WorldWideScience

Sample records for analytical tem comparisons

  1. Analytical TEM investigations of nanoscale magnetic materials

    International Nuclear Information System (INIS)

    Meingast, A.

    2015-01-01

    Analytical transmission electron microscopy has been applied within this thesis to investigate several novel approaches to design and fabricate nanoscale magnetic materials. As the size of the features of interest rank in the sub-nanometer range, it is necessary to employ techniques with a resolution – both spatial and analytical – well below this magnitude. Only at this performance level it is possible to examine material properties, necessary for the further tailoring of materials. Within this work two key aspects have been covered: First, analytical TEM (transmission electron microscopy) investigations were carried out to get insight into novel magnetic materials with high detail. Second, new analytical and imaging possibilities enabled with the commissioning of the new ASTEM (Austrian scanning transmission electron microscope) were explored. The aberration corrected TITAN® microscope (© FEI Company) allows resolving features in scanning transmission mode (STEM) with 70 pm distance. Thereby, direct imaging of light elements in STEM mode by using the annular bright field method becomes possible. Facilitated through high beam currents within the electron probe, an increased acquisition speed of analytical signals is possible. For energy dispersive X-ray spectroscopy (EDXS) a new four detector disc geometry around the specimen was implemented, which increases the accessible collection angle. With the integration of the latest generation of image filter and electron spectrometer (GIF QuantumERS), electron energy loss spectroscopy (EELS) is boosted through the high acquisition speed and the dual spectroscopy mode. The high acquisition speed allows to record up to 1000 spectra per second and the possibility to record atomically resolved EELS maps is at hand. Hereby it is important to avoid beam damage and alteration of the material during imaging and analysis. With the simultaneous acquisition of the low and the high loss spectral region, an extended range for

  2. A short note on how to convert a conventional analytical TEM into an analytical Low Voltage TEM

    International Nuclear Information System (INIS)

    Stöger-Pollach, M.

    2014-01-01

    The present work is a short note on the performance of a conventional transmission electron microscope (TEM) being operated at very low beam energies (below 20 keV). We discuss the high tension stability and resolving power of this uncorrected TEM. We find out that the theoretical lens performance can nearly be achieved in practice. We also demonstrate that electron energy loss spectra can be recorded at these low beam energies with standard equipment. The signal-to-noise ratio is sufficiently good for further data treatment like multiple scattering deconvolution and Kramers–Kronig analysis. - Highlights: • TEM operation at very low beam energies (below 20 keV). • Testing of hardware performance at low beam energies. • EELS spectra recorded with 10 keV electrons

  3. TEM turbulence optimisation in stellarators

    Science.gov (United States)

    Proll, J. H. E.; Mynick, H. E.; Xanthopoulos, P.; Lazerson, S. A.; Faber, B. J.

    2016-01-01

    With the advent of neoclassically optimised stellarators, optimising stellarators for turbulent transport is an important next step. The reduction of ion-temperature-gradient-driven turbulence has been achieved via shaping of the magnetic field, and the reduction of trapped-electron mode (TEM) turbulence is addressed in the present paper. Recent analytical and numerical findings suggest TEMs are stabilised when a large fraction of trapped particles experiences favourable bounce-averaged curvature. This is the case for example in Wendelstein 7-X (Beidler et al 1990 Fusion Technol. 17 148) and other Helias-type stellarators. Using this knowledge, a proxy function was designed to estimate the TEM dynamics, allowing optimal configurations for TEM stability to be determined with the STELLOPT (Spong et al 2001 Nucl. Fusion 41 711) code without extensive turbulence simulations. A first proof-of-principle optimised equilibrium stemming from the TEM-dominated stellarator experiment HSX (Anderson et al 1995 Fusion Technol. 27 273) is presented for which a reduction of the linear growth rates is achieved over a broad range of the operational parameter space. As an important consequence of this property, the turbulent heat flux levels are reduced compared with the initial configuration.

  4. Comparison of soil sampling and analytical methods for asbestos at the Sumas Mountain Asbestos Site-Working towards a toolbox for better assessment.

    Science.gov (United States)

    Wroble, Julie; Frederick, Timothy; Frame, Alicia; Vallero, Daniel

    2017-01-01

    Established soil sampling methods for asbestos are inadequate to support risk assessment and risk-based decision making at Superfund sites due to difficulties in detecting asbestos at low concentrations and difficulty in extrapolating soil concentrations to air concentrations. Environmental Protection Agency (EPA)'s Office of Land and Emergency Management (OLEM) currently recommends the rigorous process of Activity Based Sampling (ABS) to characterize site exposures. The purpose of this study was to compare three soil analytical methods and two soil sampling methods to determine whether one method, or combination of methods, would yield more reliable soil asbestos data than other methods. Samples were collected using both traditional discrete ("grab") samples and incremental sampling methodology (ISM). Analyses were conducted using polarized light microscopy (PLM), transmission electron microscopy (TEM) methods or a combination of these two methods. Data show that the fluidized bed asbestos segregator (FBAS) followed by TEM analysis could detect asbestos at locations that were not detected using other analytical methods; however, this method exhibited high relative standard deviations, indicating the results may be more variable than other soil asbestos methods. The comparison of samples collected using ISM versus discrete techniques for asbestos resulted in no clear conclusions regarding preferred sampling method. However, analytical results for metals clearly showed that measured concentrations in ISM samples were less variable than discrete samples.

  5. Electromagnetic survey (TEM method) in Teradomari and examination of resistivity structure to be based on near surface information; Niigataken Teradomarimachi ni okeru denji tansa kekka (TEM ho) no doshitsu joho ni yoru kento

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, H; Mitsuhata, Y; Matsuo, K; Tanaka, H [Japan National Oil Corp., Tokyo (Japan). Technology Research Center; Wada, K [Mitsui Mineral Development Engineering Co. Ltd., Tokyo (Japan)

    1996-10-01

    TEM method was applied to estimate soil structure from resistivity change of underground water saturated stratum featured by slow S wave and fast P wave over 1500m/s. Vertical magnetic field was measured by underlaying a transmission loop of 60m{times}60m around a measuring point in Teradomari, Niigata prefecture, and by installing a magnetic sensor at the measuring point. From comparison of a soil profile with the resistivity profile obtained by TEM data, the former well consisted with the latter. The surface low resistivity stratum corresponded to alluvium from comparison of it with soil and logging data. This alluvium base with fast P wave over 1500m/s satisfied the condition of optimum blasting depth because of a saturated stratum in the surface base. The resistivity structure was related to a saturated stratum. Sand bed was thick at the interface between alluvium low ground and hill area, and from the analytical result, the depth of sand bed showing high resistivity was more shallow than that of the alluvium base, pointing out necessary notice in interpretation. Resistivity survey is promising as simple method for optimum blasting depth. 4 refs., 6 figs., 1 tab.

  6. Solar Ion Processing of Major Element Surface Compositions of Mature Mare Soils: Insights from Combined XPS and Analytical TEM Observations

    Science.gov (United States)

    Christoffersen, R.; Dukes, C.; Keller, L. P.; Baragiola, R.

    2012-01-01

    Solar wind ions are capable of altering the sur-face chemistry of the lunar regolith by a number of mechanisms including preferential sputtering, radiation-enhanced diffusion and sputter erosion of space weathered surfaces containing pre-existing compositional profiles. We have previously reported in-situ ion irradiation experiments supported by X-ray photoelectron spectroscopy (XPS) and analytical TEM that show how solar ions potentially drive Fe and Ti reduction at the monolayer scale as well as the 10-100 nm depth scale in lunar soils [1]. Here we report experimental data on the effect of ion irradiation on the major element surface composition in a mature mare soil.

  7. TEM-turbulence in stellarators and its optimization

    Science.gov (United States)

    Proll, Josefine H. E.; Helander, Per; Lazerson, Samuel; Mynick, Harry; Xanthopoulos, Pavlos

    2014-10-01

    Quasi-isodynamic stellarators, which are especially optimized for neoclassical transport, have been shown to be resilient towards trapped-electrons modes (TEMs) in large regions of parameter space. In these configurations, all particles have average ``good curvature.'' It was shown analytically that, thanks to this property, particles that bounce faster than the mode in question draw energy from it near marginal stability, so that the ordinary density-gradient-driven TEM has to be stable in the electrostatic and collisionless limit.This has been confirmed in linear flux-tube simulations that were performed with the GENE code. Several magnetic field configurations were compared and it was found that the growth rates of the TEMs drop with increasing degree of quasi-isodynamicity. These findings can be used to optimize stellarators with respect to TEM turbulence by reducing the fraction of trapped particles with bounce averaged ``bad curvature.'' An appropriate proxy function has therefore been designed to be implemented in STELLOPT, a stellarator optimization tool that can now be used to further explore the configuration space of neoclassically optimized stellarators with the aim to extract designs with improved turbulent transport. This work was facilitated by the Max-Planck/Princeton Center for Plasma Physics.

  8. Comparison between measured and predicted turbulence frequency spectra in ITG and TEM regimes

    Science.gov (United States)

    Citrin, J.; Arnichand, H.; Bernardo, J.; Bourdelle, C.; Garbet, X.; Jenko, F.; Hacquin, S.; Pueschel, M. J.; Sabot, R.

    2017-06-01

    The observation of distinct peaks in tokamak core reflectometry measurements—named quasi-coherent-modes (QCMs)—are identified as a signature of trapped-electron-mode (TEM) turbulence (Arnichand et al 2016 Plasma Phys. Control. Fusion 58 014037). This phenomenon is investigated with detailed linear and nonlinear gyrokinetic simulations using the Gene code. A Tore-Supra density scan is studied, which traverses through a linear (LOC) to saturated (SOC) ohmic confinement transition. The LOC and SOC phases are both simulated separately. In the LOC phase, where QCMs are observed, TEMs are robustly predicted unstable in linear studies. In the later SOC phase, where QCMs are no longer observed, ion-temperature-gradient (ITG) modes are identified. In nonlinear simulations, in the ITG (SOC) phase, a broadband spectrum is seen. In the TEM (LOC) phase, a clear emergence of a peak at the TEM frequencies is seen. This is due to reduced nonlinear frequency broadening of the underlying linear modes in the TEM regime compared with the ITG regime. A synthetic diagnostic of the nonlinearly simulated frequency spectra reproduces the features observed in the reflectometry measurements. These results support the identification of core QCMs as an experimental marker for TEM turbulence.

  9. Objective function analysis for electric soundings (VES), transient electromagnetic soundings (TEM) and joint inversion VES/TEM

    Science.gov (United States)

    Bortolozo, Cassiano Antonio; Bokhonok, Oleg; Porsani, Jorge Luís; Monteiro dos Santos, Fernando Acácio; Diogo, Liliana Alcazar; Slob, Evert

    2017-11-01

    Ambiguities in geophysical inversion results are always present. How these ambiguities appear in most cases open to interpretation. It is interesting to investigate ambiguities with regard to the parameters of the models under study. Residual Function Dispersion Map (RFDM) can be used to differentiate between global ambiguities and local minima in the objective function. We apply RFDM to Vertical Electrical Sounding (VES) and TEM Sounding inversion results. Through topographic analysis of the objective function we evaluate the advantages and limitations of electrical sounding data compared with TEM sounding data, and the benefits of joint inversion in comparison with the individual methods. The RFDM analysis proved to be a very interesting tool for understanding the joint inversion method of VES/TEM. Also the advantage of the applicability of the RFDM analyses in real data is explored in this paper to demonstrate not only how the objective function of real data behaves but the applicability of the RFDM approach in real cases. With the analysis of the results, it is possible to understand how the joint inversion can reduce the ambiguity of the methods.

  10. Speciation of uranium in minerals by Sem, Tem, μ-PIXE, XPS and XAFS

    International Nuclear Information System (INIS)

    Toshihiko Ohnuki; Hiroshi Isobe; Tomihiro Kamiya; Takuro Sakai; Takashi Murakami

    2001-01-01

    Many kinds of electromagnetic waves and particle beams are used as analytical probes for the investigation of uranium-mineralogy and speciation. The representatives of the probes are SEM, TEM, μ-PIRE, XPS and XAFS. Each of these analytical probes has its own advantages and disadvantages. We have performed studies to compare the advantages and disadvantages on the basis of the analysis of the distribution and speciation of U containing rock samples collected at the Koongarra uranium deposit, Australia. The spatial resolutions of the probes are in the order of TEM>SEM, μ-PIXE>XFAS, XPS. The lower detection limits of the probes are in the order of μ-PIXE< TEM, SEM< XFAS, XPS. Oxidation state of U was determined by XFAS and XPS. These results indicate that combination of the above probes can give us sufficient data on U speciation not only in natural rock samples but in solid samples obtained in the laboratory. (authors)

  11. Developments in TEM Nanotomography of Calcium Silicate Hydrate

    KAUST Repository

    Taylor, Rae; Sakdinawat, Anne E.; Chae, Sejung R.; Wenk, Haz Rudolf; Levitz, Pierre E.; Sougrat, Rachid; Monteiro, Paulo José Meleragno

    2015-01-01

    This investigation was designed to explore the possibility of using transmission electron microscope (TEM) tomography on cement-based systems gain a greater understanding of their nanostructure and pore network. The preliminary results show a clearly a well-defined pore network at the nanoscale, with pore size approximately 1.7-2.4 nm in diameter and spaced around 5-8 nm apart. A comparison of small angle X-ray scattering data with 2-D TEM images analyzed with the Fourier slice theorem documents an excellent structural correlation. © 2015 The American Ceramic Society.

  12. Developments in TEM Nanotomography of Calcium Silicate Hydrate

    KAUST Repository

    Taylor, Rae

    2015-04-01

    This investigation was designed to explore the possibility of using transmission electron microscope (TEM) tomography on cement-based systems gain a greater understanding of their nanostructure and pore network. The preliminary results show a clearly a well-defined pore network at the nanoscale, with pore size approximately 1.7-2.4 nm in diameter and spaced around 5-8 nm apart. A comparison of small angle X-ray scattering data with 2-D TEM images analyzed with the Fourier slice theorem documents an excellent structural correlation. © 2015 The American Ceramic Society.

  13. Destructive interference of TEM and ITG turbulence

    International Nuclear Information System (INIS)

    Merz, F.; Jenko, F.

    2009-01-01

    Full text: Turbulence driven by ion temperature gradient (ITG) modes and trapped electron modes (TEMs) is generally considered the key mechanism for anomalous transport in fusion devices on ion scales. But while pure ITG and, to a lesser extent, also pure TEM turbulence have been studied in detail over the last years, not much is presently known about nonlinear interactions between ITG modes and TEMs, which are often present simultaneously in experimentally relevant situations. This important issue is addressed by means of linear and nonlinear gyrokinetic simulations with the GENE code. To examine the properties of the (linear) TEM and ITG instabilities in the (realistic) transitional regime, the GENE code is run as eigenvalue solver, which allows for a systematic study of dominant and subdominant modes. Corresponding nonlinear initial value computations show that the particle transport of the turbulent system can be completely suppressed if the two driving instabilities are active simultaneously. The direct comparison of the linear modes and the corresponding turbulent system reveals a coexistence of the two microinstabilities in a transitional regime even at the same wave number. The consequences of this dual turbulence drive for transport modeling is discussed. (author)

  14. Analytical Electron Microscope

    Data.gov (United States)

    Federal Laboratory Consortium — The Titan 80-300 is a transmission electron microscope (TEM) equipped with spectroscopic detectors to allow chemical, elemental, and other analytical measurements to...

  15. A comparison of verbal and numerical judgments in the analytic hierarchy process

    NARCIS (Netherlands)

    Huizingh, EKRE; Vrolijk, HCJ

    In the Analytic Hierarchy Process (AHP), decision makers make pairwise comparisons of alternatives and criteria. The AHP allows to make these pairwise comparisons verbally or numerically. Although verbal statements are intuitively attractive for preference elicitation, there is overwhelming evidence

  16. Comparison of ultramicrotomy and focused-ion-beam for the preparation of TEM and STEM cross section of organic solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Corazza, Michael, E-mail: michael.corazza@gmail.com [Department of Energy Conversion and Storage, Technical University of Denmark, Frederiksborgvej 399, 4000 Roskilde (Denmark); Simonsen, Søren B. [Department of Energy Conversion and Storage, Technical University of Denmark, Frederiksborgvej 399, 4000 Roskilde (Denmark); Gnaegi, Helmut [Diatome Ltd., Biel-Bienne (Switzerland); Thydén, Karl T.S.; Krebs, Frederik C.; Gevorgyan, Suren A. [Department of Energy Conversion and Storage, Technical University of Denmark, Frederiksborgvej 399, 4000 Roskilde (Denmark)

    2016-12-15

    Highlights: • Comparison of flexible solar cell sections prepared by ultramicrotomy and by FIB. • Energy filtered TEM analysis of phase separation in the P3HT:PCBM active layer. • Imaging of aging effects on solar cell cross section prepared by ultramicrotomy. • Ultramicrotomy provides great details while FIB better preserves the structure. - Abstract: The challenge of preparing cross sections of organic photovoltaics (OPV) suitable for transmission electron microscopy (TEM) and scanning TEM (STEM) is addressed. The samples were polymer solar cells fabricated using roll-to-roll (R2R) processing methods on a flexible polyethylene terephthalate (PET) substrate. Focused ion beam (FIB) and ultramicrotomy were used to prepare the cross sections. The differences between the samples prepared by ultramicrotomy and FIB are addressed, focusing on the advantages and disadvantages of each technique. The sample prepared by ultramicrotomy yielded good resolution, enabling further studies of phase separation of P3HT:PCBM by means of energy filtered TEM (EFTEM). The sample prepared by FIB shows good structure preservation, but reduced resolution due to non-optimal thicknesses achieved after treatment. Degradation studies of samples prepared by ultramicrotomy are further discussed, which reveal particular effects of the ISOS-L-3 aging test (85 °C, 50% R.H., 0.7 Sun) onto the sample, especially pronounced in the silver layer.

  17. Effect of interparticle interactions on size determination of zirconia and silica based systems – A comparison of SAXS, DLS, BET, XRD and TEM

    Science.gov (United States)

    Pabisch, Silvia; Feichtenschlager, Bernhard; Kickelbick, Guido; Peterlik, Herwig

    2012-01-01

    The aim of this work is a systematic comparison of size characterisation methods for two completely different model systems of oxide nanoparticles, i.e. amorphous spherical silica and anisotropic facet-shaped crystalline zirconia. Size and/or size distribution were determined in a wide range from 5 to 70 nm using small-angle X-ray scattering (SAXS), dynamic light scattering (DLS), nitrogen sorption (BET), X-ray diffraction (XRD) and transmission electron microscopy (TEM). A nearly perfect coincidence was observed only for SAXS and TEM for both types of particles. For zirconia nanoparticles considerable differences between different measurement methods were observed. PMID:22347721

  18. In situ TEM electromechanical testing of nanowires and nanotubes.

    Science.gov (United States)

    Espinosa, Horacio D; Bernal, Rodrigo A; Filleter, Tobin

    2012-11-05

    The emergence of one-dimensional nanostructures as fundamental constituents of advanced materials and next-generation electronic and electromechanical devices has increased the need for their atomic-scale characterization. Given its spatial and temporal resolution, coupled with analytical capabilities, transmission electron microscopy (TEM) has been the technique of choice in performing atomic structure and defect characterization. A number of approaches have been recently developed to combine these capabilities with in-situ mechanical deformation and electrical characterization in the emerging field of in-situ TEM electromechanical testing. This has enabled researchers to establish unambiguous synthesis-structure-property relations for one-dimensional nanostructures. In this article, the development and latest advances of several in-situ TEM techniques to carry out mechanical and electromechanical testing of nanowires and nanotubes are reviewed. Through discussion of specific examples, it is shown how the merging of several microsystems and TEM has led to significant insights into the behavior of nanowires and nanotubes, underscoring the significant role in-situ techniques play in the development of novel nanoscale systems and materials. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Determination of Size Distributions in Nanocrystalline Powders by TEM, XRD and SAXS

    DEFF Research Database (Denmark)

    Jensen, Henrik; Pedersen, Jørgen Houe; Jørgensen, Jens Erik

    2006-01-01

    Crystallite size distributions and particle size distributions were determined by TEM, XRD, and SAXS for three commercially available TiO2 samples and one homemade. The theoretical Guinier Model was fitted to the experimental data and compared to analytical expressions. Modeling of the XRD spectra...... the size distribution obtained from the XRD experiments; however, a good agreement was obtained between the two techniques. Electron microscopy, SEM and TEM, confirmed the primary particle sizes, the size distributions, and the shapes obtained by XRD and SAXS. The SSEC78 powder and the commercially...

  20. TEM specimen preparation of semiconductor-PMMA-metal interfaces

    International Nuclear Information System (INIS)

    Thangadurai, P.; Lumelsky, Yulia; Silverstein, Michael S.; Kaplan, Wayne D.

    2008-01-01

    Transmission electron microscopy (TEM) cross-section specimens of PMMA in contact with gold and Si were prepared by focused ion beam (FIB) and compared with plan-view PMMA specimens prepared by a dip-coating technique. The specimens were characterized by TEM and electron energy loss spectroscopy (EELS). In the cross-section specimens, the thin films of PMMA were located in a Si-PMMA-Au multilayer. Different thicknesses of PMMA films were spin-coated on the Si substrates. The thickness of the TEM specimens prepared by FIB was estimated using EELS to be 0.65 of the plasmon mean-free-path. Along the PMMA-Au interface, Au particle diffusion into the PMMA was observed, and the size of the Au particles was in the range of 2-4 nm. Dip-coating of PMMA directly on Cu TEM grids resulted in thin specimens with a granular morphology, with a thickness of 0.58 of the plasmon mean-free-path. The dip-coated specimens were free from ion milling induced artifacts, and thus serve as control specimens for comparison with the cross-sectioned specimens prepared by FIB

  1. GISAXS modelling of helium-induced nano-bubble formation in tungsten and comparison with TEM

    International Nuclear Information System (INIS)

    Thompson, Matt; Sakamoto, Ryuichi; Bernard, Elodie; Kirby, Nigel; Kluth, Patrick; Riley, Daniel; Corr, Cormac

    2016-01-01

    Grazing-incidence small angle x-ray scattering (GISAXS) is a powerful non-destructive technique for the measurement of nano-bubble formation in tungsten under helium plasma exposure. Here, we present a comparative study between transmission electron microscopy (TEM) and GISAXS measurements of nano-bubble formation in tungsten exposed to helium plasma in the Large Helical Device (LHD) fusion experiment. Both techniques are in excellent agreement, suggesting that nano-bubbles range from spheroidal to ellipsoidal, displaying exponential diameter distributions with mean diameters μ=0.68 ± 0.04 nm and μ=0.6 ± 0.1 nm measured by TEM and GISAXS respectively. Depth distributions were also computed, with calculated exponential depth distributions with mean depths of 8.4 ± 0.5 nm and 9.1 ± 0.4 nm for TEM and GISAXS. In GISAXS modelling, spheroidal particles were fitted with an aspect ratio ε=0.7 ± 0.1. The GISAXS model used is described in detail. - Highlights: • GISAXS and TEM were used to measure nano-bubble formation in W exposed to He plasma in the large helical device. • Nano-bubbles had an exponential diameter distributions with averages 0.6 ± 0.1 nm and 0.68 ± 0.04 nm measured by GISAXS and TEM. • Nano-bubbles had an exponential depth distributions with average depths of 9.1 ± 0.4 nm and 8.4 ± 0.5 nm for GISAXS and TEM. • The GISAXS model used to analyse diffraction patterns is explained in detail.

  2. GISAXS modelling of helium-induced nano-bubble formation in tungsten and comparison with TEM

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Matt, E-mail: matt.a.thompson@anu.edu.au [Research School of Physics and Engineering, Australian National University, Mills Road, Acton, ACT 2601 (Australia); Sakamoto, Ryuichi [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Bernard, Elodie [Aix-Marseille University, Marseille 13288 (France); Kirby, Nigel [SAXS/WAXS Beamline, Australian Synchrotron, 800 Blackburn Rd, Clayton, VIC, 3168 (Australia); Kluth, Patrick [Research School of Physics and Engineering, Australian National University, Mills Road, Acton, ACT 2601 (Australia); Riley, Daniel [Australian Nuclear Science and Technology Organisation, Locked Bag 2001, Kirrawee DC, NSW, 2232 (Australia); Corr, Cormac [Research School of Physics and Engineering, Australian National University, Mills Road, Acton, ACT 2601 (Australia)

    2016-05-15

    Grazing-incidence small angle x-ray scattering (GISAXS) is a powerful non-destructive technique for the measurement of nano-bubble formation in tungsten under helium plasma exposure. Here, we present a comparative study between transmission electron microscopy (TEM) and GISAXS measurements of nano-bubble formation in tungsten exposed to helium plasma in the Large Helical Device (LHD) fusion experiment. Both techniques are in excellent agreement, suggesting that nano-bubbles range from spheroidal to ellipsoidal, displaying exponential diameter distributions with mean diameters μ=0.68 ± 0.04 nm and μ=0.6 ± 0.1 nm measured by TEM and GISAXS respectively. Depth distributions were also computed, with calculated exponential depth distributions with mean depths of 8.4 ± 0.5 nm and 9.1 ± 0.4 nm for TEM and GISAXS. In GISAXS modelling, spheroidal particles were fitted with an aspect ratio ε=0.7 ± 0.1. The GISAXS model used is described in detail. - Highlights: • GISAXS and TEM were used to measure nano-bubble formation in W exposed to He plasma in the large helical device. • Nano-bubbles had an exponential diameter distributions with averages 0.6 ± 0.1 nm and 0.68 ± 0.04 nm measured by GISAXS and TEM. • Nano-bubbles had an exponential depth distributions with average depths of 9.1 ± 0.4 nm and 8.4 ± 0.5 nm for GISAXS and TEM. • The GISAXS model used to analyse diffraction patterns is explained in detail.

  3. Streptomyces sp. TEM 33 possesses high lipolytic activity in solid-state fermentation in comparison with submerged fermentation.

    Science.gov (United States)

    Cadirci, Bilge Hilal; Yasa, Ihsan; Kocyigit, Ali

    2016-01-01

    Solid-state fermentation (SSF) is a bioprocess that doesn't need an excess of free water, and it offers potential benefits for microbial cultivation for bioprocesses and product development. In comparing the antibiotic production, few detailed reports could be found with lipolytic enzyme production by Streptomycetes in SSF. Taking this knowledge into consideration, we prefer to purify Actinomycetes species as a new source for lipase production. The lipase-producing strain Streptomyces sp. TEM 33 was isolated from soil and lipase production was managed by solid-state fermentation (SSF) in comparison with submerged fermentation (SmF). Bioprocess-affecting factors like initial moisture content, incubation time, and various carbon and nitrogen additives and the other enzymes secreted into the media were optimized. Lipase activity was measured as 1.74 ± 0.0005 U/g dry substrate (gds) by the p-nitrophenylpalmitate (pNPP) method on day 6 of fermentation with 71.43% final substrate moisture content. In order to understand the metabolic priority in SSF, cellulase and xylanase activity of Streptomyces sp. TEM33 was also measured. The microorganism degrades the wheat bran to its usable form by excreting cellulases and xylanases; then it secretes the lipase that is necessary for degrading the oil in the medium.

  4. Analytical and experimental comparisons of modal properties of a flood water storage tank

    International Nuclear Information System (INIS)

    Thinnes, G.L.; Dooley, W.T.; Gorman, V.W.

    1986-01-01

    Comparisons of measured frequencies, mode shapes, and damping from experimental modal testing and analytical predictions have been performed on a vertically standing 90,000 liter flood water storage tank. The purpose of the study was to compare the accuracy of analytical calculations with experimentally obtained data. The need for this comparison arises because safety assessments of the integrity of such vessels are normally based upon analyses which have not usually been validated by experiments. The tank was excited using random input from an electromagnetic shaker. Data reduction was performed using frequency response functions. Analyses, including modal analysis calculations, were performed on the tank for three water level conditions using finite element methods. Results of the analyses are presented, comparisons to test data are shown, and conclusions and recommendations are made as a result of these studies. 5 refs., 8 figs., 2 tabs

  5. Tem study of thermal ageing of ferrite in cast duplex stainless steel

    International Nuclear Information System (INIS)

    Nenonen, P.; Massoud, J.P.; Timofeev, B.T.

    2002-01-01

    The changes in the microstructure and composition of ferrite in two types of cast duplex stainless steels and in an austenitic-ferritic weld metal after long term thermal ageing has been studied using analytical transmission electron microscope (FEGTEM). A cast test steel containing Mo was investigated first as a reference material in three different conditions: as solution annealed, aged at 300 C and aged at 400 C. This investigation was carried out to gain experience of how EDS (X-ray analyser) analyser and TEM (transmission electron microscope) can be used to study elemental inhomogeneity, which is usually investigated with an atom probe (APFIM). The two other materials, an austenitic-ferritic weld metal and a cast duplex Ti-stabilised stainless steel used for long time at NPP operation temperature were investigated using the experience obtained with the test steel. The results showed that analytical TEM can be used to investigate elemental inhomogeneity of ferrite, but there are several important things to be taken into account when the spectra for this purpose are collected. These things are, such as the thickness of the specimen, probe size, contamination rate, 'elemental background' of the spectrum and possible enrichment of certain alloying elements in the surface oxide layer of the TEM-specimens. If minor elements are also analysed, it may increase the scattering of the results. (authors)

  6. New constraints on deformation processes in serpentinite from sub-micron Raman Spectroscopy and TEM

    Science.gov (United States)

    Smith, S. A. F.; Tarling, M.; Rooney, J. S.; Gordon, K. C.; Viti, C.

    2017-12-01

    Extensive work has been performed to characterize the mineralogical and mechanical properties of the various serpentine minerals (i.e. antigorite, lizardite, chrysotile, polyhedral and polygonal serpentine). However, correct identification of serpentine minerals is often difficult or impossible using conventional analytical techniques such as optical- and SEM-based microscopy, X-ray diffraction and infrared spectroscopy. Transmission Electron Microscopy (TEM) is the best analytical technique to identify the serpentine minerals, but TEM requires complex sample preparation and typically results in very small analysis areas. Sub-micron confocal Raman spectroscopy mapping of polished thin sections provides a quick and relatively inexpensive way of unambiguously distinguishing the main serpentine minerals within their in-situ microstructural context. The combination of high spatial resolution (with a diffraction-limited system, 366 nm), large-area coverage (up to hundreds of microns in each dimension) and ability to map directly on thin sections allows intricate fault rock textures to be imaged at a sample-scale, which can then form the target of more focused TEM work. The potential of sub-micron Raman Spectroscopy + TEM is illustrated by examining sub-micron-scale mineral intergrowths and deformation textures in scaly serpentinites (e.g. dissolution seams, mineral growth in pressure shadows), serpentinite crack-seal veins and polished fault slip surfaces from a serpentinite-bearing mélange in New Zealand. The microstructural information provided by these techniques has yielded new insights into coseismic dehydration and amorphization processes and the interplay between creep and localised rupture in serpentinite shear zones.

  7. Comprehensive analysis of TEM methods for LiFePO4/FePO4 phase mapping: spectroscopic techniques (EFTEM, STEM-EELS) and STEM diffraction techniques (ACOM-TEM).

    Science.gov (United States)

    Mu, X; Kobler, A; Wang, D; Chakravadhanula, V S K; Schlabach, S; Szabó, D V; Norby, P; Kübel, C

    2016-11-01

    Transmission electron microscopy (TEM) has been used intensively in investigating battery materials, e.g. to obtain phase maps of partially (dis)charged (lithium) iron phosphate (LFP/FP), which is one of the most promising cathode material for next generation lithium ion (Li-ion) batteries. Due to the weak interaction between Li atoms and fast electrons, mapping of the Li distribution is not straightforward. In this work, we revisited the issue of TEM measurements of Li distribution maps for LFP/FP. Different TEM techniques, including spectroscopic techniques (energy filtered (EF)TEM in the energy range from low-loss to core-loss) and a STEM diffraction technique (automated crystal orientation mapping (ACOM)), were applied to map the lithiation of the same location in the same sample. This enabled a direct comparison of the results. The maps obtained by all methods showed excellent agreement with each other. Because of the strong difference in the imaging mechanisms, it proves the reliability of both the spectroscopic and STEM diffraction phase mapping. A comprehensive comparison of all methods is given in terms of information content, dose level, acquisition time and signal quality. The latter three are crucial for the design of in-situ experiments with beam sensitive Li-ion battery materials. Furthermore, we demonstrated the power of STEM diffraction (ACOM-STEM) providing additional crystallographic information, which can be analyzed to gain a deeper understanding of the LFP/FP interface properties such as statistical information on phase boundary orientation and misorientation between domains. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Generation of a microelectron beam by an intense short pulse laser in the TEM(1, 0) + TEM(0, 1) mode in vacuum

    International Nuclear Information System (INIS)

    Miyazaki, Shuji; Kawata, Shigeo; Kong, Qing; Miyauchi, Koichi; Sakai, Kei; Hasumi, Shotaro; Sonobe, Ryo; Kikuchi, Takashi

    2005-01-01

    The generation of a high energy microelectron bunch in vacuum by an intense short pulse laser in the TEM(1, 0) + TEM(0, 1) mode is investigated in this paper numerically and analytically. A focused short pulse laser in the TEM(1, 0) + TEM(0, 1) mode has a confinement effect on electrons in the transverse direction due to the transverse ponderomotive force, and at the same time the electrons are accelerated and compressed longitudinally by a longitudinal electric field. In our three-dimensional particle simulations, the maximum kinetic energy of electrons reaches 455 MeV, the maximum density is 3.87 x 10 10 cm -3 , and the normalized transverse and longitudinal rms emittances of accelerated electrons are of the order of 10 -6 m rad at the following parameter values: a 0 = eE 0 /(m e ω c) = 10 (where a 0 is the dimensionless parameter of the laser amplitude, e and m e are the electron charge and rest mass, respectively, E 0 is the laser amplitude, ω the angular frequency of the laser and c the speed of light in vacuum), a laser wavelength λ = 0.8 μm, laser spot size 20λ, laser pulse length 5λ and initial electron velocity 0.99c. Moreover, the transverse and longitudinal sizes of the compressed electron bunch are about 600λ and 10λ, respectively. In this paper, we also present a scaling law of the maximum electron energy. The estimated results of the maximum electron energy coincide well with the simulation results

  9. Nonlinear entropy transfer in ETG-TEM turbulence via TEM driven zonal flows

    International Nuclear Information System (INIS)

    Asahi, Yuuichi; Tsutsui, Hiroaki; Tsuji-Iio, Shunji; Ishizawa, Akihiro; Sugama, Hideo; Watanabe, Tomohiko

    2015-01-01

    Nonlinear interplay of the electron temperature gradient (ETG) modes and the trapped electron modes (TEMs) was investigated by means of gyrokinetic simulation. Focusing on the situation where both TEMs and ETG modes are linearly unstable, the effects of TEM-driven zonal flows on ETG turbulence were examined by means of entropy transfer analysis. In a statistically steady turbulence where the TEM driven zonal flows are dominant, it turned out that the zonal flows meditate the entropy transfer of the ETG modes from the low to high radial wavenumber regions. The successive entropy transfer broadens the potential fluctuation spectrum in the radial wavenumber direction. In contrast, in the situation where ETG modes are unstable but TEMs are stable, the pure ETG turbulence does not produce strong zonal flows, leading to a rather narrow spectrum in the radial wavenumber space and a higher transport level. (author)

  10. Exploration of shallow subsurface resistivity structure using a portable TEM system: TEM-FAST prosystem; Kan`igata TEM ho sochi TEM-FAST prosystem ni yoru senbu hiteiko chosa

    Energy Technology Data Exchange (ETDEWEB)

    Miura, Y; Kumekawa, Y; Takasugi, S [GERD Geothermal Energy Research and Development Co. Ltd., Tokyo (Japan)

    1997-05-27

    Discussions were given on effectiveness of the TEM-FAST ProSystem which is a portable TEM system developed recently for use in exploration of shallow subsurface resistivity. The system consists of a loop type antenna, the TEM-FAST as the main equipment, and a host computer, the host computer controlling the entire system. The system acquires transient response data in secondary induced magnetic fields lasting 4 {mu} sec to 1 m sec. The number of data is 5490 stacks in one measurement, and the data acquisition time is about three minutes. Measurements were carried out by using the TEM-FAST in the vicinity of a well, whose results were compared with those of electric logging, and discussions were given on them. Although the electric logging results had no data available for depths shallower than 35 m, the measurement results from the TEM-FAST were found highly harmonious with those of the electric logging. In addition, there were transmission and telephone lines in locations about 10 m away from the well during the measurement, but extremely high data quality was discovered. 6 refs., 7 figs., 1 tab.

  11. GISAXS modelling of helium-induced nano-bubble formation in tungsten and comparison with TEM

    Science.gov (United States)

    Thompson, Matt; Sakamoto, Ryuichi; Bernard, Elodie; Kirby, Nigel; Kluth, Patrick; Riley, Daniel; Corr, Cormac

    2016-05-01

    Grazing-incidence small angle x-ray scattering (GISAXS) is a powerful non-destructive technique for the measurement of nano-bubble formation in tungsten under helium plasma exposure. Here, we present a comparative study between transmission electron microscopy (TEM) and GISAXS measurements of nano-bubble formation in tungsten exposed to helium plasma in the Large Helical Device (LHD) fusion experiment. Both techniques are in excellent agreement, suggesting that nano-bubbles range from spheroidal to ellipsoidal, displaying exponential diameter distributions with mean diameters μ=0.68 ± 0.04 nm and μ=0.6 ± 0.1 nm measured by TEM and GISAXS respectively. Depth distributions were also computed, with calculated exponential depth distributions with mean depths of 8.4 ± 0.5 nm and 9.1 ± 0.4 nm for TEM and GISAXS. In GISAXS modelling, spheroidal particles were fitted with an aspect ratio ε=0.7 ± 0.1. The GISAXS model used is described in detail.

  12. Is the TEM obsolescent?

    International Nuclear Information System (INIS)

    Williams, D.B.

    2002-01-01

    Full text: The TEM has undergone many revolutions since its invention 70 years ago, but is now a very mature instrument. The major functions of imaging, diffraction and analysis were invented decades ago. Much of the instrument development in the last 20 years has come in peripheral improvements such as ease of operation and computer control which, nevertheless, have made no substantial differences to basic operational methods. The TEM remains a predominantly manual instrument, still providing analog viewing and recording, well into the digital age. Indeed any operator of a Siemens Elmiskop 1 TEM from the 1950s would be more than skilled enough to operate a modern FEG TEM, with little more than a few minutes of training. It is arguable that no other cutting-edge scientific instrument is so basically unchanged in its method of operation over the last five decades, as the TEM. This state of affairs is a recipe for obsolescence. Students today are not interested in mastering the complexities of balancing potentiometers (which are still necessary for good centered dark-field operation) or manipulating sets of tilt controls to move from to , while fighting to maintain eucentricity and a recognizable image on the screen at 200 kX. Students are already masters of the mouse, keyboard or joystick and expect information to be generated, stored, processed and analyzed rapidly and efficiently under full computer control. We need to provide today's students with an instrument to challenge their skills, not those of their parents. There is nothing preventing the creation of a TEM that is under full computer control, except perhaps the notion that the TEM is an instrument worthy of mastery per se, rather than being simply a tool for the characterization of materials. In contrast, the SEM has never been seen as a 'real' electron microscope and consequently has found its way into many more research, education and commercial operations than the TEM. The SEM has also evolved

  13. Observation of Pt-{100}-p(2×2-O reconstruction by an environmental TEM

    Directory of Open Access Journals (Sweden)

    Hengbo Li

    2016-06-01

    Full Text Available The surface structure of noble metal nanoparticles usually plays a crucial role during the catalytic process in the fields of energy and environment. It has been studied extensively by surface analytic methods, such as scanning tunneling microscopy. However, it is still challenging to secure a direct observation of the structural evolution of surfaces of nanocatalysts in reaction (gas and heating conditions at the atomic scale. Here we report an in-situ observation of atomic reconstruction on Pt {100} surfaces exposed to oxygen in an environmental transmission electron microscope (TEM. Our high-resolution TEM images revealed that Pt-{100}-p(2×2-O reconstruction occurs during the reaction between oxygen atoms and {100} facets. A reconstruction model was proposed, and TEM images simulated according to this model with different defocus values match the experimental results well.

  14. Analytical predictions of SGEMP response and comparisons with computer calculations

    International Nuclear Information System (INIS)

    de Plomb, E.P.

    1976-01-01

    An analytical formulation for the prediction of SGEMP surface current response is presented. Only two independent dimensionless parameters are required to predict the peak magnitude and rise time of SGEMP induced surface currents. The analysis applies to limited (high fluence) emission as well as unlimited (low fluence) emission. Cause-effect relationships for SGEMP response are treated quantitatively, and yield simple power law dependencies between several physical variables. Analytical predictions for a large matrix of SGEMP cases are compared with an array of about thirty-five computer solutions of similar SGEMP problems, which were collected from three independent research groups. The theoretical solutions generally agree with the computer solutions as well as the computer solutions agree with one another. Such comparisons typically show variations less than a ''factor of two.''

  15. Analytical quality control of neutron activation analysis by interlaboratory comparison and proficiency test

    International Nuclear Information System (INIS)

    Kim, S. H.; Moon, J. H.; Jeong, Y. S.

    2002-01-01

    Two air filters (V-50, P-50) artificially loaded with urban dust were provided from IAEA and trace elements to study inter-laboratory comparison and proficiency test were determined using instrumental neutron activation analysis non-destructively. Standard reference material(Urban Particulate Matter, NIST SRM 1648) of National Institute of Standard and Technology was used for internal analytical quality control. About 20 elements in each loaded filter sample were determined, respectively. Our analytical data were compared with statistical results using neutron activation analysis, particle induced X-ray emission spectrometry, inductively coupled plasma mass spectroscopy, etc., which were collected from 49 laboratories of 40 countries. From the results that were statistically re-treated with reported values, Z-scores of our analytical values are within ±2. In addition, the results of proficiency test are passed and accuracy and precision of the analytical values are reliable. Consequently, it was proved that analytical quality control for the analysis of air dust samples is reasonable

  16. TEMS: an alternative method for the repair of benign recto-vaginal fistulae.

    Science.gov (United States)

    Darwood, R J; Borley, N R

    2008-07-01

    The repair of high recto-vaginal fistula can be challenging since access may be limited via the endo-anal approach yet the alternative trans-abdominal route carries significant morbidity. We report the use of TEMS to repair a recto-vaginal fistula following anterior resection and pelvic radiotherapy. The patient was placed prone and a 25 cm rectoscope was inserted. A proximally based mucosal advancement flap was raised to repair the fistula. The patient was discharged 2 days later and a contrast study confirmed closure of the fistula. COMPARISON WITH OTHER TECHNIQUES: TEMS allows excellent visualisation of a rectovaginal fistula compared to standard endo-anal or trans-vaginal techniques. The morbidity is lower than the trans-abdominal route. TEMS is a useful technique for the repair of benign recto-vaginal fistula and has distinct advantages over conventional techniques.

  17. Benchmark Comparison of Cloud Analytics Methods Applied to Earth Observations

    Science.gov (United States)

    Lynnes, Chris; Little, Mike; Huang, Thomas; Jacob, Joseph; Yang, Phil; Kuo, Kwo-Sen

    2016-01-01

    Cloud computing has the potential to bring high performance computing capabilities to the average science researcher. However, in order to take full advantage of cloud capabilities, the science data used in the analysis must often be reorganized. This typically involves sharding the data across multiple nodes to enable relatively fine-grained parallelism. This can be either via cloud-based file systems or cloud-enabled databases such as Cassandra, Rasdaman or SciDB. Since storing an extra copy of data leads to increased cost and data management complexity, NASA is interested in determining the benefits and costs of various cloud analytics methods for real Earth Observation cases. Accordingly, NASA's Earth Science Technology Office and Earth Science Data and Information Systems project have teamed with cloud analytics practitioners to run a benchmark comparison on cloud analytics methods using the same input data and analysis algorithms. We have particularly looked at analysis algorithms that work over long time series, because these are particularly intractable for many Earth Observation datasets which typically store data with one or just a few time steps per file. This post will present side-by-side cost and performance results for several common Earth observation analysis operations.

  18. Benchmark Comparison of Cloud Analytics Methods Applied to Earth Observations

    Science.gov (United States)

    Lynnes, C.; Little, M. M.; Huang, T.; Jacob, J. C.; Yang, C. P.; Kuo, K. S.

    2016-12-01

    Cloud computing has the potential to bring high performance computing capabilities to the average science researcher. However, in order to take full advantage of cloud capabilities, the science data used in the analysis must often be reorganized. This typically involves sharding the data across multiple nodes to enable relatively fine-grained parallelism. This can be either via cloud-based filesystems or cloud-enabled databases such as Cassandra, Rasdaman or SciDB. Since storing an extra copy of data leads to increased cost and data management complexity, NASA is interested in determining the benefits and costs of various cloud analytics methods for real Earth Observation cases. Accordingly, NASA's Earth Science Technology Office and Earth Science Data and Information Systems project have teamed with cloud analytics practitioners to run a benchmark comparison on cloud analytics methods using the same input data and analysis algorithms. We have particularly looked at analysis algorithms that work over long time series, because these are particularly intractable for many Earth Observation datasets which typically store data with one or just a few time steps per file. This post will present side-by-side cost and performance results for several common Earth observation analysis operations.

  19. Circular orbits of corotating binary black holes: Comparison between analytical and numerical results

    International Nuclear Information System (INIS)

    Damour, Thibault; Gourgoulhon, Eric; Grandclement, Philippe

    2002-01-01

    We compare recent numerical results, obtained within a 'helical Killing vector' approach, on circular orbits of corotating binary black holes to the analytical predictions made by the effective one-body (EOB) method (which has been recently extended to the case of spinning bodies). On the scale of the differences between the results obtained by different numerical methods, we find good agreement between numerical data and analytical predictions for several invariant functions describing the dynamical properties of circular orbits. This agreement is robust against the post-Newtonian accuracy used for the analytical estimates, as well as under choices of the resummation method for the EOB 'effective potential', and gets better as one uses a higher post-Newtonian accuracy. These findings open the way to a significant 'merging' of analytical and numerical methods, i.e. to matching an EOB-based analytical description of the (early and late) inspiral, up to the beginning of the plunge, to a numerical description of the plunge and merger. We illustrate also the 'flexibility' of the EOB approach, i.e. the possibility of determining some 'best fit' values for the analytical parameters by comparison with numerical data

  20. In Situ TEM Electrical Measurements

    DEFF Research Database (Denmark)

    Canepa, Silvia; Alam, Sardar Bilal; Ngo, Duc-The

    2016-01-01

    understanding of complex physical and chemical interactions in the pursuit to optimize nanostructure function and device performance. Recent developments of sample holder technology for TEM have enabled a new field of research in the study of functional nanomaterials and devices via electrical stimulation...... influence the sample by external stimuli, e.g. through electrical connections, the TEM becomes a powerful laboratory for performing quantitative real time in situ experiments. Such TEM setups enable the characterization of nanostructures and nanodevices under working conditions, thereby providing a deeper...... and measurement of the specimen. Recognizing the benefits of electrical measurements for in situ TEM, many research groups have focused their effort in this field and some of these methods have transferred to ETEM. This chapter will describe recent advances in the in situ TEM investigation of nanostructured...

  1. "One-sample concept" micro-combinatory for high throughput TEM of binary films.

    Science.gov (United States)

    Sáfrán, György

    2018-04-01

    Phases of thin films may remarkably differ from that of bulk. Unlike to the comprehensive data files of Binary Phase Diagrams [1] available for bulk, complete phase maps for thin binary layers do not exist. This is due to both the diverse metastable, non-equilibrium or instable phases feasible in thin films and the required volume of characterization work with analytical techniques like TEM, SAED and EDS. The aim of the present work was to develop a method that remarkably facilitates the TEM study of the diverse binary phases of thin films, or the creation of phase maps. A micro-combinatorial method was worked out that enables both preparation and study of a gradient two-component film within a single TEM specimen. For a demonstration of the technique thin Mn x Al 1- x binary samples with evolving concentration from x = 0 to x = 1 have been prepared so that the transition from pure Mn to pure Al covers a 1.5 mm long track within the 3 mm diameter TEM grid. The proposed method enables the preparation and study of thin combinatorial samples including all feasible phases as a function of composition or other deposition parameters. Contrary to known "combinatorial chemistry", in which a series of different samples are deposited in one run, and investigated, one at a time, the present micro-combinatorial method produces a single specimen condensing a complete library of a binary system that can be studied, efficiently, within a single TEM session. That provides extremely high throughput for TEM characterization of composition-dependent phases, exploration of new materials, or the construction of phase diagrams of binary films. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Comparison between measured and predicted turbulence frequency spectra in ITG and TEM regimes

    NARCIS (Netherlands)

    Citrin, J.; Arnichand, H.; Bernardo, J.; Bourdelle, C.; Garbet, X.; Jenko, F.; Hacquin, S.; Puschel, M. J.; Sabot, R.

    2017-01-01

    The observation of distinct peaks in tokamak core reflectometry measurements—named quasi-coherent-modes (QCMs)—are identified as a signature of trapped-electron-mode (TEM) turbulence (Arnichand et al 2016 Plasma Phys. Control. Fusion 58 014037). This phenomenon is investigated with detailed linear

  3. An interactive website for analytical method comparison and bias estimation.

    Science.gov (United States)

    Bahar, Burak; Tuncel, Ayse F; Holmes, Earle W; Holmes, Daniel T

    2017-12-01

    Regulatory standards mandate laboratories to perform studies to ensure accuracy and reliability of their test results. Method comparison and bias estimation are important components of these studies. We developed an interactive website for evaluating the relative performance of two analytical methods using R programming language tools. The website can be accessed at https://bahar.shinyapps.io/method_compare/. The site has an easy-to-use interface that allows both copy-pasting and manual entry of data. It also allows selection of a regression model and creation of regression and difference plots. Available regression models include Ordinary Least Squares, Weighted-Ordinary Least Squares, Deming, Weighted-Deming, Passing-Bablok and Passing-Bablok for large datasets. The server processes the data and generates downloadable reports in PDF or HTML format. Our website provides clinical laboratories a practical way to assess the relative performance of two analytical methods. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Comparison of three analytical methods for the determination of trace elements in whole blood

    International Nuclear Information System (INIS)

    Ward, N.I.; Stephens, R.; Ryan, D.E.

    1979-01-01

    Three different analytical techniques were compared in a study of the role of trace elements in multiple sclerosis. Data for eight elements (Cd, Co, Cr, Cu, Mg, Mn, Pb, Zn) from neutron activation, flame atomic absorption and electrothermal atomic absorption methods were compared and evaluated statistically. No difference (probability less than 0.001) was observed in the elemental values obtained. Comparison of data between suitably different analytical methods gives increased confidence in the results obtained and is of particular value when standard reference materials are not available. (Auth.)

  5. Global gyrokinetic simulations of TEM microturbulence

    Science.gov (United States)

    Vernay, T.; Brunner, S.; Villard, L.; McMillan, B. F.; Jolliet, S.; Bottino, A.; Görler, T.; Jenko, F.

    2013-07-01

    Global gyrokinetic simulations of electrostatic temperature-gradient-driven trapped-electron-mode (TEM) turbulence using the δf particle-in-cell code ORB5 are presented. The electron response is either fully kinetic or hybrid, i.e. considering kinetic trapped and adiabatic passing electrons. A linear benchmark in the TEM regime against the Eulerian-based code GENE is presented. Two different methods for controlling the numerical noise, based, respectively, on a Krook operator and a so-called coarse-graining approach, are discussed and successfully compared. Both linear and non-linear studies are carried out for addressing the issue of finite-ρ*-effects and finite electron collisionality on TEM turbulence. Electron collisions are found to damp TEMs through the detrapping process, while finite-ρ*-effects turn out to be important in the non-linear regime but very small in the linear regime. Finally, the effects of zonal flows on TEM turbulence are briefly considered as well and shown to be unimportant in the temperature-gradient-driven TEM regime. Consistently, basically no difference is found between linear and non-linear critical electron temperature gradients in the TEM regime.

  6. Neutron, x-ray scattering and TEM studies of Ni-Ti multilayers

    International Nuclear Information System (INIS)

    Keem, J.E.; Wood, J.; Grupido, N.; Hart, K.; Nutt, S.; Reichel, D.G.; Yelon, W.B.

    1988-01-01

    The authors present an analysis of Ni-Ti multilayer neutron reflectors and supermirrors undertaken to identify the causes of the lower than expected observed scattering power and critical angle enhancement of Ni-Ti supermirrors. Results of these investigations focus attention on cusp formation in the Ni-Ti bilayers as probable cause for the reduced neutron scattering power. Grazing angle x-ray and neutron scattering, wide angle neutron diffraction and analytical cross sectional TEM have been used. The multilayers were produced by magnetron sputtering and ion-beam deposition on float glass substrates and silicon wafers

  7. A comparison of two analytical evaluation methods for educational computer games for young children

    NARCIS (Netherlands)

    Bekker, M.M.; Baauw, E.; Barendregt, W.

    2008-01-01

    In this paper we describe a comparison of two analytical methods for educational computer games for young children. The methods compared in the study are the Structured Expert Evaluation Method (SEEM) and the Combined Heuristic Evaluation (HE) (based on a combination of Nielsen’s HE and the

  8. TEM heat transport and fluctuations in the HSX stellarator: experiments and comparison with gyrokinetic simulation

    Science.gov (United States)

    Smoniewski, J.; Faber, B. J.; Sánchez, E.; Calvo, I.; Pueschel, M. J.; Likin, K. M.; Deng, C. B.; Talmadge, J. N.

    2017-10-01

    The Helically Symmetric eXperiment (HSX) has demonstrated reduced neoclassical transport in the plasma core with quasi-symmetry [Lore Thesis 2010], while outside this region the electron thermal diffusivity is well above the neoclassical level, likely due to the Trapped Electron Mode (TEM) [Weir PoP 2015, Faber PoP 2015]. We compare gyrokinetic simulations of the TEM to experimental heat flux and density fluctuation measurements for two configurations: Quasi-Helical Symmetry (QHS) and broken symmetry (Mirror). Both experiment and simulation show that the heat flux for Mirror is larger than for QHS by about a factor of two. Initial interferometer measurements provide evidence that density-gradient-driven TEMs are driving turbulence. Calculations of the collisionless damping of zonal flows provide another perspective into the difference between geometries. Similar to other stellarators [Monreal PPCF 2016], the zonal flow residual goes to zero at long wavelengths in both configurations. Additionally, the very short time decay of the zonal flow due to neoclassical polarization is constant between configurations. However, the collisionless damping time is longer and the zonal flow oscillation frequency is smaller in QHS than Mirror, consistent with reduced radial particle drifts. Work supported by the US DOE under Grant DE-FG02-93ER54222.

  9. MT3FT-15OR0204122: Report on the acquisition and installation of FEI Talos F200X S/TEM

    Energy Technology Data Exchange (ETDEWEB)

    Parish, Chad M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-09-01

    This document describes the installation, performance, and early results from the FCRD-funded acquisition of a new advanced analytical scanning / transmission electron microscopy (S/TEM) at the Oak Ridge National Laboratory Low Activation Materials Development and Analysis (LAMDA) facility.

  10. Accelerator-tem interface facility and application

    International Nuclear Information System (INIS)

    Li Ming; He Jun; Yang Zheng; Zhou Lin; Liu Chuansheng; Guo Liping; Jiang Changzhong; Yang Shibo; Fu Dejun; Fan Xiangjun; Liu Jiarui; Lee, J.C.

    2010-01-01

    An accelerator-TEM interface facility has been established at Wuhan University. The system consists of an H800 TEM linked to a 200 kV ion implanter and a 2 x 1.7 MV tandetron accelerator. Measures were taken to isolate the TEM from mechanical vibration transmitted from the ion beam lines and good resolution was maintained with the TEM machine when operated under high zoom modes during the ion implantation. Nitrogen ions at 115 keV were successfully transported from the implanter into the TEM chamber through the interface system, and the ion currents measured at the entrance of the TEM column were between 20 and 180 nA. Structural evolution caused by ion irradiation in Si, GaAs, nanocrystal Ag were observed in situ. The TEM sample could be tilted by 52 degree and for low energy ion irradiation, real time observation was realized. The in situ observation showed that the critical implant dose for amorphization of Si is 2 x 10 14 cm -2 and it became fully amorphized at 3 x 10 15 cm -2 . Amorphization of GaAs started at 1 x 10 14 cm -2 , whereas for nanocrystal Ag, the starting dose was 6 x 10 14 cm -2 . The nuclear material C276 samples implanted with 115 keV Ar+ was also studied and dislocation loops with sizes of 3-12 nm were clearly observed after implantation to doses higher than 1 x 10 15 cm -2 . The density of the loops increased with the increase in the implant dose and evolution to polycrystalline and amorphous structures were observed at 5 x 10 15 cm -2 and 3 x 10 16 cm -2 , respectively. An in situ RBS/C chamber has been installed on the transport line of the accelerator-TEM interface system. This makes it possible to in situ measure composition and location of impurities in the lattice of the implanted samples. In addition, a 50 kV low-energy gaseous ion generator was installed close to the TEM chamber, which facilitates in situ TEM observation of helium bubbles formed in materials by helium implantation. (authors)

  11. Recent advances in FIB-TEM specimen preparation techniques

    International Nuclear Information System (INIS)

    Li Jian; Malis, T.; Dionne, S.

    2006-01-01

    Preparing high-quality transmission electron microscopy (TEM) specimens is of paramount importance in TEM studies. The development of the focused ion beam (FIB) microscope has greatly enhanced TEM specimen preparation capabilities. In recent years, various FIB-TEM foil preparation techniques have been developed. However, the currently available techniques fail to produce TEM specimens from fragile and ultra-fine specimens such as fine fibers. In this paper, the conventional FIB-TEM specimen preparation techniques are reviewed, and their advantages and shortcomings are compared. In addition, a new technique suitable to prepare TEM samples from ultra-fine specimens is demonstrated

  12. TEM analysis of a friction stir-welded butt joint of Al-Si-Mg alloys

    International Nuclear Information System (INIS)

    Cabibbo, M.; Meccia, E.; Evangelista, E.

    2003-01-01

    The microstructure evolution of a joint of Al-Si-Mg alloys A6056-T4 and A6056-T6 has been characterized by transmission electron microscopy (TEM). Metallurgical investigations, hardness and mechanical tests were also performed to correlate the TEM investigations to the mechanical properties of the produced friction stir-welded butt joint. After friction stir-welding thermal treatment has been carried out at 530 deg. C followed by ageing at 160 deg. C (T6). The base material (T4) and the heat-treated one (T6) were put in comparison showing a remarkable ductility reduction of the joint after T6 treatment

  13. TEMS: results of a specialist centre.

    Science.gov (United States)

    Flexer, S M; Durham-Hall, A C; Steward, M A; Robinson, J M

    2014-06-01

    Transanal endoscopic microsurgery (TEMS) is becoming more widespread due to the increasing body of evidence to support its role. Previous published data has reported recurrence rates in excess of 10% for benign polyps after TEMS. Bradford Royal Infirmary is a tertiary referral centre for TEMS and early rectal cancer in the UK. Data for all TEMS operations were entered into a prospective database over a 7-year period. Demographic data, complications and recurrence rates were recorded. Both benign adenomas and malignant lesions were included. A total of 164 patients (65% male), with a mean age of 68 years were included; 114 (70%) of the lesions resected were benign adenomas, and 50 (30%) were malignant lesions. Median polyp size was 4 (range 0.6-14.5) cm. Mean length of operation was 55 (range 10-120) min. There were no recurrences in any patients with a benign adenoma resected; two patients with malignant lesions developed recurrences. Three intra-operative complications were recorded, two rectal perforations (repaired primarily, one requiring defunctioning stoma), and a further patient suffered a blood loss of >300 ml requiring transfusion. Six patients developed strictures requiring dilation either endoscopically or under anaesthetic in the post-operative period. We have demonstrated that TEMS procedures performed in a specialist centre provide low rates of both recurrence and complication. Within a specialist centre, TEMS surgery should be offered to all patients for rectal lesions, both benign and malignant, that are amenable to TEMS.

  14. Accelerator-TEM interface facility and application

    International Nuclear Information System (INIS)

    Liu Chuansheng; Li Ming; He Jun; Yang Zheng; Zhou Lin; Wang Zesong; Guo Liping; Jiang Changzhong; Yang Shibo; Fu Dejun; Fan Xiangjun; Liu Jiarui; Lee J C

    2010-01-01

    An accelerator-TEM interface facility has been established at Wuhan University in 2008. The system consists of an H800 TEM linked to a 200 kV ion implanter and a 2 x 1.7 MV tandem accelerator. Nitrogen ions at 115 keV were successfully transported from the implanter into the TEM chamber through the interface system, and the ion currents measured at the entrance of the TEM column were between 20 and 180 nA. Structural evolution caused by ion irradiation in Si, GaAs, nanocrystal Ag was observed in situ. The in situ observation showed that the critical implantation dose for amorphization of Si is 10 14 cm -2 . The nuclear material C276 samples implanted with 115 keV Ar + was also studied, and dislocation loops sized at 3-12 nm were clearly observed after implantation to doses of over 1 x 10 15 cm -2 . The density of the loops increased with the dose. Evolution to polycrystalline and amorphous structures were observed at 5 x l0 15 cm -2 and 3 x 10 16 cm -2 , respectively. An in situ RBS/C chamber was installed on the transport line of the accelerator-TEM interface system. This enables in situ measurement of composition and location of the implanted species in lattice of the samples. In addition, a 50 kV low-energy gaseous ion generator was installed close to the TEM chamber, which facilitates in situ TEM observation of helium bubbles formed in helium-implanted materials. (authors)

  15. TEM study of internal oxidation in an ODS-Eurofer alloy

    International Nuclear Information System (INIS)

    Klimenkov, M.; Lindau, R.; Moeslang, A.

    2009-01-01

    Analytical TEM investigations of samples from an oxide dispersion-strengthened Eurofer batch show the formation of new type of precipitates of Fe-Cr-V-O composition and a size of 40-250 nm. Structural HRTEM analysis reveals that the precipitates consist of (Mn,Fe)(Cr,V) 2 O 4 manganese chromium oxide of spinel structure. In some cases, the inclusions order along lines that can reach more than ten micrometers in length. Such lines of large particles might have a negative influence on the mechanical properties of the steel, as was observed. It is assumed that they form by internal oxidation during hot isostatic pressing due to the high oxygen content of the mechanically alloyed powder.

  16. Interlanguage comparison of sport discourse (on the material of sport analytic article

    Directory of Open Access Journals (Sweden)

    Gavryushina Ekaterina Alexandrovna

    2016-06-01

    Full Text Available The article is devoted to the study of cultural and mental specificity of language units in the sport communication. The study was conducted on the material of English, Russian and German analytical articles, thematically related to tennis. Using the technique of cross-language comparison it is revealed significant characteristic parameters of sports discourse. The proposed comparative procedure consists in three stages of analysis: linguistic, cognitive-communicative and linguistic-cultural. During the analysis at each step there were identified certain criteria specific to the sport discourse in three linguasocieties. Sport communication reflects not only the specificity and originality of the language, but also the traditions, history, mentality, culture, and behavior patterns of modern professional sport community. Comparative study of sport discourse reveals the cultural, linguistic and cognitive features of sublanguage sports and allows to get a common view of the structure of sport analytical articles.

  17. Kernel method for air quality modelling. II. Comparison with analytic solutions

    Energy Technology Data Exchange (ETDEWEB)

    Lorimer, G S; Ross, D G

    1986-01-01

    The performance of Lorimer's (1986) kernel method for solving the advection-diffusion equation is tested for instantaneous and continuous emissions into a variety of model atmospheres. Analytical solutions are available for comparison in each case. The results indicate that a modest minicomputer is quite adequate for obtaining satisfactory precision even for the most trying test performed here, which involves a diffusivity tensor and wind speed which are nonlinear functions of the height above ground. Simulations of the same cases by the particle-in-cell technique are found to provide substantially lower accuracy even when use is made of greater computer resources.

  18. Comparison of ultramicrotomy and focused-ion-beam for the preparation of TEM and STEM cross section of organic solar cells

    DEFF Research Database (Denmark)

    Corazza, Michael; Simonsen, Søren Bredmose; Gnaegi, Helmut

    2016-01-01

    The challenge of preparing cross sections of organic photovoltaics (OPV) suitable for transmission electron microscopy (TEM) and scanning TEM (STEM) is addressed. The samples were polymer solar cells fabricated using roll-to-roll (R2R) processing methods on a flexible polyethylene terephthalate...... resolution, enabling further studies of phase separation of P3HT:PCBM by means of energy filtered TEM (EFTEM). The sample prepared by FIB shows good structure preservation, but reduced resolution due to non-optimal thicknesses achieved after treatment. Degradation studies of samples prepared...

  19. Soft nanomaterials analysed by in situ liquid TEM: Towards high resolution characterisation of nanoparticles in motion

    Directory of Open Access Journals (Sweden)

    Joseph P. Patterson

    2015-12-01

    Full Text Available In this article we present in situ transmission electron microscopy (TEM of soft, synthetic nanoparticles with a comparative analysis using conventional TEM methods. This comparison is made with the simple aim of describing what is an unprecedented example of in situ imaging by TEM. However, we contend the technique will quickly become essential in the characterisation of analogous systems, especially where dynamics are of interest in the solvated state. In this case, particles were studied which were obtained from the direct polymerisation of an oxaliplatin analogue, designed for an ongoing programme in novel chemotherapeutic delivery systems. The resulting nanoparticles provided sufficient contrast for facile imaging in situ, and point towards key design parameters that enable this new characterisation approach for organic nanomaterials. We describe the preparation of the synthetic nanoparticles together with their characterisation in liquid water. Finally, we provide a future perspective of this technique for the analysis of soft and dynamic nanomaterials and discussion the progress which needs to be made in order to bring in situ liquid TEM to its full potential.

  20. Comparison of analytical parameters of beer brewed in two different technological ways at two pub breweries

    Directory of Open Access Journals (Sweden)

    Pavel Kryl

    2012-01-01

    Full Text Available This publication deals with brewing beer by infusion and decoction technologies of mash production in microbreweries. Samples of two microbrewery beers are compared, namely Richard beer (Brno-Žebětín produced in a double mash manner appropriate for the Czech brewing type, and beer samples taken at the laboratory microbrewery of Mendel University in Brno (MENDELU, where beer is produced in a simpler and less energy – demanding infusion method. At all the beer samples the basic analytical parameters of real extract, ethanol content, degree of fermentation and the extract of original hopped wort were measured using an automatic beer analyzer. The results coming out of the automatic beer analyzer are compared with the results of the beer samples analysis performed by liquid chromatography, by which the contents of oligosaccharides, maltose, glycerol and ethanol were measured. Both methods provide a number of analytical results for the comparison of decoction and infusion techniques, and analytical characteristics of both the brewing procedures. Emphasis is placed on statistical data processing and comparison of different types of beer and particular brews between each other, both in terms of production technology as well as beer sampling throughout the year.

  1. Quantitative Comparison of Ternary Eutectic Phase-Field Simulations with Analytical 3D Jackson-Hunt Approaches

    Science.gov (United States)

    Steinmetz, Philipp; Kellner, Michael; Hötzer, Johannes; Nestler, Britta

    2018-02-01

    For the analytical description of the relationship between undercoolings, lamellar spacings and growth velocities during the directional solidification of ternary eutectics in 2D and 3D, different extensions based on the theory of Jackson and Hunt are reported in the literature. Besides analytical approaches, the phase-field method has been established to study the spatially complex microstructure evolution during the solidification of eutectic alloys. The understanding of the fundamental mechanisms controlling the morphology development in multiphase, multicomponent systems is of high interest. For this purpose, a comparison is made between the analytical extensions and three-dimensional phase-field simulations of directional solidification in an ideal ternary eutectic system. Based on the observed accordance in two-dimensional validation cases, the experimentally reported, inherently three-dimensional chain-like pattern is investigated in extensive simulation studies. The results are quantitatively compared with the analytical results reported in the literature, and with a newly derived approach which uses equal undercoolings. A good accordance of the undercooling-spacing characteristics between simulations and the analytical Jackson-Hunt apporaches are found. The results show that the applied phase-field model, which is based on the Grand potential approach, is able to describe the analytically predicted relationship between the undercooling and the lamellar arrangements during the directional solidification of a ternary eutectic system in 3D.

  2. TEM sample preparation by femtosecond laser machining and ion milling for high-rate TEM straining experiments

    Energy Technology Data Exchange (ETDEWEB)

    Voisin, Thomas; Grapes, Michael D. [Dept. of Materials Science and Engineering, Johns Hopkins University, Baltimore, MD 21218 (United States); Zhang, Yong [Dept. of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218 (United States); Lorenzo, Nicholas; Ligda, Jonathan; Schuster, Brian [US Army Research Laboratory, Aberdeen Proving Ground, Aberdeen, MD 21005 (United States); Weihs, Timothy P. [Dept. of Materials Science and Engineering, Johns Hopkins University, Baltimore, MD 21218 (United States)

    2017-04-15

    To model mechanical properties of metals at high strain rates, it is important to visualize and understand their deformation at the nanoscale. Unlike post mortem Transmission Electron Microscopy (TEM), which allows one to analyze defects within samples before or after deformation, in situ TEM is a powerful tool that enables imaging and recording of deformation and the associated defect motion during mechanical loading. Unfortunately, all current in situ TEM mechanical testing techniques are limited to quasi-static strain rates. In this context, we are developing a new test technique that utilizes a rapid straining stage and the Dynamic TEM (DTEM) at the Lawrence Livermore National Laboratory (LLNL). The new straining stage can load samples in tension at strain rates as high as 4×10{sup 3}/s using two piezoelectric actuators operating in bending while the DTEM at LLNL can image in movie mode with a time resolution as short as 70 ns. Given the piezoelectric actuators are limited in force, speed, and displacement, we have developed a method for fabricating TEM samples with small cross-sectional areas to increase the applied stresses and short gage lengths to raise the applied strain rates and to limit the areas of deformation. In this paper, we present our effort to fabricate such samples from bulk materials. The new sample preparation procedure combines femtosecond laser machining and ion milling to obtain 300 µm wide samples with control of both the size and location of the electron transparent area, as well as the gage cross-section and length. - Highlights: • Tensile straining TEM specimens made by femtosecond laser machining and ion milling. • Accurate positioning of the electron transparent area within a controlled gauge region. • Optimization of femtosecond laser and ion milling parameters. • Fast production of numerous samples with a highly repeatable geometry.

  3. TEM of nanostructured metals and alloys

    International Nuclear Information System (INIS)

    Karnthaler, H.P.; Waitz, T.; Rentenberger, C.; Mingler, B.

    2004-01-01

    Nanostructuring has been used to improve the mechanical properties of bulk metals and alloys. Transmission electron microscopy (TEM) including atomic resolution is therefore appropriate to study these nanostructures; four examples are given as follows. (1) The early stages of precipitation at RT were investigated in an Al-Mg-Si alloy. By high resolution TEM it is shown that the precipitates lie on (0 0 1) planes having an ordered structure. (2) In Co alloys the fronts of martensitic phase transformations were analysed showing that the transformation strains are very small thus causing no surface relief. (3) Re-ordering and recrystallization were studied by in situ TEM of an Ni 3 Al alloy being nanocrystalline after severe plastic deformation. (4) In NiTi severe plastic deformation is leading to the formation of amorphous shear bands. From the TEM analysis it is concluded that the amorphization is caused by plastic shear instability starting in the shear bands

  4. Processing grounded-wire TEM signal in time-frequency-pseudo-seismic domain: A new paradigm

    Science.gov (United States)

    Khan, M. Y.; Xue, G. Q.; Chen, W.; Huasen, Z.

    2017-12-01

    Grounded-wire TEM has received great attention in mineral, hydrocarbon and hydrogeological investigations for the last several years. Conventionally, TEM soundings have been presented as apparent resistivity curves as function of time. With development of sophisticated computational algorithms, it became possible to extract more realistic geoelectric information by applying inversion programs to 1-D & 3-D problems. Here, we analyze grounded-wire TEM data by carrying out analysis in time, frequency and pseudo-seismic domain supported by borehole information. At first, H, K, A & Q type geoelectric models are processed using a proven inversion program (1-D Occam inversion). Second, time-to-frequency transformation is conducted from TEM ρa(t) curves to magneto telluric MT ρa(f) curves for the same models based on all-time apparent resistivity curves. Third, 1-D Bostick's algorithm was applied to the transformed resistivity. Finally, EM diffusion field is transformed into propagating wave field obeying the standard wave equation using wavelet transformation technique and constructed pseudo-seismic section. The transformed seismic-like wave indicates that some reflection and refraction phenomena appear when the EM wave field interacts with geoelectric interface at different depth intervals due to contrast in resistivity. The resolution of the transformed TEM data is significantly improved in comparison to apparent resistivity plots. A case study illustrates the successful hydrogeophysical application of proposed approach in recovering water-filled mined-out area in a coal field located in Ye county, Henan province, China. The results support the introduction of pseudo-seismic imaging technology in short-offset version of TEM which can also be an useful aid if integrated with seismic reflection technique to explore possibilities for high resolution EM imaging in future.

  5. SAXS and TEM Investigation of Bentonite Structure

    International Nuclear Information System (INIS)

    Matusewicz, Michal; Liljestroem, Ville; Muurinen, Arto; Serimaa, Ritva

    2013-01-01

    A preliminary investigation of bentonite structure using Small-Angle X-ray Scattering (SAXS) and Transmission Electron Microscopy (TEM) is presented. Three types of clay were used: unchanged MX-80 bentonite and purified clays with sodium or calcium ions. Quantitative information in nano-scale - basal spacing, mean crystallite size - was obtained from SAXS, which was complemented by TEM to give qualitative information from micron to nanometre scale. SAXS seems to be a more reliable source of quantitative data than TEM. SAXS gives the averaged information about basal spacing. TEM in this study gives more qualitative information, but in a greater resolution range. The presented work is a starting point to combine more methods to obtain a better idea of bentonite structure. (authors)

  6. Comparison of potential method in analytic hierarchy process for multi-attribute of catering service companies

    Science.gov (United States)

    Mamat, Siti Salwana; Ahmad, Tahir; Awang, Siti Rahmah

    2017-08-01

    Analytic Hierarchy Process (AHP) is a method used in structuring, measuring and synthesizing criteria, in particular ranking of multiple criteria in decision making problems. On the other hand, Potential Method is a ranking procedure in which utilizes preference graph ς (V, A). Two nodes are adjacent if they are compared in a pairwise comparison whereby the assigned arc is oriented towards the more preferred node. In this paper Potential Method is used to solve problem on a catering service selection. The comparison of result by using Potential method is made with Extent Analysis. The Potential Method is found to produce the same rank as Extent Analysis in AHP.

  7. Application of TEM to highly reactive metals

    International Nuclear Information System (INIS)

    Sherry, W.M.; Prinz, F.

    1982-01-01

    In the following a method for the preparation and observation of sodium TEM specimens and the first TEM micrograph ever to be published on the dislocation microstructure of sodium are reported. (orig./IHOE) [de

  8. Mechanical Conversion for High-Throughput TEM Sample Preparation

    International Nuclear Information System (INIS)

    Kendrick, Anthony B; Moore, Thomas M; Zaykova-Feldman, Lyudmila

    2006-01-01

    This paper presents a novel method of direct mechanical conversion from lift-out sample to TEM sample holder. The lift-out sample is prepared in the FIB using the in-situ liftout Total Release TM method. The mechanical conversion is conducted using a mechanical press and one of a variety of TEM coupons, including coupons for both top-side and back-side thinning. The press joins a probe tip point with attached TEM sample to the sample coupon and separates the complete assembly as a 3mm diameter TEM grid, compatible with commercially available TEM sample holder rods. This mechanical conversion process lends itself well to the high through-put requirements of in-line process control and to materials characterization labs where instrument utilization and sample security are critically important

  9. The comparison of available data on PWR assembly thermal behavior with analytical predictions. Topical report (final)

    International Nuclear Information System (INIS)

    Liu, J.; Todreas, N.

    1979-02-01

    The comparison of available data with analytical predictions has been illustrated in this report. Since few data on the cross flow are available, a study of parameters in the transverse momentum equation was performed to assess the sensitivity of results to their assumed values. It is confirmed that effects of these parameters on the overall results are not significant under PWR operating conditions. Data on subchannel properties of quality and mass flux were also assessed. From the data comparisons, it is evident that COBRA can successfully predict the PWR normal operating conditions but cannot predict the trend under bulk quality conditions

  10. TEM-145 and TEM-146 β-lactamases produced by Escherichia coli ...

    African Journals Online (AJOL)

    GREGO

    2007-03-05

    Mar 5, 2007 ... Key words: Escherichia coli, plasmid-mediated, TEM β-lactamase. ... Enterobacteriaceae, the most prevalent mechanism of resistance to ... the production of a relatively inhibitor-resistant OXA-type β-lactamase .... and 8.6 as transcripts of the E. coli chromosomal AmpC .... Mode of action and mechanisms of.

  11. Determination of the initial oxidation behavior of Zircaloy-4 by in-situ TEM

    International Nuclear Information System (INIS)

    Harlow, Wayne; Ghassemi, Hessam; Taheri, Mitra L.

    2016-01-01

    The corrosion behavior of Zircaloy-4 (Zry-4), specifically by oxidation, is a problem of great importance as this material is critical for current nuclear reactor cladding. The early formation behavior and structure of the oxide layer during oxidation was studied using in-situ TEM techniques that allowed for Zry-4 to be monitored during corrosion. These environmental exposure experiments were coupled with precession electron diffraction to identify and quantify the phases present in the samples before and after the oxidation. Following short-term, high temperature oxidation, the dominant phase was revealed to be monoclinic ZrO 2 in a columnar structure. These samples oxidized in-situ contained structures that correlated well with bulk Zry-4 subjected to autoclave treatment, which were used for comparison and validation of this technique. By using in-situ TEM the effect of microstructure features, such as grain boundaries, on oxidation behavior of an alloy can be studied. The technique presented herein holds the potential to be applied any alloy system to study these effects. - Highlights: • In-situ TEM was used to oxidize samples of Zircaloy-4. • Similar behavior was found in the in-situ oxidized and autoclave-oxidized samples. • Precession diffraction was used to characterize oxide phase and texture.

  12. A TEM study of strained SiGe/Si and related heteroepitaxial structures

    International Nuclear Information System (INIS)

    Benedetti, Alessandro

    2002-01-01

    The role of SiGe/Si heterostructures and related materials has become increasingly important within the last few decades. In order to increase the scale of integration, however, devices with active elements not larger than few tens of nanometer have been recently introduced. There is, therefore, a strong need for an analytical technique capable of giving information about submicron-sized components. An investigation on a nanometre scale can be performed by the combination of a fully equipped Transmission Electron Microscope (TEM) with a Field Emission Gun (PEG) electron source, which enables one to use a wide range of analytical techniques with an electron probe as small as 0.5 nm. In this work, two different types of SiGe/Si-based devices were investigated. Strained-Si n-channel MOSFETs. The use of Strained-Si n-channel grown on SiGe should improve both carrier mobility and transconductance with respect to conventional MOSFETs. Materials analysed in this work showed an extremely high transconductance but a rather low mobility. In order to relate their microstructural properties to their electrical performance, as well as to improve the device design, a full quantitative and qualitative structural characterisation was performed. SiGe Multiple Quantum Wells (MQW) IR detectors Light detection is achieved by collecting the photogenerated carriers, injected from the SiGe QWs layers into the Si substrate. A key factor is the Ge profile across a single QW, since it governs the band structure and therefore the device performances. Four different TEM techniques were used to determine the Ge distribution across a single well, showing an overall good agreement among the results. The Ge profiles broadening, consistent with data available in literature, was successfully explained and theoretically predicted by the combined effect of Ge segregation and gas dwell times within the reactor. (author)

  13. 40 keV atomic resolution TEM

    International Nuclear Information System (INIS)

    Bell, David C.; Russo, Christopher J.; Kolmykov, Dmitry V.

    2012-01-01

    Here we present the first atomic resolution TEM imaging at 40 keV using an aberration-corrected, monochromated source TEM. Low-voltage High-Resolution Electron Microscopy (LVHREM) has several advantages, including increased cross-sections for inelastic and elastic scattering, increased contrast per electron and improved spectroscopy efficiency, decreased delocalization effects and reduced knock-on damage. Together, these often improve the contrast to damage ratio obtained on a large class of samples. Third-order aberration correction now allows us to operate the TEM at low energies while retaining atomic resolution, which was previously impossible. At low voltage the major limitation to resolution becomes the chromatic aberration limit. We show that using a source monochromator we are able to reduce the effect of chromatic aberration and achieve a usable high-resolution limit at 40 keV to less than 1 Å. We show various materials' examples of the application of the technique to image graphene and silicon, and compare atomic resolution images with electron multislice simulations. -- Highlights: ► We present the first atomic resolution images recorded at 40 keV using an aberration-corrected, monochromated TEM. ► We show information transfer measured to better than 1 Å. ► At 40 keV an aberration-corrected monochromated TEM is limited by fifth-order spherical aberration. ► We show that using a monochromator the effect of chromatic aberration is reduced to enable high resolution imaging. ► Low voltage high resolution electron microscopy will be beneficial for imaging the organic/inorganic materials interface.

  14. Moessbauer effect and TEM in mineralogy

    International Nuclear Information System (INIS)

    Ferrow, E.A.

    1994-01-01

    Moessbauer effect (ME) provides useful information on oxidation state, co-ordination number, co-ordination state, site occupancies, and magnetic properties of Fe-bearing phases. The information gained by ME together with the information provided by other conventional techniques is used to extract temperature, pressure, and kinetics of rock-forming processes. Nevertheless, ME requires that the phases studied are homogeneous over an extremely large volume and that Fe is a major component of the system. Transmission electron microscopy (TEM), on the other hand, provides similar information over a very small volume for a system of any component. However, present TEM spectrometers do not provide sufficient resolution to detect the mixed oxidation state. A complete characterisation of phases in rocks requires, therefore, that conventional techniques be combined with TEM. (orig.)

  15. Novel sample preparation for operando TEM of catalysts

    International Nuclear Information System (INIS)

    Miller, Benjamin K.; Barker, Trevor M.; Crozier, Peter A.

    2015-01-01

    A new TEM sample preparation method is developed to facilitate operando TEM of gas phase catalysis. A porous Pyrex-fiber pellet TEM sample was produced, allowing a comparatively large amount of catalyst to be loaded into a standard Gatan furnace-type tantalum heating holder. The increased amount of catalyst present inside the environmental TEM allows quantitative determination of the gas phase products of a catalytic reaction performed in-situ at elevated temperatures. The product gas concentration was monitored using both electron energy loss spectroscopy (EELS) and residual gas analysis (RGA). Imaging of catalyst particles dispersed over the pellet at atomic resolution is challenging, due to charging of the insulating glass fibers. To overcome this limitation, a metal grid is placed into the holder in addition to the pellet, allowing catalyst particles dispersed over the grid to be imaged, while particles in the pellet, which are assumed to experience identical conditions, contribute to the overall catalytic conversion inside the environmental TEM cell. The gas within the cell is determined to be well-mixed, making this assumption reasonable. - Highlights: • High in-situ conversion of CO to CO 2 achieved by a novel TEM sample preparation method. • A 3 mm fiber pellet increases the TEM sample surface area by 50×. • Operando atomic resolution is maintained by also including a 3 mm grid in the sample. • Evidence for a well-mixed gas composition inside the ETEM cell is given

  16. TEM sample preparation by FIB for carbon nanotube interconnects

    International Nuclear Information System (INIS)

    Ke, Xiaoxing; Bals, Sara; Romo Negreira, Ainhoa; Hantschel, Thomas; Bender, Hugo; Van Tendeloo, Gustaaf

    2009-01-01

    A powerful method to study carbon nanotubes (CNTs) grown in patterned substrates for potential interconnects applications is transmission electron microscopy (TEM). However, high-quality TEM samples are necessary for such a study. Here, TEM specimen preparation by focused ion beam (FIB) has been used to obtain lamellae of patterned samples containing CNTs grown inside contact holes. A dual-cap Pt protection layer and an extensive 5 kV cleaning procedure are applied in order to preserve the CNTs and avoid deterioration during milling. TEM results show that the inner shell structure of the carbon nanotubes has been preserved, which proves that focused ion beam is a useful technique to prepare TEM samples of CNT interconnects.

  17. TEM sample preparation by FIB for carbon nanotube interconnects

    Energy Technology Data Exchange (ETDEWEB)

    Ke, Xiaoxing, E-mail: xiaoxing.ke@ua.ac.be [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Bals, Sara [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Romo Negreira, Ainhoa [IMEC, Kapeldreef 75, B-3001 Leuven (Belgium); Metallurgy and Materials Engineering Department, KU Leuven, Kasteelpark Arenberg 44, Leuven B-3001 (Belgium); Hantschel, Thomas; Bender, Hugo [IMEC, Kapeldreef 75, B-3001 Leuven (Belgium); Van Tendeloo, Gustaaf [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium)

    2009-10-15

    A powerful method to study carbon nanotubes (CNTs) grown in patterned substrates for potential interconnects applications is transmission electron microscopy (TEM). However, high-quality TEM samples are necessary for such a study. Here, TEM specimen preparation by focused ion beam (FIB) has been used to obtain lamellae of patterned samples containing CNTs grown inside contact holes. A dual-cap Pt protection layer and an extensive 5 kV cleaning procedure are applied in order to preserve the CNTs and avoid deterioration during milling. TEM results show that the inner shell structure of the carbon nanotubes has been preserved, which proves that focused ion beam is a useful technique to prepare TEM samples of CNT interconnects.

  18. Proficiency Testing by Interlaboratory Comparison Performed in 2010-2015 for Neutron Activation Analysis and Other Analytical Techniques

    International Nuclear Information System (INIS)

    2017-12-01

    The IAEA supports its Member States to increase the utilization of their research reactors. Small and medium sized reactors are mostly used for neutron activation analysis (NAA). Although the markets for NAA laboratories have been identified, demonstration of valid analytical results and organizational quality of the work process are preconditions for expanding the stakeholder community, particularly in commercial routine application of this powerful technique. The IAEA has implemented a new mechanism for supporting NAA laboratories in demonstrating their analytical performance by participation in proficiency testing schemes by interlaboratory comparison. This activity makes possible the identification of deviations and non-conformities, their causes and the process to implement effective approaches to eliminate them. Over 30 laboratories participated between 2010 and 2015 in consecutive proficiency tests organized by the IAEA in conjunction with the Wageningen Evaluating Programmes for Analytical Laboratories (WEPAL) to assess their analytical performances. This publication reports the findings and includes lessons learned of this activity. An attached CD-ROM contains many individual participating laboratory papers sharing their individual results and experience gained through this participation.

  19. Analytical Tem Comparisons of Stress-Corrosion-Crack Microstructures in Alloy 600 under Steam-Generator Service and Laboratory Test Conditions

    International Nuclear Information System (INIS)

    Thomas, L.E.; Bruemmer, S.M.; Scott, P.M.

    2002-01-01

    High-resolution analytical transmission electron microscopy (ATEM) has been used to characterize stress-corrosion cracks (SCC) in Alloy 600 steam-generator (SG) tubing from tests with caustic and acid-sulfate solutions. The aim of this work was to identify the microstructural and microchemical signatures of intergranular attack and cracking produced under well-controlled test conditions in order to determine the local environments promoting degradation in service. Cross-sectioned cracks and crack tips were examined in samples of mill-annealed alloy 600 tested in concentrated caustic and acid-sulfate solutions at 320 C. Characteristic microstructures observed in the caustic (10% NaOH) test sample included deeply penetrative attack along crack-intersected grain boundaries, with Cr-rich spinel and NiO structure oxides ranging from random nanocrystalline to oriented epitaxial films filling cracks up to the tips. Sodium was readily detectable in the oxides (up to 5 wt.% in the spinel corrosion product) along with S and Cu enrichment at crack-wall metal/oxide interfaces and local attack of the metal matrix around IG carbide particles. In the sulfate (Na 2 SO 4 + FeSO 4 ) test sample, the grain boundaries were also deeply attacked/cracked. Epitaxial NiO-structure oxide formed on the crack walls and S, sometimes with Cu, was concentrated between the oriented oxide layers rather than along the metal/oxide interfaces. Carbides were attacked and partially converted to fine-grained oxide containing up to several percent S. Observations of crack tips in the acid sulfate sample also revealed nm-wide cracks preceding the oxide along grain boundaries. The SCC structures produced in the laboratory tests differed in most details from the secondary-side SCC structures observed in pulled SG tubes. Important differences included the oxide morphologies, the presence of easily detectable Na and absence of sulfides in the test samples, different types of attack on IG carbide particles

  20. Fatigue crack extension in nozzle junctions; comparison of analytical approximations with experimental data

    International Nuclear Information System (INIS)

    Broekhoven, M.J.G.; Ruijtenbeek, M.G. van de

    1975-01-01

    The fracture mechanics based stress intensity factor (K-factor) concept has obtained wide-spread acceptance as a tool for quantitative analysis of both fatigue crack growth and instable fracture. The present study discusses the applicability of various simple analytical approximations by comparing results with experimental data. A semi-analytical procedure has been developed whose main characteristics are: the true stress distribution perpendicular to the crack plane for the uncracked structure is used as input data; an extended version of the Shah and Kobayashi solution for elliptical cracks, loaded on their surfaces by tractions described by fourth order double symmetrical polynomials fit through the data of previous step is used to calculate full K-factor variations along the crack fronts; several corrections, a.o. to correct for free surfaces and for a corner radius are incorporated. The experiments concern careful monitoring crack growth rates (da/dN) under uniaxial fatigue loading of precracked nozzle-on-plate models, a.o. using a closed T.V. circuit. Resulting da/dN versus crack length (a) curves are converted into K versus a curves using da/dN versus ΔK curves for the same material (ASTM A 508 C12) obtained by standard procedures. Comparison of theoretical and experimental data yields the conclusion that: simple analytical approximations as sometimes recommended in literature may largely overestimate or underestimate K-factors for nozzle corner cracks; a computer program based on the semi-analytical procedure yields results within seconds of CPU-time once the input data have been generated. These results compare well with experimental and available finite element data for the range of crack depths of practical concern

  1. Characterization of TEM1/endosialin in human and murine brain tumors

    International Nuclear Information System (INIS)

    Carson-Walter, Eleanor B; Walter, Kevin A; Winans, Bethany N; Whiteman, Melissa C; Liu, Yang; Jarvela, Sally; Haapasalo, Hannu; Tyler, Betty M; Huso, David L; Johnson, Mahlon D

    2009-01-01

    TEM1/endosialin is an emerging microvascular marker of tumor angiogenesis. We characterized the expression pattern of TEM1/endosialin in astrocytic and metastatic brain tumors and investigated its role as a therapeutic target in human endothelial cells and mouse xenograft models. In situ hybridization (ISH), immunohistochemistry (IH) and immunofluorescence (IF) were used to localize TEM1/endosialin expression in grade II-IV astrocytomas and metastatic brain tumors on tissue microarrays. Changes in TEM1/endosialin expression in response to pro-angiogenic conditions were assessed in human endothelial cells grown in vitro. Intracranial U87MG glioblastoma (GBM) xenografts were analyzed in nude TEM1/endosialin knockout (KO) and wildtype (WT) mice. TEM1/endosialin was upregulated in primary and metastatic human brain tumors, where it localized primarily to the tumor vasculature and a subset of tumor stromal cells. Analysis of 275 arrayed grade II-IV astrocytomas demonstrated TEM1/endosialin expression in 79% of tumors. Robust TEM1/endosialin expression occurred in 31% of glioblastomas (grade IV astroctyomas). TEM1/endosialin expression was inversely correlated with patient age. TEM1/endosialin showed limited co-localization with CD31, αSMA and fibronectin in clinical specimens. In vitro, TEM1/endosialin was upregulated in human endothelial cells cultured in matrigel. Vascular Tem1/endosialin was induced in intracranial U87MG GBM xenografts grown in mice. Tem1/endosialin KO vs WT mice demonstrated equivalent survival and tumor growth when implanted with intracranial GBM xenografts, although Tem1/endosialin KO tumors were significantly more vascular than the WT counterparts. TEM1/endosialin was induced in the vasculature of high-grade brain tumors where its expression was inversely correlated with patient age. Although lack of TEM1/endosialin did not suppress growth of intracranial GBM xenografts, it did increase tumor vascularity. The cellular localization of TEM1

  2. Bayesian resolution of TEM, CSEM and MT soundings: a comparative study

    Science.gov (United States)

    Blatter, D. B.; Ray, A.; Key, K.

    2017-12-01

    We examine the resolution of three electromagnetic exploration methods commonly used to map the electrical conductivity of the shallow crust - the magnetotelluric (MT) method, the controlled-source electromagnetic (CSEM) method and the transient electromagnetic (TEM) method. TEM and CSEM utilize an artificial source of EM energy, while MT makes use of natural variations in the Earth's electromagnetic field. For a given geological setting and acquisition parameters, each of these methods will have a different resolution due to differences in the source field polarization and the frequency range of the measurements. For example, the MT and TEM methods primarily rely on induced horizontal currents and are most sensitive to conductive layers while the CSEM method generates vertical loops of current and is more sensitive to resistive features. Our study seeks to provide a robust resolution comparison that can help inform exploration geophysicists about which technique is best suited for a particular target. While it is possible to understand and describe a difference in resolution qualitatively, it remains challenging to fully describe it quantitatively using optimization based approaches. Part of the difficulty here stems from the standard electromagnetic inversion toolkit, which makes heavy use of regularization (often in the form of smoothing) to constrain the non-uniqueness inherent in the inverse problem. This regularization makes it difficult to accurately estimate the uncertainty in estimated model parameters - and therefore obscures their true resolution. To overcome this difficulty, we compare the resolution of CSEM, airborne TEM, and MT data quantitatively using a Bayesian trans-dimensional Markov chain Monte Carlo (McMC) inversion scheme. Noisy synthetic data for this study are computed from various representative 1D test models: a conductive anomaly under a conductive/resistive overburden; and a resistive anomaly under a conductive/resistive overburden. In

  3. Comparison of nuclear analytical methods with competitive methods

    International Nuclear Information System (INIS)

    1987-10-01

    The use of nuclear analytical techniques, especially neutron activation analysis, already have a 50 year old history. Today several sensitive and accurate, non-nuclear trace element analytical techniques are available and new methods are continuously developed. The IAEA is supporting the development of nuclear analytical laboratories in its Member States. In order to be able to advise the developing countries which methods to use in different applications, it is important to know the present status and development trends of nuclear analytical methods, what are their benefits, drawbacks and recommended fields of application, compared with other, non-nuclear techniques. In order to get an answer to these questions the IAEA convened this Advisory Group Meeting. This volume is the outcome of the presentations and discussions of the meeting. A separate abstract was prepared for each of the 21 papers. Refs, figs, tabs

  4. Applicability of analytical instrument in trace evidence analysis

    International Nuclear Information System (INIS)

    Sharma, Mukesh; Jha, Shailendra

    2014-01-01

    In the present paper, we explain the importance of the analytical instrument used in the field of forensic science for the analysis of the trace evidences collected from the scene of occurrence. The forensic scientist has to rely upon these instrumental analyses of trace amounts of materials like drugs, toxicological specimens, GSR, fibres, glass, paints, soil etc. Through this paper, reviews on these techniques which are extensively used in forensic sciences are reported. Our report summaries on the basis of analytical problem facing for a forensic expert and techniques employed to tackle them like XRD/XRF, inductively coupled plasma (ICP) techniques, Raman spectroscopy and microscopy (optical, GRIM, electron microscopy, TEM). (author)

  5. On Thermally Interacting Multiple Boreholes with Variable Heating Strength: Comparison between Analytical and Numerical Approaches

    Directory of Open Access Journals (Sweden)

    Marc A. Rosen

    2012-08-01

    Full Text Available The temperature response in the soil surrounding multiple boreholes is evaluated analytically and numerically. The assumption of constant heat flux along the borehole wall is examined by coupling the problem to the heat transfer problem inside the borehole and presenting a model with variable heat flux along the borehole length. In the analytical approach, a line source of heat with a finite length is used to model the conduction of heat in the soil surrounding the boreholes. In the numerical method, a finite volume method in a three dimensional meshed domain is used. In order to determine the heat flux boundary condition, the analytical quasi-three-dimensional solution to the heat transfer problem of the U-tube configuration inside the borehole is used. This solution takes into account the variation in heating strength along the borehole length due to the temperature variation of the fluid running in the U-tube. Thus, critical depths at which thermal interaction occurs can be determined. Finally, in order to examine the validity of the numerical method, a comparison is made with the results of line source method.

  6. Novel sample preparation for operando TEM of catalysts.

    Science.gov (United States)

    Miller, Benjamin K; Barker, Trevor M; Crozier, Peter A

    2015-09-01

    A new TEM sample preparation method is developed to facilitate operando TEM of gas phase catalysis. A porous Pyrex-fiber pellet TEM sample was produced, allowing a comparatively large amount of catalyst to be loaded into a standard Gatan furnace-type tantalum heating holder. The increased amount of catalyst present inside the environmental TEM allows quantitative determination of the gas phase products of a catalytic reaction performed in-situ at elevated temperatures. The product gas concentration was monitored using both electron energy loss spectroscopy (EELS) and residual gas analysis (RGA). Imaging of catalyst particles dispersed over the pellet at atomic resolution is challenging, due to charging of the insulating glass fibers. To overcome this limitation, a metal grid is placed into the holder in addition to the pellet, allowing catalyst particles dispersed over the grid to be imaged, while particles in the pellet, which are assumed to experience identical conditions, contribute to the overall catalytic conversion inside the environmental TEM cell. The gas within the cell is determined to be well-mixed, making this assumption reasonable. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. A-10/TF34 Turbine Engine Monitoring System (TEMS)

    Science.gov (United States)

    Christopher, R. G.

    1981-01-01

    The hardware and software development of the A-10/TF34 turbine engine monitoring system (TEMS) is described. The operation and interfaces of the A-10/TF34 TEMS hardware are discussed with particular emphasis on function, capabilities, and limitations. The TEMS data types are defined and the various data acquisition modes are explained. Potential data products are also discussed.

  8. In-situ TEM Studies : Heat-treatment and Corrosion

    NARCIS (Netherlands)

    Malladi, S.R.K.

    2014-01-01

    Transmission electron microscopy (TEM) has been well known as a powerful characterisation tool to understand the structure and composition of various materials down to the atomic level. Over the years, several TEM studies have been carried out to understand the compositional, structural and

  9. Indications and techniques of transanal endoscopic microsurgery (TEMS).

    Science.gov (United States)

    Qi, Yanjie; Stoddard, David; Monson, John R T

    2011-08-01

    Transanal endoscopic microsurgery (TEMS) has recently reemerged as a valuable technique for the management of rectal neoplasms - both benign and malignant. Since the original description of this technique in the early 1980s, TEMS has emerged as the approach of choice for most benign rectal tumors because of the excellent views provided and superior dissection techniques possible when compared to traditional transanal excision. Many published reports demonstrate that the lowest rates of recurrence are associated with TEMS probably because of full-thickness excision with negative margins. Increasingly, TEMS is being applied to primary rectal cancer when used alone as a full-thickness excision alone or in combination with additional therapies, depending on tumor stage. There is now a significant evidence base to suggest that this approach should be considered as part of a multidisciplinary approach to rectal cancer. This paper describes indications and techniques for this technology.

  10. Rigid inclusions-Comparison between analytical and numerical methods

    International Nuclear Information System (INIS)

    Gomez Perez, R.; Melentijevic, S.

    2014-01-01

    This paper compares different analytical methods for analysis of rigid inclusions with finite element modeling. First of all, the load transfer in the distribution layer is analyzed for its different thicknesses and different inclusion grids to define the range between results obtained by analytical and numerical methods. The interaction between the soft soil and the inclusion in the estimation of settlements is studied as well. Considering different stiffness of the soft soil, settlements obtained analytical and numerically are compared. The influence of the soft soil modulus of elasticity on the neutral point depth was also performed by finite elements. This depth has a great importance for the definition of the total length of rigid inclusion. (Author)

  11. Preparation of carbon-free TEM microgrids by metal sputtering

    International Nuclear Information System (INIS)

    Janbroers, S.; Kruijff, T.R. de; Xu, Q.; Kooyman, P.J.; Zandbergen, H.W.

    2009-01-01

    A new method for preparing carbon-free, temperature-stable Transmission Electron Microscope (TEM) grids is presented. An 80% Au/20% Pd metal film is deposited onto a 'holey' microgrid carbon supported on standard mixed-mesh Au TEM grids. Subsequently, the carbon film is selectively removed using plasma cleaning. In this way, an all-metal TEM film is made containing the 'same' microgrid as the original carbon film. Although electron transparency of the foil is reduced significantly, the open areas for TEM inspection of material over these areas are maintained. The metal foil can be prepared with various thicknesses and ensures good electrical conductivity. The new Au/Pd grids are stable to at least 775 K under vacuum conditions.

  12. Preparation of carbon-free TEM microgrids by metal sputtering.

    Science.gov (United States)

    Janbroers, S; de Kruijff, T R; Xu, Q; Kooyman, P J; Zandbergen, H W

    2009-08-01

    A new method for preparing carbon-free, temperature-stable Transmission Electron Microscope (TEM) grids is presented. An 80% Au/20% Pd metal film is deposited onto a 'holey' microgrid carbon supported on standard mixed-mesh Au TEM grids. Subsequently, the carbon film is selectively removed using plasma cleaning. In this way, an all-metal TEM film is made containing the 'same' microgrid as the original carbon film. Although electron transparency of the foil is reduced significantly, the open areas for TEM inspection of material over these areas are maintained. The metal foil can be prepared with various thicknesses and ensures good electrical conductivity. The new Au/Pd grids are stable to at least 775K under vacuum conditions.

  13. Focus-variation image reconstruction in field-emission TEM

    NARCIS (Netherlands)

    Coene, W.M.J.; Janssen, A.J.E.M.; Op de Beeck, M.; Van Dyck, D.; Van Zwet, E.J.; Zandbergen, H.W.; Bailey, G.W.; Rieder, C.L.

    1993-01-01

    The use of a field emission gun (FEG) in high resolution TEM (HRTEM) improves the information limit much below the point resolution. In the area between point and information resolution of the FEG-TEM, image interpretation is complicated by the lens aberrations and focus effects. Different

  14. ToTem: a tool for variant calling pipeline optimization.

    Science.gov (United States)

    Tom, Nikola; Tom, Ondrej; Malcikova, Jitka; Pavlova, Sarka; Kubesova, Blanka; Rausch, Tobias; Kolarik, Miroslav; Benes, Vladimir; Bystry, Vojtech; Pospisilova, Sarka

    2018-06-26

    High-throughput bioinformatics analyses of next generation sequencing (NGS) data often require challenging pipeline optimization. The key problem is choosing appropriate tools and selecting the best parameters for optimal precision and recall. Here we introduce ToTem, a tool for automated pipeline optimization. ToTem is a stand-alone web application with a comprehensive graphical user interface (GUI). ToTem is written in Java and PHP with an underlying connection to a MySQL database. Its primary role is to automatically generate, execute and benchmark different variant calling pipeline settings. Our tool allows an analysis to be started from any level of the process and with the possibility of plugging almost any tool or code. To prevent an over-fitting of pipeline parameters, ToTem ensures the reproducibility of these by using cross validation techniques that penalize the final precision, recall and F-measure. The results are interpreted as interactive graphs and tables allowing an optimal pipeline to be selected, based on the user's priorities. Using ToTem, we were able to optimize somatic variant calling from ultra-deep targeted gene sequencing (TGS) data and germline variant detection in whole genome sequencing (WGS) data. ToTem is a tool for automated pipeline optimization which is freely available as a web application at  https://totem.software .

  15. Parameter sampling capabilities of sequential and simultaneous data assimilation: I. Analytical comparison

    International Nuclear Information System (INIS)

    Fossum, Kristian; Mannseth, Trond

    2014-01-01

    We assess the parameter sampling capabilities of some Bayesian, ensemble-based, joint state-parameter (JS) estimation methods. The forward model is assumed to be non-chaotic and have nonlinear components, and the emphasis is on results obtained for the parameters in the state-parameter vector. A variety of approximate sampling methods exist, and a number of numerical comparisons between such methods have been performed. Often, more than one of the defining characteristics vary from one method to another, so it can be difficult to point out which characteristic of the more successful method in such a comparison was decisive. In this study, we single out one defining characteristic for comparison; whether or not data are assimilated sequentially or simultaneously. The current paper is concerned with analytical investigations into this issue. We carefully select one sequential and one simultaneous JS method for the comparison. We also design a corresponding pair of pure parameter estimation methods, and we show how the JS methods and the parameter estimation methods are pairwise related. It is shown that the sequential and the simultaneous parameter estimation methods are equivalent for one particular combination of observations with different degrees of nonlinearity. Strong indications are presented for why one may expect the sequential parameter estimation method to outperform the simultaneous parameter estimation method for all other combinations of observations. Finally, the conditions for when similar relations can be expected to hold between the corresponding JS methods are discussed. A companion paper, part II (Fossum and Mannseth 2014 Inverse Problems 30 114003), is concerned with statistical analysis of results from a range of numerical experiments involving sequential and simultaneous JS estimation, where the design of the numerical investigation is motivated by our findings in the current paper. (paper)

  16. Analytic modeling, simulation and interpretation of broadband beam coupling impedance bench measurements

    Energy Technology Data Exchange (ETDEWEB)

    Niedermayer, U., E-mail: niedermayer@temf.tu-darmstadt.de [Institut für Theorie Elektromagnetischer Felder (TEMF), Technische Universität Darmstadt, Schloßgartenstraße 8, 64289 Darmstadt (Germany); Eidam, L. [Institut für Theorie Elektromagnetischer Felder (TEMF), Technische Universität Darmstadt, Schloßgartenstraße 8, 64289 Darmstadt (Germany); Boine-Frankenheim, O. [Institut für Theorie Elektromagnetischer Felder (TEMF), Technische Universität Darmstadt, Schloßgartenstraße 8, 64289 Darmstadt (Germany); GSI Helmholzzentrum für Schwerionenforschung, Planckstraße 1, 64291 Darmstadt (Germany)

    2015-03-11

    First, a generalized theoretical approach towards beam coupling impedances and stretched-wire measurements is introduced. Applied to a circular symmetric setup, this approach allows to compare beam and wire impedances. The conversion formulas for TEM scattering parameters from measurements to impedances are thoroughly analyzed and compared to the analytical beam impedance solution. A proof of validity for the distributed impedance formula is given. The interaction of the beam or the TEM wave with dispersive material such as ferrite is discussed. The dependence of the obtained beam impedance on the relativistic velocity β is investigated and found as material property dependent. Second, numerical simulations of wakefields and scattering parameters are compared. The applicability of scattering parameter conversion formulas for finite device length is investigated. Laboratory measurement results for a circularly symmetric test setup, i.e. a ferrite ring, are shown and compared to analytic and numeric models. The optimization of the measurement process and error reduction strategies are discussed.

  17. A CRITICAL STUDY AND COMPARISON OF MANUFACTURING SIMULATION SOFTWARES USING ANALYTIC HIERARCHY PROCESS

    Directory of Open Access Journals (Sweden)

    ASHU GUPTA

    2010-03-01

    Full Text Available In a period of continuous change in global business environment, organizations, large and small, are finding it increasingly difficult to deal with, and adjust to the demands for such change. Simulation is a powerful tool for allowing designers imagines new systems and enabling them to both quantify and observe behavior. Currently the market offers a variety of simulation software packages. Some are less expensive than others. Some are generic and can be used in a wide variety of application areas while others are more specific. Some have powerful features for modeling while others provide only basic features. Modeling approaches and strategies are different for different packages. Companies are seeking advice about the desirable features of software for manufacturing simulation, depending on the purpose of its use. Because of this, the importance of an adequate approach to simulation software evaluation and comparison is apparent. This paper presents a critical evaluation of four widely used manufacturing simulators: NX-IDEAS, Star-CD, Micro Saint Sharp and ProModel. Following a review of research into simulation software evaluation, an evaluation and comparison of the above simulators is performed. This paper illustrates and assesses the role the Analytic Hierarchy Process (AHP played in simulation software evaluation and selection. The main purpose of this evaluation and comparison is to discover the suitability of certain types of simulators for particular purposes.

  18. Preparation of carbon-free TEM microgrids by metal sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Janbroers, S., E-mail: stephan.janbroers@albemarle.com [Albemarle Catalysts B.V., Nieuwendammerkade 1-3, 1030 BE, Amsterdam (Netherlands); Kavli Institute of Nanoscience, Delft University of Technology, Lorentzweg 1, 2628 CJ Delft (Netherlands); Kruijff, T.R. de; Xu, Q. [Kavli Institute of Nanoscience, Delft University of Technology, Lorentzweg 1, 2628 CJ Delft (Netherlands); Kooyman, P.J. [DelftChemTech, Delft University of Technology, Julianalaan 136, 2628 BL, Delft (Netherlands); Kavli Institute of Nanoscience, Delft University of Technology, Lorentzweg 1, 2628 CJ Delft (Netherlands); Zandbergen, H.W. [Kavli Institute of Nanoscience, Delft University of Technology, Lorentzweg 1, 2628 CJ Delft (Netherlands)

    2009-08-15

    A new method for preparing carbon-free, temperature-stable Transmission Electron Microscope (TEM) grids is presented. An 80% Au/20% Pd metal film is deposited onto a 'holey' microgrid carbon supported on standard mixed-mesh Au TEM grids. Subsequently, the carbon film is selectively removed using plasma cleaning. In this way, an all-metal TEM film is made containing the 'same' microgrid as the original carbon film. Although electron transparency of the foil is reduced significantly, the open areas for TEM inspection of material over these areas are maintained. The metal foil can be prepared with various thicknesses and ensures good electrical conductivity. The new Au/Pd grids are stable to at least 775 K under vacuum conditions.

  19. Regulation of ETG turbulence by TEM driven zonal flows

    Science.gov (United States)

    Asahi, Yuuichi; Ishizawa, Akihiro; Watanabe, Tomohiko; Tsutsui, Hiroaki; Tsuji-Iio, Shunji

    2013-10-01

    Anomalous heat transport driven by electron temperature gradient (ETG) turbulence is investigated by means of gyrokinetic simulations. It is found that the ETG turbulence can be suppressed by zonal flows driven by trapped electron modes (TEMs). The TEMs appear in a statistically steady state of ETG turbulence and generate zonal flows, while its growth rate is much smaller than those of ETGs. The TEM-driven zonal flows with lower radial wave numbers are more strongly generated than those driven by ETG modes, because of the higher zonal flow response to a density source term. An ExB shearing rate of the TEM-driven zonal flows is strong enough to suppress the long-wavelength ETG modes which make the main contribution to the turbulent transport.

  20. Performance of a field emission gun TEM/STEM

    International Nuclear Information System (INIS)

    Carpenter, R.W.; Bentley, J.

    1979-01-01

    First experimental results on a Phillips EM 400 TEM/STEM fitted with a field-emission electron gun and objective twin lens are given here. Operation of the FEG is reliable up to maximum design voltage (120 kV). Highest resolution achieved in TEM was 1.9 A fringe. A wide variety of diffraction modes were demonstrated, ranging from CBDP from a small area (approx. 10 A dia) in STEM mode to SAD with angular resolution of 8 μrad in TEM mode. The EDS sensitivity is very high. STEM imaging performance to the highest magnifications examined (200 kx) is good. Work is in progress to evaluate the limits of STEM performance

  1. Results of an interlaboratory comparison of analytical methods for contaminants of emerging concern in water.

    Science.gov (United States)

    Vanderford, Brett J; Drewes, Jörg E; Eaton, Andrew; Guo, Yingbo C; Haghani, Ali; Hoppe-Jones, Christiane; Schluesener, Michael P; Snyder, Shane A; Ternes, Thomas; Wood, Curtis J

    2014-01-07

    An evaluation of existing analytical methods used to measure contaminants of emerging concern (CECs) was performed through an interlaboratory comparison involving 25 research and commercial laboratories. In total, 52 methods were used in the single-blind study to determine method accuracy and comparability for 22 target compounds, including pharmaceuticals, personal care products, and steroid hormones, all at ng/L levels in surface and drinking water. Method biases ranged from caffeine, NP, OP, and triclosan had false positive rates >15%. In addition, some methods reported false positives for 17β-estradiol and 17α-ethynylestradiol in unspiked drinking water and deionized water, respectively, at levels higher than published predicted no-effect concentrations for these compounds in the environment. False negative rates were also generally contamination, misinterpretation of background interferences, and/or inappropriate setting of detection/quantification levels for analysis at low ng/L levels. The results of both comparisons were collectively assessed to identify parameters that resulted in the best overall method performance. Liquid chromatography-tandem mass spectrometry coupled with the calibration technique of isotope dilution were able to accurately quantify most compounds with an average bias of <10% for both matrixes. These findings suggest that this method of analysis is suitable at environmentally relevant levels for most of the compounds studied. This work underscores the need for robust, standardized analytical methods for CECs to improve data quality, increase comparability between studies, and help reduce false positive and false negative rates.

  2. Comparison of NMR simulations of porous media derived from analytical and voxelized representations.

    Science.gov (United States)

    Jin, Guodong; Torres-Verdín, Carlos; Toumelin, Emmanuel

    2009-10-01

    We develop and compare two formulations of the random-walk method, grain-based and voxel-based, to simulate the nuclear-magnetic-resonance (NMR) response of fluids contained in various models of porous media. The grain-based approach uses a spherical grain pack as input, where the solid surface is analytically defined without an approximation. In the voxel-based approach, the input is a computer-tomography or computer-generated image of reconstructed porous media. Implementation of the two approaches is largely the same, except for the representation of porous media. For comparison, both approaches are applied to various analytical and digitized models of porous media: isolated spherical pore, simple cubic packing of spheres, and random packings of monodisperse and polydisperse spheres. We find that spin magnetization decays much faster in the digitized models than in their analytical counterparts. The difference in decay rate relates to the overestimation of surface area due to the discretization of the sample; it cannot be eliminated even if the voxel size decreases. However, once considering the effect of surface-area increase in the simulation of surface relaxation, good quantitative agreement is found between the two approaches. Different grain or pore shapes entail different rates of increase of surface area, whereupon we emphasize that the value of the "surface-area-corrected" coefficient may not be universal. Using an example of X-ray-CT image of Fontainebleau rock sample, we show that voxel size has a significant effect on the calculated surface area and, therefore, on the numerically simulated magnetization response.

  3. Retrofit implementation of Zernike phase plate imaging for cryo-TEM.

    Science.gov (United States)

    Marko, Michael; Leith, Ardean; Hsieh, Chyongere; Danev, Radostin

    2011-05-01

    In-focus phase-plate imaging is particularly beneficial for cryo-TEM because it offers a substantial overall increase in image contrast, without an electron dose penalty, and it simplifies image interpretation. We show how phase-plate cryo-TEM can be implemented with an appropriate existing TEM, and provide a basic practical introduction to use of thin-film (carbon) phase plates. We point out potential pitfalls of phase-plate operation, and discuss solutions. We provide information on evaluating a particular TEM for its suitability. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Experimental study on propagation properties of large size TEM antennas

    International Nuclear Information System (INIS)

    Zhang Guowei; Wang Haiyang; Chen Weiqing; Wang Wei; Zhu Xiangqin; Xie Linshen

    2014-01-01

    The propagation properties of large size TEM antennas were studied by experiment. The size of the TEM antennas is 60 m × 20 m × 10 m and the character Impedance is 120 Ω. A kind of dielectric foil switch is designed compactly with TEM antennas which can generate double exponential waveform with altitude of 10 kV and rise time of l.2 ns. The radiated field distribution was measured. The relationship between rise time/altitude and distance were provided, and the propagation properties of large size TEM antennas were summarized. (authors)

  5. Transmission Electron Microscopy for Wood and Fiber Analysis − A Review

    Directory of Open Access Journals (Sweden)

    Mehedi Reza

    2015-07-01

    Full Text Available This review describes use of transmission electron microscopy (TEM in wood and fiber analysis. Analytical techniques and sample preparation methods are used to localize substructures of the cell wall polymers and are discussed in this review. The ultrastructural features of the wood cell walls, the structures formed by microfibrils, and the distribution of cell wall polymers, as revealed by TEM, are covered. Research investigating the distribution of lignin in tension and compression woods using TEM is reviewed. Different kinds of wood biodegrading enzymes localized using TEM are mentioned. Additional features of TEM, i.e., 3D imaging, analytical TEM, and electron diffraction are discussed. Lastly, a comparison between TEM and other imaging techniques used for wood and fiber research are made. Thus, this review provides insight into the contribution of TEM in wood research since its invention and demonstrates how to use it more effectively in the future.

  6. Comparison of analytical transport and stochastic solutions for neutron slowing down in an infinite medium

    International Nuclear Information System (INIS)

    Jahshan, S.N.; Wemple, C.A.; Ganapol, B.D.

    1993-01-01

    A comparison of the numerical solutions of the transport equation describing the steady neutron slowing down in an infinite medium with constant cross sections is made with stochastic solutions obtained from tracking successive neutron histories in the same medium. The transport equation solution is obtained using a numerical Laplace transform inversion algorithm. The basis for the algorithm is an evaluation of the Bromwich integral without analytical continuation. Neither the transport nor the stochastic solution is limited in the number of scattering species allowed. The medium may contain an absorption component as well. (orig.)

  7. Microstructural differences between two Zr(C,N) coatings revealed by analytical transmission electron microscopy

    International Nuclear Information System (INIS)

    Dörfel, Ilona; Rooch, Heidemarie; Österle, Werner

    2012-01-01

    The microstructures of two samples of a Zr(C,N) coating on steel, which unexpectedly differed in their tribological properties, were investigated by analytical transmission electron microscopy. The samples were produced by a cathodic arc evaporation process in two commercial coating devices under similar coating conditions with the exception of the number of Zr targets. The source of the differing tribological properties of the samples was detected by analytical transmission electron microscopy (TEM) methods energy-dispersive X-ray spectroscopy (EDX), energy filtering TEM (EFTEM), electron diffraction, high resolution electron microscopy, and high angel annular dark field. The TEM preparation and the results of the TEM investigations are shown in detail. The origin of the unexpected behavior was determined to be a nano-scale multilayer structure that existed only in the tribologically superior specimen. EDX and EFTEM investigations indicated enrichment in oxygen at the interface between coating and steel substrate in the tribologically inferior sample. Findings of the microstructural configuration were obtained by taking a closer look at the structure and comparing the results of the several analytical TEM techniques. This allows the allocation of the concentration fluctuations in N, C, and Zr to the two thickness fractions of the nano multilayers and a local correlation of the identified minority phase Zr 3 (C,N) 4 to the higher N content in the narrower type of the multilayer fraction of the sample with the excellent tribological properties. The minority phase Zr 3 (C,N) 4 is randomly distributed in the sample with the defective tribological properties. Coating conditions are not topic of this work, but after discussion of the TEM results, the fact that one of the coating devices worked with one Zr target and the other one with two, could be identified as cause for the formation of the nano multilayer structure in the sample with the superior tribological

  8. Investigations of oxide particles in unirradiated ODS-Eurofer by TEM and 3D atom probe methods

    International Nuclear Information System (INIS)

    Aleev, A.A.; Iskandarov, N.A.; Nikitin, A.A.; Rogizhkin, S.V.; Zaluzhny, A.G.; Klimenkov, M.; Lindau, R.; Moeslang, A.; Vladimirov, P.

    2009-01-01

    Oxide dispersion strengthened steels possess better high-temperature creep and radiation resistance than conventionally produced ferritic/martensitic steels. This behavior is mainly caused by the presence of highly dispersed and extremely stable oxide particles with sizes of few nanometers. One of the promising oxides used for dispersion strengthening was yttria (Y 2 O 3 ), which was introduced into EUROFER by mechanical alloying followed by the hot isostatic pressing at temperature around 1000-1200 dg. C and pressure ∼100 MPa. It was found that mechanical properties were strongly depended on size and spatial distribution of the precipitates. Therefore considerable efforts are focused on the investigation of the chemical composition and orientation of precipitates with respect to the steel matrix. Recent studies of Eurofer ODS steel (9%-CrWVTa) by SANS revealed the presence of high number density structural features with a size of approximately one nanometer. At the same time, previous studies by TEM identified only high number of small (6-40 nm) Y 2 O 3 particles. In this work we tried to get a deeper inside into the nanostructure of this material by means of tomographic atom probe and to correlate the results with the picture obtained by TEM. The present investigations revealed fine (∼2 nm) enrichments containing not only yttrium and oxygen but also vanadium and nitrogen. Concentration of vanadium was found to be approximately at the same level as yttrium. Some of the enrichments contained only three or even two elements mentioned above. Estimated number density of enrichments is about (1/5) x 10 23 m -3 . We suppose that these enriched zones might be precursors of the larger precipitates observed by TEM. The thesis seems to be supported by the similarities of the chemical composition and spatial distribution of elements inside enriched zones and nano precipitates studied by atomic probe and analytical TEM methods. (author)

  9. Proof of U(VI) sorption on Acidovorax facilis by TRLFS and EF-TEM/EELS

    Energy Technology Data Exchange (ETDEWEB)

    Krawczyk-Baersch, Evelyn; Gerber, Ulrike [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany). Div. Biogeochemistry; Steudtner, Robin [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany). Div. Surface Processes

    2016-07-01

    In EF-TEM/EELS studies it was shown that U(VI) is sorbed mainly on the outer membrane of Acidovorax facilis. The results are supported by TRLFS measurements, which were performed on the pellet of the cells. In comparison to reference spectra of some cell membrane components, the measured emission spectra of the A. facilis pellet show the best agreement with those of the Uranyl-lipopolysaccharide-complex. Hence, it can be concluded that phosphoryl groups may be the main binding sites for uranyl, located in the lipopolysaccharide unit in the outer membrane.

  10. A comparison of two nodal codes : Advanced nodal code (ANC) and analytic function expansion nodal (AFEN) code

    International Nuclear Information System (INIS)

    Chung, S.K.; Hah, C.J.; Lee, H.C.; Kim, Y.H.; Cho, N.Z.

    1996-01-01

    Modern nodal methods usually employs the transverse integration technique in order to reduce a multi-dimensional diffusion equation to one-dimensional diffusion equations. The use of the transverse integration technique requires two major approximations such as a transverse leakage approximation and a one-dimensional flux approximation. Both the transverse leakage and the one-dimensional flux are approximated by polynomials. ANC (Advanced Nodal Code) developed by Westinghouse employs a modern nodal expansion method for the flux calculation, the equivalence theory for the homogenization error reduction and a group theory for pin power recovery. Unlike the conventional modern nodal methods, AFEN (Analytic Function Expansion Nodal) method expands homogeneous flux distributions within a node into non-separable analytic basis functions, which eliminate two major approximations of the modern nodal methods. A comparison study of AFEN with ANC has been performed to see the applicability of AFEN to commercial PWR and different types of reactors such as MOX fueled reactor. The qualification comparison results demonstrate that AFEN methodology is accurate enough to apply for commercial PWR analysis. The results show that AFEN provides very accurate results (core multiplication factor and assembly power distribution) for cores that exhibit strong flux gradients as in a MOX loaded core. (author)

  11. The application of in situ analytical transmission electron microscopy to the study of preferential intergranular oxidation in Alloy 600

    Energy Technology Data Exchange (ETDEWEB)

    Burke, M.G., E-mail: m.g.burke@manchester.ac.uk; Bertali, G.; Prestat, E.; Scenini, F.; Haigh, S.J.

    2017-05-15

    In situ analytical transmission electron microscopy (TEM) can provide a unique perspective on dynamic reactions in a variety of environments, including liquids and gases. In this study, in situ analytical TEM techniques have been applied to examine the localised oxidation reactions that occur in a Ni-Cr-Fe alloy, Alloy 600, using a gas environmental cell at elevated temperatures. The initial stages of preferential intergranular oxidation, shown to be an important precursor phenomenon for intergranular stress corrosion cracking in pressurized water reactors (PWRs), have been successfully identified using the in situ approach. Furthermore, the detailed observations correspond to the ex situ results obtained from bulk specimens tested in hydrogenated steam and in high temperature PWR primary water. The excellent agreement between the in situ and ex situ oxidation studies demonstrates that this approach can be used to investigate the initial stages of preferential intergranular oxidation relevant to nuclear power systems. - Highlights: • In situ analytical TEM has been performed in 1 bar H{sub 2}-H{sub 2}O vapor at 360–480 °C. • Nanoscale GB migration and solute partitioning correlate with ex situ data for Alloy 600 in H{sub 2}-steam. • This technique can provide new insights into localised reactions associated with localised oxidation.

  12. [Cross-cultural adaptation and apparent and content validity of the short version of The Eating Motivation Survey (TEMS) in Brazilian Portuguese].

    Science.gov (United States)

    Moraes, Jéssica Maria Muniz; Alvarenga, Marle Dos Santos

    2017-10-26

    Understanding why people eat what they eat is essential for developing nutritional guidelines capable of modifying inadequate and dysfunctional eating patterns. Such understanding can be assessed by specific instruments, amongst which The Eating Motivation Survey (TEMS) allows the identification of factors that determine motivations for eating and food choices. The aim of this study is to present the cross-cultural adaptation of the short version of TEMS for use in studies in the Brazilian population. The process involved conceptual and item equivalences; semantic equivalence by 2 translators, 1 linguist, 22 experts (frequency of response understanding), and 23 bilingual individuals (with response comparisons by the paired t-test, Pearson correlation coefficient, and intra-class correlation coefficient); and operational equivalence, performed with 32 individuals. The measurement equivalence corresponding to psychometric properties is under way. All equivalences showed satisfactory results for the scale's use in Brazil, thus allowing application of TEMS to assess motivations for eating choices in the Brazilian context.

  13. Investigation of diversity of plasmids carrying the blaTEM-52 gene

    DEFF Research Database (Denmark)

    Bielak, Eliza Maria; Bergenholtz, Rikke D.; Jørgensen, Mikael Skaanning

    2011-01-01

    OBJECTIVES: To investigate the diversity of plasmids that carry blaTEM-52 genes among Escherichia coli and Salmonella enterica originating from animals, meat products and humans. METHODS: A collection of 22 blaTEM-52-encoding plasmids was characterized by restriction fragment length polymorphism...... of self-transfer to a plasmid-free E. coli recipient. CONCLUSIONS: The blaTEM-52 gene found in humans could have been transmitted on transferable plasmids originating from animal sources. Some of the blaTEM-52 plasmids carry replicons that differ from the classical ones. Two novel replicons were detected...

  14. TH-A-19A-06: Site-Specific Comparison of Analytical and Monte Carlo Based Dose Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Schuemann, J; Grassberger, C; Paganetti, H [Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Dowdell, S [Illawarra Shoalhaven Local Health District, Wollongong (Australia)

    2014-06-15

    Purpose: To investigate the impact of complex patient geometries on the capability of analytical dose calculation algorithms to accurately predict dose distributions and to verify currently used uncertainty margins in proton therapy. Methods: Dose distributions predicted by an analytical pencilbeam algorithm were compared with Monte Carlo simulations (MCS) using TOPAS. 79 complete patient treatment plans were investigated for 7 disease sites (liver, prostate, breast, medulloblastoma spine and whole brain, lung and head and neck). A total of 508 individual passively scattered treatment fields were analyzed for field specific properties. Comparisons based on target coverage indices (EUD, D95, D90 and D50) were performed. Range differences were estimated for the distal position of the 90% dose level (R90) and the 50% dose level (R50). Two-dimensional distal dose surfaces were calculated and the root mean square differences (RMSD), average range difference (ARD) and average distal dose degradation (ADD), the distance between the distal position of the 80% and 20% dose levels (R80- R20), were analyzed. Results: We found target coverage indices calculated by TOPAS to generally be around 1–2% lower than predicted by the analytical algorithm. Differences in R90 predicted by TOPAS and the planning system can be larger than currently applied range margins in proton therapy for small regions distal to the target volume. We estimate new site-specific range margins (R90) for analytical dose calculations considering total range uncertainties and uncertainties from dose calculation alone based on the RMSD. Our results demonstrate that a reduction of currently used uncertainty margins is feasible for liver, prostate and whole brain fields even without introducing MC dose calculations. Conclusion: Analytical dose calculation algorithms predict dose distributions within clinical limits for more homogeneous patients sites (liver, prostate, whole brain). However, we recommend

  15. TH-A-19A-06: Site-Specific Comparison of Analytical and Monte Carlo Based Dose Calculations

    International Nuclear Information System (INIS)

    Schuemann, J; Grassberger, C; Paganetti, H; Dowdell, S

    2014-01-01

    Purpose: To investigate the impact of complex patient geometries on the capability of analytical dose calculation algorithms to accurately predict dose distributions and to verify currently used uncertainty margins in proton therapy. Methods: Dose distributions predicted by an analytical pencilbeam algorithm were compared with Monte Carlo simulations (MCS) using TOPAS. 79 complete patient treatment plans were investigated for 7 disease sites (liver, prostate, breast, medulloblastoma spine and whole brain, lung and head and neck). A total of 508 individual passively scattered treatment fields were analyzed for field specific properties. Comparisons based on target coverage indices (EUD, D95, D90 and D50) were performed. Range differences were estimated for the distal position of the 90% dose level (R90) and the 50% dose level (R50). Two-dimensional distal dose surfaces were calculated and the root mean square differences (RMSD), average range difference (ARD) and average distal dose degradation (ADD), the distance between the distal position of the 80% and 20% dose levels (R80- R20), were analyzed. Results: We found target coverage indices calculated by TOPAS to generally be around 1–2% lower than predicted by the analytical algorithm. Differences in R90 predicted by TOPAS and the planning system can be larger than currently applied range margins in proton therapy for small regions distal to the target volume. We estimate new site-specific range margins (R90) for analytical dose calculations considering total range uncertainties and uncertainties from dose calculation alone based on the RMSD. Our results demonstrate that a reduction of currently used uncertainty margins is feasible for liver, prostate and whole brain fields even without introducing MC dose calculations. Conclusion: Analytical dose calculation algorithms predict dose distributions within clinical limits for more homogeneous patients sites (liver, prostate, whole brain). However, we recommend

  16. Aberration-corrected STEM/TEM imaging at 15 kV

    International Nuclear Information System (INIS)

    Sasaki, Takeo; Sawada, Hidetaka; Hosokawa, Fumio; Sato, Yuta; Suenaga, Kazu

    2014-01-01

    The performance of aberration-corrected (scanning) transmission electron microscopy (S/TEM) at an accelerating voltage of 15 kV was evaluated in a low-voltage microscope equipped with a cold-field emission gun and a higher-order aberration corrector. Aberrations up to the fifth order were corrected by the aberration measurement and auto-correction system using the diffractogram tableau method in TEM and Ronchigram analysis in STEM. TEM observation of nanometer-sized particles demonstrated that aberrations up to an angle of 50 mrad were compensated. A TEM image of Si[110] exhibited lattice fringes with a spacing of 0.192 nm, and the power spectrum of the image showed spots corresponding to distances of 0.111 nm. An annular dark-field STEM image of Si[110] showed lattice fringes of (111) and (22¯0) planes corresponding to lattice distances of 0.314 nm and 0.192 nm, respectively. At an accelerating voltage of 15 kV, the developed low-voltage microscope achieved atomic-resolution imaging with a small chromatic aberration and a large uniform phase. - Highlights: • Aberration-corrected STEM/TEM imaging at 15 kV demonstrated lattice fringes of Si[110] single crystal with a spacing of 0.192 nm. • To achieve this performance at a lower accelerating voltage, uniform phase area over 50 mrad is mandatory in Ronchigram and Diffractogram tableau. • This means a higher-order aberration of six-fold astigmatism should be compensated. • In addition, decreasing the effect of chromatic aberration plays an important role for improving the performance of linear scattering component at 15 kV TEM

  17. Multielement trace determination in SiC powders: assessment of interlaboratory comparisons aimed at the validation and standardization of analytical procedures with direct solid sampling based on ETV ICP OES and DC arc OES.

    Science.gov (United States)

    Matschat, Ralf; Hassler, Jürgen; Traub, Heike; Dette, Angelika

    2005-12-01

    The members of the committee NMP 264 "Chemical analysis of non-oxidic raw and basic materials" of the German Standards Institute (DIN) have organized two interlaboratory comparisons for multielement determination of trace elements in silicon carbide (SiC) powders via direct solid sampling methods. One of the interlaboratory comparisons was based on the application of inductively coupled plasma optical emission spectrometry with electrothermal vaporization (ETV ICP OES), and the other on the application of optical emission spectrometry with direct current arc (DC arc OES). The interlaboratory comparisons were organized and performed in the framework of the development of two standards related to "the determination of mass fractions of metallic impurities in powders and grain sizes of ceramic raw and basic materials" by both methods. SiC powders were used as typical examples of this category of material. The aim of the interlaboratory comparisons was to determine the repeatability and reproducibility of both analytical methods to be standardized. This was an important contribution to the practical applicability of both draft standards. Eight laboratories participated in the interlaboratory comparison with ETV ICP OES and nine in the interlaboratory comparison with DC arc OES. Ten analytes were investigated by ETV ICP OES and eleven by DC arc OES. Six different SiC powders were used for the calibration. The mass fractions of their relevant trace elements were determined after wet chemical digestion. All participants followed the analytical requirements described in the draft standards. In the calculation process, three of the calibration materials were used successively as analytical samples. This was managed in the following manner: the material that had just been used as the analytical sample was excluded from the calibration, so the five other materials were used to establish the calibration plot. The results from the interlaboratory comparisons were summarized and

  18. Comparison of the effectiveness of analytical wake models for wind farm with constant and variable hub heights

    International Nuclear Information System (INIS)

    Wang, Longyan; Tan, Andy C.C.; Cholette, Michael; Gu, Yuantong

    2016-01-01

    Highlights: • The effectiveness of three analytical wake models is studied. • The results of the analytical wake models are compared with the CFD simulations. • The results of CFD simulation are verified by comparison to the offshore wind farm observation data. • The onshore wind farm with both constant and different hub height turbines are analyzed. • PARK model is able to predict the total wind farm power production well with tuned surface roughness value. - Abstract: Extensive power losses of wind farm have been witnessed due to the wake interactions between wind turbines. By applying analytical wake models which describe the wind speed deficits in the wake quantitatively, the power losses can be regained to a large extent through wind farm layout optimization, and this has been extensively reported in literature. Nevertheless, the effectiveness of the analytical wake models in predicting the wind farm power production have rarely been studied and compared for wind farm with both constant and variable wind turbine hub heights. In this study, the effectiveness of three different analytical wake models (PARK model, Larsen model and B-P model) is thoroughly compared over a wide range of wake properties. After the validation with the observation data from offshore wind farm, CFD simulations are used to verify the effectiveness of the analytical wake models for an onshore wind farm. The results show that when using the PARK model the surface roughness value (z 0 ) must be carefully tuned to achieve good performance in predicting the wind farm power production. For the other two analytical wake models, their effectiveness varies depending on the situation of wind farm (offshore or onshore) and the wind turbine hub heights (constant or variable). It was found that the results of B-P model agree well with the CFD simulations for offshore wind farm, but not for the onshore wind farm. The Larsen model is more accurate for the wind farm with variable wind turbine

  19. Tem holder for sample transfer under reaction conditions

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad; Zandbergen, Henny W.; Wagner, Jakob Birkedal

    Environmental transmission electron microscopy (ETEM) studies are usually performed using conventional sample holders in a dedicated ETEM [1] or in a traditional TEM by use of a dedicated high-pressure cell sample holder [2]. In both cases, the setup defines the conditions regarding gas, pressure......]. Furthermore, dedicated transfer holders have been used to transfer catalyst samples between reactor set-ups and TEM at room temperature in inert atmosphere [5]. To take the full advantage of complementary in situ techniques, transfer under reactions conditions is essential. This study introduces the in situ...... transfer concept by use of a dedicated TEM transfer holder capable of enclosing the sample in a gaseous environment at temperatures up to approx. 900C. By oxidation and reduction experiments of Cu nanoparticles it is shown possible to keep the reaction conditions during transfer outside the microscope...

  20. Molecular identification of TEM-116 beta-lactamase gene in isolates ...

    African Journals Online (AJOL)

    Keywords: P. aeruginosa, Clinical isolates, Sequencing, TEM-116, Antibiotic susceptibility. Tropical Journal of ... organisms produce a wide range of beta ... TEM-1 is the most commonly encountered beta-lactamase in Gram-negative bacteria.

  1. Multifractal analysis of CoFe2O4/2DBS/H2O ferrofluid from TEM and SANS measurements

    International Nuclear Information System (INIS)

    Stan, C.; Cristescu, C.P.; Balasoiu, M.; Ivankov, O.I.

    2015-01-01

    Preliminary investigation on the morphological properties and the multifractal characteristics of CoFe 2 O 4 nanoparticles, coated with a double layer of dodecylbenzenesulphonic acid and dispersed in double distillated water, is presented. TEM images of the sample are analyzed and the computed multifractal spectrum reveals universal multifractality. A comparison with the fractal approach applied to SANS data is presented, and consistency of results is demonstrated.

  2. Evaluation of analytical performance based on partial order methodology.

    Science.gov (United States)

    Carlsen, Lars; Bruggemann, Rainer; Kenessova, Olga; Erzhigitov, Erkin

    2015-01-01

    Classical measurements of performances are typically based on linear scales. However, in analytical chemistry a simple scale may be not sufficient to analyze the analytical performance appropriately. Here partial order methodology can be helpful. Within the context described here, partial order analysis can be seen as an ordinal analysis of data matrices, especially to simplify the relative comparisons of objects due to their data profile (the ordered set of values an object have). Hence, partial order methodology offers a unique possibility to evaluate analytical performance. In the present data as, e.g., provided by the laboratories through interlaboratory comparisons or proficiency testings is used as an illustrative example. However, the presented scheme is likewise applicable for comparison of analytical methods or simply as a tool for optimization of an analytical method. The methodology can be applied without presumptions or pretreatment of the analytical data provided in order to evaluate the analytical performance taking into account all indicators simultaneously and thus elucidating a "distance" from the true value. In the present illustrative example it is assumed that the laboratories analyze a given sample several times and subsequently report the mean value, the standard deviation and the skewness, which simultaneously are used for the evaluation of the analytical performance. The analyses lead to information concerning (1) a partial ordering of the laboratories, subsequently, (2) a "distance" to the Reference laboratory and (3) a classification due to the concept of "peculiar points". Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Fast FIB-milled Electron-transparent Microchips for in situ TEM Investigations

    DEFF Research Database (Denmark)

    Lei, Anders; Petersen, Dirch Hjorth; Kallesøe, Christian

    In this work we present a fast approach to 50 nm resolution structures defined in a generic TEM-chip template in few minutes. While creating complex electrical and NEMS circuits for a specific insitu TEM experiment can be a cumbersome process, microchips with 100 nm thin flakes of single crystall......In this work we present a fast approach to 50 nm resolution structures defined in a generic TEM-chip template in few minutes. While creating complex electrical and NEMS circuits for a specific insitu TEM experiment can be a cumbersome process, microchips with 100 nm thin flakes of single...

  4. A Comparison of Four Software Programs for Implementing Decision Analytic Cost-Effectiveness Models.

    Science.gov (United States)

    Hollman, Chase; Paulden, Mike; Pechlivanoglou, Petros; McCabe, Christopher

    2017-08-01

    The volume and technical complexity of both academic and commercial research using decision analytic modelling has increased rapidly over the last two decades. The range of software programs used for their implementation has also increased, but it remains true that a small number of programs account for the vast majority of cost-effectiveness modelling work. We report a comparison of four software programs: TreeAge Pro, Microsoft Excel, R and MATLAB. Our focus is on software commonly used for building Markov models and decision trees to conduct cohort simulations, given their predominance in the published literature around cost-effectiveness modelling. Our comparison uses three qualitative criteria as proposed by Eddy et al.: "transparency and validation", "learning curve" and "capability". In addition, we introduce the quantitative criterion of processing speed. We also consider the cost of each program to academic users and commercial users. We rank the programs based on each of these criteria. We find that, whilst Microsoft Excel and TreeAge Pro are good programs for educational purposes and for producing the types of analyses typically required by health technology assessment agencies, the efficiency and transparency advantages of programming languages such as MATLAB and R become increasingly valuable when more complex analyses are required.

  5. Complete Tem-Tomography: 3D Structure of Gems Cluster

    Science.gov (United States)

    Matsuno, J.; Miyake, A.; Tsuchiyama, A.; Messenger, S.; Nakamura-Messenger, K.

    2015-01-01

    GEMS (glass with embedded metal and sulfide) grains in interplanetary dust particles (IDPs) are considered to be one of the ubiquitous and fundamental building blocks of solids in the Solar System. They have been considered to be interstellar silicate dust that survived various metamorphism or alteration processes in the protoplanetary disk but the elemental and isotopic composition measurements suggest that most of them have been formed in the protoplanetary disk as condensates from high temperature gas. This formation model is also supported by the formation of GEMS-like grains with respect to the size, mineral assemblage, texture and infrared spectrum by condensation experiments from mean GEMS composition materials. Previous GEMS studies were performed only with 2D observation by transmission electron microscopy (TEM) or scanning TEM (STEM). However, the 3D shape and structure of GEMS grains and the spatial distribution of Fe/FeS's has critical information about their formation and origin. Recently, the 3D structure of GEMS grains in ultrathin sections of cluster IDPs was revealed by electron tomography using a TEM/STEM (JEM-2100F, JEOL). However, CT images of thin sections mounted on Cu grids acquired by conventional TEM-tomography are limited to low tilt angles (e. g., less than absolute value of 75 deg. In fact, previous 3D TEM observations of GEMS were affected by some artifacts related to the limited tilt range in the TEM used. Complete tomographic images should be acquired by rotating the sample tilt angle over a range of more than absolute value of 80 deg otherwise the CT images lose their correct structures. In order to constrain the origin and formation process of GEMS grains more clearly, we performed complete electron tomography for GEMS grains. Here we report the sample preparation method we have developed for this study, and the preliminary results.

  6. 2D Inversion of Transient Electromagnetic Method (TEM)

    Science.gov (United States)

    Bortolozo, Cassiano Antonio; Luís Porsani, Jorge; Acácio Monteiro dos Santos, Fernando

    2017-04-01

    A new methodology was developed for 2D inversion of Transient Electromagnetic Method (TEM). The methodology consists in the elaboration of a set of routines in Matlab code for modeling and inversion of TEM data and the determination of the most efficient field array for the problem. In this research, the 2D TEM modeling uses the finite differences discretization. To solve the inversion problem, were applied an algorithm based on Marquardt technique, also known as Ridge Regression. The algorithm is stable and efficient and it is widely used in geoelectrical inversion problems. The main advantage of 1D survey is the rapid data acquisition in a large area, but in regions with two-dimensional structures or that need more details, is essential to use two-dimensional interpretation methodologies. For an efficient field acquisition we used in an innovative form the fixed-loop array, with a square transmitter loop (200m x 200m) and 25m spacing between the sounding points. The TEM surveys were conducted only inside the transmitter loop, in order to not deal with negative apparent resistivity values. Although it is possible to model the negative values, it makes the inversion convergence more difficult. Therefore the methodology described above has been developed in order to achieve maximum optimization of data acquisition. Since it is necessary only one transmitter loop disposition in the surface for each series of soundings inside the loop. The algorithms were tested with synthetic data and the results were essential to the interpretation of the results with real data and will be useful in future situations. With the inversion of the real data acquired over the Paraná Sedimentary Basin (PSB) was successful realized a 2D TEM inversion. The results indicate a robust geoelectrical characterization for the sedimentary and crystalline aquifers in the PSB. Therefore, using a new and relevant approach for 2D TEM inversion, this research effectively contributed to map the most

  7. Molecular identification of TEM-116 beta-lactamase gene in isolates ...

    African Journals Online (AJOL)

    Purpose: Purpose: To determine TEM-116 beta-lactamase gene prevalence in drug-resistant Pseudomonas aeruginosa isolates from Pakistan. Methods: Sequence analysis of TEM beta-lactamase isolates and their antibiotic susceptibility patterns were carried out. Quantitative bacteriostatic concentrations for commonly ...

  8. Sensory-Analytical Comparison of the Aroma of Different Horseradish Varieties (Armoracia rusticana

    Directory of Open Access Journals (Sweden)

    Eva-Maria Kroener

    2018-05-01

    Full Text Available Horseradish (Armoracia rusticana is consumed and valued for the characteristic spicy aroma of its roots in many countries all over the world. In our present study we compare six different horseradish varieties that were grown under comparable conditions, with regard to their aroma profiles, using combined sensory-analytical methods. Horseradish extracts were analyzed through gas chromatography-olfactometry (GC-O and their aroma-active compounds ranked according to their smell potency using the concept of aroma extract dilution analysis (AEDA. Identification was carried out through comparison of retention indices, odor qualities and mass spectra with those of reference substances. Besides some differences in relative ratios, we observed some main odorants that were common to all varieties such as 3-isopropyl-2-methoxypyrazine and allyl isothiocyanate, but also characteristics for specific varieties such as higher contents for 3-isopropyl-2-methoxypyrazine in variety Nyehemes. Moreover, three odorous compounds were detected that have not been described in horseradish roots before.

  9. SOFC anode reduction studied by in situ TEM

    DEFF Research Database (Denmark)

    Simonsen, Søren Bredmose; Wagner, Jakob Birkedal; Hansen, Thomas Willum

    The Solid Oxide Fuel Cell (SOFC) is a promising part of future energy approaches due to a relatively high energy conversion efficiency and low environmental pollution. SOFCs are typically composed of ceramic materials which are highly complex at the nanoscale. TEM is routinely applied ex situ...... for studying these nanoscale structures, but only few SOFC studies have applied in situ TEM to observe the ceramic nanostructures in a reactive gas environment at elevated temperatures. The present contribution focuses on the reduction of an SOFC anode which is a necessary process to form the catalytically...... active Ni surface before operating the fuel cells. The reduction process was followed in the TEM while exposing a NiO/YSZ (YSZ = Y2O3-stabilized ZrO2) model anode to H2 at T = 250-1000⁰C. Pure NiO was used in reference experiments. Previous studies have shown that the reduction of pure Ni...

  10. Track Etch Membranes (TEMS) for separation sciences from BARC-TIFR Pelletron accelerator

    International Nuclear Information System (INIS)

    Nair, J.P.; Surendran, P.; Sparrow, Hillary; Gupta, A.K.; Kailas, S.; Bhagwat, P.V.

    2014-01-01

    TEMs are very much in need for the separation of desirable/undesirable metals from industrial effluents and radioactive wastes as well as in the field of biology and gas separation. It is necessary to optimize pore size and pore density for a specific application. TEMs available in market are imported and are used for laboratory scale activity. To carry the success of these activities on industrial scale large scale production of TEMs is needed. The availability of heavy ion accelerator made possible the production of TEMs in wide range of sizes. Many countries have set up facilities for continuous production of TEMs. BARC-TIFR Pelletron Accelerator at Mumbai delivers MeV energies of heavy ions for research in basic as well as applied sciences. Heavy ions of various species and energies from BARC-TIFR Pelletron Accelerator were used to make TEMs using polyethylene terephthalate (PET/Mylar) films of 25 micron thickness. The films used were procured from reputed manufactures in India

  11. The Use and Abuse of Limits of Detection in Environmental Analytical Chemistry

    Directory of Open Access Journals (Sweden)

    Richard J. C. Brown

    2008-01-01

    Full Text Available The limit of detection (LoD serves as an important method performance measure that is useful for the comparison of measurement techniques and the assessment of likely signal to noise performance, especially in environmental analytical chemistry. However, the LoD is only truly related to the precision characteristics of the analytical instrument employed for the analysis and the content of analyte in the blank sample. This article discusses how other criteria, such as sampling volume, can serve to distort the quoted LoD artificially and make comparison between various analytical methods inequitable. In order to compare LoDs between methods properly, it is necessary to state clearly all of the input parameters relating to the measurements that have been used in the calculation of the LoD. Additionally, the article discusses that the use of LoDs in contexts other than the comparison of the attributes of analytical methods, in particular when reporting analytical results, may be confusing, less informative than quoting the actual result with an accompanying statement of uncertainty, and may act to bias descriptive statistics.

  12. Correlation of simulated TEM images with irradiation induced damage

    International Nuclear Information System (INIS)

    Schaeublin, R.; Almeida, P. de; Almazouzi, A.; Victoria, M.

    2000-01-01

    Crystal damage induced by irradiation is investigated using transmission electron microscopy (TEM) coupled to molecular dynamics (MD) calculations. The displacement cascades are simulated for energies ranging from 10 to 50 keV in Al, Ni and Cu and for times of up to a few tens of picoseconds. Samples are then used to perform simulations of the TEM images that one could observe experimentally. Diffraction contrast is simulated using a method based on the multislice technique. It appears that the cascade induced damage in Al imaged in weak beam exhibits little contrast, which is too low to be experimentally visible, while in Ni and Cu a good contrast is observed. The number of visible clusters is always lower than the actual one. Conversely, high resolution TEM (HRTEM) imaging allows most of the defects contained in the sample to be observed, although experimental difficulties arise due to the low contrast intensity of the smallest defects. Single point defects give rise in HTREM to a contrast that is similar to that of cavities. TEM imaging of the defects is discussed in relation to the actual size of the defects and to the number of clusters deduced from MD simulations

  13. Analytical TEM of service-induced SCC in alloy 600TT steam generator tubing

    International Nuclear Information System (INIS)

    Wolfe, R.; Legras, L.; Boccanfuso; Martin, A.

    2015-01-01

    In 2008, Vogtle Electric Generating Plant Unit 1 performed tube pulls to confirm outside diameter stress corrosion cracking (ODSCC) in a steam generator with thermally treated Alloy 600TT tubing. Subsequent metallographic and other laboratory work attributed the cracking to the non-optimal microstructure of the tubing and the elevated residual stresses at the expansion transition. In the current work, analytical transmission electron microscopy was performed to gain a better understanding of this in-service cracking through a detailed characterization of the oxides and crack tips. These examinations, which are the first of this kind for U.S. Alloy 600TT tubing service cracks, detected lead (Pb) in the region of the top-of-tube sheet crevice, in oxides at the crack tips, and at degraded grain boundaries. In addition, sulfur was observed in oxides on the outside surface of the tube in the free span area. The presence of Pb at the crack tip and the lack of plasticity on the observed failure surfaces suggest that the environment played a predominant role in the cracking of this tubing with a non-optimal microstructure. The significance of the degradation will be discussed in the context of overall corrosion indications in Alloy 600TT steam generators in the United States. (authors)

  14. TEM examination of the effect of post-irradiation annealing on 7.7 dpa AISI 304 stainless steel

    International Nuclear Information System (INIS)

    Karlsen, W.; Ivanchenko, M.; Pakarinen, J.; Karlsen, T.

    2015-01-01

    Stainless steels exposed to neutron irradiation during service in light water reactors (LWR) can become susceptible to intergranular cracking, referred to as irradiation assisted stress corrosion cracking (IASCC). Analytical transmission electron microscopy (ATEM) was used to examine the effect of post-irradiation annealing (PIA) on radiation-induced segregation (RIS) at the grain boundaries of 7.7 dpa AISI 304 stainless steel. The grain boundary profiles and the irradiation damage were analysed in the as-irradiated state and after PIA of 6 hours at 500 C. degrees and after 25 hours at 500 C. degrees and 550 C. degrees by using transmission electron microscopy (TEM). As a main conclusion from the TEM examinations, the effects of PIA were found to be relatively small after only 6 hours, while after 25 hours of PIA at both 500 and 550 C. degrees, RIS was almost recovered and only marginal deviation in chemical composition could be found near the GB. The as-irradiated state showed extreme RIS values of Si 4.9 wt%, Cr 14.7 wt%, Ni 23.4 wt%, and P 1.4 wt%., while upon PIA for 6 hours the extreme values for RIS were Si 3.9 wt%, Cr 16.0 wt%, Ni 21 wt%, and P 0.9 wt%. After 6 hours annealing at 500 C. dislocation loops start to grow, while dislocation density remains of the same order of magnitude. After annealing for 25 hours at 500 C. degrees the average size of dislocation loops remains nearly the same, while dislocation density was reduced almost by one fold. In the areas where dislocation density was found to be the lowest some features, which can most likely be attributed to stacking fault tetrahedral (SFT) were found. Annealing at even higher temperature (550 C.) affected the average size of the dislocation loops, making them almost twice as large as well as resulting in a very broad distribution of dislocation sizes. Density of dislocations is also reduced by one fold in comparison to the as irradiated condition and leads to formation of SFTs, which could be

  15. Qualidade de vida do paciente submetido à Microcirurgia Endoscópica Transanal (TEM Quality of life after Transanal Endoscopic Microsurgery (TEM

    Directory of Open Access Journals (Sweden)

    Roberto da Silveira Moraes

    2007-03-01

    Full Text Available RACIONAL: A Microcirurgia Endoscópica Transanal (TEM é procedimento minimamente invasivo para o tratamento de tumores retais selecionados. Atualmente, existe crescente interesse médico na medida quantitativa da qualidade de vida. OBJETIVO: Avaliar a qualidade de vida dos pacientes submetidos a TEM no Serviço de Cirurgia do Aparelho Digestivo no Hospital de Clínicas da Universidade Federal do Paraná. MÉTODOS: Trata-se de um estudo observacional prospectivo e de coorte da avaliação da qualidade de vida após TEM. Trinta e quatro pacientes responderam a um questionário composto de 14 questões, abordando aspectos pós-operatórios e laborais. Dirigiam-se elas para levantar dados principalmente sobre: o consentimento informado; a dor experimentada após a operação; a capacidade de o paciente caminhar no período pós-operatório; o período para retorno às atividades habituais; a satisfação com a ausência de cicatriz pós-operatória; a incontinência no pós-operatório; se recomendaria a operação a um familiar ou conhecido. RESULTADOS: Todos os 34 pacientes relataram ter sido adequadamente informados sobre o procedimento. Ausência de dor pós-operatória foi observada em 82,5% e todos se mostraram capazes de deambular no 1º dia do pós-operatório. O retorno às atividades habituais deu-se em média sete dias após o procedimento. Somente cinco pacientes (14,70% apresentaram incontinência fecal transitória, não maior que uma semana. Três pacientes (8,82% necessitaram de re-internação, sendo dois por tumores residuais e outro por recidiva tumoral. Dois pacientes (5,88% referiram modificação temporária na vida sexual após a cirurgia e 97,05% indicariam a TEM a um familiar ou amigo. O período médio de internação foi de três dias. CONCLUSÃO: Os pacientes apresentaram boa evolução, com pouca dor pós-operatória, curto período de internação e baixo índice de complicações, mostrando satisfação e adequada

  16. Analytical method comparisons for the accurate determination of PCBs in sediments

    Energy Technology Data Exchange (ETDEWEB)

    Numata, M.; Yarita, T.; Aoyagi, Y.; Yamazaki, M.; Takatsu, A. [National Metrology Institute of Japan, Tsukuba (Japan)

    2004-09-15

    National Metrology Institute of Japan in National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) has been developing several matrix reference materials, for example, sediments, water and biological tissues, for the determinations of heavy metals and organometallic compounds. The matrix compositions of those certified reference materials (CRMs) are similar to compositions of actual samples, and those are useful for validating analytical procedures. ''Primary methods of measurements'' are essential to obtain accurate and SI-traceable certified values in the reference materials, because the methods have the highest quality of measurement. However, inappropriate analytical operations, such as incomplete extraction of analytes or crosscontamination during analytical procedures, will cause error of analytical results, even if one of the primary methods, isotope-dilution, is utilized. To avoid possible procedural bias for the certification of reference materials, we employ more than two analytical methods which have been optimized beforehand. Because the accurate determination of trace POPs in the environment is important to evaluate their risk, reliable CRMs are required by environmental chemists. Therefore, we have also been preparing matrix CRMs for the determination of POPs. To establish accurate analytical procedures for the certification of POPs, extraction is one of the critical steps as described above. In general, conventional extraction techniques for the determination of POPs, such as Soxhlet extraction (SOX) and saponification (SAP), have been characterized well, and introduced as official methods for environmental analysis. On the other hand, emerging techniques, such as microwave-assisted extraction (MAE), pressurized fluid extraction (PFE) and supercritical fluid extraction (SFE), give higher recovery yields of analytes with relatively short extraction time and small amount of solvent, by reasons of the high

  17. Selecting analytical tools for characterization of polymersomes in aqueous solution

    DEFF Research Database (Denmark)

    Habel, Joachim Erich Otto; Ogbonna, Anayo; Larsen, Nanna

    2015-01-01

    Selecting the appropriate analytical methods for characterizing the assembly and morphology of polymer-based vesicles, or polymersomes are required to reach their full potential in biotechnology. This work presents and compares 17 different techniques for their ability to adequately report size....../purification. Of the analytical methods tested, Cryo-transmission electron microscopy and atomic force microscopy (AFM) turned out to be advantageous for polymersomes with smaller diameter than 200 nm, whereas confocal microscopy is ideal for diameters >400 nm. Polymersomes in the intermediate diameter range can be characterized...... using freeze fracture Cryo-scanning electron microscopy (FF-Cryo-SEM) and nanoparticle tracking analysis (NTA). Small angle X-ray scattering (SAXS) provides reliable data on bilayer thickness and internal structure, Cryo-TEM on multilamellarity. Taken together, these tools are valuable...

  18. Pyrrolizidine alkaloids in honey: comparison of analytical methods.

    Science.gov (United States)

    Kempf, M; Wittig, M; Reinhard, A; von der Ohe, K; Blacquière, T; Raezke, K-P; Michel, R; Schreier, P; Beuerle, T

    2011-03-01

    Pyrrolizidine alkaloids (PAs) are a structurally diverse group of toxicologically relevant secondary plant metabolites. Currently, two analytical methods are used to determine PA content in honey. To achieve reasonably high sensitivity and selectivity, mass spectrometry detection is demanded. One method is an HPLC-ESI-MS-MS approach, the other a sum parameter method utilising HRGC-EI-MS operated in the selected ion monitoring mode (SIM). To date, no fully validated or standardised method exists to measure the PA content in honey. To establish an LC-MS method, several hundred standard pollen analysis results of raw honey were analysed. Possible PA plants were identified and typical commercially available marker PA-N-oxides (PANOs). Three distinct honey sets were analysed with both methods. Set A consisted of pure Echium honey (61-80% Echium pollen). Echium is an attractive bee plant. It is quite common in all temperate zones worldwide and is one of the major reasons for PA contamination in honey. Although only echimidine/echimidine-N-oxide were available as reference for the LC-MS target approach, the results for both analytical techniques matched very well (n = 8; PA content ranging from 311 to 520 µg kg(-1)). The second batch (B) consisted of a set of randomly picked raw honeys, mostly originating from Eupatorium spp. (0-15%), another common PA plant, usually characterised by the occurrence of lycopsamine-type PA. Again, the results showed good consistency in terms of PA-positive samples and quantification results (n = 8; ranging from 0 to 625 µg kg(-1) retronecine equivalents). The last set (C) was obtained by consciously placing beehives in areas with a high abundance of Jacobaea vulgaris (ragwort) from the Veluwe region (the Netherlands). J. vulgaris increasingly invades countrysides in Central Europe, especially areas with reduced farming or sites with natural restorations. Honey from two seasons (2007 and 2008) was sampled. While only trace amounts of

  19. Razvijmo sebe, druge in s tem svoj kraj

    Directory of Open Access Journals (Sweden)

    Dušana Findeisen

    1997-12-01

    Full Text Available Dušana Findeisen v tem prispevku obravnava vprašanje, kako spodbuditi ljudi k soodgovornosti za lasten razvoj in razvoj kraja. Preučuje tudi, kako naj prebivalci postanejo soodgovorni za zadostitev lastnih potreb in potreb njihovega kraja. V zvezi s tem se dotakne vloge izobraževalca odraslih - animatorja lokalnih projektov. Poudarja tudi pomen navezovanja novih odnosov in razmerij med lokalnimi skupnostmi in državo ter uvajanje “strukturalne politike”, kot jo imenuje avtorica, za sistemsko pomoč razvoju lokalnih projektov. Nazadnje pa obravnava vlogo lokalnih projektov z vidika razvoja kraja.

  20. Establishment of in situ TEM-implanter/accelerator interface facility at Wuhan University

    International Nuclear Information System (INIS)

    Guo, L.P.; Liu, C.S.; Li, M.; Song, B.; Ye, M.S.; Fu, D.J.; Fan, X.J.

    2008-01-01

    In order to perform in situ investigations on the evolution of microstructures during ion irradiation for the evaluation of irradiation-resistance performance of advanced materials, we have established a transmission electron microscope (TEM)-implanter/accelerator interface facility at Wuhan University, the first of its kind in China. A Hitachi H800 TEM was linked to a 200 kV ion implanter and a 2x1.7 MV tandem accelerator through the interface system designed on the basis of ion beam transportation calculations. Effective steps were taken to isolate the TEM from mechanical vibration transmitted from the ion beam lines, and no significant degradation of microscope resolution was observed when the TEM operated under high zoom modes during the ion implantation. In the test experiments, ion beams of N + , He + , Ar + , and H + were successfully transported from the implanter into the TEM chamber through the interface system, and the ion currents measured at the entrance of the TEM column were between 20 and 80 nA. The amorphisation process of Si crystal irradiated by N + ion beams was successfully observed in the preliminary experiments, demonstrating that this interface facility is capable of in situ study of ion irradiated samples

  1. Laser Based In Situ Techniques: Novel Methods for Generating Extreme Conditions in TEM Samples

    Energy Technology Data Exchange (ETDEWEB)

    Taheri, M; Lagrange, T; Reed, B; Armstrong, M; Campbell, G; DeHope, W; Kim, J; King, W; Masiel, D; Browning, N

    2008-02-25

    The Dynamic Transmission Electron Microscope (DTEM) is introduced as a novel tool for in situ processing of materials. Examples of various types of dynamic studies outline the advantages and differences of laser-based heating in the DTEM in comparison to conventional (resistive) heating in situ TEM methods. We demonstrate various unique capabilities of the drive laser, namely, in situ processing of nanoscale materials, rapid and high temperature phase transformations, and controlled thermal activation of materials. These experiments would otherwise be impossible without the use of the DTEM drive laser. Thus, the potential of the DTEM to as a new technique to process and characterize the growth of a myriad of micro and nanostructures is demonstrated.

  2. Quantitative phase imaging and differential interference contrast imaging for biological TEM

    International Nuclear Information System (INIS)

    Allman, B.E.; McMahon, P.J.; Barone-Nugent, E.D.; Nugent, E.D.

    2002-01-01

    Full text: Phase microscopy is a central technique in science. An experienced microscopist uses this effect to visualise (edge) structure within transparent samples by slightly defocusing the microscope. Although widespread in optical microscopy, phase contrast transmission electron microscopy (TEM) has not been widely adopted. TEM for biological specimens has largely relied on staining techniques to yield sufficient contrast. We show here a simple method for quantitative TEM phase microscopy that quantifies this phase contrast effect. Starting with conventional, digital, bright field images of the sample, our algorithm provides quantitative phase information independent of the sample's bright field intensity image. We present TEM phase images of a range of stained and unstained, biological and material science specimens. This independent phase and intensity information is then used to emulate a range of phase visualisation images familiar to optical microscopy, e.g. differential interference contrast. The phase images contain features not visible with the other imaging modalities. Further, if the TEM samples have been prepared on a microtome to a uniform thickness, the phase information can be converted into refractive index structure of the specimen. Copyright (2002) Australian Society for Electron Microscopy Inc

  3. Identification of proangiogenic TIE2-expressing monocytes (TEMs) in human peripheral blood and cancer.

    Science.gov (United States)

    Venneri, Mary Anna; De Palma, Michele; Ponzoni, Maurilio; Pucci, Ferdinando; Scielzo, Cristina; Zonari, Erika; Mazzieri, Roberta; Doglioni, Claudio; Naldini, Luigi

    2007-06-15

    Tumor-infiltrating myeloid cells, including tumor-associated macrophages (TAMs), have been implicated in tumor progression. We recently described a lineage of mouse monocytes characterized by expression of the Tie2 angiopoietin receptor and required for the vascularization and growth of several tumor models. Here, we report that TIE2 expression in human blood identifies a subset of monocytes distinct from classical inflammatory monocytes and comprised within the less abundant "resident" population. These TIE2-expressing monocytes (TEMs) accounted for 2% to 7% of blood mononuclear cells in healthy donors and were distinct from rare circulating endothelial cells and progenitors. In human cancer patients, TEMs were observed in the blood and, intriguingly, within the tumors, where they represented the main monocyte population distinct from TAMs. Conversely, TEMs were hardly detected in nonneoplastic tissues. In vitro, TEMs migrated toward angiopoietin-2, a TIE2 ligand released by activated endothelial cells and angiogenic vessels, suggesting a homing mechanism for TEMs to tumors. Purified human TEMs, but not TEM-depleted monocytes, markedly promoted angiogenesis in xenotransplanted human tumors, suggesting a potentially critical role of TEMs in human cancer progression. Human TEMs may provide a novel, biologically relevant marker of angiogenesis and represent a previously unrecognized target of cancer therapy.

  4. Correlating TEM images of damage in irradiated materials to molecular dynamics simulations

    International Nuclear Information System (INIS)

    Schaeublin, R.; Caturla, M.-J.; Wall, M.; Felter, T.; Fluss, M.; Wirth, B.D.; Diaz de la Rubia, T.; Victoria, M.

    2002-01-01

    TEM image simulations are used to couple the results from molecular dynamics (MD) simulations to experimental TEM images. In particular we apply this methodology to the study of defects produced during irradiation. MD simulations have shown that irradiation of FCC metals results in a population of vacancies and interstitials forming clusters. The limitation of these simulations is the short time scales available, on the order of 100 s of picoseconds. Extrapolation of the results from these short times to the time scales of the laboratory has been difficult. We address this problem by two methods: we perform TEM image simulations of MD simulations of cascades with an improved technique, to relate defects produced at short time scales with those observed experimentally at much longer time scales. On the other hand we perform in situ TEM experiments of Au irradiated at liquid-nitrogen temperatures, and study the evolution of the produced damage as the temperature is increased to room temperature. We find that some of the defects observed in the MD simulations at short time scales using the TEM image simulation technique have features that resemble those observed in laboratory TEM images of irradiated samples. In situ TEM shows that stacking fault tetrahedra are present at the lowest temperatures and are stable during annealing up to room temperature, while other defect clusters migrate one dimensionally above -100 deg. C. Results are presented here

  5. Analytical theory of intensity fluctuations in SASE

    Energy Technology Data Exchange (ETDEWEB)

    Yu, L.H.; Krinsky, S. [Brookhaven National Lab., Upton, NY (United States). National Synchrotron Light Source

    1997-07-01

    Recent advances in SASE experiments stimulate interest in quantitative comparison of measurements with theory. Extending the previous analysis of the SASE intensity in guided modes, the authors provide an analytical description of the intensity fluctuations by calculating intensity correlation functions in the frequency domain. Comparison of the results with experiment yields new insight into the SASE process.

  6. Benchmarking of a novel contactless characterisation method for micro thermoelectric modules (μTEMs)

    International Nuclear Information System (INIS)

    Hickey, S; Punch, J; Jeffers, N

    2014-01-01

    Significant challenges exist in the thermal control of Photonics Integrated Circuits (PICs) for use in optical communications. Increasing component density coupled with greater functionality is leading to higher device-level heat fluxes, stretching the capabilities of conventional cooling methods using thermoelectric modules (TEMs). A tailored thermal control solution incorporating micro thermoelectric modules (μTEMs) to individually address hotspots within PICs could provide an energy efficient alternative to existing control methods. Performance characterisation is required to establish the suitability of commercially-available μTEMs for the operating conditions in current and next generation PICs. The objective of this paper is to outline a novel method for the characterisation of thermoelectric modules (TEMs), which utilises infra-red (IR) heat transfer and temperature measurement to obviate the need for mechanical stress on the upper surface of low compression tolerance (∼0.5N) μTEMs. The method is benchmarked using a commercially-available macro scale TEM, comparing experimental data to the manufacturer's performance data sheet.

  7. Benchmarking of a novel contactless characterisation method for micro thermoelectric modules (μTEMs)

    Science.gov (United States)

    Hickey, S.; Punch, J.; Jeffers, N.

    2014-07-01

    Significant challenges exist in the thermal control of Photonics Integrated Circuits (PICs) for use in optical communications. Increasing component density coupled with greater functionality is leading to higher device-level heat fluxes, stretching the capabilities of conventional cooling methods using thermoelectric modules (TEMs). A tailored thermal control solution incorporating micro thermoelectric modules (μTEMs) to individually address hotspots within PICs could provide an energy efficient alternative to existing control methods. Performance characterisation is required to establish the suitability of commercially-available μTEMs for the operating conditions in current and next generation PICs. The objective of this paper is to outline a novel method for the characterisation of thermoelectric modules (TEMs), which utilises infra-red (IR) heat transfer and temperature measurement to obviate the need for mechanical stress on the upper surface of low compression tolerance (~0.5N) μTEMs. The method is benchmarked using a commercially-available macro scale TEM, comparing experimental data to the manufacturer's performance data sheet.

  8. Stereoscopic methods in TEM

    International Nuclear Information System (INIS)

    Thomas, L.E.

    1975-07-01

    Stereoscopic methods used in TEM are reviewed. The use of stereoscopy to characterize three-dimensional structures observed by TEM has become widespread since the introduction of instruments operating at 1 MV. In its emphasis on whole structures and thick specimens this approach differs significantly from conventional methods of microstructural analysis based on three-dimensional image reconstruction from a number of thin-section views. The great advantage of stereo derives from the ability to directly perceive and measure structures in three-dimensions by capitalizing on the unsurpassed human ability for stereoscopic matching of corresponding details on picture pairs showing the same features from different viewpoints. At this time, stereo methods are aimed mainly at structural understanding at the level of dislocations, precipitates, and irradiation-induced point-defect clusters in crystal and on the cellular irradiation-induced point-defect clusters in crystal and on the cellular level of biological specimens. 3-d reconstruction methods have concentrated on the molecular level where image resolution requirements dictate the use of very thin specimens. One recent application of three-dimensional coordinate measurements is a system developed for analyzing depth variations in the numbers, sizes and total volumes of voids produced near the surfaces of metal specimens during energetic ion bombardment. This system was used to correlate the void volumes at each depth along the ion range with the number of atomic displacements produced at that depth, thereby unfolding the entire swelling versus dose relationship from a single stereo view. A later version of this system incorporating computer-controlled stereo display capabilities is now being built

  9. Pyrrolizidine alkaloids in honey: comparison of analytical methods

    NARCIS (Netherlands)

    Kempf, M.; Wittig, M.; Reinhard, A.; Ohe, von der K.; Blacquière, T.; Raezke, K.P.; Michel, R.; Schreier, P.; Beuerle, T.

    2011-01-01

    Pyrrolizidine alkaloids (PAs) are a structurally diverse group of toxicologically relevant secondary plant metabolites. Currently, two analytical methods are used to determine PA content in honey. To achieve reasonably high sensitivity and selectivity, mass spectrometry detection is demanded. One

  10. OSCE vs. TEM: Different approaches to assess clinical skills of nursing students

    Directory of Open Access Journals (Sweden)

    Prasuna Jelly

    2017-01-01

    Full Text Available Introduction: Nurses are trained with specific clinical skills, and objective structured clinical examination (OSCE could be a better approach to assess clinical skills of nursing students. Materials and Methods: A comparative study was conducted by observational checklist regarding antenatal care and opinionnaire on the usefulness of OSCE and tradition evaluation method (TEM was used to assess the clinical skills and to get opinion. Results: The mean score of OSCE was more than TEM and the difference was statistically significant (P < 0.001. The opinion of students regarding the usefulness of OSCE was higher than TEM. Conclusions: The study concluded that implementing OSCE will overweigh the advantages of the TEM.

  11. Comparison between numeric and approximate analytic solutions for the prediction of soil metal uptake by roots. Example of cadmium.

    Science.gov (United States)

    Schneider, André; Lin, Zhongbing; Sterckeman, Thibault; Nguyen, Christophe

    2018-04-01

    The dissociation of metal complexes in the soil solution can increase the availability of metals for root uptake. When it is accounted for in models of bioavailability of soil metals, the number of partial differential equations (PDEs) increases and the computation time to numerically solve these equations may be problematic when a large number of simulations are required, for example for sensitivity analyses or when considering root architecture. This work presents analytical solutions for the set of PDEs describing the bioavailability of soil metals including the kinetics of complexation for three scenarios where the metal complex in solution was fully inert, fully labile, or partially labile. The analytical solutions are only valid i) at steady-state when the PDEs become ordinary differential equations, the transient phase being not covered, ii) when diffusion is the major mechanism of transport and therefore, when convection is negligible, iii) when there is no between-root competition. The formulation of the analytical solutions is for cylindrical geometry but the solutions rely on the spread of the depletion profile around the root, which was modelled assuming a planar geometry. The analytical solutions were evaluated by comparison with the corresponding PDEs for cadmium in the case of the French agricultural soils. Provided that convection was much lower than diffusion (Péclet's number<0.02), the cumulative uptakes calculated from the analytic solutions were in very good agreement with those calculated from the PDEs, even in the case of a partially labile complex. The analytic solutions can be used instead of the PDEs to predict root uptake of metals. The analytic solutions were also used to build an indicator of the contribution of a complex to the uptake of the metal by roots, which can be helpful to predict the effect of soluble organic matter on the bioavailability of soil metals. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. A comparison of two dose calculation algorithms-anisotropic analytical algorithm and Acuros XB-for radiation therapy planning of canine intranasal tumors.

    Science.gov (United States)

    Nagata, Koichi; Pethel, Timothy D

    2017-07-01

    Although anisotropic analytical algorithm (AAA) and Acuros XB (AXB) are both radiation dose calculation algorithms that take into account the heterogeneity within the radiation field, Acuros XB is inherently more accurate. The purpose of this retrospective method comparison study was to compare them and evaluate the dose discrepancy within the planning target volume (PTV). Radiation therapy (RT) plans of 11 dogs with intranasal tumors treated by radiation therapy at the University of Georgia were evaluated. All dogs were planned for intensity-modulated radiation therapy using nine coplanar X-ray beams that were equally spaced, then dose calculated with anisotropic analytical algorithm. The same plan with the same monitor units was then recalculated using Acuros XB for comparisons. Each dog's planning target volume was separated into air, bone, and tissue and evaluated. The mean dose to the planning target volume estimated by Acuros XB was 1.3% lower. It was 1.4% higher for air, 3.7% lower for bone, and 0.9% lower for tissue. The volume of planning target volume covered by the prescribed dose decreased by 21% when Acuros XB was used due to increased dose heterogeneity within the planning target volume. Anisotropic analytical algorithm relatively underestimates the dose heterogeneity and relatively overestimates the dose to the bone and tissue within the planning target volume for the radiation therapy planning of canine intranasal tumors. This can be clinically significant especially if the tumor cells are present within the bone, because it may result in relative underdosing of the tumor. © 2017 American College of Veterinary Radiology.

  13. SIMS and TEM study on oxide characteristics of Zircaloy

    International Nuclear Information System (INIS)

    Jung, Y. H.; Baek, J. H.; Kim, S. J.; Kim, K. H.; Choi, B. K.; Jung, Y. H.

    1998-01-01

    Long-term corrosion test, SIMS analysis, and TEM study were carried out to investigate the corrosion characteristics and corrosion mechanism of Zircaloy-4 in LiOH solution. The corrosion tests were performed in alkali solutions at 350 deg C for 500days. SIMS analysis was performed for the specimens prepared to have an equal oxide thickness to measure the cation content. TEM studies on the samples formed in various alkali solutions were also conducted. Based on the corrosion test, SIMS analysis, and TEM study, the cation is considered to control the corrosion in LiOH solution and its effect is dependent on the concentration of alkali and the oxide thickness. The slight acceleration of corrosion rate at a low concentration is thought to be caused by the cation incorporation into oxide while the significant acceleration at a high concentration is due to the transformation of oxide microstructure that would be induced by the cation incorporation

  14. A nonlinear filtering algorithm for denoising HR(S)TEM micrographs

    International Nuclear Information System (INIS)

    Du, Hongchu

    2015-01-01

    Noise reduction of micrographs is often an essential task in high resolution (scanning) transmission electron microscopy (HR(S)TEM) either for a higher visual quality or for a more accurate quantification. Since HR(S)TEM studies are often aimed at resolving periodic atomistic columns and their non-periodic deviation at defects, it is important to develop a noise reduction algorithm that can simultaneously handle both periodic and non-periodic features properly. In this work, a nonlinear filtering algorithm is developed based on widely used techniques of low-pass filter and Wiener filter, which can efficiently reduce noise without noticeable artifacts even in HR(S)TEM micrographs with contrast of variation of background and defects. The developed nonlinear filtering algorithm is particularly suitable for quantitative electron microscopy, and is also of great interest for beam sensitive samples, in situ analyses, and atomic resolution EFTEM. - Highlights: • A nonlinear filtering algorithm for denoising HR(S)TEM images is developed. • It can simultaneously handle both periodic and non-periodic features properly. • It is particularly suitable for quantitative electron microscopy. • It is of great interest for beam sensitive samples, in situ analyses, and atomic resolution EFTEM

  15. Quantitative Evaluation of Aged AISI 316L Stainless Steel Sensitization to Intergranular Corrosion: Comparison Between Microstructural Electrochemical and Analytical Methods

    Science.gov (United States)

    Sidhom, H.; Amadou, T.; Sahlaoui, H.; Braham, C.

    2007-06-01

    The evaluation of the degree of sensitization (DOS) to intergranular corrosion (IGC) of a commercial AISI 316L austenitic stainless steel aged at temperatures ranging from 550 °C to 800 °C during 100 to 80,000 hours was carried out using three different assessment methods. (1) The microstructural method coupled with the Strauss standard test (ASTM A262). This method establishes the kinetics of the precipitation phenomenon under different aging conditions, by transmission electronic microscope (TEM) examination of thin foils and electron diffraction. The subsequent chromium-depleted zones are characterized by X-ray microanalysis using scanning transmission electronic microscope (STEM). The superimposition of microstructural time-temperature-precipitation (TTP) and ASTM A262 time-temperature-sensitization (TTS) diagrams provides the relationship between aged microstructure and IGC. Moreover, by considering the chromium-depleted zone characteristics, sensitization and desensitization criteria could be established. (2) The electrochemical method involving the double loop-electrochemical potentiokinetic reactivation (DL-EPR) test. The operating conditions of this test were initially optimized using the experimental design method on the bases of the reliability, the selectivity, and the reproducibility of test responses for both annealed and sensitized steels. The TTS diagram of the AISI 316L stainless steel was established using this method. This diagram offers a quantitative assessment of the DOS and a possibility to appreciate the time-temperature equivalence of the IGC sensitization and desensitization. (3) The analytical method based on the chromium diffusion models. Using the IGC sensitization and desensitization criteria established by the microstructural method, numerical solving of the chromium diffusion equations leads to a calculated AISI 316L TTS diagram. Comparison of these three methods gives a clear advantage to the nondestructive DL-EPR test when it is

  16. HUMAN CAPSULE EPITHELIAL-CELL DEGENERATION A LM, SEM AND TEM INVESTIGATION

    NARCIS (Netherlands)

    JONGEBLOED, WL; KALICHARAN, D; WORST, JGF

    1993-01-01

    The degeneration of the capsule epithelium of cataractous lenses has been studied with LM, SEM on TEM with emphases on TEM. The observed degeneration of the epithelial cells can be described as follows: The cell nucleus becomes picnotic and desintegrates as result of change of the chromatin.

  17. Oxidation in ceria infiltrated metal supported SOFCs – A TEM investigation

    DEFF Research Database (Denmark)

    Knibbe, Ruth; Wang, Hsiang-Jen; Blennow Tullmar, Peter

    2013-01-01

    electron microscopy (TEM) techniques including energy-dispersive X-ray spectroscopy and electron energy-loss spectroscopy of focus ion beamed TEM samples. The infiltrated CGO is predominately converted into CeFeO3 after high temperature processing, protecting the alloy. A thin layer of Cr-oxide is observed...

  18. Selecting analytical tools for characterization of polymersomes in aqueous solution

    DEFF Research Database (Denmark)

    Habel, Joachim Erich Otto; Ogbonna, Anayo; Larsen, Nanna

    2015-01-01

    /purification. Of the analytical methods tested, Cryo-transmission electron microscopy and atomic force microscopy (AFM) turned out to be advantageous for polymersomes with smaller diameter than 200 nm, whereas confocal microscopy is ideal for diameters >400 nm. Polymersomes in the intermediate diameter range can be characterized...... using freeze fracture Cryo-scanning electron microscopy (FF-Cryo-SEM) and nanoparticle tracking analysis (NTA). Small angle X-ray scattering (SAXS) provides reliable data on bilayer thickness and internal structure, Cryo-TEM on multilamellarity. Taken together, these tools are valuable...

  19. A TEM Study on the Ti-Alloyed Grey Iron

    DEFF Research Database (Denmark)

    Moumeni, Elham; Tiedje, Niels Skat; Grumsen, Flemming Bjerg

    2014-01-01

    The microstructure of graphite flakes in titanium alloyed cast iron is studied using electron microscopy techniques. Dual beam SEM/FIB has been used for TEM sample preparation. A TEM study has been carried out on graphite flakes in grey cast iron using selected area electron diffraction. Based...... and that there is a high proportion of twins in the fine grained graphite. It appears that twinning and stacking faults are involved in the fine grained structure of the graphite. It is discussed how Ti addition affect crystal growth and may lead to formation of superfine graphite....

  20. Using ground-based geophysics to constrain the interpretation of airborne TEM data recorded across the Okavango Delta, Botswana

    Science.gov (United States)

    Podgorski, J. E.; Kalscheuer, T.; Doetsch, J.; Rabenstein, L.; Tshoso, G.; Meier, P.; Horstmeyer, H.; Kgotlhang, L.; Ploug, C.; Auken, E.; Kinzelbach, W. K.; Green, A. G.

    2011-12-01

    The Okavango Delta in northern Botswana is a near endorheic inland delta that has developed over the past ~2 MA in an active graben at the southwestern end of the East Africa Rift System. An annual flood from the north causes a slowly flowing surface water regime in the delta, but previous wetter climatic periods were responsible for intermittent lacustrine environments. The Okavango Delta is the largest permanent water body in the Kalahari Desert and, as such, represents an important resource for wildlife and humans alike. An airborne time-domain electromagnetic (TEM) survey, commissioned by the Botswana government, was undertaken in 2007 for the purpose of better understanding the hydrogeology of the delta. Initial processing and inversion of these data show within the main fan of the delta a resistive 20-50 m thick surface layer underlain by a 30-200 m thick conductive layer. In the upper fan, the conductive layer is underlain by a resistive unit beginning at about 150 m depth. This unit exhibits a dendritic pattern implying a fluvial origin. To help interpret this and other structures, geophysical field work was initiated in early 2011 at various locations in the delta. Seismic reflection and refraction, electrical resistive tomography (ERT), and ground TEM methods were employed. The seismic methods are useful for delineating the boundaries of the weathering and basement layers, whereas ERT provides an independent estimate of the resistivity structure, particularly at shallow depths. Ground TEM allows for a direct comparison with the airborne TEM soundings, helping to estimate the accuracy of the latter. Though still evolving, the current large-scale hydrogeological interpretation of the airborne data set includes a fresh water-saturated surface layer underlain by a saline aquifer and clay aquitard. In the upper fan of the delta, a fresh water aquifer appears to lie between the aquitard and the basement rock.

  1. In Situ TEM Creation of Nanowire Devices

    DEFF Research Database (Denmark)

    Alam, Sardar Bilal

    Integration of silicon nanowires (SiNWs) as active components in devices requires that desired mechanical, thermal and electrical interfaces can be established between the nanoscale geometry of the SiNW and the microscale architecture of the device. In situ transmission electron microscopy (TEM),...

  2. Delayed formation of chromosome aberrations in mouse pachytebne spermatocytes treated with triethylenemelamine (TEM)

    International Nuclear Information System (INIS)

    Generoso, W.M.; Krishna, M.; Sotomayor, R.E.; Cacheiro, N.L.A.

    1977-01-01

    Induction of chromosome aberrations in pachytene spermatocytes of mice by 2 mg/kg TEM was compared with induction by 400 R x rays. These doses induced comparably high dominant lethal effects in pachytene spermatocytes of mice. Cytological analysis at diakinesis-metaphase I stage showed that whereas 76.4% of the cells treated with x rays at pachytene stage had aberrations, the frequencies observed in two TEM experiments were only 0.8 and 2.2%. On the other hand, 5% of the progeny from TEM-treated pachytene spermatocytes were found to be translocation heterozygotes. This is the first report on the recovery of heritable translocations from treated spermatocytes of mice. The aberration frequencies observed for TEM in diakinesis-metaphase I were much too low to account for all the lethal mutations and heritable translocations. Thus, the formation of the bulk of aberrations induced by TEM in pachytene spermatocytes was delayed--a marked contrast to the more immediate formation of x-ray-induced aberrations. It is postulated that the formation of the bulk of TEM-induced aberrations in pachytene spermatocytes and in certain postmeiotic stages occurs sometime during spermiogenesis, and not through the operation of postfertilization pronuclear DNA synthesis

  3. Retained gas inventory comparison

    International Nuclear Information System (INIS)

    BARTON, W.B.

    1999-01-01

    Gas volume data derived from four different analytical methods were collected and analyzed for comparison to volumes originally used in the technical basis for the Basis for Interim Operations (BIO). The original volumes came from Hodgson (1996) listed in the reference section of this document. Hodgson (1996) screened all 177 single and double-shell tanks for the presence of trapped gas in waste via two analytical methods: Surface Level Rise (SLR), and Barometric Pressure Effect (BPE). More recent gas volume projections have been calculated using different analytical techniques along with updates to the parameters used as input to the SLR and BPE models. Gas volumes derived from new analytical instruments include those as measured by the Void Fraction Instrument (VFI) and Retained Gas Sampler (RGS). The results of this comparison demonstrate that the original retained gas volumes of Hodgson (1996) used as a technical basis in developing the BIO were conservative, and were conservative from a safety analysis standpoint. These results represent only comparisons to the original reported volumes using the limited set of newly acquired data that is available

  4. Geoelectrical characterization by joint inversion of VES/TEM in Paraná basin, Brazil

    Science.gov (United States)

    Bortolozo, C. A.; Couto, M. A.; Almeida, E. R.; Porsani, J. L.; Santos, F. M.

    2012-12-01

    For many years electrical (DC) and transient electromagnetic (TEM) soundings have been used in a great number of environmental, hydrological and mining exploration studies. The data of both methods are interpreted usually by individual 1D models resulting in many cases in ambiguous models. This can be explained by how the two different methodologies sample the subsurface. The vertical electrical sounding (VES) is good on marking very resistive structures, while the transient electromagnetic sounding (TEM) is very sensitive to map conductive structures. Another characteristic is that VES is more sensitive to shallow structures, while TEM soundings can reach deeper structures. A Matlab program for joint inversion of VES and TEM soundings, by using CRS algorithm was developed aiming explore the best of the both methods. Initially, the algorithm was tested with synthetic data and after it was used to invert experimental data from Paraná sedimentary basin. We present the results of a re-interpretation of 46 VES/TEM soundings data set acquired in Bebedouro region in São Paulo State - Brazil. The previous interpretation was based in geoelectrical models obtained by single inversion of the VES and TEM soundings. In this work we present the results with single inversion of VES and TEM sounding inverted by the Curupira Program and a new interpretation based in the joint inversion of both methodologies. The goal is increase the accuracy in determining the underground structures. As a result a new geoelectrical model of the region is obtained.

  5. Size Determination of Au Aerosol Nanoparticles by Off-Line TEM/STEM Observations

    Science.gov (United States)

    Karlsson, Lisa S.; Deppert, Knut; Malm, Jan-Olle

    2006-12-01

    Determination of particle size distributions of Au aerosol nanoparticles has been performed by a TEM/STEM investigation. The particles are generated by an evaporation/condensation method and are size-selected by differential mobility analyzers (DMA) based on their electrical mobility. Off-line TEM measurements resulted in equivalent projected area diameters assuming that the particles are spherical in shape. In this paper critical factors such as magnification calibration, sampling, image analysis, beam exposure and, particle shape are treated. The study shows that the measures of central tendency; mean, median and mode, are equal as expected from a narrow size distribution. Moreover, the correlation between TEM/STEM and DMA are good, in practice 1:1. Also, STEM has the advantage over TEM due to enhanced contrast and is proposed as an alternative route for determination of particle size distributions of nanoparticles with lower contrast.

  6. Size Determination of Au Aerosol Nanoparticles by Off-Line TEM/STEM Observations

    International Nuclear Information System (INIS)

    Karlsson, Lisa S.; Deppert, Knut; Malm, Jan-Olle

    2006-01-01

    Determination of particle size distributions of Au aerosol nanoparticles has been performed by a TEM/STEM investigation. The particles are generated by an evaporation/condensation method and are size-selected by differential mobility analyzers (DMA) based on their electrical mobility. Off-line TEM measurements resulted in equivalent projected area diameters assuming that the particles are spherical in shape. In this paper critical factors such as magnification calibration, sampling, image analysis, beam exposure and, particle shape are treated. The study shows that the measures of central tendency; mean, median and mode, are equal as expected from a narrow size distribution. Moreover, the correlation between TEM/STEM and DMA are good, in practice 1:1. Also, STEM has the advantage over TEM due to enhanced contrast and is proposed as an alternative route for determination of particle size distributions of nanoparticles with lower contrast

  7. Sample Preparation Methodologies for In Situ Liquid and Gaseous Cell Analytical Transmission Electron Microscopy of Electropolished Specimens.

    Science.gov (United States)

    Zhong, Xiang Li; Schilling, Sibylle; Zaluzec, Nestor J; Burke, M Grace

    2016-12-01

    In recent years, an increasing number of studies utilizing in situ liquid and/or gaseous cell scanning/transmission electron microscopy (S/TEM) have been reported. Because of the difficulty in the preparation of suitable specimens, these environmental S/TEM studies have been generally limited to studies of nanoscale structured materials such as nanoparticles, nanowires, or sputtered thin films. In this paper, we present two methodologies which have been developed to facilitate the preparation of electron-transparent samples from conventional bulk metals and alloys for in situ liquid/gaseous cell S/TEM experiments. These methods take advantage of combining sequential electrochemical jet polishing followed by focused ion beam extraction techniques to create large electron-transparent areas for site-specific observation. As an example, we illustrate the application of this methodology for the preparation of in situ specimens from a cold-rolled Type 304 austenitic stainless steel sample, which was subsequently examined in both 1 atm of air as well as fully immersed in a H2O environment in the S/TEM followed by hyperspectral imaging. These preparation techniques can be successfully applied as a general procedure for a wide range of metals and alloys, and are suitable for a variety of in situ analytical S/TEM studies in both aqueous and gaseous environments.

  8. Analytical solution to the hybrid diffusion-transport equation

    International Nuclear Information System (INIS)

    Nanneh, M.M.; Williams, M.M.R.

    1986-01-01

    A special integral equation was derived in previous work using a hybrid diffusion-transport theory method for calculating the flux distribution in slab lattices. In this paper an analytical solution of this equation has been carried out on a finite reactor lattice. The analytical results of disadvantage factors are shown to be accurate in comparison with the numerical results and accurate transport theory calculations. (author)

  9. TEM investigation of plant-irradiated NPP bolt material

    International Nuclear Information System (INIS)

    Pakarinen, J.; Ehrnsten, U.; Keinaenen, H.; Karlsen, W.; Karlsen, T.

    2015-01-01

    Analytical transmission electron microscopy (ATEM) was used to examine irradiation-induced damage in material removed from two different bolts from two different nuclear power plants. One section came from a French PWR, was made of CW AISI 316, and included a section of the bolt that had accumulated a dose of approximately 15 dpa during 19 operation cycles at 350 - 390 C. degrees. Another section came from a VVER bolt that was removed from the plant due to indications found in non-destructive examinations (NDE). The VVER bolt was made of solution annealed titanium stabilized 0X18H10T (corresponding to Type AISI 321) and had accumulated a fluence of 2.9 dpa. During the removal of that bolt, it was found that the bolt washer had been inappropriately spot welded to the shielding plate during assembly. Destructive investigations showed that the bolt had two large intergranular cracks, and the TEM samples were prepared from the material adjacent to those cracks. The PWR bolt had not failed, although cracks in the bolts with a similar history had been found previously. The fluence for the cold-worked AISI 316 PWR bolt was estimated to be about 15 dpa. Both the examined bolts showed a clear radiation induced segregation of alloying elements at the grain boundaries (GB-RIS), the presence of dislocation loops, the formation of precipitates, and linear deformation microstructures. Additionally, voids were found from the PWR bolt and the VVER bolt had a high density of dislocations. (authors)

  10. Laser-based analytical monitoring in nuclear-fuel processing plants

    International Nuclear Information System (INIS)

    Hohimer, J.P.

    1978-09-01

    The use of laser-based analytical methods in nuclear-fuel processing plants is considered. The species and locations for accountability, process control, and effluent control measurements in the Coprocessing, Thorex, and reference Purex fuel processing operations are identified and the conventional analytical methods used for these measurements are summarized. The laser analytical methods based upon Raman, absorption, fluorescence, and nonlinear spectroscopy are reviewed and evaluated for their use in fuel processing plants. After a comparison of the capabilities of the laser-based and conventional analytical methods, the promising areas of application of the laser-based methods in fuel processing plants are identified

  11. A Comparison of Key Concepts in Data Analytics and Data Science

    Science.gov (United States)

    McMaster, Kirby; Rague, Brian; Wolthuis, Stuart L.; Sambasivam, Samuel

    2018-01-01

    This research study provides an examination of the relatively new fields of Data Analytics and Data Science. We compare word rates in Data Analytics and Data Science documents to determine which concepts are mentioned most often. The most frequent concept in both fields is "data." The word rate for "data" is more than twice the…

  12. Analytic computation of average energy of neutrons inducing fission

    International Nuclear Information System (INIS)

    Clark, Alexander Rich

    2016-01-01

    The objective of this report is to describe how I analytically computed the average energy of neutrons that induce fission in the bare BeRP ball. The motivation of this report is to resolve a discrepancy between the average energy computed via the FMULT and F4/FM cards in MCNP6 by comparison to the analytic results.

  13. Evaluation methodology for comparing memory and communication of analytic processes in visual analytics

    Energy Technology Data Exchange (ETDEWEB)

    Ragan, Eric D [ORNL; Goodall, John R [ORNL

    2014-01-01

    Provenance tools can help capture and represent the history of analytic processes. In addition to supporting analytic performance, provenance tools can be used to support memory of the process and communication of the steps to others. Objective evaluation methods are needed to evaluate how well provenance tools support analyst s memory and communication of analytic processes. In this paper, we present several methods for the evaluation of process memory, and we discuss the advantages and limitations of each. We discuss methods for determining a baseline process for comparison, and we describe various methods that can be used to elicit process recall, step ordering, and time estimations. Additionally, we discuss methods for conducting quantitative and qualitative analyses of process memory. By organizing possible memory evaluation methods and providing a meta-analysis of the potential benefits and drawbacks of different approaches, this paper can inform study design and encourage objective evaluation of process memory and communication.

  14. Recent advances in cryo-TEM imaging of soft lipid nanoparticles

    DEFF Research Database (Denmark)

    Helvig, Shen Yu; Mat Azmi, Intan Diana Binti; Moghimi, Seyed Moien

    2015-01-01

    Cryo-transmission electron microscopy (Cryo-TEM), and its technological variations thereof, have become a powerful tool for detailed morphological characterization and 3D tomography of soft lipid and polymeric nanoparticles as well as biological materials such as viruses and DNA without chemical...... fixation. Here, we review and discuss recent advances in Cryo-TEM analysis of lipid-based drug nanocarriers with particular emphasis on morphological and internal nanostructure characterization of lyotropic liquid crystalline nanoparticles such as cubosomes and hexosomes....

  15. ANALISIS PARAMETER JARINGAN HSDPA KONDISI INDOOR DENGAN TEMS INVESTIGATION DAN G-NETTRACK PRO

    Directory of Open Access Journals (Sweden)

    Dewa Made Mahendra Yudha

    2016-03-01

    Full Text Available Penggunaan teknologi dalam sistem komunikasi bergerak sudah berkembang cukup pesat. Salah satu contohnya ada teknologi HSDPA. Pihak provider biasanya melakukan metode walk test untuk mengecek kekuatan sinyal dengan menggunakan software TEMS Investigtions. Dengan kemajuannya Teknologi walk test dapat diterapkan dengan lebih mudah yaitu menggunakan perangkat android yang sudah terinstal aplikasi G-Net track Pro. Pada penelitian ini, akan menggunakan tahapan sesuai alur yang ada pada metode penelitian yaitu dimulai dengan melakukan pengukuran berdasarkan jarak dengan membandingkan software TEMS Investigations dan G-NET TRACK PRO dengan parameter RSCP dan Ec/No. Setelah dilakukan pengukuran kemudian akan dilanjutkan dengan menganalisa antara hubungan parameter RSCP dan Ec/No menggunakan TEMS Investigations dan G-Net Pro. kemudian dilanjutkan menggunakan perhitungan teoritis parameter RSCP. Dari hasil pengukuran diproleh pada lantai I antena 1-1 pada titik jarak 5 meter parameter RSCP dengan TEMS Investigation memiliki nilai -75 dBm sedangkan dari G-Net Track Pro memiliki nilai -83 dBm. Pada parameter Ec/No dengan TEMS Investigation memiliki nilai -6 dB dan G_Net Track memiliki nilai -5 dB. Dapat disimpulkan bahwa aplikasi G-NetTrack Pro mampu menampilkan parameter yang dibutuhkan akan tetapi tidak sedetail TEMS investigation sehingga untuk proses pembelajaran dan pengenalan walk test aplikasi G-Net track Pro dapat digunakan.

  16. Determination of Morphological Parameters of Supported Gold Nanoparticles: Comparison of AFM Combined with Optical Spectroscopy and Theoretical Modeling versus TEM

    Directory of Open Access Journals (Sweden)

    Frank Hubenthal

    2012-07-01

    Full Text Available The morphology of small gold particles prepared by Volmer–Weber growth on sapphire substrates have been investigated by two different characterization techniques. First, by non-extensive atomic force microscopy (AFM in combination with optical spectroscopy and modeling of the optical properties using a theoretical model, recently developed in our group. Second, by extensive transmission electron microscopy (TEM. Comparing the results obtained with both techniques demonstrate that for small gold nanoparticles within the quasistatic limit, the morphological properties can be precisely determined by an appropriate theoretical modeling of the optical properties in combination with simple AFM measurements. The apparent mean axial ratio of the nanoparticles, i.e., the axial ratio that corresponds to the center frequency of the ensemble plasmon resonance, is obtained easily from the extinction spectrum. The mean size is determined by the nanoparticle number density and the amount of deposited material, measured by AFM and a quartz micro balance, respectively. To extract the most probable axial ratio of the nanoparticle ensemble, i.e., the axial ratio that corresponds to the most probable nanoparticle size in the ensemble, we apply the new theoretical model, which allows to extract the functional dependence of the nanoparticle shape on its size. The morphological parameters obtained with this procedure will be afterwards compared to extensive TEM measurements. The results obtained with both techniques yield excellent agreement. For example, the lateral dimensions of the nanoparticles after deposition of 15.2 × 1015 atoms/cm2 of gold has been compared. While a mean lateral diameter of (13 ± 2 nm has been extracted from AFM, optical spectroscopy and modeling, a value of (12 ± 2 nm is derived from TEM. The consistency of the results demonstrate the precision of our new model. Moreover, since our theoretical model allows to extract the functional

  17. In situ TEM observation of solid-gas reactions

    International Nuclear Information System (INIS)

    Kishita, K; Kamino, T; Watabe, A; Kuroda, K; Saka, H

    2008-01-01

    Under a gaseous atmosphere at high temperatures, almost all the materials (metal, catalysts, etc.) change their structures and properties. For the research and development of materials, it is of vital importance to clarify mechanisms of solid-gas and liquid-gas reactions. Recently an in situ TEM system combined with an environmental holder, which has a gas injection nozzle close to a specimen-heating element, has been developed. The gas injection nozzle permits gas to flow around the specimens sitting on the heating element made of a fine W filament. The newly developed in situ TEM has a differential pumping system; therefore, the pressure in the specimen chamber is maintained in the range of higher than 1 Pa, while the pressure in the electron gun chamber can be kept in the range of 10 -5 Pa. This system was applied to in situ observation of chemical reactions of metals with gases: Observation of oxidation and reduction under a gas pressure ranging from 10 -5 Pa to 1 Pa at high temperatures (room temperature to ∼1473 K) were successfully carried out on pure metal and rare metal catalysts at near-atomic resolution. This in situ environmental TEM system is promising for clarifying mechanisms of many solid-gas and liquid-gas reactions that take place at high temperatures under a gas atmosphere.

  18. Preparation of TEM specimen by cross-section technique

    International Nuclear Information System (INIS)

    Hamada, Shozo

    1986-01-01

    Transmission electron microscopy (TEM) is applied to the direct observation of the depth dependent damage structure in ion-irradiated stainless steel by using the cross-section technique; obtaining the TEM specimen from a slice of the irradiated stainless steel with thick Ni plating. Here has been developed the specimen preparation method of cross-section technique without heat treatment, which was necessary in the conventional method to strengthen the bonding between Ni and stainless steel. Nickel plating with good bonding to stainless steel is enabled by the following manner. First, the irradiated stainless steel is immersed in the Wood's nickel solution at room temperature for 60s to activate the surface, followed by the stricking for 300s at a current density of 300 A/m 2 in the solution to make fine and homogeneous nucleation of Ni on the stainless steel. Then, the sample is plated with Ni in the Watt's nickel plating solution at 333 K with current density of 900 ∼ 1,000 A/m 2 . The TEM disc is obtained by mechanical slicing from the specimen with Ni plating of more than 3 mm thickness. Electropolishing is accomplished by using both Ballmann method and jet electropolishing to perforate the disc accurately at the aimed point for the observation of the damage structure. (author)

  19. Evaluation of analytical reconstruction with a new gap-filling method in comparison to iterative reconstruction in [11C]-raclopride PET studies

    International Nuclear Information System (INIS)

    Tuna, U.; Johansson, J.; Ruotsalainen, U.

    2014-01-01

    The aim of the study was (1) to evaluate the reconstruction strategies with dynamic [ 11 C]-raclopride human positron emission tomography (PET) studies acquired from ECAT high-resolution research tomograph (HRRT) scanner and (2) to justify for the selected gap-filling method for analytical reconstruction with simulated phantom data. A new transradial bicubic interpolation method has been implemented to enable faster analytical 3D-reprojection (3DRP) reconstructions for the ECAT HRRT PET scanner data. The transradial bicubic interpolation method was compared to the other gap-filling methods visually and quantitatively using the numerical Shepp-Logan phantom. The performance of the analytical 3DRP reconstruction method with this new gap-filling method was evaluated in comparison with the iterative statistical methods: ordinary Poisson ordered subsets expectation maximization (OPOSEM) and resolution modeled OPOSEM methods. The image reconstruction strategies were evaluated using human data at different count statistics and consequently at different noise levels. In the assessments, 14 [ 11 C]-raclopride dynamic PET studies (test-retest studies of 7 healthy subjects) acquired from the HRRT PET scanner were used. Besides the visual comparisons of the methods, we performed regional quantitative evaluations over the cerebellum, caudate and putamen structures. We compared the regional time-activity curves (TACs), areas under the TACs and binding potential (BP ND ) values. The results showed that the new gap-filling method preserves the linearity of the 3DRP method. Results with the 3DRP after gap-filling method exhibited hardly any dependency on the count statistics (noise levels) in the sinograms while we observed changes in the quantitative results with the EM-based methods for different noise contamination in the data. With this study, we showed that 3DRP with transradial bicubic gap-filling method is feasible for the reconstruction of high-resolution PET data with

  20. Analytic evaluation of LAMPF II Booster Cavity design

    International Nuclear Information System (INIS)

    Friedrichs, C.C.

    1985-01-01

    Through the past few decades, a great deal of sophistication has evolved in the numeric codes used to evaluate electromagnetically resonant structures. The numeric methods are extremely precise, even for complicated geometries, whereas analytic methods require a simple uniform geometry and a simple, known mode configuration if the same precision is to be obtained. The code SUPERFISH, which is near the present state-of-the-art of numeric methods, does have the following limitations: No circumferential geometry variations are permissible; there are no provisions for magnetic or dielectric losses; and finally, it is impractical (because of the complexity of the code) to modify it to extract particular bits of data one might want that are not provided by the code as written. This paper describes how SUPERFISH was used as an aid in derivating an analytic model of the LAMPF II Booster Cavity. Once a satisfactory model was derived, simple FORTRAN codes were generated to provide whatever data was required. The analytic model is made up of TEM- and radial-mode transmission-line sections, as well as lumped elements where appropriate. Radial transmission-line equations, which include losses, were not found in any literature, and the extension of the lossless equations to include magnetic and dielectric losses are included in this paper

  1. TEM-EELS: A personal perspective

    International Nuclear Information System (INIS)

    Egerton, R.F.

    2012-01-01

    The development of electron energy-loss spectroscopy in a transmission electron microscope (TEM-EELS) is illustrated through personal anecdote, highlighting some of the basic principles, instrumentation and personalities involved. The current state of the art is reviewed, together with some challenges for the future. -- Highlights: ► The history of EELS instrumentation is reviewed in a lighthearted manner. ► The current state of the art is summarized, together with some future possibilities. ► A couple of related mathematical puzzles are offered as a challenge to the reader.

  2. Minimum depth of investigation for grounded-wire TEM due to self-transients

    Science.gov (United States)

    Zhou, Nannan; Xue, Guoqiang

    2018-05-01

    The grounded-wire transient electromagnetic method (TEM) has been widely used for near-surface metalliferous prospecting, oil and gas exploration, and hydrogeological surveying in the subsurface. However, it is commonly observed that such TEM signal is contaminated by the self-transient process occurred at the early stage of data acquisition. Correspondingly, there exists a minimum depth of investigation, above which the observed signal is not applicable for reliable data processing and interpretation. Therefore, for achieving a more comprehensive understanding of the TEM method, it is necessary to perform research on the self-transient process and moreover develop an approach for quantifying the minimum detection depth. In this paper, we first analyze the temporal procedure of the equivalent circuit of the TEM method and present a theoretical equation for estimating the self-induction voltage based on the inductor of the transmitting wire. Then, numerical modeling is applied for building the relationship between the minimum depth of investigation and various properties, including resistivity of the earth, offset, and source length. It is guide for the design of survey parameters when the grounded-wire TEM is applied to the shallow detection. Finally, it is verified through applications to a coal field in China.

  3. Conservation through payments for an ecosys- tem service?

    African Journals Online (AJOL)

    tem service? In his Spotlights ... functions” and “ecosystem services” are being ridiculed by the developments in ... high price as legal marketing would avoid various middlemen. ... Diagnostic participatif de la gestion des ressources naturelles.

  4. Analytical chemistry of nuclear materials

    International Nuclear Information System (INIS)

    1963-01-01

    The last two decades have witnessed an enormous development in chemical analysis. The rapid progress of nuclear energy, of solid-state physics and of other fields of modern industry has extended the concept of purity to limits previously unthought of, and to reach the new dimensions of these extreme demands, entirely new techniques have been invented and applied and old ones have been refined. Recognizing these facts, the International Atomic Energy Agency convened a Panel on Analytical Chemistry of Nuclear Materials to discuss the general problems facing the analytical chemist engaged in nuclear energy development, particularly in newly developing centre and countries, to analyse the represent situation and to advise as to the directions in which research and development appear to be most necessary. The Panel also discussed the analytical programme of the Agency's laboratory at Seibersdorf, where the Agency has already started a programme of international comparison of analytical methods which may lead to the establishment of international standards for many materials of interest. Refs and tabs

  5. Test for English Majors (TEM) in China

    Science.gov (United States)

    Jin, Yan; Fan, Jinsong

    2011-01-01

    The purpose of the Test for English Majors (TEM) is to measure the English proficiency of Chinese university undergraduates majoring in English Language and Literature and to examine whether these students meet the required levels of English language abilities as specified in the National College English Teaching Syllabus for English Majors…

  6. Automated SEM and TEM sample preparation applied to copper/low k materials

    Science.gov (United States)

    Reyes, R.; Shaapur, F.; Griffiths, D.; Diebold, A. C.; Foran, B.; Raz, E.

    2001-01-01

    We describe the use of automated microcleaving for preparation of both SEM and TEM samples as done by SELA's new MC500 and TEMstation tools. The MC500 is an automated microcleaving tool that is capable of producing cleaves with 0.25 μm accuracy resulting in SEM-ready samples. The TEMstation is capable of taking a sample output from the MC500 (or from SELA's earlier MC200 tool) and producing a FIB ready slice of 25±5 μm, mounted on a TEM-washer and ready for FIB thinning to electron transparency for TEM analysis. The materials selected for the tool set evaluation mainly included the Cu/TaN/HOSP low-k system. The paper is divided into three sections, experimental approach, SEM preparation and analysis of HOSP low-k, and TEM preparation and analysis of Cu/TaN/HOSP low-k samples. For the samples discussed, data is presented to show the quality of preparation provided by these new automated tools.

  7. Analysis of plant gums and saccharide materials in paint samples: comparison of GC-MS analytical procedures and databases.

    Science.gov (United States)

    Lluveras-Tenorio, Anna; Mazurek, Joy; Restivo, Annalaura; Colombini, Maria Perla; Bonaduce, Ilaria

    2012-10-10

    Saccharide materials have been used for centuries as binding media, to paint, write and illuminate manuscripts and to apply metallic leaf decorations. Although the technical literature often reports on the use of plant gums as binders, actually several other saccharide materials can be encountered in paint samples, not only as major binders, but also as additives. In the literature, there are a variety of analytical procedures that utilize GC-MS to characterize saccharide materials in paint samples, however the chromatographic profiles are often extremely different and it is impossible to compare them and reliably identify the paint binder. This paper presents a comparison between two different analytical procedures based on GC-MS for the analysis of saccharide materials in works-of-art. The research presented here evaluates the influence of the analytical procedure used, and how it impacts the sugar profiles obtained from the analysis of paint samples that contain saccharide materials. The procedures have been developed, optimised and systematically used to characterise plant gums at the Getty Conservation Institute in Los Angeles, USA (GCI) and the Department of Chemistry and Industrial Chemistry of the University of Pisa, Italy (DCCI). The main steps of the analytical procedures and their optimisation are discussed. The results presented highlight that the two methods give comparable sugar profiles, whether the samples analysed are simple raw materials, pigmented and unpigmented paint replicas, or paint samples collected from hundreds of centuries old polychrome art objects. A common database of sugar profiles of reference materials commonly found in paint samples was thus compiled. The database presents data also from those materials that only contain a minor saccharide fraction. This database highlights how many sources of saccharides can be found in a paint sample, representing an important step forward in the problem of identifying polysaccharide binders in

  8. TEM in situ cube-corner indentation analysis using ViBe motion detection algorithm

    Science.gov (United States)

    Yano, K. H.; Thomas, S.; Swenson, M. J.; Lu, Y.; Wharry, J. P.

    2018-04-01

    Transmission electron microscopic (TEM) in situ mechanical testing is a promising method for understanding plasticity in shallow ion irradiated layers and other volume-limited materials. One of the simplest TEM in situ experiments is cube-corner indentation of a lamella, but the subsequent analysis and interpretation of the experiment is challenging, especially in engineering materials with complex microstructures. In this work, we: (a) develop MicroViBE, a motion detection and background subtraction-based post-processing approach, and (b) demonstrate the ability of MicroViBe, in combination with post-mortem TEM imaging, to carry out an unbiased qualitative interpretation of TEM indentation videos. We focus this work around a Fe-9%Cr oxide dispersion strengthened (ODS) alloy, irradiated with Fe2+ ions to 3 dpa at 500 °C. MicroViBe identifies changes in Laue contrast that are induced by the indentation; these changes accumulate throughout the mechanical loading to generate a "heatmap" of features in the original TEM video that change the most during the loading. Dislocation loops with b = ½ identified by post-mortem scanning TEM (STEM) imaging correspond to hotspots on the heatmap, whereas positions of dislocation loops with b = do not correspond to hotspots. Further, MicroViBe enables consistent, objective quantitative approximation of the b = ½ dislocation loop number density.

  9. Performance Comparison of Big Data Analytics With NEXUS and Giovanni

    Science.gov (United States)

    Jacob, J. C.; Huang, T.; Lynnes, C.

    2016-12-01

    NEXUS is an emerging data-intensive analysis framework developed with a new approach for handling science data that enables large-scale data analysis. It is available through open source. We compare performance of NEXUS and Giovanni for 3 statistics algorithms applied to NASA datasets. Giovanni is a statistics web service at NASA Distributed Active Archive Centers (DAACs). NEXUS is a cloud-computing environment developed at JPL and built on Apache Solr, Cassandra, and Spark. We compute global time-averaged map, correlation map, and area-averaged time series. The first two algorithms average over time to produce a value for each pixel in a 2-D map. The third algorithm averages spatially to produce a single value for each time step. This talk is our report on benchmark comparison findings that indicate 15x speedup with NEXUS over Giovanni to compute area-averaged time series of daily precipitation rate for the Tropical Rainfall Measuring Mission (TRMM with 0.25 degree spatial resolution) for the Continental United States over 14 years (2000-2014) with 64-way parallelism and 545 tiles per granule. 16-way parallelism with 16 tiles per granule worked best with NEXUS for computing an 18-year (1998-2015) TRMM daily precipitation global time averaged map (2.5 times speedup) and 18-year global map of correlation between TRMM daily precipitation and TRMM real time daily precipitation (7x speedup). These and other benchmark results will be presented along with key lessons learned in applying the NEXUS tiling approach to big data analytics in the cloud.

  10. Pilot production of track etch membranes (TEMS) using heavy ion beam scanner

    International Nuclear Information System (INIS)

    Nair, J.P.; Surendran, P.; Sparrow, Hillary; Ninawe, N.G.; Bhagwat, P.V.; Acharya, N.; Kulshreshta, V.; Rajesh Kumar; Vijay, Y.K.; Kurup, M.B.

    2005-01-01

    Various methods for making TEMs were conducted at Pelletron Accelerator Facility. The technique for production using ion beam scattering was also established. This is an effort to make TEMs on pilot basis at BARC- TIFR Pelletron Accelerator using Heavy Ion Beam Scanner till large rolling mechanism is implemented

  11. In situ mechanical TEM: seeing and measuring under stress with electrons

    International Nuclear Information System (INIS)

    Legros, M.

    2014-01-01

    From the first observation of moving dislocations in 1956 to the latest developments of piezo-actuated sample holders and direct electron sensing cameras in modern transmission electron microscopes (TEM), in situ mechanical testing has brought an unequaled view of the involved mechanisms during the plastic deformation of materials. Although MEMS-based or load-cell equipped holders provide an almost direct measure of these quantities, deriving stress and strain from in situ TEM experiments has an extensive history. Nowadays, the realization of a complete mechanical test while observing the evolution of a dislocation structure is possible, and it constitutes the perfect combination to explore size effects in plasticity. New cameras, data acquisition rates and intrinsic image-related techniques, such as holography, should extend the efficiency and capabilities of in situ deformation inside a TEM. (author)

  12. Tie2-expressing monocytes (TEMs): novel targets and vehicles of anticancer therapy?

    Science.gov (United States)

    De Palma, Michele; Naldini, Luigi

    2009-08-01

    There is a growing interest in understanding the complex interactions between bone marrow-derived myeloid-lineage cells and angiogenesis in tumors. Such interest has been revived recently by the observation that tumor-infiltrating myeloid cells convey proangiogenic programs that can counteract the activity of antiangiogenic drugs in mouse tumor models. Among myeloid cells, Tie2-expressing monocytes (TEMs) appear to have nonredundant function in promoting tumor angiogenesis and growth in mouse models. The identification and functional characterization of TEMs in mice and humans may provide novel molecular targets for anticancer therapy. Moreover, TEMs may be exploited to deliver antitumor drugs specifically to the tumor microenvironment.

  13. U-Zr alloy: XPS and TEM study of surface passivation

    Science.gov (United States)

    Paukov, M.; Tkach, I.; Huber, F.; Gouder, T.; Cieslar, M.; Drozdenko, D.; Minarik, P.; Havela, L.

    2018-05-01

    Surface reactivity of Uranium metal is an important factor limiting its practical applications. Bcc alloys of U with various transition metals are much less reactive than pure Uranium. So as to specify the mechanism of surface protection, we have been studying the U-20 at.% Zr alloy by photoelectron spectroscopy and transmission electron microscopy. The surface was studied in as-obtained state, in various stages of surface cleaning, and during an isochronal annealing cycle. The analysis based on U-4f, Zr-3p, and O-1 s spectra shows that a Zr-rich phase segregates at the surface at temperatures exceeding 550 K, which provides a self-assembled coating. The comparison of oxygen exposure of the stoichiometric and coated surfaces shows that the coating is efficiently preventing the oxidation of uranium even at elevated temperatures. The coating can be associated with the UZr2+x phase. TEM study indicated that the coating is about 20 nm thick. For the clean state, the U-4f core-level lines of the bcc alloy are practically identical to those of α-U, revealing similar delocalization of the 5f electronic states.

  14. An efficient and reproducible process for transmission electron microscopy (TEM) of rare cell populations

    Science.gov (United States)

    Kumar, Sachin; Ciraolo, Georgianne; Hinge, Ashwini; Filippi, Marie-Dominique

    2014-01-01

    Transmission electron microscopy (TEM) provides ultra-structural details of cells at the sub-organelle level. However, details of the cellular ultrastructure, and the cellular organization and content of various organelles in rare populations, particularly in the suspension, like hematopoietic stem cells (HSCs) remained elusive. This is mainly due to the requirement of millions of cells for TEM studies. Thus, there is a vital requirement of a method that will allow TEM studies with low cell numbers of such rare populations. We describe an alternative and novel approach for TEM studies for rare cell populations. Here we performed TEM study from 10,000 HSC cells with quite ease. In particular, tiny cell pellets were identified by Evans blue staining after PFA-GA fixation. The cell pellet was pre-embedded in agarose in a small microcentrifuge tube and processed for dehydration, infiltration and embedding. Semi-thin and ultra-thin sections identified clusters of numerous cells per sections with well preserved morphology and ultrastructural details of golgi complex and mitochondria. Together, this method provides an efficient, easy and reproducible process to perform qualitative and quantitative TEM analysis from limited biological samples including cells in suspension. PMID:24291346

  15. Analytical capabilities of laser-probe mass spectrometry

    International Nuclear Information System (INIS)

    Kovalev, I.D.; Madsimov, G.A.; Suchkov, A.I.; Larin, N.V.

    1978-01-01

    The physical bases and quantitative analytical procedures of laser-probe mass spectrometry are considered in this review. A comparison is made of the capabilities of static and dynamic mass spectrometers. Techniques are studied for improving the analytical characteristics of laser-probe mass spectrometers. The advantages, for quantitative analysis, of the Q-switched mode over the normal pulse mode for lasers are: (a) the possibility of analysing metals, semiconductors and insulators without the use of standards; and (b) the possibility of layer-by-layer and local analysis. (Auth.)

  16. Comparison between energy dispersive X-ray fluorescence and other nuclear analytical techniques in mineral exploration and mining

    International Nuclear Information System (INIS)

    Clayton, C.G.; Packer, T.W.; Wormald, M.R.

    1979-01-01

    At the present time there is an increasing awareness of the value and need for in-situ analytical methods throughout the general area of mineral exploration and mining. Of the alternative techniques, the measurement of natural gamma radiation is well established for uranium exploration and it is now being developed for sea-bed and lake-bed surveying. Energy dispersive X-ray fluorescence equipment is becoming more generally accepted, especially for mine control. Neutron techniques, for so long used routinely in oil well logging, are now being developed for a wide range of applications in all aspects of exploration and mining. It is believed that these techniques will result in major applications in the future. The present paper compares the principal characteristics of energy dispersive X-ray fluorescence and neutron techniques in particular, with special emphasis being given to those factors which affect the accuracy of analytical content; such as elemental resolution, matrix effects, material heterogeneity and neutron transport. A generalised comparison between the techniques is difficult to achieve because of the different nature of radiation interactions, but a range of applications is described and these show the complementary nature of the methods and point to the areas for more active development in the future. (author)

  17. VES/TEM 1D joint inversion by using Controlled Random Search (CRS) algorithm

    Science.gov (United States)

    Bortolozo, Cassiano Antonio; Porsani, Jorge Luís; Santos, Fernando Acácio Monteiro dos; Almeida, Emerson Rodrigo

    2015-01-01

    Electrical (DC) and Transient Electromagnetic (TEM) soundings are used in a great number of environmental, hydrological, and mining exploration studies. Usually, data interpretation is accomplished by individual 1D models resulting often in ambiguous models. This fact can be explained by the way as the two different methodologies sample the medium beneath surface. Vertical Electrical Sounding (VES) is good in marking resistive structures, while Transient Electromagnetic sounding (TEM) is very sensitive to conductive structures. Another difference is VES is better to detect shallow structures, while TEM soundings can reach deeper layers. A Matlab program for 1D joint inversion of VES and TEM soundings was developed aiming at exploring the best of both methods. The program uses CRS - Controlled Random Search - algorithm for both single and 1D joint inversions. Usually inversion programs use Marquadt type algorithms but for electrical and electromagnetic methods, these algorithms may find a local minimum or not converge. Initially, the algorithm was tested with synthetic data, and then it was used to invert experimental data from two places in Paraná sedimentary basin (Bebedouro and Pirassununga cities), both located in São Paulo State, Brazil. Geoelectric model obtained from VES and TEM data 1D joint inversion is similar to the real geological condition, and ambiguities were minimized. Results with synthetic and real data show that 1D VES/TEM joint inversion better recovers simulated models and shows a great potential in geological studies, especially in hydrogeological studies.

  18. Challenges in quantitative crystallographic characterization of 3D thin films by ACOM-TEM

    Energy Technology Data Exchange (ETDEWEB)

    Kobler, A. [Institute of Nanotechnology (INT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen (Germany); Karlsruhe Nano Micro Facility (KNMF), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen (Germany); Kübel, C., E-mail: christian.kuebel@kit.edu [Institute of Nanotechnology (INT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen (Germany); Karlsruhe Nano Micro Facility (KNMF), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen (Germany)

    2017-02-15

    Automated crystal orientation mapping for transmission electron microscopy (ACOM-TEM) has become an easy to use method for the investigation of crystalline materials and complements other TEM methods by adding local crystallographic information over large areas. It fills the gap between high resolution electron microscopy and electron back scatter diffraction in terms of spatial resolution. Recent investigations showed that spot diffraction ACOM-TEM is a quantitative method with respect to sample parameters like grain size, twin density, orientation density and others. It can even be used in combination with in-situ tensile or thermal testing. However, there are limitations of the current method. In this paper we discuss some of the challenges and discuss solutions, e.g. we present an ambiguity filter that reduces the number of pixels with a ‘180° ambiguity problem’. For that an ACOM-TEM tilt series of nanocrystalline Pd thin films with overlapping crystallites was acquired and analyzed. - Highlights: • Tilt series of nanocrystalline Pd thin films. • Quantitative ACOM-TEM data processing, including a rotation map of crystallites. • Noise filter for orientation data: Ambiguity Filter and min. distance filter.

  19. A comparison of EDS microanalysis in FIB-prepared and electropolished TEM thin foils

    International Nuclear Information System (INIS)

    Hutchinson, C.R.; Hackenberg, R.E.; Shiflet, G.J.

    2003-01-01

    This paper reports the results of a fine-probe EDS microanalytical study of cellular precipitation in a Cu-Ti binary alloy. Compositional profiles across the solute depleted Cu-rich FCC lamellae and the Cu 4 Ti lamellae within isothermally formed cellular colonies were measured in a FEG-TEM from thin-foil specimens prepared by conventional electropolishing and by a technique using a Ga + focused ion-beam (FIB). The Cliff-Lorimer ratio method, with an absorption correction, was employed to quantify the compositions. Two FIB samples were prepared with different orientations of the lamellae with respect to the ion-milling direction. The compositional profiles across the Cu-rich FCC lamellae and the Cu 4 Ti compound lamellae in both the FIB-prepared samples and the electropolished sample were, within experimental error, numerically equivalent. The composition of the Cu 4 Ti compound phase lamellae was very close to the ideal stoichiometric composition of 20 at% Ti. It is concluded that for this system, and for the specimen preparation procedures used in this study, the Ga + ion-milling process has had no detectable effect on the chemistry changes across the interlamellar interface at the scale studied. These results indicate that the possible sources of chemical artifacts which include redeposition, preferential sputtering and ion-induced atomic migration can be minimized if several precautions are taken during milling in the FIB. Consistent with previous investigators, it was also found that the ion-milling process does introduce significant structural artifacts (e.g., dislocations) into the softer FCC Cu-rich phase compared with a specimen produced by conventional electropolishing

  20. A preliminary study of CdS for solar cells using combined TEM and cathodoluminescence

    International Nuclear Information System (INIS)

    Mam, K.; Durose, K.; Halliday, D.P.; Szczerbakow, A.

    2005-01-01

    A study of the suitability of a combined transmission electron microscope (TEM)/cathodoluminescence (CL) imaging and spectroscopy apparatus for investigations of CdS is presented. Photoluminescence (PL) was used to evaluate the effect of the Ar + and I + ion beam thinning used in TEM specimen preparation of CdS: a minor increase in yellow emission (594 nm) resulted. However, excitation of luminescence spectra in the TEM had a quenching effect on red luminescence (734 nm), this being considered due to the high excitation density compared to that in PL. Significant electron beam damage to the CdS could be avoided by using scanning transmission electron microscope (STEM) illumination in preference to the conventional TEM mode, which generally uses higher beam current density. Dislocation images were correlated with contrast in the STEM-CL imaging mode. The potential of the apparatus to make further direct correlations of CL images with diffraction contrast TEM imaging was assessed using the Rose visibility criterion

  1. Development of a versatile TEM specimen holder for the characterization of photocatalytic materials

    DEFF Research Database (Denmark)

    Cavalca, Filippo; Langhammer, C.; Hansen, Thomas Willum

    2011-01-01

    conventional TEM analysis on photocatalysts with several in situ TEM techniques including environmental TEM (ETEM), in situ photo activation and localized surface plasmon resonance (LSPR) spectroscopy [3-4]. These experiments are facilitated by the construction of a specimen holder capable of illuminating....../on nanomaterials and thin films. We present results from combined ETEM-LSPR studies of thermally-induced catalytic phenomena and on metal nanoparticle sintering, an important process in catalysis, which we study in situ in both real and model systems by means of indirect nanoplasmonic sensing and ETEM....

  2. A fast semi-analytical model for the slotted structure of induction motors

    NARCIS (Netherlands)

    Sprangers, R.L.J.; Paulides, J.J.H.; Gysen, B.L.J.; Lomonova, E.A.

    A fast, semi-analytical model for induction motors (IMs) is presented. In comparison to traditional analytical models for IMs, such as lumped parameter, magnetic equivalent circuit and anisotropic layer models, the presented model calculates a continuous distribution of the magnetic flux density in

  3. Quantitative analysis of TEM-8 and CEA tumor markers indicating free tumor cells in the peripheral blood of colorectal cancer patients.

    Science.gov (United States)

    Raeisossadati, Reza; Farshchian, Moein; Ganji, Azita; Tavassoli, Alieza; Velayati, Arash; Dadkhah, Ezzat; Chavoshi, Somaye; Mehrabi Bahar, Mostafa; Memar, Bahram; Rajabi Mashhadi, Mohammad Taghi; Naseh, Hossein; Forghanifard, Mohammad Mahdi; Moghbeli, Meysam; Moaven, Omeed; Abbaszadegan, Mohammad Reza

    2011-10-01

    Colorectal cancer (CRC) remains the third most common cancer in the world. Approximately in 50 percent of patients, metastatic disease is a major cause of death. Therefore, early diagnosis of CRC is crucial for a successful outcome. For the detection of circulating cancer cells, this study applied a sensitive method that employed specific tumor markers for early detection. A total of 80 blood samples from 40 CRC patients and 40 age-matched healthy controls were collected for the study. The circulating mRNA levels of two CRC tumor markers, tumor endothelial marker 8 (TEM-8) and carcinoembryogenic antigen (CEA) were evaluated using an absolute quantitative real-time PCR assay in a Stratagene Mx-3000P real-time PCR system. GAPDH was used as the endogenous control. TEM-8 and CEA were primarily detected more in the CRC patients rather than in the controls: 22/40 vs 9/40, p=0.009 and 30/40 vs 11/40, p=0.00054, respectively. In the CRC patients, the mRNA level of these markers was significantly higher in comparison to the normal controls (p=0.018 and 0.01). The overall sensitivity of this panel was 65% with a specificity of 75%. Statistical analysis for demographic variants did not reach significant values. TEM-8 and CEA markers were detected more frequently and in significantly higher levels in the blood samples of patients compared with samples from age-matched healthy controls. The copy number of CEA and TEM-8 mRNA, as detected by a real-time quantitative PCR, appears to be a promising marker for evaluating the risk of tumor spread.

  4. cisTEM, user-friendly software for single-particle image processing

    Science.gov (United States)

    2018-01-01

    We have developed new open-source software called cisTEM (computational imaging system for transmission electron microscopy) for the processing of data for high-resolution electron cryo-microscopy and single-particle averaging. cisTEM features a graphical user interface that is used to submit jobs, monitor their progress, and display results. It implements a full processing pipeline including movie processing, image defocus determination, automatic particle picking, 2D classification, ab-initio 3D map generation from random parameters, 3D classification, and high-resolution refinement and reconstruction. Some of these steps implement newly-developed algorithms; others were adapted from previously published algorithms. The software is optimized to enable processing of typical datasets (2000 micrographs, 200 k – 300 k particles) on a high-end, CPU-based workstation in half a day or less, comparable to GPU-accelerated processing. Jobs can also be scheduled on large computer clusters using flexible run profiles that can be adapted for most computing environments. cisTEM is available for download from cistem.org. PMID:29513216

  5. cisTEM, user-friendly software for single-particle image processing.

    Science.gov (United States)

    Grant, Timothy; Rohou, Alexis; Grigorieff, Nikolaus

    2018-03-07

    We have developed new open-source software called cis TEM (computational imaging system for transmission electron microscopy) for the processing of data for high-resolution electron cryo-microscopy and single-particle averaging. cis TEM features a graphical user interface that is used to submit jobs, monitor their progress, and display results. It implements a full processing pipeline including movie processing, image defocus determination, automatic particle picking, 2D classification, ab-initio 3D map generation from random parameters, 3D classification, and high-resolution refinement and reconstruction. Some of these steps implement newly-developed algorithms; others were adapted from previously published algorithms. The software is optimized to enable processing of typical datasets (2000 micrographs, 200 k - 300 k particles) on a high-end, CPU-based workstation in half a day or less, comparable to GPU-accelerated processing. Jobs can also be scheduled on large computer clusters using flexible run profiles that can be adapted for most computing environments. cis TEM is available for download from cistem.org. © 2018, Grant et al.

  6. In situ TEM experiments of electrochemical lithiation and delithiation of individual nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiao Hua; Liu, Yang; Huang, Jian Yu [Center for Integrated Nanotechnologies (CINT), Sandia National Laboratories, Albuquerque, New Mexico (United States); Kushima, Akihiro; Li, Ju [Department of Nuclear Science and Engineering and Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Zhang, Sulin [Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, Pennsylvania (United States); Zhu, Ting [Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia (United States)

    2012-07-15

    Understanding the microscopic mechanisms of electrochemical reaction and material degradation is crucial for the rational design of high-performance lithium ion batteries (LIBs). A novel nanobattery assembly and testing platform inside a transmission electron microscope (TEM) has been designed, which allows a direct study of the structural evolution of individual nanowire or nanoparticle electrodes with near-atomic resolution in real time. In this review, recent progresses in the study of several important anode materials are summarized. The consistency between in situ and ex situ results is shown, thereby validating the new in situ testing paradigm. Comparisons between a variety of nanostructures lead to the conclusion that electrochemical reaction and mechanical degradation are material specific, size dependent, and geometrically and compositionally sensitive. For example, a highly anisotropic lithiation in Si is observed, in contrast to the nearly isotropic response in Ge. The Ge nanowires can develop a spongy network, a unique mechanism for mitigating the large volume changes during cycling. The Si nanoparticles show a critical size of {proportional_to}150 nm below which fracture is averted during lithiation, and above which surface cracking, rather than central cracking, is observed. In carbonaceous nanomaterials, the lithiated multi-walled carbon nanotubes (MWCNTs) are drastically embrittled, while few-layer graphene nanoribbons remain mechanically robust after lithiation. This distinct contrast manifests a strong 'geometrical embrittlement' effect as compared to a relatively weak 'chemical embrittlement' effect. In oxide nanowires, discrete cracks in ZnO nanowires are generated near the lithiation reaction front, leading to leapfrog cracking, while a mobile dislocation cloud at the reaction front is observed in SnO{sub 2} nanowires. This contrast is corroborated by ab initio calculations that indicate a strong chemical embrittlement of Zn

  7. XRD and TEM analysis of microstructure in the welding zone of 9Cr ...

    Indian Academy of Sciences (India)

    Unknown

    XRD and TEM analysis of microstructure in the welding zone of. 9Cr–1Mo–V–Nb ... steel, which has highest Cr content in the heat-resisting. Cr–Mo ... This research provides essential ... film samples were observed under TEM and select elec-.

  8. Comparison between numerical and analytical results on the required rf current for stabilizing neoclassical tearing modes

    Science.gov (United States)

    Wang, Xiaojing; Yu, Qingquan; Zhang, Xiaodong; Zhang, Yang; Zhu, Sizheng; Wang, Xiaoguang; Wu, Bin

    2018-04-01

    Numerical studies on the stabilization of neoclassical tearing modes (NTMs) by electron cyclotron current drive (ECCD) have been carried out based on reduced MHD equations, focusing on the amount of the required driven current for mode stabilization and the comparison with analytical results. The dependence of the minimum driven current required for NTM stabilization on some parameters, including the bootstrap current density, radial width of the driven current, radial deviation of the driven current from the resonant surface, and the island width when applying ECCD, are studied. By fitting the numerical results, simple expressions for these dependences are obtained. Analysis based on the modified Rutherford equation (MRE) has also been carried out, and the corresponding results have the same trend as numerical ones, while a quantitative difference between them exists. This difference becomes smaller when the applied radio frequency (rf) current is smaller.

  9. Comparison of Analytical and Numerical Model of Adsorber/desorber of Silica Gel-Water Adsorption Heat Pump

    Directory of Open Access Journals (Sweden)

    Katarzyna Zwarycz-Makles

    2017-03-01

    Full Text Available In the paper comparison of an analytical and a numerical model of silica gel/water adsorber/desorber was presented. Adsorber/desorber as a part of the two–bed single–stage adsorption heat pump was discussed. The adsorption heat pump under consideration consists of an evaporator, two adsorber/desorber columns and a condenser. During operation of assumed adsorption heat pump only heat and mass transfer was taken into account. The both presented mathematical models were created to describe the temperature, heat and concentration changes in the adsorber/desorber and consequently to describe the performance of the adsorption heat pump. Adsorption equilibrium was described by the Dubinin-Astachov model. Adsorption and desorption process dynamics was described by application of the linear driving force model (LDF. In the analysis temperatures of evaporation and condensation were constant.

  10. Big Data Analytics with Datalog Queries on Spark.

    Science.gov (United States)

    Shkapsky, Alexander; Yang, Mohan; Interlandi, Matteo; Chiu, Hsuan; Condie, Tyson; Zaniolo, Carlo

    2016-01-01

    There is great interest in exploiting the opportunity provided by cloud computing platforms for large-scale analytics. Among these platforms, Apache Spark is growing in popularity for machine learning and graph analytics. Developing efficient complex analytics in Spark requires deep understanding of both the algorithm at hand and the Spark API or subsystem APIs (e.g., Spark SQL, GraphX). Our BigDatalog system addresses the problem by providing concise declarative specification of complex queries amenable to efficient evaluation. Towards this goal, we propose compilation and optimization techniques that tackle the important problem of efficiently supporting recursion in Spark. We perform an experimental comparison with other state-of-the-art large-scale Datalog systems and verify the efficacy of our techniques and effectiveness of Spark in supporting Datalog-based analytics.

  11. Combined interpretation of SkyTEM and high-resolution seismic data

    DEFF Research Database (Denmark)

    Høyer, Anne-Sophie; Lykke-Andersen, Holger; Jørgensen, Flemming Voldum

    2011-01-01

    made based on AEM (SkyTEM) and high-resolution seismic data from an area covering 10 km2 in the western part of Denmark. As support for the interpretations, an exploration well was drilled to provide lithological and logging information in the form of resistivity and vertical seismic profiling. Based...... on the resistivity log, synthetic SkyTEM responses were calculated with a varying number of gate-times in order to illustrate the effect of the noise-level. At the exploration well geophysical data were compared to the lithological log; in general there is good agreement. The same tendency was recognised when Sky...

  12. Analytic of elements for the determination of soil->plant transfer factors

    International Nuclear Information System (INIS)

    Liese, T.

    1985-02-01

    This article describes a part of the conventional analytical work, which was done to determine soil to plant transfer factors. The analytical methods, the experiments to find out the best way of sample digestion and the resulting analytical procedures are described. Analytical methods are graphite furnace atomic absorption spectrometry (GFAAS) and inductively coupled plasma atomic emission spectrometry (ICP-AES). In case of ICP-AES the necessity of right background correction and correction of the spectral interferences is shown. The reliability of the analytical procedure is demonstrated by measuring different kinds of standard reference materials and by comparison of AAS and AES. (orig./HP) [de

  13. TEM investigation of the microstructural evolution in nickel during MeV helium implantation

    International Nuclear Information System (INIS)

    Gadalla, A.A.; Jaeger, W.; Ehrhart, P.

    1986-01-01

    In a recent TEM investigation of high energy He-implanted copper the low average helium density could be understood by the observation of the coexistence of two types of vacancy agglomerates i.e. relaxed vacancy agglomerates in the form of stacking fault tetrahedra (SFT) and small bubbles. In order to arrive at a more systematic understanding of the evolution of the microstructure during high energy helium implantation we extended these TEM investigations to nickel. Of particular interest was also the minimum implantation dose necessary to precipitate bubbles that are large enough to be visible in the TEM. (orig./RK)

  14. A simple algorithm for measuring particle size distributions on an uneven background from TEM images

    DEFF Research Database (Denmark)

    Gontard, Lionel Cervera; Ozkaya, Dogan; Dunin-Borkowski, Rafal E.

    2011-01-01

    Nanoparticles have a wide range of applications in science and technology. Their sizes are often measured using transmission electron microscopy (TEM) or X-ray diffraction. Here, we describe a simple computer algorithm for measuring particle size distributions from TEM images in the presence of a...... application to images of heterogeneous catalysts is presented.......Nanoparticles have a wide range of applications in science and technology. Their sizes are often measured using transmission electron microscopy (TEM) or X-ray diffraction. Here, we describe a simple computer algorithm for measuring particle size distributions from TEM images in the presence...

  15. MORPHOLOGICAL ASPECTS OF HUMAN LENS CAPSULES - A COMPARATIVE LM, SEM AND TEM EXAMINATION

    NARCIS (Netherlands)

    JONGEBLOED, WL; KALICHARAN, D; LOS, LI; VANDERVEEN, G; WORST, JGF

    1991-01-01

    Lens capsules of patients of advanced age, obtained after extracapsular cataract surgery, were carefully prepared for a combined LM, TEM and SEM investigation, after preliminary washing and mounting onto a holder in a buffer solution. After pre-fixation with GA, samples were postfixed for LM/TEM and

  16. Challenges in quantitative crystallographic characterization of 3D thin films by ACOM-TEM.

    Science.gov (United States)

    Kobler, A; Kübel, C

    2017-02-01

    Automated crystal orientation mapping for transmission electron microscopy (ACOM-TEM) has become an easy to use method for the investigation of crystalline materials and complements other TEM methods by adding local crystallographic information over large areas. It fills the gap between high resolution electron microscopy and electron back scatter diffraction in terms of spatial resolution. Recent investigations showed that spot diffraction ACOM-TEM is a quantitative method with respect to sample parameters like grain size, twin density, orientation density and others. It can even be used in combination with in-situ tensile or thermal testing. However, there are limitations of the current method. In this paper we discuss some of the challenges and discuss solutions, e.g. we present an ambiguity filter that reduces the number of pixels with a '180° ambiguity problem'. For that an ACOM-TEM tilt series of nanocrystalline Pd thin films with overlapping crystallites was acquired and analyzed. Copyright © 2017. Published by Elsevier B.V.

  17. Integrated model for providing tactical emergency medicine support (TEMS): analysis of 120 tactical situations.

    Science.gov (United States)

    Vainionpää, T; Peräjoki, K; Hiltunen, T; Porthan, K; Taskinen, A; Boyd, J; Kuisma, M

    2012-02-01

    Various models for organising tactical emergency medicine support (TEMS) in law enforcement operations exist. In Helsinki, TEMS is organised as an integral part of emergency medical service (EMS) and applied in hostage, siege, bomb threat and crowd control situations and in other tactical situations after police request. Our aim was to analyse TEMS operations, patient profile, and the level of on-site care provided. We conducted a retrospective cohort study of TEMS operations in Helsinki from 2004 to 2009. Data were retrieved from EMS, hospital and dispatching centre files and from TEMS reports. One hundred twenty TEMS operations were analysed. Median time from dispatching to arrival on scene was 10 min [Interquartile Range (IQR) 7-14]. Median duration of operations was 41 min (IQR 19-63). Standby was the only activity in 72 operations, four patients were dead on arrival, 16 requests were called off en route and patient examination or care was needed in 28 operations. Twenty-eight patients (records retrieved) were alive on arrival and were classified as trauma (n = 12) or medical (n = 16). Of traumas, two sustained a gunshot wound, one sustained a penetrating abdominal wound, three sustained medium severity injuries and nine sustained minor injuries. There was neither on-scene nor in-hospital mortality among patients who were alive on arrival. The level of on-site care performed was basic life support in all cases. The results showed that TEMS integrated to daily EMS services including safe zone working only was a feasible, rapid and efficient way to provide medical support to law enforcement operations. © 2011 The Authors Acta Anaesthesiologica Scandinavica © 2011 The Acta Anaesthesiologica Scandinavica Foundation.

  18. SIZE OF BOEHMITE NANOPARTICLES BY TEM IMAGES ANALYSIS

    Directory of Open Access Journals (Sweden)

    Maxime Moreaud

    2011-05-01

    Full Text Available Transition aluminas, and especially the gamma type, are largely used as catalyst supports in refining and petrochemicals. Most studies focus on properties resulting from material texture and casting (specific surface, porous volume, pore shape and diameter. However, surface properties of alumina should be considered as well, as the catalytic activity is tightly related to the structure of exposed crystalline faces. As γ alumina results from controlled thermal treatment of boehmite γ-AlOOH by a topotactic transformation, the nature of exposed crystalline planes is related to the starting material. Therefore, the synthesis of the oxihydroxide γ-AlOOH, and especially size and shape of these particles, is critical in determining the relevant surface properties. Unlike often aggregated alumina, boehmite nanoparticles can be observed by TEM. Analysis of these TEM images can be performed to estimate the size of the boehmite nanoparticles. Information about morphology of the nanoparticles is obtained by the analysis of the covariance, modeling micrographs by a dilution model.

  19. Determining passive cooling limits in CPV using an analytical thermal model

    Science.gov (United States)

    Gualdi, Federico; Arenas, Osvaldo; Vossier, Alexis; Dollet, Alain; Aimez, Vincent; Arès, Richard

    2013-09-01

    We propose an original thermal analytical model aiming to predict the practical limits of passive cooling systems for high concentration photovoltaic modules. The analytical model is described and validated by comparison with a commercial 3D finite element model. The limiting performances of flat plate cooling systems in natural convection are then derived and discussed.

  20. Using Analytic Hierarchy Process in Textbook Evaluation

    Science.gov (United States)

    Kato, Shigeo

    2014-01-01

    This study demonstrates the application of the analytic hierarchy process (AHP) in English language teaching materials evaluation, focusing in particular on its potential for systematically integrating different components of evaluation criteria in a variety of teaching contexts. AHP is a measurement procedure wherein pairwise comparisons are made…

  1. On the way to high resolution TEM characterization of dual ion beam irradiated ODS steels

    International Nuclear Information System (INIS)

    Hsiung, L.; Tumey, S.; Fluss, M. J.; King, W.; Marian, J.; Kuntz, J.; Dasher, B. El; Serruys, Y.; Willaime, F.; Kimura, A.

    2009-01-01

    Fission and fusion energy application of ODS steels while appearing promising requires that many key science issues be resolved. Among these issues are our incomplete understanding of the effect of irradiation on low-temperature fracture properties, the role of fusion relevant helium and hydrogen transmutation gases on the deformation and fracture of irradiated material at low and high temperatures, radiation-induced solute segregation and phase stability, mechanisms of swelling suppression in ODS steels, and the effects of radiation damage on localized deformation. While planning to focus on all these issues we are particularly interested in the atomic scale mechanism by which helium is mitigated by the nano scale particles. In order to obtain insight we are performing analytical transmission electron microscopy (AEM), high resolution electron microscopy (HRTEM) to investigate micro-structural and micro-compositional changes and property alterations of Fe-Cr ferritic/martensitic and ODS steels driven by temperature and ion-beam irradiation with Fe, H, and He. As a beginning to a collaboration between LLNL and CEA-Saclay, we have carried out an irradiation of four specimens, Fe, Fe14%Cr, and two ODS steels (14% Cr and 16% Cr) using the dual beam facility at CEA-Saclay (JANNuS). An Fe 8+ beam was implanted at 24 MeV and helium was implanted through a degrader wheel with energies between 1.7 MeV and 1.3 MeV. The nominal radiation parameters were 40 to 25 DPA, 10 to 25 appm He/DPA ratio, and specimen temperatures of ∼425 deg. C. Our goal is to compare the evolved microstructure with respect to the accumulation of helium at or near the particle matrix interface. Preparatory to this first study we have made many hi-resolution analyses of the nano-particles in the two ODS steels which serve as a base line for comparison with the TEM post irradiation examination reported here. These base line studies are reported separately at this conference. (author)

  2. NPP Multi-Biome: TEM Calibration Data, 1992, R1

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: This data set contains one data file (.csv format) that is known as the Terrestrial Ecosystem Model (TEM) data set. The data provide pool sizes and fluxes...

  3. Location specific in situ TEM straining specimens made using FIB

    International Nuclear Information System (INIS)

    Field, R.D.; Papin, P.A.

    2004-01-01

    A method has been devised and demonstrated for producing in situ straining specimens for the transmission electron microscope (TEM) from specific locations in a sample using a dual-beam focused ion beam (FIB) instrument. The specimen is removed from a polished surface in the FIB using normal methods and then attached to a pre-fabricated substrate in the form of a modified TEM tensile specimen. In this manner, specific features of the microstructure of a polished optical mount can be selected for in situ tensile straining. With the use of electron backscattered diffraction (EBSD), this technique could be extended to select specific orientations of the specimen as well

  4. TEM1 expression in cancer-associated fibroblasts is correlated with a poor prognosis in patients with gastric cancer

    International Nuclear Information System (INIS)

    Fujii, Satoshi; Fujihara, Ayano; Natori, Kei; Abe, Anna; Kuboki, Yasutoshi; Higuchi, Youichi; Aizawa, Masaki; Kuwata, Takeshi; Kinoshita, Takahiro; Yasui, Wataru; Ochiai, Atsushi

    2015-01-01

    The cancer stroma, including cancer-associated fibroblasts (CAFs), is known to contribute to cancer cell progression and metastasis, suggesting that functional proteins expressed specifically in CAFs might be candidate molecular targets for cancer treatment. The purpose of the present study was to explore the possibility of using TEM1 (tumor endothelial marker 1), which is known to be expressed in several types of mesenchymal cells, as a molecular target by examining the impact of TEM1 expression on clinicopathological factors in gastric cancer patients. A total of 945 consecutive patients with gastric cancer who underwent surgery at the National Cancer Center Hospital East between January 2003 and July 2007 were examined using a tissue microarray approach. TEM1 expression in CAFs or vessel-associated cells was determined using immunohistochemical staining. Three items (CAF-TEM1-positivity, CAF-TEM1-intensity, and vessel-TEM1-intensity) were then examined to determine the correlations between the TEM1 expression status and the recurrence-free survival (RFS), overall survival (OS), cancer-related survival (COS), and other clinicopathological factors. Significant correlations between CAF-TEM1-positivity or CAF-TEM1-intensity and RFS, OS, or COS were observed (P < 0.001, Kaplan–Meier curves); however, no significant correlation between vessel-TEM1-intensity and RFS, OS, or COS was observed. A univariate analysis showed that CAF-TEM1-positivity and CAF-TEM1-intensity were each correlated with a scirrhous subtype, tumor depth, nodal status, distant metastasis, serosal invasion, lymphatic or venous vessel infiltrations, and pTMN stage. This study suggests that the inhibition of TEM1 expression specifically in the CAFs of gastric carcinoma might represent a new strategy for the treatment of gastric cancer

  5. NPP Multi-Biome: TEM Calibration Data, 1992, R1

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains one data file (.csv format) that is known as the Terrestrial Ecosystem Model (TEM) data set. The data provide pool sizes and fluxes of carbon...

  6. In situ TEM-tandem/implanter interface facility in Wuhan University for investigation of radiation effects

    International Nuclear Information System (INIS)

    Guo Liping; Li Ming; Liu Chuansheng; Song Bo; Ye Mingsheng; Fan Xiangjun; Fu Dejun

    2007-01-01

    Transmission electron microscope (TEM) interfaced to one or more ion implanters and/or accelerators, i.e. in situ TEM, provides effective tools to observe microstructural changes of studied samples during the ion irradiation. Evolution of both radiation damages and irradiation-induced nano-sized microstructures can be investigated with this technique, much more convenient than conventional ex situ techniques. In situ TEM technique has been widely applied in various fields, especially in the study of radiation damages of structural materials of fission and fusion nuclear reactors, and in evaluation and qualification of radioactive waste forms. Nowadays there are more than a dozen such facilities located in Japan, France, and the United States. Recently, we have constructed the first TEM-Tandem/Implanter interface facility of China in Wuhan University. A modified Hitachi H800 TEM was interfaced to a 200 kV ion implanter and a 2 x 1.7 MV tandem accelerator. Effective steps were taken to isolate the TEM from mechanical vibration from the ion beam line, and no obvious wobbling of the TEM image was observed during the ion implantation. The amorphization process of Si crystal irradiated by 115 keV N + ion beam was observed in the primary experiments, demonstrating that this interface facility is capable of in situ study of radiation effects. An online low energy gaseous ion source which may provide 1-20 keV H + and He + is under construction. (authors)

  7. Adlerian and Analytic Theory: A Case Presentation.

    Science.gov (United States)

    Myers, Kathleen M.; Croake, James W.

    1984-01-01

    Makes a theoretical comparison between Adlerian and analytic formulations of family assessment in a case study involving a recently divorced couple and a child with encopresis. Discussed the family relationship in terms of object relations theory emphasizing intrapsychic experience, and Adlerian theory emphasizing the purposes of behavior. (JAC)

  8. Agrupamentos epistemológicos de artigos publicados sobre big data analytics

    OpenAIRE

    FURLAN, Patricia Kuzmenko; LAURINDO, Fernando José Barbin

    2017-01-01

    Resumo A era do big data já é realidade para empresas e indivíduos, e a literatura acadêmica sobre o tema tem crescido rapidamente nos últimos anos. Neste artigo, pretendeu-se identificar quais são os principais nichos e vertentes de publicação sobre o big data analytics. A opção metodológica foi realizar pesquisa bibliométrica na base de dados ISI Web of Science, utilizando-se aquele termo para focar as práticas de gestão de big data. Foi possível identificar cinco grupos distintos dentre os...

  9. Analytical Propagation of Uncertainty in Life Cycle Assessment Using Matrix Formulation

    DEFF Research Database (Denmark)

    Imbeault-Tétreault, Hugues; Jolliet, Olivier; Deschênes, Louise

    2013-01-01

    with Monte Carlo results. The sensitivity and contribution of input parameters to output uncertainty were also analytically calculated. This article outlines an uncertainty analysis of the comparison between two case study scenarios. We conclude that the analytical method provides a good approximation...... on uncertainty calculation. This article shows the importance of the analytical method in uncertainty calculation, which could lead to a more complete uncertainty analysis in LCA practice....... uncertainty assessment is not a regular step in LCA. An analytical approach based on Taylor series expansion constitutes an effective means to overcome the drawbacks of the Monte Carlo method. This project aimed to test the approach on a real case study, and the resulting analytical uncertainty was compared...

  10. Detecting single-electron events in TEM using low-cost electronics and a silicon strip sensor.

    Science.gov (United States)

    Gontard, Lionel C; Moldovan, Grigore; Carmona-Galán, Ricardo; Lin, Chao; Kirkland, Angus I

    2014-04-01

    There is great interest in developing novel position-sensitive direct detectors for transmission electron microscopy (TEM) that do not rely in the conversion of electrons into photons. Direct imaging improves contrast and efficiency and allows the operation of the microscope at lower energies and at lower doses without loss in resolution, which is especially important for studying soft materials and biological samples. We investigate the feasibility of employing a silicon strip detector as an imaging detector for TEM. This device, routinely used in high-energy particle physics, can detect small variations in electric current associated with the impact of a single charged particle. The main advantages of using this type of sensor for direct imaging in TEM are its intrinsic radiation hardness and large detection area. Here, we detail design, simulation, fabrication and tests in a TEM of the front-end electronics developed using low-cost discrete components and discuss the limitations and applications of this technology for TEM.

  11. Structure and Output Characteristics of a TEM Array Fitted to a Fin Heat Exchanger

    Science.gov (United States)

    Zhang, Z.; Chen, L. N.; Chen, Z. J.; Xiao, G. Q.; Liu, Z. J.

    2015-06-01

    In the design of a thermoelectric generator, both the heat transfer area and the number of thermoelectric modules (TEMs) should be increased accordingly as the generator power increases; crucially, both aspects need to be coordinated. A kilowatt thermoelectric generator with a fin heat exchanger is proposed for use in a constant-speed diesel generator unit. Interior fins enhance convective heat transfer, whereas an exterior fin segment increases the heat transfer area. The heat transfer surface is double that of a plane heat exchanger, and the temperature field over the exterior fins is constrained to a one-dimensional distribution. Between adjoining exterior fins, there is a cooling water channel with trapezoid cross-section, enabling compact TEMs and cooling them. Hence, more TEMs are built as a series-parallel array of TEMs with lower resistance and more stable output current. Under nonuniform conditions, to prevent circulation and energy loss, bypass diodes and antidiodes are added. Experiments and numerical calculations show that, with matching and optimization of the heat exchanger and TEM array, a stable maximum output power is obtainable from the interior of the thermoelectric generator system, which can be connected to an external maximum power point tracking system.

  12. Analytical electron microscopy of neutron-irradiated reactor alloys

    International Nuclear Information System (INIS)

    Thomas, L.E.

    1982-01-01

    Exposure to the high neutron fluxes and temperatures from 400 to 650 0 C in the core region of a fast breeder reactor profoundly alters the microstructure and properties of structural steels and superalloys. The development of irradiation-induced voids, dislocations and precipitates, as well as segregation of alloying elements on a microscopic scale has been related to macroscopic swelling, creep, hardening and embrittlement which occur during prolonged exposures in reactor. Microanalytical studies using TEM/STEM methods, primarily energy dispersive x-ray (EDX) microanalysis, have greatly aided understanding of alloy behavior under irradiation. The main uses of analytical electron microscopy in studying irradiated alloys have been the identification of irradiation-induced precipitates and determination of the changes in local composition due to irradiation-induced solute segregation

  13. In situ TEM observations of unusual nanocrystallization in a Ti-based bulk metallic glass

    International Nuclear Information System (INIS)

    Yan, M.; Wang, D.J.; Shen, J.; Qian, M.

    2011-01-01

    In situ transmission electron microscopy (TEM) has been used to witness the nanocrystallization of amorphous Ti 42.5 Cu 40 Zr 10 Ni 5 Sn 2.5 . A crystallization front exists to separate the TEM sample into two parts with different thermal stabilities. The number density of the crystallization products varies significantly, with the precipitate sizes ranging from a few nanometres to ∼100 nm. Detailed TEM analysis suggests that oxygen is the most likely reason for realizing the unusual nanocrystallization. External thermal analysis also indicates that oxygen affects the crystallization.

  14. Analytical chemistry of nuclear materials

    International Nuclear Information System (INIS)

    1966-01-01

    The second panel on the Analytical Chemistry of Nuclear Materials was organized for two purposes: first, to advise the Seibersdorf Laboratory of the Agency on its future programme, and second, to review the results of the Second International Comparison of routine analysis of trace impurities in uranium and also the action taken as a result of the recommendations of the first panel in 1962. Refs, figs and tabs

  15. Determination of crystallographic and macroscopic orientation of planar structures in TEM

    DEFF Research Database (Denmark)

    Huang, X.; Liu, Q.

    1998-01-01

    With the aid of a double-tilt holder in a transmission electron microscope (TEM), simple methods are described for determination of the crystallographic orientation of a planar structure and for calculation of the macroscopic orientation of the planar structure. The correlation between a planar...... structure and a crystallographic plane can be found by comparing the differences in their trace directions on the projection plane and inclination angles with respect to that plane. The angles between the traces of planar structures and the sample axis measured from the TEM micrographs, which have been...

  16. Directrices para la construcción de un repositorio temático

    Directory of Open Access Journals (Sweden)

    Doria, María Vanesa

    2013-04-01

    Full Text Available La creación de repositorios de información institucionales y/o temáticos, en nuestros días es la clave para el acceso a producción científica de manera libre y abierta. Por lo tanto, el acceso a la información a través de repositorios de información se ve favorecido por las iniciativas que propone el Acceso Abierto (AA. Para la creación de un repositorio de información en el marco de la filosofía de AA es importante contar con directrices, éstas pretenden ser una guía general de aspectos básicos dónde se detallan los pasos necesarios para la creación de un repositorio. El presente trabajo recoge las directrices para la construcción de repositorios temáticos a partir de los siguientes puntos de referencia: finalidad, funciones, políticas y actividades. Aunque existe un consenso sobre que los repositorios temáticos fueron los primeros en aparecer, existe poca información sobre desarrollo y gestión de repositorios temáticos comparado con la amplitud de información alcanzada por repositorios institucionales

  17. ANALYTIC FITS FOR PARTIAL PHOTOIONIZATION CROSS-SECTIONS

    NARCIS (Netherlands)

    VERNER, DA; YAKOVLEV, DG

    We present a compact, uniform and complete set of analytic fits to the partial Hartree-Dirac-Slater photoionization cross sections for the ground state shells of all atoms and ions of elements from H to Zn (Z less-than-or-equal-to 30). Comparison with experiment and theory demonstrates generally

  18. Maredata: red temática sobre datos de investigación en abierto

    OpenAIRE

    Abadal Falgueras, Ernest; Aleixandre, Rafael; Canals, Agustí; Ferrer, Antonia; Garrigós, Irene; Hernández, Tony; López-Borrull, Alexandre; Mazón, José N.; Melero Melero, Remedios; Méndez Rodríguez, Eva María; Ollé, Eva; Peset Mancebo, María Fernanda

    2017-01-01

    [ES]El objetivo central de la red temática MAREDATA es aglutinar y consolidar la colaboración entre grupos de investigación españoles centrados en el estudio de los datos científicos y también establecer relación con aquellos sectores y disciplinas interesados en esta temática.

  19. Experimental and analytical evaluation of preheating temperature during multipass repair welding

    Directory of Open Access Journals (Sweden)

    Sedmak Aleksandar S.

    2017-01-01

    Full Text Available Experimental measurement and analytical calculation of preheating, i. e. interpass temperature during multi-pass repair welding has been presented. Analytical calculation is based on heat transfer analysis, whereas measurements have been performed by thermovision camera. Repair welding was performed on crane wheels in the Steelworks Smederevo. Comparison of results indicated that analytical calculation is good enough as the first approximation, but it needs further elaboration, e. g. taking into account the radiation component of heat dissipation and/or temperature dependence of material thermomechanical properties.

  20. Distortion of DNA Origami on Graphene Imaged with Advanced TEM Techniques.

    Science.gov (United States)

    Kabiri, Yoones; Ananth, Adithya N; van der Torre, Jaco; Katan, Allard; Hong, Jin-Yong; Malladi, Sairam; Kong, Jing; Zandbergen, Henny; Dekker, Cees

    2017-08-01

    While graphene may appear to be the ultimate support membrane for transmission electron microscopy (TEM) imaging of DNA nanostructures, very little is known if it poses an advantage over conventional carbon supports in terms of resolution and contrast. Microscopic investigations are carried out on DNA origami nanoplates that are supported onto freestanding graphene, using advanced TEM techniques, including a new dark-field technique that is recently developed in our lab. TEM images of stained and unstained DNA origami are presented with high contrast on both graphene and amorphous carbon membranes. On graphene, the images of the origami plates show severe unwanted distortions, where the rectangular shape of the nanoplates is significantly distorted. From a number of comparative control experiments, it is demonstrated that neither staining agents, nor screening ions, nor the level of electron-beam irradiation cause this distortion. Instead, it is suggested that origami nanoplates are distorted due to hydrophobic interaction of the DNA bases with graphene upon adsorption of the DNA origami nanoplates. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. The principle of electron microscopy; SEM and TEM

    International Nuclear Information System (INIS)

    Fauzi, S.H.

    1992-01-01

    The article reviews the principle of electron microscopy which is used in scanning electron microscope (SEM) and transmission electron microscope (TEM). These instruments are important for the examination and analysis of the microstructural properties of solid objects. Relevance physical concept lies behind the devices are given. The main components of each device are also discussed

  2. TEM characterization of UO2-Gd2O3 nuclear fuels synthesized by coprecipitation method

    International Nuclear Information System (INIS)

    Soldati, A.; Gana Watkins, I.; Menghini, J.; Prado, M.

    2013-01-01

    We present a micro and nano structural characterization of 4% weight doped Gd 2 O 3 -UO 2 pellet using Transmission Electron Microscopy (TEM). Agglomerate morphology and crystallite sizes were determined using light/dark field and high resolution (HR-TEM) images. Convergent beam Energy Dispersive Spectroscopy (EDS) and Electron Diffraction (ED) were used to evaluate sample composition and homogeneity, even at the nanometer scale. We obtained an average crystallite size of 90±20 nm. Moreover, from TEM-EDS analyses we determined the presence of Gadolinium in all the analyzed crystallites but with 25% variation among their concentrations. These results show the capability of TEM analysis to characterize a nuclear fuel pellet with burnable poisons nano structure and homogeneity.(author)

  3. Chemical and structural analysis of the bone-implant interface by TOF-SIMS, SEM, FIB and TEM: Experimental study in animal

    International Nuclear Information System (INIS)

    Palmquist, Anders; Emanuelsson, Lena; Sjövall, Peter

    2012-01-01

    Although bone-anchored implants are widely used in reconstructive medicine, the mechanism of osseointegration is still not fully understood. Novel analytical tools are needed to further understand this process, where both the chemical and structural aspects of the bone-implant interface are important. The aim of this study was to evaluate the advantages of combining time-of-flight secondary ion mass spectroscopy (TOF-SIMS) with optical (LM), scanning (SEM) and transmission electron microscopy (TEM) techniques for studying the bone-implant interface of bone-anchored implants. Laser-modified titanium implants with surrounded bone retrieved after 8 weeks healing in rabbit were dehydrated and resin embedded. Three types of sample preparation were studied to evaluate the information gained by combining TOF-SIMS, SEM, FIB and TEM. The results show that imaging TOF-SIMS can provide detailed chemical information, which in combination with structural information from microscopy methods provide a more complete characterization of anatomical structures at the bone-implant interface. By investigating various sample preparation techniques, it is shown that grinded cross section samples can be used for chemical imaging using TOF-SIMS, if careful consideration of potential preparation artifacts is taken into account. TOF-SIMS analysis of FIB-prepared bone/implant cross section samples show distinct areas corresponding to bone tissue and implant with a sharp interface, although without chemical information about the organic components.

  4. Quantitative evaluation of temporal partial coherence using 3D Fourier transforms of through-focus TEM images

    International Nuclear Information System (INIS)

    Kimoto, Koji; Sawada, Hidetaka; Sasaki, Takeo; Sato, Yuta; Nagai, Takuro; Ohwada, Megumi; Suenaga, Kazu; Ishizuka, Kazuo

    2013-01-01

    We evaluate the temporal partial coherence of transmission electron microscopy (TEM) using the three-dimensional (3D) Fourier transform (FT) of through-focus images. Young's fringe method often indicates the unexpected high-frequency information due to non-linear imaging terms. We have already used the 3D FT of axial (non-tilted) through-focus images to reduce the effect of non-linear terms on the linear imaging term, and demonstrated the improvement of monochromated lower-voltage TEM performance [Kimoto et al., Ultramicroscopy 121 (2012) 31–39]. Here we apply the 3D FT method with intentionally tilted incidence to normalize various factors associated with a TEM specimen and an imaging device. The temporal partial coherence of two microscopes operated at 30, 60 and 80 kV is evaluated. Our method is applicable to such cases where the non-linear terms become more significant in lower acceleration voltage or aberration-corrected high spatial resolution TEM. - Highlights: • We assess the temporal partial coherence of TEM using a 3-dimensional (3D) Fourier transform (FT) of through-focus images. • We apply the 3D FT method with intentionally tilted incidence to normalize various factors associated with a TEM specimen and an imaging device. • The spatial frequency at which information transfer decreases to 1/e 2 (13.5%) is determined for two lower-voltage TEM systems

  5. Nonlinear interplay of TEM and ITG turbulence and its effect on transport

    Science.gov (United States)

    Merz, F.; Jenko, F.

    2010-05-01

    The dominant source of anomalous transport in fusion plasmas on ion scales is turbulence driven by trapped electron modes (TEMs) and ion temperature gradient (ITG) modes. While the individual properties of each of these two instabilities and the corresponding microturbulence have been examined in detail in the past, the effects of a coexistence of the two modes and the phenomena of transitions between the TEM and ITG dominated regimes are not well studied. In many experimental situations, the temperature and density gradients support both microinstabilities simultaneously, so that transitional regimes are important for a detailed understanding of fusion plasmas. In this paper, this issue is addressed, using the gyrokinetic code GENE for a detailed investigation of the dominant and subdominant linear instabilities and the corresponding nonlinear system. A simple quasilinear model based on eigenvalue computations is presented which is shown to reproduce important features of the nonlinear TEM-ITG transition.

  6. An Analytic Hierarchy Process for School Quality and Inspection: Model Development and Application

    Science.gov (United States)

    Al Qubaisi, Amal; Badri, Masood; Mohaidat, Jihad; Al Dhaheri, Hamad; Yang, Guang; Al Rashedi, Asma; Greer, Kenneth

    2016-01-01

    Purpose: The purpose of this paper is to develop an analytic hierarchy planning-based framework to establish criteria weights and to develop a school performance system commonly called school inspections. Design/methodology/approach: The analytic hierarchy process (AHP) model uses pairwise comparisons and a measurement scale to generate the…

  7. Joint TEM and MT aquifer study in the Atacama Desert, North Chile

    Science.gov (United States)

    Ruthsatz, Alexander D.; Sarmiento Flores, Alvaro; Diaz, Daniel; Reinoso, Pablo Salazar; Herrera, Cristian; Brasse, Heinrich

    2018-06-01

    The Atacama Desert represents one of the driest regions on earth, and despite the absence of sustainable clean water reserves the demand has increased drastically since 1970 as a result of growing population and expanding mining activities. Magnetotelluric (MT) and Transient Electromagnetic (TEM) measurements were carried out for groundwater exploration in late 2015 in the area of the Profeta Basin at the western margin of the Chilean Precordillera. Both methods complement each other: While MT in general attains larger penetration depths, TEM allows better resolution of near surface layers; furthermore TEM is free from galvanic distortion. Data were collected along three profiles, enabling a continuous resistivity image from the surface to at least several hundred meters depth. TEM data were inverted in a 1-D manner, consistently yielding a poorly conductive near-surface layer with a thickness of approximately 30 m and below a well-conducting layer which we interpret as the aquifer with resistivities around 10 Ωm. At marginal sites of the main SW-NE-profile the resistive basement was found in 150 m. These depths are confirmed by interpretation of the MT soundings. Those were firstly inverted with a 2-D approach and then by 3-D inversion as clear indications of three-dimensionality exist. Several modeling runs were performed with different combinations of transfer functions and smoothing parameters. Generally, MT and TEM results agree reasonably well and an overall image of the resistivity structures in the Profeta Basin could be achieved. The aquifer reaches depths of more than 500 m in parts and, by applying Archie's law, resistivities of 1 Ωm can be assumed, indicating highly saline fluids from the source region of the surrounding high Andes under persisting arid conditions.

  8. Interface and thin film analysis: Comparison of methods, trends

    International Nuclear Information System (INIS)

    Werner, H.W.; Torrisi, A.

    1990-01-01

    Thin film properties are governed by a number of parameters such as: Surface and interface chemical composition, microstructure and the distribution of defects, dopants and impurities. For the determination of most of these aspects sophisticated analytical methods are needed. An overview of these analytical methods is given including: - Features and modes of analytical methods; - Main characteristics, advantages and disadvantages of the established methods [e.g. ESCA (Electron Spectroscopy for Chemical Analysis), AES (Auger Electron Spectroscopy), SIMS (Secondary Ion Mass Spectrometry), RBS (Rutherford Backscattering Spectrometry), SEM (Scanning Electron Microscopy), TEM (Transmission Electron Microscopy), illustrated with typical examples]; - Presentation of relatively new methods such as XRM (X-ray Microscopy) and SCAM (Scanning Acoustic Microscopy). Some features of ESCA (chemical information, insulator analysis, non-destructive depth profiling) have been selected for a more detailed presentation, viz. to illustrate the application of ESCA to practical problems. Trends in instrumental development and analytical applications of the techniques are discussed; the need for a multi-technique approach to solve complex analytical problems is emphasized. (orig.)

  9. Two-dimensional dopant profiling for shallow junctions by TEM and AFM

    International Nuclear Information System (INIS)

    Yoo, K.

    2000-01-01

    The present work concerns the development of the Etch/TEM and Etch/AFM methods to obtain quantitative 2-D dopant profiles for the ultra shallow p-n junctions of the next generation of metal-oxide-semiconductor field effect transistors (MOSFETs). For these methods, thin foil (TEM) or bulk (AFM) cross-sectional specimens were etched using a dopant selective chemical so that local areas of the dopant implanted source/drain (S/D) regions were etched to different depths. The surface topography of the S/D regions was determined from the thickness fringes for the TEM method and by the direct measurement for the AFM method. The local etched depths were converted to etch rates, and these were then converted to corresponding 1-D and 2-D dopant profiles by the experimentally independent etch rate calibration curves. Shallow junction MOSFET samples were designed and fabricated with junction depths 60nm (n + /p), 80nm (n + /p) and 120nm (p + /n) using 0.25μm process technology. A new method using SOG (Spin-on-Glass) contributed to the high quality XTEM thin foil specimens. Controlled stirring of the etchant increased the dopant concentration selectivity and etching consistency. Computer modelling simulated the isotropic etching behaviours, which can introduce the significant error in dopant profiling for shallow and abrupt junction samples. Comprehensive quantitative results enabled the optimum etching time to be determined for the first time. Etch/TEM method gave 1-D dopant profiles that showed good agreement with 1-D Spreading Resistance Probe (SRP) dopant profiles for determining junction depths. 2-D dopant profiles gave L eff , i.e. the shortest lateral distance between the S/D junctions, of major importance for MOSFET performance. Values for L eff of 161, 159 and 123nm were determined from 60, 80 and 120nm junction depth samples respectively, compared with the 215nm MOSFET gate length. The resolution and accuracy of the Etch/TEM method are estimated as 2 and 10nm

  10. Modeling of Coaxial Slot Waveguides Using Analytical and Numerical Approaches: Revisited

    Directory of Open Access Journals (Sweden)

    Kok Yeow You

    2012-01-01

    Full Text Available Our reviews of analytical methods and numerical methods for coaxial slot waveguides are presented. The theories, background, and physical principles related to frequency-domain electromagnetic equations for coaxial waveguides are reassessed. Comparisons of the accuracies of various types of admittance and impedance equations and numerical simulations are made, and the fringing field at the aperture sensor, which is represented by the lumped capacitance circuit, is evaluated. The accuracy and limitations of the analytical equations are explained in detail. The reasons for the replacement of analytical methods by numerical methods are outlined.

  11. Valid analytical performance specifications for combined analytical bias and imprecision for the use of common reference intervals.

    Science.gov (United States)

    Hyltoft Petersen, Per; Lund, Flemming; Fraser, Callum G; Sandberg, Sverre; Sölétormos, György

    2018-01-01

    Background Many clinical decisions are based on comparison of patient results with reference intervals. Therefore, an estimation of the analytical performance specifications for the quality that would be required to allow sharing common reference intervals is needed. The International Federation of Clinical Chemistry (IFCC) recommended a minimum of 120 reference individuals to establish reference intervals. This number implies a certain level of quality, which could then be used for defining analytical performance specifications as the maximum combination of analytical bias and imprecision required for sharing common reference intervals, the aim of this investigation. Methods Two methods were investigated for defining the maximum combination of analytical bias and imprecision that would give the same quality of common reference intervals as the IFCC recommendation. Method 1 is based on a formula for the combination of analytical bias and imprecision and Method 2 is based on the Microsoft Excel formula NORMINV including the fractional probability of reference individuals outside each limit and the Gaussian variables of mean and standard deviation. The combinations of normalized bias and imprecision are illustrated for both methods. The formulae are identical for Gaussian and log-Gaussian distributions. Results Method 2 gives the correct results with a constant percentage of 4.4% for all combinations of bias and imprecision. Conclusion The Microsoft Excel formula NORMINV is useful for the estimation of analytical performance specifications for both Gaussian and log-Gaussian distributions of reference intervals.

  12. TEM investigations of laser ablated particles

    International Nuclear Information System (INIS)

    Fliegel, D.; Dundas, S.; Kosler, J.; Klementova, M.

    2009-01-01

    Full text: Laser ablation inductively coupled plasma mass spectrometry suffers from fractionation effects hindering a non matrix matched calibration strategy. Different reasons for elemental fractionation that are related to the laser ablation, the transport and the vaporization in the plasma are discussed. One major question to be addressed linked to the vaporization yield in the ICP is in which of mineralogical phase the different ablated particle sizes enter the plasma. This contribution will investigate particles generated by a 213 nm laser from different samples such as minerals and alloys with respect to their chemical and phase compositions using high resolution TEM. (author)

  13. TEM and ellipsometry studies of nanolaminate oxide films prepared using atomic layer deposition

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, D.R.G. [Materials and Engineering Science, ANSTO, PMB 1, Menai, NSW 2234 (Australia)]. E-mail: drm@ansto.gov.au; Attard, D.J. [Materials and Engineering Science, ANSTO, PMB 1, Menai, NSW 2234 (Australia); Finnie, K.S. [Materials and Engineering Science, ANSTO, PMB 1, Menai, NSW 2234 (Australia); Triani, G. [Materials and Engineering Science, ANSTO, PMB 1, Menai, NSW 2234 (Australia); Barbe, C.J. [Materials and Engineering Science, ANSTO, PMB 1, Menai, NSW 2234 (Australia); Depagne, C. [Materials and Engineering Science, ANSTO, PMB 1, Menai, NSW 2234 (Australia); Bartlett, J.R. [Materials and Engineering Science, ANSTO, PMB 1, Menai, NSW 2234 (Australia)

    2005-04-30

    Nanolaminate oxide layers consisting of TiO{sub 2} and Al{sub 2}O{sub 3} have been deposited on silicon using atomic layer deposition (ALD). Characterisation of these films has been achieved by use of a range of modern transmission electron microscopy (TEM)-based techniques, including plasmon loss imaging, energy filtered imaging and scanning TEM (STEM) X-ray line profiling. These have shown that the target thickness of the individual layers in the nanolaminate structures (20 nm) has been met with a high degree of accuracy, that the layers are extremely flat and parallel and that the interfaces between the layers are compositionally abrupt. Localised crystallisation within the stacks, and responses to electron beam irradiation point to the presence of a stress gradient within the layers. The performance of ellipsometry in characterising multilayer stacks has been benchmarked against the TEM measurements. Errors in determination of individual layer thicknesses were found to increase with growing stack size, as expected given the increasing number of interfaces incorporated in each model. The most sophisticated model gave maximum deviations of {+-}4 nm from the TEM determined values for the 5- and 10-layer stacks.

  14. Characterization of some biological specimens using TEM and SEM

    Science.gov (United States)

    Ghosh, Nabarun; Smith, Don W.

    2009-05-01

    The advent of novel techniques using the Transmission and Scanning Electron Microscopes improved observation on various biological specimens to characterize them. We studied some biological specimens using Transmission and Scanning Electron Microscopes. We followed negative staining technique with Phosphotungstic acid using bacterial culture of Bacillus subtilis. Negative staining is very convenient technique to view the structural morphology of different samples including bacteria, phage viruses and filaments in a cell. We could observe the bacterial cell wall and flagellum very well when trapped the negative stained biofilm from bacterial culture on a TEM grid. We cut ultra thin sections from the fixed root tips of Pisum sativum (Garden pea). Root tips were pre fixed with osmium tetroxide and post fixed with uranium acetate and placed in the BEEM capsule for block making. The ultrathin sections on the grid under TEM showed the granular chromatin in the nucleus. The protein bodies and large vacuoles with the storage materials were conspicuous. We followed fixation, critical point drying and sputter coating with gold to view the tissues with SEM after placing on stubs. SEM view of the leaf surface of a dangerous weed Tragia hispida showed the surface trichomes. These trichomes when break on touching releases poisonous content causing skin irritation. The cultured tissue from in vitro culture of Albizia lebbeck, a tree revealed the regenerative structures including leaf buds and stomata on the tissue surface. SEM and TEM allow investigating the minute details characteristic morphological features that can be used for classroom teaching.

  15. Investigation of InN layers grown by MOCVD using analytical and high resolution TEM: The structure, band gap, role of the buffer layers

    International Nuclear Information System (INIS)

    Ruterana, P.; Abouzaid, M.; Gloux, F.; Maciej, W.; Doualan, J.L.; Drago, M.; Schmidtling, T.; Pohl, U.W.; Richter, W.

    2006-01-01

    In this work we investigate the microstructure of InN layers grown by MOCVD on different buffer layers using TEM (InN, GaN). The large mismatch between the various lattices (InN, sapphire or GaN) leads to particular interface structures. Our local analysis allows to show that at atomic scale, the material has the InN lattice parameters and that no metallic In precipitates are present, meaning that the PL emission below 0.8 eV is a genuine property of the InN semiconductor. It is also shown that the N polar layers, which exhibit a 2D growth, have poorer PL emission than In polar layers. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  16. Atom-counting in High Resolution Electron Microscopy:TEM or STEM - That's the question.

    Science.gov (United States)

    Gonnissen, J; De Backer, A; den Dekker, A J; Sijbers, J; Van Aert, S

    2017-03-01

    In this work, a recently developed quantitative approach based on the principles of detection theory is used in order to determine the possibilities and limitations of High Resolution Scanning Transmission Electron Microscopy (HR STEM) and HR TEM for atom-counting. So far, HR STEM has been shown to be an appropriate imaging mode to count the number of atoms in a projected atomic column. Recently, it has been demonstrated that HR TEM, when using negative spherical aberration imaging, is suitable for atom-counting as well. The capabilities of both imaging techniques are investigated and compared using the probability of error as a criterion. It is shown that for the same incoming electron dose, HR STEM outperforms HR TEM under common practice standards, i.e. when the decision is based on the probability function of the peak intensities in HR TEM and of the scattering cross-sections in HR STEM. If the atom-counting decision is based on the joint probability function of the image pixel values, the dependence of all image pixel intensities as a function of thickness should be known accurately. Under this assumption, the probability of error may decrease significantly for atom-counting in HR TEM and may, in theory, become lower as compared to HR STEM under the predicted optimal experimental settings. However, the commonly used standard for atom-counting in HR STEM leads to a high performance and has been shown to work in practice. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Long-Term Prediction of Satellite Orbit Using Analytical Method

    Directory of Open Access Journals (Sweden)

    Jae-Cheol Yoon

    1997-12-01

    Full Text Available A long-term prediction algorithm of geostationary orbit was developed using the analytical method. The perturbation force models include geopotential upto fifth order and degree and luni-solar gravitation, and solar radiation pressure. All of the perturbation effects were analyzed by secular variations, short-period variations, and long-period variations for equinoctial elements such as the semi-major axis, eccentricity vector, inclination vector, and mean longitude of the satellite. Result of the analytical orbit propagator was compared with that of the cowell orbit propagator for the KOREASAT. The comparison indicated that the analytical solution could predict the semi-major axis with an accuarcy of better than ~35meters over a period of 3 month.

  18. Characterization of crystallite morphology for doped strontium fluoride nanophosphors by TEM and XRD

    Energy Technology Data Exchange (ETDEWEB)

    O' Connell, J.H. [Centre for HRTEM, Nelson Mandela Metropolitan University, PO Box 77000, Port Elizabeth ZA6031 (South Africa); Lee, M.E., E-mail: Michael.lee@nmmu.ac.za [Centre for HRTEM, Nelson Mandela Metropolitan University, PO Box 77000, Port Elizabeth ZA6031 (South Africa); Yagoub, M.Y.A.; Swart, H.C.; Coetsee, E. [Department of Physics, University of the Free State, PO Box 339, Bloemfontein ZA9300 (South Africa)

    2016-01-01

    Crystallite morphology for Eu-doped and undoped SrF{sub 2} nanophosphors have been determined by X-ray diffraction (XRD) and transmission electron microscopy (TEM). The values for average crystallite size obtained by the application of the Scherrer equation and the full width at half maximum (FWHM) values for XRD peaks are compared to the results obtained using the hollow cone dark field (HCDF) TEM imaging technique. In the case of the TEM analysis, a bimodal crystallite size distribution was revealed with one of the distributions having a measured range of crystallite sizes which was in good agreement with the XRD data. HCDF in combination with FIB specimen preparation was found to be a promising technique for the determination of crystallite size distributions in nanophosphors which might facilitate a better understanding of their scintillation properties.

  19. Characterization of crystallite morphology for doped strontium fluoride nanophosphors by TEM and XRD

    International Nuclear Information System (INIS)

    O'Connell, J.H.; Lee, M.E.; Yagoub, M.Y.A.; Swart, H.C.; Coetsee, E.

    2016-01-01

    Crystallite morphology for Eu-doped and undoped SrF_2 nanophosphors have been determined by X-ray diffraction (XRD) and transmission electron microscopy (TEM). The values for average crystallite size obtained by the application of the Scherrer equation and the full width at half maximum (FWHM) values for XRD peaks are compared to the results obtained using the hollow cone dark field (HCDF) TEM imaging technique. In the case of the TEM analysis, a bimodal crystallite size distribution was revealed with one of the distributions having a measured range of crystallite sizes which was in good agreement with the XRD data. HCDF in combination with FIB specimen preparation was found to be a promising technique for the determination of crystallite size distributions in nanophosphors which might facilitate a better understanding of their scintillation properties.

  20. Quantitative TEM analysis of Al/Cu multilayer systems prepared by pulsed laser deposition

    DEFF Research Database (Denmark)

    Liu, Haihua; Pryds, Nini; Schou, Jørgen

    2010-01-01

    Thin films composed of alternating Al/Cu/Al layers were deposited on a (111) Si substrate using pulsed laser deposition (PLD). The thicknesses of the film and the individual layers, and the detailed internal structure within the layers were characterized by means of transmission electron microscopy...... for the formation of the first layer of nano-sized Al grains. The results demonstrate that the PLD technique is a powerful tool to produce nano-scale multilayered metal films with controllable thickness and grain sizes....... (TEM), high-resolution TEM (HRTEM), and energy-filtered TEM (EFTEM). Each Al or Cu layer consists of a single layer of nano-sized grains of different orientations. EFTEM results revealed a layer of oxide about 2 nm thick on the surface of the Si substrate, which is considered to be the reason...

  1. Present status and future prospects of spherical aberration corrected TEM/STEM for study of nanomaterials

    International Nuclear Information System (INIS)

    Tanaka, Nobuo

    2008-01-01

    The present status of Cs-corrected TEM/STEM is described from the viewpoint of the observation of nanomaterials. Characteristic features in TEM and STEM are explained using the experimental data obtained by our group and other research groups. Cs correction up to the 3rd-order aberration of an objective lens has already been established and research interest is focused on correcting the 5th-order spherical aberration and the chromatic aberration in combination with the development of a monochromator below an electron gun for smaller point-to-point resolution in optics. Another fundamental area of interest is the limitation of TEM and STEM resolution from the viewpoint of the scattering of electrons in crystals. The minimum size of the exit-wave function below samples undergoing TEM imaging is determined from the calculation of scattering around related atomic columns in the crystals. STEM does not have this limitation because the resolution is, in principle, determined by the probe size. One of the future prospects of Cs-corrected TEM/STEM is the possibility of extending the space around the sample holder by correcting the chromatic and spherical aberrations. This wider space will contribute to the ease of performing in situ experiments and various combinations of TEM and other analysis methods. High-resolution, in situ dynamic and 3D observations/analysis are the most important keywords in the next decade of high-resolution electron microscopy. (topical review)

  2. TEM and Moessbauer Study of Nano Sized Fe2MnAl Flakes

    International Nuclear Information System (INIS)

    Vinesh, A.; Sudheesh, V. D.; Lakshmi, N.; Venugopalan, K.

    2011-01-01

    Magnetic and structural properties of L21 ordered Fe 2 MnAl Heusler alloy have been studied by X-ray diffraction, Transmission electron microscopy (TEM), Moessbauer spectroscopy and DC magnetization. Structural texturing induced by ball milling is destroyed on heating while Moessbauer and DC magnetization studies show magnetic texturing persists after thermal treatment. TEM shows large distribution in particle size with an average size of 27 nm. Thermal annealing of ball milled sample results L2 1 ordering and the needle shaped particle contributes spin texturing.

  3. Three dimensional transient electromagnetic model study for fracture prediction from tunnel face; Sanjigen model keisan ni yoru TEM ho no tunnel zenpo tansa eno tekiyosei no kento

    Energy Technology Data Exchange (ETDEWEB)

    Wada, K; Tsutsui, T; Saito, A [Mitsui Mineral Development Engineering Co. Ltd., Tokyo (Japan); Hara, T [Toda Corp., Tokyo, (Japan); Zhdanov, M [University of Utah, UT (United States)

    1996-10-01

    In order to apply TEM model to fracture prediction at tunnel face, 3-D TEM model computation by FEM was conducted by installing a transmission loop on a tunnel face. MT field responses diffusing into the 3-D model were computed by time-domain difference calculus, and analytical precision was improved by introducing a staggered grid method. In the case where a low resistive zone exists before a tunnel face, time variance in diffused eddy current and induction current in the low resistive zone could be obtained. The difference in tunnel-axial transient curve (transient phenomenon curve in magnetic field) between uniform medium and low resistive zone models was based on the absorption process of diffused eddy current into the low resistive zone, and the expanding process of it toward the outside. Change in background condition could be predicted from the background and the ratio of transient curves every measurement. The detection limit of the low resistive zone was dependent on resistivity contrast, distance and geometry. Fluctuation in measurement due to noises and S/N ratio were also essential. 3 refs., 10 figs.

  4. Quantitative in situ TEM tensile testing of an individual nickel nanowire

    International Nuclear Information System (INIS)

    Lu Yang; Peng Cheng; Ganesan, Yogeeswaran; Lou Jun; Huang Jianyu

    2011-01-01

    In this paper, we have demonstrated the usage of a novel micro-mechanical device (MMD) to perform quantitative in situ tensile tests on individual metallic nanowires inside a transmission electron microscope (TEM). Our preliminary experiment on a 360 nm diameter nickel nanowire showed that the sample fractured at an engineering stress of ∼ 1.2 GPa and an engineering strain of ∼ 4%, which is consistent with earlier experiments performed inside a scanning electron microscope (SEM). With in situ high resolution TEM imaging and diffraction capabilities, this novel experimental set-up could provide unique opportunities to reveal the underlying deformation and damage mechanisms for metals at the nanoscale.

  5. Analytical solution for Van der Pol-Duffing oscillators

    International Nuclear Information System (INIS)

    Kimiaeifar, A.; Saidi, A.R.; Bagheri, G.H.; Rahimpour, M.; Domairry, D.G.

    2009-01-01

    In this paper, the problem of single-well, double-well and double-hump Van der Pol-Duffing oscillator is studied. Governing equation is solved analytically using a new kind of analytic technique for nonlinear problems namely the 'Homotopy Analysis Method' (HAM), for the first time. Present solution gives an expression which can be used in wide range of time for all domain of response. Comparisons of the obtained solutions with numerical results show that this method is effective and convenient for solving this problem. This method is a capable tool for solving this kind of nonlinear problems.

  6. TEM Characterization of High Burn-up Microstructure of U-7Mo Alloy

    Energy Technology Data Exchange (ETDEWEB)

    Jian Gan; Brandon Miller; Dennis Keiser; Adam Robinson; James Madden; Pavel Medvedev; Daniel Wachs

    2014-04-01

    As an essential part of global nuclear non-proliferation effort, the RERTR program is developing low enriched U-Mo fuels (< 20% U-235) for use in research and test reactors that currently employ highly enriched uranium fuels. One type of fuel being developed is a dispersion fuel plate comprised of U-7Mo particles dispersed in Al alloy matrix. Recent TEM characterizations of the ATR irradiated U-7Mo dispersion fuel plates include the samples with a local fission densities of 4.5, 5.2, 5.6 and 6.3 E+21 fissions/cm3 and irradiation temperatures of 101-136?C. The development of the irradiated microstructure of the U-7Mo fuel particles consists of fission gas bubble superlattice, large gas bubbles, solid fission product precipitates and their association to the large gas bubbles, grain subdivision to tens or hundreds of nanometer size, collapse of bubble superlattice, and amorphisation. This presentation will describe the observed microstructures specifically focusing on the U-7Mo fuel particles. The impact of the observed microstructure on the fuel performance and the comparison of the relevant features with that of the high burn-up UO2 fuels will be discussed.

  7. Continuous Analytical Performances Monitoring at the On-Site Laboratory through Proficiency, Inter-Laboratory Testing and Inter-Comparison Analytical Methods

    International Nuclear Information System (INIS)

    Duhamel, G.; Decaillon, J.-G.; Dashdondog, S.; Kim, C.-K.; Toervenyi, A.; Hara, S.; Kato, S.; Kawaguchi, T.; Matsuzawa, K.

    2015-01-01

    Since 2008, as one measure to strengthen its quality management system, the On-Site Laboratory for nuclear safeguards at the Rokkasho Reprocessing Plant, has increased its participation in domestic and international proficiency and inter-laboratory testing for the purpose of determining analytical method accuracy, precision and robustness but also to support method development and improvement. This paper provides a description of the testing and its scheduling. It presents the way the testing was optimized to cover most of the analytical methods at the OSL. The paper presents the methodology used for the evaluation of the obtained results based on Analysis of variance (ANOVA). Results are discussed with respect to random, systematic and long term systematic error. (author)

  8. Double aberration-corrected TEM/STEM of tungstated zirconia nanocatalysts for the synthesis of paracetamol

    International Nuclear Information System (INIS)

    Yoshida, K; Boyes, E D; Gai, P L; Shiju, N R; Brown, D R

    2010-01-01

    We report highly active tungstated zirconia nanocatalysts for the synthesis of paracetamol by Beckmann rearrangement of 4-hydroxyacetophenone oxime. Double aberration-corrected (2AC)-TEM/STEM studies were performed in a JEOL 2200FS FEG TEM/STEM at the 1 Angstrom (1 A = 0.1 nanometer) level. Observations at close to zero defocus were carried out using the AC-TEM as well as AC-STEM including high angle annular dark field (HAADF) imaging, from the same areas of the catalyst crystallites. The studies from the same areas have revealed the location and the nanostructure of the polytungstate species (clusters) and the nanograins of zirconia. The AC (S)TEM was crucial to observe the nanostructure and location of polytungstate clusters on the zirconia grains. Polytungstate clusters as small as 0.5 nm have been identified using the HAADF-STEM. The nanostructures of the catalyst and the W surface density have been correlated with paracetamol reaction studies. The results demonstrate the nature of active sites and high activity of the tungstated zirconia nanocatalyst, which is an environmentally clean alternative to the current homogeneous process.

  9. Double aberration-corrected TEM/STEM of tungstated zirconia nanocatalysts for the synthesis of paracetamol

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, K; Boyes, E D; Gai, P L [York JEOL Nanocentre (United Kingdom); Shiju, N R; Brown, D R, E-mail: pgb500@york.ac.u [Department of Chemical and Biological Sciences, University of Huddersfield, Huddersfield, HD1 3DH (United Kingdom)

    2010-07-01

    We report highly active tungstated zirconia nanocatalysts for the synthesis of paracetamol by Beckmann rearrangement of 4-hydroxyacetophenone oxime. Double aberration-corrected (2AC)-TEM/STEM studies were performed in a JEOL 2200FS FEG TEM/STEM at the 1 Angstrom (1 A = 0.1 nanometer) level. Observations at close to zero defocus were carried out using the AC-TEM as well as AC-STEM including high angle annular dark field (HAADF) imaging, from the same areas of the catalyst crystallites. The studies from the same areas have revealed the location and the nanostructure of the polytungstate species (clusters) and the nanograins of zirconia. The AC (S)TEM was crucial to observe the nanostructure and location of polytungstate clusters on the zirconia grains. Polytungstate clusters as small as 0.5 nm have been identified using the HAADF-STEM. The nanostructures of the catalyst and the W surface density have been correlated with paracetamol reaction studies. The results demonstrate the nature of active sites and high activity of the tungstated zirconia nanocatalyst, which is an environmentally clean alternative to the current homogeneous process.

  10. Comparison of maximum runup through analytical and numerical approaches for different fault parameters estimates

    Science.gov (United States)

    Kanoglu, U.; Wronna, M.; Baptista, M. A.; Miranda, J. M. A.

    2017-12-01

    The one-dimensional analytical runup theory in combination with near shore synthetic waveforms is a promising tool for tsunami rapid early warning systems. Its application in realistic cases with complex bathymetry and initial wave condition from inverse modelling have shown that maximum runup values can be estimated reasonably well. In this study we generate a simplistic bathymetry domains which resemble realistic near-shore features. We investigate the accuracy of the analytical runup formulae to the variation of fault source parameters and near-shore bathymetric features. To do this we systematically vary the fault plane parameters to compute the initial tsunami wave condition. Subsequently, we use the initial conditions to run the numerical tsunami model using coupled system of four nested grids and compare the results to the analytical estimates. Variation of the dip angle of the fault plane showed that analytical estimates have less than 10% difference for angles 5-45 degrees in a simple bathymetric domain. These results shows that the use of analytical formulae for fast run up estimates constitutes a very promising approach in a simple bathymetric domain and might be implemented in Hazard Mapping and Early Warning.

  11. Analysis and design of a coupled coaxial line TEM resonator for magnetic resonance imaging

    International Nuclear Information System (INIS)

    Benahmed, Nasreddine; Feham, Mohammed; Khelif, M'Hamed

    2006-01-01

    In this paper, we have successfully realized a numerical tool to analyse and to design an n-element unloaded coaxial line transverse electromagnetic (TEM) resonator. This numerical tool allows the determination of the primary parameters, matrices [L], [C] and [R], and simulates the frequency response of S 11 at the RF port of the designed TEM resonator. The frequency response permits evaluation of the unloaded quality factor Q 0 . As an application, we present the analysis and the design of an eight-element unloaded TEM resonator for animal studies at 4.7 T. The simulated performance has a -62.81 dB minimum reflection and a quality factor of 260 around 200 MHz

  12. An analytical solution for improved HIFU SAR estimation

    International Nuclear Information System (INIS)

    Dillon, C R; Vyas, U; Christensen, D A; Roemer, R B; Payne, A

    2012-01-01

    Accurate determination of the specific absorption rates (SARs) present during high intensity focused ultrasound (HIFU) experiments and treatments provides a solid physical basis for scientific comparison of results among HIFU studies and is necessary to validate and improve SAR predictive software, which will improve patient treatment planning, control and evaluation. This study develops and tests an analytical solution that significantly improves the accuracy of SAR values obtained from HIFU temperature data. SAR estimates are obtained by fitting the analytical temperature solution for a one-dimensional radial Gaussian heating pattern to the temperature versus time data following a step in applied power and evaluating the initial slope of the analytical solution. The analytical method is evaluated in multiple parametric simulations for which it consistently (except at high perfusions) yields maximum errors of less than 10% at the center of the focal zone compared with errors up to 90% and 55% for the commonly used linear method and an exponential method, respectively. For high perfusion, an extension of the analytical method estimates SAR with less than 10% error. The analytical method is validated experimentally by showing that the temperature elevations predicted using the analytical method's SAR values determined for the entire 3D focal region agree well with the experimental temperature elevations in a HIFU-heated tissue-mimicking phantom. (paper)

  13. Analytical and semi-analytical formalism for the voltage and the current sources of a superconducting cavity under dynamic detuning

    CERN Document Server

    Doleans, M

    2003-01-01

    Elliptical superconducting radio frequency (SRF) cavities are sensitive to frequency detuning because they have a high Q value in comparison with normal conducting cavities and weak mechanical properties. Radiation pressure on the cavity walls, microphonics, and tuning system are possible sources of dynamic detuning during SRF cavity-pulsed operation. A general analytic relation between the cavity voltage, the dynamic detuning function, and the RF control function is developed. This expression for the voltage envelope in a cavity under dynamic detuning and dynamic RF controls is analytically expressed through an integral formulation. A semi-analytical scheme is derived to calculate the voltage behavior in any practical case. Examples of voltage envelope behavior for different cases of dynamic detuning and RF control functions are shown. The RF control function for a cavity under dynamic detuning is also investigated and as an application various filling schemes are presented.

  14. A flexible multi-stimuli in situ (S)TEM: Concept, optical performance, and outlook

    International Nuclear Information System (INIS)

    Börrnert, Felix; Müller, Heiko; Riedel, Thomas; Linck, Martin; Kirkland, Angus I.; Haider, Max.; Büchner, Bernd; Lichte, Hannes

    2015-01-01

    The progress in (scanning) transmission electron microscopy development had led to an unprecedented knowledge of the microscopic structure of functional materials at the atomic level. Additionally, although not widely used yet, electron holography is capable to map the electric and magnetic potential distributions at the sub-nanometer scale. Nevertheless, in situ studies inside a (scanning) transmission electron microscope ((S)TEM) are extremely challenging because of the much restricted size and accessibility of the sample space. Here, we introduce a concept for a dedicated in situ (S)TEM with a large sample chamber for flexible multi-stimuli experimental setups and report about the electron optical performance of the instrument. We demonstrate a maximum resolving power of about 1 nm in conventional imaging mode and substantially better than 5 nm in scanning mode while providing an effectively usable “pole piece gap” of 70 mm. - Highlights: • A concept for a (S)TEM with a large sample chamber is outlined. • An actual microscope is modified and has now a 70 mm high sample space. • The resolving power is about 1 nm in TEM and better than 5 nm in STEM mode. • Possible dedicated in situ microscopes with present technology are discussed

  15. A flexible multi-stimuli in situ (S)TEM: Concept, optical performance, and outlook

    Energy Technology Data Exchange (ETDEWEB)

    Börrnert, Felix, E-mail: felix.boerrnert@triebenberg.de [Speziallabor Triebenberg, Technische Universität Dresden, 01062 Dresden (Germany); IFW Dresden, PF 27 01 16, 01171 Dresden (Germany); Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Müller, Heiko; Riedel, Thomas; Linck, Martin [CEOS GmbH, Englerstraße 28, 69126 Heidelberg (Germany); Kirkland, Angus I. [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Haider, Max. [CEOS GmbH, Englerstraße 28, 69126 Heidelberg (Germany); Büchner, Bernd [IFW Dresden, PF 27 01 16, 01171 Dresden (Germany); Lichte, Hannes [Speziallabor Triebenberg, Technische Universität Dresden, 01062 Dresden (Germany)

    2015-04-15

    The progress in (scanning) transmission electron microscopy development had led to an unprecedented knowledge of the microscopic structure of functional materials at the atomic level. Additionally, although not widely used yet, electron holography is capable to map the electric and magnetic potential distributions at the sub-nanometer scale. Nevertheless, in situ studies inside a (scanning) transmission electron microscope ((S)TEM) are extremely challenging because of the much restricted size and accessibility of the sample space. Here, we introduce a concept for a dedicated in situ (S)TEM with a large sample chamber for flexible multi-stimuli experimental setups and report about the electron optical performance of the instrument. We demonstrate a maximum resolving power of about 1 nm in conventional imaging mode and substantially better than 5 nm in scanning mode while providing an effectively usable “pole piece gap” of 70 mm. - Highlights: • A concept for a (S)TEM with a large sample chamber is outlined. • An actual microscope is modified and has now a 70 mm high sample space. • The resolving power is about 1 nm in TEM and better than 5 nm in STEM mode. • Possible dedicated in situ microscopes with present technology are discussed.

  16. Interpretation of interfacial structures in X-ray multilayers by TEM Fresnel fringe effects

    OpenAIRE

    Nguyen, Tai D.; O'Keefe, Michael A.; Kilaas, Roar; Gronsky, Ronald; Kortright, Jeffrey B.

    1991-01-01

    Assessment of interfacial structures from high-resolution TEM images of cross-sectional specimens is difficult due to Fresnel fringe effects producing different apparent structures in the images. The effects of these fringes have been commonly over-looked in efforts of making quantitative interpretation of interfacial profiles. In this report, we present the observations of the Fresnel fringes in nanometer period Mo/Si, W/C, and WC/C multilayers in through-focus-series TEM images. Calculation...

  17. Coordinated Isotopic and TEM Studies of Presolar Graphites from Murchison

    Science.gov (United States)

    Croat, T. K.; Stadermann, F. J.; Zinner, E.; Bernatowicz, T. J.

    2004-03-01

    TEM and NanoSIMS investigations of the same presolar Murchison KFC graphites revealed high Zr, Mo, and Ru content in refractory carbides within the graphites. Along with isotopically light carbon, these suggest a low-metallicity AGB source.

  18. The Influence of Judgment Calls on Meta-Analytic Findings.

    Science.gov (United States)

    Tarrahi, Farid; Eisend, Martin

    2016-01-01

    Previous research has suggested that judgment calls (i.e., methodological choices made in the process of conducting a meta-analysis) have a strong influence on meta-analytic findings and question their robustness. However, prior research applies case study comparison or reanalysis of a few meta-analyses with a focus on a few selected judgment calls. These studies neglect the fact that different judgment calls are related to each other and simultaneously influence the outcomes of a meta-analysis, and that meta-analytic findings can vary due to non-judgment call differences between meta-analyses (e.g., variations of effects over time). The current study analyzes the influence of 13 judgment calls in 176 meta-analyses in marketing research by applying a multivariate, multilevel meta-meta-analysis. The analysis considers simultaneous influences from different judgment calls on meta-analytic effect sizes and controls for alternative explanations based on non-judgment call differences between meta-analyses. The findings suggest that judgment calls have only a minor influence on meta-analytic findings, whereas non-judgment call differences between meta-analyses are more likely to explain differences in meta-analytic findings. The findings support the robustness of meta-analytic results and conclusions.

  19. A TEM method for analyzing local strain fields in irradiated materials

    International Nuclear Information System (INIS)

    Bennetch, J.I.; Jesser, W.A.

    1983-01-01

    Of great interest to the field of fracture mechanics is the strain field in front of a crack tip. In irradiated materials, cavities which naturally form as a result of radiation provide convenient internal markers. If a miniaturized irradiated tensile sample is pulled in situ in a transmission electron microscope (TEM), both the relative displacement of these cavities and their distortion in shape provide information on localized strain on a microscopic level. In addition, the TEM method allows direct correlation of active slip systems with crack propagation characteristics. To illustrate this method a strain field map was constructed about a crack propagating in a helium irradiated type 316 stainless steel sample containing large cavities. (orig.)

  20. Analytical evaluation of the novel Lumipulse G BRAHMS procalcitonin immunoassay

    OpenAIRE

    Ruzzenente, Orazio; Salvagno, Gian Luca; Gelati, Matteo; Lippi, Giuseppe

    2016-01-01

    Objectives: This study was designed to evaluate the analytical performance of the novel Lumipulse G1200 BRAHMS procalcitonin (PCT) immunoassay. Design and methods: This analytical evaluation encompassed the calculation of the limit of blank (LOB), limit of detection (LOD), functional sensitivity, intra- and inter-assay imprecision, confirmation of linearity and a comparison with the Vidas BRAHMS PCT assay. Results: The LOB, LOD and functional sensitivity were 0.0010 ng/mL, 0.0016 ng/mL and ...

  1. Application effect of TEM sounding survey on prospecting and target area selection of sandstone-type uranium deposits

    International Nuclear Information System (INIS)

    He Jianguo; Liang Shanming; Zhao Cuiping

    2006-01-01

    Based on the results of transient electromagnetic (TEM) sounding survey during recent years regional geological reconnaissance with drilling (1:250000), the application effect of TEM sounding survey during regional reconnaissance is summarized in this paper. It is suggested that the data of TEM sounding are useful in judging hydrodynamic conditions of groundwater and determining favorable areas for uranium ore-formation; TEM sounding in large areas may be proper for prospecting in gobi-desert areas and be beneficial for regional reconnaissance and target area selection, and may reduce the target area and provide basis for further drilling program. It is of popularized significance in the prospecting for sandstone-type uranium deposits. (authors)

  2. Four-parameter analytical local model potential for atoms

    International Nuclear Information System (INIS)

    Fei, Yu; Jiu-Xun, Sun; Rong-Gang, Tian; Wei, Yang

    2009-01-01

    Analytical local model potential for modeling the interaction in an atom reduces the computational effort in electronic structure calculations significantly. A new four-parameter analytical local model potential is proposed for atoms Li through Lr, and the values of four parameters are shell-independent and obtained by fitting the results of X a method. At the same time, the energy eigenvalues, the radial wave functions and the total energies of electrons are obtained by solving the radial Schrödinger equation with a new form of potential function by Numerov's numerical method. The results show that our new form of potential function is suitable for high, medium and low Z atoms. A comparison among the new potential function and other analytical potential functions shows the greater flexibility and greater accuracy of the present new potential function. (atomic and molecular physics)

  3. ANALISIS JARINGAN UMTS PADA MENARA ROOFTOP DENGAN MENGGUNAKAN SOFTWARE TEMS INVESTIGATION DAN G-NETTRACK PRO

    Directory of Open Access Journals (Sweden)

    Pande Putu Wahyu Pramanda

    2016-03-01

    Full Text Available Berkembangnya dunia teknologi telekomunikasi dan informasi sejalan dengan kebutuhan akan kecepatan dan kestabilan akses internet teknologi UMTS. Metode drive test adalah metode yang biasanya digunakan untuk pengukuran kualitas sebuah site. Pihak provider umumnya menggunakan software TEMS Investigation dalam melakukan drive test. Melakukan drive test dengan TEMS Investigation sangatlah tidak praktis dan memerlukan biaya yang besar. Berkembangnya teknologi smartphone membuat drive test dapat dilakukan dengan menggunakan handphone yaitu dengan G-NetTrack Pro. Namun G-NetTrack Pro tidak memiliki kemampuan yang sama dengan TEMS Investigation. Software G-NetTrack Pro dapat digunakan sebagai bahan pembelajaran yaitu untuk pengenalan drivetest namun belum cocok digunakan secara profesional. G-NetTrack Pro dapat menampilkan data yang dibutuhkan dalam drive test namun tidak sedetail TEMS Investigation, sehingga dalam proses pembelajaran dapat digunakan untuk pengenalan karena efisien dan dapat di install pada handphone mahasiswa namun tidak dapat digunakan melakukan drive test misalnya dalam dunia kerja atau secara professional.

  4. Helicopter TEM parameters analysis and system optimization based on time constant

    Science.gov (United States)

    Xiao, Pan; Wu, Xin; Shi, Zongyang; Li, Jutao; Liu, Lihua; Fang, Guangyou

    2018-03-01

    Helicopter transient electromagnetic (TEM) method is a kind of common geophysical prospecting method, widely used in mineral detection, underground water exploration and environment investigation. In order to develop an efficient helicopter TEM system, it is necessary to analyze and optimize the system parameters. In this paper, a simple and quantitative method is proposed to analyze the system parameters, such as waveform, power, base frequency, measured field and sampling time. A wire loop model is used to define a comprehensive 'time constant domain' that shows a range of time constant, analogous to a range of conductance, after which the characteristics of the system parameters in this domain is obtained. It is found that the distortion caused by the transmitting base frequency is less than 5% when the ratio of the transmitting period to the target time constant is greater than 6. When the sampling time window is less than the target time constant, the distortion caused by the sampling time window is less than 5%. According to this method, a helicopter TEM system, called CASHTEM, is designed, and flight test has been carried out in the known mining area. The test results show that the system has good detection performance, verifying the effectiveness of the method.

  5. 3D TEM reconstruction and segmentation process of laminar bio-nanocomposites

    International Nuclear Information System (INIS)

    Iturrondobeitia, M.; Okariz, A.; Fernandez-Martinez, R.; Jimbert, P.; Guraya, T.; Ibarretxe, J.

    2015-01-01

    The microstructure of laminar bio-nanocomposites (Poly (lactic acid)(PLA)/clay) depends on the amount of clay platelet opening after integration with the polymer matrix and determines the final properties of the material. Transmission electron microscopy (TEM) technique is the only one that can provide a direct observation of the layer dispersion and the degree of exfoliation. However, the orientation of the clay platelets, which affects the final properties, is practically immeasurable from a single 2D TEM image. This issue can be overcome using transmission electron tomography (ET), a technique that allows the complete 3D characterization of the structure, including the measurement of the orientation of clay platelets, their morphology and their 3D distribution. ET involves a 3D reconstruction of the study volume and a subsequent segmentation of the study object. Currently, accurate segmentation is performed manually, which is inefficient and tedious. The aim of this work is to propose an objective/automated segmentation methodology process of a 3D TEM tomography reconstruction. In this method the segmentation threshold is optimized by minimizing the variation of the dimensions of the segmented objects and matching the segmented V clay (%) and the actual one. The method is first validated using a fictitious set of objects, and then applied on a nanocomposite

  6. Analytical solutions for ozone generation by point to plane corona discharge

    International Nuclear Information System (INIS)

    Bestman, A.R.

    1990-12-01

    A recent mathematical model developed for ozone production is tackled analytically by asymptotic approximation. The results obtained are compared with existing numerical solutions. The comparison shows good agreement. (author). 3 refs, 1 fig

  7. Social comparison as a predictor of body dissatisfaction: A meta-analytic review.

    Science.gov (United States)

    Myers, Taryn A; Crowther, Janis H

    2009-11-01

    The relationship between social comparison and body dissatisfaction was examined using meta-analysis. Several demographic and methodological variables were examined as potential moderators. Data from 156 studies (189 effect sizes) showed that social comparison was related to higher levels of body dissatisfaction. The effect for social comparison and body dissatisfaction was stronger for women than men and inversely related to age. This effect was stronger when social comparison was directly measured rather than inferred. No differences emerged for the presence of eating psychopathology, study design, or object of comparison. Results confirm theory and research suggesting that comparing oneself unfavorably to another on the basis of appearance may lead to dissatisfaction with one's own appearance. Moderator variables refine our understanding of the social comparison-body dissatisfaction relationship. These constructs and their relationship should be explored further in future studies. PsycINFO Database Record 2009 APA, all rights reserved.

  8. Crystal growth of pure substances: Phase-field simulations in comparison with analytical and experimental results

    Science.gov (United States)

    Nestler, B.; Danilov, D.; Galenko, P.

    2005-07-01

    A phase-field model for non-isothermal solidification in multicomponent systems [SIAM J. Appl. Math. 64 (3) (2004) 775-799] consistent with the formalism of classic irreversible thermodynamics is used for numerical simulations of crystal growth in a pure material. The relation of this approach to the phase-field model by Bragard et al. [Interface Science 10 (2-3) (2002) 121-136] is discussed. 2D and 3D simulations of dendritic structures are compared with the analytical predictions of the Brener theory [Journal of Crystal Growth 99 (1990) 165-170] and with recent experimental measurements of solidification in pure nickel [Proceedings of the TMS Annual Meeting, March 14-18, 2004, pp. 277-288; European Physical Journal B, submitted for publication]. 3D morphology transitions are obtained for variations in surface energy and kinetic anisotropies at different undercoolings. In computations, we investigate the convergence behaviour of a standard phase-field model and of its thin interface extension at different undercoolings and at different ratios between the diffuse interface thickness and the atomistic capillary length. The influence of the grid anisotropy is accurately analyzed for a finite difference method and for an adaptive finite element method in comparison.

  9. TEMs but not DKK1 could serve as complementary biomarkers for AFP in diagnosing AFP-negative hepatocellular carcinoma.

    Science.gov (United States)

    Mao, Liping; Wang, Yueguo; Wang, Delin; Han, Gang; Fu, Shouzhong; Wang, Jianxin

    2017-01-01

    Hepatitis B virus (HBV)-related hepatocellular carcinoma (HCC) is prevalent worldwide. Despite its limitations, serum alpha-fetoprotein (AFP) remains the most widely-used biomarker for the diagnosis of HCC. This study aimed to assess whether measurement of peripheral plasma Dickkopf-1 (DKK1) and Tie2-expressing monocytes (TEMs) could overcome the limitations of AFP and improve the diagnostic accuracy of HCC. Plasma DKK1 level and the percentage of TEMs in peripheral CD14+CD16+ monocytes from HCC patients (n = 82), HBV-related liver cirrhosis (LC) patients (n = 29), chronic hepatitis B (CHB) infected patients (n = 28) and healthy volunteers (n = 31) were analyzed by ELISA and flow cytometry. Receiver operating characteristic (ROC) curves were used to analyze a single biomarker, or a combination of two or three biomarkers. Univariate and multivariate analyses were performed to assess the significance of each marker in prediction of HCC and AFP-negative HCC from LC patients. The percentage of TEMs in peripheral CD14+CD16+ monocytes and plasma level of DKK1 in HCC group were significantly higher than those in LC, CHB and healthy control groups (all P-values TEMs alone was also significantly higher in AFP-negative HCC group than that in LC, CHB and healthy control groups (all P-values TEMs. There was no significant difference in AUC of DKK1, TEMs and AFP in HCC diagnosis between the four groups (all P>0.05). A combination of DKK1, TEMs and AFP measurements increased the AUC for HCC diagnosis as compared with either marker alone (0.833; 95%CI 0.768-0.886). The AUC for TEMs was 0.692 (95% CI 0.564-0.819) in differentiating AFP-negative HCC from LC, with a sensitivity of 80.0% and a specificity of 65.52%. Only TEMs prevailed as a significant predictor for AFP-negative HCC differentiating from LC patients in univariate and multivariate analyses (P = 0.016, P = 0.023). TEMs and DKK1 may prove to be potential complementary biomarkers for AFP in the diagnosis of HCC. TEMs

  10. Analysis of degradation in nickel-based alloys using focused ion beam imaging and specimen preparation combined with analytical electron microscopy

    International Nuclear Information System (INIS)

    Phaneuf, M.W.; Botton, G.A.

    2002-01-01

    Focused ion beam (FIB) microscopes have become well-established in the semiconductor industry during the past decade, and are rapidly gaining attention in the field of materials science, both as a tool for producing site specific, parallel sided transmission electron microscope (TEM) specimens and as stand alone specimen preparation and imaging systems. FIB secondary electron imaging (SEI) of nickel-based alloys, such as commercially produced Alloy 600 (approximately Ni 15Cr 10Fe 0.5C), has been demonstrated to show a high degree of sensitivity to the presence of deformation in the alloy, and FIB secondary ion imaging (SII) is particularly useful for identifying the presence of grain boundary corrosion, as secondary ion yields from metallic specimens can increase by three orders of magnitude in the presence of oxygen. This 'oxygen enhanced yield', makes FIB SII ideal for detection of corrosion at grain boundaries down to thicknesses of only a few tens of nanometers. Historically, while TEM has been considered the tool of choice for high resolution chemical and crystallographic analysis of specimens, the technique has suffered from difficulties in producing suitable samples from site-specific areas with a high probability of success. The advent of FIB specimen preparation for TEM has largely changed that. FIB imaging can be combined with FIB 'nano-machining' techniques to produce site-specific, parallel sided TEM specimens well-suited to analytical electron microscopy (AEM) analyses in the TEM, including electron energy loss spectroscopy (EELS), energy dispersive x-ray spectroscopy (EDX) and electron diffraction. When combined with new FIB-based methodologies for surveying large areas to exactly select the regions of interest, such as crack tips or the maximum extent of penetration of intergranular attack (IGA), subsequent FIB TEM specimen preparation and TEM analysis unite to produce a powerful tool to study these phenomena. Examples of these applications of FIB

  11. 2.5D Modeling of TEM Data Applied to Hidrogeological Studies in PARANÁ Basin, Brazil

    Science.gov (United States)

    Bortolozo, C. A.; Porsani, J. L.; Santos, F. M.

    2013-12-01

    The transient electromagnetic method (TEM) is used all over the world and has shown great potential in hydrological, hazardous waste site characterization, mineral exploration, general geological mapping, and geophysical reconnaissance. However, the behavior of TEM fields are very complex and is not yet fully understood. Forward modeling is one of the most common and effective methods to understand the physical behavior and significance of the electromagnetics responses of a TEM sounding. Until now, there are a limited number of solutions for the 2D forward problem for TEM. More rare are the descriptions of a three-component response of a 3D source over 2D earth, which is the so-called 2.5D. The 2.5D approach is more realistic than the conventional 2D source previous used, once normally the source cannot be realistic represented for a 2D approximation (normally source are square loops). At present the 2.5D model represents the only way of interpreting TEM data in terms of a complex earth, due to the prohibitive amount of computer time and storage required for a full 3D model. In this work we developed a TEM modeling program for understanding the different responses and how the magnetic and electric fields, produced by loop sources at air-earth interface, behave in different geoelectrical distributions. The models used in the examples are proposed focusing hydrogeological studies, once the main objective of this work is for detecting different kinds of aquifers in Paraná sedimentary basin, in São Paulo State - Brazil. The program was developed in MATLAB, a widespread language very common in the scientific community.

  12. Crosstalk between TEMs and endothelial cells modulates angiogenesis and metastasis via IGF1-IGF1R signalling in epithelial ovarian cancer.

    Science.gov (United States)

    Wang, Xinjing; Zhu, Qinyi; Lin, Yingying; Wu, Li; Wu, Xiaoli; Wang, Kai; He, Qizhi; Xu, Congjian; Wan, Xiaoping; Wang, Xipeng

    2017-10-24

    Epithelial ovarian cancer (EOC) is the leading cause of death from gynaecologic malignancies and has a poor prognosis due to metastasis. Drugs targeting the angiogenesis pathway significantly improve patient outcome. However, the key factors linking angiogenesis and metastasis have not been elucidated. In this study, we found Tie2 expressing monocytes (CD14 + Tie2 + , TEMs) as key contributors to angiogenesis and metastasis of EOC. Tissue slides were evaluated by immunofluorescence for the presence of total tissue macrophages and TEMs. The correlation between microvascular density (MVD) values and the TEMs number or ratio was calculated in both ovarian cancer tissues and peritoneum. The rate of TEMs in monocytes was evaluated in the peripheral blood of female healthy donors, benign cysts patients, and EOC patients using flow cytometry. The TEMs rate in ascites from EOC patients was also evaluated by flow cytometry. The concentration of Ang2, as the ligand of Tie2, was examined by ELISA in serum samples of EOC patients, benign cysts patients, and ascites samples of EOC patients. The effects of Ang2 on the migration and the cytokine expression of TEMs were further examined. The pro- angiogenesis activity of TEMs via IGF1 was performed in both in vivo and in vitro. And the IGF1 blocking test was performed using neutralising antibody. TEMs were significantly higher in tumour foci, peripheral blood and ascites in EOC patients. The proportion of TEMs among total tissue macrophages was positively correlated with tumour MVD. In vivo animal results showed that TEMs promoted EOC angiogenesis and metastasis. Further functional and mechanisms studies revealed that concentration of angiopoietin 2 (Ang2), a ligand of Tie2, was elevated in EOC ascites which further recruit TEMs in a dose-dependent manner as a powerful chemokine to TEMs. Recruited TEMs promoted endothelial cell function through IGF1-activated downstream signalling. Blocking secreted IGF1 using inhibiting antibody

  13. Use of the TEM Cell for Compliance Testing of Emissions and Immunity, an IEC Perspective

    DEFF Research Database (Denmark)

    Bentz, Sigurd

    1996-01-01

    The current work of the IEC on preparing a standard for the use of TEM cells for compliance testing of emissions and immunity is reviewed. The requirements of TEM cells are related to the established procedures: “open area test site” and “shielded enclosure with area of uniform field”, respective...

  14. Comparison of analytic models of instability of rarefied gas flow in a channel

    Energy Technology Data Exchange (ETDEWEB)

    Aksenova, Olga A. [St.-Petersburg State University, Department of Mathematics and Mechanics, 198504, Universitetskiy pr., 28, Peterhof, St.-Petersburg (Russian Federation); Khalidov, Iskander A. [St.-Petersburg State Polytechnic University, Department of Mathematics and Mechanics, 195251, Polytechnicheskaya ul., 29, St.-Petersburg (Russian Federation)

    2014-12-09

    Numerical and analytical results are compared concerning the limit properties of the trajectories, attractors and bifurcations of rarefied gas flows in channels. The cascade of bifurcations obtained in our previous analytical and numerical investigations is simulated numerically for different scattering functions V generalizing the ray-diffuse reflection of gas particles from the surface. The main purpose of numerical simulation by Monte Carlo method is the investigation of the properties of different analytic nonlinear dynamic systems corresponding to rarefied gas flow in a channel. The results are compared as well for the models suggested originally by R. N. Miroshin, as for the approximations considered for the first time or for studied in our subsequent papers. Analytical solutions we obtained earlier for the ray reflection which means only one determined velocity of scattered from the walls gas atoms, generally different from the specular reflection. The nonlinear iterative equation describing a rarefied gas flow in a long channel becomes unstable in some regions of corresponding parameters of V (it means the sensitivity to boundary conditions). The values of the parameters are found from analytical approximations in these regions. Numerical results show that the chaotic behavior of the nonlinear dynamic system corresponds to strange attractors and distinguishes clearly from Maxwellian distribution and from the equilibrium on the whole. In the regions of instability (as the dimension of the attractor increases) the search for a corresponding state requires a lot more computation time and a lot of data (the amount of data required increases exponentially with embedding dimension). Therefore the main complication in the computation is reducing as well the computing time as the amount of data to find a suitably close solution. To reduce the computing time our analytical results are applied. Flow conditions satisfying the requirements to the experiment are

  15. Comparison of immersion density and improved microstructural characterization methods for measuring swelling in small irradiated disk specimens

    International Nuclear Information System (INIS)

    Sawai, T.; Suzuki, M.; Hishinuma, A.; Maziasz, P.J.

    1992-01-01

    The procedure of obtaining microstructural data from reactor-irradiated specimens has been carefully checked for accuracy by comparison of swelling data obtained from transmission electron microscopy (TEM) observations of cavities with density-change data measured using the Precision Densitometer at Oak Ridge National Laboratory (ORNL). Comparison of data measured by both methods on duplicate or, in some cases, on the same specimen has shown some appreciable discrepancies for US/Japan collaborative experiments irradiated in the High Flux Isotope Reactor (HFIR). The contamination spot separation (CSS) method was used in the past to determine the thickness of a TEM foil. Recent work has revealed an appreciable error in this method that can result in an overestimation of the foil thickness. This error causes lower swelling values to be measured by TEM microstructural observation relative to the Precision Densitometer. An improved method is proposed for determining the foil thickness by the CSS method, which includes a correction for the systematic overestimation of foil thickness. (orig.)

  16. Fast analytical scatter estimation using graphics processing units.

    Science.gov (United States)

    Ingleby, Harry; Lippuner, Jonas; Rickey, Daniel W; Li, Yue; Elbakri, Idris

    2015-01-01

    To develop a fast patient-specific analytical estimator of first-order Compton and Rayleigh scatter in cone-beam computed tomography, implemented using graphics processing units. The authors developed an analytical estimator for first-order Compton and Rayleigh scatter in a cone-beam computed tomography geometry. The estimator was coded using NVIDIA's CUDA environment for execution on an NVIDIA graphics processing unit. Performance of the analytical estimator was validated by comparison with high-count Monte Carlo simulations for two different numerical phantoms. Monoenergetic analytical simulations were compared with monoenergetic and polyenergetic Monte Carlo simulations. Analytical and Monte Carlo scatter estimates were compared both qualitatively, from visual inspection of images and profiles, and quantitatively, using a scaled root-mean-square difference metric. Reconstruction of simulated cone-beam projection data of an anthropomorphic breast phantom illustrated the potential of this method as a component of a scatter correction algorithm. The monoenergetic analytical and Monte Carlo scatter estimates showed very good agreement. The monoenergetic analytical estimates showed good agreement for Compton single scatter and reasonable agreement for Rayleigh single scatter when compared with polyenergetic Monte Carlo estimates. For a voxelized phantom with dimensions 128 × 128 × 128 voxels and a detector with 256 × 256 pixels, the analytical estimator required 669 seconds for a single projection, using a single NVIDIA 9800 GX2 video card. Accounting for first order scatter in cone-beam image reconstruction improves the contrast to noise ratio of the reconstructed images. The analytical scatter estimator, implemented using graphics processing units, provides rapid and accurate estimates of single scatter and with further acceleration and a method to account for multiple scatter may be useful for practical scatter correction schemes.

  17. TEM studies of P+ implanted and subsequently laser annealed Si

    International Nuclear Information System (INIS)

    Sadana, D.K.; Wilson, M.C.; Booker, G.R.; Washburn, J.

    1979-05-01

    The present investigation is concerned with laser annealing of P + implanted Si. The aim of the work was to study the crystallization behavior of damage structure occurring due to high dose rate implantation using transmission electron microscopy (TEM) as the method of examination

  18. Strain study of gold nanomaterials as HR-TEM calibration standard.

    Science.gov (United States)

    Peng, X Y; Zhou, L Q; Li, X; Tao, X F; Ren, L L; Cao, W H; Xu, G F

    2015-12-01

    This work presents the use of high resolution electron microscopy (HREM) and geometric phase analysis (GPA) to measure the interplanar spacing and strain distribution of three gold nanomaterials, respectively. The results showed that the {111} strain was smaller than the {002} strain for any kind of gold materials at the condition of same measuring method. The 0.65% of {111} strain in gold film measured by HREM (0.26% measured by GPA) was smaller than the {111} strains in two gold particles. The presence of lattice strain was interpreted according to the growth mechanism of metallic thin film. It is deduced that the {111} interplanar spacing of the gold thin film is suitable for high magnification calibration of transmission electron microscopy (TEM) and the gold film is potential to be a new calibration standard of TEM. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. A Unified Channel Charges Expression for Analytic MOSFET Modeling

    Directory of Open Access Journals (Sweden)

    Hugues Murray

    2012-01-01

    Full Text Available Based on a 1D Poissons equation resolution, we present an analytic model of inversion charges allowing calculation of the drain current and transconductance in the Metal Oxide Semiconductor Field Effect Transistor. The drain current and transconductance are described by analytical functions including mobility corrections and short channel effects (CLM, DIBL. The comparison with the Pao-Sah integral shows excellent accuracy of the model in all inversion modes from strong to weak inversion in submicronics MOSFET. All calculations are encoded with a simple C program and give instantaneous results that provide an efficient tool for microelectronics users.

  20. Thermodynamics of Gas Turbine Cycles with Analytic Derivatives in OpenMDAO

    Science.gov (United States)

    Gray, Justin; Chin, Jeffrey; Hearn, Tristan; Hendricks, Eric; Lavelle, Thomas; Martins, Joaquim R. R. A.

    2016-01-01

    A new equilibrium thermodynamics analysis tool was built based on the CEA method using the OpenMDAO framework. The new tool provides forward and adjoint analytic derivatives for use with gradient based optimization algorithms. The new tool was validated against the original CEA code to ensure an accurate analysis and the analytic derivatives were validated against finite-difference approximations. Performance comparisons between analytic and finite difference methods showed a significant speed advantage for the analytic methods. To further test the new analysis tool, a sample optimization was performed to find the optimal air-fuel equivalence ratio, , maximizing combustion temperature for a range of different pressures. Collectively, the results demonstrate the viability of the new tool to serve as the thermodynamic backbone for future work on a full propulsion modeling tool.

  1. Design Evaluation of Wind Turbine Spline Couplings Using an Analytical Model: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Y.; Keller, J.; Wallen, R.; Errichello, R.; Halse, C.; Lambert, S.

    2015-02-01

    Articulated splines are commonly used in the planetary stage of wind turbine gearboxes for transmitting the driving torque and improving load sharing. Direct measurement of spline loads and performance is extremely challenging because of limited accessibility. This paper presents an analytical model for the analysis of articulated spline coupling designs. For a given torque and shaft misalignment, this analytical model quickly yields insights into relationships between the spline design parameters and resulting loads; bending, contact, and shear stresses; and safety factors considering various heat treatment methods. Comparisons of this analytical model against previously published computational approaches are also presented.

  2. Analytic and numerical realizations of a disc galaxy

    Science.gov (United States)

    Stringer, M. J.; Brooks, A. M.; Benson, A. J.; Governato, F.

    2010-09-01

    Recent focus on the importance of cold, unshocked gas accretion in galaxy formation - not explicitly included in semi-analytic studies - motivates the following detailed comparison between two inherently different modelling techniques: direct hydrodynamical simulation and semi-analytic modelling. By analysing the physical assumptions built into the GASOLINE simulation, formulae for the emergent behaviour are derived which allow immediate and accurate translation of these assumptions to the GALFORM semi-analytic model. The simulated halo merger history is then extracted and evolved using these equivalent equations, predicting a strikingly similar galactic system. This exercise demonstrates that it is the initial conditions and physical assumptions which are responsible for the predicted evolution, not the choice of modelling technique. On this level playing field, a previously published GALFORM model is applied (including additional physics such as chemical enrichment and feedback from active galactic nuclei) which leads to starkly different predictions.

  3. Substrate-HTcS thin film interaction studies by (S)TEM

    NARCIS (Netherlands)

    Ramaekers, P.P.J.; Klepper, D.; Kitazawa, K.; Ishiguro, T.

    1989-01-01

    This paper concerns with compatibility aspects beween HTcS thin film either their substrates. The influence of substrate-thin film interaction and thin film microstructure on the superconducting properties is discussed. In this respect, data based on (S)TEM observations are presented. It is

  4. Novel Transrotational Solid State Order Discovered by TEM in Crystallizing Amorphous Films

    Science.gov (United States)

    Kolosov, Vladimir

    Exotic thin crystals with unexpected transrotational microstructures have been discovered by transmission electron microscopy (TEM) for crystal growth in thin (10-100 nm) amorphous films of different chemical nature (oxides, chalcogenides, metals and alloys) prepared by various methods. Primarily we use our TEM bend contour technique. The unusual phenomenon can be traced in situ in TEM column: dislocation independent regular internal bending of crystal lattice planes in a growing crystal. Such transrotation (unit cell trans lation is complicated by small rotationrealized round an axis lying in the film plane) can result in strong regular lattice orientation gradients (up to 300 degrees per micrometer) of different geometries: cylindrical, ellipsoidal, toroidal, saddle, etc. Transrotation is increasing as the film gets thinner. Transrotational crystal resembles ideal single crystal enclosed in a curved space. Transrotational micro crystals have been eventually recognized by other authors in some vital thin film materials, i.e. PCMs for memory, silicides, SrTiO3. Atomic model and possible mechanisms of the phenomenon are discussed. New transrotational nanocrystalline model of amorphous state is also proposed Support of RF Ministry of Education and Science is acknowledged.

  5. Scalable pumping approach for extracting the maximum TEM(00) solar laser power.

    Science.gov (United States)

    Liang, Dawei; Almeida, Joana; Vistas, Cláudia R

    2014-10-20

    A scalable TEM(00) solar laser pumping approach is composed of four pairs of first-stage Fresnel lens-folding mirror collectors, four fused-silica secondary concentrators with light guides of rectangular cross-section for radiation homogenization, four hollow two-dimensional compound parabolic concentrators for further concentration of uniform radiations from the light guides to a 3 mm diameter, 76 mm length Nd:YAG rod within four V-shaped pumping cavities. An asymmetric resonator ensures an efficient large-mode matching between pump light and oscillating laser light. Laser power of 59.1 W TEM(00) is calculated by ZEMAX and LASCAD numerical analysis, revealing 20 times improvement in brightness figure of merit.

  6. Analytical and pre-analytical performance characteristics of a novel cartridge-type blood gas analyzer for point-of-care and laboratory testing.

    Science.gov (United States)

    Oyaert, Matthijs; Van Maerken, Tom; Bridts, Silke; Van Loon, Silvi; Laverge, Heleen; Stove, Veronique

    2018-03-01

    Point-of-care blood gas test results may benefit therapeutic decision making by their immediate impact on patient care. We evaluated the (pre-)analytical performance of a novel cartridge-type blood gas analyzer, the GEM Premier 5000 (Werfen), for the determination of pH, partial carbon dioxide pressure (pCO 2 ), partial oxygen pressure (pO 2 ), sodium (Na + ), potassium (K + ), chloride (Cl - ), ionized calcium ( i Ca 2+ ), glucose, lactate, and total hemoglobin (tHb). Total imprecision was estimated according to the CLSI EP5-A2 protocol. The estimated total error was calculated based on the mean of the range claimed by the manufacturer. Based on the CLSI EP9-A2 evaluation protocol, a method comparison with the Siemens RapidPoint 500 and Abbott i-STAT CG8+ was performed. Obtained data were compared against preset quality specifications. Interference of potential pre-analytical confounders on co-oximetry and electrolyte concentrations were studied. The analytical performance was acceptable for all parameters tested. Method comparison demonstrated good agreement to the RapidPoint 500 and i-STAT CG8+, except for some parameters (RapidPoint 500: pCO 2 , K + , lactate and tHb; i-STAT CG8+: pO 2 , Na + , i Ca 2+ and tHb) for which significant differences between analyzers were recorded. No interference of lipemia or methylene blue on CO-oximetry results was found. On the contrary, significant interference for benzalkonium and hemolysis on electrolyte measurements were found, for which the user is notified by an interferent specific flag. Identification of sample errors from pre-analytical sources, such as interferences and automatic corrective actions, along with the analytical performance, ease of use and low maintenance time of the instrument, makes the evaluated instrument a suitable blood gas analyzer for both POCT and laboratory use. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. Practical aspects and trends in analytical organic mass spectrometry

    International Nuclear Information System (INIS)

    Schlunegger, U.P.

    1981-01-01

    Proceeding from the fundamentals of mass spectrometry (MS), some more recent developments of analytical organic MS are shown in comparison with conventional MS. Sections are headed: the vacuum, production of ions in the mass spectrometer, ions in the analyzer of a mass spectrometer, general considerations, practice of modern MS: selected examples

  8. An analytical statistical approach to the 3D reconstruction problem

    Energy Technology Data Exchange (ETDEWEB)

    Cierniak, Robert [Czestochowa Univ. of Technology (Poland). Inst. of Computer Engineering

    2011-07-01

    The presented here approach is concerned with the reconstruction problem for 3D spiral X-ray tomography. The reconstruction problem is formulated taking into considerations the statistical properties of signals obtained in X-ray CT. Additinally, image processing performed in our approach is involved in analytical methodology. This conception significantly improves quality of the obtained after reconstruction images and decreases the complexity of the reconstruction problem in comparison with other approaches. Computer simulations proved that schematically described here reconstruction algorithm outperforms conventional analytical methods in obtained image quality. (orig.)

  9. TEM Imaging of Mass-selected Polymer Molecules

    International Nuclear Information System (INIS)

    Nasibulin, Albert G.; Kauppinen, Esko I.; Thomson, Bruce A.; Fernandez de la Mora, J.

    2002-01-01

    Polyethylene glycol (PEG) molecules with masses below 1300 amu are electrosprayed (ES) from solution, mobility-selected at high resolution in a differential mobility analyzer (DMA), collected on a grid and imaged by transmission electron microscopy (ES-DMA-TEM). The DMA resolves individual n-mers, and selects only one out of the many present in the original sample. Ion identity is established from parallel mass spectra (ES-MS). The images reveal spherical particles 1.46 nm in diameter, in good agreement with the known ion mass and bulk density. The DMA-selection technique opens new paths for the study of very small particles

  10. Visualization of arrangements of carbon atoms in graphene layers by Raman mapping and atomic-resolution TEM

    KAUST Repository

    Cong, Chunxiao

    2013-02-01

    In-plane and out-of-plane arrangements of carbon atoms in graphene layers play critical roles in the fundamental physics and practical applications of these novel two-dimensional materials. Here, we report initial results on the edge/crystal orientations and stacking orders of bi-and tri-layer graphene (BLG and TLG) from Raman spectroscopy and transmission electron microscopy (TEM) experiments performed on the same sample. We introduce a new method of transferring graphene flakes onto a normal TEM grid. Using this novel method, we probed the BLG and TLG flakes that had been previously investigated by Raman scattering with high-resolution (atomic) TEM.

  11. A comparison of galaxy group luminosity functions from semi-analytic models

    NARCIS (Netherlands)

    Snaith, Owain N.; Gibson, Brad K.; Brook, Chris B.; Courty, Stéphanie; Sánchez-Blázquez, Patricia; Kawata, Daisuke; Knebe, Alexander; Sales, Laura V.

    Semi-analytic models (SAMs) are currently one of the primary tools with which we model statistically significant ensembles of galaxies. The underlying physical prescriptions inherent to each SAM are, in many cases, different from one another. Several SAMs have been applied to the dark matter merger

  12. Review and evaluation of spark source mass spectrometry as an analytical method

    International Nuclear Information System (INIS)

    Beske, H.E.

    1981-01-01

    The analytical features and most important fields of application of spark source mass spectrometry are described with respect to the trace analysis of high-purity materials and the multielement analysis of technical alloys, geochemical and cosmochemical, biological and radioactive materials, as well as in environmental analysis. Comparisons are made to other analytical methods. The distribution of the method as well as opportunities for contract analysis are indicated and developmental tendencies discussed. (orig.) [de

  13. ANALISIS KUAT SINYAL DAN KUALITAS PANGGILAN JARINGAN GSM INDOOR DENGAN TEMS INVESTIGATION DAN G-NETTRACK PRO

    Directory of Open Access Journals (Sweden)

    Ida Bagus Ari Budiarta

    2016-03-01

    Full Text Available Kebutuhan akan teknologi GSM merupakan tantangan bagi provider untuk memberikan pelayanan terbaik bagi pengguna layanannya. Dalam proses layanan tersebut kemungkinan besar terdapat masalah yang terjadi. Pihak provider biasanya melakukan walk test untuk mengecek kekuatan sinyal yang dipancarkan oleh antena pemancar di dalam ruangan. Kebanyakan pihak provider menggunakan TEMS Investigation dalam melakukan walk test. Biaya walk test dengan TEMS Investigation bisa dikatakan cukup mahal. Namun dengan berkembangnya teknologi, walk test juga bisa dilakukan menggunakan smartphone Android dengan menggunakan G-NetTrack Pro. Dalam penelitian ini dibandingkan kualitas hasil pengukuran parameter kuat sinyal yaitu RSL dan parameter kualitas panggilan yaitu RxQual, CSSR, dan DCR antara software TEMS Investigation dengan G-NetTrack Pro berdasarkan metode walk test pada jaringan GSM indoor 1800 MHz di Matahari Duta Plaza. Secara keseluruhan, G-NetTrack Pro mampu menampilkan data yang dibutuhkan pada penelitian tetapi tidak sedetail TEMS Investigation, sehingga untuk pengenalan awal walk test, software G-NetTrack Pro bisa digunakan sebagai bahan pembelajaran.

  14. Comparison of a semi-analytic and a CFD model uranium combustion to experimental data

    International Nuclear Information System (INIS)

    Clarksean, R.

    1998-01-01

    Two numerical models were developed and compared for the analysis of uranium combustion and ignition in a furnace. Both a semi-analytical solution and a computational fluid dynamics (CFD) numerical solution were obtained. Prediction of uranium oxidation rates is important for fuel storage applications, fuel processing, and the development of spent fuel metal waste forms. The semi-analytical model was based on heat transfer correlations, a semi-analytical model of flow over a flat surface, and simple radiative heat transfer from the material surface. The CFD model numerically determined the flowfield over the object of interest, calculated the heat and mass transfer to the material of interest, and calculated the radiative heat exchange of the material with the furnace. The semi-analytical model is much less detailed than the CFD model, but yields reasonable results and assists in understanding the physical process. Short computation times allowed the analyst to study numerous scenarios. The CFD model had significantly longer run times, was found to have some physical limitations that were not easily modified, but was better able to yield details of the heat and mass transfer and flow field once code limitations were overcome

  15. In situ oxidation of zirconium binary alloys by environmental SEM and analysis by AFM, FIB, and TEM

    International Nuclear Information System (INIS)

    Proff, C.; Abolhassani, S.; Dadras, M.M.; Lemaignan, C.

    2010-01-01

    Binary Zr-alloys containing 1%Fe and 1% Ni (large precipitates) and 1% Cr and 0.6% Nb (small precipitates), as well as a pure Zr sample were exposed in situ at 130 Pa water vapour pressure at 415 o C in an environmental SEM. The surface topography and composition of each sample was characterised before in situ experiments, during and after oxidation. After oxidation the surface was characterised by SEM and EDS, AFM and TEM combined with EDS. Focused ion beam was used to prepare cross sections of the metal-oxide interface and for the preparation of TEM thin foils. The oxidation behaviour of precipitates for these alloying elements can be characterised into two large families, those which show a rapid oxidation and those which induce a delayed oxidation in comparison with the Zr-matrix. At 415 o C after 1 h of oxidation for Zr1%Fe and Zr1%Ni, the formation of protrusions could be detected at the surface, being related to underlying SPP in the oxide. On Zr1%Cr and Zr0.6%Nb unoxidised SPPs were observed in the oxide, close to the metal-oxide interface. These SPPs were, however, oxidised close to the outer surface of the oxide. The surface roughness was increased for all materials after in situ oxidation, however, only for Zr1%Fe and Zr1%Ni protrusions appeared on the surface during oxidation. It was subsequently demonstrated that these latter correspond to the position of SPPs. For Zr1%Fe the surface roughness increased more than in the other materials and on these protrusions small iron oxide crystals have been observed at the surface. These observations confirm that Fe has a different behaviour compared to the other SPP forming elements, and it diffuses out to the free surface of the material. These alloying elements being the constituents of the commercial alloys (Fe and Cr for Zircaloy-4; Fe, Cr and Ni for Zircaloy-2 and Nb for all Nb-containing alloys), this study allows to separate their individual influence and can allow a subsequent comparison to the behaviour

  16. On the structural affinity of macromolecules with different biological properties: Molecular dynamics simulations of a series of TEM-1 mutants

    Energy Technology Data Exchange (ETDEWEB)

    Giampaolo, Alessia Di [Dipartimento di Scienze Fisiche e Chimiche, Universita’ degli Studi di l’Aquila, Via Vetoio snc, 67100 Coppito (AQ) (Italy); Mazza, Fernando [Department of Health Sciences, Univ. of L’Aquila, 67010 L’Aquila (Italy); Daidone, Isabella [Dipartimento di Scienze Fisiche e Chimiche, Universita’ degli Studi di l’Aquila, Via Vetoio snc, 67100 Coppito (AQ) (Italy); Amicosante, Gianfranco; Perilli, Mariagrazia [Dipartimento di Scienze Cliniche Applicate e Biotecnologiche, Università degli Studi di l’Aquila, Via Vetoio snc, 67100 Coppito (AQ) (Italy); Aschi, Massimiliano, E-mail: massimiliano.aschi@univaq.it [Dipartimento di Scienze Fisiche e Chimiche, Universita’ degli Studi di l’Aquila, Via Vetoio snc, 67100 Coppito (AQ) (Italy)

    2013-07-12

    Highlights: •We have performed molecular dynamics simulations of TEM-1 mutants. •Mutations effects on the mechanical properties are considered. •Mutants do not significantly alter the average enzymes structure. •Mutants produce sharp alterations in enzyme conformational repertoire. •Mutants also produce changes in the active site volume. -- Abstract: Molecular Dynamics simulations have been carried out in order to provide a molecular rationalization of the biological and thermodynamic differences observed for a class of TEM β-lactamases. In particular we have considered the TEM-1(wt), the single point mutants TEM-40 and TEM-19 representative of IRT and ESBL classes respectively, and TEM-1 mutant M182T, TEM-32 and TEM-20 which differ from the first three for the additional of M182T mutation. Results indicate that most of the thermodynamic, and probably biological behaviour of these systems arise from subtle effects which, starting from the alterations of the local interactions, produce drastic modifications of the conformational space spanned by the enzymes. The present study suggests that systems showing essentially the same secondary and tertiary structure may differentiate their chemical–biological activity essentially (and probably exclusively) on the basis of the thermal fluctuations occurring in their physiological environment.

  17. On the structural affinity of macromolecules with different biological properties: Molecular dynamics simulations of a series of TEM-1 mutants

    International Nuclear Information System (INIS)

    Giampaolo, Alessia Di; Mazza, Fernando; Daidone, Isabella; Amicosante, Gianfranco; Perilli, Mariagrazia; Aschi, Massimiliano

    2013-01-01

    Highlights: •We have performed molecular dynamics simulations of TEM-1 mutants. •Mutations effects on the mechanical properties are considered. •Mutants do not significantly alter the average enzymes structure. •Mutants produce sharp alterations in enzyme conformational repertoire. •Mutants also produce changes in the active site volume. -- Abstract: Molecular Dynamics simulations have been carried out in order to provide a molecular rationalization of the biological and thermodynamic differences observed for a class of TEM β-lactamases. In particular we have considered the TEM-1(wt), the single point mutants TEM-40 and TEM-19 representative of IRT and ESBL classes respectively, and TEM-1 mutant M182T, TEM-32 and TEM-20 which differ from the first three for the additional of M182T mutation. Results indicate that most of the thermodynamic, and probably biological behaviour of these systems arise from subtle effects which, starting from the alterations of the local interactions, produce drastic modifications of the conformational space spanned by the enzymes. The present study suggests that systems showing essentially the same secondary and tertiary structure may differentiate their chemical–biological activity essentially (and probably exclusively) on the basis of the thermal fluctuations occurring in their physiological environment

  18. ANALISIS JARINGAN UMTS PADA MENARA ROOFTOP DENGAN MENGGUNAKAN SOFTWARE TEMS INVESTIGATION DAN G-NETTRACK PRO

    OpenAIRE

    Pande Putu Wahyu Pramanda; Pande Ketut Sudiarta; Ngurah Indra ER.

    2016-01-01

    Berkembangnya dunia teknologi telekomunikasi dan informasi sejalan dengan kebutuhan akan kecepatan dan kestabilan akses internet teknologi UMTS. Metode drive test adalah metode yang biasanya digunakan untuk pengukuran kualitas sebuah site. Pihak provider umumnya menggunakan software TEMS Investigation dalam melakukan drive test. Melakukan drive test dengan TEMS Investigation sangatlah tidak praktis dan memerlukan biaya yang besar. Berkembangnya teknologi smartphone membuat drive test dapat di...

  19. Behaviour of TEM metal grids during in-situ heating experiments.

    Science.gov (United States)

    Zhang, Zaoli; Su, Dangsheng

    2009-05-01

    The stability of Ni, Cu, Mo and Au transmission electron microscope (TEM) grids coated with ultra-thin amorphous carbon (alpha-C) or silicon monoxide film is examined by in-situ heating up to a temperature in the range 500-850 degrees C in a transmission electron microscope. It is demonstrated that some grids can generate nano-particles either due to the surface diffusion of metal atoms on amorphous film or due to the metal evaporation/redeposition. The emergence of nano-particles can complicate experimental observations, particularly in in-situ heating studies of dynamic behaviours of nano-materials in TEM. The most widely used Cu grid covered with amorphous carbon is unstable, and numerous Cu nano-particles start to form once the heating temperature reaches 600 degrees C. In the case of Ni grid covered with alpha-C film, a large number of Ni nano-crystals occur immediately when the temperature approaches 600 degrees C, accompanied by the graphitization of amorphous carbon. In contrast, both Mo and Au grids covered with alpha-C film exhibit good stability at elevated temperature, for instance, up to 680 and 850 degrees C for Mo and Au, respectively, and any other metal nano-particles are detected. Cu grid covered Si monoxide thin film is stable up to 550 degrees C, but Si nano-crystals appear under intensive electron beam. The generated nano-particles are well characterized by spectroscopic techniques (EDXS/EELS) and high-resolution TEM. The mechanism of nano-particle formation is addressed based on the interactions between the metal grid and the amorphous carbon film and on the sublimation of metal.

  20. Development and ITER relevant application of a user friendly interface (TEM) for use with the TMAP4 code

    International Nuclear Information System (INIS)

    Tanaka, M.R.; Fong, C.; Kalyanam, K.M.; Sood, S.K.; Delisle, M.; Natalizio, A.

    1995-01-01

    The Tritium Enclosure Model (TEM) has been developed as a user friendly interface to facilitate the application of the previously validated, verified and ITER approved TMAP4 Code. TEM (and TMAP4) dynamically analyzes the movement of tritium through structures, between structures and adjoining enclosures. Credible ITER relevant accident scenarios were developed and analyzed. The analyses considered the scenario with the cleanup system active or inactive, with and without the surface interactions. For surface interaction cases, the epoxy characteristics reported in the TMAP4 User Manual were used. Typical applications for TEM are the estimation of time-dependent tritium inventories in enclosures, as well as emissions to the environment following an accidental spill into any set of enclosures connected to cleanup systems. This paper outlines the various features of TEM and reports on the application of TEM to determine environmental source terms for the ITER Fuel Cycle and Cooling Systems, under chronic and accidental tritium releases. 3 refs., 2 figs., 1 tab

  1. TEM in situ micropillar compression tests of ion irradiated oxide dispersion strengthened alloy

    Energy Technology Data Exchange (ETDEWEB)

    Yano, K.H., E-mail: kaylayano@u.boisestate.edu [Boise State University, 1910 University Drive, Boise, ID, 83725 (United States); Swenson, M.J. [Boise State University, 1910 University Drive, Boise, ID, 83725 (United States); Wu, Y. [Boise State University, 1910 University Drive, Boise, ID, 83725 (United States); Center for Advanced Energy Studies, 995 University Blvd, Idaho Falls, ID, 83401 (United States); Wharry, J.P. [Boise State University, 1910 University Drive, Boise, ID, 83725 (United States); Purdue University, 400 Central Drive, West Lafayette, IN 47907 (United States)

    2017-01-15

    The growing role of charged particle irradiation in the evaluation of nuclear reactor candidate materials requires the development of novel methods to assess mechanical properties in near-surface irradiation damage layers just a few micrometers thick. In situ transmission electron microscopic (TEM) mechanical testing is one such promising method. In this work, microcompression pillars are fabricated from a Fe{sup 2+} ion irradiated bulk specimen of a model Fe-9%Cr oxide dispersion strengthened (ODS) alloy. Yield strengths measured directly from TEM in situ compression tests are within expected values, and are consistent with predictions based on the irradiated microstructure. Measured elastic modulus values, once adjusted for the amount of deformation and deflection in the base material, are also within the expected range. A pillar size effect is only observed in samples with minimum dimension ≤100 nm due to the low inter-obstacle spacing in the as received and irradiated material. TEM in situ micropillar compression tests hold great promise for quantitatively determining mechanical properties of shallow ion-irradiated layers.

  2. Vibrational spectroscopy and analytical electron microscopy studies of Fe-V-O and In-V-O thin films

    CERN Document Server

    Vuk, A S; Drazic, G; Colomban, P

    2002-01-01

    Orthovanadate (M sup 3 sup + VO sub 4; M= Fe, In) and vanadate (Fe sub 2 V sub 4 O sub 1 sub 3) thin films were prepared using sol-gel synthesis and dip coating deposition. Using analytical electron microscopy (AEM), the chemical composition and the degree of crystallization of the phases present in the thin Fe-V-O films were investigated. TEM samples were prepared in both orientations: parallel (plan view) and perpendicular (cross section) to the substrate. In the first stages of crystallization, when the particle sizes were in the nanometer range, the classical identification of phases using electron diffraction was not possible. Instead of measuring d values, experimentally selected area electron diffraction (SAED) patterns were compared to calculated (simulated) patterns in order to determine the phase composition. The problems of evaluating the ratio of amorphous and crystalline phases in thin films are reported. Results of TEM and XRD as well as IR and Raman spectroscopy showed that the films made at lo...

  3. Optimized pre-thinning procedures of ion-beam thinning for TEM sample preparation by magnetorheological polishing.

    Science.gov (United States)

    Luo, Hu; Yin, Shaohui; Zhang, Guanhua; Liu, Chunhui; Tang, Qingchun; Guo, Meijian

    2017-10-01

    Ion-beam-thinning is a well-established sample preparation technique for transmission electron microscopy (TEM), but tedious procedures and labor consuming pre-thinning could seriously reduce its efficiency. In this work, we present a simple pre-thinning technique by using magnetorheological (MR) polishing to replace manual lapping and dimpling, and demonstrate the successful preparation of electron-transparent single crystal silicon samples after MR polishing and single-sided ion milling. Dimples pre-thinned to less than 30 microns and with little mechanical surface damage were repeatedly produced under optimized MR polishing conditions. Samples pre-thinned by both MR polishing and traditional technique were ion-beam thinned from the rear side until perforation, and then observed by optical microscopy and TEM. The results show that the specimen pre-thinned by MR technique was free from dimpling related defects, which were still residual in sample pre-thinned by conventional technique. Nice high-resolution TEM images could be acquired after MR polishing and one side ion-thinning. MR polishing promises to be an adaptable and efficient method for pre-thinning in preparation of TEM specimens, especially for brittle ceramics. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Pro-angiogenic TIE-2-expressing monocytes/TEMs as a biomarker of the effect of sorafenib in patients with advanced hepatocellular carcinoma.

    Science.gov (United States)

    Shoji, Hirotaka; Yoshio, Sachiyo; Mano, Yohei; Doi, Hiroyoshi; Sugiyama, Masaya; Osawa, Yosuke; Kimura, Kiminori; Arai, Taeang; Itokawa, Norio; Atsukawa, Masanori; Aoki, Yoshihiko; Fukai, Moto; Taketomi, Akinobu; Mizokami, Masashi; Kanto, Tatsuya

    2017-09-01

    Sorafenib, a multi-kinase inhibitor, inhibits tumor angiogenesis and is the first-line systemic therapy for patients with advanced hepatocellular carcinoma (HCC). However, due to its limited effects and frequent occurrence of side effects, biomarkers are needed to predict the effects of sorafenib. We considered the possibility of using TIE-2-expressing monocytes (TEMs) to predict the response in sorafenib-treated patients with advanced HCC. TEMs serve as a diagnostic marker of HCC and are related to angiogenesis. We analyzed 25 advanced HCC patients and prospectively evaluated TEMs before (Pre TEMs) and at 1 month after initial therapy (T1m TEMs). The radiologic response was evaluated by modified Response Evaluation Criteria in Solid Tumors (mRECIST). Median survival time (MST) was significantly longer in the partial response/stable disease (PR/SD) group (21.8 months) than in the PD group (8.7 months). ΔTEMs (changes of T1m TEMs compared to Pre TEMs) were significantly lower in the PR/SD group than in the PD group. MST of the ΔTEMs low group (14.2 months) was significantly longer than that of the high group (8.7 months). Univariate and multivariate Cox regression analyses showed that ΔTEMs [hazard ratio (HR) = 8.53, 95% confidence interval (CI) = 1.51-48.16, p = 0.015] and Child-Pugh class (HR = 5.59, 95% CI = 1.06-29.63, p = 0.043) were independently associated with overall survival. Our results suggest that ΔTEMs could serve as a biomarker for predicting radiologic response and overall survival in sorafenib-treated patients with advanced HCC. © 2017 UICC.

  5. Analytical Electron Diffraction from Iii-V and II-Vi Semiconductors

    Science.gov (United States)

    Spellward, Paul

    Available from UMI in association with The British Library. This thesis describes the development and evaluation of a number of new TEM-based techniques for the measurement of composition in ternary III-V and II-VI semiconductors. New methods of polarity determination in binary and ternary compounds are also presented. The theory of high energy electron diffraction is outlined, with particular emphasis on zone axis diffraction from well-defined strings. An account of TEM microstructural studies of Cd_{rm x}Hg _{rm 1-x}Te and CdTe epitaxial layers, which provided the impetus for developing the diffraction-based analytical techniques, is given. The wide range of TEM-based compositional determination techniques is described. The use of HOLZ deficiency lines to infer composition from a lattice parameter measurement is evaluated. In the case of Cd_{ rm x}Hg_{rm 1-x}Te, it is found to be inferior to other techniques developed. Studies of dynamical aspects of HOLZ diffraction can yield information about the dispersion surface from which a measure of composition may be obtained. This technique is evaluated for Al_{rm x}Ga_{rm 1-x} As, in which it is found to be of some use, and for Cd_{rm x}Hg _{rm 1-x}Te, in which the large Debye-Waller factor associated with mercury in discovered to render the method of little value. A number of critical voltages may be measured in medium voltage TEMs. The (111) zone axis critical voltage of Cd_{rm x}Hg _{rm 1-x}Te is found to vary significantly with x and forms the basis of an accurate technique for composition measurement in that ternary compound. Other critical voltage phenomena are investigated. In Al _{rm x}Ga_ {rm 1-x}As and other light ternaries, a non-systematic critical voltage is found to vary with x, providing a good indicator of composition. Critical voltage measurements may be made by conventional CBED or by various other techniques, which may also simultaneously yield information on the spatial variation of composition. The

  6. Scattering of a TEM wave from a time varying surface

    Science.gov (United States)

    Elcrat, Alan R.; Harder, T. Mark; Stonebraker, John T.

    1990-03-01

    A solution is given for reflection of a plane wave with TEM polarization from a planar surface with time varying properties. These properties are given in terms of the currents on the surface. The solution is obtained by numerically solving a system of differential-delay equations in the time domain.

  7. A survey on platforms for big data analytics.

    Science.gov (United States)

    Singh, Dilpreet; Reddy, Chandan K

    The primary purpose of this paper is to provide an in-depth analysis of different platforms available for performing big data analytics. This paper surveys different hardware platforms available for big data analytics and assesses the advantages and drawbacks of each of these platforms based on various metrics such as scalability, data I/O rate, fault tolerance, real-time processing, data size supported and iterative task support. In addition to the hardware, a detailed description of the software frameworks used within each of these platforms is also discussed along with their strengths and drawbacks. Some of the critical characteristics described here can potentially aid the readers in making an informed decision about the right choice of platforms depending on their computational needs. Using a star ratings table, a rigorous qualitative comparison between different platforms is also discussed for each of the six characteristics that are critical for the algorithms of big data analytics. In order to provide more insights into the effectiveness of each of the platform in the context of big data analytics, specific implementation level details of the widely used k-means clustering algorithm on various platforms are also described in the form pseudocode.

  8. Comparison of analytical charge-form and equilibrium thermodynamic speciation of certain radionuclides

    International Nuclear Information System (INIS)

    Jenne, E.A.; Cowan, C.E.; Robertson, D.E.

    1984-01-01

    Calculating trace element speciation with a thermodynamic model is often challenged on the basis that the existing thermodynamic data are not sufficiently reliable. Water quality data and corresponding analytical charge-form speciation analysis were available for radionuclides occurring in a low-level radioactive groundwater. This offered an opportunity for comparing the results of an equilibrium thermodynamic model with the results of analytical charge-form speciation. The charge-form speciation was determined using the Battelle Large Volume Water Sampler, which contains consecutive layers of cation resin, anion resin and activated aluminum oxide for retention of cationic, anionic and non-ionic dissolved chemical species, respectively. The thermodynamic speciation of Cs, Cr, Fe, I, Mn, Mo, Na, and Zn was calculated using the MINTEQ geochemical model. Ce, Co, Tc, Np, Pm, and Sb were speciated by hand calculation. Excellent agreement between the analytically determined charge-form and the thermodynamic speciation was observed for 54 Mn, 144 Ce, 131 I, 24 Na, 137 Cs, 99 Mo, 99 Tc, 151 Pm, 239 Np. Organic complexation by natural and/or synthetic organics in the waters may be important in the speciation of 65 An, 60 Co, 131 I, 59 Fe and possibly 51 Cr. Both 124 Sb and 125 Sb appeared to be in redox disequilibria with the groundwater. 29 references, 2 tables

  9. TOPICAL REVIEW: Present status and future prospects of spherical aberration corrected TEM/STEM for study of nanomaterials

    Directory of Open Access Journals (Sweden)

    Nobuo Tanaka

    2008-01-01

    Full Text Available The present status of Cs-corrected TEM/STEM is described from the viewpoint of the observation of nanomaterials. Characteristic features in TEM and STEM are explained using the experimental data obtained by our group and other research groups. Cs correction up to the 3rd-order aberration of an objective lens has already been established and research interest is focused on correcting the 5th-order spherical aberration and the chromatic aberration in combination with the development of a monochromator below an electron gun for smaller point-to-point resolution in optics. Another fundamental area of interest is the limitation of TEM and STEM resolution from the viewpoint of the scattering of electrons in crystals. The minimum size of the exit-wave function below samples undergoing TEM imaging is determined from the calculation of scattering around related atomic columns in the crystals. STEM does not have this limitation because the resolution is, in principle, determined by the probe size. One of the future prospects of Cs-corrected TEM/STEM is the possibility of extending the space around the sample holder by correcting the chromatic and spherical aberrations. This wider space will contribute to the ease of performing in situ experiments and various combinations of TEM and other analysis methods. High-resolution, in situ dynamic and 3D observations/analysis are the most important keywords in the next decade of high-resolution electron microscopy.

  10. Present analytical possibilities in prompt γ-ray spectrometry with charged projectiles

    International Nuclear Information System (INIS)

    Borderie, B.

    1980-01-01

    This review article deals with γ-rays following bombardment by charged projectiles and the use of this process as an analytical method. A general enumeration of analytical possibilities with expected sensitivities is given. The basic principles and the different possible productions are summarized. A discussion of the physical background is included. Methods for quantitative analysis are discussed. Experimental arrangements are indicated and factors affecting the accuracy of analysis are considered. A number of applications are briefly described and a comparison with X-ray emission (PIXE) is made

  11. Dimensional comparison theory.

    Science.gov (United States)

    Möller, Jens; Marsh, Herb W

    2013-07-01

    Although social comparison (Festinger, 1954) and temporal comparison (Albert, 1977) theories are well established, dimensional comparison is a largely neglected yet influential process in self-evaluation. Dimensional comparison entails a single individual comparing his or her ability in a (target) domain with his or her ability in a standard domain (e.g., "How good am I in math compared with English?"). This article reviews empirical findings from introspective, path-analytic, and experimental studies on dimensional comparisons, categorized into 3 groups according to whether they address the "why," "with what," or "with what effect" question. As the corresponding research shows, dimensional comparisons are made in everyday life situations. They impact on domain-specific self-evaluations of abilities in both domains: Dimensional comparisons reduce self-concept in the worse off domain and increase self-concept in the better off domain. The motivational basis for dimensional comparisons, their integration with recent social cognitive approaches, and the interdependence of dimensional, temporal, and social comparisons are discussed. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  12. Self-adaptive numerical integrator for analytic functions

    International Nuclear Information System (INIS)

    Garribba, S.; Quartapelle, L.; Reina, G.

    1978-01-01

    A new adaptive algorithm for the integration of analytical functions is presented. The algorithm processes the integration interval by generating local subintervals whose length is controlled through a feedback loop. The control is obtained by means of a relation derived on an analytical basis and valid for an arbitrary integration rule: two different estimates of an integral are used to compute the interval length necessary to obtain an integral estimate with accuracy within the assigned error bounds. The implied method for local generation of subintervals and an effective assumption of error partition among subintervals give rise to an adaptive algorithm provided with a highly accurate and very efficient integration procedure. The particular algorithm obtained by choosing the 6-point Gauss-Legendre integration rule is considered and extensive comparisons are made with other outstanding integration algorithms

  13. Characterization of isolated polyamide thin films of RO and NF membranes using novel TEM techniques

    KAUST Repository

    Pacheco, Federico A.

    2010-08-15

    Achieving a better understanding of transport and rejection mechanisms in RO and NF membranes requires more detailed information of the nanostructure of polyamide thin films. This study reports on two novel transmission electron microscopy (TEM) techniques for characterizing polyamide nanostructure. The first technique produces cross-sectional images of isolated polyamide thin films by removing the polysulfone support from regular TEM cross-sections. In the second technique called " projected area" TEM (PA-TEM), isolated polyamide thin films are placed with their surface perpendicular to the electron beam. The resulting images capture the thickness, morphology and mass density of the entire thin film. In combination, these new techniques provide information on polyamide nanostructure that is not evident using conventional methods. For the commercial RO membrane ESPA3, the cross-sectional view of the isolated polyamide thin film shows a 30-60. nm thick base of nodular polyamide (presumably the separation barrier) that forms a relatively smooth interface with the polysulfone support. Above this, a more open structure of loose polyamide extends outward giving rise to the ridge-and-valley surface structure. In PA-TEM images, the ridges and valleys correspond to the dark and bright regions, respectively; the polyamide nodular base appears as round features forming an irregular honeycomb pattern throughout the images. Membrane cross-sections were prepared with a simple resin embedding protocol using the acrylic resin LR White. The protocol did not require dehydration steps, and was applicable to both dry and wet membrane samples. Artifacts that may be produced during sample preparation were also documented. © 2010 Elsevier B.V.

  14. Characterization of isolated polyamide thin films of RO and NF membranes using novel TEM techniques

    KAUST Repository

    Pacheco, Federico A.; Pinnau, Ingo; Reinhard, Martin; Leckie, James O.

    2010-01-01

    Achieving a better understanding of transport and rejection mechanisms in RO and NF membranes requires more detailed information of the nanostructure of polyamide thin films. This study reports on two novel transmission electron microscopy (TEM) techniques for characterizing polyamide nanostructure. The first technique produces cross-sectional images of isolated polyamide thin films by removing the polysulfone support from regular TEM cross-sections. In the second technique called " projected area" TEM (PA-TEM), isolated polyamide thin films are placed with their surface perpendicular to the electron beam. The resulting images capture the thickness, morphology and mass density of the entire thin film. In combination, these new techniques provide information on polyamide nanostructure that is not evident using conventional methods. For the commercial RO membrane ESPA3, the cross-sectional view of the isolated polyamide thin film shows a 30-60. nm thick base of nodular polyamide (presumably the separation barrier) that forms a relatively smooth interface with the polysulfone support. Above this, a more open structure of loose polyamide extends outward giving rise to the ridge-and-valley surface structure. In PA-TEM images, the ridges and valleys correspond to the dark and bright regions, respectively; the polyamide nodular base appears as round features forming an irregular honeycomb pattern throughout the images. Membrane cross-sections were prepared with a simple resin embedding protocol using the acrylic resin LR White. The protocol did not require dehydration steps, and was applicable to both dry and wet membrane samples. Artifacts that may be produced during sample preparation were also documented. © 2010 Elsevier B.V.

  15. Gas Atomization of Aluminium Melts: Comparison of Analytical Models

    Directory of Open Access Journals (Sweden)

    Georgios Antipas

    2012-06-01

    Full Text Available A number of analytical models predicting the size distribution of particles during atomization of Al-based alloys by N2, He and Ar gases were compared. Simulations of liquid break up in a close coupled atomizer revealed that the finer particles are located near the center of the spray cone. Increasing gas injection pressures led to an overall reduction of particle diameters and caused a migration of the larger powder particles towards the outer boundary of the flow. At sufficiently high gas pressures the spray became monodisperse. The models also indicated that there is a minimum achievable mean diameter for any melt/gas system.

  16. Parametric validations of analytical lifetime estimates for radiation belt electron diffusion by whistler waves

    Directory of Open Access Journals (Sweden)

    A. V. Artemyev

    2013-04-01

    Full Text Available The lifetimes of electrons trapped in Earth's radiation belts can be calculated from quasi-linear pitch-angle diffusion by whistler-mode waves, provided that their frequency spectrum is broad enough and/or their average amplitude is not too large. Extensive comparisons between improved analytical lifetime estimates and full numerical calculations have been performed in a broad parameter range representative of a large part of the magnetosphere from L ~ 2 to 6. The effects of observed very oblique whistler waves are taken into account in both numerical and analytical calculations. Analytical lifetimes (and pitch-angle diffusion coefficients are found to be in good agreement with full numerical calculations based on CRRES and Cluster hiss and lightning-generated wave measurements inside the plasmasphere and Cluster lower-band chorus waves measurements in the outer belt for electron energies ranging from 100 keV to 5 MeV. Comparisons with lifetimes recently obtained from electron flux measurements on SAMPEX, SCATHA, SAC-C and DEMETER also show reasonable agreement.

  17. Comparative analytics of infusion pump data across multiple hospital systems.

    Science.gov (United States)

    Catlin, Ann Christine; Malloy, William X; Arthur, Karen J; Gaston, Cindy; Young, James; Fernando, Sudheera; Fernando, Ruchith

    2015-02-15

    A Web-based analytics system for conducting inhouse evaluations and cross-facility comparisons of alert data generated by smart infusion pumps is described. The Infusion Pump Informatics (IPI) project, a collaborative effort led by research scientists at Purdue University, was launched in 2009 to provide advanced analytics and tools for workflow analyses to assist hospitals in determining the significance of smart-pump alerts and reducing nuisance alerts. The IPI system allows facility-specific analyses of alert patterns and trends, as well as cross-facility comparisons of alert data uploaded by more than 55 participating institutions using different types of smart pumps. Tools accessible through the IPI portal include (1) charts displaying aggregated or breakout data on the top drugs associated with alerts, numbers of alerts per device or care area, and override-to-alert ratios, (2) investigative reports that can be used to characterize and analyze pump-programming errors in a variety of ways (e.g., by drug, by infusion type, by time of day), and (3) "drill-down" workflow analytics enabling users to evaluate alert patterns—both internally and in relation to patterns at other hospitals—in a quick and efficient stepwise fashion. The formation of the IPI analytics system to support a community of hospitals has been successful in providing sophisticated tools for member facilities to review, investigate, and efficiently analyze smart-pump alert data, not only within a member facility but also across other member facilities, to further enhance smart pump drug library design. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  18. A Structural Study of Escherichia coli Cells Using an In Situ Liquid Chamber TEM Technology

    Directory of Open Access Journals (Sweden)

    Yibing Wang

    2015-01-01

    Full Text Available Studying cell microstructures and their behaviors under living conditions has been a challenging subject in microbiology. In this work, in situ liquid chamber TEM was used to study structures of Escherichia coli cells in aqueous solutions at a nanometer-scale resolution. Most of the cells remained intact under electron beam irradiation, and nanoscale structures were observed during the TEM imaging. The analysis revealed structures of pili surrounding the E. coli cells; the movements of the pili in the liquid were also observed during the in situ tests. This technology also allowed the observation of features of the nucleoid in the E. coli cells. Overall, in situ TEM can be applied as a valuable tool to study real-time microscopic structures and processes in microbial cells residing in native aqueous solutions.

  19. Analytical Model for High Impedance Fault Analysis in Transmission Lines

    Directory of Open Access Journals (Sweden)

    S. Maximov

    2014-01-01

    Full Text Available A high impedance fault (HIF normally occurs when an overhead power line physically breaks and falls to the ground. Such faults are difficult to detect because they often draw small currents which cannot be detected by conventional overcurrent protection. Furthermore, an electric arc accompanies HIFs, resulting in fire hazard, damage to electrical devices, and risk with human life. This paper presents an analytical model to analyze the interaction between the electric arc associated to HIFs and a transmission line. A joint analytical solution to the wave equation for a transmission line and a nonlinear equation for the arc model is presented. The analytical model is validated by means of comparisons between measured and calculated results. Several cases of study are presented which support the foundation and accuracy of the proposed model.

  20. An approximate analytical approach to resampling averages

    DEFF Research Database (Denmark)

    Malzahn, Dorthe; Opper, M.

    2004-01-01

    Using a novel reformulation, we develop a framework to compute approximate resampling data averages analytically. The method avoids multiple retraining of statistical models on the samples. Our approach uses a combination of the replica "trick" of statistical physics and the TAP approach for appr...... for approximate Bayesian inference. We demonstrate our approach on regression with Gaussian processes. A comparison with averages obtained by Monte-Carlo sampling shows that our method achieves good accuracy....

  1. In-situ TEM characterization of nanomaterials and devices

    KAUST Repository

    Kim, Moon; Park, Seongyong; Cha, Dong Kyu; Kim, Jiyoung; Floresca, Herman Carlo; Lu, Ning; Wang, Jinguo

    2011-01-01

    Electrical properties of nano size devices were directly measured by TEM. Real time observation of phase transition behavior in PRAM revealed that the volume of the crystalline phase is the main factor in determining cell resistance. In the transistor device, we have identified the doping type and area by measuring the I-V curve at the individual nano contact on the specimen. The evolution of the graphene edge structure was controlled and monitored at and up to 1200°C in-situ. © 2011 IEEE.

  2. In-situ TEM characterization of nanomaterials and devices

    KAUST Repository

    Kim, Moon

    2011-10-01

    Electrical properties of nano size devices were directly measured by TEM. Real time observation of phase transition behavior in PRAM revealed that the volume of the crystalline phase is the main factor in determining cell resistance. In the transistor device, we have identified the doping type and area by measuring the I-V curve at the individual nano contact on the specimen. The evolution of the graphene edge structure was controlled and monitored at and up to 1200°C in-situ. © 2011 IEEE.

  3. On the Analytical Solution of Non-Orthogonal Stagnation Point Flow towards a Stretching Sheet

    DEFF Research Database (Denmark)

    Kimiaeifar, Amin; Bagheri, G. H.; Barari, Amin

    2011-01-01

    An analytical solution for non-orthogonal stagnation point for the steady flow of a viscous and incompressible fluid is presented. The governing nonlinear partial differential equations for the flow field are reduced to ordinary differential equations by using similarity transformations existed...... in the literature and are solved analytically by means of the Homotopy Analysis Method (HAM). The comparison of results from this paper and those published in the literature confirms the precise accuracy of the HAM. The resulting analytical equation from HAM is valid for entire physical domain and effective...

  4. Comparison of EPRI safety valve test data with analytically determined hydraulic results

    International Nuclear Information System (INIS)

    Smith, L.C.; Howe, K.S.

    1983-01-01

    NUREG-0737 (November 1980) and all subsequent U.S. NRC generic follow-up letters require that all operating plant licensees and applicants verify the acceptability of plant specific pressurizer safety valve piping systems for valve operation transients by testing. To aid in this verification process, the Electric Power Research Institute (EPRI) conducted an extensive testing program at the Combustion Engineering Test Facility. Pertinent tests simulating dynamic opening of the safety valves for representative upstream environments were carried out. Different models and sizes of safety valves were tested at the simulated operating conditions. Transducers placed at key points in the system monitored a variety of thermal, hydraulic and structural parameters. From this data, a more complete description of the transient can be made. The EPRI test configuration was analytically modeled using a one-dimensional thermal hydraulic computer program that uses the method of characteristics approach to generate key fluid parameters as a function of space and time. The conservative equations are solved by applying both the implicit and explicit characteristic methods. Unbalanced or wave forces were determined for each straight run of pipe bounded on each side by a turn or elbow. Blowdown forces were included, where appropriate. Several parameters were varied to determine the effects on the pressure, hydraulic forces and timings of events. By comparing these quantities with the experimentally obtained data, an approximate picture of the flow dynamics is arrived at. Two cases in particular are presented. These are the hot and cold loop seal discharge tests made with the Crosby 6M6 spring-loaded safety valve. Included in the paper is a description of the hydraulic code, modeling techniques and assumptions, a comparison of the numerical results with experimental data and a qualitative description of the factors which govern pipe support loading. (orig.)

  5. Post Irradiation TEM Investigation of ZrN Coated U(Mo) Particles Prepared with FIB

    Energy Technology Data Exchange (ETDEWEB)

    Van Renterghem, W.; Leenaers, A.; Van den Berghe, S.; Miller, B. D.; Gan, J.; Madden, J. W.; Keiser, D. D.; Palancher, H.; Hofman, G. L.; Breitkreuz, H.

    2015-10-01

    In the framework of the Selenium project, two dispersion fuel plates were fabricated with Si and ZrN coated fuel particles and irradiated in the Br2 reactor of SCK•CEN to high burn-up. The first analysis of the irradiated plate proved the reduced swelling of the fuel plate and interaction layer growth up to 70% burn-up. The question was raised how the structure of the interaction layer had been affected by the irradiation and how the structure of the fuel particles had evolved. Hereto, samples from the ZrN coated UMo particles were prepared for transmission electron microscopy (TEM) using focused ion beam milling (FIB) at INL. The FIB technique allowed to precisely select the area of the interaction layer and/or fuel to produce a sample that is TEM transparent over an area of 20 by 20 µm. In this contribution, the first TEM results will be presented from the 66% burn-up sample.

  6. Development of a non-destructive micro-analytical method for stable carbon isotope analysis of transmission electron microscope (TEM) samples

    Energy Technology Data Exchange (ETDEWEB)

    Hode, Tomas [Department of Geology, Portland State University, Portland, P.O. Box 751, OR 97201 (United States)], E-mail: hode@pdx.edu; Kristiansson, Per; Elfman, Mikael [Division of Nuclear Physics, Department of Physics, Lund Institute of Technology, Lund University, P.O. Box 118, SE-221 00 Lund (Sweden); Hugo, Richard C.; Cady, Sherry L. [Department of Geology, Portland State University, Portland, P.O. Box 751, OR 97201 (United States)

    2009-10-01

    The biogenicity of ancient morphological microfossil-like objects can be established by linking morphological (e.g. cell remnants and extracellular polymeric matrix) and chemical (e.g. isotopes, biomarkers and biominerals) evidence indicative of microorganisms or microbial activity. We have developed a non-destructive micro-analytical ion beam system capable of measuring with high spatial resolution the stable carbon isotope ratios of thin samples used for transmission electron microscopy. The technique is based on elastic scattering of alpha particles with an energy of 2.751 MeV. At this energy the {sup 13}C cross section is enhanced relative to the pure Rutherford cross section for {sup 13}C, whereas the {sup 12}C cross section is reduced relative to its pure Rutherford cross section. Here we report the initial results of this experimental approach used to characterize ultramicrotomed sections of sulfur-embedded graphite and microbial cells.

  7. A multi-band semi-analytical algorithm for estimating chlorophyll-a concentration in the Yellow River Estuary, China.

    Science.gov (United States)

    Chen, Jun; Quan, Wenting; Cui, Tingwei

    2015-01-01

    In this study, two sample semi-analytical algorithms and one new unified multi-band semi-analytical algorithm (UMSA) for estimating chlorophyll-a (Chla) concentration were constructed by specifying optimal wavelengths. The three sample semi-analytical algorithms, including the three-band semi-analytical algorithm (TSA), four-band semi-analytical algorithm (FSA), and UMSA algorithm, were calibrated and validated by the dataset collected in the Yellow River Estuary between September 1 and 10, 2009. By comparing of the accuracy of assessment of TSA, FSA, and UMSA algorithms, it was found that the UMSA algorithm had a superior performance in comparison with the two other algorithms, TSA and FSA. Using the UMSA algorithm in retrieving Chla concentration in the Yellow River Estuary decreased by 25.54% NRMSE (normalized root mean square error) when compared with the FSA algorithm, and 29.66% NRMSE in comparison with the TSA algorithm. These are very significant improvements upon previous methods. Additionally, the study revealed that the TSA and FSA algorithms are merely more specific forms of the UMSA algorithm. Owing to the special form of the UMSA algorithm, if the same bands were used for both the TSA and UMSA algorithms or FSA and UMSA algorithms, the UMSA algorithm would theoretically produce superior results in comparison with the TSA and FSA algorithms. Thus, good results may also be produced if the UMSA algorithm were to be applied for predicting Chla concentration for datasets of Gitelson et al. (2008) and Le et al. (2009).

  8. Quantitative TEM study of the precipitation microstructure in aluminium alloy Al(MgSiCu) 6056 T6

    International Nuclear Information System (INIS)

    Delmas, F.; Casanove, M.J.; Lours, P.; Couret, A.; Coujou, A.

    2004-01-01

    The precipitate microstructure in the last-generation aluminium alloy 6056 T6 [AlMgSiCu] is investigated using three complementary techniques of transmission electron microscopy (TEM) with a special focus on the density and volume fraction of strengthening particles. High-resolution TEM allows the identification of the precipitates and the measurement of the precipitate sizes to be performed. Conventional TEM is used to evaluate the number of precipitates in the investigated area as well as their distribution in the matrix. In situ TEM straining, via the analysis of the dislocation slip traces, permits to determine precisely the thickness and the volume of the foil in the region where the precipitates are analysed. Taking into account the shape and the dimensions of precipitates with respect to the foil thickness, a novel methodology for measuring the volume density and the volume fraction of precipitates is proposed

  9. Study of InGaN/GaN quantum dot systems by TEM techniques and photoluminescence spectroscopy

    International Nuclear Information System (INIS)

    Kashtiban, R J; Bangert, U; Harvey, A J; Sherliker, B; Halsall, M P

    2010-01-01

    InGaN/GaN multilayer quantum dot structures produced by MOCVD techniques on c-plane sapphire were studied by transmission electron microscopy (TEM) and photoluminescence (PL) techniques. Indium fluctuations ranging from 1-4 nm were observed with both energy filtered TEM (EFTEM) and high angle annular dark field (HAADF) scanning TEM. The existence of V-shaped defects with nucleation centres at the termination of threading dislocation were observed in HAADF images. There was also evidence of the formation of large quantum dots at low densities from lattice HRTEM images. This was further confirmed by PL measurements through the observation of a single sharp line at low power with the typical saturation behaviour at higher power excitation.

  10. Multi-component and multi-array TEM detection in karst tunnels

    International Nuclear Information System (INIS)

    Sun, Huaifeng; Li, Shucai; Su, Maoxin; Xue, Yiguo; Li, Xiu; Qi, Zhipeng

    2012-01-01

    Emerging applications of transient electromagnetic methods (TEM) in tunnelling require higher resolution on the distributions and shapes of low resistivity bodies, such as karst water and karst pipes, using multi-component and multi-array receivers. However, there are no apparent resistivity definitions for both vertical and horizontal components with offsets inside the loop. Although the raw field can show the differences of the earth electric structure, it is not straightforward. Apparent resistivity is very convenient and easy for engineers. We have developed a method for multi-component and multi-array TEM which can be applied in tunnelling and defined the expressions of apparent resistivity. This method takes advantage of the difference in resolution among components. A homogeneous half-space model and four typical three-layered models are used to test the effectiveness of the new definition. A field case history is carried out and analysed to demonstrate the viability of this technique. The results suggest that it is feasible to use the technique in tunnelling, especially for identifying the spatial distribution of karst water and karst pipes. (paper)

  11. Pre-analytical and Analytical Variables Affecting the Measurement of Plasma-Derived Microparticle Tissue Factor Activity

    Science.gov (United States)

    Lee, RD; Barcel, DA; Williams, JC; Wang, JG; Boles, JC; Manly, DA; Key, NS; Mackman, N

    2011-01-01

    Introduction Elevated levels of tissue factor positive (TF+) microparticles (MPs) are observed in plasma from a variety of patients with an increased risk of thrombosis. We and others have described the measurement of TF activity in MPs isolated from plasma. The aim of this study was to investigate the effects of pre-analytical and analytical variables on TF activity of MPs isolated from blood of healthy volunteers treated ex vivo with or without bacterial lipopolysaccharide. Materials and Methods We evaluated the following parameters: use of different centrifugation speeds to isolate the MPs; comparison of TF activity of MPs isolated from platelet poor plasma versus platelet free plasma; effect of freeze/thaw on MP TF activity; and comparison of the MP TF activity assay with the measurement of TF protein by ELISA or flow cytometry. Results MPs prepared from platelet poor plasma by centrifugation at 20,000 × g or 100,000 × g for 15 minutes had similar levels of TF activity. However, significantly less TF activity was found in MPs isolated from platelet free plasma compared with platelet poor plasma. Interestingly, freeze/thawing of the plasma showed donor to donor variation in MP TF activity, with a moderate increase in some individuals. Conclusion TF+ MPs can be quantitatively isolated from platelet poor or platelet free plasma by centrifugation at 20,000 × g for 15 minutes. Measurement of MP TF activity in plasma can be used to detect a prothrombotic state in patients with various diseases. PMID:21737126

  12. Static shift correction of MT data in Tohoku district using TEM soundings; TEM ho data wo mochiita Tohoku chiho MT ho data no statistic shift hosei

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, N; Kumekawa, Y; Miura, Y; Takasugi, S [GERD Geothermal Energy Research and Development Co. Ltd., Tokyo (Japan); Fujinawa, Y [National Research Institute for Disaster Prevention, Tsukuba (Japan)

    1997-05-27

    There is a possibility that the wide-band MT observation data obtained in the central part of Tohoku district include the static shift effect. To grasp the static shift effect in the MT data, the TEM soundings were conducted at all the site where the MT data were measured. The TEM sounding system was developed for the shallow survey depth ranging from 5 m to 150 m. When showing the measured results on the histogram, it was found that the static shifts were concentrated in the vicinity of zero. About 70% of the data was below 0.2 decade. Only a slight static shift effect was observed. This means that the results obtained by the two-dimensional analysis are plausible. Especially, the static shift around plain was small. Therefore, the current results around the plain were trustful. On the other hand, the static shift in the mountainous area was rather large. Accordingly, the results around the mountainous area should be carefully treated. 7 refs., 10 figs.

  13. Study of a vibrating plate: comparison between experimental (ESPI) and analytical results

    Science.gov (United States)

    Romero, G.; Alvarez, L.; Alanís, E.; Nallim, L.; Grossi, R.

    2003-07-01

    Real-time electronic speckle pattern interferometry (ESPI) was used for tuning and visualization of natural frequencies of a trapezoidal plate. The plate was excited to resonant vibration by a sinusoidal acoustical source, which provided a continuous range of audio frequencies. Fringe patterns produced during the time-average recording of the vibrating plate—corresponding to several resonant frequencies—were registered. From these interferograms, calculations of vibrational amplitudes by means of zero-order Bessel functions were performed in some particular cases. The system was also studied analytically. The analytical approach developed is based on the Rayleigh-Ritz method and on the use of non-orthogonal right triangular co-ordinates. The deflection of the plate is approximated by a set of beam characteristic orthogonal polynomials generated by using the Gram-Schmidt procedure. A high degree of correlation between computational analysis and experimental results was observed.

  14. Operator Training and TEMS Support: A Survey of Unit Leaders in Northern and Central California.

    Science.gov (United States)

    Young, Jason B; Galante, Joseph M; Sena, Matthew J

    2013-01-01

    Members of Special Weapons and Tactics (SWAT) teams routinely work in high-risk tactical situations. Awareness of the benefit of Tactical Emergency Medical Support (TEMS) is increasing but not uniformly emphasized. To characterize the current regional state of tactical medicine and identify potential barriers to more widespread implementation. A multiple-choice survey was administered to SWAT team leaders of 22 regional agencies in northern and central California. Questions focused on individual officer self-aid and buddy care training, the use and content of individual first aid kits (IFAKs), and the operational inclusion of a dedicated TEMS provider. Respondents included city police (54%), local county sheriff (36%), state law enforcement (5%), and federal law enforcement (5%). RESULTS showed that 100% of respondents thought it was ?Very Important? for SWAT officers to understand the basics of self-aid and buddy care and to carry an IFAK, while only 71% of respondents indicated that team members actually carried an IFAK. In addition, 67% indicated that tourniquets were part of the IFAK, and 91% of surveyed team leaders thought it was ?Very Important? for teams to have a trained medic available onsite at callouts or high-risk warrant searches. Also, 59% of teams used an organic TEMS element. The majority of SWAT team leaders recognize the benefit of basic Operator medical training and the importance of a TEMS program. Despite near 100% endorsement by unit-level leadership, a significant proportion of teams are lacking one of the key components including Operator IFAKs and/or tourniquets. Tactical team leaders, administrators, and providers should continue to promote adequate Operator training and equipment as well as formal TEMS support. 2013.

  15. TEM-187, a new extended-spectrum β-lactamase with weak activity in a Proteus mirabilis clinical strain.

    Science.gov (United States)

    Corvec, Stéphane; Beyrouthy, Racha; Crémet, Lise; Aubin, Guillaume Ghislain; Robin, Frédéric; Bonnet, Richard; Reynaud, Alain

    2013-05-01

    A Proteus mirabilis clinical strain (7001324) was isolated from urine sample of a patient hospitalized in a long-term-care facility. PCR and cloning experiments performed with this strain identified a novel TEM-type β-lactamase (TEM-187) differing by four amino acid substitutions (Leu21Phe, Arg164His, Ala184Val, and Thr265Met) from TEM-1. This characterization provides further evidence for the diversity of extended-spectrum β-lactamases (ESBL) produced by P. mirabilis and for their potential spread to other Enterobacteriaceae due to a lack of sensitive detection methods used in daily practice.

  16. Microfabricated Nanofluidic cells for in situ liquid TEM

    DEFF Research Database (Denmark)

    Laganà, Simone

    Over the last decade, transmission electron microscopy (TEM) has been revolutionized not only by the introduction of new and very sophisticated hardware for improved resolution, such as aberration correctors and monochromators, but also by the improvement of new methods that have provided more than......, allowing quantitative and high-precision acquisition of liquid thickness maps, high resolution observations and meaningful information about synthesis of NPs from metal precursor solutions in confined space. Finally, a new concept device based on a Si3N4 membrane for plunge freezing fixation, which enables...

  17. Studying the interface between cyanobacteria and biotite mineral surfaces using FIB and TEM

    International Nuclear Information System (INIS)

    Ward, M B; Brown, A P

    2014-01-01

    Recent analysis of the bioweathering of minerals has highlighted the challenges for investigating the interface between fungi or bacteria and the surface of the mineral that they live on. Transmission electron microscopy (TEM) with its ability to gather imaging information and collect elemental data at high spatial resolution is the ideal technique to analyse such interfaces. Further to this, a dual beam scanning electron and focused ion beam (FIB) microscope is an ideal instrument to prepare specimens for TEM because of its ability to simultaneously cut through hard and soft materials from specific sites of interest. There are however precautions that must be taken when analysing such mineral systems. The electron beam sensitive nature of most sheet silicate minerals means that consideration has to be made as to whether the structure and/or chemistry of the material is being altered during (S)TEM analysis. Here, results from a study of cyanobacteria grown on the surface of biotite are discussed. Particular reference is given to the methods used to determine an electron beam intensity threshold, below which STEM-EDX analysis could be performed without detrimental alteration to the mineral

  18. TEMs but not DKK1 could serve as complementary biomarkers for AFP in diagnosing AFP-negative hepatocellular carcinoma.

    Directory of Open Access Journals (Sweden)

    Liping Mao

    Full Text Available Hepatitis B virus (HBV-related hepatocellular carcinoma (HCC is prevalent worldwide. Despite its limitations, serum alpha-fetoprotein (AFP remains the most widely-used biomarker for the diagnosis of HCC. This study aimed to assess whether measurement of peripheral plasma Dickkopf-1 (DKK1 and Tie2-expressing monocytes (TEMs could overcome the limitations of AFP and improve the diagnostic accuracy of HCC.Plasma DKK1 level and the percentage of TEMs in peripheral CD14+CD16+ monocytes from HCC patients (n = 82, HBV-related liver cirrhosis (LC patients (n = 29, chronic hepatitis B (CHB infected patients (n = 28 and healthy volunteers (n = 31 were analyzed by ELISA and flow cytometry. Receiver operating characteristic (ROC curves were used to analyze a single biomarker, or a combination of two or three biomarkers. Univariate and multivariate analyses were performed to assess the significance of each marker in prediction of HCC and AFP-negative HCC from LC patients.The percentage of TEMs in peripheral CD14+CD16+ monocytes and plasma level of DKK1 in HCC group were significantly higher than those in LC, CHB and healthy control groups (all P-values 0.05. A combination of DKK1, TEMs and AFP measurements increased the AUC for HCC diagnosis as compared with either marker alone (0.833; 95%CI 0.768-0.886. The AUC for TEMs was 0.692 (95% CI 0.564-0.819 in differentiating AFP-negative HCC from LC, with a sensitivity of 80.0% and a specificity of 65.52%. Only TEMs prevailed as a significant predictor for AFP-negative HCC differentiating from LC patients in univariate and multivariate analyses (P = 0.016, P = 0.023.TEMs and DKK1 may prove to be potential complementary biomarkers for AFP in the diagnosis of HCC. TEMs rather than DKK1 could serve as a complementary biomarker for AFP in the differential diagnosis of AFP-negative HCC versus LC patients.

  19. Preparation of hard-to-make TEM samples using the FIB microscope; Praeparation von kompliziert herstellbaren TEM-Proben mit dem FIB-Mikroskop

    Energy Technology Data Exchange (ETDEWEB)

    Volkert, C.A. [Forschungszentrum Karlsruhe, Karlsruhe (Germany); Heiland, B.; Kauffmann, F. [Max-Planck-Inst. fuer Metallforschung, Stuttgart (Germany)

    2003-04-01

    The focused ion beam (FIB) microscope has become an important tool for the preparation of TEM samples over the last few years. Preparation of samples with the FIB has some specific advantages over conventional preparation methods which make it possible to prepare samples that would otherwise be difficult to prepare. The advantages that will be illustrated in this paper include: (1) precise selection of the sample volume to be prepared, (2) preparation of brittle materials, (3) preparation of highly stressed materials, and (4) preparation of composites composed of materials with widely differing properties. These advantages will be illustrated through several examples including cross-sectional preparation of nanocrystalline Ti-Si-N films, thermal barrier coatings, fatigued Al films, pecan shells, apatite, and metal whiskers. [German] Das Focused Ion Beam (FIB)-Mikroskop ist in den letzten Jahren zu einem wichtigen Werkzeug fuer die Praeparation von TEM-Proben geworden. Die Probenpraeparation mittels FIB hat gegenueber den konventionellen Praeparationsmethoden eine Reihe spezifischer Vorteile, die es ermoeglichen, Proben herzustellen, die ansonsten schwierig zu praeparieren waeren. Die in diesem Beitrag veranschaulichten Vorteile sind: (1) praezise Auswahl des zu praeparierenden Probenvolumens, (2) Praeparation von sproeden Materialien, (3) Praeparation von Materialien mit hohen Eigenspannungen, und (4) die Praeparation von Verbundwerkstoffen, die aus Komponenten mit stark unterschiedlichen Eigenschaften bestehen. Diese Vorteile werden anhand verschiedener Beispiele wie der Querschnittspraeparation von nanokristallinen Ti-Si-N-Schichten, thermischen Barriereschichten, Al-Schichten nach Ermuedung, Pekan-Nussschalen, Apatiten und Metallwhiskern veranschaulicht.

  20. TEM investigations of microstructures of combustion aerosols

    International Nuclear Information System (INIS)

    Marquardt, A.; Hackfort, H.; Borchardt, J.; Schober, T.; Friedrich, J.

    1992-12-01

    In the incineration of organic material, apart from a series of gaseous pollutants, particulate pollutants or combustion aerosols also arise. The latter frequently consist of particles with a solid core of carbon to which a large number of inorganic and organic compounds are attached. These primarily include the polycyclic aromatic hydrocarbons (PAH) and their nitro-derivatives (NPAH), whose mutagenic or carcinogenic effect is known. The invisible particle sizes in the nanometer range, whose retention in the incineration off-gas is not state of the art, are of increasing significance for man and environment. On the one hand, they are deposited almost completely in the human lung. On the other hand, due to their fine dispersity they have along residence time in the atmosphere where they participate in chemical reactions and climatically significant processes. Important insights about the formation process of combustion aerosols are to be expected from the imaging of their microstructures in the transmission electron microscope (TEM). The present contribution describes the development and application of a representative sampling procedure for aerosols from a partial flow of flue gas from a fluidized-bed furnace. The method developed consists of electrically charging aerosol particles in situ and subsequently selectively precipitating them onto a microscope slide in an electric field. TEM studies of aerosol microstructures on the microscope slides revealed that in the combustion of petrol and heating oil under different combustion conditions in principle the same particle structures result, whereas in the incineration of used lubricating oil quite different particle structures were found. Results from the literature on aerosol microstructures in exhaust gases from petrol and diesel engines demonstrate agreement with the results of this study in the basic structure of the particles. (orig.) [de

  1. Comparison of ANL containment codes with SNR-300 simulation experiments

    International Nuclear Information System (INIS)

    Marchertas, A.H.; Wang, C.Y.; Fistedis, S.H.

    1976-01-01

    A comparison of REXCO and ICECO code predictions is made with data obtained from experiments of LMFBR excursion models. The comparisons are based on published results of tests conducted for the safety analysis of the SNR-300 fast breeder. The test configurations consist of a centrally located spherical source immersed in a pool of water which is encased in a cylindrical container. The cylinical walls of the container are prestressed by holddown bolts which span the two rigid ends. The space above the surface of the water within the container is occupied by air. Although certain aspects of the tests could not be simulated by the analytical models exactly, the comparison of results shows quite close agreement. The fact that the REXCO and ICECO codes involve different analytical formulations, their own close correspondence of results lends added credence to the value of analytical predictions

  2. Cassette-based in-situ TEM sample inspection in the dual-beam FIB

    International Nuclear Information System (INIS)

    Kendrick, A B; Moore, T M; Zaykova-Feldman, L; Amador, G; Hammer, M

    2008-01-01

    A novel method is presented, combining site-specific TEM sample preparation and in-situ STEM analysis in a dual-beam microscope (FIB/SEM) fitted with a chamber mounted nano-manipulator. TEM samples are prepared using a modified in-situ, lift-out method, whereby the samples are thinned and oriented for immediate in-situ STEM analysis using the tilt, translation, and rotation capabilities of a FIB/SEM sample stage, a nano-manipulator, and a novel cassette. This cassette can provide a second tilt axis, orthogonal to the stage tilt axis, so that the STEM image contrast can be optimized to reveal the structural features of the sample (true STEM imaging in the FIB/SEM). The angles necessary for stage rotation and probe shaft rotation are calculated based on the position of the nano-manipulator relative to the stage and door and the stage tilt angle. A FIB/SEM instrument, equipped with a high resolution scanning electron column, can provide sufficiently high image resolution to enable many failure analysis and process control applications to be successfully carried out without requiring the use of a separate dedicated TEM/STEM instrument. The benefits of this novel approach are increased throughput and reduced cost per sample. Comparative analysis of different sample preparation methods is provided, and the STEM images obtained are shown.

  3. Polymersomes, smaller than you think: ferrocene as a TEM probe to determine core structure

    International Nuclear Information System (INIS)

    Johnston, A. H.; Dalton, P. D.; Newman, T. A.

    2010-01-01

    By incorporating ferrocene into the hydrophobic membrane of PEG-b-PCL polymersome nanoparticles it is possible to selectively visualize their core using Transmission Electron Microscopy (TEM). Two different sizes of ferrocene-loaded polymersomes with mean hydrodynamic diameters of approximately 40 and 90 nm were prepared. Image analysis of TEM pictures of these polymersomes found that the mean diameter of the core was 4-5 times smaller than the mean hydrodynamic diameter. The values obtained also allow the surface diameter and internal volume of the core to be calculated.

  4. Application of analytic hierarchy process to extract the user's purpose of expert systems

    International Nuclear Information System (INIS)

    Gofuku, Akio; Wakabayashi, Jiro; Morimoto, Takashi.

    1992-01-01

    This paper deals with an application of analytic hierarchy process (AHP) to extract the user's purpose which must be input to expert systems. In the AHP, the process to obtain the weights for criteria by pairwise comparisons is interpreted as the extraction of the decision marker's idea about the importance of each criterion. With this interpretation, the analytic hierarchy process is applied to extract the analyst's idea of the weights of several factors to select constitutive equations suitable for a target analysis in a model selection support expert system under development for numerical simulation of nuclear thermal-hydraulics; the constitutive equations are ordinary introduced in a liquid-vapor two-phase flow analysis. Furthermore, an algorithm by applying the graph theory is shown to evaluate covering condition to obtain the weights from incomplete pairwise comparisons. (author)

  5. Matching of analytical and numerical solutions for neutron stars of arbitrary rotation

    International Nuclear Information System (INIS)

    Pappas, George

    2009-01-01

    We demonstrate the results of an attempt to match the two-soliton analytical solution with the numerically produced solutions of the Einstein field equations, that describe the spacetime exterior of rotating neutron stars, for arbitrary rotation. The matching procedure is performed by equating the first four multipole moments of the analytical solution to the multipole moments of the numerical one. We then argue that in order to check the effectiveness of the matching of the analytical with the numerical solution we should compare the metric components, the radius of the innermost stable circular orbit (R ISCO ), the rotation frequency and the epicyclic frequencies Ω ρ , Ω z . Finally we present some results of the comparison.

  6. Matching of analytical and numerical solutions for neutron stars of arbitrary rotation

    Energy Technology Data Exchange (ETDEWEB)

    Pappas, George, E-mail: gpappas@phys.uoa.g [Section of Astrophysics, Astronomy, and Mechanics, Department of Physics, University of Athens, Panepistimiopolis Zografos GR15783, Athens (Greece)

    2009-10-01

    We demonstrate the results of an attempt to match the two-soliton analytical solution with the numerically produced solutions of the Einstein field equations, that describe the spacetime exterior of rotating neutron stars, for arbitrary rotation. The matching procedure is performed by equating the first four multipole moments of the analytical solution to the multipole moments of the numerical one. We then argue that in order to check the effectiveness of the matching of the analytical with the numerical solution we should compare the metric components, the radius of the innermost stable circular orbit (R{sub ISCO}), the rotation frequency and the epicyclic frequencies {Omega}{sub {rho}}, {Omega}{sub z}. Finally we present some results of the comparison.

  7. Toxicologic evaluation of analytes from Tank 241-C-103

    International Nuclear Information System (INIS)

    Mahlum, D.D.; Young, J.Y.; Weller, R.E.

    1994-11-01

    Westinghouse Hanford Company requested PNL to assemble a toxicology review panel (TRP) to evaluate analytical data compiled by WHC, and provide advice concerning potential health effects associated with exposure to tank-vapor constituents. The team's objectives would be to (1) review procedures used for sampling vapors from tanks, (2) identify constituents in tank-vapor samples that could be related to symptoms reported by workers, (3) evaluate the toxicological implications of those constituents by comparison to establish toxicological databases, (4) provide advice for additional analytical efforts, and (5) support other activities as requested by WHC. The TRP represents a wide range of expertise, including toxicology, industrial hygiene, and occupational medicine. The TRP prepared a list of target analytes that chemists at the Oregon Graduate Institute/Sandia (OGI), Oak Ridge National Laboratory (ORNL), and PNL used to establish validated methods for quantitative analysis of head-space vapors from Tank 241-C-103. this list was used by the analytical laboratories to develop appropriate analytical methods for samples from Tank 241-C-103. Target compounds on the list included acetone, acetonitrile, ammonia, benzene, 1, 3-butadiene, butanal, n-butanol, hexane, 2-hexanone, methylene chloride, nitric oxide, nitrogen dioxide, nitrous oxide, dodecane, tridecane, propane nitrile, sulfur oxide, tributyl phosphate, and vinylidene chloride. The TRP considered constituent concentrations, current exposure limits, reliability of data relative to toxicity, consistency of the analytical data, and whether the material was carcinogenic or teratogenic. A final consideration in the analyte selection process was to include representative chemicals for each class of compounds found

  8. Mechanisms for ITB formation and control in Alcator C-Mod identified through gyrokinetic simulations of TEM turbulence

    International Nuclear Information System (INIS)

    Ernst, D.R.; Basse, N.; Bonoli, P.T.; Catto, P.J.; Fiore, C.L.; Greenwald, M.; Hubbard, A.E.; Marmar, E.S.; Porkolab, M.; Rice, J.E.; Zeller, K.; Zhurovich, K.; Dorland, W.

    2005-01-01

    Internal particle and thermal energy transport barriers are produced in Alcator C-Mod with off-axis ICRF heating, with core densities exceeding 10 21 m -3 , without core fueling, and with little change in the temperature profile. Applying on-axis ICRF heating controls the core density gradient and rate of rise. The present study employs linear and nonlinear gyrokinetic simulations of trapped electron mode (TEM) turbulence to explore mechanisms for ITB formation and control in Alcator C-Mod ITB experiments. Anomalous pinches are found to be negligible in our simulations; further, the collisional Ware pinch is sufficient to account for the slow density rise, lasting many energy confinement times. The simulations have revealed new nonlinear physics of TEM turbulence. The critical density gradient for onset of TEM turbulent transport is nonlinearly up-shifted by zonal flows. As the density profile peaks, during ITB formation, this nonlinear critical gradient is eventually exceeded, and the turbulent particle diffusivity from GS2 gyrokinetic simulations matches the particle diffusivity from transport analysis, within experimental errors. A stable equilibrium is then established when the TEM turbulent diffusion balances the Ware pinch in the ITB. This equilibrium is sensitive to temperature through gyroBohm scaling of the TEM turbulent transport, and the collisionality dependence of the neoclassical pinch, providing for control of the density rate of rise with on-axis RF heating. With no core particle fueling, and ∼1 mm between density spatial channels, the C-Mod experiments provide a nearly ideal test bed for particle transport studies. The pure TEM is the only unstable drift mode in the ITB, producing particle transport driven by the density gradient. (author)

  9. An analytical model for annular flow boiling heat transfer in microchannel heat sinks

    International Nuclear Information System (INIS)

    Megahed, A.; Hassan, I.

    2009-01-01

    An analytical model has been developed to predict flow boiling heat transfer coefficient in microchannel heat sinks. The new analytical model is proposed to predict the two-phase heat transfer coefficient during annular flow regime based on the separated model. Opposing to the majority of annular flow heat transfer models, the model is based on fundamental conservation principles. The model considers the characteristics of microchannel heat sink during annular flow and eliminates using any empirical closure relations. Comparison with limited experimental data was found to validate the usefulness of this analytical model. The model predicts the experimental data with a mean absolute error 8%. (author)

  10. Simple analytical expression for crosstalk estimation in homogeneous trench-assisted multi-core fibers

    DEFF Research Database (Denmark)

    Ye, Feihong; Tu, Jiajing; Saitoh, Kunimasa

    2014-01-01

    An analytical expression for the mode coupling coe cient in homogeneous trench-assisted multi-core fibers is derived, which has a sim- ple relationship with the one in normal step-index structures. The amount of inter-core crosstalk reduction (in dB) with trench-assisted structures compared...... to the one with normal step-index structures can then be written by a simple expression. Comparison with numerical simulations confirms that the obtained analytical expression has very good accuracy for crosstalk estimation. The crosstalk properties in trench-assisted multi-core fibers, such as crosstalk...... dependence on core pitch and wavelength-dependent crosstalk, can be obtained by this simple analytical expression....

  11. TEM Nano-Moiré Pattern Analysis of a Copper/Single Walled Carbon Nanotube Nanocomposite Synthesized by Laser Surface Implanting

    Directory of Open Access Journals (Sweden)

    Jay F. Tu

    2018-03-01

    Full Text Available In our previous studies, we have developed a wet process to synthesize a copper-single walled carbon nanotube (Cu–SWCNT metal nanocomposite with excellent mechanical properties. The nanostructure of this Cu–SWCNT composite was confirmed independently by energy-dispersive X-ray spectroscopy mapping, spectroscopy measurements, and Transmission Electron Microscope (TEM images with discernable SWCNT clusters in nano sizes. However, TEM images with discernable nano-sized SWCNT clusters are rare. In this paper, we present analysis of indirect TEM image patterns, such as moiré fringes, to infer the existence of SWCNT clusters within the copper matrix. Moiré fringes or patterns in the TEM images of a Cu–SWCNT nanocomposite could be generated due to the overlapping of more than one thin crystals with similar periodic arrangements of atoms, promoted by SWCNT clusters. However, the presence of moiré patterns is not a sufficient or a necessary condition for the existence of SWCNT clusters. It was found that based on the overlapping angle of two periodic arrangements, it is feasible to distinguish the moiré fringes induced by SWCNT clusters from those by other factors, such as dislocations. The ability to identify SWCNTs within the copper matrix based on indirect TEM moiré patterns helps to widen the usability of TEM images.

  12. Advantages of low beam energies in a TEM for valence EELS

    Science.gov (United States)

    Stöger-Pollach, M.; Pongratz, P.

    2010-02-01

    Since the availability of monochromators in transmission electron microscopes (TEMs), electron energy loss spectrometry (EELS) is widely used to determine band gaps and the dielectric properties of semiconductors on a nano-metre scale. Nevertheless, three physical effects hamper straightforward analysis: (a) relativistic energy losses, (b) the delocalization of the energy loss which is in the 10 nano-metreer range for valence losses, and (c) the presence of interface plasmons. When reducing the operation voltage of the TEM one can kill two birds with one stone: (a) the relativistic losses will disappear as soon as veinvestigated sample) and (b) the delocalization will decrease, because it also depends on the energy of the incident electron probe. The determination of the optical properties of quantum structures is discussed in the case of GaP/GaAs interface at 200 keV and 20 keV beam energy, respectively. Further, the influence of the delocalization of the energy loss signal is discussed theoretically and experimentally.

  13. Analytical dynamic modeling of fast trilayer polypyrrole bending actuators

    International Nuclear Information System (INIS)

    Amiri Moghadam, Amir Ali; Moavenian, Majid; Tahani, Masoud; Torabi, Keivan

    2011-01-01

    Analytical modeling of conjugated polymer actuators with complicated electro-chemo-mechanical dynamics is an interesting area for research, due to the wide range of applications including biomimetic robots and biomedical devices. Although there have been extensive reports on modeling the electrochemical dynamics of polypyrrole (PPy) bending actuators, mechanical dynamics modeling of the actuators remains unexplored. PPy actuators can operate with low voltage while producing large displacement in comparison to robotic joints, they do not have friction or backlash, but they suffer from some disadvantages such as creep and hysteresis. In this paper, a complete analytical dynamic model for fast trilayer polypyrrole bending actuators has been proposed and named the analytical multi-domain dynamic actuator (AMDDA) model. First an electrical admittance model of the actuator will be obtained based on a distributed RC line; subsequently a proper mechanical dynamic model will be derived, based on Hamilton's principle. The purposed modeling approach will be validated based on recently published experimental results

  14. Analytical inversions in remote sensing of particle size distributions. IV - Comparison of Fymat and Box-McKellar solutions in the anomalous diffraction approximation

    Science.gov (United States)

    Fymat, A. L.; Smith, C. B.

    1979-01-01

    It is shown that the inverse analytical solutions, provided separately by Fymat and Box-McKellar, for reconstructing particle size distributions from remote spectral transmission measurements under the anomalous diffraction approximation can be derived using a cosine and a sine transform, respectively. Sufficient conditions of validity of the two formulas are established. Their comparison shows that the former solution is preferable to the latter in that it requires less a priori information (knowledge of the particle number density is not needed) and has wider applicability. For gamma-type distributions, and either a real or a complex refractive index, explicit expressions are provided for retrieving the distribution parameters; such expressions are, interestingly, proportional to the geometric area of the polydispersion.

  15. Transmission Electron Microscopy (TEM) Sample Preparation of Si(1-x)Gex in c-Plane Sapphire Substrate

    Science.gov (United States)

    Kim, Hyun Jung; Choi, Sang H.; Bae, Hyung-Bin; Lee, Tae Woo

    2012-01-01

    The National Aeronautics and Space Administration-invented X-ray diffraction (XRD) methods, including the total defect density measurement method and the spatial wafer mapping method, have confirmed super hetero epitaxy growth for rhombohedral single crystalline silicon germanium (Si1-xGex) on a c-plane sapphire substrate. However, the XRD method cannot observe the surface morphology or roughness because of the method s limited resolution. Therefore the authors used transmission electron microscopy (TEM) with samples prepared in two ways, the focused ion beam (FIB) method and the tripod method to study the structure between Si1-xGex and sapphire substrate and Si1?xGex itself. The sample preparation for TEM should be as fast as possible so that the sample should contain few or no artifacts induced by the preparation. The standard sample preparation method of mechanical polishing often requires a relatively long ion milling time (several hours), which increases the probability of inducing defects into the sample. The TEM sampling of the Si1-xGex on sapphire is also difficult because of the sapphire s high hardness and mechanical instability. The FIB method and the tripod method eliminate both problems when performing a cross-section TEM sampling of Si1-xGex on c-plane sapphire, which shows the surface morphology, the interface between film and substrate, and the crystal structure of the film. This paper explains the FIB sampling method and the tripod sampling method, and why sampling Si1-xGex, on a sapphire substrate with TEM, is necessary.

  16. ANALISIS KUAT SINYAL DAN KUALITAS PANGGILAN JARINGAN GSM INDOOR DENGAN TEMS INVESTIGATION DAN G-NETTRACK PRO

    OpenAIRE

    Ida Bagus Ari Budiarta; Pande Ketut Sudiarta; IGAK. Diafari Djuni H.

    2016-01-01

    Kebutuhan akan teknologi GSM merupakan tantangan bagi provider untuk memberikan pelayanan terbaik bagi pengguna layanannya. Dalam proses layanan tersebut kemungkinan besar terdapat masalah yang terjadi. Pihak provider biasanya melakukan walk test untuk mengecek kekuatan sinyal yang dipancarkan oleh antena pemancar di dalam ruangan. Kebanyakan pihak provider menggunakan TEMS Investigation dalam melakukan walk test. Biaya walk test dengan TEMS Investigation bisa dikatakan cukup mahal. Namun den...

  17. The analytic hierarchy process as a support for decision making

    Directory of Open Access Journals (Sweden)

    Filipović Milanka

    2007-01-01

    Full Text Available The first part of this text deals with a convention site selection as one of the most lucrative areas in the tourism industry. The second part gives a further description of a method for decision making - the analytic hierarchy process. The basic characteristics: hierarchy constructions and pair wise comparison on the given level of the hierarchy are allured. The third part offers an example of application. This example is solved using the Super - Decision software, which is developed as a computer support for the analytic hierarchy process. This indicates that the AHP approach is a useful tool to help support a decision of convention site selection. .

  18. Data from the analytical performance of the Abaxis Piccolo Xpress point of care analyzer in whole blood, serum, and plasma

    Directory of Open Access Journals (Sweden)

    Kazunori Murata

    2018-02-01

    Full Text Available The objective of this study was to examine the analytical performance of 14 comprehensive metabolic panel analytes on the Abaxis Piccolo Xpress® Point of Care analyzer in serum, plasma, and whole blood. A method comparison was performed on all three specimen types intended for use on the Piccolo Xpress®: serum, heparinized plasma, and whole blood. This data is also presented in Murata et al. (2015 [1]. This article includes the actual Bland-Altman bias plots of the difference in results obtained for analytes in the comprehensive metabolic panel from the Abaxis Piccolo Xpress and the comparison instrument, the Ortho Vitros. Keywords: Clinical chemistry, Point-of care testing

  19. Analytical and numerical comparisons of the α parameter obtained from several expressions versus reactivity

    International Nuclear Information System (INIS)

    Minguez, E.

    1983-01-01

    A review of the analytical expressions between α-parameter and reactivity (rho) has been done in this article. Finally, several lineal approximations have been obtained for two important points of values. The analytical expansion has been made using only one family of precursors from delayed neutrons; diffusion equation in one energy groups; neutron flux separability with known spatial function. Numerical results have been obtained using typical data from fast and thermal reactors; considering and homogeneous media of Pu 239 in the first case, and U-235 in the second one. (author)

  20. New Analytic Solution to the Lane-Emden Equation of Index 2

    Directory of Open Access Journals (Sweden)

    S. S. Motsa

    2012-01-01

    Full Text Available We present two new analytic methods that are used for solving initial value problems that model polytropic and stellar structures in astrophysics and mathematical physics. The applicability, effectiveness, and reliability of the methods are assessed on the Lane-Emden equation which is described by a second-order nonlinear differential equation. The results obtained in this work are also compared with numerical results of Horedt (1986 which are widely used as a benchmark for testing new methods of solution. Good agreement is observed between the present results and the numerical results. Comparison is also made between the proposed new methods and existing analytical methods and it is found that the new methods are more efficient and have several advantages over some of the existing analytical methods.

  1. Comparison of analytical techniques for dynamic trace metal speciation in natural freshwaters.

    NARCIS (Netherlands)

    Sigg, Laura; Black, Frank; Buffle, Jacques; Cao, Jun; Cleven, Rob; Davison, William; Galceran, Josep; Gunkel, Peggy; Kalis, Erwin; Kistler, David; Martin, Michel; Noël, Stéphane; Nur, Yusuf; Odzak, Niksa; Puy, Jaume; Riemsdijk, Willem van; Temminghoff, Erwin; Tercier-Waeber, Mary-Lou; Toepperwien, Stefanie; Town, Raewyn M; Unsworth, Emily R; Warnken, Kent W; Weng, Liping; Xue, Hanbin; Zhang, Hao

    2006-01-01

    Several techniques for speciation analysis of Cu, Zn, Cd, Pb, and Ni are used in freshwater systems and compared with respect to their performance and to the metal species detected. The analytical techniques comprise the following: (i) diffusion gradients in thin-film gels (DGT); (ii) gel integrated

  2. Quantitative EDX microanalysis of Bi2Te3 in the TEM

    International Nuclear Information System (INIS)

    Peranio, N.; Eibl, O.

    2007-01-01

    Quantitative chemical analysis by energy dispersive X-ray spectrometry (EDX) in a transmission electron microscope (TEM) Zeiss912 and ohm; was applied to p-type (Bi,Sb) 2 Te 3 and n-type Bi 2 (Te,Se) 3 thermoelectric materials. Preliminary results yielded artifacts due to Bi spurious X-rays and hole-counts significantly beyond zero. A stray aperture was inserted in the TEM to absorb the stray radiation. With this aperture inserted a high-accuracy quantitative chemical analysis was established. The hole-counts decreased by a factor of 5 and the scatter of data decreased by a factor of 4 with respect to no aperture inserted. The mole fractions of Te and Se were 54.4 at% and 5.5 at% and varied by 0.5 at% for n-type material. A similar behaviour was found for Sb and Bi in p-type material. The variation in stoichiometry is smaller on the sub-micrometer scale and increases with increasing length scale for both, n-type and p-type Bi 2 Te 3 . Measurements in the TEM confirmed the inhomogeneous chemical composition found by wavelength dispersive X-ray spectrometry. The improved accuracy of the quantitative EDX analysis is also important for other compounds with unique physical properties. This was demonstrated on thin foils containing heavy elements and on powders of light elements dispersed on Cu-grids, i.e., the high-T C superconductor Bi 2 Sr 2 CaCu 2 O 8 and the mineral salt hydroxyapatite Ca 10 (PO 4 ) 6 OH 2 . (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  3. GenoSets: visual analytic methods for comparative genomics.

    Directory of Open Access Journals (Sweden)

    Aurora A Cain

    Full Text Available Many important questions in biology are, fundamentally, comparative, and this extends to our analysis of a growing number of sequenced genomes. Existing genomic analysis tools are often organized around literal views of genomes as linear strings. Even when information is highly condensed, these views grow cumbersome as larger numbers of genomes are added. Data aggregation and summarization methods from the field of visual analytics can provide abstracted comparative views, suitable for sifting large multi-genome datasets to identify critical similarities and differences. We introduce a software system for visual analysis of comparative genomics data. The system automates the process of data integration, and provides the analysis platform to identify and explore features of interest within these large datasets. GenoSets borrows techniques from business intelligence and visual analytics to provide a rich interface of interactive visualizations supported by a multi-dimensional data warehouse. In GenoSets, visual analytic approaches are used to enable querying based on orthology, functional assignment, and taxonomic or user-defined groupings of genomes. GenoSets links this information together with coordinated, interactive visualizations for both detailed and high-level categorical analysis of summarized data. GenoSets has been designed to simplify the exploration of multiple genome datasets and to facilitate reasoning about genomic comparisons. Case examples are included showing the use of this system in the analysis of 12 Brucella genomes. GenoSets software and the case study dataset are freely available at http://genosets.uncc.edu. We demonstrate that the integration of genomic data using a coordinated multiple view approach can simplify the exploration of large comparative genomic data sets, and facilitate reasoning about comparisons and features of interest.

  4. Ítems politómicos vs. dicotómicos : un estudio metodológico

    OpenAIRE

    López Pina, José Antonio

    2005-01-01

    En este estudio se comparan cinco formatos de respuesta para ítems politómicos, desde el formato original que consta de cuatro categorías a un formato dicotómico (sólo dos categorías de respuesta). La comparación de distintos análisis psicométricos (análisis de ítems, estudio de la fiabilidad, análisis de componentes principales y estudio de la habilidad) entre los cinco formatos prueba que un formato dicotómico aporta casi tanta información sobre la calidad del tests y las puntuaciones obser...

  5. Novel in-situ lamella fabrication technique for in-situ TEM.

    Science.gov (United States)

    Canavan, Megan; Daly, Dermot; Rummel, Andreas; McCarthy, Eoin K; McAuley, Cathal; Nicolosi, Valeria

    2018-03-29

    In-situ transmission electron microscopy is rapidly emerging as the premier technique for characterising materials in a dynamic state on the atomic scale. The most important aspect of in-situ studies is specimen preparation. Specimens must be electron transparent and representative of the material in its operational state, amongst others. Here, a novel fabrication technique for the facile preparation of lamellae for in-situ transmission electron microscopy experimentation using focused ion beam milling is developed. This method involves the use of rotating microgrippers during the lift-out procedure, as opposed to the traditional micromanipulator needle and platinum weld. Using rotating grippers, and a unique adhesive substance, lamellae are mounted onto a MEMS device for in-situ TEM annealing experiments. We demonstrate how this technique can be used to avoid platinum deposition as well as minimising damage to the MEMS device during the thinning process. Our technique is both a cost effective and readily implementable alternative to the current generation of preparation methods for in-situ liquid, electrical, mechanical and thermal experimentation within the TEM as well as traditional cross-sectional lamella preparation. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. In-situ TEM investigations of graphic-epitaxy and small particles

    Science.gov (United States)

    Heinemann, K.

    1983-01-01

    Palladium was deposited inside a controlled-vacuum specimen chamber of a transmission electron microscope (TEM) onto MgO and alpha-alumina substrate surfaces. Annealing and various effects of gas exposure of the particulate Pd deposits were studied in-situ by high resolution TEM and electron diffraction. Whereas substrate temperatures of 500 C or annealing of room temperature (RT) deposits to 500 C were needed to obtain epitaxy on sapphire, RT deposits on MgO were perfectly epitaxial. For Pd/MgO a lattice expansion of 2 to 4% was noted; the highest values of expansion were found for the smallest particles. The lattice expansion of small Pd particles on alumina substrates was less than 1%. Long-time RT exposure of Pd/MgO in a vacuum yielded some moblity and coalescence events, but notably fewer than for Pd on sapphire. Exposure to air or oxygen greatly enhanced the particle mobility and coalescence and also resulted in the flattening of Pd particles on MgO substrates. Electron-beam irradiation further enhanced this effect. Exposure to air for several tens of hours of Pd/MgO led to strong coalescence.

  7. The measurement and calculation of the X-ray spatial resolution obtained in the analytical electron microscope

    International Nuclear Information System (INIS)

    Michael, J.R.; Williams, D.B.

    1990-01-01

    The X-ray microanalytical spatial resolution is determined experimentally in various analytical electron microscopes by measuring the degradation of an atomically discrete composition profile across an interphase interface in a thin-foil of Ni-Cr-Fe. The experimental spatial resolutions are then compared with calculated values. The calculated spatial resolutions are obtained by the mathematical convolution of the electron probe size with an assumed beam-broadening distribution and the single-scattering model of beam broadening. The probe size is measured directly from an image of the probe in a TEM/SETEM and indirectly from dark-field signal changes resulting from scanning the probe across the edge of an MgO crystal in a dedicated STEM. This study demonstrates the applicability of the convolution technique to the calculation of the microanalytical spatial resolution obtained in the analytical electron microscope. It is demonstrated that, contrary to popular opinion, the electron probe size has a major impact on the measured spatial resolution in foils < 150 nm thick. (author)

  8. Complications of transanal endoscopic microsurgery (TEMS): a prospective audit.

    Science.gov (United States)

    Bignell, M B; Ramwell, A; Evans, J R; Dastur, N; Simson, J N L

    2010-07-01

    The aim of this study was to determine the postoperative complications of Transanal Endoscopic Microsurgery (TEMS) excision of rectal lesions. A prospective audit of 262 consecutive TEMS procedures performed by a single surgeon between 1999 and 2008. The mean age of patients was 72 years. The mean area of the lesions excised was 17.5 cm(2) with a mean diameter of 4.5 cm at a mean distance of 7.4 cm from the dentate line. There were 201 full thickness excisions, 51 partial thickness excisions and nine were mixed or unclassified. Thirty-three (13%) patients developed 41 complications. There were two (0.8%) deaths within 30 days. Pelvic sepsis occurred in seven (3%) patients and was significantly more common after excision of low lesions within 2 cm of the dentate line. Postoperative haemorrhage occurred in seven (3%) patients and was significantly less common when dissection was performed with ultrasonic dissection than with diathermy. Fourteen (5%) patients developed acute urinary retention. Four (1.5%) patients developed rectal stenosis and four (1.5%) suffered uncomplicated surgical emphysema that required no treatment. Transanal endoscopic microsurgery is a safe operation with a low mortality and morbidity. Pelvic sepsis is more common after excision of lesions within 2 cm of the dentate line. Ultrasonic dissection is associated with less postoperative haemorrhage than diathermy.

  9. Pythagorean fuzzy analytic hierarchy process to multi-criteria decision making

    Science.gov (United States)

    Mohd, Wan Rosanisah Wan; Abdullah, Lazim

    2017-11-01

    A numerous approaches have been proposed in the literature to determine the criteria of weight. The weight of criteria is very significant in the process of decision making. One of the outstanding approaches that used to determine weight of criteria is analytic hierarchy process (AHP). This method involves decision makers (DMs) to evaluate the decision to form the pair-wise comparison between criteria and alternatives. In classical AHP, the linguistic variable of pairwise comparison is presented in terms of crisp value. However, this method is not appropriate to present the real situation of the problems because it involved the uncertainty in linguistic judgment. For this reason, AHP has been extended by incorporating the Pythagorean fuzzy sets. In addition, no one has found in the literature proposed how to determine the weight of criteria using AHP under Pythagorean fuzzy sets. In order to solve the MCDM problem, the Pythagorean fuzzy analytic hierarchy process is proposed to determine the criteria weight of the evaluation criteria. Using the linguistic variables, pairwise comparison for evaluation criteria are made to the weights of criteria using Pythagorean fuzzy numbers (PFNs). The proposed method is implemented in the evaluation problem in order to demonstrate its applicability. This study shows that the proposed method provides us with a useful way and a new direction in solving MCDM problems with Pythagorean fuzzy context.

  10. Favorable prognosis of operable non-small cell lung cancer (NSCLC) patients harboring an increased expression of tumor endothelial markers (TEMs).

    Science.gov (United States)

    Pircher, Andreas; Fiegl, Michael; Untergasser, Gerold; Heidegger, Isabel; Medinger, Michael; Kern, Johann; Hilbe, Wolfgang

    2013-08-01

    Genome analyses of endothelial cells identified genes specifically expressed by tumor endothelial cells, called tumor endothelial markers (TEMs). Currently there are no data available concerning the role of TEMs in non-small cell lung cancer (NSCLC). Therefore, the aim of this study was to investigate the role of TEMs in NSCLC in vitro and in vivo. First we evaluated the expression of various TEMs (Robo4, Clec14 and ECSCR) by qRT-PCR and Western blot analyses in three NSCLC cell lines (A549, Calu1, Colo699) and compared them to human umbilical vein endothelial cells (HUVECs), endothelial colony forming cells (ECFCs) and human bronchial epithelial cells (HBEpCs). Next the expression of TEMs was measured in resected tumor tissue of NSCLC patients (n = 63) by qRT-PCR and compared to adjacent non-cancerous lung tissue (n = 52). Further, immunohistochemical analysis of Robo4 expression in tumor tissue (n = 33) and adjacent non-cancerous tissue (n = 27) was performed. We found that NSCLC cell lines and HBEpC did not express TEMs on the mRNA level compared to HUVECs (p = 0.001). In the contrary, a significant up-regulation of Robo4 and Clec14 was found in tumor samples (Robo4 p = 0.03, Clec14 p = 0.002). Both facts clearly indicate that these proteins are allocated to the tumor stromal department. Correlation with clinical data showed that increased TEM expression correlated with prolonged overall survival of operated NSCLC patients (Robo4 high 120.5 vs. Robo4 low 47.6 months, Clec14 high 108.1 vs. Clec14 low 54.5 months and ECSCR high 120.5 vs. ECSCR low 42.2 months). In summary, we found that TEMs are overexpressed in NSCLC stromal tissue and that an increased TEM expression correlated with an increased overall survival in early stage NSCLC. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. Analytical model for screening potential CO2 repositories

    Science.gov (United States)

    Okwen, R.T.; Stewart, M.T.; Cunningham, J.A.

    2011-01-01

    Assessing potential repositories for geologic sequestration of carbon dioxide using numerical models can be complicated, costly, and time-consuming, especially when faced with the challenge of selecting a repository from a multitude of potential repositories. This paper presents a set of simple analytical equations (model), based on the work of previous researchers, that could be used to evaluate the suitability of candidate repositories for subsurface sequestration of carbon dioxide. We considered the injection of carbon dioxide at a constant rate into a confined saline aquifer via a fully perforated vertical injection well. The validity of the analytical model was assessed via comparison with the TOUGH2 numerical model. The metrics used in comparing the two models include (1) spatial variations in formation pressure and (2) vertically integrated brine saturation profile. The analytical model and TOUGH2 show excellent agreement in their results when similar input conditions and assumptions are applied in both. The analytical model neglects capillary pressure and the pressure dependence of fluid properties. However, simulations in TOUGH2 indicate that little error is introduced by these simplifications. Sensitivity studies indicate that the agreement between the analytical model and TOUGH2 depends strongly on (1) the residual brine saturation, (2) the difference in density between carbon dioxide and resident brine (buoyancy), and (3) the relationship between relative permeability and brine saturation. The results achieved suggest that the analytical model is valid when the relationship between relative permeability and brine saturation is linear or quasi-linear and when the irreducible saturation of brine is zero or very small. ?? 2011 Springer Science+Business Media B.V.

  12. Reducing Post-Decision Dissonance in International Decisions: The Analytic Hierarchy Process Approach.

    Science.gov (United States)

    DuBois, Frank L.

    1999-01-01

    Describes use of the analytic hierarchy process (AHP) as a teaching tool to illustrate the complexities of decision making in an international environment. The AHP approach uses managerial input to develop pairwise comparisons of relevant decision criteria to efficiently generate an appropriate solution. (DB)

  13. Uranium-contaminated soils: Ultramicrotomy and electron beam analysis

    International Nuclear Information System (INIS)

    Buck, E.C.; Dietz, N.L.; Bates, J.K.; Cunnane, J.C.

    1994-02-01

    Uranium-contaminated soils from the U.S. Department of Energy (DOE) Fernald Site, Ohio, have been examined by a combination of scanning electron microscopy with backscattered electron imaging (SEM/BSE) and analytical electron microscopy (AEM). The inhomogeneous distribution of particulate uranium phases in the soil required the development of a method for using ultramicrotomy to prepare transmission electron microscopy (TEM) thin sections of the SEM mounts. A water-miscible resin was selected that allowed comparison between SEM and TEM images, permitting representative sampling of the soil. Uranium was found in iron oxides, silicates (soddyite), phosphates (autunites), and fluorite (UO 2 ). No uranium was detected in association with phyllosilicates in the soil

  14. Surface damage in TEM thick α-Fe samples by implantation with 150 keV Fe ions

    International Nuclear Information System (INIS)

    Aliaga, M.J.; Caturla, M.J.; Schäublin, R.

    2015-01-01

    We have performed molecular dynamics simulations of implantation of 150 keV Fe ions in pure bcc Fe. The thickness of the simulation box is of the same order of those used in in situ TEM analysis of irradiated materials. We assess the effect of the implantation angle and the presence of front and back surfaces. The number and type of defects, ion range, cluster distribution and primary damage morphology are studied. Results indicate that, for the very thin samples used in in situ TEM irradiation experiments the presence of surfaces affect dramatically the damage produced. At this particular energy, the ion has sufficient energy to damage both the top and the back surfaces and still leave the sample through the bottom. This provides new insights on the study of radiation damage using TEM in situ

  15. EBSD and FIB/TEM examination of shape memory effect deformation structures in U-14 at.% Nb

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, A.J. [Materials Science and Technology Division, Mail Stop G770, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)], E-mail: aclarke@lanl.gov; Field, R.D.; McCabe, R.J.; Cady, C.M.; Hackenberg, R.E.; Thoma, D.J. [Materials Science and Technology Division, Mail Stop G770, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2008-06-15

    Detailed examinations of shape memory effect (SME) deformation structures in martensite of U-14 at.% Nb were performed with electron backscatter diffraction (EBSD) and transmission electron microscopy (TEM). An accommodation strain analysis, which has been previously used to predict SME deformation structures and texture evolution in polycrystalline material, was also performed. Martensite variants and twin relationships observed with EBSD after compressive or tensile deformation were determined to be consistent with those expected from calculated accommodation strains. Focused ion beam (FIB) was used to select twinned regions identified with EBSD for more detailed TEM analysis to verify the presence of these specific twins. The observed SME twinning systems in the martensite agree with previous TEM observations and the predicted {l_brace}1-bar76{r_brace} twinning system was observed experimentally for the first time in U-14 at.% Nb using these complementary techniques.

  16. MODULAR ANALYTICS: A New Approach to Automation in the Clinical Laboratory.

    Science.gov (United States)

    Horowitz, Gary L; Zaman, Zahur; Blanckaert, Norbert J C; Chan, Daniel W; Dubois, Jeffrey A; Golaz, Olivier; Mensi, Noury; Keller, Franz; Stolz, Herbert; Klingler, Karl; Marocchi, Alessandro; Prencipe, Lorenzo; McLawhon, Ronald W; Nilsen, Olaug L; Oellerich, Michael; Luthe, Hilmar; Orsonneau, Jean-Luc; Richeux, Gérard; Recio, Fernando; Roldan, Esther; Rymo, Lars; Wicktorsson, Anne-Charlotte; Welch, Shirley L; Wieland, Heinrich; Grawitz, Andrea Busse; Mitsumaki, Hiroshi; McGovern, Margaret; Ng, Katherine; Stockmann, Wolfgang

    2005-01-01

    MODULAR ANALYTICS (Roche Diagnostics) (MODULAR ANALYTICS, Elecsys and Cobas Integra are trademarks of a member of the Roche Group) represents a new approach to automation for the clinical chemistry laboratory. It consists of a control unit, a core unit with a bidirectional multitrack rack transportation system, and three distinct kinds of analytical modules: an ISE module, a P800 module (44 photometric tests, throughput of up to 800 tests/h), and a D2400 module (16 photometric tests, throughput up to 2400 tests/h). MODULAR ANALYTICS allows customised configurations for various laboratory workloads. The performance and practicability of MODULAR ANALYTICS were evaluated in an international multicentre study at 16 sites. Studies included precision, accuracy, analytical range, carry-over, and workflow assessment. More than 700 000 results were obtained during the course of the study. Median between-day CVs were typically less than 3% for clinical chemistries and less than 6% for homogeneous immunoassays. Median recoveries for nearly all standardised reference materials were within 5% of assigned values. Method comparisons versus current existing routine instrumentation were clinically acceptable in all cases. During the workflow studies, the work from three to four single workstations was transferred to MODULAR ANALYTICS, which offered over 100 possible methods, with reduction in sample splitting, handling errors, and turnaround time. Typical sample processing time on MODULAR ANALYTICS was less than 30 minutes, an improvement from the current laboratory systems. By combining multiple analytic units in flexible ways, MODULAR ANALYTICS met diverse laboratory needs and offered improvement in workflow over current laboratory situations. It increased overall efficiency while maintaining (or improving) quality.

  17. Determination of grain size by XRD profile analysis and TEM counting in nano-structured Cu

    International Nuclear Information System (INIS)

    Zhong Yong; Ping Dehai; Song Xiaoyan; Yin Fuxing

    2009-01-01

    In this work, a serial of pure copper sample with different grain sizes from nano- to micro-scale were prepared by sparkle plasma sintering (SPS) and following anneal treatment at 873 K and 1073 K, respectively. The grain size distributions of these samples were determined by both X-ray diffraction (XRD) profile analysis and transmission electronic microscope (TEM) micrograph counting. Although these two methods give similar distributions of grain size in the case of as-SPS sample with nano-scale grain size (around 10 nm), there are apparent discrepancies between the grain size distributions of the annealed samples obtained from XRD and TEM, especially for the sample annealed at 1073 K after SPS with micro-scale grain size (around 2 μm), which TEM counting provides much higher values of grain sizes than XRD analysis does. It indicates that for large grain-sized material, XRD analysis lost its validity for determination of grain size. It might be due to some small sized substructures possibly existed in even annealed (large grain-sized) samples, whereas there is no substructures in as-SPS (nanocrystalline) sample. Moreover, it has been found that the effective outer cut-off radius R e derived from XRD analysis coincides with the grain sizes given by TEM counting. The potential relationship between grain size and R e was discussed in the present work. These results might provide some new hints for deeper understanding of the physical meaning of XRD analysis and the parameters derived.

  18. Agrupamentos epistemológicos de artigos publicados sobre big data analytics

    Directory of Open Access Journals (Sweden)

    Patricia Kuzmenko FURLAN

    Full Text Available Resumo A era do big data já é realidade para empresas e indivíduos, e a literatura acadêmica sobre o tema tem crescido rapidamente nos últimos anos. Neste artigo, pretendeu-se identificar quais são os principais nichos e vertentes de publicação sobre o big data analytics. A opção metodológica foi realizar pesquisa bibliométrica na base de dados ISI Web of Science, utilizando-se aquele termo para focar as práticas de gestão de big data. Foi possível identificar cinco grupos distintos dentre os artigos encontrados: evolução do big data; gestão, negócios e estratégia; comportamento humano e aspectos socioculturais; mineração dos dados (data mining e geração de conhecimento; e Internet das Coisas. Concluiu-se que o tema é emergente e pouco consolidado, apresentando grande variação nos termos empregados, o que influencia nas buscas bibliográficas. Como resultado complementar da pesquisa, foram identificadas as principais palavras-chave empregadas nas publicações sobre big data analytics, o que contribui para as pesquisas bibliográficas de estudos futuros.

  19. Comparison of nuclear safety research reactor (TRIGA-ACPR) performance with analytical prediction

    International Nuclear Information System (INIS)

    West, G.B.; Whittemore, W.L.

    1976-01-01

    The NSRR was taken critical on June 30, 1975 at the Japan Atomic Energy Research Institute - Tokai-mura, Japan. Following initial core loading and control rod calibration, a series of pulsing tests was performed to characterize the performance of the reactor. A comparison has been made of performance parameters actually measured in the 157 element core versus predicted values based upon design analyses. The nuclear parameters measured were quite close to prediction. A $4.70 pulse produced a minimum period of 1.12 msec, a peak power of 20,500 MW and yielded a prompt energy release of 103 MW-sec. Pulse tests with experimental UO 2 fuel pins in the central irradiation cavity have produced 320 cal/gm, averaged at the axial center of 10% enriched UO 2 , for a 100 MW-sec pulse. The pulse rods for the NSRR contain B 4 C enriched to about 93 percent in Boron-10 in order to achieve maximum design performance with only three pulse rods. The total worth for the three transient rods was measured to be about $5.05 (vs $5.07 calculated for the 165 element core), thus verifying the effectiveness of the Boron-10 enrichment to achieve the desired result. Analysis of fuel temperature measurements made in the NSRR show that, for fuel temperatures produced during pulsing greater than 900 deg. C, heat transfer in the 0.010-inch gap between fuel and clad is enhanced by the minor outgassing of hydrogen which is characteristic of that temperature region. The hydrogen is normally all reabsorbed within about 100 sec of maximum temperature, at which time the heat transfer is characteristic of air (or argon) in the gap. In some of the temperature-instrumented elements, however, all of the hydrogen was not reabsorbed and as a result these elements gave significantly lower temperatures for high power steady state operation than were recorded prior to pulsing. In general, the NSRR parameters measured during startup were quite close to analytical prediction and the overall performance of the

  20. Geological Hypothesis Testing and Investigations of Coupling with Transient Electromagnetics (TEM)

    Science.gov (United States)

    Adams, A. C.; Moeller, M. M.; Snyder, E.; Workman, E. J.; Urquhart, S.; Bedrosian, P.; Pellerin, L.

    2014-12-01

    Transient electromagnetic (TEM) data were acquired in Borrego Canyon within the Santo Domingo Basin of the Rio Grande Rift, central New Mexico, during the 2014 Summer of Applied Geophysical Experience (SAGE) field program. TEM surveys were carried out in several regions both to investigate geologic structure and to illustrate the effects of coupling to anthropogenic structures. To determine an optimal survey configuration, 50, 100 and 200 m square transmitter loops were deployed; estimates of depth-of-investigation and logistical considerations determined that 50 m loops were sufficient for production-style measurements. A resistive (100s of ohm-m) layer was identified at a depth of 25-75 m at several locations, and interpreted as dismembered parts of one or more concealed volcanic flows, an interpretation consistent with Tertiary volcanic flows that cap the Santa Anna Mesa immediately to the south. TEM soundings were also made across an inferred fault to investigate whether fault offset is accompanied by lateral changes in electrical resistivity. Soundings within several hundred meters of the inferred fault strand were identical, indicating no resistivity contrast across the fault, and possibly an absence of recent activity. An old windmill and water tank, long-abandoned, offered an excellent laboratory to study the effect of coupling to metallic anthropogenic structures. The character of the measured data strongly suggests the water tank is in electrical contact with the earth (galvanic coupling), and an induced response was persistent to more than 1 second after current turn-off. Coupling effects could be identified at least 150 meters from the tank. Understanding the mechanism behind such coupling and the ability to identify coupled data are critical skills, as one-dimensional modeling of data is affected by such coupling producing artificial conductive layers at depth.

  1. Educación mediante enciclopedias visuales temáticas: INTYPEDIA un caso de éxito.

    OpenAIRE

    Ramió Aguirre, Jorge; Muñoz Muñoz, Alfonso

    2013-01-01

    La presente investigación recoge una experiencia de innovación educativa que demuestra la utilidad de las enciclopedias visuales temáticas para la formación académica a través de Internet. Los objetivos de esta experiencia recaen en verificar si es posible crear enciclopedias visuales temáticas que mediante recursos audiovisuales permitan el aprendizaje de aspectos complejos de una manera asequible. Con el interés de obtener datos que permitan comprobar la idoneidad de este tipo de recursos f...

  2. El juego temático de roles sociales: aportes al desarrollo en la edad preescolar

    OpenAIRE

    González Moreno, Claudia Ximena; Solovieva, Yulia; Quintanar Rojas, Luis

    2014-01-01

    El juego temático de roles sociales es importante en la educación inicial porque posibilita el desarrollo de la actividad simbólica, voluntaria, reflexiva, comunicativa desplegada e imaginativa. Estas son formaciones psicológicas que garantizan el aprendizaje en la edad escolar. En este artículo se presenta una reflexión acerca de la necesidad de utilizar el juego temático de roles sociales en las aulas de preescolar,1 por su efecto en la promoción de habilidades y en la prevención de dificul...

  3. Cross section TEM characterization of high-energy-Xe-irradiated U-Mo

    Energy Technology Data Exchange (ETDEWEB)

    Ye, B., E-mail: bye@anl.gov [Nuclear Engineering Division, Argonne National Laboratory, 9700 S. Cass Ave. Lemont, IL 60439 (United States); Jamison, L.; Miao, Y. [Nuclear Engineering Division, Argonne National Laboratory, 9700 S. Cass Ave. Lemont, IL 60439 (United States); Bhattacharya, S. [Department of Materials Science and Engineering, Northwestern University, 2220 Campus Dr. Evanston, IL 60208 (United States); Hofman, G.L.; Yacout, A.M. [Nuclear Engineering Division, Argonne National Laboratory, 9700 S. Cass Ave. Lemont, IL 60439 (United States)

    2017-05-15

    U-Mo alloys irradiated with 84 MeV Xe ions to various doses were characterized with transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) techniques. The TEM thin foils were prepared perpendicular to the irradiated surface to allow a direct observation of the entire region modified by ions. Therefore, depth-selective microstructural information was revealed. Varied irradiation-induced phenomena such as gas bubble formation, phase reversal, and recrystallization were observed at different ion penetration depths in U-Mo. - Highlights: •Three distinct zones were observed along the ion traveling direction in U-7Mo irradiated with 84 MeV Xe ions at 350 °C. •The α-U particles within the Xe-implanted region were reverted to γ-U phase by irradiation. •High-density random intra-granular bubbles in a size of 4–5 nm were found in the irradiated region, coexisting with large inter-granular bubbles. •The high lattice stresses built up during the irradiation-induced phase reversal is probably the driving force for the small grain formation at cell boundaries.

  4. Doctoral Program Selection Using Pairwise Comparisons.

    Science.gov (United States)

    Tadisina, Suresh K.; Bhasin, Vijay

    1989-01-01

    The application of a pairwise comparison methodology (Saaty's Analytic Hierarchy Process) to the doctoral program selection process is illustrated. A hierarchy for structuring and facilitating the doctoral program selection decision is described. (Author/MLW)

  5. Analytical program: 1975 Bikini radiological survey

    International Nuclear Information System (INIS)

    Mount, M.E.; Robison, W.L.; Thompson, S.E.; Hamby, K.O.; Prindle, A.L.; Levy, H.B.

    1976-01-01

    The analytical program for samples of soil, vegetation, and animal tissue collected during the June 1975 field survey of Bikini and Eneu islands is described. The phases of this program are discussed in chronological order: initial processing of samples, gamma spectrometry, and wet chemistry. Included are discussions of quality control programs, reproducibility of measurements, and comparisons of gamma spectrometry with wet chemistry determinations of 241 Am. Wet chemistry results are used to examine differences in Pu:Am ratios and Pu-isotope ratios as a function of the type of sample and the location where samples were collected

  6. Environmental TEM in an Aberration Corrected Microscope

    DEFF Research Database (Denmark)

    Hansen, Thomas Willum; Wagner, Jakob Birkedal

    ‐resolution imaging. A gaseous atmosphere in the pole‐piece gap of the objective lens of the microscope alters both the incoming electron wave prior to interaction with the sample and the outgoing wave below the sample. Whereas conventional TEM samples are usually thin (below 10‐20 nm), the gas in the environmental...... the microscope column. The effects of gas on the electron wave in the objective lens are not well understood and needs further attention. Imaging samples with a simple geometry, such as gold particles on a flat graphene substrate and analyzing the variations in contrast, provides a means for understanding...... results from imaging in various elemental as well as di‐molecular gases and their effect on imaging and spectroscopy in the environmental transmission electron microscope....

  7. Programs and analytical methods for the U.S. Geological Survey acid-rain quality-assurance project. Water Resources Investigation

    International Nuclear Information System (INIS)

    See, R.B.; Willoughby, T.C.; Brooks, M.H.; Gordon, J.D.

    1990-01-01

    The U.S. Geological Survey operates four programs to provide external quality-assurance of wet deposition monitoring by the National Atmospheric Deposition Program and the National Trends Network. An intersite-comparison program assesses the precision and bias of onsite determinations of pH and specific conductance made by site operators. A blind-audit program is used to assess the effect of routine sample-handling procedures and transportation on the precision and bias of wet-deposition data. An interlaboratory-comparison program is used to assess analytical results from three or more laboratories, which routinely analyze wet-deposition samples from the major North American networks, to determine if comparability exists between laboratory analytical results and to provide estimates of the analytical precision of each laboratory. A collocated-sampler program is used to estimate the precision of wet/dry precipitation sampling throughout the National Atmospheric Deposition Program and the National Trends Network, to assess the variability of diverse spatial arrays, and to evaluate the impact of violations of specific site criteria. The report documents the procedures and analytical methods used in these four quality-assurance programs

  8. The electric field induced by transcranial magnetic stimulation: A comparison between analytic and fem solutions

    Directory of Open Access Journals (Sweden)

    Porzig Konstantin

    2014-01-01

    Full Text Available The induced electric field profiles in a homogeneous isotropic sphere, were calculated and compared between an analytic and a finite-element method in the framework of transcranial magnetic stimulation (TMS. This model can also be applied for concentric spheres in the framework of magnetic induction tomography (MIT, non destructive testing (NDT or to calculate the lead field in magnetoencephalography (MEG. The calculations were performed using Eaton’s method as well as the finite-element program Comsol Multiphysics 4.2a (COMSOL Inc., Burlington, USA. A circular- and a figure-of-8 coil were used to operate as the sources of excitation. In our study the spherical volume conductor represents the human head consisting of grey matter. In order to quantify the differences between both methods an intense parameter study was performed. A comparison between both methods show a higher conformity than reported in previous studies. Regarding Eaton’s method, the influence of the maximum order of approximation L and the number of elements per winding K was investigated. The maximum relative difference was approximately 0.3% for L = 20 and K > 16. Furthermore the relative efficiency of the algorithm was calculated to save computational time. With the presented results it is possible to use Eaton’s method efficiently to compute the induced electric field profiles very quickly for example while searching for specific coil arrangements around the humans head, as in the case of deep brain transcranial magnetic stimulation (dTMS.

  9. Analytic models for the evolution of semilocal string networks

    International Nuclear Information System (INIS)

    Nunes, A. S.; Martins, C. J. A. P.; Avgoustidis, A.; Urrestilla, J.

    2011-01-01

    We revisit previously developed analytic models for defect evolution and adapt them appropriately for the study of semilocal string networks. We thus confirm the expectation (based on numerical simulations) that linear scaling evolution is the attractor solution for a broad range of model parameters. We discuss in detail the evolution of individual semilocal segments, focusing on the phenomenology of segment growth, and also provide a preliminary comparison with existing numerical simulations.

  10. Triangular dislocation: an analytical, artefact-free solution

    Science.gov (United States)

    Nikkhoo, Mehdi; Walter, Thomas R.

    2015-05-01

    Displacements and stress-field changes associated with earthquakes, volcanoes, landslides and human activity are often simulated using numerical models in an attempt to understand the underlying processes and their governing physics. The application of elastic dislocation theory to these problems, however, may be biased because of numerical instabilities in the calculations. Here, we present a new method that is free of artefact singularities and numerical instabilities in analytical solutions for triangular dislocations (TDs) in both full-space and half-space. We apply the method to both the displacement and the stress fields. The entire 3-D Euclidean space {R}3 is divided into two complementary subspaces, in the sense that in each one, a particular analytical formulation fulfils the requirements for the ideal, artefact-free solution for a TD. The primary advantage of the presented method is that the development of our solutions involves neither numerical approximations nor series expansion methods. As a result, the final outputs are independent of the scale of the input parameters, including the size and position of the dislocation as well as its corresponding slip vector components. Our solutions are therefore well suited for application at various scales in geoscience, physics and engineering. We validate the solutions through comparison to other well-known analytical methods and provide the MATLAB codes.

  11. Localised corrosion in aluminium alloy 2024-T3 using in situ TEM

    NARCIS (Netherlands)

    Malladi, S.; Shen, C.; Xu, Q.; De Kruijff, T.; Yücelen, E.; Tichelaar, F.; Zandbergen, H.

    2013-01-01

    An approach to carry out chemical reactions using aggressive gases in situ in a transmission electron microscope (TEM), at ambient pressures of 1.5 bar using a windowed environmental cell, called a nanoreactor, is presented here. The nanoreactor coupled with a specially developed holder with

  12. An Analysis of Air Force Management of Turbine Engine Monitoring Systems (TEMS).

    Science.gov (United States)

    1980-06-01

    Without their candid insights, this study could not have been completed. The guidance and patience of our thesis chairman, Major Leslie Zambo , whose...its own problems and looking at own piece of the pie . 2. No integration/standardization between TEMS programs. 3. Need better organizational

  13. A shipboard comparison of analytic methods for ballast water compliance monitoring

    Science.gov (United States)

    Bradie, Johanna; Broeg, Katja; Gianoli, Claudio; He, Jianjun; Heitmüller, Susanne; Curto, Alberto Lo; Nakata, Akiko; Rolke, Manfred; Schillak, Lothar; Stehouwer, Peter; Vanden Byllaardt, Julie; Veldhuis, Marcel; Welschmeyer, Nick; Younan, Lawrence; Zaake, André; Bailey, Sarah

    2018-03-01

    Promising approaches for indicative analysis of ballast water samples have been developed that require study in the field to examine their utility for determining compliance with the International Convention for the Control and Management of Ships' Ballast Water and Sediments. To address this gap, a voyage was undertaken on board the RV Meteor, sailing the North Atlantic Ocean from Mindelo (Cape Verde) to Hamburg (Germany) during June 4-15, 2015. Trials were conducted on local sea water taken up by the ship's ballast system at multiple locations along the trip, including open ocean, North Sea, and coastal water, to evaluate a number of analytic methods that measure the numeric concentration or biomass of viable organisms according to two size categories (≥ 50 μm in minimum dimension: 7 techniques, ≥ 10 μm and scientific approaches (e.g. flow cytometry). Several promising indicative methods were identified that showed high correlation with microscopy, but allow much quicker processing and require less expert knowledge. This study is the first to concurrently use a large number of analytic tools to examine a variety of ballast water samples on board an operational ship in the field. Results are useful to identify the merits of each method and can serve as a basis for further improvement and development of tools and methodologies for ballast water compliance monitoring.

  14. Evaluation of TEG(®) and RoTEM(®) inter-changeability in trauma patients.

    Science.gov (United States)

    Hagemo, Jostein S; Næss, Paal A; Johansson, Pär; Windeløv, Nis A; Cohen, Mitchell Jay; Røislien, Jo; Brohi, Karim; Heier, Hans Erik; Hestnes, Morten; Gaarder, Christine

    2013-05-01

    Massive haemorrhage is a leading cause of preventable deaths in trauma. Traumatic coagulopathy is frequently present early after trauma, and is associated with increased mortality. A number of recent trials suggest that viscoelastic haemostatic assays (VHA), such as thromboelastography and thromboelastometry, are useful tools in guiding transfusion. Treatment algorithms exist for the use of VHAs but are not validated in traumatic haemorrhage. In this study we examined the inter-changeability of two commonly used VHAs, TEG(®) and RoTEM(®). A total of 184 trauma patients over the age of 18, requiring full trauma team activation, were included at three different hospitals in three different countries (Copenhagen, Denmark, San Francisco, CA, USA and Oslo, Norway). Blood samples were drawn immediately upon arrival, and TEG(®) and RoTEM(®) analyzed simultaneously. Correlations were calculated using. Spearman's rank correlation coefficient. Agreement was evaluated by Bland-Altman plots and calculation of limits of agreement. The mean ISS in the total population was 17, and the mortality was 16.5%. Mean base excess was -2.8 (SD: 4.2). The correlation coefficient for corresponding values for the two devices was 0.24 for the R-time vs CT in all centres combined. For the K-time vs CFT the correlation was 0.48, for the α-angleTEG vs α-angleRoTEM 0.44, and for MA vs MCF 0.76. Limits of agreement exceeded the preset clinically acceptable deviation of 10% for all variables in all centres except for MA/MCF in one centre (Copenhagen). Generally, correlation coefficients were lower and agreement poorer in the one centre (Oslo) where measurements were performed bedside by clinicians. Inter-changeability between TEG(®) and RoTEM(®) is limited in the trauma setting. Agreement seems poorer when clinicians operate the devices. Development and validation of separate treatment algorithms for the two devices is required. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Web Analytics

    Science.gov (United States)

    EPA’s Web Analytics Program collects, analyzes, and provides reports on traffic, quality assurance, and customer satisfaction metrics for EPA’s website. The program uses a variety of analytics tools, including Google Analytics and CrazyEgg.

  16. In Situ Environmental TEM in Imaging Gas and Liquid Phase Chemical Reactions for Materials Research.

    Science.gov (United States)

    Wu, Jianbo; Shan, Hao; Chen, Wenlong; Gu, Xin; Tao, Peng; Song, Chengyi; Shang, Wen; Deng, Tao

    2016-11-01

    Gas and liquid phase chemical reactions cover a broad range of research areas in materials science and engineering, including the synthesis of nanomaterials and application of nanomaterials, for example, in the areas of sensing, energy storage and conversion, catalysis, and bio-related applications. Environmental transmission electron microscopy (ETEM) provides a unique opportunity for monitoring gas and liquid phase reactions because it enables the observation of those reactions at the ultra-high spatial resolution, which is not achievable through other techniques. Here, the fundamental science and technology developments of gas and liquid phase TEM that facilitate the mechanistic study of the gas and liquid phase chemical reactions are discussed. Combined with other characterization tools integrated in TEM, unprecedented material behaviors and reaction mechanisms are observed through the use of the in situ gas and liquid phase TEM. These observations and also the recent applications in this emerging area are described. The current challenges in the imaging process are also discussed, including the imaging speed, imaging resolution, and data management. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. TEM microstructural characterization of melt-spun aged Al-6Si-3Cu-xMg alloys

    International Nuclear Information System (INIS)

    Lopez, Ismeli Alfonso; Zepeda, Cuauhtemoc Maldonado; Gonzalez Reyes, Jose Gonzalo; Flores, Ariosto Medina; Rodriguez, Juan Serrato; Gomez, Luis Bejar

    2007-01-01

    Three Al-6Si-3Cu-xMg alloys (x = 0.59, 3.80 and 6.78 wt.%) were produced using melt-spinning. As-melt-spun ribbons were aged at 150, 180 and 210 deg. C for times between 0.05 and 100 h. Microstructural changes were examined using transmission electron microscopy (TEM) and microhardness was measured. TEM analysis of the as-melt-spun alloys revealed 5 nm nanoparticles and larger particles (50 nm) composed of Al 2 Cu (θ) for the 0.59% Mg alloy and Al 5 Cu 2 Mg 8 Si 6 (Q) for 3.80% and 6.78% Mg alloys. Silicon solid solubility was extended to 9.0 at.% and Mg in solid solution reached 6.7 at.%. After aging treatments the 6.78% Mg alloy exhibited the most significant increase in microhardness, reaching 260 kg/mm 2 . TEM analysis of aged specimens also showed θ and Q phase (5-20 nm nanoparticles and 35-40 nm particles). The combination of the volume fraction and size of the particles plays an important role in microhardness variation

  18. Environmental TEM in the in situ Toolbox

    DEFF Research Database (Denmark)

    Wagner, Jakob Birkedal

    on complementary experiments and characterization techniques. Normally, this is done in parallel with experiments separated in time and space [1] or mimicking a reaction by changing the conditions according to e.g. reactivity and conversion measured in dedicated catalyst set-ups [2]. Furthermore, dedicated...... the techniques to the microscope. A dedicated custom TEM specimen holder containing two optical fibres, five electrical contacts, a fixed miniaturized optical bench for light handling and a heating element has been designed. A system of pre-aligned mirrors and a MEMS heater are implemented in the holder...

  19. TEM INVESTIGATIONS OF WC-Co ALLOYS AFTER CREEP EXPERIMENTS

    OpenAIRE

    Lay , S.; Osterstock , F.; Vicens , J.

    1986-01-01

    Carbide tungsten cobalt alloys were deformed in compression or in three point bending in a temperature range 1000-1350°C and in a stress domain 30-1000MPa. In these conditions, the stress exponent n of WC-Co alloys is a function of only the cobalt volumic ratio and tends towards n = 1 for pure carbide. The apparent activation energy is 550 kj mole-1. T.E.M. investigations on pure carbide deformed at 1450°C show an extensive intragranular deformation. Analysis of these defects have been perfor...

  20. Shear Punch Testing of BOR-60 Irradiated TEM Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Saleh, Tarik A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Quintana, Matthew Estevan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Tobias J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-13

    As a part of the project “High Fidelity Ion Beam Simulation of High Dose Neutron Irradiation” an Integrated Research Program (IRP) project from the U.S. Department of Energy, Nuclear Energy University Programs (NEUP), TEM geometry samples of ferritic cladding alloys, Ni based super alloys and model alloys were irradiated in the BOR-60 reactor to ~16 dpa at ~370°C and ~400°C. Samples were sent to Los Alamos National Laboratory and subjected to shear punch testing. This report presents the results from this testing.

  1. Towards 3D crystal orientation reconstruction using automated crystal orientation mapping transmission electron microscopy (ACOM-TEM).

    Science.gov (United States)

    Kobler, Aaron; Kübel, Christian

    2018-01-01

    To relate the internal structure of a volume (crystallite and phase boundaries) to properties (electrical, magnetic, mechanical, thermal), a full 3D reconstruction in combination with in situ testing is desirable. In situ testing allows the crystallographic changes in a material to be followed by tracking and comparing the individual crystals and phases. Standard transmission electron microscopy (TEM) delivers a projection image through the 3D volume of an electron-transparent TEM sample lamella. Only with the help of a dedicated TEM tomography sample holder is an accurate 3D reconstruction of the TEM lamella currently possible. 2D crystal orientation mapping has become a standard method for crystal orientation and phase determination while 3D crystal orientation mapping have been reported only a few times. The combination of in situ testing with 3D crystal orientation mapping remains a challenge in terms of stability and accuracy. Here, we outline a method to 3D reconstruct the crystal orientation from a superimposed diffraction pattern of overlapping crystals without sample tilt. Avoiding the typically required tilt series for 3D reconstruction enables not only faster in situ tests but also opens the possibility for more stable and more accurate in situ mechanical testing. The approach laid out here should serve as an inspiration for further research and does not make a claim to be complete.

  2. Coupling impedance of an in-vacuum undulator: Measurement, simulation, and analytical estimation

    Science.gov (United States)

    Smaluk, Victor; Fielder, Richard; Blednykh, Alexei; Rehm, Guenther; Bartolini, Riccardo

    2014-07-01

    One of the important issues of the in-vacuum undulator design is the coupling impedance of the vacuum chamber, which includes tapered transitions with variable gap size. To get complete and reliable information on the impedance, analytical estimate, numerical simulations and beam-based measurements have been performed at Diamond Light Source, a forthcoming upgrade of which includes introducing additional insertion device (ID) straights. The impedance of an already existing ID vessel geometrically similar to the new one has been measured using the orbit bump method. The measurement results in comparison with analytical estimations and numerical simulations are discussed in this paper.

  3. The Case for Adopting Server-side Analytics

    Science.gov (United States)

    Tino, C.; Holmes, C. P.; Feigelson, E.; Hurlburt, N. E.

    2017-12-01

    The standard method for accessing Earth and space science data relies on a scheme developed decades ago: data residing in one or many data stores must be parsed out and shipped via internet lines or physical transport to the researcher who in turn locally stores the data for analysis. The analyses tasks are varied and include visualization, parameterization, and comparison with or assimilation into physics models. In many cases this process is inefficient and unwieldy as the data sets become larger and demands on the analysis tasks become more sophisticated and complex. For about a decade, several groups have explored a new paradigm to this model. The names applied to the paradigm include "data analytics", "climate analytics", and "server-side analytics". The general concept is that in close network proximity to the data store there will be a tailored processing capability appropriate to the type and use of the data served. The user of the server-side analytics will operate on the data with numerical procedures. The procedures can be accessed via canned code, a scripting processor, or an analysis package such as Matlab, IDL or R. Results of the analytics processes will then be relayed via the internet to the user. In practice, these results will be at a much lower volume, easier to transport to and store locally by the user and easier for the user to interoperate with data sets from other remote data stores. The user can also iterate on the processing call to tailor the results as needed. A major component of server-side analytics could be to provide sets of tailored results to end users in order to eliminate the repetitive preconditioning that is both often required with these data sets and which drives much of the throughput challenges. NASA's Big Data Task Force studied this issue. This paper will present the results of this study including examples of SSAs that are being developed and demonstrated and suggestions for architectures that might be developed for

  4. Comparison between laboratory measurements, simulations, and analytical predictions of the transverse wall impedance at low frequencies

    CERN Document Server

    Roncarolo, F; Kroyer, T; Metral, E; Mounet, N; Salvant, B; Zotter, B

    2009-01-01

    The prediction of the transverse wall beam impedance at the first unstable betatron line (8 kHz) of the CERN Large Hadron Collider (LHC) is of paramount importance for understanding and controlling the related coupled-bunch instabilities. Until now only novel analytical formulas were available at this frequency. Recently, laboratory measurements and numerical simulations were performed to cross-check the analytical predictions. The experimental results based on the measurement of the variation of a probe coil inductance in the presence of (i) sample graphite plates, (ii) stand-alone LHC collimator jaws, and (iii) a full LHC collimator assembly are presented in detail. The measurement results are compared to both analytical theories and simulations. In addition, the consequences for the understanding of the LHC impedance are discussed.

  5. Investigation of C3 S hydration mechanism by transmission electron microscope (TEM) with integrated Super-XTM EDS system.

    Science.gov (United States)

    Sakalli, Y; Trettin, R

    2017-07-01

    Tricalciumsilicate (C 3 S, Alite) is the major component of the Portland cement clinker. Hydration of Alite is decisive in influencing the properties of the resulting material. This is due to its high content in cement. The mechanism of the hydration of C 3 S is very complicated and not yet fully understood. There are different models describing the hydration of C 3 S in various ways. In this work for a better understanding of hydration mechanism, the hydrated C 3 S was investigated by using the transmission electron microscope (TEM) and for the first time, the samples for the investigations were prepared by using of focused ion beam from sintered pellets of C 3 S. Also, an FEI Talos F200x with an integrated Super-X EDS system was used for the investigations. FEI Talos F200X combines outstanding high-resolution S/TEM and TEM imaging with energy dispersive X-ray spectroscopy signal detection, and 3D chemical characterization with compositional mapping. TEM is a very powerful tool for material science. A high energy beam of electrons passes through a very thin sample, and the interactions between the electrons and the atoms can be used to observe the structure of the material and other features in the structure. TEM can be used to study the growth of layers and their composition. TEM produces high-resolution, two-dimensional images and will be used for a wide range of educational, science and industry applications. Chemical analysis can also be performed. The purpose of these investigations was to get the information about the composition of the C-S-H phases and some details of the nanostructure of the C-S-H phases. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  6. Lessons learnt from participation in international inter-comparison exercise for environmental radioactivity measurement

    International Nuclear Information System (INIS)

    Jha, S.K.; Pulhani, Vandana; Sartandel, Sangeeta

    2016-06-01

    Environmental Radioactivity Measurement Section of Health Physics Division is regularly carrying out surveillance of the radioactivity concentration in the environment. The laboratory participates in the inter-comparison exercises conducted by various international agencies for quality assurance and quality control of analytical estimations. This report summarizes the results of the analysis of radioactivity in environmental matrices of the inter-comparison exercises. The participation in inter-comparison exercises has demonstrated competence in radionuclide identification and estimations, equivalence with the results of other participating laboratories, validated adopted analytical methods, introduced traceability to measurement etc. at national and international level. (author)

  7. Comparison of the layer structure of vapor phase and leached SRL glass by use of AEM [analytical electron microscopy

    International Nuclear Information System (INIS)

    Biwer, B.M.; Bates, J.K.; Abrajano, T.A. Jr.; Bradley, J.P.

    1989-01-01

    Test samples of 131 type glass that have been reacted for extended time periods in water vapor atmospheres of different relative humidities and in static leaching solution have been examined to characterize the reaction products. Analytical electron microscopy (AEM) was used to characterize the leached samples, and a complicated layer structure was revealed, consisting of phases that precipitate from solution and also form within the residual glass layer. The precipitated phases include birnes-site, saponite, and an iron species, while the intralayer phases include the U-Ti containing phase brannerite distributed within a matrix consisting of bands of an Fe rich montmorillonite clay. Comparison is made between samples leached at 40 degrees C for 4 years with those leached at 90 degrees C for 3-1/2 years. The samples reacted in water vapor were examined with scanning electron microscopy and show increasing reaction as both the relative humidity and time of reaction increases. These samples also contain a layered structure with reaction products on the glass surface. 15 refs., 5 figs

  8. Properties of TEM standing waves with E||B

    Science.gov (United States)

    Zaghloul, H.; Buckmaster, H. A.

    This paper summarizes the known properties of E∥B TEM standing waves and shows that for such waves (i) E and B cannot be linearly polarized, (ii) E ≠ αB where α is a constant (iii) it is impossible to find a Lorentz frame where E>B, (iv) direction of the propagation vector cannot be inferred from the fields at one point of the space, (v) their behaviour under Lorentz, parity, time-reversal and gauge transformations is proper, (vi) both Lorentz invariants E2 - B2 and E·B are nonzero, (vii) the magnetic helicity may be nonzero, (viii) the magnetic field may be force-free, and (ix) kμFμv ≠ 0. It also shows how electromagnetic waves can be classified using Lorentz invariants. Cet article résume les qualités connues des ondes stationnaires E∥B TEM et montre que pour des ondes parallèles (i) E et B ne peuvent pas être polarisées linéairement, (ii) E ≠ αB où a est une constante, (iii) il est impossible de trouver une construction de Lorentz où E>B, (iv) la direction de propagation d'un vecteur ne peut pas être déduite des opérations à un point d'intervalle, (v) leur conduite sous Lorentz, parité, temps inverse et transformations de jauge est propre, (vi) les deux invariants de Lorentz E2 - B2 et E·B sont non nulles (vii) l'hélice magnétique peut être non nulle (viii) l'opération magnétique peut être de force libre et (ix) KμFμ v ≠ 0. Ceci montre aussi comment les ondes électromagnétiques peuvent être classifiées, en employant les invariants de Lorentz.

  9. SANS and TEM studies of carbide precipitation and creep damage in type 304 stainless steel

    International Nuclear Information System (INIS)

    Yoo, M.H.; Ogle, J.C.; Schneibel, J.H.; Swindeman, R.W.

    1984-01-01

    Small-angle neutron scattering (SANS) and transmission electron microscopy (TEM) studies were performed to characterize the carbide (M 23 C 6 ) precipitation and creep damage induced in type 304 stainless steel in the primary creep stage. The size distribution of matrix carbides evaluated from SANS analyses was consistent with TEM data, and the expected accelerated kinetics of precipitation under applied stress was confirmed. Additional SANS measurements after the postcreep solution annealing were made in order to differentiate cavities from the carbides. Potential advantages and difficulties associated with characterization of creep-induced cavitation by the SANS techniques are discussed

  10. A Method for Individualizing the Prediction of Immunogenicity of Protein Vaccines and Biologic Therapeutics: Individualized T Cell Epitope Measure (iTEM

    Directory of Open Access Journals (Sweden)

    Tobias Cohen

    2010-01-01

    Full Text Available The promise of pharmacogenomics depends on advancing predictive medicine. To address this need in the area of immunology, we developed the individualized T cell epitope measure (iTEM tool to estimate an individual's T cell response to a protein antigen based on HLA binding predictions. In this study, we validated prospective iTEM predictions using data from in vitro and in vivo studies. We used a mathematical formula that converts DRB1∗ allele binding predictions generated by EpiMatrix, an epitope-mapping tool, into an allele-specific scoring system. We then demonstrated that iTEM can be used to define an HLA binding threshold above which immune response is likely and below which immune response is likely to be absent. iTEM's predictive power was strongest when the immune response is focused, such as in subunit vaccination and administration of protein therapeutics. iTEM may be a useful tool for clinical trial design and preclinical evaluation of vaccines and protein therapeutics.

  11. Analytical torque calculation and experimental verification of synchronous permanent magnet couplings with Halbach arrays

    Science.gov (United States)

    Seo, Sung-Won; Kim, Young-Hyun; Lee, Jung-Ho; Choi, Jang-Young

    2018-05-01

    This paper presents analytical torque calculation and experimental verification of synchronous permanent magnet couplings (SPMCs) with Halbach arrays. A Halbach array is composed of various numbers of segments per pole; we calculate and compare the magnetic torques for 2, 3, and 4 segments. Firstly, based on the magnetic vector potential, and using a 2D polar coordinate system, we obtain analytical solutions for the magnetic field. Next, through a series of processes, we perform magnetic torque calculations using the derived solutions and a Maxwell stress tensor. Finally, the analytical results are verified by comparison with the results of 2D and 3D finite element analysis and the results of an experiment.

  12. ZFITTER - an analytical program for fermion-pair production

    International Nuclear Information System (INIS)

    Riemann, T.

    1992-10-01

    I discuss the semi-analytical codes which have been developed for the Z line-shape analysis at LEP I. They are applied for a model-independent and, when using a weak library, a Standard Model interpretation of the data. Some of them are applicable for New Physics searches. The package ZF I TT ER serves as an example, and comparisons of the codes are discussed. The degrees of freedom of the line shape and of asymmetries are made explicit. (orig.)

  13. Transanal endoscopic micro-surgery (TEMS) for the management of large or sessile rectal adenomas: a review of the technique and indications.

    Science.gov (United States)

    Papagrigoriadis, Savvas

    2006-05-04

    In this review article the surgical technique of Transanal Endoscopic Microsurgery (TEMS) is examined. A number of techniques have been used to treat adenomas of the rectum. The treatment of large adenomas which occupy a large surface of the rectal lumen or adenomas which are flat and grow in a "carpet-like" fashion is particularly challenging. Major rectal surgery carries a risk of morbidity and mortality, particularly in elderly and unfit patients. Although local excision with transanal resection (TAR) and the Kraske sacral operation have been used in the past, during the last twenty years TEMS has become the method of choice for those lesions. TEMS is efficient and minimally invasive. The technique allows the patient to recover rapidly and the incidence of complications is much lower than that of major surgery. In case of recurrence the option of repeat TEMS or major surgery remain available. TEMS has been slow to gain popularity mainly for reasons of cost and steep learning curve but it is now an established procedure and a valuable therapeutic option which is particularly useful for elderly and unfit patients. Gastroenterologists should be aware of the nature and indications of TEMS in order to advise and refer selected patients with rectal adenomas accordingly.

  14. 42 CFR 493.1281 - Standard: Comparison of test results.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Comparison of test results. 493.1281 Section 493.1281 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the...

  15. Application of SEM/EBSD and FEG-TEM/CBED to determine eutectic solidification mechanisms

    International Nuclear Information System (INIS)

    Nogita, K.; Dahle, A.K.; Drennan, J.

    2002-01-01

    Full text: This study shows the application of electron backscatter diffraction (EBSD) in SEM and convergent beam electron diffraction (CBED) in FEG-TEM to determine eutectic nucleation and growth in hypoeutectic Al-Si foundry alloys. Because the eutectic reaction is often the final stage of solidification it can be expected to have a significant impact on the formation of casting defects, particularly porosity. Previous EBSD work by Nogita and Dahle (2001), Dahle et al (2001), has shown that the eutectic nucleates on the primary phase in the unmodified alloy, and eutectic grains are nucleated in the intergranular liquid, instead of filling the dendrite envelopes, when Sr or Sb is added. However, the orientation relationship between silicon and aluminium in the eutectic has so far not been determined because of difficulties with sample preparation for EBSD and also detection limitations of Kikuchi refraction of silicon and aluminium, particularly in modified alloys with a refined eutectic. The combination of the EBSD technique in SEM and CBED in TEM analyses can provide crystallographic orientation relationships between primary aluminium dendrites, eutectic aluminium and silicon, which are important to explicitly define the solidification mode of the eutectic in hypoeutectic Al-Si alloys. These relationships are influenced, and altered, by the addition of certain elements. This paper also describes the sample preparation techniques for SEM and TEM for samples with different eutectic structures. The advantages the techniques are discussed. Copyright (2002) Australian Society for Electron Microscopy Inc

  16. A developed wedge fixtures assisted high precision TEM samples pre-thinning method: Towards the batch lamella preparation

    Directory of Open Access Journals (Sweden)

    Dandan Wang

    2017-04-01

    Full Text Available Ion milling, wedge cutting or polishing, and focused ion beam (FIB milling are widely-used techniques for the transmission electron microscope (TEM sample preparation. Especially, the FIB milling provides a site-specific analysis, deposition, and ablation of materials in the micrometer and nanometer scale. However, the cost of FIB tools has been always a significant concern. Since it is inevitable to use the FIB technique, the improvement of efficiency is a key point. Traditional TEM sample preparation with FIB was routinely implemented on a single sample each time. Aiming at cost efficiency, a new pre-thinning technique for batch sample preparation was developed in this paper. The present proposal combines the sample preparation techniques with multi-samples thinning, cross-section scanning electron microscopy (SEM, wedge cutting, FIB and other sample pre-thinning techniques. The new pre-thinning technique is to prepare an edge TEM sample on a grinding and polishing fixture with a slant surface. The thickness of the wedges sample can be measured to 1∼2 μm under optical microscope. Therefore, this fixture is superior to the traditional optical method of estimating the membrane thickness. Moreover, by utilizing a multi-sample holding fixture, more samples can be pre-thinned simultaneously, which significantly improved the productivity of TEM sample preparation.

  17. TEM EDS analysis of epitaxially-grown self-assembled indium islands

    Directory of Open Access Journals (Sweden)

    Jasmine Sears

    2017-05-01

    Full Text Available Epitaxially-grown self-assembled indium nanostructures, or islands, show promise as nanoantennas. The elemental composition and internal structure of indium islands grown on gallium arsenide are explored using Transmission Electron Microscopy (TEM Energy Dispersive Spectroscopy (EDS. Several sizes of islands are examined, with larger islands exhibiting high (>94% average indium purity and smaller islands containing inhomogeneous gallium and arsenic contamination. These results enable more accurate predictions of indium nanoantenna behavior as a function of growth parameters.

  18. Advantages and disadvantages of relational and non-relational (NoSQL) databases for analytical tasks

    OpenAIRE

    Klapač, Milan

    2015-01-01

    This work focuses on NoSQL databases, their use for analytical tasks and on comparison of NoSQL databases with relational and OLAP databases. The aim is to analyse the benefits of NoSQL databases and their use for analytical purposes. The first part presents the basic principles of Business Intelligence, Data Warehousing, and Big Data. The second part deals with the key features of relational and NoSQL databases. The last part of the thesis describes the properties of four basic types of NoSQ...

  19. Comparison of Pre-Analytical FFPE Sample Preparation Methods and Their Impact on Massively Parallel Sequencing in Routine Diagnostics

    Science.gov (United States)

    Heydt, Carina; Fassunke, Jana; Künstlinger, Helen; Ihle, Michaela Angelika; König, Katharina; Heukamp, Lukas Carl; Schildhaus, Hans-Ulrich; Odenthal, Margarete; Büttner, Reinhard; Merkelbach-Bruse, Sabine

    2014-01-01

    Over the last years, massively parallel sequencing has rapidly evolved and has now transitioned into molecular pathology routine laboratories. It is an attractive platform for analysing multiple genes at the same time with very little input material. Therefore, the need for high quality DNA obtained from automated DNA extraction systems has increased, especially to those laboratories which are dealing with formalin-fixed paraffin-embedded (FFPE) material and high sample throughput. This study evaluated five automated FFPE DNA extraction systems as well as five DNA quantification systems using the three most common techniques, UV spectrophotometry, fluorescent dye-based quantification and quantitative PCR, on 26 FFPE tissue samples. Additionally, the effects on downstream applications were analysed to find the most suitable pre-analytical methods for massively parallel sequencing in routine diagnostics. The results revealed that the Maxwell 16 from Promega (Mannheim, Germany) seems to be the superior system for DNA extraction from FFPE material. The extracts had a 1.3–24.6-fold higher DNA concentration in comparison to the other extraction systems, a higher quality and were most suitable for downstream applications. The comparison of the five quantification methods showed intermethod variations but all methods could be used to estimate the right amount for PCR amplification and for massively parallel sequencing. Interestingly, the best results in massively parallel sequencing were obtained with a DNA input of 15 ng determined by the NanoDrop 2000c spectrophotometer (Thermo Fisher Scientific, Waltham, MA, USA). No difference could be detected in mutation analysis based on the results of the quantification methods. These findings emphasise, that it is particularly important to choose the most reliable and constant DNA extraction system, especially when using small biopsies and low elution volumes, and that all common DNA quantification techniques can be used for

  20. Comparison of pre-analytical FFPE sample preparation methods and their impact on massively parallel sequencing in routine diagnostics.

    Directory of Open Access Journals (Sweden)

    Carina Heydt

    Full Text Available Over the last years, massively parallel sequencing has rapidly evolved and has now transitioned into molecular pathology routine laboratories. It is an attractive platform for analysing multiple genes at the same time with very little input material. Therefore, the need for high quality DNA obtained from automated DNA extraction systems has increased, especially to those laboratories which are dealing with formalin-fixed paraffin-embedded (FFPE material and high sample throughput. This study evaluated five automated FFPE DNA extraction systems as well as five DNA quantification systems using the three most common techniques, UV spectrophotometry, fluorescent dye-based quantification and quantitative PCR, on 26 FFPE tissue samples. Additionally, the effects on downstream applications were analysed to find the most suitable pre-analytical methods for massively parallel sequencing in routine diagnostics. The results revealed that the Maxwell 16 from Promega (Mannheim, Germany seems to be the superior system for DNA extraction from FFPE material. The extracts had a 1.3-24.6-fold higher DNA concentration in comparison to the other extraction systems, a higher quality and were most suitable for downstream applications. The comparison of the five quantification methods showed intermethod variations but all methods could be used to estimate the right amount for PCR amplification and for massively parallel sequencing. Interestingly, the best results in massively parallel sequencing were obtained with a DNA input of 15 ng determined by the NanoDrop 2000c spectrophotometer (Thermo Fisher Scientific, Waltham, MA, USA. No difference could be detected in mutation analysis based on the results of the quantification methods. These findings emphasise, that it is particularly important to choose the most reliable and constant DNA extraction system, especially when using small biopsies and low elution volumes, and that all common DNA quantification techniques can

  1. Estudo das propriedades psicométricas do Teste de Memória de Reconhecimento – TEM-R

    Directory of Open Access Journals (Sweden)

    Fabián Javier Marín Rueda

    2012-06-01

    Full Text Available The purpose was to verify the psychometric qualities of the Memory Test of Recognition (TEM-R. In a first moment an initial version of the TEM-R was applied at 137 college students. It was found that from the 64 initial items, 15 did not show any frequency response. Based on this it was proceeded a reconfiguration of the instrument, fixing the number of 49 items. It was accomplished a new enforcement where participated 531 college students. The results of the internal structure showed an adequacy to the Rasch model, a absence of bias in the items through the analysis of differential items functioning, and an appropriate factor structure. We observed satisfactory reability indexes. Thus, the TEM-R presented adequate psychometric properties for use in the Brazilian reality.   Keywords: memory; psychological tests; psychometry; validity; reability.

  2. Analytic continuation of quantum Monte Carlo data. Stochastic sampling method

    Energy Technology Data Exchange (ETDEWEB)

    Ghanem, Khaldoon; Koch, Erik [Institute for Advanced Simulation, Forschungszentrum Juelich, 52425 Juelich (Germany)

    2016-07-01

    We apply Bayesian inference to the analytic continuation of quantum Monte Carlo (QMC) data from the imaginary axis to the real axis. Demanding a proper functional Bayesian formulation of any analytic continuation method leads naturally to the stochastic sampling method (StochS) as the Bayesian method with the simplest prior, while it excludes the maximum entropy method and Tikhonov regularization. We present a new efficient algorithm for performing StochS that reduces computational times by orders of magnitude in comparison to earlier StochS methods. We apply the new algorithm to a wide variety of typical test cases: spectral functions and susceptibilities from DMFT and lattice QMC calculations. Results show that StochS performs well and is able to resolve sharp features in the spectrum.

  3. EBSD and TEM Characterization of High Burn-up Mixed Oxide Fuel

    International Nuclear Information System (INIS)

    Teague, Melissa C; Gorman, Brian P.; Miller, Brandon D; King, Jeffrey

    2014-01-01

    Understanding and studying the irradiation behavior of high burn-up oxide fuel is critical to licensing of future fast breeder reactors. Advancements in experimental techniques and equipment are allowing for new insights into previously irradiated samples. In this work dual column focused ion beam (FIB)/scanning electron microscope (SEM) was utilized to prepared transmission electron microscope samples from mixed oxide fuel with a burn-up of 6.7% FIMA. Utilizing the FIB/SEM for preparation resulted in samples with a dose rate of <0.5 mRem/h compared to approximately 1.1 R/h for a traditionally prepared TEM sample. The TEM analysis showed that the sample taken from the cooler rim region of the fuel pellet had approximately 2.5x higher dislocation density than that of the sample taken from the mid-radius due to the lower irradiation temperature of the rim. The dual column FIB/SEM was additionally used to prepared and serially slice approximately 25 um cubes. High quality electron back scatter diffraction (EBSD) were collected from the face at each step, showing, for the first time, the ability to obtain EBSD data from high activity irradiated fuel

  4. TEM investigation of irradiation damage in single crystal CeO2

    International Nuclear Information System (INIS)

    Ye Bei; Kirk, Mark A.; Chen, Weiying; Oaks, Aaron; Rest, Jeffery; Yacout, Abdellatif; Stubbins, James F.

    2011-01-01

    In order to understand the evolution of radiation damage in oxide nuclear fuel, 150-1000 keV Kr ions were implanted into single crystal CeO 2 , as a simulation of fluorite ceramic UO 2 , while in situ transmission electron microscopy (TEM) observations were carried out. Two characteristic defect structures were investigated: dislocation/dislocation loops and nano-size gas bubbles. The growth behavior of defect clusters induced by 1 MeV Kr ions up to doses of 5 x 10 15 ions/cm 2 were followed at 600 deg. C and 800 deg. C. TEM micrographs clearly show the development of defect structures: nucleation of dislocation loops, transformation to extended dislocation lines, and the formation of tangled dislocation networks. The difference in dislocation growth rates at 600 deg. C and 800 deg. C revealed the important role which Ce-vacancies play in the loop formation process. Bubble formation, studied through 150 keV Kr implantations at room temperature and 600 deg. C, might be influenced by either the mobility of metal-vacancies correlated with at threshold temperature or the limitation of gas solubility as a function of temperature.

  5. A Three-Port Topology Comparison for a Low Power Stand-Alone Photovoltaic System

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    Three-port converter (TPC) topologies for renewable energy systems aim to provide higher efficiency and power density than conventional cascaded structures. This work proposes an analytical comparison of different TPC topologies for a photovoltaic LED lamp stand-alone system. A comparison using c...... component stress factor (CSF) is performed, which gives a quantitative measure of the performance of the converter. The candidate topologies are compared to each other according to a defined LED lighting strategy and a solar irradiation profile.......Three-port converter (TPC) topologies for renewable energy systems aim to provide higher efficiency and power density than conventional cascaded structures. This work proposes an analytical comparison of different TPC topologies for a photovoltaic LED lamp stand-alone system. A comparison using...

  6. An alternative to the TEM (Transformed Eulerian Mean) equations

    Science.gov (United States)

    Gaßmann, Almut

    2013-04-01

    The TEM equations constitute a powerful means to get access to the residual circulation. However, due to their foundation on the wave perspective, they deliver only a zonally averaged picture without access to the three-dimensional structure or the local origins of the residual circulation. Therefore it is worth to investigate whether there are alternatives. The pathway followed here is to perform a transformation of the momentum and the potential temperature equation before taking the zonal mean. This is done by removing the steady state ideal wind solution vid = ?×?B-(?±P) from the equations (? - potential temperature, B - Bernoulli function, P - Ertel's potential vorticity EPV, ?± - density). The advantage of that approach is that the total EPV-flux does no longer contain an explicitly visible 'do-nothing-flux'. This flux, ?? ×?B, does only vanish when averaging on isentropic surfaces, but not on other isosurfaces. Here we find the reason why the conventional zonal mean on isentropes delivers a direct overturning cell on each hemisphere, whereas on other isosurfaces we obtain the typical three-cell structure with Headley, Ferrel, and polar cells. It will be demonstrated and made visible through idealized climate experiments with the ICON-IAP model that the zonal averages of the nonideal wind components vnid = v - vid and wnid = w - wid constitute similar direct overturning cells on non-isentropic surfaces as obtained with the TEM-generated v* and w*. It is also interesting to inspect fields of local nonideal wind components, the very origin of the residual circulation.

  7. A Comparison of Two Approaches for the Ruggedness Testing of an Analytical Method

    International Nuclear Information System (INIS)

    Maestroni, Britt

    2016-01-01

    As part of an initiative under the “Red Analitica de Latino America y el Caribe” (RALACA) network the FAO/IAEA Food and Environmental Protection Laboratory validated a multi-residue method for pesticides in potato. One of the parameters to be assessed was the intra laboratory robustness or ruggedness. The objective of this work was to implement a worked example for RALACA laboratories to test for the robustness (ruggedness) of an analytical method. As a conclusion to this study, it is evident that there is a need for harmonization of the definition of the terms robustness/ruggedness, the limits, the methodology and the statistical treatment of the generated data. A worked example for RALACA laboratories to test for the robustness (ruggedness) of an analytical method will soon be posted on the RALACA website (www.red-ralaca.net). This study was carried out with collaborators from LVA (Austria), University of Antwerp (Belgium), University of Leuwen (The Netherlands), Universidad de la Republica (Uruguay) and Agilent technologies.

  8. TEM microstructural analysis of creep deformed CM186LC single crystal Ni-base superalloy

    Energy Technology Data Exchange (ETDEWEB)

    Dubiel, B.; Czyrska-Filemonowicz, A. [AGH Univ. of Science and Technology, Krakow (Poland); Blackler, M. [Howmet Ltd., Exeter (United Kingdom); Barnard, P.M. [ALSTOM Power Turbo-Systems Technology Centre, Rugby (United Kingdom)

    2006-07-01

    The nickel based single crystal superalloy CM186LC was extensively investigated as a potential low cost material for industrial gas turbine vanes within the COST522 programme. The alloy exhibits inhomogeneous structure consisting of dendritic regions and eutectic colonies. In the present work attention is focused on microstructural changes observed in single crystal CM186LC following creep deformation at 750 C. Creep tests were conducted at 750 C with an applied stress of 560 or 675 MPa for up to 11440 hours. The microstructure o ruptured and terminated specimens was investigated by scanning (SEM) and transmission (TEM) electron microscopy. TEM analysis revealed the microstructural changes in the CM186LC at primary and secondary creep as well as after creep rupture. (orig.)

  9. TEM observations of HT-9 as-welded weldment microstructures

    International Nuclear Information System (INIS)

    Foulds, J.R.; Lechtenberg, T.A.

    1984-01-01

    TEM studies of different locations in an HT-9 weldment indicated delta-ferrite (delta) occurrence, M 23 C 6 precipitation at delta-martensite interfaces, fine carbide precipitation at prior austenite grain boundaries, and martensite lath and lath packet size to be the distinguishable microstructure features observed. Furthermore, retained austenite films were observed in the weld metal and the HAZ adjacent to the weld metal that reached the highest temperature during joining. The microstructures correlate well with the observed room temperature microhardness except for the fusion boundary in weld metal which exhibited a hardness drop and an unexpected minimum amount of delta-ferrite

  10. In Situ TEM Multi-Beam Ion Irradiation as a Technique for Elucidating Synergistic Radiation Effects

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Caitlin; Bufford, Daniel; Muntifering, Brittany; Senor, David; Steckbeck, Mackenzie; Davis, Justin; Doyle, Barney; Buller, Daniel; Hattar, Khalid

    2017-09-29

    Materials designed for nuclear reactors undergo microstructural changes resulting from a combination of several environmental factors, including neutron irradiation damage, gas accumulation and elevated temperatures. Typical ion beam irradiation experiments designed for simulating a neutron irradiation environment involve irradiating the sample with a single ion beam and subsequent characterization of the resulting microstructure, often by transmission electron microscopy (TEM). This method does not allow for examination of microstructural effects due to simultaneous gas accumulation and displacement cascade damage, which occurs in a reactor. Sandia’s in situ ion irradiation TEM (I3TEM) offers the unique ability to observe microstructural changes due to irradiation damage caused by concurrent multi-beam ion irradiation in real time. This allows for time-dependent microstructure analysis. A plethora of additional in situ stages can be coupled with these experiments, e.g., for more accurately simulating defect kinetics at elevated reactor temperatures. This work outlines experiments showing synergistic effects in Au using in situ ion irradiation with various combinations of helium, deuterium and Au ions, as well as some initial work on materials utilized in tritium-producing burnable absorber rods (TPBARs): zirconium alloys and LiAlO2.

  11. In Situ TEM Multi-Beam Ion Irradiation as a Technique for Elucidating Synergistic Radiation Effects

    Directory of Open Access Journals (Sweden)

    Caitlin Anne Taylor

    2017-09-01

    Full Text Available Materials designed for nuclear reactors undergo microstructural changes resulting from a combination of several environmental factors, including neutron irradiation damage, gas accumulation and elevated temperatures. Typical ion beam irradiation experiments designed for simulating a neutron irradiation environment involve irradiating the sample with a single ion beam and subsequent characterization of the resulting microstructure, often by transmission electron microscopy (TEM. This method does not allow for examination of microstructural effects due to simultaneous gas accumulation and displacement cascade damage, which occurs in a reactor. Sandia’s in situ ion irradiation TEM (I3TEM offers the unique ability to observe microstructural changes due to irradiation damage caused by concurrent multi-beam ion irradiation in real time. This allows for time-dependent microstructure analysis. A plethora of additional in situ stages can be coupled with these experiments, e.g., for more accurately simulating defect kinetics at elevated reactor temperatures. This work outlines experiments showing synergistic effects in Au using in situ ion irradiation with various combinations of helium, deuterium and Au ions, as well as some initial work on materials utilized in tritium-producing burnable absorber rods (TPBARs: zirconium alloys and LiAlO2.

  12. A TEM quantitative evaluation of strengthening in an Mg-RE alloy reinforced with SiC

    International Nuclear Information System (INIS)

    Cabibbo, Marcello; Spigarelli, Stefano

    2011-01-01

    Magnesium alloys containing rare earth elements are known to have high specific strength, good creep and corrosion resistance up to 523 K. The addition of SiC ceramic particles strengthens the metal matrix composite resulting in better wear and creep resistance while maintaining good machinability. The role of the reinforcement particles in enhancing strength can be quantitatively evaluated using transmission electron microscopy (TEM). This paper presents a quantitative evaluation of the different strengthening contributions, determined through TEM inspections, in an SiC Mg-RE composite alloy containing yttrium, neodymium, gadolinium and dysprosium. Compression tests at temperatures ranging between 290 and 573 K were carried out. The microstructure strengthening mechanism was studied for all the compression conditions. Strengthening was compared to the mechanical results and the way the different contributions were combined is also discussed and justified. - Research Highlights: → TEM yield strengthening terms evaluation on a Mg-RE SiC alloy. → The evaluation has been extended to different compression temperature conditions. → Linear and Quadratic sum has been proposed and validated. → Hall-Petch was found to be the most prominent strengthening contributions.

  13. In situ TEM observation of the growth and decomposition of monoclinic W18O49 nanowires

    International Nuclear Information System (INIS)

    Chen, C L; Mori, H

    2009-01-01

    The growth of monoclinic W 18 O 49 nanowires by heat treatment of a tungsten filament at ∼873 K and the decomposition of these nanowires under 200 keV electron irradiation at ∼1023 K have been investigated using in situ transmission electron microscopy (TEM). In situ TEM observation of the growth confirmed the vapor-solid growth mechanism of the monoclinic W 18 O 49 nanowires. In situ irradiation experiments revealed the formation of metallic bcc tungsten from monoclinic W 18 O 49 nanowires under 200 keV electron irradiation.

  14. Combined RBS and TEM characterization of nano-SiGe layers embedded in SiO2

    International Nuclear Information System (INIS)

    Kling, A.; Ortiz, M.I.; Sangrador, J.; Rodriguez, A.; Rodriguez, T.; Ballesteros, C.; Soares, J.C.

    2006-01-01

    Grazing incidence RBS has been tested as a technique to detect and characterize SiGe nanoparticles embedded in a SiO 2 matrix. Suitable structures were deposited by low pressure chemical vapour deposition and characterized by TEM and RBS. The layers containing nanoparticles have been modelled by stacks of sublayers consisting of SiGeO layers with compositions calculated according to presumed shapes, sizes, Si/Ge ratios and particle area densities and used as input for RUMP. The nanoparticle parameters obtained by fitting the experimental RBS spectra agree well with the findings by TEM. This demonstrates that RBS is a useful and fast technique to characterize this kind of structures

  15. A semi-analytical computation of the theoretical uncertainties of the solar neutrino flux

    DEFF Research Database (Denmark)

    Jorgensen, Andreas C. S.; Christensen-Dalsgaard, Jorgen

    2017-01-01

    We present a comparison between Monte Carlo simulations and a semi-analytical approach that reproduces the theoretical probability distribution functions of the solar neutrino fluxes, stemming from the pp, pep, hep, Be-7, B-8, N-13, O-15 and F-17 source reactions. We obtain good agreement between...

  16. Analytical electron microscopy of Mg-SiO smokes - A comparison with infrared and XRD studies

    Science.gov (United States)

    Rietmeijer, F. J. M.; Nuth, J. A.; Mackinnon, I. D. R.

    1986-01-01

    Analytical electron microscopy conducted for Mg-SiO smokes (experimentally obtained from samples previously characterized by IR spectroscopy) indicates that the microcrystallinity content of unannealed smokes increases with increased annealing for up to 30 hr. The growth of forsterite microcrystallites in the initially nonstoichiometric smokes may give rise to the contemporaneous growth of the SiO polymorph tridymite and MgO; after 4 hr of annealing, these react to form enstatite. It is suggested that XRD analysis and IR spectroscopy should be conducted in conjunction with detailed analytical electron microscopy for the detection of emerging crystallinity in vapor-phase condensates.

  17. Analytical prediction of digital signal crosstalk of FCC

    Science.gov (United States)

    Belleisle, A. P.

    1972-01-01

    The results are presented of study effort whose aim was the development of accurate means of analyzing and predicting signal cross-talk in multi-wire digital data cables. A complete analytical model is developed n + 1 wire systems of uniform transmission lines with arbitrary linear boundary conditions. In addition, a minimum set of parameter measurements required for the application of the model are presented. Comparisons between cross-talk predicted by this model and actual measured cross-talk are shown for a six conductor ribbon cable.

  18. Analytical chemistry instrumentation

    International Nuclear Information System (INIS)

    Laing, W.R.

    1986-01-01

    In nine sections, 48 chapters cover 1) analytical chemistry and the environment 2) environmental radiochemistry 3) automated instrumentation 4) advances in analytical mass spectrometry 5) fourier transform spectroscopy 6) analytical chemistry of plutonium 7) nuclear analytical chemistry 8) chemometrics and 9) nuclear fuel technology

  19. Coupling impedance of an in-vacuum undulator: Measurement, simulation, and analytical estimation

    Directory of Open Access Journals (Sweden)

    Victor Smaluk

    2014-07-01

    Full Text Available One of the important issues of the in-vacuum undulator design is the coupling impedance of the vacuum chamber, which includes tapered transitions with variable gap size. To get complete and reliable information on the impedance, analytical estimate, numerical simulations and beam-based measurements have been performed at Diamond Light Source, a forthcoming upgrade of which includes introducing additional insertion device (ID straights. The impedance of an already existing ID vessel geometrically similar to the new one has been measured using the orbit bump method. The measurement results in comparison with analytical estimations and numerical simulations are discussed in this paper.

  20. Analytic method study of point-reactor kinetic equation when cold start-up

    International Nuclear Information System (INIS)

    Zhang Fan; Chen Wenzhen; Gui Xuewen

    2008-01-01

    The reactor cold start-up is a process of inserting reactivity by lifting control rod discontinuously. Inserting too much reactivity will cause short-period and may cause an overpressure accident in the primary loop. It is therefore very important to understand the rule of neutron density variation and to find out the relationships among the speed of lifting control rod, and the duration and speed of neutron density response. It is also helpful for the operators to grasp the rule in order to avoid a start-up accident. This paper starts with one-group delayed neutron point-reactor kinetics equations and provides their analytic solution when reactivity is introduced by lifting control rods discontinuously. The analytic expression is validated by comparison with practical data. It is shown that the analytic solution agrees well with numerical solution. Using this analytical solution, the relationships among neutron density response with the speed of lifting control rod and its duration are also studied. By comparing the results with those under the condition of step inserted reactivity, useful conclusions are drawn

  1. Comprehensive analysis of TEM methods for LiFePO4/FePO4 phase mapping: spectroscopic techniques (EFTEM, STEM-EELS) and STEM diffraction techniques (ACOM-TEM)

    DEFF Research Database (Denmark)

    Mu, X.; Kobler, A.; Wang, D.

    2016-01-01

    Transmission electron microscopy (TEM) has been used intensively in investigating battery materials, e.g. to obtain phase maps of partially (dis)charged (lithium) iron phosphate (LFP/FP), which is one of the most promising cathode material for next generation lithium ion (Li-ion) batteries. Due t...

  2. Differential dependence on N-glycosylation of anthrax toxin receptors CMG2 and TEM8.

    Directory of Open Access Journals (Sweden)

    Sarah Friebe

    Full Text Available ANTXR 1 and 2, also known as TEM8 and CMG2, are two type I membrane proteins, which have been extensively studied for their role as anthrax toxin receptors, but with a still elusive physiological function. Here we have analyzed the importance of N-glycosylation on folding, trafficking and ligand binding of these closely related proteins. We find that TEM8 has a stringent dependence on N-glycosylation. The presence of at least one glycan on each of its two extracellular domains, the vWA and Ig-like domains, is indeed necessary for efficient trafficking to the cell surface. In the absence of any N-linked glycans, TEM8 fails to fold correctly and is recognized by the ER quality control machinery. Expression of N-glycosylation mutants reveals that CMG2 is less vulnerable to sugar loss. The absence of N-linked glycans in one of the extracellular domains indeed has little impact on folding, trafficking or receptor function of the wild type protein expressed in tissue culture cells. N-glycans do, however, seem required in primary fibroblasts from human patients. Here, the presence of N-linked sugars increases the tolerance to mutations in cmg2 causing the rare genetic disease Hyaline Fibromatosis Syndrome. It thus appears that CMG2 glycosylation provides a buffer towards genetic variation by promoting folding of the protein in the ER lumen.

  3. Theoretical analysis and modeling of Thickness-Expansion Mode (TEM) sensors for fluid characterization.

    Science.gov (United States)

    Elvira, Luis; Resa, Pablo; Castro, Pedro

    2013-03-01

    In this paper, the principles of Thickness-Expansion Mode (TEM) resonators for the characterization of fluids are described. From the measurement of the resonance parameters of a TEM piezoelectric transducer, the compressional acoustic impedance of gases and liquids can be determined. Since the propagation of mechanical waves into the fluid is not necessary, information in a wide range of frequencies can be obtained. Alternatively, these sensors can be driven in combination with other ultrasonic techniques to simultaneously determine the density, speed of sound and viscosity of samples. Some potential applications include the probe monitoring of processes and the characterization of fluids under harsh conditions. The main experimental criteria for the design and construction of high-resolution impedance meters (such as piezoelectric material, protective coating or thermal response) have been studied using equivalent electrical circuit modeling and finite element analysis. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Study of comparison between neutron activation analysis and the other analytical methods

    International Nuclear Information System (INIS)

    Nagatsuka, Sumiko

    1986-01-01

    The neutron activation analysis (NAA) is compared with other analytical methods based on various data. It is concluded that NAA is most frequently used for the analysis of NBS environmental standard samples. NAA is suitable for the analysis of trace elements contained in environmental samples since non-destructive quantitative determination can be carried out simultaneously for different elements. NAA and XRF are the only methods which can be used for analyzing oil samples. This also indicates the usefulness of non-destructive techniques. In any standard sample, NAA can achieve a high accuracy for more than 90 % of the elements contained. On the other hand, the accuracy varies depending on the type of sample in the case of the other analytical methods examined. Regarding the prescision, NAA for any standard sample is the smallest in the proportion of the number of elements determined with C.V. (coefficient of variation) of less than 10 % to the total number of elements contained. However, the total number of elements which can be determined by NAA with C.V. of less than 10 % is greater than that by any of the other four methods examined. It should be noticed that there are some elements which can be determined only by NAA. (Nogami, K.)

  5. Stable TEM00-mode Nd:YAG solar laser operation by a twisted fused silica light-guide

    Science.gov (United States)

    Bouadjemine, R.; Liang, D.; Almeida, J.; Mehellou, S.; Vistas, C. R.; Kellou, A.; Guillot, E.

    2017-12-01

    To improve the output beam stability of a TEM00-mode solar-pumped laser, a twisted fused silica light-guide was used to achieve uniform pumping along a 3 mm diameter and 50 mm length Nd:YAG rod. The concentrated solar power at the focal spot of a primary parabolic mirror with 1.18 m2 effective collection area was efficiently coupled to the entrance aperture of a 2D-CPC/2V-shaped pump cavity, within which the thin laser rod was pumped. Optimum solar laser design parameters were found through ZEMAX© non-sequential ray-tracing and LASCAD© laser cavity analysis codes. 2.3 W continuous-wave TEM00-mode 1064 nm laser power was measured, corresponding to 1.96 W/m2 collection efficiency and 2.2 W laser beam brightness figure of merit. Excellent TEM00-mode laser beam profile at M2 ≤ 1.05 and very good output power stability of less than 1.6% were achieved. Heliostat orientation error dependent laser power variation was considerably less than previous solar laser pumping schemes.

  6. TEM characterization of corrosion products formed on a SS-15ZR alloy

    International Nuclear Information System (INIS)

    Luo, J. S.; Abraham, D. P.

    2000-01-01

    The corrosion products formed on a stainless steel-15Zr (SS-15Zr) alloy have been characterized by transmission electron microscopy (TEM) and energy dispersive x-ray spectroscopy (EDS). Examination of alloy particles that were immersed in 90 C deionized water for two years revealed that different corrosion products were formed on the stainless steel and intermetallic phases. Two corrosion products were identified on an austenite particle: trevorite (NiFe 2 O 4 ) in the layer close to the metal and maghemite (Fe 2 O 3 ) in the outer layer. The corrosion layer formed on the intermetallic was uniform, adherent, and amorphous. The EDS analysis indicated that the layer was enriched in zirconium when compared with the intermetallic composition. High-resolution TEM images of the intermetallic-corrosion layer interface show an interlocking metal-oxide interface which may explain the relatively strong adherence of the corrosion layer to the intermetallic surface. These results will be used to evaluate corrosion mechanisms and predict long-term corrosion behavior of the alloy waste form

  7. Edge-melting: nanoscale key-mechanism to explain nanoparticle formation from heated TEM grids

    Energy Technology Data Exchange (ETDEWEB)

    Cesaria, Maura, E-mail: maura.cesaria@le.infn.it [Department of Mathematics and Physics “E. De Giorgi”, University of Salento, Via Arnesano, 73100 Lecce (Italy); Taurino, Antonietta; Catalano, Massimo [Institute for Microelectronics and Microsystems, IMM-CNR, Via Monteroni, 73100 Lecce (Italy); Caricato, Anna Paola; Martino, Maurizio [Department of Mathematics and Physics “E. De Giorgi”, University of Salento, Via Arnesano, 73100 Lecce (Italy)

    2016-03-01

    Graphical abstract: - Highlights: • Nanoparticle formation from metal grids explained by edge melting as key mechanism. • The inconsistency of bulk phenomenology invoking the vapor pressure is discussed. • Surface-melting and size-dependent evaporation are questioned as unsatisfactory. • Edge-melting: edges, corners, facets invoked as highly thermally unstable surfaces. • The polycrystalline nature of the really occurring metal grids is accounted for. - Abstract: In this study, we examine at both experimental and fundamental levels, the experimental evidence of nanoparticle formation in transmission electron microscopy (TEM) metal grids annealed at temperatures lower than the melting point of the corresponding metal bulk material. Our experimental investigation considers the most thermally unstable TEM grids (i.e. Cu-grids) and inspects the possible sources and mechanisms of contamination of thin films, conventionally deposited on carbon-coated Cu-grids. The investigations are supported by morphological–compositional analyses performed in different regions of the TEM sample. Then, a general model is formulated and discussed in order to explain the grid thermal instability, based on the critical role of edge-melting (i.e. melting initiated at edges and corners of the grid bars), the enhanced rate of evaporation from a liquid surface and the polycristallinity of the grid bars. Hence, we totally disregard conventional arguments such as bulk evaporation and metal vapor pressure and, in order to emphasize and clarify the alternative point of view of our model, we also overview the nano-scale melting phenomenology relevant to our discussion and survey the discrepancies reported in the literature.

  8. Structural and morphological TEM characterization of GaAs based nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Soda, Marcello

    2012-02-03

    The question of a structural and morphological characterization of GaAs based nanowires is the research interest of this thesis. For this purpose standard and analytical transmission electron microscopy techniques were employed. New investigation methodologies are introduced in order to obtain a reliable interpretation of the results. The principal motivation on developing a new investigation method is the necessity to relate the results of crystal structure and morphology characterizations to microscopic and NW-specific parameters and not to macroscopic and general growth parameters. This allows a reliable comparison of NW characteristics and enhances the comprehension of their growth mechanism.The analysis of the results on crystal structure investigations, assuming this new perspective, delivers the fundamental finding that the axial growth of Au-assisted GaAs NWs can change in a pseudo Ga-assisted growth due to a non steady-state regime of the Ga accumulation process in the liquid droplet. The attempt to associate the observed crystal structures to one of these two growth modes reveals that zinc blende segments are most probably generated when a pseudo Ga-assisted growth occurs. This experimental evidence is in accordance with investigations developed by Glas et al. and Spirkoska et al. and with the current understanding of the NW growth mechanism and unifies the interpretation of catalytic growth of GaAs NWs. A Mn doped GaAs shell deposited at low temperature on core GaAs NWs is characterized for the first time. The growth is found to be epitaxial and to confer the quality of the core crystal to the shell crystal. As a consequence a high stacking fault density of the core NW limits the temperature of the shell growth due to the formation of clusters. Cross sections of (Ga,Mn)As shells are investigated. Simple kinetic and thermodynamical considerations lead to the conclusion of morphological instability of the low temperature radial growth. Analytical

  9. Multi-analytical Approaches Informing the Risk of Sepsis

    Science.gov (United States)

    Gwadry-Sridhar, Femida; Lewden, Benoit; Mequanint, Selam; Bauer, Michael

    Sepsis is a significant cause of mortality and morbidity and is often associated with increased hospital resource utilization, prolonged intensive care unit (ICU) and hospital stay. The economic burden associated with sepsis is huge. With advances in medicine, there are now aggressive goal oriented treatments that can be used to help these patients. If we were able to predict which patients may be at risk for sepsis we could start treatment early and potentially reduce the risk of mortality and morbidity. Analytic methods currently used in clinical research to determine the risk of a patient developing sepsis may be further enhanced by using multi-modal analytic methods that together could be used to provide greater precision. Researchers commonly use univariate and multivariate regressions to develop predictive models. We hypothesized that such models could be enhanced by using multiple analytic methods that together could be used to provide greater insight. In this paper, we analyze data about patients with and without sepsis using a decision tree approach and a cluster analysis approach. A comparison with a regression approach shows strong similarity among variables identified, though not an exact match. We compare the variables identified by the different approaches and draw conclusions about the respective predictive capabilities,while considering their clinical significance.

  10. Comparison of Three Analytical Methods for Separation of Mineral and Chelated Fraction from an Adulterated Zn-EDTA Fertilizer

    International Nuclear Information System (INIS)

    Khan, M.S.; Qazi, M.A.; Khan, N.A.; Mian, S.M.; Ahmed, N.; Ahmed, N.

    2013-01-01

    Summary: Different analytical procedures are being employed in the world to quantify the chelated portion in a Zn-EDTA fertilizer. Agriculture Department, Government of the Punjab is following Shahid's analytical method in this regard. This method is based on Ion-chromatography (IC) that separates the mineral zinc (Zn) from an adulterated Zn-EDTA fertilizer sample i.e. mixture of mineral and chelated Zn fractions. To find out its effectiveness and suitability, this comparative study was carried out by analyzing adulterated, non-adulterated Zn-EDTA standard and Zn-EDTA samples taken from market in thrice following three methods namely Shahid's (IC) analytical method, Atomic Absorption Spectrophotometric (AAS) method based on the principle of precipitating the mineral Zn fraction at high pH value by using alkali solution of suitable concentration and analysis of filtrate containing only chelated fraction and Association of Official Analytical Chemists (AOAC) method FM-841 respectively. Adulterated Zn-EDTA samples were prepared by mixing of known quantity of mineral Zn with chelated Zn-EDTA standard. The results showed that Shahid's analytical method and AAS method, both successfully estimated the chelated fraction. The AOAC FM-841 method was insensitive to put a ceiling on the mineral fraction hence did not furnish the reliable results. The Shahid's analytical method was selected being equallyeffective to produce reliable results both for solid and liquid Zn-EDTA samples. The AAS method was comparable in only liquid samples. (author)

  11. Analytical and experimental vibration analysis of BWR pressure vessel internals

    International Nuclear Information System (INIS)

    Krutzik, N.; Schad, O.

    1975-01-01

    This report attempts to evaluate the validity as well as quality of several analytical methods in the light of presently available experimental data for the internals of pressure vessels of boiling-water-reactor-types. The experimental checks were performed after the numerical analysis was completed and showed the accuracy of the numerical results. The analytical investigations were done by finite element programmes - 2-dimensional as well as 3-dimensional, where the effect of the mass distribution with parts of virtual masses on the dynamic response could be studied in depth. The experimental data were collected at various different plants and with different mass correlations. Besides evaluating the dynamic characteristics of the components, tests were also performed to evaluate the vibrations of the pressure vessel relative to the main structure. After analysing extensive recorded data much better understanding of the response under a variety of loading- and boundary conditions could be gained. The comparison of the results of analytical studies with the experimental results made a broad qualitative evaluation possible. (Auth.)

  12. Analytical and Numerical Evaluation of Limit States of MSE Wall Structure

    Directory of Open Access Journals (Sweden)

    Drusa Marián

    2016-12-01

    Full Text Available Simplification of the design of Mechanically Stabilized Earth wall structures (MSE wall or MSEW is now an important factor that helps us not only to save a time and costs, but also to achieve the desired results more reliably. It is quite common way in practice, that the designer of a section of motorway or railway line gives order for design to a supplier of geosynthetics materials. However, supplier company has experience and skills, but a general designer does not review the safety level of design and its efficiency, and is simply incorporating into the overall design of the construction project. Actually, large number of analytical computational methods for analysis and design of MSE walls or similar structures are known. The problem of these analytical methods is the verification of deformations and global stability of structure. The article aims to clarify two methods of calculating the internal stability of MSE wall and their comparison with FEM numerical model. Comparison of design approaches allows us to draft an effective retaining wall and tells us about the appropriateness of using a reinforcing element.

  13. Let's Talk... Analytics

    Science.gov (United States)

    Oblinger, Diana G.

    2012-01-01

    Talk about analytics seems to be everywhere. Everyone is talking about analytics. Yet even with all the talk, many in higher education have questions about--and objections to--using analytics in colleges and universities. In this article, the author explores the use of analytics in, and all around, higher education. (Contains 1 note.)

  14. Optical, mechanical and TEM assessment of titania-doped Bi2V1 ...

    Indian Academy of Sciences (India)

    2016-08-26

    Aug 26, 2016 ... Home; Journals; Bulletin of Materials Science; Volume 37; Issue 7. Optical, mechanical and TEM assessment of titania-doped Bi2V1−TiO5.5−δ bismuth vanadate oxides. Gurbinder Kaur Gary Pickrell Vishal Kumar Om Prakash Pandey Kulvir Singh Daniel Homa. Volume 37 Issue 7 December 2014 pp ...

  15. Analytics for Education

    Science.gov (United States)

    MacNeill, Sheila; Campbell, Lorna M.; Hawksey, Martin

    2014-01-01

    This article presents an overview of the development and use of analytics in the context of education. Using Buckingham Shum's three levels of analytics, the authors present a critical analysis of current developments in the domain of learning analytics, and contrast the potential value of analytics research and development with real world…

  16. Does leaf chemistry differentially affect breakdown in tropical vs temperate streams? Importance of standardized analytical techniques to measure leaf chemistry

    Science.gov (United States)

    Marcelo Ard& #243; n; Catherine M. Pringle; Susan L. Eggert

    2009-01-01

    Comparisons of the effects of leaf litter chemistry on leaf breakdown rates in tropical vs temperate streams are hindered by incompatibility among studies and across sites of analytical methods used to measure leaf chemistry. We used standardized analytical techniques to measure chemistry and breakdown rate of leaves from common riparian tree species at 2 sites, 1...

  17. The Journal of Learning Analytics: Supporting and Promoting Learning Analytics Research

    OpenAIRE

    Siemens, George

    2014-01-01

    The paper gives a brief overview of the main activities for the development of the emerging field of learning analytics led by the Society for Learning Analytics Research (SoLAR). The place of the Journal of Learning Analytics is identified Analytics is the most significant new initiative of SoLAR. 

  18. The "Journal of Learning Analytics": Supporting and Promoting Learning Analytics Research

    Science.gov (United States)

    Siemens, George

    2014-01-01

    The paper gives a brief overview of the main activities for the development of the emerging field of learning analytics led by the Society for Learning Analytics Research (SoLAR). The place of the "Journal of Learning Analytics" is identified. Analytics is the most significant new initiative of SoLAR.

  19. An analytical approximation for the prediction of transients with temperature feedback

    Energy Technology Data Exchange (ETDEWEB)

    Palma, Daniel A.P. [Instituto Federal do Rio de Janeiro (IFRJ), RJ (Brazil); Martinez, Aquilino S. [COPPE/UFRJ, RJ (Brazil). Programa de Engenharia Nuclear

    2010-05-15

    In the present paper a new analytical solution for the point kinetics equation system with temperature feedback is presented. This solution is based on the expansion of the neutron density in terms of the generation time of prompt neutrons (Nahla, 2009) and presents the advantage of being explicit in time and having a simple functional form in comparison with other existing formulations in supercritical transients. (orig.)

  20. An analytical approximation for the prediction of transients with temperature feedback

    International Nuclear Information System (INIS)

    Palma, Daniel A.P.; Martinez, Aquilino S.

    2010-01-01

    In the present paper a new analytical solution for the point kinetics equation system with temperature feedback is presented. This solution is based on the expansion of the neutron density in terms of the generation time of prompt neutrons (Nahla, 2009) and presents the advantage of being explicit in time and having a simple functional form in comparison with other existing formulations in supercritical transients. (orig.)

  1. Suspended DNA structural characterization by TEM diffraction

    KAUST Repository

    Marini, Monica

    2017-12-01

    In this work, micro-fabrication, super-hydrophobic properties and a physiologically compatible preparation step are combined and tailored to obtain background free biological samples to be investigated by Transmission Electron Microscopy (TEM) diffraction technique. The validation was performed evaluating a well-known parameter such as the DNA interbases value. The diffraction spacing measured is in good agreement with those obtained by HRTEM direct metrology and by traditional X-Ray diffraction. This approach addresses single molecule studies in a simplified and reproducible straightforward way with respect to more conventional and widely used techniques. In addition, it overcomes the need of long and elaborated samples preparations: the sample is in its physiological environment and the HRTEM data acquisition occurs without any background interference, coating, staining or additional manipulation. The congruence in the results reported in this paper makes the application of this approach extremely promising towards those molecules for which crystallization remains a hurdle, such as cell membrane proteins and fibrillar proteins.

  2. Suspended DNA structural characterization by TEM diffraction

    KAUST Repository

    Marini, Monica; Allione, Marco; Lopatin, Sergei; Moretti, Manola; Giugni, Andrea; Torre, Bruno; Di Fabrizio, Enzo M.

    2017-01-01

    In this work, micro-fabrication, super-hydrophobic properties and a physiologically compatible preparation step are combined and tailored to obtain background free biological samples to be investigated by Transmission Electron Microscopy (TEM) diffraction technique. The validation was performed evaluating a well-known parameter such as the DNA interbases value. The diffraction spacing measured is in good agreement with those obtained by HRTEM direct metrology and by traditional X-Ray diffraction. This approach addresses single molecule studies in a simplified and reproducible straightforward way with respect to more conventional and widely used techniques. In addition, it overcomes the need of long and elaborated samples preparations: the sample is in its physiological environment and the HRTEM data acquisition occurs without any background interference, coating, staining or additional manipulation. The congruence in the results reported in this paper makes the application of this approach extremely promising towards those molecules for which crystallization remains a hurdle, such as cell membrane proteins and fibrillar proteins.

  3. TEM10 homodyne detection as an optimal small-displacement and tilt-measurement scheme

    DEFF Research Database (Denmark)

    Delaubert, Vincent; Treps, Nikolas; Lassen, Mikael Østergaard

    2006-01-01

    We report an experimental demonstration of optimal measurements of small displacement and tilt of a Gaussian beam - two conjugate variables - involving a homodyne detection with a TEM10 local oscillator. We verify that the standard split detection is only 64% efficient. We also show a displacement...

  4. Fault detection by Turam TEM survey. Numerical model studies and a case history; TEM ho Turam sokutei haichi ni yoru danso kenshutsu no kokoromi. Model keisan to jisshirei

    Energy Technology Data Exchange (ETDEWEB)

    Wada, K; Tsutsui, T [Mitsui Mineral Development Engineering Co. Ltd., Tokyo (Japan); Ito, T [Chiba Univ., Chiba (Japan). Faculty of Science; Takeuchi, A [Toyama University, Toyama (Japan). Faculty of Science; He, P [Power Reactor and Nuclear fuel Development Corp., Tokyo (Japan)

    1997-05-27

    With an objective to detect faults estimated to exist along the Shigesumi valley in the Kamioka mine, discussions were given by using electromagnetic survey, which uses the Turam measurement arrangement based on the TEM method, and three-dimensional model calculations. The Turam measurement arrangement, which installs transmission loop fixedly, is used to identify nature and distribution of electrically conductive objects upon noticing abnormal portions in magnetic fields in the measurement data. In the model calculation, the plate model calculation method and the FDTD method were used, and so was the calculation code TEM3DL. The result revealed that strong topographical influence is seen from steep V-shaped valley existing along the traverse line in the measurement data, but an abnormal resistivity band accompanying remarkable distortion in the curve was detected. According to the result of the model calculation, anomaly detection may be found difficult in locations where a low resistivity band has not grown enough locally. It was possible from these facts to assume a model in which the low resistivity band exists directly below the Shigesumi valley, suggesting existence of faults. 2 refs., 8 figs.

  5. Dynamics of electrochemical lithiation/delithiation of graphene-encapsulated silicon nanoparticles studied by in-situ TEM.

    Science.gov (United States)

    Luo, Langli; Wu, Jinsong; Luo, Jiayan; Huang, Jiaxing; Dravid, Vinayak P

    2014-01-24

    The incorporation of nanostructured carbon has been recently reported as an effective approach to improve the cycling stability when Si is used as high-capacity anodes for the next generation Li-ion battery. However, the mechanism of such notable improvement remains unclear. Herein, we report in-situ transmission electron microscopy (TEM) studies to directly observe the dynamic electrochemical lithiation/delithiation processes of crumpled graphene-encapsulated Si nanoparticles to understand their physical and chemical transformations. Unexpectedly, in the first lithiation process, crystalline Si nanoparticles undergo an isotropic to anisotropic transition, which is not observed in pure crystalline and amorphous Si nanoparticles. Such a surprising phenomenon arises from the uniformly distributed localized voltage around the Si nanoparticles due to the highly conductive graphene sheets. It is observed that the intimate contact between graphene and Si is maintained during volume expansion/contraction. Electrochemical sintering process where small Si nanoparticles react and merge together to form large agglomerates following spikes in localized electric current is another problem for batteries. In-situ TEM shows that graphene sheets help maintain the capacity even in the course of electrochemical sintering. Such in-situ TEM observations provide valuable phenomenological insights into electrochemical phenomena, which may help optimize the configuration for further improved performance.

  6. TEM Study of High-Temperature Precipitation of Delta Phase in Inconel 718 Alloy

    Directory of Open Access Journals (Sweden)

    Moukrane Dehmas

    2011-01-01

    Full Text Available Inconel 718 is widely used because of its ability to retain strength at up to 650∘C for long periods of time through coherent metastable  Ni3Nb precipitation associated with a smaller volume fraction of  Ni3Al precipitates. At very long ageing times at service temperature,  decomposes to the stable Ni3Nb phase. This latter phase is also present above the  solvus and is used for grain control during forging of alloy 718. While most works available on precipitation have been performed at temperatures below the  solvus, it appeared of interest to also investigate the case where phase precipitates directly from the fcc matrix free of  precipitates. This was studied by X-ray diffraction and transmission electron microscopy (TEM. TEM observations confirmed the presence of rotation-ordered domains in plates, and some unexpected contrast could be explained by double diffraction due to overlapping phases.

  7. The experimental electron mean-free-path in Si under typical (S)TEM conditions

    International Nuclear Information System (INIS)

    Potapov, P.L.

    2014-01-01

    The electron mean-free-path in Si was measured by EELS using the test structure with the certified dimensions as a calibration standard. In a good agreement with the previous CBED measurements, the mean-free-path is 150 nm for 200 keV and 179 nm for 300 keV energy of primary electrons at large collection angles. These values are accurately predicted by the model of Iakoubovskii et al. while the model of Malis et al. incorporated in common microscopy software underestimates the mean-free-path by 15% at least. Correspondingly, the thickness of TEM samples reported in many studies of the Si-based materials last decades might be noticeably underestimated. - Highlights: • The electron inelastic mean-free-path in Si is measured for the typical (S)TEM conditions. • These reference values allow for accurate determination of the lamella thickness by EELS. • The theoretical model by Malis et al. underestimates the mean-free-path values

  8. The growing need for analytical quality control

    International Nuclear Information System (INIS)

    Suschny, O.; Richman, D.M.

    1974-01-01

    Technological development in a country is directly dependent upon its analytical chemistry or measurement capability, because it is impossible to achieve any level of technological sophistication without the ability to measure. Measurement capability is needed to determine both technological competence and technological consequence. But measurement itself is insufficient. There must be a standard or a reference for comparison. In the complicated world of chemistry the need for reference materials grows with successful technological development. The International Atomic Energy Agency has been distributing calibrated radioisotope solutions, standard reference materials and intercomparison materials since the early 1960's. The purpose of this activity has been to help laboratories in its Member States to assess and, if necessary, to improve the reliability of their analytical work. The value and continued need of this service has been demonstrated by the results of many intercomparisons which proved that without continuing analytical quality control activities, adequate reliability of analytical data could not be taken for granted. Analytical chemistry, lacking the glamour of other aspects of the physical sciences, has not attracted the attention it deserves, but in terms of practical importance, it warrants high priority in any developing technological scheme, because without it there is little chance to evaluate technological success or failure or opportunity to identify the reasons for success or failure. The scope and the size of the future programme of the IAEA in this field has been delineated by recommendations made by several Panels of Experts; all have agreed on the importance of this programme and made detailed recommendations in their areas of expertise. The Agency's resources are limited and it cannot on its own undertake the preparation and distribution of all the materials needed. It can, however, offer a focal point to bring together different

  9. Statistical Approaches to Assess Biosimilarity from Analytical Data.

    Science.gov (United States)

    Burdick, Richard; Coffey, Todd; Gutka, Hiten; Gratzl, Gyöngyi; Conlon, Hugh D; Huang, Chi-Ting; Boyne, Michael; Kuehne, Henriette

    2017-01-01

    Protein therapeutics have unique critical quality attributes (CQAs) that define their purity, potency, and safety. The analytical methods used to assess CQAs must be able to distinguish clinically meaningful differences in comparator products, and the most important CQAs should be evaluated with the most statistical rigor. High-risk CQA measurements assess the most important attributes that directly impact the clinical mechanism of action or have known implications for safety, while the moderate- to low-risk characteristics may have a lower direct impact and thereby may have a broader range to establish similarity. Statistical equivalence testing is applied for high-risk CQA measurements to establish the degree of similarity (e.g., highly similar fingerprint, highly similar, or similar) of selected attributes. Notably, some high-risk CQAs (e.g., primary sequence or disulfide bonding) are qualitative (e.g., the same as the originator or not the same) and therefore not amenable to equivalence testing. For biosimilars, an important step is the acquisition of a sufficient number of unique originator drug product lots to measure the variability in the originator drug manufacturing process and provide sufficient statistical power for the analytical data comparisons. Together, these analytical evaluations, along with PK/PD and safety data (immunogenicity), provide the data necessary to determine if the totality of the evidence warrants a designation of biosimilarity and subsequent licensure for marketing in the USA. In this paper, a case study approach is used to provide examples of analytical similarity exercises and the appropriateness of statistical approaches for the example data.

  10. Comparison of analytical and Monte Carlo calculations of multi-photon effects in bremsstrahlung emission by high-energy electrons

    DEFF Research Database (Denmark)

    Mangiarotti, Alessio; Sona, Pietro; Ballestrero, Sergio

    2012-01-01

    Approximate analytical calculations of multi-photon effects in the spectrum of total radiated energy by high-energy electrons crossing thin targets are compared to the results of Monte Carlo type simulations. The limits of validity of the analytical expressions found in the literature are establi...

  11. Enhancement of TEM Data and Noise Characterization by Principal Component Analysis

    Science.gov (United States)

    2010-05-01

    include simply thresholding a noise level and ignoring any signal below the chosen value ( Pasion and Oldenburg, 2001b), stacking, and median filters...to de-trend the data ( Pasion and Oldenburg, 2001a). To date, there has not been a concentrated research effort focused on separating the various...Negative values not displayed) 27 Magnetic soil at Kaho’olawe (and in general) exhibits a t−1 decay in TEM surveys ( Pasion et al., 2002). This signal

  12. Characterization of carbonated serpentine using XPS and TEM

    International Nuclear Information System (INIS)

    Schulze, Roland K.; Hill, Mary Ann; Field, Robert D.; Papin, Pallas A.; Hanrahan, Robert J.; Byler, Darrin D.

    2004-01-01

    With the increasing concentration volume of carbon dioxide in the atmosphere, there has been an increasing interest in carbon dioxide sequestration. One method is to store the carbon dioxide in mineral form, reacting solution dissolved CO 2 to precipitate carbonates. In order to understand whether or not such an endeavor is feasible, the carbonation reaction must first be understood. In this study, the surface of ground serpentine, untreated, heat treated and following a carbonation experiment, has been characterized using X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM). The results indicate that the mechanism for the reaction involves dissolution of the serpentine through the formation of an amorphous phase and subsequent precipitation of magnesite. The rate limiting step appears to be the diffusion of Mg out of the amorphous phase

  13. Analytical dose modeling for preclinical proton irradiation of millimetric targets.

    Science.gov (United States)

    Vanstalle, Marie; Constanzo, Julie; Karakaya, Yusuf; Finck, Christian; Rousseau, Marc; Brasse, David

    2018-01-01

    Due to the considerable development of proton radiotherapy, several proton platforms have emerged to irradiate small animals in order to study the biological effectiveness of proton radiation. A dedicated analytical treatment planning tool was developed in this study to accurately calculate the delivered dose given the specific constraints imposed by the small dimensions of the irradiated areas. The treatment planning system (TPS) developed in this study is based on an analytical formulation of the Bragg peak and uses experimental range values of protons. The method was validated after comparison with experimental data from the literature and then compared to Monte Carlo simulations conducted using Geant4. Three examples of treatment planning, performed with phantoms made of water targets and bone-slab insert, were generated with the analytical formulation and Geant4. Each treatment planning was evaluated using dose-volume histograms and gamma index maps. We demonstrate the value of the analytical function for mouse irradiation, which requires a targeting accuracy of 0.1 mm. Using the appropriate database, the analytical modeling limits the errors caused by misestimating the stopping power. For example, 99% of a 1-mm tumor irradiated with a 24-MeV beam receives the prescribed dose. The analytical dose deviations from the prescribed dose remain within the dose tolerances stated by report 62 of the International Commission on Radiation Units and Measurements for all tested configurations. In addition, the gamma index maps show that the highly constrained targeting accuracy of 0.1 mm for mouse irradiation leads to a significant disagreement between Geant4 and the reference. This simulated treatment planning is nevertheless compatible with a targeting accuracy exceeding 0.2 mm, corresponding to rat and rabbit irradiations. Good dose accuracy for millimetric tumors is achieved with the analytical calculation used in this work. These volume sizes are typical in mouse

  14. Direct Observations of Oxygen-induced Platinum Nanoparticle Ripening Studied by In Situ TEM

    DEFF Research Database (Denmark)

    Simonsen, Søren Bredmose; Chorkendorff, Ib; Dahl, Søren

    2010-01-01

    This study addresses the sintering mechanism of Pt nanoparticles dispersed on a planar, amorphous Al2O3 support as a model system for a catalyst for automotive exhaust abatement. By means of in situ transmission electron microscopy (TEM), the model catalyst was monitored during the exposure to 10...

  15. Proceedings of 11. Conference on Electron Microscopy of Solids

    International Nuclear Information System (INIS)

    2002-01-01

    The conference is the cyclically organised discussion forum on problems connected with application of different electron microscopy techniques for the study of solid state materials. The main topics of 11 conference on Electron Microscopy of Solids held in Krynica (PL) in 2002 was: application of TEM in materials science; analytical techniques and orientation imaging in materials science; high resolution TEM in electronic materials; TEM and SEM application in ceramic and composites; advanced TEM techniques; advanced analytical and orientation imaging techniques; application of TEM in investigations of amorphous and nanocrystalline material; Intermetallic and superalloys; TEM application in martensite alloys; TEM and SEM application in research of iron base alloys; TEM studies of deformed alloys; TEM application in thin films and surface layer studies; TEM and SEM application in materials science

  16. A high-resolution analytical scanning transmission electron microscopy study of the early stages of spinodal decomposition in binary Fe–Cr

    International Nuclear Information System (INIS)

    Westraadt, J.E.; Olivier, E.J.; Neethling, J.H.; Hedström, P.; Odqvist, J.; Xu, X.; Steuwer, A.

    2015-01-01

    Spinodal decomposition (SD) is an important phenomenon in materials science and engineering. For example, it is considered to be responsible for the 475 °C embrittlement of stainless steels comprising the bcc (ferrite) or bct (martensite) phases. Structural characterization of the evolving minute nano-scale concentration fluctuations during SD in the Fe–Cr system is, however, a notable challenge, and has mainly been considered accessible via atom probe tomography (APT) and small-angle neutron scattering. The standard tool for nanostructure characterization, viz. transmission electron microscopy (TEM), has only been successfully applied to late stages of SD when embrittlement is already severe. However, we here demonstrate that the structural evolution in the early stages of SD in binary Fe–Cr, and alloys based on the binary, are accessible via analytical scanning TEM. An Fe–36 wt% Cr alloy aged at 500 °C for 1, 10 and 100 h is investigated using an aberration-corrected microscope and it is found that highly coherent and interconnected Cr-rich regions develop. The wavelength of decomposition is rather insensitive to the sample thickness and it is quantified to 2, 3 and 6 nm after ageing for 1, 10 and 100 h, which is in reasonable agreement with prior APT analysis. The concentration amplitude is more sensitive to the sample thickness and acquisition parameters but the TEM analysis is in good agreement with APT analysis for the longest ageing time. These findings open up for combinatorial TEM studies where both local crystallography and chemistry is required. - Highlights: • STEM-EELS analysis was successfully applied to resolve early stage SD in Fe–Cr. • Compositional wavelength measured with STEM-EELS compares well to previous ATP studies. • Compositional amplitude measured with STEM-EELS is a function of experimental parameters. • STEM-EELS allows for combinatorial studies of SD using complementary techniques.

  17. A high-resolution analytical scanning transmission electron microscopy study of the early stages of spinodal decomposition in binary Fe–Cr

    Energy Technology Data Exchange (ETDEWEB)

    Westraadt, J.E., E-mail: johan.westraadt@nmmu.ac.za [Centre for High Resolution TEM, Nelson Mandela Metropolitan University, University Way, Port Elizabeth 6031 (South Africa); Olivier, E.J.; Neethling, J.H. [Centre for High Resolution TEM, Nelson Mandela Metropolitan University, University Way, Port Elizabeth 6031 (South Africa); Hedström, P.; Odqvist, J.; Xu, X. [Dept. Materials Science and Engineering, KTH Royal Institute of Technology, Brinellvägen 23, 10044 Stockholm (Sweden); Steuwer, A. [Nelson Mandela Metropolitan University, Gardham Av., Port Elizabeth 6031 (South Africa)

    2015-11-15

    Spinodal decomposition (SD) is an important phenomenon in materials science and engineering. For example, it is considered to be responsible for the 475 °C embrittlement of stainless steels comprising the bcc (ferrite) or bct (martensite) phases. Structural characterization of the evolving minute nano-scale concentration fluctuations during SD in the Fe–Cr system is, however, a notable challenge, and has mainly been considered accessible via atom probe tomography (APT) and small-angle neutron scattering. The standard tool for nanostructure characterization, viz. transmission electron microscopy (TEM), has only been successfully applied to late stages of SD when embrittlement is already severe. However, we here demonstrate that the structural evolution in the early stages of SD in binary Fe–Cr, and alloys based on the binary, are accessible via analytical scanning TEM. An Fe–36 wt% Cr alloy aged at 500 °C for 1, 10 and 100 h is investigated using an aberration-corrected microscope and it is found that highly coherent and interconnected Cr-rich regions develop. The wavelength of decomposition is rather insensitive to the sample thickness and it is quantified to 2, 3 and 6 nm after ageing for 1, 10 and 100 h, which is in reasonable agreement with prior APT analysis. The concentration amplitude is more sensitive to the sample thickness and acquisition parameters but the TEM analysis is in good agreement with APT analysis for the longest ageing time. These findings open up for combinatorial TEM studies where both local crystallography and chemistry is required. - Highlights: • STEM-EELS analysis was successfully applied to resolve early stage SD in Fe–Cr. • Compositional wavelength measured with STEM-EELS compares well to previous ATP studies. • Compositional amplitude measured with STEM-EELS is a function of experimental parameters. • STEM-EELS allows for combinatorial studies of SD using complementary techniques.

  18. Studying the TEM response of a 3-D conductor at a geological contact using the FDTD method

    Energy Technology Data Exchange (ETDEWEB)

    Wang, T.; Tripp, A.C.; Hohmann, G.W. [Univ. of Utah, Salt Lake City, UT (United States). Dept. of Geology and Geophysics

    1995-07-01

    Many mineral targets are located near contact zones. Since the change of resistivity across the contact can distort or obscure the transient electromagnetic (TEM) response of the target, it is important to understand the possible effects. Previous investigators have examined similar problems using scale models. For example, Spies and Parker (1984) studied the TEM responses of fixed-loop and moving-loop configurations to geological contacts with lateral resistivity variations. More recently, Wilt (1991) systematically studied TEM soundings near a geological contact and observed that different survey systems respond to the contact in different ways. This paper will illustrate the use of the finite-difference, time-domain (FDTD) algorithm of Wang and Hohmann (1993) for calculating the TEM response of a 3-D conductive body at a geological contact. The algorithm is based on the Yee staggered grid FDTD method for solving the transient electrical nonmagnetic field responses of a 3-D model. On a suitable computer, a wide range of model responses can be readily calculated, a versatility that scale modeling does not share. This study uses a fixed transmitter loop, roving-receiver configuration. Many other configurations can be regarded as special cases of this survey. It is commonly employed, for instance, by the Newmont EMP (Body and Wiles, 1984), UTEM (West et al., 1984), and Geonics EM37 systems. The configuration also facilitates finite-difference, time-domain modeling because it does not require frequent movement of the source.

  19. Analytical approximate solutions of the time-domain diffusion equation in layered slabs.

    Science.gov (United States)

    Martelli, Fabrizio; Sassaroli, Angelo; Yamada, Yukio; Zaccanti, Giovanni

    2002-01-01

    Time-domain analytical solutions of the diffusion equation for photon migration through highly scattering two- and three-layered slabs have been obtained. The effect of the refractive-index mismatch with the external medium is taken into account, and approximate boundary conditions at the interface between the diffusive layers have been considered. A Monte Carlo code for photon migration through a layered slab has also been developed. Comparisons with the results of Monte Carlo simulations showed that the analytical solutions correctly describe the mean path length followed by photons inside each diffusive layer and the shape of the temporal profile of received photons, while discrepancies are observed for the continuous-wave reflectance or transmittance.

  20. Development of non-intrusive monitoring techniques - ESDRED and TEM projects at Mont Terri and the Grimsel test site

    International Nuclear Information System (INIS)

    Breen, B.; Johnson, M.; Frieg, B.; Blechschmidt, I.; Manukyan, E.; Marelli, S.; Maurer, H.R.

    2008-01-01

    , this being part of another study, funded with in the ESDRED programme. The TEM (Testing and Evaluation of Monitoring Techniques) Project at Grimsel was initiated to provide a unique opportunity for simultaneous comparison of 3 monitoring methods - wired signal transmission from the EBS, wireless data transmission using magneto-inductive techniques, and observation through non-intrusive geophysical techniques. The novelty of TEM is that the application of each of these techniques is under a realistic condition, where a bentonite barrier is emplaced in a 3.5 m diameter tunnel and isolated with an approximately 4 m long low-pH shotcrete plug. The report describes the work programmes and some of the results from the ESDRED and TEM programmes at both sites. (author)