalities, conservative treatment still has a role to play. Primary care physicians at the community level have a major role in following these patients and referring them as and when the need arises.

  6. Isolated aneurysms of the iliac arteries

    International Nuclear Information System (INIS)

    Eckmann, A.; Schild, H.; Schmiedt, W.; Groenninger, J.

    1988-01-01

    Isolated aneurysms of the iliac arteries are rare. They must be considered as a disease pattern of their own as against aneurysms of the abdominal aorta because of the specific anatomical conditions in the pelvis. The clinical symptomatology is determinated by their localisation and topographical relationships within teh pelvis; this can give rise to problems in differential diagnosis primary urological, neurological or gastrointestinal diseases. The prognosis is decisively determined early and correct diagnosis because of the danger of rupture. Sonography, computed tomography and angiography are indispensable aids in preoperative planning. (orig.) [de

  7. Nursing experience in clinical endovascular treatment for renal artery aneurysms

    International Nuclear Information System (INIS)

    Dong Yanfen; Pan Xiaoxia; Luan Shaoliang; Wei Ren

    2012-01-01

    Objective: To discuss the standardized clinical nursing measures for patients receiving endovascular treatment of renal artery aneurysms. Methods: The clinical data of 9 patients with renal artery aneurysm, who were admitted to authors' hospital during the period from Jan. 2010 to Aug. 2011 and received endovascular treatment, were retrospectively analyzed. The related nursing points as well as the received endovascular. Results: A total of 9 cases with renal artery aneurysm were treated nursing measures were summarized. Results: A total of 9 cases with renal artery aneurysm were with interventional management, including embolization (n = 6), stent implantation (n = 2) and stent implantation together with coil embolization (n = 1). The mean hospitalization time was (10±2) days. Postoperative retention of urine was observed in one patient and postoperative retroperitoneal hemorrhage occurred in another patient. Neither nursing-related nor operation-related complications occurred. Conclusion: Standardized perioperative nursing care for patients with renal artery aneurysm can surely help enhance the patient's tolerance to the surgery, and effectively prevent the complications. (authors)

  8. Natural history and surgical results in patients with unruptured intracranial aneurysms

    International Nuclear Information System (INIS)

    Okiyama, Koichi; Nagano, Osamu; Machida, Toshio; Serizawa, Toru; Ono, Junichi; Higuchi, Yoshinori

    2008-01-01

    The management of patients with unruptured intracranial aneurysms (UIAs) is controversial. We aimed to assess the natural history of UIAs and evaluate the surgical results. We analyzed 154 patients (181 saccular UIAs) with no history of subarachnoid hemorrhage (SAH) from a different aneurysm. Aneurysms were detected by magnetic resonance angiography (MRA) or by 3-dimensional CT angiography. Although the most frequent reason for the diagnosis was routine brain examinations of healthy patients or a vague symptom such as headache or dizziness, 15 patients were symptomatic. The natural history in patients who did not have surgery (follow-up group: 76 cases, 95 aneurysms) was assessed, and the surgical outcome of UIAs (surgical group: 78 cases, 86 aneurysms) was evaluated. Among 76 patients in the follow-up group, 7 had SAH. The mean latency period to aneurysm rupture was 3.2 months. The aneurysms with subsequent bleeding ranged from 5 to 25 mm (19.3 mm on average), whereas those without ranged from 1 to 28 mm (4.5 mm on average). The rupture rates of UIAs in anterior and posterior circulation were 6.2% and 14.3%, respectively. All ruptured cases were females. Mortality and morbidity associated with UIAs in the follow-up group were 3.9% and 3.9%, respectively. In the surgical group, no mortality was noted. Permanent morbidity associated with prospective repair of UIAs was 5.1%, although the morbidity of the patients with preoperative Rankin scores of 0 or 1 was 1.3%. Transient morbidity was observed in 6 patients (7.7%) with the size of the aneurysm 19.8 mm on average. The natural history and surgical results in patients with UIAs are modified by several factors including aneurysm size and location, the patient's age and gender, the medical status and the patient's preoperative Rankin score. The present results indicated that these factors should be considered in deciding whether to treat UIAs, and that careful assessment of the surgical benefits might be essential

  9. Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study.

    Science.gov (United States)

    Ionita, Ciprian N; Dohatcu, Andreea; Sinelnikov, Andrey; Sherman, Jason; Keleshis, Christos; Paciorek, Ann M; Hoffmann, K R; Bednarek, D R; Rudin, S

    2009-01-01

    Image-guided endovascular intervention (EIGI), using new flow modifying endovascular devices for intracranial aneurysm treatment is an active area of stroke research. The new polyurethane-asymmetric vascular stent (P-AVS), a vascular stent partially covered with a polyurethane-based patch, is used to cover the aneurysm neck, thus occluding flow into the aneurysm. This study involves angiographic imaging of partially covered aneurysm orifices. This particular situation could occur when the vascular geometry does not allow full aneurysm coverage. Four standard in-vivo rabbit-model aneurysms were investigated; two had stent patches placed over the distal region of the aneurysm orifice while the other two had stent patches placed over the proximal region of the aneurysm orifice. Angiographic analysis was used to evaluate aneurysm blood flow before and immediately after stenting and at four-week follow-up. The treatment results were also evaluated using histology on the aneurysm dome and electron microscopy on the aneurysm neck. Post-stenting angiographic flow analysis revealed aneurysmal flow reduction in all cases with faster flow in the distally-covered case and very slow flow and prolonged pooling for proximal-coverage. At follow-up, proximally-covered aneurysms showed full dome occlusion. The electron microscopy showed a remnant neck in both distally-placed stent cases but complete coverage in the proximally-placed stent cases. Thus, direct flow (impingement jet) removal from the aneurysm dome, as indicated by angiograms in the proximally-covered case, was sufficient to cause full aneurysm healing in four weeks; however, aneurysm healing was not complete for the distally-covered case. These results support further investigations into the treatment of aneurysms by flow-modification using partial aneurysm-orifice coverage.

  10. An extracardiac unruptured right sinus of valsalva aneurysm complicated with atherothrombosis

    Directory of Open Access Journals (Sweden)

    Jun Zhang

    2016-04-01

    Full Text Available We present quite a rare case of extracardiac unruptured right sinus of valsalva aneurysm (SVA complicated with atherothrombosis in a young adult man. A 35-year-old male with a giant unruptured SVA arising from the right coronary sinus (RCS with extracardiac protrusion was diagnosed by echocardiography. Contrast-enhanced computed tomography (CT revealed a huge calcified aneurysm with mural thrombi originating from the aortic root, and about 80% stenosis at the initial segment of the right coronary artery (RCA. Intraoperative exploration demonstrated a giant unruptured aneurysm arising from the RCS. Different from other SVAs reported before, this aneurismal wall appeared thick and atheromatous-like. In this aneurysm, there was a small localized intima tearing and mural thrombosis, and the orifice of the RCA was almost blocked. This patient underwent surgical patch repair to prevent aneurysm rupture and coronary artery bypass grafting for RCA revascularization. In conclusion, the pathological examination demonstrated marked foam cells, inflammatory cells, and thrombosis in the aneurismal wall. Learning points: • Echocardiographic characteristics of sinus of valsalva aneurysm (SVA. • Diagnostic evaluation of extracardiac unruptured SVA. • Pathology of rare SVA.

  11. THE ACOUSTIC DETECTION OF INTRACRANIAL ANEURYSMS - A CLINICAL-STUDY

    NARCIS (Netherlands)

    VANBRUGGEN, AC; MOOIJ, JJA; JOURNEE, HL

    1991-01-01

    A new recording method for the acoustical detection of intracranial aneurysms is presented. A study examining the capability of the method to discriminate between patients with an aneurysm and control patients by a simple, objective parameter is reported. Sound signals were recorded over the eyes,

  12. Brain aneurysm patients seen in Harare, Zimbabwe: cases review ...

    African Journals Online (AJOL)

    Setting: Parirenyatwa Group of Hospitals and Avenues Clinic, Harare, Zimbabwe. Subjects: Adult intracranial aneurysm patients. Interventions: Craniotomy and aneurysm clipping. Results: Seventeen patients were seen during the period of study. Twelve were female patients while five were male with a male to female ratio ...

  13. Safety and Efficacy of Aneurysm Treatment with the WEB

    DEFF Research Database (Denmark)

    Pierot, L; Gubucz, I; Buhk, J H

    2017-01-01

    BACKGROUND AND PURPOSE: Flow disruption with the Woven EndoBridge (WEB) device is an innovative technique for the endovascular treatment of wide-neck bifurcation aneurysms. The initial version of the device (WEB Double-Layer) was evaluated in the WEB Clinical Assessment of IntraSaccular Aneurysm ...

  14. The New Low-Profile WEB 17 System for Treatment of Intracranial Aneurysms: First Clinical Experiences.

    Science.gov (United States)

    van Rooij, S B T; Peluso, J P; Sluzewski, M; Kortman, H G; van Rooij, W J

    2018-05-01

    The Woven EndoBridge (WEB) is an intrasaccular flow diverter intended to treat wide-neck aneurysms. The latest generation WEBs needed a 0.021-inch microcatheter in the small sizes. Recently, a lower profile range of WEBs compliant with a 0.017-inch microcatheter (WEB 17) has been introduced. We present the first clinical results of treatment of both ruptured and unruptured aneurysms with the WEB 17. Between December 2016 and September 2017, forty-six aneurysms in 40 patients were treated with the WEB 17. No supporting stents or balloons were used. Twenty-five aneurysms were ruptured (54%). There were 6 men and 34 women (mean age, 62 years; median, 63 years; range, 46-87 years). The mean aneurysm size was 4.9 mm (median, 5 mm; range, 2-7 mm). There were 2 thromboembolic procedural complications without clinical sequelae and no ruptures. The overall permanent procedural complication rate was 0% (0 of 40; 97.5% CI, 0%-10.4%). Imaging follow-up at 3 months was available in 33 patients with 39 aneurysms (97.5% of 40 eligible aneurysms). In 1 aneurysm, the detached WEB was undersized and the remnant was additionally treated with coils after 1 week. This same aneurysm reopened at 3 months and was again treated with a second WEB. One other aneurysm showed persistent WEB filling at 3 months. Complete occlusion was achieved in 28 of 39 aneurysms (72%), and 9 aneurysms (23%) showed a neck remnant. The WEB 17 is safe and effective for both ruptured and unruptured aneurysms. The WEB 17 is a valuable addition to the existing WEB size range, especially for very small aneurysms. © 2018 by American Journal of Neuroradiology.

  15. Microneurosurgical Management of Posterior Communicating Artery Aneurysm: A Contemporary Series from Helsinki.

    Science.gov (United States)

    Thiarawat, Peeraphong; Jahromi, Behnam Rezai; Kozyrev, Danil A; Intarakhao, Patcharin; Teo, Mario K; Choque-Velasquez, Joham; Hernesniemi, Juha

    2017-05-01

    The objectives of this study were to analyze microsurgical techniques and to determine correlations between microsurgical techniques and the radiographic findings in the microneurosurgical treatment of posterior communicating artery aneurysms (PCoAAs). We retrospectively analyzed radiographic findings and videos of surgeries in 64 patients with PCoAAs who underwent microsurgical clipping by the senior author from August 2010 to 2014. From 64 aneurysms, 30 (47%) had acute subarachnoid hemorrhage (SAH) that necessitated lamina terminalis fenestration (odds ratio [OR], 67.67; P < 0.001) and Liliequist membrane fenestration (OR, 19.62; P < 0.001). The low-lying aneurysms significantly necessitated the coagulation of the dura covering the anterior clinoid process (ACP) (OR, 7.43; P = 0.003) or anterior clinoidectomy (OR, 91.0; P < 0.001). We preferred straight clips in 45 (83%) of 54 posterolateral projecting aneurysms (OR, 45.0; P < 0.001), but preferred curved clips for posteromedial projecting aneurysms (OR, 6.39; P = 0.008). The mean operative time from the brain retraction to the final clipping was 17 minutes and 43 seconds. Postoperative computed tomography angiography revealed complete occlusion of 60 (94%) aneurysms. Three (4.6%) patients with acute SAH suffered postoperative lacunar infarction. For ruptured aneurysms, lamina terminalis and Liliequist membrane fenestration are useful for additional cerebrospinal fluid drainage. For low-lying aneurysms, coagulation of the dura covering the ACP or tailored anterior clinoidectomy might be necessary for exposing the proximal aneurysm neck. Type of clips depends on the direction of projection. The microsurgical clipping of the PCoAAs can achieve good immediate complete occlusion rate with low postoperative stroke rate. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Relationship between Angiographic Results and Morphology in Sidewall Intracranial Aneurysms after Stent-Assisted Coil Embolization.

    Science.gov (United States)

    Nii, Kouhei; Aikawa, Hiroshi; Tsutsumi, Masanori; Eto, Ayumu; Iko, Minoru; Sakamoto, Kimiya; Inoue, Ritsuro; Mitsutake, Takafumi; Hanada, Hayatsura; Kazekawa, Kiyoshi

    2016-03-01

    Stent-assisted coil embolization (SACE) is used to address wide-necked or complex aneurysms. However, as they may recanalize after SACE, predictors of recanalization are needed. We investigated the relationship between follow-up angiographic results and the morphology of sidewall (SW) aneurysms in patients treated by SACE. Between September 2010 and September 2014, we performed 80 SACE procedures for SW intracranial aneurysms. Angiographic findings, obtained immediately after the procedure, 3-6 months thereafter, and when aneurysmal recanalization was suspected on MR angiogram scan, were recorded. Morphologically, the SW aneurysms were classified as "outside" (OS) and "partially inside" (PI) based on the curve of the axes of the proximal or distal parent artery with respect to the aneurysmal neck. Follow-up angiographic studies on OS- and PI SW aneurysms were compared. On the initial angiograms, we classified 42 aneurysms as OS and 38 as PI. Immediately after SACE, there was no significant difference in the angiographic findings on OS and PI aneurysms. However, on follow-up angiograms, there was a significant difference in the rate of spontaneous improvement (4 of 42 [OS] versus 21 of 38 [PI], P = .001). We performed additional coil embolization to treat 3 recanalized OS aneurysms. SW aneurysms classified morphologically as PI tended to occlude progressively even after incomplete occlusion by SACE. In contrast, aneurysms classified as OS must be observed carefully after SACE. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  17. Diagnostic pitfalls associated with a large true posterior communicating artery aneurysm: a case report.

    Science.gov (United States)

    Nagatani, Kimihiro; Otani, Naoki; Seno, Soichiro; Takeuchi, Satoru; Wada, Kojiro; Mori, Kentaro

    2013-10-01

    True posterior communicating artery (PCoA) aneurysm is an aneurysm that originates from the PCoA, and large or giant true PCoA aneurysms are rare. We report a case of a large true PCoA aneurysm successfully clipped after anterior clinoidectomy and discuss the diagnostic pitfalls associated with this rare clinical entity.

  18. Prevalence of Unruptured Intracranial Aneurysm on MR Angiography

    International Nuclear Information System (INIS)

    Jeon, Tae Yeon; Jeon, Pyoung; Kim, Keon Ha

    2011-01-01

    To evaluate the prevalence of incidentally found unruptured intracranial aneurysms (UIAs) on the brain MR angiography (MRA) from a community-based general hospital. This was a prospectively collected retrospective study, carried out from January 2004 to December 2004. The subjects included 3049 persons from a community-based hospital in whom MRA was performed according to a standardized protocol in an outpatient setting. Age- and sex-specific prevalence of UIAs was calculated. The results by MRA were compared with intra-arterial digital subtraction angiography (DSA) findings. Unruptured intracranial aneurysms were found in 137 (5%) of the 3049 patients (M:F 43:94; mean age, 60.2 years). The prevalence of UIAs was 5% (n = 94) in women and 4% (n = 43) in men, respectively (p = 0.2046) and showed no age-related increase. The most common site of aneurysm was at the distal internal carotid artery (n = 64, 39%), followed by the middle cerebral artery (n = 40, 24%). In total, 99% of aneurysms measured less than 12 mm, and 93% of aneurysms measured less than 7 mm. Direct comparisons between MRA and DSA were available in 70 patients with 83 UIAs; the results revealed two false positive and two false negative results. This community-hospital based study suggested a higher prevalence of UIAs observed by MRA than previously reported. These findings should be anticipated in the design and use of neuroimaging in clinical practice.

  19. Evaluation of paraclinoid aneurysm by using contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Tsuboi, Toshiyuki; Takahashi, Kazuya; Date, Isao; Mandai, Shinya; Kinugasa, Kazushi; Nishimoto, Akira

    2004-01-01

    Juxta-dural ring aneurysms of the internal carotid artery have different clinical courses and risks of subarachnoid hemorrhage (SAH) depending upon their positions in the intradural or extradural spaces. The goal of this study was to localize such aneurysms using contrast enhanced-MR Angiography (CE-MRA). CE-MRA studies were performed in 18 patients with juxta-dural ring aneurysms using three-dimensional time-of-flight spoiled gradient-recalled acquisition in the steady state (3D-TOF-SPGR) sequence. Imaging parameters were as follows: 33/3.4/1 (repetition time/echo time/number of excitation (TR/TE/NEX)), flip angle 25 deg, 256 x 192 matrix, 0.8-mm slice thickness, 60 sections in total (one slab), 180-mm field of view, with no magnetization transfer contrast (MTC), superior saturation (S sat) pulse, total imaging time 6 minutes 53 seconds. We evaluated both the source images of CE-MRA and multiplanar reconstruction (MPR) images. When the hyperintensity of the aneurysm was located within the hyperintensity of the contrast-enhanced cavernous sinus, we diagnosed the lesion as an intracavernous, ''extradural'' aneurysm. In addition, we compared CE-MRA with operative findings. Seven patients out of 18 were treated surgically. In all, MRI findings corresponded well with the operative findings. We believe CE-MRA and its MPR images using 3D-TOF-SPGR sequence is a useful technique to evaluate juxta-dural ring aneurysms. (author)

  20. Endovascular aneurysm exclusion along a femorodistal venous bypass in active Behçet's disease.

    Science.gov (United States)

    Gretener, Silvia B; Do, Dai-Do; Baumgartner, Iris; Dinkel, Hans-Peter; Schmidli, Jürg; Birrer, Manuela

    2002-10-01

    To report the endovascular repair of dual aneurysms along a femorodistal venous bypass graft in a patient with Behçet's disease. A 55-year-old man of middle European ancestry with Behçet's disease had dual aneurysms evolve along the proximal segment of a femorodistal venous bypass that had been implanted 2.5 years earlier for recurrent false aneurysm formation. Owing to the lack of suitable venous conduits and the active nature of the disease, the aneurysms were successfully excluded with overlapping Hemobahn and Jostent endografts; the immunosuppressive therapy was intensified. Rupture of the aneurysms was successfully prevented, but the stent-grafts thrombosed 6 weeks later owing to exacerbation of the underlying disease. Endovascular exclusion of aneurysm in venous bypass grafts in Behçet's disease is feasible. Although the stent-grafts thrombosed, they did prevent rupture of the aneurysms.

  1. Intracranial aneurysm and arachnoid cyst: just a coincidence? A case report.

    Science.gov (United States)

    Aguiar, Guilherme Brasileiro de; Santos, Rafael Gomes Dos; Paiva, Aline Lariessy Campos; Silva, João Miguel de Almeida; Silva, Rafael Carlos da; Veiga, José Carlos Esteves

    2017-12-18

    Presence of an arachnoid cyst and a non-ruptured intracystic brain aneurysm is extremely rare. The aim of this paper was to describe a case of a patient with an arachnoid cyst and a non-ruptured aneurysm inside it. Clinical, surgical and radiological data were analyzed and the literature was reviewed. A patient complained of chronic headache. She was diagnosed as having a temporal arachnoid cyst and a non-ruptured middle cerebral artery aneurysm inside it. Surgery was performed to clip the aneurysm and fenestrate the cyst. This report raises awareness about the importance of intracranial vascular investigation in patients with arachnoid cysts and brain hemorrhage.

  2. Endovascular Tubular Stent-Graft Placement for Isolated Iliac Artery Aneurysms

    International Nuclear Information System (INIS)

    Okada, Takuya; Yamaguchi, Masato; Kitagawa, Atsushi; Kawasaki, Ryota; Nomura, Yoshikatsu; Okita, Yutaka; Sugimura, Kazuro; Sugimoto, Koji

    2012-01-01

    Purpose: To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Materials and Methods: Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non–contrast-enhanced CT was performed in seven patients with chronic kidney disease. Results: All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47–2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p < 0.05) decreased from 42.0 (9.3) to 36.9 (13.6) mm and from 40.1 (13.0) to 33.6 (15.8) mm, respectively; the mean (SD) shrinkage rates were 15.1% (20.2%) and 18.9% (22.4%), respectively. The primary patency rate was 100%, and no secondary interventions were required. Four patients (21%) developed transient buttock claudication, and one patient (5%) developed colorectal ischaemia, which was treated conservatively. Conclusion: Endovascular tubular stent-graft placement for the repair of isolated IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.

  3. Surgical management of an ACM aneurysm eight years after coiling.

    Science.gov (United States)

    Pogády, P; Fellner, F; Trenkler, J; Wurm, G

    2007-04-01

    The authors present a case report on rebleeding of a medial cerebral aneurysm (MCA) eight years after complete endovascular coiling. The primarily successfully coiled MCA aneurysm showed a local regrowth which, however, was not the source of the rebleeding. The angiogram demonstrated no evidence of contrast filling of the coiled segment, but according to intraoperative findings (haematoma location, displacement of coils, evident place of rupture) there is no doubt that the coiled segment of the aneurysm was responsible for the haemorrhage.

  4. The use of novel flow diverting device Tubridge for the treatment of intracranial aneurysms: initial experience

    International Nuclear Information System (INIS)

    Yang Pengfei; Liu Jianmin; Huang Qinghai; Xu Yi; Hong Bo; Zhao Wenyuan; Li Qiang; Fang Yibin; Zhang Yuhui

    2011-01-01

    Objective: To preliminarily evaluate the feasibility, efficacy and safety of the novel flow diverting device, Tubridge, in treating intracranial aneurysms. Methods: The novel flow diverting device, Tubridge, was employed to treat intracranial aneurysms in 14 patients with a mean age of (52.4±10.2) years. A total of 14 intracranial aneurysms were detected in 14 patients, including 13 un-ruptured aneurysms and one ruptured aneurysms. The technical results and clinical data were analyzed. Results: A total of 18 flow diverters were implanted. The flow diverter was successfully conveyed and delivered in all patients, with a technical success rate of 100%. Six aneurysms were treated with the flow diverter together with the coils. Of the six aneurysms, complete obliteration of the aneurysm was obtained in 2 (Raymond grade Ⅰ), remnant of neck was seen in 1 (Raymond grade Ⅱ) and residual aneurysm sac was found in 3 (Raymond grade Ⅲ) cases. Eight aneurysms were treated with flow diverter implantation alone. After the procedure, marked decrease in contrast filling of the aneurysm sac was seen in 3 aneurysms, while the change in contrast filling pattern of the aneurysm sac as well as the obvious retention of contrast in the aneurysm sac could be detected in all cases. No procedure-related hemorrhagic or ischemic complications occurred. The mRS score at the time of discharge was 0 (n=13) or 1 (n=1). Conclusion: For the treatment of some special type intracranial aneurysms, the use of Tubridge flow diverter is clinically feasible, its effect is immediate and satisfactory with higher safety in short term. However, its long-term efficacy and safety need to be further evaluated. (authors)

  5. Closed-cell stent for coil embolization of intracranial aneurysms: clinical and angiographic results.

    Science.gov (United States)

    Wakhloo, A K; Linfante, I; Silva, C F; Samaniego, E A; Dabus, G; Etezadi, V; Spilberg, G; Gounis, M J

    2012-10-01

    Recanalization is observed in 20-40% of endovascularly treated intracranial aneurysms. To further reduce the recanalization and expand endovascular treatment, we evaluated the safety and efficacy of closed-cell SACE. Between 2007 and 2010, 147 consecutive patients (110 women; mean age, 54 years) presenting at 2 centers with 161 wide-neck ruptured and unruptured aneurysms were treated by using SACE. Inclusion criteria were wide-neck aneurysms (>4 mm or a dome/neck ratio ≤ 2). Clinical outcomes were assessed by the mRS score at baseline, discharge, and follow-up. Aneurysm occlusion was assessed on angiograms by using the RS immediately after SACE and at follow-up. Eighteen aneurysms (11%) were treated following rupture. Procedure-related mortality and permanent neurologic deficits occurred in 2 (1.4%) and 5 patients (3.4%), respectively. In total, 7 patients (4.8%) died, including 2 with reruptures. Of the 140 surviving patients, 113 (80.7%) patients with 120 aneurysms were available for follow-up neurologic examination at a mean of 11.8 months. An increase in mRS score from admission to follow-up by 1, 2, or 3 points was seen in 7 (6.9%), 1 (1%), and 2 (2%) patients, respectively. Follow-up angiography was performed in 120 aneurysms at a mean of 11.9 months. Recanalization occurred in 12 aneurysms (10%), requiring retreatment in 7 (5.8%). Moderate in-stent stenosis was seen in 1 (0.8%), which remained asymptomatic. This series adds to the evidence demonstrating the safety and effectiveness of SACE in the treatment of intracranial aneurysms. However, SACE of ruptured aneurysms and premature termination of antiplatelet treatment are associated with increased morbidity and mortality.

  6. Endovascular repair as a sole treatment in multiple aneurysms in patient with SLE

    International Nuclear Information System (INIS)

    Dineva, S.; Al-Amin, M.; Demetriou, S.; Tsetis, D.

    2013-01-01

    Full text: Introduction: Most aneurysms are local manifestations of systemic disease. For patients over 65 years the incidence of aneurysm of the abdominal aorta (AAA) is approximately 5-6% in men and 1-2 % for women. The presence of both the AAA and aneurysms in other location is even rarer, and this percentage is likely increase further in patients with systemic lupus erythematosus (SLE). What you will learn: We present a rare clinical case of endovascular treatment of multifocal aneurysm including post catheterization pseudoaneurysm. The patient is a 73 years old woman with a history of SLE and age-related comorbidity. Originally an endovascular treatment of aneurysms of the abdominal aorta and right common iliac artery was used. Two years later a successfully endovascular treatment of aneurysm of the right renal artery was conducted, which however is complicated by the formation of a pseudoaneurysm in access through the left femoral artery. The late one is again treated endovascular by placement of a covered stent after failure of percutaneous injection of 1000 UI thrombin. Discussion: Adult patients with a long history of SLE are unsuitable candidates for surgical treatment of aneurysmal disease, especially in its multifocal form. In our case we have taken multistep successful endovascular procedures, including technically hard placing of the stent at the site of the right renal aneurysms, and post catheterization pseudoaneurysm. Conclusion: Multifocal aneurysmal vascular changes due to macroangiopathia in SLE can be treated alone by endovascular means in multi-stages procedures

  7. Endovascular treatment of intracranial aneurysms with bioactive Cerecyte coils: effects on treatment stability

    International Nuclear Information System (INIS)

    Geyik, Serdar; Yavuz, Kivilcim; Ergun, Onur; Koc, Osman; Cekirge, Saruhan; Saatci, Isil

    2008-01-01

    The Cerecyte coils were developed to improve long-term stability of embolized cerebral aneurysms by producing an increased fibrous reaction over the neck of the aneurysms. We report our preliminary clinical experience with mid-term follow-up. Seventy-eight consecutive patients with 84 intracranial aneurysms treated exclusively with Cerecyte coils were included in this study. Forty-eight aneurysms were ruptured and 36 were incidental. Twenty-two aneurysms were small with ( 25 mm). The embolization technique was the same with that in standard bare coiling. Immediate post-procedure angiography demonstrated complete aneurysm occlusion in 69%, neck remnant in 29.8% and incomplete occlusion in 1.2%. Follow-up angiography was obtained in 80 aneurysms in a period of time ranging from 6 months to 2 years. The overall recanalization rate was 11.3%, and the re-treatment rate was 6.3%; in the subgroup analysis, recanalization rates were 4.5% in S/S; 9.8% in S/W; and 33.3% in large aneurysms. The only giant aneurysm also showed recanalization. Procedure-related morbidity and mortality rates were 2.6% and 1.3%, respectively. Our midterm results showed a relatively low rate of recurrence compared to those reported for platinum coils with morbidity and mortality rates comparable to those with standard bare platinum coils. The efficacy of Cerecyte coils in the long term will be specifically addressed by the ongoing randomized Cerecyte coil trial. (orig.)

  8. Endovascular treatment of experimentally induced aneurysms in rabbits using stents: a feasibility study

    International Nuclear Information System (INIS)

    Hans, F.J.; Thiex, R.; Gilsbach, J.M.; Krings, T.; Moeller-Hartmann, W.; Dreeskamp, H.; Stein, K.P.; Meetz, A.; Thron, A.; Pfeffer, J.; Scherer, K.; Brunn, A.

    2003-01-01

    Although Guglielmi detachable coil (GDC) systems have been generally accepted for treatment of intracranial aneurysms, primary stenting of aneurysms using porous stents or implantation of coils after stent placement remains experimental. Testing of these new methods requires an animal model which imitates human aneurysms in size, configuration and neck morphology. We assessed in detail the technical requirements of and steps for transfemoral stent treatment of experimentally induced aneurysms at the top of the brachiocephalic trunk in rabbits. We created aneurysms in ten rabbits by distal ligation and intraluminal digestion of the right common carotid artery with elastase. We treated five animals with porous stents alone, and five with stents plus coiling via the meshes of the stent, which permitted dense packing of coils. No complications related to the procedures occurred. In all animals, even in those treated solely with porous stents, total occlusion of the aneurysm was achieved. Our animal model can be suitable for testing the biocompatibility and occlusion rate of new methods and devices for the treatment of experimental aneurysms. (orig.)

  9. Maffucci's syndrome associated with chondrosarcoma and aneurysm: case report

    International Nuclear Information System (INIS)

    Lim, Hyoung Gun; Yoo, Won Jong; Lim, Yeon Soo; Sung, Mi Sook; Chung, Myung Hee; Lee, Hae Giu; Jung, So Lyung; Kim, Jae Na

    2002-01-01

    Maffucci syndrome is rare congenital non-inherited condition characterized by multiple enchondromas and cutaneous hemangiomas. It is associated with increased risk of malignancy, including chondrosarcomas, and because of generalized mesodermal dysplasia, aneurysms can develop. We present a case of maffucci syndrome associated with intracranial chondrosarcoma and aneurysm

  10. Trans-aortic repair of a sinus of valsalva aneurysm.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; Ieromonachos, Constantinos; Stavridis, George; Antoniou, Theofani A; Athanassopoulos, George; Cokkinos, Dennis V; Alivizatos, Peter A

    2007-01-01

    Sinus of Valsalva aneurysms are rare and vary in their presentation and approach of surgical repair. We report on a case of isolated right sinus of Valsalva aneurysm that underwent successful excision and patch repair with individual sutures placed through the annulus of the aortic valve.

  11. The safety of vasopressor-induced hypertension in subarachnoid hemorrhage patients with coexisting unruptured, unprotected intracranial aneurysms.

    Science.gov (United States)

    Reynolds, Matthew R; Buckley, Robert T; Indrakanti, Santoshi S; Turkmani, Ali H; Oh, Gerald; Crobeddu, Emanuela; Fargen, Kyle M; El Ahmadieh, Tarek Y; Naidech, Andrew M; Amin-Hanjani, Sepideh; Lanzino, Giuseppe; Hoh, Brian L; Bendok, Bernard R; Zipfel, Gregory J

    2015-10-01

    Vasopressor-induced hypertension (VIH) is an established treatment for patients with aneurysmal subarachnoid hemorrhage (SAH) who develop vasospasm and delayed cerebral ischemia (DCI). However, the safety of VIH in patients with coincident, unruptured, unprotected intracranial aneurysms is uncertain. This retrospective multiinstitutional study identified 1) patients with aneurysmal SAH and 1 or more unruptured, unprotected aneurysms who required VIH therapy (VIH group), and 2) patients with aneurysmal SAH and 1 or more unruptured, unprotected aneurysms who did not require VIH therapy (non-VIH group). All patients had previously undergone surgical or endovascular treatment for the presumed ruptured aneurysm. Comparisons between the VIH and non-VIH patients were made in terms of the patient characteristics, clinical and radiographic severity of SAH, total number of aneurysms, number of ruptured/unruptured aneurysms, aneurysm location/size, number of unruptured and unprotected aneurysms during VIH, severity of vasospasm, degree of hypervolemia, and degree and duration of VIH therapy. For the VIH group (n = 176), 484 aneurysms were diagnosed, 231 aneurysms were treated, and 253 unruptured aneurysms were left unprotected during 1293 total days of VIH therapy (5.12 total years of VIH therapy for unruptured, unprotected aneurysms). For the non-VIH group (n = 73), 207 aneurysms were diagnosed, 93 aneurysms were treated, and 114 unruptured aneurysms were left unprotected. For the VIH and non-VIH groups, the mean sizes of the ruptured (7.2 ± 0.3 vs 7.8 ± 0.6 mm, respectively; p = 0.27) and unruptured (3.4 ± 0.2 vs 3.2 ± 0.2 mm, respectively; p = 0.40) aneurysms did not differ. The authors observed 1 new SAH from a previously unruptured, unprotected aneurysm in each group (1 of 176 vs 1 of 73 patients; p = 0.50). Baseline patient characteristics and comorbidities were similar between groups. While the degree of hypervolemia was similar between the VIH and non-VIH patients

  12. Mycotic Aneurysm of the Celiac Trunk: From Early CT Sign to Rupture

    International Nuclear Information System (INIS)

    Serafino, Gianpiero; Vroegindeweij, Dammis; Boks, Simone; Harst, Erwin van der

    2005-01-01

    We present a case of the rapid development and rupture of a mycotic celiac trunk aneurysm. Initiallyon multislice computed tomography (ms-CT) there was a normal celiac trunk with minimal haziness of the surrounding fat. Only 2 weeks later the patient went into hypovolemic shock due to a ruptured celiac aneurysm. Although aneurysms of the visceral arteries are rare, they are of major clinical importance as they carry a life-threatening risk of rupture. This case illustrates the use of ms-CT in detecting and evaluating visceral aneurysms, in order to prevent emergency operation

  13. Two cases of false aneurysm rupture induced by nonvascular tumor

    International Nuclear Information System (INIS)

    Nakamura, Hiromasa; Komiya, Tatsuhiko; Tamura, Nobushige; Sakaguchi, Genichi; Kobayashi, Taira; Furukawa, Tomokuni; Matsushita, Akihito; Sunagawa, Gengo; Murashita, Takashi

    2008-01-01

    We presented here 2 cases of rare nonvascular tumor involving the aorta. A 69-year-old woman. She presented leg edema and dyspnea on admission. Computed tomography revealed abdominal aortic aneurysm perforating left common iliac vein. Abdominal aortic aneurysm replacement and fistula closure were done on an emergency basis. Immunohistologic examination revealed that malignant mesothelioma invaded the aortic wall. A 47-year-old woman presented with dyspnea. Enhanced computed tomography revealed rupture of the descending aortic aneurysm (saccular type). Aortic replacement was done on an emergency basis. One year after the operation, computed tomography revealed a giant mass (160 x 70 mm) surrounding the descending thoracic aorta. On biopsy, malignant schwannoma was found to invade the descending aorta. Sometimes nonvascular tumors form aneurysms. So we should be careful in diagnosis before operation. (author)

  14. Effect of phantom voxelization in CT simulations

    International Nuclear Information System (INIS)

    Goertzen, Andrew L.; Beekman, Freek J.; Cherry, Simon R.

    2002-01-01

    In computer simulations of x-ray CT systems one can either use continuous geometrical descriptions for phantoms or a voxelized representation. The voxelized approach allows arbitrary phantoms to be defined without being confined to geometrical shapes. The disadvantage of the voxelized approach is that inherent errors are introduced due to the phantom voxelization. To study effects of phantom discretization, analytical CT simulations were run for a fan-beam geometry with phantom voxel sizes ranging from 0.0625 to 2 times the reconstructed pixel size and noise levels corresponding to 10 3 -10 7 photons per detector pixel prior to attenuation. The number of rays traced per detector element was varied from 1 to 16. Differences in the filtered backprojection images caused by changing the phantom matrix sizes and number of rays traced were assessed by calculating the difference between reconstructions based on the finest matrix and coarser matrix simulations. In noise free simulations, all phantom matrix sizes produced a measurable difference in comparison with the finest phantom matrix used. When even a small amount of noise was added to the projection data, the differences due to the phantom discretization were masked by the noise, and in all cases there was almost no improvement by using a phantom matrix that was more than twice as fine as the reconstruction matrix. No substantial improvement was achieved by tracing more than 4 rays per detector pixel

  15. Management of ruptured anterior communicating artery aneurysms presenting with sudden paraplegia

    Directory of Open Access Journals (Sweden)

    Jiu-hong MA

    2016-10-01

    Full Text Available Objective  To explore the causes of ruptured anterior communicating artery aneurysms presenting with paraplegia, and summarize the key points of diagnosis and treatment methods. Methods  A total of 260 patients with ruptured anterior communicating artery aneurysms were received medical treatment in the Department of Neurosurgery, Shanxi Provincial People's Hospital from Jan. 2012 to Mar. 2015. Of which 6 patients were clinically presented with paraplegia, their clinical data including CT/MR/DSA were retrospectively analyzed, and based on the analysis, aneurysm embolization and anti-vasospasm treatment were performed. Results  Besides headache and discomfort in the neck, 5 of the 6 patients were with double lower limbs paraplegia, and the another one presented quadriplegia. By symptomatic treatment of aneurysm embolization and anti vasospasm, the myodynamia of the paraplegic limbs recovered from 0-Ⅰto Ⅳ-Ⅴgrade, and 2 of the 6 patients spent a shorter recovery time (about 2 weeks, the other 4 recovered in 3 months. The limbs myodynamia of the 6 patients recovered completely in half-and one year follow up. Conclusions  The mechanism of ruptured anterior communicating artery aneurysms presenting with paraplegia may be the insufficient blood supply to the primary motor area and supplementary motor area (SMA of brain cortex caused by aneurysms rupture. Aneurysm embolization should be performed in clinical treatment, supplemented with anti vasospasm and symptomatic treatment of improving neurological function. DOI: 10.11855/j.issn.0577-7402.2016.09.14

  16. Vertebral artery dissecting aneurysms: report of 3 cases and review of the literature

    International Nuclear Information System (INIS)

    Li Zequn; Zhong Ming; Tan Xianxi; Zhen Weiming; Lu Xianghe; Lin Chen

    2005-01-01

    Objective: To investigate the features, diagnosis and the ideal therapy of vertebral dissecting aneurysms. Methods: Three vertebral dissecting aneurysms were performed endovascular treatment, 2 with stents implantation and embolization, one parental artery and aneurysm occlusion. The course of the diagnosis and treatment were analyzed correlating with the literature. Results: One male, two female, 56-66 years old. 2 presented SAH, one complained of vertigo. The features on DSA: 2 showed pearl and string sign, that was, aneurismal dilation accompanied by proximal and/or distal narrowing; one demonstrated fusiform aneurysm. Two cases recovered well, one died after procedure. Conclusions: Endovascular treatment is the ideal choice to treat the vertebral dissecting aneurysms. (authors)

  17. Velocity profile and wall shear stress of saccular aneurysms at the anterior communicating artery.

    Science.gov (United States)

    Yamaguchi, Ryuhei; Ujiie, Hiroshi; Haida, Sayaka; Nakazawa, Nobuhiko; Hori, Tomokatsu

    2008-01-01

    It has recently been shown that the aspect ratio (dome/neck) of an aneurysm correlates well with intraaneurysmal blood flow. Aneurysms with an aspect ratio larger than 1.6 carry a higher risk of rupture. We examined the effect of aspect ratio (AR) on intra-aneurysmal flow using experimental models. Flow visualization with particle imaging velocimetry and measurement of wall shear stress using laser Doppler anemometry were performed on three different aneurysm models: AR 0.5, 1.0, and 2.0. Intraaneurysmal flow consists of inflow, circulation, and outflow. Rapid inflow impinged on the distal neck creating a stagnant point. Rapid flow and maximum wall shear stress were observed in the vicinity of the stagnant point. By changing the Reynold's number, the stagnant point moved. By increasing the AR of the aneurysm, vortices inside the aneurysm sac closed and very slow flow was observed, resulting in very low shear stress markedly at a Reynold's number of 250, compatible with the diastolic phase. In the aneurysm model AR 2.0, both rapid flow at the neck and vortices inside the aneurysm are sufficient to activate platelets, making a thrombus that may anchor on the dome where very slow flow takes place. Hemodynamics in aneurysms larger than AR 2.0 definitely contribute to thrombus formation.

  18. 2D MR angiography of the aortic aneurysm

    International Nuclear Information System (INIS)

    Amanuma, Makoto; Hasegawa, Makoto; Watabe, Tsuneya; Heshiki, Atsuko

    1992-01-01

    2D time-of-flight MR angiography was performed in 6 cases of thoracic aortic aneurysm. Oblique saturation pulses were used to suppress the signals of the pulmonary artery and SVC, providing excellent selective MR aortograms. Three dimensional extension of the aneurysm and its relation with cervical branches were easily assessed. It could be possible to replace invasive aortography by this technique. (author)

  19. Soft tissue aneurysmal bone cyst

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X.L.; Gielen, J.L.; Delrue, F.; De Schepper, A.M.A. [Department of Radiology, Universitair Ziekenhuis Antwerpen (University of Antwerp), Wilrijkstraat 10, 2650, Edegem (Belgium); Salgado, R. [Department of Pathology, Universitair Ziekenhuis Antwerpen (University of Antwerp), Wilrijkstraat 10, 2650, Edegem (Belgium)

    2004-08-01

    A soft tissue aneurysmal bone cyst located in the right gluteus medius of a 21-year-old man is reported. On conventional radiography, the lesion demonstrated a spherically trabeculated mass with a calcific rim. On CT scan, it showed a well-organized peripheral calcification resembling a myositis ossificans. On MRI, it presented as a multilocular, cystic lesion with fluid-fluid levels. The lesion had no solid components except for intralesional septa. Although findings on imaging and histology were identical to those described in classical aneurysmal bone cyst, diagnosis was delayed because of lack of knowledge of this entity and its resemblance to the more familiar post-traumatic heterotopic ossification (myositis ossificans). (orig.)

  20. Soft tissue aneurysmal bone cyst

    International Nuclear Information System (INIS)

    Wang, X.L.; Gielen, J.L.; Delrue, F.; De Schepper, A.M.A.; Salgado, R.

    2004-01-01

    A soft tissue aneurysmal bone cyst located in the right gluteus medius of a 21-year-old man is reported. On conventional radiography, the lesion demonstrated a spherically trabeculated mass with a calcific rim. On CT scan, it showed a well-organized peripheral calcification resembling a myositis ossificans. On MRI, it presented as a multilocular, cystic lesion with fluid-fluid levels. The lesion had no solid components except for intralesional septa. Although findings on imaging and histology were identical to those described in classical aneurysmal bone cyst, diagnosis was delayed because of lack of knowledge of this entity and its resemblance to the more familiar post-traumatic heterotopic ossification (myositis ossificans). (orig.)

  1. Endovascular strategy for unruptured cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Mangiafico, S., E-mail: mangiax@libero.it [Interventional Neuroradiology Unit, Careggi University Hospital, Florence (Italy); Guarnieri, G., E-mail: gianluigiguarnieri@hotmail.it [Neuroradiology Service, Cardarelli Hospital, Naples (Italy); Consoli, A., E-mail: onemed21@gmail.com [Interventional Neuroradiology Unit, Careggi University Hospital, Florence (Italy); Ambrosanio, G., E-mail: gambros@libero.it [Neuroradiology Service, Cardarelli Hospital, Naples (Italy); Muto, M., E-mail: mutomar@tiscali.it [Neuroradiology Service, Cardarelli Hospital, Naples (Italy)

    2013-10-01

    The treatment of unruptured intracranial aneurysms (UIAs) remains complex and not clearly defined. While for ruptured intracranial aneurysms the management and the treatment option (surgery or endovascular treatment) are well defined by several trials, for asymptomatic UIAs the best management is still currently uncertain. The rationale to treat an UIA is to prevent the rupture and its consequent SAH and all complications derived from hemorrhage or reduce/eliminate neurological palsy. Although this statement is correct, the indication to treat an UIA should be based on a correct balance between the natural history of UIA and treatment risk. Patient's clinical history, aneurysm characteristics, and strategy management influence the natural history of UIAs and treatment outcomes. In the last 10 years and more, two important large multicenter studies were performed in order to analysis of all these factors and to evaluate the best treatment option for UIAs. The aim of this paper is to try to synthesize the possible indications to the endovascular treatment (EVT), when and how to treat an UIA.

  2. Ten-Year Follow-Up of Endovascular Aneurysm Treatment with Talent Stent-Grafts

    International Nuclear Information System (INIS)

    Pitton, Michael B.; Scheschkowski, Tobias; Ring, Markus; Herber, Sascha; Oberholzer, Katja; Leicher-Dueber, Annegret; Neufang, Achim; Schmiedt, Walther; Dueber, Christoph

    2009-01-01

    The purpose of this study was to evaluate the clinical results, complications, and secondary interventions during long-term follow-up after endovascular aneurysm repair (EVAR) and to investigate the impact of endoleak sizes on aneurysm shrinkage. From 1997 to March 2007, 127 patients (12 female, 115 male; age, 73.0 ± 7.2 years) with abdominal aortic aneurysms were treated with Talent stent-grafts. Follow-up included clinical visits, contrast-enhanced MDCT, and radiographs at 3, 6, and 12 months and then annually. Results were analyzed with respect to clinical outcome, secondary interventions, endoleak rate and management, and change in aneurysm size. There was no need for primary conversion surgery. Thirty-day mortality was 1.6% (two myocardial infarctions). Procedure-related morbidity was 2.4% (paraplegia, partial infarction of one kidney, and inguinal bleeding requiring surgery). Mean follow-up was 47.7 ± 34.2 months (range, 0-123 months). Thirty-nine patients died during follow-up; three of the deaths were related to aneurysm (aneurysm rupture due to endoleak, n = 1; secondary surgical reintervention n = 2). During follow-up, a total of 29 secondary procedures were performed in 19 patients, including 14 percutaneous procedures (10 patients) and 15 surgical procedures (12 patients), including 4 cases with late conversion to open aortic repair (stent-graft infection, n = 1; migration, endoleak, or endotension, n = 3). Overall mean survival was 84.5 ± 4.7 months. Mean survival and freedom from any event was 66.7 ± 4.5 months. MRI depicted significantly more endoleaks compared to MDCT (23.5% vs. 14.3%; P 10% of the aneurysm area were associated with reduced aneurysm shrinkage compared to no endoleaks or <10% endoleaks (Δ at 3 years, -1.8% vs. -12.0%; P < 0.05). In conclusion, endovascular aneurysm treatment with Talent stent-grafts demonstrated encouraging long-term results with moderate secondary intervention rates. Primary occlusion of all aortic side

  3. Galen's vein aneurysm as cause of heart failure

    International Nuclear Information System (INIS)

    Echeverria, Claudia; Cassalett, Gabriel; Franco, Jaime; Carrillo, Gustavo

    2005-01-01

    We present the case of a newborn admitted to the intensive care unit with a heart failure of difficult medical management. A large ductus arteriosus was found. It was surgically corrected, but the heart failure persisted and did not improve with medical treatment. Incidentally, a big Galen's vein aneurysm was found. Galen's vein aneurysm is a rare congenital pathology, originated by a fusion defect of the internal cerebral veins. Due to its low resistance, it produces a picture of high-output heart failure. Large defects may contain 50% to 60% of cardiac output. An aneurysm may be suspected in each newborn or infant with clinical picture of heart failure and right cardiac chamber dilation without any evidence of structural cardiac anomaly

  4. Extraosseous aneurysmal cyst in hand: a case report.

    Science.gov (United States)

    Sahu, Ajay; Gujral, Sarabjeet S; Gaur, Sanjeev

    2008-10-24

    The presence of primary aneurysmal cyst in soft tissues is a extremely rare and its presence in the soft tissues of hand has never been reported in literature before. We report the first ever case of extraosseous aneurysmal cyst in hand. A twelve years old girl presented with a swelling in the thenar region on palmer aspect of right hand growing slowly since three months. On X ray, CT scan and excision biopsy the lesion was found to be separate from bone and located in the soft tissue. Its diagnosis was confirmed on histopatholgical examination. Previously few authors have reported extraosseous aneurysmal cyst in the soft tissues of shoulder, hip and pelvic girdle but nobody has reported its presence in the soft tissues of hand.

  5. Surgical clipping as the preferred treatment for aneurysms of the middle cerebral artery

    NARCIS (Netherlands)

    van Dijk, J. Marc C.; Groen, Rob J. M.; Ter Laan, Mark; Jeltema, Johanna Rinck; Mooij, Jan Jacob A.; Metzemaekers, Jan D. M.

    2011-01-01

    In recent years the endovascular treatment of intracranial aneurysms (coiling) has progressively gained recognition, particularly after the publication of the International Subarachnoid Aneurysm Trial (ISAT) in 2002. Despite the fact that in ISAT middle cerebral artery (MCA) aneurysms were clearly

  6. Coil Embolization of Pancreaticoduodenal Artery Aneurysms Associated with Celiac Artery Stenosis: Report of Three Cases

    International Nuclear Information System (INIS)

    Ikeda, Osamu; Tamura, Yoshitaka; Nakasone, Yutaka; Kawanaka, Kohichi; Yamashita, Yasuyuki

    2007-01-01

    Aneurysms of the pancreaticoduodenal artery are rare. Degeneration of pancreaticoduodenal arcade vessels due to these aneurysms is associated with celiac artery stenosis or occlusion. Untreated lesions enlarge progressively and may rupture spontaneously. As the location of aneurysms of pancreaticoduodenal arcade vessels renders their surgical extirpation a challenge, we examined whether endovascular techniques offer a treatment alternative. We report on 3 patients with aneurysms of the pancreaticoduodenal arcade vessels and concomitant celiac artery stenosis/occlusion due to compression by the median arcuate ligament or chronic pancreatitis. All patients were treated by percutaneous coil embolization of the aneurysm. The aneurysmal sac was successfully excluded and the native circulation was preserved. Endovascular surgery can be used to treat these aneurysms safely and permits retention of the native circulation

  7. Immediate coma and poor outcome in subarachnoid haemorrhage are independently associated with an aneurysmal origin.

    Science.gov (United States)

    Tsermoulas, Georgios; Flett, Lisa; Gregson, Barbara; Mitchell, Patrick

    2013-08-01

    Subarachnoid haemorrhage (SAH) may present with coma and this is known to be associated with aneurysmal origin and blood load. Aneurysmal origin is associated with increased blood load and existing data do not allow us to determine if the association between coma and aneurysmal SAH is wholly due to blood load or if aneurysmal origin has an additional independent effect. The objective of our study is to find if an aneurysmal origin is a predictor of acute onset of coma independent of blood load. A series of consecutive patients with spontaneous SAH were divided into two groups: aneurysmal (aSAH) and non-aneurysmal--angiographically negative SAH (naSAH). Blood load was quantified so that the effect of aneurysmal origin could be resolved from the effect of the amount of blood spilled. Non-parametric regression was used to relate blood load to coma and poor outcome rates for aneurysmal bleeds. We analysed a total of 421 patients presenting during the period 2009-2011. Ninety aneurysmal cases presented with coma, seventy immediately in the early phase and seven shortly after rebleeding. None of the naSAH cases presented with immediate coma and 1 developed delayed coma. Delayed coma was associated with acute hydrocephalus in both groups. Aneurysmal origin was found to be an independent determinant of immediate coma (p=0.02) and poor outcome (pcoma and poor outcome in SAH are associated with an aneurysmal origin and do not characterize naSAH. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Risk factors for rebleeding of aneurysmal subarachnoid hemorrhage: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Chao Tang

    Full Text Available BACKGROUND: Rebleeding is a serious complication of aneurysmal subarachnoid hemorrhaging. To date, there are conflicting data regarding the factors contributing to rebleeding and their significance. METHODS: A systematic review of PubMed and Embase databases was conducted for studies pertaining to aneurysmal subarachnoid hemorrhage (aSAH and rebleeding in order to assess the associated risk factors. Odds ratios (ORs and corresponding 95% confidence intervals (CIs were estimated from fourteen studies comprised of a total of 5693 patients that met the inclusion criteria. RESULTS: Higher rebleeding rates were observed 10 mm in size (OR  = 1.70, 95% CI  = 1.35-2.14. CONCLUSIONS: Aneurysmal rebleeding occurs more frequently within the first 6 hours after the initial aSAH. Risk factors associated with rebleeding include high systolic pressure, the presence of an intracerebral or intraventricular hematoma, poor Hunt-Hess grade (III-IV, aneurysms in the posterior circulation, and an aneurysm >10 mm in size.

  9. Improved detection of anterior left ventricular aneurysm with multiharmonic fourier analysis

    International Nuclear Information System (INIS)

    Valette, H.B.; Bourguignon, M.H.; Merlet, P.; Gregoire, M.C.; Le Guludec, D.; Pascal, O.; Briandet, P.; Syrota, A.

    1990-01-01

    Single and multiharmonic Fourier analysis of LAO 30-45 degrees gated blood-pool studies were performed in a selected group of 30 patients with a left ventricular anterior aneurysm proven by contrast angiography. The sensitivity of the first harmonic phase image for the diagnosis of ventricular aneurysm was 80%. The clear phase shift (greater than 110 degrees) between the normal and the aneurysmal areas was missing in six patients. Peak acceleration images (negative maximum of the second derivative of the Fourier series) were calculated for each pixel with the analytical Fourier formula using two or three harmonics. A clear phase shift (greater than 126 degrees) than appeared in all the patients. This improvement was related to the increased weight of the second and third harmonics in the aneurysmal area when compared to control patients or to patients with dilative cardiomyopathy. Multiharmonic Fourier analysis clearly improved the sensitivity of the diagnosis of anterior left ventricular aneurysm on LAO 30 degrees-45 degrees gated blood-pool images

  10. Surgical ablation of ventricular tachycardia secondary to congenital ventricular septal aneurysm.

    Science.gov (United States)

    Graffigna, A; Minzioni, G; Ressia, L; Vigano, M

    1994-04-01

    Three patients underwent surgical ablation for ventricular tachycardia resulting from an aneurysm of the membranous portion of the ventricular septum. Two patients had a definite history of cardiac murmur during infancy, and one of them was found at the time of operation to have a left-to-right shunt through the apex of the aneurysm. The earliest ventricular activation sites were located around the neck of the aneurysm and were ablated in 1 patient by encircling the endocardial ventriculotomy and by cryoablation in the remaining 2. After focus resection had been completed, aneurysm resection and ventricular septal reconstruction were performed. All patients were alive and free of ventricular tachycardia and did not need medication as of 61, 66, and 88 months postoperatively. Spontaneous closure of a ventricular septal defect may lead to the formation of an aneurysm in the ventricular septum that may sustain ventricular tachycardias. Such arrhythmias can be effectively treated using electrically guided surgical techniques.

  11. Advanced technical skills are required for microsurgical clipping of posterior communicating artery aneurysms in the endovascular era.

    Science.gov (United States)

    Sanai, Nader; Caldwell, Nolan; Englot, Dario J; Lawton, Michael T

    2012-08-01

    Many neurosurgeons feel competent clipping posterior communicating artery (PCoA) aneurysms and include this lesion in their practice. However, endovascular therapy removes simple aneurysms that would have been easiest to clip with the best results. What remains are aneurysms with complex anatomy and technical challenges that are not well described. A contemporary surgical series with PCoA aneurysms is reviewed to define the patients, microsurgical techniques, and outcomes in current practice. A total of 218 patients had 218 PCoA aneurysms that were treated microsurgically during an 11-year period. Complexities influencing aneurysm management included (1) large/giant size; (2) fetal posterior cerebral artery; (3) previous coiling; (4) anterior clinoidectomy; (5) adherence of the anterior choroidal artery (AChA); (6) intraoperative aneurysm rupture; (7) complex clipping; and (8) atherosclerotic calcification. Simple PCoA aneurysms were encountered in 113 patients (51.8%) and complex aneurysms in 105 (48.2%). Adherent AChA (13.8%) and intraoperative rupture (11.5%) were the most common complexities. Simple aneurysms had favorable outcomes in 86.6% of patients, whereas aneurysms with 1 or multiple complexities had favorable outcomes in 78.2% and 75.0%, respectively. Intraoperative rupture (P PCoA aneurysms requires advanced techniques including clinoidectomy, AChA microdissection, complex clipping, and facility with intraoperative rupture. Microsurgery is recommended for recurrent aneurysms after coiling, complex branches, aneurysms causing oculomotor nerve palsy, multiple aneurysms, and patients with hematomas.

  12. Maffucci's syndrome associated with chondrosarcoma and aneurysm: case report

    International Nuclear Information System (INIS)

    Lim, Hyoung Gun; Yoo, Won Jong; Lim, Yeon Soo; Sung, Mi Sook; Chung Myung Hee; Lee, Hae Giu; Jung, So Lyung; Kim, Jea NA

    2002-01-01

    Maffucci syndrome is a rare congenital non-inherited condition characterized by multiple enchondromas and cutaneous hemangiomas. It is associated with increased risk of malignancy, including chondrosarcomas, and because of generalized mesodermal dysplasia, aneurysms can develop. We present a case of Maffucci syndrome associated with intracranial chondrosarcoma and aneurysm

  13. Radiation Exposure in Endovascular Infra-Renal Aortic Aneurysm Repair and Factors that Influence It

    Directory of Open Access Journals (Sweden)

    Rui Machado

    Full Text Available Abstract Objective: The endovascular repair of aortic abdominal aneurysms exposes the patients and surgical team to ionizing radiation with risk of direct tissue damage and induction of gene mutation. This study aims to describe our standard of radiation exposure in endovascular aortic aneurysm repair and the factors that influence it. Methods: Retrospective analysis of a prospective database of patients with abdominal infra-renal aortic aneurysms submitted to endovascular repair. This study evaluated the radiation doses (dose area product (DAP, fluoroscopy durations and their relationships to the patients, aneurysms, and stent-graft characteristics. Results: This study included 127 patients with a mean age of 73 years. The mean DAP was 4.8 mGy.m2, and the fluoroscopy time was 21.8 minutes. Aortic bilateral iliac aneurysms, higher body mass index, aneurysms with diameters larger than 60 mm, necks with diameters larger than 28 mm, common iliac arteries with diameters larger than 20 mm, and neck angulations superior to 50 degrees were associated with an increased radiation dose. The number of anatomic risk factors present was associated with increased radiation exposure and fluoroscopy time, regardless of the anatomical risk factors. Conclusion: The radiation exposure during endovascular aortic aneurysm repair is significant (mean DAP 4.8 mGy.m2 with potential hazards to the surgical team and the patients. The anatomical characteristics of the aneurysm, patient characteristics, and the procedure's technical difficulty were all related to increased radiation exposure during endovascular aortic aneurysm repair procedures. Approximately 40% of radiation exposure can be explained by body mass index, neck angulation, aneurysm diameter, neck diameter, and aneurysm type.

  14. Diagnosis of bronchial artery aneurysm by computed tomography: a case report

    Directory of Open Access Journals (Sweden)

    So Hyeon Bak, MD

    2017-09-01

    Full Text Available Bronchial artery aneurysm is a rare vascular abnormality, with an incidence of <1% based on diagnosis by selective bronchial angiography. It is manifested in various forms, ranging from an incidental finding on radiologic examination to life-threatening hemorrhage resulting from aneurysm rupture. We report a case of a 60-year-old man with a mediastinal bronchial artery aneurysm which was incidentally detected on chest computed tomography.

  15. Diagnosis of false proximal anastomosis aneurysms after aortofemoral reconstructive operations

    International Nuclear Information System (INIS)

    Pokrovskij, A.V.; Dan, V.N.; Karazeev, G.L.

    1993-01-01

    The paper deals with the diagnostic aspects of false aneurysms of proximal anastomosis of prostheses with the aorta on the basis of examination of 9 patients aged 3-65 years after aortofemoral reconstructive operations. The periods of the occurrence of false aneurysms were 2 weeks to 6 years. The causes of anastomosis aneurysms: infection, endartectomy fro the aorta at the site of applied anastomosis, progressive underlying disease. The authors provide strong evidence for a high informative value of various examinations, including ultrasound echoscanning, computer tomography, radioopaque aortography

  16. The multidetector computed tomography angiography (MDCTA) in the diagnosis of splenic artery aneurysm and pseudoaneurysm

    International Nuclear Information System (INIS)

    Saba, Luca; Mallarini, Giorgio; Anzidei, Michele; Lucatelli, Pierleone

    2011-01-01

    Splenic artery aneurysm is the most frequent visceral artery aneurysm and rupture of the aneurysm is associated with a high mortality rate. It is important to discriminate between a true aneurysm and a pseudoaneurysm that may be caused by pancreatitis, iatrogenic and postoperative causes, trauma and peptic ulcer disease. Multidetector-row CT angiography (MDCTA) allows detailed visualization of the vascular anatomy and may allow identification of aneurysms and pseudoaneurysms that affect the splenic artery. The objective of this article is to provide a review of the general characteristics of splenic artery aneurysms and pseudoaneurysms and to describe the findings of MDCTA

  17. The multidetector computed tomography angiography (MDCTA) in the diagnosis of splenic artery aneurysm and pseudoaneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Mallarini, Giorgio (Dept. of Radiology, Azienda Ospedaliero Universitaria (AOU), Cagliari (Italy)), email: lucasaba@tiscali.it; Anzidei, Michele; Lucatelli, Pierleone (Dept. of Radiological Sciences, Univ. of Rome La Sapienza, Rome (Italy))

    2011-06-15

    Splenic artery aneurysm is the most frequent visceral artery aneurysm and rupture of the aneurysm is associated with a high mortality rate. It is important to discriminate between a true aneurysm and a pseudoaneurysm that may be caused by pancreatitis, iatrogenic and postoperative causes, trauma and peptic ulcer disease. Multidetector-row CT angiography (MDCTA) allows detailed visualization of the vascular anatomy and may allow identification of aneurysms and pseudoaneurysms that affect the splenic artery. The objective of this article is to provide a review of the general characteristics of splenic artery aneurysms and pseudoaneurysms and to describe the findings of MDCTA

  18. Bleeding aneurysms of the celiac trunk

    International Nuclear Information System (INIS)

    Ziviello, M.; D'Isa, L.; Siani, A.; Maglione, F.; Cataldo, B.; Ziviello, R.; Capalbogiliberti, R.

    1988-01-01

    The authors report their experience in the study of bleeding aneurysms of the celiac arteries. Eleven patients were examined with US,CT, and angiography (8 hepatic artery aneurysms and 3 splenic artery aneurysms). Clinical findings included digestive bleeding, upper abdominal pain, palpable pulsating masses, and jaundice. Patient history included blunt abdominal trauma, penetrating trauma due to gunshot, acute pancreatitis, recent hepatic biospy. In all cases US showed an abdominal mass ranging in size from 2 to 10 cm. US findings included cyst-like lesions (8 cases), anobulated solid-like lesion, and complex lesion (2 cases). Continuity of the lesion with adjancent arterial vessels was noted in 5/11 cases, and pulsing activity in 3/11 cases. US patterns, although not specific, play an important role in the diagnosis when associated to other elements such as arterial continuity, mass pulsatility, patient history, and gastrointestinal bleeding. They suggest the need for more specific imaging exams, i.e. CT and angiography, and help avoid dangerous diagnostic biopsies. CT was performed to confirm US findings in 5 cases, and detected either hypodense cystic masses, or inhomogeneous masses with arterial enhancement after bolus injection of cm. CT was used to better demonstrate the lumen, patency of the vessel, the walls of the vessel, and the parietal thrombotic component. The typical arterial enhancement was the decisive finding for the diagnosis, even though a total continuity with arterial vessels was never observed. Angiography was the method of choice for the preoperative demonstration of hepatic artery aneurysms (10 cases) and for occlusive treatment with Gianturco coils (3 cases)

  19. The Japanese adult, child and infant phantoms

    International Nuclear Information System (INIS)

    Cristy, Mark; Egbert, Stephen D.

    1987-01-01

    The mathematical phantom for adult Japanese atomic-bomb survivors is a modification of the 57-kg ORNL (Oak Ridge National Laboratory) phantom for Western 15-year-old males and adult females. For younger Japanese survivors mathematical phantoms were similarly modified from the 18 and 9 kg ORNL phantoms for Western 5- and 1-year-olds, respectively. To make the phantom correspond more closely with dimensions and organ sizes recommended for Japanese adults by Maruyama and coworkers (cf E184), changes were made in the size of the lungs, the pancreas, the thyroid, and the testes and in the length of the legs. Also, the head-and-neck region was modified to improve the dose estimates for the thyroid from external radiation, after the ideas of Nagarajan et al. The arms were separated from the trunk to represent more accurately the shielding by the phantom in external exposures. Furthermore, provisions were made to provide a phantom in a kneeling posture. The elemental composition of the tissues was changed to that given by Kerr. The resulting phantom is slightly smaller in mass (55 kg). Details of these changes are given

  20. Fabrication of cerebral aneurysm simulator with a desktop 3D printer.

    Science.gov (United States)

    Liu, Yu; Gao, Qing; Du, Song; Chen, ZiChen; Fu, JianZhong; Chen, Bing; Liu, ZhenJie; He, Yong

    2017-05-17

    Now, more and more patients are suffering cerebral aneurysm. However, long training time limits the rapid growth of cerebrovascular neurosurgeons. Here we developed a novel cerebral aneurysm simulator which can be better represented the dynamic bulging process of cerebral aneurysm The proposed simulator features the integration of a hollow elastic vascular model, a skull model and a brain model, which can be affordably fabricated at the clinic (Fab@Clinic), under $25.00 each with the help of a low-cost desktop 3D printer. Moreover, the clinical blood flow and pulsation pressure similar to the human can be well simulated, which can be used to train the neurosurgical residents how to clip aneurysms more effectively.

  1. Neurofibromatosis 1 vasculopathy manifesting as a peripheral aneurysm in an adolescent

    Energy Technology Data Exchange (ETDEWEB)

    Farmakis, Shannon G.; Khanna, Geetika [Washington University School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Han, Min; White, Frances [Washington University School of Medicine, Department of Pathology and Immunology, St. Louis, MO (United States)

    2014-10-15

    Arterial vasculopathy is a well-recognized but uncommon manifestation of neurofibromatosis type 1 (NF-1). It can manifest as stenoses, aneurysms or arteriovenous malformations. NF-1 vasculopathy typically involves the aorta, visceral arteries or carotid-vertebral circulation. Aortic and visceral vasculopathy typically presents as stenotic lesions, while aneurysms have been reported primarily in the subclavian/vertebral arteries. Aneurysms of the peripheral/extremity arteries are an extremely rare complication of NF-1 that may present as a mass or spontaneous rupture. We present the case of a teenage boy with an arm mass secondary to an aneurysm. We hope this case will increase recognition of the variable clinical manifestations of NF-1 vasculopathy among radiologists. (orig.)

  2. Etiology and Treatment Modalities of Occipital Artery Aneurysms.

    Science.gov (United States)

    Chaudhry, Nauman S; Gaynor, Brandon G; Hussain, Shahrose; Dernbach, Paul D; Aziz-Sultan, Mohammad A

    2017-06-01

    Aneurysms of the external carotid artery represent approximately 2% of cervical carotid aneurysms, with the majority being traumatic pseudoaneurysms. Given the paucity of literature available for guidance, the diagnosis, treatment, and follow-up of such lesions are completely individualized. We report an 83-year-old woman with an 8-week history of headache in the occipital region, transient episode of gait disturbance, and pulsatile tinnitus on the right. She had no history of trauma, surgery, autoimmune disease, or infection. Physical examination revealed a pulsatile mass tender to palpation in the right occipital scalp. The mass was surgically excised, and histopathological diagnosis of a true aneurysm was made. Postoperatively, the patient's symptoms resolved; however, 1 month after the procedure, she developed occipital neuralgia, which was successfully treated with a percutaneous nerve block. To the best of our knowledge, this is the second reported case of a true aneurysm of the occipital artery in a patient with no history of trauma. The clinical examination, diagnosis, and treatment are discussed and the literature is reviewed for previously reported cases. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Predictors of In-Hospital Death After Aneurysmal Subarachnoid Hemorrhage: Analysis of a Nationwide Database (Swiss SOS [Swiss Study on Aneurysmal Subarachnoid Hemorrhage]).

    Science.gov (United States)

    Stienen, Martin Nikolaus; Germans, Menno; Burkhardt, Jan-Karl; Neidert, Marian C; Fung, Christian; Bervini, David; Zumofen, Daniel; Röthlisberger, Michel; Marbacher, Serge; Maduri, Rodolfo; Robert, Thomas; Seule, Martin A; Bijlenga, Philippe; Schaller, Karl; Fandino, Javier; Smoll, Nicolas R; Maldaner, Nicolai; Finkenstädt, Sina; Esposito, Giuseppe; Schatlo, Bawarjan; Keller, Emanuela; Bozinov, Oliver; Regli, Luca

    2018-02-01

    To identify predictors of in-hospital mortality in patients with aneurysmal subarachnoid hemorrhage and to estimate their impact. Retrospective analysis of prospective data from a nationwide multicenter registry on all aneurysmal subarachnoid hemorrhage cases admitted to a tertiary neurosurgical department in Switzerland (Swiss SOS [Swiss Study on Aneurysmal Subarachnoid Hemorrhage]; 2009-2015). Both clinical and radiological independent predictors of in-hospital mortality were identified, and their effect size was determined by calculating adjusted odds ratios (aORs) using multivariate logistic regression. Survival was displayed using Kaplan-Meier curves. Data of n=1866 aneurysmal subarachnoid hemorrhage patients in the Swiss SOS database were available. In-hospital mortality was 20% (n=373). In n=197 patients (10.6%), active treatment was discontinued after hospital admission (no aneurysm occlusion attempted), and this cohort was excluded from analysis of the main statistical model. In the remaining n=1669 patients, the rate of in-hospital mortality was 13.9% (n=232). Strong independent predictors of in-hospital mortality were rebleeding (aOR, 7.69; 95% confidence interval, 3.00-19.71; P <0.001), cerebral infarction attributable to delayed cerebral ischemia (aOR, 3.66; 95% confidence interval, 1.94-6.89; P <0.001), intraventricular hemorrhage (aOR, 2.65; 95% confidence interval, 1.38-5.09; P =0.003), and new infarction post-treatment (aOR, 2.57; 95% confidence interval, 1.43-4.62; P =0.002). Several-and among them modifiable-factors seem to be associated with in-hospital mortality after aneurysmal subarachnoid hemorrhage. Our data suggest that strategies aiming to reduce the risk of rebleeding are most promising in patients where active treatment is initially pursued. URL: http://www.clinicaltrials.gov. Unique identifier: NCT03245866. © 2018 American Heart Association, Inc.

  4. Preoperative Evaluation and Endovascular Procedure of Intraoperative Aneurysm Rupture During Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Zha, Bin-Shan, E-mail: binszha2013@163.com; Zhu, Hua-Gang, E-mail: huagzhu@yeah.net; Ye, Yu-Sheng, E-mail: yeyusheng@aliyun.com; Li, Yong-Sheng, E-mail: 872868848@qq.com; Zhang, Zhi-Gong, E-mail: zzgedward@sina.com; Xie, Wen-Tao, E-mail: 345344347@qq.com [The First Affiliated Hospital of Anhui Medical University, Department of Vascular Surgery (China)

    2017-03-15

    Thoracic aortic aneurysms are now routinely repaired with endovascular repair if anatomically feasible because of advantages in safety and recovery. However, intraoperative aneurysm rupture is a severe complication which may have an adverse effect on the outcome of treatment. Comprehensive preoperative assessment and considerate treatment are keys to success of endovascular aneurysm repair, especially during unexpected circumstances. Few cases have reported on intraoperative aortic rupture, which were successfully managed by endovascular treatment. Here, we present a rare case of an intraoperative aneurysm rupture during endovascular repair of thoracic aortic aneurysm with narrow neck and angulated aorta arch (coarctation-associated aneurysm), which was successfully treated using double access route approach and iliac limbs of infrarenal devices.Level of EvidenceLevel 5.

  5. Onyx combined with coiling embolization for endovascular treatment of complex intracranial ruptured aneurysms

    International Nuclear Information System (INIS)

    Wu Yongfa; Huang Qinghai; Yang Pengfei; Zhang Lei; Li Qiang; Liu Jianmin

    2011-01-01

    Objective: To study the therapeutic effect of Onyx combined with stent-assisted coiling in embolizing complex intracranial ruptured aneurysms. Methods: Onyx combined with stent-assisted coiling embolization was conducted in two patients with complex intracranial ruptured aneurysms. The clinical data were retrospectively analyzed. The related literature concerning intracranial complex aneurysm treated with Onyx was reviewed. Results: Two intracranial complex aneurysms were embolized with Onyx together with coils. The lesions were located at internal carotid arterial bifurcation (n=1) and at the anterior wall of internal carotid artery (n=1). Complete embolization of the aneurysms was achieved immediately after the procedure while the parent arteries remained patent. Conclusion: For the treatment of complex intracranial ruptured aneurysms Onyx combined with coiling embolization is safe, effective and feasible. This technique can improve the degree of embolization. To make the evaluation of the long-term efficacy further study is needed. (authors)

  6. Phantom cosmologies and fermions

    International Nuclear Information System (INIS)

    Chimento, Luis P; Forte, Monica; Devecchi, Fernando P; Kremer, Gilberto M

    2008-01-01

    Form invariance transformations can be used for constructing phantom cosmologies starting with conventional cosmological models. In this work we reconsider the scalar field case and extend the discussion to fermionic fields, where the 'phantomization' process exhibits a new class of possible accelerated regimes. As an application we analyze the cosmological constant group for a fermionic seed fluid

  7. Relationship between aneurysm occlusion and flow diverting device oversizing in a rabbit model.

    Science.gov (United States)

    Hodis, Simona; Ding, Yong-Hong; Dai, Daying; Lingineni, Ravi; Mut, Fernando; Cebral, Juan; Kallmes, David; Kadirvel, Ramanathan

    2016-01-01

    Implanted, actual flow diverter pore density is thought to be strongly influenced by proper matching between the device size and parent artery diameter. The objective of this study was to characterize the correlation between device sizing, metal coverage, and the resultant occlusion of aneurysms following flow diverter treatment in a rabbit model. Rabbit saccular aneurysms were treated with flow diverters (iso-sized to proximal parent artery, 0.5 mm oversized, or 1.0 mm oversized, respectively, n=6 for each group). Eight weeks after implantation, the angiographic degree of aneurysm occlusion was graded (complete, near-complete, or incomplete). The ostium of the explanted aneurysm covered with the flow diverter struts was photographed. Based on gross anatomic findings, the metal coverage and pore density at the ostium of the aneurysm were calculated and correlated with the degree of aneurysm occlusion. Angiographic results showed there were no statistically significant differences in aneurysm geometry and occlusion among groups. The mean parent artery diameter to flow diverter diameter ratio was higher in the 1.0 mm oversized group than in the other groups. Neither the percentage metal coverage nor the pore density showed statistically significant differences among groups. Aneurysm occlusion was inversely correlated with the ostium diameter, irrespective of the size of the device implanted. Device sizing alone does not predict resultant pore density or metal coverage following flow diverter implantation in the rabbit aneurysm model. Aneurysm occlusion was not impacted by either metal coverage or pore density, but was inversely correlated with the diameter of the ostium. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  8. Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft.

    LENUS (Irish Health Repository)

    Molony, David S

    2009-01-01

    BACKGROUND: Abdominal aortic aneurysms (AAA) are local dilatations of the infrarenal aorta. If left untreated they may rupture and lead to death. One form of treatment is the minimally invasive insertion of a stent-graft into the aneurysm. Despite this effective treatment aneurysms may occasionally continue to expand and this may eventually result in post-operative rupture of the aneurysm. Fluid-structure interaction (FSI) is a particularly useful tool for investigating aneurysm biomechanics as both the wall stresses and fluid forces can be examined. METHODS: Pre-op, Post-op and Follow-up models were reconstructed from CT scans of a single patient and FSI simulations were performed on each model. The FSI approach involved coupling Abaqus and Fluent via a third-party software - MpCCI. Aneurysm wall stress and compliance were investigated as well as the drag force acting on the stent-graft. RESULTS: Aneurysm wall stress was reduced from 0.38 MPa before surgery to a value of 0.03 MPa after insertion of the stent-graft. Higher stresses were seen in the aneurysm neck and iliac legs post-operatively. The compliance of the aneurysm was also reduced post-operatively. The peak Post-op axial drag force was found to be 4.85 N. This increased to 6.37 N in the Follow-up model. CONCLUSION: In a patient-specific case peak aneurysm wall stress was reduced by 92%. Such a reduction in aneurysm wall stress may lead to shrinkage of the aneurysm over time. Hence, post-operative stress patterns may help in determining the likelihood of aneurysm shrinkage post EVAR. Post-operative remodelling of the aneurysm may lead to increased drag forces.

  9. Identification of vortex structures in a cohort of 204 intracranial aneurysms.

    Science.gov (United States)

    Varble, Nicole; Trylesinski, Gabriel; Xiang, Jianping; Snyder, Kenneth; Meng, Hui

    2017-05-01

    An intracranial aneurysm (IA) is a cerebrovascular pathology that can lead to death or disability if ruptured. Abnormal wall shear stress (WSS) has been associated with IA growth and rupture, but little is known about the underlying flow physics related to rupture-prone IAs. Previous studies, based on analysis of a few aneurysms or partial views of three-dimensional vortex structures, suggest that rupture is associated with complex vortical flow inside IAs. To further elucidate the relevance of vortical flow in aneurysm pathophysiology, we studied 204 patient IAs (56 ruptured and 148 unruptured). Using objective quantities to identify three-dimensional vortex structures, we investigated the characteristics associated with aneurysm rupture and if these features correlate with previously proposed WSS and morphological characteristics indicative of IA rupture. Based on the Q -criterion definition of a vortex, we quantified the degree of the aneurysmal region occupied by vortex structures using the volume vortex fraction ( vVF ) and the surface vortex fraction ( sVF ). Computational fluid dynamics simulations showed that the sVF , but not the vVF , discriminated ruptured from unruptured aneurysms. Furthermore, we found that the near-wall vortex structures co-localized with regions of inflow jet breakdown, and significantly correlated to previously proposed haemodynamic and morphologic characteristics of ruptured IAs. © 2017 The Author(s).

  10. Post eclamptic aneurysmal rupture subarachnoid haemorrhage diagnosed in the puerperium

    International Nuclear Information System (INIS)

    Coolen, Teresa

    2006-01-01

    The incidence of subarachnoid and/or intracerebral haemorrhage in women during pregnancy is rare. The risk depends on the stage of pregnancy, but seems to be highest during the late third trimester, during delivery and in the puerperium. Headache can be a symptom of both preeclampsia, subarachnoid haemorrhage and other pathologies or conditions. It is essential for pregnant women with a suspected ruptured aneurysm to be investigated and treated without delay, irrespective of fear of harm to the foetus, to avoid complications from aneurysm rupture. This case study presents a 39-year-old woman who was 35 weeks and 3 days pregnant with known preeclampsia. She endured a headache for the three days leading up to the delivery with associated diplopia on the third day, but these symptoms were thought to be related to her preeclampsia. Over the three hours following childbirth, her headache became more severe and she suffered from vomiting, loss of vision, torticollis and seizures. Computed tomography (CT) of her head revealed a subarachnoid haemorrhage while CT angiography of the Circle of Willis failed to reveal an aneurysm and 4-vessel angiography only demonstrated an area slightly suspicious for the presence of an aneurysm. 3D rotational angiography clearly demonstrated a 1-2 mm aneurysm superior to the left terminal internal carotid artery. In this case, 3D rotational angiography proved to be a valuable additional technique. This patient underwent surgery for her ruptured aneurysm and has made an excellent recovery

  11. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy.

  12. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  13. Preoperative cerebral aneurysm assessment by three-dimensional CT angiography. Feasibility of surgery without cerebral angiography

    International Nuclear Information System (INIS)

    Kashiwagi, Shiro; Yamashita, Katsuhiro; Kato, Shoichi; Ito, Haruhide; Kurokawa, Kensuke; Watanabe, Yutaka

    1999-01-01

    The purpose of this study is to assess the capability of three-dimensional CT angiography (3D-CTA) to replace conventional catheter angiography as a preoperative examination for unruptured intracranial aneurysms. A prospective study was designed to evaluate 18 patients with 20 unruptured intracranial aneurysms (13 middle cerebral artery aneurysms, 6 anterior communicating artery aneurysms, and 1 internal carotid posterior communicating artery aneurysm) who underwent surgery. There were 12 women and 6 men with the average age of 63 years old. All patients were initially diagnosed as having intracranial aneurysms by MR angiography, followed by 3D-CTA and conventional catheter angiography for confirmation. Three experienced neurosurgeons were in charge of the operations. One of the neurosurgeons (surgeon 1) was provided with only 3D-CTA as the preoperative radiological evaluation, while the others (surgeon 2 and 3) were given through assessments with MRA, 3D-CTA, and conventional angiography. Surgeon 1 carried out the operations under careful observation by the surgeons 2 and 3. Problems encountered by the surgeon 1 during surgery were recorded. Neck clipping in 19 aneurysms and dome wrapping in 1 were successfully accomplished. All patients were discharged without complication. Surgeries went smoothly in 16 aneurysms with 3D-CTA alone. Discrepancies between the 3D-CTA findings and microsurgical anatomy were noted in 4 aneurysms: the size of the neck was overestimated in 3 aneurysms, the relationships to parent arteries were obscure in 2 aneurysms, and a perforating artery problematic to neck clipping was missed in 1 aneurysms by 3D-CTA. The results of this study support the notion that 3D-CTA can replace conventional catheter angiography as preoperative examination in the majority of regular-sized anterior circulation aneurysms. Nevertheless, surgeons should recognize and be prepared for the fact that 3D-CTA can give false impression about the aneurysm neck and

  14. Interesting images: Multiple coronary artery aneurysms.

    Science.gov (United States)

    Howard, Jonathon M; Viswanath, Omar; Armas, Alfredo; Santana, Orlando; Rosen, Gerald P

    2017-01-01

    We present the case of a 65-year-old male who presented with stable angina and dyspnea on exertion. His initial workup yielded a positive treadmill stress test for reversible apical ischemia, and transthoracic echocardiogram demonstrated impaired systolic function. Cardiac catheterization was then performed, revealing severe atherosclerotic disease including multiple coronary artery aneurysms. As a result, the patient was advised to and subsequently underwent a coronary artery bypass graft. This case highlights the presence of multiple coronary artery aneurysms and the ability to appreciate these pathologic findings on multiple imaging modalities, including coronary angiogram, transesophageal echocardiography, and direct visualization through the surgical field.

  15. Factors associated with outcomes in ruptured aneurysmal patients: Clinical Study of 80 Patients

    Directory of Open Access Journals (Sweden)

    Alfotih Gobran Taha Ahmed

    2015-03-01

    Full Text Available Background: Due to insufficient data in the literature, the optimal timing for surgical intervention for ruptured intracranial aneurysms is still controversial. Some practitioners advocate early surgery, but others not. It is important to identify other factors that can be used to predict poor prognosis in ruptured intracranial aneurysm patients. Objective: To determine the influence of timing of clipping surgery, and other factors on the outcomes of ruptured intracranial aneurysms in Hunt & Hess I~III grade patients. Method: We have performed a retrospective study involving 80 patients who were surgically treated for ruptured intracranial aneurysm between 2007 and 2012. The patient population consisted of 50(62.5% females and 30(37.5% males, with an age range of 12 to 75 years old, mean age 52.33 ± 10.63 years. We measured association between the Glasgow Outcome Scores and Sex, timing of clipping surgery, aneurysm location and pre-operative patient's neurological condition using famous Hunt and Hess grade system. Results: We did not find any correlation between the outcomes of ruptured intracranial aneurysm patients and timing (early, intermediate, late stage of clipping, sex, aneurysm location. Whereas there is a significant correlation between patients outcomes and pre-operative patient neurological condition (Hunt & Hess grade. Conclusion: Timing of Surgery (early, intermediate, late does not affect outcomes in low Hunt and Hess grade patients I~III. Whereas neurological condition (Hunt & Hess has strong impact on postoperative outcomes. Others factors like sex, Age, Aneurysm location have no effect on outcomes in ruptured intracranial aneurysms.

  16. Endovascular treatment of intracranial aneurysms with bioactive Cerecyte coils: effects on treatment stability

    Energy Technology Data Exchange (ETDEWEB)

    Geyik, Serdar; Yavuz, Kivilcim; Ergun, Onur; Koc, Osman; Cekirge, Saruhan [Hacettepe University Hospitals, Department of Radiology, Ankara (Turkey); Saatci, Isil [Hacettepe University Hospitals, Department of Radiology, Ankara (Turkey); Hacettepe University Hospital, Interventional Neuroradiology Unit, Department of Radiology, Ankara (Turkey)

    2008-09-15

    The Cerecyte coils were developed to improve long-term stability of embolized cerebral aneurysms by producing an increased fibrous reaction over the neck of the aneurysms. We report our preliminary clinical experience with mid-term follow-up. Seventy-eight consecutive patients with 84 intracranial aneurysms treated exclusively with Cerecyte coils were included in this study. Forty-eight aneurysms were ruptured and 36 were incidental. Twenty-two aneurysms were small with (<10 mm) small neck (<4 mm) (SASN); 55 were small with wide neck ({>=}4 mm) (SAWN); six were large (10-25 mm) (L); and one was giant (G) (>25 mm). The embolization technique was the same with that in standard bare coiling. Immediate post-procedure angiography demonstrated complete aneurysm occlusion in 69%, neck remnant in 29.8% and incomplete occlusion in 1.2%. Follow-up angiography was obtained in 80 aneurysms in a period of time ranging from 6 months to 2 years. The overall recanalization rate was 11.3%, and the re-treatment rate was 6.3%; in the subgroup analysis, recanalization rates were 4.5% in S/S; 9.8% in S/W; and 33.3% in large aneurysms. The only giant aneurysm also showed recanalization. Procedure-related morbidity and mortality rates were 2.6% and 1.3%, respectively. Our midterm results showed a relatively low rate of recurrence compared to those reported for platinum coils with morbidity and mortality rates comparable to those with standard bare platinum coils. The efficacy of Cerecyte coils in the long term will be specifically addressed by the ongoing randomized Cerecyte coil trial. (orig.)

  17. A statistically defined anthropomorphic software breast phantom

    International Nuclear Information System (INIS)

    Lau, Beverly A.; Reiser, Ingrid; Nishikawa, Robert M.; Bakic, Predrag R.

    2012-01-01

    Purpose: Digital anthropomorphic breast phantoms have emerged in the past decade because of recent advances in 3D breast x-ray imaging techniques. Computer phantoms in the literature have incorporated power-law noise to represent glandular tissue and branching structures to represent linear components such as ducts. When power-law noise is added to those phantoms in one piece, the simulated fibroglandular tissue is distributed randomly throughout the breast, resulting in dense tissue placement that may not be observed in a real breast. The authors describe a method for enhancing an existing digital anthropomorphic breast phantom by adding binarized power-law noise to a limited area of the breast. Methods: Phantoms with (0.5 mm) 3 voxel size were generated using software developed by Bakic et al. Between 0% and 40% of adipose compartments in each phantom were replaced with binarized power-law noise (β = 3.0) ranging from 0.1 to 0.6 volumetric glandular fraction. The phantoms were compressed to 7.5 cm thickness, then blurred using a 3 × 3 boxcar kernel and up-sampled to (0.1 mm) 3 voxel size using trilinear interpolation. Following interpolation, the phantoms were adjusted for volumetric glandular fraction using global thresholding. Monoenergetic phantom projections were created, including quantum noise and simulated detector blur. Texture was quantified in the simulated projections using power-spectrum analysis to estimate the power-law exponent β from 25.6 × 25.6 mm 2 regions of interest. Results: Phantoms were generated with total volumetric glandular fraction ranging from 3% to 24%. Values for β (averaged per projection view) were found to be between 2.67 and 3.73. Thus, the range of textures of the simulated breasts covers the textures observed in clinical images. Conclusions: Using these new techniques, digital anthropomorphic breast phantoms can be generated with a variety of glandular fractions and patterns. β values for this new phantom are comparable

  18. Endovascular treatment of cerebral aneurysms at Altai Regional Vascular Center

    Directory of Open Access Journals (Sweden)

    Д. А. Долженко

    2015-10-01

    Full Text Available A retrospective analysis of the results of endovascular treatment of patients with the brain aneurysms was carried out at the Neurosurgical Department of Regional Clinical Hospital in Barnaul over a period from 2009 to 2011. 52 patients with 57 cerebral aneurysms were included in the study and 55 endovascular interventions were performed. Total embolization (type A was used in 77% of patients, embolization type B was performed in 19% of cases, incomplete embolization (type C occurred in 4% of cases. 14 (26,9% patients were operated in the acute period of SAH. Conclusions are made relating to the effectiveness and relative safety of intravascular treatment of aneurysms, the need for differentiated approaches to the tactics of surgical treatment of patients in the acute period of hemorrhagic stroke due to the rupture of a cerebral aneurysm.

  19. F2-isoprostanes and F4-neuroprostanes as markers of intracranial aneurysm development.

    Science.gov (United States)

    Syta-Krzyżanowska, Anna; Jarocka-Karpowicz, Iwona; Kochanowicz, Jan; Turek, Grzegorz; Rutkowski, Robert; Gorbacz, Krzysztof; Mariak, Zenon; Skrzydlewska, Elżbieta

    2018-04-24

    Intracranial aneurysms are common, occurring in about 1-2% of the population. Saccular aneurysm is a pouch-like pathological dilatation of an intracranial artery that develops when the cerebral artery wall becomes too weak to resist hemodynamic pressure and distends. The aim of this study was to determine whether the development of intracranial aneurysms and subarachnoid hemorrhage (SAH) affects neuronal phospholipid metabolism, and what influence different invasive treatments have on brain free radical phospholipid metabolism. The level of polyunsaturated fatty acid (PUFA) cyclization products - F2-isoprostanes and F4-neuroprostanes - was examined using liquid chromatography - mass spectrometry (LC-MS) in the plasma of patients with brain aneurysm and resulting subarachnoid hemorrhage. It was revealed that an aneurysm leads to the enhancement of lipid peroxidation with a significant increase in plasma F2-isoprostanes and F4-neuroprostanes (more than 3-fold and 11-fold, respectively) in comparison to healthy subjects. The rupture of an aneurysm results in hemorrhage and an additional increase in examined prostaglandin derivatives. The embolization and clipping of aneurysms contribute to a gradual restoration of metabolic homeostasis in brain cells, which is visible in the decrease in PUFA cyclization products. The results indicate that aneurysm development is associated with enhanced inflammation and oxidative stress, factors which favor lipid peroxidation, particularly in neurons, whose membranes are rich in docosahexaenoic acid, a precursor of F4-neuroprostanes.

  20. Blood flow dynamic improvement with aneurysm repair detected by a patient-specific model of multiple aortic aneurysms.

    Science.gov (United States)

    Sughimoto, Koichi; Takahara, Yoshiharu; Mogi, Kenji; Yamazaki, Kenji; Tsubota, Ken'ichi; Liang, Fuyou; Liu, Hao

    2014-05-01

    Aortic aneurysms may cause the turbulence of blood flow and result in the energy loss of the blood flow, while grafting of the dilated aorta may ameliorate these hemodynamic disturbances, contributing to the alleviation of the energy efficiency of blood flow delivery. However, evaluating of the energy efficiency of blood flow in an aortic aneurysm has been technically difficult to estimate and not comprehensively understood yet. We devised a multiscale computational biomechanical model, introducing novel flow indices, to investigate a single male patient with multiple aortic aneurysms. Preoperative levels of wall shear stress and oscillatory shear index (OSI) were elevated but declined after staged grafting procedures: OSI decreased from 0.280 to 0.257 (first operation) and 0.221 (second operation). Graftings may strategically counter the loss of efficient blood delivery to improve hemodynamics of the aorta. The energy efficiency of blood flow also improved postoperatively. Novel indices of pulsatile pressure index (PPI) and pulsatile energy loss index (PELI) were evaluated to characterize and quantify energy loss of pulsatile blood flow. Mean PPI decreased from 0.445 to 0.423 (first operation) and 0.359 (second operation), respectively; while the preoperative PELI of 0.986 dropped to 0.820 and 0.831. Graftings contributed not only to ameliorate wall shear stress or oscillatory shear index but also to improve efficient blood flow. This patient-specific modeling will help in analyzing the mechanism of aortic aneurysm formation and may play an important role in quantifying the energy efficiency or loss in blood delivery.

  1. Male gender and smoking are related to single, but not to multiple, human aortic aneurysms.

    Science.gov (United States)

    Gutierrez, Paulo S; Leite, Thiago N P; Mangione, Fernanda M

    2015-01-01

    There is scanty information concerning multiple aortic aneurysms. Thus, we verified if clinical or pathological characteristics are different in patients with multiple (two or more) aortic aneurysms in comparison with those with only one. We selected at the necropsy files of the Heart Institute, São Paulo University School of Medicine, the last 100 cases with aortic aneurysms, comparing between the two groups: sex, age, presence of systemic arterial hypertension, diabetes, dyslipedemia, history of smoking habit, cause of the aneurysm, cause of death, and if the diagnosis was reached during life. Age was analysed by Mann-Whitney test, and the other variables by chi-square or Fisher's exact test. Multiple aneurysms corresponded to 14% of cases. The proportion of women among patients with multiple aneurysms was higher than among those with single aneurysm (64.3% versus 20.9%, P<.01), even if only cases with atherosclerosis were taken into consideration (women among multiple-6/10, 60.0%; among single-14/70, 20.0%; P=.01). Smoking was less reported in cases with multiple (4/14, 28.6%) than with single aneurysm (53/86, 61.6%; P=.04); considering cases with atherosclerosis, such difference decreases (40.0% of multiple versus 68.6% of single, P=.09). although atherosclerosis is present in most cases of both single and multiple aortic aneurysms, male gender and smoking, considered highly influential in such lesions, are less frequent in patients with multiple than in patients with single aneurysms. Thus mechanisms underlying multiple aortic aneurysms are probably different from those related to single, more common aneurysms. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. The Influence of Preoperative Aneurysmal Thrombus Quantity and Distribution on the Development of Type II Endoleaks with Aneurysm Sac Enlargement After EVAR of AAA

    Energy Technology Data Exchange (ETDEWEB)

    Müller-Wille, R., E-mail: rene.mueller-wille@ukr.de [University Medical Center Regensburg, Department of Radiology (Germany); Güntner, O., E-mail: oliverguentner@yahoo.de [Dr. Neumaier MVZ GmBH Castra Regina Center (Germany); Zeman, F., E-mail: florian.zeman@ukr.de [University Medical Center Regensburg, Center for Clinical Studies (Germany); Dollinger, M., E-mail: Dollinger-M@ukw.de [University Hospital of Würzburg, Department of Diagnostic and Interventional Radiology (Germany); Hälg, C., E-mail: haelg@gmx.ch [Kantonsspital Schaffhausen, Department of Radiology and Nuclear Medicine (Switzerland); Beyer, L. P., E-mail: lukas.beyer@ukr.de [University Medical Center Regensburg, Department of Radiology (Germany); Pfister, K., E-mail: karin.pfister@ukr.de; Kasprzak, P., E-mail: gefaess.chirurgie@ukr.de [University Medical Center Regensburg, Department of Vascular Surgery (Germany); Stroszczynski, C., E-mail: christian.stros@ukr.de; Wohlgemuth, W. A., E-mail: walter.wohlgemuth@ukr.de [University Medical Center Regensburg, Department of Radiology (Germany)

    2016-08-15

    PurposeTo determine the influence of preoperative aneurysmal thrombus quantity and distribution on the development of type II endoleak with aneurysm sac enlargement after endovascular aneurysm repair (EVAR).Materials and MethodsWe retrospectively analyzed the pre- and postoperatively performed CT scans of 118 patients who had follow-up imaging for at least 1 year after EVAR available. We assessed preoperative thrombus perimeter (T{sub Peri}), diameter (T{sub Dia}), cross-sectional area (T{sub CSA}), and volume (T{sub Vol}). The preoperative thrombus distribution was classified into no thrombus, semilunar-shaped (anterior, right side, left side, posterior) thrombus, and circumferential type thrombus. The number of preoperative patent aortic side branches (ASB) was identified. Endpoint was type II endoleak with aneurysm volume (A{sub Vol}) increase of ≥5 % during follow-up.ResultsDuring follow-up (2 years, range 1–9 years), 17 patients with type II endoleak had significant A{sub Vol} increase. Less preoperative T{sub Peri}, T{sub Dia}, T{sub CSA}, and T{sub Vol} were associated with A{sub Vol} increase. A circumferential thrombus distribution significantly protected against aneurysm enlargement (p = 0.028). The variables with the strongest significance for A{sub Vol} increase were preoperative T{sub Vol}/A{sub Vol} ratio (OR 0.95; p = 0.037) and number of patent ASB (OR 3.52; p < 0.001).ConclusionA low preoperative T{sub Vol}/A{sub Vol} ratio and a high number of patent ASB were associated with aneurysm sac enlargement after EVAR.

  3. Prevention and management of intraprocedural rupture of intracranial aneurysm with detachable coils during embolization

    International Nuclear Information System (INIS)

    Li, Ming-Hua; Gao, Bu-Lang; Fang, Chun; Cheng, Ying-Sheng; Li, Yong-Dong; Wang, Jue; Xu, Guo-Ping

    2006-01-01

    Intracranial aneurysm rupture during embolization with detachable coils is reportedly among the gravest of intraprocedural complications. We present here our experiences with this outcome, and a potential intervention for managing this life-threatening complication. From April 1998 to March 2005, 284 patients with cerebral aneurysms were treated with detachable coils. Intraprocedural aneurysm rupture occurred in ten patients with a history of a previously ruptured aneurysm. In the event of intraprocedural hemorrhage, we routinely performed heparin reversal with protamine sulfate. Of the 221 patients with a previously ruptured aneurysm, intraprocedural aneurysm rupture occurred in 10 (4.5%). These ruptures were caused by a microguidewire in one patient, a microcatheter in one, over-packing in two and a coil perforation in three. In the remaining three patients the ruptures were caused by both the microcatheter and the coils. Three patients died because of aneurysm re-rupture, yielding a mortality rate of 30%. One patient presented with a slight disability in the left leg and no neurological deficits were observed in the remaining six patients. Intraprocedural aneurysm rupture during embolization is a rare, but unavoidable and life-threatening event. Proper measures should be taken to reduce and improve the outcome of this tragic occurrence. The majority of patients with an intraprocedural ruptured aneurysm can survive without severe sequelae if managed appropriately. (orig.)

  4. Aneurysm shape reconstruction from biplane angiograms in the ISUIA collection

    NARCIS (Netherlands)

    Raghavan, Madhavan L; Sharda, Gaurav V; Huston, John; Mocco, J; Capuano, Ana W; Torner, James C; Saha, Punam K; Meissner, Irene; Brown, Robert D; Groen, Rob

    The International Study of Unruptured Intracranial Aneurysms (ISUIA) is an epidemiologic international study of the natural history of unruptured intracranial aneurysms that enrolled 4,060 subjects. A conventional biplane cerebral angiogram available for central review was required for enrollment

  5. Endovascular treatment of wide-necked aneurysms using stents combined with electrolytic detachable coils in a canine model

    International Nuclear Information System (INIS)

    Liu Jianmin; Zhang Xin; Zhou Xiaoping; Hong Bo; Xu Yi; Huang Qinghai; Zhang Long; She Jiagui; Zhao Rui

    2004-01-01

    Objective: To assess hemodynamics and histology of the aneurysms by treating experimental wide-necked aneurysms endovascularly with a combination of stents and electrolytic detachable coils. Methods: An experimental model was surgically constructed in the necks of six canines for simulating intracranial wide-necked aneurysms. Balloon-expandable metal stents were positioned across the aneurysms in bilateral carotid arteries of six canines with additional intraaneurysmal placement of detachable microcoils in only unilateral carotid artery of each canine. Sonography and angiography were performed in different stages and histologic examinations were achieved finally. Results: Stent placement was successful in all six canines. Aneurysms treated with only stents placement showed no significant thrombus formation with slow growing of neointima over the neck of the aneurysm. Thrombosis occurred in the aneurysms treated with stents and coils in a short time and neointima covered the neck of the aneurysms completely. Conclusions: Endovascular treatment of wide-necked aneurysms using stents combined with electrolytic detachable coils may prevent re-rupture of the aneurysms and promote neointima formation over the neck of the aneurysms. (authors)

  6. A nursing case history: the patient with mycotic aneurysm secondary to endocarditis.

    Science.gov (United States)

    Leith, B; Furimsky, I

    1995-03-01

    Due to the advent of antibiotics, mycotic aneurysms, also known as infective aneurysms, now represent only 2.5-5% of all aneurysms. The existing research on this topic is old and scarce. It is highly probably that a neuroscience nurse will care for this type of patient at some point during his/her career. The patient with a mycotic aneurysm is usually critically ill. A 46% mortality has been noted and is related to the multiple problems of these types of patients. Currently, if and when to surgically intervene is controversial. The case of "Mr. C.", a patient at the Montreal Neurological Hospital who developed a mycotic aneurysm secondary to subacute bacterial endocarditis, will be presented. His course in hospital, the medical management and treatment as well as the nursing care and educational needs will be described.

  7. Bilateral, Mirror-imaged, Postero-inferior Cerebellar Artery Aneurysms: Report of a Rare Case

    Directory of Open Access Journals (Sweden)

    G R Sharma

    2011-06-01

    Full Text Available A 60-year-old right-handed lady presented with the features of subarachnoid haemorrhage. The CT angiogram showed a pair of very rare bilateral, mirror-imaged distal postero-inferior cerebellar artery aneurysms. Both aneurysms were clipped via the midline posterior fossa craniectomy under general anaesthesia. The literatures is reviewed on the incidence, presentation, management and outcome of bilateral distal posterior-inferior cerebellar artery aneurysms. Keywords: bilateral mirror image, distal postero-inferior cerebellar artery aneurysms, posterior fossa craniectomy, microsurgical clipping

  8. An improved Virtual Torso phantom

    International Nuclear Information System (INIS)

    Kramer, Gary H; Crowley, Paul

    2000-01-01

    The virtual phantom that was previously designed by the Human Monitoring Laboratory had some limitations. It contained no sternum and the ribs extended all the way round the torso, whereas in reality the central part of the chest is covered with a mixture of cartilage (ribs) and bone (sternum). The ribs were located below the chest wall which added to the thickness of the chest wall. The lungs did not touch the inner surface of the chest wall along their length due to the differences in curvature between the ellipsoidal lungs and the ellipsoidal cylinder that defined the torso. As a result there was extra intervening tissue between the lungs and the chest wall. This was shown to have a noticeable effect on the simulation of low energy photons. The virtual phantom has been redesigned and comparison of measured and calculated counting efficiencies shows that it is a good representation of both of LLNL or JAERI at all photon energies measured. The redesigned virtual phantom agrees to within 11% of the torsos' counting efficiency over the energy range 17 - 240 keV. Before modification, the virtual phantom's counting efficiency was a of factor three lower at 17 keV and a factor of two lower at 20 keV; now it is within 5% at 17 keV and within 10% at 20 keV. This phantom can now be reliably used to simulate lung counting. The virtual phantom still contains no sternum and the ribs extend all the way round the torso, whereas in reality the central part of the chest is covered with cartilage (ribs) and bone (sternum). However, the above results indicate that this is not a major flaw in the design of the virtual phantom, as agreement between the Monte Carlo results and experimental data is good. (author)

  9. Microsurgical one-stage treatment of intracranial mirror aneurysms via bilateral frontolateral approaches

    Directory of Open Access Journals (Sweden)

    Hong-guang WANG

    2016-08-01

    Full Text Available Objective To investigate surgical strategies, clinical effects and complications of microsurgical one-stage treatment of intracranial mirror aneurysms via bilateral frontolateral approaches.  Methods Review clinical data of 18 cases with anterior circulation mirror aneurysms who underwent one-stage clipping via bilateral frontolateral approaches from July 2010 to July 2015 admitted to Department of Neurosurgery in Tianjin Huanhu Hospital. The operative efficacy was evaluated according to postoperative Glasgow Outcome Scale (GOS.  Results The 36 aneurysms in 18 patients were successfully clipped via bilateral frontolateral approaches at one-stage, including 18 posterior communicating artery (PCoA mirror aneurysms in 9 cases and 18 middle cerebral artery (MCA mirror aneurysms in 9 cases. GOS score of 5 was discovered in 16 cases, and 4 was discovered in 2 cases after operation. One case underwent ventriculoperitoneal shunting (VPS due to communicating hydrocephalus, one case got postoperative pulmonary infection and no death occurred. Intracranial CTA at 6 months postoperatively showed aneurysms of 18 patients were clipped completely, the parent artery blood flow was smooth, and no recurrence was found.  Conclusions Microsurgical one-stage clipping via bilateral frontolateral approaches for treating intracranial mirror aneurysms is a sugrical method with small incision, fitting surgical field, high safety, satisfactory effect and good prognosis, which is a new minimally invasive neurosurgical technique. DOI: 10.3969/j.issn.1672-6731.2016.08.012

  10. Open Versus Endovascular Stent Graft Repair of Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Firwana, Belal; Ferwana, Mazen; Hasan, Rim

    2014-01-01

    We performed an analysis to assess the need for conducting additional randomized controlled trials (RCTs) comparing open and endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA). Trial sequential analysis (TSA) is a statistical methodology that can calculate the required inform...

  11. Size ratio performance in detecting cerebral aneurysm rupture status is insensitive to small vessel removal.

    Science.gov (United States)

    Lauric, Alexandra; Baharoglu, Merih I; Malek, Adel M

    2013-04-01

    The variable definition of size ratio (SR) for sidewall (SW) vs bifurcation (BIF) aneurysms raises confusion for lesions harboring small branches, such as carotid ophthalmic or posterior communicating locations. These aneurysms are considered SW by many clinicians, but SR methodology classifies them as BIF. To evaluate the effect of ignoring small vessels and SW vs stringent BIF labeling on SR ruptured aneurysm detection performance in borderline aneurysms with small branches, and to reconcile SR-based labeling with clinical SW/BIF classification. Catheter rotational angiographic datasets of 134 consecutive aneurysms (60 ruptured) were automatically measured in 3-dimensional. Stringent BIF labeling was applied to clinically labeled aneurysms, with 21 aneurysms switching label from SW to BIF. Parent vessel size was evaluated both taking into account, and ignoring, small vessels. SR was defined accordingly as the ratio between aneurysm and parent vessel sizes. Univariate and multivariate statistics identified significant features. The square of the correlation coefficient (R(2)) was reported for bivariate analysis of alternative SR calculations. Regardless of SW/BIF labeling method, SR was equally significant in discriminating aneurysm ruptured status (P analysis of alternative SR had a high correlation of R(2) = 0.94 on the whole dataset, and R = 0.98 on the 21 borderline aneurysms. Ignoring small branches from SR calculation maintains rupture status detection performance, while reducing postprocessing complexity and removing labeling ambiguity. Aneurysms adjacent to these vessels can be considered SW for morphometric analysis. It is reasonable to use the clinical SW/BIF labeling when using SR for rupture risk evaluation.

  12. Surgical treatment of celiomesenteric trunk aneurysm-7 case report.

    Science.gov (United States)

    Wang, Chunxi; Cai, Xiangjun; Liang, Faqi; Chu, Futao; Chen, Gang; Duan, Zhiquan

    2014-01-01

    The celiomesenteric trunk is a rare anomaly characterized by a common origin of the celiac axis and superior mesenteric artery from the aorta, which accounts for less than 1% of all celiac artery anomalies, so the aneurysm occurred in such trunk is even rarer. There have been few reports on how to diagnose and deal with such malformed celiomesenteric trunk aneurysms till now. This paper tries to summarize the experience of how to expose and excise such kind of aneurysm according to the seven cases' data. The clinic data were collected retrospectively. There were seven cases with celiomesenteric trunk aneurysm from February 2000 to February 2013, including 5 males and 2 females aged 35~62. The operations were done including aneurysm resection and vascular reconstruction under general anesthesia. The operated patients were followed-up at the sixth month and each year post operation. The vascular stomas were detected or examined by Color Doppler Sonography, spiral Computed Tomography angiography (SCTA). The seven operated patients were cured and discharged from hospital, and they were followed up for 3~10 years (mean time 5 years), with four patients being followed up longer than 5 years. No sign of intestinal ischemia or hepatic ischemia or splenic ischemia was found, and no image of anastomosis stricture or stenosis was found during the follow-up. Five patients are alive now while two patients were dead, with one dying of large area myocardial infarction unexpectedly at 6 years post operation and the other dying of cerebral infarction abruptly at 4 years post operation. It is an effective and safe method to treat the celiomesenteric trunk aneurysm by using by-pass operation with artificial blood vessels, originating from inferior kidney aorta to visceral arteries including hepatic artery, splenic artery and superior mesenteric artery. Its short-term and middle-term effects are relatively better.

  13. A mycotic pulmonary artery aneurysm associated with candida endocarditis: Case report

    International Nuclear Information System (INIS)

    Moon, Jin Il; Lee, Ji Won; Jeong, Yeon Joo; Song, Seung Hwan

    2014-01-01

    We report a case of a mycotic pulmonary aneurysm associated with Candida endocarditis in a 53-year-old male with lymphoma. The initial diagnosis was a pulmonary artery aneurysm attributable to vasculitis, such as that associated with Behcet's disease, but a mycotic pulmonary artery aneurysm was later considered as a differential diagnosis. Identification of valve vegetation on the chest CT was helpful in this regard. We review the literature on the disease etiology, radiological findings, and management options.

  14. Endovascular Aneurysm Repair and Sealing (EVARS): A Useful Adjunct in Treating Challenging Morphology

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Gareth J., E-mail: garethjamesharrison@yahoo.co.uk; Antoniou, George A., E-mail: antoniou.ga@hotmail.com; Torella, Francesco, E-mail: francesco.torella@rlbuht.nhs.uk; McWilliams, Richard G., E-mail: richard.mcwilliams@rlbuht.nhs.uk; Fisher, Robert K., E-mail: robert.fisher@rlbuht.nhs.uk [Royal Liverpool University Hospital, Liverpool Vascular and Endovascular Service (United Kingdom)

    2016-04-15

    An 81-year-old male with previous open abdominal aortic aneurysm repair presented with asymptomatic large pseudoaneurysms at both ends of an open surgical tube graft. Endovascular aneurysm sealing (EVAS) in combination with the iliac limbs of a standard endovascular aneurysm repair (EVAR) successfully excluded both pseudoaneurysms from circulation. We describe the combination of elements of EVAS and EVAR and have termed this endovascular aneurysm repair and sealing (EVARS). EVARS has the advantage of harnessing the benefits of endobag sealing in aortic necks unsuitable for standard EVAR whilst providing the security of accurate stent placement within short common iliac arteries. In conclusion, EVAS may be combined with standard endovascular iliac limbs and is a possible treatment option for pseudoaneurysm following open aneurysm repair.

  15. Dissecting aneurysms of posterior communicating artery itself: anatomical, diagnostic, clinical, and therapeutical considerations.

    Science.gov (United States)

    Kocak, Burak; Tureci, Ercan; Kizilkilic, Osman; Islak, Civan; Kocer, Naci

    2013-09-01

    Posterior communicating artery (PCoA) itself is an unusual location for intracranial aneurysms in that isolated dissections or dissecting aneurysms are extremely rare. In the way of correct diagnosis of dissecting aneurysms of PCoA itself, a proper understanding of (1) the anatomy of the PCoA and its perforator branches, (2) some particular diagnostic features, and (3) related clinical aspects is of significant importance. Although there are no established treatment strategies for this particular type of aneurysms, the endovascular approach might be considered as a plausible one. In this paper, our scope was to report five cases with dissecting aneurysm of the PCoA itself and to discuss this rare vascular pathology from anatomical, diagnostic, clinical, and therapeutical perspectives.

  16. Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.

    Science.gov (United States)

    Galiñanes, Edgar Luis; Hernandez-Vila, Eduardo A; Krajcer, Zvonimir

    2015-02-01

    After abdominal aortic aneurysm repair, progressive degeneration of the aneurysm can be challenging to treat. Multiple comorbidities and previous operations place such patients at high risk for repeat surgery. Endovascular repair is a possible alternative; however, challenging anatomy can push the limits of available technology. We describe the case of a 71-year-old man who presented with a 5.3-cm pararenal aneurysm 4 years after undergoing open abdominal aortic aneurysm repair. To avoid reoperation, we excluded the aneurysm by endovascular means, using visceral-artery stenting, a chimney-graft technique. Low-profile balloons on a monorail system enabled the rapid exchange of coronary wires via a buddy-wire technique. This novel approach facilitated stenting and simultaneous angioplasty of multiple visceral vessels and the abdominal aorta.

  17. Giant partially thrombosed 4 th ventricular posterior inferior cerebellar artery aneurysm; microsurgical management

    Directory of Open Access Journals (Sweden)

    Forhad Hossain Chowdhury

    2014-01-01

    Full Text Available A 42-year-old woman presented with a 3-month history of progressive occipital headache, vomiting, walking difficulty, and repeated fall. She had no history of sudden and severe headache. She had positive cerebellar signs, predominantly on the right side. Computerized tomography (CT scan, CT angiogram, and magnetic resonance image (MRI of the brain showed suspected partially thrombosed giant 4 th ventricular posterior inferior cerebellar artery aneurysm. Patient developed severe hypersensitivity reaction during both CT scan and MRI after contrast injection. Though needed, digital subtraction angiogram (DSA of cerebral vessels was not done. The aneurysm was managed by microsurgical clipping of the aneurysm neck and partial excision of thrombosed aneurysm. Here, we report the details of management of these difficult giant aneurysm without DSA.

  18. Comparison of methods for individualized astronaut organ dosimetry: Morphometry-based phantom library versus body contour autoscaling of a reference phantom

    Science.gov (United States)

    Sands, Michelle M.; Borrego, David; Maynard, Matthew R.; Bahadori, Amir A.; Bolch, Wesley E.

    2017-11-01

    One of the hazards faced by space crew members in low-Earth orbit or in deep space is exposure to ionizing radiation. It has been shown previously that while differences in organ-specific and whole-body risk estimates due to body size variations are small for highly-penetrating galactic cosmic rays, large differences in these quantities can result from exposure to shorter-range trapped proton or solar particle event radiations. For this reason, it is desirable to use morphometrically accurate computational phantoms representing each astronaut for a risk analysis, especially in the case of a solar particle event. An algorithm was developed to automatically sculpt and scale the UF adult male and adult female hybrid reference phantom to the individual outer body contour of a given astronaut. This process begins with the creation of a laser-measured polygon mesh model of the astronaut's body contour. Using the auto-scaling program and selecting several anatomical landmarks, the UF adult male or female phantom is adjusted to match the laser-measured outer body contour of the astronaut. A dosimetry comparison study was conducted to compare the organ dose accuracy of both the autoscaled phantom and that based upon a height-weight matched phantom from the UF/NCI Computational Phantom Library. Monte Carlo methods were used to simulate the environment of the August 1972 and February 1956 solar particle events. Using a series of individual-specific voxel phantoms as a local benchmark standard, autoscaled phantom organ dose estimates were shown to provide a 1% and 10% improvement in organ dose accuracy for a population of females and males, respectively, as compared to organ doses derived from height-weight matched phantoms from the UF/NCI Computational Phantom Library. In addition, this slight improvement in organ dose accuracy from the autoscaled phantoms is accompanied by reduced computer storage requirements and a more rapid method for individualized phantom generation

  19. Ten-Year Experience with Surgical Repair of Mycotic Aortic Aneurysms

    Directory of Open Access Journals (Sweden)

    I-Ming Chen

    2005-06-01

    Conclusion: Mycotic aneurysm of the aorta is a life-threatening disease, especially when rupture occurs. The high mortality rate is due not only to the high rupture rate, but also to sepsis. When mycotic aortic aneurysm is diagnosed, early surgical intervention is mandatory.

  20. Deep neural network-based computer-assisted detection of cerebral aneurysms in MR angiography.

    Science.gov (United States)

    Nakao, Takahiro; Hanaoka, Shouhei; Nomura, Yukihiro; Sato, Issei; Nemoto, Mitsutaka; Miki, Soichiro; Maeda, Eriko; Yoshikawa, Takeharu; Hayashi, Naoto; Abe, Osamu

    2018-04-01

    The usefulness of computer-assisted detection (CAD) for detecting cerebral aneurysms has been reported; therefore, the improved performance of CAD will help to detect cerebral aneurysms. To develop a CAD system for intracranial aneurysms on unenhanced magnetic resonance angiography (MRA) images based on a deep convolutional neural network (CNN) and a maximum intensity projection (MIP) algorithm, and to demonstrate the usefulness of the system by training and evaluating it using a large dataset. Retrospective study. There were 450 cases with intracranial aneurysms. The diagnoses of brain aneurysms were made on the basis of MRA, which was performed as part of a brain screening program. Noncontrast-enhanced 3D time-of-flight (TOF) MRA on 3T MR scanners. In our CAD, we used a CNN classifier that predicts whether each voxel is inside or outside aneurysms by inputting MIP images generated from a volume of interest (VOI) around the voxel. The CNN was trained in advance using manually inputted labels. We evaluated our method using 450 cases with intracranial aneurysms, 300 of which were used for training, 50 for parameter tuning, and 100 for the final evaluation. Free-response receiver operating characteristic (FROC) analysis. Our CAD system detected 94.2% (98/104) of aneurysms with 2.9 false positives per case (FPs/case). At a sensitivity of 70%, the number of FPs/case was 0.26. We showed that the combination of a CNN and an MIP algorithm is useful for the detection of intracranial aneurysms. 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:948-953. © 2017 International Society for Magnetic Resonance in Medicine.