WorldWideScience

Sample records for aneurysm coiling role

  1. MR angiography after coiling of intracranial aneurysms

    OpenAIRE

    Schaafsma, J.D.

    2012-01-01

    Introduction Endovascular occlusion with detachable coils has become an alternative treatment to neurosurgical clipping of intracranial aneurysms over the last two decades. Its minimal invasiveness is the most important advantage of this treatment compared to clipping. The disadvantage of occlusion with coils is an approximately 20% risk of reopening of the aneurysm as a result of coil impaction, dissolution of thrombus, or growth of the aneurysm and 10% of coiled patients need additional tre...

  2. Hemodynamic performance of coil embolization and stentassisted coil embolization treatments: a numerical comparative study based on subject-specific models of cerebral aneurysms

    Science.gov (United States)

    Wang, Shengzhang; Zhang, Yisen; Lu, Gang; Yang, Xinjian; Zhang, Xiaolong; Ding, Guanghong

    2011-11-01

    Hemodynamic characteristics such as blood velocity, blood pressure, flow impingement, wall shear stress and oscillatory shear index are considered to play important roles in the initiation, growth, rupture and recurrence of the cerebral aneurysms. Endovascular therapy is widely implemented to treat the cerebral aneurysms by releasing coils into the aneurysm sac for limiting the blood flow to the sac and stent-assisted coil embolization is adopted to occlude the wide-necked or complex aneurysms. Some researchers believe that stents are not only a mechanical device but may act as a biological system and contribute to vessel wall healing. Hemodynamics simulation helps people understand the effect of hemodynamic characteristics on the recurrence of the coiled aneurysm and it also benefits the interventional planning of neurosurgeons. This study constructed the numerical model for a subject-specific ICA aneurysm treated with stent-assisted coil embolization, which combined the coiled model of the aneurysm with a porous stent placement, and simulated the pulsatile blood flow in these aneurysm models. When a stent was placed across the aneurysm orifice in the coiled aneurysm, the high wall shear stress around the distal aneurysm root was reduced more than that of the coiled aneurysm without a stent. The simulated results point to the conclusion that the stent not only protects the parent artery from occlusion due to extension of coils or thrombosis, but may also reduce the recurrence risk of the stent-assisted coiled aneurysm.

  3. Endovascular coil embolization of aneurysm neck for the treatment of ruptured intracranial aneurysm with bleb formation

    OpenAIRE

    Wan, Jun; Gu, Weijin; Zhang, Xiaolong; Geng, Daoying; Lu, Gang; Huang, Lei; Zhang, Lei; Ge, Liang; Ji, Lihua

    2014-01-01

    Background Ruptured intracranial aneurysm (ICA) with bleb formation (RICABF) is a special type of ruptured ICA. However, the exact role and effectiveness of endovascular coil embolization (ECE) in RICABF is unknown. We aimed to investigate the effectiveness and safety of ECE of aneurysm neck for RICABF treatment. Material/Methods We retrospectively assessed consecutive patients who were hospitalized in our endovascular intervention center between October 2004 and May 2012. Overall, 86 patient...

  4. The Influence of Dome Size, Parent Vessel Angle, and Coil Packing Density on Coil Embolization Treatment in Cerebral Aneurysms

    Science.gov (United States)

    Frakes, David H.; Indahlastari, Aprinda; Ryan, Justin; Babiker, M. Haithem; Nair, Priya; Parthas, Varsha

    2013-11-01

    Intracranial aneurysms (ICAs) are dilated cerebral blood vessels. Treating ICAs effectively prior rupture is crucial since their association with 45% mortality rate. Embolic coiling is the most effective ICA treatment. Series of embolic coils are deployed into the aneurysm with the intent of reaching a sufficient packing density (PD) to help seal off the ICA from circulation. While coiling is effective, treatment failures have been associated with basilar tip aneurysms (BTAs), perhaps because of their geometry. The aim of this study was to examine the effect of dome size, parent vessel (PV) angle, and PD on intraaneurysmal (IA) velocity, crossneck (CN) flow and low wall shear stress (WSS) area using simulations and experiments in idealized BTA models. IA velocity and CN flow decreased after coiling, while low WSS area increased. With increasing PD, IA velocity and CN flow were further reduced, but low WSS area had a minimal change. Coil PD had the greatest impact on post-treatment flow while dome size had a greater impact than PV angle. Overall, the role of aneurysmal geometries may vary depending on treatment goal and timing e.g., high coil PD may reduce IA velocity more effectively during early aneurysmal growth when the dome size is small. Funded by the American Heart Association.

  5. Aneurysmal subarachnoid hemorrhage: outcome of aneurysm clipping versus coiling in anterior circulation aneurysm

    International Nuclear Information System (INIS)

    To compare the neurological outcome of microsurgical clipping versus coiling in patients with anterior circulation aneurysm. Study Design: Comparative study. Place and Duration of Study: Department of Neurosurgery, Lahore General Hospital, Lahore, from January 2010 to December 2013. Methodology: Patients aged 14 - 60 years, with ruptured cerebral aneurysm of anterior circulation and World Federation of Neurosurgical Society (WFNS) grades 1, 2 and 3 were included. Patients more than 60 years, medically unfit patient and posterior circulation aneurysms and WFNS grades 4 and 5 were excluded. Aneurysm sac obliteration was done in randomized manner with microsurgical clipping or coiling. Postoperatively, the patients were assessed and followed-up upto one year for outcome parameters on the bases of WFNS grade and Modified Ranking Scale (mRS) as favourable (mRS =2 ) and unfavourable (mRS > 2). Results: Among 140 subjects selected for study, 70 were included in group A, i.e. coiling and other 70 were in group B, i.e. clipping. The median age of patients in group A was 52.5 ± 10 years and in group B was 51.00 ± years. Overall, 56 (40%) males, 28 (60%) males in each group; and 84 (60%) females, 42 (60%) in each group were included. The male to female ratio in this study was 1:1.5. In group A, i.e. coiling, 27 (38.6%) patients had no disability (grades 1 and 2), 25 (35.7%) were slightly disabled (grade 3) and 18 (25.7%) had moderate disability (grade 4); whereas in group B, i.e. clipping group 23 (32.9%) patients had no disability (grades 1 and 2), 23 (32.9%) were slightly disabled (grade 3) and 24 (34.3%) had moderate disability (grade 4). At one year follow-up, in group A, favourable outcome was achieved in 56 (80%) of patients compared to 48 (68.6%) in group B; whilst, 14 (20%) patients in group A and 22 (33.1%) in group B showed unfavourable outcome. Although mortality rate was higher in clipping (n=3, 4.3%) as compared to coiling (n=1, 1.4%), but was not statistically

  6. COMPLICATION ANALYSIS OF INTRACRANIAL ANEURYSM EMBOLIZATION WITH CONTROLLABLE COILS

    Institute of Scientific and Technical Information of China (English)

    王大明; 凌锋; 王安顺

    2004-01-01

    Objective To explore the causes, prevention, and management of the complications during intracranial aneurysm embolization with controllable coils (mechanical detachable spiral, MDS; and Guglielmi detachable coil, GDC). Methods Retrospective review of 120 cases with 125 intracranial aneurysms embolized with controllable coils from March 1995 to July 1999 was conducted. The 20 accidents (in 18 cases) including aneurysm rupture, over-embolization, protrusion of coil end into the parent artery, and thrombosis of the parent artery were analyzed. Results Among the 20 accidents, there were 6 aneurysm ruptures, 6 over-embolizations (in 5cases), 6 coil protrusions, and 2 thromboses (one was secondary to coil protrusion). The embolizationrelated mortality was 3.33% (4/120), the permanent neurological deficit was 1.67% (2/120), and the transitory neurological deficit was 3.33% (4/120). The occurrence and outcome of the complications were related to the embolizing technique, the pattern of aneurysm and its parent artery, the imperfection of embolic materials, and the observation and management during embolization. Conclusion Skilled embolizing technique, better understanding of the angio-anatomy of an aneurysm and its parent artery, correct judgement and management during embolization, and improvement of embolic materials are beneficial to the reduction of complications and to the melioration of the outcome of complications.

  7. Coil embolization of mycotic pulmonary artery aneurysm: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeen Woo; Lee, Jae Kyo; Hwang, Mi Soo; Cho, Kil Ho [College of Medicine, Yeungnam University, Taegu (Korea, Republic of)

    2000-02-01

    Aneurysms of the pulmonary artery are rare, with mycotic aneurysms occurring most frequently. This latter type may also occur in association with a lung abscess or septicemia, particularly in drug addicts. As far as we are aware, the radiologic findings of mycotic aneurysm of the pulmanary artery have not been reported in Korea. We present the simple chest radiographs, as well as the CT and angiographic findings, of a case of aneurysm of the pulmonary artery which was successfully embolized using a coil. (author)

  8. Mesenteric ischaemia after endovascular coiling of ruptured cerebral aneurysms.

    LENUS (Irish Health Repository)

    Kamel, M H

    2012-02-03

    Three patients were referred to a national neurosurgical centre following CT evidence of subarachnoid haemorrhage. The three patients, who were referred from different institutions within a seven week period, were Fisher grade 3 and WFNS Grade I at all times. Angiography showed a PCOM aneurysm in one case, a ruptured Basilar tip aneurysm and an unruptured ACOM aneurysm in another case, and an ACOM aneurysm in the third case. It was decided that the aneurysms were suitable for endovascular coiling. These patients had unremarkable intraoperative catheterizations and coiling but subsequently deteriorated post-operatively due to mesenteric ischaemia. Two patients required colectomy for mesenteric ischaemia, and the third arrested secondary to sepsis from bowel perforation. We discuss the various causes that may explain this association, and we alert the neurosurgical community for this complication which has not been reported before.

  9. Endovascular treatment of posterior cerebral artery aneurysms using detachable coils

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Hong Gee [Kangwon National University Hospital, Department of Radiology, Chuncheon, Kangwon-do (Korea); Konkuk University Hospital, Department of Radiology, Seoul (Korea); Kim, Sam Soo; Han, Heon [Kangwon National University Hospital, Department of Radiology, Chuncheon, Kangwon-do (Korea); Kang, Hyun-Seung [Konkuk University Hospital, Department of Neurosurgery, Seoul (Korea); Moon, Won-Jin [Konkuk University Hospital, Department of Radiology, Seoul (Korea); Byun, Hong Sik [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea)

    2008-03-15

    Aneurysms of the posterior cerebral artery (PCA) are rare, and most of the studies reported in the literature in which the endovascular approach was applied were carried out on a limited number of patients with PCA aneurysms. We retrospectively reviewed our cases of PCA aneurysms - at various locations and of differing shapes - that received endovascular treatment and evaluated the treatment outcome. From January 1996 to December 2006, 13 patients (eight females and five males) with 17 PCA aneurysms (nine fusiform and eight saccular) were treated using the endovascular approach. The age of the patients ranged from 20 to 67 years, with a mean age of 44 years. Of the 13 patients, ten presented with intracranial hemorrhage, and one patient, with a large P2 aneurysm, presented with trigeminal neuralgia; the aneurysms were asymptomatic in the remaining two patients. All 13 patients were successfully treated, with only one procedure-related symptomatic complication. Seven patients were treated by occlusion of the aneurysm and parent artery together; five patients, by selective embolization of the aneurysm; one patient, by partial coiling. Although infarctions were found in two patients treated with selective embolization and in three patients treated with parent artery occlusion, only one patient with a ruptured P2 aneurysm treated with parent artery occlusion developed transient amnesia as an ischemic symptom. Posterior cerebral artery aneurysms can be treated safely with either occlusion of the aneurysm together with the PCA or with a selective coil embolization. Infarctions may occur after endovascular treatment, but they are rarely the cause of a disabling symptom. (orig.)

  10. Endovascular treatment of posterior cerebral artery aneurysms using detachable coils

    International Nuclear Information System (INIS)

    Aneurysms of the posterior cerebral artery (PCA) are rare, and most of the studies reported in the literature in which the endovascular approach was applied were carried out on a limited number of patients with PCA aneurysms. We retrospectively reviewed our cases of PCA aneurysms - at various locations and of differing shapes - that received endovascular treatment and evaluated the treatment outcome. From January 1996 to December 2006, 13 patients (eight females and five males) with 17 PCA aneurysms (nine fusiform and eight saccular) were treated using the endovascular approach. The age of the patients ranged from 20 to 67 years, with a mean age of 44 years. Of the 13 patients, ten presented with intracranial hemorrhage, and one patient, with a large P2 aneurysm, presented with trigeminal neuralgia; the aneurysms were asymptomatic in the remaining two patients. All 13 patients were successfully treated, with only one procedure-related symptomatic complication. Seven patients were treated by occlusion of the aneurysm and parent artery together; five patients, by selective embolization of the aneurysm; one patient, by partial coiling. Although infarctions were found in two patients treated with selective embolization and in three patients treated with parent artery occlusion, only one patient with a ruptured P2 aneurysm treated with parent artery occlusion developed transient amnesia as an ischemic symptom. Posterior cerebral artery aneurysms can be treated safely with either occlusion of the aneurysm together with the PCA or with a selective coil embolization. Infarctions may occur after endovascular treatment, but they are rarely the cause of a disabling symptom. (orig.)

  11. Mechanisms of Healing in Coiled Intracranial Aneurysms: A Review of the Literature

    Science.gov (United States)

    Brinjikji, Waleed; Kallmes, David F; Kadirvel, Ramanathan

    2016-01-01

    Summary Recanalization of intracranial aneurysms following endovascular coiling remains a frustratingly common occurrence. An understanding of the molecular and histopathological mechanisms of aneurysm healing following coil embolization is essential to improving aneurysm occlusion rates. Histolopathologic studies in coiled human and experimental aneurysms suggest that during the first month post-coiling, thrombus formation and active inflammation occur within the aneurysm dome. Several months following embolization, the aneurysm is excluded from the parent vessel by formation of a neointimal layer, which is often thin and discontinuous, across the aneurysm neck. Numerous coil modifications and systemic therapies have been tested in animals and humans in an attempt to improve the aneurysm healing process; these modifications have met with variable levels of success. In this review, we summarize the histopathologic and molecular biology of aneurysm healing and discuss how these findings have been applied in an attempt to improve angiographic outcomes in patients harboring intracranial aneurysm. PMID:25430855

  12. Endovascular coil embolization in internal carotid artery bifurcation aneurysms

    International Nuclear Information System (INIS)

    Aim: To present the clinical and radiological results of coil embolization in internal carotid artery (ICA) bifurcation aneurysms (BA). Materials and methods: The records of 65 patients with 66 ICA BA were retrieved from data prospectively accrued between September 1999 and July 2013. Clinical and morphological outcomes of the aneurysms were assessed, including technical aspects of treatment. Results: The aneurysms under study were directed either superiorly (41/66, 62.1%), anteriorly (24/66, 36.4%), or posteriorly (1/66, 1.5%), and all were devoid of perforators. Aneurysmal necks were situated symmetrically at the terminal ICA (37/66, 56.1%) or slightly deviated to the proximal A1 segment (29/66, 43.9%). The steam-shaped S microcatheter (73.8%) was most commonly used to select the aneurysms, and the single microcatheter technique was most commonly applied (56.1%) to perform coil embolization, followed by balloon remodelling (21.2%), multiple microcatheter (15.1%), and stent-protection (7.6%). Successful aneurysmal occlusion was achieved in 100% of cases, with no procedure-related morbidity or mortality. Imaging performed in the course of follow-up (mean duration 27.3 months) confirmed stable occlusion of most lesions (47/53, 88.7%). Conclusion: Through tailored technical strategies, ICA BA are amenable to safe and effective endovascular coil embolization, with a tendency for stable occlusion long-term

  13. Microcatheter looping to facilitate aneurysm selection in coil embolization of paraclinoid aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Dae; Rhim, Jong Kook; Park, Jeong Jin; Jeon, Jin Sue; Yoo, Roh Eul; Kang, Hyun Seung; Kim, Jeong Eun; Cho, Won Sang; Han, Moon Hee [Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2015-08-15

    Described herein is a microcatheter looping technique to facilitate aneurysm selection in paraclinoid aneurysms, which remains to be technically challenging due to the inherent complexity of regional anatomy. This retrospective study was approved by our Institutional Review Board, and informed consent was waived. Microcatheter looping method was employed in 59 patients with paraclinoid aneurysms between January 2012 and December 2013. In the described technique, construction of a microcatheter loop, which is steam-shaped or pre-shaped, based on the direction of aneurysms, is mandatory. The looped tip of microcatheter was advanced into distal internal carotid artery and positioned atop the target aneurysm. By steering the loop (via inner microguidewire) into the dome of aneurysm and easing tension on the microcatheter, the aneurysm was selected. Clinical and morphologic outcomes were assessed with emphasis on technical aspects of the treatment. Through this looping technique, a total of 59 paraclinoid aneurysms were successfully treated. After aneurysm selection as described, single microcatheter technique (n = 25) was most commonly used to facilitate coiling, followed by balloon protection (n = 21), stent protection (n = 7), multiple microcatheters (n = 3), and stent/balloon combination (n = 3). Satisfactory aneurysmal occlusion was achieved through coil embolization in 44 lesions (74.6%). During follow-up of 53 patients (mean interval, 10.9 ± 5.9 months), only one instance (1.9%) of major recanalization was observed. There were no complications related to microcatheter looping. This microcatheter looping method facilitates safe and effective positioning of microcatheter into domes of paraclinoid aneurysms during coil embolization when other traditional microcatheter selection methods otherwise fail.

  14. Interventional coil embolization for micro-intracranial aneurysms and the midterm follow-up

    International Nuclear Information System (INIS)

    Objective: To discuss the coiling embolization techniques for micro-intracranial aneurysm, and evaluate the clinical efficacy and midterm follow-up. Methods: From 2004 to 2007, 19 patients with 20 ruptured micro-intracranial aneurysms underwent coil embolization in our institution, including simple coil embolization in 9 aneurysms, stent-assisted coil embolization in 9 and balloon-assisted coil embolization in 2. Results: All aneurysms were successfully embolized with coils. Angiography immediately after coiling procedure revealed complete occlusion in 5 aneurysms, neck remnant in 9 and residual aneurysm in 6. In 3 cases, coil can't be completely packed into the aneurysm and was left in the parent artery. Coil/stent displacement and acute thrombosis were not found. Over 1-year follow-up, aneurysm re-rupture was not found. Seventeen patients recovered without neurologic complications, the other two consisted of 1 with mild hemiparalysis and 1 with oculomotor paresis. The follow-up angiography 1 year after coiling showed complete occlusion in 15 aneurysms, neck remnant in 4 and residual aneurysm enlargement in 1. Conclusion: Coil embolization for ruptured micro-intracranial anerysm is safe and efficient, and selection of suitable coiling technique is the key to treatment. (authors)

  15. Comparison of the association of sac growth and coil compaction with recurrence in coil embolized cerebral aneurysms.

    Directory of Open Access Journals (Sweden)

    Anna L Hoppe

    Full Text Available In recurrent cerebral aneurysms treated by coil embolization, coil compaction is regarded as the presumptive mechanism. We test the hypothesis that aneurysm growth is the primary recurrence mechanism. We also test the hypothesis that the coil mass will translate a measurable extent when recurrence occurs.An objective, quantitative image analysis protocol was developed to determine the volumes of aneurysms and coil masses during initial and follow-up visits from 3D rotational angiograms. The population consisted of 15 recurrence and 12 non-recurrence control aneurysms initially completely coiled at a single center. An investigator sensitivity study was performed to assess the objectivity of the methods. Paired Wilcoxon tests (p<0.05, one-tailed were performed to assess for aneurysm and coil growth. The translation of the coil mass center at follow-up was computed. A Mann Whitney U-Test (p<0.05, one-tailed was used to compare translation of coil mass centers between recurrence and control subjects.Image analysis protocol was found to be insensitive to the investigator. Aneurysm growth was evident in the recurrence cohort (p=0.003 but not the control (p=0.136. There was no evidence of coil compaction in either the recurrence or control cohorts (recurrence: p=0.339; control: p=0.429. The translation of the coil mass centers was found to be significantly larger in the recurrence cohort than the control cohort (p=0.047.Aneurysm sac growth, not coil compaction, was the primary mechanism of recurrence following successful coil embolization. The coil mass likely translates to a measurable extent when recurrence occurs and has the potential to serve as a non-angiographic recurrence marker.

  16. Renal artery aneurysm in a hypertensive child treated by percutaneous coil embolization

    International Nuclear Information System (INIS)

    A 16-year-old boy was admitted to our hospital with uncontrolled hypertension. A left renal artery aneurysm was detected on colour Doppler US and CT. Renal arteriography demonstrated the aneurysm and focal renal parenchymal areas of decreased perfusion. The renal artery aneurysm was successfully treated by transcatheter coil embolization. (orig.)

  17. Onyx combined with coiling embolization for endovascular treatment of complex intracranial ruptured aneurysms

    International Nuclear Information System (INIS)

    Objective: To study the therapeutic effect of Onyx combined with stent-assisted coiling in embolizing complex intracranial ruptured aneurysms. Methods: Onyx combined with stent-assisted coiling embolization was conducted in two patients with complex intracranial ruptured aneurysms. The clinical data were retrospectively analyzed. The related literature concerning intracranial complex aneurysm treated with Onyx was reviewed. Results: Two intracranial complex aneurysms were embolized with Onyx together with coils. The lesions were located at internal carotid arterial bifurcation (n=1) and at the anterior wall of internal carotid artery (n=1). Complete embolization of the aneurysms was achieved immediately after the procedure while the parent arteries remained patent. Conclusion: For the treatment of complex intracranial ruptured aneurysms Onyx combined with coiling embolization is safe, effective and feasible. This technique can improve the degree of embolization. To make the evaluation of the long-term efficacy further study is needed. (authors)

  18. Endovascular Coiling of Multiple (More than Four) Intracranial Aneurysms: Case Report

    OpenAIRE

    Kim, Y J; Song, K. Y.

    2004-01-01

    The incidence of multiple intracranial aneurysms has been reported from 5% to 35%. But over four multiple aneurysms are extremely rare. Sometimes it is very difficult to draw a clear line between ruptured ones and unruptured others especially in multiple aneurysm cases with even distribution of subarachnoid haemorrhage on basal cistern. We present two cases of multiple aneurysms, more than four, which were successfully treated by endovascular coiling at the same time. Our experience suggests ...

  19. Coil embolization in precommunicating (A1) segment aneurysms of anterior cerebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Dae; Ahn, Jun Hyong; Jung, Seung Chai; Kim, Chang Hun [Seoul National University Hospital, Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Kang, Hyun-Seung; Kim, Jeong Eun [Seoul National University Hospital, Seoul National University College of Medicine, Department of Neurosurgery, 28 Yongon-dong, Jongno-gu, Seoul (Korea, Republic of); Son, Young Je [Seoul National University Boramae Hospital, Seoul National University College of Medicine, Department of Neurosurgery, Seoul (Korea, Republic of); Han, Moon Hee [Seoul National University Hospital, Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Hospital, Seoul National University College of Medicine, Department of Neurosurgery, 28 Yongon-dong, Jongno-gu, Seoul (Korea, Republic of)

    2014-03-15

    Precommunicating (A1) segment aneurysms of the anterior cerebral artery are rare and often pose technical challenges for coil embolization due to their distinctive configurations. Clinical and radiologic outcomes of treating such aneurysms through endovascular coil embolization are presented herein. Data accruing prospectively from May 2002 to August 2013 yielded 48 patients harboring 50 A1 segment aneurysms, each classified as proximal, middle, or distal by location. Clinical outcome of the patients and morphological outcome of the aneurysms were assessed, with emphasis on technical aspects of treatment. The aneurysms studied occupied either proximal (n = 39), middle (n = 6), or distal (n = 5). Proximal aneurysms were largely directed posteriorly (80 %), and most (97 %) were devoid of branches. Middle and distal aneurysms were associated with the medial lenticulostriate artery, cortical branches, or fenestrations. The preshaped ''S'' and steam-shaped ''S'' microcatheters facilitated aneurysm selection in 60 % of lesions. Single-microcatheter technique was most commonly applied for coil embolization (62 %), followed by balloon protection (16 %). Successful aneurysmal occlusion could be achieved in 76 % of the patients, with no procedure-related morbidity and mortality. At final follow-up (mean interval, 29.9 months), stable aneurysmal occlusion was sustained in 93 % of the patients (40/43). A1 segment aneurysms are amenable to safe and efficacious endovascular coil embolization by adjusting procedural strategy to accommodate distinctive anatomic configurations. (orig.)

  20. Endovascular treatment of experimental aneurysms in rabbits using Guglielmi detachable coils - a feasibility study

    International Nuclear Information System (INIS)

    The Guglielmi detachable coil (GDC) has been generally accepted for treatment of intracranial aneurysms. Preclinical testing of new coil developments requires animal models of aneurysms which imitate human aneurysms in size, configuration and neck morphology. We assessed in detail the technical requirements and steps for transfemoral treatment of experimentally induced aneurysms at the top of the brachiocephalic trunk (TBC) in rabbits. We created aneurysms in five rabbits by distal ligation and intraluminal incubation of the right common carotid artery with elastase. All animals were treated successfully 2-3 weeks after induction of the aneurysm, with dense packing of the coils. No complications related to the procedures occurred. The study demonstrates that our animal model can be a suitable method for testing the biocompatibility and occlusion rate of new embolic materials. (orig.)

  1. Tiny intracranial aneurysms: Endovascular treatment by coil embolisation or sole stent deployment

    International Nuclear Information System (INIS)

    Purpose: Tiny intracranial aneurysms pose a significant therapeutic challenge for interventional neuroradiologists. The authors report their preliminary results of endovascular treatment of these aneurysms. Methods: Between January 2002 and December 2009, 52 tiny intracranial aneurysms (defined as ≤3 mm in maximum diameter) in 46 patients (22 men; mean age, 57.9 years) were treated by endosaccular coil embolisation or sole stent deployment in the parent artery. Of 52 aneurysms, 29 had ruptured and 23 remained unruptured. The initial angiographic results, procedural complications, and clinical outcomes were assessed at discharge. Imaging follow-up was performed with cerebral angiography. Results: One aneurysm coiling procedure failed because of unsuccessful micro-catheterization. Forty-three aneurysms were successfully coil embolized, of which complete occlusion was obtained in 14, subtotal occlusion in 18 and incomplete occlusion in 11. The other 8 aneurysms were treated by sole stent deployment in the parent artery. Procedural complications (2 intraprocedural ruptures and 3 thromboembolic events) occurred in 5 (9.6%) of 52 aneurysms, resulting in permanent morbidity in only 1 (2.2%, 1/46) patient. No rebleeding occurred during clinical follow-up (mean duration, 46.7 months). Of the 16 coiled aneurysms that receiving repetitive angiography, 6 initially completely and 3 subtotally occluded aneurysms remained unchanged, 4 initially subtotally and 3 incompletely occluded aneurysms progressed to total occlusion. Five sole stent deployed aneurysms received angiographic follow-up (mean duration, 10.0 months), of which 3 remained unchanged, 1 became smaller and 1 progressed to total occlusion. Conclusion: Endovascular treatment of tiny intracranial aneurysms is technical feasible and relatively safe. Coil embolisation seems to be effective in preventing early recanalisation, whereas sole stenting technique needs further investigation to determine its effectiveness.

  2. Effect of coil embolization on blood flow through a saccular cerebral aneurysm

    Indian Academy of Sciences (India)

    Vishal Agrawal; Chandan Paul; M K Das; K Muralidhar

    2015-05-01

    Coil embolization is a mildly invasive endovascular method for treatment of a cerebral aneurysm. The presence of a coil reduces fluid loading of the blood vessel and delays further deformation of the walls. Its effectiveness depends on the coil porosity and permeability apart from the nature of flow pulsations and its geometry. In the present work, a three dimensional numerical study of pulsatile flow of blood through an artery with saccular cerebral aneurysm is reported. The flow is unsteady but is taken to be laminar and incompressible. The coil is treated as homogeneous and isotropic porous medium. A comparative study has been carried out on aneurysms with and without a coil insert considering blood as a non-Newtonian fluid. The simulation is carried out for Reynolds numbers $Re$ = 500 and 1500. Results show that the velocity magnitude within the coil embolized aneurysm becomes negligible after coil insertion. The wall shear stress within the aneurysm decreases to a great extent for both Reynolds numbers. Pressure levels remain relatively unchanged. Overall, reduced wall loading with a coil stabilizes the growth of the aneurysm and thus provides an advantage.

  3. Selective treatment of an anterior spinal artery aneurysm with endosaccular coil therapy. Case report.

    Science.gov (United States)

    Lavoie, Pascale; Raymond, Jean; Roy, Daniel; Guilbert, François; Weill, Alain

    2007-05-01

    The authors report the case of a 12-year-old boy with spinal cord arteriovenous malformation (AVM) and an associated anterior spinal artery (ASA) aneurysm treated with selective coil placement in the context of subarachnoid hemorrhage (SAH). The patient presented with headache. Head computed tomography scanning revealed no abnormal findings. The cerebrospinal fluid was sampled and analyzed and a diagnosis of SAH was established. Investigation, including magnetic resonance imaging of the cord as well as cerebral and spinal angiography, revealed a conus medullaris AVM and a saccular aneurysm located on the ASA at the T-11 level. The aneurysm was thought to be responsible for the bleeding. Superselective ASA angiography showed that the aneurysm was at the bifurcation between a large coronal artery supplying the AVM and the ASA. The relation of the aneurysm's neck to the main spinal axis and the aneurysm's morphological features indicated that the lesion was suited for endosaccular coil therapy. The aneurysm was selectively occluded, using electrodetachable bare platinum coils. Follow-up angiography immediately after surgery and at 6 months thereafter demonstrated complete occlusion of the aneurysm and a perfectly patent anterior spinal axis. On clinical follow-up examination, the patient remained neurologically intact. When the morphological features of a spinal aneurysm and its relation with the anterior spinal axis are favorable, selective endosaccular coil placement can successfully be achieved. PMID:17542515

  4. Effect of antiplatelet therapy for endovascular coiling in aneurysmal subarachnoid hemorrhage

    NARCIS (Netherlands)

    van den Bergh, Walter M; Kerr, Richard S C; Algra, Ale; Rinkel, Gabriel J E; Molyneux, Andrew J

    2009-01-01

    BACKGROUND AND PURPOSE: Antiplatelets are frequently used during or after endovascular coiling of aneurysm in patients with subarachnoid hemorrhage (SAH). This strategy is based on uncontrolled case series including also patients with unruptured aneurysms or other lesions. We collected data on effec

  5. Coil embolization of an aneurysm located at the trunk of the persistent primitive trigeminal artery.

    Science.gov (United States)

    Kai, Yutaka; Ohmori, Yuki; Watanabe, Masaki; Morioka, Motohiro; Hirano, Teruyuki; Kawano, Takayuki; Sakurama, Tomotaka; Miura, Akiko; Kuratsu, Jun-Ichi

    2011-01-01

    A 71-year-old woman presented with an aneurysm at the trunk of the persistent primitive trigeminal artery (PPTA) manifesting as subarachnoid hemorrhage. Angiography and three-dimensional computed tomography revealed a wide-necked saccular aneurysm at the trunk of the left PPTA. Coil embolization with the balloon-assist technique was successful and PPTA patency was preserved. Preoperative conventional angiography should be performed to check for cross-filling of the PPTA. This case demonstrates that an aneurysm of the trunk of the PPTA can be successfully treated by coil embolization using the balloon-assist technique. PMID:21613761

  6. Resolution of trigeminal neuralgia by coil embolization of a persistent primitive trigeminal artery aneurysm

    Science.gov (United States)

    Ladner, Travis R; Ehtesham, Moneeb; Davis, Brandon J; Khan, Imad S; Ghiassi, Mayshan; Ghiassi, Mahan; Singer, Robert J

    2013-01-01

    The persistent primitive trigeminal artery (PTA) is a rare anastomosis between the carotid artery and basilar artery. While most PTAs are asymptomatic, lateral variants can occasionally compress the trigeminal nerve and precipitate trigeminal neuralgia. Aneurysms of the PTA are exceptionally rare in the literature and have not previously been associated with trigeminal neuralgia. We present the first case of an aneurysm of the PTA causing trigeminal neuralgia. The patient underwent coil embolization of the aneurysm which relieved her symptoms. We propose embolization as a viable therapeutic option for the resolution of trigeminal neuralgia when the condition is secondary to irritation by the high velocity pulsatile flow of an aneurysm. PMID:23625680

  7. Resolution of trigeminal neuralgia by coil embolization of a persistent primitive trigeminal artery aneurysm.

    Science.gov (United States)

    Ladner, Travis R; Ehtesham, Moneeb; Davis, Brandon J; Khan, Imad S; Ghiassi, Mayshan; Ghiassi, Mahan; Singer, Robert J

    2014-04-01

    The persistent primitive trigeminal artery (PTA) is a rare anastomosis between the carotid artery and basilar artery. While most PTAs are asymptomatic, lateral variants can occasionally compress the trigeminal nerve and precipitate trigeminal neuralgia. Aneurysms of the PTA are exceptionally rare in the literature and have not previously been associated with trigeminal neuralgia. We present the first case of an aneurysm of the PTA causing trigeminal neuralgia. The patient underwent coil embolization of the aneurysm which relieved her symptoms. We propose embolization as a viable therapeutic option for the resolution of trigeminal neuralgia when the condition is secondary to irritation by the high velocity pulsatile flow of an aneurysm. PMID:24610143

  8. A Thrombus Generation Model Applied to Aneurysms Treated with Shape Memory Polymer Foam and Metal Coils

    Science.gov (United States)

    Horn, John; Ortega, Jason; Hartman, Jonathan; Maitland, Duncan

    2015-11-01

    To prevent their rupture, intracranial aneurysms are often treated with endovascular metal coils which fill the aneurysm sac and isolate it from the arterial flow. Despite its widespread use, this method can result in suboptimal outcomes leading to aneurysm recurrence. Recently, shape memory polymer foam has been proposed as an alternative aneurysm filler. In this work, a computational model has been developed to predict thrombus formation in blood in response to such cardiovascular implantable devices. The model couples biofluid and biochemical phenomena present as the blood interacts with a device and stimulates thrombus formation. This model is applied to simulations of both metal coil and shape memory polymer foam treatments within an idealized 2D aneurysm geometry. Using the predicted thrombus responses, the performance of these treatments is evaluated and compared. The results suggest that foam-treated aneurysms may fill more quickly and more completely with thrombus than coil-filled aneurysms, potentially leading to improved long-term aneurysm healing. This work was performed in part under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  9. Performance of long J-shaped coils in large and giant intracranial aneurysms: an in vitro study

    International Nuclear Information System (INIS)

    We evaluated the performance of long straight coils (Detach-18 trademark J-shaped coils) in large and giant in-vitro aneurysms. The coils consisted of a distal semicircular part 7 or 15 mm in diameter and a proximal 70 cm straight part having three types of stiffness: soft, standard, and stiff. We first investigated the ease of passage through a microcatheter in a realistic cerebral vessel model. Second, we made silicone models simulating lateral-type aneurysms of various spherical dome diameters (12, 15, 20 and 30 mm) and neck sizes (3-10 mm; dome-to-neck ratio approximately 3:1) and connected them to a pulsating circulatory pump. We evaluated the anchoring and folding patterns of the coils, stability of the microcatheter and coils in the aneurysm, and smoothness of delivery and retrieval of coils. Third, we compared the conformability of a coil in a large, irregular aneurysm with that of a spiral coil. The long J-shaped coils were easily advanced and retrieved through a microcatheter in a tortuous vessel model. In 12 mm spherical aneurysms, each coil made a complex framework, and knot formation or damage to the coil during withdrawal was often observed. In 15 mm aneurysms, the coils were all easily delivered and retrieved; standard-stiffness coils adapted best to this size. In 20 mm aneurysms, frameworks were less complex but still good with a standard or stiff coil, but those with soft coil were unstable and changed significantly within 3 min of detachment due to gravity and pulsatile flow. In 30 mm aneurysms, soft coils filled only the lower part during introduction, whereas a stiff coil still made a favourable framework. Conformability of a long J-shaped coil was superior to that of a spiral coil in a large, irregular aneurysm. Long J-shaped coils conform well to various configurations of large and giant aneurysms and can shorten procedures since a larger implant volume can be delivered with a single coil. Their principle of action may promote more favourable

  10. Coiling vs. clipping. Hospital stay and procedure time in intracranial aneurysm treatment

    International Nuclear Information System (INIS)

    Purpose: evaluation of hospital resource allocation in intracranial aneurysm treatment in a medium-volume neurovascular center. Materials and methods: retrospective data analysis included 653 procedures performed on 598 patients with 667 aneurysms (A) from 1990 to 2004. 515 treatments were carried out in ruptured A (clip: n = 370; coil: n = 145) and 138 procedures in non-ruptured A (clip: n = 51, coil: n = 87). Patient management data included procedure time (min), length of stay in the intensive care unit (days), total length of hospital stay (days), and discharge to home ratio. Results: clinical admission grade (rupt. A: Hunt and Hess grade 1-3: clip: 73% coil: 72%) and clinical outcome at discharge (good neurological outcome/mortality rate: rupt. A: clip: 51.1/13.8% coil: 45.5/10.3% non-rupt. A: 88.2/0% coil: 88.5/1.3%) were similar for both treatment modes. The coil procedure time was found to be significantly shorter (rupt. A: coil: 145 min; clip: 203 min; p < 0.01; non-rupt. A: coil: 164 min, clip: 200 min; p < 0.01). Coiling reduced the length of stay in the ICU (rupt. A: coil: 5.3 d; clip: 6d, p < 0.01; non-rupt. A: coil: 1.5d; clip: 2d; p = 0.21) and coiling significantly reduced the length of hospital stay (rupt. A: coil: 21.4d; clip: 26.8 d, p < 0.01; non-rupt. A: coil: 9.2d; clip: 17.5d; p = 0.01). The discharge to home ratio did not differ (rupt. A: clip: 31.6% coil: 29.7% nonrupt. A: clip: 74.5% coil: 80.5%). Conclusion: in a medium-volume neurovascular center, coiling significantly reduced the procedure time, the stay in the ICU, and the length of hospital stay suggesting favorable resource allocation in endovascular therapy. (orig.)

  11. Resolution of trigeminal neuralgia by coil embolization of a persistent primitive trigeminal artery aneurysm

    OpenAIRE

    Ladner, Travis R; Ehtesham, Moneeb; Davis, Brandon J; Khan, Imad S; Ghiassi, Mayshan; Ghiassi, Mahan; Singer, Robert J

    2013-01-01

    The persistent primitive trigeminal artery (PTA) is a rare anastomosis between the carotid artery and basilar artery. While most PTAs are asymptomatic, lateral variants can occasionally compress the trigeminal nerve and precipitate trigeminal neuralgia. Aneurysms of the PTA are exceptionally rare in the literature and have not previously been associated with trigeminal neuralgia. We present the first case of an aneurysm of the PTA causing trigeminal neuralgia. The patient underwent coil embol...

  12. Giant vertebral artery aneurysm in a child treated with endovascular parent artery occlusion and coil embolization

    OpenAIRE

    Hun-Soo Park; Ichiro Nakagawa; Takeshi Wada; Hiroyuki Nakagawa; Yasuo Hironaka; Kimihiko Kichikawa; Hiroyuki Nakase

    2014-01-01

    Background: Intracranial giant vertebral artery aneurysms are extremely rare in the pediatric population and are associated with significant morbidity and mortality. The present report describes a case of a pediatric patient with giant vertebral artery aneurysm who presented with intracranial mass effect. This patient was successfully treated with endovascular parent artery occlusion and coil embolization. Case Description: A 7-year-old girl presented with tetraparesis, ataxia, dysphagia,...

  13. Endovascular treatment of 20 acutely ruptured cerebral aneurysms with detachable coils

    International Nuclear Information System (INIS)

    To evaluate the preliminary results of endovascular coil treatment of acutely reptured aneurysms. Between August 1995 and December 1997, 18 patients with 20 ruptured aneurysms were treated. They were classified as Hunt and Hess grade I (n=3), grade II (n=1), grade III (n=3), grade IV (n=10) or grade V (n=1). Endovascular treatment was performed at mean 5.2 (range, 1-18) days. The first aneurysm was treated with mechanical detachable spirals (MDS) and the others with Guglielmi detachable coils (GDC). Aneurysm size was categorized as small (n=17) or large (n=3). Ten aneurysms were located in the anterior circulation, and ten in the posterior circulation. Using the Glasgow outcome scale (GOS), clinical outcome was evaluated 5 to 27 months after treatment in 11 patients. Three patients had already died. In 14 of the 18 patients (16 of 20 aneurysms : 80%), treatment was successful. Four aneurysms failed due to unsuccessful catheter placement (n=2), small aneurysm (n=1) or occlusion of the parent vessel (n=1). Total occlusion was observed in 13 aneurysms; 95-99%, or subtotal occlusion, in two, and less than 95%, or incomplete occlusion, in one. Technical complications included passing of wire (n=1) and unintentional parent artery occlusion (n=1). There was a 7.1%(1/14) morbidity rate, but no mortality related to the technique. Six patients with Hunt and Hess grade I-III had good clinical outcome (3 with GOS 1, and 2 with GOS 2). Four of the nine patients who were grade IV-V showed clinical improvement (GOS 3); two patients were clinically unchanged (GOS 4), and three died from the severity of primary hemorrhage. Endovascular coil treatement is a reasonable alternative for patients who are not candidates for conventional surgical treatment or in whom such treatment has failed

  14. Balloon-assisted coiling of intracranial aneurysms is not associated with a higher complication rate

    International Nuclear Information System (INIS)

    Within the neurosurgical literature on intracranial aneurysms, balloon-assisted coiling (BAC) remains controversial when compared to conventional coiling (CC). The aim of this study was to compare our results with BAC and CC over a 4-year period. Daily interventional neuroradiology has been available since March 2004 in our institution. Between March 2004 and February 2008, 275 patients with 357 aneurysms were treated by an endovascular approach, including 174 patients/204 aneurysms treated by CC (group I) and 80 patients/92 aneurysms treated by BAC (group II). The remaining patients were treated with other endovascular techniques. Indications of BAC were as follow: aneurysms with an unfavourable neck/sac ratio and/or a branch arising from the neck (90.2%), unstable coiling catheter (6.5%), and anticipated aneurysm rupture (3.3%). The clinical charts, procedural data, and angiographic results of groups I and II were compared. BAC was used in 25.8% (92/357) of all embolized aneurysms and it was successful in 83/92 aneurysms (90%). There was no significant difference in the procedure-related morbidity and mortality rates between group I (2.3% and 1.15%, respectively) and group II (2.5% and 1.25%, respectively). Although retreatment was more frequent in group II (13%) than in group I (11%), the difference was not statistically significant (P=0.8125). When BAC is used frequently, it is a safe and effective technique that is associated with complication rates comparable to those of CC. Although BAC is not associated with more stable anatomical results, it should be considered as an alternative therapeutic option for the treatment of broad-based intracranial aneurysms. (orig.)

  15. Combined use of cellulose acetate polymer and retrievable platinum coils for the thrombosis of cervical carotid aneurysms.

    OpenAIRE

    Hirotsune N; Kinugasa K; Mandai S; Tokunaga K; Handa A; Kawada S; Ohmoto T

    2000-01-01

    Cellulose acetate polymer (CAP) solution is a new liquid embolic material, and it has been used clinically for the thrombosis of cerebral aneurysms. The purpose of the study was to test a method of aneurysm treatment. In an experimental model, retrievable interlocking detachable coils (IDCs) were used to create an intraaneurysmal frame or prop and then CAP was injected into 20 experimentally induced canine cervical aneurysms. Intraaneurysmal thrombosis was induced 1 week after aneurysm creati...

  16. Procedure-related haemorrhage in embolisation of intracranial aneurysms with Guglielmi detachable coils

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, B.J.; Kim, K.H. [Department of Radiology, Seoul National University College of Medicine, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea); Han, M.H.; Chang, K.H. [Department of Radiology, Seoul National University College of Medicine, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea); Clinical Research Institute, Seoul National University Hospital, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea); Institute of Radiation Medicine, Seoul National University Medical Research Centre, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea); Seoul National University College of Medicine (Korea); Oh, C.W. [Department of Neurosurgery, Seoul National University College of Medicine, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea)

    2003-08-01

    We reviewed the haemorrhagic complications of the endovascular treatment of intracranial aneurysms, in terms of frequency, pre-embolisation clinical status, clinical and radiological manifestations, management and prognosis. In 275 patients treated for 303 aneurysms over 7 years we had seven (one man and six women - 2.3%) with haemorrhage during or immediately after endovascular treatment. All procedures were performed with a standardised protocol of heparinisation and anaesthesia. Four had ruptured aneurysms, two at the tip of the basilar artery, and one ach on the internal carotid and posterior cerebral artery, treated after 12, 5, 14, and 2 days, respectively, three were in Hunt and Hess grade 2 and one in grade 1. Bleeding occurred during coiling in three, after placement of at least four coils, and during manipulation of the guidewire to enter the aneurysm in the fourth. Haemorrhage was manifest as extravasation of contrast medium, with a sudden rise in systolic blood pressure in three patients. The other three patients had unruptured aneurysms; they had stable blood pressure and angiographic findings during the procedure, but one, under sedation, had seizures immediately after insertion of four coils, and the other two had seizures, headache and vomiting on the day following the procedure. Heparin reversal with protamine sulphate was started promptly started when bleeding was detected in four patients, and the embolisation was completed with additional coils in three. Emergency ventricular drainage was performed in the two patients with ruptured aneurysm and one with an unruptured aneurysm who had abnormal neurological responses or hydrocephalus. The bleeding caused a third nerve palsy in one patient, which might have been due to ischaemia and progressively improved. (orig.)

  17. Procedure-related haemorrhage in embolisation of intracranial aneurysms with Guglielmi detachable coils

    International Nuclear Information System (INIS)

    We reviewed the haemorrhagic complications of the endovascular treatment of intracranial aneurysms, in terms of frequency, pre-embolisation clinical status, clinical and radiological manifestations, management and prognosis. In 275 patients treated for 303 aneurysms over 7 years we had seven (one man and six women - 2.3%) with haemorrhage during or immediately after endovascular treatment. All procedures were performed with a standardised protocol of heparinisation and anaesthesia. Four had ruptured aneurysms, two at the tip of the basilar artery, and one ach on the internal carotid and posterior cerebral artery, treated after 12, 5, 14, and 2 days, respectively, three were in Hunt and Hess grade 2 and one in grade 1. Bleeding occurred during coiling in three, after placement of at least four coils, and during manipulation of the guidewire to enter the aneurysm in the fourth. Haemorrhage was manifest as extravasation of contrast medium, with a sudden rise in systolic blood pressure in three patients. The other three patients had unruptured aneurysms; they had stable blood pressure and angiographic findings during the procedure, but one, under sedation, had seizures immediately after insertion of four coils, and the other two had seizures, headache and vomiting on the day following the procedure. Heparin reversal with protamine sulphate was started promptly started when bleeding was detected in four patients, and the embolisation was completed with additional coils in three. Emergency ventricular drainage was performed in the two patients with ruptured aneurysm and one with an unruptured aneurysm who had abnormal neurological responses or hydrocephalus. The bleeding caused a third nerve palsy in one patient, which might have been due to ischaemia and progressively improved. (orig.)

  18. Unruptured aneurysms with cranial nerve symptoms: efficacy of endosaccular guglielmi detachable coil treatment

    International Nuclear Information System (INIS)

    To evaluate the efficacy of endosaccular Guglielmi detachable coil (GDC) treatment of unruptured aneurysms causing cranial nerve (CN) symptoms. Among a database of 218 patients whose aneurysms were treated using GDC, seven patients met the criteria for unruptured aneurysms presenting with symptoms and signs of CN palsy. Changes in CN symptoms before and after GDC treatment were reviewed. Aneurysms were located in the internal carotid-posterior communicating artery (n=3), the basilar bifurcation (n=1) and the cavernous internal carotid artery (n=3). CN symptoms included ptosis (n=6), mydriasis (n=2), and extraocular muscle (EOM) disorder (CN III: n=4; CN VI: n=3). Overall, improvement or resolution of CN symptoms after treatment was noted in five patients. CN symptoms in cases involving small (10 mm) and intradural aneurysms tended to respond better to GDC treatment. Ptosis was the initial symptom to show improvement, while EOM dysfunction responded least favourably. GDC coil packing appears to be an appropriate treatment method for the relief of CN symptoms associated with intracranial aneurysms

  19. Unruptured aneurysms with cranial nerve symptoms: efficacy of endosaccular guglielmi detachable coil treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Joon; Kim, Dong Ik; Lee, Seung Koo; Kim, Si Yeon [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2003-09-01

    To evaluate the efficacy of endosaccular Guglielmi detachable coil (GDC) treatment of unruptured aneurysms causing cranial nerve (CN) symptoms. Among a database of 218 patients whose aneurysms were treated using GDC, seven patients met the criteria for unruptured aneurysms presenting with symptoms and signs of CN palsy. Changes in CN symptoms before and after GDC treatment were reviewed. Aneurysms were located in the internal carotid-posterior communicating artery (n=3), the basilar bifurcation (n=1) and the cavernous internal carotid artery (n=3). CN symptoms included ptosis (n=6), mydriasis (n=2), and extraocular muscle (EOM) disorder (CN III: n=4; CN VI: n=3). Overall, improvement or resolution of CN symptoms after treatment was noted in five patients. CN symptoms in cases involving small (10 mm) and intradural aneurysms tended to respond better to GDC treatment. Ptosis was the initial symptom to show improvement, while EOM dysfunction responded least favourably. GDC coil packing appears to be an appropriate treatment method for the relief of CN symptoms associated with intracranial aneurysms.

  20. The Use of Solitaire AB Stents in Coil Embolization of Wide-Necked Cerebral Aneurysms.

    Directory of Open Access Journals (Sweden)

    Teng-Fei Li

    Full Text Available The Solitaire AB stent is one of many assistant stents used for treating wide-necked cerebral aneurysm, and has been used since 2003. However, large sample studies on its safety and effectiveness are lacking. The objective of this study was to evaluate the effectiveness and safety of the Solitaire AB stent in the coil embolization of wide-necked cerebral aneurysms.Retrospective review of the clinical and image data of 116 patients with wide-necked cerebral aneurysms who had been enrolled at six interventional neuroradiology centers from February 2010 to February 2014 and had been treated by coil embolization; in total, 120 Solitaire AB stents were used. The degree of aneurysm occlusion was examined using digital subtraction angiography (DSA immediately after the procedure and during follow-up, and was graded using the modified Raymond classification. We also observed complications to evaluate the safety and effectiveness of this therapy.The 120 Solitaire AB stents (4 mm × 15 mm, four stents; 4 mm × 20 mm, 16 stents; 6 mm × 20 mm, 36 stents; 6 mm × 30 mm, 64 stents were inserted to treat 120 wide-necked cerebral aneurysms. All stents were inserted successfully. DSA immediately post-surgery revealed 55 cases of complete occlusion, 59 cases of neck remnant, and six cases of aneurysm remnant. Perioperatively, there were four cases of hemorrhage and four cases of stent thrombosis. The follow-up spanned 3-37 months; of 92 patients examined by DSA at the 6-month follow up, 12 had disease recurrence.The Solitaire AB stent is effective with a good technical success rate and short-term effect for assisting coil embolization of wide-necked cerebral aneurysms.

  1. Surveillance of intracranial aneurysms treated with detachable coils: a comparison of MRA techniques

    International Nuclear Information System (INIS)

    Two MRA techniques were evaluated for the follow-up of coiled intracranial aneurysms. Twenty-nine coiled aneurysms were evaluated for a total of 36 follow-up assessments using 3D time-of flight MRA (TOF MRA), an auto-triggered elliptic-centric-ordered three-dimensional gadolinium-enhanced MR angiogram (ATECO MRA), as well as a selective digital subtraction angiography (DSA), which served as the ''gold standard''. Confident visualization was seen in 36 (100%) of ATECO MRAs and in 32 (89%) of the TOF MRAs. Eleven residual aneurysm components (RACs) greater than 2 mm were described on DSA. Of these, nine were seen on ATECO MRA (sensitivity of 81% and specificity of 88%) and four were seen on TOF MRA (sensitivity of 40% and specificity of 90%). The two RACs not seen on ATECO MRA both measured 3 mm. The six RACs not seen on TOF MRA measured 3, 4 and 5 mm. ATECO MRA provides a non-invasive reliable angiogram for the surveillance of coiled aneurysms and is superior to TOF MRA for this purpose. (orig.)

  2. Intra-arterial tirofiban infusion for thromboembolic complication during coil embolization of ruptured intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Dae, E-mail: aronnn@naver.com [Department of Radiology, Seoul National University Boramae Medical Center, Seoul National University College of Medicine, 425 Sindaebang-dong, Dongjak-gu, Seoul 156-707 (Korea, Republic of); Lee, Jong Young, E-mail: gen78@naver.com [Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, 28 Yongon-dong, Jongno-gu, Seoul 110-744 (Korea, Republic of); Seo, Jung Hwa, E-mail: jhseo34@gmail.com [Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, 28 Yongon-dong, Jongno-gu, Seoul 110-744 (Korea, Republic of); Kang, Hyun-Seung, E-mail: hsk4428@yahoo.com [Department of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, 28 Yongon-dong, Jongno-gu, Seoul 110-744 (Korea, Republic of); Kim, Jeong Eun, E-mail: eunkim@snu.ac.kr [Department of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, 28 Yongon-dong, Jongno-gu, Seoul 110-744 (Korea, Republic of); Jung, Keun Hwa, E-mail: jungkh@gmail.com [Department of Neurology, Seoul National University Hospital, Seoul National University College of Medicine, 28 Yongon-dong, Jongno-gu, Seoul 110-744 (Korea, Republic of); Han, Moon Hee, E-mail: hanmh@snuh.org [Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, 28 Yongon-dong, Jongno-gu, Seoul 110-744 (Korea, Republic of); Department of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, 28 Yongon-dong, Jongno-gu, Seoul 110-744 (Korea, Republic of)

    2012-10-15

    Introduction: Intra-arterial (IA) thrombolytic intervention for acute thrombosis has been challenged due to the risk of bleeding during the endovascular treatment of ruptured aneurysms. We present the results of IA tirofiban infusion for thromboembolic complications during coil embolization in patients with ruptured intracranial aneurysms. Methods: Thromboembolic events requiring thrombolytic intervention occurred in 39 (10.5%) cases during coil embolization of 372 consecutive ruptured intracranial aneurysms. Maximal aneurysm diameters of 39 patients (mean age, 54.7 ± 13.2 years; 23 female, 16 male) ranged from 2.1 to 13.1 mm (mean, 6.6 ± 3.0 mm). The anterior communicating artery was the most common site (n = 13), followed by the middle cerebral artery (n = 9) and the posterior communicating artery (n = 7). In this series, we used intracranial stents in 10 patients during the procedure. Superselective IA tirofiban infusion through a microcatheter was performed to resolve thrombi and emboli. We assessed the efficacy and safety of IA tirofiban infusion in patients with ruptured aneurysms. Results: Intraarterially administered tirofiban doses ranged from 0.25 to 1.25 mg (mean, 0.71 ± 0.26 mg). Effective thrombolysis or recanalization was achieved in 34 patients (87.2%), and three patients (7.7%) suffered distal migration of clots with partial recanalization. The rest (5.1%) had no recanalization. Nonconsequent intracerebral hemorrhage occurred in two patients (5.1%) after the procedure. Thromboemboli-related cerebral infarction developed in eight patients, and only two patients remained infarction related disabilities. Conclusion: IA tirofiban infusion seems to be efficacious and safe for thrombolysis during coil embolization in patients with ruptured intracranial aneurysms.

  3. Intra-arterial tirofiban infusion for thromboembolic complication during coil embolization of ruptured intracranial aneurysms

    International Nuclear Information System (INIS)

    Introduction: Intra-arterial (IA) thrombolytic intervention for acute thrombosis has been challenged due to the risk of bleeding during the endovascular treatment of ruptured aneurysms. We present the results of IA tirofiban infusion for thromboembolic complications during coil embolization in patients with ruptured intracranial aneurysms. Methods: Thromboembolic events requiring thrombolytic intervention occurred in 39 (10.5%) cases during coil embolization of 372 consecutive ruptured intracranial aneurysms. Maximal aneurysm diameters of 39 patients (mean age, 54.7 ± 13.2 years; 23 female, 16 male) ranged from 2.1 to 13.1 mm (mean, 6.6 ± 3.0 mm). The anterior communicating artery was the most common site (n = 13), followed by the middle cerebral artery (n = 9) and the posterior communicating artery (n = 7). In this series, we used intracranial stents in 10 patients during the procedure. Superselective IA tirofiban infusion through a microcatheter was performed to resolve thrombi and emboli. We assessed the efficacy and safety of IA tirofiban infusion in patients with ruptured aneurysms. Results: Intraarterially administered tirofiban doses ranged from 0.25 to 1.25 mg (mean, 0.71 ± 0.26 mg). Effective thrombolysis or recanalization was achieved in 34 patients (87.2%), and three patients (7.7%) suffered distal migration of clots with partial recanalization. The rest (5.1%) had no recanalization. Nonconsequent intracerebral hemorrhage occurred in two patients (5.1%) after the procedure. Thromboemboli-related cerebral infarction developed in eight patients, and only two patients remained infarction related disabilities. Conclusion: IA tirofiban infusion seems to be efficacious and safe for thrombolysis during coil embolization in patients with ruptured intracranial aneurysms

  4. Coil embolization using the self-expandable closed-cell stent for intracranial saccular aneurysm: A single-center experience of 289 consecutive aneurysms

    International Nuclear Information System (INIS)

    Aim: To present the clinical and radiological follow-up results of coil embolization using the Enterprise stent for intracranial saccular aneurysms. Materials and methods: The clinical and morphological outcomes of 261 consecutive patients with a total of 289 aneurysms that were treated with a stent-protected coiling technique using the Enterprise stent from June 2008 to August 2011 were assessed. Results: Stents were delivered before first coil insertion in 162 aneurysms (56.1%), during coiling in 68 (23.5%), and after completion of coil insertion in 59 (20.4%). Procedure-related complications occurred in 36 patients (13.8%), and four (1.5%) suffered permanent neurological sequelae. Successful occlusion after coil embolization was achieved in 205 aneurysms (70.9%) and subtotal occlusion was achieved in 84. During the mean follow-up of 12.4 (±5.8) months, follow-up imaging of 229 aneurysms (79.2%) documented stable occlusion in 183 (79.9%) of the lesions, minor recanalization in 17 (7.4%), and major recanalization in 29 (12.7%). Follow-up angiography of 110 aneurysms (38.1%) demonstrated in-stent stenosis in 14 (12.7%) and stent migration in five (4.5%). Eleven patients (4.2%) suffered late delayed infarction during the follow-up period, which was related to cessation or modification of anti-platelet medication. Conclusion: The stent-protection technique using the Enterprise stent is useful and effective for coil embolization of wide-necked aneurysms due to easy navigation and precise placement. However, the possibility of procedure-related complications, in-stent stenosis, and delayed cerebral infarction should be noted

  5. Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling

    OpenAIRE

    Westerlaan, H. E.; Gravendeel, J.; Fiore, D; Metzemaekers, J. D. M.; Groen, R. J. M.; Mooij, J.J.A.; Oudkerk, M.

    2007-01-01

    Introduction We sought to establish whether CT angiography (CTA) can be applied to the planning and performance of clipping or coiling in ruptured intracranial aneurysms without recourse to intraarterial digital subtraction angiography (IA-DSA). Methods Over the period April 2003 to January 2006 in all patients presenting with a subarachnoid haemorrhage CTA was performed primarily. If CTA demonstrated an aneurysm, coiling or clipping was undertaken. IA-DSA was limited to patients with negativ...

  6. Nursing assistance for spring coil occlusion for the treatment of intracranial giant internal carotid artery aneurysms

    International Nuclear Information System (INIS)

    Objective: To discuss the importance of balloon occlusion test before interventional treatment of the intracranial giant internal carotid artery aneurysms and to sum up the nursing experience in assisting the procedure. Methods: Proper perioperative nursing measures were carried out for 12 patients, who suffered from intracranial giant internal carotid artery aneurysm and underwent spring coil occlusion treatment. Nursing measures included mental care, observation of the vital signs, prevention of the complications, etc. Results: Neither death nor exacerbation of the condition occurred in all the 12 patients. The patients were discharged from the hospital with a mean hospitalization of nine days. During a follow-up period ranged from 4 months to one year, seven patients had no disagreeable feeling, one patient complained of discomfort but no abnormality was found on follow-up DSA, and disappearance of the aneurysm was observed in 4 patients. Conclusion: The monitoring of the vital signs, the prevention of the complications and the standard nursing care are the key points for ensuring a successful operation in treating intracranial giant internal carotid artery aneurysms with spring coil occlusion. (authors)

  7. Treatment results of endosaccular coil embolization of asymptomatic unruptured intracranial aneurysms in elderly patients

    OpenAIRE

    Oishi, Hidenori; Yamamoto, Munetaka; Nonaka, Senshu; Shimizu, Takashi; Yoshida, Kensaku; Mitsuhashi, Takashi; Arai, Hajime

    2014-01-01

    Background and purpose We report the results of endosaccular coil embolization of asymptomatic unruptured intracranial aneurysms (UIAs) in elderly patients (≥65 years). Materials There were 375 elderly patients with 400 asymptomatic UIAs. Patients were divided into two groups: group A included patients aged 65–74 years and group B patients aged ≥75 years. Results Endovascular procedures were completed in 97.8% of patients. Immediate anatomical outcomes showed complete occlusion in 53.7%, resi...

  8. Prediction of shape diameter undergoing coil embolization of saccular intracranial aneurysm treatment using a hybrid decision support system

    International Nuclear Information System (INIS)

    The purpose of the study was to design a hybrid decision support system (HDSS) that could simulate the embolized coil selection pattern of the radiologists in aneurysms treatment. As the longest available length of the coils should be used in most cases, therefore only the shape diameter (SD) selection was modeled and varied. Ninety-eight aneurysms successfully treated by a radiologist with coil embolization were divided into two groups (86 for training and 12 randomly selected for validating). Eight aneurysms treated by another radiologist were also used to cross validate the proposed HDSS. The HDSS was developed using the classification and the linear regression methods (LRM). The dome and the width of an aneurysm were used as the system inputs. The system outputs were the SDs of the first three coils indexed according to the insertion order. The HDSS that consisted of Bagging classification and LRM achieved the highest accuracy for all cases. The errors were within 1 mm for the SD selection of the first two coils. For the third coil, the SD selection within 1 mm bound had 80 % accuracy. The experimental results indicated the feasibility of using the HDSS as the guidance for selecting the SDs of the first two coils. The selection of the third coil required more training data for the rarely used SD. Moreover, the cross validation with another radiologist showed the feasibility of using the proposed HDSS as the guidance, however further validation with more data is recommended.

  9. Feasibility and safety of endovascular stent and Guglielmi detachable coils for treating acute ruptured wide-necked intracranial aneurysms

    International Nuclear Information System (INIS)

    Objective: To discuss the feasibility and safety of treatment on acute ruptured wide-necked intracranial aneurysms with endovascular stent and Guglielmi detachable coils (GDS). Methods: The coronary stents were first implanted across the neck of 57 acute ruptured wide-necked intracranial aneurysms with microcatheters introducing into the aneurysm sac through the stent mesh. GDCs were used to embolize the aneurysms. Results: 56 procedures were successful with only one failure of stent implantation due to tortuous vessel. Over 90% occlusion were achieved in 56 embolized aneurysms. The patients recovered well with patency of the parent arteries. Conclusion: Endovascular therapy with stent implantation and GDC placement is a safe and feasible approach for the treatment of acute ruptured wide-necked intracranial aneurysms. (authors)

  10. Combined use of cellulose acetate polymer and retrievable platinum coils for the thrombosis of cervical carotid aneurysms.

    Directory of Open Access Journals (Sweden)

    Hirotsune N

    2000-08-01

    Full Text Available Cellulose acetate polymer (CAP solution is a new liquid embolic material, and it has been used clinically for the thrombosis of cerebral aneurysms. The purpose of the study was to test a method of aneurysm treatment. In an experimental model, retrievable interlocking detachable coils (IDCs were used to create an intraaneurysmal frame or prop and then CAP was injected into 20 experimentally induced canine cervical aneurysms. Intraaneurysmal thrombosis was induced 1 week after aneurysm creation. Complete thrombosis was attempted in 12 aneurysms, and partial thrombosis was attempted in 4. Four other aneurysms served as controls. Follow-up angiography was performed for up to 8 weeks, and with the exception of 4 aneurysms, which were kept for a 2-year long-term follow-up study, the aneurysms were then harvested for histological examination. Thrombosis was successfully achieved in all cases except for 2 enlarged aneurysms that were initially partially thrombosed. No thromboembolism to distal vessels was observed. No compaction or shift of the CAP-IDC complex occurred even after 2 years. Histologically, CAP and IDCs conformed to the massive thrombotic complex without any fragmentation. By creating a frame or prop with retrievable microcoils, we were able to inject the CAP implies a comparison safely and precisely than has been previously reported. Our findings suggest that this method will be useful for the treatment of cerebral aneurysms.

  11. Double-balloon remodeling for coil embolization of a primitive trigeminal artery variant aneurysm. A case report.

    Science.gov (United States)

    Takigawa, Tomoji; Suzuki, Kensuke; Sugiura, Yoshiki; Suzuki, Ryotaro; Takano, Issei; Shimizu, Nobuyuki; Tanaka, Yoshihiro; Hyodo, Akio

    2014-01-01

    Here we describe the case of a patient with a wide-necked unruptured aneurysm arising at origin of a persistent primitive trigeminal artery (PTA) variant from the right internal carotid artery (ICA), supplying the territory of the right superior cerebellar artery and the anterior inferior cerebellar artery. To preserve the ICA and the PTA variant, coil embolization of the aneurysm was performed using a double-balloon remodeling technique (HyperForm™ and HyperGlide™ Occlusion Balloon Systems; ev3 Endovascular Inc., Irvine, CA, USA). The association of a PTA variant with an aneurysm is very rare. To our knowledge, this is the first description of the use of coil embolization using double-balloon remodeling to treat a PTA variant aneurysm. This technique permits complete embolization and reduces the risk of cerebral and cerebellar ischemia. PMID:24976091

  12. Successful Coil Embolization of a Ruptured Basilar Artery Aneurysm in a Child with Leukemia: A Case Report

    OpenAIRE

    HAYASHI, Shihori; Maehara, Taketoshi; Mukawa, Maki; Aoyagi, Masaru; YOSHINO, Yoshikazu; NEMOTO, Shigeru; Ono, Toshiaki; Ohno, Kikuo

    2013-01-01

    Ruptured intracranial aneurysms are rare in the pediatric population compared to adults. This has incited considerable discussion on how to treat children with this condition. Here, we report a child with a ruptured saccular basilar artery aneurysm that was successfully treated with coil embolization. A 12-year-old boy with acute lymphoblastic leukemia and accompanying abdominal candidiasis after chemotherapy suddenly complained of a severe headache and suffered consciousness disturbance mome...

  13. Balloon-assisted coil embolization of a posterior cerebral artery aneurysm via a persistent primitive trigeminal artery: technical note

    Energy Technology Data Exchange (ETDEWEB)

    Schlamann, Marc; Doerfler, Arnd; Forsting, Michael; Wanke, Isabel [University of Essen Medical School, Department of Neuroradiology, Institute of Diagnostic and Interventional Radiology, Essen (Germany); Schoch, Beate [University of Essen Medical School, Department of Neurosurgery, Essen (Germany)

    2006-12-15

    We present a patient with an acutely ruptured, wide-necked aneurysm of the left posterior cerebral artery (PCA) treated with Guglielmi detachable coils using the remodeling technique. Since the left vertebral artery was compressed due to a tumor in the cerebellopontine angle and the right vertebral artery was hypoplastic, we used a carotid artery approach via a persistent primitive trigeminal artery (PPTA) to selectively catheterize the aneurysm. The aneurysm was occluded completely. To our knowledge this is the first case of a wide-necked PCA aneurysm treated via a PPTA and using the remodeling technique. In patients with hypoplastic vertebral arteries and a PPTA, this approach may represent an alternative for selective embolization of posterior circulation aneurysms not amenable to the conventional approach. (orig.)

  14. Hepatic arterial loop with accessory right hepatic artery aneurysm with celiac atresia: endovascular therapy with a stent and detachable coils.

    Science.gov (United States)

    Ferro, Carlo; Rossi, Umberto G; Seitun, Sara; Bovio, Giulio; Castellan, Lucio; De Paolis, Marco; Castaneda-Zuniga, Wilfrido R

    2008-08-01

    The present report describes an unusual case of an aneurysm of a right hepatic artery (RHA) branching from the superior mesenteric artery; the accessory RHA was looped to the left hepatic artery arising from the celiac axis (CA) and was associated with congenital atresia of the CA. The accessory RHA aneurysm was treated with the placement of a bare stent and detachable coils through the mesh of the stent. Complete and prompt exclusion of the aneurysm was achieved with blood flow preservation in the parent artery at midterm follow-up. PMID:18656020

  15. [Stent-Assisted Coil Embolization of a Dissecting Aneurysm of the Posterior Cerebral Artery: A Case Report].

    Science.gov (United States)

    Haruma, Jun; Sugiu, Kenji; Yukiue, Tadato; Sasaki, Tatsuya; Hattori, Yasuhiko; Kobayashi, Kazuki; Yoshida, Hideyuki; Muneda, Koji; Date, Isao

    2015-12-01

    Dissecting aneurysms of the posterior cerebral artery (PCA) are rare, especially those at the P1 segment. Here, we describe the case of a 57-year-old woman with a subarachnoid hemorrhage (SAH). Computed tomography angiography (CTA) and digital subtraction angiography (DSA) revealed a small (3 mm) dissecting aneurysm with the typical pearl-and-string sign at the right P1 segment. Fourteen days after onset, the patient developed aphasia. DSA revealed vasospasm of the right middle cerebral artery, and we performed endovascular treatment by the intra-arterial injection of 1-(5-isoquinolinesulfonyl) homopiperazine. After this treatment, the patient's symptoms recovered immediately. Vertebral angiography revealed enlargement of the dissecting aneurysm (up to 7 mm diameter). We started a loading dose of 300 mg aspirin and 400 mg clopidogrel after observing growth of the aneurysm. Fifteen days after onset, we performed a stent-assisted coil embolization, and obtained nearly complete obliteration of the aneurysm with preserved patency of the parent artery. Six-month follow-up DSA demonstrated complete occlusion of the aneurysm with good patency of the stented PCA; the patient was at modified Rankin Scale 1. In the treatment of ruptured dissecting aneurysms, parent vessel occlusion (PVO) with aneurysm is common. However, PVO may cause both cerebral infarction of the distal area and perforator occlusion of the occluded vessel. Stent-assisted coil embolization can preserve parent vessel flow and obliterate the aneurysm. Stents offer a therapeutic alternative for PCA dissecting aneurysms, especially when PVO cannot be tolerated. PMID:26646176

  16. Large Residual Volume, Not Low Packing Density, Is the Most Influential Risk Factor for Recanalization after Coil Embolization of Cerebral Aneurysms

    OpenAIRE

    SADATO, Akiyo; Hayakawa, Motoharu; Adachi, Kazuhide; Nakahara, Ichiro; Hirose, Yuichi

    2016-01-01

    Background Tight coil packing with density of at least 20%–25% is known to be important for preventing recanalization after embolization of cerebral aneurysms. However, large aneurysms sometimes recanalize regardless of the packing density, suggesting that the absolute residual volume which is determined by aneurysm volume and packing density may be more important risk factor for recanalization. To validate this hypothesis, we analyzed the factors affecting the outcomes of treated aneurysms a...

  17. Flow diversion and coil embolization may perform best in conjunction for treatment of intracranial aneurysms: a hemodynamic investigation

    Science.gov (United States)

    Damiano, Robert; Ma, Ding; Siddiqui, Adnan; Meng, Hui

    2015-11-01

    Coiling and flow diversion is the current standard for treatment of intracranial aneurysms (IAs). Coils deployed into the IA sac trigger its thrombotic occlusion, while flow diverters (FDs) deployed across the IA ostium redirect blood flow and reconstruct the parent vessel. Despite the wide adoption of these interventions, poor treatment outcomes have been reported. Recent clinical reports indicate that IA patients treated with both coils and FDs had better outcomes, compared to individual strategies alone. To better understand the hemodynamic mechanisms underlying coiling and flow diversion, we applied our advanced FEM-based device modeling toolset in conjunction with CFD to investigate 3 clinical strategies: coiling, FD, and FD with adjunctive coiling. Using 3 patient-specific IAs as test beds, we assessed the hemodynamic modifications induced by each strategy. Hemodynamic modifications in inflow rate, velocity, and wall shear stress revealed that coils were most effective at reducing intra-aneurysmal flow, while FD worked best at reducing flow into the IA sac. When coils were combined with FD, these effects appeared to be synergistically enhanced. Our modeling results support clinical observations that flow diversion and coiling may work best in conjunction for treating IAs. Funded by the National Institutes of Health (1R01 NS 091075-01).

  18. Combined Neuroform Intracranial Stent and Bioactive Matrix Detachable Coil for Embolization of a Broad-Necked Persistent Primitive Trigeminal Artery Aneurysm

    Science.gov (United States)

    Zhao, Q.P.; Li, T.L.; Duan, C.Z.; Chen, G.Z.

    2005-01-01

    Summary We report a patient with a wide-necked aneurysm arising at the bifurcation of the right internal carotid artery and the persistent primitive trigeminal artery (PPTA) treated successfully by Matrix detachable coil occlusion and assisted by a Neuroform intracranial stent. First, a Neuroform self-expanding intracranial stent was delivered via a 5-F Guider Softtip XP and placed as desired, then the aneurysm dome was embolized with two Matrix detachable coils through the interstices of the stent. The aneurysm was 80% occluded angiographically and the parent artery was patent. DSA imaging six months after the procedure showed the aneurysm to be obliterated at angiography and the neck tissue thickness of the aneurysm to be increased, but the parent artery diameter was not impacted. We describe the case in detail and discuss our preliminary experience of using the Neuroform stent and Matrix detachable coils for the treatment of a PPTA wide-necked aneurysm. PMID:20584437

  19. Comparison of endovascular coiling and surgical clipping for the treatment of intracranial aneurysms: A prospective study.

    Directory of Open Access Journals (Sweden)

    Zeinab Taheri

    2015-03-01

    Full Text Available Management of intracranial aneurysms has made debates about the best treatment modality in recent years. The aim of this study was to compare the interventional outcomes between two groups of patients, one treated with endovascular coiling and the other treated with surgical clipping.This prospective study included 48 patients with intracranial aneurysms who underwent endovascular coiling (27 patients or surgical clipping (21 patients from July 2011 to August 2013. A neurologist examined patients in admission and followed them by phone call 1-year after intervention.Mean modified Rankin Scale (MRS score at the time of admission in endovascular group was 2.86 ± 0.974 whereas it was 3.81 ± 1.078 in surgical clipping group (P = 0.0040. Focal neurologic signs were higher in clipping during procedures (P = 0.0310. Of 37 patients who followed up for a year, 19 were in endovascular group and 18 in surgical clipping group. At 1 year follow-up, MRS improvement was statistically significant in coiling group (P = 0.0090, but not in clipping group (P = 0.8750. Mean difference of MRS score at the time of admission and at one year later, was 0.947 ± 1.224 in endovascular group and 0.111 ± 2.083 in surgical group (P = 0.3000.There was no statistically significant difference at 1 year outcome between two groups. We recommend further interventional studies with larger sample sizes for better evaluation of the modalities.

  20. Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling

    NARCIS (Netherlands)

    Westerlaan, H. E.; Gravendeel, J.; Fiore, D.; Metzemaekers, J. D. M.; Groen, R. J. M.; Mooij, J. J. A.; Oudkerk, M.

    2007-01-01

    Introduction We sought to establish whether CT angiography (CTA) can be applied to the planning and performance of clipping or coiling in ruptured intracranial aneurysms without recourse to intraarterial digital subtraction angiography (IA-DSA). Methods Over the period April 2003 to January 2006 in

  1. [Elective cerebral arteriovenous malformation treatment with onyx after coil embolization of ruptured, flow-realeted aneurysm of the posterior circulation].

    Science.gov (United States)

    Poncyljusz, Wojciech; Falkowski, Aleksander; Rać, Monika; Sagan, Leszek; Kojder, Ireneusz

    2012-01-01

    Intracranial arteriovenous posterior circulation malformation was planned to embolize by onyx injection after acute coil embolization of ruptured flow-realeted aneurysm of posterior cerebral artery. Control angiography revealed completely embolized malformation with normal vessel patency at the end of procedure. There were no adverse events related to this procedure and no neurologic deficit at the discharge. PMID:23276020

  2. A novel approach using Neuron 6F guiding catheter for the embolization of intracranial aneurysm with coiling of the parent internal carotid artery.

    Science.gov (United States)

    Wang, Donghai; Wang, Ying; Su, Wandong; Wang, Yunyan; Li, Gang; Li, Xingang

    2015-01-01

    To describe our initial experience and early outcomes with distal placement of the Neuron 6F guiding catheter through coiled ICA for aneurysmal EVT. We examined the utility of the Neuronf 70 6F guiding catheter for the embolization procedure in such cases, fourteen cases of aneurysm with coiling of the parent ICA are presented via traditional guiding catheters. With the support of 8F ENVOY guiding catheter as a shuttle sheath, the Neuron(TM) 70 6F guiding catheter was successfully placed through coiled extracranial ICA, so the mirocatheter could be delivered to a more strategic position for embolization of the aneurysm. Coiling of extracranial ICA was found as parent artery on angiogram in all patients with ruptured aneurysms. Even where there were two curvatures of more than 360° in the coiled segment of the ICA, Neuron(TM) 70 6F guiding catheter could be placed through the coiling to a distal position and enabled EVT of intracranial aneurysms with no related neurological complications. Neuron guiding catheter is a useful device for embolization of aneurysm where there is coiling of parent ICA, easily placed through the coiling of the ICA and provided robust anatomical support via enhanced catheter-to-vessel wall engagement. PMID:25785169

  3. Differential Gene Expression in Well-healed and Poorly Healed Experimental Aneurysms after Coil Treatment1

    OpenAIRE

    Kadirvel, Ramanathan; Ding, Yong-Hong; Dai, Daying; Lewis, Debra A.; Kallmes, David F

    2010-01-01

    Increased gene expression in densely packed aneurysms was associated with adhesion molecules, proteases, and cytokines in the rabbit aneurysm model; loosely packed aneurysms showed increased expression of multiple structural molecules, including collagens.

  4. A Retrospective Study of Survivors of Endovascular Coiling for Posterior and Anterior Aneurysms: Medical and Patient Perspectives.

    Science.gov (United States)

    Wilson, Sarah J; Drackford, Ruth; Holt, Michael

    2015-08-01

    This article documents the longer-term medical and psychosocial outcomes of patients referred for endovascular coiling.There is limited research investigating outcome following endovascular coiling for posterior compared to anterior circulation aneurysms, and minimal understanding of how medical outcomes relate to patient experiences of treatment and quality of life.We studied a consecutive cohort of 80 patients referred Australia wide for endovascular coiling between 1995 and 2003 (49% posterior; 76% ruptured; 69% women, mean age 51.5 years). We used a mixed methods approach, assessing medical outcome with the Modified Rankin Scale (MRS) in 61 patients (76%), and health-related quality of life and psychosocial functioning using the EuroQol questionnaire and a qualitative semistructured interview in 49 patients (61%).Despite the high proportion of posterior aneurysms, the majority of patients (80%) showed good medical outcomes as indicated by regained independence of activities of daily living (MRS score ≤3). Patients with unruptured aneurysms were significantly more likely to show good outcomes (P < 0.04), whereas aneurysm location (posterior, anterior, or mixed) showed no significant effect. In patients with good medical outcomes, greater functional disability was associated with neurological complications surrounding treatment (P < 0.05). Good outcomes correlated with higher EuroQol ratings (P < 0.001) and the experience of less change after treatment (P < 0.001), although psychosocial adjustment issues were reported by most of the patients, including those with no medical symptoms.These results support the long-term efficacy of endovascular coiling, particularly for posterior circulation aneurysms. They have implications for guiding clinicians and patients in their choice of treatment, as well as the provision of psychological counseling for patient adjustment issues posttreatment. PMID:26266373

  5. Angle change of the parent arteries after stent-assisted coil embolization of wide-necked intracranial bifurcation aneurysms

    International Nuclear Information System (INIS)

    Aim: To investigate the angle changes of the parent arteries after stent-assisted coil embolization of wide-necked intracranial bifurcation aneurysms. Materials and methods: The adjacent parent arterial angles before and after stent-assisted coil embolization were measured in 38 patients with aneurysms of the anterior communicating artery (ACoAA) and 41 patients with bifurcation aneurysms of the middle cerebral artery (MCABA). Variables were analysed in relation to the angle changes. Results: Vascular angles of the parent arteries significantly increased by 27.8° (±18.5°) immediately after stent-assisted coil embolization in 79 cases (p < 0.001), with 25.7° (±14.8°) in ACoAA and 29.7° (±21.4°) in MCABA, respectively. In 51 (64.6%) cases with follow-up angiography (mean interval 13.5 ± 4.1 months), vascular angles increased by 27.2° (±17.1°) immediately after treatment and further increased by 20.7° (±14.3°) at the last follow-up (all p < 0.001). More acute pre-stent angles of the parent arteries correlated with greater post-stent angle changes (p = 0.006). Younger age tended to be inversely related to post-stent angle changes (p = 0.091). Conclusion: Stent placement during coil embolization induced significant changes in the aneurysm–parent artery relationship. Further study is needed to elicit the association between angle change of the parent arteries and aneurysmal stability after coil embolization

  6. Microembolic signal monitoring and the prediction of thromboembolic events following coil embolization of unruptured intracranial aneurysms: diffusion-weighted imaging correlation

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jae-Hoon; Park, Jaechan [Kyungpook National University Hospital, Department of Neurosurgery, Daegu (Korea, Republic of); Kang, Dong-Hun [Kyungpook National University Hospital, Department of Neurosurgery, Daegu (Korea, Republic of); Kyungpook National University Hospital, Department of Radiology, Daegu (Korea, Republic of); Kim, Yong-Won [Kyungpook National University Hospital, Department of Neurology, Daegu (Korea, Republic of); Kyungpook National University Hospital, Department of Radiology, Daegu (Korea, Republic of); Kim, Yong-Sun [Kyungpook National University Hospital, Department of Radiology, Daegu (Korea, Republic of)

    2014-10-12

    Microembolic signal (MES) monitoring with transcranial Doppler ultrasonography (TCD) may allow for early prediction of thromboembolisms following endovascular coiling of unruptured intracranial aneurysms (UIAs). However, the method has not gained widespread use and may benefit from correlation with diffusion-weighted imaging (DWI) of acute ischemic lesions after coiling. This purposed to evaluate the relationship between MESs and DWI-positive lesions more precisely. We conducted a prospective study on 45 consecutive patients. TCD was performed over the artery that is dependent on the site of aneurysm, but seven patients (15.6 %) could not be examined due to the lack of an adequate cranial window. Consequently, 38 patients were available to detect MESs immediately (MES-1) and 24 h (MES-2) after coiling for UIAs. We also checked DWI 1 day after the coiling and analyzed correlations between the TCD and DWI findings. MES-1 and MES-2 were positive in 25 (65.7 %) and 14 (36.8 %) patients, respectively. DWI-positive lesions were seen in 20 (52.6 %) patients, and only 1 (2.6 %) patient was symptomatic. MES-1 and MES-2 were strongly correlated with the number of DWI-positive lesions (Spearman's correlation coefficient = 0.79 and 0.70, P < 0.01 and P < 0.01, respectively). Additionally, there was a significant correlation between MES-1 and MES-2 (Spearman's correlation coefficient = 0.70). Based upon the significant correlation between MES and DWI findings, MES may have a role for early detection of ischemic complications after coiling of UIAs. In addition, future study for further validation with clinical application seems requiring. (orig.)

  7. The role of inflammation in cerebral aneurysms

    Directory of Open Access Journals (Sweden)

    Ali H Turkmani

    2015-06-01

    Full Text Available The natural history of unruptured intracranial aneurysms (IAs is poorly understood. At present, risk factors for aneurysm rupture are limited to demographics and rudimentary anatomic features of the aneurysm. The first sign of aneurysm destabilization and rupture may be subarachnoid hemorrhage, a potentially devastating brain injury with high morbidity and mortality. An emerging body of literature suggests a complex inflammatory cascade likely promotes aneurysm wall remodeling and progressive ballooning of the arterial wall, ultimately terminating in aneurysm rupture. These events likely begin with hemodynamic, flow-related endothelial injury; the injured endothelium stimulates inflammation, including the recruitment and transmigration of inflammatory cells, particularly macrophages. Various proteases are secreted by the inflammatory infiltrate, resulting in degradation of the extracellular matrix and the structural changes unique to IAs. Detailed understanding of these inflammatory processes may result in (1 early identification of patients at high risk for aneurysm rupture, perhaps via arterial wall imaging, and (2 targeted, noninvasive therapies to treat or even prevent cerebral aneurysms.

  8. Follow-up of intracranial aneurysms treated with detachable coils: comparison of plain radiographs, 3D time-of-flight MRA and digital subtraction angiography

    International Nuclear Information System (INIS)

    All patients with aneurysms treated with Guglielmi detachable coils (GDC) are undergo angiography to assess long-term stability of aneurysm exclusion or to show recurrence of the aneurysm sac, which may require further treatment. We prospectively compared the plain-film appearance of the coil-mass, 3D time-of-flight MR angiography (TOF MRA) and digital subtraction angiography (DSA) for the detection of aneurysm recanalisation during follow-up. We studied 60 patients with 74 intracranial aneurysms treated with Guglielmi detachable coils. We used the unsubtracted image of the angiograms performed at the completion of any embolisation procedure and at follow-up as the plain radiographs. Recanalisation was considered if loosening, compaction or reorientation of the coil mass was apparent. TOF MRA was performed to assess the presence and size of a neck remnant. DSA was regarded as the definitive investigation. Comparison of the techniques showed good agreement as regards aneurysm recanalisation. MRA was more accurate than plain radiography and could replace DSA for long term follow- up. The initial follow-up examination should, however, include both modalities. In cases of contraindications or limitations to MRA, the interval between follow-up angiographic examinations could be increased if there is no change in the plain-film coil-mass appearances. (orig.)

  9. Long-term MRA follow-up after coiling of intracranial aneurysms: impact on mood and anxiety

    Energy Technology Data Exchange (ETDEWEB)

    Ferns, Sandra P.; Nieuwkerk, Pythia T.; Majoie, Charles B.L.M. [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Rooij, Willem Jan J. van [St. Elisabeth Ziekenhuis, Department of Radiology, Tilburg (Netherlands); Rinkel, Gabriel J.E. [University Medical Center, Department of Neurology, Rudolf Magnus Institute of Neuroscience, Utrecht (Netherlands)

    2011-05-15

    Magnetic resonance angiography (MRA) screening for recurrence of a coiled intracranial aneurysm and formation of new aneurysms long-term after coiling may induce anxiety and depression. In coiled patients, we evaluated effects on mood and level of anxiety from long-term follow-up MRA in comparison to general population norms. Of 162 patients participating in a long-term (>4.5 years) MRA follow-up after coiling, 120 completed the EQ-5D questionnaire, a visual analog health scale and a self-developed screening related questionnaire at the time of MRA. Three months later, the same questionnaires were completed by 100 of these 120 patients. Results were compared to general population norms adjusted for gender and age. Any problem with anxiety or depression was reported in 56 of 120 patients (47%; 95%CI38<->56%) at baseline and 42 of 100 patients (42%; 95%CI32<->52%) at 3 months, equally for screen-positives and -negatives. Compared to the reference population, participants scored 38% (95%CI9<->67%) and 27% (95%CI4<->50%) more often any problem with anxiety or depression. Three months after screening, 21% (20 of 92) of screen-negatives and 13% (one of eight) of screen-positives reported to be less afraid of subarachnoid hemorrhage (SAH) compared to before screening. One of eight screen-positives reported increased fear of SAH. Patients with coiled intracranial aneurysms participating in long-term MRA screening reported significantly more often to be anxious or depressed than a reference group. Screening did not significantly increase anxiety or depression temporarily. However, subjectively, patients did report an increase in anxiety caused by screening, which decreased after 3 months. (orig.)

  10. Long-term MRA follow-up after coiling of intracranial aneurysms: impact on mood and anxiety

    International Nuclear Information System (INIS)

    Magnetic resonance angiography (MRA) screening for recurrence of a coiled intracranial aneurysm and formation of new aneurysms long-term after coiling may induce anxiety and depression. In coiled patients, we evaluated effects on mood and level of anxiety from long-term follow-up MRA in comparison to general population norms. Of 162 patients participating in a long-term (>4.5 years) MRA follow-up after coiling, 120 completed the EQ-5D questionnaire, a visual analog health scale and a self-developed screening related questionnaire at the time of MRA. Three months later, the same questionnaires were completed by 100 of these 120 patients. Results were compared to general population norms adjusted for gender and age. Any problem with anxiety or depression was reported in 56 of 120 patients (47%; 95%CI3856%) at baseline and 42 of 100 patients (42%; 95%CI3252%) at 3 months, equally for screen-positives and -negatives. Compared to the reference population, participants scored 38% (95%CI967%) and 27% (95%CI450%) more often any problem with anxiety or depression. Three months after screening, 21% (20 of 92) of screen-negatives and 13% (one of eight) of screen-positives reported to be less afraid of subarachnoid hemorrhage (SAH) compared to before screening. One of eight screen-positives reported increased fear of SAH. Patients with coiled intracranial aneurysms participating in long-term MRA screening reported significantly more often to be anxious or depressed than a reference group. Screening did not significantly increase anxiety or depression temporarily. However, subjectively, patients did report an increase in anxiety caused by screening, which decreased after 3 months. (orig.)

  11. Large Residual Volume, Not Low Packing Density, Is the Most Influential Risk Factor for Recanalization after Coil Embolization of Cerebral Aneurysms

    Science.gov (United States)

    Sadato, Akiyo; Hayakawa, Motoharu; Adachi, Kazuhide; Nakahara, Ichiro; Hirose, Yuichi

    2016-01-01

    Background Tight coil packing with density of at least 20%–25% is known to be important for preventing recanalization after embolization of cerebral aneurysms. However, large aneurysms sometimes recanalize regardless of the packing density, suggesting that the absolute residual volume which is determined by aneurysm volume and packing density may be more important risk factor for recanalization. To validate this hypothesis, we analyzed the factors affecting the outcomes of treated aneurysms at our institute. Methods and Findings We included 355 small and large aneurysms. The following six factors were obtained from every case: aneurysm volume (mL), neck size (mm), packing density (%), residual volume (mL), rupture status at presentation, and stent assistance (with or without stent). The data were then subjected to multivariate logistic regression analysis to identify significant risk factors for recanalization. Recanalization occurred in 61 aneurysms (17.2%). Significant predictors for recanalization were aneurysm volume (odds ratio, 15.3; P < 0.001) and residual volume (odds ratio, 30.9; P < 0.001), but not packing density (odds ratio, 0.98; P = 0.341). These results showed that for each 0.1-mL increase in aneurysm volume and residual volume, the risk of recanalization increased by 1.3 times and 1.4 times, respectively. Conclusions The most influential risk factor for recanalization after coil embolization was residual volume, not packing density. The larger the aneurysm volume, the greater the packing density has to be to minimize the residual volume and risk of recanalization. Since tight coil packing has already been aimed, further innovation of coil property or embolization technique may be needed. Otherwise, different treatment modality such as flow diverter or parent artery occlusion may have to be considered. PMID:27153192

  12. Internal carotid artery aneurysms, cranial nerve dysfunction and headache: the role of deformation and pulsation

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Catarino, M.; Wikholm, G.; Svendsen, P. [Interventional Neuroradiology, Sahlgrenska Hospital, Goeteborg (Sweden); Frisen, L. [Ophthalmology Dept., Sahlgrenska Hospital, Goeteborg (Sweden); Elfverson, J. [Neurosurgery Dept., Sahlgrenska Hospital, Goeteborg (Sweden); Quiding, L. [Medical Physics and Biomedical Engineering Dept., Sahlgrenska Hospital, Goeteborg (Sweden)

    2003-04-01

    Cranial nerve dysfunction and headache may occur with unruptured aneurysms of the cavernous and supraclinoid portions of the internal carotid artery. Nerve deformation (mass effect) and transmitted pulsations have been suggested as pathogenetic mechanisms. Differentiation may be possible by studying effects of endovascular treatment with Guglielmi detachable coils. Symptoms and signs of cranial neuropathy were retrospectively contrasted with angiographic aneurysm volumes before and after treatment in 10 patients. Mean follow-up was 36 months. Symptoms improved in three of four patients with cranial nerve dysfunction and in all patients with headache: None of the other patients, one with cranial nerve dysfunction, and three who were asymptomatic, developed any new symptoms after treatment. Aneurysm volume ranged from 0.1 to 2.7 cm{sup 3} before and 0.2 to 5.7 cm{sup 3} after treatment; the size thus increased by 15 to 110%, a change which was statistically significant (P = 0.004). The consistent increase in aneurysm volume with treatment is not associated with clinical deterioration, suggesting that deformation and displacement play a minor role in cranial neuropathy and that transmitted pulsations may be more important. (orig.)

  13. Internal carotid artery aneurysms, cranial nerve dysfunction and headache: the role of deformation and pulsation

    International Nuclear Information System (INIS)

    Cranial nerve dysfunction and headache may occur with unruptured aneurysms of the cavernous and supraclinoid portions of the internal carotid artery. Nerve deformation (mass effect) and transmitted pulsations have been suggested as pathogenetic mechanisms. Differentiation may be possible by studying effects of endovascular treatment with Guglielmi detachable coils. Symptoms and signs of cranial neuropathy were retrospectively contrasted with angiographic aneurysm volumes before and after treatment in 10 patients. Mean follow-up was 36 months. Symptoms improved in three of four patients with cranial nerve dysfunction and in all patients with headache: None of the other patients, one with cranial nerve dysfunction, and three who were asymptomatic, developed any new symptoms after treatment. Aneurysm volume ranged from 0.1 to 2.7 cm3 before and 0.2 to 5.7 cm3 after treatment; the size thus increased by 15 to 110%, a change which was statistically significant (P = 0.004). The consistent increase in aneurysm volume with treatment is not associated with clinical deterioration, suggesting that deformation and displacement play a minor role in cranial neuropathy and that transmitted pulsations may be more important. (orig.)

  14. Coil treatment of a fusiform upper basilar trunk aneurysm with a combination of ''kissing'' neuroform stents, TriSpan-, 3D- and fibered coils, and permanent implantation of the microguidewires

    Energy Technology Data Exchange (ETDEWEB)

    Henkes, H.; Mariushi, W.; Miloslavski, E.; Brew, S.; Kuehne, D. [Klinik fuer Radiologie und Neuroradiologie, Alfried Krupp Krankenhaus, Alfried Krupp Strasse 21, 45117, Essen (Germany); Kirsch, M. [Zentrum Radiologie, Abteilung fuer Diagnostische und Interventionelle Radiologie, Ernst Moritz Arndt Universitaet Greifswald, Greifswald (Germany)

    2004-06-01

    Endovascular coil occlusion of fusiform intracranial aneurysms without sacrifice of the parent artery can be technically challenging. Bridging of wide aneurysm necks with stents is common practice for side-wall aneurysms but is less frequently used for bifurcation aneurysms. We describe the technical aspects of the successful coil occlusion of a fusiform aneurysm of the upper basilar trunk, with preservation of the parent vessel. The procedure comprised the following steps: (a) stenting of the left V1- and proximal V2 segments; (b) simultaneous deployment of two Neuroform stents from both P1 segments down to the basilar artery (''kissing'' stents) (c) using a TriSpan device to hold (d) three-dimensional electrolytically detachable coils in place and (e) filling the aneurysmal lumen mainly with fibered electrolytically detachable coils; and finally (f) cutting the extracorporeal part of both microguidewires below the skin level in both groins, leaving the microguidewires as they were used for the deployment of the stents in place, thus reaching from both P2 segments down to the basilar artery and further proximally. (orig.)

  15. Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling

    Energy Technology Data Exchange (ETDEWEB)

    Westerlaan, H.E.; Gravendeel, J.; Fiore, D.; Oudkerk, M. [University Medical Center Groningen, Department of Radiology, Post Box 30.001, Groningen (Netherlands); Metzemaekers, J.D.M.; Groen, R.J.M.; Mooij, J.J.A. [University Medical Center Groningen, Department of Neurosurgery, Post Box 30.001, Groningen (Netherlands)

    2007-12-15

    We sought to establish whether CT angiography (CTA) can be applied to the planning and performance of clipping or coiling in ruptured intracranial aneurysms without recourse to intraarterial digital subtraction angiography (IA-DSA). Over the period April 2003 to January 2006 in all patients presenting with a subarachnoid haemorrhage CTA was performed primarily. If CTA demonstrated an aneurysm, coiling or clipping was undertaken. IA-DSA was limited to patients with negative or inconclusive CTA findings. We compared CTA images with findings at surgery or coiling in patients with positive CTA findings and in patients with negative and inconclusive findings in whom IA-DSA had been performed. In this study, 224 consecutive patients (mean age 52.7 years, 135 women) were included. In 133 patients (59%) CTA demonstrated an aneurysm, and CTA was followed directly by neurosurgical (n = 55) or endovascular treatment (n = 78). In 31 patients (14%) CTA findings were categorized as inconclusive, and in 60 (27%) CTA findings were negative. One patient received surgical treatment on the basis of false-positive CTA findings. In 17 patients in whom CTA findings were inconclusive, IA-DSA provided further diagnostic information required for correct patient selection for any therapy. Five ruptured aneurysms in patients with a nonperimesencephalic SAH were negative on CTA, and four of these were also false-negative on IA-DSA. On a patient basis the positive predictive value, negative predictive value, sensitivity, specificity and accuracy of CTA for symptomatic aneurysms were 99%, 90%, 96%, 98% and 96%, respectively. CTA should be used as the first diagnostic modality in the selection of patients for surgical or endovascular treatment of ruptured intracranial aneurysms. If CTA renders inconclusive results, IA-DSA should be performed. With negative CTA results the complementary value of IA-DSA is marginal. IA-DSA is not needed in patients with negative CTA and classic perimesencephalic

  16. Contrast-enhanced 3D MR imaging after coil embolization of visceral artery aneurysms. Experimental optimization of imaging parameters

    International Nuclear Information System (INIS)

    We assessed optimal imaging conditions for contrast-enhanced 3-dimensional (3D) magnetic resonance (MR) imaging in follow-up examinations after coil embolization of visceral artery aneurysms. In a phantom encapsulating samples with varying concentrations of gadolinium (Gd) and baby oil, we fixed imaging time, field of vision (FOV), and matrix and changed k-space filling methods (centric and volumetric interpolated breath-hold examination [VIBE]) and flip angle (FA) values to compare signal strength, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). We also studied artifacts in a home-made phantom that contained a platinum coil. We visually compared resolution performance (N=5) using a profile curve. We obtained the best results for signal strength, SNR, and CNR at FA of 24deg for VIBE and 18deg for centric and observed no differences in artifacts. For optimal FA value, VIBE provided better results across all items-signal strength, SNR, CNR, and resolution performance. Although it is necessary to estimate hemodynamics with a test injection for contrast-enhanced 3D MR imaging used during follow-up examinations after coil embolization of visceral artery aneurysms, optimal imaging results are obtained at FA of 24 deg for VIBE. (author)

  17. Interventional embolization with coils in the way of 'sandwich pattern' for the treatment of large splenic aneurysms: a therapeutic analysis of six cases

    International Nuclear Information System (INIS)

    Objective: To assess the feasibility and effectiveness of interventional embolization with coils in the way of 'sandwich pattern' for the treatment of large splenic aneurysms. Methods: From March 2000 to December 2008, the authors had treated six patients with large splenic aneurysms (4 females and 2 males; mean age 54 years) by means of interventional embolization with coils in the way of 'sandwich pattern'. There were 5 true splenic aneurysms, of which 2 were located at the origin of the splenic artery and 3 at the middle segment of the splenic artery. The remaining one lesion was a pseudo aneurysm that was located at the middle segment of the splenic artery. The diagnosis was confirmed by colour-Doppler ultrasonography and/or CT-angiography in all patients. Interventional embolization with coils in the way of 'sandwich pattern' was performed in all patients. Both the efferent and afferent arteries of the splenic aneurysms were embolized successively, the procedure was thus called 'sandwich pattern' way. The patients were followed up for 1 to 9 years. Based on CT angiographic manifestations, colour-Doppler ultrasound findings and clinical conditions the therapeutic results were evaluated. Results: All the six splenic aneurysms were successfully isolated by interventional embolization in 'sandwich pattern' way, with no occurrence of severe complications. One patient died from malignant bone tumor four months after the treatment. The followup CT imaging showed no signs of re-canalization of the lesions in other 5 cases, although small-sized, fan-shaped splenic infarction was seen in 2 cases. Conclusion: Interventional embolization with coils in the way of 'sandwich pattern' is a safe and effective technique for the treatment of splenic aneurysms, especially valuable when the aneurysm is a large one. (authors)

  18. Subarachnoid Hemorrhage from a Dissecting Aneurysm of the Posterior Cerebral Artery in a Child : Rebleeding after Stent-Assisted Coiling Followed by Stent-Within-Stent Technique

    OpenAIRE

    Lee, Ji Yeoun; Kwon, Bae Ju; Kang, Hyun-Seung; Wang, Kyu-Chang

    2011-01-01

    Pediatric patients with dissecting aneurysms usually present with ischemia rather than bleeding. We report a case of a 15-year-old boy with a dissecting aneurysm of the posterior cerebral artery (PCA) presenting with hemorrhage. He was first treated with stent-assisted coil embolization, in an attempt to avoid trapping of the PCA and preserve the perforators. After the procedure, he recovered well from general anesthesia, but rebleeding occurred from the same lesion 6 hours after the procedur...

  19. Treatment of cerebral aneurysms-surgical clipping or endovascular coiling: the guiding principles.

    Science.gov (United States)

    Shivashankar, Ravishankar; Miller, Timothy R; Jindal, Gaurav; Simard, J Marc; Aldrich, E Francois; Gandhi, Dheeraj

    2013-11-01

    Cerebral aneurysms represent common intracranial vascular lesions encountered in neurosurgical practice. The clinical presentation is varied, ranging from asymptomatic lesions to those presenting with catastrophic intracranial hemorrhage. Aneurysm treatment has been a rapidly evolving field with numerous technical innovations, especially in the last two decades. Selecting the appropriate treatment can be a complex process that involves integration of information regarding the patient's clinical presentation, associated comorbidities, the aneurysm's morphological characteristics, safety and efficacy of the treatment options and skill and experience of available practitioners, amongst others. In this article, we review each of these factors and appraise the available scientific evidence in an effort to facilitate decision making in the treatment of cerebral aneurysms. The treatment of intracranial aneurysms is best performed at high volume centers that utilize a multidisciplinary, team-based approach. PMID:24504611

  20. Acceleration of aneurysm healing by P(DLLA-co-TMC)-coated coils enabling the controlled release of vascular endothelial growth factor.

    Science.gov (United States)

    Wang, Qiujing; Gao, Yuyuan; Sun, Xinlin; Ji, Bin; Cui, Xubo; Liu, Yaqi; Zheng, Tao; Chen, Chengwei; Jiang, Xiaodan; Zhu, Aiping; Quan, Daping

    2014-08-01

    Since the introduction of the detachable coil in endovascular treatment of intracranial aneurysms, the in-hospital mortality rate has been significantly decreased. Recurrence of the aneurysm remains the major drawback of using detachable coils. We prepared a bioactive coil coated with poly(d,l-lactide)-7co-(1,3-trimethylene carbonate) (P(DLLA-co-TMC)), a novel copolymer for controlling the release of vascular endothelial growth factor (VEGF). Platinum coils were prepared by successive coating with cationic P(DLLA-co-TMC) and anionic heparin. Then, recombinant human VEGF-165 (rhVEGF) was immobilized by affinity binding to heparin. The morphological characteristics and sustained in vitro release of rhVEGF were examined using scanning electron microscopy and enzyme-linked immunosorbent assay, respectively. The efficacy of these novel coils modified by P(DLLA-co-TMC)/rhVEGF was tested using a common carotid artery aneurysm model in rats. Experimental aneurysms were embolized with unmodified, P(DLLA-co-TMC)/heparin-coated or P(DLLA-co-TMC)/rhVEGF-coated platinum coils (n = 18). The coils were removed on days 15, 30 and 90 after insertion, and the histological and immunohistochemical analysis of factor VIII was performed to confirm the presence of endothelial cells in the organized area. In addition, the controlled in vivo release of VEGF was confirmed by Western blotting analysis. The release of VEGF tended to increase during the whole period and no burst release was observed. In the group treated with P(DLLA-co-TMC)/rhVEGF-coated platinum coils, clot organization and endothelial cell proliferation were accelerated. The immunohistochemistry study showed that the expression of factor VIII was found in the P(DLLA-co-TMC)/rhVEGF-coated coil group but not in the other two groups. Furthermore, Western blotting analysis confirmed that the major released VEGF in the aneurysm sac was from the P(DLLA-co-TMC)/VEGF-coated coil. P(DLLA-co-TMC)/rhVEGF-coated platinum coils can

  1. Acceleration of aneurysm healing by P(DLLA-co-TMC)-coated coils enabling the controlled release of vascular endothelial growth factor

    International Nuclear Information System (INIS)

    Since the introduction of the detachable coil in endovascular treatment of intracranial aneurysms, the in-hospital mortality rate has been significantly decreased. Recurrence of the aneurysm remains the major drawback of using detachable coils. We prepared a bioactive coil coated with poly(d,l-lactide)-7co-(1,3-trimethylene carbonate) (P(DLLA-co-TMC)), a novel copolymer for controlling the release of vascular endothelial growth factor (VEGF). Platinum coils were prepared by successive coating with cationic P(DLLA-co-TMC) and anionic heparin. Then, recombinant human VEGF-165 (rhVEGF) was immobilized by affinity binding to heparin. The morphological characteristics and sustained in vitro release of rhVEGF were examined using scanning electron microscopy and enzyme-linked immunosorbent assay, respectively. The efficacy of these novel coils modified by P(DLLA-co-TMC)/rhVEGF was tested using a common carotid artery aneurysm model in rats. Experimental aneurysms were embolized with unmodified, P(DLLA-co-TMC)/heparin-coated or P(DLLA-co-TMC)/rhVEGF-coated platinum coils (n = 18). The coils were removed on days 15, 30 and 90 after insertion, and the histological and immunohistochemical analysis of factor VIII was performed to confirm the presence of endothelial cells in the organized area. In addition, the controlled in vivo release of VEGF was confirmed by Western blotting analysis. The release of VEGF tended to increase during the whole period and no burst release was observed. In the group treated with P(DLLA-co-TMC)/rhVEGF-coated platinum coils, clot organization and endothelial cell proliferation were accelerated. The immunohistochemistry study showed that the expression of factor VIII was found in the P(DLLA-co-TMC)/rhVEGF-coated coil group but not in the other two groups. Furthermore, Western blotting analysis confirmed that the major released VEGF in the aneurysm sac was from the P(DLLA-co-TMC)/VEGF-coated coil. P(DLLA-co-TMC)/rhVEGF-coated platinum coils can

  2. Time-of-flight magnetic resonance angiography for follow-up of coil embolization with enterprise stent intracranial aneurysm: Usefulness of source images

    International Nuclear Information System (INIS)

    The aim of this study was to determine the interobserver and intermodality agreement in the interpretation of time-of-flight (TOF) MR angiography (MRA) for the follow-up of coiled intracranial aneurysms with the Enterprise stent. Two experienced neurointerventionists independently reviewed the follow-up MRA studies of 40 consecutive patients with 44 coiled aneurysms. All aneurysms were treated with assistance from the Enterprise stent and the radiologic follow-up intervals were greater than 6 months after the endovascular therapy. Digital subtraction angiography (DSA) served as the reference standard. The degree of aneurysm occlusion was determined by an evaluation of the maximal intensity projection (MIP) and source images (SI) of the TOF MRA. The capability of the TOF MRA to depict the residual flow within the coiled aneurysms and the stented parent arteries was compared with that of the DSA. DSA showed stable occlusions in 25 aneurysms, minor recanalization in 8, and major recanalization in 11. Comparisons between the TOF MRA and conventional angiography showed that the MIP plus SI had almost perfect agreement (κ = 0.892, range 0.767 to 1.000) and had better agreement than with the MIP images only ((κ = 0.598, range 0.370 to 0.826). In-stent stenosis of more than 33% was observed in 5 cases. Both MIP and SI of the MRA showed poor depiction of in-stent stenosis compared with the DSA. TOF MRA seemed to be reliable in screening for aneurysm recurrence after coil embolization with Enterprise stent assistance, especially in the evaluation of the SI, in addition to MIP images in the TOF MRA.

  3. Clinical course of a partially thrombosed, symptomatic aneurysm of the basilar artery tip with partial recanalization subsequent to coiling; Verlaufsbeschreibung eines teilthrombosierten symptomatischen Basilariskopfaneurysmas mit teilweiser Rekanalisierung nach Coiling

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, V. [Universitaet des Saarlandes, Abteilung fuer Neuroradiologie, Homburg (Germany); Klinikum Saarbruecken, Institut fuer bildgebende Diagnostik und Interventionen, Saarbruecken (Germany); Axmann, C.; Reith, W. [Universitaet des Saarlandes, Abteilung fuer Neuroradiologie, Homburg (Germany)

    2006-05-15

    A 72-year-old patient was referred to the neuroradiological department for diagnostic angiography. She was suffering from vertigo and double vision. Magnetic resonance imaging performed elsewhere had demonstrated a giant aneurysm of the basilar artery tip 2 cm in diameter. Angiography revealed a large aneurysm with a broad neck that was partially thrombosed, which precluded closure by coiling. Neurosurgical management by clipping also appeared to be unsuitable because of the proximity to the cerebrum. The decision was reached to proceed expectantly by closely monitoring the clinical course. When the aneurysm increased in size in the ensuing weeks, coiling was performed successfully. Angiographic follow-up showed reperfusion of the aneurysm neck and closure was again achieved by repeat coiling. Reperfusion is not a rare complication following coiling and often necessitates renewed intervention. (orig.) [German] Eine 72-jaehrige Patientin wurde in der neuroradiologischen Abteilung zur diagnostischen Angiographie vorgestellt. Sie litt unter Schwindel und Doppelbildern. Eine auswaertige MR-Untersuchung des Gehirns zeigte ein Riesenaneurysma des Basilariskopfes mit einem Durchmesser von 2 cm. Die Angiographie zeigte ein grosses Aneurysma mit breitem Hals, das teilweise thrombosiert war. Dies liess einen Verschluss durch Coiling nicht zu. Eine neurochirurgische Behandlung durch Klippung erschien wegen der Naehe zum Mittelhirn ebenfalls ungeeignet. Man einigte sich auf ein abwartendes Vorgehen durch eine engmaschige Verlaufsbeobachtung. Als das Aneurysma in den folgenden Wochen eine Groessenzunahme zeigte, wurde erfolgreich ein Coiling durchgefuehrt. Eine angiographische Verlaufskontrolle zeigte eine Reperfusion des Aneurysmahalses. Erneut konnte ein Verschluss durch Coiling erzielt werden. Eine Reperfusion ist keine seltene Komplikation nach Coiling, die oft eine erneute Intervention erfordert. (orig.)

  4. Persistent neurological deficit from iodinated contrast encephalopathy following intracranial aneurysm coiling. A case report and review of the literature.

    LENUS (Irish Health Repository)

    Leong, S

    2012-03-01

    Neurotoxicity from iodinated contrast agents is a known but rare complication of angiography and neurovascular intervention. Neurotoxicity results from contrast penetrating the blood-brain barrier with resultant cerebral oedema and altered neuronal excitability. Clinical effects include encephalopathy, seizures, cortical blindness and focal neurological deficits. Contrast induced encephalopathy is extensively reported as a transient and reversible phenomenon. We describe a patient with a persistent motor deficit due to an encephalopathy from iodinated contrast media administered during cerebral aneurysm coiling. This observation and a review of the literature highlights that contrast-induced encephalopathy may not always have a benign outcome and can cause permanent deficits. This potential harmful effect should be recognised by the angiographer and the interventionalist.

  5. Cost-Effectiveness Analysis of Endovascular Coiling versus Neurosurgical Clipping for Intracranial Aneurysms in Republic of Korea

    Science.gov (United States)

    Shin, Shang Hun; Suh, Sang Hyun; Kim, Bum-soo; Rho, Myung Ho

    2016-01-01

    Purpose The International Subarachnoid Aneurysm Trial (ISAT) revealed that in ruptured intracranial aneurysms (RA), endovascular coiling (EC) yields better clinical outcomes than neurosurgical clipping (NC) at 1 year. In unruptured aneurysms (UIA), EC is being increasingly used as an alternative to NC due to patients' preference. There is a lot of difference in treatment cost (EC vs. NC) between countries. There is one recently published study dealing with the comparative cost analysis only in UIAs in South Korea. But it is a hospital-based study. So, the authors performed a nation-wide cost effective comparison in our country. Materials and Methods This study was a retrospective analysis of healthcare big data open systems in Health Insurance Review & Assessment Service (HIRA). Hospital cost data of the recent 5 years (from January 2010 to December 2014) were analyzed according to patients' age and sex and the presence of subarachnoid hemorrhage. Results When comparing the total hospital costs for NC of a UIA (n=13,756) and EC of a UIA (n=17,666), NC [mean±standard deviation (SD): ₩7,987,179±3,855,029] resulted in significantly lower total hospital costs than EC [₩10,201,645±5,001,626, pcosts for NC of a RA (n=7,293) and EC of a RA (n=6,954), NC [₩13,914,993±6,247,914] resulted in significantly lower total hospital costs than EC [₩16,702,446±7,841,141, pcosts for the NC of both UIAs and RAs were found to be lower than those for EC in South Korea.

  6. Comparison between Willis covered stent placement and coil embolization in the treatment of cranial internal carotid artery aneurysm: a nonrandomized prospective trial

    International Nuclear Information System (INIS)

    Objective: To evaluate the clinical results of Willis covered stent implantation and coil embolization in the treatment of cranial internal carotid artery (CICA) aneurysm. Methods: Eighty-nine patients with CICA aneurysms were selected for treatment with Willis covered stents (n=43, group A) or coil embolization (n=46, group B) according to the patients' will. Data on the technical success, initial procedure time and in-hospital interval, initial and final angiographic results, mortality, morbidity, and final clinical outcomes were collected and analyzed for the two groups at 6 months post-procedure. Results: Endovascular covered stent placement and coil embolization were technically successful in all patients, except for one patient in group A. The initial angiographic results showed complete occlusion in 34 patients of group A (81% , 95% CI: 69%, 93%) and 24 patients of group B (52%, 95% CI: 37%, 67%) (P< 0.05). The final angiographic results indicated complete occlusion in 39 patients of group A (39/41, 95%, 95% CI: 88%, 102%) and 22 patients of group B (22/45, 49%, 95% CI: 34%, 64%, P<0.01). The average procedure time was (103±13) min in group A and (143±39) min in group B (P<0.01). No significant differences were seen between the two groups in technique success, mortality, morbidity, or final clinical outcomes. Conclusion: In this nonrandomized, prospective trial, CICA aneurysm treatment with covered stents yielded midterm angiographic results that were superior to those of coil embolization. (authors)

  7. Follow-up of coiled intracranial aneurysms: comparison of 3D time-of-flight and contrast-enhanced magnetic resonance angiography at 3T in a large, prospective series

    International Nuclear Information System (INIS)

    To compare 3D-TOF magnetic resonance angiography (MRA) and contrast-enhanced MRA (CE-MRA) sequences at 3T in the follow-up of coiled aneurysms with digital subtracted angiography (DSA) as the gold standard. DSA, 3D-TOF and CE-MRA were performed in a prospective series of 126 aneurysms in 96 patients (57 female, 39 male; age: 25-75 years, mean: 51.3 ± 11.3 years). The quality of aneurysm occlusion was assessed independently and anonymously by a core laboratory. Using DSA (gold standard technique), total occlusion was depicted in 57 aneurysms (45.2%), neck remnant in 34 aneurysms (27.0%) and aneurysm remnant in 35 aneurysms (27.8%). Sensitivity, specificity, positive predictive value and negative predictive value were very similar with 3D-TOF and CE-MRA. Visibility of coils was much better with 3D-TOF (95.2%) than with CE-MRA (23.0%) (P < 0.001). Also, substantial artefacts were less frequent with 3D-TOF (4.0%) than with CE-MRA (11.9%; P = 0.012). In this large prospective series of patients with coiled aneurysms, at 3T 3D-TOF MRA was equivalent to CE-MRA for the evaluation of aneurysm occlusion, but coil visibility was superior at 3D-TOF. Thus the use of 3D-TOF at 3T is recommended for the follow-up of coiled intracranial aneurysms. (orig.)

  8. Follow-up of coiled intracranial aneurysms: comparison of 3D time-of-flight and contrast-enhanced magnetic resonance angiography at 3T in a large, prospective series

    Energy Technology Data Exchange (ETDEWEB)

    Pierot, Laurent [University of Reims, Department of Radiology, Maison Blanche Hospital, Reims (France); Hopital de la Maison Blanche - CHU, Service de radiologie, Reims (France); Portefaix, Christophe [University of Reims, Department of Radiology, Maison Blanche Hospital, Reims (France); University of Reims, CReSTIC SIC EA3804, Reims (France); Boulin, Anne [Foch Hospital, Department of Neuroradiology, Suresnes (France); Gauvrit, Jean-Yves [University of Rennes, Department of Radiology, CHU Rennes, Rennes (France)

    2012-10-15

    To compare 3D-TOF magnetic resonance angiography (MRA) and contrast-enhanced MRA (CE-MRA) sequences at 3T in the follow-up of coiled aneurysms with digital subtracted angiography (DSA) as the gold standard. DSA, 3D-TOF and CE-MRA were performed in a prospective series of 126 aneurysms in 96 patients (57 female, 39 male; age: 25-75 years, mean: 51.3 {+-} 11.3 years). The quality of aneurysm occlusion was assessed independently and anonymously by a core laboratory. Using DSA (gold standard technique), total occlusion was depicted in 57 aneurysms (45.2%), neck remnant in 34 aneurysms (27.0%) and aneurysm remnant in 35 aneurysms (27.8%). Sensitivity, specificity, positive predictive value and negative predictive value were very similar with 3D-TOF and CE-MRA. Visibility of coils was much better with 3D-TOF (95.2%) than with CE-MRA (23.0%) (P < 0.001). Also, substantial artefacts were less frequent with 3D-TOF (4.0%) than with CE-MRA (11.9%; P = 0.012). In this large prospective series of patients with coiled aneurysms, at 3T 3D-TOF MRA was equivalent to CE-MRA for the evaluation of aneurysm occlusion, but coil visibility was superior at 3D-TOF. Thus the use of 3D-TOF at 3T is recommended for the follow-up of coiled intracranial aneurysms. (orig.)

  9. Aneurysm of an Anomalous Systemic Artery Supplying the Normal Basal Segments of the Left Lower Lobe: Endovascular Treatment with the Amplatzer Vascular Plug II and Coils

    International Nuclear Information System (INIS)

    An anomalous systemic artery originating from the descending thoracic aorta supplying the normal basal segments of the lower lobe of the left lung without sequestration is a rare congenital anomaly. The published surgical treatments include lobectomy, segmentectomy, anastomosis, and ligation. In addition, endovascular treatment with coils has been reported. A second-generation occluder, the Amplatzer Vascular Plug II (AVP II), has a central plug and two occlusion disks and a finer, more densely woven nitinol wire, thus enabling faster embolization. This published case is the first successful occlusion of an aneurysm of an anomalous systemic artery with the AVP II and fibered coils, with 10 months of follow-up.

  10. Thromboembolic events associated with single balloon-, double balloon-, and stent-assisted coil embolization of asymptomatic unruptured cerebral aneurysms: evaluation with diffusion-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takigawa, Tomoji; Suzuki, Kensuke; Sugiura, Yoshiki; Suzuki, Ryotaro; Takano, Issei; Shimizu, Nobuyuki; Tanaka, Yoshihiro; Hyodo, Akio [Dokkyo Medical University Koshigaya Hospital, Department of Neurosurgery, Koshigaya, Saitama (Japan)

    2014-12-15

    The introduction of the balloon remodeling and stent-assisted technique has revolutionized the approach to coil embolization for wide-neck aneurysms. The purpose of this study was to determine the frequency of thromboembolic events associated with single balloon-assisted, double balloon-assisted, and stent-assisted coil embolization for asymptomatic unruptured aneurysms. A retrospective review was undertaken by 119 patients undergoing coiling with an adjunctive technique for unruptured saccular aneurysms (64 single balloon, 12 double balloon, 43 stent assisted). All underwent diffusion-weighted imaging (DWI) within 24 h after the procedure. DWI showed hyperintense lesions in 48 (40 %) patients, and ten (21 %) of these patients incurred neurological deterioration (permanent, two; transient, eight). Hyperintense lesions were detected significantly more often in procedures with the double balloon-assisted technique (7/12, 58 %) than with the single balloon-assisted technique (16/64, 25 %, p = 0.05). Occurrence of new lesions was significantly higher with the use of stent-assisted technique (25/43, 58 %) than with the single balloon-assisted technique (p = 0.001). Symptomatic ischemic rates were similar between the three groups. The increased number of microcatheters was significantly related to the DWI abnormalities (two microcatheters, 15/63 (23.8 %); three microcatheters, 20/41 (48.8 %) (p = 0.008); four microcatheters, 12/15 (80 %) (p = 0.001)). Thromboembolic events detected on DWI related to coil embolization for unruptured aneurysms are relatively common, especially in association with the double balloon-assisted and stent-assisted techniques. Furthermore, the number of microcatheters is highly correlated with DWI abnormalities. The high rate of thromboembolic events suggests the need for evaluation of platelet reactivity and the addition or change of antiplatelet agents. (orig.)

  11. The Role of Filtration in Maintaining Clean Heat Exchanger Coils

    Energy Technology Data Exchange (ETDEWEB)

    Li Yang; James E. Braun; Eckhard A. Groll

    2004-06-30

    The main purpose of the study was to investigate the role of filtration in maintaining clean heat exchanger coils and overall performance. Combinations of 6 different levels of filtration (MERV 14, 11, 8, 6, 4, and no filter) and 4 different coils (an eight-row lanced-fin coil, HX8L), (an eight-row wavy-fin coil, HX8W), (a four-row lanced-fin coil, HX4L) and (a two-row lanced-fin coil, HX2L) were tested at 4 different air velocities (1.52, 2.03, 2.54,3.05 m/s (300, 400, 500, 600 ft/min)). The fouled conditions were obtained after injection of 600 grams of ASHRAE standard dust upstream of the filter/coil combination. This magnitude of dust is representative of a year of normal operation for an air conditioning system. The air-side pressure drops of the coils and filters and air-side heat transfer coefficients of the coils were determined from the measurements under the clean and fouled conditions. Depending upon the filter and coil test, the coil pressure drops increased in the range of 6%-30% for an air velocity at 2.54 m/s (500 ft/min). The impact was significantly greater for tests performed without a filter. The largest relative effect of fouling on pressure drop occurs for coils with fewer rows and having lanced fins. Coils with a greater number of rows can hold more dust so that a fixed amount of dust has a relatively smaller impact. The impact of fouling on air-side heat transfer coefficients was found to be relatively small. In some cases, heat transfer was actually enhanced due to additional turbulence caused by the presence of dust. The experimental results for pressure drops and heat transfer coefficients were correlated and the correlations were implemented within computer models of prototypical rooftop air conditioners and used to evaluate the impact of fouling on cooling capacity and EER. The equipment cooling capacity is reduced with fouling primarily because of a decrease in air flow due to the increase pressure drop rather than due to changes in h

  12. The ability of plain radiography to predict intracranial aneurysm occlusion instability during follow-up of endosaccular treatment with Gugliemi detachable coils

    International Nuclear Information System (INIS)

    Incomplete occlusion of an intracranial aneurysm at follow-up after treatment with Gugliemi detachable coils (GDC) increases the risk of rebleeding and serial angiographic monitoring is therefore currently indicated. We aimed to determine if a change in the plain radiographic appearances of the GDC ball could accurately predict the presence of unstable angiographic occlusion. Paired GDC radiographs (in two planes) and cerebral angiograms, performed immediately after treatment and at follow-up or at two consecutive follow-up examinations, were retrospectively compared. Radiographs were assessed for the radiographic change (loosening, compaction or reorientation) in the coil-ball and angiograms for unstable aneurysm occlusion (neck recurrence or deteriorating occlusion). We compared 49 paired films from 38 patients. Radiographic change in the coil ball had a negative predictive value of 96 %, positive predictive value of 57 % and accuracy of 76 % for the presence of angiographic aneurysm instability. It may be possible to increase the interval between follow-up angiographic examinations after GDC treatment safely if there is no change in the radiographic appearances in two planes. (orig.)

  13. A critical role for proinflammatory behavior of smooth muscle cells in hemodynamic initiation of intracranial aneurysm.

    Directory of Open Access Journals (Sweden)

    Max Mandelbaum

    Full Text Available BACKGROUND: Intracranial aneurysm initiation is poorly understood, although hemodynamic insult is believed to play an important role in triggering the pathology. It has recently been found in a rabbit model that while macrophages are absent during hemodynamic aneurysm initiation, matrix metalloproteinases (MMPs are elevated and co-localize with smooth muscle cells (SMCs. This study investigates whether SMCs play a mechanistic role in aneurysm initiation triggered by hemodynamics. METHODS: Aneurysmal damage was induced at the basilar terminus via bilateral common carotid artery ligation in rabbits (n = 45, plus 7 sham controls. 16 ligated rabbits were treated with doxycycline to inhibit MMPs, 7 received clodronate liposomes to deplete circulating monocytes, and the rest received no drug. Effects of the treatments on aneurysm development were assessed histologically 5 days and 6 months after ligation. MMP production and expression of inflammatory markers by SMCs was monitored by immunohistochemistry and in situ hybridization. RESULTS: Treatment with doxycycline attenuated aneurysmal development examined at 5 days and 6 months, suggesting that MMPs contribute to aneurysm initiation. However, systemic depletion of macrophages did not decrease MMPs or suppress aneurysmal development. Immunofluorescence showed that during aneurysm initiation MMP-2 and MMP-9 were distributed in SMCs, and in situ hybridization indicated that they were transcribed by SMCs. In regions of early aneurysmal lesion, SMCs exhibited decreased expression of smooth muscle actin and increased NF-κB and MCP-1 expressions. CONCLUSIONS: During aneurysm initiation triggered by hemodynamics, SMCs rather than macrophages are responsible for MMP production that is critical for aneurysmal lesion development. These SMCs exhibit proinflammatory behavior.

  14. Interventional therapy of huge aneurysm

    International Nuclear Information System (INIS)

    Objective: To evaluate the methods and the efficacy of interventional therapy for huge aneurysm. Methods: Seven patients with huge aneurysm including 2 with pulmonary aneurysm, 2 with renal aneurysm, 1 with humeral artery aneurysm, 1 with right common iliac artery aneurysm, 1 with right internal iliac artery aneurysm. Among these, 5 were true aneurysm, and 2 were pseudoaneurysms caused by congenital, trauma, arteriosclerosis. Three patients were treated with endovascular covered stent graft and 2 patients with embolization containing metallic coils. Two patients were treated with partial aneurysm and feeding artery trunk embolization with metallic coils. Results: All 7 patients were successful carried out the interventional therapy with successful rate of 100%. Six aneurysms were completely obstructed with disappearance of symptoms and signs. One died of aneurysm rupture. No other complication occurred. Conclusion: Interventional therapy for huge aneurysm is an effective method. (authors)

  15. Postoperative alopecia in five patients after treatment of aneurysm rupture with a guglielmi detachable coil. Pressure alopecia, radiation induced, or both?

    International Nuclear Information System (INIS)

    Postoperative pressure alopecia is an uncommon complication of long anesthetic surgical procedures, typically affecting the occiput and resulting from pressure-induced tissue hypoxia. Generally, it develops after procedures of long duration, of more than four hours. Most alopecia is transient, but a few cases are permanent. Guglielmi detachable coil (GDG) coiling is a procedure guided by fluoroscopy that fills an intracranial aneurysm. Our cases were characterized by an unusual distribution of alopecia, short duration of procedure, and radiation exposure. The alopecic lesions of our patients were located on the temporal scalp as well as the occipital scalp. The total time of anesthesia was relatively short, two to three hours. During the procedure, these patients were exposed to ionizing radiation (over 2 Gy). These cases are different from previous reports in that the duration of the procedure was short, the temporal scalp was affected in addition to the occipital scalp, and the pathology occurred after GDC coiling. (author)

  16. Wingspan stent-assisted coiling of intracranial aneurysms with symptomatic parent artery stenosis: Experience in 35 patients with mid-term follow-up results

    International Nuclear Information System (INIS)

    Background: There is a potential risk of aneurysm rupture after parent artery revascularization because of increased blood flow. The purpose of this study is to assess the efficacy and safety of Wingspan stent-assisted coil embolization in the treatment of intracranial aneurysms with symptomatic parent artery stenosis. Methods: Thirty-five consecutive patients (19 men, 16 women; age range, 48–79 years; mean age, 60.4 years) harboring 35 unruptured wide-necked or fusiform intracranial aneurysms (mean size 6.8 mm; range 2.5–18 mm.) with symptomatic parent artery stenosis (mean degree 71.1%; range 50–92%) were treated with the Wingspan stent-assisted coiling. Twenty-four lesions were located in the anterior circulation and eleven in the posterior circulation. Patients were premedicated with antiplatelet therapy consisting of aspirin 300 mg and clopidogrel 75 mg for at least 3 days before the procedure. Following pre-dilatation and stent placement, a coiling microcatheter entered the aneurysm through the interstices of the stent, and then coiling was performed. After the procedure, clopidogrel 75 mg daily was recommended for an additional 30 days, and aspirin 100 mg was recommended throughout follow-up. For all patients, clinical follow-up was conducted by clinic visitation, or telephone interview. Angiographic follow-up with DSA was recommended at 6 months and 1 year after the procedure. Angiography follow-up (mean time 10.6 months) was obtained in 31 cases (88.6%). The technical feasibility of the procedure, procedure-related complications, angiographic results, clinical outcome and follow-up angiography were evaluated. Results: In every case, technical success was achieved. The degree of stenosis was reduced from 71.1% to 17.4% after balloon angioplasty and stenting. Immediate angiography demonstrated complete occlusion in 25 cases (71.4%), neck remnant in 7 cases (20.0%), and incomplete occlusion in 3 cases (8.6%). Procedure-related morbidity occurred in two

  17. Preliminary evaluation of the endovascular treatment of intracranial aneurysms with detachable coils in vigil patients Avaliação preliminar do tratamento endovascular de aneurismas intracranianos com espirais destacáveis em pacientes no estado de vigília

    OpenAIRE

    José Roberto Falco Fonseca; Nitamar Abdala; Dárcio Roberto Nalli; Marcos Hideki Idagawa; João de Deus da Costa Alves Jr; Márcio Chaves Pedro Marques; Henrique Carrete Jr; Roberto Gomes Nogueira; Jacob Szjenfeld

    2006-01-01

    Endovascular treatment of intracranial aneurysms with coil embolization became the most important therapeutic option with better morbidity and mortality rates and quality of life. Following immobility, patients are treated with general anaesthesia. OBJECTIVE: To test viability of endovascular treatment on wake patients. METHOD: Considering clinical symptoms, psychological characteristics and aneurysmal morphology, four patients with five intracranial aneurysms were selected. RESULTS: Four amo...

  18. Intracerebral malignant peripheral nerve sheath tumor in a child with neurofibromatosis Type 1 and middle cerebral artery aneurysm treated with endovascular coil embolization.

    Science.gov (United States)

    Ellis, Michael J; Cheshier, Samuel; Sharma, Sunjay; Armstrong, Derek; Hawkins, Cynthia; Bouffet, Eric; Rutka, James T; Taylor, Michael D

    2011-10-01

    Among the neoplastic conditions that affect patients with neurofibromatosis Type 1 (NF1) are malignant peripheral nerve sheath tumors (MPNSTs), which typically arise from peripheral nerves of the limbs, trunk, and lumbar and brachial plexuses. Ionizing radiation is an established risk factor for MPNST development, especially in susceptible patients such as those with NF1. Patients with NF1 are also at risk for intracranial aneurysms, which are increasingly being successfully managed with endovascular therapies. The authors describe the case of a 9-year-old, previously healthy girl who presented in extremis with a right frontal intracerebral hemorrhage resulting from a ruptured right middle cerebral artery (MCA) trifurcation aneurysm. Following urgent decompressive craniectomy, the patient underwent endovascular coil embolization of the MCA aneurysm without complication. Given her mother's history of NF1, the child underwent genetic testing, which disclosed signs positive for NF1. The patient recovered well, but follow-up MR imaging and MR angiography performed at 14 months demonstrated a large frontotemporal mass encasing the right MCA trifurcation. The patient underwent frontotemporal craniotomy and subtotal resection of the mass, which was histologically found to be an intracranial MPNST. The patient received chemotherapy and focal radiation therapy and remains alive at 6 months postresection. To the authors' knowledge, this represents the only known case of intracranial neoplasm arising in the region of an intracranial aneurysm repaired by endovascular coil embolization. While patients with NF1 represent a population with genetic susceptibility to radiation-induced tumors, the pathogenesis of intracerebral MPNSTs remains poorly understood. PMID:21961539

  19. Structural domains of vault proteins: a role for the coiled coil domain in vault assembly.

    Science.gov (United States)

    van Zon, Arend; Mossink, Marieke H; Schoester, Martijn; Scheffer, George L; Scheper, Rik J; Sonneveld, Pieter; Wiemer, Erik A C

    2002-03-01

    Vaults consist of multiple copies of three proteins (MVP, VPARP, and TEP1) and several untranslated RNAs. The function of vaults is unknown but the typical and evolutionary conserved structure indicates a role in intracellular transport. Although all vault components have been identified and characterized, not much is known about vault protein assembly. In this study we identified and analyzed structural domains involved in vault assembly with emphasis on protein-protein interactions. Using a yeast two-hybrid system, we demonstrate within MVP an intramolecular binding site and show that MVP molecules interact with each other via their coiled coil domain. We show that purified MVP is able to bind calcium, most likely at calcium-binding EF-hands. No interactions could be detected between TEP1 and other vault proteins. However, the N-terminal half of MVP binds to a specific domain in the C-terminus of VPARP. Furthermore, VPARP contains amino acid stretches mediating intramolecular binding. PMID:11855821

  20. Artefacts induced by coiled intracranial aneurysms on 3.0-Tesla versus 1.5-Tesla MR angiography—An in vivo and in vitro study

    International Nuclear Information System (INIS)

    Objective: To compare metal-induced artefacts from coiled intracranial aneurysms on 3.0-Tesla and 1.5-Tesla magnetic resonance angiography (MRA), since concerns persist on artefact enlargement at 3.0 Tesla. Materials and methods: We scanned 19 patients (mean age 53; 16 women) with 20 saccular aneurysms treated with coils only, at 1.5 and 3.0 Tesla according to standard clinical 3D TOF-MRA protocols containing a shorter echo-time but weaker read-out gradient at 3.0 Tesla in addition to intra-arterial digital subtraction angiography (IA-DSA). Per modality two neuro-radiologists assessed the occlusion status, measured residual flow, and indicated whether coil artefacts disturbed this assessment on MRA. We assessed relative risks for disturbance by coil artefacts, weighted kappa's for agreement on occlusion levels, and we compared remnant sizes. For artefact measurements, a coil model was created and scanned with the same protocols followed by 2D MR scans with variation of echo-time and read-out gradient strength. Results: Coil artefacts disturbed assessments less frequently at 3.0 Tesla than at 1.5 Tesla (RR: 0.3; 95%CI: 0.1–0.8). On 3.0-Tesla MRA, remnants were larger than on 1.5-Tesla MRA (difference: 0.7 mm; 95%CI: 0.3–1.1) and larger than on IA-DSA (difference: 1.0 mm; 95%CI: 0.6–1.5) with similar agreement on occlusion levels with IA-DSA for both field strengths (κ 0.53; 95%CI: 0.23–0.84 for 1.5-Tesla MRA and IA-DSA; κ 0.47; 95%CI: 0.19–0.76 for 3.0-Tesla MRA and IA-DSA). Coil model artefacts were smaller at 3.0 Tesla than at 1.5 Tesla. The echo-time influenced artefact size more than the read-out gradient. Conclusions: Artefacts were not larger, but smaller at 3.0 Tesla because a shorter echo-time at 3.0 Tesla negated artefact enlargement. Despite smaller artefacts and larger remnants at 3.0 Tesla, occlusion levels were similar for both field strengths

  1. Artefacts induced by coiled intracranial aneurysms on 3.0-Tesla versus 1.5-Tesla MR angiography—An in vivo and in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Schaafsma, Joanna D., E-mail: j.d.schaafsma@umcutrecht.nl [Department of Neurology, Rudolf Magnus Institute of Neuroscience, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Velthuis, Birgitta K., E-mail: b.k.velthuis@umcutrecht.nl [Imaging Division, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Vincken, Koen L., E-mail: koen@isi.uu.nl [Image Sciences Institute, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Kort, Gerard A.P. de, E-mail: g.a.p.dekort@umcutrecht.nl [Imaging Division, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Rinkel, Gabriel J.E., E-mail: g.j.e.rinkel@umcutrecht.nl [Department of Neurology, Rudolf Magnus Institute of Neuroscience, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Bartels, Lambertus W., E-mail: w.bartels@umcutrecht.nl [Image Sciences Institute, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands)

    2014-05-15

    Objective: To compare metal-induced artefacts from coiled intracranial aneurysms on 3.0-Tesla and 1.5-Tesla magnetic resonance angiography (MRA), since concerns persist on artefact enlargement at 3.0 Tesla. Materials and methods: We scanned 19 patients (mean age 53; 16 women) with 20 saccular aneurysms treated with coils only, at 1.5 and 3.0 Tesla according to standard clinical 3D TOF-MRA protocols containing a shorter echo-time but weaker read-out gradient at 3.0 Tesla in addition to intra-arterial digital subtraction angiography (IA-DSA). Per modality two neuro-radiologists assessed the occlusion status, measured residual flow, and indicated whether coil artefacts disturbed this assessment on MRA. We assessed relative risks for disturbance by coil artefacts, weighted kappa's for agreement on occlusion levels, and we compared remnant sizes. For artefact measurements, a coil model was created and scanned with the same protocols followed by 2D MR scans with variation of echo-time and read-out gradient strength. Results: Coil artefacts disturbed assessments less frequently at 3.0 Tesla than at 1.5 Tesla (RR: 0.3; 95%CI: 0.1–0.8). On 3.0-Tesla MRA, remnants were larger than on 1.5-Tesla MRA (difference: 0.7 mm; 95%CI: 0.3–1.1) and larger than on IA-DSA (difference: 1.0 mm; 95%CI: 0.6–1.5) with similar agreement on occlusion levels with IA-DSA for both field strengths (κ 0.53; 95%CI: 0.23–0.84 for 1.5-Tesla MRA and IA-DSA; κ 0.47; 95%CI: 0.19–0.76 for 3.0-Tesla MRA and IA-DSA). Coil model artefacts were smaller at 3.0 Tesla than at 1.5 Tesla. The echo-time influenced artefact size more than the read-out gradient. Conclusions: Artefacts were not larger, but smaller at 3.0 Tesla because a shorter echo-time at 3.0 Tesla negated artefact enlargement. Despite smaller artefacts and larger remnants at 3.0 Tesla, occlusion levels were similar for both field strengths.

  2. Possible dual role of decorin in abdominal aortic aneurysm.

    Directory of Open Access Journals (Sweden)

    Koshiro Ueda

    Full Text Available Abdominal aortic aneurysm (AAA is characterized by chronic inflammation, which leads to pathological remodeling of the extracellular matrix. Decorin, a small leucine-rich repeat proteoglycan, has been suggested to regulate inflammation and stabilize the extracellular matrix. Therefore, the present study investigated the role of decorin in the pathogenesis of AAA. Decorin was localized in the aortic adventitia under normal conditions in both mice and humans. AAA was induced in mice using CaCl2 treatment. Initially, decorin protein levels decreased, but as AAA progressed decorin levels increased in all layers. Local administration of exogenous decorin prevented the development of CaCl2-induced AAA. However, decorin was highly expressed in the degenerative lesions of human AAA walls, and this expression positively correlated with matrix metalloproteinase (MMP-9 expression. In cell culture experiments, the addition of decorin inhibited secretion of MMP-9 in vascular smooth muscle cells, but had the opposite effect in macrophages. The results suggest that decorin plays a dual role in AAA. Adventitial decorin in normal aorta may protect against the development of AAA, but macrophages expressing decorin in AAA walls may facilitate the progression of AAA by up-regulating MMP-9 secretion.

  3. The LVIS Jr. microstent to assist coil embolization of wide-neck intracranial aneurysms: clinical study to assess safety and efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Moehlenbruch, M.; Herweh, C.; Behrens, L.; Jestaedt, L.; Bendszus, M.; Pham, M. [University of Heidelberg Medical Center, Department of Neuroradiology, Heidelberg (Germany); Amiri, H.; Ringleb, P.A. [University of Heidelberg Medical Center, Department of Neurology, Heidelberg (Germany)

    2014-05-15

    This study was aimed to assess clinical safety and efficacy of the LVIS Jr. microstent in stent-assisted coil embolization of wide-neck intracranial aneurysms. IRB approved single-center interventional clinical study in 22 patients (10 females, 12 males, mean age 55, age range 33-74 years) for the endovascular treatment of wide-neck aneurysms. After obtaining informed consent, patients were included according to the following criteria: aneurysm fundus-to-neck ratio < 2 or neck diameter > 4 mm, and a parent vessel diameter of ≤3.5 mm. Primary end point for clinical safety was absence of death, absence of major or minor stroke, and absence of transient ischemic attack. Primary end point for treatment efficacy was complete angiographic occlusion according to the Raymond-Roy Occlusion Classification (RROC) immediately after the procedure and at follow-up after 3 and 6 months on magnetic resonance imaging (MRI). In 20/22 (91 %) of patients, the primary end point of safety was reached; in the two remaining patients, transient ischemic attack, but no permanent deficit was observed; in 16/22 (73 %), efficient occlusion (RROC1) was reached, and in 6/22 (27 %), a residual neck remained (RROC2). Single [seven with antegrade, two in crossover configuration, and four with ''first-balloon-then-stent'' (FBTS) technique] or double-stent (eight patients with Y configuration and one patient with X configuration) deployment was technically successful in all cases. Deployment of the LVIS Jr. microstent in various single- or double-stent configurations is safe and effective to assist the treatment of intracranial wide-neck aneurysms. (orig.)

  4. [The role of intraoperative flowmetry in surgery of cerebral aneurysms].

    Science.gov (United States)

    Shekhtman, O D; Éliava, Sh Sh; Shakhnovich, V A; Pilipenko, Iu V

    2011-01-01

    Aim of the study was to assess the capabilities of intraoperative ultrasonic flowmetry in cerebral aneurysm surgery for prevention and immediate correction of cerebral ischemia. Ultrasonic flowmeter (Model HT313/323, "ransonic Systems Inc.", USA) was used during surgery in patients with complicated, large and giant aneurysms for evaluation of cerebral blood flow in main arteries (internal carotid, anterior and middle cerebral) and their branches (branches of M2-M3 and A2 segments). The series included 20 adult patients (13 male and 7 female) operated in Burdenko Moscow Neurosurgery Institute during 2008-2011 years. Mean age was 47.4 +/- 8.6 years. Giant aneurysms (> 2.5 cm) were present in 12 (60%) patients, large (1.5-2.5 cm)--in 5 (25%). Aneurysms of internal carotid artery were found in 8 cases. 1 female patient was operated on giant aneurysm of anterior cerebral--anterior communicating artery. In 4 (20%) cases significant alterations of blood flow were registered after clipping (> 25% according to initial), the changes were not visible. This allowed to correct the position of clips. In 2 surgeries ('low' paraclinoid aneurysms) the collateral flow was sufficient during temporary clipping, this allowed trapping of aneurysms with good neurological outcome. In 3 cases flowmeter was used to evaluate blood flow after extracranial-intracranial bypass. Ultrasonic flowmetry is a simple, reproducible and safe technique for intraoperative assessment of blood flow. Despite visual sufficiency of arteries flowmetry allows detection of surgically significant alterations of blood flow after clipping. PMID:22066255

  5. Evaluation of post-procedure changes in aneurysmal lumen following detachable coil-placement using multi-planar reconstruction of high-field (3.0T) magnetic resonance angiography

    International Nuclear Information System (INIS)

    Placement of detachable coil(s) for intracranial aneurysms has become one of the standard methods of management. Although detailed analysis of post-procedure changes in aneurysmal lumen is essential, technical difficulties often limit such evaluation. Development of higher magnetic field systems is steadily widening clinical usage of magnetic resonance imaging (MRI) primarily due to its significantly higher signal to noise ratio. In this study, we evaluated a multi-planar reconstruction (MPR) technique of magnetic resonance angiography (MRA) on a 3.0T system in an attempt to develop a routine method of post-procedure evaluation following detachable coil placement. Eleven patients with an intracranial aneurysm following placement of a Guglielmi detachable coil (GDC) participated in the study. Time of flight (TOF) magnetic resonance angiography (MRA) was obtained immediately after, and up to two years after coil embolisation utilising a GE 3.0T system. Data was analysed using standard maximum intensity projection (MIP) as well as the MPR technique and the results were compared to conventional catheter angiography. The study demonstrated that, compared to MIP, MPR can provide further information of alteration in aneurysm lumen, especially in analysis of jet of blood flow; thrombus formation; neck remnant or re-filling of blood; location and shape of coils including compaction; coil protrusion into the parent artery. Combined MPR/MIP analysis of high-field MRA appears to be a powerful non-invasive method for evaluating GDC-treatment that can potentially replace conventional catheter angiography in many clinical situations. (author)

  6. Comparison of enterprise and neuroform stent-assisted coil embolization of distal internal carotid artery aneurysms: Midterm results from a single-center experience

    International Nuclear Information System (INIS)

    To compare the mid-term follow-up angiographic findings in distal internal carotid artery (ICA) aneurysms treated by stent-assisted coil embolization using the Enterprise or Neuroform stent. We included 68 patients with 70 aneurysms: 31 cases with Enterprise and 39 cases with Neuroform. Inclusion criteria were 1) location of the stent within the distal ICA, including the carotid siphon; 2) follow-up angiogram after > 6 months, and 3) single use of the stent for 1 parent artery. The patients' mean age was 54.9 years (16 male and 52 female). Mean follow-up duration was 9.1 months. At follow-up, there were intraluminal filling defects of the parent artery in 19.4% of the Enterprise group and no filling defect in the Neuroform group. There was no significant in-stent stenosis in either group. Straightening of the parent artery was seen in 35.5% of the Enterprise group and 20.5% of the Neuroform group. Two Enterprise cases showed delayed migration. The Enterprise showed statistically significant intraluminal filling defects of the parent artery compared with the Neuroform. The rates of significant in-stent stenosis and straightening of the parent artery were not significantly different between the Enterprise and the Neuroform groups.

  7. Validation of a Metal Artifact Reduction Algorithm Using 1D Linear Interpolation for Cone Beam CT after Endovascular Coiling Therapy for Cerebral Aneurysms.

    Science.gov (United States)

    Yasuda, Mitsuyoshi; Yoshikawa, Kohki; Kato, Kyoichi; Sai, Shogo; Sakiyama, Koshi; Kobayashi, Yoshifumi; Oosawa, Miwa; Sato, Hisaya; Matsumoto, Hiroaki; Nakazawa, Yasuo

    2014-12-01

    This study aimed to evaluate the effect of a metal artifact reduction (MAR) algorithm using 1D linear interpolation on cone-beam CT (CBCT). We performed phantom and clinical qualitative studies with and without MAR application using 1D linear interpolation. In the phantom study, the standard deviation (SD) was estimated from the images obtained from the water phantom in which a metal coil was placed at the center, and observed the changes in the SDs before and after MAR application. In the clinical qualitative study, the clinical images after endovascular treatment (EVT) for cerebral aneurysms were visually evaluated before and after MAR application. In the phantom study, the SDs after MAR application decreased by 56 to 35% compared with that before MAR application. In the clinical qualitative study, the artifacts from the metal coil decreased or increased depending on locations, and the contrasts of gray matter and white matter were attenuated when MAR was applied. In conclusion, the metal artifact decreases when MAR using 1D linear interpolation is applied to cerebral CBCT. However, another artifacts increase or soft tissue contrast is changed in some cases. MAR largely contributes to the reduction of streaking artifacts, whereas it may induce cerebral parenchyma at distant metal body or quality deterioration of the image not including the metal body. This should be taken into account in the diagnosis of secondary hemorrhage or infarction. PMID:25489899

  8. Aneurysm Complications

    Science.gov (United States)

    ... Brain Aneurysm Statistics and Facts Seeking Medical Attention Pediatric Aneurysms Brain Aneurysm Causes and Risk Factors Family History ... Brain Aneurysm Statistics and Facts Seeking Medical Attention Pediatric Aneurysms Brain Aneurysm Causes and Risk Factors Family History ...

  9. Multiple antiplatelet therapy contributes to the reversible high signal spots on diffusion-weighted imaging in elective coiling of unruptured cerebral aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Matsushige, Toshinori; Okazaki, Takahito; Shinagawa, Katsuhiro; Ichinose, Nobuhiko; Kurisu, Kaoru [Hiroshima University, Department of Neurosurgery, Graduate School of Biomedical and Health Sciences, Hiroshima (Japan); Kiura, Yoshihiro; Sakamoto, Shigeyuki [Hiroshima University Hospital, Department of Neurosurgery, Hiroshima (Japan); Takasu, Miyuki; Akiyama, Yuji [Hiroshima University Hospital, Department of Diagnostic Radiology, Hiroshima (Japan); Sugiyama, Kazuhiko [Hiroshima University Hospital, Department of Clinical Oncology and Neuro-oncology Program, Cancer Treatment Center, Hiroshima (Japan)

    2013-04-15

    Our aim was to systematically investigate radiographic characteristics and outcome of diffusion-weighted imaging (DWI) changes in the elective coiling of unruptured cerebral aneurysm with analyzing the correlation of antiplatelet therapy (APT). In a total of 34 consecutive patients with unruptured cerebral aneurysms initially treated by coiling without stent assist, 26 (76.5 %) had DWI changes with 91 high signal spots within 24-48 h after the procedure. We recorded DWI parameters (location, volume, mean, and minimum values of the apparent diffusion coefficient: expressed as ADC{sub AVE} and ADC{sub MIN}) for each lesion, and evaluated its radiographic outcome on conventional MRI at follow-up (interval, 58.4 {+-} 37.2 days) in the modes of APT. All patients with DWI high spots had no clinical symptoms. There was a strong correlation between ADC{sub AVE} and ADC{sub MIN} (r = 0.82, p < 0.0001). The mean ADC{sub AVE} and rADC{sub AVE} were 0.74 {+-} 0.14 x 10{sup -3} mm{sup 2}/s and 87 {+-} 10 %. DWI high spots were small with a mean volume of 0.13 {+-} 0.12 cm{sup 3}, ranging from 0.04 to 0.86 cm{sup 3}. A negative correlation was observed between the volume and values of ADC{sub AVE} (r = -0.48, p < 0.0001). The DWI volume was significantly larger in single APT than in multiple (0.15 {+-} 0.14 versus 0.10 {+-} 0.07 cm{sup 3}, p = 0.0091). The permanent signal change was more observed in single APT than in multiple (24.5 % versus 5.2 %, p = 0.02). DWI high spots after elective coiling were small without significant decrease of ADC, and do not correspond to brain infarction. Periprocedural use of multiple antiplatelet agents is expected to reduce the volume of thromboembolism and permanent tissue damages. (orig.)

  10. Cigarette Smoke and Inflammation: Role in Cerebral Aneurysm Formation and Rupture

    Directory of Open Access Journals (Sweden)

    Nohra Chalouhi

    2012-01-01

    Full Text Available Smoking is an established risk factor for subarachnoid hemorrhage yet the underlying mechanisms are largely unknown. Recent data has implicated a role of inflammation in the development of cerebral aneurysms. Inflammation accompanying cigarette smoke exposure may thus be a critical pathway underlying the development, progression, and rupture of cerebral aneurysms. Various constituents of the inflammatory response appear to be involved including adhesion molecules, cytokines, reactive oxygen species, leukocytes, matrix metalloproteinases, and vascular smooth muscle cells. Characterization of the molecular basis of the inflammatory response accompanying cigarette smoke exposure will provide a rational approach for future targeted therapy. In this paper, we review the current body of knowledge implicating cigarette smoke-induced inflammation in cerebral aneurysm formation/rupture and attempt to highlight important avenues for future investigation.

  11. The role of extracellular and intracellular proteolytic systems in aneurysms of the ascending aorta.

    Science.gov (United States)

    Werner, Isabella; Schack, Stephanie; Richter, Manfred; Stock, Ulrich A; Ahmad, Ali El-Sayed; Moritz, Anton; Beiras-Fernandez, Andres

    2016-05-01

    Aneurysms of the ascending aorta are an outstanding challenge to clinicians as they may persist asymptomatic until they present with dissection or rupture. Intensive research is performed to reveal the molecular mechanisms causing aneurysm formation. Calpains are ubiquitous non-lysosomal cysteine proteases which are classically activated by calcium signaling. The two major forms of the calpain-family are calpain-I and calpain-II. Calpastatin specifically inhibits the proteolytic activity of calpain-I and -II. Recently it has been demonstrated in aneurysm tissues from ascending aortas obtained from Marfan syndrome patients that calpain-II expression is increased and calpastatin expression is decreased. Thus, we were interested in the probable role of calpains in aneurysms of ascending aorta in non-Marfan patients. Therefore, ascending aortic samples of dilated and non-dilated aortas were analyzed according to their calpain-I, -II and calpastatin content as well as the expression levels of MMPs and elastin as well as the infiltration of inflammatory cells. We have found significant differences in calpain-I and calpastatin protein expression and serum levels in patients with aneurysm of the ascending aorta. Furthermore, MMP-1 and MMP-3 expression levels correlate with calpain-I protein levels. Due to our findings we conclude that calpain-1 seems to be related to fibrotic alteration in aortic aneurysm tissue in our experimental group. The change in calpain-1 modulates the structure of aortic tissue causing alteration in elastin structure, thus enabling macrophage infiltration and elevation of MMP levels. Circulating levels of calpain-1 may be used as a prognostic marker in the future if further correlation analyses are done. PMID:26582478

  12. Stent-assisted coil embolization for anterior communicating artery aneurysms%支架辅助弹簧圈栓塞治疗前交通动脉动脉瘤

    Institute of Scientific and Technical Information of China (English)

    刘佳强; 李真保; 方兴根

    2014-01-01

    前交通动脉(anterior communicating artery,ACoA)动脉瘤是最常见的颅内动脉瘤之一.宽颈ACoA动脉瘤的介入治疗仍然具有挑战性.几种颅内支架的相继问世以及多种支架技术的创新和发展,使得支架辅助弹簧圈栓塞逐渐成为治疗宽颈ACoA动脉瘤的首选技术之一.文章就ACoA动脉瘤的几种支架辅助弹簧圈栓塞技术进行了综述.%Anterior communicating artery (AcomA) aneurysm is one of the most common intracranial aneurysms.Interventional treatment of wide-neck AcomA aneurysms remains challenging.With the emergence of several intracranial stents and the innovation and development of a variety of stent technologies,stentassisted coiling (SAC) embolization has gradually become one of the preferable techniques for the treatment of wide-neck AcomA aneurysms.This article reviews several SAC embolization techniques of AcomA aneurysms.

  13. Cerebral aneurysms and inflammation

    Directory of Open Access Journals (Sweden)

    Toshihiro Yokoi

    2015-06-01

    Full Text Available Multiple inflammatory factors, playing a crucial role in cerebral aneurysm formation, have been identified. tumor necrosis factor-alpha (TNF-α has been revealed to have a close connection with several risk factors that affect aneurysm formation. Remarkable expression in aneurysm walls of mRNA for TNF-α has been observed in humans. Possible therapeutic interventions to reduce the formation of cerebral aneurysms may include the inhibition of mediators of inflammation.

  14. The Role of Bone Subtraction Computed Tomographic Angiography in Determining Intracranial Aneurysms in Non-Traumatic Subarachnoid Hemorrhage

    OpenAIRE

    Kayhan, Aysegul; Koc, Osman; Keskin, Suat; Keskin, Fatih

    2014-01-01

    Background: The presence of blood in the subarachnoid space is an acute pathology with a serious risk of death and complications. The most common etiology (approximately 80%) is intracranial aneurysm. Objectives: The aim of this study was to assess the role of bone subtracted computed tomographic angiography (BSCTA), a novel and noninvasive method for determining and characterizing intracranial aneurysms. Patients and Methods: Sixty consecutive patients with clinically suspected non-traumatic...

  15. Unusual Intracranial Stent Navigation through the Circle of Willis in a Patient with Recurrent Basilar Tip Aneurysm during Stent-Assisted Coiling: A Case Report

    OpenAIRE

    Puri, A.S.; Erdem, E.

    2009-01-01

    We describe a case of unusual Enterprise stent navigation through the Circle of Willis in a patient with a basilar tip aneurysm, left internal carotid artery (ICA) occlusion and previous right ICA stenting. Basilar tip aneurysms are known for their therapeutic challenges, especially when the posterior cerebral arteries (PCAs) are incorporated in the aneurysm neck. This becomes more technically demanding if the vertebral artery does not offer a route for stent navigation.

  16. Combined treatment for complex intracranial aneurysm

    Directory of Open Access Journals (Sweden)

    Chiriac A.

    2015-06-01

    Full Text Available Complex aneurysms often cannot be completely excluded by a single approaches. Today successful treatment of these lesions requires a combination between microsurgical and endovascular techniques. Planning of combined treatment require a very good understanding of aneurysm anatomy and a close collaboration between neurosurgeon and neuroendovascular interventionist. Endovascular coiling can usually be used as early treatment for a partially aneurysm occlusion including the ruptured area and followed by definitive clipping. On the other hand microsurgical clipping also can be used as first treatment for complex aneurysm neck reconstruction, allowing successful secondary placement of coils inside the remnant aneurysm sac

  17. Aneurysms of the ascending aorta and arch: the role of imaging in diagnosis and surgical management.

    Science.gov (United States)

    Bonnichsen, Crystal R; Sundt, Thoralf M; Anavekar, Nandan S; Foley, Thomas A; Morris, Michael F; Martinez, Matthew W; Williamson, Eric E; Glockner, James F; Araoz, Philip A

    2011-01-01

    Thoracic aortic aneurysms tend to be asymptomatic and were previously often diagnosed only after a complication such as dissection or rupture occurred. Better imaging techniques and an increase in the use of cross-sectional imaging has led to an increase in the diagnosis of aortic aneurysms, which has allowed for elective treatment prior to the development of a complication. The location, size and etiology of an aneurysm all impact the clinical outcomes and these factors are used to determine the appropriate timing of surgical replacement. Surgeons often rely on the information obtained from preoperative imaging to determine when to intervene and what type of procedure will be necessary, making it important for the radiologist to understand these issues in order to provide the necessary information. Postoperative imaging after surgical replacement of the aorta is also important, as there are some common findings that occur in this patient population that can impact how they are treated. The purpose of this article is to review the etiology and associated findings of aneurysms of the ascending aorta and arch, with a focus on how computed tomography angiography and magnetic resonance angiography findings are used to determine the appropriate timing for elective replacement and the type of surgical procedure, as well as the role of follow-up imaging. This will include a review of the most commonly performed types of surgical procedures, to provide an understanding of how the findings of preoperative imaging studies impact what the surgeon does in the operating room, as well as the expected findings of postoperative imaging studies. PMID:21166528

  18. Endovascular treatment of large and giant ophthalmic aneurysms with preservation of parent artery

    International Nuclear Information System (INIS)

    Objective: To evaluate the endovascular embolization treatment of large and giant ophthalmic aneurysms. Methods: Three aneurysms were embolized with coils only and 5 aneurysms were treated with stent placement together with subsequent coiling. Results: In the 3 aneurysms treated only with GDC, total embolization was achieved in 1 and partial embolization in 2. In the stent placement and coiling case, 4 aneurysms were densely packed and another one was partially packed. Conclusions: Combined stenting and coiling is effective and safe for the treatment of large and giant ophthalmic artery aneurysm with the preservation of parent artery

  19. The role of position a in determining the stability and oligomerization state of alpha-helical coiled coils: 20 amino acid stability coefficients in the hydrophobic core of proteins.

    OpenAIRE

    Wagschal, K.; Tripet, B; Lavigne, P; Mant, C.; Hodges, R. S.

    1999-01-01

    We describe here a systematic investigation into the role of position a in the hydrophobic core of a model coiled-coil protein in determining coiled-coil stability and oligomerization state. We employed a model coiled coil that allowed the formation of an extended three-stranded trimeric oligomerization state for some of the analogs; however, due to the presence of a Cys-Gly-Gly linker, unfolding occurred from the same two-stranded monomeric oligomerization state for all of the analogs. Denat...

  20. Neither Helix in the Coiled Coil Region of the Axle of F1-ATPase Plays a Significant Role in Torque Production

    OpenAIRE

    Hossain, Mohammad Delawar; Furuike, Shou; Maki, Yasushi; Adachi, Kengo; Suzuki, Toshiharu; Kohori, Ayako; Itoh, Hiroyasu; Yoshida, Masasuke; Kinosita, Kazuhiko

    2008-01-01

    F1-ATPase is an ATP-driven rotary molecular motor in which the central γ-subunit rotates inside the cylinder made of α 3 β 3 subunits. The amino and carboxy termini of the γ-subunit form the axle, an α-helical coiled coil that deeply penetrates the stator cylinder. We previously truncated the axle step by step, starting with the longer carboxy terminus and then cutting both termini at the same levels, resulting in a slower yet considerably powerful rotation. Here we examine the role of each h...

  1. Role of TGF beta signaling in Remodeling of Non-Coronary Artery Aneurysms in Kawasaki disease /

    OpenAIRE

    Lee, Aaron Ming

    2014-01-01

    Coronary artery aneurysms remain a life-threatening complication of Kawasaki disease (KD), the most common form of pediatric acquired heart disease in developed countries (1). Potentially life-threatening coronary artery aneurysms (CAA) develop in 25% of untreated children and 5% of children treated with high dose intravenous immunoglobulin during the acute phase of the self-limited vasculitis (2). Non-coronary artery aneurysms (NCAA) in extra-parenchymal, muscular arteries occur in a minorit...

  2. 3D-CT angiography in high-grade aneurysmal subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    We analyzed the role of 3D-CT angiography (3D-CTA) in the management of high-grade patients with severe subarachnoid hemorrhage (SAH) who were classified as Grade 5 by the Hunt-Kosnik grading system. From February 1995 to January 1997, 86 out of 92 patients with SAH were studied using 3D-CTA. There were 30 Grade 5 SAH patients (32.6%) including 5 patients who arrived in cardiopulmonary arrest (CPA). There were 13 men and 17 women, ranging in age from 46 to 89 years. Two-thirds were older than age 65 years. All patients underwent CT scan and were diagnosed with SAH. Excluding 5 CPA patients and one other patient, the remaining 24 patients successfully underwent 3D-CTA. As a result, ruptured aneurysms responsible for the SAH were clearly delineated in 19 patients (79.2%), and their anatomical relationships to the surrounding vessels were easily assessed. There were 8 patients with ICA aneurysms, 5 with MCA aneurysms, 2 with ACoA aneurysms, 2 with VA aneurysms, 1 with distal ACA aneurysm and 1 with distal PICA aneurysm. Intracranial vessels were not seen in 4 patients, 3 of whom had huge intracerebral hematomas associated with severe SAH. Proximal clipping was performed in a 46-years-old man with dissecting VA aneurysm. He later gained consciousness and became a surgical candidate. A 62-years-old woman underwent coil embolization for the large ICPC aneurysm after the level of her consciousness improved slightly following ventricular drainage. In conclusion, 3D-CTA can be performed safely and has a high detection rate of ruptured aneurysm even in patients with severe SAH. The results from these studies may gain further insight into epidemiology of SAH and ruptured aneurysms. (author)

  3. Coil Migration through a Neuroform 3 Stent during Endovascular Coiling. A Case Report.

    LENUS (Irish Health Repository)

    O'Hare, A

    2009-07-29

    Summary: A 43-year-old woman attended for stent assisted coiling. A Neuroform 30 x 4.5 mm stent had been successfully placed over the left periophthalmic aneurysm. During the coiling the first coil migrated through the crowns in the stent, lodging at the MCA bifurcation. We believe that the coil herniated through the overlying stent due to the carotid siphon curvature and the open cell design. Furthermore the distal markers of the stent impeded coil extraction with a MERCI device.

  4. Bare platinum coils vs. HydroCoil in the treatment of unruptured intracranial aneurysms—A single center randomized controlled study

    Energy Technology Data Exchange (ETDEWEB)

    Poncyljusz, Wojciech, E-mail: wponcyl@poczta.onet.pl [Departament of Interventional Radiology, Pomeranian Medical University, Neurointerventional Cath Lab MSW Hospital, Al. Powst. Wielkopolskich 72, 70-111 Szczecin (Poland); Zarzycki, Artur, E-mail: arturzarzycki@o2.pl [Department of Neurosurgery and Pediatric Neurosurgery, Pomeranian Medical University, Unii Lubelskiej 1, 71-242 Szczecin Poland (Poland); Zwarzany, Łukasz, E-mail: zwarzany@gmail.com [Departament of Interventional Radiology, Pomeranian Medical University, Neurointerventional Cath Lab MSW Hospital, Al. Powst. Wielkopolskich 72, 70-111 Szczecin (Poland); Burke, Thomas H., E-mail: tom.burke@microvention.com [Microvention–Terumo, Tustin, CA (United States)

    2015-02-15

    Highlights: • The use of HydroCoil tends to improve immediate angiographic outcome. • Less total number of coils is needed when using HydroCoil. • HydroCoil is equivocal to bare platinum coil. - Abstract: Purpose: The HydroCoil Embolic System (HES) was developed to improve aneurysm filling to provide superior occlusion efficacy, reduce retreatment rates and enhance long-term durability. We performed a randomized clinical trial to compare the effectiveness of bare platinum coils (BPC) vs. HES for unruptured intracranial aneurysms. Methods: Ninety-six patients underwent endovascular coiling of unruptured intracranial aneurysms. The aneurysms were randomized equally to receive BPC or HES. Immediate angiographic results, number of coils used and complications were evaluated and all cases had 12-month follow-up angiography. Results: Immediate angiographic results demonstrated that 84.0% of aneurysms treated with HES were completely occluded compared to 76.1% of aneurysms treated with BPC (p = 0.3310). The mean number of coils utilized to fill the aneurysm was significantly lower in the HES arm (5.04 vs. 6.93). Additional adjunctive techniques were performed in 51.1% of all cases. There were seven patients (7.3%) with postoperative complications during the study period. The coil type used during the treatment did not demonstrate any significant differences on the overall recurrence rate (HES – 18.0%, BPC – 17.4%, p = 0.9712). There was a statistically significant difference in the aneurysm size and the neck width between completely occluded aneurysms and aneurysms with residual flow in both immediate angiographic and mid-term follow-up. Conclusions: Overall, aneurysm size and neck width are the main risk factors associated with aneurysm recurrence. HES compared to BPC required less total number of coils to provide a denser aneurysm filling. However, there were equivocal results with both devices, at the mid-term angiographic follow-up.

  5. Bare platinum coils vs. HydroCoil in the treatment of unruptured intracranial aneurysms—A single center randomized controlled study

    International Nuclear Information System (INIS)

    Highlights: • The use of HydroCoil tends to improve immediate angiographic outcome. • Less total number of coils is needed when using HydroCoil. • HydroCoil is equivocal to bare platinum coil. - Abstract: Purpose: The HydroCoil Embolic System (HES) was developed to improve aneurysm filling to provide superior occlusion efficacy, reduce retreatment rates and enhance long-term durability. We performed a randomized clinical trial to compare the effectiveness of bare platinum coils (BPC) vs. HES for unruptured intracranial aneurysms. Methods: Ninety-six patients underwent endovascular coiling of unruptured intracranial aneurysms. The aneurysms were randomized equally to receive BPC or HES. Immediate angiographic results, number of coils used and complications were evaluated and all cases had 12-month follow-up angiography. Results: Immediate angiographic results demonstrated that 84.0% of aneurysms treated with HES were completely occluded compared to 76.1% of aneurysms treated with BPC (p = 0.3310). The mean number of coils utilized to fill the aneurysm was significantly lower in the HES arm (5.04 vs. 6.93). Additional adjunctive techniques were performed in 51.1% of all cases. There were seven patients (7.3%) with postoperative complications during the study period. The coil type used during the treatment did not demonstrate any significant differences on the overall recurrence rate (HES – 18.0%, BPC – 17.4%, p = 0.9712). There was a statistically significant difference in the aneurysm size and the neck width between completely occluded aneurysms and aneurysms with residual flow in both immediate angiographic and mid-term follow-up. Conclusions: Overall, aneurysm size and neck width are the main risk factors associated with aneurysm recurrence. HES compared to BPC required less total number of coils to provide a denser aneurysm filling. However, there were equivocal results with both devices, at the mid-term angiographic follow-up

  6. Endovascular treatment for pediatric intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Xianli; Jiang, Chuhan; Li, Youxiang; Yang, Xinjian; Wu, Zhongxue [Capital Medical University, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Beijing, Hebei (China)

    2009-11-15

    The purpose of this study is to report the characteristics and outcomes of pediatric patients with intracranial aneurysms. From 1998 to 2005, 25 pediatric patients (aged {<=}17 years) with intracranial aneurysm were treated at our institute. Eleven of 25 patients had subarachnoid hemorrhage. In ten patients, the aneurysm was an incidental finding. One patient presented with cranial nerves dysfunction and three with neurological deficits. The locations of the aneurysms were as follows: vertebral artery (VA; n = 9), middle cerebral artery (MCA; n = 5), posterior cerebral artery (PCA; n = 4), basilar artery (BA; n = 2), anterior communicating artery (n = 2), anterior cerebral artery (n = 2), and internal carotid artery (n = 1). Five patients were treated with selective embolization with coils. Sixteen patients were treated with parent vessel occlusion (PVO). Eight PVOs were performed with balloons and eight were performed with coils. One patient with a VA aneurysm was spontaneously thrombosed 4 days after the initial diagnostic angiogram. In three patients treated with stent alone or stent-assisted coiling, one with BA trunk aneurysm died. One aneurismal recurrence occurred and was retreated. At a mean follow-up duration of 23.5 months, 96% of patients had a Glasgow Outcome Scale score of 4 or 5. Pediatric intracranial aneurysms occur more commonly in male patients and have a predilection for the VA, PCA, and MCA. PVO is an effective and safe treatment for fusiform aneurysms. Basilar trunk fusiform aneurysms were difficult to treat and were associated with a high mortality rate. (orig.)

  7. Endovascular treatment for pediatric intracranial aneurysms

    International Nuclear Information System (INIS)

    The purpose of this study is to report the characteristics and outcomes of pediatric patients with intracranial aneurysms. From 1998 to 2005, 25 pediatric patients (aged ≤17 years) with intracranial aneurysm were treated at our institute. Eleven of 25 patients had subarachnoid hemorrhage. In ten patients, the aneurysm was an incidental finding. One patient presented with cranial nerves dysfunction and three with neurological deficits. The locations of the aneurysms were as follows: vertebral artery (VA; n = 9), middle cerebral artery (MCA; n = 5), posterior cerebral artery (PCA; n = 4), basilar artery (BA; n = 2), anterior communicating artery (n = 2), anterior cerebral artery (n = 2), and internal carotid artery (n = 1). Five patients were treated with selective embolization with coils. Sixteen patients were treated with parent vessel occlusion (PVO). Eight PVOs were performed with balloons and eight were performed with coils. One patient with a VA aneurysm was spontaneously thrombosed 4 days after the initial diagnostic angiogram. In three patients treated with stent alone or stent-assisted coiling, one with BA trunk aneurysm died. One aneurismal recurrence occurred and was retreated. At a mean follow-up duration of 23.5 months, 96% of patients had a Glasgow Outcome Scale score of 4 or 5. Pediatric intracranial aneurysms occur more commonly in male patients and have a predilection for the VA, PCA, and MCA. PVO is an effective and safe treatment for fusiform aneurysms. Basilar trunk fusiform aneurysms were difficult to treat and were associated with a high mortality rate. (orig.)

  8. Artificial Luminal Narrowing on Contrast-Enhanced Magnetic Resonance Angiograms on an Occasion of Stent-Assisted Coiling of Intracranial Aneurysm: In Vitro Comparison Using Two Different Stents with Variable Imaging Parameters

    Energy Technology Data Exchange (ETDEWEB)

    Seok, Jee Hyun; Choi, Hyun Seok; Jung, So Lyung; Ahn, Kook Jin; Kim, Myeong Jin; Shin, Yong Sam; Kim, Bum Soo [Seoul St. Mary' s Hospital, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2012-09-15

    Intracranial stenting for stent-assisted coiling of aneurysms requires adequate follow-up imaging. The aim of this in vitro study was to compare in-stent artificial luminal narrowing on contrast-enhanced MR angiograms (CE-MRA) when applying Neuroform and Enterprise stents for stent-assisted coiling. Two intracranial nitinol stents (Enterprise and Neuroform) were placed in silicon tubes and then imaged at 3 T and 1.5 T by the use of a T1-weighted three-dimensional spoiled gradient-echo sequence with minimal TR and TE. CE-MRAs were obtained by using different imaging planes, voxel sizes, and bandwidths, and with or without parallel imaging. Artificial lumen narrowing (ALN) was calculated and the results were compared. Lower magnetic field strength, axial plane perpendicular to axis of stent, and wider bandwidth resulted in a lower ALN on CE-MRA for both stents. Larger voxel size resulted in lower ALN for Neuroform stent. The parallel imaging acceleration factor did not affect ALN. The mean ALN was lower for Neuroform, but it was not significant by a paired t test. CE-MRA of the stented lumen of vascular phantom was partially impaired with ALN. Consequently, image plane orientation, magnetic field strength, bandwidth, and voxel size should be adjusted appropriately to reduce ALN.

  9. Artificial Luminal Narrowing on Contrast-Enhanced Magnetic Resonance Angiograms on an Occasion of Stent-Assisted Coiling of Intracranial Aneurysm: In Vitro Comparison Using Two Different Stents with Variable Imaging Parameters

    International Nuclear Information System (INIS)

    Intracranial stenting for stent-assisted coiling of aneurysms requires adequate follow-up imaging. The aim of this in vitro study was to compare in-stent artificial luminal narrowing on contrast-enhanced MR angiograms (CE-MRA) when applying Neuroform and Enterprise stents for stent-assisted coiling. Two intracranial nitinol stents (Enterprise and Neuroform) were placed in silicon tubes and then imaged at 3 T and 1.5 T by the use of a T1-weighted three-dimensional spoiled gradient-echo sequence with minimal TR and TE. CE-MRAs were obtained by using different imaging planes, voxel sizes, and bandwidths, and with or without parallel imaging. Artificial lumen narrowing (ALN) was calculated and the results were compared. Lower magnetic field strength, axial plane perpendicular to axis of stent, and wider bandwidth resulted in a lower ALN on CE-MRA for both stents. Larger voxel size resulted in lower ALN for Neuroform stent. The parallel imaging acceleration factor did not affect ALN. The mean ALN was lower for Neuroform, but it was not significant by a paired t test. CE-MRA of the stented lumen of vascular phantom was partially impaired with ALN. Consequently, image plane orientation, magnetic field strength, bandwidth, and voxel size should be adjusted appropriately to reduce ALN.

  10. The role of extra- and intracranial bypass in the treatment of complex aneurysms.

    Science.gov (United States)

    Cenzato, Marco; Bortolotti, Carlo

    2016-03-01

    The availability of flow diverters and new endovascular techniques has greatly reduced the need and indications for bypass surgery. Nevertheless, there are situations where a bypass is the best option for a complex cerebrovascular problem. Generally, typical indications are giant aneurysms with a wide neck and/or partially calcified aneurysms with main branches or perforating arteries arising directly from the sac or from the neck itself, or fusiform aneurysms, partially calcified aneurysms. In this paper we discuss the following issues as they apply to the modern use of bypass techniques. In case of fusiform aneurysms involving the proximal bifurcations of the media or the internal carotid artery combined and coordinated evaluations and efforts by a team which includes neurosurgeons and endovascular specialists is essential. Treatment with bypass alone may not be sufficient and the combination of one or more bypasses with an endovascular treatment of occlusion, partial aneurysm embolization or flow diversion may be the best strategy. Addressing complex and fusiform aneurysm surgery requires a problem solving attitude and in this lies both the challenging and the fun side of this surgery. PMID:26947783

  11. Role of 3-D Conventional Angiography In Evaluation of Intra Carnial Aneurysms

    Directory of Open Access Journals (Sweden)

    Ahmed M Bassiouny*, Maher M Arafa*, Sameh M Abdelwahab*,

    2013-04-01

    Full Text Available Introduction: intracranial aneurysms are pathological enlargement of the brain arteries that are most commonly located in the circle of Willis. Intracranial aneurysms are relatively common with a prevalence of approximately 4%. The real danger of aneurysms is subarachnoid hemorrhage. 3D digital subtraction angiography has become a critical imaging tool in neuroradiology allowing for the visualization of detailed cerebral vasculature prior to any intervention. Aim of the work: The aim of this work is to evaluate the diagnostic performance of 3D conventional angiography in the evaluation of intracranial aneurysms compared with the conventional cerebral angiography. Methods: The studied group included 20 patients (5 men and 15 women with subarachnoid hemorrhage or known to have cerebral aneurysms. All patients were subjected to conventional cerebral angiography and 3D cerebral angiography, using C-arm (Toshiba rotational technique.Results: 3D digital subtraction angiography is superior to conventional digital subtraction angiography in 100% of the cases 3D imaging revealed the proper aneurysmal shape, size, precise assessment of its neck and relation to the surrounding vessels. Conclusion: Three-dimensional DSA improves the detection and delineation of intracranial aneurysms

  12. Emergency Use of Stent and rtPA with Mechanical Cloth Defragmentation for a Thromboembolic Complication during GDC Coil Treatment of an Acutely Ruptured Basilar Tip Aneurysm.

    Science.gov (United States)

    Poncyljusz, W; Falkowski, A; Kojder, I; Sagan, L

    2006-11-30

    Thrombotic occlusion of both posterior cerebral arteries occurred during embolization of an acutely ruptured basilar tip aneurysm. Intracranial stenting and continuous superselective infusion of rtPA was administered combined with mechanical clot fragmentation to reestablish normal vessel flow. DSA disclosed that normal vessel patency was achieved within 30 min. There were no adverse events related to rtPA administration and the patient recovered from the embolization with minor neurologic deficit as present before the procedure. PMID:24351269

  13. Unruptured Brain Aneurysms

    Science.gov (United States)

    ... Brain Aneurysm Statistics and Facts Seeking Medical Attention Pediatric Aneurysms Brain Aneurysm Causes and Risk Factors Family History ... Brain Aneurysm Statistics and Facts Seeking Medical Attention Pediatric Aneurysms Brain Aneurysm Causes and Risk Factors Family History ...

  14. Brain Aneurysm: Treatment Options

    Science.gov (United States)

    ... Brain Aneurysm Statistics and Facts Seeking Medical Attention Pediatric Aneurysms Brain Aneurysm Causes and Risk Factors Family History ... Brain Aneurysm Statistics and Facts Seeking Medical Attention Pediatric Aneurysms Brain Aneurysm Causes and Risk Factors Family History ...

  15. [Treatment of aneurysmal subarachnoid hemorrhage].

    Science.gov (United States)

    Proust, François; Douvrin, Françoise; Gilles-Baray, Marie; Levêque, Sophie

    2007-01-01

    The incidence of subarachnoid hemorrhages is about 10.5/100,000 persons/year. Early obliteration of the aneurysmal sac is necessary to avoid rebleeding. The neurovascular staff meeting must decide the appropriate obliteration procedure for each patient. Intraoperative morbidity is 8% after endovascular coiling and 10% after microsurgical clipping. Endovascular coiling leads to complete obliteration of the aneurysm in 60% of patients and microsurgical clipping in 95%. Delayed ischemic deficits may be prevented by volemic expansion and calcium channel blockers. Hospitalization and general prophylaxis against deep venous thrombosis, pain and seizures are essential. Curative treatment is required against common complications such as intraparenchymatous hematoma, hydrocephalus, and delayed ischemic deficit. PMID:17296483

  16. Endovascular management of giant middle cerebral artery aneurysms

    OpenAIRE

    Huang, Lei; Cao, Wenjie; Ge, Liang; Lu, Gang; Wan, Jun; Zhang, Lei; Gu, Weijin; Zhang, Xiaolong; Geng, Daoying

    2015-01-01

    Background: This article reported the experience of endovascular treatment in giant middle cerebral artery (MCA) aneurysms with parent artery occlusion or stent-assisted coiling. Material and methods: Eleven consecutive patients with giant MCA aneurysms were included. The aneurysms predominantly involved the M1 segment in two cases, bifurcation in four cases, and M2 in five cases. Four M2 fusiform aneurysms were treated with parent artery sacrifice after balloon occlusion test. The seven unru...

  17. Basilar artery aneurysm with autonomic features: an interesting pathophysiological problem

    OpenAIRE

    Giffin, N; Goadsby, P

    2001-01-01

    Unruptured cerebral aneurysms often present with neuro-ophthalmological symptoms but ocular autonomic involvement from an aneurysm of the posterior circulation has not previously been reported. A patient is described with a basilar artery aneurysm presenting with headache and unilateral autonomic symptoms. After angiographic coiling of the aneurysm there was a near complete resolution of these features. The relevant anatomy and proposed mechanism of autonomic involvement of what may be ...

  18. Role of TGF-β signaling in remodeling of noncoronary artery aneurysms in kawasaki disease

    OpenAIRE

    Lee, AM; Shimizu, C.; Oharaseki, T; K. Takahashi; Daniels, LB; Kahn, A.; Adamson, R.; Dembitsky, W; Gordon, JB; Burns, JC

    2015-01-01

    © 2015 Society for Pediatric Pathology. Coronary artery aneurysms (CAA) remain an important complication of Kawasaki disease (KD), the most common form of pediatric acquired heart disease in developed countries. Potentially life-threatening CAA develop in 25% of untreated children and 5% of children treated with highdose intravenous immunoglobulin during the acute phase of the self-limited vasculitis. Noncoronary artery aneurysms (NCAA) in extraparenchymal, muscular arteries occur in aminorit...

  19. Pediatric intracranial aneurysms

    OpenAIRE

    Tripathy L; Singh S

    2009-01-01

    The incidence of subarachnoid haemorrhage from intracranial aneurysms in the paediatric age group is extremely rare. Interestingly, occurrence of vasospasm has been reported to be less in comparison to the adults. Both coiling and clipping have been advocated in selected cases. Because of the thinness of the wall of the arteries, utmost care should be taken while handling these arteries during surgery. The overall results of surgery in children have been reported to be better than their adult...

  20. Advances in endovascular aneurysm treatment: are we making a difference?

    International Nuclear Information System (INIS)

    Recent advancements in endovascular aneurysm repair, including bioactive and expansile coils and intracranial stents, hold promise for improved aneurysm occlusion rates. We report the immediate and midterm clinical and angiographic outcomes of a consecutive series of patients treated since the advent of these technologies. Clinical and radiological records of 134 patients with 142 aneurysms treated between 2001 and 2004 were retrospectively evaluated by an independent neurologist. Endovascular procedures were analyzed by an independent neuroradiologist blinded to all clinical information. Seventy-two ruptured and 60 un-ruptured saccular aneurysms, nine fusiform and one post-traumatic aneurysm were treated. Matrix coils were used in 53% of saccular aneurysms and HydroCoils in 13% of all aneurysms. Neuroform stents were deployed in 19% of aneurysms. Angiographic total or subtotal occlusion was achieved in 76% of cases and in 96% at last follow-up. Aneurysm recanalization was observed in 14% over a mean follow-up of 12 months, and 18% of aneurysms were retreated. Clinically relevant complications occurred in 6.0%, resulting in procedure-related morbidity of 0.6% and 0.6% mortality at 6 months. No aneurysm bled over a cumulative 1,347 months of observation. Newer embolization technologies can be exploited successfully even in more complex aneurysms with very low morbidity and mortality. (orig.)

  1. The Role of Computational Fluid Dynamics in the Management of Unruptured Intracranial Aneurysms: A Clinicians' View

    Directory of Open Access Journals (Sweden)

    Pankaj K. Singh

    2009-01-01

    Full Text Available Objective. The importance of hemodynamics in the etiopathogenesis of intracranial aneurysms (IAs is widely accepted. Computational fluid dynamics (CFD is being used increasingly for hemodynamic predictions. However, alogn with the continuing development and validation of these tools, it is imperative to collect the opinion of the clinicians. Methods. A workshop on CFD was conducted during the European Society of Minimally Invasive Neurological Therapy (ESMINT Teaching Course, Lisbon, Portugal. 36 delegates, mostly clinicians, performed supervised CFD analysis for an IA, using the @neuFuse software developed within the European project @neurIST. Feedback on the workshop was collected and analyzed. The performance was assessed on a scale of 1 to 4 and, compared with experts' performance. Results. Current dilemmas in the management of unruptured IAs remained the most important motivating factor to attend the workshop and majority of participants showed interest in participating in a multicentric trial. The participants achieved an average score of 2.52 (range 0–4 which was 63% (range 0–100% of an expert user. Conclusions. Although participants showed a manifest interest in CFD, there was a clear lack of awareness concerning the role of hemodynamics in the etiopathogenesis of IAs and the use of CFD in this context. More efforts therefore are required to enhance understanding of the clinicians in the subject.

  2. Aneurysmal wall enhancement and perianeurysmal edema after endovascular treatment of unruptured cerebral aneurysms.

    LENUS (Irish Health Repository)

    Su, I-Chang

    2014-06-01

    Perianeurysmal edema and aneurysm wall enhancement are previously described phenomenon after coil embolization attributed to inflammatory reaction. We aimed to demonstrate the prevalence and natural course of these phenomena in unruptured aneurysms after endovascular treatment and to identify factors that contributed to their development.

  3. Influencing factors of immediate angiographic results in intracranial aneurysms patients after endovascular treatment.

    Science.gov (United States)

    Chen, Jia-Xiang; Lai, Ling-Feng; Zheng, Kuang; Li, Guo-Xiong; He, Xu-Ying; Li, Liang-Ping; Duan, Chuan-Zhi

    2015-09-01

    The purpose of this study was to analyze influencing factors associated with immediate angiographic results in intracranial aneurysms patients after endovascular treatment (EVT), providing theoretical evidence and guidance for clinical treatment of intracranial aneurysms. Totally 529 patients met the inclusive criteria, consisting of 338 males and 191 females. Gender; age; history of hypertension, diabetes, and smoking; intracranial atherosclerosis; rupture status, size and location, features of aneurysmal neck, shapes; vasospasm; treatment modality; and degree of aneurysm occlusion were all carefully and completely recorded. All data were investigated in univariate and multivariate logistic regression model to determine whether they were correlated with the degree of aneurysm occlusion. According to aneurysm size, aneurysms were classified as micro-miniature, miniature, and large aneurysms. There were 451 narrow-neck aneurysms and 78 wide-neck aneurysms. Totally 417 were regular and 112 were irregular. And 125 were un-ruptured aneurysms; 404 were ruptured aneurysms. The modalities of treatment were as follows: embolization with coil (n = 415), stent-assisted coil embolization (n = 89), and balloon-assisted coil embolization (n = 25). Univariate analysis showed that aneurysm size, feature of aneurysm neck, shape, and rupture status might affect the immediate occlusion after EVT. Multivariate logistic regression analysis indicated that ruptured aneurysm, tiny aneurysm, and wide-neck aneurysm were independent influencing factors of complete occlusion of intracranial aneurysm. Aneurysm rupture status, size, feature of aneurysmal neck, and shape might be the independent influencing factors of immediate angiographic results in intracranial aneurysm patients after EVT. Un-ruptured, micro-miniature, narrow-neck, and regular-shaped aneurysms were more probable to be occluded completely. PMID:26100332

  4. Brain Aneurysm

    Science.gov (United States)

    A brain aneurysm is an abnormal bulge or "ballooning" in the wall of an artery in the brain. They are sometimes called berry aneurysms because they ... often the size of a small berry. Most brain aneurysms produce no symptoms until they become large, ...

  5. Endovascular treatment of an adolescent patient with ruptured intracranial aneurysm

    International Nuclear Information System (INIS)

    The occurrence of intracranial aneurysms in pediatric patients under 18 years of age is between 0,5-2% of all diagnosed aneurysms. We describe our experience with a patient of 10 years old with subarachnoid hemorrhage due to ruptured trilobular aneurysm on the top of the basilar artery, evidenced by CT angiography and DSA. Powered been consistently excluded from the bloodstream of two lobules of the aneurysm through coiling. Changed conditions of hemodynamics in aneurysmal sac fed to subsequent selftrombosing the third lobe of the aneurysm. Made control angiography after 10 months confirmed the good result of endovascular treatment and no neurological deficit. In conclusion it can be noted that in present conditions with a multidisciplinary approach endovascular treatment can be applied in this group of patients. (authors) Key words: SUBARACHNOID HEMORRHAGIA. CEREBRAL VESSEL ANEURYSM. BASILAR CEREBRAL ARTERY. COIL EMBOLIZATION

  6. Endovascular treatment of PICA aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Mukonoweshuro, W.; Laitt, R.D.; Hughes, D.G. [Radiology Dept., Greater Manchester Neurosciences Unit, Hope Hospital, Salford, Manchester (United Kingdom)

    2003-03-01

    Endovascular treatment of aneurysms of the posterior inferior cerebellar artery (PICA) avoids manipulation of the brainstem or lower cranial nerves and should therefore carry a lower risk of neurological morbidity than surgical clipping. We reviewed our experience of 23 patients with PICA aneurysms treated by endovascular occlusion with Guglielmi detachable coils and documented their long-term outcome on follow-up. We observed a 28 day procedure-related neurological morbidity of 13% (3/23 patients). One patient suffered permanent neurological complications. There were no procedure-related deaths. None of our patients suffered a re-bleed from their treated aneurysms. Our series shows endovascular treatment of ruptured PICA aneurysms to be safe and effective. (orig.)

  7. Endovascular reconstruction of aneurysms with a complex geometry.

    Science.gov (United States)

    Gupta, Vipul; Parthasarathy, Rajsrinivas; Jha, Ajaya Nand

    2016-01-01

    Conventional endovascular coiling remains the mainstay of treatment for most aneurysms; however, it may not be suitable for aneurysms with a complex geometry and there remains the risk of recanalization. Aneurysms with an unfavorable morphology are difficult to treat through both endovascular and surgical means. Progress in endovascular technology has allowed for the emergence of newer strategies to treat aneurysms with a complex geometry. Better packing density in wide-necked and large aneurysms can be achieved through the balloon remodeling technique. Similarly, a self-expanding stent cannot only act as a scaffold that helps to retain coils but also aids in diverting the blood flow away from the aneurysm sac. Lately, focus has shifted from endosaccular occlusion to endoluminal reconstruction; flow diverters are being increasingly used to treat aneurysms with an unfavorable geometry. However, there is no clear consensus on the best endovascular management strategy in certain subset of aneurysms - large and giant internal carotid aneurysms, blister aneurysms, and fusiform/dissecting aneurysms of the vertebrobasilar artery. We present a review of literature and discuss the current evidence for the various endovascular strategies to treat complex aneurysms. PMID:26954964

  8. The role of endorectal coil MRI in patient selection and treatment planning for prostate seed implants

    International Nuclear Information System (INIS)

    Purpose: To assess the role of endorectal coil magnetic resonance imaging (MRI) staging for patients undergoing seed implantation (SI) with or without external beam radiotherapy (EBRT). Methods and Materials: Between October 1994 and December 1998, 390 patients underwent prostate SI (98% Pd-103, 2% I-125). Seventy-six percent of patients had a prostate serum antigen (PSA) 20. Ten percent of patients had a Gleason score (GS) of 4-5, 54% had GS 6, 29% had GS 7, and 7% had GS ≥ 8. Monotherapy was employed in 46% of patients, and the remaining 54% received combined EBRT and SI. Three hundred twenty-seven were staged by high-resolution phased array pelvic coil, or in most cases, an endorectal coil MRI. The MRI findings were used to guide stage-appropriate treatment recommendations, and to assist in the preplanning and optimization of seed distributions. The criteria utilized to determine MRI-based stage were founded on the reported literature from the University of Pennsylvania. All MRI studies were reviewed by C.A., D.B., or W.H., who were unaware of clinical stage at the time of their review. The biopsy report was available to them as the only clinical correlate. Results: Of the 327 patients staged by MRI, 70% were upstaged from the digital rectal examination-based clinical stage; 26% of T1, T2 patients were upstaged to T3. Perineural invasion and the percentage of positive cores predicted for T3 MRI stage (p 3 intermediate-risk group patients treated by combined therapy with a previous study of T3 intermediate-risk group treated by radical prostatectomy (RP) at the University of Pennsylvania. Our 36-month PSA FFP was 94% compared with 21% for the previous study's RP patients. Conclusion: MRI is a valuable staging procedure for prostate cancer patients treated by SI. PSA FFP results appear to be improved by MRI staging. MRI T3 disease can be treated more effectively by SI + EBRT than by RP

  9. Insights on a Giant Aneurysm Treated Endovascularly.

    Science.gov (United States)

    Graziano, Francesca; Iacopino, Domenico Gerardo; Ulm, Arthur John

    2016-07-01

    Background Endovascular treatment with stent-assisted Guglielmi detachable coils is an accepted method for treating intracranial giant aneurysms that otherwise would require more invasive or destructive treatment or could not be treated at all. Nevertheless, there is a paucity of information concerning inner postcoiling aneurysmal changes in human subjects over the long term. We report a postmortem analysis of a patient with a giant aneurysm at the vertebrobasilar junction (VBJ) who was treated endovascularly and studied pathologically 24 months after treatment. Materials and Method The head was removed at autopsy and prefixed in a 10% neutral buffered formalin solution. The brain was gently removed from the skull base after cutting the intracranial nerves and vascular structures. The giant VBJ aneurysm and its relationship with the brainstem, cranial nerves, and vessels were captured photographically and analyzed. Afterward, under operating microscope guidance, the vertebrobasilar system with the aneurysm was gently and carefully detached from the brainstem and carefully analyzed. Results No complete fibrous obliteration of the aneurysm lumen could be detected in our case, and no endothelialization had taken place 24 months after treatment. Conclusions Our findings agree with those of previous similar reports. Coiling, in particular in large or giant aneurysms, may be burdened by the risk of coil compaction and recanalization, but it has the advantage of not affecting the flow in the perforating arteries. PMID:26296255

  10. Subarachnoid hemorrhage with blister aneurysms: Endovascular management

    Directory of Open Access Journals (Sweden)

    Swati Dayanand Chinchure

    2014-01-01

    Full Text Available Blister aneurysms of are rare lesions representing a real challenge for diagnosis and management. They typically show small size, hemispherical shape, fragile wall, broad neck, and are arising from non-branching sites of intracranial arteries. Materials and Methods: We retrospectively reviewed all aneurysms treated at our institution. Seventeen patients (6 male, 11 female with 17 blister aneurysms were identified (mean age 53.3, range 41-63 years. Clinical, procedural, angiographic data as well as follow up data were evaluated. Results: All patients presented with aneurysmal subarachnoid hemorrhage. Majority of the blister aneurysms were located in ICA while 1 was located at posterior cerebral artery, 1 at vertebral and 1 involving basilar artery. All patients were treated using single or overlapping stents and if possible additional coiling. There was no intra-operative rupture. Good outcome (mrs 0-2 was seen in 14 patients. Poor clinical outcome (mrs 3-5 was seen in 2 patients due to vasospasm induced ischemic deficits at discharge, both of them improved on follow up (mrs 1 on follow up. There were 3 mortalities, One patient died of rebleeding while other 2 died due to SAH induced complications. Follow-up angiography was available in 16 patients (one patient died before follow up angiogram and revealed complete or near complete aneurysm occlusion in 11, incomplete obliteration in 1 and no change in 2 cases. Two cases showed post-treatment angiographic aneurysm recurrence. Both cases were managed with repeat coiling and overlapping stent placement. Conclusion: Endovascular management using single/overlapping stent and if possible coil placement is technically safe and feasible in blister aneurysms. Overlapping stents lead to better aneurysm occlusion than a single stent. Blister aneurysm in dorso-medial ICA showed higher tendency of continued growth/recurrence, higher incidence of clinical vasospasm and in these cases early angiographic follow

  11. HydroCoils, occlusion rates, and outcomes: a large single-center study.

    LENUS (Irish Health Repository)

    O'Hare, A M

    2010-11-01

    The HydroCoil is an expansile hydrogel coil designed to produce a greater degree of volumetric packing within cerebral aneurysms when compared with bare platinum coils. This increased packing is, in turn, believed to decrease the risk of recurrence within aneurysms and hence the risk of their rupture in the long term. The aim of this work was to assess whether the use of HydroCoils and the proportion of HydroCoil used have any influence on the subsequent occlusion and recurrence rates of treated aneurysms.

  12. The role of gadolinium-enhanced MR imaging in the preoperative evaluation of inflammatory abdominal aortic aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Anbarasu, A.; McWilliams, R.G. [Department of Radiology, Royal Liverpool University Hospital, Prescot Street, Liverpool, L7 8XP (United Kingdom); Harris, P.L. [Department of Vascular Surgery, Royal Liverpool University Hospital, Prescot Street, Liverpool, L7 8XP (United Kingdom)

    2002-07-01

    Inflammatory abdominal aortic aneurysm is an uncommon variant of abdominal aortic aneurysms. Thorough preoperative imaging of the extent of the aneurysm and inflammation and the associated complications are crucial in the management of this condition. We report a case of inflammatory abdominal aortic aneurysm where, after the initial contrast-enhanced CT, gadolinium-enhanced MR imaging was used to define the true extent of the inflammation and differentiate inflammation from mural thrombus at the iliac extension of the aneurysm. The imaging appearances are presented and the impact of MR imaging on further surgical management options including endovascular repair are discussed. (orig.)

  13. The role of vascular remodeling and inflammation in the pathogenesis of intracranial aneurysms.

    Science.gov (United States)

    Penn, David L; Witte, Samantha R; Komotar, Ricardo J; Sander Connolly, E

    2014-01-01

    While the mechanisms triggering pathogenesis of intracranial aneurysms have not been fully elucidated, different mechanisms have been proposed ranging from hemodynamic mechanisms to genetic predispositions. One mechanism that has been thoroughly explored is the physiological and pathological vascular remodeling that occurs in conjunction with inflammatory reactions resulting in the initiation and progression of these lesions. Both hemodynamic stimuli and vascular inflammation can trigger a series of biochemical reactions resulting in vascular smooth muscle cell apoptosis and migration causing thinned, dilated areas of the cerebral vasculature. In addition, an imbalance between extracellular matrix remodeling proteins, such as matrix metalloproteinases and their inhibitors, can result in accelerated degradation of the internal elastic lamina and the adventitial layers, further weakening the vessel. While these processes occur under normal physiological conditions, situations that alter their balance such as inflammation caused by cigarette smoking or cocaine usage or hypoxia induced under chronic hypertensive conditions can alter the delicate balance of these reactions potentiating pathological remodeling and aneurysm development. The present study represents a thorough literature review of the vascular remodeling and inflammatory components to aneurysmal pathogenesis. PMID:24120708

  14. Combined Surgical and Endovascular Management of a Giant Fusiform PCA Aneurysm in a Pediatric Patient: A Case Report

    OpenAIRE

    Shin, S.H.; Choi, I. S.; THOMAS, K.; David, C.A.

    2013-01-01

    Treatment of intracranial giant aneurysms presents is challenging. In the case of pediatric giant aneurysm, more challenges arise. We describe our experience with a 17-year-old pediatric patient who presented with severe headache. She was diagnosed as having a giant fusiform aneurysm at the right P1-P2-Pcom junction. The aneurysm was treated with superficial temporal artery-posterior cerebral artery bypass and subsequent coil embolization of the aneurysm with parent artery occlusion. The pati...

  15. Advances in the imaging of cerebral aneurysm inflammation

    Directory of Open Access Journals (Sweden)

    Michael R Levitt

    2015-06-01

    Full Text Available Cerebral aneurysm formation, growth and rupture are thought to be the result of a complex interaction between cerebrovascular hemodynamics and pathobiology. Recently, new evidence has emerged regarding the role of inflammation in the walls of cerebral aneurysms. Noninvasive methods to characterize the degree of inflammation in aneurysms could enable clinicians to estimate the risk of future aneurysm growth and rupture, influencing treatment. This review examines emerging techniques of imaging inflammatory biomarkers in cerebral aneurysms.

  16. Essential role of coiled-coils for aggregation and activity of Q/N-rich prions and polyQ proteins

    OpenAIRE

    Fiumara, Ferdinando; Fioriti, Luana; Kandel, Eric R.; Hendrickson, Wayne A.

    2010-01-01

    The functional switch of glutamine/asparagine (Q/N)-rich prions and the neurotoxicity of polyQ-expanded proteins involve complex aggregation-prone structural transitions, commonly presumed to be forming β-sheets. By analyzing sequences of interaction partners of these proteins, we discovered a recurrent presence of coiled-coil domains both in the partners and in segments that flank or overlap Q/N-rich and polyQ domains. Since coiled-coils can mediate protein interactions and multimerization, ...

  17. Endovascular therapeutic strategies in ruptured intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Machi, Paolo, E-mail: paolo.machi@gmail.com [CHRU Montpellier, Service de Neurorradiologie, Hopital Gui de Chauliac, 80 Avenue Augustin Fliche, 34295 Montpellier Cedex 5 (France); Lobotesis, Kyriakos, E-mail: kyriakos@lobotesis.co.uk [CHRU Montpellier, Service de Neurorradiologie, Hopital Gui de Chauliac, 80 Avenue Augustin Fliche, 34295 Montpellier Cedex 5 (France); Vendrell, Jean Francoise, E-mail: jfvendrell@yahoo.fr [CHRU Montpellier, Service de Neurorradiologie, Hopital Gui de Chauliac, 80 Avenue Augustin Fliche, 34295 Montpellier Cedex 5 (France); Riquelme, Carlos, E-mail: riquelme.carlos@neuf.fr [CHRU Montpellier, Service de Neurorradiologie, Hopital Gui de Chauliac, 80 Avenue Augustin Fliche, 34295 Montpellier Cedex 5 (France); Eker, Omer, E-mail: eker_omer@yahoo.fr [CHRU Montpellier, Service de Neurorradiologie, Hopital Gui de Chauliac, 80 Avenue Augustin Fliche, 34295 Montpellier Cedex 5 (France); Costalat, Vincent, E-mail: vincentcost@hotmail.com [CHRU Montpellier, Service de Neurorradiologie, Hopital Gui de Chauliac, 80 Avenue Augustin Fliche, 34295 Montpellier Cedex 5 (France); Bonafe, Alain, E-mail: bonafeh@aol.com [CHRU Montpellier, Service de Neurorradiologie, Hopital Gui de Chauliac, 80 Avenue Augustin Fliche, 34295 Montpellier Cedex 5 (France)

    2013-10-01

    The aim of the present study was to evaluate endovascular techniques used currently which were not available at the time of ISAT inclusion period, such as balloon remodelling and flow-divertion, in order to assess whether these new technologies have improved the endovascular approach outcomes. We present a review of articles, published in major journals, with the aim to evaluate the efficacy and the safety of coiling with balloon remodelling for the treatment of ruptured aneurysms in comparison to coiling performed without such coadjutant techniques. Furthermore, we reviewed publications reporting on the treatment of ruptured aneurysms in the acute phase with the one of the most recent technologies available nowadays: the flow diverting stent. Looking at the recent literature the results regarding ruptured aneurysms treated with balloon assisted coiling (BAC) have shown an improvement in terms of anatomical results and morbi-mortality rates. Case series of ruptured middle cerebral artery (MCA) aneurysms treated by EVT report results similar to those obtained by surgical clipping. Several articles recently report encouraging results in treating ruptured dissecting and blister aneurysms with flow diverters. Questions regarding the best treatment available for ruptured aneurysms are yet to be answered. Hence there is a need for a subsequent trial aiming to answer these unresolved issues.

  18. Individualized management for intracranial vertebral artery dissecting aneurysms

    Directory of Open Access Journals (Sweden)

    SHANG Yan-guo

    2012-02-01

    Full Text Available Objective To discuss the individualized management strategy for intracranial vertebral artery dissecting aneurysms. Methods Eighteen patients with intracranial vertebral artery dissecting aneurysms were treated with different surgical methods. Results Eighteen patients underwent different surgical treatment. Five patients underwent complete occlusion of the aneurysm and parent artery by coiling, 5 were treated by stent -assisted coiling (3 densely packed coiling and 2 non-densely packed coiling, 4 underwent stent-only therapy and 3 of them presented hemodynamic improvement after surgery, 3 were treated by direct surgical clipping, and 1 underwent occipital artery-posterior inferior cerebellar artery bypass. Two aneurysms ruptured immaturely, in which one patient died on the third day after operation and one patient occurred moderate disablity. Only 1 patient who underwent complete occlusion of aneurysm and parent artery presented temporarily ischemic symptoms. No adverse effects were seen in other patients. Seventeen patients were followed up for 1 month to 3 years, and all the aneurysms were stable. Conclusion There are many kinds of therapeutic methods for intracranial vertebral artery dissecting aneurysms. The patients should be treated according to several factors such as the clinical manifestations, aneurysm configuration, and relationship with the posterior inferior cerebellar artery. The treatment should be individualized.

  19. Combined Endovascular and Microsurgical Management of Complex Cerebral Aneurysms

    Directory of Open Access Journals (Sweden)

    Omar eChoudhri

    2013-08-01

    Full Text Available Cerebral aneurysms are associated with a 50% mortality rate after rupture and patients can suffer significant morbidity during subsequent treatment. Neurosurgical management of both ruptured and unruptured aneurysms has evolved over the years. The historical practice of using microsurgical clipping to treat aneurysms has benefitted in the last two decades from tremendous improvement in endovascular technology. Microsurgery and endovascular therapies are often viewed as competing treatments but it is important to recognize their individual limitations. Some aneurysms are considered complex, due to several factors such as aneurysm anatomy and a patient’s clinical condition. A complex aneurysm often cannot be completely excluded with a single approach and its successful treatment requires a combination of microsurgical and endovascular techniques. Planning such an approach relies on understanding aneurysm anatomy and thus should routinely include 3D angiographic imaging. In patients with ruptured aneurysms, endovascular coiling is a well-tolerated early treatment and residual aneurysms can be treated with intervals of definitive clipping. Microsurgical clipping also can be used to reconstruct the neck of a complex aneurysm, allowing successful placement of coils across a narrow neck. Endovascular techniques are assisted by balloons, which can be used in coiling and testing parent vessel occlusion before sacrifice. In some cases microsurgical bypasses can provide alternate flow for planned vessel sacrifice. We present current paradigms for combining endovascular and microsurgical approaches to treat complex aneurysms and share our experience in 67 such cases. A dual microsurgical–endovascular approach addresses the challenge of intracranial aneurysms. This combination can be performed safely and produces excellent rates of aneurysm obliteration. Hybrid angiographic operating-room suites can foster seamless and efficient complementary application

  20. The Role of Quench-back in the Passive Quench Protection of Long Solenoids with Coil Sub-division

    Energy Technology Data Exchange (ETDEWEB)

    Green, Michael A.; Guo, XingLong; Wang, Li; Pan, Heng; Wu, Hong

    2009-10-19

    This paper describes how a passive quench protection system can be applied to long superconducting solenoid magnets. When a solenoid coil is long compared to its thickness, the magnet quench process will be dominated by the time needed for uench propagation along the magnet length. Quench-back will permit a long magnet to quench more rapidly in a passive way. Quenchback from a conductive (low resistivity) mandrel is essential for spreading the quench along the length of a magnet. The andrel must be inductively coupled to the magnet circuit that is being quenched. Current induced in the mandrel by di/dt in the magnet produces heat in the mandrel, which in turn causes the superconducting coil wound on the mandrel to quench. Sub-divisions often employed to reduce the voltages to ground within the coil. This paper explores when it is possible for quench-back to be employed for passive quench protection. The role of sub-division of the coil is discussed for long magnets.

  1. Stent-jail technique in endovascular treatment of wide neck aneurysm - a case report

    International Nuclear Information System (INIS)

    We present a case report which it's applied by a stent-assisted embolization techniques of intracranial aneurysms with wide necks. Here we describe methodology as known in the art such as stent-jail technique of embolization, presenting in a patient with AVM, combined with ruptured aneurysms with a wide neck. Located at the tip of the basilar artery. The methodology consists of the aneurysmal catheterization with microcatheter, before application of the stent across the wide neck of the aneurysm. After the stent deployment, we embolise the aneurysm by platinum coils and microcatheter is wedged between the stent and the vessel wall. After we fill the aneurysm dome, we pull out the microcatheter and the stent is detached. This method allows elimination of the possibility of herniation of coils, or their migration in free arterial lumen with subsequent complications. Key words: INTRACRANIAL ANEURYSM. EMBOLIZATION OF ANEURYSM. JAIL TECHNIQUE

  2. Brain aneurysm repair

    Science.gov (United States)

    ... aneurysm repair; Dissecting aneurysm repair; Endovascular aneurysm repair - brain; Subarachnoid hemorrhage - aneurysm ... Your scalp, skull, and the coverings of the brain are opened. A metal clip is placed at ...

  3. Brain Aneurysm Statistics and Facts

    Science.gov (United States)

    ... Brain Aneurysm Statistics and Facts Seeking Medical Attention Pediatric Aneurysms Brain Aneurysm Causes and Risk Factors Family History ... Brain Aneurysm Statistics and Facts Seeking Medical Attention Pediatric Aneurysms Brain Aneurysm Causes and Risk Factors Family History ...

  4. Spontaneous thrombosis of basilar tip aneurysm: Role of neuroimaging and follow-up with review of literature

    OpenAIRE

    Anand Alurkar; Karanam, Lakshmi S P; Sagar Oak

    2012-01-01

    The incidence of pediatric aneurysms is rare compared to that of the adults. The natural history and the course of these aneurysms were not well understood. We present a rare case of spontaneously thrombosed basillar tip nongiant aneurysm in a 9-year-old male child who presented with symptoms of mass effect and subsequently followed up by imaging over a period of 1 year.

  5. Basilar Artery Aneurysm at a Persistent Trigeminal Artery Junction

    Science.gov (United States)

    Aguiar, G.B.; Conti, M.L.M.; Veiga, J.C.E.; Jory, M.; Souza, R.B.

    2011-01-01

    Summary The trigeminal artery is an anastomosis between the embryonic precursors of the vertebrobasilar and carotid systems, and may persist into adult life. The association of the persistent primitive trigeminal artery (PTA) with cerebral aneurysm is well documented in the literature and, in general, aneurysms are located in the anterior circulation. We describe a patient who presented with a panencephalic Fisher III subarachnoid hemorrhage due to rupture of an intracranial aneurysm. Digital arteriography showed a saccular aneurysm in the middle third of the basilar artery, adjacent to the junction with a persistent trigeminal artery. She was submitted to endovascular treatment with embolization of the basilar artery aneurysm with coils. Aneurysms at the PTA junction with the basilar artery are rare. This paper describes a case of PTA associated with an aneurysm in the basilar artery at PTA junction and briefly reviews the literature. PMID:22005697

  6. Spontaneous thrombosis of a recurrent clipped intracranial aneurysm.

    Science.gov (United States)

    Hassan, F; Taschner, C-A; Thines, L; Lejeune, J-P; Pruvo, J-P; Leclerc, X

    2009-06-01

    Spontaneous thrombosis of an intracranial aneurysm is a rare event. It is predominantly observed with aneurysms that are large and have relatively narrow necks. We report here a case of a 48-year-old woman presenting with subarachnoid hemorrhage (SAH) due to rupture of a 2-mm aneurysm of the anterior cerebral artery treated by microsurgical clipping. Six months after treatment of the aneurysm, the patient presented with severe headache. SAH was excluded, but computed tomographic angiography (CTA) revealed the recurrence of a large aneurysm (7 mm) that was confirmed by cerebral angiography (DSA). Endovascular treatment was scheduled for several days later, but DSA also revealed spontaneous occlusion of the recurrent aneurysm. On the control CTA performed one week later, the recurrent aneurysm had again reappeared, again confirmed by DSA, and was subsequently treated by coil embolization. PMID:19144409

  7. Giant aneurysm in 6 years old child - case report

    International Nuclear Information System (INIS)

    Intracranial saccular aneurysms rare in childhood is. Even among the reported series of childhood aneurysms, it is unusual to find their occurrence in children less than 7 years old. The pathogenesis of these lesions is also a matter of debate and speculations. The peak age of incidence of juvenile cerebral aneurysms appear to be 12 years, occurrence below the age of 7 being rarity. We show a case of 6 years old boy with giant aneurysm. found because of episodes of headache and vomiting. Discussion of pathogenesis for the rare pathology. After discussion of multidisciplinary team, of neuroradiologist and neurosurgeons was decided to be perform endovascular embolization, because of the better outcome for the patient. We performed endovascular treatment of the aneurysm with achieving total embolization. The patient recovery completely, and after 4 days went home. (authors) Key words: GIANT ANEURYSM. SACCULAR ANEURYSM. EMBOLIZATION. STENT ASSISTED COILING

  8. Management of Agitation Following Aneurysmal Subarachnoid Hemorrhage: Is There a Role for Beta-Blockers?

    Directory of Open Access Journals (Sweden)

    Fayaz Ibrahim

    2012-01-01

    Full Text Available Introduction. Stroke is a leading cause of mortality and morbidity in the United States. About 20% of the stroke is hemorrhagic and about 50% of these is due to aneurysmal subarachnoid hemorrhage. A troublesome neuropsychiatric complication of subarachnoid hemorrhage is agitation/aggression. Case Presentation. A 45-year-old man with no prior psychiatric history, sustained subarachnoid hemorrhage. After initial stabilization for 2 days, he underwent craniotomy and clipping of anterior cerebral communicating artery aneurysm. Treatment was continued with labetalol, nimodipine, and levetiracetam. Beginning postoperative day 4, patient developed episodes of confusion and agitation/aggression. Switching of Levetiracetam to valproate did not show any improvement. Psychiatry team tried to manage him with intense nursing intervention and different medications like olanzapine, valproate, lorazepam, and haloperidol. However, patient continued to be agitated and aggressive. Switching from labetalol to metoprolol resulted in dramatic improvement within 3 days. Discussion. Antipsychotics and benzodiazepines are often not sufficiently effective in the control of agitation/aggression in patients with traumatic brain injury and similar conditions. Our case report and the literature review including a cochrane review suggests that beta-blockers may be helpful in this situation.

  9. Aneurysms: thoracic aortic aneurysms.

    Science.gov (United States)

    Chun, Kevin C; Lee, Eugene S

    2015-04-01

    Thoracic aortic aneurysms (TAAs) have many possible etiologies, including congenital heart defects (eg, bicuspid aortic valves, coarctation of the aorta), inherited connective tissue disorders (eg, Marfan, Ehlers-Danlos, Loeys-Dietz syndromes), and degenerative conditions (eg, medial necrosis, atherosclerosis of the aortic wall). Symptoms of rupture include a severe tearing pain in the chest, back, or neck, sometimes associated with cardiovascular collapse. Before rupture, TAAs may exert pressure on other thoracic structures, leading to a variety of symptoms. However, most TAAs are asymptomatic and are found incidentally during imaging for other conditions. Diagnosis is confirmed with computed tomography scan or echocardiography. Asymptomatic TAAs should be monitored with imaging at specified intervals and patients referred for repair if the TAAs are enlarging rapidly (greater than 0.5 cm in diameter over 6 months for heritable etiologies; greater than 0.5 cm over 1 year for degenerative etiologies) or reach a critical aortic diameter threshold for elective surgery (5.5 cm for TAAs due to degenerative etiologies, 5.0 cm when associated with inherited syndromes). Open surgery is used most often to treat asymptomatic TAAs in the ascending aorta and aortic arch. Asymptomatic TAAs in the descending aorta often are treated medically with aggressive blood pressure control, though recent data suggest that endovascular procedures may result in better long-term survival rates. PMID:25860136

  10. Stroke Secondary to Aseptic Meningitis After Endovascular Treatment of a Giant Aneurysm with Parent Artery Occlusion

    International Nuclear Information System (INIS)

    Aseptic meningitis related to hydrogel-coated coils is a known complication, but it is extremely rare after platinum bare coil aseptic meningitis. Here we report the development of aseptic meningitis causing brain stem and cerebellar infarct in a patient with a giant aneurysm treated with bare platinum coils. We conclude that aneurysm size is an important factor affecting the occurrence of aseptic meningitis associated with stroke.

  11. Thoracic aortic aneurysm and dissection.

    Science.gov (United States)

    Goldfinger, Judith Z; Halperin, Jonathan L; Marin, Michael L; Stewart, Allan S; Eagle, Kim A; Fuster, Valentin

    2014-10-21

    Aortic dissection is the most devastating complication of thoracic aortic disease. In the more than 250 years since thoracic aortic dissection was first described, much has been learned about diseases of the thoracic aorta. In this review, we describe normal thoracic aortic size; risk factors for dissection, including genetic and inflammatory conditions; the underpinnings of genetic diseases associated with aneurysm and dissection, including Marfan syndrome and the role of transforming growth factor beta signaling; data on the role for medical therapies in aneurysmal disease, including beta-blockers, angiotensin receptor blockers, and angiotensin-converting enzyme inhibitors; prophylactic surgery for aneurysm; surgical techniques for the aortic root; and surgical and endovascular management of aneurysm and dissection for different aortic segments. PMID:25323262

  12. Meiosis specific coiled-coil proteins in Shizosaccharomyces pombe

    Directory of Open Access Journals (Sweden)

    Okuzaki Daisuke

    2007-05-01

    Full Text Available Abstract Many meiosis-specific proteins in Schizosaccharomyces pombe contain coiled-coil motifs which play essential roles for meiotic progression. For example, the coiled-coil motifs present in Meu13 and Mcp7 are required for their function as a putative recombinase cofactor complex during meiotic recombination. Mcp6/Hrs1 and Mcp5/Num1 control horsetail chromosome movement by astral microtubule organization and anchoring dynein respectively. Dhc1 and Ssm4 are also required for horsetail chromosome movement. It is clear from these examples that the coiled-coil motif in these proteins plays an important role during the progression of cells through meiosis. However, there are still many unanswered questions on how these proteins operate. In this paper, we briefly review recent studies on the meiotic coiled-coil proteins in Sz. pombe.

  13. Endovascular treatment of the posterior inferior cerebellar artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Bradac, G.B.; Bergui, M. [Neuroradiology, Univ. di Torino, Turin (Italy)

    2004-12-01

    Aneurysms may arise at various locations along the course of the posterior inferior cerebellar artery. Brainstem and cranial nerves manipulation make the surgical approach to proximal aneurysms difficult, while the occlusion of the parent vessel is sometimes unavoidable in peripheral aneurysms. Endovascular treatment can be a good alternative, but also with this approach the location of the aneurysm is critical. If occlusion of the parent vessel is planned, anatomical variations and vascular territories of the brainstem should be considered. We report our experience with 18 consecutive aneurysms (12 proximal, 6 peripheral) treated by coils. Complete occlusion was achieved in 14 patients and subtotal in 4. In three patients the parent vessel had to be sacrificed. During treatment two perforations occurred; aneurysms were completely occluded without clinical consequences. Two small asymptomatic cerebellar infarctions were seen on postoperative computed tomography. Clinical outcome was good in 16 patients. (orig.)

  14. Endovascular treatment of ruptured, tiny and wide-necked intracranial aneurysms by Semi-jailing stent-assisted coiling technique%支架半释放技术辅助弹簧圈栓塞治疗破裂的颅内微小动脉瘤

    Institute of Scientific and Technical Information of China (English)

    黄清海; 聂景浩; 吕楠; 邹超; 许奕; 洪波; 赵文元; 刘建民

    2013-01-01

    目的 探讨支架半释放技术辅助弹簧圈栓塞破裂颅内微小宽颈动脉瘤的可行性、有效性和安全性.方法 2007年1月至2011年8月采用支架半释放技术辅助弹簧圈栓塞治疗破裂颅内微小宽颈动脉瘤37例.结果 所有患者均成功通过支架半释放技术辅助弹簧圈栓塞治疗.术后即刻造影结果显示,Raymond分级Ⅰ级26例,Ⅱ级8例,Ⅲ级3例.28例患者影像学随访3~24个月,平均10.4个月,未发现支架内再狭窄或复发.36例患者临床随访9~48个月,平均21.3个月,无再出血或死亡病例.结论 支架半释放技术辅助弹簧圈栓塞治疗破裂颅内微小宽颈动脉瘤是安全、可行的.该技术通过增加瘤颈周围的填塞密度和改善血液动力学进一步提高长期疗效.%Objective To evaluate the feasibility,effectiveness,and safety of the embolization of the ruptured,tiny and wide-necked intracranial aneurysms by semi-jailing stent-assisted coiling technique.Method Thirty-seven tiny,wide-necked and ruptured intracranial aneurysms were endovascularly treated by the semi-jailing stent-assisted coiling technique from January,2007 and August,2011.Results The outcomes immediately after the embolization were Raymond class Ⅰ in 26 patients,class Ⅱ in 8 and class Ⅲ in 3.There were no in-stent stenosis or recurrence of aneurysms in 28 patients who were followed up by the cerebral angiography from 3 to 24 months (mean,10.4 months).No bleeding recurred in 36 patients who were clinically followed up from 9 to 48 months (mean,21.3 months).Conclusions The endovascular treatment of ruptured,tiny and wide-necked intracranial aneurysms by the semi-jailing stent-assisted coiling technique is safe and feasible.The long-term curative effects of the endovascular embolization on the ruptured,tiny and wide-necked aneurysms may be further improved by the increase in the packing density and diverting blood flow produced by the semi-jailing stent-assisted coiling

  15. A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Werner; Kuehne, Dietmar [Alfried Krupp Hospital, Department of Radiology and Neuroradiology, Essen (Germany); Bendszus, Martin; Solymosi, Laszlo [University of Wuerzburg, Department of Neuroradiology, Wuerzburg (Germany); Kis, Bernhard [University of Duisburg-Essen, Research Unit, Rheinische Kliniken Essen, Department of Psychiatry and Psychotherapy, Essen (Germany); Boulanger, Thierry [Centre Hospitalier of Luxembourg, Service of Neuroradiology, Luxembourg (Luxembourg)

    2007-07-15

    We report the results of a prospective clinical study using a new self-expanding nitinol stent (Enterprise) designed for the treatment of wide-necked intracranial aneurysms. We treated 31 saccular, wide-necked intracranial aneurysms in 30 patients. Ten aneurysms had recanalized after prior endovascular treatment without a stent, and 21 aneurysms had not been treated before. Stent deployment was successful in all procedures. Additional coil embolization was performed in all aneurysms. Initial complete angiographic occlusion was achieved in 6 aneurysms, a neck remnant was left in 18 aneurysms and there were 7 residual aneurysms. Angiographic follow-up examinations of 30 lesions after 6 months demonstrated 15 complete occlusions, 8 neck remnants and 7 residual aneurysms. One patient refused the 6-month angiographic follow-up. Spontaneous occlusion of the aneurysm had occurred in 14 patients, and 6 aneurysms showed recanalization. Four of these residual aneurysms were retreated. At the 6-month follow-up, 29 parent arteries were unaffected, whereas two parent vessels demonstrated minor asymptomatic narrowing at the stent site. Two patients experienced one or more possible or probable device-related serious adverse events during the 6-month follow-up period. There was no procedural morbidity or mortality at 6 months after the procedure. The reported results demonstrated the safety and feasibility of the Cordis Neurovascular Enterprise stent in the treatment of wide-necked intracranial aneurysms. Initial clinical and angiographic results are favorable. (orig.)

  16. A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysms

    International Nuclear Information System (INIS)

    We report the results of a prospective clinical study using a new self-expanding nitinol stent (Enterprise) designed for the treatment of wide-necked intracranial aneurysms. We treated 31 saccular, wide-necked intracranial aneurysms in 30 patients. Ten aneurysms had recanalized after prior endovascular treatment without a stent, and 21 aneurysms had not been treated before. Stent deployment was successful in all procedures. Additional coil embolization was performed in all aneurysms. Initial complete angiographic occlusion was achieved in 6 aneurysms, a neck remnant was left in 18 aneurysms and there were 7 residual aneurysms. Angiographic follow-up examinations of 30 lesions after 6 months demonstrated 15 complete occlusions, 8 neck remnants and 7 residual aneurysms. One patient refused the 6-month angiographic follow-up. Spontaneous occlusion of the aneurysm had occurred in 14 patients, and 6 aneurysms showed recanalization. Four of these residual aneurysms were retreated. At the 6-month follow-up, 29 parent arteries were unaffected, whereas two parent vessels demonstrated minor asymptomatic narrowing at the stent site. Two patients experienced one or more possible or probable device-related serious adverse events during the 6-month follow-up period. There was no procedural morbidity or mortality at 6 months after the procedure. The reported results demonstrated the safety and feasibility of the Cordis Neurovascular Enterprise stent in the treatment of wide-necked intracranial aneurysms. Initial clinical and angiographic results are favorable. (orig.)

  17. Endovascular treatment of renal aneurysms: A series of 18 cases

    International Nuclear Information System (INIS)

    Purpose: To retrospectively analyze the results and complications of the endovascular treatment of 18 renal aneurysms. Methods: From 2002 to 2011, 15 patients (aged 31–76), with 18 renal aneurysms, were admitted in our institution for treatment by embolization. Except one, all were wide-necked aneurysms. One aneurysm was treated by occluding the parent artery considering its distal location; a small-necked aneurysm was treated by simple coiling, and the remaining 16 were embolized utilizing adjunctive techniques to protect the parent artery. We analyzed the rates of technical success, complication and clinical consequence, post-operative occlusion and recurrence. Results: There was a 100% technical success rate. 15 aneurysms showed a total occlusion on the post-treatment angiogram. 2 aneurysms demonstrated neck remnants, and one had an intrasaccular residual in-flow. Two minor post-operative complications were encountered but resolved over time. No delayed clinical complications were observed and the long-term angiographic follow-up demonstrated stability of the occlusion of the target renal aneurysm with no major recurrence. Conclusion: Complications of the embolization of renal aneurysms are rare. Endovascular treatment should therefore be considered at first for the treatment of renal aneurysms.

  18. Preliminary evaluation of the endovascular treatment of intracranial aneurysms with detachable coils in vigil patients Avaliação preliminar do tratamento endovascular de aneurismas intracranianos com espirais destacáveis em pacientes no estado de vigília

    Directory of Open Access Journals (Sweden)

    José Roberto Falco Fonseca

    2006-12-01

    Full Text Available Endovascular treatment of intracranial aneurysms with coil embolization became the most important therapeutic option with better morbidity and mortality rates and quality of life. Following immobility, patients are treated with general anaesthesia. OBJECTIVE: To test viability of endovascular treatment on wake patients. METHOD: Considering clinical symptoms, psychological characteristics and aneurysmal morphology, four patients with five intracranial aneurysms were selected. RESULTS: Four among five cases were completed with this technique. Patient 1 was partially treated after 75 minutes presenting vesical stress. Patient 2 presented subarachnoid hemorrhage after aneurysmal re-rupture, and the procedure was completed under general anaesthesia. The other three patients presented no intercurrences during the treatment. CONCLUSION: Endovascular treatment on wake patients with intracranial aneurysm can be an alternative to a selected group of patients.O tratamento endovascular de aneurismas intracranianos com espirais destacáveis estabeleceu-se como principal opção terapêutica na maioria dos pacientes, por menores taxas de morbidade e mortalidade. De forma geral, os pacientes são tratados sob anestesia geral, pela necessidade de imobilidade. OBJETIVO: Avaliar a viabilidade do tratamento endovascular de aneurismas intracranianos em pacientes no estado de vigília. MÉTODO: Cinco aneurismas foram tratados em quatro pacientes selecionados, considerando-se quadro clínico, a intenção de colaboração do paciente e características morfológicas do aneurisma. RESULTADOS: A abordagem proposta foi possível em quatro dos cinco casos. O paciente 1 obteve compactação parcial do aneurisma, pois o tratamento foi interrompido por desconforto vesical. O paciente 2 apresentou hemorragia subaracnóidea por re-ruptura do aneurisma, e o tratamento foi completado no mesmo tempo sob anestesia geral. Nos demais casos, não houve intercorrências. CONCLUS

  19. Simultaneous Endovascular Treatment of Ruptured Cerebral Aneurysms and Vasospasm

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Dae; Han, Moon Hee; Kang, Hyun Seung; Kim, Jeong Eun [Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Ahn, Jun Hyoung [Dept. of Neurosurgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang (Korea, Republic of); Jung, Seung Chai [Dept. of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Kim, Chang Hun [Dept. of Neurology, Stroke Center, Myongji Hospital, Goyang (Korea, Republic of); Lim, Jeong Wook [Dept. of Neurosurgery, Sun Hospital, Daejeon (Korea, Republic of)

    2015-02-15

    The management of patients with ruptured cerebral aneurysms and severe vasospasm is subject to considerable controversy. We intended to describe herein an endovascular technique for the simultaneous treatment of aneurysms and vasospasm. A series of 11 patients undergoing simultaneous endovascular treatment of ruptured aneurysms and vasospasm were reviewed. After placement of a guiding catheter within the proximal internal carotid artery for coil embolization, an infusion line of nimodipine was wired to one hub, and of a microcatheter was advanced through another hub (to select and deliver detachable coils). Nimodipine was then infused continuously during the coil embolization. This technique was applied to 11 ruptured aneurysms accompanied by vasospasm (anterior communicating artery, 6 patients; internal carotid artery, 2 patients; posterior communicating and middle cerebral arteries, 1 patient each). Aneurysmal occlusion by coils and nimodipine-induced angioplasty were simultaneously achieved, resulting in excellent outcomes for all patients, and there were no procedure-related complications. Eight patients required repeated nimodipine infusions. Our small series of patients suggests that the simultaneous endovascular management of ruptured cerebral aneurysms and vasospasm is a viable approach in patients presenting with subarachnoid hemorrhage and severe vasospasm.

  20. Application of dual volume reconstruction technique in embolization of intracranial aneurysms

    Directory of Open Access Journals (Sweden)

    Xiang-hai ZHANG

    2014-03-01

    Full Text Available Objective To explore the value of dual volume reconstruction technique in Guglielmi detachable coil (GDC embolization of intracranial aneurysms. Methods Three-dimensional imaging data of 20 patients received GDC embolization of intracranial aneurysms from Jun. 2012 to Apr. 2013 were analyzed for dual volume reconstruction. The value of application of dual volume reconstruction was evaluated by the detection rate of coils bolus, degree of aneurysm occlusion, the length of aneurysm sac and aneurysm neck before and after embolization, and the characteristics and clinical value of the reconstructed images. Results  A total of 20 coil boluses were detected by dual volume reconstruction images, and the detection rate was 100%. Among all of 20 patients, no visualization of contrast medium in the aneurysm was found in 13 patients, while contrast agent was found in the aneurysm sac in 3 patients and in the aneurysm neck in 4 patients. The length of aneurysm neck and sac was somewhat changed before and after embolization with no statistically significant difference (P>0.05. The dual volume reconstruction could reveal coil bolus, vessels, cranium and fusion images, and the aneurysms could be shown by different imaging modes according to the clinical requirement. Conclusion Dual volume reconstruction technique can display the location of coil bolus, degree of occlusion and aneurysm size, and evaluate the embolization effect by multifarious imaging modes, providing a great deal of information for the evaluation of GDC embolization of intracranial aneurysm. DOI: 10.11855/j.issn.0577-7402.2014.02.13

  1. Abdominal Aortic Aneurysms: Treatments

    Science.gov (United States)

    ... access catheters Vertebroplasty Women and vascular disease Women's health Social Media Facebook Twitter ... Abdominal Aortic Aneurysms Interventional Radiologists Treat Abdominal Aneurysms Nonsurgically Interventional radiologists are vascular ...

  2. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    International Nuclear Information System (INIS)

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  3. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenbruch, Georg, E-mail: gmuehlenbruch@ukaachen.de; Nikoubashman, Omid; Steffen, Bjoern; Dadak, Mete [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany); Palmowski, Moritz [RWTH Aachen University, Department of Nuclear Medicine, University Hospital (Germany); Wiesmann, Martin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany)

    2013-02-15

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  4. ALEPH Coil

    CERN Multimedia

    ALEPH was one of the four experiments installed at the LEP particle accelerator from 1989 - 2000. The detector was used by a collaboration of hundreds of physicists, mostly from Europe but also from China and the USA. The ALEPH superconducting magnet coils provide a very uniform magnetic field of 1.5 Tesla. The current in the coil is about 5000 A and the stored energy is 136 MJ. The coils are cooled by liquid Helium. Two correction coils serve to improve the uniformity of the field. This piece is connected to OBJ-DE-054.

  5. Stenting plus coiling: dangerous or helpful?; Stenting plus Coiling bei akut rupturierten intrakraniellen Aneurysmen

    Energy Technology Data Exchange (ETDEWEB)

    Wanke, I.; Gizewski, E.; Doerfler, A.; Stolke, D.; Forsting, M. [Essen Univ. (Germany). Inst. fuer Radiologie und Neuroradiologie

    2005-09-01

    Purpose: the purpose of this study was to evaluate the procedural risk of treating acute ruptured aneurysms with a stentcoil combination. Material and methods: between August 2001 and January 2004 we treated nine acute subarachnoid hemorrhage (SAH) patients with a combination of stents and platinum coils. Results: six aneurysms were 100% eliminated; the residual three aneurysms had a 95% to 99% occlusion. A transient thrombosis in the stent in one patient could be recanalized by intravenous application of ReoPro {sup registered}. In another patient an occlusive vasospasm at the distal end of the stent was successfully treated with intraarterial Nimotop {sup registered}. Neurological complications occurred in none of the patients. Conclusion: in broad-based aneurysms which cannot be clipped or in which any neurosurgical treatment presents an unacceptably high risk (posterior circulation and paraophthalmic aneurysms), treatment using a combination of stent and platinum coils might be an option even in the acute phase of an SAH. Platelet aggregation can be treated with Aspirin registered and Plavix {sup registered} after placement of the first coil, vasospasms with intraarterial Nimotop {sup registered}, and acute stent thrombosis with GP IIa/IIIb-antagonists. (orig.)

  6. Intra-aneurysmal thrombosis induced by stenting in the parent artery in rabbit. Hemodynamic consideration

    International Nuclear Information System (INIS)

    The indication of coil embolization for unruptured aneurysms is recently increasing. However, a safer procedure is required, since the patients are asymptomatic. We presumed that the manipulation in aneurysm can be avoided to prevent rupture if intra-aneurysmal thrombosis is induced with only stenting in the parent artery of aneurysm, and considered whether stenting is effective from a hemodynamic point of view. Neuroform2 is a self-expandable stent used in these experiments. The aneurysm is induced at the origin on the right common carotid artery in rabbits, and the stent introduced into the parent artery of an aneurysm. Aneurysm was also induced in another rabbit without stenting. Intra-aneurysmal partial thrombosis was induced and the volume increased in the term of observation with 3DCT-angiography every month in the stented rabbit. There was no intra-aneurysmal thrombosis in the rabbit without stenting. We also confirmed the decreased intra-aneurysmal velocity in the hemodynamic study using realistic silicon models. These results indicate that intra-aneurysmal partial thrombosis is induced by alteration of the hemodynamics with stenting. This procedure has the possibility for preventing rupture of the aneurysm. We also consider that improvement of the mesh design of the stent and double stenting would lead to complete thrombosis in the aneurysm. (author)

  7. Giant intracranial aneurysms: development, clinical presentation and treatment

    International Nuclear Information System (INIS)

    The natural history of giant intracranial aneurysms are grave. More than 50% of patients suffer from rupture of these aneurysms and mortality is >60% in 2 years. Modern technology and advancement of knowledge in neurosurgery and interventional neuroradiology have altered its natural course for the better. As many reports have shown, the majority of these aneurysms can be treated either by surgery or by endovascular approach, even though morbidity is higher than when treating smaller aneurysms. Certain aneurysms are more suitable to direct surgical clipping and others may have better chances of good clinical outcome by endovascular treatment. It is imperative to analyse the location, morphology, hemodynamics and circulation of normal brain of each aneurysm before the mode of treatment is decided. Needless to say, the individual patient's age, neurological and medical condition should be considered. For endovascular treatment, application of each technique, endosaccular occlusion or parent artery occlusion depends on the aneurysm location and geometry as well as its pathology. Several reports indicated that clinical outcome is better in patients treated by parent artery occlusion since it eliminates any blood flow to the aneurysm and it provides a more effective reduction of the mass effect. However, not all parent arteries can be sacrificed. In addition, endosaccular treatment is effective in preventing haemorrhage if the aneurysm is not re-canalised. It is also demonstrated that symptoms of mass effect can be reversed by endosaccular coiling. The patients who are treated this way should be closely monitored for re-canalisation

  8. Superficial Palmar Arch Aneurysm after Carpal Tunnel Decompression, a Rare Complication: A Case Report

    Directory of Open Access Journals (Sweden)

    S. Gull

    2011-01-01

    Full Text Available False aneurysms of the palmar arteries are rare. They are usually associated with traumatic injuries to the hand vasculature. We present a case of superficial palmar arch aneurysm (SPAA, complicating carpal tunnel decompression which presented as a pulsatile mass at the site of previous surgery. Initial diagnosis was made on clinical examination and confirmed on doppler ultrasound (US and computed tomographic angiography (CTA. The feeding vessel of the aneurysm was subsequently occluded using coil embolization.

  9. Hemodynamic Alterations after Stent Implantation in 15 Cases of Intracranial Aneurysms

    Science.gov (United States)

    Wang, Chao; Tian, Zhongbin; Liu, Jian; Jing, Linkai; Paliwal, Nikhil; Wang, Shengzhang; Zhang, Ying; Xiang, Jianping; Siddiqui, Adnan H; Meng, Hui; Yang, Xinjian

    2016-01-01

    Background Stent-assisted coiling technology has been widely used in the treatment of intracranial aneurysms. In current study, we investigated the intra-aneurysmal hemodynamic alterations after stent implantation and its association with aneurysm location. Methods We first retrospectively studied 15 aneurysm cases (8 internal carotid artery-ophthalmic artery (ICA-OphA) aneurysms and 7 posterior communicating artery (PcoA) aneurysms) treated with Enterprise stents and coils. Then based on patient-specific geometries before and after stenting, we built virtual stenting computational fluid dynamics (CFD) simulation models. Results Before and after stent deployment, the average Wall Shear Stress (WSS) on the aneurysmal sac at systolic peak changed from 7.04 Pa (4.14 Pa, 15.77 Pa) to 6.04 Pa (3.86 Pa, 11.13 Pa), P = 0.001; and the spatially averaged value of flow velocity in the perpendicular plane of aneurysm dropped from 0.5 m/s (0.28 m/s, 0.7 m/s) to 0.33 m/s (0.25 m/s, 0.49 m/s), P = 0.001, respectively. Post-stent implantation, WSS in ICA-OphA aneurysms and PcoA aneurysms decreased by 14.4% (P = 0.012) and 16.6% (P = 0.018) respectively, and flow velocity also reduced by 10.3% (P = 0.029) and 10.5% (P = 0.013), respectively. Changes in WSS, flow velocity, and pressure were not significantly different between ICA-OphA aneurysms and PcoA aneurysms (P > 0.05). Stent implantation did not significantly change the peak systolic pressure in both aneurysm types. Conclusion After stent implantation, intra-aneurysmal flow velocity and WSS decreased independent of aneurysm type (ICA-OphA and PcoA). Little change was observed on peak systolic pressure. PMID:26746828

  10. Asymptomatic giant coronary aneurysm in an adolescent with Behcet's syndrome

    Directory of Open Access Journals (Sweden)

    Kahn Philip J

    2012-01-01

    Full Text Available Abstract Objective Behcet's is an idiopathic multi-organ syndrome, which may have onset during childhood. Vascular involvement is uncommon, with rarely reported coronary aneurysm formation. We present a case report of a teenager girl who developed recalcitrant life-threatening Behcet's vasculitis, involving both small and large venous and arterial systems including a giant coronary aneurysm. Case report De-identified data were collected retrospectively in case report format. Although our sixteen year old female with Behcet's vasculitis had resolution of many arterial aneurysms, she had persistent venous thrombosis of large vessels, as well as persistent, giant arterial aneurysms requiring intra-arterial coiling of a lumbar artery and coronary bypass grafting despite intensive immunosuppression including glucocorticoids, cyclophosphamide, infliximab, methotrexate, azathioprine and intravenous immunoglobulin. Conclusions Vascular manifestations may be seen in Behcet's syndrome, including asymptomatic coronary aneurysm, which may be refractory to immunosuppression and ultimately require surgical intervention. Increased awareness is essential for prompt diagnosis and management.

  11. Endovascular interventions for descending thoracic aortic aneurysms: The pivotal role of the clinical nurse in postoperative care.

    Science.gov (United States)

    Dolinger, Cami; Strider, David V

    2010-12-01

    Descending thoracic aortic aneurysms (dTAA) comprise 40% of all aneurysms arising from the thoracic aorta. Because rupture of thoracic aneurysms is associated with a 94% mortality rate, timely detection, surveillance and treatment is imperative. Endovascular stent-graft repair of thoracic aneurysms was first performed in 1992 and has become an accepted treatment option for this condition in select candidates. There is an abundance of information for the care of patients after open surgical repair of dTAA. However, still relatively few written guidelines exist in the nursing literature for postoperative care and complications associated with endovascular stent-graft repair. The prevalence of aortic endografting, however, now makes it necessary for nurses to have a solid knowledge base in the operative procedure, complications and postoperative care for this patient population. Ideal candidates for aortic endografting undergo CTA or MRI preoperatively and fit a set of strict anatomic criteria to ensure proper delivery and fixation of the device. The early postoperative care focuses on minimizing pulmonary complications, paraplegia, renal failure and embolic complications such as stroke and limb ischemia through skilled nursing assessment and interventions. Late complications such as stent-graft migration, kinking, stent fracture and endoleak are often without symptoms, making it necessary for patients to be educated about these potential complications and to be encouraged to comply with lifelong follow up. This overview provides a sound cognitive framework for nurses practicing in a vascular surgery milieu. PMID:21074117

  12. Transcatheter Embolization of a Renal Arteriovenous Fistula Complicated by an Aneurysm of the Feeding Renal Artery

    International Nuclear Information System (INIS)

    Renal arteriovenous fistula (AVF) is rare. Renal AVF complicated by aneurysm of the feeding artery presents a technical challenge for endovascular treatment. We report a case managed by covered stenting of the renal artery aneurysm, coil embolization of the fistula, and bare stenting of the aorta

  13. Wall shear stress in intracranial aneurysms and adjacent arteries

    Institute of Scientific and Technical Information of China (English)

    Fuyu Wang; Bainan Xu; Zhenghui Sun; Chen Wu; Xiaojun Zhang

    2013-01-01

    Hemodynamic parameters play an important role in aneurysm formation and growth. However, it is difficult to directly observe a rapidly growing de novo aneurysm in a patient. To investigate possible associations between hemodynamic parameters and the formation and growth of intracranial aneurysms, the present study constructed a computational model of a case with an internal carotid artery aneurysm and an anterior communicating artery aneurysm, based on the CT angiography findings of a patient. To simulate the formation of the anterior communicating artery aneurysm and the growth of the internal carotid artery aneurysm, we then constructed a model that virtually removed the anterior communicating artery aneurysm, and a further two models that also progressively decreased the size of the internal carotid artery aneurysm. Computational simulations of the fluid dynamics of the four models were performed under pulsatile flow conditions, and wall shear stress was compared among the different models. In the three aneurysm growth models, increasing size of the aneurysm was associated with an increased area of low wall shear stress, a significant decrease in wall shear stress at the dome of the aneurysm, and a significant change in the wall shear stress of the parent artery. The wall shear stress of the anterior communicating artery remained low, and was significantly lower than the wall shear stress at the bifurcation of the internal carotid artery or the bifurcation of the middle cerebral artery. After formation of the anterior communicating artery aneurysm, the wall shear stress at the dome of the internal carotid artery aneurysm increased significantly, and the wall shear stress in the upstream arteries also changed significantly. These findings indicate that low wall shear stress may be associated with the initiation and growth of aneurysms, and that aneurysm formation and growth may influence hemodynamic parameters in the local and adjacent arteries.

  14. Using Onyx in endovascular embolization of internal carotid artery large or giant aneurysms

    International Nuclear Information System (INIS)

    Background and purpose: Internal carotid artery (ICA) large or giant saccular aneurysms is challenging for endovascular coil embolization and surgical clipping with a high recanalization and rebleeding rate. We report our results using Onyx in the endovascular treatment of ICA large or giant saccular aneurysms. Methods: During 2008–2010, 5 patients with 5 large or giant saccular aneurysms in ICA were treated with a liquid embolic agent (Onyx; Micro Therapeutics, Irvine, CA). One aneurysm was small (<10 mm), 2 were large (≥10 mm, <25 mm) and 2 were giant saccular aneurysms (≥25 mm). Of 3 female and 2 male patients, 3 were incidental and 2 had bleeding. Selective embolization was performed with Onyx alone or a combination with coils. Clinical and anatomic outcomes were assessed with the Modified Glasgow Outcome Scale and follow-up angiography was performed at 4–21 months (mean 12.2 months). Results: Complete aneurysm occlusion was obtained in all of the aneurysms on immediate control angiogram. There was not any procedure-related complication. No recanalization was observed at the follow- up periods. There were 2 ICA occlusions in giant ICA aneurysms. The 5 patients were all clinically asymptomatic at follow-up. Conclusion: Endovascular embolization with Onyx is a useful treatment for ICA large or giant aneurysms, which is unsuitable for coiling or surgical treatment.

  15. ABDOMINAL AORTIC ANEURYSM (AAA

    Directory of Open Access Journals (Sweden)

    Rajesh G

    2011-11-01

    Full Text Available AAA is defined as a distension of the infrarenal aorta by more than 50% (or 1.5 times compared with a corresponding healthy, aged and gender matched population. AAA afflicts 1 to 6 % of the general population aged more than 60 years and the incidence rises by approximately 0.15% annually. When the definition of a maximum external diameter ≥3 cm is used, the prevalence of AAA is upto 6 times greater in men than in women. AAAs are much more common than thoracic aortic aneurysms. Most common cause of AAA is atherosclerosis (95%. Less common causes include infectious or inflammatory origin or those associated with connective tissue disorders. Process of AAA formation is multifactorial. Other than the general risk factors for atherosclerosis, genetic predispo s iti on, aut o immunity and hemodynamic factors all play roles in its formation. AAA is 1.5 times more frequent in hypert ensive patients. Smokers have 8 times risk for developing AAA. The existence of familial aggre gation of AAA implicates genetic factors in the etiology of AAA. Women with AAA are more likely to have a positive family history of this disorder. Those with a family history of AAA have an increased risk of 30%, and their aneurysms tend to occur at a younger age and carry a greater risk of rupture than do sporadic aneurysms.

  16. Brain Aneurysm: Early Detection and Screening

    Science.gov (United States)

    ... Brain Aneurysm Statistics and Facts Seeking Medical Attention Pediatric Aneurysms Brain Aneurysm Causes and Risk Factors Family History ... Brain Aneurysm Statistics and Facts Seeking Medical Attention Pediatric Aneurysms Brain Aneurysm Causes and Risk Factors Family History ...

  17. Brain Aneurysm Warning Signs/Symptoms

    Science.gov (United States)

    ... Brain Aneurysm Statistics and Facts Seeking Medical Attention Pediatric Aneurysms Brain Aneurysm Causes and Risk Factors Family History ... Brain Aneurysm Statistics and Facts Seeking Medical Attention Pediatric Aneurysms Brain Aneurysm Causes and Risk Factors Family History ...

  18. Basilar artery aneurysm at a persistent trigeminal artery junction. A case report and literature review.

    Science.gov (United States)

    Aguiar, G B; Conti, M L M; Veiga, J C E; Jory, M; Souza, R B

    2011-09-01

    The trigeminal artery is an anastomosis between the embryonic precursors of the vertebrobasilar and carotid systems, and may persist into adult life. The association of the persistent primitive trigeminal artery (PTA) with cerebral aneurysm is well documented in the literature and, in general, aneurysms are located in the anterior circulation. We describe a patient who presented with a panencephalic Fisher III subarachnoid hemorrhage due to rupture of an intracranial aneurysm. Digital arteriography showed a saccular aneurysm in the middle third of the basilar artery, adjacent to the junction with a persistent trigeminal artery. She was submitted to endovascular treatment with embolization of the basilar artery aneurysm with coils. Aneurysms at the PTA junction with the basilar artery are rare. This paper describes a case of PTA associated with an aneurysm in the basilar artery at PTA junction and briefly reviews the literature. PMID:22005697

  19. Flat-detector computed tomography evaluation in an experimental animal aneurysm model after endovascular treatment: A pilot study.

    Science.gov (United States)

    Ott, Sabine; Gölitz, Philipp; Adamek, Edyta; Royalty, Kevin; Doerfler, Arnd; Struffert, Tobias

    2015-08-01

    We compared flat-detector computed tomography angiography (FD-CTA) to multislice computed tomography (MS-CTA) and digital subtracted angiography (DSA) for the visualization of experimental aneurysms treated with stents, coils or a combination of both.In 20 rabbits, aneurysms were created using the rabbit elastase aneurysm model. Seven aneurysms were treated with coils, seven with coils and stents, and six with self-expandable stents alone. Imaging was performed by DSA, MS-CTA and FD-CTA immediately after treatment. Multiplanar reconstruction (MPR) was performed and two experienced reviewers compared aneurysm/coil package size, aneurysm occlusion, stent diameters and artifacts for each modality.In aneurysms treated with stents alone, the visualization of the aneurysms was identical in all three imaging modalities. Residual aneurysm perfusion was present in two cases and visible in DSA and FD-CTA but not in MS-CTA. The diameter of coil-packages was overestimated in MS-CT by 56% and only by 16% in FD-CTA compared to DSA (p metal hardening artifacts impaired image quality more severely in MS-CTA compared to FD-CTA.MS-CTA is impaired by blooming and beam/metal hardening artifacts in the visualization of implanted devices. There was no significant difference between measurements made with noninvasive FD-CTA compared to gold standard of DSA after stenting and after coiling/stent-assisted coiling of aneurysms. FD-CTA may be considered as a non-invasive alternative to the gold standard 2D DSA in selected patients that require follow up imaging after stenting. PMID:26111985

  20. Preliminary clinical study on endovascular treatment of posterior inferior cerebellar artery aneurysms

    International Nuclear Information System (INIS)

    Objective: To study the methods and results of endovascular treatment of posterior inferior cerebellar artery (PICA) aneurysms. Methods: Twenty-one patients with PICA aneurysms were treated with endovascular treatment. The locations of aneurysm on PICA were evaluated through the DSA. Eight patients received single coil embolization, 5 received liquid Glue embolization, 2 received coil embolization combined with liquid Glue, 2 received coil embolization assisted with stents, and 4 underwent occlusion of the parent PICA. Outcome was evaluated with the Glasgow outcome scale (GOS). Results: There were complete (100%) occlusion in 5 patients, near complete (> 90%) occlusion in 2, and incomplete (85%) occlusion in 1 in single coil embolization. Seven patients with Glue embolization (n=5) or combination with coils (n=2) exhibited complete (100%) occlusion. There were near complete (>90%) occlusion in 2 cases with coil assisted with stents. Complete occlusion of the parent PICA was achieved in 3 patients, and near complete occlusion of PICA in one case. One patient suffered from new neurological deficits, and one patient treated with coils and stents died. None of the patients suffered from re-bleeding. There patients received follow-up during a mean period of (22 ± 8) months. Overall long-term outcome was good (GOS score 4 or 5) in 17 patients, poor (GOS score 2 or 3) in 3, and fatal (GOS score 1 ) in one case. Conclusions: According to the location of aneurysms on PICA, aneurysms can be effectively and safely treated with endovascular embolization. (authors)

  1. Endovascular treatment of experimentally induced aneurysms in rabbits using stents: a feasibility study

    International Nuclear Information System (INIS)

    Although Guglielmi detachable coil (GDC) systems have been generally accepted for treatment of intracranial aneurysms, primary stenting of aneurysms using porous stents or implantation of coils after stent placement remains experimental. Testing of these new methods requires an animal model which imitates human aneurysms in size, configuration and neck morphology. We assessed in detail the technical requirements of and steps for transfemoral stent treatment of experimentally induced aneurysms at the top of the brachiocephalic trunk in rabbits. We created aneurysms in ten rabbits by distal ligation and intraluminal digestion of the right common carotid artery with elastase. We treated five animals with porous stents alone, and five with stents plus coiling via the meshes of the stent, which permitted dense packing of coils. No complications related to the procedures occurred. In all animals, even in those treated solely with porous stents, total occlusion of the aneurysm was achieved. Our animal model can be suitable for testing the biocompatibility and occlusion rate of new methods and devices for the treatment of experimental aneurysms. (orig.)

  2. GDC embolization of wide-necked cerebral aneurysms using balloon-assisted technique

    International Nuclear Information System (INIS)

    The main factor limiting endovascular treatment of intracranial aneurysms is the shape of the aneurysmal sac, especially the width of the neck. We describe an early experience and technical aspects of treating wide-necked cerebral aneurysm using a Guglielmi detachable coil (GDC) and simultaneous application of a temporary balloon. Four cases of unruptured wide-necked cerebral aneurysm were treated with GDC, with simultaneous application of a temporary balloon. Patients were aged between 29 and 49 years. On admission, clinical presentation was subarachnoid hemorrhage (SAH) in all cases. Hunt and Hess grade was 2 in two cases, 3 in one case, and traumatic SAH in one case. In all patients angiography revealed an asymptomatic aneurysm after rupture of another aneurysm or traumatic SAH. The aneurysms were occluded with GDC-10, and a Cirrus balloon occlusion system was used simultaneously. All procedures were performed under endotracheal general anesthesia and systemic heparinization. All cases were treated successfully, without parent artery compromise. The occlusion rate at the end of the procedure was total in three cases and subtotal in one. In one case a heparin-related hematoma occurred during post-procedural treatment and the patient eventually expired. One patient underwent follow-up angiography after 6 months, and the coil was not changed. An aneurysm may not be completely occluded, but with regard to coil compaction and parent artery preservation, the technique is an attractive alternative

  3. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... to become you to our live webcast. Today we’re going to repair an abdominal aortic aneurysm ... and together as a team of multidisciplinary physicians, we’re going to repair an abdominal aortic aneurysm ...

  4. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... for the past three years, and his aneurysm has now grown to 5.4 centimeters. And this ... that in this particular patient that the aneurysm has reached the size where risk of rupture when ...

  5. Cerebral Aneurysms Fact Sheet

    Science.gov (United States)

    ... cerebral aneurysm from forming. People with a diagnosed brain aneurysm should carefully control high blood pressure, stop smoking, and avoid cocaine use or other stimulant drugs. They should also ...

  6. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... is actually an important factor. Most aneurysms we treat conservatively and we’ll just watch them. But ... has to be, and we generally don’t treat aneurysms until they get to be 5 to ...

  7. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... atherosclerosis, high blood pressure, smokers, or a family history of abdominal aortic aneurysms. Today’s patient is a ... screened. In fact, patients who have a family history of aneurysm, men who are smoking over the ...

  8. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... as atherosclerosis, high blood pressure, smokers, or a family history of abdominal aortic aneurysms. Today’s patient is ... be screened. In fact, patients who have a family history of aneurysm, men who are smoking over ...

  9. Aortic Aneurysm Statistics

    Science.gov (United States)

    ... connective tissue disorders, such as Marfan syndrome and Ehlers-Danlos syndrome, get thoracic aortic aneurysms. Signs and symptoms of thoracic aortic aneurysm can include Sharp, sudden pain in the chest or upper back. Shortness of ...

  10. Paediatric intracranial aneurysms

    Directory of Open Access Journals (Sweden)

    A A Wani

    2006-01-01

    Full Text Available Intracranial aneurysms in childhood account for 1-2% of intracranial aneurysms.[1],[2] These aneurysms have unique characteristics that make them different from those in adults. These differences are evident in their epidemiology, location, clinical spectrum, association with trauma and infection, complications and outcome.

  11. Image-based analysis of blood flow modification in stented aneurysms

    Science.gov (United States)

    Cebral, Juan; Mut, Fernando; Appanaboyina, Sunil; Löhner, Rainald; Miranda, Carlos; Escrivano, Esteban; Lylyk, Pedro; Putman, Christopher

    2009-02-01

    Currently there is increased interest in the use of stents as flow diverters for the treatment of intracranial aneurysms, especially wide necked aneurysms that are difficult to treat by coil embolization or surgical clipping. This paper presents image-based patient-specific computational models of the hemodynamics in cerebral aneurysms before and after treatment with a stent alone, with the goal of better understanding the hemodynamic effects of these devices and their relation to the outcome of the procedures. Stenting of cerebral aneurysms is a feasible endovascular treatment option for aneurysms with wide necks that are difficult to treat with coils or by surgical clipping. However, this requires stents that are capable of substantially modifying the intra-aneurysmal flow pattern in order to cause thrombosis of the aneurysm. The results presented in this paper show that the studied stent was able to change significantly the hemodynamic characteristics of the aneurysm. In addition, it was shown that patient-specific computational models constructed from medical images are capable of realistically representing the in vivo hemodynamic characteristics observed during conventional angiography examinations before and after stenting. This indicates that these models can be used to better understand the effects of different stent designs and to predict the alteration in the hemodynamic pattern of a given aneurysm produced by a given flow diverter. This is important for improving current design of flow diverting devices and patient treatment plans.

  12. Role of 3T multiparametric magnetic resonance imaging without endorectal coil in the detection of local recurrent prostate cancer after radical prostatectomy: the radiation oncology point of view

    OpenAIRE

    Couñago, Felipe; Cerro, Elia del; Díaz, Ana Aurora; Marcos, Francisco José; Cerezo, Laura; Maldonado, Antonio; Thuissard Vasallo, Israel John; Rodríguez Martín, José Luis

    2015-01-01

    The aims of this study were to evaluate the role of 3 tesla multiparametric magnetic resonance imaging (3TmMRI) without endorectal coil in the detection of radiographic local recurrences (rLRs) in a contemporary cohort of patients with prostate cancer who presented with biochemical recurrence after radical prostatectomy (RP) with low prostate-specific antigen (PSA) levels, and to identify clinical parameters associated with the 3TmMRI findings.

  13. Dual-energy computed tomography after endovascular aortic aneurysm repair: The role of hard plaque imaging for endoleak detection

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Wille, R.; Borgmann, T.; Wohlgemuth, W.A.; Jung, E.M.; Heiss, P.; Schreyer, A.G.; Stroszczynski, C.; Dornia, C. [Institute of Radiology, University Medical Center Regensburg, Regensburg (Germany); Zeman, F. [University Medical Center Regensburg, Center for Clinical Studies, Regensburg (Germany); Pfister, K. [University Medical Center Regensburg, Department of Surgery, Regensburg (Germany); Krauss, B. [Siemens AG, Healthcare Sector, Forchheim (Germany)

    2014-10-15

    To assess the diagnostic accuracy of dual-energy computed tomography (DECT) for detection of endoleaks and aneurysm sac calcifications after endovascular aneurysm repair (EVAR) using hard plaque imaging algorithms. One hundred five patients received 108 triple-phase contrast-enhanced CT (non-contrast, arterial and delayed phase) after EVAR. The delayed phase was acquired in dual-energy and post-processed using the standard (HPI-S) and a modified (HPI-M) hard plaque imaging algorithm. The reference standard was determined using the triple-phase CT and contrast-enhanced ultrasound. All images were analysed separately for the presence of endoleaks and calcifications by two independent readers; sensitivity, specificity and interobserver agreement were calculated. Endoleaks and calcifications were present in 25.9 % (28/108) and 20.4 % (22/108) of images. The HPI-S images had a sensitivity/specificity of 54 %/100 % (reader 1) and 57 %/99 % (reader 2), the HPI-M images of 93 %/92 % (reader 1) and 96 %/92 % (reader 2) for detection of endoleaks. For detection of calcifications HPI-S had a sensitivity/specificity of 91 %/99 % (reader 1) and 95 %/97 % (reader 2), the HPI-M images of 91 %/99 % (reader 1) and 91 %/99 % (reader 2), respectively. Using HPI-M, DECT enables an accurate diagnosis of endoleaks after EVAR and allows distinguishing between endoleaks and calcifications with high diagnostic accuracy. (orig.)

  14. Glue embolization of the giant aneurysm by reducing thrombosis-induced volume expansion effect

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Yoo Kyung; Suh, Dae Chul [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2015-04-15

    A giant aneurysm due to a large intra-aneurysmal volume can be complicated by a delayed massive volume expansion caused by thrombus formation. To prevent such a severe mass effect, we obliterated the aneurysmal lumen by gluing and prevented further development of thrombosis. A 52-year-old female with a giant aneurysm at the cavernous segment of the internal carotid artery presented with tinnitus and intermittent diplopia. After confirming with a negative occlusion test, the right internal carotid artery was trapped by coiling and with further obliteration of the aneurysmal lumen by gluing. She developed a mild diplopia after the procedure and recovered without any deficit. The magnetic resonance angiography showed a stable occlusion of the aneurysm and good collateral filling of the cerebral vessel 15 months later.

  15. Therapeutic decision and management of aneurysmal subarachnoid haemorrhage based on computed tomographic angiography.

    Science.gov (United States)

    Dehdashti, A R; Rufenacht, D A; Delavelle, J; Reverdin, A; de Tribolet, N

    2003-02-01

    The purpose of this study was to evaluate the potential of high quality computed tomographic angiography (CTA) to replace digital subtraction angiography (DSA) in cases of ruptured saccular aneurysms and perform early surgical clipping or coiling on the basis of CTA alone. In a prospective study, 100 patients with aneurysmal subarachnoid haemorrhage (SAH) diagnosed by computed tomography underwent CTA. CTA revealed a total of 118 aneurysms including all ruptured aneurysms. A decision of direct surgical clipping, endovascular coiling or therapeutic abstention was made in 89 cases (89%) on the basis of CTA alone. Sixty-one direct surgical procedures were performed after CTA. Twenty-six cases underwent DSA for immediate endovascular treatment of the ruptured aneurysm. In 11 cases (11%), a DSA was performed prior to the therapeutic decision because of unclear aneurysm. Four cases were not treated because of initial poor clinical grade. The surgical findings were compared with CTA data and were considered accurate in all but one case. All patients underwent postoperative DSA within 10 days after SAH. The sensitivity and the specificity of CTA for the detection of all aneurysms, as compared with postoperative DSA, were 95.1 and 100%, respectively. A total of six unruptured aneurysms were missed initially, but were visible retrospectively on CTA in all but one case and were found in patients with multiple aneurysms in whom the ruptured aneurysm was detected by CTA. Current quality CTA allows reliable pretreatment planning for the majority of cases of aneurysmal subarachnoid haemorrhage and diminishes the pretreatment evaluation time critically. Complementary pretreatment DSA is required in situations where CTA characteristics of the ruptured aneurysm is unsatisfactory. PMID:12779201

  16. Brain Aneurysm Statistics and Facts

    Science.gov (United States)

    ... Statistics and Facts A- A A+ Brain Aneurysm Statistics and Facts An estimated 6 million people in ... Understanding the Brain Warning Signs/ Symptoms Brain Aneurysm Statistics and Facts Seeking Medical Attention Risk Factors Aneurysm ...

  17. Prevention and management of the complications during embolizing intracranial aneurysm with GDC

    International Nuclear Information System (INIS)

    Objective: To sum up the experience of embolization of intracranial aneurysm with Guglielmi detachable coil (GDC) and to discuss how to prevent and manage the complications during the endovascular treatment. Methods: 108 patients with intracranial aneurysm were embolized with GDC. 24 accident out of 20 patients during embolization were reviewed. Results: Among the 24 accidents, there were 10 aneurysm rupture, 5 over- embolization 5 coils end protruding to parent artery, and 4 thrombosis. Once the aneurysm ruptures, neutralizing heparin and continuing embolization was administered. Among 10 cases of aneurysm ruptures, 4 were death, 1 was severe deformity, 1 was mild deformity. Thrombolysis, heparinisation and raising blood pressure were used to control over-embolization, coil protrusion, and thrombosis. Among 5 cases of over-embolization, 1 died, 4 recovered. Among 5 cases of coils end protruding, 1 was severe deformity, 1 was mild deformity. Among 4 cases of embolization, 1 died, 1 was led sensory aphasics. The accidents resulted in 5 deaths (4.6%), 4 permanent neurological deficits (3.7%). Conclusion: The correct management of the complications during the treatment, the better understanding of the aneurysm and its parent artery angio-anatomy and the improved skill of embolizing technique are helpful to reduce the accidents and increase the cure rate

  18. Trials and tribulations: an evidence-based approach to aneurysm treatment.

    Science.gov (United States)

    Sorenson, Thomas; Lanzino, Giuseppe

    2016-03-01

    Since the introduction of embolic coils in the early 1990s, endovascular treatment has gained much traction for use when treating ruptured and unruptured intracranial aneurysms. Three prospective studies have been conducted comparing endovascular coil embolization versus clipping for ruptured intracranial aneurysms. The first study took place in Finland and was the first head-to-head look at treating ruptured aneurysms by either endovascular coiling or surgical clipping. Results from this study suggested better functional outcome after endovascular treatment than surgery at the expenses of higher rates of incomplete aneurysm occlusion. The second largest and only multicenter study was the International Subarachnoid Aneurysm Trial (ISAT). The ISAT took place across Europe and was the first large-scale comparison between endovascular and surgical treatments. The results from this study caused a major opinion shift across the world in regards to optimal treatment of ruptured aneurysms. Additionally, the quantity of data from this study allowed for many subgroup analyses to be made. However, to assess the generalizability of the ISAT study, the Barrow Neurological Institute investigators conducted a single-center study. The intent of this latter study was to remove any potential bias and preselection by enrolling every consenting patient that presented with the designated pathology without any exclusion. However, this enrollment strategy resulted in a high percentage of patients with aneurysms not suitable for endovascular therapy being assigned to the coil group which in turn resulted in a high rate of turn over from the endovascular to the surgical arm of the study. Despite, these limitations, this latter trial presented similar results as the Kuopio and ISAT. Although each of these trials was not methodologically flawless, the combined results from all three suggest that endovascular treatment of ruptured aneurysms suitable for this treatment strategy results in

  19. Use of triple microcatheters for endovascular treatment of wide-necked intracranial aneurysms: A single center experience

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Dae; Rhim, Jong Kook; Kang, Hyun Seung; Kim, Jeong Eun; Cho, Won Sang; Han, Moon Hee [Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Park, Jeong Jin [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Jeon, Jin Pyeong [Dept. of Neurosurgery, Kangwon National University Hospital, Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2015-10-15

    The dual microcatheter technique is common practice for coil embolization of a wide-necked aneurysm, due to safety and efficacy. However, technical limitations of some complex configurations may necessitate additional microcatheters to bolster coil stability, compact the coil, or for protection. Described herein is a triple microcatheter technique for endovascular management of wide-necked intracranial aneurysms. Data accruing prospectively between January 2006 and October 2014 on simultaneously executed triple microcatheter coil embolization procedures done in 38 saccular aneurysms were reviewed. Clinical and morphological outcomes were assessed, with emphasis on technical aspects of treatment. The triple microcatheter technique was successfully applied to all 38 saccular aneurysms, involving the posterior communicating artery (n = 13), the middle cerebral artery (n = 10), the basilar tip (n = 7), the anterior cerebral artery (n = 5), and the internal carotid artery (n = 3). Stent protection was added in four patients and balloon remodeling in one. Dual microcatheters (n = 24) were usually deployed to deliver the coil within sacs of aneurysms, with the additional microcatheter used for protection. Otherwise, triple microcatheters were deployed for coil delivery (n = 11) or coils were delivered via a single microcatheter, with dual microcatheters deployed for protection (n = 3). Successful occlusion of aneurysms was achieved in 89.5% of cases, with no procedure-related morbidity or mortality. Stable occlusion was maintained in 72.2% (26/36) of the aneurysms at the final follow-up (mean interval, 30.2 ± 22.7 months). The outcomes of this limited study suggest that the triple microcatheter technique may be an effective and safe therapeutic option for wide-necked aneurysms, using technical strategies tailored to complex angio-anatomic configurations.

  20. Pediatric cerebral artery aneurysms

    OpenAIRE

    Koroknay-Pál, PÀivi

    2012-01-01

    Objectives. Intracranial aneurysms in children are rare and population-based long-term follow-up studies are limited. In this study, a large clinical and angiographic long-term follow-up was carried out. The special characteristics of the patients and their aneurysms were assessed together with factors affecting early and long-term morbidity and mortality. Materials and Methods. All pediatric (≀18 years) aneurysm patients treated at the Department of Neurosurgery in Helsinki during 193...

  1. Carotid-cavernous fistula caused by rupture of persistent primitive trigeminal artery trunk aneurysm--case report.

    Science.gov (United States)

    Yoshida, Masahiro; Ezura, Masayuki; Mino, Masaki

    2011-01-01

    A 60-year-old female presented with a carotid-cavernous fistula (CCF) manifesting as left abducens nerve palsy. Left internal carotid digital subtraction angiography showed a persistent primitive trigeminal artery (PPTA) near the CCF. Super-selective angiography showed direct shunt flow between the PPTA trunk aneurysm and the left cavernous sinus. The aneurysm was successfully occluded with detachable coils. The CCF disappeared and the PPTA was preserved. The abducens nerve paralysis had disappeared 6 months later. CCF caused by a PPTA trunk aneurysm is extremely rare. We speculate that the PPTA trunk aneurysm formed and then ruptured due to hemodynamic stress caused by hypoplasia of the basilar artery. PMID:21785245

  2. Volume changes of extremely large and giant intracranial aneurysms after treatment with flow diverter stents

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Angelo; Byrne, James V. [ohn Radcliffe Hospital, Oxford Neurovascular and Neuroradiology Research Unit, Nuffield Department of Surgical Sciences, Oxford (United Kingdom); Rane, Neil; Kueker, Wilhelm; Cellerini, Martino; Corkill, Rufus [John Radcliffe Hospital, Department of Neuroradiology, Oxford (United Kingdom)

    2014-01-15

    This study assessed volume changes of unruptured large and giant aneurysms (greatest diameter >20 mm) after treatment with flow diverter (FD) stents. Clinical audit of the cases treated in a single institution, over a 5-year period. Demographic and clinical data were retrospectively collected from the hospital records. Aneurysm volumes were measured by manual outlining at sequential slices using computerised tomography (CT) or magnetic resonance (MR) angiography data. The audit included eight patients (seven females) with eight aneurysms. Four aneurysms involved the cavernous segment of the internal carotid artery (ICA), three the supraclinoid ICA and one the basilar artery. Seven patients presented with signs and symptoms of mass effect and one with seizures. All but one aneurysm was treated with a single FD stent; six aneurysms were also coiled (either before or simultaneously with FD placement). Minimum follow-up time was 6 months (mean 20 months). At follow-up, three aneurysms decreased in size, three were unchanged and two increased. Both aneurysms that increased in size showed persistent endosaccular flow at follow-up MR; in one case, failure was attributed to suboptimal position of the stent; in the other case, it was attributed to persistence of a side branch originating from the aneurysm (similar to the endoleak phenomenon of aortic aneurysms). At follow-up, five aneurysms were completely occluded; none of these increased in volume. Complete occlusion of the aneurysms leads, in most cases, to its shrinkage. In cases of late aneurysm growth or regrowth, consideration should be given to possible endoleak as the cause. (orig.)

  3. Systemic Multiple Aneurysms Caused by Vascular Ehlers-Danlos Syndrome.

    Science.gov (United States)

    Gui, Xinyu; Li, Fangda; Wu, Lingeer; Zheng, Yuehong

    2016-07-01

    Systemic multiple aneurysms are rare and usually associated with collagen tissue disease, such as Ehlers-Danlos syndrome (EDS) or Marfan syndrome. In the present case, we describe a 39-year-old male patient with systemic multiple aneurysms and acute intraperitoneal hemorrhage who was clinically diagnosed with vascular EDS. Coil embolization of the distal segment of the common hepatic artery was performed, which resolved the patient's symptoms. With this case presentation, we aim to increase the awareness of vascular EDS among clinicians and emphasize the extreme fragility of the arteries in patients with vascular EDS. PMID:27206743

  4. Role of 123I-IMP SPET in the early diagnosis of borderline chronic hydrocephalus after aneurysmal subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Chronic hydrocephalus after aneurysmal subarachnoid haemorrhage (SAH) is easily diagnosed in most cases. However, the diagnosis is sometimes difficult in borderline cases, in which (a) pathognomonic clinical deterioration due to hydrocephalus is masked by the neurological deficits caused in the acute stage of SAH and (b) ventricular enlargement is not so marked on CT scan. The purpose of this study was to investigate whether or not iodine-123 labelled N-isopropyl-p-iodoamphetamine (123I-IMP) single-photon emission tomography (SPET) is of value for the early diagnosis of borderline chronic hydrocephalus after SAH. Fifteen patients who met the criteria of borderline chronic hydrocephalus were selected for the study, and underwent a shunt operation. The patients were divided into a shunt-effective group and a shunt-ineffective group according to neurological improvement after the shunt operation. 123I-IMP SPET was performed in the acute stage of SAH, within 1 week before the shunt operation, and 2 weeks after the shunt operation. Regional cerebral blood flow was estimated by the 123I-IMP autoradiographic method. Pre-shunting periventricular low-perfusion areas showed statistically significant differences between the two groups (P123I-IMP SPET can be used for both the early diagnosis of borderline chronic hydrocephalus after SAH and the prediction of shunt effectiveness. (orig.)

  5. Intraorbital ophthalmic artery aneurysm associated with basilar tip saccular aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Dehdashti, A.R.; Tribolet, N. de [Department of Neurosurgery, HUG, Geneva (Switzerland); Safran, A.B. [Department of Ophthalmology, HUG, Geneva (Switzerland); Martin, J.B.; Ruefenacht, D.A. [Division of Neuroradiology, HUG, Geneva (Switzerland)

    2002-07-01

    We present a rare case of intraorbital ophthalmic artery aneurysm found incidentally, together with a ruptured aneurysm of the tip of the basilar artery. The intraorbital aneurysm was asymptomatic, and no treatment was offered. Angiographic control was recommended to detect any progression. Treatment may be indicated for documented enlargement or significant mass effect of the aneurysm. (orig.)

  6. Intraorbital ophthalmic artery aneurysm associated with basilar tip saccular aneurysm

    International Nuclear Information System (INIS)

    We present a rare case of intraorbital ophthalmic artery aneurysm found incidentally, together with a ruptured aneurysm of the tip of the basilar artery. The intraorbital aneurysm was asymptomatic, and no treatment was offered. Angiographic control was recommended to detect any progression. Treatment may be indicated for documented enlargement or significant mass effect of the aneurysm. (orig.)

  7. Coiled tubing

    International Nuclear Information System (INIS)

    Oil and gas wells that flow on initial completion eventually reach a condition of liquid loading that kills the wells. This results form declining reservoir pressure, decreased gas volume (velocity), increased water production and other factors that cause liquids to accumulate at the bottom of the well and exert back pressure on the formation. This restricts or in some cases prevents fluid entry into the wellbore form the formation. Flowing production can be restored or increased by reducing surface backpressure, well bore stimulation, pressure maintenance or by installing a string of smaller diameter tubing. This paper reports on installation (hanging off) of a concentric string of coiled tubing inside existing production tubing which is an economically viable, safe, convenient and effective alterative for returning some of these liquid loaded )logged-up) wells to flowing status

  8. Balloon-assisted coiling through a 5-French system

    International Nuclear Information System (INIS)

    We present a catheter technique that utilizes a 5F system for the purpose of balloon-assisted coiling in the setting of intracranial aneurysms. A standard 5F short sheath is placed in the common femoral artery, and a 5F diagnostic catheter is placed through the sheath and used for selective vessel angiography. When endovascular intervention is pursued, the diagnostic catheter is placed in the appropriate vessel and systemic heparinization is ensured. Over an exchange length wire, the 5F vertebral catheter and 5F short sheath are exchanged for a 5F Shuttle (Cook) sheath. We then routinely place a 10, 14 or 18 microcatheter over an appropriately gauged microguidewire into the aneurysm. As needed, balloon catheters are then placed across the neck of the aneurysm for remodeling purposes. During the course of the procedure, control angiography is performed through the Shuttle sheath. Following the placement of coils, the microcatheter and balloon catheter are removed and a final biplane image is obtained via the 5F Shuttle sheath. This technique has been employed in 15 patients who required balloon-assisted coiling of an intracranial aneurysm. There were no technical difficulties or arterial access site complications from the procedures. Catheter mobility and torque were not affected, nor was the quality of our imaging. We conclude that this small-diameter system provides ample ''room'' for catheter placement and interventional treatment while reducing the known risks of postprocedural complications. Angiographic images remain excellent and are comparable to those obtained by larger catheters. (orig.)

  9. Cranio-orbital approach for complex aneurysmal surgery.

    LENUS (Irish Health Repository)

    Kelleher, M O

    2012-02-03

    Certain aneurysms of the anterior circulation continue to offer a technical challenge for safe exposure and clipping. The purpose of this paper was to describe the cranio-orbital approach for surgical clipping of complex aneurysms and to evaluate prospectively the associated complications of this approach. Prospective audit of all patients undergoing cranio-orbital approach for aneurysm surgery from 1997 to 2004 by the senior author. Twenty-five patients, eight male and 17 female, median age of 52 years, range 28-73. All patients had a standard pterional approach supplemented by an orbital osteotomy. In the 7-year period 367 patients underwent treatment for their aneurysms (169 clipped and 198 coiled). Of the 169 patients who were operated on, 29 had a skull base approach, of which 25 were cranio-orbital. The aneurysm location was as follows: 16 middle cerebral artery (MCA), three carotid bifurcation, four anterior communicating artery (ACOMM), one ophthalmic and one basilar. There were no approach-related complications. The cranio-orbital craniotomy can be a useful adjunct in the surgical treatment of giant or complex aneurysms. It offers the following advantages over a standard pterional approach: reduces operative distance; allows easy splitting of the sylvian fissure; and provides a wide arc of exposure with multiple working corridors.

  10. Modulation of elasticity in functionally distinct domains of the tropomyosin coiled-coil

    OpenAIRE

    Lakkaraju, Sirish Kaushik; Hwang, Wonmuk

    2009-01-01

    Alpha-helical coiled-coils are common protein structural motifs. Whereas vast information is available regarding their structure, folding, and stability, far less is known about their elastic properties, even though they play mechanical roles in many cases such as tropomyosin in muscle contraction or neck stalks of kinesin or myosin motor proteins. Using computer simulations, we characterized elastic properties of coiled-coils, either globally or locally. Global bending stiffness of standard ...

  11. Flow Diversion in Aneurysms Trial: the Design of the FIAT study

    OpenAIRE

    Raymond, J.; Darsaut, T.E.; Guilbert, F.; Weill, A.; Roy, D

    2011-01-01

    Intracranial aneurysms, particularly large and giant, fusiform or recurrent aneurysms are increasingly treated with flow diverters (FDs), a recently introduced and approved neurovascular device. While some rare cases may not be treated any other way, in most patients a more conventional, conservative, or validated approach such as coiling, parent vessel occlusion, or surgical clipping exists. Only a randomized clinical trial can answer the question of which treatment option leads to better pa...

  12. Designing Stable Antiparallel Coiled Coil Dimers

    Institute of Scientific and Technical Information of China (English)

    曾宪纲; 周海梦

    2001-01-01

    The history of antiparallel coiled coil dimer design is briefly reviewed and the main principles governing the successful designs are explained. They include analysis of the inter-subunit electrostatic repulsion for determining partners for dimerization and of the buried polar interaction for determining the relative orientation of the partners. A theory is proposed to explain the lack of antiparallel coiled coil homodimers in nature.

  13. The coiled coils of cohesin are conserved in animals, but not in yeast.

    Directory of Open Access Journals (Sweden)

    Glenn E White

    Full Text Available BACKGROUND: The SMC proteins are involved in DNA repair, chromosome condensation, and sister chromatid cohesion throughout Eukaryota. Long, anti-parallel coiled coils are a prominent feature of SMC proteins, and are thought to serve as spacer rods to provide an elongated structure and to separate domains. We reported recently that the coiled coils of mammalian condensin (SMC2/4 showed moderate sequence divergence (approximately 10-15% consistent with their functioning as spacer rods. The coiled coils of mammalian cohesins (SMC1/3, however, were very highly constrained, with amino acid sequence divergence typically <0.5%. These coiled coils are among the most highly conserved mammalian proteins, suggesting that they make extensive contacts over their entire surface. METHODOLOGY/PRINCIPAL FINDINGS: Here, we broaden our initial analysis of condensin and cohesin to include additional vertebrate and invertebrate organisms and multiple species of yeast. We found that the coiled coils of SMC1/3 are highly constrained in Drosophila and other insects, and more generally across all animal species. However, in yeast they are no more constrained than the coils of SMC2/4 and Ndc80/Nuf2p, suggesting that they are serving primarily as spacer rods. CONCLUSIONS/SIGNIFICANCE: SMC1/3 functions for sister chromatid cohesion in all species. Since its coiled coils apparently serve only as spacer rods in yeast, it is likely that this is sufficient for sister chromatid cohesion in all species. This suggests an additional function in animals that constrains the sequence of the coiled coils. Several recent studies have demonstrated that cohesin has a role in gene expression in post-mitotic neurons of Drosophila, and other animal cells. Some variants of human Cornelia de Lange Syndrome involve mutations in human SMC1/3. We suggest that the role of cohesin in gene expression may involve intimate contact of the coiled coils of SMC1/3, and impose the constraint on sequence

  14. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... screened. In fact, patients who have a family history of aneurysm, men who are smoking over the age of 55 should be screened for aneurysms. And the way to screen is with a simple ultrasound. But sometimes a ...

  15. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available Aortic Aneurysm Repair May 7, 2009 Good afternoon. Welcome to the Baptist Cardiac and Vascular Institute here in Miami. My name ... our live webcast. Today we’re going to repair an abdominal aortic aneurysm using a technology called ...

  16. Role of {sup 123}I-IMP SPET in the early diagnosis of borderline chronic hydrocephalus after aneurysmal subarachnoid haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Ohkuma, Hiroki; Tanaka, Masahiko; Suzuki, Shigeharu [Dept. of Neurosurgery, Hirosaki University School of Medicine, Hirosaki (Japan); Kondoh, Izumi [Dept. of Rehabilitation Medicine, Institute of Brain Science, Hirosaki University School of Medicine, Hirosaki (Japan)

    2000-05-01

    Chronic hydrocephalus after aneurysmal subarachnoid haemorrhage (SAH) is easily diagnosed in most cases. However, the diagnosis is sometimes difficult in borderline cases, in which (a) pathognomonic clinical deterioration due to hydrocephalus is masked by the neurological deficits caused in the acute stage of SAH and (b) ventricular enlargement is not so marked on CT scan. The purpose of this study was to investigate whether or not iodine-123 labelled N-isopropyl-p-iodoamphetamine ({sup 123}I-IMP) single-photon emission tomography (SPET) is of value for the early diagnosis of borderline chronic hydrocephalus after SAH. Fifteen patients who met the criteria of borderline chronic hydrocephalus were selected for the study, and underwent a shunt operation. The patients were divided into a shunt-effective group and a shunt-ineffective group according to neurological improvement after the shunt operation. {sup 123}I-IMP SPET was performed in the acute stage of SAH, within 1 week before the shunt operation, and 2 weeks after the shunt operation. Regional cerebral blood flow was estimated by the {sup 123}I-IMP autoradiographic method. Pre-shunting periventricular low-perfusion areas showed statistically significant differences between the two groups (P<0.05). In the shunt-effective group, periventricular low-perfusion areas on pre-shunting SPET were significantly enlarged compared with those in the acute stage of SAH (P<0.05), and they were significantly reduced after the shunt operation (P<0.05). In the shunt-ineffective group, periventricular low-perfusion areas showed no significant changes during the course. These results suggest that periventricular low-perfusion areas enlarge in the early stage of chronic hydrocephalus after SAH, and that {sup 123}I-IMP SPET can be used for both the early diagnosis of borderline chronic hydrocephalus after SAH and the prediction of shunt effectiveness. (orig.)

  17. Role of endorectal coil magnetic resonance imaging in local staging of rectal cancer: Experience from a single center

    Directory of Open Access Journals (Sweden)

    Rayees Ahmad Dar

    2013-01-01

    Full Text Available Purpose: In order to obtain an improvement in preoperative staging accuracy for rectal cancer, new imaging modalities are now under investigation. The purpose of our study was to evaluate the accuracy of endorectal coil magnetic resonance imaging (ECMRI in the preoperative local staging of rectal cancer and correlation with intraoperative and histopathologic staging of retrieved specimen with respect to depth of tumor invasion and lymph node metastasis. Materials and Methods: The study was a prospective one and included 38 patients with biopsy proved rectal cancer. ECMRI studies were performed on a 1.5 Tesla MR unit using a standard endorectal coil. All patients underwent surgery and a comparative evaluation of ECMRI and surgical and pathological staging was done. Accuracy, sensitivity, specificity, and positive and negative predictive value (PPV and NPV were assessed. Results: The diagnostic accuracy of ECMRI for T1/T2 tumors was 90%; for T3 and T4 tumors accuracy was 100% each. For perirectal lymph node metastasis, the diagnostic accuracy of ECMRI was 83.3%. Conclusion: ECMRI is a reliable radiologic tool for local (T staging of rectal cancer and has excellent diagnostic accuracy, sensitivity, and specificity. ECMRI is also useful in detecting perirectal lymph node metastasis, but accuracy is not as good as that for T staging.

  18. Endovascular Therapeutic Occlusion of the Posterior Cerebral Artery: An Option for Ruptured Giant Aneurysm in a Child.

    Science.gov (United States)

    Demartini, Zeferino; Matos, Luiz Afonso Dias; Dos Santos, Marcio Luis Tostes; Cardoso-Demartini, Adriane de Andre

    2016-01-01

    The incidence of intracranial aneurysms in the pediatric population is low, and surgical clipping remains a good long-term treatment option. However, posterior circulation aneurysms are even more complex to manage in children than in adults. We report a case of a giant aneurysm of the posterior cerebral artery in a 10-year-old boy presenting with subarachnoid hemorrhage. Endovascular treatment with platinum coils was performed with total occlusion of the aneurysm and the affected arterial segment without complications. The patient achieved good recovery, and a late control angiogram confirmed exclusion of the aneurysm. Occurrence of special features of cerebral aneurysm in children, in comparison to adults, is also described. Parent artery sacrifice is an effective therapeutic option, but long-term follow-up is necessary to avoid recurrence and rebleeding. PMID:26974558

  19. Spontaneous resolution of a flow-related ophthalmic-segment aneurysm after treatment of anterior cranial fossa dural arteriovenous fistula

    Directory of Open Access Journals (Sweden)

    Kevin Reinard

    2014-01-01

    Full Text Available Background: The natural history of proximal, feeding-artery aneurysms after successful obliteration of high-grade, anterior cranial fossa dural arteriovenous fistulas (dAVFs has not been well documented. Case Description: A 52-year-old Caucasian male presented with an unruptured anterior cranial fossa (dAVF and an associated aneurysm. Cerebral angiography revealed a large, contralateral, carotid-ophthalmic segment aneurysm, enlarged feeding ophthalmic arteries, as well as cortical venous drainage. Successful surgical obliteration of the dAVF was undertaken to eliminate the risk of hemorrhage. Conclusion: The carotid-ophthalmic aneurysm regressed significantly after surgical obliteration of the dAVF and a follow-up, planned coiling procedure to address the carotid-ophthalmic aneurysm was abandoned. This represents the first reported case of a near complete, spontaneous resolution of an unruptured carotid-ophthalmic aneurysm associated with a high-grade anterior cranial fossa dAVF.

  20. Abciximab in the treatment of acute in-stent thrombosis in patient with intracranial aneurysm

    International Nuclear Information System (INIS)

    A case of endovascular therapy via embolization of aneurysm in patient with SAH is performed selective brain angiography and find 3 aneurysms. The first is in right segment M1-M2 with diameter 5 mm, the second with wide neck is in supraclinoid portion of right internal carotid artery and the third in left M1-M2 segment. One month after embolization of ruptured aneurysm with coils BALT (Montmorency, France) and previous anticoagulation therapy was applied Leo stent (SALT) intraluminal in left internal carotid artery. Developed acute instent thrombosis recanalized with intraarterial use of abciximab. (authors)

  1. Aortoiliac aneurysm with arteriocaval fistula treated by a bifurcated endovascular stent-graft

    International Nuclear Information System (INIS)

    A 71-year-old patient with high-output cardiac failure was found to have an aneurysmal distal aorta with evidence of an arteriocaval fistula on ultrasound scanning. CT demonstrated an aneurysm of the distal aorta and right common iliac artery and an intraarterial digital subtraction angiogram confirmed an arteriocaval fistula. In view of the patient's cardiac failure and general condition an endovascular stent was considered. The right internal iliac artery was occluded with Tungsten coils prior to the insertion of a bifurcated stent-graft. This resulted in total occlusion of the aneurysm and obliteration of the arteriocaval fistula. To our knolwedge such a case has not been previously reported.

  2. Aortoiliac Aneurysm with Arteriocaval Fistula Treated by a Bifurcated Endovascular Stent-Graft

    International Nuclear Information System (INIS)

    A 71-year-old patient with high-output cardiac failure was found to have an aneurysmal distal aorta with evidence of an arteriocaval fistula on ultrasound scanning. CT demonstrated an aneurysm of the distal aorta and right common iliac artery and an intraarterial digital subtraction angiogram confirmed an arteriocaval fistula. In view of the patient's cardiac failure and general condition an endovascular stent was considered. The right internal iliac artery was occluded with Tungsten coils prior to the insertion of a bifurcated stent-graft. This resulted in total occlusion of the aneurysm and obliteration of the arteriocaval fistula. To our knowledge such a case has not been previously reported

  3. Minimum Inductance Optimal Design for the Gradient Coil

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    In MRI (Magnetic Resonance Imaging), a crucial role of gradient coils is to image organism, meanwhile the inductance of the coils determines the speed of imaging. So it is of great importance to optimize designs of the gradient coils. The target field approach is an effective method to design the gradient coils. Having applied this method and performing many numerical tests, we achieved the designs of the x-、y-、z- gradient coils , with the linearity of the fields generated by the coils in a sphere of radius 0.30 m less than 5%, in which the inductance and resistance of the coils also meet the requirements.

  4. Critical evaluation of in silico methods for prediction of coiled-coil domains in proteins.

    Science.gov (United States)

    Li, Chen; Ching Han Chang, Catherine; Nagel, Jeremy; Porebski, Benjamin T; Hayashida, Morihiro; Akutsu, Tatsuya; Song, Jiangning; Buckle, Ashley M

    2016-03-01

    Coiled-coils refer to a bundle of helices coiled together like strands of a rope. It has been estimated that nearly 3% of protein-encoding regions of genes harbour coiled-coil domains (CCDs). Experimental studies have confirmed that CCDs play a fundamental role in subcellular infrastructure and controlling trafficking of eukaryotic cells. Given the importance of coiled-coils, multiple bioinformatics tools have been developed to facilitate the systematic and high-throughput prediction of CCDs in proteins. In this article, we review and compare 12 sequence-based bioinformatics approaches and tools for coiled-coil prediction. These approaches can be categorized into two classes: coiled-coil detection and coiled-coil oligomeric state prediction. We evaluated and compared these methods in terms of their input/output, algorithm, prediction performance, validation methods and software utility. All the independent testing data sets are available at http://lightning.med.monash.edu/coiledcoil/. In addition, we conducted a case study of nine human polyglutamine (PolyQ) disease-related proteins and predicted CCDs and oligomeric states using various predictors. Prediction results for CCDs were highly variable among different predictors. Only two peptides from two proteins were confirmed to be CCDs by majority voting. Both domains were predicted to form dimeric coiled-coils using oligomeric state prediction. We anticipate that this comprehensive analysis will be an insightful resource for structural biologists with limited prior experience in bioinformatics tools, and for bioinformaticians who are interested in designing novel approaches for coiled-coil and its oligomeric state prediction. PMID:26177815

  5. Epidemiology and genetics of intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Caranci, F., E-mail: ferdinandocaranci@libero.it [Unit of Neuroradiology, Department of Diagnostic Radiology and Radiotherapy, Federico II University, Naples (Italy); Briganti, F., E-mail: frabriga@unina.it [Unit of Neuroradiology, Department of Diagnostic Radiology and Radiotherapy, Federico II University, Naples (Italy); Cirillo, L.; Leonardi, M. [Neuroradiology service, Bellaria Hospital, Bologna (Italy); Muto, M., E-mail: mutomar@tiscali.it [Neuroradiology Service Cardarelli Hospital Naples (Italy)

    2013-10-01

    Intracranial aneurysms are acquired lesions (5–10% of the population), a fraction of which rupture leading to subarachnoid hemorrhage with devastating consequences. Until now, the exact etiology of intracranial aneurysms formation remains unclear. The low incidence of subarachnoid hemorrhage in comparison with the prevalence of unruptured IAs suggests that the vast majority of intracranial aneurysms do not rupture and that identifying those at highest risk is important in defining the optimal management. The most important factors predicting rupture are aneurysm size and site. In addition to ambiental factors (smoking, excessive alcohol consumption and hypertension), epidemiological studies have demonstrated a familiar influence contributing to the pathogenesis of intracranial aneurysms, with increased frequency in first- and second-degree relatives of people with subarachnoid hemorrhage. In comparison to sporadic aneurysms, familial aneurysms tend to be larger, more often located at the middle cerebral artery, and more likely to be multiple. Other than familiar occurrence, there are several heritable conditions associated with intracranial aneurysm formation, including autosomal dominant polycystic kidney disease, neurofibromatosis type I, Marfan syndrome, multiple endocrine neoplasia type I, pseudoxanthoma elasticum, hereditary hemorrhagic telangiectasia, and Ehlers-Danlos syndrome type II and IV. The familial occurrence and the association with heritable conditions indicate that genetic factors may play a role in the development of intracranial aneurysms. Genome-wide linkage studies in families and sib pairs with intracranial aneurysms have identified several loci on chromosomes showing suggestive evidence of linkage, particularly on chromosomes 1p34.3–p36.13, 7q11, 19q13.3, and Xp22. For the loci on 1p34.3–p36.13 and 7q11, a moderate positive association with positional candidate genes has been demonstrated (perlecan gene, elastin gene, collagen type 1 A2

  6. Epidemiology and genetics of intracranial aneurysms

    International Nuclear Information System (INIS)

    Intracranial aneurysms are acquired lesions (5–10% of the population), a fraction of which rupture leading to subarachnoid hemorrhage with devastating consequences. Until now, the exact etiology of intracranial aneurysms formation remains unclear. The low incidence of subarachnoid hemorrhage in comparison with the prevalence of unruptured IAs suggests that the vast majority of intracranial aneurysms do not rupture and that identifying those at highest risk is important in defining the optimal management. The most important factors predicting rupture are aneurysm size and site. In addition to ambiental factors (smoking, excessive alcohol consumption and hypertension), epidemiological studies have demonstrated a familiar influence contributing to the pathogenesis of intracranial aneurysms, with increased frequency in first- and second-degree relatives of people with subarachnoid hemorrhage. In comparison to sporadic aneurysms, familial aneurysms tend to be larger, more often located at the middle cerebral artery, and more likely to be multiple. Other than familiar occurrence, there are several heritable conditions associated with intracranial aneurysm formation, including autosomal dominant polycystic kidney disease, neurofibromatosis type I, Marfan syndrome, multiple endocrine neoplasia type I, pseudoxanthoma elasticum, hereditary hemorrhagic telangiectasia, and Ehlers-Danlos syndrome type II and IV. The familial occurrence and the association with heritable conditions indicate that genetic factors may play a role in the development of intracranial aneurysms. Genome-wide linkage studies in families and sib pairs with intracranial aneurysms have identified several loci on chromosomes showing suggestive evidence of linkage, particularly on chromosomes 1p34.3–p36.13, 7q11, 19q13.3, and Xp22. For the loci on 1p34.3–p36.13 and 7q11, a moderate positive association with positional candidate genes has been demonstrated (perlecan gene, elastin gene, collagen type 1 A2

  7. [ANEURYSMAL TYPE RENAL ARTERIOVENOUS FISTULA WITH GIANT VENOUS ANEURYSM, MIMICKING RENAL CELL CARCINOMA: A CASE REPORT].

    Science.gov (United States)

    Nagumo, Yoshiyuki; Komori, Hiroka; Rii, Jyunryo; Ochi, Atsuhiko; Suzuki, Koichiro; Shiga, Naoki; Ota, Tomonori

    2015-04-01

    A 39-year-old man was referred to our clinic for a 7 cm tumor in the right kidney, found by simple CT scan. It was suspected as renal cell carcinoma accompanying tumor emboli in the inferior vena cava by enhanced CT scan. For further evaluation of the tumor emboli, color Doppler ultrasound and enhanced MRI was performed. They showed a large cystic lesion with high velocity turbulent flow and flow voids in T2-weighted imaging, it seemed as giant venous aneurysm of the right renal vein. Subsequently, angiography revealed aneurysmal type renal arteriovenous fistula (AVF), transarterial embolization (TAE) of the arterial feeder with coils was performed on the same day. After 6 months from embolization, there was no recurrences or reinterventions. Color Doppler ultrasound and MRI are beneficial in distinguishing vascular disease from neoplastic disease which may sometimes mimick in other diagnostic imaging studies. In addition TAE seems to be an effective treatment for the AVF. PMID:26415363

  8. Placement of a Neuroform2 stent into the parent vessel by navigating it along the inner wall of the aneurysm sac. A technical case report

    International Nuclear Information System (INIS)

    The Neuroform2 stent has proven to be a very helpful device in the stent-assisted coiling of wide-necked cerebral aneurysms particularly because of its high navigability. We describe the case of a 33-year-old man with a ruptured anterior cerebral artery aneurysm that was successfully embolized and a wide-necked unruptured middle cerebral artery (MCA) aneurysm that required stent-assisted coiling. All attempts to catheterize the parietal branch of the MCA in order to deploy the stent were unsuccessful since various guidewires followed a circular path inside the aneurysm sac. Based on our experience on the flexibility of the Neuroform2 stent, and since the aneurysm was unruptured, we decided to follow the circular path of the wire inside the aneurysm with the stent microcatheter. The stent navigated easily into the parietal branch where it was correctly deployed and the aneurysm was uneventfully embolized. This maneuver might pose the risk of aneurysm puncture in ruptured aneurysms but might prove helpful in unruptured wide-necked calcified or partially thrombosed aneurysms. (orig.)

  9. No advantage of time-of-flight magnetic resonance angiography at 3 Tesla compared to 1.5 Tesla in the follow-up after endovascular treatment of cerebral aneurysms

    OpenAIRE

    Buhk, Jan-Hendrik; Kallenberg, Kai; Mohr, Alexander; Dechent, Peter; Knauth, Michael

    2008-01-01

    Introduction: Long-term follow-up after coil embolization of intracranial aneurysms is mandatory to monitor coil compacting and aneurysm recurrence. Most centers perform one digital subtraction angiography (DSA) on follow-up continuing with time-of-flight magnetic resonance angiography (TOFMRA). This study explores the diagnostic value of TOFMRA at 1.5 T versus 3 T compared to DSA. Materials and methods: In 18 patients with 20 aneurysms treated with coil embolization, TOFMRA at 1.5 and 3 T we...

  10. Treatment of Endovascular Coil and Stent Migration Using the Merci Retriever: Report of Three Cases

    Directory of Open Access Journals (Sweden)

    David K. Kung

    2012-01-01

    Full Text Available Background. Coil and stent migration is a potentially catastrophic complication in endovascular neurosurgery, which may lead to cerebral thromboembolism. Techniques for removing migrated coil and stent are not well established. Methods and Results. We present three cases in which coil or stent migration occurred during endovascular embolization of a cerebral aneurysm. The Merci Retrievers were used successfully in all cases to remove the displaced foreign bodies. Technical details are described. Conclusion. The Merci Retriever device can be utilized successfully for removal of migrated coils and stents in endovascular neurosurgery.

  11. Endotension - a cause of failure in endovascular repair of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    The phenomenon of aortic aneurysm enlargement after endovascular repair without detectable endoleak is called 'endotension'. It is caused by persistent pressurization within the excluded aneurysm sac and may cause subsequent rupture of the aneurysm. We undertake a review of current knowledge about causes, significance and treatment of endotension as a failure in endovascular aortic aneurysm repair. The goal of endovascular abdominal aortic aneurysm repair is to prevent aneurysm ruptures by excluding the aneurysms from the aortic circulation. AAA (Abdominal Aortic Aneurysm) after EVAR (Endovascular Aneurysm Repair) can enlarge even in the absence of detectable endoleak because of persistent pressurization within the excluded aneurysm. There are many theories about the mechanism of pressure transmission into the excluded aneurismal sac. Some laboratory and clinical research shows that endotension can be connected with attachment side failure, graft fabrics or aneurysm sac geometry. Pressure transmission by the thrombus, poor outflow, osmotic effect or ultrafiltration are the other possible mechanisms causing this phenomenon. Maximal diameter measurement by CT is considered to be the best management method in patients after EVAR. However, lack of aneurysm sac shrinkage observed in some cases does not mean the presence of endotension. The role of pulsatility inside the excluded aneurysm sac remains unclear. Several possible concepts of endotension treatment have been discussed, including both open surgical convention and nonoperative approach. The absence of endoleak after endovascular repair not always means that there is no pressurization within the aneurysm. Success of endovascular repair can be evaluated indirectly by observation of changes in the diameter of the aneurysm sac after EVAR. Thus, it is essential to follow up patients after endovascular repair in order to detect any late complications including endotension

  12. The Role of Quench-back in the Passive Quench Protection of Uncoupled Solenoids in Series with and without Coil Sub-division

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Xing Long; Green, Michael A; Wang, Li; Wu, Hong; Pan, Heng

    2010-10-15

    This paper is the final paper in a series of papers that discusses passive quench protection for high inductance solenoid magnets. This report describes how passive quench protection system may be applied to superconducting magnets that are connected in series but not inductively coupled. Previous papers have discussed the role of magnet sub-division and quench back from a conductive mandrel in reducing the hot-spot temperature and the peak coil voltages to ground. When magnets are connected in series, quench-back from a conductive mandrel can cause other magnets in a string to quench even without inductive coupling between magnets. The magnet mandrels must be well coupled to the magnet circuit that is being quenched. When magnet circuit sub-division is employed to reduce the voltages-to-ground within magnets, the resistance across the subdivision becomes the most important factor in the successful quenching of the magnet string.

  13. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... And one of the things that I’m learning from this movie as we looking at these ... screened. In fact, patients who have a family history of aneurysm, men who are smoking over the ...

  14. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... with such holes in the groin, this really offers the patient a tremendous advantage over having his ... a thousand aneurysms with this. So we can offer patients a very, very good integrated care with ...

  15. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... moving inside in the aneurysm sack with the spine projected in the background. So how long have ... have a much more rapid recovery than open surgery. What do you think about that, Ignacio, compared ...

  16. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... years, and his aneurysm has now grown to 5.4 centimeters. And this is actually an important ... balloon is trying to iron out the attachment. 5 So right now we have the first half ...

  17. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... been following in the institute for the past three years, and his aneurysm has now grown to ... may get for other reasons, but we use three-dimensional reconstruction and we can reconstruct all the ...

  18. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... the age of 65. It’s most common in males. There is an increasing number, due to the ... The risk factors for abdominal aortic aneurysms are males over 60, hardening of the arteries, which is ...

  19. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... wall will actually thin out. And the big risk here is that if this gets too big ... to the aging baby boomers. Next slide. The risk factors for abdominal aortic aneurysms are males over ...

  20. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... They carry oxygen and blood to various organs. These arteries have muscular walls, and when they get ... continue to expand, and they can rupture. And these aneurysms can occur in a lot of different ...

  1. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... this procedure. So let’s go back now and learn a little bit about abdominal aortic aneurysms. Great. ... And one of the things that I’m learning from this movie as we looking at these ...

  2. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... dye and also to do measurements using our computer techniques that are going on here. So what ... screened. In fact, patients who have a family history of aneurysm, men who are smoking over the ...

  3. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... to do now is begin to do the process of putting an endograft in, and I’m ... that we saw, actually thrombosis. So in the process of thrombosing or clotting off the aneurysm sack, ...

  4. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... to the aging baby boomers. Next slide. The risk factors for abdominal aortic aneurysms are males over 60, ... doing a good examination and also accessing for risk factors. So we have a very integrated team here, ...

  5. Popliteal vein aneurysm.

    Science.gov (United States)

    Falkowski, A; Poncyljusz, W; Zawierucha, D; Kuczmik, W

    2006-06-01

    The incidence of a popliteal vein aneurysm is extremely low. Two cases of this rare venous anomaly are described. The epidemiology, morphology, and diagnostic methods are discussed and the potentially dangerous complications and treatment methods are presented. PMID:16796307

  6. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... information is critical for us in terms of planning and guiding the procedure we’re going to ... be screened. In fact, patients who have a family history of aneurysm, men who are smoking over ...

  7. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... this is to prevent rupture and to prevent death from rupture. This area just underneath the renal ... Okay. Abdominal aortic aneurysms cause approximately 15,000 deaths in the United States each year. It affects ...

  8. Coincidence of an anterior cerebral artery aneurysm and a glioblastoma: case report and review of literature

    Directory of Open Access Journals (Sweden)

    Nguyen HS

    2015-11-01

    Full Text Available Ha Son Nguyen,1 Ninh Doan,1 Michael Gelsomino,1 Saman Shabani,1 Wade Mueller,1 Osama O Zaidat2 1Department of Neurosurgery, 2Department of Neurology, Medical College of Wisconsin, Milwaukee, WI, USA Background: The association between glioblastoma and intracranial aneurysm is rare. Treatment guidelines do not exist, and operative mortality and morbidity are significantly high. To our knowledge, no prior cases have employed endovascular therapy for the treatment of these intratumor intracranial aneurysms followed by tumor resection. Case presentation: A 74-year-old male, history of a left A2 aneurysm, presented after a motor vehicle accident at low speeds. Imaging was concerning for a possible traumatic brain contusion, an aneurysmal hemorrhage given history of left A2 aneurysm, or a hemorrhage from an underlying tumor given profound edema. The patient was discussed at the brain tumor board, where the plan was to address the aneurysm followed by resection of the mass versus close monitoring with subsequent imaging. The high risk of rehemorrhage, given the real possibility of an aneurysmal hemorrhage, motivated prompt treatment of the aneurysm. The patient was taken to the angiography suite; an anterosuperiorly projecting azygous A2 aneurysm, measuring 4.5 mm × 5.5 mm with a neck width at 3.5 mm and a small daughter sac, was completely obliterated with primary coiling. The following day, he underwent a left craniotomy along a forehead skin crease for mass excision. Final pathology revealed glioblastoma. The patient recovered well from both procedures, with a baseline neurological exam. The patient subsequently underwent hypofractionated radiation and temodar. Conclusion: To our knowledge, no prior cases have employed endovascular therapy for the treatment of these intracranial aneurysms. We emphasize that efforts to introduce less invasive elements may improve the overall outcomes in this rare patient population. Keywords: intracranial aneurysm

  9. Impact of stents and flow diverters on hemodynamics in idealized aneurysm models.

    Science.gov (United States)

    Seshadhri, Santhosh; Janiga, Gábor; Beuing, Oliver; Skalej, Martin; Thévenin, Dominique

    2011-07-01

    Cerebral aneurysms constitute a major medical challenge as treatment options are limited and often associated with high risks. Statistically, up to 3% of patients with a brain aneurysm may suffer from bleeding for each year of life. Eight percent of all strokes are caused by ruptured aneurysms. In order to prevent this rupture, endovascular stenting using so called flow diverters is increasingly being regarded as an alternative to the established coil occlusion method in minimally invasive treatment. Covering the neck of an aneurysm with a flow diverter has the potential to alter the hemodynamics in such a way as to induce thrombosis within the aneurysm sac, stopping its further growth, preventing its rupture and possibly leading to complete resorption. In the present study the influence of different flow diverters is quantified considering idealized patient configurations, with a spherical sidewall aneurysm placed on either a straight or a curved parent vessel. All important hemodynamic parameters (exchange flow rate, velocity, and wall shear stress) are determined in a quantitative and accurate manner using computational fluid dynamics when varying the key geometrical properties of the aneurysm. All simulations are carried out using an incompressible, Newtonian fluid with steady conditions. As a whole, 72 different cases have been considered in this systematic study. In this manner, it becomes possible to compare the efficiency of different stents and flow diverters as a function of wire density and thickness. The results show that the intra-aneurysmal flow velocity, wall shear stress, mean velocity, and vortex topology can be considerably modified thanks to insertion of a suitable implant. Intra-aneurysmal residence time is found to increase rapidly with decreasing stent porosity. Of the three different implants considered in this study, the one with the highest wire density shows the highest increase of intra-aneurysmal residence time for both the straight and

  10. Stability and specificity of heterodimer formation for the coiled-coil neck regions of the motor proteins Kif3A and Kif3B: the role of unstructured oppositely charged regions

    OpenAIRE

    Chana, M.S.; Tripet, B.P.; Mant, C. T.; Hodges, R.

    2005-01-01

    We investigated the folding, stability, and specificity of dimerization of the neck regions of the kinesin-like proteins Kif3A (residues 356–416) and Kif3B (residues 351–411). We showed that the complementary charged regions found in the hinge regions (which directly follow the neck regions) of these proteins do not adopt any secondary structure in solution. We then explored the ability of the complementary charged regions to specify heterodimer formation for the neck region coiled-coils foun...

  11. Nursing experience in clinical endovascular treatment for renal artery aneurysms

    International Nuclear Information System (INIS)

    Objective: To discuss the standardized clinical nursing measures for patients receiving endovascular treatment of renal artery aneurysms. Methods: The clinical data of 9 patients with renal artery aneurysm, who were admitted to authors' hospital during the period from Jan. 2010 to Aug. 2011 and received endovascular treatment, were retrospectively analyzed. The related nursing points as well as the received endovascular. Results: A total of 9 cases with renal artery aneurysm were treated nursing measures were summarized. Results: A total of 9 cases with renal artery aneurysm were with interventional management, including embolization (n = 6), stent implantation (n = 2) and stent implantation together with coil embolization (n = 1). The mean hospitalization time was (10±2) days. Postoperative retention of urine was observed in one patient and postoperative retroperitoneal hemorrhage occurred in another patient. Neither nursing-related nor operation-related complications occurred. Conclusion: Standardized perioperative nursing care for patients with renal artery aneurysm can surely help enhance the patient's tolerance to the surgery, and effectively prevent the complications. (authors)

  12. Giant Serpentine Internal Carotid Artery Aneurysm: Endovascular Parent Artery Occlusion: A Pediatric Case Report

    OpenAIRE

    Prochazka, V.; Chmelova, J.; Cizek, V.; Skoloudik, D.; Hrbac, T.

    2007-01-01

    We report on a case of a 14-year-old boy with a giant serpentine aneurysm of the left internal carotid artery cavernous segment with symptoms of acute mass-effect cranial nerve dysfunction. After a balloon occlusion test of the collateral circulation, the patient underwent parent artery occlusion with platinum Guglielmi detachable coils and fibered coils. An optimal angiographic result and successful clinical outcome were achieved with resolution of IIIrd, IVth and Vlth cranial nerve ischemic...

  13. The Expanding Realm of Endovascular Neurosurgery: Flow Diversion for Cerebral Aneurysm Management

    Science.gov (United States)

    Krishna, Chandan; Sonig, Ashish; Natarajan, Sabareesh K.; Siddiqui, Adnan H.

    2014-01-01

    The worldwide prevalence of intracranial aneurysms is estimated to be between 5% and 10%, with some demographic variance. Subarachnoid hemorrhage secondary to ruptured intracranial aneurysm results in devastating neurological outcomes, leaving the majority of victims dead or disabled. Surgical clipping of intracranial aneurysms remained the definitive mode of treatment until Guglielmi detachable coils were introduced in the 1990s. This revolutionary innovation led to the recognition of neurointervention/neuroendovascular surgery as a bona fide option for intracranial aneurysms. Constant evolution of endovascular devices and techniques supported by several prospective randomized trials has catapulted the endovascular treatment of intracranial aneurysms to its current status as the preferred treatment modality for most ruptured and unruptured intracranial aneurysms. We are slowly transitioning from the era of coils to the era of flow diverters. Flow-diversion technology and techniques have revolutionized the treatment of wide-necked, giant, and fusiform aneurysms, where the results of microsurgery or conventional neuroendovascular strategies have traditionally been dismal. Although the Pipeline™ Embolization Device (ev3-Covidien, Irvine, CA) is the only flow-diversion device approved by the Food and Drug Administration for use in the United States, others are commercially available in Europe and South America, including the Silk (Balt Extrusion, Montmorency, France), Flow-Redirection Endoluminal Device (FRED; MicroVention, Tustin, CA), Surpass (Stryker, Kalamazoo, MI), and p64 (Phenox, Bochum, Germany). Improvements in technology and operator experience and the encouraging results of clinical trials have led to broader acceptance for the use of these devices in cerebral aneurysm management. Continued innovation and refinement of endovascular devices and techniques will inevitably improve technical success rates, reduce procedure-related complications, and broaden

  14. CT evaluation of anastomotic aneurysms following vascular reconstructive procedures

    International Nuclear Information System (INIS)

    Despite improved surgical techniques, anastomotic aneurysms continue to complicate vascular reconstructive procedures. The role of CT in this condition has not been previously emphasized. Twenty-one patients with 31 anastomotic aneurysms following aortofemoral or aortoiliac graft placement were evaluated by CT and angiography and four by CT alone. CT contributed significant addiitional information affecting the surgical approach to the lesion in six patients. CT was superior in defining local complications, the longitudinal extent of the aneurysms, and in demonstrating mural thrombus, which occurred at 13 anastomoses. CT should be performed in conjunction with angiography in the evaluation of this condition

  15. Risk of Familial Intracranial Aneurysm

    OpenAIRE

    J Gordon Millichap; Millichap, John J.

    2014-01-01

    Investigators at University Medical Center Utrecht, Netherlands, studied the yield of long-term (up to 20 years) screening for intracranial aneurysms in individuals with a positive family history (2 or more first-degree relatives) of aneurysmal subarachnoid hemorrhage (aSAH) or unruptured intracranial aneurysm (1993-2013).

  16. Prediction of two month modified Rankin Scale with an ordinal prediction model in patients with aneurysmal subarachnoid haemorrhage

    OpenAIRE

    Sneade Mary; Yarnold Julia; Kerr Richard SC; Molyneux Andrew J; Lingsma Hester F; Risselada Roelof; Steyerberg Ewout W; Sturkenboom Miriam CJM

    2010-01-01

    Abstract Background Aneurysmal subarachnoid haemorrhage (aSAH) is a devastating event with a frequently disabling outcome. Our aim was to develop a prognostic model to predict an ordinal clinical outcome at two months in patients with aSAH. Methods We studied patients enrolled in the International Subarachnoid Aneurysm Trial (ISAT), a randomized multicentre trial to compare coiling and clipping in aSAH patients. Several models were explored to estimate a patient's outcome according to the mod...

  17. Prediction of two month modified Rankin Scale with an ordinal prediction model in patients with aneurysmal subarachnoid haemorrhage

    OpenAIRE

    Risselada, Roelof; Roozenbeek, Bob; Molyneux, Andrew; Kerr, R. S. C.; Yarnold, Julia; Sneade, Mary; Steyerberg, Ewout; Sturkenboom, Miriam

    2010-01-01

    textabstractBackground. Aneurysmal subarachnoid haemorrhage (aSAH) is a devastating event with a frequently disabling outcome. Our aim was to develop a prognostic model to predict an ordinal clinical outcome at two months in patients with aSAH. Methods. We studied patients enrolled in the International Subarachnoid Aneurysm Trial (ISAT), a randomized multicentre trial to compare coiling and clipping in aSAH patients. Several models were explored to estimate a patient's outcome according to th...

  18. Metachronous Bilateral Posterior Tibial Artery Aneurysms in Ehlers-Danlos Syndrome Type IV

    International Nuclear Information System (INIS)

    Ehlers-Danlos syndrome type IV is a life-threatening genetic connective tissue disorder. We report a 24-year-old woman with EDS-IV who presented with metachronous bilateral aneurysms/pseudoaneurysms of the posterior tibial arteries 15 months apart. Both were treated successfully with transarterial coil embolization from a distal posterior tibial approach.

  19. Haemostatic factors, atherosclerosis and risk of abdominal aortic aneurysm.

    Science.gov (United States)

    Lee, A J; Fowkes, F G; Lowe, G D; Rumley, A

    1996-10-01

    Abdominal aortic aneurysms have traditionally been thought to be a consequence of severe atherosclerosis of the arterial wall. To date, the role of haemostatic factors in aneurysmal disease has not been extensively researched. The aim of this study was to see if such factors were independently related to the occurrence of aortic aneurysm. Furthermore, were the associations maintained after taking into account the presence of underlying atherosclerotic disease? Using data from the Edinburgh Artery Study, a nested case-control design was used involving 40 cases of aortic aneurysm, each being matched to five controls by sex and within a 5-year age band. After adjustment for age and sex, both fibrinogen (P D-dimer (P aneurysm. Further adjustment for packyears, history of cardiovascular disease and the ankle brachial pressure index resulted in odds ratios of 1.51 (95% CI 1.05 to 2.16, P D-dimer. These associations probably arise as a consequence of fibrin deposition and turnover within the aneurysmal sac, although further prospective studies are needed before thrombotic factors can be used in the identification of a group who are at high risk of developing an abdominal aortic aneurysm. PMID:8958392

  20. The Effect of Hemodynamics on Cerebral Aneurysm Morphology

    Science.gov (United States)

    Metcalfe, Ralph; Mantha, Aishwarya; Karmonik, Christof; Strother, Charles

    2004-11-01

    One of the difficulties in applying principles of hemodynamics to the study of blood flow in aneurysms are the drastic variations in possible shape of both the aneurysms and the parent arteries in the region of interest. We have taken data from three para-opthalmic internal carotid artery aneurysms using 3D-digital subtraction angiography (3D-DSA) and performed CFD simulations of steady and unsteady flows through the three different cases using the same pressure gradients and pulsatile flow waveforms (based on the Ku model for flow through the Carotid bifurcation). We have found that the total pressure differential within the aneurysms is consistent with the direction of flow, and that the dynamic pressure gradient within the aneurysm is very small compared with the static pressure variations. Wall shear stresses were highest near regions of sharp arterial curvature, but always remained low inside the aneurysm. These results suggest a more complex role for hemodynamics in aneurysm generation, growth and rupture.

  1. Aneurysmal Subarachnoid Hemorrhage and Neuroinflammation: A Comprehensive Review

    Science.gov (United States)

    Lucke-Wold, Brandon P.; Logsdon, Aric F.; Manoranjan, Branavan; Turner, Ryan C.; McConnell, Evan; Vates, George Edward; Huber, Jason D.; Rosen, Charles L.; Simard, J. Marc

    2016-01-01

    Aneurysmal subarachnoid hemorrhage (SAH) can lead to devastating outcomes including vasospasm, cognitive decline, and even death. Currently, treatment options are limited for this potentially life threatening injury. Recent evidence suggests that neuroinflammation plays a critical role in injury expansion and brain damage. Red blood cell breakdown products can lead to the release of inflammatory cytokines that trigger vasospasm and tissue injury. Preclinical models have been used successfully to improve understanding about neuroinflammation following aneurysmal rupture. The focus of this review is to provide an overview of how neuroinflammation relates to secondary outcomes such as vasospasm after aneurysmal rupture and to critically discuss pharmaceutical agents that warrant further investigation for the treatment of subarachnoid hemorrhage. We provide a concise overview of the neuroinflammatory pathways that are upregulated following aneurysmal rupture and how these pathways correlate to long-term outcomes. Treatment of aneurysm rupture is limited and few pharmaceutical drugs are available. Through improved understanding of biochemical mechanisms of injury, novel treatment solutions are being developed that target neuroinflammation. In the final sections of this review, we highlight a few of these novel treatment approaches and emphasize why targeting neuroinflammation following aneurysmal subarachnoid hemorrhage may improve patient care. We encourage ongoing research into the pathophysiology of aneurysmal subarachnoid hemorrhage, especially in regards to neuroinflammatory cascades and the translation to randomized clinical trials. PMID:27049383

  2. From GWAS to the clinic: risk factors for intracranial aneurysms

    OpenAIRE

    Ruigrok, Ynte M.; Rinkel, Gabriel JE

    2010-01-01

    Subarachnoid hemorrhage (SAH) from a ruptured intracranial aneurysm is a devastating subset of stroke, occurring in relatively young people (mean age around 50 years) of whom around a third die within the initial weeks after the bleed. Environmental and genetic risk factors both have a role in SAH. A recent genome-wide association study of intracranial aneurysms in Finnish, Dutch and Japanese cohorts totaling 5,891 cases and 14,181 controls identified three new loci strongly associated with i...

  3. Cloning, overexpression, purification and crystallization of the CRN12 coiled-coil domain from Leishmania donovani

    International Nuclear Information System (INIS)

    The L. donovani coronin CRN12 coiled-coil domain (5.8 kDa) was cloned, overexpressed and purified to homogeneity. Crystals of recombinant L. donovani coronin CRN12 coiled-coil domain were grown by vapour diffusion using a hanging-drop setup. Leishmania donovani coronin CRN12 is an actin-binding protein which consists of two domains: an N-terminal WD repeat domain and a C-terminal coiled-coil domain. The coiled-coil domain is 53 residues in length. Helix–helix interactions in general and coiled coils in particular are ubiquitous in the structure of proteins and play a significant role in the association among proteins, including supramolecular assemblies and transmembrane receptors that mediate cellular signalling, transport and actin dynamics. The L. donovani coronin CRN12 coiled-coil domain (5.8 kDa) was cloned, overexpressed, purified to homogeneity and the N-terminal 6×His tag was successfully removed by thrombin cleavage. Crystals of recombinant L. donovani coronin CRN12 coiled-coil domain were grown by vapour diffusion using a hanging-drop setup. Diffraction-quality crystals were obtained and data extending to 2.46 Å resolution were collected at 100 K on BM14, ESRF, Grenoble, France. The crystal belonged to the monoclinic space group C2, with unit-cell parameters a = 118.0, b = 50.6, c = 46.0 Å, β = 111.0°. Matthews coefficient (VM) calculations suggested the presence of 4–6 molecules in the asymmetric unit, corresponding to a solvent content of ∼33–55%, and are consistent with self-rotation function calculations

  4. Morphological and hemodynamic analysis of mirror posterior communicating artery aneurysms.

    Directory of Open Access Journals (Sweden)

    Jinyu Xu

    Full Text Available BACKGROUND AND PURPOSE: Hemodynamic factors are commonly believed to play an important role in the pathogenesis, progression, and rupture of cerebral aneurysms. In this study, we aimed to identify significant hemodynamic and morphological parameters that discriminate intracranial aneurysm rupture status using 3-dimensional-angiography and computational fluid dynamics technology. MATERIALS AND METHODS: 3D-DSA was performed in 8 patients with mirror posterior communicating artery aneurysms (Pcom-MANs. Each pair was divided into ruptured and unruptured groups. Five morphological and three hemodynamic parameters were evaluated for significance with respect to rupture. RESULTS: The normalized mean wall shear stress (WSS of the aneurysm sac in the ruptured group was significantly lower than that in the unruptured group (0.52±0.20 versus 0.81±0.21, P = .012. The percentage of the low WSS area in the ruptured group was higher than that in the unruptured group (4.11±4.66% versus 0.02±0.06%, P = .018. The AR was 1.04±0.21 in the ruptured group, which was significantly higher than 0.70±0.17 in the unruptured group (P = .012. By contrast, parameters that had no significant differences between the two groups were OSI (P = .674, aneurysm size (P = .327, size ratio (P = .779, vessel angle (P = 1.000 and aneurysm inclination angle (P = 1.000. CONCLUSIONS: Pcom-MANs may be a useful disease model to investigate possible causes of aneurysm rupture. The ruptured aneurysms manifested lower WSS, higher percentage of low WSS area, and higher AR, compared with the unruptured one. And hemodynamics is as important as morphology in discriminating aneurysm rupture status.

  5. Influence of Selective Biochemical and Morphological Agents on Natural History of Aneurysm of Abdominal Aorta Development.

    Science.gov (United States)

    Wołoszko, Tomasz; Skórski, Maciej; Kwasiborski, Przemysław; Kmin, Ewelina; Gałązka, Zbigniew; Pogorzelski, Ryszard

    2016-01-01

    BACKGROUND The development of abdominal aortic aneurysm (AAA) is probably influenced by many factors. The role of some of these factors, such as intraluminal thrombus (ILT) or cystatin C serum levels, remains controversial. Proving their influence could have therapeutic implications for some patients with AAA. Associations between the rate of increase in diameter of an aneurysm and ILT, as well as other factors, including biochemical factors (C-Reactive Protein - CRP, cystatin C), age, sex, and comorbidities, could predict disease progression in individual patients. MATERIAL AND METHODS Seventy patients with small AAA were included into the study. The patients were followed using ultrasound and CT imaging. We evaluated aneurysm dimensions and aneurysm wall thickness, as well as ILT and its dimensions, aneurysm wall morphology, CRP, and cystatin C. RESULTS We observed significant growth of AAA and thinning of aneurysmal wall. Aneurysms over 4 cm grew significantly faster in the second year of observation. ILT grew together with AAA size. Age, sex, smoking, dyslipidemias, or controlled arterial hypertension had no influence on aneurysm progression rate. Changes in serum of CRP concentration did not reach statistical significance, but cystatin C levels did. CONCLUSIONS Presence and size of ILT, wall thickness, and cystatin C levels may be considered in prediction of AAA progression. ILT might exert a protective influence on the risk of aneurysm rupture. However, larger aneurysms containing larger thrombi grow faster and their walls undergo more rapid degradation, which in turn increases the risk of rupture. This matter requires further studies. PMID:26859744

  6. Verminous aneurysm caused by filaria.

    Science.gov (United States)

    Toledo, F V; de Araújo, A P; da Cunha, A M; Sidow, J R; Pavão, S G; de Araújo, E D

    1983-06-01

    Aneurysms caused by atherosclerosis are relatively frequent, as a consequence of the high incidence of this degenerative disease of the arteries. Other types of aneurysm, for example, those of infectious etiology, are more uncommon. Bacterias and fungi are able to cause aneurysms in several parts of the arterial tree. Stengel et al (1943), in a review of world literature described 217 cases of mycotic aneurysms. The Stedman's Medical Dictionary refers to a special type of aneurysm observed in horses, caused by intra-vascular migration of a worm, the Strongylus vulgaris. It has been named verminous aneurysm and generally involves the mesenteric arteries. We haven't found in medical literature any similar observations refering to human cases. The purpose of this paper is to describe a case of aneurysm the etiology of which we have imputed to the filaria (Wuchereria bancrofti). This case was observed in Marcilio Dias Naval Hospital, Rio de Janeiro, Brazil. PMID:6346961

  7. Echocardiographic evidence of innate aortopathy in the human intracranial aneurysm.

    Directory of Open Access Journals (Sweden)

    Yong-Won Shin

    Full Text Available BACKGROUND: Intracranial aneurysm (IA is significantly more prevalent in patients with coarctation of the aorta or bicuspid aortic valve than in the general population, suggesting a common pathophysiology connecting IA and aortopathy. Here, we analyzed echocardiographic aortic root dimension (ARD in patients with IA to confirm this possibility. METHODS: From January 2008 to December 2010, 260 consecutive patients with IA who were admitted to our institution for coil embolization or for acute stroke management and who also underwent echocardiography were enrolled. We hypothesized that patients with large, ruptured, or multiple IAs are more likely to harbor co-prevalent aortopathy as measured by ARD compared to patients with small, isolated, unruptured IAs. Eccentric group was defined as patients aged <55 years with at least one ruptured aneurysm, an aneurysm ≥7 mm in size, or multiple aneurysms; the remainder was classified into a non-eccentric group. Clinical, angiographic, and echocardiographic findings of the two groups were compared. RESULTS: ARD was significantly larger in the eccentric group than in the non-eccentric group (P = 0.049, and the difference was confirmed by multivariable analysis (P = 0.02. Subgroup analysis of patients aged <55 years showed similar result for ARD (P = 0.03, whereas hypertension was more associated with the non-eccentric group (P = 0.01. In addition, height was inversely related to aneurysm size after adjustment for age, sex, weight, ARD, smoking status, and number of aneurysms (P = 0.004. CONCLUSIONS: A certain group of IA patients share a common intrinsic wall defect with aortopathy. Shared neural crest cell origin may give rise to this phenomenon.

  8. Comparative study of novel endovascular treatment techniques for intracranial aneurysms

    Science.gov (United States)

    Cantón, Gádor; Lasheras, Juan C.; Levy, David I.; Sparks, Steven R.

    2002-11-01

    Intracranial aneurysms are life-threatening vascular lesions, which are potentially treatable to avoid the consequences of their rupture. Current treatments, either surgical or endovascular, are all guided to reduce the hemodynamic forces acting on the aneurysm wall in an effort to minimize the risk of rupture. Surgical clipping is still the most used technique to treat this type of aneurysm but there is a continued demand for less invasive approaches. This has led to the development of several endovascular techniques. We report here a comparative study of the reduction in the hemodynamic stresses and the modification of the flow in the parent vessel resulting from the use of three different techniques. The first one consists of endosaccular packing with platinum coils (GDC, Target Therapeutics), which is already widely used but its long-term efficacy has not yet been determined. The second one consists of the embolization of the aneurismal sac with Onyx, a polymer which hardens when in contact with the blood (being developed by Micro Therapeutics, Inc.). The third one involves the packing of the sac with hydrocoils, platinum wires coated with a gel which quickly hydrates when in contact with blood (developed by MicroVention). A Digital Particle Image Velocimetry (DPIV) system is used to measure in vitro the velocity field inside a model of an ACOM aneurysm (an aneurysm forming in the anterior communicating artery). Physiological accurate pulsatile flow conditions are input to the arterial model through a programmable pump. The measurements show that although all treatment techniques lead to a reduction in both normal and tangential shear stresses on the aneurismal sac, each one of them also leads to different modifications of the flow in the parent vessel which may have consequences related to potential for clotting. Comparison of the untreated aneurysm with the above three treated cases also showed that the characteristics of the wall shear stresses on the parent

  9. Cine-CT diagnosis of coronary artery aneurysms in patients with Kawasaki

    International Nuclear Information System (INIS)

    Coronary artery aneurysms (CAA) are the most serious late sequelae of Kawasaki disease, and periodic screening examinations are necessary. Two-dimensional (2D) echocardiography represents the standard screening method; however, visualization of the distal coronary arteries is often limited. This report documents the complimentary role of cine-CT with 2D echocardiography in the evaluation of CAA induced by Kawasaki disease. Six pediatric patients with coronary aneurysms were evaluated with both 2D echocardiography and cine-CT. Cine-CT detected ten of 11 lesions. The one misdiagnosed CAA was one of the two contiguous aneurysms. Owing to intersection thickness, these two discrete aneurysms were interpreted as a solitary aneurysm. Cine-CT detected one CAA not initially visualized on echocardiography. Cine-CT is effective and complementary to 2D echocardigraphy as a noninvasive method for the evaluation of coronary artery aneurysms occurring as sequelae of Kawasaki disease

  10. What You Should Know about Cerebral Aneurysms

    Science.gov (United States)

    ... T. Quiz 5 Things to Know About Stroke What You Should Know About Cerebral Aneurysms Updated:Jun ... Damage Treatments Click image to view an animation What is a cerebral aneurysm? An aneurysm is a ...

  11. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... past three years, and his aneurysm has now grown to 5.4 centimeters. And this is actually ... that looks like kind of railroad tracks going up and down, that’s the catheter that we’re ...

  12. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... for all of you listening, you can ask online. Just click the “Ask a question” button, and ... aneurysm. Please feel free to ask any questions online. Just click “Ask a question,” and they’ll ...

  13. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... racquet-like device whether or not there is flow in this sack after we replace in aneurysm. ... space age. That’s fine. Don’t go too high. Pull it down a little bit. Pull that ...

  14. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... an interventional radiologist. That’s a specialty many people haven’t heard of, but that’s a specialty that ... in that patient’s abdominal sack. Now remember we haven’t treated his aneurysm. We’re sort of ...

  15. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... to repair an abdominal aortic aneurysm using a technology called an “endograft,” which is sometimes called the “ ... separate area, and it’s because of this small technology that allows you to do this. Exactly. So ...

  16. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... an aneurysm, it’s important that you ask your doctor about your options. As I said, about 80 percent of the patients we treat end up -- 80 or 90 percent these days, end up being good candidates for this type of therapy. We would encourage you to seek the least ...

  17. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... an abdominal aortic aneurysm. Normally this procedure takes us about 45 minutes to an hour of doctor work time, which is, I think, a fairly quick procedure to replace a major life-threatening problem in the patient’s abdomen. So you can see ...

  18. Aortic Aneurysm Repair

    Medline Plus

    Full Text Available ... microchip that acts a little bit like a cell phone technology. We’ll show you how that works. But this is the device that we’re going to put in that space between the endograft and the patient to the wall of the aneurysm. So in that space where ...

  19. The JET divertor coil

    International Nuclear Information System (INIS)

    The divertor coil is mounted inside the Jet vacuum vessel and is able to carry 1 MA turns. It is of conventional construction - water cooled copper, epoxy glass insulation -and is contained in a thin stainless steel case. The coil has to be assembled, insulated and encased inside the Jet vacuum vessel. A description of the coil is given, together with technical information (including mechanical effects on the vacuum vessel), an outline of the manufacture process and a time schedule. (author)

  20. Leisure and social participation in patients 4–10 years after aneurysmal subarachnoid haemorrhage

    NARCIS (Netherlands)

    Buunk, Anne M.; Groen, Rob J. M.; Veenstra, Wencke S.; Spikman, Jacoba M.

    2015-01-01

    Objective: To investigate the long-term resumption of leisure and social activities in patients with aneurysmal subarachnoid haemorrhage (aSAH) and to determine the role of executive dysfunction and aneurysms in anterior brain regions in particular. Method: Leisure and social functioning of 200 pati

  1. [A case of peduncular hallucination after aneurysmal subarachnoid hemorrhage].

    Science.gov (United States)

    Nakagawa, N; Akai, F; Niiyama, K; Asai, T; Tanada, M

    1999-01-01

    We reported a case of peduncular hallucination after aneurysmal subarachnoid hemorrhage (SAH). The patient underwent endovascular embolization of an intracranial aneurysm using the Guglielmi detachable coils (GDCs) 9 days after SAH. On the 11th day, she reported visual hallucination: a maggot was on the ceiling, or a soldier who wore green clothes was standing by a locker. The hallucination was vivid, well-formed and associated with insomnia, suggesting peduncular hallucination. A computed tomographic (CT) scan revealed small infarctions of right frontal lobe, which were not responsible for the visual hallucination. Hyperdynamic therapy relieved the visual hallucination 23 days after SAH. It was conceivable that vasospasm was the cause of the infarction and visual hallucination. Only 4 cases with peduncular hallucination after SAH were reported in conjunction with vasospasm. The symptom may be concealed by disturbance of consciousness. Visual hallucination should be considered as a sign of cerebral vasospasm, and an appropriate treatment should be done at right time. PMID:10065463

  2. Inflammation and intracranial aneurysms: mechanisms of initiation, growth, and rupture

    Directory of Open Access Journals (Sweden)

    Peter S Amenta

    2015-06-01

    Full Text Available Outcomes following aneurysmal subarachnoid hemorrhage remain poor in many patients, despite advances in microsurgical and endovascular management. Consequently, considerable effort has been placed in determining the mechanisms of aneurysm formation, growth, and rupture. Various environmental and genetic factors are implicated as key components in the aneurysm pathogenesis. Currently, sufficient evidence exists to incriminate the inflammatory response as the common pathway leading to aneurysm generation and rupture. Central to this model is the interaction between the vessel wall and inflammatory cells. Dysfunction of the endothelium and vascular smooth muscle cells (VSMCs promotes a chronic pathological inflammatory response that progressively weakens the vessel wall. We review the literature pertaining to the cellular and chemical mechanisms of inflammation that contribute to aneurysm development. Hemodynamic stress and alterations in blood flow are discussed regarding their role in promoting chronic inflammation. Endothelial cell and VSMC dysfunction are examined concerning vascular remodeling. The contribution of inflammatory cytokines, especially tumor necrosis factor-α is illustrated. Inflammatory cell infiltration, particularly macrophage-mediated deterioration of vascular integrity, is reviewed. We discuss the inflammation as a means to determine aneurysms at greatest risk of rupture. Finally, future therapeutic implications of pharmacologic modulation of the inflammation are discussed.

  3. CT features of mycotic aneurysms

    International Nuclear Information System (INIS)

    To describe CT features of mycotic aneurysms. We have retrospectively checked 10 patients diagnosed with mycotic aneurysm. Three revealed previously treated arteriosclerotic aneurysms, one was diabetic and had undergone a reno pancreatic transplant,and another presented advanced HIV infection. They al presented fever syndrome and eight exhibited leucocytosis. Mycotic aneurysm diagnosis was made by means of CT findings, clinical examination and positive hemo culture in all cases. Anatomopathological findings were available as confirmation for all four surgically treated patients. The CT scan was performed during arterial phase with spiral acquisition, without contrast and with endo venous administration of a contrast medium. Saccular aneurysms were found in seven patients (double aneurysms in the case of two), with seven of these being abdominal aneurysms (one retrocrural aortic,three infra renal aortic, and three iliac arteries) and two thoracic (aortic arch). In all three remaining patients, there was a pre-existing arteriosclerotic aneurysm (fusiform) and only incipient changes were observed in the adjacent fat. Perianeurysmatic soft-tissue was was noted in eight cases. Only two patients presented signs of tear (peri aneurysm hematoma and/or with contrast extravasation). In three cases, the calcium ring was disrupted. In two patients, absences were observed in other locations. In none of the cases was there gas in the aneurysm wall. Mycotic aneurysm is a rate entity, but must be considered in the evaluation of septic patients since it demands early diagnosis and treatment. In such patients, a CT finding of saccular aneurysm with adjacent soft-tissue mass, and associated with a positive hemo culture, is highly suggestive of this pathology. (Author) 9 refs

  4. Management of Unruptured Intracranial Aneurysms.

    Science.gov (United States)

    Nasr, Deena M; Brown, Robert D

    2016-09-01

    Unruptured intracranial aneurysms (UIA) occur in approximately 2-3 % of the population. Most of these lesions are incidentally found, asymptomatic and typically carry a benign course. Although the risk of aneurysmal subarachnoid hemorrhage is low, this complication can result in significant morbidity and mortality, making assessment of this risk the cornerstone of UIA management. This article reviews important factors to consider when managing unruptured intracranial aneurysms including patient demographics, comorbidities, family history, symptom status, and aneurysm characteristics. It also addresses screening, monitoring, medical management and current surgical and endovascular therapies. PMID:27443382

  5. Application of Microstructure Engineering in Steel Coil Cooling Process

    Institute of Scientific and Technical Information of China (English)

    LIU Zheng-dong; D Q Jin; I V Samarasekera; J K Brimacombe

    2005-01-01

    The coil cooling and its role in a hot strip mill were reviewed.A mathematical model was developed to describe and analyze the thermal history and its impact on precipitation phenomena during coil cooling for plain car bon,HSLA-V and HSLA-Nb steels.The predicted result of the thermal model was compared with that measured from industrial coil.The effect of cooling condition and coil dimension on the thermal history and final mechanical properties of the steel strip was examined.The coiling temperature and cooling rate have crucial influence on the precipitation strengthening.

  6. Transretroperitoneal CT-guided Embolization of Growing Internal Iliac Artery Aneurysm after Repair of Abdominal Aortic Aneurysm: A Transretroperitoneal Approach with Intramuscular Lidocaine Injection Technique

    International Nuclear Information System (INIS)

    This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up of 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome

  7. Transretroperitoneal CT-guided Embolization of Growing Internal Iliac Artery Aneurysm after Repair of Abdominal Aortic Aneurysm: A Transretroperitoneal Approach with Intramuscular Lidocaine Injection Technique

    Energy Technology Data Exchange (ETDEWEB)

    Park, Joon Young, E-mail: pjy1331@hanmail.net; Kim, Shin Jung, E-mail: witdd2@hanmail.net; Kim, Hyoung Ook, E-mail: chaos821209@hanmail.net [Chonnam National University Hospital, Department of Radiology (Korea, Republic of); Kim, Yong Tae, E-mail: mono-111@hanmail.net [Chonnam National University Hwasun Hospital, Department of Radiology (Korea, Republic of); Lim, Nam Yeol, E-mail: apleseed@hanmail.net; Kim, Jae Kyu, E-mail: kjkrad@jnu.ac.kr [Chonnam National University Hospital, Department of Radiology (Korea, Republic of); Chung, Sang Young, E-mail: sycpvts@jnu.ac.kr; Choi, Soo Jin Na, E-mail: choisjn@jnu.ac.kr; Lee, Ho Kyun, E-mail: mhaha@hanmail.net [Chonnam National University Hospital, Department of Surgery (Korea, Republic of)

    2015-02-15

    This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up of 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome.

  8. Compact stellarator coils

    International Nuclear Information System (INIS)

    Experimental devices to study the physics of high-beta (β>∼4%), low aspect ratio (A<∼4.5) stellarator plasmas require coils that will produce plasmas satisfying a set of physics goals, provide experimental flexibility, and be practical to construct. In the course of designing a flexible coil set for the National Compact Stellarator Experiment, we have made several innovations that may be useful in future stellarator design efforts. These include: the use of Singular Value Decomposition methods for obtaining families of smooth current potentials on distant coil winding surfaces from which low current density solutions may be identified; the use of a Control Matrix Method for identifying which few of the many detailed elements of the stellarator boundary must be targeted if a coil set is to provide fields to control the essential physics of the plasma; the use of Genetic Algorithms for choosing an optimal set of discrete coils from a continuum of potential contours; the evaluation of alternate coil topologies for balancing the tradeoff between physics objective and engineering constraints; the development of a new coil optimization code for designing modular coils, and the identification of a 'natural' basis for describing current sheet distributions. (author)

  9. Active internal corrector coils

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, P.A.; Cottingham, J.; Dahl, P.; Fernow, R.; Garber, M.; Ghosh, A.; Goodzeit, C.; Greene, A.; Hahn, H.; Herrera, J.

    1986-01-01

    Trim or corrector coils to correct main magnet field errors and provide higher multipole fields for beam optics purposes are a standard feature of superconducting magnet accelerator systems. This paper describes some of the design and construction features of powered internal trim coils and a sampling of the test results obtained.

  10. Active internal corrector coils

    International Nuclear Information System (INIS)

    Trim or corrector coils to correct main magnet field errors and provide higher multipole fields for beam optics purposes are a standard feature of superconducting magnet accelerator systems. Some of the design and construction features of powered internal trim coils and a sampling of the test results obtained are described

  11. A fusiform aneurysm of a persistent trigeminal artery variant: case report and literature review.

    Science.gov (United States)

    Yang, Zhigang; Liu, Jianmin; Zhao, Wenyuan; Xu, Yi; Hong, Bo; Huang, Qinghai; He, Shike

    2010-04-01

    A 48-year-old man suffered from spontaneous subarachnoid hemorrhage. Emergent right internal carotid angiography showed the presence of a persistent trigeminal artery (PTA) variant with a fusiform aneurysm on its proximal segment where it branched from the internal carotid artery. This artery supplied the territory of the anterior inferior cerebellar artery. After consideration of the adequacy of the cerebellar circulation without this anomalous artery, intraluminal occlusion of the aneurysm together with the PTA variant was performed using detachable coils. The patient recovered uneventfully without any neurologic deficits. PMID:19690795

  12. Endovascular treatment of splenic artery aneurysms

    International Nuclear Information System (INIS)

    Purpose. To assess the feasibility and effectiveness of endovascular treatment of splenic artery aneurysm (SAAs). Materials and methods. Between May 2000 and June 2003 we treated 11 true SAAs in 9 patients (7 females and 2 males; mean age 58 years), 8 saccular and 3 fusiform, 4 located at the middle tract of the splenic artery, 5 at the distal tract and 2 intra-parenchymal. The diagnosis was performed with colour-Doppler ultrasound and/or CT-angiography; 7 patients were symptomless, 1 had left hypochondriac pain, and 1 had acute abdomen caused by a ruptured SAA. Four SAAs were treated by micro coil embolisation of the aneurysmal sac with preservation of splenic artery patency; in 2 cases this was associated with transcatheter injection of N-butyl-2-cyanoacrylate. Four cases were treated by endovascular ligature, with sectoral spleen ischaemia. One ruptured SAA received emergency treatment with splenic artery cyanoacrylate embolisation. Two intra-parenchymal SAAs were excluded, one by cyanoacrylate embolisation of the afferent artery and the other by transcatheter thrombin injection in the aneurysmal sac. Results. Technical success was observed in all cases (in 10/11 at the end of the procedure; in 1/11 at CT performed 3 days after the procedure). The follow-up (mean 18 months; range 6-36) was performed by colour-Doppler ultrasound and/or CT-angiography 3, 6 and 12 months after the procedure and subsequently once a year; the complete exclusion of the aneurysms was confirmed in 11/11 cases. The complications were: 4 cases of mild pleuritis; fever and left hypochondriac pain 1 day after the procedure (in the same 4 patients and in one other case); 5 cases of sectorial spleen ischaemia and 1 case of diffuse spleen infarction with partial revascularization by collateral vessels. No alteration of the levels of pancreatic enzymes was found; a transitory increase in platelet count occurred only in the patient with diffuse spleen infarction. Conclusions. Using different

  13. Abdominal aortic aneurysm surgery

    DEFF Research Database (Denmark)

    Gefke, K; Schroeder, T V; Thisted, B; Olsen, P S; Perko, M J; Agerskov, Kim; Røder, O; Lorentzen, Jørgen Ewald

    1994-01-01

    The goal of this study was to identify patients who need longer care in the ICU (more than 48 hours) following abdominal aortic aneurysm (AAA) surgery and to evaluate the influence of perioperative complications on short- and long-term survival and quality of life. AAA surgery was performed in 55......, 78% stated that their quality of life had improved or was unchanged after surgery and had resumed working. These data justify a therapeutically aggressive approach, including ICU therapy following AAA surgery, despite failure of one or more organ systems.......The goal of this study was to identify patients who need longer care in the ICU (more than 48 hours) following abdominal aortic aneurysm (AAA) surgery and to evaluate the influence of perioperative complications on short- and long-term survival and quality of life. AAA surgery was performed in 553...

  14. Intracranial aneurysm and sildenafil.

    Science.gov (United States)

    Adiga, Avinash; Edriss, Hawa; Nugent, Kenneth

    2016-04-01

    Sildenafil is one of the most commonly used drugs for the treatment of erectile dysfunction. To date, we found five reported cases of intracerebral bleeding and two reported cases of subarachnoid hemorrhage related to sildenafil use. We report a 49-year-old hypertensive and diabetic patient who presented with acute pulmonary edema and loss of consciousness following ingestion of 100 mg of sildenafil prior to sexual intercourse. He was not previously aware of the presence of an aneurysm and had no family history of it. Computed tomography of his head revealed a subarachnoid hemorrhage due to rupture of a saccular aneurysm with subsequent repeat hemorrhage within a few hours of presentation. A sudden increase in blood pressure led to pulmonary edema. Studies have shown that sildenafil acts on phosphodiesterase-1, -2 and -5 receptors and leads to a secondary increase in intracerebral circulation and vasodilatory effects, leading to sympathetic overactivity which increases the risk for intracranial bleeding. PMID:27034561

  15. Development of a static bioactive stent prototype and dynamic aneurysm-on-a-chip(TM) model for the treatment of aneurysms

    Science.gov (United States)

    Reece, Lisa M.

    Aneurysms are pockets of blood that collect outside blood vessel walls forming dilatations and leaving arterial walls very prone to rupture. Current treatments include: (1) clipping, and (2) coil embolization, including stent-assisted coiling. While these procedures can be effective, it would be advantageous to design a biologically active stent, modified with magnetic stent coatings, allowing cells to be manipulated to heal the arterial lining. Further, velocity, pressure, and wall shear stresses aid in the disease development of aneurysmal growth, but the shear force mechanisms effecting wound closure is elusive. Due to these factors, there is a definite need to cultivate a new stent device that will aid in healing an aneurysm in situ. To this end, a static bioactive stent device was synthesized. Additionally, to study aneurysm pathogenesis, a lab-on-a-chip device (a dynamic stent device) is the key to discovering the underlying mechanisms of these lesions. A first step to the reality of a true bioactive stent involves the study of cells that can be tested against the biomaterials that constitute the stent itself. The second step is to test particles/cells in a microfluidic environment. Therefore, biocompatability data was collected against PDMS, bacterial nanocellulose (BNC), and magnetic bacterial nanocellulose (MBNC). Preliminary static bioactive stents were synthesized whereby BNC was grown to cover standard nitinol stents. In an offshoot of the original research, a two-dimensional microfluidic model, the Aneurysm-on-a-ChipTM (AOC), was the logical answer to study particle flow within an aneurysm "sac" - this was the dynamic bioactive stent device. The AOC apparatus can track particles/cells when it is coupled to a particle image velocimetry software (PIV) package. The AOC fluid flow was visualized using standard microscopy techniques with commercial microparticles/cells. Movies were taken during fluid flow experiments and PIV was utilized to monitor.

  16. Intracranial-to-intracranial bypass for posterior inferior cerebellar artery aneurysms: options, technical challenges, and results in 35 patients.

    Science.gov (United States)

    Abla, Adib A; McDougall, Cameron M; Breshears, Jonathan D; Lawton, Michael T

    2016-05-01

    -quarter of all PICA aneurysms treated microsurgically at our center requiring bypass without a single EC-IC bypass. The selection of PICA bypass is almost algorithmic: trapped aneurysms at the PICA origin or p1 segment are revascularized with a PICA-PICA bypass, with PICA reimplantation as an alternative; trapped p2 segment aneurysms are reanastomosed, bypassed in situ, or reimplanted; distal p3 segment aneurysms are reanastomosed or revascularized with a PICA-PICA bypass; and aneurysms of the p4 segment that are too distal for PICA-PICA bypass are reanastomosed. Interposition grafts are reserved for when these 3 primary options are unsuitable. A constructive approach that preserves the PICA with direct clipping or replaces flow with a bypass when sacrificed should remain an alternative to deconstructive PICA occlusion and endovascular coiling when complete aneurysm occlusion is unlikely. PMID:26566199

  17. Evaluation of stent visibility by flat panel detector CT in patients treated for intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Clarencon, Frederic [Groupe Hospitalier Pitie-Salpetriere, Paris (France); Pitie-Salpetriere Hospital, Department of Neuroradiology, Paris (France); Piotin, Michel; Pistocchi, Silvia; Blanc, Raphael [Fondation A. de Rothschild, Paris (France); Babic, Drazenko [Philips Healthcare, Best (Netherlands)

    2012-10-15

    This study aimed to evaluate the visibility of stents using high-resolution computed tomography (CT) acquisitions acquired with flat panel detector (XperCT, Allura series, Philips Healthcare, The Netherlands) for endovascular treatment of intracranial aneurysms. On a 24-month period, 48 patients endovascularly treated by coiling and stenting (59 stents) for intracranial aneurysms were explored by flat panel detector CT technique. A sequence of 620 2D images was acquired over an angle of 240 using a 1,024 x 1,024 pixel matrix detector within a 48-cm field of view. The images were retrospectively analyzed independently by two neuroradiologists. Evaluation criteria were percentage of visualization of the stents and stent deployment (kinking or unsatisfactory deployment of the stent). Evaluation of the stent was feasible for all the patients. Stent visibility by XperCT was overall estimated at 76% of the stent length. Difficulties to analyze the stents were related to coil artifacts but not to packing density or aneurysm location. Stent length visualization was higher when the acquisition was performed before additional coiling (P < 0.0001). Mild kinking/misdeployment was noticed in 22% of the cases. XperCT technique provides multiplanar and 3D reconstructions that allows for a satisfying visualization of intracranial stents. This CT-like acquisition should be performed after the stent deployment and before coiling, in order to obtain better stent visualization. (orig.)

  18. Post-Treatment Hemodynamics of a Basilar Aneurysm and Bifurcation

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, J; Hartman, J; Rodriguez, J; Maitland, D

    2008-01-16

    Aneurysm re-growth and rupture can sometimes unexpectedly occur following treatment procedures that were initially considered to be successful at the time of treatment and post-operative angiography. In some cases, this can be attributed to surgical clip slippage or endovascular coil compaction. However, there are other cases in which the treatment devices function properly. In these instances, the subsequent complications are due to other factors, perhaps one of which is the post-treatment hemodynamic stress. To investigate whether or not a treatment procedure can subject the parent artery to harmful hemodynamic stresses, computational fluid dynamics simulations are performed on a patient-specific basilar aneurysm and bifurcation before and after a virtual endovascular treatment. The simulations demonstrate that the treatment procedure produces a substantial increase in the wall shear stress. Analysis of the post-treatment flow field indicates that the increase in wall shear stress is due to the impingement of the basilar artery flow upon the aneurysm filling material and to the close proximity of a vortex tube to the artery wall. Calculation of the time-averaged wall shear stress shows that there is a region of the artery exposed to a level of wall shear stress that can cause severe damage to endothelial cells. The results of this study demonstrate that it is possible for a treatment procedure, which successfully excludes the aneurysm from the vascular system and leaves no aneurysm neck remnant, to elevate the hemodynamic stresses to levels that are injurious to the immediately adjacent vessel wall.

  19. Idiopathic aneurysms of distal cerebellar arteries: endovascular treatment after rupture

    International Nuclear Information System (INIS)

    Idiopathic ruptured aneurysms of distal cerebellar arteries (DCAAs) are rare, and their endovascular therapy (EVT) has as yet not been extensively reported. They are usually assumed to result from local arterial wall disruption rather than infection, unlike distal supratentorial artery aneurysms. This study was performed to audit their frequency, potential aetiology and results of EVT. Using strict inclusion criteria and a database of 1715 EVT patients, we identified ten idiopathic ruptured DCAAs (0.6%) over a 13-year period (1993-2006). The series comprised six males and four females with mean age of 64 years and solitary aneurysms located on posterior inferior cerebellar artery (five patients), anterior inferior cerebellar artery (three patients) and superior cerebellar artery (two patients). Nine aneurysms were fusiform and were treated by endovascular parent artery occlusion, and one was saccular and treated by endosaccular packing. Endovascular therapy was performed with coils in seven cases, n-butyl-2-cyanoacrylate (NBCA) in two cases and with both in one case. Primary EVT was successful in eight patients. One patient died following a procedure-related re-bleeding and one patient required re-treatment after failed endosaccular packing. Nine patients made good or excellent clinical recoveries (modified Rankin Scale 2 or less). Focal cerebellar infarctions were seen on computed tomography images after EVT in three patients, only one of whom was symptomatic with transient dysmetria, which resolved completely during follow up. No aneurysm recanalisation was detected on late follow-up imaging up to 24 months. Ruptured DCAAs are rare. The majority are fusiform in shape and their aetiology remains uncertain. Endovascular treatment is feasible and effective. It usually requires parent artery occlusion. (orig.)

  20. [Subarachnoid hemorrhage without aneurysm].

    Science.gov (United States)

    Müller-Forell, W; Welschehold, S; Köhler, J; Schicketanz, K H

    2002-11-01

    The rupture and bleeding of intracranial aneurysms is the most common cause of a spontaneous, non-traumatic subarachnoid hemorrhage (SAH). In up to 20% of these patients, no aneurysm is found, but the prognosis of these patients is known to be better than in those with aneurysms. The retrospective evaluation of the initial CT- and angiographic findings of 773 patients with spontaneous SAH, who underwent (up to three) 4-vessel DSA, brought a percentage of 12.4% with negative angiography. We found the favourable prognosis of these patients with negative angiography not only to be dependent from the distribution of the hemorrhage, with preference to perimesencephalic pattern, but the initial clinical state. 85% of our patients, who presented with perimesencephalic blood pattern and even 80% of those patients with additional intraventricular hemorrhage but the good clinical condition of Hunt-Hess I/II were discharged without neurological deficits. We recommend the obligatory 4-vessel catheter-angiography (DSA) in all patients with spontaneous SAH, independent of the blood pattern on initial CT, and one control in the presence of other than perimesencephalic subarachnoid hemorrhage, CTA might be reserved for additional controls. PMID:12458439

  1. Visualization of novel microstents in patients with unruptured intracranial aneurysms with contrast-enhanced flat panel detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Poncyljusz, Wojciech, E-mail: wponcyl@poczta.onet.pl [Departament of Interventional Radiology, Pomeranian Medical University, Neurointerventional Cath Lab MSW Hospital, Al. Powst. Wielkopolskich 72, 70-111 Szczecin (Poland); Zwarzany, Łukasz, E-mail: zwarzany@gmail.com [Departament of Interventional Radiology, Pomeranian Medical University, Neurointerventional Cath Lab MSW Hospital, Al. Powst. Wielkopolskich 72, 70-111 Szczecin (Poland); Safranow, Krzysztof, E-mail: chrissaf@mp.pl [Department of Biochemistry and Chemistry, Pomeranian Medical University, Al. Powst. Wielkopolskich 72, 70-111 Szczecin (Poland)

    2015-07-15

    Highlights: • We examine the feasibility of FPDCT for visualizing intracranial microstents. • Stent deployment and its apposition to the vessel wall are easily assessable. • Coil streaking artifacts hamper the assessment of stent visibility. - Abstract: Objectives: The aim of our study was to evaluate the feasibility of contrast-enhanced flat panel detector CT (FPDCT) for visualizing the novel microstents implanted in patients with unruptured wide-necked intracranial aneurysms. Methods: Forty-four cases of patients who underwent stent assisted coiling at our department were retrospectively analyzed. In each case, FPDCT images were performed after stent and coils deployment and then assessed in the terms of stent struts and all radiopaque markers and tantalum strands visibility separately using a 3-grade scale (1 – inadequate, 2 – good, 3 – excellent). Results: Stent struts visibility was assessed to be inadequate for evaluation in all cases. All radiopaque markers and tantalum strands visibility was excellent in 61.4% and good in 38.6% of cases. We observed 4 (9.09%) cases of incomplete stent opening. Treated aneurysm size <10 mm was an independent predictor of excellent stent all radiopaque markers and tantalum strands visibility (ρ = 0.014). Conclusions: Contrast-enhanced FPDCT is feasible for visualizing stents implanted in patients with intracranial aneurysms as it gives precise visualization of the relationships between the stent tantalum strands and the vessel wall. Stents used in the treatment of aneurysms ≥10 mm in size are worse visualized because of the coil streaking artifacts.

  2. Our experience with endovascular treatment of brain aneurysms and AVMs

    International Nuclear Information System (INIS)

    Full text: Endovascular treatment of brain aneurysm and AVM's is minimally invasive method performed to block or stop blood flow into the pathological vessels and to prevent main complications. In these procedures are used different technical devices like platinum coils, stents, occlusion balloons, liquid embolizants and etc. The last 15 years endovascular technic shown significant progress and development in treatment of brain vascular malformations. Endovascular treatment in Bulgaria has been performed since 2007 under supervision of foreign specialists. We present our experience and will show our cases from the last year - methods, strategy and the follow up.

  3. Giant superior mesenteric artery aneurysm

    OpenAIRE

    Temiz, Ahmet; Bostan, Mehmet; Şatıroğlu, Ömer; Çetin, Mustafa; Bozkurt, Engin

    2011-01-01

    Aneurysm of the superior mesenteric artery (SMA) is a rare condition and most of them are symptomatic. Gradu­ally increasing abdominal pain, intestinal ischemic symp­toms and rupture are the most common symptoms. We herein report a giant SMA aneurysm detected in a patient with complaint of abdominal discomfort.

  4. True aneurysm of brachial artery.

    Science.gov (United States)

    Hudorović, Narcis; Lovričević, Ivo; Franjić, Dario Bjorn; Brkić, Petar; Tomas, Davor

    2010-10-01

    True upper extremity peripheral artery aneurysms are a rarely encountered arterial disorder. Following computer-tomography angiographic (CT-a) imaging examination, true saccular aneurysm, originating from the left brachial artery was diagnosed in the 77-year-old female without history of trauma. The aneurysm was resected by surgical intervention, and primary repair of the brachial artery was performed by interposition of a part of great saphenous vein harvested from the left groin and creation of two end-to-end anastomoses between interposition graft and previously resected part of brachial artery. No complication was observed during the follow-up. Surgical intervention for upper extremity aneurysms should be initiated without delay. Factors combined with minimal morbidity associated with repair suggest that surgical repair should be performed routinely for true upper extremity arterial aneurysms. PMID:20865459

  5. EDITORIAL: Selected papers from the 16th Workshop on MHD Stability Control: Optimizing and Understanding the Role of Coils for Mode Control Selected papers from the 16th Workshop on MHD Stability Control: Optimizing and Understanding the Role of Coils for Mode Control

    Science.gov (United States)

    La Haye, Rob

    2012-09-01

    The Magnetohydrodynamic (MHD) Control Workshop with the theme 'Optimizing and Understanding the Role of Coils for Mode Control' was held at General Atomics (20-22 November 2011) following the 2011 APS-DPP Annual Meeting in Salt Lake City, Utah (14-18 November). This was the 16th in the annual series and was organized jointly by Columbia University, General Atomics, Princeton Plasma Physics Laboratory, and the University of Wisconsin-Madison. Program committee participation included representatives from the EU and Japan along with other US laboratory and university institutions. This workshop highlighted the role of applied non-axisymmetric magnetic fields from both internal and external coils for control of MHD stability to achieve high performance fusion plasmas. The application of 3D magnetic field offers control of important elements of equilibrium, stability, and transport. The use of active 3D fields to stabilize global instabilities and to correct magnetic field errors is an established tool for achieving high beta configurations. 3D fields also affect transport and plasma momentum, and are shown to be important for the control of edge localized modes (ELMs), resistive wall modes, and optimized stellarator configurations. The format was similar to previous workshops, including 13 invited talks, 21 contributed talks, and this year there were 2 panel discussions ('Error Field Correction' led by Andrew Cole of Columbia University and 'Application of Coils in General' led by Richard Buttery of General Atomics). Ted Strait of General Atomics also gave a summary of the International Tokamak Physics Activity (ITPA) MHD meeting in Padua, a group for which he is now the leader. In this special section of Plasma Physics and Controlled Fusion (PPCF) is a sample of the presentations at the workshop, which have been subject to the normal refereeing procedures of the journal. They include a review (A Boozer) and an invited talk (R Fitzpatrick) on error fields, an invited

  6. A microfabricated microfluidic bioMEMS device to model human brain aneurisms: the aneurysm-on-a-chip

    Science.gov (United States)

    Reece, Lisa M.; Khor, Jian Wei; Thakur, Raviraj; Amin, Ahmed; Wereley, Steven T.; Leary, James F.

    2015-03-01

    Aneurysms are pockets of blood that collect outside blood vessel walls forming dilatations and leaving arterial walls very prone to rupture. There is little information concerning the causes of intracranial aneurysm formation, growth, and rupture. Current treatments include: (1) clipping, and (2) coil embolization, including stent-assisted coiling. Further, the evolution of any aneurysm is assumed to be caused by the remodeling of the affected blood vessel's material constituents (tunica intima, tunica media, or tunica adventitia). Velocity, pressure, and wall shear stresses aid in the disease development of aneurysmal growth, while the shear force mechanisms effecting wound closure are elusive. To study aneurysm pathogenesis, a lab-on-a-chip device is the key to discovering the underlying mechanisms of these lesions. A two-dimensional microfluidic model, the Aneurysm-on-a-Chip™ (AOC), was the logical answer to study particle flow within an aneurysm "sac". The AOC apparatus can track particles/cells when it is coupled to particle image velocimetry software (PIV) package. The AOC fluid flow was visualized using standard microscopy techniques with commercial microparticles and human aortic smooth muscle cells (HASMC). Images were taken during fluid flow experiments and PIV was utilized to monitor the flow of particles within the "sac" region, as well as particles entering and exiting the device. Quiver plots were generated from fluid flow experiments using standard 7 μm latex particles and fixed HASMC in PBS. PIV analysis shows that the particles flowed nicely from input to output. Wall shear stress provided evidence that there was some back flow at the edges of the "sac" - an indicator of aneurysm development in human patients.

  7. The jet divertor coils

    International Nuclear Information System (INIS)

    This paper reports on the JET Tokamak which is to be modified to incorporate a divertor. A coil system in the vacuum vessel has been developed, which can produce a range of different divertor plasmas. The divertor coils are of conventional construction and are contained in this Inconel cases. They will be assembled in the vacuum vessel, welded into their cases and impregnated with epoxy resin

  8. LHCb magnet coils arrive

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    Each of the two coils for the LHCb magnet comprises 15 individual monolayer 'pancakes' of identical trapezoidal racetrack shape, and is bent at 45 degrees on the two transverse sides. Each pancake consists of eight turns of conductor, wound from a single length (approx. 290 m) of extruded aluminium. The coils have arrived at CERN; one of them is seen here being unloaded above the LHCb experimental cavern.

  9. Late angiographic and clinical follow-up results of 100 consecutive aneurysms treated with Onyx reconstruction: largest single-center experience

    International Nuclear Information System (INIS)

    adequate for stable long-term results in those with a large or giant aneurysm. However, the recanalization rate of 36% in these aneurysms is better than the reported results with other techniques, i.e., coils with or without adjunctive bare stents. (orig.)

  10. Recanalization of Splenic Artery Aneurysm After Transcatheter Arterial Embolization Using N-Butyl Cyanoacrylate

    International Nuclear Information System (INIS)

    A 65-year-old woman who had been diagnosed as having microscopic polyangiitis developed sudden abdominal pain and entered a state of shock. Abdominal CT showed massive hemoperitoneum, and emergent angiography revealed a ruptured splenic artery aneurysm. After direct catheterization attempts failed due to tortuous vessels and angiospasm, transcatheter arterial embolization using an n-butyl cyanoacrylate (NBCA)-lipiodol mixture was successfully performed. Fifty days later, the patient developed sudden abdominal pain again. Repeated angiography demonstrated recanalization of the splenic artery and splenic artery aneurysm. This time, the recanalized aneurysm was embolized using metallic coils with the isolation method. Physicians should keep in mind that recanalization can occur after transcatheter arterial embolization using N-butyl cyanoacrylate, which has been used as a permanent embolic agent.

  11. Image based hemodynamic modeling of cerebral aneurysms and the determination of the risk of rupture

    Science.gov (United States)

    Kroon, D. J.; Slump, C. H.; Sluzewski, M.; van Rooij, W. J. J.

    2006-03-01

    This paper is about the quantitative prediction of the long term outcome of the endovascular coiling treatment of a patient's cerebral aneurysm. It is generally believed that the local hemodynamic properties of the patient's cerebral arteries are strongly influencing the origin and growth of aneurysms. We describe our approach: modelling the flow in a 3D Rotational Angiography (3DRA) reconstruction of the aneurysms including supplying and draining blood vessels, in combination with simulations and experiments of artificial blood vessel phantom constructs and measurements. The goal is to obtain insight in the observed phenomena to support the diagnostic decision process in order to predict the outcome of the intervention with possible simulation of the flow alternation due to the pertinent intervention.

  12. Computer simulation of blood flow and colour doppler studies of experimental aneurysms: A correlative study

    International Nuclear Information System (INIS)

    The recent interest in the use endovascular techniques to treat cerebral aneurysm has stimulated the investigation of the role played by hemodynamic factors such as blood velocity and wall shear stress before and after aneurysmal creation. The purpose of this research is to create an animal model with a view to assay the feasibility of using a new angiographic-data-based computer simulation in evaluating the hemodynamics of aneurysms. Colour Doppler flow direction analysis measurements are used to validate the computer simulation. The analysis of the obtained data demonstrates that both colour Doppler and computer simulation are complementary. Both procedures show a rapid reversal of flow direction within the aneurysmal cavity during one cardiac cycle, and a shear stress increase in the proximal and distal neck of the aneurysm. 15 refs., 10 figs. (author)

  13. TFTR toroidal field coil design

    International Nuclear Information System (INIS)

    The design of the Tokamak Fusion Test Reactor (TFTR) Toroidal Field (TF) magnetic coils is described. The TF coil is a 44-turn, spiral-wound, two-pancake, water-cooled configuration which, at a coil current of 73.3 kiloamperes, produces a 5.2-Tesla field at a major radius of 2.48 meters. The magnetic coils are installed in titanium cases, which transmit the loads generated in the coils to the adjacent supporting structure. The TFTR utilizes 20 of these coils, positioned radially at 180 intervals, to provide the required toroidal field. Because it is very highly loaded and subject to tight volume constraints within the machine, the coil presents unique design problems. The TF coil requirements are summarized, the coil configuration is described, and the problems highlighted which have been encountered thus far in the coil design effort, together with the development tests which have been undertaken to verify the design

  14. NCSX Toroidal Field Coil Design

    Energy Technology Data Exchange (ETDEWEB)

    Kalish, M.; Rushinski, J.; Myatt, L.; Brooks, A.; Dahlgren, F.; Chrzanowski, J.; Reiersen, W.; Freudenberg, K.

    2005-10-07

    The National Compact Stellarator Experiment (NCSX) is an experimental device whose design and construction is underway at the Department of Energy's Princeton Plasma Physics Laboratory (PPPL). The primary coil systems for the NCSX device consist of the twisted plasma-shaping Modular Coils, the Poloidal Field Coils, and the Toroidal Field (TF) Coils. The TF Coils are D-shaped coils wound from hollow copper conductor, and vacuum impregnated with a glass-epoxy resin system. There are 18 identical, equally spaced TF coils providing 1/R field at the plasma. They operate within a cryostat, and are cooled by LN2, nominally, to 80K. Wedge shaped castings are assembled to the inboard face of these coils, so that inward radial loads are reacted via the nesting of each of the coils against their adjacent partners. This paper outlines the TF Coil design methodology, reviews the analysis results, and summarizes how the design and analysis support the design requirements.

  15. Potential advantages and limitations of the Leo stent in endovascular treatment of complex cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lv Xianli; Li Youxiang; Jiang Chuhan; Yang Xinjian [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China); Wu Zhongxue, E-mail: ttyyzjb@sina.com [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China)

    2011-08-15

    Objective: The Leo self-expandable stent is a new retractable stent that is delivered via a conventional catheter. The aim of this study was to evaluate the use of this stent for endovascular treatment of complex aneurysms. Methods: Twenty-eight complex cerebral aneurysms (27 saccular and 1 fusiform) in 28 patients were treated electively. They were located at the internal carotid artery (17), basilar trunk (3), anterior cerebral artery (1), anterior communicating artery (3), vertebral artery (2) and middle cerebral artery (2). One aneurysm exhibited recanalization after primary endovascular treatment without stent. Clinical outcome was assessed with the modified Glasgow Outcome Scale. Results: Deployment of Leo stent was successful in 26 lesions, and difficulties in stent positioning due to tortuous cerebral circulation in 2 cases, which were treated with Neuroform stent. Additional coil embolization was performed in 26 lesions. No permanent neurological deficits were encountered consequent to endovascular procedure. Complete or partial occlusion immediately after stent deployment was achieved in all aneurysms. There was no immediate coil embolization was chosen in 3 cases because of subsequent reduced filling of the aneurysms with contrast agent on angiograms. There were 3 asymptomatic parent artery occlusion related to the deployment of the Leo stent, one stent migration. Follow-up revealed patent stents in the remaining cases. No angiographic recurrences arose. Conclusion: The Leo stent is very useful for endovascular treatment of complex cerebral aneurysms because it is easy to navigate and place precisely. A drawback is that in-stent thrombosis caused by stent placement and stiffer delivery catheters to place larger stents.

  16. Potential advantages and limitations of the Leo stent in endovascular treatment of complex cerebral aneurysms

    International Nuclear Information System (INIS)

    Objective: The Leo self-expandable stent is a new retractable stent that is delivered via a conventional catheter. The aim of this study was to evaluate the use of this stent for endovascular treatment of complex aneurysms. Methods: Twenty-eight complex cerebral aneurysms (27 saccular and 1 fusiform) in 28 patients were treated electively. They were located at the internal carotid artery (17), basilar trunk (3), anterior cerebral artery (1), anterior communicating artery (3), vertebral artery (2) and middle cerebral artery (2). One aneurysm exhibited recanalization after primary endovascular treatment without stent. Clinical outcome was assessed with the modified Glasgow Outcome Scale. Results: Deployment of Leo stent was successful in 26 lesions, and difficulties in stent positioning due to tortuous cerebral circulation in 2 cases, which were treated with Neuroform stent. Additional coil embolization was performed in 26 lesions. No permanent neurological deficits were encountered consequent to endovascular procedure. Complete or partial occlusion immediately after stent deployment was achieved in all aneurysms. There was no immediate coil embolization was chosen in 3 cases because of subsequent reduced filling of the aneurysms with contrast agent on angiograms. There were 3 asymptomatic parent artery occlusion related to the deployment of the Leo stent, one stent migration. Follow-up revealed patent stents in the remaining cases. No angiographic recurrences arose. Conclusion: The Leo stent is very useful for endovascular treatment of complex cerebral aneurysms because it is easy to navigate and place precisely. A drawback is that in-stent thrombosis caused by stent placement and stiffer delivery catheters to place larger stents.

  17. Effect of Aneurysmal Subarachnoid Hemorrhage on Word Generation

    Directory of Open Access Journals (Sweden)

    Daniella Ladowski

    2014-01-01

    Full Text Available Background. Aneurysmal subarachnoid hemorrhage (aSAH survivors commonly exhibit impairment on phonemic and semantic fluency tests; however, it is unclear which of the contributing cognitive processes are compromised in aSAH patients. One method of disentangling these processes is to compare initial word production, which is a rapid, semiautomatic, frontal-executive process, and late phase word production, which is dependent on more effortful retrieval and lexical size and requires a more distributed neural network. Methods. Seventy-two individuals with aSAH and twenty-five control subjects were tested on a cognitive battery including the phonemic and semantic fluency task. Demographic and clinical information was also collected. Results. Compared to control subjects, patients with aSAH were treated by clipping and those with multiple aneurysms were impaired across the duration of the phonemic test. Among patients treated by coiling, those with anterior communicating artery aneurysms or a neurological complication (intraventricular hemorrhage, vasospasm, and edema showed worse output only in the last 45 seconds of the phonemic test. Patients performed comparably to control subjects on the semantic test. Conclusions. These results support a “diffuse damage” hypothesis of aSAH, indicated by late phase phonemic fluency impairment. Overall, the phonemic and semantic tests represent a viable, rapid clinical screening tool in the postoperative assessment of patients with aSAH.

  18. Role of hydration and intramolecular interactions in the helix-coil transition and helix-helix assembly in a deca-alanine peptide

    CERN Document Server

    Tomar, Dheeraj S; Pettitt, B M; Asthagiri, D

    2015-01-01

    For a model deca-alanine peptide the cavity (ideal hydrophobic) contribution to hydration favors the helix state in the coil-to-helix transition and the paired helix bundle in the assembly of two helices. The energetic contributions of attractive protein-solvent interactions are separated into a short-range part arising from interactions with solvent in the first hydration shell and the remaining long-range part. In the helix-coil transition, short-range attractive protein-solvent interactions outweigh hydrophobic hydration and favor the unfolded coil states. Analysis of enthalpic effects shows that it is the favorable hydration of the peptide backbone that favors the unfolded state. Protein intramolecular interactions favor the helix state and are decisive in folding. In the pairing of two helices, the cavity contribution outweighs short-range attractive protein-water interactions. However, long-range, protein-solvent attractive interactions can either enhance or reverse this trend depending on the mutual or...

  19. Complex pathologies of angiotensin Ⅱ-induced abdominal aortic aneurysms

    Institute of Scientific and Technical Information of China (English)

    Alan DAUGHERTY; Lisa A. CASSIS; Hong LU

    2011-01-01

    Angiotensin Ⅱ (Angll) is the primary bioactive peptide of the renin angiotensin system that plays a critical role in many cardiovascular diseases.Subcutaneous infusion of Angll into mice induces the development of abdominal aortic aneurysms (AAAs).Like human AAAs,Angll-induced AAA tissues exhibit progressive changes and considerable heterogeneity.This complex pathology provides an impediment to the quantification of aneurysmal tissue composition by biochemical and immunostaining techniques.Therefore,while the mouse model of Angll-induced AAAs provides a salutary approach to studying the mechanisms of the evolution of AAAs in humans,meaningful interpretation of mechanisms requires consideration of the heterogeneous nature of the diseased tissue.

  20. Peak Trekking of Hierarchy Mountain for the Detection of Cerebral Aneurysm using Modified Hough Circle Transform

    OpenAIRE

    Mitra, Jubin; Chandra, Abhijit; Halder, Tanmay

    2013-01-01

    The Circle of Willis is in the junction of two carotid arteries and two vertebral arteries that supply the brain with nutrition. Junctions where these arteries come together may develop weak spots that can balloon out and fill with blood, creating aneurysms. These sac-like areas may leak or rupture, spilling blood into surrounding tissues which may cause artery spasm leading to potential stroke or even death. Clipping and coiling are two treatment options preferred by neurosurgeon which requi...

  1. Ruptured, dissecting posterior inferior cerebellar artery aneurysms: endovascular treatment without parent vessel occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Cellerini, Martino [Careggi Hospital, Interventional Neuroradiology, Florence (Italy); Centro Traumatologico-Ortopedico, Unita di Neuroradiologia, Florence (Italy); Mangiafico, Salvatore [Careggi Hospital, Interventional Neuroradiology, Florence (Italy); Ammannati, Franco; Mennonna, Pasquale [Careggi Hospital, Neurosurgery, Florence (Italy); Ambrosanio, Gennaro; Muto, Mario [Cardarelli Hospital, Neuroradiology, Naples (Italy); Galasso, Luigi [S. Luca Hospital, Neuroradiology, Salerno (Italy)

    2008-04-15

    Treatment of a dissecting aneurysm of the medullary segments of the posterior inferior cerebellar artery (PICA) usually entails trapping of the diseased arterial segment with possible sacrifice of brainstem perforators. The goal of the work was to review our experience with selective coiling of ruptured, dissecting aneurysms of the anterolateral segments of the PICA without parent vessel occlusion. Eleven consecutive patients (9 women, 2 men, mean age 47.2 years) were retrospectively reviewed from a prospectively acquired neuroradiological database. On admission three patients had Hunt and Hess (HH) grade I, three HH grade II, two HH grade III, and one HH grade IV. Outcome was evaluated according to the modified Rankin scale (mRS) score. Follow-up (mean:19.4 months) consisted of magnetic resonance angiography and/or digital subtraction angiography in ten patients. Ten patients had mRS score 0 and one mRS score 2. No treatment failure occurred. The aneurysm was completely occluded in seven patients, a neck residue was present in two, and a loose coil mesh was present in two. Recurrence occurred in three patients, and all were successfully retreated for a total of 13 procedures. Procedure-related complications were all without clinical consequences and included a coil perforation in one procedure and stagnant filling of the parent vessel in six procedures. PICA occlusion did not occur in any patient. Coiling of ruptured, isolated dissecting aneurysms of the PICA without parent vessel occlusion is feasible, relatively safe and effective in preventing early/medium-term rebleeding. A strict angiographic follow-up program is, however, necessary to detect recurrence. (orig.)

  2. Management of multiple type Ⅱ endoleaks detected by duplex ultrasound after endovascular abdominal aneurysm repair

    Institute of Scientific and Technical Information of China (English)

    GUO Da-qiao; LI Wei-miao; JIANG Jun-hao; SHI Zhen-yu; WANG Yu-qi; FU Wei-guo

    2012-01-01

    We reported a case of multiple type Ⅱ endoleaks detected by duplex ultrasound after endovascular abdominal aneurysm repair.The patient was undergoing warfarin therapy.Duplex ultrasound was applied as the sole surveillance method during follow-up and provided the concerned information for reintervention.The endoleaks were successfully repaired by coil embolization of the collaterals from the internal iliac artery feeding the fourth lumbar artery.

  3. Ruptured, dissecting posterior inferior cerebellar artery aneurysms: endovascular treatment without parent vessel occlusion

    International Nuclear Information System (INIS)

    Treatment of a dissecting aneurysm of the medullary segments of the posterior inferior cerebellar artery (PICA) usually entails trapping of the diseased arterial segment with possible sacrifice of brainstem perforators. The goal of the work was to review our experience with selective coiling of ruptured, dissecting aneurysms of the anterolateral segments of the PICA without parent vessel occlusion. Eleven consecutive patients (9 women, 2 men, mean age 47.2 years) were retrospectively reviewed from a prospectively acquired neuroradiological database. On admission three patients had Hunt and Hess (HH) grade I, three HH grade II, two HH grade III, and one HH grade IV. Outcome was evaluated according to the modified Rankin scale (mRS) score. Follow-up (mean:19.4 months) consisted of magnetic resonance angiography and/or digital subtraction angiography in ten patients. Ten patients had mRS score 0 and one mRS score 2. No treatment failure occurred. The aneurysm was completely occluded in seven patients, a neck residue was present in two, and a loose coil mesh was present in two. Recurrence occurred in three patients, and all were successfully retreated for a total of 13 procedures. Procedure-related complications were all without clinical consequences and included a coil perforation in one procedure and stagnant filling of the parent vessel in six procedures. PICA occlusion did not occur in any patient. Coiling of ruptured, isolated dissecting aneurysms of the PICA without parent vessel occlusion is feasible, relatively safe and effective in preventing early/medium-term rebleeding. A strict angiographic follow-up program is, however, necessary to detect recurrence. (orig.)

  4. Mechanical Response and Conformational Amplification in α-Helical Coiled Coils

    OpenAIRE

    Yogurtcu, Osman N.; Wolgemuth, Charles W.; Sun, Sean X.

    2010-01-01

    α-Helical coiled coils (CCs) are ubiquitous tertiary structural domains that are often found in mechanoproteins. CCs have mechanical rigidity and are often involved in force transmission between protein domains. Although crystal structures of CCs are available, information about their conformational flexibility is limited. The role of hydrophobic interactions in determining the CC conformation is not clear. In this work we examined the mechanical responses of typical CCs and constructed a coa...

  5. TFTR coil case design

    International Nuclear Information System (INIS)

    The TFTR (TOKAMAK Fusion Test Reactor) TF (Toroidal Field) coil cases are highly loaded structures designed within severe constraints. Foremost among these are basic machine geometry, material characteristics of both the case and the copper/epoxy matrix it supports, and overall cost. Scoping and parametric studies have been performed continuously since conceptual design. The progression of design decisions including coil shape, support locations and their stiffnesses, material selection, and element sizing are described. The significant variables are identified for each of the studies. The current coil case design is presented in detail along with aspects of the design still under consideration. Questions that remain involve the effects of limitations placed upon the coil materials (copper, epoxy) themselves. Resolution of these questions is to be accomplished by development tests of coil elements similar to those in the current design. Two alternate designs have been held in reserve pending completion of the development tests. Each is briefly described as to its basic configuration, potential for improvement, and its effect on the overall device

  6. Transcatheter coil occluder for closure of ventricular septal defect (a report of 4 cases)

    International Nuclear Information System (INIS)

    Objective: To explore the indication, methodology and complication of transcatheter coil closure of ventricular septal defect (VSD) in children. Methods: Transcatheter closure of perimembranous VSD with coils was performed in 4 cases from 2003 to 2005. The Duct-Occlude (pfm) and detachable coil (Cook) were chosen for embolization depending on the results of the left ventricular angiogram. The coil size was generally about 1-4 mm larger than the diameter of VSD. Follow up was carried out with echocardiography, ultrasound and clinical examination. Results: The defect diameters of the four cases were 2.0 mm, 2.7 mm, 2.5 mm and 1.5 mm respectively. The Duct-Occlude were successfully implanted in 3 cases of perimembranous VSD with the same type coil (OD[mm]7-3-6, windings 5-3-4) for each. One detachable coil (Cook) (5 x 5) was implanted in the remaining case. All cases had trivial residual shunt immediately after implantation which disappeared 24 hours later. Follow-up for 2 months to one year showed no coil displacement and secondary bacterial arteritis. No tricuspid and aortic regurgitation, no emboli, no endocarditis, and no arrhythmia were found. Conclusions: Coil closure of some small VSD with membranate part pseudo-ventricular aneurysm has good efficacy with the advantages of simple operation, less metal content and mini-invasion also applicable for infants. (authors)

  7. Tobacco smoking and aortic aneurysm

    DEFF Research Database (Denmark)

    Sode, Birgitte F; Nordestgaard, Børge G; Grønbæk, Morten;

    2012-01-01

    from the Copenhagen City Heart Study followed for up to 34years and in 56,211 individuals from the Copenhagen General Population Study followed for up to 7years. RESULTS: During follow-up, 335 and 169 individuals developed aortic aneurysm outcomes in the Copenhagen City Heart Study and Copenhagen...... General Population Study, respectively. According to the magnitude of the hazard ratios, tobacco consumption was the most important risk factor for hospitalization and death from aortic aneurysm, followed by male sex and hypertension in both cohorts. The population attributable risk of aortic aneurysm...... outcomes due to tobacco consumption was 64% and 47% in the Copenhagen City Heart Study and Copenhagen General Population Study, respectively, and ranked highest among population attributable risks of aortic aneurysm in both cohorts. The absolute 10-year risk for hospitalization or death from aortic...

  8. Cluster headache and intracranial aneurysm

    OpenAIRE

    Valença, Marcelo Moraes; Andrade-Valença, Luciana P. A.; Martins, Carolina; de Aragão, Maria Fátima Vasco; Batista, Laécio Leitão; Peres, Mario Fernando Prieto; da Silva, Wilson Farias

    2007-01-01

    In the present study we describe the cases of two patients with cluster-like headache related to intracranial carotid artery aneurysm. One of these patients responded to verapamil prescription with headache resolution. In both cases the surgical clipping of the aneurysm resolved the cluster pain. These findings strongly suggest a pathophysiological link between the two conditions. The authors discuss the potential pathophysiological mechanisms underlying cluster-like headache due to intracran...

  9. Embolization of ruptured intracranial aneurysms during the period of cerebral vasospasm

    International Nuclear Information System (INIS)

    Objective: To retrospectively analyze our experience of embolization of ruptured intracranial aneurysms during the period of cerebral vasospasm (CVS). Methods: Thirty-seven patients with ruptured intracranial aneurysms were embolized with electrolytic detachable coils during the period of CVS (days 4 to 14). Group A included the 14 patients with angiographic CVS and group B included 23 patients without angiographic CVS. All except 2 patients were transferred to our department during the CVS period. Glasgow outcome score (GOS) was evaluated 3 months after the treatment. Results: Twelve patients in group A successfully received the aneurysm embolization and treatment of the CVS with intraarterial papaverine injection and balloon angioplasty. GOS in 3 months was good recovery in 7 patients, moderate disability in 2, severe disability in 1, and dead in 2, respectively. Embolization failed in 2 patients because the micro catheters could't pass the spasmodic parent arteries. All the aneurysms in group B were successfully embolized. GOS were good recovery in 18 patients, moderate disability in 2, severe disability in 2, and dead in 1, respectively. There was no intraprocedural aneurysmal rupture but with 2 thromboembolic events. No rebleeding occurred during the mean 11 months follow-up. Conclusions: The so-called 'period of CVS' isn't always associated with CVS in angiograpy. Embolization of ruptured intracranial aneurysms during the period of pure CVS doesn't carry an increased risk. Both the aneurysms and CVS can be treated during the single procedure. It can reduce the rebleeding rate in hospital and improve the prognosis of the patients with CVS. (authors)

  10. Flow Diverters for Intracranial Aneurysms

    Directory of Open Access Journals (Sweden)

    Yazan J. Alderazi

    2014-01-01

    Full Text Available Flow diverters (pipeline embolization device, Silk flow diverter, and Surpass flow diverter have been developed to treat intracranial aneurysms. These endovascular devices are placed within the parent artery rather than the aneurysm sac. They take advantage of altering hemodynamics at the aneurysm/parent vessel interface, resulting in gradual thrombosis of the aneurysm occurring over time. Subsequent inflammatory response, healing, and endothelial growth shrink the aneurysm and reconstruct the parent artery lumen while preserving perforators and side branches in most cases. Flow diverters have already allowed treatment of previously untreatable wide neck and giant aneurysms. There are risks with flow diverters including in-stent thrombosis, perianeurysmal edema, distant and delayed hemorrhages, and perforator occlusions. Comparative efficacy and safety against other therapies are being studied in ongoing trials. Antiplatelet therapy is mandatory with flow diverters, which has highlighted the need for better evidence for monitoring and tailoring antiplatelet therapy. In this paper we review the devices, their uses, associated complications, evidence base, and ongoing studies.

  11. Clinical presentation of cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Cianfoni, Alessandro [Neurocentro della Svizzera Italiana, Ospedale Civico di Lugano, via Tesserete, 46, 6900 Lugano (Switzerland); Pravatà, Emanuele, E-mail: emanuele.pravata@gmail.com [Neurocentro della Svizzera Italiana, Ospedale Civico di Lugano, via Tesserete, 46, 6900 Lugano (Switzerland); De Blasi, Roberto [Neurocentro della Svizzera Italiana, Ospedale Civico di Lugano, via Tesserete, 46, 6900 Lugano (Switzerland); Tschuor, Costa Silvia [Dipartimento di Radiologia, Ospedale Civico di Lugano, via Tesserete, 46, 6900 Lugano (Switzerland); Bonaldi, Giuseppe [U.O. Neuroradiologia, Ospedali Riuniti di Bergamo, Largo Barozzi, 1, 24128 Bergamo (Italy)

    2013-10-01

    Presentation of a cerebral aneurysm can be incidental, discovered at imaging obtained for unrelated causes, can occur in the occasion of imaging obtained for symptoms possibly or likely related to the presence of an unruptured aneurysm, or can occur with signs and symptoms at the time of aneurismal rupture. Most unruptured intracranial aneurysms are thought to be asymptomatic, or present with vague or non-specific symptoms like headache or dizziness. Isolated oculomotor nerve palsies, however, may typically indicate the presence of a posterior circulation aneurysm. Ruptured intracranial aneurysms are by far the most common cause of non-traumatic subarachnoid hemorrhage and represent a neurological emergency with potentially devastating consequences. Subarachnoid hemorrhage may be easily suspected in the presence of sudden and severe headache, vomiting, meningism signs, and/or altered mental status. However, failure to recognize milder and more ambiguous clinical pictures may result in a delayed or missed diagnosis. In this paper we will describe the clinical spectrum of unruptured and ruptured intracranial aneurysms by discussing both typical and uncommon clinical features emerging from the literature review. We will additionally provide the reader with descriptions of the underlying pathophysiologic mechanisms, and main diagnostic pitfalls.

  12. Clinical presentation of cerebral aneurysms

    International Nuclear Information System (INIS)

    Presentation of a cerebral aneurysm can be incidental, discovered at imaging obtained for unrelated causes, can occur in the occasion of imaging obtained for symptoms possibly or likely related to the presence of an unruptured aneurysm, or can occur with signs and symptoms at the time of aneurismal rupture. Most unruptured intracranial aneurysms are thought to be asymptomatic, or present with vague or non-specific symptoms like headache or dizziness. Isolated oculomotor nerve palsies, however, may typically indicate the presence of a posterior circulation aneurysm. Ruptured intracranial aneurysms are by far the most common cause of non-traumatic subarachnoid hemorrhage and represent a neurological emergency with potentially devastating consequences. Subarachnoid hemorrhage may be easily suspected in the presence of sudden and severe headache, vomiting, meningism signs, and/or altered mental status. However, failure to recognize milder and more ambiguous clinical pictures may result in a delayed or missed diagnosis. In this paper we will describe the clinical spectrum of unruptured and ruptured intracranial aneurysms by discussing both typical and uncommon clinical features emerging from the literature review. We will additionally provide the reader with descriptions of the underlying pathophysiologic mechanisms, and main diagnostic pitfalls

  13. Antiparallel coiled-coil-mediated dimerization of myosin X.

    Science.gov (United States)

    Lu, Qing; Ye, Fei; Wei, Zhiyi; Wen, Zilong; Zhang, Mingjie

    2012-10-23

    Processive movements of unconventional myosins on actin filaments generally require motor dimerization. A commonly accepted myosin dimerization mechanism is via formation of a parallel coiled-coil dimer by a stretch of amino acid residues immediately carboxyl-terminal to the motor's lever-arm domain. Here, we discover that the predicted coiled-coil region of myosin X forms a highly stable, antiparallel coiled-coil dimer (anti-CC). Disruption of the anti-CC either by single-point mutations or by replacement of the anti-CC with a parallel coiled coil with a similar length compromised the filopodial induction activity of myosin X. We further show that the anti-CC and the single α-helical domain of myosin X are connected by a semirigid helical linker. The anti-CC-mediated dimerization may enable myosin X to walk on both single and bundled actin filaments. PMID:23012428

  14. CHARACTERIZATION OF PATIENTS WITH ENDOVASCULAR TREATMENT OF DISSECTING ANEURYSMS OF POSTERIOR CEREBRAL CIRCULATION IN CARTAGENA DE INDIAS

    Directory of Open Access Journals (Sweden)

    Rueda-Tamayo Leidy

    2015-12-01

    Full Text Available Introduction: the intracraneal aneurysms are local and permanent dilations in the artery. Objective: to describe the clinical, imagenologic and effectiveness of endovascular treatment in terms of its independence and mortality in patients with dissecting aneurysms of posterior cerebral circulation in Cartagena. Methods: a descriptive study was carried out with patients 18 years or older with a diagnosis of dissecting aneurysms of posterior cerebral circulation who received endovascular treatment in the period between January 2007 and December 2014 in the medical center Neurodinamia. The variables related to personal medical history, diagnosis and characteristics of the aneurysm, devices used for treatment, time clinical and imagenologic follow-up and complications were measured. Descriptive statistical analysis was performed according to the nature of the variables. Results: nineteen patients were analyzed to receive endovascular treatments. The average of age was 55 years. The subarachnoid hemorrhage was the most frequent clinical case; this was diagnosed with CT in 89.5%. The location in the PICA and vertebral artery were 36.8% and 31.6%, respectively. The devices used were coils in 36.8%, followed by coils and stent with 31.6%, and Onyx with 21.0%. At the end of VTE this was classified as favorable outcome in 18 patients (94.7%; however, there was one death during hospital care (5.3%. The Rankin scale showed improvement in 84.2% (16 patients. Conclusions: the endovascular treatment of dissecting aneurysms posterior cerebral circulation and the aneurysm occlusion showed high success rates 94.7%, patients (84.2% showed positive results after 30 days of treatment. Rev.cienc.biomed. 2015;6(2:298-308 KEY WORDS Aneurysm; Neurosurgery; Radiology interventional.

  15. Intracranial aneurysm associated with relapsing polychondritis

    Energy Technology Data Exchange (ETDEWEB)

    Coumbaras, M.; Boulin, A.; Pierot, L. [Dept. of Neuroradiology, Hopital Foch, Suresnes (France); Piette, A.M.; Bletry, O. [Dept. of Medicine, Hopital Foch, Suresnes (France); Graveleau, P. [Dept. of Neurology, Hopital Foch, Suresnes (France)

    2001-07-01

    We describe a 50-year-old man with relapsing polychondritis (RP) involving auricular cartilage, uveitis and hearing loss, who had an aneurysm of the anterior cerebral artery. Intracranial aneurysm is a rare manifestation of RP. (orig.)

  16. Brain Aneurysm: Early Detection and Screening

    Science.gov (United States)

    ... and Screening A- A A+ Early Detection and Screening Brain aneurysms can be similar to heart attacks. ... aneurysm is about to rupture. Fortunately, through imaging screening techniques, individuals at high risk of harboring a ...

  17. Surveillance intervals for small abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Bown, Matthew J; Sweeting, Michael J; Brown, Louise C;

    2013-01-01

    Small abdominal aortic aneurysms (AAAs [3.0 cm-5.4 cm in diameter]) are monitored by ultrasound surveillance. The intervals between surveillance scans should be chosen to detect an expanding aneurysm prior to rupture....

  18. Aneurysms - Multiple Languages: MedlinePlus

    Science.gov (United States)

    ... Supplements Videos & Tools You Are Here: Home → Multiple Languages → All Health Topics → Aneurysms URL of this page: https://medlineplus.gov/languages/aneurysms.html Other topics A-Z A B ...

  19. Aortic aneurysm secondary to umbilical artery catheterization

    International Nuclear Information System (INIS)

    A 14-month-girl presented with an asymptomatic posterior mediastinal mass. She had a history of prematurity, umbilical artery catheterization, and sepsis. The diagnosis of aortic aneurysm was made by dynamic computed tomography. The aneurysm was successfully resected. (orig.)

  20. NET model coil test possibilities

    International Nuclear Information System (INIS)

    A single full size coil for NET/INTOR represents an investment of the order of 40 MUC (Million Unit Costs). Before such an amount of money or even more for the 16 TF coils is invested as much risks as possible must be eliminated by a comprehensive development programme. In the course of such a programme a coil technology verification test should finally prove the feasibility of NET/INTOR TF coils. This study report is almost exclusively dealing with such a verification test by model coil testing. These coils will be built out of two Nb3Sn-conductors based on two concepts already under development and investigation. Two possible coil arrangements are discussed: A cluster facility, where two model coils out of the two Nb3TF-conductors are used, and the already tested LCT-coils producing a background field. A solenoid arrangement, where in addition to the two TF model coils another model coil out of a PF-conductor for the central PF-coils of NET/INTOR is used instead of LCT background coils. Technical advantages and disadvantages are worked out in order to compare and judge both facilities. Costs estimates and the time schedules broaden the base for a decision about the realisation of such a facility. (orig.)

  1. Treatment of a Common Iliac Aneurysm by Endovascular Exclusion Using the Amplatzer Vascular Plug and Femorofemoral Crossover Graft

    International Nuclear Information System (INIS)

    We report our initial experience using the Amplatzer Vascular Plug II (AVP2) in the treatment of a left common iliac aneurysm. Following investigation by computerized tomographic angiography and catheter angiography, a 79-year-old man was found to have a markedly tortuous iliac system, with a left common iliac artery aneurysm that measured 48 mm in maximal diameter. Due to the patient's age and comorbidities the surgical opinion was that conventional open repair was not suitable. However, due to the tortuous nature of the aneurysm and iliac vessels, standard endovascular repair, using either a bifurcated or an aorto-uni-iliac stent graft, was also not possible. A combined approach was used by embolizing the ipsilateral internal iliac artery using coils and excluding the aneurysm using two AVP2 occlusion devices, followed by femorofemoral crossover grafting. Total aneurysm occlusion was achieved using this method and this allowed the patient to have a much less invasive surgical procedure than with conventional open repair of common iliac aneurysms, thus avoiding potential comorbidity and mortality.

  2. True Giant Posterior Tibial Artery Aneurysm

    OpenAIRE

    Patrizio Colotto; Gabriele Testi; Giacomo Di Iasio; Alessandro Robaldo

    2012-01-01

    We report an unusual case of true atherosclerotic posterior tibial artery (PTA) aneurysm without any apparent causative history. To our knowledge, in the English Literature only seven previously cases of true PTA aneurysms are reported. Due to its location, this lesion may require surgical intervention and removal. The presentation, the diagnostic evaluation, and the surgical management of the aneurysm are discussed.

  3. Microsurgical cerebral aneurysm training porcine model

    Directory of Open Access Journals (Sweden)

    Jon Olabe

    2011-01-01

    Full Text Available The authors developed a simple reproducible technique for aneurysm creation and adapted it to mimic intracranial dissection conditions using glue application as a pseudo-arachnoid type layer. Ten 1-2-month-old healthy domestic swine were employed under general anesthesia. A novel technique for bifurcation aneurysm creation was developed using two arteries and a vein. After aneurysm creation, diluted sulfuric acid was applied on the dome with a micropipette to increase aneurysm fragility in selected zones. The surgical field was then dried and contact glue was applied around the vascular complex in a circular manner so as to emulate arachnoidal connection fibers. Microsurgical dissection of the aneurysm and surrounding vessels was performed by delicately removing the adhesive substance. Diverse aneurysm clipping techniques, emergency rupture situations and vascular reconstruction procedures were trained. Twenty-two aneurysms were created at several vascular sites, one aneurysm dome ruptured during application of sulfuric acid, two aneurysm models were proved to be thrombosed, two aneurysms ruptured during the dissection and no intraoperative deaths occurred. All aneurysms were clipped in an acceptable manner. This bifurcation aneurysm model provides a novel training system to be used not only by neurosurgeons but also by neurovascular interventionists.

  4. Internal carotid artery bifurcation aneurysms. Surgical experience

    International Nuclear Information System (INIS)

    Internal carotid artery (ICA) bifurcation aneurysms are relatively uncommon and frequently rupture at a younger age compared to other intracranial aneurysms. We have treated a total of 999 patients for intracranial aneurysms, of whom 89 (8.9%) had ICA bifurcation aneurysms, and 42 of the 89 patients were 30 years of age or younger. The present study analyzed the clinical records of 70 patients with ICA bifurcation aneurysms treated from mid 1997 to mid 2003. Multiple aneurysms were present in 15 patients. Digital subtraction angiography films were studied in 55 patients to identify vasospasm and aneurysm projection. The aneurysm projected superiorly in most of these patients (37/55, 67.3%). We preferred to minimize frontal lobe retraction, so widely opened the sylvian fissure to approach the ICA bifurcation and aneurysm neck. Elective temporary clipping was employed before the final dissection and permanent clip application. Vasospasm was present in 24 (43.6%) of 55 patients. Forty-eight (68.6%) of the 70 patients had good outcome, 14 (20%) had poor outcome, and eight (11.4%) died. Patients with ICA bifurcation aneurysms tend to bleed at a much younger age compared to those with other intracranial aneurysms. Wide opening of the sylvian fissure and elective temporary clipping of the ICA reduces the risk of intraoperative rupture and perforator injury. Mortality was mainly due to poor clinical grade and intraoperative premature aneurysm rupture. (author)

  5. Modular coils: a promising toroidal-reactor-coil system

    International Nuclear Information System (INIS)

    The concept of modular coils originated from a need to find reactor-relevant stellarator windings, but its usefulness can be extended to provide an externally applied, additional rotational transform in tokamaks. Considerations of (1) basic principles of modular coils, (2) types of coils, (3) types of configurations (general, helically symmetric, helically asymmetric, with magnetic well, with magnetic hill), (4) types of rotational transform profile, and (5) structure and origin of ripples are given. These results show that modular coils can offer a wide range of vacuum magnetic field configurations, some of which cannot be obtained with the classical stellarator or torsatron coil configuration

  6. Correlation between Hemodynamics and Treatment Outcome of Intracranial Aneurysms after Intervention with Flow Diverters

    Science.gov (United States)

    Paliwal, Nikhil; Damiano, Robert; Davies, Jason; Siddiqui, Adnan; Meng, Hui

    2015-11-01

    Endovascular intervention by Flow Diverter (FD) - a densely woven stent - occludes an aneurysm by inducing thrombosis in the aneurysm sac and reconstructing the vessel. Hemodynamics plays a vital role in the thrombotic occlusion of aneurysms and eventual treatment outcome. CFD analysis of pre- and post-treatment aneurysms not only provides insight of flow modifications by FD, but also allows investigation of interventional strategies and prediction of their outcome. In this study 80 patient-specific aneurysms treated with FDs were retrospectively studied to evaluate the effect of intervention. Out of these cases, 16 required retreatment and thus are considered as having unfavorable outcome. Clinical FD deployment in these cases was simulated using an efficient virtual stenting workflow. CFD analysis was carried out on both pre- and post-treatment cases, and changes in hemodynamic parameters were calculated. Support vector machine algorithm was used to correlate the hemodynamic changes with outcome. Results show that cases having higher flow reduction into the aneurysmal sac have a better likelihood of occlusion. This suggests that changes in hemodynamics can be potentially used to predict the outcome of different clinical intervention strategies in aneurysms. This work was supported by the National Institutes of Health (R01 NS091075).

  7. Delayed Ischemic Stroke after Flow Diversion of Large Posterior Communicating Artery Aneurysm.

    Science.gov (United States)

    Kim, Si On; Chung, Yeon Gu; Won, Yu Sam; Rho, Myung Ho

    2016-03-01

    For securing large, giant, and wide-neck aneurysms, conventional coil embolization has substantial limitations, such as incomplete occlusion, recanalization, and a high recurrence rate. To overcome these limitations, a novel paradigm was suggested and, as a result, flow-diverting device was developed. The flow-diverting device is an innovative and effective technique to allow securing of large, giant, and wide-neck aneurysms. In numerous studies, the flow-diverting device has shown better outcomes than coil embolization. However, the flow-diverting device has also some risks, including rupture of aneurysm, intracerebral hemorrhage, and ischemic stroke. In addition, with more experience, unexpected complications are also reported.5)7) In the present case, we experienced a delayed ischemic stroke at 27 days after endovascular treatment. The patient had multiple aneurysms and, among them, we treated a large posterior communicating artery aneurysm using Pipeline™ Embolization Device. The patient was tolerable for 25 days, but then suddenly presented intermittent right hemiparesis. In the initial diffusion magnetic resonance imaging (MRI), there was no acute lesion; however, in the follow-up MRI, an acute ischemic stroke was found in the territory of anterior choroidal artery which was covered by Pipeline Embolization Device. We suspect that neo-intimal overgrowth or a tiny thrombus have led to this delayed complication. Through our case, we learned that the neurosurgeon should be aware of the possibility of delayed ischemic stroke after flow diversion, as well as, long-term close observation and follow-up angiography are necessary even in the event of no acute complications. PMID:27114962

  8. Inflammation in human cerebral aneurysms: pathogenesis, diagnostic imaging, genetics, and therapeutics

    Directory of Open Access Journals (Sweden)

    Sarah A Dooley

    2015-06-01

    Full Text Available Intracranial aneurysms are a life-threatening cerebrovascular pathology with a probability of spontaneous rupture. Current intervention techniques carry inherent risk. Recent investigation has reinforced inflammation's role in the pathophysiological process of cerebral aneurysms. These data suggest alternative diagnostic and noninvasive therapeutic strategies. Furthermore, novel characteristics of the underlying disease have been elucidated through distinct bioinformatic and gene expression profile analyses. This article will emphasize the most recent investigation, highlighting findings of clinical significance and etiological relevance.

  9. Influence of Selective Biochemical and Morphological Agents on Natural History of Aneurysm of Abdominal Aorta Development

    OpenAIRE

    Wołoszko, Tomasz; Skórski, Maciej; Kwasiborski, Przemysław; Kmin, Ewelina; Gałązka, Zbigniew; Pogorzelski, Ryszard

    2016-01-01

    Background The development of abdominal aortic aneurysm (AAA) is probably influenced by many factors. The role of some of these factors, such as intraluminal thrombus (ILT) or cystatin C serum levels, remains controversial. Proving their influence could have therapeutic implications for some patients with AAA. Associations between the rate of increase in diameter of an aneurysm and ILT, as well as other factors, including biochemical factors (C-Reactive Protein – CRP, cystatin C), age, sex, a...

  10. Successful abdominal aortic aneurysm resection in long-term survivors of cardiac transplantation.

    OpenAIRE

    Defraigne, Jean-Olivier; SakalihasanN, Natzi; DEMOULIN, Julie; Limet, Raymond

    1995-01-01

    With the improvement of survival rates following cardiac transplantation, the probability of recipients developing extracardiac disease is increased. Three cases are reported of abdominal aortic aneurysm successfully operated on in cardiac allograft recipients 1 to 4 years after transplantation. Indications for transplantation were valvular, idiopathic and ischaemic cardiomyopathy. Post-transplant hypertension and hyperlipidaemia may have played a role in the rapid growth of the aneurysms. Ca...

  11. [Subdural hemorrhage of aneurysmal origin].

    Science.gov (United States)

    Sánchez, R; Alfaro, A; Perla, C; Blasco, R; Cortés, F; Solís, P

    1994-02-01

    Although most subdural hematomas are considered to be venous in origin, they may also be of arterial origin. When subdural bleeding is due to the rupture of an intracranial aneurysm, most commonly at the middle cerebral or internal carotid arteries, the amount of subdural blood is usually small and of no clinical importance. We describe two patients with subdural hematomas secondary to rupture of an intracranial aneurysm, who needed prompt surgical treatment. The first patient had a left internal carotid artery aneurysm at the origin of the ophthalmic artery. In the second patient the aneurysm was at the anterior communicating artery and rebled into the subdural space directly through a right intraparenchymatous frontobasal hematoma. The most probable mechanism of subdural bleeding in our two patients was the existence of adhesions between the aneurysm and the arachnoid due to previous minor hemorrhages. The indication of cerebral angiography in a patient with subdural hematoma is based mainly upon the existence of meningeal signs, the presence of blood in more than one intracranial compartment or the rapid progression of bleeding. PMID:8204251

  12. Leveraging intrinsic chain anisotropy to align coil-coil block copolymers with magnetic fields

    Science.gov (United States)

    Rokhlenko, Yekaterina; Zhang, Kai; Gopinadhan, Manesh; Larson, Steve; Majewski, Pawel; Yager, Kevin; Gopalan, Padma; O'Hern, Corey; Osuji, Chinedum

    Magnetic field alignment of block copolymers (BCPs) has typically relied on the presence of liquid crystalline or crystalline assemblies to provide sufficient magnetic anisotropy to drive alignment. Recent experiments however show that alignment is also possible in simple coil-coil BCPs. In particular, alignment of lamellae was observed in poly(styrene-b-4-vinylpyridine) (PS-P4VP) on cooling across the order-disorder transition at field strengths as low as 1 T, with alignment improving markedly with increasing field strength and decreasing cooling rate. Here we discuss the intrinsic chain anisotropy which drives the observed alignment, and its display as a net microdomain anisotropy due to chain tethering at the block interface. We use in-situ X-ray scattering to study the phase behavior and temperature-, time-, and field- dependent dynamics of magnetic alignment in coil-coil BCPs, highlighting the important roles of chain anisotropy and grain size in alignment. For the right combination of field strength and grain size, we can leverage intrinsic chain anisotropy to magnetically direct self-assembly in other coil-coil systems, including cylinder-forming poly(styrene-b-dimethylsiloxane). Field alignment of PS-P4VP with PEO and other blends provides a route to form functional materials such as nanoporous films and ion conducting polymers.

  13. Degradation analysis of REBCO coils

    International Nuclear Information System (INIS)

    RE-Ba-Cu-O (REBCO) layer-wound coils were operated to investigate their properties under electromagnetic forces in an external magnetic field of up to 17.2 T. While REBCO coils were successfully operated under electromagnetic forces over 200 MPa, some showed degradation after quenching. To develop high-temperature superconducting (HTS) magnets, the reasons for the degradation of REBCO coils should be investigated. In this study, the degraded REBCO coils were carefully rewound. The critical current (Ic) of the rewound REBCO conductor was measured to check the damaged parts in the degraded REBCO coils, and the possible causes for the degradation were discussed. (paper)

  14. Analysis of the factors affecting thermal evolution of hot rolled steel during coil cooling

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The thermal evolution of steel coil during cooling was simulated and investigated by the use of in-house Q-CSP(R) software.The dependence of the thermal evolution of steel coil on cooling methods, temperature distribution of the strip before coiling, coil size and steel grades was also discussed.The study plays a significant role in helping steel makers to better understand and control the cooling process.

  15. GBNV encoded movement protein (NSm) remodels ER network via C-terminal coiled coil domain

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Pratibha; Savithri, H.S., E-mail: bchss@biochem.iisc.ernet.in

    2015-08-15

    Plant viruses exploit the host machinery for targeting the viral genome–movement protein complex to plasmodesmata (PD). The mechanism by which the non-structural protein m (NSm) of Groundnut bud necrosis virus (GBNV) is targeted to PD was investigated using Agrobacterium mediated transient expression of NSm and its fusion proteins in Nicotiana benthamiana. GFP:NSm formed punctuate structures that colocalized with mCherry:plasmodesmata localized protein 1a (PDLP 1a) confirming that GBNV NSm localizes to PD. Unlike in other movement proteins, the C-terminal coiled coil domain of GBNV NSm was shown to be involved in the localization of NSm to PD, as deletion of this domain resulted in the cytoplasmic localization of NSm. Treatment with Brefeldin A demonstrated the role of ER in targeting GFP NSm to PD. Furthermore, mCherry:NSm co-localized with ER–GFP (endoplasmic reticulum targeting peptide (HDEL peptide fused with GFP). Co-expression of NSm with ER–GFP showed that the ER-network was transformed into vesicles indicating that NSm interacts with ER and remodels it. Mutations in the conserved hydrophobic region of NSm (residues 130–138) did not abolish the formation of vesicles. Additionally, the conserved prolines at positions 140 and 142 were found to be essential for targeting the vesicles to the cell membrane. Further, systematic deletion of amino acid residues from N- and C-terminus demonstrated that N-terminal 203 amino acids are dispensable for the vesicle formation. On the other hand, the C-terminal coiled coil domain when expressed alone could also form vesicles. These results suggest that GBNV NSm remodels the ER network by forming vesicles via its interaction through the C-terminal coiled coil domain. Interestingly, NSm interacts with NP in vitro and coexpression of these two proteins in planta resulted in the relocalization of NP to PD and this relocalization was abolished when the N-terminal unfolded region of NSm was deleted. Thus, the NSm

  16. GBNV encoded movement protein (NSm) remodels ER network via C-terminal coiled coil domain

    International Nuclear Information System (INIS)

    Plant viruses exploit the host machinery for targeting the viral genome–movement protein complex to plasmodesmata (PD). The mechanism by which the non-structural protein m (NSm) of Groundnut bud necrosis virus (GBNV) is targeted to PD was investigated using Agrobacterium mediated transient expression of NSm and its fusion proteins in Nicotiana benthamiana. GFP:NSm formed punctuate structures that colocalized with mCherry:plasmodesmata localized protein 1a (PDLP 1a) confirming that GBNV NSm localizes to PD. Unlike in other movement proteins, the C-terminal coiled coil domain of GBNV NSm was shown to be involved in the localization of NSm to PD, as deletion of this domain resulted in the cytoplasmic localization of NSm. Treatment with Brefeldin A demonstrated the role of ER in targeting GFP NSm to PD. Furthermore, mCherry:NSm co-localized with ER–GFP (endoplasmic reticulum targeting peptide (HDEL peptide fused with GFP). Co-expression of NSm with ER–GFP showed that the ER-network was transformed into vesicles indicating that NSm interacts with ER and remodels it. Mutations in the conserved hydrophobic region of NSm (residues 130–138) did not abolish the formation of vesicles. Additionally, the conserved prolines at positions 140 and 142 were found to be essential for targeting the vesicles to the cell membrane. Further, systematic deletion of amino acid residues from N- and C-terminus demonstrated that N-terminal 203 amino acids are dispensable for the vesicle formation. On the other hand, the C-terminal coiled coil domain when expressed alone could also form vesicles. These results suggest that GBNV NSm remodels the ER network by forming vesicles via its interaction through the C-terminal coiled coil domain. Interestingly, NSm interacts with NP in vitro and coexpression of these two proteins in planta resulted in the relocalization of NP to PD and this relocalization was abolished when the N-terminal unfolded region of NSm was deleted. Thus, the NSm

  17. Management of symptomatic venous aneurysm.

    Science.gov (United States)

    Gabrielli, Roberto; Rosati, Maria Sofia; Siani, Andrea; Irace, Luigi

    2012-01-01

    Venous aneurysms (VAs) have been described in quite of all the major veins. They represent uncommon events but often life-threatening because of pulmonary or paradoxical embolism. We describe our twelve patients' series with acute pulmonary emboli due to venous aneurysm thrombosis. Our experience underlines the importance of a multilevel case-by-case approach and the immediate venous lower limbs duplex scan evaluation in pulmonary embolism events. Our data confirm that anticoagulant alone is not effective in preventing pulmonary embolism. We believe that all the VAs of the deep venous system of the extremities should be treated with surgery as well as symptomatic superficial venous aneurysm. A simple excision can significantly improve symptoms and prevent pulmonary embolism. PMID:22566766

  18. Nonruptured intracranial aneurysms: therapeutic recommendations

    International Nuclear Information System (INIS)

    With the development of new diagnostic noninvasive tools an increase in the diagnosis of asymptomatic nonruptured intracranial aneurysms has been shown. Physician and patient now have to decide wether to treat or to follow-up these aneurysms. This paper trys to review and to discuss the literature and to give guidelines for therapeutic decisions. The decision to treat an unruptured intracranial aeurysm must always comprise the individuell factors such as age, life prognosis, neurological status, and the advantages and disdavantages of the considered method. (orig.)

  19. Vortex Dynamics in Cerebral Aneurysms

    CERN Document Server

    Byrne, Greg

    2013-01-01

    We use an autonomous three-dimensional dynamical system to study embedded vortex structures that are observed to form in computational fluid dynamic simulations of patient-specific cerebral aneurysm geometries. These structures, described by a vortex which is enclosed within a larger vortex flowing in the opposite direction, are created and destroyed in phase space as fixed points undergo saddle-node bifurcations along vortex core lines. We illustrate how saddle-node bifurcations along vortex core lines also govern the formation and evolution of embedded vortices in cerebral aneurysms under variable inflow rates during the cardiac cycle.

  20. Septal aneurysm with associated anomalies

    International Nuclear Information System (INIS)

    A 15-year-old boy had a history of a functional systolic murmur with systolic and diastolic murmurs and radiological evidence of left ventricular hypertrophy. The angiorcardiogram demonstrated an aneurysm of the membranous septum, bicuspid aortic valve, dilatation of the left subclavian artery and left common carotid artery. Echocardiography showed a holosystolic prolapse of the mitral valve with mitral insufficiency and a bicuspid aortic valve with insignificant incompetence of the aortic valve. Classical TM mode echocardiography did not show an aneurysm of the membranous septum. (orig.)

  1. Endoluminal placement of stent-graft for the treatment of peripheral saccular aneurysm

    International Nuclear Information System (INIS)

    To determine the therapeutic effect of stent grafting in the treatment of saccular aneurysms of the peripheral artery. Eight patients (M:F=7:1 ; age:22-72(mean, 47) years) with ten saccular aneurysms of the peripheral artery who underwent stent grafting were included in this study. The etiologies of the aneurysms were Behcet's disease in four patients, atherosclerosis in two, trauma in one and'undcertain' in one; they were located at the common iliac artery in three cases, the renal artery in two, the subclavian artery in two, the anterior tibial artery in one, and at both the proximal and distal anastomotic sites of the common carotid-internal carotid bypass graft. In two cases, stent grafting and coils were used to embolize collateral vessels. Post-procedural evaluations involved the use of computerd tomography, Doppler sonography and magnetic resonance imaging. The mean follow-up period was 14.7 (range, 4-36) monthes. The saccular aneurysms were successfully excluded in all cases. Post-procedural angiography revealed minor leakage in two cases, but at follow-up these showed complete exclusion. Follow-up evaluation also revealed complete resolution in five cases and complete thrombosis accompanied by size reduction in three. In patients with aneurysms of the proximal and distal ends of a common carotid-internal carotid bypass graft, total occlusion occurred in the stent graft. Percutaneous stent-graft insertion is an effective and convenient method for the treatment of peripheral arterial aneurysms, and is an alternative to vascular surgery

  2. Endovascular Treatment of a Giant Aneurysm of the Maxillary Artery

    OpenAIRE

    J. A. Stephenson; Panteleimonitis, S; E. Choke; Dennis, M.; Glasby, M.

    2012-01-01

    Aneurysms of the maxillary artery are rare and the majority of the literature refers to false aneurysms. We report the first case of what we believe to be a spontaneous true maxillary artery aneurysm and its endovascular management.

  3. Percutaneous Transabdominal Approach for the Treatment of Endoleaks after Endovascular Repair of Infrarenal Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sun Young; Lee, Do Yun; Lee, Kwang Hun [Severance Hospital, University of Yonsei, Seoul (Korea, Republic of); Won, Jong Yun [Gangnam Severance Hospital, University of Yonsei, Seoul (Korea, Republic of); Choi, Dong Hoon; Shim, Won Heum [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2010-02-15

    The purpose of this study was to evaluate the technical feasibility and clinical efficacy of percutaneous transabdominal treatment of endoleaks after endovascular aneurysm repair. Between 2000 and 2007, six patients with type I (n = 4) or II (n = 2) endoleaks were treated by the percutaneous transabdominal approach using embolization with N-butyl cyanoacrylate with or without coils. Five patients underwent a single session and one patient had two sessions of embolization. The median time between aneurysm repair and endoleak treatment was 25.5 months (range: 0-84 months). Follow-up CT images were evaluated for changes in the size and shape of the aneurysm sac and presence or resolution of endoleaks. The median follow-up after endoleak treatment was 16.4 months (range: 0-37 months). Technical success was achieved in all six patients. Clinical success was achieved in four patients with complete resolution of the endoleak confirmed by follow-up CT. Clinical failure was observed in two patients. One eventually underwent surgical conversion, and the other was lost to follow-up. There were no procedure-related complications. The percutaneous transabdominal approach for the treatment of type I or II endoleaks, after endovascular aneurysm repair, is an alternative method when conventional endovascular methods have failed.

  4. Visceral artery aneurysms: Incidence, management, and outcome analysis in a tertiary care center over one decade

    International Nuclear Information System (INIS)

    To evaluate the incidence, management, and outcome of visceral artery aneurysms (VAA) over one decade. 233 patients with 253 VAA were analyzed according to location, diameter, aneurysm type, aetiology, rupture, management, and outcome. VAA were localized at the splenic artery, coeliac trunk, renal artery, hepatic artery, superior mesenteric artery, and other locations. The aetiology was degenerative, iatrogenic after medical procedures, connective tissue disease, and others. The rate of rupture was much higher in pseudoaneurysms than true aneurysms (76.3 % vs.3.1 %). Fifty-nine VAA were treated by intervention (n = 45) or surgery (n = 14). Interventions included embolization with coils or glue, covered stents, or combinations of these. Thirty-five cases with ruptured VAA were treated on an emergency basis. There was no difference in size between ruptured and non-ruptured VAA. After interventional treatment, the 30-day mortality was 6.7 % in ruptured VAA compared to no mortality in non-ruptured cases. Follow-up included CT and/or MRI after a mean period of 18.0 ± 26.8 months. The current status of the patient was obtained by a structured telephone survey. Pseudoaneurysms of visceral arteries have a high risk for rupture. Aneurysm size seems to be no reliable predictor for rupture. Interventional treatment is safe and effective for management of VAA. (orig.)

  5. Endovascular treatment of type II endoleak following thoracic endovascular aortic repair for thoracic aortic aneurysm: Case report of squeeze technique to reach the aneurysmal sac

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hyun Jung; Kim, Chang Won; Lee, Tae Hong; Song, Seung Hwan; Lee, Chung Won; Chung, Sung Woon [Pusan National University Hospital, School of Medicine, Pusan National University, Busan (Korea, Republic of)

    2014-12-15

    Type II endoleaks are common after thoracic endovascular aortic repair (TEVAR). Various strategies are introduced to manage type II endoleaks, such as the use of coils, plugs, or liquid embolic agents (histoacryl, thrombin, onyx, etc.) through a transarterial approach or a direct puncture of the aneurysmal sac. We herein report a case of a type II endoleak caused by reverse blood flow through intercostal artery after TEVAR which was successfully treated with n-butyl cyanoacrylate (histoacryl)-lipiodol mixture by a squeeze technique to reach the aneurismal sac using a microcatheter.

  6. Endovascular treatment of type II endoleak following thoracic endovascular aortic repair for thoracic aortic aneurysm: Case report of squeeze technique to reach the aneurysmal sac

    International Nuclear Information System (INIS)

    Type II endoleaks are common after thoracic endovascular aortic repair (TEVAR). Various strategies are introduced to manage type II endoleaks, such as the use of coils, plugs, or liquid embolic agents (histoacryl, thrombin, onyx, etc.) through a transarterial approach or a direct puncture of the aneurysmal sac. We herein report a case of a type II endoleak caused by reverse blood flow through intercostal artery after TEVAR which was successfully treated with n-butyl cyanoacrylate (histoacryl)-lipiodol mixture by a squeeze technique to reach the aneurismal sac using a microcatheter.

  7. Calculation method of Tesla coil

    OpenAIRE

    Коломієць, Роман Олександрович

    2015-01-01

    Tesla coil, despite the simplicity of its design may be called one of the least studied electronic devices. The article is an attempt to bring in various experimental results of general theoretical framework, which is the basis of exact calculation method of Tesla coils. Such calculation should be the starting point to create devices based on it. In order to develop such methods were considered the general principles of designing Tesla coil, reviewed the most famous mathematical models of its...

  8. Treatment of intracranial aneurysms by flow diverter devices: Long-term results from a single center

    Energy Technology Data Exchange (ETDEWEB)

    Briganti, Francesco, E-mail: frabriga@unina.it [Unit of Interventional Neuroradiology, Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Napoli, Manuela, E-mail: napoli.manuela@gmail.com [Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Leone, Giuseppe, E-mail: g.leonemd@gmail.com [Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Marseglia, Mariano, E-mail: mariano-marseglia@libero.it [Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Mariniello, Giuseppe, E-mail: giuseppe.mariniello@unina.it [Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Caranci, Ferdinando, E-mail: ferdinando.caranci@unina.it [Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Tortora, Fabio, E-mail: fabiotor@libero.it [Chair of Neuroradiology, “Magrassi Lanzara” Clinical-Surgical Department, Second University of Naples, Viale Colli Aminei 21, 80131 Naples (Italy); Maiuri, Francesco, E-mail: frmaiuri@unina.it [Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy)

    2014-09-15

    Highlights: • We report the long-term results (2–4 years) with Flow Diverter Devices (FDD) from a single-center. • We recommend the use of FDD for large-neck aneurysms of the ICA syphon. • We think that more sophisticate FDD will reduce the incidence of technical adverse events. - Abstract: Objectives: Flow-Diverter Devices (FDD) are a new generation stents designed for the treatment of the intracranial aneurysms. This article reports the long-term results (2–4 years) of this treatment from a single-center. Methods: From November 2008 to January 2012, 35 patients (29 females and 6 males; mean age 53.9 y) with 39 intracranial aneurysms were treated by FDD. Five patients (14.3%) had ruptured aneurysms and 30 (85.7%) had no previous hemorrhage. The procedures were performed in 5 patients (14.3%) with SILK and in 30 (85.7%) with PED. In 3 patients FDDs were used as a second treatment after failure of previous coiling (2 cases) or stenting (one case). The 39 aneurysms were in supraclinoid ICA in 26 (66.7%), cavernous ICA in 2 (5.1%), PCoA in 4 (10.2%), MCA in 5 (12.9%), SCA in 1 (2.6%) and PICA in 1 (2.6%). The aneurysms were small (<10 mm) in 32 cases (82%), large (11–25 mm) in 6 (15.3%) and giant in 1 (2.6%). The occlusion rate according to the aneurysm location, size and neck and the complications were evaluated. Results: Peri-procedural complications included transient dysarthria (2 patients), vasospasm with acute intra-stent aggregation (one), microwire rupture (one) and failure of the stent opening (one). The follow-up was made between 24 and 62 months (mean 41 months); clinical examination and CTA were performed at 1, 3, 6 and 12 months after the procedure. The complete occlusion was confirmed by CTA and DSA. MRI with angiographic-studies was taken every year. Complete occlusion was obtained in 35 aneurysms (92.1%) and subtotal in 3 (7.9%). Complete occlusion occurred at 3 months in 24 cases (68.6%), within 3 and 6 months in 9 (25.7%). The rate and

  9. Treatment of intracranial aneurysms by flow diverter devices: Long-term results from a single center

    International Nuclear Information System (INIS)

    Highlights: • We report the long-term results (2–4 years) with Flow Diverter Devices (FDD) from a single-center. • We recommend the use of FDD for large-neck aneurysms of the ICA syphon. • We think that more sophisticate FDD will reduce the incidence of technical adverse events. - Abstract: Objectives: Flow-Diverter Devices (FDD) are a new generation stents designed for the treatment of the intracranial aneurysms. This article reports the long-term results (2–4 years) of this treatment from a single-center. Methods: From November 2008 to January 2012, 35 patients (29 females and 6 males; mean age 53.9 y) with 39 intracranial aneurysms were treated by FDD. Five patients (14.3%) had ruptured aneurysms and 30 (85.7%) had no previous hemorrhage. The procedures were performed in 5 patients (14.3%) with SILK and in 30 (85.7%) with PED. In 3 patients FDDs were used as a second treatment after failure of previous coiling (2 cases) or stenting (one case). The 39 aneurysms were in supraclinoid ICA in 26 (66.7%), cavernous ICA in 2 (5.1%), PCoA in 4 (10.2%), MCA in 5 (12.9%), SCA in 1 (2.6%) and PICA in 1 (2.6%). The aneurysms were small (<10 mm) in 32 cases (82%), large (11–25 mm) in 6 (15.3%) and giant in 1 (2.6%). The occlusion rate according to the aneurysm location, size and neck and the complications were evaluated. Results: Peri-procedural complications included transient dysarthria (2 patients), vasospasm with acute intra-stent aggregation (one), microwire rupture (one) and failure of the stent opening (one). The follow-up was made between 24 and 62 months (mean 41 months); clinical examination and CTA were performed at 1, 3, 6 and 12 months after the procedure. The complete occlusion was confirmed by CTA and DSA. MRI with angiographic-studies was taken every year. Complete occlusion was obtained in 35 aneurysms (92.1%) and subtotal in 3 (7.9%). Complete occlusion occurred at 3 months in 24 cases (68.6%), within 3 and 6 months in 9 (25.7%). The rate and

  10. Impact of graft composition on the systemic inflammatory response after an elective repair of an abdominal aortic aneurysm

    OpenAIRE

    Baek, Jong Kwan; Kwon, Hyunwook; Ko, Gi-Young; Kim, Min Joo; Han, Youngjin; Chung, Young Soo; Park, Hojong; Kwon, Tae-Won; Cho, Yong-Pil

    2014-01-01

    Purpose The present study aimed to evaluate the risk factors and the role of graft material in the development of an acute phase systemic inflammatory response, and the clinical outcome in patients who undergo endovascular aneurysm repair (EVAR) or open surgical repair (OSR) of an abdominal aortic aneurysm (AAA). Methods We retrospectively evaluated the risk factors and the role of graft material in an increased risk of developing systemic inflammatory response syndrome (SIRS), and the clinic...

  11. Subarachnoid hemorrhage from intracranial aneurysms during pregnancy and the puerperium.

    Science.gov (United States)

    Kataoka, Hiroharu; Miyoshi, Takekazu; Neki, Reiko; Yoshimatsu, Jun; Ishibashi-Ueda, Hatsue; Iihara, Koji

    2013-01-01

    Subarachnoid hemorrhage (SAH) due to the rupture of an intracranial aneurysm (IA) is a rare but serious complication of pregnancy and is responsible for important morbidity and mortality during pregnancy. This study reviewed reports of ruptured IA during pregnancy and the puerperium, and our own cases of ruptured IA in pregnant women. Hemorrhage occurred predominantly during the third trimester of pregnancy, when maternal cardiac output and blood volume increase and reach maximum. Physiological and hormonal changes in pregnancy are likely to affect the risk of IA rupture. Ruptured IAs during pregnancy should be managed based on neurosurgical considerations, and the obstetrical management of women with ruptured IAs should be decided according to the severity of SAH and the gestational age. Emergent cesarean section followed by clipping or coiling of aneurysms is indicated if the maternal condition and the gestational age allow such interventions. Although SAH during pregnancy can result in disastrous outcomes, the necessity of intracranial screening for high-risk pregnant women is still controversial. PMID:23979051

  12. Appearance and impact of post-operative intracranial clips and coils on whole-brain CT angiography and perfusion

    International Nuclear Information System (INIS)

    Background: To evaluate the effect of vascular clips and endovascular coils placed for intracranial aneurysms and arteriovenous malformations on whole-brain computed tomography (CT) angiography and perfusion. Methods: A 320-detector row dynamic volume CT system imaged 11 patients following surgical placement of vascular clips or endovascular coils. The extent of clip and coil subtraction by automated software was evaluated using CT digital subtraction angiography and CT perfusion. Impact on CT perfusion values by retained intracranial devices was compared to age- and gender-matched controls. Results: Clip and coil subtraction on CT angiography was graded as good in 8 and moderate in 3 cases. A residual neck and additional aneurysm were noted in 1 of 11 patients. Post-procedural axial slice level CT perfusion values decreased in reliability with increasing proximity to the metallic devices secondary to beam hardening. However, the intracranial devices did not affect axial slice level CTP values of cerebral blood volume, cerebral blood flow and mean transit time outside of the level of the device. Time to peak values was globally decreased outside of the immediate vascular intervention region. Conclusions: Advances in CT technology have provided clinically useful subtraction of intracranial clips and coils. While CT perfusion values were altered in device subtraction areas and within beam hardening artifact areas; they can provide valuable postoperative information on whole-brain hemodynamics. In selected cases, the combination of CT angiography and whole-brain CT perfusion can offer an alternative to conventional angiography that is a more invasive option.

  13. Infected aortic aneurysm and inflammatory aortic aneurysm. In search of an optimal differential diagnosis

    International Nuclear Information System (INIS)

    Infected aortic aneurysm and inflammatory aortic aneurysm each account for a minor fraction of the total incidence of aortic aneurysm and are associated with periaortic inflammation. Despite the similarity, infected aortic aneurysm generally shows a more rapid change in clinical condition, leading to a fatal outcome; in addition, delayed diagnosis and misuse of corticosteroid or immunosuppressing drugs may lead to uncontrolled growth of microorganisms. Therefore, it is mandatory that detection of aortic aneurysm is followed by accurate differential diagnosis. In general, infected aortic aneurysm appears usually as a saccular form aneurysm with nodularity, irregular configuration; however, the differential diagnosis may not be easy sometimes for the following reasons: symptoms, such as abdominal and/or back pain and fever, and blood test abnormalities, such as elevated C-reactive protein and enhanced erythrocyte sedimentation rate, are common in infected aortic aneurysm, but they are not found infrequently in inflammatory aortic aneurysm; some inflammatory aortic aneurysms are immunoglobulin (Ig) G4-related, but not all of them; the prevalence of IgG4 positivity in infected aortic aneurysm has not been well investigated; enhanced uptake of 18F-fluorodeoxyglucose (FDG) by 18F-FDG-positron emission tomography may not distinguish between inflammation mediated by autoimmunity and that mediated by microorganism infection. Here we discuss the characteristics of these two forms of aortic aneurysm and the points of which we have to be aware before reaching a final diagnosis. (author)

  14. The intracranial aneurysm: cost-effective of the aneurysm intra-artery GDC embolization and the aneurysm incarcerated operation

    International Nuclear Information System (INIS)

    Objective: To evaluate the cost-effectiveness of the aneurysm intra-artery GDC embolization and the aneurysm clapping of intracranial aneurysm, and to give the instruction for the clinical practice. Methods: A case control study (1 vs. 1) was developed to evaluate the cost in hospital, the cost for return visit and the Quality-adusted Life-Year (QALY) and lifetime costs of the intra-artery GDC embolization and the aneurysm clapping of intraeranial aneurysm, under the matching of the age, sex, living place, the size and place of the aneurysm, and the Hunt and Hess score. Clinically effectiveness dates were derived from the medical records. Cost dates were derived from follow-up by telephones or letters. The correlation analysis was done with the SPSS 13.0. Results: The cost in hospital in AC group was (54 945±16 946)RMBs, which was higher than the ones in AE group (63 768±12 665) RMBs, (t=1.71, P0.05). Conclusion: The results suggest that the two therapies have no difference in cost effective rate. Considering the physical and mental loss, the aneurysm intra-arteu GDC embolization was better than the aneurysm clapping for the patients with aneurysm that diameter less than 25 mm. (authors)

  15. Isolated iliac artery aneurysms with associated hydronephrosis.

    LENUS (Irish Health Repository)

    O'Driscoll, D

    2012-02-03

    An isolated iliac artery aneurysm is where there is aneurysmal dilatation of one or more branches of the iliac system, with no associated dilatation of the aorta. Such aneurysms are rare and comprise 1% of all intra-abdominal aneurysms. The signs and symptoms of such an aneurysm are influenced by its concealed location within the bony pelvis. Awareness of these special characteristics improves the chances of early diagnosis and proper treatment before possible rupture. We present the clinical and radiological features of three such aneurysms. Ultrasound was the first imaging modality to be performed. Ipsilateral hydronephrosis was demonstrated in each case, this lead to imaging the pelvis and the correct diagnosis. We review the clinical and radiological literature and conclude that the pelvis should be imaged in all cases of unexplained hydronephrosis.

  16. Triple Halo Coil: Development and Comparison with Other TMS Coils

    Science.gov (United States)

    Rastogi, Priyam; Hadimani, Ravi; Jiles, David

    Transcranial Magnetic Stimulation (TMS) is a non-invasive stimulation technique that can be used for the treatment of various neurological disorders such as Parkinson's Disease, PTSD, TBI and anxiety by regulating synaptic activity. TMS is FDA approved for the treatment of major depressive disorder. There is a critical need to develop deep TMS coils that can stimulate deeper regions of the brain without excessively stimulating the cortex in order to provide an alternative to surgical methods. We have developed a novel multi-coil configuration called ``Triple Halo Coil'' (THC) that can stimulate deep brain regions. Investigation of induced electric and magnetic field in these regions have been achieved by computer modelling. Comparison of the results due to THC configuration have been conducted with other TMS coils such as ``Halo Coil'', circular coil and ``Figure of Eight'' coil. There was an improvement of more than 15 times in the strength of magnetic field, induced by THC configuration at 10 cm below the vertex of the head when compared with the ``Figure of Eight'' coil alone. Carver Charitable Trust.

  17. Therapeutic algorithm to treat common iliac artery aneurysms by endovascular means.

    Science.gov (United States)

    Panuccio, Giuseppe; Torsello, Giovanni F; Torsello, Giovanni B; Donas, Konstantinos P

    2016-10-01

    Use of endovascular means is gaining ever greater acceptance in the treatment of aorto-iliac aneurysms. Especially, the treatment of patients with common iliac aneurysms (CIAs) may be very challenging due to the complexity of the underlying disease with often involvement of the hypogastric artery. Additionally, the variety of endovascular therapeutic options such as the use of iliac branch devices, parallel grafts, the bell-bottom technique or coil embolization of the hypogastric artery and overstenting of the origin represents significant limitation regarding the presentation of a clear and robust endovascular therapeutic algorithm. Aim of the present article was the demonstration of the institutional experience with the endovascular management of CIAs in order to provide a clinical recommendation and algorithm. PMID:27406396

  18. Aneurysm miRNA Signature Differs, Depending on Disease Localization and Morphology

    Directory of Open Access Journals (Sweden)

    Albert Busch

    2016-01-01

    Full Text Available Limited comprehension of aneurysm pathology has led to inconclusive results from clinical trials. miRNAs are key regulators of post-translational gene modification and are useful tools in elucidating key features of aneurysm pathogenesis in distinct entities of abdominal and popliteal aneurysms. Here, surgically harvested specimens from 19 abdominal aortic aneurysm (AAA and 8 popliteal artery aneurysm (PAA patients were analyzed for miRNA expression and histologically classified regarding extracellular matrix (ECM remodeling and inflammation. DIANA-based computational target prediction and pathway enrichment analysis verified our results, as well as previous ones. miRNA-362, -19b-1, -194, -769, -21 and -550 were significantly down-regulated in AAA samples depending on degree of inflammation. Similar or inverse regulation was found for miR-769, 19b-1 and miR-550, -21, whereas miR-194 and -362 were unaltered in PAA. In situ hybridization verified higher expression of miR-550 and -21 in PAA compared to AAA and computational analysis for target genes and pathway enrichment affirmed signal transduction, cell-cell-interaction and cell degradation pathways, in line with previous results. Despite the vague role of miRNAs for potential diagnostic and treatment purposes, the number of candidates from tissue signature studies is increasing. Tissue morphology influences subsequent research, yet comparison of distinct entities of aneurysm disease can unravel core pathways.

  19. Gender differences in cerebral aneurysm location

    OpenAIRE

    Ali Jourabchi Ghods; Demetrius eLopes; Michael eChen

    2012-01-01

    Background and Purpose: A limited number of studies consisting predominantly of ruptured aneurysms have looked at differences in anatomical distribution of aneurysms between male and females. Unlike all other causes of stroke, subarachnoid-hemorrhages (SAH) occur more often in women and are thought to be a result of both hormonal influences and variation in wall shear stress (WSS). This paper retrospectively looks at a cohort of largely unruptured intracranial aneurysms to determine if there ...

  20. Portal Vein Aneurysm Presenting with Obstructive Jaundice

    OpenAIRE

    Chandana Lall; Sadhna Verma; Rajesh Gulati; Puneet Bhargava

    2012-01-01

    To the best of our knowledge, a portal vein aneurysm presenting with obstructive jaundice has not been reported in the literature. The preferred treatment for these aneurysms is surgical and a shunting procedure should be considered in cases with portal hypertension to preserve portal vein flow when portal hypertension is present or is secondary to the aneurysm itself. In our case, due to patient′s advanced age and co-morbidities, an endoscopic biliary stent was placed which led to successful...

  1. Non-enhanced MR imaging of cerebral aneurysms: 7 Tesla versus 1.5 Tesla.

    Directory of Open Access Journals (Sweden)

    Karsten H Wrede

    Full Text Available PURPOSE: To prospectively evaluate 7 Tesla time-of-flight (TOF magnetic resonance angiography (MRA in comparison to 1.5 Tesla TOF MRA and 7 Tesla non-contrast enhanced magnetization-prepared rapid acquisition gradient-echo (MPRAGE for delineation of unruptured intracranial aneurysms (UIA. MATERIAL AND METHODS: Sixteen neurosurgical patients (male n = 5, female n = 11 with single or multiple UIA were enrolled in this trial. All patients were accordingly examined at 7 Tesla and 1.5 Tesla MRI utilizing dedicated head coils. The following sequences were obtained: 7 Tesla TOF MRA, 1.5 Tesla TOF MRA and 7 Tesla non-contrast enhanced MPRAGE. Image analysis was performed by two radiologists with regard to delineation of aneurysm features (dome, neck, parent vessel, presence of artifacts, vessel-tissue-contrast and overall image quality. Interobserver accordance and intermethod comparisons were calculated by kappa coefficient and Lin's concordance correlation coefficient. RESULTS: A total of 20 intracranial aneurysms were detected in 16 patients, with two patients showing multiple aneurysms (n = 2, n = 4. Out of 20 intracranial aneurysms, 14 aneurysms were located in the anterior circulation and 6 aneurysms in the posterior circulation. 7 Tesla MPRAGE imaging was superior over 1.5 and 7 Tesla TOF MRA in the assessment of all considered aneurysm and image quality features (e.g. image quality: mean MPRAGE7T: 5.0; mean TOF7T: 4.3; mean TOF1.5T: 4.3. Ratings for 7 Tesla TOF MRA were equal or higher over 1.5 Tesla TOF MRA for all assessed features except for artifact delineation (mean TOF7T: 4.3; mean TOF1.5T 4.4. Interobserver accordance was good to excellent for most ratings. CONCLUSION: 7 Tesla MPRAGE imaging demonstrated its superiority in the detection and assessment of UIA as well as overall imaging features, offering excellent interobserver accordance and highest scores for all ratings. Hence, it may bear the potential to serve as a

  2. In vivo visualization and analysis of 3-D hemodynamics in cerebral aneurysms with flow-sensitized 4-D MR imaging at 3 T

    International Nuclear Information System (INIS)

    Blood-flow patterns and wall shear stress (WSS) are considered to play a major role in the development and rupture of cerebral aneurysms. These hemodynamic aspects have been extensively studied in vitro using geometric realistic aneurysm models. The purpose of this study was to evaluate the feasibility of in vivo flow-sensitized 4-D MR imaging for analysis of intraaneurysmal hemodynamics. Five cerebral aneurysms were examined using ECG-gated, flow-sensitized 4-D MR imaging at 3 T in three patients. Postprocessing included quantification of flow velocities, visualization of time-resolved 2-D vector graphs and 3-D particle traces, vortical flow analysis, and estimation of WSS. Flow patterns were analyzed in relation to aneurysm geometry and aspect ratio. Magnitude, spatial and temporal evolution of vortical flow differed markedly among the aneurysms. Particularly unstable vortical flow was demonstrated in a wide-necked parophthalmic ICA aneurysm (high aspect ratio). Relatively stable vortical flow was observed in aneurysms with a lower aspect ratio. Except for a wide-necked cavernous ICA aneurysm (low aspect ratio), WSS was reduced in all aneurysms and showed a high spatial variation. In vivo flow-sensitized 4-D MR imaging can be applied to analyze complex patterns of intraaneurysmal flow. Flow patterns, distribution of flow velocities, and WSS seem to be determined by the vascular geometry of the aneurysm. Temporal and spatial averaging effects are drawbacks of the MR-based analysis of flow patterns as well as the estimation of WSS, particularly in small aneurysms. Further studies are needed to establish a direct link between definitive flow patterns and different aneurysm geometries. (orig.)

  3. Natural history of giant intracranial aneurysms

    International Nuclear Information System (INIS)

    The outcome of a consecutive series of 28 patients with giant aneurysm who had been followed without surgery from one month to 12 years after the diagnosis was made, are presented with reviewing their radiological and clinical features. Symptoms and signs were directly or indirectly attributable to the intracranial mass effect and nine patients (32 %) presented subarachnoid hemorrhage. Subarachnoid hemorrhage was frequently associated with intraventricular or intracerebral hemorrhage, a poor clinical grading at admission and a high mortality. Subarachnoid hemorrhage was most often recorded from the giant aneurysm at the supraclinoid portion of the internal carotid artery and the vertebro-basilar artery, but the rupture from the intracavernous giant aneurysm, completely thrombosed giant aneurysm and the fusiform type of giant aneurysm was rare. The mortality rate in 28 cases for the above follow up period was 46 % (13 in 28 cases) and major morbidity occured in 11 % (3 in 28 cases). The above outcome of non operated giant aneurysm cases may justify the surgical management of the giant aneurysm, but as the intracavernous giant aneurysm and thrombosed giant aneurysm are relatively harmless, surgical indication should be carefully decided, especially in the older patients. (author)

  4. Angiographic Findings In Patients With Cerebral Aneurysm

    Directory of Open Access Journals (Sweden)

    Miri S M

    2004-09-01

    Full Text Available Background: This investigation was conducted in order to study angiographic findings in patients with cerebral aneurysm. Materials and Methods: The study conducted on 136 cases of ruptured cerebral aneurysms between 1995-2000 confirmed by means of 4-vessel cerebral angiography to get an insight to racial, geographic and environmental factors predisposing to the occurrence of subarachnoid hemorrhage and aneurysm formation. Results: The data analysis revealed the following results: 58% of the population comprised of male and 42% female with a mean age of 46 years. 89% of the aneurysms were found in the anterior circulation and 11% occurred in the posterior cerebral circulation. The most common site in both the sexes was the anterior communicating artery. 9.6% of the patients displayed two separate aneurysms. 5.2% of the aneurysms were found to be giant aneurysms and 3% of the patients had fusiform aneurysms. Conclusion: The low average age, a predilection in male population and the prevalence of aneurysms at carotid and middle cerebral artery bifurcation and the distal branches of anterior cerebral artery and a higher incidence of anterior communicating artery in women were the findings observed in this study.

  5. Microsurgical clipping of an unruptured lenticulostriate aneurysm.

    Science.gov (United States)

    Kalani, M Yashar S; Martirosyan, Nikolay L; Nakaji, Peter; Spetzler, Robert F

    2012-11-01

    Aneurysms of the lenticulostriate artery have been associated with hypertension, vasculopathy, tumors, and arteriovenous malformations. Although several cases of microsurgical treatment of ruptured lenticulostriate artery aneurysms have been reported, to our knowledge there is no published case of microsurgical treatment of an unruptured lenticulostriate artery aneurysm. We report a 66-year-old woman with a history of moyamoya disease, previously treated with a right-sided middle cerebral artery-to-superficial temporal artery bypass who presented with an unruptured aneurysm of a lenticulostriate artery. We report successful microsurgical treatment of this rare lesion and discuss the rationale for our treatment strategy. PMID:22925414

  6. CCHMM_PROF: a HMM-based coiled-coil predictor with evolutionary information

    DEFF Research Database (Denmark)

    Bartoli, Lisa; Fariselli, Piero; Krogh, Anders; Casadio, Rita

    2009-01-01

    MOTIVATION: The widespread coiled-coil structural motif in proteins is known to mediate a variety of biological interactions. Recognizing a coiled-coil containing sequence and locating its coiled-coil domains are key steps towards the determination of the protein structure and function. Different...

  7. Endovascular treatment of thoracic aorta aneurysm and dissection

    International Nuclear Information System (INIS)

    Full text: The aim is to give up to date information about modern endovascular treatment of aortic pathology Dissection and aneurysms of the aorta are life threatening condition requiring in most of the cases prompt surgical or endovascular treatment because of the poor natural evolution. Purpose: to assess the immediate and 1-year outcome of endovascular treatment in broad spectrum of acute and subacute aortic syndrome during the last 3 years (November 2012 - August 2015) in City Clinic (Sofia, Bulgaria). We performed endovascular treatment of 47 patients (43 men, 4 women) at average age 54 y. with dissection (24) and aneurysms (23) of the aortic arch and thoracic aorta (in 5 emergent treatment was performed for aortic rupture). All patients were treated with minimal surgical femoral approach. In 4 (9%) of them initial carotid to carotid bypass was performed in order to provide a sufficient landing zone for the endograft implantation.the last 9 patients (19%) were treated without general anesthesia with either deep sedation or epidural anesthesia. Results: In all patients successful endograft implantation was achieved. Additional stent-graft or open cell stent was implanted in 4 cases in order to centralize the flow in the compressed true lumen. In 5 cases additional vascular plug or large coil was delivered in the left subclavian arteryostium in order to interrupt retrograde aneurysm or false lumen filling. Complications: 30 days mortality-2.2%, neurologic disorders (4.4%). one year survival- 45 (90.5%). 3 and 6 mo control CT scan showed no migration of the graft in 100%, full false lumen isolation in 19 out of 24 dissections (80%) and aneurysm free of expansion in 20 out of 23 (86%), patent carotid bay-pass graft in 4 of 4 (100%). This one center study showed excellent immediate and 1 year clinical and device results from endovascular repair of potentially fatal disease. Endovascular treatment is a method of choice for broad spectrum of aortic pathology

  8. Dynamics of the Coiled-Coil Unfolding Transition of Myosin Rod Probed by Dissipation Force Spectrum

    OpenAIRE

    Taniguchi, Yukinori; Khatri, Bhavin S.; Brockwell, David J.; Paci, Emanuele; Kawakami, Masaru

    2010-01-01

    The motor protein myosin II plays a crucial role in muscle contraction. The mechanical properties of its coiled-coil region, the myosin rod, are important for effective force transduction during muscle function. Previous studies have investigated the static elastic response of the myosin rod. However, analogous to the study of macroscopic complex fluids, how myosin will respond to physiological time-dependent loads can only be understood from its viscoelastic response. Here, we apply atomic f...

  9. Superconducting poloidal coils for STARFIRE commercial reactor

    International Nuclear Information System (INIS)

    STARFIRE is considered to be the tenth commercial tokamak power plant. A preliminary design study on its superconducting poloidal coil system is presented. Key features of the design studies are: the elimination of the ohmic heating coil; the trade-off studies of the equilibrium field coil locations; and the development of a conceptual design for the superconducting equilibrium field coils. Described are the 100 kA cryostable conductor design, the coil structure, and evaluation of the coil forces

  10. Time evolution and hemodynamics of cerebral aneurysms

    Science.gov (United States)

    Sforza, Daniel M.; Putman, Christopher; Tateshima, Satoshi; Viñuela, Fernando; Cebral, Juan

    2011-03-01

    Cerebral aneurysm rupture is a leading cause of hemorrhagic strokes. Because they are being more frequently diagnosed before rupture and the prognosis of subarachnoid hemorrhage is poor, clinicians are often required to judge which aneurysms are prone to progression and rupture. Unfortunately, the processes of aneurysm initiation, growth and rupture are not well understood. Multiple factors associated to these processes have been identified. Our goal is to investigate two of them, arterial hemodynamics (using computational fluid dynamics) and the peri-aneurysmal environment, by studying a group of growing cerebral aneurysms that are followed longitudinally in time. Six patients with unruptured untreated brain aneurysms which exhibited growth during the observation period were selected for the study. Vascular models of each aneurysm at each observation time were constructed from the corresponding computed tomography angiography (CTA) images. Subsequently, models were aligned, and geometrical differences quantified. Blood flow was modeled with the 3D unsteady incompressible Navier-Stokes equation for a Newtonian fluid, and wall shear stress distribution and flow patterns were calculated and visualized. Analysis of the simulations and changes in geometry revealed asymmetric growth patterns and suggests that areas subject to vigorous flows, i.e. relative high wall shear stress and concentrated streamlines patterns; correspond to regions of aneurysm growth. Furthermore, in some cases the geometrical evolution of aneurysms is clearly affected by contacts with bone structures and calcifications in the wall, and as a consequence the hemodynamics is greatly modified. Thus, in these cases the peri-aneurysmal environment must be considered when analyzing aneurysm evolution.

  11. Coronary artery aneurysm: case report

    OpenAIRE

    Burkhart Harold M; Everett Jeffrey E

    2008-01-01

    Abstract Introduction Aneurysms of the left main coronary artery are rare with an incidence of 0.1% in large angiographic series. The majority are atherosclerotic in origin. Other causes include connective tissue disorders, trauma, vasculitis, congenital, mycotic and idiopathic. The primary complication is myocardial ischemia or infarction, with rupture being rare. Treatment options include anticoagulation, custom made covered stents, reconstruction, resection, and exclusion with bypass. Case...

  12. Traumatic intracranial aneurysms in children

    International Nuclear Information System (INIS)

    To describe the imaging findings of traumatic intracranial aneurysms (TICA) in children. Five boys aged 3-15 (mean, 7) years with surgically confirmed TICA were included in this study. All had a history of nonpenetrating head trauma, and they underwent precontrast CT imaging immediately after the injury and follow-up CR or MRI. In all cases, angiography revealed the presence of aneurysms, which at surgery were shown to be pseudoaneurysms with sever adhesions. Angiography demonstrated that all aneurysms were located in the anterior cerebral artery (ACA) or its branches. The precise locations were the A2 segment of the ACA, the site of origin of the callosomarginal artery or its first branch, or of the anterior internal frontal artery, or between the first and second branch of the pericallosal artery. In all patients, precontrast CT performed immediately after trauma depicted subarachnoid hemorrhage (SAH) in the anterior interhemispheric fissure (AIHF). Follow-up precontrast CT showed nodular high density around the anterior falx in three, recurrent SAH in the AIHF in two, and intracerebral hemorrhage (ICH) with intraventricular hemorrhage in two. In two patients with a nodular high-density lesion, nodular enhancement was demonstrated at postcontrast CT, and in one, follow-up MRI revealed a nodular signal void around the anterior falx; nodular enhancement was seen at postcontrast imaging, and MR angiogram depicted a saccular aneurysm. In one patient, MRI demonstrated infarction in the caudate nucleus and ACA territory. If, after head injury, an area of nodular high density is revealed by CT, or a signal void by MRI, or is SAH or ICH is present around the anterior falx, the possibility of TICA should be considered

  13. Idiopathic giant right atrial aneurysm

    International Nuclear Information System (INIS)

    A 2-year-old boy with an incidental finding of massive cardiomegaly on a chest X-ray was diagnosed with a giant right atrial aneurysm upon further investigation with echocardiography. The patient underwent successful surgical reduction of the right atrium and closure of the patent foramen ovale to prevent thromboembolic complications and to lower the risk of atrial arrhythmias. The resected atrium had paper-thin walls and pathological features of interstitial fibrosis with endocardial thickening

  14. Hemoglobin induces monocyte recruitment and CD163-macrophage polarization in abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Rubio-Navarro, Alfonso; Amaro Villalobos, Juan Manuel; Lindholt, Jes S;

    2015-01-01

    BACKGROUND: Increased hemoglobin (Hb) accumulation was reported in abdominal aortic aneurysms (AAAs). CD163 is a macrophage receptor involved in tissue Hb clearance, however its role in AAA has not been reported. We investigated the role of Hb on monocyte recruitment and differentiation towards C...

  15. Intracranial dissecting and saccular aneurysms in polycystic kidney disease.

    Science.gov (United States)

    Kulla, L; Deymeer, F; Smith, T W; Weiner, M; Mullins, T F

    1982-12-01

    A young man with polycystic kidney disease was seen initially with an brain-stem infarction. Postmortem examination disclosed a dissecting aneurysm of the basilar artery and a saccular aneurysm of the right vertebral artery. Dissecting intracranial aneurysms rarely are associated with saccular aneurysms and, to our knowledge, have not been reported in association with polycystic kidney disease. PMID:7138321

  16. Perioperative Variables Contributing to the Rupture of Intracranial Aneurysm: An Update

    Directory of Open Access Journals (Sweden)

    Tumul Chowdhury

    2013-01-01

    Full Text Available Background. Perioperative aneurysm rupture (PAR is one of the most dreaded complications of intracranial aneurysms, and approximately 80% of nontraumatic SAHs are related to such PAR aneurysms. The literature is currently scant and even controversial regarding the issues of various contributory factors on different phases of perioperative period. Thus this paper highlights the current understanding of various risk factors, variables, and outcomes in relation to PAR and try to summarize the current knowledge. Method. We have performed a PubMed search (1 January 1991–31 December 2012 using search terms including “cerebral aneurysm,” “intracranial aneurysm,” and “intraoperative/perioperative rupture.” Results. Various risk factors are summarized in relation to different phases of perioperative period and their relationship with outcome is also highlighted. There exist many well-known preoperative variables which are responsible for the highest percentage of PAR. The role of other variables in the intraoperative/postoperative period is not well known; however, these factors may have important contributory roles in aneurysm rupture. Preoperative variables mainly include natural course (age, gender, and familial history as well as the pathophysiological factors (size, type, location, comorbidities, and procedure. Previously ruptured aneurysm is associated with rupture in all the phases of perioperative period. On the other hand intraoperative/postoperative variables usually depend upon anesthesia and surgery related factors. Intraoperative rupture during predissection phase is associated with poor outcome while intraoperative rupture at any step during embolization procedure imposes poor outcome. Conclusion. We have tried to create such an initial categorization but know that we cannot scale according to its clinical importance. Thorough understanding of various risk factors and other variables associated with PAR will assist in better

  17. Spontaneous Thrombosis in Giant Aneurysm of the Anterior Communicating Artery Complex in Pediatric Age: Five-Year Follow-Up

    Directory of Open Access Journals (Sweden)

    Vítor M. Gonçalves

    2014-01-01

    Full Text Available Intracranial aneurysms are rare in the pediatric population, especially in infancy, representing less than 1% of all aneurysms. In this age group, they are more frequent at the carotid bifurcation and in the posterior circulation, with a greater number of giant aneurysms and spontaneous aneurysm thrombosis when compared with the adults. They are life-threatening, and, therefore, early investigation, characterization of the lesion, and treatment are essential. The appropriate management depends on the child’s condition, aneurysm characteristics, and the experience of a multidisciplinary team. Noninvasive and radiation-free imagiological studies play an important role in the diagnosis and follow-up of these young patients. We present the case of a 3-month-old boy with an intracranial hemorrhage secondary to the rupture of a giant aneurysm of the anterior communicating artery complex, with spontaneous thrombosis, which is a rare situation due to its location. A conservative approach was assumed and noninvasive evolutive imagiological studies revealed a reduction in the thrombosed aneurysm size and no signs of recanalization. The child recovered to his baseline neurological condition and has had no rehemorrhage until 5 years of follow-up.

  18. Bilateral Intracavernous Carotid Artery Aneurysms Presenting as Diplopia in a Young Patient

    Directory of Open Access Journals (Sweden)

    Nikolaos Kopsachilis

    2013-01-01

    Full Text Available Introduction. Bilateral intracavernous carotid artery aneurysms (ICAAs are extremely rare and difficult to treat. Case Report. A 26-year-old female presented in our clinic with acute diplopia due to oculomotor nerve palsy on the left side. Magnetic resonance imaging of the brain showed two heterogeneously enhanced masses indicating bilateral ICAA. An endovascular coil embolization was performed on the left side successfully, resulting in resolution of her symptoms. Conclusion. Thorough systemic evaluation in young patients with diplopia can reveal life-threatening underlying pathology and prevent major complications.

  19. Hepatobiliary fascioliasis with multiple aneurysms and active bleeding: A case report

    International Nuclear Information System (INIS)

    A 52-year-old woman visited our institution with upper abdominal pain which had lasted for the past two days. Laboratory tests revealed mild leukocytosis, decreased serum hemoglobin, and peripheral blood eosinophilia. CT scans showed multiple ill-defined, hypodense lesions in the peripheral areas of both hepatic lobes and active bleeding with a subcapsular hematoma in the right hepatic lobe. Angiography also showed active bleeding in the right hepatic lobe with multiple aneurysms, so a transarterial coil embolization was performed to stop the bleeding. The endoscopic retrograde cholangiopancreatography revealed several moving flat flukes in the common bile duct, which were pathologically confirmed as Fasciola hepatica.

  20. Hepatobiliary fascioliasis with multiple aneurysms and active bleeding: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Soo Young; Kim Jae Woon; Jang, Jae Cheon [Dept. of Radiology, College of Medicine, Yeungnam University, Daegu (Korea, Republic of)

    2015-04-15

    A 52-year-old woman visited our institution with upper abdominal pain which had lasted for the past two days. Laboratory tests revealed mild leukocytosis, decreased serum hemoglobin, and peripheral blood eosinophilia. CT scans showed multiple ill-defined, hypodense lesions in the peripheral areas of both hepatic lobes and active bleeding with a subcapsular hematoma in the right hepatic lobe. Angiography also showed active bleeding in the right hepatic lobe with multiple aneurysms, so a transarterial coil embolization was performed to stop the bleeding. The endoscopic retrograde cholangiopancreatography revealed several moving flat flukes in the common bile duct, which were pathologically confirmed as Fasciola hepatica.

  1. Improved Sensing Coils for SQUIDs

    Science.gov (United States)

    Penanen, Konstantin; Hahn, Inseob; Eom, Byeong Ho

    2007-01-01

    An improvement in the design and fabrication of sensing coils of superconducting quantum interference device (SQUID) magnetometers has been proposed to increase sensitivity. It has been estimated that, in some cases, it would be possible to increase sensitivity by about half or to reduce measurement time correspondingly. The pertinent aspects of the problems of design and fabrication can be summarized as follows: In general, to increase the sensitivity of a SQUID magnetometer, it is necessary to maximize the magnetic flux enclosed by the sensing coil while minimizing the self-inductance of this coil. It is often beneficial to fabricate the coil from a thicker wire to reduce its self-inductance. Moreover, to optimize the design of the coil with respect to sensitivity, it may be necessary to shape the wire to other than a commonly available circular or square cross-section. On the other hand, it is not practical to use thicker superconducting wire for the entire superconducting circuit, especially if the design of a specific device requires a persistent-current loop enclosing a remotely placed SQUID sensor. It may be possible to bond a thicker sensing-coil wire to thinner superconducting wires leading to a SQUID sensor, but it could be difficult to ensure reliable superconducting connections, especially if the bonded wires are made of different materials. The main idea is to mold the sensing coil in place, to more nearly optimum cross sectional shape, instead of making the coil by winding standard pre-fabricated wire. For this purpose, a thin superconducting wire loop that is an essential part of the SQUID magnetometer would be encapsulated in a form that would serve as a mold. A low-melting-temperature superconducting metal (e.g., indium, tin, or a lead/tin alloy) would be melted into the form, which would be sized and shaped to impart the required cross section to the coil thus formed.

  2. Analysis of slipstream flow in two ruptured intracranial cerebral aneurysms.

    Science.gov (United States)

    Imbesi, S G; Kerber, C W

    1999-10-01

    Replicas of ruptured posterior communicating and basilar artery aneurysms were created from cadaveric specimens and then were placed in a circuit of pulsating non-Newtonian fluid. Individual fluid slipstreams were opacified with isobaric dyes, and images were recorded on film. The slipstreams entered the distal aneurysm neck with impact against the distal lateral wall of the aneurysm. They then swirled slowly in a reverse vortical pattern within the aneurysm sac. Fluid exited the aneurysm at the proximal neck. The flow pattern clearly shows the impact zone of entering slipstreams (the point of aneurysm rupture) and provides information pertaining to aneurysm growth and formation. PMID:10543644

  3. Update on diagnosis and treatment of cardiac pseudo aneurysm

    International Nuclear Information System (INIS)

    Echocardiography is an essential tool in the diagnosis of pseudo aneurysm. It has been the most studied in diagnosing this condition.The M, two-dimensional and Doppler apply to reach a correct diagnosis of ventricular pseudo aneurysm. The use of this imaging technique allows noninvasive detection of asymptomatic or postoperative pseudo aneurysms after M mode used to diagnose a pseudo aneurysm to recognize an echo-free space in the posterior wall of the left ventricle. In 1980, Catherwood et al used to compare the two-dimensional echo pseudo aneurysm and a true aneurysm cavity demonstrated pseudo aneurysm globular and discontinuity of the ventricular myocardium

  4. Migraine before rupture of intracranial aneurysms

    DEFF Research Database (Denmark)

    Lebedeva, Elena R; Gurary, Natalia M; Sakovich, Vladimir P;

    2013-01-01

    Rupture of a saccular intracranial aneurysm (SIA) causes thunderclap headache but it remains unclear whether headache in general and migraine in particular are more prevalent in patients with unruptured SIA.......Rupture of a saccular intracranial aneurysm (SIA) causes thunderclap headache but it remains unclear whether headache in general and migraine in particular are more prevalent in patients with unruptured SIA....

  5. Two cases of giant serpentine aneurysm.

    Science.gov (United States)

    Kumabe, T; Kaneko, U; Ishibashi, T; Kaneko, K; Uchigasaki, S

    1990-06-01

    Giant serpentine aneurysm (GSA) is an entity defined on radiological and pathological grounds as a giant, partially thrombosed aneurysm containing tortuous vascular channels. We have had the opportunity to study two patients with GSAs, which has allowed for a complete comparative anatomical and radiological study. This report emphasizes the etiology of the GSAs. Twenty-two patients with GSAs have been reported in the literature, of which pathological studies were done in 10. In most of these, the aneurysm was found to be filled with an organized thrombus, but in our patients the aneurysm was filled with relatively new clot. The aneurysm enlarged and a change in the tortuous vascular channel was observed over a period of 1 year in the first patient, whereas a globoid aneurysm developed into a GSA in the brief period of just 2 weeks in the second patient. This rapid transformation of a globoid aneurysm into a GSA is of particular interest when the etiology of GSAs is considered. Our patients therefore shed some interesting light on the possible pathophysiology of GSAs. That is, the bloodstream may change dynamically in a giant aneurysm and may become a serpentine channel under conditions that lead to a "Coanda effect." PMID:2362659

  6. Cardiovascular syphilis with coronary stenosis and aneurysm.

    Science.gov (United States)

    Tewari, Satyendra; Moorthy, Nagaraja

    2014-01-01

    Cardiovascular manifestations of tertiary syphilis include aortitis, aortic root dilation, aneurysm formation, aortic regurgitation, and coronary ostial stenosis. Coronary ostial lesions have been detected in as many as 26% of patients with syphilitic aortitis. However nonostial coronary stenosis and coronary aneurysms in same patient is rarely described in cardiovascular syphilis. PMID:25634420

  7. Dynamic allostery of protein alpha helical coiled-coils

    OpenAIRE

    Hawkins, R. J.; Mcleish, T.C.B.

    2005-01-01

    Alpha helical coiled-coils appear in many important allosteric proteins such as the dynein molecular motor and bacteria chemotaxis transmembrane receptors. As a mechanism for transmitting the information of ligand binding to a distant site across an allosteric protein, an alternative to conformational change in the mean static structure is an induced change in the pattern of the internal dynamics of the protein. We explore how ligand binding may change the intramolecular vibrational free ener...

  8. ASTROMAG coil cooling study

    Science.gov (United States)

    Maytal, Ben-Zion; Vansciver, Steven W.

    1990-01-01

    ASTROMAG is a planned particle astrophysics magnetic facility. Basically it is a large magnetic spectrometer outside the Earth's atmosphere for an extended period of time in orbit on a space station. A definition team summarized its scientific objectives assumably related to fundamental questions of astrophysics, cosmology, and elementary particle physics. Since magnetic induction of about 7 Tesla is desired, it is planned to be a superconducting magnet cooled to liquid helium 2 temperatures. The general structure of ASTROMAG is based on: (1) two superconducting magnetic coils, (2) dewar of liquid helium 2 to provide cooling capability for the magnets; (3) instrumentation, matter-anti matter spectrometer (MAS) and cosmic ray isotope spectrometer (CRIS); and (4) interfaces to the shuttle and space station. Many configurations of the superconducting magnets and the dewar were proposed and evaluated, since those are the heart of the ASTROMAG. Baseline of the magnet configuration and cryostat as presented in the phase A study and the one kept in mind while doing the present study are presented. ASTROMAG's development schedule reflects the plan of launching to the space station in 1995.

  9. Disappearing Saccular Intracranial Aneurysms: Do They Really Disappear?

    OpenAIRE

    Jayakumar, P. N.; Ravishankar, S.; Balasubramaya, K.S.; Chavan, R.; Goyal, G

    2007-01-01

    Evolution and natural history of cerebral aneurysms is a dynamic process. Spontaneous regression in size or complete disappearance of an aneurysm is a known phenomenon, more commonly noted in giant intracranial aneurysms. However, reappearance or regrowth of such aneurysms is rare with few anecdotal reports. We report a series of four cases including one giant aneurysm, which either disappeared or regressed on sequential angiograms. Regrowth or reappearance of two of these previously disappea...

  10. Large and giant intracranial aneurysms: A radiologico-clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Lovrencic, M.; Jelicic, I.; Jakovac, I.; Kalousek, M.; Besenski, N.; Surdonja, P.

    1983-12-01

    The brain scans and cerebral angiograms of 13 patients with intracranial aneurysms larger than 15 mm. in diameter are analysed. The radiological findings obtained are compared with clinical symptoms and signs. Twelve patients had genuine aneurysms and one patient a posttraumatic false aneurysm. Post-contrast CT in transversal and coronal plane revealed the real size of the aneurysm in 7 cases of intraluminal thrombosis. Cerebral angiography demonstrated the presence of aneurysms, their anatomic relations and haemodynamic changes.

  11. Coiled-Coil–Mediated Dimerization Is Not Required for Myosin VI to Stabilize Actin during Spermatid Individualization in Drosophila melanogaster

    OpenAIRE

    Noguchi, Tatsuhiko; Frank, Deborah J.; Isaji, Mamiko; Miller, Kathryn G.

    2009-01-01

    Myosin VI is a pointed-end–directed actin motor that is thought to function as both a transporter of cargoes and an anchor, capable of binding cellular components to actin for long periods. Dimerization via a predicted coiled coil was hypothesized to regulate activity and motor properties. However, the importance of the coiled-coil sequence has not been tested in vivo. We used myosin VI's well-defined role in actin stabilization during Drosophila spermatid individualization to test the import...

  12. Adjustable Induction-Heating Coil

    Science.gov (United States)

    Ellis, Rod; Bartolotta, Paul

    1990-01-01

    Improved design for induction-heating work coil facilitates optimization of heating in different metal specimens. Three segments adjusted independently to obtain desired distribution of temperature. Reduces time needed to achieve required temperature profiles.

  13. Embedded optical microfiber coil resonator

    OpenAIRE

    Xu, Fei; Brambilla, Gilberto

    2007-01-01

    The embedding of an optical microfiber coil resonator in Teflon is demonstrated. Resonances in excess of 9dB and Q-factors greater than 6000 have been observed. The device is compact, robust and portable.

  14. Coil for LEAR extraction septum

    CERN Multimedia

    1982-01-01

    Which way does the current flow ? This intriguing object is the coil for the LEAR extraction septum. There were two septa, first a thin one, then this one, not so thin, somewhat on the borderline between septum and bending magnet.

  15. Movable coil type magnetic drives

    International Nuclear Information System (INIS)

    In movable coil type magnetic drives suitable to reactor control element drives, if it is intended to increase the retaining force thereof, there has been a problem that the size of the device is increased. Then in electromagnetic coils surrounding a plunger mounted to a driving shaft, auxiliary annular poles are disposed to each of inner ends of poles at both ends of the coils so as to cover almost of the surface on the side of the plunger. As a result, the magnetic bonding force between the electromagnetic coils and the plunger is enhanced, and the retaining force for the driving shaft can be increased by a small sized device without increasing current supplied to the electromagnetic coils and the number of the electromagnetic coils. The present invention is not limited to reactor control element drives, but it can be applied to various kinds of fields such as a driving device for moving materials in contactless manner, for example, in a case of removing drum cans containing radioactive materials or harmful materials. (N.H.)

  16. Dynamics of liquid rope coiling

    Science.gov (United States)

    Habibi, Mehdi; Maleki, Maniya; Golestanian, Ramin; Ribe, Neil M.; Bonn, Daniel

    2006-12-01

    We present a combined experimental and numerical investigation of the coiling of a liquid “rope” falling on a solid surface, focusing on three little-explored aspects of the phenomenon: The time dependence of “inertio-gravitational” coiling, the systematic dependence of the radii of the coil and the rope on the experimental parameters, and the “secondary buckling” of the columnar structure generated by high-frequency coiling. Inertio-gravitational coiling is characterized by oscillations between states with different frequencies, and we present experimental observations of four distinct branches of such states in the frequency-fall height space. The transitions between coexisting states have no characteristic period, may take place with or without a change in the sense of rotation, and usually (but not always) occur via an intermediate “figure of eight” state. We present extensive laboratory measurements of the radii of the coil and of the rope within it, and show that they agree well with the predictions of a “slender-rope” numerical model. Finally, we use dimensional analysis to reveal a systematic variation of the critical column height for secondary buckling as a function of (dimensionless) flow rate and surface tension parameters.

  17. Structural basis for cargo binding and autoinhibition of Bicaudal-D1 by a parallel coiled-coil with homotypic registry

    International Nuclear Information System (INIS)

    Bicaudal-D1 (BICD1) is an α-helical coiled-coil protein mediating the attachment of specific cargo to cytoplasmic dynein. It plays an essential role in minus end-directed intracellular transport along microtubules. The third C-terminal coiled-coil region of BICD1 (BICD1 CC3) has an important role in cargo sorting, including intracellular vesicles associating with the small GTPase Rab6 and the nuclear pore complex Ran binding protein 2 (RanBP2), and inhibiting the association with cytoplasmic dynein by binding to the first N-terminal coiled-coil region (CC1). The crystal structure of BICD1 CC3 revealed a parallel homodimeric coiled-coil with asymmetry and complementary knobs-into-holes interactions, differing from Drosophila BicD CC3. Furthermore, our binding study indicated that BICD1 CC3 possesses a binding surface for two distinct cargos, Rab6 and RanBP2, and that the CC1-binding site overlaps with the Rab6-binding site. These findings suggest a molecular basis for cargo recognition and autoinhibition of BICD proteins during dynein-dependent intracellular retrograde transport. - Highlights: • BICD1 CC3 is a parallel homodimeric coiled-coil with axial asymmetry. • The coiled-coil packing of BICD1 CC3 is adapted to the equivalent heptad position. • BICD1 CC3 has distinct binding sites for two classes of cargo, Rab6 and RanBP2. • The CC1-binding site of BICD1 CC3 overlaps with the Rab6-binding site

  18. Structural basis for cargo binding and autoinhibition of Bicaudal-D1 by a parallel coiled-coil with homotypic registry

    Energy Technology Data Exchange (ETDEWEB)

    Terawaki, Shin-ichi, E-mail: terawaki@gunma-u.ac.jp [Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515 (Japan); SPring-8 Center, RIKEN, 1-1-1 Koto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Yoshikane, Asuka [Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515 (Japan); SPring-8 Center, RIKEN, 1-1-1 Koto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Higuchi, Yoshiki [Department of Life Science, Graduate School of Life Science, University of Hyogo, 3-2-1 Koto, Kamigori-cho, Ako-gun, Hyogo 678-1297 (Japan); Department of Picobiology, Graduate School of Life Science, University of Hyogo, 3-2-1 Koto, Kamigori-cho, Ako-gun, Hyogo 678-1297 (Japan); SPring-8 Center, RIKEN, 1-1-1 Koto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Wakamatsu, Kaori [Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515 (Japan); SPring-8 Center, RIKEN, 1-1-1 Koto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan)

    2015-05-01

    Bicaudal-D1 (BICD1) is an α-helical coiled-coil protein mediating the attachment of specific cargo to cytoplasmic dynein. It plays an essential role in minus end-directed intracellular transport along microtubules. The third C-terminal coiled-coil region of BICD1 (BICD1 CC3) has an important role in cargo sorting, including intracellular vesicles associating with the small GTPase Rab6 and the nuclear pore complex Ran binding protein 2 (RanBP2), and inhibiting the association with cytoplasmic dynein by binding to the first N-terminal coiled-coil region (CC1). The crystal structure of BICD1 CC3 revealed a parallel homodimeric coiled-coil with asymmetry and complementary knobs-into-holes interactions, differing from Drosophila BicD CC3. Furthermore, our binding study indicated that BICD1 CC3 possesses a binding surface for two distinct cargos, Rab6 and RanBP2, and that the CC1-binding site overlaps with the Rab6-binding site. These findings suggest a molecular basis for cargo recognition and autoinhibition of BICD proteins during dynein-dependent intracellular retrograde transport. - Highlights: • BICD1 CC3 is a parallel homodimeric coiled-coil with axial asymmetry. • The coiled-coil packing of BICD1 CC3 is adapted to the equivalent heptad position. • BICD1 CC3 has distinct binding sites for two classes of cargo, Rab6 and RanBP2. • The CC1-binding site of BICD1 CC3 overlaps with the Rab6-binding site.

  19. Structure of Leishmania donovani coronin coiled coil domain reveals an antiparallel 4 helix bundle with inherent asymmetry.

    Science.gov (United States)

    Nayak, Ashok Ranjan; Karade, Sharanbasappa Shrimant; Srivastava, Vijay Kumar; Rana, Ajay Kumar; Gupta, C M; Sahasrabuddhe, Amogh A; Pratap, J Venkatesh

    2016-07-01

    Coiled coils are ubiquitous structural motifs that serve as a platform for protein-protein interactions and play a central role in myriad physiological processes. Though the formation of a coiled coil requires only the presence of suitably spaced hydrophobic residues, sequence specificities have also been associated with specific oligomeric states. RhXXhE is one such sequence motif, associated with parallel trimers, found in coronins and other proteins. Coronin, present in all eukaryotes, is an actin-associated protein involved in regulating actin turnover. Most eukaryotic coronins possess the RhXXhE trimerization motif. However, a unique feature of parasitic kinetoplastid coronin is that the positions of R and E are swapped within their coiled coil domain, but were still expected to form trimers. To understand the role of swapped motif in oligomeric specificity, we determined the X-ray crystal structure of Leishmania donovani coronin coiled coil domain (LdCoroCC) at 2.2Å, which surprisingly, reveals an anti-parallel tetramer assembly. Small angle X-ray scattering studies and chemical crosslinking confirm the tetramer in solution and is consistent with the oligomerization observed in the full length protein. Structural analyses reveal that LdCoroCC possesses an inherent asymmetry, in that one of the helices of the bundle is axially shifted with respect to the other three. The analysis also identifies steric reasons that cause this asymmetry. The bundle adapts an extended a-d-e core packing, the e residue being polar (with an exception) which results in a thermostable bundle with polar and apolar interfaces, unlike the existing a-d-e core antiparallel homotetramers with apolar core. Functional implications of the anti-parallel association in kinetoplastids are discussed. PMID:26940672

  20. HELMHOLTZ COILS FOR MEASURING MAGNETIC MOMENTS

    Directory of Open Access Journals (Sweden)

    P. N. Dobrodeyev

    2013-01-01

    Full Text Available The optimal configuration of the double Helmholtz coils for measuring of the magnetic dipole moments was defined. It was determined that measuring coils should have round shape and compensative coils – the square one. Analytically confirmed the feasibility of the proposed configuration of these coils as primary transmitters of magnetic dipole moments.

  1. The effect of endoleak on intra-aneurysmal pressure after EVE for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Objective: To investigate the intra-aneurysmal pressure curve in the presence of endoleak after endovascular exclusion (EVE) for abdominal aortic aneurysm (AAA). Methods: Infrarenal aortic aneurysms were created with bovine jugular vein segments or patches. Then they were underwent incomplete endovascular exclusion of the aneurysm and formation of endoleaks. The pressures of blood flow outside the graft into the sac were measured. Results: The intrasac pressure was higher than systemic pressure in the presence of endoleak. After sealing the endoleak, pressure decreased significantly, and the pressure cure showed approximately linear. Conclusion: The change of intra-aneurysmal pressure curve reflected the load on aneurysmal wall after EVE, and can also help to determine the endoleak existence

  2. Blood flow dynamic improvement with aneurysm repair detected by a patient-specific model of multiple aortic aneurysms.

    Science.gov (United States)

    Sughimoto, Koichi; Takahara, Yoshiharu; Mogi, Kenji; Yamazaki, Kenji; Tsubota, Ken'ichi; Liang, Fuyou; Liu, Hao

    2014-05-01

    Aortic aneurysms may cause the turbulence of blood flow and result in the energy loss of the blood flow, while grafting of the dilated aorta may ameliorate these hemodynamic disturbances, contributing to the alleviation of the energy efficiency of blood flow delivery. However, evaluating of the energy efficiency of blood flow in an aortic aneurysm has been technically difficult to estimate and not comprehensively understood yet. We devised a multiscale computational biomechanical model, introducing novel flow indices, to investigate a single male patient with multiple aortic aneurysms. Preoperative levels of wall shear stress and oscillatory shear index (OSI) were elevated but declined after staged grafting procedures: OSI decreased from 0.280 to 0.257 (first operation) and 0.221 (second operation). Graftings may strategically counter the loss of efficient blood delivery to improve hemodynamics of the aorta. The energy efficiency of blood flow also improved postoperatively. Novel indices of pulsatile pressure index (PPI) and pulsatile energy loss index (PELI) were evaluated to characterize and quantify energy loss of pulsatile blood flow. Mean PPI decreased from 0.445 to 0.423 (first operation) and 0.359 (second operation), respectively; while the preoperative PELI of 0.986 dropped to 0.820 and 0.831. Graftings contributed not only to ameliorate wall shear stress or oscillatory shear index but also to improve efficient blood flow. This patient-specific modeling will help in analyzing the mechanism of aortic aneurysm formation and may play an important role in quantifying the energy efficiency or loss in blood delivery. PMID:23852404

  3. Electronic database of arterial aneurysms

    Directory of Open Access Journals (Sweden)

    Fabiano Luiz Erzinger

    2014-12-01

    Full Text Available Background:The creation of an electronic database facilitates the storage of information, as well as streamlines the exchange of data, making easier the exchange of knowledge for future research.Objective:To construct an electronic database containing comprehensive and up-to-date clinical and surgical data on the most common arterial aneurysms, to help advance scientific research.Methods:The most important specialist textbooks and articles found in journals and on internet databases were reviewed in order to define the basic structure of the protocol. Data were computerized using the SINPE© system for integrated electronic protocols and tested in a pilot study.Results:The data entered onto the system was first used to create a Master protocol, organized into a structure of top-level directories covering a large proportion of the content on vascular diseases as follows: patient history; physical examination; supplementary tests and examinations; diagnosis; treatment; and clinical course. By selecting items from the Master protocol, Specific protocols were then created for the 22 arterial sites most often involved by aneurysms. The program provides a method for collection of data on patients including clinical characteristics (patient history and physical examination, supplementary tests and examinations, treatments received and follow-up care after treatment. Any information of interest on these patients that is contained in the protocol can then be used to query the database and select data for studies.Conclusions:It proved possible to construct a database of clinical and surgical data on the arterial aneurysms of greatest interest and, by adapting the data to specific software, the database was integrated into the SINPE© system, thereby providing a standardized method for collection of data on these patients and tools for retrieving this information in an organized manner for use in scientific studies.

  4. Complications of endovascular treatment of cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Orrù, Emanuele, E-mail: surgeon.ema@gmail.com [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Roccatagliata, Luca, E-mail: lroccatagliata@neurologia.unige.it [Neuroradiology Department, IRCCS San Martino University Hospital and IST, Largo Rosanna Benzi 10, Genoa 16132 (Italy); Department of Health Sciences (DISSAL), University of Genoa (Italy); Cester, Giacomo, E-mail: giacomo.cester@sanita.padova.it [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Causin, Francesco, E-mail: francesco.causin@sanita.padova.it [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Castellan, Lucio, E-mail: lucio.castellan@hsanmartino.it [Neuroradiology Department, IRCCS San Martino University Hospital and IST, Largo Rosanna Benzi 10, Genoa 16132 (Italy)

    2013-10-01

    The number of neuroendovascular treatments of both ruptured and unruptured aneurysms has increased substantially in the last two decades. Complications of endovascular treatments of cerebral aneurysms are rare but can potentially lead to acute worsening of the neurological status, to new neurological deficits or death. Some of the possible complications, such as vascular access site complications or systemic side effects associated with contrast medium (e.g. contrast medium allergy, contrast induced nephropathy) can also be encountered in diagnostic angiography. The most common complications of endovascular treatment of cerebral aneurysms are related to acute thromboembolic events and perforation of the aneurysm. Overall, the reported rate of thromboembolic complications ranges between 4.7% and 12.5% while the rate of intraprocedural rupture of cerebral aneurysms is about 0.7% in patients with unruptured aneurysms and about 4.1% in patients with previously ruptured aneurysms. Thromboembolic and hemorrhagic complications may occur during different phases of endovascular procedures and are related to different technical, clinical and anatomic reasons. A thorough knowledge of the different aspects of these complications can reduce the risk of their occurrence and minimize their clinical sequelae. A deep understanding of complications and of their management is thus part of the best standard of care.

  5. Screening for Abdominal Aortic Aneurysm

    OpenAIRE

    Linné, Anneli

    2014-01-01

    Abdominal Aortic Aneurysm (AAA) is a common disease with a prevalence of 1.5-2.0% in 65-year old men in Sweden. The risk of having AAA is increased with smoking, high age, family history of AAA and cardiovascular disease. Women have a lower prevalence (0.5%) and develop AAA later in life. An AAA seldom gives any symptom prior to rupture. Untreated rupture is associated with 100% mortality, while surgically treated rupture is associated with 25-70% mortality. Prophylactic sur...

  6. PATIENT-SPECIFIC BLOOD DYNAMIC SIMULATIONS IN ASSESSING ENDOVASCULAR OCCLUSION OF INTRACRANIAL ANEURYSMS

    Institute of Scientific and Technical Information of China (English)

    CHEN Jia-liang; WANG Sheng-zhang; DING Guang-hong; YANG Xin-jian; LI Hai-yun

    2009-01-01

    According to recent studies, there are various potential predictors for surgical outcome for cerebral aneurysms. An accurate surgical outcome assessment would help make better-informed decisions and avoid the risk of rebleeding. It is well known that hemodynamic factors play an important role in the pathogenesis and treatment of intracranial aneurysms. In this article, a computational fluid dynamic analysis is applied to one patient-specific model of the cerebral aneurysm located at the tip of basilar artery, by which the differences of hemodynamic parameters before and after endovascular treatment may be evaluated. Based on the model, we show that the flow behavior near the neck of the aneurysm sees great differences after endovascular treatment as compared with that before treatment, which also affects the wall shear stress and the displacement distribution. In addition, our whole simulation process is based on a series of CFD commercial software packages, which are easily available for doctors to implement such a method in their daily practice. These results would be used to assess the outcome of endovascular treatment for the aneurysm occlusion.

  7. Nuclear medical diagnostic with ventricular aneurysm

    International Nuclear Information System (INIS)

    In the diagnostic of ventricular aneurysms myocardial scintigraphy and above all radionuclide ventriculography (RNV) have special importance. Because of the non-invasive method and the as a result safe and easy use even with stress studies, RNV can provide a very valuable aid with aneurysm patients in early diagnosis, evaluation of the operability and as well as in the prognosis. It must be noted, however, that the differentiation of multivascular diseases and sometimes ventricular aneurysms can be difficult and the inclusion of an angiocardiograph as a radiological invasive examination procedure seems fitting. (orig./MG)

  8. Abdominal aortic aneurysm demonstrated on renal scintigraphy.

    Science.gov (United States)

    Phisitkul, Sorot; Brian, Susan; Rakvit, Ariwan; Jenkins, Leigh A; Bohannon, W Todd; Harris, Jennifer; Tsikouris, James; Silva, Michael B; Meyerrose, Gary E

    2003-08-01

    A 74-year-old hypertensive woman presented with abdominal discomfort and a pulsatile abdominal mass. Anterior abdominal angiography during cardiac blood pool, and renal scintigraphic imaging demonstrated a large abdominal aortic aneurysm. 1, 2 Before endovascular repair with an aortoiliac endograft, the abdominal aneurysm measured 7.5 x 7.0 cm on abdominal computed tomography. This study demonstrates that a suspected abdominal aortic aneurysm can be confirmed using the addition of anterior abdominal imaging with normal posterior imaging at the time of renal scintigraphy. PMID:12897671

  9. Bicaudal-D uses a parallel, homodimeric coiled coil with heterotypic registry to coordinate recruitment of cargos to dynein.

    Science.gov (United States)

    Liu, Yang; Salter, Hannah K; Holding, Andrew N; Johnson, Christopher M; Stephens, Elaine; Lukavsky, Peter J; Walshaw, John; Bullock, Simon L

    2013-06-01

    Cytoplasmic dynein is the major minus end-directed microtubule motor in eukaryotes. However, there is little structural insight into how different cargos are recognized and linked to the motor complex. Here we describe the 2.2 Å resolution crystal structure of a cargo-binding region of the dynein adaptor Bicaudal-D (BicD), which reveals a parallel coiled-coil homodimer. We identify a shared binding site for two cargo-associated proteins-Rab6 and the RNA-binding protein Egalitarian (Egl)-within a region of the BicD structure with classical, homotypic core packing. Structure-based mutagenesis in Drosophila provides evidence that occupancy of this site drives association of BicD with dynein, thereby coupling motor recruitment to cargo availability. The structure also contains a region in which, remarkably, the same residues in the polypeptide sequence have different heptad registry in each chain. In vitro and in vivo analysis of a classical Drosophila dominant mutation reveals that this heterotypic region regulates the recruitment of dynein to BicD. Our results support a model in which the heterotypic segment is part of a molecular switch that promotes release of BicD autoinhibition following cargo binding to the neighboring, homotypic coiled-coil region. Overall, our data reveal a pivotal role of a highly asymmetric coiled-coil domain in coordinating the assembly of cargo-motor complexes. PMID:23723415

  10. Endovascular Treatment of Isolated Bilateral Internal Ili- ac Artery Aneurysms with a Branched Endograft: A Case Report

    Directory of Open Access Journals (Sweden)

    SeyedEbrahim Kassaian

    2015-10-01

    Full Text Available Isolated bilateral internal iliac artery (IIA aneurysm is a rare and potentially lethal disease. Endovascular repair of this disorder is a matter of debate. A symptomatic 68-year-old male presented with severe pelvic pains. Computed tomography revealed a leaking 46-mm aneurysm in the right IIA, a 27-mm aneurysm in the left IIA, and ectatic changes at a diameter of 31 mm in the right common iliac artery (CIA. Due to lower rates of morbidity and mortality, an endovascular approach was chosen instead of open surgical repair. However, due to anatomical constraints, an endograft had to be implanted in a healthy aorta in order to support an iliac branch endograft in the left CIA. Subsequently, following coil embolization of the left IIA, an iliac stent graft was extended to the right external iliac artery (EIA. Two-year follow-up CT imaging showed complete exclusion of all the aneurysms and patency of the pelvic visceral arteries. The patient is currently asymptomatic.Endovascular repair of bilateral isolated IIAs can be a feasible treatment option. However, due to limited availability of sizes in iliac branch devices currently on the market, a main body device is sometimes required to be deployed in a healthy aorta for additional endograft support.

  11. Dimerization of the DYT6 dystonia protein, THAP1, requires residues within the coiled-coil domain.

    Science.gov (United States)

    Sengel, Cem; Gavarini, Sophie; Sharma, Nutan; Ozelius, Laurie J; Bragg, D Cristopher

    2011-09-01

    Thanatos-associated [THAP] domain-containing apoptosis-associated protein 1 (THAP1) is a DNA-binding protein that has been recently associated with DYT6 dystonia, a hereditary movement disorder involving sustained, involuntary muscle contractions. A large number of dystonia-related mutations have been identified in THAP1 in diverse patient populations worldwide. Previous reports have suggested that THAP1 oligomerizes with itself via a C-terminal coiled-coil domain, raising the possibility that DYT6 mutations in this region might affect this interaction. In this study, we examined the ability of wild-type THAP1 to bind itself and the effects on this interaction of the following disease mutations: C54Y, F81L, ΔF132, T142A, I149T, Q154fs180X, and A166T. The results confirmed that wild-type THAP1 associated with itself and most of the DYT6 mutants tested, except for the Q154fs180X variant, which loses most of the coiled-coil domain because of a frameshift at position 154. However, deletion of C-terminal residues after position 166 produced a truncated variant of THAP1 that was able to bind the wild-type protein. The interaction of THAP1 with itself therefore required residues within a 13-amino acid region (aa 154-166) of the coiled-coil domain. Further inspection of this sequence revealed elements highly consistent with previous descriptions of leucine zippers, which serve as dimerization domains in other transcription factor families. Based on this similarity, a structural model was generated to predict how hydrophobic residues in this region may mediate dimerization. These observations offer additional insight into the role of the coiled-coil domain in THAP1, which may facilitate future analyses of DYT6 mutations in this region. PMID:21752024

  12. Endovascular therapy of abdominal aortic aneurysm: results of a mid-term follow-up

    International Nuclear Information System (INIS)

    Prospective study to evaluate clinical results and complications of endovascular abdominal aortic aneurysm treatment in a mid-term follow-up. Materials and methods: A total of 122 patients (9 females, 113 males, average age 70.0±7,9 years) with abdominal aortic aneurysms were treated with stent grafts (53 Vanguard or Stentor endografts, 69 Talent endografts). Group I consisted of 40 patients who had all aortic tributaries of the aneurysm sac occluded prior to endovalscular grafting, either spontaneously by parietal thrombosis or by selective coil embolization of the respective ostia preserving collateral circulation distal to the vessel occlusion. Group II consisted of 82 patients and included all cases without or with incomplete coil embolization with at least one patent vessel. Stent grafting was performed in general anesthesia in the first 21 patients, followed by peridural anesthesia in 15 cases, and local anesthesia with conscious sedation in 86 cases. The results were evaluated with Spiral-CT, MRI and radiographs of the endovascular graft, with follow-up examinations obtained at 3, 6, 12 months, and every year - Implantation was successfully completed in all cases without primary conversion surgery, laparotomy or any significant complication. Mean follow-up was 29±21 months (maximum 82 months). The 30-day mortality was 0,8% due to a myocardial infarction 3 days after discharge from the hospital. A total of 47 re-interventions were performed in 29 patients (23.8%), with 35 re-interventions in 18 cases with Vanguard or Stentor endografts and 12 re-interventions in 11 patients with Talent endografts. 23 percutaneous re-interventions included distal graft extension (n=11), Wallstent for kinking and limb stenosis (n=3), and secondary coil embolization of collateral vessels (n=9). 24 surgical re-interventions included proximal graft extension (n=6), new endovascular grafts (n=3), surgical clipping of lumbar and mesenteric artery branches for type-II endoleaks

  13. Targeted polymer therapeutics with a coiled coil motif

    Czech Academy of Sciences Publication Activity Database

    Pechar, Michal; Pola, Robert; Ulbrich, Karel; Bednárová, Lucie; Maloň, Petr; Sieglová, Irena; Král, Vlastimil; Fábry, Milan; Kabešová, Martina; Kovář, Marek

    Heraklion : University of Crete, 2012. s. 28. [BIONANOTOX 2012 - "Biomaterials and Bionanomaterials: Recent Problems and Safety Issues", Russian-Hellenic Symposium with International Participation and Young Scientists School /3./, Advanced Research Workshop on Nanotechnologies & Bioanalytical Advances for Improved Public Security and Enviromental Safety and Health. 06.05.2012-13.05.2012, Heraklion] R&D Projects: GA AV ČR IAAX00500803 Institutional research plan: CEZ:AV0Z40500505; CEZ:AV0Z40550506; CEZ:AV0Z50520514; CEZ:AV0Z50200510 Institutional support: RVO:61389013 ; RVO:61388963 ; RVO:68378050 ; RVO:61388971 Keywords : drug carriers * coiled coil * HPMA Subject RIV: CD - Macromolecular Chemistry

  14. Bilateral giant femoropopliteal artery aneurysms: a case report

    Directory of Open Access Journals (Sweden)

    Perdikides Theodossios P

    2008-04-01

    Full Text Available Abstract Introduction Popliteal artery aneurysms are the most common peripheral arterial aneurysms, and are frequently bilateral. Acute limb ischemia, rupture and compression phenomena can complicate these aneurysms when the diameter exceeds 2 cm. Case Presentation We report an 82-year-old male patient with two giant femoropopliteal aneurysms, 10.5 and 8.5 cm diameters, managed in our institution. Both aneurysms were resected and a polytetrafluoroethylene (PTFE femoropopliteal interposition graft was placed successfully. Management and literature review are discussed. Conclusion We believe this is the first report in the medical literature of bilateral giant femoropopliteal aneurysms.

  15. Infectious or Noninfectious? Ruptured, Thrombosed Inflammatory Aortic Aneurysm with Spondylolysis

    Energy Technology Data Exchange (ETDEWEB)

    Stefanczyk, Ludomir; Elgalal, Marcin, E-mail: telgalal@yahoo.co.uk [Medical University of Lodz, Department of Radiology and Diagnostic Imaging (Poland); Papiewski, Andrzej [Medical University of Lodz, Department of Gastroenterological Surgery (Poland); Szubert, Wojciech [Medical University of Lodz, Department of Radiology and Diagnostic Imaging (Poland); Szopinski, Piotr [Institute of Hematology and Transfusion Medicine, Clinic of Vascular Surgery (Poland)

    2013-06-15

    Osteolysis of vertebrae due to inflammatory aortic aneurysm is rarely observed. However, it is estimated that up to 10 % of infectious aneurysms coexist with bone tissue destruction, most commonly the vertebrae. Inflammatory aneurysms with no identified infection factor, along with infiltration of adjacent muscle and in particular extensive destruction of bone tissue have rarely been described in the literature. A case of inflammatory aneurysm with posterior wall rupture and inflammatory infiltration of the iliopsoas muscle and spine, together with extensive vertebral body destruction, is presented. The aneurysm was successfully treated with endovascular aneurysm repair EVAR.

  16. Deformation of Linked Polymer Coils

    Institute of Scientific and Technical Information of China (English)

    董朝霞; 李明远; 吴肇亮; 林梅钦

    2003-01-01

    Linked polymer solution (LPS) is defined as the solution of linked polymer coils (LPCs) dispersed in water, composed of low concentration partially hydrolyzed polyacrylamide (HPAM) and aluminum citrate (crosslinker). In the work, the conformational changes of LPCs under different conditions were investigated by the methods of membrane filtering under low pressure, dynamic light scattering and core flooding experiments. The results showed that in some conditions the LPCs could be compressed mechanically to 1/158.5 of their original volume because of relatively lower HPAM cross-linking. The hydration property of LPCs was similar to that of normal polymer coils. The deformation of LPCs was more restricted than that of ordinary polymer coils under the flow shear stress or the shift of hydration equilibrium caused in the variation of the electrolyte concentration which is responsible for the effective plugging in the throats of porous media when LPCs are used for deep diverting.

  17. Long-term monitoring of hydraulic characteristics of LHD poloidal coils

    International Nuclear Information System (INIS)

    We present a fourteen-year data summary of the hydraulic characteristics of the large helical device (LHD) poloidal coils. The superconductors of the poloidal coils are cable-in-conduit conductors (CICC) cooled by circulated supercritical helium. The long-term operation of the LHD demonstrates that the initial hydraulic characteristics can be maintained without flow obstruction. Fine mesh filters installed at the inlet trapped impurities during cool-down of the coils, confirmed by monitoring the pressure drop of the filters. The filters have an important role in removing particles of impurities in the helium and maintaining the hydraulic characteristics of the coils. (author)

  18. Venous Aneurysm Complicating Dialytic Arteriovenous Fistula

    OpenAIRE

    Arjun K.Nambiar; Anand, K. T.; Jayakrishnan, A. G.

    2012-01-01

    A case of venous aneurysm complicating arteriovenous fistula created for chronic haemodialysis is presented. The patient underwent successful ligation and excision of the fistula and creation of a fistula on the opposite limb.

  19. Asthma May Raise Risk for Abdominal Aneurysm

    Science.gov (United States)

    ... nlm.nih.gov/medlineplus/news/fullstory_157202.html Asthma May Raise Risk for Abdominal Aneurysm Airway disease ... People 50 and older who have had recent asthma activity appear to be at an increased risk ...

  20. Tubercular mycotic aortic aneurysm: A case report

    Directory of Open Access Journals (Sweden)

    Satish Kumar

    2016-01-01

    Full Text Available Tubercular aneurysms of larger vessels, particularly the aorta is very rare. The first case of tubercular involvement of the aorta in the form of aortitis was reported in 1882 by Weigert and the first case of tubercular mycotic aneurysm of the aorta was reported in 1895. The preoperative diagnosis of tubercular aortic aneurysm is difficult. Even at surgery, determining the tubercular nature of the lesion is problematic. The gross appearance may not be distinctive, and acid-fast stains are unlikely to be performed. We report the case of a young female patient who was started on antitubercular treatment for pleural effusion and was found to have aortic aneurysm, which later on proved to be tubercular in origin.

  1. Dissecting aortic aneurysm in maintenance hemodialysis patients

    Directory of Open Access Journals (Sweden)

    Ounissi M

    2009-01-01

    Full Text Available The dissecting aortic aneurysm (DAA is a rare pathology that may result in fatal outcome. We report follow up of three cases of DAA patients undergoing maintenance hemo-dialysis who were managed conservatively.

  2. Aneurysm of the vein of Galen

    International Nuclear Information System (INIS)

    We report a case of a vein of Galen aneurysm in a neonate in which MR imaging provided essentially all pertinent diagnostic information prior to surgery. MR findings correlated well with selective cerebral angiography. (orig./MG)

  3. Endovascular repair of aortic aneurysm: Preliminary results

    Directory of Open Access Journals (Sweden)

    Davidović Lazar

    2009-01-01

    Full Text Available Introduction. Endovascular aneurysm repair (EVAR has been introduced into clinical practice at the beginning of the 90's of the last century. Because of economic, political and social problems during the last 25 years, the introduction of this procedure in Serbia was not possible. Objective. The aim of this study was to present preliminary experiences and results of the Clinic for Vascular Surgery of the Serbian Clinical Centre in Belgrade in endovascular treatment of thoracic and abdominal aortic aneurysms. Methods. The procedure was performed in 33 patients (3 female and 30 male, aged from 42 to 83 years. Ten patients had a descending thoracic aorta aneurysm (three atherosclerotic, four traumatic - three chronic and one acute as a part of polytrauma, one dissected, two penetrated atherosclerotic ulcers, while 23 patients had the abdominal aortic aneurysm, one ruptured and two isolated iliac artery aneurysms. The indications for EVAR were isthmic aneurismal localisation, aged over 80 years and associated comorbidity (cardiac, pulmonary and cerebrovasular diseases, previous thoracotomy or multiple laparotomies associated with abdominal infection, idiopatic thrombocitopaenia. All of these patients had three or more risk factors. The diagnosis was established using duplex ultrasonography, angiography and MSCT. In the case of thoracic aneurysm, a Medtronic-Valiant® endovascular stent graft was implanted, while for the abdominal aortic aneurysm Medtronic-Talent® endovascular stent grafts with delivery systems were used. In three patients, following EVAR a surgical repair of the femoral artery aneurysm was performed, and in another three patients femoro-femoral cross over bypass followed implantation of aortouniiliac stent graft. Results. During procedure and follow-up period (mean 1.6 years, there were: one death, one conversion, one endoleak type 1, six patients with endoleak type 2 that disappeared during the follow-up period, one early graft

  4. Cooling device of superconducting coils

    International Nuclear Information System (INIS)

    This device is rotating around an horizontal axis. The superconducting coils are contained in a cryogenic enclosure feeded in liquid helium forced circulation. They are related to an electric generator by electric mains each of them comprising a gas exchanger, and an exchanger-evaporator set between the cryogenic device and those exchangers. The exchanger-evaporator is aimed at dissipating the heat arriving by conductors connected to the superconducting coils. According to the invention, the invention includes an annular canalization with horizontal axis in which the connection conductors bathe in liquid helium

  5. Image-based investigation of hemodynamics and rupture of cerebral aneurysms of a single morphological type: terminal aneurysms

    Science.gov (United States)

    Castro, Marcelo; Putman, Christopher; Radaelli, Alessandro; Frangi, Alejandro; Cebral, Juan

    2008-03-01

    In this study, the relationship between hemodynamics patterns and aneurysmal rupture was investigated in cerebral aneurysms of a single morphological type (terminal aneurysms) regardless of their location. Hemodynamics information (intra-aneurysmal velocity and pressure fields and wall shear stress distributions) was derived from image-based computational fluid dynamics models with realistic patient specific anatomies. A total of 41 patient-specific models constructed from 3D rotational angiography images were analyzed. The results suggest that high wall shear stress may be associated with aneurysm rupture and that in turn different flow splitting patterns from the parent artery to the daughter branches and the aneurysm produce different levels of wall shear stress.

  6. Matrix Metalloproteinases in Cerebral Vasospasm following Aneurysmal Subarachnoid Hemorrhage

    Directory of Open Access Journals (Sweden)

    Vivek Mehta

    2013-01-01

    Full Text Available Delayed cerebral vasospasm is a significant cause of morbidity and mortality following aneurysmal subarachnoid hemorrhage (SAH. While the cellular mechanisms underlying vasospasm remain unclear, it is believed that inflammation may play a critical role in vasospasm. Matrix metalloproteinasees (MMPs are a family of extracellular and membrane-bound proteases capable of degrading the blood-rain barrier (BBB. As such, MMP upregulation following SAH may result in a proinflammatory extravascular environment capable of inciting delayed cerebral vasospasm. This paper presents an overview of MMPs and describes existing data pertinent to delayed cerebral vasospasm.

  7. Splenic artery aneurysm rupture in pregnancy

    International Nuclear Information System (INIS)

    Rupture of a splenic artery aneurysm, commonly associated with pregnancy is a rare and catastrophic event. We report here a case of a patient in her second pregnancy who presented with a short history of left hypochondriac and epigastric pain, followed by collapse at 32 weeks gestation. Sudden fetal distress lead to emergency caesarean delivery when splenic artery aneurysm rupture was diagnosed. With timely involvement of multidisciplinary personnel both mother and baby survived and had an uneventful recovery. (author)

  8. Multiple Intracranial Aneurysms in HIV Infection.

    Science.gov (United States)

    Dhawan, Sumeet R; Gupta, Anju; Gupta, Vivek; Singhi, Pratibha D

    2016-08-01

    Neurological findings in HIV are common and include cognitive impairment, microcephaly, nonspecific white matter lesions and seizures. Cerebral vasculopathy and stroke are uncommon and may be due to primary HIV vasculopathy or opportunistic infections such as tuberculosis and cryptococcal meningitis. The authors describe a 7-y-old boy who presented with severe headache and was detected to have aneurysmal bleed due to intracranial aneurysm. PMID:27072660

  9. Predictive risk factors for multiple intracranial aneurysms rupture

    International Nuclear Information System (INIS)

    Objective: To analyze the risk factors inducing the rupture of multiple intracranial aneurysms. Methods: Between July 2007 and July 2011, a total of 134 patients with 294 aneurysms were admitted to the hospital. Of the 294 aneurysms, 50 were ruptured and 244 were unruptured. Every patient had two or more aneurysms. Univariate and multivariate logistic regression analysis methods were used to analyze the risk factors, including age, gender, site and size, for multiple intracranial aneurysms. Results: The 134 patients were divided into three groups according to patient's age, including <4.5 group, (45-6.5) group and > 65 group. The rupture incidence of aneurysm in the (4.5-65) group was highest in the three groups. The difference was significant (P=0.001). Of 35 patients with anterior communicating arterial aneurysms, 13 (37.1%) were ruptured, accounting for 26% of all ruptured aneurysms, and the rupture rate of anterior communicating arterial aneurysms was significantly higher than that of the aneurysms located at other sites (P= 0.001). Of all 294 aneurysms, 88.1% were <5 mm, 58.2% were <3 mm. Of the ruptured aneurysms, 680-/o were <5 mm. Conclusion: This study indicates that the rupture of multiple intracranial aneurysm is closely related to the patient's age, the size and location of aneurysm. Therefore, patient's age, the size and location of aneurysm should be taken into consideration when to make the therapeutic plan. In multiple intracranial aneurysms, the anterior communicating arterial aneurysm is most prone to bleeding. (authors)

  10. Fronto-temporo-orbitozygomatic craniotomy and "half-and-half" approach for basilar apex aneurysms

    Directory of Open Access Journals (Sweden)

    Behari Sanjay

    2009-01-01

    Full Text Available Background: Basilar apex aneurysms (BAA are located in interpeduncular cistern surrounded by eloquent neurovascular structures. Surgical access is difficult due to narrow surgical corridors and requires traversing through a depth of 6-8 cm of subarachnoid space. Aim: Surgical management of BAAs clipped using frontotemporal craniotomy, orbitozygomatic osteotomy with combined subtemporal and transylvian (half and half approach is discussed. Setting and Design: Tertiary care referral institute; prospective study. Materials and Methods: Five patients with BAA rupture causing subarachnoid hemorrhage presented in modified Hunt and Hess (Hand H grades II (n=1, III (n=1 and IV (n=3, respectively. In 4 patients, the aneurysms were 0.8-1.2 cm in diameter, situated 7 mm-1 cm above dorsum sellae. Two of them had posteriorly projecting aneurysms. One patient had a giant, high BAA with a left parietooccipital arteriovenous malformation. Vasospasm of posterior cerebral/proximal basilar artery was seen in 2 patients. In one patient, internal carotid artery was mobilized by intradural anterior clinoid drilling with carotid collar division. Triple-H therapy was administered following surgery. Results: There was no intraoperative rupture or temporary clipping. Follow up angiography showed complete aneurysmal obliteration with preservation of posterior cerebral and superior cerebellar arteries. Follow up (mean: 8.7 ± 3.5 months H and H grades were II (n=2 and III (n=3, respectively. The morbidity include caudate and thalamic region infarct, transient III rd nerve palsy and cerebrospinal fluid otorrhoea (n=1, respectively. Conclusions: This simple approach provides a wide surgical corridor from 5 mm below to greater than 1 cm above dorsum sellae with adequate proximal control of basilar artery. It is an option to endovascular embolization especially with large and giant, or wide-necked BAA, vertebrobasilar tortuosity, coil compaction or postcoiling re-rupture and

  11. The fate of cranial neuropathy after flow diversion for carotid aneurysms.

    Science.gov (United States)

    Brown, Benjamin L; Lopes, Demetrius; Miller, David A; Tawk, Rabih G; Brasiliense, Leonardo B C; Ringer, Andrew; Sauvageau, Eric; Powers, Ciarán J; Arthur, Adam; Hoit, Daniel; Snyder, Kenneth; Siddiqui, Adnan; Levy, Elad; Hopkins, L Nelson; Cuellar, Hugo; Rodriguez-Mercado, Rafael; Veznedaroglu, Erol; Binning, Mandy; Mocco, J; Aguilar-Salinas, Pedro; Boulos, Alan; Yamamoto, Junichi; Hanel, Ricardo A

    2016-04-01

    % (3/10) of those with complete deficits. CONCLUSIONS Cranial neuropathy caused by cerebral aneurysm responds similarly when the aneurysm is treated with the PED compared with open surgery and coil embolization. Lower morbidity and higher occlusion rates obtained with the PED may suggest it as treatment of choice for some of these lesions. Time to treatment is an important consideration regardless of treatment modality. PMID:26473786

  12. Lipolysis of emulsion models of triglyceride-rich lipoproteins is altered in male patients with abdominal aorta aneurysm

    Directory of Open Access Journals (Sweden)

    J.J. Hosni

    2007-03-01

    Full Text Available Disorders of the lipid metabolism may play a role in the genesis of abdominal aorta aneurysm. The present study examined the intravascular catabolism of chylomicrons, the lipoproteins that carry the dietary lipids absorbed by the intestine in the circulation in patients with abdominal aorta aneurysm. Thirteen male patients (72 ± 5 years with abdominal aorta aneurysm with normal plasma lipid profile and 13 healthy male control subjects (73 ± 5 years participated in the study. The method of chylomicron-like emulsions was used to evaluate this metabolism. The emulsion labeled with 14C-cholesteryl oleate and ³H-triolein was injected intravenously in both groups. Blood samples were taken at regular intervals over 60 min to determine the decay curves. The fractional clearance rate (FCR of the radioactive labels was calculated by compartmental analysis. The FCR of the emulsion with ³H-triolein was smaller in the aortic aneurysm patients than in controls (0.025 ± 0.017 vs 0.039 ± 0.019 min-1; P < 0.05, but the FCR of14C-cholesteryl oleate of both groups did not differ. In conclusion, as indicated by the triglyceride FCR, chylomicron lipolysis is diminished in male patients with aortic aneurysm, whereas the remnant removal which is traced by the cholesteryl oleate FCR is not altered. The results suggest that defects in the chylomicron metabolism may represent a risk factor for development of abdominal aortic aneurysm.

  13. Computed tomography of the aortic aneurysm

    International Nuclear Information System (INIS)

    The diagnostic usefulness of CT was studied in 31 cases in total of thoracic and abdominal aneurysm. CT was useful for not only visualizing the transverse plane and wall of an aneurysm but also ascertaining the status of destruction of vertebra due to aneurysm. CT was considered to be of value, particularly for diagnosis of dissecting aneurysm. Of 8 cases of dissecting aneurysm, it in fact brought about a correct diagnosis in 6 cases (75%). The tomographic findings in these cases were characterized by formation of images of the exfoliated intima and dissection cavity, abnormality in the site of intimal calcification, and delay in opacification of the dissection cavity. The use of a bolus injection of contrast medium is recommended in the CT of thoracic or abdominal aneurysm. Since CT can be performed non-invasively, it is suitable for follow-up of the clinical course of dissection cavity. The CT value of thrombi varies among individual cases, which raises a possibility that the CT value may reflect the time-course change in their properties after thrombogenesis. (author)

  14. Symptomatic calcified splenic artery aneurysm: Case report

    Directory of Open Access Journals (Sweden)

    Čolović Radoje

    2010-01-01

    Full Text Available Introduction. Although the third most common aneurysm within the abdomen, after aneurysms of the aorta and iliac arteries, splenic artery aneurysms are rare, but not exceptionally. Owing to new imaging techniques, they have been discovered with increasing frequency. Case Outline. Authors present a 47-year-old woman, multipara, who presented with left upper abdominal pain in whom X-ray showed a calcified ring in the area of distal pancreas. Selective angiography confirmed a splenic artery aneurysm of its proximal part. During an open surgery the aneurysm was excised (aneurismectomy without immediate, early or late complications. The patient became symptom-free. Conclusion. In patients, particularly women, the multiparas who present with epigastric or left upper abdominal pain of unknown aetiology, splenic artery aneurysm has to be taken into account. Further diagnostic procedures such as plain X-ray and selective angiography in suspected cases should be performed. Surgery or other treatment modalities are to be seriously considered in all patients, particularly in those with increased risk of rupture.

  15. Intracranial aneurysms in an African country

    Directory of Open Access Journals (Sweden)

    Ogeng'o Julius

    2009-12-01

    Full Text Available Background : Characteristics of intracranial aneurysms display ethnic variations. Data on this disease from the African continent is scarce and often conflicting. Aim : To describe site, age and gender distribution of intracranial aneurysms among Kenyans. Study Design and Setting : Retrospective study at Kenyatta National Hospital, Kenya. Materials and Methods: All records of black African patients with a diagnosis of intracranial aneurysms seen at Kenyatta National Hospital, the largest referral hospital in the Eastern and Central African region, over the period from January 1998 to December 2007 were examined for site, age and gender distribution. The data gathered were coded, analyzed with SPSS 11.50. Results : Fifty-six cases of intracranial aneurysms were analyzed. The posterior communicating artery was the most affected (35.7%, followed by the anterior communicating artery (26.8%, while the posterior cerebral artery was the least affected (2%. Multiple aneurysms were present in 2%. The mean age at presentation was 50.9 years (range 21-80 years and the gender distribution was equal. Conclusions : Intracranial aneurysms among Kenyans occur most commonly on the posterior communicating artery, in young individuals, and without gender bias. The distribution differs from that described in the literature and this requires search for risk factors.

  16. Bronchial Artery Aneurysm Embolization with NBCA

    International Nuclear Information System (INIS)

    We present a case of asymptomatic bronchial artery aneurysm that formed a fistula with part of the pulmonary artery (there was no definite fistula with the pulmonary vein). We were able to catheterize the feeding vessel but could not reach the aneurysm. We therefore injected a mixture of N-butyl-2-cyanoacrylate (NBCA; Histoacryl, B. Braun, Melsungen, Germany) and iodized oil (Lipiodol; Guerbet, Aulnay-sous-Bois, France) from the feeding vessel. The fistula, aneurysm, and feeding vessel were almost totally occluded. After embolization, the patient coughed a little; there were no other definite side effects or complications. One and 3 months later, on chest CT, the aneurysm was almost completely occupied with hyperattenuating NBCA-Lipiodol embolization. NBCA is a liquid embolization material whose time to coagulation after injection can be controlled by diluting it with Lipiodol. It is therefore possible to embolize an aneurysm, feeding vessels, and efferent vessels (in our case, it was a fistula) by using an NBCA-Lipiodol mixture of an appropriate concentration, regardless of whether the catheter can reach the aneurysm or not

  17. Potential value of aneurysm sac volume measurements in addition to diameter measurements after endovascular aneurysm repair.

    NARCIS (Netherlands)

    Keulen, J.W. van; Prehn, J. van; Prokop, M.; Moll, F.L.; Herwaarden, J.A. van

    2009-01-01

    PURPOSE:To investigate the value of aneurysm sac volume measurement in addition to diameter measurements based on computed tomographic angiography (CTA) after endovascular aneurysm repair (EVAR). METHODS:Interrogation of a vascular database identified 56 patients (51 men; median age 77 years, range

  18. Large Coil Program magnetic system design study

    International Nuclear Information System (INIS)

    The primary objective of the Large Coil Program (LCP) is to demonstrate the reliable operation of large superconducting coils to provide a basis for the design principles, materials, and fabrication techniques proposed for the toroidal magnets for the THE NEXT STEP (TNS) and other future tokamak devices. This paper documents a design study of the Large Coil Test Facility (LCTF) in which the structural response of the Toroidal Field (TF) Coils and the supporting structure was evaluated under simulated reactor conditions. The LCP test facility structural system consists of six TF Coils, twelve coil-to-coil torsional restraining beams (torque rings), a central bucking post with base, and a Pulse Coil system. The NASTRAN Finite Element Structural Analysis computer Code was utilized to determine the distribution of deflections, forces, and stresses for each of the TF Coils, torque rings, and the central bucking post. Eleven load conditions were selected to represent probable test operations. Pulse Coils suspended in the bore of the test coil were energized to simulate the pulsed field environment characteristic of the TNS reactor system. The TORMAC Computer Code was utilized to develop the magnetic forces in the TF Coils for each of the eleven loading conditions examined, with or without the Pulse Coils energized. The TORMAC computer program output forces were used directly as input load conditions for the NASTRAN analyses. Results are presented which demonstrate the reliability of the LCTF under simulated reactor operating conditions

  19. [True aneurysm of the common hepatic artery: a case report].

    Science.gov (United States)

    Mighri, Mohamed Mongi; Boujelbene, Salah; Trabelsi, Khaled; Zouaoui, Taieb; Khemakhem, Abdelhamid; Abid, Skander; Gzara, Kaouther; Chebbi, Fethi; Touinsi, Hassen; Azzouz, Mohamed Moussadek; Sassi, Sadok

    2004-02-01

    We report a case of hepatic artery aneurysm suggested by the appearance of epigastric mass. The diagnosis was confirmed by doppler sonography and helical CT. Surgical excision of the aneurysm without vascular reconstruction was carried out. PMID:15185605

  20. LDV measurements in lateral model aneurysms of various sizes

    Science.gov (United States)

    Liou, T.-M.; Chang, W.-C.; Liao, C.-C.

    Laser Doppler velocimetry (LDV) measurements are presented of three-dimensional flow fields in lateral model aneurysms arising from a straight parent vessel at a 90° angle. The flow considered was pulsatile and the aneurysm wall was rigid. The mean, peak, and minimal Reynolds numbers based on the bulk average velocity and diameter of the parent vessel were 550, 790, and 375, respectively. Comparisons among present in vitro studies, previous in vitro studies, computational simulations, and in vivo studies were made. It was found that the inflow angle into the lateral aneurysm, the maximum wall shear stress acting on the distal lip of the lateral aneurysm, and the intra-aneurysmal vortical motion increased with decreasing aneurysm size. This fact together with the impingement bifurcation of the inflow at the aneurysm dome provide possible hemodynamic factors for the rupture of the lateral aneurysm at small critical size.

  1. Talk to Your Doctor about Abdominal Aortic Aneurysm

    Science.gov (United States)

    ... Print This Topic En español Talk to Your Doctor about Abdominal Aortic Aneurysm Browse Sections The Basics ... Why do I need to talk to the doctor? Aneurysms usually grow slowly without any symptoms. When ...

  2. Aneurysms of the posterior cerebral artery in children

    International Nuclear Information System (INIS)

    Two cases of aneurysms of the posterior cerebral artery, diagnosed by CT and confirmed angiographically, are reported. In the first case, the aneurysm was discovered fortuitously. The second began with intracerebral haemorrhage. A review of the literature is reported. (orig.)

  3. Coil Optimization for HTS Machines

    DEFF Research Database (Denmark)

    Mijatovic, Nenad; Jensen, Bogi Bech; Abrahamsen, Asger Bech; Træholt, Chresten; Pedersen, N.F.; Rodriguez Zermeno, Victor Manuel

    An optimization approach of HTS coils in HTS synchronous machines (SM) is presented. The optimization is aimed at high power SM suitable for direct driven wind turbines applications. The optimization process was applied to a general radial flux machine with a peak air gap flux density of ~3T. The...

  4. Finite element coiled cochlea model

    Science.gov (United States)

    Isailovic, Velibor; Nikolic, Milica; Milosevic, Zarko; Saveljic, Igor; Nikolic, Dalibor; Radovic, Milos; Filipović, Nenad

    2015-12-01

    Cochlea is important part of the hearing system, and thanks to special structure converts external sound waves into neural impulses which go to the brain. Shape of the cochlea is like snail, so geometry of the cochlea model is complex. The simplified cochlea coiled model was developed using finite element method inside SIFEM FP7 project. Software application is created on the way that user can prescribe set of the parameters for spiral cochlea, as well as material properties and boundary conditions to the model. Several mathematical models were tested. The acoustic wave equation for describing fluid in the cochlea chambers - scala vestibuli and scala timpani, and Newtonian dynamics for describing vibrations of the basilar membrane are used. The mechanical behavior of the coiled cochlea was analyzed and the third chamber, scala media, was not modeled because it does not have a significant impact on the mechanical vibrations of the basilar membrane. The obtained results are in good agreement with experimental measurements. Future work is needed for more realistic geometry model. Coiled model of the cochlea was created and results are compared with initial simplified coiled model of the cochlea.

  5. Coupled Coils, Magnets and Lenz's Law

    Science.gov (United States)

    Thompson, Frank

    2010-01-01

    Great scientists in the past have experimented with coils and magnets. Here we have a variation where coupling occurs between two coils and the oscillatory motion of two magnets to give somewhat surprising results. (Contains 6 figures and 1 footnote.)

  6. Isolated common femoral artery aneurysm: a case report

    OpenAIRE

    Sharma, Saurabh; Nalachandran, Sanjay

    2009-01-01

    Introduction Isolated aneurysm of common femoral artery is a rare occurrence. They may mimic other common conditions like groin lymph nodes or groin hernia. Case presentation Here we present a case of 61-years-old Chinese gentleman who presented with a right groin lump, which was suspected to be groin hernia but turned out common femoral artery aneurysm. The aneurysm was surgically excised and a prosthetic vascular repair was done. Conclusion Isolated common femoral artery aneurysms are rare ...

  7. Rupture of popliteal arterial aneurysm due to salmonella infection

    International Nuclear Information System (INIS)

    We report here on a case of popliteal aneurysm and rupture that occurred over a 10-day period and this was all secondary to salmonella infection. Computed tomography (CT) angiography of the extremity that was performed before and after aneurysmal rupture showed the aneurysm's rapid evolution to rupture over a short period of time. We also review the pathogenesis, clinical presentation, diagnostic approach and management of salmonella aneurysms

  8. Distal posterior inferior cerebellar artery aneurysm in a child

    OpenAIRE

    J. FRANCISCO SALOMÃO; René D. Leibinger; Yara M. S. Lima Ciro de A. Cunha; Ilton G. Shinzato; Paulo de T. L. Dantas

    1992-01-01

    The case of a 7-year-old boy presenting with recurrent episodes of subarachnoid hemorrhage due to a distal posterior inferior cerebellar artery aneurysm (PICA), successfully operated, is reported.' The low incidence of intracranial aneurysms in the first decade of life and the rare occurrence of distal PICA aneurysms are unusual features of this case. The theories regarding the origin of intracranial berry aneurysms are discussed.

  9. Clinical Practice Guideline for the Management of Intracranial Aneurysms

    OpenAIRE

    Jeong, Hae Woong; Seo, Jung Hwa; Kim, Sung Tae; Jung, Cheol Kyu; Suh, Sang-il

    2014-01-01

    Purpose An intracranial aneurysm, with or without subarachnoid hemorrhage (SAH), is a relevant health problem. The rupture of an intracranial aneurysm is a critical concern for individual health; even an unruptured intracranial aneurysm is an anxious condition for the individual. The aim of this guideline is to present current and comprehensive recommendations for the management of intracranial aneurysms, with or without rupture. Materials and Methods We performed an extensive literature sear...

  10. Traumatic aneurysms of the intracranial and cervical vessels: A review

    Directory of Open Access Journals (Sweden)

    Kamlesh S Bhaisora

    2016-01-01

    Full Text Available Traumatic intracranial aneurysms (TICA are rare in occurrence, constituting less than 1% of the total cases of intracranial aneurysms. Cervical posttraumatic aneurysms arising from major blood vessels supplying the brain are also extremely rare. Their variable locations, morphological variations and the presence of concomitant head injury makes their diagnosis and treatment a challenge. In this review, we discuss the epidemiology, etiology, classification and management issues related to TICA as well as traumatic neck aneurysms and review the pertinent literature.

  11. Rotor assembly including superconducting magnetic coil

    Science.gov (United States)

    Snitchler, Gregory L.; Gamble, Bruce B.; Voccio, John P.

    2003-01-01

    Superconducting coils and methods of manufacture include a superconductor tape wound concentrically about and disposed along an axis of the coil to define an opening having a dimension which gradually decreases, in the direction along the axis, from a first end to a second end of the coil. Each turn of the superconductor tape has a broad surface maintained substantially parallel to the axis of the coil.

  12. Design and modelling of a SMES coil

    International Nuclear Information System (INIS)

    The design of a Superconducting Magnetic Energy Storage (SMES) coil wound by coated conductors has been presented. Based on an existing model for coated conductor pancake coils, this paper analysed the magnetic field and current density distribution of the coil at two different operation temperatures, 77K and 22K. A comparison table of the critical currents and AC losses at these two temperatures has been presented. Several steps to improve the transport current of the coil have been suggested as well.

  13. Design and modelling of a SMES coil

    Science.gov (United States)

    Yuan, Weijia; Campbell, A. M.; Coombs, T. A.

    2010-06-01

    The design of a Superconducting Magnetic Energy Storage (SMES) coil wound by coated conductors has been presented. Based on an existing model for coated conductor pancake coils, this paper analysed the magnetic field and current density distribution of the coil at two different operation temperatures, 77K and 22K. A comparison table of the critical currents and AC losses at these two temperatures has been presented. Several steps to improve the transport current of the coil have been suggested as well.

  14. Marfan's syndrome and isolated aneurysm of the abdominal aorta.

    OpenAIRE

    Van Ooijen, B.

    1988-01-01

    A 43 year old woman presented with an aneurysm of the abdominal aorta. Marfan's syndrome was diagnosed as the underlying cause of the aneurysm. An isolated aneurysm as presenting sign of Marfan's syndrome is rare. In a review of published reports about 30 cases were found.

  15. A Fatal Case of Klebsiella pneumoniae Mycotic Aneurysm

    OpenAIRE

    Chien-Ming Chao; Kun-Kuang Lee; Chia-Sheng Wang; Ping-Jen Chen; Tsung-Chih Yeh

    2011-01-01

    Mycotic aneurysm is a serious clinical condition with significant morbidity and mortality. Staphylococcus aureus and Salmonella species are the most common causative pathogens. Klebsiella pneumoniae was rarely reported as a possible pathogen causing mycotic aneurysm; therefore, we describe a K. pneumoniae-related fatal bacteremia mycotic aneurysm in a patient in spite of appropriate antimicrobial agents and surgical management.

  16. Unruptured sinus of Valsalva aneurysm involving all three sinuses.

    Science.gov (United States)

    Altarabsheh, Salah Eldien I; Araoz, Philip A; Deo, Salil V; Sundt, Thoralf M

    2011-02-01

    In contrast to generalized aneurysmal dilatation of the aortic root, discrete sinus of Valsalva aneurysm is an uncommon condition most often affecting the right coronary sinus. We recently treated a patient without the known connective tissue disorder having discrete aneurysms of all three sinuses. PMID:21256260

  17. Development of SMART CRDM Coil Design

    International Nuclear Information System (INIS)

    A control rod drive mechanism (CRDM) is an electromagnetic device which drives a control rod assembly linearly to regulate reactivity of a nuclear core. Driving force is electromagnetic force generated from coils installed outside of a motor housing. The magnetic parts of a motor assembly installed inside of a motor housing are magnetized when a coil is activated, and adhere to each other to produce latching or driving force as a result. A coil assembly consists of a lifting coil, a movable latch coil and a stationary latch coil as shown in Fig. 1. The latch coils make a drive shaft engaged with or released from latches, and the lift coil makes a drive shaft and a control rod assembly move up or drop. A CRDM control system supplies controlled electric current to a specified coil in order, and then a control rod assembly moves up or down. The coil assembly for SMART CRDM has been developed based on the design concept of a coil assembly for control element drive mechanism (CEDM) of the OPR1000, and modified to satisfy dedicated design requirements for SMART reactor. Some of representative design requirements are the lifting capacity of 3200N which is greater, the lifting step of 15.875mm which is longer than that for CEDM, and one step driving instead of two step driving. Design process through an electromagnetic analysis for a lift coil is described herein as a representative example, and representative results of the analysis are presented

  18. Inductively coupled wireless RF coil arrays.

    Science.gov (United States)

    Bulumulla, S B; Fiveland, E; Park, K J; Foo, T K; Hardy, C J

    2015-04-01

    As the number of coils increases in multi-channel MRI receiver-coil arrays, RF cables and connectors become increasingly bulky and heavy, degrading patient comfort and slowing workflow. Inductive coupling of signals provides an attractive "wireless" approach, with the potential to reduce coil weight and cost while simplifying patient setup. In this work, multi-channel inductively coupled anterior arrays were developed and characterized for 1.5T imaging. These comprised MR receiver coils inductively (or "wirelessly") linked to secondary or "sniffer" coils whose outputs were transmitted via preamps to the MR system cabinet. The induced currents in the imaging coils were blocked by passive diode circuits during RF transmit. The imaging arrays were totally passive, obviating the need to deliver power to the coils, and providing lightweight, untethered signal reception with easily positioned coils. Single-shot fast spin echo images were acquired from 5 volunteers using a 7-element inductively coupled coil array and a conventionally cabled 7-element coil array of identical geometry, with the inductively-coupled array showing a relative signal-to-noise ratio of 0.86 +/- 0.07. The concept was extended to a larger 9-element coil array to demonstrate the effect of coil element size on signal transfer and RF-transmit blocking. PMID:25523607

  19. Cloning, overexpression, purification and crystallization of the CRN12 coiled-coil domain from Leishmania donovani

    OpenAIRE

    Srivastava, Vijay Kumar; Rana, Ajay Kumar; Sahasrabuddhe, Amogh A.; Gupta, C M; Pratap, J.V.

    2013-01-01

    The L. donovani coronin CRN12 coiled-coil domain (5.8 kDa) was cloned, overexpressed and purified to homogeneity. Crystals of recombinant L. donovani coronin CRN12 coiled-coil domain were grown by vapour diffusion using a hanging-drop setup.

  20. Self-assembly of designed coiled coil peptides studied by small-angle X-ray scattering and analytical ultracentrifugation

    DEFF Research Database (Denmark)

    Malik, Leila; Nygaard, Jesper; Christensen, Niels Johan;

    2013-01-01

    α-Helical coiled coil structures, which are noncovalently associated heptad repeat peptide sequences, are ubiquitous in nature. Similar amphipathic repeat sequences have also been found in helix-containing proteins and have played a central role in de novo design of proteins. In addition, they ar...... difference in these methods was observed, as SAXS for one peptide and revealed the presence of a population of longer aggregates, which was not observed by AUC. © 2013 European Peptide Society and John Wiley & Sons, Ltd....