WorldWideScience

Sample records for analogs potential positron

  1. Low-energy positron-argon collisions by using parameter-free positron correlation polarization potentials

    International Nuclear Information System (INIS)

    Jain, A.

    1990-01-01

    We report differential, integral, and momentum-transfer cross sections and the scattering length (A 0 ) for positron (e + )-argon scattering at low energies below the positronium formation threshold. An optical-potential approach is employed in which the repulsive Coulombic interaction is calculated exactly at the Hartree-Fock level and the attractive polarization and correlation effects are included approximately via a parameter-free positron correlation polarization (PCP) potential recently proposed by us. The PCP model is based on the correlation energy var-epsilon corr of one positron in a homogeneous electron gas; in the outside region, the var-epsilon corr is joined smoothly with the correct asymptotic form of the polarization interaction (-α 0 /2r 4 , where α 0 is the target polarizability) where they cross each other for the first time. The total optical potential of the e + -argon system is treated exactly in a partial-wave analysis to extract the scattering parameters. It is found that the PCP potential gives much better qualitative results, particularly for the differential cross sections and the scattering length, than the corresponding results obtained from an electron polarization potential used as such for the positron case. We also discuss the ''critical'' points (representing the minima in the differential scattering) in the low-energy e + -Ar scattering. The present results involve no fitting procedure

  2. New parameter-free polarization potentials in low-energy positron collisions

    Science.gov (United States)

    Jain, Ashok

    1990-01-01

    The polarization potential plays a decisive role in shaping up the cross sections in low energy positron collisions with atoms and molecules. However, its inclusion without involving any adjustable parameter, is still a challenge. Various other techniques employed so far for positron collisions are summarized, and a new, nonadjustable and very simple form of the polarization potential for positron-atom (molecule) collisions below the threshold of positronium formation is discussed. This new recently proposed potential is based on the correlation energy of a single positron in a homogeneous electron gas. The correlation energy was calculated by solving the Schrodinger equation of the positron-electron system and fitted to an analytical form in various ranges of the density parameter. In the outside region, the correlation energy is joined smoothly with the correct asymptotic form. This new positron correlation polarization (PCOP) potential was tested on several atomic and molecular targets such as the Ar, CO, and CH4. The results on the total and differential cross sections on these targets are shown along with the experimental data where available.

  3. Threshold law for positron-atom impact ionisation

    International Nuclear Information System (INIS)

    Temkin, A.

    1982-01-01

    The threshold law for ionisation of atoms by positron impact is adduced in analogy with the author's approach to the electron-atom ionisation. It is concluded the Coulomb-dipole region of potential gives the essential part of the interaction in both cases and leads to the same kind of result: a modulated linear law. An additional process which enters positron ionisation is positronium formation in the continuum, but that will not dominate the threshold yield. The result is in sharp contrast to the positron threshold law as recently derived by Klar (J. Phys. B.; 14:4165 (1981)) on the basis of a Wannier-type (Phys. Rev.; 90:817 (1953)) analysis. (author)

  4. Is the positron a light proton. Contrasts of positron/proton analogies in small molecules

    International Nuclear Information System (INIS)

    Cade, P.E.; Kao, C.-M.

    1982-01-01

    The nature of positron behavior in [M - :e + ] systems is explored. Here M - is a molecular anion which combines with a proton to form a stable system, HM. The sharp distinction between the positron and proton dynamics does not entirely remove common characteristics of these systems. Examples are given for HM versus [M - :e + ] systems with M - = (H - , SH - , CN - , and N 3- ). In addition, the possibilities of a 'positronium' bond versus a hydrogen bond are discussed. (Auth.)

  5. Positron emission tomography

    International Nuclear Information System (INIS)

    Yamamoto, Y.L.; Thompson, C.J.; Diksic, M.; Meyer, E.; Feindel, W.H.

    1984-01-01

    One of the most exciting new technologies introduced in the last 10 yr is positron emission tomography (PET). PET provides quantitative, three-dimensional images for the study of specific biochemical and physiological processes in the human body. This approach is analogous to quantitative in-vivo autoradiography but has the added advantage of permitting non-invasive in vivo studies. PET scanning requires a small cyclotron to produce short-lived positron emitting isotopes such as oxygen-15, carbon-11, nitrogen-13 and fluorine-18. Proper radiochemical facilities and advanced computer equipment are also needed. Most important, PET requires a multidisciplinary scientific team of physicists, radiochemists, mathematicians, biochemists and physicians. The most recent trends are reviewed in the imaging technology, radiochemistry, methodology and clinical applications of positron emission tomography. (author)

  6. Semiempirical potentials for positron scattering by atoms

    Energy Technology Data Exchange (ETDEWEB)

    Assafrao, Denise; Walters, H. R. J.; Arretche, Felipe; Dutra, Adriano; Mohallem, J. R. [Departamento de Fisica, Universidade Federal do Espirito Santo, 29075-910, Vitoria, ES (Brazil); Department of Applied Mathematics and Theoretical Physics, Queen' s University, Belfast, BT7 1NN (United Kingdom); Departamento de Fisica, Universidade do Estado de Santa Catarina, 89223-100, Joinville, SC (Brazil); Laboratorio de Atomos e Moleculas Especiais, Departamento de Fisica, ICEx, Universidade Federal de Minas Gerais, PO Box 702, 30123-970, Belo Horizonte, MG (Brazil)

    2011-08-15

    We report calculations of differential and integral cross sections for positron scattering by noble gas and alkaline-earth atoms within the same methodology. The scattering potentials are constructed by scaling adiabatic potentials so that their minima coincide with the covalent radii of the target atoms. Elastic differential and integral cross sections are calculated for Ne, Ar, Be, and Mg, and the results are very close to experimental and best theoretical data. Particularly, elastic differential cross sections for Be and Mg at low energies are reported.

  7. Potentials of positron emission tomography for regional cerebral blood flow evaluation

    International Nuclear Information System (INIS)

    Depresseux, J.C.

    1982-01-01

    A general overview of the potentials of positron emission tomography and of positron-emitting radiopharmaceuticals for the evaluation of regional cerebral blood flow is proposed and discussed. Specific characteristics of this technique are described, with special stress on conceptual and methodological implications. Four different approaches to the problem of the determination of cerebral blood flow are distinguished: trapping equilibrium methods, steady state equilibrium methods, clearance methods and convoluted kinetic methods [fr

  8. Pumping Electron-Positron Pairs from a Well Potential.

    Science.gov (United States)

    Wang, Qiang; Liu, Jie; Fu, Li-Bin

    2016-04-29

    In the presence of very deep well potential, electrons will spontaneously occupy the empty embedded bound states and electron-positron pairs are created by means of a non-perturbative tunneling process. In this work, by slowly oscillating the width or depth, the population transfer channels are opened and closed periodically. We find and clearly show that by the non-synchronous ejections of particles, the saturation of pair number in a static super-critical well can be broken, and electrons and positrons can be pumped inexhaustibly from vacuum with a constant production rate. In the adiabatic limit, final pair number after a single cycle has quantized values as a function of the upper boundary of the oscillating, and the critical upper boundaries indicate the diving points of the bound states.

  9. Digital positron lifetime: the influence of noise

    International Nuclear Information System (INIS)

    Krille, Arnold; Krause-Rehberg, Reinhard; Anwand, Wolfgang

    2011-01-01

    In contrast to the world around where everything seems to go digital as soon as possible, positron lifetime spectrometers are kind of a 'last sanctuary' for analog measurements. Only a few of the newer spectrometers use the analog-digital-converters directly after the photomultipliers and extract the timing information via computer. Judging from their results it seems as if the current available converters and the timing mathematics are only as good as the conventional analog setup in the timing resolution. As it is decided that EPOS [1] will use digital positron lifetime, we try to find some reasons for limited timing resolution by simulating anode pulses from the photomultipliers and measuring the FWHM. We create pulses similar to current state-of-the-art 4GS/s digitizers but can control the level of noise and the bit-depth independently. We found that especially the noise (that would come from the analog electronics in/before the converters) has a great influence on the timing resolution. Also we try to use lowpass filtering to reduce that influence with great success.

  10. Digital positron lifetime: the influence of noise

    Energy Technology Data Exchange (ETDEWEB)

    Krille, Arnold; Krause-Rehberg, Reinhard [Department of Physics, Martin-Luther-University Halle-Wittenberg, 06099 Halle (Germany); Anwand, Wolfgang, E-mail: arnold.krille@physik.uni-halle.de [Institute of Ion Beam Physics, Research Center Dresden-Rossendorf, 01314 Dresden (Germany)

    2011-01-10

    In contrast to the world around where everything seems to go digital as soon as possible, positron lifetime spectrometers are kind of a 'last sanctuary' for analog measurements. Only a few of the newer spectrometers use the analog-digital-converters directly after the photomultipliers and extract the timing information via computer. Judging from their results it seems as if the current available converters and the timing mathematics are only as good as the conventional analog setup in the timing resolution. As it is decided that EPOS [1] will use digital positron lifetime, we try to find some reasons for limited timing resolution by simulating anode pulses from the photomultipliers and measuring the FWHM. We create pulses similar to current state-of-the-art 4GS/s digitizers but can control the level of noise and the bit-depth independently. We found that especially the noise (that would come from the analog electronics in/before the converters) has a great influence on the timing resolution. Also we try to use lowpass filtering to reduce that influence with great success.

  11. Development of analog solid-state photo-detectors for Positron Emission Tomography

    International Nuclear Information System (INIS)

    Bisogni, Maria Giuseppina; Morrocchi, Matteo

    2016-01-01

    Solid-state photo-detectors are one of the main innovations of past century in the field of sensors. First produced in the early forties with the invention of the p–n junction in silicon and the study of its optical properties, photo-detectors received a major boost in the sixties when the p-i-n (PIN) photodiode was developed and successfully used in several applications. The development of devices with internal gain, avalanche photodiodes (APD) first and then Geiger-mode avalanche photodiodes, named single photon avalanche diode (SPAD), leads to a substantial improvement in sensitivity and allowed single photon detection. Later on, thousands of SPADs have been assembled in arrays of few millimeters squared (named SiPM, silicon photo-multiplier) with single photon resolution. The high internal gain of SiPMs, together with other features peculiar of the silicon technology like compactness, speed and compatibility with magnetic fields, promoted SiPMs as the principal photo-detector competitor of photomultipliers in many applications from radiation detection to medical imaging. This paper provides a review of the properties of analog solid-state photo-detectors. Particular emphasis is given to latest advances on Positron Emission Tomography instrumentation boosted by the adoption of the silicon photo-detectors as an alternative to photomultiplier tubes (PMTs). Special attention is dedicated to the SiPMs, which are playing a key role in the development of innovative scanners.

  12. Development of analog solid-state photo-detectors for Positron Emission Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bisogni, Maria Giuseppina, E-mail: giuseppina.bisogni@pi.infn.it; Morrocchi, Matteo

    2016-02-11

    Solid-state photo-detectors are one of the main innovations of past century in the field of sensors. First produced in the early forties with the invention of the p–n junction in silicon and the study of its optical properties, photo-detectors received a major boost in the sixties when the p-i-n (PIN) photodiode was developed and successfully used in several applications. The development of devices with internal gain, avalanche photodiodes (APD) first and then Geiger-mode avalanche photodiodes, named single photon avalanche diode (SPAD), leads to a substantial improvement in sensitivity and allowed single photon detection. Later on, thousands of SPADs have been assembled in arrays of few millimeters squared (named SiPM, silicon photo-multiplier) with single photon resolution. The high internal gain of SiPMs, together with other features peculiar of the silicon technology like compactness, speed and compatibility with magnetic fields, promoted SiPMs as the principal photo-detector competitor of photomultipliers in many applications from radiation detection to medical imaging. This paper provides a review of the properties of analog solid-state photo-detectors. Particular emphasis is given to latest advances on Positron Emission Tomography instrumentation boosted by the adoption of the silicon photo-detectors as an alternative to photomultiplier tubes (PMTs). Special attention is dedicated to the SiPMs, which are playing a key role in the development of innovative scanners.

  13. Binding matter with antimatter: the covalent positron bond.

    Science.gov (United States)

    Charry, Jorge Alfonso; Varella, Marcio T Do N; Reyes, Andrés

    2018-05-16

    We report sufficient theoretical evidence of the energy stability of the e⁺H₂²⁻ molecule, formed by two H⁻ anions and one positron. Analysis of the electronic and positronic densities of the latter compound undoubtedly points out the formation of a positronic covalent bond between the otherwise repelling hydride anions. The lower limit for the bonding energy of the e⁺H₂²⁻ molecule is 74 kJ/mol (0.77 eV), accounting for the zero-point vibrational correction. The formation of a non electronic covalent bond is fundamentally distinct from positron attachment to stable molecules, as the latter process is characterized by a positron affinity, analogous to the electron affinity. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Digital positron lifetime spectroscopy: present status and outlook

    International Nuclear Information System (INIS)

    Becvar, F.

    2007-01-01

    This contribution summarizes achievements in instrumentation for positron lifetime measurements with emphasis on digital spectrometric systems. A significant part of the data presented are based on a long-term exploitation of a conventional positron lifetime spectrometer developed at Charles University in early 90s, on bench-mark testing measurements with this spectrometer working temporarily in conjunction with a pair of 8-bit, 4 GS/s digitizers and on analogous measurements with a recently assembled digital positron lifetime spectrometer. In addition, results from testing experiments with microchannel plate photomultipliers are briefly reported. Further development of positron lifetime technique is discussed. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  15. Optical potential study of positron scattering by hydrogenic-type atoms

    International Nuclear Information System (INIS)

    Kuru Ratnavelu; Nithyanandan Natchimuthu; Kalai Kumar Rajgopal

    1999-01-01

    An optical potential method based on the close-coupling formalism has been implemented to study positron scattering by hydrogenic-type atoms. The present work will be reviewed in the context of other theories. Preliminary results will be presented and compared with experimental results. (author)

  16. High resolution tomography using analog coding

    International Nuclear Information System (INIS)

    Brownell, G.L.; Burnham, C.A.; Chesler, D.A.

    1985-01-01

    As part of a 30-year program in the development of positron instrumentation, the authors have developed a high resolution bismuth germanate (BGO) ring tomography (PCR) employing 360 detectors and 90 photomultiplier tubes for one plane. The detectors are shaped as trapezoid and are 4 mm wide at the front end. When assembled, they form an essentially continuous cylindrical detector. Light from a scintillation in the detector is viewed through a cylindrical light pipe by the photomultiplier tubes. By use of an analog coding scheme, the detector emitting light is identified from the phototube signals. In effect, each phototube can identify four crystals. PCR is designed as a static device and does not use interpolative motion. This results in considerable advantage when performing dynamic studies. PCR is the positron tomography analog of the γ-camera widely used in nuclear medicine

  17. Synthesis, enantiomeric resolution, F-18 labeling and biodistribution of reboxetine analogs: promising radioligands for imaging the norepinephrine transporter with positron emission tomography.

    Science.gov (United States)

    Lin, Kuo-Shyan; Ding, Yu-Shin; Kim, Sung-Won; Kil, Kun-Eek

    2005-05-01

    Racemic and enantiomerically pure ((S,S) and (R,R)) 2-[alpha-(2-(2-[(18)F]fluoroethoxy)phenoxy)benzyl]morpholine ([(18)F]FRB) and its tetradeuterated form [(18)F]FRB-D(4), analogs of the highly selective norepinephrine reuptake inhibitor reboxetine (2-[alpha-(2-ethoxyphenoxy)benzyl]morpholine, RB), have been synthesized for studies of norepinephrine transporter (NET) system with positron emission tomography (PET). The [(18)F]fluorinated precursor, (S,S)/(R,R)-N-tert-butyloxycarbonyl-2-[alpha-(2-hydroxyphenoxy)benzyl]morpholine ((S,S)/(R,R)-N-Boc-desethylRB), was prepared by the N-protection of (S,S)/(R,R)-2-[alpha-(2-hydroxyphenoxy)benzyl]morpholine ((S,S)/(R,R)-desethylRB) with a tert-butyloxycarbonyl (Boc) group followed by enantiomeric resolution with chiral HPLC to provide both (S,S) and (R,R) enantiomers with >99% enantiomeric purity. These compounds were then used for radiosynthesis to prepare enantiomerically pure [(18)F]FRB and [(18)F]FRB-D(4) via the following three-step procedure: (1) formation of 1-bromo-2-[(18)F]fluoroethane ([(18)F]BFE or [(18)F]BFE-D(4)) by nucleophilic displacement of 2-bromoethyl triflate (or D(4) analog) with no-carrier added [(18)F]F(-) in THF; (2) reaction of [(18)F]BFE (or [(18)F]BFE-D(4)) with N-Boc-desethylRB in DMF in the presence of excess base; and (3) deprotection with trifluoroacetic acid. The racemates, (S,S) and (R,R) enantiomers of [(18)F]FRB and [(18)F]FRB-D(4) were obtained in 11-27% (decay corrected to the end of bombardment, EOB) in 120-min synthesis time with a radiochemical purity of >98% and specific activities of 21-48 GBq/micromol (EOB). The results of the whole-body biodistribution studies with (S,S)-[(18)F]FRB-D(4) were similar to those with (S,S)-[(18)F]FRB but showed relatively faster blood clearance and no significant in vivo defluorination. Positron emission tomography studies in baboon brain also showed that (S,S)-[(18)F]FRB-D(4) may be a potentially useful ligand for imaging NET with PET.

  18. Synthesis, enantiomeric resolution, F-18 labeling and biodistribution of reboxetine analogs: promising radioligands for imaging the norepinephrine transporter with positron emission tomography

    International Nuclear Information System (INIS)

    Lin, K.-S.; Ding, Y.-S.; Kim, Sung-Won; Kil, Kun-Eek

    2005-01-01

    Racemic and enantiomerically pure ((S,S) and (R,R)) 2-[α-(2-(2-[ 18 F]fluoroethoxy)phenoxy)benzyl]morpholine ([ 18 F]FRB) and its tetradeuterated form [ 18 F]FRB-D 4 , analogs of the highly selective norepinephrine reuptake inhibitor reboxetine (2-[α-(2-ethoxyphenoxy)benzyl]morpholine, RB), have been synthesized for studies of norepinephrine transporter (NET) system with positron emission tomography (PET). The [ 18 F]fluorinated precursor, (S,S)/(R,R)-N-tert-butyloxycarbonyl-2-[α-(2-hydroxyphenoxy)benzyl] morpholine ((S,S)/(R,R)-N-Boc-desethylRB), was prepared by the N-protection of (S,S)/(R,R)-2-[α-(2-hydroxyphenoxy)benzyl]morpholine ((S,S)/(R,R)-desethylRB) with a tert-butyloxycarbonyl (Boc) group followed by enantiomeric resolution with chiral HPLC to provide both (S,S) and (R,R) enantiomers with >99% enantiomeric purity. These compounds were then used for radiosynthesis to prepare enantiomerically pure [ 18 F]FRB and [ 18 F]FRB-D 4 via the following three-step procedure: (1) formation of 1-bromo-2-[ 18 F]fluoroethane ([ 18 F]BFE or [ 18 F]BFE-D 4 ) by nucleophilic displacement of 2-bromoethyl triflate (or D 4 analog) with no-carrier added [ 18 F]F - in THF; (2) reaction of [ 18 F]BFE (or [ 18 F]BFE-D 4 ) with N-Boc-desethylRB in DMF in the presence of excess base; and (3) deprotection with trifluoroacetic acid. The racemates, (S,S) and (R,R) enantiomers of [ 18 F]FRB and [ 18 F]FRB-D 4 were obtained in 11-27% (decay corrected to the end of bombardment, EOB) in 120-min synthesis time with a radiochemical purity of >98% and specific activities of 21-48 GBq/μmol (EOB). The results of the whole-body biodistribution studies with (S,S)-[ 18 F]FRB-D 4 were similar to those with (S,S)-[ 18 F]FRB but showed relatively faster blood clearance and no significant in vivo defluorination. Positron emission tomography studies in baboon brain also showed that (S,S)-[ 18 F]FRB-D 4 may be a potentially useful ligand for imaging NET with PET

  19. Positron-containing systems and positron diagnostics

    International Nuclear Information System (INIS)

    1978-01-01

    The results of the experimental and theoretical investigations are presented. Considered are quantum-mechanical calculations of wave functions describing the states of positron-containing atomic systems and of cross-sections of the processes characterizing different interactions, and also the calculations of the behaviour of positrons in gases in the presence of an electric field. The results of experimental tests are presented by the data describing the behaviour of positrons and positronium in liquids, polymers and elastomers, complex oxides and in different solids. New equipment and systems developed on the basis of current studies are described. Examined is a possibility of applying the methods of model and effective potentials for studying the bound states of positron systems and for calculating cross-sections of elementary processes of elastic and inelastic collisions with a positron involved. The experimental works described indicate new possibilities of the positron diagnosis method: investigation of thin layers and films of semiconductor materials, defining the nature of chemical bonds in semiconductors, determination of the dislocation density in deformed semiconductors, derivation of important quantitative information of the energy states of radiation defects in them

  20. Tracking cognitive phases in analogical reasoning with event-related potentials.

    Science.gov (United States)

    Maguire, Mandy J; McClelland, M Michelle; Donovan, Colin M; Tillman, Gail D; Krawczyk, Daniel C

    2012-03-01

    Analogical reasoning consists of multiple phases. Four-term analogies (A:B::C:D) have an encoding period in which the A:B pair is evaluated prior to a mapping phase. The electrophysiological timing associated with analogical reasoning has remained unclear. We used event-related potentials to identify neural timing related to analogical reasoning relative to perceptual and semantic control conditions. Spatiotemporal principal-components analyses revealed differences primarily in left frontal electrodes during encoding and mapping phases of analogies relative to the other conditions. The timing of the activity differed depending upon the phase of the problem. During the encoding of A:B terms, analogies elicited a positive deflection compared to the control conditions between 400 and 1,200 ms, but for the mapping phase analogical processing elicited a negative deflection that occurred earlier and for a shorter time period, between 350 and 625 ms. These results provide neural and behavioral evidence that 4-term analogy problems involve a highly active evaluation phase of the A:B pair. 2012 APA, all rights reserved

  1. F-18-fluorodeoxyglucose-positron emission tomography in colorectal cancer

    International Nuclear Information System (INIS)

    Joerg, L.; Langsteger, W.

    2002-01-01

    Whole-body positron emission tomography (PET) with the radiolabeled glucose analog F-18-fluorodeoxyglucose (F-18-FDG) is a sensitive diagnostic tool that images tumors based on increased uptake of glucose. Several recent publications have shown that F-18-fluorodeoxyglucose-positron emission tomography is more sensitive than computed-tomography (CT) in detecting colorectal cancer. In patients with increasing CEA (carcinoembryonic antigen) and no evidence of recurrent disease on CT F-18-fluorodeoxyglucose-positron emission tomography often detects recurrent cancer. In all, patient management seems to be changed in about 25 % of patients who undergo F-18-fluorodeoxyglucose-positron emission tomography in addition to standard staging procedure. Limited reports to date on both chemotherapy and radiotherapy support the role of F-18-fluorodeoxyglucose-positron emission tomography in assessing treatment response. Also regarding preoperative staging of primary colorectal cancer the literature is very limited. (author)

  2. Low-energy positron interactions with atoms and molecules

    International Nuclear Information System (INIS)

    Surko, C M; Gribakin, G F; Buckman, S J

    2005-01-01

    This paper is a review of low-energy positron interactions with atoms and molecules. Processes of interest include elastic scattering, electronic and vibrational excitation, ionization, positronium formation and annihilation. An overview is presented of the currently available theoretical and experimental techniques to study these phenomena, including the use of trap-based positron beam sources to study collision processes with improved energy resolution. State-resolved measurements of electronic and vibrational excitation cross sections and measurement of annihilation rates in atoms and molecules as a function of incident positron energy are discussed. Where data are available, comparisons are made with analogous electron scattering cross sections. Resonance phenomena, common in electron scattering, appear to be less common in positron scattering. Possible exceptions include the sharp onsets of positron-impact electronic and vibrational excitation of selected molecules. Recent energy-resolved studies of positron annihilation in hydrocarbons containing more than a few carbon atoms provide direct evidence that vibrational Feshbach resonances underpin the anomalously large annihilation rates observed for many polyatomic species. We discuss open questions regarding this process in larger molecules, as well as positron annihilation in smaller molecules where the theoretical picture is less clear. (topical review)

  3. 4.5 Tesla magnetic field reduces range of high-energy positrons -- Potential implications for positron emission tomography

    International Nuclear Information System (INIS)

    Wirrwar, A.; Vosberg, H.; Herzog, H.; Halling, H.; Weber, S.; Mueller-Gaertner, H.W.; Forschungszentrum Juelich GmbH

    1997-01-01

    The authors have theoretically and experimentally investigated the extent to which homogeneous magnetic fields up to 7 Tesla reduce the spatial distance positrons travel before annihilation (positron range). Computer simulations of a noncoincident detector design using a Monte Carlo algorithm calculated the positron range as a function of positron energy and magnetic field strength. The simulation predicted improvements in resolution, defined as full-width at half-maximum (FWHM) of the line-spread function (LSF) for a magnetic field strength up to 7 Tesla: negligible for F-18, from 3.35 mm to 2.73 mm for Ga-68 and from 3.66 mm to 2.68 mm for Rb-82. Also a substantial noise suppression was observed, described by the full-width at tenth-maximum (FWTM) for higher positron energies. The experimental approach confirmed an improvement in resolution for Ga-68 from 3.54 mm at 0 Tesla to 2.99 mm FWHM at 4.5 Tesla and practically no improvement for F-18 (2.97 mm at 0 Tesla and 2.95 mm at 4.5 Tesla). It is concluded that the simulation model is appropriate and that a homogeneous static magnetic field of 4.5 Tesla reduces the range of high-energy positrons to an extent that may improve spatial resolution in positron emission tomography

  4. Positron emission computed tomography

    International Nuclear Information System (INIS)

    Grover, M.; Schelbert, H.R.

    1985-01-01

    Regional mycardial blood flow and substrate metabolism can be non-invasively evaluated and quantified with positron emission computed tomography (Positron-CT). Tracers of exogenous glucose utilization and fatty acid metabolism are available and have been extensively tested. Specific tracer kinetic models have been developed or are being tested so that glucose and fatty acid metabolism can be measured quantitatively by Positron-CT. Tracers of amino acid and oxygen metabolism are utilized in Positron-CT studies of the brain and development of such tracers for cardiac studies are in progress. Methods to quantify regional myocardial blood flow are also being developed. Previous studies have demonstrated the ability of Positron-/CT to document myocardial infarction. Experimental and clinical studies have begun to identify metabolic markers of reversibly ischemic myocardium. The potential of Positron-CT to reliably detect potentially salvageable myocardium and, hence, to identify appropriate therapeutic interventions is one of the most exciting applications of the technique

  5. Synthesis, enantiomeric resolution, F-18 labeling and biodistribution of reboxetine analogs: promising radioligands for imaging the norepinephrine transporter with positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lin, K.-S. [Chemistry Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); Ding, Y.-S. [Chemistry Department, Brookhaven National Laboratory, Upton, New York 11973 (United States)]. E-mail: ding@bnl.gov; Kim, Sung-Won [Chemistry Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); Kil, Kun-Eek [Chemistry Department, Brookhaven National Laboratory, Upton, New York 11973 (United States)

    2005-05-01

    Racemic and enantiomerically pure ((S,S) and (R,R)) 2-[{alpha}-(2-(2-[{sup 18}F]fluoroethoxy)phenoxy)benzyl]morpholine ([{sup 18}F]FRB) and its tetradeuterated form [{sup 18}F]FRB-D{sub 4}, analogs of the highly selective norepinephrine reuptake inhibitor reboxetine (2-[{alpha}-(2-ethoxyphenoxy)benzyl]morpholine, RB), have been synthesized for studies of norepinephrine transporter (NET) system with positron emission tomography (PET). The [{sup 18}F]fluorinated precursor, (S,S)/(R,R)-N-tert-butyloxycarbonyl-2-[{alpha}-(2-hydroxyphenoxy)benzyl] morpholine ((S,S)/(R,R)-N-Boc-desethylRB), was prepared by the N-protection of (S,S)/(R,R)-2-[{alpha}-(2-hydroxyphenoxy)benzyl]morpholine ((S,S)/(R,R)-desethylRB) with a tert-butyloxycarbonyl (Boc) group followed by enantiomeric resolution with chiral HPLC to provide both (S,S) and (R,R) enantiomers with >99% enantiomeric purity. These compounds were then used for radiosynthesis to prepare enantiomerically pure [{sup 18}F]FRB and [{sup 18}F]FRB-D{sub 4} via the following three-step procedure: (1) formation of 1-bromo-2-[{sup 18}F]fluoroethane ([{sup 18}F]BFE or [{sup 18}F]BFE-D{sub 4}) by nucleophilic displacement of 2-bromoethyl triflate (or D{sub 4} analog) with no-carrier added [{sup 18}F]F{sup -} in THF; (2) reaction of [{sup 18}F]BFE (or [{sup 18}F]BFE-D{sub 4}) with N-Boc-desethylRB in DMF in the presence of excess base; and (3) deprotection with trifluoroacetic acid. The racemates, (S,S) and (R,R) enantiomers of [{sup 18}F]FRB and [{sup 18}F]FRB-D{sub 4} were obtained in 11-27% (decay corrected to the end of bombardment, EOB) in 120-min synthesis time with a radiochemical purity of >98% and specific activities of 21-48 GBq/{mu}mol (EOB). The results of the whole-body biodistribution studies with (S,S)-[{sup 18}F]FRB-D{sub 4} were similar to those with (S,S)-[{sup 18}F]FRB but showed relatively faster blood clearance and no significant in vivo defluorination. Positron emission tomography studies in baboon brain also

  6. Positron confinement in embedded lithium nanoclusters

    Science.gov (United States)

    van Huis, M. A.; van Veen, A.; Schut, H.; Falub, C. V.; Eijt, S. W.; Mijnarends, P. E.; Kuriplach, J.

    2002-02-01

    Quantum confinement of positrons in nanoclusters offers the opportunity to obtain detailed information on the electronic structure of nanoclusters by application of positron annihilation spectroscopy techniques. In this work, positron confinement is investigated in lithium nanoclusters embedded in monocrystalline MgO. These nanoclusters were created by means of ion implantation and subsequent annealing. It was found from the results of Doppler broadening positron beam analysis that approximately 92% of the implanted positrons annihilate in lithium nanoclusters rather than in the embedding MgO, while the local fraction of lithium at the implantation depth is only 1.3 at. %. The results of two-dimensional angular correlation of annihilation radiation confirm the presence of crystalline bulk lithium. The confinement of positrons is ascribed to the difference in positron affinity between lithium and MgO. The nanocluster acts as a potential well for positrons, where the depth of the potential well is equal to the difference in the positron affinities of lithium and MgO. These affinities were calculated using the linear muffin-tin orbital atomic sphere approximation method. This yields a positronic potential step at the MgO||Li interface of 1.8 eV using the generalized gradient approximation and 2.8 eV using the insulator model.

  7. Excessive sensitivity of momentum densities to crystal potentials as a reason for difficulties in verifying positron enhancement theories

    International Nuclear Information System (INIS)

    Sormann, H.

    2001-01-01

    The excessive sensitivity of the momentum densities of electron-positron annihilation pairs (MDAP) to crystal potentials found in this study severely deteriorates a possibility to use a comparison between theoretical and experimental MDAP results as a criterion for the legitimacy of electron-positron interaction theories. Illustrative examples are given. (orig.)

  8. Fermionic particles with positron-dependent mass in the presence of inversely quadratic Yukawa potential and tensor interaction

    International Nuclear Information System (INIS)

    Bahar, M.K.; Yasuk, F.

    2013-01-01

    Approximate solutions of the Dirac equation with positron-dependent mass are presented for the inversely quadratic Yukawa potential and Coulomb-like tensor interaction by using the asymptotic iteration method. The energy eigenvalues and the corresponding normalized eigenfunctions are obtained in the case of positron-dependent mass and arbitrary spin-orbit quantum number k state and approximation on the spin-orbit coupling term. (author)

  9. The two dynamical states in sinusoidal potentials: An analog simulation experiment

    Science.gov (United States)

    Sawkmie, Ivan Skhem; Mahato, Mangal C.

    2018-04-01

    The phenomenon of stochastic resonance (SR) is usually found to occur theoretically as well as experimentally in bi-stable systems [1]. Recently, it was numerically shown that SR is found to occur in underdamped (friction coefficient γ) sinusoidal potentials also. The occurrence of SR is explained in terms of two competing dynamical states of trajectories as a response to the external periodic drive. We setup an analog simulation experiment similar to the analog simulation work done earlier to study stochastic nonlinear dynamics [2], to verify the existence of the two dynamical states and to investigate the occurrence of SR in sinusoidal potentials obtained earlier [3]. We discuss our experimental setup and the results obtained in detail.

  10. AMIC: an expandable integrated analog front-end for light distribution moments analysis

    OpenAIRE

    SPAGGIARI, MICHELE; Herrero Bosch, Vicente; Lerche, Christoph Werner; Aliaga Varea, Ramón José; Monzó Ferrer, José María; Gadea Gironés, Rafael

    2011-01-01

    In this article we introduce AMIC (Analog Moments Integrated Circuit), a novel analog Application Specific Integrated Circuit (ASIC) front-end for Positron Emission Tomography (PET) applications. Its working principle is based on mathematical analysis of light distribution through moments calculation. Each moment provides useful information about light distribution, such as energy, position, depth of interaction, skewness (deformation due to border effect) etc. A current buffer delivers a cop...

  11. The proposed INEL intense slow positron source, beam line, and positron microscope facility

    International Nuclear Information System (INIS)

    Makowitz, H.; Denison, A.B.; Brown, B.

    1993-01-01

    A program is currently underway at the Idaho National Engineering Laboratory (INEL) to design and construct an Intense Slow Positron Beam Facility with an associated Positron Microscope. Positron beams have been shown to be valuable research tools and have potential application in industrial processing and nondestructive evaluation (microelectronics, etc.). The limit of resolution or overall usefulness of the technique has been limited because of lack of sufficient intensity. The goal of the INEL positron beam is ≥ 10 12 slow e+/s over a 0.03 cm diameter which represents a 10 3 to 10 4 advancement in beam current over existing beam facilities. The INEL is an ideal site for such a facility because of the nuclear reactors capable of producing intense positron sources and the personnel and facilities capable of handling high levels of radioactivity. A design using 58 Co with moderators and remoderators in conjunction with electrostatic positron beam optics has been reached after numerous computer code studies. Proof-of-principle electron tests have demonstrated the feasibility of the large area source focusing optics. The positron microscope development is occurring in conjunction with the University of Michigan positron microscope group. Such a Beam Facility and associated Intense Slow Positron Source (ISPS) can also be utilized for the generation and study of positron, and positron electron plasmas at ≤ 10 14 particles/cm 3 with plasma temperatures ranging from an eV to many keV, as well as an intense x-ray source via positron channeling radiation. The possibility of a tunable x-ray laser based on channeling positron radiation also exists. In this discussion the authors will present a progress report on various activities associated with the INEL ISPS

  12. Syntheses and biological activities of novel 2-methoxyestradiol analogs, 2-fluoroethoxyestradiol and 2-fluoropropanoxyestradiol, and a radiosynthesis of 2-[18F]fluoroethoxyestradiol for positron emission tomography

    International Nuclear Information System (INIS)

    Mun Jiyoung; Wang Yuefang; Voll, Ronald J.; Escuin-Borras, Daniel; Giannakakou, Paraskevi; Goodman, Mark M.

    2008-01-01

    Introduction: 2-Methoxyestradiol (2ME2) is an endogenous metabolite of the human hormone, estrogen, which has been shown to possess anti-tumor activity. 2-Fluoroethoxyestradiol (2FEE2) and 2-fluoropropanoxyestradiol (2FPE2), novel analogs of 2-methoxyestradiol, were designed and synthesized to be utilized as F-18 radiotracers for positron emission tomography (PET), with which the bio-distribution and intratumoral accumulations of 2ME2 could be measured in vivo for potential translation to human use. Methods: 2FEE2 and 2FPE2 were synthesized from 3,17β-estradiol in five steps respectively. Drug-induced microtubule depolymerization, antiproliferative activity against human cancer cell lines and HIF-1α down-regulation by 2FEE2 and 2FPE2 were investigated to examine whether these molecules possess similar anti-tumor activities as 2-methoxyestradiol. 2-[ 18 F]Fluoroethoxyestradiol was synthesized for PET. Results: Novel 2ME2 analogs, 2FEE2 and 2FPE2, were synthesized in 29% and 22% overall yield, respectively. 2FEE2 and 2FPE2 showed microtubule depolymerization and cytotoxicities against the human ovarian carcinoma cell line, 1A9, and the human glioma cell line, LN229. HIF-1α was down-regulated by 2FEE2 and 2FPE2 under hypoxic conditions. 2FEE2 was chosen as an F-18 radiotracer candidate, since it showed stronger antiproliferative activity than 2ME2 and 2FPE2. 2-[ 18 F]Fluoroethoxyestradiol (2[ 18 F]FEE2) was prepared in 8.3% decay-corrected yield in 90 min, based on a production of H[ 18 F]F with more than 98% radiochemical purity. Conclusions: 2FEE2 and 2FPE2 showed similar activity as 2ME2. 2[ 18 F]FEE2 was synthesized to be utilized as a PET radiotracer to measure the biological efficacy of 2ME2 and its analogs in vivo

  13. Positron astrophysics and areas of relation to low-energy positron physics

    International Nuclear Information System (INIS)

    Guessoum, N.

    2014-01-01

    I briefly review our general knowledge of positron astrophysics, focusing mostly on the theoretical and modelling aspects. The experimental/observational aspects of the topic have recently been reviewed elsewhere [E. Churazov et al., Mon. Nat. R. Astron. Soc. 411, 1727 (2011); N. Prantazos et al., Rev. Mod. Phys. 83, 1001 (2011)]. In particular, I highlight the interactions and cross sections of the reactions that the positrons undergo in various cosmic media. Indeed, these must be of high interest to both the positron astrophysics community and the low-energy positron physics community in trying to find common areas of potential collaboration for the future or areas of research that will help the astrophysics community make further progress on the problem. The processes undergone by positrons from the moments of their birth to their annihilation (in the interstellar medium or other locations) are thus examined. The physics of the positron interactions with gases and solids (dust grains) and the physical conditions and characteristics of the environments where the processes of energy loss, positronium formation, and annihilation take place, are briefly reviewed. An explanation is given about how all the relevant physical information is taken into account in order to calculate annihilation rates and spectra of the 511 keV emission in the ISM; special attention is paid to positron interactions with dust and with polycyclic aromatic hydrocarbons. In particular, an attempt is made to show to what extent the interactions between positrons and interstellar dust grains are similar to laboratory experiments in which beams of low-energy positrons impinge upon solids and surfaces. Sample results are shown for the effect of dust grains on positron annihilation spectra in some phases of the ISM which, together with high resolution spectra measured by satellites, can be used to infer useful knowledge about the environment where the annihilation is predominantly taking place

  14. Puzzling with potential: dynamic testing of analogical reasoning in children

    OpenAIRE

    Stevenson, Claire Elisabeth

    2012-01-01

    Assessment procedures are frequent in children's school careers; however, measuring potential for learning has remained a puzzle. Dynamic testing is a method to assess cognitive potential that includes training in the assessment process. The goal of this thesis project was to develop a new dynamic test of analogical reasoning for school children. The main aims were to (1) investigate factors that influence children’s differences in performance and change during dynamic testing and (2) examine...

  15. Positron astrophysics and areas of relation to low-energy positron physics

    Science.gov (United States)

    Guessoum, Nidhal

    2014-05-01

    I briefly review our general knowledge of positron astrophysics, focusing mostly on the theoretical and modelling aspects. The experimental/observational aspects of the topic have recently been reviewed elsewhere [E. Churazov et al., Mon. Nat. R. Astron. Soc. 411, 1727 (2011); N. Prantazos et al., Rev. Mod. Phys. 83, 1001 (2011)]. In particular, I highlight the interactions and cross sections of the reactions that the positrons undergo in various cosmic media. Indeed, these must be of high interest to both the positron astrophysics community and the low-energy positron physics community in trying to find common areas of potential collaboration for the future or areas of research that will help the astrophysics community make further progress on the problem. The processes undergone by positrons from the moments of their birth to their annihilation (in the interstellar medium or other locations) are thus examined. The physics of the positron interactions with gases and solids (dust grains) and the physical conditions and characteristics of the environments where the processes of energy loss, positronium formation, and annihilation take place, are briefly reviewed. An explanation is given about how all the relevant physical information is taken into account in order to calculate annihilation rates and spectra of the 511 keV emission in the ISM; special attention is paid to positron interactions with dust and with polycyclic aromatic hydrocarbons. In particular, an attempt is made to show to what extent the interactions between positrons and interstellar dust grains are similar to laboratory experiments in which beams of low-energy positrons impinge upon solids and surfaces. Sample results are shown for the effect of dust grains on positron annihilation spectra in some phases of the ISM which, together with high resolution spectra measured by satellites, can be used to infer useful knowledge about the environment where the annihilation is predominantly taking place

  16. C-11-labeled octadecylamine, a potential agent for positron tomographic pulmonary metabolism studies

    International Nuclear Information System (INIS)

    Washburn, L.C.; Wallace, R.T.; Byrd, B.L.; Sun, T.T.; Coffey, J.L.; Hubner, K.F.

    1984-01-01

    C-11-Labeled straight-chain primary aliphatic amines are rapidly and selectively sequestered by lung endothelial cells, making these agents potentially useful for positron tomographic studies of the lung as a metabolic organ. However, because amines having straight chains containing 4 to 13 carbon atoms are rapidly catabolized in vivo with loss of radiolabel, quantitation of pulmonary concentration is difficult. The authors have studied the effect of structural changes on the uptake and retention of primary aliphatic amines in rat lung and found that the metabolic loss form the lung decreased with increasing length of the straight carbon chain. In fact, the lung concentration of octadecylamine, a straight-chain amine with 18 carbon atoms, was constant between 1 and 30 minutes after intravenous administration. This highly insoluble amine was solubilized using 3% aqueous human serum albumin. Unilateral, radiation-induced lung injury in the rat was used as a model to study the potential of C-11-labeled octadecylamine. Radiation-damaged (3000 and 5000 Rads) lungs had significantly lower 15-minute uptakes of the labeled amine than the corresponding nonirradiated lungs. However, at 8000 Rads the concentration in both lungs was greatly suppressed, indicating that the decrease in metabolism becomes systemic at high radiation doses. These results suggest that C-11-labeled octadecylamine is a potentially useful agent for quantitative evaluation of pulmonary metabolism by positron tomography

  17. Characterization of lacunar defects by positrons annihilation

    CERN Document Server

    Barthe, M F; Blondiaux, G

    2003-01-01

    Among the nondestructive methods for the study of matter, the positrons annihilation method allows to sound the electronic structure of materials by measuring the annihilation characteristics. These characteristics depend on the electronic density as seen by the positon, and on the electron momentums distribution which annihilate with the positon. The positon is sensible to the coulombian potential variations inside a material and sounds preferentially the regions away from nuclei which represent potential wells. The lacunar-type defects (lack of nuclei) represent deep potential wells which can trap the positon up to temperatures close to the melting. This article describes the principles of this method and its application to the characterization of lacunar defects: 1 - positrons: matter probes (annihilation of electron-positon pairs, annihilation characteristics, positrons sources); 2 - positrons interactions in solids (implantation profiles, annihilation states, diffusion and trapping, positon lifetime spec...

  18. Descriptions of positron defect analysis capabilities

    International Nuclear Information System (INIS)

    Howell, R.H.

    1994-10-01

    A series of descriptive papers and graphics appropriate for distribution to potential collaborators has been assembled. These describe the capabilities for defect analysis using positron annihilation spectroscopy. The application of positrons to problems in the polymer and semiconductor industries is addressed

  19. High intensity positron program at LLNL

    International Nuclear Information System (INIS)

    Asoka-Kumar, P.; Howell, R.; Stoeffl, W.; Carter, D.

    1999-01-01

    Lawrence Livermore National Laboratory (LLNL) is the home of the world's highest current beam of keV positrons. The potential for establishing a national center for materials analysis using positron annihilation techniques around this capability is being actively pursued. The high LLNL beam current will enable investigations in several new areas. We are developing a positron microprobe that will produce a pulsed, focused positron beam for 3-dimensional scans of defect size and concentration with submicron resolution. Below we summarize the important design features of this microprobe. Several experimental end stations will be available that can utilize the high current beam with a time distribution determined by the electron linac pulse structure, quasi-continuous, or bunched at 20 MHz, and can operate in an electrostatic or (and) magnetostatic environment. Some of the planned early experiments are: two-dimensional angular correlation of annihilation radiation of thin films and buried interfaces, positron diffraction holography, positron induced desorption, and positron induced Auger spectroscopy

  20. High intensity positron program at LLNL

    International Nuclear Information System (INIS)

    Asoka-Kumar, P.; Howell, R.H.; Stoeffl, W.

    1998-01-01

    Lawrence Livermore National Laboratory (LLNL) is the home of the world's highest current beam of keV positrons. The potential for establishing a national center for materials analysis using positron annihilation techniques around this capability is being actively pursued. The high LLNL beam current will enable investigations in several new areas. We are developing a positron microprobe that will produce a pulsed, focused positron beam for 3-dimensional scans of defect size and concentration with submicron resolution. Below we summarize the important design features of this microprobe. Several experimental end stations will be available that can utilize the high current beam with a time distribution determined by the electron linac pulse structure, quasi-continuous, or bunched at 20 MHz, and can operate in an electrostatic or (and) magnetostatic environment. Some of the planned early experiments are: two-dimensional angular correlation of annihilation radiation of thin films and buried interfaces, positron diffraction holography, positron induced desorption, and positron induced Auger spectra

  1. Positron-attachment to small molecules: Vibrational enhancement of positron affinities with configuration interaction level of multi-component molecular orbital approach

    Energy Technology Data Exchange (ETDEWEB)

    Tachikawa, Masanori [Quantum Chemistry Division, Graduate School of NanoBioScience, Yokohama City University, 22-2 Seto, Kanazawa, Yokohama 236-0027 (Japan)

    2015-12-31

    To theoretically demonstrate the binding of a positron to small polarized molecules, we have calculated the vibrational averaged positron affinity (PA) values along the local vibrational contribution with the configuration interaction level of multi-component molecular orbital method. This method can take the electron-positron correlation contribution into account through single electronic - single positronic excitation configurations. The PA values are enhanced by including the local vibrational contribution from vertical PA values due to the anharmonicity of the potential.

  2. High intensity positron program at LLNL

    International Nuclear Information System (INIS)

    Asoka-Kumar, P.; Howell, R.; Stoeffl, W.; Carter, D.

    1999-01-01

    Lawrence Livermore National Laboratory (LLNL) is the home of the world close-quote s highest current beam of keV positrons. The potential for establishing a national center for materials analysis using positron annihilation techniques around this capability is being actively pursued. The high LLNL beam current will enable investigations in several new areas. We are developing a positron microprobe that will produce a pulsed, focused positron beam for 3-dimensional scans of defect size and concentration with submicron resolution. Below we summarize the important design features of this microprobe. Several experimental end stations will be available that can utilize the high current beam with a time distribution determined by the electron linac pulse structure, quasi-continuous, or bunched at 20 MHz, and can operate in an electrostatic or (and) magnetostatic environment. Some of the planned early experiments are: two-dimensional angular correlation of annihilation radiation of thin films and buried interfaces, positron diffraction holography, positron induced desorption, and positron induced Auger spectroscopy. copyright 1999 American Institute of Physics

  3. Studies towards the synthesis of ATP analogs as potential glutamine synthetase inhibitors

    CSIR Research Space (South Africa)

    Salisu, S

    2011-05-01

    Full Text Available and Centre for Chemico- and Biomedicinal Research, Rhodes University, Grahamstown, South Africa b CSIR BIO/CHEMTEK, Modderfontein, South Africa ABSTRACT In research directed at the development of adenine triphosphate (ATP) analogs as potential...

  4. Cosmic Ray Positrons from Pulsars

    Science.gov (United States)

    Harding, Alice K.

    2010-01-01

    Pulsars are potential Galactic sources of positrons through pair cascades in their magnetospheres. There are, however, many uncertainties in establishing their contribution to the local primary positron flux. Among these are the local density of pulsars, the cascade pair multiplicities that determine the injection rate of positrons from the pulsar, the acceleration of the injected particles by the pulsar wind termination shock, their rate of escape from the pulsar wind nebula, and their propagation through the interstellar medium. I will discuss these issues in the context of what we are learning from the new Fermi pulsar detections and discoveries.

  5. Application of positron annihilation to polymer and development of a radioisotopes-based pulsed slow positron beam apparatus

    International Nuclear Information System (INIS)

    Suzuki, Takenori

    2004-01-01

    Positrons injected into polymer behave as nanometer probes, which can detect the size and amount of intermolecular spaces among polymer structures. Although positrons can probe the characteristics of polymer, they induce a radiation effect on polymer samples. At low temperature, the radiation effect induces free electrons, which can be trapped in a shallow potential created among intermolecular structures after freezing molecular motions. These trapped electrons can be released after the disappearance of the shallow potential due to the reappearance of molecular motion above the relaxation temperature. Thus, positrons can be used as a probe for relaxation studies. Coincidence of Doppler broadening spectroscopy (CDBS) can improve the S/N ratio to 10 7 , which makes it possible to detect trace elements, since CDBS can separate the high-momentum component of core electrons. A pulsed slow positron beam apparatus is necessary for measuring holes in the polymer film and allows the measurement of the characteristics of thin film coated on semiconductors used widely in electronics industries. (author)

  6. Electrostatic solitons in unmagnetized hot electron-positron-ion plasmas

    International Nuclear Information System (INIS)

    Mahmood, S.; Ur-Rehman, H.

    2009-01-01

    Linear and nonlinear electrostatic waves in unmagnetized electron-positron-ion (e-p-i) plasmas are studied. The electrons and positrons are assumed to be isothermal and dynamic while ions are considered to be stationary to neutralize the plasma background only. It is found that both upper (fast) and lower (slow) Langmuir waves can propagates in such a type of pair (e-p) plasma in the presence of ions. The small amplitude electrostatic Korteweg-de Vries (KdV) solitons are also obtained using reductive perturbation method. The electrostatic potential hump structures are found to exist when the temperature of the electrons is larger than the positrons, while the electrostatic potential dips are obtained in the reverse temperature conditions for electrons and positrons in e-p-i plasmas. The numerical results are also shown for illustration. The effects of different ion concentration and temperature ratios of electrons and positrons, on the formation of nonlinear electrostatic potential structures in e-p-i plasmas are also discussed.

  7. Electron and positron atomic elastic scattering cross sections

    International Nuclear Information System (INIS)

    Stepanek, Jiri

    2003-01-01

    A method was developed to calculate the total and differential elastic-scattering cross sections for incident electrons and positrons in the energy range from 0.01 eV to 1 MeV for atoms of Z=1-100. For electrons, hydrogen, helium, nitrogen, oxygen, krypton, and xenon, and for positrons, helium, neon, and argon atoms were considered for comparison with experimental data. First, the variationally optimized atomic static potentials were calculated for each atom by solving the Dirac equations for bound electron states. Second, the Dirac equations for a free electron or positron are solved for an atom using the previously calculated static potential accomplished (in the case of electrons) by 'adjusted' Hara's exchange potential for a free-state particle. Additional to the exchange effects, the charge cloud polarization effects are considered applying the correlation-polarization potential of O'Connell and Lane (with correction of Padial and Norcross) for incident electrons, and of Jain for incident positrons. The total, cutoff and differential elastic-scattering cross sections are calculated for incident electrons and positrons with the help of the relativistic partial wave analysis. The solid state effects for scattering in solids are described by means of a muffin-tin model, i.e. the potentials of neighboring atoms are superpositioned in such a way that the resulting potential and its derivative are zero in the middle distance between the atoms. The potential of isolated atom is calculated up to the radius at which the long-range polarization potential becomes a value of -10 -8

  8. Positron-molecule interactions and corresponding positron attachment to molecules. As a basis for positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Tachikawa, Masanori; Kimura, Mineo; Pichl, Lukas

    2007-01-01

    Through positron and electron interactions, they annihilate emitting primarily two gamma rays with 180-degree opposite directions. Positron spectroscopy using the characteristics of these gamma rays has been employed for analyzing various properties of material as well as for positron emission tomography (PET). However, its fundamental physics of positron-electron interactions and resulting features of emitting gamma rays are not well understood. By obtaining better understanding of positron interactions, it should become possible to provide the firm bases for positron spectroscopy in finer accuracy and quality. Here, we propose a significant mechanism for positron annihilation through positron attachment process, which may help increase the quality of positron spectroscopy. (author)

  9. Detecting analogical resemblance without retrieving the source analogy.

    Science.gov (United States)

    Kostic, Bogdan; Cleary, Anne M; Severin, Kaye; Miller, Samuel W

    2010-06-01

    We examined whether people can detect analogical resemblance to an earlier experimental episode without being able to recall the experimental source of the analogical resemblance. We used four-word analogies (e.g., robin-nest/beaver-dam), in a variation of the recognition-without-cued-recall method (Cleary, 2004). Participants studied word pairs (e.g., robin-nest) and were shown new word pairs at test, half of which analogically related to studied word pairs (e.g., beaver-dam) and half of which did not. For each test pair, participants first attempted to recall an analogically similar pair from the study list. Then, regardless of whether successful recall occurred, participants were prompted to rate the familiarity of the test pair, which was said to indicate the likelihood that a pair that was analogically similar to the test pair had been studied. Across three experiments, participants demonstrated an ability to detect analogical resemblance without recalling the source analogy. Findings are discussed in terms of their potential relevance to the study of analogical reasoning and insight, as well as to the study of familiarity and recognition memory.

  10. Electron-positron annihilation at high luminosity colliding beams

    International Nuclear Information System (INIS)

    Grigoryan, G.V.; Khodzhamiryan, A.Yu.

    1977-01-01

    Experiments are discussed, which can be carried out at the electron-positron storage rings with increased luminosity (up to 10 34 cm -2 sec -1 ) and corresponding improvement of detectors at total energy region up to 10 GeV. This improvement of the experimental conditions may provide valuable physical information from the theoretical point of view. The comparison is made with analogous experimental possibilities of the projected high energy e + e - storage rings with luminosity up to 10 32 cm -2 sec -1

  11. Detection of tokamak plasma positrons using annihilation photons

    Energy Technology Data Exchange (ETDEWEB)

    Guanying, Yu; Liu, Jian; Xie, Jinlin [University of Science and Technology, Hefei, Anhui, 230027 (China); Li, Jiangang, E-mail: j_li@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China)

    2017-05-15

    Highlights: • A design for detection of tokamak plasma positrons is given. • Identify the main obstacle toward experimental confirmation of fusion plasma positrons. • Signal to noise ratio in a plasma disruption is estimated. • Unique potential applications of fusion plasma positrons are discussed. - Abstract: A massive amount of positrons (plasma positrons), produced by the collision between runaway electrons and nuclei during fusion plasma disruption, was first predicted theoretically in 2003. To help confirm this prediction, we report here the design of an experimental system to detect tokamak plasma positrons. Because a substantial amount of positrons (material positrons) are produced when runaway electrons impact plasma-facing materials, we proposed maximizing the ratio of plasma to material positrons by inserting a thin carbon target at the plasma edge as a plasma positron bombing target and producing a plasma disruption scenario triggered by massive gas injection. Meanwhile, the coincidence detection of positron annihilation photons was used to filter out the noise of annihilation photons from locations other than the carbon target and that of bremsstrahlung photons near 511 keV. According to our simulation, the overall signal-to-noise ratio should be more than 10:1.

  12. Ultrarelativistic electron and positron radiation in planar channeling

    International Nuclear Information System (INIS)

    Kalashnikov, N.P.; Olchack, A.S.

    1980-01-01

    The coherent electromagnetic radiation from channeling electrons and positrons is given by similar expression. However for the channeling positrons the close collisions are suppressed due to the fact that the positron wave function is exponentially small near the atoms of the crystal lattice. It follows that the coherent bremsstrahlung decreases for the channeling positrons. We have investigated the ultrarelativistic channeling electron and positron radiations, connected with the electromagnetic transitions from the continuum spectrum states to the quasi-bound spectrum states and between the different quasi-bound spectrum states. The radiation probabilities are calculated by using the model continuum planar potential. It is shown that the radiation from the channeling electrons is several orders of magnitude larger than the positron radiation, while the electron and positron radiation have similar characteristics such as frequency limitation and angular distribution of the radiation. (orig.)

  13. Synthesis and biological evaluation of ¹⁸F-labeled fluoropropyl tryptophan analogs as potential PET probes for tumor imaging.

    Science.gov (United States)

    Chiotellis, Aristeidis; Mu, Linjing; Müller, Adrienne; Selivanova, Svetlana V; Keller, Claudia; Schibli, Roger; Krämer, Stefanie D; Ametamey, Simon M

    2013-01-01

    In the search for an efficient, fluorine-18 labeled amino acid based radiotracer for tumor imaging with positron emission tomography (PET), two new tryptophan analogs were synthesized and characterized in vitro and in vivo. Both are tryptophan alkyl-derivatives, namely 2-(3-[(18)F]fluoropropyl)-DL-tryptophan ([(18)F]2-FPTRP) and 5-(3-[(18)F]fluoro-propyl)-DL-tryptophan ([(18)F]5-FPTRP). Standard reference compounds and precursors were prepared by multi step approaches. Radiosynthesis was achieved by no-carrier-added nucleophilic [(18)F]fluorination in 29-34% decay corrected yields with radiochemical purity over 99%. In vitro cell uptake assays showed that both compounds are substrates for amino acid transport and enter small cell lung cancer cells (NCI-H69) most probably almost exclusively via large neutral amino acids transporter(s) (LAT). Small animal PET imaging with xenograft bearing mice revealed high tumor/background ratios for [(18)F]2-FPTRP comparable to the well established tyrosine analog O-(2-[(18)F]fluroethyl)-L-tyrosine ([(18)F]FET). Radiometabolite studies showed no evidence of involvement of a biotransformation step in tumor accumulation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  14. Development of slow positron beam lines and applications

    Science.gov (United States)

    Mondal, Nagendra Nath

    2018-05-01

    A positron is an antiparticle of an electron that can be formed in diverse methods: natural or artificial β-decay process, fission and fusion reactions, and a pair production of electron-positron occurred in the reactor and the high energy accelerator centers. Usually a long-lifetime radio isotope is customized for the construction of a slow positron beam lines in many laboratories. The typical intensity of this beam depends upon the strength of the positron source, moderator efficiency, and guiding, pulsing, focusing and detecting systems. This article will review a few positron beam lines and their potential applications in research, especially in the Positronium Bose-Einstein Condensation.

  15. Fluorodeoxyglucose-based positron emission tomography imaging to monitor drug responses in hematological tumors

    NARCIS (Netherlands)

    Newbold, Andrea; Martin, Ben P.; Cullinane, Carleen; Bots, Michael

    2014-01-01

    Positron emission tomography (PET) can be used to monitor the uptake of the labeled glucose analog fluorodeoxyglucose (¹⁸F-FDG), a process that is generally believed to reflect viable tumor cell mass. The use of ¹⁸F-FDG PET can be helpful in documenting over time the reduction in tumor mass volume

  16. Analog earthquakes

    International Nuclear Information System (INIS)

    Hofmann, R.B.

    1995-01-01

    Analogs are used to understand complex or poorly understood phenomena for which little data may be available at the actual repository site. Earthquakes are complex phenomena, and they can have a large number of effects on the natural system, as well as on engineered structures. Instrumental data close to the source of large earthquakes are rarely obtained. The rare events for which measurements are available may be used, with modfications, as analogs for potential large earthquakes at sites where no earthquake data are available. In the following, several examples of nuclear reactor and liquified natural gas facility siting are discussed. A potential use of analog earthquakes is proposed for a high-level nuclear waste (HLW) repository

  17. A combined matrix isolation spectroscopy and cryosolid positron moderation apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Molek, Christopher D.; Michael Lindsay, C.; Fajardo, Mario E. [Air Force Research Laboratory, Munitions Directorate, Ordnance Division, Energetic Materials Branch, AFRL/RWME, 2306 Perimeter Road, Eglin AFB, Florida 32542-5910 (United States)

    2013-03-15

    We describe the design, construction, and operation of a novel apparatus for investigating efficiency improvements in thin-film cryogenic solid positron moderators. We report results from solid neon, argon, krypton, and xenon positron moderators which illustrate the capabilities and limitations of our apparatus. We integrate a matrix isolation spectroscopy diagnostic within a reflection-geometry positron moderation system. We report the optical thickness, impurity content, and impurity trapping site structures within our moderators determined from infrared absorption spectra. We use a retarding potential analyzer to modulate the flow of slow positrons, and report positron currents vs. retarding potential for the different moderators. We identify vacuum ultraviolet emissions from irradiated Ne moderators as the source of spurious signals in our channel electron multiplier slow positron detection channel. Our design is also unusual in that it employs a sealed radioactive Na-22 positron source which can be translated relative to, and isolated from, the cryogenic moderator deposition substrate. This allows us to separate the influences on moderator efficiency of surface contamination by residual gases from those of accumulated radiation damage.

  18. Bosonic analog of the Klein paradox

    International Nuclear Information System (INIS)

    Wagner, R. E.; Ware, M. R.; Su, Q.; Grobe, R.

    2010-01-01

    The standard Klein paradox describes how an incoming electron scatters off a supercritical electrostatic barrier that is so strong that it can generate electron-positron pairs. This fermionic system has been widely discussed in textbooks to illustrate some of the discrepancies between quantum mechanical and quantum field theoretical descriptions for the pair creation process. We compare the fermionic dynamics with that of the corresponding bosonic system. We point out that the direct counterpart of the Pauli exclusion principle (the central mechanism to resolve the fermionic Klein paradox) is stimulated emission, which leads to the resolution of the analogous bosonic paradox.

  19. Methods and instrumentation for positron emission tomography

    International Nuclear Information System (INIS)

    Mandelkern, M.A.; Phelps, M.E.

    1988-01-01

    This paper reports on positron emission tomography (PET), a technique for the noninvasive measurement of local tissue concentrations of injected radioactive tracers. Tracer kinetics techniques can be applied to this information to quantify physiologic function in human tissue. In the tracer method, a pharmaceutical is labeled by a radioactive atom. When introduced into the subject that molecule follows a physiologic pathway. The space- and time-dependent distribution of the radionuclide is obtained via an imaging technique. If the radiopharmaceutical is sufficiently analogous to a natural substrate or other substance of interest, a quantitative image can be translated into a physiologic measurement

  20. Planned Positron Factory project

    International Nuclear Information System (INIS)

    Okada, Sohei

    1990-01-01

    The Japan Atomic Energy Research Institute, JAERI, has started, drafting a construction plan for the 'Positron Factory', in which intense energy-controllable monoenergetic positron beams are produced from pair-production reactions caused by high-energy electrons from a linac. The JAERI organized a planning committee to provide a basic picture for the Positron Factory. This article presents an overview of the interactions of positrons, intense positron sources and the research program and facilities planned for the project. The interactions of positrons and intense positron sources are discussed focusing on major characteristics of positrons in different energy ranges. The research program for the Positron Factory is then outlined, focusing on advanced positron annihilation techniques, positron spectroscopy (diffraction, scattering, channeling, microscopy), basic positron physics (exotic particle science), and positron beam technology. Discussion is also made of facilities required for the Positron Factory. (N.K.)

  1. Alternative positron emission tomography with non-conventional positron emitters: effects of their physical properties on image quality and potential clinical applications

    International Nuclear Information System (INIS)

    Pagani, M.; Stone-Elander, S.; Larsson, S.A.

    1997-01-01

    The increasing amount of clinically relevant information obtained by positron emission tomography (PET), primarily with fluorine-18 labelled 2-deoxy-2-fluoro-d-glucose, has generated a demand for new routes for the widespread and cost-efficient use of positron-emitting radiopharmaceuticals. New dual-head single-photon emission tomography (SPET) cameras are being developed which offer coincidence detection with camera heads lacking a collimator or SPET imaging with specially designed collimators and additional photon shielding. Thus, not only satellite PET imaging units but also nuclear medicine units investing in these new SPET/PET systems need to examine all available alternatives for rational radionuclide supplies from host cyclotrons. This article examines 25 ''alternative'' positron-emitting radionuclides, discusses the impact of their decay properties on image quality and reviews methods for their production as well as for their application in imaging techniques. (orig.)

  2. Positron sources

    International Nuclear Information System (INIS)

    Chehab, R.

    1989-01-01

    A tentative survey of positron sources is given. Physical processes on which positron generation is based are indicated and analyzed. Explanation of the general features of electromagnetic interactions and nuclear β + decay makes it possible to predict the yield and emittance for a given optical matching system between the positron source and the accelerator. Some kinds of matching systems commonly used - mainly working with solenoidal fields - are studied and the acceptance volume calculated. Such knowledge is helpful in comparing different matching systems. Since for large machines, a significant distance exists between the positron source and the experimental facility, positron emittance has to be preserved during beam transfer over large distances and methods used for that purpose are indicated. Comparison of existing positron sources leads to extrapolation to sources for future linear colliders

  3. Positron-acoustic waves in an electron-positron plasma with an electron beam

    International Nuclear Information System (INIS)

    Nejoh, Y.N.

    1996-01-01

    The nonlinear wave structures of large-amplitude positron-acoustic waves are studied in an electron-positron plasma in the presence of an electron beam with finite temperature and hot electrons and positrons. The region where positron-acoustic waves exist is presented by analysing the structure of the pseudopotential. The region depends sensitively on the positron density, the positron temperature and the electron beam temperature. It is shown that the maximum amplitude of the wave decreases as the positron temperature increases, and the region of positron-acoustic waves spreads as the positron temperature increases. 11 refs., 5 figs

  4. New Possibilities of Positron-Emission Tomography

    Science.gov (United States)

    Volobuev, A. N.

    2018-01-01

    The reasons for the emergence of the angular distribution of photons generated as a result of annihilation of an electron and a positron in a positron-emission tomograph are investigated. It is shown that the angular distribution of the radiation intensity (i.e., the probability of photon emission at different angles) is a consequence of the Doppler effect in the center-of-mass reference system of the electron and the positron. In the reference frame attached to the electron, the angular distribution of the number of emitted photons does not exists but is replaced by the Doppler shift of the frequency of photons. The results obtained in this study make it possible to extend the potentialities of the positron-emission tomograph in the diagnostics of diseases and to obtain additional mechanical characteristics of human tissues, such as density and viscosity.

  5. Characterization of lacunar defects by positrons annihilation

    International Nuclear Information System (INIS)

    Barthe, M.F.; Corbel, C.; Blondiaux, G.

    2003-01-01

    Among the nondestructive methods for the study of matter, the positrons annihilation method allows to sound the electronic structure of materials by measuring the annihilation characteristics. These characteristics depend on the electronic density as seen by the positon, and on the electron momentums distribution which annihilate with the positon. The positon is sensible to the coulombian potential variations inside a material and sounds preferentially the regions away from nuclei which represent potential wells. The lacunar-type defects (lack of nuclei) represent deep potential wells which can trap the positon up to temperatures close to the melting. This article describes the principles of this method and its application to the characterization of lacunar defects: 1 - positrons: matter probes (annihilation of electron-positon pairs, annihilation characteristics, positrons sources); 2 - positrons interactions in solids (implantation profiles, annihilation states, diffusion and trapping, positon lifetime spectrum: evolution with the concentration of defects); 3 - measurement of annihilation characteristics with two gamma photons (lifetime spectroscopy with the β + 22 Na isotope, spectroscopy of Doppler enlargement of the annihilation line); 4 - determination of the free volume of defects inside or at the surface of materials (annihilation signature in lacunar defects, lacuna, lacunar clusters and cavities, acceptors nature in semiconductors: ionic or lacunar, interface defects, precipitates in alloys); 5 - conclusions. (J.S.)

  6. Positron sources

    International Nuclear Information System (INIS)

    Chehab, R.

    1994-01-01

    A tentative survey of positron sources is given. Physical processes on which positron generation is based are indicated and analyzed. Explanation of the general features of electromagnetic interactions and nuclear β + decay makes it possible to predict the yield and emittance for a given optical matching system between the positron source and the accelerator. Some kinds of matching systems commonly used - mainly working with solenoidal field - are studied and the acceptance volume calculated. Such knowledge is helpful in comparing different matching systems. Since for large machines, a significant distance exists between the positron source and the experimental facility, positron emittance has to be preserved during beam transfer over large distances and methods used for that purpose are indicated. Comparison of existing positron sources leads to extrapolation to sources for future linear colliders. Some new ideas associated with these sources are also presented. (orig.)

  7. Transmission positron microscopes

    International Nuclear Information System (INIS)

    Doyama, Masao; Kogure, Yoshiaki; Inoue, Miyoshi; Kurihara, Toshikazu; Yoshiie, Toshimasa; Oshima, Ryuichiro; Matsuya, Miyuki

    2006-01-01

    Immediate and near-future plans for transmission positron microscopes being built at KEK, Tsukuba, Japan, are described. The characteristic feature of this project is remolding a commercial electron microscope to a positron microscope. A point source of electrons kept at a negative high voltage is changed to a point source of positrons kept at a high positive voltage. Positional resolution of transmission microscopes should be theoretically the same as electron microscopes. Positron microscopes utilizing trapping of positrons have always positional ambiguity due to the diffusion of positrons

  8. Positron annihilation study in La2CuO4

    International Nuclear Information System (INIS)

    Kubo, Y.; Asano, S.

    1992-01-01

    The positron annihilation study for La 2 CuO 4 are performed using the full-potential linearized augmented-plane-wave(FLAPW) calculated electron and positron densities. The electron-positron momentum density(EPMD) is computed, and the well known Lock-Crisp-West(LCW) zone folding of the EPMD is produced. In the LCW analysis, small residual variations of order about 3 % are observed. The calculations show that the relative weights of the Fermi surface discontinuities are substantially altered due to the positron preferentially sampling the Cu-O plane region

  9. Undulator-based production of polarized positrons

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, G. [Tel-Aviv Univ. (Israel); Barley, J. [Cornell Univ., Ithaca, NY (United States); Batygin, Y. [SLAC, Menlo Park, CA (US)] (and others)

    2009-05-15

    Full exploitation of the physics potential of a future International Linear Collider will require the use of polarized electron and positron beams. Experiment E166 at the Stanford Linear Accelerator Center (SLAC) has demonstrated a scheme in which an electron beam passes through a helical undulator to generate photons (whose first-harmonic spectrum extended to 7.9 MeV) with circular polarization, which are then converted in a thin target to generate longitudinally polarized positrons and electrons. The experiment was carried out with a one-meter-long, 400-period, pulsed helical undulator in the Final Focus Test Beam (FFTB) operated at 46.6 GeV. Measurements of the positron polarization have been performed at five positron energies from 4.5 to 7.5 MeV. In addition, the electron polarization has been determined at 6.7MeV, and the effect of operating the undulator with a ferrofluid was also investigated. To compare the measurements with expectations, detailed simulations were made with an upgraded version of GEANT4 that includes the dominant polarization-dependent interactions of electrons, positrons, and photons with matter. The measurements agree with calculations, corresponding to 80% polarization for positrons near 6 MeV and 90% for electrons near 7 MeV. (orig.)

  10. Recent developments in positron emission tomography (PET) instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Derenzo, S.E.; Budinger, T.F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors. 117 refs., 4 figs., 4 tabs.

  11. Recent developments in positron emission tomography (PET) instrumentation

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors. 117 refs., 4 figs., 4 tabs

  12. Mutagenic activity of a fluorinated analog of the beta-adrenoceptor ligand carazolol in the Ames test

    NARCIS (Netherlands)

    Doze, P; Elsinga, PH; de Vries, EFJ; Van Waarde, A; Vaalburg, W

    S-1'[F-18]-Fluorocarazolol (FCAR) is a fluorinated analog of the nonmutagenic beta-blocker carazolol (CAR). Tn former studies FCAR proved to be suitable for quantification of beta-adrenoceptors in vivo with positron emission tomography (PET). We report here that FCAR displays no acute toxicity in

  13. Positron computed tomography studies: potential use in neuro-psychiatric disorders

    International Nuclear Information System (INIS)

    Yamasaki, T.; Tateno, Y.; Shishido, F.

    1982-01-01

    Since November 1979 positron computed tomography (PCT) have been performed to study subjects in a variety of states and varied disorders, using 13 NH 3 , 11 CO and 18 F-2-fluorodeoxyglucose ( 18 FDG) at the National Institute of Radiological Sciences, Japan. In neuro-psychiatric studies, normal volunteers and patients including schizophrenia, affective disorders, Alzheimer's disease, Huntigton's chorea were studied. Tomographic images were analyzed by visual observation and activity counting in regions selected. In degenerative disorder group, 18 FDG revealed decreased accumulation in target areas, whereas in functional psychosis group both in medicating patients and in non-medicated patients, positron images were basically similar to normal controls. Especially in a patient with Huntington's chorea, 18 FDG accumulation in striatal region was markedly decreased without significant change in the same region on X-ray CT and 13 NH 3 PCT

  14. Positron emission tomography in oncology

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This report describes the current and potential uses of positron emission tomography in clinical medicine and research related to oncology. Assessment will be possible of metabolism and physiology of tumors and their effects on adjacent tissues. Specific probes are likely to be developed for target sites on tumors, including monoclonal antibodies and specific growth factors that recognize tumors. To date, most oncological applications of positron emission tomography tracers have been qualitative; in the future, quantitative metabolic measurements should aid in the evaluation of tumor biology and response to treatment

  15. Positron energy distributions from a hybrid positron source based on channeling radiation

    International Nuclear Information System (INIS)

    Azadegan, B.; Mahdipour, A.; Dabagov, S.B.; Wagner, W.

    2013-01-01

    A hybrid positron source which is based on the generation of channeling radiation by relativistic electrons channeled along different crystallographic planes and axes of a tungsten single crystal and subsequent conversion of radiation into e + e − -pairs in an amorphous tungsten target is described. The photon spectra of channeling radiation are calculated using the Doyle–Turner approximation for the continuum potentials and classical equations of motion for channeled particles to obtain their trajectories, velocities and accelerations. The spectral-angular distributions of channeling radiation are found applying classical electrodynamics. Finally, the conversion of radiation into e + e − -pairs and the energy distributions of positrons are simulated using the GEANT4 package

  16. The neuromechanism underlying verbal analogical reasoning of metaphorical relations: an event-related potentials study.

    Science.gov (United States)

    Zhao, Ming; Meng, Huishan; Xu, Zhiyuan; Du, Fenglei; Liu, Tao; Li, Yongxin; Chen, Feiyan

    2011-11-24

    Using event-related potentials (ERPs), this study investigated the neuromechanism underlying verbal analogical reasoning of two different metaphorical relations: attributive metaphor and relational metaphor. The analogical reasoning of attributive metaphor (AM-AR) involves a superficial similarity between analogues, while the analogical reasoning of relational metaphor (RM-AR) requires a structural similarity. Subjects were asked to judge whether one word pair was semantically analogous to another word pair. Results showed that the schema induction stage elicited a greater N400 component at the right anterior scalp for the AM-AR and RM-AR tasks, possibly attributable to semantic processing of metaphorical word pairs. The N400 was then followed by a widely distributed P300 and a late negative component (LNC1) at the left anterior scalp. The P300 was possibly related to the formation of a relational category, while the LNC1 was possibly related to the maintenance of a reasoning cue in working memory. The analogy mapping stage elicited broadly distributed N400 and LNC2, which might indicate the presence of semantic retrieval and analogical transfer. In the answer production stage, all conditions elicited the P2 component due to early stimulus encoding. The largest P2 amplitude was in the RM-AR task. The RM-AR elicited a larger LPC than did the AM-AR, even though the baseline correction was taken as a control for the differential P2 effect. The LPC effect might suggest that relational metaphors involved more integration processing than attributive metaphors. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. The generation and development of the moderators for slow positron beam

    International Nuclear Information System (INIS)

    Yu Weizhong; Yuan Jiaping

    2001-01-01

    The positron annihilation technique is a sensitive tool for studying microdefects and phase transitions in various materials. Usually the energy of positrons is on the order of MeV and the implantation depth about 100 microns, so the bulk average defect density can be studied. In a slow positron beam the positron energy is about keV and the implantation depth a few microns, so surface defects can be detected. Positron moderator is the key device for obtaining a slow positron beam. The authors review the history and development of the positron moderator, including four methods that convert fast positrons into slow mono-energetic positrons and five array types. The tungsten moderator is the most widely used one while the inert gas solid moderator is the most efficient. Field-enhanced moderators with their high efficiency have great potential but need to be developed. The vane arrangement is the most commonly found

  18. Application of positron emission tomography in the lung

    International Nuclear Information System (INIS)

    Valind, S.O.; Wollmer, P.E.; Rhodes, C.G.

    1985-01-01

    The early application of positron emission tomography in the lung was mainly concerned with the investigation of the regional volume of the vascular and extravascular compartments, using measurements of fractional blood volume and lung density. However, in addition to its passive role in the exchange of oxygen and carbon dioxide, the lung exerts a number of active, metabolic functions such as the inactivation of circulating vasoactive compounds and the synthesis and release of biologically active substances. Furthermore, many of the pulmonary disorders originate at a cellular or metabolic level, or have metabolic consequences. Many of the substrates of biochemical reactions and the biologically active compounds, or their analogs, can be labeled with positron-emitting radioisotopes without disturbing their biological or biochemical characteristics. In combination with the development of the appropriate physiological and biochemical models, the quantitative measurements possible with PET provide a unique opportunity of regionally studying the metabolic processes of the lung of man in vivo. Hence, a range of different expressions of metabolism and of lung function can be evaluated and their interdependence can be studied regionally

  19. Development of an Electron-Positron Source for Positron Annihilation Lifetime Spectroscopy

    Science.gov (United States)

    2009-12-19

    REPORT Development of an electron- positron source for positron annihilation lifetime spectroscopy : FINAL REPORT 14. ABSTRACT 16. SECURITY...to generate radiation, to accelerate particles, and to produce electrons and positrons from vacuum. From applications using existing high-repetition...theoretical directions. This report reviews work directed toward the application of positron generation from laser interaction with matter 1. REPORT DATE

  20. Relating derived relations as a model of analogical reasoning: reaction times and event-related potentials.

    Science.gov (United States)

    Barnes-Holmes, Dermot; Regan, Donal; Barnes-Holmes, Yvonne; Commins, Sean; Walsh, Derek; Stewart, Ian; Smeets, Paul M; Whelan, Robert; Dymond, Simon

    2005-11-01

    The current study aimed to test a Relational Frame Theory (RFT) model of analogical reasoning based on the relating of derived same and derived difference relations. Experiment 1 recorded reaction time measures of similar-similar (e.g., "apple is to orange as dog is to cat") versus different-different (e.g., "he is to his brother as chalk is to cheese") derived relational responding, in both speed-contingent and speed-noncontingent conditions. Experiment 2 examined the event-related potentials (ERPs) associated with these two response patterns. Both experiments showed similar-similar responding to be significantly faster than different-different responding. Experiment 2 revealed significant differences between the waveforms of the two response patterns in the left-hemispheric prefrontal regions; different-different waveforms were significantly more negative than similar-similar waveforms. The behavioral and neurophysiological data support the RFT prediction that, all things being equal, similar-similar responding is relationally "simpler" than, and functionally distinct from, different-different analogical responding. The ERP data were fully consistent with findings in the neurocognitive literature on analogy. These findings strengthen the validity of the RFT model of analogical reasoning and supplement the behavior-analytic approach to analogy based on the relating of derived relations.

  1. Two-site Hubbard molecule with a spinless electron-positron pair

    KAUST Repository

    Cossu, Fabrizio

    2012-12-19

    We determine the eigenvalues of the two-site Hubbard molecule with one electron and one positron to describe the characteristics of electron-positron interactions in solids. While the effect of hopping is, in general, opposite to the effect of on-site interaction, we find a complex scenario for the electron-positron pair with a non-vanishing potential drop. We give analytical solutions and discuss the combined effects of the model parameters.

  2. Two-site Hubbard molecule with a spinless electron-positron pair

    KAUST Repository

    Cossu, Fabrizio; Schuster, Cosima; Schwingenschlö gl, Udo

    2012-01-01

    We determine the eigenvalues of the two-site Hubbard molecule with one electron and one positron to describe the characteristics of electron-positron interactions in solids. While the effect of hopping is, in general, opposite to the effect of on-site interaction, we find a complex scenario for the electron-positron pair with a non-vanishing potential drop. We give analytical solutions and discuss the combined effects of the model parameters.

  3. Radiation damage analysis by positron annihilation spectroscopy

    International Nuclear Information System (INIS)

    Siegel, R.W.

    1982-01-01

    Positron annihilation spectroscopy (PAS) has in recent years become a valuable new tool for investigating defects in metals. The ability of the positron to localize in a trapped state at various defect sites, in which the positron annihilates with unique characteristics, has enabled the positron to be used as a localized probe of these defect sites. Several reviews of the application of PAS to the study of defects in metals have been published, as have more general treatises on the applications of positron annihilation to the study of solids. PAS has made, and has considerably greater potential for, a significant contribution to radiation damage analysis in two areas of importance: (1) the determination of atomic-defect properties, a knowledge of which is necessary for the modeling required to couple the results of model experiments using electron and ion irradiation with the expected irradiation conditions of reactor systems, and (2) the monitoring and characterization of irradiation-induced microstructure development. A unique aspect of PAS for radiation damage analysis is the defect specificity of the annihilation characteristics of a trapped positron. In addition to its value as an independent analytical tool, PAS can be a useful complement to more traditional techniques for defect studies

  4. Progress toward magnetic confinement of a positron-electron plasma: nearly 100% positron injection efficiency into a dipole trap

    Science.gov (United States)

    Stoneking, Matthew

    2017-10-01

    The hydrogen atom provides the simplest system and in some cases the most precise one for comparing theory and experiment in atomics physics. The field of plasma physics lacks an experimental counterpart, but there are efforts underway to produce a magnetically confined positron-electron plasma that promises to represent the simplest plasma system. The mass symmetry of positron-electron plasma makes it particularly tractable from a theoretical standpoint and many theory papers have been published predicting modified wave and stability properties in these systems. Our approach is to utilize techniques from the non-neutral plasma community to trap and accumulate electrons and positrons prior to mixing in a magnetic trap with good confinement properties. Ultimately we aim to use a levitated superconducting dipole configuration fueled by positrons from a reactor-based positron source and buffer-gas trap. To date we have conducted experiments to characterize and optimize the positron beam and test strategies for injecting positrons into the field of a supported permanent magnet by use of ExB drifts and tailored static and dynamic potentials applied to boundary electrodes and to the magnet itself. Nearly 100% injection efficiency has been achieved under certain conditions and some fraction of the injected positrons are confined for as long as 400 ms. These results are promising for the next step in the project which is to use an inductively energized high Tc superconducting coil to produce the dipole field, initially in a supported configuration, but ultimately levitated using feedback stabilization. Work performed with the support of the German Research Foundation (DFG), JSPS KAKENHI, NIFS Collaboration Research Program, and the UCSD Foundation.

  5. Multi-pair states in electron–positron pair creation

    Directory of Open Access Journals (Sweden)

    Anton Wöllert

    2016-09-01

    Full Text Available Ultra strong electromagnetic fields can lead to spontaneous creation of single or multiple electron–positron pairs. A quantum field theoretical treatment of the pair creation process combined with numerical methods provides a description of the fermionic quantum field state, from which all observables of the multiple electron–positron pairs can be inferred. This allows to study the complex multi-particle dynamics of electron–positron pair creation in-depth, including multi-pair statistics as well as momentum distributions and spin. To illustrate the potential benefit of this approach, it is applied to the intermediate regime of pair creation between nonperturbative Schwinger pair creation and perturbative multiphoton pair creation where the creation of multi-pair states becomes nonnegligible but cascades do not yet set in. Furthermore, it is demonstrated how spin and helicity of the created electrons and positrons are affected by the polarization of the counterpropagating laser fields, which induce the creation of electron–positron pairs.

  6. Multi-pair states in electron–positron pair creation

    Energy Technology Data Exchange (ETDEWEB)

    Wöllert, Anton, E-mail: woellert@mpi-hd.mpg.de; Bauke, Heiko, E-mail: heiko.bauke@mpi-hd.mpg.de; Keitel, Christoph H.

    2016-09-10

    Ultra strong electromagnetic fields can lead to spontaneous creation of single or multiple electron–positron pairs. A quantum field theoretical treatment of the pair creation process combined with numerical methods provides a description of the fermionic quantum field state, from which all observables of the multiple electron–positron pairs can be inferred. This allows to study the complex multi-particle dynamics of electron–positron pair creation in-depth, including multi-pair statistics as well as momentum distributions and spin. To illustrate the potential benefit of this approach, it is applied to the intermediate regime of pair creation between nonperturbative Schwinger pair creation and perturbative multiphoton pair creation where the creation of multi-pair states becomes nonnegligible but cascades do not yet set in. Furthermore, it is demonstrated how spin and helicity of the created electrons and positrons are affected by the polarization of the counterpropagating laser fields, which induce the creation of electron–positron pairs.

  7. Multi-pair states in electron–positron pair creation

    International Nuclear Information System (INIS)

    Wöllert, Anton; Bauke, Heiko; Keitel, Christoph H.

    2016-01-01

    Ultra strong electromagnetic fields can lead to spontaneous creation of single or multiple electron–positron pairs. A quantum field theoretical treatment of the pair creation process combined with numerical methods provides a description of the fermionic quantum field state, from which all observables of the multiple electron–positron pairs can be inferred. This allows to study the complex multi-particle dynamics of electron–positron pair creation in-depth, including multi-pair statistics as well as momentum distributions and spin. To illustrate the potential benefit of this approach, it is applied to the intermediate regime of pair creation between nonperturbative Schwinger pair creation and perturbative multiphoton pair creation where the creation of multi-pair states becomes nonnegligible but cascades do not yet set in. Furthermore, it is demonstrated how spin and helicity of the created electrons and positrons are affected by the polarization of the counterpropagating laser fields, which induce the creation of electron–positron pairs.

  8. Ultrashort megaelectronvolt positron beam generation based on laser-accelerated electrons

    Science.gov (United States)

    Xu, Tongjun; Shen, Baifei; Xu, Jiancai; Li, Shun; Yu, Yong; Li, Jinfeng; Lu, Xiaoming; Wang, Cheng; Wang, Xinliang; Liang, Xiaoyan; Leng, Yuxin; Li, Ruxin; Xu, Zhizhan

    2016-03-01

    Experimental generation of ultrashort MeV positron beams with high intensity and high density using a compact laser-driven setup is reported. A high-density gas jet is employed experimentally to generate MeV electrons with high charge; thus, a charge-neutralized MeV positron beam with high density is obtained during laser-accelerated electrons irradiating high-Z solid targets. It is a novel electron-positron source for the study of laboratory astrophysics. Meanwhile, the MeV positron beam is pulsed with an ultrashort duration of tens of femtoseconds and has a high peak intensity of 7.8 × 1021 s-1, thus allows specific studies of fast kinetics in millimeter-thick materials with a high time resolution and exhibits potential for applications in positron annihilation spectroscopy.

  9. Analog synthetic biology.

    Science.gov (United States)

    Sarpeshkar, R

    2014-03-28

    We analyse the pros and cons of analog versus digital computation in living cells. Our analysis is based on fundamental laws of noise in gene and protein expression, which set limits on the energy, time, space, molecular count and part-count resources needed to compute at a given level of precision. We conclude that analog computation is significantly more efficient in its use of resources than deterministic digital computation even at relatively high levels of precision in the cell. Based on this analysis, we conclude that synthetic biology must use analog, collective analog, probabilistic and hybrid analog-digital computational approaches; otherwise, even relatively simple synthetic computations in cells such as addition will exceed energy and molecular-count budgets. We present schematics for efficiently representing analog DNA-protein computation in cells. Analog electronic flow in subthreshold transistors and analog molecular flux in chemical reactions obey Boltzmann exponential laws of thermodynamics and are described by astoundingly similar logarithmic electrochemical potentials. Therefore, cytomorphic circuits can help to map circuit designs between electronic and biochemical domains. We review recent work that uses positive-feedback linearization circuits to architect wide-dynamic-range logarithmic analog computation in Escherichia coli using three transcription factors, nearly two orders of magnitude more efficient in parts than prior digital implementations.

  10. Glucagon-like peptide-1 analogs against antipsychotic-induced weight gain: potential physiological benefits

    Science.gov (United States)

    2012-01-01

    Background Antipsychotic-induced weight gain constitutes a major unresolved clinical problem which may ultimately be associated with reducing life expectancy by 25 years. Overweight is associated with brain deterioration, cognitive decline and poor quality of life, factors which are already compromised in normal weight patients with schizophrenia. Here we outline the current strategies against antipsychotic-induced weight gain, and we describe peripheral and cerebral effects of the gut hormone glucagon-like peptide-1 (GLP-1). Moreover, we account for similarities in brain changes between schizophrenia and overweight patients. Discussion Current interventions against antipsychotic-induced weight gain do not facilitate a substantial and lasting weight loss. GLP-1 analogs used in the treatment of type 2 diabetes are associated with significant and sustained weight loss in overweight patients. Potential effects of treating schizophrenia patients with antipsychotic-induced weight gain with GLP-1 analogs are discussed. Conclusions We propose that adjunctive treatment with GLP-1 analogs may constitute a new avenue to treat and prevent metabolic and cerebral deficiencies in schizophrenia patients with antipsychotic-induced weight gain. Clinical research to support this idea is highly warranted. PMID:22891821

  11. Glucagon-like peptide-1 analogs against antipsychotic-induced weight gain: potential physiological benefits

    Directory of Open Access Journals (Sweden)

    Ebdrup Bjørn H

    2012-08-01

    Full Text Available Abstract Background Antipsychotic-induced weight gain constitutes a major unresolved clinical problem which may ultimately be associated with reducing life expectancy by 25 years. Overweight is associated with brain deterioration, cognitive decline and poor quality of life, factors which are already compromised in normal weight patients with schizophrenia. Here we outline the current strategies against antipsychotic-induced weight gain, and we describe peripheral and cerebral effects of the gut hormone glucagon-like peptide-1 (GLP-1. Moreover, we account for similarities in brain changes between schizophrenia and overweight patients. Discussion Current interventions against antipsychotic-induced weight gain do not facilitate a substantial and lasting weight loss. GLP-1 analogs used in the treatment of type 2 diabetes are associated with significant and sustained weight loss in overweight patients. Potential effects of treating schizophrenia patients with antipsychotic-induced weight gain with GLP-1 analogs are discussed. Conclusions We propose that adjunctive treatment with GLP-1 analogs may constitute a new avenue to treat and prevent metabolic and cerebral deficiencies in schizophrenia patients with antipsychotic-induced weight gain. Clinical research to support this idea is highly warranted.

  12. Investigation of positron moderator materials for electron-linac-based slow positron beamlines

    International Nuclear Information System (INIS)

    Suzuki, Ryoichi; Ohdaira, Toshiyuki; Uedono, Akira

    1998-01-01

    Positron re-emission properties were studied on moderator materials in order to improve the positron moderation system of electron-linac-based intense slow positron beamlines. The re-emitted positron fraction was measured on tungsten, SiC, GaN, SrTiO 3 , and hydrogen-terminated Si with a variable-energy pulsed positron beam. The results suggested that tungsten is the best material for the primary moderator of the positron beamlines while epitaxially grown n-type 6H-SiC is the best material for the secondary moderator. Defect characterization by monoenergetic positron beams and surface characterization by Auger electron spectroscopy were carried out to clarify the mechanism of tungsten moderator degradation induced by high-energy electron irradiation. The characterization experiments revealed that the degradation is due to both radiation-induced vacancy clusters and surface carbon impurities. For the restoration of degraded tungsten moderators, oxygen treatment at ∼900degC is effective. Furthermore, it was found that oxygen at the tungsten surface inhibits positronium formation; as a result, it can increase the positron re-emission fraction. (author)

  13. The Upgrade of the Neutron Induced Positron Source NEPOMUC

    Science.gov (United States)

    Hugenschmidt, C.; Ceeh, H.; Gigl, T.; Lippert, F.; Piochacz, C.; Pikart, P.; Reiner, M.; Weber, J.; Zimnik, S.

    2013-06-01

    In summer 2012, the new NEutron induced POsitron Source MUniCh (NEPOMUC) was installed and put into operation at the research reactor FRM II. At NEPOMUC upgrade 80% 113Cd enriched Cd is used as neutron-gamma converter in order to ensure an operation time of 25 years. A structure of Pt foils inside the beam tube generates positrons by pair production. Moderated positrons leaving the Pt front foil are electrically extracted and magnetically guided to the outside of the reactor pool. The whole design, including Pt-foils, the electric lenses and the magnetic fields, has been improved in order to enhance both the intensity and the brightness of the positron beam. After adjusting the potentials and the magnetic guide and compensation fields an intensity of about 3·109 moderated positrons per second is expected. During the first start-up, the measured temperatures of about 90°C ensure a reliable operation of the positron source. Within this contribution the features and the status of NEPOMUC upgrade are elucidated. In addition, an overview of recent positron beam experiments and current developments at the spectrometers is given.

  14. Low-energy positron and electron diffraction and positron-stimulated secondary electron emission from Cu(100)

    International Nuclear Information System (INIS)

    Weiss, A.H.

    1983-01-01

    The results of two series of experiments are reported. In the first, an electrostatically guided beam of low-energy (40-400 eV) positrons, delta/sub p/ was used to study low-energy positron diffraction (LEPD) from a Cu(100) surface under ultrahigh-vacuum conditions. Low-energy electron diffraction (LEED) data were obtained from the same sample in the same apparatus. Comparison of LEPD and LEED intensity versus energy data with model calculations made using computer programs developed by C.B. Duke and collaborators indicated that: LEPD data is adequately modeled using potentials with no exchange-correlation term. The inelastic mean free path, lambda/sub ee/, is shorter for positrons than for electrons at low (< approx.80 eV). LEED is better than LEPD at making a determination of the first-layer spacing of Cu(100) for the particular data set reported. In the second set of experiments, the same apparatus and sample were used to compare positron- and electron-stimulated secondary-electron emission (PSSEE and ESSEE). The results were found to be consistent with existing models of secondary-electron production for metals. The energy distributions of secondary-electrons had broad low-energy (<10 eV) peaks for both positron and electron stimulation. But the PSEE distribution showed no elastic peak. Measurements of secondary-electron angular distributions, found to be cosine-like in both the PSSEE and ESSEE case, were used to obtain total secondary yield ratios, delta, at four beam energies ranging from 40-400 eV. The secondary yield ratio for primary positrons and the yield for primary electrons, delta/sub e/, were similar at these energies. For 400-eV primary particles the secondary yields were found to be delta/sub p/ = 0.94 +/- 0.12 and delta/sub e/ = 0.94 +/- 0./12, giving a ratio of unity for positron-stimulated secondary yield to electron-stimulated secondary yield

  15. Positron-atom collisions

    International Nuclear Information System (INIS)

    Drachman, R.J.

    1984-01-01

    The past decade has seen the field of positron-atom collisions mature into an important sub-field of atomic physics. Increasingly intense positron sources are leading towards a situation in which electron and positron collision experiments will be on almost an equal footing, challenging theory to analyze their similarities and differences. The author reviews the advances made in theory, including dispersion theory, resonances, and inelastic processes. A survey of experimental progress and a brief discussion of astrophysical positronics is also included. (Auth.)

  16. Positron emission computerized tomography: a potential tool for in vivo quantitation of the distribution of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Huebner, K.F.; King, P.; Gibbs, W.D.; Washburn, L.C.; Hayes, R.L.

    1981-01-01

    The principles and some of the difficulties in quantitative positron emission computerized tomography have been discussed. We have shown that randoms and scattered events are a major cause of noise and counting errors in positron emission computerized tomography. The noise has been identified as a convoluting process and a mathematical solution has been presented. Examples of phantom studies and in vivo measurements have demonstrated that the distribution of positron emitting radiopharmaceuticals can be quantitated with much improved accuracy using the deconvolution equation to remove undesired noise

  17. Electron and positron interaction with pyrimidine: A theoretical investigation

    Science.gov (United States)

    Sinha, Nidhi; Antony, Bobby

    2018-03-01

    Pyrimidine (C4H4N2) is considered as the building block of nucleobases, viz., cytosine, thymine and uracil. They provide a blueprint for probing the scattering of radiation by DNA and RNA bases. In this article, we report the elastic and total scattering cross-sections for electron and positron scattering from the pyrimidine molecule, employing a spherical complex optical potential (SCOP) formalism for an extensive energy range of 10 eV to 5 keV. In the case of positron scattering, the original SCOP formalism is modified to adequately solve the positron-target dynamics. Moreover, a reasonable agreement is observed between the present results and other available datasets, for both electron and positron scattering. The cross-sections for electron and positron impact scattering by pyrimidine are necessary input data for codes that seek to simulate radiation damage, and hence are useful to model biomolecular systems.

  18. Positrons and positronium

    International Nuclear Information System (INIS)

    Jean, Y.C.; Lambrecht, R.M.

    1988-01-01

    This bibliography includes articles, proceedings, abstracts, reports and patents published between 1930 and 1984 on the subject of positrons, positron annihilation and positronium. The subject covers experimental and theoretical results in the areas of physics and chemistry of low and intermediate energy (< 0.6 MeV) positrons and positronium. The topics of interest are: fundamental properties, interactions with matter, nuclear technology, the history and philosophy of antimatter, the theory of the universe, and the applications of positrons in the chemical, physical, and biomedical sciences

  19. The Effects of Surface Reconstruction and Electron-Positron Correlation on the Annihilation Characteristics of Positrons Trapped at Semiconductor Surfaces

    International Nuclear Information System (INIS)

    Fazleev, N. G.; Jung, E.; Weiss, A. H.

    2009-01-01

    Experimental positron annihilation induced Auger electron spectroscopy (PAES) data from Ge(100) and Ge(111) surfaces display several strong Auger peaks corresponding to M 4,5 N 1 N 2,3 , M 2,3 M 4,5 M 4,5 , M 2,3 M 4,5 V, and M 1 M 4,5 M 4,5 Auger transitions. The integrated peak intensities of Auger transitions have been used to obtain experimental annihilation probabilities for the Ge 3d and 3p core electrons. The experimental data were analyzed by performing theoretical studies of the effects of surface reconstructions and electron-positron correlations on image potential induced surface states and annihilation characteristics of positrons trapped at the reconstructed Ge(100) and Ge(111) surfaces. Calculations of positron surface states and annihilation characteristics have been performed for Ge(100) surface with (2x1), (2x2), and (4x2) reconstructions, and for Ge(111) surface with c(2x8) reconstruction. Estimates of the positron binding energy and annihilation characteristics reveal their sensitivity to the specific atomic structure of the topmost layers of the semiconductor and to the approximations used to describe electron-positron correlations. The results of these theoretical studies are compared with the ones obtained for the reconstructed Si(100)-(2x1) and Si(111)-(7x7) surfaces.

  20. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  1. Cardiac positron emission tomography

    International Nuclear Information System (INIS)

    Eftekhari, M.; Ejmalian, G.

    2003-01-01

    Positron emission tomography is an intrinsically tool that provide a unique and unparalleled approach for clinicians and researchers to interrogate the heart noninvasively. The ability to label substances of physiological interest with positron-emitting radioisotopes has permitted insight into normal blood flow and metabolism and the alterations that occur with disease states. Positron emission tomography of the heart has evolved as a unique, noninvasive approach for the assessment of myocardial perfusion, metabolism, and function. Because of the intrinsic quantitative nature of positron emission tomography measurements as well as the diverse compounds that can be labeled with positron- emitting radioisotopes, studies with positron emission tomography have provided rich insight into the physiology of the heart under diverse conditions

  2. Probing the CuO planes with positrons in high Tc cuprates: theoretical predictions

    International Nuclear Information System (INIS)

    Barbiellini, B.; Jarlborg, T.; Massidda, S.; Peter, M.

    1995-01-01

    Positron annihilation spectroscopy is a useful tool to investigate the Fermi surface in high T c superconductors. To study the physics of the copper-oxygen subsystem that forms the Cu-O layers, it is important to provide theoretical predictions, on materials where there is a large overlap between the positron and the interesting Cu-O planes. We have performed first-principle electronic structure calculations obtained using the linear muffin-tin orbital and the full-potential linearized augmented plane wave methods. The positron charge distributions and their sensitivity to different potentials are calculated. Secondly, we have computed the annihilation rates and the electron-positron momentum density in order to give predictions of the Fermi surface signals. (orig.)

  3. BEPC II positron source

    International Nuclear Information System (INIS)

    Pei Guoxi; Sun Yaolin; Liu Jintong; Chi Yunlong; Liu Yucheng; Liu Nianzong

    2006-01-01

    BEPC II-an upgrade project of the Beijing Electron Positron Collider (BEPC) is a factory type of e + e - collider. The fundamental requirements for its injector linac are the beam energy of 1.89 GeV for on-energy injection and a 40 mA positron beam current at the linac end with a low beam emittance of 1.6 μm and a low energy spread of ±0.5% so as to guarantee a higher injection rate (≥50 mA/min) to the storage ring. Since the positron flux is proportional to the primary electron beam power on the target, the authors will increase the electron gun current from 4A to 10A by using a new electron gun system and increase the primary electron energy from 120 MeV to 240 MeV. The positron source itself is an extremely important system for producing more positrons, including a positron converter target chamber, a 12kA flux modulator, the 7m focusing module with DC power supplies and the support. The new positron production linac from the electron gun to the positron source has been installed into the tunnel. In what follows, the authors will emphasize the positron source design, manufacture and tests. (authors)

  4. Positron annihilation studies on bulk metallic glass and high intensity positron beam developments

    International Nuclear Information System (INIS)

    Asoka-Kumar, P.; Stoeffl, W.

    2003-01-01

    Positron annihilation spectroscopy is an ideal probe to examine atomic scale open-volume regions in materials. Below, we summarize the recent results on studies of open-volume regions of a multicomponent Zr-Ti-Ni-Cu-Be bulk metallic glass. Our studies establish two types of open-volume regions, one group that is too shallow to trap positrons at room temperature and becomes effective only at low temperatures and the other group that localizes positrons at room temperature and is large enough to accommodate hydrogen. The second half of the paper will concentrate on the high intensity positron program at Lawrence Livermore National Laboratory. A new positron production target is under development and we are constructing two experimental end stations to accommodate a pulsed positron microprobe and an experiment on positron diffraction and holography. Important design considerations of these experiments will be described. (author)

  5. On the average luminosity of electron positron collider and positron-producing energy

    International Nuclear Information System (INIS)

    Xie Jialin

    1985-01-01

    In this paper, the average luminosity of linac injected electron positron collider is investigated from the positron-producing energy point of view. When the energy of the linac injector is fixed to be less than the operating energy of the storage ring, it has been found that there exists a positron-producing energy to give optimum average luminosity. Two cases have been studied, one for an ideal storage ring with no single-beam instability and the other for practical storage ring with fast head-tail instability. The result indicates that there is a positron-producing energy corresponding to the minimum injection time, but this does not correspond to the optimum average luminosity for the practical storage rings. For Beijing Electron Positron Collider (BEPC), the positron-producing energy corresponding to the optimum average luminosity is about one tenth of the total injector energy

  6. Numerical determination of elastic positron- and electron-atom scattering phaseshifts

    International Nuclear Information System (INIS)

    Page, B.A.P.

    1976-01-01

    Numerical investigations of both the positron- and electron-hydrogen systems in the elastic scattering energy region are presented. For the positron-hydrogen system, modifications of the Kohn variational method are used in which the quantities etasub(v) and etasub(Q) are related to the trial wavefunction PSIsub(t) through integral expressions using approximations to the target wavefunction psi. The quantities etasub(v) and etasub(Q) become the Kohn elastic phaseshifts when the exact target wavefunction is used. From the results obtained for the positron-hydrogen system it is conjectured that if the values of either etasub(v) or etasub(Q) display a local maximum when all the nonlinear parameters of PSIsub(t) are varied, then this local maximum value is a good approximation to the Kohn elastic phaseshifts that would be obtained by replacing the approximate psi with the exact psi in the particular PSIsub(t) used in the calculations. Application of this procedure to the positron-helium elastic scattering system is given using Hylleraas-type approximations to the helium ground-state wavefunction. Both the positron- and electron-hydrogen systems are analysed in the elastic scattering energy region using a modified optical potential method. The results suggest that the local maximum value of the modified optical potential phaseshift when all the nonlinear parameters of PSIsub(t) are varied, is reasonably close to the normal optical potential phaseshift obtained when the exact psi is used. (author)

  7. The neural basis of analogical reasoning: an event-related potential study.

    Science.gov (United States)

    Qiu, Jiang; Li, Hong; Chen, Antao; Zhang, Qinglin

    2008-10-01

    The spatiotemporal analysis of brain activation during the execution of easy analogy (EA) and difficult analogy (DA) tasks was investigated using high-density event-related brain potentials (ERPs). Results showed that reasoning tasks (schema induction) elicited a more negative ERP deflection (N500-1000) than did the baseline task (BS) between 500 and 1000 ms. Dipole source analysis of difference waves (EA-BS and DA-BS) indicated that the negative components were both localized near the left thalamus, possibly associated with the retrieval of alphabetical information. Furthermore, DA elicited a more positive ERP component (P600-1000) than did EA in the same time window. Two generators of P600-1000 were located in the medial prefrontal cortex (BA10) and the left frontal cortex (BA6) which was possibly involved in integrating information in schema abstraction. In the stage of analogy mapping, a greater negativity (N400-600) in the reasoning tasks as compared to BS was found over fronto-central scalp regions. A generator of this effect was located in the left fusiform gyrus and was possibly related to associative memory and activation of schema. Then, a greater negativity in the reasoning tasks, in comparison to BS task, developed between 900-1200 ms (LNC1) and 2000-2500 ms (LNC2). Dipole source analysis (EA-BS) localized the generator of LNC1 in the left prefrontal cortex (BA 10) which was possibly related to mapping the schema to the target problem, and the generator of LNC2 in the left prefrontal cortex (BA 9) which was possibly related to deciding whether a conclusion correctly follows from the schema.

  8. Positron emission tomography

    International Nuclear Information System (INIS)

    Paans, A.M.J.

    1981-01-01

    Positron emitting radiopharmaceuticals have special applications in in-vivo studies of biochemical processes. The combination of a cyclotron for the production of radionuclides and a positron emission tomograph for the registration of the distribution of radioactivity in the body enables the measurement of local radioactivity concentration in tissues, and opens up new possibilities in the diagnosis and examination of abnormalities in the metabolism. The principles and procedures of positron emission tomography are described and the necessary apparatus considered, with emphasis on the positron camera. The first clinical applications using 55 Co bloemycine for tumor detection are presented. (C.F.)

  9. Intense positron beams and possible experiments

    International Nuclear Information System (INIS)

    Lynn, K.G.; Frieze, W.E.

    1983-07-01

    In this paper, we survey some of the ideas that have been proposed regarding the production of intense beams of low energy positrons. Various facilities to produce beams of this type are already under design or construction and other methods beyond those in use have been previously discussed. Moreover, a variety of potential experiments utilizing intense positron beams have been suggested. It is to be hoped that this paper can serve as a useful summary of some of the current ideas, as well as a stimulation for new ideas to be forthcoming at the workshop. 31 references

  10. Radioiodinated carnitine and acylcarnitine analogs as potential myocardial imaging agents

    International Nuclear Information System (INIS)

    McConnell, D.S.

    1991-01-01

    R-carnitine is extremely important in mammalian energy metabolism. Gamma-butyrobetaine, the immediate biosynthetic precursor to R-carnitine, is synthesized in many organs. However, only liver can hydroxylate gamma-butyrobetaine to carnitine. Thus the transport of carnitine from its site of synthesis to the site of utilization is of utmost importance. Carnitine is found in highest concentration in cardiac and skeletal muscle, where it is required for the transport of fatty acids into the mitochondria. Before fatty acids are utilized as fuel for the myocyte by beta-oxidation, they are bound to carnitine as an acylcarnitine ester at the 3-hydroxyl, and transported across the micochondrial membranes. R,S-Carnitine has been shown to be taken up by myocytes. The author has begun a study on the use of carnitine derivatives as potential carriers for the site-specific delivery of radioiodine to bidning sites in the myocardium. Such agents labeled with a gamma-emitting nuclide such as iodine-123 would be useful for the noninvasive imaging of these tissues. The aim was to synthesize a variety of radiolabeled analogs of carnitine and acylcarnitine to address questions of transport, binding and availability for myocardial metabolism. These analogs consist of N-alkylated derivatives of carnitine, acylcarnitine esters as well as carnitine amides and ethers. One C-alkylated derivative showed interesting biodistribution, elevated myocardial uptake and competition with carnitine for binding in the myocardium

  11. Proposal for a slow positron facility at Jefferson National Laboratory

    Science.gov (United States)

    Mills, Allen P.

    2018-05-01

    One goal of the JPos-17 International Workshop on Physics with Positrons was to ascertain whether it would be a good idea to expand the mission of the Thomas Jefferson National Accelerator Facility (JLab) to include science with low energy (i.e. "slow") spin polarized positrons. It is probably true that experimentation with slow positrons would potentially have wide-ranging benefits comparable to those obtained with neutron and x-ray scattering, but it is certain that the full range of these benefits will never be fully available without an infrastructure comparable to that of existing neutron and x-ray facilities. The role for Jefferson Laboratory would therefore be to provide and maintain (1) a dedicated set of machines for making and manipulating high intensity, high brightness beams of polarized slow positrons; (2) a suite of unique and easily used instruments of wide utility that will make efficient use of the positrons; and (3) a group of on-site positron scientists to provide scientific leadership, instrument development, and user support. In this note some examples will be given of the science that might make a serious investment in a positron facility worthwhile. At the same time, the lessons learned from various proposed and successful positron facilities will be presented for consideration.

  12. New techniques of positron annihilation

    International Nuclear Information System (INIS)

    1983-02-01

    Studies on new techniques of positron annihilation and its application to various fields are presented. First, production of slow positron and its characteristic features are described. The slow positron can be obtained from radioisotopes by using a positron moderator, proton beam bombardment on a boron target, and pair production by using an electron linear accelerator. Bright enhancement of the slow positron beam is studied. Polarized positron beam can be used for the study of the momentum distribution of an electron in ferromagnetic substances. Production of polarized positrons and measurements of polarization are discussed. Various phases of interaction between slow positrons and atoms (or molecules) are described. A comparative study of electron scavenging effects on luminescence and on positronium formation in cyclohexane is presented. The positron annihilation phenomena are applicable for the surface study. The microscopic information on the surface of porous material may be obtained. The slow positrons are also useful for the surface study. Production and application of slow muon (positive and negative) are presented in this report. (Kato, T.)

  13. Solvated Positron Chemistry - Positron Reactions with Pseudo-Halide Ions in Water

    DEFF Research Database (Denmark)

    Mogensen, O. E.; Pedersen, Niels Jørgen; Andersen, Jan Rud

    1982-01-01

    The hydrated positron e+aq reactions with SCN−, OCN−, CN−, S2− were studied by means of the angular correlation technique. The positron forms bound states with SCN−, CN−, and S2− but not with OCN−. Apparently, the e+aq reaction with SH− results in a positron bound state with S2−. It was difficult...

  14. Studies of Positron Generation from Ultraintense Laser-Matter Interactions

    Science.gov (United States)

    Williams, Gerald Jackson

    Laser-produced pair jets possess unique characteristics that offer great potential for their use in laboratory-astrophysics experiments to study energetic phenomenon such as relativistic shock accelerations. High-flux, high-energy positron sources may also be used to study relativistic pair plasmas and useful as novel diagnostic tools for high energy density conditions. Copious amounts of positrons are produced with MeV energies from directly irradiating targets with ultraintense lasers where relativistic electrons, accelerated by the laser field, drive positron-electron pair production. Alternatively, laser wakefield accelerated electrons can produce pairs by the same mechanisms inside a secondary converter target. This dissertation describes a series of novel experiments that investigate the characteristics and scaling of pair production from ultraintense lasers, which are designed to establish a robust platform for laboratory-based relativistic pair plasmas. Results include a simple power-law scaling to estimate the effective positron yield for elemental targets for any Maxwellian electron source, typical of direct laser-target interactions. To facilitate these measurements, a solenoid electromagnetic coil was constructed to focus emitted particles, increasing the effective collection angle of the detector and enabling the investigation of pair production from thin targets and low-Z materials. Laser wakefield electron sources were also explored as a compact, high repetition rate platform for the production of high energy pairs with potential applications to the creation of charge-neutral relativistic pair plasmas. Plasma accelerators can produce low-divergence electron beams with energies approaching a GeV at Hz frequencies. It was found that, even for high-energy positrons, energy loss and scattering mechanisms in the target create a fundamental limit to the divergence and energy spectrum of the emitted positrons. The potential future application of laser

  15. Neuroleptic binding sites: specific labeling in mice with [18F]haloperidol, a potential tracer for positron emission tomography

    International Nuclear Information System (INIS)

    Zanzonico, P.B.; Bigler, R.E.; Schmall, B.

    1983-01-01

    Haloperidol labeled with fluorine- 18 (T 1/2 . 110 min, positron emission 97%), prepared yielding .04 Ci/millimole by the Balz-Schiemann reaction, was evaluated in a murine model as a potential radiotracer for noninvasive determination, by positron-emission tomography, of regional concentrations of brain dopamine receptors in patients. As the haloperidol dose in mice was increased from 0.01 to 1000 micrograms/kg, the relative concentration of [ 18 F]haloperidol (microCi per g specimen/microCi per g of body mass), at one hour after injection decreased from 30 to 1.0 in the striatum and from 8.0 to 1.0 in the cerebellum. The striatal radioactivity, plotted as relative concentration against log of dose, decreased sigmoidally, presumably reflecting competition between labeled and unlabeled haloperidol for a single class of accessible binding sites. Because the cerebellum is relatively deficient in dopamine receptors, the observed decrease in cerebellar radioactivity may reflect a saturable component of haloperidol transport into brain. The high brain concentrations and the unexpectedly high striatum-to-cerebellum concentration ratios (greater than 4 at haloperidol doses less than or equal to 1 microgram/kg) suggest that [ 18 F]haloperidol warrants further investigation as a potential radiotracer for dopamine receptors

  16. Positron-Induced Luminescence

    Science.gov (United States)

    Stenson, E. V.; Hergenhahn, U.; Stoneking, M. R.; Pedersen, T. Sunn

    2018-04-01

    We report on the observation that low-energy positrons incident on a phosphor screen produce significantly more luminescence than electrons do. For two different wide-band-gap semiconductor phosphors (ZnS:Ag and ZnO:Zn), we compare the luminescent response to a positron beam with the response to an electron beam. For both phosphors, the positron response is significantly brighter than the electron response, by a factor that depends strongly on incident energy (0-5 keV). Positrons with just a few tens of electron-volts of energy (for ZnS:Ag) or less (for ZnO:Zn) produce as much luminescence as is produced by electrons with several kilo-electron-volts. We attribute this effect to valence band holes and excited electrons produced by positron annihilation and subsequent Auger processes. These results demonstrate a valuable approach for addressing long-standing questions about luminescent materials.

  17. First image from a combined positron emission tomography and field-cycled MRI system.

    Science.gov (United States)

    Bindseil, Geron A; Gilbert, Kyle M; Scholl, Timothy J; Handler, William B; Chronik, Blaine A

    2011-07-01

    Combining positron emission tomography and MRI modalities typically requires using either conventional MRI with a MR-compatible positron emission tomography system or a modified MR system with conventional positron emission tomography. A feature of field-cycled MRI is that all magnetic fields can be turned off rapidly, enabling the use of conventional positron emission tomography detectors based on photomultiplier tubes. In this demonstration, two photomultiplier tube-based positron emission tomography detectors were integrated with a field-cycled MRI system (0.3 T/4 MHz) by placing them into a 9-cm axial gap. A positron emission tomography-MRI phantom consisting of a triangular arrangement of positron-emitting point sources embedded in an onion was imaged in a repeating interleaved sequence of ∼1 sec MRI then 1 sec positron emission tomography. The first multimodality images from the combined positron emission tomography and field-cycled MRI system show no additional artifacts due to interaction between the systems and demonstrate the potential of this approach to combining positron emission tomography and MRI. Copyright © 2010 Wiley-Liss, Inc.

  18. Positron Factory project

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Sohei; Sunaga, Hiromi; Kaneko, Hirohisa; Kawasuso, Atsuo; Masuno, Shin-ichi; Takizawa, Haruki; Yotsumoto, Keiichi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    We have started drafting a construction program for the Positron Factory, in which linac-based intense monoenergetic positron beams are planned to be applied for materials science, biotechnology and basic physics and chemistry. A technical survey study confirmed the feasibility of manufacturing a dedicated electron linac of 100 kW class with a beam energy of 100 MeV, which will produce a world-highest monoenergetic positron beam of more than 10{sup 10}/sec in intensity. A self-driven rotating converter (electrons to positrons and photons) suitable for the high power electron beam was devised and successfully tested. The practicability of simultaneous extraction of multi-channel monoenergetic positron beams with multiple moderator assemblies, which had been originated on the basis of a Monte Carlo simulation, was demonstrated by an experiment using an electron linac. An efficient moderator structure, which is composed of honeycomb-like assembled moderator foils and reflectors, is also proposed. (author)

  19. Development of a Slow Positron Facility at Hebrew University of Jerusalem

    Science.gov (United States)

    Kelleher, Aidan

    2013-03-01

    Positron annihilation spectroscopy provides both depth of penetration to study bulk defects in materials as well as nano-scale resolution. This measurement range is achieved by slowing positrons from a radioactive source, typically 22Na, by sending them through a moderator, typically W or solid Ne. The nearly thermal positrons are then accelerated to the desired energy by means of an electrostatic potential. The SPOT project at The Hebrew University of Jerusalem proposes to increase the luminosity of the beam by applying the best practices currently in us, as well as using a short-lived source of positrons, 18F. Simulations based on our current designs indicate this project will be able to deliver positrons in the energy range of 50-50000eV with an energy resolution of 1eV is possible. We will present the unique technical challenges of using this source of positrons, how we plan to overcome them, the results of simulations, and facility construction progress.

  20. KEK-IMSS Slow Positron Facility

    Energy Technology Data Exchange (ETDEWEB)

    Hyodo, T; Wada, K; Yagishita, A; Kosuge, T; Saito, Y; Kurihara, T; Kikuchi, T; Shirakawa, A; Sanami, T; Ikeda, M; Ohsawa, S; Kakihara, K; Shidara, T, E-mail: toshio.hyodo@kek.jp [High Energy Accelerator Research Organization (KEK) 1-1 Oho, Tsukuba, Ibaraki, 305-0801 (Japan)

    2011-12-01

    The Slow Positron Facility at the Institute of Material Structure Science (IMSS) of High Energy Accelerator Research Organization (KEK) is a user dedicated facility with an energy tunable (0.1 - 35 keV) slow positron beam produced by a dedicated 55MeV linac. The present beam line branches have been used for the positronium time-of-flight (Ps-TOF) measurements, the transmission positron microscope (TPM) and the photo-detachment of Ps negative ions (Ps{sup -}). During the year 2010, a reflection high-energy positron diffraction (RHEPD) measurement station is going to be installed. The slow positron generator (converter/ moderator) system will be modified to get a higher slow positron intensity, and a new user-friendly beam line power-supply control and vacuum monitoring system is being developed. Another plan for this year is the transfer of a {sup 22}Na-based slow positron beam from RIKEN. This machine will be used for the continuous slow positron beam applications and for the orientation training of those who are interested in beginning researches with a slow positron beam.

  1. Positron deposition in plasmas by positronium beam ionization and transport of positrons in tokamak plasmas

    International Nuclear Information System (INIS)

    Murphy, T.J.

    1986-11-01

    In a recently proposed positron transport experiment, positrons would be deposited in a fusion plasma by forming a positronium (Ps) beam and passing it through the plasma. Positrons would be deposited as the beam is ionized by plasma ions and electrons. Radial transport of the positrons to the limiter could then be measured by detecting the gamma radiation produced by annihilation of positrons with electrons in the limiter. This would allow measurements of the transport of electron-mass particles and might shed some light on the mechanisms of electron transport in fusion plasmas. In this paper, the deposition and transport of positrons in a tokamak are simulated and the annihilation signal determined for several transport models. Calculations of the expected signals are necessary for the optimal design of a positron transport experiment. There are several mechanisms for the loss of positrons besides transport to the limiter. Annihilation with plasma electrons and reformation of positronium in positron-hydrogen collisions are two such processes. These processes can alter the signal and place restrictions ons on the plasma conditions in which positron transport experiments can be effectively performed

  2. A feature point identification method for positron emission particle tracking with multiple tracers

    Energy Technology Data Exchange (ETDEWEB)

    Wiggins, Cody, E-mail: cwiggin2@vols.utk.edu [University of Tennessee-Knoxville, Department of Physics and Astronomy, 1408 Circle Drive, Knoxville, TN 37996 (United States); Santos, Roque [University of Tennessee-Knoxville, Department of Nuclear Engineering (United States); Escuela Politécnica Nacional, Departamento de Ciencias Nucleares (Ecuador); Ruggles, Arthur [University of Tennessee-Knoxville, Department of Nuclear Engineering (United States)

    2017-01-21

    A novel detection algorithm for Positron Emission Particle Tracking (PEPT) with multiple tracers based on optical feature point identification (FPI) methods is presented. This new method, the FPI method, is compared to a previous multiple PEPT method via analyses of experimental and simulated data. The FPI method outperforms the older method in cases of large particle numbers and fine time resolution. Simulated data show the FPI method to be capable of identifying 100 particles at 0.5 mm average spatial error. Detection error is seen to vary with the inverse square root of the number of lines of response (LORs) used for detection and increases as particle separation decreases. - Highlights: • A new approach to positron emission particle tracking is presented. • Using optical feature point identification analogs, multiple particle tracking is achieved. • Method is compared to previous multiple particle method. • Accuracy and applicability of method is explored.

  3. Positron annihilation lifetime study of oxide dispersion strengthened steels

    International Nuclear Information System (INIS)

    Krsjak, V.; Szaraz, Z.; Hähner, P.

    2012-01-01

    A comparative positron annihilation lifetime study has been performed on various commercial ferritic and ferritic/martensitic oxide dispersion strengthened (ODS) steels. Both as-extruded and recrystallized materials were investigated. In the materials with recrystallized coarse-grained microstructures, only the positron trapping at small vacancy clusters and yttria nanofeatures was observed. Materials which had not undergone recrystallization treatment clearly showed additional positron trapping which is associated with dislocations. Dislocation densities were calculated from a two-component decomposition of the positron lifetime spectra by assuming the first component to be a superposition of the bulk controlled annihilation rate and the dislocation controlled trapping rate. The second component (which translates into lifetimes of 240–260 ps) was found to be well separated in all those ODS materials. This paper presents the potentialities and limitations of the positron annihilation lifetime spectroscopy, and discusses the results of the experimental determination of the defect concentrations and sensitivity of this technique to the material degradation due to thermally induced precipitation of chromium-rich α′ phases.

  4. Molecular model for annihilation rates in positron complexes

    Energy Technology Data Exchange (ETDEWEB)

    Assafrao, Denise [Laboratorio de Atomos e Moleculas Especiais, Departamento de Fisica, ICEx, Universidade Federal de Minas Gerais, P.O. Box 702, 30123-970 Belo Horizonte, MG (Brazil); Department of Applied Mathematics and Theoretical Physics, Queen' s University of Belfast, Belfast BT7 1NN, Northern Ireland (United Kingdom); Walters, H.R. James [Department of Applied Mathematics and Theoretical Physics, Queen' s University of Belfast, Belfast BT7 1NN, Northern Ireland (United Kingdom); Mohallem, Jose R. [Laboratorio de Atomos e Moleculas Especiais, Departamento de Fisica, ICEx, Universidade Federal de Minas Gerais, P.O. Box 702, 30123-970 Belo Horizonte, MG (Brazil); Department of Applied Mathematics and Theoretical Physics, Queen' s University of Belfast, Belfast BT7 1NN, Northern Ireland (United Kingdom)], E-mail: rachid@fisica.ufmg.br

    2008-02-15

    The molecular approach for positron interaction with atoms is developed further. Potential energy curves for positron motion are obtained. Two procedures accounting for the nonadiabatic effective positron mass are introduced for calculating annihilation rate constants. The first one takes the bound-state energy eigenvalue as an input parameter. The second is a self-contained and self-consistent procedure. The methods are tested with quite different states of the small complexes HPs, e{sup +}He (electronic triplet) and e{sup +}Be (electronic singlet and triplet). For states yielding the positronium cluster, the annihilation rates are quite stable, irrespective of the accuracy in binding energies. For the e{sup +}Be states, annihilation rates are larger and more consistent with qualitative predictions than previously reported ones.

  5. Molecular model for annihilation rates in positron complexes

    International Nuclear Information System (INIS)

    Assafrao, Denise; Walters, H.R. James; Mohallem, Jose R.

    2008-01-01

    The molecular approach for positron interaction with atoms is developed further. Potential energy curves for positron motion are obtained. Two procedures accounting for the nonadiabatic effective positron mass are introduced for calculating annihilation rate constants. The first one takes the bound-state energy eigenvalue as an input parameter. The second is a self-contained and self-consistent procedure. The methods are tested with quite different states of the small complexes HPs, e + He (electronic triplet) and e + Be (electronic singlet and triplet). For states yielding the positronium cluster, the annihilation rates are quite stable, irrespective of the accuracy in binding energies. For the e + Be states, annihilation rates are larger and more consistent with qualitative predictions than previously reported ones

  6. Positron emission tomographic imaging of tumors using monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Zalutsky, M.R.

    1992-08-01

    This research project is developing methods for utilizing positron emission tomography (PET) to increase the clinical potential of radiolabeled monoclonal antibodies (MAbs). This report describes the development of methods for labeling MAbs and their fragments with positron-emitting halogen nuclides, fluorine-18 and iodine-124. These nulides were selected because of the widespread availability of F-18 and because of our extensive experience in the development of new protein radiohalogenation methods.

  7. CO ionization and fragmentation by low-energy positrons.

    Science.gov (United States)

    Schrader, D. M.; Moxom, J.

    2000-06-01

    Using the positron beam associated with the electron LINAC ORELA at Oak Ridge National Laboratory, ion yields from carbon monoxide colliding with positrons of low energy are observed as functions of positron beam energy from threshold to 100 eV. Observed appearence potentials are compared with those for electron bombardment, and are interpreted with the aid of potential energy curves for CO, CO^+, and CO^2+. The latter are calculated in the present work at the FORS/MCSCF level using the code GAMESS.^(a) Present results are compared with those of Bluhme, et al.^(b) Progress on our work with the targets N2 and O2 will be discussed and with present results for CO. It is significant that CO and N2 are very similar, but that CO gives a richer mass spectrum because the atomic cations are experimentally distinguishable from the molecular dication. ^(a) M. W. Schmidt, et al., J. Comput. Chem. 14, 1347 (1993). ^(b) H. Bluhme, et al., J. Phys. B 32, 5825 (1999).

  8. A transmission positron microscope and a scanning positron microscope being built at KEK, Japan

    International Nuclear Information System (INIS)

    Doyama, M.; Inoue, M.; Kogure, Y.; Kurihara, T.; Yagishita, A.; Shidara, T.; Nakahara, K.; Hayashi, Y.; Yoshiie, T.

    2001-01-01

    This paper reports the plans of positron microscopes being built at KEK (High Energy Accelerator Research Organization), Tsukuba, Japan improving used electron microscopes. The kinetic energies of positron produced by accelerators or by nuclear decays have not a unique value but show a spread over in a wide range. Positron beam will be guided near electron microscopes, a transmission electron microscope (JEM100S) and a scanning electron microscope (JSM25S). Positrons are slowed down by a tungsten foil, accelerated and focused on a nickel sheet. The monochromatic focused beam will be injected into an electron microscope. The focusing of positrons and electrons is achieved by magnetic system of the electron microscopes. Imaging plates are used to record positron images for the transmission electron microscope. (orig.)

  9. Positron annihilation induced Auger electron spectroscopic studies of oxide surfaces

    Science.gov (United States)

    Nadesalingam, Manori

    2005-03-01

    Defects on oxide surfaces are well known to play a key role in catalysis. TiO2, MgO, SiO2 surfaces were investigated using Time-Of-Flight Positron induced Auger Electron Spectroscopy (TOF-PAES). Previous work in bulk materials has demonstrated that positrons are particularly sensitive to charged defects. In PAES energetic electron emission results from Auger transitions initiated by annihilation of core electrons with positrons trapped in an image-potential well at the surface. Annealed samples in O2 environment show a strong Auger peak of Oxygen. The implication of these results will be discussed

  10. Potential energy curves for the interaction of a low-energy positron with matter: The case He+e{sup +}

    Energy Technology Data Exchange (ETDEWEB)

    Mohallem, Jose R. [Laboratorio de Atomos e Moleculas Especiais, Departamento de Fisica, ICEx, Universidade Federal de Minas Gerais, P.O. Box 702, 30123-970 Belo Horizonte, MG (Brazil)]. E-mail: rachid@fisica.ufmg.br; Rolim, Flavia [Departamento de Quimica, Universidade de Coimbra, FCT, 3004-535 Coimbra (Portugal)

    2007-02-15

    In this introductory exploration of the title theme, we treat a positron as a light nucleus and work within the quasi-molecule approximation to obtain, for the first time, adiabatic potential energy curves for its scattering by the He atom. We then show that different elastic and inelastic processes that contribute to the total scattering cross section can be rationalized in molecular terms as dissociation and non-adiabatic couplings. Particularly, some new insights on positronium yielding are presented.

  11. Theory, development, and applications of the scanning positron microbeam and positron reemission microscope

    International Nuclear Information System (INIS)

    Brandes, G.R.

    1990-01-01

    The theory, design, development, and applications of two new imaging instruments, the scanning positron microbeam (SPM) and positron reemission microscope (PRM), are discussed. The SPM consists of a sectored lens which focuses and rasters the positrons from the beam across the sample. The results of rastering the 10μm x 50μm beam across a test grid demonstrate the SPM's ability to scan a 500μm diameter region and to resolve features with ∼ 5μm resolution. The SPM was used to examine the location of defects in a Si-on-SiO 2 sample. Possible applications to three dimensional defect spectroscopy and the observation of small samples are considered. In the PRM, the positrons from the brightness-enhanced beam are focused at 5keV to an 8/Am diameter spot (FWHM) onto a thin metal single crystal. An image of the opposing side of the film is formed by accelerating and focusing the reemitted thermalized positrons with a cathode lens objective and a projector lens. The final image (real) is a record of the thermal positron emission intensity versus position. Images of surface and subsurface defect structures, taken at magnifications up to 4400x and with a resolution up to 80nm, are presented and discussed. The ultimate resolution capabilities and possible applications of the PRM are examined. The implantation and diffusion process of positrons was studied with the PRM by examining the positron emission profile of 3-9keV positrons implanted into a 2200 angstrom thick Ni single crystal

  12. Positron studies in catalysis research

    International Nuclear Information System (INIS)

    1994-01-01

    During the past eight months, the authors have made progress in several areas relevant to the eventual use of positron techniques in catalysis research. They have come closer to the completion of their positron microscope, and at the same time have performed several studies in their non-microscopic positron spectrometer which should ultimately be applicable to catalysis. The current status of the efforts in each of these areas is summarized in the following sections: Construction of the positron microscope (optical element construction, data collection software, and electronic sub-assemblies); Doppler broadening spectroscopy of metal silicide; Positron lifetime spectroscopy of glassy polymers; and Positron lifetime measurements of pore-sizes in zeolites

  13. 22 Na positron source for annihilation positron spectroscopy

    International Nuclear Information System (INIS)

    Cimpeanu, Catalina; Craciun, L.; Dragulescu, E.; Dudu, D.; Racolta, P. M.; Voiculescu, Dana; Miron, N.

    2003-01-01

    To extend the nuclear physics applications and to perform the study of vacancy - type defects in metals, semiconductors, polymers etc., we decided to promote positron annihilation techniques. In order to achieve this goal we started a project of dedicated positron sources produced at the IFIN-HH U-120 Cyclotron. We have used the nuclear reaction: 24 Mg(d,α) 22 Na with deuterons of 13 MeV energy. The paper presents the main characteristics of this procedure, as follows: general conditions asked for 22 NaCl sources, reactive chamber and characteristics of Mg target, parameters for the irradiation, radiochemical procedures for separating Na from Mg after the irradiation and geometrical or mechanical requirements for dedicated NaCl source for positron annihilation spectrometry. In the e + lifetime measurements, the e + end - start signals may be obtained from prompt γ -quanta emitted from the NaCl source (1. 275 MeV photons). The 22 NaCl stock solution obtained by radiochemical separation will be kept in quartz sealed ampoules in dry places and will be dropped between the study materials before the use in positron spectrometry. (authors)

  14. Slow positron applications at slow positron facility of institute of materials structure science, KEK

    Science.gov (United States)

    Hyodo, Toshio; Mochizuki, Izumi; Wada, Ken; Toge, Nobukazu; Shidara, Tetsuo

    2018-05-01

    Slow Positron Facility at High Energy Accelerator Research Organization (KEK) is a user dedicated facility with an energy-tunable (0.1 - 35 keV) slow positron beam created by a dedicated ˜ 50 MeV linac. It operates in a short pulse (width 1-12 ns, variable, 5×106 e+/s) and a long pulse (width 1.2 µs, 5×107 e+/s) modes of 50 Hz. High energy positrons from pair creation are moderated by reemission after thermalization in W foils. The reemitted positrons are then electrostatically accelerated to a desired energy up to 35 keV and magnetically transported. A pulse-stretching section (pulse stretcher) is installed in the middle of the beamline. It stretches the slow positron pulse for the experiments where too many positrons annihilating in the sample at the same time has to be avoided. Four experiment stations for TRHEPD (total-reflection high-energy positron diffraction), LEPD (low-energy positron diffraction), Ps- (positronium negative ion), and Ps-TOF (positronium time-of-flight) experiments are connected to the beamline branches, SPF-A3, SPF-A4, SPF-B1 and SPF-B2, respectively. Recent results of these stations are briefly described.

  15. Positron effective mass in silicon

    International Nuclear Information System (INIS)

    Panda, B.K.; Shan, Y.Y.; Fung, S.; Beling, C.D.

    1995-01-01

    The positron effective mass in Si is obtained from the first-principles calculations along various crystallographic directions. The effect of electron-positron correlation on the band mass is examined in this work. A positron pseudopotential scheme is worked out to calculate the isotropic band mass without explicitly solving the band energy. The effective mass 1.46m obtained as a sum of band mass and the positron-plasmon interaction compares very well with 1.5m obtained from the positron mobility data

  16. Positron emission tomography

    International Nuclear Information System (INIS)

    Iio, Masahiro

    1982-01-01

    Utilization of positron emission tomography was reviewed in relation to construction and planned construction of small-size medical cyclotrons, planned construction of positron cameras and utilization of short-lived radionuclides. (Chiba, N.)

  17. Analysis of sub-nano spaces by positron annihilation spectroscopy

    International Nuclear Information System (INIS)

    Jean, Y.C.; Liu, J.; Huang, C.M.; Dai, G.H.; Yuan, J.P.

    1994-01-01

    Positron annihilation spectroscopy (PAS) has been realized to be a novel and potentially powerful tool to evolve the open spaces in the range 1-20 angstrom in molecular systems. Due to the repulsive force between the positron (the anti-particle of the electron) and the cores, annihilation signals are solely contributed from the open spaces, such as vacancies, holes, and voids in the molecular subtracts under study. By further developing two PAS techniques, positron lifetime (PAL), and angular correlation (ACAR), the authors are able to obtain useful and important information of: hole sizes, distributions, hole fractions, and anisotropic structures at sub-nano scales. Applications of PAS to chemical analysis, surface chemistry of inner pores, and polymer sciences are discussed

  18. Generation of a high-brightness pulsed positron beam for the Munich scanning positron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Piochacz, Christian

    2009-11-20

    Within the present work the prerequisites for the operation of the Munich scanning positron microscope (SPM) at the high intense neutron induced positron source Munich (NEPOMUC) were established. This was accomplished in two steps: Firstly, a re-moderation device was installed at the positron beam facility NEPOMUC, which enhances the brightness of the positron beam for all connected experiments. The second step was the design, set up and initial operation of the SPM interface for the high efficient conversion of the continuous beam into a bunched beam. The in-pile positron source NEPOMUC creates a positron beam with a diameter of typically 7 mm, a kinetic energy of 1 keV and an energy spread of 50 eV. The NEPOMUC re-moderator generates from this beam a low energy positron beam (20 - 200 eV) with a diameter of less than 2 mm and an energy spread well below 2.5 eV. This was achieved with an excellent total efficiency of 6.55{+-}0.25 %. The re-moderator was not only the rst step to implement the SPM at NEPOMUc, it enables also the operation of the pulsed low energy positron beam system (PLEPS). Within the present work, at this spectrometer rst positron lifetime measurements were performed, which revealed the defect types of an ion irradiated uranium molybdenum alloy. Moreover, the instruments which were already connected to the positron beam facility bene ts considerably of the high brightness enhancement. In the new SPM interface an additional re-moderation stage enhances the brightness of the beam even more and will enable positron lifetime measurements at the SPM with a lateral resolution below 1 {mu}m. The efficiency of the re-moderation process in this second stage was 24.5{+-}4.5 %. In order to convert high efficiently the continuous positron beam into a pulsed beam with a repetition rate of 50 MHz and a pulse duration of less than 50 ps, a sub-harmonic pre-bucher was combined with two sine wave bunchers. Furthermore, the additional re-moderation stage of the

  19. Generation of a high-brightness pulsed positron beam for the Munich scanning positron microscope

    International Nuclear Information System (INIS)

    Piochacz, Christian

    2009-01-01

    Within the present work the prerequisites for the operation of the Munich scanning positron microscope (SPM) at the high intense neutron induced positron source Munich (NEPOMUC) were established. This was accomplished in two steps: Firstly, a re-moderation device was installed at the positron beam facility NEPOMUC, which enhances the brightness of the positron beam for all connected experiments. The second step was the design, set up and initial operation of the SPM interface for the high efficient conversion of the continuous beam into a bunched beam. The in-pile positron source NEPOMUC creates a positron beam with a diameter of typically 7 mm, a kinetic energy of 1 keV and an energy spread of 50 eV. The NEPOMUC re-moderator generates from this beam a low energy positron beam (20 - 200 eV) with a diameter of less than 2 mm and an energy spread well below 2.5 eV. This was achieved with an excellent total efficiency of 6.55±0.25 %. The re-moderator was not only the rst step to implement the SPM at NEPOMUc, it enables also the operation of the pulsed low energy positron beam system (PLEPS). Within the present work, at this spectrometer rst positron lifetime measurements were performed, which revealed the defect types of an ion irradiated uranium molybdenum alloy. Moreover, the instruments which were already connected to the positron beam facility bene ts considerably of the high brightness enhancement. In the new SPM interface an additional re-moderation stage enhances the brightness of the beam even more and will enable positron lifetime measurements at the SPM with a lateral resolution below 1 μm. The efficiency of the re-moderation process in this second stage was 24.5±4.5 %. In order to convert high efficiently the continuous positron beam into a pulsed beam with a repetition rate of 50 MHz and a pulse duration of less than 50 ps, a sub-harmonic pre-bucher was combined with two sine wave bunchers. Furthermore, the additional re-moderation stage of the SPM

  20. Positrons as imaging agents and probes in nanotechnology

    International Nuclear Information System (INIS)

    Smith, Suzanne V

    2009-01-01

    Positron emission tomography (PET) tracks a positron emitting radiopharmaceutical injected into the body and generates a 3-dimensional image of its location. Introduced in the early 70s, it has now developed into a powerful medical diagnostic tool for routine clinical use as well as in drug development. Unrivalled as a highly sensitive, specific and non-invasive imaging tool, PET unfortunately lacks the resolution of Computer Tomography (CT) and Magnetic Resonance Imaging (MRI). As the resolution of PET depends significantly on the energy of the positron incorporated in the radiopharmaceutical and its interaction with its surrounding tissue, there is growing interest in expanding our understanding of how positrons interact at the atomic and molecular level. A better understanding of these interactions will contribute to improving the resolution of PET and assist in the design of better imaging agents. Positrons are also used in Positron Annihilation Lifetime Spectroscopy (PALS) to determine electron density and or presence and incidence of micro- and mesopores (0.1 to 10 nm) in materials. The control of porosity in engineered materials is crucial for applications such as controlled release or air and water resistant films. Equally important to the design of nano and microtechnologies, is our understanding of the microenvironments within these pores and on surfaces. Hence as radiopharmaceuticals are designed to track disease, nuclear probes (radioactive molecules) are synthesized to investigate the chemical properties within these pores. This article will give a brief overview of the present role of positrons in imaging as well as explore its potential to contribute in the engineering of new materials to the marketplace.

  1. Positron sources for electron-positron colliders application to the ILC and CLIC

    CERN Multimedia

    CERN. Geneva

    2008-01-01

    The increased demanding qualities for positron sources dedicated to e+e- colliders pushed on investigations oriented on new kinds of e+ sources. The different kinds of positron sources polarized and no polarized are considered. Their main features (intensity, emittance) are described and analysed. Comparison between the different sources is worked out. The characteristics of the positron beam available in the collision point are greatly depending on the capture device and on the positron accelerator. Different kinds of capture systems are considered and their qualities, compared. Intense positron sources which are necessary for the colliders require intense incident beams (electrons or photons). The large number of pairs created in the targets leads to important energy deposition and so, thermal heating, which associated to temperature gradients provoke mechanical stresses often destructive. Moreover, the important Coulomb collisions, can affect the atomic structure in crystal targets and the radiation resist...

  2. A coupled channel study on a binding mechanism of positronic alkali atoms

    International Nuclear Information System (INIS)

    Kubota, Yoshihiro; Kino, Yasushi

    2008-01-01

    In order to investigate the binding mechanism of weakly bound states of positronic alkali atoms, we calculate the energies and wavefunctions using the Gaussian expansion method (GEM) where a positronium (Ps)-alkali ion channel and a positron-alkali atom channel are explicitly introduced. The energies of the bound states are updated using a model potential that reproduces well the observed energy levels of alkali atoms. The binding mechanism of the positronic alkali atom is analyzed by the wavefunctions obtained. The structure of the positronic alkali atom has been regarded as a Ps cluster orbiting the alkali ion, which is described by the Ps-alkali ion channel. We point out that the fraction having the positron-alkali atom configuration is small but plays an indispensable role for the weakly bound system

  3. Investigation on the porosity of zeolite NU-88 by means of positron annihilation lifetime spectroscopy

    International Nuclear Information System (INIS)

    Consolati, G.; Mariani, M.; Millini, R.; Quasso, F.

    2009-01-01

    Seven well characterized zeolites were investigated by positron annihilation lifetime spectroscopy. The lifetime spectra were analysed in four discrete components. The third one was associated with ortho-positronium annihilation in the channels, framed in terms of infinite cylinders. Differences between the radii determined from the positron annihilation technique and X-ray diffraction data were found and explained in terms of the physical structure of the channel. An analogous study on a high-silica NU-88 zeolite gave a value of 0.33 nm for the corresponding radius, in agreement with Ar and N 2 adsorption data as well as with the catalytic behaviour of this zeolite in several acid catalyzed reactions. The longest lifetime component in NU-88 reveals the existence of mesopores, with average radius of about 1.8 nm, which could explain the importance of hydrogen transfer reactions in this zeolite.

  4. On the comparison of analog and digital SiPM readout in terms of expected timing performance

    International Nuclear Information System (INIS)

    Gundacker, S.; Auffray, E.; Jarron, P.; Meyer, T.; Lecoq, P.

    2015-01-01

    In time of flight positron emission tomography (TOF-PET) and in particular for the EndoTOFPET-US Project (Frisch, 2013 [1]), and other applications for high energy physics, the multi-digital silicon photomultiplier (MD-SiPM) was recently proposed (Mandai and Charbon, 2012 [2]), in which the time of every single photoelectron is being recorded. If such a photodetector is coupled to a scintillator, the largest and most accurate timing information can be extracted from the cascade of the scintillation photons, and the most probable time of positron emission determined. The readout concept of the MD-SiPM is very different from that of the analog SiPM, where the individual photoelectrons are merely summed up and the output signal fed into the readout electronics. We have developed a comprehensive Monte Carlo (MC) simulation tool that describes the timing properties of the photodetector and electronics, the scintillation properties of the crystal and the light transfer within the crystal. In previous studies we have compared MC simulations with coincidence time resolution (CTR) measurements and found good agreement within less than 10% for crystals of different lengths (from 3 mm to 20 mm) coupled to SiPMs from Hamamatsu. In this work we will use the developed MC tool to directly compare the highest possible time resolution for both the analog and digital readout of SiPMs with different scintillator lengths. The presented studies reveal that the analog readout of SiPMs with microcell signal pile-up and leading edge discrimination can lead to nearly the same time resolution as compared to the maximum likelihood time estimation applied to MD-SiPMs. Consequently there is no real preference for either a digital or analog SiPM for the sake of achieving highest time resolution. However, the best CTR in the analog SiPM is observed for a rather small range of optimal threshold values, whereas the MD-SiPM provides stable CTR after roughly 20 registered photoelectron timestamps in

  5. High current pulsed positron microprobe

    International Nuclear Information System (INIS)

    Howell, R.H.; Stoeffl, W.; Kumar, A.; Sterne, P.A.; Cowan, T.E.; Hartley, J.

    1997-01-01

    We are developing a low energy, microscopically focused, pulsed positron beam for defect analysis by positron lifetime spectroscopy to provide a new defect analysis capability at the 10 10 e + s -l beam at the Lawrence Livermore National Laboratory electron linac. When completed, the pulsed positron microprobe will enable defect specific, 3-dimensional maps of defect concentrations with sub-micron resolution of defect location. By coupling these data with first principles calculations of defect specific positron lifetimes and positron implantation profiles we will both map the identity and concentration of defect distributions

  6. Efficient Cryosolid Positron Moderators

    Science.gov (United States)

    2012-08-01

    table layout Figure 21 shows the integration of the IR spectroscopy optics with the positron Moderation and Annihilation vacuum chambers on the...Characterization of Cryogenic Moderators The application of Matrix Isolation Spectroscopy (MIS) to characterizing cryogenic solid positron ...Matrix Isolation Spectroscopy capability into our Positron Moderation apparatus, which enables spectroscopic characterization of the cryogenic

  7. Study of elastic and inelastic cross sections by positron impact on inert gases

    Science.gov (United States)

    Singh, Suvam; Naghma, Rahla; Kaur, Jaspreet; Antony, Bobby

    2018-04-01

    In this article, a modified computational method recently introduced is used for the calculation of total, positronium (Ps) formation and ionization cross sections including direct and total ionization cross sections for positron scattering from noble gases. The incident positron is assumed to have energies over a wide range from 5 eV to 5 keV. The positron-atom interaction potential is developed under an optical potential framework and the computations of cross sections for each process are performed by introducing appropriate absorption thresholds. The calculated results obtained by employing this modified approach are found to be in reasonably good agreement with most of the existing data.

  8. Positron annihilation in a metal-oxide semiconductor studied by using a pulsed monoenergetic positron beam

    Science.gov (United States)

    Uedono, A.; Wei, L.; Tanigawa, S.; Suzuki, R.; Ohgaki, H.; Mikado, T.; Ohji, Y.

    1993-12-01

    The positron annihilation in a metal-oxide semiconductor was studied by using a pulsed monoenergetic positron beam. Lifetime spectra of positrons were measured as a function of incident positron energy for a polycrystalline Si(100 nm)/SiO2(400 nm)/Si specimen. Applying a gate voltage between the polycrystalline Si film and the Si substrate, positrons implanted into the specimen were accumulated at the SiO2/Si interface. From the measurements, it was found that the annihilation probability of ortho-positronium (ortho-Ps) drastically decreased at the SiO2/Si interface. The observed inhibition of the Ps formation was attributed to an interaction between positrons and defects at the SiO2/Si interface.

  9. 22 Na positron source for annihilation positron spectroscopy

    International Nuclear Information System (INIS)

    Cimpeanu, Catalina; Craciun, L.; Dragulescu, E.; Dudu, D.; Racolta, P.M.; Voiculescu, Dana; Miron, N.

    2002-01-01

    To extend the nuclear physics applications and to perform the study of vacancy - type defects in metals, semiconductors, polymers etc., we decided to promote positron annihilation techniques. In order to achieve this goal we started a project of dedicated positron sources produced at the IFIN-HH U-120 Cyclotron. We have used the nuclear reaction 24 Mg(d,α) 22 Na and deuterons of 13 MeV energy. The paper presents the main steps of this procedure like: general conditions required for 22 NaCl sources, reactive chamber and characteristics of Mg target, parameters for the irradiation, radiochemical procedures to separate Na from Mg after the irradiation and geometrical or mechanical requirements for dedicated NaCl source for positron annihilation spectrometry. In the e + lifetime measurements the e + 'death - stop' signals are always provided by γ - quanta generated by the e + e - annihilation and the 'birth - start' signals may be obtained from 'prompt' γ - quanta emitted from the NaCl source (the 1.275 MeV photons). The 22 NaCl stock solution obtained by radiochemical separation will be kept in the sealed quartz vials in dry places and will be dropped between the studied materials before use in positron spectrometry. (authors)

  10. Quantum dynamics study on the binding of a positron to vibrationally excited states of hydrogen cyanide molecule

    Science.gov (United States)

    Takayanagi, Toshiyuki; Suzuki, Kento; Yoshida, Takahiko; Kita, Yukiumi; Tachikawa, Masanori

    2017-05-01

    We present computational results of vibrationally enhanced positron annihilation in the e+ + HCN/DCN collisions within a local complex potential model. Vibrationally elastic and inelastic cross sections and effective annihilation rates were calculated by solving a time-dependent complex-potential Schrödinger equation under the ab initio potential energy surface for the positron attached HCN molecule, [HCN; e+], with multi-component configuration interaction level (Kita and Tachikawa, 2014). We discuss the effect of vibrational excitation on the positron affinities from the obtained vibrational resonance features.

  11. Positron imaging in the evaluation of ischemia and myocardial infarction

    International Nuclear Information System (INIS)

    Goldstein, R.A.

    1985-01-01

    Positron emission tomography (PET) is a unique imaging approach since it allows quantification of regional myocardial radioactivity by virtue of its decay characteristics. Studies of regional myocardial metabolism are possible since there are positron emitting isotopes of carbon, oxygen and nitrogen that can be used to synthesize labeled fatty acids, amino acids or carbohydrate. Recent studies from the author's group have focused on Rb-82, a diffusible cation with a short half-life that is obtained from a generator and thus, has the potential for routine clinical use without a cyclotron. In this chapter, the basic principles of positron imaging and their application to imaging of acute myocardial infarction are discussed

  12. Positron Beam Characteristics at NEPOMUC Upgrade

    Science.gov (United States)

    Hugenschmidt, C.; Ceeh, H.; Gigl, T.; Lippert, F.; Piochacz, C.; Reiner, M.; Schreckenbach, K.; Vohburger, S.; Weber, J.; Zimnik, S.

    2014-04-01

    In 2012, the new neutron induced positron source NEPOMUC upgrade was put into operation at FRMII. Major changes have been made to the source which consists of a neutron-γ-converter out of Cd and a Pt foil structure for electron positron pair production and positron moderation. The new design leads to an improvement of both intensity and brightness of the mono-energetic positron beam. In addition, the application of highly enriched 113Cd as neutron-γ-converter extends the lifetime of the positron source to 25 years. A new switching and remoderation device has been installed in order to allow toggling from the high-intensity primary beam to a brightness enhanced remoderated positron beam. At present, an intensity of more than 109 moderated positrons per second is achieved at NEPOMUC upgrade. The main characteristics are presented which comprise positron yield and beam profile of both the primary and the remoderated positron beam.

  13. Positron emission tomography

    International Nuclear Information System (INIS)

    Wienhard, K.; Heiss, W.D.

    1984-01-01

    The principles and selected clinical applications of positron emission tomography are described. In this technique a chemical compound is labeled with a positron emitting isotope and its biochemical pathway is traced by coincidence detection of the two annihilation photons. The application of the techniques of computed tomography allows to reconstruct the spatial distribution of the radioactivity within a subject. The 18 F-deoxyglucose method for quantitative measurement of local glucose metabolism is discussed in order to illustrate the possibilities of positron emission tomography to record physiological processes in vivo. (orig.) [de

  14. Application of mathematical removal of positron range blurring in positron emission tomography

    International Nuclear Information System (INIS)

    Haber, S.F.; Derenzo, S.E.; Uber, D.

    1990-01-01

    The range of positrons in tissue is an important limitation to the ultimate spatial resolution achievable in positron emission tomography. In this work the authors have applied a Fourier deconvolution technique to remove range blurring in images taken by the Donner 600-crystal positron tomograph. Using phantom data, the authors have found significant improvement in the image quality and the FWHM for both 68 Ga and 82 Rb. These were successfully corrected so that the images and FWHM almost matched those of 18 F which has negligible positron range. However, statistical noise was increased by the deconvolution process and it was not practical to recover the full spatial resolution of the tomograph

  15. Positron Annihilation in Insulating Materials

    International Nuclear Information System (INIS)

    Asoka-Kumar, P; Sterne, PA

    2002-01-01

    We describe positron results from a wide range of insulating materials. We have completed positron experiments on a range of zeolite-y samples, KDP crystals, alkali halides and laser damaged SiO 2 . Present theoretical understanding of positron behavior in insulators is incomplete and our combined theoretical and experimental approach is aimed at developing a predictive understanding of positrons and positronium annihilation characteristics in insulators. Results from alkali halides and alkaline-earth halides show that positrons annihilate with only the halide ions, with no apparent contribution from the alkali or alkaline-earth cations. This contradicts the results of our existing theory for metals, which predicts roughly equal annihilation contributions from cation and anion. We also present result obtained using Munich positron microprobe on laser damaged SiO 2 samples

  16. Applications of slow positrons to cancer research: Search for selectivity of positron annihilation to skin cancer

    International Nuclear Information System (INIS)

    Jean, Y.C.; Li Ying; Liu Gaung; Chen, Hongmin; Zhang Junjie; Gadzia, Joseph E.

    2006-01-01

    Slow positrons and positron annihilation spectroscopy (PAS) have been applied to medical research in searching for positron annihilation selectivity to cancer cells. We report the results of positron lifetime and Doppler broadening energy spectroscopies in human skin samples with and without cancer as a function of positron incident energy (up to 8 μm depth) and found that the positronium annihilates at a significantly lower rate and forms at a lower probability in the samples having either basal cell carcinoma (BCC) or squamous cell carcinoma (SCC) than in the normal skin. The significant selectivity of positron annihilation to skin cancer may open a new research area of developing positron annihilation spectroscopy as a novel medical tool to detect cancer formation externally and non-invasively at the early stages

  17. Applications of slow positrons to cancer research: Search for selectivity of positron annihilation to skin cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jean, Y.C. [Department of Chemistry, University of Missouri-Kansas City, 205 Spenscer Chemistry Building, 5009 Rockhill Road, Kansas City, MO 64110 (United States)]. E-mail: jeany@umkc.edu; Li Ying [Department of Chemistry, University of Missouri-Kansas City, 205 Spenscer Chemistry Building, 5009 Rockhill Road, Kansas City, MO 64110 (United States); Liu Gaung [Department of Chemistry, University of Missouri-Kansas City, 205 Spenscer Chemistry Building, 5009 Rockhill Road, Kansas City, MO 64110 (United States); Chen, Hongmin [Department of Chemistry, University of Missouri-Kansas City, 205 Spenscer Chemistry Building, 5009 Rockhill Road, Kansas City, MO 64110 (United States); Zhang Junjie [Department of Chemistry, University of Missouri-Kansas City, 205 Spenscer Chemistry Building, 5009 Rockhill Road, Kansas City, MO 64110 (United States); Gadzia, Joseph E. [Dermatology, Department of Internal Medicine, University of Kansas Medical Center, Kansas City, KS 66103 (United States); Kansas Medical Clinic, Topeka, KS 66614 (United States)

    2006-02-28

    Slow positrons and positron annihilation spectroscopy (PAS) have been applied to medical research in searching for positron annihilation selectivity to cancer cells. We report the results of positron lifetime and Doppler broadening energy spectroscopies in human skin samples with and without cancer as a function of positron incident energy (up to 8 {mu}m depth) and found that the positronium annihilates at a significantly lower rate and forms at a lower probability in the samples having either basal cell carcinoma (BCC) or squamous cell carcinoma (SCC) than in the normal skin. The significant selectivity of positron annihilation to skin cancer may open a new research area of developing positron annihilation spectroscopy as a novel medical tool to detect cancer formation externally and non-invasively at the early stages.

  18. Positron annihilation lifetime study of low temperature irradiated metals

    Energy Technology Data Exchange (ETDEWEB)

    Kuramoto, Eiichi [Kyushu Univ., Kasuga, Fukuoka (Japan). Research Inst. for Applied Mechanics

    1997-11-01

    Positron annihilation lifetime measurements have been made for electron and neutron irradiated Fe, Fe-Cr, Fe-Cu, Fe-Si, Fe-16Cr-17Ni specimens, and isochronal annealing behaviors were obtained for these metals and alloys. It was found that vacancies start to migrate at about 200 K in Fe and form microvoids, but by the addition of small amount of alloying elements this behavior was changed depending on the alloying elements. Positron lifetime calculations were made to explain the experimental results using EAM (embedded atom method) type potential for the lattice relaxation and the atomic superposition method for the lifetime calculation. Fairly good agreements were obtained for the positron lifetime in a vacancy in Fe and other alloys. (author)

  19. Positron lifetime measurements and positron-annihilation induced auger electron spectroscpy using slow positron beams; Teisoku yodenshi bimu wo mochiita yodenshi jumyo sokutei oyobi yodenshi shometsu reiki oje denshi bunko

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, R. [Electrotechnical Lab., Tsukuba (Japan)

    1996-02-20

    Slow positron beam with less than several eV can be controlled freely such as accelerating, throttling the beam size, shortening the pulse or making pulse with short time width and so forth. These low positron beams are applied to various measurements like Doppler broadening measurement of annihilation {gamma} rays or lifetime measurement of positron, and secondary particle measurements using positron microscope, positron electron ray diffraction, flight time method and so forth. In particular, these recent years, high intensity slow positron beams were possible using accelerators like electron linac and its application is increasing. In this report, pulse shortening method for high intensity slow positron beam, and incidence energy variable positron lifetime measurement method using this slow pulsed beam and flight time type positron-annihilation-induced auger electron spectroscopy are outlined. In future, these measurements can be possible to carry out with high resolution and also with high counting rate if higher intensity monochromatic excellent positron beam than present one is produced. 31 refs., 5 figs.

  20. LLNL pure positron plasma program

    International Nuclear Information System (INIS)

    Hartley, J.H.; Beck, B.R.; Cowan, T.E.; Howell, R.H.; McDonald, J.L.; Rohatgi, R.R.; Fajans, J.; Gopalan, R.

    1995-01-01

    Assembly and initial testing of the Positron Time-of-Flight Trap at the Lawrence Livermore National Laboratory (LLNL) Increase Pulsed Positron Facility has been completed. The goal of the project is to accumulate at high-density positron plasma in only a few seconds., in order to facilitate study that may require destructive diagnostics. To date, densities of at least 6 x 10 6 positrons per cm 3 have been achieved

  1. Homotopic non-local regularized reconstruction from sparse positron emission tomography measurements

    International Nuclear Information System (INIS)

    Wong, Alexander; Liu, Chenyi; Wang, Xiao Yu; Fieguth, Paul; Bie, Hongxia

    2015-01-01

    Positron emission tomography scanners collect measurements of a patient’s in vivo radiotracer distribution. The system detects pairs of gamma rays emitted indirectly by a positron-emitting radionuclide (tracer), which is introduced into the body on a biologically active molecule, and the tomograms must be reconstructed from projections. The reconstruction of tomograms from the acquired PET data is an inverse problem that requires regularization. The use of tightly packed discrete detector rings, although improves signal-to-noise ratio, are often associated with high costs of positron emission tomography systems. Thus a sparse reconstruction, which would be capable of overcoming the noise effect while allowing for a reduced number of detectors, would have a great deal to offer. In this study, we introduce and investigate the potential of a homotopic non-local regularization reconstruction framework for effectively reconstructing positron emission tomograms from such sparse measurements. Results obtained using the proposed approach are compared with traditional filtered back-projection as well as expectation maximization reconstruction with total variation regularization. A new reconstruction method was developed for the purpose of improving the quality of positron emission tomography reconstruction from sparse measurements. We illustrate that promising reconstruction performance can be achieved for the proposed approach even at low sampling fractions, which allows for the use of significantly fewer detectors and have the potential to reduce scanner costs

  2. High resolution positron tomography

    International Nuclear Information System (INIS)

    Brownell, G.L.; Burnham, C.A.

    1982-01-01

    The limits of spatial resolution in practical positron tomography are examined. The four factors that limit spatial resolution are: positron range; small angle deviation; detector dimensions and properties; statistics. Of these factors, positron range may be considered the fundamental physical limitation since it is independent of instrument properties. The other factors are to a greater or lesser extent dependent on the design of the tomograph

  3. Positron emission tomography

    NARCIS (Netherlands)

    Paans, AMJ

    Positron Emission Tomography (PET) is a method for determining biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides as C-11, N-13, O-15 and F-18 and by measuring the annihilation radiation using a

  4. Study of SiO2-Si and metal-oxide-semiconductor structures using positrons

    Science.gov (United States)

    Leung, T. C.; Asoka-Kumar, P.; Nielsen, B.; Lynn, K. G.

    1993-01-01

    Studies of SiO2-Si and metal-oxide-semiconductor (MOS) structures using positrons are summarized and a concise picture of the present understanding of positrons in these systems is provided. Positron annihilation line-shape S data are presented as a function of the positron incident energy, gate voltage, and annealing, and are described with a diffusion-annihilation equation for positrons. The data are compared with electrical measurements. Distinct annihilation characteristics were observed at the SiO2-Si interface and have been studied as a function of bias voltage and annealing conditions. The shift of the centroid (peak) of γ-ray energy distributions in the depletion region of the MOS structures was studied as a function of positron energy and gate voltage, and the shifts are explained by the corresponding variations in the strength of the electric field and thickness of the depletion layer. The potential role of the positron annihilation technique as a noncontact, nondestructive, and depth-sensitive characterization tool for the technologically important, deeply buried interface is shown.

  5. Study of SiO2-Si and metal-oxide-semiconductor structures using positrons

    International Nuclear Information System (INIS)

    Leung, T.C.; Asoka-Kumar, P.; Nielsen, B.; Lynn, K.G.

    1993-01-01

    Studies of SiO 2 -Si and metal-oxide-semiconductor (MOS) structures using positrons are summarized and a concise picture of the present understanding of positrons in these systems is provided. Positron annihilation line-shape S data are presented as a function of the positron incident energy, gate voltage, and annealing, and are described with a diffusion-annihilation equation for positrons. The data are compared with electrical measurements. Distinct annihilation characteristics were observed at the SiO 2 -Si interface and have been studied as a function of bias voltage and annealing conditions. The shift of the centroid (peak) of γ-ray energy distributions in the depletion region of the MOS structures was studied as a function of positron energy and gate voltage, and the shifts are explained by the corresponding variations in the strength of the electric field and thickness of the depletion layer. The potential role of the positron annihilation technique as a noncontact, nondestructive, and depth-sensitive characterization tool for the technologically important, deeply buried interface is shown

  6. Perspectives on New Synthetic Curcumin Analogs and their Potential Anticancer Properties

    Science.gov (United States)

    Vyas, Alok; Dandawate, Prasad; Padhye, Subhash; Ahmad, Aamir; Sarkar, Fazlul

    2013-01-01

    Curcumin is the active component of dried rhizome of Curcuma longa, a perennial herb belonging to ginger family, cultivated extensively in south and southeastern tropical Asia. It is widely consumed in the Indian subcontinent, south Asia and Japan in traditional food recipes. Extensive research over last few decades has shown that curcumin is a potent anti-inflammatory agent with powerful therapeutic potential against a variety of cancers. It suppresses proliferation and metastasis of human tumors through regulation of various transcription factors, growth factors, inflammatory cytokines, protein kinases and other enzymes. It induces apoptotic cell death and also inhibits proliferation of cancer cells by cell cycle arrest. Pharmacokinetic data has shown that curcumin undergoes rapid metabolism leading to glucuronidation and sulfation in the liver and excretion in the feces, which accounts for its poor systemic bioavailability. The compound has, therefore, been formulated and administered using different drug delivery systems such as liposomes, micelles, polysaccharides, phospholipid complexes and nanoparticles that can overcome the limitation of bioavailability to some extent. Attempts to avoid rapid metabolism of curcumin until now have been met with limited success. This has prompted researchers to look for new synthetic curcumin analogs in order to overcome the drawbacks of limited bioavailability and rapid metabolism, and gain efficacy with reduced toxicity. In this review we provide a summarized account of novel synthetic curcumin formulations and analogs, and the recent progress in the field of cancer prevention and treatment. PMID:23116312

  7. Preliminary PET/CT Imaging with Somatostatin Analogs [68Ga]DOTAGA-TATE and [68Ga]DOTAGA-TOC.

    Science.gov (United States)

    Satpati, Drishty; Shinto, Ajit; Kamaleshwaran, K K; Sarma, Haladhar Dev; Dash, Ashutosh

    2017-12-01

    Somatostatin receptor positron emission tomography/X-ray computed tomography (SSTR-PET/CT) is a well-established technique for staging and detection of neuroendocrine tumors (NETs). Ga-68-labeled DOTA-conjugated octreotide analogs are the privileged radiotracers for diagnosis and therapeutic monitoring of NETs. Hence, we were interested in assessing the influence of promising, newer variant DOTAGA on the hydrophilicity, pharmacokinetics, and lesion pick-up of somatostatin analogs. Herein, the potential of ([ 68 Ga]DOTAGA, Tyr 3 , Thr 8 ) octreotide ([ 68 Ga]DOTAGA-TATE) and ([ 68 Ga]DOTAGA, Tyr 3 ) octreotide ([ 68 Ga]DOTAGA-TOC) as NET imaging agents has been investigated. Amenability of [ 68 Ga]DOTAGA-(TATE/TOC) to kit-type formulation has been demonstrated. Biodistribution studies were carried out in normal rats at 1 h post-injection (p.i.). [ 68 Ga]DOTAGA-(TATE/TOC) PET/CT scans were carried out in patients (70-170 MBq, 1 h p.i.) with histologically confirmed well-differentiated NETs. [ 68 Ga]DOTAGA-TATE exhibited hydrophilicity similar to [ 68 Ga]DOTA-TATE (log P = -3.51 vs -3.69) whereas [ 68 Ga]DOTAGA-TOC was more hydrophilic than [ 68 Ga]DOTA-TOC (log P = -3.27 vs -2.93). [ 68 Ga]DOTAGA-TATE and [ 68 Ga]DOTA-TATE showed almost identical blood and kidney uptake in normal rats whereas significantly fast clearance (p TOC also demonstrated rapid clearance from blood and kidneys (p TOC. The metastatic lesions in NET patients were well identified by [ 68 Ga]DOTAGA-TATE and [ 68 Ga]DOTAGA-TOC. The phenomenal analogy was observed between [ 68 Ga]DOTAGA-TATE and [ 68 Ga]DOTA-TATE as well as between [ 68 Ga]DOTAGA-TOC and [ 68 Ga]DOTA-TOC in biodistribution studies in rats. The good lesion detection ability of the two radiotracers indicates their potential as NET imaging radiotracers.

  8. Simulation of the annihilation emission of galactic positrons; Modelisation de l'emission d'annihilation des positrons Galactiques

    Energy Technology Data Exchange (ETDEWEB)

    Gillard, W

    2008-01-15

    Positrons annihilate in the central region of our Galaxy. This has been known since the detection of a strong emission line centered on an energy of 511 keV in the direction of the Galactic center. This gamma-ray line is emitted during the annihilation of positrons with electrons from the interstellar medium. The spectrometer SPI, onboard the INTEGRAL observatory, performed spatial and spectral analyses of the positron annihilation emission. This thesis presents a study of the Galactic positron annihilation emission based on models of the different interactions undergone by positrons in the interstellar medium. The models are relied on our present knowledge of the properties of the interstellar medium in the Galactic bulge, where most of the positrons annihilate, and of the physics of positrons (production, propagation and annihilation processes). In order to obtain constraints on the positrons sources and physical characteristics of the annihilation medium, we compared the results of the models to measurements provided by the SPI spectrometer. (author)

  9. Mining the bulk positron lifetime

    International Nuclear Information System (INIS)

    Aourag, H.; Guittom, A.

    2009-01-01

    We introduce a new approach to investigate the bulk positron lifetimes of new systems based on data-mining techniques. Through data mining of bulk positron lifetimes, we demonstrate the ability to predict the positron lifetimes of new semiconductors on the basis of available semiconductor data already studied. Informatics techniques have been applied to bulk positron lifetimes for different tetrahedrally bounded semiconductors in order to discover computational design rules. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  10. Excessive sensitivity of momentum densities to crystal potentials as a reason for difficulties in verifying positron enhancement theories

    Czech Academy of Sciences Publication Activity Database

    Sormann, H.; Šob, Mojmír

    363-365, - (2001), s. 612-614 ISSN 0255-5476. [International Conference on Positron Annihilation /12./. Mnichov, 06.08.2000-12.08.2000] Institutional research plan: CEZ:AV0Z2041904 Keywords : positron annihilation * electronic structure * metals Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.461, year: 2001

  11. Solvated Positron Chemistry. Competitive Positron Reactions with Halide Ions in Water

    DEFF Research Database (Denmark)

    Christensen, Palle; Pedersen, Niels Jørgen; Andersen, J. R.

    1979-01-01

    It is shown by means of the angular correlation technique that the binding of positrons to halides is strongly influenced by solvation effects. For aqueous solutions we find increasing values for the binding energies between the halide and the positron with increasing mass of the halide...

  12. Nonlinear screening effect in an ultrarelativistic degenerate electron-positron gas

    International Nuclear Information System (INIS)

    Tsintsadze, N. L.; Rasheed, A.; Shah, H. A.; Murtaza, G.

    2009-01-01

    Nonlinear screening process in an ultrarelativistic degenerate electron-positron gas has been investigated by deriving a generalized nonlinear Poisson equation for the electrostatic potential. In the simple one-dimensional case, the nonlinear Poisson equation leads to Debye-like (Coulomb-like) solutions at distances larger (less) than the characteristic length. When the electrostatic energy is larger than the thermal energy, this nonlinear Poisson equation converts into the relativistic Thomas-Fermi equation whose asymptotic solution in three dimensions shows that the potential field goes to zero at infinity much more slowly than the Debye potential. The possibility of the formation of a bound state in electron-positron plasma is also indicated. Further, it is investigated that the strong spatial fluctuations of the potential field may reduce the screening length and that the root mean square of this spatial fluctuating potential goes to zero for large r rather slowly as compared to the case of the Debye potential.

  13. Development of a transmission positron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Matsuya, M., E-mail: matsuya@jeol.co.jp [JEOL Ltd., 1-2 Musashino, 3-Chome, Akishima, Tokyo 196-8558 (Japan); Jinno, S. [Department of Applied Chemistry, Chiba University, Yayoi, Inage, Chiba, Chiba 263-8552 (Japan); Ootsuka, T.; Inoue, M. [JEOL Ltd., 1-2 Musashino, 3-Chome, Akishima, Tokyo 196-8558 (Japan); Kurihara, T. [High Energy Accelerator Research Organization, Oho, Tsukuba, Ibaraki 305-0801 (Japan); Doyama, M.; Inoue, M. [Teikyo University of Science and Technology, Uenohara, Yamanashi 409-0913 (Japan); Fujinami, M. [Department of Applied Chemistry, Chiba University, Yayoi, Inage, Chiba, Chiba 263-8552 (Japan)

    2011-07-21

    A practical transmission positron microscope (TPM) JEM-1011B has been developed to survey differences in the interaction of positron and electron beams with materials, and is installed in the Slow Positron Facility of High Energy Accelerator Research Organization (KEK). The TPM can share positron and electron beams, and can also be used as a transmission electron microscope (TEM). Positron transmission images up to magnification 10,000x (resolution: 50 nm) and positron diffraction patterns up to 044 family were successfully obtained by the TPM comparing them with those of electrons. The differences in material transmittances for both beams have been measured, and can be explained by the calculated results of the Monte Carlo simulation code PENELOPE-2008.

  14. Zinc-phosphate nanoparticles with reversibly attached TNF-α analogs: an interesting concept for potential use in active immunotherapy

    International Nuclear Information System (INIS)

    Hribar, Gorazd; Žnidaršič, Andrej; Bele, Marjan; Maver, Uroš; Caserman, Simon; Gaberšček, Miran; Gaberc-Porekar, Vladka

    2011-01-01

    The authors’ intention was to prepare nanometer-sized zinc-phosphate nanoparticles that would be capable of binding histidine-rich TNF-α analogs onto their surface via a coordinative bond. Zinc-phosphate nanoparticles with a size of around 60 nm were prepared by a wet precipitation method and characterized using SEM, EDX, XRD, and DLS. First, BSA was bound as a testing protein, afterward two TNF-α analogs with decreased activity were bound to the described nanoparticles. The efficiency of binding and the existence of coordinative bond were confirmed with SDS-PAGE analysis. During binding, particle storage, and release experiments, the prepared TNF-α analogs retained their biological activity—hence the epitopes necessary for formation of antibodies stayed intact. The particle size did not change within a period of 2 weeks. No significant agglomeration was observed, the particles could be quickly dispersed in ultrasound. The present nanoparticles and the general approach of coordinative binding are widely applicable for natural and engineered histidine-rich proteins. The nanoparticles bearing appropriate TNF-α analogs could also be potentially used for active immunotherapy to tackle the chronic inflammatory diseases associated with pathogenically elevated levels of TNF-α.

  15. Positron annihilation microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Canter, K F [Brandeis Univ., Waltham, MA (United States)

    1997-03-01

    Advances in positron annihilation microprobe development are reviewed. The present resolution achievable is 3 {mu}m. The ultimate resolution is expected to be 0.1 {mu}m which will enable the positron microprobe to be a valuable tool in the development of 0.1 {mu}m scale electronic devices in the future. (author)

  16. Positron lifetimes in deformed copper

    International Nuclear Information System (INIS)

    Hinode, Kenji; Tanigawa, Shoichiro; Doyama, Masao

    1976-01-01

    Positron lifetime measurements were performed for Cu samples with different densities of lattice defects. The lifetime spectra were successfully resolved into two components with the help of the well established analysis program. Obtained results were quite consistent with those expected from the trapping model. The positron trapping mechanism from free to trapped states and the initial condition of the model were especially checked. Deduced values obtained for tau sub(c) (lifetime of free positrons) and tau sub(t) (lifetime of trapped positrons) were 122+-5 psec and 176+-5 psec, respectively. (auth.)

  17. Positron emission tomography in malignant haematological disease

    NARCIS (Netherlands)

    Schot, Bartholomeus Wilhelmus

    2007-01-01

    Positron emission tomography (PET) is a diagnostic technique with a promising role especially in the haemato-oncology. Although its use in the management ; of malignant lymphoma seems to be established already, much about the true potential and drawbacks of FDG-PET in this disease are still unknown.

  18. Positron annihilation near fractal surfaces

    International Nuclear Information System (INIS)

    Lung, C.W.; Deng, K.M.; Xiong, L.Y.

    1991-07-01

    A model for positron annihilation in the sub-surface region near a fractal surface is proposed. It is found that the power law relationship between the mean positron implantation depth and incident positron energy can be used to measure the fractal dimension of the fractal surface in materials. (author). 10 refs, 2 figs

  19. Positron emission tomography in oncology. Council on Scientific Affairs

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This report describes the current and potential uses of positron emission tomography in clinical medicine and research related to oncology. Assessment will be possible of metabolism and physiology of tumors and their effects on adjacent tissues. Specific probes are likely to be developed for target sites on tumors, including monoclonal antibodies and specific growth factors that recognize tumors. To date, most oncological applications of positron emission tomography tracers have been qualitative; in the future, quantitative metabolic measurements should aid in the evaluation of tumor biology and response to treatment. 41 references

  20. Design and synthesis of enantiomerically enriched, radiolabeled MK-801 analogs as potential radiotracers for imaging and autoradiographic studies of the NMDA receptor-ion channel complex

    International Nuclear Information System (INIS)

    Eng, W.S.; Burns, H.D.; Gibson, R.E.; Ransom, R.W.; Thorpe, H.; Fioravanit, C.; Britcher, S.F.; Magill, C.A.; Solomon, H.F.; Dannals, R.F.; Wilson, A.A.; Ravert, H.T.; Wagner, H.N.

    1989-01-01

    MK-801 is a potent, non-competitive antagonist for the N-methyl-D-asspartate (NMDA) receptor-ion channel complex. This complex is though to be involved in nerve cell damage in stroke patients when excess calcium is released through the activated channel. A thorough understanding of drug interactions with the NMDA receptor complex could lead to improved therapy for reducing hypoxic-ischemic neuronal injuries in stroke patients. Based on the results of extensive structure-activity studies, the authors have developed several enantiomerically enriched, radiolabeled analogs of MK-801, including: 3-1231-MK-801 for Single Photon Emission Computed tomography (SPECT); 3-1251-MK-801 for in-vivo and in-vitro autoradiography; 8-11C-MeO-MK-801 for Positron Emission Tomography (PET). Details of the synthesis of these radiotracers and their application to both in-vitro and in-vivo studies are described

  1. High energy positron imaging

    International Nuclear Information System (INIS)

    Chen Shengzu

    2003-01-01

    The technique of High Energy Positron Imaging (HEPI) is the new development and extension of Positron Emission Tomography (PET). It consists of High Energy Collimation Imaging (HECI), Dual Head Coincidence Detection Imaging (DHCDI) and Positron Emission Tomography (PET). We describe the history of the development and the basic principle of the imaging methods of HEPI in details in this paper. Finally, the new technique of the imaging fusion, which combined the anatomical image and the functional image together are also introduced briefly

  2. Positron total scattering cross-sections for alkali atoms

    Science.gov (United States)

    Sinha, Nidhi; Singh, Suvam; Antony, Bobby

    2018-01-01

    Positron-impact total scattering cross-sections for Li, Na, K, Rb, Cs and Fr atoms are calculated in the energy range from 5-5000 eV employing modified spherical complex optical potential formalism. The main aim of this work is to apply this formalism to the less studied positron-target collision systems. The results are compared with previous theoretical and experimental data, wherever available. In general, the present data show overall agreement and consistency with other results. Furthermore, we have done a comparative study of the results to investigate the effect of atomic size on the cross-sections as we descend through the group in the periodic table. We have also plotted a correlation graph of the present total cross-sections with polarizability and number of target electrons. The two correlation plots confirm the credibility and consistency of the present results. Besides, this is the first theoretical attempt to report positron-impact total cross-sections of alkali atoms over such a wide energy range.

  3. Positron and positronium annihilation in silica-based thin films studied by a pulsed positron beam

    International Nuclear Information System (INIS)

    Suzuki, R.; Ohdaira, T.; Kobayashi, Y.; Ito, K.; Shioya, Y.; Ishimaru, T.

    2003-01-01

    Positron and positronium annihilation in silica-based thin films has been investigated by means of measurement techniques with a monoenergetic pulsed positron beam. The age-momentum correlation study revealed that positron annihilation in thermally grown SiO 2 is basically the same as that in bulk amorphous SiO 2 while o-Ps in the PECVD grown SiCOH film predominantly annihilate with electrons of C and H at the microvoid surfaces. We also discuss time-dependent three-gamma annihilation in porous low-k films by two-dimensional positron annihilation lifetime spectroscopy

  4. Positron astronomy with SPI/INTEGRAL

    International Nuclear Information System (INIS)

    Weidenspointner, G.; Diehl, R.; Strong, A.; Weidenspointner, G.; Skinner, G.K.; Skinner, G.K.; Jean, P.; Knoedlseder, J.; Von Ballmoos, P.; Cordier, B.; Schanne, S.; Winkler, C.

    2008-01-01

    We provide an overview of positron astronomy results that have been obtained using the INTEGRAL spectrometer SPI, and discuss their implications for the still mysterious origin of positrons in our Galaxy. It has long been known that the 511 keV positron annihilation emission is strongest from the central region of our Galaxy. Recently, it has been discovered with the SPI spectrometer that the weaker 511 keV line emission from the inner Galactic disk appears to be asymmetric, with the emission to the west of the Galactic center being about twice as strong than that to the east. This distribution of positron annihilation resembles that of low mass X-ray binaries as observed with the INTEGRAL imager IBIS at hard X-ray energies, suggesting that these systems could provide a significant portion of the positrons in our Galaxy. In addition, the spectrometer SPI has permitted unprecedented spectroscopy of annihilation radiation from the bulge and disk regions of the Galaxy, which commences to yield important insights into the conditions of the medium in which the positrons annihilate. (authors)

  5. Dependence of isobar-analog state properties on variable part of Coulomb potential

    International Nuclear Information System (INIS)

    Dzhafarov, I.G.; Kuliev, A.A.; Salamov, D.I.

    1986-01-01

    Within the framework of the self-consistent approach and with the method of strength functions the fragmentation of isobar-analog state (IAS) properties for all isobarie 0 + -states is investigated. Microscopic values of IAS energy, matrix elements of allowed and forbidden Fermi transitions as well as isospin impurity values in ground states of parent nuclei are obtained. Numerical calculations carried out for 42 Ca 42 Sc, 48 Ca 48 Sc, 64 Zn 64 Ga, 66 Zn 66 Ga, 90 Zr 90 Nb, 208 Pb 208 Bi isobaric nuclei with Woods-Saxon potential, are compared with predictions of different approches and experiment. The developed model by the authors permits to describe sufficiently well the experimental data

  6. Positron implantation profile in kapton

    International Nuclear Information System (INIS)

    Plotkowski, K.; Panek, T.J.; Kansj, J.

    1988-01-01

    Measurements of positrons' implantation profile were made with geometry as in the majority of PAT experiments, making use of the difference in values of mean lifetimes of positrons in the absorber and in the detector. The function describing the absorption of positrons in the absorber taking into account measurement geometry was fitted to the experimental data. The correction to the exponential relation occurring in this function is the dominating factor for small thicknesses of the absorber. In this analysis various values of positrons' backscatter coefficients of the nickel and of the kapton were also taken into account

  7. The Positron-Electron Correlation Energy In ZnO Calculated With The Modified Single Wave Function Of Positron

    International Nuclear Information System (INIS)

    Chau Van Tao; Trinh Hoa Lang; Le Hoang Chien; Nguyen Huu Loc; Nguyen Anh Tuan

    2011-01-01

    Positron-electron correlation energy of the ZnO - positron system is studied on assumption that positron binds with the outer shell electrons of Zinc and Oxygen to form the pseudo ZnO - positron molecule before it annihilates with one of these electrons. In this work, the single wave function for positron is form by LCAO approximation and is modified according to the principle of linear superposition, and by using Variational Quantum Monte Carlo method (VQMC) [7] the correlation energy of this system is estimated with the value E c e-p = - 9.3 ± 1.1 eV. In the theoretical aspect it turns out that this result is more reasonable and closer to those of other methods [3] than the one which is done without modifying the wave function of positron [1]. To confirm this legitimate approach, however, the further calculations of positron annihilation rate in ZnO have to be carried out in our next work. (author)

  8. One-step synthesis of an {sup 18}F-labeled boron-derived methionine analog. A substitute for {sup 11}C-methionine?

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zhen; Lan, Xiaoli [Huazhong University of Science and Technology, Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Wuhan (China); Huazhong University of Science and Technology, Hubei Key Laboratory of Molecular Imaging, Union Hospital, Tongji Medical College, Wuhan (China); Ehlerding, Emily B. [University of Wisconsin - Madison, Department of Medical Physics, Madison, WI (United States); Cai, Weibo [University of Wisconsin - Madison, Department of Medical Physics, Madison, WI (United States); University of Wisconsin - Madison, Department of Radiology, Madison, WI (United States); University of Wisconsin - Madison, Carbone Cancer Center, Madison, WI (United States)

    2018-04-15

    Amino acid-based tracers have been extensively investigated for positron emission tomography (PET) imaging of brain tumors, and {sup 11}C-methionine ({sup 11}C-MET) is one of the most extensively investigated. However, widespread clinical use of {sup 11}C-MET is challenging due to the short half-life of {sup 11}C and low radiolabeling yield. In this issue of the European Journal of Nuclear Medicine and Molecular Imaging, Yang and colleagues report an {sup 18}F-labeled boron-derived methionine analog, {sup 18}F-B-MET, as a potential substitute for {sup 11}C-MET in PET imaging of glioma. The push-button synthesis, highly efficient radiolabeling, and good imaging performance in glioma models make this tracer a promising candidate for future clinical translation. (orig.)

  9. A Southern African positron beam

    International Nuclear Information System (INIS)

    Britton, D.T.; Haerting, M.; Teemane, M.R.B.; Mills, S.; Nortier, F.M.; Van der Walt, T.N.

    1997-01-01

    The first stage of a state of the art positron beam, being constructed at the University of Cape Town, is currently being brought into operation. This is the first positron beam on the African continent, as well as being the first positron beam dedicated to solid and surface studies in the southern hemisphere. The project also contains a high proportion of local development, including the encapsulated 22 Na positron source developed by our collaboration. Novel features in the design include a purely magnetic in-line deflector, working in the solenoidal guiding field, to eliminate unmoderated positrons and block the direct line of sight to the source. A combined magnetic projector and single pole probe forming lens is being implemented in the second phase of construction to achieve a spot size of 10 μm without remoderation

  10. Threshold Law For Positron Impact Ionization of Atoms

    International Nuclear Information System (INIS)

    Ihra, W.; Mota-Furtado, F.; OMahony, P.F.; Macek, J.H.; Macek, J.H.

    1997-01-01

    We demonstrate that recent experiments for positron impact ionization of He and H 2 can be interpreted by extending Wannier theory to higher energies. Anharmonicities in the expansion of the three-particle potential around the Wannier configuration give rise to corrections in the threshold behavior of the breakup cross section. These corrections are taken into account perturbatively by employing the hidden crossing theory. The resulting threshold law is σ(E)∝E 2.640 exp[ -0.73√(E)] . The actual energy range for which the Wannier law is valid is found to be smaller for positron impact ionization than for electron impact ionization. copyright 1997 The American Physical Society

  11. Positron Transport and Annihilation in the Galactic Bulge

    Directory of Open Access Journals (Sweden)

    Fiona Helen Panther

    2018-03-01

    Full Text Available The annihilation of positrons in the Milky Way Galaxy has been observed for ∼50 years; however, the production sites of these positrons remains hard to identify. The observed morphology of positron annihilation gamma-rays provides information on the annihilation sites of these Galactic positrons. It is understood that the positrons responsible for the annihilation signal originate at MeV energies. The majority of sources of MeV positrons occupy the star-forming thin disk of the Milky Way. If positrons propagate far from their sources, we must develop accurate models of positron propagation through all interstellar medium (ISM phases in order to reveal the currently uncertain origin of these Galactic positrons. On the other hand, if positrons annihilate close to their sources, an alternative source of MeV positrons with a distribution that matches the annihilation morphology must be identified. In this work, I discuss the various models that have been developed to understand the origin of the 511 keV line from the direction of the Galactic bulge, and the propagation of positrons in the ISM.

  12. Calculation of total cross sections for electron and positron scattering on sodium and potassium

    International Nuclear Information System (INIS)

    McCarthy, I.E.; Ratnavelu, K.; Zhou, Y.

    1993-02-01

    Total cross sections for electron and positron scattering on sodium and potassium are calculated at various energies and compared with experiment. The method use is the coupled-channels-optical method with the equivalent-local polarisation potential, which takes all channels into account. For electrons the calculations are checked by comparison with coupled-channels-optical calculations using a detailed polarisation potential that makes only one approximation, that of weak coupling in the ionisation space. The polarisation potential for positrons includes effects of ionisation and positronium formation. 13 refs., 2 tabs

  13. Multi-targeting Andrographolide and its Natural Analogs as Potential Therapeutic Agents.

    Science.gov (United States)

    Kishore, V; Yarla, Nagendra Sastry; Bishayee, Anupam; Putta, Swathi; Malla, Ramarao; Neelapu, Nageswara Rao Reddy; Challa, Surekha; Das, Subhasish; Shiralgi, Yallappa; Hegde, Gurumurthy; Dhananjaya, Bhadrapura Lakkappa

    2017-01-01

    Andrographis paniculata (A. paniculata) is a medicinal plant used in the Indian and Chinese traditional medicinal systems for its various beneficial properties of therapeutics. This is due to the presence of a diterpene lactone called 'andrographolide'. Several biological activities like antiinflammatory, antitumour, anti-hyperglycaemic, anti-fertility, antiviral, cardio protective and hepatoprotective properties are attributed to andrographolide and its natural analogs. The studies have shown that not only this diterpene lactone (andrographolide), but also other related terpenoid analogs from A. paniculata could be exploited for disease prevention due to their structural similarity with diverse pharmacological activities. Several scientific groups are trying to unveil the underlying mechanisms involved in these biological actions brough aout by andrographolide and its analogs. This review aims at giving an overview on the therapeutical and/or pharmacological activities of andrographolide and its derivatives and also exemplify the underlying mechanisms involved. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  14. Serotonin synthesis studied with positron emission tomography, (PET)

    DEFF Research Database (Denmark)

    Honoré, Per Gustaf Hartvig; Lundquist, Pinelopi

    Positron emission tomography (PET) has the potential to study the biosynthesis and release of serotonin (5HT) at brain serotonergic neurons. PET requires probe compounds with specific attributes to enable imaging and quantification of biological processes. This section focuses on probes to measure...

  15. PF slow positron source

    International Nuclear Information System (INIS)

    Shirakawa, A.; Enomoto, A.; Kurihara, T.

    1993-01-01

    A new slow-positron source is under construction at the Photon Factory. Positrons are produced by bombarding a tantalum rod with high-energy electrons; they are moderated in multiple tungsten vanes. We report here the present status of this project. (author)

  16. Proposal for an intense slow positron beam facility at PSI

    International Nuclear Information System (INIS)

    Waeber, W.B.; Taqqu, D.; Zimmermann, U.; Solt, G.

    1990-05-01

    In the domain of condensed matter physics and materials sciences monoenergetic slow positrons in the form of highest intensity beams are demonstrated to be extreamly useful and considered to be highly needed. This conclusion has been reached and the scientific relevance of the positron probe has been highlighted at an international workshop in November 1989 at PSI, where the state of the art and the international situation on slow positron beams, the fields of application of intense beams and the technical possibilities at PSI for installing intense positron sources have been evaluated. The participants agreed that a high intensity beam as a large-scale user facility at PSI would serve fundamental and applied research. The analysis of responses given by numerous members of a widespread positron community has revealed a large research potential in the domain of solid-state physics, atomic physics and surface, thin-film and defect physics, for example. The excellent feature of slow positron beams to be a suitable probe also for lattice defects near surfaces or interfaces has attracted the interest not only of science but also of industry.In this report we propose the installation of an intense slow positron beam facility at PSI including various beam lines of different qualities and based on the Cyclotron production of β + emitting source material and on a highest efficiency moderation scheme which exceeds standard moderation efficiencies by two orders of magnitude. In its proposed form, the project is estimated to be realizable in the nineties and costs will amount to between 15 and 20 MSFr. (author) 10 figs., 6 tabs., 78 refs

  17. An emergent approach to analogical inference

    Science.gov (United States)

    Thibodeau, Paul H.; Flusberg, Stephen J.; Glick, Jeremy J.; Sternberg, Daniel A.

    2013-03-01

    In recent years, a growing number of researchers have proposed that analogy is a core component of human cognition. According to the dominant theoretical viewpoint, analogical reasoning requires a specific suite of cognitive machinery, including explicitly coded symbolic representations and a mapping or binding mechanism that operates over these representations. Here we offer an alternative approach: we find that analogical inference can emerge naturally and spontaneously from a relatively simple, error-driven learning mechanism without the need to posit any additional analogy-specific machinery. The results also parallel findings from the developmental literature on analogy, demonstrating a shift from an initial reliance on surface feature similarity to the use of relational similarity later in training. Variants of the model allow us to consider and rule out alternative accounts of its performance. We conclude by discussing how these findings can potentially refine our understanding of the processes that are required to perform analogical inference.

  18. Positron spectroscopy of 2D materials using an advanced high intensity positron beam

    Science.gov (United States)

    McDonald, A.; Chirayath, V.; Lim, Z.; Gladen, R.; Chrysler, M.; Fairchild, A.; Koymen, A.; Weiss, A.

    An advanced high intensity variable energy positron beam(~1eV to 20keV) has been designed, tested and utilized for the first coincidence Doppler broadening (CDB) measurements on 6-8 layers graphene on polycrystalline Cu sample. The system is capable of simultaneous Positron annihilation induced Auger electron Spectroscopy (PAES) and CDB measurements giving it unparalleled sensitivity to chemical structure at external surfaces, interfaces and internal pore surfaces. The system has a 3m flight path up to a micro channel plate (MCP) for the Auger electrons emitted from the sample. This gives a superior energy resolution for PAES. A solid rare gas(Neon) moderator was used for the generation of the monoenergetic positron beam. The positrons were successfully transported to the sample chamber using axial magnetic field generated with a series of Helmholtz coils. We will discuss the PAES and coincidence Doppler broadening measurements on graphene -Cu sample and present an analysis of the gamma spectra which indicates that a fraction of the positrons implanted at energies 7-60eV can become trapped at the graphene/metal interface. This work was supported by NSF Grant No. DMR 1508719 and DMR 1338130.

  19. Positron depth profiling

    International Nuclear Information System (INIS)

    Coleman, P.

    2001-01-01

    Wide-ranging studies of defects below the surface of semiconductor structures have been performed at the University of Bath, in collaboration with the University of Surrey Centre for Ion Beam Applications and with members of research teams at a number of UK universities. Positron implantation has been used in conjunction with other spectroscopies such as RBS-channeling and SIMS, and electrical characterisation methods. Research has ranged from the development of a positron-based technique to monitor the in situ annealing of near-surface open-volume defects to the provision of information on defects to comprehensive diagnostic investigations of specific device structures. We have studied Si primarily but not exclusively; e.g., we have investigated ion-implanted SiC and SiO 2 /GaAs structures. Of particular interest are the applications of positron annihilation spectroscopy to ion-implanted semiconductors, where by linking ion dose to vacancy-type defect concentration one can obtain information on ion dose and uniformity with a sensitivity not achievable by standard techniques. A compact, user-friendly positron beam system is currently being developed at Bath, in collaboration with SCRIBA, with the intention of application in an industrial environment. (orig.)

  20. Positron annihilation induced Auger electron spectroscopy and its implementation at accelerator based low energy positron factories

    International Nuclear Information System (INIS)

    Weiss, A.; Koeymen, A.R.; Mehl, D.; Lee, K.H.; Yang Gimo; Jensen, K.

    1991-01-01

    Positron annihilation induced auger electron spectroscopy (PAES) makes use of a beam of low energy positrons to excite Auger transitions by annihilating core electrons. The large secondary electron background usually present in Auger spectra can be eliminated by setting the positron beam energy well below the Auger electron energy. This allows true Auger lineshapes to be obtained. Further, because the positron is localized just outside the surface before it annihilates, PAES is extremely sensitive to the topmost atomic layer. Recent PAES results obtained at the University of Texas at Arlington will be presented. In addition, the use of high resolution energy analyzers with multichannel particle detection schemes to prevent problems due to the high data rates associated with accelerator based positron beams will be discussed. (orig.)

  1. Positron lifetime calculation for defects and defect clusters in graphite

    International Nuclear Information System (INIS)

    Onitsuka, T.; Ohkubo, H.; Takenaka, M.; Tsukuda, N.; Kuramoto, E.

    2000-01-01

    Calculations of positron lifetime have been made for vacancy type defects in graphite and compared with experimental results. Defect structures were obtained in a model graphite lattice after including relaxation of whole lattice as determined by the molecular dynamics method, where the interatomic potential given by Pablo Andribet, Dominguez-Vazguez, Mari Carmen Perez-Martin, Alonso, Jimenez-Rodriguez [Nucl. Instrum. and Meth. 115 (1996) 501] was used. For the defect structures obtained via lattice relaxation positron lifetime was calculated under the so-called atomic superposition method. Positron lifetimes 204 and 222 ps were obtained for the graphite matrix and a single vacancy, respectively, which can be compared with the experimental results 208 and 233 ps. For planar vacancy clusters, e.g., vacancy loops, lifetime calculation was also made and indicated that lifetime increases with the number of vacancies in a cluster. This is consistent with the experimental result in the region of higher annealing temperature (above 1200 deg. C), where the increase of positron lifetime is seen, probably corresponding to the clustering of mobile vacancies

  2. Nonlinear positron acoustic solitary waves

    International Nuclear Information System (INIS)

    Tribeche, Mouloud; Aoutou, Kamel; Younsi, Smain; Amour, Rabia

    2009-01-01

    The problem of nonlinear positron acoustic solitary waves involving the dynamics of mobile cold positrons is addressed. A theoretical work is presented to show their existence and possible realization in a simple four-component plasma model. The results should be useful for the understanding of the localized structures that may occur in space and laboratory plasmas as new sources of cold positrons are now well developed.

  3. Positron emission tomography. Basic principles

    International Nuclear Information System (INIS)

    Rodriguez, Jose Luis; Massardo, Teresa; Gonzalez, Patricio

    2001-01-01

    The basic principles of positron emission tomography (PET) technique are reviewed. lt allows to obtain functional images from gamma rays produced by annihilation of a positron, a positive beta particle. This paper analyzes positron emitters production in a cyclotron, its general mechanisms, and the various detection systems. The most important clinical applications are also mentioned, related to oncological uses of fluor-l8-deoxyglucose

  4. Compressive effect of the magnetic field on the positron range in commonly used positron emitters simulated using Geant4

    Science.gov (United States)

    Li, Chong; Cao, Xingzhong; Liu, Fuyan; Tang, Haohui; Zhang, Zhiming; Wang, Baoyi; Wei, Long

    2017-11-01

    The compressive effect of a magnetic field on the positron range from commonly used positron emitters in PET (Positron Emission Tomography) was simulated using the Geant4 toolkit with H2O as the environmental material. The compression of the positron range, which was different in the directions parallel and perpendicular to the magnetic field, showed finite final variation of relative change rate versus the magnetic field. The variation greatly depended on the positron-emission energy spectrum in the same medium. Furthermore, the volume of the positron annihilation point was dramatically compressed as the magnetic field was set in the range of 3-6T. It was more prominent for 82Rb , which is generally used as a positron source in PET technology.

  5. Positron annihilation studies of mesoporous silica films using a slow positron beam

    International Nuclear Information System (INIS)

    He Chunqing; Muramatsu, Makoto; Ohdaira, Toshiyuki; Kinomura, Atsushi; Suzuki, Ryoichi; Ito, Kenji; Kabayashi, Yoshinori

    2006-01-01

    Positron annihilation lifetime spectra were measured for mesoporous silica films, which were synthesized using triblock copolymer (EO 106 PO 70 EO 106 ) as a structure-directing agent. Different positron lifetime spectra for the deposited and calcined films indicated the formation of meso-structure after calcination, which was confirmed by Fourier transform infrared (FTIR) spectra and field emission-scanning electron microscopy (FE-SEM) observation. Open porosity or pore interconnectivity of a silica film might be evaluated by a two-dimensional positron annihilation lifetime spectrum of an uncapped film. Pore sizes and their distributions in the silica films were found to be affected by thermal treatments

  6. Mutagenic activity of a fluorinated analog of the beta-adrenoceptor ligand carazolol in the Ames test

    Energy Technology Data Exchange (ETDEWEB)

    Doze, P. E-mail: P.Doze@pet.azg.nl; Elsinga, P.H.; Vries, E.F.J. de; Waarde, A. van; Vaalburg, W

    2000-04-01

    S-1'[{sup 18}F]-Fluorocarazolol (FCAR) is a fluorinated analog of the nonmutagenic beta-blocker carazolol (CAR). In former studies FCAR proved to be suitable for quantification of beta-adrenoceptors in vivo with positron emission tomography (PET). We report here that FCAR displays no acute toxicity in either rats or mice. However, FCAR induces a strong dose-related increase in the number of revertants in the Ames test. We conclude that FCAR yields mutagenic activity as measured by the Ames test.

  7. Positron annihilation spectroscopy

    International Nuclear Information System (INIS)

    Sundar, C.S.; Viswanathan, B.

    1996-01-01

    An overview of positron annihilation spectroscopy, the experimental techniques and its application to studies on defects and electronic structure of materials is presented. The scope of this paper is to present the requisite introductory material, that will enable a better appreciation of the subsequent specialized articles on the applications of positron annihilation spectroscopy to investigate various problems in materials science. (author). 31 refs., 3 figs

  8. Positron annihilation and tribological studies of nano-embedded Al ...

    Indian Academy of Sciences (India)

    Administrator

    Positron annihilation studies of aluminium alloys with nanodispersions of insoluble elements, i.e.,. In, Sn, Pb and Au ... potential objects of different studies and applications. ... dence Doppler broadening spectroscopy is the high sensi- tivity to ...

  9. Cosmological Implications of the Electron-Positron Aether

    Science.gov (United States)

    Rothwarf, Allen

    1997-04-01

    An aether is not prohibited on theoretical nor experimental grounds; only a credible physical model for it is lacking.By assuming that the particles and anti-particles created during the "big-bang" origin of the universe have not annihilated one another, but instead, form a bound state plasma, we have a model for a real aether.This aether is dominated by electron-positron pairs at very high density(10**30/cm3),in close analogy with electron-hole droplets formed in laser irradiated semiconductors. The Fermi velocity of this plasma is the speed of light, and the plasma expands at this speed. This gives results for the expanding universe in agreement with the Einstein-deSitter result for a universe dominated by radiation.The speed of light varies with time as do the other fundamental constants.This leads to an alternate explanation for cosmological redshifts. Independent,mini big bangs can occur and account for observed anomalous redshifts. The model can be tested using LIGO apparatus.

  10. Positron Studies of Oxide-Semiconductor Structures

    OpenAIRE

    Uedono , A.; Wei , L.; Kawano , T.; Tanigawa , S.; Suzuki , R.; Ohgaki , H.; Mikado , T.

    1995-01-01

    The annihilation characteristics of positrons in SiO2 films grown on Si substrates were studied by using monoenergetic positron beams. Doppler broadening profiles of the annihilation radiation and lifetime spectra of positrons were measured as a function of incident positron energy for SiO2/Si structures fabricated by various oxidation techniques. From the measurements, it was found that the formation probability of positronium (Ps) atoms in SiO2 films strongly depends on the growth condition...

  11. Depth-dependent positron annihilation in different polymers

    Energy Technology Data Exchange (ETDEWEB)

    Yang, J.; Zhang, P.; Cheng, G.D.; Li, D.X.; Wu, H.B.; Li, Z.X.; Cao, X.Z. [Key Laboratory of Nuclear Analysis Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, No. 19 Yuquan Lu, Beijing 100049 (China); Jia, Q.J. [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, No. 19 Yuquan Lu, Beijing 100049 (China); Yu, R.S. [Key Laboratory of Nuclear Analysis Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, No. 19 Yuquan Lu, Beijing 100049 (China); Wang, B.Y., E-mail: wangboy@ihep.ac.cn [Key Laboratory of Nuclear Analysis Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, No. 19 Yuquan Lu, Beijing 100049 (China)

    2013-09-01

    Depth-dependent positron annihilation Doppler broadening measurements were conducted for polymers with different chemical compositions. Variations of the S parameter with respect to incident positron energy were observed. For pure hydrocarbons PP, HDPE and oxygen-containing polymer PC, S parameter rises with increasing positron implantation depth. While for PI and fluoropolymers like PTFE, ETFE and PVF, S parameter decreases with higher positron energy. For chlorine-containing polymer PVDC, S parameter remains nearly constant at all incident positron energies. It is suggested that these three variation trends are resulted from a competitive effect between the depth-dependent positronium formation and the influence of highly electronegative atoms on positron annihilation characteristics.

  12. Simulation of the annihilation emission of galactic positrons; Modelisation de l'emission d'annihilation des positrons Galactiques

    Energy Technology Data Exchange (ETDEWEB)

    Gillard, W

    2008-01-15

    Positrons annihilate in the central region of our Galaxy. This has been known since the detection of a strong emission line centered on an energy of 511 keV in the direction of the Galactic center. This gamma-ray line is emitted during the annihilation of positrons with electrons from the interstellar medium. The spectrometer SPI, onboard the INTEGRAL observatory, performed spatial and spectral analyses of the positron annihilation emission. This thesis presents a study of the Galactic positron annihilation emission based on models of the different interactions undergone by positrons in the interstellar medium. The models are relied on our present knowledge of the properties of the interstellar medium in the Galactic bulge, where most of the positrons annihilate, and of the physics of positrons (production, propagation and annihilation processes). In order to obtain constraints on the positrons sources and physical characteristics of the annihilation medium, we compared the results of the models to measurements provided by the SPI spectrometer. (author)

  13. Experimentation with low-energy positron beams

    International Nuclear Information System (INIS)

    Mills, A.P. Jr.

    1983-01-01

    The capability of studying the interactions of positrons with surfaces has recently been exploited by using ultra-high-vacuum techniques. The result has been a new understanding of how positrons interact with surfaces and because of this we are now able to make much stronger fluxes of slow positrons. The higher beam strengths in turn are opening up new possibilities for experimentation on surfaces and solids and for studying the atomic physics of positronium and positron-molecule scattering at low energies. The lectures are intended to review some of the history of this subject and to outline the present state of our knowledge of experimentation with low-energy positron beams. (orig./TW)

  14. Positron annihilation in vitreous silica glasses

    International Nuclear Information System (INIS)

    Uedono, Akira; Tanigawa, Shoichiro

    1993-01-01

    The annihilation characteristics of positrons in vitreous silica glasses (v-SiO 2 ) were studied by measurements of two-dimensional angular correlation of positron annihilation radiations and positron lifetime spectra. From the measurements, it was found that positrons and positronium (Ps) atoms mainly annihilate from trapped states by vacancy-type defects in v-SiO 2 . For v-SiO 2 specimens with cylindrical porous structures, annihilations of Ps with anisotropic momentum distributions were observed. This fact was attributed to the momentum uncertainty due to localization of Ps in a finite dimension of pores. This investigation showed possibilities for the detection of microstructures in v-SiO 2 by the positron annihilation technique. (author)

  15. Positrons in ionic crystals

    International Nuclear Information System (INIS)

    Pareja, R.

    1988-01-01

    Positron annihilation experiments in ionic crystals are reviewed and their results are arranged. A discussion about the positron states in these materials is made in the light of these results and the different proposed models. The positronium in alkali halides is specially considered. (Author)

  16. Positron annihilation in SiO 2-Si studied by a pulsed slow positron beam

    Science.gov (United States)

    Suzuki, R.; Ohdaira, T.; Uedono, A.; Kobayashi, Y.

    2002-06-01

    Positron and positronium (Ps) behavior in SiO 2-Si have been studied by means of positron annihilation lifetime spectroscopy (PALS) and age-momentum correlation (AMOC) spectroscopy with a pulsed slow positron beam. The PALS study of SiO 2-Si samples, which were prepared by a dry-oxygen thermal process, revealed that the positrons implanted in the Si substrate and diffused back to the interface do not contribute to the ortho-Ps long-lived component, and the lifetime spectrum of the interface has at least two components. From the AMOC study, the momentum distribution of the ortho-Ps pick-off annihilation in SiO 2, which shows broader momentum distribution than that of crystalline Si, was found to be almost the same as that of free positron annihilation in SiO 2. A varied interface model was proposed to interpret the results of the metal-oxide-semiconductor (MOS) experiments. The narrow momentum distribution found in the n-type MOS with a negative gate bias voltage could be attributed to Ps formation and rapid spin exchange in the SiO 2-Si interface. We have developed a two-dimensional positron lifetime technique, which measures annihilation time and pulse height of the scintillation gamma-ray detector for each event. Using this technique, the positronium behavior in a porous SiO 2 film, grown by a sputtering method, has been studied.

  17. Theoretical calculations of positron lifetimes for metal oxides

    International Nuclear Information System (INIS)

    Mizuno, Masataka; Araki, Hideki; Shirai, Yasuharu

    2004-01-01

    Our recent positron lifetime measurements for metal oxides suggest that positron lifetimes of bulk state in metal oxides are shorter than previously reported values. We have performed theoretical calculations of positron lifetimes for bulk and vacancy states in MgO and ZnO using first-principles electronic structure calculations and discuss the validity of positron lifetime calculations for insulators. By comparing the calculated positron lifetimes to the experimental values, it wa found that the semiconductor model well reproduces the experimental positron lifetime. The longer positron lifetime previously reported can be considered to arise from not only the bulk but also from the vacancy induced by impurities. In the case of cation vacancy, the calculated positron lifetime based on semiconductor model is shorter than the experimental value, which suggests that the inward relaxation occurs around the cation vacancy trapping the positron. (author)

  18. Production and applications of positron microbeams

    International Nuclear Information System (INIS)

    Brandes, G.R.; Canter, K.F.; Horsky, T.N.; Lippel, P.H.; Mills, A.P. Jr.

    1989-01-01

    The production of a positron microbeam using the high-brightness beam developed at Brandeis University and possible applications of this microbeam to spatially resolved defect studies and positron microscopy are reviewed. The high-brightness beam consists of a W(110) primary moderator and two remoderation stages which provide a 500-fold increase in brightness. With this brightness increase and microbeam optics, we are able to form a 12 μm FWHM beam (48 mrad pencil half-angle) at 5 keV beam energy. The well characterised small-diameter beam is particularly adaptable for determining defect concentration and structure, both laterally and in a depth-profiling mode. In the case of a transmission positron microscope or a positron re-emission microscope operating in a high-magnification mode, efficient image formation requires the use of a microbeam to maximise the number of positrons in the area being imaged. Results of the scanning microbeam tests and the application of a microbeam to positron microscopy and defect studies are reviewed. (author)

  19. Low energy scattering of positrons by H{sub 2}O

    Energy Technology Data Exchange (ETDEWEB)

    Arretche, F., E-mail: fsc1sem@fsc.ufsc.b [Departamento de Fisica, Universidade do Estado de Santa Catarina, 89223-100, Joinville, Santa Catarina (Brazil); Tenfen, W.; Mazon, K.T.; Michelin, S.E. [Departamento de Fisica, Universidade Federal de Santa Catarina, 88040-900, Florianopolis, Santa Catarina (Brazil); Lima, M.A.P. [Instituto de Fisica Gleb Wataghin, Universidade Estadual de Campinas, Unicamp, 13083-970, Campinas, Sao Paulo (Brazil); Lee, M.-T. [Departamento de Quimica, Universidade Federal de Sao Carlos, 13565-905, Sao Carlos, Sao Paulo (Brazil); Machado, L.E. [Departamento de Fisica, Universidade Federal de Sao Carlos, 13565-905, Sao Carlos, Sao Paulo (Brazil); Fujimoto, M.M. [Departamento de Fisica, Universidade Federal do Parana, 13565-905, Curitiba, Parana (Brazil); Pessoa, O.A. [Departamento de Fisica, Universidade do Estado de Santa Catarina, 89111-100, Sao Bento do Sul, Santa Catarina (Brazil)

    2010-01-15

    We present a theoretical investigation on elastic positron-H{sub 2}O collisions. More specifically, differential and integral cross sections in the 0-10 eV energy range are reported. The calculations were performed using two theoretical approaches, namely, the Schwinger multichannel method and the method of continued fractions. The positron-molecule interaction dynamics is described by using a potential composed of static and correlation-polarization contributions. Comparison of our calculated results with the recent experimental of Zecca et al. [J. Phys. B 39 (2006) 1597] and theoretical results is encouraging.

  20. Optical model theory of elastic electron- and positron-atom scattering at intermediate energies

    International Nuclear Information System (INIS)

    Joachain, C.J.

    1977-01-01

    It is stated that the basic idea of the optical model theory is to enable analysis of the elastic scattering of a particle from a complex target by replacing the complicated interactions between the beam and the target by an optical potential, or pseudopotential, in which the incident particle moves. Once the optical potential is determined the original many-body elastic scattering problem reduces to a one-body situation. The resulting optical potential is, however, a very complicated operator, and the formal expressions obtained from first principles for the optical potential can only be evaluated approximately in a few simple cases, such as high energy elastic hadron-nucleus scattering, for the the optical potential can be expressed in terms of two-body hadron-nucleon amplitudes, and the non-relativistic elastic scattering of fast charged particles by atoms. The elastic scattering of an electron or positron by a neutral atom at intermediate energies is here considered. Exchange effects between the projectile and the atomic electrons are considered; also absorption and polarisation effects. Applications of the full-wave optical model have so far only been made to the elastic scattering of fast electrons and positrons by atomic H, He, Ne, and Ar. Agreements of the optical model results with absolute measurements of differential cross sections for electron scattering are very good, an agreement that improves as the energy increases, but deteriorates quickly as the incident energy becomes lower than 50 eV for atomic H or 100 eV for He. For more complex atoms the optical model calculations also appear very encouraging. With regard to positron-atom elastic scattering the optical model results for positron-He scattering differ markedly at small angles from the corresponding electron-He values. It would be interesting to have experimental angular distributions of positron-atom elastic scattering in order to check predictions of the optical model theory. (U.K.)

  1. Time-dependent behavior of positrons in noble gases

    International Nuclear Information System (INIS)

    Wadehra, J.M.

    1990-01-01

    Both equilibrium and nonequilibrium behaviors of positrons in several noble gases are reviewed. Our novel procedure for obtaining the time-dependent behavior of various swarm parameters -- such as the positron drift velocity, average positron energy, positron annihilation rate (or equivalently Z eff ) etc. -- for positrons in pure ambient gases subjected to external electrostatic fields is described. Summaries of time-dependent as well as electric field-dependent results for positron swarms in various noble gases are presented. New time-dependent results for positron swarms in neon are also described in detail. 36 refs., 4 figs., 3 tabs

  2. Solvated Positron Chemistry. II

    DEFF Research Database (Denmark)

    Mogensen, O. E.

    1979-01-01

    The reaction of the hydrated positron, eaq+ with Cl−, Br−, and I− ions in aqueous solutions was studied by means of positron The measured angular correlation curves for [Cl−, e+], [Br−, e+, and [I−, e+] bound states were in good agreement with th Because of this agreement and the fact...... that the calculated positron wavefunctions penetrate far outside the X− ions in the [X−, e+] sta propose that a bubble is formed around the [X−, e+] state, similar to the Ps bubble found in nearly all liquids. F−ions did not react w Preliminary results showed that CN− ions react with eaq+ while OH−ions are non...... in the Cl− case) at higher concentrations. This saturation and the high-concentration effects-in the angular correlation results were interpreted as caused by rather complicated spur effects, wh It is proposed that spur electrons may pick off the positron from the [X−, e+ states with an efficiency which...

  3. Radiation damage of polymers studied by positron annihilation. Positron and gamma-ray irradiation effects

    International Nuclear Information System (INIS)

    Suzuki, T.; Oki, Y.; Numajiri, M.; Miura, T.; Kondo, K.; Ito, Y.

    1995-01-01

    Positron irradiation effects on polypropylene (PP) have been studied using positron sources ( 22 Na) during positron annihilation (PA) experiments. The irradiation effect was measured by the intensity (I 3 ) of the long-lived component of positronium (Ps). At a low temperature of around 100 K, I 3 for unirradiated PP samples increased due to a termination of the thermal motion of the -CH 3 groups. However, the increase in I 3 for γ-ray irradiated samples was reduced in inverse proportion to the amount of irradiation. Although no increase in I 3 was observed for 1 MGy-irradiated PP with γ-rays, an increase was observed again after a 48 h irradiation by positrons emitted from 22 Na. This may be due to a reconstructing of the polymer chains. (author)

  4. Effects of positron density and temperature on large amplitude ion-acoustic waves in an electron-positron-ion plasma

    International Nuclear Information System (INIS)

    Nejoh, Y.N.

    1997-01-01

    The nonlinear wave structures of large amplitude ion-acoustic waves are studied in a plasma with positrons. We have presented the region of existence of the ion-acoustic waves by analysing the structure of the pseudopotential. The region of existence sensitively depends on the positron to electron density ratio, the ion to electron mass ratio and the positron to electron temperature ratio. It is shown that the maximum Mach number increases as the positron temperature increases and the region of existence of the ion-acoustic waves spreads as the positron temperature increases. 12 refs., 6 figs

  5. Importance of non-local electron-positron correlations for positron annihilation characteristics in solids

    International Nuclear Information System (INIS)

    Rubaszek, A.

    2001-01-01

    Several methods to describe the electron-positron (e-p) correlation effects are used in calculations of positron annihilation characteristics in solids. The weighted density approximation (WDA), giving rise to the non-local, state-selective e-p correlation functions, is applied to calculate positron annihilation rates and e-p momentum densities in a variety of metals and silicon. The WDA results are compared to the results of other methods such as the independent particle model, local density approximation, generalised gradient approximation, and also to experiments. The importance of non-locality and state-dependence of the e-p correlation functions is discussed. (orig.)

  6. Positron source based on the 48V isotope dedicated to positron lifetime spectroscopy

    International Nuclear Information System (INIS)

    Dryzek, Jerzy

    2009-01-01

    In the paper we consider application of the 48 V isotope as a source in the positron lifetime spectroscopy. The isotope was produced in the 48 Ti(p,n) 48 V reaction using 15 MeV proton beam. As a target the natural titanium thin plate was used. The measurements using the typical positron lifetime spectrometer have shown the usefulness of the source obtained for this application. Due to its properties, the source may be used for measurements of positron annihilation characteristics in high temperature or aggressive environments. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  7. Applications of positron depth profiling

    Energy Technology Data Exchange (ETDEWEB)

    Hakvoort, R A

    1993-12-23

    In this thesis some contributions of the positron-depth profiling technique to materials science have been described. Following studies are carried out: Positron-annihilation measurements on neon-implanted steel; Void creation in silicon by helium implantation; Density of vacancy-type defects present in amorphous silicon prepared by ion implantation; Measurements of other types of amorphous silicon; Epitaxial cobalt disilicide prepared by cobalt outdiffusion. Positron-annihilation experiments on low-pressure CVD silicon-nitride films. (orig./MM).

  8. Applications of positron depth profiling

    International Nuclear Information System (INIS)

    Hakvoort, R.A.

    1993-01-01

    In this thesis some contributions of the positron-depth profiling technique to materials science have been described. Following studies are carried out: Positron-annihilation measurements on neon-implanted steel; Void creation in silicon by helium implantation; Density of vacancy-type defects present in amorphous silicon prepared by ion implantation; Measurements of other types of amorphous silicon; Epitaxial cobalt disilicide prepared by cobalt outdiffusion. Positron-annihilation experiments on low-pressure CVD silicon-nitride films. (orig./MM)

  9. Clinical cardiac positron emission tomography: State of the art

    International Nuclear Information System (INIS)

    Gould, K.L.

    1991-01-01

    Cardiac positron emission tomography (PET) has evolved rapidly from a relatively esoteric research tool into clinical applications providing unique, quantitative information on myocardial perfusion, metabolism, and cell membrane function and having a potentially significant impact on cardiovascular medicine. Although there are many different positron radionuclides for imaging diverse myocardial behavior, three radionuclides have reached accepted clinical utility. Cardiac PET using nitrogen-13-ammonia, rubidium-82, and fluoro-18-deoxyglucose has proved accurate and definitive in multiple university and private-practice sites for diagnosing and assessing severity and location of coronary artery disease in symptomatic or asymptomatic patients, for identifying injured but viable myocardium potentially salvageable by revascularization, and for ruling out clinically significant coronary artery stenosis with a high specificity in patients who might otherwise undergo coronary arteriography to document the absence of significant disease. 89 references

  10. The non-destructive examination of reactor pressure vessel steels by positron annihilation

    International Nuclear Information System (INIS)

    Highton, J.P.

    1983-01-01

    The rapid radiation hardening of copper bearing reactor pressure vessel steels has been linked with microvoids that are associated with copper based complexes in the metal lattice. These microvoids are active in the sense that their size appears to be related to the temperature of irradiation, which thus determines their influence on dislocation mobility. These sites appear to grow by vacancy condensation which causes a reduction in the local lattice energy. Thus prolonged exposure to PWR temperatures, even in the absence of a neutron flux, may also cause embrittlement. It has been found that these sites, which represent a local negative charge, act as traps to positrons. The size of each site dictates its positron trapping potential. As the trapping potential increases so too does the probability that the positrons will annihilate with low momentum conduction electrons. The momentum of the annihilating electrons will determine the degree of Doppler broadening of the 511 keV annihilation gamma peak. Thus careful analysis of this peak can yield useful information on the degree of embrittlement caused by these active defect complexes. In this way positron annihilation offers a powerful non-destructive alternative to current methods of assessing the integrity of nuclear reactor pressure vessels. (author)

  11. Positron emission tomography

    International Nuclear Information System (INIS)

    Lindback, Stig

    1995-01-01

    Positron Emission Tomography (PET) is an advanced nuclear medicine technique used for research at major centres. Unique diagnostic information is obtained from tomographic measurements of the biochemistry and physiology of tissues and organs. In theory, diseases are related to biochemical changes and these can be observed with PET long before any anatomical changes are detectable. In PET the radioactive component is a positron-emitting isotope or 'tracer'. The positrons annihilate with electrons in the body to produce two gamma rays 180° apart; coincidence detection of these gammas provides a very efficient method of determining the spatial distribution of the radioisotope tracer. Because physiological measurements are usually required in a single imaging session, very short-lived isotopes are used to label the tracer molecules; isotope production and labelling is usually carried out in situ. The most commonly used radionuclides are carbon- 11 (half-life 20 minutes), nitrogen-13 (10 minutes), oxygen-15 (2 minutes), and fluorine-18 (110 minutes). A PET system has three major components: - a particle accelerator with targets for production of the positron-emitting isotopes; - chemistry modules for synthesis and labelling of the desired tracers; - and a PET camera for in-vivo measurements of the distribution of the tracer in the body

  12. Positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lindback, Stig [GEMS PET Systems AB, Uppsala (Sweden)

    1995-07-15

    Positron Emission Tomography (PET) is an advanced nuclear medicine technique used for research at major centres. Unique diagnostic information is obtained from tomographic measurements of the biochemistry and physiology of tissues and organs. In theory, diseases are related to biochemical changes and these can be observed with PET long before any anatomical changes are detectable. In PET the radioactive component is a positron-emitting isotope or 'tracer'. The positrons annihilate with electrons in the body to produce two gamma rays 180° apart; coincidence detection of these gammas provides a very efficient method of determining the spatial distribution of the radioisotope tracer. Because physiological measurements are usually required in a single imaging session, very short-lived isotopes are used to label the tracer molecules; isotope production and labelling is usually carried out in situ. The most commonly used radionuclides are carbon- 11 (half-life 20 minutes), nitrogen-13 (10 minutes), oxygen-15 (2 minutes), and fluorine-18 (110 minutes). A PET system has three major components: - a particle accelerator with targets for production of the positron-emitting isotopes; - chemistry modules for synthesis and labelling of the desired tracers; - and a PET camera for in-vivo measurements of the distribution of the tracer in the body.

  13. Positron probes of the Ge(1 0 0) surface: The effects of surface reconstructions and electron-positron correlations on positron trapping and annihilation characteristics

    International Nuclear Information System (INIS)

    Fazleev, N.G.; Jung, E.; Weiss, A.H.

    2007-01-01

    Positron annihilation induced Auger electron spectroscopy (PAES) has been applied to study the Ge(1 0 0) surface. The high-resolution PAES spectrum from the Ge(1 0 0) surface displays several strong Auger peaks corresponding to M 4,5 N 1 N 2,3 , M 2,3 M 4,5 M 4,5 , M 2,3 M 4,5 V and M 1 M 4,5 M 4,5 Auger transitions. The integrated peak intensities of Auger transitions are used to obtain experimental annihilation probabilities for the Ge 3d and 3p core level electrons. These experimental results are analyzed by performing calculations of positron surface states and annihilation characteristics of surface trapped positrons with relevant Ge core-level electrons for the non-reconstructed and reconstructed Ge(1 0 0)-p(2 x 1), Ge(1 0 0)-p(2 x 2) and Ge(1 0 0)-c(4 x 2) surfaces. It is found that the positron surface state wave function extends into the Ge lattice in the regions where atoms are displaced from their ideal terminated positions due to reconstructions. Estimates of the positron binding energy and the positron annihilation characteristics reveal their sensitivity to the specific atomic structure of the topmost layers of Ge(1 0 0). A comparison with PAES data reveals an agreement with theoretical core annihilation probabilities for the Auger transitions considered

  14. Use of positron annihilation spectroscopy for the study and characterization of materials

    International Nuclear Information System (INIS)

    Somoza, Alberto

    1998-01-01

    In this work the potentiality of positron annihilation spectroscopy (PAS) for the study and characterization of materials is presented, the physical principles of the electron-positron annihilation process is described, as well as the experimental techniques to measure such process. The greatest application fields of positron techniques are the study of electronic structures and defects in condensed matter. The quality of the information obtained suggests that PAS techniques could turn into an alternative of great importance to undertake the study of different material properties. During the development of this work, special emphasis was put on PAS application to the study of defects in metals and alloys, where it was shown the great sensibility of positrons to vacancies type-defects covering the range between mono vacancies and clusters that contain between 50 and 100 vacancies, for a concentration range between 10 -4 and 10 -7 at. -1 . Such range is below the sizes that can be visualized through electron microscopy. This high sensibility is, in turn, one of PAS limitations for the study of greater size defects. Also the positrons are insensible to defects such as interstitials, which present an electron density greater than the average. The development of slow positron beams that enable the study of spatial distribution of defects has permitted to complement PAS conventional techniques. In this way the joint use of the different positron techniques provides complete information about the nature, concentration and distribution of defects in solids

  15. The cryogenic source of slow monochromatic positrons

    International Nuclear Information System (INIS)

    Meshkov, I.N.; Pavlov, V.N.; Sidorin, A.O.; Yakovenko, S.L.

    2008-01-01

    The cryogenic source of slow monochromatic positrons based on the 22 Na isotope has been designed and constructed at JINR. Positrons emitted from radioactive source 22 Na have a very broad energy spectrum up to 0.5 MeV. To generate monochromatic beam of slow positrons the solid neon is used as a moderator. The solid neon allows forming slow positron beam of the energy of 1.2 eV at the spectrum width of 1 eV. The efficiency of moderation is 1 % of total positron flux

  16. Probing the positron moderation process using high-intensity, highly polarized slow-positron beams

    Science.gov (United States)

    Van House, J.; Zitzewitz, P. W.

    1984-01-01

    A highly polarized (P = 0.48 + or - 0.02) intense (500,000/sec) beam of 'slow' (Delta E = about 2 eV) positrons (e+) is generated, and it is shown that it is possible to achieve polarization as high as P = 0.69 + or - 0.04 with reduced intensity. The measured polarization of the slow e+ emitted by five different positron moderators showed no dependence on the moderator atomic number (Z). It is concluded that only source positrons with final kinetic energy below 17 keV contribute to the slow-e+ beam, in disagreement with recent yield functions derived from low-energy measurements. Measurements of polarization and yield with absorbers of different Z between the source and moderator show the effects of the energy and angular distributions of the source positrons on P. The depolarization of fast e+ transmitted through high-Z absorbers has been measured. Applications of polarized slow-e+ beams are discussed.

  17. High efficiency positron moderation

    International Nuclear Information System (INIS)

    Taqqu, D.

    1990-01-01

    A new positron moderation scheme is proposed. It makes use of electric and magnetic fields to confine the β + emitted by a radioactive source forcing them to slow down within a thin foil. A specific arrangement is described where an intermediary slowed-down beam of energy below 10 keV is produced. By directing it towards a standard moderator optimal conversion into slow positrons is achieved. This scheme is best applied to short lived β + emitters for which a 25% moderation efficiency can be reached. Within the state of the art technology a slow positron source intensity exceeding 2 x 10 10 e + /sec is achievable. (orig.)

  18. Positron emission tomography

    International Nuclear Information System (INIS)

    Chandrasekhar, Preethi; Himabindu, Pucha

    2000-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging technique used to study different molecular pathways and anatomical structures. PET has found extensive applications in various fields of medicine viz. cardiology, oncology, psychiatry/psychology, neuro science and pulmonology. This study paper basically deals with the physics, chemistry and biology behind the PET technique. It discusses the methodology for generation of the radiotracers responsible for emission of positrons and the annihilation and detection techniques. (author)

  19. Positron emission tomography

    International Nuclear Information System (INIS)

    Dvorak, O.

    1989-01-01

    The principle is briefly described of positron emission tomography, and its benefits and constraints are listed. It is emphasized that positron emission tomography (PET) provides valuable information on metabolic changes in the organism that are otherwise only very difficult to obtain, such as brain diagnosis including relationships between mental disorders and the physiology and pathophysiology of the brain. A PET machine is to be installed in Czechoslovakia in the near future. (L.O.)

  20. Relevance of slow positron beam research to astrophysical studies of positron interactions and annihilation in the interstellar medium

    International Nuclear Information System (INIS)

    Guessoum, N.; Jean, P.; Gillard, W.

    2006-01-01

    The processes undergone by positrons in the interstellar medium (ISM) from the moments of their birth to their annihilation are examined. Both the physics of the positron interactions with gases and solids (dust grains), and the physical conditions and characteristics of the environments where the processes of energy loss, positronium formation, and annihilation taking place, are reviewed. An explanation is given as to how all the relevant physical information are taken into account in order to calculate annihilation rates and spectra of the 511 keV emission for the various phases of the ISM; special attention is paid to positron interactions with dust and with polycyclic aromatic hydrocarbons. An attempt is made to show to what extent the interactions between positrons and interstellar dust grains are similar to laboratory experiments in which beams of slow positrons impinge upon solids and surfaces. Sample results are shown for the effect of dust grains on positron annihilation spectra in some phases of the ISM which, together with high resolution spectra measured by satellites, can be used to infer useful knowledge about the environment where the annihilation is predominantly taking place and ultimately about the birth place and history of positrons in the Galaxy. The important complementarity between work done by the astrophysical and the solid-state positron communities is strongly emphasized and specific experimental work is suggested which could assist the modeling of the interaction and annihilation of positrons in the ISM

  1. Relevance of slow positron beam research to astrophysical studies of positron interactions and annihilation in the interstellar medium

    Energy Technology Data Exchange (ETDEWEB)

    Guessoum, N. [American University of Sharjah, Physics Department, P.O. Box 26666, Sharjah (United Arab Emirates)]. E-mail: nguessoum@aus.ac.ae; Jean, P. [Centre d' Etude Spatiale des Rayonnements, Toulouse (France); Gillard, W. [Centre d' Etude Spatiale des Rayonnements, Toulouse (France)

    2006-02-28

    The processes undergone by positrons in the interstellar medium (ISM) from the moments of their birth to their annihilation are examined. Both the physics of the positron interactions with gases and solids (dust grains), and the physical conditions and characteristics of the environments where the processes of energy loss, positronium formation, and annihilation taking place, are reviewed. An explanation is given as to how all the relevant physical information are taken into account in order to calculate annihilation rates and spectra of the 511 keV emission for the various phases of the ISM; special attention is paid to positron interactions with dust and with polycyclic aromatic hydrocarbons. An attempt is made to show to what extent the interactions between positrons and interstellar dust grains are similar to laboratory experiments in which beams of slow positrons impinge upon solids and surfaces. Sample results are shown for the effect of dust grains on positron annihilation spectra in some phases of the ISM which, together with high resolution spectra measured by satellites, can be used to infer useful knowledge about the environment where the annihilation is predominantly taking place and ultimately about the birth place and history of positrons in the Galaxy. The important complementarity between work done by the astrophysical and the solid-state positron communities is strongly emphasized and specific experimental work is suggested which could assist the modeling of the interaction and annihilation of positrons in the ISM.

  2. Neurotoxic Alkaloids: Saxitoxin and Its Analogs

    Directory of Open Access Journals (Sweden)

    Troco K. Mihali

    2010-07-01

    Full Text Available Saxitoxin (STX and its 57 analogs are a broad group of natural neurotoxic alkaloids, commonly known as the paralytic shellfish toxins (PSTs. PSTs are the causative agents of paralytic shellfish poisoning (PSP and are mostly associated with marine dinoflagellates (eukaryotes and freshwater cyanobacteria (prokaryotes, which form extensive blooms around the world. PST producing dinoflagellates belong to the genera Alexandrium, Gymnodinium and Pyrodinium whilst production has been identified in several cyanobacterial genera including Anabaena, Cylindrospermopsis, Aphanizomenon Planktothrix and Lyngbya. STX and its analogs can be structurally classified into several classes such as non-sulfated, mono-sulfated, di-sulfated, decarbamoylated and the recently discovered hydrophobic analogs—each with varying levels of toxicity. Biotransformation of the PSTs into other PST analogs has been identified within marine invertebrates, humans and bacteria. An improved understanding of PST transformation into less toxic analogs and degradation, both chemically or enzymatically, will be important for the development of methods for the detoxification of contaminated water supplies and of shellfish destined for consumption. Some PSTs also have demonstrated pharmaceutical potential as a long-term anesthetic in the treatment of anal fissures and for chronic tension-type headache. The recent elucidation of the saxitoxin biosynthetic gene cluster in cyanobacteria and the identification of new PST analogs will present opportunities to further explore the pharmaceutical potential of these intriguing alkaloids.

  3. Positron emission tomography in brain function study

    International Nuclear Information System (INIS)

    Wu Hua

    2006-01-01

    Little has been recognized about the advanced brain function. Recent years several new techniques such as event-related potentials, megnetoencephalography, functional magnetic resonance imaging and positron emission tomography (PET) have been used in the study of brain function. The methodology, application study in normal people and clinical patients of PET in brain function are reviewed. (authors)

  4. Three dimensional positron-CT: 3D-PET

    International Nuclear Information System (INIS)

    Ishii, K.

    2000-01-01

    Positron-CT, namely the positron emission tomograph (PET) provides us the metabolism images obtained by the administration of the drug labeled by the positron emission nuclide in the human body. For example, the carbohydrate metabolism image is obtained by the administration of glucose labelled by 18 F-radioisotopes, and it can be applied to early detection of the cancer and research of high-order function of the brain. As well as X-ray CT, the examine receives the exposure in the positron CT. 3D-PET is based on the solid measurement of γ-rays, therefore, the detection sensitivity of 3D-PET becomes very high and it is possible to drastically reduce the dose of the positron emission nuclide. Because the exposure is reduced to the utmost, the positron CT diagnosis would be possible for the child and the exposure of positron CT doctor in charge can be also reduced. This ideal functional diagnostic imaging equipment, namely, 3D-PET is introduced here. (author)

  5. Theoretical calculations of positron annihilation characteristics in inorganic solids -- Recent advances and problems

    Science.gov (United States)

    Sob, M.; Sormann, H.; Kuriplach, J.

    Principles and applications of positron annihilation spectroscopy to electronic structure and defect studies are briefly reviewed and some recent advances and pending problems are illustrated by specific examples. In particular, it turns out that the sensitivity of calculated momentum densities of electron-positron annihilation pairs (MDAP) to the choice of electron crystal potential is higher or comparable to its sensitivity with respect to the choice of description of the electron-positron interaction. As a result, it is very hard to distinguish between various electron-positron interaction theories on the basis of the comparison of theoretical and experimental MDAPs. Furthermore, the positron affinity is determined theorttically for several systems having a band gap (semiconductors, insulators). It appears that the calculated positron affinities are significantly underestimated when compared to experimental data and, apparently, electron-positron interactions in such systems are not described satisfactorily by contemporary theoretical approaches. The above examples are related rather to electronic structure studies, but positrons are often used to investigate various open-volume defects in solids, which is dealt with in the last illustration. A non-selfconsistent computational technique suitable for the theoretical examination of configurations having large number (thousands) of non-equivalent atoms has been updated recently to treat non-periodic solids. It is based on the superposition of atomic densities in order to approximate the electronic density of the system studied. Though the charge redistribution due to selfconsistency effects is neglected, positron annihilation characteristics are determined quite reasonably. This allows for studying properties of extended defects like grain boundaries (and other interfaces), dislocations, precipitates, etc., which is very helpful when interpreting experimental positron annihilation data. Our technique is

  6. Conceptual design of a high-intensity positron source for the Advanced Neutron Source

    International Nuclear Information System (INIS)

    Hulett, L.D.; Eberle, C.C.

    1994-12-01

    The Advanced Neutron Source (ANS) is a planned new basic and applied research facility based on a powerful steady-state research reactor that provides neutrons for measurements and experiments in the fields of materials science and engineering, biology, chemistry, materials analysis, and nuclear science. The useful neutron flux will be at least five times more than is available in the world's best existing reactor facility. Construction of the ANS provides a unique opportunity to build a positron spectroscopy facility (PSF) with very-high-intensity beams based on the radioactive decay of a positron-generating isotope. The estimated maximum beam current is 1000 to 5000 times higher than that available at the world's best existing positron research facility. Such an improvement in beam capability, coupled with complementary detectors, will reduce experiment durations from months to less than one hour while simultaneously improving output resolution. This facility will remove the existing barriers to the routine use of positron-based analytical techniques and will be a giant step toward realization of the full potential of the application of positron spectroscopy to materials science. The ANS PSF is based on a batch cycle process using 64 Cu isotope as the positron emitter and represents the status of the design at the end of last year. Recent work not included in this report, has led to a proposal for placing the laboratory space for the positron experiments outside the ANS containment; however, the design of the positron source is not changed by that relocation. Hydraulic and pneumatic flight tubes transport the source material between the reactor and the positron source where the beam is generated and conditioned. The beam is then transported through a beam pipe to one of several available detectors. The design presented here includes all systems necessary to support the positron source, but the beam pipe and detectors have not been addressed yet

  7. 64Cu-DOTA as a surrogate positron analog of Gd-DOTA for cardiac fibrosis detection with PET: pharmacokinetic study in a rat model of chronic MI.

    Science.gov (United States)

    Kim, Heejung; Lee, Sung-Jin; Davies-Venn, Cynthia; Kim, Jin Su; Yang, Bo Yeun; Yao, Zhengsheng; Kim, Insook; Paik, Chang H; Bluemke, David A

    2016-02-01

    The aim of this study was to investigate the pharmacokinetics of (64)Cu-DOTA (1,4,7,10-azacyclododecane-N,N',N'',N'''-tetraacetic acid), a positron surrogate analog of the late gadolinium (Gd)-enhancement cardiac magnetic resonance agent, Gd-DOTA, in a rat model of chronic myocardial infarction (MI) and its microdistribution in the cardiac fibrosis by autoradiography. DOTA was labeled with (64)Cu-acetate. CD rats (n=5) with MI by left anterior descending coronary artery ligation and normal rats (n=6) were injected intravenously with (64)Cu-DOTA (18.5 MBq, 0.02 mmol DOTA/kg). Dynamic PET imaging was performed for 60 min after injection. (18)F-Fluorodeoxyglucose ([(18)F]-FDG) PET imaging was performed to identify the viable myocardium. For the region of interest analysis, the (64)Cu-DOTA PET image was coregistered to the [(18)F]-FDG PET image. To validate the PET images, slices of heart samples from the base to the apex were analyzed using autoradiography and by histological staining with Masson's trichrome. (64)Cu-DOTA was rapidly taken up in the infarct area. The time-activity curves demonstrated that (64)Cu-DOTA concentrations in the blood, fibrotic tissue, and perfusion-rich organs peaked within a minute post injection; thereafter, it was rapidly washed out in parallel with blood clearance and excreted through the renal system. The blood clearance curve was biphasic, with a distribution half-life of less than 3 min and an elimination half-life of ∼21.8 min. The elimination half-life of (64)Cu-DOTA from the focal fibrotic tissue (∼22.4 min) and the remote myocardium (∼20.1 min) was similar to the blood elimination half-life. Consequently, the uptake ratios of focal fibrosis-to-blood and remote myocardium-to-blood remained stable for the time period between 10 and 60 min. The corresponding ratios obtained from images acquired from 30 to 60 min were 1.09 and 0.59, respectively, indicating that the concentration of (64)Cu-DOTA in the focal

  8. Positron lifetime technique with applications in materials science

    International Nuclear Information System (INIS)

    Vries, J. de.

    1987-01-01

    This thesis deals with the positron lifetime technique as a method to measure extremely low concentrations of extremely small cavities in materials. The method is based upon the fact that the positron lieftime decreases as the electron density increases and upon the fact that a positron preferably annihilates in cavity-like defects in lattices. The theory of positron behaviour in materials and technical aspects of measuring positron liefetimes are described in ch.'s 2 and 3 respectively. Three methods for increasing the time resolution are discussed and some positron sources are described (ch.4). Some applications of the positron lifetime technique and experimental results are shown in chapter 5. 125 refs.; 61 figs.; 18 tabs

  9. Results on positron diffusion in Si

    International Nuclear Information System (INIS)

    Nielsen, B.; Lynn, K.G.; Vehanen, A.; Schultz, P.J.

    1984-10-01

    Positron diffusion in Si(100) and Si(111) has been measured using a variable energy positron beam. The diffusion related parameter, E 0 is found to be 4.2 +- 0.2 keV, significantly longer than previously reported values. The positron diffusion coefficient is estimated at D/sub +/ = 2.3 +- 0.4 cm 2 /sec, the uncertainty arising mainly from the characteristics of the assumed positron implantation profile. A drastic reduction in E 0 is found after heating the sample to 1300 0 K, showing that previously reported low values of E 0 are associated with the thermal history of the sample. A high sensitivity to defects introduced by low energy ion bombardment is found, and the defect recovery was followed during heat treatments. Reconstruction of the Si(111) surface into the so-called 7 x 7 structure had no detectable influence on the positron diffusion behavior. No changes in the positron diffusion was observed after covering the surface with atomic hydrogen. However the yield of positronium formation at the surface was enhanced, attributed to an increased density of states at the surface

  10. Positrons from supernova and the origin of the galactic-center positron-annihilation radiation

    International Nuclear Information System (INIS)

    Colgate, S.A.

    1983-01-01

    The emission of positrons from supernova ejecta is dicussed in terms of the galactic-center annihilation radiation. The positrons from the radioactive sequences 56 Ni→ 56 Co→ 56 Fe are the most numerous source from supernova. Only type I supernova will allow a significant fraction to escape the expanding ejecta. For a neutron star model of a type I SN a fraction 4 x 10 -3 of the escaped positron is enough to create the observed several year fluctuation of the annihilation radiation. The likelihood of this model is discussed in terms of other astrophysical evidence as well as the type I SN light curve

  11. Theoretical aspects of positrons in imperfect solids

    International Nuclear Information System (INIS)

    Puska, M.J.

    1987-01-01

    The efficient use of positron annihilation in defect studies requires a deep understanding of the basic processes of positron-imperfect solid interaction. Three stages, i.e. thermalization, trapping by a defect, and the annihilation can be separated during the evolution of the interaction. The last two processes are the most relevant ones for the positron lifetime spectroscopy and they will be discussed in detail in this review. The complete solution of the problem of a localized positron interacting with the electrons around a defect requires the simultaneous self-consistent calculation of the electronic structure and the positron state. This is in principle possible in the two component density functional theory. However, the approximation, in which the electronic structure without the positron influence is used and the electron-positron correlation effects are described by local enhancement factors, has turned out to be feasible in practice and also accurate enough in predicting positron annihilation characteristics. Moreover, a non-self-consistent electron structure is sufficient in many cases. This enables an efficient calculation method in which the positron wave function can be solved in three dimensions for arbitrary defect geometries. Enhancement models for simple metals, transition metals, and semiconductors are represented. Thereafter, applications to vacancies, vacancy clusters, and vacancy-impurity complexes are shown. The positron trapping by defects is mediated by the transfer of the positron binding energy to the solid in the form of electron-hole pairs and phonons. The trapping phenomenon is discussed in the case of metals and semiconductors. Semiconductors are especially challenging because the existence of the energy gap makes the low energy electron-hole excitations impossible and because the defects have different charge states effecting strongly on the trapping rate. (author)

  12. Pulsars as the sources of high energy cosmic ray positrons

    International Nuclear Information System (INIS)

    Hooper, Dan; Blasi, Pasquale; Serpico, Pasquale Dario

    2009-01-01

    Recent results from the PAMELA satellite indicate the presence of a large flux of positrons (relative to electrons) in the cosmic ray spectrum between approximately 10 and 100 GeV. As annihilating dark matter particles in many models are predicted to contribute to the cosmic ray positron spectrum in this energy range, a great deal of interest has resulted from this observation. Here, we consider pulsars (rapidly spinning, magnetized neutron stars) as an alternative source of this signal. After calculating the contribution to the cosmic ray positron and electron spectra from pulsars, we find that the spectrum observed by PAMELA could plausibly originate from such sources. In particular, a significant contribution is expected from the sum of all mature pulsars throughout the Milky Way, as well as from the most nearby mature pulsars (such as Geminga and B0656+14). The signal from nearby pulsars is expected to generate a small but significant dipole anisotropy in the cosmic ray electron spectrum, potentially providing a method by which the Fermi gamma-ray space telescope would be capable of discriminating between the pulsar and dark matter origins of the observed high energy positrons

  13. Monte Carlo transport of electrons and positrons through thin foils

    International Nuclear Information System (INIS)

    Legarda, F.; Idoeta, R.

    2000-01-01

    In the different measurements made with electrons traversing matter it becomes useful the knowledge of its transmission through that medium, their paths and their angular distribution through matter so as to process and get information about the traversed medium and to improve and innovate the techniques that employ electrons, as medical applications or materials irradiation. This work presents a simulation of the transport of beams of electrons and positrons through thin foils using an analog Monte Carlo code that simulates in a detailed way every electron movement or interaction in matter. As those particles penetrate thin absorbers it has been assumed that they interact with matter only through elastic scattering, with negligible energy loss. This type of interaction has been described quite precisely because its angular form influences very much the angular distribution of electrons and positrons in matter. With this code it has been calculated the number of particles, with energies between 100 and 3000 keV, that are transmitted through different media of various thicknesses as well as its angular distribution, showing a good agreement with experimental data. The discrepancies are less than 5% for thicknesses lower than about 30% of the corresponding range in the tested material. As elastic scattering is very anisotropic, angular distributions resemble a collimated incident beam for very thin foils becoming slowly more isotropic when absorber thickness is increased. (author)

  14. Design of a transmission electron positron microscope

    International Nuclear Information System (INIS)

    Doyama, Masao; Inoue, M.; Kogure, Y.; Hayashi, Y.; Yoshii, T.; Kurihara, T.; Tsuno, K.

    2003-01-01

    This paper reports the plans and design of positron-electron microscopes being built at KEK (High Energy Accelerator Research Organization), Tsukuba, Japan. A used electron microscope is altered. The kinetic energies of positrons produced by accelerators or by nuclear decays are not a unique value but show a spread over in a wide range. Positron beam is guided to a transmission electron microscope (JEM100SX). Positrons are moderated by a tungsten foil, are accelerated and are focused on a nickel sheet. The monochromatic focused beam is injected into an electron microscope. The focusing and aberration of positrons are the same as electrons in a magnetic system which are used in commercial electron microscopes. Imaging plates are used to record positron images for the transmission electron microscope. (author)

  15. Positron deep level transient spectroscopy — a new application of positron annihilation to semiconductor physics

    Science.gov (United States)

    Beling, C. D.; Fung, S.; Au, H. L.; Ling, C. C.; Reddy, C. V.; Deng, A. H.; Panda, B. K.

    1997-05-01

    Recent positron mobility and lifetime measurements made on ac-biased metal on semi-insulating GaAs junctions, which have identified the native EL2 defect through a determination of the characteristic ionization energy of the donor level, are reviewed. It is shown that these measurements point towards a new spectroscopy, tentatively named positron-DLTS (deep level transient spectroscopy), that is the direct complement to conventional DLTS in that it monitors transients in the electric field of the depletion region rather than the inversely related depletion width, as deep levels undergo ionization. In this new spectroscopy, which may be applied to doped material by use of a suitable positron beam, electric field transients are monitored through the Doppler shift of the annihilation radiation resulting from the drift velocity of the positron in the depletion region. Two useful extensions of the new spectroscopy beyond conventional capacitance-DLTS are suggested. The first is that in some instances information on the microstructure of the defect causing the deep level may be inferred from the sensitivity of the positron to vacancy defects of negative and neutral charge states. The second is that the positron annihilation technique is intrinsically much faster than conventional DLTS with the capability of observing transients some 10 6 times faster, thus allowing deep levels (and even shallow levels) to be investigated without problems associated with carrier freeze-out.

  16. Positron probes of the Ge(1 0 0) surface: The effects of surface reconstructions and electron-positron correlations on positron trapping and annihilation characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Fazleev, N.G. [Department of Physics, University of Texas at Arlington, Box 19059, Arlington, TX 76019-0059 (United States) and Department of Physics, Kazan State University, Kazan 420008 (Russian Federation)]. E-mail: Fazleev@uta.edu; Jung, E. [Department of Physics, University of Texas at Arlington, Box 19059, Arlington, TX 76019-0059 (United States); Weiss, A.H. [Department of Physics, University of Texas at Arlington, Box 19059, Arlington, TX 76019-0059 (United States)

    2007-08-15

    Positron annihilation induced Auger electron spectroscopy (PAES) has been applied to study the Ge(1 0 0) surface. The high-resolution PAES spectrum from the Ge(1 0 0) surface displays several strong Auger peaks corresponding to M{sub 4,5}N{sub 1}N{sub 2,3}, M{sub 2,3}M{sub 4,5}M{sub 4,5}, M{sub 2,3}M{sub 4,5}V and M{sub 1}M{sub 4,5}M{sub 4,5} Auger transitions. The integrated peak intensities of Auger transitions are used to obtain experimental annihilation probabilities for the Ge 3d and 3p core level electrons. These experimental results are analyzed by performing calculations of positron surface states and annihilation characteristics of surface trapped positrons with relevant Ge core-level electrons for the non-reconstructed and reconstructed Ge(1 0 0)-p(2 x 1), Ge(1 0 0)-p(2 x 2) and Ge(1 0 0)-c(4 x 2) surfaces. It is found that the positron surface state wave function extends into the Ge lattice in the regions where atoms are displaced from their ideal terminated positions due to reconstructions. Estimates of the positron binding energy and the positron annihilation characteristics reveal their sensitivity to the specific atomic structure of the topmost layers of Ge(1 0 0). A comparison with PAES data reveals an agreement with theoretical core annihilation probabilities for the Auger transitions considered.

  17. Comparison of iron and tungsten absorber structures for an analog hadron calorimeter

    International Nuclear Information System (INIS)

    Guenter, Clemens

    2015-05-01

    Future electron-positron-collider experiments will require unprecedented jet-energy resolution to complete their physics programs. This can only be achieved with novel approaches to calorimetry. One of these novel approaches is the Particle Flow Algorithm, which uses the best suited sub-detector to measure the energy of the particles produced by the electronpositron collision. The CALICE Collaboration evaluates different read-out technologies for Particle Flow Calorimeters. This thesis describes the comparison of two different absorber materials, iron and tungsten, for the CALICE Analog Hadron Calorimeter. It is described how test-beam data, that have been recorded in the range from 2 GeV to 10 GeV with the Analog Hadron Calorimeter are calibrated, and how samples are selected containing showers from just one particle type. The data are then compared to simulations, and the remaining disagreement between data and simulation is discussed. The validated simulations are then used to decompose the showers into different fractions. These fractions are compared for the two absorber materials to understand the impact of the absorber material choice on the calorimeter performance.

  18. Dynamic behavior of ion acoustic waves in electron-positron-ion magnetoplasmas with superthermal electrons and positrons

    Science.gov (United States)

    Saha, Asit; Pal, Nikhil; Chatterjee, Prasanta

    2014-10-01

    The dynamic behavior of ion acoustic waves in electron-positron-ion magnetoplasmas with superthermal electrons and positrons has been investigated in the framework of perturbed and non-perturbed Kadomtsev-Petviashili (KP) equations. Applying the reductive perturbation technique, we have derived the KP equation in electron-positron-ion magnetoplasma with kappa distributed electrons and positrons. Bifurcations of ion acoustic traveling waves of the KP equation are presented. Using the bifurcation theory of planar dynamical systems, the existence of the solitary wave solutions and the periodic traveling wave solutions has been established. Two exact solutions of these waves have been derived depending on the system parameters. Then, using the Hirota's direct method, we have obtained two-soliton and three-soliton solutions of the KP equation. The effect of the spectral index κ on propagations of the two-soliton and the three-soliton has been shown. Considering an external periodic perturbation, we have presented the quasi periodic behavior of ion acoustic waves in electron-positron-ion magnetoplasmas.

  19. Dynamic behavior of ion acoustic waves in electron-positron-ion magnetoplasmas with superthermal electrons and positrons

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Asit, E-mail: asit-saha123@rediffmail.com, E-mail: prasantachatterjee1@rediffmail.com [Department of Mathematics, Sikkim Manipal Institute of Technology, Majitar, Rangpo, East-Sikkim 737136 (India); Department of Mathematics, Siksha Bhavana, Visva Bharati University, Santiniketan-731235 (India); Pal, Nikhil; Chatterjee, Prasanta, E-mail: asit-saha123@rediffmail.com, E-mail: prasantachatterjee1@rediffmail.com [Department of Mathematics, Siksha Bhavana, Visva Bharati University, Santiniketan-731235 (India)

    2014-10-15

    The dynamic behavior of ion acoustic waves in electron-positron-ion magnetoplasmas with superthermal electrons and positrons has been investigated in the framework of perturbed and non-perturbed Kadomtsev-Petviashili (KP) equations. Applying the reductive perturbation technique, we have derived the KP equation in electron-positron-ion magnetoplasma with kappa distributed electrons and positrons. Bifurcations of ion acoustic traveling waves of the KP equation are presented. Using the bifurcation theory of planar dynamical systems, the existence of the solitary wave solutions and the periodic traveling wave solutions has been established. Two exact solutions of these waves have been derived depending on the system parameters. Then, using the Hirota's direct method, we have obtained two-soliton and three-soliton solutions of the KP equation. The effect of the spectral index κ on propagations of the two-soliton and the three-soliton has been shown. Considering an external periodic perturbation, we have presented the quasi periodic behavior of ion acoustic waves in electron-positron-ion magnetoplasmas.

  20. Simulation of the annihilation emission of galactic positrons

    International Nuclear Information System (INIS)

    Gillard, W.

    2008-01-01

    Positrons annihilate in the central region of our Galaxy. This has been known since the detection of a strong emission line centered on an energy of 511 keV in the direction of the Galactic center. This gamma-ray line is emitted during the annihilation of positrons with electrons from the interstellar medium. The spectrometer SPI, onboard the INTEGRAL observatory, performed spatial and spectral analyses of the positron annihilation emission. This thesis presents a study of the Galactic positron annihilation emission based on models of the different interactions undergone by positrons in the interstellar medium. The models are relied on our present knowledge of the properties of the interstellar medium in the Galactic bulge, where most of the positrons annihilate, and of the physics of positrons (production, propagation and annihilation processes). In order to obtain constraints on the positrons sources and physical characteristics of the annihilation medium, we compared the results of the models to measurements provided by the SPI spectrometer. (author)

  1. Positron probes for mechanical fatigue detection system

    International Nuclear Information System (INIS)

    Holt, W.H.; Mock, W. Jr.

    1976-01-01

    The invention comprises positron-emitting probes for use in testing samples of metals for fatique by positron annihilation techniques comprising a substrate made from the same material as the test sample, positron-emitting material supported by one surface of the substrate, and a cover for the emitting material, the cover is sealed to the substrate and is of such thinness and density as to provide a window through which positron passage is unimpeded

  2. Potential Requirement of Positron Emission Tomography Apparatuses in Asia and Latin America Including Mexico

    International Nuclear Information System (INIS)

    Watanabe, Naoyuki; Padhy, Ajit Kumar; Oku, Shinya; Sasaki, Yasuhito

    2013-01-01

    The number of positron emission tomography (PET) machines has been increasing in regions of East-, Southeast-, and South-Asia as well as in Latin America including Mexico. This study was performed to assess the potential requirement of PET machines in 19 countries which already use PET in the aforementioned regions. Data on the number of PET machines and internationally available characteristics of the restrictive countries such as the land area, the total population, the gross national income (GNI), and the average life span of inhabitants were obtained from IAEA, UN, WB, and WHO. Correlation between the number of PET machines and the characteristics of each country was evaluated. The potentially required number of PET machines, which was obtained by adjusting the number of PET machines with statistically significant, correlative characteristics of each country, standardized on the state of Japan, were compared. The number of PET machines could be significantly correlated to the GNI of a country and the average life span of its inhabitants (P < 0.05). Based on Japan, most of the countries in the regions would require considerably more PET machines. With installation of the potentially required number of PET machines in each of the countries, the number of PET machine per 10 6 population would increase by 1.1- to 12-fold, in comparison with the current situation. With regards to the potentially required number of PET machines, most of the countries in these regions may require a considerable increase of PET machines. Nevertheless, some countries in the Asia seem to require outside assistance such as international support in order to introduce PET and enhance the efficacy of their health services

  3. Defect characterization with positron annihilation

    International Nuclear Information System (INIS)

    Granatelli, L.; Lynn, K.G.

    1980-01-01

    Positron annihilation in metal crystals is reviewed. A brief introduction to the positron annihilation technique is presented first. Then the ability of the positron technique to perform microstructural characterization of four types of lattice defects (vacancies, voids, dislocations, grain boundaries) is discussed. It is frequently not possible to obtain samples that contain only one type of defect in nonnegligible concentrations. Such situations exist for some alloys and for fatigued metal samples. Finally, the current limitations and some future prospects of the technique are presented. 79 references, 14 figures, 1 table

  4. Fundamentals of positron emission tomography

    International Nuclear Information System (INIS)

    Ostertag, H.

    1989-01-01

    Positron emission tomography is a modern radionuclide method of measuring physiological quantities or metabolic parameters in vivo. The methods is based on: (1) Radioactive labelling with positron emitters; (2) the coincidence technique for the measurement of the annihilation radiation following positron decay; (3) analysis of the data measured using biological models. The basic aspects and problems of the method are discussed. The main fields of future research are the synthesis of new labelled compounds and the development of mathematical models of the biological processes to be investigated. (orig.) [de

  5. Atomic collisions involving pulsed positrons

    DEFF Research Database (Denmark)

    Merrison, J. P.; Bluhme, H.; Field, D.

    2000-01-01

    Conventional slow positron beams have been widely and profitably used to study atomic collisions and have been instrumental in understanding the dynamics of ionization. The next generation of positron atomic collision studies are possible with the use of charged particle traps. Not only can large...... instantaneous intensities be achieved with in-beam accumulation, but more importantly many orders of magnitude improvement in energy and spatial resolution can be achieved using positron cooling. Atomic collisions can be studied on a new energy scale with unprecedented precion and control. The use...

  6. The properties of helium atoms and positrons as impurities in metals

    International Nuclear Information System (INIS)

    Pendry, J.B.

    1980-01-01

    Topics covered include: (A) atoms in simple metals: (1) the highly repulsive e - /He interaction and its consequences for binding energies in simple metals; (2) binding energy calculations for jellium and their implications for validity of pair-potential He/M interactions; and (3) the need for experimental data on high negative binding energy systems: (B) low energy positrons in simple metals: (1) behaviour of the positron especially its range (< 100A); (2) consequences for experiments on voids; and (3) possibility for non-destructive depth profiling of defect concentration. (author)

  7. Positron annihilation spectroscopy for the determination of thickness and defect profile in thin semiconductor layers

    Science.gov (United States)

    Zubiaga, A.; García, J. A.; Plazaola, F.; Tuomisto, F.; Zúñiga-Pérez, J.; Muñoz-Sanjosé, V.

    2007-05-01

    We present a method, based on positron annihilation spectroscopy, to obtain information on the defect depth profile of layers grown over high-quality substrates. We have applied the method to the case of ZnO layers grown on sapphire, but the method can be very easily generalized to other heterostructures (homostructures) where the positron mean diffusion length is small enough. Applying the method to the ratio of W and S parameters obtained from Doppler broadening measurements, W/S plots, it is possible to determine the thickness of the layer and the defect profile in the layer, when mainly one defect trapping positron is contributing to positron trapping at the measurement temperature. Indeed, the quality of such characterization is very important for potential technological applications of the layer.

  8. Construction report of the PF slow-positron source. 1

    International Nuclear Information System (INIS)

    Enomoto, Atsushi; Kurihara, Toshikazu; Kobayashi, Hitoshi

    1993-12-01

    The slow positron source utilizing the electron beam of the 2.5 GeV electron beam accelerator which is the synchrotron radiation injector is being constructed. The outline of the project and the present state of construction are reported. As of November, 1993, by injecting the electron beam of about 10 W to the targets for producing positrons, the slow positrons of 4 x 10 4 e + /s has been obtained in the laboratory. Finally, with the electron beam of 30 kW, it is aimed at to obtain the slow positron beam of 2 x 10 9 e + /s. In the slow positron source, the electron beam from the 2.5 GeV linear accelerator is used as the primary beam. This beam is led to the target with electromagnets. Radiation shields were strengthened, and the electrostatic lens system was attached to efficiently extract and send out slow positrons. The conveying system for slow positrons is explained. Primary electron beam, target and moderator for producing slow positrons, the change to continuous current of pulsed slow positron beam and the heightening of luminance of slow positron beam, and the experiment on the utilization of slow positron beam, and the control system for positron conveyance path are reported. (K.I.)

  9. A study of positron irradiated porous silicon

    International Nuclear Information System (INIS)

    Huang Yuanming; Xue Qing; Zhai Baogai; Xu Aijun; Liu Shewen; Yu Weizhong

    1998-01-01

    The effect of positron irradiation on photoluminescence (PL) of porous silicon has been studied. After four hour positron irradiation, the red PL spectrum of porous silicon blue shifts into greenish spectral region, and a higher energy luminescence band is introduced into this blueshifted spectrum. The fourier transform infrared absorption experiment shows that the positron irradiation can cause further oxidization of porous silicon. A possible mechanism causing this change of PL spectra after positron irradiation is suggested

  10. Nuclear-charge and positron-energy dependence of the single-quantum annihilation of positrons

    International Nuclear Information System (INIS)

    Palathingal, J.C.; Asoka-Kumar, P.; Lynn, K.G.; Wu, X.Y.

    1995-01-01

    We report an experimental study of the single-quantum annihilation of positrons in a number of elements having atomic numbers between 49 and 90, utilizing a monoenergetic positron beam. Measurements were made of the differential cross sections for the forward direction for the K, L, and M atomic shells in targets of Th, Pb, Au, Hf, Gd, and In, having thicknesses that vary between 2.7 and 4.4 mg/cm 2 . A shielded HPGe detector of high relative photopeak efficiency was used for recording the photon spectrum. Values for the individual atomic shells were obtained in the positron kinetic-energy range 1.02--2.24 MeV. It was observed that the differential cross sections measured for the forward direction varied with energy for each major shell almost alike so that the shell ratios appeared to remain constant while the positron energy varied. The dependence of the cross section on the atomic number Z of the target element was tested for each of the major shells at various energies of measurement. It was seen that the cross sections follow a Z ν relation with ν∼5.1 as the exponent for the K shell. For the higher shells, the exponent is approximately 6.4, which is significantly larger. It was also noted that this pattern is fairly independent of the positron energy. The results on the Z dependence are seen to be clearly at variance with the most updated theoretical predictions

  11. Intra-operative nuclear imaging based on positron-emitting radiotracers

    International Nuclear Information System (INIS)

    Shakir, Dzhoshkun Ismail

    2014-01-01

    Positron-emitting radiotracers are an important part of nuclear medical imaging processes. Besides the very famous glucose analog [ 18 F]FDG, many not so well known ones exist, among them the particularly interesting amino acid-based tracers like [ 18 F]FET. Although peri-operative imaging with positron-emitting radiotracers has become state-of- the-art in cases of many types of cancer, their capability is not fully exploited in the operating room yet. In this thesis we explore two intra-operative nuclear imaging modalities exploiting different aspects of positron radiation towards quality assurance in challenging surgical treatment scenarios. The first modality freehand PET provides a tomographic image of a volume of interest and aims at minimizing invasiveness by assisting the surgeon in pinpointing target structures marked with a radiotracer. The second imaging modality epiphanography generates an image of the radiotracer distribution on a surface of interest and aims at providing a means for improving the control of tumor resection margins. The word epiphanography is a compound of the Greek words επιφανεια (epiphaneia) for surface and ζωγραφια (ographia) for image, and hence means the image of the surface similar to the compound τομοζ (tomos) for slice/volume and ζωγραφια (ographia) for image, meaning the image of the volume, i.e. tomography. To our knowledge this is the first use of the word epiphanography in the context of nuclear medical imaging. In this thesis we present our approach to modeling, developing and calibrating these two novel imaging modalities. In addition, we present our work towards their clinical integration. In the case of freehand PET, we have already acquired the first intra-operative datasets of a patient. We present this first experience in the operating room together with our phantom studies. In the case of epiphanography, we present our phantom studies with neurosurgeons towards the integration of this

  12. When Reasoning Modifies Memory: Schematic Assimilation Triggered by Analogical Mapping

    Science.gov (United States)

    Vendetti, Michael S.; Wu, Aaron; Rowshanshad, Ebi; Knowlton, Barbara J.; Holyoak, Keith J.

    2014-01-01

    Analogical mapping highlights shared relations that link 2 situations, potentially at the expense of information that does not fit the dominant pattern of correspondences. To investigate whether analogical mapping can alter subsequent recognition memory for features of a source analog, we performed 2 experiments with 4-term proportional analogies…

  13. Bulk Materials Analysis Using High-Energy Positron Beams

    International Nuclear Information System (INIS)

    Glade, S C; Asoka-Kumar, P; Nieh, T G; Sterne, P A; Wirth, B D; Dauskardt, R H; Flores, K M; Suh, D; Odette, G.R.

    2002-01-01

    This article reviews some recent materials analysis results using high-energy positron beams at Lawrence Livermore National Laboratory. We are combining positron lifetime and orbital electron momentum spectroscopic methods to provide electron number densities and electron momentum distributions around positron annihilation sites. Topics covered include: correlation of positron annihilation characteristics with structural and mechanical properties of bulk metallic glasses, compositional studies of embrittling features in nuclear reactor pressure vessel steel, pore characterization in Zeolites, and positron annihilation characteristics in alkali halides

  14. Investigation and realization of a slow-positron beam

    International Nuclear Information System (INIS)

    Ruiz, Nicolas

    2011-01-01

    This research thesis first proposes a presentation of the GBAR project (Gravitational Behaviour of Anti-hydrogen at Rest) within which this research took place, and which aims at performing the first direct test of the Weak Equivalence Principle on anti-matter by studying the free fall of anti-hydrogen atoms in the Earth gravitational field. The author presents different aspects of this project: scientific objective, experiment principle and structure, detailed structure (positron beam, positron trap, positron/positronium conversion, anti-proton beam, trapping, slowing down and neutralisation of anti-hydrogen ions). The author then reports the design of the positron beam: study of source technology, studies related to the fast positron source, design of the low positron line (approach, functions, simulations, technology). The two last chapters report the construction and the characterization of the slow-positron line [fr

  15. Evaluation of scintillators and semiconductor detectors to image three-photon positron annihilation for positron emission tomography

    International Nuclear Information System (INIS)

    Abuelhia, E.; Spyrou, N.M.; Kacperski, K.; College University, Middlesex Hospital, London

    2008-01-01

    Positron emission tomography (PET) is rapidly becoming the main nuclear imaging modality of the present century. The future of PET instrumentation relies on semiconductor detectors because of their excellent characteristics. Three-photon positron annihilation has been recently investigated as a novel imaging modality, which demands the crucial high energy resolution of semiconductor detector. In this work the evaluation of the NaI(Tl) scintillator and HPGe and CdZTe semiconductor detectors, to construct a simple three-photon positron annihilation scanner has been explored. The effect of detector and scanner size on spatial resolution (FWHM) is discussed. The characteristics: energy resolution versus count rate and point-spread function of the three-photon positron annihilation image profile from triple coincidence measurements were investigated. (author)

  16. Compression of positron clouds using rotating wall electric fields

    International Nuclear Information System (INIS)

    Werf, Dirk Peter van der; Isaac, Christopher Aled; Baker, Christopher John; Mortensen, Timothy; Charlton, Michael

    2012-01-01

    An asymmetric dipolar rotating electric field can be used to compress a trapped cloud of positrons when applied with a frequency close that of their axial bounce, and in the presence of a low pressure molecular gas to provide cooling. Measurements of the compression rate and associated parameters are presented and compared with results of a theory we have developed. The latter treats positron behaviour in a perfect Penning trap potential, in the presence of the rotating field, with the cooling modelled in the Stokes viscous drag approximation. Good agreement between the theory and experiment has been found, which has allowed us to identify the phenomenon as a new form of sideband cooling.

  17. Magnetohydrodynamic spin waves in degenerate electron-positron-ion plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Mushtaq, A. [TPPD, PINSTECH Nilore, 44000 Islamabad (Pakistan); National Center for Physics, Shahdrah Valley Road, 44000 Islamabad (Pakistan); Maroof, R.; Ahmad, Zulfiaqr [Institute of Physics and Electronics, University of Peshawar, 25000 Peshawar (Pakistan); Qamar, A. [National Center for Physics, Shahdrah Valley Road, 44000 Islamabad (Pakistan); Institute of Physics and Electronics, University of Peshawar, 25000 Peshawar (Pakistan)

    2012-05-15

    Low frequency magnetosonic waves are studied in magnetized degenerate electron-positron-ion plasmas with spin effects. Using the fluid equations of magnetoplasma with quantum corrections due to the Bohm potential, temperature degeneracy, and spin magnetization energy, a generalized dispersion relation for oblique magnetosonic waves is derived. Spin effects are incorporated via spin force and macroscopic spin magnetization current. For three different values of angle {theta}, the generalized dispersion relation is reduced to three different relations under the low frequency magnetohydrodynamic assumptions. It is found that the effect of quantum corrections in the presence of positron concentration significantly modifies the dispersive properties of these modes. The importance of the work relevant to compact astrophysical bodies is pointed out.

  18. Positron emission tomography study on pancreatic somatostatin receptors in normal and diabetic rats with 68Ga-DOTA-octreotide: a potential PET tracer for beta cell mass measurement.

    Science.gov (United States)

    Sako, Takeo; Hasegawa, Koki; Nishimura, Mie; Kanayama, Yousuke; Wada, Yasuhiro; Hayashinaka, Emi; Cui, Yilong; Kataoka, Yosky; Senda, Michio; Watanabe, Yasuyoshi

    2013-12-06

    Diabetes mellitus (DM) is a metabolic disorder characterized by hyperglycemia, and the loss or dysfunction of pancreatic beta cells has been reported before the appearance of clinical symptoms and hyperglycemia. To evaluate beta cell mass (BCM) for improving the detection and treatment of DM at earlier stages, we focused on somatostatin receptors that are highly expressed in the pancreatic beta cells, and developed a positron emission tomography (PET) probe derived from octreotide, a metabolically stable somatostatin analog. Octreotide was conjugated with 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA), a chelating agent, and labeled with (68)Gallium ((68)Ga). After intravenous injection of (68)Ga-DOTA-octreotide, a 90-min emission scan of the abdomen was performed in normal and DM model rats. The PET studies showed that (68)Ga-DOTA-octreotide radioactivity was highly accumulated in the pancreas of normal rats and that the pancreatic accumulation was significantly reduced in the rats administered with an excess amount of unlabeled octreotide or after treatment with streptozotocin, which was used for the chemical induction of DM in rats. These results were in good agreement with the ex vivo biodistribution data. These results indicated that the pancreatic accumulation of (68)Ga-DOTA-octreotide represented specific binding to the somatostatin receptors and reflected BCM. Therefore, PET imaging with (68)Ga-DOTA-octreotide could be a potential tool for evaluating BCM. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Preclinical evaluation of a positron emitting progestin ([18F]fluoro-16 alpha-methyl-19-norprogesterone) for imaging progesterone receptor positive tumours with positron emission tomography

    NARCIS (Netherlands)

    Verhagen, Aalt; Luurtsema, Gert; PESSER, JW; DEGROOT, TJ; OOSTERHUIS, JW; Vaalburg, Willem; Wouda, S.

    Three 21-fluoro-progestins were investigated as potential imaging agents for the in vivo assessment of human progesterone receptor positive neoplasms with positron emission tomography. In competitive binding assays these compounds demonstrated high specificity, competing only for progesterone

  20. The rise in the positron fraction. Distance limits on positron point sources from cosmic ray arrival directions and diffuse gamma-rays

    Energy Technology Data Exchange (ETDEWEB)

    Gebauer, Iris; Bentele, Rosemarie [Karlsruhe Institute of Technology, Karlsruhe (Germany)

    2016-07-01

    The rise in the positron fraction as observed by AMS and previously by PAMELA, cannot be explained by the standard paradigm of cosmic ray transport in which positrons are produced by cosmic-ray-gas interactions in the interstellar medium. Possible explanations are pulsars, which produce energetic electron-positron pairs in their rotating magnetic fields, or the annihilation of dark matter. Here we assume that these positrons originate from a single close-by point source, producing equal amounts of electrons and positrons. The propagation and energy losses of these electrons and positrons are calculated numerically using the DRAGON code, the source properties are optimized to best describe the AMS data. Using the FERMI-LAT limits on a possible dipole anisotropy in electron and positron arrival directions, we put a limit on the minimum distance of such a point source. The energy losses that these energetic electrons and positrons suffer on their way through the galaxy create gamma ray photons through bremsstrahlung and Inverse Compton scattering. Using the measurement of diffuse gamma rays from Fermi-LAT we put a limit on the maximum distance of such a point source. We find that a single electron positron point source powerful enough to explain the locally observed positron fraction must reside between 225 pc and 3.7 kpc distance from the sun and compare to known pulsars.

  1. Imaging Atherosclerosis with Hybrid Positron Emission Tomography/Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Ripa, Rasmus Sejersten; Kjær, Andreas

    2015-01-01

    Noninvasive imaging of atherosclerosis could potentially move patient management towards individualized triage, treatment, and followup. The newly introduced combined positron emission tomography (PET) and magnetic resonance imaging (MRI) system could emerge as a key player in this context. Both...

  2. Natural analogs for Yucca Mountain

    International Nuclear Information System (INIS)

    Murphy, W.M.

    1995-01-01

    High-level radioactive waste in the US, spent fuels from commercial reactors and nuclear materials generated by defense activities, will remain potentially hazardous for thousands of years. Demonstrable long-term stability of certain geologic and geochemical systems motivates and sustains the concept that high-level waste can be safely isolated in geologic repositories for requisite periods of time. Each geologic repository is unique in its properties and performance with reguard to isolation of nuclear wastes. Studies of processes analogous to waste-form alteration and radioelement transport in environments analogous to Yucca Mountain are being conducted at two sites, described in this article to illustrate uses of natural analog data: the Nopal I uranium deposit in the Sierra Pena Blanca, Mexico, and the Akrotiri archaeological site on the island of Santorini, Greece

  3. Studies of positron induced luminescence from polymers

    International Nuclear Information System (INIS)

    Xu, J.; Hulett, L.D. Jr.; Lewis, T.A.; Tolk, N.H.

    1994-01-01

    Light emission from polymers (anthracene dissolved in polystryrene) induced by low-energy positrons and electrons has been studied. Results indicate a clear difference between optical emissions under positron and electron bombardment. The positron-induced luminescence spectrum is believed to be generated by both collisional and annihilation processes

  4. Cardiac positron tomography

    International Nuclear Information System (INIS)

    Geltmann, E.M.; Roberts, R.; Sobel, B.E.

    1980-01-01

    Positron emission tomography (PET) performed after the administration of the positron-emitting radionuclides carbon-11 ( 11 C), nitrogen-13 ( 13 N), oxygen-15 ( 15 O) and fluorine-18 ( 18 F) has permitted the improved noninvasive assessment of the regional myocardial metabolism of normal physiologic substrates and intermediates and their cogeners. In experimental animals, the rate of oxidation of 11 C-palmitate correlates closely with other indexes of oxygen consumption, and the extraction of 11 C-palmitate (like that of 18 F-fatty acids and 18 F-fluoredoxyglucose) ist markedly diminished in regions of myocardial ischemia. In both experimental animals and in patients, myocardial infarct site and size, determined by positron emission tomography after the intravenous injection of 11 C-palmitate, correlate closely with the electrocardiographic infarct locus and enzymatically estimated infarct size as well as with the location and extent of regional left ventricular wall motion abnormalities. PET offers promise for assessment of flow as well despite the complexities involved. PET with 13 NH 3 appears to provide one useful qualitative index, although this tracer ist actively metabolized. Because of the quantitative capabilities of positron emission tomography and the rapid progress which is being made in the development of fast scan, multi-slice, and gated instrumentation, this technique is likely to facilitate improved understanding and characterization of regional myocardial metabolism and blood flow in man under physiological and pathophysiological conditions. (orig.) [de

  5. Analogy between electromagnetic potentials and wave-like dynamic variables with connections to quantum theory

    Science.gov (United States)

    Yang, Chen

    2018-05-01

    The transitions from classical theories to quantum theories have attracted many interests. This paper demonstrates the analogy between the electromagnetic potentials and wave-like dynamic variables with their connections to quantum theory for audiences at advanced undergraduate level and above. In the first part, the counterpart relations in the classical electrodynamics (e.g. gauge transform and Lorenz condition) and classical mechanics (e.g. Legendre transform and free particle condition) are presented. These relations lead to similar governing equations of the field variables and dynamic variables. The Lorenz gauge, scalar potential and vector potential manifest a one-to-one similarity to the action, Hamiltonian and momentum, respectively. In the second part, the connections between the classical pictures of electromagnetic field and particle to quantum picture are presented. By characterising the states of electromagnetic field and particle via their (corresponding) variables, their evolution pictures manifest the same algebraic structure (isomorphic). Subsequently, pictures of the electromagnetic field and particle are compared to the quantum picture and their interconnections are given. A brief summary of the obtained results are presented at the end of the paper.

  6. Positron lifetime experiments in indium selenide

    International Nuclear Information System (INIS)

    Cruz, R.M. de la; Pareja, R.

    1988-01-01

    Positron lifetime experiments have been performed on as-grown samples which had been isochronally annealed up to 820 K and plastically deformed and these experiments yield a constant lifetime of 282 ± 2 ps which is attributed to bulk positron states in InSe. Electron-irradiated samples exhibit a two-component spectrum, revealing the presence of positron traps which anneal out at about 330 K. The nature of the native shallow donors in InSe is discussed in the light of the results, which support the idea that native donor centres are probably interstitial In atoms rather than Se vacancies. Positron trapping observed in the electron-irradiated samples is attributed to defects related to In vacancies. (author)

  7. Analogical scaffolding: Making meaning in physics through representation and analogy

    Science.gov (United States)

    Podolefsky, Noah Solomon

    This work reviews the literature on analogy, introduces a new model of analogy, and presents a series of experiments that test and confirm the utility of this model to describe and predict student learning in physics with analogy. Pilot studies demonstrate that representations (e.g., diagrams) can play a key role in students' use of analogy. A new model of analogy, Analogical Scaffolding, is developed to explain these initial empirical results. This model will be described in detail, and then applied to describe and predict the outcomes of further experiments. Two large-scale (N>100) studies will demonstrate that: (1) students taught with analogies, according to the Analogical Scaffolding model, outperform students taught without analogies on pre-post assessments focused on electromagnetic waves; (2) the representational forms used to teach with analogy can play a significant role in student learning, with students in one treatment group outperforming students in other treatment groups by factors of two or three. It will be demonstrated that Analogical Scaffolding can be used to predict these results, as well as finer-grained results such as the types of distracters students choose in different treatment groups, and to describe and analyze student reasoning in interviews. Abstraction in physics is reconsidered using Analogical Scaffolding. An operational definition of abstraction is developed within the Analogical Scaffolding framework and employed to explain (a) why physicists consider some ideas more abstract than others in physics, and (b) how students conceptions of these ideas can be modeled. This new approach to abstraction suggests novel approaches to curriculum design in physics using Analogical Scaffolding.

  8. Positron lifetime study of neutron-irradiated molybdenum

    International Nuclear Information System (INIS)

    Hinode, Kenji; Tanigawa, Shoichiro; Kumakura, Hiroaki; Doyama, Masao; Shiraishi, Kensuke.

    1978-01-01

    Annealing behavior of fast-neutron-irradiated molybdenum was studied by means of positron lifetime technique. It was found that Stage III annealing can be mainly identified as the vacancy migration process from the detailed analyses of data. The void growth after successive high temperature annealings was clearly detected through the changes of positron lifetime parameters. An attempt to analyse the size distribution of voids from positron lifetime spectra was presented, and discussions on the evaluation of void concentration from positron data are also given. (author)

  9. Positron annihilation spectroscopy in materials structure studies

    International Nuclear Information System (INIS)

    Grafutin, Viktor I; Prokop'ev, Evgenii P

    2002-01-01

    A relatively new method of materials structure analysis - positron annihilation spectroscopy (PAS) - is reviewed. Measurements of positron lifetimes, the determination of positron 3γ- and 2γ-annihilation probabilities, and an investigation of the effects of different external factors on the fundamental characteristics of annihilation constitute the basis for this promising method. The ways in which the positron annihilation process operates in ionic crystals, semiconductors, metals and some condensed matter systems are analyzed. The scope of PAS is described and its prospects for the study of the electronic and defect structures are discussed. The applications of positron annihilation spectroscopy in radiation physics and chemistry of various substances as well as in physics and chemistry of solutions are exemplified. (instruments and methods of investigation)

  10. Digital positron annihilation spectrometer

    International Nuclear Information System (INIS)

    Cheng Bin; Weng Huimin; Han Rongdian; Ye Bangjiao

    2010-01-01

    With the high speed development of digital signal process, the technique of the digitization and processing of signals was applied in the domain of a broad class of nuclear technique. The development of digital positron lifetime spectrometer (DPLS) is more promising than the conventional positron lifetime spectrometer equipped with nuclear instrument modules. And digital lifetime spectrometer has many advantages, such as low noise, long term stability, flexible online or offline digital processing, simple setup, low expense, easy to setting, and more physical information. Digital constant fraction discrimination is for timing. And a new method of optimizing energy windows setting for digital positron lifetime spectrometer is also developed employing the simulated annealing for the convenient use. The time resolution is 220ps and the count rate is 200cps. (authors)

  11. Positron emission tomography imaging--technical considerations

    International Nuclear Information System (INIS)

    Muehllehner, G.; Karp, J.S.

    1986-01-01

    Positron imaging instrumentation has improved rapidly in the last few years. Scanners currently under development are beginning to approach fundamental limits set by positron range and noncolinearity effects. This report reviews the latest developments in positron emission tomography (PET) instrumentation, emphasizing the development of coding schemes that reduce the complexity and cost of high-resolution scanners. The relative benefits of using time-of-flight (TOF) information is discussed as well. 68 references

  12. Doppler Broadening of In-Flight Positron Annihilation Radiation due to Electron Momentum

    International Nuclear Information System (INIS)

    Hunt, A. W.; Cassidy, D. B.; Sterne, P. A.; Cowan, T. E.; Howell, R. H.; Lynn, K. G.; Golevchenko, J. A.

    2001-01-01

    We report the first observation of electron momentum contributions to the Doppler broadening of radiation produced by in-flight two-photon annihilation in solids. In these experiments an approximately 2.5 MeV positron beam impinged on thin polyethylene, aluminum, and gold targets. Since energetic positrons easily penetrate the nuclear Coulomb potential and do not cause a strong charge polarization, the experimental annihilation line shapes agree well with calculations based on a simple independent-particle model. Moreover, annihilations with the deepest core electrons are greatly enhanced

  13. Radiolabeling of DOTATOC with the long-lived positron emitter {sup 44}Sc

    Energy Technology Data Exchange (ETDEWEB)

    Pruszynski, Marek; Majkowska-Pilip, Agnieszka [Centre of Radiochemistry and Nuclear Chemistry, Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warszawa (Poland); Loktionova, Natalia S.; Eppard, Elisabeth [Institute of Nuclear Chemistry, Johannes Gutenberg-University of Mainz, Fritz-Strassmann-Weg 2, D-55128 Mainz (Germany); Roesch, Frank, E-mail: frank.roesch@uni-mainz.de [Institute of Nuclear Chemistry, Johannes Gutenberg-University of Mainz, Fritz-Strassmann-Weg 2, D-55128 Mainz (Germany)

    2012-06-15

    The positron-emitting radionuclide {sup 44}Sc with a half-life of 3.97 h and a {beta}{sup +} branching of 94.3% is of potential interest for clinical PET. As so far it is available from a {sup 44}Ti/{sup 44}Sc generator in Mainz, where long-lived {sup 44}Ti decays to no-carrier-added (nca) {sup 44}Sc. The {sup 44}Sc is a trivalent metal cation and should be suitable for complexation with many well established bifunctional chelators conjugated to peptides or other molecular targeting vectors. Thus, the aim of this work was to investigate the potential of {sup 44}Sc for labeling of DOTA-conjugated peptides. DOTA-D-Phe{sup 1}-Tyr{sup 3}-octreotide (DOTATOC) was used as a model molecule to study and optimize labeling procedure. Reaction parameters such as buffer conditions, concentration of peptide, pH range, reaction temperature and time were optimized. Addition of 21 nmol of DOTATOC to {sup 44}Sc in ammonium acetate buffer pH 4.0 provided labeling yields >98% within 25 min of heating in an oil-bath at 95 Degree-Sign C. This time can be reduced to 3 min only by applying microwave supported heating. {sup 44}Sc-DOTATOC was found to be stable in 0.9% NaCl, PBS pH 7.4, fetal calf and human serums, and also in the presence of competing metal cations (Fe{sup 3+}, Ca{sup 2+}, Cu{sup 2+}, Mg{sup 2+}), as well as other ligand competitors, like EDTA and DTPA, even after almost 25 h incubation at 37 Degree-Sign C. Present study shows that nca {sup 44}Sc forms stable complexes with the macrocyclic ligand DOTA and that {sup 44}Sc-DOTATOC and analog targeting vectors may be synthesized for further preclinical and clinical investigations. - Highlights: Black-Right-Pointing-Pointer Labeling of somatostatin analouges with positron emitter {sup 44}Sc was tested. Black-Right-Pointing-Pointer DOTATOC was labeled with {sup 44}Sc isotope. Black-Right-Pointing-Pointer Optimal conditions for {sup 44}Sc-DOTATOC synthesis were found. Black-Right-Pointing-Pointer Stability of {sup 44}Sc

  14. Generation and application of slow positrons based on a electron LINAC

    International Nuclear Information System (INIS)

    Kurihara, Toshikazu

    2002-01-01

    History of slow positron in Institute of Materials Structure Science High Energy Accelerator Research Organization is explained. The principle of generation and application of intense positron beam is mentioned. Two sources of intense positron are radioactive decay of radioactive isotopes emitting positron and electron-positron pair creation. The radioactive decay method uses 58 Co, 64 Cu, 11 C, 13 N, 15 O and 18 F. The electron-positron pair creation method uses nuclear reactor or electron linear accelerator (LINAC). The positron experimental facility in this organization consists of electron LINAC, slow positron beam source, positron transport and experimental station. The outline of this facility is started. The intense slow positron beam is applied to research positronium work function, electron structure of surface. New method such as combination of positron lifetime measurement and slow positron beam or Auger electron spectroscopy by positron annihilation excitation and positron reemission microscope are developed. (S.Y.)

  15. Experimental Study of a Positron\\\\ Source Using Channeling

    CERN Multimedia

    Gavrykov, V; Kulibaba, V; Baier, V; Beloborodov, K; Bojenok, A; Bukin, A; Burdin, S; Dimova, T; Druzhinin, V; Dubrovin, M; Seredniakov, S; Shary, V; Strakhovenko, V; Keppler, P; Major, J; Bogdanov, A V; Potylitsin, A; Vnoukov, I; Artru, X; Lautesse, P; Poizat, J-C; Remillieux, J

    2002-01-01

    Many simulations have predicted that the yield of positrons, resulting from the interaction of fast electrons in a solid target, increases if the target is a crystal oriented with a major axis parallel to the electron beam. Tests made at Orsay and Tokyo confirmed these expectations. The experiment WA 103 concerns the determination of the main characteristics (emittance, energy spread) of a crystal positron source which could replace advantageously the conventional positron converters foreseen in some linear collider projects. The main element of the set-up is a magnetic spectrometer, using a drift chamber, where the positron trajectories are reconstructed (see Figure 1) A first run has been operated in july 2000 and the first results showed, as expected, a significant enhancement in photon and positron generation along the $$ axis of the tungsten crystal. Indications about a significant increase in the number of soft photons and positrons were also gathered : this point is of importance for the positron colle...

  16. Toward a European Network of Positron Laboratories

    Directory of Open Access Journals (Sweden)

    Karwasz Grzegorz P.

    2015-12-01

    Full Text Available Some applications of controlled-energy positron beams in material studies are discussed. In porous organic polysilicates, measurements of 3γ annihilation by Doppler broadening (DB method at the Trento University allowed to trace pore closing and filling by water vapor. In silicon coimplanted by He+ and H+, DB data combined with positron lifetime measurements at the München pulsed positron beam allowed to explain Si blistering. Presently measured samples of W for applications in thermonuclear reactors, irradiated by W+ and electrons, show vast changes of positron lifetimes, indicating complex dynamics of defects.

  17. Recent developments in the theory of positrons at surfaces

    International Nuclear Information System (INIS)

    Walker, A.B.

    1989-01-01

    Positron beams of ever brighter intensity are now establishing themselves as a novel surface probe enabling a wide variety of spectroscopies. The production of high positron intensities and exploitation of the beams depends critically on our understanding of the complex behaviour of positrons at and near surfaces. I will review progress on the theory of positron-surface interactions and of the implantation and diffusion of low energy positrons. Applications of this theory to a variety of experimental techniques such as ACAR (Angular Correlation by Annihilation Radiation) spectra, angle resolved positronium (Ps) spectroscopy, REPELS (Reemitted Positron Energy Loss Spectroscopy), LEPD (Low Energy Positron Diffraction) and measurements of defect profiles will be discussed. 24 refs. (author)

  18. Design and Characterization of a Three-Dimensional Positron Annihilation Spectroscopy System Using a Low-Energy Positron Beam

    Science.gov (United States)

    2012-03-22

    Technique Applied to Measure Oxygen -Atom Defects in 6H Silicon Carbide”. 2010. [31] Y. C. Jean , P. E. Mallon and D. M. Schrader. Principles and Applications...that result in β+ emission, by photon interactions with nuclei and subsequent pair production, or by β+ decays from radioactive isotopes made by...reactions for creating positrons [7], some of which are used to to create radioactive isotopes that β+ decay. Regardless of the positron source, positrons

  19. Cyclotrons and positron emitting radiopharmaceuticals

    International Nuclear Information System (INIS)

    Wolf, A.P.; Fowler, J.S.

    1984-01-01

    The state of the art of Positron Emission Tomography (PET) technology as related to cyclotron use and radiopharmaceutical production is reviewed. The paper discusses available small cyclotrons, the positron emitters which can be produced and the yields possible, target design, and radiopharmaceutical development and application. 97 refs., 12 tabs

  20. Positron emission tomography now and in the future

    International Nuclear Information System (INIS)

    Vaalburg, W.

    1987-01-01

    A survey is given of positron emission tomography used in nuclear medicine. The production of positron emitting radionuclides is discussed. The development of positron detectors is described. The application of positron emission tomography in cardiology, oncology and neurology is treated. The authors conclude that PET is a unique method to examine metabolic processes, although the method is still in its infancy. 7 refs.; 1 table

  1. Positron creation in superheavy quasi-molecules

    International Nuclear Information System (INIS)

    Mueller, B.

    1976-01-01

    The review of positron creation in superheavy quasi-molecules includes spontaneous positron emission from superheavy atoms, supercritical quasi-molecules, background effects, and some implications of the new ground state. 66 references

  2. Positron studies of metal-oxide-semiconductor structures

    Science.gov (United States)

    Au, H. L.; Asoka-Kumar, P.; Nielsen, B.; Lynn, K. G.

    1993-03-01

    Positron annihilation spectroscopy provides a new probe to study the properties of interface traps in metal-oxide semiconductors (MOS). Using positrons, we have examined the behavior of the interface traps as a function of gate bias. We propose a simple model to explain the positron annihilation spectra from the interface region of a MOS capacitor.

  3. In-situ positron emission of CO oxidation

    NARCIS (Netherlands)

    Vonkeman, K.A.; Jonkers, G.; Wal, van der S.W.A.; Santen, van R.A.

    1993-01-01

    Using a Neuro ECAT positron tomog., the Positron Emission computed Tomog. (PET) was utilized to image the catalytic oxidn. of CO by using CO and CO2, labeled with short lived positron emitting nuclides. Studies were performed over highly dispersed CeO2/g-Al2O3 supported Pt and Rh catalysts. With a

  4. Development and applications of time-bunched and velocity-selected positron beams

    DEFF Research Database (Denmark)

    Merrison, J.P.; Charlton, M.; Aggerholm, P.

    2003-01-01

    the buncher was used to compress positron pulses produced from an electron accelerator-based beam. Computer simulations of particle trajectories in the buncher have been performed resulting in a detailed evaluation of the factors that govern and limit the time resolution of the instrument. A sector magnet...... for propagation of the applied voltage pulse along the electrode system and to facilitate operation at frequencies up to 100 kHz. A parabolic potential distribution for time focusing was used. Tests with a dc positron beam produced from a radioactive source are described, together with measurements in which...

  5. Positron emission tomography

    International Nuclear Information System (INIS)

    Bolwig, T.G.; Haunsoe, S.; Dahlgaard Hove, J.; Hesse, B.; Hoejgard, L.; Jensen, M.; Paulson, O.B.; Hastrup Svendsen, J.; Soelvsten Soerensen, S.

    1994-01-01

    Positron emission tomography (PET) is a method for quantitative imaging of regional physiological and biochemical parameters. Positron emitting radioactive isotopes can be produced by a cyclotron, eg. the biologically important carbon ( 11 C), oxygen ( 15 O), and nitrogen ( 13 N) elements. With the tomographic principles of the PET scanner the quantitative distribution of the administered isotopes can be determined and images can be provided as well as dynamic information on blood flow, metabolism and receptor function. In neurology PET has been used for investigations on numerous physiological processes in the brain: circulation, metabolism and receptor studies. In Parkinson's disease PET studies have been able to localize the pathology specifically, and in early stroke PET technique can outline focal areas with living but non-functioning cells, and this could make it possible to intervene in this early state. With positron emission tomography a quantitative evaluation of myocardial blood flow, glucose and fatty acid metabolism can be made as well as combined assessments of blood flow and metabolism. Combined studies of blood flow and metabolism can determine whether myocardial segments with abnormal motility consist of necrotic or viable tissue, thereby delineating effects of revascularisation. In the future it will probably be possible to characterize the myocardial receptor status in different cardiac diseases. The PET technique is used in oncology for clinical as well as more basic research on tumor perfusion and metabolism. Further, tumor uptake of positron labelled cytotoxic drugs might predict the clinical benefit of treatment. (au) (19 refs.)

  6. Cyclotrons and positron emitting radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, A.P.; Fowler, J.S.

    1984-01-01

    The state of the art of Positron Emission Tomography (PET) technology as related to cyclotron use and radiopharmaceutical production is reviewed. The paper discusses available small cyclotrons, the positron emitters which can be produced and the yields possible, target design, and radiopharmaceutical development and application. 97 refs., 12 tabs. (ACR)

  7. Automatic sup sup 1 sup sup 8 F positron source supply system for a monoenergetic positron beam

    CERN Document Server

    Saito, F; Itoh, Y; Goto, A; Fujiwara, I; Kurihara, T; Iwata, R; Nagashima, Y; Hyodo, T

    2000-01-01

    A system which supplies an intense sup sup 1 sup sup 8 F (half life 110 min) positron source produced by an AVF cyclotron through sup sup 1 sup sup 8 O(p,n) sup sup 1 sup sup 8 F reaction has been constructed. Produced sup sup 1 sup sup 8 F is transferred to a low background experiment hall through a capillary. It is electro-deposited on a graphite rod and used for a source of a slow positron beam. In the meantime the next batch of target sup sup 1 sup sup 8 O water is loaded and proton irradiation proceeds. This system makes it possible to perform continuous positron beam experiments using the 18 F positron source.

  8. Detecting analogies unconsciously

    Directory of Open Access Journals (Sweden)

    Thomas Peter Reber

    2014-01-01

    Full Text Available Analogies may arise from the conscious detection of similarities between a present and a past situation. In this functional magnetic resonance imaging study, we tested whether young volunteers would detect analogies unconsciously between a current supraliminal (visible and a past subliminal (invisible situation. The subliminal encoding of the past situation precludes awareness of analogy detection in the current situation. First, participants encoded subliminal pairs of unrelated words in either one or nine encoding trials. Later, they judged the semantic fit of supraliminally presented new words that either retained a previously encoded semantic relation (‘analog’ or not (‘broken analog’. Words in analogs versus broken analogs were judged closer semantically, which reflects unconscious analogy detection. Hippocampal activity associated with subliminal encoding correlated with the behavioral measure of unconscious analogy detection. Analogs versus broken analogs were processed with reduced prefrontal but enhanced medial temporal activity. We conclude that analogous episodes can be detected even unconsciously drawing on the episodic memory network.

  9. Synthetic Curcumin Analogs as Inhibitors of β -Amyloid Peptide Aggregation: Potential Therapeutic and Diagnostic Agents for Alzheimer's Disease.

    Science.gov (United States)

    Bukhari, Syed Nasir Abbas; Jantan, Ibrahim

    2015-01-01

    There is a crucial need to develop new effective drugs for Alzheimer's disease (AD) as the currently available AD treatments provide only momentary and incomplete symptomatic relief. Amongst natural products, curcumin, a major constituent of turmeric, has been intensively investigated for its neuroprotective effect against β-amyloid (Aβ)-induced toxicity in cultured neuronal cells. The ability of curcumin to attach to Aβ peptide and prevent its accumulation is attributed to its three structural characteristics such as the presence of two aromatic end groups and their co-planarity, the length and rigidity of the linker region and the substitution conformation of these aromatics. However, curcumin failed to reach adequate brain levels after oral absorption in AD clinical trials due to its low water solubility and poor oral bioavailability. A number of new curcumin analogs that mimic the active site of the compound along with analogs that mimic the curcumin anti-amyloid effect combined with anticholinesterase effect have been developed to enhance the bioavailability, pharmacokinetics, water solubility, stability at physiological conditions and delivery of curcumin. In this article, we have summarized all reported synthetic analogs of curcumin showing effects on β-amyloid and discussed their potential as therapeutic and diagnostic agents for AD.

  10. Positron emission tomography with Positome, 2

    International Nuclear Information System (INIS)

    Nukui, Hideaki; Yamamoto, Y.L.; Thompson, C.J.; Feindel, W.

    1979-01-01

    Positron emission tomography with Positome II using 68 Ga-EDTA was performed in cases with brain tumor and cerebral arteriovenous malformation. A significant focal uptake in static study and hemodynamic changes in dynamic study were noted in all cases except one case with intracranial lipoma. Comparing this method with sup(99m) Tc-pertechnetate cerebral image study and computerized axial tomography, the diagnostic rate for detecting brain tumor was almost equal in all of these three methods. However, detecting and localizing was easier and clearer in static positron emission tomography with 68 Ga-EDTA than in sup(99m) Tc-pertechnetate cerebral image and computerized axial tomography without infusion of contrast medium. Furthermore, static positron emission tomography with 68 Ga-EDTA was superior to computerized axial tomography without infusion of contrast medium for detecting cerebral arteriovenous malformation. Concerning dynamic positron emission tomography with 68 Ga-EDTA, semiquantitative values obtained by this method correlated well with findings of computerized axial tomography and was thought to be more precise and in detail than the findings of sup(99m) Tc-pertechnetate cerebral image study. Summation of the previous studies about dynamic positron emission tomography with 77 Kr in occlusive cerebrovascular disease is also reported. In conclusion, static positron emission tomography with 68 Ga-EDTA is a very useful diagnostic method for detecting and localizing brain tumor and cerebral arteriovenous malformation without any attendant complications. Furthermore, a good combination of static and dynamic positron emission tomography and computerized axial tomography appear to be outstandingly effective for not only detecting the lesion but also understanding the pathophysiological aspect in cases with various intracranial lesions. (author)

  11. Generation and application of slow positrons based on a electron LINAC

    CERN Document Server

    Kurihara, T

    2002-01-01

    History of slow positron in Institute of Materials Structure Science High Energy Accelerator Research Organization is explained. The principle of generation and application of intense positron beam is mentioned. Two sources of intense positron are radioactive decay of radioactive isotopes emitting positron and electron-positron pair creation. The radioactive decay method uses sup 5 sup 8 Co, sup 6 sup 4 Cu, sup 1 sup 1 C, sup 1 sup 3 N, sup 1 sup 5 O and sup 1 sup 8 F. The electron-positron pair creation method uses nuclear reactor or electron linear accelerator (LINAC). The positron experimental facility in this organization consists of electron LINAC, slow positron beam source, positron transport and experimental station. The outline of this facility is started. The intense slow positron beam is applied to research positronium work function, electron structure of surface. New method such as combination of positron lifetime measurement and slow positron beam or Auger electron spectroscopy by positron annihil...

  12. Radiopharmaceuticals in positron emission tomography: Radioisotope productions and radiolabelling procedures at the Austin and Repatriation Medical Centre

    International Nuclear Information System (INIS)

    Tochon-Danguy, H.J.; Sachinidis, J.I.; Chan, J.G.; Cook, M.

    1997-01-01

    Positron Emission Tomography (PET) is a technique that utilizes positron-emitting radiopharmaceuticals to map the physiology, biochemistry and pharmacology of the human body. Positron-emitting radioisotopes produced in a medical cyclotron are incorporated into compounds that are biologically active in the body. A scanner measures radioactivity emitted from a patient's body and provides cross-sectional images of the distribution of these radiolabelled compounds in the body. It is the purpose of this paper to review the variety of PET radiopharmaceuticals currently produced at the Austin and Repatriation Medical Centre in Melbourne. Radioisotope production, radiolabelling of molecules and quality control of radiopharmaceuticals will be discussed. A few examples of their clinical applications will be shown as well. During the last five years we achieved a reliable routine production of various radiopharmaceuticals labelled with the four most important positron-emitters: oxygen-15 (t, 1/2 =2min), nitrogen-13 (t 1/2 = 10 min), carbon-11 (t 1/2 =20 min) and fluorine-18 (t 1/2 = 110 min). These radiopharmaceuticals include [ 15 O]oxygen, [ 15 O]carbon monoxide, [ 15 O]carbon dioxide, [ 15 O]water, [ 13 N]ammonia, [ 11 C]flumazenil, [ 11 C]SCH23390, [ 18 F]fluoromisonidazole and [ 18 F]fluoro-deoxy-glucose ([ 18 F]FDG). In addition, since the half life of [ 18 F] is almost two hours, regional distribution can be done, and the Austin and Repatriation Medical Centre is currently supplying [ 18 F]FDG in routine to other hospitals. Future new radiopharmaceuticals development include a [ 18 F]thymidine analog to measure cell proliferation and a [ 11 C]pyrroloisoquinoline to visualize serotonergic neuron abnormalities. (authors)

  13. Simulation of a Positron Source for CEBAF

    International Nuclear Information System (INIS)

    S. Golge; A. Freyberger; C. Hyde-Wright

    2007-01-01

    A positron source for the 6 GeV (or the proposed 12 GeV upgrade) recirculating linacs at Jefferson Lab is presented. The proposed 100nA CW positron source has several unique characteristics; high incident beam power (100kW), 10 MeV incident electron beam energy, CW incident beam and CW production. Positron production with 10 MeV electrons has several advantages; the energy is below neutron threshold so the production target will not become activated during use and the absolute energy spread is bounded by the low incident energy. These advantages are offset by the large angular distribution of the outgoing positrons. Results of simulations of the positron production, capture, acceleration and injection into the recirculating linac are presented. Energy flow and thermal management of the production target present a challenge and are included in the simulations

  14. Evaluation of Timepix silicon detector for the detection of 18F positrons

    Science.gov (United States)

    Wang, Q.; Tous, J.; Liu, Z.; Ziegler, S.; Shi, K.

    2014-05-01

    Timepix is an evolving energy and position sensitive pixel detector. It consists of a silicon detector (sensitive layer 300 μm thick) bump-bonded to the Timepix readout chip developed by the Medipix2 collaboration. This study aims to test the feasibility of using the acquired energy and position signals from Timepix for positron imaging. The signals of the commonly used fluorine-18 PET (positron emission tomography) tracer [18F]FDG were measured using Timepix operated both in single particle counting (Medipix) and in time over threshold (TOT) modes. The spatial resolution (SR) was measured using the absorber edge method (AEM) and was calculated from the over-sampled line spread function. The track of a positron in the Timepix detector was characterized as a cluster and the energy weighted centroid of each cluster was considered as readout for the position of the positron incidence. The measurement results were compared with theoretical predictions using Monte-Carlo simulations. In addition, imaging of a tissue slice of a mouse heart was analysed with reference to standard phosphor plate imaging. Our results show that the SR was improved from 177.1±4.1 μm (centroid without energy weighting) to 155.5±3.1 μm μm (centroid with energy weighting). About 12% enhancement of SR was achieved with energy information in TOT mode. The sensitivity of Timepix was 0.35 cps/Bq based on the measurements. The measuring background and the ratio between detected positrons and gamma rays were also evaluated and were found to be consistent with theoretical predictions. A small enhancement of image quality was also achieved by applying energy information to the data of the measured tissue sample. Our results show that the inclusion of energy information could slightly enhance the positron measurement compared to without energy information and the Timepix provides a high SR and sensitivity for positron detection. Thus, Timepix is a potentially effective tool for 2D positron imaging.

  15. Antimicrobial and cell-penetrating properties of penetratin analogs

    DEFF Research Database (Denmark)

    Bahnsen, Jesper Søborg; Franzyk, Henrik; Sandberg-Schaal, Anne

    2013-01-01

    Cell-penetrating peptides (CPPs) and antimicrobial peptides (AMPs) show great potential as drug delivery vectors and new antibiotic drug entities, respectively. The current study deals with the properties of a variety of peptide analogs derived from the well-known CPP penetratin as well as octaar......Cell-penetrating peptides (CPPs) and antimicrobial peptides (AMPs) show great potential as drug delivery vectors and new antibiotic drug entities, respectively. The current study deals with the properties of a variety of peptide analogs derived from the well-known CPP penetratin as well...... as octaarginine and different Tat sequences. The effects of peptide length, guanidinium content, and sequence of non-cationic residues were assessed in mammalian and bacterial cells. The arginine (Arg) content in the penetratin analogs was found to influence eukaryotic cell uptake efficiency, antimicrobial...... was similar, the eukaryotic cellular uptake of the shuffled analogs was noticeably lower than for native penetratin. Moreover, a point substitution of Met to Leu in native penetratin had no influence on eukaryotic cellular uptake and antimicrobial effect, and only a minor effect on cytotoxicity, in contrast...

  16. Intense positron beam and its application to surface science

    International Nuclear Information System (INIS)

    Ito, Y.; Hirose, M.; Kanazawa, I.; Sueoka, O.; Takamura, S.; Okada, S.

    1992-01-01

    Intense pulsed slow positron beam has been produced using the 100 MeV electron LINAC of JAERI · Tokai. In order to use the beam for surface studies such as positron diffraction and positron microscopy, it was transferred from the solenoid magnetic field to field free region and then was brightness-enhanced. The beam size was reduced from 10 mmφ (in the magnetic field) to 0.5 mmφ after two stages of re-moderation. Using the intense brightness-enhanced positron beam we have observed for the first time RHEPD (Reflection High-Energy Positron Diffraction) patterns. A design of re-emission positron microscopy is also described. (author)

  17. Study of a positron generation

    International Nuclear Information System (INIS)

    Nakahara, Kazuo; Enomoto, A.; Ikeda, M.; Ohsawa, S.; Kamitani, T.; Hosoyama, K.; Takei, H.; Emoto, T.; Tani, S.

    1998-03-01

    In the Power Reactor and Nuclear Fuel Development Corporation (PNC), the following are examined as part of an application technology using a high power electron linac: monochromatic gamma ray sources, free electron lasers, and intense positron sources. This report presents the study of an intense positron source, which has been developed jointly by High Energy Accelerator Research Organization (KEK) and PNC. In this report, we describe following items for an adaptive estimate of a superconducting magnet in order to efficiently converge a positron beam. (1) The cryostat which included the superconducting magnet is manufactured. (2) An excitement test of the superconducting magnet is carried out with a magnetic substance such as the electromagnet yoke. (author)

  18. The influence of positron trapping at vacancies on a pattern of the Fermi surface of #betta#-brass studied by positron annihilation

    International Nuclear Information System (INIS)

    Rozenfeld, B.; Chabik, S.; Pajak, J.

    1982-01-01

    Angular correlations of positron annihilation quanta (ACPAQ) have been measured for differently oriented monocrystalline samples of the ordered #betta#-brass under conditions permitting the neglecting of the trapping of positrons at vacancies as well as in the case when almost all the positrons annihilate being trapped at vacancies. It has been shown that trapping of positrons at vacancies can make the observation of the directional anisotropy in electron momentum distribution impossible. (Auth.)

  19. Single-quantum annihilation of positrons with shell-bound atomic electrons

    International Nuclear Information System (INIS)

    Palathingal, J.C.; Asoka-Kumar, P.; Lynn, K.G.; Posada, Y.; Wu, X.Y.

    1991-01-01

    The single-quantum annihilation of positrons has been studied experimentally with a positron beam and a thin lead target, at energies 1 MeV and higher. Spectral peaks corresponding to the K, L, and M shells have been resolved and observed distinctly for the first time. The shell ratios L/K and M/K have been determined. An analysis of the L peak has yielded the (LII+LIII)/L ratio. The first measurements of the directional distributions of the annihilation quanta of the three individual electron shells are also reported. The results are in agreement with theory. They also point out the potential for applying the phenomena to the development of a tunable, highly directional gamma-ray source

  20. Scattering data for modelling positron tracks in gaseous and liquid water

    International Nuclear Information System (INIS)

    Blanco, F; Roldán, A M; Krupa, K; García, G; McEachran, R P; Machacek, J R; Buckman, S J; Sullivan, J P; White, R D; Marjanović, S; Petrović, Z Lj; Brunger, M J; Chiari, L; Limão-Vieira, P

    2016-01-01

    We present in this study a self-consistent set of scattering cross sections for positron collisions with water molecules, in the energy range 0.1–10 000 eV, with the prime motivation being to provide data for modelling purposes. The structure of the database is based on a new model potential calculation, including interference terms, which provides differential and integral elastic as well as integral inelastic positron scattering cross sections for water molecules over the whole energy range considered here. Experimental and theoretical data available in the literature have been integrated into the database after a careful analysis of their uncertainties and their self-consistency. These data have been used as input parameters for a step-by-step Monte Carlo simulation procedure, providing valuable information on energy deposition, positron range, and the relative percentages of specific interactions (e.g. positronium formation, direct ionisation, electronic, vibrational and rotational excitations) in gaseous and liquid water. (paper)

  1. Positron beam studies of transients in semiconductors

    International Nuclear Information System (INIS)

    Beling, C.D.; Ling, C.C.; Cheung, C.K.; Naik, P.S.; Zhang, J.D.; Fung, S.

    2006-01-01

    Vacancy-sensing positron deep level transient spectroscopy (PDLTS) is a positron beam-based technique that seeks to provide information on the electronic ionization levels of vacancy defects probed by the positron through the monitoring of thermal transients. The experimental discoveries leading to the concept of vacancy-sensing PDLTS are first reviewed. The major problem associated with this technique is discussed, namely the strong electric fields establish in the near surface region of the sample during the thermal transient which tend to sweep positrons into the contact with negligible defect trapping. New simulations are presented which suggest that under certain conditions a sufficient fraction of positrons may be trapped into ionizing defects rendering PDLTS technique workable. Some suggestions are made for techniques that might avoid the problematic electric field problem, such as optical-PDLTS where deep levels are populated using light and the use of high forward bias currents for trap filling

  2. Positron lifetime measurements on electron irradiated amorphous alloys

    International Nuclear Information System (INIS)

    Moser, P.; Hautojaervi, P.; Chamberod, A.; Yli-Kauppila, J.; Van Zurk, R.

    1981-08-01

    Great advance in understanding the nature of point defects in crystalline metals has been achieved by employing positron annihilation technique. Positrons detect vacancy-type defects and the lifetime value of trapped positrons gives information on the size of submicroscopic vacancy aglomerates and microvoids. In this paper it is shown that low-temperature electron irradiations can result in a considerable increase in the positron lifetimes in various amorphous alloys because of the formation of vacancy-like defects which, in addition of the pre-existing holes, are able to trap positrons. Studied amorphous alloys were Fe 80 B 20 , Pd 80 Si 20 , Cu 50 Ti 50 , and Fe 40 Ni 40 P 14 B 6 . Electron irradiations were performed with 3 MeV electrons at 20 K to doses around 10 19 e - /cm 2 . After annealing positron lifetime spectra were measured at 77 K

  3. Low energy positron beam system for the investigation of 2D and porous materials

    International Nuclear Information System (INIS)

    Chrysler, M D; Chirayath, V A; Mcdonald, A D; Gladen, R W; Fairchild, A J; Koymen, A R; Weiss, A H

    2017-01-01

    An advanced variable energy positron beam (∼2 eV to 20 keV) has been designed, tested and utilized for coincidence Doppler broadening (CDB) measurements at the University of Texas at Arlington (UTA). A high efficiency solidified rare gas (Neon) moderator was used for the generation of a slow positron beam. The gamma rays produced as a result of the annihilation of positrons with the sample electrons are measured using a high purity Germanium (HPGe) detector in coincidence with a NaI(Tl) detector. Modifications to the system, currently underway, permits simultaneous measurements utilizing Positron annihilation induced Auger Electron Spectroscopy (PAES) and CDB. The tendency of positrons to become trapped in an image potential well at the surface will allow the new system to be used in measurements of the chemical structure of surfaces, internal or external and interfaces. The system will utilize a time of flight (TOF) technique for electron energy measurements. A 3m flight path from the sample to a micro-channel plate (MCP) in the new system will give it superior energy resolution at higher electron energies as compared to previous TOF systems utilizing shorter flight paths. (paper)

  4. Polarized positron sources for the future linear colliders

    International Nuclear Information System (INIS)

    Chaikovska, I.

    2012-01-01

    This thesis introduces the polarized positron source as one of the key element of the future Linear Collider (LC). In this context, the different schemes of the polarized positron source are described highlighting the main issues in this technology. In particular, the main focus is on the Compton based positron source adopted by the CLIC as a preferred option for the future positron source upgrade. In this case, the circularly polarized high energy gamma rays resulting from Compton scattering are directed to a production target where an electromagnetic cascade gives rise to the production of positrons by e + -e - pair conversion. To increase the efficiency of the gamma ray production stage, a multiple collision point line integrated in energy recovery linac is proposed. The simulations of the positron production, capture and primary acceleration allow to estimate the positron production efficiency and provide a simple parametrization of the Compton based polarized positron source in the view of the future LC requirements. The storage ring based Compton source option, so-called Compton ring, is also described. The main constraint of this scheme is given by the beam dynamics resulting in the large energy spread and increased bunch length affecting the gamma ray production rate. An original theoretical contribution is shown to calculate the energy spread induced by Compton scattering. Moreover, an experiment to test the gamma ray production by Compton scattering using a state-of-art laser system developed at LAL has been conducted in the framework of the 'Mighty Laser' project at the ATF, KEK. The experimental layout as well as the main results obtained are discussed in details. The studies carried out in this thesis show that the polarized positron source based on Compton scattering is a promising candidate for the future LC polarized positron source. (author)

  5. Simulation of ionization effects for high-density positron drivers in future plasma wakefield experiments

    International Nuclear Information System (INIS)

    Bruhwiler, D.L.; Dimitrov, D.A.; Cary, J.R.; Esarey, E.; Leemans, W.P.

    2003-01-01

    The plasma wakefield accelerator (PWFA) concept has been proposed as a potential energy doubler for present or future electron-positron colliders. Recent particle-in-cell (PIC) simulations have shown that the self-fields of the required electron beam driver can tunnel ionize neutral Li, leading to plasma wake dynamics differing significantly from that of a preionized plasma. It has also been shown, for the case of a preionized plasma, that the plasma wake of a positron driver differs strongly from that of an electron driver. We will present new PIC simulations, using the OOPIC code, showing the effects of tunneling ionization on the plasma wake generated by high-density positron drivers. The results will be compared to previous work on electron drivers with tunneling ionization and positron drivers without ionization. Parameters relevant to the energy doubler and the upcoming E-164x experiment at the Stanford Linear Accelerator Center will be considered

  6. Theory of the temperature dependence of positron bulk lifetimes-implications for vacancy formation enthalpy measurements via positron experiments

    International Nuclear Information System (INIS)

    Tam, S.W.; Sinha, S.K.; Siegel, R.W.

    1977-02-01

    Temperature dependent effects, which may have a bearing on determinations of vacancy formation enthalpies in metals by positron annihilation, have been observed in certain metals. These effects have been observed to occur both at temperatures below those at which positron annihilation is most sensitive to equilibrium vacancies and at temperatures well within the vacancy-sensitive region. The effect of thermal lattice displacements on positron lifetimes in metals was investigated to help understand these phenomena

  7. A hierarchical spatiotemporal analog forecasting model for count data.

    Science.gov (United States)

    McDermott, Patrick L; Wikle, Christopher K; Millspaugh, Joshua

    2018-01-01

    Analog forecasting is a mechanism-free nonlinear method that forecasts a system forward in time by examining how past states deemed similar to the current state moved forward. Previous applications of analog forecasting has been successful at producing robust forecasts for a variety of ecological and physical processes, but it has typically been presented in an empirical or heuristic procedure, rather than as a formal statistical model. The methodology presented here extends the model-based analog method of McDermott and Wikle (Environmetrics, 27, 2016, 70) by placing analog forecasting within a fully hierarchical statistical framework that can accommodate count observations. Using a Bayesian approach, the hierarchical analog model is able to quantify rigorously the uncertainty associated with forecasts. Forecasting waterfowl settling patterns in the northwestern United States and Canada is conducted by applying the hierarchical analog model to a breeding population survey dataset. Sea surface temperature (SST) in the Pacific Ocean is used to help identify potential analogs for the waterfowl settling patterns.

  8. Automatic activation of categorical and abstract analogical relations in analogical reasoning.

    Science.gov (United States)

    Green, Adam E; Fugelsang, Jonathan A; Dunbar, Kevin N

    2006-10-01

    We examined activation of concepts during analogical reasoning. Subjects made either analogical judgments or categorical judgments about four-word sets. After each four-word set, they named the ink color of a single word in a modified Stroop task. Words that referred to category relations were primed (as indicated by longer response times on Stroop color naming) subsequent to analogical judgments and categorical judgments. This finding suggests that activation of category concepts plays a fundamental role in analogical thinking. When colored words referred to analogical relations, priming occurred subsequent to analogical judgments, but not to categorical judgments, even though identical four-word stimuli were used for both types of judgments. This finding lends empirical support to the hypothesis that, when people comprehend the analogy between two items, they activate an abstract analogical relation that is distinct from the specific content items that compose the analogy.

  9. Porous silicon investigated by positron annihilation

    International Nuclear Information System (INIS)

    Cruz, R.M. de la; Pareja, R.

    1989-01-01

    The effect of the anodic conversion in silicon single crystals is investigated by positron lifetime measurements. Anodization at constant current induces changes in the positron lifetime spectrum of monocrystalline silicon samples. It is found that theses changes are primarily dependent on the silicon resistivity. The annihilation parameter behaviour of anodized samples, treated at high temperature under reducing conditions, is also investigated. The results reveal that positron annihilation can be a useful technique to characterize porous silicon formed by anodizing as well as to investigate its thermal behaviour. (author)

  10. New Developments in Positron Scintigraphy and the Application of Cyclotron-Produced Positron Emitters

    Energy Technology Data Exchange (ETDEWEB)

    Brownell, G. L.; Burnham, C. A.; Wilensky, S.; Aronow, S.; Kazemi, H.; Strieder, D. [Massachusetts General Hospital. Boston, MA (United States)

    1969-01-15

    The use of positron-emitting radioisotopes offers unique advantages inscintigraphy and dynamic function studies. The detection of the two annihilation quanta provides, in principle, the possibility of utilization of all the positron annihilations with good resolution. In practice, very high efficiencies can be achieved with large area annihilation quanta detectors. The use of multi-detector matrices as large area detectors permits high levels o f activity and yields very high data acquisition rates. The independence of attenuation with depth of a source offers marked advantages for quantitative measurement. The use of time-of-flight techniques opens the possibility of true three-dimensional visualization. Finally, a number of very short-lived positron emitting radioisotopes such as {sup 15}O, {sup 19}N and {sup 11}C are available. A hybrid positron scanner has been constructed and is undergoing tests for brain tumour localization using {sup 74}As. The scanner uses two rows of detectors each containing 9 Nal scintillators and phototubes. The detector array moves continuously in the horizontal direction and in steps in the vertical direction, producing a scintigram with no line structure. The data is recorded on tape for replay or for computer processing. In either case, the plane of best focus can be positioned at will. The techniques developed for the hybrid scanner will be used in a stationary device employing two two-dimensional arrays of detectors. The design will emphasize the very rapid collection of data and the sequential production of scintigrams. The advantages and techniques of positron annihilation detection are also applicable to devices for study of dynamic function. We have constructed and are testing a fast six-detector coincidence system for pulmonary function studies. The measurement of time-of-flight offers the possibility of three-dimensional visualization of a distribution of positron-emitting radioisotope. We a re studying systems with

  11. Techniques for slow positron beam generation and the applications

    International Nuclear Information System (INIS)

    Okada, Sohei

    1994-01-01

    Slow positron beams have been expected to be a powerful tool for observation of nature in wide range of research fields from materials science to basic physics, chemistry and biology. In this paper, at first, the beam technology is reviewed, which includes the positron generation, the transformation to slow positron beams and the beam manipulation such as beam stretching, bunching and brightness enhancement. Next, the present status of the slow positron beam applications to a variety of fields is demonstrated in terms of special characteristics of positron, that is, depth controllability, surface sensitivity, unique ionization channels and elemental anti-particle properties. Finally, prospects to produce intense slow positron beams are described. (author) 65 refs

  12. Positron emission tomography

    CERN Document Server

    Paans, A M J

    2006-01-01

    Positron Emission Tomography (PET) is a method for measuring biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides such as 11C, 13N, 15O and 18F and by measuring the annihilation radiation using a coincidence technique. This includes also the measurement of the pharmacokinetics of labelled drugs and the measurement of the effects of drugs on metabolism. Also deviations of normal metabolism can be measured and insight into biological processes responsible for diseases can be obtained. At present the combined PET/CT scanner is the most frequently used scanner for whole-body scanning in the field of oncology.

  13. Probing the defects in nano-semiconductors using positrons

    Energy Technology Data Exchange (ETDEWEB)

    Nambissan, P M G, E-mail: pmg.nambissan@saha.ac.in [Nuclear and Atomic Physics Division, Saha Institute of Nuclear Physics, 1/AF Bidhannagar, Kolkata 700064 (India)

    2011-01-10

    Positron annihilation spectroscopy (PAS) is a very useful tool to study the defect properties of nanoscale materials. The ability of thermalized positrons to diffuse over to the surfaces of nanocrystallites prior to annihilation helps to explore the disordered atomic arrangement over there and is very useful in understanding the structure and properties of nanomaterials. As examples, the results of studies on FeS{sub 2} nanorods and ZnS nanoparticles are presented. In semiconductor nanoparticles, there are positron trapping sites within the grains also and these are characterised by using appropriate models on the measured positron lifetimes. We have observed vivid changes in the measured positron lifetimes and Doppler broadened gamma ray spectral lineshapes during structural transformations prompted by substitutional effects in Mn{sup 2+}-doped ZnS nanorods. Interestingly, the nanoparticles did not exhibit the transformation, implying the morphologies of the nanosystems playing a decisive role. Quantum confinement effect in CdS nanoparticles was another phenomenon that could be seen through positron annihilation experiments. Coincidence Doppler broadening measurements have been useful to identify the elemental environment around the vacancy clusters that trap positrons. Recent studies on nanocrystalline oxide and sulphide semiconductors are also discussed.

  14. Probing the defects in nano-semiconductors using positrons

    International Nuclear Information System (INIS)

    Nambissan, P M G

    2011-01-01

    Positron annihilation spectroscopy (PAS) is a very useful tool to study the defect properties of nanoscale materials. The ability of thermalized positrons to diffuse over to the surfaces of nanocrystallites prior to annihilation helps to explore the disordered atomic arrangement over there and is very useful in understanding the structure and properties of nanomaterials. As examples, the results of studies on FeS 2 nanorods and ZnS nanoparticles are presented. In semiconductor nanoparticles, there are positron trapping sites within the grains also and these are characterised by using appropriate models on the measured positron lifetimes. We have observed vivid changes in the measured positron lifetimes and Doppler broadened gamma ray spectral lineshapes during structural transformations prompted by substitutional effects in Mn 2+ -doped ZnS nanorods. Interestingly, the nanoparticles did not exhibit the transformation, implying the morphologies of the nanosystems playing a decisive role. Quantum confinement effect in CdS nanoparticles was another phenomenon that could be seen through positron annihilation experiments. Coincidence Doppler broadening measurements have been useful to identify the elemental environment around the vacancy clusters that trap positrons. Recent studies on nanocrystalline oxide and sulphide semiconductors are also discussed.

  15. Probing the defects in nano-semiconductors using positrons

    Science.gov (United States)

    Nambissan, P. M. G.

    2011-01-01

    Positron annihilation spectroscopy (PAS) is a very useful tool to study the defect properties of nanoscale materials. The ability of thermalized positrons to diffuse over to the surfaces of nanocrystallites prior to annihilation helps to explore the disordered atomic arrangement over there and is very useful in understanding the structure and properties of nanomaterials. As examples, the results of studies on FeS2 nanorods and ZnS nanoparticles are presented. In semiconductor nanoparticles, there are positron trapping sites within the grains also and these are characterised by using appropriate models on the measured positron lifetimes. We have observed vivid changes in the measured positron lifetimes and Doppler broadened gamma ray spectral lineshapes during structural transformations prompted by substitutional effects in Mn2+-doped ZnS nanorods. Interestingly, the nanoparticles did not exhibit the transformation, implying the morphologies of the nanosystems playing a decisive role. Quantum confinement effect in CdS nanoparticles was another phenomenon that could be seen through positron annihilation experiments. Coincidence Doppler broadening measurements have been useful to identify the elemental environment around the vacancy clusters that trap positrons. Recent studies on nanocrystalline oxide and sulphide semiconductors are also discussed.

  16. Clinical impact of Positron Emission Tomography (PET) on oncological patients and their potentially application context

    International Nuclear Information System (INIS)

    Alonso, O.

    2006-01-01

    (PET) Positron Emission Tomography is a technique of nuclear medicine that has ability of detecting cancer through mechanisms based on molecular alterations of neoplastic processes. This review describes the PET Oncology applications and discusses the potential application of this technology in the sanitary and national academic framework . The most widely used in Oncology plotter is an analogue of laglucosa labelled with fluo: 18F-2-fluoro-2-Deoxy-D-glucose (FDG). In this way, the PET detects tumour retention of FDG, due to the highest glycolytic of cancer cells. In addition, the PET allow the study of the entire body at the same exploratory and some teams are coupled to systems of axial tomography (PET-CT). By ET-FDG, it is possible to diagnose, staging and restaged the majority of cancers, with diagnostic accuracy close to 90 per cent higher than the values provided by the conventional imaging techniques such. It is also possible to know early response to cancer treatments and obtain relevant medical prognosis information. (author) [es

  17. Positron annihilation studies on high temperature superconductors

    International Nuclear Information System (INIS)

    Sundar, C.S.; Bharathi, A.

    1996-01-01

    A survey of the positron annihilation studies on high temperature superconductors (HTSC), with results drawn mainly from our work, is presented. These include results of the studies on the temperature dependence of positron lifetime across T c , which have been carried out in the whole gamut of oxide superconductors. These experimental results are discussed in conjunction with the results of theoretically calculated positron density distribution, and it is shown that the observed temperature dependence of lifetime is intimately linked to the probing of the Cu-O network by the positrons. Results on the investigation of oxygen defects, which play a crucial role in HTSC, are presented. The most significant contribution of positrons to HTSC relates to the investigation of Fermi surface and the results of these studies, drawn from literature, are indicated. Some of our recent results in other novel superconducting materials, viz., the fullerenes and borocarbides are also presented. (author). 69 refs., 15 figs

  18. Electron-positron correlations in an electron liquid

    International Nuclear Information System (INIS)

    Stachowiak, H.

    1980-01-01

    The importance of studying electron-positron interaction for the interpretation of angular correlation data obtained for metallic systems is emphasized. The most successful approaches to electron-positron correlations in jellium are presented. Those include the Bethe-Goldstone two-body equation proposed by Kahana, the charge-density-dielectric function approach connected with the names of Singwi, Sjolander, Stott and Bhattacharyya and the Sawada boson-generalized Tamm-Dancoff approach elaborated recently by Arponen and Pajanne. In conclusion, it is reported that one can consider that the behaviour of a positron at rest in jellium is relatively well understood, though the problem of the optimal choice of a two-body electron-positron phenomenological equation is still open. Also, the behaviour of a positron in a real metal is not well understood and so far, serious calculations in this field have been performed only on very simple models while realistic calculations of the ACPAQ curves tend to minimize the importance of the problems which remain to be solved. (K.B.)

  19. Development of positron emitting radionuclides for imaging with improved positron detectors

    International Nuclear Information System (INIS)

    Yano, Y.

    1976-10-01

    Recent advances in positron cameras and positron ring detectors for transverse section reconstruction have created renewed interest in positron emitting radionuclides. This paper reports on: generator-produced 82 Rb; cyclotron-produced 62 Zn; and reactor-produced 64 Cu. Investigation of the 82 Sr (25 d)-- 82 Rb (75 s) generator determined the elution characteristics for Bio-Rex 70, a weakly acidic carboxylic cation exchanger, using 2% NaCl as the eluent. The yield of 82 Rb and the breakthrough of 82 Sr were determined for newly prepared columns and for long term elution conditions. Spallation-produced 82 Sr was used to charge a compact 82 Rb generator to obtain multi-millicurie amounts of 82 Rb for myocardial imaging. Zinc accumulates in the islet cells of the pancreas and in the prostate. Zinc-62 was produced by protons on Cu foil and separated by column chromatography. Zinc-62 was administered as the amino acid chelates and as the ZnCl 2 to tumor and normal animals. Tissue distribution was determined for various times after intravenous injection. Pancreas-liver images of 62 Zn-histidine uptake were obtained in animals with the gamma camera and the liver uptake of /sup 99m/Tc sulfur colloid was computer subtracted to image the pancreas alone. The positron camera imaged uptake of 62 Zn-histidine in the prostate of a dog at 20 h. 64 Cu was chelated to asparagine, a requirement of leukemic cells, and administered to lymphoma mice. Uptake in tumor and various tissues was determined and compared with the uptake of 67 Ga citrate under the same conditions. 64 Cu-asparagine had better tumor-to-soft tissue ratios than 67 Ga-citrate

  20. Positron annihilation study of polyphenylene dendrimers

    International Nuclear Information System (INIS)

    Marek, T.; Suevegh, K.; Vertes, A.; Ernst, A.; Bauer, R.; Weil, T.; Wiesler, U.; Klapper, M.; Muellen, K.

    2003-01-01

    The free volume of a series of rigid polyphenylene dendrimers was studied by positron lifetime spectroscopy and the experimental data were compared with results from molecular dynamics calculations. Contrary to dendrimers containing flexible repeat units rigid polyphenylene dendrimers proved to contain large stable 'inner' voids of a distinct size between their dendritic branches. The size of the 'inner' cavities increases with the size of the dendrimer. Due to these voids, polyphenylene dendrimers are potentially attractive with respect to the selective incorporation of guest molecules

  1. Positron Spectroscopy of Hydrothermally Grown Actinide Oxides

    Science.gov (United States)

    2014-03-27

    actinide oxides . The work described here is an attempt to characterize the quality of crystals using positron annihilation spectroscopy (PALS). The...Upadhyaya, R. V. Muraleedharan, B. D. Sharma and K. G. Prasad, " Positron lifetime studies on thorium oxide powders," Philosohical Magazine A, vol. 45... crystals . A strong foundation for actinide PALS studies was laid, but further work is required to build a more effective system. Positron Spectroscopy

  2. Positron beam studies of solids and surfaces: A summary

    International Nuclear Information System (INIS)

    Coleman, P.G.

    2006-01-01

    A personal overview is given of the advances in positron beam studies of solids and surfaces presented at the 10th International Workshop on Positron Beams, held in Doha, Qatar, in March 2005. Solids studied include semiconductors, metals, alloys and insulators, as well as biophysical systems. Surface studies focussed on positron annihilation-induced Auger electron spectroscopy (PAES), but interesting applications of positron-surface interactions in fields as diverse as semiconductor technology and studies of the interstellar medium serve to illustrate once again the breadth of scientific endeavour covered by slow positron beam investigations

  3. Positron beam studies of solids and surfaces: A summary

    Science.gov (United States)

    Coleman, P. G.

    2006-02-01

    A personal overview is given of the advances in positron beam studies of solids and surfaces presented at the 10th International Workshop on Positron Beams, held in Doha, Qatar, in March 2005. Solids studied include semiconductors, metals, alloys and insulators, as well as biophysical systems. Surface studies focussed on positron annihilation-induced Auger electron spectroscopy (PAES), but interesting applications of positron-surface interactions in fields as diverse as semiconductor technology and studies of the interstellar medium serve to illustrate once again the breadth of scientific endeavour covered by slow positron beam investigations.

  4. Application of positron emission tomography in the heart

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This report discusses experimental and clinical applications of positron emission tomography to the heart, including measurements of blood flow to the myocardium and studies of metabolism and experimental injury. Most initial clinical studies have concentrated on ischemic heart disease, but the technique also has potential for investigation of cardiomyopathies, studying the neural control of the heart, and evaluating the effects of drugs on cardiac tissues

  5. Analog computing

    CERN Document Server

    Ulmann, Bernd

    2013-01-01

    This book is a comprehensive introduction to analog computing. As most textbooks about this powerful computing paradigm date back to the 1960s and 1970s, it fills a void and forges a bridge from the early days of analog computing to future applications. The idea of analog computing is not new. In fact, this computing paradigm is nearly forgotten, although it offers a path to both high-speed and low-power computing, which are in even more demand now than they were back in the heyday of electronic analog computers.

  6. Using Analogies in Teaching Physics: A Study on Latvian Teachers' Views and Experience

    Science.gov (United States)

    Jonane, Lolita

    2015-01-01

    The role of analogies as tools for teaching difficult science concepts has been widely discussed in science education. The application of analogies in the context of sustainable education involves richer potential. The purposeful use of appropriate analogies can facilitate analogical thinking and transfer skills, as well as develop abilities which…

  7. Positron annihilation spectroscopy using high-energy photons

    International Nuclear Information System (INIS)

    Butterling, Maik; Jungmann, Marco; Krause-Rehberg, Reinhard; Krille, Arnold; Anwand, Wolfgang; Brauer, Gerhard; Cowan, Thomas E.; Hartmann, Andreas; Kosev, Krasimir; Schwengner, Ronald; Wagner, Andreas

    2010-01-01

    The superconducting electron accelerator ELBE (Electron Linac with high Brilliance and low Emittance) at the Research Centre Dresden-Rossendorf (Germany) serves as a high-intensity bremsstrahlung photon-source delivering a pulsed beam (26 MHz) with very short bunches (<5 ps). The photons are being converted into positrons by means of pair production inside the target material thus forming an intense positron source. The accelerator machine pulse is used as time reference allowing positron lifetime spectroscopy. We performed positron annihilation spectroscopy by pair production in different sample materials and used coincidence techniques to reduce the background due to scattered photons significantly in order resulting in spectra of extraordinary high quality. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  8. Polymeric membrane studied using slow positron beam

    International Nuclear Information System (INIS)

    Hung, W.-S.; Lo, C.-H.; Cheng, M.-L.; Chen Hongmin; Liu Guang; Chakka, Lakshmi; Nanda, D.; Tung, K.-L.; Huang, S.-H.; Lee, Kueir-Rarn; Lai, J.-Y.; Sun Yiming; Yu Changcheng; Zhang Renwu; Jean, Y.C.

    2008-01-01

    A radioisotope slow positron beam has been built at the Chung Yuan Christian University in Taiwan for the research and development in membrane science and technology. Doppler broadening energy spectra and positron annihilation lifetime have been measured as a function of positron energy up to 30 keV in a polyamide membrane prepared by the interfacial polymerization between triethylenetetraamine (TETA) and trimesoyl chloride (TMC) on modified porous polyacrylonitrile (PAN) asymmetric membrane. The multilayer structures and free-volume depth profile for this asymmetric membrane system are obtained. Positron annihilation spectroscopy coupled with a slow beam could provide new information about size selectivity of transporting molecules and guidance for molecular designs in polymeric membranes

  9. A Magnetic Transport Middle Eastern Positron Beam

    International Nuclear Information System (INIS)

    Al-Qaradawi, I.Y.; Britton, D.T.; Rajaraman, R.; Abdulmalik, D.

    2008-01-01

    A magnetically guided slow positron beam is being constructed at Qatar University and is currently being optimised for regular operation. This is the first positron beam in the Middle East, as well as being the first Arabic positron beam. Novel features in the design include a purely magnetic in-line deflector, working in the solenoid guiding field, to eliminate un-moderated positrons and block the direct line of sight to the source. The impact of this all-magnetic transport on the Larmor radius and resultant beam characteristics are studied by SIMION simulations for both ideal and real life magnetic field variations. These results are discussed in light of the coupled effect arising from electrostatic beam extraction

  10. Characteristics of the positron annihilation process in the matter

    International Nuclear Information System (INIS)

    Dryzek, J.

    2000-01-01

    In this report the positrons annihilation spectroscopy, as a method for the matter study is described. The interaction of positrons of high as well as thermal energies are discussed and different models of mentioned interactions are presented. Special attention is paid for positrons interaction with crystal lattice and its defects. The influence of positron beams characteristics on measured values are also discussed

  11. Polarized positrons and electrons at the linear collider

    International Nuclear Information System (INIS)

    Moortgat-Pick, G.; Abe, T.; Alexander, G.; Ananthanarayan, B.; Babich, A.A.; Bharadwaj, V.; Barber, D.; Bartl, A.; Brachmann, A.; Chen, S.; Clarke, J.; Clendenin, J.E.; Dainton, J.; Desch, K.; Diehl, M.; Dobos, B.; Dorland, T.; Dreiner, H.K.; Eberl, H.; Ellis, J.

    2008-01-01

    The proposed International Linear Collider (ILC) is well-suited for discovering physics beyond the Standard Model and for precisely unraveling the structure of the underlying physics. The physics return can be maximized by the use of polarized beams. This report shows the paramount role of polarized beams and summarizes the benefits obtained from polarizing the positron beam, as well as the electron beam. The physics case for this option is illustrated explicitly by analyzing reference reactions in different physics scenarios. The results show that positron polarization, combined with the clean experimental environment provided by the linear collider, allows to improve strongly the potential of searches for new particles and the identification of their dynamics, which opens the road to resolve shortcomings of the Standard Model. The report also presents an overview of possible designs for polarizing both beams at the ILC, as well as for measuring their polarization

  12. Positron annihilation studies on high temperature superconductors

    International Nuclear Information System (INIS)

    Sundar, C.S.; Bharathi, A.

    1991-01-01

    The results of positron annihilation measurements as a function of temperature, across Tc, in a variety of high temperature superconductors such as Y-Ba-Cu-O (Y1237), Y-Ba-Cu-O (Y1248), Bi-Sr-Ca-Cu-O, Tl-Ba-Ca-Cu-O, Ba-K-Bi-O and Nd-Ce-Cu-O are presented. It is shown that the variation of annihilation parameters in the superconducting state is correlated with the diposition of the positron density distribution with respect to the superconducting CuO planes. An increase in positron lifetime is observed below Tc when the positrons probe the CuO planes whereas a decrease in lifetime is observed when the positron density overlaps predominantly with the apical oxygen atom. With this correlation, the different temperature variation of annihilation parameters, seen in the various high temperature superconductors, is understood in terms of a local charge transfer from the planar oxygen atom to the apical oxygen atom. The significance of these results in the context of various theoretical models of high temperature superconductivity is discussed. In addition, the application of positron annihilation spectroscopy to the study of oxygen defects in the Y-Ba-Cu-O, Bi-Sr-Ca-Cu-O and Nd-Ce-Cu-O is presented. (author). 53 refs., 17 figs., 2 tabs

  13. Polarization Study for NLC Positron Source Using EGS4

    Energy Technology Data Exchange (ETDEWEB)

    Liu, James C

    2000-09-20

    SLAC is exploring a polarized positron source to study new physics for the NLC project. The positron source envisioned in this paper consists of a polarized electron source, a 50-MeV electron accelerator, a thin target less-than-or-equal-to 0.2 radiation length for positron production, and a capture system for high-energy, small angular divergence positrons. The EGS4 code was used to study the yield, energy spectra, emission-angle distribution, and the mean polarization of the positrons emanating from W-Re and Ti targets hit by longitudinally polarized electron and photon beams. To account for polarization within the EGS4 code a method devised by Flottmann was used, which takes into account polarization transfer for pair production, bremsstrahlung, and Compton interactions. A mean polarization of 0.85 for positrons with energies greater than 25 MeV was obtained. Most of the high-energy positrons were emitted within a forward angle of 20 degrees. The yield of positrons above 25 MeV per incident photon was 0.034, which was about 70 times higher than that obtained with an electron beam.

  14. Electron/positron measurements obtained with the Mars Science Laboratory Radiation Assessment Detector on the surface of Mars

    Directory of Open Access Journals (Sweden)

    J. Köhler

    2016-01-01

    Full Text Available The Radiation Assessment Detector (RAD, on board the Mars Science Laboratory (MSL rover Curiosity, measures the energetic charged and neutral particles and the radiation dose rate on the surface of Mars. Although charged and neutral particle spectra have been investigated in detail, the electron and positron spectra have not been investigated yet. The reason for that is that they are difficult to separate from each other and because of the technical challenges involved in extracting energy spectra from the raw data. We use GEANT4 to model the behavior of the RAD instrument for electron/positron measurements. We compare Planetocosmics predictions for different atmospheric pressures and different modulation parameters Φ with the obtained RAD electron/positron measurements. We find that the RAD electron/positron measurements agree well with the spectra predicted by Planetocosmics. Both RAD measurements and Planetocosmics simulation show a dependence of the electron/positron fluxes on both atmospheric pressure and solar modulation potential.

  15. Electron/positron measurements obtained with the Mars Science Laboratory Radiation Assessment Detector on the surface of Mars

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, J.; Wimmer-Schweingruber, R.F.; Appel, J. [Kiel Univ. (Germany). Inst. of Experimental and Applied Physics; and others

    2016-04-01

    The Radiation Assessment Detector (RAD), on board the Mars Science Laboratory (MSL) rover Curiosity, measures the energetic charged and neutral particles and the radiation dose rate on the surface of Mars. Although charged and neutral particle spectra have been investigated in detail, the electron and positron spectra have not been investigated yet. The reason for that is that they are difficult to separate from each other and because of the technical challenges involved in extracting energy spectra from the raw data. We use GEANT4 to model the behavior of the RAD instrument for electron/positron measurements.We compare Planetocosmics predictions for different atmospheric pressures and different modulation parameters Φ with the obtained RAD electron/positron measurements.We find that the RAD electron/positron measurements agree well with the spectra predicted by Planetocosmics. Both RAD measurements and Planetocosmics simulation show a dependence of the electron/positron fluxes on both atmospheric pressure and solar modulation potential.

  16. Generation of an intense pulsed positron beam and its applications

    International Nuclear Information System (INIS)

    Suzuki, Ryoichi; Mikado, Tomohisa; Ohgaki, Hideaki; Chiwaki, Mitsukuni; Yamazaki, Tetsuo; Kobayashi, Yoshinori.

    1994-01-01

    A positron pulsing system for an intense positron beam generated by an electron linac has been developed at the Electrotechnical Laboratory. The pulsing system generates an intense pulsed positron beam of variable energy and variable pulse period. The pulsed positron beam is used as a non destructive probe for various materials researches. In this paper, we report the present status of the pulsed positron beam and its applications. (author)

  17. Matrix Isolation Spectroscopy Applied to Positron Moderatioin in Cryogenic Solids

    Science.gov (United States)

    2011-07-01

    Current Positron Applications • 2-γ decay exploited in Positron Emission Tomography (PET) scanners. • Positrons localize & annihilate preferentially at...Air Force  Eglin Air Force Base AFRL-RW-EG-TP-2011-024 Matrix Isolation Spectroscopy Applied to Positron Moderation in Cryogenic Solids Distribution... Spectroscopy Applied to Positron Moderation in Cryogenic Solids 5a. CONTRACT NUMBER 5b. GRANT NUMBER 62602F 5c. PROGRAM ELEMENT NUMBER 6

  18. Gamma-induced positron annihilation spectroscopy and application to radiation-damaged alloys

    International Nuclear Information System (INIS)

    Wells, D.P.; Hunt, A.W.; Tchelidze, L.; Kumar, J.; Smith, K.; Thompson, S.; Selim, F.; Williams, J.; Harmon, J.F.; Maloy, S.; Roy, A.

    2006-01-01

    .P. Wells, et al., Nucl. Instr. and Meth. B. 241 (2005) 262]. These gamma-ray photons are then either measured with a high-resolution germanium detector (PAES) or fast scintillators (PALS) and subsequently analyzed using standard positron data analysis methods. The high penetrability of few MeV photons allows one to study defects and characterize materials in thick samples up to hundreds of g/cm2 (approximately a meter in steel), a thickness that is completely inaccessible by any other non-destructive technique. We have demonstrated the proof-of-principle of these techniques to probe tensile strain in thick steel alloys and other metals, to measure positron lifetimes in bulk samples of lead, copper and aluminium with positron lifetime spectra that are free of the surface and source background lifetimes that complicate conventional positron lifetime measurements, and demonstrated the activation technique for damage studies of copper and single-crystal iron [F.A. Selim, D.P. Wells, et al., Nucl. Instr. and Meth. B 192 (2002) 197, F.A. Selim, D.P. Wells, et al., Nucl. Instru. Meth. A 495 (2002) 154, F.A. Selim, et al., J. Rad. Phys. Chem. 68 (2004) 427]. We have also demonstrated the potential application of these techniques to 3-D imaging of defect density in thick structural materials [F.A. Selim, D.P. Wells, et al., Nucl. Instr. and Meth. B 241 (2005) 253, A.W. Hunt, D.P. Wells, et al., Nucl. Instr. and Meth. B. 241 (2005) 262

  19. Advanced characterization of lithium battery materials with positrons

    International Nuclear Information System (INIS)

    Barbiellini, Bernardo; Kuriplach, Jan

    2017-01-01

    Cathode materials are crucial to improved battery performance, in part because there are not yet materials that can maintain high power and stable cycling with a capacity comparable to that of anode materials. Our parameter-free, gradient-corrected model for electron-positron correlations predicts that spectroscopies based on positron annihilation can be deployed to study the effect of lithium intercalation in the oxide matrix of the cathode. The positron characteristics in oxides can be reliably computed using methods based on first-principles. Thus, we can enable a fundamental characterization of lithium battery materials involving positron annihilation spectroscopy and first-principles calculations. The detailed information one can extract from positron experiments could be useful for understanding and optimizing both battery materials and bi-functional catalysts for oxygen reduction and evolution. (paper)

  20. Radiopharmaceuticals in positron emission tomography: Radioisotope productions and radiolabelling procedures at the Austin and Repatriation Medical Centre

    Energy Technology Data Exchange (ETDEWEB)

    Tochon-Danguy, H.J.; Sachinidis, J.I.; Chan, J.G.; Cook, M. [Austin and Repatriation Medical Centre, Melbourne, VIC (Australia). Centre for Positron Emission Tomography

    1997-10-01

    Positron Emission Tomography (PET) is a technique that utilizes positron-emitting radiopharmaceuticals to map the physiology, biochemistry and pharmacology of the human body. Positron-emitting radioisotopes produced in a medical cyclotron are incorporated into compounds that are biologically active in the body. A scanner measures radioactivity emitted from a patient`s body and provides cross-sectional images of the distribution of these radiolabelled compounds in the body. It is the purpose of this paper to review the variety of PET radiopharmaceuticals currently produced at the Austin and Repatriation Medical Centre in Melbourne. Radioisotope production, radiolabelling of molecules and quality control of radiopharmaceuticals will be discussed. A few examples of their clinical applications will be shown as well. During the last five years we achieved a reliable routine production of various radiopharmaceuticals labelled with the four most important positron-emitters: oxygen-15 (t,{sub 1/2}=2min), nitrogen-13 (t{sub 1/2}= 10 min), carbon-11 (t{sub 1/2}=20 min) and fluorine-18 (t{sub 1/2}= 110 min). These radiopharmaceuticals include [{sup 15}O]oxygen, [{sup 15}O]carbon monoxide, [{sup 15}O]carbon dioxide, [{sup 15}O]water, [{sup 13}N]ammonia, [{sup 11}C]flumazenil, [{sup 11}C]SCH23390, [{sup 18}F]fluoromisonidazole and [{sup 18}F]fluoro-deoxy-glucose ([{sup 18}F]FDG). In addition, since the half life of [{sup 18}F] is almost two hours, regional distribution can be done, and the Austin and Repatriation Medical Centre is currently supplying [{sup 18}F]FDG in routine to other hospitals. Future new radiopharmaceuticals development include a [{sup 18}F]thymidine analog to measure cell proliferation and a [{sup 11}C]pyrroloisoquinoline to visualize serotonergic neuron abnormalities. (authors) 23 refs., 2 tabs.

  1. An automated blood sampling system used in positron emission tomography

    International Nuclear Information System (INIS)

    Eriksson, L.; Bohm, C.; Kesselberg, M.

    1988-01-01

    Fast dynamic function studies with positron emission tomography (PET), has the potential to give accurate information of physiological functions of the brain. This capability can be realised if the positron camera system accurately quantitates the tracer uptake in the brain with sufficiently high efficiency and in sufficiently short time intervals. However, in addition, the tracer concentration in blood, as a function of time, must be accurately determined. This paper describes and evaluates an automated blood sampling system. Two different detector units are compared. The use of the automated blood sampling system is demonstrated in studies of cerebral blood flow, in studies of the blood-brain barrier transfer of amino acids and of the cerebral oxygen consumption. 5 refs.; 7 figs

  2. Defects in Czochralski-grown silicon crystals investigated by positron annihilation

    Energy Technology Data Exchange (ETDEWEB)

    Ikari, Atsushi; Kawakami, Kazuto; Haga, Hiroyo [Nippon Steel Corp., Sagamihara, Kanagawa (Japan). Electronics Research Labs.; Uedono, Akira; Wei, Long; Kawano, Takao; Tanigawa, Shoichiro

    1994-10-01

    Positron lifetime and Doppler broadening experiments were performed on Czochralski-grown silicon crystals. A monoenergetic positron beam was also used to measure the diffusion length of positrons in the wafer. From the measurements, it was observed that the value of diffusion length of positrons decreased at the region where microdefects were formed during the crystal growth process. It was also found that the line shape parameter S decreased and the lifetime of positrons increased at the region. These results can be attributed to the annihilation of positrons trapped by vacancy oxygen complexes which are formed in association with the microdefects. (author).

  3. Stress evaluation at the ILC positron source

    Energy Technology Data Exchange (ETDEWEB)

    Ushakov, Andriy; Moortgat-Pick, Gudrid [Universitaet Hamburg, II. Institut fuer Theoretische Physik, Luruper Chaussee 149, 22761 Hamburg (Germany); Riemann, Sabine; Dietrich, Felix [Deutsches Elektronen-Synchrotron (DESY), Standort Zeuthen, Platanenallee 6, 15738 Zeuthen (Germany); Aulenbacher, Kurt; Tyukin, Valery; Heil, Philipp [Johannes Gutenberg-Universitaet Mainz, Institut fuer Kernphysik, Johann-Joachim-Becher-Weg 45, 55128 Mainz (Germany)

    2016-07-01

    High luminosity is required at future Linear Colliders which is particularly challenging for all corresponding positron sources. At the International Linear Collider (ILC), polarized positrons are obtained from electron-positron pairs by converting high-energy photons produced by passing the high-energy main electron beam through a helical undulator. The conversion target undergoes cyclic stress with high peak values. To distribute the thermal load, the target is designed as wheel spinning in vacuum with 100 m/s. However, the cyclic stress over long time at high target temperatures could exceed the fatigue stress limit. In the talk, an overview of the ILC positron source is given. The prospects to study material parameters under conditions as expected at the ILC are discussed.

  4. Ionization and positron emission in giant quasiatoms

    International Nuclear Information System (INIS)

    Soff, G.; Reinhardt, J.; Reus, T. de; Wietschorke, K.H.; Schaefer, A.; Mueller, B.; Greiner, W.; Mueller, U.; Schlueter, P.

    1985-07-01

    Electron excitation processes in superheavy quasiatoms are treated within a relativistic framework. Theoretical results on K-hole production rates as well as delta-electron and positron spectra are compared with experimental data. It is demonstrated that the study of heavy ion collisions with nuclear time delay promises a signature for the spontaneous positron formation in overcritical systems. Corresponding experimental results are confronted with our theoretical hypothesis. Recent speculations on the origin of the observed peak structures in positron spectra are critically reviewed. Atomic excitations are also employed to obtain information on the course of a nuclear reaction. Using a semiclassical picture we calculate the emission of delta-electrons and positrons in deep-inelastic nuclear reactions. Furthermore some consequences of conversion processes in giant systems are investigated. (orig.)

  5. Anti-Plasmodium activity of ceramide analogs

    Directory of Open Access Journals (Sweden)

    Gatt Shimon

    2004-12-01

    Full Text Available Abstract Background Sphingolipids are key molecules regulating many essential functions in eukaryotic cells and ceramide plays a central role in sphingolipid metabolism. A sphingolipid metabolism occurs in the intraerythrocytic stages of Plasmodium falciparum and is associated with essential biological processes. It constitutes an attractive and potential target for the development of new antimalarial drugs. Methods The anti-Plasmodium activity of a series of ceramide analogs containing different linkages (amide, methylene or thiourea linkages between the fatty acid part of ceramide and the sphingoid core was investigated in culture and compared to the sphingolipid analog PPMP (d,1-threo-1-phenyl-2-palmitoylamino-3-morpholino-1-propanol. This analog is known to inhibit the parasite sphingomyelin synthase activity and block parasite development by preventing the formation of the tubovesicular network that extends from the parasitophorous vacuole to the red cell membrane and delivers essential extracellular nutrients to the parasite. Results Analogs containing methylene linkage showed a considerably higher anti-Plasmodium activity (IC50 in the low nanomolar range than PPMP and their counterparts with a natural amide linkage (IC50 in the micromolar range. The methylene analogs blocked irreversibly P. falciparum development leading to parasite eradication in contrast to PPMP whose effect is cytostatic. A high sensitivity of action towards the parasite was observed when compared to their effect on the human MRC-5 cell growth. The toxicity towards parasites did not correlate with the inhibition by methylene analogs of the parasite sphingomyelin synthase activity and the tubovesicular network formation, indicating that this enzyme is not their primary target. Conclusions It has been shown that ceramide analogs were potent inhibitors of P. falciparum growth in culture. Interestingly, the nature of the linkage between the fatty acid part and the

  6. Development of a Simple Positron Age-Momentum Setup

    Science.gov (United States)

    Sheffield, Thomas; Quarles, C. A.

    2009-04-01

    A positron age-momentum setup that uses NIM Bin electronic modules and a conventional multichannel analyzer (MCA) is described. The essential idea is to accumulate a Doppler broadened spectrum (sensitive to the annihilation electron momentum) using a high purity Germanium detector in coincidence with a BaF2 scintillation counter, which also serves as the stop signal in a conventional positron lifetime setup. The MCA that collects the Doppler spectrum is gated by a selected region of the lifetime spectrum. Thus we can obtain Doppler broadening spectra as a function of positron lifetime: an age-momentum spectrum. The apparatus has been used so far to investigate a ZnO sample where the size of different vacancy trapping sites may affect the positron lifetime and the Doppler broadening spectrum. We are also looking at polymer and rubber carbon-black composite samples where differences in the Doppler spectrum may arise from positron trapping or positronium formation in the samples. Correction for background and contribution from the positron source itself to the Doppler spectrum will be discussed.

  7. Positron scattering by molecules: implementation of the C-tilde-functional; Espalhamento de positrons por moleculas: implementacao do funcional-C-tilde

    Energy Technology Data Exchange (ETDEWEB)

    Silva Lino, Jorge Luiz da

    1995-12-31

    In this work, we present a formulation called the C-Functional to study collisions of low-energy positron by molecules. This formalism is based on the Schwinger Multichannel Method for positrons which although being a quite general method (it is applicable to polyatomic molecules and include polarization and multichannel coupling) is limited to the use of trial wavefunctions consisting only of square integrable basis functions (Gaussian Cartesian Function). In principle this is not a problem, considering that the Schwinger type of methods require a good description of the scattering wavefunction only in the region where the potential is non-zero. However, there exist some situations (long range potentials) where the SMC has consequences. The C-functional (CF) consists in writing the wavefunctions as a sum of a plane-wave plus a combination of trial functions (where the combination is variationally determined). The basic difference between the 2 cases (SMC and CF) is the presence in the CF amplitude of the First (FBA) and Second Born terms. Aiming the preservation of important features of the SMG, we have developed general codes (applicable to polyatomic targets) to evaluate these terms. To illustrate the CF method we show elastic cross sections ti He and H{sub 2}. (author) 36 refs., 46 figs., 19 tabs.

  8. Channeling crystals for positron production

    International Nuclear Information System (INIS)

    Decker, F.J.

    1991-05-01

    Particles traversing at small angles along a single crystal axis experience a collective scattering force of many crystal atoms. The enormous fields can trap the particles along an axis or plane, called channeling. High energy electrons are attracted by the positive nuclei and therefore produce strongly enhanced so called coherent bremsstrahlung and pair production. These effects could be used in a positron production target: A single tungsten crystal is oriented to the incident electron beam within 1 mrad. At 28 GeV/c the effective radiation length is with 0.9 mm about one quarter of the amorphous material. So the target length can be shorter, which yields a higher conversion coefficient and a lower emittance of the positron beam. This makes single crystals very interesting for positron production targets. 18 refs., 2 figs

  9. Positron spectroscopy for materials characterization

    International Nuclear Information System (INIS)

    Schultz, P.J.; Snead, C.L. Jr.

    1988-01-01

    One of the more active areas of research on materials involves the observation and characterization of defects. The discovery of positron localization in vacancy-type defects in solids in the 1960's initiated a vast number of experimental and theoretical investigations which continue to this day. Traditional positron annihilation spectroscopic techniques, including lifetime studies, angular correlation, and Doppler broadening of annihilation radiation, are still being applied to new problems in the bulk properties of simple metals and their alloys. In addition new techniques based on tunable sources of monoenergetic positron beams have, in the last 5 years, expanded the horizons to studies of surfaces, thin films, and interfaces. In the present paper we briefly review these experimental techniques, illustrating with some of the important accomplishments of the field. 40 refs., 19 figs

  10. Science Teachers' Analogical Reasoning

    Science.gov (United States)

    Mozzer, Nilmara Braga; Justi, Rosária

    2013-08-01

    Analogies can play a relevant role in students' learning. However, for the effective use of analogies, teachers should not only have a well-prepared repertoire of validated analogies, which could serve as bridges between the students' prior knowledge and the scientific knowledge they desire them to understand, but also know how to introduce analogies in their lessons. Both aspects have been discussed in the literature in the last few decades. However, almost nothing is known about how teachers draw their own analogies for instructional purposes or, in other words, about how they reason analogically when planning and conducting teaching. This is the focus of this paper. Six secondary teachers were individually interviewed; the aim was to characterize how they perform each of the analogical reasoning subprocesses, as well as to identify their views on analogies and their use in science teaching. The results were analyzed by considering elements of both theories about analogical reasoning: the structural mapping proposed by Gentner and the analogical mechanism described by Vosniadou. A comprehensive discussion of our results makes it evident that teachers' content knowledge on scientific topics and on analogies as well as their pedagogical content knowledge on the use of analogies influence all their analogical reasoning subprocesses. Our results also point to the need for improving teachers' knowledge about analogies and their ability to perform analogical reasoning.

  11. Thermalisation of high energy electrons and positrons in water vapour

    Science.gov (United States)

    Munoz, A.; Blanco, F.; Limao-Vieira, P.; Thorn, P. A.; Brunger, M. J.; Buckman, S. J.; Garcia, G.

    2008-07-01

    In this study we describe a method to simulate single electron tracks of electrons in molecular gases, particularly in water vapour, from relatively high energies, where Born (Inokuti 1971) approximation is supposed to be valid, down to thermal energies paying special attention to the low energy secondary electrons which are abundantly generated along the energy degradation procedure. Experimental electron scattering cross sections (Munoz et al. 2007) and energy loss spectra (Thorn et al. 2007) have been determined, where possible, to be used as input parameters of the simulating program. These experimental data have been complemented with optical potential calculation (Blanco and Garcia 2003) providing a complete set of interaction probability functions for each type of collision which could take place in the considered energy range: elastic, ionization, electronic excitation, vibrational and rotational excitation. From the simulated track structure (Munoz et al. 2005) information about energy deposition and radiation damage at the molecular level can be derived. A similar procedure is proposed to the study of single positron tracks in gases. Due to the lack of experimental data for positron interaction with molecules, especially for those related to energy loss and excitation cross sections, some distribution probability data have been derived from those of electron scattering by introducing positron characteristics as positroniun formation. Preliminary results for argon are presented discussing also the utility of the model to biomedical applications based on positron emitters.

  12. 50 years of positrons

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    This year marks the 50th anniversary of one of the major landmarks of modern physics - the discovery of the positron, the antimatter counterpart of the electron. This provided the first evidence for antimatter, and it was also unprecedented for the existence of a new particle to have been predicted by theory. The positron and the concepts behind it were to radically change our picture of Nature. It led to the rapid advancement or our understanding, culminating some fifteen years later with the formulation of quantum electrodynamics as we now know it. (orig./HSI).

  13. Positron annihilation in metallic glasses - a general survey

    International Nuclear Information System (INIS)

    Brauer, G.; Kajcsos, Zs.; Kemeny, T.

    1981-08-01

    This report presents a review of the literature on positron annihilation studies concerning metallic glasses. After some general information and overview on structural models of metallic glasses as well as a short description of the positron annihilation method itself are added. Conclusions regarding information on the structure of metallic glasses obtainable by positron annihilation are also given. (author)

  14. PREFACE: The International Workshop on Positron Studies of Defects 2014

    Science.gov (United States)

    Sugita, Kazuki; Shirai, Yasuharu

    2016-01-01

    The International Workshop on Positron Studies of Defects 2014 (PSD-14) was held in Kyoto, Japan from 14-19 September, 2014. The PSD Workshop brought together positron scientists interested in studying defects to an international platform for presenting and discussing recent results and achievements, including new experimental and theoretical methods in the field. The workshop topics can be characterized as follows: • Positron studies of defects in semiconductors and oxides • Positron studies of defects in metals • New experimental methods and equipment • Theoretical calculations and simulations of momentum distributions, positron lifetimes and other characteristics for defects • Positron studies of defects in combination with complementary methods • Positron beam studies of defects at surfaces, interfaces, in sub-surface regions and thin films • Nanostructures and amorphous materials

  15. Positron annihilation in germanium in thermal equilibrium at high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Moriya, Tsuyoshi; Komuro, Naoyuki; Tanigawa, Shoichiro [Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science; Kawano, Takao; Ikari, Atsushi

    1996-09-01

    Annihilation characteristics of positrons in Ge in thermal equilibrium at high temperature were studied using a monoenergetic positron beam. Precise measurements of Doppler broadening profiles of annihilation radiation were performed in the temperature range between 300 K and 1211 K. The line shape parameters of Doppler broadening profiles were found to be almost constant at 300-600 K. The changes in these parameters were observed to start above 600 K. This was attributed to both the decrease in the fraction of positrons annihilating with core electrons and the lowering of the crystal symmetry around the region detected by positron-electron pairs. This suggests that behaviors of positrons are dominated by some form of positron-lattice coupling in Ge at high temperatures. The temperature dependence of the diffusion length of positrons was also discussed. (author)

  16. A simulation study of a method to reduce positron annihilation spread distributions using a strong magnetic field in positron emission tomography

    International Nuclear Information System (INIS)

    Iida, H.; Kanno, I.; Miura, S.; Murakami, M.; Takahashi, V.; Kemura, K.

    1986-01-01

    The positron trajectories have been three-dimensionally simulated using a Monte-Carlo method under various strength of the magnetic field. More than 5 tesla of the field confined the positrons effectively, resulting in increase of the probability of the annihilation within a limited small region, hence the higher spatial resolution in positron emission tomography

  17. Formation of a high intensity low energy positron string

    Science.gov (United States)

    Donets, E. D.; Donets, E. E.; Syresin, E. M.; Itahashi, T.; Dubinov, A. E.

    2004-05-01

    The possibility of a high intensity low energy positron beam production is discussed. The proposed Positron String Trap (PST) is based on the principles and technology of the Electron String Ion Source (ESIS) developed in JINR during the last decade. A linear version of ESIS has been used successfully for the production of intense highly charged ion beams of various elements. Now the Tubular Electron String Ion Source (TESIS) concept is under study and this opens really new promising possibilities in physics and technology. In this report, we discuss the application of the tubular-type trap for the storage of positrons cooled to the cryogenic temperatures of 0.05 meV. It is intended that the positron flux at the energy of 1-5 eV, produced by the external source, is injected into the Tubular Positron Trap which has a similar construction as the TESIS. Then the low energy positrons are captured in the PST Penning trap and are cooled down because of their synchrotron radiation in the strong (5-10 T) applied magnetic field. It is expected that the proposed PST should permit storing and cooling to cryogenic temperature of up to 5×109 positrons. The accumulated cooled positrons can be used further for various physics applications, for example, antihydrogen production.

  18. Formation of a high intensity low energy positron string

    International Nuclear Information System (INIS)

    Donets, E.D.; Donets, E.E.; Syresin, E.M.; Itahashi, T.; Dubinov, A.E.

    2004-01-01

    The possibility of a high intensity low energy positron beam production is discussed. The proposed Positron String Trap (PST) is based on the principles and technology of the Electron String Ion Source (ESIS) developed in JINR during the last decade. A linear version of ESIS has been used successfully for the production of intense highly charged ion beams of various elements. Now the Tubular Electron String Ion Source (TESIS) concept is under study and this opens really new promising possibilities in physics and technology. In this report, we discuss the application of the tubular-type trap for the storage of positrons cooled to the cryogenic temperatures of 0.05 meV. It is intended that the positron flux at the energy of 1-5 eV, produced by the external source, is injected into the Tubular Positron Trap which has a similar construction as the TESIS. Then the low energy positrons are captured in the PST Penning trap and are cooled down because of their synchrotron radiation in the strong (5-10 T) applied magnetic field. It is expected that the proposed PST should permit storing and cooling to cryogenic temperature of up to 5x10 9 positrons. The accumulated cooled positrons can be used further for various physics applications, for example, antihydrogen production

  19. Microstructural probing of ferritic/martensitic steels using internal transmutation-based positron source

    Energy Technology Data Exchange (ETDEWEB)

    Krsjak, Vladimir, E-mail: vladimir.krsjak@psi.ch; Dai, Yong

    2015-10-15

    This paper presents the use of an internal {sup 44}Ti/{sup 44}Sc radioisotope source for a direct microstructural characterization of ferritic/martensitic (f/m) steels after irradiation in targets of spallation neutron sources. Gamma spectroscopy measurements show a production of ∼1MBq of {sup 44}Ti per 1 g of f/m steels irradiated at 1 dpa (displaced per atom) in the mixed proton–neutron spectrum at the Swiss spallation neutron source (SINQ). In the decay chain {sup 44}Ti → {sup 44}Sc → {sup 44}Ca, positrons are produced together with prompt gamma rays which enable the application of different positron annihilation spectroscopy (PAS) analyses, including lifetime and Doppler broadening spectroscopy. Due to the high production yield, long half-life and relatively high energy of positrons of {sup 44}Ti, this methodology opens up new potential for simple, effective and inexpensive characterization of radiation induced defects in f/m steels irradiated in a spallation target.

  20. Microstructural probing of ferritic/martensitic steels using internal transmutation-based positron source

    Science.gov (United States)

    Krsjak, Vladimir; Dai, Yong

    2015-10-01

    This paper presents the use of an internal 44Ti/44Sc radioisotope source for a direct microstructural characterization of ferritic/martensitic (f/m) steels after irradiation in targets of spallation neutron sources. Gamma spectroscopy measurements show a production of ∼1MBq of 44Ti per 1 g of f/m steels irradiated at 1 dpa (displaced per atom) in the mixed proton-neutron spectrum at the Swiss spallation neutron source (SINQ). In the decay chain 44Ti → 44Sc → 44Ca, positrons are produced together with prompt gamma rays which enable the application of different positron annihilation spectroscopy (PAS) analyses, including lifetime and Doppler broadening spectroscopy. Due to the high production yield, long half-life and relatively high energy of positrons of 44Ti, this methodology opens up new potential for simple, effective and inexpensive characterization of radiation induced defects in f/m steels irradiated in a spallation target.

  1. Ice and Atoms: experiments with laboratory-based positron beams

    International Nuclear Information System (INIS)

    Coleman, P G

    2011-01-01

    This short review presents results of new positron and positronium (Ps) experiments in condensed matter and atomic physics, as an illustration of the satisfying variety of scientific endeavours involving positron beams which can be pursued with relatively simple apparatus in a university laboratory environment. The first of these two studies - on ice films - is an example of how positrons and Ps can provide new insights into an important system which has been widely interrogated by other techniques. The second is an example of how simple positron beam systems can still provide interesting information - here on a current interesting fundamental problem in positron atomic physics.

  2. Positron annihilation studies on nasicon analogues containing cation vacancies

    International Nuclear Information System (INIS)

    Sreeramalu, V.; Sreepad, H.R.; Chandrashekara, A.; Ravindrachary, V.; Gopal, S.

    1990-01-01

    Positron annihilation studies were carried out on the Nasicon analogue Na 2 (La, Al)Zr(PO 4 ) 3 compound for three different concentrations (2.2, 2.8 and 5.2 by wt.%) of ZrO 2 in the nutrient. Angular correlation study of annihilated photons reveals that the defect concentration is maximum for 2.8(wt.%) of ZrO 2 . Further, positron lifetime studies indicate that the positrons are trapped at cation vacancies. Application of a two state trapping model to this system made it possible to evaluate the lifetime of positrons in the Bloch state and of positrons trapped at cation vacancies. (author). 16 refs., 4 figs

  3. Electron-positron pair creation in heavy ion collisions

    International Nuclear Information System (INIS)

    Kienle, P.

    1987-08-01

    We review here the status of experiments to study the electron positron pair creation in heavy ion atom collisions at bombarding energies close to the Coulomb barrier. The disentanglement and characterisation of various sources of positrons observed in such collisions are described with a focus on the monoenergetic electron positron pairs observed. They seem to originate from the two-body decay of a family of neutral particles with masses of about 3 m e and life times in the range of 6x10 -14 s -10 s, produced by high Coulomb fields. First attempts were made to create these particles by resonant Bhabha scattering. First we present some experimental methods for high efficiency positron spectroscopy in heavy ion collisions. Then we describe the discovery of positron creation induced by strong time changing Coulomb fields. (orig./HSI)

  4. Experimental Observation of a Current-Driven Instability in a Neutral Electron-Positron Beam

    Science.gov (United States)

    Warwick, J.; Dzelzainis, T.; Dieckmann, M. E.; Schumaker, W.; Doria, D.; Romagnani, L.; Poder, K.; Cole, J. M.; Alejo, A.; Yeung, M.; Krushelnick, K.; Mangles, S. P. D.; Najmudin, Z.; Reville, B.; Samarin, G. M.; Symes, D. D.; Thomas, A. G. R.; Borghesi, M.; Sarri, G.

    2017-11-01

    We report on the first experimental observation of a current-driven instability developing in a quasineutral matter-antimatter beam. Strong magnetic fields (≥1 T ) are measured, via means of a proton radiography technique, after the propagation of a neutral electron-positron beam through a background electron-ion plasma. The experimentally determined equipartition parameter of ɛB≈10-3 is typical of values inferred from models of astrophysical gamma-ray bursts, in which the relativistic flows are also expected to be pair dominated. The data, supported by particle-in-cell simulations and simple analytical estimates, indicate that these magnetic fields persist in the background plasma for thousands of inverse plasma frequencies. The existence of such long-lived magnetic fields can be related to analog astrophysical systems, such as those prevalent in lepton-dominated jets.

  5. Elucidating the neurotoxic effects of MDMA and its analogs.

    Science.gov (United States)

    Karuppagounder, Senthilkumar S; Bhattacharya, Dwipayan; Ahuja, Manuj; Suppiramaniam, Vishnu; Deruiter, Jack; Clark, Randall; Dhanasekaran, Muralikrishnan

    2014-04-17

    There is a rapid increase in the use of methylenedioxymethamphetamine (MDMA) and its structural congeners/analogs globally. MDMA and MDMA-analogs have been synthesized illegally in furtive dwellings and are abused due to its addictive potential. Furthermore, MDMA and MDMA-analogs have shown to have induced several adverse effects. Hence, understanding the mechanisms mediating this neurotoxic insult of MDMA-analogs is of immense importance for the public health in the world. We synthesized and investigated the neurotoxic effects of MDMA and its analogs [4-methylenedioxyamphetamine (MDA), 2, 6-methylenedioxyamphetamine (MDMA), and N-ethyl-3, 4-methylenedioxyamphetamine (MDEA)]. The stimulatory or the dopaminergic agonist effects of MDMA and MDMA-analogs were elucidated using the established 6-hydroxydopamine lesioned animal model. Additionally, we also investigated the neurotoxic mechanisms of MDMA and MDMA-analogs on mitochondrial complex-I activity and reactive oxygen species generation. MDMA and MDMA-analogs exhibited stimulatory activity as compared to amphetamines and also induced several behavioral changes in the rodents. MDMA and MDMA-analogs enhanced the reactive oxygen generation and inhibited mitochondrial complex-I activity which can lead to neurodegeneration. Hence the mechanism of neurotoxicity, MDMA and MDMA-analogs can enhance the release of monoamines, alter the monoaminergic neurotransmission, and augment oxidative stress and mitochondrial abnormalities leading to neurotoxicity. Thus, our study will help in developing effective pharmacological and therapeutic approaches for the treatment of MDMA and MDMA-analog abuse. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Selective termination, fetal reduction and analogical reasoning.

    Science.gov (United States)

    Pennings, G

    2013-06-01

    Analogical reasoning is a basic method in bioethics. Its main purpose is to transfer the rule from an existing or known situation to a new and problematic situation. This commentary applies the lifeboat analogy to the context of selective termination and fetal reduction. It turns out that the analogy is only partially helpful as the main principle in the case of selective termination is the procreative beneficence principle. However, the wide person-affecting form of this principle doubly justifies selective termination: i.e. one prevents the harm caused by the birth of an affected child and one increases the life chances of the remaining fetuses. I conclude, however, that all analogies are basically flawed since they assume that fetuses as such have interests. I argue that fetuses only have interests to the extent that they are potential future persons. Copyright © 2013 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  7. Origin and annihilation physics of positrons in the Galaxy

    International Nuclear Information System (INIS)

    Alexis, Anthony

    2014-01-01

    A gamma radiation at 511 keV is observed since the early 1970's toward the Galactic bulge region. This emission is the signature of a large number of electron-positron annihilations, the positron being the electron's antiparticle. Unfortunately, the origin of the positrons responsible for this emission is still a mystery. Many positron-source candidates have been suggested but none of them can account for the galactic annihilation emission. The spatial distribution of this emission is indeed very atypical. Since 2002, the SPI spectrometer onboard the INTEGRAL space laboratory revealed an emission strongly concentrated toward the galactic bulge and a weaker emission from the galactic disk. This morphology is unusual because it does not correspond to any of the known galactic astrophysical-object or interstellar-matter distributions. The assumption that positrons annihilate close to their sources (i.e. the spatial distribution of the annihilation emission reflects the spatial distribution of the sources) has consequently been called into question. Recent studies suggest that positrons could propagate far away from their sources before annihilating. This physical aspect could be the key point to solve the riddle of the galactic positron origin. This thesis is devoted to the modelling of the propagation and annihilation of positrons in the Galaxy, in order to compare simulated spatial models of the annihilation emission with recent measurements provided by SPI/INTEGRAL. This method allows to put constraints on the origin of galactic positrons. We therefore developed a propagation Monte-Carlo code of positrons within the Galaxy in which we implemented all the theoretical and observational knowledge about positron physics (sources, transport modes, energy losses, annihilation modes) and the interstellar medium of our Galaxy (interstellar gas distributions, galactic magnetic fields, structures of the gaseous phases). Due to uncertainties in several physical parameters

  8. Positron radiography of ignition-relevant ICF capsules

    Science.gov (United States)

    Williams, G. J.; Chen, Hui; Field, J. E.; Landen, O. L.; Strozzi, D. J.

    2017-12-01

    Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 × 1012 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2 g/cm2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. We evaluate the effects of magnetic fields near the capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.

  9. Positron emitter labeled enzyme inhibitors

    International Nuclear Information System (INIS)

    Fowler, J.S.; MacGregor, R.R.; Wolf, A.P.; Langstrom, B.

    1990-01-01

    This invention involves a new strategy for imagining and mapping enzyme activity in the living human and animal body using positron emitter-labeled suicide enzyme inactivators or inhibitors which become covalently bound to the enzyme as a result of enzymatic catalysis. Two such suicide inactivators for monoamine oxidase have been labeled with carbon-11 and used to map the enzyme subtypes in the living human and animal body using PET. By using positron emission tomography to image the distribution of radioactivity produced by the body penetrating radiation emitted by carbon-11, a map of functionally active monoamine oxidase activity is obtained. Clorgyline and L-deprenyl are suicide enzyme inhibitors and irreversibly inhibit monoamine oxidase. When these inhibitors are labeled with carbon-11 they provide selective probes for monoamine oxidase localization and reactivity in vivo using positron emission tomography

  10. Instrumentation for positron emission tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Derenzo, S.E.; Huesman, R.H.

    1984-01-01

    Positron emission tomography with a spatial resolution of 2 mm full width at half maximum for quantitation in regions of interest 4 mm in diameter will become possible with the development of detectors that achieve ultrahigh resolution. Improved resolution will be possible using solid-state photodetectors for crystal identification or photomultiplier tubes with many small electron multipliers. Temporal resolution of 2 seconds and gating of cyclic events can be accomplished if statistical requirements are met. The major physical considerations in achieving high-resolution positron emission tomography are the degradation in resolution resulting from positron range, emission angle, parallax error, detector sampling density, the sensitivity of various detector materials and packing schemes, and the tradeoff between temporal resolution and statistical accuracy. The accuracy of data required for physiological models depends primarily on the fidelity of spatial sampling independent of statistical constraints

  11. Nanometer cavities studied by positron annihilation

    International Nuclear Information System (INIS)

    Mogensen, O.E.

    1992-01-01

    Positronium (Ps) is trapped in cavities in insulating solids, and the lifetime of ortho Ps is determined by the size of the cavity. The information on the properties of the cavities obtained by use of the standard slow positron beam and the 'normal' positron annihilation techniques is compared for several selected cases. (author)

  12. A new slow positron beam facility using a compact cyclotron

    International Nuclear Information System (INIS)

    Hirose, Masafumi

    1998-01-01

    In 1993, Sumitomo Heavy Industries became the first in the world to successfully produce a slow positron beam using a compact cyclotron. Slow positron beam production using an accelerator had mainly consisted of using an electron linear accelerator (LINAC). However, the newly developed system that uses a compact cyclotron enabled cost reduction, downsizing of equipment, production of a DC slow positron beam, a polarized slow positron beam, and other benefits. After that, a genuine slow positron beam facility was developed with the construction of compact cyclotron No.2, and beam production in the new facility has already been started. The features of this new slow positron beam facility are explained below. 1) It is the world's first compact slow positron beam facility using a compact cyclotron. 2) It is the only genuine slow positron beam facility in the world which incorporates the production and use of a slow positron beam in the design stage of the cyclotron. To use a slow positron beam for non-destructive detection of lattice defects in semiconductor material, it is necessary to convert the beam into ultra-short pulses of several hundreds of pico-seconds. Sumitomo Heavy Industries has devised a new short-pulsing method (i.e. an induction bunching method) that enables the conversion of a slow positron beam into short pulses with an optimum pulsing electric field change, and succeeded in converting a slow positron beam into short pulses using this method for the first time in the world. Non-destructive detection of lattice defects in semiconductor material using this equipment has already been started, and some information about the depth distribution, size, density, etc. of lattice defects has already been obtained. (J.P.N.)

  13. Plasma Wakefield Acceleration of an Intense Positron Beam

    Energy Technology Data Exchange (ETDEWEB)

    Blue, B

    2004-04-21

    The Plasma Wakefield Accelerator (PWFA) is an advanced accelerator concept which possess a high acceleration gradient and a long interaction length for accelerating both electrons and positrons. Although electron beam-plasma interactions have been extensively studied in connection with the PWFA, very little work has been done with respect to positron beam-plasma interactions. This dissertation addresses three issues relating to a positron beam driven plasma wakefield accelerator. These issues are (a) the suitability of employing a positron drive bunch to excite a wake; (b) the transverse stability of the drive bunch; and (c) the acceleration of positrons by the plasma wake that is driven by a positron bunch. These three issues are explored first through computer simulations and then through experiments. First, a theory is developed on the impulse response of plasma to a short drive beam which is valid for small perturbations to the plasma density. This is followed up with several particle-in-cell (PIC) simulations which study the experimental parameter (bunch length, charge, radius, and plasma density) range. Next, the experimental setup is described with an emphasis on the equipment used to measure the longitudinal energy variations of the positron beam. Then, the transverse dynamics of a positron beam in a plasma are described. Special attention is given to the way focusing, defocusing, and a tilted beam would appear to be energy variations as viewed on our diagnostics. Finally, the energy dynamics imparted on a 730 {micro}m long, 40 {micro}m radius, 28.5 GeV positron beam with 1.2 x 10{sup 10} particles in a 1.4 meter long 0-2 x 10{sup 14} e{sup -}/cm{sup 3} plasma is described. First the energy loss was measured as a function of plasma density and the measurements are compared to theory. Then, an energy gain of 79 {+-} 15 MeV is shown. This is the first demonstration of energy gain of a positron beam in a plasma and it is in good agreement with the predictions

  14. High efficiency cyclotron trap assisted positron moderator

    OpenAIRE

    Gerchow, L.; Cooke, D. A.; Braccini, S.; Döbeli, M.; Kirch, K.; Köster, U.; Müller, A.; Van Der Meulen, N. P.; Vermeulen, C.; Rubbia, A.; Crivelli, P.

    2017-01-01

    We report the realisation of a cyclotron trap assisted positron tungsten moderator for the conversion of positrons with a broad keV- few MeV energy spectrum to a mono-energetic eV beam with an efficiency of 1.8(2)% defined as the ratio of the slow positrons divided by the $\\beta^+$ activity of the radioactive source. This is an improvement of almost two orders of magnitude compared to the state of the art of tungsten moderators. The simulation validated with this measurement suggests that usi...

  15. Positron emission tomography. Positronemisionstomografi

    Energy Technology Data Exchange (ETDEWEB)

    Bolwig, T G; Haunsoe, S; Dahlgaard Hove, J; Hesse, B; Hoejgard, L; Jensen, M; Paulson, O B; Hastrup Svendsen, J; Soelvsten Soerensen, S

    1994-10-01

    Positron emission tomography (PET) is a method for quantitative imaging of regional physiological and biochemical parameters. Positron emitting radioactive isotopes can be produced by a cyclotron, eg. the biologically important carbon ([sup 11]C), oxygen ([sup 15]O), and nitrogen ([sup 13]N) elements. With the tomographic principles of the PET scanner the quantitative distribution of the administered isotopes can be determined and images can be provided as well as dynamic information on blood flow, metabolism and receptor function. In neurology PET has been used for investigations on numerous physiological processes in the brain: circulation, metabolism and receptor studies. In Parkinson's disease PET studies have been able to localize the pathology specifically, and in early stroke PET technique can outline focal areas with living but non-functioning cells, and this could make it possible to intervene in this early state. With positron emission tomography a quantitative evaluation of myocardial blood flow, glucose and fatty acid metabolism can be made as well as combined assessments of blood flow and metabolism. Combined studies of blood flow and metabolism can determine whether myocardial segments with abnormal motility consist of necrotic or viable tissue, thereby delineating effects of revascularisation. In the future it will probably be possible to characterize the myocardial receptor status in different cardiac diseases. The PET technique is used in oncology for clinical as well as more basic research on tumor perfusion and metabolism. Further, tumor uptake of positron labelled cytotoxic drugs might predict the clinical benefit of treatment. (au) (19 refs.).

  16. Study of radiation damage in metals by positron annihilation

    International Nuclear Information System (INIS)

    Gauster, W.B.

    1977-01-01

    Positron annihilation is a sensitive technique for probing defects in metals and it has recently been shown to be a valuable tool for the study of radiation damage. After an introduction to the three basic experimental methods (angular correlation, Doppler broadening, and lifetime measurements), the interaction of positrons with lattice defects is reviewed. Results for the annealing of damage after low temperature irradiation are used to show that positron annihilation has provided new information on annealing kinetics. The role of positron techniques in characterizing complex defect structures resulting from high-temperature neutron irradiation is reviewed and the possible utility of positron annihilation as a nondestructive monitor of property changes is pointed out

  17. Imaging optimizations with non-pure and high-energy positron emitters in small animal positron computed tomography

    International Nuclear Information System (INIS)

    Harzmann, Sophie

    2014-01-01

    The contribution on imaging optimizations with non-pure and high-energy positron emitters in small animal positron emission tomography (PET) covers the following topics: physical fundamentals of PET, mathematical image reconstruction and data analyses, Monte-Carlo simulations and implemented correction scheme, quantification of cascade gamma coincidences based on simulations and measurements, sinogram based corrections, restoration of the spatial resolution, implementation of full corrections.

  18. Application of position-sensitive detectors to positron imaging

    International Nuclear Information System (INIS)

    Yamashita, Takaji; Uchida, Hiroshi; Watanabe, Mitsuo; Omura, Tomohide

    1994-01-01

    Positron imaging including positron emission tomography (PET) is expected to be a promising tool for basic and clinical research, because it makes possible the study of regional chemistry within multiple organs of the body in living human beings and experimental animals. New schemes of high resolution block detectors have been developed to improve the performance of positron imaging systems, which employ small segments of bismuth germanate (BGO) arrays and position-sensitive photomultiplier tubes (PS-PMT). The coincidence detector resolution of less than 2.0 mm in full width at half maximum was achieved with the detectors, which is very close to the theoretical resolution limit in positron imaging. (author)

  19. Precision analog signal processor for beam position measurements in electron storage rings

    International Nuclear Information System (INIS)

    Hinkson, J.A.; Unser, K.B.

    1995-05-01

    Beam position monitors (BPM) in electron and positron storage rings have evolved from simple systems composed of beam pickups, coaxial cables, multiplexing relays, and a single receiver (usually a analyzer) into very complex and costly systems of multiple receivers and processors. The older may have taken minutes to measure the circulating beam closed orbit. Today instrumentation designers are required to provide high-speed measurements of the beam orbit, often at the ring revolution frequency. In addition the instruments must have very high accuracy and resolution. A BPM has been developed for the Advanced Light Source (ALS) in Berkeley which features high resolution and relatively low cost. The instrument has a single purpose; to measure position of a stable stored beam. Because the pickup signals are multiplexed into a single receiver, and due to its narrow bandwidth, the receiver is not intended for single-turn studies. The receiver delivers normalized measurements of X and Y position entirely by analog means at nominally 1 V/mm. No computers are involved. No software is required. Bergoz, a French company specializing in precision beam instrumentation, integrated the ALS design m their new BPM analog signal processor module. Performance comparisons were made on the ALS. In this paper we report on the architecture and performance of the ALS prototype BPM

  20. The MEG positron spectrometer

    International Nuclear Information System (INIS)

    Nishiguchi, Hajime

    2007-01-01

    We have been developing an innovative spectrometer for the MEG experiment at the Paul Scherrer Institute (PSI) in Switzerland. This experiment searches for a lepton flavour violating decay μ + →e + γ with a sensitivity of 10 -13 in order to explore the region predicted by supersymmetric extensions of the standard model. The MEG positron spectrometer consists of a specially designed superconducting solenoidal magnet with a highly graded field, an ultimate low-mass drift chamber system, and a precise time measuring counter system. This innovative positron spectrometer is described here focusing on the drift chamber system

  1. Depth profiling of boron implanted silicon by positron beam

    International Nuclear Information System (INIS)

    Oevuenc, S.

    2004-01-01

    Positron depth profiling analyses of low energy implants of silicon aim to observe tbe structure and density of the vacancies generating by implantation and the effect of annealing. This work present the results to several set of data starting S and W parameters. Boron implanted Silicon samples with different implantation energies,20,22,24,and 26 keV are analyzed by Slow positron beam (0-40 keV and 10 5 e + /s )(Variable Energy Positron) at the Positron Centre Delf-HOLLAND

  2. Pattern evoked cortical potential topography and positron emission computed tomography in cases with homonymous quadrantanopsia

    International Nuclear Information System (INIS)

    Kakisu, Yonetsugu; Adachi-Usami, Emiko; Kuroda, Noriko; Kawamura, Mitsuru; Yamazaki, Toshiro.

    1985-01-01

    Pattern evoked cortical potentials (PVECPs) and positron emission computed tomography (PET) were studied in two cases with lower homonymous quadrantanopsia caused by occlusion or hemorrhages of the artery of the optic radiation. Using 15 O 2 and C 15 O 2 as a tracer, PET was performed at rest under opened eye stimulation on 6 cm and 8 cm transverse section above the orbito-meatal line. On OM-6 level where the visual cortex of right and left hemisphere received the upper visual field information, symmetrical images of 15 O 2 and C 15 O 2 uptake were found. However, they were lateralized at the non-affected hemisphere in the images of OM-8 level, which corresponded to the anatomical lesion. The PVECP topogram recorded to the stimulation of the right and left lower quadrant visual field was studied by a 16 channel recording system. The positive maxima at the peak latency of P100 were found only at the non-affected hemisphere. It was, thus, proved that PVECP topogram and PET findings could demonstrate the functional abnormalities of the visual cortex in accordance with visual field defect measured by subjective perimetry. (author)

  3. Diagnostic merits of current and potential applications of single photon and positron imaging: a perspective

    International Nuclear Information System (INIS)

    Harper, P.V.

    1978-01-01

    A brief review of the limitations of medical radionuclide imaging techniques in competition with x-ray CAT scanning and ultrasound suggest that the emphasis in this are should be on measurement of the physiologic uptake of tracer materials. Tomography greatly improves the possibilities of quantitation of this uptake - examples using positron and single photon techniques are presented for 13 NH 3 and 201 Tl in the heart

  4. Positron annihilation spectroscopic studies of 6H silicon carbide

    International Nuclear Information System (INIS)

    Hu, Y.F.; Lam, C.H.; Ling, C.C.; Fung, S.; Beling, C.D.; Weng, H.M.

    2001-01-01

    Positron lifetime measurements have been performed on p-type and n-type 6H-SiC with temperatures varying from 10 K to 290 K. The V C V Si divacancy is observed in both types of 6H-SiC where the V Si related defect is only found in the n-type material. Positron trapping into a defect with lifetime value close to the bulk was found to compete with positron trapping into V Si or V C V Si at temperatures lower than 80 K. The positron diffusion length of the 1400 C annealed n-type 6H-SiC has also been measured at different temperatures with the use of a positron beam. Positron diffusion was found to be limited by acoustic phonon scattering at T=150-300 K. However, at T=50-150 K, D + follows T 2.12±0.02 and the details of the physical process is not yet known. (orig.)

  5. The effects of low-energy scattering on positron implantation

    Energy Technology Data Exchange (ETDEWEB)

    Ritley, K.A. (Dept. of Physics and Materials Research Laboratory, Univ. of Illinois, Urbana, IL (United States)); Lynn, K.G.; Ghosh, V.; Welch, D.O. (Brookhaven National Lab., Upton, NY (United States))

    1992-01-01

    Existing Monte Carlo models are capable of simulating the behavior of positrons incident at keV energies, then following the energy loss process to arbitrary final kinetic energies of from 20 eV to 100 eV. This work describes a Monte Carlo simulation of the final stages of positron thermalization in Al, from 25 eV to thermal energies, via the mechanisms of conduction-electron and longitudinal acoustic phonon scattering. The latter stages of thermalization can have important effects on the stopping profiles and mean depth. A novel way to obtain information about positron energy loss by considering the time-evolution of a point-concentration (delta-function distribution) of positrons is described. The effects of a positive positron work function are examined for the first time in the context of a positron Monte Carlo calculation. Finally, some issues relating to the agreement of Monte Carlo calculations with experimental data are discussed. 6 figs., 16 refs.

  6. The effects of low-energy scattering on positron implantation

    Energy Technology Data Exchange (ETDEWEB)

    Ritley, K.A. [Dept. of Physics and Materials Research Laboratory, Univ. of Illinois, Urbana, IL (United States); Lynn, K.G.; Ghosh, V.; Welch, D.O. [Brookhaven National Lab., Upton, NY (United States)

    1992-12-31

    Existing Monte Carlo models are capable of simulating the behavior of positrons incident at keV energies, then following the energy loss process to arbitrary final kinetic energies of from 20 eV to 100 eV. This work describes a Monte Carlo simulation of the final stages of positron thermalization in Al, from 25 eV to thermal energies, via the mechanisms of conduction-electron and longitudinal acoustic phonon scattering. The latter stages of thermalization can have important effects on the stopping profiles and mean depth. A novel way to obtain information about positron energy loss by considering the time-evolution of a point-concentration (delta-function distribution) of positrons is described. The effects of a positive positron work function are examined for the first time in the context of a positron Monte Carlo calculation. Finally, some issues relating to the agreement of Monte Carlo calculations with experimental data are discussed. 6 figs., 16 refs.

  7. Temperature dependence of positron trapping by vacancies, loops and voids in molybdenum

    International Nuclear Information System (INIS)

    Bentzon, M.D.; Linderoth, S.; Petersen, K.

    1985-01-01

    The temperature dependence of positron trapping by defects in molybdenum has been studied. By resolving positron lifetime spectra into three components, it has been possible to distinguish the temperature dependence of positron trapping into loops and voids. The results show that the positron trapping rate into voids depends linearly on temperature. The temperature dependence of positron trapping by loops can be interpreted as positrons being trapped by jogs, directly or via the dislocation line. The temperature dependence of positrons trapped by loops is argued mainly to be due to the trapping at the dislocation line, and not to detrapping. The observed temperature dependence of positron annihilation parameters in an electron irradiated sample (below stage III), is explained by competitive positron trapping in interstitial loops at low temperatures

  8. Temperature dependence of the fraction of re-emitted positrons, the positron work function, and the positronium fraction for Cu(III)+S

    International Nuclear Information System (INIS)

    Schultz, P.J.; Lynn, K.G.

    1982-01-01

    A beam of 1 keV positrons incident on a Cu(111)+S surface has been used to study the dependence on temperature of the positron work function (phi/sub +/), the yield of re-emitted positrons (Y) and of the positronium (Ps) fraction. A positive dependence of the slow-positron yield on temperature is found which is attributed in part to a reduction in the magnitude of phi/sub +/ (approx. 25%) at 50 K relative to its value at 300 K. A similar, though weaker, positive dependence on temperature was seen for the Ps fraction down to 40 K. We present a suggestion for the apparent lack of reflection

  9. Positron-trapping mechanism at dislocations in Zn

    DEFF Research Database (Denmark)

    Hidalgo, Carlos; Linderoth, Søren; Diego, Nieves de

    1987-01-01

    the average lifetime and the intensity of the long component decrease with increasing temperature. The experimental results are very well described in terms of a generalized trapping model where it is assumed that positrons become trapped in deep traps (jogs) via shallow traps (dislocation lines......). The temperature dependence of the positron-lifetime spectra below 120 K is attributed to the temperature dependence of the trapping rate to the dislocation line. The experimental results have demonstrated that detrapping processes from the dislocation line take place above 120 K. The positron binding energy...

  10. In-situ positron emission of CO oxidation

    OpenAIRE

    Vonkeman, K.A.; Jonkers, G.; Wal, van der, S.W.A.; Santen, van, R.A.

    1993-01-01

    Using a Neuro ECAT positron tomog., the Positron Emission computed Tomog. (PET) was utilized to image the catalytic oxidn. of CO by using CO and CO2, labeled with short lived positron emitting nuclides. Studies were performed over highly dispersed CeO2/g-Al2O3 supported Pt and Rh catalysts. With a math. model of the reaction kinetics, based on the elementary steps of the catalytic reaction and partially on literature surface science data, the effect of CeO2 promotion and the presence of NO we...

  11. Positron emission tomography studies of brain receptors

    International Nuclear Information System (INIS)

    Maziere, B.; Maziere, M.

    1991-01-01

    Probing the regional distribution and affinity of receptors in the brain, in vivo, in human and non human primates has become possible with the use of selective ligands labelled with positron emitting radionuclides and positron emission tomography (PET). After describing the techniques used in positron emission tomography to characterize a ligand receptor binding and discussing the choice of the label and the limitations and complexities of the in vivo approach, the results obtained in the PET studies of various neurotransmission systems: dopaminergic, opiate, benzodiazepine, serotonin and cholinergic systems are reviewed

  12. Positron-emitting raionuclides: present and future status

    International Nuclear Information System (INIS)

    Lambrecht, R.M.

    1979-01-01

    A tabulation of 157 positron-emitting radionuclides that have the physical characteristics deemed appropriate for radiopharmaceutical use in conjunction with positron emission tomography is provided. The most promising radionuclides are within the production capabilities of a variable-energy cyclotron accelerating protons to about 40 MeV and deuterons, helium-3, and helium-4 to compatable energies. To data only 27 positron-emitting radionuclides have been subjected to radiopharmaceutical consideration, whereas only 11 C, 13 N, 15 O, 18 F, 38 K, and 68 Ga have proved to be especially promising. 2 tables

  13. Positron reemission microscopy

    International Nuclear Information System (INIS)

    Brandes, G.F.; Canter, K.F.; Mills, A.P. Jr.

    1991-01-01

    The positron reemission microscope (PRM), originally proposed by Hulett, Dale and Pendyala, operates on principles fundamentally different from those utilized in existing microscopes and offers sensitivity and contrast not available in conventional microscopes

  14. Probing Positron Gravitation at HERA

    International Nuclear Information System (INIS)

    Gharibyan, Vahagn

    2015-07-01

    An equality of particle and antiparticle gravitational interactions holds in general relativity and is supported by indirect observations. Here I develop a method based on high energy Compton scattering to measure the gravitational interaction of accelerated charged particles. Within that formalism the Compton spectra measured at HERA rule out the positron's anti-gravity and hint for a positron's 1.3(0.2)% weaker coupling to the gravitational field relative to an electron.

  15. Probing Positron Gravitation at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Gharibyan, Vahagn

    2015-07-15

    An equality of particle and antiparticle gravitational interactions holds in general relativity and is supported by indirect observations. Here I develop a method based on high energy Compton scattering to measure the gravitational interaction of accelerated charged particles. Within that formalism the Compton spectra measured at HERA rule out the positron's anti-gravity and hint for a positron's 1.3(0.2)% weaker coupling to the gravitational field relative to an electron.

  16. Organic synthesis with short-lived positron-emitting radioisotopes

    International Nuclear Information System (INIS)

    Pike, V.W.

    1988-01-01

    Chemistry with short-lived positron-emitting radioisotopes of the non-metals, principally 11 C, 13 N and 18 F, has burgeoned over the last decade. This has been almost entirely because of the emergence of positron emission tomography (PET) as a powerful non-invasive technique for investigating pathophysiology in living man. PET is essentially an external technique for the rapid serial reconstruction of the spatial distribution of any positron-emitting radioisotope that has been administered in vivo. Such a distribution is primarily governed by the chemical form in which the positron-emitting radioisotope is incorporated, and importantly for clinical research, is often perturbed by physical, biological or clinical factors. Judicious choice of the chemical form enables specific biological information to be obtained. For example, the labelling of glucose with a positron-emitting radioisotope could be expected to provide a radiopharmaceutical for the study of glucose utilisation in both health and disease. (author)

  17. Positron trapping at defects in copper oxide superconductors

    International Nuclear Information System (INIS)

    McMullen, T.; Jena, P.; Khanna, S.N.; Li, Y.; Jensen, K.O.

    1991-01-01

    Positron states and lifetimes at defects in the copper oxide superconductors La 2-x Sr x CuO 4 , YBa 2 Cu 3 O 7-x , and Bi 2 Sr 2 CaCu 2 O 8+x are calculated with use of the superposed-atom model. In the Bi 2 Sr 2 CaCu 2 O 8+x compound, we find that the smaller metal-ion vacancies appear to only bind positrons weakly, while missing oxygens do not trap positrons. In contrast, metal-ion vacancies in La 2-x Sr x CuO 4 and YBa 2 Cu 3 O 7-x bind positrons by ∼1 eV, and oxygen-related defects appear to be the weak-binding sites in these materials. The sites that bind positrons only weakly, by energies ∼k BT , are of particular interest in view of the complex temperature dependences of the annihilation characteristics that are observed in these materials

  18. Positrons trapped in polyethylene: Electric field effect

    International Nuclear Information System (INIS)

    Bertolaccini, M.; Bisi, A.; Gambarini, G.; Zappa, L.

    1978-01-01

    The intensity of the iot 2 -component of positrons annihilated in polyethylene is found to increase with increasing electric field, while the formation probability of the positron state responsible for this component remains independent of the field. (orig.) 891 HPOE [de

  19. ANTICOOL: Simulating positron cooling and annihilation in atomic gases

    Science.gov (United States)

    Green, D. G.

    2018-03-01

    The Fortran program ANTICOOL, developed to simulate positron cooling and annihilation in atomic gases for positron energies below the positronium-formation threshold, is presented. Given positron-atom elastic scattering phase shifts, normalised annihilation rates Zeff, and γ spectra as a function of momentum k, ANTICOOL enables the calculation of the positron momentum distribution f(k , t) as a function of time t, the time-varying normalised annihilation rate Z¯eff(t) , the lifetime spectrum and time-varying annihilation γ spectra. The capability and functionality of the program is demonstrated via a tutorial-style example for positron cooling and annihilation in room temperature helium gas, using accurate scattering and annihilation cross sections and γ spectra calculated using many-body theory as input.

  20. Irradiation damage of alkali halide crystals during positron bombardment

    International Nuclear Information System (INIS)

    Arefiev, K.P.; Arefiev, V.P.; Vorobiev, S.A.

    1978-01-01

    The bleaching effect of positron irradiation of KCl and KBr single crystals previously coloured with electrons or protons was investigated. Positrons injection in the coloured alkali halide samples reduced the F-centres concentration considerably. For KCl crystals thicker than the positrons range the appearance of additional bands in the absorption spectra is noticeable. The experimental data show that the bleaching phenomenon should be observed merely throughout the positron exposure both for irradiated and non-irradiated regions of the sample. Irradiation effects, due to positron source, on the peak counting rate of (γ-γ) angular correlation in KCl crystals under applied magnetic field were also investigated. The growth of peak counting rate shows the increase of positronium-like states formation near defects of cation sublattice. (author)

  1. Positron emission tomographic imaging of tumors using monoclonal antibodies. Progress report, April 15, 1992--October 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Zalutsky, M.R.

    1992-08-01

    This research project is developing methods for utilizing positron emission tomography (PET) to increase the clinical potential of radiolabeled monoclonal antibodies (MAbs). This report describes the development of methods for labeling MAbs and their fragments with positron-emitting halogen nuclides, fluorine-18 and iodine-124. These nulides were selected because of the widespread availability of F-18 and because of our extensive experience in the development of new protein radiohalogenation methods.

  2. Potential advantages of a cesium fluoride scintillator for a time-of-flight positron camera

    International Nuclear Information System (INIS)

    Allemand, R.; Gresset, C.; Vacher, J.

    1980-01-01

    In order to improve the quality of positron tomographic imaging, a time-of-flight technique combined with a classical reconstruction method has been investigated. The decay time of NaI(Tl) and bismuth germanate (BGO) scintillators is too long for this application, and efficiency of the plastic scintillators is too low. Cesium fluoride appears to be a very promising detector material. This paper presents preliminary results obtained with a time-of-flight technique using CsF scintillators. The expected advantages were realized

  3. A question of balance: Kinetic balance for electrons and positrons

    International Nuclear Information System (INIS)

    Dyall, Kenneth G.

    2012-01-01

    Graphical abstract: Kinetic balance for both electrons and positrons is achieved by applying the correct relation for positive and negative energy states separately and then using the electron and positron eigensolutions from the separate diagonalizations of the Hamiltonian as a dual basis. Highlights: ► Kinetic balance for electrons and positrons is achieved in a dual atomic basis. ► Dual atomic balance alleviates, but does not eliminate, energy prolapse. ► Positron affinities converge quicker with basis set size with dual atomic balance. - Abstract: The kinetic balance criterion used in current relativistic basis set codes is satisfied by the electron solutions of the Dirac equation, but not the positron solutions. A proposal for applying kinetic balance to both sets of solutions is presented. The method is applied along with “normal” kinetic balance to one-electron systems, to investigate its possible relation to prolapse, and to the positron affinity of F − , to investigate the kinetic energy deficiency for positron solutions. The new method reduces but does not eliminate prolapse for energy-optimized basis sets, and provides faster and smoother convergence with basis set size for the positron affinity.

  4. Positron probing of electron momentum density in GaAs-AlAs superlattices and related materials

    International Nuclear Information System (INIS)

    Arutyunov, N.Y.; Sekkal, N.

    2008-08-01

    The band structure calculations based on the method proposed by Jaros et al. (Phys. Rev. B 31, 1205 (1985)) have been performed for the defect-free GaAs-AlAs superlattice and related AlAs and GaAs single crystals; the electron-positron momentum density distributions have been computed and analyzed. The results of calculations are in good agreement with the experimental data obtained ad hoc for GaAs and AlAs bulk materials by measuring the angular correlation of the annihilation radiation (ACAR). Small (but marked) features of the electron-positron momentum density of the valence band have been revealed both for constituent materials and GaAs-AlAs superlattice. The delocalization of positron in 'perfect' defect-'free' AlAs and GaAs single crystals to be observed experimentally is borne out by the results of pseudo-potential band calculations performed on the basis of method proposed by Sekkal et al. (Superlattices and Microstructures, 33, 63 (2003)). The prediction of the possibility of a certain confinement of positron in the interstitial area of GaAs- AlAs superlattice is confirmed by the agreement between the results of calculations and relevant experimental data obtained for GaAs and AlAs single crystals. No considerable effect of the enhancement of the annihilation rate (due to electron-positron interaction) upon the electron-positron momentum density distribution both in the superlattice and its constituent bulk materials has been found. The results of ACAR measurements and calculations performed suggest that a tangible improvement of the sensitivity of existing positron annihilation techniques is necessary for studying details of the electron-positron momentum density distributions in defect-'free' superlattices to be created on the basis of the diamond-like semiconductors possessing close values of the electron momentum densities. On the contrary, the positron-sensitive vacancy-type defects of various types in the superlattice may become a source of the

  5. Rhetoric and analogies

    OpenAIRE

    Aragonès, Enriqueta; Gilboa, Itzhak; Postlewaite, Andrew; Schmeidler, David; Universitat Autònoma de Barcelona. Unitat de Fonaments de l'Anàlisi Econòmica; Universitat Autònoma de Barcelona. Institut d'Anàlisi Econòmica

    2013-01-01

    The art of rhetoric may be defined as changing other people's minds (opinions, beliefs) without providing them new information. One tech- nique heavily used by rhetoric employs analogies. Using analogies, one may draw the listener's attention to similarities between cases and to re-organize existing information in a way that highlights certain reg- ularities. In this paper we offer two models of analogies, discuss their theoretical equivalence, and show that finding good analogies is a com- p...

  6. Positron annihilation studies on BeO powders

    International Nuclear Information System (INIS)

    Brauer, G.; Kerbe, F.; Kajcsos, Z.; Ashry, A.

    1984-01-01

    The sintering behaviour of two differently produced BeO powders is studied by positron annihilation. The positron lifetime in dislocations is found to be tau/sub d/ = (185 +- 2) ps, whereas for the perfect lattice tau/sub c/ = (130 +- 2) ps. (author)

  7. CO2 absorption of perovskites as seen by positron lifetime spectroscopy

    International Nuclear Information System (INIS)

    Suevegh, K.; Nomura, K.; Juhasz, G.; Homonnay, Z.; Vertes, A.

    2000-01-01

    The CO 2 absorption of several ABO 3 type perovskites was studied by positron lifetime spectroscopy. The longer positron lifetime was associated with positrons trapped by A site vacancies. The evaluated positron lifetime data indicated the relative stability of the crystal structure of Sr(Co 0.5 Fe 0.5 )O 3-δ against Ca doping at low Ca concentrations. Oxygen desorption and CO 2 absorption/desorption could also be followed by positron lifetime spectroscopy. It was shown that the concentration of oxygen vacancies has a large effect on positron lifetime data through the electron density of A site vacancies.

  8. Positron kinetics in an idealized PET environment

    Science.gov (United States)

    Robson, R. E.; Brunger, M. J.; Buckman, S. J.; Garcia, G.; Petrović, Z. Lj.; White, R. D.

    2015-08-01

    The kinetic theory of non-relativistic positrons in an idealized positron emission tomography PET environment is developed by solving the Boltzmann equation, allowing for coherent and incoherent elastic, inelastic, ionizing and annihilating collisions through positronium formation. An analytic expression is obtained for the positronium formation rate, as a function of distance from a spherical source, in terms of the solutions of the general kinetic eigenvalue problem. Numerical estimates of the positron range - a fundamental limitation on the accuracy of PET, are given for positrons in a model of liquid water, a surrogate for human tissue. Comparisons are made with the ‘gas-phase’ assumption used in current models in which coherent scattering is suppressed. Our results show that this assumption leads to an error of the order of a factor of approximately 2, emphasizing the need to accurately account for the structure of the medium in PET simulations.

  9. Monte Carlo simulation of positron induced secondary electrons in thin carbon foils

    International Nuclear Information System (INIS)

    Cai, L H; Yang, B; Ling, C C; Beling, C D; Fung, S

    2011-01-01

    Emission of secondary electrons induced by the passage of low energy positrons through thin carbon foils was studied by the Monte Carlo method. The positron and electron elastic cross sections were calculated by partial wave analysis. The inelastic positron-valence-electron was described by the energy loss function obtained from dielectric theory. The positron-core-electron interaction was modelled by the Gryzinski's excitation function. Positron transport inside the carbon foil was simulated in detail. Secondary electrons created by positrons and high energy secondary electrons through inelastic interactions were tracked through the foil. The positron transmission coefficient and secondary electron yielded in forward and backward geometry are calculated and dependences on positron energy and carbon foil thickness are discussed.

  10. Positron collisions with helium and alkaline earth-like atoms

    International Nuclear Information System (INIS)

    Campbell, C.P.

    1998-09-01

    This doctoral thesis is subdivided into: 1. Theory of positron collisions with helium and alkaline earth-like atoms, 2. Positron collisions with helium, magnesium, calcium, zinc, 3. Intercomparison of positron scattering by all those elements. The appendix of this work gives details of the numerical calculations and expands on the wavefunctions used

  11. Diagnostic merits of current and potential applications of single photon and positron imaging: a perspective

    Energy Technology Data Exchange (ETDEWEB)

    Harper, P. V.

    1978-01-01

    A brief review of the limitations of medical radionuclide imaging techniques in competition with x-ray CAT scanning and ultrasound suggest that the emphasis in this are should be on measurement of the physiologic uptake of tracer materials. Tomography greatly improves the possibilities of quantitation of this uptake - examples using positron and single photon techniques are presented for /sup 13/NH/sub 3/ and /sup 201/Tl in the heart.

  12. Design studies for the Positron Factory

    International Nuclear Information System (INIS)

    Okada, S.; Sunaga, H.; Kaneko, H.; Masuno, S.; Kawasuso, A.; Sakai, T.; Takizawa, H.; Yotsumoto, K.; Honda, Y.; Tagawa, S.

    1996-01-01

    In the design study for the Positron Factory, a feasibility of simultaneous extraction of multi-channel monoenergetic positron beams, which had been proposed at the previous conference (Linac 94), was demonstrated by an experiment using an electron linac. On the basis of the experimental result, an efficient moderator structure, which is composed of honeycomb-like assembled moderator foils and reflectors, is proposed. (author)

  13. Positron emission tomography of the heart

    International Nuclear Information System (INIS)

    Budinger, T.F.; Yano, Y.; Mathis, C.A.; Moyer, B.R.; Huesman, R.H.; Derenzo, S.E.

    1983-01-01

    Positron emission tomography (PET) offers the opportunity to noninvasively measure heart muscle blood perfusion, oxygen utilization, metabolism of fatty acids, sugars and amino acids. This paper reviews physiological principles which are basic to PET instrumentation for imaging the heart and gives examples of the application of positron emission tomography for measuring myocardial flow and metabolism. 33 references, 11 figures, 1 table

  14. Positron emission tomography in drug development

    International Nuclear Information System (INIS)

    Rubin, R. H.; Fischman, A. J.

    1997-01-01

    There are four kinds of measurements that can be carried out with positron emission tomography (PET) that can contribute significantly to the process of drug development: pharmacodynamic measurement of tissue metabolism influenced by a given drug; precise measurements of tissue blood flow; tissue pharmacokinetics of a given drug following administration of a particular dose; and the temporal course of ligand-receptor interaction. One or more of these measurements can greatly improve the decision making involved in determining the appropriate dose of a drug, the clinical situations in which a drug might be useful, and the linkage of pharmacokinetics with pharmacodynamics, which is at the heart of effective drug development. The greater the potential of a particular compound as a therapeutic agent, the greater the potential for PET to contribute to the drug development process

  15. Bayesian analogy with relational transformations.

    Science.gov (United States)

    Lu, Hongjing; Chen, Dawn; Holyoak, Keith J

    2012-07-01

    How can humans acquire relational representations that enable analogical inference and other forms of high-level reasoning? Using comparative relations as a model domain, we explore the possibility that bottom-up learning mechanisms applied to objects coded as feature vectors can yield representations of relations sufficient to solve analogy problems. We introduce Bayesian analogy with relational transformations (BART) and apply the model to the task of learning first-order comparative relations (e.g., larger, smaller, fiercer, meeker) from a set of animal pairs. Inputs are coded by vectors of continuous-valued features, based either on human magnitude ratings, normed feature ratings (De Deyne et al., 2008), or outputs of the topics model (Griffiths, Steyvers, & Tenenbaum, 2007). Bootstrapping from empirical priors, the model is able to induce first-order relations represented as probabilistic weight distributions, even when given positive examples only. These learned representations allow classification of novel instantiations of the relations and yield a symbolic distance effect of the sort obtained with both humans and other primates. BART then transforms its learned weight distributions by importance-guided mapping, thereby placing distinct dimensions into correspondence. These transformed representations allow BART to reliably solve 4-term analogies (e.g., larger:smaller::fiercer:meeker), a type of reasoning that is arguably specific to humans. Our results provide a proof-of-concept that structured analogies can be solved with representations induced from unstructured feature vectors by mechanisms that operate in a largely bottom-up fashion. We discuss potential implications for algorithmic and neural models of relational thinking, as well as for the evolution of abstract thought. Copyright 2012 APA, all rights reserved.

  16. AMS-02 positron excess and indirect detection of three-body decaying dark matter

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Hsin-Chia [Department of Physics, University of California, Davis, CA 95616 (United States); Huang, Wei-Chih [Fakultät für Physik, Technische Universität Dortmund, 44221 Dortmund (Germany); Huang, Xiaoyuan [Physik-Department T30d, Technische Universität München, James-Franck-Straße, D-85748 Garching (Germany); Low, Ian [High Energy Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Tsai, Yue-Lin Sming [Kavli IPMU (WPI), University of Tokyo, Kashiwa, Chiba 277-8583 (Japan); Yuan, Qiang, E-mail: cheng@physics.ucdavis.edu, E-mail: wei-chih.huang@tu-dortmund.de, E-mail: huangxiaoyuan@gmail.com, E-mail: ilow@northwestern.edu, E-mail: smingtsai@gmail.com, E-mail: yuanq@pmo.ac.cn [Key Laboratory of Dark Matter and Space Astronomy, Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing 210008 (China)

    2017-03-01

    We consider indirect detection of meta-stable dark matter particles decaying into a stable neutral particle and a pair of standard model fermions. Due to the softer energy spectra from the three-body decay, such models could potentially explain the AMS-02 positron excess without being constrained by the Fermi-LAT gamma-ray data and the cosmic ray anti-proton measurements. We scrutinize over different final state fermions, paying special attention to handling of the cosmic ray background and including various contributions from cosmic ray propagation with the help of the LIKEDM package. It is found that primary decays into an electron-positron pair and a stable neutral particle could give rise to the AMS-02 positron excess and, at the same time, stay unscathed against the gamma-ray and anti-proton constraints. Decays to a muon pair or a mixed flavor electron-muon pair may also be viable depending on the propagation models. Decays to all other standard model fermions are severely disfavored.

  17. Hydrogen interaction with oxidized Si(111) probed with positrons

    International Nuclear Information System (INIS)

    Lynn, K.G.; Nielsen, B.; Welch, D.O.

    1989-01-01

    A variable-energy positron beam was utilized to study the interface action of hydrogen with Si(111) covered by an ultrahigh-vacuum thermally grown oxide of 2-3 nm thickness. It was observed that positrons implanted at shallow depth (< 100 nm) after diffusion are trapped either at the interface between the oxide and the Si or in the oxide. The positron-annihilation characteristics of these trapped positrons are found to be very sensitive to hydrogen exposure. The momentum distribution of the annihilating positron-electron pair, as observed in the Doppler broadening of the annihilation line, broadens considerably after exposure to hydrogen. The effect recovers after annealing at ≅ 1100 K, suggesting a hydrogen binding at the interface of ∼ 3 ± 0.3 eV. (author). 18 refs., 3 figs

  18. Intuitive analog circuit design

    CERN Document Server

    Thompson, Marc

    2013-01-01

    Intuitive Analog Circuit Design outlines ways of thinking about analog circuits and systems that let you develop a feel for what a good, working analog circuit design should be. This book reflects author Marc Thompson's 30 years of experience designing analog and power electronics circuits and teaching graduate-level analog circuit design, and is the ideal reference for anyone who needs a straightforward introduction to the subject. In this book, Dr. Thompson describes intuitive and ""back-of-the-envelope"" techniques for designing and analyzing analog circuits, including transistor amplifi

  19. LEP - Large Electron Positron Exhibition LEPFest 2000

    CERN Multimedia

    2000-01-01

    The Large Electron-Positron Collider (LEP) is 27 km long. Its four detectors (ALEPH, DELPHI, L3, OPAL) measure precisely what happens in the collisions of electrons and positrons. These conditions only exist-ed in the Universe when it was about 10 -10 sec old.

  20. Applications and advances of positron beam spectroscopy: appendix a

    Energy Technology Data Exchange (ETDEWEB)

    Howell, R. H., LLNL

    1997-11-05

    Over 50 scientists from DOE-DP, DOE-ER, the national laboratories, academia and industry attended a workshop held on November 5-7, 1997 at Lawrence Livermore National Laboratory jointly sponsored by the DOE-Division of Materials Science, The Materials Research Institute at LLNL and the University of California Presidents Office. Workshop participants were charged to address two questions: Is there a need for a national center for materials analysis using positron techniques and can the capabilities at Lawrence Livermore National Laboratory serve this need. To demonstrate the need for a national center the workshop participants discussed the technical advantages enabled by high positron currents and advanced measurement techniques, the role that these techniques will play in materials analysis and the demand for the data. There were general discussions lead by review talks on positron analysis techniques, and their applications to problems in semiconductors, polymers and composites, metals and engineering materials, surface analysis and advanced techniques. These were followed by focus sessions on positron analysis opportunities in these same areas. Livermore now leads the world in materials analysis capabilities by positrons due to developments in response to demands of science based stockpile stewardship. There was a detailed discussion of the LLNL capabilities and a tour of the facilities. The Livermore facilities now include the worlds highest current beam of keV positrons, a scanning pulsed positron microprobe under development capable of three dimensional maps of defect size and concentration, an MeV positron beam for defect analysis of large samples, and electron momentum spectroscopy by positrons. This document is a supplement to the written summary report. It contains a complete schedule, list of attendees and the vuegraphs for the presentations in the review and focus sessions.

  1. Analysis of experimental positron-molecule binding energies

    International Nuclear Information System (INIS)

    Danielson, J R; Surko, C M; Young, J A

    2010-01-01

    Experiments show that positron annihilation on molecules frequently occurs via capture into vibrational Feshbach resonances. In these cases, the downshifts in the annihilation spectra from the vibrational mode spectra provide measures of the positron-molecule binding energies. An analysis of these binding energy data is presented in terms of the molecular dipole polarizability, the permanent dipole moment, and the number of π bonds in aromatic molecules. The results of this analysis are in reasonably good agreement with other information about positron-molecule bound states. Predictions for other targets and promising candidate molecules for further investigation are discussed.

  2. Positron production in heavy ion-atom collisions

    International Nuclear Information System (INIS)

    Kienle, P.

    1985-08-01

    Following an introduction into the concept of an atom with an overcritical field, established by a nucleus with a charge larger than 173, the spontaneous positron emission from such an atom with an 1s binding energy exceeding 2mc 2 is presented. Such a process, in which an electron is bound and a monoenergetic positron emitted turns the neutral into a charged vacuum. In a U-U di-nuclear system (Z=184) the spontaneous positron emission proceeds with an energy of about 300 keV corresponding to a decay time of 3x10 -19 sec. (orig./WL)

  3. Experimental Observation of a Current-Driven Instability in a Neutral Electron-Positron Beam.

    Science.gov (United States)

    Warwick, J; Dzelzainis, T; Dieckmann, M E; Schumaker, W; Doria, D; Romagnani, L; Poder, K; Cole, J M; Alejo, A; Yeung, M; Krushelnick, K; Mangles, S P D; Najmudin, Z; Reville, B; Samarin, G M; Symes, D D; Thomas, A G R; Borghesi, M; Sarri, G

    2017-11-03

    We report on the first experimental observation of a current-driven instability developing in a quasineutral matter-antimatter beam. Strong magnetic fields (≥1  T) are measured, via means of a proton radiography technique, after the propagation of a neutral electron-positron beam through a background electron-ion plasma. The experimentally determined equipartition parameter of ε_{B}≈10^{-3} is typical of values inferred from models of astrophysical gamma-ray bursts, in which the relativistic flows are also expected to be pair dominated. The data, supported by particle-in-cell simulations and simple analytical estimates, indicate that these magnetic fields persist in the background plasma for thousands of inverse plasma frequencies. The existence of such long-lived magnetic fields can be related to analog astrophysical systems, such as those prevalent in lepton-dominated jets.

  4. NaturAnalogs for the Unsaturated Zone

    Energy Technology Data Exchange (ETDEWEB)

    A. Simmons; A. Unger; M. Murrell

    2000-03-08

    The purpose of this Analysis/Model Report (AMR) is to document natural and anthropogenic (human-induced) analog sites and processes that are applicable to flow and transport processes expected to occur at the potential Yucca Mountain repository in order to build increased confidence in modeling processes of Unsaturated Zone (UZ) flow and transport. This AMR was prepared in accordance with ''AMR Development Plan for U0135, Natural Analogs for the UZ'' (CRWMS 1999a). Knowledge from analog sites and processes is used as corroborating information to test and build confidence in flow and transport models of Yucca Mountain, Nevada. This AMR supports the Unsaturated Zone (UZ) Flow and Transport Process Model Report (PMR) and the Yucca Mountain Site Description. The objectives of this AMR are to test and build confidence in the representation of UZ processes in numerical models utilized in the UZ Flow and Transport Model. This is accomplished by: (1) applying data from Boxy Canyon, Idaho in simulations of UZ flow using the same methodologies incorporated in the Yucca Mountain UZ Flow and Transport Model to assess the fracture-matrix interaction conceptual model; (2) Providing a preliminary basis for analysis of radionuclide transport at Pena Blanca, Mexico as an analog of radionuclide transport at Yucca Mountain; and (3) Synthesizing existing information from natural analog studies to provide corroborating evidence for representation of ambient and thermally coupled UZ flow and transport processes in the UZ Model.

  5. Natural Analogs for the Unsaturated Zone

    International Nuclear Information System (INIS)

    Simmons, A.; Unger, A.; Murrell, M.

    2000-01-01

    The purpose of this Analysis/Model Report (AMR) is to document natural and anthropogenic (human-induced) analog sites and processes that are applicable to flow and transport processes expected to occur at the potential Yucca Mountain repository in order to build increased confidence in modeling processes of Unsaturated Zone (UZ) flow and transport. This AMR was prepared in accordance with ''AMR Development Plan for U0135, Natural Analogs for the UZ'' (CRWMS 1999a). Knowledge from analog sites and processes is used as corroborating information to test and build confidence in flow and transport models of Yucca Mountain, Nevada. This AMR supports the Unsaturated Zone (UZ) Flow and Transport Process Model Report (PMR) and the Yucca Mountain Site Description. The objectives of this AMR are to test and build confidence in the representation of UZ processes in numerical models utilized in the UZ Flow and Transport Model. This is accomplished by: (1) applying data from Boxy Canyon, Idaho in simulations of UZ flow using the same methodologies incorporated in the Yucca Mountain UZ Flow and Transport Model to assess the fracture-matrix interaction conceptual model; (2) Providing a preliminary basis for analysis of radionuclide transport at Pena Blanca, Mexico as an analog of radionuclide transport at Yucca Mountain; and (3) Synthesizing existing information from natural analog studies to provide corroborating evidence for representation of ambient and thermally coupled UZ flow and transport processes in the UZ Model

  6. Millimeter positron focusing using a hybrid lens design

    International Nuclear Information System (INIS)

    Cheung, C.K.; Kwan, P.Y.; Shan, Y.Y.; Naik, P.S.; Weng, H.M.; Beling, C.D.; Fung, S.

    2004-01-01

    The study of metal-semiconductor and metal-oxide-semiconductor systems with low energy positrons is made considerably easier if structures of millimeter dimension can be studied. For this reason the production of a positron beam of sub-millimeter dimension has been a long-term goal of the positron research group at the university of Hong Kong. The hybrid lens system employed consists of a standard Soa extraction lens in a magnetic field free region followed by a gridded Einzel lens that focuses positrons into a 100G magnetic funnel at an energy of 10keV for transportation to the target. Here we report on the present progress, by showing the capability of obtaining millimeter diameter focusing at a preliminary 7.5 kV beam energy. (orig.)

  7. Production of slow-positron beams with an electron linac

    International Nuclear Information System (INIS)

    Howell, R.H.; Alvarez, R.A.; Stanek, M.

    1982-01-01

    Intense, pulsed beams of low-energy positrons have been produced by a high-energy beam from an electron linac. The production efficiency for low-energy positrons has been determined for electrons with 60 to 120 MeV energy, low-energy positron beams from a linac can be of much higher intensity than those beams currently derived from radioactive sources

  8. Development of positron diffraction and holography at LLNL

    International Nuclear Information System (INIS)

    Hamza, A.; Asoka-Kumar, P.; Stoeffl, W.; Howell, R.; Miller, D.; Denison, A.

    2003-01-01

    A low-energy positron diffraction and holography spectrometer is currently being constructed at the Lawrence Livermore National Laboratory (LLNL) to study surfaces and adsorbed structures. This instrument will operate in conjunction with the LLNL intense positron beam produced by the 100 MeV LINAC allowing data to be acquired in minutes rather than days. Positron diffraction possesses certain advantages over electron diffraction which are discussed. Details of the instrument based on that of low-energy electron diffraction are described

  9. Positron lifetime spectroscopy of internally oxidised Ag-In alloys

    International Nuclear Information System (INIS)

    Wegner, D.; Lieb, K.P.

    1989-01-01

    The effects of In 2 O 3 precipitates on positron lifetimes after internal oxidation of α-Ag-In alloys have been investigated. A positron trap associated with the lifetime τ 205(3) ps was detected. On the basis of the experimental results obtained for different oxidation kinetics parameters, a trapping model is proposed according to which positrons thermalised in a dislocation field around oxide precipitates are trapped at the oxide/metal phase boundary. The transition from internal to external oxidation of Ag-In was also studied. The positron lifetime in In 2 O 3 was measured to be τ = 263(8) ps. (author)

  10. Positron and positronium annihilation in low-dielectric-constant films studied by a pulsed positron beam

    International Nuclear Information System (INIS)

    Suzuki, R.; Ohdaira, T.; Kobayashi, Y.; Ito, K.; Yu, R.S.; Shioya, Y.; Ichikawa, H.; Hosomi, H.; Ishikiriyama, K.; Shirataki, H.; Matsuno, S.; Xu, J.

    2004-01-01

    Positron and positronium annihilation in porous low-dielectric-constant (low-k) films deposited by plasma-enhanced chemical vapor deposition (PECVD) and spin-on dielectric (SOD) have been investigated by means of positron annihilation lifetime spectroscopy (PALS) and age-momentum correlation (AMOC) spectroscopy with a pulsed slow positron beam. The ortho-positronium (o-Ps) lifetime strongly depends on the deposition condition. In general, PECVD low-k films have shorter o-Ps lifetimes than SOD low-k films, indicating PECVD low-k films have smaller pores. Since o-Ps diffusion and escaping from the surface occurs in most of porous SOD films, three-gamma annihilation measurement is important. To investigate o-Ps behavior in SOD films, we have carried out two-dimensional (2D) PALS measurement, which measures annihilation time and pulse-height of the scintillation detector simultaneously. Monte-Carlo simulation of the o-Ps diffusion and escaping in porous films has been carried out to simulate the 2D-PALS results. (orig.)

  11. Bremsstrahlung Based Positron Annihilation Spectroscopy for Material Defect Analysis

    International Nuclear Information System (INIS)

    Selim, F.A.; Wells, D.P.; Harmon, F.; Kwofie, J.; Lancaster, G.; Jones, J.L.

    2003-01-01

    The Idaho Accelerator Center (IAC) has developed new techniques for Positron Annihilation Spectroscopy (PAS) using highly penetrating γ-rays to create positrons inside the material via pair production. γ-Ray induced positron annihilation spectroscopy can provide highly penetrating probes for material characterization and defect analysis. Bremsstrahlung beams from small, pulsed electron Linacs (6 MeV) have been used to bombard the materials to generate positrons, which annihilate with the material electrons emitting 511 keV radiation. We have also synchronized bremsstrahlung pulses with laser irradiation pulses to study dynamic structural changes in material. In addition, we have developed another method using (p,γ) reactions from a 2 MeV proton beam, which induce coincident γ-rays to perform positron life-time spectroscopy. We have showed the feasibility of extending PAS into thick samples and a wide variety of materials and industrial applications

  12. On new developments in the physics of positron swarms

    International Nuclear Information System (INIS)

    Petrovic, Z Lj; Bankovic, A; Dujko, S; Marjanovic, S; Suvakov, M; Malovic, G; Marler, J P; Buckman, S J; White, R D; Robson, R E

    2010-01-01

    Recently a new wave of swarm studies of positrons was initiated based on more complete scattering cross section sets. Initially some interesting and new physics was discovered, most importantly negative differential conductivity (NDC) that occurs only for the bulk drift velocity while it does not exist for the flux property. However the ultimate goal was to develop tools to model positron transport in realistic applications and the work that is progressing along these lines is reviewed here. It includes studies of positron transport in molecular gases, thermalization in generic swarm situations and in realistic gas filled traps and transport of positrons in crossed electric and magnetic fields. Finally we have extended the same technique of simulation (Monte Carlo) to studies of thermalization of positronium molecule. In addition, recently published first steps towards including effects of dense media on positron transport are summarized here.

  13. Positron annihilation in corrosion protective polymeric coatings. Pt. 2

    International Nuclear Information System (INIS)

    Szeles, C.; Vertes, A.; White, M.L.; Leidheiser, H. Jr.; Lehigh Univ., Bethlehem, PA

    1988-01-01

    Positron annihilation was studied in four commercial polymeric coatings on iron. Positron lifetime measurements were performed before and after exposure of the coatings to boiling water for 1 h. A correlation was observed between the effect of water exposure on the lifetime spectra and the protective properties of the coatings when exposed to 0.1M sulfuric acid at 60 0 C for 1010 h. The coatings that provided good corrosion protection in the acid showed minor changes in the positron lifetime spectra upon exposure to water. The spectra of coatings that showed poor corrosion protection in the acid showed minor changes in the positron lifetime spectra upon exposure to water. The spectra of coatings that showed poor corrosion protection, on the other hand, exhibited considerable changes in the positron lifetime spectra upon exposure to water. (orig.)

  14. 22 Na positron source for annihilation positron spectroscopy

    International Nuclear Information System (INIS)

    Cimpeanu, Catalina; Craciun, Liviu; Dragulescu, Emilian; Dudu, Dorin; Racolta, Petre Mihai; Voiculescu, Dana; Miron, N.

    2005-01-01

    To extend the nuclear physics applications and to perform the study of vacancy - type defects in metals, semiconductors, polymers, etc., we developed new positron annihilation techniques. In line with this goal we started a project for production of positron sources at the IFIN-HH U-120 Cyclotron. We made use of the nuclear reaction: 24 Mg(d,α) 22 Na with deuterons of 13 MeV energy. The paper present the main steps of this procedure which are: establishing the conditions required for 22 NaCl sources, for the parameters of reaction chamber and the characteristics of Mg target, parameters for the irradiation, radiochemical procedures for separation of Na from Mg after irradiation as well as the geometrical and mechanical requirements for the NaCl source. In the e + lifetime measurements the e + 'stop' signals are always provided by gamma - quanta generated by the e + e - annihilation and the 'start' signals are obtained from 'prompt' gamma - quanta emitted by the NaCl source (1.275 MeV photons). The 22 NaCl stock solution obtained by radiochemical separation will be kept in quartz sealed ampoules. (authors)

  15. Electron-positron interactions

    International Nuclear Information System (INIS)

    Wiik, B.; Wolf, G.

    1979-01-01

    This book is an introduction into the physics of electron-positron interactions. After a description of electron-positron storage rings pure electromagnetic e + e - interactions, and the total cross section are considered. Then low energy processes, the production of the J/psi and psi' particles including their radiative decay as well as the search for other narrow vector states are described. Then after the quark model interpretation of J/psi and psi' charmed mesons, the heavy lepton t, and the upsilon resonances are described. Thereafter inclusive hadron production and jet formation is discussed. Finally the next generation of e + e - colliding rings is described, and the first results from PETRA are presented. This book is suited for all physicists, who want to get a general review about e + e - physics. (HSI) 891 HSI/HSI 892 RKD

  16. Positron transport: The plasma-gas interface

    International Nuclear Information System (INIS)

    Marler, J. P.; Petrovic, Z. Lj.; Bankovic, A.; Dujko, S.; Suvakov, M.; Malovic, G.; Buckman, S. J.

    2009-01-01

    Motivated by an increasing number of applications, new techniques in the analysis of electron transport have been developed over the past 30 years or so, but similar methods had yet to be applied to positrons. Recently, an in-depth look at positron transport in pure argon gas has been performed using a recently established comprehensive set of cross sections and well-established Monte Carlo simulations. The key novelty as compared to electron transport is the effect of positronium formation which changes the number of particles and has a strong energy dependence. This coupled with spatial separation by energy of the positron swarm leads to counterintuitive behavior of some of the transport coefficients. Finally new results in how the presence of an applied magnetic field affects the transport coefficients are presented.

  17. The Correlation Between Dislocations and Vacancy Defects Using Positron Annihilation Spectroscopy

    Science.gov (United States)

    Pang, Jinbiao; Li, Hui; Zhou, Kai; Wang, Zhu

    2012-07-01

    An analysis program for positron annihilation lifetime spectra is only applicable to isolated defects, but is of no use in the presence of defective correlations. Such limitations have long caused problems for positron researchers in their studies of complicated defective systems. In order to solve this problem, we aim to take a semiconductor material, for example, to achieve a credible average lifetime of single crystal silicon under plastic deformation at different temperatures using positron life time spectroscopy. By establishing reasonable positron trapping models with defective correlations and sorting out four lifetime components with multiple parameters, as well as their respective intensities, information is obtained on the positron trapping centers, such as the positron trapping rates of defects, the density of the dislocation lines and correlation between the dislocation lines, and the vacancy defects, by fitting with the average lifetime with the aid of Matlab software. These results give strong grounds for the existence of dislocation-vacancy correlation in plastically deformed silicon, and lay a theoretical foundation for the analysis of positron lifetime spectra when the positron trapping model involves dislocation-related defects.

  18. Measurement of characteristic X-rays by positron impact

    International Nuclear Information System (INIS)

    Nagashima, Y.; Saito, F.; Itoh, Y.; Goto, A.; Hyodo, T.

    2004-01-01

    An X-ray detector with thin Si(Li) crystals has been fabricated and employed to detect the characteristic X-rays by positron impact. Use of thin detector crystals is essential for the measurements of the characteristic X-rays induced by positron impact. Otherwise the background produced in the crystals by the annihilation γ-rays is too large to isolate the X-ray peaks. The data has been analyzed to obtain the inner-shell ionization cross sections by positron impact. (orig.)

  19. Positron emission tomography - a new approach to brain chemistry

    International Nuclear Information System (INIS)

    Jacobson, H.G.

    1988-01-01

    Positron emission tomography permits examination of the chemistry of the brain in living beings. Until recently, positron emission tomography had been considered a research tool, but it is rapidly moving into clinical practice. This report describes the uses and applications of positron emission tomography in examinations of patients with strokes, epilepsy, malignancies, dementias, and schizophrenia and in basic studies of synaptic neurotransmission

  20. Measurement of positron range in matter in strong magnetic fields

    International Nuclear Information System (INIS)

    Hammer, B.E.; Christensen, N.L.

    1995-01-01

    Positron range is one factor that places a limitation on Positron Emission Tomography (PET) resolution. The distance a positron travels through matter before it annihilates with an electron is a function of its initial energy and the electron density of the medium. A strong magnetic field limits positron range when momentum components are transverse to the field. Measurement of positron range was determined by deconvolving the effects of detector response and radioactive distribution from the measured annihilation spread function. The annihilation spread function for a 0.5 mm bead of 68 Ga was measured with 0.2 and 1.0 mm wide slit collimators. Based on the annihilation spread function FWHM (Full Width at Half Maximum) for a 1.0 mm wide slit the median positron range in tissue equivalent material is 0.87, 0.50, 0.22 mm at 0, 5.0 and 9.4 T, respectively

  1. High-speed and high-resolution analog-to-digital and digital-to-analog converters

    NARCIS (Netherlands)

    van de Plassche, R.J.

    1989-01-01

    Analog-to-digital and digital-to-analog converters are important building blocks connecting the analog world of transducers with the digital world of computing, signal processing and data acquisition systems. In chapter two the converter as part of a system is described. Requirements of analog

  2. Rubrolides as model for the development of new lactones and their aza analogs as potential photosynthesis inhibitors.

    Science.gov (United States)

    Pereira, Ulisses A; Barbosa, Luiz C A; Demuner, Antônio J; Silva, Antônio A; Bertazzini, Michele; Forlani, Giuseppe

    2015-07-01

    Natural phytotoxins and their synthetic analogs are a potential source of new bioactive compounds for agriculture. Analogs of rubrolides, a class of γ-alkylidene-γ-lactones isolated from different ascidians, have been shown to interfere with the photosynthetic electron-transport chain, yet their activity needs to be improved. With this aim, ten 5-aryl-6-benzyl-4-bromopyridazin-3(2H)-ones were prepared in yields ranging from 44 to 88% by reaction of their correspondent γ-alkylidene-γ-lactones with NH2 NH2 . The structures of these rubrolide analogs were determined by (1) H- and (13) C-NMR, 2D-NMR (COSY and HETCOR), NOE difference, and MS techniques. These compounds were evaluated for their abilities of interfering with the light-driven reduction of ferricyanide by isolated spinach chloroplasts. Lactones with electron-withdrawing substituents in the para-position of the benzylidene ring were the most effective inhibitors. Characterization of the activity of 11b/11b' suggested a mechanism based on the interaction with the plastoquinone binding site of photosystem II. Addition of several compounds to the culture medium of a cyanobacterial model strain was found to inhibit algal growth. However, the relative effectiveness was not consistent with their activity in vitro, suggesting the occurrence of multiple targets and/or detoxyfication mechanisms. Indeed, the compounds showed differential effects on the heterotrophic growth of some crop species, Cucumis sativus and Sorghum bicolor. Pyridazin-3(2H)-ones 12e, 12i, and 12j, which have been found poorly active against the photosynthetic electron transport, were the most effective in inhibiting the growth of some weeds, Ipomoea grandifolia and Brachiaria decumbens, under greenhouse conditions. Copyright © 2015 Verlag Helvetica Chimica Acta AG, Zürich.

  3. Effect of dipole polarizability on positron binding by strongly polar molecules

    International Nuclear Information System (INIS)

    Gribakin, G F; Swann, A R

    2015-01-01

    A model for positron binding to polar molecules is considered by combining the dipole potential outside the molecule with a strongly repulsive core of a given radius. Using existing experimental data on binding energies leads to unphysically small core radii for all of the molecules studied. This suggests that electron–positron correlations neglected in the simple model play a large role in determining the binding energy. We account for these by including the polarization potential via perturbation theory and non-perturbatively. The perturbative model makes reliable predictions of binding energies for a range of polar organic molecules and hydrogen cyanide. The model also agrees with the linear dependence of the binding energies on the polarizability inferred from the experimental data (Danielson et al 2009 J. Phys. B: At. Mol. Opt. Phys. 42 235203). The effective core radii, however, remain unphysically small for most molecules. Treating molecular polarization non-perturbatively leads to physically meaningful core radii for all of the molecules studied and enables even more accurate predictions of binding energies to be made for nearly all of the molecules considered. (paper)

  4. Measurement of positron reemission from thin single-crystal W(100) films

    International Nuclear Information System (INIS)

    Chen, D.M.; Lynn, K.G.; Pareja, R.; Nielsen, B.

    1985-01-01

    Epitaxial thin single-crystal (100) tungsten films 1000, 2500, and 5000 A thick have been fabricated by high-vacuum electron-beam evaporation. These films were subsequently used as thin-film moderators for the study of the positron-transmission-reemission process with a variable-energy (0--80 keV) monoenergetic positron beam in an ultrahigh-vacuum system. The films were shown to be routinely cleanable by heating first in oxygen (10 -6 Torr) and then in vacuum (10 -9 Torr). Transmission and back reemission of slow positrons from these surfaces was observed. The positron work function, phi/sub +/ has been determined to be approx. =3.0 eV ( +- 0.3 eV). The transmission slow positrons were emitted in a narrow cone with a full width at half maximum of approx. =30 0 consistent with the angular distribution of back-reemission positrons. The reemitted yields as a function of incident positron energy were found to be very different between forward reemission and back reemission. The maximum forward-reemission yields were 18% for 1000-A-thick W film and 12% for 2500-A-thick W film at 5 and 10 keV optimum incident positron energies, respectively. These results show that one can use thin single-crystal tungsten films as positron moderators or remoderators

  5. Towards TeV-scale electron-positron collisions: the Compact Linear Collider (CLIC)

    Science.gov (United States)

    Doebert, Steffen; Sicking, Eva

    2018-02-01

    The Compact Linear Collider (CLIC), a future electron-positron collider at the energy frontier, has the potential to change our understanding of the universe. Proposed to follow the Large Hardron Collider (LHC) programme at CERN, it is conceived for precision measurements as well as for searches for new phenomena.

  6. Application of positron annihilation techniques for semiconductor studies

    International Nuclear Information System (INIS)

    Karwasz, G.P.; Zecca, A.; Brusa, R.S.; Pliszka, D.

    2004-01-01

    Positron annihilation techniques, being non-destructive, allowing depth profiling down to a few micrometers and detecting open-volume defects (vacancies, dislocations etc.) at single ppm concentrations constitute a valuable and complementary method, compared to other solid-state-physics studies. We give examples of investigation in the field of semiconductors with different techniques, both with and without use of positron low-energy beams. The Doppler broadening of the 511 keV annihilation line method and the slow positron beam were used to study helium-implanted silicon and the surface reduction processes in semiconducting glasses. The positron lifetime technique and coincidence spectra of the Doppler broadening were used for systematic studies of metals and semiconductors. Doppler-coincidence method was then used to identify the kinetics of oxygen precipitates in Czochralski-grown silicon

  7. Study of Si/Si, Si/SiO2, and metal-oxide-semiconductor (MOS) using positrons

    International Nuclear Information System (INIS)

    Leung, To Chi.

    1991-01-01

    A variable-energy positron beam is used to study Si/Si, Si/SiO 2 , and metal-oxide-semiconductor (MOS) structures. The capability of depth resolution and the remarkable sensitivity to defects have made the positron annihilation technique a unique tool in detecting open-volume defects in the newly innovated low temperature (300C) molecular-beam-epitaxy (MBE) Si/Si. These two features of the positron beam have further shown its potential role in the study of the Si/SiO 2 . Distinct annihilation characteristics has been observed at the interface and has been studied as a function of the sample growth conditions, annealing (in vacuum), and hydrogen exposure. The MOS structure provides an effective way to study the electrical properties of the Si/SiO 2 interface as a function of applied bias voltage. The annihilation characteristics show a large change as the device condition is changed from accumulation to inversion. The effect of forming gas (FG) anneal is studied using positron annihilation and the result is compared with capacitance-voltage (C-V) measurements. The reduction in the number of interface states is found correlated with the changes in the positron spectra. The present study shows the importance of the positron annihilation technique as a non-contact, non-destructive, and depth-sensitive characterization tool to study the Si-related systems, in particular, the Si/SiO 2 interface which is of crucial importance in semiconductor technology, and fundamental understanding of the defects responsible for degradation of the electrical properties

  8. Developments on positron scattering experiments including beam production and detection

    International Nuclear Information System (INIS)

    Selim, F.A.; Golovchenko, J.A.

    2001-01-01

    Positron scattering and channeling experiments require high quality (low emittance) beams. A new electrostatic optics system for extracting positrons from a moderator is presented. The system features improved efficiency of focusing and beam transport of moderated positrons emitted with angular spreads up to ± 30 , with good phase space characteristics. The presented optics also provides a high degree of freedom in controlling exit beam trajectories. The system has been installed in the LLNL Pelletron accelerator and showed great enhancement on the beam quality. On the detection side, image plates were used to measure the angular distributions of positrons transmitted through the gold crystals. The measurements demonstrate the advantages of image plates as quantitative position sensitive detectors for positrons. (orig.)

  9. Positron prevacancy effects in pure annealed metals

    International Nuclear Information System (INIS)

    Smedskjaer, L.C.

    1981-06-01

    The low-temperature prevacancy effects sometimes observed with positrons in well-annealed high-purity metals are discussed. It is shown that these effects are not experimental artifacts, but are due to trapping of the positrons. It is suggested that dislocations are responsible for these trapping effects. 46 references, 5 figures

  10. A multicrystal positron scanner for quantitative studies with positron-emitting radionuclides

    International Nuclear Information System (INIS)

    Ostertag, H.; Kuebler, W.; Kubesch, R.; Lorenz, W.J.

    1981-01-01

    A non-tomographic multicrystal whole-body scanner for quantitative positron imaging has been designed. The detector system consists of 64 coincidence detector pairs arranged in two opposing detector banks. NaI crystals of 38-mm diameter and 76-mm length are used. The patient moves linearly between the stationary transverse detector banks. The scanning area is 64-cm wide and up to 192-cm long. The spatial resolution is 2 cm at a sampling distance of 1 cm. The plane sensitivity amounts to 6400 counts/s for a pure positron emitter of 1 μCi/cm 2 . The accuracy of quantitative activity measurements is better than +- 15% for activities up to a few μCi/cm 2 . The design of the instrument, and its capabilities and limitations, are discussed. Initial experimental and clinical results are presented. (author)

  11. Characterization of a transmission positron/positronium converter for antihydrogen production

    Science.gov (United States)

    Aghion, S.; Amsler, C.; Ariga, T.; Bonomi, G.; Brusa, R. S.; Caccia, M.; Caravita, R.; Castelli, F.; Cerchiari, G.; Comparat, D.; Consolati, G.; Demetrio, A.; Di Noto, L.; Doser, M.; Ereditato, A.; Evans, C.; Ferragut, R.; Fesel, J.; Fontana, A.; Gerber, S.; Giammarchi, M.; Gligorova, A.; Guatieri, F.; Haider, S.; Hinterberger, A.; Holmestad, H.; Kellerbauer, A.; Krasnický, D.; Lagomarsino, V.; Lansonneur, P.; Lebrun, P.; Malbrunot, C.; Mariazzi, S.; Matveev, V.; Mazzotta, Z.; Müller, S. R.; Nebbia, G.; Nedelec, P.; Oberthaler, M.; Pacifico, N.; Pagano, D.; Penasa, L.; Petracek, V.; Povolo, L.; Prelz, F.; Prevedelli, M.; Ravelli, L.; Resch, L.; Rienäcker, B.; Robert, J.; Røhne, O. M.; Rotondi, A.; Sacerdoti, M.; Sandaker, H.; Santoro, R.; Scampoli, P.; Simon, M.; Smestad, L.; Sorrentino, F.; Testera, G.; Tietje, I. C.; Widmann, E.; Yzombard, P.; Zimmer, C.; Zmeskal, J.; Zurlo, N.; Andersen, S. L.; Chevallier, J.; Uggerhøj, U. I.; Lyckegaard, F.

    2017-09-01

    In this work a characterization study of forward emission from a thin, meso-structured silica positron/positronium (Ps) converter following implantation of positrons in light of possible antihydrogen production is presented. The target consisted of a ∼1 μm thick ultraporous silica film e-gun evaporated onto a 20 nm carbon foil. The Ps formation and emission was studied via Single Shot Positron Annihilation Lifetime Spectroscopy measurements after implantation of pulses with 3 - 4 ·107 positrons and 10 ns temporal width. The forward emission of implanted positrons and secondary electrons was investigated with a micro-channel plate - phosphor screen assembly, connected either to a CCD camera for imaging of the impinging particles, or to a fast photomultiplier tube to extract information about their time of flight. The maximum Ps formation fraction was estimated to be ∼10%. At least 10% of the positrons implanted with an energy of 3.3 keV are forward-emitted with a scattering angle smaller than 50° and maximum kinetic energy of 1.2 keV. At least 0.1-0.2 secondary electrons per implanted positron were also found to be forward-emitted with a kinetic energy of a few eV. The possible application of this kind of positron/positronium converter for antihydrogen production is discussed.

  12. NMF on positron emission tomography

    DEFF Research Database (Denmark)

    Bödvarsson, Bjarni; Hansen, Lars Kai; Svarer, Claus

    2007-01-01

    In positron emission tomography, kinetic modelling of brain tracer uptake, metabolism or binding requires knowledge of the cerebral input function. Traditionally, this is achieved with arterial blood sampling in the arm or as shown in (Liptrot, M, et al., 2004) by non-invasive K-means clustering....... We propose another method to estimate time-activity curves (TAC) extracted directly from dynamic positron emission tomography (PET) scans by non-negative matrix factorization (NMF). Since the scaling of the basis curves is lost in the NMF the estimated TAC is scaled by a vector alpha which...

  13. Cyclopentanoid analogs of phosphatidylcholine: susceptibility to phospholipase A2.

    Science.gov (United States)

    Lister, M D; Hancock, A J

    1988-10-01

    Six isomers of dipalmitoylcyclopentanetriol phosphocholine (cyclopentano-lecithin) were tested as potential substrates for phospholipase A2. Since each of these analogs possesses a configuration that mimics a narrow range of conformations of a glycerophospholipid molecule, the analogs were used to assess the enzyme's conformational requirements. Studies showed that all of the analogs containing the phosphocholine at the C-1 (or C-3) position could be hydrolyzed, while only one of the three analogs that contains the polar head group at the C-2 position was susceptible. Kinetic studies, however, revealed that only the all-trans-(1,3/2-1P)-cyclopentano-lecithin gave initial rates of hydrolysis that were measurable by pH-stat. Acyl group specificity of the enzyme towards the all-trans isomer was determined with an analog was acyl groups were distinguishable. The synthesis of this mixed-acid-cyclopentano-PC is described herein. When this analog was enzymatically assayed, results unequivocally showed the enzyme to be specific for C-2 acyl hydrolysis. This specificity, and data showing that the all-trans analog is stereospecifically hydrolyzed, indicate that it is acted on in an analogous manner to dipalmitoylphosphatidylcholine. These studies indicate that although the configuration of the analog is not necessarily a prerequisite for hydrolysis, there does appear to be an optimal spatial orientation for enzymatic activity. The analogy between the susceptibilities of all-trans-(1,3/2-1P)-cyclopentano-lecithin and glycero-lecithin suggests that the conformation of the glycero-lecithin during phospholipase A2-mediated hydrolysis may be best simulated by the all-trans orientation of C-O bonds in the artificial substrate.

  14. Design of an intense positron source for linear colliders

    International Nuclear Information System (INIS)

    Ida, H.; Yamada, K.; Funahashi, Y.

    1994-01-01

    The Japan Linear Collider (JLC) requires an intense positron source of 8x10 11 particles per rf-pulse. A computer simulation reveals the possibility of such an intense positron source using 'conventional' technology. In order to relax the limitation of the incident electron energy density due to thermal stress in the converter target, the incident beam radius is enlarged within the range so as not to reduce the positron capture efficiency. A pre-damping ring and beam transport system to the pre-damping ring, which have a large transverse acceptance, play important roles for a high capture efficiency. A prototype positron source has been designed and installed at downstream of 1.54 GeV S-band linac in Accelerator Test Facility (ATF) in order to carry out experiments to develop the essential technology for JLC. The simulated results will be tested in experiments with the prototype positron source. (author)

  15. Search for positron anisotropies in cosmic rays with AMS

    Energy Technology Data Exchange (ETDEWEB)

    Machate, Fabian [1. Physikalisches Institut B, RWTH Aachen University (Germany)

    2016-07-01

    The Alpha Magnetic Spectrometer (AMS-02) on the International Space Station has observed a significant excess of cosmic ray positrons over the background expected from secondary production at energies above 10 GeV. Nearby pulsars and annihilating dark matter particles as a primary source of electrons and positrons have been discussed as an explanation. A possible way of distinguishing between pulsar and dark matter origin is the measurement of dipole anisotropies in the positron flux or the positron to electron ratio. Any anisotropy will be reduced by diffusion in galactic magnetic fields to below the percent level. AMS-02 is the leading space-based experiment for cosmic ray detection and well suited for this search. A new analysis procedure for anisotropies using an event sample with large acceptance is presented. It relies on the ability of the Transition Radiation Detector (TRD) to separate positrons from the proton background.

  16. Variable-energy positron-beam studies of Ni implanted with He

    International Nuclear Information System (INIS)

    Lynn, K.G.; Chen, D.M.; Nielsen, B.; Pareja, R.; Myers, S.

    1986-01-01

    Variable-energy positron-beam studies have been made on well-annealed polycrystalline Ni samples implanted with 30-, 90-, and 180-keV 4 He ions. The positron-annihilation characteristics were measured with a solid-state Ge detector at a number of different incident-positron energies and after isochronal annealing at various temperatures. The Doppler broadening of the annihilation photons was found to be strongly influenced by the 4 He implantations. The data indicate that trapping of the positrons occurred predominantly at small He bubbles. The variation of the broadening with incident-positron energy was sensitive to the depth distribution of the traps. A diffusion model assuming a square concentration-defect profile was developed and analytically fitted to the parametrized momentum data. These fitted results were compared to Monte Carlo range calculations for 4 He in Ni, and fairly good agreement was found. This investigation demonstrates the capabilities of positron annihilation for nondestructive depth profiling in ion-implanted systems. In addition, it establishes parallels between the trapping behavior of positrons and that reported elsewhere for hydrogen, thereby augmenting the present level of understanding of the technologically important trapping of hydrogen by the bubbles

  17. Synthesis and biological evaluation of cyclic analogs of L-carnitine as potential agents in the treatment of myocardial ischemia

    International Nuclear Information System (INIS)

    Woster, P.M.

    1987-01-01

    The purpose of this research was to synthesize a number of cyclic, rigid analogs of L-carnitine, having a variety of predetermined positional and stereochemical orientations, to be used as probes into the spatial and conformational requirements of the enzyme known as carnitine/acylcarnitine translocase. The ability of these analogs to serve as substrates for this enzyme was to be determined by assessing the degree to which they initiate efflux of 14 C-L-carnitine from isolated heart mitochondria. Toward this end, synthesis of several such analogs was attempted, resulting in the isolation and characterization of 9 cyclic analogs of carnitine, 5 of which are previously unreported. Bioevaluation of these synthetic carnitine analogs was conducted in a previously described assay system. Rat heart mitochondria were isolated by differential centrifugation and prepared for the study by incubation with 14 C-L-carnitine. Efflux of radiolabeled carnitine was then monitored in the presence of the compound being evaluated. This represents the first instance in which non-naturally occurring analogs of L-carnitine have been shown to undergo transport via this mitochondrial translocase, suggesting the possibility that cyclic carnitine analogs may find utility as agents in the treatment of myocardial ischemia

  18. Bremsstrahlung pair-production of positrons with low neutron background

    International Nuclear Information System (INIS)

    Lessner, E.

    1998-01-01

    Minimization of component activation is highly desirable at accelerator-based positron sources. Electrons in the 8- to 14-MeV energy range impinging on a target produce photons energetic enough to create electron-positron pairs; however, few of the photons are energetic enough to produce photoneutrons. Slow positron production by low-energy electrons impinging on a multilayer tungsten target with and without electromagnetic extraction between the layers was studied by simulation. The neutron background from 14-MeV electrons is expected to be significantly lower than that encountered with higher-energy electron beams. Numerical results are presented and some ideas for a low-activation slow-positron source are discussed

  19. Muon, positron and antiproton interactions with atoms and molecules

    Energy Technology Data Exchange (ETDEWEB)

    Armour, Edward A G, E-mail: edward.armour@nottingham.ac.u [School of Mathematical Sciences, University of Nottingham, Nottingham NG7 2RD (United Kingdom)

    2010-04-01

    In this paper, a description is given of some interesting processes involving the interaction of a muon, a positron, or an antiproton with atoms and molecules. The process involving a muon is the resonant formation of the muonic molecular ion, dt{mu}, in the muon catalyzed fusion cycle. In the case of a positron, the process considered is positron annihilation in low-energy positron scattering by the hydrogen molecule. The antiproton is considered as the nucleus of an antihydrogen atom interacting with simple atoms. Attention is given to antiproton annihilation through the strong interaction. An outline is given of proposed tests of fundamental physics to be carried out using antihydrogen.

  20. Implantation profile of low-energy positrons in solids

    International Nuclear Information System (INIS)

    Asoka-Kumar, P.; Lynn, K.G.

    1990-01-01

    A simple form for an implantation profile of monoenergetic, low-energy (1--10 keV) positrons in solids is presented. Materials studied include aluminum, copper, molybdenum, palladium, and gold with atomic number ranging from 13 to 79. A simple set of parameters can describe the currently used Makhov profile in slow positron studies of solids. We provide curves and tables for the parameters that can be used to describe the implantation profiles of positrons in any material with atomic number in between 13 and 79

  1. Preliminary results for positron emission mammography: real-time functional breast imaging in a conventional mammography gantry

    International Nuclear Information System (INIS)

    Weinberg, I.; Majewski, S.; Weisenberger, A.; Markowitz, A.; Aloj, L.; Majewski, L,; Danforth, D.; Mulshine, J.; Cowan, K.; Zujewski, J.; Chow, C.; Jones, E.; Chang, V.; Berg, W.; Frank, J.

    1996-01-01

    In order to optimally integrate radiotracer breast imaging within the breast clinic, anatomy and pathology should be easily correlated with functional nuclear medicine breast images. As a first step in the development of a hybrid functional/anatomic breast imaging platform with biopsy capability, a conventional X-ray mammography gantry was modified to image the compressed brest with positron emitters. Phantom studies with the positron emission mammography (PEM) device showed that a 1-cc hot spot could be detected within 5 min. A preliminary clinical trial demonstrated in vivo visualization of primary breast cancer within 4 min. For sites where positron-emitting radionuclides are available, PEM promises to achieve low-cost directed functional examination of breast abnormalities, with potential for achieving X-ray correlation and image-guided biopsy. (orig.)

  2. Positron cross-field transport due to quasibound states of antihydrogen

    International Nuclear Information System (INIS)

    Ahat, Y.; Correa, C.E.; Ordonez, C.A.

    2007-01-01

    Within the past few years, experiments have been reported in which antiprotons produced at the CERN Antiproton Decelerator facility were slowed, trapped in nested Penning traps and made to interact with a positron plasma such that antihydrogen was formed. Classical trajectory simulations of the interactions between the antiprotons and positrons have been reported to indicate that positive-energy, quasibound states of antihydrogen can form at a rate that exceeds the rate of formation of stable Rydberg states. The formation of quasibound states may affect the rate of diffusion of positrons across the magnetic field that confines them in the nested Penning trap. Simulations indicate that a binary interaction associated with the formation and disintegration of a quasibound state can cause a shift of the positron's guiding center that is much larger than the positron cyclotron radius before the interaction. A theory is presented that describes positron cross-magnetic-field diffusion due to quasibound states of antihydrogen

  3. Basic principles of 18F-fluoro-deoxyglucose positron emission tomography

    International Nuclear Information System (INIS)

    Standke, R.

    2002-01-01

    Positron emission tomography uses photons to receive regional information about dynamic, physiologic, and biochemical processes in the living body. A positron decay is measured indirectly by the simultaneous registration of both gamma rays created by the annihilation. The event is counted, if two directly opposite located detectors register gamma rays in coincidence. Unfortunately the detectors of a positron emission tomography system do not register only true coincident events. There are also scattered and random coincidences. Different types of positron tomographs are presented and scintillation crystals, which are in use for positron emission tomography are discussed. The 2D- and 3D-acquisition methods are described as well as preprocessing methods, such as correction for attenuation, scatter and dead time. For quantification the relative parameter standard uptake value (SUV) is explained. Finally hybrid systems, such as combined positron emission tomography/computed tomography scanners and the use of computed tomography data for attenuation correction are introduced. (author)

  4. Positron study of negative charge states in order-disorder ferroelectrics

    Energy Technology Data Exchange (ETDEWEB)

    Troev, T.; Berovsky, K.; Peneva, S. [Bulgarian Academy of Sciences, Sofia (Bulgaria). Inst. for Nuclear Research and Nuclear Energy

    2001-07-01

    The positive positron charge opens the possibility for determining the changes in charge states in technologically important order-disorder ferroelectrics. Here we show that dipole polarization disordering within domains affects the positron annihilation mechanism. The positron lifetime parameters in triglycine sulphate (TGS) (NH{sub 3}CH{sub 2}COOH){sub 3}H{sub 2}SO{sub 4}, Rochelle salt (RS) NaKC{sub 4}H{sub 4}O{sub 6}.4H{sub 2}O and Potassium dihydrogen phosphate (KDP) KH{sub 2}PO{sub 4}, at different temperatures and gamma-irradiation doses depend on the charge point defects. The increase of the positron long lifetime component {tau}{sub 2} is proportional to the temperature and gamma-irradiation dose. In gamma irradiated TGS positrons are trapped in defect electron states of oxigen ions of two radicals CH{sub 2}COO{sup -} and NH{sub 3}CHCOO{sup -}. In RS positrons are trapped also in defect electron states of oxygen ions and OH groups. (orig.)

  5. Words, Concepts, and the Geometry of Analogy

    Directory of Open Access Journals (Sweden)

    Stephen McGregor

    2016-08-01

    Full Text Available This paper presents a geometric approach to the problem of modelling the relationship between words and concepts, focusing in particular on analogical phenomena in language and cognition. Grounded in recent theories regarding geometric conceptual spaces, we begin with an analysis of existing static distributional semantic models and move on to an exploration of a dynamic approach to using high dimensional spaces of word meaning to project subspaces where analogies can potentially be solved in an online, contextualised way. The crucial element of this analysis is the positioning of statistics in a geometric environment replete with opportunities for interpretation.

  6. Terrestrial Spaceflight Analogs: Antarctica

    Science.gov (United States)

    Crucian, Brian

    2013-01-01

    Alterations in immune cell distribution and function, circadian misalignment, stress and latent viral reactivation appear to persist during Antarctic winterover at Concordia Station. Some of these changes are similar to those observed in Astronauts, either during or immediately following spaceflight. Others are unique to the Concordia analog. Based on some initial immune data and environmental conditions, Concordia winterover may be an appropriate analog for some flight-associated immune system changes and mission stress effects. An ongoing smaller control study at Neumayer III will address the influence of the hypoxic variable. Changes were observed in the peripheral blood leukocyte distribution consistent with immune mobilization, and similar to those observed during spaceflight. Alterations in cytokine production profiles were observed during winterover that are distinct from those observed during spaceflight, but potentially consistent with those observed during persistent hypobaric hypoxia. The reactivation of latent herpesviruses was observed during overwinter/isolation, that is consistently associated with dysregulation in immune function.

  7. Evidence of shallow positron traps in ion-implanted InP observed by maximum entropy reconstruction of positron lifetime distribution: a test of MELT

    International Nuclear Information System (INIS)

    Chen, Z.Q.; Wang, S.J.

    1999-01-01

    A newly developed maximum entropy method, which was realized by the computer program MELT introduced by Shukla et al., was used to analyze positron lifetime spectra measured in semiconductors. Several simulation studies were done to test the performance of this algorithm. Reliable reconstruction of positron lifetime distributions can be extracted at relatively lower counts, which shows the applicability and superiority of this method. Two positron lifetime spectra measured in ion-implanted p-InP(Zn) at 140 and 280 K, respectively were analyzed by this program. The lifetime distribution differed greatly for the two temperatures, giving direct evidence of the existence of shallow positron traps at low temperature

  8. Present status of positron factory project

    International Nuclear Information System (INIS)

    Okada, S.; Sunaga, H.; Kaneko, H.; Tachibana, H.; Yotsumoto, K.; Okamoto, J.

    1992-01-01

    The Japan Atomic Energy Research Institute, JAERI, has been promoting design studies for the 'Positron Factory', in which linac-based intense monoenergetic positron beams are planned to be applied to advanced materials characterization and new fields of basic research. A tentative goal of the beam intensity is 10 10 s -1 , which is assumed to be realized with an electron linac of 100 kW class with a beam energy around 100 to 150 MeV. We performed a technical survey on the dedicated linac. It confirmed technical feasibility of manufacturing the state-of-the-art machine. We have been carrying out a design study of the target. A new concept of the target design is proposed, which is expected to supply intense slow positron beams simultaneously for multiple beam channels, on the basis of Monte Carlo simulations. (author)

  9. Measurement of the positron polarization at an helical undulator based positron source for the international linear collider ILC. The E-166 experiment at SLAC

    Energy Technology Data Exchange (ETDEWEB)

    Karim, Laihem

    2008-06-05

    A helical undulator based polarized positron source is forseen at a future International Linear Collider (ILC). The E-166 experiment has tested this scheme using a one meter long, short-period, pulsed helical undulator installed in the Final Focus Test Beam (FFTB) at SLAC. A low-emittance 46.6 GeV electron beam passing through this undulator generated circularly polarized photons with energies up to about 8 MeV. The generated photons of several MeV with circular polarization are then converted in a relatively thin target to generate longitudinally polarized positrons. Measurements of the positron polarization have been performed at 5 different energies of the positrons. In addition electron polarization has been determined for one energy point. For a comparison of the measured asymmetries with the expectations detailed simulations were necessary. This required upgrading GEANT4 to include the dominant polarization dependent interactions of electrons, positrons and photons in matter. The measured polarization of the positrons agrees with the expectations and is for the energy point with the highest polarization at 6MeV about 80%. (orig.)

  10. Positron deep-level transient spectroscopy in semi-insulating-GaAs using the positron velocity transient method

    International Nuclear Information System (INIS)

    Tsia, M.; Fung, S.; Beling, C.D.

    2001-01-01

    Recently a new semiconductor defect spectroscopy, namely positron deep level transient spectroscopy (PDLTS) has been proposed that combines the energy selectivity of deep level transient spectroscopy with the structural sensitivity of positron annihilation spectroscopy. This paper focuses on one variant of PDLTS, namely positron velocity PDLTS, which has no sensitivity towards vacancy defects but nevertheless is useful in studying deep levels in semi-insulators. In the present study the electric field within the depletion region of semi-insulating GaAs is monitored through the measurement of the small Doppler shift in the annihilation radiation that comes from this region as a result of positron drift. The drift is the result of an increasing electric field produced by space charge building up from ionizing deep level defects. Doppler shift transients are measured between 50-300 K. The EL2 level emission transients are clearly seen at temperatures around 300 K that yield E C -0.78±0.08eV for the energy of EL2. The EL2 electron capture rate is found to have an activation energy of 0.61±0.08eV which most probably arises from freeze out of conduction electrons. We find the surprising result that emission and capture transients can be seen at temperatures below 200 K. Possible reasons for these transients are discussed. (orig.)

  11. Water-sensitive positron trapping modes in nanoporous magnesium aluminate ceramics

    International Nuclear Information System (INIS)

    Filipecki, J; Ingram, A; Klym, H; Shpotyuk, O; Vakiv, M

    2007-01-01

    The water-sensitive positron trapping modes in nanoporous MgAl 2 O 4 ceramics with a spinel structure are studied. It is shown that water-sorption processes in magnesium aluminate ceramics leads to corresponding increase in positron trapping rates of extended defects located near intergranual boundaries. This catalytic affect has reversible nature, being strongly dependent on sorption water fluxes in ceramics. The fixation of all water-dependent positron trapping inputs allow to refine the most significant changes in positron trapping rate of extended defects

  12. Water-sensitive positron trapping modes in nanoporous magnesium aluminate ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Filipecki, J [Institute of Physics of Jan Dlugosz University, 13/15, al. Armii Krajowej, Czestochowa, PL 42201 (Poland); Ingram, A [Opole University of Technology, 75, Ozimska str., Opole, PL 45370 (Poland); Klym, H [Institute of Materials of SRC ' Carat' , 202, Stryjska str., Lviv, UA 79031 (Ukraine); Shpotyuk, O [Institute of Materials of SRC ' Carat' , 202, Stryjska str., Lviv, UA 79031 (Ukraine); Vakiv, M [Institute of Materials of SRC ' Carat' , 202, Stryjska str., Lviv, UA 79031 (Ukraine)

    2007-08-15

    The water-sensitive positron trapping modes in nanoporous MgAl{sub 2}O{sub 4} ceramics with a spinel structure are studied. It is shown that water-sorption processes in magnesium aluminate ceramics leads to corresponding increase in positron trapping rates of extended defects located near intergranual boundaries. This catalytic affect has reversible nature, being strongly dependent on sorption water fluxes in ceramics. The fixation of all water-dependent positron trapping inputs allow to refine the most significant changes in positron trapping rate of extended defects.

  13. Electron-positron plasma generation in a pulsar magnetosphere

    International Nuclear Information System (INIS)

    Gurevich, A.V.; Istomin, Ya.N.

    1985-01-01

    The generation of an electron-positron plasma in vacuum (vacuum ''breakdown'') in the presence of an inhomogeneous electric field and strong curvilinear magnetic field is considered. A situation of this type may occur in the magnetosphere of a rotating neutron star. A general set of kinetic equations for electrons, positrons and γ quanta in a curvilinear magnetic field is derived by taking into account electron-positron pair production and emission of curvicur and synchrotron photons. The conditions for appearance of ''breakdown'' are determined and the threshold value of the elec tric field discontinuity at the surface of the star is found. Multiplication of particles in the magnetosphere is investigated and the electron, positron and γ quantum distribution functions are found. The extinction limit of pulsars is determined. The theory is shown to be in accordance with the observation results

  14. Concerning the trapping of positrons in ionic solids

    International Nuclear Information System (INIS)

    Kunz, A.B.; Waber, J.T.

    1982-01-01

    The total energy of several ionic crystals which contain lattice defects plus a positron were studied in the Hartree-Fock limit. Large uncontracted basis sets of GTO's were used to ensure binding if it would occur. Specifically, the attraction of a positron to a cation vacancy was sought for alkali halides as well as for nickel oxide. While the binding energy to nickel oxide was 8.1 eV, there was very little tendency for the positron to be trapped in the alkali halides. The trapping at a Vsub(k) site was also investigated using similar restricted HF approximation with large sets of GTO's. This defect in LiF was shown to be stable by 0.73 eV, by itself but was unable to bind a positron. These two results are not compatible with qPs being localized in such crystals. (Auth.)

  15. Structured Analog CMOS Design

    CERN Document Server

    Stefanovic, Danica

    2008-01-01

    Structured Analog CMOS Design describes a structured analog design approach that makes it possible to simplify complex analog design problems and develop a design strategy that can be used for the design of large number of analog cells. It intentionally avoids treating the analog design as a mathematical problem, developing a design procedure based on the understanding of device physics and approximations that give insight into parameter interdependences. The proposed transistor-level design procedure is based on the EKV modeling approach and relies on the device inversion level as a fundament

  16. Analog and hybrid computing

    CERN Document Server

    Hyndman, D E

    2013-01-01

    Analog and Hybrid Computing focuses on the operations of analog and hybrid computers. The book first outlines the history of computing devices that influenced the creation of analog and digital computers. The types of problems to be solved on computers, computing systems, and digital computers are discussed. The text looks at the theory and operation of electronic analog computers, including linear and non-linear computing units and use of analog computers as operational amplifiers. The monograph examines the preparation of problems to be deciphered on computers. Flow diagrams, methods of ampl

  17. Precision analog signal processor for beam position measurements in electron storage rings

    International Nuclear Information System (INIS)

    Hinkson, J.A.; Unser, K.B.

    1995-01-01

    Beam position monitors (BPM) in electron and positron storage rings have evolved from simple systems composed of beam pickups, coaxial cables, multiplexing relays, and a single receiver (usually a analyzer) into very complex and costly systems of multiple receivers and processors. The older may have taken minutes to measure the circulating beam closed orbit. Today instrumentation designers are required to provide high-speed measurements of the beam orbit, often at the ring revolution frequency. In addition the instruments must have very high accuracy and resolution. A BPM has been developed for the Advanced Light Source (ALS) in Berkeley which features high resolution and relatively low cost. The instrument has a single purpose; to measure position of a stable stored beam. Because the pickup signals are multiplexed into a single receiver, and due to its narrow bandwidth, the receiver is not intended for single-turn studies. The receiver delivers normalized measurements of X and Y posit ion entirely by analog means at nominally 1 V/mm. No computers are involved. No software is required. Bergoz, a French company specializing in precision beam instrumentation, integrated the ALS design m their new BPM analog signal processor module. Performance comparisons were made on the ALS. In this paper we report on the architecture and performance of the ALS prototype BPM

  18. Cerebral lesions and event-related potential P300 using positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Sakai, Yasujiro; Okamoto, Kazuma; Tanaka, Makoto; Kondoh, Susumu; Hirai, Shunsaku

    1993-01-01

    To determine what lesions are involved in prolonging event-related potential P300 latency, regional cerebral blood flow (rCBF) and metabolism were investigated by positron emission tomography (PET) in a total of 40 patients with neurologic diseases (12 with chronic cerebrovascular disorder, 9 with spino-cerebellar degeneration, 4 with Alzheimer's type dementia, 4 with amyotrophic lateral sclerosis, and 11 with miscellaneous diseases). There was inverse correlation between rCBF and P300 latency in terms of any of the whole, left, and right hemispheres: P300 latency was associated with decreased rCBF. This was more noticeable in the cerebral cortex than white matter and in the right than left hemisphere, although there was no significant difference between them. In none of the regions, however, was there significant correlation between cerebral oxygen consumption and P300 latency. When the right and left frontal, temporal, parietal and occipital cortexes, thalamus, putamen, and caudatum were examined as regions of interest, there was significantly inverse correlation between rCBF and P300 latency in all regions except for the occipital cortex. This was more noticeable on the right than the left side, although no significant difference was observed. Cerebral oxygen consumption in these lesions did not correlate with P300 latency. In the study on bilateral rCBF difference, decreased rCBF confined to the right parietal lobe, bilateral thalamus and bilateral temporal lobes was found to be associated with a significantly prolonged P300 latency. Thus, rCBF in these regions seemed to be particularly responsible for P300 latency. (N.K.)

  19. Cerebral lesions and event-related potential P300 using positron emission tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Yasujiro; Okamoto, Kazuma; Tanaka, Makoto; Kondoh, Susumu; Hirai, Shunsaku (Gunma Univ., Maebashi (Japan). School of Medicine)

    1993-06-01

    To determine what lesions are involved in prolonging event-related potential P300 latency, regional cerebral blood flow (rCBF) and metabolism were investigated by positron emission tomography (PET) in a total of 40 patients with neurologic diseases (12 with chronic cerebrovascular disorder, 9 with spino-cerebellar degeneration, 4 with Alzheimer's type dementia, 4 with amyotrophic lateral sclerosis, and 11 with miscellaneous diseases). There was inverse correlation between rCBF and P300 latency in terms of any of the whole, left, and right hemispheres: P300 latency was associated with decreased rCBF. This was more noticeable in the cerebral cortex than white matter and in the right than left hemisphere, although there was no significant difference between them. In none of the regions, however, was there significant correlation between cerebral oxygen consumption and P300 latency. When the right and left frontal, temporal, parietal and occipital cortexes, thalamus, putamen, and caudatum were examined as regions of interest, there was significantly inverse correlation between rCBF and P300 latency in all regions except for the occipital cortex. This was more noticeable on the right than the left side, although no significant difference was observed. Cerebral oxygen consumption in these lesions did not correlate with P300 latency. In the study on bilateral rCBF difference, decreased rCBF confined to the right parietal lobe, bilateral thalamus and bilateral temporal lobes was found to be associated with a significantly prolonged P300 latency. Thus, rCBF in these regions seemed to be particularly responsible for P300 latency. (N.K.).

  20. Plasma manipulation techniques for positron storage in a multicell trap

    International Nuclear Information System (INIS)

    Danielson, J. R.; Weber, T. R.; Surko, C. M.

    2006-01-01

    New plasma manipulation techniques are described that are central to the development of a multicell Penning trap designed to increase positron storage by orders of magnitude (e.g., to particle numbers N≥10 12 ). The experiments are done using test electron plasmas. A technique is described to move plasmas across the confining magnetic field and to deposit them at specific radial and azimuthal positions. Techniques to fill and operate two in-line plasma cells simultaneously, and the use of 1 kV confinement potentials are demonstrated. These experiments establish the capabilities to create, confine, and manipulate plasmas with the parameters required for a multicell trap; namely, particle numbers >10 10 in a single cell with plasma temperature ≤0.2 eV for plasma lengths ∼10 cm and radii ≤0.2 cm. The updated design of a multicell positron trap for 10 12 particles is described