WorldWideScience

Sample records for amplified ligation selected

  1. ALIS-FLP: Amplified ligation selected fragment-length polymorphism method for microbial genotyping

    DEFF Research Database (Denmark)

    Brillowska-Dabrowska, A.; Wianecka, M.; Dabrowski, Slawomir

    2008-01-01

    A DNA fingerprinting method known as ALIS-FLP (amplified ligation selected fragment-length polymorphism) has been developed for selective and specific amplification of restriction fragments from TspRI restriction endonuclease digested genomic DNA. The method is similar to AFLP, but differs...

  2. A label-free electrochemiluminescent sensor for ATP detection based on ATP-dependent ligation.

    Science.gov (United States)

    Zhao, Tingting; Lin, Chunshui; Yao, Qiuhong; Chen, Xi

    2016-07-01

    In this work, we describe a new label-free, sensitive and highly selective strategy for the electrochemiluminescent (ECL) detection of ATP at the picomolar level via ATP-induced ligation. The molecular-beacon like DNA probes (P12 complex) are self-assembled on a gold electrode. The presence of ATP leads to the ligation of P12 complex which blocks the digestion by Exonuclease III (Exo III). The protected P12 complex causes the intercalation of numerous ECL indicators (Ru(phen)3(2+)) into the duplex DNA grooves, resulting in significantly amplified ECL signal output. Since the ligating site of T4 DNA ligase and the nicking site of Exo III are the same, it involves no long time of incubation for conformation change. The proposed strategy combines the amplification power of enzyme and the inherent high sensitivity of the ECL technique and enables picomolar detection of ATP. The developed strategy also shows high selectivity against ATP analogs, which makes our new label-free and highly sensitive ligation-based method a useful addition to the amplified ATP detection arena. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Comparison and transfer testing of multiplex ligation detection methods for GM plants

    Directory of Open Access Journals (Sweden)

    Ujhelyi Gabriella

    2012-01-01

    Full Text Available Abstract Background With the increasing number of GMOs on the global market the maintenance of European GMO regulations is becoming more complex. For the analysis of a single food or feed sample it is necessary to assess the sample for the presence of many GMO-targets simultaneously at a sensitive level. Several methods have been published regarding DNA-based multidetection. Multiplex ligation detection methods have been described that use the same basic approach: i hybridisation and ligation of specific probes, ii amplification of the ligated probes and iii detection and identification of the amplified products. Despite they all have this same basis, the published ligation methods differ radically. The present study investigated with real-time PCR whether these different ligation methods have any influence on the performance of the probes. Sensitivity and the specificity of the padlock probes (PLPs with the ligation protocol with the best performance were also tested and the selected method was initially validated in a laboratory exchange study. Results Of the ligation protocols tested in this study, the best results were obtained with the PPLMD I and PPLMD II protocols and no consistent differences between these two protocols were observed. Both protocols are based on padlock probe ligation combined with microarray detection. Twenty PLPs were tested for specificity and the best probes were subjected to further evaluation. Up to 13 targets were detected specifically and simultaneously. During the interlaboratory exchange study similar results were achieved by the two participating institutes (NIB, Slovenia, and RIKILT, the Netherlands. Conclusions From the comparison of ligation protocols it can be concluded that two protocols perform equally well on the basis of the selected set of PLPs. Using the most ideal parameters the multiplicity of one of the methods was tested and 13 targets were successfully and specifically detected. In the

  4. Precise Sequential DNA Ligation on A Solid Substrate: Solid-Based Rapid Sequential Ligation of Multiple DNA Molecules

    Science.gov (United States)

    Takita, Eiji; Kohda, Katsunori; Tomatsu, Hajime; Hanano, Shigeru; Moriya, Kanami; Hosouchi, Tsutomu; Sakurai, Nozomu; Suzuki, Hideyuki; Shinmyo, Atsuhiko; Shibata, Daisuke

    2013-01-01

    Ligation, the joining of DNA fragments, is a fundamental procedure in molecular cloning and is indispensable to the production of genetically modified organisms that can be used for basic research, the applied biosciences, or both. Given that many genes cooperate in various pathways, incorporating multiple gene cassettes in tandem in a transgenic DNA construct for the purpose of genetic modification is often necessary when generating organisms that produce multiple foreign gene products. Here, we describe a novel method, designated PRESSO (precise sequential DNA ligation on a solid substrate), for the tandem ligation of multiple DNA fragments. We amplified donor DNA fragments with non-palindromic ends, and ligated the fragment to acceptor DNA fragments on solid beads. After the final donor DNA fragments, which included vector sequences, were joined to the construct that contained the array of fragments, the ligation product (the construct) was thereby released from the beads via digestion with a rare-cut meganuclease; the freed linear construct was circularized via an intra-molecular ligation. PRESSO allowed us to rapidly and efficiently join multiple genes in an optimized order and orientation. This method can overcome many technical challenges in functional genomics during the post-sequencing generation. PMID:23897972

  5. Template-directed ligation of tethered mononucleotides by t4 DNA ligase for kinase ribozyme selection.

    Directory of Open Access Journals (Sweden)

    David G Nickens

    Full Text Available BACKGROUND: In vitro selection of kinase ribozymes for small molecule metabolites, such as free nucleosides, will require partition systems that discriminate active from inactive RNA species. While nucleic acid catalysis of phosphoryl transfer is well established for phosphorylation of 5' or 2' OH of oligonucleotide substrates, phosphorylation of diffusible small molecules has not been demonstrated. METHODOLOGY/PRINCIPAL FINDINGS: This study demonstrates the ability of T4 DNA ligase to capture RNA strands in which a tethered monodeoxynucleoside has acquired a 5' phosphate. The ligation reaction therefore mimics the partition step of a selection for nucleoside kinase (deoxyribozymes. Ligation with tethered substrates was considerably slower than with nicked, fully duplex DNA, even though the deoxynucleotides at the ligation junction were Watson-Crick base paired in the tethered substrate. Ligation increased markedly when the bridging template strand contained unpaired spacer nucleotides across from the flexible tether, according to the trends: A(2>A(1>A(3>A(4>A(0>A(6>A(8>A(10 and T(2>T(3>T(4>T(6 approximately T(1>T(8>T(10. Bridging T's generally gave higher yield of ligated product than bridging A's. ATP concentrations above 33 microM accumulated adenylated intermediate and decreased yields of the gap-sealed product, likely due to re-adenylation of dissociated enzyme. Under optimized conditions, T4 DNA ligase efficiently (>90% joined a correctly paired, or TratioG wobble-paired, substrate on the 3' side of the ligation junction while discriminating approximately 100-fold against most mispaired substrates. Tethered dC and dG gave the highest ligation rates and yields, followed by tethered deoxyinosine (dI and dT, with the slowest reactions for tethered dA. The same kinetic trends were observed in ligase-mediated capture in complex reaction mixtures with multiple substrates. The "universal" analog 5-nitroindole (dNI did not support ligation when

  6. Change of hepatic volume after selective bile duct ligation: an experimental study in the rabbit

    International Nuclear Information System (INIS)

    Lee, Hye Won; Yoon, Yup; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won; Oh, Joo Hyeong; Rim, Hyeong Teck; Kim, Youn Wha; Lee, Seok Hwan

    1998-01-01

    To evaluate the role of bile duct obstuction in the development of atrophy of the liver, using an animal model. Seven rabbits were divided into two groups: group 1(n=3D5), in which there was selective bile duct ligation, and group 2(n=3D2), which underwent a sham operation. Each group was evaluated using CT for changes in hepatic volume after selective bile duct ligation or a sham operation. In group I, the diameter of dilated bile duct was measured 2, 4, 8, 12 and 16 weeks after bile duct ligation, while gross and histologic change were evaluated in all cases. In group 1, bile duct dilatation was seen on CT two weeks after selective bile duct ligation, and did not change significantly during follow-up. In four of five cases, CT revealed no evidence of significant atrophy of the involved segment. Pathologic specimens, however, revealed dilatation of the bile duct, periductal fibrosis, infiltration of chronic inflammatory cells, and periportal fibrosis. One of five cases showed segmental liver atrophy after selective bile duct ligation. In addion to the above pathologic findings, there was obstruction of the portal vein by foreign body reaction. In group 2, no evidence of dilated bile duct or liver atrophy was revealed by CT or pathologic specimen after a sham operation. During long-term follow-up of 16 weeks, obstruction of the bile duct did not play a major role in the development of lobar atrophy in the rabbit.=20

  7. Selective desulfurization of cysteine in the presence of Cys(Acm) in polypeptides obtained by native chemical ligation.

    Science.gov (United States)

    Pentelute, Brad L; Kent, Stephen B H

    2007-02-15

    Increased versatility for the synthesis of proteins and peptides by native chemical ligation requires the ability to ligate at positions other than Cys. Here, we report that Raney nickel can be used under standard conditions for the selective desulfurization of Cys in the presence of Cys(Acm). This simple and practical tactic enables the more common Xaa-Ala junctions to be used as ligation sites for the chemical synthesis of Cys-containing peptides and proteins. [reaction: see text].

  8. Is there a role for amplifiers in sexual selection?

    Science.gov (United States)

    Gualla, Filippo; Cermelli, Paolo; Castellano, Sergio

    2008-05-21

    The amplifier hypothesis states that selection could favour the evolution of traits in signallers that improve the ability of receivers to extract honest information from other signals or cues. We provide a formal definition of amplifiers based on the receiver's mechanisms of signal perception and we present a game-theoretical model in which males advertise their quality and females use sequential-sampling tactics to choose among prospective mates. The main effect of an amplifier on the female mating strategy is to increase her mating threshold, making the female more selective as the effectiveness of the amplifier increases. The effects of the amplifier on male advertising strategy depends both on the context and on the types of the amplifier involved. We consider two different contexts for the evolution of amplifiers (when the effect of amplifiers is on signals and when it is on cues) and two types of amplifiers (the 'neutral amplifier', when it improves quality assessment without altering male attractiveness, and the 'attractive amplifier', when it improves both quality assessment and male attractiveness). The game-theoretical model provides two main results. First, neutral and attractive amplifiers represent, respectively, a conditional and an unconditional signalling strategy. In fact, at the equilibrium, neutral amplifiers are displayed only by males whose advertising level lays above the female acceptance threshold, whereas attractive amplifiers are displayed by all signalling males, independent of their quality. Second, amplifiers of signals increase the differences in advertising levels between amplifying and not-amplifying males, but they decrease the differences within each group, so that the system converges towards an 'all-or-nothing' signalling strategy. By applying concepts from information theory, we show that the increase in information transfer at the perception level due to the amplifier of signals is contrasted by a decrease in information

  9. Ligation-mediated PCR with a back-to-back adapter reduces amplification bias resulting from variations in GC content.

    Science.gov (United States)

    Ishihara, Satoru; Kotomura, Naoe; Yamamoto, Naoki; Ochiai, Hiroshi

    2017-08-15

    Ligation-mediated polymerase chain reaction (LM-PCR) is a common technique for amplification of a pool of DNA fragments. Here, a double-stranded oligonucleotide consisting of two primer sequences in back-to-back orientation was designed as an adapter for LM-PCR. When DNA fragments were ligated with this adapter, the fragments were sandwiched between two adapters in random orientations. In the ensuing PCR, ligation products linked at each end to an opposite side of the adapter, i.e. to a distinct primer sequence, were preferentially amplified compared with products linked at each end to an identical primer sequence. The use of this adapter in LM-PCR reduced the impairment of PCR by substrate DNA with a high GC content, compared with the use of traditional LM-PCR adapters. This result suggested that our method has the potential to contribute to reduction of the amplification bias that is caused by an intrinsic property of the sequence context in substrate DNA. A DNA preparation obtained from a chromatin immunoprecipitation assay using pulldown of a specific form of histone H3 was successfully amplified using the modified LM-PCR, and the amplified products could be used as probes in a fluorescence in situ hybridization analysis. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Enzyme Treatment-Free and Ligation-Independent Cloning Using Caged Primers in Polymerase Chain Reactions

    Directory of Open Access Journals (Sweden)

    Akinori Kuzuya

    2011-12-01

    Full Text Available A new simple scheme for constructing recombinant vectors that does not require any restriction enzyme, ligase, or any other special enzyme treatment has been developed. By using caged primers in PCR, unnatural sticky-ends of any sequence, which are sufficiently long for ligation-independent cloning (LIC, are directly prepared on the product after a brief UVA irradiation. Target genes and vectors amplified by this light-assisted cohesive-ending (LACE PCR join together in the desired arrangement in a simple mixture of them, tightly enough to be repaired and ligated in competent cells.

  11. Development of a modified model of spinal cord ischemia injury by selective ligation of lumbar arteries in rabbits.

    Science.gov (United States)

    Xiao, W; Wen, J; Huang, Y-C; Yu, B-S

    2017-11-01

    Experimental study. The aim of this study is to develop a modified model of spinal cord ischemia in rabbits. Shenzhen Key Laboratory of Spine Surgery, Shenzhen, China. In total, 20 New Zealand rabbits were divided into the following four groups according to the level of ligation of bilateral lumbar arteries: (1) group A, sham group, no ligation, n=5; (2) group B, ligation of bilateral lumbar arteries at three levels (L2-L4, n=5); (3) group C, ligation of bilateral lumbar arteries at four levels (L2-L5, n=5); and (4) group D, ligation of bilateral lumbar arteries at five levels (L1-L5, n=5). The latency of motor-evoked potentials was measured intraoperatively and the modified Tarlov grades were scored, followed by a histological observation of spinal cord, on the seventh day after surgery. All 10 rabbits in Group A and Group B were electrophysiologically, neurologically and histologically normal. In Group C, moderate spinal cord ischemia injury was found in three of five rabbits: they had prolonged latency of motor-evoked potentials and neuronal karyopyknosis in the anterior horn of spinal cord, and the average Tarlov score was 4.2±0.8. In Group D, severe spinal cord ischemia injury was recorded in all the five rabbits: the latency of motor-evoked potential prolonged in one rabbit, whereas the waveform disappeared in four rabbits; loss of neurons and vacuolation of gray matter were seen in spinal cord sections, and the average Tarlov score was 0.6±0.9. Selective ligation of lumbar arteries was a modified method to induce feasible and reproducible model of spinal cord ischemia in rabbits.

  12. Chemoselective ligation and antigen vectorization.

    Science.gov (United States)

    Gras-Masse, H

    2001-01-01

    The interest in cocktail-lipopeptide vaccines has now been confirmed by phase I clinical trials: highly diversified B-, T-helper or cytotoxic T-cell epitopes can be combined with a lipophilic vector for the induction of B- and T-cell responses of predetermined specificity. With the goal of producing an improved vaccine that should ideally induce a multispecific response in non-selected populations, increasing the diversity of the immunizing mixture represents one of the most obvious strategies.The selective delivery of antigens to professional antigen-presenting cells represents another promising approach for the improvement of vaccine efficacy. In this context, the mannose-receptor represents an attractive entry point for the targeting to dendritic cells of antigens linked to clustered glycosides or glycomimetics. In all cases, highly complex but fully characterized molecules must be produced. To develop a modular and flexible strategy which could be generally applicable to a large set of peptide antigens, we elected to explore the potentialities of chemoselective ligation methods. The hydrazone bond was found particularly reliable and fully compatible with sulphide ligation. Hydrazone/thioether orthogonal ligation systems could be developed to account for the nature of the antigens and the solubility of the vector systems. Copyright 2001 The International Association for Biologicals.

  13. Operational amplifiers

    CERN Document Server

    Dostal, Jiri

    1993-01-01

    This book provides the reader with the practical knowledge necessary to select and use operational amplifier devices. It presents an extensive treatment of applications and a practically oriented, unified theory of operational circuits.Provides the reader with practical knowledge necessary to select and use operational amplifier devices. Presents an extensive treatment of applications and a practically oriented, unified theory of operational circuits

  14. Chemical Ligation of Folded Recombinant Proteins: Segmental Isotopic Labeling of Domains for NMR Studies

    Science.gov (United States)

    Xu, Rong; Ayers, Brenda; Cowburn, David; Muir, Tom W.

    1999-01-01

    A convenient in vitro chemical ligation strategy has been developed that allows folded recombinant proteins to be joined together. This strategy permits segmental, selective isotopic labeling of the product. The src homology type 3 and 2 domains (SH3 and SH2) of Abelson protein tyrosine kinase, which constitute the regulatory apparatus of the protein, were individually prepared in reactive forms that can be ligated together under normal protein-folding conditions to form a normal peptide bond at the ligation junction. This strategy was used to prepare NMR sample quantities of the Abelson protein tyrosine kinase-SH(32) domain pair, in which only one of the domains was labeled with 15N Mass spectrometry and NMR analyses were used to confirm the structure of the ligated protein, which was also shown to have appropriate ligand-binding properties. The ability to prepare recombinant proteins with selectively labeled segments having a single-site mutation, by using a combination of expression of fusion proteins and chemical ligation in vitro, will increase the size limits for protein structural determination in solution with NMR methods. In vitro chemical ligation of expressed protein domains will also provide a combinatorial approach to the synthesis of linked protein domains.

  15. Torque expression in self-ligating orthodontic brackets and conventionally ligated brackets: A systematic review.

    Science.gov (United States)

    Al-Thomali, Yousef; Mohamed, Roshan-Noor; Basha, Sakeenabi

    2017-01-01

    To evaluate the torque expression of self ligating (SL) orthodontic brackets and conventionally ligated brackets and the torque expression in active and passive SL brackets. Our systematic search included MEDLINE, EMBASE, CINAHL, PsychINFO, Scopus, and key journals and review articles; the date of the last search was April 4th 2016. We graded the methodological quality of the studies by means of the Quality Assessment Tool for Quantitative Studies, developed for the Effective Public Health Practice Project (EPHPP). In total, 87 studies were identified for screening, and 9 studies were eligible. The quality assessment rated one of the study as being of strong quality, 7 (77.78%) of these studies as being of moderate quality. Three out of 7 studies which compared SL and conventionally ligated brackets showed, conventionally ligated brackets with highest torque expression compared to SL brackets. Badawi showed active SL brackets with highest torque expression compared to passive SL brackets. Major and Brauchli showed no significant differences in torque expression of active and passive SL brackets. Conventionally ligated brackets presented with highest torque expression compared to SL brackets. Minor difference was recorded in a torque expression of active and passive SL brackets. Key words: Systematic review, self ligation, torque expression, conventional ligation.

  16. Development of a 11C-labeled tetrazine for rapid tetrazine–trans-cyclooctene ligation

    DEFF Research Database (Denmark)

    Herth, Matthias Manfred; Andersen, Valdemar L.; Lehel, Szabolcs

    2013-01-01

    Tetrazine–trans-cyclooctene ligations are remarkably fast and selective reactions even at low micro-molar concentrations. In bioorthogonal radiochemistry, tools that enable conjugation of radioactive probes to pre-targeted vectors are of great interest. Herein, we describe the successful developm......Tetrazine–trans-cyclooctene ligations are remarkably fast and selective reactions even at low micro-molar concentrations. In bioorthogonal radiochemistry, tools that enable conjugation of radioactive probes to pre-targeted vectors are of great interest. Herein, we describe the successful...

  17. Toward distributed relay selection for opportunistic amplify-and-forward transmission

    KAUST Repository

    Tourki, Kamel

    2011-05-01

    Opportunistic relaying in cooperative communication depends on careful relay selection. However the traditional centralized method used for opportunistic Amplify-and-Forward (OAF) protocols requires precise measurements of channel state information (CSI) at the destination (CSI-OAF). In this paper, we propose a distributed relay selection framework for opportunistic AF (D-OAF) cooperative communications and offer an accurate performance analysis based on exact statistics of the local signalto- noise ratios of the best relay. Furthermore, we validate our analysis by showing that performance simulation results coincide with our analytical results over different network architectures, and we compare our new results with their CSI-based counterparts. © 2011 IEEE.

  18. Therapeutic efficacy of self-ligating brackets: A systematic review.

    Science.gov (United States)

    Dehbi, Hasnaa; Azaroual, Mohamed Faouzi; Zaoui, Fatima; Halimi, Abdelali; Benyahia, Hicham

    2017-09-01

    Over the last few years, the use of self-ligating brackets in orthodontics has progressed considerably. These systems have been the subject of numerous studies with good levels of evidence making it possible to evaluate their efficacy and efficiency compared to conventional brackets. The aim of this study was to evaluate the therapeutic efficacy of self-ligating brackets by means of a systematic review of the scientific literature. A systematic study was undertaken in the form of a recent search of the electronic Pubmed database, oriented by the use of several keywords combined by Boolean operators relating to the therapeutic efficacy of self-ligating brackets through the study of tooth alignment, space closure, expansion, treatment duration and degree of discomfort. The search was limited to randomized controlled studies, and two independent readers identified studies corresponding to the selection criteria. The chosen articles comprised 20 randomized controlled trials. The studies analyzed revealed the absence of significant differences between the two types of system on the basis of the clinical criteria adopted, thereby refuting the hypothesis of the superiority of self-ligating brackets over conventional systems. Copyright © 2017 CEO. Published by Elsevier Masson SAS. All rights reserved.

  19. Dynamic expression of desmin, α-SMA and TGF-β1 during hepatic fibrogenesis induced by selective bile duct ligation in young rats

    Energy Technology Data Exchange (ETDEWEB)

    Gonçalves, J.O.; Tannuri, A.C.A.; Coelho, M.C.M.; Bendit, I.; Tannuri, U. [Laboratório de Pesquisa em Cirurgia Pediátrica (LIM-30), Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil)

    2014-08-15

    We previously described a selective bile duct ligation model to elucidate the process of hepatic fibrogenesis in children with biliary atresia or intrahepatic biliary stenosis. Using this model, we identified changes in the expression of alpha smooth muscle actin (α-SMA) both in the obstructed parenchyma and in the hepatic parenchyma adjacent to the obstruction. However, the expression profiles of desmin and TGF-β1, molecules known to be involved in hepatic fibrogenesis, were unchanged when analyzed by semiquantitative polymerase chain reaction (RT-PCR). Thus, the molecular mechanisms involved in the modulation of liver fibrosis in this experimental model are not fully understood. This study aimed to evaluate the molecular changes in an experimental model of selective bile duct ligation and to compare the gene expression changes observed in RT-PCR and in real-time quantitative PCR (qRT‐PCR). Twenty-eight Wistar rats of both sexes and weaning age (21-23 days old) were used. The rats were separated into groups that were assessed 7 or 60 days after selective biliary duct ligation. The expression of desmin, α-SMA and TGF-β1 was examined in tissue from hepatic parenchyma with biliary obstruction (BO) and in hepatic parenchyma without biliary obstruction (WBO), using RT-PCR and qRT‐PCR. The results obtained in this study using these two methods were significantly different. The BO parenchyma had a more severe fibrogenic reaction, with increased α-SMA and TGF-β1 expression after 7 days. The WBO parenchyma presented a later, fibrotic response, with increased desmin expression 7 days after surgery and increased α-SMA 60 days after surgery. The qRT‐PCR technique was more sensitive to expression changes than the semiquantitative method.

  20. Dynamic expression of desmin, α-SMA and TGF-β1 during hepatic fibrogenesis induced by selective bile duct ligation in young rats

    International Nuclear Information System (INIS)

    Gonçalves, J.O.; Tannuri, A.C.A.; Coelho, M.C.M.; Bendit, I.; Tannuri, U.

    2014-01-01

    We previously described a selective bile duct ligation model to elucidate the process of hepatic fibrogenesis in children with biliary atresia or intrahepatic biliary stenosis. Using this model, we identified changes in the expression of alpha smooth muscle actin (α-SMA) both in the obstructed parenchyma and in the hepatic parenchyma adjacent to the obstruction. However, the expression profiles of desmin and TGF-β1, molecules known to be involved in hepatic fibrogenesis, were unchanged when analyzed by semiquantitative polymerase chain reaction (RT-PCR). Thus, the molecular mechanisms involved in the modulation of liver fibrosis in this experimental model are not fully understood. This study aimed to evaluate the molecular changes in an experimental model of selective bile duct ligation and to compare the gene expression changes observed in RT-PCR and in real-time quantitative PCR (qRT‐PCR). Twenty-eight Wistar rats of both sexes and weaning age (21-23 days old) were used. The rats were separated into groups that were assessed 7 or 60 days after selective biliary duct ligation. The expression of desmin, α-SMA and TGF-β1 was examined in tissue from hepatic parenchyma with biliary obstruction (BO) and in hepatic parenchyma without biliary obstruction (WBO), using RT-PCR and qRT‐PCR. The results obtained in this study using these two methods were significantly different. The BO parenchyma had a more severe fibrogenic reaction, with increased α-SMA and TGF-β1 expression after 7 days. The WBO parenchyma presented a later, fibrotic response, with increased desmin expression 7 days after surgery and increased α-SMA 60 days after surgery. The qRT‐PCR technique was more sensitive to expression changes than the semiquantitative method

  1. An experimental microangiographic study on injured liver acinus by ligation of common bile duct

    International Nuclear Information System (INIS)

    Park, Jong Yeon; Kim, Yoon Gyu; Moon, Ki Ho; Lee, Suek Hong; Kim, Byung Soo; Han, Gun Taik

    1994-01-01

    The purpose of this study was to evaluate the morphologic changes of the injured hepatic acini following ligation of common bile duct and to investigate the pathophysiologic process of hepatic failure and biliary liver cirrhosis in the extrahepatic cholestasis. The common bile ducts of 18 rabbits were ligated partially. The rabbits were killed and selective microangiography was carried out with infusion of barium suspensio via portal vein 4 to 24 weeks after ligation. Selective microangiography was also carried out in two normal rabbits. The microangiographic findings were evaluated and correlated with histopathologic features. The sinusoids of the liver acinus showed distortion, varying degrees of luminal widening, and irregularities in architecture. Terminal branches of the portal vein (TPV) showed increased number of branches, luminal narrowing, tortuosity, distortion, and beaded appearance. Peribiliary plexi were found as thin curvilinear, barium-filled structures along the wall of the dilated bile duct. The microangiographic findings were well correlated with histopathologic findings. The grades of microangiographic and histopathologic findings were poorly correlated with the duration of the ligation of CBD. Changes in microvasculature of the liver scinus following partial ligation of common bile duct were demonstrated by microangiography. Although the microvascular changes were evoked secondary to the injury, they might have some active roles in the pathophysiologic process in the liver

  2. [Self-ligating edgewise brackets. An overview].

    Science.gov (United States)

    Katsaros, C; Dijkman, J F

    2003-01-01

    During the last years both the manufactures and the orthodontists seem to show an increased interest in self-ligating brackets. This paper aims to present the history of self-ligating systems, to describe the three mostly used bracketsystems and to review the relevant literature. It seems from the existing data that self-ligating brackets have certain advantages over conventionally ligated brackets. However, the data are still thin and a high need for well designed clinical trials exist.

  3. Orthodontic Bracket Manufacturing Tolerances and Dimensional Differences between Select Self-Ligating Brackets

    Science.gov (United States)

    Major, Thomas W.; Carey, Jason P.; Nobes, David S.; Major, Paul W.

    2010-01-01

    In all manufacturing processes there are tolerances; however, orthodontic bracket manufacturers seldom state the slot dimensional tolerances. This experiment develops a novel method of analyzing slot profile dimensions using photographs of the slot. Five points are selected along each wall, and lines are fitted to define a trapezoidal slot shape. This investigation measures slot height at the slot's top and bottom, angles between walls, slot taper, and the linearity of each wall. Slot dimensions for 30 upper right central incisor self-ligating stainless steel brackets from three manufacturers were evaluated. Speed brackets have a slot height 2% smaller than the nominal 0.559 mm size and have a slightly convergent taper. In-Ovation brackets have a divergent taper at an average angle of 1.47 degrees. In-Ovation is closest to the nominal value of slot height at the slot base and has the smallest manufacturing tolerances. Damon Q brackets are the most rectangular in shape, with nearly 90-degree corners between the slot bottom and walls. Damon slot height is on average 3% oversized. PMID:20981299

  4. Multicomponent Reactions in Ligation and Bioconjugation Chemistry.

    Science.gov (United States)

    Reguera, Leslie; Méndez, Yanira; Humpierre, Ana R; Valdés, Oscar; Rivera, Daniel G

    2018-05-25

    Multicomponent reactions (MCRs) encompass an exciting class of chemical transformations that have proven success in almost all fields of synthetic organic chemistry. These convergent procedures incorporate three or more reactants into a final product in one pot, thus combining high levels of complexity and diversity generation with low synthetic cost. Striking applications of these processes are found in heterocycle, peptidomimetic, and natural product syntheses. However, their potential in the preparation of large macro- and biomolecular constructs has been realized just recently. This Account describes the most relevant results of our group in the utilization of MCRs for ligation/conjugation of biomolecules along with significant contributions from other laboratories that validate the utility of this special class of bioconjugation process. Thus, MCRs have proven to be efficient in the ligation of lipids to peptides and oligosaccharides as well as the ligation of steroids, carbohydrates, and fluorescent and affinity tags to peptides and proteins. In the field of glycolipids, we highlight the power of isocyanide-based MCRs with the one-pot double lipidation of glycan fragments functionalized as either the carboxylic acid or amine. In peptide chemistry, the versatility of the multicomponent ligation strategy is demonstrated in both solution-phase lipidation protocols and solid-phase procedures enabling the simultaneous lipidation and biotinylation of peptides. In addition, we show that MCRs are powerful methods for synchronized lipidation/labeling and macrocyclization of peptides, thus accomplishing in one step what usually requires long sequences. In the realm of protein bioconjugation, MCRs have also proven to be effective in labeling, site-selective modification, immobilization, and glycoconjugation processes. For example, we illustrate a successful application of multicomponent polysaccharide-protein conjugation with the preparation of multivalent

  5. Spectrum of menstrual problems after tubal ligation

    International Nuclear Information System (INIS)

    Naqvi, S.S.B.; Akthar, S.; Mubeen, A.; Noor, A.

    2014-01-01

    To determine the frequency of menstrual problems after tubal ligation. Study Design: Descriptive study. Place and Duration of Study: This study was carried out in gynae department of PAF Hospital Sargodha, Pakistan from September 2011 to September 2012. Patients and methods: Two hundred patients were included in the study with menstrual problems after tubal ligation. Results: Forty seven percent of patients presented with menorrhagia, 28% presented with metrorrhagia, 13% patients were having complaints of polymenorrhoea and 5% patients presented with dysmenorrhea and 7% had oligomenorrhoea after tubal ligation. Thirty one percent of patients ended up in hysterectomy and 37% of patients had improvement of symptoms with medical treatment. Conclusion: Menstrual problem is a common complaint in our gyn ecological patients. A large number of these patients had history of tubal ligation. Menorrhagia, metrorrhagia, polymenorrhoea and dysmenorrhoea can occur after tubal ligation. Patients giving the history of menstrual problems and wants tubal ligation should be counselled earlier for these symptoms. (author)

  6. Simplified design of IC amplifiers

    CERN Document Server

    Lenk, John

    1996-01-01

    Simplified Design of IC Amplifiers has something for everyone involved in electronics. No matter what skill level, this book shows how to design and experiment with IC amplifiers. For experimenters, students, and serious hobbyists, this book provides sufficient information to design and build IC amplifier circuits from 'scratch'. For working engineers who design amplifier circuits or select IC amplifiers, the book provides a variety of circuit configurations to make designing easier.Provides basics for all phases of practical design.Covers the most popular forms for amplif

  7. Digital quantification of rolling circle amplified single DNA molecules in a resistive pulse sensing nanopore.

    Science.gov (United States)

    Kühnemund, M; Nilsson, M

    2015-05-15

    Novel portable, sensitive and selective DNA sensor methods for bio-sensing applications are required that can rival conventionally used non-portable and expensive fluorescence-based sensors. In this paper, rolling circle amplification (RCA) products are detected in solution and on magnetic particles using a resistive pulse sensing (RPS) nanopore. Low amounts of DNA molecules are detected by padlock probes which are circularized in a strictly target dependent ligation reaction. The DNA-padlock probe-complex is captured on magnetic particles by sequence specific capture oligonucleotides and amplified by a short RCA. Subsequent RPS analysis is used to identify individual particles with single attached RCA products from blank particles. This proof of concept opens up for a novel non-fluorescent digital DNA quantification method that can have many applications in bio-sensing and diagnostic approaches. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Orchidopexy san ligation technique of orchidopexy

    Directory of Open Access Journals (Sweden)

    Jain Vishal

    2011-01-01

    Full Text Available Pediatric hernia surgery is the most common operation done by pediatric general surgeons and it is a core competency for general surgeons in the developing world. Herniotomy is performed for the surgical repair of hernia and along with orchiopexy for the closure of associated patent processus vaginalis. Traditionally, ligation of hernial sac during orchiopexy is considered mandatory to prevent postoperative development of hernia. The present report was designed to study the results of non-ligation of the hernial sac during orchiopexy. It was found that non-ligation has no untoward effect on early complications and recurrence rate on long-term follow-up. It is suggested that it is not necessary to ligate the hernial sac during orchiopexy in children.

  9. Combining ligation reaction and capillary gel electrophoresis to obtain reliable long DNA probes.

    Science.gov (United States)

    García-Cañas, Virginia; Mondello, Monica; Cifuentes, Alejandro

    2011-05-01

    New DNA amplification methods are continuously developed for sensitive detection and quantification of specific DNA target sequences for, e.g. clinical, environmental or food applications. These new applications often require the use of long DNA oligonucleotides as probes for target sequences hybridization. Depending on the molecular technique, the length of DNA probes ranges from 40 to 450 nucleotides, solid-phase chemical synthesis being the strategy generally used for their production. However, the fidelity of chemical synthesis of DNA decreases for larger DNA probes. Defects in the oligonucleotide sequence result in the loss of hybridization efficiency, affecting the sensitivity and selectivity of the amplification method. In this work, an enzymatic procedure has been developed as an alternative to solid-phase chemical synthesis for the production of long oligonucleotides. The enzymatic procedure for probe production was based on ligation of short DNA sequences. Long DNA probes were obtained from smaller oligonucleotides together with a short sequence that acts as bridge stabilizing the molecular complex for DNA ligation. The ligation reactions were monitored by capillary gel electrophoresis with laser-induced fluorescence detection (CGE-LIF) using a bare fused-silica capillary. The capillary gel electrophoresis-LIF method demonstrated to be very useful and informative for the characterization of the ligation reaction, providing important information about the nature of some impurities, as well as for the fine optimization of the ligation conditions (i.e. ligation cycles, oligonucleotide and enzyme concentration). As a result, the yield and quality of the ligation product were highly improved. The in-lab prepared DNA probes were used in a novel multiplex ligation-dependent genome amplification (MLGA) method for the detection of genetically modified maize in samples. The great possibilities of the whole approach were demonstrated by the specific and sensitive

  10. Experience of rubber band ligation for haemorrhoidal disease

    International Nuclear Information System (INIS)

    Hadi, A.; Aman, Z.; Anwar, F.; Khan, M.; Iqbal, Z.

    2011-01-01

    Objectives: To assess symptomatic relief in haemorrhoidal disease using rubber band ligation. Settings and duration: Surgical unit, Hayatabad Medical Complex, Peshawar from July 2007 to June 2009. Patients and Methods: All patients presenting with rectal bleeding or prolapse underwent proto copy to determine the cause of bleeding. Only patients with first, second and third degree haemorrhoids (bleeding and prolapse) were selected for the study and they underwent rubber band ligation in two sessions, 6 weeks apart. Patients were followed in the OPD at 3 months and one year when their subjective and objective symptoms were noted followed by rectal examination and proctoscopy. Therapeutic response was assessed by symptomatic improvement in bleeding and prolapse of hemorrhoids and any complications. Results: A total of 105 patients underwent rubber band ligation. There were 65(62%) males and 40(38%) females with a male to female ratio of 1.6:1. Age of the patients ranged from 21-65 years (+- 2.4 SD). Twenty three (21.9%) patients had first degree, 50(47.6%) had second degree and 32(30.5%) had third degree haemorrhoids. Forty-eight patients (45.7%) presented with degree, 50(47.6%) had second prolapse, 33(31.4%) had both bleeding and prolapse and 23(21.9%) had bleeding only. At 3 months of follow up rubber band ligation cured 76(72.4%) patients, improved 13(12.4%) and failed in 7(6.7%) patients. At one year follow up, recurrence of bleeding and prolapse occurred in 16(15.2%) patients having third degree haemorrhoids. Overall success was third achieved in 89(84.8%) cases. Complications were seen in 20(19.1%) patients which were of mild to moderate nature and no serious/ life threatening complications were noted. Conclusion: Rubber band legislation is a rapid and safe procedure for testing first, second and and early third degree Conclusions: Rubber band ligation is a rapid and safe non operative procedure for treating first, second and third degree haemorrhoids on out

  11. Banding ligation versus beta-blockers for primary prevention in oesophageal varices in adults

    DEFF Research Database (Denmark)

    Gluud, Lise Lotte; Krag, Aleksander

    2012-01-01

    Non-selective beta-blockers are used as a first-line treatment for primary prevention in patients with medium- to high-risk oesophageal varices. The effect of non-selective beta-blockers on mortality is debated and many patients experience adverse events. Trials on banding ligation versus non...

  12. Artery ligation in the treatment of hemorrhoidal disease

    NARCIS (Netherlands)

    Schuurman, J.P.

    2012-01-01

    The aim of this thesis was to study the working principle in relation to the outcome of the artery ligation procedure; a treatment for hemorrhoidal disease. Hemorrhoidal artery ligation, known as HAL (hemorrhoidal artery ligation) or THD (transanal hemorrhoidal dearterialization) procedure, is a

  13. Effects of selective bile duct ligation on liver parenchyma in young animals: histologic and molecular evaluations.

    Science.gov (United States)

    Tannuri, Ana Cristina A; Coelho, Maria Cecília M; de Oliveira Gonçalves, Josiane; Santos, Maria Mercês; Ferraz da Silva, Luiz Fernando; Bendit, Israel; Tannuri, Uenis

    2012-03-01

    The mechanisms of increased collagen production and liver parenchyma fibrosis are poorly understood. These phenomena are observed mainly in children with biliary obstruction (BO), and in a great number of patients, the evolution to biliary cirrhosis and hepatic failure leads to the need for liver transplantation before adolescence. However, pediatric liver transplantation presents with biliary complications in 20% to 30% of cases in the postoperative period. Intra- or extrahepatic stenosis of bile ducts is frequent and may lead to secondary biliary cirrhosis and the need for retransplantation. It is unknown whether biliary stenosis involving isolated segments or lobes may affect the adjacent nonobstructed lobes by paracrine or endocrine means, leading to fibrosis in this parenchyma. Therefore, the present study aimed to create an experimental model of selective biliary duct ligation in young animals with a subsequent evaluation of the histologic and molecular alterations in liver parenchyma of the obstructed and nonobstructed lobes. After a pilot study to standardize the surgical procedures, weaning rats underwent ligation of the bile ducts of the median, left lateral, and caudate liver lobes. The bile duct of the right lateral lobe was kept intact. To avoid intrahepatic biliary duct collaterals neoformation, the parenchymal connection between the right lateral and median lobes was clamped. The animals were divided into groups according to the time of death: 1, 2, 3, 4, and 8 weeks after surgical procedure. After death, the median and left lateral lobes (with BO) and the right lateral lobe (without BO [NBO]) were harvested separately. A group of 8 healthy nonoperated on animals served as controls. Liver tissues were subjected to histologic evaluation and quantification of the ductular proliferation and of the portal fibrosis. The expressions of smooth muscle α-actin (α-SMA), desmin, and transforming growth factor β1 genes were studied by molecular analyses

  14. Evaluation of Micro-organism in Ligated Metal and Self-ligating Brackets using Scanning Electron Microscopy: An In Vivo Study.

    Science.gov (United States)

    Sunil, P C; Michael, Tony; Raju, Aravind S; Paul, Renji K; Mamatha, J; Ebin, T M

    2015-07-01

    The objective of the study was to determine the sites of plaque accumulation and to compare the plaque accumulated with metal and self-ligating orthodontic brackets in order to know which bracket type had a higher plaque retaining capacity. The study was done on 20 subjects who were scheduled for orthodontic treatment including extraction of four premolars and fixed orthodontic appliances. Mesh-backed edgewise metal brackets ligated with steel ligatures and self-ligating brackets were bonded to the premolars to be extracted using composite (Transbond XT, 3M). The subjects were told to continue their normal oral hygiene regimen. Teeth were extracted at 1, 2, and 3 weeks after bracket bonding. Plaque attached to the buccal surfaces was stained using plaque disclosing agent. The teeth were then immersed in fixative containing 4% formaldehyde and 1% glutaraldehyde in phosphate buffer for 24 h, followed by 0.1 M phosphate buffer for 12 h. The specimens were then mounted on aluminum stubs, and sputter coated with gold prior to Scanning electron microscopy examination. The results showed that increased retention of plaque in metal brackets ligated with steel ligatures and comparatively less in self-ligating brackets at the base of the brackets. This study highlights that higher retention of plaque in metal brackets ligated with steel ligatures and comparatively less plaque retention in self-ligating brackets. Excess composite around the bracket base is the critical site of plaque accumulation associated with fixed appliances due to its rough surface texture.

  15. Hemorrhoidectomy: pedicle ligation vs pedicle coagulation

    International Nuclear Information System (INIS)

    Shaikh, B.S.; Balaoch, I.B.; Sohu, K.M.

    2015-01-01

    Objective: To compare the outcome of pedicle ligation vs pedicle coagulation haemorrhoidectomy. Methodology: This comparative prospective study was carried out at Department of Surgery, Ghulam Muhammad Maher Medcial College Hospital, Sukkur, Pakistan from January 2011 to January 2013 and included 300 patients of hemorrhoids. After routine workup, patients were randomly divided into two equal groups with one group receiving pedicle ligation and other pedicle coagulation for hemorrhoidectomy. Postoperatively they were followed for a period of 8 weeks for complications including pain, urinary retention, bleeding and anal stricture. Pain was recorded up to 10th postoperative day on the basis of visual analogue scale. Results: Mean age was 45 years and male to female ratio was 1.7:1. Mean operative time in pedicle ligation group was 15 min (range 14-20 min) and 17 min (15-25 min) in pedicle coagulation group. In Pedicle ligation group, pain was worst in 35 patients, moderate in 85 and mild in 30 patients; on the other hand in pedicle coagulation group, just 09 patients experienced worst pain. Urinary retention was observed in 44 patients in pedicle ligation group and 19 in pedicle coagulation group. Five patients in pedicle ligation group developed bleeding after their discharge from hospital; 7 patients in pedicle coagulation group reported secondary bleeding. Anal stricture was a rare complication and was found equally common in both the groups. Conclusion: Conventional hemorrhoidectomy with pedicle coagulation is an effective treatment modality for hemorrhoids and is associated with less chance of postoperative anal pain and urinary retention. (author)

  16. Esophageal variceal ligation in the secondary prevention of variceal ...

    African Journals Online (AJOL)

    Pan African Medical Journal ... Introduction: Long-term outcome of patients after band ligation have been poorly defined. ... endoscopic band ligation, liver cirrhosis, complication of band ligation, esophageal varices, secondary prevention ...

  17. Torque expression in self-ligating orthodontic brackets and conventionally ligated brackets: A systematic review

    OpenAIRE

    Al-Thomali, Yousef; Mohamed, Roshan-Noor; Basha, Sakeenabi

    2017-01-01

    Background To evaluate the torque expression of self ligating (SL) orthodontic brackets and conventionally ligated brackets and the torque expression in active and passive SL brackets. Material and Methods Our systematic search included MEDLINE, EMBASE, CINAHL, PsychINFO, Scopus, and key journals and review articles; the date of the last search was April 4th 2016. We graded the methodological quality of the studies by means of the Quality Assessment Tool for Quantitative Studies, developed fo...

  18. A cascade amplification strategy based on rolling circle amplification and hydroxylamine amplified gold nanoparticles enables chemiluminescence detection of adenosine triphosphate.

    Science.gov (United States)

    Wang, Ping; Zhang, Tonghuan; Yang, Taoyi; Jin, Nan; Zhao, Yanjun; Fan, Aiping

    2014-08-07

    A highly sensitive and selective chemiluminescent (CL) biosensor for adenosine triphosphate (ATP) was developed by taking advantage of the ATP-dependent enzymatic reaction (ATP-DER), the powerful signal amplification capability of rolling circle amplification (RCA), and hydroxylamine-amplified gold nanoparticles (Au NPs). The strategy relies on the ability of ATP, a cofactor of T4 DNA ligase, to trigger the ligation-RCA reaction. In the presence of ATP, the T4 DNA ligase catalyzes the ligation reaction between the two ends of the padlock probe, producing a closed circular DNA template that initiates the RCA reaction with phi29 DNA polymerase and dNTP. Therein, many complementary copies of the circular template can be generated. The ATP-DER is eventually converted into a detectable CL signal after a series of processes, including gold probe hybridization, hydroxylamine amplification, and oxidative gold metal dissolution coupled with a simple and sensitive luminol CL reaction. The CL signal is directly proportional to the ATP level. The results showed that the detection limit of the assay is 100 pM of ATP, which compares favorably with those of other ATP detection techniques. In addition, by taking advantage of ATP-DER, the proposed CL sensing system exhibits extraordinary specificity towards ATP and could distinguish the target molecule ATP from its analogues. The proposed method provides a new and versatile platform for the design of novel DNA ligation reaction-based CL sensing systems for other cofactors. This novel ATP-DER based CL sensing system may find wide applications in clinical diagnosis as well as in environmental and biomedical fields.

  19. Chemical Ligation Reactions of Oligonucleotides for Biological and Medicinal Applications.

    Science.gov (United States)

    Abe, Hiroshi; Kimura, Yasuaki

    2018-01-01

    Chemical ligation of oligonucleotides (ONs) is the key reaction for various ON-based technologies. We have tried to solve the problems of RNA interference (RNAi) technology by applying ON chemical ligation to RNAi. We designed a new RNAi system, called intracellular buildup RNAi (IBR-RNAi), where the RNA fragments are built up into active small-interference RNA (siRNA) in cells through a chemical ligation reaction. Using the phosphorothioate and iodoacetyl groups as reactive functional groups for the ligation, we achieved RNAi effects without inducing immune responses. Additionally, we developed a new chemical ligation for IBR-RNAi, which affords a more native-like structure in the ligated product. The new ligation method should be useful not only for IBR-RNAi but also for the chemical synthesis of biofunctional ONs.

  20. Venous surgery in erectile dysfunction. The role of dorsal-penile-vein ligation and spongiosolysis for impotence.

    Science.gov (United States)

    Gilbert, P; Sparwasser, C; Beckert, R; Treiber, U; Pust, R

    1992-01-01

    We report here on our surgical experience with venous leakage of the cavernous bodies. Out of 159 patients operated on, 134 were available for long-term follow-up. Depending on the cavernosographic findings, one of three different surgical procedures was carried out: ligation of the deep dorsal vein of the penis, spongiosolysis, or ligation of the crura. 18% of the patients undergoing ligation of the deep dorsal vein, postoperatively attained spontaneous erections, while 35% needed adjuvant corpus cavernosum autoinjection therapy. Spongiosolysis gave a more favourable result: spontaneous erections in 30% and vasoactive drug-dependent erections in 35%. Crural ligation did not prove successful. No serious complications were encountered postoperatively. Our data suggest that venous surgery should only be offered to a selected group of patients comprising young impotent men with venous leakage, maybe in combination with arterial disease, and patients suffering from distal venous leakage. Old age, neurogenic disorders causing erectile dysfunction, and diabetes mellitus should represent exclusion criteria for venous surgery.

  1. [Friction: self-ligating brackets].

    Science.gov (United States)

    Thermac, Guilhem; Morgon, Laurent; Godeneche, Julien

    2008-12-01

    The manufacturers of self-ligating brackets advertise a reduction of the friction engendered between the wire and the bracket, which is an essential parameter for treatment's speed and comfort. We have compared the friction obtained with four types of self-ligating brackets - In-Ovation R, Damon 3, Smart Clip and Quick - with that of a standard bracket Omniarch associated with an elastomeric ligature. All bracket were tested on a bench of traction with three types of wires: steel .019"x.025", TMA .019"x.025" and NEO sentalloy F300 .020"x.020". The results confirm a clear friction reduction for all tested wire.

  2. Arterial ligation versus embolization in epistaxis management: Counterintuitive national trends.

    Science.gov (United States)

    Sylvester, Michael J; Chung, Sei Y; Guinand, Luis A; Govindan, Aparna; Baredes, Soly; Eloy, Jean Anderson

    2017-05-01

    Arterial ligation and embolization are treatment modalities indicated in severe and refractory epistaxis. The purpose of this study was to examine temporal trends and compare outcomes in treatment of hospitalized epistaxis patients with ligation or embolization. This retrospective cohort analysis utilized the 2008 to 2013 National Inpatient Sample to identify patients admitted with a primary diagnosis of epistaxis, and an associated procedure code for ligation or embolization. A total of 1,813 cases met the inclusion criteria, with 57.1% undergoing ligation. During the study period, treatment with ligation has trended downward, whereas treatment with embolization has remained constant. Overall, ligated patients were older (64.1 vs. 62.4 years; P = 0.027) and had higher rates of congestive heart failure (15.1% vs. 9.8%; P = 0.001). No significant differences in rates of chronic pulmonary disease, coagulopathy, liver disease, or hereditary hemorrhagic telangiectasia were observed between cohorts. No differences were observed in rates of blood transfusion, stroke, blindness, or in-hospital mortality; however, ligated patients had lower rates of intubation/tracheostomy (2.8% vs. 5.3%; P = 0.009). Ligated patients also experienced shorter hospital stays (3.6 vs. 4.0 days; P = 0.014) and incurred lower hospital charges ($33,029 vs. $69,304; P < 0.001). Compared to embolization, ligation is associated with significantly decreased hospital charges and shorter hospital stay, without an increase in complication rates. Counterintuitively, ligation appears to be trending downward nationally in its use relative to embolization. 2C Laryngoscope, 127:1017-1020, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  3. Norepinephrine ignites local hotspots of neuronal excitation: How arousal amplifies selectivity in perception and memory.

    Science.gov (United States)

    Mather, Mara; Clewett, David; Sakaki, Michiko; Harley, Carolyn W

    2016-01-01

    Emotional arousal enhances perception and memory of high-priority information but impairs processing of other information. Here, we propose that, under arousal, local glutamate levels signal the current strength of a representation and interact with norepinephrine (NE) to enhance high priority representations and out-compete or suppress lower priority representations. In our "glutamate amplifies noradrenergic effects" (GANE) model, high glutamate at the site of prioritized representations increases local NE release from the locus coeruleus (LC) to generate "NE hotspots." At these NE hotspots, local glutamate and NE release are mutually enhancing and amplify activation of prioritized representations. In contrast, arousal-induced LC activity inhibits less active representations via two mechanisms: 1) Where there are hotspots, lateral inhibition is amplified; 2) Where no hotspots emerge, NE levels are only high enough to activate low-threshold inhibitory adrenoreceptors. Thus, LC activation promotes a few hotspots of excitation in the context of widespread suppression, enhancing high priority representations while suppressing the rest. Hotspots also help synchronize oscillations across neural ensembles transmitting high-priority information. Furthermore, brain structures that detect stimulus priority interact with phasic NE release to preferentially route such information through large-scale functional brain networks. A surge of NE before, during, or after encoding enhances synaptic plasticity at NE hotspots, triggering local protein synthesis processes that enhance selective memory consolidation. Together, these noradrenergic mechanisms promote selective attention and memory under arousal. GANE not only reconciles apparently contradictory findings in the emotion-cognition literature but also extends previous influential theories of LC neuromodulation by proposing specific mechanisms for how LC-NE activity increases neural gain.

  4. Enhanced performance CCD output amplifier

    Science.gov (United States)

    Dunham, Mark E.; Morley, David W.

    1996-01-01

    A low-noise FET amplifier is connected to amplify output charge from a che coupled device (CCD). The FET has its gate connected to the CCD in common source configuration for receiving the output charge signal from the CCD and output an intermediate signal at a drain of the FET. An intermediate amplifier is connected to the drain of the FET for receiving the intermediate signal and outputting a low-noise signal functionally related to the output charge signal from the CCD. The amplifier is preferably connected as a virtual ground to the FET drain. The inherent shunt capacitance of the FET is selected to be at least equal to the sum of the remaining capacitances.

  5. Comparison of Hi-C results using in-solution versus in-nucleus ligation.

    Science.gov (United States)

    Nagano, Takashi; Várnai, Csilla; Schoenfelder, Stefan; Javierre, Biola-Maria; Wingett, Steven W; Fraser, Peter

    2015-08-26

    Chromosome conformation capture and various derivative methods such as 4C, 5C and Hi-C have emerged as standard tools to analyze the three-dimensional organization of the genome in the nucleus. These methods employ ligation of diluted cross-linked chromatin complexes, intended to favor proximity-dependent, intra-complex ligation. During development of single-cell Hi-C, we devised an alternative Hi-C protocol with ligation in preserved nuclei rather than in solution. Here we directly compare Hi-C methods employing in-nucleus ligation with the standard in-solution ligation. We show in-nucleus ligation results in consistently lower levels of inter-chromosomal contacts. Through chromatin mixing experiments we show that a significantly large fraction of inter-chromosomal contacts are the result of spurious ligation events formed during in-solution ligation. In-nucleus ligation significantly reduces this source of experimental noise, and results in improved reproducibility between replicates. We also find that in-nucleus ligation eliminates restriction fragment length bias found with in-solution ligation. These improvements result in greater reproducibility of long-range intra-chromosomal and inter-chromosomal contacts, as well as enhanced detection of structural features such as topologically associated domain boundaries. We conclude that in-nucleus ligation captures chromatin interactions more consistently over a wider range of distances, and significantly reduces both experimental noise and bias. In-nucleus ligation creates higher quality Hi-C libraries while simplifying the experimental procedure. We suggest that the entire range of 3C applications are likely to show similar benefits from in-nucleus ligation.

  6. Robot-assisted ligation of bronchial artery could be an alternative to embolization.

    Science.gov (United States)

    Pochulu, Bruno; Sarsam, Omar; Peillon, Christophe; Baste, Jean-Marc

    2018-03-01

    A 37-year-old patient presented with a self-limiting episode of moderate haemoptysis. Contrast-enhanced chest computed tomography showed a tortuous and dilated right bronchial artery arising from the descending aorta at the level of T6. Therapeutic angiography was attempted, but in the presence of spinal artery arising from the bronchial artery in question, selective embolization was contraindicated due to risk of spinal cord ischaemia. After a multidisciplinary meeting, it was decided to attempt surgery to ligate this pathological artery. We performed minimally invasive robot-assisted ligation of this pathological artery. The postoperative course was uneventful with good clinical and radiological outcome at 3-month follow-up. A minimally invasive approach provides a real alternative to embolization and could be a therapeutic option.

  7. Are self-ligating brackets related to less formation of Streptococcus mutans colonies? A systematic review

    Directory of Open Access Journals (Sweden)

    Leonard Euler Andrade Gomes do Nascimento

    2014-01-01

    Full Text Available OBJECTIVE: To verify, by means of a systematic review, whether the design of brackets (conventional or self-ligating influences adhesion and formation of Streptococcus mutans colonies. METHODS: Search strategy: four databases (Cochrane Central Register of Controlled Trials, Ovid ALL EMB Reviews, PubMed and BIREME were selected to search relevant articles covering the period from January 1965 to December 2012. Selection Criteria: in first consensus by reading the title and abstract. The full text was obtained from publications that met the inclusion criteria. Data collection and analysis: Two reviewers independently extracted data using the keywords: conventional, self-ligating, biofilm, Streptococcus mutans, and systematic review; and independently evaluated the quality of the studies. In case of divergence, the technique of consensus was adopted. RESULTS: The search strategy resulted in 1,401 articles. The classification of scientific relevance revealed the high quality of the 6 eligible articles of which outcomes were not unanimous in reporting not only the influence of the design of the brackets (conventional or self-ligating over adhesion and formation of colonies of Streptococcus mutans, but also that other factors such as the quality of the bracket type, the level of individual oral hygiene, bonding and age may have greater influence. Statistical analysis was not feasible because of the heterogeneous methodological design. CONCLUSIONS: Within the limitations of this study, it was concluded that there is no evidence for a possible influence of the design of the brackets (conventional or self-ligating over colony formation and adhesion of Streptococcus mutans.

  8. Recovery of testicular blood flow following ligation of testicular vessels

    International Nuclear Information System (INIS)

    Pascual, J.A.; Villanueva-Meyer, J.; Salido, E.; Ehrlich, R.M.; Mena, I.; Rajfer, J.

    1989-01-01

    To determine whether initial ligation of the testicular vessels of the high undescended testis followed by a delayed secondary orchiopexy is a viable alternative to the classical Fowler-Stephens procedure, a series of preliminary experiments were conducted in the rat in which testicular blood flow was measured by the 133-xenon washout technique before, and 1 hour and 30 days after ligation of the vessels. In addition, testicular histology, and testis and sex-accessory tissue weights were measured in 6 control, 6 sham operated and 6 testicular vessel ligated rats 54 days after vessel ligation. The data demonstrate that ligation and division of the testicular blood vessels produce an 80 per cent decrease in testicular blood flow 1 hour after ligation of the vessels. However, 30 days later testis blood flow returns to the control and pre-treatment value. There were no significant changes in testis or sex-accessory tissue weights 54 days after vessel ligation. Histologically, 4 of the surgically operated testes demonstrated necrosis of less than 25 per cent of the seminiferous tubules while 1 testis demonstrated more than 75 per cent necrosis. The rest of the tubules in all 6 testes demonstrated normal spermatogenesis. From this study we conclude that initial testicular vessel ligation produces an immediate decrease in testicular blood flow but with time the collateral vessels are able to compensate and return the testis blood flow to its normal pre-treatment value. These preliminary observations lend support for the concept that initial ligation of the testicular vessels followed by a delayed secondary orchiopexy in patients with a high undescended testis may be a possible alternative to the classical Fowler-Stephens approach

  9. [Rubber band ligation in treatment of hemorrhoids: our experience].

    Science.gov (United States)

    Gaj, F; Biviano, I; Sportelli, G; Candeloro, L

    2015-01-01

    Hemorrhoids are a very common condition. The treatment depends upon persistence and severity of symptoms. For hemorrhoids of II and III grade the rubber band ligation may be therapeutic. Our aim is to report the outcomes of rubber band ligation of hemorrhoids, with a follow up of 6 months. A total of 50 patients underwent rubber band ligation for symptomatic hemorrhoids (grade II and III) without prolapse, between June 2012 and June 2014. All patients underwent plug test to rule out presence of rectal mucosal prolapse and were classified according to PATE classification (1). Each hemorrhoid was ligated with one rubber band through a ligator. All patients were evaluated immediately at the end of the procedure, after ten days and six months after the treatment. Patient's demographic and operative data were collected and analyzed. The mean patients age was 47.6±12.3 years (range 24-72). All procedures were performed without complications. Before rubber band ligation, 42 patients had rectal bleeding, 38 had perineal discomfort and 27 had itching. Ten days after the treatment, 12 patients presented self-limited rectal bleeding, but 10 of these had more hemorrhoids and underwent a second rubber band ligation. No patients complained perineal discomfort, and 8 patients had itching; 78% and 16% of patients respectively, experienced feeling of a foreign body inside the canal anal and anal pain. After 6 months, only 13 patients were occasionally symptomatic: 4 patients had rectal bleeding, 2 had perineal discomfort and 4 had itching. Three more patients presented both perineal discomfort and hitching. None had the feeling of a foreign body in anal canal or anal pain. Rubber band ligation is an efficacious, cost-effective and simple treatment for the second and third degree hemorrhoids without rectal mucosal prolapsed. In our hands, no severe complications developed and minor complications could be handled with ease.

  10. Tubal ligation and risk of ovarian cancer subtypes

    DEFF Research Database (Denmark)

    Sieh, Weiva; Salvador, Shannon; McGuire, Valerie

    2013-01-01

    Tubal ligation is a protective factor for ovarian cancer, but it is unknown whether this protection extends to all invasive histological subtypes or borderline tumors. We undertook an international collaborative study to examine the association between tubal ligation and ovarian cancer subtypes....

  11. A hybrid polarization-selective atomic sensor for radio-frequency field detection with a passive resonant-cavity field amplifier

    OpenAIRE

    Anderson, David A.; Paradis, Eric G.; Raithel, Georg

    2018-01-01

    We present a hybrid atomic sensor that realizes radio-frequency electric field detection with intrinsic field amplification and polarization selectivity for robust high-sensitivity field measurement. The hybrid sensor incorporates a passive resonator element integrated with an atomic vapor cell that provides amplification and polarization selectivity for detection of incident radio-frequency fields. The amplified intra-cavity radio-frequency field is measured by atoms using a quantum-optical ...

  12. Molecular markers. Amplified fragment length polymorphism

    Directory of Open Access Journals (Sweden)

    Pržulj Novo

    2005-01-01

    Full Text Available Amplified Fragment Length Polymorphism molecular markers (AFLPs has been developed combining procedures of RFLPs and RAPDs molekular markers, i.e. the first step is restriction digestion of the genomic DNA that is followed by selective amplification of the restricted fragments. The advantage of the AFLP technique is that it allows rapid generation of a large number of reproducible markers. The reproducibility of AFLPs markers is assured by the use of restriction site-specific adapters and adapter-specific primers for PCR reaction. Only fragments containing the restriction site sequence plus the additional nucleotides will be amplified and the more selected nucleotides added on the primer sequence the fewer the number of fragments amplified by PCR. The amplified products are normally separated on a sequencing gel and visualized after exposure to X-ray film or by using fluorescent labeled primers. AFLP shave proven to be extremely proficient in revealing diversity at below the species level. A disadvantage of AFLP technique is that AFLPs are essentially a dominant marker system and not able to identify heterozygotes.

  13. Psychosocial implications of tubal ligation in a rural health district: A phenomenological study

    Directory of Open Access Journals (Sweden)

    Lutala Prosper M

    2011-12-01

    Full Text Available Abstract Background Tubal ligation is the most popular family planning method worldwide. While its benefits, such as effectiveness in protecting against pregnancies, minimal need for long-term follow-up and low side-effects profile are well documented, it has many reported complications. However, to date, these complications have not been described by residents in Congo. Therefore, the study aimed at exploring the experience of women who had undergone tubal ligation, focusing on perceptions of physical, psychological and contextual experiences of participants. Methods This qualitative study used a semi-structured questionnaire in a phenomenological paradigm to collect data. Fifteen participants were purposefully selected among sterilized women who had a ligation procedure performed, were aged between 30 and 40 years, and were living within the catchment area of the district hospital. Data were collected by two registered nurses, tape-recorded, and transcribed verbatim. Reading and re-reading cut and paste techniques, and integration were used to establish codes, categories, themes, and description. Results Diverse and sometimes opposite changes in somatic symptoms, psychological symptoms, productivity, ecological relationships, doctor-client relationships, ethical issues, and change of life style were the major problem domains. Conclusions Clients reported conflicting experiences in several areas of their lives after tubal sterilization. Management, including awareness of the particular features of the client, is needed to decrease the likelihood of psychosocial morbidity and/or to select clients in need of sterilization.

  14. Convergent synthesis of proteins by kinetically controlled ligation

    Science.gov (United States)

    Kent, Stephen; Pentelute, Brad; Bang, Duhee; Johnson, Erik; Durek, Thomas

    2010-03-09

    The present invention concerns methods and compositions for synthesizing a polypeptide using kinetically controlled reactions involving fragments of the polypeptide for a fully convergent process. In more specific embodiments, a ligation involves reacting a first peptide having a protected cysteyl group at its N-terminal and a phenylthioester at its C-terminal with a second peptide having a cysteine residue at its N-termini and a thioester at its C-termini to form a ligation product. Subsequent reactions may involve deprotecting the cysteyl group of the resulting ligation product and/or converting the thioester into a thiophenylester.

  15. Isolation and characterization of microsatellite DNA loci from Sillago ...

    Indian Academy of Sciences (India)

    A diluted digestion–ligation mixture (1:10) was amplified with adaptor-specific primers (MSEP: 5 -GAT GAG TCC. TGA GTA A-3 ). Amplified DNA fragments, with a size range of 200–1000 bp, were enriched for repeats by mag- netic bead selection with a 5 -biotinylated (AC)15 probes, respectively. Enriched fragments were ...

  16. Laparoscopic-assisted percutaneous internal ring ligation in children

    African Journals Online (AJOL)

    Annals of Pediatric Surgery ... Patients and methods Laparoscopic percutaneous ligation of internal inguinal ring has been ... The mean operative time in our series was 15 (± 3) and 20 (± 5) min for bilateral cases, without anesthesia time. ... Conclusion Laparoscopic percutaneous ligation of internal inguinal ring repair of ...

  17. Conversion of the random amplified polymorphic DNA (RAPD ...

    African Journals Online (AJOL)

    Conversion of the random amplified polymorphic DNA (RAPD) marker UBC#116 linked to Fusarium crown and root rot resistance gene (Frl) into a co-dominant sequence characterized amplified region (SCAR) marker for marker-assisted selection of tomato.

  18. Persistent postpartum haemorrhage after failed arterial ligation: value of pelvic embolisation

    Energy Technology Data Exchange (ETDEWEB)

    Fargeaudou, Yann; Soyer, Philippe; Sirol, Marc; Boudiaf, Mourad; Dahan, Henri; Dref, Olivier le [Hopital Lariboisiere AP-HP et Universite Diderot-Paris 7, Department of Abdominal and Interventional Imaging, Paris (France); Morel, Olivier; Barranger, Emmanuel [Hopital Lariboisiere AP-HP, Department of Obstetrics and Gynecology, Paris (France); Gayat, Etienne; Mebazaa, Alexandre [Hopital Lariboisiere AP-HP, Department of Anesthesiology and Intensive Care Medicine, Paris (France)

    2010-07-15

    To evaluate the role and efficacy of pelvic embolisation in the treatment of persistent postpartum haemorrhage after failed arterial ligation and to identify the complications of this procedure in this specific population. The clinical files and angiographic examinations of 12 consecutive women (mean age 32 years) who were treated with pelvic embolisation because of persistent, severe postpartum haemorrhage after failed arterial ligation were reviewed. Angiography revealed that persistent bleeding was due to incomplete arterial ligation (n = 4) or the presence of newly developed anastomotic routes (n = 8). In 11 women, pelvic embolisation stopped the bleeding. Hysterectomy was needed in one woman with retained placenta. Two complications due to pelvic embolisation, including leg ischaemia and transient sciatic nerve ischaemia, were identified, both after internal iliac artery ligation. In women with persistent postpartum haemorrhage after failed arterial ligation, pelvic embolisation is an effective treatment in most cases. However, embolisation of the anastomotic routes that contribute to persistent bleeding may result in ischaemic complications. These potential complications reaffirm that arterial ligation should not be the favoured option for postpartum haemorrhage and that special care must be given during pelvic embolisation after failed arterial ligation. (orig.)

  19. Hypotension following patent ductus arteriosus ligation: The role of adrenal hormones

    OpenAIRE

    Clyman, RI; Wickremasinghe, A; Merritt, TA; Solomon, T; McNamara, P; Jain, A; Singh, J; Chu, A; Noori, S; Sekar, K; Lavoie, PM; Attridge, JT; Swanson, JR; Gillam-Krakauer, M; Reese, J

    2014-01-01

    Objective To test the hypothesis that an impaired adrenal response to stress might play a role in the hypotension that follows patent ductus arteriosus (PDA) ligation. Study design We performed a multicenter study of infants born at < 32 weeks' gestation who were about to undergo PDA ligation. Serum adrenal steroids were measured 3 times: before and after a cosyntropin (1.0 μg/kg) stimulation test (performed before the ligation), and at 10-12 hours after the ligation. A standardized approach...

  20. E-cadherin homophilic ligation inhibits cell growth and epidermal growth factor receptor signaling independently of other cell interactions

    DEFF Research Database (Denmark)

    Perrais, Michaël; Chen, Xiao; Perez-Moreno, Mirna

    2007-01-01

    growth inhibitory signals. To address this question, we have selectively formed E-cadherin homophilic bonds at the cell surface of isolated epithelial cells by using functionally active recombinant E-cadherin protein attached to microspheres. We find that E-cadherin ligation alone reduces the frequency...... of cells entering the S phase, demonstrating that E-cadherin ligation directly transduces growth inhibitory signals. E-cadherin binding to beta-catenin is required for cell growth inhibition, but beta-catenin/T-cell factor transcriptional activity is not involved in growth inhibition resulting from...... homophilic binding. Neither E-cadherin binding to p120-catenin nor beta-catenin binding to alpha-catenin, and thereby the actin cytoskeleton, is required for growth inhibition. E-cadherin ligation also inhibits epidermal growth factor (EGF) receptor-mediated growth signaling by a beta...

  1. Mandibular Dental Arch Changes with Active Self‑ligating Brackets ...

    African Journals Online (AJOL)

    ... with different forms of archwires with a control group in nonextraction cases. ... into three groups: Group I was treated with active self‑ligating brackets (Nexus, ... (SS) wires; Group II was treated with interactive self‑ligating bracket system ...

  2. Alterations in plaque accumulation and gingival inflammation promoted by treatment with self-ligating and conventional orthodontic brackets.

    Science.gov (United States)

    Cardoso, Mauricio de Almeida; Saraiva, Patrícia Pinto; Maltagliati, Liliana Ávila; Rhoden, Fernando Kleinübing; Costa, Carla Cristina Alvarenga; Normando, David; Capelozza Filho, Leopoldino

    2015-01-01

    The aim of the present study was to evaluate, comparatively, the periodontal response during orthodontic treatment performed with self-ligating and conventional brackets. Sixteen Caucasian individuals of both sexes, aged between 12 and 16 years old and in permanent dentition were selected. Eight individuals were treated with conventional brackets installed on the lower dental arch and self-ligating brackets on the upper arch. Another eight individuals received self-ligating brackets in the lower arch and conventional brackets in the upper arch. The subjects received material and instructions for oral hygiene. Visible plaque index (VPI), gingival bleeding index (GBI) and clinical attachment level (CAL) were evaluated just after installation of orthodontic appliances, and 30, 60 and 180 days later. Mann-Whitney test was used to compare differences between groups (self-ligating and conventional), two-way ANOVA followed by Tukey's test was used to assess CAL at each site of each tooth. Significance level was set at 5%. No significant changes were found with regard to the assessed parameters (VPI, GBI and CAL) in either one of the systems. No significant changes were found with regard to the periodontal response to orthodontic treatment for the variables assessed and between subjects receiving passive self-ligating and conventional brackets. All individuals had received oral hygiene instructions and had their periodontal conditions monitored.

  3. Alterations in plaque accumulation and gingival inflammation promoted by treatment with self-ligating and conventional orthodontic brackets

    Directory of Open Access Journals (Sweden)

    Mauricio de Almeida Cardoso

    2015-04-01

    Full Text Available OBJECTIVE: The aim of the present study was to evaluate, comparatively, the periodontal response during orthodontic treatment performed with self-ligating and conventional brackets. METHODS: Sixteen Caucasian individuals of both sexes, aged between 12 and 16 years old and in permanent dentition were selected. Eight individuals were treated with conventional brackets installed on the lower dental arch and self-ligating brackets on the upper arch. Another eight individuals received self-ligating brackets in the lower arch and conventional brackets in the upper arch. The subjects received material and instructions for oral hygiene. Visible plaque index (VPI, gingival bleeding index (GBI and clinical attachment level (CAL were evaluated just after installation of orthodontic appliances, and 30, 60 and 180 days later. Mann-Whitney test was used to compare differences between groups (self-ligating and conventional, two-way ANOVA followed by Tukey's test was used to assess CAL at each site of each tooth. Significance level was set at 5%. RESULTS: No significant changes were found with regard to the assessed parameters (VPI, GBI and CAL in either one of the systems. CONCLUSION: No significant changes were found with regard to the periodontal response to orthodontic treatment for the variables assessed and between subjects receiving passive self-ligating and conventional brackets. All individuals had received oral hygiene instructions and had their periodontal conditions monitored.

  4. Template-Directed Ligation of Peptides to Oligonucleotides

    Science.gov (United States)

    Bruick, Richard K.; Dawson, Philip E.; Kent, Stephen BH; Usman, Nassim; Joyce, Gerald F.

    1996-01-01

    Synthetic oligonucleotides and peptides have enjoyed a wide range of applications in both biology and chemistry. As a consequence, oligonucleotide-peptide conjugates have received considerable attention, most notably in the development of antisense constructs with improved pharmacological properties. In addition, oligonucleotide-peptide conjugates have been used as molecular tags, in the assembly of supramolecular arrays and in the construction of encoded combinatorial libraries. To make these chimeric molecules more accessible for a broad range of investigations, we sought to develop a facile method for joining fully deprotected oligonucleotides and peptides through a stable amide bond linkage. Furthermore, we wished to make this ligation reaction addressable, enabling one to direct the ligation of specific oligonucleotide and peptide components.To confer specificity and accelerate the rate of the reaction, the ligation process was designed to be dependent on the presence of a complementary oligonucleotide template.

  5. Coordination-Assisted Bioorthogonal Chemistry: Orthogonal Tetrazine Ligation with Vinylboronic Acid and a Strained Alkene.

    Science.gov (United States)

    Eising, Selma; Xin, Bo-Tao; Kleinpenning, Fleur; Heming, Juriaan; Florea, Bogdan; Overkleeft, Herman; Bonger, Kimberly Michelle

    2018-05-28

    Bioorthogonal chemistry can be used for the selective modification of biomolecules without interfering with any other functionality present. Recent developments in the field provided orthogonal bioorthogonal reactions for modification of multiple biomolecules simultaneously. During our research, we have observed exceptional high reaction rates in the bioorthogonal inverse electron-demand Diels-Alder (iEDDA) reaction between non-strained vinylboronic acids (VBAs) and dipyridyl-s-tetrazines relative to that of tetrazines bearing a methyl or phenyl substituent. As VBAs are mild Lewis acids, we hypothesize that coordination of the pyridyl nitrogen to the boronic acid promotes the tetrazine ligation. Here, we explore the molecular basis and scope of the VBA-tetrazine ligation in more detail and benefit from its unique reactivity in the simultaneous orthogonal tetrazine labelling of two proteins modified with VBA and norbornene, a widely used strained alkene. We further show that the two orthogonal iEDDA reactions can be carried out in living cells by labelling of the proteasome using a non-selective probe equipped with a VBA and a subunit-selective one bearing a norbornene. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Time course of collagen peak in bile duct-ligated rats.

    Science.gov (United States)

    Tarcin, Orhan; Basaranoglu, Metin; Tahan, Veysel; Tahan, Gülgün; Sücüllü, Ilker; Yilmaz, Nevin; Sood, Gagan; Snyder, Ned; Hilman, Gilbert; Celikel, Cigdem; Tözün, Nurdan

    2011-04-28

    One of the most useful experimental fibrogenesis models is the "bile duct-ligated rats". Our aim was to investigate the quantitative hepatic collagen content by two different methods during the different stages of hepatic fibrosis in bile duct-ligated rats on a weekly basis. We questioned whether the 1-wk or 4-wk bile duct-ligated model is suitable in animal fibrogenesis trials. Of the 53 male Wistar rats, 8 (Group 0) were used as a healthy control group. Bile duct ligation (BDL) had been performed in the rest. Bile duct-ligated rates were sacrificed 7 days later in group 1 (10 rats), 14 days later in group 2 (9 rats), 21 days later in group 3(9 rats) and 28 days later in group 4 (9 rats). Eight rats underwent sham-operation (Sham). Hepatic collagen measurements as well as serum levels of liver enzymes and function tests were all analysed. The peak level of collagen was observed biochemically and histomorphometricly at the end of third week (P fibrosis in bile duct-ligated rats is transient, i.e. reverses spontaneously after 3 weeks. This contrasts any situation in patients where hepatic fibrosis is progressive and irreversible as countless studies performed by many investigators in the same animal model.

  7. Effects of self-ligating and conventional brackets on halitosis and periodontal conditions.

    Science.gov (United States)

    Kaygisiz, Emine; Uzuner, Fatma Deniz; Yuksel, Sema; Taner, Levent; Çulhaoğlu, Rana; Sezgin, Yasemin; Ateş, Can

    2015-05-01

    To evaluate the effects of fixed orthodontic treatment with steel-ligated conventional brackets and self-ligating brackets on halitosis and periodontal health. Sixty patients, at the permanent dentition stage aged 12 to 18 years, who had Angle Class I malocclusion with mild-to-moderate crowding were randomly selected. Inclusion criteria were nonsmokers, without systematic disease, and no use of antibiotics and oral mouth rinses during the 2-month period before the study. The patients were subdivided into three groups randomly: the group treated with conventional brackets (group 1, n  =  20) ligated with steel ligature wires, the group treated with self-ligating brackets (group 2, n  =  20), and the control group (group 3, n  =  20). The periodontal records were obtained 1 week before bonding (T1), immediately before bonding (T2), 1 week after bonding (T3), 4 weeks after bonding (T4), and 8 weeks after bonding (T5). Measurements of the control group were repeated within the same periods. The volatile sulfur components determining halitosis were measured with the Halimeter at T2, T3, T4, and T5. A two-way repeated measures of analysis of variance (ANOVA) was used to compare the groups statistically. No statistically significant group × time interactions were found for plaque index, gingival index, pocket depth, bleeding on probing, and halitosis, which means three independent groups change like each other by time. The risk of tongue coating index (TCI) being 2 was 10.2 times higher at T1 than at T5 (P brackets do not have an advantage over conventional brackets with respect to periodontal status and halitosis.

  8. Methylphenidate alters selective attention by amplifying salience.

    Science.gov (United States)

    ter Huurne, Niels; Fallon, Sean James; van Schouwenburg, Martine; van der Schaaf, Marieke; Buitelaar, Jan; Jensen, Ole; Cools, Roshan

    2015-12-01

    Methylphenidate, the most common treatment of attention deficit hyperactivity disorder (ADHD), is increasingly used by healthy individuals as a "smart drug" to enhance cognitive abilities like attention. A key feature of (selective) attention is the ability to ignore irrelevant but salient information in the environment (distractors). Although crucial for cognitive performance, until now, it is not known how the use of methylphenidate affects resistance to attentional capture by distractors. The present study aims to clarify how methylphenidate affects distractor suppression in healthy individuals. The effect of methylphenidate (20 mg) on distractor suppression was assessed in healthy subjects (N = 20), in a within-subject double-blind placebo-controlled crossover design. We used a visuospatial attention task with target faces flanked by strong (faces) or weak distractors (scrambled faces). Methylphenidate increased accuracy on trials that required gender identification of target face stimuli (methylphenidate 88.9 ± 1.4 [mean ± SEM], placebo 86.0 ± 1.2 %; p = .003), suggesting increased processing of the faces. At the same time, however, methylphenidate increased reaction time when the target face was flanked by a face distractor relative to a scrambled face distractor (methylphenidate 34.9 ± 3.73, placebo 26.7 ± 2.84 ms; p = .027), suggesting enhanced attentional capture by distractors with task-relevant features. We conclude that methylphenidate amplifies salience of task-relevant information at the level of the stimulus category. This leads to enhanced processing of the target (faces) but also increased attentional capture by distractors drawn from the same category as the target.

  9. Ligation versus no ligation of spontaneous portosystemic shunts during liver transplantation: Audit of a prospective series of 66 consecutive patients.

    Science.gov (United States)

    Gomez Gavara, Concepcion; Bhangui, Prashant; Salloum, Chady; Osseis, Michael; Esposito, Francesco; Moussallem, Toufic; Lahat, Eylon; Fuentes, Liliana; Compagnon, Philippe; Ngongang, Norbert; Lim, Chetana; Azoulay, Daniel

    2018-04-01

    The management of large spontaneous portosystemic shunt (SPSS) during liver transplantation (LT) is a matter of debate. The aim of this study is to compare the short-term and longterm outcomes of SPSS ligation versus nonligation during LT, when both options are available. From 2011 to 2017, 66 patients with SPSS underwent LT: 56 without and 10 with portal vein thrombosis (PVT), all of whom underwent successful thrombectomy and could have portoportal reconstruction. The SPSS were either splenorenal (n = 40; 60.6%), left gastric (n = 16; 24.2%), or mesenterico-iliac (n = 10; 15.1%). Following portoportal anastomosis, the SPSS was ligated in 36 (54.4%) patients and left in place in 30 (45.5%) patients, based on the effect of the SPSS clamping/unclamping test on portal vein flow during the anhepatic phase. Intraoperatively, satisfactory portal flow was obtained in both groups. Primary nonfunction (PNF) and primary dysfunction (PDF) rates did not differ significantly between the 2 groups. Nonligation of SPSS was significantly associated with a higher rate of postoperative encephalopathy (P SPSS in LT (ie, PNF and PDF, PVT, and encephalopathy) was present in 16 (44.4%) and 22 (73.3%) patients of the ligated and nonligated shunt group, respectively (P = 0.02). Patient (P = 0.05) and graft (P = 0.02) survival rates were better in the ligated shunt group. In conclusion, the present study supports routine ligation of large SPSS during LT whenever feasible. Liver Transplantation 24 505-515 2018 AASLD. © 2018 by the American Association for the Study of Liver Diseases.

  10. Portal vein ligation is as effective as sequential portal vein and hepatic artery ligation in inducing contralateral liver hypertrophy in a rat model

    NARCIS (Netherlands)

    Veteläinen, Reeta; Dinant, Sander; van Vliet, Arlène; van Gulik, Thomas M.

    2006-01-01

    PURPOSE: Dual embolization of the hepatic artery and portal vein (PV) has been proposed to enhance contralateral liver regeneration before resection. The aim of this study was to evaluate the effect of PV ligation compared with simultaneous or sequential dual ligation on regeneration,

  11. Comparison of frictional resistance of esthetic and semi-esthetic self-ligating brackets

    Directory of Open Access Journals (Sweden)

    M S Kannan

    2015-01-01

    Full Text Available Aim: The frictional resistance encountered during sliding mechanics has been well established in the orthodontic literature, and it consists of complex interactions between the bracket, archwire, and method of ligation the claim of reduced friction with self-ligating brackets is often cited as a primary advantage over conventional brackets. This study was done to compare and evaluate the frictional forces generated between fully esthetic brackets and semi-aesthetic self-ligating brackets, which are of passive form and SEM (scanning electron microscope study of the Brackets after Frictional evaluation. Materials and Methods: Two types of self-ligating esthetic brackets, Damon clear (Ormco made of fully ceramic and Opal (Ultradent Products, USA and, Two types of self-ligating semi-esthetic brackets, Clarity SL (3M Unitek and Damon 3 (Ormco both of which are made of ceramic with metal slot. Arch wires with different dimensions and quality 17 × 25, 19 × 25 Titanium Molybdenum Alloy (TMA and 17 × 25, 19 × 25 stainless steel that came from plain strands of wire were used for frictional comparison test. The brackets used in this study had 0.022 × 0.028 inch slot. Results: The statistical tests showed significantly smaller amount of kinetic frictional forces is generated by Damon 3 (semi-esthetic self-ligating brackets. For each wire used, Damon 3 displayed significantly lower frictional forces (P ≤ 0.05 than any of the self-ligating system, followed by Opal (fully esthetic self-ligating brackets which generated smaller amount of frictional forces but relatively on the higher side when compared with Damon 3. Damon clear (fully esthetic self-ligating brackets generated the maximum amount of kinetic forces with all types of wire dimensions and properties when compared to the other three types of self-ligating system. Clarity SL (semi-esthetic self-ligating brackets generated smaller amount of frictional forces when compared with Damon clear and

  12. Comparison of frictional resistance of esthetic and semi-esthetic self-ligating brackets.

    Science.gov (United States)

    Kannan, M S; Murali, R V; Kishorekumar, S; Gnanashanmugam, K; Jayanth, V

    2015-04-01

    The frictional resistance encountered during sliding mechanics has been well established in the orthodontic literature, and it consists of complex interactions between the bracket, archwire, and method of ligation the claim of reduced friction with self-ligating brackets is often cited as a primary advantage over conventional brackets. This study was done to compare and evaluate the frictional forces generated between fully esthetic brackets and semi-aesthetic self-ligating brackets, which are of passive form and SEM (scanning electron microscope) study of the Brackets after Frictional evaluation. Two types of self-ligating esthetic brackets, Damon clear (Ormco) made of fully ceramic and Opal (Ultradent Products, USA) and, Two types of self-ligating semi-esthetic brackets, Clarity SL (3M Unitek) and Damon 3 (Ormco) both of which are made of ceramic with metal slot. Arch wires with different dimensions and quality 17 × 25, 19 × 25 Titanium Molybdenum Alloy (TMA) and 17 × 25, 19 × 25 stainless steel that came from plain strands of wire were used for frictional comparison test. The brackets used in this study had 0.022 × 0.028 inch slot. The statistical tests showed significantly smaller amount of kinetic frictional forces is generated by Damon 3 (semi-esthetic self-ligating brackets). For each wire used, Damon 3 displayed significantly lower frictional forces (P ≤ 0.05) than any of the self-ligating system, followed by Opal (fully esthetic self-ligating brackets) which generated smaller amount of frictional forces but relatively on the higher side when compared with Damon 3. Damon clear (fully esthetic self-ligating brackets) generated the maximum amount of kinetic forces with all types of wire dimensions and properties when compared to the other three types of self-ligating system. Clarity SL (semi-esthetic self-ligating brackets) generated smaller amount of frictional forces when compared with Damon clear and relatively higher amount of frictional forces

  13. Hemodynamic characterization of chronic bile duct-ligated rats: effect of pentobarbital sodium

    International Nuclear Information System (INIS)

    Lee, S.S.; Girod, C.; Braillon, A.; Hadengue, A.; Lebrec, D.

    1986-01-01

    Systemic and splanchnic hemodynamics of the chronic bile duct-ligated rat were characterized by radioactive microspheres. Conscious and pentobarbital sodium-anesthetized, bile duct-ligated and sham-operated rats had cardiac output and regional organ blood flows determined. The conscious bile duct-ligated rat compared with the sham-operated showed a hyperdynamic circulation with an increased cardiac output and portal tributary blood flow. Pentobarbital sodium anesthesia induced marked hemodynamic changes in both sham-operated and bile duct-ligated rats. The latter group was especially sensitive to its effects; thus, comparison of cardiac output and portal tributary blood flow between anesthetized bile duct-ligated and sham-operated rats showed no significant differences. The authors conclude that the rat with cirrhosis due to chronic bile duct ligation is an excellent model for hemodynamic investigations but should be studied in the conscious state, since pentobarbital sodium anesthesia eliminated the hyperdynamic circulation

  14. Esophageal variceal ligation for hemostasis of acute variceal bleeding

    African Journals Online (AJOL)

    Introduction: Endoscopic variceal ligation is widely accepted as the optimum endoscopic treatment for esophageal variceal hemorrhage. In Morocco, there are no data regarding the efficacy of this technique. Our aim was to evaluate the effectiveness and safety of endoscopic variceal ligation in the management of ...

  15. Time course of collagen peak in bile duct-ligated rats

    Directory of Open Access Journals (Sweden)

    Snyder Ned

    2011-04-01

    Full Text Available Abstract Background One of the most useful experimental fibrogenesis models is the "bile duct-ligated rats". Our aim was to investigate the quantitative hepatic collagen content by two different methods during the different stages of hepatic fibrosis in bile duct-ligated rats on a weekly basis. We questioned whether the 1-wk or 4-wk bile duct-ligated model is suitable in animal fibrogenesis trials. Methods Of the 53 male Wistar rats, 8 (Group 0 were used as a healthy control group. Bile duct ligation (BDL had been performed in the rest. Bile duct-ligated rates were sacrificed 7 days later in group 1 (10 rats, 14 days later in group 2 (9 rats, 21 days later in group 3(9 rats and 28 days later in group 4 (9 rats. Eight rats underwent sham-operation (Sham. Hepatic collagen measurements as well as serum levels of liver enzymes and function tests were all analysed. Results The peak level of collagen was observed biochemically and histomorphometricly at the end of third week (P Conclusion We have shown that fibrosis in bile duct-ligated rats is transient, i.e. reverses spontaneously after 3 weeks. This contrasts any situation in patients where hepatic fibrosis is progressive and irreversible as countless studies performed by many investigators in the same animal model.

  16. Realizing Serine/Threonine Ligation: Scope and Limitations and Mechanistic Implication Thereof

    Directory of Open Access Journals (Sweden)

    Clarence T. T. Wong

    2014-05-01

    Full Text Available Serine/Threonine ligation (STL has emerged as an alternative tool for protein chemical synthesis, bioconjugations as well as macrocyclization of peptides of various sizes. Owning to the high abundance of Ser/Thr residues in natural peptides and proteins, STL is expected to find a wide range of applications in chemical biology research. Herein, we have fully investigated the compatibility of the serine/threonine ligation strategy for X-Ser/Thr ligation sites, where X is any of the 20 naturally occurring amino acids. Our studies have shown that 17 amino acids are suitable for ligation, while Asp, Glu, and Lys are not compatible. Among the working 17 C-terminal amino acids, the retarded reaction resulted from the bulky β-branched amino acid (Thr, Val and Ile is not seen under the current ligation condition. We have also investigated the chemoselectivity involving the amino group of the internal lysine which may compete with the N-terminal Ser/Thr for reaction with the C-terminal salicylaldehyde (SAL ester aldehyde group. The result suggested that the free internal amino group does not adversely slow down the ligation rate.

  17. Template Directed Oligomer Ligation in Eutectic Phases in Water-Ice

    DEFF Research Database (Denmark)

    Dörr, Mark; Löffler, Philipp M. G.; Wieczorek, Rafal

    2011-01-01

    achieved, if small, activated, oligonucleotides are ligated on a template. A template directed ligation can lead to autocatalytic or cross- catalytic replication and thus maintain a certain pool of catalyitc species. Important for these processes is a destabilization of the formed douplex....../multiplex to overcome product inhibition. The latest results of our template directed ligation experiments in the eutectic ice phase are presented. Different activation strategies are compared and an outlook towards applications in molecular evolution and artifical cell systems (« protocells ») will be given. Figure 1....... (a) Reaction scheme of the condensation reaction of two oligoribonucleotides : The leaving group in this example is imidazole. (b) Illustration of a possible spatial arrangement of a template (15nt) directed ligation. The 7-mer is activated with imidazole at the 5' phosphate (apical moiety...

  18. Automatic error compensation in dc amplifiers

    International Nuclear Information System (INIS)

    Longden, L.L.

    1976-01-01

    When operational amplifiers are exposed to high levels of neutron fluence or total ionizing dose, significant changes may be observed in input voltages and currents. These changes may produce large errors at the output of direct-coupled amplifier stages. Therefore, the need exists for automatic compensation techniques. However, previously introduced techniques compensate only for errors in the main amplifier and neglect the errors induced by the compensating circuitry. In this paper, the techniques introduced compensate not only for errors in the main operational amplifier, but also for errors induced by the compensation circuitry. Included in the paper is a theoretical analysis of each compensation technique, along with advantages and disadvantages of each. Important design criteria and information necessary for proper selection of semiconductor switches will also be included. Introduced in this paper will be compensation circuitry for both resistive and capacitive feedback networks

  19. Fiber Amplifiers

    DEFF Research Database (Denmark)

    Rottwitt, Karsten

    2017-01-01

    The chapter provides a discussion of optical fiber amplifiers and through three sections provides a detailed treatment of three types of optical fiber amplifiers, erbium doped fiber amplifiers (EDFA), Raman amplifiers, and parametric amplifiers. Each section comprises the fundamentals including...... the basic physics and relevant in-depth theoretical modeling, amplifiers characteristics and performance data as a function of specific operation parameters. Typical applications in fiber optic communication systems and the improvement achievable through the use of fiber amplifiers are illustrated....

  20. Time course of collagen peak in bile duct-ligated rats

    OpenAIRE

    Tarcin, Orhan; Basaranoglu, Metin; Tahan, Veysel; Tahan, Gülgün; Sücüllü, Ilker; Yilmaz, Nevin; Sood, Gagan; Snyder, Ned; Hilman, Gilbert; Celikel, Cigdem; Tözün, Nurdan

    2011-01-01

    Abstract Background One of the most useful experimental fibrogenesis models is the "bile duct-ligated rats". Our aim was to investigate the quantitative hepatic collagen content by two different methods during the different stages of hepatic fibrosis in bile duct-ligated rats on a weekly basis. We questioned whether the 1-wk or 4-wk bile duct-ligated model is suitable in animal fibrogenesis trials. Methods Of the 53 male Wistar rats, 8 (Group 0) were used as a healthy control group. Bile duct...

  1. Menstrual Pattern following Tubal Ligation: A Historical Cohort Study

    Directory of Open Access Journals (Sweden)

    Shahideh Jahanian Sadatmahalleh

    2016-12-01

    Full Text Available Background: Tubal ligation (TL is recommended for women who have completed their family planning. The existence of the menstrual disorders following this procedure has been the subject of debate for decades. This study was conducted to identify the relationship between tubal ligation and menstrual disorders. Materials and Methods: A historical cohort study was carried out on 140 women undergoing tubal ligation (TL group and on 140 women using condom as the main contraceptive method (Non-TL group. They aged between 20 and 40 years and were selected from a health care center in Rudsar, Guilan Province, Iran, during 2013-2014. The two groups were comparable in demographic characteristics, obstetrical features and menstrual bleeding pattern using a routine questionnaire. A validated pictorial blood loss assessment chart (PBLAC was also used to measure the menstrual blood loss. Results: Women with TL had more menstrual irregularity than those without TL (24.3 vs. 10%, P=0.002. Women with TL had more polymenorrhea (9.3 vs. 1.4%, P=0.006, hypermenorrhea (12.1 vs. 2.1%, P=0.002, menorrhagia (62.9 vs. 22.1%, P<0.0001 and menometrorrhagia (15.7 vs. 3.6%, P=0.001 than those without TL. There is a significant difference in the PBLAC score between women with and without TL (P<0.0001. According to logistic regression, age odds ratio [(OR=1.08, confidence interval (CI:1.07-1.17, P=0.03], TL (OR=5.95, CI:3.45-10.26, P<0.0001 and cesarean section (OR=2.72, CI:1.49-4.97, P=0.001 were significantly associated with menorrhagia. Conclusion: We found significant differences in menstrual disorders between women with and without TL. Therefore, women should be informed by the health providers regarding the advantages and disadvantages of TL before the procedures.

  2. Milrinone use for hemodynamic instability in patent ductus arteriosus ligation.

    Science.gov (United States)

    Halliday, Matthew; Kavarana, Minoo; Ebeling, Myla; Kiger, James

    2017-03-01

    Determine if prophylactic milrinone improves cardiovascular or long-term clinical outcomes in preterm neonates who receive surgical patent ductus arteriosus (PDA) ligation. Retrospective review of 45 infants over a 4-year period that received a PDA ligation at one institution. Data were collected on morbidity and mortality outcomes for all infants as well as milrinone therapy perioperatively. Of the 45 infants that were studied 15 received milrinone in the perioperative period of PDA ligation and the remaining 30 infants did not receive milrinone. The use of milrinone showed no statistically significant improvement in acute markers of hemodynamic stability. There was also no statistically significant difference in morbidity and mortality outcomes in milrinone group compared to the non-milrinone group. Prophylactic milrinone use for premature infants following PDA ligation does not show a significant cardiovascular or long-term clinical benefit.

  3. Patent Ductus Arteriosus Ligation and Adverse Outcomes: Causality or Bias?

    Science.gov (United States)

    Weisz, Dany E.; McNamara, Patrick J.

    2014-01-01

    Observational studies have associated patent ductus arteriosus (PDA) ligation in preterm infants with increased chronic lung disease (CLD), retinopathy of prematurity, and neurodevelopmental impairment at long-term follow-up. Although the biological rationale for this association is incompletely understood, there is an emerging secular trend toward a permissive approach to the PDA. However, insufficient adjustment for postnatal, pre-ligation confounders, such as intraventricular hemorrhage and the duration and intensity of mechanical ventilation, suggests the presence of residual bias due to confounding by indication, and obliges caution in interpreting the ligation-morbidity relationship. A period of conservative management after failure of medical PDA closure may be considered to reduce the number of infants treated with surgery. Increased mortality and CLD in infants with persistent symptomatic PDA suggests that surgical ligation remains an important treatment modality for preterm infants. PMID:25024972

  4. Sphenopalatine Artery Ligation for Epistaxis: Factors Influencing Outcome and Impact of Timing of Surgery.

    Science.gov (United States)

    McDermott, Ailbhe M; O'Cathain, Eadaoin; Carey, Brian William; O'Sullivan, Peter; Sheahan, Patrick

    2016-03-01

    Sphenopalatine artery ligation is a commonly employed surgical intervention for control of posterior epistaxis unresponsive to nasal packing. The objective of the present study was to evaluate the outcome of sphenopalatine artery ligation for control of epistaxis at our institution and the impact of timing and other factors on outcome. Case series with chart review. Academic tertiary referral center. Case notes were reviewed for 45 consecutive patients undergoing sphenopalatine artery ligation for control of epistaxis between October 2008 and October 2014. Forty-one patients had nasal packing prior to sphenopalatine artery ligation, with 33 undergoing ≥2 packings. Postoperatively, 6 patients had rebleeding, which was treated with repacking (n = 4) and return to the operating room (n = 2). The overall success rate of sphenopalatine artery ligation was 87% (39 of 45). Rebleeding rate was not affected by concomitant septoplasty, anterior ethmoidal artery ligation, or postoperative nasal packing. Patients undergoing SPA ligation within the first 24 hours of admission had a significantly shorter hospital length of stay (3 vs 6 days, P = .02) and treatment cost (€5905 vs €10,001, P = .03). Length of stay was not influenced by sphenopalatine artery ligation after ≤1 nasal pack versus ≥2 packs. Timing of sphenopalatine artery ligation did not affect blood transfusion requirement (P = .84). Sphenopalatine artery ligation is an effective management strategy for surgical control of refractory epistaxis. Early timing of sphenopalatine artery ligation may lead to reductions in length of stay. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  5. Comparative Study of Compensatory Liver Regeneration in a Rat Model: Portal Vein Ligation Only versus Sequential Ligation of the Portal Vein and Hepatic Artery

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soo Young [Dept. of Pathology, Dongnam Institute of Radiological and Medical Sciences, Busan (Korea, Republic of); Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Lee, Byung Mo [Dept. of Surgery, Seoul Paik Hospital, Inje University College of Medicine, Seoul (Korea, Republic of)

    2013-04-15

    To compare the volume change and the regenerative capacity between portal vein ligation (embolization) (PVL) and heterochronous PVL with hepatic artery ligation (HAL) in a rodent model. The animals were separated into three groups: group I, ligation of the left lateral and median portal vein branches; group II, completion of PVL, followed by ligation of the same branches of the hepatic artery after 48 h; control group, laparotomy without ligation was performed. Five rats from each group were sacrificed on 1, 3, 5, and 7 days after the operation. Volume change measurement, liver function tests and immunohistochemical analysis were performed. The volume of the nonligated lobe between groups I and II was not significantly different by day 5 and day 7. Mean alanine aminotransferase and total bilirubin levels were significantly higher in group II, while the albumin level was higher in group I. Both c-kit- and MIB-5-positive cells used in the activity detection of regeneration were more prevalent in group I on day 1, 3, and 5, with statistical significance. There was no operation related mortality. PVL alone is safe and effective in compensatory liver regeneration. Performing both PVL and HAL does not confer any additional benefits.

  6. MicroRNA expression analysis and Multiplex ligation-dependent probe amplification in metastatic and non-metastatic uveal melanoma

    DEFF Research Database (Denmark)

    Larsen, Ann-Cathrine; Holst, Line; Kaczkowski, Bogumil

    2014-01-01

    Purpose: To determine the association of microRNA expression and chromosomal changes with metastasis and survival in uveal melanoma (UM). Methods: Thirty-six patients with UM were selected based on the metastatic status, and clinicopathological data were collected. Multiplex ligation-dependent pr...

  7. Protein chemical synthesis by α-ketoacid-hydroxylamine ligation.

    Science.gov (United States)

    Harmand, Thibault J; Murar, Claudia E; Bode, Jeffrey W

    2016-06-01

    Total chemical synthesis of proteins allows researchers to custom design proteins without the complex molecular biology that is required to insert non-natural amino acids or the biocontamination that arises from methods relying on overexpression in cells. We describe a detailed procedure for the chemical synthesis of proteins with the α-ketoacid-hydroxylamine (KAHA ligation), using (S)-5-oxaproline (Opr) as a key building block. This protocol comprises two main parts: (i) the synthesis of peptide fragments by standard fluorenylmethoxycarbonyl (Fmoc) chemistry and (ii) the KAHA ligation between fragments containing Opr and a C-terminal peptide α-ketoacid. This procedure provides an alternative to native chemical ligation (NCL) that could be valuable for the synthesis of proteins, particularly targets that do not contain cysteine residues. The ligation conditions-acidic DMSO/H2O or N-methyl-2-pyrrolidinone (NMP)/H2O-are ideally suited for solubilizing peptide segments, including many hydrophobic examples. The utility and efficiency of the protocol is demonstrated by the total chemical synthesis of the mature betatrophin (also called ANGPTL8), a 177-residue protein that contains no cysteine residues. With this protocol, the total synthesis of the betatrophin protein has been achieved in around 35 working days on a multimilligram scale.

  8. Click nucleic acid ligation: applications in biology and nanotechnology.

    Science.gov (United States)

    El-Sagheer, Afaf H; Brown, Tom

    2012-08-21

    Biochemical strategies that use a combination of synthetic oligonucleotides, thermostable DNA polymerases, and DNA ligases can produce large DNA constructs up to 1 megabase in length. Although these ambitious targets are feasible biochemically, comparable technologies for the chemical synthesis of long DNA strands lag far behind. The best available chemical approach is the solid-phase phosphoramidite method, which can be used to assemble DNA strands up to 150 bases in length. Beyond this point, deficiencies in the chemistry make it impossible to produce pure DNA. A possible alternative approach to the chemical synthesis of large DNA strands is to join together carefully purified synthetic oligonucleotides by chemical methods. Click ligation by the copper-catalyzed azide-alkyne (CuAAC) reaction could facilitate this process. In this Account, we describe the synthesis, characterization, and applications of oligonucleotides prepared by click ligation. The alkyne and azide oligonucleotide strands can be prepared by standard protocols, and the ligation reaction is compatible with a wide range of chemical modifications to DNA and RNA. We have employed click ligation to synthesize DNA constructs up to 300 bases in length and much longer sequences are feasible. When the resulting triazole linkage is placed in a PCR template, various DNA polymerases correctly copy the entire base sequence. We have also successfully demonstrated both in vitro transcription and rolling circle amplification through the modified linkage. This linkage has shown in vivo biocompatibility: an antibiotic resistance gene containing triazole linkages functions in E. coli . Using click ligation, we have synthesized hairpin ribozymes up to 100 nucleotides in length and a hammerhead ribozyme with the triazole linkage located at the substrate cleavage site. At the opposite end of the length scale, click-ligated, cyclic mini-DNA duplexes have been used as models to study base pairing. Cyclic duplexes have

  9. The clot thickens: an incompletely ligated left  atrial appendage

    Directory of Open Access Journals (Sweden)

    Merrill Thomas

    2018-05-01

    Full Text Available Our patient presented with known mechanical mitral valve endocarditis documented by 2D transesophageal echocardiogram (TOE from a recent hospitalization at an outside facility. On admission to our center, there was no prior knowledge of an incompletely ligated left atrial appendage (LAA according to patient- or family-reported history, review of outside records or the outside facility’s 2D TOE report. A 3D TOE performed at our center to assess her pathology, since a month had passed from her prior hospitalization, revealed a LAA ligation with evidence of communication to the left atrium and with clot present in the appendage. This case report highlights the common finding of incomplete closure of the LAA following surgical ligation, thus making it inadequate for stroke prevention in patients with atrial fibrillation, and that 3D TOE plays a valuable role in assessing the durability of LAA ligation.

  10. Protein-Templated Fragment Ligations-From Molecular Recognition to Drug Discovery.

    Science.gov (United States)

    Jaegle, Mike; Wong, Ee Lin; Tauber, Carolin; Nawrotzky, Eric; Arkona, Christoph; Rademann, Jörg

    2017-06-19

    Protein-templated fragment ligation is a novel concept to support drug discovery and can help to improve the efficacy of protein ligands. Protein-templated fragment ligations are chemical reactions between small molecules ("fragments") utilizing a protein's surface as a reaction vessel to catalyze the formation of a protein ligand with increased binding affinity. The approach exploits the molecular recognition of reactive small-molecule fragments by proteins both for ligand assembly and for the identification of bioactive fragment combinations. In this way, chemical synthesis and bioassay are integrated in one single step. This Review discusses the biophysical basis of reversible and irreversible fragment ligations and gives an overview of the available methods to detect protein-templated ligation products. The chemical scope and recent applications as well as future potential of the concept in drug discovery are reviewed. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Rubber band ligation and infrared photocoagulation for the outpatient treatment of hemorrhoidal disease.

    Science.gov (United States)

    Ricci, Maurício Pichler; Matos, Délcio; Saad, Sarhan Sydney

    2008-01-01

    To compare the results of rubber band ligation and infrared photocoagulation for the treatment of hemorrhoidal disease through the analysis of the incidence of complications after each treatment and respective success rate. Forty-eight patients with first, second or third degree hemorrhoidal disease were randomized to receive treatment with either rubber band ligation (n=23) or infrared photocoagulation (n=25). Each patient was assessed at 1 week and 4 week intervals after treatment. We compared the incidence of complications and efficiency of each treatment modality and Qui-square, Fisher's Exact Test and Student's t Test were used to statistical analysis. Bleeding occured in eight (34,7%) patients treated with rubber band ligation and in four (16,0%) after infrared photocoagulation (p=0,243). Thirteen (52,0%) patients felt pain during infrared photocoagulation and 9 (39,1%) after rubber band ligation (p=0,546). After rubber band ligation, 14 (60,8%) required medication for pain relief. One patient (4,0%) required medication after infrared photocoagulation (prubber band ligator and 1 (4,0%) treated with infrared photocoagulation had symptomatic mucosal ulcers. Perianal dermatitis occured in two (8,0%) patients treated with infrared photocoagulation and one patient (4,3%) was observed to have prolapsed thrombosed piles after rubber band ligation. One month after treatment, 17 of 23 patients treated with rubber band ligation (73,9%) and 18 of 25 patients treated with infrared photocoagulation were asymptomatic. Rubber band ligation treated bleeding and prolapse in 90,0% and 82,4% respectively. Infrared photocoagulation treats bleeding and prolapse in 93,7% and 87,5% respectively. Those differences are not significant. Rubber band ligation causes significantly more pain than infrared photocoagulation during the first week after the procedures and their success rate are not different after four weeks of treatment.

  12. 21 CFR 876.4400 - Hemorrhoidal ligator.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4400 Hemorrhoidal ligator. (a... of a ligature or band placed around the hemorrhoid. (b) Classification. Class II (performance...

  13. [Comparison of band ligation with sclerotherapy for the treatment of bleeding esophageal varices].

    Science.gov (United States)

    Ríos, Eddy; Sierralta, Armando; Abarzúa, Marigraciela; Bastías, Joaquín; Barra, María Inés

    2012-06-01

    Endoscopic band ligation is the treatment of choice for bleeding esophageal varices. However it is not clear if this procedure is associated with less early and late mortality than sclerotherapy. To assess rates of re-bleeding and mortality in cohorts of patients with bleeding esophageal varices treated with endoscopic injection or band ligation. Analysis of medical records and endoscopy reports of two cohorts of patients with bleeding esophageal varices, treated between 1990 and 2010. Of these, 54 patients were treated with sclerotherapy and 90 patients with band ligation. A third cohort of 116 patients that did not require endoscopic treatment, was included. The mean analyzed follow up period was 2.5 years (range 1-16). Collection of data was retrospective for patients treated with sclerotherapy and prospective for patients treated with band ligation. Rates of re-bleeding and medium term mortality were assessed. During the month ensuing the first endoscopic treatment, re-bleeding was recorded in 39 and 72% of patients treated with band ligation and sclerotherapy, respectively (p < 0.01). The relative risk of bleeding after band ligation was 0.53 (95% confidence limits 0.390.73). Death rates until the end of follow up were 20 and 48% among patients with treated with band ligation and sclerotherapy, respectively (p < 0.01), with a relative risk of dying for patients subjected to band ligation of 0.41 (95% confidence limits 0.25-0.68). Band ligation was associated with lower rates of re-bleeding and mortality in these cohorts of patients.

  14. Selective amplification and sequencing of cyclic phosphate-containing RNAs by the cP-RNA-seq method.

    Science.gov (United States)

    Honda, Shozo; Morichika, Keisuke; Kirino, Yohei

    2016-03-01

    RNA digestions catalyzed by many ribonucleases generate RNA fragments that contain a 2',3'-cyclic phosphate (cP) at their 3' termini. However, standard RNA-seq methods are unable to accurately capture cP-containing RNAs because the cP inhibits the adapter ligation reaction. We recently developed a method named cP-RNA-seq that is able to selectively amplify and sequence cP-containing RNAs. Here we describe the cP-RNA-seq protocol in which the 3' termini of all RNAs, except those containing a cP, are cleaved through a periodate treatment after phosphatase treatment; hence, subsequent adapter ligation and cDNA amplification steps are exclusively applied to cP-containing RNAs. cP-RNA-seq takes ∼6 d, excluding the time required for sequencing and bioinformatics analyses, which are not covered in detail in this protocol. Biochemical validation of the existence of cP in the identified RNAs takes ∼3 d. Even though the cP-RNA-seq method was developed to identify angiogenin-generating 5'-tRNA halves as a proof of principle, the method should be applicable to global identification of cP-containing RNA repertoires in various transcriptomes.

  15. Efficient DNA ligation in DNA–RNA hybrid helices by Chlorella virus DNA ligase

    Science.gov (United States)

    Lohman, Gregory J. S.; Zhang, Yinhua; Zhelkovsky, Alexander M.; Cantor, Eric J.; Evans, Thomas C.

    2014-01-01

    Single-stranded DNA molecules (ssDNA) annealed to an RNA splint are notoriously poor substrates for DNA ligases. Herein we report the unexpectedly efficient ligation of RNA-splinted DNA by Chlorella virus DNA ligase (PBCV-1 DNA ligase). PBCV-1 DNA ligase ligated ssDNA splinted by RNA with kcat ≈ 8 x 10−3 s−1 and KM DNA ligase produced only 5′-adenylylated DNA with a 20-fold lower kcat and a KM ≈ 300 nM. The rate of ligation increased with addition of Mn2+, but was strongly inhibited by concentrations of NaCl >100 mM. Abortive adenylylation was suppressed at low ATP concentrations (8, leading to increased product yields. The ligation reaction was rapid for a broad range of substrate sequences, but was relatively slower for substrates with a 5′-phosphorylated dC or dG residue on the 3′ side of the ligation junction. Nevertheless, PBCV-1 DNA ligase ligated all sequences tested with 10-fold less enzyme and 15-fold shorter incubation times than required when using T4 DNA ligase. Furthermore, this ligase was used in a ligation-based detection assay system to show increased sensitivity over T4 DNA ligase in the specific detection of a target mRNA. PMID:24203707

  16. Vitamin K1 attenuates bile duct ligation-induced liver fibrosis in rats.

    Science.gov (United States)

    Jiao, Kun; Sun, Quan; Chen, Baian; Li, Shengli; Lu, Jing

    2014-06-01

    Vitamin K1 is used as a liver protection drug for cholestasis-induced liver fibrosis in China, but the mechanism of vitamin K1's action in liver fibrosis is unclear. In this study, a model of liver fibrosis was achieved via bile duct ligation in rats. The rats were then injected with vitamin K1, and the levels of serum aspartate aminotransferase, alanine transaminase, total bilirubin and the fibrotic grade score, collagen content, the expressions of α-smooth muscle actin (SMA) and cytokeratin 19 (CK19) were measured on day 28 after ligation. The levels of the biochemical parameters, fibrotic score and collagen content were significantly reduced by treatment with vitamin K1 in bile duct-ligated rats. In addition, α-SMA and CK19 expression was significantly reduced by vitamin K1 treatment in bile duct-ligated rats. These results suggested that vitamin K1 may attenuate liver fibrosis by inhibiting hepatic stellate cell activation in bile duct-ligated rats.

  17. Friction behavior of self-ligating and conventional brackets with different ligature systems.

    Science.gov (United States)

    Szczupakowski, Alexandra; Reimann, Susanne; Dirk, Cornelius; Keilig, Ludger; Weber, Anna; Jäger, Andreas; Bourauel, Christoph

    2016-07-01

    Self-ligating brackets are widely believed to offer better clinical efficiency and, in particular, less friction. Thus, the goal of this in vitro investigation was to assess the friction behavior of different bracket/archwire/ligature combinations during simulated canine retraction. An important aspect of this work was to determine whether conventional bracket systems behave differently in passive or active self-ligating brackets used with a Slide™ ligature, an elastic ligature, or a steel ligature. Three conventional (Contour, Class One; Discovery(®), Dentaurum; Mystique MB, GAC) and six self-ligating (Carriere SL, Class One; Clarity™ SL, 3M Unitek; Damon3, Ormco; In-Ovation(®) C, GAC; Speed Appliance, Speed System™; QuicKlear(®), Forestadent(®)) bracket systems were analyzed. All brackets featured a 0.022″ slot (0.56 mm). Each conventional system was tested with a steel ligature (0.25 mm; Remanium(®), Dentaurum), an elastic ligature (1.3 mm in diameter; Dentalastics, Dentaurum), and a modified elastic ligature (Slide™; Leone(®)). Each combination was used with four archwires, including rectangular stainless steel (0.46 × 0.64 mm, 0.018 × 0.025″, Dentaurum), rectangular nickel-titanium with Teflon coating (0.46 × 0.64 mm, 0.018 × 0.025″, Forestadent(®)), round coaxial nickel-titanium (0.46 mm, 0.018″, Speed), and half-round/half-square (D-profile) stainless steel (0.46 mm, 0.018″, Speed). In the orthodontic measurement and simulation system (OMSS), retraction of a canine was simulated on a Frasaco model replicated in resin. Based on the force systems, the respective friction values were determined. For each combination of materials, five brackets of the same type were tested and five single measurements performed. Friction values were found to vary distinctly with the different combinations, modifiers being the ligature systems and the archwire types. Any significant friction differences between the steel-ligated, Slide™-ligated

  18. High-throughput determination of RNA structure by proximity ligation.

    Science.gov (United States)

    Ramani, Vijay; Qiu, Ruolan; Shendure, Jay

    2015-09-01

    We present an unbiased method to globally resolve RNA structures through pairwise contact measurements between interacting regions. RNA proximity ligation (RPL) uses proximity ligation of native RNA followed by deep sequencing to yield chimeric reads with ligation junctions in the vicinity of structurally proximate bases. We apply RPL in both baker's yeast (Saccharomyces cerevisiae) and human cells and generate contact probability maps for ribosomal and other abundant RNAs, including yeast snoRNAs, the RNA subunit of the signal recognition particle and the yeast U2 spliceosomal RNA homolog. RPL measurements correlate with established secondary structures for these RNA molecules, including stem-loop structures and long-range pseudoknots. We anticipate that RPL will complement the current repertoire of computational and experimental approaches in enabling the high-throughput determination of secondary and tertiary RNA structures.

  19. Banding ligation versus beta-blockers as primary prophylaxis in esophageal varices

    DEFF Research Database (Denmark)

    Gluud, Lise L; Klingenberg, Sarah; Nikolova, Dimitrinka

    2007-01-01

    To compare banding ligation versus beta-blockers as primary prophylaxis in patients with esophageal varices and no previous bleeding.......To compare banding ligation versus beta-blockers as primary prophylaxis in patients with esophageal varices and no previous bleeding....

  20. Hemothorax following Uncomplicated Endoscopic Variceal Sclerotherapy and Ligation for Esophageal Varices

    Directory of Open Access Journals (Sweden)

    Tomoko Ochiai

    2017-09-01

    Full Text Available Endoscopic variceal sclerotherapy and ligation are standard treatment modalities used for the management of esophageal varices. Reportedly, sclerotherapy and ligation are associated with complications such as hematuria, pulmonary thrombus formation, pleural effusion, renal dysfunction, and esophageal stenosis. However, hemothorax following sclerotherapy and ligation has not yet been reported. We treated a patient who presented with liver cirrhosis and polycythemia vera and later developed hemothorax following the above-mentioned procedures. An 86-year-old man diagnosed with liver cirrhosis due to chronic hepatitis type B and alcohol abuse underwent variceal sclerotherapy using ethanolamine oleate to treat his esophageal varices. Oozing from the esophageal varices continued even after the sclerotherapy procedure; therefore, we performed endoscopic variceal ligation. The patient developed left-sided hemothorax within 24 h after treatment of his varices, and an emergency thoracotomy was performed. A pulmonary ligament of the left lung was bulging and ripping because of mediastinal hematoma, and oozing was noted. Cessation of bleeding was noted after the laceration of the left pulmonary ligament had been sutured. Ours is the first case of hemothorax reported in a patient following an uncomplicated procedure of sclerotherapy and ligation.

  1. Heated oligonucleotide ligation assay (HOLA): an affordable single nucleotide polymorphism assay.

    Science.gov (United States)

    Black, W C; Gorrochotegui-Escalante, N; Duteau, N M

    2006-03-01

    Most single nucleotide polymorphism (SNP) detection requires expensive equipment and reagents. The oligonucleotide ligation assay (OLA) is an inexpensive SNP assay that detects ligation between a biotinylated "allele-specific detector" and a 3' fluorescein-labeled "reporter" oligonucleotide. No ligation occurs unless the 3' detector nucleotide is complementary to the SNP nucleotide. The original OLA used chemical denaturation and neutralization. Heated OLA (HOLA) instead uses a thermal stable ligase and cycles of denaturing and hybridization for ligation and SNP detection. The cost per genotype is approximately US$1.25 with two-allele SNPs or approximately US$1.75 with three-allele SNPs. We illustrate the development of HOLA for SNP detection in the Early Trypsin and Abundant Trypsin loci in the mosquito Aedes aegypti (L.) and at the a-glycerophosphate dehydrogenase locus in the mosquito Anopheles gambiae s.s.

  2. [Comparison of root resorption between self-ligating and conventional brackets using cone-beam CT].

    Science.gov (United States)

    Liu, Yun; Guo, Hong-ming

    2016-04-01

    To analyze the differences of root resorption between passive self-ligating and conventional brackets, and to determine the relationship between passive self-ligating brackets and root resorption. Fifty patients were randomly divided into 2 groups using passive self-ligating brackets or conventional straight wire brackets (0.022 system), respectively. Cone-beam CT was taken before and after treatment. The amount of external apical root resorption of maxillary incisors was measured on CBCT images. Student's t test was performed to analyze the differences of root apical resorption between the 2 groups with SPSS17.0 software package. No significant difference(P> 0.05) in root resorption of maxillary incisors was found between passive self-ligating brackets and conventional brackets. Passive self-ligating brackets and conventional brackets can cause root resorption, but the difference was not significant. Passive self-ligating brackets do not induce more root resorption.

  3. Synthesis of coumarin or ferrocene labeled nucleosides via Staudinger ligation

    Directory of Open Access Journals (Sweden)

    Kois Pavol

    2006-11-01

    Full Text Available Abstract Background Reaction of azides with triaryl phosphines under mild conditions gives iminophosphoranes which can react with almost any kind of electrophilic reagent, e.g. aldehydes/ketones to form imines or esters to form amides. This so-called Staudinger ligation has been employed in a wide range of applications as a general tool for bioconjugation including specific labeling of nucleic acids. Results A new approach for the preparation of labeled nucleosides via intermolecular Staudinger ligation is described. Reaction of azidonucleosides with triphenylphosphine lead to iminophosphorane intermediates, which react subsequently with derivatives of coumarin or ferrocene to form coumarin or ferrocene labeled nucleosides. Fluorescent properties of coumarin labeled nucleosides are determined. Conclusion New coumarin and ferrocene labeled nucleosides were prepared via intermolecular Staudinger ligation. This reaction joins the fluorescent coumarin and biospecific nucleoside to the new molecule with promising fluorescent and electrochemical properties. The isolated yields of products depend on the structure of azidonucleoside and carboxylic acids. A detailed study of the kinetics of the Staudinger ligation with nucleoside substrates is in progress.

  4. En bloc ligation of renal vessels is safe and reduces duration of surgery

    DEFF Research Database (Denmark)

    Azawi, Nessn Htum; Hult, Mariam Annalisa Skibsted; Dahl, Claus

    2016-01-01

    INTRODUCTION: Conventionally, individual ligation of the renal vessels with clips is performed during laparoscopic nephrectomy (LN). Concomitant ligation of the vessels is not a standard procedure due to an expected risk of stapler dysfunction and the development of arteriovenous fistulas (AVF......). Using the EndoGIA stapler 45/2.5 mm, we compared en bloc ligation with individual ligation during LN and nephroureterectomy (LNU) with a special focus on the development of AVF and technique safety. METHODS: This was a retrospective study of all patients undergoing LN or LNU at the Department of Urology......, Roskilde Hospital, Denmark, between January 2010 and April 2014. The follow-up period was minimum six months. RESULTS: A total of 228 patients underwent LN and 56 patients underwent LNU. In the LN group, 77 patients underwent en bloc ligation. The mean surgical time was significantly reduced to 89 minutes...

  5. The mechano-gated channel inhibitor GsMTx4 reduces the exercise pressor reflex in rats with ligated femoral arteries.

    Science.gov (United States)

    Copp, Steven W; Kim, Joyce S; Ruiz-Velasco, Victor; Kaufman, Marc P

    2016-05-01

    Mechanical and metabolic stimuli arising from contracting muscles evoke the exercise pressor reflex. This reflex is greater in a rat model of simulated peripheral arterial disease in which a femoral artery is chronically ligated than it is in rats with freely perfused femoral arteries. The role played by the mechanically sensitive component of the exaggerated exercise pressor reflex in ligated rats is unknown. We tested the hypothesis that the mechano-gated channel inhibitor GsMTx4, a relatively selective inhibitor of mechano-gated Piezo channels, reduces the exercise pressor reflex in decerebrate rats with ligated femoral arteries. Injection of 10 μg of GsMTx4 into the arterial supply of the hindlimb reduced the pressor response to Achilles tendon stretch (a purely mechanical stimulus) but had no effect on the pressor responses to intra-arterial injection of α,β-methylene ATP or lactic acid (purely metabolic stimuli). Moreover, injection of 10 μg of GsMTx4 into the arterial supply of the hindlimb reduced both the integrated pressor area (control 535 ± 21, GsMTx4 218 ± 24 mmHg·s; P reflex contributes to the exaggerated exercise pressor reflex during intermittent hindlimb muscle contractions in rats with ligated femoral arteries. Copyright © 2016 the American Physiological Society.

  6. The Effect of Various Ligation Methods on Friction in Sliding Mechanics

    Directory of Open Access Journals (Sweden)

    Amit Gupta

    2013-01-01

    Conclusion: Slide modules produce least friction followed by loose SS ligation, slick modules, regular modules, tight SS ligation and highest friction was produced by regular modules tied in a ′figure of 8′ pattern. Width of bracket had no influence on friction produced.

  7. Cholestasis progression effects on long-term memory in bile duct ligation rats

    Directory of Open Access Journals (Sweden)

    Nasrin Hosseini

    2014-01-01

    Full Text Available Background : There is evidence that cognitive functions are affected by some liver diseases such as cholestasis. Bile duct ligation induces cholestasis as a result of impaired liver function and cognition. This research investigates the effect of cholestasis progression on memory function in bile duct ligation rats. Materials and Methods: Male Wistar rats were randomly divided into five groups, which include: control group for BDL-7, control group for BDL-21, sham group (underwent laparotomy without bile duct ligation, BDL-7 group (7 days after bile duct ligation, and BDL-21 group (21 days after bile duct ligation. Step-through passive avoidance test was employed to examine memory function. In all groups, short-term (7 days after foot shock and long-term memories (21 days after foot shock were assessed. Results: Our results showed that liver function significantly decreased with cholestasis progression (P < 0.01. Also our findings indicated BDL-21 significantly impaired acquisition time (P < 0.05. Memory retrieval impaired 7 (P < 0.05 and 21 days (P < 0.001 after foot shock in BDL-7 and BDL-21 groups, respectively. Conclusion: Based on these findings, liver function altered in cholestasis and memory (short-term and long-term memory impaired with cholestasis progression in bile duct ligation rats. Further studies are needed to better insight the nature of progression of brain damage in cholestatic disease.

  8. Vocal cord paralysis post patent ductus arteriosus ligation surgery: risks and co-morbidities.

    Science.gov (United States)

    Rukholm, Gavin; Farrokhyar, Forough; Reid, Diane

    2012-11-01

    1. To determine the prevalence of left vocal cord paralysis (LVCP) post patent ductus arteriosus (PDA) ligation at a Tertiary Care Centre. 2. To identify risk factors associated with LVCP. 3. To identify co-morbidities associated with LVCP. 4. To determine the frequency of pre- and post-operative nasopharyngolaryngoscopic (NPL) examination in this patient population. Retrospective chart review of all infants who underwent PDA ligation surgery at a tertiary care academic hospital between July 2003 and July 2010. Data on patient age, gender, weight, method of PDA ligation, and results of NPL scoping were collected, as well as patient co-morbidities post PDA ligation. One hundred and fifteen patients underwent PDA ligation surgery. Four patients were excluded due to bilateral vocal cord paralysis. Of the remaining 111 patients, nineteen patients (17.1%) were found to have LVCP. Low birth weight was identified as a significant risk factor for LVCP (p=0.002). Gastroesophageal reflux was identified as a significant co-morbidity associated with LVCP post PDA ligation (p=0.002). Only 0.9% of patients were scoped pre-operatively, and 27.9% were scoped postoperatively. LVCP is associated with multiple morbidities. The authors strongly recommend routine post-operative scoping of all patients post PDA ligation surgery, and preoperative scoping when possible. A prospective study is warranted, in order to confirm the prevalence of LVCP as well as risk factors and associated co-morbidities. Crown Copyright © 2012. Published by Elsevier Ireland Ltd. All rights reserved.

  9. Corrosion behavior of self-ligating and conventional metal brackets

    Directory of Open Access Journals (Sweden)

    Lúcio Henrique Esmeraldo Gurgel Maia

    2014-04-01

    Full Text Available Objective: To test the null hypothesis that the aging process in self-ligating brackets is not higher than in conventional brackets. Methods: Twenty-five conventional (GN-3M/Unitek; GE-GAC; VE-Aditek and 25 self-ligating (SCs-3M/Unitek; INs-GAC; ECs-Aditek metal brackets from three manufacturers (n = 150 were submitted to aging process in 0.9% NaCl solution at a constant temperature of 37 ± 1ºC for 21 days. The content of nickel, chromium and iron ions in the solution collected at intervals of 7, 14 and 21 days was quantified by atomic absorption spectrophotometry. After the aging process, the brackets were analyzed by scanning electron microscopy (SEM under 22X and 1,000X magnifications. Results: Comparison of metal release in self-ligating and conventional brackets from the same manufacturer proved that the SCs group released more nickel (p < 0.05 than the GN group after 7 and 14 days, but less chromium (p < 0.05 after 14 days and less iron (p < 0.05 at the three experimental time intervals. The INs group released less iron (p < 0.05 than the GE group after 7 days and less nickel, chromium and iron (p < 0.05 after 14 and 21 days. The ECs group released more nickel, chromium and iron (p < 0.05 than the VE group after 14 days, but released less nickel and chromium (p < 0.05 after 7 days and less chromium and iron (p < 0.05 after 21 days. The SEM analysis revealed alterations on surface topography of conventional and self-ligating brackets. Conclusions: The aging process in self-ligating brackets was not greater than in conventional brackets from the same manufacturer. The null hypothesis was accepted.

  10. Operation amplifier

    NARCIS (Netherlands)

    Tetsuya, Saito; Nauta, Bram

    2008-01-01

    To provide an operation amplifier which improves power source voltage removal ratios while assuring phase compensation characteristics, and therefore can be realized with a small-scale circuit and low power consumption. SOLUTION: The operation amplifier comprises: a differential amplifier circuit 1;

  11. Generation of a pair of independently binding DNA aptamers in a single round of selection using proximity ligation.

    Science.gov (United States)

    Chumphukam, O; Le, T T; Piletsky, S; Cass, A E G

    2015-05-28

    The ability to rapidly generate a pair of aptamers that bind independently to a protein target would greatly extend their use as reagents for two site ('sandwich') assays. We describe here a method to achieve this through proximity ligation. Using lysozyme as a target we demonstrate that under optimal conditions such a pair of aptamers, with nanomolar affinities, can be generated in a single round.

  12. Infrared coagulation versus rubber band ligation in early stage hemorrhoids.

    Science.gov (United States)

    Gupta, P J

    2003-10-01

    The ideal therapy for early stages of hemorrhoids is always debated. Some are more effective but are more painful, others are less painful but their efficacy is also lower. Thus, comfort or efficacy is a major concern. In the present randomized study, a comparison is made between infrared coagulation and rubber band ligation in terms of effectiveness and discomfort. One hundred patients with second degree bleeding piles were randomized prospectively to either rubber band ligation (N = 54) or infrared coagulation (N = 46). Parameters measured included postoperative discomfort and pain, time to return to work, relief in incidence of bleeding, and recurrence rate. The mean age was 38 years (range 19-68 years). The mean duration of disease was 17.5 months (range 12 to 34 months). The number of male patients was double that of females. Postoperative pain during the first week was more intense in the band ligation group (2-5 vs 0-3 on a visual analogue scale). Post-defecation pain was more intense with band ligation and so was rectal tenesmus (P = 0.0059). The patients in the infrared coagulation group resumed their duties earlier (2 vs 4 days, P = 0.03), but also had a higher recurrence or failure rate (P = 0.03). Thus, we conclude that band ligation, although more effective in controlling symptoms and obliterating hemorrhoids, is associated with more pain and discomfort to the patient. As infrared coagulation can be conveniently repeated in case of recurrence, it could be considered to be a suitable alternative office procedure for the treatment of early stage hemorrhoids.

  13. Amplifier Distortion

    Science.gov (United States)

    Keeports, David

    2006-12-01

    By definition, a high fidelity amplifier's instantaneous output voltage is directly proportional to its instantaneous input voltage. While high fidelity is generally valued in the amplification of recorded music, nonlinearity, also known as distortion, is desirable in the amplification of some musical instruments. In particular, guitar amplifiers exploit nonlinearity to increase both the harmonic content and sustain of a guitar's sound. I will discuss how both modifications in sound result from saturation of triode tubes and transistors. Additionally, I will describe the difference in the symmetry of saturation curves for transistors and tubes and the reason why tube guitar amplifiers are generally considered to be superior to solid-state amplifiers. Finally, I will discuss attempts to use solid-state electronics to replicate the sound of tube amplifiers.

  14. Ligation of internal iliac arteries for control of pelvic haemorrhage.

    Directory of Open Access Journals (Sweden)

    Nandanwar Y

    1993-10-01

    Full Text Available This is a retrospective review of the internal iliac ligations (IAL done over a period of 3 years. Both gynaecological and obstetric cases were considered. A total of 46 ligations were performed. The additional treatment required was hysterectomy to control haemorrhage. Intra-and post-operative complications were noted. A comparative review of the effectiveness of IAL in different situations is done and alternative modalities of treatment are considered.

  15. Coronary ligation reduces maximum sustained swimming speed in Chinook salmon, Oncorhynchus tshawytscha

    DEFF Research Database (Denmark)

    Farrell, A P; Steffensen, J F

    1987-01-01

    The maximum aerobic swimming speed of Chinook salmon (Oncorhynchus tshawytscha) was measured before and after ligation of the coronary artery. Coronary artery ligation prevented blood flow to the compact layer of the ventricular myocardium, which represents 30% of the ventricular mass, and produced...

  16. Azobenzene Photoswitches for Staudinger-Bertozzi Ligation

    NARCIS (Netherlands)

    Szymanski, Wiktor; Wu, Bian; Poloni, Claudia; Janssen, Dick B.; Feringa, Ben L.

    2013-01-01

    A novel family of azobenzenes containing residues needed for aqueous Staudinger–Bertozzi ligation to azides was designed. The resulting photochromes show stable and reversible switching behavior in water, with a photostationary state (PSS) of up to 95:5 cis/trans. Applications in model systems

  17. Development of 650 MHz solid state RF amplifier for proton accelerator

    International Nuclear Information System (INIS)

    Jain, Akhilesh; Sharma, Deepak; Gupta, Alok; Tiwari, Ashish; Rao, Nageswar; Sekar, Vasanthi; Lad, M.; Hannurkar, P.R.; Gupta, P.D.

    2011-01-01

    Design and development of 30 kW high powers RF source at 650 MHz, using solid RF state technology, has been initiated at RRCAT. The indigenous technology development efforts will be useful for the proposed high power proton accelerators for SNS/ADS applications. In this 650 MHz amplifier scheme, 30 kW CW RF power will be generated using modular combination of 8 kW amplifier units. Necessary studies were carried out for device selection, choice of amplifier architecture and design of high power combiners and dividers. Presently RF amplifier delivering 250 W at 650 MHz has been fabricated and tested. Towards development of high power RF components, design and engineering prototyping of 16-port power combiner, directional coupler and RF dummy loads has been completed. The basic 8 kW amplifier unit is designed to provide power gain of 50 dB, bandwidth of 20 MHz and spurious response below 30 dB from fundamental signal. Based on the results of circuit simulation studies and engineering prototyping of amplifier module, two RF transistor viz. MRF3450 and MRF 61K were selected as solid state active devices. Impedance matching network in amplifier module is designed using balanced push pull configuration with transmission line BALUN. Due to high circulating current near drain side, metal clad RF capacitors were selected which helps in avoiding hot spot from output transmission path, ensuring continuous operation at rated RF power without damage to RF board. 350 W circulator is used to protect the RF devices from reflected power. Based on the prototype design and measured performance, one of these RF transistors will be selected to be used as workhorse for all amplifier modules. Two amplifier modules are mounted on water cooled copper heat-sink ensuring proper operating temperature for reliable and safe operation of amplifier. Also real time control system and data logger has been developed to provide DAQ and controls in each rack. For power combining and power measurement

  18. Isolation and characterization of portal branch ligation-stimulated Hmga2-positive bipotent hepatic progenitor cells

    International Nuclear Information System (INIS)

    Sakai, Hiroshi; Tagawa, Yoh-ichi; Tamai, Miho; Motoyama, Hiroaki; Ogawa, Shinichiro; Soeda, Junpei; Nakata, Takenari; Miyagawa, Shinichi

    2010-01-01

    Research highlights: → Hepatic progenitor cells were isolated from the portal branch-ligated liver of mice. → Portal branch ligation-stimulated hepatic progenitor cells (PBLHCs) express Hmga2. → PBLHCs have bidirectional differentiation capability in vitro. -- Abstract: Hepatic stem/progenitor cells are one of several cell sources that show promise for restoration of liver mass and function. Although hepatic progenitor cells (HPCs), including oval cells, are induced by administration of certain hepatotoxins in experimental animals, such a strategy would be inappropriate in a clinical setting. Here, we investigated the possibility of isolating HPCs in a portal branch-ligated liver model without administration of any chemical agents. A non-parenchymal cell fraction was prepared from the portal branch-ligated or non-ligated lobe, and seeded onto plates coated with laminin. Most of the cells died, but a small number were able to proliferate. These proliferating cells were cloned as portal branch ligation-stimulated hepatic cells (PBLHCs) by the limiting dilution method. The PBLHCs expressed cytokeratin19, albumin, and Hmga2. The PBLHCs exhibited metabolic functions such as detoxification of ammonium ions and synthesis of urea on Matrigel-coated plates in the presence of oncostatin M. In Matrigel mixed with type I collagen, the PBLHCs became rearranged into cystic and tubular structures. Immunohistochemical staining demonstrated the presence of Hmga2-positive cells around the interlobular bile ducts in the portal branch-ligated liver lobes. In conclusion, successful isolation of bipotent hepatic progenitor cell clones, PBLHCs, from the portal branch-ligated liver lobes of mice provides the possibility of future clinical application of portal vein ligation to induce hepatic progenitor cells.

  19. Effects of entanglement in an ideal optical amplifier

    Science.gov (United States)

    Franson, J. D.; Brewster, R. A.

    2018-04-01

    In an ideal linear amplifier, the output signal is linearly related to the input signal with an additive noise that is independent of the input. The decoherence of a quantum-mechanical state as a result of optical amplification is usually assumed to be due to the addition of quantum noise. Here we show that entanglement between the input signal and the amplifying medium can produce an exponentially-large amount of decoherence in an ideal optical amplifier even when the gain is arbitrarily close to unity and the added noise is negligible. These effects occur for macroscopic superposition states, where even a small amount of gain can leave a significant amount of which-path information in the environment. Our results show that the usual input/output relation of a linear amplifier does not provide a complete description of the output state when post-selection is used.

  20. Radiological study on the change of duct-ligated parotid gland

    International Nuclear Information System (INIS)

    Ohnishi, Takashi

    1994-01-01

    The change of the parotid gland with time following ligation of the main duct was investigated. The duct-ligated parotid gland in rabbit was examined by salivary gland scintigraphy with 99m Tc-pertechnetate ( 99m TcO 4 - ), sialography and microscopic observation. The third day after ligation of the main duct, the outward form of the parotid gland on the static scintigram was not well-defined. On the seventh day, 99m TcO 4 - accumulation was decreased slightly. On the 14th day, atrophy of the parotid gland occurred. The degree of atrophy produced by ligation increases as the duration of the ligation increases. On the 42nd day, the presence of the parotid gland was not recorded practically. The main duct was dilated on the third day. On the seventh day, the intraglandular ducts were bent and strictured. Disappearance of the peripheral duct and atrophy of the parotid gland parenchyma was observed. On microscopic observation, the intraglandular tributaries and the lumen were dilated on the third day. And the reticular fiber was observed that was irregularly formed in parts. The acinar cells were pressed by large and small dilated lumen on the seventh day. On the 14th day, the collagenous fiber around the acini and the duct was increased still more. In addition, fibrosis of the lobule interspace was observed. The degree of atrophy of the acini and lobule was increased maximally on the 42nd day. These results of the salivary gland scintigraphy closely connected with sialograms and microscopic findings. The parotid gland tissue decreases and changings of the duct system were indicated by these imaging methods in detail. (author)

  1. Infrared coagulation versus rubber band ligation in early stage hemorrhoids

    Directory of Open Access Journals (Sweden)

    P.J. Gupta

    2003-10-01

    Full Text Available The ideal therapy for early stages of hemorrhoids is always debated. Some are more effective but are more painful, others are less painful but their efficacy is also lower. Thus, comfort or efficacy is a major concern. In the present randomized study, a comparison is made between infrared coagulation and rubber band ligation in terms of effectiveness and discomfort. One hundred patients with second degree bleeding piles were randomized prospectively to either rubber band ligation (N = 54 or infrared coagulation (N = 46. Parameters measured included postoperative discomfort and pain, time to return to work, relief in incidence of bleeding, and recurrence rate. The mean age was 38 years (range 19-68 years. The mean duration of disease was 17.5 months (range 12 to 34 months. The number of male patients was double that of females. Postoperative pain during the first week was more intense in the band ligation group (2-5 vs 0-3 on a visual analogue scale. Post-defecation pain was more intense with band ligation and so was rectal tenesmus (P = 0.0059. The patients in the infrared coagulation group resumed their duties earlier (2 vs 4 days, P = 0.03, but also had a higher recurrence or failure rate (P = 0.03. Thus, we conclude that band ligation, although more effective in controlling symptoms and obliterating hemorrhoids, is associated with more pain and discomfort to the patient. As infrared coagulation can be conveniently repeated in case of recurrence, it could be considered to be a suitable alternative office procedure for the treatment of early stage hemorrhoids.

  2. Catalytic dehydroaromatization of n-alkanes by pincer-ligated iridium complexes

    Science.gov (United States)

    Ahuja, Ritu; Punji, Benudhar; Findlater, Michael; Supplee, Carolyn; Schinski, William; Brookhart, Maurice; Goldman, Alan S.

    2011-02-01

    Aromatic hydrocarbons are among the most important building blocks in the chemical industry. Benzene, toluene and xylenes are obtained from the high temperature thermolysis of alkanes. Higher alkylaromatics are generally derived from arene-olefin coupling, which gives branched products—that is, secondary alkyl arenes—with olefins higher than ethylene. The dehydrogenation of acyclic alkanes to give alkylaromatics can be achieved using heterogeneous catalysts at high temperatures, but with low yields and low selectivity. We present here the first catalytic conversion of n-alkanes to alkylaromatics using homogeneous or molecular catalysts—specifically ‘pincer’-ligated iridium complexes—and olefinic hydrogen acceptors. For example, the reaction of n-octane affords up to 86% yield of aromatic product, primarily o-xylene and secondarily ethylbenzene. In the case of n-decane and n-dodecane, the resulting alkylarenes are exclusively unbranched (that is, n-alkyl-substituted), with selectivity for the corresponding o-(n-alkyl)toluene.

  3. Effects of cholestasis on learning and locomotor activity in bile duct ligated rats.

    Science.gov (United States)

    Hosseini, Nasrin; Alaei, Hojjatallah; Nasehi, Mohammad; Radahmadi, Maryam; Mohammad Reza, Zarrindast

    2014-01-01

    Cognitive functions are impaired in patients with liver disease. Bile duct ligation causes cholestasis that impairs liver function. This study investigated the impact of cholestasis progression on the acquisition and retention times in the passive avoidance test and on the locomotor activity of rats. Cholestasis was induced in male Wistar rats by ligating the main bile duct. Locomotor activity, learning and memory were assessed by the passive avoidance learning test at day 7, day 14, and day 21 post-bile duct ligation. The serum levels of bilirubin, alanine aminotransferase, and alkaline phosphatase were measured. The results showed that acquisition time and locomotor activity were not affected at day 7 and day 14, but they were significantly (P locomotor activity were impaired at 21 days after bile duct ligation following the progression of cholestasis.

  4. Amplifiers dedicated for large area SiC photodiodes

    Science.gov (United States)

    Doroz, P.; Duk, M.; Korwin-Pawlowski, M. L.; Borecki, M.

    2016-09-01

    Large area SiC photodiodes find applications in optoelectronic sensors working at special conditions. These conditions include detection of UV radiation in harsh environment. Moreover, the mentioned sensors have to be selective and resistant to unwanted signals. For this purpose, the modulation of light at source unit and the rejection of constant current and low frequency component of signal at detector unit are used. The popular frequency used for modulation in such sensor is 1kHz. The large area photodiodes are characterized by a large capacitance and low shunt resistance that varies with polarization of the photodiode and can significantly modify the conditions of signal pre-amplification. In this paper two pre-amplifiers topology are analyzed: the transimpedance amplifier and the non-inverting voltage to voltage amplifier with negative feedback. The feedback loops of both pre-amplifiers are equipped with elements used for initial constant current and low frequency signals rejections. Both circuits are analyzed and compared using simulation and experimental approaches.

  5. Self-ligating versus conventional metallic brackets on Streptococcus mutans retention: A systematic review.

    Science.gov (United States)

    Longoni, Juliano N; Lopes, Beatriz M; Freires, Irlan A; Dutra, Kamile L; Franco, Ademir; Paranhos, Luiz R

    2017-01-01

    The present study aimed to review the literature systematically and assess comparatively whether self-ligating metallic brackets accumulate less Streptococcus mutans biofilm than conventional metallic brackets. The systematic search was performed following PRISMA guidelines and registration in PROSPERO. Seven electronic databases (Google Scholar, LILACS, Open Grey, PubMed, SciELO, ScienceDirect, and Scopus) were consulted until April 2016, with no restriction of language and time of publication. Only randomized clinical studies verifying S. mutans colonization in metallic brackets (self-ligating and conventional) were included. All steps were performed independently by two operators. The search resulted in 546 records obtained from the electronic databases. Additionally, 216 references obtained from the manual search of eligible articles were assessed. Finally, a total of 5 studies were included in the qualitative synthesis. In 1 study, the total bacterial count was not different among self-ligating and conventional brackets, whereas in 2 studies the amount was lower for self-ligating brackets. Regarding the specific count of S. mutans , 2 studies showed less accumulation in self-ligating than in conventional brackets. Based on the limited evidence, self-ligating metallic brackets accumulate less S. mutans than conventional ones. However, these findings must be interpreted in conjunction with particularities individual for each patient - such as hygiene and dietary habits, which are components of the multifactorial environment that enables S. Mutans to proliferate and keep retained in the oral cavity.

  6. Factors Promoting Tubal Ligation in Females Presenting to Tertiary Care Centers

    Directory of Open Access Journals (Sweden)

    Hammad Ali Qazi

    2009-09-01

    Full Text Available Objective: Despite development of new contraceptive methods, sterilization remained the most widely used method. Our objective was to determine the factors contributing to decision making for tubal ligation in females.Materials and methods: A cross sectional study was conducted in Jinnah Post graduate Medical Centre (JPMC between March - November 2008. About 505 Females using contraceptive measures were consecutively included. Those having any severe debilitating disease and unfamiliar with “urdu” language were excluded. Three trained co researchers conducted structured interviews to determine the frequency and factors associated with tubal ligation.Results: The final multiple logistic regression showed illiteracy [AOR 2.91 95% CI 1.53-5.53], number of children < 3 [AOR 6.15 95% CI 2.61-14.50], age of women < 30 [AOR 0.12 95% CI 0.06-0.22] years and information gained through health worker [AOR 3.04 95% CI 1.60-5.80] to be statistically significant.Conclusion: This highlights tubal ligation was more common in uneducated women of age > 35 years having <3 children. The most common means of promoting tubal ligation was information gained through health workers.

  7. Catecholamine-resistant hypotension and myocardial performance following patent ductus arteriosus ligation.

    LENUS (Irish Health Repository)

    Noori, S

    2014-08-14

    Objective:We performed a multicenter study of preterm infants, who were about to undergo patent ductus arteriosus ligation, to determine whether echocardiographic indices of impaired myocardial performance were associated with subsequent development of catecholamine-resistant hypotension following ligation.Study Design:A standardized treatment approach for hypotension was followed at each center. Infants were considered to have catecholamine-resistant hypotension if their dopamine infusion was >15 μg kg(-1)min(-1). Echocardiograms and cortisol measurements were obtained between 6 and 14 h after the ligation (prior to the presence of catecholamine-resistant hypotension).Result:Forty-five infants were enrolled, 10 received catecholamines (6 were catecholamine-responsive and 4 developed catecholamine-resistant hypotension). Catecholamine-resistant hypotension was not associated with decreased preload, shortening fraction or ventricular output. Infants with catecholamine-resistant hypotension had significantly lower levels of systemic vascular resistance and postoperative cortisol concentration.Conclusion:We speculate that low cortisol levels and impaired vascular tone may have a more important role than impaired cardiac performance in post-ligation catecholamine-resistant hypotension.Journal of Perinatology advance online publication, 14 August 2014; doi:10.1038\\/jp.2014.151.

  8. Evaluation of frictional forces of polycarbonate self-ligating brackets.

    Science.gov (United States)

    Fernandes, Daniel J; Miguel, José Augusto M; Quintão, Catia C A; Elias, Carlos N

    2010-01-01

    To evaluate the frictional forces generated by ceramic- (Opal, Ultradent) and glass-fiber-reinforced polycarbonate self-ligating brackets (Oyster, Gestenco) and compare the effectiveness of these ligatureless systems with glass-fiber-reinforced polycarbonate conventional brackets (Blonde, Gestenco). The hypothesis is that there is no difference between frictional forces generated by ceramic- and glass-fiber-reinforced polycarbonate self-ligating and glass-fiber-reinforced polycarbonate conventional brackets. Twelve preadjusted 0.022 3 0.028-inch maxillary canine brackets were tested, divided into three groups: Opal, Oyster, and Blonde. Frictional tests were conducted with the Emic DL 10000 testing machine with a 20 N loadcell for 40 seconds at a 0.5 cm/min speed. Each bracket-wire combination was tested five times. The data generated were analyzed by parametric analysis of variance (one-way ANOVA) and Bonferroni tests. Analysis of variance indicated significant differences for the three groups (Pfrictional forces of the Oyster glass-fiber-reinforced polycarbonate self-ligating brackets were significantly lower (37.0 ± 8.9 cN) than those of the Opal ceramic-reinforced polycarbonate self-ligating brackets (49.5 ± 10.1 cN), while the Blonde glass-fiber-reinforced conventional bracket frictional forces were 105.8 ± 6.4 cN. Oyster glass-fiber-reinforced polycarbonate brackets produced less friction than Opal ceramic-reinforced polycarbonate brackets. The polycarbonate ligatureless system showed significantly lower frictional forces compared to Blonde conventional polycarbonate brackets tied with elastomeric ligatures. The study rejected the initial hypothesis because there are significant differences of frictional forces among the tested systems. © 2010 BY QUINTESSENCE PUBLISHING CO, INC.

  9. The effect of ligation method on friction in sliding mechanics.

    Science.gov (United States)

    Hain, Max; Dhopatkar, Ashish; Rock, Peter

    2003-04-01

    During orthodontic tooth movement with the preadjusted edgewise system, friction generated at the bracket/archwire interface tends to impede the desired movement. The method of ligation is an important contributor to this frictional force. This in vitro study investigated the effect of ligation method on friction and evaluated the efficacy of the new slick elastomeric modules from TP Orthodontics (La Porte, Ind), which are claimed to reduce friction at the module/wire interface. Slick modules were compared with regular nonslick modules, stainless steel ligatures, and the SPEED self-ligating bracket system (Strite Industries, Cambridge, Ontario, Canada). The effect of using slick modules with metal-reinforced ceramic (Clarity, 3M Unitek, Monrovia, Calif) and miniature brackets (Minitwin, 3M Unitek) was also examined. Results showed that, when considering tooth movement along a 0.019 x 0.025-in stainless steel archwire, saliva-lubricated slick modules can reduce static friction at the module/archwire interface by up to 60%, regardless of the bracket system. The SPEED brackets produced the lowest friction compared with the 3 other tested bracket systems when regular modules were used. The use of slick modules, however, with all of the ligated bracket types tested significantly reduced friction to below the values recorded in the SPEED groups. Loosely tied stainless steel ligatures were found to generate the least friction.

  10. Dispersion-Engineered Traveling Wave Kinetic Inductance Parametric Amplifier

    Science.gov (United States)

    Zmuidzinas, Jonas (Inventor); Day, Peter K. (Inventor)

    2014-01-01

    A traveling wave kinetic inductance parametric amplifier comprises a superconducting transmission line and a dispersion control element. The transmission line can include periodic variations of its dimension along its length. The superconducting material can include a high normal state resistivity material. In some instances the high normal state resistivity material includes nitrogen and a metal selected from the group consisting of titanium, niobium and vanadium. The traveling wave kinetic inductance parametric amplifier is expected to exhibit a noise temperature below 100 mK/GHz.

  11. Gene assembly via one-pot chemical ligation of DNA promoted by DNA nanostructures

    DEFF Research Database (Denmark)

    Manuguerra, Ilenia; Croce, Stefano; El-Sagheer, Afaf H.

    2018-01-01

    Current gene synthesis methods are driven by enzymatic reactions. Here we report the one-pot synthesis of a chemically-ligated gene from 14 oligonucleotides. The chemical ligation benefits from the highly efficient click chemistry approach templated by DNA nanostructures, and produces modified DNA...

  12. Total synthesis of cytochrome b562 by native chemical ligation using a removable auxiliary

    Science.gov (United States)

    Low, Donald W.; Hill, Michael G.; Carrasco, Michael R.; Kent, Stephen B. H.; Botti, Paolo

    2001-01-01

    We have completed the total chemical synthesis of cytochrome b562 and an axial ligand analogue, [SeMet7]cyt b562, by thioester-mediated chemical ligation of unprotected peptide segments. A novel auxiliary-mediated native chemical ligation that enables peptide ligation to be applied to protein sequences lacking cysteine was used. A cleavable thiol-containing auxiliary group, 1-phenyl-2-mercaptoethyl, was added to the α-amino group of one peptide segment to facilitate amide bond-forming ligation. The amine-linked 1-phenyl-2-mercaptoethyl auxiliary was stable to anhydrous hydrogen fluoride used to cleave and deprotect peptides after solid-phase peptide synthesis. Following native chemical ligation with a thioester-containing segment, the auxiliary group was cleanly removed from the newly formed amide bond by treatment with anhydrous hydrogen fluoride, yielding a full-length unmodified polypeptide product. The resulting polypeptide was reconstituted with heme and folded to form the functional protein molecule. Synthetic wild-type cyt b562 exhibited spectroscopic and electrochemical properties identical to the recombinant protein, whereas the engineered [SeMet7]cyt b562 analogue protein was spectroscopically and functionally distinct, with a reduction potential shifted by ≈45 mV. The use of the 1-phenyl-2-mercaptoethyl removable auxiliary reported here will greatly expand the applicability of total protein synthesis by native chemical ligation of unprotected peptide segments. PMID:11390992

  13. Auto-Zero Differential Amplifier

    Science.gov (United States)

    Quilligan, Gerard T. (Inventor); Aslam, Shahid (Inventor)

    2017-01-01

    An autozero amplifier may include a window comparator network to monitor an output offset of a differential amplifier. The autozero amplifier may also include an integrator to receive a signal from a latched window comparator network, and send an adjustment signal back to the differential amplifier to reduce an offset of the differential amplifier.

  14. Performance analysis of best relay selection scheme for amplify-and-forward cooperative networks in identical Nakagami-m channels

    KAUST Repository

    Hussain, Syed Imtiaz

    2010-06-01

    In cooperative communication networks, the use of multiple relays between the source and the destination was proposed to increase the diversity gain. Since the source and all the relays must transmit on orthogonal channels, multiple relay cooperation is considered inefficient in terms of channel resources and bandwidth utilization. To overcome this problem, the concept of best relay selection was recently proposed. In this paper, we analyze the performance of the best relay selection scheme for a cooperative network with multiple relays operating in amplify-and-forward (AF) mode over identical Nakagami-m channels using exact source-relay-destination signal to noise ratio (SNR) expression. We derive accurate closed form expressions for various system parameters including probability density function (pdf) of end-to-end SNR, average output SNR, average probability of bit error and average channel capacity. T he analytical results are verified through extensive simulations. It is shown that the best relay selection scheme performs better than the regular all relay cooperation.

  15. Transcatheter closure of re-canalized patent ductus arteriosus after surgical ligation

    International Nuclear Information System (INIS)

    Zhang Qingqiao; Jiang Shiliang; Huang Lianjun; Zhao Shihua; Zheng Hong; Ling Jian; Jin Jinglin; Xu Zhongying; Xie Ruolan; Dai Ruping

    2002-01-01

    Objective: To evaluate the effectiveness of transcatheter closure of re-canalized patent ductus arteriosus (PDA) after surgical ligation. Methods: Between June 1995 and November 2000, 14 patients (5 male, 9 female) with re-canalized PDA after surgical ligation underwent transcatheter closure, their median age was 13 years (range 4 to 48 years). The time between surgical ligation and the interventional procedure ranged from one month to twenty-two years. Implantations of Amplatzer duct occluder and Rashkind occluder were performed trans-venously. Cook coil occlusions was performed trans-arterially. Follow-up with X-ray radiograph and echocardiography was made 24 hours, 1, 3, 6 months, and more than 1 year after the procedure. Results: Twelve PDAs were of funnel shape, and the remaining two PDAs were of tubular shape. The median minimum diameter of re-canalized PDA after ligation was 4 mm (range 1 to 8 mm). Aortograms ten minutes after closure showed complete closure and trivial residual shunt in 11 and 3 patients, respectively. The technical success rate was 100%, and there were no complications. Echocardiography showed complete closure in all patients within 24 hours. All patients were discharged in one to two days after the procedure. At a follow-up of one to eighteen months in ten patients, there were no migration of devices and residual PDA. Conclusion: Transcatheter closure using Amplatzer duct occluder, coil (Cook company or Pfm company) and Rashkind occluder was an effective method for patients with re-canalized PDA after surgical ligation. It may be an alternative to second surgery owing to its safety, reliability, min-invasiveness, and short hospitalization

  16. Transcatheter closure of re-canalized patent ductus arteriosus after surgical ligation

    Energy Technology Data Exchange (ETDEWEB)

    Qingqiao, Zhang; Shiliang, Jiang; Lianjun, Huang; Shihua, Zhao; Hong, Zheng; Jian, Ling; Jinglin, Jin; Zhongying, Xu; Ruolan, Xie; Ruping, Dai [Chinese Academy of Medical Science, Beijing Union Medical College, Beijing (China). Cardiovascular Inst. and Fuwai Hospital, Dept. of Radiology

    2002-02-01

    Objective: To evaluate the effectiveness of transcatheter closure of re-canalized patent ductus arteriosus (PDA) after surgical ligation. Methods: Between June 1995 and November 2000, 14 patients (5 male, 9 female) with re-canalized PDA after surgical ligation underwent transcatheter closure, their median age was 13 years (range 4 to 48 years). The time between surgical ligation and the interventional procedure ranged from one month to twenty-two years. Implantations of Amplatzer duct occluder and Rashkind occluder were performed trans-venously. Cook coil occlusions was performed trans-arterially. Follow-up with X-ray radiograph and echocardiography was made 24 hours, 1, 3, 6 months, and more than 1 year after the procedure. Results: Twelve PDAs were of funnel shape, and the remaining two PDAs were of tubular shape. The median minimum diameter of re-canalized PDA after ligation was 4 mm (range 1 to 8 mm). Aortograms ten minutes after closure showed complete closure and trivial residual shunt in 11 and 3 patients, respectively. The technical success rate was 100%, and there were no complications. Echocardiography showed complete closure in all patients within 24 hours. All patients were discharged in one to two days after the procedure. At a follow-up of one to eighteen months in ten patients, there were no migration of devices and residual PDA. Conclusion: Transcatheter closure using Amplatzer duct occluder, coil (Cook company or Pfm company) and Rashkind occluder was an effective method for patients with re-canalized PDA after surgical ligation. It may be an alternative to second surgery owing to its safety, reliability, min-invasiveness, and short hospitalization.

  17. Identification, genetic localization, and allelic diversity of selectively amplified microsatellite polymorphic loci in lettuce and wild relatives (Lactuca spp.).

    Science.gov (United States)

    Witsenboer, H; Michelmore, R W; Vogel, J

    1997-12-01

    Selectively amplified microsatellite polymorphic locus (SAMPL) analysis is a method of amplifying microsatellite loci using generic PCR primers. SAMPL analysis uses one AFLP primer in combination with a primer complementary to microsatellite sequences. SAMPL primers based on compound microsatellite sequences provided the clearest amplification patterns. We explored the potential of SAMPL analysis in lettuce to detect PCR-based codominant microsatellite markers. Fifty-eight SAMPLs were identified and placed on the genetic map. Seventeen were codominant. SAMPLs were dispersed with RFLP markers on 11 of the 12 main linkage groups in lettuce, indicating that they have a similar genomic distribution. Some but not all fragments amplified by SAMPL analysis were confirmed to contain microsatellite sequences by Southern hybridization. Forty-five cultivars of lettuce and five wild species of Lactuca were analyzed to determine the allelic diversity for codominant SAMPLs. From 3 to 11 putative alleles were found for each SAMPL; 2-6 alleles were found within Lactuca sativa and 1-3 alleles were found among the crisphead genotypes, the most genetically homogeneous plant type of L. sativa. This allelic diversity is greater than that found for RFLP markers. Numerous new alleles were observed in the wild species; however, there were frequent null alleles. Therefore, SAMPL analysis is more applicable to intraspecific than to interspecific comparisons. A phenetic analysis based on SAMPLs resulted in a dendrogram similar to those based on RFLP and AFLP markers.

  18. Debris and friction of self-ligating and conventional orthodontic brackets after clinical use.

    Science.gov (United States)

    Araújo, Raíssa Costa; Bichara, Lívia Monteiro; Araujo, Adriana Monteiro de; Normando, David

    2015-07-01

    To compare the degree of debris and friction of conventional and self-ligating orthodontic brackets before and after clinical use. Two sets of three conventional and self-ligating brackets were bonded from the first molar to the first premolar in eight individuals, for a total of 16 sets per type of brackets. A passive segment of 0.019 × 0.025-inch stainless steel archwire was inserted into each group of brackets. Frictional force and debris level were evaluated as received and after 8 weeks of intraoral exposure. Two-way analysis of variance and Wilcoxon signed-rank test were applied at P brackets (P brackets showed a higher amount of debris compared with the conventional brackets. The frictional force in conventional brackets was significantly higher when compared with self-ligating brackets before clinical use (P brackets, when exposed to the intraoral environment, showed a significant increase in frictional force during the sliding mechanics. Debris accumulation was higher for the self-ligating system.

  19. Ectopic pregnancy after two times tubal ligation: a case report

    Directory of Open Access Journals (Sweden)

    Farideh Keypour

    2013-06-01

    Full Text Available Background: Tubal sterilization is the permanent and effective contraception method. This can be performed at any time, but at least half are performed in conjunction with cesarean or vaginal delivery and are termed puerperal. The most complication after tubal ligation is ectopic pregnancy. Ectopic pregnancy is the leading cause of maternal death in first trimester.Case presentation: We present a 33 years old woman gravida5, para4, all normal vaginal delivery, presented with complaints of delayed menstrual period, pelvic pain and spotting. She underwent tubal ligation for two times. For the first time she had puerperal Pomeroy tubal sterilization after third child delivery. Intra uterine pregnancy occurred three years later. One day after vaginal delivery of fourth child, she underwent post partum tubal ligation with the Parkland method. Tubal pregnancy occurred nine months later. Physical examination identified acute abdomen. Pelvic ultrasound showed no gestational sac in uterine cavity. The sac with fetal pole was in right adnexa. Beta-HCG was 2840mIU/ml. She underwent laparotomy. Surgical management included salpingectomy with cornual resection in both sides. The surgery identified Ectopic pregnancy.Conclusion: Any symptoms of pregnancy in a woman after tubal ligation must be investigated; an ectopic pregnancy should be excluded. Ectopic pregnancy must be considered, in any woman with lower abdominal pain, missed period and vaginal bleed-ing. Conception after tubal sterilization can be explained by fistula formation and re-canalization of fallopian tube.

  20. Ergonomic varicocele ligation: laparoscopic intracorporeal knot-tying

    African Journals Online (AJOL)

    Department of Pediatric Surgery, Sevket Yilmaz Education and Research. Hospital, Bursa, Turkey ... laparoscopic approach to varicocelectomy has been the high associated ... bilateral varicoceles, a 3 mm trocar was placed at the right. McBurney's .... open-high or subinguinal ligation (microsurgical), laparo- scopic methods ...

  1. MR imaging of salivary glands after ductal ligation and stimulation by pilocarpine

    International Nuclear Information System (INIS)

    Patronas, N.J.; Tsuchimoch, M.; Webber, R.; Ruttimann, U.; Fox, P.; Bacher, J.; Schellinger, D.

    1988-01-01

    This paper presents an assessment of the usefulness of MR imaging in pathologic conditions of the salivary gland. The authors performed MR imaging in six dogs after ductal ligation on one side, followed by secretory stimulation with intraperitoneal injection of pilocarpine (5 mg/kg). On the images obtained after ductal ligation and before stimulation, there was no significant change in the signal intensity on either side. After injection of pilocarpine, however, T2-weighted images showed an obvious increase in signal intensity of the ligated gland in every instance. Their results indicate that MR images obtained after pilocarpine stimulation will be useful to study patients with ductal obstruction and that they may provide an objective basis for a noninvasive diagnostic test for unilateral stenosis

  2. Association of Patent Ductus Arteriosus Ligation With Death or Neurodevelopmental Impairment Among Extremely Preterm Infants

    Science.gov (United States)

    Mirea, Lucia; Rosenberg, Erin; Jang, Maximus; Ly, Linh; Church, Paige T.; Kelly, Edmond; Kim, S. Joseph; Jain, Amish; McNamara, Patrick J.; Shah, Prakesh S.

    2017-01-01

    Importance Observational studies have associated patent ductus arteriosus (PDA) ligation among preterm infants with adverse neonatal outcomes and neurodevelopmental impairment in early childhood, with a resultant secular trend away from surgical treatment. However, to our knowledge, studies have inadequately addressed sources of residual bias, including survival bias and major neonatal morbidities arising before exposure to ligation. Objective Evaluate the association between PDA ligation vs medical management and neonatal and neurodevelopmental outcomes. Design, Setting, and Participants This retrospective cohort study of preterm infants younger than 28 weeks gestational age born between January 1, 2006, and December 31, 2012, with clinical and echocardiography diagnoses of hemodynamically significant PDA was conducted at 3 tertiary neonatal intensive care units and affiliated follow-up programs. Exposure Surgical ligation vs medical management. Main Outcomes and Measures The primary outcome was a composite of death or neurodevelopmental impairment (NDI) at 18 to 24 months corrected age. Secondary outcomes included death before discharge, NDI, moderate-severe chronic lung disease, and severe retinopathy of prematurity. Multivariable logistic regression analysis was used to adjust for perinatal and postnatal confounders. Results Of 754 infants with hemodynamically significant PDA (mean [standard deviation] gestational age 25.7 [1.2] weeks and birth weight 813 [183] grams), 184 (24%) underwent ligation. Infants who underwent ligation had a higher frequency of morbidities before PDA closure, including sepsis, necrotizing enterocolitis, and a dependence on mechanical ventilation. After adjusting for perinatal characteristics and preligation morbidities, there was no difference in the odds of death or NDI (adjusted odds ratio (aOR), 0.83; 95% CI, 0.52-1.32), NDI (aOR, 1.27; 95% CI, 0.78-2.06), chronic lung disease (aOR, 1.36; 95% CI, 0.78-2.39) or severe retinopathy of

  3. Rapid production of functionalized recombinant proteins: marrying ligation independent cloning and in vitro protein ligation.

    Science.gov (United States)

    Kushnir, Susanna; Marsac, Yoann; Breitling, Reinhard; Granovsky, Igor; Brok-Volchanskaya, Vera; Goody, Roger S; Becker, Christian F W; Alexandrov, Kirill

    2006-01-01

    Functional genomics and proteomics have been very active fields since the sequencing of several genomes was completed. To assign a physiological role to the newly discovered coding genes with unknown function, new generic methods for protein production, purification, and targeted functionalization are needed. This work presents a new vector, pCYSLIC, that allows rapid generation of Escherichia coli expression constructs via ligation-independent cloning (LIC). The vector is designed to facilitate protein purification by either Ni-NTA or GSH affinity chromatography. Subsequent proteolytic removal of affinity tags liberates an N-terminal cysteine residue that is then used for covalent modification of the target protein with different biophysical probes via protein ligation. The described system has been tested on 36 mammalian Rab GTPases, and it was demonstrated that recombinant GTPases produced with pCYSLIC could be efficiently modified with fluorescein or biotin in vitro. Finally, LIC was compared with the recently developed In-Fusion cloning method, and it was demonstrated that In-Fusion provides superior flexibility in choice of expression vector. By the application of In-Fusion cloning Cys-Rab6A GTPase with an N-terminal cysteine residue was generated employing unmodified pET30a vector and TVMV protease.

  4. Portable musical instrument amplifier

    Science.gov (United States)

    Christian, David E.

    1990-07-24

    The present invention relates to a musical instrument amplifier which is particularly useful for electric guitars. The amplifier has a rigid body for housing both the electronic system for amplifying and processing signals from the guitar and the system's power supply. An input plug connected to and projecting from the body is electrically coupled to the signal amplifying and processing system. When the plug is inserted into an output jack for an electric guitar, the body is rigidly carried by the guitar, and the guitar is operatively connected to the electrical amplifying and signal processing system without use of a loose interconnection cable. The amplifier is provided with an output jack, into which headphones are plugged to receive amplified signals from the guitar. By eliminating the conventional interconnection cable, the amplifier of the present invention can be used by musicians with increased flexibility and greater freedom of movement.

  5. The effect of ligation on the load deflection characteristics of nickel titanium orthodontic wire.

    Science.gov (United States)

    Kasuya, Shugo; Nagasaka, Satoshi; Hanyuda, Ai; Ishimura, Sadao; Hirashita, Ayao

    2007-12-01

    This study examined the effect of ligation on the load-deflection characteristics of nickel-titanium (NiTi) orthodontic wire. A modified three-point bending system was used for bending the NiTi round wire, which was inserted and ligated in the slots of three brackets, one of which was bonded to each of the three bender rods. Three different ligation methods, stainless steel ligature (SSL), slot lid (SL), and elastomeric ligature (EL), were employed, as well as a control with neither bracket nor ligation (NBL). The tests were repeated five times under each condition. Comparisons were made of load-deflection curve, load at maximum deflection of 2,000 microm, and load at a deflection of 1,500 microm during unloading. Analysis of Variance (ANOVA) and Dunnett's test were conducted to determine method difference (alpha = 0.05). The interaction between deflection and ligation was tested, using repeated-measures ANOVA (alpha = 0.05). The load values of the ligation groups were two to three times greater than the NBL group at a deflection of 1,500 microm during unloading: 4.37 N for EL, 3.90 N for SSL, 3.02 N for SL, and 1.49 N for NBL (P wire may make NiTi wire exhibit a significantly heavier load than that traditionally expected. NiTi wire exhibited the majority of its true superelasticity with SL, whereas EL may act as a restraint on its superelasticity.

  6. Simultaneous detection of genetically modified organisms by multiplex ligation-dependent genome amplification and capillary gel electrophoresis with laser-induced fluorescence.

    Science.gov (United States)

    García-Cañas, Virginia; Mondello, Monica; Cifuentes, Alejandro

    2010-07-01

    In this work, an innovative method useful to simultaneously analyze multiple genetically modified organisms is described. The developed method consists in the combination of multiplex ligation-dependent genome dependent amplification (MLGA) with CGE and LIF detection using bare-fused silica capillaries. The MLGA process is based on oligonucleotide constructs, formed by a universal sequence (vector) and long specific oligonucleotides (selectors) that facilitate the circularization of specific DNA target regions. Subsequently, the circularized target sequences are simultaneously amplified with the same couple of primers and analyzed by CGE-LIF using a bare-fused silica capillary and a run electrolyte containing 2-hydroxyethyl cellulose acting as both sieving matrix and dynamic capillary coating. CGE-LIF is shown to be very useful and informative for optimizing MLGA parameters such as annealing temperature, number of ligation cycles, and selector probes concentration. We demonstrate the specificity of the method in detecting the presence of transgenic DNA in certified reference and raw commercial samples. The method developed is sensitive and allows the simultaneous detection in a single run of percentages of transgenic maize as low as 1% of GA21, 1% of MON863, and 1% of MON810 in maize samples with signal-to-noise ratios for the corresponding DNA peaks of 15, 12, and 26, respectively. These results demonstrate, to our knowledge for the first time, the great possibilities of MLGA techniques for genetically modified organisms analysis.

  7. Cross-catalytic peptide nucleic acid (PNA) replication based on templated ligation

    DEFF Research Database (Denmark)

    Singhal, Abhishek; Nielsen, Peter E

    2014-01-01

    We report the first PNA self-replicating system based on template directed cross-catalytic ligation, a process analogous to biological replication. Using two template PNAs and four pentameric precursor PNAs, all four possible carbodiimide assisted amide ligation products were detected...... precursors. Cross-catalytic product formation followed product inhibited kinetics, but approximately two replication rounds were observed. Analogous but less efficient replication was found for a similar tetrameric system. These results demonstrate that simpler nucleobase replication systems than natural...

  8. Subcutaneous endoscopically assisted ligation using miniport for ...

    African Journals Online (AJOL)

    Background This report describes the first miniport method using subcutaneous endoscopically assisted ligation (SEAL) for the treatment of girls with inguinal hernia. To validate its safety and efficacy, the authors evaluated their early experiences. Methods Between April 2014 and December 2014, 19 SEALs using miniport ...

  9. Performance analysis of selective cooperation in amplify-and-forward relay networks over identical Nakagami-m channels

    KAUST Repository

    Hussain, Syed Imtiaz; Alouini, Mohamed-Slim; Hasna, Mazen Omar

    2011-01-01

    In cooperative communications, multiple relays between a source and a destination can increase the diversity gain. Because all the nodes must use orthogonal channels, multiple-relay cooperation becomes spectrally inefficient. Therefore, a bestrelay selection scheme was recently proposed. In this paper, we analyzed the performance of this scheme for a system with the relays operating in amplify-and-forward mode over identical Nakagami-m channels using an exact source-relay-destination signal-to-noise ratio (SNR).We derived accurate closed-form expressions for various system parameters including the probability density function of end-to-end SNR, the average output SNR, the bit error probability, and the channel capacity. The analytical results were verified through Monte Carlo simulations. Copyright © 2011 John Wiley & Sons, Ltd.

  10. Performance analysis of selective cooperation in amplify-and-forward relay networks over identical Nakagami-m channels

    KAUST Repository

    Hussain, Syed Imtiaz

    2011-05-02

    In cooperative communications, multiple relays between a source and a destination can increase the diversity gain. Because all the nodes must use orthogonal channels, multiple-relay cooperation becomes spectrally inefficient. Therefore, a bestrelay selection scheme was recently proposed. In this paper, we analyzed the performance of this scheme for a system with the relays operating in amplify-and-forward mode over identical Nakagami-m channels using an exact source-relay-destination signal-to-noise ratio (SNR).We derived accurate closed-form expressions for various system parameters including the probability density function of end-to-end SNR, the average output SNR, the bit error probability, and the channel capacity. The analytical results were verified through Monte Carlo simulations. Copyright © 2011 John Wiley & Sons, Ltd.

  11. Operation Amplifier

    NARCIS (Netherlands)

    Tetsuya, Saito; Nauta, Bram

    2011-01-01

    PROBLEM TO BE SOLVED: To provide an operation amplifier which improves power source voltage removal ratios while assuring phase compensation characteristics, and therefore can be realized with a small-scale circuit and low power consumption. SOLUTION: The operation amplifier comprises: a

  12. Operation Amplifier

    NARCIS (Netherlands)

    Tetsuya, S.; Nauta, Bram

    2007-01-01

    PROBLEM TO BE SOLVED: To provide an operation amplifier which improves power source voltage removal ratios while assuring phase compensation characteristics, and therefore can be realized with a small-scale circuit and low power consumption. ; SOLUTION: The operation amplifier comprises: a

  13. Recovery of vocal fold immobility following isolated patent ductus arteriosus ligation.

    Science.gov (United States)

    Nichols, Brent G; Jabbour, Jad; Hehir, David A; Ghanayem, Nancy S; Beste, David; Martin, Timothy; Woods, Ronald; Robey, Thomas

    2014-08-01

    Identify laryngoscopic and functional outcomes of infants with vocal fold immobility (VFI) following patent ductus arteriosus (PDA) ligation and identify predictors of recovery. Retrospective review of patients with VFI following PDA ligation from 2001 to 2012 at a single institution. Inclusion criteria were: (1) PDA ligation as only cardiac surgical procedure; (2) left VFI documented by laryngoscopy; (3) minimum follow up 120 days, with at least 2 laryngoscopies performed. Resolution of VFI was determined at follow-up laryngoscopy. Univariate logistic regression models were used to identify variables associated with VFI recovery. 66 subjects were included with median follow up of 3.0 (± 2.1) years. The mean gestational age was 24.5 ± 1.4 weeks, mean birth weight 673 ± 167 g, and mean age at procedure was 18.6 ± 14.3 days. Patients presented with respiratory symptoms (39%), dysphonia (78%) and dysphagia (55%). Resolution of VFI was observed in 2/66 (3%) patients. Recovery was documented at 20 days and 11 months respectively. Respiratory symptoms, dysphagia, and dysphonia persisted at last follow up in 11%, 47%, and 20% of patients. VFI associated with ligation of the ductus arteriosus has a low rate of recovery. Clinical symptoms frequently persist, and as such regular follow-up by otolaryngologists to mitigate morbidity is indicated. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. Can interposition of a silicone implant after sapheno-femoral ligation prevent recurrent varicose veins?

    NARCIS (Netherlands)

    de Maeseneer, M. G.; Giuliani, D. R.; van Schil, P. E.; de Hert, S. G.

    2002-01-01

    OBJECTIVES: To investigate whether a silicone implant at the sapheno-femoral ligation site could prevent recurrent varicosities. MATERIALS AND METHODS: Two non-randomised groups of patients were studied prospectively. In group A 173 patients and 212 limbs had sapheno-femoral ligation, while 172

  15. Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations

    Science.gov (United States)

    MONTEIRO, Maria Regina Guerra; da SILVA, Licinio Esmeraldo; ELIAS, Carlos Nelson; VILELLA, Oswaldo de Vasconcellos

    2014-01-01

    Objective To compare the influence of archwire material (NiTi, beta-Ti and stainless steel) and brackets design (self-ligating and conventional) on the frictional force resistance. Material and Methods Two types of brackets (self-ligating brackets - Smartclip, 3M/Unitek - and conventional brackets - Gemini, 3M/Unitek) with three (0, 5, and 10 degrees) slot angulation attached with elastomeric ligatures (TP Orthodontics) were tested. All brackets were tested with archwire 0.019"x0.025" nickel-titanium, beta-titanium, and stainless steel (Unitek/3M). The mechanical testing was performed with a universal testing machine eMIC DL 10000 (eMIC Co, Brazil). The wires were pulled from the bracket slots at a cross-head speed of 3 mm/min until 2 mm displacement. Results Self-ligating brackets produced significantly lower friction values compared with those of conventional brackets. Frictional force resistance values were directly proportional to the increase in the bracket/ wire angulation. With regard to conventional brackets, stainless steel wires had the lowest friction force values, followed by nickel-titanium and beta-titanium ones. With regard to self-ligating brackets, the nickel-titanium wires had the lowest friction values, significantly lower than those of other materials. Conclusion even at different angulations, the self-ligating brackets showed significantly lower friction force values than the conventional brackets. Combined with nickel-titanium wires, the self-ligating brackets exhibit much lower friction, possibly due to the contact between nickel-titanium clips and wires of the same material. PMID:25025564

  16. Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations

    Directory of Open Access Journals (Sweden)

    Maria Regina Guerra MONTEIRO

    2014-06-01

    Full Text Available Objective: To compare the influence of archwire material (NiTi, beta-Ti and stainless steel and brackets design (self-ligating and conventional on the frictional force resistance. Material and Methods: Two types of brackets (self-ligating brackets - Smartclip, 3M/Unitek - and conventional brackets - Gemini, 3M/Unitek with three (0, 5, and 10 degrees slot angulation attached with elastomeric ligatures (TP Orthodontics were tested. All brackets were tested with archwire 0.019"x0.025" nickel-titanium, beta-titanium, and stainless steel (Unitek/3M. The mechanical testing was performed with a universal testing machine eMIC DL 10000 (eMIC Co, Brazil. The wires were pulled from the bracket slots at a cross-head speed of 3 mm/min until 2 mm displacement. Results: Self-ligating brackets produced significantly lower friction values compared with those of conventional brackets. Frictional force resistance values were directly proportional to the increase in the bracket/ wire angulation. With regard to conventional brackets, stainless steel wires had the lowest friction force values, followed by nickel-titanium and beta-titanium ones. With regard to self-ligating brackets, the nickel-titanium wires had the lowest friction values, significantly lower than those of other materials. Conclusion: even at different angulations, the self-ligating brackets showed significantly lower friction force values than the conventional brackets. Combined with nickel-titanium wires, the self-ligating brackets exhibit much lower friction, possibly due to the contact between nickel-titanium clips and wires of the same material.

  17. Comparison of Frictional Forces Generated by a New Ceramic Bracket with the Conventional Brackets using Unconventional and Conventional Ligation System and the Self-ligating Brackets: An In Vitro Study.

    Science.gov (United States)

    Pasha, Azam; Vishwakarma, Swati; Narayan, Anjali; Vinay, K; Shetty, Smitha V; Roy, Partha Pratim

    2015-09-01

    Fixed orthodontic mechanotherapy is associated with friction between the bracket - wire - ligature interfaces during the sliding mechanics. A sound knowledge of the various factors affecting the magnitude of friction is of paramount importance. The present study was done to analyze and compare the frictional forces generated by a new ceramic (Clarity Advanced) bracket with the conventional, (metal and ceramic) brackets using unconventional and conventional ligation system, and the self-ligating (metal and ceramic) brackets in the dry condition. The various bracket wire ligation combinations were tested in dry condition. The brackets used were of 0.022″ × 0.028″ nominal slot dimension of MBT prescription: Stainless steel (SS) self-ligating bracket (SLB) of (SmartClip), SS Conventional bracket (CB) (Victory series), Ceramic SLB (Clarity SL), Conventional Ceramic bracket with metal slot (Clarity Bracket), Clarity Advanced Ceramic Brackets (Clarity(™) ADVANCED, 3M Unitek). These brackets were used with two types of elastomeric ligatures: Conventional Elastomeric Ligatures (CEL) (Clear medium mini modules) and Unconventional Elastomeric Ligatures (UEL) (Clear medium slide ligatures, Leone orthodontic products). The aligning and the retraction wires were used, i.e., 0.014″ nickel titanium (NiTi) wires and 0.019″ × 0.025″ SS wires, respectively. A universal strength testing machine was used to measure the friction produced between the different bracket, archwires, and ligation combination. This was done with the use of a custom-made jig being in position. Mean, standard deviation, and range were computed for the frictional values obtained. Results were subjected to statistical analysis through ANOVA. The frictional resistance observed in the new Clarity Advanced bracket with a conventional elastomeric ligature was almost similar with the Clarity metal slot bracket with a conventional elastomeric ligature. When using the UEL, the Clarity Advanced bracket

  18. Digestion-ligation-only Hi-C is an efficient and cost-effective method for chromosome conformation capture.

    Science.gov (United States)

    Lin, Da; Hong, Ping; Zhang, Siheng; Xu, Weize; Jamal, Muhammad; Yan, Keji; Lei, Yingying; Li, Liang; Ruan, Yijun; Fu, Zhen F; Li, Guoliang; Cao, Gang

    2018-05-01

    Chromosome conformation capture (3C) technologies can be used to investigate 3D genomic structures. However, high background noise, high costs, and a lack of straightforward noise evaluation in current methods impede the advancement of 3D genomic research. Here we developed a simple digestion-ligation-only Hi-C (DLO Hi-C) technology to explore the 3D landscape of the genome. This method requires only two rounds of digestion and ligation, without the need for biotin labeling and pulldown. Non-ligated DNA was efficiently removed in a cost-effective step by purifying specific linker-ligated DNA fragments. Notably, random ligation could be quickly evaluated in an early quality-control step before sequencing. Moreover, an in situ version of DLO Hi-C using a four-cutter restriction enzyme has been developed. We applied DLO Hi-C to delineate the genomic architecture of THP-1 and K562 cells and uncovered chromosomal translocations. This technology may facilitate investigation of genomic organization, gene regulation, and (meta)genome assembly.

  19. Air-powder polishing on self-ligating brackets after clinical use: effects on debris levels.

    Science.gov (United States)

    Aragón, Mônica L S Castro; Lima, Leandro Santiago; Normando, David

    2016-01-01

    Debris buildup on brackets and arch surfaces is one of the main factors that can influence the intensity of friction between bracket and orthodontic wire. This study sought to evaluate the effect of air-powder polishing cleaning on debris levels of self-ligating ceramic brackets at the end of orthodontic treatment, compared to the behavior of conventional brackets. Debris levels were evaluated in metal conventional orthodontic brackets (n = 42) and ceramic self-ligating brackets (n = 42) on canines and premolars, arranged in pairs. There were brackets with and without air-powder polishing. At the end of orthodontic treatment, a hemiarch served as control and the contralateral hemiarch underwent prophylaxis with air-powder polishing. Debris buildup in bracket slots was assessed through images, and Wilcoxon test was used to analyze the results. The median debris levels were statistically lower in the conventional metal brackets compared to self-ligating ones (p = 0.02), regarding brackets not submitted to air-powder polishing. Polishing significantly reduced debris buildup to zero in both systems, without differences between groups. Ceramic self-ligating brackets have a higher debris buildup in comparison to conventional metal brackets in vivo, but prophylaxis with sodium bicarbonate jet was effective in reducing debris levels in self-ligating and also in conventional brackets.

  20. OUTCOMES OF HILAR PEDICLE CONTROL USING SUTURE LIGATION DURING LAPAROSCOPIC SPLENECTOMY.

    Science.gov (United States)

    Makgoka, M

    2017-06-01

    Laparoscopic splenectomy is a well described gold standard procedure for various indications. One of the key steps during laparoscopic splenectomy is the hilar pedicle vessels control, which can be challenging in most cases. Most centres around the world recommend the use Ligaclib or endovascular staplers as Methods of choice for hilar pedicle control but the issue is the cost and efficiency of the laparoscopic haemostatic devices. A descriptive retrospective study of patients who had laparoscopic splenectomy from 2013 to present. Hilar splenic vessel control was done with suture ligation. We looked at outcomes of patients offered this technique, complications of this technique, and describing the technique of hilar control in laparoscopic splenectomy. Total of 27 patients had laparoscopic splenectomy with splenic hilar pedicle control with suture ligation. Mean operative time, mean blood volume loss, length of hospital stay, postoperative complications conversion to laparotomy. Laparoscopic hilar pedicle control with suture ligation is safe and effective for the patient in our hospital setting.

  1. Distributed feedback laser amplifiers combining the functions of amplifiers and channel filters

    DEFF Research Database (Denmark)

    Wang, Z.; Durhuus, T.; Mikkelsen, Benny

    1994-01-01

    A dynamic model for distributed feedback amplifiers, including the mode coupled equations and the carrier rate equation, is established. The presented mode coupled equations have taken into account the interaction between fast changing optical signal and the waveguide with corrugations. By showin...... the possibility of amplifying 100 ps pulses without pulse broadening, we anticipate that a distributed feedback amplifier can be used as a combined amplifier and channel filter in high bit rate transmission systems....

  2. Covalent attachment of proteins to solid supports and surfaces via Sortase-mediated ligation.

    Directory of Open Access Journals (Sweden)

    Lilyan Chan

    Full Text Available BACKGROUND: There is growing interest in the attachment of proteins to solid supports for the development of supported catalysts, affinity matrices, and micro devices as well as for the development of planar and bead based protein arrays for multiplexed assays of protein concentration, interactions, and activity. A critical requirement for these applications is the generation of a stable linkage between the solid support and the immobilized, but still functional, protein. METHODOLOGY: Solid supports including crosslinked polymer beads, beaded agarose, and planar glass surfaces, were modified to present an oligoglycine motif to solution. A range of proteins were ligated to the various surfaces using the Sortase A enzyme of S. aureus. Reactions were carried out in aqueous buffer conditions at room temperature for times between one and twelve hours. CONCLUSIONS: The Sortase A transpeptidase of S. aureus provides a general, robust, and gentle approach to the selective covalent immobilization of proteins on three very different solid supports. The proteins remain functional and accessible to solution. Sortase mediated ligation is therefore a straightforward methodology for the preparation of solid supported enzymes and bead based assays, as well as the modification of planar surfaces for microanalytical devices and protein arrays.

  3. Subcutaneous endoscopically assisted ligation using miniport for ...

    African Journals Online (AJOL)

    miniport for the treatment of girls with inguinal hernia. Akinari Hinoki*, Ikeda ... method using subcutaneous endoscopically assisted ligation (SEAL) for the ... the open technique and an additional 2 mm miniport). A ... (unilateral, n = 9) or 42 ± 8 min (bilateral, n = 5). The mean .... Methods of laparoscopic repair have recently ...

  4. Acute kidney injury secondary to iatrogenic bilateral ureteric ligation ...

    African Journals Online (AJOL)

    Acute kidney injury secondary to iatrogenic bilateral ureteric ligation following emergency abdominal hysterectomy. Oluseyi A. Adejumo, Olurotimi S. Ogundiniyi, Ayodeji A. Akinbodewa, Lawrence A. Adesunloro, Oladimeji J. Olafisoye ...

  5. A Method To ModifyCorrect The Performance Of Amplifiers

    Directory of Open Access Journals (Sweden)

    Rohith Krishnan R

    2015-01-01

    Full Text Available Abstract The actual response of the amplifier may vary with the replacement of some aged or damaged components and this method is to compensate that problem. Here we use op-amp Fixator as the design tool. The tool helps us to isolate the selected circuit component from rest of the circuit adjust its operating point to correct the performance deviations and to modify the circuit without changing other parts of the circuit. A method to modifycorrect the performance of amplifiers by properly redesign the circuit is presented in this paper.

  6. Elevated mitochondrial gene expression during rat liver regeneration after portal vein ligation.

    Science.gov (United States)

    Shimizu, Y; Suzuki, H; Nimura, Y; Onoue, S; Nagino, M; Tanaka, M; Ozawa, T

    1995-10-01

    We explored the molecular basis of mitochondrial energy production during rat liver regeneration after portal vein ligation. Ligation of the left branch of the portal vein induces an increase in the weight of the nonligated lobe, counterbalancing the reduced weight of the ligated lobe. Using this model, we investigated changes in mitochondrial DNA-binding proteins, mitochondrial DNA, and mitochondrial messenger RNA (mRNA) in rat hepatocytes of the nonligated lobes. The amount of mitochondrial DNA-binding protein increased maximally (200% to 300% of the preoperative level) at 12 hours after the operation, before an increase (390%) in mitochondrial DNA content at 24 hours, and parallel to an increase (240%) in mitochondrial mRNA levels at 12 hours. These results suggest that the energy supply for liver regeneration is achieved through enhancement of mitochondrial DNA replication as well as transcription, in which the mitochondrial DNA-binding proteins probably play regulatory roles. We also found that in the nonligated lobes, mRNA levels of hepatocyte growth factor increased to a detectable level only 12 hours after the operation. These molecular biochemical data help explain why preoperative portal vein embolization, which is a modification of portal vein branch ligation, is an effective method to prevent posthepatectomy liver failure.

  7. Access to bifunctionalized biomolecular platforms using oxime ligation

    Czech Academy of Sciences Publication Activity Database

    Křenek, Karel; Gažák, Radek; Daskhan, G. Ch.; Garcia, J.; Fiore, M.; Dumy, P.; Šulc, Miroslav; Křen, Vladimír; Renaudet, O.

    2014-01-01

    Roč. 393, JUL 2014 (2014), s. 9-14 ISSN 0008-6215 R&D Projects: GA MŠk(CZ) LD13042 Institutional support: RVO:61388971 Keywords : Chemoselective ligation * Glycocluster * Cyclopeptide Subject RIV: CC - Organic Chemistry Impact factor: 1.929, year: 2014

  8. Evaluation of common vaginal tunic ligation during field castration in draught colts.

    Science.gov (United States)

    Carmalt, J L; Shoemaker, R W; Wilson, D G

    2008-09-01

    The objective of this study was to determine if ligation of the common vaginal tunic could prevent or reduce the incidence of omental herniation and eventration in draught colts undergoing routine field castration. It was found that common vaginal tunic ligation, while not completely preventing omental herniation and evisceration, significantly reduced the incidence of these complications and should be considered in those males deemed at increased risk of significant post castration complications.

  9. Antares laser power amplifier

    International Nuclear Information System (INIS)

    Stine, R.D.; Ross, G.F.; Silvernail, C.

    1979-01-01

    The overall design of the Antares laser power amplifier is discussed. The power amplifier is the last stage of amplification in the 100-kJ Antares laser. In the power amplifier a single, cylindrical, grid-controlle, cold-cathode electron gun is surrounded by 12 large-aperture CO 2 electron-beam sustained laser discharge sectors. Each power amplifier will deliver 18 kJ and the six modules used in Antares will produce the required 100 kJ for delivery to the target. A large-scale interaction between optical, mechanical, and electrical disciplines is required to meet the design objectives. Significant component advances required by the power amplifier design are discussed

  10. Amplification factor variable amplifier

    NARCIS (Netherlands)

    Akitsugu, Oshita; Nauta, Bram

    2007-01-01

    PROBLEM TO BE SOLVED: To provide an amplification factor variable amplifier capable of achieving temperature compensation of an amplification factor over a wide variable amplification factor range. ; SOLUTION: A Gilbert type amplification factor variable amplifier 11 amplifies an input signal and

  11. Ligation bias in illumina next-generation DNA libraries: implications for sequencing ancient genomes.

    Directory of Open Access Journals (Sweden)

    Andaine Seguin-Orlando

    Full Text Available Ancient DNA extracts consist of a mixture of endogenous molecules and contaminant DNA templates, often originating from environmental microbes. These two populations of templates exhibit different chemical characteristics, with the former showing depurination and cytosine deamination by-products, resulting from post-mortem DNA damage. Such chemical modifications can interfere with the molecular tools used for building second-generation DNA libraries, and limit our ability to fully characterize the true complexity of ancient DNA extracts. In this study, we first use fresh DNA extracts to demonstrate that library preparation based on adapter ligation at AT-overhangs are biased against DNA templates starting with thymine residues, contrarily to blunt-end adapter ligation. We observe the same bias on fresh DNA extracts sheared on Bioruptor, Covaris and nebulizers. This contradicts previous reports suggesting that this bias could originate from the methods used for shearing DNA. This also suggests that AT-overhang adapter ligation efficiency is affected in a sequence-dependent manner and results in an uneven representation of different genomic contexts. We then show how this bias could affect the base composition of ancient DNA libraries prepared following AT-overhang ligation, mainly by limiting the ability to ligate DNA templates starting with thymines and therefore deaminated cytosines. This results in particular nucleotide misincorporation damage patterns, deviating from the signature generally expected for authenticating ancient sequence data. Consequently, we show that models adequate for estimating post-mortem DNA damage levels must be robust to the molecular tools used for building ancient DNA libraries.

  12. Friction between various self-ligating brackets and archwire couples during sliding mechanics.

    Science.gov (United States)

    Stefanos, Sennay; Secchi, Antonino G; Coby, Guy; Tanna, Nipul; Mante, Francis K

    2010-10-01

    The aim of this study was to evaluate the frictional resistance between active and passive self-ligating brackets and 0.019 × 0.025-in stainless steel archwire during sliding mechanics by using an orthodontic sliding simulation device. Maxillary right first premolar active self-ligating brackets In-Ovation R, In-Ovation C (both, GAC International, Bohemia, NY), and SPEED (Strite Industries, Cambridge, Ontario, Canada), and passive self-ligating brackets SmartClip (3M Unitek, Monrovia, Calif), Synergy R (Rocky Mountain Orthodontics, Denver, Colo), and Damon 3mx (Ormco, Orange, Calif) with 0.022-in slots were used. Frictional force was measured by using an orthodontic sliding simulation device attached to a universal testing machine. Each bracket-archwire combination was tested 30 times at 0° angulation relative to the sliding direction. Statistical comparisons were performed with 1-way analysis of variance (ANOVA) followed by Dunn multiple comparisons. The level of statistical significance was set at P <0.05. The Damon 3mx brackets had significantly the lowest mean static frictional force (8.6 g). The highest mean static frictional force was shown by the SPEED brackets (83.1 g). The other brackets were ranked as follows, from highest to lowest, In-Ovation R, In-Ovation C, SmartClip, and Synergy R. The mean static frictional forces were all statistically different. The ranking of the kinetic frictional forces of bracket-archwire combinations was the same as that for static frictional forces. All bracket-archwire combinations showed significantly different kinetic frictional forces except SmartClip and In-Ovation C, which were not significantly different from each other. Passive self-ligating brackets have lower static and kinetic frictional resistance than do active self-ligating brackets with 0.019 × 0.025-in stainless steel wire. Copyright © 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  13. Dead time effects from linear amplifiers and discriminators in single detector systems

    International Nuclear Information System (INIS)

    Funck, E.

    1986-01-01

    The dead-time losses originating from a linear amplifier combined with a discriminator for pulse-height selection are investigated. Measurements are carried out to determine the type of dead time represented by the amplifier-discriminator combination. The corrections involved by feeding the discriminator output pulses into an electronic module producing a blocking time are discussed and practical hints are given to reduce them. (orig.)

  14. Amplification factor variable amplifier

    NARCIS (Netherlands)

    Akitsugu, Oshita; Nauta, Bram

    2010-01-01

    PROBLEM TO BE SOLVED: To provide an amplification factor variable amplifier capable of achieving temperature compensation of an amplification factor over a wide variable amplification factor range. ;SOLUTION: A Gilbert type amplification factor variable amplifier 11 amplifies an input signal and can

  15. Arterial Ligation for Infected Femoral Psuedo-Aneurysm in Drug Injecting Abusers

    Directory of Open Access Journals (Sweden)

    Mohammadzade Mohammad Ali

    2009-10-01

    Full Text Available Pseudo-aneurysm of the femoral artery is the most common arterial complication in drug injecting abusers. Scholars in vascular surgery have published debating statements regarding techniques of successful surgical management during last two decades. We present the results of simple arterial ligation in a series of 32 patients presenting with infected femoral pseudo-aneurysm. Most of the patients were males (89%. Young persons in the age group of 15-44 years were mostly affected. Site of lesion included common femoral artery in 65% , superficial femoral artery 28% and at bifurcation 6.2%. celulitis in 14 (53%, abscess & "ncelulitis in 6 (19%, necrosing fasciitis in 2 (6.2% and vascular abscess in 7 (22% cases were the forms of associated local infection. There was no hemorrhage, vascular thrombosis, amputation, or mortality. Claudicating were the only complications identified in 2 patients with Tripe ligation. Ligation is the optimal management for infected pseudo-aneurysms because it is easy, cost-effective, and safe. Early reconstruction is not recommended, since there is an extended infection in the location of the pseudo-aneurysm.

  16. Profiling cellular protein complexes by proximity ligation with dual tag microarray readout.

    Science.gov (United States)

    Hammond, Maria; Nong, Rachel Yuan; Ericsson, Olle; Pardali, Katerina; Landegren, Ulf

    2012-01-01

    Patterns of protein interactions provide important insights in basic biology, and their analysis plays an increasing role in drug development and diagnostics of disease. We have established a scalable technique to compare two biological samples for the levels of all pairwise interactions among a set of targeted protein molecules. The technique is a combination of the proximity ligation assay with readout via dual tag microarrays. In the proximity ligation assay protein identities are encoded as DNA sequences by attaching DNA oligonucleotides to antibodies directed against the proteins of interest. Upon binding by pairs of antibodies to proteins present in the same molecular complexes, ligation reactions give rise to reporter DNA molecules that contain the combined sequence information from the two DNA strands. The ligation reactions also serve to incorporate a sample barcode in the reporter molecules to allow for direct comparison between pairs of samples. The samples are evaluated using a dual tag microarray where information is decoded, revealing which pairs of tags that have become joined. As a proof-of-concept we demonstrate that this approach can be used to detect a set of five proteins and their pairwise interactions both in cellular lysates and in fixed tissue culture cells. This paper provides a general strategy to analyze the extent of any pairwise interactions in large sets of molecules by decoding reporter DNA strands that identify the interacting molecules.

  17. Increased secretion of insulin and proliferation of islet β-cells in rats with mesenteric lymph duct ligation

    International Nuclear Information System (INIS)

    Nagino, Ko; Yokozawa, Junji; Sasaki, Yu; Matsuda, Akiko; Takeda, Hiroaki; Kawata, Sumio

    2012-01-01

    Highlights: ► Insulin secretion was increased during the OGTT or IVGTT in mesenteric lymph duct-ligated rats. ► Proliferation of islet β-cells was upregulated in lymph duct-ligated rats. ► Mesenteric lymph duct flow has a role in glucose metabolism. -- Abstract: Background and aims: It has been suggested that intestinal lymph flow plays an important role in insulin secretion and glucose metabolism after meals. In this study, we investigated the influence of ligation of the mesenteric lymph duct on glucose metabolism and islet β-cells in rats. Methods: Male Sprague–Dawley rats (10 weeks old) were divided into two groups: one underwent ligation of the mesenteric lymph duct above the cistern (ligation group), and the other underwent a sham operation (sham group). After 1 and 2 weeks, fasting plasma concentrations of glucose, insulin, triglyceride, glucose-dependent insulinotropic polypeptide (GIP), and the active form of glucagon-like peptide-1 (GLP-1) were measured. At 2 weeks after the operation, the oral glucose tolerance test (OGTT) and intravenous glucose tolerance test (IVGTT) were performed. After the rats had been sacrificed, the insulin content of the pancreas was measured and the proliferation of β-cells was assessed immunohistochemically using antibodies against insulin and Ki-67. Results: During the OGTT, the ligation group showed a significant decrease in the plasma glucose concentration at 120 min (p < 0.05) and a significant increase in the plasma insulin concentration by more than 2-fold at 15 min (p < 0.01). On the other hand, the plasma GIP concentration was significantly decreased at 60 min (p < 0.01) in the ligated group, while the active form of GLP-1 showed a significantly higher level at 90 min (1.7-fold; p < 0.05) and 120 min (2.5-fold; p < 0.01). During the IVGTT, the plasma insulin concentration in the ligation group was significantly higher at 2 min (more than 1.4-fold; p < 0.05). Immunohistochemistry showed that the ratios of

  18. Sphenopalatine artery ligation: technical note.

    Science.gov (United States)

    Pothier, David D; Mackeith, Samuel; Youngs, Robin

    2005-10-01

    Epistaxis is a common problem. Most patients presenting to hospital will stop bleeding with simple first-aid measures or with nasal packing. Those who do not stop will usually require surgical management. For persistent posterior epistaxis, the sphenopalatine artery may be ligated as the artery leaves the sphenopalatine foramen to enter the nasal mucosa of the lateral wall of the nose. This may be performed endoscopically. We describe the anatomy of the area and the surgical technique. We also present a brief review of the literature on this technique.

  19. A "typodont" study of rate of orthodontic space closure: self-ligating systems vs. conventional systems.

    Science.gov (United States)

    Saporito, I; Butti, A C; Salvato, A; Biagi, R

    2011-01-01

    The aim of this study was to compare the effectiveness of space closure of two bracket systems, self-ligating and conventional ones, considering two systems with the same design and prescription. The experimental model of this study aims to identify in general if one type of system is more suitable for planning the extractive therapy, without considering the clinical aspect necessary for an adequate orthodontic approach. A resin maxilla without the first premolars was used to test the self-ligating and conventional brackets system. Space closure was achieved on 0.016x0.022" in stainless steel wires with nickel-titanium coil springs 150 grams in strength and 10 mm in length. Two experiment settings have been prepared. The first setting was made bonding conventional bracket on the right side and self-ligating on the left; the last one was made bonding self-ligating bracket on the right side and conventional on the left. All measurements (runs) have been repeated seven times for both settings. During the closing phase of extraction spaces both systems are equable since there are no significant statistical differences (P=0.70). Our typodont model showed no significant difference in the efficiency of space closure between the self-ligating bracket and conventional bracket tied with stainless steel ligatures.

  20. Coronary ligation reduces maximum sustained swimming speed in Chinook salmon, Oncorhynchus tshawytscha

    DEFF Research Database (Denmark)

    Farrell, A P; Steffensen, J F

    1987-01-01

    The maximum aerobic swimming speed of Chinook salmon (Oncorhynchus tshawytscha) was measured before and after ligation of the coronary artery. Coronary artery ligation prevented blood flow to the compact layer of the ventricular myocardium, which represents 30% of the ventricular mass, and produced...... a statistically significant 35.5% reduction in maximum swimming speed. We conclude that the coronary circulation is important for maximum aerobic swimming and implicit in this conclusion is that maximum cardiac performance is probably necessary for maximum aerobic swimming performance....

  1. Elastic band ligation of hemorrhoids using flexible gastroscope

    Directory of Open Access Journals (Sweden)

    Hadi Abd Zaid Al-Khattabi

    2017-03-01

    Conclusion High success rate, cost effectiveness and the simplicity of rubber band ligation as an outpatient procedure promote its use as the frst line of treatment for frst, second and early third degree hemorrhoids.

  2. CMOS Current-mode Operational Amplifier

    DEFF Research Database (Denmark)

    Kaulberg, Thomas

    1992-01-01

    current-mode feedback amplifier or a constant bandwidth in a transimpedance feedback amplifier. The amplifier is found to have a gain bandwidth product of 8 MHz, an offset current of 0.8 ¿A (signal-range ±700¿A) and a (theoretically) unlimited slew-rate. The amplifier is realized in a standard CMOS 2......A fully differential-input differential-output current-mode operational amplifier (COA) is described. The amplifier utilizes three second generation current-conveyors (CCII) as the basic building blocks. It can be configured to provide either a constant gain-bandwidth product in a fully balanced...

  3. Demonstration of metabolic and cellular effects of portal vein ligation using multi-modal PET/MRI measurements in healthy rat liver.

    Directory of Open Access Journals (Sweden)

    András Fülöp

    Full Text Available OBJECTIVES: In the early recognition of portal vein ligation (PVL induced tumor progression, positron emission tomography and magnetic resonance imaging (PET/MRI could improve diagnostic accuracy of conventionally used methods. It is unknown how PVL affects metabolic patterns of tumor free hepatic tissues. The aim of this preliminary study is to evaluate the effect of PVL on glucose metabolism, using PET/MRI imaging in healthy rat liver. MATERIALS AND METHODS: Male Wistar rats (n=30 underwent PVL. 2-deoxy-2-(18Ffluoro-D-glucose (FDG PET/MRI imaging (nanoScan PET/MRI and morphological/histological examination were performed before (Day 0 and 1, 2, 3, and 7 days after PVL. Dynamic PET data were collected and the standardized uptake values (SUV for ligated and non-ligated liver lobes were calculated in relation to cardiac left ventricle (SUVVOI/SUVCLV and mean liver SUV (SUVVOI/SUVLiver. RESULTS: PVL induced atrophy of ligated lobes, while non-ligated liver tissue showed compensatory hypertrophy. Dynamic PET scan revealed altered FDG kinetics in both ligated and non-ligated liver lobes. SUVVOI/SUVCLV significantly increased in both groups of lobes, with a maximal value at the 2nd postoperative day and returned near to the baseline 7 days after the ligation. After PVL, ligated liver lobes showed significantly higher tracer uptake compared to the non-ligated lobes (significantly higher SUVVOI/SUVLiver values were observed at postoperative day 1, 2 and 3. The homogenous tracer biodistribution observed before PVL reappeared by 7th postoperative day. CONCLUSION: The observed alterations in FDG uptake dynamics should be taken into account during the assessment of PET data until the PVL induced atrophic and regenerative processes are completed.

  4. Bis-ligated Ti and Zr complexes of chelating N-heterocyclic carbenes

    KAUST Repository

    El-Batta, Amer

    2011-07-01

    In this communication we report the synthesis of novel titanium and zirconium complexes ligated by bidentate "salicylaldimine-like" N-heterocyclic carbenes (NHC). Double addition of the NHC chelate to either TiCl4(thf)2 or ZrCl4 forms bis-ligated organometallic fragments with a distorted octahedral geometry. These complexes are rare examples of group IV transition-metal NHC adducts. Preliminary catalytic tests demonstrate that in the presence of methylaluminoxane (MAO) these complexes are useful initiators for the polymerization of ethylene and the copolymerization of ethylene with norbornene and 1-octene. © 2011 Elsevier B.V. All rights reserved.

  5. Extrahepatic portal venous obstruction: The effects of early ligation of splenic artery during splenectomy.

    Science.gov (United States)

    Gazula, Suhasini; Pawar, D K; Seth, T; Bal, C S; Bhatnagar, V

    2009-10-01

    To objectively demonstrate the gain in blood volume and blood components following early ligation of splenic artery during splenectomy and splenorenal shunts in children with extra hepatic portal venous obstruction (EHPVO). Twenty-eight children (20 males and 8 females, mean age: 9.9 (+/-3.2) years) with EHPVO and hypersplenism were recruited. We followed a protocol of systematically locating and ligating the splenic artery first, followed by a 30-minute waiting period to allow the massive spleen to decongest via the splenic vein and venous collaterals and then completing the splenectomy by standard procedure. No intravenous fluid was administered during this 30-minute period. Blood samples were drawn just prior to splenic artery ligation and soon after splenectomy for the estimation of hematological and biochemical parameters. We noticed a highly significant increase in the hemoglobin, hematocrit, leukocyte, platelet, and RBC counts by early ligation of the splenic artery (p platelet count was equivalent to a platelet transfusion of atleast 4 units of platelet concentrates in an adult. There is a positive correlation between the splenic weight and the platelet gain (p= 0.0568) and the splenic volume on preoperative imaging and the platelet gain (p= 0.0251). Early ligation of the splenic artery during splenectomy results in passive splenic decongestion and thereby a significant gain in blood components. This protocol appears to be a feasible blood conservation method to avoid blood transfusions in this group of hypersplenic EHPVO patients.

  6. Venous Ligation: A Novel Strategy for Glans Enhancement in Penile Prosthesis Implantation

    Directory of Open Access Journals (Sweden)

    Geng-Long Hsu

    2014-01-01

    Full Text Available Although penile implantation remains a final solution for patients with refractory impotence, undesirable postoperative effects, including penile size reduction and cold sensation of the glans penis, remain problematic. We report results of a surgical method designed to avoid these problems. From 2003 to 2013, 35 consecutive patients received a malleable penile implant. Of these, 15 men (the enhancing group were also treated with venous ligation of the retrocoronal venous plexus, deep dorsal vein, and cavernosal veins. The remaining 20 men formed the control group, treated with only a penile implant. Follow-up ranged from 1.1 to 10.0 years, with an average of 6.7 ± 1.5 years. Although preoperative glanular dimension did not differ significantly between the two groups, significant respective difference at one day and one year postoperatively was found in the glanular circumference (128.8 ± 6.8 mm versus 115.3 ± 7.2 mm and 130.6 ± 7.2 mm versus 100.5 ± 7.3 mm; both P<0.05, radius (38.8 ± 2.7 mm versus 37.1 ± 2.8 mm and 41.5 ± 2.6 mm versus 33.8 ± 2.9 mm; latter P<0.01, and satisfaction rate (91.7% versus 53.3%, P<0.01 as well. Based on our results, selective venous ligation appears to enhance the glans penis dimension in implant patients.

  7. Urokinase-type plasminogen activator receptor (uPAR) ligation induces a raft-localized integrin signaling switch that mediates the hypermotile phenotype of fibrotic fibroblasts.

    Science.gov (United States)

    Grove, Lisa M; Southern, Brian D; Jin, Tong H; White, Kimberly E; Paruchuri, Sailaja; Harel, Efrat; Wei, Ying; Rahaman, Shaik O; Gladson, Candece L; Ding, Qiang; Craik, Charles S; Chapman, Harold A; Olman, Mitchell A

    2014-05-02

    The urokinase-type plasminogen activator receptor (uPAR) is a glycosylphosphatidylinositol-linked membrane protein with no cytosolic domain that localizes to lipid raft microdomains. Our laboratory and others have documented that lung fibroblasts from patients with idiopathic pulmonary fibrosis (IPF) exhibit a hypermotile phenotype. This study was undertaken to elucidate the molecular mechanism whereby uPAR ligation with its cognate ligand, urokinase, induces a motile phenotype in human lung fibroblasts. We found that uPAR ligation with the urokinase receptor binding domain (amino-terminal fragment) leads to enhanced migration of fibroblasts on fibronectin in a protease-independent, lipid raft-dependent manner. Ligation of uPAR with the amino-terminal fragment recruited α5β1 integrin and the acylated form of the Src family kinase, Fyn, to lipid rafts. The biological consequences of this translocation were an increase in fibroblast motility and a switch of the integrin-initiated signal pathway for migration away from the lipid raft-independent focal adhesion kinase pathway and toward a lipid raft-dependent caveolin-Fyn-Shc pathway. Furthermore, an integrin homologous peptide as well as an antibody that competes with β1 for uPAR binding have the ability to block this effect. In addition, its relative insensitivity to cholesterol depletion suggests that the interactions of α5β1 integrin and uPAR drive the translocation of α5β1 integrin-acylated Fyn signaling complexes into lipid rafts upon uPAR ligation through protein-protein interactions. This signal switch is a novel pathway leading to the hypermotile phenotype of IPF patient-derived fibroblasts, seen with uPAR ligation. This uPAR dependent, fibrotic matrix-selective, and profibrotic fibroblast phenotype may be amenable to targeted therapeutics designed to ameliorate IPF.

  8. Genotyping by sequencing (GBS, an ultimate marker-assisted selection (MAS tool to accelerate plant breeding

    Directory of Open Access Journals (Sweden)

    Jiangfeng eHe

    2014-09-01

    Full Text Available Marker-assisted selection (MAS refers to the use of molecular markers to assist phenotypic selections in crop improvement. Several types of molecular markers, such as single nucleotide polymorphism (SNP, have been identified and effectively used in plant breeding. The application of next-generation sequencing (NGS technologies has led to remarkable advances in whole genome sequencing, which provides ultra-throughput sequences to revolutionize plant genotyping and breeding. To further broaden NGS usages to large crop genomes such as maize and wheat, genotyping by sequencing (GBS has been developed and applied in sequencing multiplexed samples that combine molecular marker discovery and genotyping. GBS is a novel application of NGS protocols for discovering and genotyping SNPs in crop genomes and populations. The GBS approach includes the digestion of genomic DNA with restriction enzymes followed by the ligation of barcode adapter, PCR amplification and sequencing of the amplified DNA pool on a single lane of flow cells. Bioinformatic pipelines are needed to analyze and interpret GBS datasets. As an ultimate MAS tool and a cost-effective technique, GBS has been successfully used in implementing genome-wide association study (GWAS, genomic diversity study, genetic linkage analysis, molecular marker discovery and genomic selection (GS under a large scale of plant breeding programs.

  9. Genotyping-by-sequencing (GBS), an ultimate marker-assisted selection (MAS) tool to accelerate plant breeding.

    Science.gov (United States)

    He, Jiangfeng; Zhao, Xiaoqing; Laroche, André; Lu, Zhen-Xiang; Liu, HongKui; Li, Ziqin

    2014-01-01

    Marker-assisted selection (MAS) refers to the use of molecular markers to assist phenotypic selections in crop improvement. Several types of molecular markers, such as single nucleotide polymorphism (SNP), have been identified and effectively used in plant breeding. The application of next-generation sequencing (NGS) technologies has led to remarkable advances in whole genome sequencing, which provides ultra-throughput sequences to revolutionize plant genotyping and breeding. To further broaden NGS usages to large crop genomes such as maize and wheat, genotyping-by-sequencing (GBS) has been developed and applied in sequencing multiplexed samples that combine molecular marker discovery and genotyping. GBS is a novel application of NGS protocols for discovering and genotyping SNPs in crop genomes and populations. The GBS approach includes the digestion of genomic DNA with restriction enzymes followed by the ligation of barcode adapter, PCR amplification and sequencing of the amplified DNA pool on a single lane of flow cells. Bioinformatic pipelines are needed to analyze and interpret GBS datasets. As an ultimate MAS tool and a cost-effective technique, GBS has been successfully used in implementing genome-wide association study (GWAS), genomic diversity study, genetic linkage analysis, molecular marker discovery and genomic selection under a large scale of plant breeding programs.

  10. Orchidopexy san ligation technique of orchidopexy | Jain | African ...

    African Journals Online (AJOL)

    Herniotomy is performed for the surgical repair of hernia and along with orchiopexy for the closure of associated patent processus vaginalis. Traditionally, ligation of hernial sac during orchiopexy is considered mandatory to prevent postoperative development of hernia. The present report was designed to study the results of ...

  11. Evaluation of mesenteric lymphangiography and thoracic duct ligation in cats with chylothorax: 19 cases (1987-1992)

    International Nuclear Information System (INIS)

    Kerpsack, S.J.; McLoughlin, M.A.; Birchard, S.J.; Smeak, D.D.; Biller, D.S.

    1994-01-01

    Mesenteric lymphangiography and thoracic duct ligation were performedon 19 cats with chylothorax between 1987 to 1992. Chylothorax was diagnosed on the basis of detection of chylomicrons in the pleural effusion or determination of a cholesterol concentration:triglyceride concentration ratio of 12 months after surgery. Four cats died between 2 and 13 days after thoracic duct ligation, but pleural effusion had resolved in 3 of these 4 cats at the time of death. Five cats were euthanatized 8 to 36 days after surgery because of persistent chylous effusion after thoracic duct ligation

  12. CMOS Current-mode Operational Amplifier

    OpenAIRE

    Kaulberg, Thomas

    1992-01-01

    A fully differential-input differential-output current-mode operational amplifier (COA) is described. The amplifier utilizes three second generation current-conveyors (CCII) as the basic building blocks. It can be configured to provide either a constant gain-bandwidth product in a fully balanced current-mode feedback amplifier or a constant bandwidth in a transimpedance feedback amplifier. The amplifier is found to have a gain bandwidth product of 8 MHz, an offset current of 0.8 ¿A (signal-r...

  13. Rubber band ligation and infrared photocoagulation for the outpatient treatment of hemorrhoidal disease

    OpenAIRE

    Ricci,Maurício Pichler; Matos,Délcio; Saad,Sarhan Sydney

    2008-01-01

    PURPOSE: To compare the results of rubber band ligation and infrared photocoagulation for the treatment of hemorrhoidal disease through the analysis of the incidence of complications after each treatment and respective success rate. METHODS: Forty-eight patients with first, second or third degree hemorrhoidal disease were randomized to recieve treatment with either rubber band ligation (n=23) or infrared photocoagulation (n=25). Each patient was assessed at 1 week and 4 week intervals after t...

  14. Idiopathic chylopericardium treated by percutaneous thoracic duct embolization after failed surgical thoracic duct ligation

    Energy Technology Data Exchange (ETDEWEB)

    Courtney, Malachi; Ayyagari, Raj R. [Yale School of Medicine, Yale New Haven Hospital, New Haven, CT (United States); Division of Interventional Radiology, Department of Radiology, 789 Howard Avenue, P.O. Box 208042, New Haven, CT (United States)

    2015-06-15

    Chylopericardium rarely occurs in pediatric patients, but when it does it is most often a result of lymphatic injury during cardiothoracic surgery. Primary idiopathic chylopericardium is especially rare, with few cases in the pediatric literature. We report a 10-year-old boy who presented with primary idiopathic chylopericardium after unsuccessful initial treatment with surgical lymphatic ligation and creation of a pericardial window. Following readmission to the hospital for a right-side chylothorax resulting from the effluent from the pericardial window, he had successful treatment by interventional radiology with percutaneous thoracic duct embolization. This case illustrates the utility of thoracic duct embolization as a less-invasive alternative to surgical thoracic duct ligation, or as a salvage procedure when surgical ligation fails. (orig.)

  15. Idiopathic chylopericardium treated by percutaneous thoracic duct embolization after failed surgical thoracic duct ligation

    International Nuclear Information System (INIS)

    Courtney, Malachi; Ayyagari, Raj R.

    2015-01-01

    Chylopericardium rarely occurs in pediatric patients, but when it does it is most often a result of lymphatic injury during cardiothoracic surgery. Primary idiopathic chylopericardium is especially rare, with few cases in the pediatric literature. We report a 10-year-old boy who presented with primary idiopathic chylopericardium after unsuccessful initial treatment with surgical lymphatic ligation and creation of a pericardial window. Following readmission to the hospital for a right-side chylothorax resulting from the effluent from the pericardial window, he had successful treatment by interventional radiology with percutaneous thoracic duct embolization. This case illustrates the utility of thoracic duct embolization as a less-invasive alternative to surgical thoracic duct ligation, or as a salvage procedure when surgical ligation fails. (orig.)

  16. Management of IVC Injury: Repair or Ligation? A Propensity Score Matching Analysis Using the National Trauma Data Bank.

    Science.gov (United States)

    Matsumoto, Shokei; Jung, Kyoungwon; Smith, Alan; Coimbra, Raul

    2018-03-01

    Ligation can be used as part of damage-control operations under critical conditions after IVC injury. Inferior vena cava ligation could potentially yield greater survival benefit compared with repair after injury. We hypothesized that ligation significantly improves outcomes compared with repair. The National Trauma Data Bank dataset for 2007-2014 was reviewed. Eligible patients included those sustaining IVC injury who underwent surgical ligation or repair. Data on demographics, outcomes, and complications were collected. Comparative analysis of demographic characteristics, complications and outcomes were performed. There were 4,865 patients identified in the National Trauma Data Bank with IVC injury. A total of 1,316 patients met inclusion criteria. Four hundred and forty-seven patients (34.0%) underwent ligation and 869 (66.0%) underwent repair. Before matching, the ligation group was sicker than the repair group and the in-hospital mortality was significantly higher in the ligation group (43.8% vs 36.2%; odds ratio [OR] 1.37; 95% CI 1.09 to 1.73). One to one propensity score matching generated 310 pairs. After propensity score matching, in-hospital mortality was similar (41.3% vs 39.0%; OR 1.10; 95% CI 0.80 to 1.52). However, IVC ligation was associated with significantly higher complication rates of extremity compartment syndrome (OR 5.23; 95% CI 1.50 to 18.24), pneumonia (OR 1.76; 95% CI 1.08 to 2.86), deep venous thrombosis (OR 2.83 95% CI 1.70 to 4.73), pulmonary embolism (OR 3.63; 95% CI 1.18 to 11.17), and longer hospital length of stay (17.0 days [interquartile range 1.0 to 35.0 days] vs 9.0 days [interquartile range 1.0 to 22.0 days]; p = 0.002). Inferior vena cava ligation is not superior to repair in terms of decreasing mortality in patients with IVC injury, but it is associated with higher complication rates and hospital LOS. Copyright © 2018 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Increased secretion of insulin and proliferation of islet {beta}-cells in rats with mesenteric lymph duct ligation

    Energy Technology Data Exchange (ETDEWEB)

    Nagino, Ko; Yokozawa, Junji; Sasaki, Yu; Matsuda, Akiko; Takeda, Hiroaki [Department of Gastroenterology, Faculty of Medicine, Yamagata University, Yamagata 990-9585 (Japan); Kawata, Sumio, E-mail: Sumio_Kawata@pref.hyogo.lg.jp [Department of Gastroenterology, Faculty of Medicine, Yamagata University, Yamagata 990-9585 (Japan); Hyogo Prefectural Nishinomiya Hospital, 13-9 Rokutanji-cho, Nishinomiya 662-0918 (Japan)

    2012-08-24

    Highlights: Black-Right-Pointing-Pointer Insulin secretion was increased during the OGTT or IVGTT in mesenteric lymph duct-ligated rats. Black-Right-Pointing-Pointer Proliferation of islet {beta}-cells was upregulated in lymph duct-ligated rats. Black-Right-Pointing-Pointer Mesenteric lymph duct flow has a role in glucose metabolism. -- Abstract: Background and aims: It has been suggested that intestinal lymph flow plays an important role in insulin secretion and glucose metabolism after meals. In this study, we investigated the influence of ligation of the mesenteric lymph duct on glucose metabolism and islet {beta}-cells in rats. Methods: Male Sprague-Dawley rats (10 weeks old) were divided into two groups: one underwent ligation of the mesenteric lymph duct above the cistern (ligation group), and the other underwent a sham operation (sham group). After 1 and 2 weeks, fasting plasma concentrations of glucose, insulin, triglyceride, glucose-dependent insulinotropic polypeptide (GIP), and the active form of glucagon-like peptide-1 (GLP-1) were measured. At 2 weeks after the operation, the oral glucose tolerance test (OGTT) and intravenous glucose tolerance test (IVGTT) were performed. After the rats had been sacrificed, the insulin content of the pancreas was measured and the proliferation of {beta}-cells was assessed immunohistochemically using antibodies against insulin and Ki-67. Results: During the OGTT, the ligation group showed a significant decrease in the plasma glucose concentration at 120 min (p < 0.05) and a significant increase in the plasma insulin concentration by more than 2-fold at 15 min (p < 0.01). On the other hand, the plasma GIP concentration was significantly decreased at 60 min (p < 0.01) in the ligated group, while the active form of GLP-1 showed a significantly higher level at 90 min (1.7-fold; p < 0.05) and 120 min (2.5-fold; p < 0.01). During the IVGTT, the plasma insulin concentration in the ligation group was significantly higher at 2

  18. Rapid tyrosine phosphorylation of Lck following ligation of the tumor-associated cell surface molecule A6H

    DEFF Research Database (Denmark)

    Labuda, T; Gerwien, J; Ødum, Niels

    1999-01-01

    and the TCR-CD3 complex takes place and which signaling pathway might be involved. Here we show that ligation of the A6H antigen with mAb induces tyrosine phosphorylation of the Lck protein tyrosine kinase (PTK). Co-ligation of the A6H antigen with CD3 resulted in augmented Lck phosphorylation and mitogenesis....... In addition, A6H ligation induced an up-regulation of CD3-mediated phosphorylation of the 23 kDa high mol. wt form of TCR zeta and the zeta-associated protein, ZAP-70. Co-precipitation of Lck and ZAP-70 was only seen in T cells activated by combined A6H and anti-CD3 stimulation. In contrast, another Src...... family PTK, Fyn, was not affected by A6H ligation. In conclusion, we now demonstrate, for the first time, that A6H ligation triggers Lck phosphorylation, and that cross-talk between A6H and the TCR-CD3 complex involves Lck, ZAP-70 and the slow migrating isoform of TCR zeta. These results further suggests...

  19. Application of amplified fragment length polymorphism (AFLPs) for ...

    African Journals Online (AJOL)

    Uapaca kirkiana Muell. Årg is a dioecious fruit tree species for priority domestication in Southern Africa. It reaches reproductive maturity in eight to ten years with male plants making up 50% of breeding populations. Early identification of sex of seedlings is a prerequisite for selection and tree improvement. The amplified ...

  20. Root resorption during orthodontic treatment with self-ligating or conventional brackets: a systematic review and meta-analysis.

    Science.gov (United States)

    Yi, Jianru; Li, Meile; Li, Yu; Li, Xiaobing; Zhao, Zhihe

    2016-11-21

    The aim of this study was to compare the external apical root resorption (EARR) in patients receiving fixed orthodontic treatment with self-ligating or conventional brackets. Studies comparing the EARR between orthodontic patients using self-ligating or conventional brackets were identified through electronic search in databases including CENTRAL, PubMed, EMBASE, China National Knowledge Infrastructure (CNKI) and SIGLE, and manual search in relevant journals and reference lists of the included studies until Apr 2016. The extraction of data and risk of bias evaluation were conducted by two investigators independently. The original outcome underwent statistical pooling by using Review Manager 5. Seven studies were included in the systematic review, out of which, five studies were statistically pooled in meta-analysis. The value of EARR of maxillary central incisors in the self-ligating bracket group was significantly lower than that in the conventional bracket group (SMD -0.31; 95% CI: -0.60--0.01). No significant differences in other incisors were observed between self-ligating and conventional brackets. Current evidences suggest self-ligating brackets do not outperform conventional brackets in reducing the EARR in maxillary lateral incisors, mandible central incisors and mandible lateral incisors. However, self-ligating brackets appear to have an advantage in protecting maxillary central incisor from EARR, which still needs to be confirmed by more high-quality studies.

  1. Papillary Cystadenoma: An Incidental Finding in Tubal Ligation

    Directory of Open Access Journals (Sweden)

    Tabitha Lynn Ward

    2018-01-01

    Full Text Available von Hippel-Lindau disease (vHLD is a rare autosomal dominant disorder with multiple benign and malignant tumors of different organs. We report a papillary cystadenoma of the mesosalpinx found in close association with an adenomatoid tumor discovered incidentally following tubal ligation in a patient with vHLD.

  2. How I do it: surgical ligation of craniocervical junction dural AV fistulas.

    Science.gov (United States)

    Sorenson, Thomas J; La Pira, Biagia; Hughes, Joshua; Lanzino, Giuseppe

    2017-08-01

    Dural arteriovenous fistulas (DAVFs) of the craniocervical junction are uncommon vascular lesions, which often require surgical treatment even in the endovascular era. Most commonly, the fistula is placed laterally, and surgical ligation is performed through a lateral suboccipital craniotomy. After dural opening, the area is inspected, and the arterialized vein is identified emerging from the dura, often adjacent to the entry point of the vertebral artery, and ligated. A far lateral craniotomy is the authors' preferred surgical approach for accessing and treating dural arteriovenous fistulas of the craniocervical junction that cannot be reached endovascularly.

  3. Role of lubricants on friction between self-ligating brackets and archwires.

    Science.gov (United States)

    Leal, Renata C; Amaral, Flávia L B; França, Fabiana M G; Basting, Roberta T; Turssi, Cecilia P

    2014-11-01

    To evaluate the effect of different lubricants on friction between orthodontic brackets and archwires. Active (Quick, Forestadent) and passive (Damon 3MX, Ormco) self-ligating brackets underwent friction tests in the presence of mucin- and carboxymethylcellulose (CMC)-based artificial saliva, distilled water, and whole human saliva (positive control). Dry friction (no lubricant) was used as the negative control. Bracket/wire samples (0.014 × 0.025 inch, CuNiTi, SDS Ormco) underwent friction tests eight times in a universal testing machine. Two-way analysis of variance showed no significant interaction between bracket type and lubricant (P  =  .324). Friction force obtained with passive self-ligating brackets was lower than that for active brackets (P Friction observed in the presence of artificial saliva did not differ from that generated under lubrication with natural human saliva, as shown by Tukey test. Higher friction forces were found with the use of distilled water or when the test was performed under dry condition (ie, with no lubricant). Lubrication plays a role in friction forces between self-ligating brackets and CuNiTi wires, with mucin- and CMC-based artificial saliva providing a reliable alternative to human natural saliva.

  4. Hypotension following patent ductus arteriosus ligation: the role of adrenal hormones.

    Science.gov (United States)

    Clyman, Ronald I; Wickremasinghe, Andrea; Merritt, T Allen; Solomon, Tabitha; McNamara, Patrick; Jain, Amish; Singh, Jaideep; Chu, Alison; Noori, Shahab; Sekar, Krishnamurthy; Lavoie, Pascal M; Attridge, Joshua T; Swanson, Jonathan R; Gillam-Krakauer, Maria; Reese, Jeff; DeMauro, Sara; Poindexter, Brenda; Aucott, Sue; Satpute, Monique; Fernandez, Erika; Auchus, Richard J

    2014-06-01

    To test the hypothesis that an impaired adrenal response to stress might play a role in the hypotension that follows patent ductus arteriosus (PDA) ligation. We performed a multicenter study of infants born at 15. Of 95 infants enrolled, 43 (45%) developed hypotension and 14 (15%) developed catecholamine-resistant hypotension. Low postoperative cortisol levels were not associated with the overall incidence of hypotension after ligation. However, low cortisol levels were associated with the refractoriness of the hypotension to catecholamine treatment. In a multivariate analysis: the OR for developing catecholamine-resistant hypotension was OR 36.6, 95% CI 2.8-476, P = .006. Low cortisol levels (in infants with catecholamine-resistant hypotension) were not attributable to adrenal immaturity or impairment; their cortisol precursor concentrations were either low or unchanged, and their response to cosyntropin was similar to infants without catecholamine-resistant hypotension. Infants with low cortisol concentrations after PDA ligation are likely to develop postoperative catecholamine-resistant hypotension. We speculate that decreased adrenal stimulation, rather than an impaired adrenal response to stimulation, may account for the decreased production. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. The importance of the ligation of the inferior thyroid artery in parathyroid function after subtotal thyroidectomy

    Directory of Open Access Journals (Sweden)

    Araujo Filho Vergilius José Furtado de

    2000-01-01

    Full Text Available We prospectively studied the effects of the ligation of the inferior thyroid artery (ITA on postoperative hypoparathyroidism in 48 patients who underwent functional subtotal thyroidectomy. Patients were randomized into two groups: A, with bilateral ligation of the ITA and B, without ligation of the ITA. Parathyroid function was checked preoperatively and after surgery by clinical examination and measurement of total calcium, intact PTH, urinary calcium, and AMPc. RESULTS: A significant incidence of postoperative hypocalcemia occurred: 17% in group A and 13% in B on the 4th postoperative day. Six months later, the incidence was 5% in Group A and 0% in Group B. These differences were not statistically significant between the two groups, and neither were any of the other clinical and laboratory observations. CONCLUSION: The ligation of the ITA was not an important causal factor for the occurrence of postoperative hypocalcemia after subtotal thyroidectomy.

  6. Banding ligation versus no intervention for primary prevention in adults with oesophageal varices

    DEFF Research Database (Denmark)

    Yong, Charles Wei Kit; Vadera, Sonam; Morgan, Marsha Y.

    2017-01-01

    This is a protocol for a Cochrane Review (Intervention). The objectives are as follows: To assess the beneficial and harmful effects of banding ligation versus no intervention in adults with cirrhosis and gastro-oesophageal varices that have not bled.......This is a protocol for a Cochrane Review (Intervention). The objectives are as follows: To assess the beneficial and harmful effects of banding ligation versus no intervention in adults with cirrhosis and gastro-oesophageal varices that have not bled....

  7. Ligation of lymph vessels for the treatment of recurrent inguinal lymphoceles following lymphadenectomy

    DEFF Research Database (Denmark)

    Toyserkani, Navid Mohamadpour; Nielsen, Henrik Toft; Bakholdt, Vivi

    2016-01-01

    BACKGROUND: Recurrent lymphocele following groin dissection is generally a self-limiting condition, but in a few cases, the lymphocele persists and for this, there are not many options. Few reports have proposed the efficacy of lymph vessel ligation with patent blue as a vessel locator. We have......, and their data was retrieved from electronic patient records. RESULTS: In total, eight patients had this procedure performed for a total of ten inguinal regions. In all regions, leaking lymph vessels were easily found by the blue color and a median of 3 (range 1-5 vessels) vessels per region were ligated using...... and had the procedure performed again with immediate effect. CONCLUSIONS: Ligation of lymph vessels for the treatment of recurrent inguinal lymphoceles appears to be an appropriate treatment modality that is both quick and easy to perform with minimum risk, and in most cases, it results in immediate...

  8. Improved-Bandwidth Transimpedance Amplifier

    Science.gov (United States)

    Chapsky, Jacob

    2009-01-01

    The widest available operational amplifier, with the best voltage and current noise characteristics, is considered for transimpedance amplifier (TIA) applications where wide bandwidth is required to handle fast rising input signals (as for time-of-flight measurement cases). The added amplifier inside the TIA feedback loop can be configured to have slightly lower voltage gain than the bandwidth reduction factor.

  9. Preoperative embolization for juvenile nasopharyngeal angiofibroma. Usefulness of IADSA and problems of external carotid ligation

    Energy Technology Data Exchange (ETDEWEB)

    Saitoh, Ryuichi; Nakagawa, Nobuo; Kohrogi, Yukinori; Izunaga, Hiroshi; Bussaka, Hiromasa; Miyawaki, Masayuki; Takahashi, Mutsumasa; Ikawa, Tsutomu; Ishikawa, Takashi (Kumamoto Univ. (Japan). School of Medicine)

    1984-10-01

    Three male cases of juvenile nasopharyngeal angiofibroma are presented. Satisfactory results were obtained by performing preoperative embolization combined with intraarterial digital subtraction angiography (IADSA) in two of them. The other case had undergone external carotid ligation. Usefulness of IADSA in performing preoperative embolization for this disease and problems of external carotid ligation are discussed.

  10. Millimeter-wave power amplifiers

    CERN Document Server

    du Preez, Jaco

    2017-01-01

    This book provides a detailed review of millimeter-wave power amplifiers, discussing design issues and performance limitations commonly encountered in light of the latest research. Power amplifiers, which are able to provide high levels of output power and linearity while being easily integrated with surrounding circuitry, are a crucial component in wireless microwave systems. The book is divided into three parts, the first of which introduces readers to mm-wave wireless systems and power amplifiers. In turn, the second focuses on design principles and EDA concepts, while the third discusses future trends in power amplifier research. The book provides essential information on mm-wave power amplifier theory, as well as the implementation options and technologies involved in their effective design, equipping researchers, circuit designers and practicing engineers to design, model, analyze, test and implement high-performance, spectrally clean and energy-efficient mm-wave systems.

  11. Incorporation of selenomethionine into proteins through selenohomocysteine-mediated ligation

    NARCIS (Netherlands)

    Roelfes, G; Hilvert, D

    2003-01-01

    The chemical synthesis of moderate-sized proteins has benefited enormously from the development of chemoselective methods for the ligation of peptide fragments. In this regard, the reaction of peptide thioesters with peptides containing an N-terminal cysteine has proved particularly powerful. The

  12. End-Point Immobilization of Recombinant Thrombomodulin via Sortase-Mediated Ligation

    Science.gov (United States)

    Jiang, Rui; Weingart, Jacob; Zhang, Hailong; Ma, Yong; Sun, Xue-Long

    2012-01-01

    We report an enzymatic end-point modification and immobilization of recombinant human thrombomodulin (TM), a cofactor for activation of anticoagulant protein C pathway via thrombin. First, a truncated TM mutant consisting of epidermal growth factor-like domains 4–6 (TM456) with a conserved pentapeptide LPETG motif at its C-terminal was expressed and purified in E. coli. Next, the truncated TM456 derivative was site-specifically modified with N-terminal diglycine containing molecules such as biotin and the fluorescent probe dansyl via sortase A (SrtA) mediated ligation (SML). The successful ligations were confirmed by SDS-PAGE and fluorescence imaging. Finally, the truncated TM456 was immobilized onto N-terminal diglycine-functionalized glass slide surface via SML directly. Alternatively, the truncated TM456 was biotinylated via SML and then immobilized onto streptavidin-functionalized glass slide surface indirectly. The successful immobilizations were confirmed by fluorescence imaging. The bioactivity of the immobilized truncated TM456 was further confirmed by protein C activation assay, in which enhanced activation of protein C by immobilized recombinant TM was observed. The sortase A-catalyzed surface ligation took place under mild conditions and is rapid occurring in a single step without prior chemical modification of the target protein. This site-specific covalent modification leads to molecules being arranged in a definitively ordered fashion and facilitating the preservation of the protein’s biological activity. PMID:22372933

  13. Oscillators and operational amplifiers

    OpenAIRE

    Lindberg, Erik

    2005-01-01

    A generalized approach to the design of oscillators using operational amplifiers as active elements is presented. A piecewise-linear model of the amplifier is used so that it make sense to investigate the eigenvalues of the Jacobian of the differential equations. The characteristic equation of the general circuit is derived. The dynamic nonlinear transfer characteristic of the amplifier is investigated. Examples of negative resistance oscillators are discussed.

  14. FLUIDIC AC AMPLIFIERS.

    Science.gov (United States)

    Several fluidic tuned AC Amplifiers were designed and tested. Interstage tuning and feedback designs are considered. Good results were obtained...corresponding Q’s as high as 12. Element designs and test results of one, two, and three stage amplifiers are presented. AC Modulated Carrier Systems

  15. Management of Small Urethrocutaneous Fistula by Tight Ligation ...

    African Journals Online (AJOL)

    After identifying the fistulous opening, the fistula tract was circumferentially and meticulously dissected ,then the dissected tract was lifted up and the base was ligated tightly with 5/0 vicryl, the external epithelium of the dissected tract was fulgurated with the diathermy, then a second layer of local soft tissue was secured over ...

  16. The effectiveness of Doppler controlled hemorrhoidal artery ligation ...

    African Journals Online (AJOL)

    In this work, we discuss the preliminary results of the effectiveness of the hemorrhoidal artery ligation under control Doppler as a new technique for the treatment of hemorrhoids. We report the results of patients with hemorrhoids we have followed over a period of one year who were treated with HAL Doppler. The intra-and ...

  17. Sortase-Mediated Ligation of Purely Artificial Building Blocks

    Directory of Open Access Journals (Sweden)

    Xiaolin Dai

    2018-02-01

    Full Text Available Sortase A (SrtA from Staphylococcus aureus has been often used for ligating a protein with other natural or synthetic compounds in recent years. Here we show that SrtA-mediated ligation (SML is universally applicable for the linkage of two purely artificial building blocks. Silica nanoparticles (NPs, poly(ethylene glycol and poly(N-isopropyl acrylamide are chosen as synthetic building blocks. As a proof of concept, NP–polymer, NP–NP, and polymer–polymer structures are formed by SrtA catalysis. Therefore, the building blocks are equipped with the recognition sequence needed for SrtA reaction—the conserved peptide LPETG—and a pentaglycine motif. The successful formation of the reaction products is shown by means of transmission electron microscopy (TEM, matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-ToF MS, and dynamic light scattering (DLS. The sortase catalyzed linkage of artificial building blocks sets the stage for the development of a new approach to link synthetic structures in cases where their synthesis by established chemical methods is complicated.

  18. Switched diversity strategies for dual-hop amplify-and-forward relaying systems

    KAUST Repository

    Gaaloul, Fakhreddine; Radaydeh, Redha Mahmoud Mesleh; Alouini, Mohamed-Slim

    2012-01-01

    This study investigates different receive single-branch switch-based diversity schemes for dual-hop amplify-and-forward relaying networks. Specifically, three receive processing algorithms are adopted, in which the receive branch is selected using

  19. Comparison between Ultroid and Rubber Band Ligation in Treatment of Internal Hemorrhoids

    Directory of Open Access Journals (Sweden)

    Rasoul Azizi

    2010-11-01

    Full Text Available "nHemorrhoid is one of the most common surgical diseases and different methods are available for its treatment. This study is a comparison between two methods of treatment of internal hemorrhoid, Monopolar low voltage instrument (Ultroid and Rubber Band Ligation. This method has been carried out prospectively in which 50 patients who were treated with rubber band ligation and 50 patients with Ultroid were compared according to the incidence of complications, post-operative pain and treatment response. According to this study complete success rate with Ultroid was 82% and partial success rate was 10% and no response to treatment was seen in 8%. In Rubber Band method the complete response rate was 94% (P=0.2. With Ultroid, 74% of patient reported no postoperative pain, 24% reported mild and moderate pain and 2% of patients complained of severe pain. With Rubber band ligation, 72% of patients reported no post-operative pain, 26% reported mild and moderate pain and 1% complained of severe pain (P=0.00. Rubber Band ligation and Ultroid are both considered as outpatient procedures for treatment of hemorrhoids. Both methods are mostly used for grade 1, 2 and sometime grade 3 hemorrhoids. In Ultroid method the operator is required to hold the probe for a period of time, and in most cases, the surgeon should spend between 20-25 minutes for the coagulation of three piles. Some surgeons do not have patience for this modality of internal hemorrhoid treatment. In this study we achieved acceptable results comparable with those of other techniques.

  20. Evaluation of friction produced by self-ligating, conventional and Barbosa Versatile brackets

    Directory of Open Access Journals (Sweden)

    Jurandir Antonio BARBOSA

    Full Text Available Abstract Introduction The Barbosa Versatile bracket design may provide lower frictional force and greater sliding. However, no in vitro studies have shown its sliding mechanisms and frictional resistance, particularly in comparison with other self-ligating or conventional brackets. Objective To compare the frictional resistance among self-ligating brackets (EasyClip/ Aditek, Damon MX/ Ormco and In Ovation R/ GAC; conventional brackets (Balance Roth/ GAC, and Roth Monobloc/ Morelli; and Barbosa Versatile bracket (Barbosa Versatile/ GAC with different angles and arch wires. Material and method Brackets were tested with the 0.014", 0.018", 0.019"×0.025" and 0.021"×0.025" stainless steel wires, with 0, 5, 10, 15 and 20 degree angulations. Tying was performed with elastomeric ligature for conventional and Barbosa Versatile brackets, or with a built-in clip system of the self-ligating brackets. A universal testing machine was used to obtain sliding strength and friction value readouts between brackets and wires. Result Three-way factorial ANOVA 4×5×6 (brackets × angulation × wire and Tukey tests showed statistically significant differences for all factors and all interactions (p<0.0001. Static frictional resistance showed a lower rate for Barbosa Versatile bracket and higher rates for Roth Monobloc and Balance brackets. Conclusion The lowest frictional resistance was obtained with the Barbosa Versatile bracket and self-ligating brackets in comparison with the conventional type. Increasing the diameter of the wires increased the frictional resistance. Smaller angles produced less frictional resistance.

  1. Selection and optimization of spectrometric amplifiers for gamma spectrometry: part II - linearity, live time correction factors and software

    International Nuclear Information System (INIS)

    Moraes, Marco Antonio Proenca Vieira de; Pugliesi, Reinaldo

    1996-01-01

    The objective of the present work was to establish simple criteria to choose the best combination of electronic modules to achieve an adequate high resolution gamma spectrometer. Linearity, live time correction factors and softwares of a gamma spectrometric system composed by a Hp Ge detector have been studied by using several kinds of spectrometric amplifiers: Canberra 2021, Canberra 2025, Ortec 673 and Tennelec 244 and the MCA cards Ortec and Nucleus. The results showed low values of integral non-linearity for all spectrometric amplifiers connected to the Ortec and Nucleus boards. The MCA card should be able to correct amplifier dead time for 17 kcps count rates. (author)

  2. Intraabdominal laparoscopy-assisted "open" vessel ligation of testicular vessels: a potential treatment for varicocele.

    Science.gov (United States)

    Miyano, Go; Miyahara, Katsumi; Halibieke, Abudebieke; Lane, Geoffrey J; Okazaki, Tadaharu; Yamataka, Atsuyuki

    2011-10-01

    We tested our laparoscopy-assisted "open" ligation (LOL) technique on testicular vessels. We ligated the left testicular artery and vein (TAV) in 8-week-old male Wister rats using LOL (LOL group; n=10) or laparotomy (open group; n=10). In LOL, a 0-degree laparoscope was introduced through a 5-mm epigastric trocar. A 3-mm grasper was used to expose the left TAV. A lapa-her-closure (LHC) needle loaded with 3-0 SurgiPro was directly inserted into the left lower quadrant where the left TAV should be and advanced under the vessels, and the suture material was released leaving one end outside. The LHC was then withdrawn a little and advanced again over the vessels to grasp the end of the suture material just released to bring it outside. This was proximally repeated. The two ends of both sutures were conventionally tied outside, and the knot was passed through the insertion site and tightened around the vessels. In the open group, the left TAV were ligated using two 3-0 SurgiPro ties. In both groups, the right side was left intact. All rats were sacrificed 2 weeks postoperatively, and both testes were examined with hematoxylin and eosin. Treatment time was 5-7 minutes for LOL and 7-8 minutes for the open group. Postoperative recovery was uneventful. No adhesions were present between the ligated vessels and bowel in any rat. Histopathology of all left testes showed coagulative necrosis of germinal cells and seminiferous tubules; all right testes were normal. LOL appears to be as effective as open ligation and may find application for treating varicocele.

  3. Extrahepatic portal venous obstruction: The effects of early ligation of splenic artery during splenectomy

    Directory of Open Access Journals (Sweden)

    Gazula Suhasini

    2009-01-01

    Full Text Available Aim: To objectively demonstrate the gain in blood volume and blood components following early ligation of splenic artery during splenectomy and splenorenal shunts in children with extra hepatic portal venous obstruction (EHPVO. Methods: Twenty-eight children (20 males and 8 females, mean age: 9.9 (±3.2 years with EHPVO and hypersplenism were recruited. We followed a protocol of systematically locating and ligating the splenic artery first, followed by a 30-minute waiting period to allow the massive spleen to decongest via the splenic vein and venous collaterals and then completing the splenectomy by standard procedure. No intravenous fluid was administered during this 30-minute period. Blood samples were drawn just prior to splenic artery ligation and soon after splenectomy for the estimation of hematological and biochemical parameters. Results: We noticed a highly significant increase in the hemoglobin, hematocrit, leukocyte, platelet, and RBC counts by early ligation of the splenic artery (p < 0.0004. The gain in hemoglobin and hematocrit was equivalent to a transfusion of atleast 100-150 ml of packed RBC. The increase in platelet count was equivalent to a platelet transfusion of atleast 4 units of platelet concentrates in an adult. There is a positive correlation between the splenic weight and the platelet gain (p= 0.0568 and the splenic volume on preoperative imaging and the platelet gain (p= 0.0251. Conclusion: Early ligation of the splenic artery during splenectomy results in passive splenic decongestion and thereby a significant gain in blood components. This protocol appears to be a feasible blood conservation method to avoid blood transfusions in this group of hypersplenic EHPVO patients.

  4. Comparison of infrared coagulation and rubber band ligation for first and second degree haemorrhoids: a randomised prospective clinical trial.

    Science.gov (United States)

    Templeton, J L; Spence, R A; Kennedy, T L; Parks, T G; Mackenzie, G; Hanna, W A

    1983-01-01

    One hundred and thirty seven previously untreated out-patients with first and second degree haemorrhoids were allocated at random to treatment by infrared coagulation (n=66) or rubber band ligation (n=71). Complete follow up was obtained in 122 patients (60 who had undergone infrared coagulation (group 1), and 62 rubber band ligation (group 2)) at periods from three months to one year after completion of treatment. Infrared coagulation produced a satisfactory outcome in 51 patients (85%): 34 were rendered asymptomatic and 17 improved. Rubber band ligation produced a satisfactory outcome in 57 patients (92%): 33 were rendered asymptomatic and 24 improved. Both methods were equally effective in first and second degree haemorrhoids. The incidence of side effects, particularly discomfort, during and after treatment was significantly higher in those treated by rubber band ligation (p less than 0.001). This appeared to be an appreciable deterrent to future patient compliance. The number of patients losing more than 24 hours from work was higher after rubber band ligation than after infrared coagulation. The number of treatments necessary to cure symptoms did not differ significantly between the two methods. Infrared coagulation was significantly faster than rubber band ligation (p less than 0.001). Infrared coagulation is a simple, fast, and effective outpatient method for the treatment of first and second degree haemorrhoids with fewer troublesome side effects and higher patient acceptability than rubber band ligation. PMID:6404471

  5. Optimal primary surgical management of infected pseudoaneurysm in intravenous drug abusers: ligation or reconstruction?

    International Nuclear Information System (INIS)

    Jamil, M.; Usman, R.; Afzal, M.; Malik, N.I.

    2017-01-01

    Objective: To find out the optimal primary surgical treatment options for infected pseudoaneurysm in intravenous drug abusers. Study Design: Cross sectional descriptive study. Place and Duration of Study: Department of Vascular Surgery, Combined Military Hospital Lahore, from Jan 2010 to Jun 2015. Material and Methods: A total of 31 consecutive patients with a history of intravenous drug abuse and an infected pseudoaneurysm in the groin or elbow, presenting in emergency department; were included in this study. All patients were primarily treated with ligation of the artery, excision of infected pseudoaneurysm and debridement of necrotic tissues. Only one patient underwent additional revascularization procedure. Results: All patients who underwent ligation and excision procedures did well initially. One (3.2%) patient developed severe distal ischemia after ligation of femoral artery within first 24 hours, so extra anatomic revascularization procedure was performed. Five (16.1%) patients required revascularization procedure after 16 weeks due to disabling distal ischemia. No amputation was needed and mortality rate was zero. Conclusion: Primary ligation of the artery with excision of infected pseudoaneurysm and necrotic material was found the optimal initial management for infected pseudoaneurysm in intravenous drug addicts. Ischemic complications if develop should be treated with early or late revascularization.

  6. Early or Late Surgical Ligation of Medical Refractory Patent Ductus Arteriosus in Premature Infants

    Directory of Open Access Journals (Sweden)

    Chien-Chou Hsiao

    2009-01-01

    Full Text Available Optimal time to surgical ligation of patent ductus arteriosus (PDA in very-low-birth-weight ( 14 days groups. Basic clinical features, major morbidity of prematurity and mortality were compared. Clinical features and major outcomes were similar. The early ligation group had earlier onset of symptomatic PDA (5.7 ± 1.6 days vs. 8.1 ± 3.6 days, p = 0.024, and fewer days of total parenteral nutrition (TPN (39.6 ± 13.9 days vs. 60.4 ± 31.4 days, p = 0.025 and ventilator use (11.1 ± 6.7 days vs. 18.6 ± 10.5 days, p = 0.019. Early ligation of medical refractory PDA in very-low-birth-weight premature infants improves enteral feeding tolerance and reduces TPN and ventilator use, but long-term benefits need further investigation.

  7. Experience with rubber band ligation of hemorrhoids in northern ...

    African Journals Online (AJOL)

    Background: Treatment of hemorrhoids in Nigeria is usually done by the traditional open method that requires hospital admission; anesthesia and is associated with high morbidity. Rubber band ligation is a suitable alternative to open hemorrhoidectomy and has the potential to reduce the need for hospital admission.

  8. A CMOS current-mode operational amplifier

    DEFF Research Database (Denmark)

    Kaulberg, Thomas

    1993-01-01

    current-mode feedback amplifier or a constant bandwidth in a transimpedance feedback amplifier. The amplifier is found to have a gain-bandwidth product of 3 MHz, an offset current of 0.8 μA (signal range ±700 μA), and a (theoretically) unlimited slew rate. The amplifier is realized in a standard CMOS 2......A fully differential-input, differential-output, current-mode operational amplifier (COA) is described. The amplifier utilizes three second-generation current conveyors (CCIIs) as the basic building blocks. It can be configured to provide either a constant gain-bandwidth product in a fully balanced...

  9. Terminalia Chebula provides protection against dual modes of necroptotic and apoptotic cell death upon death receptor ligation.

    Science.gov (United States)

    Lee, Yoonjung; Byun, Hee Sun; Seok, Jeong Ho; Park, Kyeong Ah; Won, Minho; Seo, Wonhyoung; Lee, So-Ra; Kang, Kidong; Sohn, Kyung-Cheol; Lee, Ill Young; Kim, Hyeong-Geug; Son, Chang Gue; Shen, Han-Ming; Hur, Gang Min

    2016-04-27

    Death receptor (DR) ligation elicits two different modes of cell death (necroptosis and apoptosis) depending on the cellular context. By screening a plant extract library from cells undergoing necroptosis or apoptosis, we identified a water extract of Terminalia chebula (WETC) as a novel and potent dual inhibitor of DR-mediated cell death. Investigation of the underlying mechanisms of its anti-necroptotic and anti-apoptotic action revealed that WETC or its constituents (e.g., gallic acid) protected against tumor necrosis factor-induced necroptosis via the suppression of TNF-induced ROS without affecting the upstream signaling events. Surprisingly, WETC also provided protection against DR-mediated apoptosis by inhibition of the caspase cascade. Furthermore, it activated the autophagy pathway via suppression of mTOR. Of the WETC constituents, punicalagin and geraniin appeared to possess the most potent anti-apoptotic and autophagy activation effect. Importantly, blockage of autophagy with pharmacological inhibitors or genetic silencing of Atg5 selectively abolished the anti-apoptotic function of WETC. These results suggest that WETC protects against dual modes of cell death upon DR ligation. Therefore, WETC might serve as a potential treatment for diseases characterized by aberrantly sensitized apoptotic or non-apoptotic signaling cascades.

  10. Modeling of semiconductor optical amplifiers

    DEFF Research Database (Denmark)

    Mørk, Jesper; Bischoff, Svend; Berg, Tommy Winther

    We discuss the modelling of semiconductor optical amplifiers with emphasis on their high-speed properties. Applications in linear amplification as well as ultrafast optical signal processing are reviewed. Finally, the possible role of quantum-dot based optical amplifiers is discussed.......We discuss the modelling of semiconductor optical amplifiers with emphasis on their high-speed properties. Applications in linear amplification as well as ultrafast optical signal processing are reviewed. Finally, the possible role of quantum-dot based optical amplifiers is discussed....

  11. Gingival response in orthodontic patients: Comparative study between self-ligating and conventional brackets.

    Science.gov (United States)

    Folco, Alejandra A; Benítez-Rogé, Sandra C; Iglesias, Marina; Calabrese, Diana; Pelizardi, Cristina; Rosa, Alcira; Brusca, Marisa I; Hecht, Pedro; Mateu, María E

    2014-01-01

    Orthodontic brackets contribute to the accumulation of bacterial plaque on tooth surfaces because they hinder oral hygiene. In contrast to conventional brackets, self-ligating brackets do not require additional parts to support the arches, thus improving dental hygiene. The aim of this study was to compare the gingival response in orthodontic patients wearing self-ligating or conventional brackets. A sample of 22 patients aged 16 to 30 years was divided into two groups: Group A, treated with selfligating brackets (Damon system) and Group B, treated with conventional brackets (Roth technique). The following were assessed during the treatment: Plaque Index (PI), Gingival Index (GI) and Probing Depth (PD), and sub-gingival samples were taken from teeth 14/24 for microbiological observation. No statistically significant difference was found between Groups A and B; p>0.05 (sign-ranked) or between PI, GI and PD at the different times (Friedman's Analysis of Variance), even though the indices were found to increase at 14 days, particularly for self-ligating brackets. The quantity and quality of microorganisms present were compatible with health on days 0, 28 and 56. As from day 14 there is a predominance of microbiota compatible with gingivitis in both groups. In the samples studied, orthodontic treatment increases bacterial plaque and inflammatory gingival response, but gingival-periodontal health can be maintained with adequate basic therapy. Self-ligating and conventional brackets produced similar gingival response.

  12. NASA developments in solid state power amplifiers

    Science.gov (United States)

    Leonard, Regis F.

    1990-01-01

    Over the last ten years, NASA has undertaken an extensive program aimed at development of solid state power amplifiers for space applications. Historically, the program may be divided into three phases. The first efforts were carried out in support of the advanced communications technology satellite (ACTS) program, which is developing an experimental version of a Ka-band commercial communications system. These first amplifiers attempted to use hybrid technology. The second phase was still targeted at ACTS frequencies, but concentrated on monolithic implementations, while the current, third phase, is a monolithic effort that focusses on frequencies appropriate for other NASA programs and stresses amplifier efficiency. The topics covered include: (1) 20 GHz hybrid amplifiers; (2) 20 GHz monolithic MESFET power amplifiers; (3) Texas Instruments' (TI) 20 GHz variable power amplifier; (4) TI 20 GHz high power amplifier; (5) high efficiency monolithic power amplifiers; (6) GHz high efficiency variable power amplifier; (7) TI 32 GHz monolithic power amplifier performance; (8) design goals for Hughes' 32 GHz variable power amplifier; and (9) performance goals for Hughes' pseudomorphic 60 GHz power amplifier.

  13. HIGH AVERAGE POWER OPTICAL FEL AMPLIFIERS

    International Nuclear Information System (INIS)

    2005-01-01

    Historically, the first demonstration of the optical FEL was in an amplifier configuration at Stanford University [l]. There were other notable instances of amplifying a seed laser, such as the LLNL PALADIN amplifier [2] and the BNL ATF High-Gain Harmonic Generation FEL [3]. However, for the most part FELs are operated as oscillators or self amplified spontaneous emission devices. Yet, in wavelength regimes where a conventional laser seed can be used, the FEL can be used as an amplifier. One promising application is for very high average power generation, for instance FEL's with average power of 100 kW or more. The high electron beam power, high brightness and high efficiency that can be achieved with photoinjectors and superconducting Energy Recovery Linacs (ERL) combine well with the high-gain FEL amplifier to produce unprecedented average power FELs. This combination has a number of advantages. In particular, we show that for a given FEL power, an FEL amplifier can introduce lower energy spread in the beam as compared to a traditional oscillator. This properly gives the ERL based FEL amplifier a great wall-plug to optical power efficiency advantage. The optics for an amplifier is simple and compact. In addition to the general features of the high average power FEL amplifier, we will look at a 100 kW class FEL amplifier is being designed to operate on the 0.5 ampere Energy Recovery Linac which is under construction at Brookhaven National Laboratory's Collider-Accelerator Department

  14. Electrospun amplified fiber optics.

    Science.gov (United States)

    Morello, Giovanni; Camposeo, Andrea; Moffa, Maria; Pisignano, Dario

    2015-03-11

    All-optical signal processing is the focus of much research aiming to obtain effective alternatives to existing data transmission platforms. Amplification of light in fiber optics, such as in Erbium-doped fiber amplifiers, is especially important for efficient signal transmission. However, the complex fabrication methods involving high-temperature processes performed in a highly pure environment slow the fabrication process and make amplified components expensive with respect to an ideal, high-throughput, room temperature production. Here, we report on near-infrared polymer fiber amplifiers working over a band of ∼20 nm. The fibers are cheap, spun with a process entirely carried out at room temperature, and shown to have amplified spontaneous emission with good gain coefficients and low levels of optical losses (a few cm(-1)). The amplification process is favored by high fiber quality and low self-absorption. The found performance metrics appear to be suitable for short-distance operations, and the large variety of commercially available doping dyes might allow for effective multiwavelength operations by electrospun amplified fiber optics.

  15. Size-amplified acoustofluidic separation of circulating tumor cells with removable microbeads

    Science.gov (United States)

    Liu, Huiqin; Ao, Zheng; Cai, Bo; Shu, Xi; Chen, Keke; Rao, Lang; Luo, Changliang; Wang, Fu-Bin; Liu, Wei; Bondesson, Maria; Guo, Shishang; Guo, Feng

    2018-06-01

    Isolation and analysis of rare circulating tumor cells (CTCs) is of great interest in cancer diagnosis, prognosis, and treatment efficacy evaluation. Acoustofluidic cell separation becomes an attractive method due to its contactless, noninvasive, simple, and versatile features. However, the indistinctive physical difference between CTCs and normal blood cells limits the purity of CTCs using current acoustic methods. Herein, we demonstrate a size-amplified acoustic separation and release of CTCs with removable microbeads. CTCs selectively bound to size-amplifiers (40 μm-diameter anti-EpCAM/gelatin-coated SiO2 microbeads) have significant physical differences (size and mechanics) compared to normal blood cells, resulting in an amplification of acoustic radiation force approximately a hundredfold over that of bare CTCs or normal blood cells. Therefore, CTCs can be efficiently sorted out with size-amplifiers in a traveling surface acoustic wave microfluidic device and released from size-amplifiers by enzymatic degradation for further purification or downstream analysis. We demonstrate a cell separation from blood samples with a total efficiency (E total) of ∼ 77%, purity (P) of ∼ 96%, and viability (V) of ∼83% after releasing cells from size-amplifiers. Our method substantially improves the emerging application of rare cell purification for translational medicine.

  16. Does the number of veins ligated during varicococele surgery influence post-operative semen and hormone results?

    Science.gov (United States)

    Majzoub, A; Elbardisi, H; Arafa, M; Agarwal, A; Al Said, S; Al Rumaihi, K

    2016-09-01

    Varicocele is a well-established cause of male subfertility, which is directly proportional to its clinical grade. Although newer ultrasonic grading systems have taken into account the existence of pampiniform venous plexi, little is known about the clinical significance of the number of veins ligated during surgery. Very few undersized studies reported an influence which triggered the need to evaluate such association. This is a retrospective study of 378 patients who underwent left microsurgical subinguinal varicocoelectomy. Semen analyses and blood hormone studies performed pre-operatively were compared to those executed 6 months after surgery. Patients were divided into abnormal semen and normal semen groups based on their initial semen results. They were also subdivided according to the number of veins ligated intraoperatively into three groups: 10 veins. Sperm count, total motility, and progressive motility were significantly increased in 62, 60.3, and 53.3% of patients post-operatively (p = 0.001), respectively. No significant differences in hormone levels were detected overall. Of the 378 patients, 332 had an abnormal semen analysis, while the remaining 46 patients had a normal result. Sperm count, total motility, and progressive motility significantly increased after varicocoelectomy in patients with an abnormal initial semen analysis (p = 0.001). In 48.7% of patients, 5-10 veins were ligated during surgery, whereas 28.3% had >10 and 23% had <5 ligated veins. No statistically significant differences were noted in the initial or the follow-up results among the number of vein subgroups. Varicocele ligation improves patients' fertility potential. This improvement, however, is not influenced by the number of veins ligated intraoperatively. Clinical grading maintains its superiority in the evaluation of varicocele patients. © 2016 American Society of Andrology and European Academy of Andrology.

  17. Oesophageal variceal band ligation using a Saeed Six-Shooter ...

    African Journals Online (AJOL)

    Background: Oesophageal varices are common sequelae of cirrhosis, which when they bleed can be difficult to control. Oesophageal variceal band ligation, being the best modality for controlling variceal bleeding has not been common practice in West Africa, a region recognized to have a high prevalence of liver diseases.

  18. Fast pulse amplifier

    International Nuclear Information System (INIS)

    Lepetit, J.; Poussier, E.

    1984-01-01

    This amplifier comprises an inverter transformer, the primary circuit of which receives a pulse and the secondary circuit of which is connected to several amplifying elements in parallel. The inverter transformer is made of coaxial cable segments winded around a magnetic torus; the cable cores connected in series constitute the primary circuit and the braiding of cables, connected in parallel, are the secondary circuit. The transformer comprises, besides, delay lines in series with each braiding of the secondary circuit, these ones are such that pulses issued from each braiding arrive together to the secondary circuit connectors. This invention applies, noticeably in the case of a high voltage amplifier, to the control of deflection blocks of particles used in medicine or in particle accelerators [fr

  19. A fluidic/pneumatic interface amplifier

    Science.gov (United States)

    Limbert, D. E.; Kegel, T. M.

    The development of a low cost, reliable, linear pressure amplifier to interface Laminar Proportional Amplifiers (LPA) to pneumatic controllers is presented. The amplifier consists of an LPA input stage and an output stage consisting of a venturi in series with a bellows nozzle valve. The LPA output drives the bellows nozzle valve thereby altering the flowrate through the venturi. The pressure within the venturi throat region, which is the amplifier output, changes with the flowrate. Non-linear characteristics, due to supersonic flow within the venturi, are altered through the use of feedback to the LPA input. A computer based model, to aid in optimizing the amplifier design, is developed. This model incorporates the effects of shock waves and boundary layers within the venturi. Good correspondence between the model and an experimental prototype is shown.

  20. Assembly of a biocompatible triazole-linked gene by one-pot click-DNA ligation

    Science.gov (United States)

    Kukwikila, Mikiembo; Gale, Nittaya; El-Sagheer, Afaf H.; Brown, Tom; Tavassoli, Ali

    2017-11-01

    The chemical synthesis of oligonucleotides and their enzyme-mediated assembly into genes and genomes has significantly advanced multiple scientific disciplines. However, these approaches are not without their shortcomings; enzymatic amplification and ligation of oligonucleotides into genes and genomes makes automation challenging, and site-specific incorporation of epigenetic information and/or modified bases into large constructs is not feasible. Here we present a fully chemical one-pot method for the assembly of oligonucleotides into a gene by click-DNA ligation. We synthesize the 335 base-pair gene that encodes the green fluorescent protein iLOV from ten functionalized oligonucleotides that contain 5ʹ-azide and 3ʹ-alkyne units. The resulting click-linked iLOV gene contains eight triazoles at the sites of chemical ligation, and yet is fully biocompatible; it is replicated by DNA polymerases in vitro and encodes a functional iLOV protein in Escherichia coli. We demonstrate the power and potential of our one-pot gene-assembly method by preparing an epigenetically modified variant of the iLOV gene.

  1. Amplifier for nuclear spectrometry

    International Nuclear Information System (INIS)

    Suarez Canner, E.

    1996-01-01

    The spectroscopy amplifier model AE-020 is designed to adjust suitable the pulses coming from nuclear radiation detectors. Due to is capacity and specifications, the amplifier can be used together with high and medium resolution spectroscopy system

  2. Evaluation of genetic diversity in Chinese kale (Brassica oleracea L. var. alboglabra Bailey) by using rapid amplified polymorphic DNA and sequence-related amplified polymorphism markers.

    Science.gov (United States)

    Zhang, J; Zhang, L G

    2014-02-14

    Chinese kale is an original Chinese vegetable of the Cruciferae family. To select suitable parents for hybrid breeding, we thoroughly analyzed the genetic diversity of Chinese kale. Random amplified polymorphic DNA (RAPD) and sequence-related amplified polymorphism (SRAP) molecular markers were used to evaluate the genetic diversity across 21 Chinese kale accessions from AVRDC and Guangzhou in China. A total of 104 bands were detected by 11 RAPD primers, of which 66 (63.5%) were polymorphic, and 229 polymorphic bands (68.4%) were observed in 335 bands amplified by 17 SRAP primer combinations. The dendrogram showed the grouping of the 21 accessions into 4 main clusters based on RAPD data, and into 6 clusters based on SRAP and combined data (RAPD + SRAP). The clustering of accessions based on SRAP data was consistent with petal colors. The Mantel test indicated a poor fit for the RAPD and SRAP data (r = 0.16). These results have an important implication for Chinese kale germplasm characterization and improvement.

  3. Modeling FWM and impairments aware amplifiers placement technique for an optical MAN/WAN: Inline amplifiers case

    Science.gov (United States)

    Singh, Gurpreet; Singh, Maninder Lal

    2015-08-01

    A new four wave mixing (FWM) model for an optical network with amplifiers and a comparative analysis among three proposed amplifiers placement techniques have been presented in this paper. The FWM model is validated with the experimental measured data. The novelty of this model is its uniqueness that on direct substitutions of network parameters like length, it works even for unequal inter amplifier separations. The novelty of the analysis done among three schemes is that it presents fair choice of amplifiers placement methods for varied total system length. The appropriateness of these three schemes has been analyzed on the basis of critical system length, critical number of amplifiers and critical bit error rate (10-9) in presence of four wave mixing (FWM) and amplified spontaneous emission noise (ASE). The implementation of analysis done has been given with the help of an example of a regenerative metropolitan area network (MAN). The results suggest that the decreasing fiber section scheme should be avoided for placements of amplifiers and schemes IUFS and EFS shows their importance interchangeably for different set of parameters.

  4. Label-free genotyping of cytochrome P450 2D6*10 using ligation-mediated strand displacement amplification with DNAzyme-based chemiluminescence detection.

    Science.gov (United States)

    Wang, Hong-Qi; Wu, Zhan; Zhang, Yan; Tang, Li-Juan; Yu, Ru-Qin; Jiang, Jian-Hui

    2012-01-13

    Genotyping of cytochrome P450 monooxygenase 2D6*10 (CYP2D6*10) plays an important role in pharmacogenomics, especially in clinical drug therapy of Asian populations. This work reported a novel label-free technique for genotyping of CYP2D6*10 based on ligation-mediated strand displacement amplification (SDA) with DNAzyme-based chemiluminescence detection. Discrimination of single-base mismatch is firstly accomplished using DNA ligase to generate a ligation product. The ligated product then initiates a SDA reaction to produce aptamer sequences against hemin, which can be probed by chemiluminescence detection. The proposed strategy is used for the assay of CYP2D6*10 target and the genomic DNA. The results reveal that the proposed technique displays chemiluminescence responses in linear correlation to the concentrations of DNA target within the range from 1 pM to 1 nM. A detection limit of 0.1 pM and a signal-to-background ratio of 57 are achieved. Besides such high sensitivity, the proposed CYP2D6*10 genotyping strategy also offers superb selectivity, great robustness, low cost and simplified operations due to its label-free, homogeneous, and chemiluminescence-based detection format. These advantages suggest this technique may hold considerable potential for clinical CYP2D6*10 genotyping and association studies. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Semiconductor quantum-dot lasers and amplifiers

    DEFF Research Database (Denmark)

    Hvam, Jørn Märcher; Borri, Paola; Ledentsov, N. N.

    2002-01-01

    -power surface emitting VCSELs. We investigated the ultrafast dynamics of quantum-dot semiconductor optical amplifiers. The dephasing time at room temperature of the ground-state transition in semiconductor quantum dots is around 250 fs in an unbiased amplifier, decreasing to below 50 fs when the amplifier...... is biased to positive net gain. We have further measured gain recovery times in quantum dot amplifiers that are significantly lower than in bulk and quantum-well semiconductor optical amplifiers. This is promising for future demonstration of quantum dot devices with high modulation bandwidth...

  6. NIF/LMJ prototype amplifier mechanical design

    International Nuclear Information System (INIS)

    Horvath, J.

    1996-10-01

    Amplifier prototypes for the National Ignition Facility and the Laser Megajoule will be tested at Lawrence Livermore National Laboratory. The prototype amplifier, which is an ensemble of modules from LLNL and Centre d'Etudes de Limeil-Valenton, is cassette-based with bottom access for maintenance. A sealed maintenance transfer vehicle which moves optical cassettes between the amplifier and the assembly cleanroom, and a vacuum gripper which holds laser slabs during cassette assembly will also be tested. The prototype amplifier will be used to verify amplifier optical performance, thermal recovery time, and cleanliness of mechanical operations

  7. 5 Watt GaN HEMT Power Amplifier for LTE

    Directory of Open Access Journals (Sweden)

    K. Niotaki

    2014-04-01

    Full Text Available This work presents the design and implementation of a stand-alone linear power amplifier at 2.4 GHz with high output power. A GaN HEMT transistor is selected for the design and implementation of the power amplifier. The device exhibits a gain of 11.7 dB and a drain efficiency of 39% for an output power of 36.7 dBm at 2.4 GHz for an input power of 25dBm. The carrier to intermodulation ratio is better than 25 dB for a two tone input signal of 25 dBm of total power and a spacing of 5 MHz. The fabricated device is also tested with LTE input signals of different bandwidths (5MHz to 20MHz.

  8. Endoscopic variceal band ligation: a local experience | Jani | East ...

    African Journals Online (AJOL)

    Objective: To evaluate the results of endoscopic variceal band ligation (EVBL) in the local set-up. Design: Retrospective analysis of data of all patients who had EVBL. Setting: Patients having EVBL at the office endoscopy suite. The Nairobi Hospital, the Aga Khan Hospital and M.P Shah Hospital. Methods: The varices were ...

  9. A low-voltage sense amplifier with two-stage operational amplifier clamping for flash memory

    Science.gov (United States)

    Guo, Jiarong

    2017-04-01

    A low-voltage sense amplifier with reference current generator utilizing two-stage operational amplifier clamp structure for flash memory is presented in this paper, capable of operating with minimum supply voltage at 1 V. A new reference current generation circuit composed of a reference cell and a two-stage operational amplifier clamping the drain pole of the reference cell is used to generate the reference current, which avoids the threshold limitation caused by current mirror transistor in the traditional sense amplifier. A novel reference voltage generation circuit using dummy bit-line structure without pull-down current is also adopted, which not only improves the sense window enhancing read precision but also saves power consumption. The sense amplifier was implemented in a flash realized in 90 nm flash technology. Experimental results show the access time is 14.7 ns with power supply of 1.2 V and slow corner at 125 °C. Project supported by the National Natural Science Fundation of China (No. 61376028).

  10. Clinical and psychological repercussions of videolaparoscopic tubal ligation: observational, single cohort, retrospective study

    Directory of Open Access Journals (Sweden)

    Daniel Spadoto Dias

    Full Text Available CONTEXT AND OBJECTIVE: Tubal ligation is one of the most commonly used contraceptive methods worldwide. Since the controversy over the potential effects of tubal sterilization still continues, this study aimed to evaluate the clinical and psychological repercussions of videolaparoscopic tubal ligation.DESIGN AND SETTING: Observational, single cohort, retrospective study, conducted in a tertiary public hospital.METHODS: A questionnaire was applied to 130 women aged 21-46 years who underwent videolaparoscopic tubal ligation by means of tubal ring insertion or bipolar electrocoagulation and sectioning, between January 1999 and December 2007. Menstrual cycle interval, intensity and duration of bleeding, premenstrual symptoms, dysmenorrhea, dyspareunia, noncyclic pelvic pain and degree of sexual satisfaction were assessed in this questionnaire. Each woman served as her own control, and comparisons were made between before and after the surgical procedure and between the two techniques used.RESULTS: The clinical and psychological repercussions were significant, with increases in bleeding (P = 0.001, premenstrual symptoms (P < 0.001, dysmenorrhea (P = 0.019 and noncyclic pelvic pain (P = 0.001; and reductions in the number of sexual intercourse occurrences per week (P = 0.001 and in libido (P = 0.001. Women aged ≤ 35 years at the time of sterilization were more likely to develop menstrual abnormalities. The bipolar electrocoagulation method showed greater clinical and psychological repercussions.CONCLUSION: Regardless of the technique used, videolaparoscopic tubal ligation had repercussions consisting of increased menstrual flow and premenstrual symptoms, especially in women aged ≤ 35 years, and also had a negative influence on sexual activity.

  11. Female sterilization by tubal ligation at caesarean section in Makurdi ...

    African Journals Online (AJOL)

    Background: Female sterilization is an important tool in reducing unplanned pregnancy and maternal mortality in our environment. The aim of this study was to determine the incidence, sociodemographic characteristics, technique, effectiveness and complications associated with female sterilization by bilateral tubal ligation ...

  12. Assembly and maintenance of full scale NIF amplifiers in the amplifier module prototype laboratory (AMPLAB)

    International Nuclear Information System (INIS)

    Horvath, J. A.

    1998-01-01

    Mechanical assembly and maintenance of the prototype National Ignition Facility amplifiers in the Amplifier Module Prototype Laboratory (AMPLAB) at Lawrence Livermore National Laboratory requires specialized equipment designed to manipulate large and delicate amplifier components in a safe and clean manner. Observations made during the operation of this assembly and maintenance equipment in AMPLAB provide design guidance for similar tools being built for the National Ignition Facility. Fixtures used for amplifier frame installation, laser slab and flashlamp cassette assembly, transport, and installation, and in-situ blastshield exchange are presented. Examples include a vacuum slab gripper, slab handling clean crane, slab cassette assembly fixture, sealed transport vehicle for slab cassette movement between the cleanroom and amplifier, slab cassette transfer fixture between the cleanroom and transport vehicle, and equipment needed for frame assembly unit, blastshield, an d flashlamp cassette installation and removal. The use of these tools for amplifier assembly, system reconfiguration, reflector replacement, and recovery from an abnormal occurrence such as a flashlamp explosion is described. Observations are made on the design and operation of these tools and their contribution to the final design

  13. Meta-analysis: banding ligation and medical interventions for the prevention of rebleeding from oesophageal varices

    DEFF Research Database (Denmark)

    Thiele, Maja; Krag, A; Rohde, Ulrich

    2012-01-01

    In patients with oesophageal varices, the combination of endoscopic variceal ligation (EVL) and medical therapy is recommended as standard of care for prevention of rebleeding. The results of previous meta-analyses on this topic are equivocal.......In patients with oesophageal varices, the combination of endoscopic variceal ligation (EVL) and medical therapy is recommended as standard of care for prevention of rebleeding. The results of previous meta-analyses on this topic are equivocal....

  14. Management of Fistula‑In‑Ano with Special Reference to Ligation of ...

    African Journals Online (AJOL)

    Department of General Surgery, MKCG Medical College, Berhampur, Odisha, India. ABSTRACT ... Management of fistula‑in‑ano through ligation of intersphincteric fistula tract. 2 ... At the time of admission, a detailed history and the clinical.

  15. Impairment of the organization of locomotor and exploratory behaviors in bile duct-ligated rats

    DEFF Research Database (Denmark)

    Leke, Renata; de Oliveira, Diogo L; Mussulini, Ben Hur M.

    2012-01-01

    Hepatic encephalopathy (HE) arises from acute or chronic liver diseases and leads to several problems, including motor impairment. Animal models of chronic liver disease have extensively investigated the mechanisms of this disease. Impairment of locomotor activity has been described in different...... female Wistar rats underwent common bile duct ligation (BDL rats) or the manipulation of common bile duct without ligation (control rats). Six weeks after surgery, control and BDL rats underwent open-field, plus-maze and foot-fault behavioral tasks. The BDL rats developed chronic liver failure...

  16. Behavioral modeling of microwave power amplifiers using a look up table method

    NARCIS (Netherlands)

    Shen, Y.; Gajadharsing, J.; Tauritz, J.L.

    2007-01-01

    The possibility of building a microwave power amplifier (PA) behavioral model based on the look-up table principle is investigated. The model so constructed avoids the difficulties in model structure selection and/or its parameter estimation.

  17. Evaluation of low ligation and high proceedings of varicocele

    International Nuclear Information System (INIS)

    Khan, M.; Khan, S.; Pervez, A.; Nawaz, H.; Ahmed, S.; Tareen, S.

    2003-01-01

    Objective: To describe the mode of presentation of varicocele and to compare the low ligation (Inguinal approach/ ivanissevich s procedure) and high ligation (Retroperitoneal approach/modified Palomo's procedure) of varicocele repair regarding efficacy and postoperative complications. Subjects and Methods: A total of 213 patients of varicocele who underwent treatment in the department and completed 6 months follow-up were included in the study. The mode of presentation of varicocele was recorded for all patients. For treatment purpose patients were randomly divided into two groups: in group I (n:115) varicocele was ligated by inguinal approach (Ivanissevich s procedure) while in group II (n: 98) by retroopertional approach (modified Palomo s procedure). The efficacy and postoperative complications of the two procedures were carefully recorded and compared between the two groups. Results: The mean age of the patients of group-I and group-II was 27.2 and 27.5 years respectively. More than 50% patients of both groups presented with feeling of heaviness/ dragging sensation on ipsilateral side. Presentation with infertility/sub fertility in group-I and group-II was 16.5% and 15.3% respectively. Majority of patients of both groups had grade III varicocele with visible deformity. The rate of postoperative complications was very low in both groups of patients. Recurrence of varicocele and postoperative hydrocele formation were slightly more common in group-II as compared to group-I but the difference was statistically not significant (p>0.05). An extremely significant improvement occurred postoperatively in both sperms density and motility in infertile/sub fertile patients of both groups. Conclusion: Both procedures of varicocele repair are equally equally effective and have a low rate of complications. There is no significant difference in postoperatively complications. An extremely significant improvement occurs in semen parameters of infertile/sub fertile patients

  18. A new screening method for selection of desired recombinant ...

    African Journals Online (AJOL)

    A new screening method for selection of desired recombinant plasmids in molecular cloning. ... African Journal of Biotechnology ... Regarding the facts of this study, after digestion process, the products directly were subjected to ligation. Due to ...

  19. European Research on THz Vacuum Amplifiers

    DEFF Research Database (Denmark)

    Brunetti, F.; Cojocarua, C.-S.; de Rossi, A.

    2010-01-01

    The OPTHER (OPtically Driven TeraHertz AmplifiERs) project represents a considerable advancement in the field of high frequency amplification. The design and realization of a THz amplifier within this project is a consolidation of efforts at the international level from the main players...... of the European research, academy and industry in vacuum electronics. This paper describes the status of the project and progress towards the THz amplifier realization....

  20. Integrated amplifying circuit with MOS transistors

    Energy Technology Data Exchange (ETDEWEB)

    Baylac, B; Merckel, G; Meunier, P

    1974-01-25

    The invention relates to a feedback-pass-band amplifier with MOS-transistors. The differential stage of conventional amplifiers is changed into an adding state, whereas the differential amplification stages are changed into amplifier inverter stages. All MOS transistors used in that amplifier are of similar configuration and are interdigitized, whereby the operating speed dispersion is reduced. This can be applied to obtaining a measurement channel for proportional chambers.

  1. Ligation of major histocompatibility complex class I antigens (MHC-I) prevents apoptosis induced by Fas or SAPK/JNK activation in T-lymphoma cells

    DEFF Research Database (Denmark)

    Lamberth, K; Claesson, M H

    2001-01-01

    Early apoptosis in Jurkat T-lymphoma cells was induced by agonistic anti-Fas Ab or by anisomycin which activates the stress kinases SAPK/JNK. Apoptosis was inhibited by ligation of major histocompatibility complex class I antigens (MHC-I). MHC-I ligation induced upregulation of the anti-apoptotic......Early apoptosis in Jurkat T-lymphoma cells was induced by agonistic anti-Fas Ab or by anisomycin which activates the stress kinases SAPK/JNK. Apoptosis was inhibited by ligation of major histocompatibility complex class I antigens (MHC-I). MHC-I ligation induced upregulation of the anti......-apoptotic Bcl-2 protein and stabilized the mitochondrial membrane potential (Deltapsim). MHC-I ligation also prevented downregulation of Bcl-2 and destabilization of Deltapsim induced by anti-Fas Ab treatment or anisomycin exposure. Studies on three different Jurkat cell mutants deficient for src p56(lck), ZAP......-70 kinase, or TCR/CD3 gamma-chain showed that the cells undergo apoptosis after Fas ligation. Anisomycin exposure induced apoptosis in the src p56(lck)-deficient cell line but not in the two other mutant cell lines. Simultaneous cross-linking of MHC-I and Fas ligation inhibited apoptosis in the ZAP...

  2. External root resorption with the self-ligating Damon system—a retrospective study

    Directory of Open Access Journals (Sweden)

    Roberta Heiffig Handem

    2016-07-01

    Full Text Available Abstract Background The aim of this study was to compare the degree of external apical root resorption (EARR in patients treated with self-ligating Damon appliances and with conventional preadjusted appliances. Methods The sample comprised 52 patients, divided into two groups. Group 1 consisted of 25 patients treated with self-ligating Damon appliances, with an initial age of 16.04 years, final age of 18.06 years, and treatment time of 2.02 years. Group 2 consisted of 27 patients, treated with conventional preadjusted appliances, with an initial age of 16.77 years, final age of 18.47 years and treatment time of 1.70 years. The groups were matched regarding the initial and final ages, treatment time, type of malocclusion, and treatment protocol without extractions. Root resorption was evaluated on periapical radiographs of the maxillary and mandibular incisors at the end of orthodontic treatment with the scores of Levander and Malmgren. Intergroup comparisons of root resorption were performed with Mann-Whitney tests. Results No significant difference in the degree of root resorption between the two groups was found. Conclusions Similar degrees of resorption can be expected after non-extraction treatment with Damon self-ligating or conventional preadjusted appliances.

  3. External root resorption with the self-ligating Damon system-a retrospective study.

    Science.gov (United States)

    Handem, Roberta Heiffig; Janson, Guilherme; Matias, Murilo; de Freitas, Karina Maria Salvatore; de Lima, Darwin Vaz; Garib, Daniela Gamba; de Freitas, Marcos Roberto

    2016-12-01

    The aim of this study was to compare the degree of external apical root resorption (EARR) in patients treated with self-ligating Damon appliances and with conventional preadjusted appliances. The sample comprised 52 patients, divided into two groups. Group 1 consisted of 25 patients treated with self-ligating Damon appliances, with an initial age of 16.04 years, final age of 18.06 years, and treatment time of 2.02 years. Group 2 consisted of 27 patients, treated with conventional preadjusted appliances, with an initial age of 16.77 years, final age of 18.47 years and treatment time of 1.70 years. The groups were matched regarding the initial and final ages, treatment time, type of malocclusion, and treatment protocol without extractions. Root resorption was evaluated on periapical radiographs of the maxillary and mandibular incisors at the end of orthodontic treatment with the scores of Levander and Malmgren. Intergroup comparisons of root resorption were performed with Mann-Whitney tests. No significant difference in the degree of root resorption between the two groups was found. Similar degrees of resorption can be expected after non-extraction treatment with Damon self-ligating or conventional preadjusted appliances.

  4. Comparative Study of Si and SiC MOSFETs for High Voltage Class D Audio Amplifiers

    DEFF Research Database (Denmark)

    Nielsen, Dennis; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    Silicon (Si) Metal-Oxide-Semiconductor Field-Effect Transistors (MOSFETs) are traditional utilised in class D audio amplifiers. It has been proposed to replace the traditional inefficient electrodynamic transducer with the electrostatic transducer. This imposes new high voltage requirements...... on the MOSFETs of class D amplifiers, and significantly reduces the selection of suitable MOSFETs. As a consequence it is investigated, if Silicon-Carbide (SiC) MOSFETs could represent a valid alternative. The theory of pulse timing errors are revisited for the application of high voltage and capactive loaded...... class D amplifiers. It is shown, that SiC MOSFETs can compete with Si MSOFETs in terms of THD. Validation is done using simulations and a 500 V amplifier driving a 100 nF load. THD+N below 0.3 % is reported...

  5. Multiplexed homogeneous proximity ligation assays for high throughput protein biomarker research in serological material

    DEFF Research Database (Denmark)

    Lundberg, Martin; Thorsen, Stine Buch; Assarsson, Erika

    2011-01-01

    A high throughput protein biomarker discovery tool has been developed based on multiplexed proximity ligation assays (PLA) in a homogeneous format in the sense of no washing steps. The platform consists of four 24-plex panels profiling 74 putative biomarkers with sub pM sensitivity each consuming...... sequences are united by DNA ligation upon simultaneous target binding forming a PCR amplicon. Multiplex PLA thereby converts multiple target analytes into real-time PCR amplicons that are individually quantificatied using microfluidic high capacity qPCR in nano liter volumes. The assay shows excellent...

  6. Adrenal function in preterm infants undergoing patent ductus arteriosus ligation.

    LENUS (Irish Health Repository)

    El-Khuffash, Afif

    2013-01-01

    Targeted milrinone treatment for low left ventricular output (LVO) reduces the incidence of acute cardiorespiratory instability following ligation of patent ductus arteriosus (PDA) in preterm infants. Despite this, some infants continue to experience postoperative deterioration. Adrenal insufficiency related to prematurity has been postulated as a possible mechanism.

  7. The design of a linear amplifier for very small DC-currents, called LASC

    International Nuclear Information System (INIS)

    Stroem, S.; Storruste, A.

    1989-12-01

    A linear amplifier for the monitoring of very small currents from a high pressure ionization chamber has been designed. In the traditional design of an ionization chamber current amplifier, selected semiconductors and resistors are chosen to measure the very small currents in question. As the leakage currents in these semiconductors are larger than the smallest currents to be measured, very sophisticated electronics must be employed to succeed with the design. In order to overcome this disadvantage, the reported design is based on the following basic features: A capacitor is charged by the chamber ion current during a fixed time period, without loading the amplifier input. The use of a peak detector makes bouncing of the time-lag relay contacts unimportant, and allows an analog-to-digital converter to store the voltage build-up in the capacitor as a digital value. The measuring range of the amplifier, 0.001 pA to 1000 pA, makes it suitable for measuring gamma radiation in the air, both under normal and abnormal conditions. The design of the amplifier is described and results from tests are presented. 6 refs.; 6 figs.; 3 tabs

  8. Compliance with Papanicolaou smear screening following tubal ligation in women with cervical cancer.

    Science.gov (United States)

    Winkler, H A; Anderson, P S; Fields, A L; Runowicz, C D; DeVictoria, C; Goldberg, G L

    1999-01-01

    To evaluate patient compliance with Papanicolaou (Pap) smear screening after tubal ligation compared with other methods of birth control in patients who develop cervical cancer, a retrospective review of 262 women with cervical cancer diagnosed at age Albert Einstein College of Medicine from January 1987 to December 1995. Demographic data, stage of the disease, histologic type, history of smoking, history of sexually transmitted disease (STD), and birth control use were recorded. The Pap screening history was obtained from all the patients. Women who had a bilateral tubal ligation (BTL) were compared with those who did not have this form of birth control. The date and result of their last Pap test prior to their diagnosis of cervical cancer was noted. Two hundred fourteen women with cervical cancer were evaluable. The clinical stage, mean age, history of smoking, and history of STD were similar for both groups. Gravidity among the BTL group was higher than in the non-BTL group (p < 0.01). Forty-eight (22.4%) women had a previous BTL. Twenty-seven of these 48 patients (56.3%) did not have a Pap smear within 3 years prior to the diagnosis of cervical cancer. Of the 166 patients, 61 (36.7%) did not have a Pap test within 3 years (p < 0.05). Fourteen women (29.2%) in the tubal ligation group never returned for a Pap test following the BTL. An average of 6.2+/-5.9 years elapsed since the last Pap test in the BTL group, with 4.0+/-5.1 years in the nontubal ligation group (p < 0.05). There was a correlation between the number of years since BTL (14.2+/-7.7) to the number of years since the last Pap test (6.2+/-5.9) (p < 0.05). Women who have had a BTL should be considered high risk because of poor screening compliance. A Pap test every 3 years is not adequate in this high-risk population group. We advocate improved counseling regarding the importance of continued annual Pap screening for women who are considering tubal ligation.

  9. Preparation of C-terminally modified chemokines by expressed protein ligation.

    Science.gov (United States)

    Baumann, Lars; Steinhagen, Max; Beck-Sickinger, Annette G

    2013-01-01

    In order to link structural features on a molecular level to the function of chemokines, site-specific modification strategies are strongly required. These can be used to incorporate fluorescent dyes and/or physical probes to allow investigations in a wide range of biological and physical techniques, e.g., nuclear magnetic resonance (NMR) spectroscopy, fluorescence microscopy, fluorescence resonance energy transfer (FRET), or fluorescence correlation spectroscopy (FCS). Only a limited number of functional groups within the 20 canonical amino acids allow ligation strategies that can be helpful to introduce novel functionalities, which in turn expand the scope of chemoselective and orthogonal reactivity of (semi)synthetic chemokines. In the present chapter we mainly focus on the fabulous history of native chemical ligation (NCL) and provide a general protocol for the preparation of C-terminally modified SDF-1α including tips and tricks for practical work. We believe that this protocol can be easily adapted to other chemokines and many proteins in general.

  10. Power Amplifiers in CMOS Technology: A contribution to power amplifier theory and techniques

    NARCIS (Netherlands)

    Acar, M.

    2011-01-01

    In order to meet the demands from the market on cheaper, miniaturized mobile communications devices realization of RF power amplifiers in the mainstream CMOS technology is essential. In general, CMOS Power Amplifiers (PAs) require high voltage to decrease the matching network losses and for high

  11. An enhanced method for sequence walking and paralog mining: TOPO® Vector-Ligation PCR

    Directory of Open Access Journals (Sweden)

    Davis Thomas M

    2010-03-01

    Full Text Available Abstract Background Although technological advances allow for the economical acquisition of whole genome sequences, many organisms' genomes remain unsequenced, and fully sequenced genomes may contain gaps. Researchers reliant upon partial genomic or heterologous sequence information require methods for obtaining unknown sequences from loci of interest. Various PCR based techniques are available for sequence walking - i.e., the acquisition of unknown DNA sequence adjacent to known sequence. Many such methods require rigid, elaborate protocols and/or impose narrowly confined options in the choice of restriction enzymes for necessary genomic digests. We describe a new method, TOPO® Vector-Ligation PCR (or TVL-PCR that innovatively integrates available tools and familiar concepts to offer advantages as a means of both targeted sequence walking and paralog mining. Findings TVL-PCR exploits the ligation efficiency of the pCR®4-TOPO® (Invitrogen, Carlsbad, California vector system to capture fragments of unknown sequence by creating chimeric molecules containing defined priming sites at both ends. Initially, restriction enzyme-digested genomic DNA is end-repaired to create 3' adenosine overhangs and is then ligated to pCR4-TOPO vectors. The ligation product pool is used directly as a template for nested PCR, using specific primers to target orthologous sequences, or degenerate primers to enable capture of paralogous gene family members. We demonstrated the efficacy of this method by capturing entire coding and partial promoter sequences of several strawberry Superman-like genes. Conclusions TVL-PCR is a convenient and efficient method for DNA sequence walking and paralog mining that is applicable to any organism for which relevant DNA sequence is available as a basis for primer design.

  12. Localization of the cochlear amplifier in living sensitive ears.

    Directory of Open Access Journals (Sweden)

    Tianying Ren

    Full Text Available BACKGROUND: To detect soft sounds, the mammalian cochlea increases its sensitivity by amplifying incoming sounds up to one thousand times. Although the cochlear amplifier is thought to be a local cellular process at an area basal to the response peak on the spiral basilar membrane, its location has not been demonstrated experimentally. METHODOLOGY AND PRINCIPAL FINDINGS: Using a sensitive laser interferometer to measure sub-nanometer vibrations at two locations along the basilar membrane in sensitive gerbil cochleae, here we show that the cochlea can boost soft sound-induced vibrations as much as 50 dB/mm at an area proximal to the response peak on the basilar membrane. The observed amplification works maximally at low sound levels and at frequencies immediately below the peak-response frequency of the measured apical location. The amplification decreases more than 65 dB/mm as sound levels increases. CONCLUSIONS AND SIGNIFICANCE: We conclude that the cochlea amplifier resides at a small longitudinal region basal to the response peak in the sensitive cochlea. These data provides critical information for advancing our knowledge on cochlear mechanisms responsible for the remarkable hearing sensitivity, frequency selectivity and dynamic range.

  13. Transmission characteristics of acoustic amplifier in thermoacoustic engine

    International Nuclear Information System (INIS)

    Sun Daming; Qiu Limin; Wang Bo; Xiao Yong

    2008-01-01

    Thermoacoustic engines are promising in practical applications for the merits of simple configuration, reliable operation and environmentally friendly working gas. An acoustic amplifier can increase the output pressure amplitude of a thermoacoustic engine (TE) and improve the matching between the engine and its load. In order to make full use of an acoustic amplifier, the transmission characteristics are studied based on linear thermoacoustic theory. Computational and experimental results show that the amplifying ability of an acoustic amplifier is mainly determined by its geometry parameters and output resistance impedance. The amplifying ability of an acoustic amplifier with appropriate length and diameter reaches its maximum when the output resistance impedance is infinite. It is also shown that the acoustic amplifier consumes an amount of acoustic power when amplifying pressure amplitude and the acoustic power consumption increases with amplifying ratio. Furthermore, a novel cascade acoustic amplifier is proposed, which has a much stronger amplifying ability with reduced acoustic power consumption. In experiments, a two-stage cascade acoustic amplifier amplifies the pressure ratio from 1.177 to 1.62 and produces a pressure amplitude of 0.547 MPa with nitrogen of 2.20 MPa as working gas. Good agreements are obtained between the theoretical analysis and experimental results. This research is instructive for comprehensively understanding the mechanism and making full use of the acoustic amplifier

  14. Distribution of extracellular potassium and electrophysiologic changes during two-stage coronary ligation in the isolated, perfused canine heart

    NARCIS (Netherlands)

    Coronel, R.; Fiolet, J. W.; Wilms-Schopman, J. G.; Opthof, T.; Schaapherder, A. F.; Janse, M. J.

    1989-01-01

    We studied the relation between [K+]o and the electrophysiologic changes during a "Harris two-stage ligation," which is an occlusion of a coronary artery, preceded by a 30-minute period of 50% reduction of flow through the artery. This two-stage ligation has been reported to be antiarrhythmic. Local

  15. Hepatic extraction of the aminoterminal propeptide of type III procollagen before and after bile duct ligation in pigs

    DEFF Research Database (Denmark)

    Bentsen, K D; Henriksen, Jens Henrik Sahl; Boesby, S

    1991-01-01

    before and during a 4-h period after ligation of the common bile duct was assessed from serum PIIINP concentrations in a systemic artery, the portal vein and a hepatic vein of seven healthy anaesthetized pigs. Seven sham-operated anaesthetized pigs served as controls. Ligation of the bile duct did...

  16. Bacterial adhesion on conventional and self-ligating metallic brackets after surface treatment with plasma-polymerized hexamethyldisiloxane.

    Science.gov (United States)

    Tupinambá, Rogerio Amaral; Claro, Cristiane Aparecida de Assis; Pereira, Cristiane Aparecida; Nobrega, Celestino José Prudente; Claro, Ana Paula Rosifini Alves

    2017-01-01

    Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic brackets using the Plasma-Enhanced Chemical Vapor Deposition (PECVD) radio frequency technique. The samples were divided into two groups according to the kind of bracket and two subgroups after surface treatment. Scanning Electron Microscopy (SEM) analysis was performed to assess the presence of bacterial adhesion over samples surfaces (slot and wings region) and film layer integrity. Surface roughness was assessed by Confocal Interferometry (CI) and surface wettability, by goniometry. For bacterial adhesion analysis, samples were exposed for 72 hours to a Streptococcus mutans solution for biofilm formation. The values obtained for surface roughness were analyzed using the Mann-Whitney test while biofilm adhesion were assessed by Kruskal-Wallis and SNK test. Significant statistical differences (pbrackets after surface treatment and between conventional and self-ligating brackets; no significant statistical differences were observed between self-ligating groups (p> 0.05). Plasma-polymerized film deposition was only effective on reducing surface roughness and bacterial adhesion in conventional brackets. It was also noted that conventional brackets showed lower biofilm adhesion than self-ligating brackets despite the absence of film.

  17. Investigation into the effects of stainless steel ligature ties on the mechanical characteristics of conventional and self-ligated brackets subjected to torque.

    Science.gov (United States)

    Al Fakir, Hussam; Carey, Jason P; Melenka, Garrett W; Nobes, David S; Heo, Giseon; Major, Paul W

    2014-09-01

    Torque is applied to orthodontic brackets in order to alter the buccal-lingual angulation of a tooth. One factor that can affect torque is the ligation mode used to retain the archwire in the bracket slot. The objective of this study was to investigate the effects of stainless steel ligation on torque expression and bracket deformation. This study utilized 60 upper right central incisor Damon Q brackets and 60 Ormco Orthos Twin brackets. The brackets used in this study were subdivided into four groups: (1) Damon Q ligated with SS ligature; (2) Damon Q with the sliding bracket door; (3) Orthos Twin bracket ligated with SS wire; and (4) Orthos Twin ligated with elastic ties. All brackets were tested using an orthodontic torque simulating device that applied archwire rotation from 0° to 45°. All brackets ligated with stainless steel ties exhibited greater torque expression and less deformation than brackets without stainless steel ties. As well, Damon Q brackets exhibit less bracket deformation than Orthos Twin brackets. Stainless steel ties can reduce the amount of plastic deformation for both types of brackets used in this study. © 2014 British Orthodontic Society.

  18. A High-Linearity Low-Noise Amplifier with Variable Bandwidth for Neural Recoding Systems

    Science.gov (United States)

    Yoshida, Takeshi; Sueishi, Katsuya; Iwata, Atsushi; Matsushita, Kojiro; Hirata, Masayuki; Suzuki, Takafumi

    2011-04-01

    This paper describes a low-noise amplifier with multiple adjustable parameters for neural recording applications. An adjustable pseudo-resistor implemented by cascade metal-oxide-silicon field-effect transistors (MOSFETs) is proposed to achieve low-signal distortion and wide variable bandwidth range. The amplifier has been implemented in 0.18 µm standard complementary metal-oxide-semiconductor (CMOS) process and occupies 0.09 mm2 on chip. The amplifier achieved a selectable voltage gain of 28 and 40 dB, variable bandwidth from 0.04 to 2.6 Hz, total harmonic distortion (THD) of 0.2% with 200 mV output swing, input referred noise of 2.5 µVrms over 0.1-100 Hz and 18.7 µW power consumption at a supply voltage of 1.8 V.

  19. Superantigen and HLA-DR ligation induce phospholipase-C gamma 1 activation in class II+ T cells

    DEFF Research Database (Denmark)

    Kanner, S B; Odum, Niels; Grosmaire, L

    1992-01-01

    Bacterial enterotoxin superantigens bind directly to HLA class II molecules (HLA-DR) expressed on both APC and activated human T cells, and simultaneously bind to certain V beta chains of the TCR. In this report, we compared early T cell signaling events in human alloantigen-stimulated T cells when...... activated by HLA-DR ligation through antibody cross-linking or by direct enterotoxin superantigen binding. Both types of stimuli induced tyrosine phosphorylation of phosphatidylinositol-specific phospholipase C gamma 1 (PLC gamma 1) and an increase in intracellular calcium concentration; however......, superantigen-induced signaling was stronger than class II ligation alone. Antibody-mediated ligation of HLA-DR with CD3 resulted in augmented PLC gamma 1 activation and increased calcium mobilization, consistent with a mechanism of superantigen activity through a combination of class II and CD3/Ti signals...

  20. Synthesis of water-soluble scaffolds for peptide cyclization, labeling, and ligation

    NARCIS (Netherlands)

    Smeenk, L.E.J.; Dailly, N.; Hiemstra, H.; van Maarseveen, J.H.; Timmerman, P.

    2012-01-01

    The synthesis and applications of water-soluble scaffolds that conformationally constrain side chain unprotected linear peptides containing two cysteines are described. These scaffolds contain a functionality with orthogonal reactivity to be used for labeling and ligation. This is illustrated by the

  1. Bis-ligated Ti and Zr complexes of chelating N-heterocyclic carbenes

    KAUST Repository

    El-Batta, Amer; Waltman, Andrew W.; Grubbs, Robert H.

    2011-01-01

    In this communication we report the synthesis of novel titanium and zirconium complexes ligated by bidentate "salicylaldimine-like" N-heterocyclic carbenes (NHC). Double addition of the NHC chelate to either TiCl4(thf)2 or ZrCl4 forms bis

  2. Testicular reperfusion injury, post ligation of the spermatic cord in ...

    African Journals Online (AJOL)

    This experiment was aimed at investigating the level of tissue regeneration following sanguineous reperfusion post ligation of the spermatic cord in dogs. A total of 5 adult Nigerian local dogs conditioned for 3 weeks, laboratorily evaluated twice weekly prior to surgery were maintained for 1month. Dogs were aseptically ...

  3. Final amplifier design and mercury

    International Nuclear Information System (INIS)

    Rose, E.A.; Hanson, D.E.

    1991-01-01

    The final amplifier for the Mercury KrF excimer facility is being designed. The design exercise involves extensive modeling to predict amplifier performance. Models of the pulsed-power system, including a Child-Langmuir diode with closure, electron-beam energy deposition, KrF laser kinetics, amplified spontaneous emission (ASE), a time-dependent laser extraction in the presence of ASE are presented as a design package. The design exercise indicates that the energy objective of Phase I -- 100 joules -- will be met

  4. Enzyme-linked electrochemical DNA ligation assay using magnetic beads.

    Science.gov (United States)

    Stejskalová, Eva; Horáková, Petra; Vacek, Jan; Bowater, Richard P; Fojta, Miroslav

    2014-07-01

    DNA ligases are essential enzymes in all cells and have been proposed as targets for novel antibiotics. Efficient DNA ligase activity assays are thus required for applications in biomedical research. Here we present an enzyme-linked electrochemical assay based on two terminally tagged probes forming a nicked junction upon hybridization with a template DNA. Nicked DNA bearing a 5' biotin tag is immobilized on the surface of streptavidin-coated magnetic beads, and ligated product is detected via a 3' digoxigenin tag recognized by monoclonal antibody-alkaline phosphatase conjugate. Enzymatic conversion of napht-1-yl phosphate to napht-1-ol enables sensitive detection of the voltammetric signal on a pyrolytic graphite electrode. The technique was tested under optimal conditions and various situations limiting or precluding the ligation reaction (such as DNA substrates lacking 5'-phosphate or containing a base mismatch at the nick junction, or application of incompatible cofactor), and utilized for the analysis of the nick-joining activity of a range of recombinant Escherichia coli DNA ligase constructs. The novel technique provides a fast, versatile, specific, and sensitive electrochemical assay of DNA ligase activity.

  5. A pulse amplifier for nuclear instrumentation

    International Nuclear Information System (INIS)

    Martin, D.; Cliff, P.

    1987-01-01

    A Class-A 1 Watt amplifier has been designed and optimized for nanosecond pulses. Spanning .01MHz to 1300Mhz, signal gain is 26dB with gain flatness of 1dB. The amplifier drive +- 10 volts across 500 with 350ps risetime. Each amplifier is housed in a 2-wide NIM

  6. Simplified Paper Format for Detecting HIV Drug Resistance in Clinical Specimens by Oligonucleotide Ligation

    Science.gov (United States)

    Panpradist, Nuttada; Beck, Ingrid A.; Chung, Michael H.; Kiarie, James N.; Frenkel, Lisa M.; Lutz, Barry R.

    2016-01-01

    Human immunodeficiency virus (HIV) is a chronic infection that can be managed by antiretroviral treatment (ART). However, periods of suboptimal viral suppression during lifelong ART can select for HIV drug resistant (DR) variants. Transmission of drug resistant virus can lessen or abrogate ART efficacy. Therefore, testing of individuals for drug resistance prior to initiation of treatment is recommended to ensure effective ART. Sensitive and inexpensive HIV genotyping methods are needed in low-resource settings where most HIV infections occur. The oligonucleotide ligation assay (OLA) is a sensitive point mutation assay for detection of drug resistance mutations in HIV pol. The current OLA involves four main steps from sample to analysis: (1) lysis and/or nucleic acid extraction, (2) amplification of HIV RNA or DNA, (3) ligation of oligonucleotide probes designed to detect single nucleotide mutations that confer HIV drug resistance, and (4) analysis via oligonucleotide surface capture, denaturation, and detection (CDD). The relative complexity of these steps has limited its adoption in resource-limited laboratories. Here we describe a simplification of the 2.5-hour plate-format CDD to a 45-minute paper-format CDD that eliminates the need for a plate reader. Analysis of mutations at four HIV-1 DR codons (K103N, Y181C, M184V, and G190A) in 26 blood specimens showed a strong correlation of the ratios of mutant signal to total signal between the paper CDD and the plate CDD. The assay described makes the OLA easier to perform in low resource laboratories. PMID:26751207

  7. Evaluation of the force generated by gradual deflection of orthodontic wires in conventional metallic, esthetic, and self-ligating brackets

    Directory of Open Access Journals (Sweden)

    Manoela Fávaro Francisconi

    Full Text Available ABSTRACT Objective: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual increase in wire diameter and deflection and comparing different combinations in the different deflections. Material and Methods: Specimens were set in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342, using the ISO 15841 protocol. Data were subjected to One-way ANOVA, followed by Tukey tests (p<0.05. Results: Self-ligating brackets presented the most similar behavior to each other. For conventional brackets there was no consistent behavior for any of the deflections studied. Conclusions: Self-ligating brackets presented the most consistent and predictable results while conventional brackets, as esthetic brackets, showed very different patterns of forces. Self-ligating brackets showed higher strength in all deflections when compared with the others, in 0.020-inch wires.

  8. Management of anal fistula by ligation of the intersphincteric fistula tract

    DEFF Research Database (Denmark)

    Zirak-Schmidt, Samira; Perdawood, Sharaf

    2014-01-01

    INTRODUCTION: Ligation of the intersphincteric fistula tract (LIFT) is a sphincter-preserving procedure for treatment of anal fistulas described in 2007 by Rojanasakul et al. Several studies have since then assessed the procedure with varied results. This review assesses the relevant literature o...

  9. An Implantable CMOS Amplifier for Nerve Signals

    DEFF Research Database (Denmark)

    Nielsen, Jannik Hammel; Lehmann, Torsten

    2003-01-01

    In this paper, a low noise high gain CMOS amplifier for minute nerve signals is presented. The amplifier is constructed in a fully differential topology to maximize noise rejection. By using a mixture of weak- and strong inversion transistors, optimal noise suppression in the amplifier is achieved....... A continuous-time current-steering offset-compensation technique is utilized in order to minimize the noise contribution and to minimize dynamic impact on the amplifier input nodes. The method for signal recovery from noisy nerve signals is presented. A prototype amplifier is realized in a standard digital 0...

  10. Fast logarithmic amplifier

    International Nuclear Information System (INIS)

    Tai, I.; Hasegawa, K.

    1975-01-01

    This paper reports on the improvement of frequency characteristics of a logarithmic amplifier with a Paterson transdiode connection. The improvement of the response speed has been achieved by using a phase compensation technique. Small signal response analyses of the logging circuit revealed the effects of a series resistor Rsub(p) and a parallel capacitance Csub(p) on the response of the circuit. The improvement of the frequency characteristics are remarkable at higher current levels. These facts were proved by the practical logarithmic amplifier. (auth.)

  11. Flashlamp excited fluid laser amplified

    International Nuclear Information System (INIS)

    1976-01-01

    The patent describes a laser amplifier with chambers for containing and amplifying an intensifier medium. It serves the need for a large impulse repetition rate and high intensities as required e.g. for laser isotope separation

  12. Design considerations for RF power amplifiers demonstrated through a GSM/EDGE power amplifier module

    NARCIS (Netherlands)

    Baltus, P.G.M.; Bezooijen, van A.; Huijsing, J.H.; Steyaert, M.; Roermund, van A.H.M.

    2002-01-01

    This paper describes the design considerations for RF power amplifiers in general, including trends in systems, linearity and efficiency, the PA environment, implementation is sues and technology. As an example a triple-band (900/1800/1900MHz) dual mode (GSMIEdge) power amplifier module is described

  13. Challenges in higher order mode Raman amplifiers

    DEFF Research Database (Denmark)

    Rottwitt, Karsten; Nielsen, Kristian; Friis, Søren Michael Mørk

    2015-01-01

    A higher order Raman amplifier model that take random mode coupling into account ispresented. Mode dependent gain and signal power fluctuations at the output of the higher order modeRaman amplifier are discussed......A higher order Raman amplifier model that take random mode coupling into account ispresented. Mode dependent gain and signal power fluctuations at the output of the higher order modeRaman amplifier are discussed...

  14. S-band low noise amplifier and 40 kW high power amplifier subsystems of Japanese Deep Space Earth Station

    Science.gov (United States)

    Honma, K.; Handa, K.; Akinaga, W.; Doi, M.; Matsuzaki, O.

    This paper describes the design and the performance of the S-band low noise amplifier and the S-band high power amplifier that have been developed for the Usuda Deep Space Station of the Institute of Space and Astronautical Science (ISAS), Japan. The S-band low noise amplifier consists of a helium gas-cooled parametric amplifier followed by three-stage FET amplifiers and has a noise temperature of 8 K. The high power amplifier is composed of two 28 kW klystrons, capable of transmitting 40 kW continuously when two klystrons are combined. Both subsystems are operating quite satisfactorily in the tracking of Sakigake and Suisei, the Japanese interplanetary probes for Halley's comet exploration, launched by ISAS in 1985.

  15. Formation and rearrangement of homoserine depsipeptides and depsiproteins in the α-ketoacid-hydroxylamine ligation with 5-oxaproline.

    Science.gov (United States)

    Wucherpfennig, Thomas G; Rohrbacher, Florian; Pattabiraman, Vijaya R; Bode, Jeffrey W

    2014-11-03

    The primary products of the chemical ligation of α-ketoacids and 5-oxaproline peptides are esters, rather than the previously reported amides. The depsipeptide product rapidly rearranges to the amide in basic buffers. The formation of esters sheds light on possible mechanisms for the type II KAHA ligations and opens an avenue for the chemical synthesis of depsiproteins. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Ligation of major histocompatibility complex class I antigens (MHC-I) prevents apoptosis induced by Fas or SAPK/JNK activation in T-lymphoma cells

    DEFF Research Database (Denmark)

    Lamberth, K; Claesson, M H

    2001-01-01

    Early apoptosis in Jurkat T-lymphoma cells was induced by agonistic anti-Fas Ab or by anisomycin which activates the stress kinases SAPK/JNK. Apoptosis was inhibited by ligation of major histocompatibility complex class I antigens (MHC-I). MHC-I ligation induced upregulation of the anti......-apoptotic Bcl-2 protein and stabilized the mitochondrial membrane potential (Deltapsim). MHC-I ligation also prevented downregulation of Bcl-2 and destabilization of Deltapsim induced by anti-Fas Ab treatment or anisomycin exposure. Studies on three different Jurkat cell mutants deficient for src p56(lck), ZAP......-70 kinase, or TCR/CD3 gamma-chain showed that the cells undergo apoptosis after Fas ligation. Anisomycin exposure induced apoptosis in the src p56(lck)-deficient cell line but not in the two other mutant cell lines. Simultaneous cross-linking of MHC-I and Fas ligation inhibited apoptosis in the ZAP...

  17. Small signal microwave amplifier design

    CERN Document Server

    Grosch, Theodore

    2000-01-01

    This book explains techniques and examples for designing stable amplifiers for high-frequency applications in which the signal is small and the amplifier circuit is linear. An in-depth discussion of linear network theory provides the foundation needed to develop actual designs. Examples throughout the book will show you how to apply the knowledge gained in each chapter leading to the complex design of low noise amplifiers. Many exercises at the end of each chapter will help students to practice their skills. The solutions to these design problems are available in an accompanying solutions book

  18. Angiographic findings of collateral vessels in cervicofacial vascular lesions with previously ligated carotid artery

    International Nuclear Information System (INIS)

    Na, Dong Gyu; Han, Moon Hee; Chang, Kee Hyun; Han, Gi Seok; Yeon, Kung Mo

    1995-01-01

    The purpose of this study is to describe the angiographic findings of collateral vessels in cervicofacial vascular lesions with previously ligated carotid arteries and to evaluate the extent of angiographic assessment needed before embolization. We retrospectively reviewed 10 cervicofacial vascular lesions with previously ligated carotid artery, which were 6 cases of arteriovenous malformation, 2 cases of carotid cavernous fistula, 1 case of hemangioma and 1 case of arteriovenous malformation with carotid cavernous fistula. The previously ligated arteries are proximal external carotid artery (n = 5), branches of external carotid artery (n = 2) and common carotid artery (n = 3). Common carotid artery or internal carotid artery (n = 9), vertebral artery (n = 5), ipsilateral external carotid artery (n = 4), contralateral external carotid artery (n = 5), costocervical trunk (n = 2), thyrocervical trunk (n = 2) were assessed by conventional angiography. Angiography of both carotid and vertebral arteries was performed in 5 cases. The collateral vascular channels were inferolateral trunk of internal carotid artery (n = 8), vertebral artery (n = 5), contralateral external carotid artery (n = 5), ipsilateral external carotid artery (n = 4), deep cervical artery (n = 2) and ascending cervical artery (n = 1). Embolization were performed in 9 cases with operative cannulation (n = 4), embolization via collateral branches of ipsilateral external carotid artery (n = 1), embolization via collateral branches of contralateral external carotid artery (n = 3) and balloon occlusion via direct puncture (n = 1). The collateral channels in cervicofacial vascular lesions with previously ligated carotid artery were inferolateral trunk of internal carotid artery, contralateral or ipsilateral external carotid artery, vertebral artery, deep cervical artery and ascending cervical artery on angiography. Complete angiographic assessment of possible collateral channels is mandatory for the

  19. Chemical Synthesis of the 20 kDa Heme Protein Nitrophorin 4 by α-Ketoacid-Hydroxylamine (KAHA) Ligation.

    Science.gov (United States)

    He, Chunmao; Kulkarni, Sameer S; Thuaud, Frédéric; Bode, Jeffrey W

    2015-10-26

    The chemical synthesis of the 184-residue ferric heme-binding protein nitrophorin 4 was accomplished by sequential couplings of five unprotected peptide segments using α-ketoacid-hydroxylamine (KAHA) ligation reactions. The fully assembled protein was folded to its native structure and coordinated to the ferric heme b cofactor. The synthetic holoprotein, despite four homoserine residues at the ligation sites, showed identical properties to the wild-type protein in nitric oxide binding and nitrite dismutase reactivity. This work establishes the KAHA ligation as a valuable and viable approach for the chemical synthesis of proteins up to 20 kDa and demonstrates that it is well-suited for the preparation of hydrophobic protein targets. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Sequence-Related Amplified Polymorphism (SRAP Markers: A Potential Resource for Studies in Plant Molecular Biology

    Directory of Open Access Journals (Sweden)

    Daniel W. H. Robarts

    2014-07-01

    Full Text Available In the past few decades, many investigations in the field of plant biology have employed selectively neutral, multilocus, dominant markers such as inter-simple sequence repeat (ISSR, random-amplified polymorphic DNA (RAPD, and amplified fragment length polymorphism (AFLP to address hypotheses at lower taxonomic levels. More recently, sequence-related amplified polymorphism (SRAP markers have been developed, which are used to amplify coding regions of DNA with primers targeting open reading frames. These markers have proven to be robust and highly variable, on par with AFLP, and are attained through a significantly less technically demanding process. SRAP markers have been used primarily for agronomic and horticultural purposes, developing quantitative trait loci in advanced hybrids and assessing genetic diversity of large germplasm collections. Here, we suggest that SRAP markers should be employed for research addressing hypotheses in plant systematics, biogeography, conservation, ecology, and beyond. We provide an overview of the SRAP literature to date, review descriptive statistics of SRAP markers in a subset of 171 publications, and present relevant case studies to demonstrate the applicability of SRAP markers to the diverse field of plant biology. Results of these selected works indicate that SRAP markers have the potential to enhance the current suite of molecular tools in a diversity of fields by providing an easy-to-use. highly variable marker with inherent biological significance.

  1. An in vitro study into the efficacy of complex tooth alignment with conventional and self-ligating brackets.

    Science.gov (United States)

    Montasser, M A; Keilig, L; Bourauel, C

    2015-02-01

    To evaluate the efficacy of tooth alignment achieved by various small cross-section archwire/bracket combinations using the orthodontic measurement and simulation system. The study comprised three types of orthodontic brackets 1) conventional ligating (Victory Series and Mini-Taurus), 2) self-ligating (SmartClip a passive self-ligating bracket and Time3 an active self-ligating bracket), and 3) a conventional low-friction bracket (Synergy). All brackets had a nominal 0.022″ slot size. Brackets were combined with 1) 0.012″ stainless steel, 2) 0.012″ Orthonol, 3) 0.012″ Thermalloy, and 4) 0.0155″ coaxial archwires. Archwires were tied to the conventional brackets with stainless steel ligatures and elastomeric rings. The malocclusion simulated represented a central upper incisor displaced 2 mm gingivally (x-axis) and 2 mm labially (z-axis). The inciso-gingival correction achieved by the different archwire/bracket combinations ranged from 15 to 95%, while the labio-lingual correction ranged from 10 to 95%. The smallest correction was achieved by coaxial, Orthonol, and thermally archwires when ligated with the elastomeric rings to conventional brackets. Stainless steel archwires achieved from 65 to 90% of inciso-gingival correction and from 60 to 90% of labio-lingual correction. The resultant tooth alignment was the product of interaction between the archwire type, bracket type, and bracket design including ligature type. Small cross-sectional archwires might produce up to 95% correction if combined properly with the bracket system. Elastomeric rings when used with conventional brackets limit the efficacy of malalignment correction. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Consecutive native chemical ligation-route to synthetic mouse prion protein

    Czech Academy of Sciences Publication Activity Database

    Zawada, Zbigniew; Šebestík, Jaroslav; Šafařík, Martin; Březinová, Anna; Bouř, Petr; Hlaváček, Jan; Stibor, Ivan

    2009-01-01

    Roč. 103, č. 11 (2009), s. 1001-1001 ISSN 0009-2770. [Pokroky v organické, bioorganické a farmaceutické chemii /44./. 27.11.2009-29.11.2009, Liblice] R&D Projects: GA ČR GA203/07/1517 Institutional research plan: CEZ:AV0Z40550506 Keywords : prion * chemical ligation Subject RIV: CC - Organic Chemistry

  3. Assessment and treatment of post patent ductus arteriosus ligation syndrome.

    LENUS (Irish Health Repository)

    El-Khuffash, Afif F

    2014-07-01

    To compare differences in tissue Doppler imaging, global longitudinal strain (GLS), and cardiac troponin T (cTnT) between infants with low (<200 mL\\/kg\\/min) and high (>200 mL\\/kg\\/min) left ventricular (LV) output 1 hour after duct ligation and assess the impact of milrinone treatment on cardiac output and myocardial performance.

  4. Noise in Optical Amplifiers

    DEFF Research Database (Denmark)

    Jeppesen, Palle

    1997-01-01

    Noise in optical amplifiers is discussed on the basis of photons and electromagntic fields. Formulas for quantum noise from spontaneous emission, signal-spontaneous beat noise and spontaneous-spontaneous beat noise are derived.......Noise in optical amplifiers is discussed on the basis of photons and electromagntic fields. Formulas for quantum noise from spontaneous emission, signal-spontaneous beat noise and spontaneous-spontaneous beat noise are derived....

  5. Amplified spontaneous emissions in a high-gain laser amplifier

    International Nuclear Information System (INIS)

    Osada, Hidenori; Gamo, Hideya.

    1978-01-01

    The gain and line-narrowing of the amplified spontaneous emissions(ASE) in a partially homogeneous high-gain Xe 3.51 μm laser amplifier were studied theoretically and experimentally with emphasis of saturation effect. The unidirectionally travelling ASE was generated by conveniently using optical isolators and used as a broadband radiation source. It has properties of 10 μW/mm 2 in intensity with fluctuation of less than 1% in 5 hours, 43.5 MHz of the linewidth and 1.0 x 10 -3 radians of beam divergence. The measured saturation intensity was 4.85 μW/mm 2 and a small signal gain was 0.1 cm -1 . The theoretical prediction of the line-narrowing shows reasonablly good agreement with the measured one. (author)

  6. Dual-range linearized transimpedance amplifier system

    Science.gov (United States)

    Wessendorf, Kurt O.

    2010-11-02

    A transimpedance amplifier system is disclosed which simultaneously generates a low-gain output signal and a high-gain output signal from an input current signal using a single transimpedance amplifier having two different feedback loops with different amplification factors to generate two different output voltage signals. One of the feedback loops includes a resistor, and the other feedback loop includes another resistor in series with one or more diodes. The transimpedance amplifier system includes a signal linearizer to linearize one or both of the low- and high-gain output signals by scaling and adding the two output voltage signals from the transimpedance amplifier. The signal linearizer can be formed either as an analog device using one or two summing amplifiers, or alternately can be formed as a digital device using two analog-to-digital converters and a digital signal processor (e.g. a microprocessor or a computer).

  7. Detection of Non-Amplified Genomic DNA

    CERN Document Server

    Corradini, Roberto

    2012-01-01

    This book offers a state-of-the-art overview on non amplified DNA detection methods and provides chemists, biochemists, biotechnologists and material scientists with an introduction to these methods. In fact all these fields have dedicated resources to the problem of nucleic acid detection, each contributing with their own specific methods and concepts. This book will explain the basic principles of the different non amplified DNA detection methods available, highlighting their respective advantages and limitations. The importance of non-amplified DNA sequencing technologies will be also discussed. Non-amplified DNA detection can be achieved by adopting different techniques. Such techniques have allowed the commercialization of innovative platforms for DNA detection that are expected to break into the DNA diagnostics market. The enhanced sensitivity required for the detection of non amplified genomic DNA has prompted new strategies that can achieve ultrasensitivity by combining specific materials with specifi...

  8. A bipyridine-ligated zinc(II) complex with bridging flavonolate ligation: synthesis, characterization, and visible-light-induced CO release reactivity.

    Science.gov (United States)

    Sorenson, Shayne; Popova, Marina; Arif, Atta M; Berreau, Lisa M

    2017-09-01

    Metal-flavonolate compounds are of significant current interest as synthetic models for quercetinase enzymes and as bioactive compounds of importance to human health. Zinc-3-hydroxyflavonolate compounds, including those of quercetin, kampferol, and morin, generally exhibit bidentate coordination to a single Zn II center. The bipyridine-ligated zinc-flavonolate compound reported herein, namely bis(μ-4-oxo-2-phenyl-4H-chromen-3-olato)-κ 3 O 3 :O 3 ,O 4 ;κ 3 O 3 ,O 4 :O 3 -bis[(2,2'-bipyridine-κ 2 N,N')zinc(II)] bis(perchlorate), {[Zn 2 (C 15 H 9 O 3 ) 2 (C 10 H 8 N 2 ) 2 ](ClO 4 ) 2 } n , (1), provides an unusual example of bridging 3-hydroxyflavonolate ligation in a dinuclear metal complex. The symmetry-related Zn II centers of (1) exhibit a distorted octahedral geometry, with weak coordination of a perchlorate anion trans to the bridging deprotonated O atom of the flavonolate ligand. Variable-concentration conductivity measurements provide evidence that, when (1) is dissolved in CH 3 CN, the complex dissociates into monomers. 1 H NMR resonances for (1) dissolved in d 6 -DMSO were assigned via HMQC to the H atoms of the flavonolate and bipyridine ligands. In CH 3 CN, (1) undergoes quantitative visible-light-induced CO release with a quantum yield [0.004 (1)] similar to that exhibited by other mononuclear zinc-3-hydroxyflavonolate complexes. Mass spectroscopic identification of the [(bpy) 2 Zn(O-benzoylsalicylate)] + ion provides evidence of CO release from the flavonol and of ligand exchange at the Zn II center.

  9. An Implantable CMOS Amplifier for Nerve Signals

    DEFF Research Database (Denmark)

    Nielsen, Jannik Hammel; Lehmann, Torsten

    2001-01-01

    In this paper, a low noise high gain CMOS amplifier for minute nerve signals is presented. By using a mixture of weak- and strong inversion transistors, optimal noise suppression in the amplifier is achieved. A continuous-time offset-compensation technique is utilized in order to minimize impact...... on the amplifier input nodes. The method for signal recovery from noisy nerve signals is presented. A prototype amplifier is realized in a standard digital 0.5 μm CMOS single poly, n-well process. The prototype amplifier features a gain of 80 dB over a 3.6 kHz bandwidth, a CMRR of more than 87 dB and a PSRR...

  10. Ligation of MHC class I molecules on peripheral blood T lymphocytes induces new phenotypes and functions

    DEFF Research Database (Denmark)

    Bregenholt, S; Röpke, M; Skov, S

    1996-01-01

    of T cell-mediated cytotoxicity. Immediately following MHC-I ligation, the T cells responded with increased protein tyrosine phosphorylation, with new bands appearing in the SDS-PAGE. Exposure of T cells to immobilized anti-MHC-I Ab for 24 h induced an increased surface expression of the TCR/CD3 and CD......28 molecules. MHC-I-induced proliferation of purified T cells was dependent on cellular interactions with non-T cells. Under certain conditions, in which MHC-I was ligated by picogram concentrations of immobilized anti-MHC-I Ab, anti-TCR/CD3 Ab-induced proliferation of T cells was strongly inhibited....... These data clearly demonstrate that ligation of the MHC-I complex on T cells may induce both positive and negative signals. Since the physiologic ligands for MHC-I molecules are TCR and the CD8 molecules, our data may suggest that MHC-I molecules are instrumental in cellular interactions between T cells....

  11. Authentic interdomain communication in an RNA helicase reconstituted by expressed protein ligation of two helicase domains.

    Science.gov (United States)

    Karow, Anne R; Theissen, Bettina; Klostermeier, Dagmar

    2007-01-01

    RNA helicases mediate structural rearrangements of RNA or RNA-protein complexes at the expense of ATP hydrolysis. Members of the DEAD box helicase family consist of two flexibly connected helicase domains. They share nine conserved sequence motifs that are involved in nucleotide binding and hydrolysis, RNA binding, and helicase activity. Most of these motifs line the cleft between the two helicase domains, and extensive communication between them is required for RNA unwinding. The two helicase domains of the Bacillus subtilis RNA helicase YxiN were produced separately as intein fusions, and a functional RNA helicase was generated by expressed protein ligation. The ligated helicase binds adenine nucleotides with very similar affinities to the wild-type protein. Importantly, its intrinsically low ATPase activity is stimulated by RNA, and the Michaelis-Menten parameters are similar to those of the wild-type. Finally, ligated YxiN unwinds a minimal RNA substrate to an extent comparable to that of the wild-type helicase, confirming authentic interdomain communication.

  12. Operational amplifiers theory and design

    CERN Document Server

    Huijsing, Johan

    2017-01-01

    This proven textbook guides readers to a thorough understanding of the theory and design of operational amplifiers (OpAmps). The core of the book presents systematically the design of operational amplifiers, classifying them into a periodic system of nine main overall configurations, ranging from one gain stage up to four or more stages. This division enables circuit designers to recognize quickly, understand, and choose optimal configurations. Characterization of operational amplifiers is given by macro models and error matrices, together with measurement techniques for their parameters. Definitions are given for four types of operational amplifiers depending on the grounding of their input and output ports. Many famous designs are evaluated in depth, using a carefully structured approach enhanced by numerous figures. In order to reinforce the concepts introduced and facilitate self-evaluation of design skills, the author includes problems with detailed solutions, as well as simulation exercises. Provides te...

  13. Intravesical ligation as a new technique to manage a refluxing native ureter without simultaneous nephrectomy in renal transplantation.

    Science.gov (United States)

    Guzmán, J A

    2012-12-01

    This article aims to describe an original technique to correct refluxing native ureters observed during a prerenal transplantation study. The correction is performed by intravesical ligation of the native refluxing ureters at the same time as renal transplantation without simultaneous nephrectomy. Between January 2004 and December 2010 we performed intravesical ligation of a refluxing ureter simultaneous with a transplantation procedure without a concomittant native nephrectomy in 12 of 345 subjects (3.47%). The 8 bilateral and 4 unilateral ligations were performed on 11 cadaveric and 1 living-related nonidentical donor transplantations. The implantation of the kidney donor ureter was performed anatomically in the bladder trigone through a transvesical ureteroneocystostomy with a transmural, submucosal antireflux tunnel. Early and late postoperative recovery was satisfactory in all patients. There was no documented kidney area pain, proven urinary tract infection, morbidity or mortality attributed to the procedure. Intravesical ligation is a practical technique to manage vesicoureteral reflux into the native ureters simultaneously with the ureteral implantation of the kidney donor in a single surgical renal transplant procedure without native kidney nephrectomy. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Wideband Low Noise Amplifiers Exploiting Thermal Noise Cancellation

    NARCIS (Netherlands)

    Bruccoleri, F.; Klumperink, Eric A.M.; Nauta, Bram

    2005-01-01

    Low Noise Amplifiers (LNAs) are commonly used to amplify signals that are too weak for direct processing for example in radio or cable receivers. Traditionally, low noise amplifiers are implemented via tuned amplifiers, exploiting inductors and capacitors in resonating LC-circuits. This can render

  15. Isolation and screening of microsatellite markers from the pearl ...

    Indian Academy of Sciences (India)

    DNA was simultaneously digested with. MseI and ligated to MseI-adaptor. The digestion ligation mixture was diluted (1:10) and directly amplified with. ∗For correspondence. E-mail: pearlydh@163.com. AFLP adaptor-specific primers. The PCR product was then hybridized with a biotinylated (CA)15 probe. DNA molecules.

  16. Management of Fistula‑In‑Ano with Special Reference to Ligation of ...

    African Journals Online (AJOL)

    Context: The surgical management of fistula-in-ano is still debatable and no clear recommendations have been made available until now. The present study analyses the results of ligation of intersphincteric fistula tract (LIFT) technique in treating fistula-in-ano in particular with recurrence, healing time, and continence status.

  17. Phase noise in RF and microwave amplifiers.

    Science.gov (United States)

    Boudot, Rodolphe; Rubiola, Enrico

    2012-12-01

    Understanding amplifier phase noise is a critical issue in many fields of engineering and physics, such as oscillators, frequency synthesis, telecommunication, radar, and spectroscopy; in the emerging domain of microwave photonics; and in exotic fields, such as radio astronomy, particle accelerators, etc. Focusing on the two main types of base noise in amplifiers, white and flicker, the power spectral density of the random phase φ(t) is Sφ(f) = b(0) + b(-1)/f. White phase noise results from adding white noise to the RF spectrum in the carrier region. For a given RF noise level, b(0) is proportional to the reciprocal of the carrier power P(0). By contrast, flicker results from a near-dc 1/f noise-present in all electronic devices-which modulates the carrier through some parametric effect in the semiconductor. Thus, b(-1) is a parameter of the amplifier, constant in a wide range of P(0). The consequences are the following: Connecting m equal amplifiers in parallel, b(-1) is 1/m times that of one device. Cascading m equal amplifiers, b(-1) is m times that of one amplifier. Recirculating the signal in an amplifier so that the gain increases by a power of m (a factor of m in decibels) as a result of positive feedback (regeneration), we find that b(-1) is m(2) times that of the amplifier alone. The feedforward amplifier exhibits extremely low b(-1) because the carrier is ideally nulled at the input of its internal error amplifier. Starting with an extensive review of the literature, this article introduces a system-oriented model which describes the phase flickering. Several amplifier architectures (cascaded, parallel, etc.) are analyzed systematically, deriving the phase noise from the general model. There follow numerous measurements of amplifiers using different technologies, including some old samples, and in a wide frequency range (HF to microwaves), which validate the theory. In turn, theory and results provide design guidelines and give suggestions for CAD and

  18. Plaque retention by self-ligating vs elastomeric orthodontic brackets: quantitative comparison of oral bacteria and detection with adenosine triphosphate-driven bioluminescence.

    NARCIS (Netherlands)

    Pellegrini, P.; Sauerwein, R.W.; Finlayson, T.; McLeod, J.; Covell, D.A.; Maier, T.; Machida, C.A.

    2009-01-01

    INTRODUCTION: Enamel decalcification is a common problem in orthodontics. The objectives of this randomized clinical study were to enumerate and compare plaque bacteria surrounding 2 bracket types, self-ligating (SL) vs elastomeric ligating (E), and to determine whether adenosine triphosphate

  19. Enhanced Gain in Photonic Crystal Amplifiers

    DEFF Research Database (Denmark)

    Ek, Sara; Semenova, Elizaveta; Hansen, Per Lunnemann

    2012-01-01

    We experimentally demonstrate enhanced gain in the slow-light regime of quantum well photonic crystal amplifiers. A strong gain enhancement is observed with the increase of the group refractive index, due to light slow-down. The slow light enhancement is shown in a amplified spontaneous emission....... These results are promising for short and efficient semiconductor optical amplifiers. This effect will also benefit other devices, such as mode locked lasers....

  20. Level of arterial ligation in sigmoid colon and rectal cancer surgery.

    Science.gov (United States)

    Yasuda, Koji; Kawai, Kazushige; Ishihara, Soichiro; Murono, Koji; Otani, Kensuke; Nishikawa, Takeshi; Tanaka, Toshiaki; Kiyomatsu, Tomomichi; Hata, Keisuke; Nozawa, Hiroaki; Yamaguchi, Hironori; Aoki, Shigeo; Mishima, Hideyuki; Maruyama, Tsunehiko; Sako, Akihiro; Watanabe, Toshiaki

    2016-04-01

    Curative resection of sigmoid colon and rectal cancer includes "high tie" of the inferior mesenteric artery (IMA). However, IMA ligation compromises blood flow to the anastomosis, which may increase the leakage rate, and it is unclear whether this confers a survival advantage. Accordingly, the IMA may be ligated at a point just below the origin of the left colic artery (LCA) "low tie" combined with lymph node dissection (LND) around the origin of the IMA (low tie with LND). However, no study has investigated the detailed prognostic results between "high tie" and "low tie with LND." The aim of this study was to assess the utility of "low tie with LND" on survival in patients with sigmoid colon or rectal cancer. A total of 189 sigmoid colon or rectal cancer patients who underwent curative operation from 1997 to 2007 were enrolled in this study. The patient's medical records were reviewed to obtain clinicopathological information. Overall survival (OS) and relapse-free survival (RFS) rates were calculated using the Kaplan-Meier method, with differences assessed using log-rank test. Forty-two and 147 patients were ligated at the origin of the IMA (high tie) and just below the origin of the LCA combined with LND around the origin of the IMA (low tie with LND), respectively. No significant differences were observed in the complication rate and OS and RFS rates in the two groups. Further, no significant difference was observed in the OS and RFS rates in the lymph node-positive cases in the two groups. "Low tie with LND" is anatomically less invasive and is not inferior to "high tie" with prognostic point of view.

  1. Native chemical ligation at Asx-Cys, Glx-Cys: chemical synthesis and high-resolution X-ray structure of ShK toxin by racemic protein crystallography.

    Science.gov (United States)

    Dang, Bobo; Kubota, Tomoya; Mandal, Kalyaneswar; Bezanilla, Francisco; Kent, Stephen B H

    2013-08-14

    We have re-examined the utility of native chemical ligation at -Gln/Glu-Cys- [Glx-Cys] and -Asn/Asp-Cys- [Asx-Cys] sites. Using the improved thioaryl catalyst 4-mercaptophenylacetic acid (MPAA), native chemical ligation could be performed at -Gln-Cys- and Asn-Cys- sites without side reactions. After optimization, ligation at a -Glu-Cys- site could also be used as a ligation site, with minimal levels of byproduct formation. However, -Asp-Cys- is not appropriate for use as a site for native chemical ligation because of formation of significant amounts of β-linked byproduct. The feasibility of native chemical ligation at -Gln-Cys- enabled a convergent total chemical synthesis of the enantiomeric forms of the ShK toxin protein molecule. The D-ShK protein molecule was ~50,000-fold less active in blocking the Kv1.3 channel than the L-ShK protein molecule. Racemic protein crystallography was used to obtain high-resolution X-ray diffraction data for ShK toxin. The structure was solved by direct methods and showed significant differences from the previously reported NMR structures in some regions of the ShK protein molecule.

  2. A comparison of lower canine retraction and loss of anchorage between conventional and self-ligating brackets: a single-center randomized split-mouth controlled trial.

    Science.gov (United States)

    da Costa Monini, André; Júnior, Luiz Gonzaga Gandini; Vianna, Alexandre Protásio; Martins, Renato Parsekian

    2017-05-01

    To evaluate the rate of lower canine retraction, anchorage loss, and changes on lower canines and first molars axial inclination using self-ligating and conventional brackets. Twenty-five adult patients with a treatment plan involving extractions of four first premolars were selected for this split-mouth trial and had either conventional or self-ligating brackets bonded to lower canines in a block randomization. Retraction was accomplished using 100-g nickel titanium closed-coil springs, which were reactivated each 4 weeks. Oblique radiographs were taken before and after total canine retraction and the cephalograms were superimposed on stable structures of the mandible. Cephalometric points were digitized twice by a single-blinded operator for error control and the average of the points were used to determine the following variables: canine cusp horizontal changes, molar cusp horizontal changes, and angulation changes in canines and molars. Paired t tests were used to analyze the blinded data for group differences. All patients reached final phase without bracket debonds. No differences were found between the two groups for all variables tested. No serious harm was observed. Both brackets showed the same rate of canine retraction and loss of anteroposterior anchorage of the molars. No changes were found between brackets regarding the inclination of canines and first molars. Using self-ligating brackets to retract lower canines will not increase the velocity of tooth movement, does not increase anchorage, and does not decrease tipping.

  3. Comparison of frictional resistance between self-ligating and conventional brackets tied with elastomeric and metal ligature in orthodontic archwires.

    Science.gov (United States)

    Leite, Vanessa Vieira; Lopes, Murilo Baena; Gonini Júnior, Alcides; Almeida, Marcio Rodrigues de; Moura, Sandra Kiss; Almeida, Renato Rodrigues de

    2014-01-01

    To compare the frictional resistance between self-ligating and conventional brackets tied to different types of wire. Abzil Kirium Capelozza (Pattern I) and Easy Clip (Roth prescription) incisor brackets were used. An elastomeric ligature or a 0.10-in ligating wire was used to ligate the wire to the Abzil bracket. Three types of orthodontic archwire alloys were assessed: 0.016-in NiTi wire, 0.016 x 0.021-in NiTi wire and 0.019 x 0.025-in steel wire. Ten observations were carried out for each bracket-archwire angulation combination. Brackets were mounted in a special appliance, positioned at 90 degrees in relation to the wire and tested in two angulations. Frictional test was performed in a Universal Testing Machine at 5 mm/min and 10 mm of displacement. The means (MPa) were submitted to ANOVA and Tukey's test set at 5% of significance. The surfaces of wires and brackets were observed at SEM. Steel-tied brackets (16.48 ± 8.31) showed higher means of frictional resistance than elastomeric-tied brackets (4.29 ± 2.16 ) and self-ligating brackets (1.66 ± 1.57) (P 0.05). No statistical differences (P > 0.05) were found between zero (7.76 ± 8.46) and five-degree (7.19 ± 7.93) angulations. Friction was influenced not only by the type of bracket, but also by the ligating systems. Different morphological aspects were observed for the brackets and wires studied.

  4. Comparative study of friction between metallic and conventional interactive self-ligating brackets in different alignment conditions.

    Science.gov (United States)

    Jakob, Sérgio Ricardo; Matheus, Davison; Jimenez-Pellegrin, Maria Cristina; Turssi, Cecília Pedroso; Amaral, Flávia Lucisano Botelho

    2014-01-01

    The aim of this study was to compare the friction between three bracket models: conventional stainless steel (Ovation, Dentsply GAC), self-ligating ceramic (In-Ovation, Denstply GAC) and self-ligating stainless steel brackets (In-Ovation R, Dentsply GAC). Five brackets were used for each model. They were bonded to an aluminum prototype that allowed the simulation of four misalignment situations (n = 10). Three of these situations occured at the initial phase (in which a 0.016-in nickel-titanium wire was used): 1. horizontal; 2. vertical; and 3. simultaneous horizontal/vertical. One of the situations occurred at the final treatment phase: 4. no misalignment (in which a 0.019 x 0.025-inch stainless steel rectangular wire was used). The wires slipped through the brackets and friction was measured by a Universal Testing Machine. Analysis of variance followed by Tukey's Test for multiple comparisons (α = 0.05) were applied to assess the results. Significant interaction (p friction. The two self-ligating models resulted in lower and similar values, except for the horizontal situation, in which In-Ovation C® showed lower friction, which was similar to the In-Ovation R® metallic model. For the no misalignment situation, the same results were observed. The self-ligating system was superior to the conventional one due to producing less friction. With regard to the material used for manufacturing the brackets, the In-Ovation C® ceramic model showed less friction than the metallic ones.

  5. In vivo and in vitro protein ligation by naturally occurring and engineered split DnaE inteins.

    Directory of Open Access Journals (Sweden)

    A Sesilja Aranko

    Full Text Available BACKGROUND: Protein trans-splicing by naturally occurring split DnaE inteins is used for protein ligation of foreign peptide fragments. In order to widen biotechnological applications of protein trans-splicing, it is highly desirable to have split inteins with shorter C-terminal fragments, which can be chemically synthesized. PRINCIPAL FINDINGS: We report the identification of new functional split sites in DnaE inteins from Synechocystis sp. PCC6803 and from Nostoc punctiforme. One of the newly engineered split intein bearing C-terminal 15 residues showed more robust protein trans-splicing activity than naturally occurring split DnaE inteins in a foreign context. During the course of our experiments, we found that protein ligation by protein trans-splicing depended not only on the splicing junction sequences, but also on the foreign extein sequences. Furthermore, we could classify the protein trans-splicing reactions in foreign contexts with a simple kinetic model into three groups according to their kinetic parameters in the presence of various reducing agents. CONCLUSION: The shorter C-intein of the newly engineered split intein could be a useful tool for biotechnological applications including protein modification, incorporation of chemical probes, and segmental isotopic labelling. Based on kinetic analysis of the protein splicing reactions, we propose a general strategy to improve ligation yields by protein trans-splicing, which could significantly enhance the applications of protein ligation by protein trans-splicing.

  6. Dual frequency parametric excitation of a nonlinear, multi degree of freedom mechanical amplifier with electronically modified topology

    Science.gov (United States)

    Dolev, A.; Bucher, I.

    2018-04-01

    Mechanical or electromechanical amplifiers can exploit the high-Q and low noise features of mechanical resonance, in particular when parametric excitation is employed. Multi-frequency parametric excitation introduces tunability and is able to project weak input signals on a selected resonance. The present paper addresses multi degree of freedom mechanical amplifiers or resonators whose analysis and features require treatment of the spatial as well as temporal behavior. In some cases, virtual electronic coupling can alter the given topology of the resonator to better amplify specific inputs. An analytical development is followed by a numerical and experimental sensitivity and performance verifications, illustrating the advantages and disadvantages of such topologies.

  7. A system for biasing a differential amplifier

    International Nuclear Information System (INIS)

    Barbier, Daniel; Ittel, J.M.; Poujois, Robert

    1975-01-01

    This invention concerns a system for biasing a differential amplifier. It particularly applies to the integrated differential amplifiers designed with MOS field effect transistors. Variations in the technological parameters may well cause the amplifying transistors to work outside their usual operational area, in other words outside the linear part of the transfer characteristic. To ensure that these transistors function correctly, it is necessary that the value of the voltage difference at the output be equally null. To do this and to centre on the so called 'rest' point of the amplifier transfer charateristic, the condition will be set that the output potentials of each amplifier transistor should have a zero value or a constant value as sum. With this in view, the bias on the source (generally a transistor powered by its grid bias voltage) supplying current to the two amplifying transistors fitted in parallel, is permanently adjusted in a suitable manner [fr

  8. A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type

    Science.gov (United States)

    Lee, Souk Min

    2015-01-01

    Objective This study aimed to compare the frictional force (FR) in self-ligating brackets among different bracket-archwire angles, bracket materials, and archwire types. Methods Passive and active metal self-ligating brackets and active ceramic self-ligating brackets were included as experimental groups, while conventional twin metal brackets served as a control group. All brackets were maxillary premolar brackets with 0.022 inch [in] slots and a -7° torque. The orthodontic wires used included 0.018 round and 0.019 × 0.025 in rectangular stainless steel wires. The FR was measured at 0°, 5°, and 10° angulations as the wire was drawn through the bracket slots after attaching brackets from each group to the universal testing machine. Static and kinetic FRs were also measured. Results The passive self-ligating brackets generated a lower FR than all the other brackets. Static and kinetic FRs generally increased with an increase in the bracket-archwire angulation, and the rectangular wire caused significantly higher static and kinetic FRs than the round wire (p brackets exhibited the lowest static FR at the 0° angulation and a lower increase in static and kinetic FRs with an increase in bracket-archwire angulation than the other brackets, while the conventional twin brackets showed a greater increase than all three experimental brackets. Conclusions The passive self-ligating brackets showed the lowest FR in this study. Self-ligating brackets can generate varying FRs in vitro according to the wire size, surface characteristics, and bracket-archwire angulation. PMID:25667913

  9. Solid-state disk amplifiers for fusion-laser systems

    Energy Technology Data Exchange (ETDEWEB)

    Martin, W.E.; Trenholme, J.B.; Linford, G.J.; Yarema, S.M.; Hurley, C.A.

    1981-09-01

    We review the design, performance, and operation of large-aperture (10 to 46 cm) solid-state disk amplifiers for use in laser systems. We present design data, prototype tests, simulations, and projections for conventional cylindrical pump-geometry amplifiers and rectangular pump-geometry disk amplifiers. The design of amplifiers for the Nova laser system is discussed.

  10. Some characteristic features of the construction of the amplifying channel for working with semiconductor detectors in the charged particle energy spectrometer. [noise minimization at preamplifier input

    Science.gov (United States)

    Kuzyuta, E. I.

    1974-01-01

    A transistorized spectrometric amplifier with a shaper is reported that selects the shape of the frequency characteristic of the amplifying channel for which the primary frequency spectrum of the signal will pass, but where the noise spectrum is limited to the maximum. A procedure is presented for selecting the shaping circuits and their inclusion principles.

  11. Extrahepatic bile duct ligation in broiler chickens: ultrastructural study of Ito cell

    Directory of Open Access Journals (Sweden)

    Ekowati Handharyani

    2004-12-01

    Full Text Available The Ito cell (fat-storing cell is a cell lying in perisinusoidal space of liver. The function of Ito cell is expanding from a site of fat-storing site to a center of extracellular matrix metabolism and mediator production in the liver. This study was performed in order to evaluate the Ito cells in cholestatic condition. The artificial cholestatic was conducted by ligation of extrahepatic bile ducts (bile duct ligation = BDL in broilers. The results showed that BDL induced bile congestion, fibrosis, proliferation of Ito cells and intrahepatic bile ductules. Immunohistochemistry demonstrated that Ito cells were scattered throughout the fibrotic areas, and larger in size with more extensive immunoreactivity than those in normal livers. Ultrastructural study demonstrated that Ito cells were closely associated with the production of extracellular collagen fibers. Ito cells actively react against hepatocytic injuries, especially in fibrogenesis of cholestatic livers.

  12. Impaired compensation to femoral artery ligation in diet-induced obese mice is primarily mediated via suppression of collateral growth by Nox2 and p47phox.

    Science.gov (United States)

    DiStasi, Matthew R; Mund, Julie A; Bohlen, H Glenn; Miller, Steven J; Ingram, David A; Dalsing, Michael C; Unthank, Joseph L

    2015-10-01

    The present study was undertaken to establish the role of NADPH oxidase (Nox) in impaired vascular compensation to arterial occlusion that occurs in the presence of risk factors associated with oxidative stress. Diet-induced obese (DIO) mice characterized by multiple comorbidities including diabetes and hyperlipidemia were used as a preclinical model. Arterial occlusion was induced by distal femoral artery ligation in lean and DIO mice. Proximal collateral arteries were identified as the site of major (∼70%) vascular resistance to calf perfusion by distal arterial pressures, which decreased from ∼80 to ∼30 mmHg with ligation in both lean and DIO mice. Two weeks after ligation, significant vascular compensation occurred in lean but not DIO mice as evidenced by increased perfusion (147 ± 48% vs. 49 ± 29%) and collateral diameter (151 ± 30% vs. 44 ± 17%). Vascular mRNA expression of p22(phox), Nox2, Nox4, and p47(phox) were all increased in DIO mice. Treatment of DIO mice with either apocynin or Nox2ds-tat or with whole body ablation of either Nox2 or p47(phox) ameliorated the impairment in both collateral growth and hindlimb perfusion. Multiparametric flow cytometry analysis demonstrated elevated levels of circulating monocytes in DIO mice without impaired mobilization and demargination after femoral artery ligation. These results establish collateral resistance as the major limitation to calf perfusion in this preclinical model, demonstrate than monocyte mobilization and demarginatin is not suppressed, implicate Nox2-p47(phox) interactions in the impairment of vascular compensation to arterial occlusion in DIO mice, and suggest that selective Nox component suppression/inhibition may be effective as either primary or adjuvant therapy for claudicants. Copyright © 2015 the American Physiological Society.

  13. Sequence-related amplified polymorphism (SRAP) markers: A potential resource for studies in plant molecular biology1

    Science.gov (United States)

    Robarts, Daniel W. H.; Wolfe, Andrea D.

    2014-01-01

    In the past few decades, many investigations in the field of plant biology have employed selectively neutral, multilocus, dominant markers such as inter-simple sequence repeat (ISSR), random-amplified polymorphic DNA (RAPD), and amplified fragment length polymorphism (AFLP) to address hypotheses at lower taxonomic levels. More recently, sequence-related amplified polymorphism (SRAP) markers have been developed, which are used to amplify coding regions of DNA with primers targeting open reading frames. These markers have proven to be robust and highly variable, on par with AFLP, and are attained through a significantly less technically demanding process. SRAP markers have been used primarily for agronomic and horticultural purposes, developing quantitative trait loci in advanced hybrids and assessing genetic diversity of large germplasm collections. Here, we suggest that SRAP markers should be employed for research addressing hypotheses in plant systematics, biogeography, conservation, ecology, and beyond. We provide an overview of the SRAP literature to date, review descriptive statistics of SRAP markers in a subset of 171 publications, and present relevant case studies to demonstrate the applicability of SRAP markers to the diverse field of plant biology. Results of these selected works indicate that SRAP markers have the potential to enhance the current suite of molecular tools in a diversity of fields by providing an easy-to-use, highly variable marker with inherent biological significance. PMID:25202637

  14. Sequence-related amplified polymorphism (SRAP) markers: A potential resource for studies in plant molecular biology(1.).

    Science.gov (United States)

    Robarts, Daniel W H; Wolfe, Andrea D

    2014-07-01

    In the past few decades, many investigations in the field of plant biology have employed selectively neutral, multilocus, dominant markers such as inter-simple sequence repeat (ISSR), random-amplified polymorphic DNA (RAPD), and amplified fragment length polymorphism (AFLP) to address hypotheses at lower taxonomic levels. More recently, sequence-related amplified polymorphism (SRAP) markers have been developed, which are used to amplify coding regions of DNA with primers targeting open reading frames. These markers have proven to be robust and highly variable, on par with AFLP, and are attained through a significantly less technically demanding process. SRAP markers have been used primarily for agronomic and horticultural purposes, developing quantitative trait loci in advanced hybrids and assessing genetic diversity of large germplasm collections. Here, we suggest that SRAP markers should be employed for research addressing hypotheses in plant systematics, biogeography, conservation, ecology, and beyond. We provide an overview of the SRAP literature to date, review descriptive statistics of SRAP markers in a subset of 171 publications, and present relevant case studies to demonstrate the applicability of SRAP markers to the diverse field of plant biology. Results of these selected works indicate that SRAP markers have the potential to enhance the current suite of molecular tools in a diversity of fields by providing an easy-to-use, highly variable marker with inherent biological significance.

  15. Multi-pass amplifier architecture for high power laser systems

    Science.gov (United States)

    Manes, Kenneth R; Spaeth, Mary L; Erlandson, Alvin C

    2014-04-01

    A main amplifier system includes a first reflector operable to receive input light through a first aperture and direct the input light along an optical path. The input light is characterized by a first polarization. The main amplifier system also includes a first polarizer operable to reflect light characterized by the first polarization state. The main amplifier system further includes a first and second set of amplifier modules. Each of the first and second set of amplifier modules includes an entrance window, a quarter wave plate, a plurality of amplifier slablets arrayed substantially parallel to each other, and an exit window. The main amplifier system additionally includes a set of mirrors operable to reflect light exiting the first set of amplifier modules to enter the second set of amplifier modules and a second polarizer operable to reflect light characterized by a second polarization state.

  16. Design of an 1800nm Raman amplifier

    DEFF Research Database (Denmark)

    Svane, Ask Sebastian; Rottwitt, Karsten

    2013-01-01

    We present the experimental results for a Raman amplifier that operates at 1810 nm and is pumped by a Raman fiber laser at 1680 nm. Both the pump laser and the Raman amplifier is polarization maintaining. A challenge when scaling Raman amplifiers to longer wavelengths is the increase...... in transmission loss, but also the reduction in the Raman gain coefficient as the amplifier wavelength is increased. Both polarization components of the Raman gain is characterized, initially for linearly co-polarized signal and pump, subsequently linearly polarized orthogonal signal and pump. The noise...

  17. Counting molecules in cell-free DNA and single cells RNA

    OpenAIRE

    Karlsson, Kasper

    2016-01-01

    The field of Molecular Biology got started in earnest with the discovery of the molecular structure of DNA. This lead to a surge of interest into the relationships between DNA, RNA and proteins, and to the development of fundamental tools for manipulating those substances, such as cutting, ligating, amplifying, visualizing and size-selecting DNA. With these tools at hand it was possible to begin sequencing DNA, a process that took a leap forward in 2005 with the advent of Next Generation Sequ...

  18. Remote Acquisition Amplifier For 50-Ohm Cable

    Science.gov (United States)

    Amador, Jose J.

    1995-01-01

    Buffer-amplifier unit designed to drive 50-Ohm cables up to 100 ft. (30 m) long, compensating for attenuation in cables and enabling remote operation of oscilloscopes. Variable resistor provides for adjustment of gain of amplifier, such that overall gain from input terminals of amplifier to output end of cable set to unity.

  19. A multiplex ligation detection assay for the characterization of Salmonella enterica strains

    NARCIS (Netherlands)

    Aarts, H.J.M.; Vos, P.; Larsson, J.T.; Hoek, van A.H.A.M.; Huehn, S.; Weijers, T.; Gronlund, H.A.; Malorny, B.

    2011-01-01

    A proof of principle of a multi-target assay for genotyping Salmonella has been developed targeting 62 genomic marker sequences of Salmonella related to pathogenicity. The assay is based on multiplex ligation detection reaction (LDR) followed by customized ArrayTube (R) microarray detection. The

  20. Streptococcus sanguinis meningitis following endoscopic ligation for oesophageal variceal haemorrhage.

    Science.gov (United States)

    Liu, Yu-Ting; Lin, Chin-Fu; Lee, Ya-Ling

    2013-05-01

    We report a case of acute purulent meningitis caused by Streptococcus sanguinis after endoscopic ligation for oesophageal variceal haemorrhage in a cirrhotic patient without preceding symptoms of meningitis. Initial treatment with flomoxef failed. The patient was cured after 20 days of intravenous penicillin G. This uncommon infection due to S. sanguinis adds to the long list of infectious complications among patients with oesophageal variceal haemorrhage.

  1. A Simple Suturing Technique for Laparoscopic Ligation of Vascular Pedicles

    Directory of Open Access Journals (Sweden)

    Keith A. Aqua

    1996-01-01

    Full Text Available We report on the performance of 348 adnexectomies and 35 uterine artery ligations for both benign and malignant disease using a simple laparoscopic suturing technique. Only 5-mm ports are required, and there was no morbidity directly associated with this approach. The procedure can be performed quickly, is relatively inexpensive, and allows hysterectomy and oophorectomy to be performed without bipolar electrocautery.

  2. Replication-Coupled PCNA Unloading by the Elg1 Complex Occurs Genome-wide and Requires Okazaki Fragment Ligation

    Directory of Open Access Journals (Sweden)

    Takashi Kubota

    2015-08-01

    Full Text Available The sliding clamp PCNA is a crucial component of the DNA replication machinery. Timely PCNA loading and unloading are central for genome integrity and must be strictly coordinated with other DNA processing steps during replication. Here, we show that the S. cerevisiae Elg1 replication factor C-like complex (Elg1-RLC unloads PCNA genome-wide following Okazaki fragment ligation. In the absence of Elg1, PCNA is retained on chromosomes in the wake of replication forks, rather than at specific sites. Degradation of the Okazaki fragment ligase Cdc9 leads to PCNA accumulation on chromatin, similar to the accumulation caused by lack of Elg1. We demonstrate that Okazaki fragment ligation is the critical prerequisite for PCNA unloading, since Chlorella virus DNA ligase can substitute for Cdc9 in yeast and simultaneously promotes PCNA unloading. Our results suggest that Elg1-RLC acts as a general PCNA unloader and is dependent upon DNA ligation during chromosome replication.

  3. Multiple excitation regenerative amplifier inertial confinement system

    International Nuclear Information System (INIS)

    George, V.E.; Haas, R.A.; Krupke, W.F.; Schlitt, L.G.

    1980-01-01

    The invention relates to apparatus and methods for producing high intensity laser radiation generation which is achieved through an optical amplifier-storage ring design. One or two synchronized, counterpropagating laser pulses are injected into a regenerative amplifier cavity and amplified by gain media which are pumped repetitively by electrical or optical means. The gain media excitation pulses are tailored to efficiently amplify the laser pulses during each transit. After the laser pulses have been amplified to the desired intensity level, they are either switched out of the cavity by some switch means, as for example an electro-optical device, for any well known laser end uses, or a target means may be injected into the regenerative amplifier cavity in such a way as to intercept simultaneously the counterpropagating laser pulses. One such well known end uses to which this invention is intended is for production of high density and temperature plasmas suitable for generating neutrons, ions and x-rays and for studying matter heated by high intensity laser radiation

  4. Spectral hole-burning and carrier-heating dynamics in quantum-dot amplifiers: Comparison with bulk amplifiers

    DEFF Research Database (Denmark)

    Borri, P.; Langbein, W.; Hvam, Jørn Märcher

    2001-01-01

    The ultrafast gain dynamics in an electrically pumped InAs/InGaAs/GaAs quantum-dot amplifier are measured at room temperature with femtosecond resolution, and compared with results on an InGaAsP bulk amplifier. The role of spectral hole burning and carrier heating in the recovery of the gain...

  5. Mass amplifying probe for sensitive fluorescence anisotropy detection of small molecules in complex biological samples.

    Science.gov (United States)

    Cui, Liang; Zou, Yuan; Lin, Ninghang; Zhu, Zhi; Jenkins, Gareth; Yang, Chaoyong James

    2012-07-03

    Fluorescence anisotropy (FA) is a reliable and excellent choice for fluorescence sensing. One of the key factors influencing the FA value for any molecule is the molar mass of the molecule being measured. As a result, the FA method with functional nucleic acid aptamers has been limited to macromolecules such as proteins and is generally not applicable for the analysis of small molecules because their molecular masses are relatively too small to produce observable FA value changes. We report here a molecular mass amplifying strategy to construct anisotropy aptamer probes for small molecules. The probe is designed in such a way that only when a target molecule binds to the probe does it activate its binding ability to an anisotropy amplifier (a high molecular mass molecule such as protein), thus significantly increasing the molecular mass and FA value of the probe/target complex. Specifically, a mass amplifying probe (MAP) consists of a targeting aptamer domain against a target molecule and molecular mass amplifying aptamer domain for the amplifier protein. The probe is initially rendered inactive by a small blocking strand partially complementary to both target aptamer and amplifier protein aptamer so that the mass amplifying aptamer domain would not bind to the amplifier protein unless the probe has been activated by the target. In this way, we prepared two probes that constitute a target (ATP and cocaine respectively) aptamer, a thrombin (as the mass amplifier) aptamer, and a fluorophore. Both probes worked well against their corresponding small molecule targets, and the detection limits for ATP and cocaine were 0.5 μM and 0.8 μM, respectively. More importantly, because FA is less affected by environmental interferences, ATP in cell media and cocaine in urine were directly detected without any tedious sample pretreatment. Our results established that our molecular mass amplifying strategy can be used to design aptamer probes for rapid, sensitive, and selective

  6. The OPTHER Project: Progress toward the THz Amplifier

    DEFF Research Database (Denmark)

    Paoloni, C; Brunetti, F; Di Carlo, A

    2011-01-01

    This paper describes the status of the OPTHER (OPtically driven TeraHertz AmplifiERs) project and progress toward the THz amplifier realization. This project represents a considerable advancement in the field of high frequency amplification. The design and realization of a THz amplifier within...... this project is a consolidation of efforts at the international level from the leading scientific and industrial European organizations working with vacuum electronics....

  7. Very broad bandwidth klystron amplifiers

    Science.gov (United States)

    Faillon, G.; Egloff, G.; Farvet, C.

    Large surveillance radars use transmitters at peak power levels of around one MW and average levels of a few kW, and possibly several tens of kW, in S band, or even C band. In general, the amplification stage of these transmitters is a microwave power tube, frequently a klystron. Although designers often turn to klystrons because of their good peak and average power capabilities, they still see them as narrow band amplifiers, undoubtedly because of their resonant cavities which, at first sight, would seem highly selective. But, with the progress of recent years, it has now become quite feasible to use these tubes in installations requiring bandwidths in excess of 10 - 12 percent, and even 15 percent, at 1 MW peak for example, in S-band.

  8. Biomechanical characteristics of self-ligating brackets in a vertically displaced canine model: a finite element analysis.

    Science.gov (United States)

    Kim, S-J; Kwon, Y-H; Hwang, C-J

    2016-05-01

    The objective of this study was to compare the biomechanical characteristics between two types of self-ligating brackets and conventional metal brackets using finite element analysis of a vertically displaced canine model focusing on the desired force on the canine and undesirable forces on adjacent teeth. Three-dimensional finite element models of the maxillary dentition with 1-mm, 2-mm, and 3-mm vertically displaced canines were constructed. Two different self-ligating brackets (In-Ovation C and Smart clip) and a conventional metal bracket (Micro-arch) were modeled. After a 0.016-inch NiTi (0.40 mm, round) wire was engaged, the displacement of each tooth was calculated using x-, y-, and z-coordinates, and the tensile and compressive stresses were calculated. The extrusion and maximal tensile stress of the canine differed little between the three brackets, but the intrusion and minimal compressive stress values of the adjacent teeth differed considerably and were highest in the Smart clip and least in the In-Ovation C. The extrusion and maximal tensile stress of the canine in the 3-mm displacement model was less than that in the 2-mm displacement model, and the intrusion and minimal compressive stress of the adjacent teeth increased with the degree of displacement. Self-ligating brackets were not superior to conventional brackets in leveling a vertically displaced canine. A continuous arch wire may not be recommended for leveling of severely displaced canines whether using self-ligating or conventional brackets. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Spectroscopic amplifier for pin diode

    International Nuclear Information System (INIS)

    Alonso M, M. S.; Hernandez D, V. M.; Vega C, H. R.

    2014-10-01

    The photodiode remains the basic choice for the photo-detection and is widely used in optical communications, medical diagnostics and field of corpuscular radiation. In detecting radiation it has been used for monitoring radon and its progeny and inexpensive spectrometric systems. The development of a spectroscopic amplifier for Pin diode is presented which has the following characteristics: canceler Pole-Zero (P/Z) with a time constant of 8 μs; constant gain of 57, suitable for the acquisition system; 4th integrator Gaussian order to waveform change of exponential input to semi-Gaussian output and finally a stage of baseline restorer which prevents Dc signal contribution to the next stage. The operational amplifier used is the TLE2074 of BiFET technology of Texas Instruments with 10 MHz bandwidth, 25 V/μs of slew rate and a noise floor of 17 nv/(Hz)1/2. The integrated circuit has 4 operational amplifiers and in is contained the total of spectroscopic amplifier that is the goal of electronic design. The results show like the exponential input signal is converted to semi-Gaussian, modifying only the amplitude according to the specifications in the design. The total system is formed by the detector, which is the Pin diode, a sensitive preamplifier to the load, the spectroscopic amplifier that is what is presented and finally a pulse height analyzer (Mca) which is where the spectrum is shown. (Author)

  10. Dimensional accuracy of ceramic self-ligating brackets and estimates of theoretical torsional play.

    Science.gov (United States)

    Lee, Youngran; Lee, Dong-Yul; Kim, Yoon-Ji R

    2016-09-01

    To ascertain the dimensional accuracies of some commonly used ceramic self-ligation brackets and the amount of torsional play in various bracket-archwire combinations. Four types of 0.022-inch slot ceramic self-ligating brackets (upper right central incisor), three types of 0.018-inch ceramic self-ligating brackets (upper right central incisor), and three types of rectangular archwires (0.016 × 0.022-inch beta-titanium [TMA] (Ormco, Orange, Calif), 0.016 × 0.022-inch stainless steel [SS] (Ortho Technology, Tampa, Fla), and 0.019 × 0.025-inch SS (Ortho Technology)) were measured using a stereomicroscope to determine slot widths and wire cross-sectional dimensions. The mean acquired dimensions of the brackets and wires were applied to an equation devised by Meling to estimate torsional play angle (γ). In all bracket systems, the slot tops were significantly wider than the slot bases (P brackets, and Clippy-Cs (Tomy, Futaba, Fukushima, Japan) among the 0.018-inch brackets. The Damon Clear (Ormco) bracket had the smallest dimensional error (0.542%), whereas the 0.022-inch Empower Clear (American Orthodontics, Sheboygan, Wis) bracket had the largest (3.585%). The largest amount of theoretical play is observed using the Empower Clear (American Orthodontics) 0.022-inch bracket combined with the 0.016 × 0.022-inch TMA wire (Ormco), whereas the least amount occurs using the 0.018 Clippy-C (Tomy) combined with 0.016 × 0.022-inch SS wire (Ortho Technology).

  11. Actual versus theoretical torsional play in conventional and self-ligating bracket systems

    DEFF Research Database (Denmark)

    Dalstra, Michel; Eriksen, Henrik; Bergamini, Chiara

    2015-01-01

    Abstract Objective: The aim of this study was to assess the amount of torsional play in 32 commercially available self-ligating and conventional 0·018-inch and 0·022-inch bracket systems in relation to 0·017×0·022-inch and 0·019×0·025-inch stainless steel wires, respectively, and compare...... the results with the theoretical amount of play for the given bracket/wire combinations. Methods: Torque moments were measured in a mechanical force testing system by twisting straight pieces of stainless steel wire seated in the bracket slot in increments of 0·5° until a full torsional expression...... and the inability of self-ligation brackets to press the archwire into the bottom of the slot. In conventional brackets, the initial torque moment is generated by the steel ligatures pressing the arch wire against the bottom of the slot. The oversize of the slot is thus less critical in relation to the conventional...

  12. TLR9 ligation in pancreatic stellate cells promotes tumorigenesis.

    Science.gov (United States)

    Zambirinis, Constantinos P; Levie, Elliot; Nguy, Susanna; Avanzi, Antonina; Barilla, Rocky; Xu, Yijie; Seifert, Lena; Daley, Donnele; Greco, Stephanie H; Deutsch, Michael; Jonnadula, Saikiran; Torres-Hernandez, Alejandro; Tippens, Daniel; Pushalkar, Smruti; Eisenthal, Andrew; Saxena, Deepak; Ahn, Jiyoung; Hajdu, Cristina; Engle, Dannielle D; Tuveson, David; Miller, George

    2015-11-16

    Modulation of Toll-like receptor (TLR) signaling can have protective or protumorigenic effects on oncogenesis depending on the cancer subtype and on specific inflammatory elements within the tumor milieu. We found that TLR9 is widely expressed early during the course of pancreatic transformation and that TLR9 ligands are ubiquitous within the tumor microenvironment. TLR9 ligation markedly accelerates oncogenesis, whereas TLR9 deletion is protective. We show that TLR9 activation has distinct effects on the epithelial, inflammatory, and fibrogenic cellular subsets in pancreatic carcinoma and plays a central role in cross talk between these compartments. Specifically, TLR9 activation can induce proinflammatory signaling in transformed epithelial cells, but does not elicit oncogene expression or cancer cell proliferation. Conversely, TLR9 ligation induces pancreatic stellate cells (PSCs) to become fibrogenic and secrete chemokines that promote epithelial cell proliferation. TLR9-activated PSCs mediate their protumorigenic effects on the epithelial compartment via CCL11. Additionally, TLR9 has immune-suppressive effects in the tumor microenvironment (TME) via induction of regulatory T cell recruitment and myeloid-derived suppressor cell proliferation. Collectively, our work shows that TLR9 has protumorigenic effects in pancreatic carcinoma which are distinct from its influence in extrapancreatic malignancies and from the mechanistic effects of other TLRs on pancreatic oncogenesis. © 2015 Zambirinis et al.

  13. Chemical Ligation: A Versatile Method for Nucleoside Modification with Boron Clusters

    Czech Academy of Sciences Publication Activity Database

    Wojtczak, B. A.; Andrysiak, A.; Grüner, Bohumír; Lesnikowski, Z. J.

    -, č. 14 (2008), s. 10675-10682 ISSN 0947-6539 R&D Projects: GA MŠk LC523 Grant - others:MSHE(PL) N405 051 32/3592; MSHE(PL) K152/H03/2007/10 Institutional research plan: CEZ:AV0Z40320502 Keywords : alkynes * azides * chemical ligation Subject RIV: CA - Inorganic Chemistry Impact factor: 5.454, year: 2008

  14. Quantum electronics maser amplifiers and oscillators

    CERN Document Server

    Fain, V M; Sanders, J H

    2013-01-01

    Quantum Electronics, Volume 2: Maser Amplifiers and Oscillators deals with the experimental and theoretical aspects of maser amplifiers and oscillators which are based on the principles of quantum electronics. It shows how the concepts and equations used in quantum electronics follow from the basic principles of theoretical physics.Comprised of three chapters, this volume begins with a discussion on the elements of the theory of quantum oscillators and amplifiers working in the microwave region, along with the practical achievements in this field. Attention is paid to two-level paramagnetic ma

  15. Outcome of band ligation in oesophageal varices

    International Nuclear Information System (INIS)

    Abbasi, A.; Bhutto, A.R.; Bhatti, K.I.; Mahmood, K.; Lal, K.

    2013-01-01

    Objective: To find out the outcome og band ligation of oesophageal varices in decompensated chronic liver disease patients. Methods: The quasi experimental study was conducted at the Jinnah Postgraduate Medical Centre, Karachi, and Civil Hospital, Karachi, unit from September 2007 to August 2011. Subjects were eligible if they had a diagnosis of cirrhosis based on history, physical examination, biochemical parameters and liver biopsy in some cases. Patients with advanced cirrhosis (Child-Pugh class C), antibodies against human immunodeficiency virus, hepatocellular carcinoma, portal vein thrombosis evident on ultrasonography, parenteral drug addiction, current alcohol abuse, previous or current treatment with β-blockers were excluded from the study. All patients were asked about alcohol intake and tested to determine the cause of liver cirrhosis. Tests for other causes of cirrhosis were carried out only if there was a suggestive clue. All patients under-went upper gastrointestinal endoscopy after consent. SPSS 15 was used for statistical analysis. Results: The age of the 173 patients who met the inclusion criteria ranged from 15 to 85 years, with a mean of 48.39+-13.38 years. There were 112 (64.7%) males. High-grade varices were seen in 130 (75.1%) patients, while low-grade varices were observed in 43 (24.9%) on first endoscopy. At initial endoscopy, 111 (64.2%) patients had portal hypertensive gastropathy. The patients were followed up for a mean period of 5.20+-2.67 months. Variceal obliteration was achieved in 138 (79.8%), while 33 (19.1%) cases developed re-bleeding. Mean number of endoscopy sessions for these patients were 2.28+-.918 with a maximum of 4. Conclusion: Band ligation eradicated oesophageal varices with less complications and a lower re-bleeding rate, but at the same time eradication was associated with more frequent development of portal hypertensive gastropathy. (author)

  16. FGFR antagonist induces protective autophagy in FGFR1-amplified breast cancer cell

    International Nuclear Information System (INIS)

    Chen, Yi; Xie, Xiaoyan; Li, Xinyi; Wang, Peiqi; Jing, Qian; Yue, Jiaqi; Liu, Yang; Cheng, Zhong; Li, Jingyi; Song, Haixing; Li, Guoyu; Liu, Rui; Wang, Jinhui

    2016-01-01

    Breast cancer, representing approximately 30% of all gynecological cancer cases diagnosed yearly, is a leading cause of cancer-related mortality for women. Amplification of FGFR1 is frequently observed in breast cancers and is associated with poor prognosis. Though FGFRs have long been considered as anti-cancer drug targets, and a cluster of FGFR antagonists are currently under clinical trials, the precise cellular responses under the treatment of FGFR antagonists remains unclear. Here, we show that PD166866, an FGFR1-selective inhibitor, inhibits proliferation and triggers anoikis in FGFR1-amplified breast cancer cell lines. Notably, we demonstrate that PD166866 induces autophagy in FGFR1-amplified breast cancer cell lines, while blockage of autophagy by Atg5 knockdown further enhances the anti-proliferative activities of PD166866. Moreover, mechanistic study reveals that PD166866 induces autophagy through repressing Akt/mTOR signaling pathway. Together, the present study provides new insights into the molecular mechanisms underlying the anti-tumor activities of FGFR antagonists, and may further assist the FGFRs-based drug discovery. -- Highlights: •FGFR1 antagonist inhibits cell viability in FGFR1-amplified breast cancer cells. •FGFR1 antagonist induces autophagy in FGFR1-amplified breast cancer cells. •FGFR1 antagonist-induced autophagy is protective. •FGFR1 antagonist induces autophagy by inhibiting Akt/mTOR pathway.

  17. FGFR antagonist induces protective autophagy in FGFR1-amplified breast cancer cell

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yi [The School of Biomedical Sciences, Chengdu Medical College, Chengdu 610083 (China); Department of Gastrointestinal Surgery, West China Hospital, Sichuan University, Chengdu (China); Xie, Xiaoyan; Li, Xinyi; Wang, Peiqi [State Key Laboratory of Oral Diseases, West China College of Stomatology, Sichuan University (China); Jing, Qian; Yue, Jiaqi; Liu, Yang [The School of Biomedical Sciences, Chengdu Medical College, Chengdu 610083 (China); Cheng, Zhong [Department of Gastrointestinal Surgery, West China Hospital, Sichuan University, Chengdu (China); Li, Jingyi, E-mail: li--jingyi@hotmail.com [The School of Biomedical Sciences, Chengdu Medical College, Chengdu 610083 (China); Song, Haixing [The School of Biomedical Sciences, Chengdu Medical College, Chengdu 610083 (China); Li, Guoyu, E-mail: liguoyulisa@163.com [School of Pharmacy, Shihezi University, Shihezi 832003 (China); Liu, Rui, E-mail: liurui_scu@hotmail.com [State Key Laboratory of Oral Diseases, West China College of Stomatology, Sichuan University (China); Wang, Jinhui [School of Pharmacy, Shihezi University, Shihezi 832003 (China)

    2016-05-20

    Breast cancer, representing approximately 30% of all gynecological cancer cases diagnosed yearly, is a leading cause of cancer-related mortality for women. Amplification of FGFR1 is frequently observed in breast cancers and is associated with poor prognosis. Though FGFRs have long been considered as anti-cancer drug targets, and a cluster of FGFR antagonists are currently under clinical trials, the precise cellular responses under the treatment of FGFR antagonists remains unclear. Here, we show that PD166866, an FGFR1-selective inhibitor, inhibits proliferation and triggers anoikis in FGFR1-amplified breast cancer cell lines. Notably, we demonstrate that PD166866 induces autophagy in FGFR1-amplified breast cancer cell lines, while blockage of autophagy by Atg5 knockdown further enhances the anti-proliferative activities of PD166866. Moreover, mechanistic study reveals that PD166866 induces autophagy through repressing Akt/mTOR signaling pathway. Together, the present study provides new insights into the molecular mechanisms underlying the anti-tumor activities of FGFR antagonists, and may further assist the FGFRs-based drug discovery. -- Highlights: •FGFR1 antagonist inhibits cell viability in FGFR1-amplified breast cancer cells. •FGFR1 antagonist induces autophagy in FGFR1-amplified breast cancer cells. •FGFR1 antagonist-induced autophagy is protective. •FGFR1 antagonist induces autophagy by inhibiting Akt/mTOR pathway.

  18. Alignment efficiency of standard versus tandem wire mechanics using conventional and self-ligating brackets: A pilot study

    Directory of Open Access Journals (Sweden)

    Prarthana Bhardwaj

    2017-01-01

    Full Text Available Objective: The objective of this study is to evaluate the clinical efficiency of 0.018″/0.022″ slot self-ligating (SL bracket system (standard and tandem mechanics in terms of rate of alignment by comparing it with a 0.022″ slot conventional ligating appliance system (MBT. Settings and Sample Population: The Department of Orthodontics. Materials and Methods: The pilot study was carried out using randomized controlled trial design. Forty patients having Little's irregularity index (II of 6–15 mm, treated by all first premolars extractions, were randomly allocated to 0.022″ slot conventional ligating bracket system, 0.018″ slot SL bracket system, 0.018″ slot SL bracket system (tandem archwires, 0.022″ slot SL bracket system, and 0.022″ slot SL bracket system (tandem archwires. The rate of alignment for each bracket system was measured from the difference in the II of serial casts taken at pretreatment and at the end of alignment, divided by the number of days between the two measurements. A one-way ANOVA model with post hoc Bonferroni multiple comparison procedures was used to identify intergroup differences. Results: The mean value of alignment efficiency was not found to be statistically significant in any of the five groups using digital models (P = 0.104. Conclusions: Alignment efficiency was not different between SL versus conventional ligating group, the 0.018″ slot versus 0.022″ slot and tandem versus standard mechanics.

  19. Class-E Amplifier Design Improvements for GSM Frequencies

    Directory of Open Access Journals (Sweden)

    Z. Nadir

    2011-06-01

    Full Text Available Efficient power amplifiers are essential in portable battery-operated systems such as mobile phones. Also, the power amplifier (PA is the most power-consuming building block in the transmitter of a portable system. This paper investigates how the efficiency of the power amplifier (which is beneficial for multiple applications in communcation sector can be improved by increasing the efficiency of switching mode class E power amplifiers for frequencies of 900 MHz and 1800 MHz. The paper tackles modeling, design improvements and verification through simulation for higher efficiencies. This is the continuation of previous work by the authors. These nonlinear power amplifiers can only amplify constant-envelope RF signals without introducing significant distortion. Mobile systems such as Advanced Mobile Phone System (AMPS and Global System for Mobile communications (GSM use modulation schemes which generate constant amplitude RF outputs in order to use efficient but nonlinear power amplifiers. Improvements in designs are suggested and higher efficiencies are achieved, to the tune of 67.1% (for 900 MHz and 67.0% (1800 MHz.

  20. Comparison of effectiveness and cost of patent ductus arteriosus device occlusion versus surgical ligation of patent ductus arteriosus.

    Science.gov (United States)

    Zulqarnain, Arif; Younas, Muhammad; Waqar, Tariq; Beg, Ahsan; Asma, Touseef; Baig, Mirza Ahmad Raza

    2016-01-01

    Comparison of effectiveness and cost of transcatheter occlusion of patent ductus arteriosus (PDA) with surgical ligation of PDA. This retrospective comparative study was conducted in the pediatric cardiology department of Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Data of 250 patients who underwent patent ductus arteriosus (PDA) closure either surgical or trans-catheter closure using SHSMA Occluder having weight >5 kg from April 2012 to October 2015 were included in this study. SPSS version 20 was used for data analysis. Quantitative variables were compared using independent sample t-test. Chi-square test and fishers exact was used for qualitative variables. P-value <0.05 was considered statistically significant. There were one hundred and twenty (120) patients who underwent transcatheter occlusion of PDA using SHSMA occluder (PDA Device Group) and one hundred and thirty (130) patients who underwent surgical ligation of PDA (Surgical Group). Incidence of residual shunting was two (1.5%) in surgical group and 0 (0.0%) in PDA Device group for one month follow up period. There were 4 (3.1%) major complications in surgical group. The rate of blood transfusions were high in surgical group (p-value 0.04). Hospital stay time was significantly less in PDA Device group (P-value <0.001). Total procedural cost was 110695+1054 Pakistani rupees in PDA Device group and 92414+3512 in surgical group (p-value <0.001). The cost of PDA device closure was 16.52% higher than the surgical ligation of PDA. There was no operative mortality. The transcatheter closure of PDA is an effective and less invasive method as compared to the surgical ligation. There is a lower rate of complications and the cost is not much high as compared to surgical PDA ligation.

  1. A Programmable Biopotential Aquisition Front-end with a Resistance-free Current-balancing Instrumentation Amplifier

    Directory of Open Access Journals (Sweden)

    FARAGO, P.

    2018-05-01

    Full Text Available The development of wearable biomedical equipment benefits from low-power and low-voltage circuit techniques for reduced battery size and battery, or even battery-less, operation. This paper proposes a fully-differential low-power resistance-free programmable instrumentation amplifier for the analog front-end of biopotential monitoring systems. The proposed instrumentation amplifier implements the current balancing technique. Low power consumption is achieved with subthreshold biasing. To reduce chip area and enable integration, passive resistances have been replaced with active equivalents. Accordingly, the instrumentation amplifier gain is expressed as the ratio of two transconductance values. The proposed instrumentation amplifier exhibits two degrees of freedom: one to set the desired range and the other for fine-tuning of the voltage gain. The proposed IA is employed in a programmable biopotential acquisition front-end. The programmable frequency-selective behavior is achieved by having the lower cutoff frequency of a Gm-C Tow-Thomas biquad varied in a constant-C tuning approach. The proposed solutions and the programmability of the operation parameters to the specifications of particular bio-medical signals are validated on a 350nm CMOS process.

  2. Amplified OTDR Systems for Multipoint Corrosion Monitoring

    Science.gov (United States)

    Nascimento, Jehan F.; Silva, Marcionilo J.; Coêlho, Isnaldo J. S.; Cipriano, Eliel; Martins-Filho, Joaquim F.

    2012-01-01

    We present two configurations of an amplified fiber-optic-based corrosion sensor using the optical time domain reflectometry (OTDR) technique as the interrogation method. The sensor system is multipoint, self-referenced, has no moving parts and can measure the corrosion rate several kilometers away from the OTDR equipment. The first OTDR monitoring system employs a remotely pumped in-line EDFA and it is used to evaluate the increase in system reach compared to a non-amplified configuration. The other amplified monitoring system uses an EDFA in booster configuration and we perform corrosion measurements and evaluations of system sensitivity to amplifier gain variations. Our experimental results obtained under controlled laboratory conditions show the advantages of the amplified system in terms of longer system reach with better spatial resolution, and also that the corrosion measurements obtained from our system are not sensitive to 3 dB gain variations. PMID:22737017

  3. Bandwidth tunable amplifier for recording biopotential signals.

    Science.gov (United States)

    Hwang, Sungkil; Aninakwa, Kofi; Sonkusale, Sameer

    2010-01-01

    This paper presents a low noise, low power, bandwidth tunable amplifier for bio-potential signal recording applications. By employing depletion-mode pMOS transistor in diode configuration as a tunable sub pA current source to adjust the resistivity of MOS-Bipolar pseudo-resistor, the bandwidth is adjusted without any need for a separate band-pass filter stage. For high CMRR, PSRR and dynamic range, a fully differential structure is used in the design of the amplifier. The amplifier achieves a midband gain of 39.8dB with a tunable high-pass cutoff frequency ranging from 0.1Hz to 300Hz. The amplifier is fabricated in 0.18εm CMOS process and occupies 0.14mm(2) of chip area. A three electrode ECG measurement is performed using the proposed amplifier to show its feasibility for low power, compact wearable ECG monitoring application.

  4. Efficacy of carvedilol versus propranolol versus variceal band ligation for primary prevention of variceal bleeding.

    Science.gov (United States)

    Abd ElRahim, Ayman Yosry; Fouad, Rabab; Khairy, Marwa; Elsharkawy, Aisha; Fathalah, Waleed; Khatamish, Haytham; Khorshid, Omayma; Moussa, Mona; Seyam, Moataz

    2018-01-01

    Band ligation and propranolol are the current therapies for primary prevention of variceal bleeding. Carvedilol is a rising nonselective beta-blocker used for reducing portal pressure with favorable outcome. The aim of this study to assess the efficacy of carvedilol, propranolol, and band ligation for primary prevention of variceal bleeding based on the effect of each regimen on progression of Child score and portal hypertensive gastropathy after 1 year. The study included 264 cirrhotic patients with medium/large-sized varices who were candidates for primary prophylaxis of variceal bleeding. Patients were randomly divided into three groups: group I: band ligation; group II: propranolol; group III: carvedilol. Group I showed higher success rate of 75 %, followed by group III with 70.2 % and group II with 65.2 %. Risk of bleeding was comparable between the three groups, with group II carrying the highest rate of complications (34.7 %) followed by group III (14.2 %) and finally group I (5.7 %). After 1 year of follow-up, Child score did not improve in any of the studied groups, while portal hypertensive gastropathy significantly increased in group I but decreased in groups II and III. Band ligation is the best treatment option for primary prevention of variceal bleeding with minimal complications. Carvedilol is a good pharmaceutical alternative medicine to propranolol with lesser side-effects. Progress of liver disease as represented by Child score is not affected by any of the primary variceal prophylactic regimens, although medical treatment reduces portal hypertensive gastropathy. Choice of treatment depends on patient will, compliance with treatment, and endoscopist competence.

  5. Fluorogenic dansyl-ligated gold nanoparticles for the detection of sulfur mustard by displacement assay.

    Science.gov (United States)

    Knighton, Richard C; Sambrook, Mark R; Vincent, Jack C; Smith, Simon A; Serpell, Christopher J; Cookson, James; Vickers, Matthew S; Beer, Paul D

    2013-03-21

    The dansyl fluorophore ligated to gold nanoparticles via imidazole and amine groups affords conjugates capable of detecting micromolar concentrations of the chemical warfare agent sulfur mustard by a fluorescence switching 'ON' displacement assay.

  6. Outage performance of opportunistic two-way amplify-and-forward relaying with outdated channel state information

    KAUST Repository

    Hwang, Kyusung; Ju, Minchul; Alouini, Mohamed-Slim

    2013-01-01

    In this paper, we study the outage performance of an amplify-and-forward (AF)-based two-way relaying (TWR) system with multiple relays where a single relay selection is performed based on outdated channel state information (CSI). Specifically, we

  7. BROADBAND TRAVELLING WAVE SEMICONDUCTOR OPTICAL AMPLIFIER

    DEFF Research Database (Denmark)

    2010-01-01

    Broadband travelling wave semiconductor optical amplifier (100, 200, 300, 400, 800) for amplification of light, wherein the amplifier (100, 200, 300, 400, 800) comprises a waveguide region (101, 201, 301, 401, 801) for providing confinement of the light in transverse directions and adapted...

  8. A modular positive feedback-based gene amplifier

    Directory of Open Access Journals (Sweden)

    Bhalerao Kaustubh D

    2010-02-01

    Full Text Available Abstract Background Positive feedback is a common mechanism used in the regulation of many gene circuits as it can amplify the response to inducers and also generate binary outputs and hysteresis. In the context of electrical circuit design, positive feedback is often considered in the design of amplifiers. Similar approaches, therefore, may be used for the design of amplifiers in synthetic gene circuits with applications, for example, in cell-based sensors. Results We developed a modular positive feedback circuit that can function as a genetic signal amplifier, heightening the sensitivity to inducer signals as well as increasing maximum expression levels without the need for an external cofactor. The design utilizes a constitutively active, autoinducer-independent variant of the quorum-sensing regulator LuxR. We experimentally tested the ability of the positive feedback module to separately amplify the output of a one-component tetracycline sensor and a two-component aspartate sensor. In each case, the positive feedback module amplified the response to the respective inducers, both with regards to the dynamic range and sensitivity. Conclusions The advantage of our design is that the actual feedback mechanism depends only on a single gene and does not require any other modulation. Furthermore, this circuit can amplify any transcriptional signal, not just one encoded within the circuit or tuned by an external inducer. As our design is modular, it can potentially be used as a component in the design of more complex synthetic gene circuits.

  9. Realization of OFCC based Transimpedance Mode Instrumentation Amplifier

    Directory of Open Access Journals (Sweden)

    Neeta Pandey

    2016-01-01

    Full Text Available The paper presents an instrumentation amplifier suitable for amplifying the current source transducer signals. It provides a voltage output. It has a high gain, common mode rejection ratio and gain independent bandwidth. It uses three Operational Floating Current Conveyors (OFCCs and four resistors. The effect of nonidealities of OFCC on performance of proposed transimpedance instrumentation amplifier (TIA is also analyzed. The proposal has been verified through SPICE simulations using CMOS based schematicThe paper presents an instrumentation amplifier suitable for amplifying the current source transducer signals. It provides a voltage output. It has a high gain, common mode rejection ratio and gain independent bandwidth. It uses three operational floating current conveyors (OFCCs and four resistors. The effect of nonidealities of OFCC on performance of proposed transimpedance instrumentation amplifier (TIA is also analyzed. The proposal has been verified through SPICE simulations using CMOS based schematic.

  10. Quantum-Limited Directional Amplifiers with Optomechanics

    Science.gov (United States)

    Malz, Daniel; Tóth, László D.; Bernier, Nathan R.; Feofanov, Alexey K.; Kippenberg, Tobias J.; Nunnenkamp, Andreas

    2018-01-01

    Directional amplifiers are an important resource in quantum-information processing, as they protect sensitive quantum systems from excess noise. Here, we propose an implementation of phase-preserving and phase-sensitive directional amplifiers for microwave signals in an electromechanical setup comprising two microwave cavities and two mechanical resonators. We show that both can reach their respective quantum limits on added noise. In the reverse direction, they emit thermal noise stemming from the mechanical resonators; we discuss how this noise can be suppressed, a crucial aspect for technological applications. The isolation bandwidth in both is of the order of the mechanical linewidth divided by the amplitude gain. We derive the bandwidth and gain-bandwidth product for both and find that the phase-sensitive amplifier has an unlimited gain-bandwidth product. Our study represents an important step toward flexible, on-chip integrated nonreciprocal amplifiers of microwave signals.

  11. A new resorbable device for ligation of blood vessels - A pilot study

    Directory of Open Access Journals (Sweden)

    Borg Niklas

    2011-07-01

    Full Text Available Abstract Background During surgery, controlled haemostasis to prevent blood loss is vital for a successful outcome. It can be difficult to ligate vessels located deep in the abdomen. A device that is easy to use and enables secure ligatures could be beneficial. Cable ties made of nylon have been used for ligation but the non-resorbable material caused tissue reactions. The objective of this study was to use a resorbable material to construct a device with a self-locking mechanism and to test its mechanical strength and ligation efficiency. Methods The device was manufactured by injection moulding of polydioxanone, a resorbable polymer used for suture materials. Polydioxanone with inherent viscosities of 1.9 dL/g and 1.3 dL/g were tested. The device consisted of a perforated flexible band which could be pulled through a case with a locking mechanism. After a first version of the device had been tested, some improvements were made. The locking case was downsized, corners were rounded off, the band was made thicker and the mould was redesigned to produce longer devices. Tensile tests were performed with the second version. The first version of the device was used to ligate the ovarian pedicle in a euthanized dog and to test echogenicity of the device with ultrasound. Compression of vessels of the ovarian pedicle was examined by histology. Both versions of the device were tested for haemostasis of and tissue grip on renal arteries in six anaesthetised pigs. Results The tensile strength of the flexible band of the devices with inherent viscosity of 1.9 dL/g was 50.1 ± 5.5 N (range 35.2-62.9 N, n = 11 and the devices with inherent viscosity of 1.3 dL/g had a tensile strength of 39.8 ± 8.1 N (range 18.6-54.2 N, n = 11. Injection moulding of the polymer with lower inherent viscosity resulted in a longer flow distance. Both versions of the device had an effective tissue grip and complete haemostasis of renal arteries was verified. The device attached

  12. Evaluation of force released by deflection of orthodontic wires in conventional and self-ligating brackets.

    Science.gov (United States)

    Higa, Rodrigo Hitoshi; Semenara, Nayara Thiago; Henriques, José Fernando Castanha; Janson, Guilherme; Sathler, Renata; Fernandes, Thais Maria Freire

    2016-01-01

    The aim of the study was to evaluate deflection forces of rectangular orthodontic wires in conventional (MorelliTM), active (In-Ovation RTM) and passive (Damon 3MXTM) self-ligating brackets. Two brands of stainless steel and nickel-titanium (NiTi) wires (MorelliTM and GACTM), in addition to OrmcoTM copper-nickel-titanium wires were used. Specimens were assembled in a clinical simulation device especially designed for this study and tested in an Instron universal testing machine. For the testing procedures, an acrylic structure representative of the maxillary right central incisor was lingually moved in activations of 0 to 1 mm, with readings of the force released by deflection in unloading of 0.5, 0.8 and 1 mm at a constant speed of 2 mm/min. Inter-bracket forces with stainless steel, NiTi and CuNiTi were individually compared by two-way ANOVA, followed by Tukey's tests. Results showed that there were lower forces in conventional brackets, followed by active and passive self-ligating brackets. Within the brands, only for NiTi wires, the MorelliTM brand presented higher forces than GACTM wires. Bracket systems provide different degrees of deflection force, with self-ligating brackets showing the highest forces.

  13. A multiplex ligation detection assay for the characterization of Salmonella enterica strains

    DEFF Research Database (Denmark)

    Aarts, Henk J.M.; Vos, Pieter; Larsson, Jonas T.

    2011-01-01

    A proof of principle of a multi-target assay for genotyping Salmonella has been developed targeting 62 genomic marker sequences of Salmonella related to pathogenicity. The assay is based on multiplex ligation detection reaction (LDR) followed by customized ArrayTube® microarray detection. The fea...... assessors that support bio-traceability models....

  14. Intercellular adhesion molecule-1/LFA-1 ligation favors human Th1 development

    NARCIS (Netherlands)

    Smits, Hermelijn H.; de Jong, Esther C.; Schuitemaker, Joost H. N.; Geijtenbeek, Theo B. H.; van Kooyk, Yvette; Kapsenberg, Martien L.; Wierenga, Eddy A.

    2002-01-01

    Th cell polarization toward Th1 or Th2 cells is strongly driven by exogenous cytokines, in particular IL-12 or IL-4, if present during activation by Ag-presenting dendritic cells (DC). However, additional Th cell polarizing mechanisms are induced by the ligation of cell surface molecules on DC and

  15. Difficulty with cuff deflation of reinforced tracheal tube caused by inflation line occlusion with silk thread ligation and fixation.

    Science.gov (United States)

    Gotoh, Sayoko; Sugiyama, Daisuke; Imai, Eriko; Kawamata, Mikito

    2015-03-05

    A reinforced tracheal tube, ligated with silk threads, was inserted into a tracheostomy orifice and fixed to the skin. The cuff inflation line of the reinforced tracheal tube became occluded. Reinforced 'armoured' tracheal tubes have a spiral of wire embedded into the wall of the tube to give strength and flexibility, and may be sharply bent without compromising the tube lumen. The tracheal cuff attached to the tube is inflated by injecting air through a narrow-diameter tube welded to the outside of the tracheal tube. When a reinforced tracheal tube is ligated and fixed with silk threads, it should be confirmed whether the tracheal tube cuff can be deflated and inflated after fixation. Moreover, because occlusion can be eliminated by removing all silk threads used to ligate a tracheal tube, they should be removed before extubation. 2015 BMJ Publishing Group Ltd.

  16. Multifunction Voltage-Mode Filter Using Single Voltage Differencing Differential Difference Amplifier

    Directory of Open Access Journals (Sweden)

    Chaichana Amornchai

    2017-01-01

    Full Text Available In this paper, a voltage mode multifunction filter based on single voltage differencing differential difference amplifier (VDDDA is presented. The proposed filter with three input voltages and single output voltage is constructed with single VDDDA, two capacitors and two resistors. Its quality factor can be adjusted without affecting natural frequency. Also, the natural frequency can be electronically tuned via adjusting of bias current. The filter can offer five output responses, high-pas (HP, band-pass (BP, band-reject (BR, low-pass (LP and all-ass (AP functions in the same circuit topology. The output response can be selected by choosing the suitable input voltage without the component matching condition and the requirement of additional double gain voltage amplifier. PSpice simulation results to confirm an operation of the proposed filter correspond to the theory.

  17. Integrated wide-band low-background amplifiers

    International Nuclear Information System (INIS)

    Il'yushchenko, I.I.

    1980-01-01

    Ways of increasing stability and reproduction of characteristics of wide-band integral amplifiers that would to the least extent increase their background noises, are discussed. Considered are some certain flowsheets of integral wide-band amplifiers with low background noise of foreign production which differ from one another by construction of inlet cascades as well as by the applied feedback type. The principal flowsheets of the amplifiers and their main performances are presented. The analysis of the data obtained has revealed that microcircuits made of cascades with a common emitter and local combined feedback are most wide-band among all the considered microcircuits [ru

  18. Comparative study of friction between metallic and conventional interactive self-ligating brackets in different alignment conditions

    Directory of Open Access Journals (Sweden)

    Sérgio Ricardo Jakob

    2014-06-01

    Full Text Available OBJECTIVE: The aim of this study was to compare the friction between three bracket models: conventional stainless steel (Ovation, Dentsply GAC, self-ligating ceramic (In-Ovation, Denstply GAC and self-ligating stainless steel brackets (In-Ovation R, Dentsply GAC. METHODS: Five brackets were used for each model. They were bonded to an aluminum prototype that allowed the simulation of four misalignment situations (n = 10. Three of these situations occurred at the initial phase (in which a 0.016-in nickel-titanium wire was used: 1. horizontal; 2. vertical; and 3. simultaneous horizontal/vertical. One of the situations occurred at the final treatment phase: 4. no misalignment (in which a 0.019 x 0.025-inch stainless steel rectangular wire was used. The wires slipped through the brackets and friction was measured by a Universal Testing Machine. RESULTS: Analysis of variance followed by Tukey's Test for multiple comparisons (α = 0.05 were applied to assess the results. Significant interaction (p < 0.01 among groups was found. For the tests that simulated initial alignment, Ovation(r bracket produced the highest friction. The two self-ligating models resulted in lower and similar values, except for the horizontal situation, in which In-Ovation C(r showed lower friction, which was similar to the In-Ovation R(r metallic model. For the no misalignment situation, the same results were observed. CONCLUSION: The self-ligating system was superior to the conventional one due to producing less friction. With regard to the material used for manufacturing the brackets, the In-Ovation C(r ceramic model showed less friction than the metallic ones.

  19. Advances in high-power rf amplifiers

    International Nuclear Information System (INIS)

    Tallerico, P.J.

    1979-01-01

    Several powerful accelerators and storage rings are being considered that will require tens or even hundreds of megawatts of continuous rf power. The economics of such large machines can be dictated by the cost and efficiency of the rf amplifiers. The overall design and performance of such narrow-band amplifiers, operating in the 50- to 1500-MHz region, are being theoretically studied as a function of frequency to determine the optimum rf amplifier output power, gain, efficiency, and dc power requirements. The state of the art for three types of amplifiers (gridded tubes, klystrons, and gyrocons) is considered and the development work necessary to improve each is discussed. The gyrocon is a new device, hence its various embodiments are discussed in detail. The Soviet designs are reviewed and the gyrocon's strengths and weaknesses are compared to other types of microwave amplifiers. The primary advantages of the gyrocon are the very large amount of power available from a single device and the excellent efficiency and stable operation. The klystron however, has much greater gain and is simpler mechanically. At very low frequencies, the small size of the gridded tube makes it the optimum choice for all but the most powerful systems

  20. Class D audio amplifiers for high voltage capacitive transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis

    of high volume, weight, and cost. High efficient class D amplifiers are now widely available offering power densities, that their linear counterparts can not match. Unlike the technology of audio amplifiers, the loudspeaker is still based on the traditional electrodynamic transducer invented by C.W. Rice......Audio reproduction systems contains two key components, the amplifier and the loudspeaker. In the last 20 – 30 years the technology of audio amplifiers have performed a fundamental shift of paradigm. Class D audio amplifiers have replaced the linear amplifiers, suffering from the well-known issues...... with the low level of acoustical output power and complex amplifier requirements, have limited the commercial success of the technology. Horn or compression drivers are typically favoured, when high acoustic output power is required, this is however at the expense of significant distortion combined...

  1. Design and implementation of a wireless (Bluetooth) four channel bio-instrumentation amplifier and digital data acquisition device with user-selectable gain, frequency, and driven reference.

    Science.gov (United States)

    Cosmanescu, Alin; Miller, Benjamin; Magno, Terence; Ahmed, Assad; Kremenic, Ian

    2006-01-01

    A portable, multi-purpose Bio-instrumentation Amplifier and Data AcQuisition device (BADAQ) capable of measuring and transmitting EMG and EKG signals wirelessly via Bluetooth is designed and implemented. Common topologies for instrumentation amplifiers and filters are used and realized with commercially available, low-voltage, high precision operational amplifiers. An 8-bit PIC microcontroller performs 10-bit analog-to-digital conversion of the amplified and filtered signals and controls a Bluetooth transceiver capable of wirelessly transmitting the data to any Bluetooth enabled device. Electrical isolation between patient/subject, circuitry, and ancillary equipment is achieved by optocoupling components. The design focuses on simplicity, portability, and affordability.

  2. PPAR-alpha agonist treatment increases trefoil factor family-3 expression and attenuates apoptosis in the liver tissue of bile duct-ligated rats.

    Science.gov (United States)

    Karakan, Tarkan; Kerem, Mustafa; Cindoruk, Mehmet; Engin, Doruk; Alper, Murat; Akın, Okan

    2013-01-01

    Peroxisome proliferators-activated receptor alpha activation modulates cholesterol metabolism and suppresses bile acid synthesis. The trefoil factor family comprises mucin-associated proteins that increase the viscosity of mucins and help protect epithelial linings from insults. We evaluated the effect of short-term administration of fenofibrate, a peroxisome proliferators activated receptor alpha agonist, on trefoil factor family-3 expression, degree of apoptosis, generation of free radicals, and levels of proinflammatory cytokines in the liver tissue of bile duct-ligated rats. Forty male Wistar rats were randomly divided into four groups: 1 = sham operated, 2 = bile duct ligation, 3 = bile duct-ligated + vehicle (gum Arabic), and 4 = bile duct-ligated + fenofibrate (100 mg/kg/day). All rats were sacrificed on the 7 th day after obtaining blood samples and liver tissue. Liver function tests, tumor necrosis factor-alpha and interleukin 1 beta in serum, and trefoil factor family-3 mRNA expression, degree of apoptosis (TUNEL) and tissue malondialdehyde (malondialdehyde, end-product of lipid peroxidation by reactive oxygen species) in liver tissue were evaluated. Fenofibrate administration significantly reduced serum total bilirubin, aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase, gamma-glutamyl transferase, and tumor necrosis factor-alpha and interleukin-1β levels. Apoptosis and malondialdehyde were significantly reduced in the fenofibrate group. Trefoil factor family-3 expression increased with fenofibrate treatment in bile duct-ligated rats. The peroxisome proliferators-activated receptor alpha agonist fenofibrate significantly increased trefoil factor family-3 expression and decreased apoptosis and lipid peroxidation in the liver and attenuated serum levels of proinflammatory cytokines in bile duct-ligated rats. Further studies are needed to determine the protective role of fenofibrate in human cholestatic disorders.

  3. Amplified Policymaking

    Science.gov (United States)

    Prince, Katherine; Woempner, Carolyn

    2010-01-01

    This brief examines the policy implications of two drivers of change presented in the "2020 Forecast: Creating the Future of Learning"-- Pattern Recognition and Amplified Organization. These drivers point toward a series of cultural shifts and illuminate how we are developing new ways of organizing, constructing, and managing knowledge.…

  4. Amplified spontaneous emission spectrum and gain characteristic of a two-electrode semiconductor optical amplifier

    International Nuclear Information System (INIS)

    Wang Hanchao; Huang Lirong; Shi Zhongwei

    2011-01-01

    A two-electrode multi-quantum-well semiconductor optical amplifier is designed and fabricated. The amplified spontaneous emission (ASE) spectrum and gain were measured and analyzed. It is shown that the ASE spectrum and gain characteristic are greatly influencedby the distribution of the injection current density. By changing the injection current density of two electrodes, the full width at half maximum, peak wavelength, peak power of the ASE spectrum and the gain characteristic can be easily controlled. (semiconductor devices)

  5. CARM and harmonic gyro-amplifier experiments at 17 GHz

    International Nuclear Information System (INIS)

    Menninger, W.L.; Danly, B.G.; Alberti, S.; Chen, C.; Rullier, J.L.; Temkin, R.J.

    1993-01-01

    Cyclotron resonance maser amplifiers are possible sources for applications such as electron cyclotron resonance heating of fusion plasmas and driving high-gradient rf linear accelerators. For accelerator drivers, amplifiers or phase locked-oscillators are required. A 17 GHz cyclotron autoresonance maser (CARM) amplifier experiment and a 17 GHz third harmonic gyro-amplifier experiment are presently underway at the MIT Plasma Fusion Center. Using the SRL/MIT SNOMAD II introduction accelerator to provide a 380 kV, 180 A, 30 ns flat top electron beam, the gyro-amplifier experiment has produced 5 MW of rf power with over 50 dB of gain at 17 GHz. The gyro-amplifier operates in the TE 31 mode using a third harmonic interaction. Because of its high power output, the gyro-amplifier will be used as the rf source for a photocathode rf electron gun experiment also taking place at MIT. Preliminary gyro-amplifier results are presented, including measurement of rf power, gain versus interaction length, and the far-field pattern. A CARM experiment designed to operate in the TE 11 mode is also discussed

  6. Characterization of a Common-Gate Amplifier Using Ferroelectric Transistors

    Science.gov (United States)

    Hunt, Mitchell; Sayyah, Rana; MacLeod, Todd C.; Ho, Fat D.

    2011-01-01

    In this paper, the empirical data collected through experiments performed using a FeFET in the common-gate amplifier circuit is presented. The FeFET common-gate amplifier was characterized by varying all parameters in the circuit, such as load resistance, biasing of the transistor, and input voltages. Due to the polarization of the ferroelectric layer, the particular behavior of the FeFET common-gate amplifier presents interesting results. Furthermore, the differences between a FeFET common-gate amplifier and a MOSFET common-gate amplifier are examined.

  7. PDA Ligation in Adults – A 2-years Experience in Tikur Anbassa ...

    African Journals Online (AJOL)

    Fifty four percent of pts had PDA size 5-8mm.One patient died during reoperation . Conclusion: In developed countries , PDA is exclusively managed at infancy but in developing countries like ours, PDA may present in adults with symptoms and if there is no evidence of significant pulmonary hypertension ,PDA ligation is ...

  8. The design of high performance weak current integrated amplifier

    International Nuclear Information System (INIS)

    Chen Guojie; Cao Hui

    2005-01-01

    A design method of high performance weak current integrated amplifier using ICL7650 operational amplifier is introduced. The operating principle of circuits and the step of improving amplifier's performance are illustrated. Finally, the experimental results are given. The amplifier has programmable measurement range of 10 -9 -10 -12 A, automatic zero-correction, accurate measurement, and good stability. (authors)

  9. Microchannel plates as detectors and amplifiers of x-ray images

    International Nuclear Information System (INIS)

    Wiedwald, J.D.

    1992-08-01

    Two decades of development driven largely by military night vision applications has led to the availability of a wide selection of microchannel plates for use by the scientific community. Microchannel plates (MCPs) are electron multipliers which retain a high degree of spatial resolution making it possible to amplify electron images by factors of 1,000 or more. Plates having 40 mm diameter and intrinsic spatial resolution of 8 μm are readily available. By coating the front surface of a microchannel plate with an x-ray sensitive photocathode material, x-ray images can be detected and amplified. While the detective quantum efficiency is relatively low, the low noise of the MCP (including the ability to construct images by single photon detection) and its high dynamic range make it suitable for some x-ray microscopy applications. The principles of MCP operation and typical performance are discussed. Examples of related applications and commercial capabilities are also presented

  10. Quantum Dot Semiconductor Optical Amplifiers - Physics and Applications

    DEFF Research Database (Denmark)

    Berg, Tommy Winther

    2004-01-01

    This thesis describes the physics and applications of quantum dot semiconductor optical amplifiers based on numerical simulations. These devices possess a number of unique properties compared with other types of semiconductor amplifiers, which should allow enhanced performance of semiconductor...... respects is comparable to those of fiber amplifiers. The possibility of inverting the optically active states to a large degree is essential in order to achieve this performance. Optical signal processing through cross gain modulation and four wave mixing is modeled and described. For both approaches...... and QW devices and to experiments on quantum dot amplifiers. These comparisons outline the qualitative differences between the different types of amplifiers. In all cases focus is put on the physical processes responsible the differences....

  11. Analog circuit design designing high performance amplifiers

    CERN Document Server

    Feucht, Dennis

    2010-01-01

    The third volume Designing High Performance Amplifiers applies the concepts from the first two volumes. It is an advanced treatment of amplifier design/analysis emphasizing both wideband and precision amplification.

  12. High power X-band coaxial amplifier experiments

    International Nuclear Information System (INIS)

    Davis, T.J.; Nation, J.A.

    1991-01-01

    Studies are continuing on the development of X-band coaxial microwave amplifiers as a source for next generation linear colliders. Coaxial amplifiers employ an annular electron beam propagating between inner and outer drift tube conductors, a configuration which allows large increases in beam current over standard pencil beam amplifiers. Large average diameter systems may still be used without mode competition since TM mode cutoff frequencies are controlled by the separation between conductors. A number of amplifier configurations are being studied, all primed by a driven initial cavity which resonates around 9 GHz. Simple theory of coaxial systems and particle-in-cell simulations are presented, as well as initial experimental results using a 420 keV, 7-8 kA, 9 cm diameter annular beam

  13. Wideband multi-element Er-doped fiber amplifier

    International Nuclear Information System (INIS)

    Thipparapu, N K; Jain, S; May-Smith, T C; Sahu, J K

    2014-01-01

    A multi-element Er-doped fiber amplifier (MEEDFA) is demonstrated in which the gain profile is extended into the S and L bands. Each fiber element of the MEEDFA is found to provide a maximum gain of 37 dB and a noise figure of < 4 dB in the C-band. The gain profile of the amplifier is shifted towards longer wavelength by cascading fiber elements. The novel geometry of the multi-element fiber (MEF) could allow for the development of a broadband amplifier in a split-band configuration. The proposed amplifier can operate in the wavelength band of 1520 to 1595 nm (75 nm), with a minimum gain of 20 dB. (letter)

  14. Comparison of infrared coagulation and rubber band ligation for first and second degree haemorrhoids: a randomised prospective clinical trial.

    OpenAIRE

    Templeton, J L; Spence, R A; Kennedy, T L; Parks, T G; Mackenzie, G; Hanna, W A

    1983-01-01

    One hundred and thirty seven previously untreated out-patients with first and second degree haemorrhoids were allocated at random to treatment by infrared coagulation (n=66) or rubber band ligation (n=71). Complete follow up was obtained in 122 patients (60 who had undergone infrared coagulation (group 1), and 62 rubber band ligation (group 2)) at periods from three months to one year after completion of treatment. Infrared coagulation produced a satisfactory outcome in 51 patients (85%): 34 ...

  15. Tubal ligation and salpingectomy and the risk of epithelial ovarian cancer and borderline ovarian tumors

    DEFF Research Database (Denmark)

    Madsen, C; Baandrup, Louise; Dehlendorff, Christian

    2015-01-01

    OBJECTIVE: According to the recent theories on the ovarian cancer origin, any protective effect of tubal ligation may vary with histologic subtype of ovarian cancer. Furthermore, bilateral salpingectomy may represent an opportunity for surgical prevention of serous ovarian cancer. DESIGN: Nationw......OBJECTIVE: According to the recent theories on the ovarian cancer origin, any protective effect of tubal ligation may vary with histologic subtype of ovarian cancer. Furthermore, bilateral salpingectomy may represent an opportunity for surgical prevention of serous ovarian cancer. DESIGN...... sampling. We required that cases and controls have no previous cancer and that controls have no previous bilateral oophorectomy. METHODS: Conditional logistic regression was used to estimate odds ratios and 95% confidence intervals, adjusting for potential confounders. MAIN OUTCOME MEASURES: Epithelial...

  16. A parallel input composite transimpedance amplifier

    Science.gov (United States)

    Kim, D. J.; Kim, C.

    2018-01-01

    A new approach to high performance current to voltage preamplifier design is presented. The design using multiple operational amplifiers (op-amps) has a parasitic capacitance compensation network and a composite amplifier topology for fast, precision, and low noise performance. The input stage consisting of a parallel linked JFET op-amps and a high-speed bipolar junction transistor (BJT) gain stage driving the output in the composite amplifier topology, cooperating with the capacitance compensation feedback network, ensures wide bandwidth stability in the presence of input capacitance above 40 nF. The design is ideal for any two-probe measurement, including high impedance transport and scanning tunneling microscopy measurements.

  17. Unconditionally stable microwave Si-IMPATT amplifiers

    International Nuclear Information System (INIS)

    Seddik, M.M.

    1986-07-01

    The purpose of this investigation has been the development of an improved understanding of the design and analysis of microwave reflection amplifiers employing the negative resistance property of the IMPATT devices. Unconditionally stable amplifier circuit using a Silicon IMPATT diode is designed. The problems associated with the design procedures and the stability criterion are discussed. A computer program is developed to perform the computations. The stable characteristics of a reflection-type Si-IMPATT amplifier, such as gain, frequency and bandwidth are examined. It was found that at large signal drive levels, 7 dB gain with bandwidth of 800 MHz at 22,5 mA was obtained. (author)

  18. Bilateral tubal ligation in a rural hospital in the Niger Delta, Nigeria ...

    African Journals Online (AJOL)

    Background and Objective: To document bilateral tubal ligation (BTL) rate and highlight the need to improve on the rates. Materials and Methods: A retrospective review of BTLs done in a five-year period from January 2000 to December 2004 constituted the study group. Results: There were a total of 103 BTLs, 58 were ...

  19. Low noise amplifier for ZnS(Ag) scintillation chamber

    International Nuclear Information System (INIS)

    Do Hoang Cuong

    1998-01-01

    A new pulse amplifier that can be used with standard photomultiplier tubes coupled with Zn(Ag) scintillation chamber is presented. The amplifier based on an IC operational amplifier LF 356N consists of a low-noise charge sensitive preamplifier and pulse shaping circuits for optimization of signal to noise ratio. Temperature instability is ≤ 0.05%/ o C. Dynamic range for linear output signals is equal +7 V. The presented amplifier is used in a measuring head for 0.17 L Lucas chambers developed in Department of Nuclear Instruments and Methods of the INCT in laboratory investigations aimed to develop methods and instruments for measurement of radon concentration in the air. The amplifier can also be employed for measurement of ionizing radiation by means of other scintillators coupled to PM tube. The amplifier is followed by a pulse discriminator with adjustable discrimination level. The amplifier output signal and discriminator output pulses are fed to external devices. (author)

  20. Effects of CD44 Ligation on Signaling and Metabolic Pathways in Acute Myeloid Leukemia

    KAUST Repository

    Madhoun, Nour Y.

    2017-01-01

    Acute myeloid leukemia (AML) is characterized by a blockage in the differentiation of myeloid cells at different stages. CD44-ligation using anti-CD44 monoclonal antibodies (mAbs) has been shown to reverse the blockage of differentiation

  1. Transpermeance Amplifier Applied to Magnetic Bearings

    Directory of Open Access Journals (Sweden)

    Jossana Ferreira

    2017-02-01

    Full Text Available The most conventional approach of controlling magnetic forces in active magnetic bearings (AMBs is through current feedback amplifiers: transconductance. This enables the operation of the AMB to be understood in terms of a relatively simple current-based model as has been widely reported on in the literature. The alternative notion of using transpermeance amplifiers, which approximate the feedback of gap flux rather than current, has been in commercial use in some form for at least thirty years, however is only recently seeing more widespread acceptance as a commercial standard. This study explores how such alternative amplifiers should be modeled and then examines the differences in behavior between AMBs equipped with transconductance and transpermeance amplifiers. The focus of this study is on two aspects. The first is the influence of rotor displacement on AMB force, commonly modeled as a constant negative equivalent mechanical stiffness, and it is shown that either scheme actually leads to a finite bandwidth effect, but that this bandwidth is much lower when transpermeance is employed. The second aspect is the influence of eddy currents. Using a very simple model of eddy currents (a secondary short-circuited coil, it is demonstrated that transpermeance amplifiers can recover significant actuator bandwidth compared with transconductance, but at the cost of needing increased peak current headroom.

  2. A high-power two stage traveling-wave tube amplifier

    International Nuclear Information System (INIS)

    Shiffler, D.; Nation, J.A.; Schachter, L.; Ivers, J.D.; Kerslick, G.S.

    1991-01-01

    Results are presented on the development of a two stage high-efficiency, high-power 8.76-GHz traveling-wave tube amplifier. The work presented augments previously reported data on a single stage amplifier and presents new data on the operational characteristics of two identical amplifiers operated in series and separated from each other by a sever. Peak powers of 410 MW have been obtained over the complete pulse duration of the device, with a conversion efficiency from the electron beam to microwave energy of 45%. In all operating conditions the severed amplifier showed a ''sideband''-like structure in the frequency spectrum of the microwave radiation. A similar structure was apparent at output powers in excess of 70 MW in the single stage device. The frequencies of the ''sidebands'' are not symmetric with respect to the center frequency. The maximum, single frequency, average output power was 210 MW corresponding to an amplifier efficiency of 24%. Simulation data is also presented that indicates that the short amplifiers used in this work exhibit significant differences in behavior from conventional low-power amplifiers. These include finite length effects on the gain characteristics, which may account for the observed narrow bandwidth of the amplifiers and for the appearance of the sidebands. It is also found that the bunching length for the beam may be a significant fraction of the total amplifier length

  3. Performance analysis of best relay selection scheme for amplify-and-forward cooperative networks in identical Nakagami-m channels

    KAUST Repository

    Hussain, Syed Imtiaz; Alouini, Mohamed-Slim; Hasna, Mazen Omar

    2010-01-01

    for a cooperative network with multiple relays operating in amplify-and-forward (AF) mode over identical Nakagami-m channels using exact source-relay-destination signal to noise ratio (SNR) expression. We derive accurate closed form expressions

  4. Evaluation of the Friction of Self-Ligating and Conventional Bracket Systems

    Science.gov (United States)

    Tecco, Simona; Di Iorio, Donato; Nucera, Riccardo; Di Bisceglie, Beatrice; Cordasco, Giancarlo; Festa, Felice

    2011-01-01

    Objectives: This in vitro study evaluated the friction (F) generated by aligned stainless steel (SS) conventional brackets, self-ligating Damon MX© brackets (SDS Ormco, Glendora, California, USA), Time3© brackets (American Orthodontics, Sheboygan, Wisconsin, USA), Vision LP© brackets (American Orthodontics), and low-friction Slide© ligatures (Leone, Firenze, Italy) coupled with various SS, nickel-titanium (NiTi), and beta-titanium (TMA) archwires. Methods: All brackets had a 0.022-inch slot, and the orthodontic archwires were 0.014-inch, 0.016-inch, 0.014×0.025-inch, 0.018×0.025-inch, and 0.019×0.025-inch NiTi; 0.017×0.025-inch TMA; and 0.019×0.025-inch SS. Each bracket-archwire combination was tested 10 times. In the test, 10 brackets of the same group were mounted in alignment on a metal bar. The archwires moved through all the 10 brackets at a crosshead speed of 0.5 mm/min (each run lasted approximately 5 min). The differences among 5 groups of brackets were analyzed through the Kruskal-Wallis test, and a Mann-Whitney test was calculated as post hoc analysis. The P value was set at 0.05. Results: Coupled with 0.014-inch NiTi and 0.016-inch NiTi, Victory Series© brackets generated the greatest F, while Damon MX© and Vision LP© brackets generated the lowest (Pbrackets and Slide© ligatures. Coupled with all the rectangular archwires, Victory Series© brackets, Slide© ligatures, and Vision LP© self-ligating brackets generated significantly lower F than did Time3© and Damon MX© self-ligating brackets (Pbrackets are a family of brackets that, in vitro, can generate different levels of F when coupled with thin or thick, rectangular, or round archwires. Clinical conclusions based on our results are not possible due to the limitations of the experimental conditions. PMID:21769273

  5. Characterization of the Endothelial Cell Cytoskeleton following HLA Class I Ligation

    Science.gov (United States)

    Ziegler, Mary E.; Souda, Puneet; Jin, Yi-Ping; Whitelegge, Julian P.; Reed, Elaine F.

    2012-01-01

    Background Vascular endothelial cells (ECs) are a target of antibody-mediated allograft rejection. In vitro, when the HLA class I molecules on the surface of ECs are ligated by anti-HLA class I antibodies, cell proliferation and survival pathways are activated and this is thought to contribute to the development of antibody-mediated rejection. Crosslinking of HLA class I molecules by anti-HLA antibodies also triggers reorganization of the cytoskeleton, which induces the formation of F-actin stress fibers. HLA class I induced stress fiber formation is not well understood. Methodology and Principal Findings The present study examines the protein composition of the cytoskeleton fraction of ECs treated with HLA class I antibodies and compares it to other agonists known to induce alterations of the cytoskeleton in endothelial cells. Analysis by tandem mass spectrometry revealed unique cytoskeleton proteomes for each treatment group. Using annotation tools a candidate list was created that revealed 12 proteins, which were unique to the HLA class I stimulated group. Eleven of the candidate proteins were phosphoproteins and exploration of their predicted kinases provided clues as to how these proteins may contribute to the understanding of HLA class I induced antibody-mediated rejection. Three of the candidates, eukaryotic initiation factor 4A1 (eIF4A1), Tropomyosin alpha 4-chain (TPM4) and DDX3X, were further characterized by Western blot and found to be associated with the cytoskeleton. Confocal microscopy analysis showed that class I ligation stimulated increased eIF4A1 co-localization with F-actin and paxillin. Conclusions/Significance Colocalization of eIF4A1 with F-actin and paxillin following HLA class I ligation suggests that this candidate protein could be a target for understanding the mechanism(s) of class I mediated antibody-mediated rejection. This proteomic approach for analyzing the cytoskeleton of ECs can be applied to other agonists and various cells types

  6. ANESTHESIA MANAGEMENT OF 775 GRAMS PREMATURE PATIENT DURING PDA LIGATION-A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Gulsen KESKiN

    2016-03-01

    We believe that VLBW preterm infants by having multiple system failure may have PDA ligation in operating room if there is no optimum conditions in ICU by obtaining safe transport, performing ketamine in anesthesia induction and maintenance. [J Contemp Med 2016; 6(1.000: 47-50

  7. Photonic-band-gap gyrotron amplifier with picosecond pulses

    Science.gov (United States)

    Nanni, Emilio A.; Jawla, Sudheer; Lewis, Samantha M.; Shapiro, Michael A.; Temkin, Richard J.

    2017-12-01

    We report the amplification of 250 GHz pulses as short as 260 ps without observation of pulse broadening using a photonic-band-gap circuit gyrotron traveling-wave-amplifier. The gyrotron amplifier operates with a device gain of 38 dB and an instantaneous bandwidth of 8 GHz. The operational bandwidth of the amplifier can be tuned over 16 GHz by adjusting the operating voltage of the electron beam and the magnetic field. The amplifier uses a 30 cm long photonic-band-gap interaction circuit to confine the desired TE03-like operating mode while suppressing lower order modes which can result in undesired oscillations. The circuit gain is >55 dB for a beam voltage of 23 kV and a current of 700 mA. These results demonstrate the wide bandwidths and a high gain achievable with gyrotron amplifiers. The amplification of picosecond pulses of variable lengths, 260-800 ps, shows good agreement with the theory using the coupled dispersion relation and the gain-spectrum of the amplifier as measured with quasi-CW input pulses.

  8. Single conversion stage amplifier - SICAM

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.

    2005-12-15

    This Ph.D. thesis presents a thorough analysis of the so called SICAM - SIngle Converter stage AMplifier approach to building direct energy conversion audio power amplifiers. The mainstream approach for building isolated audio power amplifiers today consists of isolated DC power supply and Class D amplifier, which essentially represents a two stage solution, where each of the components can be viewed as separate and independent part. The proposed SICAM solution strives for direct energy conversion from the mains to the audio output, by dedicating the operation of the components one to another and integrating their functions, so that the final audio power amplifier represents a single-stage topology with higher efficiency, lower volume, less board space, lower component count and subsequently lower cost. The SICAM approach is both applicable to non-isolated and isolated audio power amplifiers, but the problems encountered in these two cases are different. Non-isolated SICAM solutions are intended for both AC mains-connected and battery-powered devices. In non-isolated mains-connected SICAMs the main idea is to simplify the power supply or even provide integrated power factor correction (PFC) functions, while still maintaining low component stress and good audio performance by generally decreasing the input voltage level to the Class D audio power amplifier. On the other hand, non-isolated battery-powered SICAMs have to cope with the ever changing battery voltage and provide output voltage levels which are both lower and higher than the battery voltage, while still being simple and single-stage energy conversion solutions. In isolated SICAMs the isolation transformer adjusts the voltage level on the secondary side to the desired level, so the main challenges here are decreasing the size of the magnetic core and reducing the number and size of bulky reactive components as much as possible. The main focus of this thesis is directed towards the isolated SICAMs and

  9. Characterization of a Common-Source Amplifier Using Ferroelectric Transistors

    Science.gov (United States)

    Hunt, Mitchell; Sayyah, Rana; MacLeond, Todd C.; Ho, Pat D.

    2010-01-01

    This paper presents empirical data that was collected through experiments using a FeFET in the established common-source amplifier circuit. The unique behavior of the FeFET lends itself to interesting and useful operation in this widely used common-source amplifier. The paper examines the effect of using a ferroelectric transistor for the amplifier. It also examines the effects of varying load resistance, biasing, and input voltages on the output signal and gives several examples of the output of the amplifier for a given input. The difference between a commonsource amplifier using a ferroelectric transistor and that using a MOSFET is addressed.

  10. Class-D audio amplifiers with negative feedback

    OpenAIRE

    Cox, Stephen M.; Candy, B. H.

    2006-01-01

    There are many different designs for audio amplifiers. Class-D, or switching, amplifiers generate their output signal in the form of a high-frequency square wave of variable duty cycle (ratio of on time to off time). The square-wave nature of the output allows a particularly efficient output stage, with minimal losses. The output is ultimately filtered to remove components of the spectrum above the audio range. Mathematical models are derived here for a variety of related class-D amplifier de...

  11. Biphasic activation of liver regeneration-associated signals in an early stage after portal vein branch ligation

    International Nuclear Information System (INIS)

    Yokoyama, Shinya; Yokoyama, Yukihiro; Kawai, Toru; Kobayashi, Satoshi; Nagino, Masato; Oda, Koji; Nimura, Yuji; Sokabe, Masahiro

    2006-01-01

    At an early stage in liver regeneration, a variety of factors including transcriptional factors, proinflammatory cytokines, and proto-oncogenes are activated or expressed. However, these responses are affected by surgical stress in the conventional portal vein branch ligation model (PVL). We sought to determine the net activation of early regeneration-associated signals after PVL using a newly developed non-surgical stress PVL model. Male Wistar rats were assigned into two groups, a stress-PVL (sPVL) model with laparotomy and portal vein branch ligation, and a non-stress-PVL (nsPVL) one subjected to portal vein branch ligation 1 week after laparotomy in which the effects of surgical stress were subsided. The activation of transcriptional factors and expression of immediate early genes were analyzed at an early time point (within 24 h) by Western blotting and RT-PCR, respectively. A monophasic upregulation of nuclear factor-κB (NF-κB) and phosphorylated-signal transducer and activator of transcription 3 (p-STAT3) peaked at 3 h after sPVL was observed. In contrast, the expression pattern of these factors was biphasic (first peak at 0.5-1 h, second peak at 3-6 h) in nsPVL group. The expression pattern of immediate early genes showed a similar trend between sPVL and nsPVL. cDNA array analysis for the non-ligated lobe at 2 h after PVL revealed a much higher gene activation in sPVL than in nsPVL. These results indicate that previously observed activation pattern of regeneration-associated signals after PVL is significantly affected by the effect of laparotomy and our results using nsPVL model may more accurately represent liver regeneration-associated signal pattern

  12. Differential transimpedance amplifier circuit for correlated differential amplification

    Science.gov (United States)

    Gresham, Christopher A [Albuquerque, NM; Denton, M Bonner [Tucson, AZ; Sperline, Roger P [Tucson, AZ

    2008-07-22

    A differential transimpedance amplifier circuit for correlated differential amplification. The amplifier circuit increase electronic signal-to-noise ratios in charge detection circuits designed for the detection of very small quantities of electrical charge and/or very weak electromagnetic waves. A differential, integrating capacitive transimpedance amplifier integrated circuit comprising capacitor feedback loops performs time-correlated subtraction of noise.

  13. Evaluation of cerebral electrical activity and cardiac output after patent ductus arteriosus ligation in preterm infants.

    LENUS (Irish Health Repository)

    Leslie, A T F S

    2013-11-01

    To characterize and investigate the relationship between systemic blood flow and pre- and postoperative cerebral electrical activity in preterm neonates undergoing patent ductus arteriosus (PDA) ligation.

  14. Ring cavity for a Raman capillary waveguide amplifier

    Science.gov (United States)

    Kurnit, N.A.

    1981-01-27

    A regenerative ring amplifier and regenerative ring oscillator are described which function to feed back a portion of the Stokes signal to complete the ring cavity. The ring cavity configuration allows the CO/sub 2/ laser pump signal and Stokes signal to copropagate through the Raman capillary waveguide amplifier. A Raman capillary waveguide amplifier is also provided in the return leg of the ring cavity to increase gain without increasing the round trip time. Additionally, the ring cavity can be designed such that the amplified Stokes signal is synchronous with the mode-locked spikes of the incoming CO/sub 2/ laser pump signal.

  15. Synthetic study on prion protein fragments using a SPPS and native chemical ligation

    Czech Academy of Sciences Publication Activity Database

    Zawada, Z.; Šebestík, Jaroslav; Bednárová, Lucie; Bouř, Petr; Hlaváček, Jan; Stibor, Ivan

    2009-01-01

    Roč. 37, Suppl. 1 (2009), s. 44-44 ISSN 0939-4451. [International Congress on Amino Acids, Peptides and Proteins /11./. 03.08.2009-07.08.2009, Vienna] Institutional research plan: CEZ:AV0Z40550506 Keywords : prion protein * SPPS * native chemical ligation * fragments Subject RIV: CC - Organic Chemistry

  16. Treatment of grade 2 and 3 hemorrhoids with Doppler-guided hemorrhoidal artery ligation

    NARCIS (Netherlands)

    Wallis de Vries, B. M.; van der Beek, E. S. J.; de Wijkerslooth, L. R. H.; van der Zwet, W. C.; van der Hoeven, J. A. B.; Eeftinck Schattenkerk, M.; Eddes, E. H.

    2007-01-01

    We evaluated the results of the Doppler-guided hemorrhoidal arterial ligation (DG-HAL) method in the management of symptomatic grade 2 and 3 hemorrhoids. Between June 2005 and March 2006, 110 consecutive patients with symptomatic grade 2 and 3 hemorrhoids according to the DG-HAL method were treated.

  17. A high-efficiency superconductor distributed amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Herr, Q P, E-mail: quentin.herr@ngc.co [Northrop Grumman Corporation, 7323 Aviation Boulevard, Baltimore, MD 21240 (United States)

    2010-02-15

    A superconductor output amplifier that converts single-flux-quantum signals to a non-return-to-zero pattern is reported using a twelve-stage distributed amplifier configuration. The output amplitude is measured to be 1.75 mV over a wide bias current range of {+-} 12%. The bit error rate is measured using a Delta-Sigma data pattern to be less than 1 x 10{sup -9} at 10 Gb s{sup -1} per channel. Analysis of the eye diagram suggests that the actual bit error rate may be much lower. The amplifier has power efficiency of 12% neglecting the termination resistor, which may be eliminated from the circuit with a small modification. (rapid communication)

  18. Fundamentals of RF and microwave transistor amplifiers

    CERN Document Server

    Bahl, Inder J

    2009-01-01

    A Comprehensive and Up-to-Date Treatment of RF and Microwave Transistor Amplifiers This book provides state-of-the-art coverage of RF and microwave transistor amplifiers, including low-noise, narrowband, broadband, linear, high-power, high-efficiency, and high-voltage. Topics covered include modeling, analysis, design, packaging, and thermal and fabrication considerations. Through a unique integration of theory and practice, readers will learn to solve amplifier-related design problems ranging from matching networks to biasing and stability. More than 240 problems are included to help read

  19. Design And Construction Of 300W Audio Power Amplifier For Classroom

    Directory of Open Access Journals (Sweden)

    Shune Lei Aung

    2015-07-01

    Full Text Available Abstract This paper describes the design and construction of 300W audio power amplifier for classroom. In the construction of this amplifier microphone preamplifier tone preamplifier equalizer line amplifier output power amplifier and sound level indicator are included. The output power amplifier is designed as O.C.L system and constructed by using Class B among many types of amplifier classes. There are two types in O.C.L system quasi system and complementary system. Between them the complementary system is used in the construction of 300W audio power amplifier. The Multisim software is utilized for the construction of audio power amplifier.

  20. The role of prophylactic internal iliac artery ligation in abnormally invasive placenta undergoing caesarean hysterectomy: a randomized control trial.

    Science.gov (United States)

    Hussein, Ahmed M; Dakhly, Dina Mohamed Refaat; Raslan, Ayman N; Kamel, Ahmed; Abdel Hafeez, Ali; Moussa, Manal; Hosny, Ahmed Samir; Momtaz, Mohamed

    2018-04-25

    To identify the role of bilateral internal iliac artery (IIA) ligation on reducing blood loss in abnormally invasive placenta (AIP) undergoing caesarean hysterectomy. In this parallel-randomized control trial, 57 pregnant females with ultrasound features suggestive of AIP were enrolled. They were randomized into two groups; IIA group (n = 29 cases) performed bilateral IIA ligation followed by caesarean hysterectomies, while Control group (n = 28 cases) underwent caesarean hysterectomy only. The main outcome was the difference in the estimated intraoperative blood loss between the two groups. There was no significant difference between the two groups regarding the intraoperative estimated blood loss (1632 ± 804 versus 1698 ± 1251, p value .83). The operative procedure duration (minutes) (223 ± 66 versus 171 ± 41.4, p value .001) varied significantly between the two groups. Bilateral internal iliac artery ligation, in cases of AIP undergoing caesarean hysterectomy, is not recommended for routine practice to minimize blood loss intraoperatively.

  1. Swimming performance, venous oxygen tension and cardiac performance of coronary-ligated rainbow trout, Oncorhynchus mykiss, exposed to progressive hypoxia

    DEFF Research Database (Denmark)

    Steffensen, J F; Farrell, A P

    1998-01-01

    We performed in vivo studies to examine the idea that cardiac work is impaired in rainbow trout (Oncorhynchus mykiss) below a certain venous PO2 threshold. We hypothesized that coronary-ligated fish, swimming continuously at a reasonably high water velocity (1.5 body lengths x s(-1)) and exposed...... to progressive hypoxia, would fatigue at higher venous PO2 and ambient water PO2 compared with sham-operated fish. However, we found that both the lowest venous PO2 that supported hypoxic swimming (9.9 torr for coronary-ligated fish and 11.1 torr for sham-operated fish) and the venous PO2 at fatigue (7.8 torr...... and 8.6 torr, respectively) were the same for coronary-ligated and sham-operated fish. Also, both groups quit swimming at the same water PO2 heart rate and hematocrit. Nevertheless, significant differences in cardiac performance did exist between the two groups. Whereas ventral aortic blood pressure...

  2. Evaluation of the force generated by gradual deflection of orthodontic wires in conventional metallic, esthetic, and self-ligating brackets.

    Science.gov (United States)

    Francisconi, Manoela Fávaro; Janson, Guilherme; Henriques, José Fernando Castanha; Freitas, Karina Maria Salvatore de

    2016-01-01

    The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual increase in wire diameter and deflection and comparing different combinations in the different deflections. Specimens were set in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using the ISO 15841 protocol. Data were subjected to One-way ANOVA, followed by Tukey tests (pbrackets presented the most similar behavior to each other. For conventional brackets there was no consistent behavior for any of the deflections studied. Self-ligating brackets presented the most consistent and predictable results while conventional brackets, as esthetic brackets, showed very different patterns of forces. Self-ligating brackets showed higher strength in all deflections when compared with the others, in 0.020-inch wires.

  3. Surgical Ligation of Patent Ductus Arteriosus in Very-low-birth-weight Premature Infants in the Neonatal Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Yu-Chen Ko

    2009-01-01

    Full Text Available This study reported our experience of bedside patent ductus arteriosus (PDA ligation for prematurity in the neonatal intensive care unit (NICU. Between April 1992 and March 2006, 41 very-low-birth-weight premature infants underwent PDA ligation in the NICU. There were 18 male and 23 female infants. The mean gestational age and birth weight were 26.9 weeks and 900.9 g, respectively. Preoperatively, 25 infants were ventilator-dependent. After operation, there were five deaths caused by complications of prematurity. Surgical complications occurred in four and all recovered well after treatment. Twenty preoperatively intubated babies survived and were extubated at 21.6 ± 12.7 days postoperatively. In conclusion, bedside PDA ligation in the NICU is safe and effective. It can avoid transportation of critically ill, very small infants. We suggest surgical closure as the primary treatment in very-low-birth-weight infants who are ventilator-dependent to avoid the possible complications of indomethacin and prolonged intubation.

  4. Self-pulsation in Raman fiber amplifiers

    DEFF Research Database (Denmark)

    Pedersen, Martin Erland Vestergaard; Ott, Johan Raunkjær; Rottwitt, Karsten

    2009-01-01

    Dynamic behavior caused by Brillouin scattering in Raman fiber amplifiers is studied. Modes of self-pulsation steady state oscillations are found. Their dependence on amplification scheme is demonstrated.......Dynamic behavior caused by Brillouin scattering in Raman fiber amplifiers is studied. Modes of self-pulsation steady state oscillations are found. Their dependence on amplification scheme is demonstrated....

  5. Computer-Aided Design of Microstrip GaAs Mesfet Amplifiers

    DEFF Research Database (Denmark)

    Nielsen, Niels Ole

    1976-01-01

    Results on computer-aided design of broadband GaAs MESFET amplifiers in microstrip is presented. The analysis of an amplifier is based on measured scattering parameters and a model of the microstrip structure, which includes parasitics and junction effects. The optimized performance of one stage...... amplifiers with lossless distributed matching elements is presented. Realized amplifiers are in good agreement with the theory. One stage amplifiers with a 1 ¿m FET in chip form exhibit 5.8 dB of gain in the range 8-12 GHz, while a gain of 4.5 dB from 4-8 GHz has been obtained with a packaged 1 ¿m FET....

  6. Note: A high dynamic range, linear response transimpedance amplifier.

    Science.gov (United States)

    Eckel, S; Sushkov, A O; Lamoreaux, S K

    2012-02-01

    We have built a high dynamic range (nine decade) transimpedance amplifier with a linear response. The amplifier uses junction-gate field effect transistors (JFETs) to switch between three different resistors in the feedback of a low input bias current operational amplifier. This allows for the creation of multiple outputs, each with a linear response and a different transimpedance gain. The overall bandwidth of the transimpedance amplifier is set by the bandwidth of the most sensitive range. For our application, we demonstrate a three-stage amplifier with transimpedance gains of approximately 10(9)Ω, 3 × 10(7)Ω, and 10(4)Ω with a bandwidth of 100 Hz.

  7. Construction of expression vector containing glnA gene and detection of NPT II activity in the transgenic rice calli using 32P-labelled compound

    International Nuclear Information System (INIS)

    Su Jin; Zhang Xueqin; Yan Qiusheng; Chen Zhangliang; You Chongbiao

    1993-08-01

    The glnA gene encoding glutamine synthetase (GS) was amplified from Azospirillum brasilense Sp7 by PCR technique. the amplified 1.4 kb DNA fragment was cloned at the EcoRV site of Bluescript-SK. Both sequencing and restriction digestion data showed that the 1.4 kb DNA fragment flanked with BamHI site at each end was really the glnA gene of A. brasilense Sp7. The glnA gene was ligated with Bg1 II site of pCo24. As a result, an expression vector pGSC35 with CaMV35S promoter was obtained. Using colony in situ hybridization with α- 32 P-dATP labelled probes to screen the positive clones, another glnA gene expression vector pAGNB92 with rice actin 1 promoter was constructed after three rounds of ligation and transformation. Protoplasts isolated from rice cell suspension line cv. T986 were transformed with glnA expression vectors pGSC35 and pAGNB92 containing neomycin phosphotransferase II (NPTII) gene by using PEG fusion and electroporation. Transformed microcalli were selected on media containing G418 disulfate salt. NPT II activity was detected in 37% of G418 resistant calli by using dot blot hybridization with γ- 32 P-ATP and kanamycin as substrate

  8. Higher order mode optical fiber Raman amplifiers

    DEFF Research Database (Denmark)

    Rottwitt, Karsten; Friis, Søren Michael Mørk; Usuga Castaneda, Mario A.

    2016-01-01

    We review higher order mode Raman amplifiers and discuss recent theoretical as well as experimental results including system demonstrations.......We review higher order mode Raman amplifiers and discuss recent theoretical as well as experimental results including system demonstrations....

  9. Stimulated Brillouin scattering threshold in fiber amplifiers

    International Nuclear Information System (INIS)

    Liang Liping; Chang Liping

    2011-01-01

    Based on the wave coupling theory and the evolution model of the critical pump power (or Brillouin threshold) for stimulated Brillouin scattering (SBS) in double-clad fiber amplifiers, the influence of signal bandwidth, fiber-core diameter and amplifier gain on SBS threshold is simulated theoretically. And experimental measurements of SBS are presented in ytterbium-doped double-clad fiber amplifiers with single-frequency hundred nanosecond pulse amplification. Under different input signal pulses, the forward amplified pulse distortion is observed when the pulse energy is up to 660 nJ and the peak power is up to 3.3 W in the pulse amplification with pulse duration of 200 ns and repetition rate of 1 Hz. And the backward SBS narrow pulse appears. The pulse peak power equals to SBS threshold. Good agreement is shown between the modeled and experimental data. (authors)

  10. Low-cost amplifier for alpha detection with photodiode

    Energy Technology Data Exchange (ETDEWEB)

    Domienikan, Cláudio; Costa, Priscila; Genezini, Frederico A.; Zahn, Guilherme S., E-mail: clanikan@ipen.br, E-mail: pcosta@ipen.br, E-mail: fredzini@ipen.br, E-mail: gzahn@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    A low-cost amplifier for Hamamatsu S3590-09 PIN photodiode to be used in alpha detection is presented. This amplifier consists basically of two circuits: a pulse preamplifier and a shaper-driver. The PIN photodiode is reverse-biased and connected to a charge preamplifier input. Incident alpha particles generate a small current pulse in the photodiode. The integrating circuit of the low noise preamplifier transforms current pulse into a voltage pulse with amplitude proportional to the charge carried by the current pulse. The shaper-driver consists of a differentiator and an integrator and is responsible for filtering and further amplifying the preamplifier signal, generating a NIM-compatible energy pulse. The performance of the set photodiode-amplifier was successively tested through the use of a {sup 243}Am radioactive source. The low-cost photodiode amplifier was designed and constructed at IPEN - CNEN/SP using national components and expertise. (author)

  11. Simulations of longitudinally pumped dye laser amplifier

    International Nuclear Information System (INIS)

    Takehisa, Kiwamu; Takemori, Satoshi

    1995-01-01

    Simulations of a copper laser pumped dye laser amplifier and new designs of the longitudinally pumped dye laser amplifier are presented. The simulations take the consideration of the amplified spontaneous emission (ASE). The new designs utilize a center-hole reflector instead of a dichroic mirror. The simulation results indicate that the poor spatial overlap between the pump beam and the dye beam in the transverse pumping not only reduces the laser output power, but also generates ASE strongly. The results also indicate that the longitudinal pumping is as efficient as the transverse pumping. (author)

  12. Pulse shaping amplifier (PSA) for nuclear spectroscopy system

    International Nuclear Information System (INIS)

    Lombigit, L.; Maslina Mohd Ibrahim; Nolida Yusup; Nur Aira Abdul Rahman; Yong, C.F.

    2014-01-01

    Pulse Shaping Amplifier (PSA) is an essential components in nuclear spectroscopy system. This networks have two functions; to shape the output pulse and performs noise filtering. In this paper, we describes procedure for design and development of a pulse shaping amplifier which can be used for nuclear spectroscopy system. This prototype was developed using high performance electronics devices and assembled on a FR4 type printed circuit board. Performance of this prototype was tested by comparing it with an equivalent commercial spectroscopy amplifier (Model SILENA 7611). The test results show that the performance of this prototype is comparable to the commercial spectroscopic amplifier. (author)

  13. Ligation of the Rectum with an Extracorporeal Sliding Knot Facilitating Laparoscopic Cross-Stapling

    DEFF Research Database (Denmark)

    Bulut, Orhan

    2013-01-01

    : The extracorporeal ligation of the rectum just proximal to the cut end of the rectum before applying the linear stapling stapler facilitates the procedure and requires only a few firings of the stapler during the laparoscopic rectal resections. Results: Ten patients with a median age of 72 years underwent rectal...

  14. GaN-based Power amplifiers for microwave applications

    Directory of Open Access Journals (Sweden)

    Jorge Julián Moreno-Rubio

    2016-01-01

    Full Text Available This paper presents a discussion about the design strategies of different kind of power amplifiers for RF/Microwave appli- cations, such as the tuned load power amplifier, class F, class F-1 and Doherty. Furthermore, it is shown the continuous wave characterization of the amplifiers above mentioned. A comparison between the obtained results, in terms of gain, efficiency and output power is presented.

  15. Single-mode operation of a coiled multimode fiber amplifier

    International Nuclear Information System (INIS)

    Koplow, Jeffrey P.; Kliner, Dahv A. V.; Goldberg, Lew

    2000-01-01

    We report a new approach to obtaining single-transverse-mode operation of a multimode fiber amplifier in which the gain fiber is coiled to induce significant bend loss for all but the lowest-order mode. We demonstrated this method by constructing a coiled amplifier using Yb-doped, double-clad fiber with a core diameter of 25 μm and a numerical aperture of ∼0.1 (V≅7.4) . When the amplifier was operated as an amplified-spontaneous-emission source, the output beam had an M 2 value of 1.09±0.09 ; when seeded at 1064 nm, the slope efficiency was similar to that of an uncoiled amplifier. This technique will permit scaling of pulsed fiber lasers and amplifiers to significantly higher pulse energies and peak powers and cw fiber sources to higher average powers while maintaining excellent beam quality. (c) 2000 Optical Society of America

  16. Microbial complexes levels in conventional and self-ligating brackets.

    Science.gov (United States)

    Bergamo, Ana Zilda Nazar; Nelson-Filho, Paulo; Andrucioli, Marcela Cristina Damião; do Nascimento, Cássio; Pedrazzi, Vinícius; Matsumoto, Mírian Aiko Nakane

    2017-05-01

    The aims were to evaluate the levels of bacterial species in saliva and in situ and to assess whether the design of brackets influences the risk of developing periodontal disease. Twenty patients (13.3 mean age) were bonded with self-ligating brackets and a conventional bracket. Saliva was collected before bonding and 30 and 60 days after bonding. One sample of each bracket was removed 30 and 60 days after bonding. The analysis was determined by checkerboard DNA-DNA hybridization. The data was evaluated by the non-parametric test. A significant increase in the levels of bacterial species in the saliva occurred in 15 of the 22 analyzed species. The self-ligating brackets presented the highest incidence percentages for the orange and red complexes 60 days after bonding. In situ analyses showed different patterns according to the bracket design. The levels of Campylobacter rectus showed significant differences (p = 0.011) 60 days after bonding among the three brackets; the highest values were observed in the In-Ovation®R bracket. The bracket design seems to influence the levels of bacterial species involved in periodontal disease. Considering the wide variety of bacterial species, additional studies are needed to aid in the establishment of effective protocols to prevent the development of periodontal disease during orthodontic treatment. A dynamic alteration in the oral microbiota may lead to inflammatory reactions in the supporting soft and hard tissues. The different types of brackets interfere with bacterial adherence. Bracket design should be considered in orthodontic treatment.

  17. Implantable neurotechnologies: a review of integrated circuit neural amplifiers.

    Science.gov (United States)

    Ng, Kian Ann; Greenwald, Elliot; Xu, Yong Ping; Thakor, Nitish V

    2016-01-01

    Neural signal recording is critical in modern day neuroscience research and emerging neural prosthesis programs. Neural recording requires the use of precise, low-noise amplifier systems to acquire and condition the weak neural signals that are transduced through electrode interfaces. Neural amplifiers and amplifier-based systems are available commercially or can be designed in-house and fabricated using integrated circuit (IC) technologies, resulting in very large-scale integration or application-specific integrated circuit solutions. IC-based neural amplifiers are now used to acquire untethered/portable neural recordings, as they meet the requirements of a miniaturized form factor, light weight and low power consumption. Furthermore, such miniaturized and low-power IC neural amplifiers are now being used in emerging implantable neural prosthesis technologies. This review focuses on neural amplifier-based devices and is presented in two interrelated parts. First, neural signal recording is reviewed, and practical challenges are highlighted. Current amplifier designs with increased functionality and performance and without penalties in chip size and power are featured. Second, applications of IC-based neural amplifiers in basic science experiments (e.g., cortical studies using animal models), neural prostheses (e.g., brain/nerve machine interfaces) and treatment of neuronal diseases (e.g., DBS for treatment of epilepsy) are highlighted. The review concludes with future outlooks of this technology and important challenges with regard to neural signal amplification.

  18. Analytically Sensitive Protein Detection in Microtiter Plates by Proximity Ligation with Rolling Circle Amplification.

    Science.gov (United States)

    Ebai, Tonge; Souza de Oliveira, Felipe Marques; Löf, Liza; Wik, Lotta; Schweiger, Caroline; Larsson, Anders; Keilholtz, Ulrich; Haybaeck, Johannes; Landegren, Ulf; Kamali-Moghaddam, Masood

    2017-09-01

    Detecting proteins at low concentrations in plasma is crucial for early diagnosis. Current techniques in clinical routine, such as sandwich ELISA, provide sensitive protein detection because of a dependence on target recognition by pairs of antibodies, but detection of still lower protein concentrations is often called for. Proximity ligation assay with rolling circle amplification (PLARCA) is a modified proximity ligation assay (PLA) for analytically specific and sensitive protein detection via binding of target proteins by 3 antibodies, and signal amplification via rolling circle amplification (RCA) in microtiter wells, easily adapted to instrumentation in use in hospitals. Proteins captured by immobilized antibodies were detected using a pair of oligonucleotide-conjugated antibodies. Upon target recognition these PLA probes guided oligonucleotide ligation, followed by amplification via RCA of circular DNA strands that formed in the reaction. The RCA products were detected by horseradish peroxidase-labeled oligonucleotides to generate colorimetric reaction products with readout in an absorbance microplate reader. We compared detection of interleukin (IL)-4, IL-6, IL-8, p53, and growth differentiation factor 15 (GDF-15) by PLARCA and conventional sandwich ELISA or immuno-RCA. PLARCA detected lower concentrations of proteins and exhibited a broader dynamic range compared to ELISA and iRCA using the same antibodies. IL-4 and IL-6 were detected in clinical samples at femtomolar concentrations, considerably lower than for ELISA. PLARCA offers detection of lower protein levels and increased dynamic ranges compared to ELISA. The PLARCA procedure may be adapted to routine instrumentation available in hospitals and research laboratories. © 2017 American Association for Clinical Chemistry.

  19. The Nike electron-beam-pumped KrF laser amplifiers

    International Nuclear Information System (INIS)

    Sethian, J.D.; Pawley, C.J.; Obenschain, S.P.

    1997-01-01

    Nike is a recently completed multikilojoule krypton-fluoride (KrF) laser that has been built to study the physics of direct-drive inertial confinement fusion. The two final amplifiers of the Nike laser are both electron-beam-pumped systems. This paper describes these two amplifiers, with an emphasis on the pulsed power. The smaller of the two has a 20 x 20 cm aperture, and produces an output laser beam energy in excess of 100 J. This 20 cm Amplifier uses a single 12 kJ Marx generator to inject two 300 kV, 75 kA, 140 ns flat-top electron beams into opposite sides of the laser cell. The larger amplifier in Nike has a 60 x 60 cm aperture, and amplifies the laser beam up to 5 kJ. This 60 cm amplifier has two independent electron beam systems. Each system has a 170 kJ Marx generator that produces a 670 kV, 540 kA, 240 ns flat-top electron beam. Both amplifiers are complete, fully integrated into the laser, meet the Nike system requirements, and are used routinely for laser-target experiments

  20. 47 CFR 97.315 - Certification of external RF power amplifiers.

    Science.gov (United States)

    2010-10-01

    .... (2) The amplifier was manufactured before April 28, 1978, and has been issued a marketing waiver by... that operator's station. (3) The amplifier is sold to an amateur radio operator or to a dealer, the amplifier is purchased in used condition by a dealer, or the amplifier is sold to an amateur radio operator...

  1. Pump to signal noise transfer in parametric fiber amplifiers

    DEFF Research Database (Denmark)

    Lund-Hansen, Toke; Rottwitt, Karsten; Peucheret, Christophe

    2010-01-01

    Fiber optic parametric amplifiers have been suggested due to their potential low spontaneous emission. However, by nature the parametric amplifier only work in a forward pumped configuration, which result in transfer of relative intensity noise in the pump to the signal.......Fiber optic parametric amplifiers have been suggested due to their potential low spontaneous emission. However, by nature the parametric amplifier only work in a forward pumped configuration, which result in transfer of relative intensity noise in the pump to the signal....

  2. Method for reducing snap in magnetic amplifiers

    Science.gov (United States)

    Fischer, R. L. E.; Word, J. L.

    1968-01-01

    Method of reducing snap in magnetic amplifiers uses a degenerative feedback circuit consisting of a resistor and a separate winding on a magnetic core. The feedback circuit extends amplifier range by allowing it to be used at lower values of output current.

  3. Analysis on the precision of the dimensions of self-ligating brackets.

    Science.gov (United States)

    Erduran, Rackel Hatice Milhomens Gualberto; Maeda, Fernando Akio; Ortiz, Sandra Regina Mota; Triviño, Tarcila; Fuziy, Acácio; Carvalho, Paulo Eduardo Guedes

    2016-12-01

    The present study aimed to evaluate the precision of the torque applied by 0.022" self-ligating brackets of different brands, the precision of parallelism between the inner walls of their slots, and precision of their slot height. Eighty brackets for upper central incisors of eight trademarked models were selected: Abzil, GAC, American Orthodontics, Morelli, Orthometric, Ormco, Forestadent, and Ortho Organizers. Images of the brackets were obtained using a scanning electron microscope (SEM) and these were measured using the AutoCAD 2011 software. The tolerance parameters stated in the ISO 27020 standard were used as references. The results showed that only the Orthometric, Morelli, and Ormco groups showed results inconsistent with the ISO standard. Regarding the parallelism of the internal walls of the slots, most of the models studied had results in line with the ISO prescription, except the Morelli group. In assessing bracket slot height, only the Forestadent, GAC, American Orthodontics, and Ormco groups presented results in accordance with the ISO standard. The GAC, Forestadent, and American Orthodontics groups did not differ in relation to the three factors of the ISO 27020 standard. Great variability of results is observed in relation to all the variables. © 2016 Wiley Periodicals, Inc.

  4. Amplifier Design for Proportional Ionization Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Baker, W. H.

    1950-08-24

    This paper presents the requirements of a nuclear amplifier of short resolving time, designed to accept pulses of widely varying amplitudes. Data are given which show that a proportional ionization chamber loaded with a 1,000-ohm resistor develops pulses of 0.5 microsecond duration and several volts amplitude. Results indicate that seven basic requirements are imposed on the amplifier when counting soft beta and gamma radiation in the presence of alpha particles, without absorbers. It should, (1) have a fast recovery time, (2) have a relatively good low frequency response, (3) accept pulses of widely varying heights without developing spurious pulsed, (4) have a limiting output stage, (5) preserve the inherently short rise time of the chamber, (6) minimize pulse integration, and (7) have sufficient gain to detect the weak pulses well below the chamber voltage at which continuous discharge takes place. The results obtained with an amplifier which meets these requirements is described. A formula is derived which indicates that redesign of the proportional ionization chamber might eliminate the need for an amplifier. This may be possible if the radioactive particles are collimated parallel to the collecting electrode.

  5. Power Amplifier Design for E-band Wireless System Communications

    DEFF Research Database (Denmark)

    Hadziabdic, Dzenan; Krozer, Viktor; Johansen, Tom Keinicke

    2008-01-01

    E-band wireless communications will become important as the microwave backhaul for high-speed data transmission. One of the most critical components is the front-end power amplifier in this system. The paper analyzes different technologies with potential in the E-band frequency range and present...... a power amplifier design satisfying the E-band system specifications. The designed power amplifier achieves a maximum output power of ges 20 dBm with a state-of-the-art power-added efficiency of 15%. The power is realized using InP DHBT technology. To the best of our knowledge it is the highest output...... power and efficiency reported for an InP HBT power amplifier in this frequency range. The predicted power-added efficiency is higher than that of power amplifiers based on SiGe HBT and GaAs pHEMT technologies. The design shows the capabilities of InP DHBT for power amplifier applications...

  6. A new semicustom integrated bipolar amplifier for silicon strip detectors

    International Nuclear Information System (INIS)

    Zimmerman, T.

    1989-01-01

    The QPA02 is a four channel DC coupled two stage transimpedance amplifier designed at Fermilab on a semicustom linear array (Quickchip 2S) manufactured by Tektronix. The chip was developed as a silicon strip amplifier but may have other applications as well. Each channel consists of a preamplifier and a second stage amplifier/sharper with differential output which can directly drive a transmission line (90 to 140 ohms). External bypass capacitors are the only discrete components required. QPA02 has been tested and demonstrated to be an effective silicon strip amplifier. Other applications may exist which can use this amplifier or a modified version of this amplifier. For example, another design is now in progress for a wire chamber amplifier, QPA03, to be reported later. Only a relatively small effort was required to modify the design and layout for this application. 11 figs

  7. Molecular identification of Clonorchis sinensis and discrimination with other opisthorchid liver fluke species using multiple Ligation-depended Probe Amplification (MLPA

    Directory of Open Access Journals (Sweden)

    Liang Chi

    2011-06-01

    Full Text Available Abstract Background Infections with the opisthorchid liver flukes Clonorchis sinensis, Opisthorchis viverrini, and O. felineus cause severe health problems globally, particularly in Southeast Asia. Early identification of the infection is essential to provide timely and appropriate chemotherapy to patients. Results In this study we evaluate a PCR-based molecular identification method, Multiplex Ligation-dependent Probe Amplification (MLPA, which allows rapid and specific detection of single nucleotide acid differences between Clonorchis sinensis, Opisthorchis viverrini and O. felineus. Three probe pairs were derived from the Internally Transcribed Spacer 1 (ITS1 of three opisthorchid liver flukes using a systematic phylogenetic analysis. Specific loci were detected in all three species, yielding three amplicons with 198,172 and 152 bp, respectively, while no cross reactions were observed. A panel of 66 C. sinensis isolates was screened using MLPA. All species were positively identified, and no inhibition was observed. The detection limit was 103 copies of the ITS gene for the three liver flukes, or about 60 pg genomic DNA for Clonorchis sinensis. Amplification products can be detected by electrophoresis on agarose gel or in a capillary sequencer. In addition, genomic DNA of Clonorchis sinensis in fecal samples of infected rats was positively amplified by MLPA. Conclusion The flexibility and specificity make MLPA a potential tool for specific identification of infections by opisthorchid liver flukes in endemic areas.

  8. Usefulness of real-time elastography strain ratio in the assessment of bile duct ligation-induced liver injury and the hepatoprotective effect of chitosan: an experimental animal study.

    Science.gov (United States)

    Dudea, Marina; Clichici, Simona; Olteanu, Diana Elena; Nagy, Andras; Cucoş, Maria; Dudea, Sorin

    2015-01-01

    The purpose of the study described here was to evaluate the usefulness of the elastographic strain ratio in the assessment of liver changes in an experimental animal setting and the hepatoprotective effects of chitosan. Ultrasonography and Strain Ratio calculation were performed before and after bile duct ligation (BDL) in three groups of Wistar albino rats (n = 10 animals per group): (i) rats subjected to bile duct ligation only; (ii) rats subjected to bile duct ligation and administered chitosan for 14 d; (iii) rats subjected to bile duct ligation and administered chitosan for 7 d. The results were compared with the laboratory data and pathologic findings. Strain ratios revealed an increase in liver stiffness after bile duct ligation (p liver response to injury. To the best of our knowledge, this is the first study reporting on the usefulness of the sonoelastographic liver-to-kidney strain ratio in assessing the effects of experimentally induced liver lesions. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  9. Few-mode erbium-doped fiber amplifier with photonic lantern for pump spatial mode control

    NARCIS (Netherlands)

    Lopez-Galmiche, G.; Eznaveh, Z. Sanjabi; Antonio-Lopez, J.E.; Benitez, A. M. Velazquez; Rodriguez-Asomoza, Jorge; Mondragon, J. J. Sanchez; Gonnet, C.; Sillard, P.; Li, G.; Schülzgen, A.; Okonkwo, C.M.; Amezcua Correa, R.

    2016-01-01

    We demonstrate a few-mode erbium-doped fiber amplifier employing a mode-selective photonic lantern for controlling the modal content of the pump light. Amplification of six spatial modes in a 5 m long erbium-doped fiber to x223C;6.2x2009;x2009;dBm average power is obtained while maintaining high

  10. Pulse amplifier with high 'common mode rejection'

    International Nuclear Information System (INIS)

    Ijlst, P.

    1987-01-01

    The input signal of a pulse amplifier contains large 'common-mode' signals which have to be suppressed. A transformer, especially constructed for this purpose, is described. It has been tried to optimize the signal to noise ratio of the pulse amplifier by means of noise analysis. (Auth.)

  11. Behavior of MOSFET Amplifier in Radiation Fields

    International Nuclear Information System (INIS)

    Sharshar, K.A.A.; Ashry, M.

    2000-01-01

    MOSFET type 2 N 3823 characteristics and its application as an amplifier are analyzed including the effects of gamma, electron beam 1.5 MeV 25 m A and neutron flux. The 1-V characteristics, transfer curve, and the frequency response of the amplifier, and the amplification factor(A v 0 are discussed with MOSFET circuit parameters. The drain current and the amplitude of the output signal decrease as the absorbed dose increases. The measured values of the amplified signal are attenuated by 30% and 6% after exposing the MOSFET to gamma radiation and electron beam at the same dose respectively. Also for exposure to 4x10 13 N/cm 3 neutrons decreased the measured value of the amplified signal by 73% of the initial values. The decrease in the gain of the MOSFET is due to the degradation of the transconductance. It is also noticed that percentage of the decrease depends on the type of radiation

  12. Ligation of the internal maxillary artery for intractable epistaxis. 3D imaging of internal maxillary artery using helical CT scan

    International Nuclear Information System (INIS)

    Handa, Toru; Yazin, Koji; Hirakawa, Katsuhiro; Fukushima, Noriyuki; Takumida, Masaya; Hirata, Shitau; Iguchi, Tetsuhiko; Amano, Yoshiharu

    2001-01-01

    Sever posterior epistaxis is one of the serious clinical problems. Nasal bleeding usually occurs in the anterior septal region, where it can be seen easily and controlled with topical cautery or localized packing. When the bleeding occurs in the posterior nose, it becomes a more serious problem. Many methods have been used to control posterior epistaxis. Some of these are electrocautery, posterior nasal packing, vascular ligation and therapeutic percutaneous embolization. Between 1997 and 2000, nineteen patients were admitted to our hospital because of intractable epistaxis. There were 16 male and 3 female patients whose average age was 55 years. Ten of 19 patients were hypertensive, and none of these had undergoing treatment. Five of 19 patients received maxillary artery ligation. Clinical applications of 3D imaging of the internal maxillary artery using helical CT scan were done for 5 patients. These images were helpful for planning of ligation of the internal maxillary artery. (author)

  13. Ligation of the internal maxillary artery for intractable epistaxis. 3D imaging of internal maxillary artery using helical CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Handa, Toru [Akitsu Prefectual Hospital, Hiroshima (Japan); Yazin, Koji; Hirakawa, Katsuhiro; Fukushima, Noriyuki; Takumida, Masaya; Hirata, Shitau; Iguchi, Tetsuhiko; Amano, Yoshiharu

    2001-03-01

    Sever posterior epistaxis is one of the serious clinical problems. Nasal bleeding usually occurs in the anterior septal region, where it can be seen easily and controlled with topical cautery or localized packing. When the bleeding occurs in the posterior nose, it becomes a more serious problem. Many methods have been used to control posterior epistaxis. Some of these are electrocautery, posterior nasal packing, vascular ligation and therapeutic percutaneous embolization. Between 1997 and 2000, nineteen patients were admitted to our hospital because of intractable epistaxis. There were 16 male and 3 female patients whose average age was 55 years. Ten of 19 patients were hypertensive, and none of these had undergoing treatment. Five of 19 patients received maxillary artery ligation. Clinical applications of 3D imaging of the internal maxillary artery using helical CT scan were done for 5 patients. These images were helpful for planning of ligation of the internal maxillary artery. (author)

  14. Low-noise audio amplifiers and preamplifier for use with intrinsic thermocouples

    International Nuclear Information System (INIS)

    Langner, G.C.; Sachs, R.D.; Stewart, F.L.

    1979-03-01

    Two simple, low-noise audio amplifiers and one low-noise preamplifier for use with intrinsic thermocouples were designed, built, and tested. The amplifiers and the preamplifier have different front end designs. One amplifier uses ultralow-noise operational amplifiers; the other amplifier uses a hybrid component. The preamplifier uses ultralow-noise discrete components. The amplifiers' equivalent noise inputs, at maximum gain, are 4.09 nV and 50 nV; the preamplifier's input is 4.05 μV. Their bandwidths are 15 600 Hz, 550 Hz, and 174 kHz, respectively. the amplifiers' equivalent noise inputs were measured from approx. 0 to 100 Hz, whereas the preamplifier's equivalent noise input was measured from approx. 0 to 174 kHz

  15. Agmatine attenuates neuropathic pain in sciatic nerve ligated rats: modulation by hippocampal sigma receptors.

    Science.gov (United States)

    Kotagale, Nandkishor Ramdas; Shirbhate, Saurabh Haridas; Shukla, Pradeep; Ugale, Rajesh Ramesh

    2013-08-15

    Present study investigated the influence of the sigma (σ₁ and σ₂) receptors within hippocampus on the agmatine induced antinociception in neuropathic rats. Animals were subjected to sciatic nerve ligation for induction of neuropathic pain and observed the paw withdrawal latency in response to thermal hyperalgesia, cold allodynia and the mechanical hyperalgesia. Intrahippocampal (i.h.) as well as intraperitoneal (i.p.) administration of agmatine attenuated neuropathic pain in sciatic nerve ligated rats. Intrahippocampal administration of σ₁ agonist (+)-pentazocine or σ₂ agonist PB28 sensitized whereas, σ₁ antagonist BD1063 or σ₂ antagonist SM21 potentiated antinociceptive effect of agmatine. The behavioral effects correlated with hippocampal tumor necrosis factor-α (TNF-α) levels observed by western blot analysis. These results suggest that both the σ₁ and σ₂ receptor subunits within hippocampus play an important role in antinociceptive action of agmatine against neuropathic pain. © 2013 Elsevier B.V. All rights reserved.

  16. Dentoalveolar mandibular changes with self-ligating versus conventional bracket systems: A CBCT and dental cast study

    Science.gov (United States)

    de Almeida, Marcio Rodrigues; Futagami, Cristina; Conti, Ana Cláudia de Castro Ferreira; Oltramari-Navarro, Paula Vanessa Pedron; Navarro, Ricardo de Lima

    2015-01-01

    OBJECTIVE: The aim of the present study was to compare dentoalveolar changes in mandibular arch, regarding transversal measures and buccal bone thickness, in patients undergoing the initial phase of orthodontic treatment with self-ligating or conventional bracket systems. METHODS: A sample of 25 patients requiring orthodontic treatment was assessed based on the bracket type. Group 1 comprised 13 patients bonded with 0.022-in self-ligating brackets (SLB). Group 2 included 12 patients bonded with 0.022-in conventional brackets (CLB). Cone-beam computed tomography (CBCT) scans and a 3D program (Dolphin) assessed changes in transversal width of buccal bone (TWBB) and buccal bone thickness (BBT) before (T1) and 7 months after treatment onset (T2). Measurements on dental casts were performed using a digital caliper. Differences between and within groups were analyzed by Student's t-test; Pearson correlation coefficient was also calculated. RESULTS: Significant mandibular expansion was observed for both groups; however, no significant differences were found between groups. There was significant decrease in mandibular buccal bone thickness and transversal width of buccal bone in both groups. There was no significant correlation between buccal bone thickness and dental arch expansion. CONCLUSIONS: There were no significant differences between self-ligating brackets and conventional brackets systems regarding mandibular arch expansion and changes in buccal bone thickness or transversal width of buccal bone. PMID:26154456

  17. Total chemical synthesis of histones and their analogs, assisted by native chemical ligation and palladium complexes.

    Science.gov (United States)

    Maity, Suman Kumar; Jbara, Muhammad; Mann, Guy; Kamnesky, Guy; Brik, Ashraf

    2017-11-01

    Chemical synthesis of histones allows precise control of the installation of post-translational modifications via the coupling of derivatized amino acids. Shortcomings of other approaches for obtaining modified histones for epigenetic studies include heterogeneity of the obtained product and difficulties in incorporating multiple modifications on the same histone. In this protocol, unprotected peptide fragments are prepared by Fmoc solid-phase synthesis and coupled in aqueous buffers via native chemical ligation (NCL; in NCL, a peptide bond is formed between a peptide with an N-terminal Cys and another peptide having a C-terminal thioester). This task is challenging, with obstacles relating to the preparation and ligation of hydrophobic peptides, as well as the requirement for multiple purification steps due to protecting-group manipulations during the polypeptide assembly process. To address this, our approach uses an easily removable solubilizing tag for the synthesis and ligation of hydrophobic peptides, as well as a more efficient and better-yielding method to remove Cys-protecting groups that uses palladium chemistry (specifically [Pd(allyl)Cl] 2 and PdCl 2 complexes). The utility of this approach is demonstrated in the syntheses of ubiquitinated H2B at Lys34, phosphorylated H2A at Tyr57 and unmodified H4. Each of these analogs can be prepared in milligram quantities within ∼20-30 d.

  18. Injection sclerotherapy versus rubber band ligation for second degree hemorrhoids

    International Nuclear Information System (INIS)

    Nasir, M.A.; Masroor, R.; Arfar, Y.; Sarwar, S.; Butt, Q.

    2017-01-01

    Objective: To compare the efficacy of injections Sclerotherapy (IST) and rubber band ligation (RBL) for the treatment of 2nd degree haemorrhoids in terms of improvement in symptoms severity score (SS score) in OPD patients. Study Design: Randomized controlled trial. Place and Duration of Study: It was conducted in surgical OPD of CMH Kohat, from 15th October 2010 to 10th April 2011 Material and Methods: A total of 116 patients with symptomatic 2nd degree haemorrhoids were randomly divided into two groups, RBL and IST (58 patients each) respectively and a baseline symptoms severity score was noted for each patient. Patients in RBL group were treated with RBL while in IST group were treated with IST. The outcome measures were relief of symptoms and improvement in SS score. Results: In RBL group, baseline SS score was 4.67 +- 2.01 which reduced to final mean SS score of 1.34 +- 0.96 whereas in IST group the baseline SS score was of 4.31 +- 2.13 which reduced to a final mean SS score of 1.6 +- 0.97. 44 (75.95%) patients had complete recovery and control of bleeding in RBL group; whereas in IST group 32 (55.1%) of the patients had this response by the end of two weeks. Conclusion: Rubber band ligation was found to have better patient outcomes as compared to injections sclerotherapy in treatment of 2nd degree hemorrhoids. (author)

  19. Free-electron laser system with Raman amplifier outcoupling

    Energy Technology Data Exchange (ETDEWEB)

    Linford, G.J.

    1988-05-03

    A free-electron laser system is described comprising: a free-electron laser pump beam generator producing a high-power optical output beam in a vacuum environement; a Raman amplifier cell located in the path of the output beam from the pump beam generator; means for generating and introducing a Stokes seed beam into the Raman amplifier cell, a pair of gaseous windows through which the output beam enters and leaves the Raman amplifier cell, each window having a stream of gas moving continuously in a direction generally perpendicular to the beam; and a mirror positioned in the path of the output beam from the Raman amplifier, the mirror functioning to reflect and further direct the output beam, but not the unwanted spectral components.

  20. Modeling and design techniques for RF power amplifiers

    CERN Document Server

    Raghavan, Arvind; Laskar, Joy

    2008-01-01

    The book covers RF power amplifier design, from device and modeling considerations to advanced circuit design architectures and techniques. It focuses on recent developments and advanced topics in this area, including numerous practical designs to back the theoretical considerations. It presents the challenges in designing power amplifiers in silicon and helps the reader improve the efficiency of linear power amplifiers, and design more accurate compact device models, with faster extraction routines, to create cost effective and reliable circuits.

  1. Efficient trigger signal generation from wasted backward amplified stimulated emission at optical amplifiers for optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Kim Seung Taek

    2015-01-01

    Full Text Available This paper propose an optical structure to generate trigger signals for optical coherence tomography (OCT using backward light which is usually disposed. The backward light is called backward amplified stimulated emission generated from semiconductor optical amplifier (SOA when using swept wavelength tunable laser (SWTL. A circulator is applied to block undesirable lights in the SWTL instead of an isolator in common SWTL. The circulator also diverts backward amplified spontaneous lights, which finally bring out trigger signals for a high speed digitizer. The spectra of the forward lights at SOA and the waveform of the backward lights were measured to check the procedure of the trigger formation in the experiment. The results showed that the trigger signals from the proposed SWTL with the circulator was quite usable in OCT.

  2. Amplifying genetic logic gates.

    Science.gov (United States)

    Bonnet, Jerome; Yin, Peter; Ortiz, Monica E; Subsoontorn, Pakpoom; Endy, Drew

    2013-05-03

    Organisms must process information encoded via developmental and environmental signals to survive and reproduce. Researchers have also engineered synthetic genetic logic to realize simpler, independent control of biological processes. We developed a three-terminal device architecture, termed the transcriptor, that uses bacteriophage serine integrases to control the flow of RNA polymerase along DNA. Integrase-mediated inversion or deletion of DNA encoding transcription terminators or a promoter modulates transcription rates. We realized permanent amplifying AND, NAND, OR, XOR, NOR, and XNOR gates actuated across common control signal ranges and sequential logic supporting autonomous cell-cell communication of DNA encoding distinct logic-gate states. The single-layer digital logic architecture developed here enables engineering of amplifying logic gates to control transcription rates within and across diverse organisms.

  3. Identification and DNA fingerprinting of Legionella strains by randomly amplified polymorphic DNA analysis.

    OpenAIRE

    Bansal, N S; McDonell, F

    1997-01-01

    The randomly amplified polymorphic DNA (RAPD) technique was used in the development of a fingerprinting (typing) and identification protocol for Legionella strains. Twenty decamer random oligonucleotide primers were screened for their discriminatory abilities. Two candidate primers were selected. By using a combination of these primers, RAPD analysis allowed for the differentiation between all different species, between the serogroups, and further differentiation between subtypes of the same ...

  4. Establishment of a rat model of portal vein ligation combined with in situ splitting.

    Science.gov (United States)

    Yao, Libin; Li, Chonghui; Ge, Xinlan; Wang, Hongdong; Xu, Kesen; Zhang, Aiqun; Dong, Jiahong

    2014-01-01

    Portal vein ligation (PVL) combined with in situ splitting (ISS) has been shown to induce remarkable liver regeneration in patients. The purpose of this study was to establish a model of PVL+ISS in rats for exploring the possible mechanisms of liver regeneration using these techniques. Rats were randomly assigned to three experimental groups: selective PVL, selective PVL+ISS and sham operation. The hepatic regeneration rate (HRR), Ki-67, liver biochemical determinations and histopathology were assessed at 24, 48, and 72 h and 7 days after the operation. The microcirculation of the median lobes before and after ISS was examined by laser speckle contrast imaging. Meanwhile, cytokines such as TNF-α, IL-6, HGF and HSP70 in regenerating liver lobes at 24 h was investigated by RT-PCR and ELISA. The HRR of PVL+ISS was much higher than that of the PVL at 72 h and 7 days after surgery (pprotein levels of TNF-α, IL-6 and HGF in regenerating liver lobes were higher in the PVL+ISS than the PVL alone. The higher HRR in the PVL+ISS compared with the PVL confirmed that we had successfully established a PVL+ISS model in rats. The possible mechanisms included the reduced microcirculation blood perfusion of the left median lobe and up-regulation of cytokines in the regenerating lobes after ISS.

  5. SPS RF System Amplifier plant

    CERN Multimedia

    1977-01-01

    The picture shows a 2 MW, 200 MHz amplifier plant with feeder lines. The main RF-system of the SPS comprises four cavities: two of 20 m length and two of 16.5 m length. They are all installed in one long straight section (LSS 3). These cavities are of the travelling-wave type operating at a centre frequency of 200.2 MHz. They are wideband, filling time about 700 ns and untuned. The power amplifiers, using tetrodes are installed in a surface building 200 m from the cavities. Initially only two cavities were installed, a third cavity was installed in 1978 and a forth one in 1979. The number of power amplifiers was also increased: to the first 2 MW plant a second 2 MW plant was added and by end 1979 there were 8 500 kW units combined in pairs to feed each of the 4 cavities with up to about 1 MW RF power, resulting in a total accelerating voltage of about 8 MV. See also 7412016X, 7412017X, 7411048X.

  6. [Study on sequence characterized amplified region (SCAR) markers of Cornus officinalis].

    Science.gov (United States)

    Chen, Suiqing; Lu, Xiaolei; Wang, Lili

    2011-05-01

    To establish sequence characterized amplified region markers of Cornus officinalis and provide a scientific basis for molecular identification of C. officinalis. The random primer was screened through RAPD to obtain specific RAPD marker bands. The RAPD marker bands were separated, extracted, cloned and sequenced. Both ends of the sequence of RAPD marker bands were determined. A pair of specific primers was designed for conventional PCR reaction, and SCAR marker was acquired. Four pairs of primers were designed based on the sequence of RAPD marker bands. The DNA of the seven varieties of C. officinalis was amplified by using YST38 and YST43 primer. The results showed that seven varieties of C. officinalis were able to produce a single PCR product. It was an effective way to identify C. officinalis. The varieties with cylindrical and long-pear shape fruits amplified by YST38 showed a specific band, which could be used as the evidence of variety identification. Seven varieties of C. oficinalis were amplified by using primer YST39. But the size of band of the variety with spindly shape fruit (35,0400 bp) was about 300 bp, which was shorter than those of the variety with the other shape fruits of C. officinalis (650-700 bp). The variety with the spindly shape fruit could be identified through this difference. The primer YST92 could produce a fragment from 600-700 bp in the varieties with cylindrical and long-pear shape fruits, a fragment from 200-300 bp in the varieties with oval and short-cylindrical shape fruits and had no fragment in the varieties with long cylindrical, elliptic and short-pear shape fruits, which could be used to select the different shapes of C. officinalis. SCAR mark is established and can be used as the basis for breeding and distinguishing the verieties of C. officinalis.

  7. Photoelastic analysis of stress generated by wires when conventional and self-ligating brackets are used: A pilot study

    Directory of Open Access Journals (Sweden)

    Guilherme Caiado Sobral

    2014-10-01

    Full Text Available OBJECTIVE: By means of a photoelastic model, this study analyzed the stress caused on conventional and self-ligating brackets with expanded arch wires. METHOD: Standard brackets were adhered to artificial teeth and a photoelastic model was prepared using the Interlandi 19/12 diagram as base. Successive activations were made with 0.014-in and 0.018-in rounded cross section Nickel-Titanium wires (NiTi and 0.019 x 0.025-in rectangular stainless steel wires all of which made on 22/14 Interlandi diagram. The model was observed on a plane polariscope - in a dark field microscope configuration - and photographed at each exchange of wire. Then, they were replaced by self-ligating brackets and the process was repeated. Analysis was qualitative and observed stress location and pattern on both models analyzed. CONCLUSIONS: Results identified greater stress on the region of the apex of premolars in both analyzed models. Upon comparing the stress between models, a greater amount of stress was found in the model with conventional brackets in all of its wires. Therefore, the present pilot study revealed that alignment of wires in self-ligating brackets produced lower stress in periodontal tissues in expansive mechanics.

  8. Wideband pulse amplifiers for the NECTAr chip

    International Nuclear Information System (INIS)

    Sanuy, A.; Delagnes, E.; Gascon, D.; Sieiro, X.; Bolmont, J.; Corona, P.; Feinstein, F.; Glicenstein, J-F.; Naumann, C.L.; Nayman, P.; Ribó, M.

    2012-01-01

    The NECTAr collaboration's FE option for the camera of the CTA is a 16 bits and 1–3 GS/s sampling chip based on analog memories including most of the readout functions. This works describes the input amplifiers of the NECTAr ASIC. A fully differential wideband amplifier, with voltage gain up to 20 V/V and a BW of 400 MHz. As it is impossible to design a fully differential OpAmp with an 8 GHz GBW product in a 0.35 CMOS technology, an alternative implementation based on HF linearized transconductors is explored. The output buffer is a class AB miller operational amplifier, with special non-linear current boost.

  9. Wideband pulse amplifiers for the NECTAr chip

    Science.gov (United States)

    Sanuy, A.; Delagnes, E.; Gascon, D.; Sieiro, X.; Bolmont, J.; Corona, P.; Feinstein, F.; Glicenstein, J.-F.; Naumann, C. L.; Nayman, P.; Ribó, M.; Tavernet, J.-P.; Toussenel, F.; Vincent, P.; Vorobiov, S.

    2012-12-01

    The NECTAr collaboration's FE option for the camera of the CTA is a 16 bits and 1-3 GS/s sampling chip based on analog memories including most of the readout functions. This works describes the input amplifiers of the NECTAr ASIC. A fully differential wideband amplifier, with voltage gain up to 20 V/V and a BW of 400 MHz. As it is impossible to design a fully differential OpAmp with an 8 GHz GBW product in a 0.35 CMOS technology, an alternative implementation based on HF linearized transconductors is explored. The output buffer is a class AB miller operational amplifier, with special non-linear current boost.

  10. High-power piezo drive amplifier for large stack and PFC applications

    Science.gov (United States)

    Clingman, Dan J.; Gamble, Mike

    2001-08-01

    This paper describes the continuing development of Boeing High Power Piezo Drive Amplifiers. Described is the development and testing of a 1500 Vpp, 8 amp switching amplifier. This amplifier is used to drive a piezo stack driven rotor blade trailing edge flap on a full size helicopter. Also discuss is a switching amplifier designed to drive a Piezo Fiber Composite (PFC) active twist rotor blade. This amplifier was designed to drive the PFC material at 2000 Vpp and 0.5 amps. These amplifiers recycle reactive energy, allowing for a power and weight efficient amplifier design. This work was done in conjunction with the DARPA sponsored Phase II Smart Rotor Blade program and the NASA Langley Research Center sponsored Active Twist Rotor (ATR) blade program.

  11. Traveling-Wave Tube Amplifier for THz Frequencies

    DEFF Research Database (Denmark)

    Kotiranta, Mikko; Krozer, Viktor; Zhurbenko, Vitaliy

    tubes and gas lasers, but the ones available are too expensive or large for many applications. This work is related to the European project OPTHER (Optically driven terahertz amplifiers) which aims to realise a compact, powerful and efficient vacuum tube amplifier for the frequency range of 0.3 – 2...

  12. Optimal conditions to use Pfu exo(-) DNA polymerase for highly efficient ligation-mediated polymerase chain reaction protocols.

    Science.gov (United States)

    Angers, M; Cloutier, J F; Castonguay, A; Drouin, R

    2001-08-15

    Ligation-Mediated Polymerase Chain Reaction (LMPCR) is the most sensitive sequencing technique available to map single-stranded DNA breaks at the nucleotide level of resolution using genomic DNA. LMPCR has been adapted to map DNA damage and reveal DNA-protein interactions inside living cells. However, the sequence context (GC content), the global break frequency and the current combination of DNA polymerases used in LMPCR affect the quality of the results. In this study, we developed and optimized an LMPCR protocol adapted for Pyrococcus furiosus exo(-) DNA polymerase (Pfu exo(-)). The relative efficiency of Pfu exo(-) was compared to T7-modified DNA polymerase (Sequenase 2.0) at the primer extension step and to Thermus aquaticus DNA polymerase (Taq) at the PCR amplification step of LMPCR. At all break frequencies tested, Pfu exo(-) proved to be more efficient than Sequenase 2.0. During both primer extension and PCR amplification steps, the ratio of DNA molecules per unit of DNA polymerase was the main determinant of the efficiency of Pfu exo(-), while the efficiency of Taq was less affected by this ratio. Substitution of NaCl for KCl in the PCR reaction buffer of Taq strikingly improved the efficiency of the DNA polymerase. Pfu exo(-) was clearly more efficient than Taq to specifically amplify extremely GC-rich genomic DNA sequences. Our results show that a combination of Pfu exo(-) at the primer extension step and Taq at the PCR amplification step is ideal for in vivo DNA analysis and DNA damage mapping using LMPCR.

  13. Long-term safety of left renal vein division and ligation to expedite complex abdominal aortic surgery.

    Science.gov (United States)

    Samson, Russell H; Lepore, Michael R; Showalter, David P; Nair, Deepak G; Lanoue, Julien B

    2009-09-01

    Left renal vein division and ligation (LRVDAL) is performed to facilitate complex abdominal aortic surgery. Surgeons restore continuity of the vein due to concern that ligation could cause renal compromise or hematuria. However, we report the short and long-term safety of left renal vein division and ligation. Between 1992 and 2007, we divided the left renal vein in 56 patients (40 males, 16 females) ages 57 to 84 (average 74-years-old) who were treated for aortic occlusive disease (9) or abdominal aortic aneurysm (47). Patients requiring concomitant renal artery reconstruction were excluded from this review. Suprarenal cross-clamp was used in 51 patients with temporary vessel-loop control of the renal arteries. Creatinine (Cr) and glomerular filtration rates (eGFR) were measured pre-, post-, and long-term after surgery. Outpatient records of all patients that had survived more than 12 months were also reviewed in order to evaluate the late effects on renal function or symptoms possibly related to LRVDAL. Median procedure duration was 157 (61-375) minutes. Median cross-clamp time was 16 (10-45) minutes. Median intensive care unit (ICU) and hospital length of stays were 2 (1-11) days and 7 (4-58) days, respectively. There were no deaths. There were no complications directly related to renal vein ligation. Hematuria, seen in 2 patients, was a result of traumatic insertion of a Foley catheter. Median pre-op and discharge Cr levels were 1.1 mg/dL (0.7-2.4 mg/dL) and 1.1 mg/dL (0.6-2.1 mg/dL), respectively (P 2.0 mg/dL remained unchanged post-op. Only 2 patients with a Cr of 2.0 mg/dL and both returned to normal by day 3 post-op. Thirty-six patients have been followed for more than a year (median 34.5 months, maximum 144 months) and Cr has remained stable in all but 2 patients. These 2 patients, both with a pre-op Cr of 1.5 mg/dL, subsequently developed Cr levels of 2.1 mg/dL and 2.4 mg/dL but maintained baseline Cr levels for 25 and 34 months, respectively, before

  14. Modified Functional Superficial Parotidectomy With Ligation of the Major Branch of the Parotid Duct Extending to the Superficial Lobe.

    Science.gov (United States)

    Chang, Jung Woo; Leem, Soo Seong; Choi, Hwan Jun; Lee, Jang Hyun

    2017-05-01

    A functional superficial parotidectomy can maintain salivary function by preserving the Stensen duct. However, this technique still brings the possibility of salivary leakage, because major branches of the parotid duct from the resected site do not get ligated. To reduce this complication, this study introduces a modified technique with major branch ligation. From December 2008 to February 2015, 14 patients who underwent superficial parotidectomy were divided into 2 groups. Group A was treated with the modified functional superficial parotidectomy involving the major branch between the superficial lobe and parotid duct. Group B was treated with the conventional superficial parotidectomy without involving the major branch of the parotid duct. The clinical complications, period of Hemovac usage, and surgical duration were noted in each group. Two of 8 patients in group A had a major branch from Stensen duct that was ligated, and there was no evidence of salivary leakage or sialocele in any of the patients of group A, whereas group B contained 2 cases of salivary leakage, one of which became sialocele. Group A had a significantly longer Hemovac maintenance period than group B (P < 0.05), and the duration of surgery was also significantly different between the 2 groups (P < 0.05). Because a solitary major branch of the main parotid duct occasionally extends toward the superficial lobe, our modified technique-functional superficial parotidectomy with ligation of the major branch toward the superficial lobe-is a useful option for treatment of a benign parotid mass in such cases.

  15. Introduction to RF power amplifier design and simulation

    CERN Document Server

    Eroglu, Abdullah

    2015-01-01

    Introduction to RF Power Amplifier Design and Simulation fills a gap in the existing literature by providing step-by-step guidance for the design of radio frequency (RF) power amplifiers, from analytical formulation to simulation, implementation, and measurement. Featuring numerous illustrations and examples of real-world engineering applications, this book:Gives an overview of intermodulation and elaborates on the difference between linear and nonlinear amplifiersDescribes the high-frequency model and transient characteristics of metal-oxide-semiconductor field-effect transistorsDetails activ

  16. Distributed CMOS Bidirectional Amplifiers Broadbanding and Linearization Techniques

    CERN Document Server

    El-Khatib, Ziad; Mahmoud, Samy A

    2012-01-01

    This book describes methods to design distributed amplifiers useful for performing circuit functions such as duplexing, paraphrase amplification, phase shifting power splitting and power combiner applications.  A CMOS bidirectional distributed amplifier is presented that combines for the first time device-level with circuit-level linearization, suppressing the third-order intermodulation distortion. It is implemented in 0.13μm RF CMOS technology for use in highly linear, low-cost UWB Radio-over-Fiber communication systems. Describes CMOS distributed amplifiers for optoelectronic applications such as Radio-over-Fiber systems, base station transceivers and picocells; Presents most recent techniques for linearization of CMOS distributed amplifiers; Includes coverage of CMOS I-V transconductors, as well as CMOS on-chip inductor integration and modeling; Includes circuit applications for UWB Radio-over-Fiber networks.

  17. Resistor-less charge sensitive amplifier for semiconductor detectors

    Energy Technology Data Exchange (ETDEWEB)

    Pelczar, K., E-mail: krzysztof.pelczar@doctoral.uj.edu.pl; Panas, K.; Zuzel, G.

    2016-11-01

    A new concept of a Charge Sensitive Amplifier without a high-value resistor in the feedback loop is presented. Basic spectroscopic parameters of the amplifier coupled to a coaxial High Purity Germanium detector (HPGe) are discussed. The amplifier signal input is realized with an n-channel J-FET transistor. The feedback capacitor is discharged continuously by the second, forward biased n-channel J-FET, driven by an RC low–pass filter. Both the analog—with a standard spectroscopy amplifier and a multi-channel analyzer—and the digital—by applying a Flash Analog to Digital Converter—signal readouts were tested. The achieved resolution in the analog and the digital readouts was 0.17% and 0.21%, respectively, at the Full Width at Half Maximum of the registered {sup 60}Co 1332.5 keV gamma line.

  18. Molecular Recognition of Cobalt(III)-ligated Peptides by Serine Proteases: The Role of Electrostatic Effects

    DEFF Research Database (Denmark)

    Bagger, Sven; Wagner, Kim

    1998-01-01

    pancreatic trypsin, and proteinase K from Tritirachium album was examined. The efficiency of the substrates was assessed by kinetic measurement of the partition between aminolysis and hydrolysis. The results are discussed with special reference to coulombic interactions between the metal-ligated substrates...

  19. A prospective study of outcome from rubber band ligation of piles.

    Science.gov (United States)

    Longman, R J; Thomson, W H F

    2006-02-01

    With the recent introduction of stapled anopexy it is timely to review the benefits of existing treatment options for piles. This study investigates the effectiveness and safety of rubber band ligation (RBL) of piles in the outpatient setting. Two hundred and fifty-two consecutive patients referred with piles in an 18-month period were studied prospectively. In those patients deemed suitable for banding of piles, data were collected on symptoms, proctoscopic appearance and degree of piles. Short and long-term outcome data were recorded for success of treatment and complications. Of 203 patients considered suitable and who attended for RBL, 176 kept their follow-up appointment. One hundred and forty-eight (84%) had been rendered symptom-free. A third of patients, however, had proctoscopic evidence of persistent piles, whilst in half of those patients with continuing symptoms the anal cushions appeared normal. Six (3%) patients had suffered a complication. Long-term follow-up by questionnaire found that 44% of respondents remained asymptomatic at a median of 46 months from banding. Six (5%) of 117 responders to the questionnaire had, though previously normal, suffered a postbanding impairment of continence. Most patients with piles of any degree can be safely managed by rubber band ligation, but return of symptoms in the long term affects more than half of patients treated.

  20. Rac-mediated Stimulation of Phospholipase Cγ2 Amplifies B Cell Receptor-induced Calcium Signaling*♦

    Science.gov (United States)

    Walliser, Claudia; Tron, Kyrylo; Clauss, Karen; Gutman, Orit; Kobitski, Andrei Yu.; Retlich, Michael; Schade, Anja; Röcker, Carlheinz; Henis, Yoav I.; Nienhaus, G. Ulrich; Gierschik, Peter

    2015-01-01

    The Rho GTPase Rac is crucially involved in controlling multiple B cell functions, including those regulated by the B cell receptor (BCR) through increased cytosolic Ca2+. The underlying molecular mechanisms and their relevance to the functions of intact B cells have thus far remained unknown. We have previously shown that the activity of phospholipase Cγ2 (PLCγ2), a key constituent of the BCR signalosome, is stimulated by activated Rac through direct protein-protein interaction. Here, we use a Rac-resistant mutant of PLCγ2 to functionally reconstitute cultured PLCγ2-deficient DT40 B cells and to examine the effects of the Rac-PLCγ2 interaction on BCR-mediated changes of intracellular Ca2+ and regulation of Ca2+-regulated and nuclear-factor-of-activated-T-cell-regulated gene transcription at the level of single, intact B cells. The results show that the functional Rac-PLCγ2 interaction causes marked increases in the following: (i) sensitivity of B cells to BCR ligation; (ii) BCR-mediated Ca2+ release from intracellular stores; (iii) Ca2+ entry from the extracellular compartment; and (iv) nuclear translocation of the Ca2+-regulated nuclear factor of activated T cells. Hence, Rac-mediated stimulation of PLCγ2 activity serves to amplify B cell receptor-induced Ca2+ signaling. PMID:25903139

  1. Gyrocon: a deflection-modulated, high-power microwave amplifier

    International Nuclear Information System (INIS)

    Tallerico, P.J.

    1977-10-01

    A large-signal, relativistic theory of the electron-field interaction in a new class of microwave amplifiers is presented and applied to the analysis of a high-power, 450-MHz amplifier for accelerator applications. The analysis indicates that electronic efficiencies in excess of 90 percent are obtainable and that overall efficiencies of 90 percent are possible. The amplifier is unique in several respects; the electron velocity is perpendicular to the circuit energy flow, the device uses a fast-wave circuit, and the electron beam is deflection modulated

  2. External Peltier Cooler For Low-Noise Amplifier

    Science.gov (United States)

    Soper, Terry A.

    1990-01-01

    Inexpensive Peltier-effect cooling module made of few commercially available parts used to reduce thermal noise in microwave amplifier. Retrofitted to almost any microwave low-noise amplifier or receiver preamplifier used in communication, telemetry, or radar. Includes copper or aluminum cold plate held tightly against unit to be cooled by strap-type worm-gear clamps.

  3. Efficiency Optimization in Class-D Audio Amplifiers

    DEFF Research Database (Denmark)

    Yamauchi, Akira; Knott, Arnold; Jørgensen, Ivan Harald Holger

    2015-01-01

    This paper presents a new power efficiency optimization routine for designing Class-D audio amplifiers. The proposed optimization procedure finds design parameters for the power stage and the output filter, and the optimum switching frequency such that the weighted power losses are minimized under...... the given constraints. The optimization routine is applied to minimize the power losses in a 130 W class-D audio amplifier based on consumer behavior investigations, where the amplifier operates at idle and low power levels most of the time. Experimental results demonstrate that the optimization method can...... lead to around 30 % of efficiency improvement at 1.3 W output power without significant effects on both audio performance and the efficiency at high power levels....

  4. Wideband pulse amplifiers for the NECTAr chip

    Energy Technology Data Exchange (ETDEWEB)

    Sanuy, A., E-mail: asanuy@ecm.ub.es [Dept. AM i Dept. ECM, Institut de Ciencies del Cosmos (ICC), Universitat de Barcelona. Marti i Franques 1, E08028, Barcelona (Spain); Delagnes, E. [IRFU/DSM/CEA, CE-Saclay, Bat. 141 SEN Saclay, F-91191, Gif-sur-Yvette (France); Gascon, D. [Dept. AM i Dept. ECM, Institut de Ciencies del Cosmos (ICC), Universitat de Barcelona. Marti i Franques 1, E08028, Barcelona (Spain); Sieiro, X. [Departament d' Electronica, Universitat de Barcelona. Marti i Franques 1, E08028, Barcelona (Spain); Bolmont, J.; Corona, P. [LPNHE, Universite Paris VI and Universite Paris VII and IN2P3/CNRS, Barre 12-22, 1er etage, 4 place Jussieu, 75252 Paris (France); Feinstein, F. [LUPM, Universite Montpellier II and IN2P3/CNRS, CC072, bat. 13, place Eugene Bataillon, 34095 Montpellier (France); Glicenstein, J-F. [IRFU/DSM/CEA, CE-Saclay, Bat. 141 SEN Saclay, F-91191, Gif-sur-Yvette (France); Naumann, C.L.; Nayman, P. [LPNHE, Universite Paris VI and Universite Paris VII and IN2P3/CNRS, Barre 12-22, 1er etage, 4 place Jussieu, 75252 Paris (France); Ribo, M. [Dept. AM i Dept. ECM, Institut de Ciencies del Cosmos (ICC), Universitat de Barcelona. Marti i Franques 1, E08028, Barcelona (Spain); and others

    2012-12-11

    The NECTAr collaboration's FE option for the camera of the CTA is a 16 bits and 1-3 GS/s sampling chip based on analog memories including most of the readout functions. This works describes the input amplifiers of the NECTAr ASIC. A fully differential wideband amplifier, with voltage gain up to 20 V/V and a BW of 400 MHz. As it is impossible to design a fully differential OpAmp with an 8 GHz GBW product in a 0.35 CMOS technology, an alternative implementation based on HF linearized transconductors is explored. The output buffer is a class AB miller operational amplifier, with special non-linear current boost.

  5. The Dynamics of Semiconductor Optical Amplifiers – Modeling and Applications

    DEFF Research Database (Denmark)

    Mørk, Jesper; Nielsen, Mads Lønstrup; Berg, Tommy Winther

    2003-01-01

    The importance of semiconductor optical amplifiers is discussed. A semiconductor optical amplifier (SOA) is a semiconductor laser with anti-reflection coated facets that amplifies an injected light signal by means of stimulated emission. SOAs have a number of unique properties that open up...

  6. Noise and saturation properties of semiconductor quantum dot optical amplifiers

    DEFF Research Database (Denmark)

    Berg, Tommy Winther; Mørk, Jesper

    2002-01-01

    We present a detailed theoretical analysis of quantum dot optical amplifiers. Due to the presence of a reservoir of wetting layer states, the saturation and noise properties differ markedly from bulk or QW amplifiers and may be significantly improved.......We present a detailed theoretical analysis of quantum dot optical amplifiers. Due to the presence of a reservoir of wetting layer states, the saturation and noise properties differ markedly from bulk or QW amplifiers and may be significantly improved....

  7. Manhattan equation for the operational amplifier

    OpenAIRE

    Mishonov, Todor M.; Danchev, Victor I.; Petkov, Emil G.; Gourev, Vassil N.; Dimitrova, Iglika M.; Varonov, Albert M.

    2018-01-01

    A differential equation relating the voltage at the output of an operational amplifier $U_0$ and the difference between the input voltages ($U_{+}$ and $U_{-}$) has been derived. The crossover frequency $f_0$ is a parameter in this operational amplifier master equation. The formulas derived as a consequence of this equation find applications in thousands of specifications for electronic devices but as far as we know, the equation has never been published. Actually, the master equation of oper...

  8. AIDA: A 16-channel amplifier ASIC to read out the advanced implantation detector array for experiments in nuclear decay spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Braga, D. [STFC Rutherford Appleton Laboratory, Didcot, OX11 0QX (United Kingdom); Coleman-Smith, P. J. [STFC Daresbury Laboratory, Warrington WA4 4AD (United Kingdom); Davinson, T. [Dept. of Physics and Astronomy, Univ. of Edinburgh, Edinburgh EH9 3JZ (United Kingdom); Lazarus, I. H. [STFC Daresbury Laboratory, Warrington WA4 4AD (United Kingdom); Page, R. D. [Dept. of Physics, Univ. of Liverpool, Oliver Lodge Laboratory, Liverpool L69 7ZE (United Kingdom); Thomas, S. [STFC Rutherford Appleton Laboratory, Didcot, OX11 0QX (United Kingdom)

    2011-07-01

    We have designed a read-out ASIC for nuclear decay spectroscopy as part of the AIDA project - the Advanced Implantation Detector Array. AIDA will be installed in experiments at the Facility for Antiproton and Ion Research in GSI, Darmstadt. The AIDA ASIC will measure the signals when unstable nuclei are implanted into the detector, followed by the much smaller signals when the nuclei subsequently decay. Implant energies can be as high as 20 GeV; decay products need to be measured down to 25 keV within just a few microseconds of the initial implants. The ASIC uses two amplifiers per detector channel, one covering the 20 GeV dynamic range, the other selectable over a 20 MeV or 1 GeV range. The amplifiers are linked together by bypass transistors which are normally switched off. The arrival of a large signal causes saturation of the low-energy amplifier and a fluctuation of the input voltage, which activates the link to the high-energy amplifier. The bypass transistors switch on and the input charge is integrated by the high-energy amplifier. The signal is shaped and stored by a peak-hold, then read out on a multiplexed output. Control logic resets the amplifiers and bypass circuit, allowing the low-energy amplifier to measure the subsequent decay signal. We present simulations and test results, demonstrating the AIDA ASIC operation over a wide range of input signals. (authors)

  9. Integrated circuit amplifiers for multi-electrode intracortical recording.

    Science.gov (United States)

    Jochum, Thomas; Denison, Timothy; Wolf, Patrick

    2009-02-01

    Significant progress has been made in systems that interpret the electrical signals of the brain in order to control an actuator. One version of these systems senses neuronal extracellular action potentials with an array of up to 100 miniature probes inserted into the cortex. The impedance of each probe is high, so environmental electrical noise is readily coupled to the neuronal signal. To minimize this noise, an amplifier is placed close to each probe. Thus, the need has arisen for many amplifiers to be placed near the cortex. Commercially available integrated circuits do not satisfy the area, power and noise requirements of this application, so researchers have designed custom integrated-circuit amplifiers. This paper presents a comprehensive survey of the neural amplifiers described in publications prior to 2008. Methods to achieve high input impedance, low noise and a large time-constant high-pass filter are reviewed. A tutorial on the biological, electrochemical, mechanical and electromagnetic phenomena that influence amplifier design is provided. Areas for additional research, including sub-nanoampere electrolysis and chronic cortical heating, are discussed. Unresolved design concerns, including teraohm circuitry, electrical overstress and component failure, are identified.

  10. Series-Tuned High Efficiency RF-Power Amplifiers

    DEFF Research Database (Denmark)

    Vidkjær, Jens

    2008-01-01

    An approach to high efficiency RF-power amplifier design is presented. It addresses simultaneously efficiency optimization and peak voltage limitations when transistors are pushed towards their power limits.......An approach to high efficiency RF-power amplifier design is presented. It addresses simultaneously efficiency optimization and peak voltage limitations when transistors are pushed towards their power limits....

  11. Functional Blocks and Biquadratic ARC Filters using Transimpedance Amplifiers

    Directory of Open Access Journals (Sweden)

    R. Sarman

    1997-04-01

    Full Text Available The aims of the article are design and analysis of modern circuits including high performance functional blocks and biquadratic filters using transimpedance amplifiers. Here are given various types of these circuits, that works in classical voltage, current or hybrid mode. In this paper are also compared various possibilities of connection of single amplifier filters as for reduction of influence of transimpedance amplifier parasitic elements.

  12. Functional Blocks and Biquadratic ARC Filters using Transimpedance Amplifiers

    OpenAIRE

    R. Sarman; R. Prokop; T. Dostal

    1997-01-01

    The aims of the article are design and analysis of modern circuits including high performance functional blocks and biquadratic filters using transimpedance amplifiers. Here are given various types of these circuits, that works in classical voltage, current or hybrid mode. In this paper are also compared various possibilities of connection of single amplifier filters as for reduction of influence of transimpedance amplifier parasitic elements.

  13. Using MEMS Capacitive Switches in Tunable RF Amplifiers

    OpenAIRE

    Danson John; Plett Calvin; Tait Niall

    2006-01-01

    A MEMS capacitive switch suitable for use in tunable RF amplifiers is described. A MEMS switch is designed, fabricated, and characterized with physical and RF measurements for inclusion in simulations. Using the MEMS switch models, a dual-band low-noise amplifier (LNA) operating at GHz and GHz, and a tunable power amplifier (PA) at GHz are simulated in m CMOS. MEMS switches allow the LNA to operate with 11 dB of isolation between the two bands while maintaining dB of gain and sub- dB no...

  14. Cone Beam Computed Tomography-based Evaluation of the Anterior Teeth Position Changes obtained by Passive Self-ligating Brackets.

    Science.gov (United States)

    Rhoden, Fernando K; Maltagliati, Liliana Á; de Castro Ferreira Conti, Ana C; Almeida-Pedrin, Renata R; Filho, Leopoldino C; de Almeida Cardoso, Maurício

    2016-08-01

    The objective of this study was to evaluate the anterior teeth position changes obtained by passive self-ligating brackets using cone beam computed tomography (CBCT). Twenty patients with a mean age of 16.5 years, class I malocclusion, constricted maxillary arch, and teeth crowding above 5 mm were enrolled in this study, and treated by passive orthodontic self-ligating brackets. A sequence of stainless steel thermoset wire was implemented with ending wire of 0.019" × 0.025". The CBCT and dental casts were obtained prior to the installation of orthodontic appliances (T1), and 30 days after rectangular steel wire 0.019" × 0.025" installation (T2). The measurements in CBCT were performed with the Anatomage software, and the dental casts were evaluated with a digital caliper rule with an accuracy of 0.01 mm. The CBCT data demonstrated mean buccal inclination of the upper and lower central incisors ranging from 6.55° to 7.24° respectively. The upper and lower lateral incisors ranged from 4.90° to 8.72° respectively. The lower canines showed an average increase of 3.88° in the buccal inclination and 1.96 mm in the transverse intercuspal distance. The upper canines showed a negative inclination with mean average of -0.36°, and an average increase of 0.82 mm in the transverse distance, with negative correlation with the initial crowding. Treatment with passive self-ligating brackets without obtaining spaces increases buccal inclination of the upper and lower incisors with no correlation with the amount of initial teeth crowding. The intercanine distance tends to a small increase showing different inclinations between the arches. When taking into account the self-ligating brackets, the amount of initial dental crowding is not a limitation factor that could increase the buccal inclination of the anterior teeth.

  15. Criterion of transverse coherence of self-amplified spontaneous emission in high gain free electron laser amplifiers

    International Nuclear Information System (INIS)

    Xie, M.; Kim, K.J.

    1995-01-01

    In a high gain free electron laser amplifier based on Self-Amplified Spontaneous Emission (SASE) the spontaneous radiation generated by an electron beam near the undulator entrance is amplified many orders of magnitude along the undulator. The transverse coherence properties of the amplified radiation depends on both the amplification process and the coherence of the seed radiation (the undulator radiation generated in the first gain length or so). The evolution of the transverse coherence in the amplification process is studied based on the solution of the coupled Maxwell-Vlasov equations including higher order transverse modes. The coherence of the seed radiation is determined by the number of coherent modes in the phase space area of the undulator radiation. We discuss the criterion of transverse coherence and identify governing parameters over a broad range of parameters. In particular we re-examine the well known emittance criterion for the undulator radiation, which states that full transverse coherence is guaranteed if the rms emittance is smaller than the wavelength divided by 4π. It is found that this criterion is modified for SASE because of the different optimization conditions required for the electron beam. Our analysis is a generalization of the previous study by Yu and Krinsky for the case of vanishing emittance with parallel electron beam. Understanding the transverse coherence of SASE is important for the X-ray free electron laser projects now under consideration at SLAC and DESY

  16. An accurate method for quantifying and analyzing copy number variation in porcine KIT by an oligonucleotide ligation assay

    Directory of Open Access Journals (Sweden)

    Cho In-Cheol

    2007-11-01

    Full Text Available Abstract Background Aside from single nucleotide polymorphisms, copy number variations (CNVs are the most important factors in susceptibility to genetic disorders because they affect expression levels of genes. In previous studies, pyrosequencing, mini-sequencing, real-time PCR, invader assays and other techniques have been used to detect CNVs. However, the higher the copy number in a genome, the more difficult it is to resolve the copies, so a more accurate method for measuring CNVs and assigning genotype is needed. Results PCR followed by a quantitative oligonucleotide ligation assay (qOLA was developed for quantifying CNVs. The accuracy and precision of the assay were evaluated for porcine KIT, which was selected as a model locus. Overall, the root mean squares of bias and standard deviation of qOLA were 2.09 and 0.45, respectively. These values are less than half of those in the published pyrosequencing assay for analyzing CNV in porcine KIT. Using a combined method of qOLA and another pyrosequencing for quantitative analysis of KIT copies with spliced forms, we confirmed the segregation of KIT alleles in 145 F1 animals with pedigree information and verified the correct assignment of genotypes. In a diagnostic test on 100 randomly sampled commercial pigs, there was perfect agreement between the genotypes obtained by grouping observations on a scatter plot and by clustering using the nearest centroid sorting method implemented in PROC FASTCLUS of the SAS package. In a test on 159 Large White pigs, there were only two discrepancies between genotypes assigned by the two clustering methods (98.7% agreement, confirming that the quantitative ligation assay established here makes genotyping possible through the accurate measurement of high KIT copy numbers (>4 per diploid genome. Moreover, the assay is sensitive enough for use on DNA from hair follicles, indicating that DNA from various sources could be used. Conclusion We have established a high

  17. Development of resistance to serotonin-induced itch in bile duct ligated mice.

    Science.gov (United States)

    Ostadhadi, Sattar; Haddadi, Nazgol-Sadat; Foroutan, Arash; Azimi, Ehsan; Elmariah, Sarina; Dehpour, Ahmad-Reza

    2017-06-01

    Cholestatic itch can be severe and significantly impair the quality of life of patients. The serotonin system is implicated in cholestatic itch; however, the pruritogenic properties of serotonin have not been evaluated in cholestatic mice. Here, we investigated the serotonin-induced itch in cholestatic mice which was induced by bile duct ligation (BDL). Serotonin, sertraline or saline were administered intradermally to the rostral back area in BDL and sham operated (SHAM) mice, and the scratching behaviour was videotaped for 1 hour. Bile duct ligated mice had significantly increased scratching responses to saline injection on the seventh day after surgery. Additionally, serotonin or sertraline significantly induced scratching behaviour in BDL mice compared to saline at day 7 after surgery, while it did not induce itch at day 5. The scratching behaviour induced by serotonin or sertraline was significantly less in BDL mice compared to SHAM mice. Likewise, the locomotor activity of BDL or SHAM mice was not significantly different from unoperated (UNOP) mice on the fifth and seventh day, suggesting that the scratching behaviour was not affected by motor dysfunctions. Our data suggest that despite the potentiation of evoked itch, a resistance to serotonin-induced itch is developed in cholestatic mice. © 2017 John Wiley & Sons Australia, Ltd.

  18. Self-amplifying mRNA vaccines.

    Science.gov (United States)

    Brito, Luis A; Kommareddy, Sushma; Maione, Domenico; Uematsu, Yasushi; Giovani, Cinzia; Berlanda Scorza, Francesco; Otten, Gillis R; Yu, Dong; Mandl, Christian W; Mason, Peter W; Dormitzer, Philip R; Ulmer, Jeffrey B; Geall, Andrew J

    2015-01-01

    This chapter provides a brief introduction to nucleic acid-based vaccines and recent research in developing self-amplifying mRNA vaccines. These vaccines promise the flexibility of plasmid DNA vaccines with enhanced immunogenicity and safety. The key to realizing the full potential of these vaccines is efficient delivery of nucleic acid to the cytoplasm of a cell, where it can amplify and express the encoded antigenic protein. The hydrophilicity and strong net negative charge of RNA impedes cellular uptake. To overcome this limitation, electrostatic complexation with cationic lipids or polymers and physical delivery using electroporation or ballistic particles to improve cellular uptake has been evaluated. This chapter highlights the rapid progress made in using nonviral delivery systems for RNA-based vaccines. Initial preclinical testing of self-amplifying mRNA vaccines has shown nonviral delivery to be capable of producing potent and robust innate and adaptive immune responses in small animals and nonhuman primates. Historically, the prospect of developing mRNA vaccines was uncertain due to concerns of mRNA instability and the feasibility of large-scale manufacturing. Today, these issues are no longer perceived as barriers in the widespread implementation of the technology. Currently, nonamplifying mRNA vaccines are under investigation in human clinical trials and can be produced at a sufficient quantity and quality to meet regulatory requirements. If the encouraging preclinical data with self-amplifying mRNA vaccines are matched by equivalently positive immunogenicity, potency, and tolerability in human trials, this platform could establish nucleic acid vaccines as a versatile new tool for human immunization. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Pulsed hydrogen fluoride laser oscillator-amplifier experiments

    International Nuclear Information System (INIS)

    Schott, G.L.

    1975-01-01

    Pulsed HF chemical laser oscillator energies were scaled from millijoules to several kilojoules over the period 1970-1974, reaching approximately 10 J with SF 6 and transverse discharges, and using electron-beam initiation and elemental F 2 above 1000J. This demonstrated scalability to large energy with acceptable electrical efficiency is only one prerequisite for application of this gas laser in fusion; equally important matters are achievement of focusable, approximately 1 ns pulses, couplable to light-element targets, all from an affordable system. Exploratory MOPA experiments are reported which address control of HF laser beam focusability and pulse duration, using SF 6 -based experimental oscillator--amplifier sequences and Pockels' cell switching. Simultaneous multiline lasing with 2.6 less than or equal to lambda less than or equal to 3.1 μm and high specific gain and energy density are particularly important factors encountered with HF, where amplifier pumping and lasing occur in a substantially cw temporal relationship, even in less than 100 ns bursts. Time-resolved SF 6 --HI oscillator spectra contain 27 simultaneous lines from six vibrational bands. An apertured, SF 6 -hydrocarbon pin-discharge oscillator generates approximately 10 mJ of TEM 00 radiation, which is amplified to approximately 1 J in approximately 150 ns by a TEA amplifier and p []opagated tens of meters. A three-stage system coupling these elements through an approximately 1 ns electrooptic gate to a greater than 10 J, e-beam energized amplifier is under development. (auth)

  20. Novel matched amplifiers with low noise positive feedback. Part II: Resistive-capacitive feedback

    Science.gov (United States)

    Bruck, Y.; Zakharenko, V.

    2010-02-01

    This article is a continuation of consideration for an amplifier with resistive positive feedback (RPF) (Bruck (2008), 'Novel Matched LNA with Low Noise Positive Feedback. Part 1: General Features and Resistive Feedback', International Journal of Electronics, 95, 441-456). We propose here new configuration schematics of a transformer-less selective LNA with resistive-capacitive positive feedback (RCPF). A circuit of an amplifier with a transistor connected into a circuit with a common base (CB) configuration is analysed in detail. RCPF and RPF circuits are compared. It is shown that the LNA RCPF provides any pass-band, a good level of input and output matching, a minimum noise temperature which is significantly lower than that of the LNA RPF, a rather high linearity, and stability of amplification. The simulation results and some experimental data for the amplifiers intended for use in the LOFAR radiotelescope (Konovalenko et al. (2003), 'Thirty Element Array Antenna as a Prototype of a Huge Low-Frequency Radio Telescope,' Experimental Astronomy, 16, 149-164; Konovalenko (2007), 'Ukrainian Contribution to LOFAR', A scientific workshop, organised by LOFAR/ASTRON' Emmen, Netherlands, 23-27. http://www.lofar.org/workshop) are given. It is assumed that such devices are of a special interest for high-frequency integral circuits (IC).